Effect of stride length on overarm throwing delivery: A linear momentum response.
Ramsey, Dan K; Crotin, Ryan L; White, Scott
2014-12-01
Changing stride length during overhand throwing delivery is thought to alter total body and throwing arm linear momentums, thereby altering the proportion of throwing arm momentum relative to the total body. Using a randomized cross-over design, nineteen pitchers (15 collegiate and 4 high school) were assigned to pitch two simulated 80-pitch games at ±25% of their desired stride length. An 8-camera motion capture system (240Hz) integrated with two force plates (960Hz) and radar gun tracked each throw. Segmental linear momentums in each plane of motion were summed yielding throwing arm and total body momentums, from which compensation ratio's (relative contribution between the two) were derived. Pairwise comparisons at hallmark events and phases identified significantly different linear momentum profiles, in particular, anteriorly directed total body, throwing arm, and momentum compensation ratios (P⩽.05) as a result of manipulating stride length. Pitchers with shorter strides generated lower forward (anterior) momentum before stride foot contact, whereas greater upward and lateral momentum (toward third base) were evident during the acceleration phase. The evidence suggests insufficient total body momentum in the intended throwing direction may potentially influence performance (velocity and accuracy) and perhaps precipitate throwing arm injuries. Copyright © 2014 Elsevier B.V. All rights reserved.
Research on characteristics of symmetric optothermal microactuators.
Wang, Y D; You, Q Y; Chen, J J; Zhang, H J
2018-04-01
This paper proposes and studies symmetric optothermal microactuators (OTMAs) which are directly controlled by a laser beam. Based on the principle of thermal flux, a theoretical model is established to describe the laser-induced temperature rises and optothermal expansions of the OTMAs' expansion arms. Temperature rise distributions of the arms with lengths of 590, 990, and 2260 μm are simulated separately, which reveals that, under 2 mW laser irradiation, the maximum temperature rises are invariably less than 75.9°C. Simulations are also made to consider optothermal expansions of the arms caused by laser irradiation, which turns out that expansion increases considerably when the arm's length increases from 250 to 1000 μm, while insignificantly between 1250 and 2500 μm. Under a laser beam of 2 mW power, experiments on three microfabricated OTMAs have been further conducted, which demonstrate that the OTMAs are capable of generating maximum deflections of 7.3, 11.3, and 13.6 μm, and that the growth of deflection is comparatively obvious in the case when the total length changes from 750 to 1200 μm, while insignificant for the range between 1200 and 2380 μm. With regard to simulations and experiments, it has been proved that the OTMAs are capable of implementing direct laser-controlled microactuation in which only about 2 mW laser power is demanded. Moreover, it has been proved that twofold total length or arm length does not correspondingly result in doubling the deflection, nor the expansion. Therefore, total length/expansion arm's length around or less than 1200/1000 μm is more appropriate for obtaining satisfactory characteristics of OTMAs, which may be potentially applied in MEMS/MOEMS and micro-/nano-technology.
Allometric associations between body size, shape, and 100-m butterfly speed performance.
Sammoud, Senda; Nevill, Alan M; Negra, Yassine; Bouguezzi, Raja; Chaabene, Helmi; Hachana, Younés
2018-05-01
This study aimed to estimate the optimal body size, limb-segment length, and girth or breadth ratios associated with 100-m butterfly speed performance in swimmers. One-hundred-sixty-seven swimmers as subjects (male: N.=103; female: N.=64). Anthropometric measurements comprised height, body-mass, skinfolds, arm-span, upper-limb-length, upper-arm, forearm, hand-lengths, lower-limb-length, thigh-length, leg-length, foot-length, arm-relaxed-girth, forearm-girth, wrist-girth, thigh-girth, calf-girth, ankle-girth, biacromial and biiliocristal-breadths. To estimate the optimal body size and body composition components associated with 100-m butterfly speed performance, we adopted a multiplicative allometric log-linear regression model, which was refined using backward elimination. Fat-mass was the singularly most important whole-body characteristic. Height and body-mass did not contribute to the model. The allometric model identified that having greater limb segment length-ratio (arm-ratio = [arm-span]/[forearm]) and limb girth-ratio (girth-ratio = [calf-girth]/[ankle-girth]) were key to butterfly speed performance. A greater arm-span to forearm-length ratio and a greater calf to ankle-girth-ratio suggest that a combination of larger arm-span and shorter forearm-length and the combination of larger calves and smaller ankles-girth may benefit butterfly swim speed performance. In addition having greater biacromial and biliocristal breadths is also a major advantage in butterfly swimming speed performance. Finally, the estimation of these ratios was made possible by adopting a multiplicative allometric model that was able to confirm, theoretically, that swim speeds are nearly independent of total body size. The 100-m butterfly speed performance was strongly negatively associated with fat mass and positively associated with the segment length ratio (arm-span/forearm-length) and girth ratio (calf-girth)/(ankle-girth), having controlled for the developmental changes in age.
Impact of direct substitution of arm span length for current standing height in elderly COPD.
Pothirat, Chaicharn; Chaiwong, Warawut; Phetsuk, Nittaya
2015-01-01
Arm span length is related to standing height and has been studied as a substitute for current standing height for predicting lung function parameters. However, it has never been studied in elderly COPD patients. To evaluate the accuracy of substituting arm span length for current standing height in the evaluation of pulmonary function parameters and severity classification in elderly Thai COPD patients. Current standing height and arm span length were measured in COPD patients aged >60 years. Postbronchodilator spirometric parameters, forced vital capacity (FVC), forced expiratory volume in first second (FEV1), and ratio of FEV1/FVC (FEV1%), were used to classify disease severity according to global initiative for chronic obstructive lung disease criteria. Predicted values for each parameter were also calculated separately utilizing current standing height or arm span length measurements. Student's t-tests and chi-squared tests were used to compare differences between the groups. Statistical significance was set at P<0.05. A total of 106 COPD patients with a mean age of 72.1±7.8 years, mean body mass index of 20.6±3.8 kg/m(2), and mean standing height of 156.4±8.3 cm were enrolled. The mean arm span length exceeded mean standing height by 7.7±4.6 cm (164.0±9.0 vs 156.4±8.3 cm, P<0.001), at a ratio of 1.05±0.03. Percentages of both predicted FVC and FEV1 values based on arm span length were significantly lower than those using current standing height (76.6±25.4 vs 61.6±16.8, P<0.001 and 50.8±25.4 vs 41.1±15.3, P<0.001). Disease severity increased in 39.6% (42/106) of subjects using arm span length over current standing height for predicted lung function. Direct substitution of arm span length for current standing height in elderly Thai COPD patients should not be recommended in cases where arm span length exceeds standing height by more than 4 cm.
Escovar, Jesús; Ferro, Cristina; Cárdenas, Estrella; Bello, Felio
2002-12-01
Cytogenetic characteristics were established for five native species of phlebotomine sand flies (Lutzomyia, series townsendi, verrucarum group): Lutzomyia longiflocosa, Lutzomyia townsendi, Lutzomyia spinicrassa, Lutzomyia torvida and Lutzomyia youngi. Karyotypes and chromosomal morphometry were compared. Using the squash technique, brain tissues from late 4th instar larvae provided the necessary mitotic chromosomes. Chromosomal measurements were made on the following chromosomal characteristics: short arm, long arm, arm ratio, total length, relative length, centromeric index and relative length average of chromosomes. Chromosomes were classified according to their morphometry and position of the centromere. The taxonomic distance was calculated, and the relationships among the species displayed in a phenogram. All five species possessed four pairs of chromosomes as diploid number (2N = 8). None of the karyotypes indicated presence of heteromorphic chromosomes. Statistical analysis of the morphometric data showed highly significant differences among the chromosomes pairs of the five species. However, the total length of the genome was very similar, with the exception of L. youngi. In conclusion, these closely related species were distinguishable at cytological level.
Relationship between extrinsic factors and the acromio-humeral distance.
Mackenzie, Tanya Anne; Herrington, Lee; Funk, Lenard; Horsley, Ian; Cools, Ann
2016-06-01
Maintenance of the subacromial space is important in impingement syndromes. Research exploring the correlation between biomechanical factors and the subacromial space would be beneficial. To establish if relationship exists between the independent variables of scapular rotation, shoulder internal rotation, shoulder external rotation, total arc of shoulder rotation, pectoralis minor length, thoracic curve, and shoulder activity level with the dependant variables: AHD in neutral, AHD in 60° arm abduction, and percentage reduction in AHD. Controlled laboratory study. Data from 72 male control shoulders (24.28years STD 6.81 years) and 186 elite sportsmen's shoulders (25.19 STD 5.17 years) were included in the analysis. The independent variables were quantified and real time ultrasound was used to measure the dependant variable acromio-humeral distance. Shoulder internal rotation and pectoralis minor length, explained 8% and 6% respectively of variance in acromio-humeral distance in neutral. Pectoralis minor length accounted for 4% of variance in 60° arm abduction. Total arc of rotation, shoulder external rotation range, and shoulder activity levels explained 9%, 15%, and 16%-29% of variance respectively in percentage reduction in acromio-humeral distance during arm abduction to 60°. Pectorals minor length, shoulder rotation ranges, total arc of shoulder rotation, and shoulder activity levels were found to have weak to moderate relationships with acromio-humeral distance. Existence and strength of relationship was population specific and dependent on arm position. Relationships only accounted for small variances in AHD indicating that in addition to these factors there are other factors involved in determining AHD. Copyright © 2016 Elsevier Ltd. All rights reserved.
Code of Federal Regulations, 2014 CFR
2014-07-01
... if I do not have an arm's-length transportation contract or arm's-length tariff? 1206.111 Section... I do not have an arm's-length transportation contract or arm's-length tariff? (a) This section applies if you or your affiliate do not have an arm's-length transportation contract, including situations...
Code of Federal Regulations, 2012 CFR
2012-07-01
... if I do not have an arm's-length transportation contract or arm's-length tariff? 1206.111 Section... I do not have an arm's-length transportation contract or arm's-length tariff? (a) This section applies if you or your affiliate do not have an arm's-length transportation contract, including situations...
Code of Federal Regulations, 2013 CFR
2013-07-01
... if I do not have an arm's-length transportation contract or arm's-length tariff? 1206.111 Section... I do not have an arm's-length transportation contract or arm's-length tariff? (a) This section applies if you or your affiliate do not have an arm's-length transportation contract, including situations...
Code of Federal Regulations, 2011 CFR
2011-07-01
... if I do not have an arm's-length transportation contract or arm's-length tariff? 1206.111 Section... transportation allowance if I do not have an arm's-length transportation contract or arm's-length tariff? (a) This section applies if you or your affiliate do not have an arm's-length transportation contract...
Deurenberg, P; Deurenberg-Yap, M; Schouten, F J M
2002-03-01
To test the impact of body build factors on the validity of impedance-based body composition predictions across (ethnic) population groups and to study the suitability of segmental impedance measurements. Cross-sectional observational study. Ministry of Health and School of Physical Education, Nanyang Technological University, Singapore. A total of 291 female and male Chinese, Malays and Indian Singaporeans, aged 18-69, body mass index (BMI) 16.0-40.2 kg/ m2. Anthropometric parameters were measured in addition to impedance (100 kHz) of the total body, arms and legs. Impedance indexes were calculated as height2/impedance. Arm length (span) and leg length (sitting height), wrist and knee width were measured from which body build indices were calculated. Total body water (TBW) was measured using deuterium oxide dilution. Extra cellular water (ECW) was measured using bromide dilution. Body fat percentage was determined using a chemical four-compartment model. The bias of TBW predicted from total body impedance index (bias: measured minus predicted TBW) was different among the three ethnic groups, TBW being significantly underestimated in Indians compared to Chinese and Malays. This bias was found to be dependent on body water distribution (ECW/TBW) and parameters of body build, mainly relative (to height) arm length. After correcting for differences in body water distribution and body build parameters the differences in bias across the ethnic groups disappeared. The impedance index using total body impedance was better correlated with TBW than the impedance index of arm or leg impedance, even after corrections for body build parameters. The study shows that ethnic-specific bias of impedance-based prediction formulas for body composition is due mainly to differences in body build among the ethnic groups. This means that the use of 'general' prediction equations across different (ethnic) population groups without prior testing of their validity should be avoided. Total body impedance has higher predictive value than segmental impedance.
26 CFR 48.4216(b)-3 - Constructive sale price; special rule for arm's-length sales.
Code of Federal Regulations, 2010 CFR
2010-04-01
... volume of sales which are at retail or to retailers, or both, is less than half the total industry dollar volume of sales at all levels of distribution by manufacturers, producers, or importers, including sales... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Constructive sale price; special rule for arm's...
Axial and appendicular body proportions for evaluation of limb and trunk asymmetry.
Weinberg, Douglas S; Liu, Raymond W; Li, Samuel Q; Sanders, James O; Cooperman, Daniel R
2017-04-01
Background and purpose - When children with irregular body proportions or asymmetric limbs present, it may be unclear where the pathology is located. An improved understanding of the clinical ratio between upper extremity, lower extremity, and spine length may help elucidate whether there is disproportion between the trunk and limbs, and whether there is a reduction deficit of the shorter limb rather than hypertrophy of the longer limb. Patients and methods - We used the Brush Foundation study of child growth and development, which was a prospective, longitudinal study of healthy children between the 1930s and the 1950s, and we collected serial clinical measurements for 290 children at 3,326 visits. Children ranged from 2 to 20 years of age during the study period. Linear and quadratic regression were used to construct nomographs and 95% prediction intervals for anthropometric body proportions. Results - The maximum anterior superior iliac spine height to sitting height ratio occurred at 12.4 years in females and at 14.17 years in males. Overall, the ratio of arm length to sitting height was 0.76 (SD 0.06), the ratio of arm length to anterior superior iliac spine height was 0.76 (SD 0.03), and the ratio of anterior superior iliac spine height to sitting height was 0.98 (SD 0.13). When comparing ratios between arm length, anterior superior iliac spine height, and sitting height, the smallest variance between appendicular proportions was found in the arm length to anterior superior iliac spine height ratio. Interpretation - We recommend comparisons between total arm length and anterior superior iliac spine height to distinguish limb reduction deficits from hemi-hypertrophy, with sitting height being used only if combined upper and lower extremity discrepancy is noted.
Axial and appendicular body proportions for evaluation of limb and trunk asymmetry
Weinberg, Douglas S; Liu, Raymond W; Li, Samuel Q; Sanders, James O; Cooperman, Daniel R
2017-01-01
Background and purpose When children with irregular body proportions or asymmetric limbs present, it may be unclear where the pathology is located. An improved understanding of the clinical ratio between upper extremity, lower extremity, and spine length may help elucidate whether there is disproportion between the trunk and limbs, and whether there is a reduction deficit of the shorter limb rather than hypertrophy of the longer limb. Patients and methods We used the Brush Foundation study of child growth and development, which was a prospective, longitudinal study of healthy children between the 1930s and the 1950s, and we collected serial clinical measurements for 290 children at 3,326 visits. Children ranged from 2 to 20 years of age during the study period. Linear and quadratic regression were used to construct nomographs and 95% prediction intervals for anthropometric body proportions. Results The maximum anterior superior iliac spine height to sitting height ratio occurred at 12.4 years in females and at 14.17 years in males. Overall, the ratio of arm length to sitting height was 0.76 (SD 0.06), the ratio of arm length to anterior superior iliac spine height was 0.76 (SD 0.03), and the ratio of anterior superior iliac spine height to sitting height was 0.98 (SD 0.13). When comparing ratios between arm length, anterior superior iliac spine height, and sitting height, the smallest variance between appendicular proportions was found in the arm length to anterior superior iliac spine height ratio. Interpretation We recommend comparisons between total arm length and anterior superior iliac spine height to distinguish limb reduction deficits from hemi-hypertrophy, with sitting height being used only if combined upper and lower extremity discrepancy is noted. PMID:27998211
Code of Federal Regulations, 2013 CFR
2013-07-01
... under an arm's-length transportation contract? 1206.110 Section 1206.110 Mineral Resources OFFICE OF... Oil § 1206.110 How do I determine a transportation allowance under an arm's-length transportation contract? (a) If you or your affiliate incur transportation costs under an arm's-length transportation...
Code of Federal Regulations, 2014 CFR
2014-07-01
... under an arm's-length transportation contract? 1206.110 Section 1206.110 Mineral Resources OFFICE OF... Oil § 1206.110 How do I determine a transportation allowance under an arm's-length transportation contract? (a) If you or your affiliate incur transportation costs under an arm's-length transportation...
Code of Federal Regulations, 2012 CFR
2012-07-01
... under an arm's-length transportation contract? 1206.110 Section 1206.110 Mineral Resources OFFICE OF... Oil § 1206.110 How do I determine a transportation allowance under an arm's-length transportation contract? (a) If you or your affiliate incur transportation costs under an arm's-length transportation...
Code of Federal Regulations, 2010 CFR
2010-07-01
... under an arm's-length transportation contract? 206.110 Section 206.110 Mineral Resources MINERALS... § 206.110 How do I determine a transportation allowance under an arm's-length transportation contract? (a) If you or your affiliate incur transportation costs under an arm's-length transportation contract...
27 CFR 53.96 - Constructive sale price; special rule for arm's-length sales.
Code of Federal Regulations, 2012 CFR
2012-04-01
...; special rule for arm's-length sales. 53.96 Section 53.96 Alcohol, Tobacco Products and Firearms ALCOHOL... sale price; special rule for arm's-length sales. (a) In general. Section 4216(b)(2) of the Code... distributors in arm's-length transactions, and the manufacturer establishes that its prices in such cases are...
27 CFR 53.96 - Constructive sale price; special rule for arm's-length sales.
Code of Federal Regulations, 2011 CFR
2011-04-01
...; special rule for arm's-length sales. 53.96 Section 53.96 Alcohol, Tobacco Products and Firearms ALCOHOL... sale price; special rule for arm's-length sales. (a) In general. Section 4216(b)(2) of the Code... distributors in arm's-length transactions, and the manufacturer establishes that its prices in such cases are...
30 CFR 206.103 - How do I value oil that is not sold under an arm's-length contract?
Code of Federal Regulations, 2010 CFR
2010-07-01
... arm's-length contract? 206.103 Section 206.103 Mineral Resources MINERALS MANAGEMENT SERVICE... oil that is not sold under an arm's-length contract? This section explains how to value oil that you... average of the gross proceeds accruing to the seller under your or your affiliates' arm's-length contracts...
27 CFR 53.96 - Constructive sale price; special rule for arm's-length sales.
Code of Federal Regulations, 2013 CFR
2013-04-01
...; special rule for arm's-length sales. 53.96 Section 53.96 Alcohol, Tobacco Products and Firearms ALCOHOL... sale price; special rule for arm's-length sales. (a) In general. Section 4216(b)(2) of the Code... distributors in arm's-length transactions, and the manufacturer establishes that its prices in such cases are...
Code of Federal Regulations, 2011 CFR
2011-07-01
... under an arm's-length transportation contract? 1206.110 Section 1206.110 Mineral Resources OFFICE OF... VALUATION Federal Oil § 1206.110 How do I determine a transportation allowance under an arm's-length transportation contract? (a) If you or your affiliate incur transportation costs under an arm's-length...
27 CFR 53.96 - Constructive sale price; special rule for arm's-length sales.
Code of Federal Regulations, 2014 CFR
2014-04-01
...; special rule for arm's-length sales. 53.96 Section 53.96 Alcohol, Tobacco Products and Firearms ALCOHOL... sale price; special rule for arm's-length sales. (a) In general. Section 4216(b)(2) of the Code... distributors in arm's-length transactions, and the manufacturer establishes that its prices in such cases are...
30 CFR 1206.103 - How do I value oil that is not sold under an arm's-length contract?
Code of Federal Regulations, 2012 CFR
2012-07-01
... arm's-length contract? 1206.103 Section 1206.103 Mineral Resources OFFICE OF NATURAL RESOURCES REVENUE... oil that is not sold under an arm's-length contract? This section explains how to value oil that you...-weighted average of the gross proceeds accruing to the seller under your or your affiliates' arm's-length...
30 CFR 1206.103 - How do I value oil that is not sold under an arm's-length contract?
Code of Federal Regulations, 2013 CFR
2013-07-01
... arm's-length contract? 1206.103 Section 1206.103 Mineral Resources OFFICE OF NATURAL RESOURCES REVENUE... oil that is not sold under an arm's-length contract? This section explains how to value oil that you...-weighted average of the gross proceeds accruing to the seller under your or your affiliates' arm's-length...
30 CFR 1206.103 - How do I value oil that is not sold under an arm's-length contract?
Code of Federal Regulations, 2014 CFR
2014-07-01
... arm's-length contract? 1206.103 Section 1206.103 Mineral Resources OFFICE OF NATURAL RESOURCES REVENUE... oil that is not sold under an arm's-length contract? This section explains how to value oil that you...-weighted average of the gross proceeds accruing to the seller under your or your affiliates' arm's-length...
30 CFR 1206.103 - How do I value oil that is not sold under an arm's-length contract?
Code of Federal Regulations, 2011 CFR
2011-07-01
... arm's-length contract? 1206.103 Section 1206.103 Mineral Resources OFFICE OF SURFACE MINING... Oil § 1206.103 How do I value oil that is not sold under an arm's-length contract? This section... affiliates' arm's-length contracts for the purchase or sale of production from the field or area during the...
Forman, Michele R; Zhu, Yeyi; Hernandez, Ladia M; Himes, John H; Dong, Yongquan; Danish, Robert K; James, Kyla E; Caulfield, Laura E; Kerver, Jean M; Arab, Lenore; Voss, Paula; Hale, Daniel E; Kanafani, Nadim; Hirschfeld, Steven
2014-09-01
Surrogate measures are needed when recumbent length or height is unobtainable or unreliable. Arm span has been used as a surrogate but is not feasible in children with shoulder or arm contractures. Ulnar length is not usually impaired by joint deformities, yet its utility as a surrogate has not been adequately studied. In this cross-sectional study, we aimed to examine the accuracy and reliability of ulnar length measured by different tools as a surrogate measure of recumbent length and height. Anthropometrics [recumbent length, height, arm span, and ulnar length by caliper (ULC), ruler (ULR), and grid (ULG)] were measured in 1479 healthy infants and children aged <6 y across 8 study centers in the United States. Multivariate mixed-effects linear regression models for recumbent length and height were developed by using ulnar length and arm span as surrogate measures. The agreement between the measured length or height and the predicted values by ULC, ULR, ULG, and arm span were examined by Bland-Altman plots. All 3 measures of ulnar length and arm span were highly correlated with length and height. The degree of precision of prediction equations for length by ULC, ULR, and ULG (R(2) = 0.95, 0.95, and 0.92, respectively) was comparable with that by arm span (R(2) = 0.97) using age, sex, and ethnicity as covariates; however, height prediction by ULC (R(2) = 0.87), ULR (R(2) = 0.85), and ULG (R(2) = 0.88) was less comparable with arm span (R(2) = 0.94). Our study demonstrates that arm span and ULC, ULR, or ULG can serve as accurate and reliable surrogate measures of recumbent length and height in healthy children; however, ULC, ULR, and ULG tend to slightly overestimate length and height in young infants and children. Further testing of ulnar length as a surrogate is warranted in physically impaired or nonambulatory children. © 2014 American Society for Nutrition.
Code of Federal Regulations, 2012 CFR
2012-07-01
... or my affiliate sell(s) under an arm's-length contract? 1206.102 Section 1206.102 Mineral Resources...) under an arm's-length contract? (a) The value of oil under this section is the gross proceeds accruing to the seller under the arm's-length contract, less applicable allowances determined under § 1206.110...
Code of Federal Regulations, 2013 CFR
2013-07-01
... or my affiliate sell(s) under an arm's-length contract? 1206.102 Section 1206.102 Mineral Resources...) under an arm's-length contract? (a) The value of oil under this section is the gross proceeds accruing to the seller under the arm's-length contract, less applicable allowances determined under § 1206.110...
Code of Federal Regulations, 2014 CFR
2014-07-01
... or my affiliate sell(s) under an arm's-length contract? 1206.102 Section 1206.102 Mineral Resources...) under an arm's-length contract? (a) The value of oil under this section is the gross proceeds accruing to the seller under the arm's-length contract, less applicable allowances determined under § 1206.110...
Code of Federal Regulations, 2011 CFR
2011-07-01
... or my affiliate sell(s) under an arm's-length contract? 1206.102 Section 1206.102 Mineral Resources... affiliate sell(s) under an arm's-length contract? (a) The value of oil under this section is the gross proceeds accruing to the seller under the arm's-length contract, less applicable allowances determined...
Code of Federal Regulations, 2012 CFR
2012-07-01
... resources I sell at arm's length to a purchaser for direct use? 1206.355 Section 1206.355 Mineral Resources... arm's length to a purchaser for direct use? If you sell geothermal resources produced from Class I, II, or III leases at arm's length to a purchaser for direct use, then the royalty on the geothermal...
Code of Federal Regulations, 2013 CFR
2013-07-01
... resources I sell at arm's length to a purchaser for direct use? 1206.355 Section 1206.355 Mineral Resources... arm's length to a purchaser for direct use? If you sell geothermal resources produced from Class I, II, or III leases at arm's length to a purchaser for direct use, then the royalty on the geothermal...
Code of Federal Regulations, 2014 CFR
2014-07-01
... resources I sell at arm's length to a purchaser for direct use? 1206.355 Section 1206.355 Mineral Resources... arm's length to a purchaser for direct use? If you sell geothermal resources produced from Class I, II, or III leases at arm's length to a purchaser for direct use, then the royalty on the geothermal...
Code of Federal Regulations, 2010 CFR
2010-07-01
... resources I sell at arm's length to a purchaser for direct use? 206.355 Section 206.355 Mineral Resources... Geothermal Resources § 206.355 How do I calculate royalty due on geothermal resources I sell at arm's length... leases at arm's length to a purchaser for direct use, then the royalty on the geothermal resource is the...
30 CFR 1206.114 - What are my reporting requirements under an arm's-length transportation contract?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 3 2011-07-01 2011-07-01 false What are my reporting requirements under an arm... VALUATION Federal Oil § 1206.114 What are my reporting requirements under an arm's-length transportation... submit arm's-length transportation contracts, production agreements, operating agreements, and related...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Yan; Xu, Ye; Yang, Ji
Combining H I data from the Canadian Galactic Plane Survey and CO data from the Milky Way Imaging Scroll Painting project, we have identified a new segment of a spiral arm between Galactocentric radii of 15 and 19 kpc that apparently lies beyond the Outer Arm in the second Galactic quadrant. Over most of its length, the arm is 400-600 pc thick in z. The new arm appears to be the extension of the distant arm recently discovered by Dame and Thaddeus as well as the Scutum-Centaurus Arm into the outer second quadrant. Our current survey identified a total of 72more » molecular clouds with masses on the order of 10{sup 2}-10{sup 4} M {sub ☉} that probably lie in the new arm. When all of the available data from the CO molecular clouds are fit, the best-fitting spiral model gives a pitch angle of 9.°3 ± 0.°7.« less
Helix-coil transition of a four-way DNA junction observed by multiple fluorescence parameters.
Vámosi, György; Clegg, Robert M
2008-10-16
The thermal denaturation of immobile four-way DNA ("Holliday-") junctions with 17 base pair arms was studied via fluorescence spectroscopic measurements. Two arms of the molecule were labeled at the 5'-end with fluorescein and tetramethylrhodamine, respectively. Melting was monitored by the fluorescence intensity of the dyes, the fluorescence anisotropy of tetramethylrhodamine, and Forster resonance energy transfer (FRET) between fluorescein and rhodamine. To fit the thermal denaturation curves of the four-way junctions, two basic thermodynamic models were tested: (1) all-or-none transitions assuming a molecularity of one, two, or four and (2) a statistical "zipper" model. The all-or-none models correspond to reaction mechanisms assuming that the cooperative melting unit (that is, the structure changing from complete helix to complete coil) consists of (1) one arm, (2) two neighboring arms (which have one continuous strand common to the two arms), or (3) all four arms. In each case, the melting of the cooperative unit takes place in a single step. The tetramolecular reaction model (four-arm melting) yielded unrealistically low van't Hoff enthalpy and entropy values, whereas the monomolecular model (one-arm melting) resulted in a poor fit to the experimental data. The all-or-none bimolecular (two neighboring arm model) fit gave intermediate standard enthalpy change (Delta H) values between those expected for the melting of a duplex with a total length between the helix lengths of one and two arms (17 and 34 base pairs). Simulations according to the zipper model fit the experimental curves best when the length of the simulated duplex was assumed to be 34 base pairs, the length of a single strand. This suggests that the most important parameter determining the melting behavior of the molecule is the end-to-end distance of the strands (34 bases) rather than the length of the individual arms (17 base pairs) and that the equilibrium concentration of partially denatured intermediate states has to be taken into account. These findings are in good agreement with results obtained for three-way DNA junctions ( Stuhmeier, F. ; Lilley, D. M. ; Clegg, R. M. Biochemistry 1997, 36, 13539 ). An interesting result is that the extent-of-melting curves derived from the fluorescence intensity and anisotropy nearly agree, whereas the curve derived from the FRET data shows a change prior to the melting. This may be an indication of a conformational change leaving the double-stranded structure intact but changing the end-to-end distance of the different arms in a way consistent with the transition to the extended square configuration ( Clegg, R. M. ; Murchie, A. I. ; Lilley, D. M. Biophys. J. 1994, 66, 99 ) of this branched molecule.
Code of Federal Regulations, 2011 CFR
2011-07-01
... resources I sell at arm's length to a purchaser for direct use? 1206.355 Section 1206.355 Mineral Resources... resources I sell at arm's length to a purchaser for direct use? If you sell geothermal resources produced from Class I, II, or III leases at arm's length to a purchaser for direct use, then the royalty on the...
30 CFR 1206.114 - What are my reporting requirements under an arm's-length transportation contract?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 3 2014-07-01 2014-07-01 false What are my reporting requirements under an arm....114 What are my reporting requirements under an arm's-length transportation contract? You or your... costs you or your affiliate incur. ONRR may require you or your affiliate to submit arm's-length...
30 CFR 1206.114 - What are my reporting requirements under an arm's-length transportation contract?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 3 2013-07-01 2013-07-01 false What are my reporting requirements under an arm....114 What are my reporting requirements under an arm's-length transportation contract? You or your... costs you or your affiliate incur. ONRR may require you or your affiliate to submit arm's-length...
30 CFR 206.114 - What are my reporting requirements under an arm's-length transportation contract?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 2 2010-07-01 2010-07-01 false What are my reporting requirements under an arm... What are my reporting requirements under an arm's-length transportation contract? You or your affiliate... you or your affiliate incur. MMS may require you or your affiliate to submit arm's-length...
30 CFR 1206.114 - What are my reporting requirements under an arm's-length transportation contract?
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 3 2012-07-01 2012-07-01 false What are my reporting requirements under an arm....114 What are my reporting requirements under an arm's-length transportation contract? You or your... costs you or your affiliate incur. ONRR may require you or your affiliate to submit arm's-length...
Kruse, Christine; Rosenlund, Signe; Broeng, Leif; Overgaard, Søren
2018-01-01
The two most common surgical approaches to total hip arthroplasty are the posterior approach and lateral approach. The surgical approach may influence cup positioning and restoration of the offset, which may affect the biomechanical properties of the hip joint. The primary aim was to compare cup position between posterior approach and lateral approach. Secondary aims were to compare femoral offset, abductor moment arm and leg length discrepancy between the two approaches. Eighty patients with primary hip osteoarthritis were included in a randomized controlled trial and assigned to total hip arthroplasty using posterior approach or lateral approach. Postoperative radiographs from 38 patients in each group were included in this study for measurement of cup anteversion and inclination. Femoral offset, cup offset, total offset, abductor moment arm and leg length discrepancy were measured on preoperative and postoperative radiographs in 28 patients in each group. We found that mean anteversion was 5° larger in the posterior approach group (95% CI, -8.1 to -1.4; p = 0.006), while mean inclination was 5° less steep (95% CI, 2.7 to 7.2; p<0.001) compared with the lateral approach group. The posterior approach group had a larger mean femoral offset of 4.3mm (95% CI, -7.4 to -1.3, p = 0.006), mean total offset of 6.3mm (95% CI, -9.6 to -3; p<0.001) and mean abductor moment arm of 4.8mm (95% CI, -7.6 to -1.9; p = 0.001) compared with the lateral approach group. We found a larger cup anteversion but less steep cup inclination in the posterior approach group compared with the lateral approach group. Femoral offset and abductor moment arm were restored after total hip arthroplasty using lateral approach but significantly increased when using posterior approach.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) A return on undepreciated capital investment under paragraph (i) of this section; and (5) Once the transportation system has been depreciated below ten percent of total capital investment, a return on ten percent of total capital investment under paragraph (j) of this section. (6) To the extent not included in...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR MINERALS REVENUE MANAGEMENT PRODUCT....56 and 206.57. If the arm's-length sales contract does not reflect the total consideration actually... total consideration accruing to the seller. Use this section to value oil that: (1) You sell under an...
Three-dimensional moment arms and architecture of chimpanzee (Pan troglodytes) leg musculature
Holowka, Nicholas B; O'Neill, Matthew C
2013-01-01
The muscular and skeletal morphology of the chimpanzee ankle and foot differs from that of humans in many important respects. However, little information is available on the moment arms and architecture of the muscles that function around chimpanzee ankle and foot joints. The main goals of this study were to determine the influence of changes in leg and foot position on the moment arms of these muscle–tendon units (MTUs), and provide new measurements of their architecture. Three-dimensional moment arm data were collected from two adult, cadaveric Pan troglodytes specimens for 11 MTUs that cross the ankle and foot joints. Tendon-excursion measurements were made throughout the full range of plantarflexion–dorsiflexion (PF–DF) and eversion–inversion (EV–IN), including repeated measurements for mm. gastrocnemius at 0 °, 45 °, 90 ° and 135 ° of knee flexion. The total range of motion was calculated from three-dimensional joint motion data while ensuring that foot movement was restricted to a single plane. Measurements of muscle mass, fascicle length, pennation angle and physiological cross-sectional area were then collected for each MTU. Our results demonstrate that joint position has a significant effect on moment arm lengths, and that in some cases this effect is counterintuitive. These new data contribute to filling a significant gap in previously published chimpanzee moment arm data, providing a comprehensive characterization of the MTUs that move the chimpanzee ankle and foot joints. They also provide empirical support to the notion that chimpanzees have larger ranges of motion at these joints than humans. Comparison of osteometric estimates of moment arm lengths to direct tendon-excursion measures provides some guidance for the use of skeletal features in estimations of PF–DF moment arms. Finally, muscle architecture data are consistent with the findings of previous studies, and increase the sample size of the chimpanzee data that are currently available. PMID:24117363
Research on the measurement technology of effective arm length of swing arm profilometer
NASA Astrophysics Data System (ADS)
Chen, Lin; Jing, Hongwei; Wei, Zhongwei; Li, Jie; Cao, Xuedong
2014-09-01
When the swing arm profilometer(SAP) measuring the mirror, the effective arm length of SAP which haves an obvious influence on the measurement results of the mirror surface shape needs to be measured accurately. It requires the measurement uncertainty of the effective arm length to reach 10μm in order to meet the measurement requirements, in this paper, we present a kind of technology based on laser tracker to measure the effective arm length of SAP. When the swing arm rotates around the shaft axis of swing arm rotary stage, the probe and two laser tracker balls form three sections of circular arc around the shaft axis of swing arm rotary stage in space. Laser tracker tracks and measures the circular arcs of two laser tracker balls, the center coordinates of the circular plane of circular arc can be calculated by data processing. The linear equation that passes through the two center coordinates is the equation of the shaft axis of rotary stage, the vertical distance from the probe to the shaft axis of rotary stage which can be calculated refer to the equation from the point to the line is the effective arm length. After Matlab simulation, this measurement method can meet the measurement accuracy.
Mechanical properties of kinked silicon nanowires
NASA Astrophysics Data System (ADS)
Jing, Yuhang; Zhang, Chuan; Liu, Yingzhi; Guo, Licheng; Meng, Qingyuan
2015-04-01
Molecular dynamics simulations are used to investigate the mechanical properties of KSiNWs. Our results show that KSiNWs have a much larger fracture strain compared to straight SiNWs. The effects of the periodic length of KSiNWs with symmetric arms and the arm length of the KSiNW with asymmetric arms on the mechanical properties of KSiNWs are studied. The fracture stress of KSiNWs decrease as the periodic length increases. However, the fracture strain of KSiNWs is not dependent on the short periodic length and the fracture strain of KSiNWs will abruptly increase to very large value and then vary slightly as the periodic length increases. In addition, the fracture stress is not dependent on arm length while the fracture strain monotonically increases as the arm length increases. We also investigate the fracture process of KSiNWs. The results in this paper suggest that the KSiNWs with larger fracture strain can be a promising anode materials in high performance Li-ion batteries.
Topological analysis of long-chain branching patterns in polyolefins.
Bonchev, D; Markel, E; Dekmezian, A
2001-01-01
Patterns in molecular topology and complexity for long-chain branching are quantitatively described. The Wiener number, the topological complexity index, and a new index of 3-starness are used to quantify polymer structure. General formulas for these indices were derived for the cases of 3-arm star, H-shaped, and B-arm comb polymers. The factors affecting complexity in monodisperse polymer systems are ranked as follows: number of arms > arm length > arm central position approximately equal to arm clustering > total molecular weight approximately equal to backbone molecular weight. Topological indices change rapidly and then plateau as the molecular weight of branches on a polyolefin backbone increases from 0 to 5 kD. Complexity calculations relate 2-arm or 3-arm comb structures to the corresponding 3-arm stars of equivalent complexity but much higher molecular weight. In a subsequent paper, we report the application of topological analysis for developing structure/property relationships for monodisperse polymers. While the focus of the present work is on the description of monodisperse, well-defined architectures, the methods may be extended to the description of polydisperse systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... or my affiliate sell(s) under an arm's-length contract? 206.102 Section 206.102 Mineral Resources... Federal Oil § 206.102 How do I calculate royalty value for oil that I or my affiliate sell(s) under an arm... seller under the arm's-length contract, less applicable allowances determined under §§ 206.110 or 206.111...
NASA Astrophysics Data System (ADS)
Ciofu, C.; Stan, G.
2016-08-01
The paper emphasise positioning precision of an elephant's trunk robotic arm which has joints driven by wires with variable length while operating The considered 5 degrees of freedom robotic arm has a particular structure of joint that makes possible inner actuation with wire-driven mechanism. We analyse solely the length change of wires as a consequence due inner winding and unwinding on joints for certain values of rotational angles. Variations in wires length entail joint angular displacements. We analyse positioning precision by taking into consideration equations from inverse kinematics of the elephant's trunk robotic arm. The angular displacements of joints are considered into computational method after partial derivation of positioning equations. We obtain variations of wires length at about tenths of micrometers. These variations employ angular displacements which are about minutes of sexagesimal degree and, thus, define positioning precision of elephant's trunk robotic arms. The analytical method is used for determining aftermath design structure of an elephant's trunk robotic arm with inner actuation through wires on positioning precision. Thus, designers could take suitable decisions on accuracy specifications limits of the robotic arm.
Pellicer-Chover, Hilario; Cervera-Ballester, Juan; Peñarrocha-Oltra, David; Bagán, Leticia; Peñarrocha-Diago, María
2016-01-01
Background To assess the influence of the prosthetic arm length (palatal position) of zygomatic implants upon patient comfort and stability, speech, functionality and overall satisfaction. Material and Methods A retrospective clinical study was made of patients subjected to rehabilitation of atrophic maxilla with complete maxillary implant-supported fixed prostheses involving a minimum of two zygomatic implants (one on each side) in conjunction with premaxillary implants, and with 12 months of follow-up after implant loading. Subjects used a VAS to score general satisfaction, comfort and stability, speech and functionality, and the results were analyzed in relation to the prosthetic arm length of the zygomatic implants 12 months after prosthetic delivery. Results Twenty-two patients participated in the study, receiving 22 prostheses anchored on 148 implants (44 were zygomatic and 94 were conventional implants). The mean right and left prosthetic arm length was 5.9±2.4 mm and 6.1±2.7 mm, respectively, with no statistically significant differences between them (p=0.576). The mean scores referred to comfort/retention, speech, functionality and overall satisfaction were high - no correlation being found between prosthetic arm length and patient satisfaction (p=0.815). Conclusions No relationship could be identified between prosthetic arm length (palatal position) and patient satisfaction. Key words:Zygomatic implants, patient satisfaction, zygomatic prosthesis, prosthetic arm length. PMID:26946206
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 2 2010-07-01 2010-07-01 false What are my reporting requirements under a non-arm's-length transportation arrangement? 206.115 Section 206.115 Mineral Resources MINERALS MANAGEMENT... What are my reporting requirements under a non-arm's-length transportation arrangement? (a) You or your...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 3 2011-07-01 2011-07-01 false What are my reporting requirements under a non-arm's-length transportation arrangement? 1206.115 Section 1206.115 Mineral Resources OFFICE OF SURFACE... VALUATION Federal Oil § 1206.115 What are my reporting requirements under a non-arm's-length transportation...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 3 2013-07-01 2013-07-01 false What are my reporting requirements under a non-arm's-length transportation arrangement? 1206.115 Section 1206.115 Mineral Resources OFFICE OF NATURAL....115 What are my reporting requirements under a non-arm's-length transportation arrangement? (a) You or...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 3 2012-07-01 2012-07-01 false What are my reporting requirements under a non-arm's-length transportation arrangement? 1206.115 Section 1206.115 Mineral Resources OFFICE OF NATURAL....115 What are my reporting requirements under a non-arm's-length transportation arrangement? (a) You or...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 3 2014-07-01 2014-07-01 false What are my reporting requirements under a non-arm's-length transportation arrangement? 1206.115 Section 1206.115 Mineral Resources OFFICE OF NATURAL....115 What are my reporting requirements under a non-arm's-length transportation arrangement? (a) You or...
Butterfly Sprint Swimming Technique, Analysis of Somatic and Spatial-Temporal Coordination Variables
Stanula, Arkadiusz; Krężałek, Piotr; Ostrowski, Andrzej; Kaca, Marcin; Głąb, Grzegorz
2017-01-01
Abstract The aim of this study was to investigate somatic properties and force production of leg extensor muscles measured in the countermovement jump test (CMJ), as well as to analyse kinematic variables of sprint surface butterfly swimming. Thirty-four male competitive swimmers were recruited with an average age of 19.3 ± 1.83 years. Their average body height (BH) was 183.7 ± 5.93 cm, body fat content 10.8 ± 2.64% and body mass (BM) 78.3 ± 5.0 kg. Length measurements of particular body segments were taken and a counter movement jump (CMJ) as well as an all-out 50 m butterfly speed test were completed. The underwater movements of the swimmers’ bodies were recorded with a digital camera providing side-shots. We registered a significant relationship between body mass (r = 0.46), lean body mass (r = 0.48) and sprint surface butterfly swimming (VSBF). The anaerobic power measured in the CMJ test, total body length (TBL) as well as upper and lower extremity length indices did not influence swimming speed significantly. The temporal entry-kick index (the time ratio between the first kick and arm entry) significantly influenced VSBF (r = -0.45). Similarly, medium power of the coefficient was indicated between a) stroke rate kinematics (SR), b) duration of the first leg kick (LP1), c) air phase duration of arm recovery (Fly-arm), and VSBF (r = 0.40; r = 0.40 and r = 0.41, respectively). The entry-kick temporal index showed that, in the butterfly cycle, an appropriately early executed initial kick when compared to arm entry was associated with a longer arm propulsion phase, which in turn was associated with minimizing resistive gliding phases and enabled relatively longer and less resistive air arm recovery (higher value of the fly-arm index). The higher value of SR kinematic was another important element of the best butterfly results in this study. PMID:29339985
Berhouet, Julien; Kontaxis, Andreas; Gulotta, Lawrence V; Craig, Edward; Warren, Russel; Dines, Joshua; Dines, David
2015-04-01
Recent shoulder prostheses have introduced a concept of a universal humeral stem component platform that has an onlay humeral tray for the reverse total shoulder arthroplasty (RTSA). No studies have reported how humeral tray positioning can affect the biomechanics of RTSA. The Newcastle Shoulder Model was used to investigate the biomechanical effect of humeral tray positioning in the Biomet Comprehensive Total Shoulder System (Biomet, Warsaw, IN, USA) RTSA. Five humeral tray configuration positions were tested: no offset, and 5 mm offset in the anterior, posterior, medial, and lateral positions. Superior and inferior impingement were evaluated for abduction, scapular plane elevation, forward flexion, and external/internal rotation with the elbow at the side (adduction) and at 90° of shoulder abduction. Muscle lengths and moment arms (elevating and rotational) were calculated for the deltoid, the infraspinatus, the teres minor, and the subscapularis. Inferior impingement was not affected by the humeral tray position. There was less superior impingement during abduction, scapular plane elevation, and rotation with the shoulder when the tray was placed laterally or posteriorly. The subscapularis rotational moment arm was increased with a posterior offset, whereas infraspinatus and teres minor rotational moment arms were increased with an anterior offset. Very little change was observed for the deltoid elevating moment arm or for its muscle length. Positioning the humeral tray with posterior offset offers a biomechanical advantage for patients needing RTSA by decreasing superior impingement and increasing the internal rotational moment arm of the subscapularis, without creating inferior impingement. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-28
... orders cover all the subject bearings and parts thereof (inner race, outer race, cage, rollers, balls... producer, i.e., sales were made at arm's-length prices. See 19 CFR 351.403(c). We excluded from our... arm's-length prices. To test whether these sales were made at arm's-length prices, we compared the...
