Optimisation of wavelength modulated Raman spectroscopy: towards high throughput cell screening.
Praveen, Bavishna B; Mazilu, Michael; Marchington, Robert F; Herrington, C Simon; Riches, Andrew; Dholakia, Kishan
2013-01-01
In the field of biomedicine, Raman spectroscopy is a powerful technique to discriminate between normal and cancerous cells. However the strong background signal from the sample and the instrumentation affects the efficiency of this discrimination technique. Wavelength Modulated Raman spectroscopy (WMRS) may suppress the background from the Raman spectra. In this study we demonstrate a systematic approach for optimizing the various parameters of WMRS to achieve a reduction in the acquisition time for potential applications such as higher throughput cell screening. The Signal to Noise Ratio (SNR) of the Raman bands depends on the modulation amplitude, time constant and total acquisition time. It was observed that the sampling rate does not influence the signal to noise ratio of the Raman bands if three or more wavelengths are sampled. With these optimised WMRS parameters, we increased the throughput in the binary classification of normal human urothelial cells and bladder cancer cells by reducing the total acquisition time to 6 s which is significantly lower in comparison to previous acquisition times required for the discrimination between similar cell types.
Shewokis, Patricia A; Shariff, Faiz U; Liu, Yichuan; Ayaz, Hasan; Castellanos, Andres; Lind, D Scott
2017-02-01
Using functional near infrared spectroscopy, a noninvasive, optical brain imaging tool that monitors changes in hemodynamics within the prefrontal cortex (PFC), we assessed performance and cognitive effort during the acquisition, retention and transfer of multiple simulated laparoscopic tasks by novice learners within a contextual interference paradigm. Third-year medical students (n = 10) were randomized to either a blocked or random practice schedule. Across 3 days, students performed 108 acquisition trials of 3 laparoscopic tasks on the LapSim ® simulator followed by delayed retention and transfer tests. Performance metrics (Global score, Total time) and hemodynamic responses (total hemoglobin (μm)) were assessed during skill acquisition, retention and transfer. All acquisition tasks resulted in significant practice schedule X trial block interactions for the left medial anterior PFC. During retention and transfer, random performed the skills in less time and had lower total hemoglobin change in the right dorsolateral PFC than blocked. Compared with blocked, random practice resulted in enhanced learning through better performance and less cognitive load for retention and transfer of simulated laparoscopic tasks. Copyright © 2016 Elsevier Inc. All rights reserved.
Accelerated Optical Projection Tomography Applied to In Vivo Imaging of Zebrafish
Correia, Teresa; Yin, Jun; Ramel, Marie-Christine; Andrews, Natalie; Katan, Matilda; Bugeon, Laurence; Dallman, Margaret J.; McGinty, James; Frankel, Paul; French, Paul M. W.; Arridge, Simon
2015-01-01
Optical projection tomography (OPT) provides a non-invasive 3-D imaging modality that can be applied to longitudinal studies of live disease models, including in zebrafish. Current limitations include the requirement of a minimum number of angular projections for reconstruction of reasonable OPT images using filtered back projection (FBP), which is typically several hundred, leading to acquisition times of several minutes. It is highly desirable to decrease the number of required angular projections to decrease both the total acquisition time and the light dose to the sample. This is particularly important to enable longitudinal studies, which involve measurements of the same fish at different time points. In this work, we demonstrate that the use of an iterative algorithm to reconstruct sparsely sampled OPT data sets can provide useful 3-D images with 50 or fewer projections, thereby significantly decreasing the minimum acquisition time and light dose while maintaining image quality. A transgenic zebrafish embryo with fluorescent labelling of the vasculature was imaged to acquire densely sampled (800 projections) and under-sampled data sets of transmitted and fluorescence projection images. The under-sampled OPT data sets were reconstructed using an iterative total variation-based image reconstruction algorithm and compared against FBP reconstructions of the densely sampled data sets. To illustrate the potential for quantitative analysis following rapid OPT data acquisition, a Hessian-based method was applied to automatically segment the reconstructed images to select the vasculature network. Results showed that 3-D images of the zebrafish embryo and its vasculature of sufficient visual quality for quantitative analysis can be reconstructed using the iterative algorithm from only 32 projections—achieving up to 28 times improvement in imaging speed and leading to total acquisition times of a few seconds. PMID:26308086
Code of Federal Regulations, 2014 CFR
2014-01-01
... of determining the aggregate total amount of voting securities, non-corporate interests and assets of...-corporate interests or voting securities the acquisition of which was exempt at the time of acquisition (or... 16 Commercial Practices 1 2014-01-01 2014-01-01 false Aggregation of voting securities, non...
Code of Federal Regulations, 2012 CFR
2012-01-01
... of determining the aggregate total amount of voting securities, non-corporate interests and assets of...-corporate interests or voting securities the acquisition of which was exempt at the time of acquisition (or... 16 Commercial Practices 1 2012-01-01 2012-01-01 false Aggregation of voting securities, non...
Code of Federal Regulations, 2013 CFR
2013-01-01
... of determining the aggregate total amount of voting securities, non-corporate interests and assets of...-corporate interests or voting securities the acquisition of which was exempt at the time of acquisition (or... 16 Commercial Practices 1 2013-01-01 2013-01-01 false Aggregation of voting securities, non...
Automated data acquisition and processing for a Hohlraum reflectometer
NASA Technical Reports Server (NTRS)
Difilippo, Frank; Mirtich, Michael J.
1988-01-01
A computer and data acquisition board were used to automate a Perkin-Elmer Model 13 spectrophotometer with a Hohlraum reflectivity attachment. Additional electronic circuitry was necessary for amplification, filtering, and debouncing. The computer was programmed to calculate spectral emittance from 1.7 to 14.7 micrometers and also total emittance versus temperature. Automation of the Hohlraum reflectometer reduced the time required to determine total emittance versus temperature from about three hours to about 40 minutes.
Li, Xueming; Zheng, Shawn; Agard, David A.; Cheng, Yifan
2015-01-01
Newly developed direct electron detection cameras have a high image output frame rate that enables recording dose fractionated image stacks of frozen hydrated biological samples by electron cryomicroscopy (cryoEM). Such novel image acquisition schemes provide opportunities to analyze cryoEM data in ways that were previously impossible. The file size of a dose fractionated image stack is 20 ~ 60 times larger than that of a single image. Thus, efficient data acquisition and on-the-fly analysis of a large number of dose-fractionated image stacks become a serious challenge to any cryoEM data acquisition system. We have developed a computer-assisted system, named UCSFImage4, for semi-automated cryo-EM image acquisition that implements an asynchronous data acquisition scheme. This facilitates efficient acquisition, on-the-fly motion correction, and CTF analysis of dose fractionated image stacks with a total time of ~60 seconds/exposure. Here we report the technical details and configuration of this system. PMID:26370395
NASA Technical Reports Server (NTRS)
Clukey, Steven J.
1991-01-01
The real time Dynamic Data Acquisition and Processing System (DDAPS) is described which provides the capability for the simultaneous measurement of velocity, density, and total temperature fluctuations. The system of hardware and software is described in context of the wind tunnel environment. The DDAPS replaces both a recording mechanism and a separate data processing system. DDAPS receives input from hot wire anemometers. Amplifiers and filters condition the signals with computer controlled modules. The analog signals are simultaneously digitized and digitally recorded on disk. Automatic acquisition collects necessary calibration and environment data. Hot wire sensitivities are generated and applied to the hot wire data to compute fluctuations. The presentation of the raw and processed data is accomplished on demand. The interface to DDAPS is described along with the internal mechanisms of DDAPS. A summary of operations relevant to the use of the DDAPS is also provided.
NASA Astrophysics Data System (ADS)
Usman, M.; Atkinson, D.; Heathfield, E.; Greil, G.; Schaeffter, T.; Prieto, C.
2015-04-01
Two major challenges in cardiovascular MRI are long scan times due to slow MR acquisition and motion artefacts due to respiratory motion. Recently, a Motion Corrected-Compressed Sensing (MC-CS) technique has been proposed for free breathing 2D dynamic cardiac MRI that addresses these challenges by simultaneously accelerating MR acquisition and correcting for any arbitrary motion in a compressed sensing reconstruction. In this work, the MC-CS framework is combined with parallel imaging for further acceleration, and is termed Motion Corrected Sparse SENSE (MC-SS). Validation of the MC-SS framework is demonstrated in eight volunteers and three patients for left ventricular functional assessment and results are compared with the breath-hold acquisitions as reference. A non-significant difference (P > 0.05) was observed in the volumetric functional measurements (end diastolic volume, end systolic volume, ejection fraction) and myocardial border sharpness values obtained with the proposed and gold standard methods. The proposed method achieves whole heart multi-slice coverage in 2 min under free breathing acquisition eliminating the time needed between breath-holds for instructions and recovery. This results in two-fold speed up of the total acquisition time in comparison to the breath-hold acquisition.
NASA Technical Reports Server (NTRS)
Clukey, Steven J.
1988-01-01
The high speed Dynamic Data Acquisition System (DDAS) is described which provides the capability for the simultaneous measurement of velocity, density, and total temperature fluctuations. The system of hardware and software is described in context of the wind tunnel environment. The DDAS replaces both a recording mechanism and a separate data processing system. The data acquisition and data reduction process has been combined within DDAS. DDAS receives input from hot wires and anemometers, amplifies and filters the signals with computer controlled modules, and converts the analog signals to digital with real-time simultaneous digitization followed by digital recording on disk or tape. Automatic acquisition (either from a computer link to an existing wind tunnel acquisition system, or from data acquisition facilities within DDAS) collects necessary calibration and environment data. The generation of hot wire sensitivities is done in DDAS, as is the application of sensitivities to the hot wire data to generate turbulence quantities. The presentation of the raw and processed data, in terms of root mean square values of velocity, density and temperature, and the processing of the spectral data is accomplished on demand in near-real-time- with DDAS. A comprehensive description of the interface to the DDAS and of the internal mechanisms will be prosented. A summary of operations relevant to the use of the DDAS will be provided.
Manoel, Edison de J; Dantas, Luiz; Gimenez, Roberto; de Oliveira, Dalton Lustosa
2011-10-01
The organization of actions is based on modules in memory as a result of practice, easing the demand of performing more complex actions. If this modularization occurs, the elements of the module must remain invariant in new tasks. To test this hypothesis, 35 children, age 10 yr., practiced a graphic criterion task on a digital tablet and completed a complex graphic task enclosing the previous one. Total movement and pause times to draw the figure indicated skill acquisition. A module was identified by the variability of relative timing, pause time, and sequencing. Total movement to perform the criterion task did not increase significantly when it was embedded in the more complex task. Modularity was evidenced by the stability of relative timing and pause time and sequencing. The spatial position of new elements did not perturb the module, so the grammar of action may still have been forming.
Systolic time interval data acquisition system. Specialized cardiovascular studies
NASA Technical Reports Server (NTRS)
Baker, J. T.
1976-01-01
The development of a data acquisition system for noninvasive measurement of systolic time intervals is described. R-R interval from the ECG determines instantaneous heart rate prior to the beat to be measured. Total electromechanical systole (Q-S2) is measured from the onset of the ECG Q-wave to the onset of the second heart sound (S2). Ejection time (ET or LVET) is measured from the onset of carotid upstroke to the incisure. Pre-ejection period (PEP) is computed by subtracting ET from Q-S2. PEP/ET ratio is computed directly.
NASA Astrophysics Data System (ADS)
Sato-Akaba, Hideo; Fujii, Hirotada; Hirata, Hiroshi
2008-08-01
This article describes a method for reducing the acquisition time in three-dimensional (3D) continuous-wave electron paramagnetic resonance (CW-EPR) imaging. To visualize nitroxyl spin probes, which have a short lifetime in living organisms, the acquisition time for a data set of spectral projections should be shorter than the lifetime of the spin probes. To decrease the total time required for data acquisition, the duration of magnetic field scanning was reduced to 0.5 s. Moreover, the number of projections was decreased by using the concept of a uniform distribution. To demonstrate this faster data acquisition, two kinds of nitroxyl radicals with different decay rates were measured in mice. 3D EPR imaging of 4-hydroxy-2,2,6,6-tetramethylpiperidine-d 17-1- 15N-1-oxyl in mouse head was successfully carried out. 3D EPR imaging of nitroxyl spin probes with a half-life of a few minutes was achieved for the first time in live animals.
Compressed sensing for ultrasound computed tomography.
van Sloun, Ruud; Pandharipande, Ashish; Mischi, Massimo; Demi, Libertario
2015-06-01
Ultrasound computed tomography (UCT) allows the reconstruction of quantitative tissue characteristics, such as speed of sound, mass density, and attenuation. Lowering its acquisition time would be beneficial; however, this is fundamentally limited by the physical time of flight and the number of transmission events. In this letter, we propose a compressed sensing solution for UCT. The adopted measurement scheme is based on compressed acquisitions, with concurrent randomised transmissions in a circular array configuration. Reconstruction of the image is then obtained by combining the born iterative method and total variation minimization, thereby exploiting variation sparsity in the image domain. Evaluation using simulated UCT scattering measurements shows that the proposed transmission scheme performs better than uniform undersampling, and is able to reduce acquisition time by almost one order of magnitude, while maintaining high spatial resolution.
1992-06-01
presents the concept of software Total Quality Management (TQM) which focuses on the entire process of software acquisition, as a partial solution to...software TQM can be applied to software acquisition. Software Development, Software Acquisition, Total Quality management (TQM), Army Tactical Missile
Television as a Talking Picture Book: A Prop for Language Acquisition.
ERIC Educational Resources Information Center
Lemish, Dafna; Rice, Mabel L.
This study provides longitudinal observations of young children's behaviors while viewing television in their own homes, over a time when the children were actively involved in the process of language acquisition. A total of 16 children were observed for a period ranging from 6 to 8 months. At the beginning, their ages ranged from 6 and 1/2 to 29…
Ozaki, Yuichi; Kitabata, Hironori; Tsujioka, Hiroto; Hosokawa, Seiki; Kashiwagi, Manabu; Ishibashi, Kohei; Komukai, Kenichi; Tanimoto, Takashi; Ino, Yasushi; Takarada, Shigeho; Kubo, Takashi; Kimura, Keizo; Tanaka, Atsushi; Hirata, Kumiko; Mizukoshi, Masato; Imanishi, Toshio; Akasaka, Takashi
2012-01-01
Although an intracoronary frequency-domain optical coherence tomography (FD-OCT) system overcomes several limitations of the time-domain OCT (TD-OCT) system, the former requires injection of contrast media for image acquisition. The increased total amount of contrast media for FD-OCT image acquisition may lead to the impairment of renal function. The safety and usefulness of the non-occlusion method with low-molecular-weight dextran L (LMD-L) via a guiding catheter for TD-OCT image acquisition have been reported previously. The aim of the present study was to compare the image quality and quantitative measurements between contrast media and LMD-L for FD-OCT image acquisition in coronary stented lesions. Twenty-two patients with 25 coronary stented lesions were enrolled in this study. FD-OCT was performed with the continuous-flushing method via a guiding catheter. Both contrast media and LMD-L were infused at a rate of 4 ml/s by an autoinjector. With regard to image quality, the prevalence of clear image segments was comparable between contrast media and LMD-L (97.9% vs. 96.5%, P=0.90). Furthermore, excellent correlations were observed between both flushing solutions in terms of minimum lumen area, mean lumen area, and mean stent area. The total volumes of contrast media and of LMD-L needed for OCT image acquisition were similar. FD-OCT image acquisition with LMD-L has the potential to reduce the total amount of contrast media without loss of image quality.
Code of Federal Regulations, 2010 CFR
2010-10-01
... that involve redesign of systems or subsystems. Life-cycle cost means the total cost to the Government... included, at the most appropriate time in the acquisition cycle, in solicitations and resulting contracts...
Code of Federal Regulations, 2012 CFR
2012-10-01
... that involve redesign of systems or subsystems. Life-cycle cost means the total cost to the Government... included, at the most appropriate time in the acquisition cycle, in solicitations and resulting contracts...
Code of Federal Regulations, 2014 CFR
2014-10-01
... that involve redesign of systems or subsystems. Life-cycle cost means the total cost to the Government... included, at the most appropriate time in the acquisition cycle, in solicitations and resulting contracts...
Multiscale Reconstruction for Magnetic Resonance Fingerprinting
Pierre, Eric Y.; Ma, Dan; Chen, Yong; Badve, Chaitra; Griswold, Mark A.
2015-01-01
Purpose To reduce acquisition time needed to obtain reliable parametric maps with Magnetic Resonance Fingerprinting. Methods An iterative-denoising algorithm is initialized by reconstructing the MRF image series at low image resolution. For subsequent iterations, the method enforces pixel-wise fidelity to the best-matching dictionary template then enforces fidelity to the acquired data at slightly higher spatial resolution. After convergence, parametric maps with desirable spatial resolution are obtained through template matching of the final image series. The proposed method was evaluated on phantom and in-vivo data using the highly-undersampled, variable-density spiral trajectory and compared with the original MRF method. The benefits of additional sparsity constraints were also evaluated. When available, gold standard parameter maps were used to quantify the performance of each method. Results The proposed approach allowed convergence to accurate parametric maps with as few as 300 time points of acquisition, as compared to 1000 in the original MRF work. Simultaneous quantification of T1, T2, proton density (PD) and B0 field variations in the brain was achieved in vivo for a 256×256 matrix for a total acquisition time of 10.2s, representing a 3-fold reduction in acquisition time. Conclusions The proposed iterative multiscale reconstruction reliably increases MRF acquisition speed and accuracy. PMID:26132462
Space-time migration patterns and risk of HIV acquisition in rural South Africa
Dobra, Adrian; Bärnighausen, Till; Vandormael, Alain; Tanser, Frank
2017-01-01
Objective: To quantify the space-time dimensions of human mobility in relationship to the risk of HIV acquisition. Methods: We used data from the population cohort located in a high HIV prevalence, rural population in KwaZulu-Natal, South Africa (2000–2014). We geolocated 8006 migration events (representing 1 028 782 km traveled) for 17 743 individuals (≥15 years of age) who were HIV negative at baseline and followed up these individuals for HIV acquisition (70 395 person-years). Based on the complete geolocated residential history of every individual in this cohort, we constructed two detailed time-varying migration indices. We then used interval-censored Cox proportional hazards models to quantify the relationship between the migration indices and the risk of HIV acquisition. Results: In total, 17.4% of participants migrated at least once outside the rural study community during the period of observation (median migration distance = 107.1 km, interquartile range 18.9–387.5). The two migration indices were highly predictive of hazard of HIV acquisition (P < 0.01) in both men and women. Holding other factors equal, the risk of acquiring HIV infection increased by 50% for migration distances of 40 km (men) and 109 km (women). HIV acquisition risk also increased by 50% when participants spent 44% (men) and 90% (women) of their respective time outside the rural study community. Conclusion: This in-depth analysis of a population cohort in a rural sub-Saharan African population has revealed a clear nonlinear relationship between distance migrated and HIV acquisition. Our findings show that even relatively short-distance migration events confer substantial additional risk of acquisition. PMID:27755099
Debatin, Maurice; Hesser, Jürgen
2015-01-01
Reducing the amount of time for data acquisition and reconstruction in industrial CT decreases the operation time of the X-ray machine and therefore increases the sales. This can be achieved by reducing both, the dose and the pulse length of the CT system and the number of projections for the reconstruction, respectively. In this paper, a novel generalized Anisotropic Total Variation regularization for under-sampled, low-dose iterative CT reconstruction is discussed and compared to the standard methods, Total Variation, Adaptive weighted Total Variation and Filtered Backprojection. The novel regularization function uses a priori information about the Gradient Magnitude Distribution of the scanned object for the reconstruction. We provide a general parameterization scheme and evaluate the efficiency of our new algorithm for different noise levels and different number of projection views. When noise is not present, error-free reconstructions are achievable for AwTV and GATV from 40 projections. In cases where noise is simulated, our strategy achieves a Relative Root Mean Square Error that is up to 11 times lower than Total Variation-based and up to 4 times lower than AwTV-based iterative statistical reconstruction (e.g. for a SNR of 223 and 40 projections). To obtain the same reconstruction quality as achieved by Total Variation, the projection number and the pulse length, and the acquisition time and the dose respectively can be reduced by a factor of approximately 3.5, when AwTV is used and a factor of approximately 6.7, when our proposed algorithm is used.
NASA Astrophysics Data System (ADS)
Lucas, G.
2015-08-01
This article overall deals with production time with orthophoto imagery with medium size digital frame camera. The workflow examination follows two main parts: data acquisition and post-processing. The objectives of the research are fourfold: 1/ gathering time references for the most important steps of orthophoto production (it turned out that literature is missing on this topic); these figures are used later for total production time estimation; 2/ identifying levers for reducing orthophoto production time; 3/ building a simplified production workflow for emergency response: less exigent with accuracy and faster; and compare it to a classical workflow; 4/ providing methodical elements for the estimation of production time with a custom project. In the data acquisition part a comprehensive review lists and describes all the factors that may affect the acquisition efficiency. Using a simulation with different variables (average line length, time of the turns, flight speed) their effect on acquisition efficiency is quantitatively examined. Regarding post-processing, the time references figures were collected from the processing of a 1000 frames case study with 15 cm GSD covering a rectangular area of 447 km2; the time required to achieve each step during the production is written down. When several technical options are possible, each one is tested and time documented so as all alternatives are available. Based on a technical choice with the workflow and using the compiled time reference of the elementary steps, a total time is calculated for the post-processing of the 1000 frames. Two scenarios are compared as regards to time and accuracy. The first one follows the "normal" practices, comprising triangulation, orthorectification and advanced mosaicking methods (feature detection, seam line editing and seam applicator); the second is simplified and make compromise over positional accuracy (using direct geo-referencing) and seamlines preparation in order to achieve orthophoto production faster. The shortened workflow reduces the production time by more than three whereas the positional error increases from 1 GSD to 1.5 GSD. The examination of time allocation through the production process shows that it is worth sparing time in the post-processing phase.
Puddington, Martín M; Papini, Mauricio R; Muzio, Rubén N
2018-01-01
Instrumental learning guides behavior toward resources. When such resources are no longer available, approach to previously reinforced locations is reduced, a process called extinction. The present experiments are concerned with factors affecting the extinction of acquired behaviors in toads. In previous experiments, total reward magnitude in acquisition and duration of extinction trials were confounded. The present experiments were designed to test the effects of these factors in factorial designs. Experiment 1 varied reward magnitude (900, 300, or 100 s of water access per trial) and amount of acquisition training (5 or 15 daily trials). With total amount of water access equated in acquisition, extinction with large rewards was faster (longer latencies in 900/5 than 300/15), but with total amount of training equated, extinction with small rewards was faster (longer latencies in 100/15 than 300/15). Experiment 2 varied reward magnitude (1200 or 120 s of water access per trial) while holding constant the number of acquisition trials (5 daily trials) and the duration of extinction trials (300 s). Extinction performance was lower with small, rather than large reward magnitude (longer latencies in 120/300 than in 1200/300). Thus, instrumental extinction depends upon the amount of time toads are exposed to the empty goal compartment during extinction trials.
Using Modified Fagan Inspections to Control Rapid System Development
NASA Technical Reports Server (NTRS)
Griesel, M. A.; Welz, L. L.
1994-01-01
The Jet Propulsion Laboratory (JPL) has been developing new approaches to software and system development to shorten life cycle time and reduce total life-cycle cost, while maintaining product quality. One such approach has been taken by the Just-In-Time (JIT) Materiel Acquisition System Development Project.
Multiscale reconstruction for MR fingerprinting.
Pierre, Eric Y; Ma, Dan; Chen, Yong; Badve, Chaitra; Griswold, Mark A
2016-06-01
To reduce the acquisition time needed to obtain reliable parametric maps with Magnetic Resonance Fingerprinting. An iterative-denoising algorithm is initialized by reconstructing the MRF image series at low image resolution. For subsequent iterations, the method enforces pixel-wise fidelity to the best-matching dictionary template then enforces fidelity to the acquired data at slightly higher spatial resolution. After convergence, parametric maps with desirable spatial resolution are obtained through template matching of the final image series. The proposed method was evaluated on phantom and in vivo data using the highly undersampled, variable-density spiral trajectory and compared with the original MRF method. The benefits of additional sparsity constraints were also evaluated. When available, gold standard parameter maps were used to quantify the performance of each method. The proposed approach allowed convergence to accurate parametric maps with as few as 300 time points of acquisition, as compared to 1000 in the original MRF work. Simultaneous quantification of T1, T2, proton density (PD), and B0 field variations in the brain was achieved in vivo for a 256 × 256 matrix for a total acquisition time of 10.2 s, representing a three-fold reduction in acquisition time. The proposed iterative multiscale reconstruction reliably increases MRF acquisition speed and accuracy. Magn Reson Med 75:2481-2492, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hodek-Wuerz, Roman; Martin, Jean-Baptiste; Wilhelm, Kai
Percutaneous vertebroplasty (PVP) is carried out under fluoroscopic control in most centers. The exclusion of implant leakage and the assessment of implant distribution might be difficult to assess based on two-dimensional radiographic projection images only. We evaluated the feasibility of performing a follow-up examination after PVP with rotational acquisitions and volumetric reconstructions in the angio suite. Twenty consecutive patients underwent standard PVP procedures under fluoroscopic control. Immediate postprocedure evaluation of the implant distribution in the angio suite (BV 3000; Philips, The Netherlands) was performed using rotational acquisitions (typical parameters for the image acquisition included a 17-cm field-of-view, 200 acquired imagesmore » for a total angular range of 180{sup o}). Postprocessing of acquired volumetric datasets included multiplanar reconstruction (MPR), maximum intensity projection (MIP), and volume rendering technique (VRT) images that were displayed as two-dimensional slabs or as entire three-dimensional volumes. Image evaluation included lesion and implant assessment with special attention given to implant leakage. Findings from rotational acquisitions were compared to findings from postinterventional CT. The time to perform and to postprocess the rotational acquisitions was in all cases less then 10 min. Assessment of implant distribution after PVP using rotational image acquisition methods and volumetric reconstructions was possible in all patients. Cement distribution and potential leakage sites were visualized best on MIP images presented as slabs. From a total of 33 detected leakages with CT, 30 could be correctly detected by rotational image acquisition. Rotational image acquisitions and volumetric reconstruction methods provided a fast method to control radiographically the result of PVP in our cases.« less
Klintwall, Lars; Macari, Suzanne; Eikeseth, Svein; Chawarska, Katarzyna
2015-11-01
Recent studies have suggested that skill acquisition rates for children with autism spectrum disorders receiving early interventions can be predicted by child motivation. We examined whether level of interest during an Autism Diagnostic Observation Schedule assessment at 2 years predicts subsequent rates of verbal, nonverbal, and adaptive skill acquisition to the age of 3 years. A total of 70 toddlers with autism spectrum disorder, mean age of 21.9 months, were scored using Interest Level Scoring for Autism, quantifying toddlers' interest in toys, social routines, and activities that could serve as reinforcers in an intervention. Adaptive level and mental age were measured concurrently (Time 1) and again after a mean of 16.3 months of treatment (Time 2). Interest Level Scoring for Autism score, Autism Diagnostic Observation Schedule score, adaptive age equivalent, verbal and nonverbal mental age, and intensity of intervention were entered into regression models to predict rates of skill acquisition. Interest level at Time 1 predicted subsequent acquisition rate of adaptive skills (R(2) = 0.36) and verbal mental age (R(2) = 0.30), above and beyond the effects of Time 1 verbal and nonverbal mental ages and Autism Diagnostic Observation Schedule scores. Interest level at Time 1 also contributed (R(2) = 0.30), with treatment intensity, to variance in development of nonverbal mental age. © The Author(s) 2014.
Instant images of the human heart using a new, whole-body MR imaging system.
Rzedzian, R R; Pykett, I L
1987-08-01
An extremely rapid MR imaging technique is described, and its use on a new 2.0-T high-speed MR system is demonstrated. This implementation permits complete filling of the two-dimensional spatial-frequency domain (k-space) within an acquisition window of 26 msec. With this acquisition window placed under the spin-echo signal envelope generated by a 90-180 degree pulse pair, the image contrast is the same as that of a conventional spin-echo pulse sequence. Resultant proton images have a motion-independent voxel resolution of 0.08 cm3 and a signal-to-noise ratio for cardiac muscle of approximately 30:1 (for TE = 30 msec) with no signal averaging. The pulse sequence yields images that are chemical shift-resolved. The total proton density distribution is optionally presented with lipid and water signals displayed in two different colors. Cardiac function is observed by displaying multiple images, acquired at different times in successive cardiac periods, in a cyclic movie format. Such motion pictures are obtained within a single period of suspended respiration, thereby assuring freedom from respiratory related motion artifacts. As preliminary examples, we present MR images of the normal adult human heart that have total acquisition times of only 40 msec/image and that show the major cardiac anatomy. Frames from movie loops show contraction of cardiac chambers and left ventricular wall thickening. The extremely rapid acquisition time of this technique suggests that it may hold promise for the routine and cost-effective evaluation of cardiac anatomy and function.
Chen, Ming-Kai; Menard, David H; Cheng, David W
2016-03-01
In pursuit of as-low-as-reasonably-achievable (ALARA) doses, this study investigated the minimal required radioactivity and corresponding imaging time for reliable semiquantification in PET/CT imaging. Using a phantom containing spheres of various diameters (3.4, 2.1, 1.5, 1.2, and 1.0 cm) filled with a fixed (18)F-FDG concentration of 165 kBq/mL and a background concentration of 23.3 kBq/mL, we performed PET/CT at multiple time points over 20 h of radioactive decay. The images were acquired for 10 min at a single bed position for each of 10 half-lives of decay using 3-dimensional list mode and were reconstructed into 1-, 2-, 3-, 4-, 5-, and 10-min acquisitions per bed position using an ordered-subsets expectation maximum algorithm with 24 subsets and 2 iterations and a gaussian 2-mm filter. SUVmax and SUVavg were measured for each sphere. The minimal required activity (±10%) for precise SUVmax semiquantification in the spheres was 1.8 kBq/mL for an acquisition of 10 min, 3.7 kBq/mL for 3-5 min, 7.9 kBq/mL for 2 min, and 17.4 kBq/mL for 1 min. The minimal required activity concentration-acquisition time product per bed position was 10-15 kBq/mL⋅min for reproducible SUV measurements within the spheres without overestimation. Using the total radioactivity and counting rate from the entire phantom, we found that the minimal required total activity-time product was 17 MBq⋅min and the minimal required counting rate-time product was 100 kcps⋅min. Our phantom study determined a threshold for minimal radioactivity and acquisition time for precise semiquantification in (18)F-FDG PET imaging that can serve as a guide in pursuit of achieving ALARA doses. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Accelerated self-gated UTE MRI of the murine heart
NASA Astrophysics Data System (ADS)
Motaal, Abdallah G.; Noorman, Nils; De Graaf, Wolter L.; Florack, Luc J.; Nicolay, Klaas; Strijkers, Gustav J.
2014-03-01
We introduce a new protocol to obtain radial Ultra-Short TE (UTE) MRI Cine of the beating mouse heart within reasonable measurement time. The method is based on a self-gated UTE with golden angle radial acquisition and compressed sensing reconstruction. The stochastic nature of the retrospective triggering acquisition scheme produces an under-sampled and random kt-space filling that allows for compressed sensing reconstruction, hence reducing scan time. As a standard, an intragate multislice FLASH sequence with an acquisition time of 4.5 min per slice was used to produce standard Cine movies of 4 mice hearts with 15 frames per cardiac cycle. The proposed self-gated sequence is used to produce Cine movies with short echo time. The total scan time was 11 min per slice. 6 slices were planned to cover the heart from the base to the apex. 2X, 4X and 6X under-sampled k-spaces cine movies were produced from 2, 1 and 0.7 min data acquisitions for each slice. The accelerated cine movies of the mouse hearts were successfully reconstructed with a compressed sensing algorithm. Compared to the FLASH cine images, the UTE images showed much less flow artifacts due to the short echo time. Besides, the accelerated movies had high image quality and the undersampling artifacts were effectively removed. Left ventricular functional parameters derived from the standard and the accelerated cine movies were nearly identical.
Same Hours, Different Time Distribution: Any Difference in EFL?
ERIC Educational Resources Information Center
Serrano, Raquel; Munoz, Carmen
2007-01-01
The effects of the distribution of instructional time on the acquisition of a second or foreign language are still not well known. This paper will analyze the performance of adult students enrolled in three different types of EFL programs in which the distribution of time varies. The first one, called "extensive", distributes a total of 110 h in 7…
Wald, Lawrence L; Polimeni, Jonathan R
2017-07-01
We review the components of time-series noise in fMRI experiments and the effect of image acquisition parameters on the noise. In addition to helping determine the total amount of signal and noise (and thus temporal SNR), the acquisition parameters have been shown to be critical in determining the ratio of thermal to physiological induced noise components in the time series. Although limited attention has been given to this latter metric, we show that it determines the degree of spatial correlations seen in the time-series noise. The spatially correlations of the physiological noise component are well known, but recent studies have shown that they can lead to a higher than expected false-positive rate in cluster-wise inference based on parametric statistical methods used by many researchers. Based on understanding the effect of acquisition parameters on the noise mixture, we propose several acquisition strategies that might be helpful reducing this elevated false-positive rate, such as moving to high spatial resolution or using highly-accelerated acquisitions where thermal sources dominate. We suggest that the spatial noise correlations at the root of the inflated false-positive rate problem can be limited with these strategies, and the well-behaved spatial auto-correlation functions (ACFs) assumed by the conventional statistical methods are retained if the high resolution data is smoothed to conventional resolutions. Copyright © 2017 Elsevier Inc. All rights reserved.
Zan, Yunlong; Long, Yong; Chen, Kewei; Li, Biao; Huang, Qiu; Gullberg, Grant T
2017-07-01
Our previous works have found that quantitative analysis of 123 I-MIBG kinetics in the rat heart with dynamic single-photon emission computed tomography (SPECT) offers the potential to quantify the innervation integrity at an early stage of left ventricular hypertrophy. However, conventional protocols involving a long acquisition time for dynamic imaging reduce the animal survival rate and thus make longitudinal analysis difficult. The goal of this work was to develop a procedure to reduce the total acquisition time by selecting nonuniform acquisition times for projection views while maintaining the accuracy and precision of estimated physiologic parameters. Taking dynamic cardiac imaging with 123 I-MIBG in rats as an example, we generated time activity curves (TACs) of regions of interest (ROIs) as ground truths based on a direct four-dimensional reconstruction of experimental data acquired from a rotating SPECT camera, where TACs represented as the coefficients of B-spline basis functions were used to estimate compartmental model parameters. By iteratively adjusting the knots (i.e., control points) of B-spline basis functions, new TACs were created according to two rules: accuracy and precision. The accuracy criterion allocates the knots to achieve low relative entropy between the estimated left ventricular blood pool TAC and its ground truth so that the estimated input function approximates its real value and thus the procedure yields an accurate estimate of model parameters. The precision criterion, via the D-optimal method, forces the estimated parameters to be as precise as possible, with minimum variances. Based on the final knots obtained, a new protocol of 30 min was built with a shorter acquisition time that maintained a 5% error in estimating rate constants of the compartment model. This was evaluated through digital simulations. The simulation results showed that our method was able to reduce the acquisition time from 100 to 30 min for the cardiac study of rats with 123 I-MIBG. Compared to a uniform interval dynamic SPECT protocol (1 s acquisition interval, 30 min acquisition time), the newly proposed protocol with nonuniform interval achieved comparable (K1 and k2, P = 0.5745 for K1 and P = 0.0604 for k2) or better (Distribution Volume, DV, P = 0.0004) performance for parameter estimates with less storage and shorter computational time. In this study, a procedure was devised to shorten the acquisition time while maintaining the accuracy and precision of estimated physiologic parameters in dynamic SPECT imaging. The procedure was designed for 123 I-MIBG cardiac imaging in rat studies; however, it has the potential to be extended to other applications, including patient studies involving the acquisition of dynamic SPECT data. © 2017 American Association of Physicists in Medicine.
ERIC Educational Resources Information Center
Ziomek, M. M.; Rehfeldt, R. A.
2008-01-01
This study compared the total amount of training time and total number of trial blocks for individuals with severe developmental disabilities to acquire mands under control of unconditioned establishing operations and mands under control of transitive conditioned establishing operations for manual sign and for the Picture Exchange Communication…
Koulikov, Victoria; Lerman, Hedva; Kesler, Mikhail; Even-Sapir, Einat
2015-12-01
Cadmium zinc telluride (CZT) solid-state detectors have been recently introduced in the field of nuclear medicine in cardiology and breast imaging. The aim of the current study was to evaluate the performance of the novel detectors (CZT) compared to that of the routine NaI(Tl) in bone scintigraphy. A dual-headed CZT-based camera dedicated originally to breast imaging has been used, and in view of the limited size of the detectors, the hands were chosen as the organ for assessment. This is a clinical study. Fifty-eight consecutive patients (total 116 hands) referred for bone scan for suspected hand pathology gave their informed consent to have two acquisitions, using the routine camera and the CZT-based camera. The latter was divided into full-dose full-acquisition time (FD CZT) and reduced-dose short-acquisition time (RD CZT) on CZT technology, so three image sets were available for analysis. Data analysis included comparing the detection of hot lesions and identification of the metacarpophalangeal, proximal interphalangeal, and distal interphalangeal joints. A total of 69 hot lesions were detected on the CZT image sets; of these, 61 were identified as focal sites of uptake on NaI(Tl) data. On FD CZT data, 385 joints were identified compared to 168 on NaI(Tl) data (p < 0.001). There was no statistically significant difference in delineation of joints between FD and RD CZT data as the latter identified 383 joints. Bone scintigraphy using a CZT-based gamma camera is associated with improved lesion detection and anatomic definition. The superior physical characteristics of this technique raised a potential reduction in administered dose and/or acquisition time without compromising image quality.
Papinutto, N.; Schlaeger, R.; Panara, V.; Caverzasi, E.; Ahn, S.; Johnson, K.J.; Zhu, A.H.; Stern, W.A.; Laub, G.; Hauser, S.L.; Henry, R.G.
2018-01-01
PURPOSE In-vivo assessment of spinal cord gray matter (GM) and white matter (WM) could become pivotal to study various neurological diseases, but it is challenging because of insufficient GM/WM contrast provided by conventional MRI. Here we present and assess a procedure for measurement of spinal cord total cross-sectional area (TCA) and GM areas based on phase sensitive inversion recovery imaging (PSIR). MATERIALS AND METHODS We acquired 2D PSIR images at 3T at each disc level of the spinal axis on 10 healthy subjects and measured TCA, cord diameters, WM and GM area, and GM area/TCA ratio. We secondly investigated 32 healthy subjects at 4 selected levels (C2–C3, C3–C4, T8–T9, T9–T10, total acquisition time <8 minutes) and generated normative reference values of TCA and GM areas. We assessed test-retest, intra- and inter-operator reliability of the acquisition strategy and measurement steps. RESULTS The measurement procedure based on 2D PSIR imaging allowed TCA and GM area assessments along the entire spinal cord axis. The tests we performed revealed high test-retest/intra-operator reliability (mean coefficient of variation (COV) at C2–C3: TCA=0.41%, GM area=2.75%) and inter-operator reliability of the measurements (mean COV on the 4 levels: TCA=0.44%, GM area= 4.20%; mean intra-class correlation coefficient: TCA=0.998, GM area=0.906). CONCLUSION 2D PSIR allows reliable in-vivo assessment of spinal cord TCA, GM and WM areas in clinically feasible acquisition times. The area measurements presented here are in agreement with previous MRI and post-mortem studies. PMID:25483607
Tretriluxana, Jarugool; Runnarong, Nuttakarn; Tretriluxana, Suradej; Prayoonwiwat, Naraporn; Vachalathiti, Roongtiwa; Winstein, Carolee
2013-01-01
Skill acquisition, capacity building, and motivational enhancements are the basis of the Accelerated Skill Acquisition Program (ASAP) and form the foundation for effective incorporation of the paretic upper extremity into life activities. This is the first phase I trial to deliver ASAP during the postacute interval in mildly to moderately impaired stroke survivors and to include an assessment of paretic reach-to-grasp (RTG) coordination using RTG task and cross-correlation analyses. Two baseline and posttreatment evaluations consisted of RTG actions, the Wolf Motor Function Test (WMFT), and the Stroke Impact Scale (SIS). An individualized arm therapy program using ASAP principles was administered for a total of 30 hours, 2 hours per day, for 2 to 4 days per week over 5 weeks. Dependent measures were kinematics of RTG actions, RTG coordination, total time score of WMFT, and stroke recovery score of SIS. All participants tolerated ASAP well, and none reported any adverse effects during or after the protocol. When the 2 baseline evaluations were compared, there were no changes in any RTG kinematics or RTG coordination. In contrast, after 30 hours of ASAP, total movement time and deceleration time of RTG actions markedly decreased, maximum reach (transport) velocity strikingly increased, and time of maximum aperture was accomplished later. Additionally, the maximal RTG correlation coefficient increased with a shorter associated time lag. A similar pattern was observed for the clinical outcome measures of WMFT and SIS. The findings demonstrate the feasibility of using an ASAP protocol for patients 1 to 3 months post stroke. Under ASAP, WMFT tasks and RTG actions were performed faster with higher peak transport velocity and a more coordinated RTG pattern. The next step is to determine whether the immediate gains in the skilled RTG actions persist 6 months alter.
Photoacoustic Imaging of Animals with an Annular Transducer Array
NASA Astrophysics Data System (ADS)
Yang, Di-Wu; Zhou, Zhi-Bin; Zeng, Lv-Ming; Zhou, Xin; Chen, Xing-Hui
2014-07-01
A photoacoustic system with an annular transducer array is presented for rapid, high-resolution photoacoustic tomography of animals. An eight-channel data acquisition system is applied to capture the photoacoustic signals by using multiplexing and the total time of data acquisition and transferring is within 3 s. A limited-view filtered back projection algorithm is used to reconstruct the photoacoustic images. Experiments are performed on a mouse head and a rabbit head and clear photoacoustic images are obtained. The experimental results demonstrate that this imaging system holds the potential for imaging the human brain.
ERIC Educational Resources Information Center
Drake, James Bob
1981-01-01
From results on the tensile strength and nick-break average jury evaluations test, it was concluded that with the same total practice time, different distributions of welding practice time intervals (15, 30, and 45 minutes) influence the quality of butt welds made by ninth-grade vocational agriculture students. (Author/SJL)
Schnell, Lauren K; Vladescu, Jason C; Kodak, Tiffany; Nottingham, Casey L
2018-06-17
Generalization is a critical outcome for individuals with autism spectrum disorder (ASD) who display new skills in a limited range of contexts. In the absence of proper planning, generalization may not be observed. The purpose of the current study was to directly compare serial to concurrent multiple exemplar training using total training time per exemplar, mean total training time, and exposures to mastery across three children diagnosed with ASD. Additionally, we assessed the efficiency of presenting secondary targets in the antecedent and consequence portions of learning trials and evaluated generalization to tacts not associated with direct teaching. Results suggested that all training conditions produced acquisition and generalization for trained and untrained exemplars. However, the serial multiple exemplar training condition was more efficient for two participants, whereas the instructive feedback condition was the most efficient for the third. Findings are discussed considering previous studies and areas for future research. © 2018 Society for the Experimental Analysis of Behavior.
Gaitanis, Anastasios; Kastis, George A; Vlastou, Elena; Bouziotis, Penelope; Verginis, Panayotis; Anagnostopoulos, Constantinos D
2017-08-01
The Tera-Tomo 3D image reconstruction algorithm (a version of OSEM), provided with the Mediso nanoScan® PC (PET8/2) small-animal positron emission tomograph (PET)/x-ray computed tomography (CT) scanner, has various parameter options such as total level of regularization, subsets, and iterations. Also, the acquisition time in PET plays an important role. This study aims to assess the performance of this new small-animal PET/CT scanner for different acquisition times and reconstruction parameters, for 2-deoxy-2-[ 18 F]fluoro-D-glucose ([ 18 F]FDG) and Ga-68, under the NEMA NU 4-2008 standards. Various image quality metrics were calculated for different realizations of [ 18 F]FDG and Ga-68 filled image quality (IQ) phantoms. [ 18 F]FDG imaging produced improved images over Ga-68. The best compromise for the optimization of all image quality factors is achieved for at least 30 min acquisition and image reconstruction with 52 iteration updates combined with a high regularization level. A high regularization level at 52 iteration updates and 30 min acquisition time were found to optimize most of the figures of merit investigated.
Morsbach, F; Gordic, S; Gruner, C; Niemann, M; Goetti, R; Gotschy, A; Kozerke, S; Alkadhi, H; Manka, R
2016-08-15
This study aims to determine whether the quantification of myocardial fibrosis in patients with Fabry disease (FD) and hypertrophic cardiomyopathy (HCM) using a late gadolinium enhancement (LGE) singlebreath-hold three-dimensional (3D) inversion recovery magnetic resonance (MR) imaging sequence is comparable with a clinically established two-dimensional (2D) multi-breath-hold sequence. In this retrospective, IRB-approved study, 40 consecutive patients (18 male; mean age 50±17years) with Fabry disease (n=18) and HCM (n=22) underwent MR imaging at 1.5T. Spatial resolution was the same for 3D and 2D images (field-of-view, 350×350mm(2); in-plane-resolution, 1.2×1.2mm(2); section-thickness, 8mm). Datasets were analyzed for subjective image quality; myocardial and fibrotic mass, and total fibrotic tissue percentage were quantified. There was no significant difference in subjective image quality between 3D and 2D acquisitions (P=0.1 and P=0.3) for either disease. In patients with Fabry disease there were no significant differences between 3D and 2D acquisitions for myocardial mass (P=0.55), fibrous tissue mass (P=0.89), and total fibrous percentage (P=0.67), with good agreement between acquisitions according to Bland-Altman analyses. In patients with HCM there were also no significant differences between acquisitions for myocardial mass (P=0.48), fibrous tissue mass (P=0.56), and total fibrous percentage (P=0.67), with good agreement according to Bland-Altman analyses. Acquisition time was significantly shorter for 3D (25±5s) as compared to the 2D sequence (349±62s, P<0.001). In patients with Fabry disease and HCM, 3D LGE imaging provides equivalent diagnostic information in regard to quantification of myocardial fibrosis as compared with a standard 2D sequence, but at superior acquisition speed. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
CHARACTERIZATION OF CHROMIUM-CONTAMINATED SOILS USING FIELD-PORTABLE X-RAY FLUORESCENCE
A detailed characterization of the underlying and adjacent soils near a chrome plating shop utilized field-portable X- ray fluorescence (XRF) as a screening tool. XRF permitted real-time acquisition of estimates for total metal content of soils. A trailer-mounted soil coring unit...
Computed Tomography Scanner Productivity and Entry-Level Models in the Global Market
Almeida, R. M. V. R.
2017-01-01
Objective This study evaluated the productivity of computed tomography (CT) models and characterized their simplest (entry-level) models' supply in the world market. Methods CT exam times were measured in eight health facilities in the state of Rio de Janeiro, Brazil. Exams were divided into six stages: (1) arrival of patient records to the examination room; (2) patient arrival; (3) patient positioning; (4) data input prior to exam; (5) image acquisition; and (6) patient departure. CT exam productivity was calculated by dividing the total weekly working time by the total exam time for each model. Additionally, an internet search identified full-body CT manufacturers and their offered entry-level models. Results The time durations of 111 CT exams were obtained. Differences among average exam times were not large, and they were mainly due to stages not directly related to data acquisition or image reconstruction. The survey identified that most manufacturers offer 2- to 4-slice models for Asia, South America, and Africa, and one offers single-slice models (Asia). In the USA, two manufacturers offer models below 16-slice. Conclusion Productivity gains are not linearly related to “slice” number. It is suggested that the use of “shareable platforms” could make CTs cheaper, increasing their availability. PMID:29093804
Five-Hole Flow Angle Probe Calibration for the NASA Glenn Icing Research Tunnel
NASA Technical Reports Server (NTRS)
Gonsalez, Jose C.; Arrington, E. Allen
1999-01-01
A spring 1997 test section calibration program is scheduled for the NASA Glenn Research Center Icing Research Tunnel following the installation of new water injecting spray bars. A set of new five-hole flow angle pressure probes was fabricated to properly calibrate the test section for total pressure, static pressure, and flow angle. The probes have nine pressure ports: five total pressure ports on a hemispherical head and four static pressure ports located 14.7 diameters downstream of the head. The probes were calibrated in the NASA Glenn 3.5-in.-diameter free-jet calibration facility. After completing calibration data acquisition for two probes, two data prediction models were evaluated. Prediction errors from a linear discrete model proved to be no worse than those from a full third-order multiple regression model. The linear discrete model only required calibration data acquisition according to an abridged test matrix, thus saving considerable time and financial resources over the multiple regression model that required calibration data acquisition according to a more extensive test matrix. Uncertainties in calibration coefficients and predicted values of flow angle, total pressure, static pressure. Mach number. and velocity were examined. These uncertainties consider the instrumentation that will be available in the Icing Research Tunnel for future test section calibration testing.
48 CFR 919.502-2 - Total small business set-asides.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 5 2013-10-01 2013-10-01 false Total small business set-asides. 919.502-2 Section 919.502-2 Federal Acquisition Regulations System DEPARTMENT OF ENERGY SOCIOECONOMIC PROGRAMS SMALL BUSINESS PROGRAMS Set-Asides for Small Business 919.502-2 Total small business set...
48 CFR 919.502-2 - Total small business set-asides.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Total small business set-asides. 919.502-2 Section 919.502-2 Federal Acquisition Regulations System DEPARTMENT OF ENERGY SOCIOECONOMIC PROGRAMS SMALL BUSINESS PROGRAMS Set-Asides for Small Business 919.502-2 Total small business set...
48 CFR 919.502-2 - Total small business set-asides.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 5 2012-10-01 2012-10-01 false Total small business set-asides. 919.502-2 Section 919.502-2 Federal Acquisition Regulations System DEPARTMENT OF ENERGY SOCIOECONOMIC PROGRAMS SMALL BUSINESS PROGRAMS Set-Asides for Small Business 919.502-2 Total small business set...
48 CFR 919.502-2 - Total small business set-asides.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Total small business set-asides. 919.502-2 Section 919.502-2 Federal Acquisition Regulations System DEPARTMENT OF ENERGY SOCIOECONOMIC PROGRAMS SMALL BUSINESS PROGRAMS Set-Asides for Small Business 919.502-2 Total small business set...
Oddstig, Jenny; Hedeer, Fredrik; Jögi, Jonas; Carlsson, Marcus; Hindorf, Cecilia; Engblom, Henrik
2013-02-01
For a 1-day myocardial perfusion SPECT (MPS) the recommendations for administered activity stated in the EANM guidelines results in an effective dose of up to 16 mSv per patient. Recently, a gamma camera system, based on cadmium zinc telluride (CZT) technology, was introduced. This technique has the potential to reduce the effective dose and scan time compared to the conventional NaI gamma camera. The aim of this study was to investigate if the effective dose can be reduced with a preserved image quality using CZT technology in MPS. In total, 150 patients were included in the study. All underwent a 1-day (99m)Tc-tetrofosmin stress-rest protocol and were divided into three subgroups (n = 50 in each group) with 4, 3, and 2.5 MBq/kg body weight of administered activity in the stress examination, respectively. The acquisition time was increased in proportion to the decrease in administered activity. All examinations were analyzed for image quality by visual grading on a 4-point scale (1 = poor, 2 = adequate, 3 = good, 4 = excellent), by two expert readers. The total effective dose (stress + rest) decreased from 9.3 to 5.8 mSv comparing 4 to 2.5 MBq/kg body weight. For the patients undergoing stress examination only (35%) the effective dose, administrating 2.5 MBq/kg, was 1.4 mSv. The image acquisition times for 2.5 MBq/kg body weight were 475 and 300 seconds (stress and rest) compared to 900 seconds for each when using conventional MPS. The average image quality was 3.7 ± 0.5, 3.8 ± 0.5, and 3.8 ± 0.4 for the stress images and 3.5 ± 0.6, 3.6 ± 0.6, and 3.5 ± 0.6 for the rest images and showed no statistically significant difference (P = .62) among the 4, 3, and 2.5 MBq/kg groups. The new CZT technology can be used to considerably decrease the effective dose and acquisition time for MPS with preserved high image quality.
Isolated effects of number of acquisition trials on extinction of rat conditioned approach behavior.
Gottlieb, Daniel A; Prince, Emily B
2012-05-01
Four conditioned approach experiments with rats assessed for effects of number of acquisition trials on extinction of conditioned responding, when number of acquisition sessions and total acquisition time were held constant. In Experiment 1, 32 trials per acquisition session led to more extinction responding than did 1 or 2 trials per session but less than did 4 trials per session. In Experiment 2, 2 trials per acquisition session led to more spontaneous recovery than did 32 trials per session. These latter findings are reminiscent of the overtraining extinction effect (OEE). Experiment 3 attempted to reduce the OEE with a preconditioning phase of partial reinforcement. Experiment 4 attempted to reduce the beneficial within-subject effects of increasing the number of acquisition trials on extinction observed by Gottlieb and Rescorla (2010) by extinguishing stimuli in different sessions. Overall, results suggest a procedural asymmetry: between-subject, increasing the number of trials between any pair of trials does not lead to greater persistence of responding during extinction; within-subject, it does. Results are discussed from an associative perspective, with a focus on explanations involving either frustration or comparator mechanisms, and from an information processing perspective, with a focus on Rate Estimation Theory. Copyright © 2012. Published by Elsevier B.V.
Investigating brain response to music: a comparison of different fMRI acquisition schemes.
Mueller, Karsten; Mildner, Toralf; Fritz, Thomas; Lepsien, Jöran; Schwarzbauer, Christian; Schroeter, Matthias L; Möller, Harald E
2011-01-01
Functional magnetic resonance imaging (fMRI) in auditory experiments is a challenge, because the scanning procedure produces considerable noise that can interfere with the auditory paradigm. The noise might either mask the auditory material presented, or interfere with stimuli designed to evoke emotions because it sounds loud and rather unpleasant. Therefore, scanning paradigms that allow interleaved auditory stimulation and image acquisition appear to be advantageous. The sparse temporal sampling (STS) technique uses a very long repetition time in order to achieve a stimulus presentation in the absence of scanner noise. Although only relatively few volumes are acquired for the resulting data sets, there have been recent studies where this method has furthered remarkable results. A new development is the interleaved silent steady state (ISSS) technique. Compared with STS, this method is capable of acquiring several volumes in the time frame between the auditory trials (while the magnetization is kept in a steady state during stimulus presentation). In order to draw conclusions about the optimum fMRI procedure with auditory stimulation, different echo-planar imaging (EPI) acquisition schemes were compared: Continuous scanning, STS, and ISSS. The total acquisition time of each sequence was adjusted to about 12.5 min. The results indicate that the ISSS approach exhibits the highest sensitivity in detecting subtle activity in sub-cortical brain regions. Copyright © 2010 Elsevier Inc. All rights reserved.
Totally Integrated Munitions Enterprise ''Affordable Munitions Production for the 21st Century''
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burleson, R.R.; Poggio, M.E.; Rosenberg, S.J.
2000-09-13
The U.S. Army faces several munitions manufacturing issues: downsizing of the organic production base, timely fielding of affordable smart munitions, and munitions replenishment during national emergencies. Totally Integrated Munitions Enterprise (TIME) is addressing these complex issues via the development and demonstration of an integrated enterprise. The enterprise will include the tools, network, and open modular architecture controllers to enable accelerated acquisition, shortened concept to volume production, lower life cycle costs, capture of critical manufacturing processes, and communication of process parameters between remote sites to rapidly spin-off production for replenishment by commercial sources. TIME addresses the enterprise as a system, integratingmore » design, engineering, manufacturing, administration, and logistics.« less
Totally Integrated Munitions Enterprise ''Affordable Munitions Production for the 21st Century''
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burleson, R.R.; Poggio, M.E.; Rosenberg, S.J.
2000-08-18
The U.S. Army faces several munitions manufacturing issues: downsizing of the organic production base, timely fielding of affordable smart munitions, and munitions replenishment during national emergencies. Totally Integrated Munitions Enterprise (TIME) is addressing these complex issues via the development and demonstration of an integrated enterprise. The enterprise will include the tools, network, and open modular architecture controllers to enable accelerated acquisition, shortened concept to volume production, lower life cycle costs, capture of critical manufacturing processes, and communication of process parameters between remote sites to rapidly spin-off production for replenishment by commercial sources. TIME addresses the enterprise as a system, integratingmore » design, engineering, manufacturing, administration, and logistics.« less
48 CFR 2052.216-70 - Level of effort.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Level of effort. 2052.216... Level of effort. As prescribed at 2016.307-70(a) the contracting officer shall insert the following..., time and materials, or labor hours basis. Level of Effort (JAN 1993) The NRC's estimate of the total...
NASA Astrophysics Data System (ADS)
Mickevicius, Nikolai J.; Paulson, Eric S.
2017-04-01
The purpose of this work is to investigate the effects of undersampling and reconstruction algorithm on the total processing time and image quality of respiratory phase-resolved 4D MRI data. Specifically, the goal is to obtain quality 4D-MRI data with a combined acquisition and reconstruction time of five minutes or less, which we reasoned would be satisfactory for pre-treatment 4D-MRI in online MRI-gRT. A 3D stack-of-stars, self-navigated, 4D-MRI acquisition was used to scan three healthy volunteers at three image resolutions and two scan durations. The NUFFT, CG-SENSE, SPIRiT, and XD-GRASP reconstruction algorithms were used to reconstruct each dataset on a high performance reconstruction computer. The overall image quality, reconstruction time, artifact prevalence, and motion estimates were compared. The CG-SENSE and XD-GRASP reconstructions provided superior image quality over the other algorithms. The combination of a 3D SoS sequence and parallelized reconstruction algorithms using computing hardware more advanced than those typically seen on product MRI scanners, can result in acquisition and reconstruction of high quality respiratory correlated 4D-MRI images in less than five minutes.
