Relation of Mitral Valve Surgery Volume to Repair Rate, Durability, and Survival.
Chikwe, Joanna; Toyoda, Nana; Anyanwu, Anelechi C; Itagaki, Shinobu; Egorova, Natalia N; Boateng, Percy; El-Eshmawi, Ahmed; Adams, David H
2017-04-24
Degenerative mitral valve repair rates remain highly variable, despite established benefits of repair over replacement. The contribution of surgeon-specific factors is poorly defined. This study evaluated the influence of surgeon case volume on degenerative mitral valve repair rates and outcomes. A mandatory New York State database was queried and 5,475 patients were identified with degenerative mitral disease who underwent mitral valve operations between 2002 and 2013. Mitral repair rates, mitral reoperations within 12 months of repair, and survival were analyzed using multivariable Cox modeling and restricted cubic spline function. Median annual surgeon volume of any mitral operations was 10 (range 1 to 230), with a mean repair rate of 55% (n = 20,797 of 38,128). In the subgroup of patients with degenerative disease, the mean repair rate was 67% (n = 3,660 of 5,475), with a range of 0% to 100%. Mean repair rates ranged from 48% (n = 179 of 370) for surgeons with total annual volumes of ≤10 mitral operations to 77% (n = 1,710 of 2,216) for surgeons with total annual volumes of >50 mitral operations (p < 0.001). Higher total annual surgeon volume was associated with increased repair rates of degenerative mitral valve disease (adjusted odds ratio [OR]: 1.13 for every additional 10 mitral operations; 95% confidence interval [CI]: 1.10 to 1.17; p < 0.001); a steady decrease in reoperation risk until 25 total mitral operations annually; and improved 1-year survival (adjusted hazard ratio: 0.95 for every additional 10 operations; 95% CI: 0.92 to 0.98; p = 0.001). For surgeons with a total annual volume of ≤25 mitral operations, repair rates were higher (63.8%; n = 180 of 282) if they operated in the same institution as a surgeon with total annual mitral volumes of >50 and degenerative mitral valve repair rates of >70%, compared with surgeons operating in the other institutions (51.3%; n = 580 of 1,130) (adjusted OR: 1.79; 95% CI: 1.24 to 2.60; p < 0.001). This study suggests that individual surgeon volume is a determinant of not only mitral repair rates, but also freedom from reoperation, and survival. The data from this study support the guideline's concept of reference referral to experienced mitral surgeons to improve outcomes in patients with degenerative mitral valve disease. Copyright © 2017. Published by Elsevier Inc.
A Positive Move: 12th Annual College M&O Cost Study
ERIC Educational Resources Information Center
Agron, Joe
2006-01-01
Colleges placed more of an emphasis on maintenance and operations (M&O) this school year by increasing the amount spent on M&O as a percentage of total budget. According to "American School & University's" 12th annual College Maintenance and Operations Cost Study, spending on M&O as a percentage of total college budget increased to 11 percent from…
DOT National Transportation Integrated Search
2008-01-01
In FY 2008, Amtrak earned approximately $2.45 billion in total revenue and incurred about $3.41 billion in : expenses. The annual federal appropriation on which Amtrak relies : totaled $1.325 billion in FY 2008, comprising $475 million in : operating...
DOT National Transportation Integrated Search
2009-01-01
In FY 2009, Amtrak earned just over $2.35 billion in total revenue and incurred $3.5 billion in expenses. The annual federal : appropriation on which Amtrak relies totaled $1.49 billion in FY 2009, comprising $475 million in operating funds, $75 : mi...
36th Annual Maintenance & Operations Cost Study: Schools
ERIC Educational Resources Information Center
Agron, Joe
2007-01-01
Spending by school districts on maintenance and operations increased in 2006-2007, reversing years of historic low expenditures. According to "American School & University's" 36th annual Maintenance and Operations (M&O) Cost Study, the median school district spends 9.19% of total district expenditures (TDE) on M&O, up from 7.58% the year before.…
36th Annual Maintenance & Operations Cost Study: Colleges
ERIC Educational Resources Information Center
Agron, Joe
2007-01-01
Colleges are focusing increased effort--and money--to improve the physical condition of existing facilities and address a huge backlog of deferred maintenance. According to "American School & University's" 36th annual Maintenance and Operations (M&O) Cost Study, the median college spends 16.4% of total college budget on M&O, up from 11% the year…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-22
..., 332, 336, and 337. Total Annual Burden: 32,925 hours. Total Annual Cost: $1,625,000. Privacy Act... MHz band, and more are expected to commence operation soon. Interference from wireless microphones... Commission provides for these early clearing and consumer disclosure measures to commence as early as...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-18
... other for-profit, not-for-profit institutions. Total Respondents: 25. Total Annual Responses: 100... Burden Cost (capital/startup): $0. Total Burden Cost (operating/maintenance): $47. Comments submitted in...
77 FR 65900 - Agency Information Collection Activities: Delivery Ticket
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-31
... keepers from the collection of information (total capital/startup costs and operations and maintenance.... Estimated Number of Total Annual Responses: 200,000. Estimated Time per Response: 20 minutes. Estimated...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-20
... Number: LS-426. Affected Public: Individuals or households. Total Respondents: 1,100. Total Annual Responses: 1,100. Estimated Total Burden Hours: 275. Estimated Time per Response: 15 minutes. Frequency: On occasion. Total Burden Cost (capital/startup): $0. Total Burden Cost (operating/maintenance): $528.00...
How much tumor surgery do early-career orthopaedic oncologists perform?
Miller, Benjamin J; Rajani, Rajiv; Leddy, Lee; Carmody Soni, Emily E; White, Jeremy R
2015-02-01
There are few data on the types of procedures orthopaedic oncologists perform in their first years of practice. Because fellowships are graduating fellows each year and the number of tumor patients is limited, defining the practice patterns of early-career orthopaedic oncologists may help diminish early employment discontent and enhance workforce discussions. The aim of the study was to use the objective case log volumes of a cross-section of early career orthopaedic oncologists to describe (1) the number of operations performed annually; (2) the proportion of tumor, trauma, adult reconstruction, and other operations for individual participants, (3) individual practice characteristics that were associated with the number of tumor procedures; and (4) the sources of satisfaction and challenges in each individual's career and surgical practice. Fifteen fellowship-trained orthopaedic oncologists out of a potential pool of 33 (45%) in their first 4 years of practice responded to a survey by submitting complete operative case lists for a 2-year period. We recorded the type of procedure and determined associations between the annual number of tumor operations and total operative caseload, years in practice, and some details of individual practice patterns. Each participant completed a survey regarding practice-related sources of stress and satisfaction. A total of 5611 surgical cases were available for review. For the entire cohort, there were 3303 (59%) tumor procedures, 973 (17%) trauma, 890 (16%) adult reconstruction, and 445 (8%) other. The median annual number of total operations was 214 (range, 63-356) and median annual number of tumor operations was 135 (range, 47-216). The median proportion of tumor operations in an individual practice was 56% (range, 43%-94%). The annual number of tumor operations correlated with the total annual number of operations (r = 0.73, p < 0.001). Sources of stress and satisfaction were similar to the general membership of the Musculoskeletal Tumor Society (MSTS), apart from more early-career surgeons regarding case volume as important (29 of 104 [28%] of MSTS versus 11 of 15 [73%] of early-career, p < 0.001). The typical early-career orthopaedic tumor surgeon had fewer than 60% of his or her operative procedures directly related to the subject of his or her fellowship training in orthopaedic oncology. Overall, the challenges and rewards of clinical practice are similar to oncologic surgeons later in their career. This study is a first step in assessing early practice characteristics and may be of value to the prospective orthopaedic oncologist, fellowship educators, and the society in workforce discussions. Early-career practice patterns have not been previously presented, to our knowledge, for any subspecialty of orthopaedic surgery, and we hope that this study will stimulate similar efforts throughout the field. Level IV, economic and decision analyses. See Guidelines for Authors for a complete description of levels of evidence.
77 FR 10761 - Agency Information Collection Activities: Screening Requirements for Carriers
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-23
... the collection of information (a total capital/ startup costs and operations and maintenance costs... per Respondent: 100 hours. Estimated Total Annual Burden Hours: 6,500. Dated: February 17, 2012...
76 FR 56213 - Agency Information Collection Activities: Crew's Effects Declaration
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-12
... keepers from the collection of information (a total capital/startup costs and operations and maintenance... Responses: 206,100. Estimated Time per Response: 60 minutes. Estimated Total Annual Burden Hours: 206,100...
75 FR 57284 - Agency Information Collection Activities: Cost Submission
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-20
... respondents or record keepers from the collection of information (a total capital/startup costs and operations... Respondent: 1. Estimated time per Response: 50 hours. Estimated Total Annual Burden Hours: 50,000. [[Page...
75 FR 57480 - Agency Information Collection Activities: Commercial Invoice
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-21
... respondents or record keepers from the collection of information (a total capital/startup costs and operations... Responses per Respondent: 1,208. Estimated Number of Total Annual Responses: 46,500,000. Estimated time per...
76 FR 23542 - Proposed Information Collection; Comment Request; Annual Retail Trade Survey
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-27
... e- commerce sales, year-end inventories held inside and outside the United States, total operating... of sales by class of customer, and percent of e-commerce sales to customers located outside the... DEPARTMENT OF COMMERCE U.S. Census Bureau Proposed Information Collection; Comment Request; Annual...
77 FR 22806 - Proposed Extension of Existing Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-17
... annually. Total Burden Cost (capital/startup): $0. Total Burden Cost (operating/maintenance): $45,979... (Section 8(f) Payments) 1,425 ESA-100 (20 SFR 702.201) 840 LS-271 (Self Insurance Application) 60 LS-274...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-18
... keepers from the collection of information (a total capital/startup costs and operations and maintenance.... Estimated Time per Response: 10 minutes. Estimated Total Annual Burden Hours: 896,400 hours. Dated...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-13
... keepers from the collection of information (a total capital/startup costs and operations and maintenance... Number of Respondents: 28,000. Estimated Total Annual Responses: 28,000. Estimated Time per Respondent...
76 FR 70765 - National Endowment for the Arts; Submission of OMB Review: Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-15
... submission of responses. Agency: National Endowment for the Arts. Title: General Social Survey Arts... Annualized Capital/Startup Costs: 0. Total Annual Costs (Operating/Maintaining Systems or Purchasing Services): 0. This request is for clearance of an arts supplement for the 2012 General Social Survey (GSS), to...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-28
... of information (a total capital/startup costs and operations and maintenance costs). The comments... Number of Respondents: 100,000. Estimated Number of Total Annual Responses: 100,000. Estimated Time per...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-30
... chartering and field of membership. 12 U.S.C. 1753(5), 1754, 1759. The NCUA Board, after consideration of...-owned, not-for-profit financial cooperative. Since a CU could not operate as a chartered and insured... Expansion Applications. Respondents: 39. Estimated annual burden: 160 hours. Total annual hours: 6,240...
GEOTHERMAL / SOLAR HYBRID DESIGNS: USE OF GEOTHERMAL ENERGY FOR CSP FEEDWATER HEATING
DOE Office of Scientific and Technical Information (OSTI.GOV)
Craig Turchi; Guangdong Zhu; Michael Wagner
2014-10-01
This paper examines a hybrid geothermal / solar thermal plant design that uses geothermal energy to provide feedwater heating in a conventional steam-Rankine power cycle deployed by a concentrating solar power (CSP) plant. The geothermal energy represents slightly over 10% of the total thermal input to the hybrid plant. The geothermal energy allows power output from the hybrid plant to increase by about 8% relative to a stand-alone CSP plant with the same solar-thermal input. Geothermal energy is converted to electricity at an efficiency of 1.7 to 2.5 times greater than would occur in a stand-alone, binary-cycle geothermal plant usingmore » the same geothermal resource. While the design exhibits a clear advantage during hybrid plant operation, the annual advantage of the hybrid versus two stand-alone power plants depends on the total annual operating hours of the hybrid plant. The annual results in this draft paper are preliminary, and further results are expected prior to submission of a final paper.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-06
... Burden: 1,780 hours. Total Annual Cost: $606,500. Privacy Impact Assessment: No impact(s). Nature and... stations to commence operation of FM digital facilities with operating power up to -14 dB upon notice to... days of commencing in-band, on channel (IBOC) digital operation. The notification must include the...
Proceedings: Sixth Annual Workshop on Meteorological and Environmental Inputs to Aviation Systems
NASA Technical Reports Server (NTRS)
Frost, W. (Editor); Camp, D. W. (Editor); Hershman, L. W. (Editor)
1983-01-01
The topics of interaction of the atmosphere with aviation systems, the better definition and implementation of services to operators, and the collection and interpretation of data for establishing operational criteria relating the total meteorological inputs from the atmospheric sciences to the needs of aviation communities were addressed.
75 FR 81560 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-28
... associated risk factors. As part of an ongoing series of NAHMS studies on the U.S. livestock population... study is designed to collect information on operations with total annual sales between $10,000 and $250... number. Animal and Plant Health Inspection Service Title: Small-Scale Livestock Operations 2011 Study...
7 CFR 205.101 - Exemptions and exclusions from certification.
Code of Federal Regulations, 2011 CFR
2011-01-01
... products as “organic” but whose gross agricultural income from organic sales totals $5,000 or less annually... from such operations shall not be used as ingredients identified as organic in processed products... organic ingredients by total weight of the finished product (excluding water and salt) is exempt from the...
76 FR 9806 - Agency Information Collection Activities: Notice of Detention
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-22
... keepers from the collection of information (a total capital/startup costs and operations and maintenance... in order to facilitate the determination for admissibility or may ask for an extension of time to... of Responses per Respondent: 1. Estimated Number of Total Annual Responses: 1,350. Estimated Time per...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-27
... in the public docket without change including any personal information provided, unless the comment...: 144 (total). Frequency of response: Initially, quarterly, and semiannually. Total estimated burden: 23... year), includes $800 annualized capital or operation & maintenance costs. Changes in the Estimates...
NASA Technical Reports Server (NTRS)
Xia, Youlong; Cosgrove, Brian A.; Mitchell, Kenneth E.; Peters-Lidard, Christa D.; Ek, Michael B.; Brewer, Michael; Mocko, David; Kumar, Sujay V.; Wei, Helin; Meng, Jesse;
2016-01-01
The purpose of this study is to evaluate the components of the land surface water budget in the four land surface models (Noah, SAC-Sacramento Soil Moisture Accounting Model, (VIC) Variable Infiltration Capacity Model, and Mosaic) applied in the newly implemented National Centers for Environmental Prediction (NCEP) operational and research versions of the North American Land Data Assimilation System version 2 (NLDAS-2). This work focuses on monthly and annual components of the water budget over 12 National Weather Service (NWS) River Forecast Centers (RFCs). Monthly gridded FLUX Network (FLUXNET) evapotranspiration (ET) from the Max-Planck Institute (MPI) of Germany, U.S. Geological Survey (USGS) total runoff (Q), changes in total water storage (dS/dt, derived as a residual by utilizing MPI ET and USGS Q in the water balance equation), and Gravity Recovery and Climate Experiment (GRACE) observed total water storage anomaly (TWSA) and change (TWSC) are used as reference data sets. Compared to these ET and Q benchmarks, Mosaic and SAC (Noah and VIC) in the operational NLDAS-2 overestimate (underestimate) mean annual reference ET and underestimate (overestimate) mean annual reference Q. The multimodel ensemble mean (MME) is closer to the mean annual reference ET and Q. An anomaly correlation (AC) analysis shows good AC values for simulated monthly mean Q and dS/dt but significantly smaller AC values for simulated ET. Upgraded versions of the models utilized in the research side of NLDAS-2 yield largely improved performance in the simulation of these mean annual and monthly water component diagnostics. These results demonstrate that the three intertwined efforts of improving (1) the scientific understanding of parameterization of land surface processes, (2) the spatial and temporal extent of systematic validation of land surface processes, and (3) the engineering-oriented aspects such as parameter calibration and optimization are key to substantially improving product quality in various land data assimilation systems.
Factors influencing specific fuel use in Nebraska
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shelton, D.P.; Von Bargen, K.
1981-01-01
Fuel use data relating to agricultural field operations were collected and analyzed during the Nebraska fuel use survey. The farms surveyed had a mean size of 598 ha and a mean total tractor power rating of 221 kW. Mean operating depth, field speed, and tractor power rating were determined for the major field operations. Mean field speeds were generally in agreement with commonly accepted values. Total annual fuel energy use increased with increasing farm size. Over 87 percent of this energy was used from April through October. Even though total fuel energy was increased, specific fuel energy use decreased withmore » increasing farm size. Specific fuel use for field operations was influenced by the size of area worked, operation depth, field speed, and tractor power rating.« less
78 FR 64523 - Agency Information Collection Activities: Vessel Entrance or Clearance Statement
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-29
... respondents or record keepers from the collection of information (a total capital/startup costs and operations... vessel data at time of formal entrance and clearance in U.S. ports. The form allows the master to attest... Responses per Respondent: 22. Estimated Total Annual Responses: 264,000. Estimated Time per Response: 30...
Optimal synthesis and design of the number of cycles in the leaching process for surimi production.
Reinheimer, M Agustina; Scenna, Nicolás J; Mussati, Sergio F
2016-12-01
Water consumption required during the leaching stage in the surimi manufacturing process strongly depends on the design and the number and size of stages connected in series for the soluble protein extraction target, and it is considered as the main contributor to the operating costs. Therefore, the optimal synthesis and design of the leaching stage is essential to minimize the total annual cost. In this study, a mathematical optimization model for the optimal design of the leaching operation is presented. Precisely, a detailed Mixed Integer Nonlinear Programming (MINLP) model including operating and geometric constraints was developed based on our previous optimization model (NLP model). Aspects about quality, water consumption and main operating parameters were considered. The minimization of total annual costs, which considered a trade-off between investment and operating costs, led to an optimal solution with lesser number of stages (2 instead of 3 stages) and higher volumes of the leaching tanks comparing with previous results. An analysis was performed in order to investigate how the optimal solution was influenced by the variations of the unitary cost of fresh water, waste treatment and capital investment.
76 FR 53117 - Information Collection; Submission for OMB Review, Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-25
... the Civic Health Assessment, an annual report that is mandated by the Serve America Act. Type of... Cost (capital/startup): None. Total Burden Cost (operating/maintenance): None. Dated: August 22, 2011...
Hardwood Chip Export Mills in Arkansas - Implications for Sustainability
John L. Gray; James M. Guldin
2001-01-01
Abstract - Two new hardwood chip export mills (HCEMâs) recently began operating in west-central Arkansas,and a third is planned. Together,they will require 1.1 million tons of nonhickory hardwood roundwood annually, primarily from the nonindustrial private sector. Overall, total physical and operable growth surpluses could support the new sector, but...
Revenue and Expenses of Ontario Universities, 1981-82. Volume IV, Physical Plant Operating Expenses.
ERIC Educational Resources Information Center
Council of Ontario Universities, Toronto. Research Div.
Results of an annual survey provide an analysis of physical plant costs by major functional area and object of expense, as reported in each university's operating fund. The principles observed in reporting, definitions, and explanatory comments on the cost categories and their scopes precede a series of summary tables for: total and percentage…
40 CFR 63.5340 - How do I determine the allowable HAP loss?
Code of Federal Regulations, 2010 CFR
2010-07-01
... appropriate HAP emission limit, expressed in pounds of HAP loss per 1,000 square feet of leather processed... the annual total of leather processed in 1,000's of square feet for each product process operation in... of square feet of leather processed in the previous 12 months in product process operation “i”. HAP...
40 CFR 63.5340 - How do I determine the allowable HAP loss?
Code of Federal Regulations, 2011 CFR
2011-07-01
... appropriate HAP emission limit, expressed in pounds of HAP loss per 1,000 square feet of leather processed... the annual total of leather processed in 1,000's of square feet for each product process operation in... of square feet of leather processed in the previous 12 months in product process operation “i”. HAP...
PROCEDURE FOR THE ESTABLISHMENT OF COMMUNITY JUNIOR COLLEGES IN ARKANSAS.
ERIC Educational Resources Information Center
Arkansas State Commission on Coordination of Higher Educational Finance, Little Rock.
CRITERIA FOR ESTABLISHMENT OF JUNIOR COLLEGE DISTRICTS IN ARKANSAS INCLUDE (1) A PROJECTED ENROLLMENT OF AT LEAST 300 FULL TIME EQUIVALENT STUDENTS IN THE THIRD YEAR OF OPERATION, (2) ASSESSED VALUATION ADEQUATE TO PROVIDE FROM LOCAL PROPERTY TAXES ONE-THIRD OF THE ANNUAL OPERATING COST AND THE TOTAL DEBT SERVICE REQUIREMENTS FOR CAPITAL OUTLAY,…
PREMChlor: Probabilistic Remediation Evaluation Model for Chlorinated Solvents
2010-03-01
Council O&M Operation & Management PAT pump-and-treat PCE tetrachloroethylene PDFs Probability density functions PRBs Permeable reactive barriers...includes a one-time capital cost and a total operation & management (O&M) cost in present net value (NPV) for a certain remediation period. The...Generally, the costs of plume treatment include the capital cost (treatment volume multiply by the unit cost) and the annual operation & Management (O&M
Abe, Katsumi; Kosuda, Shigeru; Kusano, Shoichi; Nagata, Masayoshi
2003-11-01
It is crucial to evaluate an annual balance before-hand when an institution installs a PET system because the revised Japanese national insurance reimbursement system set the cost of a FDG PET study as 75,000 yen. A break-even point was calculated in an 8-hour or a 24-hour operation of a PET system, based on the total costs reported. The break-even points were as follows: 13.4, 17.7, 22.1 studies per day for the 1 cyclotron-1 PET camera, 1 cyclotron-2 PET cameras, 1 cyclotron-3 PET cameras system, respectively, in an ordinary PET system operation of 8 hours. The break-even points were 19.9, 25.5, 31.2 studies per day for the 1 cyclotron-1 PET camera, 1 cyclotron-2 PET cameras, 1 cyclotron-3 PET cameras system, respectively, in a full PET system operation of 24 hours. The results indicate no profit would accrue in an ordinary PET system operation of 8 hours. The annual profit and break-even point for the total cost including the initial investment would be respectively 530 million yen and 2.8 years in a 24-hour operation with 1 cyclotron-3 PET cameras system.
1985-01-01
equipped with data collection platforms (DCP) by the end of FY 1985. (b) Communication. The DCP’s transmit the remote gaging station data over the...activated 78 platforms in FY 84 bringing the total number of operating stations to 85. Plans are to activate seven more platforms in FY 85. c. Acoustic... Platforms . The total program cost for FY 1984 is shown in Table VI-3. The total program cost for FY 1985 will be $172,720. (2) National Weather Service
77 FR 38886 - Proposed Information Collections; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-29
... of operation, maintenance, and purchase of services to provide the requested information. Information... of Respondents: 2,000. Estimated Total Annual Burden Hours: 500. Title: Formula and Process for Wine... the classification of wines for labeling and consumer protection purposes. The form describes the...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-16
.../startup costs and operations and maintenance costs). The comments that are submitted will be summarized... Number of Respondents: 100,000. Estimated Number of Total Annual Responses: 100,000. Estimated Time per...
Timber resource statistics for the Wood-Salcha Block, Tanana inventory unit, Alaska, 1975.
Kenneth C. Winterberger
1983-01-01
This statistical report on timber resources of the 4.1-million-acre Wood-Salcha block is the last of four reports on the 14-million-acre Tanana Valley inventory unit. Tables are provided for commercial and operable noncommercial forest land, total gross and net volumes, and annual net growth and mortality. Estimates for commercial forest land total 626,300 acres with...
Code of Federal Regulations, 2010 CFR
2010-07-01
... following requirements: (1) You must reduce your intake flow, at a minimum, to a level commensurate with... that the total design intake flow from all cooling water intake structures at your facility meets the... total design intake flow must be no greater than five (5) percent of the source water annual mean flow...
Economic analysis and assessment of syngas production using a modeling approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Hakkwan; Parajuli, Prem B.; Yu, Fei
Economic analysis and modeling are essential and important issues for the development of current feedstock and process technology for bio-gasification. The objective of this study was to develop an economic model and apply to predict the unit cost of syngas production from a micro-scale bio-gasification facility. An economic model was programmed in C++ computer programming language and developed using a parametric cost approach, which included processes to calculate the total capital costs and the total operating costs. The model used measured economic data from the bio-gasification facility at Mississippi State University. The modeling results showed that the unit cost ofmore » syngas production was $1.217 for a 60 Nm-3 h-1 capacity bio-gasifier. The operating cost was the major part of the total production cost. The equipment purchase cost and the labor cost were the largest part of the total capital cost and the total operating cost, respectively. Sensitivity analysis indicated that labor costs rank the top as followed by equipment cost, loan life, feedstock cost, interest rate, utility cost, and waste treatment cost. The unit cost of syngas production increased with the increase of all parameters with exception of loan life. The annual cost regarding equipment, labor, feedstock, waste treatment, and utility cost showed a linear relationship with percent changes, while loan life and annual interest rate showed a non-linear relationship. This study provides the useful information for economic analysis and assessment of the syngas production using a modeling approach.« less
77 FR 27802 - Proposed Collection; Comments Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-11
... Costs: 0. Total Annual Costs (Operating/Maintaining systems or Purchasing Services): 0. The National... following public information collection request (ICR) to the Office of Management and Budget (OMB) for... Endowment for the Arts, Office of Management and Budget, Room 10235, Washington, DC 20503 202/395-7316...
Estimating the cost to U.S. health departments to conduct HIV surveillance.
Shrestha, Ram K; Sansom, Stephanie L; Laffoon, Benjamin T; Farnham, Paul G; Shouse, R Luke; MacMaster, Karen; Hall, H Irene
2014-01-01
HIV case surveillance is a primary source of information for monitoring HIV burden in the United States and guiding the allocation of prevention and treatment funds. While the number of people living with HIV and the need for surveillance data have increased, little is known about the cost of surveillance. We estimated the economic cost to health departments of conducting high-quality HIV case surveillance. We collected primary data on the unit cost and quantity of resources used to operate the HIV case surveillance program in Michigan, where HIV burden (i.e., the number of HIV cases) is moderate to high (n=14,864 cases). Based on Michigan's data, we projected the expected annual HIV surveillance cost for U.S., state, local, and territorial health departments. We based our cost projection on the variation in the number of new and established cases, area-specific wages, and potential economies of scale. We estimated the annual total HIV surveillance cost to the Michigan health department to be $1,286,524 ($87/case), the annual total cost of new cases to be $108,657 ($133/case), and the annual total cost of established cases to be $1,177,867 ($84/case). Our projected median annual HIV surveillance cost per health department ranged from $210,600 in low-HIV burden sites to $1,835,000 in high-HIV burden sites. Our analysis shows that a systematic approach to costing HIV surveillance at the health department level is feasible. For HIV surveillance, a substantial portion of total surveillance costs is attributable to maintaining established cases.
Analysis of capital spending and capital financing among large US nonprofit health systems.
Stewart, Louis J
2012-01-01
This article examines the recent trends (2006 to 2009) in capital spending among 25 of the largest nonprofit health systems in the United States and analyzes the financing sources that these large nonprofit health care systems used to fund their capital spending. Total capital spending for these 25 nonprofit health entities exceeded $41 billion for the four-year period of this study. Less than 3 percent of total capital spending resulted in mergers and acquisition activities. Total annual capital spending grew at an average annual rate of 17.6 percent during the first three year of this study's period of analysis. Annual capital spending for 2009 fell by more than 22 percent over prior year's level due to the impact of widespread disruption in US tax-exempt variable rate debt markets. While cash inflow from long-term debt issues was a significant source of capital financing, this study's primary finding was that operating cash flow was the predominant source of capital spending funding. Key words: nonprofit, mergers and acquisitions (M&A), capital spending, capital financing.
Have the annual trends of total hip arthroplasty in rheumatoid arthritis patients decreased?
Onuoha, Kemjika O.; Solow, Max; Newman, Jared M.; Sodhi, Nipun; Pivec, Robert; Khlopas, Anton; Sultan, Assem A.; Chughtai, Morad; Shah, Neil V.; George, Jaiben
2017-01-01
Background Rheumatoid arthritis (RA) is characterized by chronic systemic and synovial inflammation, resulting in damage to both cartilage and bone. Medical treatment, which has increasingly relied upon disease modifying anti-rheumatic drugs (DMARDs), may fail to slow disease progression and limit joint damage, ultimately warranting surgical intervention. Up to 25% of RA patients will require lower extremity total joint arthroplasty. Though total hip arthroplasty (THA) is known to improve quality of life and functional measures, clarification is still required with respect to the impact of increased DMARD use on annual rates of THA. Thus, the purpose of this study was to evaluate: (I) the annual trends of THAs due to RA in the United States population; (II) the annual trends in the proportion of THAs due to RA in the United States. Methods This study utilized the Nationwide Inpatient Sample (NIS) to identify all patients who underwent THA between 2002 and 2013 (n=3,135,904). Then, THA patients who had a diagnosis of RA, which was defined by the International Classification of Disease 9th revision diagnosis code 714.0, were identified. The incidence of THAs with a diagnosis of RA in the United States was calculated using the United States population as the denominator. Regression models were used to analyze the annual trends of RA in patients who underwent THA. Results Review of the database identified 90,487 patients who had a diagnosis of RA and underwent THA from 2002 to 2013. The annual prevalence of RA in those who underwent THA slightly decreased over the specified time period, with 28.7 per 1,000 THAs in 2002 and 28.6 per 1,000 THAs in 2013; however, this change was not statistically significant (R2=0.158, P=0.200). Conclusions The annual rates of THA among RA patients did not show any significant change between 2002 and 2013. DMARD use has decreased both disease progression and joint destruction, and DMARDs are now often utilized as primary treatment. The increase in population of the country during the study period may have overestimated THA trends. Moreover, patients may be more likely to opt for surgical management, given the advances in operative techniques as well as peri- and post-operative course. PMID:29299482
75 FR 3765 - Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-22
... time for the annual audit report is 100 hours per OTC derivatives dealer, for a total of 180 hours per... Financial and Operational Combined Uniform Single (``FOCUS'') Report, is the basic document for reporting...). Rule 17a-12 requires registered OTC derivatives dealers to file Part IIB of the FOCUS Report quarterly...
76 FR 16816 - Agency Information Collection Activities: Proposed Collection, Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-25
... comment and provide your total capital and startup cost components or annual operation, maintenance, and..., including system and technology acquisition, expected useful life of capital equipment, discount rate(s), and the period over which you incur costs. Capital and startup costs include, among other items...
75 FR 60759 - Agency Information Collection Activities: Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-01
... Drug Program Monthly and Quarterly Drug Reporting Format; Use: In order for payment to be made under...: Private Sector: Business or other for-profits; Number of Respondents: 580; Total Annual Responses: 9,280..., 2010. Michelle Shortt, Director, Regulations Development Group, Office of Strategic Operations and...
14 CFR 1214.202 - Reimbursement policy.
Code of Federal Regulations, 2010 CFR
2010-01-01
... according to the reimbursement schedule plus short term call-up additional costs. The additional costs will... services. (2) The price will be based on estimated costs. (3) The price will be held constant for flights...) Subsequent to the first three years, the price will be adjusted annually to insure that total operating costs...
Dexter, Franklin; Blake, John T; Penning, Donald H; Sloan, Brian; Chung, Patricia; Lubarsky, David A
2002-03-01
Administrators at hospitals with a fixed annual budget may want to focus surgical services on priority areas to ensure its community receives the best health services possible. However, many hospitals lack the detailed managerial accounting data needed to ensure that such a change does not increase operating costs. The authors used a detailed hospital cost database to investigate by how much a change in allocations of operating room (OR) time among surgeons can increase perioperative variable costs. The authors obtained financial data for all patients who underwent outpatient or same-day admit surgery during a year. Linear programming was used to determine by how much changing the mix of surgeons can increase total variable costs while maintaining the same total hours of OR time for elective cases. Changing OR allocations among surgeons without changing total OR hours allocated will likely increase perioperative variable costs by less than 34%. If, in addition, intensive care unit hours for elective surgical cases are not increased, hospital ward occupancy is capped, and implant use is tracked and capped, perioperative costs will likely increase by less than 10%. These four variables predict 97% of the variance in total variable costs. The authors showed that changing OR allocations among surgeons without changing total OR hours allocated can increase hospital perioperative variable costs by up to approximately one third. Thus, at hospitals with fixed or nearly fixed annual budgets, allocating OR time based on an OR-based statistic such as utilization can adversely affect the hospital financially. The OR manager can reduce the potential increase in costs by considering not just OR time, but also the resulting use of hospital beds and implants.
Solving nuts-and-bolts nuclear problems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olmstead, A.; Schoen, J.
1979-05-01
The Operations and Maintenance Information Service (MIS), created and operated by NUS Corp., was designed to improve plant availability through the exchange of practical information between nuclear plants and a return to an emphasis on the problem-solving process. MIS meetings cover a range of plant problems and have been unique in bringing the rapid feedback of information pertinent to the day-to-day working operation of a total plant. Much of the response is by telephone contact, although the monthly newsletter, semi-annual meetings, and scheduled plant visits are also helpful.
Harden, Stephen L.; Cuffney, Thomas F.; Terziotti, Silvia; Kolb, Katharine R.
2013-01-01
Data collected between 1997 and 2008 at 48 stream sites were used to characterize relations between watershed settings and stream nutrient yields throughout central and eastern North Carolina. The focus of the investigation was to identify environmental variables in watersheds that influence nutrient export for supporting the development and prioritization of management strategies for restoring nutrient-impaired streams. Nutrient concentration data and streamflow data compiled for the 1997 to 2008 study period were used to compute stream yields of nitrate, total nitrogen (N), and total phosphorus (P) for each study site. Compiled environmental data (including variables for land cover, hydrologic soil groups, base-flow index, streams, wastewater treatment facilities, and concentrated animal feeding operations) were used to characterize the watershed settings for the study sites. Data for the environmental variables were analyzed in combination with the stream nutrient yields to explore relations based on watershed characteristics and to evaluate whether particular variables were useful indicators of watersheds having relatively higher or lower potential for exporting nutrients. Data evaluations included an examination of median annual nutrient yields based on a watershed land-use classification scheme developed as part of the study. An initial examination of the data indicated that the highest median annual nutrient yields occurred at both agricultural and urban sites, especially for urban sites having large percentages of point-source flow contributions to the streams. The results of statistical testing identified significant differences in annual nutrient yields when sites were analyzed on the basis of watershed land-use category. When statistical differences in median annual yields were noted, the results for nitrate, total N, and total P were similar in that highly urbanized watersheds (greater than 30 percent developed land use) and (or) watersheds with greater than 10 percent point-source flow contributions to streamflow had higher yields relative to undeveloped watersheds (having less than 10 and 15 percent developed and agricultural land uses, respectively) and watersheds with relatively low agricultural land use (between 15 and 30 percent). The statistical tests further indicated that the median annual yields for total P were statistically higher for watersheds with high agricultural land use (greater than 30 percent) compared to the undeveloped watersheds and watersheds with low agricultural land use. The total P yields also were higher for watersheds with low urban land use (between 10 and 30 percent developed land) compared to the undeveloped watersheds. The study data indicate that grouping and examining stream nutrient yields based on the land-use classifications used in this report can be useful for characterizing relations between watershed settings and nutrient yields in streams located throughout central and eastern North Carolina. Compiled study data also were analyzed with four regression tree models as a means of determining which watershed environmental variables or combination of variables result in basins that are likely to have high or low nutrient yields. The regression tree analyses indicated that some of the environmental variables examined in this study were useful for predicting yields of nitrate, total N, and total P. When the median annual nutrient yields for all 48 sites were evaluated as a group (Model 1), annual point-source flow yields had the greatest influence on nitrate and total N yields observed in streams, and annual streamflow yields had the greatest influence on yields of total P. The Model 1 results indicated that watersheds with higher annual point-source flow yields had higher annual yields of nitrate and total N, and watersheds with higher annual streamflow yields had higher annual yields of total P. When sites with high point-source flows (greater than 10 percent of total streamflow) were excluded from the regression tree analyses (Models 2–4), the percentage of forested land in the watersheds was identified as the primary environmental variable influencing stream yields for both total N and total P. Models 2, 3 and 4 did not identify any watershed environmental variables that could adequately explain the observed variability in the nitrate yields among the set of sites examined by each of these models. The results for Models 2, 3, and 4 indicated that watersheds with higher percentages of forested land had lower annual total N and total P yields compared to watersheds with lower percentages of forested land, which had higher median annual total N and total P yields. Additional environmental variables determined to further influence the stream nutrient yields included median annual percentage of point-source flow contributions to the streams, variables of land cover (percentage of forested land, agricultural land, and (or) forested land plus wetlands) in the watershed and (or) in the stream buffer, and drainage area. The regression tree models can serve as a tool for relating differences in select watershed attributes to differences in stream yields of nitrate, total N, and total P, which can provide beneficial information for improving nutrient management in streams throughout North Carolina and for reducing nutrient loads to coastal waters.
2013-05-20
territorial and resource disputes, violent extremism, natural disasters , proliferation, illicit trafficking and more. This complex security...killed by natural disasters annually. Those figures represent 90% and 65% of the world totals, respectively.” 32 The benefits of having two operational...demand …We train to a 5 full range of missions, from humanitarian assistance and disaster relief, to maritime security operations, to amphibious
Oregon Intellectual Freedom Clearinghouse Annual Report. May 1987-June 30, 1988.
ERIC Educational Resources Information Center
Oregon State Library, Salem. Intellectual Freedom Clearinghouse.
Established in May 1987 by the Oregon State Library to serve as a central clearinghouse for the collection of reports about challenges against library materials, the Oregon Intellectual Freedom Clearinghouse received a total of 17 formal challenges against library materials during its first year of operation. Of these, 10 challenges were received…
76 FR 34124 - Notice of Passenger Facility Charge (PFC) Approvals and Disapprovals
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-10
... International Airport. Brief Description Of Projects Approved for Collection and Use at a $4.50 PFC Level...- demand air operations that enplane less than 2,500 passengers per year at Portland International Airport... less than 1 percent of the total annual enplanements at Los Angeles International Airport. Brief...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-02
... the Office of Management and Budget (OMB) for review and approval. Written comments and/or suggestions... methodology and assumptions used; (3) The quality, utility, and clarity of the information to be collected.... There are capital, operating, and/or maintenance costs of $98,022. The total estimated annualized burden...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-06
..., you should comment and provide your total capital and startup cost components or annual operation... cost factors, including system and technology acquisition, expected useful life of capital equipment, discount rate(s), and the period over which you incur costs. Capital and startup costs include, among other...
Jobs Analysis | Energy Analysis | NREL
manufacturing analysis-focuses on jobs creation and economic output at the national, state, and community levels economic development and activity through investment in solar and wind projects. Featured Study In Economic construction period and 350 jobs annually during 20-year operation Total economic impact over 20-year life
50 CFR 665.252 - Harvest limitation program.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Grounds for Permit Area 1 will be set annually for the calendar year and shall: (1) Apply to the total... the overall harvest guideline for Crustacean Permit Area 1 will be reached; (ii) Closure date after... Permit Area 1 is prohibited by any permitted vessel that is not operating a VMS unit certified by NMFS...
50 CFR 665.252 - Harvest limitation program.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Grounds for Permit Area 1 will be set annually for the calendar year and shall: (1) Apply to the total... the overall harvest guideline for Crustacean Permit Area 1 will be reached; (ii) Closure date after... Permit Area 1 is prohibited by any permitted vessel that is not operating a VMS unit certified by NMFS...
50 CFR 665.252 - Harvest limitation program.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Grounds for Permit Area 1 will be set annually for the calendar year and shall: (1) Apply to the total... the overall harvest guideline for Crustacean Permit Area 1 will be reached; (ii) Closure date after... Permit Area 1 is prohibited by any permitted vessel that is not operating a VMS unit certified by NMFS...
Staffing for Unmanned Aircraft Systems (UAS) Operations
2016-06-01
Service’s staffing determination . Using these business rules and observations enabled the follow-on assessment of individual UAS mission elements... Determination Framework ......................................................13 B. Inherently Governmental (IG...authorities, and the determination of inherently governmental (IG) activities. Table 1. Delta between Rank/Pay Grades Annual Total Cost O-4 O-3 W-3 W-2
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-04
... collection techniques or other forms of information technology; and (e) ways to further reduce the... Informational Tariffs, and 64.710 Operator Services for Prison Inmate Phones. Total Annual Burden: 205,023 hours... informational tariffs with the Commission. These rules help to ensure that consumers receive information...
Corporation for Public Broadcasting Annual Report, 1971.
ERIC Educational Resources Information Center
Corporation for Public Broadcasting, Washington, DC.
The Corporation for Public Broadcasting (CPB) continued to grow in fiscal year 1971, its third year of operation. Fourteen new public television stations began broadcasting, bringing 7.9 million more persons within receiving range, and bringing the total number of TV stations to 207. Income increased 18 per cent to $14 million due largely to more…
Economics of installation of solar heating plants
NASA Astrophysics Data System (ADS)
Popel, O. S.; Frid, S. Y.; Shpiltayn, E. E.
1984-04-01
An engineering-economic analysis of solar heating plants for determination of their cost effectiveness involves calculating the maximum economically feasibile extra capital investment on their installation and calculating the fraction of the total heat demand covered by such a plant which makes replacement of conventional heating plant maximally economical. The annual economic effect of solar heating is calculated in terms of normalized cost differential, as criterion for its competitiveness with conventional heating. Plant performance characteristics, namely dependence of both the percent demand coverage and the annual cost differential on the area of solar radiation collectors is then considered. Analysis of the cost equation, assuming that the extra fixed cost is proportional to the collector area, reveals the necessary and sufficient condition for decrease of annual operating cost.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-23
... information regarding these corrections and removals and to determine whether recall action is adequate... Annual Reporting Burden\\1\\ Annual 21 CFR section Number of frequency per Total annual Hours per Total... Average Annual Recordkeeping Burden \\1\\ Annual 21 CFR Section Number of frequency per Total annual Hours...
Orywal, Ann Kathrin; Knipper, Ann Sophie; Tiburtius, Christian; Gross, Andreas J; Netsch, Christopher
2015-12-01
To evaluate trends in efficacy and safety of flexible ureteroscopy (fURS) for the treatment of lower pole stones (LPS) over a 6-year period and to compare the annual outcomes after one fURS procedure retrospectively. Four hundred nine patients were treated for pure LPS. An analysis of the annual outcomes regarding patient characteristics, operative parameters, stone-free rates (SFRs), and complication rates (CRs) was performed. The SFR was stratified according to stone size and number of stones per patient. Patient data are expressed as mean±standard deviation. There were no annual differences regarding age, body-mass index, stone size (7.09±4.31 mm), number of stones per patient (1.66±2.86), operative time (52.93±33.58 minutes), use of postoperative stents (59.2%), and the Ho:YAG laser lithotripsy rate (49.4%) during the 6-year period. Total primary SFR (annual range) of 97.6% (88.2%-100%), 89.1% (82.9%-96.3%), 71% (60%-78.6%) for urinary calculi <5 mm (3.43±0.78 mm), 5-9 mm (6.69±1.34 mm), and ≥10 mm (13.09±6.02 mm) could be demonstrated over the 6-year period. The total SFR differed significantly between urinary calculi <5 mm, 5-9 mm, and those ≥10 mm (p<0.0179). The SFR (annual range) decreased from 90% (86.2%-95.4%) in patients with 1 stone to 84.1% (60%-100%) in those with ≥3 stones. Perioperative complications (annual range) occurred in 9.7% (6%-13.6%) of the patients (Clavien I 5.1% [1.2%-8.6%], Clavien II 2% [0%-4.9%], Clavien IIIa 0.9% [0%-3.4%], Clavien IIIb 1.7% [1.2%-4.8%]) without differences in the annual CR. fURS is a safe and efficacious procedure for the treatment of LPS with high primary SFR and low CR. fURS in larger LPS (≥10 mm) is associated with the risk for staged procedures.
Code of Federal Regulations, 2010 CFR
2010-01-01
... consumption, estimated annual operating cost, and energy efficiency rating, and of water use rate. 305.5... energy efficiency rating, and of water use rate. (a) Procedures for determining the estimated annual energy consumption, the estimated annual operating costs, the energy efficiency ratings, and the efficacy...
Demonstration of the feasibility of automated silicon solar cell fabrication
NASA Technical Reports Server (NTRS)
Thornhill, J. W.; Taylor, W. E.
1976-01-01
An analysis of estimated costs indicate that for an annual output of 4,747,000 hexagonal cells (38 mm. on a side) a total factory cost of $0.866 per cell could be achieved. For cells with 14% efficiency at AMO intensity (1353 watts per square meter), this annual production rate is equivalent to 3,373 kilowatts and a manufacturing cost of $1.22 per watt of electrical output. A laboratory model of such a facility was operated to produce a series of demonstration runs, producing hexagonal cells, 2 x 2 cm cells and 2 x 4 cm cells.
Total number of longwall faces drops below 50
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fiscor, S.
2009-02-15
For the first time since Coal Age began its annual Longwall Census the number of faces has dropped below 50. A total of five mines operate two longwall faces. CONSOL Energy remains the leader with 12 faces. Arch Coal operates five longwall mines; Robert E. Murray owns five longwall mines. West Virginia has 13 longwalls, followed by Pennsylvania (8), Utah (6) and Alabama (6). A detailed table gives for each longwall installation, the ownership, seam height, cutting height, panel width and length, overburden, number of gate entries, depth of cut, model of equipment used (shearer, haulage system, roof support, facemore » conveyor, stage loader, crusher, electrical controls and voltage to face). 2 tabs., 1 photo.« less
Maroney, Justin; Khan, Saba; Powell, Wayne; Klein, Lloyd W
2013-01-01
We seek to assess the per-operator volume of diagnostic catheterizations and percutaneous coronary interventions (PCI) among US cardiologists, and its implication for future manpower needs in the catheterization laboratory. The number of annual Medicare PCIs peaked in 2004 and has trended downward since, however the total number of catheterization laboratories nationwide has increased. It is unknown whether these trends have resulted in a dilution of per-operator volumes, and whether the current supply of interventional cardiologists is appropriate to meet future needs. We analyzed the Centers for Medicare and Medicaid Services 2008 Medicare 5% sample file, and extracted the total number of Medicare fee-for-service (Medicare FFS) diagnostic catheterizations and PCIs performed in 2008. We then determined per-physician procedure volumes using National Provider Identifier numbers. There were 1,198,610 Medicare FFS diagnostic catheterizations performed by 11,029 diagnostic cardiologists, and there were 378,372 Medicare FFS PCIs performed by 6,443 interventional cardiologists in 2008. The data reveal a marked difference in the 2008 distribution of diagnostic catheterizations and PCIs among operators. Just over 10% of diagnostic catheterizations were performed by operators performing 40 or fewer Medicare FFS diagnostic catheterizations, contrasted with almost 30% of PCIs performed by operators with 40 of fewer Medicare FFS PCIs. A significant majority of interventional cardiologists (61%) performed 40 or fewer Medicare FFS PCIs in 2008. There is a high percentage of low-volume operators performing PCI, raising questions regarding annual volume recommendations for procedural skill maintenance, and the future manpower requirements in the catheterization laboratory. Copyright © 2012 Wiley Periodicals, Inc.
75 FR 30030 - Agency Information Collection Activities: Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-28
... Governments; Number of Respondents: 51; Total Annual Responses: 51; Total Annual Hours: 102. (For policy... dialysis facilities are required to report. Form Number: CMS-265-94 (OMB : 0938-0236); Frequency: Yearly...,508; Total Annual Responses: 5,508; Total Annual Hours: 275,400. (For policy questions regarding this...
Code of Federal Regulations, 2010 CFR
2010-07-01
... further air quality review, the lessee shall use the highest annual-total amount of emissions from the... MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER... quality of an onshore area. To make these decisions, the Regional Supervisor shall consider the distance...
ERIC Educational Resources Information Center
Hackett, E. Raymond; Morgan, Thomas
1996-01-01
Examines strategies for conducting expected and deferred maintenance of small colleges for use as a model that may be adapted to other educational settings. Investigates the relationship between total education and general expenditures and expenditures for operation of plant and maintenance, and looks at using the annual budget to meet expected…
State of Hawaii Department of Education Financial Report, July 1, 2003-June 30, 2004.
ERIC Educational Resources Information Center
State of Hawaii Department of Education, 2005
2005-01-01
This annual financial report of the Department of Education is prepared each year to inform interested persons of the total cost of public education in the state of Hawaii. The financial report provides both Operating and Capital Improvement Project fund information that is useful in presenting our educational system financing, expenditures and…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-29
... chartered FCUs: Respondents/record-keepers: 2 per year. Estimated annual burden: 20 hours. Total annual... application. Total annual hours: 365,334. ICR: Membership denial. Respondents/record-keepers: 1055 [[frac14.../record-keepers: All FCUs (4,220). Estimated annual burden: 1 hour. Total annual hours: 4,220. Article V...
Fischer, Sebastian; Meyer, Georg; Kramer, Axel
2012-01-01
In preparation for implementation of a central water processing system at a dental department, we analyzed the costs of conventional decentralized disinfection of dental units against a central water treatment concept based on electrochemical disinfection. The cost evaluation included only the costs of annually required antimicrobial consumables and additional water usage of a decentralize conventional maintenance system for dental water lines build in the respective dental units and the central electrochemical water disinfection system, BLUE SAFETY™ Technologies. In total, analysis of costs of 6 dental departments reviled additional annual costs for hygienic preventive measures of € 4,448.37. For the BLUE SAFETY™ Technology, the additional annual total agent consumption costs were € 2.18, accounting for approximately 0.05% of the annual total agent consumption costs of the conventional maintenance system. For both water processing concepts, the additional costs for energy could not be calculated, since the required data was not obtainable from the manufacturers. For both concepts, the investment and maintenance costs were not calculated due to lack of manufacturer's data. Therefore, the results indicate the difference of costs for the required consumables only. Aside of the significantly lower annual costs for required consumables and disinfectants; a second advantage for the BLUE SAFETY™ Technology is its constant and automatic operation, which does not require additional staff resources. This not only safety human resources, but add additionally to cost saving. Since the antimicrobial disinfection capacity of the BLUE SAFETY™ was demonstrated previously and is well known, this technology, which is comparable or even superior in its non-corrosive effect, may be regarded as method of choice for continuous disinfection and prevention of biofilm formation in dental units' water lines.
Fischer, Sebastian; Meyer, Georg; Kramer, Axel
2012-01-01
Background: In preparation for implementation of a central water processing system at a dental department, we analyzed the costs of conventional decentralized disinfection of dental units against a central water treatment concept based on electrochemical disinfection. Methods: The cost evaluation included only the costs of annually required antimicrobial consumables and additional water usage of a decentralize conventional maintenance system for dental water lines build in the respective dental units and the central electrochemical water disinfection system, BLUE SAFETY™ Technologies. Results: In total, analysis of costs of 6 dental departments reviled additional annual costs for hygienic preventive measures of € 4,448.37. For the BLUE SAFETY™ Technology, the additional annual total agent consumption costs were € 2.18, accounting for approximately 0.05% of the annual total agent consumption costs of the conventional maintenance system. For both water processing concepts, the additional costs for energy could not be calculated, since the required data was not obtainable from the manufacturers. Discussion: For both concepts, the investment and maintenance costs were not calculated due to lack of manufacturer's data. Therefore, the results indicate the difference of costs for the required consumables only. Aside of the significantly lower annual costs for required consumables and disinfectants; a second advantage for the BLUE SAFETY™ Technology is its constant and automatic operation, which does not require additional staff resources. This not only safety human resources, but add additionally to cost saving. Conclusion: Since the antimicrobial disinfection capacity of the BLUE SAFETY™ was demonstrated previously and is well known, this technology, which is comparable or even superior in its non-corrosive effect, may be regarded as method of choice for continuous disinfection and prevention of biofilm formation in dental units’ water lines. PMID:22558042
Rainfall and evapotranspiration data for southwest Medina County, Texas, August 2006-December 2009
Slattery, Richard N.; Asquith, William H.; Ockerman, Darwin J.
2011-01-01
During August 2006-December 2009, the U.S. Geological Survey (USGS), in cooperation with the U.S. Army Corps of Engineers, Fort Worth District, collected rainfall and evapotranspiration data to help characterize the hydrology of the Nueces River Basin, Texas. The USGS installed and operated a station to collect continuous (30-minute interval) rainfall and evapotranspiration data in southwest Medina County approximately 14 miles southwest of D'Hanis, Texas, and 23 miles northwest of Pearsall, Texas. Rainfall data were collected by using an 8-inch tipping bucket raingage. Meteorological and surface-energy flux data used to calculate evapotranspiration were collected by using an extended Open Path Eddy Covariance system from Campbell Scientific, Inc. Data recorded by the system were used to calculate evapotranspiration by using the eddy covariance and Bowen ratio closure methods and to analyze the surface energy budget closure. During August 2006-December 2009 (excluding days of missing record), measured rainfall totaled 86.85 inches. In 2007, 2008, and 2009, annual rainfall totaled 40.98, 12.35, and 27.15 inches, respectively. The largest monthly rainfall total, 12.30 inches, occurred in July 2007. During August 2006-December 2009, evapotranspiration calculated by using the eddy covariance method totaled 69.91 inches. Annual evapotranspiration calculated by using the eddy covariance method totaled 34.62 inches in 2007, 15.24 inches in 2008, and 15.57 inches in 2009. During August 2006-December 2009, evapotranspiration calculated by using the Bowen ratio closure method (the more refined of the two datasets) totaled 68.33 inches. Annual evapotranspiration calculated by using the Bowen ratio closure method totaled 32.49, 15.54, and 15.80 inches in 2007, 2008, and 2009, respectively (excluding days of missing record).