Pink, George H; Leatt, Peggy
2003-01-01
During the past decade, there has been substantial health system reform in the United States, United Kingdom, New Zealand, and many other countries. For the most part, Canada has not pursued 'big bang' health system change but rather a variety of strategies to achieve incremental change. In this paper, we present the ways in which three arms-length organizations have been used by government to effect incremental system change in Ontario during the past several years. We observe that, (1) the influence of politics and political interference can be reduced through an arms-length organization; (2) an arms-length organization with the power to make decisions entails more political risk for government and encounters more scrutiny and criticism by providers and the media than an organization with the power to recommend only; (3) an arms-length organization with a limited lifespan faces more delaying tactics by adversely affected parties than an organization without a limited lifespan; (4) an arms-length organization with perceived influence may attract causes that are not related to its mandate; (5) the importance and difficulty of communicating complex information about system change to a wide variety of audiences cannot be overstated; (6) system change informed by the use of expert opinion encounters less provider resistance and may result in better decisions; and (7) the reputation of the Chair and the perceived competence and experience of the CEO are critical success factors in the success of an arms-length organization.
26 CFR 48.4216(b)-3 - Constructive sale price; special rule for arm's-length sales.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 26 Internal Revenue 16 2011-04-01 2011-04-01 false Constructive sale price; special rule for arm's... Provisions Applicable to Manufacturers Taxes § 48.4216(b)-3 Constructive sale price; special rule for arm's... such articles to one or more wholesale distributors in arm's-length transactions, and the manufacturer...
26 CFR 48.4216(b)-3 - Constructive sale price; special rule for arm's-length sales.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 26 Internal Revenue 16 2013-04-01 2013-04-01 false Constructive sale price; special rule for arm's... Provisions Applicable to Manufacturers Taxes § 48.4216(b)-3 Constructive sale price; special rule for arm's... such articles to one or more wholesale distributors in arm's-length transactions, and the manufacturer...
26 CFR 48.4216(b)-3 - Constructive sale price; special rule for arm's-length sales.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 26 Internal Revenue 16 2012-04-01 2012-04-01 false Constructive sale price; special rule for arm's... Provisions Applicable to Manufacturers Taxes § 48.4216(b)-3 Constructive sale price; special rule for arm's... such articles to one or more wholesale distributors in arm's-length transactions, and the manufacturer...
Dissociation between running economy and running performance in elite Kenyan distance runners.
Mooses, Martin; Mooses, Kerli; Haile, Diresibachew Wondimu; Durussel, Jérôme; Kaasik, Priit; Pitsiladis, Yannis Paul
2015-01-01
The purpose of this study was to investigate the relationship between running economy (RE) and performance in a homogenous group of competitive Kenyan distance runners. Maximal aerobic capacity (VO2max) (68.8 ± 3.8 ml∙kg(-1)∙min(-1)) was determined on a motorised treadmill in 32 Kenyan (25.3 ± 5.0 years; IAAF performance score: 993 ± 77 p) distance runners. Leg anthropometry was assessed and moment arm of the Achilles tendon determined. While Achilles moment arm was associated with better RE (r(2) = 0.30, P = 0.003) and upper leg length, total leg length and total leg length to body height ratio were correlated with running performance (r = 0.42, P = 0.025; r = 0.40, P = 0.030 and r = 0.38, P = 0.043, respectively), RE and maximal time on treadmill (t(max)) were not associated with running performance (r = -0.01, P = 0.965; r = 0.27; P = 0.189, respectively) in competitive Kenyan distance runners. The dissociation between RE and running performance in this homogenous group of runners would suggest that RE can be compensated by other factors to maintain high performance levels and is in line with the idea that RE is only one of many factors explaining elite running performance.
Yoon, Jiyeon; Park, Jinse; Park, Kunbo; Jo, Geunyeol; Kim, Haeyu; Jang, Wooyoung; Kim, Ji Sun; Youn, Jinyoung; Oh, Eung Seok; Kim, Hee-Tae; Youm, Chang Hong
2016-01-01
Recently, arm facilitation has been interested in gait rehabilitation. However, there have been few studies concerning arm facilitation in patients with Parkinson's disease (PD). The aim of our study was to investigate the effect of increasing arm weights on gait pattern in patients with PD. Twenty-seven patients with PD were enrolled, and they underwent gait analysis using a three-dimensional motion capture system. Sandbags were applied to the distal forearms in all participants. We compared gait parameters including arm swing, pelvic motion, spatiotemporal data, and relative rotational angle between the weighted and unweighted gaits. The total arm-swing amplitude and pelvic rotation were significantly higher when walking with additional arm weights than without arm weights. Cadence, walking speed, stride length, and swing phase were significantly higher, whereas stride time, double-support time, and stance phase were significantly lower, when walking with additional arm weights than without arm weights. We conclude that adding weights to the arm during walking may facilitate arm and pelvic movements, which results in changes to gait patterns. The therapeutic use of additional arm weights could be considered for gait rehabilitation in PD to improve gait impairment. Arm-swing facilitation using weight load improved gait in Parkinson's disease. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
ERIC Educational Resources Information Center
Belkhir, Lotfi
2015-01-01
In this pedagogical study, we introduce the design and findings of a pilot study on the effectiveness of a new Engineering graduate course, "Total Sustainability Management", in teaching and learning sustainability, both at the cognitive and the management level. The design of an "arms-length" anonymized pre- and post-course…
Chang, Simon; Skakkebæk, Anne; Trolle, Christian; Bojesen, Anders; Hertz, Jens Michael; Cohen, Arieh; Hougaard, David Michael; Wallentin, Mikkel; Pedersen, Anders Degn; Østergaard, John Rosendahl; Gravholt, Claus Højbjerg
2015-03-01
Klinefelter syndrome, 47, XXY (KS), is underdiagnosed partly due to few clinical signs complicating identification of affected individuals. Certain phenotypic traits are common in KS. However, not all aspects of the KS phenotype are well described. To describe anthropometry and body composition in KS and relate findings to biochemistry and X-chromosome related genetic markers. Seventy three KS males referred to our clinic and 73 age-matched controls underwent comprehensive measurements of anthropometry and body composition in a cross-sectional, case-controlled study. Furthermore, genetic analysis for parental origin of the supernumerary X-chromosome, skewed X-chromosome inactivation and androgen receptor (AR) CAG repeat length was done. Anthropometry and body composition in KS and the effect of genotype hereon. KS males were taller (absolute difference: 5.1 cm, P < .001) with longer legs (5.7 cm, P < .001) compared with controls. Furthermore, 2D:4D was increased in KS males (relative effect size: Cohen's d = 0.40), reflecting reduced fetal testosterone exposure. Also, bi-iliac width (0.41), waist (0.52), and hip circumference (0.47) (P < .02 for all), as well as total fat mass (0.74), abdominal fat mass (0.67), and total body fat percentage (0.84) was increased in KS males (P < .001 for all), while bitesticular volume was reduced (4.6). AR CAG repeat length was comparable in KS and controls, and among KS CAG correlated to arm length (P = .04), arm span (P = .01), and leg length (P = .04). Effects of parental origin of the supernumerary X-chromosome and skewed X-chromosome inactivation were negligible. Anthropometry and body composition in KS is specific and dysmorphic and affected by AR CAG repeat length and decreased exposure to testosterone already during fetal life.
Code of Federal Regulations, 2011 CFR
2011-07-01
... or my affiliate sell(s) or exchange(s) under an arm's-length contract? 1206.52 Section 1206.52... my affiliate sell(s) or exchange(s) under an arm's-length contract? (a) The value of oil under this section is the gross proceeds accruing to the seller under the arm's-length contract, less applicable...
Code of Federal Regulations, 2014 CFR
2014-07-01
... or my affiliate sell(s) or exchange(s) under an arm's-length contract? 1206.52 Section 1206.52... affiliate sell(s) or exchange(s) under an arm's-length contract? (a) The value of oil under this section is the gross proceeds accruing to the seller under the arm's-length contract, less applicable allowances...
Code of Federal Regulations, 2013 CFR
2013-07-01
... or my affiliate sell(s) or exchange(s) under an arm's-length contract? 1206.52 Section 1206.52... affiliate sell(s) or exchange(s) under an arm's-length contract? (a) The value of oil under this section is the gross proceeds accruing to the seller under the arm's-length contract, less applicable allowances...
Code of Federal Regulations, 2012 CFR
2012-07-01
... or my affiliate sell(s) or exchange(s) under an arm's-length contract? 1206.52 Section 1206.52... affiliate sell(s) or exchange(s) under an arm's-length contract? (a) The value of oil under this section is the gross proceeds accruing to the seller under the arm's-length contract, less applicable allowances...
Koley, Shyamal; Pal Kaur, Satinder
2011-01-01
Purpose The purpose of this study was to estimate the dominant handgrip strength and its correlations with some hand and arm anthropometric variables in 101 randomly selected Indian inter-university female volleyball players aged 18-25 years (mean age 20.52±1.40) from six Indian universities. Methods Three anthropometric variables, i.e. height, weight, BMI, two hand anthropometric variables, viz. right and left hand width and length, four arm anthropometric variables, i.e. upper arm length, lower arm length, upper extremity length, upper arm circumference and dominant right and non-dominant handgrip strength were measured among Indian inter-university female volleyball players by standard anthropometric techniques. Results The findings of the present study indicated that Indian female volleyball players had higher mean values in eleven variables and lesser mean values in two variables than their control counterparts, showing significant differences (P<0.032-0.001) in height (t=2.63), weight (t=8.66), left hand width (t=2.10), left and right hand length (t=9.99 and 10.40 respectively), right upper arm length (t=8.48), right forearm length (t=5.41), dominant (right) and non-dominant (left) handgrip strength (t=9.37 and 6.76 respectively). In female volleyball players, dominant handgrip strength had significantly positive correlations (P=0.01) with all the variables studied. Conclusion It may be concluded that dominant handgrip strength had strong positive correlations with all the variables studied in Indian inter-university female volleyball players. PMID:22375242
Gasparini, Maurizio; Lunati, Maurizio G; Proclemer, Alessandro; Arenal, Angel; Kloppe, Axel; Martínez Ferrer, Josè B; Hersi, Ahmad S; Gulaj, Marcin; Wijffels, Maurits C E; Santi, Elisabetta; Manotta, Laura; Varma, Niraj
2017-11-01
This study sought to evaluate the effects of programming a long detection in single-chamber (VVI) implantable cardioverter-defibrillators (ICDs) in the multicenter prospective ADVANCE III (Avoid DeliVering TherApies for Non-sustained Arrhythmias in ICD PatiEnts III) trial. Programming strategies may reduce unnecessary ICD shocks and their adverse effects but to date have been described only for dual-chamber ICDs. A total of 545 subjects (85% male; atrial fibrillation 25%, left ventricular ejection fraction 31%, ischemic etiology 68%, secondary prevention indications 32%) receiving a VVI ICD were randomized to long detection (30 of 40 intervals) or standard programming (18 of 24 intervals) based on device type, atrial fibrillation history, and indication. In both arms, antitachycardia pacing (ATP) therapy during charging was programmed for episodes with cycle length 320 to 200 ms and shock only for cycle length <200 ms. Wavelet and stability functions enabled. Therapies delivered were compared using a negative binomial regression model. A total of 267 patients were randomized to long detection and 278 to the control group. Median follow-up was 12 months. One hundred twelve therapies (shocks and ATP) occurred in the long detection arm versus 257 in the control arm, for a 48% reduction with 30 of 40 intervals (95% confidence interval [CI]: 0.36 to 0.76; p = 0.002). In the long detection arm, overall shocks were reduced by 40% compared to the control arm (48 vs. 24; 95% CI: 0.38 to 0.94; p = 0.026) and appropriate shocks by 51% (34 vs. 74; 95% CI: 0.26 to 0.94; p = 0.033). Syncopal events did not differ between arms, but survival improved in the long detection arm. Among patients implanted with a VVI ICD, programming with the long detection interval significantly reduced appropriate therapies, shocks, and all-cause mortality. (Avoid DeliVering TherApies for Non-sustained Arrhythmias in ICD PatiEnts III [ADVANCEIII]; NCT00617175). Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Ozaki, Hiroya; Tominaga, Jun-Ya; Hamanaka, Ryo; Sumi, Mayumi; Chiang, Pao-Chang; Tanaka, Motohiro; Koga, Yoshiyuki; Yoshida, Noriaki
2015-01-01
The porpose of this study was to determine the optimal length of power arms for achieving controlled anterior tooth movement in segmented arch mechanics combined with power arm. A three-dimensional finite element method was applied for the simulation of en masse anterior tooth retraction in segmented power arm mechanics. The type of tooth movement, namely, the location of center of rotation of the maxillary central incisor in association with power arm length, was calculated after the retraction force was applied. When a 0.017 × 0.022-in archwire was inserted into the 0.018-in slot bracket, bodily movement was obtained at 9.1 mm length of power arm, namely, at the level of 1.8 mm above the center of resistance. In case a 0.018 × 0.025-in full-size archwire was used, bodily movement of the tooth was produced at the power arm length of 7.0 mm, namely, at the level of 0.3 mm below the center of resistance. Segmented arch mechanics required shorter length of power arms for achieving any type of controlled anterior tooth movement as compared to sliding mechanics. Therefore, this space closing mechanics could be widely applied even for the patients whose gingivobuccal fold is shallow. The segmented arch mechanics combined with power arm could provide higher amount of moment-to-force ratio sufficient for controlled anterior tooth movement without generating friction, and vertical forces when applying retraction force parallel to the occlusal plane. It is, therefore, considered that the segmented power arm mechanics has a simple appliance design and allows more efficient and controllable tooth movement.
Time-Delay Interferometry for Space-based Gravitational Wave Searches
NASA Technical Reports Server (NTRS)
Armstrong, J.; Estabrook, F.; Tinto, M.
1999-01-01
Ground-based, equal-arm-length laser interferometers are being built to measure high-frequency astrophysical graviatational waves. Because of the arm-length equality, laser light experiences the same delay in each arm and thus phase or frequency noise from the laser itself precisely cancels at the photodetector.
Uriarte, Iker; Hernández, Jorge; Dörner, Jessica; Paschke, Kurt; Farías, Ana; Crovetto, Enzo; Rosas, Carlos
2010-04-01
Globally, octopus larviculture is one of the challenges faced in the attempt to diversify aquaculture and achieve cephalopod farming. Currently, only juveniles of Octopus vulgaris, Octopus joubini, and Enteroctopus dofleini have been obtained at an experimental level. This is the first study to look at the characteristics of planktonic and benthic Robsonella fontaniana juveniles in an effort to analyze the morphometric changes occurring during their planktonic and benthic phases and to explore the feasibility of obtaining settlement under controlled conditions. The morphometric measurements varied exponentially over time and did not show different tendencies before and after settlement. Mantle growth in relation to total length fit a logarithmic regression, whereas arm length and eye diameter increased linearly with respect to total length throughout the entire paralarval and juvenile periods. This suggests that the size of the mantle decreases with age in proportion to the total octopus length, whereas the organs more directly involved in catching prey tend to increase in direct proportion to the total length. The present study shows that R. fontaniana can be reared from hatching through the final paralarval stage on a diet of Lithodes santolla (king crab) zoeae; after settlement, the juveniles can be reared on a diet of crab such as Petrolisthes.
Optimal Body Size and Limb Length Ratios Associated with 100-m Personal-Best Swim Speeds.
Nevill, Alan M; Oxford, Samuel W; Duncan, Michael J
2015-08-01
This study aims to identify optimal body size and limb segment length ratios associated with 100-m personal-best (PB) swim speeds in children and adolescents. Fifty national-standard youth swimmers (21 males and 29 females age 11-16 yr; mean ± SD age, 13.5 ± 1.5 yr) participated in the study. Anthropometry comprised stature; body mass; skinfolds; maturity offset; upper arm, lower arm, and hand lengths; and upper leg, lower leg, and foot lengths. Swimming performance was taken as the PB time recorded in competition for the 100-m freestyle swim. To identify the optimal body size and body composition components associated with 100-m PB swim speeds (having controlled for age and maturity offset), we adopted a multiplicative allometric log-linear regression model, which was refined using backward elimination. Lean body mass was the singularly most important whole-body characteristic. Stature and body mass did not contribute to the model, suggesting that the advantage of longer levers was limb-specific rather than a general whole-body advantage. The allometric model also identified that having greater limb segment length ratios [i.e., arm ratio = (low arm)/(upper arm); foot-to-leg ratio = (foot)/(lower leg)] was key to PB swim speeds. It is only by adopting multiplicative allometric models that the above mentioned ratios could have been derived. The advantage of having a greater lower arm is clear; however, having a shorter upper arm (achieved by adopting a closer elbow angle technique or by possessing a naturally endowed shorter upper arm), at the same time, is a new insight into swimming performance. A greater foot-to-lower-leg ratio suggests that a combination of larger feet and shorter lower leg length may also benefit PB swim speeds.
30 CFR 1206.361 - How will ONRR determine whether my royalty or direct use fee payments are correct?
Code of Federal Regulations, 2012 CFR
2012-07-01
... proceeds either for the sale of electricity or the sale of a geothermal resource, in conducting reviews and audits ONRR will examine whether your sales contract reflects the total consideration actually... information justifying your gross proceeds. (c) For arm's-length sales, you have the burden of demonstrating...
30 CFR 1206.361 - How will ONRR determine whether my royalty or direct use fee payments are correct?
Code of Federal Regulations, 2011 CFR
2011-07-01
... proceeds either for the sale of electricity or the sale of a geothermal resource, in conducting reviews and audits ONRR will examine whether your sales contract reflects the total consideration actually... information justifying your gross proceeds. (c) For arm's-length sales, you have the burden of demonstrating...
30 CFR 1206.361 - How will ONRR determine whether my royalty or direct use fee payments are correct?
Code of Federal Regulations, 2014 CFR
2014-07-01
... proceeds either for the sale of electricity or the sale of a geothermal resource, in conducting reviews and audits ONRR will examine whether your sales contract reflects the total consideration actually... information justifying your gross proceeds. (c) For arm's-length sales, you have the burden of demonstrating...
Extending body space in immersive virtual reality: a very long arm illusion.
Kilteni, Konstantina; Normand, Jean-Marie; Sanchez-Vives, Maria V; Slater, Mel
2012-01-01
Recent studies have shown that a fake body part can be incorporated into human body representation through synchronous multisensory stimulation on the fake and corresponding real body part - the most famous example being the Rubber Hand Illusion. However, the extent to which gross asymmetries in the fake body can be assimilated remains unknown. Participants experienced, through a head-tracked stereo head-mounted display a virtual body coincident with their real body. There were 5 conditions in a between-groups experiment, with 10 participants per condition. In all conditions there was visuo-motor congruence between the real and virtual dominant arm. In an Incongruent condition (I), where the virtual arm length was equal to the real length, there was visuo-tactile incongruence. In four Congruent conditions there was visuo-tactile congruence, but the virtual arm lengths were either equal to (C1), double (C2), triple (C3) or quadruple (C4) the real ones. Questionnaire scores and defensive withdrawal movements in response to a threat showed that the overall level of ownership was high in both C1 and I, and there was no significant difference between these conditions. Additionally, participants experienced ownership over the virtual arm up to three times the length of the real one, and less strongly at four times the length. The illusion did decline, however, with the length of the virtual arm. In the C2-C4 conditions although a measure of proprioceptive drift positively correlated with virtual arm length, there was no correlation between the drift and ownership of the virtual arm, suggesting different underlying mechanisms between ownership and drift. Overall, these findings extend and enrich previous results that multisensory and sensorimotor information can reconstruct our perception of the body shape, size and symmetry even when this is not consistent with normal body proportions.
Extending Body Space in Immersive Virtual Reality: A Very Long Arm Illusion
Kilteni, Konstantina; Normand, Jean-Marie; Sanchez-Vives, Maria V.; Slater, Mel
2012-01-01
Recent studies have shown that a fake body part can be incorporated into human body representation through synchronous multisensory stimulation on the fake and corresponding real body part – the most famous example being the Rubber Hand Illusion. However, the extent to which gross asymmetries in the fake body can be assimilated remains unknown. Participants experienced, through a head-tracked stereo head-mounted display a virtual body coincident with their real body. There were 5 conditions in a between-groups experiment, with 10 participants per condition. In all conditions there was visuo-motor congruence between the real and virtual dominant arm. In an Incongruent condition (I), where the virtual arm length was equal to the real length, there was visuo-tactile incongruence. In four Congruent conditions there was visuo-tactile congruence, but the virtual arm lengths were either equal to (C1), double (C2), triple (C3) or quadruple (C4) the real ones. Questionnaire scores and defensive withdrawal movements in response to a threat showed that the overall level of ownership was high in both C1 and I, and there was no significant difference between these conditions. Additionally, participants experienced ownership over the virtual arm up to three times the length of the real one, and less strongly at four times the length. The illusion did decline, however, with the length of the virtual arm. In the C2–C4 conditions although a measure of proprioceptive drift positively correlated with virtual arm length, there was no correlation between the drift and ownership of the virtual arm, suggesting different underlying mechanisms between ownership and drift. Overall, these findings extend and enrich previous results that multisensory and sensorimotor information can reconstruct our perception of the body shape, size and symmetry even when this is not consistent with normal body proportions. PMID:22829891
A Fine Physical Map of the Rice Chromosome 4
Zhao, Qiang; Zhang, Yu; Cheng, Zhukuan; Chen, Mingsheng; Wang, Shengyue; Feng, Qi; Huang, Yucheng; Li, Ying; Tang, Yesheng; Zhou, Bo; Chen, Zhehua; Yu, Shuliang; Zhu, Jingjie; Hu, Xin; Mu, Jie; Ying, Kai; Hao, Pei; Zhang, Lei; Lu, Yiqi; Zhang, Lei S.; Liu, Yilei; Yu, Zhen; Fan, Danlin; Weng, Qijun; Chen, Ling; Lu, Tingting; Liu, Xiaohui; Jia, Peixin; Sun, Tongguo; Wu, Yongrui; Zhang, Yujun; Lu, Ying; Li, Can; Wang, Rong; Lei, Haiyan; Li, Tao; Hu, Hao; Wu, Mei; Zhang, Runquan; Guan, Jianping; Zhu, Jia; Fu, Gang; Gu, Minghong; Hong, Guofan; Xue, Yongbiao; Wing, Rod; Jiang, Jiming; Han, Bin
2002-01-01
As part of an international effort to completely sequence the rice genome, we have produced a fine bacterial artificial chromosome (BAC)-based physical map of the Oryza sativa japonica Nipponbare chromosome 4 through an integration of 114 sequenced BAC clones from a taxonomically related subspecies O. sativa indica Guangluai 4 and 182 RFLP and 407 expressed sequence tag (EST) markers with the fingerprinted data of the Nipponbare genome. The map consists of 11 contigs with a total length of 34.5 Mb covering 94% of the estimated chromosome size (36.8 Mb). BAC clones corresponding to telomeres, as well as to the centromere position, were determined by BAC-pachytene chromosome fluorescence in situ hybridization (FISH). This gave rise to an estimated length ratio of 5.13 for the long arm and 2.9 for the short arm (on the basis of the physical map), which indicates that the short arm is a highly condensed one. The FISH analysis and physical mapping also showed that the short arm and the pericentromeric region of the long arm are rich in heterochromatin, which occupied 45% of the chromosome, indicating that this chromosome is likely very difficult to sequence. To our knowledge, this map provides the first example of a rapid and reliable physical mapping on the basis of the integration of the data from two taxonomically related subspecies. [The following individuals and institutions kindly provided reagents, samples, or unpublished information as indicated in the paper: S. McCouch, T. Sasaki, and Monsanto.] PMID:11997348
Goto, Eita
2011-01-01
Low birthweight should be identified early, even in developing countries where birthweight cannot be easily measured due to the absence of scales and trained staff. This meta-analysis evaluated and compared the use of other anthropometric measurements at birth to predict low birthweight. All studies of medium to high quality (Quality Assessment of Diagnostic Accuracy Studies score ≥8) published in English were included. Bivariate random-effects meta-analysis and hierarchical summary receiver operating characteristic curves were used. A total of 69 studies evaluated foot length or the circumference of the chest, (mid-upper) arm, or thigh (n = 8, 25, 30, and 6, respectively). Chest circumference and arm circumference had areas under the curve >0.9 (0.95 for both), pooled positive likelihood ratios >5 (8.7 and 10.3, respectively), and negative likelihood ratios <0.2 (0.13 and 0.17, respectively); thigh circumference and foot length were less accurate. There was no substantial difference between chest and arm circumference with respect to pooled sensitivity (0.88 vs. 0.84, P = 0.505), specificity (0.90 vs. 0.92, P = 0.565), or diagnostic odds ratio (67 vs. 60, P = 0.552). However, as compared with arm circumference, chest circumference showed greater clustering of observations on the hierarchical summary receiver operating characteristic curve and narrower 95% confidence and prediction regions. Chest circumference and arm circumference have similarly high, although not confirmative, accuracy in predicting low birthweight; however, chest circumference appears to be more precise.
Integral equation theory study on the phase separation in star polymer nanocomposite melts.
Zhao, Lei; Li, Yi-Gui; Zhong, Chongli
2007-10-21
The polymer reference interaction site model theory is used to investigate phase separation in star polymer nanocomposite melts. Two kinds of spinodal curves were obtained: classic fluid phase boundary for relatively low nanoparticle-monomer attraction strength and network phase boundary for relatively high nanoparticle-monomer attraction strength. The network phase boundaries are much more sensitive with nanoparticle-monomer attraction strength than the fluid phase boundaries. The interference among the arm number, arm length, and nanoparticle-monomer attraction strength was systematically investigated. When the arm lengths are short, the network phase boundary shows a marked shift toward less miscibility with increasing arm number. When the arm lengths are long enough, the network phase boundaries show opposite trends. There exists a crossover arm number value for star polymer nanocomposite melts, below which the network phase separation is consistent with that of chain polymer nanocomposite melts. However, the network phase separation shows qualitatively different behaviors when the arm number is larger than this value.
Uga, Yusaku; Assaranurak, Ithipong; Kitomi, Yuka; Larson, Brandon G; Craft, Eric J; Shaff, Jon E; McCouch, Susan R; Kochian, Leon V
2018-04-20
Genetic improvement of root system architecture is a promising approach for improved uptake of water and mineral nutrients distributed unevenly in the soil. To identify genomic regions associated with the length of different root types in rice, we quantified root system architecture in a set of 26 chromosome segment substitution lines derived from a cross between lowland indica rice, IR64, and upland tropical japonica rice, Kinandang Patong, (IK-CSSLs), using 2D & 3D root phenotyping platforms. Lengths of seminal and crown roots in the IK-CSSLs grown under hydroponic conditions were measured by 2D image analysis (RootReader2D). Twelve CSSLs showed significantly longer seminal root length than the recurrent parent IR64. Of these, 8 CSSLs also exhibited longer total length of the three longest crown roots compared to IR64. Three-dimensional image analysis (RootReader3D) for these CSSLs grown in gellan gum revealed that only one CSSL, SL1003, showed significantly longer total root length than IR64. To characterize the root morphology of SL1003 under soil conditions, SL1003 was grown in Turface, a soil-like growth media, and roots were quantified using RootReader3D. SL1003 had larger total root length and increased total crown root length than did IR64, although its seminal root length was similar to that of IR64. The larger TRL in SL1003 may be due to increased crown root length. SL1003 carries an introgression from Kinandang Patong on the long arm of chromosome 1 in the genetic background of IR64. We conclude that this region harbors a QTL controlling crown root elongation.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-11
...-length AUDIT PROCESS--See Note. transmission contracts, production and operating agreements and related... interest. 1206.354(n) Submit all arm's-length AUDIT PROCESS--See Note. power plant contracts, production... production method. 1206.458(c)(1)(iv) and (c)(2)(vi).. Submit arm's-length washing AUDIT PROCESS--See Note...
27 CFR 53.96 - Constructive sale price; special rule for arm's-length sales.
Code of Federal Regulations, 2010 CFR
2010-04-01
... as not being at retail or to retailers, or both, if the industry dollar volume of sales which are at retail or to retailers, or both, is less than half the total industry dollar volume of sales at all... 27 Alcohol, Tobacco Products and Firearms 2 2010-04-01 2010-04-01 false Constructive sale price...
NASA Astrophysics Data System (ADS)
Gao, Mingxing; Jing, Hongwei; Cao, Xuedong; Chen, Lin; Yang, Jie
2015-08-01
When using the swing arm profilometer (SAP) to measure the aspheric mirror and the off-axis aspheric mirror, the error of the effective arm length of the SAP has an obvious influence on the measurement result. In order to reduce the influence of the effective arm length and increase the measurement accuracy of the SAP, the laser tracker is adopted to measure the effective arm length. Because the space position relationship of the probe system for the SAP is needed to measured before using the laser tracker, the point source microscope (PSM) is used to measure the space positional relationship. The measurement principle of the PSM and other applications are introduced; the accuracy and repeatability of this technology are analysed; the advantages and disadvantages of this technology are summarized.
Reference values of anthropometric measurements in Dutch children. The Oosterwolde Study.
Gerver, W J; Drayer, N M; Schaafsma, W
1989-03-01
In the period 1979-1980 the following anthropometric measurements were recorded in 2351 healthy Dutch children from 0-17 years of age: height, weight, sitting height, arm span, lengths of upper-arm, lower-arm and hand, tibial length, foot length, biacromial diameter, biiliacal diameter, and head circumference. Corresponding percentile values were constructed on the basis of normality assumptions, the mean and standard deviation at age t being determined by a cubic spline approximation. The results are compared with other studies and given in the form of growth charts.
McGrath, Eric; Du, Wei; Rajpurkar, Madhvi
2018-03-01
Ethanol lock therapy (ELT) with systemic antimicrobial therapy is a promising therapy for catheter-related infection (CRI). The impact of ELT timing on treatment efficacy and costs is unknown. A prospective study was conducted in the Hematology/Oncology Unit at the Children's Hospital of Michigan. Patients with suspected CRI were randomized to Preemptive ELT arm or Rescue ELT arm after positive culture. Five cases in Preemptive arm and 9 in Rescue arm had a confirmed CRI. All cases cleared infection with line salvage with no adverse events due to ELT or recurrence within 14 days. Our data showed a trend toward 36% reduction in average hospital costs and 40% reduction in average length of stay in Preemptive arm over Rescue arm. Although a small study, our data on preemptive ELT with systemic antimicrobial therapy suggest a potentially important treatment strategy in reducing length of stay as well as hospital costs.
Game Performance Evaluation in Male Goalball Players
Molik, Bartosz; Morgulec-Adamowicz, Natalia; Kosmol, Andrzej; Perkowski, Krzysztof; Bednarczuk, Grzegorz; Skowroński, Waldemar; Gomez, Miguel Angel; Koc, Krzysztof; Rutkowska, Izabela; Szyman, Robert J
2015-01-01
Goalball is a Paralympic sport exclusively for athletes who are visually impaired and blind. The aims of this study were twofold: to describe game performance of elite male goalball players based upon the degree of visual impairment, and to determine if game performance was related to anthropometric characteristics of elite male goalball players. The study sample consisted of 44 male goalball athletes. A total of 38 games were recorded during the Summer Paralympic Games in London 2012. Observations were reported using the Game Efficiency Sheet for Goalball. Additional anthropometric measurements included body mass (kg), body height (cm), the arm span (cm) and length of the body in the defensive position (cm). The results differentiating both groups showed that the players with total blindness obtained higher means than the players with visual impairment for game indicators such as the sum of defense (p = 0.03) and the sum of good defense (p = 0.04). The players with visual impairment obtained higher results than those with total blindness for attack efficiency (p = 0.04), the sum of penalty defenses (p = 0.01), and fouls (p = 0.01). The study showed that athletes with blindness demonstrated higher game performance in defence. However, athletes with visual impairment presented higher efficiency in offensive actions. The analyses confirmed that body mass, body height, the arm span and length of the body in the defensive position did not differentiate players’ performance at the elite level. PMID:26834872
Somatic Profile of the Elite Boulderers in Poland.
Ozimek, Mariusz; Krawczyk, Marcin; Zadarko, Emilian; Barabasz, Zbigniew; Ambroży, Tadeusz; Stanula, Arkadiusz; Mucha, Dawid K; Jurczak, Adam; Mucha, Dariusz
2017-04-01
Ozimek, M, Krawczyk, M, Zadarko, E, Barabasz, Z, Ambroży, T, Stanula, A, Mucha, DK, Jurczak, A, and Mucha, D. Somatic profile of the elite boulderers in Poland. J Strength Cond Res 31(4): 963-970, 2017-The study was designed to determine the values of selected somatic characteristics, body proportions, and the somatotype of elite bouldering climbers in Poland and to establish the relationships between the values of the somatic characteristics and climber's performance in bouldering. The study was conducted in a group of elite sport climbers (n = 10) who were ranked by the Polish Mountaineering Association in 2011, 2012, and 2013. The anthropometric measurements were made according to the relevant rules and standards. The results were used to calculate the values of somatic variables and body proportion indices for the climbers and to establish their somatotype. The results were compared with the data on untrained students (n = 165). The boulderers were found to differ significantly from the controls regarding body height (p < 0.01), body mass (p ≤ 0.05), body density (p < 0.01), fat mass percentage (FM%) (p < 0.01), fat mass (FMkg) (p < 0.01), lean body mass (p ≤ 0.05), arm span (p ≤ 0.05), and leg length (p < 0.01). Body proportions in the groups significantly differed in the arm length index (p < 0.01), arm-to-leg length ratio (p < 0.01), and in the indices of the forearm (p < 0.01), thigh (p < 0.01), and lower leg (p ≤ 0.05) muscles. With regard to the somatotypes of the analyzed groups, the biggest differences were observed for the levels of mesomorphy (NS) and endomorphy, the latter being statistically significant (p < 0.01). The strongest and significant correlations between the competitive level of the climbers and the values of their somatic characteristics were established for FM% (r = -0.81), fat mass (in kilograms) (r = -0.82), body density (r = 0.81), endomorphy (r = -0.74), arm length (r = 0.77), and the arm length index (r = 0.80). The results of linear regression showed that the competitive level of a bouldering climber was significantly explained (p < 0.01) by fat mass (in kilograms) and the value of the arm length index. A high level of performance in bouldering is related to small stature (an ecto-mesomorph somatotype) and a low body fat percentage (low endomorphy). Regarding body proportions, greater than average arm length to body height ratio and well-developed musculature of the limbs are required for a boulderer to perform on a competitive level. High arm length index and low body fat percentage represent the strongest determinants of performance in bouldering. It can be assumed that arm length index has a high diagnostic value for recruitment and selection of climbers.
30 CFR 1206.57 - Determination of transportation allowances.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Determination of transportation allowances... transportation allowances. (a) Arm's-length transportation contracts. (1)(i) For transportation costs incurred by a lessee under an arm's-length contract, the transportation allowance shall be the reasonable...
Bieg, Lothar F.
1993-01-12
A method for machining a workpiece. The method includes the use of a rotary cutting tool mounted on the end of a movable arm. The arm is adapted to move in a plane perpendicular to the axis of rotation of the cutting tool. The cutting tool has cutting teeth to cut chips of material off of the workpiece in a predetermined size and shape to facilitate better removal of the chips from the workpiece. The teeth can be of different type and length to permit the tool to both rough cut and finish cut the workpiece during machining. The total depth of cut is divided by the number of tool teeth, so that the longest tool always performs the finishing cut.
Colloidosomes formed by nonpolar/polar/nonpolar nanoball amphiphiles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, Hung-Yu; Sheng, Yu-Jane, E-mail: yjsheng@ntu.edu.tw, E-mail: hktsao@cc.ncu.edu.tw; Tu, Sheng-Hung
2014-08-07
Fullerene-based amphiphiles are able to form bilayer vesicles in aqueous solution. In this study, the self-assembly behavior of polymer-tethered nanoballs (NBs) with nonpolar/polar/nonpolar (n-p-n{sup ′}) motif in a selective solvent is investigated by dissipative particle dynamics. A model NB bears two hydrophobic polymeric arms (n{sup ′}-part) tethered on an extremely hydrophobic NB (n-part) with hydrophilic patch (p-part) patterned on its surface. Dependent on the hydrophobicity and length of tethered arms, three types of aggregates are exhibited, including NB vesicle, core-shell micelle, and segmented-worm. NB vesicles are developed for a wide range of hydrophobic arm lengths. The presence of tethered armsmore » perturbs the bilayer structure formed by NBs. The structural properties including the order parameter, membrane thickness, and area density of the inner leaflet decrease with increasing the arm length. These results indicate that for NBs with longer arms, the extent of interdigitation in the membrane rises so that the overcrowded arms in the inner corona are relaxed. The transport and mechanical properties are evaluated as well. As the arm length grows, the permeability increases significantly because the steric bulk of tethered arms loosens the packing of NBs. By contrast, the membrane tension decreases owing to the reduction of NB/solvent contacts by the polymer corona. Although fusion can reduce membrane tension, NB vesicles show strong resistance to fusion. Moreover, the size-dependent behavior observed in small liposomes is not significant for NB vesicles due to isotropic geometry of NB. Our simulation results are consistent with the experimental findings.« less
30 CFR 1206.262 - Determination of transportation allowances.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 3 2013-07-01 2013-07-01 false Determination of transportation allowances... transportation allowances. (a) Arm's-length contracts. (1) For transportation costs incurred by a lessee pursuant to an arm's-length contract, the transportation allowance shall be the reasonable, actual costs...
30 CFR 1206.262 - Determination of transportation allowances.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Determination of transportation allowances... of transportation allowances. (a) Arm's-length contracts. (1) For transportation costs incurred by a lessee pursuant to an arm's-length contract, the transportation allowance shall be the reasonable, actual...
30 CFR 1206.262 - Determination of transportation allowances.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 3 2014-07-01 2014-07-01 false Determination of transportation allowances... transportation allowances. (a) Arm's-length contracts. (1) For transportation costs incurred by a lessee pursuant to an arm's-length contract, the transportation allowance shall be the reasonable, actual costs...
30 CFR 1206.461 - Determination of transportation allowances.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Determination of transportation allowances... of transportation allowances. (a) Arm's-length contracts. (1) For transportation costs incurred by a lessee pursuant to an arm's-length contract, the transportation allowance shall be the reasonable, actual...
30 CFR 1206.262 - Determination of transportation allowances.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 3 2012-07-01 2012-07-01 false Determination of transportation allowances... transportation allowances. (a) Arm's-length contracts. (1) For transportation costs incurred by a lessee pursuant to an arm's-length contract, the transportation allowance shall be the reasonable, actual costs...
Hand grip strength and anthropometric characteristics in Italian female national basketball teams.
Pizzigalli, Luisa; Micheletti Cremasco, Margherita; LA Torre, Antonio; Rainoldi, Alberto; Benis, Roberto
2017-05-01
The aim of this study was to investigate the influence of hand and body dimensions on hand grip strength and to define a reference scale for talent identification in basketball players. Body and hand anthropometric data and the maximal handgrip strength of 109 female Italian basketball National players (Under14-Seniores) were measured. Handgrip strength and arm length trend increased, raising the statistical significant differences only for players from the age of 19 (U20, Seniores) with respect to sub-elite groups (U14, U15) (P<0.05). Handgrip strength showed low positive correlations with height and Body Mass Index but a positive relationships with arm length (r=0.5; P<0.001). Findings underline training and years of practice have effects on increasing handgrip strength. Data show that to select female basketball players by arm length means selecting by handgrip strength. Thus it is possible to suggest that in addition to height, arm length could also be considered a useful parameter in young female talent identification.
Anthropometric changes in elite male water polo players: survey in 1980 and 1995.
Lozovina, Vinko; Pavicić, Leo
2004-04-01
To assess the differences in anthropometric parameters, body fat, body mass index (BMI), and body density induced by sport-specific morphological optimization (adaptation) between two generations (1980 and 1995) of male elite water polo players. The survey included a total of 160 elite male water polo players, all members of the top clubs in Croatia. The 1980's generation consisted of 95 players (71.9% of target population) aged between 18 and 32 years, and the 1995's generation included 65 players (50% of target population) aged between 19 and 29 years. Trained and qualified anthropometrists performed the measurements under standardized experimental conditions and in accordance with the procedures described by the International Biological Program. They measured 23 anthropometric variables reflecting basic human body characteristics described by skeletal bone lengths (total leg length, total arm length, hand length, foot length, and height), breadths (hand at proximal phalanges, foot in metatarsal area, biacromial, biiliocristal, biepycondylar femur, biepycondyar humerus, and radio-ulnar wrist breadth), girths (chest, arm, forearm, thigh, and calf girth), skinfold thickness as a measure of subcutaneous adiposity (triceps, subscapular, axillary, calf, and abdominal skinfold thickness), and mass. Additionally, estimates of body mass index (BMI), body density, and percentage of body fat were calculated from the primary measures. Comparison between anthropometric measures of the two generations of water polo players revealed a positive trend in body skeletal measures and negative trend in body adiposity measures. Most noteworthy differences (d) were an increase in height (d=37.3 mm, p
Resonator design and performance estimation for a space-based laser transmitter
NASA Astrophysics Data System (ADS)
Agrawal, Lalita; Bhardwaj, Atul; Pal, Suranjan; Kamalakar, J. A.
2006-12-01
Development of a laser transmitter for space applications is a highly challenging task. The laser must be rugged, reliable, lightweight, compact and energy efficient. Most of these features are inherently achieved by diode pumping of solid state lasers. Overall system reliability can further be improved by appropriate optical design of the laser resonator besides selection of suitable electro-optical and opto-mechanical components. This paper presents the design details and the theoretically estimated performance of a crossed-porro prism based, folded Z-shaped laser resonator. A symmetrically pumped Nd: YAG laser rod of 3 mm diameter and 60 mm length is placed in the gain arm with total input peak power of 1800 W from laser diode arrays. Electro-optical Q-switching is achieved through a combination of a polarizer, a fractional waveplate and LiNbO 3 Q-switch crystal (9 x 9 x 25 mm) placed in the feedback arm. Polarization coupled output is obtained by optimizing azimuth angle of quarter wave plate placed in the gain arm. Theoretical estimation of laser output energy and pulse width has been carried out by varying input power levels and resonator length to analyse the performance tolerances. The designed system is capable of meeting the objective of generating laser pulses of 10 ns duration and 30 mJ energy @ 10 Hz.
Keogh, Justin W L; Marnewick, Michel C; Maulder, Peter S; Nortje, Jacques P; Hume, Patria A; Bradshaw, Elizabeth J
2009-09-01
The present study assessed the anthropometric profile (International Society for the Advancement of Kinanthropometry protocol), flexibility, muscular strength, and endurance of 20 male golfers. These data were collected in order to determine: a) the relationship between these kinanthropometric measures and clubhead velocity; and b) if these measures could distinguish low-handicap (LHG) and high-handicap (HHG) golfers. Ten LHG (handicap of 0.3 +/- 0.5) and 10 HHG (handicap of 20.3 +/- 2.4) performed 10 swings for maximum velocity and accuracy with their own 5-iron golf club at a wall-mounted target. LHG hit the target significantly more (115%) and had a 12% faster clubhead velocity than HHG (p < 0.01). The LHG also had significantly (28%) greater golf swing-specific cable woodchop (GSCWC) strength (p < 0.01) and tendencies for greater (30%) bench press strength and longer (5%) upper am and total arm (4%) length and less (24%) right hip internal rotation than HHG (0.01 < p < 0.05). GSCWC strength was significantly correlated to clubhead velocity (p < 0.01), with bench press and hack squat strength as well as upper arm and total arm length also approaching significance (0.01 < p < 0.05). Golfers with high GSCWC strength and perhaps greater bench press strength and longer arms may therefore be at a competitive advantage, as these characteristics allow the production of greater clubhead velocity and resulting ball displacement. Such results have implications for golf talent identification programs and for the prescription and monitoring of golf conditioning programs. While golf conditioning programs may have many aims, specific trunk rotation exercises need to be included if increased clubhead velocity is the goal. Muscular hypertrophy development may not need to be emphasized as it could reduce golf performance by limiting range of motion and/or increasing moment of inertia.
Influence of pectoralis minor and upper trapezius lengths on observable scapular dyskinesis.
Yeşilyaprak, Sevgi Sevi; Yüksel, Ertuğrul; Kalkan, Serpil
2016-05-01
Although a relationship between short pectoralis minor and upper trapezius and scapular dyskinesis has been postulated, no studies have investigated this theory. Understanding the effect of these muscle lengths on observable scapular dyskinesis may aid in determining risks and therefore making treatment decisions. Being aware of the magnitude of this effect would help gauge the significance of risks involved. Our aim was to evaluate the influence of pectoralis minor and upper trapezius lengths on scapular dyskinesis. Cross-sectional study. University research laboratory. Asymptomatic participants (n = 148; 296 arms) were evaluated. Scapular Dyskinesis Test (SDT) was used to identify scapular dyskinesis, Pectoralis Minor Index (PMI) and Upper Trapezius Length Testing were used to determine muscle length. SDT+ arms had shorter pectoralis minor resting length (PMI: 7.49 ± 0.38) (p < 0.001) and greater incidence of short upper trapezius (ISUT) (66.7%) (p < 0.001) compared to SDT- arms (PMI:8.58 ± 0.75, ISUT:22.5%). With each decrease in PMI, the likelihood of having scapular dyskinesis increased 96% (p < 0.001). Arms with short upper trapezius were 2.049 times more likely to exhibit scapular dyskinesis than those with normal length (p = 0.042). Having a shorter pectoralis minor and upper trapezius length substantially increased the likelihood of having visually observable scapular dyskinesis. Copyright © 2015 Elsevier Ltd. All rights reserved.