Total body photography for skin cancer screening.
Dengel, Lynn T; Petroni, Gina R; Judge, Joshua; Chen, David; Acton, Scott T; Schroen, Anneke T; Slingluff, Craig L
2015-11-01
Total body photography may aid in melanoma screening but is not widely applied due to time and cost. We hypothesized that a near-simultaneous automated skin photo-acquisition system would be acceptable to patients and could rapidly obtain total body images that enable visualization of pigmented skin lesions. From February to May 2009, a study of 20 volunteers was performed at the University of Virginia to test a prototype 16-camera imaging booth built by the research team and to guide development of special purpose software. For each participant, images were obtained before and after marking 10 lesions (five "easy" and five "difficult"), and images were evaluated to estimate visualization rates. Imaging logistical challenges were scored by the operator, and participant opinion was assessed by questionnaire. Average time for image capture was three minutes (range 2-5). All 55 "easy" lesions were visualized (sensitivity 100%, 90% CI 95-100%), and 54/55 "difficult" lesions were visualized (sensitivity 98%, 90% CI 92-100%). Operators and patients graded the imaging process favorably, with challenges identified regarding lighting and positioning. Rapid-acquisition automated skin photography is feasible with a low-cost system, with excellent lesion visualization and participant acceptance. These data provide a basis for employing this method in clinical melanoma screening. © 2014 The International Society of Dermatology.
Bird community conservation and carbon offsets in western North America.
Schuster, Richard; Martin, Tara G; Arcese, Peter
2014-01-01
Conservation initiatives to protect and restore valued species and communities in human-dominated landscapes face huge challenges linked to the cost of acquiring habitat. We ask how the sale of forest carbon offsets could reduce land acquisition costs, and how the alternate goals of maximizing α or β-diversity in focal communities could affect the prioritization land parcels over a range of conservation targets. Maximizing total carbon storage and carbon sequestration potential reduced land acquisition costs by up to 48%. Maximizing β rather than α-diversity within forest and savannah bird communities reduced acquisition costs by up to 15%, and when these solutions included potential carbon credit revenues, acquisition cost reductions up to 32% were achieved. However, the total cost of conservation networks increased exponentially as area targets increased in all scenarios. Our results indicate that carbon credit sales have the potential to enhance conservation outcomes in human-dominated landscapes by reducing the net acquisition costs of land conservation in old and maturing forests essential for the persistence of old forest plant and animal communities. Maximizing β versus α-diversity may further reduce costs by reducing the total area required to meet conservation targets and enhancing landscape heterogeneity. Although the potential value of carbon credit sales declined as a fraction of total acquisition costs, even conservative scenarios using a carbon credit value of $12.5/T suggest reductions in acquisition cost of up to $235 M, indicating that carbon credit sales could substantially reduce the costs of conservation.
Bird Community Conservation and Carbon Offsets in Western North America
Schuster, Richard; Martin, Tara G.; Arcese, Peter
2014-01-01
Conservation initiatives to protect and restore valued species and communities in human-dominated landscapes face huge challenges linked to the cost of acquiring habitat. We ask how the sale of forest carbon offsets could reduce land acquisition costs, and how the alternate goals of maximizing α or β-diversity in focal communities could affect the prioritization land parcels over a range of conservation targets. Maximizing total carbon storage and carbon sequestration potential reduced land acquisition costs by up to 48%. Maximizing β rather than α-diversity within forest and savannah bird communities reduced acquisition costs by up to 15%, and when these solutions included potential carbon credit revenues, acquisition cost reductions up to 32% were achieved. However, the total cost of conservation networks increased exponentially as area targets increased in all scenarios. Our results indicate that carbon credit sales have the potential to enhance conservation outcomes in human-dominated landscapes by reducing the net acquisition costs of land conservation in old and maturing forests essential for the persistence of old forest plant and animal communities. Maximizing β versus α-diversity may further reduce costs by reducing the total area required to meet conservation targets and enhancing landscape heterogeneity. Although the potential value of carbon credit sales declined as a fraction of total acquisition costs, even conservative scenarios using a carbon credit value of $12.5/T suggest reductions in acquisition cost of up to $235 M, indicating that carbon credit sales could substantially reduce the costs of conservation. PMID:24918621
Evaluation of a High-Resolution Benchtop Micro-CT Scanner for Application in Porous Media Research
NASA Astrophysics Data System (ADS)
Tuller, M.; Vaz, C. M.; Lasso, P. O.; Kulkarni, R.; Ferre, T. A.
2010-12-01
Recent advances in Micro Computed Tomography (MCT) provided the motivation to thoroughly evaluate and optimize scanning, image reconstruction/segmentation and pore-space analysis capabilities of a new generation benchtop MCT scanner and associated software package. To demonstrate applicability to soil research the project was focused on determination of porosities and pore size distributions of two Brazilian Oxisols from segmented MCT-data. Effects of metal filters and various acquisition parameters (e.g. total rotation, rotation step, and radiograph frame averaging) on image quality and acquisition time are evaluated. Impacts of sample size and scanning resolution on CT-derived porosities and pore-size distributions are illustrated.
Noninvasive photoacoustic detecting intraocular foreign bodies with an annular transducer array.
Yang, Diwu; Zeng, Lvming; Pan, Changning; Zhao, Xuehui; Ji, Xuanrong
2013-01-14
We present a fast photoacoustic imaging system based on an annular transducer array for detection of intraocular foreign bodies. An eight-channel data acquisition system is applied to capture the photoacoustic signals using multiplexing and the total time of data acquisition and transferring is within 3 s. A limited-view filtered back projection algorithm is used to reconstruct the photoacoustic images. Experimental models of intraocular metal and glass foreign bodies were constructed on ex vivo pig's eyes and clear photoacoustic images of intraocular foreign bodies were obtained. Experimental results demonstrate the photoacoustic imaging system holds the potential for in clinic detecting the intraocular foreign bodies.
Accelerated 1 H MRSI using randomly undersampled spiral-based k-space trajectories.
Chatnuntawech, Itthi; Gagoski, Borjan; Bilgic, Berkin; Cauley, Stephen F; Setsompop, Kawin; Adalsteinsson, Elfar
2014-07-30
To develop and evaluate the performance of an acquisition and reconstruction method for accelerated MR spectroscopic imaging (MRSI) through undersampling of spiral trajectories. A randomly undersampled spiral acquisition and sensitivity encoding (SENSE) with total variation (TV) regularization, random SENSE+TV, is developed and evaluated on single-slice numerical phantom, in vivo single-slice MRSI, and in vivo three-dimensional (3D)-MRSI at 3 Tesla. Random SENSE+TV was compared with five alternative methods for accelerated MRSI. For the in vivo single-slice MRSI, random SENSE+TV yields up to 2.7 and 2 times reduction in root-mean-square error (RMSE) of reconstructed N-acetyl aspartate (NAA), creatine, and choline maps, compared with the denoised fully sampled and uniformly undersampled SENSE+TV methods with the same acquisition time, respectively. For the in vivo 3D-MRSI, random SENSE+TV yields up to 1.6 times reduction in RMSE, compared with uniform SENSE+TV. Furthermore, by using random SENSE+TV, we have demonstrated on the in vivo single-slice and 3D-MRSI that acceleration factors of 4.5 and 4 are achievable with the same quality as the fully sampled data, as measured by RMSE of reconstructed NAA map, respectively. With the same scan time, random SENSE+TV yields lower RMSEs of metabolite maps than other methods evaluated. Random SENSE+TV achieves up to 4.5-fold acceleration with comparable data quality as the fully sampled acquisition. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.
GPU-accelerated regularized iterative reconstruction for few-view cone beam CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matenine, Dmitri, E-mail: dmitri.matenine.1@ulaval.ca; Goussard, Yves, E-mail: yves.goussard@polymtl.ca; Després, Philippe, E-mail: philippe.despres@phy.ulaval.ca
2015-04-15
Purpose: The present work proposes an iterative reconstruction technique designed for x-ray transmission computed tomography (CT). The main objective is to provide a model-based solution to the cone-beam CT reconstruction problem, yielding accurate low-dose images via few-views acquisitions in clinically acceptable time frames. Methods: The proposed technique combines a modified ordered subsets convex (OSC) algorithm and the total variation minimization (TV) regularization technique and is called OSC-TV. The number of subsets of each OSC iteration follows a reduction pattern in order to ensure the best performance of the regularization method. Considering the high computational cost of the algorithm, it ismore » implemented on a graphics processing unit, using parallelization to accelerate computations. Results: The reconstructions were performed on computer-simulated as well as human pelvic cone-beam CT projection data and image quality was assessed. In terms of convergence and image quality, OSC-TV performs well in reconstruction of low-dose cone-beam CT data obtained via a few-view acquisition protocol. It compares favorably to the few-view TV-regularized projections onto convex sets (POCS-TV) algorithm. It also appears to be a viable alternative to full-dataset filtered backprojection. Execution times are of 1–2 min and are compatible with the typical clinical workflow for nonreal-time applications. Conclusions: Considering the image quality and execution times, this method may be useful for reconstruction of low-dose clinical acquisitions. It may be of particular benefit to patients who undergo multiple acquisitions by reducing the overall imaging radiation dose and associated risks.« less
Skin-Friction Measurements at Subsonic and Transonic Mach Numbers with Embedded-Wire Gages
1981-01-01
Model ................................... 17 9. Boundary-Layer Rake Installation on EBOR Model...boundary-layer total pressure rake eliminates this bulky mechanism and the long data acquisition time, but it introduces interferences which affect the...its construction. Further, boundary-layer rakes are restricted to measurements in thick boundary layers. Surface pressure probes such as Stanton tubes
Kim, Hyungseup; Park, Yunjong; Ko, Youngwoon; Mun, Yeongjin; Lee, Sangmin; Ko, Hyoungho
2018-01-01
Wearable healthcare systems require measurements from electrocardiograms (ECGs) and photoplethysmograms (PPGs), and the blood pressure of the user. The pulse transit time (PTT) can be calculated by measuring the ECG and PPG simultaneously. Continuous-time blood pressure without using an air cuff can be estimated by using the PTT. This paper presents a biosignal acquisition integrated circuit (IC) that can simultaneously measure the ECG and PPG for wearable healthcare applications. Included in this biosignal acquisition circuit are a voltage mode instrumentation amplifier (IA) for ECG acquisition and a current mode transimpedance amplifier for PPG acquisition. The analog outputs from the ECG and PPG channels are muxed and converted to digital signals using 12-bit successive approximation register (SAR) analog-to-digital converter (ADC). The proposed IC is fabricated by using a standard 0.18 μm CMOS process with an active area of 14.44 mm2. The total current consumption for the multichannel IC is 327 μA with a 3.3 V supply. The measured input referred noise of ECG readout channel is 1.3 μVRMS with a bandwidth of 0.5 Hz to 100 Hz. And the measured input referred current noise of the PPG readout channel is 0.122 nA/√Hz with a bandwidth of 0.5 Hz to 100 Hz. The proposed IC, which is implemented using various circuit techniques, can measure ECG and PPG signals simultaneously to calculate the PTT for wearable healthcare applications.
Towards high-resolution 4D flow MRI in the human aorta using kt-GRAPPA and B1+ shimming at 7T.
Schmitter, Sebastian; Schnell, Susanne; Uğurbil, Kâmil; Markl, Michael; Van de Moortele, Pierre-François
2016-08-01
To evaluate the feasibility of aortic 4D flow magnetic resonance imaging (MRI) at 7T with improved spatial resolution using kt-GRAPPA acceleration while restricting acquisition time and to address radiofrequency (RF) excitation heterogeneities with B1+ shimming. 4D flow MRI data were obtained in the aorta of eight subjects using a 16-channel transmit/receive coil array at 7T. Flow quantification and acquisition time were compared for a kt-GRAPPA accelerated (R = 5) and a standard GRAPPA (R = 2) accelerated protocol. The impact of different dynamic B1+ shimming strategies on flow quantification was investigated. Two kt-GRAPPA accelerated protocols with 1.2 × 1.2 × 1.2 mm(3) and 1.8 × 1.8 × 2.4 mm(3) spatial resolution were compared. Using kt-GRAPPA, we achieved a 4.3-fold reduction in net acquisition time resulting in scan times of about 10 minutes. No significant effect on flow quantification was observed compared to standard GRAPPA with R = 2. Optimizing the B1+ fields for the aorta impacted significantly (P < 0.05) the flow quantification while specific B1+ settings were required for respiration navigators. The high-resolution protocol yielded similar flow quantification, but allowed the depiction of branching vessels. 7T in combination with B1+ shimming allows for high-resolution 4D flow MRI acquisitions in the human aorta, while kt-GRAPPA limits total scan times without affecting flow quantification. J. Magn. Reson. Imaging 2016;44:486-499. © 2016 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Tang, Jing; Rahmim, Arman; Lautamäki, Riikka; Lodge, Martin A.; Bengel, Frank M.; Tsui, Benjamin M. W.
2009-05-01
The purpose of this study is to optimize the dynamic Rb-82 cardiac PET acquisition and reconstruction protocols for maximum myocardial perfusion defect detection using realistic simulation data and task-based evaluation. Time activity curves (TACs) of different organs under both rest and stress conditions were extracted from dynamic Rb-82 PET images of five normal patients. Combined SimSET-GATE Monte Carlo simulation was used to generate nearly noise-free cardiac PET data from a time series of 3D NCAT phantoms with organ activities modeling different pre-scan delay times (PDTs) and total acquisition times (TATs). Poisson noise was added to the nearly noise-free projections and the OS-EM algorithm was applied to generate noisy reconstructed images. The channelized Hotelling observer (CHO) with 32× 32 spatial templates corresponding to four octave-wide frequency channels was used to evaluate the images. The area under the ROC curve (AUC) was calculated from the CHO rating data as an index for image quality in terms of myocardial perfusion defect detection. The 0.5 cycle cm-1 Butterworth post-filtering on OS-EM (with 21 subsets) reconstructed images generates the highest AUC values while those from iteration numbers 1 to 4 do not show different AUC values. The optimized PDTs for both rest and stress conditions are found to be close to the cross points of the left ventricular chamber and myocardium TACs, which may promote an individualized PDT for patient data processing and image reconstruction. Shortening the TATs for <~3 min from the clinically employed acquisition time does not affect the myocardial perfusion defect detection significantly for both rest and stress studies.
Goh, Vicky; Halligan, Steve; Hugill, Jo-Ann; Gartner, Louise; Bartram, Clive I
2005-01-01
To determine the effect of acquisition time on quantitative colorectal cancer perfusion measurement. Dynamic contrast-enhanced computed tomography (CT) was performed prospectively in 10 patients with histologically proven colorectal cancer using 4-detector row CT (Lightspeed Plus; GE Healthcare Technologies, Waukesha, WI). Tumor blood flow, blood volume, mean transit time, and permeability were assessed for 3 acquisition times (45, 65, and 130 seconds). Mean values for all 4 perfusion parameters for each acquisition time were compared using the paired t test. Significant differences in permeability values were noted between acquisitions of 45 seconds and 65 and 130 seconds, respectively (P=0.02, P=0.007). There was no significant difference for values of blood volume, blood flow, and mean transit time between any of the acquisition times. Scan acquisitions of 45 seconds are too short for reliable permeability measurement in the abdomen. Longer acquisition times are required.
Partition-based acquisition model for speed up navigated beta-probe surface imaging
NASA Astrophysics Data System (ADS)
Monge, Frédéric; Shakir, Dzhoshkun I.; Navab, Nassir; Jannin, Pierre
2016-03-01
Although gross total resection in low-grade glioma surgery leads to a better patient outcome, the in-vivo control of resection borders remains challenging. For this purpose, navigated beta-probe systems combined with 18F-based radiotracer, relying on activity distribution surface estimation, have been proposed to generate reconstructed images. The clinical relevancy has been outlined by early studies where intraoperative functional information is leveraged although inducing low spatial resolution in reconstruction. To improve reconstruction quality, multiple acquisition models have been proposed. They involve the definition of attenuation matrix for designing radiation detection physics. Yet, they require high computational power for efficient intraoperative use. To address the problem, we propose a new acquisition model called Partition Model (PM) considering an existing model where coefficients of the matrix are taken from a look-up table (LUT). Our model is based upon the division of the LUT into averaged homogeneous values for assigning attenuation coefficients. We validated our model using in vitro datasets, where tumors and peri-tumoral tissues have been simulated. We compared our acquisition model with the o_-the-shelf LUT and the raw method. Acquisition models outperformed the raw method in term of tumor contrast (7.97:1 mean T:B) but with a difficulty of real-time use. Both acquisition models reached the same detection performance with references (0.8 mean AUC and 0.77 mean NCC), where PM slightly improves the mean tumor contrast up to 10.1:1 vs 9.9:1 with the LUT model and more importantly, it reduces the mean computation time by 7.5%. Our model gives a faster solution for an intraoperative use of navigated beta-probe surface imaging system, with improved image quality.
First in situ TOF-PET study using digital photon counters for proton range verification.
Cambraia Lopes, P; Bauer, J; Salomon, A; Rinaldi, I; Tabacchini, V; Tessonnier, T; Crespo, P; Parodi, K; Schaart, D R
2016-08-21
Positron emission tomography (PET) is the imaging modality most extensively tested for treatment monitoring in particle therapy. Optimal use of PET in proton therapy requires in situ acquisition of the relatively strong (15)O signal due to its relatively short half-life (~2 min) and high oxygen content in biological tissues, enabling shorter scans that are less sensitive to biological washout. This paper presents the first performance tests of a scaled-down in situ time-of-flight (TOF) PET system based on digital photon counters (DPCs) coupled to Cerium-doped Lutetium Yttrium Silicate (LYSO:Ce) crystals, providing quantitative results representative of a dual-head tomograph that complies with spatial constraints typically encountered in clinical practice (2 × 50°, of 360°, transaxial angular acceptance). The proton-induced activity inside polymethylmethacrylate (PMMA) and polyethylene (PE) phantoms was acquired within beam pauses (in-beam) and immediately after irradiation by an actively-delivered synchrotron pencil-beam, with clinically relevant 125.67 MeV/u, 4.6 × 10(8) protons s(-1), and 10(10) total protons. 3D activity maps reconstructed with and without TOF information are compared to FLUKA simulations, demonstrating the benefit of TOF-PET to reduce limited-angle artefacts using a 382 ps full width at half maximum coincidence resolving time. The time-dependent contributions from different radionuclides to the total count-rate are investigated. We furthermore study the impact of the acquisition time window on the laterally integrated activity depth-profiles, with emphasis on 2 min acquisitions starting at different time points. The results depend on phantom composition and reflect the differences in relative contributions from the radionuclides originating from carbon and oxygen. We observe very good agreement between the shapes of the simulated and measured activity depth-profiles for post-beam protocols. However, our results also suggest that available experimental cross sections underestimate the production of (10)C for in-beam acquisitions, which in PE results in an overestimation of the predicted activity range by 1.4 mm. The uncertainty in the activity range measured in PMMA using the DPC-based TOF-PET prototype setup equals 0.2 mm-0.3 mm.
First in situ TOF-PET study using digital photon counters for proton range verification
NASA Astrophysics Data System (ADS)
Cambraia Lopes, P.; Bauer, J.; Salomon, A.; Rinaldi, I.; Tabacchini, V.; Tessonnier, T.; Crespo, P.; Parodi, K.; Schaart, D. R.
2016-08-01
Positron emission tomography (PET) is the imaging modality most extensively tested for treatment monitoring in particle therapy. Optimal use of PET in proton therapy requires in situ acquisition of the relatively strong 15O signal due to its relatively short half-life (~2 min) and high oxygen content in biological tissues, enabling shorter scans that are less sensitive to biological washout. This paper presents the first performance tests of a scaled-down in situ time-of-flight (TOF) PET system based on digital photon counters (DPCs) coupled to Cerium-doped Lutetium Yttrium Silicate (LYSO:Ce) crystals, providing quantitative results representative of a dual-head tomograph that complies with spatial constraints typically encountered in clinical practice (2 × 50°, of 360°, transaxial angular acceptance). The proton-induced activity inside polymethylmethacrylate (PMMA) and polyethylene (PE) phantoms was acquired within beam pauses (in-beam) and immediately after irradiation by an actively-delivered synchrotron pencil-beam, with clinically relevant 125.67 MeV/u, 4.6 × 108 protons s-1, and 1010 total protons. 3D activity maps reconstructed with and without TOF information are compared to FLUKA simulations, demonstrating the benefit of TOF-PET to reduce limited-angle artefacts using a 382 ps full width at half maximum coincidence resolving time. The time-dependent contributions from different radionuclides to the total count-rate are investigated. We furthermore study the impact of the acquisition time window on the laterally integrated activity depth-profiles, with emphasis on 2 min acquisitions starting at different time points. The results depend on phantom composition and reflect the differences in relative contributions from the radionuclides originating from carbon and oxygen. We observe very good agreement between the shapes of the simulated and measured activity depth-profiles for post-beam protocols. However, our results also suggest that available experimental cross sections underestimate the production of 10C for in-beam acquisitions, which in PE results in an overestimation of the predicted activity range by 1.4 mm. The uncertainty in the activity range measured in PMMA using the DPC-based TOF-PET prototype setup equals 0.2 mm-0.3 mm.
Hsiao, Ju-Ling; Chen, Rai-Fu
2012-05-01
This study investigates factors affecting the fit between nursing tasks and mobile nursing information systems and the relationships between the task-technology fit of mobile nursing information systems and nurse performance from the perspective of task-technology fit. Survey research recruited nursing staffs as subjects from selected case hospital. A total of 310 questionnaires were sent out, and 219 copies were obtained, indicating a valid response rate of 70.6%. Collected data were analyzed using the structural equation modeling technique. Our study found that dependence tasks have positive effects on information acquisition (γ=0.234, P<.05) and information identification (γ=0.478, P<.001), and independent tasks have significant effects on information acquisition (γ=0.213, P<.05). Therefore, the introduction of mobile nursing information systems in assisting nursing practices can help facilitate both independent and dependent nursing tasks. Our study discovered that the supporting functions of mobile nursing information systems have positive effects on information integration and interpretation (γ=0.365, P<.001), as well as information acquisition (γ=0.253, P<.05). The service supports of mobile nursing information systems have positive effects on information acquisition (γ=0.318, P<.001) and information integration and interpretation (γ=0.143, P<.01). Furthermore, information identification (β=.055, P<.05), information acquisition (β=.176, P<.001), and information integration and interpretation (β=.706, P<.001) provided using mobile nursing information systems have positive effects on nursing performance, indicating 83.2% of totally explained variance. As shown, the use of mobile nursing information systems could provide nursing staffs with real-time and accurate information to increase efficiency and effectiveness in patient-care duties, further improving nursing performance.
Simultaneous excitation system for efficient guided wave structural health monitoring
NASA Astrophysics Data System (ADS)
Hua, Jiadong; Michaels, Jennifer E.; Chen, Xin; Lin, Jing
2017-10-01
Many structural health monitoring systems utilize guided wave transducer arrays for defect detection and localization. Signals are usually acquired using the ;pitch-catch; method whereby each transducer is excited in turn and the response is received by the remaining transducers. When extensive signal averaging is performed, the data acquisition process can be quite time-consuming, especially for metallic components that require a low repetition rate to allow signals to die out. Such a long data acquisition time is particularly problematic if environmental and operational conditions are changing while data are being acquired. To reduce the total data acquisition time, proposed here is a methodology whereby multiple transmitters are simultaneously triggered, and each transmitter is driven with a unique excitation. The simultaneously transmitted waves are captured by one or more receivers, and their responses are processed by dispersion-compensated filtering to extract the response from each individual transmitter. The excitation sequences are constructed by concatenating a series of chirps whose start and stop frequencies are randomly selected from a specified range. The process is optimized using a Monte-Carlo approach to select sequences with impulse-like autocorrelations and relatively flat cross-correlations. The efficacy of the proposed methodology is evaluated by several metrics and is experimentally demonstrated with sparse array imaging of simulated damage.
25 CFR 700.121 - Statement of the basis for the determination of fair market value.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Statement of the basis for the determination of fair market value. At the time of the initiation of... that such amount— (1) Is the full amount believed by the Commission to be just compensation for the... apportionment of the total estimated just compensation for the partial acquisition will be made. In the event...
25 CFR 700.121 - Statement of the basis for the determination of fair market value.
Code of Federal Regulations, 2011 CFR
2011-04-01
... apportionment of the total estimated just compensation for the partial acquisition will be made. In the event... Statement of the basis for the determination of fair market value. At the time of the initiation of... that such amount— (1) Is the full amount believed by the Commission to be just compensation for the...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-18
...-AH29 Defense Federal Acquisition Regulation Supplement: Simplified Acquisition Threshold for... statutory authority to invoke a simplified acquisition threshold that is two times the normal amount to...) to invoke a simplified acquisition threshold that is two times the amount specified at 41 U.S.C 134...
The new classic data acquisition system for NPOI
NASA Astrophysics Data System (ADS)
Sun, B.; Jorgensen, A. M.; Landavazo, M.; Hutter, D. J.; van Belle, G. T.; Mozurkewich, David; Armstrong, J. T.; Schmitt, H. R.; Baines, E. K.; Restaino, S. R.
2014-07-01
The New Classic data acquisition system is an important portion of a new project of stellar surface imaging with the NPOI, funded by the National Science Foundation, and enables the data acquisition necessary for the project. The NPOI can simultaneously deliver beams from 6 telescopes to the beam combining facility, and in the Classic beam combiner these are combined 4 at a time on 3 separate spectrographs with all 15 possible baselines observed. The Classic data acquisition system is limited to 16 of 32 wavelength channels on two spectrographs and limited to 30 s integrations followed by a pause to ush data. Classic also has some limitations in its fringe-tracking capability. These factors, and the fact that Classic incorporates 1990s technology which cannot be easily replaced are motivation for upgrading the data acquisition system. The New Classic data acquisition system is based around modern electronics, including a high-end Stratix FPGA, a 200 MB/s Direct Memory Access card, and a fast modern Linux computer. These allow for continuous recording of all 96 channels across three spectrographs, increasing the total amount of data recorded by a an estimated order of magnitude. The additional computing power on the data acquisition system also allows for the implementation of more sophisticated fringe-tracking algorithms which are needed for the Stellar Surface Imaging project. In this paper we describe the New Classic system design and implementation, describe the background and motivation for the system as well as show some initial results from using it.
Grijalva, Carlos G.; Griffin, Marie R.; Edwards, Kathryn M.; Williams, John V.; Gil, Ana I.; Verastegui, Hector; Hartinger, Stella M.; Vidal, Jorge E.; Klugman, Keith P.; Lanata, Claudio F.
2014-01-01
Background. Animal models suggest that influenza infection favors nasopharyngeal acquisition of pneumococci. We assessed this relationship with influenza and other respiratory viruses in young children. Methods. A case-control study was nested within a prospective cohort study of acute respiratory illness (ARI) in Andean children <3 years of age (RESPIRA-PERU study). Weekly household visits were made to identify ARI and obtain nasal swabs for viral detection using real-time reverse-transcription polymerase chain reaction. Monthly nasopharyngeal (NP) samples were obtained to assess pneumococcal colonization. We determined whether specific respiratory viral ARI episodes occurring within the interval between NP samples increased the risk of NP acquisition of new pneumococcal serotypes. Results. A total of 729 children contributed 2128 episodes of observation, including 681 pneumococcal acquisition episodes (new serotype, not detected in prior sample), 1029 nonacquisition episodes (no colonization or persistent colonization with the same serotype as the prior sample), and 418 indeterminate episodes. The risk of pneumococcal acquisition increased following influenza-ARI (adjusted odds ratio [AOR], 2.19; 95% confidence interval [CI], 1.02–4.69) and parainfluenza-ARI (AOR, 1.86; 95% CI, 1.15–3.01), when compared with episodes without ARI. Other viral infections (respiratory syncytial virus, human metapneumovirus, human rhinovirus, and adenovirus) were not associated with acquisition. Conclusions. Influenza and parainfluenza ARIs appeared to facilitate pneumococcal acquisition among young children. As acquisition increases the risk of pneumococcal diseases, these observations are pivotal in our attempts to prevent pneumococcal disease. PMID:24621951
48 CFR 207.103 - Agency-head responsibilities.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Office of the Executive Director for Conventional Ammunition. [71 FR 53045, Sept. 8, 2006, as amended at..., as defined in FAR 35.001, when the total cost of all contracts for the acquisition program is estimated at $10 million or more; (B) Acquisitions for production or services when the total cost of all...
48 CFR 207.103 - Agency-head responsibilities.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Office of the Executive Director for Conventional Ammunition. [71 FR 53045, Sept. 8, 2006, as amended at..., as defined in FAR 35.001, when the total cost of all contracts for the acquisition program is estimated at $10 million or more; (B) Acquisitions for production or services when the total cost of all...
48 CFR 207.103 - Agency-head responsibilities.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Office of the Executive Director for Conventional Ammunition. [71 FR 53045, Sept. 8, 2006, as amended at..., as defined in FAR 35.001, when the total cost of all contracts for the acquisition program is estimated at $10 million or more; (B) Acquisitions for production or services when the total cost of all...
48 CFR 207.103 - Agency-head responsibilities.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Office of the Executive Director for Conventional Ammunition. [71 FR 53045, Sept. 8, 2006, as amended at..., as defined in FAR 35.001, when the total cost of all contracts for the acquisition program is estimated at $10 million or more; (B) Acquisitions for production or services when the total cost of all...
48 CFR 207.103 - Agency-head responsibilities.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Office of the Executive Director for Conventional Ammunition. [71 FR 53045, Sept. 8, 2006, as amended at..., as defined in FAR 35.001, when the total cost of all contracts for the acquisition program is estimated at $10 million or more; (B) Acquisitions for production or services when the total cost of all...
Preliminary Results on Design and Implementation of a Solar Radiation Monitoring System
Balan, Mugur C.; Damian, Mihai; Jäntschi, Lorentz
2008-01-01
The paper presents a solar radiation monitoring system, using two scientific pyranometers and an on-line computer home-made data acquisition system. The first pyranometer measures the global solar radiation and the other one, which is shaded, measure the diffuse radiation. The values of total and diffuse solar radiation are continuously stored into a database on a server. Original software was created for data acquisition and interrogation of the created system. The server application acquires the data from pyranometers and stores it into a database with a baud rate of one record at 50 seconds. The client-server application queries the database and provides descriptive statistics. A web interface allow to any user to define the including criteria and to obtain the results. In terms of results, the system is able to provide direct, diffuse and total radiation intensities as time series. Our client-server application computes also derivate heats. The ability of the system to evaluate the local solar energy potential is highlighted. PMID:27879746
Papadimitriou, Lila; Xanthos, Theodoros; Bassiakou, Eleni; Stroumpoulis, Kostantinos; Barouxis, Dimitrios; Iacovidou, Nicolleta
2010-03-01
The present study aims to investigate whether the distribution of the Basic Life Support and Automated External Defibrillation (BLS/AED) manual, 4 weeks prior to the course, has an effect on skill acquisition, theoretical knowledge and skill retention, compared with courses where manuals were not distributed. A total of 303 laypeople were included in the present study. The courses were randomised with sealed envelopes in 12 courses, where manuals were distributed to participants (group A) and in 12 courses, where manuals were not distributed to participants (group B). The participants were formally evaluated at the end of the course, and at 1, 3 and 6 months after each course. The evaluation procedure was the same at all time intervals and consisted of two distinct parts: a written test and a simulated cardiac arrest scenario. No significant difference was observed between the two groups in skill acquisition at the time of initial training. Furthermore, there was no significant difference between the groups in performing BLS/AED skills at 1, 3 and 6 months after initial training. Theoretical knowledge in either group at the specified time intervals did not exhibit any significant difference. Significant deterioration of skills was observed in both groups between initial training and at 1 month after the course, as well as between the first and third month after the course. The present study shows that distribution of BLS/AED manuals 1 month prior to the course has no effect on theoretical knowledge, skill acquisition and skill retention in laypeople. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.
Holtrop, Joseph L.; Sutton, Bradley P.
2016-01-01
Abstract. A diffusion weighted imaging (DWI) approach that is signal-to-noise ratio (SNR) efficient and can be applied to achieve sub-mm resolutions on clinical 3 T systems was developed. The sequence combined a multislab, multishot pulsed gradient spin echo diffusion scheme with spiral readouts for imaging data and navigators. Long data readouts were used to keep the number of shots, and hence total imaging time, for the three-dimensional acquisition short. Image quality was maintained by incorporating a field-inhomogeneity-corrected image reconstruction to remove distortions associated with long data readouts. Additionally, multiple shots were required for the high-resolution images, necessitating motion induced phase correction through the use of efficiently integrated navigator data. The proposed approach is compared with two-dimensional (2-D) acquisitions that use either a spiral or a typical echo-planar imaging (EPI) acquisition to demonstrate the improved SNR efficiency. The proposed technique provided 71% higher SNR efficiency than the standard 2-D EPI approach. The adaptability of the technique to achieve high spatial resolutions is demonstrated by acquiring diffusion tensor imaging data sets with isotropic resolutions of 1.25 and 0.8 mm. The proposed approach allows for SNR-efficient sub-mm acquisitions of DWI data on clinical 3 T systems. PMID:27088107
48 CFR 852.219-11 - VA notice of total veteran-owned small business set-aside.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false VA notice of total veteran-owned small business set-aside. 852.219-11 Section 852.219-11 Federal Acquisition Regulations System... owned by one or more veterans; (ii) The management and daily business operations of which are controlled...
High-resolution ultrashort echo time (UTE) imaging on human knee with AWSOS sequence at 3.0 T.
Qian, Yongxian; Williams, Ashley A; Chu, Constance R; Boada, Fernando E
2012-01-01
To demonstrate the technical feasibility of high-resolution (0.28-0.14 mm) ultrashort echo time (UTE) imaging on human knee at 3T with the acquisition-weighted stack of spirals (AWSOS) sequence. Nine human subjects were scanned on a 3T MRI scanner with an 8-channel knee coil using the AWSOS sequence and isocenter positioning plus manual shimming. High-resolution UTE images were obtained on the subject knees at TE = 0.6 msec with total acquisition time of 5.12 minutes for 60 slices at an in-plane resolution of 0.28 mm and 10.24 minutes for 40 slices at an in-plane resolution of 0.14 mm. Isocenter positioning, manual shimming, and the 8-channel array coil helped minimize image distortion and achieve high signal-to-noise ratio (SNR). It is technically feasible on a clinical 3T MRI scanner to perform UTE imaging on human knee at very high spatial resolutions (0.28-0.14 mm) within reasonable scan time (5-10 min) using the AWSOS sequence. Copyright © 2011 Wiley Periodicals, Inc.
Language Acquisitional Universals: L1, L2, Pidgins, and FLT.
ERIC Educational Resources Information Center
Wode, Henning
Human capacity for language acquisition is not strictly compartmentalized, with one acquisitional mechanism for the native language and others totally unrelated to it; rather, it consists of a unified mechanism flexible enough to handle various differences in external settings. This learning system operates on the formal properties of the…
48 CFR 252.232-7002 - Progress payments for foreign military sales acquisitions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Progress payments for... System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CLAUSES AND FORMS SOLICITATION... distributed to each country's requirements; and (2) Total price per contract line item applicable to each...
Nael, Kambiz; Khan, Rihan; Choudhary, Gagandeep; Meshksar, Arash; Villablanca, Pablo; Tay, Jennifer; Drake, Kendra; Coull, Bruce M; Kidwell, Chelsea S
2014-07-01
If magnetic resonance imaging (MRI) is to compete with computed tomography for evaluation of patients with acute ischemic stroke, there is a need for further improvements in acquisition speed. Inclusion criteria for this prospective, single institutional study were symptoms of acute ischemic stroke within 24 hours onset, National Institutes of Health Stroke Scale ≥3, and absence of MRI contraindications. A combination of echo-planar imaging (EPI) and a parallel acquisition technique were used on a 3T magnetic resonance (MR) scanner to accelerate the acquisition time. Image analysis was performed independently by 2 neuroradiologists. A total of 62 patients met inclusion criteria. A repeat MRI scan was performed in 22 patients resulting in a total of 84 MRIs available for analysis. Diagnostic image quality was achieved in 100% of diffusion-weighted imaging, 100% EPI-fluid attenuation inversion recovery imaging, 98% EPI-gradient recalled echo, 90% neck MR angiography and 96% of brain MR angiography, and 94% of dynamic susceptibility contrast perfusion scans with interobserver agreements (k) ranging from 0.64 to 0.84. Fifty-nine patients (95%) had acute infarction. There was good interobserver agreement for EPI-fluid attenuation inversion recovery imaging findings (k=0.78; 95% confidence interval, 0.66-0.87) and for detection of mismatch classification using dynamic susceptibility contrast-Tmax (k=0.92; 95% confidence interval, 0.87-0.94). Thirteen acute intracranial hemorrhages were detected on EPI-gradient recalled echo by both observers. A total of 68 and 72 segmental arterial stenoses were detected on contrast-enhanced MR angiography of the neck and brain with k=0.93, 95% confidence interval, 0.84 to 0.96 and 0.87, 95% confidence interval, 0.80 to 0.90, respectively. A 6-minute multimodal MR protocol with good diagnostic quality is feasible for the evaluation of patients with acute ischemic stroke and can result in significant reduction in scan time rivaling that of the multimodal computed tomographic protocol. © 2014 American Heart Association, Inc.
Reid, Stewart E; Dai, James Y; Wang, Jing; Sichalwe, Bupe N; Akpomiemie, Godspower; Cowan, Frances M; Delany-Moretlwe, Sinead; Baeten, Jared M; Hughes, James P; Wald, Anna; Celum, Connie
2010-04-01
Biomedical HIV prevention trials enroll sexually active women at risk of HIV and often discontinue study product during pregnancy. We assessed risk factors for pregnancy and HIV acquisition, and the effect of pregnancy on time off study drug in HIV Prevention Trials Network 039. A total of 1358 HIV negative, herpes simplex virus type 2-seropositive women from South Africa, Zambia, and Zimbabwe were enrolled and followed for up to 18 months. A total of 228 pregnancies occurred; time off study drug due to pregnancy accounted for 4% of woman-years of follow-up among women. Being pregnant was not associated with increased HIV risk (hazard ratio 0.64, 95% confidence interval 0.23-1.80, P = 0.40). However, younger age was associated with increased risk for both pregnancy and HIV. There was no association between condom use as a sole contraceptive and reduced pregnancy incidence; hormonal contraception was not associated with increased HIV risk. Bacterial vaginosis at study entry was associated with increased HIV risk (hazard ratio 2.03, P = 0.02). Pregnancy resulted in only a small amount of woman-time off study drug. Young women are at high risk for HIV and are an appropriate population for HIV prevention trials but also have higher risk of pregnancy. Condom use was not associated with reduced incidence of pregnancy.
Zhang, Yeqing; Wang, Meiling; Li, Yafeng
2018-01-01
For the objective of essentially decreasing computational complexity and time consumption of signal acquisition, this paper explores a resampling strategy and variable circular correlation time strategy specific to broadband multi-frequency GNSS receivers. In broadband GNSS receivers, the resampling strategy is established to work on conventional acquisition algorithms by resampling the main lobe of received broadband signals with a much lower frequency. Variable circular correlation time is designed to adapt to different signal strength conditions and thereby increase the operation flexibility of GNSS signal acquisition. The acquisition threshold is defined as the ratio of the highest and second highest correlation results in the search space of carrier frequency and code phase. Moreover, computational complexity of signal acquisition is formulated by amounts of multiplication and summation operations in the acquisition process. Comparative experiments and performance analysis are conducted on four sets of real GPS L2C signals with different sampling frequencies. The results indicate that the resampling strategy can effectively decrease computation and time cost by nearly 90–94% with just slight loss of acquisition sensitivity. With circular correlation time varying from 10 ms to 20 ms, the time cost of signal acquisition has increased by about 2.7–5.6% per millisecond, with most satellites acquired successfully. PMID:29495301
Zhang, Yeqing; Wang, Meiling; Li, Yafeng
2018-02-24
For the objective of essentially decreasing computational complexity and time consumption of signal acquisition, this paper explores a resampling strategy and variable circular correlation time strategy specific to broadband multi-frequency GNSS receivers. In broadband GNSS receivers, the resampling strategy is established to work on conventional acquisition algorithms by resampling the main lobe of received broadband signals with a much lower frequency. Variable circular correlation time is designed to adapt to different signal strength conditions and thereby increase the operation flexibility of GNSS signal acquisition. The acquisition threshold is defined as the ratio of the highest and second highest correlation results in the search space of carrier frequency and code phase. Moreover, computational complexity of signal acquisition is formulated by amounts of multiplication and summation operations in the acquisition process. Comparative experiments and performance analysis are conducted on four sets of real GPS L2C signals with different sampling frequencies. The results indicate that the resampling strategy can effectively decrease computation and time cost by nearly 90-94% with just slight loss of acquisition sensitivity. With circular correlation time varying from 10 ms to 20 ms, the time cost of signal acquisition has increased by about 2.7-5.6% per millisecond, with most satellites acquired successfully.
Fully phase-encoded MRI near metallic implants using ultrashort echo times and broadband excitation.
Wiens, Curtis N; Artz, Nathan S; Jang, Hyungseok; McMillan, Alan B; Koch, Kevin M; Reeder, Scott B
2018-04-01
To develop a fully phase-encoded MRI method for distortion-free imaging near metallic implants, in clinically feasible acquisition times. An accelerated 3D fully phase-encoded acquisition with broadband excitation and ultrashort echo times is presented, which uses a broadband radiofrequency pulse to excite the entire off-resonance induced by the metallic implant. Furthermore, fully phase-encoded imaging is used to prevent distortions caused by frequency encoding, and to obtain ultrashort echo times for rapidly decaying signal. Phantom and in vivo acquisitions were used to describe the relationship among excitation bandwidth, signal loss near metallic implants, and T 1 weighting. Shorter radiofrequency pulses captured signal closer to the implant by improving spectral coverage and allowing shorter echo times, whereas longer pulses improved T 1 weighting through larger maximum attainable flip angles. Comparisons of fully phase-encoded acquisition with broadband excitation and ultrashort echo times to T 1 -weighted multi-acquisition with variable resonance image combination selective were performed in phantoms and subjects with metallic knee and hip prostheses. These acquisitions had similar contrast and acquisition efficiency. Accelerated fully phase-encoded acquisitions with ultrashort echo times and broadband excitation can generate distortion free images near metallic implants in clinically feasible acquisition times. Magn Reson Med 79:2156-2163, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Fully Phase-Encoded MRI Near Metallic Implants Using Ultrashort Echo Times and Broadband Excitation
Wiens, Curtis N.; Artz, Nathan S.; Jang, Hyungseok; McMillan, Alan B.; Koch, Kevin M.; Reeder, Scott B.
2017-01-01
Purpose To develop a fully phase-encoded MRI method for distortion-free imaging near metallic implants, in clinically feasible acquisition times. Theory and Methods An accelerated 3D fully phase-encoded acquisition with broadband excitation and ultrashort echo times is presented, which uses a broadband radiofrequency pulse to excite the entire off-resonance induced by the metallic implant. Furthermore, fully phase-encoded imaging is used to prevent distortions caused by frequency encoding, and to obtain ultrashort echo times for rapidly decaying signal. Results Phantom and in vivo acquisitions were used to describe the relationship among excitation bandwidth, signal loss near metallic implants, and T1 weighting. Shorter radiofrequency pulses captured signal closer to the implant by improving spectral coverage and allowing shorter echo times, whereas longer pulses improved T1 weighting through larger maximum attainable flip angles. Comparisons of fully phase-encoded acquisition with broadband excitation and ultrashort echo times to T1-weighted multi-acquisition with variable resonance image combination selective were performed in phantoms and subjects with metallic knee and hip prostheses. These acquisitions had similar contrast and acquisition efficiency. Conclusions Accelerated fully phase-encoded acquisitions with ultrashort echo times and broadband excitation can generate distortion free images near metallic implants in clinically feasible acquisition times. Magn Reson Med 000:000–000, 2017. PMID:28833407
KC-46 Tanker Aircraft: Program Generally Stable but Improvements in Managing Schedule Are Needed
2013-02-27
testing, and supplier management. An important contractual requirement (and best practice ) is for Boeing to release 90 percent of the total engineering...design is stable, and manufacturing processes are mature. As we reported last year, while the program has implemented many acquisition best practices ...assessed the program’s acquisition plan to determine compliance with acquisition legislation and acquisition best practices . What GAO Recommends GAO
Mitchell, Erica L; Lee, Dae Y; Sevdalis, Nick; Partsafas, Aaron W; Landry, Gregory J; Liem, Timothy K; Moneta, Gregory L
2011-01-01
practice influences new skill acquisition. The aim of this study was to prospectively investigate the impact of practice distribution (weekly vs monthly) on complex motor skill (end-side vascular anastomosis) acquisition and 4-month retention. twenty-four surgical interns were randomly assigned to weekly training for 4 weeks or monthly training for 4 months, with equal total training times. Performance was assessed before training, immediately after training, after the completion of distributed training, and 4 months later. there was no statistical difference in surgical skill acquisition and retention between the weekly and monthly scheduled groups, as measured by procedural checklist scores, global rating scores of operative performance, final product analysis, and overall performance or assessment of operative "competence." distributed practice results in improvement and retention of a newly acquired surgical skill independent of weekly or monthly practice schedules. Flexibility in a surgical skills laboratory curriculum is possible without adversely affecting training. 2011 Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-10-01
... total acquisition costs (for information technology, life cycle costs) are estimated to be $50 million or more, or (b) The system, regardless of estimated acquisition or life cycle costs, has been...
Code of Federal Regulations, 2014 CFR
2014-10-01
... total acquisition costs (for information technology, life cycle costs) are estimated to be $50 million or more, or (b) The system, regardless of estimated acquisition or life cycle costs, has been...
Code of Federal Regulations, 2013 CFR
2013-10-01
... total acquisition costs (for information technology, life cycle costs) are estimated to be $50 million or more, or (b) The system, regardless of estimated acquisition or life cycle costs, has been...
Code of Federal Regulations, 2012 CFR
2012-10-01
... total acquisition costs (for information technology, life cycle costs) are estimated to be $50 million or more, or (b) The system, regardless of estimated acquisition or life cycle costs, has been...
Code of Federal Regulations, 2010 CFR
2010-10-01
... Section 434.001 Federal Acquisition Regulations System DEPARTMENT OF AGRICULTURE SPECIAL CATEGORIES OF... total acquisition costs (for information technology, life cycle costs) are estimated to be $50 million... Technology Systems Executive. ...
Sun, Yupeng; Li, Li; Liao, Man; Su, Min; Wan, Changchen; Zhang, Lantong; Zhang, Hailin
2018-05-30
In this study, a systematic data acquisition and mining strategy aimed at the traditional Chinese medicine (TCM) complex system based on ultra high-performance liquid chromatography coupled with quadrupole time of flight mass spectrometry (UHPLC-Q-TOF-MS) was reported. The workflow of this strategy is as follows: First, the high resolution mass data are acquired by both data-dependent acquisition mode (DDA) and data-independent acquisition mode (DIA). Then a global data mining that combined targeted and non-targeted compound finding is applied to analyze mass spectral data. Furthermore, some assistant tools, such as key product ions (KPIs), are employed for compound hunting and identification. The TCM Ziwan (ZW, Aster tataricus rhizoma) was used to illustrate this strategy for the first time. In this research, total 131 compounds including organic acids, peptides, terpenes, steroids, flavonoids, coumarins, anthraquinones and aldehydes were identified or tentatively characterized in ZW based on accurate mass measurements within ±5 ppm error, and 50 of them were unambiguously confirmed by comparing standard compounds. Afterwards, based on the traditional Chinese medical theory and the key determinants of firing patterns of ventral tegmental area (VTA) dopamine (DA) neurons in the development of depression, the confirmed compounds were subsequently evaluated the pharmacological effect of activity of VTA DA neurons and anti-depressive efficacy. This research provided not only a chemical profiling for further in vivo study of ZW, but also an efficient data acquisition and mining strategy to profile the chemical constituents and find new bioactive substances for other TCM complex system. Copyright © 2018 Elsevier B.V. All rights reserved.
Jerome, Neil P; Orton, Matthew R; d'Arcy, James A; Collins, David J; Koh, Dow-Mu; Leach, Martin O
2014-01-01
To evaluate the effect on diffusion-weighted image-derived parameters in the apparent diffusion coefficient (ADC) and intra-voxel incoherent motion (IVIM) models from choice of either free-breathing or navigator-controlled acquisition. Imaging was performed with consent from healthy volunteers (n = 10) on a 1.5T Siemens Avanto scanner. Parameter-matched free-breathing and navigator-controlled diffusion-weighted images were acquired, without averaging in the console, for a total scan time of ∼10 minutes. Regions of interest were drawn for renal cortex, renal pyramid, whole kidney, liver, spleen, and paraspinal muscle. An ADC diffusion model for these regions was fitted for b-values ≥ 250 s/mm(2) , using a Levenberg-Marquardt algorithm, and an IVIM model was fitted for all images using a Bayesian method. ADC and IVIM parameters from the two acquisition regimes show no significant differences for the cohort; individual cases show occasional discrepancies, with outliers in parameter estimates arising more commonly from navigator-controlled scans. The navigator-controlled acquisitions showed, on average, a smaller range of movement for the kidneys (6.0 ± 1.4 vs. 10.0 ± 1.7 mm, P = 0.03), but also a smaller number of averages collected (3.9 ± 0.1 vs. 5.5 ± 0.2, P < 0.01) in the allocated time. Navigator triggering offers no advantage in fitted diffusion parameters, whereas free-breathing appears to offer greater confidence in fitted diffusion parameters, with fewer outliers, for matched acquisition periods. Copyright © 2013 Wiley Periodicals, Inc.
Confidence-Based Feature Acquisition
NASA Technical Reports Server (NTRS)
Wagstaff, Kiri L.; desJardins, Marie; MacGlashan, James
2010-01-01
Confidence-based Feature Acquisition (CFA) is a novel, supervised learning method for acquiring missing feature values when there is missing data at both training (learning) and test (deployment) time. To train a machine learning classifier, data is encoded with a series of input features describing each item. In some applications, the training data may have missing values for some of the features, which can be acquired at a given cost. A relevant JPL example is that of the Mars rover exploration in which the features are obtained from a variety of different instruments, with different power consumption and integration time costs. The challenge is to decide which features will lead to increased classification performance and are therefore worth acquiring (paying the cost). To solve this problem, CFA, which is made up of two algorithms (CFA-train and CFA-predict), has been designed to greedily minimize total acquisition cost (during training and testing) while aiming for a specific accuracy level (specified as a confidence threshold). With this method, it is assumed that there is a nonempty subset of features that are free; that is, every instance in the data set includes these features initially for zero cost. It is also assumed that the feature acquisition (FA) cost associated with each feature is known in advance, and that the FA cost for a given feature is the same for all instances. Finally, CFA requires that the base-level classifiers produce not only a classification, but also a confidence (or posterior probability).
Roujol, Sébastien; Basha, Tamer A.; Akçakaya, Mehmet; Foppa, Murilo; Chan, Raymond H.; Kissinger, Kraig V.; Goddu, Beth; Berg, Sophie; Manning, Warren J.; Nezafat, Reza
2013-01-01
Purpose: To evaluate the feasibility of 3D single breath-hold late gadolinium enhancement (LGE) of the left ventricle (LV) using supplemental oxygen and hyperventilation and compressed-sensing acceleration. Methods: Breath-hold metrics (breath-hold duration, diaphragmatic/LV position drift, and maximum variation of RR interval) without and with supplemental oxygen and hyperventilation were assessed in healthy adult subjects using a real time single shot acquisition. Ten healthy subjects and 13 patients then underwent assessment of the proposed 3D breath-hold LGE acquisition (FOV=320×320×100 mm3, resolution=1.6×1.6×5.0 mm3, acceleration rate of 4) and a free breathing acquisition with right hemidiaphragm navigator (NAV) respiratory gating. Semi-quantitative grading of overall image quality, motion artifact, myocardial nulling, and diagnostic value was performed by consensus of two blinded observers. Results: Supplemental oxygenation and hyperventilation increased the breath-hold duration (35±11 s to 58±21 s, p<0.0125) without significant impact on diaphragmatic/LV position drift or maximum variation of RR interval (both p>0.01). LGE images were of similar quality when compared to free breathing acquisitions but with reduced total scan time (85±22 s to 35±6 s, p<0.001). Conclusions: Supplemental oxygenation and hyperventilation allow for prolonged breath-holding and enable single breath-hold 3D accelerated LGE with similar image quality as free breathing with NAV. PMID:24186772
Effects of the frame acquisition rate on the sensitivity of gastro-oesophageal reflux scintigraphy
Codreanu, I; Chamroonrat, W; Edwards, K
2013-01-01
Objective: To compare the sensitivity of gastro-oesophageal reflux (GOR) scintigraphy at 5-s and 60-s frame acquisition rates. Methods: GOR scintigraphy of 50 subjects (1 month–20 years old, mean 42 months) were analysed concurrently using 5-s and 60-s acquisition frames. Reflux episodes were graded as low if activity was detected in the distal half of the oesophagus and high if activity was detected in its upper half or in the oral cavity. For comparison purposes, detected GOR in any number of 5-s frames corresponding to one 60-s frame was counted as one episode. Results: A total of 679 episodes of GOR to the upper oesophagus were counted using a 5-s acquisition technique. Only 183 of such episodes were detected on 60-s acquisition images. To the lower oesophagus, a total of 1749 GOR episodes were detected using a 5-s acquisition technique and only 1045 episodes using 60-s acquisition frames (these also included the high-level GOR on 5-s frames counted as low level on 60-s acquisition frames). 10 patients had high-level GOR episodes that were detected only using a 5-s acquisition technique, leading to a different diagnosis in these patients. No correlation between the number of reflux episodes and the gastric emptying rates was noted. Conclusion: The 5-s frame acquisition technique is more sensitive than the 60-s frame acquisition technique for detecting both high- and low-level GOR. Advances in knowledge: Brief GOR episodes with a relatively low number of radioactive counts are frequently indistinguishable from intense background activity on 60-s acquisition frames. PMID:23520226
Glossary Defense Acquisition Acronyms and Terms
1991-09-01
of work to complete a job or part of a project . Actual Cost A cost sustained in fact, on the basis of costs incurred, as... of a project which shows the activities to be completed and the time to complete them is represented by horizontal lines drawn in proportion to the ...recorded for the total estimated obligations for a program or project in the initial year of funding. (For distinction, see Full
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, L; Low, D; Lee, P
Purpose: To show the first in-human Megavoltage (MV)-Topogram acquisition for the evaluation of the potential for MV-Topogram-based alignment as an alternative to MVCT for reducing dose and imaging time. Methods: A lung cancer patient was enrolled in an ongoing IRB-approved clinical trial at our institute. The patient was set up using the clinical protocol employing positioning lasers. 3.2mm diameter tungsten spheres were placed on the patient’s skin at their alignment tattoos to check surface-based marker concordance between topograms and MVCT. Anterior-Posterior (AP) and lateral (LAT) MV-Topograms were acquired using gantry angles of 0°/90° with a 1mm collimator opening, all MLCmore » leafs open, 4cm/s couch speed, and 12.5s scanning time. The topogram acquisition was immediately followed by the normal MVCT scan acquisition. MV-Topograms were reconstructed from the detector exit-data using in-house developed software. The topograms were also enhanced using contrast-limited adaptive histogram equalization (CLAHE). The MV-Topograms were registered to reference kV-based digitally reconstructed topograms. The localization results were compared against results obtained comparing the clinical MVCT to the kVCT simulation. Results: The shifts using the unenhanced Topograms, enhanced Topograms, and MVCT were (LAT, LONG, VERT, ROLL) (5.8mm, 2.6mm, −5.6mm, 0.34°), (3.9mm, 2.5mm, −2.2mm, 0.65°) and (2.4mm, 1.5mm, −3.0mm, 0.5°), respectively. The magnitude alignment differences between the enhanced Topograms and MVCT were within 1.5 mm and 0.15°. The average MVCT and total Topogram acquisition times were 272.9s ± 31.5s and 46s, respectively. Conclusion: MV-Topograms have the potential for providing equivalent performance with less dose and acquisition time than the traditional MVCT technique. We are evaluating other sites as well as adding patients to develop statistically significant analyses regarding the alignment quality differences. MV-Topograms are likely to be most clinically useful for bony anatomy and radiopaque marker-based alignments. The study was supported by an Accuray Grant.« less
Garcia-Vicente, Ana María; Molina, David; Pérez-Beteta, Julián; Amo-Salas, Mariano; Martínez-González, Alicia; Bueno, Gloria; Tello-Galán, María Jesús; Soriano-Castrejón, Ángel
2017-12-01
To study the influence of dual time point 18F-FDG PET/CT in textural features and SUV-based variables and their relation among them. Fifty-six patients with locally advanced breast cancer (LABC) were prospectively included. All of them underwent a standard 18F-FDG PET/CT (PET-1) and a delayed acquisition (PET-2). After segmentation, SUV variables (SUVmax, SUVmean, and SUVpeak), metabolic tumor volume (MTV), and total lesion glycolysis (TLG) were obtained. Eighteen three-dimensional (3D) textural measures were computed including: run-length matrices (RLM) features, co-occurrence matrices (CM) features, and energies. Differences between all PET-derived variables obtained in PET-1 and PET-2 were studied. Significant differences were found between the SUV-based parameters and MTV obtained in the dual time point PET/CT, with higher values of SUV-based variables and lower MTV in the PET-2 with respect to the PET-1. In relation with the textural parameters obtained in dual time point acquisition, significant differences were found for the short run emphasis, low gray-level run emphasis, short run high gray-level emphasis, run percentage, long run emphasis, gray-level non-uniformity, homogeneity, and dissimilarity. Textural variables showed relations with MTV and TLG. Significant differences of textural features were found in dual time point 18F-FDG PET/CT. Thus, a dynamic behavior of metabolic characteristics should be expected, with higher heterogeneity in delayed PET acquisition compared with the standard PET. A greater heterogeneity was found in bigger tumors.