Payne, W. Vance
2017-01-01
A 2715 ft2 (252 m2), two story, residential home of the style typical of the Gaithersburg, Maryland area was constructed in 2012 to demonstrate technologies for net-zero energy (NZE) homes (or ZEH). The NIST Net-Zero Energy Residential Test Facility (NZERTF) functions as a laboratory to support the development and adoption of cost-effective NZE designs, technologies, construction methods, and building codes. The primary design goal was to meet the comfort and functional needs of the simulated occupants. The first annual test period began on July 1, 2013 and ended June 30, 2014. During the first year of operation, the home's annual energy consumption was 13039 kWh (4.8 kWh ft-2, 51.7 kWh m-2), and the 10.2 kW solar photovoltaic system generated an excess of 484 kWh. During this period the heating and air conditioning of the home was performed by a novel air-source heat pump that utilized a reheat heat exchanger to allow hot compressor discharge gas to reheat the supply air during a dedicated dehumidification mode. During dedicated dehumidification, room temperature air was supplied to the living space until the relative humidity setpoint of 50% was satisfied. The heat pump consumed a total of 6225 kWh (2.3 kWh ft-2, 24.7 kWh m-2) of electrical energy for cooling, heating, and dehumidification. Annual cooling efficiency was 10.1 Btu W-1h-1 (2.95 W W-1), relative to the rated SEER of the heat pump of 15.8 Btu W-1h-1 (4.63 W W-1). Annual heating efficiency was 7.10 Btu W-1h-1 (2.09 W W-1), compared with the unit's rated HSPF of 9.05 Btu W-1h-1 (2.65 W W-1). These field measured efficiency numbers include dedicated dehumidification operation and standby energy use for the year. Annual sensible heat ratio was approximately 70%. Standby energy consumption was 5.2 % and 3.5 % of the total electrical energy used for cooling and heating, respectively. PMID:28729740
Payne, W Vance
2016-01-01
A 2715 ft 2 (252 m 2 ), two story, residential home of the style typical of the Gaithersburg, Maryland area was constructed in 2012 to demonstrate technologies for net-zero energy (NZE) homes (or ZEH). The NIST Net-Zero Energy Residential Test Facility (NZERTF) functions as a laboratory to support the development and adoption of cost-effective NZE designs, technologies, construction methods, and building codes. The primary design goal was to meet the comfort and functional needs of the simulated occupants. The first annual test period began on July 1, 2013 and ended June 30, 2014. During the first year of operation, the home's annual energy consumption was 13039 kWh (4.8 kWh ft -2 , 51.7 kWh m -2 ), and the 10.2 kW solar photovoltaic system generated an excess of 484 kWh. During this period the heating and air conditioning of the home was performed by a novel air-source heat pump that utilized a reheat heat exchanger to allow hot compressor discharge gas to reheat the supply air during a dedicated dehumidification mode. During dedicated dehumidification, room temperature air was supplied to the living space until the relative humidity setpoint of 50% was satisfied. The heat pump consumed a total of 6225 kWh (2.3 kWh ft -2, 24.7 kWh m -2 ) of electrical energy for cooling, heating, and dehumidification. Annual cooling efficiency was 10.1 Btu W -1 h -1 (2.95 W W -1 ), relative to the rated SEER of the heat pump of 15.8 Btu W -1 h -1 (4.63 W W -1 ). Annual heating efficiency was 7.10 Btu W -1 h -1 (2.09 W W -1 ), compared with the unit's rated HSPF of 9.05 Btu W -1 h -1 (2.65 W W -1 ). These field measured efficiency numbers include dedicated dehumidification operation and standby energy use for the year. Annual sensible heat ratio was approximately 70%. Standby energy consumption was 5.2 % and 3.5 % of the total electrical energy used for cooling and heating, respectively.
Designing adaptive operating rules for a large multi-purpose reservoir
NASA Astrophysics Data System (ADS)
Geressu, Robel; Rougé, Charles; Harou, Julien
2017-04-01
Reservoirs whose live storage capacity is large compared with annual inflow have "memory", i.e., their storage levels contain information about past inflows and reservoir operations. Such "long-memory" reservoirs can be found in basins in dry regions such as the Nile River Basin in Africa, the Colorado River Basin in the US, or river basins in Western and Central Asia. There the effects of a dry year have the potential to impact reservoir levels and downstream releases for several subsequent years, prompting tensions in transboundary basins. Yet, current reservoir operation rules in those reservoirs do not reflect this by integrating past climate history and release decisions among the factors that influence operating decisions. This work proposes and demonstrates an adaptive reservoir operating rule that explicitly accounts for the recent history of release decisions, and not only current storage level and near-term inflow forecasts. This implies adding long-term (e.g., multiyear) objectives to the existing short-term (e.g., annual) ones. We apply these operating rules to the Grand Ethiopian Renaissance Dam, a large reservoir under construction on the Blue Nile River. Energy generation has to be balanced with the imperative of releasing enough water in low flow years (e.g., the minimum 1, 2 or 3 year cumulative flow) to avoid tensions with downstream countries, Sudan and Egypt. Maximizing the minimum multi-year releases could be of interest for the Nile problem to minimize the impact on performance of the large High Aswan Dam in Egypt. Objectives include maximizing the average and minimum annual energy generation and maximizing the minimum annual, two year and three year cumulative releases. The system model is tested using 30 stochastically generated streamflow series. One can then derive adaptive release rules depending on the value of one- and two-year total releases with respect to thresholds. Then, there are 3 sets of release rules for the reservoir depending on whether one or both thresholds are not met, vs. only one with a non-adaptive rule. Multi-objective evolutionary algorithms (MOEAs) are used to obtain the Pareto front, i.e., non-dominated adaptive and non-adaptive operating rule sets. Implementing adaptive rules is found to improve the trade-offs between energy generation criteria and minimum release targets. Compared with non-adaptive operations, an adaptive operating policy shows an increase of around 3 and 10 Billion cubic meters in the minimum 1 and 3-year cumulative releases for a given value of the same average annual energy generation.
Oregon Intellectual Freedom Clearinghouse. Second Annual Report, July 1, 1988-June 30, 1989.
ERIC Educational Resources Information Center
Oregon State Library, Salem. Intellectual Freedom Clearinghouse.
Challenges against library materials that were reported to the Oregon Intellectual Freedom Clearinghouse by Oregon libraries during its second full year of operation totalled 34 books, 13 of which were owned by public libraries and 21 by school libraries. The first challenge against an art exhibit in a public library was also reported. In 25 of…
A novel design of reactive distillation configuration for 2-methoxy-2-methylheptane process
NASA Astrophysics Data System (ADS)
Hussain, Arif; Qyyum, Muhammad Abdul; Quang Minh, Le; Jimin, Hong; Lee, Moonyong
2017-11-01
The study aims to reveal the possibility of reactive distillation (RD) in the 2-methoxy-2-methylheptane (MMH) production process. MMH is getting more industrial and academic interests as a gasoline additive to replace methyl tert-butyl ether. Traditionally, MMH is obtained by carrying out the reaction in the reactor followed by three distillation columns. The high yield of MMH could be achieved by keeping the large reactor size or by using the large excess of 2-methyl-1-heptene (MH). Both former and latter strategies are associated with the high capital and operating costs. To solve these problems, this study proposed an innovative RD configuration to take synergistic benefits of reaction and separation involved. This innovative RD configuration allows the production of MMH with significantly lower capital, operating and total annual costs. For desired MMH yield, the result demonstrates that the proposed RD configuration can reduce energy, capital, and total annual costs up to 7.7, 31.3, and 17.1%, respectively, compared to a conventional process. Furthermore, the influence of some important design parameters on the RD column performance was also explored to overcome the temperature limitation of acid resin catalyst inside the reactive zone of the RD column.
STARPAHC Interim Evaluation Report, May 1975 - April 1976
NASA Technical Reports Server (NTRS)
1976-01-01
The primary goals of the STARPAHC Program are to provide data for developing health care for future manned spacecraft, and to establish the feasibility of the STARPAHC concept for improving the delivery of health care to remote areas on earth. Accordingly, the hardware and medical evaluations initiated during the first 6 months of system operation were continued and expanded during the second 6-month period. The evaluations are based on what has proven to be a relatively stabilized 6-month period wherein system failures which occurred during the initial shakedown period in the first 6 months have been minimized. Early trends and performance data reported in the first semi-annual report were reexamined to either verify, modify or change earlier conclusions. The highlights are given of the total year of operation with emphasis on comparisons between the first and second semi-annual reporting period. In addition, an early analysis of costs is summarized.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chapman, J.
1994-07-01
This is one of a series of reports that document the steps taken to plan and install a utility-scale windfarm and follow its energy production performance. The reports are intended to help utility planners and others better understand the issues involved in installing and operating a windfarm. This report describes the Zond Victory Garden Phase IV (VGIV) windfarm in the Tehachapi mountain region, 100 miles north of Los Angeles. The Victory Garden series of windfarms were planned and installed and are operated by Zond Systems, Inc. of Tehachapi, California. The VGIV installation, which became operational in stages from January throughmore » June 1990, consists of 98 Vestas V27--225 wind turbines. The total rated capacity is 22 MW with a projected annual average net energy production of 54.3 million kWh/yr, equivalent to an annual capacity factor of 0.28. This energy projection, based on extensive wind resource measurements and an average wind turbine availability of 97%, includes the effects of a number of operational loss factors. The report includes descriptions of the windfarm layout, the wind turbine component, and the electrical layout. Particular attention is paid to one of the most important issues in implementing a windfarm, namely, the wind resource assessment and its use in projecting and updating the expected annual-average energy production of the facility. Also included are details of the planning, construction, and commissioning of the windfarm along with a description of the operations and maintenance procedures employed.« less
Code of Federal Regulations, 2012 CFR
2012-04-01
... Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER IRRIGATION OPERATION AND...) Annual operation and maintenance assessment rates may be lowered through the exercise of our discretion... supplemental water is available, the calculation of your annual operation and maintenance assessment rate may...
Code of Federal Regulations, 2013 CFR
2013-04-01
... Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER IRRIGATION OPERATION AND...) Annual operation and maintenance assessment rates may be lowered through the exercise of our discretion... supplemental water is available, the calculation of your annual operation and maintenance assessment rate may...
Code of Federal Regulations, 2014 CFR
2014-04-01
... Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER IRRIGATION OPERATION AND...) Annual operation and maintenance assessment rates may be lowered through the exercise of our discretion... supplemental water is available, the calculation of your annual operation and maintenance assessment rate may...
SABRE: Dark matter annual modulation detection in the northern and southern hemispheres
NASA Astrophysics Data System (ADS)
Tomei, C.
2017-02-01
SABRE (Sodium-iodide with Active Background REjection) is a new NaI(Tl) experiment designed to search for galactic Dark Matter through the annual modulation signature. SABRE will consist of highly pure NaI(Tl) crystals operated in an active liquid scintillator veto. The SABRE experiment will follow a two-phase approach. In the first phase, one high-purity NaI(Tl) crystal will be operated at LNGS in an active liquid scintillator veto with the goal of demonstrating backgrounds low enough for a sensitive test of the DAMA/LIBRA result. An unprecedented radio-purity for both the NaI powder and the crystal growth will be needed to achieve this goal. The second phase will consist in building two high-purity NaI(Tl) detector arrays, with a total mass of about 50 kg each, located at LNGS and in the Stawell Gold Mine in Australia. The operation of twin full-scale experiments in both the northern and the southern hemispheres will strengthen the reliability of the result against any possible seasonal systematic effect.
Stewart, Barclay; Wong, Evan; Papillon-Smith, Jessica; Trelles Centurion, Miguel Antonio; Dominguez, Lynette; Ao, Supongmeren; Jean-Paul, Basimuoneye Kahutsi; Kamal, Mustafa; Helmand, Rahmatullah; Naseer, Aamer; Kushner, Adam L
2015-03-27
Surgical capacity assessments in low-income countries have demonstrated critical deficiencies. Though vital for planning capacity improvements, these assessments are resource intensive and impractical during the planning phase of a humanitarian crisis. This study aimed to determine cesarean sections to total operations performed (CSR) and emergency herniorrhaphies to all herniorrhaphies performed (EHR) ratios from Médecins Sans Frontières Operations Centre Brussels (MSF-OCB) projects and examine if these established metrics are useful proxies for surgical capacity in low-income countries affected by crisis. All procedures performed in MSF-OCB operating theatres from July 2008 through June 2014 were reviewed. Projects providing only specialty care, not fully operational or not offering elective surgeries were excluded. Annual CSRs and EHRs were calculated for each project. Their relationship was assessed with linear regression. After applying the exclusion criteria, there were 47,472 cases performed at 13 sites in 8 countries. There were 13,939 CS performed (29% of total cases). Of the 4,632 herniorrhaphies performed (10% of total cases), 30% were emergency procedures. CSRs ranged from 0.06 to 0.65 and EHRs ranged from 0.03 to 1.0. Linear regression of annual ratios at each project did not demonstrate statistical evidence for the CSR to predict EHR [F(2,30)=2.34, p=0.11, R2=0.11]. The regression equation was: EHR = 0.25 + 0.52(CSR) + 0.10(reason for MSF-OCB assistance). Surgical humanitarian assistance projects operate in areas with critical surgical capacity deficiencies that are further disrupted by crisis. Rapid, accurate assessments of surgical capacity are necessary to plan cost- and clinically-effective humanitarian responses to baseline and acute unmet surgical needs in LICs affected by crisis. Though CSR and EHR may meet these criteria in 'steady-state' healthcare systems, they may not be useful during humanitarian emergencies. Further study of the relationship between direct surgical capacity improvements and these ratios is necessary to document their role in humanitarian settings.
Stewart, Barclay; Wong, Evan; Papillon-Smith, Jessica; Trelles Centurion, Miguel Antonio; Dominguez, Lynette; Ao, Supongmeren; Jean-Paul, Basimuoneye Kahutsi; Kamal, Mustafa; Helmand, Rahmatullah; Naseer, Aamer; Kushner, Adam L.
2015-01-01
Background: Surgical capacity assessments in low-income countries have demonstrated critical deficiencies. Though vital for planning capacity improvements, these assessments are resource intensive and impractical during the planning phase of a humanitarian crisis. This study aimed to determine cesarean sections to total operations performed (CSR) and emergency herniorrhaphies to all herniorrhaphies performed (EHR) ratios from Médecins Sans Frontières Operations Centre Brussels (MSF-OCB) projects and examine if these established metrics are useful proxies for surgical capacity in low-income countries affected by crisis. Methods: All procedures performed in MSF-OCB operating theatres from July 2008 through June 2014 were reviewed. Projects providing only specialty care, not fully operational or not offering elective surgeries were excluded. Annual CSRs and EHRs were calculated for each project. Their relationship was assessed with linear regression. Results: After applying the exclusion criteria, there were 47,472 cases performed at 13 sites in 8 countries. There were 13,939 CS performed (29% of total cases). Of the 4,632 herniorrhaphies performed (10% of total cases), 30% were emergency procedures. CSRs ranged from 0.06 to 0.65 and EHRs ranged from 0.03 to 1.0. Linear regression of annual ratios at each project did not demonstrate statistical evidence for the CSR to predict EHR [F(2,30)=2.34, p=0.11, R2=0.11]. The regression equation was: EHR = 0.25 + 0.52(CSR) + 0.10(reason for MSF-OCB assistance). Conclusion: Surgical humanitarian assistance projects operate in areas with critical surgical capacity deficiencies that are further disrupted by crisis. Rapid, accurate assessments of surgical capacity are necessary to plan cost- and clinically-effective humanitarian responses to baseline and acute unmet surgical needs in LICs affected by crisis. Though CSR and EHR may meet these criteria in ‘steady-state’ healthcare systems, they may not be useful during humanitarian emergencies. Further study of the relationship between direct surgical capacity improvements and these ratios is necessary to document their role in humanitarian settings. PMID:25905025
Expert consensus of general surgery residents' proficiency with common endocrine operations.
Phitayakorn, Roy; Kelz, Rachel R; Petrusa, Emil; Sippel, Rebecca S; Sturgeon, Cord; Patel, Kepal N; Perrier, Nancy D
2017-01-01
Proficiency with common endocrine operations is expected of graduating, general surgery residents. However, no expert consensus guidelines exist about these expectations. Members of the American Association of Endocrine Surgeons were surveyed about their opinions on resident proficiency with common endocrine operations. Overall response rate was 38%. A total of 92% of the respondents operate with residents. On average, they believed that the steps of a total thyroidectomy for benign disease and a well-localized parathyroidectomy could be performed by a postgraduate year 4 surgery resident. Specific steps that they thought might require more training included decisions to divide the strap muscles or leaving a drain. Approximately 66% of respondents thought that a postgraduate year 5 surgery resident could independently perform a total thyroidectomy for benign disease, but only 45% felt similarly for malignant thyroid disease; 79% thought that a postgraduate year 5 surgery resident could independently perform a parathyroidectomy. Respondents' years of experience correlated with their opinions about resident autonomy for total thyroidectomy (benign r = 0.38, P < .001; malignant r = 0.29, P = .001) but not parathyroidectomy. On multivariate analysis, sex and years of experience of the respondents were independently associated with opinions on autonomy but only for total thyroidectomy for benign disease (P = .001). Annual endocrine volume of the respondents did not correlate with beliefs in autonomy. There was general agreement among responding members of the AAES about resident proficiency and autonomy with common endocrine operations. As postgraduate year 5 residents may not be proficient in advanced endocrine operations, opportunities exist to improve training prior to the transition to independent practice for graduates that anticipate performing endocrine operations routinely. Copyright © 2016 Elsevier Inc. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-24
.... Estimated Annualized Burden Hours and Costs Number of Avg. burden Total Total Number of responses Total per annual Avg. annual Type of respondent Form name/ form No. respondents per number of response burden (in...
14 CFR 120.119 - Annual reports.
Code of Federal Regulations, 2011 CFR
2011-01-01
... AND OPERATORS FOR COMPENSATION OR HIRE: CERTIFICATION AND OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Drug Testing Program Requirements § 120.119 Annual reports. (a) Annual reports of testing results must... holder shall submit an annual report each year. (2) Each entity conducting a drug testing program under...
14 CFR 120.119 - Annual reports.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND OPERATORS FOR COMPENSATION OR HIRE: CERTIFICATION AND OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Drug Testing Program Requirements § 120.119 Annual reports. (a) Annual reports of testing results must... holder shall submit an annual report each year. (2) Each entity conducting a drug testing program under...
14 CFR 120.119 - Annual reports.
Code of Federal Regulations, 2012 CFR
2012-01-01
... AND OPERATORS FOR COMPENSATION OR HIRE: CERTIFICATION AND OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Drug Testing Program Requirements § 120.119 Annual reports. (a) Annual reports of testing results must... holder shall submit an annual report each year. (2) Each entity conducting a drug testing program under...
14 CFR 120.119 - Annual reports.
Code of Federal Regulations, 2013 CFR
2013-01-01
... AND OPERATORS FOR COMPENSATION OR HIRE: CERTIFICATION AND OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Drug Testing Program Requirements § 120.119 Annual reports. (a) Annual reports of testing results must... holder shall submit an annual report each year. (2) Each entity conducting a drug testing program under...
14 CFR 120.119 - Annual reports.
Code of Federal Regulations, 2014 CFR
2014-01-01
... AND OPERATORS FOR COMPENSATION OR HIRE: CERTIFICATION AND OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Drug Testing Program Requirements § 120.119 Annual reports. (a) Annual reports of testing results must... holder shall submit an annual report each year. (2) Each entity conducting a drug testing program under...
Rodríguez Bolaños, Rosibel de Los Ángeles; Reynales Shigematsu, Luz Myriam; Jiménez Ruíz, Jorge Alberto; Juárez Márquezy, Sergio Arturo; Hernández Ávila, Mauricio
2010-12-01
Estimate the direct cost of medical care incurred by the Mexican Social Security Institute (IMSS, Instituto Mexicano del Seguro Social) for patients with type 2 diabetes mellitus (DM2). The clinical files of 497 patients who were treated in secondary and tertiary medical care units in 2002-2004 were reviewed. Costs were quantified using a disease costing approach (DCA) from the provider's perspective, a micro-costing technique, and a bottom-up methodology. Average annual costs by diagnosis, complication, and total cost were estimated. Total IMSS DM2 annual costs were US$452 064 988, or 3.1% of operating expenses. The annual average cost per patient was US$3 193.75, with US$2 740.34 per patient without complications and US$3 550.17 per patient with complications. Hospitalization and intensive care bed-days generated the greatest expenses. The high cost of providing medical care to patients with DM2 and its complications represents an economic burden that health institutions should consider in their budgets to enable them to offer quality service that is both adequate and timely. Using the micro-costing methodology allows an approximation to real data on utilization and management of the disease.
Sulfur dioxide emissions from combustion in china: from 1990 to 2007.
Su, Shenshen; Li, Bengang; Cui, Siyu; Tao, Shu
2011-10-01
China has become the world's largest emitter of SO(2) since 2005, and aggressive deployment of flue gas desulfurization (FGD) at coal-fired power plants appeared in China when facing the formidable pressure of environment pollution. In this work, we estimate the annual emission from combustion sources at provincial levels in China from 1990 to 2007, with updated data investigations. We have implemented the method of transportation matrix to gain a better understanding of sulfur content of coal in consuming provinces, which in turn improved the inventory. The total emissions from combustion in 2007 were 28.3 Tg, half of which was contributed by coal-fired power plants. Meanwhile, the industrial boiler coal combustion and residential coal consumed in centralized heating were responsible for another 32% of the total emissions. From 1990 to 2007, annual SO(2) emission was fluctuated with two peaks (1996 and 2006), and total emission doubled from 15.4 Tg to 30.8 Tg, at an annual growth rate of 4.4% (6.3% since 2000). Due to the extensive application of FGD technology and the phase-out of small, high emitting units, the SO(2) emission began to decrease after 2006. Furthermore, the differences among estimates reported in literatures highlight a great need for further research to reduce the uncertainties with more detailed information on key sources and actual operation of devices.
Annual Review of Aircraft Accident Data. US Carrier Operations Calendar Year 1997
2002-01-24
its surveys of general aviation activity. National Transportation Safety Board Report Form 6120.4 (appendix F) shows the data elements upon which this...Beginning with the 1998 Annual Reviews, the Safety Board will present annual statistics for commercial and general aviation in a revised format. The...Operation N135 = Nonscheduled 14 CFR 135 Operation S121 = Scheduled 14 CFR 121 Operation Forgn = Foreign Registered Aircraft Operation GA = General
Energy conservation through sealing technology
NASA Technical Reports Server (NTRS)
Stair, W. K.; Ludwig, L. P.
1978-01-01
Improvements in fluid film sealing resulting from a proposed research program could lead to an annual energy saving, on a national basis, equivalent to about 37 million bbl of oil or 0.3% of the total U.S. energy consumption. Further, the application of known sealing technology can result in an annual saving of an additional 10 million bbl of oil. The energy saving would be accomplished by reduction in process heat energy loss, reduction of frictional energy generated, and minimization of energy required to operate ancillary equipment associated with the seal system. In addition to energy saving, cost effectiveness is further enhanced by reduction in maintenance and in minimization of equipment for collecting leakage and for meeting environmental pollution standards.
Water treatment plants assessment at Talkha power plant.
El-Sebaie, Olfat D; Abd El-Kerim, Ghazy E; Ramadan, Mohamed H; Abd El-Atey, Magda M; Taha, Sahr Ahmed
2002-01-01
Talkha power plant is the only power plant located in El-Mansoura. It generates electricity using two different methods by steam turbine and gas turbine. Both plants drew water from River Nile (208 m3 /h). The Nile raw water passes through different treatment processes to be suitable for drinking and operational uses. At Talkha power plant, there are two purification plants used for drinking water supply (100 m3/h) and for water demineralization supply (108 m3/h). This study aimed at studying the efficiency of the water purification plants. For drinking water purification plant, the annual River Nile water characterized by slightly alkaline pH (7.4-8), high annual mean values of turbidity (10.06 NTU), Standard Plate Count (SPC) (313.3 CFU/1 ml), total coliform (2717/100 ml), fecal coliform (0-2400/100 ml), and total algae (3 x 10(4) org/I). The dominant group of algae all over the study period was green algae. The blue green algae was abundant in Summer and Autumn seasons. The pH range, and the annual mean values of turbidity, TDS, total hardness, sulfates, chlorides, nitrates, nitrites, fluoride, and residual chlorine for purified water were in compliance with Egyptian drinking water standards. All the SPC recorded values with an annual mean value of 10.13 CFU/1 ml indicated that chlorine dose and contact time were not enough to kill the bacteria. However, they were in compliance with Egyptian decree (should not exceed 50 CFU/1 ml). Although the removal efficiency of the plant for total coliform and blue green algae was high (98.5% and 99.2%, respectively), the limits of the obtained results with an annual mean values of 40/100 ml and 15.6 org/l were not in compliance with the Egyptian decree (should be free from total coliform, fecal coliform and blue green algae). For water demineralization treatment plant, the raw water was characterized by slightly alkaline pH. The annual mean values of conductivity, turbidity, and TDS were 354.6 microS/cm, 10.84 NTU, and 214.6 mg/I, respectively. There was an increase in the results of conductivity, turbidity, total hardness, and TDS in carbon filter effluent which was attributed to the desorption of adsorbed ions on the carbon media. The removal efficiencies of turbidity, total hardness, and TDS indicated the high efficiency of the cationic filter. The annual removal efficiencies of conductivity, turbidity, chloride, and TDS proved the efficiency of the anionic filter for removing the dissolved and suspended ions. All of the recorded values of the pH, conductivity, turbidity, chlorides, hardness, and TDS of the mixed bed effluent indicated that the water at this stage was of high quality for boiler feed. The study recommended adjustment of coagulant and residual chlorine doses as well as contact time, and continuous monitoring and maintenance of the different units.
78 FR 56995 - Proposed Agency Information Collection Activities; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-16
...: Businesses. Respondent Universe: 763 railroads. Frequency of Submission: On occasion. Reporting Burden Total annual Average time per Total annual CFR Section Respondent universe responses response burden hours 225... Universe: 763 railroads. Frequency of Submission: On occasion; annually. Reporting Burden Respondent Total...
NASA Technical Reports Server (NTRS)
Cecil, Daniel J.; Buechler, Dennis E.; Blakeslee, Richard J.
2015-01-01
The Tropical Rainfall Measuring Mission (TRMM) Lightning Imaging Sensor (LIS) has been collecting observations of total lightning in the global tropics and subtropics (roughly 38 deg S - 38 deg N) since December 1997. A similar instrument, the Optical Transient Detector, operated from 1995-2000 on another low earth orbit satellite that also saw high latitudes. Lightning data from these instruments have been used to create gridded climatologies and time series of lightning flash rate. These include a 0.5 deg resolution global annual climatology, and lower resolution products describing the annual cycle and the diurnal cycle. These products are updated annually. Results from the update through 2013 will be shown at the conference. The gridded products are publicly available for download. Descriptions of how each product can be used will be discussed, including strengths, weaknesses, and caveats about the smoothing and sampling used in various products.
75 FR 63889 - Proposed Agency Information Collection Activities; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-18
...: Railroads. Respondent Universe: Class I Railroads. Frequency of Submission: On occasion. Average time per Total annual Total annual CFR Section Respondent universe Total annual responses response burden hours.... Form Number(s): N/A. Affected Public: Railroads. Respondent Universe: 685 railroads/ 4 locomotive...
78 FR 18672 - Proposed Agency Information Collection Activities; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-27
... monitoring regulatory compliance. Form Number(s): N/A. Affected Public: Businesses. Respondent Universe: 728 railroads. Frequency of Submission: On occasion. Average time CFR section Respondent universe Total annual... time CFR section Respondent universe Total annual per response Total annual responses (minutes) burden...
Sosa, Julie Ann; Hanna, John W; Robinson, Karen A; Lanman, Richard B
2013-12-01
To provide population-based estimates of trends in thyroid nodule fine-needle aspirations (FNA) and operative volumes, we used multiple claims databases to quantify rates of these procedures and their association with the increasing incidence of thyroid cancer in the United States. Private and public insurance claims databases were used to estimate procedure volumes from 2006 to 2011. Rates of FNA and thyroid operations related to thyroid nodules were defined by CPT4 codes associated with International Classification of Diseases, Ninth Revision Clinical Modification codes for nontoxic uni- or multinodular goiter and thyroid neoplasms. Use of thyroid FNA more than doubled during the 5-year study period (16% annual growth). The number of thyroid operations performed for thyroid nodules increased by 31%. Total thyroidectomies increased by 12% per year, whereas lobectomies increased only 1% per year. In 2011, total thyroidectomies accounted for more than half (56%) of the operations for thyroid neoplasms in the United States. Thyroid operations became increasingly (62%) outpatient procedures. Thyroid FNA and operative procedures have increased rapidly in the United States, with an associated increase in the incidence of thyroid cancer. The more substantial increase in number of total versus partial thyroid resections suggests that patients undergoing thyroid operation are perceived to have a greater risk of cancer as determined by preoperative assessments, but this trend could also increase detection of incidental microcarcinomas. Copyright © 2013 Mosby, Inc. All rights reserved.
Weaver, J. Curtis
2006-01-01
A study of annual maximum precipitation frequency in Mecklenburg County, North Carolina, was conducted to characterize the frequency of precipitation at sites having at least 10 years of precipitation record. Precipitation-frequency studies provide information about the occurrence of precipitation amounts for given durations (for example, 1 hour or 24 hours) that can be expected to occur within a specified recurrence interval (expressed in years). In this study, annual maximum precipitation totals were determined for durations of 15 and 30 minutes; 1, 2, 3, 6, 12, and 24 hours; and for recurrence intervals of 2, 5, 10, 25, 50, 100, and 500 years. Precipitation data collected by the U.S. Geological Survey network of raingages in the city of Charlotte and Mecklenburg County were analyzed for this study. In September 2004, more than 70 precipitation sites were in operation; 27 of these sites had at least 10 years of record, which is the minimum record typically required in frequency studies. Missing record at one site, however, resulted in its removal from the dataset. Two datasets--the Charlotte Raingage Network (CRN) initial and CRN modified datasets--were developed from the U.S. Geological Survey data, which represented relatively short periods of record (10 and 11 years). The CRN initial dataset included very high precipitation totals from two storms that caused severe flooding in areas of the city and county in August 1995 and July 1997, which could significantly influence the statistical results. The CRN modified dataset excluded the highest precipitation totals from these two storms but included the second highest totals. More...
Implementation plan for Bolivian Mineral Exploration Fund
Kirkemo, Harold
1978-01-01
Bolivia ranks second among world producers of tin and antimony, and first in bismuth production. Mineral exports in 1975 were valued at $314.2 million, nearly 60 percent of the value of all exports, and petroleum product exports totalled nearly $157 million, or 30 percent of the total. Tin accounted for 58 percent of the total value of metallic mineral exports. The central government derived about 19 percent of its total tax revenues in 1975 from the mining sector. The mining sector consists of the large, medium, and small mining subsectors, a classification established by the government. Individual operations are referred to as large, medium, or small depending upon the subsector into which they are classified. All large mining enterprises are owned and operated by a government corporation, COMIBOL; the medium and small operations are privately owned. COMIBOL's exports in 1975 were valued at $171.8 million or 70 percent of the total mineral exports; the medium mines accounted for $55.5 million or 23 percent, and the small mines for $17.5 million or 7 percent of the total. The combination of high operating costs, low productivity, inadequate ore reserves, and insufficient risk capital for exploration and development has led to the realization that there is an urgent need to improve the situation for mining in Bolivia. Proposals are being studied to revise the tax code, a program is underway to evaluate selected mineral deposits for possible exploration and development, and programs are under consideration to encourage minerals exploration. A minerals exploration plan is proposed which would offer technical and financial aid to various segments in the minerals field. A program, estimated to cost between $2 million and $2.5 million annually, and to be operated by a new agency in the Ministry of Mining and Metallurgy, is outlined.
Torikai, J.D.
1995-01-01
This report contains hydrologic and climatic data that describe the status of ground-water resources at U.S. Navy Support Facility, Diego Garcia. Data are presented from January 1992 through September 1994. This report concentrates on data from July through September 1994, and references historic data from 1992 through June 1994. Total rainfall for the first nine months of 1994 was about 77 inches which is 72 percent of the mean annual rainfall of 106 inches. In comparison, total rainfall for the first nine months of 1992 and 1993 was 67 inches and 69 inches, respectively. Annual rainfall totals in 1992 and 1993 were 93 inches and 95 inches, respectively. Ground-water withdrawal during July through September 1994 has averaged 919,400 gallons per day, while annual withdrawals in 1992 and 1993 averaged 935,900 gallons per day and 953,800 gallons per day, respectively. At the end of September 1994, the chloride concentration of the composite water supply was 56 milligrams per liter, well below the 250 milligrams per liter secondary drinking-water standard established by the U.S. Environmental Protection Agency. Chloride concentrations of the composite water supply from July through September 1994 ranged between 51 and 78 milligrams per liter. Chloride concentration of ground water in monitoring wells at Cantonment and Air Operations increased in July and August, but have leveled off or decreased in September. There has been a general trend of increasing chloride concentrations in the deeper monitoring wells since the 1992 dry season, which began in March 1992. A fuel leak at Air Operations caused the shutdown of ten wells in May 1991. Four of the wells resumed pumping for water-supply purposes in April 1992. The remaining six wells are being used to hydraulically contain and divert fuel migration by recirculating 150,000 gallons of water each day.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The Western Area Power Administration (Western) has established a formal environmental protection, auditing, monitoring, and planning program that has been in effect since 1978. The significant environmental projects and issues Western was involved with in 1995 are discussed in this annual site environmental report. It is written to show the nature and effectiveness of the environmental protection program. Western operates and maintains nearly 17,000 miles of transmission lines, 257 substations, and various appurtenant power facilities in fifteen central and western states. Western is also responsible for planning, construction, and operation and maintenance of additional federal transmission facilities that may bemore » authorized in the future. There is a combined total of 55 hydroelectric power generating plants in the service area. Additionally, Western markets the US entitlement from the Navajo coal-fired plant near Page, Arizona. The Department of Energy requires the preparation of an annual site environmental report. Because Western has over 400 facilities located in these states, this report addresses the environmental activities in all the facilities as one site.« less
Walla Walla River Fish Passage Operations Program, 2003-2004 Annual Report.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bronson, James P.
2004-12-01
In the late 1990s, the Confederated Tribes of the Umatilla Indian Reservation, Oregon Department of Fish and Wildlife, and Washington Department of Fish and Wildlife, along with many other agencies, began implementing fisheries restoration activities in the Walla Walla Basin. An integral part of these efforts is to alleviate the inadequate fish migration conditions in the basin. The migration concerns are being addressed by removing diversion structures, constructing fish passage facilities, implementing minimum instream flow requirements, and providing trap and haul efforts when needed. The objective of the Walla Walla River Fish Passage Operations Project is to increase the survivalmore » of migrating adult and juvenile salmonids in the Walla Walla River basin. The project is responsible for coordinating operation and maintenance of ladders, screen sites, bypasses, trap facilities, and transportation equipment. In addition, the project provides technical input on passage criteria and passage and trapping facility design and operation. Operation of the various passage facilities and passage criteria guidelines are outlined in an annual operations plan that the project develops. During the 2003-2004 project year, there were 379 adult summer steelhead (Oncorhynchus mykiss), 36 adult bull trout (Salvelinus confluentus); 108 adult and 3 jack spring chinook (O. tshawytscha) enumerated at the Nursery Bridge Dam fishway video counting window between December 21, 2003, and June 30, 2004. Summer steelhead and spring chinook were observed moving upstream while bull trout were observed moving both upstream and downstream of the facility. In addition, the old ladder trap was operated by the WWBNPME project in order to radio tag spring chinook adults. A total of 2 adult summer steelhead, 4 bull trout, and 23 adult spring chinook were enumerated at the west ladder at Nursery Bridge Dam during the trapping operations between May 6 and May 23, 2004. Operation of the Little Walla Walla River juvenile trap for trap and haul purposes was not necessary this year. The project transported adult spring chinook from Threemile Dam to the South Fork Walla Walla Brood Holding Facility. A total of 239 spring chinook were outplanted in August for natural spawning in the basin.« less
Han, Wei; Hu, Yun Yi; Li, Shi Yi; Li, Fei Fei; Tang, Jun Hong
2016-12-01
Biohydrogen production from waste bread in a continuous stirred tank reactor (CSTR) was techno-economically assessed. The treating capacity of the H 2 -producing plant was assumed to be 2 ton waste bread per day with lifetime of 10years. Aspen Plus was used to simulate the mass and energy balance of the plant. The total capital investment (TCI), total annual production cost (TAPC) and annual revenue of the plant were USD931020, USD299746/year and USD639920/year, respectively. The unit hydrogen production cost was USD1.34/m 3 H 2 (or USD14.89/kg H 2 ). The payback period and net present value (NPV) of the plant were 4.8years and USD1266654, respectively. Hydrogen price and operators cost were the most important variables on the NPV. It was concluded that biohydrogen production from waste bread in the CSTR was feasible for practical application. Copyright © 2016 Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-22
... for how long they will need to keep working, their financial goals for retirement, the basis for... information. OMB Number: 1210-NEW. Respondents: 2,950. Number of Annual Responses: 2,950. Total Burden Hours: 945 hours. Total Annualized Capital/Startup Costs: $0. Total Annual Costs: $244,800. Description: The...
Mupondwa, Edmund; Li, Xue; Boyetchko, Susan; Hynes, Russell; Geissler, Jon
2015-01-01
The study presents an ex ante technoeconomic analysis of commercial production of Pseudomonas fluorescens BRG100 bioherbicide in Canada. An engineering economic model is designed in SuperPro Designer® to investigate capital investment scaling and profitability. Total capital investment for a stand-alone BRG100 fermentation plant at baseline capacity (two 33,000L fermenters; 3602tonnesannum(-1)) is $17.55million. Total annual operating cost is $14.76million. Raw materials account for 50% of operating cost. The fermentation plant is profitable over wide operating scale, evaluated over a range of BRG100 prices and costs of capital. Smaller plants require higher NPV breakeven prices. However, larger plants are more sensitive to changes in the cost of capital. Unit production costs decrease as plant capacity increases, indicating scale economies. A plant operating for less than one year approaches positive NPV for periods as low as 2months. These findings can support bioherbicide R&D investment and commercialization strategies. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 1,000 hours of operation or annually, whichever comes first;1 b. Inspect air cleaner every 1,000 hours of operation or annually, whichever comes first, and replace as necessary; c. Inspect all hoses and belts every 500 hours of operation or annually, whichever comes first, and replace as necessary...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 1,000 hours of operation or annually, whichever comes first;1 b. Inspect air cleaner every 1,000 hours of operation or annually, whichever comes first, and replace as necessary; c. Inspect all hoses and belts every 500 hours of operation or annually, whichever comes first, and replace as necessary...
Development of a Variable-Speed Residential Air-Source Integrated Heat Pump
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rice, C Keith; Shen, Bo; Munk, Jeffrey D
2014-01-01
A residential air-source integrated heat pump (AS-IHP) is under development in partnership with a U.S. manufacturer. A nominal 10.6 kW (3-ton) cooling capacity variable-speed unit, the system provides both space conditioning and water heating. This multi-functional unit can provide domestic water heating (DWH) in either full condensing (FC) (dedicated water heating or simultaneous space cooling and water heating) or desuperheating (DS) operation modes. Laboratory test data were used to calibrate a vapor-compression simulation model for each mode of operation. The model was used to optimize the internal control options for efficiency while maintaining acceptable comfort conditions and refrigerant-side pressures andmore » temperatures within allowable operating envelopes. Annual simulations were performed with the AS-IHP installed in a well-insulated house in five U.S. climate zones. The AS-IHP is predicted to use 45 to 60% less energy than a DOE minimum efficiency baseline system while meeting total annual space conditioning and water heating loads. Water heating energy use is lowered by 60 to 75% in cold to warmer climates, respectively. Plans are to field test the unit in Knoxville, TN.« less
Process water reduction in a wire milling operation. 1989 summer intern report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alberg, J.
1989-12-31
Johnson Filtration Systems is a company located in New Brighton, Minnesota which employs 256 people. The focus of the project was to reduce the water usage of the wire milling operation. Water in the milling process is used to clean the wire and cool the mill components. Total annual water usage for this operation is six million gallons. The milling process changes the cross sectional shape of the wire by using flattening hammers and rollers. A synthetic coolant is used to enhance this process and remove heat. The coolant is removed from the wire as it is pulled through amore » squeegee, washed it with water and dried with an air knife.« less
Code of Federal Regulations, 2012 CFR
2012-07-01
... 1,000 hours of operation or annually, whichever comes first; 1 Minimize the engine's time spent at... apply. b. Inspect air cleaner every 1,000 hours of operation or annually, whichever comes first;c. Inspect all hoses and belts every 500 hours of operation or annually, whichever comes first, and replace...
Cost Analysis of Establishing a Relationship Between a Surgical Program in the US and Vietnam
Chu, Quyen D.; Nguyen, Thu; Nguyen, Phuong; Ho, Hung S.
2012-01-01
“Twinning” refers to a constructive partnership between hospitals in developed and developing nations. Such an effort may contribute immensely to capacity building for the developing nation, but one of the reasons given for the lack of sustainability is cost. We share a detailed operating cost analysis of our recent experience with an institution in Vietnam. We were awarded a 1-year $54,000 grant from the Vietnam Education Foundation (VEF) to conduct a live tele-video conferencing course on the “Fundamentals of Clinical Surgery” with Thai Binh Medical University (TBMU). In-country lectures as well as an assessment of the needs at TBMU were performed. Total financial assistance and expenditures were tabulated to assess up-front infrastructure investment and annual cost required to sustain the program. The total amount of direct money ($66,686) and in-kind services ($70,276) was $136,962. The initial infrastructure cost was $41,085, which represented 62% of the direct money received. The annual cost to sustain the program was approximately $11,948. We concluded that the annual cost to maintain a “twinning” program was relatively low, and the efforts to sustain a “twinning” program were financially feasible and worthwhile endeavors. “Twinning” should be a critical part of the surgical humanitarian volunteerism effort. PMID:23102082
Cost analysis of establishing a relationship between a surgical program in the US and Vietnam.
Chu, Quyen D; Nguyen, Thu; Nguyen, Phuong; Ho, Hung S
2012-01-01
"Twinning" refers to a constructive partnership between hospitals in developed and developing nations. Such an effort may contribute immensely to capacity building for the developing nation, but one of the reasons given for the lack of sustainability is cost. We share a detailed operating cost analysis of our recent experience with an institution in Vietnam. We were awarded a 1-year $54,000 grant from the Vietnam Education Foundation (VEF) to conduct a live tele-video conferencing course on the "Fundamentals of Clinical Surgery" with Thai Binh Medical University (TBMU). In-country lectures as well as an assessment of the needs at TBMU were performed. Total financial assistance and expenditures were tabulated to assess up-front infrastructure investment and annual cost required to sustain the program. The total amount of direct money ($66,686) and in-kind services ($70,276) was $136,962. The initial infrastructure cost was $41,085, which represented 62% of the direct money received. The annual cost to sustain the program was approximately $11,948. We concluded that the annual cost to maintain a "twinning" program was relatively low, and the efforts to sustain a "twinning" program were financially feasible and worthwhile endeavors. "Twinning" should be a critical part of the surgical humanitarian volunteerism effort.
Operative needs in HIV+ populations: An estimation for sub-Saharan Africa.
Cherewick, Megan L; Cherewick, Steven D; Kushner, Adam L
2017-05-01
In 2015, it was estimated that approximately 36.7 million people were living with HIV globally and approximately 25.5 million of those people were living in sub-Saharan Africa. Limitations in the availability and access to adequate operative care require policy and planning to enhance operative capacity. Data estimating the total number of persons living with HIV by country, sex, and age group were obtained from the Joint United Nations Programme on HIV/AIDS (UNAIDS) in 2015. Using minimum proposed surgical rates per 100,000 for 4, defined, sub-Saharan regions of Africa, country-specific and regional estimates were calculated. The total need and unmet need for operative procedures were estimated. A minimum of 1,539,138 operative procedures were needed in 2015 for the 25.5 million persons living with HIV in sub-Saharan Africa. In 2015, there was an unmet need of 908,513 operative cases in sub-Saharan Africa with the greatest unmet need in eastern sub-Saharan Africa (427,820) and western sub-Saharan Africa (325,026). Approximately 55.6% of the total need for operative cases is adult women, 38.4% are adult men, and 6.0% are among children under the age of 15. A minimum of 1.5 million operative procedures annually are required to meet the needs of persons living with HIV in sub-Saharan Africa. The unmet need for operative care is greatest in eastern and western sub-Saharan Africa and will require investments in personnel, infrastructure, facilities, supplies, and equipment. We highlight the need for global planning and investment in resources to meet targets of operative capacity. Copyright © 2016 Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 12 Banks and Banking 3 2014-01-01 2014-01-01 false Total Annual Loan Cost Rate Computations for Reverse Mortgage Transactions K Appendix K to Part 226 Banks and Banking FEDERAL RESERVE SYSTEM (CONTINUED..., App. K Appendix K to Part 226—Total Annual Loan Cost Rate Computations for Reverse Mortgage...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 12 Banks and Banking 3 2013-01-01 2013-01-01 false Total Annual Loan Cost Rate Computations for Reverse Mortgage Transactions K Appendix K to Part 226 Banks and Banking FEDERAL RESERVE SYSTEM (CONTINUED..., App. K Appendix K to Part 226—Total Annual Loan Cost Rate Computations for Reverse Mortgage...
Buck, Stephanie D.
2014-01-01
The Poteau Valley Improvement Authority uses Wister Lake in southeastern Oklahoma as a public water supply. Total phosphorus, total nitrogen, and suspended sediments from agricultural runoff and discharges from wastewater treatment plants and other sources have degraded water quality in the lake. As lake-water quality has degraded, water-treatment cost, chemical usage, and sludge production have increased for the Poteau Valley Improvement Authority. The U.S. Geological Survey (USGS), in cooperation with the Poteau Valley Improvement Authority, investigated and summarized concentrations of total phosphorus, total nitrogen, suspended sediment, and bacteria (Escherichia coli and Enterococcus sp.) in surface water flowing to Wister Lake. Estimates of total phosphorus, total nitrogen, and suspended sediment loads, yields, and flow-weighted mean concentrations of total phosphorus and total nitrogen concentrations were made for the Wister Lake Basin for a 3-year period from October 2010 through September 2013. Data from water samples collected at fixed time increments during base-flow conditions and during runoff conditions at the Poteau River at Loving, Okla. (USGS station 07247015), the Poteau River near Heavener, Okla. (USGS station 07247350), and the Fourche Maline near Leflore, Okla. (USGS station 07247650), water-quality stations were used to evaluate water quality over the range of streamflows in the basin. These data also were collected to estimate annual constituent loads and yields by using regression models. At the Poteau River stations, total phosphorus, total nitrogen, and suspended sediment concentrations in surface-water samples were significantly larger in samples collected during runoff conditions than in samples collected during base-flow conditions. At the Fourche Maline station, in contrast, concentrations of these constituents in water samples collected during runoff conditions were not significantly larger than concentrations during base-flow conditions. Flow-weighted mean total phosphorus concentrations at all three stations from 2011 to 2013 were several times larger than the Oklahoma State Standard for Scenic Rivers (0.037 milligrams per liter [mg/L]), with the largest flow-weighted phosphorus concentrations typically being measured at the Poteau River at Loving, Okla., station. Flow-weighted mean total nitrogen concentrations did not vary substantially between the Poteau River stations and the Fourche Maline near Leflore, Okla., station. At all of the sampled water-quality stations, bacteria (Escherichia coli and Enterococcus sp.) concentrations were substantially larger in water samples collected during runoff conditions than in water samples collected during base-flow conditions from 2011 to 2013. Estimated annual loads of total phosphorus, total nitrogen, and suspended sediment in the Poteau River stations during runoff conditions ranged from 82 to 98 percent of the total annual loads of those constituents. Estimated annual loads of total phosphorus, total nitrogen, and suspended sediment in the Fourche Maline during runoff conditions ranged from 86 to nearly 100 percent of the total annual loads. Estimated seasonal total phosphorus loads generally were smallest during base-flow and runoff conditions in autumn. Estimated seasonal total phosphorus loads during base-flow conditions tended to be largest in winter and during runoff conditions tended to be largest in the spring. Estimated seasonal total nitrogen loads tended to be smallest in autumn during base-flow and runoff conditions and largest in winter during runoff conditions. Estimated seasonal suspended sediment loads tended to be smallest during base-flow conditions in the summer and smallest during runoff conditions in the autumn. The largest estimated seasonal suspended sediment loads during runoff conditions typically were in the spring. The estimated mean annual total phosphorus yield was largest at the Poteau River at Loving, Okla., water-quality station. The estimated mean annual total phosphorus yield was largest during base flow at the Poteau River at Loving, Okla., water-quality station and at both of the Poteau River water-quality stations during runoff conditions. The estimated mean annual total nitrogen yields were largest at the Poteau River water-quality stations. Estimated mean annual total nitrogen yields were largest during base-flow and runoff conditions at the Poteau River at Loving, Okla., water-quality station. The estimated mean annual suspended sediment yield was largest at the Poteau River near Heavener, Okla., water-quality station during base-flow and runoff conditions. Flow-weighted mean concentrations indicated that total phosphorus inputs from the Poteau River Basin in the Wister Lake Basin were larger than from the Fourche Maline Basin. Flow-weighted mean concentrations of total nitrogen did not vary spatially in a consistent manner. The Poteau River and the Fourche Maline contributed estimated annual total phosphorus loads of 137 to 278 tons per year (tons/yr) to Wister Lake. Between 89 and 95 percent of the annual total phosphorus loads were transported to Wister Lake during runoff conditions. The Poteau River and the Fourche Maline contributed estimated annual total nitrogen loads of 657 to 1,294 tons/yr, with 86 to 94 percent of the annual total nitrogen loads being transported to Wister Lake during runoff conditions. The Poteau River and the Fourche Maline contributed estimated annual total suspended sediment loads of 110,919 to 234,637 tons/yr, with 94 to 99 percent of the annual suspended sediment loads being transported to Wister Lake during runoff conditions. Most of the total phosphorus and suspended sediment were delivered to Wister Lake during runoff conditions in the spring. The majority of the total nitrogen was delivered to Wister Lake during runoff conditions in winter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... stationary CI RICE. 1 a. Change oil and filter every 500 hours of operation or annually, whichever comes first; 2 b. Inspect air cleaner every 1,000 hours of operation or annually, whichever comes first; c. Inspect all hoses and belts every 500 hours of operation or annually, whichever comes first, and replace...
49 CFR 220.11 - Requirements for roadway workers.
Code of Federal Regulations, 2011 CFR
2011-10-01
... more annual employee work hours: (1) Maintenance-of-way equipment operating without locomotive.... A railroad with fewer than 400,000 annual employee work hours may provide immediate access to...: (1) Railroads which have fewer than 400,000 annual employee work hours, and which do not operate...
49 CFR 220.11 - Requirements for roadway workers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... more annual employee work hours: (1) Maintenance-of-way equipment operating without locomotive.... A railroad with fewer than 400,000 annual employee work hours may provide immediate access to...: (1) Railroads which have fewer than 400,000 annual employee work hours, and which do not operate...
Hoekman, Daniël R; Rutten, Juliette M T M; Vlieger, Arine M; Benninga, Marc A; Dijkgraaf, Marcel G W
2015-11-01
To estimate annual medical and nonmedical costs of care for children diagnosed with irritable bowel syndrome (IBS) or functional abdominal pain (syndrome; FAP/FAPS). Baseline data from children with IBS or FAP/FAPS who were included in a multicenter trial (NTR2725) in The Netherlands were analyzed. Patients' parents completed a questionnaire concerning usage of healthcare resources, travel costs, out-of-pocket expenses, productivity loss of parents, and supportive measures at school. Use of abdominal pain related prescription medication was derived from case reports forms. Total annual costs per patient were calculated as the sum of direct and indirect medical and nonmedical costs. Costs of initial diagnostic investigations were not included. A total of 258 children, mean age 13.4 years (±5.5), were included, and 183 (70.9%) were female. Total annual costs per patient were estimated to be €2512.31. Inpatient and outpatient healthcare use were major cost drivers, accounting for 22.5% and 35.2% of total annual costs, respectively. Parental productivity loss accounted for 22.2% of total annual costs. No difference was found in total costs between children with IBS or FAP/FAPS. Pediatric abdominal pain related functional gastrointestinal disorders impose a large economic burden on patients' families and healthcare systems. More than one-half of total annual costs of IBS and FAP/FAPS consist of inpatient and outpatient healthcare use. Netherlands Trial Registry: NTR2725. Copyright © 2015 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Chuck; Scofield, Ben; Pavlik, Deanne
2003-03-01
A slightly dryer than normal year yielded flows in Lake Roosevelt that were essentially equal to the past ten year average. Annual mean inflow and outflow were 3,160.3 m3/s and 3,063.4 m3/s respectively. Mean reservoir elevation was 387.2 m above sea level at the Grand Coulee Dam forebay. The forebay elevation was below the mean elevation for a total of 168 days. During the first half of the 2000 forebay elevation changed at a rate of 0.121 m/d and during the last half changed at a rate of 0.208 m/d. The higher rate of elevation change earlier in the yearmore » is due to the drawdown to accommodate spring runoff. Mean annual water retention time was 40 days. Annual mean total dissolved gas was 108%. Total dissolved gas was greatest at upriver locations (110% = US/Canada Border annual mean) and decreased moving toward Grand Coulee Dam (106% = Grand Coulee Dam Forebay annual mean). Total dissolved gas was greatest in May (122% reservoir wide monthly mean). Gas bubble trauma was observed in 16 fish primarily largescale suckers and was low in severity. Reservoir wide mean temperatures were greatest in August (19.5 C) and lowest in January (5.5 C). The Spokane River and Sanpoil River Arms experienced higher temperatures than the mainstem reservoir. Brief stratification was observed at the Sanpoil River shore location in July. Warm water temperatures in the Spokane Arm contributed to low dissolved oxygen concentrations in August (2.6 mg/L at 33 m). However, decomposition of summer algal biomass was likely the main cause of depressed dissolved oxygen concentrations. Otherwise, dissolved oxygen profiles were relatively uniform throughout the water column across other sampling locations. Annual mean Secchi depth throughout the reservoir was 5.7 m. Nutrient concentrations were generally low, however, annual mean total phosphorus (0.016 mg/L) was in the mesotrophic range. Annual mean total nitrogen was in the meso-oligotrophic range. Total nitrogen to total phosphorus ratios were large (31:1 annual mean) likely indicating phosphorus limitations to phytoplankton.« less
Joint Space Operations Center (JSpOC) Mission System Increment 2 (JMS Inc 2)
2016-03-01
Defense Acquisition Executive DoD - Department of Defense DoDAF - DoD Architecture Framework FD - Full Deployment FDD - Full Deployment Decision FY...date has slipped from September 2016 to December 2016 and FDD has slipped from October 2016 to March 2017 since the last MAIS Annual Report...testing. This added test time, in combination with funding reductions and the US Government furlough and shutdown in FY13, caused a total FDD slip
DOT National Transportation Integrated Search
1984-12-01
This report summarizes the financial and operating data submitted annually to the Urban Mass Transportation Administration (UMTA) by the nation's public transit operators, pursuant to Section 15 of the Urban Mass Transportation (UMT) Act of 1964, as ...