Teixeira, Jéssica Socas; Gomes, Mirian Martins
2014-01-01
Objective: To perform anthropometric assessment of patients with quadriplegic, chronic non-progressive encephalopathy, comparing two distinct references of nutritional classification and to compare the estimated height to the length measured by stadiometer. Method: Cross-sectional study including 0-3-year children with quadriplegic chronic non-progressive encephalopathy in secondary public hospital. Length, weight, arm circumference, triceps skinfold and knee height were measured. The arm muscle circumference and estimated height were calculated. The following relations were evaluated: weight-for-age, length-for-age and weight-for-length, using as reference the charts of the World Health Organization (WHO) and those proposed by Krick et al. Results: Fourteen children with a mean age of 21 months were evaluated. Assessment of anthropometric indicators showed significant difference between the two classification methods to assess nutritional indicators length/age (p=0.014), weight/age (p=0.014) and weight/length (p=0.001). There was significant correlation between measured length and estimated height (r=0.796, p=0.001). Evaluation of arm circumference and triceps skinfold showed that most patients presented some degree of malnutrition. According to arm muscle circumference, most were eutrophic. Conclusions: Specific curves for children with chronic non-progressive encephalopathy appear to underestimate malnutrition when one takes into account indicators involving weight. Curves developed for healthy children can be a good option for clinical practice and weight-for-length indicator and body composition measurements should be considered as complementary tools. PMID:25479849
Comparison of rotator cuff muscle architecture between humans and other selected vertebrate species
Mathewson, Margie A.; Kwan, Alan; Eng, Carolyn M.; Lieber, Richard L.; Ward, Samuel R.
2014-01-01
In this study, we compare rotator cuff muscle architecture of typically used animal models with that of humans and quantify the scaling relationships of these muscles across mammals. The four muscles that correspond to the human rotator cuff – supraspinatus, infraspinatus, subscapularis and teres minor – of 10 commonly studied animals were excised and subjected to a series of comparative measurements. When body mass among animals was regressed against physiological cross-sectional area, muscle mass and normalized fiber length, the confidence intervals suggested geometric scaling but did not exclude other scaling relationships. Based on the architectural difference index (ADI), a combined measure of fiber length-to-moment arm ratio, fiber length-to-muscle length ratio and the fraction of the total rotator cuff physiological cross-sectional area contributed by each muscle, chimpanzees were found to be the most similar to humans (ADI=2.15), followed closely by capuchins (ADI=2.16). Interestingly, of the eight non-primates studied, smaller mammals such as mice, rats and dogs were more similar to humans in architectural parameters compared with larger mammals such as sheep, pigs or cows. The force production versus velocity trade-off (indicated by fiber length-to-moment arm ratio) and the excursion ability (indicated by fiber length-to-muscle length ratio) of humans were also most similar to those of primates, followed by the small mammals. Overall, primates provide the best architectural representation of human muscle architecture. However, based on the muscle architectural parameters of non-primates, smaller rather than larger mammals may be better models for studying muscles related to the human rotator cuff. PMID:24072803
Robotic Arm Comprising Two Bending Segments
NASA Technical Reports Server (NTRS)
Mehling, Joshua S.; Difler, Myron A.; Ambrose, Robert O.; Chu, Mars W.; Valvo, Michael C.
2010-01-01
The figure shows several aspects of an experimental robotic manipulator that includes a housing from which protrudes a tendril- or tentacle-like arm 1 cm thick and 1 m long. The arm consists of two collinear segments, each of which can be bent independently of the other, and the two segments can be bent simultaneously in different planes. The arm can be retracted to a minimum length or extended by any desired amount up to its full length. The arm can also be made to rotate about its own longitudinal axis. Some prior experimental robotic manipulators include single-segment bendable arms. Those arms are thicker and shorter than the present one. The present robotic manipulator serves as a prototype of future manipulators that, by virtue of the slenderness and multiple- bending capability of their arms, are expected to have sufficient dexterity for operation within spaces that would otherwise be inaccessible. Such manipulators could be especially well suited as means of minimally invasive inspection during construction and maintenance activities. Each of the two collinear bending arm segments is further subdivided into a series of collinear extension- and compression-type helical springs joined by threaded links. The extension springs occupy the majority of the length of the arm and engage passively in bending. The compression springs are used for actively controlled bending. Bending is effected by means of pairs of antagonistic tendons in the form of spectra gel spun polymer lines that are attached at specific threaded links and run the entire length of the arm inside the spring helix from the attachment links to motor-driven pulleys inside the housing. Two pairs of tendons, mounted in orthogonal planes that intersect along the longitudinal axis, are used to effect bending of each segment. The tendons for actuating the distal bending segment are in planes offset by an angle of 45 from those of the proximal bending segment: This configuration makes it possible to accommodate all eight tendons at the same diameter along the arm. The threaded links have central bores through which power and video wires can be strung (1) from a charge-coupled-device camera mounted on the tip of the arms (2) back along the interior of the arm into the housing and then (3) from within the housing to an external video monitor.
Hard turning micro-machine tool
DeVor, Richard E; Adair, Kurt; Kapoor, Shiv G
2013-10-22
A micro-scale apparatus for supporting a tool for hard turning comprises a base, a pivot coupled to the base, an actuator coupled to the base, and at least one member coupled to the actuator at one end and rotatably coupled to the pivot at another end. A tool mount is disposed on the at least one member. The at least one member defines a first lever arm between the pivot and the tool mount, and a second lever arm between the pivot and the actuator. The first lever arm has a length that is less than a length of the second lever arm. The actuator moves the tool mount along an arc.
Zhang, Yue-Hui; White, Ian; Potts, Eric; Mobasser, Jean-Pierre
2017-01-01
Study Design: Retrospective clinical study. Objectives: The aim of this study was to compare intraoperative conditions and clinical results of patients undergoing pre-psoas oblique lateral interbody fusion (OLIF) using navigation or conventional fluoroscopy (C-ARM) techniques. Methods: Forty-two patients (22 patients by navigation and 20 by fluoroscopy) underwent the OLIF procedure at 2 medical centers, and records were reviewed. Clinical data was collected and compared between the 2 groups. Patients were followed-up with a range of 6 to 24 months. Results: There were no significant differences on demographic data between groups. The navigation group had zero radiation exposure (RE) to the surgeon and radiation time compared to the C-ARM group, with total RE of 44.59 ± 26.65 mGy and radiation time of 88.30 ± 58.28 seconds (P < .05). The RE to the patient was significantly lower in the O-ARM group (9.38 mGy) compared to the C-ARM group (44.59 ± 26.65 mGy). Operating room time was slightly longer in the navigation group (2.49 ± 1.35 hours) compared to the C-ARM group (2.30 ± 1.17 hours; P > .05), although not statistically significant. No differences were found in estimated blood loss, length of hospitalization, surgery-related complications, and outcome scores with an average of 8-month follow-up. Conclusions: Compared with C-ARM techniques, using navigation can eliminate RE to surgeon and decrease RE to the patient, and it had no significant effect on operating time, estimated blood loss, length of hospitalization, or perioperative complications in the patients with OLIF procedure. This study shows that navigation is a safe alternative to fluoroscopy during the OLIF procedure in the treatment of degenerative lumbar conditions. PMID:28989845
76 FR 71343 - Ethics, Independence, Arm's-Length Role, Ex Parte Communications and Open Government
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-17
... FARM CREDIT ADMINISTRATION [FCA-PS-81; NV 11-25] Ethics, Independence, Arm's-Length Role, Ex Parte...) and the public. The FCA Board also is committed to the ethics principles and laws governing all Executive Branch employees and to the Agency's strong ethics program. DATES: Effective Date: November 7...
Tominaga, Jun-ya; Ozaki, Hiroya; Chiang, Pao-Chang; Sumi, Mayumi; Tanaka, Motohiro; Koga, Yoshiyuki; Bourauel, Christoph; Yoshida, Noriaki
2014-08-01
It has been found that controlled movement of the anterior teeth can be obtained by attaching a certain length of power arm onto an archwire in sliding mechanics. However, the impact of the archwire/bracket play on anterior tooth movement has not been clarified. The purpose of this study was to compare the effect of the power arm on anterior tooth movements with different dimensions of bracket slots and archwires. A 3-dimensional finite element method was used to simulate en-masse anterior tooth retraction in sliding mechanics. Displacements of the maxillary central incisor and the archwire deformation were calculated when applying retraction forces from different lengths of power arms. When a 0.017 × 0.022-in archwire was engaged into the 0.018-in slot bracket, bodily movement of the incisor was obtained with 9.1-mm length of the power arm. When a 0.022-in slot system was coupled with a 0.019 × 0.025-in archwire, bodily movement was observed with a power arm length of 11.6 mm. Archwire/bracket play has a remarkable impact on anterior tooth movement. An effective torque application to the anterior teeth becomes clinically difficult in sliding mechanics combined with power arms when the archwire/bracket play is large. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Yule, D.L.; Stockwell, J.D.; Schreiner, D.R.; Evrard, L.M.; Balge, M.; Hrabik, T.R.
2009-01-01
Management efforts to rehabilitate lake trout Salvelinus namaycush in Lake Superior have been successful and the recent increase in their numbers has led to interest in measuring biomass of pelagic prey fish species important to these predators. Lake Superior cisco Coregonus artedi currently support roe fisheries and determining the sustainability of these fisheries is an important management issue. We conducted acoustic and midwater trawl surveys of the western arm of Lake Superior during three periods: summer (July-August), October, and November 2006 to determine if a single survey can be timed to estimate biomass of both prey fish and spawning cisco. We evaluated our methods by comparing observed trawl catches of small (<250 mm total length) and large fish to expected trawl catches based on acoustic densities in the trawl path. We found the relationship between observed and expected catches approached unity over a wide range of densities, suggesting that our acoustic method provided reasonable estimates of fish density, and that midwater trawling methods were free of species- and size-selectivity issues. Rainbow smelt Osmerus mordax was by number the most common species captured in the nearshore (<80 m bathymetric depth) stratum during all three surveys, while kiyi Coregonus kiyi was predominant offshore except during November. Total biomass estimates of rainbow smelt in the western arm were similar during all three surveys, while total biomass of kiyi was similar between summer and October, but was lower in November. Total biomass of large cisco increased substantially in November, while small bloater Coregonus hoyi biomass was lower. We compared our summer 2006 estimates of total fish biomass to the results of a summer survey in 1997 and obtained similar results. We conclude that the temporal window for obtaining biomass estimates of pelagic prey species in the western arm of Lake Superior is wide (July through October), but estimating spawning cisco abundance is best done with a November survey.
Capillary electrophoresis-electrochemical detection microchip device and supporting circuits
Jackson, Douglas J [New Albany, IN; Roussel, Jr., Thomas J.; Crain, Mark M [Georgetown, IN; Baldwin, Richard P [Louisville, KY; Keynton, Robert S [Louisville, KY; Naber, John F [Prospect, KY; Walsh, Kevin M [Louisville, KY; Edelen, John G [Versailles, KY
2008-03-18
The present invention is a capillary electrophoresis device, comprising a substrate; a first channel in the substrate, and having a buffer arm and a detection arm; a second channel in the substrate intersecting the first channel, and having a sample arm and a waste arm; a buffer reservoir in fluid communication with the buffer arm; a waste reservoir in fluid communication with the waste arm; a sample reservoir in fluid communication with the sample arm; and a detection reservoir in fluid communication with the detection arm. The detection arm and the buffer arm are of substantially equal length.
Body Composition Predicts Growth in Infants and Toddlers With Chronic Liver Disease.
Hurtado-López, Erika F; Vásquez-Garibay, Edgar M; Trujillo, Xóchitl; Larrosa-Haro, Alfredo
2017-12-01
This cross-sectional study was conducted on 15 infants and toddlers with chronic liver disease to validate arm anthropometry as an accurate measure of body composition (BC) compared to dual-energy x-ray absorptiometry and to predict growth from BC. The z score means of the anthropometric indicators were <-2 standard deviation, except for body fat index and subscapular skinfold, which were between -2 and +2 standard deviation. Fat mass was predicted by arm adiposity indicators and fat-free mass by arm muscle area. Bone mineral content explained 87% of variation in length. Two multiple regression models predicted length: 1 with fat mass plus fat-free mass; and the second with fat mass and bone mineral content. These observations suggest that arm anthropometry is a useful tool to estimate BC and the nutritional status in infants and toddlers with chronic liver disease. Length and head circumference can be predicted by fat mass, fat-free mass, and bone mineral content.
Cell elongation is an adaptive response for clearing long chromatid arms from the cleavage plane
Kotadia, Shaila; Montembault, Emilie; Sullivan, William
2012-01-01
Chromosome segregation must be coordinated with cell cleavage to ensure correct transmission of the genome to daughter cells. Here we identify a novel mechanism by which Drosophila melanogaster neuronal stem cells coordinate sister chromatid segregation with cleavage furrow ingression. Cells adapted to a dramatic increase in chromatid arm length by transiently elongating during anaphase/telophase. The degree of cell elongation correlated with the length of the trailing chromatid arms and was concomitant with a slight increase in spindle length and an enlargement of the zone of cortical myosin distribution. Rho guanine-nucleotide exchange factor (Pebble)–depleted cells failed to elongate during segregation of long chromatids. As a result, Pebble-depleted adult flies exhibited morphological defects likely caused by cell death during development. These studies reveal a novel pathway linking trailing chromatid arms and cortical myosin that ensures the clearance of chromatids from the cleavage plane at the appropriate time during cytokinesis, thus preserving genome integrity. PMID:23185030
A PDMS microfiber Mach-Zehnder interferometer and determination of nanometer displacements
NASA Astrophysics Data System (ADS)
Martincek, Ivan; Kacik, Daniel
2018-01-01
A polydimethylsiloxane (PDMS) microfiber Mach-Zehnder interferometer (MZI), integrated between single-mode optical fibers (SMFs), is proposed and demonstrated experimentally. One arm of the interferometer consists of a microfiber of diameter 7 μm and length 270 μm; the second is an air arm. Due to the good elastic properties of PDMS microfiber, the length of the air arm of MZI can be changed by changing the distance between SMFs. The change in length of the air arm results in a change in the transmission characteristics of the MZI; thus, the relative displacement can be measured in the range 10-250 nm. By measuring the peak-to-peak amplitude of the difference in transmission powers (in dB), the smallest displacement by prepared MZI was determined as being on the order of a few nm for a ratio of intensities of 0.135. For a higher ratio of intensities of transmission functions, the smallest displacement could be determined on the order of subnanometers.
75 FR 2785 - Naturalization for Certain Persons in the U.S. Armed Forces
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-19
... 1615-AB85 Naturalization for Certain Persons in the U.S. Armed Forces AGENCY: U.S. Citizenship and... length of time a member of the United States Armed Forces has to serve to qualify for naturalization through service in the Armed Forces. In addition, this rule amends DHS regulations by implementing a...
Can we predict body height from segmental bone length measurements? A study of 3,647 children.
Cheng, J C; Leung, S S; Chiu, B S; Tse, P W; Lee, C W; Chan, A K; Xia, G; Leung, A K; Xu, Y Y
1998-01-01
It is well known that significant differences exist in the anthropometric data of different races and ethnic groups. This is a cross-sectional study on segmental bone length based on 3,647 Chinese children of equal sex distribution aged 3-18 years. The measurements included standing height, weight, arm span, foot length, and segmental bone length of the humerus, radius, ulna, and tibia. A normality growth chart of all the measured parameters was constructed. Statistical analysis of the results showed a very high linear correlation of height with arm span, foot length, and segmental bone lengths with a correlation coefficient of 0.96-0.99 for both sexes. No differences were found between the right and left side of all the segmental bone lengths. These Chinese children were found to have a proportional limb segmental length relative to the trunk.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoffmann, I., E-mail: ingo.hoffmann@tu-berlin.de; Institut Max von Laue-Paul Langevin; Malo de Molina, Paula
2014-01-21
The mesoscopic dynamical properties of oil-in-water microemulsions (MEs) bridged with telechelic polymers of different number of arms and with different lengths of hydrophobic stickers were studied with neutron spin-echo (NSE) probing the dynamics in the size range of individual ME droplets. These results then were compared to those of dynamicic light scattering (DLS) which allow to investigate the dynamics on a much larger length scale. Studies were performed as a function of the polymer concentration, number of polymer arms, and length of the hydrophobic end-group. In general it is observed that the polymer bridging has a rather small influence onmore » the local dynamics, despite the fact that the polymer addition leads to an increase of viscosity by several orders of magnitude. In contrast to results from rheology and DLS, where the dynamics on much larger length and time scales are observed, NSE shows that the linear polymer is more efficient in arresting the motion of individual ME droplets. This finding can be explained by a simple simulation, merely by the fact that the interconnection of droplets becomes more efficient with a decreasing number of arms. This means that the dynamics observed on the short and on the longer length scale depend in an opposite way on the number of arms and hydrophobic stickers.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
McKenzie, Kirk; Spero, Robert E.; Shaddock, Daniel A.
For the Laser Interferometer Space Antenna (LISA) to reach its design sensitivity, the coupling of the free-running laser frequency noise to the signal readout must be reduced by more than 14 orders of magnitude. One technique employed to reduce the laser frequency noise will be arm locking, where the laser frequency is locked to the LISA arm length. In this paper we detail an implementation of arm locking. We investigate orbital effects (changing arm lengths and Doppler frequencies), the impact of errors in the Doppler knowledge that can cause pulling of the laser frequency, and the noise limit of armmore » locking. Laser frequency pulling is examined in two regimes: at lock acquisition and in steady state. The noise performance of arm locking is calculated with the inclusion of the dominant expected noise sources: ultrastable oscillator (clock) noise, spacecraft motion, and shot noise. We find that clock noise and spacecraft motion limit the performance of dual arm locking in the LISA science band. Studying these issues reveals that although dual arm locking [A. Sutton and D. A. Shaddock, Phys. Rev. D 78, 082001 (2008)] has advantages over single (or common) arm locking in terms of allowing high gain, it has disadvantages in both laser frequency pulling and noise performance. We address this by proposing a modification to the dual arm-locking sensor, a hybrid of common and dual arm-locking sensors. This modified dual arm-locking sensor has the laser frequency pulling characteristics and low-frequency noise coupling of common arm locking, but retains the control system advantages of dual arm locking. We present a detailed design of an arm-locking controller and perform an analysis of the expected performance when used with and without laser prestabilization. We observe that the sensor phase changes beneficially near unity-gain frequencies of the arm-locking controller, allowing a factor of 10 more gain than previously believed, without degrading stability. With a time-delay error of 3 ns (equivalent of 1 m interspacecraft ranging error), time-delay interferometry (TDI) is capable of suppressing 300 Hz/{radical}(Hz) of laser frequency noise to the required level. We show that if no interspacecraft laser links fail, arm locking alone surpasses this noise performance for the entire mission. If one interspacecraft laser link fails, arm locking alone will achieve this performance for all but approximately 1 h per year, when the arm length mismatch of the two remaining arms passes through zero. Therefore, the LISA sensitivity can be realized with arm locking and time-delay interferometry only, without any form of prestabilization.« less
26 CFR 48.4217-2 - Limitation on amount of tax applicable to certain leases.
Code of Federal Regulations, 2010 CFR
2010-04-01
... engaged in the business of selling in arm's length transactions the same type and model of an article as... an article only if, at the time of making the lease, the lessor is engaged in the business of selling in arm's length transactions the same type and model of article. In case of a lease to which section...
Kilaru, Austin S; Perrone, Jeanmarie; Auriemma, Catherine L; Shofer, Frances S; Barg, Frances K; Meisel, Zachary F
2014-03-01
Physicians adopt evidence-based guidelines with variable consistency. Narratives, or stories, offer a novel dissemination strategy for clinical recommendations. The study objective was to compare whether evidence-based narrative versus traditional summary improved recall of opioid prescribing guidelines from the American College of Emergency Physicians (ACEP). This was a prospective, randomized controlled experiment to compare whether narrative versus summary promoted short-term recall of six themes contained in the ACEP opioid guideline. The experiment was modeled after the free-recall test, an established technique in studies of memory. At a regional conference, emergency physicians (EPs) were randomized to read either a summary of the guideline (control) or a narrative (intervention). The fictional narrative was constructed to match the summary in content and length. One hour after reading the text, participants listed all content that they could recall. Two reviewers independently scored the responses to assess recall of the six themes. The primary outcome was the total number of themes recalled per participant. Secondary outcomes included the proportion of responses in each study arm that recalled individual themes and the proportion of responses in each arm that contained falsely recalled or extraneous information. Ninety-five physicians were randomized. Eighty-two physicians completed the experiment, for a response rate of 86%. The mean of the total number of themes recalled per participant was 3.1 in the narrative arm versus 2.0 in the summary arm (difference = 1.1, 95% confidence interval [CI] = 0.6 to 1.7). For three themes, the proportion of responses that recalled the theme was significantly greater in the narrative arm compared to the summary arm, with the differences ranging from 20% to 51%. For one theme, recall was significantly greater in the summary arm. For two themes, there was no statistically significant difference in recall between the arms. In the summary arm, 54% of responses were found to contain falsely recalled or extraneous information versus 21% of responses in the narrative arm (difference = 33%, 95% CI = 14% to 53%). Physicians exposed to a narrative about opioid guidelines were more likely to recall guideline content at 1 hour than those exposed to a summary of the guidelines. Future studies should examine whether the incorporation of narratives in dissemination campaigns improves guideline adoption and changes clinical practice
Kilaru, Austin S.; Perrone, Jeanmarie; Auriemma, Catherine L.; Shofer, Frances S.; Barg, Frances K.; Meisel, Zachary F.
2014-01-01
Objectives Physicians adopt evidence-based guidelines with variable consistency. Narratives, or stories, offer a novel dissemination strategy for clinical recommendations. The study objective was to compare whether evidence-based narrative versus traditional summary improved recall of opioid prescribing guidelines from the American College of Emergency Physicians (ACEP). Methods This was a prospective, randomized controlled experiment to compare whether narrative versus summary promoted short-term recall of six themes contained in the ACEP opioid guideline. The experiment was modeled after the free-recall test, an established technique in studies of memory. At a regional conference, emergency physicians were randomized to read either a summary of the guideline (control) or a narrative (intervention). The fictional narrative was constructed to match the summary in content and length. One hour after reading the text, participants listed all content that they could recall. Two reviewers independently scored the responses to assess recall of the six themes. The primary outcome was the total number of themes recalled per participant. Secondary outcomes included the proportion of responses in each study arm that recalled individual themes and the proportion of responses in each arm that contained falsely recalled or extraneous information. Results Ninety-five physicians were randomized. Eighty-two physicians completed the experiment, for a response rate of 86%. The mean of the total number of themes recalled per participant was 3.1 in the narrative arm versus 2.0 in the summary arm (difference = 1.1, 95% confidence interval [CI] = 0.6 to 1.7). For three themes, the proportion of responses that recalled the theme was significantly greater in the narrative arm compared to the summary arm, with the differences ranging from 20% to 51%. For one theme, recall was significantly greater in the summary arm. For two themes, there was no statistically significant difference in recall between the arms. In the summary arm, 54% of responses were found to contain falsely recalled or extraneous information versus 21% of responses in the narrative arm (difference = 33%, 95% CI = 14% to 53%). Conclusions Physicians exposed to a narrative about opioid guidelines were more likely to recall guideline content at 1 hour than those exposed to a summary of the guidelines. Future studies should examine whether the incorporation of narratives in dissemination campaigns improves guideline adoption and changes clinical practice. PMID:24761456
Billah, Sk Masum; Ferdous, Tarana E; Karim, Mohd Anisul; Dibley, Michael J; Raihana, Shahreen; Moinuddin, Md; Choudhury, Nuzhat; Ahmed, Tahmeed; Hoque, D M Emdadul; Menon, Purnima; Arifeen, Shams El
2017-05-02
Prevalence of stunting among under-five children in Bangladesh is 36%, varying with geographic and socio-economic characteristics. Previously, research groups statistically modelled the effect of 10 individual nutrition-specific interventions targeting the critical first 1000 days of life from conception, on lives saved and costs incurred in countries with the highest burden of stunted children. However, primary research on the combined effects of these interventions is limited. Our study directly addresses this gap by examining the effect of combinations of 5 preventive interventions on length-for-age z-scores (LAZ) among 2-years old children. This community-based cluster randomised trial (c-RCT) compares 4 intervention combinations against one comparison arm. Intervention combinations are: 1) Behaviour change communication (BCC) on maternal nutrition during pregnancy, exclusive breastfeeding, and complementary feeding, along with prenatal nutritional supplement (PNS) and complementary food supplement (CFS); 2) BCC with PNS; 3) BCC with CFS; and 4) BCC alone. The comparison arm receives only routine health and nutrition services. From a rural district, 125 clusters were selected and randomly assigned to any one of the five study arms by block randomisation. A bespoke automated tab-based system was developed linking data collection, intervention delivery and project supervision. Total sample size is 1500 pregnant women, with minimum 1050 resultant children expected to be retained, powered to detect a difference of at least 0.4 in the mean LAZ score of children at 24 months, the main outcome variable, between the comparison arm and each intervention arm. Length and other anthropometric measurements, nutritional intake and other relevant data on mother and children are being collected during enrolment, twice during pregnancy, postpartum monthly till 6 months, and every third month thereafter till 24 months. This c-RCT explores the effectiveness of bundles of preventive nutrition intervention approaches addressing the critical window of opportunity to mitigate childhood stunting. The results will provide robust evidence as to which bundle(s) can have significant effect on linear growth of children. Our study also will have policy-level implications for prioritising intervention(s) tackling stunting. The study was retrospectively registered on May 2, 2016 and is available online at ClinicalTrials.gov (ID: NCT02768181 ).
DoD Task Force to Improve Industrial Responsiveness.
1982-03-01
more elements of the Improvement Triad. The directives and other documents revised or developed, and their relationship to the Improvement Triad, is...2010.6, reference (e)) 8. Although a proper arms-length business relationship with industry must be maintained in order to protect the public interest...and to foster competi- tion, a strong industrial base is necessary for a strong defense. The proper arms-length buyer-seller relationship should not
Model-based sensorimotor integration for multi-joint control: development of a virtual arm model.
Song, D; Lan, N; Loeb, G E; Gordon, J
2008-06-01
An integrated, sensorimotor virtual arm (VA) model has been developed and validated for simulation studies of control of human arm movements. Realistic anatomical features of shoulder, elbow and forearm joints were captured with a graphic modeling environment, SIMM. The model included 15 musculotendon elements acting at the shoulder, elbow and forearm. Muscle actions on joints were evaluated by SIMM generated moment arms that were matched to experimentally measured profiles. The Virtual Muscle (VM) model contained appropriate admixture of slow and fast twitch fibers with realistic physiological properties for force production. A realistic spindle model was embedded in each VM with inputs of fascicle length, gamma static (gamma(stat)) and dynamic (gamma(dyn)) controls and outputs of primary (I(a)) and secondary (II) afferents. A piecewise linear model of Golgi Tendon Organ (GTO) represented the ensemble sampling (I(b)) of the total muscle force at the tendon. All model components were integrated into a Simulink block using a special software tool. The complete VA model was validated with open-loop simulation at discrete hand positions within the full range of alpha and gamma drives to extrafusal and intrafusal muscle fibers. The model behaviors were consistent with a wide variety of physiological phenomena. Spindle afferents were effectively modulated by fusimotor drives and hand positions of the arm. These simulations validated the VA model as a computational tool for studying arm movement control. The VA model is available to researchers at website http://pt.usc.edu/cel .
Anthropometry as a predictor of vertical jump heights derived from an instrumented platform.
Caruso, John F; Daily, Jeremy S; Mason, Melissa L; Shepherd, Catherine M; McLagan, Jessica R; Marshall, Mallory R; Walker, Ron H; West, Jason O
2012-01-01
The current study purpose examined the vertical height-anthropometry relationship with jump data obtained from an instrumented platform. Our methods required college-aged (n = 177) subjects to make 3 visits to our laboratory to measure the following anthropometric variables: height, body mass, upper arm length (UAL), lower arm length, upper leg length, and lower leg length. Per jump, maximum height was measured in 3 ways: from the subjects' takeoff, hang times, and as they landed on the platform. Standard multivariate regression assessed how well anthropometry predicted the criterion variance per gender (men, women, pooled) and jump height method (takeoff, hang time, landing) combination. Z-scores indicated that small amounts of the total data were outliers. The results showed that the majority of outliers were from jump heights calculated as women landed on the platform. With the genders pooled, anthropometry predicted a significant (p < 0.05) amount of variance from jump heights calculated from both takeoff and hang time. The anthropometry-vertical jump relationship was not significant from heights calculated as subjects landed on the platform, likely due to the female outliers. Yet anthropometric data of men did predict a significant amount of variance from heights calculated when they landed on the platform; univariate correlations of men's data revealed that UAL was the best predictor. It was concluded that the large sample of men's data led to greater data heterogeneity and a higher univariate correlation. Because of our sample size and data heterogeneity, practical applications suggest that coaches may find our results best predict performance for a variety of college-aged athletes and vertical jump enthusiasts.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., from the property where it is produced to the point where you or your affiliate purchase(s) it. You may..., for purchases or sales under arm's-length contracts. (1) When calculating that unit value, use only purchases or sales of other like-quality oil produced from the field (or the same area if you do not have...
Andereck, William S; McGaughey, J Westly; Schneiderman, Lawrence J; Jonsen, Albert R
2014-04-01
To investigate whether the proactive intervention of a clinical ethicist in cases of prolonged lengths of stay in a critical care setting reduces nonbeneficial treatment while increasing perceived patient/surrogate and provider satisfaction and reducing associated costs. Nonbeneficial treatment is defined here as the use of life-sustaining treatments delivered to patients who had been in the ICU for 5 days and did not survive to discharge. Prospective randomized exploratory trial from October 2007 to February 2010 in the adult ICU of a large, urban, not-for-profit community hospital. Medical/surgical ICU of California Pacific Medical Center, a large tertiary not-for-profit hospital in San Francisco, CA. Three hundred eighty-four patients with ICU lengths of stay of five days or greater. Patients were randomized to either an intervention arm (Proactive Ethics Intervention) (n = 174) or control arm (n = 210). There were 56 patients in the intervention arm and 52 patients in the control arm who did not survive to discharge. Proactive ethics intervention involves a trained bioethicist in the care of all ICU patients with a length of stay greater than or equal to 5 days. The intervention used a nine step process model designed to look for manifest or latent ethics conflicts and address them. The primary outcome measures were days in the ICU; overall length of hospital stay; mortality; nonbeneficial treatments, for example, provision of nutritional support; surrogate and survivor satisfaction, and cost. The intervention and control arms showed no significant difference in mortality. Proactive Ethics Intervention, at the 95% CI, was not associated with reductions of overall length of stay (23 d for intervention and 21 d for control, p = 0.74), ICU days (11 in each arm, p = 0.91), life-sustaining treatments (days on ventilator: intervention, 14.6; control, 13.7; p = 0.74; days receiving artificial nutrition and hydration: intervention, 16.5; control, 15.9; p = 0.85), or cost ($167,350.00 for intervention and $164,670.00 for control, p =0.92) in patients who did not survive to discharge. Perceptions of quality of care by patients and providers showed no difference between intervention and control arms. Our study finds that Proactive Ethics Intervention, provided to all patients in a critical care setting for 5 days, and before an ethical conflict has been recognized, is ineffective in reducing overall length of hospital stay, ICU days, nonbeneficial treatments, or hospital costs. It is also not effective in increasing perceptions of quality of care by patients or providers.
Henninger, Heath B; King, Frank K; Tashjian, Robert Z; Burks, Robert T
2014-05-01
Numerous studies have examined the biomechanics of isolated variables in reverse total shoulder arthroplasty. This study directly compared the composite performance of two reverse total shoulder arthroplasty systems; each system was designed around either a medialized or a lateralized glenohumeral center of rotation. Seven pairs of shoulders were tested on a biomechanical simulator. Center of rotation, position of the humerus, passive and active range of motion, and force to abduct the arm were quantified. Native arms were tested, implanted with a Tornier Aequalis or DJO Surgical Reverse Shoulder Prosthesis (RSP), and then retested. Differences from the native state were then documented. Both systems shifted the center of rotation medially and inferiorly relative to native. Medial shifts were greater in the Aequalis implant (P < .037). All humeri shifted inferior compared with native but moved medially with the Aequalis (P < .001). Peak passive abduction, internal rotation, and external rotation did not differ between systems (P > .05). Both reverse total shoulder arthroplasty systems exhibited adduction deficits, but the RSP implant deficit was smaller (P = .046 between implants). Both systems reduced forces to abduct the arm compared with native, although the Aequalis required more force to initiate motion from the resting position (P = .022). Given the differences in system designs and configurations, outcome variables were generally comparable. The RSP implant allowed slightly more adduction, had a more lateralized humeral position, and required less force to initiate elevation. These factors may play roles in limiting scapular notching, improving active external rotation by normalizing the residual rotator cuff length, and limiting excessive stress on the deltoid. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Effects of constrained arm swing on vertical center of mass displacement during walking.
Yang, Hyung Suk; Atkins, Lee T; Jensen, Daniel B; James, C Roger
2015-10-01
The purpose of this study was to determine the effects of constraining arm swing on the vertical displacement of the body's center of mass (COM) during treadmill walking and examine several common gait variables that may account for or mask differences in the body's COM motion with and without arm swing. Participants included 20 healthy individuals (10 male, 10 female; age: 27.8 ± 6.8 years). The body's COM displacement, first and second peak vertical ground reaction forces (VGRFs), and lowest VGRF during mid-stance, peak summed bilateral VGRF, lower extremity sagittal joint angles, stride length, and foot contact time were measured with and without arm swing during walking at 1.34 m/s. The body's COM displacement was greater with the arms constrained (arm swing: 4.1 ± 1.2 cm, arm constrained: 4.9 ± 1.2 cm, p < 0.001). Ground reaction force data indicated that the COM displacement increased in both double limb and single limb stance. However, kinematic patterns visually appeared similar between conditions. Shortened stride length and foot contact time also were observed, although these do not seem to account for the increased COM displacement. However, a change in arm COM acceleration might have contributed to the difference. These findings indicate that a change in arm swing causes differences in vertical COM displacement, which could increase energy expenditure. Copyright © 2015 Elsevier B.V. All rights reserved.
Calcaneotalar ratio: a new concept in the estimation of the length of the calcaneus.
David, Vikram; Stephens, Terry J; Kindl, Radek; Ang, Andy; Tay, Wei-Han; Asaid, Rafik; McCullough, Keith
2015-01-01
Maintaining the calcaneal length after calcaneal fractures is vital to restoring the normal biomechanics of the foot, because it acts as an important lever arm to the plantarflexors of the foot. However, estimation of the length of the calcaneus to be reconstructed in comminuted calcaneal fractures can be difficult. We propose a new method to reliably estimate the calcaneal length radiographically by defining the calcaneotalar length ratio. A total of 100 ankle radiographs with no fracture in the calcaneus or talus taken in skeletally mature patients were reviewed by 6 observers. The anteroposterior lengths of the calcaneus and talus were measured, and the calcaneotalar length ratio was determined. The ratio was then used to estimate the length of the calcaneus. Interobserver reliability was determined using Cronbach's α coefficient and Pearson's correlation coefficient. The mean length of the calcaneus was 75 ± 0.6 mm, and the mean length of the talus was 59 ± 0.5 mm. The calcaneotalar ratio was 1.3. Using this ratio and multiplying it by the talar length, the mean average estimated length of the calcaneus was within 0.7 mm of the known calcaneal length. Cronbach's α coefficient and Pearson's correlation coefficient showed excellent interobserver reliability. The proposed calcaneotalar ratio is a new and reliable method to radiographically estimate the normal length of the calcaneus when reconstructing the calcaneus. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Thompson, Elizabeth; Agada, Peter; Wright, W Geoffrey; Reimann, Hendrik; Jeka, John
2017-10-01
Impaired arm swing is a common motor symptom of Parkinson's disease (PD), and correlates with other gait impairments and increased risk of falls. Studies suggest that arm swing is not merely a passive consequence of trunk rotation during walking, but an active component of gait. Thus, techniques to enhance arm swing may improve gait characteristics. There is currently no portable device to measure arm swing and deliver immediate cues for larger movement. Here we test report pilot testing of such a device, ArmSense (patented), using a crossover repeated-measures design. Twelve people with PD walked in a video-recorded gym space at self-selected comfortable and fast speeds. After baseline, cues were given either visually using taped targets on the floor to increase step length or through vibrations at the wrist using ArmSense to increase arm swing amplitude. Uncued walking then followed, to assess retention. Subjects successfully reached cueing targets on >95% of steps. At a comfortable pace, step length increased during both visual cueing and ArmSense cueing. However, we observed increased medial-lateral trunk sway with visual cueing, possibly suggesting decreased gait stability. In contrast, no statistically significant changes in trunk sway were observed with ArmSense cues compared to baseline walking. At a fast pace, changes in gait parameters were less systematic. Even though ArmSense cues only specified changes in arm swing amplitude, we observed changes in multiple gait parameters, reflecting the active role arm swing plays in gait and suggesting a new therapeutic path to improve mobility in people with PD. Copyright © 2017 Elsevier B.V. All rights reserved.
Technique of Axillary Use of a Combat Ready Clamp to Stop Junctional Bleeding
2013-01-01
compressed parallel to—but not on—the clavicle (Fig. 4). 5. Adjust the horizontal arm length by using its locking pin. 6. Adjust the vertical arm by...arm adjustment for square disk head contact atop the target. Fig. 4. Placing the square disk head atop the target, parallel to—but not on—the clavicle
Regulatory light chain mutants linked to heart disease modify the cardiac myosin lever arm.
Burghardt, Thomas P; Sikkink, Laura A
2013-02-19
Myosin is the chemomechanical energy transducer in striated heart muscle. The myosin cross-bridge applies impulsive force to actin while consuming ATP chemical energy to propel myosin thick filaments relative to actin thin filaments in the fiber. Transduction begins with ATP hydrolysis in the cross-bridge driving rotary movement of a lever arm converting torque into linear displacement. Myosin regulatory light chain (RLC) binds to the lever arm and modifies its ability to translate actin. Gene sequencing implicated several RLC mutations in heart disease, and three of them are investigated here using photoactivatable GFP-tagged RLC (RLC-PAGFP) exchanged into permeabilized papillary muscle fibers. A single-lever arm probe orientation is detected in the crowded environment of the muscle fiber by using RLC-PAGFP with dipole orientation deduced from the three-spatial dimension fluorescence emission pattern of the single molecule. Symmetry and selection rules locate dipoles in their half-sarcomere, identify those at the minimal free energy, and specify active dipole contraction intermediates. Experiments were performed in a microfluidic chamber designed for isometric contraction, total internal reflection fluorescence detection, and two-photon excitation second harmonic generation to evaluate sarcomere length. The RLC-PAGFP reports apparently discretized lever arm orientation intermediates in active isometric fibers that on average produce the stall force. Disease-linked mutants introduced into RLC move intermediate occupancy further down the free energy gradient, implying lever arms rotate more to reach stall force because mutant RLC increases lever arm shear strain. A lower free energy intermediate occupancy involves a lower energy conversion efficiency in the fiber relating a specific myosin function modification to the disease-implicated mutant.
Sim, Kang Hee; Hwang, Moon Sook; Kim, Sun Young; Lee, Hye Mi; Chang, Ji Yeun; Lee, Moon Kyu
2014-04-01
Longer needle and complicated insulin injection technique such as injecting at a 45-degree angle and making skinfolds may decrease patient compliance to insulin injection therapy. In this light, shorter insulin needles have been recently developed. However, it is necessary to ascertain that such shorter needles are appropriate for Korean patients with diabetes as well. First, the diverse demographic and diabetic features of 156 Korean adults with diabetes were collected by a questionnaire and a device unit of body fat measurement. The skin and subcutaneous fat thicknesses of each subject were measured by Ultrasound device with a 7- to 12-MHz probe. Data were analyzed using analysis of variance and multiple linear regression. The mean skin thickness was 2.29±0.37 mm in the abdomen and 2.00±0.34 mm in the upper arms, and the mean subcutaneous fat thickness was to 10.15±6.54 mm in the abdomen and 5.50±2.68 mm in the upper arms. Our analysis showed that the factors affecting the skin thickness of the abdomen and upper arms were gender and body mass index (BMI), whereas the factors influencing the subcutaneous fat thickness in the abdomen were gender and BMI, and the factors influencing the subcutaneous fat thickness in the upper arms were gender, BMI, and age. Insulin fluids may not appear to be intradermally injected into the abdomen and upper arms at any needle lengths. The risk of intramuscular injection is likely to increase with longer insulin needles and lower BMI. It is recommended to fully inform the patients about the lengths of needles for insulin injections. As for the recommended needle length, the findings of this study indicate that needles as short as 4 mm are sufficient to deliver insulin for Korean patients with diabetes.
Sim, Kang Hee; Kim, Sun Young; Lee, Hye Mi; Chang, Ji Yeun; Lee, Moon Kyu
2014-01-01
Background Longer needle and complicated insulin injection technique such as injecting at a 45-degree angle and making skinfolds may decrease patient compliance to insulin injection therapy. In this light, shorter insulin needles have been recently developed. However, it is necessary to ascertain that such shorter needles are appropriate for Korean patients with diabetes as well. Methods First, the diverse demographic and diabetic features of 156 Korean adults with diabetes were collected by a questionnaire and a device unit of body fat measurement. The skin and subcutaneous fat thicknesses of each subject were measured by Ultrasound device with a 7- to 12-MHz probe. Data were analyzed using analysis of variance and multiple linear regression. Results The mean skin thickness was 2.29±0.37 mm in the abdomen and 2.00±0.34 mm in the upper arms, and the mean subcutaneous fat thickness was to 10.15±6.54 mm in the abdomen and 5.50±2.68 mm in the upper arms. Our analysis showed that the factors affecting the skin thickness of the abdomen and upper arms were gender and body mass index (BMI), whereas the factors influencing the subcutaneous fat thickness in the abdomen were gender and BMI, and the factors influencing the subcutaneous fat thickness in the upper arms were gender, BMI, and age. Insulin fluids may not appear to be intradermally injected into the abdomen and upper arms at any needle lengths. The risk of intramuscular injection is likely to increase with longer insulin needles and lower BMI. Conclusion It is recommended to fully inform the patients about the lengths of needles for insulin injections. As for the recommended needle length, the findings of this study indicate that needles as short as 4 mm are sufficient to deliver insulin for Korean patients with diabetes. PMID:24851206
Magnetically Suspended Linear Pulse Motor for Semiconductor Wafer Transfer in Vacuum Chamber
NASA Technical Reports Server (NTRS)
Moriyama, Shin-Ichi; Hiraki, Naoji; Watanabe, Katsuhide; Kanemitsu, Yoichi
1996-01-01
This paper describes a magnetically suspended linear pulse motor for a semiconductor wafer transfer robot in a vacuum chamber. The motor can drive a wafer transfer arm horizontally without mechanical contact. In the construction of the magnetic suspension system, four pairs of linear magnetic bearings for the lift control are used for the guidance control as well. This approach allows us to make the whole motor compact in size and light in weight. The tested motor consists of a double-sided stator and a transfer arm with a width of 50 mm and a total length of 700 mm. The arm, like a ladder in shape, is designed as the floating element with a tooth width of 4 mm (a tooth pitch of 8 mm). The mover mass is limited to about 1.6 kg by adopting such an arm structure, and the ratio of thrust to mover mass reaches to 3.2 N/kg under a broad air gap (1 mm) between the stator teeth and the mover teeth. The performance testing was carried out with a transfer distance less than 450 mm and a transfer speed less than 560 mm/s. The attitude of the arm was well controlled by the linear magnetic bearings with a combined use, and consequently the repeatability on the positioning of the arm reached to about 2 micron. In addition, the positioning accuracy was improved up to about 30 micron through a compensation of the 128-step wave current which was used for the micro-step drive with a step increment of 62.5 micron.
House, Gregory; Burdea, Grigore; Grampurohit, Namrata; Polistico, Kevin; Roll, Doru; Damiani, Frank; Hundal, Jasdeep; Demesmin, Didier
2016-01-01
Background: Persistent pain in shoulder and arm following post-surgical breast cancer treatment can lead to cognitive and physical deficits. Depression is also common in breast cancer survivors. Virtual reality therapy with integrative cognitive and physical rehabilitation has not been clinically trialed for this population. The novel BrightArm Duo technology improved cognition and upper extremity (UE) function for other diagnoses and has great potential to benefit individuals coping with post-surgical breast cancer pain. Objectives: The aim of this study was to explore the feasibility of BrightArm Duo therapy for coping with post-surgical chronic pain and associated disability in breast cancer survivors with depression. Methods: BrightArm Duo is a robotic rehabilitation table modulating gravity loading on supported forearms. It tracks arm position and grasping strength while patients play three-dimensional (3D) custom integrative rehabilitation games. Community-dwelling women (N = 6) with post-surgical breast cancer pain in the upper arm trained on the system twice a week for 8 weeks. Training difficulty increased progressively in game complexity, table tilt and session length (20–50 minutes). Standardized assessments were performed before and after therapy for pain, cognition, emotion, UE function and activities of daily living. Results: Subjects averaged upwards of 1300 arm repetitions and 850 hand grasps per session. Pain intensity showed a 20% downward trend (p = 0.1) that was corroborated by therapist observations and participant feedback. A total of 10 out of 11 cognitive metrics improved post-training (p = 0.01) with a significant 8.3-point reduction in depression severity (p = 0.04). A total of 17 of 18 range of motion metrics increased (p < 0.01), with five affected-side shoulder improvements above the Minimal Clinically Important Difference (8°). In all, 13 out of 15 strength and function metrics improved (p = 0.02) with lateral deltoid strength increasing 7.4 N on the affected side (p = 0.05). Conclusion: This pilot study demonstrated feasibility of using the BrightArm Duo Rehabilitation System to treat cancer survivors coping with upper body chronic pain. Outcomes indicate improvement in cognition, shoulder range, strength, function and depression. PMID:27867508
House, Gregory; Burdea, Grigore; Grampurohit, Namrata; Polistico, Kevin; Roll, Doru; Damiani, Frank; Hundal, Jasdeep; Demesmin, Didier
2016-11-01
Persistent pain in shoulder and arm following post-surgical breast cancer treatment can lead to cognitive and physical deficits. Depression is also common in breast cancer survivors. Virtual reality therapy with integrative cognitive and physical rehabilitation has not been clinically trialed for this population. The novel BrightArm Duo technology improved cognition and upper extremity (UE) function for other diagnoses and has great potential to benefit individuals coping with post-surgical breast cancer pain. The aim of this study was to explore the feasibility of BrightArm Duo therapy for coping with post-surgical chronic pain and associated disability in breast cancer survivors with depression. BrightArm Duo is a robotic rehabilitation table modulating gravity loading on supported forearms. It tracks arm position and grasping strength while patients play three-dimensional (3D) custom integrative rehabilitation games. Community-dwelling women (N = 6) with post-surgical breast cancer pain in the upper arm trained on the system twice a week for 8 weeks. Training difficulty increased progressively in game complexity, table tilt and session length (20-50 minutes). Standardized assessments were performed before and after therapy for pain, cognition, emotion, UE function and activities of daily living. Subjects averaged upwards of 1300 arm repetitions and 850 hand grasps per session. Pain intensity showed a 20% downward trend (p = 0.1) that was corroborated by therapist observations and participant feedback. A total of 10 out of 11 cognitive metrics improved post-training (p = 0.01) with a significant 8.3-point reduction in depression severity (p = 0.04). A total of 17 of 18 range of motion metrics increased (p < 0.01), with five affected-side shoulder improvements above the Minimal Clinically Important Difference (8°). In all, 13 out of 15 strength and function metrics improved (p = 0.02) with lateral deltoid strength increasing 7.4 N on the affected side (p = 0.05). This pilot study demonstrated feasibility of using the BrightArm Duo Rehabilitation System to treat cancer survivors coping with upper body chronic pain. Outcomes indicate improvement in cognition, shoulder range, strength, function and depression.