New Clinically Feasible 3T MRI Protocol to Discriminate Internal Brain Stem Anatomy.
Hoch, M J; Chung, S; Ben-Eliezer, N; Bruno, M T; Fatterpekar, G M; Shepherd, T M
2016-06-01
Two new 3T MR imaging contrast methods, track density imaging and echo modulation curve T2 mapping, were combined with simultaneous multisection acquisition to reveal exquisite anatomic detail at 7 canonical levels of the brain stem. Compared with conventional MR imaging contrasts, many individual brain stem tracts and nuclear groups were directly visualized for the first time at 3T. This new approach is clinically practical and feasible (total scan time = 20 minutes), allowing better brain stem anatomic localization and characterization. © 2016 by American Journal of Neuroradiology.
In Vitro Validation of Rapid MR Measurement of Wave Velocity
Kraft; Fatouros; Corwin; Fei
1997-05-01
A one-dimensional time-of-flight MR sequence, having a total acquisition time of approximately 60 ms, has been employed to determine flow-wave propagation velocities for pulsatile flow in compliant latex tubes. The results were compared with those of two independent methods and were found to be in good agreement. An extension of the same MR method was used to test the validity of the "water-hammer" relationship as a means to assess pulse pressure. Very good agreement was found with direct manometric determinations of pulse pressure.
ERIC Educational Resources Information Center
Segal, Bertha E.
Materials from a teacher workshop on the Total Physical Response method for teaching English as a second language are presented. The technique describes the process of first language acquisition, uses physical activities in the classroom to reinforce learning, and allows a long period of receptive language learning before requiring production. The…
Robillard, Cassandra M; Kerr, Jeremy T
2017-08-01
High costs of land in agricultural regions warrant spatial prioritization approaches to conservation that explicitly consider land prices to produce protected-area networks that accomplish targets efficiently. However, land-use changes in such regions and delays between plan design and implementation may render optimized plans obsolete before implementation occurs. To measure the shelf life of cost-efficient conservation plans, we simulated a land-acquisition and restoration initiative aimed at conserving species at risk in Canada's farmlands. We accounted for observed changes in land-acquisition costs and in agricultural intensity based on censuses of agriculture taken from 1986 to 2011. For each year of data, we mapped costs and areas of conservation priority designated using Marxan. We compared plans to test for changes through time in the arrangement of high-priority sites and in the total cost of each plan. For acquisition costs, we measured the savings from accounting for prices during site selection. Land-acquisition costs and land-use intensity generally rose over time independent of inflation (24-78%), although rates of change were heterogeneous through space and decreased in some areas. Accounting for spatial variation in land price lowered the cost of conservation plans by 1.73-13.9%, decreased the range of costs by 19-82%, and created unique solutions from which to choose. Despite the rise in plan costs over time, the high conservation priority of particular areas remained consistent. Delaying conservation in these critical areas may compromise what optimized conservation plans can achieve. In the case of Canadian farmland, rapid conservation action is cost-effective, even with moderate levels of uncertainty in how to implement restoration goals. © 2016 Society for Conservation Biology.
NASA Astrophysics Data System (ADS)
Wason, H.; Herrmann, F. J.; Kumar, R.
2016-12-01
Current efforts towards dense shot (or receiver) sampling and full azimuthal coverage to produce high resolution images have led to the deployment of multiple source vessels (or streamers) across marine survey areas. Densely sampled marine seismic data acquisition, however, is expensive, and hence necessitates the adoption of sampling schemes that save acquisition costs and time. Compressed sensing is a sampling paradigm that aims to reconstruct a signal--that is sparse or compressible in some transform domain--from relatively fewer measurements than required by the Nyquist sampling criteria. Leveraging ideas from the field of compressed sensing, we show how marine seismic acquisition can be setup as a compressed sensing problem. A step ahead from multi-source seismic acquisition is simultaneous source acquisition--an emerging technology that is stimulating both geophysical research and commercial efforts--where multiple source arrays/vessels fire shots simultaneously resulting in better coverage in marine surveys. Following the design principles of compressed sensing, we propose a pragmatic simultaneous time-jittered time-compressed marine acquisition scheme where single or multiple source vessels sail across an ocean-bottom array firing airguns at jittered times and source locations, resulting in better spatial sampling and speedup acquisition. Our acquisition is low cost since our measurements are subsampled. Simultaneous source acquisition generates data with overlapping shot records, which need to be separated for further processing. We can significantly impact the reconstruction quality of conventional seismic data from jittered data and demonstrate successful recovery by sparsity promotion. In contrast to random (sub)sampling, acquisition via jittered (sub)sampling helps in controlling the maximum gap size, which is a practical requirement of wavefield reconstruction with localized sparsifying transforms. We illustrate our results with simulations of simultaneous time-jittered marine acquisition for 2D and 3D ocean-bottom cable survey.
Sample Acquisition and Caching architecture for the Mars Sample Return mission
NASA Astrophysics Data System (ADS)
Zacny, K.; Chu, P.; Cohen, J.; Paulsen, G.; Craft, J.; Szwarc, T.
This paper presents a Mars Sample Return (MSR) Sample Acquisition and Caching (SAC) study developed for the three rover platforms: MER, MER+, and MSL. The study took into account 26 SAC requirements provided by the NASA Mars Exploration Program Office. For this SAC architecture, the reduction of mission risk was chosen by us as having greater priority than mass or volume. For this reason, we selected a “ One Bit per Core” approach. The enabling technology for this architecture is Honeybee Robotics' “ eccentric tubes” core breakoff approach. The breakoff approach allows the drill bits to be relatively small in diameter and in turn lightweight. Hence, the bits could be returned to Earth with the cores inside them with only a modest increase to the total returned mass, but a significant decrease in complexity. Having dedicated bits allows a reduction in the number of core transfer steps and actuators. It also alleviates the bit life problem, eliminates cross contamination, and aids in hermetic sealing. An added advantage is faster drilling time, lower power, lower energy, and lower Weight on Bit (which reduces Arm preload requirements). Drill bits are based on the BigTooth bit concept, which allows re-use of the same bit multiple times, if necessary. The proposed SAC consists of a 1) Rotary-Percussive Core Drill, 2) Bit Storage Carousel, 3) Cache, 4) Robotic Arm, and 5) Rock Abrasion and Brushing Bit (RABBit), which is deployed using the Drill. The system also includes PreView bits (for viewing of cores prior to caching) and Powder bits for acquisition of regolith or cuttings. The SAC total system mass is less than 22 kg for MER and MER+ size rovers and less than 32 kg for the MSL-size rover.
Gui, Minzhi; Tamhane, Ashish A; Arfanakis, Konstantinos
2008-05-01
To assess the effects of cardiac-induced brain pulsation on the noise of the diffusion tensor in Turboprop (a form of periodically rotated overlapping parallel lines with enhanced reconstruction [PROPELLER] imaging) diffusion tensor imaging (DTI). A total of six healthy human subjects were imaged with cardiac-gated as well as nongated Turboprop DTI. Gated and nongated Turboprop DTI datasets were also simulated using actual data acquired exclusively during the diastolic or systolic period of the cardiac cycle. The total variance of the diffusion tensor (TVDT) was measured and compared between acquisitions. The TVDT near the ventricles was significantly reduced in cardiac-gated compared to nongated Turboprop DTI acquisitions. Furthermore, the effects of brain pulsation were reduced, but not eliminated, when increasing the amount of data collected. Finally, data corrupted by cardiac-induced pulsation were not consistently detected by the step of the conventional Turboprop reconstruction algorithm that evaluates the quality of data in different blades. Thus, the inherent quality weighting of the conventional Turboprop reconstruction algorithm was unable to compensate for the increased noise in the diffusion tensor due to brain pulsation. Cardiac-induced brain pulsation increases the TVDT in Turboprop DTI. Use of cardiac gating to limit data acquisition to the diastolic period of the cardiac cycle reduces the TVDT at the expense of imaging time. (c) 2008 Wiley-Liss, Inc.
Iyama, Yuji; Nakaura, Takeshi; Nagayama, Yasunori; Oda, Seitaro; Utsunomiya, Daisuke; Kidoh, Masafumi; Yuki, Hideaki; Hirata, Kenichiro; Namimoto, Tomohiro; Kitajima, Mika; Morita, Kosuke; Funama, Yoshinori; Takemura, Atsushi; Tokuyasu, Shinichi; Okuaki, Tomoyuki; Yamashita, Yasuyuki
2017-11-01
The purpose of this study was to compare scan time and image quality between magnetic resonance angiography (MRA) of the thoracic aorta using a multi-shot gradient echo planar imaging (MSG-EPI) and MRA using balanced steady-state free precession (b-SSFP). Healthy volunteers (n=17) underwent unenhanced thoracic aorta MRA using balanced steady-state free precession (b-SSFP) and MSG-EPI sequences on a 3T MRI. The acquisition time, total scan time, signal-to-noise ratio (SNR) of the thoracic aorta, and the coefficient of variation (CV) of thoracic aorta were compared with paired t-tests. Two radiologists independently recorded the images' contrast, noise, sharpness, artifacts, and overall quality on a 4-point scale. The acquisition time was 36.2% shorter for MSG-EPI than b-SSFP (115.5±14.4 vs 181.0±14.9s, p<0.01). The total scan time was 40.4% shorter for MSG-EPI than b-SSFP (272±78 vs 456±144s, p<0.01). There was no significant difference in mean SNR between MSG-EPI and b-SSFP scans (17.3±3.6 vs 15.2±4.3, p=0.08). The CV was significantly lower for MSG-EPI than b-SSFP (0.2±0.1 vs. 0.5±0.2, p<0.01). All qualitative scores except for image noise were significantly higher in MSG-EPI than b-SSFP scans (p<0.05). The MSG-EPI sequence is a promising technique for shortening scan time and yielding more homogenous image quality in MRA of thoracic aorta on 3T scanners compared with the b-SSFP. Copyright © 2017 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Birgül, Arzu Ergisi; Zeteroglu, Elvan Sahin; Derman, Meral Taner
2017-01-01
The aim of this study is to examine the effect of the activities enhanced concerning time concept on time concept acquisition of children. The research is a quantitative study in experimental model with pretest-posttest control group aiming to examine the effect of the activities enhanced concerning time concept on time concept acquisition of…
Pérez, Miguel A
2007-01-01
The aim of this study was to address the effect of objective age of acquisition (AoA) on picture-naming latencies when different measures of frequency (cumulative and adult word frequency) and frequency trajectory are taken into account. A total of 80 Spanish participants named a set of 178 pictures. Several multiple regression analyses assessed the influence of AoA, word frequency, frequency trajectory, object familiarity, name agreement, image agreement, image variability, name length, and orthographic neighbourhood density on naming times. The results revealed that AoA is the main predictor of picture-naming times. Cumulative frequency and adult word frequency (written or spoken) appeared as important factors in picture naming, but frequency trajectory and object familiarity did not. Other significant variables were image agreement, image variability, and neighbourhood density. These results (a) provide additional evidence of the predictive power of AoA in naming times independent of word-frequency and (b) suggest that image variability and neighbourhood density should also be taken into account in models of lexical production.
Hill, Shannon B; Faradzhev, Nadir S; Powell, Cedric J
2017-12-01
We discuss the problem of quantifying common sources of statistical uncertainties for analyses of trace levels of surface contamination using X-ray photoelectron spectroscopy. We examine the propagation of error for peak-area measurements using common forms of linear and polynomial background subtraction including the correlation of points used to determine both background and peak areas. This correlation has been neglected in previous analyses, but we show that it contributes significantly to the peak-area uncertainty near the detection limit. We introduce the concept of relative background subtraction variance (RBSV) which quantifies the uncertainty introduced by the method of background determination relative to the uncertainty of the background area itself. The uncertainties of the peak area and atomic concentration and of the detection limit are expressed using the RBSV, which separates the contributions from the acquisition parameters, the background-determination method, and the properties of the measured spectrum. These results are then combined to find acquisition strategies that minimize the total measurement time needed to achieve a desired detection limit or atomic-percentage uncertainty for a particular trace element. Minimization of data-acquisition time is important for samples that are sensitive to x-ray dose and also for laboratories that need to optimize throughput.
Economics of human performance and systems total ownership cost.
Onkham, Wilawan; Karwowski, Waldemar; Ahram, Tareq Z
2012-01-01
Financial costs of investing in people is associated with training, acquisition, recruiting, and resolving human errors have a significant impact on increased total ownership costs. These costs can also affect the exaggerate budgets and delayed schedules. The study of human performance economical assessment in the system acquisition process enhances the visibility of hidden cost drivers which support program management informed decisions. This paper presents the literature review of human total ownership cost (HTOC) and cost impacts on overall system performance. Economic value assessment models such as cost benefit analysis, risk-cost tradeoff analysis, expected value of utility function analysis (EV), growth readiness matrix, multi-attribute utility technique, and multi-regressions model were introduced to reflect the HTOC and human performance-technology tradeoffs in terms of the dollar value. The human total ownership regression model introduces to address the influencing human performance cost component measurement. Results from this study will increase understanding of relevant cost drivers in the system acquisition process over the long term.
Performance of the Defense Acquisition System, 2015 Annual report
2015-09-16
Planned Total (From Start to Completion) Quantity-Adjusted Unit -Procurement Recurring-Flyaway Funding (1999–2014) NOTE: This measures biennial...PAUC is a different funding measure define by statute (10 United States Code [U.S.C.], sections 2430a and 2432) consisting of the total acquisition... measures that (unlike PAUC and APUC) are fully adjusted for any changes in procurement quantity. These results help compare procurement unit costs
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-03
...] RIN 9000-AL74 Federal Acquisition Regulation; Time-and-Materials and Labor-Hour Contracts for... final rule amending the Federal Acquisition Regulation (FAR) to implement Government Accountability... in the following sections. II. Discussion and Analysis The Civilian Agency Acquisition Council and...
The role of ERTS in the establishment and of a nationwide land cover information system
NASA Technical Reports Server (NTRS)
Abram, P.; Tullos, J.
1974-01-01
The economic potential of utilizing an ERTS type satellite in the development, updating, and maintenance of a nation-wide land cover information system in the post-1977 time frame was examined. Several alternative acquisition systems were evaluated for land cover data acquisition, processing, and interpretation costs in order to determine, on a total life cycle cost basis, under which conditions of user demand (i.e., area of coverage, frequency of coverage, timeliness of information, and level of information detail) an ERTS type satellite would be cost effective, and what the annual cost savings benefits would be. It was concluded that a three satellite system with high and low altitude aircraft and ground survey team utilizing automatic interpretation and classification techniques is an economically sound proposal.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-27
... Acquisition Regulation; Payments Under Time-and-Materials and Labor-Hour Contracts AGENCY: Department of... Acquisition Regulation (FAR) to make necessary revisions to accommodate the authorization to use time-and... significant changes to the regulations for time-and- materials and labor-hour contracts: (1) FAR Case 2003-027...
Automatic analysis of nuclear-magnetic-resonance-spectroscopy clinical research data
NASA Astrophysics Data System (ADS)
Scott, Katherine N.; Wilson, David C.; Bruner, Angela P.; Lyles, Teresa A.; Underhill, Brandon; Geiser, Edward A.; Ballinger, J. Ray; Scott, James D.; Stopka, Christine B.
1998-03-01
A major problem of P-31 nuclear magnetic spectroscopy (MRS) in vivo applications is that when large data sets are acquired, the time invested in data reduction and analysis with currently available technologies may totally overshadow the time required for data acquisition. An example is out MRS monitoring of exercise therapy for patients with peripheral vascular disease. In these, the spectral acquisition requires 90 minutes per patient study, whereas data analysis and reduction requires 6-8 hours. Our laboratory currently uses the proprietary software SA/GE developed by General Electric. However, other software packages have similar limitations. When data analysis takes this long, the researcher does not have the rapid feedback required to ascertain the quality of data acquired nor the result of the study. This highly undesirable even in a research environment, but becomes intolerable in the clinical setting. The purpose of this report is to outline progress towards the development of an automated method for eliminating the spectral analysis burden on the researcher working in the clinical setting.
Scanning superlens microscopy for non-invasive large field-of-view visible light nanoscale imaging
NASA Astrophysics Data System (ADS)
Wang, Feifei; Liu, Lianqing; Yu, Haibo; Wen, Yangdong; Yu, Peng; Liu, Zhu; Wang, Yuechao; Li, Wen Jung
2016-12-01
Nanoscale correlation of structural information acquisition with specific-molecule identification provides new insight for studying rare subcellular events. To achieve this correlation, scanning electron microscopy has been combined with super-resolution fluorescent microscopy, despite its destructivity when acquiring biological structure information. Here we propose time-efficient non-invasive microsphere-based scanning superlens microscopy that enables the large-area observation of live-cell morphology or sub-membrane structures with sub-diffraction-limited resolution and is demonstrated by observing biological and non-biological objects. This microscopy operates in both non-invasive and contact modes with ~200 times the acquisition efficiency of atomic force microscopy, which is achieved by replacing the point of an atomic force microscope tip with an imaging area of microspheres and stitching the areas recorded during scanning, enabling sub-diffraction-limited resolution. Our method marks a possible path to non-invasive cell imaging and simultaneous tracking of specific molecules with nanoscale resolution, facilitating the study of subcellular events over a total cell period.
An eye movement corpus study of the age-of-acquisition effect.
Dirix, Nicolas; Duyck, Wouter
2017-12-01
In the present study, we investigated the effects of word-level age of acquisition (AoA) on natural reading. Previous studies, using multiple language modalities, showed that earlier-learned words are recognized, read, spoken, and responded to faster than words learned later in life. Until now, in visual word recognition the experimental materials were limited to single-word or sentence studies. We analyzed the data of the Ghent Eye-tracking Corpus (GECO; Cop, Dirix, Drieghe, & Duyck, in press), an eyetracking corpus of participants reading an entire novel, resulting in the first eye movement megastudy of AoA effects in natural reading. We found that the ages at which specific words were learned indeed influenced reading times, above other important (correlated) lexical variables, such as word frequency and length. Shorter fixations for earlier-learned words were consistently found throughout the reading process, in both early (single-fixation durations, first-fixation durations, gaze durations) and late (total reading times) measures. Implications for theoretical accounts of AoA effects and eye movements are discussed.
Landsat-7 long-term acquisition plan radiometry - evolution over time
Markham, Brian L; Goward, Samuel; Arvidson, Terry; Barsi, Julia A.; Scaramuzza, Pat
2006-01-01
The Landsat-7 Enhanced Thematic Mapper Plus instrument has two selectable gains for each spectral band. In the acquisition plan, the gains were initially set to maximize the entropy in each scene. One unintended consequence of this strategy was that, at times, dense vegetation saturated band 4 and deserts saturated all bands. A revised strategy, based on a land-cover classification and sun angle thresholds, reduced saturation, but resulted in gain changes occurring within the same scene on multiple overpasses. As the gain changes cause some loss of data and difficulties for some ground processing systems, a procedure was devised to shift the gain changes to the nearest predicted cloudy scenes. The results are still not totally satisfactory as gain changes still impact some scenes and saturation still occurs, particularly in ephemerally snow-covered regions. A primary conclusion of our experience with variable gain on Landsat-7 is that such an approach should not be employed on future global monitoring missions.
The Skylab sleep monitoring experiment - Methodology and initial results
NASA Technical Reports Server (NTRS)
Frost, J. D., Jr.; Delucchi, M. R.; Shumate, W. H.; Booher, C. R.
1975-01-01
The sleep monitoring experiment permitted an objective evaluation of sleep characteristics during the first two manned Skylab flights. Hardware located onboard the spacecraft accomplished data acquisition, analysis, and preservation, thereby permitting near-real-time evaluation of sleep during the flights and more detailed postmission analysis. The crewman studied during the 28-Day Mission showed some decrease in total sleep time and an increase in the percentage of Stage 4 sleep, while the subject in the 59-Day Mission exhibited little change in total sleep time and a small decrease in Stage 4 and REM sleep. Some disruption of sleep characteristics was seen in the final days of both missions, and both subjects exhibited decreases in REM-onset latency in the immediate postflight period. The relatively minor changes seen were not of the type nor magnitude which might be expected to be associated with significant degradation of performance capability.
Fast CT-PRESS-based spiral chemical shift imaging at 3 Tesla.
Mayer, Dirk; Kim, Dong-Hyun; Adalsteinsson, Elfar; Spielman, Daniel M
2006-05-01
A new sequence is presented that combines constant-time point-resolved spectroscopy (CT-PRESS) with fast spiral chemical shift imaging. It allows the acquisition of multivoxel spectra without line splitting with a minimum total measurement time of less than 5 min for a field of view of 24 cm and a nominal 1.5x1.5-cm2 in-plane resolution. Measurements were performed with 17 CS encoding steps in t1 (Deltat1=12.8 ms) and an average echo time of 151 ms, which was determined by simulating the CT-PRESS experiment for the spin systems of glutamate (Glu) and myo-inositol (mI). Signals from N-acetyl-aspartate, total creatine, choline-containing compounds (Cho), Glu, and mI were detected in a healthy volunteer with no or only minor baseline distortions within 14 min on a 3 T MR scanner. Copyright (c) 2006 Wiley-Liss, Inc.
Hobbs, Brian P.; Chandler, Adam G.; Anderson, Ella F.; Herron, Delise H.; Charnsangavej, Chusilp; Yao, James
2013-01-01
Purpose To assess the effects of acquisition duration on computed tomographic (CT) perfusion parameter values in neuroendocrine liver metastases and normal liver tissue. Materials and Methods This retrospective study was institutional review board approved, with waiver of informed consent. CT perfusion studies in 16 patients (median age, 57.5 years; range, 42.0–69.7 years), including six men (median, 54.1 years; range, 42.0–69.7), and 10 women (median, 59.3 years; range 43.6–66.3), with neuroendocrine liver metastases were analyzed by means of distributed parametric modeling to determine tissue blood flow, blood volume, mean transit time, permeability, and hepatic arterial fraction for tumors and normal liver tissue. Analyses were undertaken with acquisition time of 12–590 seconds. Nonparameteric regression analyses were used to evaluate the functional relationships between CT perfusion parameters and acquisition duration. Evidence for time invariance was evaluated for each parameter at multiple time points by inferring the fitted derivative to assess its proximity to zero as a function of acquisition time by using equivalence tests with three levels of confidence (20%, 70%, and 90%). Results CT perfusion parameter values varied, approaching stable values with increasing acquisition duration. Acquisition duration greater than 160 seconds was required to obtain at least low confidence stability in any of the CT perfusion parameters. At 160 seconds of acquisition, all five CT perfusion parameters stabilized with low confidence in tumor and normal tissues, with the exception of hepatic arterial fraction in tumors. After 220 seconds of acquisition, there was stabilization with moderate confidence for blood flow, blood volume, and hepatic arterial fraction in tumors and normal tissue, and for mean transit time in tumors; however, permeability values did not satisfy the moderate stabilization criteria in both tumors and normal tissue until 360 seconds of acquisition. Blood flow, mean transit time, permeability, and hepatic arterial fraction were significantly different between tumor and normal tissue at 360 seconds (P < .001). Conclusion CT perfusion parameter values are affected by acquisition duration and approach progressively stable values with increasing acquisition times. © RSNA, 2013 Online supplemental material is available for this article. PMID:23824990
NASA Astrophysics Data System (ADS)
Painter, T. H.; Andreadis, K.; Berisford, D. F.; Goodale, C. E.; Hart, A. F.; Heneghan, C.; Deems, J. S.; Gehrke, F.; Marks, D. G.; Mattmann, C. A.; McGurk, B. J.; Ramirez, P.; Seidel, F. C.; Skiles, M.; Trangsrud, A.; Winstral, A. H.; Kirchner, P.; Zimdars, P. A.; Yaghoobi, R.; Boustani, M.; Khudikyan, S.; Richardson, M.; Atwater, R.; Horn, J.; Goods, D.; Verma, R.; Boardman, J. W.
2013-12-01
Snow cover and its melt dominate regional climate and water resources in many of the world's mountainous regions. However, we face significant water resource challenges due to the intersection of increasing demand from population growth and changes in runoff total and timing due to climate change. Moreover, increasing temperatures in desert systems will increase dust loading to mountain snow cover, thus reducing the snow cover albedo and accelerating snowmelt runoff. The two most critical properties for understanding snowmelt runoff and timing are the spatial and temporal distributions of snow water equivalent (SWE) and snow albedo. Despite their importance in controlling volume and timing of runoff, snowpack albedo and SWE are still poorly quantified in the US and not at all in most of the globe, leaving runoff models poorly constrained. Recognizing this need, JPL developed the Airborne Snow Observatory (ASO), an imaging spectrometer and imaging LiDAR system, to quantify snow water equivalent and snow albedo, provide unprecedented knowledge of snow properties, and provide complete, robust inputs to snowmelt runoff models, water management models, and systems of the future. Critical in the design of the ASO system is the availability of snow water equivalent and albedo products within 24 hours of acquisition for timely constraint of snowmelt runoff forecast models. In spring 2013, ASO was deployed for its first year of a multi-year Demonstration Mission of weekly acquisitions in the Tuolumne River Basin (Sierra Nevada) and monthly acquisitions in the Uncompahgre River Basin (Colorado). The ASO data were used to constrain spatially distributed models of varying complexities and integrated into the operations of the O'Shaughnessy Dam on the Hetch Hetchy reservoir on the Tuolumne River. Here we present the first results from the ASO Demonstration Mission 1 along with modeling results with and without the constraint by the ASO's high spatial resolution and spatially complete acquisitions. ASO ultimately provides a potential foundation for coming spaceborne missions.
Zhang, Shuo; Uecker, Martin; Voit, Dirk; Merboldt, Klaus-Dietmar; Frahm, Jens
2010-07-08
Functional assessments of the heart by dynamic cardiovascular magnetic resonance (CMR) commonly rely on (i) electrocardiographic (ECG) gating yielding pseudo real-time cine representations, (ii) balanced gradient-echo sequences referred to as steady-state free precession (SSFP), and (iii) breath holding or respiratory gating. Problems may therefore be due to the need for a robust ECG signal, the occurrence of arrhythmia and beat to beat variations, technical instabilities (e.g., SSFP "banding" artefacts), and limited patient compliance and comfort. Here we describe a new approach providing true real-time CMR with image acquisition times as short as 20 to 30 ms or rates of 30 to 50 frames per second. The approach relies on a previously developed real-time MR method, which combines a strongly undersampled radial FLASH CMR sequence with image reconstruction by regularized nonlinear inversion. While iterative reconstructions are currently performed offline due to limited computer speed, online monitoring during scanning is accomplished using gridding reconstructions with a sliding window at the same frame rate but with lower image quality. Scans of healthy young subjects were performed at 3 T without ECG gating and during free breathing. The resulting images yield T1 contrast (depending on flip angle) with an opposed-phase or in-phase condition for water and fat signals (depending on echo time). They completely avoid (i) susceptibility-induced artefacts due to the very short echo times, (ii) radiofrequency power limitations due to excitations with flip angles of 10 degrees or less, and (iii) the risk of peripheral nerve stimulation due to the use of normal gradient switching modes. For a section thickness of 8 mm, real-time images offer a spatial resolution and total acquisition time of 1.5 mm at 30 ms and 2.0 mm at 22 ms, respectively. Though awaiting thorough clinical evaluation, this work describes a robust and flexible acquisition and reconstruction technique for real-time CMR at the ultimate limit of this technology.
Code of Federal Regulations, 2010 CFR
2010-10-01
...-Hour Proposal Requirements-Non-Commercial Item Acquisition With Adequate Price Competition. 52.216-29... Proposal Requirements—Non-Commercial Item Acquisition With Adequate Price Competition (FEB 2007) (a) The... Time-and-Materials/Labor-Hour Proposal Requirements—Non-Commercial Item Acquisition With Adequate Price...
Hubert: Software for efficient analysis of in-situ nuclear forward scattering experiments
NASA Astrophysics Data System (ADS)
Vrba, Vlastimil; Procházka, Vít; Smrčka, David; Miglierini, Marcel
2016-10-01
Combination of short data acquisition time and local investigation of a solid state through hyperfine parameters makes nuclear forward scattering (NFS) a unique experimental technique for investigation of fast processes. However, the total number of acquired NFS time spectra may be very high. Therefore an efficient way of the data evaluation is needed. In this paper we report the development of Hubert software package as a response to the rapidly developing field of in-situ NFS experiments. Hubert offers several useful features for data files processing and could significantly shorten the evaluation time by using a simple connection between the neighboring time spectra through their input and output parameter values.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mory, Cyril, E-mail: cyril.mory@philips.com; Philips Research Medisys, 33 rue de Verdun, 92156 Suresnes; Auvray, Vincent
2014-02-15
Purpose: Reconstruction of the beating heart in 3D + time in the catheter laboratory using only the available C-arm system would improve diagnosis, guidance, device sizing, and outcome control for intracardiac interventions, e.g., electrophysiology, valvular disease treatment, structural or congenital heart disease. To obtain such a reconstruction, the patient's electrocardiogram (ECG) must be recorded during the acquisition and used in the reconstruction. In this paper, the authors present a 4D reconstruction method aiming to reconstruct the heart from a single sweep 10 s acquisition. Methods: The authors introduce the 4D RecOnstructiOn using Spatial and TEmporal Regularization (short 4D ROOSTER) method,more » which reconstructs all cardiac phases at once, as a 3D + time volume. The algorithm alternates between a reconstruction step based on conjugate gradient and four regularization steps: enforcing positivity, averaging along time outside a motion mask that contains the heart and vessels, 3D spatial total variation minimization, and 1D temporal total variation minimization. Results: 4D ROOSTER recovers the different temporal representations of a moving Shepp and Logan phantom, and outperforms both ECG-gated simultaneous algebraic reconstruction technique and prior image constrained compressed sensing on a clinical case. It generates 3D + time reconstructions with sharp edges which can be used, for example, to estimate the patient's left ventricular ejection fraction. Conclusions: 4D ROOSTER can be applied for human cardiac C-arm CT, and potentially in other dynamic tomography areas. It can easily be adapted to other problems as regularization is decoupled from projection and back projection.« less
17 CFR 240.16a-6 - Small acquisitions.
Code of Federal Regulations, 2010 CFR
2010-04-01
... total of $10,000 in market value; and (2) The person making the acquisition does not within six months... issuer), not exceeding $10,000 in market value shall be reported on Form 5, subject to the following...
Code of Federal Regulations, 2011 CFR
2011-10-01
....202 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT... with the total work required by the contract (engineering estimates of the percentage of completion... contractor, with particular regard to— (i) Attainment of quantity and quality production; (ii) Reduction of...
Computer Support for Conducting Supportability Trade-Offs in a Team Setting
1990-01-01
maintenance visits, and spares costs. To minimize the total system LCC, which includes both acquisition and support costs, a method for obtaining the...from different departments with a range of skills to work for a common goal is not an easy task. Ignoring the logistical concerns, a fundamental problem...maintenance visits, and spares costs. To minimize the total system LCC, which includes both acquisition and support costs, a method for obtaining the
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-25
...-AH29 Defense Federal Acquisition Regulation Supplement; Simplified Acquisition Threshold for.... 2302(7) to invoke a simplified acquisition threshold that is two times the amount specified at 41 U.S.C... acquisition threshold is $150,000 as specified in Federal Acquisition Regulation 2.101. DATES: Effective Date...
Added sugars and ultra-processed foods in Spanish households (1990-2010).
Latasa, P; Louzada, M L D C; Martinez Steele, E; Monteiro, C A
2017-12-26
To study the association between ultra-processed foods acquisitions and added sugar content of total food purchases in Spanish households in 2010. Changes over time (1990-2000-2010) in ultra-processed food purchases and added sugars content of total food purchases are also compared. We used data from three nationally representative Household Budget Surveys (HBS) conducted in 1990, 2000 and 2010. Number of studied households was 21,012, 33,730 and 22,116, respectively. Purchased foods and drinks were classified according to NOVA food groups as ultra-processed foods, processed foods, unprocessed or minimally processed foods, or processed culinary ingredients. Linear and Poisson regressions were used to estimate the association between quintiles of energy contribution of ultra-processed foods and added sugars contents of total food purchases in 2010. Changes over time were assessed using tests of linear trend and Student's t test. In 2010, ultra-processed foods represented 31.7% of daily energy acquisitions and 80.4% of all added sugars. Added sugars content of food purchases raised from 7.3% in the lowest to 18.2% in the highest quintiles of energy contribution of ultra-processed foods. The risk of exceeding 10% energy from added sugars quadrupled between the lowest and highest quintiles. The percentage of ultra-processed foods on all food purchases almost tripled between 1990 and 2010 (from 11.0 to 31.7%), paralleling the increase of added sugars content (from 8.4 to 13.0%). Cutting down exceeding added sugars availability in Spain may require a reduction in ultra-processed food purchasing.
Roujol, Sébastien; Basha, Tamer A; Akçakaya, Mehmet; Foppa, Murilo; Chan, Raymond H; Kissinger, Kraig V; Goddu, Beth; Berg, Sophie; Manning, Warren J; Nezafat, Reza
2014-09-01
To evaluate the feasibility of three-dimensional (3D) single breath-hold late gadolinium enhancement (LGE) of the left ventricle (LV) using supplemental oxygen and hyperventilation and compressed-sensing acceleration. Breath-hold metrics [breath-hold duration, diaphragmatic/LV position drift, and maximum variation of R wave to R wave (RR) interval] without and with supplemental oxygen and hyperventilation were assessed in healthy adult subjects using a real-time single shot acquisition. Ten healthy subjects and 13 patients then underwent assessment of the proposed 3D breath-hold LGE acquisition (field of view = 320 × 320 × 100 mm(3) , resolution = 1.6 × 1.6 × 5.0 mm(3) , acceleration rate of 4) and a free-breathing acquisition with right hemidiaphragm navigator (NAV) respiratory gating. Semiquantitative grading of overall image quality, motion artifact, myocardial nulling, and diagnostic value was performed by consensus of two blinded observers. Supplemental oxygenation and hyperventilation increased the breath-hold duration (35 ± 11 s to 58 ± 21 s; P < 0.0125) without significant impact on diaphragmatic/LV position drift or maximum variation of RR interval (both P > 0.01). LGE images were of similar quality when compared with free-breathing acquisitions, but with reduced total scan time (85 ± 22 s to 35 ± 6 s; P < 0.001). Supplemental oxygenation and hyperventilation allow for prolonged breath-holding and enable single breath-hold 3D accelerated LGE with similar image quality as free breathing with NAV. Copyright © 2013 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Niwa, Arisa; Abe, Shinji; Fujita, Naotoshi; Kono, Hidetaka; Odagawa, Tetsuro; Fujita, Yusuke; Tsuchiya, Saki; Kato, Katsuhiko
2015-03-01
Recently myocardial perfusion SPECT imaging acquired using the cardiac focusing-collimator (CF) has been developed in the field of nuclear cardiology. Previously we have investigated the basic characteristics of CF using physical phantoms. This study was aimed at determining the acquisition time for CF that enables to acquire the SPECT images equivalent to those acquired by the conventional method in 201TlCl myocardial perfusion SPECT. In this study, Siemens Symbia T6 was used by setting the torso phantom equipped with the cardiac, pulmonary, and hepatic components. 201TlCl solution were filled in the left ventricular (LV) myocardium and liver. Each of CF, the low energy high resolution collimator (LEHR), and the low medium energy general purpose collimator (LMEGP) was set on the SPECT equipment. Data acquisitions were made by regarding the center of the phantom as the center of the heart in CF at various acquisition times. Acquired data were reconstructed, and the polar maps were created from the reconstructed images. Coefficient of variation (CV) was calculated as the mean counts determined on the polar maps with their standard deviations. When CF was used, CV was lower at longer acquisition times. CV calculated from the polar maps acquired using CF at 2.83 min of acquisition time was equivalent to CV calculated from those acquired using LEHR in a 180°acquisition range at 20 min of acquisition time.
NASA Astrophysics Data System (ADS)
Nilsson, Thomy H.
2001-09-01
The psychophysical method of limits was used to measure the distance at which observers could distinguish military vehicles photographed in natural landscapes. Obtained from the TNO-TM Search_2 dataset, these pictures either were rear-projected 35-mm slides or were presented on a computer monitor. Based on the rationale that more difficult vehicle targets would require more visual pathways for recognition, difficult of acquisition was defined in terms of the relative retinal area required for recognition. Relative retinal area was derived from the inverse square of the recognition distance of a particular vehicle relative to the distance of the vehicle that could be seen furthest away. Results are compared with data on the time required to find the vehicles in these pictures. These comparison indicate recognition distance thresholds can be a suitable means of defining standards for the effectiveness of vital graphic information; and the two methods are complementary with respect to distinguishing different degrees of acquisition difficulty, and together may provide a means to measure the total information processing required for recognition.
Nishi, Ryuji; Cao, Meng; Kanaji, Atsuko; Nishida, Tomoki; Yoshida, Kiyokazu; Isakozawa, Shigeto
2014-11-01
The ultra-high voltage electron microscope (UHVEM) H-3000 with the world highest acceleration voltage of 3 MV can observe remarkable three dimensional microstructures of microns-thick samples[1]. Acquiring a tilt series of electron tomography is laborious work and thus an automatic technique is highly desired. We proposed the Auto-Focus system using image Sharpness (AFS)[2,3] for UHVEM tomography tilt series acquisition. In the method, five images with different defocus values are firstly acquired and the image sharpness are calculated. The sharpness are then fitted to a quasi-Gaussian function to decide the best focus value[3]. Defocused images acquired by the slow scan CCD (SS-CCD) camera (Hitachi F486BK) are of high quality but one minute is taken for acquisition of five defocused images.In this study, we introduce a high-definition video camera (HD video camera; Hamamatsu Photonics K. K. C9721S) for fast acquisition of images[4]. It is an analog camera but the camera image is captured by a PC and the effective image resolution is 1280×1023 pixels. This resolution is lower than that of the SS-CCD camera of 4096×4096 pixels. However, the HD video camera captures one image for only 1/30 second. In exchange for the faster acquisition the S/N of images are low. To improve the S/N, 22 captured frames are integrated so that each image sharpness is enough to become lower fitting error. As countermeasure against low resolution, we selected a large defocus step, which is typically five times of the manual defocus step, to discriminate different defocused images.By using HD video camera for autofocus process, the time consumption for each autofocus procedure was reduced to about six seconds. It took one second for correction of an image position and the total correction time was seven seconds, which was shorter by one order than that using SS-CCD camera. When we used SS-CCD camera for final image capture, it took 30 seconds to record one tilt image. We can obtain a tilt series of 61 images within 30 minutes. Accuracy and repeatability were good enough to practical use (Figure 1). We successfully reduced the total acquisition time of a tomography tilt series in half than before.jmicro;63/suppl_1/i25/DFU066F1F1DFU066F1Fig. 1.Objective lens current change with a tilt angle during acquisition of tomography series (Sample: a rat hepatocyte, thickness: 2 m, magnification: 4k, acc. voltage: 2 MV). Tilt angle range is ±60 degree with 2 degree step angle. Two series were acquired in the same area. Both data were almost same and the deviation was smaller than the minimum step by manual, so auto-focus worked well. We also developed a computer-aided three dimensional (3D) visualization and analysis software for electron tomography "HawkC" which can sectionalize the 3D data semi-automatically[5,6]. If this auto-acquisition system is used with IMOD reconstruction software[7] and HawkC software, we will be able to do on-line UHVEM tomography. The system would help pathology examination in the future.This work was supported by the Ministry of Education, Culture, Sports, Science and Technology (MEXT), Japan, under a Grant-in-Aid for Scientific Research (Grant No. 23560024, 23560786), and SENTAN, Japan Science and Technology Agency, Japan. © The Author 2014. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Joint Space Operations Center (JSpOC) Mission System Increment 2 (JMS Inc 2)
2016-03-01
Defense Acquisition Executive DoD - Department of Defense DoDAF - DoD Architecture Framework FD - Full Deployment FDD - Full Deployment Decision FY...date has slipped from September 2016 to December 2016 and FDD has slipped from October 2016 to March 2017 since the last MAIS Annual Report...testing. This added test time, in combination with funding reductions and the US Government furlough and shutdown in FY13, caused a total FDD slip
Umeda, Takuro; Miwa, Kenta; Murata, Taisuke; Miyaji, Noriaki; Wagatsuma, Kei; Motegi, Kazuki; Terauchi, Takashi; Koizumi, Mitsuru
2017-12-01
The present study aimed to qualitatively and quantitatively evaluate PET images as a function of acquisition time for various leg sizes, and to optimize a shorter variable-acquisition time protocol for legs to achieve better qualitative and quantitative accuracy of true whole-body PET/CT images. The diameters of legs to be modeled as phantoms were defined based on data derived from 53 patients. This study analyzed PET images of a NEMA phantom and three plastic bottle phantoms (diameter, 5.68, 8.54 and 10.7 cm) that simulated the human body and legs, respectively. The phantoms comprised two spheres (diameters, 10 and 17 mm) containing fluorine-18 fluorodeoxyglucose solution with sphere-to-background ratios of 4 at a background radioactivity level of 2.65 kBq/mL. All PET data were reconstructed with acquisition times ranging from 10 to 180, and 1200 s. We visually evaluated image quality and determined the coefficient of variance (CV) of the background, contrast and the quantitative %error of the hot spheres, and then determined two shorter variable-acquisition protocols for legs. Lesion detectability and quantitative accuracy determined based on maximum standardized uptake values (SUV max ) in PET images of a patient using the proposed protocols were also evaluated. A larger phantom and a shorter acquisition time resulted in increased background noise on images and decreased the contrast in hot spheres. A visual score of ≥ 1.5 was obtained when the acquisition time was ≥ 30 s for three leg phantoms, and ≥ 120 s for the NEMA phantom. The quantitative %errors of the 10- and 17-mm spheres in the leg phantoms were ± 15 and ± 10%, respectively, in PET images with a high CV (scan < 30 s). The mean SUV max of three lesions using the current fixed-acquisition and two proposed variable-acquisition time protocols in the clinical study were 3.1, 3.1 and 3.2, respectively, which did not significantly differ. Leg acquisition time per bed position of even 30-90 s allows axial equalization, uniform image noise and a maximum ± 15% quantitative accuracy for the smallest lesion. The overall acquisition time was reduced by 23-42% using the proposed shorter variable than the current fixed-acquisition time for imaging legs, indicating that this is a useful and practical protocol for routine qualitative and quantitative PET/CT assessment in the clinical setting.
Corbière, Marc; Zaniboni, Sara; Lecomte, Tania; Bond, Gary; Gilles, Pierre-Yves; Lesage, Alain; Goldner, Elliot
2011-09-01
The main purpose of this study was to test a conceptual model based on the theory of planned behaviour (TPB) to explain competitive job acquisition of people with severe mental disorders enrolled in supported employment programs. Using a sample of 281 people with severe mental disorders participating in a prospective study design, the authors examined the contribution of the TPB in a model including clinical (e.g., severity of symptoms), psychosocial (e.g., self-esteem) and work related variables (e.g., length of time absent from the workplace) as predictors of job acquisition. Path analyses were used to test two conceptual models: (1) the model of job acquisition for people with mental illness adapted from the TPB, and (2) the extended TPB including clinical, psychosocial, and work related variables recognized in the literature as significant determinants of competitive employment. Findings revealed that both models presented good fit indices. In total, individual factors predicted 26% of the variance in job search behaviours (behavioural actions). However, client characteristics explained only 8% of variance in work outcomes, suggesting that environmental variables (e.g., stigma towards mental disorders) play an important role in predicting job acquisition. About 56% (N = 157) of our sample obtained competitive employment. Results suggest that employment specialists can be guided in their interventions by the concepts found in the extended model of work integration since most of these are modifiable, such as perceived barriers to employment, self-efficacy, and self-esteem.
Froeling, Martijn; Tax, Chantal M W; Vos, Sjoerd B; Luijten, Peter R; Leemans, Alexander
2017-05-01
In this work, we present the MASSIVE (Multiple Acquisitions for Standardization of Structural Imaging Validation and Evaluation) brain dataset of a single healthy subject, which is intended to facilitate diffusion MRI (dMRI) modeling and methodology development. MRI data of one healthy subject (female, 25 years) were acquired on a clinical 3 Tesla system (Philips Achieva) with an eight-channel head coil. In total, the subject was scanned on 18 different occasions with a total acquisition time of 22.5 h. The dMRI data were acquired with an isotropic resolution of 2.5 mm 3 and distributed over five shells with b-values up to 4000 s/mm 2 and two Cartesian grids with b-values up to 9000 s/mm 2 . The final dataset consists of 8000 dMRI volumes, corresponding B 0 field maps and noise maps for subsets of the dMRI scans, and ten three-dimensional FLAIR, T 1 -, and T 2 -weighted scans. The average signal-to-noise-ratio of the non-diffusion-weighted images was roughly 35. This unique set of in vivo MRI data will provide a robust framework to evaluate novel diffusion processing techniques and to reliably compare different approaches for diffusion modeling. The MASSIVE dataset is made publically available (both unprocessed and processed) on www.massive-data.org. Magn Reson Med 77:1797-1809, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
Measurements of the total cross section of natBe with thermal neutrons from a photo-neutron source
NASA Astrophysics Data System (ADS)
Liu, L. X.; Wang, H. W.; Ma, Y. G.; Cao, X. G.; Cai, X. Z.; Chen, J. G.; Zhang, G. L.; Han, J. L.; Zhang, G. Q.; Hu, J. F.; Wang, X. H.; Li, W. J.; Yan, Z.; Fu, H. J.
2017-11-01
The total neutron cross sections of natural beryllium in the neutron energy region of 0.007 to 0.1 eV were measured by using a time-of-flight (TOF) technique at the Shanghai Institute of Applied Physics (SINAP). The low energy neutrons were obtained by moderating the high energy neutrons from a pulsed photo-neutron source generated from a 16 MeV electron linac. The time dependent neutron background component was determined by employing the 12.8 cm boron-loaded polyethylene (PEB) (5% w.t.) to block neutron TOF path and using the Monte Carlo simulation methods. The present data was compared with the fold Harvey data with the response function of the photo-neutron source (PNS, phase-1). The present measurement of total cross section of natBe for thermal neutrons based on PNS has been developed for the acquisition of nuclear data needed for the Thorium Molten Salt Reactor (TMSR).
Weapon Acquisition Program Outcomes and Efforts to Reform DOD’s Acquisition Process
2016-05-09
portfolio’s total estimated acquisition cost. 11. The equity prices of contractors delivering the ten costliest programs performed well relative to broad...cost growth. • In a constrained funding environment, unforeseen cost increases limit investment choices. The equity prices of the contractors ...remain profitable well into the future • Five publicly-traded defense contractors are developing and delivering the ten largest DOD programs in the 2015
Seekatz, Anna; Bassis, Christine M; Lolans, Karen; Yelin, Rachel D; Moore, Nicholas M; Okamoto, Koh; Rhee, Yoona; Bell, Pamela; Dangana, Thelma; Sidimirova, Galina; Weinstein, Robert A; Fogg, Louis; Lin, Michael Y; Young, Vincent B; Hayden, Mary K
2017-01-01
Abstract Background Colonization with KPC-Kp precedes infection and represents a potential target for intervention. To identify microbial signatures associated with KPC-Kp acquisition, we conducted a prospective, longitudinal study of the fecal microbiota in LTACH patients at risk of acquiring KPC-Kp. Methods We collected admission and weekly rectal swab samples from patients admitted to one LTACH from May 2015 to May 2016. Patients were screened for KPC-Kp by PCR at each sampling time. KPC acquisition was confirmed by culture of KPC-Kp. To assess changes in the microbiota related to acquisition, we sequenced the 16S rRNA gene (V4 region) from collected rectal swabs. Diversity, intra-individual changes, and the relative abundance of the operational taxonomic unit (OTU) that contains KPC-Kp were compared in patients who were KPC-Kp negative upon admission and who had at least one additional swab sample collected. Results 318 patients (1247 samples) were eligible for analysis; 3.7 samples (mean) were collected per patient. Sixty-two patients (19.5%) acquired KPC-Kp (cases) and 256 patients remained negative for all carbapenem-resistant Enterobacteriaceae throughout their stay (controls). Median length of stay before KPC-Kp detection was 14.5 days. At time of KPC-Kp acquisition, levels of an Enterobacteriaceae OTU increased significantly compared with pre-acquisition samples and to samples from control patients (Wilcoxon test, P < 0.0001). Similarly, we observed a decrease in total diversity of the fecal microbiota at time of acquisition in cases (P < 0.01). Compared with controls, cases exhibited decreased intra-individual fecal microbiota similarity immediately prior to acquisition of KPC-Kp (P < 0.01). Comparison of microbial features at time of admission using random forest revealed a higher abundance of Enterococcus and Escherichia OTUs in controls vs cases. Conclusion We observed intra-individual changes in the fecal microbiota of case patients prior to acquisition of KPC-Kp. Compared with patients who did not acquire KPC-Kp, cases exhibited significant changes in microbiota diversity and increased abundance of potential KPC-Kp at acquisition. Our results suggest that shifts in the microbiota may precede colonization by KPC-Kp. Disclosures N. M. Moore, Cepheid: Research Contractor, Funded and provided reagents for associated research projects; R. A. Weinstein, OpGen: Receipt of donated laboratory services for project, Research support; CLorox: Receipt of contributed product, Conducting studies in healthcare facilities that are receiving contributed product; Molnlycke: Receipt of contributed product, Conducting studies in healthcare facilities that are receiving contributed product; Sage Products: Receipt of contributed product, Conducting studies in healthcare facilities that are receiving contributed product; M. Y. Lin, Sage, Inc.: receipt of contributed product, Conducting studies in healthcare facilities that are receiving contributed product; OpGen, Inc.: receipt of in-kind laboratory services, Conducting studies in healthcare facilities that are receiving contributed product; M. K. Hayden, OpGen, Inc.: Receipt of donated laboratory services for project, Research support; Clorox: Receipt of contributed product, Conducting studies in healthcare facilities that are receiving contributed product; Molnlycke: Receipt of contributed product, Conducting studies in healthcare facilities that are receiving contributed product; Sage Products: Receipt of contributed product, Conducting studies in healthcare facilities that are receiving contributed product.
Acquisition of Crosswell Seismic Monitoring Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daley, T.M.; Niu, F.; Silver, P.G.
2008-02-15
Crosswell seismic acquisition provides an ideal geometry for monitoring travel time changes in the subsurface. Analysis of delay time in terms of a characteristic frequency allows us to estimate optimal acquisition parameters (frequency and distance). We have deployed standard data acquisition equipment for continuous monitoring of crosswell travel time in two separate field experiments, with well spacing of 3 and 30 m. The acquisition hardware used for the field experiments is described, along with environmental effects (such as temperature) that influence the measurements. Two field experiments are described that correlate changes in travel time (and therefore velocity) with changes inmore » barometric pressure. The results from the two field sites show a pressure sensitivity for velocity of 10{sup -6}/Pa to 10{sup -8}/Pa.« less
Color Vision Deficits and Literacy Acquisition.
ERIC Educational Resources Information Center
Hurley, Sandra Rollins
1994-01-01
Shows that color blindness, whether partial or total, inhibits literacy acquisition. Offers a case study of a third grader with impaired color vision. Presents a review of literature on the topic. Notes that people with color vision deficits are often unaware of the handicap. (RS)
Marjanovic, Josip; Weiger, Markus; Reber, Jonas; Brunner, David O; Dietrich, Benjamin E; Wilm, Bertram J; Froidevaux, Romain; Pruessmann, Klaas P
2018-02-01
For magnetic resonance imaging of tissues with very short transverse relaxation times, radio-frequency excitation must be immediately followed by data acquisition with fast spatial encoding. In zero-echo-time (ZTE) imaging, excitation is performed while the readout gradient is already on, causing data loss due to an initial dead time. One major dead time contribution is the settling time of the filters involved in signal down-conversion. In this paper, a multi-rate acquisition scheme is proposed to minimize dead time due to filtering. Short filters and high output bandwidth are used initially to minimize settling time. With increasing time since the signal onset, longer filters with better frequency selectivity enable stronger signal decimation. In this way, significant dead time reduction is accomplished at only a slight increase in the overall amount of output data. Multi-rate acquisition was implemented with a two-stage filter cascade in a digital receiver based on a field-programmable gate array. In ZTE imaging in a phantom and in vivo, dead time reduction by multi-rate acquisition is shown to improve image quality and expand the feasible bandwidth while increasing the amount of data collected by only a few percent.
Role of "the frame cycle time" in portal dose imaging using an aS500-II EPID.
Al Kattar Elbalaa, Zeina; Foulquier, Jean Noel; Orthuon, Alexandre; Elbalaa, Hanna; Touboul, Emmanuel
2009-09-01
This paper evaluates the role of an acquisition parameter, the frame cycle time "FCT", in the performance of an aS500-II EPID. The work presented rests on the study of the Varian EPID aS500-II and the image acquisition system 3 (IAS3). We are interested in integrated acquisition using asynchronous mode. For better understanding the image acquisition operation, we investigated the influence of the "frame cycle time" on the speed of acquisition, the pixel value of the averaged gray-scale frame and the noise, using 6 and 15MV X-ray beams and dose rates of 1-6Gy/min on 2100 C/D Linacs. In the integrated mode not synchronized to beam pulses, only one parameter the frame cycle time "FCT" influences the pixel value. The pixel value of the averaged gray-scale frame is proportional to this parameter. When the FCT <55ms (speed of acquisition V(f/s)>18 frames/s), the speed of acquisition becomes unstable and leads to a fluctuation of the portal dose response. A timing instability and saturation are detected when the dose per frame exceeds 1.53MU/frame. Rules were deduced to avoid saturation and to optimize this dosimetric mode. The choice of the acquisition parameter is essential for the accurate portal dose imaging.
Frankel, Tyler; Yonkos, Lance; Ampy, Franklin; Frankel, Jack
2018-04-01
Progestins are utilized as a component of human contraceptives, and commonly enter the environment via wastewater treatment plant effluent. Certain progestins activate fish androgen receptors and cause decreases in fecundity and masculinization of females. We used a nest acquisition assay and computer-assisted sperm analysis to examine the effects of levonorgestrel on male fathead minnow (Pimephales promelas) reproductive fitness. Males were exposed to 0, 10, or 100 ng/L levonorgestrel for 14 d. Combinations of a control male and a male from one of the treatments were placed into a competitive nesting assay, and the time each male spent holding the nest and time spent exhibiting aggressive behaviors were analyzed at 48 h postexposure. Semen samples were analyzed for total motility, straight-line velocity, curvilinear velocity, average path velocity, linearity, beat cross frequency, and wobble at 0, 30, 60, 90, and 120 s postactivation. Males exposed to either 10 or 100 ng/L of levonorgestrel exhibited increased nest acquisition success and lower levels of aggression compared with control-control pairings, as well as decreases in multiple sperm motion characteristics. Our results suggest that further research is required to ascertain the effects of levonorgestrel on male gamete quality and reproductive behaviors. Environ Toxicol Chem 2018;37:1131-1137. © 2017 SETAC. © 2017 SETAC.
Uğurbil, Kamil; Xu, Junqian; Auerbach, Edward J.; Moeller, Steen; Vu, An; Duarte-Carvajalino, Julio M.; Lenglet, Christophe; Wu, Xiaoping; Schmitter, Sebastian; Van de Moortele, Pierre Francois; Strupp, John; Sapiro, Guillermo; De Martino, Federico; Wang, Dingxin; Harel, Noam; Garwood, Michael; Chen, Liyong; Feinberg, David A.; Smith, Stephen M.; Miller, Karla L.; Sotiropoulos, Stamatios N; Jbabdi, Saad; Andersson, Jesper L; Behrens, Timothy EJ; Glasser, Matthew F.; Van Essen, David; Yacoub, Essa
2013-01-01
The human connectome project (HCP) relies primarily on three complementary magnetic resonance (MR) methods. These are: 1) resting state functional MR imaging (rfMRI) which uses correlations in the temporal fluctuations in an fMRI time series to deduce ‘functional connectivity’; 2) diffusion imaging (dMRI), which provides the input for tractography algorithms used for the reconstruction of the complex axonal fiber architecture; and 3) task based fMRI (tfMRI), which is employed to identify functional parcellation in the human brain in order to assist analyses of data obtained with the first two methods. We describe technical improvements and optimization of these methods as well as instrumental choices that impact speed of acquisition of fMRI and dMRI images at 3 Tesla, leading to whole brain coverage with 2 mm isotropic resolution in 0.7 second for fMRI, and 1.25 mm isotropic resolution dMRI data for tractography analysis with three-fold reduction in total data acquisition time. Ongoing technical developments and optimization for acquisition of similar data at 7 Tesla magnetic field are also presented, targeting higher resolution, specificity of functional imaging signals, mitigation of the inhomogeneous radio frequency (RF) fields and power deposition. Results demonstrate that overall, these approaches represent a significant advance in MR imaging of the human brain to investigate brain function and structure. PMID:23702417
NASA Astrophysics Data System (ADS)
Brocks, Sebastian; Bendig, Juliane; Bareth, Georg
2016-10-01
Crop surface models (CSMs) representing plant height above ground level are a useful tool for monitoring in-field crop growth variability and enabling precision agriculture applications. A semiautomated system for generating CSMs was implemented. It combines an Android application running on a set of smart cameras for image acquisition and transmission and a set of Python scripts automating the structure-from-motion (SfM) software package Agisoft Photoscan and ArcGIS. Only ground-control-point (GCP) marking was performed manually. This system was set up on a barley field experiment with nine different barley cultivars in the growing period of 2014. Images were acquired three times a day for a period of two months. CSMs were successfully generated for 95 out of 98 acquisitions between May 2 and June 30. The best linear regressions of the CSM-derived plot-wise averaged plant-heights compared to manual plant height measurements taken at four dates resulted in a coefficient of determination R2 of 0.87 and a root-mean-square error (RMSE) of 0.08 m, with Willmott's refined index of model performance dr equaling 0.78. In total, 103 mean plot heights were used in the regression based on the noon acquisition time. The presented system succeeded in semiautomatedly monitoring crop height on a plot scale to field scale.