Ground-based microwave radiometry to determine stratospheric and mesospheric ozone profiles
NASA Astrophysics Data System (ADS)
Lobsiger, E.
1987-05-01
From April 1984 to April 1985 a microwave radiometer was operated at Bern measuring the thermal emission of the rotational ozone transition at 142.2 GHz to determine stratospheric and mesospheric ozone abundances in the range 25-75 km altitude. From a total of 334 retrieved daytime profiles, monthly mean ozone partial pressures for Umkehr layers 6-10 were calculated. On this basis ozone variations compare favorably with Umkehr data from the nearby Arosa station and with a monthly zonal mean model compiled from satellite data by Keating and Young (1985). From the microwave data, an annual mean ozone distribution was determined. The method retrieves somewhat larger ozone volume mixing ratios between 25 and 30 km altitude. For the rest of the measurement range of the sensor there is good agreement with 20-year annual mean ozone values from Arosa, with the Krueger and Minzner profile and with the respective annual mean data given by Keating and Young.
Outcomes of PCI in Relation to Procedural Characteristics and Operator Volumes in the United States.
Fanaroff, Alexander C; Zakroysky, Pearl; Dai, David; Wojdyla, Daniel; Sherwood, Matthew W; Roe, Matthew T; Wang, Tracy Y; Peterson, Eric D; Gurm, Hitinder S; Cohen, Mauricio G; Messenger, John C; Rao, Sunil V
2017-06-20
Professional guidelines have reduced the recommended minimum number to an average of 50 percutaneous coronary intervention (PCI) procedures performed annually by each operator. Operator volume patterns and associated outcomes since this change are unknown. The authors describe herein PCI operator procedure volumes; characteristics of low-, intermediate-, and high-volume operators; and the relationship between operator volume and clinical outcomes in a large, contemporary, nationwide sample. Using data from the National Cardiovascular Data Registry collected between July 1, 2009, and March 31, 2015, we examined operator annual PCI volume. We divided operators into low- (<50 PCIs per year), intermediate- (50 to 100 PCIs per year), and high- (>100 PCIs per year) volume groups, and determined the adjusted association between annual PCI volume and in-hospital outcomes, including mortality. The median annual number of procedures performed per operator was 59; 44% of operators performed <50 PCI procedures per year. Low-volume operators more frequently performed emergency and primary PCI procedures and practiced at hospitals with lower annual PCI volumes. Unadjusted in-hospital mortality was 1.86% for low-volume operators, 1.73% for intermediate-volume operators, and 1.48% for high-volume operators. The adjusted risk of in-hospital mortality was higher for PCI procedures performed by low- and intermediate-volume operators compared with those performed by high-volume operators (adjusted odds ratio: 1.16 for low versus high; adjusted odds ratio: 1.05 for intermediate vs. high volume) as was the risk for new dialysis post PCI. No volume relationship was observed for post-PCI bleeding. Many PCI operators in the United States are performing fewer than the recommended number of PCI procedures annually. Although absolute risk differences are small and may be partially explained by unmeasured differences in case mix between operators, there remains an inverse relationship between PCI operator volume and in-hospital mortality that persisted in risk-adjusted analyses. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 12 Banks and Banking 8 2012-01-01 2012-01-01 false Total Annual Loan Cost Rate Computations for Reverse Mortgage Transactions K Appendix K to Part 1026 Banks and Banking BUREAU OF CONSUMER FINANCIAL PROTECTION TRUTH IN LENDING (REGULATION Z) Pt. 1026, App. K Appendix K to Part 1026—Total Annual Loan Cost...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 12 Banks and Banking 8 2013-01-01 2013-01-01 false Total Annual Loan Cost Rate Computations for Reverse Mortgage Transactions K Appendix K to Part 1026 Banks and Banking BUREAU OF CONSUMER FINANCIAL PROTECTION TRUTH IN LENDING (REGULATION Z) Pt. 1026, App. K Appendix K to Part 1026—Total Annual Loan Cost...
Prospective Evaluation of Operating Room Inefficiency.
Madni, Tarik D; Imran, Jonathan B; Clark, Audra T; Cunningham, Holly B; Taveras, Luis; Arnoldo, Brett D; Phelan, Herb A; Wolf, Steven E
2018-04-06
Previously, we identified that 60% of our facility's total operative time is nonoperative. We performed a review of our operating room to determine where inefficiencies exist in nonoperative time. Live video of operations performed in a burn operating room from 6/23/17 to 8/16/17 were prospectively reviewed. Preparation (end of induction to procedure start) and turnover (patient out of room to next patient in room) were divided into the following activities: 1) Preparation: remove dressing, position patient, clean patient, drape patient, and 2) Turnover: clean operating room, scrub tray set-up, anesthesia set-up. Ideal preparation time was calculated as the sum of time needed to perform preparation activities consecutively. Ideal turnover time was calculated as the sum of time needed to clean the operating room and to set up either the scrub tray or anesthesia (the larger of the two times as these can be done in parallel). We reviewed 101 consecutive operations. An average of 2.4±0.8 cases/day were performed. Ideal preparation and turnover time were 16.6 and 30.1 minutes, a 38.3% and 32.5% reduction compared to actual times. Attending surgeon presence in the operating room within 10 minutes of a patient's arrival was found to significantly decrease time to incision by 33% (52.7±14.3 minutes down to 35.7±20.4, p<0.0001). A reduction in preparation and turnover time could save $1.02 million and generate $1.76 million in additional revenue annually. Reducing preparation and turnover to ideal times could increase caseload to 4/day, leading to millions of dollars of savings annually.
Modelling erosion on a daily basis, an adaptation of the MMF approach
NASA Astrophysics Data System (ADS)
Shrestha, Dhruba Pikha; Jetten, Victor G.
2018-02-01
Effect of soil erosion causing negative impact on ecosystem services and food security is well known. On the other hand there can be yearly variation of total precipitation received in an area, with the presence of extreme rains. To assess annual erosion rates various empirical models have been extensively used in all the climatic regions. While these models are simple to operate and do not require lot of input data, the effect of extreme rain is not taken into account. Although physically based models are available to simulate erosion processes including particle detachment, transportation and deposition of sediments during a storm they are not applicable for assessing annual soil loss rates. Moreover storm event data may not be available everywhere prohibiting their extensive use.
NASA Technical Reports Server (NTRS)
1979-01-01
The solar system, installed in a new building, was designed to provide 52 percent of the estimated annual space heating load and 84 percent of the estimated annual potable hot water requirement. The liquid flat plate collectors are ground-mounted and cover a total area of 5125 square feet. The system will provide supplemental heat for the school's closed-loop water-to-air heat pump system and domestic hot water. The storage medium is water inside steel tanks with a capacity of 11,828 gallons for space heating and 1,600 gallons for domestic hot water. The solar heating facility is described and drawings are presented of the completed system which was declared operational in September 1978, and has functioned successfully since.
Code of Federal Regulations, 2011 CFR
2011-01-01
... OTHER PRODUCTS REQUIRED UNDER THE ENERGY POLICY AND CONSERVATION ACT (âAPPLIANCE LABELING RULEâ) Testing... water use rates of covered products are those found in the following standards: (1) Showerheads and... consumption, estimated annual operating cost, and energy efficiency rating, and of water use rate. 305.5...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anghileri, Daniela; Voisin, Nathalie; Castelletti, Andrea F.
In this study, we develop a forecast-based adaptive control framework for Oroville reservoir, California, to assess the value of seasonal and inter-annual forecasts for reservoir operation.We use an Ensemble Streamflow Prediction (ESP) approach to generate retrospective, one-year-long streamflow forecasts based on the Variable Infiltration Capacity hydrology model. The optimal sequence of daily release decisions from the reservoir is then determined by Model Predictive Control, a flexible and adaptive optimization scheme.We assess the forecast value by comparing system performance based on the ESP forecasts with that based on climatology and a perfect forecast. In addition, we evaluate system performance based onmore » a synthetic forecast, which is designed to isolate the contribution of seasonal and inter-annual forecast skill to the overall value of the ESP forecasts.Using the same ESP forecasts, we generalize our results by evaluating forecast value as a function of forecast skill, reservoir features, and demand. Our results show that perfect forecasts are valuable when the water demand is high and the reservoir is sufficiently large to allow for annual carry-over. Conversely, ESP forecast value is highest when the reservoir can shift water on a seasonal basis.On average, for the system evaluated here, the overall ESP value is 35% less than the perfect forecast value. The inter-annual component of the ESP forecast contributes 20-60% of the total forecast value. Improvements in the seasonal component of the ESP forecast would increase the overall ESP forecast value between 15 and 20%.« less
NASA Astrophysics Data System (ADS)
Musa, Tajul Ariffin; Leong, Shien Kwun; Abdullah, Khairul Anuar; Othman, Rusli
2012-11-01
This work proposes ISKANDARnet Ionospheric Outburst MOnitoring and alert System (IOMOS), along with Ionospheric Outburst Index (IOX) to develop an operational near real-time space weather service for Malaysia. The IOMOS is based on Global Positioning System (GPS) Network-based Real-Time Kinematic (NRTK) concept which is by nature for atmospheric (ionosphere and troposphere) modeling within the network coverage. The elegance of this solution lies in the fact that IOMOS utilize differential ionospheric residual from network of GPS baselines which incur no additional cost for operation. Users will be informed about the ionospheric perturbation through Short Message Service (SMS), email or Twitter®. This approach will ultimately beneficial for the navigation and satellite positioning communities, particularly during the coming Solar Cycle 24. In addition, a combination of local and global GPS network has been employed to study the equatorial ionosphere geomorphology and climatology in the Malaysian sector. Equatorial Total Electron Content (TEC) over Malaysia shows semi-annual, annual, and seasonal variations with maximum values appearing during equinoctial months and minimum during solstices months. The TEC value during vernal equinox is about 21% higher than autumnal equinox, and December solstice exceeds that at the June solstice by around 14%. It is also found that semi-annual variation is present at all levels of solar activity, whereas June solstice predominates December solstice during high solar activity for annual and seasonal variations. In near future, a near real-time TEC derivation system will be developed to support equatorial ionosphere modeling to enhance space weather service for Malaysia.
NASA Astrophysics Data System (ADS)
Kato, Takeyoshi; Sone, Akihito; Shimakage, Toyonari; Suzuoki, Yasuo
A microgrid (MG) is one of the measures for enhancing the high penetration of renewable energy (RE)-based distributed generators (DGs). For constructing a MG economically, the capacity optimization of controllable DGs against RE-based DGs is essential. By using a numerical simulation model developed based on the demonstrative studies on a MG using PAFC and NaS battery as controllable DGs and photovoltaic power generation system (PVS) as a RE-based DG, this study discusses the influence of forecast accuracy of PVS output on the capacity optimization and daily operation evaluated with the cost. The main results are as follows. The required capacity of NaS battery must be increased by 10-40% against the ideal situation without the forecast error of PVS power output. The influence of forecast error on the received grid electricity would not be so significant on annual basis because the positive and negative forecast error varies with days. The annual total cost of facility and operation increases by 2-7% due to the forecast error applied in this study. The impact of forecast error on the facility optimization and operation optimization is almost the same each other at a few percentages, implying that the forecast accuracy should be improved in terms of both the number of times with large forecast error and the average error.
Farrelly, Paul J; Losty, Paul D
2015-09-01
Delivery of health care in the UK faces enormous challenges with the Department of Health driving significant financial cost savings to ensure viability of public health services. We have analysed and modelled the concept of 'essential' and 'non-essential' paediatric surgery linked to the delivery of children's surgery in the NHS in England. Operation codes for surgical operations in newborns, children and adolescents were identified and Healthcare Resource Group tariffs-£Stg matched. Operations were designated as 'essential' or 'non-essential' based on the criteria-(1) life saving-neonatal surgery, emergency general surgery of childhood, cancer surgery; (2) debility if uncorrected; (3) aesthetics and (4) culture/attitude. Hospital Episode Statistics (HES) data were accessed and sampled for the total number of paediatric surgical operations-(age range 0-14 years) performed in NHS hospitals from 2009 to 2010. Annual costs (£) of both 'essential' and 'non-essential' operations were then calculated. The commonest 'essential' operations performed in children and adolescents in the year 2009-2010 was appendicectomy at a cost of over £51 million pounds. Costs of performing a selection of 'non-essential' paediatric surgery operations were >£14 million pounds/year. The NHs funds for example almost 11,000 paediatric circumcisions annually at a cost of >£8 million pounds-50% are performed for non-therapeutic reasons. Surgeons must engage and work actively with health care systems to ensure diminishing financial resources prioritise 'essential' operations for children. Commissioners must embrace evidence-based surgery. 'Essential' and 'non-essential' surgery has wide implications for the sustainability of the NHS and concepts herein developed can be applied to nations worldwide.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-14
... retain a benefit. Frequency of Collection: Ongoing. Estimated Annual Number of Respondents: 750. Estimated Total Annual Responses: 750. Estimated Time Per Response: 1 hour Estimated Total Annual Burden..., purchased, sold, or otherwise transferred; and (2) the dates of these transactions. Accredited wildlife...
Niklas, Karl J
2006-02-01
Life forms as diverse as unicellular algae, zooplankton, vascular plants, and mammals appear to obey quarter-power scaling rules. Among the most famous of these rules is Kleiber's (i.e. basal metabolic rates scale as the three-quarters power of body mass), which has a botanical analogue (i.e. annual plant growth rates scale as the three-quarters power of total body mass). Numerous theories have tried to explain why these rules exist, but each has been heavily criticized either on conceptual or empirical grounds. N,P-STOICHIOMETRY: Recent models predicting growth rates on the basis of how total cell, tissue, or organism nitrogen and phosphorus are allocated, respectively, to protein and rRNA contents may provide the answer, particularly in light of the observation that annual plant growth rates scale linearly with respect to standing leaf mass and that total leaf mass scales isometrically with respect to nitrogen but as the three-quarters power of leaf phosphorus. For example, when these relationships are juxtaposed with other allometric trends, a simple N,P-stoichiometric model successfully predicts the relative growth rates of 131 diverse C3 and C4 species. The melding of allometric and N,P-stoichiometric theoretical insights provides a robust modelling approach that conceptually links the subcellular 'machinery' of protein/ribosomal metabolism to observed growth rates of uni- and multicellular organisms. Because the operation of this 'machinery' is basic to the biology of all life forms, its allometry may provide a mechanistic explanation for the apparent ubiquity of quarter-power scaling rules.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-05
... Costs Number of Avg. burden per Total annual Type of respondent Form name/Form No. Number of responses per Total number of response (in burden (in Avg. hourly Total annual respondents respondent responses...
Thelin, Gail P.; Stone, Wesley W.
2013-01-01
A method was developed to calculate annual county level pesticide use for selected herbicides, insecticides, and fungicides applied to agricultural crops grown in the conterminous United States from 1992 through 2009. Pesticide-use data compiled by proprietary surveys of farm operations located within Crop Reporting Districts were used in conjunction with annual harvested-crop acreage reported by the U.S. Department of Agriculture National Agricultural Statistics Service (NASS) to calculate use rates per harvested crop acre, or an 'estimated pesticide use' (EPest) rate, for each crop by year. Pesticide-use data were not available for all Crop Reporting Districts and years. When data were unavailable for a Crop Reporting District in a particular year, EPest extrapolated rates were calculated from adjoining or nearby Crop Reporting Districts to ensure that pesticide use was estimated for all counties that reported harvested-crop acreage. EPest rates were applied to county harvested-crop acreage differently to obtain EPest-low and EPest-high estimates of pesticide-use for counties and states, with the exception of use estimates for California, which were taken from annual Department of Pesticide Regulation Pesticide Use Reports. Annual EPest-low and EPest-high use totals were compared with other published pesticide-use reports for selected pesticides, crops, and years. EPest-low and EPest-high national totals for five of seven herbicides were in close agreement with U.S. Environmental Protection Agency and National Pesticide Use Data estimates, but greater than most NASS national totals. A second set of analyses compared EPest and NASS annual state totals and state-by-crop totals for selected crops. Overall, EPest and NASS use totals were not significantly different for the majority of crop-stateyear combinations evaluated. Furthermore, comparisons of EPest and NASS use estimates for most pesticides had rank correlation coefficients greater than 0.75 and median relative errors of less than 15 percent. Of the 48 pesticide-by-crop combinations with 10 or more state-year combinations, 12 of the EPest-low and 17 of the EPest-high totals showed significant differences (p < 0.05) from NASS use estimates. The differences between EPest and NASS estimates did not follow consistent patterns related to particular crops, years, or states, and most correlation coefficients were greater than 0.75. EPest values from this study are suitable for making national, regional, and watershed assessments of annual pesticide use from 1992 to 2009. Although estimates are provided by county to facilitate estimation of watershed pesticide use for a wide variety of watersheds, there is a greater degree of uncertainty in individual county-level estimates when compared to Crop Reporting District or state-level estimates because (1) EPest crop-use rates were developed on the basis of pesticide use on harvested acres in multi-county areas (Crop Reporting Districts) and then allocated to county harvested cropland; (2) pesticide-by-crop use rates were not available for all Crop Reporting Districts in the conterminous United States, and extrapolation methods were used to estimate pesticide use for some counties; and (3) it is possible that surveyed pesticide-by-crop use rates do not reflect all agricultural use on all crops grown. The methods developed in this study also are applicable to other agricultural pesticides and years.
Estimates of ground-water pumpage from the Yakima River Basin aquifer system, Washington, 1960-2000
Vaccaro, J.J.; Sumioka, S.S.
2006-01-01
Ground-water pumpage in the Yakima River Basin, Washington, was estimated for eight categories of use for 1960-2000 as part of an investigation to assess groundwater availability in the basin. Methods used, pumpage estimates, reliability of the estimates, and a comparison with appropriated quantities are described. The eight categories of pumpage were public water supply, self-supplied domestic (exempt wells), irrigation, frost protection, livestock and dairy operations, industrial and commercial, fish and wildlife propagation, and ground-water claims. Pumpage estimates were based on methods that varied by the category and primarily represent pumpage for groundwater rights. Washington State Department of Ecology’s digital database has 2,874 active ground-water rights in the basin that can withdraw an annual quantity of about 529,231 acre-feet during dry years. Irrigation rights are for irrigation of about 129,570 acres. All but 220 of the rights were associated with well drillers’ logs, allowing for a spatial representation of the pumpage. Five-hundred and sixty of the irrigation rights were estimated to be standby/reserve rights. During this study, another 30 rights were identified that were not in the digital database. These rights can withdraw an annual quantity of about 20,969 acre-feet; about 6,700 acre-feet of these rights are near but outside the basin. In 1960, total annual pumpage in the basin, excluding standby/reserve pumpage, was about 115,776 acre-feet. By 2000, total annual pumpage was estimated to be 395,096 acre-feet, and excluding the standby/reserve rights, the total was 312,284 acre-feet. Irrigation accounts for about 60 percent of the pumpage, followed by public water supply at about 12 percent. The smallest category of pumpage was for livestock use with pumpage estimated to be 6,726 acre-feet. Total annual pumpage in 2000 was about 430 cubic feet per second, which is about 11 percent of the surface-water demand. Maximum pumpage is in July and August and during 2000, was about 100 cubic feet per second each month averaged over the Yakima River Basin aquifer system. During 2000, non-standby/reserve pumpage associated with ground-water rights was estimated to total 253,454 acre-feet, or about 198,290 acre-feet less than the appropriated quantity. The unused part of the appropriated value is about equivalent to the irrigation pumpage for primary rights.
Defense Environmental Restoration Program Annual Report to Congress for Fiscal Year 1989
1990-02-01
Sioux Falls 8 Air Force Ellsworth AFB 17 4 11 1 2 Joe Foss 6 2 2 South Dakota Totals 39 0 4 11 3 0 0) 4 Army AEDC Tullahoma 1 AFRC Johnson City 6...industrial applications. an Sl ** *. aion The Army has made several important advances in combat- Mobile Dioxin ing ground water and soil con...when operational. will treat ground water from all area drinking u ecovery water production wells and will meet all current health-baseda AFB
1985-07-01
and Operation 132 6.7.5 Safety 135 6.7.6 System Control Description 136 6.7.6.1 Coal Gasification 136 6.7.6.2 Gas Cooling, Cleaning and Compression...the hydrogen content. The gas is then desulfurized and heated before final polishing and feeding to the fuel cell. Receiving compressed fuel gas and...4 CO Shift 1 Stretford Desulfurizer 3 Gas Compressors 3 Material Handling(3) 3 Subtotal 39 Scheduled Shutdown 14 Total Annual Shutdown 53
Code of Federal Regulations, 2010 CFR
2010-04-01
... costs needed for the reliable operation of the irrigation facility infrastructure; (8) Maintenance of a... 25 Indians 1 2010-04-01 2010-04-01 false How does BIA determine the annual operation and... Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER IRRIGATION OPERATION AND...
Optimal adaptation to extreme rainfalls in current and future climate
NASA Astrophysics Data System (ADS)
Rosbjerg, Dan
2017-01-01
More intense and frequent rainfalls have increased the number of urban flooding events in recent years, prompting adaptation efforts. Economic optimization is considered an efficient tool to decide on the design level for adaptation. The costs associated with a flooding to the T-year level and the annual capital and operational costs of adapting to this level are described with log-linear relations. The total flooding costs are developed as the expected annual damage of flooding above the T-year level plus the annual capital and operational costs for ensuring no flooding below the T-year level. The value of the return period T that corresponds to the minimum of the sum of these costs will then be the optimal adaptation level. The change in climate, however, is expected to continue in the next century, which calls for expansion of the above model. The change can be expressed in terms of a climate factor (the ratio between the future and the current design level) which is assumed to increase in time. This implies increasing costs of flooding in the future for many places in the world. The optimal adaptation level is found for immediate as well as for delayed adaptation. In these cases, the optimum is determined by considering the net present value of the incurred costs during a sufficiently long time-span. Immediate as well as delayed adaptation is considered.
Optimal adaptation to extreme rainfalls under climate change
NASA Astrophysics Data System (ADS)
Rosbjerg, Dan
2017-04-01
More intense and frequent rainfalls have increased the number of urban flooding events in recent years, prompting adaptation efforts. Economic optimization is considered an efficient tool to decide on the design level for adaptation. The costs associated with a flooding to the T-year level and the annual capital and operational costs of adapting to this level are described with log-linear relations. The total flooding costs are developed as the expected annual damage of flooding above the T-year level plus the annual capital and operational costs for ensuring no flooding below the T-year level. The value of the return period T that corresponds to the minimum of the sum of these costs will then be the optimal adaptation level. The change in climate, however, is expected to continue in the next century, which calls for expansion of the above model. The change can be expressed in terms of a climate factor (the ratio between the future and the current design level) which is assumed to increase in time. This implies increasing costs of flooding in the future for many places in the world. The optimal adaptation level is found for immediate as well as for delayed adaptation. In these cases the optimum is determined by considering the net present value of the incurred costs during a sufficiently long time span. Immediate as well as delayed adaptation is considered.
Groundwater recharge in Wisconsin--Annual estimates for 1970-99 using streamflow data
Gebert, Warren A.; Walker, John F.; Hunt, Randall J.
2011-01-01
The groundwater component of streamflow is important because it is indicative of the sustained flow of a stream during dry periods, is often of better quality, and has a smaller range of temperatures, than surface contributions to streamflow. All three of these characteristics are important to the health of aquatic life in a stream. If recharge to the aquifers is to be preserved or enhanced, it is important to understand the present partitioning of total streamflow into base flow and stormflow. Additionally, an estimate of groundwater recharge is important for understanding the flows within a groundwater system-information important for water availability/sustainability or other assessments. The U.S. Geological Survey operates numerous continuous-record streamflow-gaging stations (Hirsch and Norris, 2001), which can be used to provide estimates of average annual base flow. In addition to these continuous record sites, Gebert and others (2007) showed that having a few streamflow measurements in a basin can appreciably reduce the error in a base-flow estimate for that basin. Therefore, in addition to the continuous-record gaging stations, a substantial number of low-flow partial-record sites (6 to 15 discharge measurements) and miscellaneous-measurement sites (1 to 3 discharge measurements) that were operated during 1964-90 throughout the State were included in this work to provide additional insight into spatial distribution of annual base flow and, in turn, groundwater recharge.
Summary of Key Operating Statistics: Data Collected from the 2009 Annual Institutional Report
ERIC Educational Resources Information Center
Accrediting Council for Independent Colleges and Schools, 2010
2010-01-01
The Accrediting Council for Independent Colleges and Schools (ACICS) provides the Summary of Key Operating Statistics (KOS) as an annual review of the performance and key measurements of the more than 800 private post-secondary institutions we accredit. This edition of the KOS contains information based on the 2009 Annual Institutional Reports…
Serial MRI and CSF biomarkers in normal aging, MCI, and AD
Vemuri, P.; Wiste, H.J.; Weigand, S.D.; Knopman, D.S.; Trojanowski, J.Q.; Shaw, L.M.; Bernstein, M.A.; Aisen, P.S.; Weiner, M.; Petersen, R.C; Jack, C.R
2010-01-01
Objective: To compare the annual change in MRI and CSF biomarkers in cognitively normal (CN), amnestic mild cognitive impairment (aMCI), and Alzheimer disease (AD). Comparisons were based on intergroup discrimination, correlation with concurrent cognitive/functional changes, relationships to APOE genotype, and sample sizes for clinical trials. Methods: We used data from the Alzheimer's Disease Neuroimaging Initiative study consisting of CN, aMCI, and AD cohorts with both baseline and 12-month follow-up CSF and MRI. The annual change in CSF (total-tau [t-tau], Aβ1-42) and MRI (change in ventricular volume) was obtained in 312 subjects (92 CN, 149 aMCI, 71 AD). Results: There was no significant average annual change in either CSF biomarker in any clinical group except t-tau in CN; moreover, the annual change did not differ by clinical group in pairwise comparisons. In contrast, annual increase in ventricular volume increased in the following order, AD > aMCI > CN, and differences were significant between all clinical groups in pairwise comparisons. Ventricular volume increase correlated with concurrent worsening on cognitive/functional indices in aMCI and AD whereas evidence of a similar correlation with change in CSF measures was unclear. The annual changes in MRI differed by APOE ε4 status overall and among aMCI while annual changes in CSF biomarkers did not. Estimated sample sizes for clinical trials are notably less for MRI than the CSF or clinical measures. Conclusions: Unlike the CSF biomarkers evaluated, changes in serial structural MRI are correlated with concurrent change on general cognitive and functional indices in impaired subjects, track with clinical disease stage, and are influenced by APOE genotype. GLOSSARY AD = Alzheimer disease; ADAS-Cog = Alzheimer's Disease Assessment Scale–cognitive subscale; ADNI = Alzheimer's Disease Neuroimaging Initiative; aMCI = amnestic mild cognitive impairment; AUROC = area under the receiver operator characteristic curve; BSI = boundary shift integral; CDR-SB = Clinical Dementia Rating–sum of boxes; CN = cognitively normal; MMSE = Mini-Mental State Examination; NFT = neurofibrillary tangle; NT = neuropil thread; PiB = Pittsburgh compound B; t-tau = total-tau. PMID:20625167
GENERAL EXTERIOR VIEW, LOOKING NORTHEAST, OF THE SURFACE PLANT WITH ...
GENERAL EXTERIOR VIEW, LOOKING NORTHEAST, OF THE SURFACE PLANT WITH CONVEYORS. JIM WALTER RESOURCES INC. MINING DIVISION OPERATES FOUR UNDERGROUND COAL MINES IN THE BLUE CREEK COAL FIELD OF BIRMINGHAM DISTRICT, THREE IN TUSCALOOSA COUNTY AND ONE IN JEFFERSON COUNTY. TOTAL ANNUAL PRODUCTION IS 8,000,000 TONS. AT 2,300 DEEP, JIM WALTER'S BROOKWOOD MINES ARE THE DEEPEST UNDERGROUND COAL MINES IN NORTH AMERICA. THEY PRODUCE A HIGH-GRADE MEDIUM VOLATILE LOW SULPHUR METALLURGICAL COAL. THE BROOKWOOD NO. 5 MINE (PICTURED IN THIS PHOTOGRAPH) EMPLOYS THE LONGWALL MINING TECHNIQUES WITH BELTS CONVEYING COAL FROM UNDERGROUND OPERATIONS TO THE SURFACE. - JIm Walter Resources, Incorporated, Brookwood No. 5 Mine, 12972 Lock 17 Road, Brookwood, Tuscaloosa County, AL
NASA Technical Reports Server (NTRS)
Frost, W. (Editor); Camp, D. W. (Editor); Durham, D. E. (Editor)
1978-01-01
The proceedings of a workshop held at the University of Tennessee Space Institute, Tullahoma, Tennessee, March 28-30, 1978, are reported. The workshop was jointly sponsored by NASA, NOAA, FAA, and brought together many disciplines of the aviation communities in round table discussions. The major objectives of the workshop are to satisfy such needs of the sponsoring agencies as the expansion of our understanding and knowledge of the interactions of the atmosphere with aviation systems, as the better definition and implementation of services to operators, and as the collection and interpretation of data for establishing operational criteria, relating the total meteorological inputs from the atmospheric sciences to the needs of aviation communities.
High-Performance Integrated Control of water quality and quantity in urban water reservoirs
NASA Astrophysics Data System (ADS)
Galelli, S.; Castelletti, A.; Goedbloed, A.
2015-11-01
This paper contributes a novel High-Performance Integrated Control framework to support the real-time operation of urban water supply storages affected by water quality problems. We use a 3-D, high-fidelity simulation model to predict the main water quality dynamics and inform a real-time controller based on Model Predictive Control. The integration of the simulation model into the control scheme is performed by a model reduction process that identifies a low-order, dynamic emulator running 4 orders of magnitude faster. The model reduction, which relies on a semiautomatic procedural approach integrating time series clustering and variable selection algorithms, generates a compact and physically meaningful emulator that can be coupled with the controller. The framework is used to design the hourly operation of Marina Reservoir, a 3.2 Mm3 storm-water-fed reservoir located in the center of Singapore, operated for drinking water supply and flood control. Because of its recent formation from a former estuary, the reservoir suffers from high salinity levels, whose behavior is modeled with Delft3D-FLOW. Results show that our control framework reduces the minimum salinity levels by nearly 40% and cuts the average annual deficit of drinking water supply by about 2 times the active storage of the reservoir (about 4% of the total annual demand).
Unit Cost Analysis of PET-CT at an Apex Public Sector Health Care Institute in India.
Gajuryal, S H; Daga, A; Siddharth, V; Bal, C S; Satpathy, S
2017-01-01
PET/CT scan service is one of the capital intensive and revenue-generating centres of a tertiary care hospital. The cost associated with the provisioning of PET services is dependent upon the unit costs of the resources consumed. The study aims to determine the cost of providing PET/CT Scan services in a hospital. This descriptive and observational study was conducted in the Department of Nuclear Medicine at a tertiary apex teaching hospital in New Delhi, India in the year 2014-15. Traditional costing methodology was used for calculating the unit cost of PET/CT scan service. The cost was calculated under two heads that is capital and operating cost. Annualized cost of capital assets was calculated using methodology prescribed by WHO and operating costs was taken on an actual basis. Average number of PET/CT scan performed in a day is 30. The annual cost of providing PET/CT scan services was calculated to be 65,311,719 Indian Rupees (INR) (US$ 1,020,496), while the unit cost of PET scan was calculated to be 9625.92 INR (US$ 150). 3/4th cost was spent on machinery and equipment (75.3%) followed by healthcare personnel (11.37%), electricity (5%), consumables and supplies (4%) engineering maintenance (3.24%), building, furniture and HVAC capital cost (0.76%), and manifold cost (0.05%). Of the total cost, 76% was capital cost while the remaining was operating cost. Total cost for establishing PET/CT scan facility with cyclotron and chemistry module and PET/CT scan without cyclotron and chemistry module was calculated to be INR 610,873,517 (US$9944899) and 226,745,158 (US$3542893), respectively. (US$ 1=INR 64).
Summary Report of Journal Operations, 2016.
2017-01-01
Presents a summary report of journal operations compiled from the 2016 annual reports of the Council of Editors and from Central Office records. Also includes a summary report of division journal operations compiled from the 2016 annual reports of the division journal editors. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
47 CFR 25.170 - Annual reporting requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... SATELLITE COMMUNICATIONS Applications and Licenses Reporting Requirements for Space Station Operators § 25.170 Annual reporting requirements. All operators of U.S.-licensed space stations and operators of non-U.S.-licensed space stations granted U.S. market access must, on June 30 of each year, file a report...
Christensen, Victoria G.; Kieta, Kristen A.
2014-01-01
This study examined conservation easements and their effectiveness at reducing phosphorus and solids transport to streams. The U.S. Geological Survey cooperated with the Minnesota Board of Water and Soil Resources and worked collaboratively with the Hawk Creek Watershed Project to examine the West Fork Beaver Creek Basin in Renville County, which has the largest number of Reinvest In Minnesota land retirement contracts in the State (as of 2013). Among all conservation easement programs, a total of 24,218 acres of agricultural land were retired throughout Renville County, and 2,718 acres were retired in the West Fork Beaver Creek Basin from 1987 through 2012. Total land retirement increased steadily from 1987 until 2000. In 2000, land retirement increased sharply because of the Minnesota River Conservation Reserve Enhancement Program, then leveled off when the program ended in 2002. Streamflow data were collected during 1999 through 2011, and total phosphorus and total suspended solids data were collected during 1999 through 2012. During this period, the highest peak streamflow of 1,320 cubic feet per second was in March 2010. Total phosphorus and total suspended solids are constituents that tend to increase with increases in streamflow. Annual flow-weighted mean total-phosphorus concentrations ranged from 0.140 to 0.759 milligrams per liter, and annual flow-weighted mean total suspended solids concentrations ranged from 21.3 to 217 milligrams per liter. Annual flow-weighted mean total phosphorus and total suspended solids concentrations decreased steadily during the first 4 years of water-quality sample collection. A downward trend in flow-weighted mean total-phosphorus concentrations was significant from 1999 through 2008; however, flow-weighted total-phosphorus concentrations increased substantially in 2009, and the total phosphorus trend was no longer significant. The high annual flow-weighted mean concentrations for total phosphorus and total suspended solids in 2009 were affected by outlier concentrations documented in March 2009. Agricultural land-retirement data only were available through 2008; therefore, it was not possible to compare total phosphorus and total suspended solids concentrations to agricultural land-retirement data for 2009–11. A downward trend in annual flow-weighted mean total-phosphorus concentrations was related significantly to annual land retirement for 1999–2008. The relation between annual flow-weighted mean total suspended solids concentration and annual land retirement was not statistically significant for 1999–2008. If land-retirement data had been available for 2009–11, it is possible that the relation between total phosphorus and land retirement would no longer be evident because of the marked increase in flow-weighted concentrations during 2009. Alternatively, the increase in annual flow-weighted mean total-phosphorus concentrations during 2009–11 may be because of other factors, including industrial discharges, increases in drain tile installation, changes in land use including decreases in agricultural land retirement after 2008, increases in erosion, increases in phosphorus applications to fields, or unknown causes. Inclusion of land-retirement effects in agency planning along with other factors adds perspective with regard to the broader picture of interdependent systems and allows agencies to make informed decisions on the benefits of perpetual easements compared to limited duration easements.
Orr, R Douglas; Sodhi, Nipun; Dalton, Sarah E; Khlopas, Anton; Sultan, Assem A; Chughtai, Morad; Newman, Jared M; Savage, Jason; Mroz, Thomas E; Mont, Michael A
2018-02-02
Relative value units (RVUs) are a compensation model based on the effort required to provide a procedure or service to a patient. Thus, procedures that are more complex and require greater technical skill and aftercare, such as multilevel spine surgery, should provide greater physician compensation. However, there are limited data comparing RVUs with operative time. Therefore, this study aims to compare mean (1) operative times; (2) RVUs; and (3) RVU/min between posterior segmental instrumentation of 3-6, 7-12, and ≥13 vertebral segments, and to perform annual cost difference analysis. A total of 437 patients who underwent instrumentation of 3-6 segments (Cohort 1, current procedural terminology [CPT] code: 22842), 67 patients who had instrumentation of 7-12 segments (Cohort 2, CPT code: 22843), and 16 patients who had instrumentation of ≥13 segments (Cohort 3, CPT code: 22844) were identified from the National Surgical Quality Improvement Program (NSQIP) database. Mean operative times, RVUs, and RVU/min, as well as an annualized cost difference analysis, were calculated and compared using Student t test. This study received no funding from any party or entity. Cohort 1 had shorter mean operative times than Cohorts 2 and 3 (217 minutes vs. 325 minutes vs. 426 minutes, p<.05). Cohort 1 had a lower mean RVU than Cohorts 2 and 3 (12.6 vs. 13.4 vs. 16.4). Cohort 1 had a greater RVU/min than Cohorts 2 and 3 (0.08 vs. 0.05, p<.05; vs. 0.08 vs. 0.05, p>.05). A $112,432.12 annualized cost difference between Cohorts 1 and 2, a $176,744.76 difference between Cohorts 1 and 3, and a $64,312.55 difference between Cohorts 2 and 3 were calculated. The RVU/min takes into account not just the value provided but also the operative times required for highly complex cases. The RVU/min for fewer vertebral level instrumentation being greater (0.08 vs. 0.05), as well as the $177,000 annualized cost difference, indicates that compensation is not proportional to the added time, effort, and skill for more complex cases. Copyright © 2018 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
G. B. Mitchem
2001-08-22
This annual progress and performance evaluation report discusses the groundwater remedial actions in the 100 Area, including the interim actions at the 100-HR-3 and 100-KR-4 Operable Units, and also discusses the expedited response action in the 100-NR-2 operable unit.
Does electronic health record use improve hospital financial performance? Evidence from panel data.
Collum, Taleah H; Menachemi, Nir; Sen, Bisakha
2016-01-01
The aim of this study was to examine the impact of electronic health record (EHR) adoption on hospital financial performance. We constructed a longitudinal panel using data from the three secondary sources: (a) the 2007-2010 American Hospital Association (AHA) Annual Survey, (b) the 2007-2010 AHA Annual Survey Information Technology Supplement, and (c) the 2007-2011 Medicare Cost Reports from Centers for Medicare and Medicaid Services. Because potential financial benefits attributable to EHR adoption may take some time to accrue, we ran regressions with lags of 1 and 2 years that included hospital and year fixed effects to examine the relationship between the level of EHR adoption and three hospital financial performance measures. A change in the level of EHR adoption was not associated with changes in operating margin or return on assets within hospitals. However, total margin was significantly improved, after 2 years, in hospitals that moved from no EHR to having a comprehensive EHR in all areas of their hospital (β = 0.030, p < .034). On the other hand, hospitals that increased their level of EHR adoption but did not achieve hospital-wide comprehensive adoption did not experience changes in any financial performance measures examined. The improvements in total margin, as opposed to operating margin, are likely due to hospital incentive payments under the Health Information Technology for Economic and Clinical Health Act that are reflected in nonpatient revenues and therefore show up in total margin calculations. Thus, after 2 years of EHR adoption, hospital financial performance is observed to improve based only on meaningful use incentive payments. More research will be needed to determine whether EHR adoption impacts financial performance on a longer time horizon.
Examining variation in treatment costs: a cost function for outpatient methadone treatment programs.
Dunlap, Laura J; Zarkin, Gary A; Cowell, Alexander J
2008-06-01
To estimate a hybrid cost function of the relationship between total annual cost for outpatient methadone treatment and output (annual patient days and selected services), input prices (wages and building space costs), and selected program and patient case-mix characteristics. Data are from a multistate study of 159 methadone treatment programs that participated in the Center for Substance Abuse Treatment's Evaluation of the Methadone/LAAM Treatment Program Accreditation Project between 1998 and 2000. Using least squares regression for weighted data, we estimate the relationship between total annual costs and selected output measures, wages, building space costs, and selected program and patient case-mix characteristics. Findings indicate that total annual cost is positively associated with program's annual patient days, with a 10 percent increase in patient days associated with an 8.2 percent increase in total cost. Total annual cost also increases with counselor wages (p<.01), but no significant association is found for nurse wages or monthly building costs. Surprisingly, program characteristics and patient case mix variables do not appear to explain variations in methadone treatment costs. Similar results are found for a model with services as outputs. This study provides important new insights into the determinants of methadone treatment costs. Our findings concur with economic theory in that total annual cost is positively related to counselor wages. However, among our factor inputs, counselor wages are the only significant driver of these costs. Furthermore, our findings suggest that methadone programs may realize economies of scale; however, other important factors, such as patient access, should be considered.
Shaikh, Maaz; Woodward, Mark; Rahimi, Kazem; Patel, Anushka; Rath, Santosh; MacMahon, Stephen; Jha, Vivekanand
2015-05-01
Information on the use of major surgery in India is scarce. In this study we aimed to bridge this gap by auditing hospital claims from Rajiv Aarogyasri Community Health Insurance Scheme, which provides access to free hospital care through state-funded insurance to 68 million beneficiaries, an estimated 81% of population in the states of Telangana and Andhra Pradesh. Publicly available deidentified hospital claim data for all surgery procedures conducted between mid-2008 and mid-2012 were compiled across all 23 districts in Telangana and Andhra Pradesh. A total of 677,332 operative admissions (80% at private hospitals) were recorded at an annual rate of 259 per 100,000 beneficiaries, with male subjects accounting for 56% of admissions. Injury was the most common cause for operative admission (27%) with operative correction of long bone fractures being the most common procedure (20%) identified in the audit. Diseases of the digestive (16%), genitourinary (12%), and musculoskeletal (10%) systems were other leading causes for operative admissions. Most hospital bed-days were used by admissions for injuries (31%) and diseases of the digestive (17%) and musculoskeletal system (11%) costing 19%, 13%, and 11% of reimbursement. Operations on the circulatory system (8%) accounted for 21% of reimbursements. Annual per capita cost of operative claims was US$1.48. The use of surgery by an insured population in India continued to be low despite access to financing comparable with greater spending countries, highlighting need for strategies, beyond traditional health financing, that prioritize improvement in access, delivery, and use of operative care. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Zema, Demetrio Antonio; Nicotra, Angelo; Tamburino, Vincenzo; Marcello Zimbone, Santo
2017-04-01
The availability of geodetic heads and considerable water flows in collective irrigation networks suggests the possibility of recovery potential energy using small hydro power plants (SHPP) at sustainable costs. This is the case of many Water Users Associations (WUA) in Calabria (Southern Italy), where it could theoretically be possible to recovery electrical energy out of the irrigation season. However, very few Calabrian WUAs have currently built SHPP in their irrigation networks and thus in this region the potential energy is practically fully lost. A previous study (Zema et al., 2016) proposed an original and simple model to site turbines and size their power output as well as to evaluate profits of SHPP in collective irrigation networks. Applying this model at regional scale, this paper estimates the theoretical energy production and the economic performances of SHPP installed in collective irrigation networks of Calabrian WUAs. In more detail, based on digital terrain models processed by GIS and few parameters of the water networks, for each SHPP the model provides: (i) the electrical power output; (iii) the optimal water discharge; (ii) costs, revenues and profits. Moreover, the map of the theoretical energy production by SHPP in collective irrigation networks of Calabria was drawn. The total network length of the 103 water networks surveyed is equal to 414 km and the total geodetic head is 3157 m, of which 63% is lost due to hydraulic losses. Thus, a total power output of 19.4 MW could theoretically be installed. This would provide an annual energy production of 103 GWh, considering SHPPs in operation only out of the irrigation season. The single irrigation networks have a power output in the range 0.7 kW - 6.4 MW. However, the lowest SHPPs (that is, turbines with power output under 5 kW) have been neglected, because the annual profit is very low (on average less than 6%, Zema et al., 2016). On average each irrigation network provides an annual revenue from electrical energy sale of about 103000 €. Even though this revenue may appear quite low, it represents an important share of the annual WUA income. For the entire region, the total revenues from recovery energy in collective irrigation networks through SHPPs have been estimated in about 12 million Euros; investment and operating costs have been evaluated by parametric equations and the total profit theoretically available for each WUA has been quantified. This study has shown the economic opportunity of integrating SHPP in existing collecting irrigation networks of WUAs, in view of providing additional economic resources for users and enhancing the exploitation of a renewable energy source. REFERENCE Zema D.A., Nicotra A., Tamburino V., Zimbone S.M. 2016. A simple method to evaluate the technical and economic feasibility of micro hydro power plants in existing irrigation systems. Renewable Energy 85, 498-506. DOI: 10.1016/j.renene.2015.06.066.
Specialization and the Current Practices of General Surgeons
Decker, Marquita R; Dodgion, Christopher M; Kwok, Alvin C; Hu, Yue-Yung; Havlena, Jeff A; Jiang, Wei; Lipsitz, Stuart R; Kent, K Craig; Greenberg, Caprice C
2014-01-01
Background The impact of specialization on the practice of general surgery has not been characterized. Our goal was to assess general surgeons’ operative practices to inform surgical education and workforce planning. Study Design We examined the practices of general surgeons identified in the 2008 State Inpatient and Ambulatory Surgery Databases of the Healthcare Cost and Utilization Project (HCUP) for three US states. Operations were identified using ICD-9 and CPT codes linked to encrypted physician identifiers. For each surgeon, total operative volume and the percentage of practice comprised of their most common operation were calculated. Correlation was measured between general surgeons’ case volume and the number of other specialists in a health service area. Results There were 1,075 general surgeons who performed 240,510 operations in 2008. The mean operative volume for each surgeon was 224 annual procedures. General surgeons performed an average of 23 different types of operations. For the majority of general surgeons, their most common procedure comprised no more than 30% of total practice. The most common operations, ranked by the frequency that they appeared as general surgeons’ top procedure, included: cholecystectomy, colonoscopy, endoscopy, and skin excision. The proportion of general surgery practice comprised of endoscopic procedures inversely correlated with the number of gastroenterologists in the health service area (Rho = - 0.50, p = 0.005). Conclusions Despite trends toward specialization, the current practices of general surgeons remain heterogeneous. This indicates a continued demand for broad-based surgical education to allow future surgeons to tailor their practices to their environment. PMID:24210145
78 FR 49321 - Proposed Agency Information Collection Activities; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-13
.... Residents. Respondent Universe: 1,000 individuals. Frequency of Submission: On occasion. Respondent Total annual Average time per Total annual Form number universe responses response burden hours Alleged...
77 FR 77181 - Proposed Agency Information Collection Activities; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-31
...: Railroad Employees. Respondent Universe: 11,000 Railroad Employees. Frequency of Submission: On occasion. Reporting Burden: Total Respondent Total annual Average Time annual CFR section universe responses per...
77 FR 8297 - Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-14
... account for an 1800-hour work year and multiplied by 2.93 to account for bonuses, firm size, employee... for each of approximately 2400 purchasers annually (at an estimated $67 per hour),\\1\\ for a total annual burden of 120 hours (at a total annual cost of $8,040). \\1\\ $67/hour figure for a Compliance Clerk...
Wang, Hongguang
2018-01-01
Annual power load forecasting is not only the premise of formulating reasonable macro power planning, but also an important guarantee for the safety and economic operation of power system. In view of the characteristics of annual power load forecasting, the grey model of GM (1,1) are widely applied. Introducing buffer operator into GM (1,1) to pre-process the historical annual power load data is an approach to improve the forecasting accuracy. To solve the problem of nonadjustable action intensity of traditional weakening buffer operator, variable-weight weakening buffer operator (VWWBO) and background value optimization (BVO) are used to dynamically pre-process the historical annual power load data and a VWWBO-BVO-based GM (1,1) is proposed. To find the optimal value of variable-weight buffer coefficient and background value weight generating coefficient of the proposed model, grey relational analysis (GRA) and improved gravitational search algorithm (IGSA) are integrated and a GRA-IGSA integration algorithm is constructed aiming to maximize the grey relativity between simulating value sequence and actual value sequence. By the adjustable action intensity of buffer operator, the proposed model optimized by GRA-IGSA integration algorithm can obtain a better forecasting accuracy which is demonstrated by the case studies and can provide an optimized solution for annual power load forecasting. PMID:29768450
Phosphorus and nitrogen in runoff after phosphorus- or nitrogen-based manure applications.
Miller, Jim J; Chanasyk, David S; Curtis, Tony W; Olson, Barry M
2011-01-01
Application of beef cattle () manure based on nitrogen (N) requirements of crops has resulted in elevated concentrations of soil test phosphorus (P) in surface soils, and runoff from this cropland can contribute to eutrophication of surface waters. We conducted a 3-yr field study (2005-2007) on a Lethbridge loam soil cropped to dryland barley () in southern Alberta, Canada to evaluate the effect of annual and triennial P-based and annual N-based feedlot manure on P and N in runoff. The manure was spring applied and incorporated. There was one unamended control plot. A portable rainfall simulator was used to generate runoff in the spring of each year after recent manure incorporation, and the runoff was analyzed for total P, total dissolved P, total particulate P, dissolved reactive P, total N, total dissolved N, total particulate N, NO-N, and NH-N. Annual or triennial P-based application resulted in significantly ( ≤ 0.05) lower (by 50 to 94%) concentrations or loads of mainly dissolved P fractions in runoff for some years compared with annual N-based application, and this was related to lower rates of annual manure P applied. For example, mean dissolved reactive P concentrations in 2006 and 2007 were significantly lower for the annual P-based (0.12-0.20 mg L) than for the annual N-based application (0.24-0.48 mg L), and mean values were significantly lower for the triennial P-based (0.06-0.13 mg L) than for the annual N-based application. In contrast, other P fractions in runoff were unaffected by annual P-based application. Our findings suggested no environmental benefit of annual P-based application over triennial P-based application with respect to P and N in runoff. Similar concentrations and loads of N fractions in runoff for the P- and N-based applications indicated that shifting to a P-based application would not significantly influence N in runoff. American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America.
Mullaney, John R.; Schwarz, Gregory E.
2013-01-01
The total nitrogen load to Long Island Sound from Connecticut and contributing areas to the north was estimated for October 1998 to September 2009. Discrete measurements of total nitrogen concentrations and continuous flow data from 37 water-quality monitoring stations in the Long Island Sound watershed were used to compute total annual nitrogen yields and loads. Total annual computed yields and basin characteristics were used to develop a generalized-least squares regression model for use in estimating the total nitrogen yields from unmonitored areas in coastal and central Connecticut. Significant variables in the regression included the percentage of developed land, percentage of row crops, point-source nitrogen yields from wastewater-treatment facilities, and annual mean streamflow. Computed annual median total nitrogen yields at individual monitoring stations ranged from less than 2,000 pounds per square mile in mostly forested basins (typically less than 10 percent developed land) to more than 13,000 pounds per square mile in urban basins (greater than 40 percent developed) with wastewater-treatment facilities and in one agricultural basin. Medians of computed total annual nitrogen yields for water years 1999–2009 at most stations were similar to those previously computed for water years 1988–98. However, computed medians of annual yields at several stations, including the Naugatuck River, Quinnipiac River, and Hockanum River, were lower than during 1988–98. Nitrogen yields estimated for 26 unmonitored areas downstream from monitoring stations ranged from less than 2,000 pounds per square mile to 34,000 pounds per square mile. Computed annual total nitrogen loads at the farthest downstream monitoring stations were combined with the corresponding estimates for the downstream unmonitored areas for a combined estimate of the total nitrogen load from the entire study area. Resulting combined total nitrogen loads ranged from 38 to 68 million pounds per year during water years 1999–2009. Total annual loads from the monitored basins represent 63 to 74 percent of the total load. Computed annual nitrogen loads from four stations near the Massachusetts border with Connecticut represent 52 to 54 percent of the total nitrogen load during water years 2008–9, the only years with data for all the border sites. During the latter part of the 1999–2009 study period, total nitrogen loads to Long Island Sound from the study area appeared to increase slightly. The apparent increase in loads may be due to higher than normal streamflows, which consequently increased nonpoint nitrogen loads during the study, offsetting major reductions of nitrogen from wastewater-treatment facilities. Nitrogen loads from wastewater treatment facilities declined as much as 2.3 million pounds per year in areas of Connecticut upstream from the monitoring stations and as much as 5.8 million pounds per year in unmonitored areas downstream in coastal and central Connecticut.
75 FR 50780 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-17
... the following public information collection request (ICR) to the Office of Management and Budget (OMB... things, a description of the likely respondents, proposed frequency of response, and estimated total... of Respondents: 53. Total Annual Number of Responses: 1,437,897. Total Annual Burden Hours: 23,964...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-05
... groundfish sector to request exemptions from Federal fishing regulations through its annual operations plan... rule implementing the annual sector operations plans. However, sectors can request exemptions at any...-funded at-sea monitoring program will be required to develop a monitoring plan as part of its operation...