Thumb rule of visual angle: a new confirmation.
Groot, C; Ortega, F; Beltran, F S
1994-02-01
The classical thumb rule of visual angle was reexamined. Hence, the visual angle was measured as a function of a thumb's width and the distance between eye and thumb. The measurement of a thumb's width when held at arm's length was taken on 67 second-year students of psychology. The visual angle was about 2 degrees as R. P. O'Shea confirmed in 1991. Also, we confirmed a linear relationship between the size of a thumb's width at arm's length and the visual angle.
The Arts and State Governments: At Arm's Length or Arm in Arm?
ERIC Educational Resources Information Center
Lowell, Julia F.; Ondaatje, Elizabeth Heneghan
2006-01-01
Even though a majority of Americans claim to support public funding of the arts, state government spending on the arts is minimal--and may be losing ground relative to other types of state expenditures. Moreover, most state arts agencies, or SAAs, have not succeeded in convincing state government leaders that the arts should be integral to their…
NASA Astrophysics Data System (ADS)
Keypour, Hassan; Shayesteh, Maryam; Rezaeivala, Majid; Dhers, Sébastien; Küp, Fatma Öztürk; Güllü, Mithat; Ng, Seikweng
2017-11-01
The synthesis of two unsymmetrical N-capped tripodal amines, 2-((4-aminobutyl)(pyridin-2-ylmethyl)amino)ethanol (3) and 3-((2-aminoethyl)(pyridin-2-ylmethyl)amino)propan-1-ol (4) is reported. They feature a longer, 3-hydroxypropyl or butylamino arm than that in the analogues previously employed. All four tripodal amines, 1-4, are equipped with a 2-methylpyridyl-arm, and either an ethylamino-arm (1 and 4), propylamino-arm (2) or butylamino-arm (3). The amines, 3 and 4, have been employed in one pot condensation reactions with salicylaldehyde and its derivatives in the presence of Ni(II) metal ion. A series of new mononuclear complexes, [NiIILaldi](ClO4) or [NiIILaldi(solvent)](ClO4) with different geometry, of Schiff base ligands were generated. X-ray crystal structure determinations of [NiIILOMe3(H2O)](ClO4)·2H2O and [NiIILOMe4](ClO4) revealed them to be mononuclear. The Ni(II) ion in [NiIILOMe4](ClO4) complex is in a distorted square-planar environment whilst this ion is in distorted octahedral environment in [NiIILOMe3(H2O)](ClO4)·2H2O complex despite the longer arm length of L3. While, in related systems in our previous work, they had led to dimeric complexes. These results clearly showed that the variation of the arm lengths of the ligands and metal ions has a remarkable impact on the formation and structure of the complexes. The cleavage of DNA by all synthesised complexes was examined using gel electrophoresis experiments. Also, the antibacterial effects of components were determined against the three Gram-positive bacteria, and against the three Gram-negative bacteria and against the three yeast Candida albicans ATCC 10231, Candida krusei ATCC 1424 and Candida tropicalis ATCC 13803.
Robotic-Movement Payload Lifter and Manipulator
NASA Technical Reports Server (NTRS)
Doggett, William R. (Inventor); King, Bruce D. (Inventor); Collins, Timothy J. (Inventor); Dorsey, John T. (Inventor)
2011-01-01
A payload lifter/manipulator module includes a rotatable joint supporting spreader arms angularly spaced with respect to one another. A rigid arm is fixedly coupled to the joint and extends out therefrom to a tip. A tension arm has a first end and a second end with the first end being fixedly coupled to the tip of the rigid arm. The tension arm incorporates pivots along the length thereof. Each pivot can be engaged by or disengaged from the outboard end of a spreader arm based on a position of the spreader arm. A hoist, positioned remotely with respect to the module and coupled to the second end of the tension arm, controls the position of the spreader arms to thereby control the position of the rigid arm's tip. Payload lifter/manipulator assemblies can be constructed with one or more of the modules.
Butz, Sarah M; Sweeney, Jane K; Roberts, Pamela L; Rauh, Mitchell J
2015-01-01
To examine relationships among age, gender, anthropometrics, and dynamic balance. Height, weight, and arm and foot length were measured in 160 children with typical development aged 5 to 12 years. Dynamic balance was assessed using the Timed Up and Go (TUG) test, Pediatric Reach Test (PRT), and Pediatric Balance Scale (PBS). Moderate to good positive relationships (r = 0.61 and r = 0.56) were found between increasing age and PRT and PBS scores. A fair negative relationship (r = -0.49) was observed between age and TUG test. No significant gender-by-age group difference was observed. Age had the strongest influence on TUG and PBS scores; arm length had the strongest influence on PRT scores. Dynamic balance ability is directly related to chronological age. Age and arm length have the strongest relationships with balance scores. These findings may assist pediatric therapists in selecting dynamic balance tests according to age rather than specific diagnosis.
Anthropometry as a predictor of bench press performance done at different loads.
Caruso, John F; Taylor, Skyler T; Lutz, Brant M; Olson, Nathan M; Mason, Melissa L; Borgsmiller, Jake A; Riner, Rebekah D
2012-09-01
The purpose of our study was to examine the ability of anthropometric variables (body mass, total arm length, biacromial width) to predict bench press performance at both maximal and submaximal loads. Our methods required 36 men to visit our laboratory and submit to anthropometric measurements, followed by lifting as much weight as possible in good form one time (1 repetition maximum, 1RM) in the exercise. They made 3 more visits in which they performed 4 sets of bench presses to volitional failure at 1 of 3 (40, 55, or 75% 1RM) submaximal loads. An accelerometer (Myotest Inc., Royal Oak MI) measured peak force, velocity, and power after each submaximal load set. With stepwise multivariate regression, our 3 anthropometric variables attempted to explain significant amounts of variance for 13 bench press performance indices. For criterion measures that reached significance, separate Pearson product moment correlation coefficients further assessed if the strength of association each anthropometric variable had with the criterion was also significant. Our analyses showed that anthropometry explained significant amounts (p < 0.05) of variance for 8 criterion measures. It was concluded that body mass had strong univariate correlations with 1RM and force-related measures, total arm length was moderately associated with 1RM and criterion variables at the lightest load, whereas biacromial width had an inverse relationship with the peak number of repetitions performed per set at the 2 lighter loads. Practical applications suggest results may help coaches and practitioners identify anthropometric features that may best predict various measures of bench press prowess in athletes.
Application of robotics in general surgery: initial experience.
Nguyen, Ninh T; Hinojosa, Marcelo W; Finley, David; Stevens, Melinda; Paya, Mahbod
2004-10-01
Robotic surgery was recently approved for clinical use in general abdominal surgery. The aim of this study was to review our experience with the da Vinci surgical system during laparoscopic general surgical procedures. Eighteen patients underwent robotically assisted laparoscopic abdominal surgery between June 2002 and March 2003. Main outcome measures were operative time, room setup time, robotic arm-positioning and surgical time, blood loss, conversion to laparoscopy, length of stay, and morbidity. The types of robotically assisted laparoscopic procedures were excision of gastric leiomyoma (n = 1), Heller myotomy (n = 1), cholecystectomy (n = 2), gastric banding (n = 2), Nissen fundoplication (n = 4), and gastric bypass (n = 8). The mean room setup time was 63 +/- 14 minutes, and the mean robotic arm-positioning time was 16 +/- 7 minutes. Conversion to laparoscopy occurred in two (11%) of 18 cases because of equipment difficulty (n = 1) and technical difficulty (n = 1). Estimated blood loss was 91 +/- 71 mL. The mean operative time was 156 +/- 42 minutes, and the robotic operative time was 27% of the total operative time. The mean length of hospital stay was 2.2 +/- 1.5 days. There was one postoperative wound infection and one anastomotic stricture. Robotically assisted laparoscopic abdominal surgery is feasible and safe; however, the theoretical advantages of the da Vinci surgical system were not clinically apparent.
A wide angle low coherence interferometry based eye length optometer
NASA Astrophysics Data System (ADS)
Meadway, Alexander; Siegwart, John; Wildsoet, Christine; Norton, Thomas; Zhang, Yuhua
2015-03-01
Interest in eye growth regulation has burgeoned with the rise in myopia prevalence world-wide. Eye length and eye shape are fundamental metrics for related research, but current in vivo measurement techniques are generally limited to the optical axis of the eye. We describe a high resolution, time domain low coherence interferometry based optometer for measuring the eye length of small animals over a wide field of view. The system is based upon a Michelson interferometer using a superluminescent diode as a source, including a sample arm and a reference arm. The sample arm is split into two paths by a polarisation beam splitter; one focuses the light on the cornea and the other focuses the light on the retina. This method has a high efficiency of detection for reflections from both surfaces. The reference arm contains a custom high speed linear motor with 25 mm stroke and equipped with a precision displacement encoder. Light reflected from the cornea and the retina is combined with the reference beam to generate low coherence interferograms. Two galvo scanners are employed to steer the light to different angles so that the eye length over a field of view of 20° × 20° can be measured. The system has an axial resolution of 6.8 μm (in air) and the motor provides accurate movement, allowing for precise and repeatable measurement of coherence peak positions. Example scans from a tree shrew are presented.
Detailed view of one (1) arm of the swing bridge ...
Detailed view of one (1) arm of the swing bridge cantilevering out from the center/pivot pier on which the entire span is balanced at its center when in the open position. Both arms of the span have equal length. Note that the members are pin-connected at their connections (joints). - Bridgeport Swing Span Bridge, Spanning Tennessee River, Bridgeport, Jackson County, AL
Three-disk microswimmer in a supported fluid membrane
NASA Astrophysics Data System (ADS)
Ota, Yui; Hosaka, Yuto; Yasuda, Kento; Komura, Shigeyuki
2018-05-01
A model of three-disk micromachine swimming in a quasi-two-dimensional supported membrane is proposed. We calculate the average swimming velocity as a function of the disk size and the arm length. Due to the presence of the hydrodynamic screening length in the quasi-two-dimensional fluid, the geometric factor appearing in the average velocity exhibits three different asymptotic behaviors depending on the microswimmer size and the hydrodynamic screening length. This is in sharp contrast with a microswimmer in a three-dimensional bulk fluid that shows only a single scaling behavior. We also find that the maximum velocity is obtained when the disks are equal-sized, whereas it is minimized when the average arm lengths are identical. The intrinsic drag of the disks on the substrate does not alter the scaling behaviors of the geometric factor.
Generational changes in the growth of children from Maribor and Slovenia.
Bigec, Martin
2013-05-01
Among the numerous factors which influence a child's growth and development are also factors of changeable socio-economic environment and life style. Our aim was to evaluate these changes and contribute to preventive measures and evaluation of a child's growth in pediatric practice. Therefore, we decided to estimate the state of body growth in two generations of children from Maribor at five and six years of age of both gender, establish secular changes and define standards. On a representative sample (gender and age) of 1461 children from Maribor measured in 1996 and a sample of 608 children from Maribor, measured in 1966, 28 body features were studied and compared in each population unit. Variables were statistically and epidemiologically assessed and results were controlled by a test. The following anthropometric differences were significant: in 5-year old boys the measures in the 1996 generation are statistically higher than in 1966 - foot length, head length, upper arm skinfold, subscapular skinfold, arm length, arm diameter, upper thigh skinfold, stature (length), suprailiac skinfold, and body weight. Decreased measures are: abdomen circumference, knee circumference, sitting height, elbow circumference, biacromial diameter, and face heigth. In 6-year old boys additional features have increased in comparison with the year 1966: sternal height, tight circumference, hip width, chest circumference; following measures have decreased: face height, head circumference. In 5-year old girls: increased measures in comparison with the generation from 1966 are: lower leg length, head length, ankle circumference, upper arm skinfold, body weight, billiac diameter, body height, subscapular skinfold, chest circumference, hip circumference, sternal height, suprailiac skinfold, decreased measures are: head circumference, elbow circumference, face circumference, shoulder with, sitting height. In 6-year old girls additional measures are increased: wrist circumference, arm length and chest circumference. Changing trends show an increased tendency towards decrease or increase of most body measurements. In everyday practice the most commonly used measurements are: body mass, head circumference, body length in babies and body height in pre-school children. Our measurements proved, with a p-value of 0.001, that measurements of children in 1966, also shown in diagrams, are significantly different from measurements in 1996. In the second part of this paper we present a part of the anthropometric measurement study carried out for the standardization of the DENVER II developmental screening test. There were 1596 healthy Slovene children between zero and six and half years of age included into the observation. Children come from Maribor, Koper, Velenje and Ljubljana. We used the Cameron's measurement and statistical method. Diagrams were made for following body measures: body mass, body height, head circumference, upper arm circumference, thigh circumference and body mass index. A comparative analysis with the Euro-Growth study showed that our results correspond with the European standards. Therefore, our results are suggested to be applied in everyday pediatric practice.
Kulathinal, Sangita; Freese, Riitta; Korkalo, Liisa; Ismael, Carina; Mutanen, Marja
2016-08-01
Biochemically determined nutritional status measurements in low-income countries are often too expensive. Therefore, we hypothesized that some anthropometrical or functional measurements (handgrip) could reflect nutritional status measured by specific biochemical indicators. We did a population-based study from 1 urban area and 2 rural districts in Zambézia Province of Mozambique. The participants (n=386) were non-pregnant adolescent girls between 15 and 18 years of age. 96% had a normal BMI-for-age score. Weight and mid-upper arm circumference (MUAC) were highly correlated (r>0.8) with each other and with total body muscle mass, body mass index (BMI), and with waist circumference, as well as with skinfolds (r>0.6). Upper and total arm lengths were correlated (r>0.7) with height and with each other, and right and left handgrip were correlated only with each other, as were triceps and subscapular skinfolds (r>0.7). Serum albumin correlated negatively with waist circumference (P<.001) and positively with MUAC (P=.007). Stepwise regressions showed that waist circumference, MUAC, weight, and handgrip were important nutritional status indicators in the models using hemoglobin, serum albumin, ferritin, zinc, and plasma retinol concentrations as dependent variables. MUAC could be a valuable anthropometric marker of the overall nutritional status of adolescent girls in low-income countries. When nutrition transition proceeds, waist circumference together with MUAC could form tools for the prediction of worsening of nutritional status. Copyright © 2016 Elsevier Inc. All rights reserved.
Totonchi, Samer; Elgin, Robert; Monahan, Michael; Johnston, William K
2014-08-01
Abstract Background and Purpose: Placement of the fourth arm (4th arm) in the lower quadrant (LQ) is commonly described for robot-assisted renal surgical procedures but has anatomic restrictions and limited ergonomics. An alternative, upper quadrant (UQ) location is desirable, but patient habitus and spacing may restrict robotic attachment. We investigate current trends in 4th arm port placement and propose an alternative method at attaching the robot-the "Floating Arm" (FLA). Robotic surgeons from the Endourological Society were surveyed. A 20-cm extra-long (XL Protype) da Vinci instrument was developed for the FLA technique. A dry lab allowed quantitative comparison of spacing and ranges of motion for standard da Vinci ports (dVP), bariatric dVP, telescoping dVP, and FLA. There were 108 respondents who participated. Half of the respondents avoid using the 4th arm (30% lack of need and 20% because of interference). The majority (90%) typically positions the 4th arm in the LQ, but many reported limitations in this location. Few (5%) place 4th arm in the UQ, while most (73%) have never heard of UQ placement. Existing techniques may increase shoulder height clearance but inversely shorten the working length of the instrument intracorporeally. Alternatively, the XL Protype significantly increased the shoulder length and maintained available working distances intracorporeally. Adjacent arm interference angle was essentially identical (27 degrees) for all ports except a greater range of movement for the XL Protype (35 degrees). Few surgeons are using an UQ positioning or use techniques to improve attachment of the 4th arm. The greatest freedom may be obtained by implementing the FLA, but this necessitates production of a longer instrument.
The Effects of Unit Exercises on the Hand Grip Strength of Arm Wrestlers
ERIC Educational Resources Information Center
Yonca, Sezer S.; Engin, Çelikel B.; Serdar, Yücel A.; Mustafa, Karadag; Yüksel, Savucu
2017-01-01
The aim of this research is to evaluate the change in the hand grip strength of the male arm wrestlers before and after a unit of exercise. The participants of the research consist of sportsmen (n=16) of Firat University arm wrestling team in 18-25 age group. Within the scope of the research, all of the tests and measurements (age, length, body…
Theory and simulation of multi-channel interference (MCI) widely tunable lasers.
Chen, Quanan; Lu, Qiaoyin; Guo, Weihua
2015-07-13
A novel design of an InP-based monolithic widely tunable laser, multi-channel interference (MCI) laser, is proposed and presented for the first time. The device is comprised of a gain section, a common phase section and a multi-channel interference section. The multi-channel interference section contains a 1x8 splitter based on cascaded 1 × 2 multi-mode interferometers (MMIs) and eight arms with unequal length difference. The rear part of each arm is integrated with a one-port multi-mode interference reflector (MIR). Mode selection of the MCI laser is realized by the constructive interference of the lights reflected back by the eight arms. Through optimizing the arm length difference, a tuning range of more than 40 nm covering the whole C band, a threshold current around 11.5 mA and an side-mode-suppression-ratio (SMSR) up to 48 dB have been predicted for this widely tunable laser. Detailed design principle and numerical simulation results are presented.
An Interlaminar Tensile Strength Specimen
NASA Technical Reports Server (NTRS)
Martin, Roderick H.; Jackson, Wade C.
1993-01-01
This paper describes a technique to determine interlaminar tensile strength, sigma(sub 3c), of a fiber reinforced composite material using a curved beam. The specimen was a unidirectional curved beam, bent 90 deg, with straight arms. Attached to each arm was a hinged loading mechanism that was held by the grips of a tension testing machine. Geometry effects of the specimen, including the effects of loading arm length, inner radius, thickness, and width, were studied. The data sets fell into two categories: low strength corresponding to a macroscopic flaw related failure and high strength corresponding to a microscopic flaw related failure. From the data available, the specimen width and loading arm length had little effect on sigma(sub 3c). The inner radius was not expected to have a significant effect on sigma(sub 3c), but this conclusion could not be confirmed because of differences in laminate quality for each curve geometry. The thicker specimens had the lowest value of sigma(sub 3c) because of poor laminate quality.
Shah, P; Jhaveri, U; Idhate, T B; Dhingra, S; Arolkar, P; Arora, B
2015-01-01
In India, approximately 40,000 new cases of cancer in children are diagnosed each year. However, there are no good studies analyzing their nutritional status. Also, since accurate and sensitive nutritional assessment is critical for optimal clinical outcomes through timely remediation of malnutrition, it is important to assess the relative sensitivity and feasibility of commonly used nutritional screening tools. This observational study analyzed height/length (cm), weight (kg), mid-upper arm circumference (MUAC), triceps skinfold thickness (TSFT) as well as their Z-scores or percentiles, albumin levels and history of weight loss at diagnosis in children aged 2-15 years being treated for cancer between November 2008 to December 2013. Body mass index (BMI) and arm muscle circumference (AMC) were calculated respectively from height and weight, and MUAC and TSFT. A total of 1693 new patients were enrolled; 1187 had all anthropometric measurements performed. The prevalence of malnutrition was 38%, 57%, 76%, 69% and 81% on the basis of BMI, TSFT, MUAC, AMC, and arm TSFT + MUAC respectively with the highest prevalence in solid abdominal tumours. Addition of BMI and serum albumin to arm anthropometry increased the proportion classified as severely nutritionally depleted by a mere 2% & 1.5% respectively. Positive history of significant weight loss additionally identified 16.5% at nutritional risk over arm anthropometry. The prevalence of malnutrition in Indian children with cancer at presentation is very high ranging from 40% and 80% depending on the method used for assessment, being higher with MUAC and lowest with BMI. Either MUAC alone or TSFT + MUAC (wherever feasible) should be used for screening for malnutrition in children with cancer at diagnosis to plan timely nutritional interventions, reduce the treatment-related morbidity and optimise their chance of long-term cure.
A new index of flat breaststroke propulsion: a comparison of elite men and women.
Seifert, L; Chollet, D
2005-03-01
This study examined arm and leg coordination and propulsion during the flat breaststroke in nine elite male and eight elite female swimmers over three race paces (200 m, 100 m and 50 m). Coordination was expressed using four temporal gaps (T1, T2, T3, T4), which described the continuity between the propulsive phases of the limbs, as recorded on a video device (50 Hz). Glide duration was denoted T1, the time between the beginning of arm and leg recovery was denoted T2, the time between the end of arm and the leg recovery was denoted T3, and the time between 90 degrees of flexion during arm recovery and 90 degrees during leg recovery was denoted T4. Using these temporal gaps, four stroke phases (propulsion, glide, recovery and leg insweep) could be followed over a complete arm and leg stroke. The total duration of arm and leg propulsion was assessed by a new index of flat breaststroke propulsion (IFBP). Velocity, stroke rate and stroke length were also calculated for each pace. The elite swimmers showed short T2, T3 and T4; moreover, T1 decreased when the pace increased. Expertise in the flat breaststroke was thus characterized by synchronized arm and leg recoveries and increased continuity in the arm and leg propulsions with increasing velocity. Differences between the sexes in the spatio-temporal parameters were possibly due to anthropometric differences (the men were heavier, older and taller than the women) and different motor organization linked to arm and leg coordination (shorter T3, body glide and body recovery, and greater body propulsion and higher IFBP in the men). The men's propulsive actions showed greater continuity, particularly in the sprint. The best men adopted a superposition coordination and thus had the ability to overcome very great active drag. Temporal gap measurement and the IFBP are practical indicators of arm and leg coordination and propulsion that can be exploited by coaches and swimmers to increase the continuity between propulsive actions during the flat breaststroke.
Innovative virtual reality measurements for embryonic growth and development.
Verwoerd-Dikkeboom, C M; Koning, A H J; Hop, W C; van der Spek, P J; Exalto, N; Steegers, E A P
2010-06-01
Innovative imaging techniques, using up-to-date ultrasonic equipment, necessitate specific biometry. The aim of our study was to test the possibility of detailed human embryonic biometry using a virtual reality (VR) technique. In a longitudinal study, three-dimensional (3D) measurements were performed from 6 to 14 weeks gestational age in 32 pregnancies (n = 16 spontaneous conception, n = 16 IVF/ICSI). A total of 125 3D volumes were analysed in the I-Space VR system, which allows binocular depth perception, providing a realistic 3D illusion. Crown-rump length (CRL), biparietal diameter (BPD), occipito-frontal diameter (OFD), head circumference (HC) and abdominal circumference (AC) were measured as well as arm length, shoulder width, elbow width, hip width and knee width. CRL, BPD, OFD and HC could be measured in more than 96% of patients, and AC in 78%. Shoulder width, elbow width, hip width and knee width could be measured in more than 95% of cases, and arm length in 82% of cases. Growth curves were constructed for all variables. Ear and foot measurements were only possible beyond 9 weeks gestation. This study provides a detailed, longitudinal description of normal human embryonic growth, facilitated by a VR system. Growth curves were created for embryonic biometry of the CRL, BPD, HC and AC early in pregnancy and also of several 'new' biometric measurements. Applying virtual embryoscopy will enable us to diagnose growth and/or developmental delay earlier and more accurately. This is especially important for pregnancies at risk of severe complications, such as recurrent late miscarriage and early growth restriction.
Sisunandar; Rival, Alain; Turquay, Patricia; Samosir, Yohannes; Adkins, Steve W
2010-07-01
The present study aimed at exploring the fidelity of coconut (Cocos nucifera L.) plants recovered from cryopreservation. Zygotic embryos from various different cultivars were cryopreserved following four successive steps, namely: rapid dehydration, rapid freezing, rapid thawing and in vitro recovery followed by acclimatization. At the end of the acclimatization period, the seedlings were compared to counterparts of the same age, which were produced from non-cryopreserved embryos. Both series were submitted to morphological, cytological and molecular comparisons. No significant differences in terms of growth rates could be measured. In addition, no morphological variation could be detected through the measurement of shoot elongation rates, production of opened leaves, and the number and total length of primary roots. Karyotype analysis revealed the same chromosome number (2n = 32) in all studied cultivars independently of cryopreservation. No significant differences could be observed between control and cryopreserved material concerning the type of chromosomes, the length of the long and short arms, the arm length ratio and the centromeric index. However, idiogram analysis did show a greater number of black banding on chromosomes isolated from cryopreserved material. Genetic and epigenetic fidelity was assessed through microsatellite (SSR) analysis and global DNA methylation rates; no significant differences would be observed between genomic DNAs isolated from seedlings originating from cryopreserved embryos and respective controls. In conclusion, our results suggest that the method of cryopreservation under study did not induce gross morphological, genetic or epigenetic changes, thus suggesting that it is an appropriate method to efficiently preserve coconut germplasm.
Kröger, Niklas; Schlobohm, Jochen; Pösch, Andreas; Reithmeier, Eduard
2017-09-01
In Michelson interferometer setups the standard way to generate different optical path lengths between a measurement arm and a reference arm relies on expensive high precision linear stages such as piezo actuators. We present an alternative approach based on the refraction of light at optical interfaces using a cheap stepper motor with high gearing ratio to control the rotation of a glass plate. The beam path is examined and a relation between angle of rotation and change in optical path length is devised. As verification, an experimental setup is presented, and reconstruction results from a measurement standard are shown. The reconstructed step height from this setup lies within 1.25% of the expected value.
30 CFR 1206.461 - Determination of transportation allowances.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 3 2012-07-01 2012-07-01 false Determination of transportation allowances... INTERIOR NATURAL RESOURCES REVENUE PRODUCT VALUATION Indian Coal § 1206.461 Determination of transportation allowances. (a) Arm's-length contracts. (1) For transportation costs incurred by a lessee pursuant to an arm...
30 CFR 1206.461 - Determination of transportation allowances.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 3 2014-07-01 2014-07-01 false Determination of transportation allowances... INTERIOR NATURAL RESOURCES REVENUE PRODUCT VALUATION Indian Coal § 1206.461 Determination of transportation allowances. (a) Arm's-length contracts. (1) For transportation costs incurred by a lessee pursuant to an arm...
30 CFR 1206.461 - Determination of transportation allowances.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 3 2013-07-01 2013-07-01 false Determination of transportation allowances... INTERIOR NATURAL RESOURCES REVENUE PRODUCT VALUATION Indian Coal § 1206.461 Determination of transportation allowances. (a) Arm's-length contracts. (1) For transportation costs incurred by a lessee pursuant to an arm...
Peek, G J; Elbourne, D; Mugford, M; Tiruvoipati, R; Wilson, A; Allen, E; Clemens, F; Firmin, R; Hardy, P; Hibbert, C; Jones, N; Killer, H; Thalanany, M; Truesdale, A
2010-07-01
To determine the comparative effectiveness and cost-effectiveness of conventional ventilatory support versus extracorporeal membrane oxygenation (ECMO) for severe adult respiratory failure. A multicentre, randomised controlled trial with two arms. The ECMO centre at Glenfield Hospital, Leicester, and approved conventional treatment centres and referring hospitals throughout the UK. Patients aged 18-65 years with severe, but potentially reversible, respiratory failure, defined as a Murray lung injury score > or = 3.0, or uncompensated hypercapnoea with a pH < 7.20 despite optimal conventional treatment. Participants were randomised to conventional management (CM) or to consideration of ECMO. The primary outcome measure was death or severe disability at 6 months. Secondary outcomes included a range of hospital indices: duration of ventilation, use of high frequency/oscillation/jet ventilation, use of nitric oxide, prone positioning, use of steroids, length of intensive care unit stay, and length of hospital stay - and (for ECMO patients only) mode (venovenous/veno-arterial), duration of ECMO, blood flow and sweep flow. A total of 180 patients (90 in each arm) were randomised from 68 centres. Three patients in the conventional arm did not give permission to be followed up. Of the 90 patients randomised to the ECMO arm, 68 received that treatment. ECMO was not given to three patients who died prior to transfer, two who died in transit, 16 who improved with conventional treatment given by the ECMO team and one who required amputation and could not therefore be heparinised. Ninety patients entered the CM (control) arm, three patients later withdrew and refused follow-up (meaning that they were alive), leaving 87 patients for whom primary outcome measures were available. CM consisted of any treatment deemed appropriate by the patient's intensivist with the exception of extracorporeal gas exchange. No CM patients received ECMO, although one received a form of experimental extracorporeal arteriovenous carbon dioxide removal support (a clear protocol violation). Fewer patients in the ECMO arm than in the CM arm had died or were severely disabled 6 months after randomisation, [33/90 (36.7%) versus 46/87 (52.9%) respectively]. This equated to one extra survivor for every six patients treated. Only one patient (in the CM arm) was known to be severely disabled at 6 months. Patients allocated to ECMO incurred average total costs of 73,979 pounds compared with 33,435 pounds for those undergoing CM (UK prices, 2005). A lifetime model predicted the cost per quality-adjusted life-year (QALY) of ECMO to be 19,252 pounds (95% confidence interval 7622 pounds to 59,200 pounds) at a discount rate of 3.5%. Lifetime QALYs gained were 10.75 for the ECMO group compared with 7.31 for the conventional group. Costs to patients and their relatives, including out of pocket and time costs, were higher for patients allocated to ECMO. Compared with CM, transferring adult patients with severe but potentially reversible respiratory failure to a single centre specialising in the treatment of severe respiratory failure for consideration of ECMO significantly increased survival without severe disability. Use of ECMO in this way is likely to be cost-effective when compared with other technologies currently competing for health resources. Current Controlled Trials ISRCTN47279827.
Fitz-Gerald, Alison Louise; Tan, Jason; Chan, Kok-Weng; Polyakov, Alex; Edwards, Geoff N; Najjar, Haider; Tsaltas, Jim; Vollenhoven, Beverley
2013-01-01
To compare operating time, intraoperative blood loss, postoperative analgesia, and length of hospital stay using ultrasonic shears vs traditional suture ligature in vaginal hysterectomy. Randomized controlled trial (Canadian Task Force classification I). Gynecology units within a single health network, university hospital. Forty women requiring vaginal hysterectomy because of benign disease. Vaginal hysterectomy performed using either ultrasonically activated shears (USS) or traditional suture ligatures. Twenty-one patients were randomized to the USS arm, and 19 patients to the traditional suture ligature arm. Patient characteristics were comparable. Mean (SD) hysterectomy time and was similar in both the USS and traditional arms, 28.66 (4.0) minutes vs 32.37 (3.18) minutes (p = .47), as was total operating time, 97.38 (8.9) minutes vs 91.63 (7.69) minutes (p = .63). Operative blood loss was significantly decreased in the USS group: 62.63 (12.46) mL vs 136.05 (21.54) mL (p = .006). There was, however, no significant change in hemoglobin concentration between the 2 groups: 19.53 (1.79) g/L vs -16.72 (2.5) g/L. There was no significant difference in mean oxycodone use: 9.29 (2.66) mg vs 8.06 (3.19) mg (p = .77). Length of hospital stay was similar in both groups: 58.98 (3.27) hours vs 60.05 (6.48) hours (p = .88). There was no significant difference in overall complication rates between the groups. Although the Harmonic scalpel system, compared with the traditional suture ligation method, seems to be a safe alternative for securing the pedicles in vaginal hysterectomy, it offers no benefit insofar as operative time, reduction in clinically significant blood loss, and analgesic requirements. Copyright © 2013 AAGL. Published by Elsevier Inc. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-08
... production method. 1206.259(c)(1)(ii) and (c)(2)(iii). Submit arm's-length and non- AUDIT PROCESS (See Note...-length AUDIT PROCESS (See Note). transportation contracts, production agreements, operating agreements...-length AUDIT PROCESS (See Note). power plant contracts, production and operating agreements and related...
NASA Astrophysics Data System (ADS)
Adhikari, K.; Choudhury, S.; Mandal, R.; Barman, S.; Otani, Y.; Barman, A.
2017-01-01
Ferromagnetic nano-cross structures promise exotic static magnetic configurations and very rich and tunable magnetization dynamics leading towards potential applications in magnetic logic and communication devices. Here, we report an experimental study of external magnetic field tunable static magnetic configurations and magnetization dynamics in Ni80Fe20 nano-cross structures with varying arm lengths (L). Broadband ferromagnetic resonance measurements showed a strong variation in the number of spin-wave (SW) modes and mode frequencies (f) with bias field magnitude (H). Simulated static magnetic configurations and SW mode profiles explain the rich variation of the SW spectra, including mode softening, mode crossover, mode splitting, and mode merging. Such variation of SW spectra is further modified by the size of the nano-cross. Remarkably, with decreasing arm length of nano-cross structures, the onion magnetization ground state becomes more stable. Calculated magnetostatic field distributions support the above observations and revealed the non-collective nature of the dynamics in closely packed nano-cross structures. The latter is useful for their possible applications in magnetic storage and memory devices.
Thermoelectric Mixed Thick-/Thin Film Microgenerators Based on Constantan/Silver.
Gierczak, Mirosław; Prażmowska-Czajka, Joanna; Dziedzic, Andrzej
2018-01-12
This paper describes the design, manufacturing and characterization of newly developed mixed thick-/thin film thermoelectric microgenerators based on magnetron sputtered constantan (copper-nickel alloy) and screen-printed silver layers. The thermoelectric microgenerator consists of sixteen thermocouples made on a 34.2 × 27.5 × 0.25 mm³ alumina substrate. One of thermocouple arms was made of magnetron-sputtered constantan (Cu-Ni alloy), the second was a Ag-based screen-printed film. The length of each thermocouple arm was equal to 27 mm, and their width 0.3 mm. The distance between the arms was equal to 0.3 mm. In the first step, a pattern mask with thermocouples was designed and fabricated. Then, a constantan layer was magnetron sputtered over the whole substrate, and a photolithography process was used to prepare the first thermocouple arms. The second arms were screen-printed onto the substrate using a low-temperature silver paste (Heraeus C8829A or ElectroScience Laboratories ESL 599-E). To avoid oxidation of constantan, they were fired in a belt furnace in a nitrogen atmosphere at 550/450 °C peak firing temperature. Thermoelectric and electrical measurements were performed using the self-made measuring system. Two pyrometers included into the system were used for temperature measurement of hot and cold junctions. The estimated Seebeck coefficient, α was from the range 35 - 41 µV/K, whereas the total internal resistances R were between 250 and 3200 ohms, depending on magnetron sputtering time and kind of silver ink (the resistance of a single thermocouple was between 15.5 and 200 ohms).
Thermoelectric Mixed Thick-/Thin Film Microgenerators Based on Constantan/Silver
Gierczak, Mirosław; Prażmowska-Czajka, Joanna; Dziedzic, Andrzej
2018-01-01
This paper describes the design, manufacturing and characterization of newly developed mixed thick-/thin film thermoelectric microgenerators based on magnetron sputtered constantan (copper-nickel alloy) and screen-printed silver layers. The thermoelectric microgenerator consists of sixteen thermocouples made on a 34.2 × 27.5 × 0.25 mm3 alumina substrate. One of thermocouple arms was made of magnetron-sputtered constantan (Cu-Ni alloy), the second was a Ag-based screen-printed film. The length of each thermocouple arm was equal to 27 mm, and their width 0.3 mm. The distance between the arms was equal to 0.3 mm. In the first step, a pattern mask with thermocouples was designed and fabricated. Then, a constantan layer was magnetron sputtered over the whole substrate, and a photolithography process was used to prepare the first thermocouple arms. The second arms were screen-printed onto the substrate using a low-temperature silver paste (Heraeus C8829A or ElectroScience Laboratories ESL 599-E). To avoid oxidation of constantan, they were fired in a belt furnace in a nitrogen atmosphere at 550/450 °C peak firing temperature. Thermoelectric and electrical measurements were performed using the self-made measuring system. Two pyrometers included into the system were used for temperature measurement of hot and cold junctions. The estimated Seebeck coefficient, α was from the range 35 − 41 µV/K, whereas the total internal resistances R were between 250 and 3200 ohms, depending on magnetron sputtering time and kind of silver ink (the resistance of a single thermocouple was between 15.5 and 200 ohms). PMID:29329203
Pomeroy, Emma; Stock, Jay T; Cole, Tim J; O'Callaghan, Michael; Wells, Jonathan C K
2014-01-01
Low birth weight has been consistently associated with adult chronic disease risk. The thrifty phenotype hypothesis assumes that reduced fetal growth impacts some organs more than others. However, it remains unclear how birth weight relates to different body components, such as circumferences, adiposity, body segment lengths and limb proportions. We hypothesized that these components vary in their relationship to birth weight. We analysed the relationship between birth weight and detailed anthropometry in 1270 singleton live-born neonates (668 male) from the Mater-University of Queensland Study of Pregnancy (Brisbane, Australia). We tested adjusted anthropometry for correlations with birth weight. We then performed stepwise multiple regression on birth weight of: body lengths, breadths and circumferences; relative limb to neck-rump proportions; or skinfold thicknesses. All analyses were adjusted for sex and gestational age, and used logged data. Circumferences, especially chest, were most strongly related to birth weight, while segment lengths (neck-rump, thigh, upper arm, and especially lower arm and lower leg) were relatively weakly related to birth weight, and limb lengths relative to neck-rump length showed no relationship. Skinfolds accounted for 36% of birth weight variance, but adjusting for size (neck-rump, thigh and upper arm lengths, and head circumference), this decreased to 10%. There was no evidence that heavier babies had proportionally thicker skinfolds. Neonatal body measurements vary in their association with birth weight: head and chest circumferences showed the strongest associations while limb segment lengths did not relate strongly to birth weight. After adjusting for body size, subcutaneous fatness accounted for a smaller proportion of birth weight variance than previously reported. While heavier babies had absolutely thicker skinfolds, this was proportional to their size. Relative limb to trunk length was unrelated to birth weight, suggesting that limb proportions at birth do not index factors relevant to prenatal life.
Pomeroy, Emma; Stock, Jay T.; Cole, Tim J.; O'Callaghan, Michael; Wells, Jonathan C. K.
2014-01-01
Background Low birth weight has been consistently associated with adult chronic disease risk. The thrifty phenotype hypothesis assumes that reduced fetal growth impacts some organs more than others. However, it remains unclear how birth weight relates to different body components, such as circumferences, adiposity, body segment lengths and limb proportions. We hypothesized that these components vary in their relationship to birth weight. Methods We analysed the relationship between birth weight and detailed anthropometry in 1270 singleton live-born neonates (668 male) from the Mater-University of Queensland Study of Pregnancy (Brisbane, Australia). We tested adjusted anthropometry for correlations with birth weight. We then performed stepwise multiple regression on birth weight of: body lengths, breadths and circumferences; relative limb to neck-rump proportions; or skinfold thicknesses. All analyses were adjusted for sex and gestational age, and used logged data. Results Circumferences, especially chest, were most strongly related to birth weight, while segment lengths (neck-rump, thigh, upper arm, and especially lower arm and lower leg) were relatively weakly related to birth weight, and limb lengths relative to neck-rump length showed no relationship. Skinfolds accounted for 36% of birth weight variance, but adjusting for size (neck-rump, thigh and upper arm lengths, and head circumference), this decreased to 10%. There was no evidence that heavier babies had proportionally thicker skinfolds. Conclusions Neonatal body measurements vary in their association with birth weight: head and chest circumferences showed the strongest associations while limb segment lengths did not relate strongly to birth weight. After adjusting for body size, subcutaneous fatness accounted for a smaller proportion of birth weight variance than previously reported. While heavier babies had absolutely thicker skinfolds, this was proportional to their size. Relative limb to trunk length was unrelated to birth weight, suggesting that limb proportions at birth do not index factors relevant to prenatal life. PMID:25162658
Plys, Aaron J.; Rogacheva, Maria V.; Greene, Eric C.; Alani, Eric
2012-01-01
DNA mismatch repair (MMR) models have proposed that MSH proteins identify DNA polymerase errors while interacting with the DNA replication fork. MLH proteins (primarily Mlh1-Pms1 in baker’s yeast) then survey the genome for lesion-bound MSH proteins. The resulting MSH-MLH complex formed at a DNA lesion initiates downstream steps in repair. MLH proteins act as dimers and contain long (20 – 30 nanometers) unstructured arms that connect two terminal globular domains. These arms can vary between 100 to 300 amino acids in length, are highly divergent between organisms, and are resistant to amino acid substitutions. To test the roles of the linker arms in MMR, we engineered a protease cleavage site into the Mlh1 linker arm domain of baker’s yeast Mlh1-Pms1. Cleavage of the Mlh1 linker arm in vitro resulted in a defect in Mlh1-Pms1 DNA binding activity, and in vivo proteolytic cleavage resulted in a complete defect in MMR. We then generated a series of truncation mutants bearing Mlh1 and Pms1 linker arms of varying lengths. This work revealed that MMR is greatly compromised when portions of the Mlh1 linker are removed, whereas repair is less sensitive to truncation of the Pms1 linker arm. Purified complexes containing truncations in Mlh1 and Pms1 linker arms were analyzed and found to have differential defects in DNA binding that also correlated with the ability to form a ternary complex with Msh2-Msh6 and mismatch DNA. These observations are consistent with the unstructured linker domains of MLH proteins providing distinct interactions with DNA during MMR. PMID:22659005
Preconception maternal nutrition: a multi-site randomized controlled trial
2014-01-01
Background Research directed to optimizing maternal nutrition commencing prior to conception remains very limited, despite suggestive evidence of its importance in addition to ensuring an optimal nutrition environment in the periconceptional period and throughout the first trimester of pregnancy. Methods/Study design This is an individually randomized controlled trial of the impact on birth length (primary outcome) of the time at which a maternal nutrition intervention is commenced: Arm 1: ≥ 3 mo preconception vs. Arm 2: 12-14 wk gestation vs. Arm 3: none. 192 (derived from 480) randomized mothers and living offspring in each arm in each of four research sites (Guatemala, India, Pakistan, Democratic Republic of the Congo). The intervention is a daily 20 g lipid-based (118 kcal) multi-micronutient (MMN) supplement. Women randomized to receive this intervention with body mass index (BMI) <20 or whose gestational weight gain is low will receive an additional 300 kcal/d as a balanced energy-protein supplement. Researchers will visit homes biweekly to deliver intervention and monitor compliance, pregnancy status and morbidity; ensure prenatal and delivery care; and promote breast feeding. The primary outcome is birth length. Secondary outcomes include: fetal length at 12 and 34 wk; incidence of low birth weight (LBW); neonatal/infant anthropometry 0-6 mo of age; infectious disease morbidity; maternal, fetal, newborn, and infant epigenetics; maternal and infant nutritional status; maternal and infant microbiome; gut inflammatory biomarkers and bioactive and nutritive compounds in breast milk. The primary analysis will compare birth Length-for-Age Z-score (LAZ) among trial arms (independently for each site, estimated effect size: 0.35). Additional statistical analyses will examine the secondary outcomes and a pooled analysis of data from all sites. Discussion Positive results of this trial will support a paradigm shift in attention to nutrition of all females of child-bearing age. Trial registration ClinicalTrials.gov NCT01883193. PMID:24650219
Stulberg, Jonah J; Pavey, Emily S; Cohen, Mark E; Ko, Clifford Y; Hoyt, David B; Bilimoria, Karl Y
2017-02-01
Changes to resident duty hour policies in the Flexibility in Duty Hour Requirements for Surgical Trainees (FIRST) trial could impact hospitalized patients' length of stay (LOS) by altering care coordination. Length of stay can also serve as a reflection of all complications, particularly those not captured in the FIRST trial (eg pneumothorax from central line). Programs were randomized to either maintaining current ACGME duty hour policies (Standard arm) or more flexible policies waiving rules on maximum shift lengths and time off between shifts (Flexible arm). Our objective was to determine whether flexibility in resident duty hours affected LOS in patients undergoing high-risk surgical operations. Patients were identified who underwent hepatectomy, pancreatectomy, laparoscopic colectomy, open colectomy, or ventral hernia repair (2014-2015 academic year) at 154 hospitals participating in the FIRST trial. Two procedure-stratified evaluations of LOS were undertaken: multivariable negative binomial regression analysis on LOS and a multivariable logistic regression analysis on the likelihood of a prolonged LOS (>75 th percentile). Before any adjustments, there was no statistically significant difference in overall mean LOS between study arms (Flexible Policy: mean [SD] LOS 6.03 [5.78] days vs Standard Policy: mean LOS 6.21 [5.82] days; p = 0.74). In adjusted analyses, there was no statistically significant difference in LOS between study arms overall (incidence rate ratio for Flexible vs Standard: 0.982; 95% CI, 0.939-1.026; p = 0.41) or for any individual procedures. In addition, there was no statistically significant difference in the proportion of patients with prolonged LOS between study arms overall (Flexible vs Standard: odds ratio = 1.028; 95% CI, 0.871-1.212) or for any individual procedures. Duty hour flexibility had no statistically significant effect on LOS in patients undergoing complex intra-abdominal operations. Copyright © 2016 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Lei, Yuming; Wang, Jinsung
2014-11-01
Learning a visumotor adaptation task with one arm typically facilitates subsequent performance with the other. The extent of transfer across the arms, however, is generally much smaller than that across different conditions within the same arm. This may be attributed to a possibility that intralimb transfer involves both algorithmic and instance-reliant learning, whereas interlimb transfer only involves algorithmic learning. Here, we investigated whether prolonged training with one arm could facilitate subsequent performance with the other arm to a greater extent, by examining the effect of varying lengths of practice trials on the extent of interlimb transfer. We had 18 subjects adapt to a 30° visuomotor rotation with the left arm first (training), then with the right arm (transfer). During the training session, the subjects reached toward multiple targets for 160, 320 or 400 trials; during the transfer session, all subjects performed the same task for 160 trials. Our results revealed substantial initial transfer from the left to the right arm in all three conditions. However, neither the amount of initial transfer nor the rate of adaptation during the transfer session was significantly different across the conditions, indicating that the extent of transfer was similar regardless of the length of initial training. Our findings suggest that interlimb transfer of visuomotor adaptation may only occur through algorithmic learning, which is effector independent, and that prolonged training may only have beneficial effects when instance-reliant learning, which is effector dependent, is also involved in the learning process. Copyright © 2014 Elsevier Inc. All rights reserved.