Totally Integrated Munitions Enterprise ''Affordable Munitions Production for the 21st Century''
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burleson, R.R.; Poggio, M.E.; Rosenberg, S.J.
2000-07-14
The U.S. Army faces several munitions manufacturing issues: downsizing of the organic production base, timely fielding of affordable smart munitions, and munitions replenishment during national emergencies. TIME is addressing these complex issues via the development and demonstration of an integrated enterprise. The enterprise will include the tools, network, and open modular architecture controller to enable accelerated acquisition, shortened concept to volume production, lower life cycle costs, capture of critical manufacturing processes, and communication of process parameters between remote sites to rapidly spin-off production for replenishment by commercial sources. TIME addresses the enterprise as a system, integrating design, engineering, manufacturing, administration,more » and logistics.« less
Chaudhry, Fouad A; Ismail, Sanaa Z; Davis, Edward T
2018-05-01
Computer-assisted navigation techniques are used to optimise component placement and alignment in total hip replacement. It has developed in the last 10 years but despite its advantages only 0.3% of all total hip replacements in England and Wales are done using computer navigation. One of the reasons for this is that computer-assisted technology increases operative time. A new method of pelvic registration has been developed without the need to register the anterior pelvic plane (BrainLab hip 6.0) which has shown to improve the accuracy of THR. The purpose of this study was to find out if the new method reduces the operating time. This was a retrospective analysis of comparing operating time in computer navigated primary uncemented total hip replacement using two methods of registration. Group 1 included 128 cases that were performed using BrainLab versions 2.1-5.1. This version relied on the acquisition of the anterior pelvic plane for registration. Group 2 included 128 cases that were performed using the newest navigation software, BrainLab hip 6.0 (registration possible with the patient in the lateral decubitus position). The operating time was 65.79 (40-98) minutes using the old method of registration and was 50.87 (33-74) minutes using the new method of registration. This difference was statistically significant. The body mass index (BMI) was comparable in both groups. The study supports the use of new method of registration in improving the operating time in computer navigated primary uncemented total hip replacements.
Acquisition with partial and continuous reinforcement in pigeon autoshaping.
Gottlieb, Daniel A
2004-08-01
Contemporary time accumulation models make the unique prediction that acquisition of a conditioned response will be equally rapid with partial and continuous reinforcement, if the time between conditioned stimuli is held constant. To investigate this, acquisition of conditioned responding was examined in pigeon autoshaping under conditions of 100% and 25% reinforcement, holding intertrial interval constant. Contrary to what was predicted, evidence for slowed acquisition in partially reinforced animals was observed with several response measures. However, asymptotic performance was superior with 25% reinforcement. A switching of reinforcement contingencies after initial acquisition did not immediately affect responding. After further sessions, partial reinforcement augmented responding, whereas continuous reinforcement did not, irrespective of an animal's reinforcement history. Subsequent training with a novel stimulus maintained the response patterns. These acquisition results generally support associative, rather than time accumulation, accounts of conditioning.
48 CFR 31.205-35 - Relocation costs.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Relocation costs. 31.205-35 Section 31.205-35 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL... residences times the current balance of the old mortgage times 3 years. (ii) When mortgage differential...
48 CFR 31.205-35 - Relocation costs.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 1 2014-10-01 2014-10-01 false Relocation costs. 31.205-35 Section 31.205-35 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL... residences times the current balance of the old mortgage times 3 years. (ii) When mortgage differential...
48 CFR 31.205-35 - Relocation costs.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Relocation costs. 31.205-35 Section 31.205-35 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL... residences times the current balance of the old mortgage times 3 years. (ii) When mortgage differential...
48 CFR 31.205-35 - Relocation costs.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Relocation costs. 31.205-35 Section 31.205-35 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL... residences times the current balance of the old mortgage times 3 years. (ii) When mortgage differential...
48 CFR 245.7205 - Reporting excess and surplus contractor inventory.
Code of Federal Regulations, 2010 CFR
2010-10-01
... surplus contractor inventory. 245.7205 Section 245.7205 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACT MANAGEMENT GOVERNMENT PROPERTY Special... the report are self-explanatory except: (1) Line 1—Insert totals from line 7 of the preceding report...
2 CFR 215.23 - Cost sharing or matching.
Code of Federal Regulations, 2010 CFR
2010-01-01
... agency authorizes recipients to donate buildings or land for construction/facilities acquisition projects.... (g) The method used for determining cost sharing or matching for donated equipment, buildings and... the acquisition of equipment, buildings or land, the total value of the donated property may be...
41 CFR 105-72.303 - Cost sharing or matching.
Code of Federal Regulations, 2012 CFR
2012-01-01
... awarding agency authorizes recipients to donate buildings or land for construction/facilities acquisition.... (g) The method used for determining cost sharing or matching for donated equipment, buildings and... the acquisition of equipment, buildings or land, the total value of the donated property may be...
41 CFR 105-72.303 - Cost sharing or matching.
Code of Federal Regulations, 2010 CFR
2010-07-01
... awarding agency authorizes recipients to donate buildings or land for construction/facilities acquisition.... (g) The method used for determining cost sharing or matching for donated equipment, buildings and... the acquisition of equipment, buildings or land, the total value of the donated property may be...
41 CFR 105-72.303 - Cost sharing or matching.
Code of Federal Regulations, 2011 CFR
2011-01-01
... awarding agency authorizes recipients to donate buildings or land for construction/facilities acquisition.... (g) The method used for determining cost sharing or matching for donated equipment, buildings and... the acquisition of equipment, buildings or land, the total value of the donated property may be...
41 CFR 105-72.303 - Cost sharing or matching.
Code of Federal Regulations, 2014 CFR
2014-01-01
... awarding agency authorizes recipients to donate buildings or land for construction/facilities acquisition.... (g) The method used for determining cost sharing or matching for donated equipment, buildings and... the acquisition of equipment, buildings or land, the total value of the donated property may be...
41 CFR 105-72.303 - Cost sharing or matching.
Code of Federal Regulations, 2013 CFR
2013-07-01
... awarding agency authorizes recipients to donate buildings or land for construction/facilities acquisition.... (g) The method used for determining cost sharing or matching for donated equipment, buildings and... the acquisition of equipment, buildings or land, the total value of the donated property may be...
Optimized image acquisition for breast tomosynthesis in projection and reconstruction space.
Chawla, Amarpreet S; Lo, Joseph Y; Baker, Jay A; Samei, Ehsan
2009-11-01
Breast tomosynthesis has been an exciting new development in the field of breast imaging. While the diagnostic improvement via tomosynthesis is notable, the full potential of tomosynthesis has not yet been realized. This may be attributed to the dependency of the diagnostic quality of tomosynthesis on multiple variables, each of which needs to be optimized. Those include dose, number of angular projections, and the total angular span of those projections. In this study, the authors investigated the effects of these acquisition parameters on the overall diagnostic image quality of breast tomosynthesis in both the projection and reconstruction space. Five mastectomy specimens were imaged using a prototype tomosynthesis system. 25 angular projections of each specimen were acquired at 6.2 times typical single-view clinical dose level. Images at lower dose levels were then simulated using a noise modification routine. Each projection image was supplemented with 84 simulated 3 mm 3D lesions embedded at the center of 84 nonoverlapping ROIs. The projection images were then reconstructed using a filtered backprojection algorithm at different combinations of acquisition parameters to investigate which of the many possible combinations maximizes the performance. Performance was evaluated in terms of a Laguerre-Gauss channelized Hotelling observer model-based measure of lesion detectability. The analysis was also performed without reconstruction by combining the model results from projection images using Bayesian decision fusion algorithm. The effect of acquisition parameters on projection images and reconstructed slices were then compared to derive an optimization rule for tomosynthesis. The results indicated that projection images yield comparable but higher performance than reconstructed images. Both modes, however, offered similar trends: Performance improved with an increase in the total acquisition dose level and the angular span. Using a constant dose level and angular span, the performance rolled off beyond a certain number of projections, indicating that simply increasing the number of projections in tomosynthesis may not necessarily improve its performance. The best performance for both projection images and tomosynthesis slices was obtained for 15-17 projections spanning an angular are of approximately 45 degrees--the maximum tested in our study, and for an acquisition dose equal to single-view mammography. The optimization framework developed in this framework is applicable to other reconstruction techniques and other multiprojection systems.
Wiens, Curtis N.; Artz, Nathan S.; Jang, Hyungseok; McMillan, Alan B.; Reeder, Scott B.
2017-01-01
Purpose To develop an externally calibrated parallel imaging technique for three-dimensional multispectral imaging (3D-MSI) in the presence of metallic implants. Theory and Methods A fast, ultrashort echo time (UTE) calibration acquisition is proposed to enable externally calibrated parallel imaging techniques near metallic implants. The proposed calibration acquisition uses a broadband radiofrequency (RF) pulse to excite the off-resonance induced by the metallic implant, fully phase-encoded imaging to prevent in-plane distortions, and UTE to capture rapidly decaying signal. The performance of the externally calibrated parallel imaging reconstructions was assessed using phantoms and in vivo examples. Results Phantom and in vivo comparisons to self-calibrated parallel imaging acquisitions show that significant reductions in acquisition times can be achieved using externally calibrated parallel imaging with comparable image quality. Acquisition time reductions are particularly large for fully phase-encoded methods such as spectrally resolved fully phase-encoded three-dimensional (3D) fast spin-echo (SR-FPE), in which scan time reductions of up to 8 min were obtained. Conclusion A fully phase-encoded acquisition with broadband excitation and UTE enabled externally calibrated parallel imaging for 3D-MSI, eliminating the need for repeated calibration regions at each frequency offset. Significant reductions in acquisition time can be achieved, particularly for fully phase-encoded methods like SR-FPE. PMID:27403613
An important step forward in continuous spectroscopic imaging of ionising radiations using ASICs
NASA Astrophysics Data System (ADS)
Fessler, P.; Coffin, J.; Eberlé, H.; de Raad Iseli, C.; Hilt, B.; Huss, D.; Krummenacher, F.; Lutz, J. R.; Prévot, G.; Renouprez, A.; Sigward, M. H.; Schwaller, B.; Voltolini, C.
1999-01-01
Characterization results are given for an original ASIC allowing continuous acquisition of ionising radiation images in spectroscopic mode. Ionising radiation imaging in general and spectroscopic imaging in particular must primarily be guided by the attempt to decrease statistical noise, which requires detection systems designed to allow very high counting rates. Any source of dead time must therefore be avoided. Thus, the use of on-line corrections of the inevitable dispersion of characteristics between the large number of electronic channels of the detection system, shall be precluded. Without claiming to achieve ultimate noise levels, the work described is focused on how to prevent good individual acquisition channel noise performance from being totally destroyed by the dispersion between channels without introducing dead times. With this goal, we developed an automatic charge amplifier output voltage offset compensation system which operates regardless of the cause of the offset (detector or electronic). The main performances of the system are the following: the input equivalent noise charge is 190 e rms (input non connected, peaking time 500 ns), the highest gain is 255 mV/fC, the peaking time is adjustable between 200 ns and 2 μs and the power consumption is 10 mW per channel. The agreement between experimental data and theoretical simulation results is excellent.
SAR and scan-time optimized 3D whole-brain double inversion recovery imaging at 7T.
Pracht, Eberhard D; Feiweier, Thorsten; Ehses, Philipp; Brenner, Daniel; Roebroeck, Alard; Weber, Bernd; Stöcker, Tony
2018-05-01
The aim of this project was to implement an ultra-high field (UHF) optimized double inversion recovery (DIR) sequence for gray matter (GM) imaging, enabling whole brain coverage in short acquisition times ( ≈5 min, image resolution 1 mm 3 ). A 3D variable flip angle DIR turbo spin echo (TSE) sequence was optimized for UHF application. We implemented an improved, fast, and specific absorption rate (SAR) efficient TSE imaging module, utilizing improved reordering. The DIR preparation was tailored to UHF application. Additionally, fat artifacts were minimized by employing water excitation instead of fat saturation. GM images, covering the whole brain, were acquired in 7 min scan time at 1 mm isotropic resolution. SAR issues were overcome by using a dedicated flip angle calculation considering SAR and SNR efficiency. Furthermore, UHF related artifacts were minimized. The suggested sequence is suitable to generate GM images with whole-brain coverage at UHF. Due to the short total acquisition times and overall robustness, this approach can potentially enable DIR application in a routine setting and enhance lesion detection in neurological diseases. Magn Reson Med 79:2620-2628, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
NASA Astrophysics Data System (ADS)
Vienhage, Paul; Barcomb, Heather; Marshall, Karel; Black, William A.; Coons, Amanda; Tran, Hien T.; Nguyen, Tien M.; Guillen, Andy T.; Yoh, James; Kizer, Justin; Rogers, Blake A.
2017-05-01
The paper describes the MATLAB (MathWorks) programs that were developed during the REU workshop1 to implement The Aerospace Corporation developed Unified Game-based Acquisition Framework and Advanced Game - based Mathematical Framework (UGAF-AGMF) and its associated War-Gaming Engine (WGE) models. Each game can be played from the perspectives of the Department of Defense Acquisition Authority (DAA) or of an individual contractor (KTR). The programs also implement Aerospace's optimum "Program and Technical Baseline (PTB) and associated acquisition" strategy that combines low Total Ownership Cost (TOC) with innovative designs while still meeting warfighter needs. The paper also describes the Bayesian Acquisition War-Gaming approach using Monte Carlo simulations, a numerical analysis technique to account for uncertainty in decision making, which simulate the PTB development and acquisition processes and will detail the procedure of the implementation and the interactions between the games.
Rapid acquisition of HPV around the time of sexual debut in adolescent girls in Tanzania
Houlihan, Catherine F; Baisley, Kathy; Bravo, Ignacio G; Kapiga, Saidi; de Sanjosé, Silvia; Changalucha, John; Ross, David A; Hayes, Richard J; Watson-Jones, Deborah
2016-01-01
Abstract Background: No reports exist on genotype-specific human papillomavirus (HPV) acquisition in girls after first sex in sub-Saharan Africa, despite high HPV prevalence and cervical cancer incidence. Methods: We followed 503 HP-unvaccinated girls aged 15-16 years in Mwanza, Tanzania, 3-monthly for 18 months with interviews and self-administered vaginal swabs. Swabs were tested for 13 higHRisk and 24 low-risk HPV genotypes. Incidence, clearance and duration of overall HPV and genotype-specific infections were calculated and associated factors evaluated. Results : A total of 106 participants reported first sex prior to enrolment ( N = 29) or during follow-up (N = 77). One was HIV-positive at the final visit. The remaining 105 girls contributed 323 adequate specimens. Incidence of any new HPV genotype was 225/100 person-years (pys), and incidence of vaccine types HPV-6, -11, -16 and -18 were 12, 2, 2 and 7/100 pys, respectively. Reporting sex in the past 3 months and knowing the most recent sexual partner for a longer period before sex were associated with HPV acquisition. Median time from reported sexual debut to first HPVinfection was 5 months, and infection duration was 6 months. Conclusion: This is the first description of HPV acquisition after first sex in sub-Saharan Africa where the incidence of cervical cancer is amongst the highest in the world. HPV incidence was very high after first sex, including some vaccine genotypes, and infection duration was short. This very high HPV incidence may help explain high cervical cancer rates, and supports recommendations that the HPV vaccine should be given to girls before first sex. PMID:26944311
Does formal research training lead to academic success in otolaryngology?
Bobian, Michael R; Shah, Noor; Svider, Peter F; Hong, Robert S; Shkoukani, Mahdi A; Folbe, Adam J; Eloy, Jean Anderson
2017-01-01
To evaluate whether formalized research training is associated with higher researcher productivity, academic rank, and acquisition of National Institutes of Health (NIH) grants within academic otolaryngology departments. Each of the 100 civilian otolaryngology program's departmental websites were analyzed to obtain a comprehensive list of faculty members credentials and characteristics, including academic rank, completion of a clinical fellowship, completion of a formal research fellowship, and attainment of a doctorate in philosophy (PhD) degree. We also recorded measures of scholarly impact and successful acquisition of NIH funding. A total of 1,495 academic physicians were included in our study. Of these, 14.1% had formal research training. Bivariate associations showed that formal research training was associated with a greater h-index, increased probability of acquiring NIH funding, and higher academic rank. Using a linear regression model, we found that otolaryngologists possessing a PhD had an associated h-index of 1.8 points higher, and those who completed a formal research fellowship had an h-index of 1.6 points higher. A PhD degree or completion of a research fellowship was not associated with a higher academic rank; however, a higher h-index and previous acquisition of an NIH grant were associated with a higher academic rank. The attainment of NIH funding was three times more likely for those with a formal research fellowship and 8.6 times more likely for otolaryngologists with a PhD degree. Formalized research training is associated with academic success in otolaryngology. Such dedicated research training accompanies greater scholarly impact, acquisition of NIH funding, and a higher academic rank. NA Laryngoscope, 127:E15-E21, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Cooper, Justin T; Harris, Joel M
2014-08-05
The development of techniques to probe interfacial molecular transport is important for understanding and optimizing surface-based analytical methods including surface-enhanced spectroscopies, biological assays, and chemical separations. Single-molecule-fluorescence imaging and tracking has been used to measure lateral diffusion rates of fluorescent molecules at surfaces, but the technique is limited to the study of slower diffusion, where molecules must remain relatively stationary during acquisition of an image in order to build up sufficient intensity in a spot to detect and localize the molecule. Although faster time resolution can be achieved by fluorescence-correlation spectroscopy (FCS), where intensity fluctuations in a small spot are related to the motions of molecules on the surface, long-lived adsorption events arising from surface inhomogeneity can overwhelm the correlation measurement and mask the surface diffusion of the moving population. Here, we exploit a combination of these two techniques, imaging-FCS, for measurement of fast interfacial transport at a model chromatographic surface. This is accomplished by rapid imaging of the surface using an electron-multiplied-charged-coupled-device (CCD) camera, while limiting the acquisition to a small area on the camera to allow fast framing rates. The total intensity from the sampled region is autocorrelated to determine surface diffusion rates of molecules with millisecond time resolution. The technique allows electronic control over the acquisition region, which can be used to avoid strong adsorption sites and thus minimize their contribution to the measured autocorrelation decay and to vary the acquisition area to resolve surface diffusion from adsorption and desorption kinetics. As proof of concept, imaging-FCS was used to measure surface diffusion rates, interfacial populations, and adsorption-desorption rates of 1,1'-dioctadecyl-3,3,3'3'-tetramethylindocarbocyanine (DiI) on planar C18- and C1-modified surfaces.
NASA Astrophysics Data System (ADS)
Durand, Sylvain; Frapart, Yves-Michel; Kerebel, Maud
2017-11-01
Spatial electron paramagnetic resonance imaging (EPRI) is a recent method to localize and characterize free radicals in vivo or in vitro, leading to applications in material and biomedical sciences. To improve the quality of the reconstruction obtained by EPRI, a variational method is proposed to inverse the image formation model. It is based on a least-square data-fidelity term and the total variation and Besov seminorm for the regularization term. To fully comprehend the Besov seminorm, an implementation using the curvelet transform and the L 1 norm enforcing the sparsity is proposed. It allows our model to reconstruct both image where acquisition information are missing and image with details in textured areas, thus opening possibilities to reduce acquisition times. To implement the minimization problem using the algorithm developed by Chambolle and Pock, a thorough analysis of the direct model is undertaken and the latter is inverted while avoiding the use of filtered backprojection (FBP) and of non-uniform Fourier transform. Numerical experiments are carried out on simulated data, where the proposed model outperforms both visually and quantitatively the classical model using deconvolution and FBP. Improved reconstructions on real data, acquired on an irradiated distal phalanx, were successfully obtained.
48 CFR 7.402 - Acquisition methods.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Acquisition methods. 7.402... ACQUISITION PLANNING Equipment Lease or Purchase 7.402 Acquisition methods. (a) Purchase method. (1) Generally, the purchase method is appropriate if the equipment will be used beyond the point in time when...
48 CFR 7.402 - Acquisition methods.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Acquisition methods. 7.402... ACQUISITION PLANNING Equipment Lease or Purchase 7.402 Acquisition methods. (a) Purchase method. (1) Generally, the purchase method is appropriate if the equipment will be used beyond the point in time when...
48 CFR 7.402 - Acquisition methods.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Acquisition methods. 7.402... ACQUISITION PLANNING Equipment Lease or Purchase 7.402 Acquisition methods. (a) Purchase method. (1) Generally, the purchase method is appropriate if the equipment will be used beyond the point in time when...
48 CFR 7.402 - Acquisition methods.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 1 2014-10-01 2014-10-01 false Acquisition methods. 7.402... ACQUISITION PLANNING Equipment Lease or Purchase 7.402 Acquisition methods. (a) Purchase method. (1) Generally, the purchase method is appropriate if the equipment will be used beyond the point in time when...
48 CFR 7.402 - Acquisition methods.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Acquisition methods. 7.402... ACQUISITION PLANNING Equipment Lease or Purchase 7.402 Acquisition methods. (a) Purchase method. (1) Generally, the purchase method is appropriate if the equipment will be used beyond the point in time when...
NASA Astrophysics Data System (ADS)
Girish, B. S.; Pandey, Deepak; Ramachandran, Hema
2017-08-01
We present a compact, inexpensive multichannel module, APODAS (Avalanche Photodiode Output Data Acquisition System), capable of detecting 0.8 billion photons per second and providing real-time recording on a computer hard-disk, of channel- and time-tagged information of the arrival of upto 0.4 billion photons per second. Built around a Virtex-5 Field Programmable Gate Array (FPGA) unit, APODAS offers a temporal resolution of 5 nanoseconds with zero deadtime in data acquisition, utilising an efficient scheme for time and channel tagging and employing Gigabit ethernet for the transfer of data. Analysis tools have been developed on a Linux platform for multi-fold coincidence studies and time-delayed intensity interferometry. As illustrative examples, the second-order intensity correlation function ( g 2) of light from two commonly used sources in quantum optics —a coherent laser source and a dilute atomic vapour emitting spontaneously, constituting a thermal source— are presented. With easy reconfigurability and with no restriction on the total record length, APODAS can be readily used for studies over various time scales. This is demonstrated by using APODAS to reveal Rabi oscillations on nanosecond time scales in the emission of ultracold atoms, on the one hand, and, on the other hand, to measure the second-order correlation function on the millisecond time scales from tailored light sources. The efficient and versatile performance of APODAS promises its utility in diverse fields, like quantum optics, quantum communication, nuclear physics, astrophysics and biology.
76 FR 10384 - Agency Information Collection Activities: Regulation on Agency Protests
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-24
... Protests AGENCY: Office of Chief Procurement Officer, Acquisition Policy and Legislation Office, DHS... Department of Homeland Security, Office of Chief Procurement Officer, Acquisition Policy and Legislation... comments were received by DHS. DHS would also like to correct the Total Burden Cost (capital/startup): $4...
20 CFR 435.23 - Cost sharing or matching.
Code of Federal Regulations, 2012 CFR
2012-04-01
... SSA authorizes recipients to donate buildings or land for construction/facilities acquisition projects... acquisition of equipment, buildings or land, the total value of the donated property may be claimed as cost... method used for determining cost sharing or matching for donated equipment, buildings and land for which...
20 CFR 435.23 - Cost sharing or matching.
Code of Federal Regulations, 2011 CFR
2011-04-01
... SSA authorizes recipients to donate buildings or land for construction/facilities acquisition projects... acquisition of equipment, buildings or land, the total value of the donated property may be claimed as cost... method used for determining cost sharing or matching for donated equipment, buildings and land for which...
20 CFR 435.23 - Cost sharing or matching.
Code of Federal Regulations, 2013 CFR
2013-04-01
... SSA authorizes recipients to donate buildings or land for construction/facilities acquisition projects... acquisition of equipment, buildings or land, the total value of the donated property may be claimed as cost... method used for determining cost sharing or matching for donated equipment, buildings and land for which...
20 CFR 435.23 - Cost sharing or matching.
Code of Federal Regulations, 2010 CFR
2010-04-01
... SSA authorizes recipients to donate buildings or land for construction/facilities acquisition projects... acquisition of equipment, buildings or land, the total value of the donated property may be claimed as cost... method used for determining cost sharing or matching for donated equipment, buildings and land for which...
20 CFR 435.23 - Cost sharing or matching.
Code of Federal Regulations, 2014 CFR
2014-04-01
... SSA authorizes recipients to donate buildings or land for construction/facilities acquisition projects... acquisition of equipment, buildings or land, the total value of the donated property may be claimed as cost... method used for determining cost sharing or matching for donated equipment, buildings and land for which...
48 CFR 232.503-15 - Application of Government title terms.
Code of Federal Regulations, 2012 CFR
2012-10-01
... title terms. 232.503-15 Section 232.503-15 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Progress... took place in the prior month; and (iii) The summary report includes as a minimum, the total number and...
48 CFR 232.503-15 - Application of Government title terms.
Code of Federal Regulations, 2014 CFR
2014-10-01
... title terms. 232.503-15 Section 232.503-15 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Progress... took place in the prior month; and (iii) The summary report includes as a minimum, the total number and...
48 CFR 232.503-15 - Application of Government title terms.
Code of Federal Regulations, 2013 CFR
2013-10-01
... title terms. 232.503-15 Section 232.503-15 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Progress... took place in the prior month; and (iii) The summary report includes as a minimum, the total number and...
48 CFR 232.503-15 - Application of Government title terms.
Code of Federal Regulations, 2010 CFR
2010-10-01
... title terms. 232.503-15 Section 232.503-15 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Progress... place in the prior month; and (iii) The summary report includes as a minimum, the total number and...
48 CFR 232.503-15 - Application of Government title terms.
Code of Federal Regulations, 2011 CFR
2011-10-01
... title terms. 232.503-15 Section 232.503-15 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Progress... place in the prior month; and (iii) The summary report includes as a minimum, the total number and...
Aldridge, Matthew D; Waddington, Wendy W; Dickson, John C; Prakash, Vineet; Ell, Peter J; Bomanji, Jamshed B
2013-11-01
A three-dimensional model-based resolution recovery (RR) reconstruction algorithm that compensates for collimator-detector response, resulting in an improvement in reconstructed spatial resolution and signal-to-noise ratio of single-photon emission computed tomography (SPECT) images, was tested. The software is said to retain image quality even with reduced acquisition time. Clinically, any improvement in patient throughput without loss of quality is to be welcomed. Furthermore, future restrictions in radiotracer supplies may add value to this type of data analysis. The aims of this study were to assess improvement in image quality using the software and to evaluate the potential of performing reduced time acquisitions for bone and parathyroid SPECT applications. Data acquisition was performed using the local standard SPECT/CT protocols for 99mTc-hydroxymethylene diphosphonate bone and 99mTc-methoxyisobutylisonitrile parathyroid SPECT imaging. The principal modification applied was the acquisition of an eight-frame gated data set acquired using an ECG simulator with a fixed signal as the trigger. This had the effect of partitioning the data such that the effect of reduced time acquisitions could be assessed without conferring additional scanning time on the patient. The set of summed data sets was then independently reconstructed using the RR software to permit a blinded assessment of the effect of acquired counts upon reconstructed image quality as adjudged by three experienced observers. Data sets reconstructed with the RR software were compared with the local standard processing protocols; filtered back-projection and ordered-subset expectation-maximization. Thirty SPECT studies were assessed (20 bone and 10 parathyroid). The images reconstructed with the RR algorithm showed improved image quality for both full-time and half-time acquisitions over local current processing protocols (P<0.05). The RR algorithm improved image quality compared with local processing protocols and has been introduced into routine clinical use. SPECT acquisitions are now acquired at half of the time previously required. The method of binning the data can be applied to any other camera system to evaluate the reduction in acquisition time for similar processes. The potential for dose reduction is also inherent with this approach.
Code of Federal Regulations, 2010 CFR
2010-10-01
...-Hour Proposal Requirements-Non-Commercial Item Acquisition without Adequate Price Competition. 52.216... Price Competition. As prescribed in 16.601(e)(2), insert the following provision: Time-and-Materials/Labor-Hour Proposal Requirements—Non-Commercial Item Acquisition Without Adequate Price Competition (FEB...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kohlbrenner, R; Kolli, KP; Taylor, A
2014-06-01
Purpose: To quantify the patient radiation dose reduction achieved during transarterial chemoembolization (TACE) procedures performed in a body interventional radiology suite equipped with the Philips Allura Clarity imaging acquisition and processing platform, compared to TACE procedures performed in the same suite equipped with the Philips Allura Xper platform. Methods: Total fluoroscopy time, cumulative dose area product, and cumulative air kerma were recorded for the first 25 TACE procedures performed to treat hepatocellular carcinoma (HCC) in a Philips body interventional radiology suite equipped with Philips Allura Clarity. The same data were collected for the prior 85 TACE procedures performed to treatmore » HCC in the same suite equipped with Philips Allura Xper. Mean values from these cohorts were compared using two-tailed t tests. Results: Following installation of the Philips Allura Clarity platform, a 42.8% reduction in mean cumulative dose area product (3033.2 versus 1733.6 mGycm∧2, p < 0.0001) and a 31.2% reduction in mean cumulative air kerma (1445.4 versus 994.2 mGy, p < 0.001) was achieved compared to similar procedures performed in the same suite equipped with the Philips Allura Xper platform. Mean total fluoroscopy time was not significantly different between the two cohorts (1679.3 versus 1791.3 seconds, p = 0.41). Conclusion: This study demonstrates a significant patient radiation dose reduction during TACE procedures performed to treat HCC after a body interventional radiology suite was converted to the Philips Allura Clarity platform from the Philips Allura Xper platform. Future work will focus on evaluation of patient dose reduction in a larger cohort of patients across a broader range of procedures and in specific populations, including obese patients and pediatric patients, and comparison of image quality between the two platforms. Funding for this study was provided by Philips Healthcare, with 5% salary support provided to authors K. Pallav Kolli and Robert G. Gould for time devoted to the study. Data acquisition and analysis was performed by the authors independent of the funding source.« less
NASA Astrophysics Data System (ADS)
Paulauskas, A.; Selskis, A.; Bukauskas, V.; Vaicikauskas, V.; Ramanavicius, A.; Balevicius, Z.
2018-01-01
Total internal reflection ellipsometry (TIRE) was utilized in its dynamic data acquisition mode to reveal the percentage of mercury present in an amalgam surface layer. In determining the optical constants of the amalgam film, the non-homogeneities of the formed surface layer were taken into account. The composition of the amalgam layer by percentage was determined using the EMA Bruggemann model for the analysis of the TIRE data. Regression results showed that amalgam layer consisted of mercury 16.00 ± 0.43% and gold 84.00 ± 0.43%. This real time TIRE analysis has shown that for these studies method can detect 0.6 ± 0.4% of mercury on a gold surface, proving that this is a suitable optical technique for obtaining real time readouts. The structural analysis of SEM and AFM have shown that the amalgam layer had a dendritic structure, which formation was determined by the weak adhesion of the gold atoms onto its surface.
2017-10-17
Report: Acquisition of a Multi-Domain Advanced Real- Time Simulator to Support DoD-focused Interdisciplinary Research at CSUB The views, opinions and...reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions...University - Bakersfield Title: Acquisition of a Multi-Domain Advanced Real- Time Simulator to Support DoD-focused Interdisciplinary Research at CSUB Report
Performance of an improved first generation optical CT scanner for 3D dosimetry
NASA Astrophysics Data System (ADS)
Qian, Xin; Adamovics, John; Wuu, Cheng-Shie
2013-12-01
Performance analysis of a modified 3D dosimetry optical scanner based on the first generation optical CT scanner OCTOPUS is presented. The system consists of PRESAGE™ dosimeters, the modified 3D scanner, and a new developed in-house user control panel written in Labview program which provides more flexibility to optimize mechanical control and data acquisition technique. The total scanning time has been significantly reduced from initial 8 h to ∼2 h by using the modified scanner. The functional performance of the modified scanner has been evaluated in terms of the mechanical integrity uncertainty of the data acquisition process. Optical density distribution comparison between the modified scanner, OCTOPUS and the treatment plan system has been studied. It has been demonstrated that the agreement between the modified scanner and treatment plans is comparable with that between the OCTOPUS and treatment plans.
Global crop production forecasting: An analysis of the data system problems and their solutions
NASA Technical Reports Server (NTRS)
Neiers, J.; Graf, H.
1978-01-01
Data related problems in the acquisition and use of satellite data necessary for operational forecasting of global crop production are considered for the purpose of establishing a measurable baseline. For data acquisition the world was divided into 37 crop regions in 22 countries. These regions represent approximately 95 percent of the total world production of the selected crops of interest, i.e., wheat, corn, soybeans, and rice. Targets were assigned to each region. Limited time periods during which data could be taken (windows) were assigned to each target. Each target was assigned to a cloud region. The DSDS was used to measure the success of obtaining data for each target during the specified windows for the regional cloud conditions and the specific alternatives being analyzed. The results of this study suggest several approaches for an operational system that will perform satisfactorily with two LANDSAT type satellites.
One Size Does Not Fit All: How Acquisition Fails the Joint Force Commander
2010-04-02
Campaign Planning and Strategy . The contents of this paper reflect my own personal views and are not necessarily endorsed by the Joint Forces Staff...one-size-fits-all‖ approach has insidiously led to a flawed aircraft acquisition strategy that allows unacceptable risk to combat effectiveness in an...and 78% of the total US tactical aviation fleet. This ―one-size-fits-all‖ approach has insidiously led to a flawed aircraft acquisition strategy
NASA Astrophysics Data System (ADS)
Gladen, R. W.; Chirayath, V. A.; McDonald, A. D.; Fairchild, A. J.; Chrysler, M. D.; Imam, S. K.; Koymen, A. R.; Weiss, A. H.
We describe herein a digital data acquisition system for a time-of-flight Positron annihilation-induced Auger Electron Spectrometer. This data acquisition system consists of a high-speed digitizer collecting signals induced by Auger electrons and annihilation gammas in a multi-channel plate electron detector and a BaF2 gamma detector, respectively. The time intervals between these two signals is used to determine the times of flight of the Auger electrons, which are analyzed by algorithms based on traditional nuclear electronics methods. Ultimately, this digital data acquisition system will be expanded to incorporate the first coincidence measurements of Auger electron and annihilation gamma energies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takahashi, Yutaka; Vagge, Stefano; Agostinelli, Stefano
2015-01-01
Purpose: To develop, characterize, and implement a fast patient localization method for total marrow irradiation. Methods and Materials: Topographic images were acquired using megavoltage computed tomography (MVCT) detector data by delivering static orthogonal beams while the couch traversed through the gantry. Geometric and detector response corrections were performed to generate a megavoltage topogram (MVtopo). We also generated kilovoltage topograms (kVtopo) from the projection data of 3-dimensional CT images to reproduce the same geometry as helical tomotherapy. The MVtopo imaging dose and the optimal image acquisition parameters were investigated. A multi-institutional phantom study was performed to verify the image registration uncertainty. Forty-fivemore » MVtopo images were acquired and analyzed with in-house image registration software. Results: The smallest jaw size (front and backup jaws of 0) provided the best image contrast and longitudinal resolution. Couch velocity did not affect the image quality or geometric accuracy. The MVtopo dose was less than the MVCT dose. The image registration uncertainty from the multi-institutional study was within 2.8 mm. In patient localization, the differences in calculated couch shift between the registration with MVtopo-kVtopo and MVCT-kVCT images in lateral, cranial–caudal, and vertical directions were 2.2 ± 1.7 mm, 2.6 ± 1.4 mm, and 2.7 ± 1.1 mm, respectively. The imaging time in MVtopo acquisition at the couch speed of 3 cm/s was <1 minute, compared with ≥15 minutes in MVCT for all patients. Conclusion: Whole-body MVtopo imaging could be an effective alternative to time-consuming MVCT for total marrow irradiation patient localization.« less
On the reproducibility of expert-operated and robotic ultrasound acquisitions.
Kojcev, Risto; Khakzar, Ashkan; Fuerst, Bernhard; Zettinig, Oliver; Fahkry, Carole; DeJong, Robert; Richmon, Jeremy; Taylor, Russell; Sinibaldi, Edoardo; Navab, Nassir
2017-06-01
We present the evaluation of the reproducibility of measurements performed using robotic ultrasound imaging in comparison with expert-operated sonography. Robotic imaging for interventional procedures may be a valuable contribution, but requires reproducibility for its acceptance in clinical routine. We study this by comparing repeated measurements based on robotic and expert-operated ultrasound imaging. Robotic ultrasound acquisition is performed in three steps under user guidance: First, the patient is observed using a 3D camera on the robot end effector, and the user selects the region of interest. This allows for automatic planning of the robot trajectory. Next, the robot executes a sweeping motion following the planned trajectory, during which the ultrasound images and tracking data are recorded. As the robot is compliant, deviations from the path are possible, for instance due to patient motion. Finally, the ultrasound slices are compounded to create a volume. Repeated acquisitions can be performed automatically by comparing the previous and current patient surface. After repeated image acquisitions, the measurements based on acquisitions performed by the robotic system and expert are compared. Within our case series, the expert measured the anterior-posterior, longitudinal, transversal lengths of both of the left and right thyroid lobes on each of the 4 healthy volunteers 3 times, providing 72 measurements. Subsequently, the same procedure was performed using the robotic system resulting in a cumulative total of 144 clinically relevant measurements. Our results clearly indicated that robotic ultrasound enables more repeatable measurements. A robotic ultrasound platform leads to more reproducible data, which is of crucial importance for planning and executing interventions.
TDRSS telecommunications system, PN code analysis
NASA Technical Reports Server (NTRS)
Dixon, R.; Gold, R.; Kaiser, F.
1976-01-01
The pseudo noise (PN) codes required to support the TDRSS telecommunications services are analyzed and the impact of alternate coding techniques on the user transponder equipment, the TDRSS equipment, and all factors that contribute to the acquisition and performance of these telecommunication services is assessed. Possible alternatives to the currently proposed hybrid FH/direct sequence acquisition procedures are considered and compared relative to acquisition time, implementation complexity, operational reliability, and cost. The hybrid FH/direct sequence technique is analyzed and rejected in favor of a recommended approach which minimizes acquisition time and user transponder complexity while maximizing probability of acquisition and overall link reliability.
48 CFR 1828.311-1 - Contract clause.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Contract clause. 1828.311-1 Section 1828.311-1 Federal Acquisition Regulations System NATIONAL AERONAUTICS AND SPACE ADMINISTRATION... its offer that it is totally immune from tort liability as a State agency or as a charitable...
48 CFR 245.7206 - Transmitting DD Form 1342, DoD Property Record.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Instructions 245.7206 Transmitting DD Form 1342, DoD Property Record. As a minimum, the plant clearance officer... contractor acquired the equipment; (g) Location of the industrial plant equipment; (h) Total acquisition cost..., DoD Property Record. 245.7206 Section 245.7206 Federal Acquisition Regulations System DEFENSE...
48 CFR 647.207-7 - Liability and insurance.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 4 2013-10-01 2013-10-01 false Liability and insurance. 647.207-7 Section 647.207-7 Federal Acquisition Regulations System DEPARTMENT OF STATE CONTRACT....00 per pound (or metric equivalent in local currency) based on the total net weight. The rate...
48 CFR 647.207-7 - Liability and insurance.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 4 2011-10-01 2011-10-01 false Liability and insurance. 647.207-7 Section 647.207-7 Federal Acquisition Regulations System DEPARTMENT OF STATE CONTRACT....00 per pound (or metric equivalent in local currency) based on the total net weight. The rate...
48 CFR 647.207-7 - Liability and insurance.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 4 2014-10-01 2014-10-01 false Liability and insurance. 647.207-7 Section 647.207-7 Federal Acquisition Regulations System DEPARTMENT OF STATE CONTRACT....00 per pound (or metric equivalent in local currency) based on the total net weight. The rate...
48 CFR 647.207-7 - Liability and insurance.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Liability and insurance. 647.207-7 Section 647.207-7 Federal Acquisition Regulations System DEPARTMENT OF STATE CONTRACT....00 per pound (or metric equivalent in local currency) based on the total net weight. The rate...
29 CFR 95.23 - Cost sharing or matching.
Code of Federal Regulations, 2014 CFR
2014-07-01
... buildings or land for construction/facilities acquisition projects or long-term use, the value of the.... (g) The method used for determining cost sharing or matching for donated equipment, buildings and... in the acquisition of equipment, buildings or land, the total value of the donated property may be...
15 CFR 14.23 - Cost sharing or matching.
Code of Federal Regulations, 2010 CFR
2010-01-01
.... If DoC authorizes recipients to donate buildings or land for construction/facilities acquisition... acquisition of equipment, buildings or land, the total value of the donated property may be claimed as cost... method used for determining cost sharing or matching for donated equipment, buildings and land for which...
29 CFR 95.23 - Cost sharing or matching.
Code of Federal Regulations, 2010 CFR
2010-07-01
... buildings or land for construction/facilities acquisition projects or long-term use, the value of the.... (g) The method used for determining cost sharing or matching for donated equipment, buildings and... in the acquisition of equipment, buildings or land, the total value of the donated property may be...
29 CFR 95.23 - Cost sharing or matching.
Code of Federal Regulations, 2011 CFR
2011-07-01
... buildings or land for construction/facilities acquisition projects or long-term use, the value of the.... (g) The method used for determining cost sharing or matching for donated equipment, buildings and... in the acquisition of equipment, buildings or land, the total value of the donated property may be...
29 CFR 95.23 - Cost sharing or matching.
Code of Federal Regulations, 2013 CFR
2013-07-01
... buildings or land for construction/facilities acquisition projects or long-term use, the value of the.... (g) The method used for determining cost sharing or matching for donated equipment, buildings and... in the acquisition of equipment, buildings or land, the total value of the donated property may be...
10 CFR 600.123 - Cost sharing or matching.
Code of Federal Regulations, 2011 CFR
2011-01-01
... buildings or land for construction/facilities acquisition projects or long-term use, the value of the... equipment, buildings and land for which title passes to the recipient may differ according to the purpose of... to assist the recipient in the acquisition of equipment, buildings or land, the total value of the...
15 CFR 14.23 - Cost sharing or matching.
Code of Federal Regulations, 2014 CFR
2014-01-01
.... If DoC authorizes recipients to donate buildings or land for construction/facilities acquisition... acquisition of equipment, buildings or land, the total value of the donated property may be claimed as cost... method used for determining cost sharing or matching for donated equipment, buildings and land for which...
10 CFR 600.123 - Cost sharing or matching.
Code of Federal Regulations, 2013 CFR
2013-01-01
... buildings or land for construction/facilities acquisition projects or long-term use, the value of the... equipment, buildings and land for which title passes to the recipient may differ according to the purpose of... to assist the recipient in the acquisition of equipment, buildings or land, the total value of the...
10 CFR 600.123 - Cost sharing or matching.
Code of Federal Regulations, 2014 CFR
2014-01-01
... buildings or land for construction/facilities acquisition projects or long-term use, the value of the... equipment, buildings and land for which title passes to the recipient may differ according to the purpose of... to assist the recipient in the acquisition of equipment, buildings or land, the total value of the...
10 CFR 600.123 - Cost sharing or matching.
Code of Federal Regulations, 2010 CFR
2010-01-01
... buildings or land for construction/facilities acquisition projects or long-term use, the value of the... equipment, buildings and land for which title passes to the recipient may differ according to the purpose of... to assist the recipient in the acquisition of equipment, buildings or land, the total value of the...
15 CFR 14.23 - Cost sharing or matching.
Code of Federal Regulations, 2012 CFR
2012-01-01
.... If DoC authorizes recipients to donate buildings or land for construction/facilities acquisition... acquisition of equipment, buildings or land, the total value of the donated property may be claimed as cost... method used for determining cost sharing or matching for donated equipment, buildings and land for which...
10 CFR 600.123 - Cost sharing or matching.
Code of Federal Regulations, 2012 CFR
2012-01-01
... buildings or land for construction/facilities acquisition projects or long-term use, the value of the... equipment, buildings and land for which title passes to the recipient may differ according to the purpose of... to assist the recipient in the acquisition of equipment, buildings or land, the total value of the...
15 CFR 14.23 - Cost sharing or matching.
Code of Federal Regulations, 2013 CFR
2013-01-01
.... If DoC authorizes recipients to donate buildings or land for construction/facilities acquisition... acquisition of equipment, buildings or land, the total value of the donated property may be claimed as cost... method used for determining cost sharing or matching for donated equipment, buildings and land for which...
29 CFR 95.23 - Cost sharing or matching.
Code of Federal Regulations, 2012 CFR
2012-07-01
... buildings or land for construction/facilities acquisition projects or long-term use, the value of the.... (g) The method used for determining cost sharing or matching for donated equipment, buildings and... in the acquisition of equipment, buildings or land, the total value of the donated property may be...
15 CFR 14.23 - Cost sharing or matching.
Code of Federal Regulations, 2011 CFR
2011-01-01
.... If DoC authorizes recipients to donate buildings or land for construction/facilities acquisition... acquisition of equipment, buildings or land, the total value of the donated property may be claimed as cost... method used for determining cost sharing or matching for donated equipment, buildings and land for which...
Wiens, Curtis N; Artz, Nathan S; Jang, Hyungseok; McMillan, Alan B; Reeder, Scott B
2017-06-01
To develop an externally calibrated parallel imaging technique for three-dimensional multispectral imaging (3D-MSI) in the presence of metallic implants. A fast, ultrashort echo time (UTE) calibration acquisition is proposed to enable externally calibrated parallel imaging techniques near metallic implants. The proposed calibration acquisition uses a broadband radiofrequency (RF) pulse to excite the off-resonance induced by the metallic implant, fully phase-encoded imaging to prevent in-plane distortions, and UTE to capture rapidly decaying signal. The performance of the externally calibrated parallel imaging reconstructions was assessed using phantoms and in vivo examples. Phantom and in vivo comparisons to self-calibrated parallel imaging acquisitions show that significant reductions in acquisition times can be achieved using externally calibrated parallel imaging with comparable image quality. Acquisition time reductions are particularly large for fully phase-encoded methods such as spectrally resolved fully phase-encoded three-dimensional (3D) fast spin-echo (SR-FPE), in which scan time reductions of up to 8 min were obtained. A fully phase-encoded acquisition with broadband excitation and UTE enabled externally calibrated parallel imaging for 3D-MSI, eliminating the need for repeated calibration regions at each frequency offset. Significant reductions in acquisition time can be achieved, particularly for fully phase-encoded methods like SR-FPE. Magn Reson Med 77:2303-2309, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
Real-time UNIX in HEP data acquisition
NASA Astrophysics Data System (ADS)
Buono, S.; Gaponenko, I.; Jones, R.; Mapelli, L.; Mornacchi, G.; Prigent, D.; Sanchez-Corral, E.; Skiadelli, M.; Toppers, A.; Duval, P. Y.; Ferrato, D.; Le Van Suu, A.; Qian, Z.; Rondot, C.; Ambrosini, G.; Fumagalli, G.; Aguer, M.; Huet, M.
1994-12-01
Today's experimentation in high energy physics is characterized by an increasing need for sensitivity to rare phenomena and complex physics signatures, which require the use of huge and sophisticated detectors and consequently a high performance readout and data acquisition. Multi-level triggering, hierarchical data collection and an always increasing amount of processing power, distributed throughout the data acquisition layers, will impose a number of features on the software environment, especially the need for a high level of standardization. Real-time UNIX seems, today, the best solution for the platform independence, operating system interface standards and real-time features necessary for data acquisition in HEP experiments. We present the results of the evaluation, in a realistic application environment, of a Real-Time UNIX operating system: the EP/LX real-time UNIX system.
Hybrid Ion-Detector/Data-Acquisition System for a TOF-MS
NASA Technical Reports Server (NTRS)
Burton, William D., Jr.; Schultz, J. Albert; Vaughn, Valentine; McCully, Michael; Ulrich, Steven; Egan, Thomas F.
2006-01-01
A modified ion-detector/data-acquisition system has been devised to increase the dynamic range of a time-of-flight mass spectrometer (TOF-MS) that, previously, included a microchannel-plate detector and a data-acquisition system based on counting pulses and time-tagging them by use of a time-to-digital converter (TDC). The dynamic range of the TOF-MS was limited by saturation of the microchannel plate detector, which can handle no more than a few million counts per second. The modified system includes (1) a combined microchannel plate/discrete ion multiplier and (2) a hybrid data-acquisition system that simultaneously performs analog current or voltage measurements and multianode single-ion-pulse-counting time-of-flight measurements to extend the dynamic range of a TDC into the regime in which a mass peak comprises multiple ions arriving simultaneously at the detector. The multianode data are used to determine, in real time, whether the detector is saturated. When saturation is detected, the data-acquisition system selectively enables circuitry that simultaneously determines the ion-peak intensity by measuring the time profile of the analog current or voltage detector-output signal.
MR imaging of ore for heap bioleaching studies using pure phase encode acquisition methods
NASA Astrophysics Data System (ADS)
Fagan, Marijke A.; Sederman, Andrew J.; Johns, Michael L.
2012-03-01
Various MRI techniques were considered with respect to imaging of aqueous flow fields in low grade copper ore. Spin echo frequency encoded techniques were shown to produce unacceptable image distortions which led to pure phase encoded techniques being considered. Single point imaging multiple point acquisition (SPI-MPA) and spin echo single point imaging (SESPI) techniques were applied. By direct comparison with X-ray tomographic images, both techniques were found to be able to produce distortion-free images of the ore packings at 2 T. The signal to noise ratios (SNRs) of the SESPI images were found to be superior to SPI-MPA for equal total acquisition times; this was explained based on NMR relaxation measurements. SESPI was also found to produce suitable images for a range of particles sizes, whereas SPI-MPA SNR deteriorated markedly as particles size was reduced. Comparisons on a 4.7 T magnet showed significant signal loss from the SPI-MPA images, the effect of which was accentuated in the case of unsaturated flowing systems. Hence it was concluded that SESPI was the most robust imaging method for the study of copper ore heap leaching hydrology.
New Acquisition of Antibiotic-Resistant Organisms in Skilled Nursing Facilities
Fisch, Jay; Lansing, Bonnie; Wang, Linda; Symons, Kathleen; Cherian, Kay; McNamara, Sara
2012-01-01
The epidemiology of new acquisition of antibiotic-resistant organisms (AROs) in community-based skilled nursing facilities (SNFs) is not well studied. To define the incidence, persistence of, and time to new colonization with methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant enterococci (VRE), and ceftazidime-resistant (CAZr) and ciprofloxacin-resistant (CIPr) Gram-negative bacteria (GNB) in SNFs, SNF residents were enrolled and specimens from the nares, oropharynx, groin, perianal area, and wounds were prospectively cultured monthly. Standard microbiological tests were used to identify MRSA, VRE, and CAZr and CIPr GNB. Residents with at least 3 months of follow-up were included in the analysis. Colonized residents were categorized as having either preexisting or new acquisition. The time to colonization for new acquisition of AROs was calculated. Eighty-two residents met the eligibility criteria. New acquisition of AROs was common. For example, of the 59 residents colonized with CIPr GNB, 28 (47%) were colonized with CIPr GNB at the start of the study (96% persistent and 4% intermittent), and 31 (53%) acquired CIPr GNB at the facility (61% persistent). The time to new acquisition was shortest for CIPr GNB, at a mean of 75.5 days; the time to new acquisition for MRSA was 126.6 days (P = 0.007 versus CIPr GNB), that for CAZr was 176.0 days (P = 0.0001 versus CIPr GNB), and that for VRE was 186.0 days (P = 0.0004 versus CIPr GNB). Functional status was significantly associated with new acquisition of AROs (odds ratio [OR], 1.24; P = 0.01). New acquisition of AROs, in particular CIPr GNB and MRSA, is common in SNFs. CIPr GNB are acquired rapidly. Additional longitudinal studies to investigate risk factors for ARO acquisition are required. PMID:22378900
NASA Astrophysics Data System (ADS)
Danna, M.; Lecchi, M.; Bettinardi, V.; Gilardi, M.; Stearns, C.; Lucignani, G.; Fazio, F.
2006-02-01
Aim of this work was the implementation and validation, for the Discovery-ST PET/CT (GE Medical Systems) system, of the acquisition-specific noise equivalent counts (AS-NEC) method to establish the amount of tracer to be injected in 3D18F-FDG whole body (WB) PET studies to achieve the peak of the NEC (NEC-p) at the acquisition time. The AS-NEC method uses prompts, delayed events and detector dead-time of a single reference PET scan to calculate the full shape of the NEC curve. The method was implemented using a 3D decay series of the 70 cm NEMA 2001 (line source in a 20 cm diameter solid polyethylene cylinder) phantom and validated with the cylindrical NEMA 1994 (diameter, 20 cm; length, 20 cm) and NEMA 2001 IEC body phantoms. The NEC curves generated by the single frames of the phantom series, using the AS-NEC method, well correlated with the experimental NEC curves proving the validity of the method and the possible application to clinical studies. The AS-NEC model was then retrospectively applied on 40 3D18F-FDG WB studies in a range of body mass index (BMI) between 16 and 30 (kg/m2) (6 under-weight (uw), 18 normal-weight (nw), 16 over-weight (ow)). For each acquisition frame of each patient study, the activity at the acquisition time, corresponding to the NEC-p was identified on the NEC curves. Furthermore, as the NEC curves show a region around the NEC-p with small variations (nearly a plateau), the values of radioactivity corresponding to a reduction of 1%, 3% and 5% with respect to NEC-p were also calculated to assess a possible reduction of the doses to be injected in clinical studies. The results show that the average activities at the acquisition time corresponding to the NEC-p were comparable for the three BMI classes: 336.7 MBq (sd=22.2), 329.3 MBq (sd=33.3), 344.1 MBq (sd=48.1) for uw, nw and ow, respectively. Therefore, the total average NEC-p activity for the three BMI classes was 336.7 MBq (sd=40.7). The mean values of the radioactivity at a reduction of 1%, 3% and 5% with respect to the NEC-p were: 284.9 MBq (sd=40.7), 247.9 MBq (sd=33.3) and 225.7 MBq (sd=29.6) respectively. These results indicate the possibility to use, for the Discovery-ST, a single injection protocol of 448 MBq (for the range of BMI here considered) to have an activity at the acquisition time (after 45 min of uptake) of 336.7 MBq (NEC-p). Nevertheless, the plateau near the NEC-p suggests the possibility to reduce significantly the dose to be injected in clinical studies down to about 330 MBq, while preserving suitable NEC performance (-3%) with respect to the NEC-p. This result was supported by image quality assessment performed on reconstructed images of the NEMA 2001 IEC body phantom.
Cost of ownership for military cargo aircraft using a common versus disparate display configuration
NASA Astrophysics Data System (ADS)
Desjardins, Daniel D.; Most, Marvin C.
2010-04-01
A 2009 paper considered possibilities for applying a common display suite to various front-line bubble canopy fighters, whereas further research suggests the cost savings, post Milestone C production/deployment, might not be advantageous. The situation for military cargo and tanker aircraft, may offer a different paradigm. The primary objective of Defense acquisition is to acquire quality products that satisfy user needs with measurable improvements to mission capability and operational support, in a timely manner, and at a fair and reasonable price. DODD 5000.01 specifies that all participants in the acquisition system shall recognize the reality of fiscal constraints, viewing cost as an independent variable. DoD Components must therefore plan programs based on realistic projections of the dollars and manpower likely to be available in future years and also identify the total costs of ownership, as well as the major drivers of total ownership costs. In theory, therefore, this has already been done for existing cargo/tanker aircraft programs accommodating independent, disparate display suites. This paper goes beyond that stage by exploring total costs of ownership for a hypothetical common approach to cargo/tanker display avionics, bounded by looking at a limited number of such aircraft, e.g., C-5, C-17, C-130H (variants), and C-130J. It is the purpose of this paper to reveal whether there are total cost of ownership advantages for a common approach over and above the existing disparate approach. Aside from cost issues, other considerations, i.e., availability and supportability, may also be analyzed.
The image acquisition system design of floor grinder
NASA Astrophysics Data System (ADS)
Wang, Yang-jiang; Liu, Wei; Liu, Hui-qin
2018-01-01
Based on linear CCD, high resolution image real-time acquisition system serves as designing a set of image acquisition system for floor grinder through the calculation of optical imaging system. The entire image acquisition system can collect images of ground before and after the work of the floor grinder, and the data is transmitted through the Bluetooth system to the computer and compared to realize real-time monitoring of its working condition. The system provides technical support for the design of unmanned ground grinders.
Cho, JaeJin; Park, HyunWook
2018-05-17
To acquire interleaved bipolar data and reconstruct the full data using low-rank property for water fat separation. Bipolar acquisition suffers from issues related to gradient switching, the opposite gradient polarities, and other system imperfections, which prevent accurate water-fat separation. In this study, an interleaved bipolar acquisition scheme and a low-rank reconstruction method were proposed to reduce issues from the bipolar gradients while achieving a short imaging time. The proposed interleaved bipolar acquisition scheme collects echo-time signals from both gradient polarities; however, the sequence increases the imaging time. To reduce the imaging time, the signals were subsampled at every dimension of k-space. The low-rank property of the bipolar acquisition was defined and exploited to estimate the full data from the acquired subsampled data. To eliminate the bipolar issues, in the proposed method, the water-fat separation was performed separately for each gradient polarity, and the results for the positive and negative gradient polarities were combined after the water-fat separation. A phantom study and in-vivo experiments were conducted on a 3T Siemens Verio system. The results for the proposed method were compared with the results of the fully sampled interleaved bipolar acquisition and Soliman's method, which was the previous water-fat separation approach for reducing the issues of bipolar gradients and accelerating the interleaved bipolar acquisition. The proposed method provided accurate water and fat images without the issues of bipolar gradients and demonstrated a better performance compared with the results of the previous methods. The water-fat separation using the bipolar acquisition has several benefits including a short echo-spacing time. However, it suffers from bipolar-gradient issues such as strong gradient switching, system imperfection, and eddy current effects. This study demonstrated that accurate water-fat separated images can be obtained using the proposed interleaved bipolar acquisition and low-rank reconstruction by using the benefits of the bipolar acquisition while reducing the bipolar-gradient issues with a short imaging time. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
NASA Astrophysics Data System (ADS)
Bindschadler, Michael; Modgil, Dimple; Branch, Kelley R.; La Riviere, Patrick J.; Alessio, Adam M.