38th Annual Maintenance & Operations Cost Study for Colleges
ERIC Educational Resources Information Center
Agron, Joe
2009-01-01
The nation's colleges are feeling the pinch of the economic downturn, and maintenance and operations (M&O) budgets especially are under pressure. This article presents data from the 38th annual Maintenance & Operations Cost Study for colleges that can help one in benchmarking expenditures at one's institution. Data provided only targets two-year…
38th Annual Maintenance & Operations Cost Study for Schools
ERIC Educational Resources Information Center
Agron, Joe
2009-01-01
Despite the worst economic environment in generations, spending by K-12 institutions on maintenance and operations (M&O) held its own--defying historical trends that have shown M&O spending among the most affected in times of budget tightening. This article presents data from the 38th annual Maintenance & Operations Cost Study for…
Wright, Scott A.; Grams, Paul E.
2010-01-01
This report describes numerical modeling simulations of sand transport and sand budgets for reaches of the Colorado River below Glen Canyon Dam. Two hypothetical Water Year 2011 annual release volumes were each evaluated with six hypothetical operational scenarios. The six operational scenarios include the current operation, scenarios with modifications to the monthly distribution of releases, and scenarios with modifications to daily flow fluctuations. Uncertainties in model predictions were evaluated by conducting simulations with error estimates for tributary inputs and mainstem transport rates. The modeling results illustrate the dependence of sand transport rates and sand budgets on the annual release volumes as well as the within year operating rules. The six operational scenarios were ranked with respect to the predicted annual sand budgets for Marble Canyon and eastern Grand Canyon reaches. While the actual WY 2011 annual release volume and levels of tributary inputs are unknown, the hypothetical conditions simulated and reported herein provide reasonable comparisons between the operational scenarios, in a relative sense, that may be used by decision makers within the Glen Canyon Dam Adaptive Management Program.
Smith, Tyler; Elson, Leah; Anderson, Christopher; Leone, William
2016-01-01
Despite technological advances in operative technique and component materials, the total knee arthroplasty (TKA) revision burden, in the United States, has remained static for the past decade. In light of an anticipated exponential increase in annual surgical volume, it is important to thoroughly understand contemporary challenges associated with technologically driven TKA. This descriptive literature review harvested 69 relevant publications to extrapolate patient trends, benefits, costs, and complications associated with computer-assisted surgery, patient specific instrumentation, and intra-operative sensors. Due to additional charges, a steep learning curve, and questionable cost-effectiveness, widespread use of these systems has been limited. Intra-operative sensors are a relatively recent development, and have been shown to improve both soft-tissue balance and overall functional outcomes at a relatively low price and without disrupting operative workflow. The introduction of new technology into the operating suite should be considered carefully, especially with respect to combined clinically efficacy and cost.
Phosphorus in waters from sewage sludge amended lysimeters.
Hinesly, T D; Jones, R L
1990-01-01
In surface waters, phosphorus (P) concentrations exceeding 0.05 mg liter(-1) may cause eutrophic conditions. This study was undertaken to measure total P concentrations in runoff and tile drainage waters from land receiving either inorganic fertilizer or anaerobically digested sewage sludge. Total P was measured in runoff and tile drainage waters during 2 years of sample collections from instrumented, large-scale lysimeters planted to corn (Zea mays L.). During the 3 years prior to monitoring P concentrations, six of the lysimeter plots had been amended with anaerobically digested sewage sludge which supplied 5033 kg P per ha. Additional sludge applications supplied 1058 and 1989 kg P per ha during the first and second years of monitoring operations, respectively. Another six lysimeters were annually treated with fertilizer which included P applications amounting to 112 kg ha(-1). For years 1 and 2, respectively, annual losses from lysimeters treated with sewage sludge were 4.27 and 0.35 kg P per ha in runoff and 0.91 from 0.91 and 0.51 kg Per P per ha in drainage waters. Parallel annual losses of P from lysimeters treated with superphosphate were 2.15 and 0.17 kg ha(-1) in runoff and 0.53 and 0.35 kg ha(-1) in tile drainage waters. Sludge applications did not significantly change absolute soil contents of organic P, but did decrease the per cent of total P present in organic forms. Sludge and soil, respectively, contained 21 and 36% of their total P contents in organic forms. In sludge and soil about 85 and 64% of their respective total inorganic P contents were associated with the Al and Fe fractions. Sludge applications significantly increased soil contents of P in the saloid (water-soluble plus P extracted with 1 N NH(4)Cl), Al, Fe and reductant soluble P fractions, but contents of Ca-bound P were not changed. Total P contents of the soil below a depth of 30 cm were not affected by sludge incorporated to a depth of about 15 cm by plowing.
Alejo-Alvarez, Luz; Guzmán-Fierro, Víctor; Fernández, Katherina; Roeckel, Marlene
2016-11-01
A full-scale process for the treatment of 80 tons per day of poultry manure was designed and optimized. A total ammonia nitrogen (TAN) balance was performed at steady state, considering the stoichiometry and the kinetic data from the anaerobic digestion and the anaerobic ammonia oxidation. The equipment, reactor design, investment costs, and operational costs were considered. The volume and cost objective functions optimized the process in terms of three variables: the water recycle ratio, the protein conversion during AD, and the TAN conversion in the process. The processes were compared with and without water recycle; savings of 70% and 43% in the annual fresh water consumption and the heating costs, respectively, were achieved. The optimal process complies with the Chilean environmental legislation limit of 0.05 g total nitrogen/L.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Annual Loan Cost Rates L Appendix L to Part 226 Banks and Banking FEDERAL RESERVE SYSTEM (CONTINUED) BOARD OF GOVERNORS OF THE FEDERAL RESERVE SYSTEM TRUTH IN LENDING (REGULATION Z) Pt. 226, App. L Appendix L to Part 226—Assumed Loan Periods for Computations of Total Annual Loan Cost Rates (a) Required...
Menon, J; Mishra, P
2018-04-01
We determined incremental health care resource utilization, incremental health care expenditures, incremental absenteeism, and incremental absenteeism costs associated with osteoarthritis. Medical Expenditure Panel Survey (MEPS) for 2011 was used as data source. Individuals 18 years or older and employed during 2011 were eligible for inclusion in the sample for analyses. Individuals with osteoarthritis were identified based on ICD-9-CM codes. Incremental health care resource utilization included annual hospitalization, hospital days, emergency room visits and outpatient visits. Incremental health expenditures included annual inpatient, outpatient, emergency room, medications, miscellaneous and annual total expenditures. Of the total sample, 1354 were diagnosed with osteoarthritis, and compared to non osteoarthritis individuals. Incremental resource utilization, expenditures, absenteeism and absenteeism costs were estimated using regression models, adjusting for age, gender, sex, region, marital status, insurance coverage, comorbidities, anxiety, asthma, hypertension and hyperlipidemia. Regression models revealed incremental mean annual resource use associated with osteoarthritis of 0.07 hospitalizations, equal to 70 additional hospitalizations per 100 osteoarthritic patients annually, and 3.63 outpatient visits, equal to 363 additional visits per 100 osteoarthritic patients annually. Mean annual incremental total expenditures associated with osteoarthritis were $2046. Annually, mean incremental expenditures were largest for inpatient expenditures at $826, followed by mean incremental outpatient expenditures of $659, and mean incremental medication expenditures of $325. Mean annual incremental absenteeism was 2.2 days and mean annual incremental absenteeism costs were $715.74. Total direct expenditures were estimated at $41.7 billion. Osteoarthritis was associated with significant incremental health care resource utilization, expenditures, absenteeism and absenteeism costs. Copyright © 2017 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ene, D.; Andersson, K.; Jensen, M.
The European Spallation Source (ESS) will produce tritium via spallation and activation processes during operational activities. Within the location of ESS facility in Lund, Sweden site it is mandatory to demonstrate that the management strategy of the produced tritium ensures the compliance with the country regulation criteria. The aim of this paper is to give an overview of the different aspects of the tritium management in ESS facility. Besides the design parameter study of the helium coolant purification system of the target the consequences of the tritium releasing into the environment were also analyzed. Calculations show that the annual releasemore » of tritium during the normal operations represents a small fraction from the estimated total dose. However, more refined calculations of migration of activated-groundwater should be performed for higher hydraulic conductivities, with the availability of the results on soil examinations. With the assumption of 100% release of tritium to the atmosphere during the occurring of the extreme accidents, it was found as well that the total dose complies with the constraint. (authors)« less
Code of Federal Regulations, 2011 CFR
2011-04-01
... maintenance assessment rate for the irrigation facility servicing my farm unit? 171.500 Section 171.500 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER IRRIGATION OPERATION AND... annual operation and maintenance assessment rate for the irrigation facility servicing my farm unit? (a...
Mean annual, seasonal, and monthly precipitation and runoff in Arkansas, 1951-2011
Pugh, Aaron L.; Westerman, Drew A.
2014-01-01
This report describes long-term annual, seasonal, and monthly means for precipitation and runoff in Arkansas for the period from 1951 through 2011. Precipitation means were estimated using data from the Parameter-elevation Regressions on Independent Slopes Model database; while total runoff, groundwater runoff, and surface runoff means were estimated using data from 123 active and inactive U.S. Geological Survey continuous-record streamflow-gaging stations located in Arkansas and surrounding States. Annual precipitation in Arkansas for the period from 1951 through 2011 had a mean of 49.8 inches. Of the six physiographic sections in Arkansas, the Ouachita Mountains had the largest mean annual precipitation at 53.0 inches, while the Springfield-Salem plateaus had the smallest mean annual precipitation at 45.5 inches. The mean annual total runoff for Arkansas was 17.8 inches. The Ouachita Mountains had the largest mean annual total runoff at 20.4 inches, while the Springfield-Salem plateaus had the smallest mean annual total runoff at 15.0 inches. Runoff is diminished during the dry season, which is attributed to increased losses from evapotranspiration, consumptive uses including irrigation, and increased withdrawals for public and private water supplies. The decline in runoff during the dry season is observed across the State in all physiographic sections. Spatial results for precipitation and runoff are presented in a series of maps that are available for download from the publication Web page in georeferenced raster formats.
Optimization of conventional water treatment plant using dynamic programming.
Mostafa, Khezri Seyed; Bahareh, Ghafari; Elahe, Dadvar; Pegah, Dadras
2015-12-01
In this research, the mathematical models, indicating the capability of various units, such as rapid mixing, coagulation and flocculation, sedimentation, and the rapid sand filtration are used. Moreover, cost functions were used for the formulation of conventional water and wastewater treatment plant by applying Clark's formula (Clark, 1982). Also, by applying dynamic programming algorithm, it is easy to design a conventional treatment system with minimal cost. The application of the model for a case reduced the annual cost. This reduction was approximately in the range of 4.5-9.5% considering variable limitations. Sensitivity analysis and prediction of system's feedbacks were performed for different alterations in proportion from parameters optimized amounts. The results indicated (1) that the objective function is more sensitive to design flow rate (Q), (2) the variations in the alum dosage (A), and (3) the sand filter head loss (H). Increasing the inflow by 20%, the total annual cost would increase to about 12.6%, while 20% reduction in inflow leads to 15.2% decrease in the total annual cost. Similarly, 20% increase in alum dosage causes 7.1% increase in the total annual cost, while 20% decrease results in 7.9% decrease in the total annual cost. Furthermore, the pressure decrease causes 2.95 and 3.39% increase and decrease in total annual cost of treatment plants. © The Author(s) 2013.
16 CFR 801.11 - Annual net sales and total assets.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Annual net sales and total assets. 801.11 Section 801.11 Commercial Practices FEDERAL TRADE COMMISSION RULES, REGULATIONS, STATEMENTS AND... person; and (2) The total assets of a person shall be as stated on the last regularly prepared balance...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-07
... for the first year to convert systems and conduct training. Estimated Total Annual Burden: National... 124,832 burden hours for the first year to convert systems and conduct training. Total: 571,302 burden... 188 burden hours for the first year to convert systems and conduct training. Estimated Total Annual...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-29
... under the Resource Conservation and recovery Act (RCRA); employees working at routine hazardous waste... 10.69 hours per response. Burden means the total time, effort, or financial resources expended by...: Annually. Estimated Total Average Number of Responses for Each Respondent: 1. Estimated Total Annual Hour...
Duncan, Stephen T; Jacobs, Cale A; Christensen, Christian P; Nunley, Ryan M; Macaulay, William B
2017-04-01
The Center for Medicare and Medicaid Services (CMS) has proposed a move to payment based on patient-reported outcomes (PROs), and failure to report on PROs will result in a penalty of 2% in 2016. However, the cost to the physician to collect PROs is not known. Using data from the 2013 Medical Group Management Association Compensation and Financial survey and Center for Medicare and Medicaid Services reimbursement, a calculation was performed to determine the cost to the physician to report on PROs for patients undergoing total knee arthroplasty and total hip arthroplasty. Using Medical Group Management Association and Medicare fee for service rates, calculations were performed based on an annual volume of 200 Medicare operative cases (125 total knee arthroplasties, 75 total hip arthroplasties) with 1000 new patients (level 4) and 2000 established patients (level 3) visits. A range of start-up and annual costs necessary to collect PROs including hardware, software, and personnel costs was calculated and then compared with the calculated 2% Medicare penalty for failing to report PROs in 2016. The cost to collect PROs ranged from $47,973 to $56,288 which far outweighed the penalty of $2954 in 2016 for failing to report these measures. With the move toward requiring surgeons to report PROs for reimbursement, the current financial model would prove to be cost prohibitive and the incentive to report PROs might be too costly to gain wide acceptance. Copyright © 2016 Elsevier Inc. All rights reserved.
1982-06-01
of hydrilla treated statewide was 12,570. MINOR PLANTS The District’s Minor Plant Program is directed to those plant species, introduced and native...use of several different EPA-registered herbicides selected for their activity against the target species. Total acreage of minor plants treated...Hence, the releases at Lake Alice probably played a minor role as a source of insects for the colonization of other sites. This was probably due to the
Complex analysis of energy efficiency in operated high-rise residential building: Case study
NASA Astrophysics Data System (ADS)
Korniyenko, Sergey
2018-03-01
Energy conservation and human thermal comfort enhancement in buildings is a topical issue of modern architecture and construction. The innovative solution of this problem makes it possible to enhance building ecological and maintenance safety, to reduce hydrocarbon fuel consumption, and to improve life standard of people. The requirements to increase of energy efficiency in buildings should be provided at all the stages of building's life cycle that is at the stage of design, construction and maintenance of buildings. The research purpose is complex analysis of energy efficiency in operated high-rise residential building. Many actions for building energy efficiency are realized according to the project; mainly it is the effective building envelope and engineering systems. Based on results of measurements the energy indicators of the building during annual period have been calculated. The main reason of increase in heat losses consists in the raised infiltration of external air in the building through a building envelope owing to the increased air permeability of windows and balcony doors (construction defects). Thermorenovation of the building based on ventilating and infiltration heat losses reduction through a building envelope allows reducing annual energy consumption. Energy efficiency assessment based on the total annual energy consumption of building, including energy indices for heating and a ventilation, hot water supply and electricity supply, in comparison with heating is more complete. The account of various components in building energy balance completely corresponds to modern direction of researches on energy conservation and thermal comfort enhancement in buildings.
78 FR 68023 - Annual Surveys in the Manufacturing Area
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-13
... Manufacturing Area. The 2014 Annual Surveys consist of the Annual Survey of Manufactures, the Business R&D and... economic census will be conducted for the year 2017. Annual Survey of Manufactures The Annual Survey of Manufactures collects industry statistics, such as total value of shipments, employment, payroll, workers...
DOT National Transportation Integrated Search
2007-01-01
In FY 2007, Amtrak earned approximately : $2.15 billion in total revenue and incurred about : $3.18 billion in expenses. Amtrak relies on an : annual federal appropriation, which in FY 2007 : totaled $1.294 billion, including $521 million in : operat...
Helicopter crashes related to oil and gas operations in the Gulf of Mexico.
Baker, Susan P; Shanahan, Dennis F; Haaland, Wren; Brady, Joanne E; Li, Guohua
2011-09-01
The hazards inherent in flight operations in the Gulf of Mexico prompted investigation of the number and circumstances of crashes related to oil and gas operations in the region. The National Transportation Safety Board (NTSB) database was queried for helicopter crashes during 1983 through 2009 related to Gulf of Mexico oil or gas production. The crashes were identified based on word searches confirmed by a narrative statement indicating that the flight was related to oil or gas operations. During 1983-2009, the NTSB recorded a total of 178 helicopter crashes related to oil and gas operations in the Gulf of Mexico, with an average of 6.6 crashes per year (5.6 annually during 1983-1999 vs. 8.2 during 2000-2009). The crashes resulted in a total of 139 fatalities, including 41 pilots. Mechanical failure was the most common precipitating factor, accounting for 68 crashes (38%). Bad weather led to 29 crashes (16%), in which 40% of the 139 deaths occurred. Pilot error was cited by the NTSB in 83 crashes (47%). After crashes or emergency landings on water, 15 helicopters sank when flotation devices were not activated automatically or by pilots. Mechanical failure, non-activation of flotation, and pilot error are major problems to be addressed if crashes and deaths in this lethal environment are to be reduced.
Improving operating room efficiency via an interprofessional approach.
Bender, Jeffrey S; Nicolescu, Teodora O; Hollingsworth, Susan B; Murer, Krystal; Wallace, Kristina R; Ertl, William J
2015-03-01
Third-party payer reimbursements will likely continue to decrease. Therefore, it is imperative for operating rooms (ORs), often a hospital's largest revenue source, to improve efficiency. We report the outcome after 3 years of a lean, Six Sigma program to improve OR utilization. In January 2011, our hospital system instituted a facility-wide approach to address the problem of OR efficiency. Interprofessional teams were formed to examine all aspects of OR use. An OR Governance Committee consisting of Department Chairs, nursing and senior administration oversaw the project. Outpatients' readiness on time for surgery increased from 59% to 95%, while first case on-time starts improved from 32% to 73%. Block utilization went from 68% to 74% and actual room utilization improved from 56% to 68%. The number of cases increased by 9%. Overtime went from 7% of total to 4%, so personnel costs decreased 14% despite 26% more employees. There was a reduction in annual voluntary OR staff turnover from 28% to 11%. Revenues increased more than 10% annually. A concerted effort to optimize OR performance resulted in marked improvements in access, overall case efficiency, staff satisfaction, and financial performance. Copyright © 2015 Elsevier Inc. All rights reserved.
Summary report of journal operations, 2012.
2013-01-01
Presents the summary reports of American Psychological Association journal operations (compiled from the 2012 annual reports of the Council of Editors and from Central Office records) and Division journal operations (compiled from the 2012 annual reports of the Division journal editors). The information provided includes number of manuscripts, printed pages, and print subscriptions per journal. (PsycINFO Database Record (c) 2013 APA, all rights reserved).
NASA Astrophysics Data System (ADS)
1982-04-01
The feasibility of a geothermal heating system at the Ojo Caliente Mineral Springs Co. was investigated. The geothermal energy will be used to preheat hot water for the laundry facilities and to heat the water for a two pipe fan coil heating system in the hotel. Present annual heating fuel costs of $11,218 for propane will be replaced by electricity to operate fans and pump at an annual cost of $2547, resulting in a net savings of $8671. Installation costs include $10,100 for a well system, $1400 for a laundry system, and $41,100 for a heating system. With the addition of a 10% design fee the total installation cost is $57,860. Ignoring escalating propane fuel prices, tax credits for energy conservation equipment, and potential funding from the State of New Mexico for a geothermal demonstration project, the simple economic payback period for this project is 6.7 years.
23 CFR 450.332 - Annual listing of obligated projects.
Code of Federal Regulations, 2010 CFR
2010-04-01
... calendar days following the end of the program year, the State, public transportation operator(s), and the... 450.332 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION PLANNING AND RESEARCH PLANNING ASSISTANCE AND STANDARDS Metropolitan Transportation Planning and Programming § 450.332 Annual...
National Urban Mass Transportation Statistics. Second Annual Report, Section 15 Reporting System
DOT National Transportation Integrated Search
1982-06-01
This report summarizes the financial and operating data submitted annually to the Urban Mass Transportation Administration (UMTA) by the nation's public transit operators, pursuant to Section 15 of the UMT Act of 1964, as amended. The report consists...
NASA Astrophysics Data System (ADS)
Izat Rashed, Ghamgeen
2018-03-01
This paper presented a way of obtaining certain operating rules on time steps for the management of a large reservoir operation with a peak hydropower plant associated to it. The rules were allowed to have the form of non-linear regression equations which link a decision variable (here the water volume in the reservoir at the end of the time step) by several parameters influencing it. This paper considered the Dokan hydroelectric development KR-Iraq, which operation data are available for. It was showing that both the monthly average inflows and the monthly power demands are random variables. A model of deterministic dynamic programming intending the minimization of the total amount of the squares differences between the demanded energy and the generated energy is run with a multitude of annual scenarios of inflows and monthly required energies. The operating rules achieved allow the efficient and safe management of the operation and it is quietly and accurately known the forecast of the inflow and of the energy demand on the next time step.
NASA Astrophysics Data System (ADS)
Rashed, G. I.
2018-02-01
This paper presented a way of obtaining certain operating rules on time steps for the management of a large reservoir operation with a peak hydropower plant associated to it. The rules were allowed to have the form of non-linear regression equations which link a decision variable (here the water volume in the reservoir at the end of the time step) by several parameters influencing it. This paper considered the Dokan hydroelectric development KR-Iraq, which operation data are available for. It was showing that both the monthly average inflows and the monthly power demands are random variables. A model of deterministic dynamic programming intending the minimization of the total amount of the squares differences between the demanded energy and the generated energy is run with a multitude of annual scenarios of inflows and monthly required energies. The operating rules achieved allow the efficient and safe management of the operation and it is quietly and accurately known the forecast of the inflow and of the energy demand on the next time step.
Seat Capacity Selection for an Advanced Short-Haul Aircraft Design
NASA Technical Reports Server (NTRS)
Marien, Ty V.
2016-01-01
A study was performed to determine the target seat capacity for a proposed advanced short-haul aircraft concept projected to enter the fleet by 2030. This analysis projected the potential demand in the U.S. for a short-haul aircraft using a transportation theory approach, rather than selecting a target seat capacity based on recent industry trends or current market demand. A transportation systems model was used to create a point-to-point network of short-haul trips and then predict the number of annual origin-destination trips on this network. Aircraft of varying seat capacities were used to meet the demand on this network, assuming a single aircraft type for the entire short-haul fleet. For each aircraft size, the ticket revenue and operational costs were used to calculate a total market profitability metric for all feasible flights. The different aircraft sizes were compared, based on this market profitability metric and also the total number of annual round trips and markets served. Sensitivity studies were also performed to determine the effect of changing the aircraft cruise speed and maximum trip length. Using this analysis, the advanced short-haul aircraft design team was able to select a target seat capacity for their design.
Improving Gas Furnace Performance: A Field and Laboratory Study at End of Life
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brand, L.; Yee, S.; Baker, J.
2015-02-01
In 2010, natural gas provided 54% of total residential space heating energy the U.S. on a source basis, or 3.5 Quadrillion Btu. Natural gas burned in furnaces accounted for 92% of that total, and boilers and other equipment made up the remainder. A better understanding of installed furnace performance is a key to energy savings for this significant energy usage. In this project, the U.S. Department of Energy Building America team Partnership for Advanced Residential Retrofit examined the impact that common installation practices and age-induced equipment degradation may have on the installed performance of natural gas furnaces over the lifemore » of the product, as measured by steady-state efficiency and annual efficiency. The team identified 12 furnaces of various ages and efficiencies that were operating in residential homes in the Des Moines, Iowa, metropolitan area and worked with a local heating, ventilation, and air conditioning contractor to retrieve furnaces and test them at the Gas Technology Institute laboratory for steady-state efficiency and annual efficiency. Prior to removal, system airflow, static pressure, equipment temperature rise, and flue loss measurements were recorded for each furnace as installed in the house.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-05
... rational manner, and to protect non-AFA participants in other fisheries. In addition, a voluntary civil... appeals. Estimated Total Annual Burden Hours: 470. Estimated Total Annual Cost to Public: $225. IV...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-18
... information is sent to the National Marine Fisheries Service (NMFS) for transmission to Russia. If Russian... Time per Response: 30 minutes. Estimated Total Annual Burden Hours: 1. Estimated Total Annual Cost to...
Specialization and the current practices of general surgeons.
Decker, Marquita R; Dodgion, Christopher M; Kwok, Alvin C; Hu, Yue-Yung; Havlena, Jeff A; Jiang, Wei; Lipsitz, Stuart R; Kent, K Craig; Greenberg, Caprice C
2014-01-01
The impact of specialization on the practice of general surgery has not been characterized. Our goal was to assess general surgeons' operative practices to inform surgical education and workforce planning. We examined the practices of general surgeons identified in the 2008 State Inpatient and Ambulatory Surgery Databases of the Healthcare Cost and Utilization Project for 3 US states. Operations were identified using ICD-9 and CPT codes linked to encrypted physician identifiers. For each surgeon, total operative volume and percentage of practice that made up their most common operation were calculated. Correlation was measured between general surgeons' case volume and the number of other specialists in a health service area. There were 1,075 general surgeons who performed 240,510 operations in 2008. The mean operative volume for each surgeon was 224 annual procedures. General surgeons performed an average of 23 different types of operations. For the majority of general surgeons, their most common procedure constituted no more than 30% of total practice. The most common operations, ranked by the frequency they appeared as general surgeons' top procedure, included cholecystectomy, colonoscopy, endoscopy, and skin excision. The proportion of general surgery practice composed of endoscopic procedures inversely correlated with the number of gastroenterologists in the health service area (rho = -0.50; p = 0.005). Despite trends toward specialization, the current practices of general surgeons remain heterogeneous. This indicates a continued demand for broad-based surgical education to allow future surgeons to tailor their practices to their environment. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
LDRD 2016 Annual Report: Laboratory Directed Research and Development Program Activities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hatton, D.
Each year, Brookhaven National Laboratory (BNL) is required to provide a program description and overview of its Laboratory Directed Research and Development Program (LDRD) to the Department of Energy (DOE) in accordance with DOE Order 413.2C dated October 22, 2015. This report provides a detailed look at the scientific and technical activities for each of the LDRD projects funded by BNL in FY 2016, as required. In FY 2016, the BNL LDRD Program funded 48 projects, 21 of which were new starts, at a total cost of $11.5M. The investments that BNL makes in its LDRD program support the Laboratory’smore » strategic goals. BNL has identified four Critical Outcomes that define the Laboratory’s scientific future and that will enable it to realize its overall vision. Two operational Critical Outcomes address essential operational support for that future: renewal of the BNL campus; and safe, efficient laboratory operations.« less
Dryer cuts fuel usage by equivalent of 6-million scf/yr
DOE Office of Scientific and Technical Information (OSTI.GOV)
List, K.H.; Powers, J.
Drying is an integral part of the production of ZnO pellets, a specific requirement for producing a uniform end product. The dryer has to be able to cure the product for a finite period at temperatures up to 500/sup 0/C in the same unit. Substantial savings have been realized because the dryer has enabled the user to optimize operating conditions. Continuous on-stream operations requiring minimum operator attendance, automatic controls, simplicity of design contruction, and the unit's ability to use waste heat also contribute to these savings. Gas exhausted from a nearby kiln provides the total heat requirement for the dryer.more » Positive delivery of the hot flue gas is assured by a blower and automatically controlled dampers. Annual fuel savings based on the use of waste heat, amounts to an equiv of 6 million scf of natural gas. 1 figure.« less
Saving tourists: the status of emergency medical services in California's National Parks.
Heggie, Travis W; Heggie, Tracey M
2009-01-01
Providing emergency medical services (EMS) in popular tourist destinations such as National Parks requires an understanding of the availability and demand for EMS. This study examines the EMS workload, EMS transportation methods, EMS funding, and EMS provider status in California's National Park Service units. A retrospective review of data from the 2005 Annual Emergency Medical Services Report for National Park Service (NPS) units in California. Sixteen NPS units in California reported EMS activity. EMS program funding and training costs totaled USD $1,071,022. During 2005 there were 84 reported fatalities, 910 trauma incidents, 663 non-cardiac medicals, 129 cardiac incidents, and 447 first aid incidents. Sequoia and Kings Canyon National Parks, Yosemite National Park, Golden Gate National Recreation Area, and Death Valley National Park accounted for 83% of the total EMS case workload. Ground transports accounted for 85% of all EMS transports and Emergency Medical Technicians with EMT-basic (EMT-B) training made up 76% of the total 373 EMS providers. Providing EMS for tourists can be a challenging task. As tourist endeavors increase globally and move into more remote environments, the level of EMS operations in California's NPS units can serve as a model for developing EMS operations serving tourist populations.
Facing the Recession: How Did Safety-Net Hospitals Fare Financially Compared with Their Peers?
Reiter, Kristin L; Jiang, H Joanna; Wang, Jia
2014-01-01
Objective To examine the effect of the recession on the financial performance of safety-net versus non-safety-net hospitals. Data Sources/Study Setting Agency for Healthcare Research and Quality Hospital Cost and Utilization Project State Inpatient Databases, Medicare Cost Reports, American Hospital Association Annual Survey, InterStudy, and Area Health Resource File. Study Design Retrospective, longitudinal panel of hospitals, 2007–2011. Safety-net hospitals were identified using percentage of patients who were Medicaid or uninsured. Generalized estimating equations were used to estimate average effects of the recession on hospital operating and total margins, revenues and expenses in each year, 2008–2011, comparing safety-net with non-safety-net hospitals. Data Collection/Extraction Methods 1,453 urban, nonfederal, general acute hospitals in 32 states with complete data. Principal Findings Safety-net hospitals, as identified in 2007, had lower operating and total margins. The gap in operating margin between safety-net and non-safety-net hospitals was sustained throughout the recession; however, total margin was more negatively affected for non-safety-net hospitals in 2008. Higher percentages of Medicaid and uninsured patients were associated with lower revenue in private hospitals in all years, and lower revenue and expenses in public hospitals in 2011. Conclusions Safety-net hospitals may not be disproportionately vulnerable to macro-economic fluctuations, but their significantly lower margins leave less financial cushion to weather sustained financial pressure. PMID:25220012
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 8 2010-01-01 2010-01-01 false Annual report. 924.34 Section 924.34 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... operations during the fiscal period; (b) an appraisal of the effect of such regulatory operations upon the...
Annual Report on Operations, 1999-2000.
ERIC Educational Resources Information Center
Australian National Training Authority, Brisbane.
This report, the Australian National Training Authority's (ANTA's) key reporting and accounting document, focuses on internal operations structured around the annual ANTA Plan and work priorities. A "Chairman's Comment" (Stuart Hornery) and "From the CEO's Desk" (Moira Scollay) precede an overview that provides a history of…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-29
... [email protected] . SUPPLEMENTARY INFORMATION: OMB Control Number: 3060-1060. Title: Wireless E911....C. sections 1, and 4(i). Total Annual Burden: 38 hours. Total Annual Cost: N/A. Privacy Act Impact...
Code of Federal Regulations, 2012 CFR
2012-04-01
... 25 Indians 1 2012-04-01 2011-04-01 true How does BIA calculate my annual operation and maintenance assessment if supplemental water is available on the irrigation facility servicing my farm unit? 171.510 Section 171.510 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER IRRIGATION OPERATION AND MAINTENANCE Financial...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 25 Indians 1 2010-04-01 2010-04-01 false How does BIA calculate my annual operation and maintenance assessment if supplemental water is available on the irrigation facility servicing my farm unit? 171.510 Section 171.510 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER IRRIGATION OPERATION AND MAINTENANCE Financial...
Code of Federal Regulations, 2011 CFR
2011-04-01
... 25 Indians 1 2011-04-01 2011-04-01 false How does BIA calculate my annual operation and maintenance assessment if supplemental water is available on the irrigation facility servicing my farm unit? 171.510 Section 171.510 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER IRRIGATION OPERATION AND MAINTENANCE Financial...
Walla Walla River Fish Passage Operations Program, 2004-2005 Annual Report.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bronson, James P.; Duke, Bill B.
2006-02-01
In the late 1990s, the Confederated Tribes of the Umatilla Indian Reservation, Oregon Department of Fish and Wildlife, and Washington Department of Fish and Wildlife, along with many other agencies, began implementing fisheries restoration activities in the Walla Walla Basin. An integral part of these efforts is to alleviate the inadequate fish migration conditions in the basin. The migration concerns are being addressed by removing diversion structures, constructing fish passage facilities, implementing minimum instream flow requirements, and providing trap and haul efforts when needed. The objective of the Walla Walla River Fish Passage Operations Project is to increase the survivalmore » of migrating adult and juvenile salmonids in the Walla Walla River basin. The project is responsible for coordinating operation and maintenance of ladders, screen sites, bypasses, trap facilities, and transportation equipment. In addition, the project provides technical input on passage criteria and passage and trapping facility design and operation. Operation of the various passage facilities and passage criteria guidelines are outlined in an annual operations plan that the project develops. During the 2004-2005 project year, there were 590 adult summer steelhead, 31 summer steelhead kelts (Oncorhynchus mykiss), 70 adult bull trout (Salvelinus confluentus); 80 adult and 1 jack spring Chinook (O. tshawytscha) enumerated at the Nursery Bridge Dam fishway video counting window between December 13, 2004, and June 16, 2005. Summer steelhead and spring chinook were observed moving upstream while bull trout were observed moving both upstream and downstream of the facility. In addition, the old ladder trap was operated by ODFW in order to enumerate fish passage. Of the total, 143 adult summer steelhead and 15 summer steelhead kelts were enumerated at the west ladder at Nursery Bridge Dam during the video efforts between February 4 and May 23, 2005. Operation of the Little Walla Walla River juvenile trap for trap and haul purposes was not necessary this year.« less
NASA Astrophysics Data System (ADS)
Meehan, Jennifer; Fulgham, Jared; Tobiska, W. Kent
2012-07-01
How can we continue to advance the space weather operational community from lessons already learned when it comes to data reliability, maintainability, accessibility, dependability, safety, and quality? How can we make space weather more easily accessible to each other and outside users? Representatives from operational, commercial, academic, and government organizations weighed in on these important questions at the second annual Space Weather Community Operations Workshop, held 22-23 March 2012 in Park City, Utah, with the unofficial workshop motto being Don’t Reinvent the Wheel.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-27
... Reports for Gas Pipeline Operators AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No... (OMB) Control No. 2137-0522, titled ``Incident and Annual Reports for Gas Pipeline Operators.'' PHMSA...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 36 Parks, Forests, and Public Property 3 2014-07-01 2014-07-01 false Annual report. 901.5 Section... CORPORATION § 901.5 Annual report. The Executive Director shall prepare annually a comprehensive and detailed report of the Corporation's operations, activities, and accomplishments for the review of the Board of...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false Annual report. 901.5 Section... CORPORATION § 901.5 Annual report. The Executive Director shall prepare annually a comprehensive and detailed report of the Corporation's operations, activities, and accomplishments for the review of the Board of...
36 CFR § 901.5 - Annual report.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 36 Parks, Forests, and Public Property 3 2013-07-01 2012-07-01 true Annual report. § 901.5... THE CORPORATION § 901.5 Annual report. The Executive Director shall prepare annually a comprehensive and detailed report of the Corporation's operations, activities, and accomplishments for the review of...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Annual report. 901.5 Section... CORPORATION § 901.5 Annual report. The Executive Director shall prepare annually a comprehensive and detailed report of the Corporation's operations, activities, and accomplishments for the review of the Board of...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 36 Parks, Forests, and Public Property 3 2012-07-01 2012-07-01 false Annual report. 901.5 Section... CORPORATION § 901.5 Annual report. The Executive Director shall prepare annually a comprehensive and detailed report of the Corporation's operations, activities, and accomplishments for the review of the Board of...
The Estimated Annual Cost of Uterine Leiomyomata in the United States
CARDOZO, Eden R.; CLARK, Andrew D.; BANKS, Nicole K.; HENNE, Melinda B.; STEGMANN, Barbara J.; SEGARS, James H.
2011-01-01
Objective To estimate the total annual societal cost of uterine fibroids in the United States, based on direct and indirect costs, including associated obstetric complications. Study Design A systematic review of the literature was conducted to estimate the number of women seeking treatment for symptomatic fibroids annually, the costs of medical and surgical treatment, work lost and obstetric complications attributable to fibroids. Total annual costs were converted to 2010 U.S. dollars. A sensitivity analysis was performed. Results The estimated annual direct costs (surgery, hospital admissions, outpatient visits, medications) were $4.1 to $9.4 billion. Estimated lost work costs ranged from $1.55 to $17.2 billion annually. Obstetric outcomes attributed to fibroids resulted in a cost of $238 million to $7.76 billion annually. Uterine fibroids were estimated to cost the US $5.9 to $34.4 billion annually. Conclusions Obstetric complications associated with fibroids contributed significantly to their economic burden. Lost work costs may account for the largest proportion of societal costs due to fibroids. PMID:22244472
78 FR 77550 - Proposed Agency Information Collection Activities; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-23
... Universe: 693 railroads. Frequency of Submission: On occasion. Reporting Burden: Total annual Average time per Total annual CFR Section Respondent universe responses response burden hours 237.3 Notifications... Universe: 685 railroads and 4 Locomotive Manufacturers. Frequency of Submission: On occasion. Reporting...
77 FR 68203 - Proposed Agency Information Collection Activities; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-15
.... Affected Public: Businesses. Respondent Universe: 5 Manufacturers. Total annual Average time per Total annual CFR section Respondent universe responses response burden hours 223.17--Identification of 4... Number(s): N/A. Affected Public: Railroad Employees. Respondent Universe: 40,000 Locomotive Engineers...
78 FR 32005 - Agency Information Collection Activities; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-28
...; SF-270. Affected Public: Businesses. Respondent Universe: 7 Railroads. Frequency of Submission: On occasion. Reporting Burden: Total annual Average time per Total annual Grant program Respondent universe... Number(s): N/A. Affected Public: States. Respondent Universe: 10 States. Frequency of Submission: On...
47 CFR 101.1417 - Annual report.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Annual report. Each MVDDS licensee shall file with the Broadband Division of the Wireless... the calendar year; (2) The total hours of transmission service rendered during the calendar year to all subscribers; (3) The total hours of transmission service rendered during the calendar year...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-29
... FEDERAL HOUSING FINANCE AGENCY [No. 2013-N-04] Notice of Annual Adjustment of the Cap on Average.... ACTION: Notice. SUMMARY: The Federal Housing Finance Agency (FHFA) has adjusted the cap on average total... Federal Deposit Insurance Corporation and that has average total assets below a statutory cap.\\2\\ The Bank...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-03
... FEDERAL HOUSING FINANCE AGENCY [No. 2010-N-01] Notice of Annual Adjustment of the Cap on Average.... ACTION: Notice. SUMMARY: The Federal Housing Finance Agency (FHFA) has adjusted the cap on average total... Deposit Insurance Corporation and that has average total assets below a statutory cap. See 12 U.S.C. 1422...
[Cost analysis for navigation in knee endoprosthetics].
Cerha, O; Kirschner, S; Günther, K-P; Lützner, J
2009-12-01
Total knee arthroplasty (TKA) is one of the most frequent procedures in orthopaedic surgery. The outcome depends on a range of factors including alignment of the leg and the positioning of the implant in addition to patient-associated factors. Computer-assisted navigation systems can improve the restoration of a neutral leg alignment. This procedure has been established especially in Europe and North America. The additional expenses are not reimbursed in the German DRG system (Diagnosis Related Groups). In the present study a cost analysis of computer-assisted TKA compared to the conventional technique was performed. The acquisition expenses of various navigation systems (5 and 10 year depreciation), annual costs for maintenance and software updates as well as the accompanying costs per operation (consumables, additional operating time) were considered. The additional operating time was determined on the basis of a meta-analysis according to the current literature. Situations with 25, 50, 100, 200 and 500 computer-assisted TKAs per year were simulated. The amount of the incremental costs of the computer-assisted TKA depends mainly on the annual volume and the additional operating time. A relevant decrease of the incremental costs was detected between 50 and 100 procedures per year. In a model with 100 computer-assisted TKAs per year an additional operating time of 14 mins and a 10 year depreciation of the investment costs, the incremental expenses amount to
Grazing and Land Management Strategies for Hardwood Rangelands
Melvin R. George
1991-01-01
Annual rangelands produce 84 percent of California's range forage which are used all year by sedentary ranching operations and seasonally by migratory operations. Environmental policy, energy and water costs may reduce traditional summer forage sources, resulting in increased grazing pressure on hardwood and annual rangelands. However, the landowner's...
The Universities Grants Commission. Annual Report, 1994-95.
ERIC Educational Resources Information Center
Manitoba Universities Grants Commission, Winnipeg.
This annual report describes the operations of the Manitoba Universities Grants Commission for the fiscal year 1994-95 with an audited balance sheet and statement of operating revenues and expenditures. The Commission advises the government on how much financial assistance should be given universities. It is also responsible for allocating funds…
75 FR 57866 - Farm Loan Programs Loan Making Activities
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-23
... majority of the commodities are not produced by the farming operation. Terms and Definitions Definitions... an annual analysis of the farming operation, doing an annual inspection of the farm, and preparing an... appraisal is Uniform Standards of Professional Appraisal Practice (USPAP) compliant, as proposed in Sec. 763...
Long-term dynamics of winter and summer annual communities in the Chihuahuan Desert
Guo, Q.; Brown, J.H.; Valone, T.J.
2002-01-01
Using 15 years of census data from permanent quadrats, this paper compared the characteristics and temporal dynamics of these two distinct, spatially coexistent but temporally segregated communities. Although the total number of summer annual species recorded during our 15 years observation was higher than winter annuals, the average number of species observed each year was higher in the winter community. The winter community exhibited lower temporal variation in total plant abundance and populations of individual species, lower species turnover rate and higher evenness than the summer community. The higher seasonal species diversity (i.e., number of species observed in each season) in winters rather than the overall special pool (over 15 yrs) may be responsible for the greater community stability of winter annuals. The difference in long-term community dynamics between the two communities of annuals plants are likely due to the differences in total species pool, life history traits (e.g., seed size), and seasonal climatic regimes.
28 CFR 16.208 - Annual report.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 28 Judicial Administration 1 2012-07-01 2012-07-01 false Annual report. 16.208 Section 16.208... Observation of Parole Commission Meetings § 16.208 Annual report. The Commission shall report annually to Congress regarding its compliance with Sunshine Act requirements, including a tabulation of the total...
28 CFR 16.208 - Annual report.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 28 Judicial Administration 1 2011-07-01 2011-07-01 false Annual report. 16.208 Section 16.208... Observation of Parole Commission Meetings § 16.208 Annual report. The Commission shall report annually to Congress regarding its compliance with Sunshine Act requirements, including a tabulation of the total...
28 CFR 16.208 - Annual report.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Annual report. 16.208 Section 16.208... Observation of Parole Commission Meetings § 16.208 Annual report. The Commission shall report annually to Congress regarding its compliance with Sunshine Act requirements, including a tabulation of the total...
28 CFR 16.208 - Annual report.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 28 Judicial Administration 1 2014-07-01 2014-07-01 false Annual report. 16.208 Section 16.208... Observation of Parole Commission Meetings § 16.208 Annual report. The Commission shall report annually to Congress regarding its compliance with Sunshine Act requirements, including a tabulation of the total...
21 CFR 1315.11 - Assessment of annual needs.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 9 2012-04-01 2012-04-01 false Assessment of annual needs. 1315.11 Section 1315... QUOTAS FOR EPHEDRINE, PSEUDOEPHEDRINE, AND PHENYLPROPANOLAMINE Assessment of Annual Needs § 1315.11 Assessment of annual needs. (a) The Administrator shall determine the total quantity of ephedrine...
21 CFR 1315.11 - Assessment of annual needs.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 9 2014-04-01 2014-04-01 false Assessment of annual needs. 1315.11 Section 1315... QUOTAS FOR EPHEDRINE, PSEUDOEPHEDRINE, AND PHENYLPROPANOLAMINE Assessment of Annual Needs § 1315.11 Assessment of annual needs. (a) The Administrator shall determine the total quantity of ephedrine...
21 CFR 1315.11 - Assessment of annual needs.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 9 2013-04-01 2013-04-01 false Assessment of annual needs. 1315.11 Section 1315... QUOTAS FOR EPHEDRINE, PSEUDOEPHEDRINE, AND PHENYLPROPANOLAMINE Assessment of Annual Needs § 1315.11 Assessment of annual needs. (a) The Administrator shall determine the total quantity of ephedrine...
21 CFR 1315.11 - Assessment of annual needs.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 9 2011-04-01 2011-04-01 false Assessment of annual needs. 1315.11 Section 1315... QUOTAS FOR EPHEDRINE, PSEUDOEPHEDRINE, AND PHENYLPROPANOLAMINE Assessment of Annual Needs § 1315.11 Assessment of annual needs. (a) The Administrator shall determine the total quantity of ephedrine...
Trends in hospital efficiency among metropolitan markets.
Wang, B B; Ozcan, Y A; Wan, T T; Harrison, J
1999-04-01
This study evaluates trends in efficiency among American hospital markets. A total of 6010 hospitals were identified for use in the analysis from the American Hospital Association's Annual Surveys for 1989 and 1993. Using data envelopment analysis (DEA), a longitudinal study of hospital efficiency was conducted on all 314 metropolitan markets in the United States. Results suggest that large hospital markets generally demonstrated higher inefficiency. The major inefficiencies exist in the availability of hospital services, the number of operating beds, the utilization of hospital staffing and operating expenses. Consequently, the large hospital market had a significant excess of health manpower that resulted in inefficiency that amounted to approximately $23 billion. From a policy perspective, this study has shed some light on the need to establish more specific policies to address inefficiency in the health care industry.
EU Funded Research Activities on NPPS Operational Safety
DOE Office of Scientific and Technical Information (OSTI.GOV)
Manolatos, P.; Van Goethem, G.
2002-07-01
The 5. framework programme (FP-5), the pluri-annual research programme of the European Union (EU), covers the period 1998-2002. Research on nuclear energy, fusion and fission, is covered by the EURATOM part of the FP-5. An overview of the Euratom's research on Nuclear Reactor Safety, managed by the DG-RTD of the European Commission (EC), is presented. This concerns 70 multi-partner projects of approximately euro 82.5 million total contract value that have been selected and co-financed during the period 1999-2001. They form the three clusters of projects dealing with the 'Operational Safety of Existing Installations'. 'Plant Life Extension and Management' (PLEM), 'Severemore » Accident Management' (SAM) and 'Evolutionary concepts' (EVOL). Emphasis is given here to the projects of the PLEM cluster. (authors)« less
76 FR 61347 - Notice of Proposed Information Collection Requests
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-04
..., middle and high schools). Total Estimated Number of Annual Responses: 413. Total Estimated Annual Burden..., middle and high schools where students achieve at high levels or where the achievement gap is narrowing... information technology. Dated: September 29, 2011. Darrin King, Director, Information Collection Clearance...
Estimation of salt loads for the Dolores River in the Paradox Valley, Colorado, 1980–2015
Mast, M. Alisa
2017-07-13
Regression models that relate total dissolved solids (TDS) concentrations to specific conductance were used to estimate salt loads for two sites on the Dolores River in the Paradox Valley in western Colorado. The salt-load estimates will be used by the Bureau of Reclamation to evaluate salt loading to the river coming from the Paradox Valley and the effect of the Paradox Valley Unit (PVU), a project designed to reduce the salinity of the Colorado River. A second-order polynomial provided the best fit of the discrete data for both sites on the river. The largest bias occurred in samples with elevated sulfate concentrations (greater than 500 milligrams per liter), which were associated with short-duration runoff events in late summer and fall. Comparison of regression models from a period of time before operation began at the PVU and three periods after operation began suggests the relation between TDS and specific conductance has not changed over time. Net salt gain through the Paradox Valley was estimated as the TDS load at the downstream site minus the load at the upstream site. The mean annual salt gain was 137,900 tons per year prior to operation of the PVU (1980–1993) and 43,300 tons per year after the PVU began operation (1997–2015). The difference in annual salt gain in the river between the pre-PVU and post-PVU periods was 94,600 tons per year, which represents a nearly 70 percent reduction in salt loading to the river.
40 CFR 75.74 - Annual and ozone season monitoring and reporting requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 17 2013-07-01 2013-07-01 false Annual and ozone season monitoring and... Annual and ozone season monitoring and reporting requirements. (a) Annual monitoring requirement. (1) The... during the entire calendar year. (b) Ozone season monitoring requirements. The owner or operator of an...
40 CFR 75.74 - Annual and ozone season monitoring and reporting requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 17 2012-07-01 2012-07-01 false Annual and ozone season monitoring and... Annual and ozone season monitoring and reporting requirements. (a) Annual monitoring requirement. (1) The... during the entire calendar year. (b) Ozone season monitoring requirements. The owner or operator of an...
40 CFR 75.74 - Annual and ozone season monitoring and reporting requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 16 2011-07-01 2011-07-01 false Annual and ozone season monitoring and... Annual and ozone season monitoring and reporting requirements. (a) Annual monitoring requirement. (1) The... during the entire calendar year. (b) Ozone season monitoring requirements. The owner or operator of an...
40 CFR 75.74 - Annual and ozone season monitoring and reporting requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Annual and ozone season monitoring and... Annual and ozone season monitoring and reporting requirements. (a) Annual monitoring requirement. (1) The... during the entire calendar year. (b) Ozone season monitoring requirements. The owner or operator of an...
Code of Federal Regulations, 2011 CFR
2011-10-01
... liquefied natural gas facilities: Annual report. 191.17 Section 191.17 Transportation Other Regulations...; gathering systems; and liquefied natural gas facilities: Annual report. (a) Transmission or Gathering. Each..., 2011. (b) LNG. Each operator of a liquefied natural gas facility must submit an annual report for that...
NASA Technical Reports Server (NTRS)
1991-01-01
More than 750 NASA, government, contractor, and academic representatives attended the Seventh Annual NASA/Contractors Conference on Quality and Productivity on October 12-13, 1990, in Grenelefe, Florida. The panel presentations and keynote speeches revolving around the theme of 'Total Quality Leadership" provided a solid base of understanding of the importance, benefits, and principles of total quality management. The implementation of these strategies is critical if we are to effectively pursue our mission of continuous quality improvement and reliability in our products, processes, and services. The annual NASA/contractors conferences serve as catalysts for achieving success in this mission.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-19
... FEDERAL HOUSING FINANCE AGENCY [No. 2011-N-01] Notice of Annual Adjustment of the Cap on Average.... ACTION: Notice. SUMMARY: The Federal Housing Finance Agency (FHFA) has adjusted the cap on average total... average total assets below a statutory cap. See 12 U.S.C. 1422(10)(A); 12 CFR 1263.1. The Bank Act was...
Foreword: Proceedings From the First Annual Lumbar Total Disc Replacement Summit.
Blumenthal, Scott; Buttermann, Glenn; Garcia, Rolando; Gornet, Matthew; Grunch, Betsy; Guyer, Richard; Janssen, Michael; Kimball, Brent; Lewis, Adam; Mesiwala, Ali; Miller, Lynn; Morreale, Joseph; Reed, William; Sandhu, Faheem; Shackleford, Ian; Yue, James; Zigler, Jack; OConnell, Brent; Ferko, Nicole; Hollmann, Sarah
2017-12-15
: This publication focuses on proceedings from the First Annual Lumbar Total Disc Replacement Summit, held October 25, 2016 in Boston, MA. The Summit brought together 17 thought leading surgeons who employed a modified-Delphi method to determine where consensus existed pertaining to the utilization of lumbar total disc replacement as a standard of care for a subpopulation of patients suffering from degenerative disc disease.
Economic Impacts from Indiana's First 1,000 Megawatts of Wind Power
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tegen, S.; Keyser, D.; Flores-Espino, F.
The magnitude of Indiana's available wind resource indicates that the development of wind power infrastructure has the potential to support millions of dollars of economic activity in the state. The Jobs and Economic Development Impact (JEDI) models, developed by the National Renewable Energy Laboratory, are tools used to estimate some of the economic impacts of energy projects at the state level. JEDI calculates results in the form of jobs, earnings, and economic output in three categories: project development and onsite labor, local revenue and supply chain, and induced impacts. According to this analysis, the first 1,000 MW of wind powermore » development in Indiana (projects built between 2008 and 2011): supported employment totaling more than 4,400 full-time-equivalent jobs in Indiana during the construction periods; supports approximately 260 ongoing Indiana jobs; supported nearly $570 million in economic activity for Indiana during the construction periods; supported and continues to support nearly $40 million in annual Indiana economic activity during the operating periods; generates more than $8 million in annual property taxes; generates nearly $4 million annually in income for Indiana landowners who lease their land for wind energy projects.« less
Biogeographical drivers of ragweed pollen concentrations in Europe
NASA Astrophysics Data System (ADS)
Matyasovszky, István; Makra, László; Tusnády, Gábor; Csépe, Zoltán; Nyúl, László G.; Chapman, Daniel S.; Sümeghy, Zoltán; Szűcs, Gábor; Páldy, Anna; Magyar, Donát; Mányoki, Gergely; Erostyák, János; Bodnár, Károly; Bergmann, Karl-Christian; Deák, Áron József; Thibaudon, Michel; Albertini, Roberto; Bonini, Maira; Šikoparija, Branko; Radišić, Predrag; Gehrig, Regula; Rybníček, Ondřej; Severova, Elena; Rodinkova, Victoria; Prikhodko, Alexander; Maleeva, Anna; Stjepanović, Barbara; Ianovici, Nicoleta; Berger, Uwe; Seliger, Andreja Kofol; Weryszko-Chmielewska, Elżbieta; Šaulienė, Ingrida; Shalaboda, Valentina; Yankova, Raina; Peternel, Renata; Ščevková, Jana; Bullock, James M.