Hillier, Susan; English, Coralie; Crotty, Maria; Segal, Leonie; Bernhardt, Julie; Esterman, Adrian
2011-12-01
There is strong evidence for a dose-response relationship between physical therapy early after stroke and recovery of function. The optimal method of maximizing physical therapy within finite health care resources is unknown. To determine the effectiveness and cost-effectiveness of two alternative models of physical therapy service delivery (seven-days per week therapy services or group circuit class therapy over five-days a week) to usual care for people receiving inpatient rehabilitation after stroke. Multicenter, three-armed randomized controlled trial with blinded assessment of outcomes. A total of 282 people admitted to inpatient rehabilitation facilities after stroke with an admission functional independence measure (FIM) score within the moderate range (total 40-80 points or motor 38-62 points) will be randomized to receive one of three interventions: • usual care therapy over five-days a week • standard care therapy over seven-days a week, or • group circuit class therapy over five-days a week. Participants will receive the allocated intervention for the length of their hospital stay. Analysis will be by intention-to-treat. The primary outcome measure is walking ability (six-minute walk test) at four-week postintervention with three- and six-month follow-up. Economic analysis will include a costing analysis based on length of hospital stay and staffing/resource costs and a cost-utility analysis (incremental quality of life per incremental cost, relative to usual care). Secondary outcomes include walking speed and independence, ability to perform activities of daily living, arm function, quality of life and participant satisfaction. © 2011 The Authors. International Journal of Stroke © 2011 World Stroke Organization.
Myint, Ma Wai Wai; Wu, Jenny; Wong, Euann; Chan, Suk Ping; To, Tze Shing Jess; Chau, Mei Wa Rosanna; Ting, Kwai Hing; Fung, Pui Man; Au, Kit Sing Derrick
2013-01-01
malnutrition is an important risk factor for poor outcome in patients recovering after hip fracture surgery. This study aimed to investigate the clinical, nutritional and rehabilitation effects of an oral nutritional supplementation (ONS) in an inpatient rehabilitation setting. this was an observer-blinded randomised controlled trial of elderly post-surgical proximal femoral fracture patients. A ready-to-use oral liquid nutritional supplementation (18-24 g protein and 500 kcal per day) in addition to hospital diet was compared with hospital diet only. Both groups received usual rehabilitation therapy and oral calcium and vitamin D supplements. Outcomes were compared at discharge from rehabilitation and after 4 weeks of discharge. The primary outcome parameters were the serum albumin level, the body mass index (BMI), the functional independence measure (FIM) and the elderly mobility scale (EMS). Secondary outcome parameters were frequency of complications, inpatient length of stay, mortality and acute hospital use within 6 months after discharge. a total of 126 patients were recruited, 65 in the supplementation arm and 61 in the control arm. There was a significant difference in change in BMI with a decrease of 0.25 and 0.03 kg/m(2) in the ONS group and 0.72 and 0.49 kg/m(2) in the control group at hospital discharge and follow-up, respectively (P = 0.012). The length of stay in rehabilitation ward was shortened by 3.80 (SE = 1.81, P = 0.04) days favouring the ONS group. The total number of infection episodes was also reduced significantly. No difference was observed in the rate of change of the serum albumin level, the FIM and the EMS. clinical and nutritional benefits were seen in this trial but rehabilitation benefits could not be demonstrated.
High-resolution crossover maps for each bivalent of Zea mays using recombination nodules.
Anderson, Lorinda K; Doyle, Gregory G; Brigham, Brian; Carter, Jenna; Hooker, Kristina D; Lai, Ann; Rice, Mindy; Stack, Stephen M
2003-01-01
Recombination nodules (RNs) are closely correlated with crossing over, and, because they are observed by electron microscopy of synaptonemal complexes (SCs) in extended pachytene chromosomes, RNs provide the highest-resolution cytological marker currently available for defining the frequency and distribution of crossovers along the length of chromosomes. Using the maize inbred line KYS, we prepared an SC karyotype in which each SC was identified by relative length and arm ratio and related to the proper linkage group using inversion heterozygotes. We mapped 4267 RNs on 2080 identified SCs to produce high-resolution maps of RN frequency and distribution on each bivalent. RN frequencies are closely correlated with both chiasma frequencies and SC length. The total length of the RN recombination map is about twofold shorter than that of most maize linkage maps, but there is good correspondence between the relative lengths of the different maps when individual bivalents are considered. Each bivalent has a unique distribution of crossing over, but all bivalents share a high frequency of distal RNs and a severe reduction of RNs at and near kinetochores. The frequency of RNs at knobs is either similar to or higher than the average frequency of RNs along the SCs. These RN maps represent an independent measure of crossing over along maize bivalents. PMID:14573493
Coordination and propulsion and non-propulsion phases in 100 meter breaststroke swimming.
Strzała, Marek; Krężałek, Piotr; Kucia-Czyszczoń, Katarzyna; Ostrowski, Andrzej; Stanula, Arkadiusz; Tyka, Anna K; Sagalara, Andrzej
2014-01-01
The main purpose of this study was to analyze the coordination, propulsion and non-propulsion phases in the 100 meter breaststroke race. Twenty-seven male swimmers (15.7 ± 1.98 years old) with the total body length (TBL) of 247.0 ± 10.60 [cm] performed an all-out 100 m breaststroke bout. The bouts were recorded with an underwater camera installed on a portable trolley. The swimming kinematic parameters, stroke rate (SR) and stroke length (SL), as well as the coordination indices based on propulsive or non-propulsive movement phases of the arms and legs were distinguished. Swimming speed (V100surface breast) was associated with SL (R = 0.41, p < 0.05) and with TBL tending towards statistical significance (R = 0.36, p < 0.07), all relationships between the selected variables in the study were measured using partial correlations with controlled age. SL interplayed negatively with the limbs propulsive phase Overlap indicator (R = -0.46, p < 0.05), but had no significant relationship to the non-propulsion Glide indicator. The propulsion in-sweep (AP3) phase of arms and their non-propulsion partial air recovery (ARair) phase interplayed with V100surface breast (R = 0.51, p < 0.05 and 0.48 p < 0.05) respectively, displaying the importance of proper execution of this phase (AP3) and in reducing the resistance recovery phases in consecutive ones.
Su, Yuxi; Nan, Guoxin
2016-05-01
Embedment of metallic foreign bodies in the soft tissues is commonly encountered in the emergency room. Most foreign bodies are easily removed, but removal is difficult if the foreign body is very small or deeply embedded. To determine the usefulness of methylene blue staining in the surgical removal of tiny metallic foreign bodies embedded in the soft tissue. This prospective study involved 41 children treated between May 2007 and May 2012. The patients were randomly divided into a methylene blue group and a control group. In the control group, foreign bodies were located using a C-arm and removed via direct incision. In the methylene blue group, foreign bodies were located using a C-arm, marked with an injection of methylene blue and then removed surgically. The clinical outcomes, complications, operation time, surgical success rate, incision length, frequency of C-arm use, and length and depth of the foreign body were compared between the two groups. The surgical success rate was significantly higher in the methylene blue group. The average operation time was significantly shorter in the methylene blue group. The C-arm was used significantly less frequently in the methylene blue group than in the control group. The incision length was significantly shorter in the methylene blue group than in the control group. Methylene blue staining facilitated the location and removal of tiny metallic foreign bodies from the soft tissue, and significantly reduced operation time, incision length and radiation exposure compared to the conventional method. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
Agresta, Cristine; Ward, Christian R; Wright, W Geoffrey; Tucker, Carole A
2018-06-01
Many field sports involve equipment that restricts one or both arms from moving while running. Arm swing during running has been examined from a biomechanical and physiologic perspective but not from an injury perspective. Moreover, only bilateral arm swing suppression has been studied with respect to running. The purpose of this study was to determine the influence of running with one arm restrained on lower extremity mechanics associated with running or sport-related injury. Fifteen healthy participants ran at a self-selected speed with typical arm swing, with one arm restrained and with both arms restrained. Lower extremity kinematics and spatiotemporal measures were analysed for all arm swing conditions. Running with one arm restrained resulted in increased frontal plane knee and hip angles, decreased foot strike angle, and decreased centre of mass vertical displacement compared to typical arm swing or bilateral arm swing restriction. Stride length was decreased and step frequency increased when running with one or both arms restrained. Unilateral arm swing restriction induces changes in lower extremity kinematics that are not similar to running with bilateral arm swing restriction or typical arm swing motion. Running with one arm restrained increases frontal plane mechanics associated with risk of knee injury.
Possible Periodic Orbit Control Maneuvers for an eLISA Mission
NASA Technical Reports Server (NTRS)
Bender, Peter L.; Welter, Gary L.
2012-01-01
This paper investigates the possible application of periodic orbit control maneuvers for so-called evolved-LISA (eLISA) missions, i.e., missions for which the constellation arm lengths and mean distance from the Earth are substantially reduced. We find that for missions with arm lengths of 106 km and Earth-trailing distance ranging from approx. 12deg to 20deg over the science lifetime, the occasional use of the spacecraft micro-Newton thrusters for constellation configuration maintenance should be able to essentially eliminate constellation distortion caused by Earth-induced tidal forces at a cost to science time of only a few percent. With interior angle variation kept to approx. +/-0:1deg, the required changes in the angles between the laser beam pointing directions for the two arms from any spacecraft could be kept quite small. This would considerably simplify the apparatus necessary for changing the transmitted beam directions.
Siu King Cheung, Catherine; Tak Keung Lee, Warren; Kit Tse, Yee; Ping Tang, Sheng; Man Lee, Kwong; Guo, Xia; Qin, Lin; Chun Yiu Cheng, Jack
2003-09-15
A cross-sectional study of anthropometric parameters in adolescent idiopathic scoliosis (AIS). To compare anthropometric parameters and growth pattern of AIS girls versus normal controls during peri-puberty. Abnormal pattern of growth has been reported in AIS patients. The sequential changes of growth and the correlation with curve severity have not been properly studied. Five hundred ninety-eight AIS girls and 307 healthy girls entered the study. Weight, height, body mass index (BMI), arm span, sitting height, and leg length were determined using standard techniques. Height and sitting height were adjusted by using the greatest Cobb angle to correct for spinal deformity (Bjure's formula). Puberty was graded by Tanner's staging. AIS girls had significantly shorter height (P = 0.001), corrected height (P = 0.005), arm span (P = 0.022), sitting height (P = 0.005) and leg length (P = 0.004) than the controls at pubertal stage I. From pubertal stages II through V, corrected height (P
Nutritional risk and anthropometric evaluation in pediatric liver transplantation.
Zamberlan, Patrícia; Leone, Cláudio; Tannuri, Uenis; Carvalho, Werther Brunow de; Delgado, Artur Figueiredo
2012-12-01
To analyze the nutritional status of pediatric patients after orthotopic liver transplantation and the relationship with short-term clinical outcome. Anthropometric evaluations of 60 children and adolescents after orthotopic liver transplantation, during the first 24 hours in a tertiary pediatric intensive care unit. Nutritional status was determined from the Z score for the following indices: weight/age height/age or length/age, weight/height or weight/length, body mass index/age, arm circumference/age and triceps skinfold/age. The severity of liver disease was evaluated using one of the two models which was adequated to the patients' age: 1. Pediatric End-stage Liver Disease, 2. Model for End-Stage Liver Disease. We found 50.0% undernutrition by height/age; 27.3% by weight/age; 11.1% by weight/height or weight/ length; 10.0% by body mass index/age; 61.6% by arm circumference/age and 51.0% by triceps skinfold/age. There was no correlation between nutritional status and Pediatric End-stage Liver Disease or mortality. We found a negative correlation between arm circumference/age and length of hospitalization. Children with chronic liver diseases experience a significant degree of undernutrition, which makes nutritional support an important aspect of therapy. Despite the difficulties in assessment, anthropometric evaluation of the upper limbs is useful to evaluate nutritional status of children before or after liver transplantation.
Exciton Transport Simulations in Phenyl Cored Thiophene Dendrimers
NASA Astrophysics Data System (ADS)
Kim, Kwiseon; Erkan Kose, Muhammet; Graf, Peter; Kopidakis, Nikos; Rumbles, Garry; Shaheen, Sean E.
2009-03-01
Phenyl cored 3-arm and 4-arm thiophene dendrimers are promising materials for use in photovoltaic devices. It is important to understand the energy transfer mechanisms in these molecules to guide the synthesis of novel dendrimers with improved efficiency. A method is developed to estimate the exciton diffusion lengths for the dendrimers and similar chromophores in amorphous films. The approach exploits Fermi's Golden Rule to estimate the energy transfer rates for an ensemble of bimolecular complexes in random orientations. Using Poisson's equation to evaluate Coulomb integrals led to efficient calculation of excitonic couplings between the transition densities. Monte-Carlo simulations revealed the dynamics of energy transport in the dendrimers. Experimental exciton diffusion lengths of the dendrimers range 10 ˜ 20 nm, increasing with the size of the dendrimer. Simulated diffusion lengths correlate well with experiments. The chemical structure of the chromophore, the shape of the transition densities and the exciton lifetime are found to be the most important factors that determine the exciton diffusion length in amorphous films.
Experimental and numerical study of a dual configuration for a flapping tidal current generator.
Kim, Jihoon; Quang Le, Tuyen; Hwan Ko, Jin; Ebenezer Sitorus, Patar; Hartarto Tambunan, Indra; Kang, Taesam
2015-07-30
In this study, we conduct experimental and consecutive numerical analyses of a flapping tidal current generator with a mirror-type dual configuration with front-swing and rear-swing flappers. An experimental analysis of a small-scale prototype is conducted in a towing tank, and a numerical analysis is conducted by means of two-dimensional computational fluid dynamics simulations with an in-house code. An experimental study with a controller to determine the target arm angle shows that the resultant arm angle is dependent on the input arm angle, the frequency, and the applied load, while a high pitch is obtained simply with a high input arm angle. Through a parametric analysis conducted while varying these factors, a high applied load and a high input arm angle were found to be advantageous. Moreover, the optimal reduced frequency was found to be 0.125 in terms of the power extraction. In consecutive numerical investigations with the kinematics selected from the experiments, it was found that a rear-swing flapper contributes to the total amount of power more than a front-swing flapper with a distance of two times the chord length and with a 90° phase difference between the two. The high contribution stems from the high power generated by the rear-swing flapper, which mimics the tail fin movement of a dolphin along a flow, compared to a plunge system or a front-swing system, which mimics the tail fin movement of a dolphin against a flow. It is also due to the fact that the shed vorticities of the front-swing flapper slightly affect negatively or even positively the power performance of the rear-swing system at a given distance and phase angle.
Karyotype variation in cultivars and spontaneous cocoa mutants (Theobroma cacao L.).
Figueiredo, G S F; Melo, C A F; Souza, M M; Araújo, I S; Zaidan, H A; Pires, J L; Ahnert, D
2013-10-18
Four mutant cocoa accessions with morphological changes and a cultivar sample were karyomorphologically characterized. Slides were prepared by enzymatic digestion of the root meristem and squashed in 45% acetic acid, followed by 2% Giemsa staining. The chromosome number of 2n = 20 was seen in all accessions. The karyotype formula for Cacau Comum and Cacau Rui was 2n = 20m. Submetacentric chromosomes were observed in Cacau Pucala and Cacau Jaca, both with 2n = 18m + 2sm, but the karyotype formula for Cacau Sem Vidro was 2n = 16m + 4sm. Satellites were located on the long arm of the 1st and 2nd chromosome pairs of Cacau Comum, whereas Cacau Pucala had satellites on the 6th chromosome pair. Greater karyotypic variation in Cacau Sem Vidro was found, whose 1st and 2nd chromosome pairs had satellites on the long arm and 6th and 10th pairs had satellites on the short arm. Analysis revealed a lower average chromosome length in Cacau Comum (1.53 ± 0.026 µm) and a higher length in Cacau Sem Vidro (2.26 ± 0.038 µm). ANOVA revealed significant difference (P < 0.01) for the average chromosome length and the length of chromosome pairs within and between accessions. The average chromosome lengths of mutants of Cacau Rui and Cacau Jaca were not statistically different by the Tukey test at 5% probability. The karyotypic diversity observed in this study is not necessarily associated with the changing character of the accessions analyzed, but may reflect the genetic variation observed in Theobroma cacao.
Gumieiro, David Nicoletti; Murino Rafacho, Bruna Paola; Buzati Pereira, Bruna Letícia; Cavallari, Karelin Alvisi; Tanni, Suzana Erico; Azevedo, Paula Schmidt; Polegato, Bertha Furlan; Mamede Zornoff, Leonardo Antonio; Dinhane, Daniel Innocenti; Innocenti Dinhane, Kandir Genésio; Cação Pereira, Gilberto José; de Paiva, Sergio Alberto Rupp; Minicucci, Marcos Ferreira
2015-01-01
The aim of this study was to evaluate the association between serum levels of 25(OH) vitamin D3 with midupper arm muscle circumference (MUAMC), handgrip strength and length of hospital stay (LOS) after hip fracture. In total, 102 consecutive patients with hip fracture over the age of 65 were admitted to the orthopedic unit and prospectively evaluated. All of the patients were treated according to specific protocols depending on the type of fracture. Anthropometric measurements and handgrip strength were performed, and blood samples were taken for serum biochemistry and 25(OH) vitamin D3 analysis within the first 72 h of admission. All of the patients were followed during their hospital stay, and the length of stay was recorded. Of the patients, two were excluded because of pathologic fractures. In total, 100 patients with a mean age of 80 ± 7 y were included in the analysis. Among these patients, 73% were female, and 37% had vitamin D deficiency. The median LOS was 7 (5-11) d. Patients with vitamin D deficiency had lower handgrip strength in univariate analysis. In the multiple linear regression analysis with robust standard error, serum vitamin D levels adjusted by age and sex were associated with handgrip strength but not with MUAMC and LOS after hip fracture. In conclusion, vitamin D serum levels were associated with handgrip strength but not with muscle mass or length of hospital stay after hip fracture. Copyright © 2015 Elsevier Inc. All rights reserved.
Goodbred, Steven L.; Leiker, Thomas J.; Patiño, Reynaldo; Jenkins, Jill A.; Denslow, Nancy D.; Orsak, Erik; Rosen, Michael R.
2007-01-01
The U.S. Geological Survey, in cooperation with the U.S. Fish and Wildlife Service, National Park Service, Bureau of Reclamation, and Nevada Department of Wildlife, collected and assessed data to determine the general health and reproductive status of common carp (Cyprinus carpio) at two study areas in Lake Mead, Nevada, during May 1999-May 2000. These data will form the basis of interpretations and provide a comparison for continuing studies on the health of the ecosystem in Lake Mead. One study area, Las Vegas Bay, is in the western part of Lake Mead. Las Vegas Bay receives inflows from Las Vegas Wash, which is predominantly tertiary-treated wastewater effluent, and to a lesser extent stormwater runoff from Las Vegas, Henderson, and other nearby communities, and from ground water underlying Las Vegas Valley. The other study area, Overton Arm, is in the northern extent of Lake Mead. Overton Arm receives inflow from the Virgin and Muddy Rivers, which historically are not influenced by wastewater effluent. Both sexes of common carp were collected bimonthly for 12 months using boat-mounted electrofishing gear (a direct electric current is used to temporarily immobilize fish for capture) to determine their health and reproductive status and any relation between these factors and environmental contaminants. This report presents fish tissue chemistry, organic chemical compound concentrations, and biomarker data for 83 male common carp collected from Las Vegas Bay, similar organic chemistry results for 15 male common carp, and similar biomarker measures for 80 male common carp collected from Overton Arm. Tissue chemistry results also are presented for 16 female common carp and biomarker measures for 79 female common carp collected from Las Vegas Bay, and tissue chemistry results for 15 female common carp and biomarker measures for 81 female common carp collected from Overton Arm. Thirty-three organic chemical compounds plus total concentrations for four groups of compounds (chlordanes, polychlorinated biphenyls [PCBs], brominated diphenyl ethers [BDEs], and triclosans) were analyzed from extracts of whole-body tissue using gas chromatography/mass spectrometry in male common carp from Las Vegas Bay during May 1999 through May 2000. All 33 compounds were detected in at least one sample of whole-body tissue from male common carp collected in Las Vegas Bay. In Overton Arm, 37 organic compounds plus total concentrations of three groups of compounds (PCBs, BDEs, and triclosans) were analyzed in male common carp where 20 (54 percent) of the compounds were detected. Sixteen of the 33 compounds detected in male common carp from Las Vegas Bay and 10 compounds detected in males from Overton Arm have the potential to disrupt the endocrine system in fish in Lake Mead. During May and June 1999, the mean concentration of all organic compounds detected in male common carp was 670 micrograms per kilogram from Las Vegas Bay and 109 micrograms per kilogram from Overton Arm. Twenty-seven organic compounds plus total PCBs were analyzed from extracts of whole-body tissue in female common carp collected in Las Vegas Bay and Overton Arm during May 1999. Twenty-four (86 percent) of these compounds were detected in at least one sample of whole-body tissue from female common carp collected from Las Vegas Bay while 10 (36 percent) chemical compounds were detected in female common carp from Overton Arm during that same period. Median concentrations of all chemical compounds were higher in female common carp from Las Vegas Bay compared to those collected from Overton Arm except Dacthal (DCPA), which was similar between sites. Biomarker measures obtained for male and female common carp include gonadosomatic index (percentage of gonad weight to total body weight), plasma vitellogenin (a phospholipid protein normally produced by female common carp and other oviparous fish), and condition factor [body weight/(fork length)3]. Biomarker measures for male c
100-m Breaststroke Swimming Performance in Youth Swimmers: The Predictive Value of Anthropometrics.
Sammoud, Senda; Nevill, Alan Michael; Negra, Yassine; Bouguezzi, Raja; Chaabene, Helmi; Hachana, Younés
2018-03-16
This study aimed to estimate the optimal body size, limb segment length, and girth or breadth ratios of 100-m breaststroke performance in youth swimmers. In total, 59 swimmers [male: n = 39, age = 11.5 (1.3) y; female: n = 20, age = 12.0 (1.0) y] participated in this study. To identify size/shape characteristics associated with 100-m breaststroke swimming performance, we computed a multiplicative allometric log-linear regression model, which was refined using backward elimination. Results showed that the 100-m breaststroke performance revealed a significant negative association with fat mass and a significant positive association with the segment length ratio (arm ratio = hand length/forearm length) and limb girth ratio (girth ratio = forearm girth/wrist girth). In addition, leg length, biacromial breadth, and biiliocristal breadth revealed significant positive associations with the 100-m breaststroke performance. However, height and body mass did not contribute to the model, suggesting that the advantage of longer levers was limb-specific rather than a general whole-body advantage. In fact, it is only by adopting multiplicative allometric models that the previously mentioned ratios could have been derived. These results highlighted the importance of considering anthropometric characteristics of youth breaststroke swimmers for talent identification and/or athlete monitoring purposes. In addition, these findings may assist orienting swimmers to the appropriate stroke based on their anthropometric characteristics.
A comparison of lead lengths for mini-fyke nets to sample age-0 gar species
Long, James M.; Snow, Richard A.; Patterson, Chas P.
2016-01-01
Mini-fyke nets are often used to sample small-bodied fishes in shallow (<1 m depth) water, especially in vegetated shoreline habitats where seines are ineffective. Recent interest in gar (Lepisosteidae) ecology and conservation led us to explore the use of mini-fyke nets to capture age-0 gar and specifically how capture is affected by lead length of the fyke net. In the summers of 2012, 2013, and 2015, mini-fyke nets with two different lead lengths (4.57 m and 9.14 m) were set at random sites in backwaters and coves of the Red River arm of Lake Texoma, Oklahoma. Mean CPUE (catch-per-unit-effort; number per net night) was significantly lower for mini-fyke nets with short leads (0.52) compared to those with long leads (1.51). Additionally, Spotted Gar (Lepisosteus oculatus) were captured at a higher rate than the other three gar species present in Lake Texoma, although this could have been an artifact of sampling location. We found that differences in length-frequency of captured gar between gear types were nearly significant, with total length ranging from 47mm to 590mm. Mini-fyke nets with longer leads increased the efficiency of sampling for age-0 gar by increasing catch rate without affecting estimates of other population parameters and appear to be useful for this purpose.
CHARACTERISTICS OF SPIRAL ARMS IN LATE-TYPE GALAXIES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Honig, Z. N.; Reid, M. J., E-mail: mreid@cfa.harvard.edu
2015-02-10
We have measured the positions of large numbers of H II regions in four nearly face-on, late-type, spiral galaxies: NGC 628 (M74), NGC 1232, NGC 3184, and NGC 5194 (M51). Fitting log-periodic spiral models to segments of each arm yields local estimates of spiral pitch angle and arm width. While pitch angles vary considerably along individual arms, among arms within a galaxy, and among galaxies, we find no systematic trend with galactocentric distance. We estimate the widths of the arm segments from the scatter in the distances of the H II regions from the spiral model. All major arms in these galaxies show spiralmore » arm width increasing with distance from the galactic center, similar to the trend seen in the Milky Way. However, in the outermost parts of the galaxies, where massive star formation declines, some arms reverse this trend and narrow. We find that spiral arms often appear to be composed of segments of ∼5 kpc length, which join to form kinks and abrupt changes in pitch angle and arm width; these characteristics are consistent with properties seen in the large N-body simulations of D'Onghia et al. and others.« less
Furniture dimensions and postural overload for schoolchildren's head, upper back and upper limbs.
Batistão, Mariana Vieira; Sentanin, Anna Cláudia; Moriguchi, Cristiane Shinohara; Hansson, Gert-Åke; Coury, Helenice Jane Cote Gil; de Oliveira Sato, Tatiana
2012-01-01
The aim of this study was to evaluate how the fixed furniture dimensions match with students' anthropometry and to describe head, upper back and upper limbs postures and movements. Evaluation was performed in 48 students from a Brazilian state school. Furniture dimensions were measured with metric tape, movements and postures by inclinometers (Logger Tecknologi, Åkarp, Sweden). Seat height was high for 21% and low for 36% of the students; seat length was short for 45% and long for 9% and table height was high for 53% and low for 28%. Regression analysis showed that seat/popliteal height quotient is explained by 90th percentile of upper back inclination (β=0.410) and 90th percentile of right upper arm elevation (β=-0.293). For seat/thigh length quotient the significant variables were 90th percentile of upper back velocity (β=-0.282) and 90th percentile of right upper arm elevation (β=0.410). This study showed a relationship between furniture mismatch and postural overload. When the seat height is low students increase upper back left inclination and right upper arm elevation; when the seat is short students decrease the upper back flexion velocity and increase right upper arm elevation.
An interlaminar tension strength specimen
NASA Technical Reports Server (NTRS)
Jackson, Wade C.; Martin, Roderick H.
1992-01-01
This paper describes a technique to determine interlaminar tension strength, sigma(sub 3c) of a fiber reinforced composite material using a curved beam. The specimen was a unidirectional curved beam, bent 90 degrees, with straight arms. Attached to each arm was a hinged loading mechanism which was held by the grips of a tensile testing machine. Geometry effects of the specimen, including the effects of loading arm length, inner radius, thickness, and width, were studied. The data sets fell into two categories: low strength corresponding to a macroscopic flaw related failure and high strength corresponding to a microscopic flaw related failure. From the data available, the loading arm length had no effect on sigma(sub 3c). The inner radius was not expected to have a significant effect on sigma(sub 3c), but this conclusion could not be confirmed because of differences in laminate quality for each curve geometry. The thicker specimens had the lowest value of sigma(sub 3c) because of poor laminate quality. Width was found to affect the value of sigma(sub 3c) only slightly. The wider specimens generally had a slightly lower strength since more material was under high stress, and hence, had a larger probability of containing a significant flaw.
Torsionally rigid support apparatus for marine seismic transducer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Myers, W.J.; Cole, J.H.
1989-11-14
This patent describes apparatus for supporting a marine seismic transducer from a vessel. It comprises: an elongated substantially rigid towing arm; a connector means for connecting the transducer to a lower end of the towing arm; a swivel member which is secured to the vessel and is pivotable about a generally horizontal first axis transverse to a length of the vessel; and a support means for pivotally connecting an upper end of the towing arm to the swivel member. The support means being pivotal relative to the swivel member about a second axis transverse to a longitudinal axis of themore » towing arm. The support means being substantially rigid so as to prevent any substantial rotation of the towing arm about its the longitudinal axis.« less
Muscle short-range stiffness can be used to estimate the endpoint stiffness of the human arm
Hu, Xiao; Murray, Wendy M.
2011-01-01
The mechanical properties of the human arm are regulated to maintain stability across many tasks. The static mechanics of the arm can be characterized by estimates of endpoint stiffness, considered especially relevant for the maintenance of posture. At a fixed posture, endpoint stiffness can be regulated by changes in muscle activation, but which activation-dependent muscle properties contribute to this global measure of limb mechanics remains unclear. We evaluated the role of muscle properties in the regulation of endpoint stiffness by incorporating scalable models of muscle stiffness into a three-dimensional musculoskeletal model of the human arm. Two classes of muscle models were tested: one characterizing short-range stiffness and two estimating stiffness from the slope of the force-length curve. All models were compared with previously collected experimental data describing how endpoint stiffness varies with changes in voluntary force. Importantly, muscle properties were not fit to the experimental data but scaled only by the geometry of individual muscles in the model. We found that force-dependent variations in endpoint stiffness were accurately described by the short-range stiffness of active arm muscles. Over the wide range of evaluated arm postures and voluntary forces, the musculoskeletal model incorporating short-range stiffness accounted for 98 ± 2, 91 ± 4, and 82 ± 12% of the variance in stiffness orientation, shape, and area, respectively, across all simulated subjects. In contrast, estimates based on muscle force-length curves were less accurate in all measures, especially stiffness area. These results suggest that muscle short-range stiffness is a major contributor to endpoint stiffness of the human arm. Furthermore, the developed model provides an important tool for assessing how the nervous system may regulate endpoint stiffness via changes in muscle activation. PMID:21289133
Assessment by bioimpedance of forearm cell mass: a new approach to calibration.
Pietrobelli, A; Nuñez, C; Zingaretti, G; Battistini, N; Morini, P; Wang, Z M; Yasumura, S; Heymsfield, S B
2002-08-01
Changes in skeletal muscle mass are involved in several important clinical disorders including sarcopenia and obesity. Unlike body fat, skeletal muscle is difficult to quantify in vivo, particularly without highly specialized equipment. The present study had a two-fold aim: to develop a regional (40)K counter for non-invasively estimating cell mass in the arm, mainly skeletal muscle cell mass, without radiation exposure; and to test the hypothesis that cell mass in the arm is highly correlated with electrical impedance after adjusting for the arm's length. Forearm cell mass was estimated using a rectangular lead-shielded (40)K counter with 4-NaI crystals; impedance of the arm was measured at multiple frequencies using a segmental bioimpedance analysis (BIA) system. The system's within- and between-day coefficient of variation (CV) for (40)K-derived elemental potassium averaged 1.8+/-1.3 and 5.8+/-1.2%, respectively. The corresponding BIA system's CVs were 1.0+/-0.4 and 2.1+/-1.0%, respectively. Participants in the study were 15 healthy adults (eight females, seven males; age 39+/-2.8 y, BMI 22.9+/-4.5 kg/m(2)). The right arm's K (5.2+/-1.7 g) was highly correlated with length-adjusted impedance (r(2)=0.81, 0.82, and 0.83 for 5, 50 and 300 kHz, respectively; all P<0.001); multiple regression analysis showed no additional improvement by adding age or sex to the prediction models. These results demonstrate the feasibility of calibrating BIA-measured electrical properties of the arm against estimates of arm cell mass, mainly of skeletal muscle, obtained by regional (40)K counting. This simple and practical approach should facilitate the development of BIA-based regional cell mass prediction formulas
Self-Contained Compressed-Flow Generation Device for Use in Making Differential Measurements
NASA Technical Reports Server (NTRS)
England, John Dwight (Inventor); Kelley, Anthony R. (Inventor); Cronise, Raymond J. (Inventor)
2014-01-01
A device used in making differential measurements of a flow includes a flow obstruction and a support arm. The flow obstruction's forward portion is a nose cone. The flow obstruction's aft portion is coupled to the nose cone. The support arm's first end is coupled to an exterior wall of a conduit, and its second end is coupled to the forward portion of the flow obstruction. The support arm positions the flow obstruction in the conduit such that a flow region is defined around its nose cone, and such that the support arm's first and second end are separated from one another with respect to a length dimension of the conduit. Measurement ports are provided in the support arm and flow obstruction. Manifolds extending through the flow obstruction and support arm couple the ports to points at the exterior wall of the conduit.
Gritsenko, Valeriya; Hardesty, Russell L; Boots, Mathew T; Yakovenko, Sergiy
2016-01-01
Neural control of movement can only be realized though the interaction between the mechanical properties of the limb and the environment. Thus, a fundamental question is whether anatomy has evolved to simplify neural control by shaping these interactions in a beneficial way. This inductive data-driven study analyzed the patterns of muscle actions across multiple joints using the musculoskeletal model of the human upper limb. This model was used to calculate muscle lengths across the full range of motion of the arm and examined the correlations between these values between all pairs of muscles. Musculoskeletal coupling was quantified using hierarchical clustering analysis. Muscle lengths between multiple pairs of muscles across multiple postures were highly correlated. These correlations broadly formed two proximal and distal groups, where proximal muscles of the arm were correlated with each other and distal muscles of the arm and hand were correlated with each other, but not between groups. Using hierarchical clustering, between 11 and 14 reliable muscle groups were identified. This shows that musculoskeletal anatomy does indeed shape the mechanical interactions by grouping muscles into functional clusters that generally match the functional repertoire of the human arm. Together, these results support the idea that the structure of the musculoskeletal system is tuned to solve movement complexity problem by reducing the dimensionality of available solutions.
The effects of the arm swing on biomechanical and physiological aspects of roller ski skating.
Hegge, Ann Magdalen; Ettema, Gertjan; de Koning, Jos J; Rognstad, Asgeir Bakken; Hoset, Martin; Sandbakk, Øyvind
2014-08-01
This study analyzed the biomechanical and physiological effects of the arm swing in roller ski skating, and compared leg-skating (i.e. ski skating without poles) using a pronounced arm swing (SWING) with leg-skating using locked arms (LOCKED). Sixteen elite male cross-country skiers performed submaximal stages at 10, 15 and 20kmh(-1) on a 2% inclined treadmill in the two techniques. SWING demonstrated higher peak push-off forces and a higher force impulse at all speeds, but a longer cycle length only at the highest speed (all P<.05), indicating a lower force effectiveness with SWING at the two lowest speeds. Additionally, the flexion-extension movement in the lower limbs was more pronounced for SWING. Oxygen uptake was higher for SWING at the two lowest speeds (both P<.05) without any differences in blood lactate. At the highest speed, oxygen uptake did not differ between SWING and LOCKED, but the RER, blood lactate and ventilation were lower with SWING (all P<.05). Taken together, these results demonstrate that utilizing the arm swing in roller ski skating increases the ski forces and aerobic energy cost at low and moderate speeds, whereas the greater forces at high speed lead to a longer cycle length and smaller anaerobic contribution. Copyright © 2014 Elsevier B.V. All rights reserved.
Caçola, Priscila; Gabbard, Carl
2012-04-01
This study examined age-related characteristics associated with tool use in the perception and modulation of peripersonal and extrapersonal space. Seventy-six (76) children representing age groups 7-, 9-, 11 years and 36 adults were presented with two experiments using an estimation of reach paradigm involving arm and tool conditions and a switch-block of the opposite condition. Experiment 1 tested Arm and Tool (20 cm length) estimation and found a significant effect for Age, Space, and an Age × Space interaction (ps < 0.05). Both children and adults were less accurate in extrapersonal space, indicating an overestimation bias. Interestingly, the adjustment period during the switch-block condition was immediate and similar across age. Experiment 2 was similar to Experiment 1 with the exception of using a 40-cm-length tool. Results also revealed an age effect and a difference in Space (ps < 0.05), however, participants underestimated. Speculatively, participants were less confident when presented with a longer tool, even though the adjustment period with both tool lengths was similar. Considered together, these results hint that: (1) children as young as 6 years of age are capable of being as accurate when estimating reach with a tool as they are with their arm, (2) the adjustment period associated with extending and retracting spaces is immediate rather than gradual, and (3) tool length influences estimations of reach.
Evaluation of arm-leg coordination in flat breaststroke.
Chollet, D; Seifert, L; Leblanc, H; Boulesteix, L; Carter, M
2004-10-01
This study proposes a new method to evaluate arm-leg coordination in flat breaststroke. Five arm and leg stroke phases were defined with a velocity-video system. Five time gaps quantified the time between arm and leg actions during three paces of a race (200 m, 100 m and 50 m) in 16 top level swimmers. Based on these time gaps, effective glide, effective propulsion, effective leg insweep and effective recovery were used to identify the different stroke phases of the body. A faster pace corresponded to increased stroke rate, decreased stroke length, increased propulsive phases, shorter glide phases, and a shorter T1 time gap, which measured the effective body glide. The top level swimmers showed short time gaps (T2, T3, T4, measuring the timing of arm-leg recoveries), which reflected the continuity in arm and leg actions. The measurement of these time gaps thus provides a pertinent evaluation of swimmers' skill in adapting their arm-leg coordination to biomechanical constraints.
Trunnionosis: Does Head Size Affect Fretting and Corrosion in Total Hip Arthroplasty?
Del Balso, Christopher; Teeter, Matthew G; Tan, Sok Chuen; Howard, James L; Lanting, Brent A
2016-10-01
Wear and tribocorrosion at the modular head-neck taper interface may be a cause of failure in metal-on-polyethylene total hip arthroplasty (THA). The present investigation endeavored to elucidate the effect of femoral head diameter on fretting and corrosion in retrieved head-neck tapers. A retrieval analysis of THA prostheses in vivo for a minimum of 1 year was performed. Twenty-three femoral heads of 32-mm diameter were matched with 28-mm heads based on time in vivo and head length (-3 mm to +8 mm). All included implants featured a single taper design from a single manufacturer. Fretting and corrosion damage scoring was performed for each implant under stereomicroscopic visualization. Head diameter was observed to affect fretting (P = .01), with 32-mm femoral heads exhibiting greater total fretting scores than 28-mm heads. Fretting damage was greatest (P = .01) in the central concentric zone of the femoral head bore tapers, regardless of head diameter, length, or stem offset. No significant effect on total corrosion scores was observed for any head or stem variable. Retrieved implant total corrosion scores were positively correlated (ρ = 0.51, P < .001) with implantation time. Increased femoral head diameter in THA may produce greater fretting damage owing to and increased head-neck moment arm. There is no associated increase in corrosion with 28-mm and 32-mm heads of this taper design. The longer a THA prosthesis is implanted, the greater the risk of damage due to corrosion. Copyright © 2016 Elsevier Inc. All rights reserved.
Raichlen, David A; Armstrong, Hunter; Lieberman, Daniel E
2011-03-01
The endurance running (ER) hypothesis suggests that distance running played an important role in the evolution of the genus Homo. Most researchers have focused on ER performance in modern humans, or on reconstructing ER performance in Homo erectus, however, few studies have examined ER capabilities in other members of the genus Homo. Here, we examine skeletal correlates of ER performance in modern humans in order to evaluate the energetics of running in Neandertals and early Homo sapiens. Recent research suggests that running economy (the energy cost of running at a given speed) is strongly related to the length of the Achilles tendon moment arm. Shorter moment arms allow for greater storage and release of elastic strain energy, reducing energy costs. Here, we show that a skeletal correlate of Achilles tendon moment arm length, the length of the calcaneal tuber, does not correlate with walking economy, but correlates significantly with running economy and explains a high proportion of the variance (80%) in cost between individuals. Neandertals had relatively longer calcaneal tubers than modern humans, which would have increased their energy costs of running. Calcaneal tuber lengths in early H. sapiens do not significantly differ from those of extant modern humans, suggesting Neandertal ER economy was reduced relative to contemporaneous anatomically modern humans. Endurance running is generally thought to be beneficial for gaining access to meat in hot environments, where hominins could have used pursuit hunting to run prey taxa into hyperthermia. We hypothesize that ER performance may have been reduced in Neandertals because they lived in cold climates. Copyright © 2011 Elsevier Ltd. All rights reserved.
Apparatus and method for performing two-frequency interferometry
Johnston, Roger G.
1990-01-01
The present apparatus includes a two-frequency, Zeeman-effect laser and matched, doubly refracting crystals in the construction of an accurate interferometer. Unlike other interferometric devices, the subject invention exhibits excellent phase stability owing to the use of single piece means for producing parallel interferometer arms, making the interferometer relatively insensitive to thermal and mechanical instabilities. Interferometers respond to differences in optical path length between their two arms. Unlike many interferometric techniques, which require the measurement of the location of interference fringes in a brightly illuminated background, the present invention permits the determination of the optical path length difference by measuring the phase of an electronic sine wave. The present apparatus is demonstrated as a differential thermooptic spectrometer for measuring differential optical absorption simply and accurately which is but one of many applications therefor. The relative intensities of the heating beams along each arm of the interferometer can be easily adjusted by observing a zero phase difference with identical samples when this condition is obtained.
Apparatus and method for performing two-frequency interferometry
Johnston, R.G.
1988-01-25
The present apparatus includes a two-frequency, Zeeman Effect laser and matched, doubly refracting crystals in the construction of an accurate interferometer. Unlike other interferometric devices, the subject invention exhibits excellent phase stability owing to the use of single piece means for producing parallel interferometer arms, making the interferometer relatively insensitive to thermal and mechanical instabilities. Interferometers respond to differences in optical path length between their two arms. Unlike many interferometric techniques, which require the measurement of the location of interference fringes in a brightly illuminated background, the present invention permits the determination of the optical path length difference by measuring the phase of an electronic sine wave. The present apparatus is demonstrated as a differential thermooptic spectrometer for measuring differential optical absorption simply and accurately which is but one of many applications therefor. The relative intensities of the heating beams along each arm of the interferometer can be easily adjusted by observing a zero phase difference with identical samples when this condition is obtained. 6 figs.
Multi-pose system for geometric measurement of large-scale assembled rotational parts
NASA Astrophysics Data System (ADS)
Deng, Bowen; Wang, Zhaoba; Jin, Yong; Chen, Youxing
2017-05-01
To achieve virtual assembly of large-scale assembled rotational parts based on in-field geometric data, we develop a multi-pose rotative arm measurement system with a gantry and 2D laser sensor (RAMSGL) to measure and provide the geometry of these parts. We mount a 2D laser sensor onto the end of a six-jointed rotative arm to guarantee the accuracy and efficiency, combine the rotative arm with a gantry to measure pairs of assembled rotational parts. By establishing and using the D-H model of the system, the 2D laser data is turned into point clouds and finally geometry is calculated. In addition, we design three experiments to evaluate the performance of the system. Experimental results show that the system’s max length measuring deviation using gauge blocks is 35 µm, max length measuring deviation using ball plates is 50 µm, max single-point repeatability error is 25 µm, and measurement scope is from a radius of 0 mm to 500 mm.
Learning the inverse kinetics of an octopus-like manipulator in three-dimensional space.
Giorelli, M; Renda, F; Calisti, M; Arienti, A; Ferri, G; Laschi, C
2015-05-13
This work addresses the inverse kinematics problem of a bioinspired octopus-like manipulator moving in three-dimensional space. The bioinspired manipulator has a conical soft structure that confers the ability of twirling around objects as a real octopus arm does. Despite the simple design, the soft conical shape manipulator driven by cables is described by nonlinear differential equations, which are difficult to solve analytically. Since exact solutions of the equations are not available, the Jacobian matrix cannot be calculated analytically and the classical iterative methods cannot be used. To overcome the intrinsic problems of methods based on the Jacobian matrix, this paper proposes a neural network learning the inverse kinematics of a soft octopus-like manipulator driven by cables. After the learning phase, a feed-forward neural network is able to represent the relation between manipulator tip positions and forces applied to the cables. Experimental results show that a desired tip position can be achieved in a short time, since heavy computations are avoided, with a degree of accuracy of 8% relative average error with respect to the total arm length.