2014-04-01
Myocardial blood flow (MBF) can be estimated from dynamic contrast enhanced (DCE) cardiac CT acquisitions, leading to quantitative assessment of regional perfusion. The need for low radiation dose and the lack of consensus on MBF estimation methods motivates this study to refine the selection of acquisition protocols and models for CT-derived MBF. DCE cardiac CT acquisitions were simulated for a range of flow states (MBF = 0.5, 1, 2, 3 ml (min g)-1, cardiac output = 3, 5, 8 L min-1). Patient kinetics were generated by a mathematical model of iodine exchange incorporating numerous physiological features including heterogenenous microvascular flow, permeability and capillary contrast gradients. CT acquisitions were simulated for multiple realizations of realistic x-ray flux levels. CT acquisitions that reduce radiation exposure were implemented by varying both temporal sampling (1, 2, and 3 s sampling intervals) and tube currents (140, 70, and 25 mAs). For all acquisitions, we compared three quantitative MBF estimation methods (two-compartment model, an axially-distributed model, and the adiabatic approximation to the tissue homogeneous model) and a qualitative slope-based method. In total, over 11 000 time attenuation curves were used to evaluate MBF estimation in multiple patient and imaging scenarios. After iodine-based beam hardening correction, the slope method consistently underestimated flow by on average 47.5% and the quantitative models provided estimates with less than 6.5% average bias and increasing variance with increasing dose reductions. The three quantitative models performed equally well, offering estimates with essentially identical root mean squared error (RMSE) for matched acquisitions. MBF estimates using the qualitative slope method were inferior in terms of bias and RMSE compared to the quantitative methods. MBF estimate error was equal at matched dose reductions for all quantitative methods and range of techniques evaluated. This suggests that there is no particular advantage between quantitative estimation methods nor to performing dose reduction via tube current reduction compared to temporal sampling reduction. These data are important for optimizing implementation of cardiac dynamic CT in clinical practice and in prospective CT MBF trials.
Versatile synchronized real-time MEG hardware controller for large-scale fast data acquisition.
Sun, Limin; Han, Menglai; Pratt, Kevin; Paulson, Douglas; Dinh, Christoph; Esch, Lorenz; Okada, Yoshio; Hämäläinen, Matti
2017-05-01
Versatile controllers for accurate, fast, and real-time synchronized acquisition of large-scale data are useful in many areas of science, engineering, and technology. Here, we describe the development of a controller software based on a technique called queued state machine for controlling the data acquisition (DAQ) hardware, continuously acquiring a large amount of data synchronized across a large number of channels (>400) at a fast rate (up to 20 kHz/channel) in real time, and interfacing with applications for real-time data analysis and display of electrophysiological data. This DAQ controller was developed specifically for a 384-channel pediatric whole-head magnetoencephalography (MEG) system, but its architecture is useful for wide applications. This controller running in a LabVIEW environment interfaces with microprocessors in the MEG sensor electronics to control their real-time operation. It also interfaces with a real-time MEG analysis software via transmission control protocol/internet protocol, to control the synchronous acquisition and transfer of the data in real time from >400 channels to acquisition and analysis workstations. The successful implementation of this controller for an MEG system with a large number of channels demonstrates the feasibility of employing the present architecture in several other applications.
Versatile synchronized real-time MEG hardware controller for large-scale fast data acquisition
NASA Astrophysics Data System (ADS)
Sun, Limin; Han, Menglai; Pratt, Kevin; Paulson, Douglas; Dinh, Christoph; Esch, Lorenz; Okada, Yoshio; Hämäläinen, Matti
2017-05-01
Versatile controllers for accurate, fast, and real-time synchronized acquisition of large-scale data are useful in many areas of science, engineering, and technology. Here, we describe the development of a controller software based on a technique called queued state machine for controlling the data acquisition (DAQ) hardware, continuously acquiring a large amount of data synchronized across a large number of channels (>400) at a fast rate (up to 20 kHz/channel) in real time, and interfacing with applications for real-time data analysis and display of electrophysiological data. This DAQ controller was developed specifically for a 384-channel pediatric whole-head magnetoencephalography (MEG) system, but its architecture is useful for wide applications. This controller running in a LabVIEW environment interfaces with microprocessors in the MEG sensor electronics to control their real-time operation. It also interfaces with a real-time MEG analysis software via transmission control protocol/internet protocol, to control the synchronous acquisition and transfer of the data in real time from >400 channels to acquisition and analysis workstations. The successful implementation of this controller for an MEG system with a large number of channels demonstrates the feasibility of employing the present architecture in several other applications.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Use. 9.303 Section 9.303 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION ACQUISITION PLANNING CONTRACTOR... or specifications; (2) Production has been discontinued for an extended period of time; or (3) The...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 1 2014-10-01 2014-10-01 false Use. 9.303 Section 9.303 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION ACQUISITION PLANNING CONTRACTOR... or specifications; (2) Production has been discontinued for an extended period of time; or (3) The...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Use. 9.303 Section 9.303 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION ACQUISITION PLANNING CONTRACTOR... or specifications; (2) Production has been discontinued for an extended period of time; or (3) The...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Use. 9.303 Section 9.303 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION ACQUISITION PLANNING CONTRACTOR... or specifications; (2) Production has been discontinued for an extended period of time; or (3) The...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Use. 9.303 Section 9.303 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION ACQUISITION PLANNING CONTRACTOR... or specifications; (2) Production has been discontinued for an extended period of time; or (3) The...
Environmental Life Cycle Techniques for New Weapons Acquisition Systems
2004-09-01
Amount) Total grenade War Caracterisation factors (MJ/nn) Unit (Impact indicator) Total grenade War Total of all compartments MJ 59200 82700... Caracterisation factors (Kg CFC11 eq/nn) Unit (Impact indicator) Total grenade War Total of all compartments kg CFC-11 0,000429 0,00046 Remaining...Substance Compartment Unit (Amount) Total grenade War Caracterisation factors (Kg C2H2/nn) Unit (Impact indicator) Total grenade War Total of all
Response Acquisition and Fixed-Ratio Escalation Based on Interresponse Times in Rats
ERIC Educational Resources Information Center
Taylor, Tracy G.; Galuska, Chad M.; Banna, Kelly; Yahyavi-Firouz-Abadi, Noushin; See, Ronald E.
2010-01-01
The effectiveness of a fixed-ratio (FR) escalation procedure, developed by Pinkston and Branch (2004) and based on interresponse times (IRTs), was assessed during lever-press acquisition. Forty-nine experimentally naive adult male Long Evans rats were deprived of food for 24 hr prior to an extended acquisition session. Before the start of the…
Verb Particle and Preposition Acquisition in Language-Impaired Preschoolers.
ERIC Educational Resources Information Center
Watkins, Ruth V.; Rice, Mabel L.
1991-01-01
This study examined the acquisition of verb particles and prepositions in language-impaired, language-matched, and age-matched preschool children (total n=42). Results indicated that the use of verb particles constituted a particularly challenging task for the language-impaired subjects relative to both the age-matched and language-matched peers.…
48 CFR 1852.228-82 - Insurance-Total Immunity From Tort Liability.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Insurance-Total Immunity... Provisions and Clauses 1852.228-82 Insurance—Total Immunity From Tort Liability. As prescribed in 1828.311-270(d), insert the following clause: Insurance—Total Immunity From Tort Liability (SEP 2000) (a) The...
48 CFR 1852.228-82 - Insurance-Total Immunity From Tort Liability.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Insurance-Total Immunity... Provisions and Clauses 1852.228-82 Insurance—Total Immunity From Tort Liability. As prescribed in 1828.311-270(d), insert the following clause: Insurance—Total Immunity From Tort Liability (SEP 2000) (a) The...
48 CFR 1852.228-82 - Insurance-Total Immunity From Tort Liability.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Insurance-Total Immunity... Provisions and Clauses 1852.228-82 Insurance—Total Immunity From Tort Liability. As prescribed in 1828.311-270(d), insert the following clause: Insurance—Total Immunity From Tort Liability (SEP 2000) (a) The...
48 CFR 1852.228-82 - Insurance-Total Immunity From Tort Liability.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Insurance-Total Immunity... Provisions and Clauses 1852.228-82 Insurance—Total Immunity From Tort Liability. As prescribed in 1828.311-270(d), insert the following clause: Insurance—Total Immunity From Tort Liability (SEP 2000) (a) The...
48 CFR 1852.228-82 - Insurance-Total Immunity From Tort Liability.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false Insurance-Total Immunity... Provisions and Clauses 1852.228-82 Insurance—Total Immunity From Tort Liability. As prescribed in 1828.311-270(d), insert the following clause: Insurance—Total Immunity From Tort Liability (SEP 2000) (a) The...
48 CFR 819.502-2 - Total small business set-asides.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Total small business set... SOCIOECONOMIC PROGRAMS SMALL BUSINESS PROGRAMS Set-Asides for Small Business 819.502-2 Total small business set-asides. (a) When a total small business set-aside is made, one of the following statements, as applicable...
48 CFR 819.502-2 - Total small business set-asides.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Total small business set... SOCIOECONOMIC PROGRAMS SMALL BUSINESS PROGRAMS Set-Asides for Small Business 819.502-2 Total small business set-asides. (a) When a total small business set-aside is made, one of the following statements, as applicable...
48 CFR 819.502-2 - Total small business set-asides.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 5 2013-10-01 2013-10-01 false Total small business set... SOCIOECONOMIC PROGRAMS SMALL BUSINESS PROGRAMS Set-Asides for Small Business 819.502-2 Total small business set-asides. (a) When a total small business set-aside is made, one of the following statements, as applicable...
48 CFR 819.502-2 - Total small business set-asides.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Total small business set... SOCIOECONOMIC PROGRAMS SMALL BUSINESS PROGRAMS Set-Asides for Small Business 819.502-2 Total small business set-asides. (a) When a total small business set-aside is made, one of the following statements, as applicable...
48 CFR 819.502-2 - Total small business set-asides.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 5 2012-10-01 2012-10-01 false Total small business set... SOCIOECONOMIC PROGRAMS SMALL BUSINESS PROGRAMS Set-Asides for Small Business 819.502-2 Total small business set-asides. (a) When a total small business set-aside is made, one of the following statements, as applicable...
48 CFR 46.707 - Pricing aspects of fixed-price incentive contract warranties.
Code of Federal Regulations, 2010 CFR
2010-10-01
... FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT QUALITY ASSURANCE Warranties 46.707 Pricing aspects of... the total final price. Contractor compliance with the warranty after the establishment of the total...
48 CFR 46.707 - Pricing aspects of fixed-price incentive contract warranties.
Code of Federal Regulations, 2011 CFR
2011-10-01
... FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT QUALITY ASSURANCE Warranties 46.707 Pricing aspects of... the total final price. Contractor compliance with the warranty after the establishment of the total...
Kerri T. Vierling; Charles E. Swift; Andrew T. Hudak; Jody C. Vogeler; Lee A. Vierling
2014-01-01
Vegetation structure quantified by light detection and ranging (LiDAR) can improve understanding of wildlife occupancy and species-richness patterns. However, there is often a time lag between the collection of LiDAR data and wildlife data. We investigated whether a time lag between the LiDAR acquisition and field-data acquisition affected mapped wildlife distributions...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perdian, D. C.; Lee, Young Jin
2010-11-15
A novel mass spectrometric imaging method is developed to reduce the data acquisition time and provide rich chemical information using a hybrid linear ion trap-orbitrap mass spectrometer. In this method, the linear ion trap and orbitrap are used in tandem to reduce the acquisition time by incorporating multiple linear ion trap scans during an orbitrap scan utilizing a spiral raster step plate movement. The data acquisition time was decreased by 43-49% in the current experiment compared to that of orbitrap-only scans; however, 75% or more time could be saved for higher mass resolution and with a higher repetition rate laser.more » Using this approach, a high spatial resolution of 10 {micro}m was maintained at ion trap imaging, while orbitrap spectra were acquired at a lower spatial resolution, 20-40 {micro}m, all with far less data acquisition time. Furthermore, various MS imaging methods were developed by interspersing MS/MS and MSn ion trap scans during orbitrap scans to provide more analytical information on the sample. This method was applied to differentiate and localize structural isomers of several flavonol glycosides from an Arabidopsis flower petal in which MS/MS, MSn, ion trap, and orbitrap images were all acquired in a single data acquisition.« less
Faure, Marguerite E; Swart, Laurens E; Dijkshoorn, Marcel L; Bekkers, Jos A; van Straten, Marcel; Nieman, Koen; Parizel, Paul M; Krestin, Gabriel P; Budde, Ricardo P J
2018-05-01
Multidetector CT (MDCT) is a valuable tool for functional prosthetic heart valve (PHV) assessment. However, radiation exposure remains a concern. We assessed a novel CT-acquisition protocol for comprehensive PHV evaluation at limited dose. Patients with a PHV were scanned using a third-generation dual-source CT scanner (DSCT) and iterative reconstruction technique (IR). Three acquisitions were obtained: a non-enhanced scan; a contrast-enhanced, ECG-triggered, arterial CT angiography (CTA) scan with reconstructions at each 5 % of the R-R interval; and a delayed high-pitch CTA of the entire chest. Image quality was scored on a five-point scale. Radiation dose was obtained from the reported CT dose index (CTDI) and dose length product (DLP). We analysed 43 CT examinations. Mean image quality score was 4.1±1.4, 4.7±0.5 and 4.2±0.6 for the non-contrast-enhanced, arterial and delayed acquisitions, respectively, with a total mean image quality of 4.3±0.7. Mean image quality for leaflet motion was 3.9±1.4. Mean DLP was 28.2±17.1, 457.3±168.6 and 68.5±47.2 mGy.cm for the non-contrast-enhanced (n=40), arterial (n=43) and delayed acquisition (n=43), respectively. The mean total DLP was 569±208 mGy.cm and mean total radiation dose was 8.3±3.0 mSv (n=43). Comprehensive assessment of PHVs is possible using DSCT and IR at moderate radiation dose. • Prosthetic heart valve dysfunction is a potentially life-threatening condition. • Dual-source CT can adequately assess valve leaflet motion and anatomy. • We assessed a comprehensive protocol with three acquisitions for PHV evaluation. • This protocol is associated with good image quality and limited dose.
Oldrini, Guillaume; Fedida, Benjamin; Poujol, Julie; Felblinger, Jacques; Trop, Isabelle; Henrot, Philippe; Darai, Emile; Thomassin-Naggara, Isabelle
2017-10-01
To evaluate the added value of ULTRAFAST-MR sequence to an abbreviated FAST protocol in comparison with FULL protocol to distinguish benign from malignant lesions in a population of women, regardless of breast MR imaging indication. From March 10th to September 22th, 2014, we retrospectively included a total of 70 consecutive patients with 106 histologically proven lesions (58 malignant and 48 benign) who underwent breast MR imaging for preoperative breast staging (n=38), high-risk screening (n=7), problem solving (n=18), and nipple discharge (n=4) with 12 time resolved imaging of contrast kinetics (TRICKS) acquisitions during contrast inflow interleaved in a regular high-resolution dynamic MRI protocol (FULL protocol). Two readers scored MR exams as either positive or negative and described significant lesions according to Bi-RADS lexicon with a TRICKS images (ULTRAFAST), an abbreviated protocol (FAST) and all images (FULL protocol). Sensitivity, specificity, positive and negative predictive values, and accuracy were calculated for each protocol and compared with McNemar's test. For all readers, the combined FAST-ULTRAFAST protocol significantly improved the reading with a specificity of 83.3% and 70.8% in comparison with FAST protocol or FULL protocol, respectively, without change in sensitivity. By adding ULTRAFAST protocol to FAST protocol, readers 1 and 2 were able to correctly change the diagnosis in 22.9% (11/48) and 10.4% (5/48) of benign lesions, without missing any malignancy, respectively. Both interpretation and image acquisition times for combined FAST-ULTRAFAST protocol and FAST protocol were shorter compared to FULL protocol (p<0.001). Compared to FULL protocol, adding ULTRAFAST to FAST protocol improves specificity, mainly in correctly reclassifying benign masses and reducing interpretation and acquisition time, without decreasing sensitivity. Copyright © 2017 Elsevier B.V. All rights reserved.
Relaxation time estimation in surface NMR
Grunewald, Elliot D.; Walsh, David O.
2017-03-21
NMR relaxation time estimation methods and corresponding apparatus generate two or more alternating current transmit pulses with arbitrary amplitudes, time delays, and relative phases; apply a surface NMR acquisition scheme in which initial preparatory pulses, the properties of which may be fixed across a set of multiple acquisition sequence, are transmitted at the start of each acquisition sequence and are followed by one or more depth sensitive pulses, the pulse moments of which are varied across the set of multiple acquisition sequences; and apply processing techniques in which recorded NMR response data are used to estimate NMR properties and the relaxation times T.sub.1 and T.sub.2* as a function of position as well as one-dimensional and two-dimension distributions of T.sub.1 versus T.sub.2* as a function of subsurface position.
The hybrid UNIX controller for real-time data acquisition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huesman, R.H.; Klein, G.J.; Fleming, T.K.
1996-06-01
The authors describe a hybrid data acquisition architecture integrating a conventional UNIX workstation with CAMAC-based real-time hardware. The system combines the high-level programming simplicity and user interface of a UNIX workstation with the low-level timing control available from conventional real-time hardware. They detail this architecture as it has been implemented for control of the Donner 600-Crystal Positron Tomograph (PET600). Low-level data acquisition is carried out in this system using eight LeCroy 3588 histogrammers, which together after derandomization, acquire events at rates up to 4 MHz, and two dedicated Motorola 6809 microprocessors, which arbitrate fine timing control during acquisition. A SUNmore » Microsystems UNIX workstation is used for high-level control, allowing an easily extensible user interface in an X-Windows environment, as well as real-time communications to the low-level acquisition units. Communication between the high- and low-level units is carried out via a Jorway 73A SCSI-CAMAC crate controller and a serial interface. For this application, the hybrid configuration segments low from high-level control for ease of maintenance and provided a low-cost upgrade from dated high-level control hardware.« less
The automation of an inlet mass flow control system
NASA Technical Reports Server (NTRS)
Supplee, Frank; Tcheng, Ping; Weisenborn, Michael
1989-01-01
The automation of a closed-loop computer controlled system for the inlet mass flow system (IMFS) developed for a wind tunnel facility at Langley Research Center is presented. This new PC based control system is intended to replace the manual control system presently in use in order to fully automate the plug positioning of the IMFS during wind tunnel testing. Provision is also made for communication between the PC and a host-computer in order to allow total animation of the plug positioning and data acquisition during the complete sequence of predetermined plug locations. As extensive running time is programmed for the IMFS, this new automated system will save both manpower and tunnel running time.
NASA Technical Reports Server (NTRS)
Frost, J. D., Jr.; Salamy, J. G.
1973-01-01
The Skylab sleep-monitoring experiment simulated the timelines and environment expected during a 56-day Skylab mission. Two crewmembers utilized the data acquisition and analysis hardware, and their sleep characteristics were studied in an online fashion during a number of all night recording sessions. Comparison of the results of online automatic analysis with those of postmission visual data analysis was favorable, confirming the feasibility of obtaining reliable objective information concerning sleep characteristics during the Skylab missions. One crewmember exhibited definite changes in certain sleep characteristics (e.g., increased sleep latency, increased time Awake during first third of night, and decreased total sleep time) during the mission.
Code of Federal Regulations, 2010 CFR
2010-10-01
...-Materials/Labor-Hour Proposal Requirements-Non-Commercial Item Acquisition With Adequate Price Competition... Requirements—Non-Commercial Item Acquisition With Adequate Price Competition. As prescribed in 216.601(e...-and-Materials/Labor-Hour Proposal Requirements—Non-Commercial Item Acquisition With Adequate Price...
Rodriguez-Luna, David; Dowlatshahi, Dar; Aviv, Richard I; Molina, Carlos A; Silva, Yolanda; Dzialowski, Imanuel; Lum, Cheemun; Czlonkowska, Anna; Boulanger, Jean-Martin; Kase, Carlos S; Gubitz, Gord; Bhatia, Rohit; Padma, Vasantha; Roy, Jayanta; Stewart, Teri; Huynh, Thien J; Hill, Michael D; Demchuk, Andrew M
2014-03-01
Variability in computed tomography angiography (CTA) acquisitions may be one explanation for the modest accuracy of the spot sign for predicting intracerebral hemorrhage expansion detected in the multicenter Predicting Hematoma Growth and Outcome in Intracerebral Hemorrhage Using Contrast Bolus CT (PREDICT) study. This study aimed to determine the frequency of the spot sign in intracerebral hemorrhage and its relationship with hematoma expansion depending on the phase of image acquisition. PREDICT study was a prospective observational cohort study of patients with intracerebral hemorrhage presenting within 6 hours from onset. A post hoc analysis of the Hounsfield units of an artery and venous structure were measured on CTA source images of the entire PREDICT cohort in a core laboratory. Each CTA study was classified into arterial or venous phase and into 1 of 5 specific image acquisition phases. Significant hematoma expansion and total hematoma enlargement were recorded at 24 hours. Overall (n=371), 77.9% of CTA were acquired in arterial phase. The spot sign, present in 29.9% of patients, was more frequently seen in venous phase as compared with arterial phase (39% versus 27.3%; P=0.041) and the later the phase of image acquisition (P=0.095). Significant hematoma expansion (P=0.253) and higher total hematoma enlargement (P=0.019) were observed more frequently among spot sign-positive patients with earlier phases of image acquisition. Later image acquisition of CTA improves the frequency of spot sign detection. However, spot signs identified in earlier phases may be associated with greater absolute enlargement. A multiphase CTA including arterial and venous acquisitions could be optimal in patients with intracerebral hemorrhage.
Perry, Jennifer L.; Anderson, Marissa M.; Nelson, Sarah E.; Carroll, Marilyn E.
2009-01-01
Adolescence and excessive intake of saccharin have each been previously associated with enhanced vulnerability to drug abuse. In the present study, we focused on the relationship between these two factors using male adolescent and adult rats bred for high (HiS) and low (LoS) levels of saccharin intake. On postnatal day 25 (adolescents) or 150 (adults), rats were implanted with an intravenous catheter and trained to self-administer cocaine (0.4 mg/kg) using an autoshaping procedure that consisted of two 6-h sessions. In the first 6 h, rats were given noncontingent cocaine infusions at random intervals 10 times per hour, and during the second 6-h session, rats were allowed to self-administer cocaine under a fixed ratio 1 (FR 1) lever-response contingency. Acquisition was defined as a total of at least 250 infusions over 5 consecutive days, and rats were given 30 days to meet the acquisition criterion. Subsequently, saccharin intake was determined by comparing 24-h saccharin and water consumption in two-bottle tests. Adolescent LoS rats had a faster rate of acquisition of cocaine self-administration than adult LoS rats; however, adolescent and adult HiS rats acquired at the same rate. Both HiS and LoS adolescents had significantly higher saccharin preference scores than HiS and LoS adults, respectively. Additionally, saccharin score was negatively correlated with the number of days to meet the acquisition criterion for cocaine self-administration, but this was mostly accounted for by the HiS adolescents. These results suggest that during adolescence, rats have both an increased avidity for sweets and vulnerability to initiate drug abuse compared with adulthood. PMID:17360010
Perry, Jennifer L; Anderson, Marissa M; Nelson, Sarah E; Carroll, Marilyn E
2007-05-16
Adolescence and excessive intake of saccharin have each been previously associated with enhanced vulnerability to drug abuse. In the present study, we focused on the relationship between these two factors using male adolescent and adult rats selectively bred for high (HiS) and low (LoS) levels of saccharin intake. On postnatal day 25 (adolescents) or 150 (adults), rats were implanted with an intravenous catheter and trained to self-administer cocaine (0.4 mg/kg) using an autoshaping procedure that consisted of two 6-h sessions. In the first 6 h, rats were given non-contingent cocaine infusions at random intervals 10 times per hour, and during the second 6-h session, rats were allowed to self-administer cocaine under a fixed ratio 1 (FR 1) lever-response contingency. Acquisition was defined as a total of at least 250 infusions over 5 consecutive days, and rats were given 30 days to meet the acquisition criterion. Subsequently, saccharin phenotype scores were determined by comparing 24-h saccharin and water consumption in two-bottle tests to verify HiS/LoS status. Adolescent LoS rats had a faster rate of acquisition of cocaine self-administration than adult LoS rats; however, adolescent and adult HiS rats acquired at the same rate. Both HiS and LoS adolescents had significantly higher saccharin phenotype scores than HiS and LoS adults, respectively. Additionally, saccharin score was negatively correlated with the number of days to meet the acquisition criterion for cocaine self-administration, but this was mostly accounted for by the HiS adolescents. These results suggest that during adolescence, compared with adulthood, rats have both an increased avidity for sweets and vulnerability to initiate drug abuse.
NASA Astrophysics Data System (ADS)
Chen, R.; Xi, X.; Zhao, X.; He, L.; Yao, H.; Shen, R.
2016-12-01
Dense 3D magnetotelluric (MT) data acquisition owns the benefit of suppressing the static shift and topography effect, can achieve high precision and high resolution inversion for underground structure. This method may play an important role in mineral exploration, geothermal resources exploration, and hydrocarbon exploration. It's necessary to reduce the power consumption greatly of a MT signal receiver for large-scale 3D MT data acquisition while using sensor network to monitor data quality of deployed MT receivers. We adopted a series of technologies to realized above goal. At first, we designed an low-power embedded computer which can couple with other parts of MT receiver tightly and support wireless sensor network. The power consumption of our embedded computer is less than 1 watt. Then we designed 4-channel data acquisition subsystem which supports 24-bit analog-digital conversion, GPS synchronization, and real-time digital signal processing. Furthermore, we developed the power supply and power management subsystem for MT receiver. At last, a series of software, which support data acquisition, calibration, wireless sensor network, and testing, were developed. The software which runs on personal computer can monitor and control over 100 MT receivers on the field for data acquisition and quality control. The total power consumption of the receiver is about 2 watts at full operation. The standby power consumption is less than 0.1 watt. Our testing showed that the MT receiver can acquire good quality data at ground with electrical dipole length as 3 m. Over 100 MT receivers were made and used for large-scale geothermal exploration in China with great success.
Pradhan, Mr; Taylor, Fc; Agrawal, S; Prabhakaran, D; Ebrahim, S
2013-12-01
Food habits and choices in India are shifting due to many factors: changing food markets, fast urbanization, food price inflation, uncertain food production and unequal distribution during the past decade. This study aims to explore food acquisition and intra-household consumption patterns in urban low and middle income (LMI) households in Delhi. Twenty households were randomly selected from the Center for Cardio-metabolic Risk Reduction in South Asia (CARRS) surveillance study. Data were derived from 20 questionnaires administered to women responsible for food preparation, four key-informant-interviews, and 20 in-depth interviews with household heads during September-November 2011. STATA and ATLAS.ti software were used for data analysis. Half of the households spent at least two-thirds of their income on food. The major expenditures were on vegetables (22% of total food expenditure), milk and milk products (16%), and cereal and related products (15%). Income, food prices, food preferences, and seasonal variation influenced food expenditure. Adults usually ate two to three times a day while children ate more frequently. Eating sequence was based on the work pattern within the household and cultural beliefs. Contrary to previous evidence, there was no gender bias in intra-household food distribution. Women considered food acquisition, preparation and distribution part of their self-worth and played a major role in food related issues in the household. Women's key roles in food acquisition, preparation and intra household food consumption should be considered in formulating food policies and programs.
The Attitude Determination Scale for Value Acquisition: A Validity and Reliability Study
ERIC Educational Resources Information Center
Cetin, Saban
2017-01-01
This study aims to develop a measurement tool having measurement reliability with the aim of determining attitudes for values acquisition of secondary school students. The study was conducted on totally 325 high school senior students as 200 female and 125 male students in spring semester of 2014-2015 educational year. In the study, expert opinion…
Improving the Acquisition of Novel Vocabulary through the Use of Imagery Interventions
ERIC Educational Resources Information Center
Cohen, Marisa T.; Johnson, Helen L.
2011-01-01
The purpose of this study was to investigate the impact of imagery interventions on the vocabulary acquisition abilities of second grade students. A total of 15 students were randomly assigned to three different intervention conditions: Word Only, which involves the simple verbal presentation of a vocabulary word; Dual Coding, in which a picture…
Prosodic Awareness Skills and Literacy Acquisition in Spanish
ERIC Educational Resources Information Center
Defior, Sylvia; Gutierrez-Palma, Nicolas; Cano-Marin, Maria Jose
2012-01-01
There has been very little research in Spanish on the potential role of prosodic skills in reading and spelling acquisition, which is the subject of the present study. A total of 85 children in 5th year of Primary Education (mean age 10 years and 9 months) performed tests assessing memory, stress awareness, phonological awareness, reading and…
Aspects of Western Refining, Inc.'s Proposed Acquisition of Giant Industries, Inc.
2006-01-01
Presentation of company-level, non-proprietary data and relevant aggregate data for U.S. refinery capacity and gasoline marketing of Western Refining and Giant Industries to inform discussions of Western Refining Inc.'s proposed acquisition of Giant Industries Inc. for a total of $1.5 billion, which was announced August 28, 2006.
Visual Skills and Chinese Reading Acquisition: A Meta-Analysis of Correlation Evidence
ERIC Educational Resources Information Center
Yang, Ling-Yan; Guo, Jian-Peng; Richman, Lynn C.; Schmidt, Frank L.; Gerken, Kathryn C.; Ding, Yi
2013-01-01
This paper used meta-analysis to synthesize the relation between visual skills and Chinese reading acquisition based on the empirical results from 34 studies published from 1991 to 2011. We obtained 234 correlation coefficients from 64 independent samples, with a total of 5,395 participants. The meta-analysis revealed that visual skills as a…
Microcomputer data acquisition and control.
East, T D
1986-01-01
In medicine and biology there are many tasks that involve routine well defined procedures. These tasks are ideal candidates for computerized data acquisition and control. As the performance of microcomputers rapidly increases and cost continues to go down the temptation to automate the laboratory becomes great. To the novice computer user the choices of hardware and software are overwhelming and sadly most of the computer sales persons are not at all familiar with real-time applications. If you want to bill your patients you have hundreds of packaged systems to choose from; however, if you want to do real-time data acquisition the choices are very limited and confusing. The purpose of this chapter is to provide the novice computer user with the basics needed to set up a real-time data acquisition system with the common microcomputers. This chapter will cover the following issues necessary to establish a real time data acquisition and control system: Analysis of the research problem: Definition of the problem; Description of data and sampling requirements; Cost/benefit analysis. Choice of Microcomputer hardware and software: Choice of microprocessor and bus structure; Choice of operating system; Choice of layered software. Digital Data Acquisition: Parallel Data Transmission; Serial Data Transmission; Hardware and software available. Analog Data Acquisition: Description of amplitude and frequency characteristics of the input signals; Sampling theorem; Specification of the analog to digital converter; Hardware and software available; Interface to the microcomputer. Microcomputer Control: Analog output; Digital output; Closed-Loop Control. Microcomputer data acquisition and control in the 21st Century--What is in the future? High speed digital medical equipment networks; Medical decision making and artificial intelligence.
Fernández-Coello, Alejandro; Havas, Viktória; Juncadella, Montserrat; Sierpowska, Joanna; Rodríguez-Fornells, Antoni; Gabarrós, Andreu
2017-06-01
OBJECTIVE Most knowledge regarding the anatomical organization of multilingualism is based on aphasiology and functional imaging studies. However, the results have still to be validated by the gold standard approach, namely electrical stimulation mapping (ESM) during awake neurosurgical procedures. In this ESM study the authors describe language representation in a highly specific group of 13 multilingual individuals, focusing on how age of acquisition may influence the cortical organization of language. METHODS Thirteen patients who had a high degree of proficiency in multiple languages and were harboring lesions within the dominant, left hemisphere underwent ESM while being operated on under awake conditions. Demographic and language data were recorded in relation to age of language acquisition (for native languages and early- and late-acquired languages), neuropsychological pre- and postoperative language testing, the number and location of language sites, and overlapping distribution in terms of language acquisition time. Lesion growth patterns and histopathological characteristics, location, and size were also recorded. The distribution of language sites was analyzed with respect to age of acquisition and overlap. RESULTS The functional language-related sites were distributed in the frontal (55%), temporal (29%), and parietal lobes (16%). The total number of native language sites was 47. Early-acquired languages (including native languages) were represented in 97 sites (55 overlapped) and late-acquired languages in 70 sites (45 overlapped). The overlapping distribution was 20% for early-early, 71% for early-late, and 9% for late-late. The average lesion size (maximum diameter) was 3.3 cm. There were 5 fast-growing and 7 slow-growing lesions. CONCLUSIONS Cortical language distribution in multilingual patients is not homogeneous, and it is influenced by age of acquisition. Early-acquired languages have a greater cortical representation than languages acquired later. The prevalent native and early-acquired languages are largely represented within the perisylvian left hemisphere frontoparietotemporal areas, and the less prevalent late-acquired languages are mostly overlapped with them.
Jahn, Georg; Krems, Josef F; Gelau, Christhard
2009-04-01
This study tested whether the ease of learning to use human-machine interfaces of in-vehicle information systems (IVIS) can be assessed at standstill. Assessing the attentional demand of IVIS should include an evaluation of ease of learning, because the use of IVIS at low skill levels may create safety-relevant distractions. Skill acquisition in operating IVIS was quantified by fitting the power law of practice to training data sets collected in a driving study and at standstill. Participants practiced manual destination entry with two route guidance systems differing in cognitive demand. In Experiment 1, a sample of middle-aged participants was trained while steering routes of varying driving demands. In Experiment 2, another sample of middle-aged participants was trained at standstill. In Experiment 1, display glance times were less affected by driving demands than by total task times and decreased at slightly higher speed-up rates (0.02 higher on average) than task times collected at standstill in Experiment 2. The system interface that minimized cognitive demand was operated more quickly and was easier to learn. Its system delays increased static task times, which still predicted 58% of variance in display glance times compared with even 76% for the second system. The ease of learning to use an IVIS interface and the decrease in attentional demand with training can be assessed at standstill. Fitting the power law of practice to static task times yields parameters that predict display glance times while driving, which makes it possible to compare interfaces with regard to ease of learning.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-21
...-AM55 Federal Acquisition Regulation; Ending Trafficking in Persons; Extension of Time for Comments... comment period is being extended to provide additional time for interested parties to provide comments for... 78 FR 59317, September 26, 2013. The comment period is extended to provide additional time for...
Minimalism and Beyond: Second Language Acquisition for the Twenty-First Century.
ERIC Educational Resources Information Center
Balcom, Patricia A.
2001-01-01
Provides a general overview of two books--"The Second Time Around: Minimalism and Second Language Acquisition" and "Second Language Syntax: A Generative Introduction--and shows how the respond to key issues in second language acquisition, including the process of second language acquisition, access to universal grammar, the role of…
Aviation Acquisition: A Comprehensive Strategy Is Needed for Cultural Change at FAA
DOT National Transportation Integrated Search
1996-08-22
The Federal Aviation Administration's (FAA) timely acquisition of new air : traffic control equipment has become increasingly critical for aviation safety : and efficiency. However, persistent acquisition problems raise questions about : the agency's...
Extending single molecule fluorescence observation time by amplitude-modulated excitation
Kisley, Lydia; Chang, Wei-Shun; Cooper, David; Mansur, Andrea P; Landes, Christy F
2014-01-01
We present a hardware-based method that can improve single molecule fluorophore observation time by up to 1500% and super-localization by 47% for the experimental conditions used. The excitation was modulated using an acousto-optic modulator (AOM) synchronized to the data acquisition and inherent data conversion time of the detector. The observation time and precision in super-localization of four commonly used fluorophores were compared under modulated and traditional continuous excitation, including direct total internal reflectance excitation of Alexa 555 and Cy3, non-radiative Förster resonance energy transfer (FRET) excited Cy5, and direct epi-fluorescence wide field excitation of Rhodamine 6G. The proposed amplitude-modulated excitation does not perturb the chemical makeup of the system or sacrifice signal and is compatible with multiple types of fluorophores. Amplitude-modulated excitation has practical applications for any fluorescent study utilizing an instrumental setup with time-delayed detectors. PMID:24587894
48 CFR 47.207-2 - Duration of contract and time of performance.
Code of Federal Regulations, 2010 CFR
2010-10-01
... time of performance. 47.207-2 Section 47.207-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT TRANSPORTATION Contracts for Transportation or for Transportation-Related Services 47.207-2 Duration of contract and time of performance. The contracting officer shall— (a...
Keat, Chan Huan; Ghani, Norazila Abdul
2013-01-01
In a prospective cohort study of antiemetic therapy conducted in Malaysia, a total of 94 patients received low emetogenic chemotherapy (LEC) with or without granisetron injections as the primary prophylaxis for chemotherapy-induced nausea and vomiting (CINV). This study is a retrospective cost analysis of two antiemetic regimens from the payer perspective. This cost evaluation refers to 2011, the year in which the observation was conducted. Direct costs incurred by hospitals including the drug acquisition, materials and time spent for clinical activities from prescribing to dispensing of home medications were evaluated (MYR 1=$0.32 USD). As reported to be significantly different between two regimens (96.1% vs 81.0%; p=0.017), the complete response rate of acute emesis which was defined as a patient successfully treated without any emesis episode within 24 hours after LEC was used as the main indicator for effectiveness. Antiemetic drug acquisition cost per patient was 40.7 times higher for the granisetron-based regimen than for the standard regimen (MYR 64.3 vs 1.58). When both the costs for materials and clinical activities were included, the total cost per patient was 8.68 times higher for the granisetron-based regimen (MYR 73.5 vs 8.47). Considering the complete response rates, the mean cost per successfully treated patient in granisetron group was 7.31 times higher (MYR 76.5 vs 10.5). The incremental cost-effectiveness ratio (ICER) with granisetron-based regimen, relative to the standard regimen, was MYR 430.7. It was found to be most sensitive to the change of antiemetic effects of granisetron-based regimen. While providing a better efficacy in acute emesis control, the low incidence of acute emesis and high ICER makes use of granisetron as primary prophylaxis in LEC controversial.
Artifact Noise Removal Techniques on Seismocardiogram Using Two Tri-Axial Accelerometers
Luu, Loc; Dinh, Anh
2018-01-01
The aim of this study is on the investigation of motion noise removal techniques using two-accelerometer sensor system and various placements of the sensors on gentle movement and walking of the patients. A Wi-Fi based data acquisition system and a framework on Matlab are developed to collect and process data while the subjects are in motion. The tests include eight volunteers who have no record of heart disease. The walking and running data on the subjects are analyzed to find the minimal-noise bandwidth of the SCG signal. This bandwidth is used to design filters in the motion noise removal techniques and peak signal detection. There are two main techniques of combining signals from the two sensors to mitigate the motion artifact: analog processing and digital processing. The analog processing comprises analog circuits performing adding or subtracting functions and bandpass filter to remove artifact noises before entering the data acquisition system. The digital processing processes all the data using combinations of total acceleration and z-axis only acceleration. The two techniques are tested on three placements of accelerometer sensors including horizontal, vertical, and diagonal on gentle motion and walking. In general, the total acceleration and z-axis acceleration are the best techniques to deal with gentle motion on all sensor placements which improve average systolic signal-noise-ratio (SNR) around 2 times and average diastolic SNR around 3 times comparing to traditional methods using only one accelerometer. With walking motion, ADDER and z-axis acceleration are the best techniques on all placements of the sensors on the body which enhance about 7 times of average systolic SNR and about 11 times of average diastolic SNR comparing to only one accelerometer method. Among the sensor placements, the performance of horizontal placement of the sensors is outstanding comparing with other positions on all motions. PMID:29614821
Statistical analysis of low-voltage EDS spectrum images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, I.M.
1998-03-01
The benefits of using low ({le}5 kV) operating voltages for energy-dispersive X-ray spectrometry (EDS) of bulk specimens have been explored only during the last few years. This paper couples low-voltage EDS with two other emerging areas of characterization: spectrum imaging of a computer chip manufactured by a major semiconductor company. Data acquisition was performed with a Philips XL30-FEG SEM operated at 4 kV and equipped with an Oxford super-ATW detector and XP3 pulse processor. The specimen was normal to the electron beam and the take-off angle for acquisition was 35{degree}. The microscope was operated with a 150 {micro}m diameter finalmore » aperture at spot size 3, which yielded an X-ray count rate of {approximately}2,000 s{sup {minus}1}. EDS spectrum images were acquired as Adobe Photoshop files with the 4pi plug-in module. (The spectrum images could also be stored as NIH Image files, but the raw data are automatically rescaled as maximum-contrast (0--255) 8-bit TIFF images -- even at 16-bit resolution -- which poses an inconvenience for quantitative analysis.) The 4pi plug-in module is designed for EDS X-ray mapping and allows simultaneous acquisition of maps from 48 elements plus an SEM image. The spectrum image was acquired by re-defining the energy intervals of 48 elements to form a series of contiguous 20 eV windows from 1.25 kV to 2.19 kV. A spectrum image of 450 x 344 pixels was acquired from the specimen with a sampling density of 50 nm/pixel and a dwell time of 0.25 live seconds per pixel, for a total acquisition time of {approximately}14 h. The binary data files were imported into Mathematica for analysis with software developed by the author at Oak Ridge National Laboratory. A 400 x 300 pixel section of the original image was analyzed. MSA required {approximately}185 Mbytes of memory and {approximately}18 h of CPU time on a 300 MHz Power Macintosh 9600.« less
ERIC Educational Resources Information Center
Dania, Jovinia; Bakar, Ab Rahim; Mohamed, Shamsiah
2014-01-01
The main purpose of the study was to assess the acquisition of employability skills by vocational students in Malaysia. A total of 214 students participated in the study. We used the SCANS instrument to assess vocational students' employability skills. The overall mean of vocational secondary students' employability skills was 3.81 (SD = 0.34).…
ERIC Educational Resources Information Center
Tekinarslan, Erkan
2013-01-01
The purpose of this study is to investigate the effects of screencasts on the Turkish undergraduate students' achievement and knowledge acquisitions in spreadsheet applications. The methodology of the study is based on a pretest-posttest experimental design with a control group. A total of 66 undergraduate students in two groups (n = 33 in…
ERIC Educational Resources Information Center
Bruno, Paula
This report assesses the Acquisition of Learning by Facilitating Academics (Project ALFA), which is designed to assist the academic progress of Haitian students at Lafayette High School in Brooklyn, New York. Project ALFA served a total of 62 students of limited English proficiency who had attended an English-speaking school system for less than 5…
1988-01-01
for this conference’s success goes to the panel chairmen and their panelists who gave generously of their time , effort, and talent, to the...Conference is the fourth in a series of bi-annual meetings convened to address timely issues affecting defense acquisition. Complementary goals are...the perspective on that issue has been clarified. o A lot of times we tend to look at acquisition, standardization, logistics, quality and other
Imaging industry expectations for compressed sensing in MRI
NASA Astrophysics Data System (ADS)
King, Kevin F.; Kanwischer, Adriana; Peters, Rob
2015-09-01
Compressed sensing requires compressible data, incoherent acquisition and a nonlinear reconstruction algorithm to force creation of a compressible image consistent with the acquired data. MRI images are compressible using various transforms (commonly total variation or wavelets). Incoherent acquisition of MRI data by appropriate selection of pseudo-random or non-Cartesian locations in k-space is straightforward. Increasingly, commercial scanners are sold with enough computing power to enable iterative reconstruction in reasonable times. Therefore integration of compressed sensing into commercial MRI products and clinical practice is beginning. MRI frequently requires the tradeoff of spatial resolution, temporal resolution and volume of spatial coverage to obtain reasonable scan times. Compressed sensing improves scan efficiency and reduces the need for this tradeoff. Benefits to the user will include shorter scans, greater patient comfort, better image quality, more contrast types per patient slot, the enabling of previously impractical applications, and higher throughput. Challenges to vendors include deciding which applications to prioritize, guaranteeing diagnostic image quality, maintaining acceptable usability and workflow, and acquisition and reconstruction algorithm details. Application choice depends on which customer needs the vendor wants to address. The changing healthcare environment is putting cost and productivity pressure on healthcare providers. The improved scan efficiency of compressed sensing can help alleviate some of this pressure. Image quality is strongly influenced by image compressibility and acceleration factor, which must be appropriately limited. Usability and workflow concerns include reconstruction time and user interface friendliness and response. Reconstruction times are limited to about one minute for acceptable workflow. The user interface should be designed to optimize workflow and minimize additional customer training. Algorithm concerns include the decision of which algorithms to implement as well as the problem of optimal setting of adjustable parameters. It will take imaging vendors several years to work through these challenges and provide solutions for a wide range of applications.
Fortin, Marc-Antoine; Landry, René
2016-05-02
This paper presents a universal GNSS receiver channel capable of tracking any civil GNSS signal. This fundamentally differs from dedicated channels, each customized for a given signal. A mobile device could integrate fewer universal channels to harvest all available signals. This would allow securing signal availability, while minimizing power consumption and chip size, thus maximizing battery lifetime. In fact, the universal channel allows sequential acquisition and tracking of any chipping rate, carrier frequency, FDMA channel, modulation, or constellation, and is totally configurable (any integration time, any discriminator, etc.). It can switch from one signal to another in 1.07 ms, making it possible for the receiver to rapidly adapt to its sensed environment. All this would consume 3.5 mW/channel in an ASIC implementation, i.e., with a slight overhead compared to the original GPS L1 C/A dedicated channel from which it was derived. After extensive surveys on GNSS signals and tracking channels, this paper details the implementation strategies that led to the proposed universal channel architecture. Validation is achieved using GNSS signals issued from different constellations, frequency bands, modulations and spreading code schemes. A discussion on acquisition approaches and conclusive remarks follow, which open up a new signal selection challenge, rather than satellite selection.
MASW on the standard seismic prospective scale using full spread recording
NASA Astrophysics Data System (ADS)
Białas, Sebastian; Majdański, Mariusz; Trzeciak, Maciej; Gałczyński, Edward; Maksym, Andrzej
2015-04-01
The Multichannel Analysis of Surface Waves (MASW) is one of seismic survey methods that use the dispersion curve of surface waves in order to describe the stiffness of the surface. Is is used mainly for geotechnical engineering scale with total length of spread between 5 - 450 m and spread offset between 1 - 100 m, the hummer is the seismic source on this surveys. The standard procedure of MASW survey is: data acquisition, dispersion analysis and inversion of extracting dispersion curve to obtain the closest theoretical curve. The final result includes share-wave velocity (Vs) values at different depth along the surveyed lines. The main goal of this work is to expand this engineering method to the bigger scale with the length of standard prospecting spread of 20 km using 4.5 Hz version of vertical component geophones. The standard vibroseis and explosive method are used as the seismic source. The acquisition were conducted on the full spread all the time during each single shoot. The seismic data acquisition used for this analysis were carried out on the Braniewo 2014 project in north of Poland. The results achieved during standard MASW procedure says that this method can be used on much bigger scale as well. The different methodology of this analysis requires only much stronger seismic source.
Fortin, Marc-Antoine; Landry, René
2016-01-01
This paper presents a universal GNSS receiver channel capable of tracking any civil GNSS signal. This fundamentally differs from dedicated channels, each customized for a given signal. A mobile device could integrate fewer universal channels to harvest all available signals. This would allow securing signal availability, while minimizing power consumption and chip size, thus maximizing battery lifetime. In fact, the universal channel allows sequential acquisition and tracking of any chipping rate, carrier frequency, FDMA channel, modulation, or constellation, and is totally configurable (any integration time, any discriminator, etc.). It can switch from one signal to another in 1.07 ms, making it possible for the receiver to rapidly adapt to its sensed environment. All this would consume 3.5 mW/channel in an ASIC implementation, i.e., with a slight overhead compared to the original GPS L1 C/A dedicated channel from which it was derived. After extensive surveys on GNSS signals and tracking channels, this paper details the implementation strategies that led to the proposed universal channel architecture. Validation is achieved using GNSS signals issued from different constellations, frequency bands, modulations and spreading code schemes. A discussion on acquisition approaches and conclusive remarks follow, which open up a new signal selection challenge, rather than satellite selection. PMID:27144569
48 CFR 19.502-2 - Total small business set-asides.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 1 2014-10-01 2014-10-01 false Total small business set... SOCIOECONOMIC PROGRAMS SMALL BUSINESS PROGRAMS Set-Asides for Small Business 19.502-2 Total small business set... exclusively for small business concerns and shall be set aside for small business unless the contracting...
48 CFR 19.502-2 - Total small business set-asides.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Total small business set... SOCIOECONOMIC PROGRAMS SMALL BUSINESS PROGRAMS Set-Asides for Small Business 19.502-2 Total small business set... contracting officer does not proceed with the small business set-aside and purchases on an unrestricted basis...
48 CFR 19.502-2 - Total small business set-asides.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Total small business set... SOCIOECONOMIC PROGRAMS SMALL BUSINESS PROGRAMS Set-Asides for Small Business 19.502-2 Total small business set... contracting officer does not proceed with the small business set-aside and purchases on an unrestricted basis...
48 CFR 19.502-2 - Total small business set-asides.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Total small business set... SOCIOECONOMIC PROGRAMS SMALL BUSINESS PROGRAMS Set-Asides for Small Business 19.502-2 Total small business set... contracting officer does not proceed with the small business set-aside and purchases on an unrestricted basis...
Proteomic analysis of formalin-fixed paraffin embedded tissue by MALDI imaging mass spectrometry
Casadonte, Rita; Caprioli, Richard M
2012-01-01
Archived formalin-fixed paraffin-embedded (FFPE) tissue collections represent a valuable informational resource for proteomic studies. Multiple FFPE core biopsies can be assembled in a single block to form tissue microarrays (TMAs). We describe a protocol for analyzing protein in FFPE -TMAs using matrix-assisted laser desorption/ionization (MAL DI) imaging mass spectrometry (IMS). The workflow incorporates an antigen retrieval step following deparaffinization, in situ trypsin digestion, matrix application and then mass spectrometry signal acquisition. The direct analysis of FFPE -TMA tissue using IMS allows direct analysis of multiple tissue samples in a single experiment without extraction and purification of proteins. The advantages of high speed and throughput, easy sample handling and excellent reproducibility make this technology a favorable approach for the proteomic analysis of clinical research cohorts with large sample numbers. For example, TMA analysis of 300 FFPE cores would typically require 6 h of total time through data acquisition, not including data analysis. PMID:22011652
Ringing Artefact Reduction By An Efficient Likelihood Improvement Method
NASA Astrophysics Data System (ADS)
Fuderer, Miha
1989-10-01
In MR imaging, the extent of the acquired spatial frequencies of the object is necessarily finite. The resulting image shows artefacts caused by "truncation" of its Fourier components. These are known as Gibbs artefacts or ringing artefacts. These artefacts are particularly. visible when the time-saving reduced acquisition method is used, say, when scanning only the lowest 70% of the 256 data lines. Filtering the data results in loss of resolution. A method is described that estimates the high frequency data from the low-frequency data lines, with the likelihood of the image as criterion. It is a computationally very efficient method, since it requires practically only two extra Fourier transforms, in addition to the normal. reconstruction. The results of this method on MR images of human subjects are promising. Evaluations on a 70% acquisition image show about 20% decrease of the error energy after processing. "Error energy" is defined as the total power of the difference to a 256-data-lines reference image. The elimination of ringing artefacts then appears almost complete..
Wireless biopotential acquisition system for portable healthcare monitoring.
Wang, W-S; Huang, H-Y; Wu, Z-C; Chen, S-C; Wang, W-F; Wu, C-F; Luo, C-H
2011-07-01
A complete biopotential acquisition system with an analogue front-end (AFE) chip is proposed for portable healthcare monitoring. A graphical user interface (GUI) is also implemented to display the extracted biopotential signals in real-time on a computer for patients or in a hospital via the internet for doctors. The AFE circuit defines the quality of the acquired biosignals. Thus, an AFE chip with low power consumption and a high common-mode rejection ratio (CMRR) was implemented in the TSMC 0.18-μm CMOS process. The measurement results show that the proposed AFE, with a core area of 0.1 mm(2), has a CMRR of 90 dB, and power consumption of 21.6 μW. Biopotential signals of electroencephalogram (EEG), electrocardiogram (ECG) and electromyogram (EMG) were measured to verify the proposed system. The board size of the proposed system is 6 cm × 2.5 cm and the weight is 30 g. The total power consumption of the proposed system is 66 mW. Copyright © 2011 Informa UK, Ltd.
Interlanguage Phonology: Acquisition of Timing Control in Japanese.
ERIC Educational Resources Information Center
Toda, Takako
1994-01-01
Studies the acquisition of timing control by Australians enrolled in first-year Japanese. Instrumental techniques are used to observe segment duration and pitch patterns in the speech production of learners and native speakers. Results indicate the learners can control timing, but their phonetic realization differs from that of native speakers.…
Measurement of gastric meal and secretion volumes using magnetic resonance imaging
Hoad, C.L.; Parker, H.; Hudders, N.; Costigan, C.; Cox, E.F.; Perkins, A.C.; Blackshaw, P.E.; Marciani, L.; Spiller, R.C.; Fox, M.R.; Gowland, P.A.
2015-01-01
MRI can assess multiple gastric functions without ionizing radiation. However, time consuming image acquisition and analysis of gastric volume data, plus confounding of gastric emptying measurements by gastric secretions mixed with the test meal have limited its use to research centres. This study presents an MRI acquisition protocol and analysis algorithm suitable for the clinical measurement of gastric volume and secretion volume. Reproducibility of gastric volume measurements was assessed using data from 10 healthy volunteers following a liquid test meal with rapid MRI acquisition within one breath-hold and semi-automated analysis. Dilution of the ingested meal with gastric secretion was estimated using a respiratory-triggered T1 mapping protocol. Accuracy of the secretion volume measurements was assessed using data from 24 healthy volunteers following a mixed (liquid/solid) test meal with MRI meal volumes compared to data acquired using gamma scintigraphy (GS) on the same subjects studied on a separate study day. The mean (SD) coefficient of variance between 3 observers for both total gastric contents (including meal, secretions and air) and just the gastric contents (meal and secretion only) was 3 (2) % at large gastric volumes (> 200 ml). Mean (SD) secretion volumes post meal ingestion were 64 (51) ml and 110 (40) ml at 15 and 75 minutes respectively. Comparison with GS meal volumes, showed that MRI meal only volume (after correction for secretion volume) were similar to GS, with a linear regression gradient (std err) of 1.06 (0.10) and intercept −11 (24) ml. In conclusion, (i) rapid acquisition removed the requirement to image during prolonged breath-hold (ii) semi-automatic analysis greatly reduced time required to derive measurements and (iii) correction for secretion volumes provides accurate assessment of gastric meal volumes and emptying. Together these features provide the scientific basis of a protocol which would be suitable in clinical practice. PMID:25592405
Kienesberger, Sabine; Perez-Perez, Guillermo I; Olivares, Asalia Z; Bardhan, Pradip; Sarker, Shafiqul A; Hasan, Kh Zahid; Sack, R Bradley; Blaser, Martin J
2018-03-01
Helicobacter pylori colonization is prevalent throughout the world, and is predominantly acquired during childhood. In developing countries, >70% of adult populations are colonized with H. pylori and >50% of children become colonized before the age of 10 years. However, the exact timing of acquisition is unknown. We assessed detection of H. pylori acquisition among a birth cohort of 105 children in Mirzapur, Bangladesh. Blood samples collected at time 0 (cord blood), and at 6, 12, 18, and 24 months of life were examined for the presence of IgG and IgA antibodies to whole cell H. pylori antigen and for IgG antibodies to the CagA antigen using specific ELISAs and immunoblotting. Breast milk samples were analyzed for H. pylori-specific IgA antibodies. Cord blood was used to establish maternal colonization status. H. pylori seroprevalence in the mothers was 92.8%. At the end of the two-year follow-up period, 50 (47.6%) of the 105 children were positive for H. pylori in more than one assay. Among the colonized children, CagA prevalence was 78.0%. A total of 58 children seroconverted: 50 children showed persistent colonization and 8 (7.6%) children showed transient seroconversion, but immunoblot analysis suggested that the transient seroconversion observed by ELISA may represent falsely positive results. Acquisition of H. pylori was not influenced by the mother H. pylori status in serum or breastmilk. In this population with high H. pylori prevalence, we confirmed that H. pylori in developing countries is detectable mainly after the first year of life.
[High Precision Identification of Igneous Rock Lithology by Laser Induced Breakdown Spectroscopy].
Wang, Chao; Zhang, Wei-gang; Yan, Zhi-quan
2015-09-01
In the field of petroleum exploration, lithology identification of finely cuttings sample, especially high precision identification of igneous rock with similar property, has become one of the geological problems. In order to solve this problem, a new method is proposed based on element analysis of Laser-Induced Breakdown Spectroscopy (LIBS) and Total Alkali versus Silica (TAS) diagram. Using independent LIBS system, factors influencing spectral signal, such as pulse energy, acquisition time delay, spectrum acquisition method and pre-ablation are researched through contrast experiments systematically. The best analysis conditions of igneous rock are determined: pulse energy is 50 mJ, acquisition time delay is 2 μs, the analysis result is integral average of 20 different points of sample's surface, and pre-ablation has been proved not suitable for igneous rock sample by experiment. The repeatability of spectral data is improved effectively. Characteristic lines of 7 elements (Na, Mg, Al, Si, K, Ca, Fe) commonly used for lithology identification of igneous rock are determined, and igneous rock samples of different lithology are analyzed and compared. Calibration curves of Na, K, Si are generated by using national standard series of rock samples, and all the linearly dependent coefficients are greater than 0.9. The accuracy of quantitative analysis is investigated by national standard samples. Element content of igneous rock is analyzed quantitatively by calibration curve, and its lithology is identified accurately by the method of TAS diagram, whose accuracy rate is 90.7%. The study indicates that LIBS can effectively achieve the high precision identification of the lithology of igneous rock.