2017-06-01
The drivers of spatial variation in ragweed pollen concentrations, contributing to severe allergic rhinitis and asthma, are poorly quantified. We analysed the spatiotemporal variability in 16-year (1995-2010) annual total (66 stations) and annual total (2010) (162 stations) ragweed pollen counts and 8 independent variables (start, end and duration of the ragweed pollen season, maximum daily and calendar day of the maximum daily ragweed pollen counts, last frost day in spring, first frost day in fall and duration of the frost-free period) for Europe (16 years, 1995-2010) as a function of geographical coordinates. Then annual total pollen counts, annual daily peak pollen counts and date of this peak were regressed against frost-related variables, daily mean temperatures and daily precipitation amounts. To achieve this, we assembled the largest ragweed pollen data set to date for Europe. The dependence of the annual total ragweed pollen counts and the eight independent variables against geographical coordinates clearly distinguishes the three highly infected areas: the Pannonian Plain, Western Lombardy and the Rhône-Alpes region. All the eight variables are sensitive to longitude through its temperature dependence. They are also sensitive to altitude, due to the progressively colder climate with increasing altitude. Both annual total pollen counts and the maximum daily pollen counts depend on the start and the duration of the ragweed pollen season. However, no significant changes were detected in either the eight independent variables as a function of increasing latitude. This is probably due to a mixed climate induced by strong geomorphological inhomogeneities in Europe.
Systems Engineering-Based Tool for Identifying Critical Research Systems
ERIC Educational Resources Information Center
Abbott, Rodman P.; Stracener, Jerrell
2016-01-01
This study investigates the relationship between the designated research project system independent variables of Labor, Travel, Equipment, and Contract total annual costs and the dependent variables of both the associated matching research project total annual academic publication output and thesis/dissertation number output. The Mahalanobis…
Code of Federal Regulations, 2010 CFR
2010-10-01
...-income consumers, schools and libraries, and heath care providers. The expense adjustment calculated... pursuant to § 36.612(a). (c) Until June 30, 2001, the annual amount of the total nationwide expense... calculated pursuant to this subpart F. The annual amount of the total nationwide loop cost expense adjustment...
DOT National Transportation Integrated Search
2009-01-01
The Ohio Department of Transportation is pleased to present the Federal : Fiscal Year (FFY) 2009 State Infrastructure Bank (SIB) Annual Financial : Report. : The portfolio of the FFY 2009 SIB had a total of nine loans totaling $9.0 : million and one ...
Runner, Michael S.; Turnipseed, D. Phil; Coupe, Richard H.
2002-01-01
Increased nutrient loading to the Gulf of Mexico from off-continent flux has been identified as contributing to the increase in the areal extent of the low dissolved-oxygen zone that develops annually off the Louisiana and Texas coast. The proximity of the Yazoo River Basin in northwestern Mississippi to the Gulf of Mexico, and the intensive agricultural activities in the basin have led to speculation that the Yazoo River Basin contributes a disproportionate amount of nitrogen and phosphorus to the Mississippi River and ultimately to the Gulf of Mexico. An empirical measurement of the flux of nitrogen and phosphorus from the Yazoo Basin has not been possible due to the hydrology of the lower Yazoo River Basin. Streamflow for the Yazoo River below Steele Bayou is affected by backwater from the Mississippi River. Flow at the gage is non-uniform and varying, with bi-directional and reverse flows possible. Streamflow was computed by using remote sensing and acoustic and conventional discharge and velocity measurement techniques. Streamflow from the Yazoo River for the 1996-2000 period accounted for 2.8 percent of the flow of the Mississippi River for the same period. Water samples from the Yazoo River were collected from February 1996 through December 2000 and were analyzed for total nitrogen, nitrate, total phosphorus, and orthophosphorus as part of the U.S. Geological Survey National Water-Quality Assessment Program. These data were used to compute annual loads of nitrogen and phosphorus discharged from the Yazoo River for the period 1996-2000. Annual loads of nitrogen and phosphorus were calculated by two methods. The first method used multivariate regression and the second method multiplied the mean annual concentration by the total annual flow. Load estimates based on the product of the mean annual concentration and the total annual flow were within the 95 percent confidence interval for the load calculated by multivariate regression in 10 of 20 cases. The Yazoo River loads, compared to average annual loads in the Mississippi River, indicated that the Yazoo River was contributing 1.4 percent of the total nitrogen load, 0.7 percent of the nitrate load, 3.4 percent of the total phosphorus load, and 1.6 percent of the orthophosphorus load during 1996 - 2000. The total nitrogen, nitrate, and orthophosphorus loads in the Yazoo River Basin were less than expected, whereas the total phosphorus load was slightly higher than expected based on discharge.
Agents and trends in health care workers' occupational asthma.
Walters, G I; Moore, V C; McGrath, E E; Burge, P S; Henneberger, P K
2013-10-01
There is a disproportionately high number of cases of work-related asthma occurring in health care occupations due to agents such as glutaraldehyde, latex and cleaning products. To understand the causes and measure trends over time of occupational asthma (OA) in health care workers (HCWs). We reviewed OA notifications from the Midland Thoracic Society's Surveillance Scheme of Occupational Asthma (SHIELD) database in the West Midlands, UK, from 1991 to 2011 and gathered data on occupation, causative agent and annual number of notifications. There were 182 cases of OA in HCWs (median annual notifications = 7; interquartile range [IQR] = 5-11), representing 5-19% of annual SHIELD notifications. The modal annual notification was 20 (in 1996); notifications have declined since then, in line with total SHIELD notifications. The majority of cases (136; 75%) occurred in nursing, operating theatre, endoscopy and radiology staff. The most frequently implicated agents were glutaraldehyde (n = 69), latex (n = 47) and cleaning products (n = 27), accounting for 79% of the 182 cases. Cleaning product-related OA was an emerging cause with 22 cases after 2001 and only 5 cases between 1991 and 2000. Control measures within the UK National Health Service have seen a decline in OA in HCWs due to latex and glutaraldehyde, though OA remains a problem amongst HCWs exposed to cleaning products. Continuing efforts are required to limit the number of cases in this employment sector.
Gebert, Warren A.; Rose, William J.; Garn, Herbert S.
2012-01-01
Few long-term data sets are available for evaluating the effects of urban stormwater-management practices. Over 30 years of data are available for evaluating the effectiveness of such practices by the city of Middleton, Wis. Analysis of streamflow and water-quality data collected on Pheasant Branch, demonstrates the relation between the changes in the watershed to the structural and nonstructural best management practices put in place during 1975-2008. A comparison of the data from Pheasant Branch with streamflow and water-quality data (suspended sediment and total phosphorus) collected at other nearby streams was made to assist in the determination of the possible causes of the changes in Pheasant Branch. Based on 34 years of streamflow data collected at the Pheasant Branch at Middleton streamflow-gaging station, flood peak discharges increased 37 percent for the 2-year flood and 83 percent for the 100-year flood. A comparison of data for the same period from an adjacent rural stream, Black Earth at Black Earth had a 43 percent increase in the 2-year flood peak discharge and a 140-percent increase in the 100-year flood peak discharge. Because the flood peak discharges on Pheasant Branch have not increased as much as Black Earth Creek it appears that the stormwater management practices have been successful in mitigating the effects of urbanization. Generally urbanization results in increased flood peak discharges. The overall increase in flood peak discharges seen in both streams probably is the result of the substantial increase in precipitation during the study period. Average annual runoff in Pheasant Branch has also been increasing due to increasing average annual precipitation and urbanization. The stormwater-management practices in Middleton have been successful in decreasing the suspended-sediment and total phosphorus loads to Lake Mendota from the Pheasant Branch watershed. These loads decreased in spite of increased annual runoff and flood peaks, which are often expected to produce higher sediment and phosphorus loads. The biggest decreases in sediment and phosphorus loads occurred after 2001 when a large detention pond, the Confluence Pond, began operation. Since 2001, the annual suspended-sediment load has decreased from 2,650 tons per year to 1,450 tons per year for a 45-percent decrease. The annual total phosphorus load has decreased from 12,200 pounds per year to 6,300 pounds per year for a 48-percent decrease. A comparison of Pheasant Branch at Middleton with two other streams, Spring Harbor Storm Sewer and Yahara River at Windsor, that drain into Lake Mendota shows that suspended-sediment and total phosphorus load decreases were greatest at Pheasant Branch at Middleton. Prior to the construction of the Confluence Pond, annual suspended-sediment yield and total phosphorus yield from Pheasant Branch watershed was the largest of the three watersheds. After 2001, suspended-sediment yield was greatest at Spring Harbor Storm Sewer, and lowest at Yahara at Windsor; annual total phosphorus yield was greater at Yahara River at Windsor than that of Pheasant Branch. The stormwater-quality plan for Middleton shows that the city has met the present State of Wisconsin Administrative Code chap. NR216/NR151 requirements of reducing total suspended solids by 20 percent for the developed area in Middleton. In addition, the city already has met the 40-percent reduction in total suspended solids required by 2013. Snow and ice melt runoff from road surfaces and parking lots following winter storms can effect water quality because the runoff contains varying amounts of road salt. To evaluate the effect of road deicing on stream water quality in Pheasant Branch, specific conductance and chloride were monitored during two winter seasons. The maximum estimated concentration of chloride during the monitoring period was 931 milligrams per liter, which exceeded the U.S. Environmental Protection Agency acute criterion of 860 milligrams per liter. Chloride concentrations exceeded the U.S. Environmental Protection Agency chronic criterion of 230 milligrams per liter for at least 10 days during February and March 2007 and for 45 days during the 2007-8 winter seasons. The total sodium chloride load for the monitoring period was 1,720 tons and the largest sodium chloride load occurred in March and April of each year.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Palchak, David; Cochran, Jaquelin; Deshmukh, Ranjit
The use of renewable energy (RE) sources, primarily wind and solar generation, is poised to grow significantly within the Indian power system. The Government of India has established a target of 175 gigawatts (GW) of installed RE capacity by 2022, including 60 GW of wind and 100 GW of solar, up from 29 GW wind and 9 GW solar at the beginning of 2017. Using advanced weather and power system modeling made for this project, the study team is able to explore operational impacts of meeting India’s RE targets and identify actions that may be favorable for integration. Our primarymore » tool is a detailed production cost model, which simulates optimal scheduling and dispatch of available generation in a future year (2022) by minimizing total production costs subject to physical, operational, and market constraints. Our team comprises a core group from the Power System Operation Corporation, Ltd. (POSOCO), which is the national grid operator (with representation from the National, Southern, and Western Regional Load Dispatch Centers) under Ministry of Power, National Renewable Energy Laboratory (NREL), and Lawrence Berkeley National Laboratory (Berkeley Lab), and a broader modeling team that includes Central Electricity Authority (CEA), POWERGRID (the central transmission utility, CTU), and State Load Dispatch Centers in Maharashtra, Gujarat, Tamil Nadu, Karnataka, Rajasthan, and Andhra Pradesh. Our model includes high-resolution wind and solar data (forecasts and actuals), unique properties for each generator, CEA/CTU’s anticipated buildout of the power system, and enforced state-to-state transmission flows. Assuming the fulfillment of current efforts to provide better access to the physical flexibility of the power system, we find that power system balancing with 100 GW of solar and 60 GW of wind is achievable at 15-minute operational timescales with minimal RE curtailment. This RE capacity meets 22% of total projected 2022 electricity consumption in India with annual RE curtailment of 1.4%, in line with experiences in other countries with significant RE penetrations (Bird et al. 2016). Changes to operational practice can further reduce the cost of operating the power system and reduce RE curtailment. Coordinating scheduling and dispatch over a broader area is the largest driver to reduce costs, saving INR 6300 crore (USD 980 million) annually when optimized regionally. Lowering minimum operating levels of coal plants (from 70% to 40%) is the biggest driver to reduce RE curtailment—from 3.5% down to 0.76%. In fact, this operating property is more influential than faster thermal generation ramp rates in lowering the projected levels of curtailment. While this study does not answer every question relevant to planning for India’s 2022 RE targets, it is an important step toward analyzing operational challenges and cost saving opportunities using state-of-the-art power system planning tools. Further analysis can build upon this basis to explore optimal renewable resource and intrastate transmission siting, system stability during contingencies, and the influence of total power system investment costs on customer tariffs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Palchak, David; Cochran, Jaquelin; Ehlen, Ali
The use of renewable energy (RE) sources, primarily wind and solar generation, is poised to grow significantly within the Indian power system. The Government of India has established a target of 175 gigawatts (GW) of installed RE capacity by 2022, including 60 GW of wind and 100 GW of solar, up from 29 GW wind and 9 GW solar at the beginning of 2017. Thanks to advanced weather and power system modeling made for this project, the study team is able to explore operational impacts of meeting India's RE targets and identify actions that may be favorable for integration. Ourmore » primary tool is a detailed production cost model, which simulates optimal scheduling and dispatch of available generation in a future year (2022) by minimizing total production costs subject to physical, operational, and market constraints. Our team comprises a core group from the Power System Operation Corporation, Ltd. (POSOCO), which is the national grid operator (with representation from the National, Southern, and Western Regional Load Dispatch Centers) under Ministry of Power, National Renewable Energy Laboratory (NREL), and Lawrence Berkeley National Laboratory (LBNL), and a broader modeling team that includes Central Electricity Authority (CEA), POWERGRID (the central transmission utility, CTU), and State Load Dispatch Centers in Maharashtra, Gujarat, Tamil Nadu, Karnataka, Rajasthan, and Andhra Pradesh. Our model includes high-resolution wind and solar data (forecasts and actuals), unique properties for each generator, CEA/CTU's anticipated buildout of the power system, and enforced state-to-state transmission flows. Assuming the fulfillment of current efforts to provide better access to the physical flexibility of the power system, we find that power system balancing with 100 GW of solar and 60 GW of wind is achievable at 15-minute operational timescales with minimal RE curtailment. This RE capacity meets 22% of total projected 2022 electricity consumption in India with annual RE curtailment of 1.4%, in line with experiences in other countries with significant RE penetrations (Bird et al. 2016). Changes to operational practice can further reduce the cost of operating the power system and reduce RE curtailment. Coordinating scheduling and dispatch over a broader area is the largest driver to reduce costs, saving INR 6300 crore (USD $920 million) annually when optimized regionally. Lowering minimum operating levels of coal plants (from 70% to 40%) is the biggest driver to reduce RE curtailment - from 3.5% down to 0.76%. In fact, this operating property is more influential than faster thermal generation ramp rates in lowering the projected levels of curtailment. While this study does not answer every question relevant to planning for India's 2022 RE targets, it is an important step toward analyzing operational challenges and cost saving opportunities using state-of-the-art power system planning tools. Further analysis can build upon this basis to explore optimal renewable resource and intrastate transmission siting, system stability during contingencies, and the influence of total power system investment costs on customer tariffs.« less
Spahr, Norman E.; Mueller, David K.; Wolock, David M.; Hitt, Kerie J.; Gronberg, JoAnn M.
2010-01-01
Data collected for the U.S. Geological Survey National Water-Quality Assessment program from 1992-2001 were used to investigate the relations between nutrient concentrations and nutrient sources, hydrology, and basin characteristics. Regression models were developed to estimate annual flow-weighted concentrations of total nitrogen and total phosphorus using explanatory variables derived from currently available national ancillary data. Different total-nitrogen regression models were used for agricultural (25 percent or more of basin area classified as agricultural land use) and nonagricultural basins. Atmospheric, fertilizer, and manure inputs of nitrogen, percent sand in soil, subsurface drainage, overland flow, mean annual precipitation, and percent undeveloped area were significant variables in the agricultural basin total nitrogen model. Significant explanatory variables in the nonagricultural total nitrogen model were total nonpoint-source nitrogen input (sum of nitrogen from manure, fertilizer, and atmospheric deposition), population density, mean annual runoff, and percent base flow. The concentrations of nutrients derived from regression (CONDOR) models were applied to drainage basins associated with the U.S. Environmental Protection Agency (USEPA) River Reach File (RF1) to predict flow-weighted mean annual total nitrogen concentrations for the conterminous United States. The majority of stream miles in the Nation have predicted concentrations less than 5 milligrams per liter. Concentrations greater than 5 milligrams per liter were predicted for a broad area extending from Ohio to eastern Nebraska, areas spatially associated with greater application of fertilizer and manure. Probabilities that mean annual total-nitrogen concentrations exceed the USEPA regional nutrient criteria were determined by incorporating model prediction uncertainty. In all nutrient regions where criteria have been established, there is at least a 50 percent probability of exceeding the criteria in more than half of the stream miles. Dividing calibration sites into agricultural and nonagricultural groups did not improve the explanatory capability for total phosphorus models. The group of explanatory variables that yielded the lowest model error for mean annual total phosphorus concentrations includes phosphorus input from manure, population density, amounts of range land and forest land, percent sand in soil, and percent base flow. However, the large unexplained variability and associated model error precluded the use of the total phosphorus model for nationwide extrapolations.
NASA Astrophysics Data System (ADS)
Forster, R. R.; Miege, C.; Box, J. E.; McConnell, J.; Spikes, V. B.; Burgess, E. W.
2010-12-01
The Greenland Ice Sheet plays an important role in Earth’s climate system evolution. The snow accumulation rate is the largest single mass budget term. With only 14% of the ice sheet area, Southeast Greenland contains the highest accumulation rates, accounting for one third of the total snow accumulation and annual variability. The high accumulation rates have made the region less desirable for long climate record ice cores and therefore, contain relatively very few in situ measurements to constrain the ice sheet mass budget. We present annual snow accumulation rates from the Arctic Circle Traverse 2010 (ACT-10). During April and May 2010 we acquired three 50 m firn cores connected by surface-based 400 MHz ground penetrating radar (GPR) in Southeast Greenland. The traverse repeated and extended the original Arctic Circle Traverse in 2004 (Spikes et al., 2004). Dating is achieved using geochemical analysis of the cores to identify isochronal layers detected by the GPR yielding annual accumulation estimates along the traverse between the core sites. The 300 km ACT-10 GPR snowmobile traverse extended the ACT-04 path 80 km to the lowest elevation core site at 1776 m. Meanwhile, airborne radars, operating as part of NASA’s Operation IceBridge also acquired data over the full length of the ACT-10 path, simultaneously with a portion of the traverse and within days for the remaining segments. The IceBridge and ACT-10 data are to be combined in a calibration effort such that snow accumulation rates may be mapped elsewhere in Greenland and even in Antarctica.
Roka, Fritz M.; Baucum, Leslie E.; Rice, Ronald W.; ...
2010-01-01
Sugarcane production in Florida is concentrated south and west of Lake Okeechobee and is grown on both muck and sand soils. During the 2008-2009 season, more than 12 million metric tons of sugarcane was harvested and supported important sugarcane milling and sugar refining operations located in southern Florida. Farms on muck soils account for 80% of Florida’s annual sugarcane crop, while farms on sand soils account for the remaining 20%. This paper compares revenues, production costs and net annual returns from two equally sized sugarcane farms (2,000 hectare) representing typical growing conditions on sand and muck soils. Sugarcane growers onmore » muck soils enjoy two distinct advantages over their counterparts farming sugarcane on sand soils. First, total farm revenues are higher because of greater yields and a higher percentage of land that can be grown for commercial harvest. Second, unit costs of production are lower due to the inherent organic matter in muck soils, allowing growers to apply substantially less quantities of fertilizers. Annual net returns to land, management and risk from growing sugarcane on muck soils are estimated to be 400 dollars/ha, more than five times higher than estimated net returns from growing sugarcane on sand soils (70 dollars/ha). Furthermore, while sugarcane production on sand soils is less profitable relative to muck soils, economic returns from sugarcane on sand soils are higher than from cattle operations, offer less risk than presently associated with citrus production, and occupy land area far beyond the capacity of the vegetable industry to absorb.« less
Torikai, J.D.
1996-01-01
This report describes the status of ground-water resources at U.S. Navy Support Facility, Diego Garcia. Data presented are from January 1994 through September 1996, with a focus on data from July through September 1996 (third quarter of 1996). A complete database of ground-water withdrawals and chloride-concentration records since 1985 is maintained by the U.S. Geological Survey. Total rainfall for the period July through September 1996 was 8.94 inches, which is 60 percent less than the mean rainfall of 22.23 inches for the period July through September. July and August are part of the annual dry season, while September is the start of the annual wet season. Ground-water withdrawal during July through September 1996 averaged 1,038,300 gallons per day. Withdrawal for the same 3 months in 1995 averaged 888,500 gallons per day. Ground-water withdrawals have steadily increased since about April 1995. At the end of September 1996, the chloride concentration of water from the elevated tanks at Cantonment and Air Operations were 68 and 150 milligrams per liter, respectively. The chloride concentration from all five production areas increased throughout the third quarter of 1996, and started the upward trend in about April 1995. Chloride concentration of ground water in monitoring wells at Cantonment and Air Operations also increased throughout the third quarter of 1996, with the largest increases from water in the deepest monitoring wells. Chloride concentrations have not been at this level since the dry season of 1994. A fuel-pipeline leak at Air Operations in May 1991 decreased total islandwide withdrawals by 15 percent. This lost pumping capacity is being offset by increased pumpage at Cantonment. Six wells do not contribute to the water supply because they are being used to hydraulically divert fuel migration away from water-supply wells by a program of ground-water withdrawal and injection.
Fuelwood discount store: a new concept in marketing firewood
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fowler, G.D.
1979-01-01
A wood yard selling split firewood has been developed in Glastonbury, Connecticut, in conjunction with a company which builds 18,000 All Nighter wood stoves annually. Investments required to begin the retailing operation for firewood included purchase of a LaFont firewood processor to produce at least 10,000 cords per year, and 5 1/2 acres of land with a six-foot high fence ($20,000) and a gravel surface. Total investment was $300,000. Wood will be sold for $59.00 per full cord. Cost will be calculated by weight of vehicles entering and leaving the yard.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-09
... Request; Direct Investment Surveys: BE-11, Annual Survey of U.S. Direct Investment Abroad AGENCY: Bureau... to Sarahelen Thompson, Acting Chief, Direct Investment Division (BE-50), Bureau of Economic Analysis.... Direct Investment Abroad (Form BE-11) obtains financial and operating data covering the operations of U.S...
36 CFR 9.4 - Surface disturbance moratorium.
Code of Federal Regulations, 2010 CFR
2010-07-01
... operations meets the applicable standard of approval of § 9.10(a)(1), he shall issue a permit allowing the... INTERIOR MINERALS MANAGEMENT Mining and Mining Claims § 9.4 Surface disturbance moratorium. (a) For a... maintain production at an annual rate not to exceed an average annual production level of said operations...
30 CFR 285.506 - What operating fees must I pay on a commercial lease?
Code of Federal Regulations, 2010 CFR
2010-07-01
...(annual operating fee) = M(nameplate capacity) * H(hours per year) * c(capacity factor) * P(power price... an annual payment; (4) c is the “capacity factor” representing the anticipated efficiency of the... wholesale electric power price expressed in dollars per megawatt hour, as provided in paragraph (c)(2) of...
40 CFR 63.7525 - What are my monitoring, installation, operation, and maintenance requirements?
Code of Federal Regulations, 2012 CFR
2012-07-01
... audit, and an annual zero alignment audit of each COMS. (6) You must operate and maintain each COMS... assessment, a quarterly performance audit, or an annual zero alignment audit. (7) You must determine and... control activities (including, as applicable, calibration checks and required zero and span adjustments...
40 CFR 63.7525 - What are my monitoring, installation, operation, and maintenance requirements?
Code of Federal Regulations, 2011 CFR
2011-07-01
... audit, and an annual zero alignment audit of each COMS. (6) You must operate and maintain each COMS... assessment, a quarterly performance audit, or an annual zero alignment audit. (7) You must determine and... control activities (including, as applicable, calibration checks and required zero and span adjustments...
Coming Up Short: 35th Annual M&O Cost Study
ERIC Educational Resources Information Center
Agron, Joe
2006-01-01
As the nation's school buildings age and deteriorate, spending on maintenance and operations (M&O) remains paltry, especially when compared with historical figures. This article presents the findings of "American School & University's" 35th annual Maintenance and Operations Cost Study. According to the M&O Cost Study, the median school district…
Further Evaluation of an Emperical Equation for Annual Total Evaporation
NASA Technical Reports Server (NTRS)
Choudhury, Bhaskar J.
1999-01-01
An empirical equation for annual total evaporation based on annual precipitation and net radiation was found to provide evaporation within 10% of the observed values at seven locations within temperate and tropical regions, but it overestimated evaporation by 90% at one location within the tundra region. A synthesis of observations at two other locations within the tundra region gives overestimates of about 65%. A general analysis of observed precipitation, net radiation, and runoff within the tundra region shows that the empirical equation is generally biased to overestimate annual evaporation within the tundra region. A theoretical analysis is being done to understand the reason behind this bias.
The Regional Differences of Gpp Estimation by Solar Induced Fluorescence
NASA Astrophysics Data System (ADS)
Wang, X.; Lu, S.
2018-04-01
Estimating gross primary productivity (GPP) at large spatial scales is important for studying the global carbon cycle and global climate change. In this study, the relationship between solar-induced chlorophyll fluorescence (SIF) and GPP is analysed in different levels of annual average temperature and annual total precipitation respectively using simple linear regression analysis. The results showed high correlation between SIF and GPP, when the area satisfied annual average temperature in the range of -5 °C to 15 °C and the annual total precipitation is higher than 200 mm. These results can provide a basis for future estimation of GPP research.
Wang, Zhi Peng; Zhang, Xian Zhou; He, Yong Tao; Li, Meng; Shi, Pei Li; Zu, Jia Xing; Niu, Ben
2018-01-01
Precipitation change is an important factor in the inter-annual variation of grassland growth on the Tibetan Plateau. The total amount, distribution pattern and concentration time are three basic characteristics of precipitation change. The temporal and spatial characteristics of precipitation change were analyzed based on climate data of 145 meteorological stations on the Tibetan Plateau and nearby areas from 2000 to 2015. The total precipitation amount was characterized by annual precipitation, distribution pattern of precipitation during the year was characterized by improved precipitation concentration index (PCI), and precipitation centroid (PC) was defined to indicate the change in precipitation concentrated time. To better illustrate the response of grassland to precipitation change, vegetation growth status was characterized by the maximum value of normalized difference vegetation index (NDVI max ). Results indicated that the annual precipitation and PCI had an apparent gradient across the whole plateau and the latest PC occurred in the southern plateau. NDVI max of alpine shrub grassland was significantly correlated with the change of PCI,increased with even distribution of precipitation during growth period, and limited by the total annual precipitation. Alpine meadow did not show significantly correlations with these three indices. The inter-annual variability of NDVI max of steppe was controlled by both PCI and PC. NDVI max of alpine desert grassland was mainly controlled by annual precipitation. In addition to annual total amount of precipitation, the distribution characteristics of precipitation should be further considered when the influence of precipitation change on different types of vegetation on the Qinghai Tibet Plateau was studied.
Southeastern Power Administration 2012 Annual Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2012-01-01
Dear Secretary Moniz: I am pleased to submit Southeastern Power Administration’s (Southeastern) fiscal year (FY) 2012 Annual Report for your review. This report reflects our agency’s programs, accomplishments, operational, and financial activities for the 12-month period beginning October 1, 2011, and ending September 30, 2012. This past year, Southeastern marketed approximately 5.4 billion kilowatt-hours of energy to 487 wholesale customers in 10 southeastern states. Revenues from the sale of this power totaled about $263 million. With the financial assistance and support of Southeastern’s customers, funding for capitalized equipment purchases and replacements at hydroelectric facilities operated by the U.S. Army Corpsmore » of Engineers (Corps) continued in FY 2012. Currently, there are more than 214 customers participating in funding infrastructure renewal efforts of powerplants feeding the Georgia-Alabama-South Carolina, Kerr-Philpott, and Cumberland Systems. This funding, which totaled more than $71 million, provided much needed repairs and maintenance for aging projects in Southeastern’s marketing area. Drought conditions continued in the southeastern region of the United States this past year, particularly in the Savannah River Basin. Lack of rainfall strained our natural and financial resources. Power purchases for FY 2012 in the Georgia-Alabama-South Carolina System totaled approximately $29 million. About $8 million of this amount was for replacement power, which is purchased only during adverse water conditions in order to meet Southeastern’s customer contract requirements. Southeastern’s goal is to maximize the benefits of our region’s water resources. Competing uses of these resources will present another challenging year for Southeastern’s employees. With the cooperation and communication among the Department of Energy (DOE), preference customers, and Corps, I am certain Southeastern is positioned to meet these challenges in the future. We are committed to providing reliable hydroelectric power to preference customers, which ultimately serve more than 12 million consumers in the southeast. Sincerely, Kenneth E. Legg Administrator« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Habte, Aron M; Sengupta, Manajit
It is essential to apply a traceable and standard approach to determine the uncertainty of solar resource data. Solar resource data are used for all phases of solar energy conversion projects, from the conceptual phase to routine solar power plant operation, and to determine performance guarantees of solar energy conversion systems. These guarantees are based on the available solar resource derived from a measurement station or modeled data set such as the National Solar Radiation Database (NSRDB). Therefore, quantifying the uncertainty of these data sets provides confidence to financiers, developers, and site operators of solar energy conversion systems and ultimatelymore » reduces deployment costs. In this study, we implemented the Guide to the Expression of Uncertainty in Measurement (GUM) 1 to quantify the overall uncertainty of the NSRDB data. First, we start with quantifying measurement uncertainty, then we determine each uncertainty statistic of the NSRDB data, and we combine them using the root-sum-of-the-squares method. The statistics were derived by comparing the NSRDB data to the seven measurement stations from the National Oceanic and Atmospheric Administration's Surface Radiation Budget Network, National Renewable Energy Laboratory's Solar Radiation Research Laboratory, and the Atmospheric Radiation Measurement program's Southern Great Plains Central Facility, in Billings, Oklahoma. The evaluation was conducted for hourly values, daily totals, monthly mean daily totals, and annual mean monthly mean daily totals. Varying time averages assist to capture the temporal uncertainty of the specific modeled solar resource data required for each phase of a solar energy project; some phases require higher temporal resolution than others. Overall, by including the uncertainty of measurements of solar radiation made at ground stations, bias, and root mean square error, the NSRDB data demonstrated expanded uncertainty of 17 percent - 29 percent on hourly and an approximate 5 percent - 8 percent annual bases.« less
Steuer, Jeffrey S.; Hall, David W.; Fitzgerald, Sharon A.
1999-01-01
The distribution and transport of polychlorinated biphenyl (PCB) congeners was determined at two sites on Pine Creek and at the Hayton Millpond on the South Branch of the Manitowoc River in Wisconsin during 1993-95. PCB congener compositions were analyzed in the operationally defined dissolved phase, suspended particulate phase, and surficial bed sediments (0-2 centimeters depth) several times throughout the sampling period. The relative abundances of PCB congeners in the suspended particles and in surficial bed sediments were generally similar to each other and to a known Aroclor mixture (1254). PCB congener composites in the operationally defined dissolved phase were higher in the less chlorinated congeners in keeping with their lower hydrophobicity and higher predicted solubility relative to the more chlorinated congeners. Suspended particle-associated PCB concentrations exhibited two patterns: (1) a cyclical variation in spring and summer associated with algal growth, and (2) episodic increases associated with resuspension of bed sediments during storms. Computed total suspended-solids (TSS) load at the millpond outlet was as high as 920 tons over a 3-month period (June 30-Sept. 30, 1993). Annual TSS loads for the following two years were lower, 610 and 500 tons, respectively. Total PCB concentrations in the water column varied at the millpond outlet, ranging from 34 to 302 nanograms per liter, whereas concentrations upstream on Pine Creek were as high as 563 nanograms per liter. In general, 70 percent of PCB's in the water column were associated with suspended particles. The total congener-summation PCB (SPCB) concentration regression equation incorporated the universal soil loss coefficent to represent erosion of assumedly PCB-free sediment from fields upstream from the millpond. The SPCB load based on the regression relation was 3.4 kilograms during the 3-month high-flow interval (June 30-Sept. 30, 1993). Subsequent annual SPCB loads for the next two water years were 3.5 and 2.3 kilograms, respectively.
78 FR 5866 - Pipeline Safety: Annual Reports and Validation
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-28
... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket ID PHMSA-2012-0319] Pipeline Safety: Annual Reports and Validation AGENCY: Pipeline and Hazardous Materials... 2012 gas transmission and gathering annual reports, remind pipeline owners and operators to validate...
Are high penetrations of commercial cogeneration good for society?
NASA Astrophysics Data System (ADS)
Keen, Jeremy F.; Apt, Jay
2016-12-01
Low natural gas prices, market reports and evidence from New York State suggest that the number of commercial combined heat and power (CHP) installations in the United States will increase by 2%-9% annually over the next decade. We investigate how increasing commercial CHP penetrations may affect net emissions, the distribution network, and total system energy costs. We constructed an integrated planning and operations model that maximizes owner profit through sizing and operation of CHP on a realistic distribution feeder in New York. We find that a greater penetration of CHP reduces both total system energy costs and network congestion. Commercial buildings often have low and inconsistent heat loads, which can cause low fuel utilization efficiencies, low CHP rates-of-return and diminishing avoided emissions as CHP penetration increases. In the northeast, without policy intervention, a 5% penetration of small commercially owned CHP would increase CO2 emissions by 2% relative to the bulk power grid. Low emission CHP installations can be encouraged with incentives that promote CHP operation only during times of high heat loads. Time-varying rates, such as time-of-day and seasonal rates, are one option and were shown to reduce customer emissions without reducing profits. In contrast, natural gas rate discounts, a common incentive for industrial CHP in some states, can encourage CHP operation during low heat loads and thus increase emissions.
77 FR 14598 - Proposed Information Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-12
... Respondent: 15 hours 12 minutes. Estimated Total Annual Burden Hours: 7,560,000. Title: Information Return of..., 35 minutes. Estimated Total Annual Burden Hours: 158,800. Title: Information Return for Real Estate... may not receive a Form 1099 and other information necessary to prepare their tax return in a timely...
33rd Annual Official Education Construction Report
ERIC Educational Resources Information Center
Agron, Joe
2007-01-01
Construction spending by education institutions topped $36 billion in 2006. While strong by historical standards, it represents the third consecutive year that total spending on construction dropped from the year before. According to the "American School & University" 33rd annual Official Education Construction Report, total spending on new,…
DOT National Transportation Integrated Search
2008-01-01
The Ohio Department of Transportation is pleased to present the Federal Fiscal Year (FFY) 2008 State Infrastructure Bank (SIB) Annual Financial Report. The portfolio of the FFY 2008 SIB had a total of five loans totaling $22.1 million. Since the begi...
75 FR 52934 - Notice of Submission for OMB Review
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-30
.... OMB Control Number: 1840-0564. Agency Form Number(s): N/A. Frequency of Responses: Annually. Affected Public: Not-for-profit institutions. Total Estimated Number of Annual Responses: 500. Total Estimated... at http://www.reginfo.gov/public/do/PRAMain or from the Department's website at http://edicsweb.ed...
Torikai, J.D.
1996-01-01
This report describes the status of ground-water resources at U.S. Navy Support Facility, Diego Garcia. Data presented are from January 1994 through March 1996, with a focus on data from January through March 1996 (first quarter of 1996). A complete database of ground-water withdrawals and chloride-concentration records since 1985 is maintained by the U.S. Geological Survey. Cumulative rainfall for January through March 1996 was about 30 inches, which is 9 percent less than the mean cumulative rainfall of about 33 inches for January through March. The period January through February is the end of the annual wet season, while March marks the start of the annual dry season. Ground-water withdrawal during January through March 1996 averaged 970,300 gallons per day. Withdrawal for the same 3 months in 1995 averaged 894,600 gallons per day. With- drawal patterns during the first quarter of 1996 did not change significantly since 1991, with the Cantonment and Air Operations areas supplying about 99 percent of total islandwide pumpage. At the end of March 1996, the chloride concentration of water from the elevated tanks at Cantonment and Air Operations were 47 and 80 milligrams per liter, respectively. The chloride data from all five production areas showed no significant upward or downward trends throughout the first quarter of 1996. Potable levels of chloride concentrations have been maintained by adjusting individual pumping rates, and also because of the absence of long-term droughts. Chloride concentration of ground water in monitoring wells at Cantonment and Air Operations also showed no significant trends throughout the first quarter of 1996. Chloride concentrations have been about the same since the last quarter of 1995. A fuel-pipeline leak at Air Operations in May 1991 decreased total islandwide withdrawals by 15 percent. This lost pumping capacity is being offset by increased pumpage at Cantonment. Six wells do not contribute to the water supply because they are being used to hydraulically divert fuel migration away from water-supply wells by a program of ground-water withdrawal and injection.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Compliance Requirements § 60.4895 By what date must I conduct annual air pollution control device inspections and make any necessary repairs? (a) You must conduct an annual inspection of each air pollution... following the previous annual air pollution control device inspection. (b) Within 10 operating days...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Compliance Requirements § 60.4895 By what date must I conduct annual air pollution control device inspections and make any necessary repairs? (a) You must conduct an annual inspection of each air pollution... following the previous annual air pollution control device inspection. (b) Within 10 operating days...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Compliance Requirements § 60.4895 By what date must I conduct annual air pollution control device inspections and make any necessary repairs? (a) You must conduct an annual inspection of each air pollution... following the previous annual air pollution control device inspection. (b) Within 10 operating days...
24 CFR 883.604 - Maximum annual commitment and project account.
Code of Federal Regulations, 2011 CFR
2011-04-01
... annual commitment. The maximum annual contribution that may be contracted for in the ACC is the total of... annual commitment exceeds the amount actually paid out under the ACC each year. Payments will be made... specifically approved by the Secretary. (2) Whenever a HUD-approved estimate of required payments under the ACC...
24 CFR 883.604 - Maximum annual commitment and project account.
Code of Federal Regulations, 2010 CFR
2010-04-01
... annual commitment. The maximum annual contribution that may be contracted for in the ACC is the total of... annual commitment exceeds the amount actually paid out under the ACC each year. Payments will be made... specifically approved by the Secretary. (2) Whenever a HUD-approved estimate of required payments under the ACC...
49 CFR 219.800 - Annual reports.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false Annual reports. 219.800 Section 219.800 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Annual Report § 219.800 Annual reports. (a) Each railroad that has a total of 400,000 or more...
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
2009-01-18
The 2008 DOE Vehicle Technologies Program Annual Merit Review was held February 25-28, 2008 in Bethesda, Maryland. The review encompassed all of the work done by the Vehicle Technologies Program: a total of 280 individual activities were reviewed, by a total of just over 100 reviewers. A total of 1,908 individual review responses were received for the technical reviews, and an additional 29 individual review responses were received for the plenary session review.
Solar Activity, Ultraviolet Radiation and Consequences in Birds in Mexico City, 2001- 2002
NASA Astrophysics Data System (ADS)
Valdes, M.; Velasco, V.
2008-12-01
Anomalous behavior in commercial and pet birds in Mexico City was reported during 2002 by veterinarians at the Universidad Nacional Autonoma de Mexico. This was attributed to variations in the surrounding luminosity. The solar components, direct, diffuse, global, ultraviolet band A and B, as well as some meteorological parameters, temperature, relative humidity, and precipitation, were then analyzed at the Solar Radiation Laboratory. Although the total annual radiance of the previously mentioned radiation components did not show important changes, ultraviolet Band-B solar radiation did vary significantly. During 2001 the total annual irradiance , 61.05 Hjcm² to 58.32 Hjcm², was 1.6 standard deviations lower than one year later, in 2002 and increased above the mean total annual irradiance, to 65.75 Hjcm², 2.04 standard deviations, giving a total of 3.73 standard deviations for 2001-2002. Since these differences did not show up clearly in the other solar radiation components, daily extra-atmosphere irradiance was analyzed and used to calculate the total annual extra-atmosphere irradiance, which showed a descent for 2001. Our conclusions imply that Ultraviolet Band-B solar radiation is representative of solar activity and has an important impact on commercial activity related with birds.
Development of an Electric Motor Powered Low Cost Coconut Deshelling Machine
NASA Astrophysics Data System (ADS)
Mondal, Imdadul Hoque; Prasanna Kumar, G. V.
2016-06-01
An electric motor powered coconut deshelling machine was developed in line with the commercially available unit, but with slight modifications. The machine worked on the principle that the coconut shell can be caused to fail in shear and compressive forces. It consisted of a toothed wheel, a deshelling rod, an electric motor, and a compound chain drive. A bevelled 16 teeth sprocket with 18 mm pitch was used as the toothed wheel. Mild steel round bar of 18 mm diameter was used as the deshelling rod. The sharp edge tip of the deshelling rod was inserted below the shell to apply shear force on the shell, and the fruit was tilted toward the rotary toothed wheel to apply the compressive force on the shell. The speed of rotation of the toothed wheel was set at 34 ± 2 rpm. The output capacity of the machine was found to be 24 coconuts/h with 95 % of the total time effectively used for deshelling. The labour requirement was found to be 43 man-h/1000 nuts. About 13 % of the kernels got scraped and about 7 % got sliced during the operation. The developed coconut deshelling machine was recommended for the minimum annual use of 200 h or deshelling of 4700 coconuts per year. The cost of operation for 200 h of annual use was found to be about ` 47/h. The developed machine was found to be simple, easy to operate, energy efficient, safe and reduce drudgery involved in deshelling by conventional methods.
Bang, Ki Moon; Mazurek, Jacek M; Wood, John M; White, Gretchen E; Hendricks, Scott A; Weston, Ainsley
2015-02-13
Silicosis is a preventable occupational lung disease caused by the inhalation of respirable crystalline silica dust and can progress to respiratory failure and death. No effective specific treatment for silicosis is available; patients are provided supportive care, and some patients may be considered for lung transplantation. Chronic silicosis can develop or progress even after occupational exposure has ceased. The number of deaths from silicosis declined from 1,065 in 1968 to 165 in 2004. Hazardous occupational exposures to silica dust have long been known to occur in a variety of industrial operations, including mining, quarrying, sandblasting, rock drilling, road construction, pottery making, stone masonry, and tunneling operations. Recently, hazardous silica exposures have been newly documented during hydraulic fracturing of gas and oil wells and during fabrication and installation of engineered stone countertops. To describe temporal trends in silicosis mortality in the United States, CDC analyzed annual multiple cause-of-death data for 2001-2010 for decedents aged ≥15 years. During 2001-2010, a total of 1,437 decedents had silicosis coded as an underlying or contributing cause of death. The annual number of silicosis deaths declined from 164 (death rate† = 0.74 per 1 million population) in 2001 to 101 (0.39 per 1 million) in 2010 (p = 0.002). Because of new operations and tasks placing workers at risk for silicosis, efforts to limit workplace exposure to crystalline silica need to be maintained.
Seasonal and intradiurnal variation of airborne pollen concentrations in Bodrum, SW Turkey.
Tosunoglu, Aycan; Bicakci, Adem
2015-04-01
An aeropalynological study was performed in Bodrum, the famous tourism center in southwestern Turkey with a Hirst-type volumetric 7-day pollen and spore trap for 2 years (2007-2008). In Bodrum, 25,099 pollen grains as a mean value belonging to 41 taxa were recorded annually during the study period, and pollen grains from woody plant taxa had the largest atmospheric contribution of 86.99% and 24 taxa. However, 17 herbaceous plant taxa constituted 12.82% of the annual total pollen count, and 0.19% were unidentified. An average annual pollen index of 22.66% was recorded in March, despite differences from year to year. The highest pollen variability of 34 taxa was recorded in April and May. Predominant pollen types belonged to Cupressaceae/Taxaceae (42.73%), Quercus (15.95%), Pinus (9.78%), Olea europaea (9.04%), Poaceae (5.50%), Betula (1.82%), Pistacia (1.74%), Morus (1.72%), Urticaceae (1.46%), and Plantago (1.28%) and generated 91.03 of the annual total. In total, 32.59% of the mean annual total pollen index was recorded in the morning, and less pollen was recorded in the evening (18.71%). Maximum pollen concentration was recorded between 11:00 and 12:00 a.m.
Analysis of 2000 Financial Forecasts and Annual Operating Statements. Report.
ERIC Educational Resources Information Center
Higher Education Funding Council for England, Bristol.
This report provides a summary of financial projections for the higher education sector in England covering 1999-2000 to 2003-2004 and a summary of the sector's annual operating statements for 1999-2000 and 2000-2001. It is based on information provided by higher education institutions in July 2000. These forecasts were prepared before the outcome…
Different incidences of knee arthroplasty in the Nordic countries.
NiemeläInen, Mika J; MäKelä, Keijo T; Robertsson, Otto; W-Dahl, Annette; Furnes, Ove; Fenstad, Anne M; Pedersen, Alma B; Schrøder, Henrik M; Huhtala, Heini; Eskelinen, Antti
2017-04-01
Background and purpose - The annual number of total knee arthroplasties (TKAs) has increased worldwide in recent years. To make projections regarding future needs for primaries and revisions, additional knowledge is important. We analyzed and compared the incidences among 4 Nordic countries Patients and methods - Using Nordic Arthroplasty Register Association (NARA) data from 4 countries, we analyzed differences between age and sex groups. We included patients over 30 years of age who were operated with TKA or unicompartmental knee arthroplasty (UKA) during the period 1997-2012. The negative binomial regression model was used to analyze changes in general trends and in sex and age groups. Results - The average annual increase in the incidence of TKA was statistically significant in all countries. The incidence of TKA was higher in women than in men in all 4 countries. It was highest in Finland in patients aged 65 years or more. At the end of the study period in 2012, Finland's total incidence was double that of Norway, 1.3 times that of Sweden and 1.4 times that of Denmark. The incidence was lowest in the youngest age groups (< 65 years) in all 4 countries. The proportional increase in incidence was highest in patients who were younger than 65 years. Interpretation - The incidence of knee arthroplasty steadily increased in the 4 countries over the study period. The differences between the countries were considerable, with the highest incidence in Finland. Patients aged 65 years or more contributed to most of the total incidence of knee arthroplasty.
Geothermal Heat Pump System for New Student Housing Project at the University at Albany Main Campus
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lnu, Indumathi
University at Albany successfully designed, constructed and is operating a new student housing building that utilizes ground source heat pump (GSHP) for heating and cooling the entire 191,500SF building. The installed system consists of a well field with 150 bores, 450 feet deep and (189) terminal heat pump units for a total capacity of 358 Tons cooling and 4,300 MBtu/h heating. The building opened in Fall 2012. The annual energy use and cost intensity of the building, after the changes made during the first 2 years’ of operation is 57kBtu/SF/Year and $1.30/SF/Year respectively. This is approximately 50% lower than themore » other residential quads on campus, despite the fact that the quads are not air-conditioned. The total project cost from design through 3-years of operations is approximately $6 Million, out of which $5.7 Million is for construction of the GSHP system including the well field. The University received a $2.78 Million grant from the Department of Energy. The estimated utility cost savings, compared to a baseline building with conventional HVAC system, is approximately $185,000. The estimated simple payback, after grant incentives, is 15 years. Additionally, the project has created 8.5FTE equivalent jobs.« less
Adams, D. Briane; Bauer, Daniel P.; Dale, Robert H.; Steele, Timothy Doak
1983-01-01
Development of coal resources and associated economy is accelerating in the Yampa River basin in northwestern Colorado and south-central Wyoming. Increased use of the water resources of the area will have a direct impact on their quantity and quality. As part of 18 surface-water projects, 35 reservoirs have been proposed with a combined total storage of 2.18 million acre-feet, 41% greater than the mean annual outflow from the basin. Three computer models were used to demonstrate methods of evaluating future impacts of reservoir development in the Yampa River basin. Four different reservoir configurations were used to simulate the effects of different degrees of proposed reservoir development. A multireservoir-flow model included both within-basin and transmountain diversions. Simulations indicated that in many cases diversion amounts would not be available for either type of diversion. A corresponding frequency analysis of reservoir storage levels indicated that most reservoirs would be operating with small percentages of total capacities and generally with less than 20% of conservation-pool volumes. Simulations using a dissolved-solids model indicated that extensive reservoir development could increase average annual concentrations at most locations. Simulations using a single-reservoir model indicated no significant occurrence of water-temperature stratification in most reservoirs due to limited reservoir storage. (USGS)
Determining national greenhouse gas emissions from waste-to-energy using the Balance Method.
Schwarzböck, Therese; Rechberger, Helmut; Cencic, Oliver; Fellner, Johann
2016-03-01
Different directives of the European Union require operators of waste-to-energy (WTE) plants to report the amount of electricity that is produced from biomass in the waste feed, as well as the amount of fossil CO2 emissions generated by the combustion of fossil waste materials. This paper describes the application of the Balance Method for determining the overall amount of fossil and thus climate relevant CO2 emissions from waste incineration in Austria. The results of 10 Austrian WTE plants (annual waste throughput of around 2,300 kt) demonstrate large seasonal variations in the specific fossil CO2 emissions of the plants as well as large differences between the facilities (annual means range from 32±2 to 51±3 kg CO(2,foss)/GJ heating value). An overall amount of around 924 kt/yr of fossil CO2 for all 10 WTE plants is determined. In comparison biogenic (climate neutral) CO2 emissions amount to 1,187 kt/yr, which corresponds to 56% of the total CO2 emissions from waste incineration. The total energy input via waste feed to the 10 facilities is about 22,500 TJ/yr, of which around 48% can be assigned to biogenic and thus renewable sources. Copyright © 2016 Elsevier Ltd. All rights reserved.
Torikai, J.D.
1995-01-01
This report contains hydrologic and climatic data that describe the status of ground-water resources at U.S. Navy Support Facility, Diego Garcia. Data presented are from January 1992 through December 1994. This report concentrates on data from October through December 1994, and references previous data from 1992 through 1994. Cumulative rainfall for October through December 1994 was 55 inches which is higher than the mean cumulative rainfall of about 31 inches for the same 3 months. Total rainfall for 1994 was 131 inches which is 24 percent higher than the mean annual rainfall of 106 inches. In com- parison, total rainfall in 1992 and 1993 were 93 inches and 95 inches, respectively. Ground-water withdrawal during October through December 1994 averaged 903,000 gallons per day, while the annual withdrawal in 1994 was 942,700 gallons per day. Annual withdrawals in 1992 and 1993 averaged 935,900 gallons per day and 953,800 gallons per day, respectively. At the end of December 1994, the chloride concentration of the composite water supply was 28 milligrams per liter, well below the 250 milligrams per liter secondary drinking-water standard established by the U.S. Environmental Protection Agency. Chloride concentrations of the composite water supply from October through December 1994 ranged between 28 and 86 milligrams per liter. Chloride concentration of ground water in monitoring wells at Cantonment and Air Operations decreased in November and December, and seems to have leveled off by the end of the year. Although chloride concen- trations have decreased during the fourth quarter of 1994, there has been a general trend of increasing chloride concentrations in the deeper monitoring wells since the 1992 dry season, which began in March 1992. A fuel leak at Air Operations caused the shutdown of ten wells in May 1991. Four of the wells resumed pumping for water-supply purposes in April 1992. The remaining six wells are being used to hydraulically contain and divert fuel migration by recirculating 150,000 gallons of water each day.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-12
... in the stress test, for each quarter of the planning horizon, aggregate losses, pre-provision net... Company-Run Stress Test Requirements for Banking Organizations With Total Consolidated Assets Over $10... regulatory agency to conduct stress tests on an annual basis. The Board is adopting this final rule to...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-05
... submitted to the Office of Management and Budget (OMB) for review and approval. Proposed Collection: The... Investigators, 1; Trainees, 1; Average burden hours per response: 30 minutes; and Estimated total annual burden hours requested: 250 hours. The total annualized cost to respondents (calculated as the number of...
78 FR 76312 - Information Collection Approved by the Office of Management and Budget (OMB)
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-17
...). Total Annual Burden: 7,924 hours for in-house work for large incumbent local exchange carriers. Total.... OMB Approval Date: July 31, 2013. OMB Expiration Date: July 31, 2016. Title: Study Area Boundary Data...,443 responses. Estimated Time per Response: 26 hours. Frequency of Response: Annually if changes to...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-03
... form relates to a budget or estimate of the legal fees, costs, and expenses that outside counsel would... average number of respondents, burden, and total annual cost appear below. The estimated number of... and the representations and certifications form. The NCUA estimated the total annual cost by...
2012 DOE Vehicle Technologies Program Annual Merit Review
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
The 2012 DOE Hydrogen Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting was held May 14-18, 2012 in Crystal City, Virginia. The review encompassed all of the work done by the Hydrogen Program and the Vehicle Technologies Program: a total of 309 individual activities were reviewed for Vehicle Technologies, by a total of 189 reviewers. A total of 1,473 individual review responses were received for the technical reviews.
Annual environmental monitoring report of the Lawrence Berkeley Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schleimer, G.E.
1983-04-01
In order to establish whether LBL research activities produces any impact on the population surrounding the Laboratory, a program of environmental air and water sampling and continuous radiation monitoring was carried on throughout the year. For 1982, as in the previous several years, doses attributable to LBL radiological operations were a small fraction of the relevant radiation protection guidelines (RPG). The maximum perimeter dose equivalent was less than or equal to 24.0 mrem (the 1982 dose equivalent measured at the Building 88 monitoring station B-13A, about 5% of the RPG). The total population dose equivalent attributable to LBL operations duringmore » 1982 was less than or equal to 16 man-rem, about 0.002% of the RPG of 170 mrem/person to a suitable sample of the population.« less
Samad, Lubna; Iqbal, Mehreen; Tariq, Ahson; Shahzad, Wasif; Khan, Aamir J
2015-01-01
Equitable access to surgical care is necessary for improving global health. We report on the performance, financial sustainability, and policy impact of a free-of-cost multispecialty surgical delivery program in Karachi, Pakistan built upon local private philanthropy. We evaluated trends in surgical service delivery, expenditures, and philanthropic donations from Indus Hospital's first 5 years of operation (2007-2012), projected these over the hospital's current expansion phase, compared these to publicly accessible records of other philanthropic hospitals providing surgical care, and documented the government's evolving policies toward this model. Between 2007 and 2012, Indus Hospital treated 40,012 in-patients free of cost, 33,606 (84 %) of them for surgical procedures. Surgical procedures increased fivefold to 9,478 during 2011-2012 from 1,838 during 2007-2008. Bed occupancy increased to 91 % from 65 % over the same period. External surgical missions accounted for less than 0.5 % of patients served. Ninety-eight percent (98 %) of all philanthropic donations--totaling USD 26.6 million over 2007-2012--were locally generated. Zakat (obligatory annual religious alms in the Islamic faith) constituted 34 % of all donations, followed by unrestricted funds (24 %) and donations-in-kind (24 %), buildings (12 %), grants (5 %), and return on investments (1 %). Overall, donations received between 2007 and 2012 increased sevenfold, with Zakat increasing 12-fold. During 2013-2014, the Government of Pakistan provided land lease and annual operational grants totaling USD 9 million. Local philanthropy can sustain and grow the provision of free, high-quality surgical care in low-income settings, and encourage the development of hybrid government-philanthropic models of surgical care.