Alam, Syed Benazir; Reade, Ron; Theilmann, Jane; Rochon, D'Ann
2017-12-01
Cucumber necrosis virus (CNV) is a T = 3 icosahedral virus with a (+)ssRNA genome. The N-terminal CNV coat protein arm contains a conserved, highly basic sequence ("KGRKPR"), which we postulate is involved in RNA encapsidation during virion assembly. Seven mutants were constructed by altering the CNV "KGRKPR" sequence; the four basic residues were mutated to alanine individually, in pairs, or in total. Virion accumulation and vRNA encapsidation were significantly reduced in mutants containing two or four substitutions and virion morphology was also affected, where both T = 1 and intermediate-sized particles were produced. Mutants with two or four substitutions encapsidated significantly greater levels of truncated RNA than that of WT, suggesting that basic residues in the "KGRKPR" sequence are important for encapsidation of full-length CNV RNA. Interestingly, "KGRKPR" mutants also encapsidated relatively higher levels of host RNA, suggesting that the "KGRKPR" sequence also contributes to selective encapsidation of CNV RNA. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
Talia, Adrian J; Coetzee, Cassandra; Tirosh, Oren; Tran, Phong
2018-01-08
Total hip arthroplasty is one of the most commonly performed surgical procedures worldwide. There are a number of surgical approaches for total hip arthroplasty and no high-level evidence supporting one approach over the other. Each approach has its unique benefits and drawbacks. This trial aims to directly compare the three most common surgical approaches for total hip arthroplasty. This is a single-centre study conducted at Western Health, Melbourne, Australia; a large metropolitan centre. It is a pragmatic, parallel three-arm, randomised controlled trial. Sample size will be 243 participants (81 in each group). Randomisation will be secure, web-based and managed by an independent statistician. Patients and research team will be blinded pre-operatively, but not post-operatively. Intervention will be either direct anterior, lateral or posterior approach for total hip arthroplasty, and the three arms will be directly compared. Participants will be aged over 18 years, able to provide informed consent and recruited from our outpatients. Patients who are having revision surgery or have indications for hip replacement other than osteoarthritis (i.e., fracture, malignancy, development dysplasia) will be excluded from the trial. The Oxford Hip Score will be determined for patients pre-operatively and 6 weeks, 6, 12 and 24 months post-operatively. The Oxford Hip Score at 24 months will be the primary outcome measure. Secondary outcome measures will be dislocation, infection, intraoperative and peri-prosthetic fracture rate, length of hospital stay and pain level, reported using a visual analogue scale. Many studies have evaluated approaches for total hip arthroplasty and arthroplasty registries worldwide are now collecting this data. However no study to date has compared these three common approaches directly in a randomised fashion. No trial has used patient-reported outcome measures to evaluate success. This pragmatic study aims to identify differences in patient perception of total hip arthroplasty depending on surgical approach. Australian New Zealand Clinical Trials Registry, ACTRN12617000272392 . Registered on 22 February 2017.
Cloud Size Distributions from Multi-sensor Observations of Shallow Cumulus Clouds
NASA Astrophysics Data System (ADS)
Kleiss, J.; Riley, E.; Kassianov, E.; Long, C. N.; Riihimaki, L.; Berg, L. K.
2017-12-01
Combined radar-lidar observations have been used for almost two decades to document temporal changes of shallow cumulus clouds at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Facility's Southern Great Plains (SGP) site in Oklahoma, USA. Since the ARM zenith-pointed radars and lidars have a narrow field-of-view (FOV), the documented cloud statistics, such as distributions of cloud chord length (or horizontal length scale), represent only a slice along the wind direction of a region surrounding the SGP site, and thus may not be representative for this region. To investigate this impact, we compare cloud statistics obtained from wide-FOV sky images collected by ground-based observations at the SGP site to those from the narrow FOV active sensors. The main wide-FOV cloud statistics considered are cloud area distributions of shallow cumulus clouds, which are frequently required to evaluate model performance, such as routine large eddy simulation (LES) currently being conducted by the ARM LASSO (LES ARM Symbiotic Simulation and Observation) project. We obtain complementary macrophysical properties of shallow cumulus clouds, such as cloud chord length, base height and thickness, from the combined radar-lidar observations. To better understand the broader observational context where these narrow FOV cloud statistics occur, we compare them to collocated and coincident cloud area distributions from wide-FOV sky images and high-resolution satellite images. We discuss the comparison results and illustrate the possibility to generate a long-term climatology of cloud size distributions from multi-sensor observations at the SGP site.
Effect of increasing energy cost on arm coordination in elite sprint swimmers.
Komar, J; Leprêtre, P M; Alberty, M; Vantorre, J; Fernandes, R J; Hellard, P; Chollet, D; Seifert, L
2012-06-01
The purpose of this study was to analyze the changes in stroke parameters, motor organization and swimming efficiency with increasing energy cost in aquatic locomotion. Seven elite sprint swimmers performed a 6×300-m incremental swimming test. Stroke parameters (speed, stroke rate and stroke length), motor organization (arm stroke phases and arm coordination index), swimming efficiency (swimming speed squared and hand speed squared) and stroke index were calculated from aerial and underwater side-view cameras. The energy cost of locomotion was assessed by measuring oxygen consumption and blood lactate. Results showed that the increase in energy cost of locomotion was correlated to an increase in the index of coordination and stroke rate, and a decrease in stroke length (p<.05). Furthermore, indicators of swimming efficiency and stroke index did not change significantly with the speed increments (p<.05), indicating that swimmers did not decrease their efficiency despite the increase in energy cost. In parallel, an increase in the index of coordination IdC and stroke rate were observed, along with a decrease in stroke length, stroke index and hand speed squared with each increment, revealing an adaptation to the fatigue within the 300m. Copyright © 2011 Elsevier B.V. All rights reserved.
Su, Alvin W; McIntosh, Amy L; Schueler, Beth A; Milbrandt, Todd A; Winkler, Jennifer A; Stans, Anthony A; Larson, A Noelle
Intraoperative C-arm fluoroscopy and low-dose O-arm are both reasonable means to assist in screw placement for idiopathic scoliosis surgery. Both using pediatric low-dose O-arm settings and minimizing the number of radiographs during C-arm fluoroscopy guidance decrease patient radiation exposure and its deleterious biological effect that may be associated with cancer risk. We hypothesized that the radiation dose for C-arm-guided fluoroscopy is no less than low-dose O-arm scanning for placement of pedicle screws. A multicenter matched-control cohort study of 28 patients in total was conducted. Fourteen patients who underwent O-arm-guided pedicle screw insertion for spinal fusion surgery in 1 institution were matched to another 14 patients who underwent C-arm fluoroscopy guidance in the other institution in terms of the age of surgery, body weight, and number of imaged spine levels. The total effective dose was compared. A low-dose pediatric protocol was used for all O-arm scans with an effective dose of 0.65 mSv per scan. The effective dose of C-arm fluoroscopy was determined using anthropomorphic phantoms that represented the thoracic and lumbar spine in anteroposterior and lateral views, respectively. The clinical outcome and complications of all patients were documented. The mean total effective dose for the O-arm group was approximately 4 times higher than that of the C-arm group (P<0.0001). The effective dose for the C-arm patients had high variability based on fluoroscopy time and did not correlate with the number of imaged spine levels or body weight. The effective dose of 1 low-dose pediatric O-arm scan approximated 85 seconds of the C-arm fluoroscopy time. All patients had satisfactory clinical outcomes without major complications that required returning to the operating room. Radiation exposure required for O-arm scans can be higher than that required for C-arm fluoroscopy, but it depends on fluoroscopy time. Inclusion of more medical centers and surgeons will better account for the variability of C-arm dose due to distinct patient characteristics, surgeon's preference, and individual institution's protocol. Level III-case-control study.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-17
...-length AUDIT PROCESS transmission contracts, See Note. production and operating agreements and related... production method. 1206.458(c)(1)(iv) and (c)(2)(vi).. Submit arm's-length washing AUDIT PROCESS contracts...). The Secretary is required by various laws to manage mineral resource production from Federal and...
Geramy, Allahyar; Hassanpour, Mehdi; Emadian Razavi, Elham Sadat
2015-03-01
This study sought to assess distal and lateral forces and moments of asymmetric headgears by variable outer bow lengths. Four 3D finite element method (FEM) models of a cervical headgear attached to the maxillary first molars were designed in SolidWorks 2010 software and transferred to ANSYS Workbench ver. 11 software. Models contained the first molars, their periodontal ligament (PDL), cancellous and cortical bones, a mesiodistal slice of the maxillae and the headgear. Models were the same except for the outer bow length in headgears. The headgear was symmetric in model 1. In models 2 to 4, the headgears were asymmetric in length with differences of 5mm, 10mm and 15mm, respectively. A 2.5 N force in horizontal plane was applied and the loading manner of each side of the outer bow was calculated trigonometrically using data from a volunteer. The 15mm difference in outer bow length caused the greatest difference in lateral (=0.21 N) and distal (= 1.008 N) forces and also generated moments (5.044 N.mm). As the difference in outer bow length became greater, asymmetric effects increased. Greater distal force in the longer arm side was associated with greater lateral force towards the shorter arm side and more net yawing moment. A difference range of 1mm to 15 mm of length in cervical headgear can be considered as a safe length of outer bow shortening in clinical use.
Deployment and Simulation of the Astrod-Gw Formation
NASA Astrophysics Data System (ADS)
Wu, An-Ming; Ni, Wei-Tou
2013-01-01
Constellation or formation flying is a common concept in space Gravitational Wave (GW) mission proposals for the required interferometry implementation. The spacecraft of most of these mission proposals go to deep space and many have Earthlike orbits around the Sun. Astrodynamical Space Test of Relativity using Optical Devices optimized for Gravitation Wave detection (ASTROD-GW), Big Bang Observer (BBO) and DECIGO have spacecraft distributed in Earthlike orbits in formation. The deployment of orbit formation is an important issue for these missions. ASTROD-GW is to focus on the goal of detection of GWs. The mission orbits of the three spacecraft forming a nearly equilateral triangular array are chosen to be near the Sun-Earth Lagrange points L3, L4 and L5. The three spacecraft range interferometrically with one another with arm length about 260 million kilometers with the scientific goals including detection of GWs from Massive Black Holes (MBH) and Extreme-Mass-Ratio Black Hole Inspirals (EMRI), and using these observations to find the evolution of the equation of state of dark energy and to explore the co-evolution of MBH with galaxies. In this paper, we review the formation flying for fundamental physics missions, design the preliminary transfer orbits of the ASTROD-GW spacecraft from the separations of the launch vehicles to the mission orbits, and simulate the arm lengths of the triangular formation. From our study, the optimal delta-Vs and propellant ratios of the transfer orbits could be within about 2.5 km/s and 0.55, respectively. From the simulation of the formation for 10 years, the arm lengths of the formation vary in the range 1.73210 ± 0.00015 AU with the arm length differences varying in the range ±0.00025 AU for formation with 1° inclination to the ecliptic plane. This meets the measurement requirements. Further studies on the optimizations of deployment and orbit configurations for a period of 20 years and with inclinations between 1° to 3° are currently ongoing.
A Novel Posture for Better Differentiation Between Parkinson's Tremor and Essential Tremor
Zhang, Bin; Huang, Feifei; Liu, Jun; Zhang, Dingguo
2018-01-01
Due to a lack of reliable non-invasive bio-markers, misdiagnosis between Parkinson's disease and essential tremor is common. Although some assistive engineering approaches have been proposed, little acceptance has been obtained for these methods lack well-studied mechanisms and involve operator-dependent procedures. Aiming at a better differentiation between the two tremor causes, we present a novel posture, termed arm-rested posture, to ameliorate the quality of recorded tremor sequences. To investigate its efficacy, the posture was compared with another common posture, called arm-stretching posture, in fundamental aspects of tremor intensity and dominant frequency. A tremor-affected cohort comprising 50 subjects (PD = 26, ET = 24) with inhomogeneous tremor manifestation were recruited. From each subject, acceleration data of 5 min in terms of each posture were recorded. In the overall process, no operator-dependent procedures, such as data screening, was employed. The differentiation performance of the two postures were assessed by the index of discrimination coefficient and a receiver operating characteristic analysis based on binary logistic regression. The results of the differentiation assessment consistently demonstrate a better performance with the arm-rested posture than with the arm-stretching posture. As a by-product, factors of disease stage (incipient, progressed stage), spectrum estimate (PSD, bispectrum) and recording length (5–300s) were investigated. The significant effect of disease stage was only found in PD in terms of tremor intensity [F(1, 516) = 7.781, P < 0.05]. The bispectrum estimate was found to have better performance than the PSD estimate in extracting dominant frequency in terms of the discrimination coefficient. By extending the recording length, we noticed an increase in the performance of dominant frequency. The best result of the arm-rested posture was obtained with the maximum recording length of 300 s (area under the curve: 0.944, sensitivity: 92%, 1-specificity: 0%, accuracy: 96%), which is better than that of the arm-stretching posture in the same condition (area under the curve: 0.734, sensitivity: 54%, 1-specificity: 12%, accuracy: 72%). Thus, we conclude that the arm-rested posture can assist in improving tremor differentiation between Parkinson's disease and essential tremor and may act as a universal tool to analyze tremor for both clinical and research purpose. PMID:29867328
Effects of wrist tendon vibration on arm tracking in people poststroke.
Conrad, Megan O; Scheidt, Robert A; Schmit, Brian D
2011-09-01
The goal of this study was to evaluate the influence of wrist tendon vibration on a multijoint elbow/shoulder tracking task. We hypothesized that tendon vibration applied at the wrist musculature would improve upper arm tracking performance in chronic stroke survivors through increased, Ia-afferent feedback to the central nervous system (CNS). To test this hypothesis, 10 chronic stroke and 5 neurologically intact subjects grasped the handle of a planar robot as they tracked a target through a horizontal figure-8 pattern. A total of 36 trials were completed by each subject. During the middle trials, 70-Hz tendon vibration was applied at the wrist flexor tendons. Position, velocity, and electromyography data were evaluated to compare the quality of arm movements before, during, and after trials with concurrent vibration. Despite tracking a target that moved at a constant velocity, hand trajectories appeared to be segmented, displaying alternating intervals of acceleration and deceleration. Segments were identifiable in tangential velocity data as single-peaked, bell-shaped speed pulses. When tendon vibration was applied at the wrist musculature, stroke subjects experienced improved tracking performance in that hand path lengths and peak speed variability decreased, whereas movement smoothness increased. These performance improvements were accompanied by decreases in the muscle activity during movement. Possible mechanisms behind improved movement control in response to tendon vibration may include improved sensorimotor integration or improved cortical modulation of spinal reflex activity.
Effects of wrist tendon vibration on arm tracking in people poststroke
Conrad, Megan O.; Scheidt, Robert A.
2011-01-01
The goal of this study was to evaluate the influence of wrist tendon vibration on a multijoint elbow/shoulder tracking task. We hypothesized that tendon vibration applied at the wrist musculature would improve upper arm tracking performance in chronic stroke survivors through increased, Ia-afferent feedback to the central nervous system (CNS). To test this hypothesis, 10 chronic stroke and 5 neurologically intact subjects grasped the handle of a planar robot as they tracked a target through a horizontal figure-8 pattern. A total of 36 trials were completed by each subject. During the middle trials, 70-Hz tendon vibration was applied at the wrist flexor tendons. Position, velocity, and electromyography data were evaluated to compare the quality of arm movements before, during, and after trials with concurrent vibration. Despite tracking a target that moved at a constant velocity, hand trajectories appeared to be segmented, displaying alternating intervals of acceleration and deceleration. Segments were identifiable in tangential velocity data as single-peaked, bell-shaped speed pulses. When tendon vibration was applied at the wrist musculature, stroke subjects experienced improved tracking performance in that hand path lengths and peak speed variability decreased, whereas movement smoothness increased. These performance improvements were accompanied by decreases in the muscle activity during movement. Possible mechanisms behind improved movement control in response to tendon vibration may include improved sensorimotor integration or improved cortical modulation of spinal reflex activity. PMID:21697444
A self-assembled nanoscale robotic arm controlled by electric fields
NASA Astrophysics Data System (ADS)
Kopperger, Enzo; List, Jonathan; Madhira, Sushi; Rothfischer, Florian; Lamb, Don C.; Simmel, Friedrich C.
2018-01-01
The use of dynamic, self-assembled DNA nanostructures in the context of nanorobotics requires fast and reliable actuation mechanisms. We therefore created a 55-nanometer–by–55-nanometer DNA-based molecular platform with an integrated robotic arm of length 25 nanometers, which can be extended to more than 400 nanometers and actuated with externally applied electrical fields. Precise, computer-controlled switching of the arm between arbitrary positions on the platform can be achieved within milliseconds, as demonstrated with single-pair Förster resonance energy transfer experiments and fluorescence microscopy. The arm can be used for electrically driven transport of molecules or nanoparticles over tens of nanometers, which is useful for the control of photonic and plasmonic processes. Application of piconewton forces by the robot arm is demonstrated in force-induced DNA duplex melting experiments.
2009-12-01
MINORITY CHARGE CARRIER DIFFUSION LENGTH IN GALLIUM NITRIDE NANOWIRES USING ELECTRON BEAM INDUCED CURRENT (EBIC) by Chiou Perng Ong December... Gallium Nitride Nanowires Using Electron Beam Induced Current (EBIC) 6. AUTHOR(S) Ong, Chiou Perng 5. FUNDING NUMBERS DMR 0804527 7. PERFORMING...CARRIER DIFFUSION LENGTH IN GALLIUM NITRIDE NANOWIRES USING ELECTRON BEAM INDUCED CURRENT (EBIC) Chiou Perng Ong Major, Singapore Armed Forces B
Behringer, Verena; Stevens, Jeroen M G; Kivell, Tracy L; Neufuss, Johanna; Boesch, Christophe; Hohmann, Gottfried
2016-09-01
Bonobos and chimpanzees are known to differ in various morphological traits, a dichotomy that is sometimes used as an analogy for evolutionary splits during human evolution. The aim of our study was to measure the forearm length of immature and adult bonobos and adult chimpanzees to assess the extent of age-related changes of forearm length in bonobos and sex-dimorphism in bonobos and chimpanzees. As a proxy of somatic growth we measured forearm length of captive bonobos and chimpanzees ranging in age from 1 to 55 years. Measures were taken from subjects inserting their arms into a transparent Plexiglas® tube, a novel technique facilitating repeated measures of nonanesthetized apes in captivity. Measures from adult females (>12 years) showed that bonobos exceed chimpanzees in terms of forearm length and that sexual dimorphism in forearm length is pronounced in chimpanzees, but not in bonobos. Forearm length increased significantly with chronological age in bonobos. Validation tests revealed that the device generates useful data on morphometric dimensions. In most primates, sexual dimorphism in body size is male-biased and the differences in forearm length in chimpanzees follow this trend. Given that males of the two species did not differ in forearm length, the absence/presence of sexual dimorphism of this trait must be due to differences in somatic growth in females. Our novel method offers an alternative to obtain morphometric measures and facilitates longitudinal studies on somatic growth. Am J Phys Anthropol 161:37-43, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Figueroa, Debbie M; Bass, Hank W
2012-05-01
Integrated cytogenetic pachytene fluorescence in situ hybridization (FISH) maps were developed for chromosomes 1, 3, 4, 5, 6, and 8 of maize using restriction fragment length polymorphism marker-selected Sorghum propinquum bacterial artificial chromosomes (BACs) for 19 core bin markers and 4 additional genetic framework loci. Using transgenomic BAC FISH mapping on maize chromosome addition lines of oats, we found that the relative locus position along the pachytene chromosome did not change as a function of total arm length, indicative of uniform axial contraction along the fibers during mid-prophase for tested loci on chromosomes 4 and 5. Additionally, we cytogenetically FISH mapped six loci from chromosome 9 onto their duplicated syntenic regions on chromosomes 1 and 6, which have varying amounts of sequence divergence, using sorghum BACs homologous to the chromosome 9 loci. We found that successful FISH mapping was possible even when the chromosome 9 selective marker had no counterpart in the syntenic block. In total, these 29 FISH-mapped loci were used to create the most extensive pachytene FISH maps to date for these six maize chromosomes. The FISH-mapped loci were then merged into one composite karyotype for direct comparative analysis with the recombination nodule-predicted cytogenetic, genetic linkage, and genomic physical maps using the relative marker positions of the loci on all the maps. Marker colinearity was observed between all pair-wise map comparisons, although marker distribution patterns varied widely in some cases. As expected, we found that the recombination nodule-based predictions most closely resembled the cytogenetic map positions overall. Cytogenetic and linkage map comparisons agreed with previous studies showing a decrease in marker spacing in the peri-centromeric heterochromatin region on the genetic linkage maps. In fact, there was a general trend with most loci mapping closer towards the telomere on the linkage maps than on the cytogenetic maps, regardless of chromosome number or maize inbred line source, with just some of the telomeric loci exempted. Finally and somewhat surprisingly, we observed considerable variation between the relative arm positions of loci when comparing our cytogenetic FISH map to the B73 genomic physical maps, even where comparisons were to a B73-derived cytogenetic map. This variation is more evident between different chromosome arms, but less so within a given arm, ruling out any type of inbred-line dependent global features of linear deoxyribonucleic acid compared with the meiotic fiber organization. This study provides a means for analyzing the maize genome structure by producing new connections for integrating the cytogenetic, linkage, and physical maps of maize.
A simple integrated ratiometric wavelength monitor based on multimode interference structure
NASA Astrophysics Data System (ADS)
Hatta, Agus Muhamad; Farrell, Gerald; Wang, Qian
2008-09-01
Wavelength measurement or monitoring can be implemented using a ratiometric power measurement technique. A ratiometric wavelength monitor normally consists of a Y-branch splitter with two arms: an edge filter arm with a well defined spectral response and a reference arm or alternatively, two edge filters arms with opposite slope spectral responses. In this paper, a simple configuration for an integrated ratiometric wavelength monitor based on a single multimode interference structure is proposed. By optimizing the length of the MMI and the two output port positions, opposite spectral responses for the two output ports can be achieved. The designed structure demonstrates a spectral response suitable for wavelength measurement with potentially a 10 pm resolution over a 100 nm wavelength range.
NASA Astrophysics Data System (ADS)
Berlinsky, N.
2007-05-01
The better way or optimal variant means economic advisability of organization and using the way and the same time minimization of anthropogenic press. The first problem's factor is - all kinds' variants cross the area of the Danube Biosphere Reserve. The next factor is - all kinds of variants need dredging works in the sea shallow water so called bar's zone for marine entrance channel. As for natural factors there are also two. The first one is a long term delta evolution and the second is the process of water discharge redistribution. If the human influence to the first factor is still limited the second factor's influence can be unlimited - it is easy to do by jetty or dams construction. At present there are nine possible variants of the DWW: Variant 1. It is an artificial canal built as an ameliorative at 80-s between the Danube and Sasik liman. It provokes the water discharge redistribution up on 16.6% from the Danube run off (from the total Q=3000 m3/c for 54 km), hydrological regime in Ukrainian delta and ecological conditions will be sharply worsened. This project supposed a giant dredging works. Variant 2. The Project of engineer P.S. Chekhovich (1904). The length of the canal is 10 km. (The problems are: it is an artificial canal, needs the bridge, cross the wetlands area, redistribute water discharge from the Danube). Variant 3. Solomonov branch - Zhebryany bay modern Project by engineer V.P. Zizak (2000), The problems are: it is an artificial canal also, but with locks, needs the bridge, to cross the wetlands area, the water discharge redistribution from the Danube up on 2.27% (from the total Q=3000 m3/c for 54 km). The length of the canal is 9 km. Two last variants have orientation from Solomonov arm to Zhebriany bay. The other variants of DWW linked with Ochakovsky and Starostambulsky arms systems. Ochakosky system is dying off system from geological point of view. There are two arms which can be examined for DWW - Prorva arm and Potapovo arm. Besides, Ochakovska system needs dykes along both of shores but its construction may have strong influence on ecosystem. The second variant in this system is Potapovo DWW. So, all problems with dyke constructions are continuing besides this DWW passes through the one of the Strict Protection UNESCO zone in Biosphere Reserve, so call iadro. For fundamental reconstruction of Ochakovska system it is necessary to redistribute water discharge in the inner delta. It means to construct the dam in Starostambulsky system and redistribute water to Ochakovska system. In this case ecological situation in Starostambulsky system will be catastrophic. Hydrology regime modification influences the animal and plant kingdom. In the Starostambulsy mouth there is also the Strict Protection UNESCO zone in Biosphere Reserve. All kinds of alternative variants of DWW are dangerous for ecological condition of Chilia delta because considerable part of fresh water will be withdrawn from Ukrainian part of delta (upper 20 km) and it will provoke degradation of living condition for water plants and animals in the delta and Biosphere reserve including. The other Projects are directly linked with strong influence on the zones under strict protection (UNESCO) in the Danube Biosphere reserve. So, safest project is Bystryy DWW, because its conditions created by nature itself and don't need additional artificial constructions. Ukrainian DWW in Starostambulsky arm can be the reason of ecological and economic problems for Romanian side (silting of Sulina DWW).
No Telescoping Effect with Dual Tendon Vibration
Bellan, Valeria; Wallwork, Sarah B.; Stanton, Tasha R.; Reverberi, Carlo; Gallace, Alberto; Moseley, G. Lorimer
2016-01-01
The tendon vibration illusion has been extensively used to manipulate the perceived position of one’s own body part. However, findings from previous research do not seem conclusive sregarding the perceptual effect of the concurrent stimulation of both agonist and antagonist tendons over one joint. On the basis of recent data, it has been suggested that this paired stimulation generates an inconsistent signal about the limb position, which leads to a perceived shrinkage of the limb. However, this interesting effect has never been replicated. The aim of the present study was to clarify the effect of a simultaneous and equal vibration of the biceps and triceps tendons on the perceived location of the hand. Experiment 1 replicated and extended the previous findings. We compared a dual tendon stimulation condition with single tendon stimulation conditions and with a control condition (no vibration) on both ‘upward-downward’ and ‘towards-away from the elbow’ planes. Our results show a mislocalisation towards the elbow of the position of the vibrated arm during dual vibration, in line with previous results; however, this did not clarify whether the effect was due to arm representation contraction (i.e., a ‘telescoping’ effect). Therefore, in Experiment 2 we investigated explicitly and implicitly the perceived arm length during the same conditions. Our results clearly suggest that in all the vibration conditions there was a mislocalisation of the entire arm (including the elbow), but no evidence of a contraction of the perceived arm length. PMID:27305112
No Telescoping Effect with Dual Tendon Vibration.
Bellan, Valeria; Wallwork, Sarah B; Stanton, Tasha R; Reverberi, Carlo; Gallace, Alberto; Moseley, G Lorimer
2016-01-01
The tendon vibration illusion has been extensively used to manipulate the perceived position of one's own body part. However, findings from previous research do not seem conclusive sregarding the perceptual effect of the concurrent stimulation of both agonist and antagonist tendons over one joint. On the basis of recent data, it has been suggested that this paired stimulation generates an inconsistent signal about the limb position, which leads to a perceived shrinkage of the limb. However, this interesting effect has never been replicated. The aim of the present study was to clarify the effect of a simultaneous and equal vibration of the biceps and triceps tendons on the perceived location of the hand. Experiment 1 replicated and extended the previous findings. We compared a dual tendon stimulation condition with single tendon stimulation conditions and with a control condition (no vibration) on both 'upward-downward' and 'towards-away from the elbow' planes. Our results show a mislocalisation towards the elbow of the position of the vibrated arm during dual vibration, in line with previous results; however, this did not clarify whether the effect was due to arm representation contraction (i.e., a 'telescoping' effect). Therefore, in Experiment 2 we investigated explicitly and implicitly the perceived arm length during the same conditions. Our results clearly suggest that in all the vibration conditions there was a mislocalisation of the entire arm (including the elbow), but no evidence of a contraction of the perceived arm length.
NASA Technical Reports Server (NTRS)
Vijayakumar, M.; Tewari, S. N.; Lee, J. E.; Curreri, P. A.
1990-01-01
Single crystal specimens of nickel base superalloy PWA-1480 were directionally solidified on ground and during low gravity (20 sec) and high gravity (90 sec) parabolic maneuver of KC-135 aircraft. Thermal profiles were measured during solidification by two in-situ thermocouples positioned along the sample length. The samples were quenched during either high or low gravity cycles so as to freeze the structures of the mushy zone developing under different gravity levels. Microsegregation was measured by examining the solutal profiles on several transverse cross-sections across primary dendrites along their length in the quenched mushy zone. Effect of gravity level on secondary arm coarsening kinetics and microsegregation have been investigated. The results indicate that there is no appreciable difference in the microsegregation and coarsening kinetics behavior in the specimens grown under high or low gravity. This suggests that short duration changes in gravity/levels (0.02 to 1.7 g) do not influence convection in the interdendritic region. Examination of the role of natural convection, in the melt near the primary dendrite tips, on secondary arm spacings requires low gravity periods longer than presently available on KC-135. Secondary arm coarsening kinetics show a reasonable fit with the predictions from a simple analytical model proposed by Kirkwood for a binary alloy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sutton, Andrew; Shaddock, Daniel A.; Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California 91109
The Laser Interferometer Space Antenna (LISA) will be the first dedicated space based gravitational wave detector. LISA will consist of a triangular formation of spacecraft, forming an interferometer with 5x10{sup 6} km long arms. Annual length variations of the interferometer arms prevent exact laser frequency noise cancellation. Despite prestabilization to an optical cavity the expected frequency noise is many orders of magnitude larger than the required levels. Arm locking is a feedback control method that will further stabilize the laser frequency by referencing it to the 5x10{sup 6} km arms. Although the original arm locking scheme produced a substantial noisemore » reduction, the technique suffered from slowly decaying start-up transients and excess noise at harmonic frequencies of the inverse round-trip time. Dual arm locking, presented here, improves on the original scheme by combining information from two interferometer arms for feedback control. Compared to conventional arm locking, dual arm locking exhibits significantly reduced start-up transients, no noise amplification at frequencies within the LISA signal band, and more than 50 fold improvement in noise suppression at low frequencies. In this article we present a detailed analysis of the dual arm locking control system and present simulation results showing a noise reduction of 10 000 at a frequency of 10 mHz.« less
Cortical Spiking Network Interfaced with Virtual Musculoskeletal Arm and Robotic Arm.
Dura-Bernal, Salvador; Zhou, Xianlian; Neymotin, Samuel A; Przekwas, Andrzej; Francis, Joseph T; Lytton, William W
2015-01-01
Embedding computational models in the physical world is a critical step towards constraining their behavior and building practical applications. Here we aim to drive a realistic musculoskeletal arm model using a biomimetic cortical spiking model, and make a robot arm reproduce the same trajectories in real time. Our cortical model consisted of a 3-layered cortex, composed of several hundred spiking model-neurons, which display physiologically realistic dynamics. We interconnected the cortical model to a two-joint musculoskeletal model of a human arm, with realistic anatomical and biomechanical properties. The virtual arm received muscle excitations from the neuronal model, and fed back proprioceptive information, forming a closed-loop system. The cortical model was trained using spike timing-dependent reinforcement learning to drive the virtual arm in a 2D reaching task. Limb position was used to simultaneously control a robot arm using an improved network interface. Virtual arm muscle activations responded to motoneuron firing rates, with virtual arm muscles lengths encoded via population coding in the proprioceptive population. After training, the virtual arm performed reaching movements which were smoother and more realistic than those obtained using a simplistic arm model. This system provided access to both spiking network properties and to arm biophysical properties, including muscle forces. The use of a musculoskeletal virtual arm and the improved control system allowed the robot arm to perform movements which were smoother than those reported in our previous paper using a simplistic arm. This work provides a novel approach consisting of bidirectionally connecting a cortical model to a realistic virtual arm, and using the system output to drive a robotic arm in real time. Our techniques are applicable to the future development of brain neuroprosthetic control systems, and may enable enhanced brain-machine interfaces with the possibility for finer control of limb prosthetics.
Geramy, Allahyar; Hassanpour, Mehdi; Emadian Razavi, Elham sadat
2015-01-01
Objectives: This study sought to assess distal and lateral forces and moments of asymmetric headgears by variable outer bow lengths. Materials and Methods: Four 3D finite element method (FEM) models of a cervical headgear attached to the maxillary first molars were designed in SolidWorks 2010 software and transferred to ANSYS Workbench ver. 11 software. Models contained the first molars, their periodontal ligament (PDL), cancellous and cortical bones, a mesiodistal slice of the maxillae and the headgear. Models were the same except for the outer bow length in headgears. The headgear was symmetric in model 1. In models 2 to 4, the headgears were asymmetric in length with differences of 5mm, 10mm and 15mm, respectively. A 2.5 N force in horizontal plane was applied and the loading manner of each side of the outer bow was calculated trigonometrically using data from a volunteer. Results: The 15mm difference in outer bow length caused the greatest difference in lateral (=0.21 N) and distal (= 1.008 N) forces and also generated moments (5.044 N.mm). Conclusion: As the difference in outer bow length became greater, asymmetric effects increased. Greater distal force in the longer arm side was associated with greater lateral force towards the shorter arm side and more net yawing moment. Clinical Relevance: A difference range of 1mm to 15 mm of length in cervical headgear can be considered as a safe length of outer bow shortening in clinical use. PMID:26622275
Kalkman, Barbara M; Bar-On, Lynn; Cenni, Francesco; Maganaris, Constantinos N; Bass, Alfie; Holmes, Gill; Desloovere, Kaat; Barton, Gabor J; O'Brien, Thomas D
2017-05-03
When studying muscle and whole-body function in children with cerebral palsy (CP), knowledge about both internal and external moment arms is essential since they determine the mechanical advantage of a muscle over an external force. Here we asked if Achilles tendon moment arm (MA AT ) length is different in children with CP and age-matched typically developing (TD) children, and if MA AT can be predicted from anthropometric measurements. Sixteen children with CP (age: 10y 7m±3y, 7 hemiplegia, 12 diplegia, GMFCS level: I (11) and II (8)) and twenty TD children (age: 10y 6m±3y) participated in this case-control study. MA AT was calculated at 20° plantarflexion by differentiating calcaneus displacement with respect to ankle angle. Seven anthropometric variables were measured and related to MA AT . We found normalized MA AT to be 15% (∼7mm) smaller in children with CP compared to TD children (p=0.003). MA AT could be predicted by all anthropometric measurements with tibia length explaining 79% and 72% of variance in children with CP and TD children, respectively. Our findings have important implications for clinical decision making since MA AT influences the mechanical advantage about the ankle, which contributes to movement function and is manipulated surgically. Copyright © 2017 Elsevier Ltd. All rights reserved.
... of presbyopia when you start holding books and newspapers at arm's length to be able to read ... of Privacy Practices Notice of Nondiscrimination Manage Cookies Advertising Mayo Clinic is a not-for-profit organization ...
Tepe, Gunnar; Schneider, Peter; Brodmann, Marianne; Krishnan, Prakash; Micari, Antonio; Metzger, Christopher; Scheinert, Dierk; Zeller, Thomas; Cohen, David J.; Snead, David B.; Alexander, Beaux; Landini, Mario; Jaff, Michael R.
2015-01-01
Background— Drug-coated balloons (DCBs) have shown promise in improving the outcomes for patients with peripheral artery disease. We compared a paclitaxel-coated balloon with percutaneous transluminal angioplasty (PTA) for the treatment of symptomatic superficial femoral and popliteal artery disease. Methods and Results— The IN.PACT SFA Trial is a prospective, multicenter, single-blinded, randomized trial in which 331 patients with intermittent claudication or ischemic rest pain attributable to superficial femoral and popliteal peripheral artery disease were randomly assigned in a 2:1 ratio to treatment with DCB or PTA. The primary efficacy end point was primary patency, defined as freedom from restenosis or clinically driven target lesion revascularization at 12 months. Baseline characteristics were similar between the 2 groups. Mean lesion length and the percentage of total occlusions for the DCB and PTA arms were 8.94±4.89 and 8.81±5.12 cm (P=0.82) and 25.8% and 19.5% (P=0.22), respectively. DCB resulted in higher primary patency versus PTA (82.2% versus 52.4%; P<0.001). The rate of clinically driven target lesion revascularization was 2.4% in the DCB arm in comparison with 20.6% in the PTA arm (P<0.001). There was a low rate of vessel thrombosis in both arms (1.4% after DCB and 3.7% after PTA [P=0.10]). There were no device- or procedure-related deaths and no major amputations. Conclusions— In this prospective, multicenter, randomized trial, DCB was superior to PTA and had a favorable safety profile for the treatment of patients with symptomatic femoropopliteal peripheral artery disease. Clinical Trial Registration— URL: http://www.clinicaltrials.gov. Unique Identifiers: NCT01175850 and NCT01566461. PMID:25472980
Axillary nerve course and position in the fetal period
Uluer, Tuğba; Aktekin, Mustafa; Kurtoğlu, Zeliha; Buluklu, Semih; Karşıyaka, Dilan; Can, Erdem
2015-01-01
Objectives: To examine the fetal axillary nerve to reveal and compare its morphometric features within the second and third trimester. Methods: This study was conducted at the Anatomy Department, School of Medicine, Mersin University, Mersin, Turkey. Thirty-five fetal shoulders were studied to provide anatomic data and to describe its position with regard to certain landmarks around the shoulder. Results: The shortest distance between the axillary nerve and the glenoid labrum was found 2.27 mm and 2.89 mm in the second and third trimester fetuses, respectively. The shortest distances between the anterior and posterior acromial tips and the axillary nerve were also measured and were used with arm length measurements to define the anterior and posterior indexes. Conclusion: The indexes show that the distance between the axillary nerve and the anterior/posterior acromial tips are approximately one-fourth of the arm length in both the second and third trimester fetuses. The data presented in this study will be of use to surgeons, particularly to pediatric and orthopedic surgeons who will undertake surgical procedures in the axilla and arm in the newborn or early childhood. PMID:26492124
Iseki, Naoyuki; Sasaki, Akira; Toju, Hirokazu
2011-09-21
The geographical cline of the coevolving traits of weevil rostrum (mouthpart) length and camellia pericarp (fruit coat) thickness provides an opportunity to test the arms race theory of defense (pericarp thickness) and countermeasure (rostrum length) between antagonistically interacting species. By extending the previous model for the coevolution of quantitative traits to introduce nonlinear costs for exaggerated traits, the generation overlap, and density-dependent regulation in the host, we studied the evolutionarily stable (ES) pericarp thickness in the Japanese camellia (Camellia japonica) and the ES rostrum length in the camellia-weevil (Curculio camelliae). The joint monomorphic ES system has a robust outcome with nonlinear costs, and we analyzed how the traits of both species at evolutionary equilibrium depend on demographic parameters. If camellia demographic parameters vary latitudinally, data collected over the geographical scale of rostrum length and pericarp thickness should lie on an approximately linear curve with the slope less than that of the equiprobability line A/B of boring success, where A and B are coefficients for the logistic regression of boring success to pericarp thickness and rostrum length, respectively. This is a robust prediction as long as the cost of rostrum length is nonlinear (accelerating). As a result, boring success should be lower in populations with longer rostrum length, as reported in the weevil-camellia system (Toju, H., and Sota, T., 2006a. Imbalance of predator and prey armament: Geographic clines in phenotypic interface and natural selection. American Naturalist 167, 105-117). The nonlinearity (exponent) for the cost of rostrum length estimated from the geographical cline data for the weevil-camellia system was 2.2, suggesting nonlinearity between quadratic and cubic forms. Copyright © 2011 Elsevier Ltd. All rights reserved.
[Surgical Correction of Scoliosis: Does Intraoperative CT Navigation Prolong Operative Time?
Skála-Rosenbaum, J; Ježek, M; Džupa, V; Kadeřábek, R; Douša, P; Rusnák, R; Krbec, M
2016-01-01
PURPOSE OF THE STUDY The aim of the study was to compare the duration of corrective surgery for scoliosis in relation to the intra-operative use of either fluoroscopic or CT navigation. MATERIAL AND METHODS The indication for surgery was adolescent idiopathic scoliosis in younger patients and degenerative scoliosis in middleage or elderly patients. In a retrospective study, treatment outcomes in 43 consecutive patients operated on between April 2011 and April 2014 were compared. Only patients undergoing surgical correction of five or more spinal segments (fixation of six and more vertebrae) were included. RESULTS Transpedicular screw fixation of six to 13 vertebrae was performed under C-arm fluoroscopy guidance in 22 patients, and transpedicular screws were inserted in six to 14 vertebrae using the O-arm imaging system in 21 patients. A total of 246 screws were placed using the C-arm system and 340 screws were inserted using the O-arm system (p < 0.001). The procedures with use of the O-arm system were more complicated and required an average operative time longer by 48% (measured from the first skin incision to the completion of skin suture). However, the mean time needed for one screw placement (the sum of all surgical procedures with the use of a navigation technique divided by the number of screws placed using this technique) was the same in both techniques (19 min). DISCUSSION With good teamwork (surgeons, anaesthesiologists and a radiologist attending to the O-arm system), the time required to obtain one intra-operative CT scan is 3 to 5 minutes. The study showed that the mean time for placement of one screw was identical in both techniques although the average operative time was longer in surgery with O-arm navigation. The 19- minute interval was not the real placement time per screw. It was the sum of all operative times of surgical procedures (from first incision to suture completion including the whole approach within the range of planned stabilization) which used the same navigation technique divided by the number of all screws inserted during the procedures. The longer average operative time in procedures using O-arm navigation was not related to taking intra-operative O-arm scans. The authors consider surgery with an O-arm imaging system to be a safer procedure and use it currently in surgical correction of scoliosis. CONCLUSIONS The study focused on the length of surgery to correct scoliosis performed using either conventional fluoroscopy (C-arm) or intra-operative CT scanning (O-arm) showed that the mean placement time for one screw was identical in both imaging techniques when six or more vertebrae were stabilised. The use of intra-operative CT navigation did not make the surgery longer, and the higher number of inserted screws provides evidence that this technique is safer and allows us to achieve good stability of the correction procedure. Key words: virtual CT guidance, O-arm, scoliosis, transpedicular screw.
Lange, Jeffrey; Karellas, Andrew; Street, John; Eck, Jason C; Lapinsky, Anthony; Connolly, Patrick J; Dipaola, Christian P
2013-03-01
Observational. To estimate the radiation dose imparted to patients during typical thoracolumbar spinal surgical scenarios. Minimally invasive techniques continue to become more common in spine surgery. Computer-assisted navigation systems coupled with intraoperative cone-beam computed tomography (CT) represent one such method used to aid in instrumented spinal procedures. Some studies indicate that cone-beam CT technology delivers a relatively low dose of radiation to patients compared with other x-ray-based imaging modalities. The goal of this study was to estimate the radiation exposure to the patient imparted during typical posterior thoracolumbar instrumented spinal procedures, using intraoperative cone-beam CT and to place these values in the context of standard CT doses. Cone-beam CT scans were obtained using Medtronic O-arm (Medtronic, Minneapolis, MN). Thermoluminescence dosimeters were placed in a linear array on a foam-plastic thoracolumbar spine model centered above the radiation source for O-arm presets of lumbar scans for small or large patients. In-air dosimeter measurements were converted to skin surface measurements, using published conversion factors. Dose-length product was calculated from these values. Effective dose was estimated using published effective dose to dose-length product conversion factors. Calculated dosages for many full-length procedures using the small-patient setting fell within the range of published effective doses of abdominal CT scans (1-31 mSv). Calculated dosages for many full-length procedures using the large-patient setting fell within the range of published effective doses of abdominal CT scans when the number of scans did not exceed 3. We have demonstrated that single cone-beam CT scans and most full-length posterior instrumented spinal procedures using O-arm in standard mode would likely impart a radiation dose within the range of those imparted by a single standard CT scan of the abdomen. Radiation dose increases with patient size, and the radiation dose received by larger patients as a result of more than 3 O-arm scans in standard mode may exceed the dose received during standard CT of the abdomen. Understanding radiation imparted to patients by cone-beam CT is important for assessing risks and benefits of this technology, especially when spinal surgical procedures require multiple intraoperative scans.
Nutritional status of mentally retarded children in north-west Spain. I. Anthropometric indicators.
Sánchez-Lastres, J; Eirís-Puñal, J; Otero-Cepeda, J L; Pavón-Belinchón, P; Castro-Gago, M
2003-06-01
To evaluate the nutritional status of mentally retarded children in the region of Galicia in north-west Spain, on the basis of anthropometric variables. The following variables were determined in a sample of 128 mentally retarded children (81 M, 47 F): birthweight, bodyweight, height/length, head circumference, mid-arm circumference, mid-arm muscle circumference, triceps skinfold thickness, subscapular skinfold thickness, arm area, arm muscle area, arm fat area, arm lean-to-fat ratio, Shukla's nutrition index and Quetelet's body mass index (BMI). A preliminary statistical analysis indicated that most information content could be maintained considering only eight of these variables. A factor analysis of the resulting 8 x 128 (variables by subjects) data matrix was performed, identifying two factors (FA1 and FA2) that together explained 82% of total variance. Taking these factors as indicators of nutritional status, the data were analysed for possible effects of age, gender, socioeconomic and family environment, intelligence quotient (IQ), presence/absence of cerebral palsy, quality of diet, appetite and antiepileptic use. The analysis suggested that most subjects were in the normal nutrition range, but about 33% showed either borderline or definite malnutrition. Mean score on FA2 showed a significant negative correlation with age. Children with cerebral palsy had lower mean scores on both factors, and scores on both factors varied with IQ. Children with definite malnutrition had a significantly lower IQ than those in the normal nutrition range. Mean score on both factors varied with appetite and quality of diet. The mean FAI score of children from inland-rural areas was significantly lower than that of children from coastal or urban areas. Mean FA1 score increased with increasing age of the parents. The prevalence of obesity was 13% when obesity was defined on the basis of Shukla's nutrition index, and 19% when defined on the basis of FA1 score. Malnutrition as revealed by anthropometric variables occurs with a high prevalence among mentally retarded children. The prevalence increases with age, increasing IQ deficit and cerebral palsy.