Schizophrenia and second language acquisition.
Bersudsky, Yuly; Fine, Jonathan; Gorjaltsan, Igor; Chen, Osnat; Walters, Joel
2005-05-01
Language acquisition involves brain processes that can be affected by lesions or dysfunctions in several brain systems and second language acquisition may depend on different brain substrates than first language acquisition in childhood. A total of 16 Russian immigrants to Israel, 8 diagnosed schizophrenics and 8 healthy immigrants, were compared. The primary data for this study were collected via sociolinguistic interviews. The two groups use language and learn language in very much the same way. Only exophoric reference and blocking revealed meaningful differences between the schizophrenics and healthy counterparts. This does not mean of course that schizophrenia does not induce language abnormalities. Our study focuses on those aspects of language that are typically difficult to acquire in second language acquisition. Despite the cognitive compromises in schizophrenia and the manifest atypicalities in language of speakers with schizophrenia, the process of acquiring a second language seems relatively unaffected by schizophrenia.
Hara, Takanori; Urikura, Atsushi; Ichikawa, Katsuhiro; Hoshino, Takashi; Nishimaru, Eiji; Niwa, Shinji
2016-04-01
To analyse the temporal resolution (TR) of modern computed tomography (CT) scanners using the impulse method, and assess the actual maximum TR at respective helical acquisition modes. To assess the actual TR of helical acquisition modes of a 128-slice dual source CT (DSCT) scanner and a 320-row area detector CT (ADCT) scanner, we assessed the TRs of various acquisition combinations of a pitch factor (P) and gantry rotation time (R). The TR of the helical acquisition modes for the 128-slice DSCT scanner continuously improved with a shorter gantry rotation time and greater pitch factor. However, for the 320-row ADCT scanner, the TR with a pitch factor of <1.0 was almost equal to the gantry rotation time, whereas with pitch factor of >1.0, it was approximately one half of the gantry rotation time. The maximum TR values of single- and dual-source helical acquisition modes for the 128-slice DSCT scanner were 0.138 (R/P=0.285/1.5) and 0.074s (R/P=0.285/3.2), and the maximum TR values of the 64×0.5- and 160×0.5-mm detector configurations of the helical acquisition modes for the 320-row ADCT scanner were 0.120 (R/P=0.275/1.375) and 0.195s (R/P=0.3/0.6), respectively. Because the TR of a CT scanner is not accurately depicted in the specifications of the individual scanner, appropriate acquisition conditions should be determined based on the actual TR measurement. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Impact of Music in Reducing Patient Anxiety During Pediatric Ultrasound
Kesselman, Andrew; Bergen, Michael; Stefanov, Dimitre; Goldfisher, Rachelle; Amodio, John
2016-01-01
The use of noninvasive ultrasound examinations can potentially result in significant anxiety in the pediatric population. The purpose of this study was to assess the influence of music during pediatric ultrasound examinations to reduce anxiety measured by heart rate. A total of 44 patients were recruited; 21 controls and 23 experimental. Each participant was randomized to either music or no music (control) after parental consent was obtained. Pulse oximeters were used to monitor heart rate at 15 second intervals for a total of 1 minute, with mean values calculated prior to entering the procedure room, during the middle of the procedure, and after the procedure was completed. The total scan time was determined from the initial image acquisition until the last image recorded by the ultrasound technologist. At the completion of each procedure, the ultrasound technologist scored the ease of performance for the scan on a subjective scale of 1-10 based on prior experience. When utilizing music during pediatric ultrasounds examinations, our study demonstrated significantly decreased heart rate variability from pre-procedural to post-procedural periods. There was no statistical significant difference in total scan time or ultrasound technologist scoring between the two groups. This study demonstrates that music is an inexpensive and effective means of reducing anxiety during pediatric ultrasound as indicated by heart rate. PMID:27114817
Performance evaluation of a high resolution dedicated breast PET scanner
DOE Office of Scientific and Technical Information (OSTI.GOV)
García Hernández, Trinitat, E-mail: mtrinitat@eresa.com; Vicedo González, Aurora; Brualla González, Luis
2016-05-15
Purpose: Early stage breast cancers may not be visible on a whole-body PET scan. To overcome whole-body PET limitations, several dedicated breast positron emission tomography (DbPET) systems have emerged nowadays aiming to improve spatial resolution. In this work the authors evaluate the performance of a high resolution dedicated breast PET scanner (Mammi-PET, Oncovision). Methods: Global status, uniformity, sensitivity, energy, and spatial resolution were measured. Spheres of different sizes (2.5, 4, 5, and 6 mm diameter) and various 18 fluorodeoxyglucose ({sup 18}F-FDG) activity concentrations were randomly inserted in a gelatine breast phantom developed at our institution. Several lesion-to-background ratios (LBR) weremore » simulated, 5:1, 10:1, 20:1, 30:1, and 50:1. Images were reconstructed using different voxel sizes. The ability of experienced reporters to detect spheres was tested as a function of acquisition time, LBR, sphere size, and matrix reconstruction voxel size. For comparison, phantoms were scanned in the DbPET camera and in a whole body PET (WB-PET). Two patients who just underwent WB-PET/CT exams were imaged with the DbPET system and the images were compared. Results: The measured absolute peak sensitivity was 2.0%. The energy resolution was 24.0% ± 1%. The integral and differential uniformity were 10% and 6% in the total field of view (FOV) and 9% and 5% in the central FOV, respectively. The measured spatial resolution was 2.0, 1.9, and 1.7 mm in the radial, tangential, and axial directions. The system exhibited very good detectability for spheres ≥4 mm and LBR ≥10 with a sphere detection of 100% when acquisition time was set >3 min/bed. For LBR = 5 and acquisition time of 7 min the detectability was 100% for spheres of 6 mm and 75% for spheres of 5, 4, and 2.5 mm. Lesion WB-PET detectability was only comparable to the DbPET camera for lesion sizes ≥5 mm when acquisition time was >3 min and LBR > 10. Conclusions: The DbPET has a good performance for its clinical use and shows an improved resolution and lesion detectability of small lesions compared to WB-PET.« less
Phase imaging in brain using SWIFT
NASA Astrophysics Data System (ADS)
Lehto, Lauri Juhani; Garwood, Michael; Gröhn, Olli; Corum, Curtis Andrew
2015-03-01
The majority of MRI phase imaging is based on gradient recalled echo (GRE) sequences. This work studies phase contrast behavior due to small off-resonance frequency offsets in brain using SWIFT, a FID-based sequence with nearly zero acquisition delay. 1D simulations and a phantom study were conducted to describe the behavior of phase accumulation in SWIFT. Imaging experiments of known brain phase contrast properties were conducted in a perfused rat brain comparing GRE and SWIFT. Additionally, a human brain sample was imaged. It is demonstrated how SWIFT phase is orientation dependent and correlates well with GRE, linking SWIFT phase to similar off-resonance sources as GRE. The acquisition time is shown to be analogous to TE for phase accumulation time. Using experiments with and without a magnetization transfer preparation, the likely effect of myelin water pool contribution is seen as a phase increase for all acquisition times. Due to the phase accumulation during acquisition, SWIFT phase contrast can be sensitized to small frequency differences between white and gray matter using low acquisition bandwidths.
NASA Technical Reports Server (NTRS)
Reiber, J. H. C.
1976-01-01
To automate the data acquisition procedure, a real-time contour detection and data acquisition system for the left ventricular outline was developed using video techniques. The X-ray image of the contrast-filled left ventricle is stored for subsequent processing on film (cineangiogram), video tape or disc. The cineangiogram is converted into video format using a television camera. The video signal from either the TV camera, video tape or disc is the input signal to the system. The contour detection is based on a dynamic thresholding technique. Since the left ventricular outline is a smooth continuous function, for each contour side a narrow expectation window is defined in which the next borderpoint will be detected. A computer interface was designed and built for the online acquisition of the coordinates using a PDP-12 computer. The advantage of this system over other available systems is its potential for online, real-time acquisition of the left ventricular size and shape during angiocardiography.
Laohavaleeson, Somvadee; Barriere, Steven L; Nicolau, David P; Kuti, Joseph L
2008-12-01
To determine the cost-effectiveness of telavancin versus vancomycin for the treatment of complicated skin and skin structure infections (cSSSIs). Pharmacoeconomic analysis conducted from the hospital's perspective using data from the Assessment of Telavancin in Complicated Skin and Skin Structure Infections (ATLAS) phase III clinical trial. One hundred twenty-nine hospitals in the United States and internationally. A total of 1044 clinically evaluable patients who were hospitalized with a cSSSI during the ATLAS trial and who received at least one dose of telavancin or vancomycin in the hospital. Diagnosis-related group-specific hospital bed costs, antibiotic acquisition prices, and cost of vancomycin monitoring were applied to the resource utilization data collected during the ATLAS trial. Infection-related length of stay (LOS(ir)) and hospitalization costs (COST(ir)) were compared between the telavancin (514 patients) and vancomycin (530 patients) groups. Incremental cost-effectiveness ratios (ICERs) were calculated for the total population and a subset of patients infected with methicillin-resistant Staphylococcus aureus (MRSA) by using a 25,000-sample bootstrap analysis. During sensitivity analyses, the daily acquisition price for telavancin was increased from the equivalent to vancomycin ($13.44) to $50, $100, $150, or $200, and the rate of MRSA acquisition was varied between 30% and 75%. The median (interquartile range) LOS(ir) was 8 days (6-12 days) for both telavancin and vancomycin (p=0.742), and median (interquartile range) COST(ir) was $8118 ($6291-11,758) and $8185 ($6474-11,405), respectively (p=0.560). Similar findings were observed for the MRSA subset. Telavancin cost-effectiveness was greater for the MRSA population versus the total population. During bootstrap analyses of the MRSA population, the ICER for telavancin ranged from dominant (-$9560) to $27,889 as acquisition price was increased. Telavancin LOS(ir) and total COST(ir) were similar to those of vancomycin for the treatment of cSSSIs. Particularly in those infected with MRSA, telavancin may be more cost-effective than vancomycin over the range of acquisition prices tested.
A seamless acquisition digital storage oscilloscope with three-dimensional waveform display
NASA Astrophysics Data System (ADS)
Yang, Kuojun; Tian, Shulin; Zeng, Hao; Qiu, Lei; Guo, Lianping
2014-04-01
In traditional digital storage oscilloscope (DSO), sampled data need to be processed after each acquisition. During data processing, the acquisition is stopped and oscilloscope is blind to the input signal. Thus, this duration is called dead time. With the rapid development of modern electronic systems, the effect of infrequent events becomes significant. To capture these occasional events in shorter time, dead time in traditional DSO that causes the loss of measured signal needs to be reduced or even eliminated. In this paper, a seamless acquisition oscilloscope without dead time is proposed. In this oscilloscope, three-dimensional waveform mapping (TWM) technique, which converts sampled data to displayed waveform, is proposed. With this technique, not only the process speed is improved, but also the probability information of waveform is displayed with different brightness. Thus, a three-dimensional waveform is shown to the user. To reduce processing time further, parallel TWM which processes several sampled points simultaneously, and dual-port random access memory based pipelining technique which can process one sampling point in one clock period are proposed. Furthermore, two DDR3 (Double-Data-Rate Three Synchronous Dynamic Random Access Memory) are used for storing sampled data alternately, thus the acquisition can continue during data processing. Therefore, the dead time of DSO is eliminated. In addition, a double-pulse test method is adopted to test the waveform capturing rate (WCR) of the oscilloscope and a combined pulse test method is employed to evaluate the oscilloscope's capture ability comprehensively. The experiment results show that the WCR of the designed oscilloscope is 6 250 000 wfms/s (waveforms per second), the highest value in all existing oscilloscopes. The testing results also prove that there is no dead time in our oscilloscope, thus realizing the seamless acquisition.
A seamless acquisition digital storage oscilloscope with three-dimensional waveform display
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Kuojun, E-mail: kuojunyang@gmail.com; Guo, Lianping; School of Electrical and Electronic Engineering, Nanyang Technological University
In traditional digital storage oscilloscope (DSO), sampled data need to be processed after each acquisition. During data processing, the acquisition is stopped and oscilloscope is blind to the input signal. Thus, this duration is called dead time. With the rapid development of modern electronic systems, the effect of infrequent events becomes significant. To capture these occasional events in shorter time, dead time in traditional DSO that causes the loss of measured signal needs to be reduced or even eliminated. In this paper, a seamless acquisition oscilloscope without dead time is proposed. In this oscilloscope, three-dimensional waveform mapping (TWM) technique, whichmore » converts sampled data to displayed waveform, is proposed. With this technique, not only the process speed is improved, but also the probability information of waveform is displayed with different brightness. Thus, a three-dimensional waveform is shown to the user. To reduce processing time further, parallel TWM which processes several sampled points simultaneously, and dual-port random access memory based pipelining technique which can process one sampling point in one clock period are proposed. Furthermore, two DDR3 (Double-Data-Rate Three Synchronous Dynamic Random Access Memory) are used for storing sampled data alternately, thus the acquisition can continue during data processing. Therefore, the dead time of DSO is eliminated. In addition, a double-pulse test method is adopted to test the waveform capturing rate (WCR) of the oscilloscope and a combined pulse test method is employed to evaluate the oscilloscope's capture ability comprehensively. The experiment results show that the WCR of the designed oscilloscope is 6 250 000 wfms/s (waveforms per second), the highest value in all existing oscilloscopes. The testing results also prove that there is no dead time in our oscilloscope, thus realizing the seamless acquisition.« less
NASA Astrophysics Data System (ADS)
Dong, Kyung-Rae; Shim, Dong-Oh; Kim, Ho-Sung; Park, Yong-Soon; Chung, Woon-Kwan; Cho, Jae-Hwan
2013-02-01
In a nuclear medicine examination, methods to acquire a static image include the preset count method and the preset time method. The preset count method is used mainly in a static renal scan that utilizes 99 m Tc-DMSA (dimoercaptosuccinic acid) whereas the preset time method is used occasionally. When the preset count method is used, the same number of acquisition counts is acquired for each time, but the scan time varies. When the preset time method is used, the scan time is constant, but the number of counts acquired is not the same. Therefore, this study examined the dependence of the difference in information on the function and the shape of both sides of the kidneys on the counts acquired during a renal scan that utilizes 99 m Tc-DMSA. The study involved patients who had 40-60% relative function of one kidney among patients who underwent a 99 m Tc-DMSA renal scan in the Nuclear Medicine Department during the period from January 11 to March 31, 2012. A gamma camera was used to obtain the acquisition count continuously using 100,000 counts and 300,000 counts, and an acquisition time of 7 minutes (exceeding 300,000 counts). The function and the shape of the kidney were evaluated by measuring the relative function of both sides of the kidneys, the geometric mean, and the size of kidney before comparative analysis. According to the study results, neither the relative function nor the geometric mean of both sides of the kidneys varied significantly with the acquisition count. On the other hand, the size of the kidney tended to be larger with increasing acquisition count.
Indoor integrated navigation and synchronous data acquisition method for Android smartphone
NASA Astrophysics Data System (ADS)
Hu, Chunsheng; Wei, Wenjian; Qin, Shiqiao; Wang, Xingshu; Habib, Ayman; Wang, Ruisheng
2015-08-01
Smartphones are widely used at present. Most smartphones have cameras and kinds of sensors, such as gyroscope, accelerometer and magnet meter. Indoor navigation based on smartphone is very important and valuable. According to the features of the smartphone and indoor navigation, a new indoor integrated navigation method is proposed, which uses MEMS (Micro-Electro-Mechanical Systems) IMU (Inertial Measurement Unit), camera and magnet meter of smartphone. The proposed navigation method mainly involves data acquisition, camera calibration, image measurement, IMU calibration, initial alignment, strapdown integral, zero velocity update and integrated navigation. Synchronous data acquisition of the sensors (gyroscope, accelerometer and magnet meter) and the camera is the base of the indoor navigation on the smartphone. A camera data acquisition method is introduced, which uses the camera class of Android to record images and time of smartphone camera. Two kinds of sensor data acquisition methods are introduced and compared. The first method records sensor data and time with the SensorManager of Android. The second method realizes open, close, data receiving and saving functions in C language, and calls the sensor functions in Java language with JNI interface. A data acquisition software is developed with JDK (Java Development Kit), Android ADT (Android Development Tools) and NDK (Native Development Kit). The software can record camera data, sensor data and time at the same time. Data acquisition experiments have been done with the developed software and Sumsang Note 2 smartphone. The experimental results show that the first method of sensor data acquisition is convenient but lost the sensor data sometimes, the second method is much better in real-time performance and much less in data losing. A checkerboard image is recorded, and the corner points of the checkerboard are detected with the Harris method. The sensor data of gyroscope, accelerometer and magnet meter have been recorded about 30 minutes. The bias stability and noise feature of the sensors have been analyzed. Besides the indoor integrated navigation, the integrated navigation and synchronous data acquisition method can be applied to outdoor navigation.
The Block V Receiver fast acquisition algorithm for the Galileo S-band mission
NASA Technical Reports Server (NTRS)
Aung, M.; Hurd, W. J.; Buu, C. M.; Berner, J. B.; Stephens, S. A.; Gevargiz, J. M.
1994-01-01
A fast acquisition algorithm for the Galileo suppressed carrier, subcarrier, and data symbol signals under low data rate, signal-to-noise ratio (SNR) and high carrier phase-noise conditions has been developed. The algorithm employs a two-arm fast Fourier transform (FFT) method utilizing both the in-phase and quadrature-phase channels of the carrier. The use of both channels results in an improved SNR in the FFT acquisition, enabling the use of a shorter FFT period over which the carrier instability is expected to be less significant. The use of a two-arm FFT also enables subcarrier and symbol acquisition before carrier acquisition. With the subcarrier and symbol loops locked first, the carrier can be acquired from an even shorter FFT period. Two-arm tracking loops are employed to lock the subcarrier and symbol loops parameter modification to achieve the final (high) loop SNR in the shortest time possible. The fast acquisition algorithm is implemented in the Block V Receiver (BVR). This article describes the complete algorithm design, the extensive computer simulation work done for verification of the design and the analysis, implementation issues in the BVR, and the acquisition times of the algorithm. In the expected case of the Galileo spacecraft at Jupiter orbit insertion PD/No equals 14.6 dB-Hz, R(sym) equals 16 symbols per sec, and the predicted acquisition time of the algorithm (to attain a 0.2-dB degradation from each loop to the output symbol SNR) is 38 sec.
Fu, Riqiang; Hernández-Maldonado, Arturo J
2018-05-24
A small flip-angle pulse direct polarization is the simplest method commonly used to quantify various compositions in many materials applications. This method sacrifices the sensitivity per scan in exchange for rapid repeating of data acquisition for signal accumulation. In addition, the resulting spectrum often encounters artifacts from background signals from probe components and/or from acoustic rings leading to a distorted baseline, especially in low-γ nuclei and wideline NMR. In this work, a multi-acquisition scheme is proposed to boost the sensitivity per scan and at the same time effectively suppress these artifacts. Here, an adiabatic inversion pulse is first applied in order to bring the magnetization from the +z to -z axis and then a small flip-angle pulse excitation is used before the data acquisition. Right after the first acquisition, the adiabatic inversion pulse is applied again to flip the magnetization back to the +z axis. The second data acquisition takes place after another small flip-angle pulse excitation. The difference between the two consecutive acquisitions cancels out any artifacts, while the wanted signals are accumulated. This acquisition process can be repeated many times before going into next scan. Therefore, by acquiring the signals multiple times in a single scan the sensitivity is improved. A mixture sample of flufenamic acid and 3,5-difluorobenzoic acid and a titanium silicate sample have been used to demonstrate the advantages of this newly proposed method. Copyright © 2018 Elsevier Inc. All rights reserved.
Zhao, Hongbo; Chen, Yuying; Feng, Wenquan; Zhuang, Chen
2018-05-25
Inter-satellite links are an important component of the new generation of satellite navigation systems, characterized by low signal-to-noise ratio (SNR), complex electromagnetic interference and the short time slot of each satellite, which brings difficulties to the acquisition stage. The inter-satellite link in both Global Positioning System (GPS) and BeiDou Navigation Satellite System (BDS) adopt the long code spread spectrum system. However, long code acquisition is a difficult and time-consuming task due to the long code period. Traditional folding methods such as extended replica folding acquisition search technique (XFAST) and direct average are largely restricted because of code Doppler and additional SNR loss caused by replica folding. The dual folding method (DF-XFAST) and dual-channel method have been proposed to achieve long code acquisition in low SNR and high dynamic situations, respectively, but the former is easily affected by code Doppler and the latter is not fast enough. Considering the environment of inter-satellite links and the problems of existing algorithms, this paper proposes a new long code acquisition algorithm named dual-channel acquisition method based on the extended replica folding algorithm (DC-XFAST). This method employs dual channels for verification. Each channel contains an incoming signal block. Local code samples are folded and zero-padded to the length of the incoming signal block. After a circular FFT operation, the correlation results contain two peaks of the same magnitude and specified relative position. The detection process is eased through finding the two largest values. The verification takes all the full and partial peaks into account. Numerical results reveal that the DC-XFAST method can improve acquisition performance while acquisition speed is guaranteed. The method has a significantly higher acquisition probability than folding methods XFAST and DF-XFAST. Moreover, with the advantage of higher detection probability and lower false alarm probability, it has a lower mean acquisition time than traditional XFAST, DF-XFAST and zero-padding.
Acquisition of speech rhythm in first language.
Polyanskaya, Leona; Ordin, Mikhail
2015-09-01
Analysis of English rhythm in speech produced by children and adults revealed that speech rhythm becomes increasingly more stress-timed as language acquisition progresses. Children reach the adult-like target by 11 to 12 years. The employed speech elicitation paradigm ensured that the sentences produced by adults and children at different ages were comparable in terms of lexical content, segmental composition, and phonotactic complexity. Detected differences between child and adult rhythm and between rhythm in child speech at various ages cannot be attributed to acquisition of phonotactic language features or vocabulary, and indicate the development of language-specific phonetic timing in the course of acquisition.
Accelerating acquisition strategies for low-frequency conductivity imaging using MREIT
NASA Astrophysics Data System (ADS)
Song, Yizhuang; Seo, Jin Keun; Chauhan, Munish; Indahlastari, Aprinda; Ashok Kumar, Neeta; Sadleir, Rosalind
2018-02-01
We sought to improve efficiency of magnetic resonance electrical impedance tomography data acquisition so that fast conductivity changes or electric field variations could be monitored. Undersampling of k-space was used to decrease acquisition times in spin-echo-based sequences by a factor of two. Full MREIT data were reconstructed using continuity assumptions and preliminary scans gathered without current. We found that phase data were reconstructed faithfully from undersampled data. Conductivity reconstructions of phantom data were also possible. Therefore, undersampled k-space methods can potentially be used to accelerate MREIT acquisition. This method could be an advantage in imaging real-time conductivity changes with MREIT.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-26
... Federal Acquisition Regulation; Changes to Time-and-Materials and Labor-Hour Contracts and Orders AGENCIES... changing the scope of work for a time-and-materials (T&M) or labor-hour (LH) contract or order. DATES...-043, ``Time-and-Materials and Labor-Hour Contracts for Commercial Items'', was published as a final...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-28
..., Sequence 1] RIN 9000-AM28 Federal Acquisition Regulation; Changes to Time-and-Materials and Labor-Hour... raising the ceiling price or otherwise changing the scope of work for a time-and-materials (T&M) or labor... summarized as follows: In finalizing FAR rule 2009-043 Time-and-Materials and Labor- Hour Contracts for...
One dimensional two-body collisions experiment based on LabVIEW interface with Arduino
NASA Astrophysics Data System (ADS)
Saphet, Parinya; Tong-on, Anusorn; Thepnurat, Meechai
2017-09-01
The purpose of this work is to build a physics lab apparatus that is modern, low-cost and simple. In one dimensional two-body collisions experiment, we used the Arduino UNO R3 as a data acquisition system which was controlled by LabVIEW program. The photogate sensors were designed using LED and LDR to measure position as a function of the time. Aluminium frame houseware and blower were used for the air track system. In both totally inelastic and elastic collision experiments, the results of momentum and energy conservation are in good agreement with the theoretical calculations.
Performance of the Defense Acquisition System, 2013 Annual Report
2013-06-28
well beyond their start dates, which could indicate factors not attributable to the initial management of the contracts. Figure 2-13. DoD Total ...Attributed to W. Edwards Deming While the United States achieves its national security missions by equipping its military forces with the best weapons...annual reports on the performance of the defense acquisition system—its programs, institutions, workforce, managers , executives, and industrial partners
Feasibility Study for an Autonomous UAV - Magnetometer System
2007-11-01
collect data from multiple magnetometers at high sampling rates (~100 Hz), and associated with these acquisition systems are highly accurate...component for an UAV helicopter- magnetometer system is the ability to have precise positioning (both for flightpath execution and for data acquisition...discussed under section 6.3. Figure 6.11 shows the fluxgate data used to compensate a total field magnetometer as previously described. The red
Internal Controls Over the Army Military Equipment Baseline Valuation Effort
2008-08-29
Equipment and required thai military equipment assets be capitalized and depreciated . The Under Secretary of Defense (Acquisition, Technology, and...Property, Plant, and Equipment and requires that military equipment assets be capitalized and depreciated . Prior to SFFAS No. 23, DoD expensed military...net book value of military equipment is the total acquisition cost minus the accumulated depreciation . The Army’s financial statements also include
Anadarko's Proposed Acquisition of Kerr-McGee and Western Gas Resources
2006-01-01
Presentation of company-level, non-proprietary data and relevant aggregate data for worldwide oil and natural gas reserves and production of Anadarko, Kerr-McGee, and Western Gas Resources to inform discussions of Anadarko Petroleum Corp.'s proposed acquisition of both Kerr-McGee Corp. and Western Gas Resources Inc. for a total of $23.3 billion, which was announced June 23, 2006.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-26
...) Payments of this clause, but the ``hourly rate'' for labor hours expended in furnishing work not delivered...] RIN 9000-AM01 Federal Acquisition Regulation; Payments Under Time-and-Materials and Labor-Hour... the authorization to use time-and-materials and labor-hour contract payment requirements. DATES...
Eydipour, Zainab; Vaezi, Gholamhassan; Nasehi, Mohammad; Haeri-Rouhani, Seyed-Ali; Zarrindast, Mohammad-Reza
2017-09-01
Serotonin receptors such as 5-HT3 plays critical role in regulation of sleep, wake cycle and cognitive process. Thus, we investigated the role of CA1 5HT3 serotonin receptors in memory acquisition deficit induced by total sleep deprivation (TSD; for 24 hour) and REM sleep deprivation (RSD; for 24 hour). Pain perception and locomotor activity were also assessed as factors that may affect the memory process. Modified water box and multi-platform apparatus were used to induce TSD or RSD, respectively. Passive avoidance, hot plate and open field devices were used for assessment of memory acquisition, pain and locomotor activity, respectively. Totally, 152 male Wistar rats were used in the study. Pre-training, intra-CA1 injection of 5-HT3 receptor agonist Chlorophenylbiguanide (Mchl; 0.01 and 0.001 µg/rat; P < 0.001) and antagonist Y-25130 (0.1 µg/rat; P < 0.001) reduced memory acquisition and did not alter pain response, while higher dose of both drugs increased locomotor activity in normal rats. Both TSD and RSD reduced memory acquisition (P < 0.001) and did not alter locomotor activity, while TSD (P < 0.001) but not RSD induced analgesia effect. The amnesia induced by TSD was restored by subthreshold dose of Y25130 (0.001 µg/rat; P < 0.001) but not Mchl (0.0001 µg/rat), while both drugs reversed TSD-induced analgesia effect (P < 0.01 for Mchl and P < 0.05 for Y25130), and Y25130 increased locomotor activity in TSD rats (P < 0.05). In RSD rats, subthreshold dose of both drugs did not alter memory acquisition deficit and increased locomotor activity (P < 0.001 for Mchl and P < 0.01 for Y25130), while the Y25130 (P < 0.001), but not Mchl induced analgesia in the RSD rats. Based on the above data, CA1 5HT3 receptors seem to play a critical role in cognitive and non-cognitive behaviors induced by TSD and RSD.
Jin, Peng; van Wieringen, Niek; Hulshof, Maarten C C M; Bel, Arjan; Alderliesten, Tanja
2018-04-01
Use of four-dimensional cone-beam CT (4D-CBCT) and fiducial markers for image guidance during radiation therapy (RT) of mobile tumors is challenging due to the trade-off among image quality, imaging dose, and scanning time. This study aimed to investigate different 4D-CBCT acquisition settings for good visibility of fiducial markers in 4D-CBCT. Using these 4D-CBCTs, the feasibility of marker-based 4D registration for RT setup verification and manual respiration-induced motion quantification was investigated. For this, we applied a dynamic phantom with three different breathing motion amplitudes and included two patients with implanted markers. Irrespective of the motion amplitude, for a medium field of view (FOV), marker visibility was improved by reducing the imaging dose per projection and increasing the number of projection images; however, the scanning time was 4 to 8 min. For a small FOV, the total imaging dose and the scanning time were reduced (62.5% of the dose using a medium FOV, 2.5 min) without losing marker visibility. However, the body contour could be missing for a small FOV, which is not preferred in RT. The marker-based 4D setup verification was feasible for both the phantom and patient data. Moreover, manual marker motion quantification can achieve a high accuracy with a mean error of [Formula: see text].
Importance of nondrug costs of intravenous antibiotic therapy.
van Zanten, Arthur R H; Engelfriet, Peter M; van Dillen, Karin; van Veen, Miriam; Nuijten, Mark J C; Polderman, Kees H
2003-12-01
Costs are one of the factors determining physicians' choice of medication to treat patients in specific situations. However, usually only the drug acquisition costs are taken into account, whereas other factors such as the use of disposable materials, the drug preparation time and the staff workload are insufficiently taken into consideration. We therefore decided to assess true overall costs of intravenous (IV) antibiotic administration by performing an activity-based costing approach. A prospective survey on costs and workload by means of a time and motion analysis and activity-based costing was performed in a 605-bed secondary referral centre with 20 intensive care unit beds. The subjects were 50 consecutive patients admitted to our hospital with community-acquired pneumonia or intra-abdominal infections requiring treatment with IV antibiotics. A time and motion analysis of 103 routine acts of preparing and administering IV antibiotics was performed in the intensive care unit and in the Department of Internal Medicine. To measure the entire process an inventory and work flowchart were made using detailed questionnaires completed by members of the nursing staff, the medical staff and the pharmacy staff. In addition, questionnaires were distributed to management and secretarial staff to determine additional overhead costs. The average costs for different methods of IV antibiotic administration were then compared by timing all steps in the process. Four different methods of drug administration were used: administration by volumetric pump, administration by syringe pump, administration by 'unaided' infusion bag, and administration by direct IV injection. The average times required for each of these procedures, including preparation and administration of the drug, were 4:49 +/- 2:37, 4:56 +/- 2:03, 5:51 +/- 3:33 and 9:21 +/- 2:16 min (mean minutes:seconds +/- standard deviation), respectively. When the costs for expended staff time and materials (not including drug costs) were calculated this resulted in average costs of 5.65, 7.28, 5.36 and 3.83, respectively, for administration of each dose of antibiotics. These costs represent between 11% and 53% of the total daily costs of antibiotic therapy. Compared with the acquisition costs, these indirect costs ranged from 13% to 113%. Not included in this comparison is the time required for insertion of an IV catheter, which was found to be 10:15 +/- 6:31 min with an average calculated cost of 9.17. Total costs of IV antibiotic administration are formed not only by the costs of the drugs themselves, but also, to a substantial degree, by the time expended by medical and nursing staff, costs of disposable materials and overhead costs. Physicians making decisions regarding the use of specific medications in intensive care unit patients should take these factors into account. Use of IV antibiotics is associated with considerable workload and additional costs that can exceed the acquisition costs of the medications themselves.
Acoustic noise reduction in T 1- and proton-density-weighted turbo spin-echo imaging.
Ott, Martin; Blaimer, Martin; Breuer, Felix; Grodzki, David; Heismann, Björn; Jakob, Peter
2016-02-01
To reduce acoustic noise levels in T 1-weighted and proton-density-weighted turbo spin-echo (TSE) sequences, which typically reach acoustic noise levels up to 100 dB(A) in clinical practice. Five acoustic noise reduction strategies were combined: (1) gradient ramps and shapes were changed from trapezoidal to triangular, (2) variable-encoding-time imaging was implemented to relax the phase-encoding gradient timing, (3) RF pulses were adapted to avoid the need for reversing the polarity of the slice-rewinding gradient, (4) readout bandwidth was increased to provide more time for gradient activity on other axes, (5) the number of slices per TR was reduced to limit the total gradient activity per unit time. We evaluated the influence of each measure on the acoustic noise level, and conducted in vivo measurements on a healthy volunteer. Sound recordings were taken for comparison. An overall acoustic noise reduction of up to 16.8 dB(A) was obtained by the proposed strategies (1-4) and the acquisition of half the number of slices per TR only. Image quality in terms of SNR and CNR was found to be preserved. The proposed measures in this study allowed a threefold reduction in the acoustic perception of T 1-weighted and proton-density-weighted TSE sequences compared to a standard TSE-acquisition. This could be achieved without visible degradation of image quality, showing the potential to improve patient comfort and scan acceptability.
48 CFR 5108.070 - Definitions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... capacity for a negotiated length of time, to conduct subcontractor planning, and to produce specified... capacity for a negotiated length of time, to conduct subcontractor planning, and to produce specified... Section 5108.070 Federal Acquisition Regulations System DEPARTMENT OF THE ARMY ACQUISITION REGULATIONS...
Mason, H. E.; Uribe, E. C.; Shusterman, J. A.
2018-01-01
Tensor-rank decomposition methods have been applied to variable contact time 29 Si{ 1 H} CP/CPMG NMR data sets to extract NMR dynamics information and dramatically decrease conventional NMR acquisition times.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mason, H. E.; Uribe, E. C.; Shusterman, J. A.
Tensor-rank decomposition methods have been applied to variable contact time 29 Si{ 1 H} CP/CPMG NMR data sets to extract NMR dynamics information and dramatically decrease conventional NMR acquisition times.
Use of a priori statistics to minimize acquisition time for RFI immune spread spectrum systems
NASA Technical Reports Server (NTRS)
Holmes, J. K.; Woo, K. T.
1978-01-01
The optimum acquisition sweep strategy was determined for a PN code despreader when the a priori probability density function was not uniform. A psuedo noise spread spectrum system was considered which could be utilized in the DSN to combat radio frequency interference. In a sample case, when the a priori probability density function was Gaussian, the acquisition time was reduced by about 41% compared to a uniform sweep approach.
NASA Astrophysics Data System (ADS)
Krauze, W.; Makowski, P.; Kujawińska, M.
2015-06-01
Standard tomographic algorithms applied to optical limited-angle tomography result in the reconstructions that have highly anisotropic resolution and thus special algorithms are developed. State of the art approaches utilize the Total Variation (TV) minimization technique. These methods give very good results but are applicable to piecewise constant structures only. In this paper, we propose a novel algorithm for 3D limited-angle tomography - Total Variation Iterative Constraint method (TVIC) which enhances the applicability of the TV regularization to non-piecewise constant samples, like biological cells. This approach consists of two parts. First, the TV minimization is used as a strong regularizer to create a sharp-edged image converted to a 3D binary mask which is then iteratively applied in the tomographic reconstruction as a constraint in the object domain. In the present work we test the method on a synthetic object designed to mimic basic structures of a living cell. For simplicity, the test reconstructions were performed within the straight-line propagation model (SIRT3D solver from the ASTRA Tomography Toolbox), but the strategy is general enough to supplement any algorithm for tomographic reconstruction that supports arbitrary geometries of plane-wave projection acquisition. This includes optical diffraction tomography solvers. The obtained reconstructions present resolution uniformity and general shape accuracy expected from the TV regularization based solvers, but keeping the smooth internal structures of the object at the same time. Comparison between three different patterns of object illumination arrangement show very small impact of the projection acquisition geometry on the image quality.
The total cost of EHR ownership.
Eastaugh, Steven R
2013-02-01
Consider total cost of ownership, not just initial cost of acquisition and annual maintenance, when reviewing electronic health record (EHR) system bids. Support costs--a key part of total cost of ownership--include FTEs dedicated to the system. The long-term costs of an EHR system can vary dramatically (up to 200 percent) depending on which system is selected.
Recent Advances in 3D Time-Resolved Contrast-Enhanced MR Angiography
Riederer, Stephen J.; Haider, Clifton R.; Borisch, Eric A.; Weavers, Paul T.; Young, Phillip M.
2015-01-01
Contrast-enhanced MR angiography (CE-MRA) was first introduced for clinical studies approximately 20 years ago. Early work provided 3 to 4 mm spatial resolution with acquisition times in the 30 sec range. Since that time there has been continuing effort to provide improved spatial resolution with reduced acquisition time, allowing high resolution three-dimensional (3D) time-resolved studies. The purpose of this work is to describe how this has been accomplished. Specific technical enablers have been: improved gradients allowing reduced repetition times, improved k-space sampling and reconstruction methods, parallel acquisition particularly in two directions, and improved and higher count receiver coil arrays. These have collectively made high resolution time-resolved studies readily available for many anatomic regions. Depending on the application, approximate 1 mm isotropic resolution is now possible with frame times of several seconds. Clinical applications of time-resolved CE-MRA are briefly reviewed. PMID:26032598
48 CFR 209.570-3 - Procedures.
Code of Federal Regulations, 2014 CFR
2014-10-01
... out the use of contracted lead system integrator functions over the shortest period of time consistent... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false Procedures. 209.570-3 Section 209.570-3 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM...
48 CFR 209.570-3 - Procedures.
Code of Federal Regulations, 2013 CFR
2013-10-01
... out the use of contracted lead system integrator functions over the shortest period of time consistent... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Procedures. 209.570-3 Section 209.570-3 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM...
48 CFR 209.570-3 - Procedures.
Code of Federal Regulations, 2012 CFR
2012-10-01
... out the use of contracted lead system integrator functions over the shortest period of time consistent... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false Procedures. 209.570-3 Section 209.570-3 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM...
48 CFR 209.570-3 - Procedures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... out the use of contracted lead system integrator functions over the shortest period of time consistent... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Procedures. 209.570-3 Section 209.570-3 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM...
Pradhan, MR; Taylor, FC; Agrawal, S; Prabhakaran, D; Ebrahim, S
2014-01-01
Background Food habits and choices in India are shifting due to many factors: changing food markets, fast urbanization, food price inflation, uncertain food production and unequal distribution during the past decade. This study aims to explore food acquisition and intra-household consumption patterns in urban low and middle income (LMI) households in Delhi. Methods Twenty households were randomly selected from the Center for Cardio-metabolic Risk Reduction in South Asia (CARRS) surveillance study. Data were derived from 20 questionnaires administered to women responsible for food preparation, four key-informant-interviews, and 20 in-depth interviews with household heads during September-November 2011. STATA and ATLAS.ti software were used for data analysis. Results Half of the households spent at least two-thirds of their income on food. The major expenditures were on vegetables (22% of total food expenditure), milk and milk products (16%), and cereal and related products (15%). Income, food prices, food preferences, and seasonal variation influenced food expenditure. Adults usually ate two to three times a day while children ate more frequently. Eating sequence was based on the work pattern within the household and cultural beliefs. Contrary to previous evidence, there was no gender bias in intra-household food distribution. Women considered food acquisition, preparation and distribution part of their self-worth and played a major role in food related issues in the household. Conclusion Women’s key roles in food acquisition, preparation and intra household food consumption should be considered in formulating food policies and programs. PMID:25473147
High-speed large angle mammography tomosynthesis system
NASA Astrophysics Data System (ADS)
Eberhard, Jeffrey W.; Staudinger, Paul; Smolenski, Joe; Ding, Jason; Schmitz, Andrea; McCoy, Julie; Rumsey, Michael; Al-Khalidy, Abdulrahman; Ross, William; Landberg, Cynthia E.; Claus, Bernhard E. H.; Carson, Paul; Goodsitt, Mitchell; Chan, Heang-Ping; Roubidoux, Marilyn; Thomas, Jerry A.; Osland, Jacqueline
2006-03-01
A new mammography tomosynthesis prototype system that acquires 21 projection images over a 60 degree angular range in approximately 8 seconds has been developed and characterized. Fast imaging sequences are facilitated by a high power tube and generator for faster delivery of the x-ray exposure and a high speed detector read-out. An enhanced a-Si/CsI flat panel digital detector provides greater DQE at low exposure, enabling tomo image sequence acquisitions at total patient dose levels between 150% and 200% of the dose of a standard mammographic view. For clinical scenarios where a single MLO tomographic acquisition per breast may replace the standard CC and MLO views, total tomosynthesis breast dose is comparable to or below the dose in standard mammography. The system supports co-registered acquisition of x-ray tomosynthesis and 3-D ultrasound data sets by incorporating an ultrasound transducer scanning system that flips into position above the compression paddle for the ultrasound exam. Initial images acquired with the system are presented.
Takeshima, Hidenori; Saitoh, Kanako; Nitta, Shuhei; Shiodera, Taichiro; Takeguchi, Tomoyuki; Bannae, Shuhei; Kuhara, Shigehide
2018-03-13
Dynamic MR techniques, such as cardiac cine imaging, benefit from shorter acquisition times. The goal of the present study was to develop a method that achieves short acquisition times, while maintaining a cost-effective reconstruction, for dynamic MRI. k - t sensitivity encoding (SENSE) was identified as the base method to be enhanced meeting these two requirements. The proposed method achieves a reduction in acquisition time by estimating the spatiotemporal (x - f) sensitivity without requiring the acquisition of the alias-free signals, typical of the k - t SENSE technique. The cost-effective reconstruction, in turn, is achieved by a computationally efficient estimation of the x - f sensitivity from the band-limited signals of the aliased inputs. Such band-limited signals are suitable for sensitivity estimation because the strongly aliased signals have been removed. For the same reduction factor 4, the net reduction factor 4 for the proposed method was significantly higher than the factor 2.29 achieved by k - t SENSE. The processing time is reduced from 4.1 s for k - t SENSE to 1.7 s for the proposed method. The image quality obtained using the proposed method proved to be superior (mean squared error [MSE] ± standard deviation [SD] = 6.85 ± 2.73) compared to the k - t SENSE case (MSE ± SD = 12.73 ± 3.60) for the vertical long-axis (VLA) view, as well as other views. In the present study, k - t SENSE was identified as a suitable base method to be improved achieving both short acquisition times and a cost-effective reconstruction. To enhance these characteristics of base method, a novel implementation is proposed, estimating the x - f sensitivity without the need for an explicit scan of the reference signals. Experimental results showed that the acquisition, computational times and image quality for the proposed method were improved compared to the standard k - t SENSE method.
Soper, Tracey
2017-04-01
The aim of this quantitative experimental study was to examine which of three instructional methodologies of traditional lecture, online electronic learning (e-learning) and self-study take-home packets are effective in knowledge acquisition of professional registered nurses. A true experimental design was conducted to contrast the knowledge acquisition of 87 registered nurses randomly selected. A 40-item Acute Coronary Syndrome (ACS) true/false test was used to measure knowledge acquisition. Based on 0.05 significance level, the ANOVA test revealed that there was no difference in knowledge acquisition by registered nurses based on which of three learning instructional method they were assigned. It can be concluded that while all of these instructional methods were equally effective in knowledge acquisition, these methods may not be equally cost- and time-effective. The study was able to determine that there were no significant differences in knowledge acquisition of nurses between the three instructional methodologies. The study also found that all groups scored at the acceptable level for certification. It can be concluded that all of these instructional methods were equally effective in knowledge acquisition but are not equally cost- and time-effective. Therefore, hospital educators may wish to formulate policies regarding choice of instructional method that take into account the efficient use of nurses' time and institutional resources.
Prazeres, Carlos Eduardo Elias Dos; Magalhães, Tiago Augusto; de Castro Carneiro, Adriano Camargo; Cury, Roberto Caldeira; de Melo Moreira, Valéria; Bello, Juliana Hiromi Silva Matsumoto; Rochitte, Carlos Eduardo
The aim of this study was to compare image quality and radiation dose of coronary computed tomography (CT) angiography performed with dual-source CT scanner using 2 different protocols in patients with atrial fibrillation. Forty-seven patients with AF underwent 2 different acquisition protocols: double high-pitch (DHP) spiral acquisition and retrospective spiral acquisition. The image quality was ranked according to a qualitative score by 2 experts: 1, no evident motion; 2, minimal motion not influencing coronary artery luminal evaluation; and 3, motion with impaired luminal evaluation. A third expert solved any disagreement. A total of 732 segments were evaluated. The DHP group (24 patients, 374 segments) showed more segments classified as score 1 than the retrospective spiral acquisition group (71.3% vs 37.4%). Image quality evaluation agreement was high between observers (κ = 0.8). There was significantly lower radiation exposure for the DHP group (3.65 [1.29] vs 23.57 [10.32] mSv). In this original direct comparison, a DHP spiral protocol for coronary CT angiography acquisition in patients with atrial fibrillation resulted in lower radiation exposure and superior image quality compared with conventional spiral retrospective acquisition.
A flexible acquisition cycle for incompletely defined fieldbus protocols.
Gaitan, Vasile-Gheorghita; Gaitan, Nicoleta-Cristina; Ungurean, Ioan
2014-05-01
Real time data-acquisition from fieldbuses strongly depends on the network type and protocol used. Currently, there is an impressive number of fieldbuses, some of them are completely defined and others are incompletely defined. In those from the second category, the time variable, the main element in real-time data acquisition, does not appear explicitly. Examples include protocols such as Modbus ASCII/RTU, M-bus, ASCII character-based, and so on. This paper defines a flexible acquisition cycle based on the Master-Slave architecture that can be implemented on a Master station, called a Base Station Gateway (BSG). The BSG can add a timestamp for temporal location of data. It also presents a possible extension for the Modbus protocol, developed as simple and low cost solution based on existing hardware. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.
Graphical user interface for image acquisition and processing
Goldberg, Kenneth A.
2002-01-01
An event-driven GUI-based image acquisition interface for the IDL programming environment designed for CCD camera control and image acquisition directly into the IDL environment where image manipulation and data analysis can be performed, and a toolbox of real-time analysis applications. Running the image acquisition hardware directly from IDL removes the necessity of first saving images in one program and then importing the data into IDL for analysis in a second step. Bringing the data directly into IDL creates an opportunity for the implementation of IDL image processing and display functions in real-time. program allows control over the available charge coupled device (CCD) detector parameters, data acquisition, file saving and loading, and image manipulation and processing, all from within IDL. The program is built using IDL's widget libraries to control the on-screen display and user interface.
48 CFR 7.107 - Additional requirements for acquisitions involving bundling.
Code of Federal Regulations, 2010 CFR
2010-10-01
... the Government. However, because of the potential impact on small business participation, the head of... performance or efficiency, reduction in acquisition cycle times, better terms and conditions, and any other...; and (2) The acquisition strategy provides for maximum practicable participation by small business...
Cost and Time Overruns for Major Defense Acquisition Programs: An Annotated Brief
2011-04-30
Logistics Management) • Director, Strategic Systems Programs Office • Deputy Director, Acquisition Career Management, US Army • Defense Business...acquisition and industrial base issues and their impact on the transatlantic defense market. Before joining CSIS, he worked as a freelance defense
Development of induction current acquisition device based on ARM
NASA Astrophysics Data System (ADS)
Ji, Yanju; Liu, Xiyang; Huang, Wanyu; Yao, Jiang; Yuan, Guiyang; Hui, Luan; Guan, Shanshan
2018-03-01
We design an induction current acquisition device based on ARM in order to realize high resolution and high sampling rate of acquisition for the induction current in wire-loop. Considering its characteristics of fast attenuation and small signal amplitude, we use the method of multi-path fusion for noise suppression. In the paper, the design is carried out from three aspects of analog circuit and device selection, independent power supply structure and the electromagnetic interference suppression of high frequency. DMA and ping-pong buffer, as a new data transmission technology, solves real time storage problem of massive data. The performance parameters of ARM acquisition device are tested. The comparison test of ARM acquisition device and cRIO acquisition device is performed at different time constants. The results show that it has 120dB dynamic range, 47kHz bandwidth, 96kHz sampling rate, 5μV the smallest resolution, and its average error value is not more than 4%, which proves the high accuracy and stability of the device.
48 CFR 52.243-3 - Changes-Time-and-Materials or Labor-Hours.
Code of Federal Regulations, 2010 CFR
2010-10-01
... performed. (2) Time of performance (i.e., hours of the day, days of the week, etc.). (3) Place of... or Labor-Hours. 52.243-3 Section 52.243-3 Federal Acquisition Regulations System FEDERAL ACQUISITION... Clauses 52.243-3 Changes—Time-and-Materials or Labor-Hours. As prescribed in 43.205(c), insert the...
Stiller, Wolfram; Skornitzke, Stephan; Fritz, Franziska; Klauss, Miriam; Hansen, Jens; Pahn, Gregor; Grenacher, Lars; Kauczor, Hans-Ulrich
2015-10-01
Study objectives were the quantitative evaluation of whether conventional abdominal computed tomography (CT) perfusion measurements mathematically correlate with quantitative single-acquisition dual-energy CT (DECT) iodine concentration maps, the determination of the optimum time of acquisition for achieving maximum correlation, and the estimation of the potential for radiation exposure reduction when replacing conventional CT perfusion by single-acquisition DECT iodine concentration maps. Dual-energy CT perfusion sequences were dynamically acquired over 51 seconds (34 acquisitions every 1.5 seconds) in 24 patients with histologically verified pancreatic carcinoma using dual-source DECT at tube potentials of 80 kVp and 140 kVp. Using software developed in-house, perfusion maps were calculated from 80-kVp image series using the maximum slope model after deformable motion correction. In addition, quantitative iodine maps were calculated for each of the 34 DECT acquisitions per patient. Within a manual segmentation of the pancreas, voxel-by-voxel correlation between the perfusion map and each of the iodine maps was calculated for each patient to determine the optimum time of acquisition topt defined as the acquisition time of the iodine map with the highest correlation coefficient. Subsequently, regions of interest were placed inside the tumor and inside healthy pancreatic tissue, and correlation between mean perfusion values and mean iodine concentrations within these regions of interest at topt was calculated for the patient sample. The mean (SD) topt was 31.7 (5.4) seconds after the start of contrast agent injection. The mean (SD) perfusion values for healthy pancreatic and tumor tissues were 67.8 (26.7) mL per 100 mL/min and 43.7 (32.2) mL per 100 mL/min, respectively. At topt, the mean (SD) iodine concentrations were 2.07 (0.71) mg/mL in healthy pancreatic and 1.69 (0.98) mg/mL in tumor tissue, respectively. Overall, the correlation between perfusion values and iodine concentrations was high (0.77), with correlation of 0.89 in tumor and of 0.56 in healthy pancreatic tissue at topt. Comparing radiation exposure associated with a single DECT acquisition at topt (0.18 mSv) to that of an 80 kVp CT perfusion sequence (2.96 mSv) indicates that an average reduction of Deff by 94% could be achieved by replacing conventional CT perfusion with a single-acquisition DECT iodine concentration map. Quantitative iodine concentration maps obtained with DECT correlate well with conventional abdominal CT perfusion measurements, suggesting that quantitative iodine maps calculated from a single DECT acquisition at an organ-specific and patient-specific optimum time of acquisition might be able to replace conventional abdominal CT perfusion measurements if the time of acquisition is carefully calibrated. This could lead to large reductions of radiation exposure to the patients while offering quantitative perfusion data for diagnosis.
NASA Astrophysics Data System (ADS)
Gu, Chengwei; Zeng, Dong; Lin, Jiahui; Li, Sui; He, Ji; Zhang, Hao; Bian, Zhaoying; Niu, Shanzhou; Zhang, Zhang; Huang, Jing; Chen, Bo; Zhao, Dazhe; Chen, Wufan; Ma, Jianhua
2018-06-01
Myocardial perfusion computed tomography (MPCT) imaging is commonly used to detect myocardial ischemia quantitatively. A limitation in MPCT is that an additional radiation dose is required compared to unenhanced CT due to its repeated dynamic data acquisition. Meanwhile, noise and streak artifacts in low-dose cases are the main factors that degrade the accuracy of quantifying myocardial ischemia and hamper the diagnostic utility of the filtered backprojection reconstructed MPCT images. Moreover, it is noted that the MPCT images are composed of a series of 2/3D images, which can be naturally regarded as a 3/4-order tensor, and the MPCT images are globally correlated along time and are sparse across space. To obtain higher fidelity ischemia from low-dose MPCT acquisitions quantitatively, we propose a robust statistical iterative MPCT image reconstruction algorithm by incorporating tensor total generalized variation (TTGV) regularization into a penalized weighted least-squares framework. Specifically, the TTGV regularization fuses the spatial correlation of the myocardial structure and the temporal continuation of the contrast agent intake during the perfusion. Then, an efficient iterative strategy is developed for the objective function optimization. Comprehensive evaluations have been conducted on a digital XCAT phantom and a preclinical porcine dataset regarding the accuracy of the reconstructed MPCT images, the quantitative differentiation of ischemia and the algorithm’s robustness and efficiency.
Parallel multispot smFRET analysis using an 8-pixel SPAD array
NASA Astrophysics Data System (ADS)
Ingargiola, A.; Colyer, R. A.; Kim, D.; Panzeri, F.; Lin, R.; Gulinatti, A.; Rech, I.; Ghioni, M.; Weiss, S.; Michalet, X.
2012-02-01
Single-molecule Förster resonance energy transfer (smFRET) is a powerful tool for extracting distance information between two fluorophores (a donor and acceptor dye) on a nanometer scale. This method is commonly used to monitor binding interactions or intra- and intermolecular conformations in biomolecules freely diffusing through a focal volume or immobilized on a surface. The diffusing geometry has the advantage to not interfere with the molecules and to give access to fast time scales. However, separating photon bursts from individual molecules requires low sample concentrations. This results in long acquisition time (several minutes to an hour) to obtain sufficient statistics. It also prevents studying dynamic phenomena happening on time scales larger than the burst duration and smaller than the acquisition time. Parallelization of acquisition overcomes this limit by increasing the acquisition rate using the same low concentrations required for individual molecule burst identification. In this work we present a new two-color smFRET approach using multispot excitation and detection. The donor excitation pattern is composed of 4 spots arranged in a linear pattern. The fluorescent emission of donor and acceptor dyes is then collected and refocused on two separate areas of a custom 8-pixel SPAD array. We report smFRET measurements performed on various DNA samples synthesized with various distances between the donor and acceptor fluorophores. We demonstrate that our approach provides identical FRET efficiency values to a conventional single-spot acquisition approach, but with a reduced acquisition time. Our work thus opens the way to high-throughput smFRET analysis on freely diffusing molecules.
Ku-band signal design study. [for space shuttle orbiter communication links
NASA Technical Reports Server (NTRS)
Lindsey, W. L.; Woo, K. T.
1977-01-01
The acquisition/tracking performance of a practical squaring loop in which the times two multiplier is mechanized as a limiter/multiplier combination is evaluated. This squaring approach serves to produce the absolute value of the arriving signal as opposed to the perfect square law action which is required in order to render acquisition and tracking performance equivalent to that of a Costas loop. The Ku-Band orbiter signal design for the forward link is assessed. Acquisition time results and acquisition and tracking thresholds are summarized. A tradeoff study which pertains to bit synchronization techniques for the high rate Ku-Band channel is included and an optimum selection is made based upon the appropriate design constraints.
ERIC Educational Resources Information Center
Gallego, Muriel
2016-01-01
The present study investigates whether the implementation of a dictogloss task within a proactive Focus on Form approach (e.g., Long 1991; Long and Robinson 1998) has significant effects on the acquisition of Spanish present subjunctive. A total of sixty-six learners in a fifth-semester Spanish course participated in the study and were assigned to…
Using Cost as an Independent Variable (CAIV) to Reduce Total Ownership Cost
2006-01-31
and the online Guidebook’s best practices provide policy and process guidance for preparation of user-required capabilities (CJCS 3170 series ), along...of new JROC/JCIDS processes nor engendering full leadership support to reduce O&S costs. The Program Manager (PM) is responsible for developing and...warfighting systems? The Under Secretary of Defense for Acquisition, Technology and Logistics (USD (AT&L)) published new acquisition policy and
ERIC Educational Resources Information Center
Tynan, Mark; McCarney, Eoin
2014-01-01
University College Dublin became the first library in the Republic of Ireland to trial patron-driven acquisition (PDA) as a collection development tool in 2013. A total of 42% of UCD Library's book budget was allocated to the project, which included both electronic and print books. This article describes the twelve month project from the tender…
Organ procurement expenditures and the role of financial incentives.
Evans, R W
To evaluate the billed charges for organ procurement and to consider the role of financial incentives to encourage organ donation. Observational study. Data were obtained on donor organ acquisition charges from a random sample of kidney, heart, liver, heart-lung, and pancreas transplants. The data were based on 28.7% of all transplants performed in the United States in 1988. Total charges for donor organ acquisition. The median charges (1988 dollars) for donor organs were as follows: kidney, $12,290; heart, $12,578; liver, $16,281; heart-lung, $12,028; and pancreas, $15,400. Since 1983, kidney acquisition charges have increased by 12.9%, heart charges by 64.1%, and liver charges by 61.8%, after adjusting for inflation. Between 9% and 31% of total transplant procedure-specific charges were associated with donor organ acquisition. There is wide unexplained variation in organ procurement charges. Data on actual costs are required to establish the appropriateness of current charges. Prevailing billing and payment methods should be reevaluated in an effort to address a variety of issues related to reimbursement. Current payment methods may actually contribute to cost inefficiency. Finally, while financial incentives may enhance the efficiency of organ procurement efforts, they will adversely affect the cost-effectiveness of transplantation.