2011-01-01
control number. 1. REPORT DATE 2011 2. REPORT TYPE 3. DATES COVERED 00-00-2011 to 00-00-2011 4. TITLE AND SUBTITLE SERC 2011 Annual Report...2 SERC Operational Accomplishments .................................................................4 An Evolving Role for the... SERC Research Council ................................5 Systems Engineering for an Agile and Lean World ....................................6 Annual
77 FR 27039 - Combined Notice of Filings
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-08
...: Black Marlin Pipeline Company. Description: Black Marlin Pipeline Company submits Annual Imbalance Cash... Transmission LLC submits Annual Imbalance Cash-out Report. Filed Date: 4/26/12. Accession Number: 20120426-5286...: Annual Report of Operational Imbalances for 2011 of Cameron Interstate Pipeline, LLC. Filed Date: 4/27/12...
NASA Astrophysics Data System (ADS)
Li, Xin; Babovic, Vladan
2017-04-01
Observed studies on inter-annual variation of precipitation provide insight into the response of precipitation to anthropogenic climate change and natural climate variability. Inter-annual variation of precipitation results from the concurrent variations of precipitation frequency and intensity, understanding of the relative importance of frequency and intensity in the variability of precipitation can help fathom its changing properties. Investigation of the long-term changes of precipitation schemes has been extensively carried out in many regions across the world, however, detailed studies of the relative importance of precipitation frequency and intensity in inter-annual variation of precipitation are still limited, especially in the tropics. Therefore, this study presents a comprehensive framework to investigate the inter-annual variation of precipitation and the dominance of precipitation frequency and intensity in a tropical urban city-state, Singapore, based on long-term (1980-2013) daily precipitation series from 22 rain gauges. First, an iterative Mann-Kendall trend test method is applied to detect long-term trends in precipitation total, frequency and intensity at both annual and seasonal time scales. Then, the relative importance of precipitation frequency and intensity in inducing the inter-annual variation of wet-day precipitation total is analyzed using a dominance analysis method based on linear regression. The results show statistically significant upward trends in wet-day precipitation total, frequency and intensity at annual time scale, however, these trends are not evident during the monsoon seasons. The inter-annual variation of wet-day precipitation is mainly dominated by precipitation intensity for most of the stations at annual time scale and during the Northeast monsoon season. However, during the Southwest monsoon season, the inter-annual variation of wet-day precipitation is mainly dominated by precipitation frequency. These results have implications for water resources management practices in Singapore.
Cloth media filtration and membrane microfiltration: serial operation.
Tooker, Nicholas Brewster; Darby, Jeannie L
2007-02-01
A combined system comprised of a cloth media filter and a membrane microfilter operated in series was used to treat secondary effluent. The study objective was to investigate the effect of premembrane filtration on the maximum sustainable membrane flux, transmembrane pressure, and effluent quality. The maximum sustainable time-averaged flux under predefined operating conditions (i.e., 15-minute process cycle, 24-hour chemical cleaning cycle, and 30-day intensive cleaning cycle) was 127 L/m(2)x h. Typical flux rates for secondary effluent ranged from 40 to 55 L/m(2) x h. Effluent water quality from the combined system was high and independent of membrane flux and influent quality. Average membrane effluent water quality values were 0.04 NTU for turbidity and 1.4 mg/L for 5-day biochemical oxygen demand. Neither total nor fecal coliforms were detected. Based on the results presented herein, prefiltration would provide an annualized cost savings of approximately 12% over microfiltration alone for a 3.8 x 10(3) m(3)/d treatment facility.
Proceedings: Third Annual Workshop on Meteorological and Environmental Inputs to Aviation Systems
NASA Technical Reports Server (NTRS)
Camp, D. W. (Editor); Frost, W. (Editor)
1979-01-01
The proceedings of a workshop on meteorological and environmental inputs to aviation systems are reported. The major objectives of the workshop are to satisfy such needs of the sponsoring agencies as the expansion of our understanding and knowledge of the interaction of the atmosphere with aviation systems, the better definition and implementation of services to operators, and the collection and interpretation of data for establishing operational criteria, relating the total meteorological inputs from the atmospheric sciences to the needs of aviation communities. The unique aspect of the workshop was the achievement of communication across the interface of the boundaries between pilots, meteorologists, training personnel, accident investigators, traffic controllers, flight operation personnel from military, civil, general aviation, and commercial interests alike. Representatives were in attendance from government, airlines, private agencies, aircraft manufacturers, Department of Defense, industries, research institutes, and universities. Full-length papers addressed the topics of training, flight operations, accident investigation, air traffic control, and airports. Winds and wind shear; icing and frost; atmospheric electricity and lightning; fog, visibility and ceilings; and turbulence were discussed.
Alternative Fuels Data Center: Maps and Data
-24960-10gn0o4 Annual Percent Growth of Vehicles in Operation Generated_thumb20160914-24960-10gn0o4 Last Annual Percent Growth of Vehicles in Operation 2010-2011 2011-2012 2012-2013 2013-2014 2014-2015 CNG States of America. Electric drive trains (EVs, Hydrogen, PHEVs and HEVs) experienced the greatest growth
Code of Federal Regulations, 2013 CFR
2013-01-01
... internal tolerances. (4) Engine mount—for cracks, looseness of mounting, and looseness of engine to mount... aircraft and aircraft engine. (b) Each person performing an annual or 100-hour inspection shall inspect...) improper operation. (5) Flight and engine controls—for improper installation and improper operation. (6...
Code of Federal Regulations, 2014 CFR
2014-01-01
... internal tolerances. (4) Engine mount—for cracks, looseness of mounting, and looseness of engine to mount... aircraft and aircraft engine. (b) Each person performing an annual or 100-hour inspection shall inspect...) improper operation. (5) Flight and engine controls—for improper installation and improper operation. (6...
Code of Federal Regulations, 2011 CFR
2011-01-01
... internal tolerances. (4) Engine mount—for cracks, looseness of mounting, and looseness of engine to mount... aircraft and aircraft engine. (b) Each person performing an annual or 100-hour inspection shall inspect...) improper operation. (5) Flight and engine controls—for improper installation and improper operation. (6...
Code of Federal Regulations, 2012 CFR
2012-01-01
... internal tolerances. (4) Engine mount—for cracks, looseness of mounting, and looseness of engine to mount... aircraft and aircraft engine. (b) Each person performing an annual or 100-hour inspection shall inspect...) improper operation. (5) Flight and engine controls—for improper installation and improper operation. (6...
Determinants of isocyanate exposures in auto body repair and refinishing shops.
Woskie, S R; Sparer, J; Gore, R J; Stowe, M; Bello, D; Liu, Y; Youngs, F; Redlich, C; Eisen, E; Cullen, M
2004-07-01
As part of the Survey of Painters and Repairers of Auto bodies by Yale (SPRAY), the determinants of isocyanate exposure in auto body repair shops were evaluated. Measurements (n = 380) of hexamethylene diisocyanate-based monomer and polyisocyanate and isophorone diisocyanate-based polyisocyanate were collected from 33 auto body shops. The median total reactive isocyanate concentrations expressed as mass concentration of the NCO functional group were: 206 microg NCO/m3 for spray operations; 0.93 microg NCO/m3 for samples collected in the vicinity of spray operations done on the shop floor (near spray); 0.05 microg NCO/m3 for office or other shop areas adjacent to spray areas (workplace background); 0.17 microg NCO/m3 for paint mixing and gun cleaning operations (mixing); 0.27 microg NCO/m3 for sanding operations. Exposure determinants for the sample NCO mass load were identified using linear regression, tobit regression and logistic regression models. For spray samples in a spray booth the significant determinants were the number of milliliters of NCO applied, the gallons of clear coat used by the shop each month and the type of spray booth used (custom built crossdraft, prefabricated crossdraft or downdraft/semi-downdraft). For near spray (bystander) samples, outdoor temperature >65 degrees F (18 degrees C) and shop size >5000 feet2 (465 m2) were significant determinants of exposure levels. For workplace background samples the shop annual income was the most important determinant. For sanding samples, the shop annual income and outdoor temperature >65 degrees F (18 degrees C) were the most significant determinants. Identification of these key exposure determinants will be useful in targeting exposure evaluation and control efforts to reduce isocyanate exposures.
NASA Astrophysics Data System (ADS)
Geressu, Robel T.; Harou, Julien J.
2015-12-01
Multi-reservoir system planners should consider how new dams impact downstream reservoirs and the potential contribution of each component to coordinated management. We propose an optimized multi-criteria screening approach to identify best performing designs, i.e., the selection, size and operating rules of new reservoirs within multi-reservoir systems. Reservoir release operating rules and storage sizes are optimized concurrently for each separate infrastructure design under consideration. Outputs reveal system trade-offs using multi-dimensional scatter plots where each point represents an approximately Pareto-optimal design. The method is applied to proposed Blue Nile River reservoirs in Ethiopia, where trade-offs between total and firm energy output, aggregate storage and downstream irrigation and energy provision for the best performing designs are evaluated. This proof-of concept study shows that recommended Blue Nile system designs would depend on whether monthly firm energy or annual energy is prioritized. 39 TWh/yr of energy potential is available from the proposed Blue Nile reservoirs. The results show that depending on the amount of energy deemed sufficient, the current maximum capacities of the planned reservoirs could be larger than they need to be. The method can also be used to inform which of the proposed reservoir type and their storage sizes would allow for the highest downstream benefits to Sudan in different objectives of upstream operating objectives (i.e., operated to maximize either average annual energy or firm energy). The proposed approach identifies the most promising system designs, reveals how they imply different trade-offs between metrics of system performance, and helps system planners asses the sensitivity of overall performance to the design parameters of component reservoirs.
Methane Emissions from United States Natural Gas Gathering and Processing.
Marchese, Anthony J; Vaughn, Timothy L; Zimmerle, Daniel J; Martinez, David M; Williams, Laurie L; Robinson, Allen L; Mitchell, Austin L; Subramanian, R; Tkacik, Daniel S; Roscioli, Joseph R; Herndon, Scott C
2015-09-01
New facility-level methane (CH4) emissions measurements obtained from 114 natural gas gathering facilities and 16 processing plants in 13 U.S. states were combined with facility counts obtained from state and national databases in a Monte Carlo simulation to estimate CH4 emissions from U.S. natural gas gathering and processing operations. Total annual CH4 emissions of 2421 (+245/-237) Gg were estimated for all U.S. gathering and processing operations, which represents a CH4 loss rate of 0.47% (±0.05%) when normalized by 2012 CH4 production. Over 90% of those emissions were attributed to normal operation of gathering facilities (1697 +189/-185 Gg) and processing plants (506 +55/-52 Gg), with the balance attributed to gathering pipelines and processing plant routine maintenance and upsets. The median CH4 emissions estimate for processing plants is a factor of 1.7 lower than the 2012 EPA Greenhouse Gas Inventory (GHGI) estimate, with the difference due largely to fewer reciprocating compressors, and a factor of 3.0 higher than that reported under the EPA Greenhouse Gas Reporting Program. Since gathering operations are currently embedded within the production segment of the EPA GHGI, direct comparison to our results is complicated. However, the study results suggest that CH4 emissions from gathering are substantially higher than the current EPA GHGI estimate and are equivalent to 30% of the total net CH4 emissions in the natural gas systems GHGI. Because CH4 emissions from most gathering facilities are not reported under the current rule and not all source categories are reported for processing plants, the total CH4 emissions from gathering and processing reported under the EPA GHGRP (180 Gg) represents only 14% of that tabulated in the EPA GHGI and 7% of that predicted from this study.
Chapman, D F; Dassanayake, K; Hill, J O; Cullen, B R; Lane, N
2012-07-01
The irrigated dairy industry in southern Australia has experienced significant restrictions in irrigation water allocations since 2005, consistent with climate change impact predictions for the region. Simulation models of pasture growth (DairyMod), crop yield (Agricultural Production Systems Simulator, APSIM), and dairy system management and production (UDDER) were used in combination to investigate a range of forage options that may be capable of sustaining dairy business profitability under restricted water-allocation scenarios in northern Victoria, Australia. A total of 23 scenarios were simulated and compared with a base farm system (100% of historical water allocations, grazed perennial ryegrass pasture with supplements; estimated operating surplus $A2,615/ha at a milk price of $A4.14/kg of milk solids). Nine simulations explored the response of the base farm to changes in stocking rate or the implementation of a double cropping rotation on 30% of farm area, or both. Five simulations explored the extreme scenario of dairying without any irrigation water. Two general responses to water restrictions were investigated in a further 9 simulations. Annual ryegrass grazed pasture, complemented by a double cropping rotation (maize grown in summer for silage, followed by either brassica forage crop and annual ryegrass for silage in winter and spring) on 30% of farm area, led to an estimated operating surplus of $A1746/ha at the same stocking rate as the base farm when calving was moved to autumn (instead of late winter, as in the base system). Estimated total irrigation water use was 2.7ML/ha compared with 5.4ML/ha for the base system. Summer-dormant perennial grass plus double cropping (30% of farm area) lifted operating surplus by a further $A100/ha if associated with autumn calving (estimated total irrigation water use 3.1ML/ha). Large shifts in the forage base of dairy farms could sustain profitability in the face of lower, and fluctuating, water allocations. However, changes in other strategic management policies, notably calving date and stocking rate, would be required, and these systems would be more complex to manage. The adaptation scenarios that resulted in the highest estimated operating surplus were those where at least 10 t of pasture or crop DM was grazed directly by cows per hectare per year, resulting in grazed pasture intake of at least 2 t of DM/cow, and at least 60% of all homegrown feed that was consumed was grazed directly. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
41 CFR 102-192.90 - What must we include in our annual mail management report to GSA?
Code of Federal Regulations, 2011 CFR
2011-01-01
... our annual mail management report to GSA? 102-192.90 Section 102-192.90 Public Contracts and Property... annual mail management report to GSA? Your annual report must— (a) Identify your agency mail manager; in... person serving in this role. (b) State the total amounts paid to each service provider during the...
Optimisation of Noosa BNR plant to improve performance and reduce operating costs.
Thomas, M; Wright, P; Blackall, L; Urbain, V; Keller, J
2003-01-01
Noosa WWTP is publicly owned and privately operated by Australian Water Services. The process includes primary sedimentation, raw sludge fermentation, biological nutrient removal (BNR), sand filtration and ultraviolet (UV) disinfection. An innovative feature of the plant is the supplementary carbon dosing facility to avoid the use of metal salts (alum or ferric) for phosphorus removal. The average flow treated during 2000 was 9.0 ML/d. The annual 50 percentile effluent quality requirements for nutrients are total N < 5 mg/L and total P < 1 mg/L. The objectives of this project were to: determine the cause of variability in phosphorus removal; develop a strategy to control the variability in phosphorus removal; and minimise the operating cost of supplementary carbon dosing while achieving the effluent quality requirements. An investigation of chemical and microbiological parameters was implemented and it was concluded that there were several factors causing variability in phosphorus removal, rather than a single cause. The following four major causes were identified, and the control strategies that were adopted resulted in the plant achieving annual 50 percentile effluent total P = 0.37 mg/L and total N = 3.0 mg/L during 2001. First, phosphorus removal was limited by the available VFA supply due to consumption of VFA by other organisms competing with phosphate accumulating organisms (PAO), and due to diurnal variations in the sewage VFA and phosphate concentrations. Therefore, supplementary carbon dosing was essential to make allowance for competing reactions. Second, increasing the fermenter VFA yield via supplementary carbon dosing with molasses was found to be an effective and economic way of ensuring reliable phosphorus removal. Third, nitrate in the RAS resulted in consumption of VFA by denitrifying bacteria, particularly with process configurations where the RAS was recycled directly into the anaerobic zone. Incorporating a RAS denitrification zone into the process rectified this problem. Finally, glycogen accumulating organisms (GAO) were observed in BNR sludge samples, and consumption of VFA by GAO appeared to cause decreased phosphorus removal. Better phosphorus removal was obtained using VFA derived from the fermenter than dosing an equivalent amount of acetic acid. It was hypothesized that GAO have a competitive advantage to use acetate and PAO have a competitive advantage to use propionate, butyrate or some other soluble COD compound in the fermenter effluent. Contrary to popular belief, acetate may not be the optimum VFA for biological phosphorus removal. The competition between PAO and GAO for different VFA species under anaerobic conditions requires further investigation in order to control the growth of GAO and thereby improve reliability of biological phosphorus removal processes.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-08
... Activities: Company-Run Annual Stress Test Reporting Template and Documentation for Covered Institutions With... titled, ``Company-Run Annual Stress Test Reporting Template and Documentation for Covered Institutions... under News and Issuances ( http://www.occ.treas.gov/tools-forms/forms/bank-operations/stress-test...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-03
... in certain circumstances, e.g., recall of the device, the occurrence of unanticipated adverse effects... Annual Reporting Burden \\1\\ Number of Average Activity/21 CFR Section Number of responses per Total annual burden per Total hours respondents respondent responses response Waivers--812.10 1 1 1 1 1 IDE...
29 CFR 779.253 - What is included in computing the total annual inflow volume.
Code of Federal Regulations, 2010 CFR
2010-07-01
... FAIR LABOR STANDARDS ACT AS APPLIED TO RETAILERS OF GOODS OR SERVICES Employment to Which the Act May... taxes and other charges which the enterprise must pay for such goods. Generally, all charges will be... computing the total annual inflow volume. The goods which the establishment purchases or receives for resale...
Code of Federal Regulations, 2011 CFR
2011-01-01
... Reverse Mortgage Transactions K Appendix K to Part 226 Banks and Banking FEDERAL RESERVE SYSTEM (CONTINUED) BOARD OF GOVERNORS OF THE FEDERAL RESERVE SYSTEM TRUTH IN LENDING (REGULATION Z) Pt. 226, App. K Appendix K to Part 226—Total Annual Loan Cost Rate Computations for Reverse Mortgage Transactions (a...
Code of Federal Regulations, 2012 CFR
2012-01-01
... Reverse Mortgage Transactions K Appendix K to Part 226 Banks and Banking FEDERAL RESERVE SYSTEM (CONTINUED) BOARD OF GOVERNORS OF THE FEDERAL RESERVE SYSTEM TRUTH IN LENDING (REGULATION Z) Pt. 226, App. K Appendix K to Part 226—Total Annual Loan Cost Rate Computations for Reverse Mortgage Transactions (a...
Code of Federal Regulations, 2010 CFR
2010-01-01
... Reverse Mortgage Transactions K Appendix K to Part 226 Banks and Banking FEDERAL RESERVE SYSTEM (CONTINUED) BOARD OF GOVERNORS OF THE FEDERAL RESERVE SYSTEM TRUTH IN LENDING (REGULATION Z) Pt. 226, App. K Appendix K to Part 226—Total Annual Loan Cost Rate Computations for Reverse Mortgage Transactions (a...
Dacia M Meneguzzo; Susan J. Crocker; Mark D. Nelson; Charles J. Barnett; Brett J. Butler; Grant M. Domke; Mark H. Hansen; Mark A. Hatfield; Greg C. Liknes; Andrew J. Lister; Tonya W. Lister; Ronald J. Piva; Barry T. (Ty) Wilson; Christopher W. Woodall
2012-01-01
The second full annual inventory of Nebraska's forests reports more than 1.5 million acres of forest land and 39 tree species. Forest land is dominated by the elm/ash/cottonwood and oak/hickory forest types, which occupy nearly half of the total forest land area. The volume of growing stock on timberland currently totals 1.1 billion cubic feet. The average annual...
Nutrient loading to Lewisville Lake, north-central Texas, 1984-87
Gain, W.S.; Baldys, Stanley
1995-01-01
The estimated long-term (1974-89 water years) average annual total nitrogen load (excluding loads from sewage-treatment plants in ungaged areas) is 11,800 pounds per day. The estimated long-term (1974 89 water years) average annual total phosphorus load (excluding loads from sewage-treatment plants in ungaged areas) is 1,100 pounds per day.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-15
... amended. Total Annual Burden: 1,000 hours. Total Annual Cost: $180,000. Privacy Impact Assessment: N/A... market must: Indicate on the long-form application (FCC Form 601) that it intends to serve a qualifying tribal land within that market; Within 180 days after the filing deadline for the long- form application...
Weight distribution in the current annual twigs of barclay willow.
John F. Thilenius
1988-01-01
The current annual twigs of unbrowsed Barclay willow (Salix barclayi Anderss.) grow as gently tapering cylinders. Consequently, the distal half of the twig has only 33 to 41 percent of the total weight. Longer twigs have proportionally less weight in the distal end. The total weight of an unbrowsed twig can be estimated by simple regression of...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-24
... 1934, as amended. Total Annual Burden: 12,146 hours. Total Annual Cost: 24,000. Privacy Act Impact... required to carry the signal originating as analog after commencing carriage of digital signals on June 8... signals that originate as analog signals for carriage commencing on December 8, 2005 and ending on...
NASA Technical Reports Server (NTRS)
Hilsenrath, E.; Heath, D. F.; Schlesinger, B. M.
1978-01-01
The first two years of Backscattered Ultraviolet (BUV) ozone data from the Nimbus-4 spacecraft were reprocessed. The seasonal variations of total ozone for the period April 1970 to April 1972 are described using daily zonal means to 10 deg latitude zones and a time-latitude cross section. In addition, the BUV data are compared with analyzed Dobson data and with IRIS data also obtained from the Nimbus-4 spacecraft. A harmonic analysis was performed on the daily zonal means. Amplitudes, days of peaks, and percentage of variance were computed for annual and semi-annual waves and for higher harmonics of an annual period for the two years. Asymmetries are found in the annual waves in the two hemispheres, with a subtle interannual difference which may be due to changes in the general circulation. A significant semi-annual component is detected in the tropics for the first year, which appears to result from influences of the annual waves in the two hemispheres.
Graham, Jennifer L.; Stone, Mandy L.; Rasmussen, Teresa J.; Poulton, Barry C.
2010-01-01
The Johnson County Blue River Main Wastewater Treatment Facility discharges into the upper Blue River near the border between Johnson County, Kansas and Jackson County, Missouri. During 2005 through 2007 the wastewater treatment facility underwent upgrades to increase capacity and include biological nutrient removal. The effects of wastewater effluent on environmental and biological conditions of the upper Blue River were assessed by comparing an upstream site to two sites located downstream from the wastewater treatment facility. Environmental conditions were evaluated using previously and newly collected discrete and continuous data, and were compared with an assessment of biological community composition and ecosystem function along the upstream-downstream gradient. This evaluation is useful for understanding the potential effects of wastewater effluent on water quality, biological community structure, and ecosystem function. In addition, this information can be used to help achieve National Pollution Discharge Elimination System (NPDES) wastewater effluent permit requirements after additional studies are conducted. The effects of wastewater effluent on the water-quality conditions of the upper Blue River were most evident during below-normal and normal streamflows (about 75 percent of the time), when wastewater effluent contributed more than 20 percent to total streamflow. The largest difference in water-quality conditions between the upstream and downstream sites was in nutrient concentrations. Total and inorganic nutrient concentrations at the downstream sites during below-normal and normal streamflows were 4 to 15 times larger than at the upstream site, even after upgrades to the wastewater treatment facility were completed. However, total nitrogen concentrations decreased in wastewater effluent and at the downstream site following wastewater treatment facility upgrades. Similar decreases in total phosphorus were not observed, likely because the biological phosphorus removal process was not optimized until after the study was completed. Total nitrogen and phosphorus from the wastewater treatment facility contributed a relatively small percentage (14 to 15 percent) to the annual nutrient load in the upper Blue River, but contributed substantially (as much as 75 percent) to monthly loads during seasonal low-flows in winter and summer. During 2007 and 2008, annual discharge from the wastewater treatment facility was about one-half maximum capacity, and estimated potential maximum annual loads were 1.6 to 2.4 times greater than annual loads before capacity upgrades. Even when target nutrient concentrations are met, annual nutrient loads will increase when the wastewater treatment facility is operated at full capacity. Regardless of changes in annual nutrient loads, the reduction of nutrient concentrations in the Blue River Main wastewater effluent will help prevent further degradation of the upper Blue River. The Blue River Main Wastewater Treatment Facility wastewater effluent caused changes in concentrations of several water-quality constituents that may affect biological community structure and function including larger concentrations of bioavailable nutrients (nitrate and orthophosphorus) and smaller turbidities. Streambed-sediment conditions were similar along the upstream-downstream gradient and measured constituents did not exceed probable effect concentrations. Habitat conditions declined along the upstream-downstream gradient, largely because of decreased canopy cover and riparian buffer width and increased riffle-substrate fouling. Algal biomass, primary production, and the abundance of nutrient-tolerant diatoms substantially increased downstream from the wastewater treatment facility. Likewise, the abundance of intolerant macroinvertebrate taxa and Kansas Department of Health and Environment aquatic-life-support scores, derived from macroinvertebrate data, significantly decreased downstream from the wastewater
14 CFR 91.875 - Annual progress reports.
Code of Federal Regulations, 2013 CFR
2013-01-01
...) AIR TRAFFIC AND GENERAL OPERATING RULES GENERAL OPERATING AND FLIGHT RULES Operating Noise Limits § 91... report, that specific planning data be considered proprietary. (e) If an operator's actions during any...
14 CFR 91.875 - Annual progress reports.
Code of Federal Regulations, 2011 CFR
2011-01-01
...) AIR TRAFFIC AND GENERAL OPERATING RULES GENERAL OPERATING AND FLIGHT RULES Operating Noise Limits § 91... report, that specific planning data be considered proprietary. (e) If an operator's actions during any...
14 CFR 91.875 - Annual progress reports.
Code of Federal Regulations, 2010 CFR
2010-01-01
...) AIR TRAFFIC AND GENERAL OPERATING RULES GENERAL OPERATING AND FLIGHT RULES Operating Noise Limits § 91... report, that specific planning data be considered proprietary. (e) If an operator's actions during any...
14 CFR 91.875 - Annual progress reports.
Code of Federal Regulations, 2012 CFR
2012-01-01
...) AIR TRAFFIC AND GENERAL OPERATING RULES GENERAL OPERATING AND FLIGHT RULES Operating Noise Limits § 91... report, that specific planning data be considered proprietary. (e) If an operator's actions during any...
14 CFR 91.875 - Annual progress reports.
Code of Federal Regulations, 2014 CFR
2014-01-01
...) AIR TRAFFIC AND GENERAL OPERATING RULES GENERAL OPERATING AND FLIGHT RULES Operating Noise Limits § 91... report, that specific planning data be considered proprietary. (e) If an operator's actions during any...
Shaping America's Transportation Future: Annual Project Accomplishments.
DOT National Transportation Integrated Search
2016-01-01
Volpes mission is to improve the transportation system by anticipating emerging issues and advancing technical, operational, and institutional innovations. Shaping Americas Transportation Future: Annual Project Accomplishments highlights Volpe...
Journey, Celeste A.; Caldwell, Andral W.; Feaster, Toby D.; Petkewich, Mattew D.; Bradley, Paul M.
2011-01-01
The U.S. Geological Survey, in cooperation with Spartanburg Water, evaluated the concentrations, loads, and yields of suspended sediment, dissolved ammonia, dissolved nitrate plus nitrite, total organic nitrogen, total nitrogen, dissolved orthophosphate, dissolved phosphorus, and total phosphorus at sites in the South Pacolet, North Pacolet, and Pacolet Rivers in northern South Carolina and southwestern North Carolina from October 1, 2005, to September 30, 2009 (water years 2006 to 2009). Nutrient and sediment loads and yields also were computed for the intervening subbasin of the Pacolet River not represented by the South and North Pacolet River Basins. Except for a few outliers, the majority of the measurements of total nitrogen concentrations were well below the U.S. Environmental Protection Agency recommended guideline of 0.69 milligram per liter for streams and rivers in the nutrient ecoregion IX, which includes the study area within the Pacolet River Basin. Dissolved orthophosphate, dissolved phosphorus, and total phosphorus concentrations were significantly lower at the South Pacolet River site compared to the North Pacolet and Pacolet River sites. About 90 percent of the total phosphorus concentrations at the South Pacolet River site were below the U.S. Environmental Protection Agency recommended guideline of 0.37 milligram per liter, and more than 75 percent of the total phosphorus concentrations at the North Pacolet and Pacolet River sites were above that guideline. At all sites, minimum annual nutrient loads for the estimation period were observed during water year 2008 when severe drought conditions were present. An estimated mean annual total nitrogen load of 37,770 kilograms per year and yield of 2.63 kilograms per hectare per year were determined for the South Pacolet River site for the estimation period. The North Pacolet River site had a mean annual total nitrogen load of 65,890 kilograms per year and yield of 2.19 kilograms per hectare per year. The Pacolet River had a mean annual total nitrogen load of 99,780 kilograms per year and yield of 1.82 kilograms per hectare per year. Mean annual total phosphorus loads of 2,576; 9,404; and 11,710 kilograms per year and yields of 0.180, 0.313, and 0.213 kilograms per hectare per year were estimated at the South Pacolet, North Pacolet, and Pacolet River sites, respectively. Annually, the intervening subbasin of the Pacolet River contributed negligible amounts of total nitrogen and total phosphorus loads, and large losses of dissolved nitrate plus nitrite and orthophosphate loads were determined for the subbasin. Biological (algal) uptake in the two reservoirs in this intervening area was considered the likely explanation for the loss of these constituents. Estimated mean annual suspended-sediment loads were 21,190,000; 9,895,000; and 6,547,000 kilograms per year at the South Pacolet, North Pacolet, and Pacolet River sites, respectively. In the intervening Pacolet River subbasin, computed annual suspended-sediment loads were consistently negative, indicating large percentage losses in annual suspended-sediment load. Sedimentation processes in the two reservoirs are the most likely explanations for these apparent losses. At all sites, the winter season tended to have the highest estimated seasonal dissolved orthophosphate and dissolved nitrate plus nitrite fluxes, and the summer and fall seasons tended to have the lowest fluxes. The reverse pattern, however, was observed in the intervening drainage area in the Pacolet River where the lowest fluxes of dissolved orthophosphate and nitrate plus nitrite occurred during the winter and spring seasons and the highest occurred during the summer and fall seasons. Synoptic samples were collected during a high-flow event in August 2009 at eight sites that represented shoreline and minor tributary drainages. The South Pacolet River site was identified as contributing greater than 80 percent of the cumulative nutrient and sediment l
Francis, David O.; Pearce, Elizabeth C.; Ni, Shenghua; Garrett, C. Gaelyn; Penson, David F.
2014-01-01
Objectives Population-level incidence of vocal fold paralysis after thyroidectomy for well-differentiated thyroid carcinoma (WDTC) is not known. This study aimed to measure longitudinal incidence of post-operative vocal fold paralyses and need for directed interventions in the Medicare population undergoing total thyroidectomy for WDTC. Study Design Retrospective Cohort Study Setting United States Population Subjects Medicare Beneficiaries Methods SEER-Medicare data (1991 – 2009) were used to identify beneficiaries who underwent total thyroidectomy for WDTC. Incident vocal fold paralyses and directed interventions were identified. Multivariate analyses were used to determine factors associated with odds of developing these surgical complications. Results Of 5,670 total thyroidectomies for WDTC, 9.5% were complicated by vocal fold paralysis [8.2% unilateral vocal fold paralysis (UVFP); 1.3% bilateral vocal fold paralysis (BVFP)]. Rate of paralyses decreased 5% annually from 1991 to 2009 (OR 0.95, 95% CI 0.93 – 0.97; p<0.001). Overall, 22% of patients with vocal fold paralysis required surgical intervention (UVFP 21%, BVFP 28%). Multivariate logistic regression revealed odds of post-thyroidectomy paralysis increased with each additional year of age, with non-Caucasian race, particular histologic types, advanced stage, and in particular registry regions. Conclusions Annual rates of post-thyroidectomy vocal fold paralyses are decreasing among Medicare beneficiaries with WDTC. High incidence in this aged population is likely due to a preponderance of temporary paralyses, which is supported by the need for directed intervention in less than a quarter of affected patients. Further population-based studies are needed to refine the population incidence and risk factors for paralyses in the aging population. PMID:24482349
Groundwater balance in the Khor Arbaat basin, Red Sea State, eastern Sudan
NASA Astrophysics Data System (ADS)
Elsheikh, Abdalla E. M.; Zeielabdein, Khalid A. Elsayed; Babikir, Ibrahim A. A.
2009-12-01
The Khor Arbaat basin is the main source of potable water supply for the more than 750,000 inhabitants of Port Sudan, eastern Sudan. The variation in hydraulic conductivity and storage capacity is due to the heterogeneity of the sediments, which range from clay and silt to gravely sand and boulders. The water table rises during the summer and winter rainy seasons; it reaches its lowest level in the dry season. The storage capacity of the Khor Arbaat aquifer is estimated to be 21.75 × 106 m3. The annual recharge through the infiltration of flood water is about 1.93 × 106 m3. The groundwater recharge, calculated as underground inflow at the ‘upper gate’, is 1.33 × 105 m3/year. The total annual groundwater recharge is 2.06 × 106 m3. The annual discharge through underground outflow at the ‘lower gate’ (through which groundwater flows onto the coastal plain) is 3.29 × 105 m3/year. Groundwater discharge due to pumping from Khor Arbaat basin is 4.38 × 106 m3/year on average. The total annual groundwater discharge is about 4.7 × 106 m3. A deficit of 2.6 × 106 m3/year is calculated. Although the total annual discharge is twice the estimated annual recharge, additional groundwater flow from the fractured basement probably balances the annual groundwater budget since no decline is observed in the piezometric levels.
Agents and trends in health care workers' occupational asthma
Walters, G. I.; Moore, V. C.; McGrath, E. E.; Burge, P. S.; Henneberger, P. K.
2015-01-01
Background There is a disproportionately high number of cases of work-related asthma occurring in health care occupations due to agents such as glutaraldehyde, latex and cleaning products. Aims To understand the causes and measure trends over time of occupational asthma (OA) in health care workers (HCWs). Methods We reviewed OA notifications from the Midland Thoracic Society's Surveillance Scheme of Occupational Asthma (SHIELD) database in the West Midlands, UK, from 1991 to 2011 and gathered data on occupation, causative agent and annual number of notifications. Results There were 182 cases of OA in HCWs (median annual notifications = 7; interquartile range [IQR] = 5–11), representing 5–19% of annual SHIELD notifications. The modal annual notification was 20 (in 1996); notifications have declined since then, in line with total SHIELD notifications. The majority of cases (136; 75%) occurred in nursing, operating theatre, endoscopy and radiology staff. The most frequently implicated agents were glutaraldehyde (n = 69), latex (n = 47) and cleaning products (n = 27), accounting for 79% of the 182 cases. Cleaning product-related OA was an emerging cause with 22 cases after 2001 and only 5 cases between 1991 and 2000. Conclusions Control measures within the UK National Health Service have seen a decline in OA in HCWs due to latex and glutaraldehyde, though OA remains a problem amongst HCWs exposed to cleaning products. Continuing efforts are required to limit the number of cases in this employment sector. PMID:23933593
Development of a Residential Ground-Source Integrated Heat Pump
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rice, C Keith; Baxter, Van D; Hern, Shawn
2013-01-01
A residential-size ground-source integrated heat pump (GSIHP) system has been developed and is currently being field tested. The system is a nominal 2-ton (7 kW) cooling capacity, variable-speed unit, which is multi-functional, e.g. space cooling, space heating, dedicated water heating, and simultaneous space cooling and water heating. High-efficiency brushless permanent-magnet (BPM) motors are used for the compressor, indoor blower, and pumps to obtain the highest component performance and system control flexibility. Laboratory test data were used to calibrate a vapor-compression simulation model (HPDM) for each of the four primary modes of operation. The model was used to optimize the internalmore » control options and to simulate the selected internal control strategies, such as controlling to a constant air supply temperature in the space heating mode and a fixed water temperature rise in water heating modes. Equipment performance maps were generated for each operation mode as functions of all independent variables for use in TRNSYS annual energy simulations. These were performed for the GSIHP installed in a well-insulated 2600 ft2(242 m2) house and connected to a vertical ground loop heat exchanger(GLHE). We selected a 13 SEER (3.8 CSPF )/7.7 HSPF (2.3 HSPF, W/W) ASHP unit with 0.90 Energy Factor (EF) resistance water heater as the baseline for energy savings comparisons. The annual energy simulations were conducted over five US climate zones. In addition, appropriate ground loop sizes were determined for each location to meet 10-year minimum and maximum design entering water temperatures (EWTs) to the equipment. The prototype GSIHP system was predicted to use 52 to 59% less energy than the baseline system while meeting total annual space conditioning and water heating loads.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-14
... collection titled, ``Annual Stress Test Reporting Template and Documentation for Covered Banks with [email protected] . Include ``Annual Stress Test Reporting Template and Documentation for Covered Banks with...: Annual Stress Test Reporting Template and Documentation for Covered Banks With Total Consolidated Assets...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-24
... information collection titled, ``Annual Stress Test Reporting Template and Documentation for Covered Banks.... Email: [email protected] . Include ``Annual Stress Test Reporting Template and Documentation'' on the... information collection: Annual Stress Test Reporting Template and Documentation for Covered Banks With Total...
Annual and Seasonal Global Variation in Total Ozone and Layer-Mean Ozone, 1958-1987 (1991)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Angell, J. K.; Korshover, J.; Planet, W. G.
For 1958 through 1987, this data base presents total ozone variations and layer mean ozone variations expressed as percent deviations from the 1958 to 1977 mean. The total ozone variations were derived from mean monthly ozone values published in Ozone Data for the World by the Atmospheric Environment Service in cooperation with the World Meteorological Organization. The layer mean ozone variations are derived from ozonesonde and Umkehr observations. The data records include year, seasonal and annual total ozone variations, and seasonal and annual layer mean ozone variations. The total ozone data are for four regions (Soviet Union, Europe, North America,more » and Asia); five climatic zones (north and south polar, north and south temperate, and tropical); both hemispheres; and the world. Layer mean ozone data are for four climatic zones (north and south temperate and north and south polar) and for the stratosphere, troposphere, and tropopause layers. The data are in two files [seasonal and year-average total ozone (13.4 kB) and layer mean ozone variations (24.2 kB)].« less
Health plan utilization and costs of specialty drugs within 4 chronic conditions.
Gleason, Patrick P; Alexander, G Caleb; Starner, Catherine I; Ritter, Stephen T; Van Houten, Holly K; Gunderson, Brent W; Shah, Nilay D
2013-09-01
Drugs are most typically defined as specialty because they are expensive; however, other criteria used to define a drug as specialty include biologic drugs, the need to inject or infuse the drug, the requirement for special handling, or drug availability only via a limited distribution network. Specialty drugs play an increasingly important role in the treatment of chronic conditions such as multiple sclerosis (MS), rheumatoid arthritis (RA), psoriasis, and inflammatory bowel disease (IBD), yet little is known regarding the comprehensive medical and pharmacy benefit utilization and cost trends for these conditions. To describe MS, RA, psoriasis, and IBD trends for condition prevalence, treatment with specialty drugs, specialty costs, nonspecialty costs, and total direct costs of care within the medical and pharmacy benefits. This was a descriptive analysis of a commercially insured population made up of 1 million members, using integrated medical and pharmacy administrative claims data from 2008 to 2010. Analyses were limited to continuously enrolled commercially insured individuals less than 65 years of age. Condition-specific cohorts for MS, RA, psoriasis, and IBD were defined using standardized criteria. Trends in condition prevalence, specialty drug use for the conditions, and direct total cost of care were analyzed. The direct costs were subcategorized into the following: medical benefit specialty drug costs, medical benefit all other costs, pharmacy benefit specialty drug costs, and pharmacy benefit all other costs. Trends and compound annual growth rates were calculated for the total cost of care and subcategory costs from 2008 through 2010. Condition prevalence ranged from a low of 1,720 per million members for MS to a high of 4,489 per million members for RA. Psoriasis and MS condition prevalence rates were unchanged over the 3 years; however, IBD prevalence increased 7.0%, and RA prevalence increased 9.7%. The rate of specialty drug use was lowest for IBD (13.7%) and highest for MS (71.8%). The lowest total annual cost of care was for psoriasis ($14,815), and the highest total annual cost was for MS ($36,901). The most commonly used specialty drugs for each of the conditions were as follows: glatiramer (MS), etanercept (RA and psoriasis), and infliximab (IBD). The total annual costs were more than double for the specialty drug users for psoriasis compared with all the psoriasis members ($29,565 vs. $14,815). The total costs were only somewhat higher among MS members using specialty drugs ($41,760 vs. $36,901). Among specialty drug users for each of the cohorts, the annual costs of specialty drugs accounted for 50% or more of the total annual costs. The annual spending growth rate for specialty drugs ranged from 4.4% to 18.0%. Although specialty drug utilization varied widely across the 4 chronic conditions analyzed, when specialty drugs were used they accounted for the majority of the annual total direct cost of care. Because specialty drugs are accounting for a growing portion of chronic disease total cost of care, health insurers will need to become more vigilant regarding specialty drug use and focus on 4 cost saving management opportunities: drug distribution channel, utilization management, contracting activities, and care coordination.
Tier One Performance Screen Initial Operational Test and Evaluation: 2011 Annual Report
2013-01-01
OPERATIONAL TEST AND EVALUATION: 2011 ANNUAL REPORT EXECUTIVE SUMMARY Research Requirement: In addition to educational, physical , and...34 Table 5.4. Incremental Validity Estimates for the TAPAS and TOPS Composite Scales over the AFQT for Predicting IMT Physical Fitness Criteria by...Validity Estimates for the TAPAS and TOPS Composite Scales over the AFQT for Predicting In-Unit Physical Fitness Criteria by Education Tier
Code of Federal Regulations, 2014 CFR
2014-10-01
... 50 Wildlife and Fisheries 13 2014-10-01 2014-10-01 false Required Buying and Production Forms for use With State of Alaska Commercial Operator's Annual Report (COAR) 18 Table 18 to Part 679 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE (CONTINUED) FISHERIES OF...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 50 Wildlife and Fisheries 13 2014-10-01 2014-10-01 false Process Codes for Use With State of Alaska Commercial Operator's Annual Report (COAR) 17 Table 17 to Part 679 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE (CONTINUED) FISHERIES OF THE EXCLUSIVE ECONOMIC...
Code of Federal Regulations, 2010 CFR
2010-10-01
... Operator's Annual Report (COAR) Fishery Form Number and Name Salmon Salmon Buying (A)(1) Seine gear (A)(1) Gillnet gear (A)(2) Troll gear (A)(2) Hatchery (A)(3) Miscellaneous gear King Salmon Production (B)(1) Production (B)(1) Canned Production Sockeye Salmon Production: (B)(2)(i) Production (B)(2)(ii) Canned...
ERIC Educational Resources Information Center
Rehabilitation Services Administration (ED), Washington, DC.
The fiscal year 1981 annual report of the Rehabilitation Services Administration's activities under the Rehabilitation Act of 1973, as amended, is presented; program operations, program development activities, functions of the National Institute of Handicapped Research, and other provisions of the Act, are described. Program operations include:…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schneider, Abraham; Schneider, Gia; McKinstry, Katherine
Natel Energy is a low-head, distributed hydropower company based out of Alameda, CA. Natel manufactures and sells proprietary hydroelectric turbines called hydroEngines® that are suitable for low-head, high-flow settings, and range from 30kW to 1 MW of capacity per unit. Natel’s hydroEngine is a state-ofthe-art two stage impulse turbine, using blades mounted symmetrically on two belts perpendicular to the axis of travel, and using linearly-moving foils, rather than a rotor, to enable efficient conversion of kinetic energy of large volumes of water at low head with no risk of cavitation. In addition, the hydroEngine can be installed at or abovemore » tailwater level, reducing the excavation necessary to build the powerhouse and thus reducing total installed cost and project footprint. Thus, the hydroEngine technology enables a new generation of small hydro installations with low cost of project development, fish-friendly operations, and small project footprint. In September of 2015, Natel Energy formally commissioned its first project installation in Madras, Oregon, installing 1 SLH100 turbine at an existing drop structure on the North Unit Irrigation District (NUID) Main Canal. The water falls between 13.5 feet to 16.5 feet at this structure, depending on flow. The plant has an installed capacity of 250 kW and an expected annual generation of approximately 873 MWh. The plant operates at an annual capacity factor of 40%, and a capacity factor over the irrigation season, or period of available flow, of 80%. Annual capacity factor is calculated as a percentage of plant operating hours relative to a total of 8,760 hours in a year; because the irrigation canal in which the Project is located only runs water from April to October, the available flow capacity factor is higher. Net greenhouse gas reductions from the Monroe Project are estimated to be 602 tCO2/year. The purpose of this report is to provide an overview of the specifications for Natel’s first commissioned project, the project development process, the plant’s performance, project costs, and the construction, installation, and commissioning process. We hope that this report will provide useful context for assessment of the hydroEngine as a viable technology choice for future distributed, low-head hydropower projects, as well as assessment of the bankability, performance, reliability, and cost of the hydroEngine.« less
Estimating Evapotranspiration Using an Observation Based Terrestrial Water Budget
NASA Technical Reports Server (NTRS)
Rodell, Matthew; McWilliams, Eric B.; Famiglietti, James S.; Beaudoing, Hiroko K.; Nigro, Joseph
2011-01-01
Evapotranspiration (ET) is difficult to measure at the scales of climate models and climate variability. While satellite retrieval algorithms do exist, their accuracy is limited by the sparseness of in situ observations available for calibration and validation, which themselves may be unrepresentative of 500m and larger scale satellite footprints and grid pixels. Here, we use a combination of satellite and ground-based observations to close the water budgets of seven continental scale river basins (Mackenzie, Fraser, Nelson, Mississippi, Tocantins, Danube, and Ubangi), estimating mean ET as a residual. For any river basin, ET must equal total precipitation minus net runoff minus the change in total terrestrial water storage (TWS), in order for mass to be conserved. We make use of precipitation from two global observation-based products, archived runoff data, and TWS changes from the Gravity Recovery and Climate Experiment satellite mission. We demonstrate that while uncertainty in the water budget-based estimates of monthly ET is often too large for those estimates to be useful, the uncertainty in the mean annual cycle is small enough that it is practical for evaluating other ET products. Here, we evaluate five land surface model simulations, two operational atmospheric analyses, and a recent global reanalysis product based on our results. An important outcome is that the water budget-based ET time series in two tropical river basins, one in Brazil and the other in central Africa, exhibit a weak annual cycle, which may help to resolve debate about the strength of the annual cycle of ET in such regions and how ET is constrained throughout the year. The methods described will be useful for water and energy budget studies, weather and climate model assessments, and satellite-based ET retrieval optimization.
Arp, Christopher D; Cooper, David J
2004-03-01
We quantified annual sediment deposition, bank erosion, and sediment budgets in nine riverine wetlands that represented a watershed continuum for 1 year in the unregulated Yampa River drainage basin in Colorado. One site was studied for 2 years to compare responses to peak flow variability. Annual mean sediment deposition ranged from 0.01 kg/m(2) along a first-order subalpine stream to 21.8 kg/m(2) at a sixth-order alluvial forest. Annual mean riverbank erosion ranged from 3 kg/m-of-bank at the first-order site to 1000 kg/m at the 6(th)-order site. Total sediment budgets were nearly balanced at six sites, while net export from bank erosion occurred at three sites. Both total sediment deposition (R(2) = 0.86, p < 0.01) and bank erosion (R(2) = 0.77, p < 0.01) were strongly related to bankfull height, and channel sinuosity and valley confinement helped to explain additional variability among sites. The texture and organic fraction of eroded and deposited sediment were relatively similar in most sites and varied among sites by watershed position. Our results indicate that bank erosion generally balances sediment deposition in riverine wetlands, and we found no distinct zones of sediment retention versus export on a watershed continuum. Zones of apparent disequilibrium can occur in unregulated rivers due to factors such as incised channels, beaver activity, and cattle grazing. A primary function of many western riverine wetlands is sediment exchange, not retention, which may operate by transforming materials and compounds in temporary sediment pools on floodplains. These results are considered in the context of the Hydrogeomorphic approach being implemented by the U.S. government for wetland resource management.
Calcante, Aldo; Tangorra, Francesco M; Oberti, Roberto
2016-05-01
Automatic milking systems (AMS) have been a revolutionary innovation in dairy cow farming. Currently, more than 10,000 dairy cow farms worldwide use AMS to milk their cows. Electric consumption is one of the most relevant and uncontrollable operational cost of AMS, ranging between 35 and 40% of their total annual operational costs. The aim of the present study was to measure and analyze the electric energy consumption of 4 AMS with different configurations: single box, central unit featuring a central vacuum system for 1 cow unit and for 2 cow units. The electrical consumption (daily consumption, daily consumption per cow milked, consumption per milking, and consumption per 100L of milk) of each AMS (milking unit + air compressor) was measured using 2 energy analyzers. The measurement period lasted 24h with a sampling frequency of 0.2Hz. The daily total energy consumption (milking unit + air compressor) ranged between 45.4 and 81.3 kWh; the consumption per cow milked ranged between 0.59 and 0.99 kWh; the consumption per milking ranged between 0.21 and 0.33 kWh; and the consumption per 100L of milk ranged between 1.80 to 2.44 kWh according to the different configurations and operational contexts considered. Results showed that AMS electric consumption was mainly conditioned by farm management rather than machine characteristics/architectures. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-28
... enhance the quality, utility, and clarity of the information collected; (d) ways to minimize the burden of... PRA comments to Nicholas A. Fraser, Office of Management and Budget, via fax at 202-395-5167 or via...). Total Annual Burden: 36 hours. Total Annual Cost: N/A. Privacy Act Impact Assessment: N/A. Nature and...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-23
... enhance the quality, utility, and clarity of the information collected; (d) ways to minimize the burden of... PRA comments to Nicholas A. Fraser, Office of Management and Budget, via fax at 202-395-5167 or via e... of 1934, as amended. Total Annual Burden: 17 hours. Total Annual Cost: 63,750. Privacy Act Impact...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-14
..., including the use of automated collection techniques or other forms of information technology, and (e) ways... (ARRA), Pub. L. No. 111-5, 123 Stat 115 (2009). Total Annual Burden: 1,100 hours. Total Annual Cost: N/A... using the Spectrum Database and what improvements or enhancements they would like to see in future...
49 CFR Schedule E to Subpart B of... - Statement of Changes in Financial Position
Code of Federal Regulations, 2010 CFR
2010-10-01
... (specify): 23 24 25 26 27 28Total working capital from extraordinary items and accounting changes 29Total... annual report sources in this column refer to the 1976 Annual Report Form MP-1. For years prior or subsequent to 1976, use comparable sources. Column (c). If the fare/charge increase is filed during the first...
A stream-gaging network analysis for the 7-day, 10-year annual low flow in New Hampshire streams
Flynn, Robert H.
2003-01-01
The 7-day, 10-year (7Q10) low-flow-frequency statistic is a widely used measure of surface-water availability in New Hampshire. Regression equations and basin-characteristic digital data sets were developed to help water-resource managers determine surface-water resources during periods of low flow in New Hampshire streams. These regression equations and data sets were developed to estimate streamflow statistics for the annual and seasonal low-flow-frequency, and period-of-record and seasonal period-of-record flow durations. generalized-least-squares (GLS) regression methods were used to develop the annual 7Q10 low-flow-frequency regression equation from 60 continuous-record stream-gaging stations in New Hampshire and in neighboring States. In the regression equation, the dependent variables were the annual 7Q10 flows at the 60 stream-gaging stations. The independent (or predictor) variables were objectively selected characteristics of the drainage basins that contribute flow to those stations. In contrast to ordinary-least-squares (OLS) regression analysis, GLS-developed estimating equations account for differences in length of record and spatial correlations among the flow-frequency statistics at the various stations.A total of 93 measurable drainage-basin characteristics were candidate independent variables. On the basis of several statistical parameters that were used to evaluate which combination of basin characteristics contribute the most to the predictive power of the equations, three drainage-basin characteristics were determined to be statistically significant predictors of the annual 7Q10: (1) total drainage area, (2) mean summer stream-gaging station precipitation from 1961 to 90, and (3) average mean annual basinwide temperature from 1961 to 1990.To evaluate the effectiveness of the stream-gaging network in providing regional streamflow data for the annual 7Q10, the computer program GLSNET (generalized-least-squares NETwork) was used to analyze the network by application of GLS regression between streamflow and the climatic and basin characteristics of the drainage basin upstream from each stream-gaging station. Improvement to the predictive ability of the regression equations developed for the network analyses is measured by the reduction in the average sampling-error variance, and can be achieved by collecting additional streamflow data at existing stations. The predictive ability of the regression equations is enhanced even further with the addition of new stations to the network. Continued data collection at unregulated stream-gaging stations with less than 14 years of record resulted in the greatest cost-weighted reduction to the average sampling-error variance of the annual 7Q10 regional regression equation. The addition of new stations in basins with underrepresented values for the independent variables of the total drainage area, average mean annual basinwide temperature, or mean summer stream-gaging station precipitation in the annual 7Q10 regression equation yielded a much greater cost-weighted reduction to the average sampling-error variance than when more data were collected at existing unregulated stations. To maximize the regional information obtained from the stream-gaging network for the annual 7Q10, ranking of the streamflow data can be used to determine whether an active station should be continued or if a new or discontinued station should be activated for streamflow data collection. Thus, this network analysis can help determine the costs and benefits of continuing the operation of a particular station or activating a new station at another location to predict the 7Q10 at ungaged stream reaches. The decision to discontinue an existing station or activate a new station, however, must also consider its contribution to other water-resource analyses such as flood management, water quality, or trends in land use or climatic change.