Kobayashi, Kazuyoshi; Ando, Kei; Ito, Kenyu; Tsushima, Mikito; Morozumi, Masayoshi; Tanaka, Satoshi; Machino, Masaaki; Ota, Kyotaro; Ishiguro, Naoki; Imagama, Shiro
2018-05-01
The O-arm ® navigation system allows intraoperative CT imaging that can facilitate highly accurate instrumentation surgery, but radiation exposure is higher than with X-ray radiography. This is a particular concern in pediatric surgery. The purpose of this study is to examine intraoperative radiation exposure in pediatric spinal scoliosis surgery using O-arm. The subjects were 38 consecutive patients (mean age 12.9 years, range 10-17) with scoliosis who underwent spinal surgery with posterior instrumentation using O-arm. The mean number of fused vertebral levels was 11.0 (6-15). O-arm was performed before and after screw insertion, using an original protocol for the cervical, thoracic, and lumbar spine doses. The average scanning range was 6.9 (5-9) intervertebral levels per scan, with 2-7 scans per patient (mean 4.0 scans). Using O-arm, the dose per scan was 92.5 (44-130) mGy, and the mean total dose was 401 (170-826) mGy. This dose was 80.2% of the mean preoperative CT dose of 460 (231-736) mGy (P = 0.11). The total exposure dose and number of scans using intraoperative O-arm correlated strongly and significantly with the number of fused levels; however, there was no correlation with the patient's height. As the fused range became wider, several scans were required for O-arm, and the total radiation exposure became roughly the same as that in preoperative CT. Use of O-arm in our original protocol can contribute to reduction in radiation exposure.
NASA Astrophysics Data System (ADS)
Ge, Hui
This Ph. D. thesis presents our study on the ultrafiltration of polymers with different configurations and conformations; namly, theoretically, the passing of polymer chains through a nanopore under an elongational flow filed has been studied for years, but experimental studies are rare because of two following reasons: (1) lacks a precise method to investigate how individual single polymer chain pass through a nanopore; (2) it is difficult, if not impossible, to obtain a set of polymer samples with a narrow molar mass distribution and a uniform structures; except for linear chains. The central question in this study is to find the critical (minimum) flow rate (qc) for each kind of chains, at which the chains can pass through a given nanopore. A comparison of the measured and calculated qc leads to a better understanding how different chains are deformed, stretched and pulled through a nanopore. We have developed a novel method of combinating static and dynamic laser light scattering (LLS) to precisely measure the relative retention concentration ((C0 - C)/C0). Chapter 1 briefly introduces the theoretical background of how applications and lists some of resent research progresses in this area. Polymer with various configurations and conformations pass through nanopores; including polymer linear chains, stars polymer, branched polymers, polymer micelles are introduced. Among them, the de Gennes and Brochard-Wyart's predictions of polymer linear and star chains passing through nanopores are emphasized, in which they predicted that qc of linear chain is qc ≃ kBT/(3pieta), where kB, T and eta are the Boltzmann constant, the absolutely temperature, and the viscosity of solvent, respectively, independent of both the chain length and the pore size; and for star chains passing through nanopores, there exist a optimal entering arm numbers, namely, the star chains passing through nanopores. Chapter 2 details basic theory of static and dynamic laser light scattering (LLS), including its instrumentation and our ultrafiltration setup. Chapter 3 briefly introduces the sample preparation, including the history and mechanism of anionic living polymerization, as well as how we used a novel home-made set-up to prepare linear polystyrene with different chain lengths and star polystyrene with various arm numbers and lengths. Chapter 4 summarizes our measured critical flow rates (qc) of linear polymer chains with different lengths for nanopores with different sizes, since the flow rate is directly related to the hydrodynamic force, we have developed a sensitive method (down to tens fN) to directly assess how much the hydrodynamic force (Fh) is required to overcome the weak entropy elasticity and stretch individual coiled chains in solution. Our method is completely different from the using existing optical tweezers or AFM, because they measure the relatively stronger enthalpy elasticity. Our results confirm that qc is indeed independent of the chain length, but decreases as the pore size increases. The value of qc is ˜10--200 times smaller than kBT/(3pieta). Such a discrepancy has been attributed to the rough assumption made by de Gennes and his coworkers; namely, each chain segment "blob" confined inside the pore is not a hard sphere so that the effective length along the flow direction is much longer than the pore diameter. Finally, using the solution temperature, we varied the chain conformation, our result shows that q c has a minimum which is near, but not exactly located at the theta temperature, might leading to a better way to determine the true ideal state of a polymer solution, at which all viral coefficients, not only the second vanish. Chapter 5 uses polymer solutions made of different mixtures of linear and star chains, we have demonstrated that flushing these solution mixtures through a nanopore with a properly chosen flow rate can effectively and cleanly separate linear and star chains no matter whether linear chains are larger or smaller than star chains. Chapter 6 further investigates how star-like polystyrene pass through a given nanopore under the flow field. Star polystyrene chains with different arm lengths (LA) and numbers (f) passing through a nanopore (20 nm) under an elongational flow field was investigated in terms of the flow-rate dependent relative retention ((C0 - C)/C0), where C 0 and C are the polymer concentrations before and after the ultrafiltration. Our results reveal that for a given arm length (LA), the critical flow rate (qc,star), below which star chains are blocked, dramatically increases with the total arm numbers (f); but for a given f, is nearly independent on LA, contradictory to the previous prediction made by de Gennes and Brochard-Wyart. We have revised their theory in the region fin < fout and also accounted for the effective length of each blob, where fin and fout are the numbers of arms inside and outside the pore, respectively. In the revision, we show that qc,star is indeed independent of LA but related to f and f in in two different ways, depending on whether fin ≤ f/2 or ≥ f/2. A comparison of our experimental and calculated results reveals that most of star chains pass through the nanopores with fin ˜ f/2. Further study of the temperature dependent (C0 - C)/C 0 of polystyrene in cyclohexane reveals that there exists a minimum of qc,star at ˜38 °C, close to its theta temperature (-34.5 °C).
Grijalva-Eternod, Carlos S; Wells, Jonathan C K; Girma, Tsinuel; Kæstel, Pernille; Admassu, Bitiya; Friis, Henrik; Andersen, Gregers S
2015-09-01
A midupper arm circumference (MUAC) <115 mm and weight-for-height z score (WHZ) or weight-for-length z score (WLZ) less than -3, all of which are recommended to identify severe wasting in children, often identify different children. The reasons behind this poor agreement are not well understood. We investigated the association between these 2 anthropometric indexes and body composition to help understand why they identify different children as wasted. We analyzed weight, length, MUAC, fat-mass (FM), and fat-free mass (FFM) data from 2470 measurements from 595 healthy Ethiopian infants obtained at birth and at 1.5, 2.5, 3.5, 4.5, and 6 mo of age. We derived WLZs by using 2006 WHO growth standards. We derived length-adjusted FM and FFM values as unexplained residuals after regressing each FM and FFM against length. We used a correlation analysis to assess associations between length, FFM, and FM (adjusted and nonadjusted for length) and the MUAC and WLZ and a multivariable regression analysis to assess the independent variability of length and length-adjusted FM and FFM with either the MUAC or the WLZ as the outcome. At all ages, length showed consistently strong positive correlations with the MUAC but not with the WLZ. Adjustment for length reduced observed correlation coefficients of FM and FFM with the MUAC but increased those for the WLZ. At all ages, both length-adjusted FM and FFM showed an independent association with the WLZ and MUAC with higher regression coefficients for the WLZ. Conversely, length showed greater regression coefficients for the MUAC. At all ages, the MUAC was shown to be more influenced than was the WLZ by the FM variability relative to the FFM variability. The MUAC and WLZ have different associations with body composition, and length influences these associations differently. Our results suggest that the WLZ is a good marker of tissue masses independent of length. The MUAC acts more as a composite index of poor growth indexing jointly tissue masses and length. This trial was registered at www.controlled-trials.com as ISRCTN46718296. © 2015 American Society for Nutrition.
Sala, Alessandra; Rossi, Emanuela; Antillon, Federico; Molina, Ana Lucia; de Maselli, Tania; Bonilla, Miguel; Hernandez, Angelica; Ortiz, Roberta; Pacheco, Carlos; Nieves, Rosa; Navarrete, Marta; Barrantes, Max; Pencharz, Paul; Valsecchi, Maria Grazia; Barr, Ronald
2012-01-01
The prevalence of malnutrition in children may exceed 50% in countries with limited resources. The aims of this study were to assess nutritional status at diagnosis in children and adolescents with cancer, and to correlate it with clinical outcomes in the Spanish speaking countries of Central America that formed the AHOPCA (Asociacion de Hemato-Oncologia Pediatrica de Centro America) consortium. Patients aged 1-18 years, diagnosed with cancer between 1st October 2004 and 30th September 2007, were eligible for study. Weight (kg) and height or length (m), mid upper arm circumference--MUAC and triceps skin fold thickness--TSFT were measured and their Z-scores or percentiles were calculated. Three categories of nutritional status were defined according to these parameters. A total of 2954 new patients were enrolled; 1787 had all anthropometric measurements performed and 1513 also had measurements of serum albumin. By arm anthropometry 322/1787 patients (18%) had moderate nutritional depletion and 813/1787 patients (45%) were severely depleted. Adding serum albumin, the proportion classified as severely depleted rose to 59%. Malnourished children more often abandoned therapy and their event free survival was inferior to that of other children. Arm anthropometry in children with cancer is a sensitive measure of nutritional status. Since malnutrition at diagnosis was related to important clinical outcomes, an opportunity exists to devise simple, cost-effective nutritional interventions in such children that may enhance their prospects for survival. Copyright © 2011 Elsevier Ltd. All rights reserved.
Stump sensibility in children with upper limb reduction deficiency.
Reinkingh, Marianne; Reinders-Messelink, Heleen A; Dijkstra, Pieter U; Maathuis, Karel G B; van der Sluis, Corry K
2014-01-01
To compare stump sensibility in children with upper limb reduction deficiency with sensibility of the unaffected arm and hand. In addition, to evaluate the associations between stump sensibility, stump length and activity level. Cross-sectional study. Children and young adults aged 6-25 years with upper limb reduction deficiency. Threshold of touch was measured with Semmes-Weinstein monofilaments, stereognosis was measured with the Shape-Texture Identification test and kinaesthesia and activity level was measured with the Child Amputee Prosthetics Project - Functional Status Inventory and the Prosthetic Upper Extremity Functional Index. A total of 31 children with upper limb reduction deficiency (mean age 15 years, 3 prosthesis wearers) were investigated. The threshold of touch of the stump circumference was lower (indicating higher sensibility) than of the unaffected arm (p = 0.006), hand (p = 0.004) and stump end-point (p = < 0.001). Long stumps had higher threshold of touch (indicating lower sensibility) than short stumps (p = 0.046). Twenty-nine children recognized 1 or more shapes or textures with the stump. Kinaesthesia in the affected and unaffected sides was comparable. Sensibility was not correlated with activity level. Threshold of touch, stereognosis and kinaesthesia of the affected sides were excellent. Threshold of touch of the stump circumference was lower (indicating higher sensibility) than of the unaffected arm and hand. High stump sensibility may clarify good functioning in the children without prostheses and contribute to prosthesis rejection.
Karp, C.A.; Mueller, G.
2002-01-01
Seventeen subadult, hatchery-reared razorback suckers (Xyrauchen texanus; (x̄ = 456 mm total length) were implanted with sonic transmitters and tracked for 23 months in the lower 89.6 km of the San Juan River (San Juan arm of Lake Powell, Utah). Fish were released at 2 sites, and 9 made extensive up-and downstream movements (x = 47.8 km; contact was lost with 4, and 4 others presumably died or lost their transmitters). The San Juan arm is primarily inundated canyon; however, most fish contacts occurred in shallow coves and shoreline with thick stands of flooded salt cedar in the upper inflow area. Eight fish frequented the Piute Farms river/lake mixing zone, and at least 4 moved upstream into the San Juan River. Seven fish were found in 2 aggregations in spring (3 fish in Neskahi Bay in 1996 and 4 fish just downstream of Piute Farms in 1997), and these may have been associated with spawning activity. Continued presence of razorback suckers in the Piute Farms area and lower San Juan River suggests the San Juan inflow to Lake Powell could be used as an alternate stocking site for reintroduction efforts.
Yamamoto, Takumi; Yamamoto, Nana; Yoshimatsu, Hidehiko
2017-10-01
Volume measurement is a common evaluation for upper extremity lymphedema. However, volume comparison between different patients with different body types may be inappropriate, and it is difficult to evaluate localized limb volume change using arm volume. Localized arm volumes (Vk, k = 1-5) and localized arm volume indices (LAVIk) at 5 points (1, upper arm; 2, elbow; 3, forearm; 4, wrist; 5, hand) of 106 arms of 53 examinees with no arm edema were calculated based on physical measurements (arm circumferences and lengths and body mass index [BMI]). Interrater and intrarater reliabilities of LAVIk were assessed, and Vk and LAVIk were compared between lower BMI (BMI, <22 kg/m) group and higher BMI (BMI, ≥22 kg/m) group. Interrater and intrarater reliabilities of LAVIk were all high (all, r > 0.98). Between lower and higher BMI groups, significant differences were observed in all Vk (V1 [P = 6.8 × 10], V2 [P = 3.1 × 10], V3 [P = 1.1 × 10], V4 [P = 8.3 × 10], and V5 [P = 3.0 × 10]). Regarding localized arm volume index (LAVI) between groups, significant differences were seen in LAVI1 (P = 9.7 × 10) and LAVI5 (P = 1.2 × 10); there was no significant difference in LAVI2 (P = 0.60), LAVI3 (P = 0.61), or LAVI4 (P = 0.22). Localized arm volume index is a convenient and highly reproducible method for evaluation of localized arm volume change, which is less affected by body physique compared with arm volumetry.
Hundza, S R; de Ruiter, Geoff C; Klimstra, M; Zehr, E Paul
2012-12-01
Suppression of soleus H-reflex amplitude in stationary legs is seen during rhythmic arm cycling. We examined the influence of various arm-cycling parameters on this interlimb reflex modulation to determine the origin of the effect. We previously showed the suppression to be graded with the frequency of arm cycling but not largely influenced by changes in peripheral input associated with crank length. Here, we more explicitly explored the contribution of afferent feedback related to arm movement on the soleus H-reflex suppression. We explored the influence of load and rate of muscle stretch by manipulating crank-load and arm-muscle vibration during arm cycling. Furthermore, internally driven ("Active") and externally driven ("Passive") arm cycling was compared. Soleus H-reflexes were evoked with tibial nerve stimulation during stationary control and rhythmic arm-cycling conditions, including: 1) six different loads; 2) with and without vibration to arm muscles; and 3) Active and Passive conditions. No significant differences were seen in the level of suppression between the different crank loads or between conditions with and without arm-muscle vibration. Furthermore, in contrast to the clear effect seen during active cycling, passive arm cycling did not significantly suppress the soleus H-reflex amplitude. Current results, in conjunction with previous findings, suggest that the afferent feedback examined in these studies is not the primary source responsible for soleus H-reflex suppression. Instead, it appears that central motor commands (supraspinal or spinal in origin) associated with frequency of arm cycling are relatively more dominant sources.
NASA Astrophysics Data System (ADS)
Dianov, Evgenii M.; Kuznetsov, A. V.; Makarenko, A. Yu; Okhotnikov, O. G.; Prokhorov, A. M.; Shcherbakov, E. A.
1990-12-01
Single-mode fiber waveguides were used in constructing a Michelson interferometer with a 50-km difference between its arm lengths. An analysis was made of its resolving power as a function of the parameters of the optical part and of the characteristics of the electronic apparatus used in the system. The width of a spectral emission line of a semiconductor laser with a distributed Rayleigh fiber resonator was determined.
Elizabeth, Nabiwemba L; Christopher, Orach Garimoi; Patrick, Kolsteren
2013-04-12
Achieving Millennium Development Goal 4 is dependent on significantly reducing neonatal mortality. Low birth weight is an underlying factor in most neonatal deaths. In developing countries the missed opportunity for providing life saving care is mainly a result of failure to identify low birth weight newborns. This study aimed at identifying a reliable anthropometric measurement for screening low birth weight and determining an operational cut-off point in the Uganda setting. This simple measurement is required because of lack of weighing scales in the community, and sometimes in the health facilities. This was a hospital-based cross-sectional study. Two midwives weighed 706 newborns and measured their foot length, head, chest, thigh and mid-upper arm circumferences within 24 hours after birth.Data was analysed using STATA version 10.0. Correlation with birth weight using Pearson's correlation coefficient and Receiver Operating Characteristics curve analysis were done to determine the measure that best predicts birth weight. Sensitivity and specificity were calculated for a range of measures to obtain operational cut-off points; and Likelihood Ratios and Diagnostic Odds Ratio were determined for each cut-off point. Birth weights ranged from 1370-5350 grams with a mean of 3050 grams (SD 0.53) and 85 (12%) babies weighed less than 2500 grams. All anthropometric measurements had a positive correlation with birth weight, with foot length showing the strongest (r = 0.76) and thigh circumference the weakest (r = 0.62) correlations. Foot length had the highest predictive value for low birth weight (AUC = 0.97) followed by mid-upper arm circumference (AUC = 0.94). Foot length and chest circumference had the highest sensitivity (94%) and specificity (90%) respectively for screening low birth weight babies at the selected cut-off points. Chest circumference had a significantly higher positive likelihood ratio (8.7) than any other measure, and foot length had the lowest negative likelihood ratio. Chest circumference and foot length had diagnostic odds ratios of 97% and 77% respectively. Foot length was easier to measure and it involved minimal exposure of the baby to cold. A cut-off of foot length 7.9 cm had sensitivity of 94% and specificity of 83% for predicting low birth weight. This study suggests foot length as the most appropriate predictor for low birth weight in comparison to chest, head, mid-upper arm and thigh circumference in the Uganda setting. Use of low cost and easy to use tools to identify low birth weight babies by village health teams could support community efforts to save newborns.
Wagner-Johnston, Nina D; Sloan, Jeff A; Liu, Heshan; Kearns, Ann E; Hines, Stephanie L; Puttabasavaiah, Suneetha; Dakhil, Shaker R; Lafky, Jacqueline M; Perez, Edith A; Loprinzi, Charles L
2015-08-01
Postmenopausal women with breast cancer receiving aromatase inhibitors are at an increased risk of bone loss. The current study was undertaken to determine whether upfront versus delayed treatment with zoledronic acid (ZA) impacted bone loss. This report described the 5-year follow-up results. A total of 551 postmenopausal women with breast cancer who completed tamoxifen treatment and were undergoing daily letrozole treatment were randomized to either upfront (274 patients) or delayed (277 patients) ZA at a dose of 4 mg intravenously every 6 months. In the patients on the delayed treatment arm, ZA was initiated for a postbaseline bone mineral density T-score of <-2.0 or fracture. The incidence of a 5% decrease in the total lumbar spine bone mineral density at 5 years was 10.2% in the upfront treatment arm versus 41.2% in the delayed treatment arm (P<.0001). A total of 41 patients in the delayed treatment arm were eventually started on ZA. With the exception of increased NCI Common Toxicity Criteria (CTC) grade 1/2 elevated creatinine and fever in the patients treated on the upfront arm and cerebrovascular ischemia among those in the delayed treatment arm, there were no significant differences observed between arms with respect to the most common adverse events of arthralgia and back pain. Osteoporosis occurred less frequently in the upfront treatment arm (2 vs 8 cumulative cases), although this difference was not found to be statistically significant. Bone fractures occurred in 24 patients in the upfront treatment arm versus 25 patients in the delayed treatment arm. Immediate treatment with ZA prevented bone loss compared with delayed treatment in postmenopausal women receiving letrozole and these differences were maintained at 5 years. The incidence of osteoporosis or fractures was not found to be significantly different between treatment arms. © 2015 American Cancer Society.
Personnel occupied woven envelope robot
NASA Technical Reports Server (NTRS)
Wessling, Francis; Teoh, William; Ziemke, M. Carl
1988-01-01
The Personnel Occupied Woven Envelope Robot (POWER) provides an alternative to extravehicular activity (EVA) of space suited astronauts and/or use of long slender manipulator arms such as are used in the Shuttle Remote Manipulator System. POWER provides the capability for a shirt sleeved astronaut to perform such work by entering a control pod through air locks at both ends of an inflated flexible bellows (access tunnel). The exoskeleton of the tunnel is a series of six degrees of freedom (Six-DOF) articulated links compressible to 1/6 of their fully extended length. The operator can maneuver the control pod to almost any location within about 50 m of the base attachment to the space station. POWER can be envisioned as a series of hollow Six-DOF manipulator segments or arms wherein each arm grasps the shoulder of the next arm. Inside the hollow arms ia a bellow-type access tunnel. The control pod is the fist of the series of linked hollow arms. The fingers of the fist are conventional manipulator arms under direct visual control of the nearby operator in the pod. The applications and progress to date of the POWER system is given.
The Mars Surveyor '01 Rover and Robotic Arm
NASA Technical Reports Server (NTRS)
Bonitz, Robert G.; Nguyen, Tam T.; Kim, Won S.
1999-01-01
The Mars Surveyor 2001 Lander will carry with it both a Robotic Arm and Rover to support various science and technology experiments. The Marie Curie Rover, the twin sister to Sojourner Truth, is expected to explore the surface of Mars in early 2002. Scientific investigations to determine the elemental composition of surface rocks and soil using the Alpha Proton X-Ray Spectrometer (APXS) will be conducted along with several technology experiments including the Mars Experiment on Electrostatic Charging (MEEC) and the Wheel Abrasion Experiment (WAE). The Rover will follow uplinked operational sequences each day, but will be capable of autonomous reactions to the unpredictable features of the Martian environment. The Mars Surveyor 2001 Robotic Arm will perform rover deployment, and support various positioning, digging, and sample acquiring functions for MECA (Mars Environmental Compatibility Assessment) and Mossbauer Spectrometer experiments. The Robotic Arm will also collect its own sensor data for engineering data analysis. The Robotic Arm Camera (RAC) mounted on the forearm of the Robotic Arm will capture various images with a wide range of focal length adjustment during scientific experiments and rover deployment
Tayyib, Nahla; Coyer, Fiona; Lewis, Peter A
2015-05-01
This study tested the effectiveness of a pressure ulcer (PU) prevention bundle in reducing the incidence of PUs in critically ill patients in two Saudi intensive care units (ICUs). A two-arm cluster randomized experimental control trial. Participants in the intervention group received the PU prevention bundle, while the control group received standard skin care as per the local ICU policies. Data collected included demographic variables (age, diagnosis, comorbidities, admission trajectory, length of stay) and clinical variables (Braden Scale score, severity of organ function score, mechanical ventilation, PU presence, and staging). All patients were followed every two days from admission through to discharge, death, or up to a maximum of 28 days. Data were analyzed with descriptive correlation statistics, Kaplan-Meier survival analysis, and Poisson regression. The total number of participants recruited was 140: 70 control participants (with a total of 728 days of observation) and 70 intervention participants (784 days of observation). PU cumulative incidence was significantly lower in the intervention group (7.14%) compared to the control group (32.86%). Poisson regression revealed the likelihood of PU development was 70% lower in the intervention group. The intervention group had significantly less Stage I (p = .002) and Stage II PU development (p = .026). Significant improvements were observed in PU-related outcomes with the implementation of the PU prevention bundle in the ICU; PU incidence, severity, and total number of PUs per patient were reduced. Utilizing a bundle approach and standardized nursing language through skin assessment and translation of the knowledge to practice has the potential to impact positively on the quality of care and patient outcome. © 2015 Sigma Theta Tau International.
Carter, M; Zhu, F; Kotanko, P; Kuhlmann, M; Ramirez, L; Heymsfield, S B; Handelman, G; Levin, N W
2009-01-01
This study used multi-frequency bioimpedance spectroscopy (BIS) of the arm and whole body to estimate muscle mass (MM) and subcutaneous adipose tissue (SAT) in 31 hemodialysis (HD) patients comparing these results with magnetic resonance imaging (MRI) and body potassium ((40)K) as gold standards. Total body and arm MM (MM(MRI)) and SAT (SAT(MRI)) were measured by MRI. All measurements were made before dialysis treatment. Regression models with the arm (aBIS) and whole body (wBIS) resistances were established. Correlations between gold standards and the BIS model were high for the arm SAT (r(2) = 0.93, standard error of estimate (SEE) = 3.6 kg), and whole body SAT (r(2) = 0.92, SEE = 3.5 kg), and for arm MM (r(2) = 0.84, SEE = 2.28 kg) and whole body MM (r(2) = 0.86, SEE = 2.28 kg). Total body MM and SAT can be accurately predicted by arm BIS models with advantages of convenience and portability, and it should be useful to assess nutritional status in HD patients. Copyright (c) 2009 S. Karger AG, Basel.
Differentiated norepinephrine spillover in human skeletal muscle.
Karlsson, A K; Elam, M; Lönnroth, P; Sullivan, L; Friberg, P
1997-07-01
Most neurophysiological studies have shown similar sympathetic outflow to arm and leg. However, some direct microneurographic recordings indicate differentiated sympathetic outflow to limbs both at rest and during mental stress. Hence, differentiated levels of norepinephrine (NE) spillover could prevail. By steady-state infusion of [3H]NE and body composition determination by dual-energy X-ray absorptiometry-scan, we simultaneously assessed arm and leg NE spillover related to 100 g tissue and total limb weight. NE spillover was lower in leg than arm (0.26 vs. 1.51 pmol.min-1.100 g-1, P < 0.05), and the difference remained when expressed as a function of total limb weight (66 vs. 137 pmol/min, P < 0.05). Fractional extraction of [3H]NE was similar in arm and leg. Neuronal uptake blockade by desipramine was more effective in leg than arm; fractional extraction in leg decreased by 32% (P < 0.05) but was unaltered in arm. Thus a lower NE spillover was observed from leg than arm, possibly reflecting a lower sympathetic outflow and a more neuronally dependent reuptake.
Walker, David R; Kinney, Allison L; Wright, Thomas W; Banks, Scott A
2016-06-01
Reverse total shoulder arthroplasty commonly treats cuff-deficient or osteoarthritic shoulders not amenable to rotator cuff repair. This study investigates deltoid moment arm sensitivity to variations in the joint center and humeral offset of 3 representative reverse total shoulder arthroplasty subjects. We hypothesized that a superior joint implant placement may exist, indicated by muscle moment arms, compared with the current actual surgical implant configuration. Moment arms for the anterior, lateral, and posterior aspects of the deltoid muscle were determined for 1521 perturbations of the humeral offset location away from the surgical placement in a subject-specific musculoskeletal model with motion defined by subject-specific in vivo abduction kinematics. The humeral offset was varied from its surgical position ±4 mm in the anterior/posterior direction, ±12 mm in the medial/lateral direction, and -10 to 14 mm in the superior/inferior direction. The anterior deltoid moment arm varied in humeral offset and center of rotation up to 20 mm, primarily in the medial/lateral and superior/inferior directions. The lateral deltoid moment arm varied in humeral offset up to 20 mm, primarily in the medial/lateral and anterior/posterior directions. The posterior deltoid moment arm varied up to 15 mm, primarily in early abduction, and was most sensitive to humeral offset changes in the superior/inferior direction. High variations in muscle moment arms were found for all 3 deltoid components, presenting an opportunity to dramatically change the deltoid moment arms through surgical placement of the reverse shoulder components and by varying the overall offset of the humerus. Basic Science Study; Computer Modeling. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Dobaj, K.
2016-09-01
The work deals with the simulation analysis of the half car vehicle model parameters on the suspension testing results. The Matlab simulation software was used. The considered model parameters are involved with the shock absorber damping coefficient, the tire radial stiffness, the car width and the rocker arm length. The consistent vibrations of both test plates were considered. Both wheels of the car were subjected to identical vibration, with frequency changed similar to the EUSAMA Plus principle. The shock absorber damping coefficient (for several values of the car width and rocker arm length) was changed on one and both sides of the vehicle. The obtained results are essential for the new suspension testing algorithm (basing on the EUSAMA Plus principle), which will be the aim of the further author's work.
Seeing believes: Watching entangled sculpted branched DNA in real time
NASA Astrophysics Data System (ADS)
Jee, Ah-Young; Guan, Juan; Chen, Kejia; Granick, Steve
2015-03-01
The importance of branching in polymer physics is universally accepted but the details are disputed. We have sculpted DNA to various degrees of branching and used single-molecule tracking to image its diffusion in real time when entangled. By ligating three identical or varying length DNA segments, we construct symmetric and asymmetric ?Y? branches from elements of lambda-DNA with 16 um contour length, allowing for single-molecule visualization of equilibrium dynamics. Using home-written software, a full statistical distribution based on at least hundreds of trajectories is quantified with focus on discriminating arm-retraction from branch point motion. Some part of our observations is consistent with the anticipated ?relaxation through arm retraction? mechanism but other observations do not appear to be anticipated theoretically. Currently working as a researcher in Institute for Basic Science.
Kälin, Pascal S; Crawford, Rebecca J; Marcon, Magda; Manoliu, Andrei; Bouaicha, Samy; Fischer, Michael A; Ulbrich, Erika J
2018-04-23
We aimed to provide mean values for fat-fraction and volume for full-length bilateral rotator cuff and deltoid muscles in asymptomatic adults selected on the basis of their good musculoskeletal and systemic health, and to understand the influence of gender, age, and arm dominance. Seventy-six volunteers aged 20 to 60 years who were screened for normal BMI and high general health were included in the study. MRI was performed at 3 Tesla using three-point DIXON sequences. Volume and fat-signal fraction of the rotator cuff muscles and the deltoid muscle were determined with semi-automated segmentation of entire muscle lengths. Differences according to age, gender, and handedness per muscle were evaluated. Fat-signal fractions were comparable between genders (mean ± 2 SD, 95% CI, women 7.0 ± 3.0; 6.8-7.2%, men 6.8 ± 2.7; 6.7-7.0%) but did not show convincing changes with age. Higher shoulder muscle volume and lower fat-signal fraction in the dominant arm were shown for teres minor and deltoid (p < 0.01) with similar trends shown for the other rotator cuff muscles. Bilateral fat-signal fractions and volumes based on entire length shoulder muscles in asymptomatic 20-60 year old adults may provide reference for clinicians. Differences shown according to arm dominance should be considered and may rationalize the need for bilateral imaging in determining appropriate management.
Fatigue Magnification Factors of Arc-Soft-Toe Bracket Joints
NASA Astrophysics Data System (ADS)
Fu, Qiang; Li, Huajun; Wang, Hongqing; Wang, Shuqing; Li, Dejiang; Li, Qun; Fang, Hui
2018-06-01
Arc-soft-toe bracket (ASTB), as a joint structure in the marine structure, is the hot spot with significant stress concentration, therefore, fatigue behavior of ASTBs is an important point of concern in their design. Since macroscopic geometric factors obviously influence the stress flaws in joints, the shapes and sizes of ASTBs should represent the stress distribution around cracks in the hot spots. In this paper, we introduce a geometric magnification factor for reflecting the macroscopic geometric effects of ASTB crack features and construct a 3D finite element model to simulate the distribution of stress intensity factor (SIF) at the crack endings. Sensitivity analyses with respect to the geometric ratio H t / L b , R/ L b , L t / L b are performed, and the relations between the geometric factor and these parameters are presented. A set of parametric equations with respect to the geometric magnification factor is obtained using a curve fitting technique. A nonlinear relationship exists between the SIF and the ratio of ASTB arm to toe length. When the ratio of ASTB arm to toe length reaches a marginal value, the SIF of crack at the ASTB toe is not influenced by ASTB geometric parameters. In addition, the arc shape of the ASTB slope edge can transform the stress flowing path, which significantly affects the SIF at the ASTB toe. A proper method to reduce stress concentration is setting a slope edge arc size equal to the ASTB arm length.
Nath, Rahul K; Somasundaram, Chandra
2016-01-01
Assessment of surgical outcomes of biceps tendon lengthening (BTL) surgery in obstetric brachial plexus injury (OBPI) patients with elbow flexion contractures, who had unsuccessful serial casting. Serial casting and splinting have been shown to be effective in correcting elbow flexion contractures in OBPI. However, the possibilities of radial head dislocations and other complications have been reported in serial casting and splinting. Literature indicates surgical intervention when such nonoperative techniques and range-of-motion exercises fail. Here, we demonstrated a significant reduction of the contractures of the affected elbow and improvement in arm length to more normal after BTL in these patients, who had unsuccessful serial casting. Ten OBPI patients (6 girls and 4 boys) with an average age of 11.2 years (4-17.7 years) had BTL surgery after unsuccessful serial casting. Mean elbow flexion contracture was 40° before and 37° (average) after serial casting. Mean elbow flexion contracture was reduced to 8° (0°-20°) post-BTL surgical procedure with an average follow-up of 11 months. This was 75% improvement and statistically significant (P < .001) when compared to 7% insignificant (P = .08) improvement after serial casting. These OBPI patients in our study had 75% significant reduction in elbow flexion contractures and achieved an improved and more normal length of the affected arm after the BTL surgery when compared to only 7% insignificant reduction and no improvement in arm length after serial casting.
Structure of IgG and IgY molecules in ribosome-antibody complexes as studied by electron microscopy.
Noll, F; Lutsch, G; Bielka, H
1982-03-01
The overall shape and dimensions of IgG (rabbit) and IgY (chicken) antibodies against ribosomal proteins have been studied in electron micrographs of ribosome-antibody complexes. The antibodies appear as Y-shaped molecules with an angle of about 90 degrees between their Fab arms. The length of one Fab arm amounts to about 10 nm. No differences between the IgG and IgY molecules could be detected electron microscopically. The data obtained on the shape of IgG and IgY correlate with those of earlier electron microscopic studies while the determined size of the Fab arms is in the range found by scattering methods.
Using shape to turn off blinking for two-colour multiexciton emission in CdSe/CdS tetrapods
NASA Astrophysics Data System (ADS)
Mishra, Nimai; Orfield, Noah J.; Wang, Feng; Hu, Zhongjian; Krishnamurthy, Sachidananda; Malko, Anton V.; Casson, Joanna L.; Htoon, Han; Sykora, Milan; Hollingsworth, Jennifer A.
2017-05-01
Semiconductor nanostructures capable of emitting from two excited states and thereby of producing two photoluminescence colours are of fundamental and potential technological significance. In this limited class of nanocrystals, CdSe/CdS core/arm tetrapods exhibit the unusual trait of two-colour (red and green) multiexcitonic emission, with green emission from the CdS arms emerging only at high excitation fluences. Here we show that by synthetic shape-tuning, both this multi-colour emission process, and blinking and photobleaching behaviours of single tetrapods can be controlled. Specifically, we find that the properties of dual emission and single-nanostructure photostability depend on different structural parameters--arm length and arm diameter, respectively--but that both properties can be realized in the same nanostructure. Furthermore, based on results of correlated photoluminescence and transient absorption measurements, we conclude that hole-trap filling in the arms and partial state-filling in the core are necessary preconditions for the observation of multiexciton multi-colour emission.
Determination of sex by armbone dimensions.
Aye, Victor Omakoji
2010-06-15
Sex determination is a vital part of the medico-legal system but can be difficult in cases where the body is damaged. The purpose of this study was to develop a technique for sex determination from three arm-bone dimensions (wrist circumference, arm length and arm span). This knowledge can be applied in cases of mass disaster, homicide and events such as sports. Data were collected for 95 Nigerian male students and 90 Nigerian female students using physical anthropometry. Discriminant function presented the wrist dimension as the dominant contributor in this study. Combination equations for both the wrist and arm-span dimensions correctly classified sex (male/female) with an accuracy rate of 84.9%. On cross-validation, sex was also established with the same 84.9% accuracy rate. Sex determination was higher in males. Sexual dimorphism was established in this study, although the wrist circumference was more distinct than arm span; a combination of both generated sex with an accuracy prediction rate of 84.9%. (c) 2010 Elsevier Ireland Ltd. All rights reserved.
Using shape to turn off blinking for two-colour multiexciton emission in CdSe/CdS tetrapods
Mishra, Nimai; Orfield, Noah J.; Wang, Feng; Hu, Zhongjian; Krishnamurthy, Sachidananda; Malko, Anton V.; Casson, Joanna L.; Htoon, Han; Sykora, Milan; Hollingsworth, Jennifer A.
2017-01-01
Semiconductor nanostructures capable of emitting from two excited states and thereby of producing two photoluminescence colours are of fundamental and potential technological significance. In this limited class of nanocrystals, CdSe/CdS core/arm tetrapods exhibit the unusual trait of two-colour (red and green) multiexcitonic emission, with green emission from the CdS arms emerging only at high excitation fluences. Here we show that by synthetic shape-tuning, both this multi-colour emission process, and blinking and photobleaching behaviours of single tetrapods can be controlled. Specifically, we find that the properties of dual emission and single-nanostructure photostability depend on different structural parameters—arm length and arm diameter, respectively—but that both properties can be realized in the same nanostructure. Furthermore, based on results of correlated photoluminescence and transient absorption measurements, we conclude that hole-trap filling in the arms and partial state-filling in the core are necessary preconditions for the observation of multiexciton multi-colour emission. PMID:28497776
Muscle Hypertrophy in Prepubescent Tennis Players: A Segmentation MRI Study
Sanchis-Moysi, Joaquin; Idoate, Fernando; Serrano-Sanchez, Jose A.; Dorado, Cecilia; Calbet, Jose A. L.
2012-01-01
Purpose To asses if tennis at prepubertal age elicits the hypertrophy of dominant arm muscles. Methods The volume of the muscles of both arms was determined using magnetic resonance imaging (MRI) in 7 male prepubertal tennis players (TP) and 7 non-active control subjects (CG) (mean age 11.0±0.8 years, Tanner 1–2). Results TP had 13% greater total muscle volume in the dominant than in the contralateral arm. The magnitude of inter-arm asymmetry was greater in TP than in CG (13 vs 3%, P<0.001). The dominant arm of TP was 16% greater than the dominant arm of CG (P<0.01), whilst non-dominant arms had similar total muscle volumes in both groups (P = 0.25), after accounting for height as covariate. In TP, dominant deltoid (11%), forearm supinator (55%) and forearm flexors (21%) and extensors (25%) were hypertrophied compared to the contralateral arm (P<0.05). In CG, the dominant supinator muscle was bigger than its contralateral homonimous (63%, P<0.05). Conclusions Tennis at prepubertal age is associated with marked hypertrophy of the dominant arm, leading to a marked level of asymmetry (+13%), much greater than observed in non-active controls (+3%). Therefore, tennis particpation at prepubertal age is associated with increased muscle volumes in dominant compared to the non-dominant arm, likely due to selectively hypertrophy of the loaded muscles. PMID:22428074
Cortical Spiking Network Interfaced with Virtual Musculoskeletal Arm and Robotic Arm
Dura-Bernal, Salvador; Zhou, Xianlian; Neymotin, Samuel A.; Przekwas, Andrzej; Francis, Joseph T.; Lytton, William W.
2015-01-01
Embedding computational models in the physical world is a critical step towards constraining their behavior and building practical applications. Here we aim to drive a realistic musculoskeletal arm model using a biomimetic cortical spiking model, and make a robot arm reproduce the same trajectories in real time. Our cortical model consisted of a 3-layered cortex, composed of several hundred spiking model-neurons, which display physiologically realistic dynamics. We interconnected the cortical model to a two-joint musculoskeletal model of a human arm, with realistic anatomical and biomechanical properties. The virtual arm received muscle excitations from the neuronal model, and fed back proprioceptive information, forming a closed-loop system. The cortical model was trained using spike timing-dependent reinforcement learning to drive the virtual arm in a 2D reaching task. Limb position was used to simultaneously control a robot arm using an improved network interface. Virtual arm muscle activations responded to motoneuron firing rates, with virtual arm muscles lengths encoded via population coding in the proprioceptive population. After training, the virtual arm performed reaching movements which were smoother and more realistic than those obtained using a simplistic arm model. This system provided access to both spiking network properties and to arm biophysical properties, including muscle forces. The use of a musculoskeletal virtual arm and the improved control system allowed the robot arm to perform movements which were smoother than those reported in our previous paper using a simplistic arm. This work provides a novel approach consisting of bidirectionally connecting a cortical model to a realistic virtual arm, and using the system output to drive a robotic arm in real time. Our techniques are applicable to the future development of brain neuroprosthetic control systems, and may enable enhanced brain-machine interfaces with the possibility for finer control of limb prosthetics. PMID:26635598
Silva, Analiza M; Júdice, Pedro B; Carraça, Eliana V; King, Neil; Teixeira, Pedro J; Sardinha, Luís B
2018-06-01
Non-exercise physical activity (NEPA) and/or non-exercise activity thermogenesis (NEAT) reductions may occur from diet and/or exercise-induced negative energy balance interventions, resulting in less-than-expected weight loss. This systematic review describes the effects of prescribed diet and/or physical activity (PA)/exercise on NEPA and/or NEAT in adults. Studies were identified from PubMed, web-of-knowledge, Embase, SPORTDiscus, ERIC and PsycINFO searches up to 1 March 2017. Eligibility criteria included randomised controlled trials (RCT), randomised trials (RT) and non-randomised trials (NRT); objective measures of PA and energy expenditure; data on NEPA, NEAT and spontaneous PA; ≥10 healthy male/female aged>18 years; and ≥7 d length. The trial is registered at PROSPERO-2017-CRD42017052635. In all, thirty-six articles (RCT-10, RT-9, NRT-17) with a total of seventy intervention arms (diet, exercise, combined diet/exercise), with a total of 1561 participants, were included. Compensation was observed in twenty-six out of seventy intervention arms (fifteen studies out of thirty-six reporting declines in NEAT (eight), NEPA (four) or both (three)) representing 63, 27 and 23 % of diet-only, combined diet/exercise, and exercise-only intervention arms, respectively. Weight loss observed in participants who decreased NEAT was double the weight loss found in those who did not compensate, suggesting that the energy imbalance degree may lead to energy conservation. Although these findings do not support the hypothesis that prescribed diet and/or exercise results in decreased NEAT and NEPA in healthy adults, the underpowered trial design and the lack of state-of-the-art methods may limit these conclusions. Future studies should explore the impact of weight-loss magnitude, energetic restriction degree, exercise dose and participant characteristics on NEAT and/or NEPA.
NASA Astrophysics Data System (ADS)
Alcala, Yvonne; Olivecrona, Henrik; Olivecrona, Lotta; Noz, Marilyn E.; Maguire, Gerald Q., Jr.; Zeleznik, Michael P.; Sollerman, Christer
2005-04-01
The purpose of this study was to extend previous work to detect migration of total wrist arthroplasty non-invasively, and with greater accuracy. Two human cadaverous arms, each with a cemented total wrist implant, were used in this study. In one of the arms, 1 mm tantalum balls were implanted, six in the carpal bones and five in the radius. Five CT scans of each arm were acquired, changing the position of the arm each time to mimic different positions patients might take on repeated examinations. Registration of CT volume data sets was performed using an extensively validated, 3D semi-automatic volume fusion tool in which co-homologous point pairs (landmarks) are chosen on each volume to be registered. Three sets of ten cases each were obtained by placing landmarks on 1) bone only (using only arm one), 2) tantalum implants only, and 3) bone and tantalum implants (both using only arm two). The accuracy of the match was assessed visually in 2D and 3D, and numerically by calculating the distance difference between the actual position of the transformed landmarks and their ideal position (i.e., the reference landmark positions). All cases were matched visually within one width of cortical bone and numerically within one half CT voxel (0.32 mm, p = 0.05). This method matched only the bone/arm and not the prosthetic component per se, thus making it possible to detect prosthetic movement and wear. This method was clinically used for one patient with pain. Loosening of the carpal prosthetic component was accurately detected and this was confirmed at surgery.
Revisiting the anatomy and biomechanics of the anconeus muscle and its role in elbow stability.
Pereira, Barry P
2013-07-01
Recent studies have designated the anconeus muscle as an option for use as a pedicled flap for covering soft tissue defects about the elbow, with reported minimal risk of morbidity. This has raised the question as to the importance of the anconeus muscle and as to whether this is truly an accessory muscle that can be sacrificed, or whether the anconeus muscle significantly contributes to elbow and forearm stability? This study revisits the anatomy and biomechanics of the anconeus muscle and aims to investigate the neuromuscular compartments of the anconeus muscle and to determine the changes in the muscle length, fibre length and moment arm over a range of elbow flexion angles for each compartment. An anatomical study on 8 human cadavers (51-77 years of age) was done and a 2-dimensional kinematic elbow model developed to determine changes in the muscle length and moment arm of the muscle related to changes in elbow flexion angles. The muscle was modelled with two possible lines of action, one along the posterior and another on the anterior edge of the muscle as they had different muscle fibre lengths (posterior: average of 32 mm, anterior: average of 20 mm). The anterior edge also had an aponeurosis which was 70% of its length. From 0 to 120° elbow flexion, the length of the posterior and anterior edges increased with a maximum change recorded at 90° elbow flexion (31.7±1.0 mm and 65.3±1.4 mm, respectively). The moment arm is 14-mm at 0° flexion, but between the posterior and anterior edges it decreases at different rates with increasing elbow flexion angle. Beyond 80°, the anterior edge behaves as an elbow flexor, while the posterior edge remains an elbow extensor. The study demonstrates that the anconeus muscle has two neuromuscular compartments each with distinct intramuscular innervations and muscle fibre lengths. The posterior and deep aspect of the muscle functions as an elbow extensor decreasing in influence with increasing elbow flexion angle. The anterior superficial aspect which is adjacent and parallel to the lateral collateral ligaments, would most likely work in unison to provide constraint to the posterolateral stability of the elbow. Copyright © 2012. Published by Elsevier GmbH.