48 CFR 9.505-2 - Preparing specifications or work statements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... ACQUISITION REGULATION ACQUISITION PLANNING CONTRACTOR QUALIFICATIONS Organizational and Consultant Conflicts... subcontractor, for a reasonable period of time including, at least, the duration of the initial production... eliminated for a reasonable time from competition for production based on the specifications. This should be...
48 CFR 9.505-2 - Preparing specifications or work statements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... ACQUISITION REGULATION ACQUISITION PLANNING CONTRACTOR QUALIFICATIONS Organizational and Consultant Conflicts... subcontractor, for a reasonable period of time including, at least, the duration of the initial production... eliminated for a reasonable time from competition for production based on the specifications. This should be...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Policy. 1601.301 Section... Regulation (FEHBAR) 1601.301 Policy. (a) Procedures, contract clauses, and other aspects of the acquisition... policies and procedures contained in this regulation as implemented and supplemented from time to time; and...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Policy. 1601.301 Section... Regulation (FEHBAR) 1601.301 Policy. (a) Procedures, contract clauses, and other aspects of the acquisition... policies and procedures contained in this regulation as implemented and supplemented from time to time; and...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Policy. 1601.301 Section... Regulation (FEHBAR) 1601.301 Policy. (a) Procedures, contract clauses, and other aspects of the acquisition... policies and procedures contained in this regulation as implemented and supplemented from time to time; and...
Gousse, A E; Barbaric, Z L; Safir, M H; Madjar, S; Marumoto, A K; Raz, S
2000-11-01
We assessed the merit of dynamic half Fourier acquisition, single shot turbo spin-echo sequence T2-weighted magnetic resonance imaging (MRI) for evaluating pelvic organ prolapse and all other female pelvic pathology by prospectively correlating clinical with imaging findings. From September 1997 to April 1998, 100 consecutive women 23 to 88 years old with (65) and without (35) pelvic organ prolapse underwent half Fourier acquisition, single shot turbo spin-echo sequence dynamic pelvic T2-weighted MRI at our institution using a 1.5 Tesla magnet with phased array coils. Mid sagittal and parasagittal views with the patient supine, relaxed and straining were obtained using no pre-examination preparation or instrumentation. We evaluated the anterior vaginal wall, bladder, urethra, posterior vaginal wall, rectum, pelvic floor musculature, perineum, uterus, vaginal cuff, ovaries, ureters and intraperitoneal organs for all pathological conditions, including pelvic prolapse. Patients underwent a prospective physical examination performed by a female urologist, and an experienced radiologist blinded to pre-imaging clinical findings interpreted all studies. Physical examination, MRI and intraoperative findings were statistically correlated. Total image acquisition time was 2.5 minutes, room time 10 minutes and cost American $540. Half Fourier acquisition, single shot turbo spin-echo T2-weighted MRI revealed pathological entities other than pelvic prolapse in 55 cases, including uterine fibroids in 11, ovarian cysts in 9, bilateral ureteronephrosis in 3, nabothian cyst in 7, Bartholin's gland cyst in 4, urethral diverticulum in 3, polytetrafluoroethylene graft abscess in 3, bladder diverticulum in 2, sacral spinal abnormalities in 2, bladder tumor in 1, sigmoid diverticulosis in 1 and other in 9. Intraoperative findings were considered the gold standard against which physical examination and MRI were compared. Using these criteria the sensitivity, specificity and positive predictive value of MRI were 100%, 83% and 97% for cystocele; 100%, 75% and 94% for urethrocele; 100%, 54% and 33% for vaginal vault prolapse; 83%, 100% and 100% for uterine prolapse; 87%, 80% and 91% for enterocele; and 76%, 50% and 96% for rectocele. Dynamic half Fourier acquisition, single shot turbo spin-echo MRI appears to be an important adjunct in the comprehensive evaluation of the female pelvis. Except for rectocele, pelvic floor prolapse is accurately staged and pelvic organ pathology reliably detected. The technique is rapid, noninvasive and cost-effective, and it allows the clinician to visualize the whole pelvis using a single dynamic study that provides superb anatomical detail.
48 CFR 52.232-13 - Notice of Progress Payments.
Code of Federal Regulations, 2010 CFR
2010-10-01
... be inoperative during any time the contractor's accounting system and controls are determined by the... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false Notice of Progress Payments. 52.232-13 Section 52.232-13 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION...
[Real time 3D echocardiography
NASA Technical Reports Server (NTRS)
Bauer, F.; Shiota, T.; Thomas, J. D.
2001-01-01
Three-dimensional representation of the heart is an old concern. Usually, 3D reconstruction of the cardiac mass is made by successive acquisition of 2D sections, the spatial localisation and orientation of which require complex guiding systems. More recently, the concept of volumetric acquisition has been introduced. A matricial emitter-receiver probe complex with parallel data processing provides instantaneous of a pyramidal 64 degrees x 64 degrees volume. The image is restituted in real time and is composed of 3 planes (planes B and C) which can be displaced in all spatial directions at any time during acquisition. The flexibility of this system of acquisition allows volume and mass measurement with greater accuracy and reproducibility, limiting inter-observer variability. Free navigation of the planes of investigation allows reconstruction for qualitative and quantitative analysis of valvular heart disease and other pathologies. Although real time 3D echocardiography is ready for clinical usage, some improvements are still necessary to improve its conviviality. Then real time 3D echocardiography could be the essential tool for understanding, diagnosis and management of patients.
NASA Astrophysics Data System (ADS)
Ishigaki, Tsukasa; Yamamoto, Yoshinobu; Nakamura, Yoshiyuki; Akamatsu, Motoyuki
Patients that have an health service by doctor have to wait long time at many hospitals. The long waiting time is the worst factor of patient's dissatisfaction for hospital service according to questionnaire for patients. The present paper describes an estimation method of the waiting time for each patient without an electronic medical chart system. The method applies a portable RFID system to data acquisition and robust estimation of probability distribution of the health service and test time by doctor for high-accurate waiting time estimation. We carried out an health service of data acquisition at a real hospital and verified the efficiency of the proposed method. The proposed system widely can be used as data acquisition system in various fields such as marketing service, entertainment or human behavior measurement.
Wickham, Fred; McMeekin, Helena; Burniston, Maria; McCool, Daniel; Pencharz, Deborah; Skillen, Annah; Wagner, Thomas
2017-12-01
The purpose of this study is to identify a method for optimising the administered activity and acquisition time for 18 F-FDG PET imaging, yielding images of consistent quality for patients with varying body sizes and compositions, while limiting radiation doses to patients and staff. Patients referred for FDG scans had bioimpedance measurements. They were injected with 3 MBq/kg of 18 F up to 370 MBq and scanned on a Siemens Biograph mCT at 3 or 4 min per bed position. Data were rebinned to simulate 2- and 1-min acquisitions. Subjective assessments of image quality made by an experienced physician were compared with objective measurements based on signal-to-noise ratio and noise equivalent counts (NEC). A target objective measure of image quality was identified. The activity and acquisition time required to achieve this were calculated for each subject. Multiple regression analysis was used to identify expressions for the activity and acquisition time required in terms of easily measurable patient characteristics. One hundred and eleven patients were recruited, and subjective and objective assessments of image quality were compared for 321 full and reduced time scans. NEC-per-metre was identified as the objective measure which best correlated with the subjective assessment (Spearman rank correlation coefficient 0.77) and the best discriminator for images with a subjective assessment of "definitely adequate" (area under the ROC curve 0.94). A target of 37 Mcount/m was identified. Expressions were identified in terms of patient sex, height and weight for the activity and acquisition time required to achieve this target. Including measurements of body composition in these expressions was not useful. Using these expressions would reduce the mean activity administered to this patient group by 66 MBq compared to the current protocol. Expressions have been identified for the activity and acquisition times required to achieve consistent image quality in FDG imaging with reduced patient and staff doses. These expressions might need to be adapted for other systems and reconstruction protocols.
Real-time data acquisition and control system for the measurement of motor and neural data
Bryant, Christopher L.; Gandhi, Neeraj J.
2013-01-01
This paper outlines a powerful, yet flexible real-time data acquisition and control system for use in the triggering and measurement of both analog and digital events. Built using the LabVIEW development architecture (version 7.1) and freely available, this system provides precisely timed auditory and visual stimuli to a subject while recording analog data and timestamps of neural activity retrieved from a window discriminator. The system utilizes the most recent real-time (RT) technology in order to provide not only a guaranteed data acquisition rate of 1 kHz, but a much more difficult to achieve guaranteed system response time of 1 ms. The system interface is windows-based and easy to use, providing a host of configurable options for end-user customization. PMID:15698659
Non-contact single shot elastography using line field low coherence holography
Liu, Chih-Hao; Schill, Alexander; Wu, Chen; Singh, Manmohan; Larin, Kirill V.
2016-01-01
Optical elastic wave imaging is a powerful technique that can quantify local biomechanical properties of tissues. However, typically long acquisition times make this technique unfeasible for clinical use. Here, we demonstrate non-contact single shot elastographic holography using a line-field interferometer integrated with an air-pulse delivery system. The propagation of the air-pulse induced elastic wave was imaged in real time, and required a single excitation for a line-scan measurement. Results on tissue-mimicking phantoms and chicken breast muscle demonstrated the feasibility of this technique for accurate assessment of tissue biomechanical properties with an acquisition time of a few milliseconds using parallel acquisition. PMID:27570694
Jan, Shau-Shiun; Sun, Chih-Cheng
2010-01-01
The detection of low received power of global positioning system (GPS) signals in the signal acquisition process is an important issue for GPS applications. Improving the miss-detection problem of low received power signal is crucial, especially for urban or indoor environments. This paper proposes a signal existence verification (SEV) process to detect and subsequently verify low received power GPS signals. The SEV process is based on the time-frequency representation of GPS signal, and it can capture the characteristic of GPS signal in the time-frequency plane to enhance the GPS signal acquisition performance. Several simulations and experiments are conducted to show the effectiveness of the proposed method for low received power signal detection. The contribution of this work is that the SEV process is an additional scheme to assist the GPS signal acquisition process in low received power signal detection, without changing the original signal acquisition or tracking algorithms.
Revise and resubmit: How real-time parsing limitations influence grammar acquisition
Pozzan, Lucia; Trueswell, John C.
2015-01-01
We present the results from a three-day artificial language learning study on adults. The study examined whether sentence-parsing limitations, in particular, difficulties revising initial syntactic/semantic commitments during comprehension, shape learners’ ability to acquire a language. Findings show that both comprehension and production of morphology pertaining to sentence argument structure are delayed when this morphology consistently appears at the end, rather than at the beginning, of sentences in otherwise identical grammatical systems. This suggests that real-time processing constraints impact acquisition; morphological cues that tend to guide linguistic analyses are easier to learn than cues that revise these analyses. Parallel performance in production and comprehension indicates that parsing constraints affect grammatical acquisition, not just real-time commitments. Properties of the linguistic system (e.g., ordering of cues within a sentence) interact with the properties of the cognitive system (cognitive control and conflict-resolution abilities) and together affect language acquisition. PMID:26026607
Data acquisition and readout system for the LUX dark matter experiment
Akerib, D. S.; Bai, X.; Bedikian, S.; ...
2011-11-28
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils from interactions with dark matter particles. Signals from the LUX detector are processed by custom-built analog electronics which provide properly shaped signals for the trigger and data acquisition (DAQ) systems. The DAQ is comprised of commercial digitizers with firmware customized for the LUX experiment. Data acquisition systems in rare-event searches must accommodate high rate and large dynamic range during precision calibrations involving radioactive sources, while also delivering low threshold for maximum sensitivity. The LUX DAQ meets these challenges using real-time baseline sup- pression that allows formore » a maximum event acquisition rate in excess of 1.5 kHz with virtually no deadtime. This work describes the LUX DAQ and the novel acquisition techniques employed in the LUX experiment.« less
Acquisition performance of LAPAN-A3/IPB multispectral imager in real-time mode of operation
NASA Astrophysics Data System (ADS)
Hakim, P. R.; Permala, R.; Jayani, A. P. S.
2018-05-01
LAPAN-A3/IPB satellite was launched in June 2016 and its multispectral imager has been producing Indonesian coverage images. In order to improve its support for remote sensing application, the imager should produce images with high quality and quantity. To improve the quantity of LAPAN-A3/IPB multispectral image captured, image acquisition could be executed in real-time mode from LAPAN ground station in Bogor when the satellite passes west Indonesia region. This research analyses the performance of LAPAN-A3/IPB multispectral imager acquisition in real-time mode, in terms of image quality and quantity, under assumption of several on-board and ground segment limitations. Results show that with real-time operation mode, LAPAN-A3/IPB multispectral imager could produce twice as much as image coverage compare to recorded mode. However, the images produced in real-time mode will have slightly degraded quality due to image compression process involved. Based on several analyses that have been done in this research, it is recommended to use real-time acquisition mode whenever it possible, unless for some circumstances that strictly not allow any quality degradation of the images produced.
Haider, Clifton R; Borisch, Eric A; Glockner, James F; Mostardi, Petrice M; Rossman, Phillip J; Young, Phillip M; Riederer, Stephen J
2010-10-01
High temporal and spatial resolution is desired in imaging of vascular abnormalities having short arterial-to-venous transit times. Methods that exploit temporal correlation to reduce the observed frame time demonstrate temporal blurring, obfuscating bolus dynamics. Previously, a Cartesian acquisition with projection reconstruction-like (CAPR) sampling method has been demonstrated for three-dimensional contrast-enhanced angiographic imaging of the lower legs using two-dimensional sensitivity-encoding acceleration and partial Fourier acceleration, providing 1mm isotropic resolution of the calves, with 4.9-sec frame time and 17.6-sec temporal footprint. In this work, the CAPR acquisition is further undersampled to provide a net acceleration approaching 40 by eliminating all view sharing. The tradeoff of frame time and temporal footprint in view sharing is presented and characterized in phantom experiments. It is shown that the resultant 4.9-sec acquisition time, three-dimensional images sets have sufficient spatial and temporal resolution to clearly portray arterial and venous phases of contrast passage. It is further hypothesized that these short temporal footprint sequences provide diagnostic quality images. This is tested and shown in a series of nine contrast-enhanced MR angiography patient studies performed with the new method.
Sensitivity-encoded (SENSE) proton echo-planar spectroscopic imaging (PEPSI) in the human brain.
Lin, Fa-Hsuan; Tsai, Shang-Yueh; Otazo, Ricardo; Caprihan, Arvind; Wald, Lawrence L; Belliveau, John W; Posse, Stefan
2007-02-01
Magnetic resonance spectroscopic imaging (MRSI) provides spatially resolved metabolite information that is invaluable for both neuroscience studies and clinical applications. However, lengthy data acquisition times, which are a result of time-consuming phase encoding, represent a major challenge for MRSI. Fast MRSI pulse sequences that use echo-planar readout gradients, such as proton echo-planar spectroscopic imaging (PEPSI), are capable of fast spectral-spatial encoding and thus enable acceleration of image acquisition times. Combining PEPSI with recent advances in parallel MRI utilizing RF coil arrays can further accelerate MRSI data acquisition. Here we investigate the feasibility of ultrafast spectroscopic imaging at high field (3T and 4T) by combining PEPSI with sensitivity-encoded (SENSE) MRI using eight-channel head coil arrays. We show that the acquisition of single-average SENSE-PEPSI data at a short TE (15 ms) can be accelerated to 32 s or less, depending on the field strength, to obtain metabolic images of choline (Cho), creatine (Cre), N-acetyl-aspartate (NAA), and J-coupled metabolites (e.g., glutamate (Glu) and inositol (Ino)) with acceptable spectral quality and localization. The experimentally measured reductions in signal-to-noise ratio (SNR) and Cramer-Rao lower bounds (CRLBs) of metabolite resonances were well explained by both the g-factor and reduced measurement times. Thus, this technology is a promising means of reducing the scan times of 3D acquisitions and time-resolved 2D measurements. Copyright (c) 2007 Wiley-Liss, Inc.
NASA Technical Reports Server (NTRS)
Martin, David S.; Borowski, Allan; Bungo, Michael W.; Gladding, Patrick; Greenberg, Neil; Hamilton, Doug; Levine, Benjamin D.; Lee, Stuart M.; Norwood, Kelly; Platts, Steven H.;
2012-01-01
Methods: In the year before launch of an ISS mission, potential astronaut echocardiographic operators participate in 5 sessions to train for echo acquisitions that occur roughly monthly during the mission, including one exercise echocardiogram. The focus of training is familiarity with the study protocol and remote guidance procedures. On-orbit, real-time guidance of in-flight acquisitions is provided by a sonographer in the Telescience Center of Mission Control. Physician investigators with remote access are able to relay comments on image quality to the sonographer. Live video feed is relayed from the ISS to the ground via the Tracking and Data Relay Satellite System with a 2- second transmission delay. The expert sonographer uses these images, along with twoway audio, to provide instructions and feedback. Images are stored in non-compressed DICOM format for asynchronous relay to the ground for subsequent off-line analysis. Results: Since June, 2009, a total of 27 resting echocardiograms and 5 exercise studies have been performed during flight. Average acquisition time has been 45 minutes, reflecting 26,000 km of ISS travel per study. Image quality has been adequate in all studies, and remote guidance has proven imperative for fine-tuning imaging and prioritizing views when communication outages limit the study duration. Typical resting studies have included 27 video loops and 30 still-frame images requiring 750 MB of storage. Conclusions: Despite limited crew training, remote guidance allows research-quality echocardiography to be performed by non-experts aboard the ISS. Analysis is underway and additional subjects are being recruited to define the impact of microgravity on cardiac structure and systolic and diastolic function.
Imaging skills for transthoracic echocardiography in cardiology fellows: The value of motion metrics
Montealegre-Gallegos, Mario; Mahmood, Feroze; Kim, Han; Bergman, Remco; Mitchell, John D.; Bose, Ruma; Hawthorne, Katie M.; O’Halloran, T. David; Wong, Vanessa; Hess, Philip E.; Matyal, Robina
2016-01-01
Background: Proficiency in transthoracic echocardiography (TTE) requires an integration of cognitive knowledge and psychomotor skills. Whereas cognitive knowledge can be quantified, psychomotor skills are implied after repetitive task performance. We applied motion analyses to evaluate psychomotor skill acquisition during simulator-based TTE training. Methods and Results: During the first month of their fellowship training, 16 cardiology fellows underwent a multimodal TTE training program for 4 weeks (8 sessions). The program consisted of online and live didactics as well as simulator training. Kinematic metrics (path length, time, probe accelerations) were obtained at the start and end of the course for 8 standard TTE views using a simulator. At the end of the course TTE image acquisition skills were tested on human models. After completion of the training program the trainees reported improved self-perceived comfort with TTE imaging. There was also an increase of 8.7% in post-test knowledge scores. There was a reduction in the number of probe accelerations [median decrease 49.5, 95% CI = 29-73, adjusted P < 0.01], total time [median decrease 10.6 s, 95% CI = 6.6-15.5, adjusted P < 0.01] and path length [median decrease 8.8 cm, 95% CI = 2.2-17.7, adjusted P < 0.01] from the start to the end of the course. During evaluation on human models, the trainees were able to obtain all the required TTE views without instructor assistance. Conclusion: Simulator-derived motion analyses can be used to objectively quantify acquisition of psychomotor skills during TTE training. Such an approach could be used to assess readiness for clinical practice of TTE. PMID:27052064
Hayes, Don; West, Susan E; Rock, Michael J; Li, Zhanhai; Splaingard, Mark L; Farrell, Philip M
2010-07-01
Chronic pulmonary infection with Pseudomonas aeruginosa (PA) is responsible for significant morbidity and mortality in cystic fibrosis (CF). Because of the limited studies evaluating early exposure and the progression of genetic variability of PA, our goal was to assess PA in young children with CF followed in two clinic types. A total of 39 infants with CF diagnosed through newborn screening were randomly assigned to either a segregated (PA-free) or mixed (PA-positive) clinic at two different CF centers, one of which replaced an older, mixed clinic where nosocomial acquisition was suspected. Oropharyngeal (OP) swab cultures were examined with subsequent genotyping to characterize the strains of PA isolated. We found that 13/21 segregated clinic patients and 14/18 mixed clinic patients showed positive PA, with median acquisition ages of 3.3 and 2.2 years, respectively (P = 0.57). The median time to PA acquisition, however, was significantly longer in the new clinic with proper hygiene precautions compared to an old site (5.0 years vs. 1.7 years, P < 0.001). The majority of subjects isolated a single genotype of PA or AP-PCR types during the study period with eight subjects clearing the isolate after only one positive culture. The development of chronic colonization yielded the predominance of a single major genotype or AP-PCR type. Segregation of infants and young children with CF in PA-negative or PA-positive clinics did not alter the time to first PA isolation in this randomized assessment of facilities with hygienic precautions. During the early infection period where PA is first isolated in young children with CF, patients cleared different PA strains until a predominant strain established permanent colonization.
NASA Astrophysics Data System (ADS)
Foltynowicz, Aleksandra; Rutkowski, Lucile; Johanssson, Alexandra C.; Khodabakhsh, Amir; Maslowski, Piotr; Kowzan, Grzegorz; Lee, Kevin; Fermann, Martin
2015-06-01
Fourier transform spectrometers (FTS) based on optical frequency combs (OFC) allow detection of broadband molecular spectra with high signal-to-noise ratios within acquisition times orders of magnitude shorter than traditional FTIRs based on thermal sources. Due to the pulsed nature of OFCs the interferogram consists of a series of bursts rather than a single burst at zero optical path difference (OPD). The comb mode structure can be resolved by acquiring multiple bursts, in both mechanical FTS systems and dual-comb spectroscopy. However, in all existing demonstrations the resolution was ultimately limited either by the maximum available OPD between the interferometer arms or by the total acquisition time enabled by the storage memory. We present a method that provides spectral resolution exceeding the limit set by the maximum OPD using an interferogram containing only a single burst. The method allows measurements of absorption lines narrower than the OPD-limited resolution without any influence of the instrumental lineshape function. We demonstrate this by measuring undistorted CO2 and CO absorption lines with linewidth narrower than the OPD-limited resolution using OFC-based mechanical FTS in the near- and mid-infrared wavelength ranges. The near-infrared system is based on an Er:fiber femtosecond laser locked to a high finesse cavity, while the mid-infrared system is based on a Tm:fiber-laser-pumped optical parametric oscillator coupled to a multi-pass cell. We show that the method allows acquisition of high-resolution molecular spectra with interferometer length orders of magnitude shorter than traditional FTIR. Mandon, J., G. Guelachvili, and N. Picque, Nat. Phot., 2009. 3(2): p. 99-102. Zeitouny, M., et al., Ann. Phys., 2013. 525(6): p. 437-442. Zolot, A.M., et al., Opt. Lett., 2012. 37(4): p. 638-640.
Parallel Spectral Acquisition with an Ion Cyclotron Resonance Cell Array.
Park, Sung-Gun; Anderson, Gordon A; Navare, Arti T; Bruce, James E
2016-01-19
Mass measurement accuracy is a critical analytical figure-of-merit in most areas of mass spectrometry application. However, the time required for acquisition of high-resolution, high mass accuracy data limits many applications and is an aspect under continual pressure for development. Current efforts target implementation of higher electrostatic and magnetic fields because ion oscillatory frequencies increase linearly with field strength. As such, the time required for spectral acquisition of a given resolving power and mass accuracy decreases linearly with increasing fields. Mass spectrometer developments to include multiple high-resolution detectors that can be operated in parallel could further decrease the acquisition time by a factor of n, the number of detectors. Efforts described here resulted in development of an instrument with a set of Fourier transform ion cyclotron resonance (ICR) cells as detectors that constitute the first MS array capable of parallel high-resolution spectral acquisition. ICR cell array systems consisting of three or five cells were constructed with printed circuit boards and installed within a single superconducting magnet and vacuum system. Independent ion populations were injected and trapped within each cell in the array. Upon filling the array, all ions in all cells were simultaneously excited and ICR signals from each cell were independently amplified and recorded in parallel. Presented here are the initial results of successful parallel spectral acquisition, parallel mass spectrometry (MS) and MS/MS measurements, and parallel high-resolution acquisition with the MS array system.
Bullich, Santiago; Barthel, Henryk; Koglin, Norman; Becker, Georg A; De Santi, Susan; Jovalekic, Aleksandar; Stephens, Andrew W; Sabri, Osama
2017-11-24
Accurate amyloid PET quantification is necessary for monitoring amyloid-beta accumulation and response to therapy. Currently, most of the studies are analyzed using the static standardized uptake value ratio (SUVR) approach because of its simplicity. However, this approach may be influenced by changes in cerebral blood flow (CBF) or radiotracer clearance. Full tracer kinetic models require arterial blood sampling and dynamic image acquisition. The objectives of this work were: (1) to validate a non-invasive kinetic modeling approach for 18 F-florbetaben PET using an acquisition protocol with the best compromise between quantification accuracy and simplicity and (2) to assess the impact of CBF changes and radiotracer clearance on SUVRs and non-invasive kinetic modeling data in 18 F-florbetaben PET. Methods: Data from twenty subjects (10 patients with probable Alzheimer's dementia/ 10 healthy volunteers) were used to compare the binding potential (BP ND ) obtained from the full kinetic analysis to the SUVR and to non-invasive tracer kinetic methods (simplified reference tissue model (SRTM), and multilinear reference tissue model 2 (MRTM2)). Different approaches using shortened or interrupted acquisitions were compared to the results of the full acquisition (0-140 min). Simulations were carried out to assess the effect of CBF and radiotracer clearance changes on SUVRs and non-invasive kinetic modeling outputs. Results: A 0-30 and 120-140 min dual time-window acquisition protocol using appropriate interpolation of the missing time points provided the best compromise between patient comfort and quantification accuracy. Excellent agreement was found between BP ND obtained using full and dual time-window (2TW) acquisition protocols (BP ND,2TW =0.01+ 1.00 BP ND,FULL , R2=0.97 (MRTM2); BP ND,2TW = 0.05+ 0.92·BP ND,FULL , R2=0.93 (SRTM)). Simulations showed a limited impact of CBF and radiotracer clearance changes on MRTM parameters and SUVRs. Conclusion: This study demonstrates accurate non-invasive kinetic modeling of 18 F-florbetaben PET data using a dual time-window acquisition protocol, thus providing a good compromise between quantification accuracy, scan duration and patient burden. The influence of CBF and radiotracer clearance changes on amyloid-beta load estimates was small. For most clinical research applications, the SUVR approach is appropriate. However, for longitudinal studies in which a maximum quantification accuracy is desired, this non-invasive dual time-window acquisition protocol and kinetic analysis is recommended. Copyright © 2017 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Fast imaging of laboratory core floods using 3D compressed sensing RARE MRI.
Ramskill, N P; Bush, I; Sederman, A J; Mantle, M D; Benning, M; Anger, B C; Appel, M; Gladden, L F
2016-09-01
Three-dimensional (3D) imaging of the fluid distributions within the rock is essential to enable the unambiguous interpretation of core flooding data. Magnetic resonance imaging (MRI) has been widely used to image fluid saturation in rock cores; however, conventional acquisition strategies are typically too slow to capture the dynamic nature of the displacement processes that are of interest. Using Compressed Sensing (CS), it is possible to reconstruct a near-perfect image from significantly fewer measurements than was previously thought necessary, and this can result in a significant reduction in the image acquisition times. In the present study, a method using the Rapid Acquisition with Relaxation Enhancement (RARE) pulse sequence with CS to provide 3D images of the fluid saturation in rock core samples during laboratory core floods is demonstrated. An objective method using image quality metrics for the determination of the most suitable regularisation functional to be used in the CS reconstructions is reported. It is shown that for the present application, Total Variation outperforms the Haar and Daubechies3 wavelet families in terms of the agreement of their respective CS reconstructions with a fully-sampled reference image. Using the CS-RARE approach, 3D images of the fluid saturation in the rock core have been acquired in 16min. The CS-RARE technique has been applied to image the residual water saturation in the rock during a water-water displacement core flood. With a flow rate corresponding to an interstitial velocity of vi=1.89±0.03ftday(-1), 0.1 pore volumes were injected over the course of each image acquisition, a four-fold reduction when compared to a fully-sampled RARE acquisition. Finally, the 3D CS-RARE technique has been used to image the drainage of dodecane into the water-saturated rock in which the dynamics of the coalescence of discrete clusters of the non-wetting phase are clearly observed. The enhancement in the temporal resolution that has been achieved using the CS-RARE approach enables dynamic transport processes pertinent to laboratory core floods to be investigated in 3D on a time-scale and with a spatial resolution that, until now, has not been possible. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Cross, Russell; Olivieri, Laura; O'Brien, Kendall; Kellman, Peter; Xue, Hui; Hansen, Michael
2016-02-25
Traditional cine imaging for cardiac functional assessment requires breath-holding, which can be problematic in some situations. Free-breathing techniques have relied on multiple averages or real-time imaging, producing images that can be spatially and/or temporally blurred. To overcome this, methods have been developed to acquire real-time images over multiple cardiac cycles, which are subsequently motion corrected and reformatted to yield a single image series displaying one cardiac cycle with high temporal and spatial resolution. Application of these algorithms has required significant additional reconstruction time. The use of distributed computing was recently proposed as a way to improve clinical workflow with such algorithms. In this study, we have deployed a distributed computing version of motion corrected re-binning reconstruction for free-breathing evaluation of cardiac function. Twenty five patients and 25 volunteers underwent cardiovascular magnetic resonance (CMR) for evaluation of left ventricular end-systolic volume (ESV), end-diastolic volume (EDV), and end-diastolic mass. Measurements using motion corrected re-binning were compared to those using breath-held SSFP and to free-breathing SSFP with multiple averages, and were performed by two independent observers. Pearson correlation coefficients and Bland-Altman plots tested agreement across techniques. Concordance correlation coefficient and Bland-Altman analysis tested inter-observer variability. Total scan plus reconstruction times were tested for significant differences using paired t-test. Measured volumes and mass obtained by motion corrected re-binning and by averaged free-breathing SSFP compared favorably to those obtained by breath-held SSFP (r = 0.9863/0.9813 for EDV, 0.9550/0.9685 for ESV, 0.9952/0.9771 for mass). Inter-observer variability was good with concordance correlation coefficients between observers across all acquisition types suggesting substantial agreement. Both motion corrected re-binning and averaged free-breathing SSFP acquisition and reconstruction times were shorter than breath-held SSFP techniques (p < 0.0001). On average, motion corrected re-binning required 3 min less than breath-held SSFP imaging, a 37% reduction in acquisition and reconstruction time. The motion corrected re-binning image reconstruction technique provides robust cardiac imaging that can be used for quantification that compares favorably to breath-held SSFP as well as multiple average free-breathing SSFP, but can be obtained in a fraction of the time when using cloud-based distributed computing reconstruction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bharoto,; Suparno, Nadi; Putra, Edy Giri Rachman
In 2005, the main computer for data acquisition and control system of Small-angle Neutron Scattering (SANS) BATAN Spectrometer (SMARTer) was replaced since it halted to operate the spectrometer. According to this replacement, the new software for data acquisition and control system has been developed in-house. Visual Basic programming language is used in developing the software. In the last two years, many developments have been made both in the hardware and also the software to conduct the experiment is more effective and efficient. Lately, the previous motor controller card (ISA Card) was replaced with the programmable motor controller card (PCI Card)more » for driving one motor of position sensitive detector (PSD), eight motors of four collimators, and six motors of six pinhole discs. This new control system software makes all motors can be moved simultaneously, then it reduces significantly the consuming time of setting up the instrument before running the experiment. Along with that development, the new data acquisition software under MS Windows operating system is also developed to drive a beam stopper in X-Y directions as well as to read the equipment status such as position of the collimators and PSD, to acquire neutron counts on monitor and PSD detectors, and also to manage 12 samples position automatically. A timer object which is set in one second to read the equipment status via serial port of the computer (RS232C), and general purpose interface board (GPIB) for reading the total counts of each pixel of the PSD from histogram memory was used in this new software. The experiment result displayed in real time on the main window, and the data is saved in the special format for further data reduction and analysis. The new software has been implemented and performed for experiment using a preset count or preset time mode for absolute scattering intensity method.« less
NASA Astrophysics Data System (ADS)
Bharoto, Suparno, Nadi; Putra, Edy Giri Rachman
2015-04-01
In 2005, the main computer for data acquisition and control system of Small-angle Neutron Scattering (SANS) BATAN Spectrometer (SMARTer) was replaced since it halted to operate the spectrometer. According to this replacement, the new software for data acquisition and control system has been developed in-house. Visual Basic programming language is used in developing the software. In the last two years, many developments have been made both in the hardware and also the software to conduct the experiment is more effective and efficient. Lately, the previous motor controller card (ISA Card) was replaced with the programmable motor controller card (PCI Card) for driving one motor of position sensitive detector (PSD), eight motors of four collimators, and six motors of six pinhole discs. This new control system software makes all motors can be moved simultaneously, then it reduces significantly the consuming time of setting up the instrument before running the experiment. Along with that development, the new data acquisition software under MS Windows operating system is also developed to drive a beam stopper in X-Y directions as well as to read the equipment status such as position of the collimators and PSD, to acquire neutron counts on monitor and PSD detectors, and also to manage 12 samples position automatically. A timer object which is set in one second to read the equipment status via serial port of the computer (RS232C), and general purpose interface board (GPIB) for reading the total counts of each pixel of the PSD from histogram memory was used in this new software. The experiment result displayed in real time on the main window, and the data is saved in the special format for further data reduction and analysis. The new software has been implemented and performed for experiment using a preset count or preset time mode for absolute scattering intensity method.
Hardware Timestamping for an Image Acquisition System Based on FlexRIO and IEEE 1588 v2 Standard
NASA Astrophysics Data System (ADS)
Esquembri, S.; Sanz, D.; Barrera, E.; Ruiz, M.; Bustos, A.; Vega, J.; Castro, R.
2016-02-01
Current fusion devices usually implement distributed acquisition systems for the multiple diagnostics of their experiments. However, each diagnostic is composed by hundreds or even thousands of signals, including images from the vessel interior. These signals and images must be correctly timestamped, because all the information will be analyzed to identify plasma behavior using temporal correlations. For acquisition devices without synchronization mechanisms the timestamp is given by another device with timing capabilities when signaled by the first device. Later, each data should be related with its timestamp, usually via software. This critical action is unfeasible for software applications when sampling rates are high. In order to solve this problem this paper presents the implementation of an image acquisition system with real-time hardware timestamping mechanism. This is synchronized with a master clock using the IEEE 1588 v2 Precision Time Protocol (PTP). Synchronization, image acquisition and processing, and timestamping mechanisms are implemented using Field Programmable Gate Array (FPGA) and a timing card -PTP v2 synchronized. The system has been validated using a camera simulator streaming videos from fusion databases. The developed architecture is fully compatible with ITER Fast Controllers and has been integrated with EPICS to control and monitor the whole system.
Kember, Sally A; Hansen, Vibeke N; Fast, Martin F; Nill, Simeon; McDonald, Fiona; Ahmed, Merina; Thomas, Karen; McNair, Helen A
2016-07-01
To evaluate three image acquisition presets for four-dimensional cone beam CT (CBCT) to identify an optimal preset for lung tumour image quality while minimizing dose and acquisition time. Nine patients undergoing radical conventionally fractionated radiotherapy for lung cancer had verification CBCTs acquired using three presets: Preset 1 on Day 1 (11 mGy dose, 240 s acquisition time), Preset 2 on Day 2 (9 mGy dose, 133 s acquisition time) and Preset 3 on Day 3 (9 mGy dose, 67 s acquisition time). The clarity of the tumour and other thoracic structures, and the acceptability of the match, were retrospectively graded by visual grading analysis (VGA). Logistic regression was used to identify the most appropriate preset and any factors that might influence the result. Presets 1 and 2 met a clinical requirement of 75% of structures to be rated "Clear" or above and 75% of matches to be rated "Acceptable" or above. Clarity is significantly affected by preset, patient, observer and structure. Match acceptability is significantly affected by preset. The application of VGA in this initial study enabled a provisional selection of an optimal preset (Preset 2) to be made. This was the first application of VGA to the investigation of presets for CBCT.
Lüdemann, Lutz; Nafz, Benno; Elsner, Franz; Grosse-Siestrup, Christian; Meissler, Michael; Kaufels, Nicola; Rehbein, Hagen; Persson, Pontus B; Michaely, Henrik J; Lengsfeld, Philipp; Voth, Matthias; Gutberlet, Matthias
2009-03-01
To evaluate for the first time in an animal model the possibility of absolute regional quantification of renal medullary and cortical perfusion by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using a blood pool contrast agent. A total of 18 adult female pigs (age, 16-22 weeks; body weight, 45-65 kg; no dietary restrictions) were investigated by DCE-MRI. Absolute renal blood flow (RBF) measured by an ultrasound transit time flow probe around the renal vein was used as the standard of reference. An inflatable stainless cuff placed around the renal artery near its origin from the abdominal aorta was used to reduce RBF to 60%, 40%, and 20% of the baseline flow. The last measurement was performed with the cuff fully reopened. Absolute RBF values during these 4 perfusion states were compared with the results of DCE-MRI performed on a 1.5-T scanner with an 8-channel phased-array surface coil. All scans were acquired in breath-hold technique in the coronal plane using a field of view of 460 mm.Each dynamic scan commenced with a set of five 3D T1-weighted gradient echo sequences with different flip angles (alpha = 2 degrees, 5 degrees, 10 degrees, 20 degrees, 30 degrees): TE, 0.88 milliseconds; TR, 2.65 milliseconds; slice thickness, 8.8 mm for 4 slices; acquisition matrix, 128 x 128; and acquisitions, 4. These data served to calculate 3D intrinsic longitudinal relaxation rate maps (R10) and magnetization (M0). Immediately after these images, the dynamic 3D T1-weighted gradient echo images were acquired with the same parameters and a constant alpha = 30 degrees, half Fourier, 1 acquisition, 64 frames, a time interval of 1.65 seconds between each frame, and a total duration of 105.6. Three milliliters of an albumin-binding blood pool contrast agent (0.25 mmol/mL gadofosveset trisodium, Vasovist, Bayer Schering Pharma AG, Berlin, Germany) was injected at a rate of 3 mL/s. Perfusion was calculated using the arterial input function from the aorta, which was extracted from the dynamic relaxation rate change maps and perfusion images were calculated on a voxel-by-voxel basis using a singular value decomposition. In 11 pigs, 4 different perfusion states were investigated sequentially. The reduced kidney perfusion measured by ultrasound highly correlated with total renal blood flow determined by DCE-MRI, P < 0.001. The correlation coefficient between both measurements was 0.843. Regional cortical and medullary renal flow was also highly correlated (r = 0.77/0.78, P < 0.001) with the degree of flow reduction. Perfusion values smaller than 50 mL/min/100 cm were overestimated by MRI, high perfusion values slightly underestimated. DCE-MRI using a blood pool contrast agent allows absolute quantification of total kidney perfusion as well as separate determination of cortical and medullary flow. The results show that our technique has sufficient accuracy and reproducibility to be transferred to the clinical setting.
48 CFR 552.270-18 - Default in Delivery-Time Extensions.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 4 2014-10-01 2014-10-01 false Default in Delivery-Time Extensions. 552.270-18 Section 552.270-18 Federal Acquisition Regulations System GENERAL SERVICES... leases, in excess of the aggregate rent and estimated real estate tax and operating cost adjustments for...
48 CFR 552.270-18 - Default in Delivery-Time Extensions.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 4 2012-10-01 2012-10-01 false Default in Delivery-Time Extensions. 552.270-18 Section 552.270-18 Federal Acquisition Regulations System GENERAL SERVICES... leases, in excess of the aggregate rent and estimated real estate tax and operating cost adjustments for...
48 CFR 552.270-18 - Default in Delivery-Time Extensions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 4 2011-10-01 2011-10-01 false Default in Delivery-Time Extensions. 552.270-18 Section 552.270-18 Federal Acquisition Regulations System GENERAL SERVICES... leases, in excess of the aggregate rent and estimated real estate tax and operating cost adjustments for...
48 CFR 552.270-18 - Default in Delivery-Time Extensions.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 4 2013-10-01 2013-10-01 false Default in Delivery-Time Extensions. 552.270-18 Section 552.270-18 Federal Acquisition Regulations System GENERAL SERVICES... leases, in excess of the aggregate rent and estimated real estate tax and operating cost adjustments for...
26 CFR 1.269-5 - Time of acquisition of control.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 1.269-5 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Items Not Deductible § 1.269-5 Time of acquisition of control. (a) In... whether the creditors acquired control of Corporation L no earlier with the principal purpose of evasion...
48 CFR 2052.215-72 - Timely receipt of proposals.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Timely receipt of proposals. 2052.215-72 Section 2052.215-72 Federal Acquisition Regulations System NUCLEAR REGULATORY...-carried deliveries. The NRC is a secure facility with perimeter access-control and NRC personnel are only...
48 CFR 2052.215-72 - Timely receipt of proposals.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Timely receipt of proposals. 2052.215-72 Section 2052.215-72 Federal Acquisition Regulations System NUCLEAR REGULATORY...-carried deliveries. The NRC is a secure facility with perimeter access-control and NRC personnel are only...
48 CFR 2052.214-73 - Timely receipt of bids.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false Timely receipt of bids. 2052.214-73 Section 2052.214-73 Federal Acquisition Regulations System NUCLEAR REGULATORY COMMISSION... is a secure facility with perimeter access-control and NRC personnel are only available to receive...
48 CFR 2052.215-72 - Timely receipt of proposals.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Timely receipt of proposals. 2052.215-72 Section 2052.215-72 Federal Acquisition Regulations System NUCLEAR REGULATORY...-carried deliveries. The NRC is a secure facility with perimeter access-control and NRC personnel are only...
48 CFR 2052.215-72 - Timely receipt of proposals.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false Timely receipt of proposals. 2052.215-72 Section 2052.215-72 Federal Acquisition Regulations System NUCLEAR REGULATORY...-carried deliveries. The NRC is a secure facility with perimeter access-control and NRC personnel are only...
48 CFR 2052.214-73 - Timely receipt of bids.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Timely receipt of bids. 2052.214-73 Section 2052.214-73 Federal Acquisition Regulations System NUCLEAR REGULATORY COMMISSION... is a secure facility with perimeter access-control and NRC personnel are only available to receive...
48 CFR 2052.214-73 - Timely receipt of bids.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Timely receipt of bids. 2052.214-73 Section 2052.214-73 Federal Acquisition Regulations System NUCLEAR REGULATORY COMMISSION... is a secure facility with perimeter access-control and NRC personnel are only available to receive...
48 CFR 2052.214-73 - Timely receipt of bids.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Timely receipt of bids. 2052.214-73 Section 2052.214-73 Federal Acquisition Regulations System NUCLEAR REGULATORY COMMISSION... is a secure facility with perimeter access-control and NRC personnel are only available to receive...
48 CFR 552.270-18 - Default in Delivery-Time Extensions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Default in Delivery-Time Extensions. 552.270-18 Section 552.270-18 Federal Acquisition Regulations System GENERAL SERVICES... leases, in excess of the aggregate rent and estimated real estate tax and operating cost adjustments for...
2008-06-01
provide the coverage. To enable weak GPS signal acquisition , one known technique at the receiver end is to extend the signal integration time...Han, “Block Accumulating Coherent Integration Over Extended Interval (BACIX) for Weak GPS Signal Acquisition ,” Proc. of ION-GNSS’06, Ft. Worth, TX...AFRL-RY-WP-TP-2008-1158 POST-CORRELATION SEMI-COHERENT INTEGRATION FOR HIGH-DYNAMIC AND WEAK GPS SIGNAL ACQUISITION (PREPRINT) Chun Yang
Optimizing Basic French Skills Utilizing Multiple Teaching Techniques.
ERIC Educational Resources Information Center
Skala, Carol
This action research project examined the impact of foreign language teaching techniques on the language acquisition and retention of 19 secondary level French I students, focusing on student perceptions of the effectiveness and ease of four teaching techniques: total physical response, total physical response storytelling, literature approach,…
Report on the Total System Computer Program for Medical Libraries.
ERIC Educational Resources Information Center
Divett, Robert T.; Jones, W. Wayne
The objective of this project was to develop an integrated computer program for the total operations of a medical library including acquisitions, cataloging, circulation, reference, a computer catalog, serials controls, and current awareness services. The report describes two systems approaches: the batch system and the terminal system. The batch…
Rethinking Twenty-First Century Acquisition: Emerging Trends for Efficiency Ends
1997-01-01
improve the quality of their services. However, dispari- ties in current accounting methods and rules between the two sectors make evalu- ating costs ...are facilitated by the grow- ing use of ABC methods in the account - ing community. These methods tie the to- tal costs of production or services more...Acquisition program man- agers can learn by studying recent devel- opments in the private sector accounting community. Knowledge of relevant total costs and
History of the KC-10A Aircraft Acquisition
1988-04-01
in other research reports or educational pursuits contingent upon the following stipulations: - Reproduction rights do not extend to any copyrighted...MAC, AFLC, and others) would create data for flight, maintenance, and technical data manuals, and evaluate human engineering factors. This testing...productio); ond deli.erme:; ra.. a fa:st rate and the acquisition program began to phase out.. The, total fleot gjrew to 52 aircraft, and del ivf , ics of th:ý
Cost Estimation of Naval Ship Acquisition.
1983-12-01
one a 9-sub- system model , the other a single total cost model . The models were developed using the linear least squares regression tech- nique with...to Linear Statistical Models , McGraw-Hill, 1961. 11. Helmer, F. T., Bibliography on Pricing Methodology and Cost Estimating, Dept. of Economics and...SUPPI.EMSaTARY NOTES IS. KWRo" (Cowaft. en tever aide of ..aesep M’ Idab~t 6 Week ONNa.) Cost estimation; Acquisition; Parametric cost estimate; linear
A versatile optical microscope for time-dependent single-molecule and single-particle spectroscopy
NASA Astrophysics Data System (ADS)
Li, Hao; Yang, Haw
2018-03-01
This work reports the design and implementation of a multi-function optical microscope for time-dependent spectroscopy on single molecules and single nanoparticles. It integrates the now-routine single-object measurements into one standalone platform so that no reconfiguration is needed when switching between different types of sample or spectroscopy modes. The illumination modes include evanescent field through total internal reflection, dark-field illumination, and epi-excitation onto a diffraction-limited spot suitable for confocal detection. The detection modes include spectrally resolved line imaging, wide-field imaging with dual-color capability, and two-color single-element photon-counting detection. The switch between different spectroscopy and data acquisition modes is fully automated and executed through computer programming. The capability of this microscope is demonstrated through selected proof-of-principle experiments.
Biomedical applications of a real-time terahertz color scanner
Schirmer, Markus; Fujio, Makoto; Minami, Masaaki; Miura, Jiro; Araki, Tsutomu; Yasui, Takeshi
2010-01-01
A real-time THz color scanner has the potential to further expand the application scope of THz spectral imaging based on its rapid image acquisition rate. We demonstrated three possible applications of a THz color scanner in the biomedical field: imaging of pharmaceutical tablets, human teeth, and human hair. The first application showed the scanner’s potential in total inspection for rapid quality control of pharmaceutical tablets moving on a conveyor belt. The second application demonstrated that the scanner can be used to identify a potential indicator for crystallinity of dental tissue. In the third application, the scanner was successfully used to visualize the drying process of wet hairs. These demonstrations indicated the high potential of the THz color scanner for practical applications in the biomedical field. PMID:21258472
A versatile optical microscope for time-dependent single-molecule and single-particle spectroscopy.
Li, Hao; Yang, Haw
2018-03-28
This work reports the design and implementation of a multi-function optical microscope for time-dependent spectroscopy on single molecules and single nanoparticles. It integrates the now-routine single-object measurements into one standalone platform so that no reconfiguration is needed when switching between different types of sample or spectroscopy modes. The illumination modes include evanescent field through total internal reflection, dark-field illumination, and epi-excitation onto a diffraction-limited spot suitable for confocal detection. The detection modes include spectrally resolved line imaging, wide-field imaging with dual-color capability, and two-color single-element photon-counting detection. The switch between different spectroscopy and data acquisition modes is fully automated and executed through computer programming. The capability of this microscope is demonstrated through selected proof-of-principle experiments.
Triaxial Probe Magnetic Data Analysis
NASA Technical Reports Server (NTRS)
Shultz, Kimberly; Whittlesey, Albert; Narvaez, Pablo
2007-01-01
The Triaxial Magnetic Moment Analysis software uses measured magnetic field test data to compute dipole and quadrupole moment information from a hardware element. It is used to support JPL projects needing magnetic control and an understanding of the spacecraft-generated magnetic fields. Evaluation of the magnetic moment of an object consists of three steps: acquisition, conditioning, and analysis. This version of existing software was extensively rewritten for easier data acquisition, data analysis, and report presentation, including immediate feedback to the test operator during data acquisition. While prior JPL computer codes provided the same data content, this program has a better graphic display including original data overlaid with reconstructed results to show goodness of fit accuracy and better appearance of the report graphic page. Data are acquired using three magnetometers and two rotations of the device under test. A clean acquisition user interface presents required numeric data and graphic summaries, and the analysis module yields the best fit (least squares) for the magnetic dipole and/or quadrupole moment of a device. The acquisition module allows the user to record multiple data sets, selecting the best data to analyze, and is repeated three times for each of the z-axial and y-axial rotations. In this update, the y-axial rotation starting position has been changed to an option, allowing either the x- or z-axis to point towards the magnetometer. The code has been rewritten to use three simultaneous axes of magnetic data (three probes), now using two "rotations" of the device under test rather than the previous three rotations, thus reducing handling activities on the device under test. The present version of the software gathers data in one-degree increments, which permits much better accuracy of the fit ted data than the coarser data acquisition of the prior software. The data-conditioning module provides a clean data set for the analysis module. For multiple measurements at a given degree, the first measurement is used. For omitted measurements, the missing field is estimated by linear interpolation between the two nearest measurements. The analysis module was rewritten for the dual rotation, triaxial probe measurement process and now has better moment estimation accuracy, based on the finer one degree of data acquisition resolution. The magnetic moments thus computed are used as an input to summarize the total spacecraft field.
Department of Defense Weapon System Acquisition Policy: A System Dynamics Model and Analysis.
1982-09-01
dimensionless) PRPRD = Perceived Pressure for R&D (dimensionless) PU - Programs in Progress (programs) RPRD - Raw Pressure for R&D (dimensionless) TDPP - Time...ECAP) TH9 Pressure Ra Pressure_.- for Acquisition ( TDPP ) TH25 4for Acquisition (DPFAO) TH22D (DPPFAO) TH21 US Intelligence \\ - 7 Delay Time / efense...DIBP, DPPFAQ. K) TH22 A CPPFAG.K=DLINF3(RPFAG.KTCPP) TH23 A CPFAQ.K=MAX (DIBPCPPFAQ.K) TH24 C TDPP =12 TH25 C TCPP-24 TH26 CPFAQ Congressional Pressure
NASA Astrophysics Data System (ADS)
Lippitz, Michael J.
1999-08-01
This paper proposes a framework for quantitatively balancing the costs, benefits, and risks of alternate upgrade strategies, with Department of Defense (DoD) acquisition of flat panel display as an example. A key issue in DoD Acquisition Reform is the rapid product turnover in commercial markets and the difficulties DoD has traditionally faced in adopting these advances in a timely manner. This paper aims to clarify when commercial technology represents 'best value' to DoD.
Data Acquisition and Real-Time Systems.
ERIC Educational Resources Information Center
Lawrence, D. E., Ed.; Fenwick, P. M., Ed.
The first group of papers starts with a tutorial paper which surveys the methods used in data acquisition systems. Other papers in this group describe: (1) some problems involved in the computer acquisition of high-speed randomly-occurring data and the protection of this data from accidental corruption, (2) an input/output bus to allow an IBM…
25 CFR 700.3 - Assurances with respect to acquisition and displacement.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 25 Indians 2 2010-04-01 2010-04-01 false Assurances with respect to acquisition and displacement... displacement. The Commission will not approve any programs or projects which may result in the acquisition of habitations and/or improvements, or in the displacement of any person, until such time as written assurances...
25 CFR 700.3 - Assurances with respect to acquisition and displacement.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 25 Indians 2 2011-04-01 2011-04-01 false Assurances with respect to acquisition and displacement... displacement. The Commission will not approve any programs or projects which may result in the acquisition of habitations and/or improvements, or in the displacement of any person, until such time as written assurances...
25 CFR 700.3 - Assurances with respect to acquisition and displacement.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 25 Indians 2 2012-04-01 2012-04-01 false Assurances with respect to acquisition and displacement... displacement. The Commission will not approve any programs or projects which may result in the acquisition of habitations and/or improvements, or in the displacement of any person, until such time as written assurances...
25 CFR 700.3 - Assurances with respect to acquisition and displacement.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false Assurances with respect to acquisition and displacement... displacement. The Commission will not approve any programs or projects which may result in the acquisition of habitations and/or improvements, or in the displacement of any person, until such time as written assurances...
25 CFR 700.3 - Assurances with respect to acquisition and displacement.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false Assurances with respect to acquisition and displacement... displacement. The Commission will not approve any programs or projects which may result in the acquisition of habitations and/or improvements, or in the displacement of any person, until such time as written assurances...
Samanipour, Saer; Reid, Malcolm J; Bæk, Kine; Thomas, Kevin V
2018-04-17
Nontarget analysis is considered one of the most comprehensive tools for the identification of unknown compounds in a complex sample analyzed via liquid chromatography coupled to high-resolution mass spectrometry (LC-HRMS). Due to the complexity of the data generated via LC-HRMS, the data-dependent acquisition mode, which produces the MS 2 spectra of a limited number of the precursor ions, has been one of the most common approaches used during nontarget screening. However, data-independent acquisition mode produces highly complex spectra that require proper deconvolution and library search algorithms. We have developed a deconvolution algorithm and a universal library search algorithm (ULSA) for the analysis of complex spectra generated via data-independent acquisition. These algorithms were validated and tested using both semisynthetic and real environmental data. A total of 6000 randomly selected spectra from MassBank were introduced across the total ion chromatograms of 15 sludge extracts at three levels of background complexity for the validation of the algorithms via semisynthetic data. The deconvolution algorithm successfully extracted more than 60% of the added ions in the analytical signal for 95% of processed spectra (i.e., 3 complexity levels multiplied by 6000 spectra). The ULSA ranked the correct spectra among the top three for more than 95% of cases. We further tested the algorithms with 5 wastewater effluent extracts for 59 artificial unknown analytes (i.e., their presence or absence was confirmed via target analysis). These algorithms did not produce any cases of false identifications while correctly identifying ∼70% of the total inquiries. The implications, capabilities, and the limitations of both algorithms are further discussed.
Adaptive weld control for high-integrity welding applications
NASA Technical Reports Server (NTRS)
Powell, Bradley W.
1993-01-01
An advanced adaptive control weld system for high-integrity welding applications is presented. The system consists of a state-of-the-art weld control subsystem, motion control subsystem, and sensor subsystem which closes the loop on the process. The adaptive control subsystem (ACS), which is required to totally close the loop on weld process control, consists of a multiprocessor system, data acquisition hardware, and three welding sensors which provide measurements from all areas around the torch in real time. The ACS acquires all 'measurables' and feeds offset trims back into the weld control and motion control subsystems to modify the 'controllables' in order to maintain a previously defined weld quality.
Doss, F. W.; Flippo, K. A.; Capelli, D.; ...
2016-05-26
Updates to the Los Alamos laser-driven high-energy-density Shock/Shear mixing- layer experiment are reported, which have collectively increased the platform's shot and data acquisition rates. Also, the strategies employed have included a move from two-strip to four-strip imagers (allowing four times to be recorded per shot instead of two), the implementation of physics-informed rules of engagements allowing for the maximum flexibility in a shot's total energy and symmetry performance, and by splitting the laser's main drive pulse from a monolithic single pulse equal to all beams into a triply-segmented pulse which minimizes optics damage.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doss, F. W.; Flippo, K. A.; Capelli, D.
Updates to the Los Alamos laser-driven high-energy-density Shock/Shear mixing- layer experiment are reported, which have collectively increased the platform's shot and data acquisition rates. Also, the strategies employed have included a move from two-strip to four-strip imagers (allowing four times to be recorded per shot instead of two), the implementation of physics-informed rules of engagements allowing for the maximum flexibility in a shot's total energy and symmetry performance, and by splitting the laser's main drive pulse from a monolithic single pulse equal to all beams into a triply-segmented pulse which minimizes optics damage.
A Collection of Technical Papers
NASA Technical Reports Server (NTRS)
1995-01-01
Papers presented at the 6th Space Logistics Symposium covered such areas as: The International Space Station; The Hubble Space Telescope; Launch site computer simulation; Integrated logistics support; The Baikonur Cosmodrome; Probabalistic tools for high confidence repair; A simple space station rescue vehicle; Integrated Traffic Model for the International Space Station; Packaging the maintenance shop; Leading edge software support; Storage information management system; Consolidated maintenance inventory logistics planning; Operation concepts for a single stage to orbit vehicle; Mission architecture for human lunar exploration; Logistics of a lunar based solar power satellite scenario; Just in time in space; NASA acquisitions/logistics; Effective transition management; Shuttle logistics; and Revitalized space operations through total quality control management.
Sharif, Behzad; Bresler, Yoram
2013-01-01
Patient-Adaptive Reconstruction and Acquisition Dynamic Imaging with Sensitivity Encoding (PARADISE) is a dynamic MR imaging scheme that optimally combines parallel imaging and model-based adaptive acquisition. In this work, we propose the application of PARADISE to real-time cardiac MRI. We introduce a physiologically improved version of a realistic four-dimensional cardiac-torso (NCAT) phantom, which incorporates natural beat-to-beat heart rate and motion variations. Cardiac cine imaging using PARADISE is simulated and its performance is analyzed by virtue of the improved phantom. Results verify the effectiveness of PARADISE for high resolution un-gated real-time cardiac MRI and its superiority over conventional acquisition methods. PMID:24398475
Functional analysis of an feoB mutant in Clostridium perfringens strain 13.