ANNUAL WATER BUDGETS FOR A FORESTED SINKHOLE WETLAND
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hill, Dr. Andrew Jason; Neary, Vincent S
2012-01-01
Annual water budgets spanning two years, 2004 and 2005, are constructed for a sinkhole wetland in the Tennessee Highland Rim following conversion of 13 % of its watershed to impervious surfaces. The effect of watershed development on the hydrology of the study wetland was significant. Surface runoff was the dominant input, with a contribution of 61.4 % of the total. An average of 18.9 % of gross precipitation was intercepted by the canopy and evaporated. Seepage from the surface water body to the local groundwater system accounted for 83.1 % of the total outflow. Deep recharge varied from 43.2 %more » (2004) to 12.1 % (2005) of total outflow. Overall, evapotranspiration accounted for 72.4 % of the total losses, with an average of 65.7 % lost from soil profile storage. The annual water budgets indicate that deep recharge is a significant hydrologic function performed by isolated sinkhole wetlands, or karst pans, on the Tennessee Highland Rim. Continued hydrologic monitoring of sinkhole wetlands are needed to evaluate hydrologic function and response to anthropogenic impacts. The regression technique developed to estimate surface runoff entering the wetland is shown to provide reasonable annual runoff estimates, but further testing is needed.« less
40 CFR 97.534 - Recordkeeping and reporting.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Acid Rain Program or a TR NOX Annual emissions limitation or if the owner or operator of such unit... not subject to the Acid Rain Program or a TR NOX Annual emissions limitation, then the designated... Ozone Season units that are also subject to the Acid Rain Program, TR NOX Annual Trading Program, TR SO2...
40 CFR 97.534 - Recordkeeping and reporting.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Acid Rain Program or a TR NOX Annual emissions limitation or if the owner or operator of such unit... not subject to the Acid Rain Program or a TR NOX Annual emissions limitation, then the designated... Ozone Season units that are also subject to the Acid Rain Program, TR NOX Annual Trading Program, TR SO2...
40 CFR 97.534 - Recordkeeping and reporting.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Acid Rain Program or a TR NOX Annual emissions limitation or if the owner or operator of such unit... not subject to the Acid Rain Program or a TR NOX Annual emissions limitation, then the designated... Ozone Season units that are also subject to the Acid Rain Program, TR NOX Annual Trading Program, TR SO2...
77 FR 1947 - Agency Information Collection Activities: Jade Act
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-12
... technology; and (e) the annual costs burden to respondents or record keepers from the collection of... CBP Form 7501, Entry Summary, which serves as the importer's certification. In addition, at the time... Number of Annual Responses per Respondent: 20. Estimated Total Annual Responses: 443,940. Estimated Time...
Savoie, Jennifer G.; Mullaney, John R.; Bent, Gardner C.
2017-02-21
Trends in long-term water-quality and streamflow data from six water-quality-monitoring stations within three major river basins in Massachusetts and Rhode Island that flow into Narragansett Bay and Little Narragansett Bay were evaluated for water years 1979–2015. In this study, conducted by the U.S. Geological Survey in cooperation with the Rhode Island Department of Environmental Management, the Rhode Island Water Resources Board, and the U.S. Environmental Protection Agency, water-quality and streamflow data were evaluated with a Weighted Regressions on Time, Discharge, and Season smoothing method, which removes the effects of year-to-year variation in water-quality conditions due to variations in streamflow (discharge). Trends in annual mean, annual median, annual maximum, and annual 7-day minimum flows at four continuous streamgages were evaluated by using a time-series smoothing method for water years 1979–2015.Water quality at all monitoring stations changed over the study period. Decreasing trends in flow-normalized nutrient concentrations and loads were observed during the period at most monitoring stations for total nitrogen, nitrite plus nitrate, and total phosphorus. Average flow-normalized loads for water years 1979–2015 decreased in the Blackstone River by up to 46 percent in total nitrogen, 17 percent in nitrite plus nitrate, and 69 percent in total phosphorus. The other rivers also had decreasing flow-normalized trends in nutrient concentrations and loads, except for the Pawtuxet River, which had an increasing trend in nitrite plus nitrate. Increasing trends in flow-normalized chloride concentrations and loads were observed during the study period at all of the rivers, with increases of more than 200 percent in the Blackstone River.Small increasing trends in annual mean daily streamflow were observed in 3 of the 4 rivers, with increases of 1.2 to 11 percent; however, the trends were not significant. All 4 rivers had decreases in streamflow for the annual 7-day minimums, but only 3 of the 4 rivers had decreases that were significant (34 to 54 percent). The Branch River had decreasing annual mean daily streamflow (7.5 percent) and the largest decrease in the annual 7-day minimum streamflow. The Blackstone and Pawtuxet Rivers had the largest increases in annual maximum daily flows but had decreases in the annual 7-day minimum flows.
Liquid and Gaseous Waste Operations Department annual operating report CY 1996
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maddox, J.J.; Scott, C.B.
1997-03-01
This annual report summarizes operating activities dealing with the process waste system, the liquid low-level waste system, and the gaseous waste system. It also describes upgrade activities dealing with the process and liquid low-level waste systems, the cathodic protection system, a stack ventilation system, and configuration control. Maintenance activities are described dealing with nonradiological wastewater treatment plant, process waste treatment plant and collection system, liquid low-level waste system, and gaseous waste system. Miscellaneous activities include training, audits/reviews/tours, and environmental restoration support.
Patidar, Nitish; Weech-Maldonado, Robert; O'Connor, Stephen J; Sen, Bisakha; Trimm, J M Mickey; Camargo, Carlos A
Freestanding emergency departments (FSEDs) are fast growing entities in health care, delivering emergency care outside of hospitals. Hospitals may benefit in several ways by opening FSEDs. The study used the resource dependence theory as a means to analyze the relationship between market and organizational factors and the likelihood of hospitals to operate FSEDs. All acute care hospitals in 14 states with FSEDs present during the study period from 2002 to 2011. Data on FSEDs were merged with American Hospital Association Annual Survey, Centers for Medicare and Medicaid Services' Cost Reports, and Area Resource File data. The outcome variable consists of whether or not the hospital operates an FSED. Independent variables include per capita income, percent population over age of 65 years, primary care and specialist physicians per capita, urban location, change in the unemployment rate, change in the population, change in poverty level, market competition, total satellite and autonomous FSEDs in the market, Medicare-managed care penetration rate, hospital beds, total margin, and system membership. We used logistic regression analysis with state and year fixed effects. Standard errors in the regression were clustered by hospital. The number of hospitals operating satellite FSEDs increased from 32 (2.33%) in 2002 to 91 (5.76%) hospitals in 2011 among the 14 states included in the study sample. The results support the hypothesis that hospitals located in munificent environments and more competitive environments (presence of other FSEDs) are more likely to operate an FSED. Organizational level factors such as bed size and system membership are associated with a hospital operating an FSED. The findings may be used by policy makers in developing regulations for hospitals opening FSEDs. Also, study findings of this study may be used by hospitals to make informed decisions when formulating strategies regarding FSEDs.
Mullaney, John R.; Martin, Joseph W.; Morrison, Jonathan
2018-03-20
The daily and annual loads of nitrate plus nitrite and total nitrogen for the Connecticut River at Middle Haddam, Connecticut, were determined for water years 2009 to 2014. The analysis was done with a combination of methods, which included a predefined rating curve method for nitrate plus nitrite and total nitrogen for water years 2009 to 2011 and a custom rating curve method that included sensor measurements of nitrate plus nitrite nitrogen concentration and turbidity along with mean daily flow to determine total nitrogen loads for water years 2011 to 2014. Instantaneous concentrations of total nitrogen were estimated through the use of a regression model based on sensor measurements at 15-minute intervals of nitrate plus nitrite nitrogen and turbidity for water years 2011 to 2014.Annual total nitrogen loads at the Connecticut River at Middle Haddam ranged from 12,900 to 19,200 metric tons, of which about 42 to 49 percent was in the form of nitrate plus nitrite. The mean 95-percent prediction intervals on daily total nitrogen load estimates were smaller from the custom model, which used sensor data, than those calculated by the predefined model.Annual total nitrogen load estimates at the Connecticut River at Middle Haddam were compared with the upstream load estimates at the Connecticut River at Thompsonville, Conn. Annual gains in total nitrogen loads between the two stations ranged from 3,430 to 6,660 metric tons. These increases between the two stations were attributed to the effects of increased urbanization and to combined annual discharges of 1,540 to 2,090 metric tons of nitrogen from 24 wastewater treatment facilities in the drainage area between the two stations. The contribution of total nitrogen from wastewater discharge between the two stations had declined substantially before the beginning of this study and accounted for from 31 to 52 percent of the gain in nitrogen load between the Thompsonville and Middle Haddam sites.
Long-term dynamics of winter and summer annual communities in the Chihuahuan Desert
Guo, Q.; Brown, J.H.; Valone, T.J.
2002-01-01
Winter and summer annuals in the Chihuahuan Desert have been intensively studied in recent years but little is known about the similarities and differences in the dynamics between these two communities. Using 15 yr of census data from permanent quadrats, this paper compared the characteristics and temporal dynamics of these two distinct, spatially co-existent but temporally segregated communities. Although the total number of summer annual species recorded during our 15 yr of observation was higher than winter annuals, the mean number of species observed each year was higher in the winter community. The winter community exhibited lower temporal variation in total plant abundance and populations of individual species, lower species turnover rate and higher evenness than the summer community. The rank abundances of species in winter were significantly positively correlated for a period of up to 7 yr while in summer significant positive correlations in rank abundance disappeared after 2 to 3 yr. The higher seasonal species diversity (i.e. number of species observed in each season) in winter rather than the overall special pool (over 15 yr) may be responsible for the greater community stability of winter annuals. The difference in long-term community dynamics between the two communities of annual plants are likely due to the differences in total species pool, life history traits (e.g. seed size), and seasonal climatic regimes.
Puente, Celso; Atkins, John T.
1989-01-01
Meteorologic and hydrologic data from five small watersheds in the coal areas of West Virginia were used to calibrate and test the U.S. Geological Survey Precipitation-Runoff Modeling System for simulating streamflow under various climatic and land-use conditions. Three of the basins--Horsecamp Run, Gilmer Run, and Collison Creek--are primarily forested and relatively undisturbed. The remaining basins--Drawdy Creek and Brier Creek-are extensively mined, both surface and underground above stream drainage level. Low-flow measurements at numerous synoptic sites in the mined basins indicate that coal mining has substantially altered the hydrologic system of each basin. The effects of mining on streamflow that were identified are (1) reduced base flow in stream segments underlain by underground mines, (2) increased base flow in streams that are downdip and stratigraphically below the elevation of the mined coal beds, and (3) interbasin transfer of ground water through underground mines. These changes probably reflect increased permeability of surface rocks caused by subsidence fractures associated with collapsed underground mines in the basin. Such fractures would increase downward percolation of precipitation, surface and subsurface flow, and ground-water flow to deeper rocks or to underground mine workings. Model simulations of the water budgets for the unmined basins during the 1972-73 water years indicate that total annual runoff averaged 60 percent of average annual precipitation; annual evapotranspiration losses averaged 40 percent of average annual precipitation. Of the total annual runoff, approximately 91 percent was surface and subsurface runoff and 9 percent was groundwater discharge. Changes in storage in the soil zone and in the subsurface and ground-water reservoirs in the basins were negligible. In contrast, water-budget simulations for the mined basins indicate significant differences in annual recharge and in total annual runoff. Model simulations of the water budget for Drawdy Creek basin indicate that total annual runoff during 1972-73 averaged only 43 percent of average annual precipitation--the lowest of all study basins; annual evapotranspiration losses averaged 49 percent, and interbasin transfer of ground-water losses averaged about 8 percent. Of the total annual runoff, approximately 74 percent was surface and subsurface flow and 26 percent was ground-water discharge. The low total annual runoff at Drawdy Creek probably reflects increased recharge of precipitation and surface and subsurface flow losses to ground water. Most of the increase in ground-water storage is, in turn, lost to a ground-water sink--namely, interbasin transfer of ground water by gravity drainage and (or) mine pumpage from underground mines that extend to adjacent basins. Hypothetical mining situations were posed for model analysis to determine the effects of increased mining on streamflow in the mined basins. Results of model simulations indicate that streamflow characteristics, the water budget, and the seasonal distribution of streamflow would be significantly modified in response to an increase in mining in the basins. Simulations indicate that (1) total annual runoff in the basins would decrease because of increased surface- and subsurface-flow losses and increased recharge of precipitation to ground water (these losses would tend to reduce medium to high flows mainly during winter and spring when losses would be greatest), (2) extreme high flows in response to intense rainstorms would be negligibly affected, regardless of the magnitude of mining in the basins, (3) ground-water discharge also would decrease during winter and spring, but the amount and duration of low flows during summer and fall would substantially increase in response to increased ground-water storage in rocks and in underground mines, and (4) the increase in ground-water storage in the basins would be depleted, mostly by increased losses to a grou
Energy Data Management Manual for the Wastewater Treatment Sector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lemar, Paul; De Fontaine, Andre
Energy efficiency has become a higher priority within the wastewater treatment sector, with facility operators and state and local governments ramping up efforts to reduce energy costs and improve environmental performance. Across the country, municipal wastewater treatment plants are estimated to consume more than 30 terawatt hours per year of electricity, which equates to about $2 billion in annual electric costs. Electricity alone can constitute 25% to 40% of a wastewater treatment plant’s annual operating budget and make up a significant portion of a given municipality’s total energy bill. These energy needs are expected to grow over time, driven bymore » population growth and increasingly stringent water quality requirements. The purpose of this document is to describe the benefits of energy data management, explain how it can help drive savings when linked to a strong energy management program, and provide clear, step-by-step guidance to wastewater treatment plants on how to appropriately track energy performance. It covers the basics of energy data management and related concepts and describes different options for key steps, recognizing that a single approach may not work for all agencies. Wherever possible, the document calls out simpler, less time-intensive approaches to help smaller plants with more limited resources measure and track energy performance. Reviews of key, publicly available energy-tracking tools are provided to help organizations select a tool that makes the most sense for them. Finally, this document describes additional steps wastewater treatment plant operators can take to build on their energy data management systems and further accelerate energy savings.« less
Implementation of national practice guidelines to reduce waste and optimize patient value.
Langell, John T; Bledsoe, Amber; Vijaykumar, Sathya; Anderson, Terry; Zawalski, Ivy; Zimmerman, Joshua
2016-06-15
The financial health care crisis has provided the platform to drive operational improvements at US health care facilities. This has led to adoption of lean operation principles by many health care organizations as a means of eliminating waste and improving operational efficiencies and overall value to patients. We believe that standardized implementation of national practice guidelines can provide the framework to help to reduce financial waste. We analyzed our institutional preoperative electrocardiogram (ECG) ordering practices for patients undergoing elective surgery at our institution from February-March, 2012 to identify utilization and review compliance with American Heart Association guidelines. We then implemented an ECG ordering algorithm based on these guidelines and studied changes in ordering patterns, associated cost savings and hospital billing for the same period in 2013. From February-March 2012, 677 noncardiac surgical procedures were performed at our institution, and 312 (46.1%) had a preoperative ECG. After implementation of our evidence-based ECG ordering algorithm for the same period in 2013, 707 noncardiac surgical cases were performed, and 120 (16.9%) had a preoperative ECG. Preoperative ECG utilization dropped 63% with an annual institutional cost savings of $72,906 and $291,618 in total annual health care savings. Based on our data, US-wide implementation of our evidence-based ECG ordering algorithm could save the US health care system >$1,868,800,000 per year. Here, we demonstrate that standardized application of a national practice guideline can be used to eliminate nearly $2 billion per year in waste from the US health care system. Copyright © 2016 Elsevier Inc. All rights reserved.
Hydrology and water quality in 13 watersheds in Gwinnett County, Georgia, 2001–15
Aulenbach, Brent T.; Joiner, John K.; Painter, Jaime A.
2017-02-23
The U.S. Geological Survey (USGS), in cooperation with Gwinnett County Department of Water Resources, established a Long-Term Trend Monitoring (LTTM) program in 1996. The LTTM program is a comprehensive, long-term, water-quantity and water-quality monitoring program designed to document and analyze the hydrologic and water-quality conditions of selected watersheds in Gwinnett County, Georgia. Water-quality monitoring initially began in six watersheds and currently [2016] includes 13 watersheds.As part of the LTTM program, streamflow, precipitation, water temperature, specific conductance, and turbidity were measured every 15 minutes for water years 2001–15 at 12 of the 13 watershed monitoring stations and for water years 2010–15 at the other watershed. In addition, discrete water-quality samples were collected seasonally from May through October (summer) and November through April (winter), including one base-flow and three stormflow event composite samples, during the study period. Samples were analyzed for nutrients (nitrogen and phosphorus), total organic carbon, trace elements (total lead and total zinc), total dissolved solids, and total suspended sediment (total suspended solids and suspended-sediment concentrations). The sampling scheme was designed to identify variations in water quality both hydrologically and seasonally.The 13 watersheds were characterized for basin slope, population density, land use for 2012, and the percentage of impervious area from 2000 to 2014. Several droughts occurred during the study period—water years 2002, 2007–08, and 2011–12. Watersheds with the highest percentage of impervious areas had the highest runoff ratios, which is the portion of precipitation that occurs as runoff. Watershed base-flow indexes, the ratio of base-flow runoff to total runoff, were inversely correlated with watershed impervious area.Flood-frequency estimates were computed for 13 streamgages in the study area that have 10 or more years of annual peak flow data through water year 2015, using the expected moments algorithm to fit a Pearson Type III distribution to logarithms of annual peak flows. Kendall’s tau nonparametric test was used to determine the statistical significance of trends in the annual peak flows, with none of the 13 streamgages exhibiting significant trends.A comparison of base-flow and stormflow water-quality samples indicates that turbidity and concentrations of total ammonia plus organic nitrogen, total nitrogen, total phosphorus, total organic carbon, total lead, total zinc, total suspended solids, and suspended-sediment concentrations increased with increasing discharge at all watersheds. Specific conductance decreased during stormflow at all watersheds, and total dissolved solids concentrations decreased during stormflow at a few of the watersheds. Total suspended solids and suspended-sediment concentrations typically were two orders of magnitude higher in stormflow samples, turbidities were about 1.5 orders of magnitude higher, total phosphorus and total zinc were about one order of magnitude higher, and total ammonia plus organic nitrogen, total nitrogen, total organic carbon, and total lead were about twofold higher than in base-flow samples.Seasonality and long-term trends were identified for the period water years 2001–15 for 10 constituents—total nitrogen, total nitrate plus nitrite, total phosphorus, dissolved phosphorus, total organic carbon, total suspended solids, suspended-sediment concentration, total lead, total zinc, and total dissolved solids. Seasonal patterns were present in most watersheds for all constituents except total dissolved solids, and the watersheds had fairly similar patterns of higher concentrations in the summer and lower concentrations in the winter. A linear long-term trend analysis of residual concentrations from the flow-only load estimation model (without time-trend terms) identified significant trends in 67 of the 130 constituent-watershed combinations. Seventy percent of the significant trends were negative. Total organic carbon and total dissolved solids had predominantly positive trends. Total phosphorus, total suspended solids, suspended-sediment concentration, total lead, and total zinc had only negative trends. The other three constituents exhibited fewer trends, both positive and negative.Streamwater loads were estimated annually for the 13-year period water years 2003–15 for the same 10 constituents in the trend analysis. Loads were estimated using a regression-model-based approach developed by the USGS for the Gwinnett County LTTM program that accommodates the use of storm-event composited samples. Concentrations were modeled as a function of discharge, base flow, time, season, and turbidity to improve model predictions and reduce errors in load estimates. Total suspended solids annual loads have been identified in Gwinnett County’s Watershed Protection Plan for target performance criterion.Although the amount of annual runoff was the primary factor in variations in annual loads, climatic conditions (classified as dry, average, or wet) affected annual loads beyond what was attributed to climatic-related variations in annual runoff. Significant negative trends in loads were estimated for the combined area of the watersheds for all constituents except dissolved phosphorus, total organic carbon, and total dissolved solids. The trend analysis indicated that total suspended solids and suspended-sediment concentration loads in the study area were decreasing by 57,000 and 87,000 pounds per day per year, respectively.Variations in constituent yields between watersheds appeared to be related to various watershed characteristics. Suspended sediment (as either total suspended solids or suspended-sediment concentrations), along with constituents transported predominately in solid phase (total phosphorus, total organic carbon, total lead, and total zinc), and total dissolved solids typically had higher yields from watersheds that had high percentages of impervious areas or high basin slope. High total nitrogen yields were also associated with watersheds with high percentages of impervious areas. Low total nitrogen, total suspended solids, total lead, and total zinc yields appeared to be associated with watersheds that had a low percentage of high-density development.
New York City Police Department automated fuel monitoring system. Volume II: documentation report
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGrath, W.J.; McNamara, M.M.
1981-11-01
The New York City Police Department's (NYCPD) automated fuel monitoring system was designed and implemented for NYCPD as a major aspect of the Naval Underwater System Center's technology transfer program. The system, which is the largest of its kind installed to date, provides complete control of fuel usage for an agency with 4,000 motor vehicles and 25,000 vehicle operators, and can be scaled up or down to meet the needs of other governmental units. Estimated annual cost savings to NYCPD are $2,000,000. Other benefits of the new system are: (1) central control of fuel ordering and dispensing which ensures fewermore » sites out of fuel and for shorter periods; (2) less out-of-precinct travel because personnel do not have to go from site to site looking for gas; and (3) control of the total fuel operation, both for management and accounting purposes.« less
Contractor cuts solar gain with custom window curtain
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ingraham, R.
1985-04-22
A local energy services contractor, using a 210-foot motorized thermal curtain to deflect sunlight entering the windows, has reduced excessive heat gain at a racetrack clubhouse here, cutting air conditioning run-time by about 75%. Because Mobile Greyhound Park's clubhouse faces east, direct exposure to sunlight from dawn to afternoon race time, about 1 p.m., was bringing the indoor temperature to almost 100/sup 0/, according to Stan Norris, operations management for the contracting firm, Technical Energy Controls, Inc. Lowering the temperature to a comfortable level required running four Carrier Corporation air handling units, rated at a total of more than 170more » tons, for about eight hours, and annual energy bills were running at about $240,000, Norris said. With the aluminum foil-backed vinyl curtain, the air handling units need only operate two hours to bring temperatures to comfort levels.« less
The CERAD Neuropsychologic Battery Total Score and the progression of Alzheimer disease.
Rossetti, Heidi C; Munro Cullum, C; Hynan, Linda S; Lacritz, Laura H
2010-01-01
To establish the Consortium to Establish a Registry for Alzheimer's Disease (CERAD) neuropsychologic battery as a valid measure of cognitive progression in Alzheimer disease (AD) by deriving annualized CERAD Total Change Scores and corresponding confidence intervals in AD and controls from which to define clinically meaningful change. Subjects included 383 normal control (NC) and 655 AD subjects with serial data from the CERAD registry database. Annualized CERAD Total Change Scores were derived and Reliable Change Indexes (RCIs) calculated to establish statistically reliable change values. CERAD Change Scores were compared with annualized change scores from the Mini-Mental State Examination (MMSE), Clinical Dementia Rating Scale (CDR) Sum of Boxes, and Blessed Dementia Rating Scale (BDRS). For the CERAD Total Score, the AD sample showed significantly greater decline than the NC sample over the 4-year interval, with AD subjects declining an average of 22.2 points compared with the NCs' improving an average 2.8 points from baseline to last visit [Group x Time interaction [F(4,1031)=246.08, P<0.001)]. By Visit 3, the majority of AD subjects (65.2%) showed a degree of cognitive decline that fell outside the RCI. CERAD Change Scores significantly correlated (P<0.001) with MMSE (r=-0.66), CDR (r=-0.42), and BDRS (r=-0.38) change scores. Results support the utility of the CERAD Total Score as a measure of AD progression and provide comparative data for annualized change in CERAD Total Score and other summary measures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... stationary CI RICE 1 a. Change oil and filter every 500 hours of operation or annually, whichever comes first.2 b. Inspect air cleaner every 1,000 hours of operation or annually, whichever comes first, and... comes first, and replace as necessary.3 Minimize the engine's time spent at idle and minimize the engine...
Code of Federal Regulations, 2014 CFR
2014-07-01
... stationary CI RICE 1 a. Change oil and filter every 500 hours of operation or annually, whichever comes first.2 b. Inspect air cleaner every 1,000 hours of operation or annually, whichever comes first, and... comes first, and replace as necessary.3 Minimize the engine's time spent at idle and minimize the engine...
Communications systems technology assessment study. Volume 2: Results
NASA Technical Reports Server (NTRS)
Kelley, R. L.; Khatri, R. K.; Kiesling, J. D.; Weiss, J. A.
1977-01-01
The cost and technology characteristics are examined for providing special satellite services at UHF, 2.5 GHz, and 14/12 GHz. Considered are primarily health, educational, informational and emergency disaster type services. The total cost of each configuration including space segment, earth station, installation operation and maintenance was optimized to reduce the user's total annual cost and establish preferred equipment performance parameters. Technology expected to be available between now and 1985 is identified and comparisons made between selected alternatives. A key element of the study is a survey of earth station equipment updating past work in the field, providing new insight into technology, and evaluating production and test methods that can reduce costs in large production runs. Various satellite configurations were examined. The cost impact of rain attenuation at Ku-band was evaluated. The factors affecting the ultimate capacity achievable with the available orbital arc and available bandwidth were analyzed.
Saudi Arabia Country Analysis Brief
2014-01-01
Saudi Arabia is the world's largest holder of crude oil proved reserves and was the largest exporter of total petroleum liquids in 2013. In 2013, Saudi Arabia was the world's second-largest petroleum liquids producer behind the United States and was the world's second-largest crude oil producer behind Russia. Saudi Arabia's economy remains heavily dependent on petroleum. Petroleum exports accounted for 85% of total Saudi export revenues in 2013, according to the Organization of the Petroleum Exporting Countries (OPEC)'s Annual Statistical Bulletin 2014. With the largest oil projects nearing completion, Saudi Arabia is expanding its natural gas, refining, petrochemicals, and electric power industries. Saudi Arabia's oil and natural gas operations are dominated by Saudi Aramco, the national oil and gas company and the world's largest oil company in terms of production. Saudi Arabia's Ministry of Petroleum and Mineral Resources and the Supreme Council for Petroleum and Minerals have oversight of the oil and natural gas sector and Saudi Aramco.
Different incidences of knee arthroplasty in the Nordic countries
NiemeläInen, Mika J; MäKelä, Keijo T; Robertsson, Otto; W-Dahl, Annette; Furnes, Ove; Fenstad, Anne M; Pedersen, Alma B; Schrøder, Henrik M; Huhtala, Heini; Eskelinen, Antti
2017-01-01
Background and purpose The annual number of total knee arthroplasties (TKAs) has increased worldwide in recent years. To make projections regarding future needs for primaries and revisions, additional knowledge is important. We analyzed and compared the incidences among 4 Nordic countries Patients and methods Using Nordic Arthroplasty Register Association (NARA) data from 4 countries, we analyzed differences between age and sex groups. We included patients over 30 years of age who were operated with TKA or unicompartmental knee arthroplasty (UKA) during the period 1997–2012. The negative binomial regression model was used to analyze changes in general trends and in sex and age groups. Results The average annual increase in the incidence of TKA was statistically significant in all countries. The incidence of TKA was higher in women than in men in all 4 countries. It was highest in Finland in patients aged 65 years or more. At the end of the study period in 2012, Finland’s total incidence was double that of Norway, 1.3 times that of Sweden and 1.4 times that of Denmark. The incidence was lowest in the youngest age groups (< 65 years) in all 4 countries. The proportional increase in incidence was highest in patients who were younger than 65 years. Interpretation The incidence of knee arthroplasty steadily increased in the 4 countries over the study period. The differences between the countries were considerable, with the highest incidence in Finland. Patients aged 65 years or more contributed to most of the total incidence of knee arthroplasty. PMID:28056570
Corporate culture, compliance and railroad operating rules
DOT National Transportation Integrated Search
1997-12-01
A focus group was held at the 1996 Bi-annual Operating Rules Association meeting of North American railroads to discuss the : general issue of compliance and operating rules. Twelve operating rules officers participated, representing Class I, II, and...
CO2 Reduction Effect of the Utilization of Waste Heat and Solar Heat in City Gas System
NASA Astrophysics Data System (ADS)
Okamura, Tomohito; Matsuhashi, Ryuji; Yoshida, Yoshikuni; Hasegawa, Hideo; Ishitani, Hisashi
We evaluate total energy consumption and CO2 emissions in the phase of the city gas utilization system from obtaining raw materials to consuming the product. First, we develop a simulation model which calculates CO2 emissions for monthly and hourly demands of electricity, heats for air conditioning and hot-water in a typical hospital. Under the given standard capacity and operating time of CGS, energy consumption in the equipments is calculated in detail considering the partial load efficiency and the control by the temperature of exhaust heat. Then, we explored the optimal size and operation of city gas system that minimizes the life cycle CO2 emissions or total cost. The cost-effectiveness is compared between conventional co-generation, solar heat system, and hybrid co-generation utilizing solar heat. We formulate a problem of mixed integer programming that includes integral parameters that express the state of system devices such as on/off of switches. As a result of optimization, the hybrid co-generation can reduce annual CO2 emissions by forty-three percent compared with the system without co-generation. Sensitivity for the scale of CGS on CO2 reduction and cost is also analyzed.
47 CFR 1.981 - Reports, annual and semiannual.
Code of Federal Regulations, 2010 CFR
2010-10-01
... use of radio station facilities must submit annually an audited financial statement reflecting the... operation to date. (3) Analysis of the results obtained. (4) Copies of any published reports. (5) Need for...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1994-06-01
The U.S. Department of Energy, Nevada Operations Office (DOE/NV), Completion Report provides a summary of activities conducted at the Nevada Test Site (NTS) between October 1, 1992, and September 30, 1993, associated with Operation KLAXON. (In the past, each annual Completion Report dealt with a series of underground nuclear detonations; however, because no nuclear tests were conducted during FY 1993, this Report summarizes continuing nonnuclear and nuclear test readiness activities at the NTS sponsored by DOE/NV.) The report serves as a reference for those involved with the planning and execution of Operation KLAXON and also serves as a planning guidemore » for future operations. Information in the report covers the logistics and management of activities. Scientific information and data associated with NTS activities are presented in technical documents published by participating agencies. In September 1992, Congress legislated a nine-month moratorium on the testing of nuclear weapons. The bill also provided for a resumption of testing (with no more than five tests per year, or a total of 15 during the next three years) in July 1993, and mandated an end to nuclear testing, entirely, by 1996. President Bush signed the bill into law in October 1992.« less
Feasibility analysis for biomass cogeneration at the Fort Apache Timber Company
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whittier, J.; Hasse, S.; Tomberlin, G.
1996-12-31
The Fort Apache Timber Company (FATCO) is a wholly-owned tribal enterprise of the White Mountain Apache Tribe (WMAT). WMAT officials are concerned about fuel buildup on the forest floor and the potential for catastrophic forests fires. Cogeneration is viewed as one means to effectively utilize biomass from the forest to reduce the chance of forest fires. FATCO presently spends approximately $1.6 million per year for electricity service from Navopache Electric Cooperative, Inc. for three sites. Peak demand is approximately 3.9 MW and the annual load factor is slightly under 50 percent. The blended cost of electricity is approximately $0.089 /more » kWh at the main mill. Biomass resources for fuel purposes may be obtained both from mill operations and from the forest operations. For many years FATCO has burned its wood residues to supply steam for dry kilns. It is estimated that a total of 125,778 bone dry tons (bdt) per year are available for fuel. A twenty year economic analysis model was used to evaluate the cogeneration potential. The model performs annual cash flow calculations to arrive at three measures of economic vitality: (1) Net Present Value (NPV), (2) levelized cost per kWh, and (3) Year 2 Return on Investment (ROI). Results of the analysis are positive for several scenarios.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-05
... Fixed Flat Fee of $150 Per Qualified Member Per Bi-Annual Session for a Total Cost Per Member Per Year... flat fee of $150 per qualified member per bi-annual session for a total cost per member per year of... behalf, the FINRA costs are subsumed in the larger fee paid to FINRA for the provision of regulatory...
C. John Ralph
1991-01-01
Data from the annual Christmas Bird Count between 1939 and 1989, around Honolulu, on the island of Oahu during late December, were analyzed to discover the annual rates of change and possible competitive interactions of introduced and native land bird species. Both total number of species and total number of individuals increased over the period. The proportion of...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-09
... FEDERAL HOUSING FINANCE AGENCY [No. 2012-N-02] Notice of Annual Adjustment of the Cap on Average.... ACTION: Notice. SUMMARY: The Federal Housing Finance Agency (FHFA) has adjusted the cap on average total... statutory cap.\\2\\ The Bank Act was amended in 2008 to set the statutory cap at $1 billion and to require the...
Timber resource statistics for the Juneau inventory unit, Alaska, 1970.
Vernon J. LaBau; Willem W.S. Van Hees
1983-01-01
Statistics on forest area, total gross and net timber volumes, and annual net growth and mortality are presented for the 1970 timber inventory of the Juneau unit, Alaska. Estimates for commercial forest land area total 1.3 million acres (535 000 ha) with a net growing stock volume of 8.3 billion cubic feet (234 million m3), and annual net growth...
Analysis of the breakdown of the Antarctic circumpolar vortex using TOMS ozone data
NASA Technical Reports Server (NTRS)
Bowman, Kenneth P.
1987-01-01
Climatological analysis of data from the Total Ozone Mapping Spectrometer (TOMS) on the Nimbus 7 satellite has shown that the annual cycles of ozone are very different in the Arctic and Antarctic. The annual cycle in the Arctic is a relatively smooth annual sine wave; but in the Antarctic the circumpolar vortex breaks down rapidly during the Southern Hemisphere spring (September through November), producing a rapid rise in total ozone and a sawtooth-shaped annual cycle. The evolution of the Antarctic total ozone field during the vortex breakdown was studied by computing areally-integrated ozone amounts from the TOMS data. This technique avoids substantial difficulties with using zonally-averaged ozone amounts to study the asymmetric breakdown phenomenon. Variability of total ozone is found to be large both within an individual year and between different years. During the last decade monthly-mean total ozone values in the Antarctic during the springtime vortex breakdown period have decreased dramatically. The ozone-area statistics indicate that the decrease has resulted in part from changes in the timing of the vortex breakdown and resultant ozone increase, which have occurred later during recent years. Analysis of the spatial scales involved in the ozone transport and mixing that occur during the vortex breakdown is now underway. Reliable calculation of diagnostic quantities like areally-integrated ozone is possible only with the high-resolution, two-dimensional, daily coverage provided by the TOMS instrument.
Code of Federal Regulations, 2010 CFR
2010-07-01
... of an annual evaluation of a concessioner's performance may not occur until after the selection of the best proposal submitted in response to a prospectus, the Director will make an annual performance... performance evaluation. In the event the concessioner receives a second less than satisfactory annual...
25 CFR 514.5 - When must a tribe pay its annual fees?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false When must a tribe pay its annual fees? 514.5 Section 514.5 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR GENERAL PROVISIONS FEES § 514.5 When must a tribe pay its annual fees? Each gaming operation shall calculate the amount of fees...
25 CFR 514.5 - When must a tribe pay its annual fees?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false When must a tribe pay its annual fees? 514.5 Section 514.5 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR GENERAL PROVISIONS FEES § 514.5 When must a tribe pay its annual fees? Each gaming operation shall calculate the amount of fees...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-01
.... These provisions include LMRDA Title II financial reporting and disclosure requirements for labor.... The labor organization annual financial reports required by section 201(b) of the Act, 29 U.S.C. 431(b... financial condition and operations for its preceding fiscal year.'' The Form LM-2 Annual Report, the most...
Code of Federal Regulations, 2014 CFR
2014-04-01
... miles for residential students? 39.711 Section 39.711 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF... Transportation Miles § 39.711 How does a school calculate annual bus transportation miles for residential students? To calculate the total annual transportation miles for residential students, a school must use...
Code of Federal Regulations, 2012 CFR
2012-04-01
... miles for residential students? 39.711 Section 39.711 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF... Transportation Miles § 39.711 How does a school calculate annual bus transportation miles for residential students? To calculate the total annual transportation miles for residential students, a school must use...
Code of Federal Regulations, 2013 CFR
2013-04-01
... miles for residential students? 39.711 Section 39.711 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF... Transportation Miles § 39.711 How does a school calculate annual bus transportation miles for residential students? To calculate the total annual transportation miles for residential students, a school must use...
Code of Federal Regulations, 2010 CFR
2010-04-01
... miles for residential students? 39.711 Section 39.711 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF... Transportation Miles § 39.711 How does a school calculate annual bus transportation miles for residential students? To calculate the total annual transportation miles for residential students, a school must use...
Code of Federal Regulations, 2011 CFR
2011-04-01
... miles for residential students? 39.711 Section 39.711 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF... Transportation Miles § 39.711 How does a school calculate annual bus transportation miles for residential students? To calculate the total annual transportation miles for residential students, a school must use...
40 CFR 98.144 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... mineral mass fractions at least annually to verify the mass fraction data provided by the supplier of the... determine the annual average mass fraction for the carbonate-based mineral in each carbonate-based raw... calibrated scales or weigh hoppers. Total annual mass charged to glass melting furnaces at the facility shall...
40 CFR 98.144 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... mineral mass fractions at least annually to verify the mass fraction data provided by the supplier of the... Spectrometry (incorporated by reference, see § 98.7). (c) You must determine the annual average mass fraction... calibrated scales or weigh hoppers. Total annual mass charged to glass melting furnaces at the facility shall...
7 CFR 929.50 - Transfers of Sales Histories and Annual Allotments.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 8 2013-01-01 2013-01-01 false Transfers of Sales Histories and Annual Allotments... Regulations § 929.50 Transfers of Sales Histories and Annual Allotments. (a) Leases and sales of cranberry... occurs, sales history attributable to the acreage being leased shall remain with the lessor. (2) Total...
7 CFR 929.50 - Transfers of Sales Histories and Annual Allotments.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 8 2012-01-01 2012-01-01 false Transfers of Sales Histories and Annual Allotments... Regulations § 929.50 Transfers of Sales Histories and Annual Allotments. (a) Leases and sales of cranberry... occurs, sales history attributable to the acreage being leased shall remain with the lessor. (2) Total...
7 CFR 929.50 - Transfers of Sales Histories and Annual Allotments.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 8 2011-01-01 2011-01-01 false Transfers of Sales Histories and Annual Allotments... Regulations § 929.50 Transfers of Sales Histories and Annual Allotments. (a) Leases and sales of cranberry... occurs, sales history attributable to the acreage being leased shall remain with the lessor. (2) Total...
7 CFR 929.50 - Transfers of Sales Histories and Annual Allotments.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 8 2014-01-01 2014-01-01 false Transfers of Sales Histories and Annual Allotments... Regulations § 929.50 Transfers of Sales Histories and Annual Allotments. (a) Leases and sales of cranberry... occurs, sales history attributable to the acreage being leased shall remain with the lessor. (2) Total...
7 CFR 929.50 - Transfers of Sales Histories and Annual Allotments.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 8 2010-01-01 2010-01-01 false Transfers of Sales Histories and Annual Allotments... Regulations § 929.50 Transfers of Sales Histories and Annual Allotments. (a) Leases and sales of cranberry... occurs, sales history attributable to the acreage being leased shall remain with the lessor. (2) Total...
Minnesota Higher Education Facilities Authority: 1999 Annual Report.
ERIC Educational Resources Information Center
Minnesota Higher Education Facilities Authority, Saint Paul.
This annual report reviews fiscal year 1999 for institutions serviced by the Minnesota Higher Education Facilities Authority. The report notes a slight decline in new financing activity, although the $87.7 million financed during the 1999 fiscal year was the second highest annual total for the Authority. Following some introductory material, the…
Code of Federal Regulations, 2013 CFR
2013-04-01
... subsidiary of a registered management investment company need not file a semi-annual report on Form N-SAR if financial information with respect to that subsidiary is reported in the parent's semi-annual report on Form N-SAR. [54 FR 10321, Mar. 13, 1989] ...
Code of Federal Regulations, 2012 CFR
2012-04-01
... subsidiary of a registered management investment company need not file a semi-annual report on Form N-SAR if financial information with respect to that subsidiary is reported in the parent's semi-annual report on Form N-SAR. [54 FR 10321, Mar. 13, 1989] ...
Code of Federal Regulations, 2014 CFR
2014-04-01
... subsidiary of a registered management investment company need not file a semi-annual report on Form N-SAR if financial information with respect to that subsidiary is reported in the parent's semi-annual report on Form N-SAR. [54 FR 10321, Mar. 13, 1989] ...
Code of Federal Regulations, 2011 CFR
2011-04-01
... subsidiary of a registered management investment company need not file a semi-annual report on Form N-SAR if financial information with respect to that subsidiary is reported in the parent's semi-annual report on Form N-SAR. [54 FR 10321, Mar. 13, 1989] ...
Pima Community College Summary of 2000-2001 Student Enrollment.
ERIC Educational Resources Information Center
Attinasi, Louis; Hennessey, Brendan; Reece, Dee
This report summarizes the annual unduplicated headcount enrollment and the annual full-time student equivalents (FTSE) generated by students in credit classes and by completers of clock-hour programs during fiscal year 2000-2001 at Pima Community College (Arizona). Highlights include: (1) Pima's total annual unduplicated headcount was 65,221 and…
A cost analysis of family planning in Bangladesh.
Fiedler, J L; Day, L M
1997-01-01
This article presents a step-down cost analysis using secondary data sources from 26 Bangladesh non-government organizations (NGOs) providing family planning services under a US Agency for International Development-funded umbrella organization. The unit costs of the NGOs' Maternal-Child Health (MCH) clinics and community-based distribution (CBD) systems were calculated and found to be minimally different. Several simulations were conducted to investigate the impact of alternative cost-reduction measures. The more general financial analysis proved more insightful than the unit cost analysis in terms of identifying means by which to improve the efficiency of the family planning operations of these NGOs. The analysis revealed that 56 per cent of total expenditures in the two-tiered umbrella's organizational structure are incurred in management operations and overheads. Of the remaining 44 per cent of project expenditures, 39 per cent is spent on the CBD program and 5 per cent on the MCH clinics. Within the CBD program, most resources are spent providing 4 million contacts (two-thirds of the annual total) which do not involve contraceptive re-supply. The clinics devote more resources to providing MCH services than to providing family planning services. The findings suggest that significant savings could be generated by containing administrative costs, improving operational efficiency, and reducing unnecessary or redundant fieldworker contacts. The magnitude of the potential savings raises a fundamental question about the continued viability and sustainability of this supply-driven CBD strategy.
[Proposal of a costing method for the provision of sterilization in a public hospital].
Bauler, S; Combe, C; Piallat, M; Laurencin, C; Hida, H
2011-07-01
To refine the billing to institutions whose operations of sterilization are outsourced, a sterilization cost approach was developed. The aim of the study is to determine the value of a sterilization unit (one point "S") evolving according to investments, quantities processed, types of instrumentation or packaging. The time of preparation has been selected from all sub-processes of sterilization to determine the value of one point S. The time of preparation of sterilized large and small containers and pouches were raised. The reference time corresponds to one bag (equal to one point S). Simultaneously, the annual operating cost of sterilization was defined and divided into several areas of expenditure: employees, equipments and building depreciation, supplies, and maintenance. A total of 136 crossing times of containers were measured. Time to prepare a pouch has been estimated at one minute (one S). A small container represents four S and a large container represents 10S. By dividing the operating cost of sterilization by the total number of points of sterilization over a given period, the cost of one S can be determined. This method differs from traditional costing method in sterilizing services, considering each item of expenditure. This point S will be the base for billing of subcontracts to other institutions. Copyright © 2011 Elsevier Masson SAS. All rights reserved.
Joint variability of global runoff and global sea surface temperatures
McCabe, G.J.; Wolock, D.M.
2008-01-01
Global land surface runoff and sea surface temperatures (SST) are analyzed to identify the primary modes of variability of these hydroclimatic data for the period 1905-2002. A monthly water-balance model first is used with global monthly temperature and precipitation data to compute time series of annual gridded runoff for the analysis period. The annual runoff time series data are combined with gridded annual sea surface temperature data, and the combined dataset is subjected to a principal components analysis (PCA) to identify the primary modes of variability. The first three components from the PCA explain 29% of the total variability in the combined runoff/SST dataset. The first component explains 15% of the total variance and primarily represents long-term trends in the data. The long-term trends in SSTs are evident as warming in all of the oceans. The associated long-term trends in runoff suggest increasing flows for parts of North America, South America, Eurasia, and Australia; decreasing runoff is most notable in western Africa. The second principal component explains 9% of the total variance and reflects variability of the El Ni??o-Southern Oscillation (ENSO) and its associated influence on global annual runoff patterns. The third component explains 5% of the total variance and indicates a response of global annual runoff to variability in North Aflantic SSTs. The association between runoff and North Atlantic SSTs may explain an apparent steplike change in runoff that occurred around 1970 for a number of continental regions.
Maurer, Douglas K.; Watkins, Sharon A.; Burrowws, Robert L.
2004-01-01
Rapid population growth in Carson Valley has caused concern over the continued availability of water resources to sustain future growth. The U.S. Geological Survey, in cooperation with Douglas County, began a study to update estimates of water-budget components in Carson Valley for current climatic conditions. Data collected at 19 sites included 9 continuous records of tributary streamflows, 1 continuous record of outflow from the valley, and 408 measurements of 10 perennially flowing but ungaged drainages. These data were compiled and analyzed to provide updated computations and estimates of streamflows tributary to Carson Valley, 1990-2002. Mean monthly and annual flows were computed from continuous records for the period 1990-2002 for five streams, and for the period available, 1990-97, for four streams. Daily mean flow from ungaged drainages was estimated using multi-variate regressions of individual discharge measurements against measured flow at selected continuous gages. From the estimated daily mean flows, monthly and annual mean flows were calculated from 1990 to 2002. These values were used to compute estimates of mean monthly and annual flows for the ungaged perennial drainages. Using the computed and estimated mean annual flows, annual unit-area runoff was computed for the perennial drainages, which ranged from 0.30 to 2.02 feet. For the period 1990-2002, estimated inflow of perennial streams tributary to Carson Valley totaled about 25,900 acre-feet per year. Inflow computed from gaged perennial drainages totaled 10,300 acre-feet per year, and estimated inflow from ungaged perennial drainages totaled 15,600 acre-feet per year. The annual flow of perennial streams ranges from 4,210 acre-feet at Clear Creek to 450 acre-feet at Stutler Canyon Creek. Differences in unit-area runoff and in the seasonal timing of flow likely are caused by differences in geologic setting, altitude, slope, or aspect of the individual drainages. The remaining drainages are ephemeral and supply inflow to the valley floor only during spring runoff in wet years or during large precipitation events. Annual unit-area runoff for the perennial drainages was used to estimate inflow from ephemeral drainages totaling 11,700 acre-feet per year. The totaled estimate of perennial and ephemeral tributary inflows to Carson Valley is 37,600 acre-feet per year. Gaged perennial inflow is 27 percent of the total, ungaged perennial inflow is 42 percent, and ephemeral inflow is 31 percent. The estimate is from 50 to 60 percent greater than three previous estimates, one made for a larger area and similar to two other estimates made for larger areas. The combined uncertainty of the estimates totaled about 33 percent of the total inflow or about 12,000 acre-feet per year.
Karamlou, Tara; Diggs, Brian S; Person, Thomas; Ungerleider, Ross M; Welke, Karl F
2008-12-02
Surgery for grown-up (age > or = 18 years) patients with congenital heart disease (GUCH) is frequently performed by surgeons without specialization in pediatric heart surgery. We sought to define national practice patterns and to determine whether outcomes for GUCH patients are improved if they are treated by specialized pediatric heart surgeons (PHSs) compared with non-PHSs. We identified index cardiac procedures in patients with 12 congenital heart disease diagnostic groups using the Nationwide Inpatient Sample 1988 to 2003. PHSs were defined as surgeons whose annual practice volumes were made of >75% annual pediatric heart cases. GUCH operations were defined as operations within these 12 diagnoses occurring in patients > or =18 years of age. We identified 30,250 operations, yielding a national estimate of 152,277 +/- 7,875 operations. Of these, 111,816 +/- 7,456 (73%) were pediatric operations, and 40,461 +/- 1,365 (27%) were GUCH operations. PHSs performed 68% of pediatric operations in all diagnostic groups, whereas non-PHSs performed 95% of GUCH operations within the same diagnostic groups (P<0.0001). In-hospital death rates for GUCH patients operated on by PHSs were lower than death rates for GUCH patients operated on by non-PHSs (1.87% [95% CI, 0.62 to 3.13] versus 4.84% [95% CI, 4.30 to 5.38%]; P<0.0001). Survival advantage increased with increasing surgeon annual pediatric volume (P=0.0031). Pediatric patients within specific diagnostic groups are more likely to undergo operation by PHSs, whereas GUCH patients within the same diagnostic groups are more likely to undergo operation by non-PHSs. In-hospital death rates are lower for GUCH patients operated on by PHSs. GUCH patients should be encouraged to obtain surgical operation by PHS.
The relationship between safety net activities and hospital financial performance
2010-01-01
Background During the 1990's hospitals in the U.S were faced with cost containment charges, which may have disproportionately impacted hospitals that serve poor patients. The purposes of this paper are to study the impact of safety net activities on total profit margins and operating expenditures, and to trace these relationships over the 1990s for all U.S urban hospitals, controlling for hospital and market characteristics. Methods The primary data source used for this analysis is the Annual Survey of Hospitals from the American Hospital Association and Medicare Hospital Cost Reports for years 1990-1999. Ordinary least square, hospital fixed effects, and two-stage least square analyses were performed for years 1990-1999. Logged total profit margin and operating expenditure were the dependent variables. The safety net activities are the socioeconomic status of the population in the hospital serving area, and Medicaid intensity. In some specifications, we also included uncompensated care burden. Results We found little evidence of negative effects of safety net activities on total margin. However, hospitals serving a low socioeconomic population had lower expenditure raising concerns for the quality of the services provided. Conclusions Despite potentially negative policy and market changes during the 1990s, safety net activities do not appear to have imperiled the survival of hospitals. There may, however, be concerns about the long-term quality of the services for hospitals serving low socioeconomic population. PMID:20074367
76 FR 40713 - Agency Information Collection Extension
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-11
... Paperwork Reduction Act of 1995), intends to extend for three years, an information collection request with...) Annual Estimated Number of Respondents: 1817; (6) Annual Estimated Number of Total Responses: 1817; (7...
Nascimento, W S; Yamamoto, M E; Chellappa, N T; Rocha, O; Chellappa, S
2015-05-01
This work presents information regarding the biology and state of conservation of an endangered annual fish Hypsolebias antenori. Fish were captured from small seasonal pools located in Northeastern Brazil. The total body length, body mass, sex ratio, first sexual maturity were investigated. The sampled population showed sexual dimorphism. There was a predominance of females (60%) over males (40%) with a sex ratio of 1: 1.4 and males were bigger and heavier than the females. Amplitude of total length of males ranged from 2.6 to 7.1cm (4.1 ± 1.15) and that of females from 2.2 to 5.4 cm (3.6 ± 0.9). Amplitude of body mass of males varied from 0.25 to 7 g (1.3 g ± 1.4) and that of females from 0.12 to 2.1g (0.7 g ± 0.5). The total weight-length equation of males was Wt = 0.0108Lt3.172 with r = 0.9826 and of females was Wt = 0.0122Lt3.0114 with r = 0.9608. Females attained first sexual maturity at 3.2 cm (± 0.25) total length and males at 3.3 cm (± 0.08) total length. All temporary pools surveyed in Northeastern Brazil were in a high degree of degradation, suffering due to anthropogenic action. Reduced rainfall resulting from global climate change prevents the filling up of these pools, thus preventing the completion of the reproductive cycle of annual fishes. One factor hindering development of conservation strategies is limited literature on biology and conservation status of annual fishes. There is a need for conservation measures to protect annual fish populations, especially creation of protected areas in the Brazilian semiarid region.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-01
... reporting system designed to help State Administrative Agencies (SAAs) meet all reporting requirements as... annual costs to respondents operations and maintenance costs for technical services. There is no annual...
Rasmussen, Teresa J.; Ziegler, Andrew C.; Rasmussen, Patrick P.