Awad, Milena M; Cheung, Jackie K; Tan, Joanne E; McEwan, Alastair G; Lyras, Dena; Rood, Julian I
2016-10-01
Bacterial pathogens have adopted numerous mechanisms for acquiring iron from host proteins during an infection, including the direct acquisition of ferric iron from heme-associated proteins or from iron-scavenging siderophores. Ferric iron then is transported into the cytosol, where it can be utilized by the bacterial pathogen. Under anaerobic conditions bacteria can also transport ferrous iron using the transmembrane complex FeoAB, but little is known about iron transport systems in anaerobic bacteria such as the pathogenic clostridia. In this study we sought to characterize the iron acquisition process in Clostridium perfringens. Bioinformatic analysis of the Clostridium perfringens strain 13 genome sequence revealed that it has seven potential iron acquisition systems: three siderophore-mediated systems, one ferric citrate uptake system, two heme-associated acquisition systems and one ferrous iron uptake system (FeoAB). The relative level of expression of these systems was determined using quantitative real-time RT-PCR assays that were specific for one gene from each system. Each of these genes was expressed, with the feoAB genes generating the most abundant iron-uptake related transcripts. To further examine the role of this system in the growth of C. perfringens, insertional inactivation was used to isolate a chromosomal feoB mutant. Growth of this mutant in the presence and absence of iron revealed that it had altered growth properties and a markedly reduced total iron and manganese content compared to the wild type; effects that were reversed upon complementation with the wild-type feoB gene. These studies suggest that under anaerobic conditions FeoB is the major protein required for the uptake of iron into the cell and that it may play an important role in the pathogenesis of C. perfringens infections. Copyright © 2016 Elsevier Ltd. All rights reserved.
Debes, Anders J; Aggarwal, Rajesh; Balasundaram, Indran; Jacobsen, Morten B
2010-06-01
This study aimed to assess the transferability of basic laparoscopic skills between a virtual reality simulator (MIST-VR) and a video trainer box (D-Box). Forty-six medical students were randomized into 2 groups, training on MIST-VR or D-Box. After training with one modality, a crossover assessment on the other was performed. When tested on MIST-VR, the MIST-VR group showed significantly shorter time (90.3 seconds vs 188.6 seconds, P <.001), better economy of movements (4.40 vs 7.50, P <.001), and lower score (224.7 vs 527.0, P <.001). However, when assessed on the D-Box, there was no difference between the groups for time (402.0 seconds vs 325.6 seconds, P = .152), total hand movements (THC) (289 vs 262, P = .792), or total path length (TPL) (34.9 m vs 34.6 m, P = .388). Both simulators provide significant improvement in performance. Our results indicate that skills learned on the MIST-VR are transferable to the D-Box, but the opposite cannot be demonstrated. Copyright 2010 Elsevier Inc. All rights reserved.
Tan, Huan; Hoge, W. Scott; Hamilton, Craig A.; Günther, Matthias; Kraft, Robert A.
2014-01-01
Arterial spin labeling (ASL) is a non-invasive technique that can quantitatively measure cerebral blood flow (CBF). While traditionally ASL employs 2D EPI or spiral acquisition trajectories, single-shot 3D GRASE is gaining popularity in ASL due to inherent SNR advantage and spatial coverage. However, a major limitation of 3D GRASE is through-plane blurring caused by T2 decay. A novel technique combining 3D GRASE and a PROPELLER trajectory (3DGP) is presented to minimize through-plane blurring without sacrificing perfusion sensitivity or increasing total scan time. Full brain perfusion images were acquired at a 3×3×5mm3 nominal voxel size with Q2TIPS-FAIR as the ASL preparation sequence. Data from 5 healthy subjects was acquired on a GE 1.5T scanner in less than 4 minutes per subject. While showing good agreement in CBF quantification with 3D GRASE, 3DGP demonstrated reduced through-plane blurring, improved anatomical details, high repeatability and robustness against motion, making it suitable for routine clinical use. PMID:21254211
A programmable light engine for quantitative single molecule TIRF and HILO imaging.
van 't Hoff, Marcel; de Sars, Vincent; Oheim, Martin
2008-10-27
We report on a simple yet powerful implementation of objective-type total internal reflection fluorescence (TIRF) and highly inclined and laminated optical sheet (HILO, a type of dark-field) illumination. Instead of focusing the illuminating laser beam to a single spot close to the edge of the microscope objective, we are scanning during the acquisition of a fluorescence image the focused spot in a circular orbit, thereby illuminating the sample from various directions. We measure parameters relevant for quantitative image analysis during fluorescence image acquisition by capturing an image of the excitation light distribution in an equivalent objective backfocal plane (BFP). Operating at scan rates above 1 MHz, our programmable light engine allows directional averaging by circular spinning the spot even for sub-millisecond exposure times. We show that restoring the symmetry of TIRF/HILO illumination reduces scattering and produces an evenly lit field-of-view that affords on-line analysis of evanescnt-field excited fluorescence without pre-processing. Utilizing crossed acousto-optical deflectors, our device generates arbitrary intensity profiles in BFP, permitting variable-angle, multi-color illumination, or objective lenses to be rapidly exchanged.
Lai, Chang-Jiang-Sheng; Tan, Ting; Zeng, Su-Ling; Qi, Lian-Wen; Liu, Xin-Guang; Dong, Xin; Li, Ping; Liu, E-Hu
2015-05-10
The aim of this study was to develop a convenient method without pretreatments for nontarget discovery of interested compounds. The segment and exposure strategy, coupled with two mass spectrometer data acquisition methods was firstly proposed for screening the saponins in extract of Panax notoginseng (Sanqi) via high-performance liquid chromatography tandem quadrupole time-of-flight mass spectrometry (HPLC-QTOF/MS). By gradually removing certain major or moderate interference compounds, the developed segment and exposure strategy could significantly improve the detection efficiency for trace compounds. Moreover, the newly developed five-point screening approach based on a modified mass defect filter strategy and the visual isotopic ion technique was verified to be efficient and reliable in picking out the interested precursor ions. In total, 234 ginsenosides including 67 potential new ones were characterized or tentatively identified from the extract of Sanqi. Particularly, some unusual compounds containing the branched glycosyl group or new substituted acyl groups were firstly reported. The proposed integrated strategy held a strong promise for analyses of the complex mixtures. Copyright © 2015 Elsevier B.V. All rights reserved.
Memory consolidation and contextual interference effects with computer games.
Shewokis, Patricia A
2003-10-01
Some investigators of the contextual interference effect contend that there is a direct relation between the amount of practice and the contextual interference effect based on the prediction that the improvement in learning tasks in a random practice schedule, compared to a blocked practice schedule, increases in magnitude as the amount of practice during acquisition on the tasks increases. Research using computer games in contextual interference studies has yielded a large effect (f = .50) with a random practice schedule advantage during transfer. These investigations had a total of 36 and 72 acquisition trials, respectively. The present study tested this prediction by having 72 college students, who were randomly assigned to a blocked or random practice schedule, practice 102 trials of three computer-game tasks across three days. After a 24-hr. interval, 6 retention and 5 transfer trials were performed. Dependent variables were time to complete an event in seconds and number of errors. No significant differences were found for retention and transfer. These results are discussed in terms of how the amount of practice, task-related factors, and memory consolidation mediate the contextual interference effect.
NASA Astrophysics Data System (ADS)
Gong, Xiangbo; Feng, Fei; Jiao, Xuming; Wang, Shengchao
2017-10-01
Simultaneous seismic source separation, also known as deblending, is an essential process for blended acquisition. With the assumption that the blending noise is coherent in the common shot domain but is incoherent in other domains, traditional deblending methods are commonly performed in the common receiver, common midpoint or common offset domain. In this paper, we propose an improved apex-shifted hyperbolic radon transform (ASHRT) to deblend directly in the common shot domain. A time-axis stretch strategy named Stolt-stretch is introduced to overcome the limitation of the constant velocity assumption of Stolt-based operators. To improve the sparsity in the transform domain, a total variation (TV) norm inversion is implemented to enhance the energy convergence in the radon panel. Because of highly efficient Stolt migration and the demigration operator in the frequency-wavenumber domain, as well as the flexible geometry condition of the source-receiver, this approach is quite suitable for quality control (QC) during streamer acquisition. The synthetic and field examples demonstrate that our proposition is robust and efficient.
Auranen, Kari; Syrjänen, Ritva; Leino, Tuija; Kilpi, Terhi
2016-01-01
For considering vaccine-prevention of pneumococcal acute otitis media (PncAOM), relationships between pneumococcal carriage, respiratory infection and PncAOM need to be understood. We analyzed nasopharyngeal samples collected from 329 unvaccinated Finnish children aged 2-24 months at scheduled visits and at visits during respiratory infection in 1994-97. We assessed temporal associations of respiratory infection with pneumococcal acquisition and whether PncAOM hazard depends on the relative timing of acquisition and the infection onset. The data comprised 607 person-years of risk-time for acquisition, 245 person-months of concurrent respiratory infection and carriage, and 119 episodes of PncAOM. The acquisition hazard was 3-fold in the month preceding respiratory sickness (hazard ratio, HR 3.5, 90% credible interval CI 2.9, 4.1) as compared to acquisition in healthy children. Moreover, the PncAOM hazard was markedly higher (HR 3.7, 90% CI 2.4, 5.3) during the first month of carriage acquired around the acute phase of respiratory infection (between 1 month before and 1 week after the sickness onset), as compared to carriage acquired later during sickness. The high proportion (76%) of PncAOM events occurring within 1 month of acquisition was due to frequent acquisition being associated with respiratory infection as well as the susceptibility of such acquisition to cause otitis media.
NASA Astrophysics Data System (ADS)
Gopinath, T.; Veglia, Gianluigi
2016-06-01
Conventional multidimensional magic angle spinning (MAS) solid-state NMR (ssNMR) experiments detect the signal arising from the decay of a single coherence transfer pathway (FID), resulting in one spectrum per acquisition time. Recently, we introduced two new strategies, namely DUMAS (DUal acquisition Magic Angle Spinning) and MEIOSIS (Multiple ExperIments via Orphan SpIn operatorS), that enable the simultaneous acquisitions of multidimensional ssNMR experiments using multiple coherence transfer pathways. Here, we combined the main elements of DUMAS and MEIOSIS to harness both orphan spin operators and residual polarization and increase the number of simultaneous acquisitions. We show that it is possible to acquire up to eight two-dimensional experiments using four acquisition periods per each scan. This new suite of pulse sequences, called MAeSTOSO for Multiple Acquisitions via Sequential Transfer of Orphan Spin pOlarization, relies on residual polarization of both 13C and 15N pathways and combines low- and high-sensitivity experiments into a single pulse sequence using one receiver and commercial ssNMR probes. The acquisition of multiple experiments does not affect the sensitivity of the main experiment; rather it recovers the lost coherences that are discarded, resulting in a significant gain in experimental time. Both merits and limitations of this approach are discussed.
RTSPM: real-time Linux control software for scanning probe microscopy.
Chandrasekhar, V; Mehta, M M
2013-01-01
Real time computer control is an essential feature of scanning probe microscopes, which have become important tools for the characterization and investigation of nanometer scale samples. Most commercial (and some open-source) scanning probe data acquisition software uses digital signal processors to handle the real time data processing and control, which adds to the expense and complexity of the control software. We describe here scan control software that uses a single computer and a data acquisition card to acquire scan data. The computer runs an open-source real time Linux kernel, which permits fast acquisition and control while maintaining a responsive graphical user interface. Images from a simulated tuning-fork based microscope as well as a standard topographical sample are also presented, showing some of the capabilities of the software.
NASA Astrophysics Data System (ADS)
Caro Cuenca, Miguel; Esfahany, Sami Samiei; Hanssen, Ramon F.
2010-12-01
Persistent scatterer Radar Interferometry (PSI) can provide with a wealth of information on surface motion. These methods overcome the major limitations of the antecessor technique, interferometric SAR (InSAR), such as atmospheric disturbances, by detecting the scatterers which are slightly affected by noise. The time span that surface deformation processes are observed is limited by the satellite lifetime, which is usually less than 10 years. However most of deformation phenomena last longer. In order to fully monitor and comprehend the observed signal, acquisitions from different sensors can be merged. This is a complex task for one main reason. PSI methods provide with estimations that are relative in time to one of the acquisitions which is referred to as master or reference image. Therefore, time series acquired by different sensors will have different reference images and cannot be directly compared or joint unless they are set to the same time reference system. In global terms, the operation of translating from one to another reference systems consist of calculating a vertical offset, which is the total deformation that occurs between the two master times. To estimate this offset, different strategies can be applied, for example, using additional data such as leveling or GPS measurements. In this contribution we propose to use a least squares to merge PSI time series without any ancillary information. This method treats the time series individually, i.e. per PS, and requires some knowledge of the deformation signal, for example, if a polynomial would fairly describe the expected behavior. To test the proposed approach, we applied it to the southern Netherlands, where the surface is affected by ground water processes in abandoned mines. The time series were obtained after processing images provided by ERS1/2 and Envisat. The results were validated using in-situ water measurements, which show very high correlation with deformation time series.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whitney, Richard; Berger, Matthew; Tonasket, Patrick
2006-12-01
The Colville Confederated Tribes Wildlife Mitigation Project is protecting lands as partial mitigation for hydropower's share of the wildlife losses resulting from Chief Joseph and Grand Coulee Dams. The Mitigation Project protects and manages 54,606 acres for the biological requirements of managed wildlife species that are important to the Colville Tribes. With the inclusion of 2006 acquisitions, the Colville Tribes have acquired approximately 32,018 habitat units (HUs) towards a total 35,819 HUs lost from original inundation due to hydropower development. This annual report for 2006 briefly describes that four priority land acquisitions that were considered for enrollment into the Colvillemore » Tribes Mitigation Project during the 2006 contract period.« less
Green Acquisitions And Lifecycle Management Of Industrial Products In The Circular Economy
NASA Astrophysics Data System (ADS)
Popa, Vasile N.; Popa, Luminita I.
2016-11-01
The article addresses the issue of green acquisitions which occur within an industrial company focused on reducing inputs while maintaining output (substitution and efficiency). These processes characterize a circular economy oriented on resource efficiency (costs saved by reducing purchasing inputs). In our article, we focus on the industrial procurement practice which can help businesses save money and materials. Besides the possibility to negotiate prices, buyers can influence suppliers to offer products and services in an efficient manner in terms of green resources. The life cycle of industrial products is used to demonstrate the environmental advantages and disadvantages of various options for acquisitions and initiatives to totally reuse them.
NASA Astrophysics Data System (ADS)
Zhao, Shuangle; Zhang, Xueyi; Sun, Shengli; Wang, Xudong
2017-08-01
TI C2000 series digital signal process (DSP) chip has been widely used in electrical engineering, measurement and control, communications and other professional fields, DSP TMS320F28035 is one of the most representative of a kind. When using the DSP program, need data acquisition and data processing, and if the use of common mode C or assembly language programming, the program sequence, analogue-to-digital (AD) converter cannot be real-time acquisition, often missing a lot of data. The control low accelerator (CLA) processor can run in parallel with the main central processing unit (CPU), and the frequency is consistent with the main CPU, and has the function of floating point operations. Therefore, the CLA coprocessor is used in the program, and the CLA kernel is responsible for data processing. The main CPU is responsible for the AD conversion. The advantage of this method is to reduce the time of data processing and realize the real-time performance of data acquisition.
The status of the QUIJOTE multi-frequency instrument
NASA Astrophysics Data System (ADS)
Hoyland, R. J.; Aguiar-González, M.; Aja, B.; Ariño, J.; Artal, E.; Barreiro, R. B.; Blackhurst, E. J.; Cagigas, J.; Cano de Diego, J. L.; Casas, F. J.; Davis, R. J.; Dickinson, C.; Arriaga, B. E.; Fernandez-Cobos, R.; de la Fuente, L.; Génova-Santos, R.; Gómez, A.; Gomez, C.; Gómez-Reñasco, F.; Grainge, K.; Harper, S.; Herran, D.; Herreros, J. M.; Herrera, G. A.; Hobson, M. P.; Lasenby, A. N.; Lopez-Caniego, M.; López-Caraballo, C.; Maffei, B.; Martinez-Gonzalez, E.; McCulloch, M.; Melhuish, S.; Mediavilla, A.; Murga, G.; Ortiz, D.; Piccirillo, L.; Pisano, G.; Rebolo-López, R.; Rubiño-Martin, J. A.; Ruiz, J. Luis; Sanchez de la Rosa, V.; Sanquirce, R.; Vega-Moreno, A.; Vielva, P.; Viera-Curbelo, T.; Villa, E.; Vizcargüenaga, A.; Watson, R. A.
2012-09-01
The QUIJOTE-CMB project has been described in previous publications. Here we present the current status of the QUIJOTE multi-frequency instrument (MFI) with five separate polarimeters (providing 5 independent sky pixels): two which operate at 10-14 GHz, two which operate at 16-20 GHz, and a central polarimeter at 30 GHz. The optical arrangement includes 5 conical corrugated feedhorns staring into a dual reflector crossed-draconian system, which provides optimal cross-polarization properties (designed to be < -35 dB) and symmetric beams. Each horn feeds a novel cryogenic on-axis rotating polar modulator which can rotate at a speed of up to 1 Hz. The science driver for this first instrument is the characterization of the galactic emission. The polarimeters use the polar modulator to derive linear polar parameters Q, U and I and switch out various systematics. The detection system provides optimum sensitivity through 2 correlated and 2 total power channels. The system is calibrated using bright polarized celestial sources and through a secondary calibration source and antenna. The acquisition system, telescope control and housekeeping are all linked through a real-time gigabit Ethernet network. All communication, power and helium gas are passed through a central rotary joint. The time stamp is synchronized to a GPS time signal. The acquisition software is based on PLCs written in Beckhoffs TwinCat and ethercat. The user interface is written in LABVIEW. The status of the QUIJOTE MFI will be presented including pre-commissioning results and laboratory testing.
Fast experiments for structure elucidation of small molecules: Hadamard NMR with multiple receivers.
Gierth, Peter; Codina, Anna; Schumann, Frank; Kovacs, Helena; Kupče, Ēriks
2015-11-01
We propose several significant improvements to the PANSY (Parallel NMR SpectroscopY) experiments-PANSY COSY and PANSY-TOCSY. The improved versions of these experiments provide sufficient spectral information for structure elucidation of small organic molecules from just two 2D experiments. The PANSY-TOCSY-Q experiment has been modified to allow for simultaneous acquisition of three different types of NMR spectra-1D C-13 of non-protonated carbon sites, 2D TOCSY and multiplicity edited 2D HETCOR. In addition the J-filtered 2D PANSY-gCOSY experiment records a 2D HH gCOSY spectrum in parallel with a (1) J-filtered HC long-range HETCOR spectrum as well as offers a simplified data processing. In addition to parallel acquisition, further time savings are feasible because of significantly smaller F1 spectral windows as compared to the indirect detection experiments. Use of cryoprobes and multiple receivers can significantly alleviate the sensitivity issues that are usually associated with the so called direct detection experiments. In cases where experiments are sampling limited rather than sensitivity limited further reduction of experiment time is achieved by using Hadamard encoding. In favorable cases the total recording time for the two PANSY experiments can be reduced to just 40 s. The proposed PANSY experiments provide sufficient information to allow the CMCse software package (Bruker) to solve structures of small organic molecules. Copyright © 2015 John Wiley & Sons, Ltd.
NASA Technical Reports Server (NTRS)
Pedings, Marc
2007-01-01
RT-Display is a MATLAB-based data acquisition environment designed to use a variety of commercial off-the-shelf (COTS) hardware to digitize analog signals to a standard data format usable by other post-acquisition data analysis tools. This software presents the acquired data in real time using a variety of signal-processing algorithms. The acquired data is stored in a standard Operator Interactive Signal Processing Software (OISPS) data-formatted file. RT-Display is primarily configured to use the Agilent VXI (or equivalent) data acquisition boards used in such systems as MIDDAS (Multi-channel Integrated Dynamic Data Acquisition System). The software is generalized and deployable in almost any testing environment, without limitations or proprietary configuration for a specific test program or project. With the Agilent hardware configured and in place, users can start the program and, in one step, immediately begin digitizing multiple channels of data. Once the acquisition is completed, data is converted into a common binary format that also can be translated to specific formats used by external analysis software, such as OISPS and PC-Signal (product of AI Signal Research Inc.). RT-Display at the time of this reporting was certified on Agilent hardware capable of acquisition up to 196,608 samples per second. Data signals are presented to the user on-screen simultaneously for 16 channels. Each channel can be viewed individually, with a maximum capability of 160 signal channels (depending on hardware configuration). Current signal presentations include: time data, fast Fourier transforms (FFT), and power spectral density plots (PSD). Additional processing algorithms can be easily incorporated into this environment.
Flight control systems development and flight test experience with the HiMAT research vehicles
NASA Technical Reports Server (NTRS)
Kempel, Robert W.; Earls, Michael R.
1988-01-01
Two highly maneuverable aircraft technology (HiMAT) remotely piloted vehicles were flown a total of 26 flights. These subscale vehicles were of advanced aerodynamic configuration with advanced technology concepts such as composite and metallic structures, digital integrated propulsion control, and ground (primary) and airborne (backup) relaxed static stability, digital fly-by-wire control systems. Extensive systems development, checkout, and flight qualification were required to conduct the flight test program. The design maneuver goal was to achieve a sustained 8-g turn at Mach 0.9 at an altitude of 25,000 feet. This goal was achieved, along with the acquisition of high-quality flight data at subsonic and supersonic Mach numbers. Control systems were modified in a variety of ways using the flight-determined aerodynamic characteristics. The HiMAT program was successfully completed with approximately 11 hours of total flight time.
NASA Astrophysics Data System (ADS)
Yang, C.; Zheng, W.; Zhang, M.; Yuan, T.; Zhuang, G.; Pan, Y.
2016-06-01
Measurement and control of the plasma in real-time are critical for advanced Tokamak operation. It requires high speed real-time data acquisition and processing. ITER has designed the Fast Plant System Controllers (FPSC) for these purposes. At J-TEXT Tokamak, a real-time data acquisition and processing framework has been designed and implemented using standard ITER FPSC technologies. The main hardware components of this framework are an Industrial Personal Computer (IPC) with a real-time system and FlexRIO devices based on FPGA. With FlexRIO devices, data can be processed by FPGA in real-time before they are passed to the CPU. The software elements are based on a real-time framework which runs under Red Hat Enterprise Linux MRG-R and uses Experimental Physics and Industrial Control System (EPICS) for monitoring and configuring. That makes the framework accord with ITER FPSC standard technology. With this framework, any kind of data acquisition and processing FlexRIO FPGA program can be configured with a FPSC. An application using the framework has been implemented for the polarimeter-interferometer diagnostic system on J-TEXT. The application is able to extract phase-shift information from the intermediate frequency signal produced by the polarimeter-interferometer diagnostic system and calculate plasma density profile in real-time. Different algorithms implementations on the FlexRIO FPGA are compared in the paper.
An intelligent data acquisition system for fluid mechanics research
NASA Technical Reports Server (NTRS)
Cantwell, E. R.; Zilliac, G.; Fukunishi, Y.
1989-01-01
This paper describes a novel data acquisition system for use with wind-tunnel probe-based measurements, which incorporates a degree of specific fluid dynamics knowledge into a simple expert system-like control program. The concept was developed with a rudimentary expert system coupled to a probe positioning mechanism operating in a small-scale research wind tunnel. The software consisted of two basic elements, a general-purpose data acquisition system and the rulebased control element to take and analyze data and supplying decisions as to where to measure, how many data points to take, and when to stop. The system was validated in an experiment involving a vortical flow field, showing that it was possible to increase the resolution of the experiment or, alternatively, reduce the total number of data points required, to achieve parity with the results of most conventional data acquisition approaches.
The quick acquisition technique for laser communication between LEO and GEO
NASA Astrophysics Data System (ADS)
Zhang, Li-zhong; Zhang, Rui-qin; Li, Yong-hao; Meng, Li-xin; Li, Xiao-ming
2013-08-01
The sight-axis alignment can be accomplished by the quick acquisition operation between two laser communication terminals, which is the premise of establishing a free-space optical communication link. Especially for the laser communication links of LEO (Low Earth Orbit)-Ground and LEO-GEO (Geostationary Earth Orbit), since the earth would break the transmission of laser and break the communication as well, so the effective time for each communication is very shot (several minutes~ dozens of minutes), as a result the communication terminals have to capture each other to rebuild the laser communication link. In the paper, on the basis of the analysis of the traditional methods, it presents a new idea that using the long beacon light instead of the circular beacon light; thereby the original of two-dimensional raster spiral scanning is replaced by one-dimensional scanning. This method will reduce the setup time and decrease the failure probability of acquisition for the LEO-GEO laser communication link. Firstly, the analysis of the external constraint conditions in the acquisition phase has been presented in this paper. Furthermore, the acquisition algorithm models have been established. The optimization analysis for the parameters of the acquisition unit has been carried out, and the ground validation experiments of the acquisition strategy have also been performed. The experiments and analysis show that compared with traditional capturing methods, the method presented in this article can make the capturing time be shortened by about 40%, and the failure probability of capturing be reduced by about 30%. So, the method is significant for the LEO-GEO laser communication link.
Army’s Management of Gray Eagle Spare Parts Needs Improvement (REDACTED)
2016-04-29
contracting officers purchased Heavy Fuel Engine 2.0 Liter Turbochargers at an average unit cost of for a total value of General Atomics proposed...Liter Turbocharger to establish an accurate baseline and could potentially overpay on future contracts. See Figure 10 for a picture of the Heavy...Fuel Engine 2.0 Liter Turbocharger . 19 Federal Acquisition Regulation 15.402, “Pricing Policy,” May 29, 2014. 20 Federal Acquisition Regulation 15.404
The Acquisition Cost-Estimating Workforce. Census and Characteristics
2009-01-01
Abbreviations AAC Air Armament Center ACAT acquisition category ACEIT Automated Cost Estimating Integrated Tools AF Air Force AFB Air Force Base AFCAA Air...3 3 4 Automated Cost Estimating Integrated Tools ( ACEIT ) 0 1 12 6 Tecolotea training 0 0 10 5 Other 3 13 24 18 No training 18 4 29 18 Total 100 100...other sources, including AFIT, ACEIT ,9 or the contracting agency that employed them. The remain- ing 29 percent reported having received no training
1982-04-22
acquisition would be an obligation made by the Environmental Protection Agency to a State to aid in the construction of a sewage treatment plant ...DE 1 PINELLAS COUNTY-TREASURE IS. CON FT... 3 FIRE IS. INLET TO JONES BEACH CON NY 2 TOTAL ESTIMATED COST CURRENT BASELINE...HELLFIRE MISSILE SYSTEM EQP OH 418 :I:ND WASTE TREATMENT PLANT CON TN 345 HOSPITAL IMPROVEMENTS FT HOOD CON TX 339 MLRS
In vivo High Angular Resolution Diffusion-Weighted Imaging of Mouse Brain at 16.4 Tesla
Alomair, Othman I.; Brereton, Ian M.; Smith, Maree T.; Galloway, Graham J.; Kurniawan, Nyoman D.
2015-01-01
Magnetic Resonance Imaging (MRI) of the rodent brain at ultra-high magnetic fields (> 9.4 Tesla) offers a higher signal-to-noise ratio that can be exploited to reduce image acquisition time or provide higher spatial resolution. However, significant challenges are presented due to a combination of longer T 1 and shorter T 2/T2* relaxation times and increased sensitivity to magnetic susceptibility resulting in severe local-field inhomogeneity artefacts from air pockets and bone/brain interfaces. The Stejskal-Tanner spin echo diffusion-weighted imaging (DWI) sequence is often used in high-field rodent brain MRI due to its immunity to these artefacts. To accurately determine diffusion-tensor or fibre-orientation distribution, high angular resolution diffusion imaging (HARDI) with strong diffusion weighting (b >3000 s/mm2) and at least 30 diffusion-encoding directions are required. However, this results in long image acquisition times unsuitable for live animal imaging. In this study, we describe the optimization of HARDI acquisition parameters at 16.4T using a Stejskal-Tanner sequence with echo-planar imaging (EPI) readout. EPI segmentation and partial Fourier encoding acceleration were applied to reduce the echo time (TE), thereby minimizing signal decay and distortion artefacts while maintaining a reasonably short acquisition time. The final HARDI acquisition protocol was achieved with the following parameters: 4 shot EPI, b = 3000 s/mm2, 64 diffusion-encoding directions, 125×150 μm2 in-plane resolution, 0.6 mm slice thickness, and 2h acquisition time. This protocol was used to image a cohort of adult C57BL/6 male mice, whereby the quality of the acquired data was assessed and diffusion tensor imaging (DTI) derived parameters were measured. High-quality images with high spatial and angular resolution, low distortion and low variability in DTI-derived parameters were obtained, indicating that EPI-DWI is feasible at 16.4T to study animal models of white matter (WM) diseases. PMID:26110770
Accelerated radial Fourier-velocity encoding using compressed sensing.
Hilbert, Fabian; Wech, Tobias; Hahn, Dietbert; Köstler, Herbert
2014-09-01
Phase Contrast Magnetic Resonance Imaging (MRI) is a tool for non-invasive determination of flow velocities inside blood vessels. Because Phase Contrast MRI only measures a single mean velocity per voxel, it is only applicable to vessels significantly larger than the voxel size. In contrast, Fourier Velocity Encoding measures the entire velocity distribution inside a voxel, but requires a much longer acquisition time. For accurate diagnosis of stenosis in vessels on the scale of spatial resolution, it is important to know the velocity distribution of a voxel. Our aim was to determine velocity distributions with accelerated Fourier Velocity Encoding in an acquisition time required for a conventional Phase Contrast image. We imaged the femoral artery of healthy volunteers with ECG-triggered, radial CINE acquisition. Data acquisition was accelerated by undersampling, while missing data were reconstructed by Compressed Sensing. Velocity spectra of the vessel were evaluated by high resolution Phase Contrast images and compared to spectra from fully sampled and undersampled Fourier Velocity Encoding. By means of undersampling, it was possible to reduce the scan time for Fourier Velocity Encoding to the duration required for a conventional Phase Contrast image. Acquisition time for a fully sampled data set with 12 different Velocity Encodings was 40 min. By applying a 12.6-fold retrospective undersampling, a data set was generated equal to 3:10 min acquisition time, which is similar to a conventional Phase Contrast measurement. Velocity spectra from fully sampled and undersampled Fourier Velocity Encoded images are in good agreement and show the same maximum velocities as compared to velocity maps from Phase Contrast measurements. Compressed Sensing proved to reliably reconstruct Fourier Velocity Encoded data. Our results indicate that Fourier Velocity Encoding allows an accurate determination of the velocity distribution in vessels in the order of the voxel size. Thus, compared to normal Phase Contrast measurements delivering only mean velocities, no additional scan time is necessary to retrieve meaningful velocity spectra in small vessels. Copyright © 2013. Published by Elsevier GmbH.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hui, C; Beddar, S; Wen, Z
Purpose: The purpose of this study is to develop a technique to obtain four-dimensional (4D) magnetic resonance (MR) images that are more representative of a patient’s typical breathing cycle by utilizing an extended acquisition time while minimizing the image artifacts. Methods: The 4D MR data were acquired with the balanced steady state free precession in two-dimensional sagittal plane of view. Each slice was acquired repeatedly for about 15 s, thereby obtaining multiple images at each of the 10 phases in the respiratory cycle. This improves the probability that at least one of the images were acquired at the desired phasemore » during a regular breathing cycle. To create optimal 4D MR images, an iterative approach was used to identify the set of images that yielded the highest slice-to-slice similarity. To assess the effectiveness of the approach, the data set was truncated into periods of 7 s (50 time points), 11 s (75 time points) and the full 15 s (100 time points). The 4D MR images were then sorted with data of the three different acquisition periods for comparison. Results: In general, the 4D MR images sorted using data from longer acquisition periods showed less mismatched artifacts. In addition, the normalized cross correlation (NCC) between slices of a 4D volume increases with increased acquisition period. The average NCC was 0.791 from the 7 s period, 0.794 from the 11 s period and 0.796 from the 15 s period. Conclusion: Our preliminary study showed that extending the acquisition time with the proposed sorting technique can improve image quality and reduce artifact presence in the 4D MR images. Data acquisition over two breathing cycles is a good trade-off between artifact reduction and scan time. This research was partially funded by the the Center for Radiation Oncology Research from UT MD Anderson Cancer Center.« less
Kamesh Iyer, Srikant; Tasdizen, Tolga; Burgon, Nathan; Kholmovski, Eugene; Marrouche, Nassir; Adluru, Ganesh; DiBella, Edward
2016-09-01
Current late gadolinium enhancement (LGE) imaging of left atrial (LA) scar or fibrosis is relatively slow and requires 5-15min to acquire an undersampled (R=1.7) 3D navigated dataset. The GeneRalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) based parallel imaging method is the current clinical standard for accelerating 3D LGE imaging of the LA and permits an acceleration factor ~R=1.7. Two compressed sensing (CS) methods have been developed to achieve higher acceleration factors: a patch based collaborative filtering technique tested with acceleration factor R~3, and a technique that uses a 3D radial stack-of-stars acquisition pattern (R~1.8) with a 3D total variation constraint. The long reconstruction time of these CS methods makes them unwieldy to use, especially the patch based collaborative filtering technique. In addition, the effect of CS techniques on the quantification of percentage of scar/fibrosis is not known. We sought to develop a practical compressed sensing method for imaging the LA at high acceleration factors. In order to develop a clinically viable method with short reconstruction time, a Split Bregman (SB) reconstruction method with 3D total variation (TV) constraints was developed and implemented. The method was tested on 8 atrial fibrillation patients (4 pre-ablation and 4 post-ablation datasets). Blur metric, normalized mean squared error and peak signal to noise ratio were used as metrics to analyze the quality of the reconstructed images, Quantification of the extent of LGE was performed on the undersampled images and compared with the fully sampled images. Quantification of scar from post-ablation datasets and quantification of fibrosis from pre-ablation datasets showed that acceleration factors up to R~3.5 gave good 3D LGE images of the LA wall, using a 3D TV constraint and constrained SB methods. This corresponds to reducing the scan time by half, compared to currently used GRAPPA methods. Reconstruction of 3D LGE images using the SB method was over 20 times faster than standard gradient descent methods. Copyright © 2016 Elsevier Inc. All rights reserved.
The Relationship between STD Locus of Control and STD Acquisition among Adolescent Girls.
ERIC Educational Resources Information Center
Rosenthal, Susan L.; Griffith, Jennifer O.; Succop, Paul A.; Biro, Frank M.; Lewis, Lisa M.; DeVellis, Robert F.; Stanberry, Lawrence R.
2002-01-01
Adolescent girls from an urban-based clinic participated in a longitudinal study about psychosexual development and risk of STD acquisition. The girls were asked about their perceptions of loci of control (parents, internal control) as it relates to STD acquisition. Responses to locus of control correlated over time but variations were not found…
ERIC Educational Resources Information Center
Rice, Mabel L.; Wexler, Kenneth; Hershberger, Scott
1998-01-01
A longitudinal study of 43 typical children (ages 2 to 8) and 21 children with specific language impairments (SLI) found that a diverse set of morphemes share the property of tense marking, that acquisition shows linear and nonlinear components, and that mean length of utterance predicts rate of acquisition. (Author/CR)
26 CFR 1.595-1 - Treatment of foreclosed property by certain creditors.
Code of Federal Regulations, 2013 CFR
2013-04-01
... held for productive use or for investment), or section 1033 (relating to involuntary conversions). For... acquisition, X incurs expenses totaling $500 for maintenance, and during the period June 1 through September 30, 1964, rents the property for a total rental of $400. Under local law, X is accountable to A for...
26 CFR 1.595-1 - Treatment of foreclosed property by certain creditors.
Code of Federal Regulations, 2011 CFR
2011-04-01
... held for productive use or for investment), or section 1033 (relating to involuntary conversions). For... acquisition, X incurs expenses totaling $500 for maintenance, and during the period June 1 through September 30, 1964, rents the property for a total rental of $400. Under local law, X is accountable to A for...
26 CFR 1.595-1 - Treatment of foreclosed property by certain creditors.
Code of Federal Regulations, 2010 CFR
2010-04-01
... held for productive use or for investment), or section 1033 (relating to involuntary conversions). For... acquisition, X incurs expenses totaling $500 for maintenance, and during the period June 1 through September 30, 1964, rents the property for a total rental of $400. Under local law, X is accountable to A for...
26 CFR 1.595-1 - Treatment of foreclosed property by certain creditors.
Code of Federal Regulations, 2012 CFR
2012-04-01
... held for productive use or for investment), or section 1033 (relating to involuntary conversions). For... acquisition, X incurs expenses totaling $500 for maintenance, and during the period June 1 through September 30, 1964, rents the property for a total rental of $400. Under local law, X is accountable to A for...
26 CFR 1.595-1 - Treatment of foreclosed property by certain creditors.
Code of Federal Regulations, 2014 CFR
2014-04-01
... held for productive use or for investment), or section 1033 (relating to involuntary conversions). For... acquisition, X incurs expenses totaling $500 for maintenance, and during the period June 1 through September 30, 1964, rents the property for a total rental of $400. Under local law, X is accountable to A for...
ERIC Educational Resources Information Center
Combs, Joseph, Jr.
1995-01-01
Reviews the Total Library Computerization program, which can be used to manage small to midsized libraries. Discusses costs; operating system requirements; security features; user-interface styles; and system modules including online cataloging, circulation, serials control, acquisitions, authorities control, and interlibrary loan. (Author/JMV)
A real-time spectrum acquisition system design based on quantum dots-quantum well detector
NASA Astrophysics Data System (ADS)
Zhang, S. H.; Guo, F. M.
2016-01-01
In this paper, we studied the structure characteristics of quantum dots-quantum well photodetector with response wavelength range from 400 nm to 1000 nm. It has the characteristics of high sensitivity, low dark current and the high conductance gain. According to the properties of the quantum dots-quantum well photodetectors, we designed a new type of capacitive transimpedence amplifier (CTIA) readout circuit structure with the advantages of adjustable gain, wide bandwidth and high driving ability. We have implemented the chip packaging between CTIA-CDS structure readout circuit and quantum dots detector and tested the readout response characteristics. According to the timing signals requirements of our readout circuit, we designed a real-time spectral data acquisition system based on FPGA and ARM. Parallel processing mode of programmable devices makes the system has high sensitivity and high transmission rate. In addition, we realized blind pixel compensation and smoothing filter algorithm processing to the real time spectrum data by using C++. Through the fluorescence spectrum measurement of carbon quantum dots and the signal acquisition system and computer software system to realize the collection of the spectrum signal processing and analysis, we verified the excellent characteristics of detector. It meets the design requirements of quantum dot spectrum acquisition system with the characteristics of short integration time, real-time and portability.
APNEA list mode data acquisition and real-time event processing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hogle, R.A.; Miller, P.; Bramblett, R.L.
1997-11-01
The LMSC Active Passive Neutron Examinations and Assay (APNEA) Data Logger is a VME-based data acquisition system using commercial-off-the-shelf hardware with the application-specific software. It receives TTL inputs from eighty-eight {sup 3}He detector tubes and eight timing signals. Two data sets are generated concurrently for each acquisition session: (1) List Mode recording of all detector and timing signals, timestamped to 3 microsecond resolution; (2) Event Accumulations generated in real-time by counting events into short (tens of microseconds) and long (seconds) time bins following repetitive triggers. List Mode data sets can be post-processed to: (1) determine the optimum time bins formore » TRU assay of waste drums, (2) analyze a given data set in several ways to match different assay requirements and conditions and (3) confirm assay results by examining details of the raw data. Data Logger events are processed and timestamped by an array of 15 TMS320C40 DSPs and delivered to an embedded controller (PowerPC604) for interim disk storage. Three acquisition modes, corresponding to different trigger sources are provided. A standard network interface to a remote host system (Windows NT or SunOS) provides for system control, status, and transfer of previously acquired data. 6 figs.« less
Generalized serial search code acquisition - The equivalent circular state diagram approach
NASA Technical Reports Server (NTRS)
Polydoros, A.; Simon, M. K.
1984-01-01
A transform-domain method for deriving the generating function of the acquisition process resulting from an arbitrary serial search strategy is presented. The method relies on equivalent circular state diagrams, uses Mason's formula from flow-graph theory, and employs a minimum number of required parameters. The transform-domain approach is briefly described and the concept of equivalent circular state diagrams is introduced and exploited to derive the generating function and resulting mean acquisition time for three particular cases of interest, the continuous/center Z search, the broken/center Z search, and the expanding window search. An optimization of the latter technique is performed whereby the number of partial windows which minimizes the mean acquisition time is determined. The numerical results satisfy certain intuitive predictions and provide useful design guidelines for such systems.
A new data logger for integrated geophysical monitoring
NASA Astrophysics Data System (ADS)
Orazi, Massimo; Peluso, Rosario; Caputo, Antonio; Giudicepietro, Flora; Martini, Marcello
2015-04-01
GILDA digital recorder is a data logger developed at Osservatorio Vesuviano (INGV). It provides excellent data quality with low power consumption and low production cost. It is widely used in the multi-parametric monitoring networks of Neapolitan volcanoes and Stromboli volcano. We have improved the characteristics of GILDA recorder to realize a robust user-oriented acquisition system for integrated geophysical monitoring. We have designed and implemented new capabilities concerning the use of the low rate channels to get data of environmental parameters of the station. We also improved the stand-alone version of the data logger. This version can be particularly useful for scientific experiments and to rapidly upgrade permanent monitoring networks. Furthermore, the local storage can be used as back-up for the monitoring systems in continuous transmission, in case of failure of the transmission system. Some firmware changes have been made in order to improve the performance of the instrument. In particular, the low rate acquisition channels were conditioned to acquire internal parameters of the recorder such as the temperature and voltage. A prototype of the new version of the logger is currently installed at Campi Flegrei for a experimental application. Our experiment is aimed at testing the new version of GILDA data logger in multi-board configuration for multiparametric acquisitions. A second objective of the experiment is the comparison of the recorded data with geochemical data acquired by a multiparametric geochemical station to investigate possible correlations between seismic and geochemical parameters. The target site of the experiment is "Bocca Grande" fumarole in Solfatara volcano. By exploiting the modularity of GILDA, for the experiment has been realized an acquisition system based on three dataloggers for a total of 12 available channels. One of GILDA recorders is the Master and the other two are Slaves. The Master is responsible for the initial configuration of the GPS receiver for timing data. The two data loggers configured in slave mode await the end of the initial configuration and then receive the GPS timing data and PPS from the Master. This allows you to use one GPS receiver and optimize power consumption. The whole system is configured to continuously transmit data via WiFi and to locally store data.
Measurement of gastric meal and secretion volumes using magnetic resonance imaging
NASA Astrophysics Data System (ADS)
Hoad, C. L.; Parker, H.; Hudders, N.; Costigan, C.; Cox, E. F.; Perkins, A. C.; Blackshaw, P. E.; Marciani, L.; Spiller, R. C.; Fox, M. R.; Gowland, P. A.
2015-02-01
MRI can assess multiple gastric functions without ionizing radiation. However, time consuming image acquisition and analysis of gastric volume data, plus confounding of gastric emptying measurements by gastric secretions mixed with the test meal have limited its use to research centres. This study presents an MRI acquisition protocol and analysis algorithm suitable for the clinical measurement of gastric volume and secretion volume. Reproducibility of gastric volume measurements was assessed using data from 10 healthy volunteers following a liquid test meal with rapid MRI acquisition within one breath-hold and semi-automated analysis. Dilution of the ingested meal with gastric secretion was estimated using a respiratory-triggered T1 mapping protocol. Accuracy of the secretion volume measurements was assessed using data from 24 healthy volunteers following a mixed (liquid/solid) test meal with MRI meal volumes compared to data acquired using gamma scintigraphy (GS) on the same subjects studied on a separate study day. The mean ± SD coefficient of variance between 3 observers for both total gastric contents (including meal, secretions and air) and just the gastric contents (meal and secretion only) was 3 ± 2% at large gastric volumes (>200 ml). Mean ± SD secretion volumes post meal ingestion were 64 ± 51 ml and 110 ± 40 ml at 15 and 75 min, respectively. Comparison with GS meal volumes, showed that MRI meal only volume (after correction for secretion volume) were similar to GS, with a linear regression gradient ± std err of 1.06 ± 0.10 and intercept -11 ± 24 ml. In conclusion, (i) rapid volume acquisition and respiratory triggered T1 mapping removed the requirement to image during prolonged breath-holds (ii) semi-automatic analysis greatly reduced the time required to derive measurements and (iii) correction for secretion volumes provided accurate assessment of gastric meal volumes and emptying. Together these features provide the scientific basis of a protocol which would be suitable in clinical practice.
Oldenburg, Catherine E; Bärnighausen, Till; Tanser, Frank; Iwuji, Collins C; De Gruttola, Victor; Seage, George R; Mimiaga, Matthew J; Mayer, Kenneth H; Pillay, Deenan; Harling, Guy
2016-08-15
Antiretroviral therapy (ART) was highly efficacious in preventing human immunodeficiency virus (HIV) transmission in stable serodiscordant couples in the HPTN-052 study, a resource-intensive randomized controlled trial with near-perfect ART adherence and mutual HIV status disclosure among all participating couples. However, minimal evidence exists of the effectiveness of ART in preventing HIV acquisition in stable serodiscordant couples in "real-life" population-based settings in hyperendemic communities of sub-Saharan Africa, where health systems are typically resource-poor and overburdened, adherence to ART is often low, and partners commonly do not disclose their HIV status to each other. Data arose from a population-based open cohort in KwaZulu-Natal, South Africa. A total of 17 016 HIV-uninfected individuals present between January 2005 and December 2013 were included. Interval-censored time-updated proportional hazards regression was used to assess how the ART status affected HIV transmission risk in stable serodiscordant relationships. We observed 1619 HIV seroconversions in 17 016 individuals, over 60 349 person-years follow-up time. During the follow-up period, 1846 individuals had an HIV-uninfected and 196 had an HIV-infected stable partner HIV incidence was 3.8/100 person-years (PY) among individuals with an HIV-infected partner (95% confidence interval [CI], 2.3-5.6), 1.4/100 PY (.4-3.5) among those with HIV-infected partners receiving ART, and 5.6/100 PY (3.5-8.4) among those with HIV-infected partners not receiving ART. Use of ART was associated with a 77% decrease in HIV acquisition risk among serodiscordant couples (adjusted hazard ratio, 0.23; 95% CI, .07-.80). ART initiation was associated with a very large reduction in HIV acquisition in serodiscordant couples in rural KwaZulu-Natal. However, this "real-life" effect was substantially lower than the effect observed in the HPTN-052 trial. To eliminate HIV transmission in serodiscordant couples, additional prevention interventions are probably needed. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America.
Investigation of a Combined Surveying and Scanning Device: The Trimble SX10 Scanning Total Station
Lachat, Elise; Landes, Tania; Grussenmeyer, Pierre
2017-01-01
Surveying fields from geosciences to infrastructure monitoring make use of a wide range of instruments for accurate 3D geometry acquisition. In many cases, the Terrestrial Laser Scanner (TLS) tends to become an optimal alternative to total station measurements thanks to the high point acquisition rate it offers, but also to ever deeper data processing software functionalities. Nevertheless, traditional surveying techniques are valuable in some kinds of projects. Nowadays, a few modern total stations combine their conventional capabilities with those of a laser scanner in a unique device. The recent Trimble SX10 scanning total station is a survey instrument merging high-speed 3D scanning and the capabilities of an image-assisted total station. In this paper this new instrument is introduced and first compared to state-of-the-art image-assisted total stations. The paper also addresses the topic of various laser scanning projects and the delivered point clouds are compared with those of other TLS. Directly and indirectly georeferenced projects have been carried out and are investigated in this paper, and a polygonal traverse is performed through a building. Comparisons with the results delivered by well-established survey instruments show the reliability of the Trimble SX10 for geodetic work as well as for scanning projects. PMID:28362319
Single-Shot X-Ray Phase-Contrast Computed Tomography with Nonmicrofocal Laboratory Sources
NASA Astrophysics Data System (ADS)
Diemoz, P. C.; Hagen, C. K.; Endrizzi, M.; Minuti, M.; Bellazzini, R.; Urbani, L.; De Coppi, P.; Olivo, A.
2017-04-01
We present a method that enables performing x-ray phase-contrast imaging (XPCI) computed tomography with a laboratory setup using a single image per projection angle, eliminating the need to move optical elements during acquisition. Theoretical derivation of the method is presented, and its validity conditions are provided. The object is assumed to be quasihomogeneous, i.e., to feature a ratio between the refractive index and the linear attenuation coefficient that is approximately constant across the field of view. The method is experimentally demonstrated on a plastics phantom and on biological samples using a continuous rotation acquisition scheme achieving scan times of a few minutes. Moreover, we show that such acquisition times can be further reduced with the use of a high-efficiency photon-counting detector. Thanks to its ability to substantially simplify the image-acquisition procedure and greatly reduce collection times, we believe this method represents a very important step towards the application of XPCI to real-world problems.
48 CFR 2901.603-70 - Responsibility of other government personnel.
Code of Federal Regulations, 2012 CFR
2012-10-01
... LABOR GENERAL DEPARTMENT OF LABOR ACQUISITION REGULATION SYSTEM Career Development, Contracting.... This will be mutually beneficial in terms of better planning for acquisition action and more timely...
48 CFR 2901.603-70 - Responsibility of other government personnel.
Code of Federal Regulations, 2014 CFR
2014-10-01
... LABOR GENERAL DEPARTMENT OF LABOR ACQUISITION REGULATION SYSTEM Career Development, Contracting.... This will be mutually beneficial in terms of better planning for acquisition action and more timely...
48 CFR 2901.603-70 - Responsibility of other government personnel.
Code of Federal Regulations, 2013 CFR
2013-10-01
... LABOR GENERAL DEPARTMENT OF LABOR ACQUISITION REGULATION SYSTEM Career Development, Contracting.... This will be mutually beneficial in terms of better planning for acquisition action and more timely...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tipton, C; Lamba, M; Qi, Z
Purpose: Cognitive impairment from radiation therapy to the brain may be linked to the loss of total blood volume in the brain. To account for brain injury, it is crucial to develop an understanding of blood volume loss as a result of radiation therapy. This study investigates µCT based quantification of mouse brain vasculature, focusing on the effect of acquisition technique and contrast material. Methods: Four mice were scanned on a µCT scanner (Siemens Inveon). The reconstructed voxel size was 18µm3 and all protocols were Hounsfield Unit (HU) calibrated. The mice were injected with 40mg of gold nanoparticles (MediLumine) ormore » 100µl of Exitron 12000 (Miltenyi Biotec). Two acquisition techniques were also performed. A single kVp technique scanned the mouse once using an x-ray beam of 80kVp and segmentation was completed based on a threshold of HU values. The dual kVp technique scanned the mouse twice using 50kVp and 80kVp, this segmentation was based on the ratio of the HU value of the two kVps. After image reconstruction and segmentation, the brain blood volume was determined as a percentage of the total brain volume. Results: For the single kVp acquisition at 80kVp, the brain blood volume had an average of 3.5% for gold and 4.0% for Exitron 12000. Also at 80kVp, the contrast-noise ratio was significantly better for images acquired with the gold nanoparticles (2.0) than for those acquired with the Exitron 12000 (1.4). The dual kVp acquisition shows improved separation of skull from vasculature, but increased image noise. Conclusion: In summary, the effects of acquisition technique and contrast material for quantification of mouse brain vasculature showed that gold nanoparticles produced more consistent segmentation of brain vasculature than Exitron 12000. Also, dual kVp acquisition may improve the accuracy of brain vasculature quantification, although the effect of noise amplification warrants further study.« less
Psoter, Kevin J; De Roos, Anneclaire J; Wakefield, Jon; Mayer, Jonathan D; Rosenfeld, Margaret
2017-06-09
Seasonal variations are often observed for respiratory tract infections; however, limited information is available regarding seasonal patterns of acquisition of common cystic fibrosis (CF)-related respiratory pathogens. We previously reported differential seasonal acquisition of Pseudomonas aeruginosa in young children with CF and no such variation for methicillin-susceptible Staphylococcus aureus acquisition. The purpose of this study was to describe and compare the seasonal incidence of acquisition of other respiratory bacterial pathogens in young children with CF. We conducted a retrospective study to describe and compare the seasonal incidence of methicillin-resistant Staphylococcus aureus (MRSA), Stenotrophomonas maltophilia, Achromobacter xylosoxidans, and Haemophilus influenzae acquisition in young CF patients residing in the U.S. using the Cystic Fibrosis Foundation National Patient Registry, 2003-2009. Log-linear overdispersed Poisson regression was used to evaluate seasonal acquisition of each of these pathogens. A total of 4552 children met inclusion criteria. During follow-up 910 (20%), 1161 (26%), 228 (5%), and 2148 (47%) children acquired MRSA, S. maltophilia, A. xylosoxidans and H. influenzae, respectively. Compared to winter season, MRSA was less frequently acquired in spring (Incidence Rate Ratio [IRR]: 0.79; 95% Confidence Interval [CI]: 0.65, 0.96) and summer (IRR: 0.69; 95% CI: 0.57, 0.84) seasons. Similarly, a lower rate of A. xylosoxidans acquisition was observed in spring (IRR: 0.59; 95% CI: 0.39, 0.89). For H. influenzae, summer (IRR: 0.88; 95% CI: 0.78, 0.99) and autumn (IRR: 0.78; 95% CI: 0.69, 0.88) seasons were associated with lower acquisition rates compared to winter. No seasonal variation was observed for S. maltophilia acquisition. Acquisition of CF-related respiratory pathogens displays seasonal variation in young children with CF, with the highest rate of acquisition for most pathogens occurring in the winter. Investigation of factors underlying these observed associations may contribute to our understanding of the aetiology of these infections and guide future infection control strategies.
The Dynamics of Community Health Care Consolidation: Acquisition of Physician Practices
Christianson, Jon B; Carlin, Caroline S; Warrick, Louise H
2014-01-01
Context Health care delivery systems are becoming increasingly consolidated in urban areas of the United States. While this consolidation could increase efficiency and improve quality, it also could raise the cost of health care for payers. This article traces the consolidation trajectory in a single community, focusing on factors influencing recent acquisitions of physician practices by integrated delivery systems. Methods We used key informant interviews, supplemented by document analysis. Findings The acquisition of physician practices is a process that will be difficult to reverse in the current health care environment. Provider revenue uncertainty is a key factor driving consolidation, with public and private attempts to control health care costs contributing to that uncertainty. As these efforts will likely continue, and possibly intensify, community health care systems now are less consolidated than they will be in the future. Acquisitions of multispecialty and primary care practices by integrated delivery systems follow a common process, with relatively predictable issues relating to purchase agreements, employment contracts, and compensation. Acquisitions of single-specialty practices are less common, with motivations for acquisitions likely to vary by specialty type, group size, and market structure. Total cost of care contracting could be an important catalyst for practice acquisitions in the future. Conclusions In the past, market and regulatory forces aimed at controlling costs have both encouraged and rewarded the consolidation of providers, with important new developments likely to create momentum for further consolidation, including acquisitions of physician practices. PMID:25199899
The dynamics of community health care consolidation: acquisition of physician practices.
Christianson, Jon B; Carlin, Caroline S; Warrick, Louise H
2014-09-01
Health care delivery systems are becoming increasingly consolidated in urban areas of the United States. While this consolidation could increase efficiency and improve quality, it also could raise the cost of health care for payers. This article traces the consolidation trajectory in a single community, focusing on factors influencing recent acquisitions of physician practices by integrated delivery systems. We used key informant interviews, supplemented by document analysis. The acquisition of physician practices is a process that will be difficult to reverse in the current health care environment. Provider revenue uncertainty is a key factor driving consolidation, with public and private attempts to control health care costs contributing to that uncertainty. As these efforts will likely continue, and possibly intensify, community health care systems now are less consolidated than they will be in the future. Acquisitions of multispecialty and primary care practices by integrated delivery systems follow a common process, with relatively predictable issues relating to purchase agreements, employment contracts, and compensation. Acquisitions of single-specialty practices are less common, with motivations for acquisitions likely to vary by specialty type, group size, and market structure. Total cost of care contracting could be an important catalyst for practice acquisitions in the future. In the past, market and regulatory forces aimed at controlling costs have both encouraged and rewarded the consolidation of providers, with important new developments likely to create momentum for further consolidation, including acquisitions of physician practices. © 2014 Milbank Memorial Fund.
Low Cost Coherent Doppler Lidar Data Acquisition and Processing
NASA Technical Reports Server (NTRS)
Barnes, Bruce W.; Koch, Grady J.
2003-01-01
The work described in this paper details the development of a low-cost, short-development time data acquisition and processing system for a coherent Doppler lidar. This was done using common laboratory equipment and a small software investment. This system provides near real-time wind profile measurements. Coding flexibility created a very useful test bed for new techniques.
Measures of Reliability in Behavioral Observation: The Advantage of "Real Time" Data Acquisition.
ERIC Educational Resources Information Center
Hollenbeck, Albert R.; Slaby, Ronald G.
Two observers who were using an electronic digital data acquisition system were spot checked for reliability at random times over a four month period. Between-and within-observer reliability was assessed for frequency, duration, and duration-per-event measures of four infant behaviors. The results confirmed the problem of observer drift--the…
ERIC Educational Resources Information Center
Kehoe, E. James; Ludvig, Elliot A.; Sutton, Richard S.
2014-01-01
The present experiment tested whether or not the time course of a conditioned eyeblink response, particularly its duration, would expand and contract, as the magnitude of the conditioned response (CR) changed massively during acquisition, extinction, and reacquisition. The CR duration remained largely constant throughout the experiment, while CR…