2005-01-01
The lower Kansas River is an important source of drinking water for hundreds of thousands of people in northeast Kansas. Constituents of concern identified by the Kansas Department of Health and Environment (KDHE) for streams in the lower Kansas River Basin include sulfate, chloride, nutrients, atrazine, bacteria, and sediment. Real-time continuous water-quality monitors were operated at three locations along the lower Kansas River from July 1999 through September 2004 to provide in-stream measurements of specific conductance, pH, water temperature, turbidity, and dissolved oxygen and to estimate concentrations for constituents of concern. Estimates of concentration and densities were combined with streamflow to calculate constituent loads and yields from January 2000 through December 2003. The Wamego monitoring site is located 44 river miles upstream from the Topeka monitoring site, which is 65 river miles upstream from the DeSoto monitoring site, which is 18 river miles upstream from where the Kansas River flows into the Missouri River. Land use in the Kansas River Basin is dominated by grassland and cropland, and streamflow is affected substantially by reservoirs. Water quality at the three monitoring sites varied with hydrologic conditions, season, and proximity to constituent sources. Nutrient and sediment concentrations and bacteria densities were substantially larger during periods of increased streamflow, indicating important contributions from nonpoint sources in the drainage basin. During the study period, pH remained well above the KDHE lower criterion of 6.5 standard units at all sites in all years, but exceeded the upper criterion of 8.5 standard units annually between 2 percent of the time (Wamego in 2001) and 65 percent of the time (DeSoto in 2003). The dissolved oxygen concentration was less than the minimum aquatic-life-support criterion of 5.0 milligrams per liter less than 1 percent of the time at all sites. Dissolved solids, a measure of the dissolved material in water, exceeded 500 milligrams per liter about one-half of the time at the three Kansas River sites. Larger dissolved-solids concentrations upstream likely were a result of water inflow from the highly mineralized Smoky Hill River that is diluted by tributary flow as it moves downstream. Concentrations of total nitrogen and total phosphorus at the three monitoring sites exceeded the ecoregion water-quality criteria suggested by the U.S. Environmental Protection Agency during the entire study period. Median nitrogen and phosphorus concentrations were similar at all three sites, and nutrient load increased moving from the upstream to downstream sites. Total nitrogen and total phosphorus yields were nearly the same from site to site indicating that nutrient sources were evenly distributed throughout the lower Kansas River Basin. About 11 percent of the total nitrogen load and 12 percent of the total phosphorus load at DeSoto during 2000-03 originated from wastewater-treatment facilities. Escherichia coli bacteria densities were largest at the middle site, Topeka. On average, 83 percent of the annual bacteria load at DeSoto during 2000-03 occurred during 10 percent of the time, primarily in conjunction with runoff. The average annual sediment loads at the middle and downstream monitoring sites (Topeka and DeSoto) were nearly double those at the upstream site (Wamego). The average annual sediment yield was largest at Topeka. On average, 64 percent of the annual suspended-sediment load at DeSoto during 2000-03 occurred during 10 percent of the time. Trapping of sediment by reservoirs located on contributing tributaries decreases transport of sediment and sediment-related constituents. The average annual suspended-sediment load in the Kansas River at DeSoto during 2000-03 was estimated at 1.66 million tons. An estimated 13 percent of this load consisted of sand-size particles, so approximately 216,000 tons of sand were transported
Third Annual Workshop on Space Operations Automation and Robotics (SOAR 1989)
NASA Technical Reports Server (NTRS)
Griffin, Sandy (Editor)
1990-01-01
Papers presented at the Third Annual Workshop on Space Operations Automation and Robotics (SOAR '89), hosted by the NASA Lyndon B. Johnson Space Center at Houston, Texas, on July 25 to 27, 1989, are given. Approximately 100 technical papers were presented by experts from NASA, the USAF, universities, and technical companies. Also held were panel discussions on Air Force/NASA Artificial Intelligence Overview and Expert System Verification and Validation.
Treatment of Early Post-op Wound Infection after Internal Fixation
2015-10-01
Obremskey, M.D. CONTRACTING ORGANIZATION: Vanderbilt University Medical Center Nashville TN 37203 REPORT DATE: October 2015 TYPE OF REPORT: Annual...PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YYYY) October 2015 2. REPORT TYPE Annual 3. DATES COVERED (From - To...either: (Group 1) operative debridement and PO antibiotic treatment for 6 weeks; or (Group 2) operative debridement and IV antibiotics for 6 weeks and
Analytical expressions for maximum wind turbine average power in a Rayleigh wind regime
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carlin, P.W.
Average or expectation values for annual power of a wind turbine in a Rayleigh wind regime are calculated and plotted as a function of cut-out wind speed. This wind speed is expressed in multiples of the annual average wind speed at the turbine installation site. To provide a common basis for comparison of all real and imagined turbines, the Rayleigh-Betz wind machine is postulated. This machine is an ideal wind machine operating with the ideal Betz power coefficient of 0.593 in a Rayleigh probability wind regime. All other average annual powers are expressed in fractions of that power. Cases consideredmore » include: (1) an ideal machine with finite power and finite cutout speed, (2) real machines operating in variable speed mode at their maximum power coefficient, and (3) real machines operating at constant speed.« less
Cost of illness among patients with diabetic foot ulcer in Turkey
Oksuz, Ergun; Malhan, Simten; Sonmez, Bilge; Numanoglu Tekin, Rukiye
2016-01-01
AIM To evaluate the annual cost of patients with Wagner grade 3-4-5 diabetic foot ulcer (DFU) from the public payer’s perspective in Turkey. METHODS This study was conducted focused on a time frame of one year from the public payer’s perspective. Cost-of-illness (COI) methodology, which was developed by the World Health Organization, was used in the generation of cost data. By following a clinical path with the COI method, the main total expenses were reached by multiplying the number of uses of each expense item, the percentage of cases that used them and unit costs. Clinical guidelines and real data specific to Turkey were used in the calculation of the direct costs. Monte Carlo Simulation was used in the study as a sensitivity analysis. RESULTS The following were calculated in DFU treatment from the public payer’s perspective: The annual average per patient outpatient costs $579.5 (4.1%), imaging test costs $283.2 (2.0%), laboratory test costs $284.8 (2.0%), annual average per patient cost of intervention, rehabilitation and trainings $2291.7 (16.0%), annual average per patient cost of drugs used $2545.8 (17.8%) and annual average per patient cost of medical materials used in DFU treatment $735.0 (5.1%). The average annual per patient cost for hospital admission is $7357.4 (51.5%). The average per patient complication cost for DFU is $210.3 (1.5%). The average annual per patient cost of DFU treatment in Turkey is $14287.70. As a result of the sensitivity analysis, the standard deviation of the analysis was $5706.60 (n = 5000, mean = $14146.8, 95%CI: $13988.6-$14304.9). CONCLUSION The health expenses per person are $-PPP 1045 in 2014 in Turkey and the average annual per patient cost for DFU is 14-fold of said amount. The total health expense in 2014 in Turkey is $-PPP 80.3 billion and the total DFU cost has a 3% share in the total annual health expenses for Turkey. Hospital costs are the highest component in DFU disease costs. In order to prevent DFU, training of the patients at risk and raising consciousness in patients with diabetes mellitus (DM) will provide benefits in terms of economy. Appropriate and efficient treatment of DM is a health intervention that can prevent complications. PMID:27795820
Early pruning affects 15-year growth of cottonwood planted at 40- by 40-foot spacing
James S. Meadows; Roger M. Krinard
2013-01-01
We compared the growth of eastern cottonwood (Populus deltoides Bartr. ex Marsh.) trees planted at 40- by 40-foot spacing and subjected to four pruning treatments from the 2nd through the 8th year of growth. Treatments were (1) no pruning, (2) prune to one-third of total height annually, (3) prune to one-half of total height annually, and (4) prune...
Sex-related trends in participation and performance in the 'Swiss Bike Masters' from 1994-2012.
Gloor, Roman Urs; Knechtle, Beat; Knechtle, Patrizia; Rüst, Christoph Alexander; Haupt, Samuel; Rosemann, Thomas; Lepers, Romuald
2013-04-01
General participation in contests such as ultra-marathons and ultra-triathlons has increased considerably over the past 30 years, especially among women. This study investigated performance trends in the Swiss Bike Masters, one of the first and most prestigious mountain bike, ultra-endurance races in its class, with comparisons of participation and performance trends to similar races. The development of performance in the Swiss Bike Masters held between 1994 and 2012 was investigated by analysing the number of finishers, their age, sex, and cycling speed. Between 1994 and 2009, the athletes had to cover 120 kilometers with a total difference in altitude of 5,000 meters. Since 2010, the race distance was shortened to 105 kilometers and the total difference in altitude was reduced to 4,400 meters. The total men participating and total finishing decreased significantly, while women's participation has remained low. The age of the annual winners and the annual top three finishers showed no changes over time. Performances of the annual fastest women improved, while performances of the annual fastest men remained unchanged. To summarize, rate of finishing has decreased for men and has been stable, but low, among women. The sex difference in cycling speed for the best cyclists has decreased across the years.
Exposures to Transit and Other Sources of Noise among New York City Residents
Neitzel, Richard L.; Gershon, Robyn R. M.; McAlexander, Tara P.; Magda, Lori A.; Pearson, Julie M.
2015-01-01
To evaluate the contributions of common noise sources to total annual noise exposures among urban residents and workers, we estimated exposures associated with five common sources (use of mass transit, occupational and non-occupational activities, MP3 player and stereo use, and time at home and doing other miscellaneous activities) among a sample of over 4500 individuals in New York City (NYC). We then evaluated the contributions of each source to total noise exposure and also compared our estimated exposures to the recommended 70 dBA annual exposure limit. We found that one in ten transit users had noise exposures in excess of the recommended exposure limit from their transit use alone. When we estimated total annual exposures, 90% of NYC transit users and 87% of nonusers exceeded the recommended limit. MP3 player and stereo use, which represented a small fraction of the total annual hours for each subject on average, was the primary source of exposure among the majority of urban dwellers we evaluated. Our results suggest that the vast majority of urban mass transit riders may be at risk of permanent, irreversible noise-induced hearing loss and that, for many individuals, this risk is driven primarily by exposures other than occupational noise. PMID:22088203
Has Medicare Part D Reduced Racial/Ethnic Disparities in Prescription Drug Use and Spending?
Mahmoudi, Elham; Jensen, Gail A
2014-01-01
Objective To evaluate whether Medicare Part D has reduced racial/ethnic disparities in prescription drug utilization and spending. Data Nationally representative data on white, African American, and Hispanic Medicare seniors from the 2002–2009 Medical Expenditure Panel Survey are analyzed. Five measures are examined: filling any prescriptions during the year, the number of prescriptions filled, total annual prescription spending, annual out-of-pocket prescription spending, and average copay level. Study Design We apply the Institute of Medicine's definition of a racial/ethnic disparity and adopt a difference-in-difference-in-differences (DDD) estimator using a multivariate regression framework. The treatment group consists of Medicare seniors, the comparison group, adults without Medicare aged 55–63 years. Principal Findings Difference-in-difference-in-differences estimates suggest that for African Americans Part D increased the disparity in annual spending on prescription drugs by $258 (p = .011), yet had no effect on other measures of prescription drug disparities. For Hispanics, DDD estimates suggest that the program reduced the disparities in annual number of prescriptions filled, annual total and out-of-pocket spending on prescription drugs by 2.9 (p = .077), $282 (p = .019) and $143 (p < .001), respectively. Conclusion Medicare Part D had mixed effects. Although it reduced Hispanic/white disparities related to prescription drugs among seniors, it increased the African American/white disparity in total annual spending on prescription drugs. PMID:24102408
Code of Federal Regulations, 2011 CFR
2011-04-01
..., Annual Electric Balancing Authority Area and Planning Area Report. 141.51 Section 141.51 Conservation of...) § 141.51 FERC Form No. 714, Annual Electric Balancing Authority Area and Planning Area Report. (a) Who... Policies Act, 16 U.S.C. 2602, operating a balancing authority area, and any group of electric utilities...
Code of Federal Regulations, 2013 CFR
2013-04-01
..., Annual Electric Balancing Authority Area and Planning Area Report. 141.51 Section 141.51 Conservation of...) § 141.51 FERC Form No. 714, Annual Electric Balancing Authority Area and Planning Area Report. (a) Who... Policies Act, 16 U.S.C. 2602, operating a balancing authority area, and any group of electric utilities...
Code of Federal Regulations, 2012 CFR
2012-04-01
..., Annual Electric Balancing Authority Area and Planning Area Report. 141.51 Section 141.51 Conservation of...) § 141.51 FERC Form No. 714, Annual Electric Balancing Authority Area and Planning Area Report. (a) Who... Policies Act, 16 U.S.C. 2602, operating a balancing authority area, and any group of electric utilities...
Code of Federal Regulations, 2010 CFR
2010-04-01
..., Annual Electric Balancing Authority Area and Planning Area Report. 141.51 Section 141.51 Conservation of...) § 141.51 FERC Form No. 714, Annual Electric Balancing Authority Area and Planning Area Report. (a) Who... Policies Act, 16 U.S.C. 2602, operating a balancing authority area, and any group of electric utilities...
Code of Federal Regulations, 2014 CFR
2014-04-01
..., Annual Electric Balancing Authority Area and Planning Area Report. 141.51 Section 141.51 Conservation of...) § 141.51 FERC Form No. 714, Annual Electric Balancing Authority Area and Planning Area Report. (a) Who... Policies Act, 16 U.S.C. 2602, operating a balancing authority area, and any group of electric utilities...
Deacon, Jeffrey R.; Smith, Thor E.; Johnston, Craig M.; Moore, Richard B.; Blake, Laura J.; Weidman, Rebecca M.
2006-01-01
A study of total nitrogen concentrations and loads was conducted from December 2002 to September 2005 at 13 river sites in the upper Connecticut River Basin. Ten sites were selected to represent contributions of nitrogen from forested, agricultural, and urban land. Three sites were distributed spatially on the main stem of the Connecticut River to assess the cumulative total nitrogen loads. To further improve the understanding of the sources and concentrations and loads of total nitrogen in the upper Connecticut River Basin, ambient surface water-quality sampling was supplemented with sampling of effluent from 19 municipal and paper mill wastewater-treatment facilities. Mean concentrations of total nitrogen ranged from 0.19 to 2.8 milligrams per liter (mg/L) at river sampling sites. Instantaneous mean loads of total nitrogen ranged from 162 to 58,300 pounds per day (lb/d). Estimated mean annual loads of total nitrogen ranged from 49,100 to 21.6 million pounds per year (lb/yr) with about 30 to 55 percent of the loads being transported during the spring. The estimated mean annual yields of total nitrogen ranged from 1,190 to 7,300 pounds per square mile per year (lb/mi2)/yr. Mean concentrations of total nitrogen ranged from 4.4 to 30 mg/L at wastewater-treatment sampling sites. Instantaneous mean loads of total nitrogen from municipal wastewater-treatment facilities ranged from 36 to 1,780 lb/d. Instantaneous mean loads of total nitrogen from paper mill wastewater-treatment facilities ranged from 96 to 160 lb/d. The median concentration of total nitrogen was 0.24 mg/L at forested sites, 0.48 mg/L at agricultural sites, 0.54 mg/L at urban sites, 0.48 mg/L at main-stem sites, and 14 mg/L at wastewater-treatment sites. Concentrations of total nitrogen at forested sites were significantly less than at all other site types (p0.05) but were significantly greater (p<0.05) than at forested sites and significantly less than concentrations at wastewater-treatment sites (p<0.05). Total nitrogen concentrations at wastewater-treatment sites were significantly different from all other site types (p<0.05). Annual yields of total nitrogen ranged from 732 to 1,920 (lb/mi2)/yr at forested sites; 1,550 to 2,980 (lb/mi2)/yr at agricultural sites; 1,280 to 1,860 (lb/mi2)/yr at urban sites that were not directly affected by wastewater effluent; 7,090 to 7,770 (lb/mi2)/yr at an urban site directly affected by wastewater effluent; and 1,300 to 2,390 (lb/mi2)/yr at main-stem sites. In this study, the mean annual load and yield of total nitrogen at the Connecticut River at Wells River, VT, was estimated at 4.47 million lb/yr and 1,690 (lb/mi2)/yr, respectively. The mean annual load and yield of total nitrogen at the Connecticut River at North Walpole, NH, was estimated at 9.60 million lb/yr and 1,750 (lb/mi2)/yr, respectively. The mean annual load and yield of total nitrogen leaving the upper Connecticut River Basin, as estimated at the Connecticut River at Thompsonville, CT, was 21.6 million lb/yr and 2,230 (lb/mi2)/yr, respectively.
The economic burden of human papillomavirus-related precancers and cancers in Sweden
Silfverschiöld, Maria; Greiff, Lennart; Asciutto, Christine; Wennerberg, Johan; Lydryp, Marie-Louise; Håkansson, Ulf; Sparén, Pär; Borgfeldt, Christer
2017-01-01
Background High-risk (HR) human papillomavirus (HPV) infection is an established cause of malignant disease. We used a societal perspective to estimate the cost of HR HPV-related cervical, vulvar, vaginal, anal, and penile precancer and cancer, and oropharyngeal cancer in Sweden in 2006, 1 year before HPV vaccination became available in the country. Materials and methods This prevalence-based cost-of-illness study used diagnosis-specific data from national registries to determine the number of HR HPV-related precancers and cancers. The HR HPV-attributable fractions of these diseases were derived from a literature review and applied to the total burden to estimate HR HPV-attributable costs. Direct costs were based on health care utilization and indirect costs on loss of productivity due to morbidity (i.e., sick leave and early retirement) and premature mortality. Results The total annual cost of all HR HPV-attributable precancers and cancers was €94 million (€10.3/inhabitant). Direct costs accounted for €31.3 million (€3.4/inhabitant) of the total annual cost, and inpatient care amounted to €20.7 million of direct costs. Indirect costs made up €62.6 million (€6.9/inhabitant) of the total annual cost, and premature mortality amounted to €36 million of indirect costs. Cervical precancer and cancer was most costly (total annual cost €58.4 million). Among cancers affecting both genders, anal precancer and cancer, and oropharyngeal cancer were the most costly (€11.2 million and €11.9 million, respectively). For oropharyngeal cancer, males had the highest health care utilization and represented 71% of the total annual cost. Penile precancer and cancer was least costly (€2.6 million). Conclusion The economic burden of HR HPV-related precancers and cancers is substantial. The disease-related management and treatment costs we report are relevant as a point of reference for future economic evaluations investigating the overall benefits of HPV vaccination in females and males in Sweden. PMID:28651012
25 CFR 39.710 - How does a school calculate annual bus transportation miles for day students?
Code of Federal Regulations, 2010 CFR
2010-04-01
... miles for day students? 39.710 Section 39.710 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE... Miles § 39.710 How does a school calculate annual bus transportation miles for day students? To calculate the total annual bus transportation miles for day students, a school must use the appropriate...
25 CFR 39.710 - How does a school calculate annual bus transportation miles for day students?
Code of Federal Regulations, 2012 CFR
2012-04-01
... miles for day students? 39.710 Section 39.710 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE... Miles § 39.710 How does a school calculate annual bus transportation miles for day students? To calculate the total annual bus transportation miles for day students, a school must use the appropriate...
25 CFR 39.710 - How does a school calculate annual bus transportation miles for day students?
Code of Federal Regulations, 2013 CFR
2013-04-01
... miles for day students? 39.710 Section 39.710 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE... Miles § 39.710 How does a school calculate annual bus transportation miles for day students? To calculate the total annual bus transportation miles for day students, a school must use the appropriate...
25 CFR 39.710 - How does a school calculate annual bus transportation miles for day students?
Code of Federal Regulations, 2011 CFR
2011-04-01
... miles for day students? 39.710 Section 39.710 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE... Miles § 39.710 How does a school calculate annual bus transportation miles for day students? To calculate the total annual bus transportation miles for day students, a school must use the appropriate...
25 CFR 39.710 - How does a school calculate annual bus transportation miles for day students?
Code of Federal Regulations, 2014 CFR
2014-04-01
... miles for day students? 39.710 Section 39.710 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE... Miles § 39.710 How does a school calculate annual bus transportation miles for day students? To calculate the total annual bus transportation miles for day students, a school must use the appropriate...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-22
... and cost. DATES: Additional comments may be submitted on or before March 23, 2012. ADDRESSES: Submit... section 271.23. State program revision may be necessary when the controlling Federal or State statutory or... Total Annual Cost: $680,790, which includes $680,790 annualized labor costs and $0 annualized capital or...
CUECost workbook development documentation
This is a user's manual for the Coal Utility Environmental Cost (CUECost) workbook to estimate installed capital and annualized costs. The CUECost workbook produces rough-order-of-magnitude (ROM) cost estimates (+/-30% accuracy) of the installed capital and annualized operating c...
76 FR 11679 - Drawbridge Operation Regulation; Sacramento River, Sacramento, CA
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-03
... 7th Annual Shamrock Half Marathon. This deviation allows the bridge to remain in the closed-to... March 13, 2011 to allow the community to participate in the 7th Annual Shamrock Half Marathon. This...
77 FR 10372 - Drawbridge Operation Regulation; Sacramento River, Sacramento, CA
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-22
... 8th Annual Shamrock Half Marathon. This deviation allows the bridge to remain in the closed-to... March 11, 2012 to allow the community to participate in the 8th Annual Shamrock Half Marathon. This...
Theoretical and experimental researches on the operating costs of a wastewater treatment plant
NASA Astrophysics Data System (ADS)
Panaitescu, M.; Panaitescu, F.-V.; Anton, I.-A.
2015-11-01
Purpose of the work: The total cost of a sewage plants is often determined by the present value method. All of the annual operating costs for each process are converted to the value of today's correspondence and added to the costs of investment for each process, which leads to getting the current net value. The operating costs of the sewage plants are subdivided, in general, in the premises of the investment and operating costs. The latter can be stable (normal operation and maintenance, the establishment of power) or variables (chemical and power sludge treatment and disposal, of effluent charges). For the purpose of evaluating the preliminary costs so that an installation can choose between different alternatives in an incipient phase of a project, can be used cost functions. In this paper will be calculated the operational cost to make several scenarios in order to optimize its. Total operational cost (fixed and variable) is dependent global parameters of wastewater treatment plant. Research and methodology: The wastewater treatment plant costs are subdivided in investment and operating costs. We can use different cost functions to estimate fixed and variable operating costs. In this study we have used the statistical formulas for cost functions. The method which was applied to study the impact of the influent characteristics on the costs is economic analysis. Optimization of plant design consist in firstly, to assess the ability of the smallest design to treat the maximum loading rates to a given effluent quality and, secondly, to compare the cost of the two alternatives for average and maximum loading rates. Results: In this paper we obtained the statistical values for the investment cost functions, operational fixed costs and operational variable costs for wastewater treatment plant and its graphical representations. All costs were compared to the net values. Finally we observe that it is more economical to build a larger plant, especially if maximum loading rates are reached. The actual target of operational management is to directly implement the presented cost functions in a software tool, in which the design of a plant and the simulation of its behaviour are evaluated simultaneously.
Watershed Effects on Streamflow Quantity and Quality in Six Watersheds of Gwinnett County, Georgia
Landers, Mark N.; Ankcorn, Paul D.; McFadden, Keith W.
2007-01-01
Watershed management is critical for the protection and enhancement of streams that provide multiple benefits for Gwinnett County, Georgia, and downstream communities. Successful watershed management requires an understanding of how stream quality is affected by watershed characteristics. The influence of watershed characteristics on stream quality is complex, particularly for the nonpoint sources of pollutants that affect urban watersheds. The U.S. Geological Survey (USGS), in cooperation with Gwinnett County Department of Water Resources (formerly known as Public Utilities), established a water-quality monitoring program during late 1996 to collect comprehensive, consistent, high-quality data for use by watershed managers. Between 1996 and 2003, more than 10,000 analyses were made for more than 430 water-quality samples. Continuous-flow and water-quality data have been collected since 1998. Loads have been computed for selected constituents from 1998 to 2003. Changing stream hydrology is a primary driver for many other water-quality and aquatic habitat effects. Primary factors affecting stream hydrology (after watershed size and climate) within Gwinnett County are watershed slope and land uses. For the six study watersheds in Gwinnett County, watershedwide imperviousness up to 12 percent does not have a well-defined influence on stream hydrology, whereas two watersheds with 21- and 35-percent impervious area are clearly impacted. In the stream corridor, however, imperviousness from 1.6 to 4.4 percent appears to affect baseflow and stormflow for all six watersheds. Relations of concentrations to discharge are used to develop regression models to compute constituent loads using the USGS LOAD ESTimator model. A unique method developed in this study is used to calibrate the model using separate baseflow and stormflow sample datasets. The method reduced model error and provided estimates of the load associated with the baseflow and stormflow parts of the hydrograph. Annual load of total suspended sediment is a performance criterion in Gwinnett County's Watershed Protection Plan. Median concentrations of total suspended solids in stormflow range from 30 to 180 times greater than in baseflow. This increase in total suspended solids concentration with increasing discharge has a multiplied effect on total suspended solids load, 97 to 99 percent of which is transported during stormflow. Annual total suspended solids load is highly dependent on annual precipitation; between 1998 and 2003 load for the wettest year was up to 28 times greater than for the driest year. Average annual total suspended solids yield from 1998-2003 in the six watersheds increased with high-density and transportation/utility land uses, and generally decreased with low-density residential, estate/park, and undeveloped land uses. Watershed characteristics also were related to annual loads of total phosphorus, dissolved phosphorus, total nitrogen, total dissolved solids, biochemical oxygen demand, and total zinc, as well as stream alkalinity. Flow-adjusted total suspended solids, total phosphorus, and total zinc stormflow concentrations between 1996 and 2003 have a seasonal pattern in five of the six watersheds. Flow-adjusted concentrations typically peak during late summer, between July and August. The seasonal pattern is stronger for more developed watersheds and may be related to seasonal land-disturbance activities and/or to seasonal rainfall intensity, both of which increase in summer. Adjusting for seasonality in the computation of constituent load caused the standard error of annual total suspended solids load to improve by an average of 11 percent, and increased computed summer total suspended solids loads by an average of 45 percent and decreased winter total suspended solids loads by an average of 40 percent. Total annual loads changed by less than 5 percent on the average. Graphical and statistical analyses do not indicate a time tre
NASA Technical Reports Server (NTRS)
Nainiger, J. J.; Burns, R. K.; Easley, A. J.
1982-01-01
A performance and operational economics analysis is presented for an integrated-gasifier, combined-cycle (IGCC) system to meet the steam and baseload electrical requirements. The effect of time variations in steam and electrial requirements is included. The amount and timing of electricity purchases from sales to the electric utility are determined. The resulting expenses for purchased electricity and revenues from electricity sales are estimated by using an assumed utility rate structure model. Cogeneration results for a range of potential IGCC cogeneration system sizes are compared with the fuel consumption and costs of natural gas and electricity to meet requirements without cogeneration. The results indicate that an IGCC cogeneration system could save about 10 percent of the total fuel energy presently required to supply steam and electrical requirements without cogeneration. Also for the assumed future fuel and electricity prices, an annual operating cost savings of 21 percent to 26 percent could be achieved with such a cogeneration system. An analysis of the effects of electricity price, fuel price, and system availability indicates that the IGCC cogeneration system has a good potential for economical operation over a wide range in these assumptions.
Operational experience with intermediate flat-plate photovoltaic systems
NASA Astrophysics Data System (ADS)
Risser, V. V.; Zwibel, H. S.
Operating features, data acquisition, and fault isolation and maintenance procedures at 20 kWp and 100 kWp photovoltaic (PV) installations in Texas and New Mexico are discussed. Weather and system performance are sensed each minute, averages are calculated for each ten readings, and data is stored on magnetic tape. A total of 84 parameters, including 64 string currents, are recorded at the 20 kWp array and 84 parameters, with 42 string currents, are traced in New Mexico. The 20 kW array is coupled to a 197 MW utility power plant, which determines the voltage of the array. It produced 12 MWh in one yr of operation, functioning at 24 pct overall efficiency. The 100 kWp system is coupled to a 60 kW power conditioning unit and feeds a shopping center, producing 8 pct of the annual load with a cap factor of 25 pct and 192 MWh of dc current produced in one year. It was found that under normal conditions washing the panels is not economically justified in terms of the small power lost if washing does not occur. It is concluded that the PV arrays can be successfully used in an automated operation mode.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lund, J.W.
1995-12-31
Onion dehydration consists of a continuous operation, belt conveyor using fairly low-temperature hot air from 38-104{degrees}C (100 to 200{degrees}F). Typical processing plants will handle 4500 kg (10,000 pounds) of raw product per hour (single line), reducing the moisture from around 83 % to 4 % (680 to 820 kg - 1,500 to 1,800 pounds finished product). An example of a geothermal processing plant is Integrate Ingredients at Empire, Nevada, in the San Emidio Desert. A total of 6.3 million kg (14 million pounds) of dry product are produced annually: 60% onion and 40% garlic. A 130{degrees}C (266{degrees}F) well provide themore » necessary heat for the plant.« less
Radiological effluents released and public doses from nuclear power plants in Korea.
Son, Jung Kwon; Kim, Hee Geun; Kong, Tae Young; Ko, Jong Hyun; Lee, Goung Jin
2013-08-01
As of the end of 2010, there were 20 commercially operating nuclear reactors in Korea. Releases of radioactive effluents from nuclear power plants (NPPs) have increased continuously; the total radioactivity of effluent amount released in 2010 was 547.12 TBq. From 2001 to 2010, the annual average radioactivity of gaseous and liquid effluents per reactor was 11.61 TBq for pressurised water reactors and 118.12 TBq for pressurised heavy water reactors. Most of the radioactivity from gaseous and liquid effluents came from tritium. Based on the results of release trends and analyses, the characteristics of effluents have been investigated to improve the management of radioactive effluents from NPPs.
Danz, Mari E.; Corsi, Steven R.; Graczyk, David J.; Bannerman, Roger T.
2010-01-01
Knowledge of the daily, monthly, and yearly distribution of contaminant loadings and streamflow can be critical for the successful implementation and evaluation of water-quality management practices. Loading data for solids (suspended sediment and total suspended solids) and total phosphorus and streamflow data for 23 watersheds were summarized for four ecoregions of Wisconsin: the Driftless Area Ecoregion, the Northern Lakes and Forests Ecoregion, the North Central Hardwoods Ecoregion, and the Southeastern Wisconsin Till Plains Ecoregion. The Northern Lakes and Forests and the North Central Hardwoods Ecoregions were combined into one region for analysis due to a lack of sufficient data in each region. Urban watersheds, all located in the Southeastern Wisconsin Till Plains, were analyzed separately from rural watersheds as the Rural Southeastern Wisconsin Till Plains region and the Urban Southeastern Wisconsin Till Plains region. Results provide information on the distribution of loadings and streamflow between base flow and stormflow, the timing of loadings and streamflow throughout the year, and information regarding the number of days in which the majority of the annual loading is transported. The average contribution to annual solids loading from stormflow periods for the Driftless Area Ecoregion was 84 percent, the Northern Lakes and Forests/North Central Hardwoods region was 71 percent, the Rural Southeastern Wisconsin Till Plains region was 70 percent, and the Urban Southeastern Wisconsin Till Plains region was 90 percent. The average contributions to annual total phosphorus loading from stormflow periods were 72, 49, 61, and 76 percent for each of the respective regions. The average contributions to annual streamflow from stormflow periods are 20, 23, 31, and 50 percent for each of the respective regions. In all regions, the most substantial loading contributions for solids were in the late winter (February through March), spring (April through May), and early summer (June through July), with fall (October through November) and early winter (December through January) contributing the smallest loadings. The Northern Lakes and Forests/North Central Hardwoods region had some substantial loading in September. There was a similar pattern for total phosphorus loading in all regions, with the pattern somewhat less pronounced in urban watersheds. As with the loading results, average monthly streamflow values were greatest in late winter, spring, and early summer, with the lowest values typically in fall and early winter. Loading contributions were greater from stormflow than from base flow in all instances, except total phosphorus in the Northern Lakes and Forests/North Central Hardwoods region, which had equal or greater base-flow contribution for several months. Base flow constituted a greater percentage of the total streamflow than stormflow in all rural watersheds for all regions. Only a few storms each year dominated the annual loading totals for solids and total phosphorus. When daily loading values were ranked for the year, all regions reached 50 percent of the annual solids loading in the 5 highest loading days and nearly 50 percent of the annual total phosphorus loading in the 14 highest loading days.
Petry, Karl Ulrich; Barth, Cordula; Wasem, Jürgen; Neumann, Anja
2017-05-01
We modelled human papilloma virus (HPV) primary screening scenarios compared with Pap cytology to evaluate clinical effectiveness and projected annual costs in Germany. A Markov cohort model was built to compare the budget impact of annual Pap cytology with different 5-yearly HPV screening scenarios: (1) a positive HPV test followed by Pap cytology; (2) a positive HPV test followed by p16/Ki-67 dual-stained cytology; (3) a positive HPV test followed by colposcopy if HPV-16/18-positive or p16/Ki-67 dual-stained cytology if positive for other subtypes; (4) co-testing with HPV and Pap. Screening scenarios were based on a 10-year horizon. All HPV screening scenarios in the model were associated with fewer deaths from missed diagnosis of cervical cancer compared with Pap screening; 10-year totals n=172-344 (1.5-3 per 100,000) versus n=477 (4.1 per 100,000), respectively. Total annual costs were lower with HPV screening than Pap cytology. The projected average annual cost for HPV screening ranged from €117 million to €136 million compared with €177 million for Pap screening, representing annual savings of €41-60 million. The greatest clinical impact was achieved with primary HPV screening (with genotyping) followed by colposcopy for HPV 16/18-positive women or p16/Ki-67 dual-stained cytology for women positive for other HPV subtypes. Screening strategies including primary HPV testing for high-risk subtypes (HPV-16/18) in conjunction with p16/Ki-67 dual-stained cytology can improve the detection of cervical cancer at a lower total annual cost than conventional Pap cytology screening. Copyright © 2017. Published by Elsevier B.V.
Powers, Stephen M.; Robertson, Dale M.; Stanley, Emily H.
2014-01-01
Recently, effects of lakes and reservoirs on river nutrient export have been incorporated into landscape biogeochemical models. Because annual export varies with precipitation, there is a need to examine the biogeochemical role of lakes and reservoirs over time frames that incorporate interannual variability in precipitation. We examined long-term (~20 years) time series of river export (annual mass yield, Y, and flow-weighted mean annual concentration, C) for total nitrogen (TN), total phosphorus (TP), and total suspended sediment (TSS) from 54 catchments in Wisconsin, USA. Catchments were classified as small agricultural, large agricultural, and forested by use of a cluster analysis, and these varied in lentic coverage (percentage of catchment lake or reservoir water that was connected to river network). Mean annual export and interannual variability (CV) of export (for both Y and C) were higher in agricultural catchments relative to forested catchments for TP, TN, and TSS. In both agricultural and forested settings, mean and maximum annual TN yields were lower in the presence of lakes and reservoirs, suggesting lentic denitrification or N burial. There was also evidence of long-term lentic TP and TSS retention, especially when viewed in terms of maximum annual yield, suggesting sedimentation during high loading years. Lentic catchments had lower interannual variability in export. For TP and TSS, interannual variability in mass yield was often >50% higher than interannual variability in water yield, whereas TN variability more closely followed water (discharge) variability. Our results indicate that long-term mass export through rivers depends on interacting terrestrial, aquatic, and meteorological factors in which the presence of lakes and reservoirs can reduce the magnitude of export, stabilize interannual variability in export, as well as introduce export time lags.
Operations Analysis of the 2nd Generation Reusable Launch Vehicle
NASA Technical Reports Server (NTRS)
Noneman, Steven R.; Smith, C. A. (Technical Monitor)
2002-01-01
The Space Launch Initiative (SLI) program is developing a second-generation reusable launch vehicle. The program goals include lowering the risk of loss of crew to 1 in 10,000 and reducing annual operations cost to one third of the cost of the Space Shuttle. The SLI missions include NASA, military and commercial satellite launches and crew and cargo launches to the space station. The SLI operations analyses provide an assessment of the operational support and infrastructure needed to operate candidate system architectures. Measures of the operability are estimated (i.e. system dependability, responsiveness, and efficiency). Operations analysis is used to determine the impact of specific technologies on operations. A conceptual path to reducing annual operations costs by two thirds is based on key design characteristics, such as reusability, and improved processes lowering labor costs. New operations risks can be expected to emerge. They can be mitigated with effective risk management with careful identification, assignment, tracking, and closure. SLI design characteristics such as nearly full reusability, high reliability, advanced automation, and lowered maintenance and servicing coupled with improved processes are contributors to operability and large operating cost reductions.
76 FR 66741 - Agency Information Collection Activities: Prior Disclosure
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-27
... forms of information technology; and (e) the annual cost burden to respondents or record keepers from... Responses: 3,500. Estimated Time per Response: 1 hour. Estimated Total Annual Burden Hours: 3,500. Dated...
ERIC Educational Resources Information Center
Reda, Mario R.
The purpose of this paper is the presentation of a proposal for a year-round operation and an annual assignment system (YRO/AAS) to the administrative officers of the College of DuPage, Glen Ellyn, Illinois. The proposal is comprised of four chapters. The first chapter deals with the significance of the study in terms of the College of DuPage's…
Comparison of alternative flue gas dry treatment technologies in waste-to-energy processes.
Dal Pozzo, Alessandro; Antonioni, Giacomo; Guglielmi, Daniele; Stramigioli, Carlo; Cozzani, Valerio
2016-05-01
Acid gases such as HCl and SO2 are harmful both for human health and ecosystem integrity, hence their removal is a key step of the flue gas treatment of Waste-to-Energy (WtE) plants. Methods based on the injection of dry sorbents are among the Best Available Techniques for acid gas removal. In particular, systems based on double reaction and filtration stages represent nowadays an effective technology for emission control. The aim of the present study is the simulation of a reference two-stage (2S) dry treatment system performance and its comparison to three benchmarking alternatives based on single stage sodium bicarbonate injection. A modelling procedure was applied in order to identify the optimal operating configuration of the 2S system for different reference waste compositions, and to determine the total annual cost of operation. Taking into account both operating and capital costs, the 2S system appears the most cost-effective solution for medium to high chlorine content wastes. A Monte Carlo sensitivity analysis was carried out to assess the robustness of the results. Copyright © 2016. Published by Elsevier Ltd.
Potential Operating Room Fire Hazard of Bone Cement.
Sibia, Udai S; Connors, Kevin; Dyckman, Sarah; Zahiri, Hamid R; George, Ivan; Park, Adrian E; MacDonald, James H
Approximately 600 cases of operating room (OR) fires are reported annually. Despite extensive fire safety education and training, complete elimination of OR fires still has not been achieved. Each fire requires an ignition source, a fuel source, and an oxidizer. In this case report, we describe the potential fire hazard of bone cement in the OR. A total knee arthroplasty was performed with a standard medial parapatellar arthrotomy. Tourniquet control was used. After bone cement was applied to the prepared tibial surface, the surgeon used an electrocautery device to resect residual lateral meniscus tissue-and started a fire in the operative field. The surgeon suffocated the fire with a dry towel and prevented injury to the patient. We performed a PubMed search with a cross-reference search for relevant papers and found no case reports outlining bone cement as a potential fire hazard in the OR. To our knowledge, this is the first case report identifying bone cement as a fire hazard. OR fires related to bone cement can be eliminated by correctly assessing the setting time of the cement and avoiding application sites during electrocautery.
NASA Astrophysics Data System (ADS)
Yaghmaei, Hiva; Sadeghi, Seyed Hamidreza; Moradi, Hamidreza; Gholamalifard, Mehdi
2018-02-01
Trends in flow discharge, temperature and rainfall from the Qom Rood Watershed, Iran, for a period of 1979-2016 were analyzed at monthly and annual time scales. Trend analyses were conducted using the Mann-Kendall test, the double-mass curve of mean annual discharge versus rainfall, and rainfall-runoff relationship before and after the 15 Khordad Dam operation. Multiple regression of flow discharge against rainfall and temperature was used to determine the residual trend at four meteorological and hydrological stations located upstream and downstream of the Qom Rood Watershed. Results showed that the temperature at the upstream and downstream stations did not have any significant trend, but a significant decreasing trend (P < .05) in rainfall was detected only in May (z = -1.66) at the downstream stations. There was a significant positive trend (P < .05) in rainfall in February (z = 2.22) and July (z = 2.15) at the upstream stations, and in October (z = 2.3) and November (z = 1.8) at the downstream stations. However, there was a noticeable decrease in monthly and annual flow discharge, and residual trend at 99% significance level at the downstream stations. At the upstream stations, the flow discharges had significant (P < .05) declining trend in all months, but annual flow discharge did not change significantly. Analysis of double mass curve between runoff and rainfall at the downstream stations showed an inconsistency in the line slope concordant with the time of 15 Khordad Dam operation. Annual mean discharge at the upstream stations did not show a significant change before and after 15 Khordad Dam operation. However, annual flow magnitude decreased significantly by 87.5 and 81.7% in Shad Abad and KoohSefid, respectively. These results confirmed that natural driving forces did not affect flow discharge changes and the observed decreasing tendency in flow discharge at the downstream stations was due to 15 Khordad Dam, and at the upstream stations due to diversion/storage dams. These findings highlighted the role of human interference in changing the hydrologic regime in the study area based on which appropriate adaptive decisions can be made.
Juracek, Kyle E.
2004-01-01
Many municipalities in Kansas rely on small reservoirs as a source of drinking water and for recreational activities. Because of their significance to the community, management of the reservoirs and the associated basins is important to protect the reservoirs from degradation. Effective reservoir management requires information about water quality, sedimentation, and sediment quality. A combination of bathymetric surveying and bottom-sediment coring during 2002 and 2003 was used to investigate sediment deposition and the occurrence of selected nutrients (total nitrogen and total phosphorus), organic and total carbon, 26 trace elements, 15 organochlorine compounds, and 1 radionuclide in the bottom sediment of 10 small reservoirs in eastern Kansas. Original reservoir water-storage capacities ranged from 23 to 5,845 acre-feet. The mostly agricultural reservoir basins range in area from 0.6 to 14 square miles. The mean annual net volume of deposited sediment, estimated separately for several of the reservoirs, ranged from about 43,600 to about 531,000 cubic feet. The estimated mean annual net mass of deposited sediment ranged from about 1,360,000 to about 23,300,000 pounds. The estimated mean annual net sediment yields from the reservoir basins ranged from about 964,000 to about 2,710,000 pounds per square mile. Compared to sediment yield estimates provided by a statewide study published in 1965, the estimates determined in this study differed substantially and were typically smaller. A statistically significant positive correlation was determined for the relation between sediment yield and mean annual precipitation. Nutrient concentrations in the bottom sediment varied substantially among the 10 reservoirs. Median total nitrogen concentrations ranged from 1,400 to 3,700 milligrams per kilogram. Median total phosphorus concentrations ranged from 550 to 1,300 milligrams per kilogram. A statistically significant positive trend (that is, nutrient concentration increased toward the top of the sediment core) was indicated in one reservoir for total nitrogen and in two reservoirs for total phosphorus. Also, a possible positive trend for total nitrogen was indicated in two other reservoirs. These trends in nutrient concentrations may be related to a statewide increase in fertilizer use. Alternatively, the trends may be indicative of diagenesis (that is, postdepositional changes in the sediment caused by various processes including decomposition). Nutrient loads and yields also varied substantially among the five reservoirs for which loads and yields were estimated. Estimated mean annual net loads of total nitrogen deposited in the bottom sediment ranged from 4,080 to 49,100 pounds. Estimated mean annual net loads of total phosphorus deposited in the bottom sediment ranged from 1,120 to 20,800 pounds. Estimated mean annual net yields of total nitrogen from the basins ranged from 2,210 to 6,800 pounds per square mile. Estimated mean annual net yields of total phosphorus from the basins ranged from 598 to 2,420 pounds per square mile. Compared to nonenforceable sediment-quality guidelines adopted by the U.S. Environmental Protection Agency, bottom-sediment concentrations of arsenic, chromium, copper, and nickel in samples from all 10 reservoirs typically exceeded the threshold-effects levels (TELs) but were less than the probable-effects levels (PELs). TELs represent the concentrations above which toxic biological effects occasionally occur in aquatic organisms, whereas PELs represent the concentrations above which toxic biological effects usually or frequently occur. Concentrations of cadmium, lead, and zinc exceeded the TELs but were less than the PELs in sediment samples from about one-half of the reservoirs and were less than the TELs in samples from the remaining reservoirs. Mercury concentrations were less than the TEL (information only available for four reservoirs). Silver was not detected in the bottom sediment fro
NASA Astrophysics Data System (ADS)
Chung, Jong-Kyun; Jee, Geonhwa; Lee, Chi-Na
2011-12-01
The total electron content (TEC) using global positioning system (GPS) is analyzed to see the characteristics of ionosphere over King Sejong station (KSJ, geographic latitude 62°13' S, longitude 58° 47' W, corrected geomagnetic latitude 48° S) in Antarctic. The GPS operational ratio during the observational period between 2005 and 2009 is 90.1%. The annual variation of the daily mean TEC decreases from January 2005 to February 2009, but increase from the June 2009. In summer (December-February), the seasonal mean TEC values have the maximum of 26.2 ± 2.4 TEC unit (TECU) in 2005 and the minimum of 16.5 ± 2.8 TECU in 2009, and the annual differences decrease from 3.0 TECU (2005-2006) to 1.4 TECU (2008-2009). However, on November 2010, it significantly increases to 22.3 ± 2.8 TECU which is up to 5.8 TECU compared with 2009 in summer. In winter (June-August), the seasonal mean TEC slightly decreases from 13.7 ± 4.5 TECU in 2005 to 8.9 ± 0.6 TECU in 2008, and the a! nnual difference is constantly about 1.6 TECU, and increases to 10.3 ± 1.8 TECU in 2009. The annual variations of diurnal amplitude show the seasonal features that are scattered in summer and the enhancements near equinoxes are apparent in the whole years. In contrast, the semidiurnal amplitudes show the disturbed annual peaks in winter and its enhancements near equinoxes are unapparent. The diurnal phases are not constant in winter and show near 12 local time (LT). The semidiurnal phases have a seasonal pattern between 00 LT and 06 LT. Consequently, the KSJ GPS TEC variations show the significant semidiurnal variation in summer from December to February under the solar minimum between 2005 and 2009. The feature is considered as the Weddell Sea anomaly of larger nighttime electron density than a daytime electron density that has been observed around the Antarctica peninsula.
Li, Hao; Dong, Siping; Liu, Tingfang
2014-04-06
Third-grade hospitals in Beijing have been rapidly developing in capacity and scale for many years. These hospitals receive a large number of patients, and ensuring their efficient operation is crucial in meeting people's healthcare needs. In this context, a study of their relative efficiency and productivity would be helpful to identify the driving factors and further improve their performance. After a review of literature, the current numbers of open beds and employees were selected as input variables. The number of outpatient and emergency visits and the number of discharged patients were selected as output variables. A total of 12 third-grade Class A general public hospitals in Beijing were selected for a preliminary study. The panel data from 2006-2009 were collected by the National Institute of Hospital Administration, Ministry of Health of P.R. China. Descriptive analysis and data envelopment analysis were used to analyze the data using Stata 10.0 and DEAP(V2.1) software. In the 2006-2009 period, descriptive results show that sample hospitals continuously expanded their capacity and scale, with growth rate of total revenue being the highest among all variables. The DEA results show that the average annual growth rate of productivity was 26.7%, and the rates were 47.3%, 21.3% and 13.8% respectively for two consecutive years. The average annual growth rate of technological change was 28.3%, and the rates were 49.4%, 21.5% and 16.4% respectively for two consecutive years. The average annual growth rate of technical efficiency change was -1.3%, and the rates were -1.4%, -0.02% and -2.2% respectively for two consecutive years. The sample hospitals in Beijing experienced substantial productivity growth, but annual growth rates were declining. Substantial technological change was the main contributor to the growth. Although some hospitals exhibited improvements in technical efficiency, there was a slight decline in general. To improve overall efficiency and productivity, both government and hospitals need to further drive positive technological change, technical change, and allocative efficiency of public hospitals. More empirical studies are needed to include more hospitals of all three grades at a larger scale.
Evaluating cell phone data for AADT estimation : research project capsule.
DOT National Transportation Integrated Search
2016-04-01
Annual average daily traffic (AADT) is a key input in a transportation agencys roadway : planning, design, operation, and maintenance activities, including air quality and : safety assessments. AADT is required to be reported annually by a state...
Estimation of annual average daily traffic for off-system roads in Florida
DOT National Transportation Integrated Search
1999-07-28
Estimation of Annual Average Daily Traffic (AADT) is extremely important in traffic planning and operations for the state departments of transportation (DOTs), because AADT provides information for the planning of new road construction, determination...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-28
... annual PPD Beach2Battleship iron and half iron distance triathlons. This deviation allows both... accommodate the 6th annual PPD Beach2Battleship iron and half iron distance triathlons on Saturday, October 26...
Statistic analysis of annual total ozone extremes for the period 1964-1988
NASA Technical Reports Server (NTRS)
Krzyscin, Janusz W.
1994-01-01
Annual extremes of total column amount of ozone (in the period 1964-1988) from a network of 29 Dobson stations have been examined using the extreme value analysis. The extremes have been calculated as the highest deviation of daily mean total ozone from its long-term monthly mean, normalized by the monthly standard deviations. The extremes have been selected from the direct-Sun total ozone observations only. The extremes resulting from abrupt changes in ozone (day to day changes greater than 20 percent) have not been considered. The ordered extremes (maxima in ascending way, minima in descending way) have been fitted to one of three forms of the Fisher-Tippet extreme value distribution by the nonlinear least square method (Levenberg-Marguard method). We have found that the ordered extremes from a majority of Dobson stations lie close to Fisher-Tippet type III. The extreme value analysis of the composite annual extremes (combined from averages of the annual extremes selected at individual stations) has shown that the composite maxima are fitted by the Fisher-Tippet type III and the composite minima by the Fisher-Tippet type I. The difference between the Fisher-Tippet types of the composite extremes seems to be related to the ozone downward trend. Extreme value prognoses for the period 1964-2014 (derived from the data taken at: all analyzed stations, the North American, and the European stations) have revealed that the prognostic extremes are close to the largest annual extremes in the period 1964-1988 and there are only small regional differences in the prognoses.
Climate Change and Tropical Total Lightning
NASA Technical Reports Server (NTRS)
Albrecht, R.; Petersen, W.; Buechler, D.; Goodman, S.; Blakeslee, R.; Christian, H.
2009-01-01
While global warming is regarded as a fact by many in the scientific community, its future impact remains a challenge to be determined and measured. The International Panel on Climate Change (IPCC) assessment report (IPCC, 2007) shows inconclusive answers on global rainfall trends and general agreement on a future drier climate with increased global warming. The relationship between temperature, humidity and convection is not linear and is strongly dependent on regional scale features, such as topography and land cover. Furthermore, the relationship between convective lightning production (thunderstorms) and temperature is even more complicated, being subjected to the cloud dynamics and microphysics. Total lightning (intracloud and cloud-to-ground) monitoring is a relatively new field of observation. Global and tropical total lightning began to be more extensively measured by satellites in the mid 90s. In this scope, the Lightning Imaging Sensor (LIS) onboard of the Tropical Rainfall Measurement Mission (TRMM) has been operational for over 11 years. Here we address total lightning trends observed by LIS from 1998 to 2008 in different temporal (annual and seasonal) and spatial (large and regional) scales. The observed 11-year trends are then associate to different predicted/hypothesized climate change scenarios.
On the Analysis of the Climatology of Cloudiness of the Arabian Peninsula
NASA Astrophysics Data System (ADS)
Yousef, L. A.; Temimi, M.
2015-12-01
This study aims to determine the climatology of cloudiness over the Arabian Peninsula. The determined climatology will assist solar energy resource assessment in the region. The seasonality of cloudiness and its spatial variability will also help guide several cloud seeding operational experiments in the region. Cloud properties from the International Satellite Cloud Climatology Project (ISCCP) database covering the time period from 1983 through 2009 are analyzed. Time series of low, medium, high, and total cloud amounts are investigated, in addition to cloud optical depth and total column water vapor. Initial results show significant decreasing trends in the total and middle cloud amounts, both annually and seasonally, at a 95% confidence interval. The relationship between cloud amounts and climate oscillations known to affect the region is explored. Climate indices exhibiting significant correlations with the total cloud amounts include the Pacific Decadal Oscillation (PDO) index. The study also includes a focus on the United Arab Emirates (UAE), comparing the inferred cloudiness data to in situ rainfall measurements taken from rain gauges across the UAE. To assess the impact of cloudiness on solar power resources in the country, time series of cloud amounts and Direct Normal Irradiance (DNI), obtained from the UAE Solar Atlas, are compared.
Taylor, Colman B; Stevenson, Mark; Jan, Stephen; Liu, Bette; Tall, Gary; Middleton, Paul M; Fitzharris, Michael; Myburgh, John
2011-10-01
Helicopter Emergency Medical Services (HEMS) have been incorporated into modern health systems for their speed and coverage. In the state of New South Wales (NSW), nine HEMS operate from various locations around the state and currently there is no clear picture of their resource implications. The aim of this study was to assess the cost of HEMS in NSW and investigate the factors linked with the variation in the costs, coverage and activities of HEMS. We undertook a survey of HEMS costs, structures and operations in NSW for the 2008/2009 financial year. Costs were estimated from annual reports and contractual agreements. Data related to the structure and operation of services was obtained by face-to-face interviews, from operational data extracted from individual HEMS, from the NSW Ambulance Computer Aided Despatch system and from the Aeromedical Operations Centre database. In order to estimate population coverage for each HEMS, we used GIS mapping techniques with Australian Bureau of Statistics census information. Across HEMS, cost per mission estimates ranged between $9300 and $19,000 and cost per engine hour estimates ranged between $5343 and $15,743. Regarding structural aspects, six HEMS were run by charities or not-for-profit companies (with partial government funding) and three HEMS were run (and fully funded) by the state government through NSW Ambulance. Two HEMS operated as 'hub' services in conjunction with three associated 'satellite' services and in contrast, four services operated independently. Variation also existed between the HEMS in the type of helicopter used, the clinical staffing and the hours of operation. The majority of services undertook both primary scene responses and secondary inter-facility transfers, although the proportion of each type of transport contributing to total operations varied across the services. This investigation highlighted the cost of HEMS operations in NSW which in total equated to over $50 million per annum. Across services, we found large variation in the cost estimates which was underscored by variation in the structure and operations of HEMS. Copyright © 2011 Elsevier Ltd. All rights reserved.