NASA Technical Reports Server (NTRS)
Parker, Jr., Allen R (Inventor); Chan, Hon Man (Inventor); Piazza, Anthony (Nino) (Inventor); Richards, William Lance (Inventor)
2014-01-01
A method and system for multiplexing a network of parallel fiber Bragg grating (FBG) sensor-fibers to a single acquisition channel of a closed Michelson interferometer system via a fiber splitter by distinguishing each branch of fiber sensors in the spatial domain. On each branch of the splitter, the fibers have a specific pre-determined length, effectively separating each branch of fiber sensors spatially. In the spatial domain the fiber branches are seen as part of one acquisition channel on the interrogation system. However, the FBG-reference arm beat frequency information for each fiber is retained. Since the beat frequency is generated between the reference arm, the effective fiber length of each successive branch includes the entire length of the preceding branch. The multiple branches are seen as one fiber having three segments where the segments can be resolved. This greatly simplifies optical, electronic and computational complexity, and is especially suited for use in multiplexed or branched OFS networks for SHM of large and/or distributed structures which need a lot of measurement points.
Williams, S B; Wilson, A M; Rhodes, L; Andrews, J; Payne, R C
2008-01-01
We provide quantitative anatomical data on the muscle–tendon architecture and geometry of the pelvic limb of an elite sprint athlete, the racing greyhound. Specifically, muscle masses, muscle lengths, fascicle lengths, pennation angles and muscle moment arms were measured. Maximum isometric force and power of muscles, the maximum muscle torque at joints and tendon stress and strain were estimated. We compare data with that published for a generalized breed of canid, and other cursorial mammals such as the horse and hare. The pelvic limb of the racing greyhound had a relatively large volume of hip extensor muscle, which is likely to be required for power production. Per unit body mass, some pelvic limb muscles were relatively larger than those in less specialized canines, and many hip extensor muscles had longer fascicle lengths. It was estimated that substantial extensor moments could be created about the tarsus and hip of the greyhound allowing high power output and potential for rapid acceleration. The racing greyhound hence possesses substantial specializations for enhanced sprint performance. PMID:18657259
Williams, S B; Wilson, A M; Rhodes, L; Andrews, J; Payne, R C
2008-10-01
We provide quantitative anatomical data on the muscle-tendon architecture and geometry of the pelvic limb of an elite sprint athlete, the racing greyhound. Specifically, muscle masses, muscle lengths, fascicle lengths, pennation angles and muscle moment arms were measured. Maximum isometric force and power of muscles, the maximum muscle torque at joints and tendon stress and strain were estimated. We compare data with that published for a generalized breed of canid, and other cursorial mammals such as the horse and hare. The pelvic limb of the racing greyhound had a relatively large volume of hip extensor muscle, which is likely to be required for power production. Per unit body mass, some pelvic limb muscles were relatively larger than those in less specialized canines, and many hip extensor muscles had longer fascicle lengths. It was estimated that substantial extensor moments could be created about the tarsus and hip of the greyhound allowing high power output and potential for rapid acceleration. The racing greyhound hence possesses substantial specializations for enhanced sprint performance.
The Future of Officer Career Development System in the Slovenian Armed Forces
2013-12-13
Professors Anton Zabkar and Uros Svete, at the Faculty for Social Science at University of Ljubljana, clearly identified the deficiencies in the...short-lived solution], Slovenian Armed Forces Bulletin 10, no. 1 (May 2008): 97-120. 5Anton Zabkar and Uros Svete, “Solanje Vojaskih Profesionalcev...is based on Length of Service ( LoS ) and applies to all DE officers and the other is the LE career structure.87 85Major Al Thorp, e-mail message to
Neural Network Grasping Controller for Continuum Robots
2006-01-01
string encoders attached to the base of section 1 and optical encoders located at the end plates of section 1 and 2. The cables from each of the...string encoders run the entire length of the arm through the optical encoders at the lower sections, as seen in Figure 1. This configuration enables the...encoders at the base section and the optical encoders at the end plates of the distal sections, there were a number of protrusions on the surface of the arm
A new method for the adjustment of neochordal length: the adjustable slip knot technique.
Yano, Mitsuhiro; Sakaguchi, Syuuhei; Furukawa, Kohji; Nakamura, Eisaku
2015-08-01
The use of expanded polytetrafluoroethylene (ePTFE) sutures for the correction of mitral valve prolapse has become a standardized procedure. Adjustment of neochordal length is crucial to the efficacy of this technique. Various methods have been described for this purpose; however, the fine adjustment of neochordal length is technically challenging. We describe a simple and effective technique for the implantation of neochordae, which we have termed the 'adjustable slip knot technique'. The first step of this technique is reinforcement of the papillary muscle by a Teflon pledget with or without polytetrafluoroethylene (CV-4) loops. The second step is the formation of a neochordal loop by introducing an ePTFE suture between the affected mitral leaflet and the papillary muscle or ePTFE loops. The third step is the adjustment of the length of neochordae. The formation of a slip knot in one arm of the ePTFE suture is the pivot of this technique. The neochordal loop can be constricted by the application of tension to one arm of the suture. We applied this technique in 5 patients with satisfactory results. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Ankle taping can reduce external ankle joint moments during drop landings on a tilted surface.
Sato, Nahoko; Nunome, Hiroyuki; Hopper, Luke S; Ikegami, Yasuo
2017-09-20
Ankle taping is commonly used to prevent ankle sprains. However, kinematic assessments investigating the biomechanical effects of ankle taping have provided inconclusive results. This study aimed to determine the effect of ankle taping on the external ankle joint moments during a drop landing on a tilted surface at 25°. Twenty-five participants performed landings on a tilted force platform that caused ankle inversion with and without ankle taping. Landing kinematics were captured using a motion capture system. External ankle inversion moment, the angular impulse due to the medio-lateral and vertical components of ground reaction force (GRF) and their moment arm lengths about the ankle joint were analysed. The foot plantar inclination relative to the ground was assessed. In the taping condition, the foot plantar inclination and ankle inversion angular impulse were reduced significantly compared to that of the control. The only component of the external inversion moment to change significantly in the taped condition was a shortened medio-lateral GRF moment arm length. It can be assumed that the ankle taping altered the foot plantar inclination relative to the ground, thereby shortening the moment arm of medio-lateral GRF that resulted in the reduced ankle inversion angular impulse.
Caçola, Priscila; Ibana, Melvin; Ricard, Mark; Gabbard, Carl
2016-01-01
Coincident timing or interception ability can be defined as the capacity to precisely time sensory input and motor output. This study compared accuracy of typically developing (TD) children and those with Developmental Coordination Disorder (DCD) on a task involving estimation of coincident timing with their arm and various tool lengths. Forty-eight (48) participants performed two experiments where they imagined intercepting a target moving toward (Experiment 1) and target moving away (Experiment 2) from them in 5 conditions with their arm and tool lengths: arm, 10, 20, 30, and 40 cm. In Experiment 1, the DCD group overestimated interception points approximately twice as much as the TD group, and both groups overestimated consistently regardless of the tool used. Results for Experiment 2 revealed that those with DCD underestimated about three times as much as the TD group, with the exception of when no tool was used. Overall, these results indicate that children with DCD are less accurate with estimation of coincident-timing; which might in part explain their difficulties with common motor activities such as catching a ball or striking a baseball pitch. Copyright © 2015 Elsevier Ltd. All rights reserved.
Maganaris, Constantinos N; Baltzopoulos, Vasilios; Sargeant, Anthony J
1998-01-01
The purpose of the present study was to examine the effect of a plantarflexor maximum voluntary contraction (MVC) on Achilles tendon moment arm length. Sagittal magnetic resonance (MR) images of the right ankle were taken in six subjects both at rest and during a plantarflexor MVC in the supine position at a knee angle of 90 deg and at ankle angles of -30 deg (dorsiflexed direction), -15 deg, 0 deg (neutral ankle position), +15 deg (plantarflexed direction), +30 deg and +45 deg. A system of mechanical stops, support triangles and velcro straps was used to secure the subject in the above positions. Location of a moving centre of rotation was calculated for ankle rotations from -30 to 0 deg, -15 to +15 deg, 0 to +30 deg and +15 to +45 deg. All instant centres of rotation were calculated both at rest and during MVC. Achilles tendon moment arms were measured at ankle angles of -15, 0, +15 and +30 deg. At any given ankle angle, Achilles tendon moment arm length during MVC increased by 1-1.5 cm (22-27%, P < 0.01) compared with rest. This was attributed to a displacement of both Achilles tendon by 0.6-1.1 cm (P < 0.01) and all instant centres of rotation by about 0.3 cm (P < 0.05) away from their corresponding resting positions. The findings of this study have important implications for estimating loads in the musculoskeletal system. Substantially unrealistic Achilles tendon forces and moments generated around the ankle joint during a plantarflexor MVC would be calculated using resting Achilles tendon moment arm measurements. PMID:9660906
Maganaris, C N; Baltzopoulos, V; Sargeant, A J
1998-08-01
1. The purpose of the present study was to examine the effect of a plantarflexor maximum voluntary contraction (MVC) on Achilles tendon moment arm length. 2. Sagittal magnetic resonance (MR) images of the right ankle were taken in six subjects both at rest and during a plantarflexor MVC in the supine position at a knee angle of 90 deg and at ankle angles of -30 deg (dorsiflexed direction), -15 deg, 0 deg (neutral ankle position), +15 deg (plantarflexed direction), +30 deg and +45 deg. A system of mechanical stops, support triangles and velcro straps was used to secure the subject in the above positions. Location of a moving centre of rotation was calculated for ankle rotations from -30 to 0 deg, -15 to +15 deg, 0 to +30 deg and +15 to +45 deg. All instant centres of rotation were calculated both at rest and during MVC. Achilles tendon moment arms were measured at ankle angles of -15, 0, +15 and +30 deg. 3. At any given ankle angle, Achilles tendon moment arm length during MVC increased by 1-1.5 cm (22-27 %, P < 0.01) compared with rest. This was attributed to a displacement of both Achilles tendon by 0.6-1.1 cm (P < 0.01) and all instant centres of rotation by about 0.3 cm (P < 0.05) away from their corresponding resting positions. 4. The findings of this study have important implications for estimating loads in the musculoskeletal system. Substantially unrealistic Achilles tendon forces and moments generated around the ankle joint during a plantarflexor MVC would be calculated using resting Achilles tendon moment arm measurements.
Ustinova, Ksenia I; Langenderfer, Joseph E; Balendra, Nilanthy
2017-04-01
The current study investigated interlimb coordination in individuals with traumatic brain injury (TBI) during overground walking. The study involved 10 participants with coordination, balance, and gait abnormalities post-TBI, as well as 10 sex- and age-matched healthy control individuals. Participants walked 12m under two experimental conditions: 1) at self-selected comfortable walking speeds; and 2) with instructions to increase the amplitude and out-of-phase coordination of arm swinging. The gait was assessed with a set of spatiotemporal and kinematic parameters including the gait velocity, step length and width, double support time, lateral displacement of the center of mass, the amplitude of horizontal trunk rotation, and angular motions at shoulder and hip joints in sagittal plane. Interlimb coordination (coupling) was analyzed as the relative phase angles between the left and right shoulders, hips, and contralateral shoulders and hips, with an ideal out-of-phase coupling of 180° and ideal in-phase coupling of 0°. The TBI group showed much less interlimb coupling of the above pairs of joint motions than the control group. When participants were required to increase and synchronize arm swinging, coupling between shoulder and hip motions was significantly improved in both groups. Enhanced arm swinging was associated with greater hip and shoulder motion amplitudes, and greater step length. No other significant changes in spatiotemporal or kinematic gait characteristics were found in either group. The results suggest that arm swinging may be a gait parameter that, if controlled properly, can improve interlimb coordination during overground walking in patients with TBI. Copyright © 2017 Elsevier B.V. All rights reserved.
Byrne, Maria; Lamare, Miles; Winter, David; Dworjanyn, Symon A; Uthicke, Sven
2013-01-01
The stunting effect of ocean acidification on development of calcifying invertebrate larvae has emerged as a significant effect of global change. We assessed the arm growth response of sea urchin echinoplutei, here used as a proxy of larval calcification, to increased seawater acidity/pCO2 and decreased carbonate mineral saturation in a global synthesis of data from 15 species. Phylogenetic relatedness did not influence the observed patterns. Regardless of habitat or latitude, ocean acidification impedes larval growth with a negative relationship between arm length and increased acidity/pCO2 and decreased carbonate mineral saturation. In multiple linear regression models incorporating these highly correlated parameters, pCO2 exerted the greatest influence on decreased arm growth in the global dataset and also in the data subsets for polar and subtidal species. Thus, reduced growth appears largely driven by organism hypercapnia. For tropical species, decreased carbonate mineral saturation was most important. No single parameter played a dominant role in arm size reduction in the temperate species. For intertidal species, the models were equivocal. Levels of acidification causing a significant (approx. 10-20+%) reduction in arm growth varied between species. In 13 species, reduction in length of arms and supporting skeletal rods was evident in larvae reared in near-future (pCO2 800+ µatm) conditions, whereas greater acidification (pCO2 1000+ µatm) reduced growth in all species. Although multi-stressor studies are few, when temperature is added to the stressor mix, near-future warming can reduce the negative effect of acidification on larval growth. Broadly speaking, responses of larvae from across world regions showed similar trends despite disparate phylogeny, environments and ecology. Larval success may be the bottleneck for species success with flow-on effects for sea urchin populations and marine ecosystems.
Byrne, Maria; Lamare, Miles; Winter, David; Dworjanyn, Symon A.; Uthicke, Sven
2013-01-01
The stunting effect of ocean acidification on development of calcifying invertebrate larvae has emerged as a significant effect of global change. We assessed the arm growth response of sea urchin echinoplutei, here used as a proxy of larval calcification, to increased seawater acidity/pCO2 and decreased carbonate mineral saturation in a global synthesis of data from 15 species. Phylogenetic relatedness did not influence the observed patterns. Regardless of habitat or latitude, ocean acidification impedes larval growth with a negative relationship between arm length and increased acidity/pCO2 and decreased carbonate mineral saturation. In multiple linear regression models incorporating these highly correlated parameters, pCO2 exerted the greatest influence on decreased arm growth in the global dataset and also in the data subsets for polar and subtidal species. Thus, reduced growth appears largely driven by organism hypercapnia. For tropical species, decreased carbonate mineral saturation was most important. No single parameter played a dominant role in arm size reduction in the temperate species. For intertidal species, the models were equivocal. Levels of acidification causing a significant (approx. 10–20+%) reduction in arm growth varied between species. In 13 species, reduction in length of arms and supporting skeletal rods was evident in larvae reared in near-future (pCO2 800+ µatm) conditions, whereas greater acidification (pCO2 1000+ µatm) reduced growth in all species. Although multi-stressor studies are few, when temperature is added to the stressor mix, near-future warming can reduce the negative effect of acidification on larval growth. Broadly speaking, responses of larvae from across world regions showed similar trends despite disparate phylogeny, environments and ecology. Larval success may be the bottleneck for species success with flow-on effects for sea urchin populations and marine ecosystems. PMID:23980242
Interferometric Polarization Control
NASA Technical Reports Server (NTRS)
Wollack, Edward J. (Inventor); Moseley, Samuel H. (Inventor); Chuss, David T. (Inventor); Novak, Giles A. (Inventor)
2008-01-01
A signal conditioning module provides a polarimeter capability in a photometric system. The module may include multiple variable delay polarization modulators. Each modulator may include an input port, and a first arm formed to include a first reflector and first rooftop mirror arranged in opposed relationship. The first reflector may direct an input radiation signal to the first rooftop mirror. Each modulator also may include an output port and a second arm formed to include a second reflector and second rooftop mirror arranged in opposed relationship. The second reflector can guide a signal from the second rooftop mirror towards the output port to provide an output radiation signal. A beamsplitting grid may be placed between the first reflector and the first rooftop mirror, and also between the second reflector and the second rooftop mirror. A translation apparatus can provide adjustment relative to optical path length vis-a-vis the first arm, the second arm and the grid.
Interferometric polarization control
NASA Technical Reports Server (NTRS)
Wollack, Edward J. (Inventor); Novak, Giles A. (Inventor); Moseley, Samuel H. (Inventor); Chuss, David T. (Inventor)
2009-01-01
A signal conditioning module provides a polarimeter capability in a photometric system. The module may include multiple variable delay polarization modulators. Each modulator may include an input port, and a first arm formed to include a first reflector and first rooftop mirror arranged in opposed relationship. The first reflector may direct an input radiation signal to the first rooftop mirror. Each modulator also may include an output port and a second arm formed to include a second reflector and second rooftop mirror arranged in opposed relationship. The second reflector can guide a signal from the second rooftop mirror towards the output port to provide an output radiation signal. A beamsplitting grid may be placed between the first reflector and the first rooftop mirror, and also between the second reflector and the second rooftop mirror. A translation apparatus can provide adjustment relative to optical path length vis-a-vis the first arm, the second arm and the grid.
Stable nonlinear Mach-Zehnder fiber switch
Digonnet, Michel J. F.; Shaw, H. John; Pantell, Richard H.; Sadowski, Robert W.
1999-01-01
An all-optical fiber switch is implemented within a short Mach-Zehnder interferometer configuration. The Mach-Zehnder switch is constructed to have a high temperature stability so as to minimize temperature gradients and other thermal effects which result in undesirable instability at the output of the switch. The Mach-Zehnder switch of the preferred embodiment is advantageously less than 2 cm in length between couplers to be sufficiently short to be thermally stable, and full switching is accomplished by heavily doping one or both of the arms between the couplers so as to provide a highly nonlinear region within one or both of the arms. A pump input source is used to affect the propagation characteristics of one of the arms to control the output coupling ratio of the switch. Because of the high nonlinearity of the pump input arm, low pump powers can be used, thereby alleviating difficulties and high cost associated with high pump input powers.
Flax, Valerie L.; Bentley, Margaret E.; Chasela, Charles S.; Kayira, Dumbani; Hudgens, Michael G.; Knight, Rodney J.; Soko, Alice; Jamieson, Denise J.; van der Horst, Charles M.; Adair, Linda S.
2012-01-01
The Breastfeeding, Antiretrovirals, and Nutrition Study evaluated the effect of daily consumption of lipid-based nutrient supplements (LNS) by 2121 lactating, HIV-infected mothers on the growth of their exclusively breast-fed, HIV-uninfected infants from 0 to 24 wk. The study had a 2 × 3 factorial design. Malawian mothers with CD4+ ≥250 cells/mm3, hemoglobin ≥70 g/L, and BMI ≥17 kg/m2 were randomized within 36 h of delivery to receive either no LNS or 140 g/d of LNS to meet lactation energy and protein needs, and mother-infant pairs were assigned to maternal antiretroviral drugs (ARV), infant ARV, or no ARV. Sex-stratified, longitudinal, random effects models were used to estimate the effect of the 6 study arms on infant weight, length, and BMI. Logistic regression models were used to calculate the odds of growth faltering [decline in weight-for-age Z-score (WAZ) or length-for-age Z-score (LAZ) >0.67] using the control arm as the reference. Although some differences between study arms emerged with increasing infant age in boys, there were no consistent effects of the maternal supplement across the 3 growth outcomes in longitudinal models. At the ages where differences were observed, the effects on weight and BMI were quite small (≤200 g and ≤0.4 kg/m2) and unlikely to be of clinical importance. Overall, 21 and 34% of infants faltered in WAZ and LAZ, respectively. Maternal supplementation did not reduce the odds of infant weight or length faltering from 0 to 24 wk in any arm. These results indicate that blanket supplementation of HIV-infected lactating women may have little impact on infant growth. PMID:22649265
Murakami, Satoshi; Minami-Ohtsubo, Maki; Nakato, Ryuichiro; Shirahige, Katsuhiko; Tabata, Tetsuya
2017-05-31
Multiple components have been identified that exhibit different stabilities for aversive olfactory memory in Drosophila These components have been defined by behavioral and genetic studies and genes specifically required for a specific component have also been identified. Intermediate-term memory generated after single cycle conditioning is divided into anesthesia-sensitive memory (ASM) and anesthesia-resistant memory (ARM), with the latter being more stable. We determined that the ASM and ARM pathways converged on the Rgk1 small GTPase and that the N-terminal domain-deleted Rgk1 was sufficient for ASM formation, whereas the full-length form was required for ARM formation. Rgk1 is specifically accumulated at the synaptic site of the Kenyon cells (KCs), the intrinsic neurons of the mushroom bodies, which play a pivotal role in olfactory memory formation. A higher than normal Rgk1 level enhanced memory retention, which is consistent with the result that Rgk1 suppressed Rac-dependent memory decay; these findings suggest that rgk1 bolsters ASM via the suppression of forgetting. We propose that Rgk1 plays a pivotal role in the regulation of memory stabilization by serving as a molecular node that resides at KC synapses, where the ASM and ARM pathway may interact. SIGNIFICANCE STATEMENT Memory consists of multiple components. Drosophila olfactory memory serves as a fundamental model with which to investigate the mechanisms that underlie memory formation and has provided genetic and molecular means to identify the components of memory, namely short-term, intermediate-term, and long-term memory, depending on how long the memory lasts. Intermediate memory is further divided into anesthesia-sensitive memory (ASM) and anesthesia-resistant memory (ARM), with the latter being more stable. We have identified a small GTPase in Drosophila , Rgk1, which plays a pivotal role in the regulation of olfactory memory stability. Rgk1 is required for both ASM and ARM. Moreover, N-terminal domain-deleted Rgk1 was sufficient for ASM formation, whereas the full-length form was required for ARM formation. Copyright © 2017 the authors 0270-6474/17/375496-•$15.00/0.
Canda, Alicia
2009-03-01
Knowledge of stature is necessary for evaluating nutritional status and for correcting certain functional parameters. Measuring stature is difficult or impossible in bedridden or wheelchair-bound persons and may also be diminished by disorders of the spinal column or extremities. The purpose of this work is to develop estimation equations for young adult athletes for their subsequent application to disabled persons. The main sample comprised 445 male and 401 female sportspersons. Cross validation was also performed on 100 males and 101 females. All were Caucasian, the males being over 21 and the females over 18, and all practiced some kind of sport. The following variables were included: stature, sitting height, arm span, and lengths of upper arm, forearm, hand, thigh, lower leg, and foot. Simple and multiple regression analyses were performed using stature as a dependent variable and the others as predictive variables. The best equation for males (R(2)=0.978; RMSE=1.41 cm; PE=1.54 cm) was stature: 1.346+1.023 * lower leg+0.957 * sitting height+0.530 * thigh+0.493 * upper arm+0.228 * forearm. For females (R(2)=0.959; RMSE=1.57 cm; PE=1.25 cm) it was stature: 1.772+0.159 * arm span+0.957 * sitting height+0.424 * thigh+0.966 * lower leg. Alternative equations were developed for when a particular variable cannot be included for reasons of mobility, technical difficulty, or segment loss.
Octopus-inspired multi-arm robotic swimming.
Sfakiotakis, M; Kazakidi, A; Tsakiris, D P
2015-05-13
The outstanding locomotor and manipulation characteristics of the octopus have recently inspired the development, by our group, of multi-functional robotic swimmers, featuring both manipulation and locomotion capabilities, which could be of significant engineering interest in underwater applications. During its little-studied arm-swimming behavior, as opposed to the better known jetting via the siphon, the animal appears to generate considerable propulsive thrust and rapid acceleration, predominantly employing movements of its arms. In this work, we capture the fundamental characteristics of the corresponding complex pattern of arm motion by a sculling profile, involving a fast power stroke and a slow recovery stroke. We investigate the propulsive capabilities of a multi-arm robotic system under various swimming gaits, namely patterns of arm coordination, which achieve the generation of forward, as well as backward, propulsion and turning. A lumped-element model of the robotic swimmer, which considers arm compliance and the interaction with the aquatic environment, was used to study the characteristics of these gaits, the effect of various kinematic parameters on propulsion, and the generation of complex trajectories. This investigation focuses on relatively high-stiffness arms. Experiments employing a compliant-body robotic prototype swimmer with eight compliant arms, all made of polyurethane, inside a water tank, successfully demonstrated this novel mode of underwater propulsion. Speeds of up to 0.26 body lengths per second (approximately 100 mm s(-1)), and propulsive forces of up to 3.5 N were achieved, with a non-dimensional cost of transport of 1.42 with all eight arms and of 0.9 with only two active arms. The experiments confirmed the computational results and verified the multi-arm maneuverability and simultaneous object grasping capability of such systems.
Mohler, Volker; Zeller, Friedrich J; Hsam, Sai L K
2012-05-01
Powdery mildew is a prevalent fungal disease affecting oat (Avena sativa L.) production in Europe. Common oat cultivar Rollo was previously shown to carry the powdery mildew resistance gene Eg-3 in common with cultivar Mostyn. The resistance gene was mapped with restriction fragment length polymorphism (RFLP) markers from Triticeae group-1 chromosomes using a population of F(3) lines from a cross between A. byzantina cv. Kanota and A. sativa cv. Rollo. This comparative mapping approach positioned Eg-3 between cDNA-RFLP marker loci cmwg706 and cmwg733. Since both marker loci were derived from the long arm of barley chromosome 1H, the subchromosomal location of Eg-3 was assumed to be on the long arm of oat chromosome 17. Amplified fragment length polymorphism (AFLP) marker technology featured as an efficient means for obtaining markers closely linked to Eg-3.
Fetal tele-echography using a robotic arm and a satellite link.
Arbeille, P; Ruiz, J; Herve, P; Chevillot, M; Poisson, G; Perrotin, F
2005-09-01
To design a method for conducting fetal ultrasound examinations in isolated hospital sites using a dedicated remotely controlled robotic arm (tele-echography). Tele-echography was performed from our hospital (expert center) on 29 pregnant women in an isolated maternity hospital (patient site) 1700 km away, and findings were compared with those of conventional ultrasound examinations. At the patient site, a robotic arm holding the real ultrasound probe was placed on the patient's abdomen by an assistant with no experience of performing ultrasound. The robotic arm, remotely controlled with a fictive (expert) probe, reproduced the exact movements (tilting and rotating) of the expert hand on the real ultrasound probe. In 93.1% of the cases, all biometric parameters, placental location and amniotic fluid volume, were correctly assessed using the teleoperated robotic arm. In two cases, femur length could not be correctly measured. The mean duration of fetal ultrasound examination was 14 min (range, 10-18) and 18 min (range, 13-23) by conventional and tele-echography methods, respectively. The mean number of times the robotic arm was repositioned on the patient's abdomen was seven (range, 5-9). Tele-echography using a robotic arm provides the main information needed to assess fetal growth and the intrauterine environment within a limited period of time.
Modal kinematics for multisection continuum arms.
Godage, Isuru S; Medrano-Cerda, Gustavo A; Branson, David T; Guglielmino, Emanuele; Caldwell, Darwin G
2015-05-13
This paper presents a novel spatial kinematic model for multisection continuum arms based on mode shape functions (MSF). Modal methods have been used in many disciplines from finite element methods to structural analysis to approximate complex and nonlinear parametric variations with simple mathematical functions. Given certain constraints and required accuracy, this helps to simplify complex phenomena with numerically efficient implementations leading to fast computations. A successful application of the modal approximation techniques to develop a new modal kinematic model for general variable length multisection continuum arms is discussed. The proposed method solves the limitations associated with previous models and introduces a new approach for readily deriving exact, singularity-free and unique MSF's that simplifies the approach and avoids mode switching. The model is able to simulate spatial bending as well as straight arm motions (i.e., pure elongation/contraction), and introduces inverse position and orientation kinematics for multisection continuum arms. A kinematic decoupling feature, splitting position and orientation inverse kinematics is introduced. This type of decoupling has not been presented for these types of robotic arms before. The model also carefully accounts for physical constraints in the joint space to provide enhanced insight into practical mechanics and impose actuator mechanical limitations onto the kinematics thus generating fully realizable results. The proposed method is easily applicable to a broad spectrum of continuum arm designs.
Korellis, J.S.
1986-08-12
A self-gauging extensometer assembly for measuring axial strain of a test specimen through the wall of a high temperature furnace comprises an extensometer having a pair of telescoping arms carrying jaws that clip to the specimen at points spaced apart from each other by a predetermined gauge length. The jaws, which open parallel to the longitudinal axis of the telescoping arms, are biased closed into contact with opposite sides of the specimen by helical springs. A knife edge formed in each jaw prevents any slippage of the specimen between jaws during measurements. Because the jaws of the telescoping arms require no lateral pivoting, to open or close, the assembly is able to be clipped to a specimen through a relatively small opening in the furnace wall.
NASA Astrophysics Data System (ADS)
Watson, Judith J.
1992-08-01
An astronaut monorail system (AMS) is presented as a vehicle to transport and position EVA astronauts along large space truss structures. The AMS is proposed specifically as an alternative to the crew and equipment transfer aid for Space Station Freedom. Design considerations for the AMS were discussed and a reference configuration was selected for the study. Equations were developed to characterize the stiffness and frequency behavior of the AMS positioning arm. Experimental data showed that these equations gave a fairly accurate representation of the stiffness and frequency behavior of the arm. A study was presented to show trends for the arm behavior based on varying parameters of the stiffness and frequency equations. An ergonomics study was conducted to provide boundary conditions for tolerable frequency and deflection to be used in developing a design concept for the positioning arm. The feasibility of the AMS positioning arm was examined using equations and working curves developed in this study. It was found that a positioning arm of a length to reach all interior points of the space station truss structure could not be designed to satisfy frequency and deflection constraints. By relaxing the design requirements and the ergonomic boundaries, an arm could be designed which would provide a stable work platform for the EVA astronaut and give him access to over 75 percent of the truss interior.
Döring, Jessica
2017-01-01
Abstract Branchpoint nucleotides of intron lariats induce pausing of DNA synthesis by reverse transcriptases (RTs), but it is not known yet how they direct RT RNase H activity on branched RNA (bRNA). Here, we report the effects of the two arms of bRNA on branchpoint-directed RNA cleavage and mutation produced by Moloney murine leukemia virus (M-MLV) RT during DNA polymerization. We constructed a long-chained bRNA template by splinted-ligation. The bRNA oligonucleotide is chimeric and contains DNA to identify RNA cleavage products by probe hybridization. Unique sequences surrounding the branchpoint facilitate monitoring of bRNA purification by terminal-restriction fragment length polymorphism analysis. We evaluate the M-MLV RT-generated cleavage and mutational patterns. We find that cleavage of bRNA and misprocessing of the branched nucleotide proceed arm-specifically. Bypass of the branchpoint from the 2΄-arm causes single-mismatch errors, whereas bypass from the 3΄-arm leads to deletion mutations. The non-template arm is cleaved when reverse transcription is primed from the 3΄-arm but not from the 2΄-arm. This suggests that RTs flip ∼180° at branchpoints and RNases H cleave the non-template arm depending on its accessibility. Our observed interplay between M-MLV RT and bRNA would be compatible with a bRNA-mediated control of retroviral and related retrotransposon replication. PMID:28160599
Determinants of linear growth in Malaysian children with cerebral palsy.
Zainah, S H; Ong, L C; Sofiah, A; Poh, B K; Hussain, I H
2001-08-01
To compare the linear growth and nutritional parameters of a group of Malaysian children with cerebral palsy (CP) against a group of controls, and to determine the nutritional, medical and sociodemographic factors associated with poor growth in children with CP. The linear growth of 101 children with CP and of their healthy controls matched for age, sex and ethnicity was measured using upper-arm length (UAL). Nutritional parameters of weight, triceps skin-fold thickness and mid-arm circumference were also measured. Total caloric intake was assessed using a 24-h recall of a 3-day food intake and calculated as a percentage of the Recommended Daily Allowance. Multiple regression analysis was used to determine nutritional, medical and sociodemographic factors associated with poor growth (using z-scores of UAL) in children with CP. Compared with the controls, children with CP had significantly lower mean UAL measurements (difference between means -1.1, 95% confidence interval -1.65 to - 0.59), weight (difference between means -6.0, 95% CI -7.66 to -4.34), mid-arm circumference (difference between means -1.3, 95% CI -2.06 to -0.56) and triceps skin-fold thickness (difference between means -2.5, 95% CI -3.5 to -1.43). Factors associated with low z-scores of UAL were a lower percentage of median weight (P < 0.001), tube feeding (P < 0.001) and increasing age (P < 0.001). A large proportion of Malaysian children with CP have poor nutritional status and linear growth. Nutritional assessment and management at an early age might help this group of children achieve adequate growth.
76 FR 43662 - 36(b)(1) Arms Sales Notification
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-21
... and control systems with modern technology. The new guidance and control system uses a mixture of... Issuance of Letter of Offer Pursuant to Section 36(b)(1) of the Arms Export Control Act, as amended (i... million TOTAL $86 million * as defined in Section 47(6) of the Arms Export Control Act. (iii) Description...
Roy, Tracey Ann; Blackman, Marc R; Harman, S Mitchell; Tobin, Jordan D; Schrager, Matthew; Metter, E Jeffery
2002-08-01
Muscle mass and strength losses during aging may be associated with declining levels of serum testosterone (T) in men. Few studies have shown a direct relationship between T and muscle mass and strength. Subjects were 262 men, aged 24-90 yr, from the Baltimore Longitudinal Study of Aging, who had T and sex hormone-binding globulin sex hormone-binding globulin (SHBG) measurements, from which the free T index (FTI) was calculated (T/SHBG) from serum samples collected longitudinally since 1963, total body fat mass and arm and leg fat-free mass (FFM) by dual-energy X-ray absorptiometry and arm and leg strength by dynanomometry. Mixed-effects models estimated T and FTI at the time of mass and strength measurements. Age, total body fat, arm and leg FFM, T, and FTI were significantly associated with concentric and eccentric strength. FTI, not T, was modestly, but directly, related to arm and leg strength after fat, arm and leg FFM, height, and age were accounted for and indirectly through body mass. FTI is a better predictor of arm and leg strength than T in aging men.
Sivan, Manoj; Gallagher, Justin; Makower, Sophie; Keeling, David; Bhakta, Bipin; O'Connor, Rory J; Levesley, Martin
2014-12-12
Home-based robotic technologies may offer the possibility of self-directed upper limb exercise after stroke as a means of increasing the intensity of rehabilitation treatment. The current literature has a paucity of robotic devices that have been tested in a home environment. The aim of this research project was to evaluate a robotic device Home-based Computer Assisted Arm Rehabilitation (hCAAR) that can be used independently at home by stroke survivors with upper limb weakness. hCAAR device comprises of a joystick handle moved by the weak upper limb to perform tasks on the computer screen. The device provides assistance to the movements depending on users ability. Nineteen participants (stroke survivors with upper limb weakness) were recruited. Outcome measures performed at baseline (A0), at end of 8-weeks of hCAAR use (A1) and 1 month after end of hCAAR use (A2) were: Optotrak kinematic variables, Fugl Meyer Upper Extremity motor subscale (FM-UE), Action Research Arm Test (ARAT), Medical Research Council (MRC) and Modified Ashworth Scale (MAS), Chedoke Arm and Hand Activity Inventory (CAHAI) and ABILHAND. Two participants were unable to use hCAAR: one due to severe paresis and the other due to personal problems. The remaining 17 participants were able to use the device independently in their home setting. No serious adverse events were reported. The median usage time was 433 minutes (IQR 250 - 791 min). A statistically significant improvement was observed in the kinematic and clinical outcomes at A1. The median gain in the scores at A1 were by: movement time 19%, path length 15% and jerk 19%, FM-UE 1 point, total MAS 1.5 point, total MRC 2 points, ARAT 3 points, CAHAI 5.5 points and ABILHAND 3 points. Three participants showed clinically significant improvement in all the clinical outcomes. The hCAAR feasibility study is the first clinical study of its kind reported in the current literature; in this study, 17 participants used the robotic device independently for eight weeks in their own homes with minimal supervision from healthcare professionals. Statistically significant improvements were observed in the kinematic and clinical outcomes in the study.
Somasundaram, Chandra
2016-01-01
Objective: Assessment of surgical outcomes of biceps tendon lengthening (BTL) surgery in obstetric brachial plexus injury (OBPI) patients with elbow flexion contractures, who had unsuccessful serial casting. Background: Serial casting and splinting have been shown to be effective in correcting elbow flexion contractures in OBPI. However, the possibilities of radial head dislocations and other complications have been reported in serial casting and splinting. Literature indicates surgical intervention when such nonoperative techniques and range-of-motion exercises fail. Here, we demonstrated a significant reduction of the contractures of the affected elbow and improvement in arm length to more normal after BTL in these patients, who had unsuccessful serial casting. Methods and Patients: Ten OBPI patients (6 girls and 4 boys) with an average age of 11.2 years (4-17.7 years) had BTL surgery after unsuccessful serial casting. Results: Mean elbow flexion contracture was 40° before and 37° (average) after serial casting. Mean elbow flexion contracture was reduced to 8° (0°-20°) post-BTL surgical procedure with an average follow-up of 11 months. This was 75% improvement and statistically significant (P < .001) when compared to 7% insignificant (P = .08) improvement after serial casting. Conclusion: These OBPI patients in our study had 75% significant reduction in elbow flexion contractures and achieved an improved and more normal length of the affected arm after the BTL surgery when compared to only 7% insignificant reduction and no improvement in arm length after serial casting. PMID:27648115
2013-01-01
Background Achieving Millennium Development Goal 4 is dependent on significantly reducing neonatal mortality. Low birth weight is an underlying factor in most neonatal deaths. In developing countries the missed opportunity for providing life saving care is mainly a result of failure to identify low birth weight newborns. This study aimed at identifying a reliable anthropometric measurement for screening low birth weight and determining an operational cut-off point in the Uganda setting. This simple measurement is required because of lack of weighing scales in the community, and sometimes in the health facilities. Methods This was a hospital-based cross-sectional study. Two midwives weighed 706 newborns and measured their foot length, head, chest, thigh and mid-upper arm circumferences within 24 hours after birth. Data was analysed using STATA version 10.0. Correlation with birth weight using Pearson’s correlation coefficient and Receiver Operating Characteristics curve analysis were done to determine the measure that best predicts birth weight. Sensitivity and specificity were calculated for a range of measures to obtain operational cut-off points; and Likelihood Ratios and Diagnostic Odds Ratio were determined for each cut-off point. Results Birth weights ranged from 1370–5350 grams with a mean of 3050 grams (SD 0.53) and 85 (12%) babies weighed less than 2500 grams. All anthropometric measurements had a positive correlation with birth weight, with foot length showing the strongest (r = 0.76) and thigh circumference the weakest (r = 0.62) correlations. Foot length had the highest predictive value for low birth weight (AUC = 0.97) followed by mid-upper arm circumference (AUC = 0.94). Foot length and chest circumference had the highest sensitivity (94%) and specificity (90%) respectively for screening low birth weight babies at the selected cut-off points. Chest circumference had a significantly higher positive likelihood ratio (8.7) than any other measure, and foot length had the lowest negative likelihood ratio. Chest circumference and foot length had diagnostic odds ratios of 97% and 77% respectively. Foot length was easier to measure and it involved minimal exposure of the baby to cold. A cut-off of foot length 7.9 cm had sensitivity of 94% and specificity of 83% for predicting low birth weight. Conclusions This study suggests foot length as the most appropriate predictor for low birth weight in comparison to chest, head, mid-upper arm and thigh circumference in the Uganda setting. Use of low cost and easy to use tools to identify low birth weight babies by village health teams could support community efforts to save newborns. PMID:23587297
The physiotherapeutic context of loss of dominant arm function due to occupational accidents.
Kostiukow, Anna; Kaluga, Elżbieta; Samborski, Włodzimierz; Rostkowska, Elżbieta
2016-12-23
The study examines the problem of dominant arm function loss in rural adult patients due to work-related accidents. The types of risks involved in farmyard work include falling from a height, manually moving loads, overturning/accident whilst driving an agricultural tractor, noise and vibration, use of pesticides, and the risk of being cut or injured. The study focuses on adaptation of the non-dominant arm. The main aim of the study was evaluation of visual-motor coordination on the basis of performance of the non-dominant hand in patients after the loss of function of the dominant arm. The research sample consisted of 52 patients with a permanent or temporary loss of function or severely limited function of the dominant arm. The subjects were patients with arm amputations due to various occupational injuries sustained while operating agricultural and construction machinery and forestry equipment, following traumas or complicated medical surgeries of the arm, or due to car accidents. The following tests were applied in the analysis: I) Dufour cross-shaped apparatus test for assessing visual motor-coordination; II) paper-and-pencil tests and the Relay Baton motor fitness test; III) anthropometric measurements; IV) Edinburgh Handedness Inventory; and V) a questionnaire survey. The results of the apparatus and motor tests indicate the same tendency: reaction to stimuli measured on the basis of performance of the non-dominant arm is longer in shorter and older patients. Visual-motor coordination, as measured by the performance of the non-dominant arm, is significantly affected by the subject's body height and arm length.
Code of Federal Regulations, 2014 CFR
2014-01-01
... internal risk rating and segmentation system; risk parameter quantification system; data management and... advanced IRB systems, operational risk management processes, operational risk data and assessment systems... generated on an arm's-length basis between the seller and the obligor (intercompany accounts receivable and...
Marnitz, Simone; Martus, Peter; Köhler, Christhardt; Stromberger, Carmen; Asse, Elke; Mallmann, Peter; Schmidberger, Heinz; Affonso Júnior, Renato José; Nunes, João Soares; Sehouli, Jalid; Budach, Volker
2016-02-01
The Uterus-11 trial was designed to evaluate the role of surgical staging in patients with cervical cancer before primary chemoradiation therapy (CRT). The present report provides the toxicity data stratified by the treatment arm and technique. A total of 255 patients with carcinoma of the uterine cervix (International Federation of Gynecology and Obstetrics stage IIB-IVA) were randomized to either surgical staging followed by CRT (arm A) or clinical staging followed by CRT (arm B). Patients with para-aortic metastases underwent extended field radiation therapy (RT). Brachytherapy was mandatory. The present report presents the acute therapy-related toxicities stratified by treatment arm and radiation technique. A total of 240 patients were eligible (n=121 in arm A; n=119 in arm B). Of the 240 patients, 236 (98.3%) underwent external beam RT with a median total dose of 50.4 Gy. The mean treatment duration was 53 days. Of the patients, 60% underwent intensity modulated RT (IMRT). A total of 234 patients (97.5%) underwent chemotherapy, and 231 (96.3%) underwent brachytherapy, with a median single dose of 6 Gy covering the tumor to a median nominal total dose of 28 Gy. Treatment was well tolerated, with 0% grade ≥3 genitourinary and gastrointestinal toxicity, 6% grade 3 nausea, 3% grade 3 vomiting, and <2% grade 3 diarrhea. More patients after surgical staging experienced grade 2 anemia (54.3% in arm A vs 45.3% in arm B; P=.074) and grade 2 leukocytopenia (41.4% vs 31.6%; P=.56). Of the patients who received IMRT versus a 3-dimensional technique, 65.3% versus 33.7% presented with grade 2 anemia. Grade 3 gastrointestinal and grade 2 bladder toxicity were significantly reduced with the use of IMRT. The incidence and severity of acute therapy-related toxicity compared favorably with those from other randomized trials. Excellent adherence to treatment and treatment quality was achieved compared with patterns of care analyses. Surgical staging led to a doubled number of patients treated with extended field RT. The question of whether surgical staging is beneficial in the context of primary CRT requires further study. Copyright © 2016 Elsevier Inc. All rights reserved.
Zhang, Xiaochen; Brown, Justin C; Paskett, Electra D; Zemel, Babette S; Cheville, Andrea L; Schmitz, Kathryn H
2017-07-01
Studies in breast cancer-related lymphedema (BRCL) have exclusively examined total arm volume, but not the specific tissue composition that contributes to total volume. We evaluated baseline differences in arm tissue composition [fat mass, lean mass, bone mineral content (BMC), and bone mineral density (BMD)] between the affected and unaffected arms in women with BRCL. We compared changes in arm tissue composition and self-reported lymphedema symptoms after 1 year of weight-lifting versus control. We utilized data from physical activity and lymphedema trial that included 141 women with BRCL. Arm tissue composition was quantified using dual-energy X-ray absorptiometry. The severity of lymphedema was quantified using self-report survey. Weight-lifting was performed at community fitness facilities. At baseline, the affected arm had more fat (∆ = 89.7 g; P < 0.001) and lean mass (∆ = 149.1 g; P < 0.001), but less BMC (∆ = -3.2 g; P < 0.001) and less BMD (∆ = -5.5 mg/cm 2 ; P = 0.04) than the unaffected arm. After 12 months of weight-lifting, composition of the affected arm was improved: lean mass (71.2 g; P = 0.01) and BMD (14.0 mg/cm 2 ; P = 0.02) increased, arm fat percentage decreased (-1.5%; P = 0.003). Composition of the unaffected arm was only improved in lean mass (65.2 g; P = 0·04). Increases in lean mass were associated with less severe BCRL symptoms. Among women with BRCL, slowly progressive weight-lifting could improve arm tissue composition. Changes in arm tissue composition predict changes in symptom burden. Investigating the combined effects of exercise and weight loss on arm tissue composition and BCRL symptoms may provide additional insight into the benefits of lifestyle modification on lymphedema biology.
Portnoy, Sigal; Hersch, Ayelet; Sofer, Tal; Tresser, Sarit
2017-06-01
To test whether paired-play will induce longer path length and ranges of movement of the center of pressure (COP), which reflects on balance performance and stability, compared to solo-play and to test the difference in the path length and ranges of movement of the COP while playing the virtual reality (VR) game with the dominant hand compared to playing it with the nondominant hand. In this cross-sectional study 20 children (age 6.1 ± 0.7 years old) played an arm movement controlled VR game alone and with a peer while each of them stood on a pressure measuring pad to track the path length and ranges of movement of the COP. The total COP path was significantly higher during the paired-play (median 295.8 cm) compared to the COP path during the solo-play (median 189.2 cm). No significant differences were found in the reaction time and the mediolateral and anterior-posterior COP ranges between solo-play and paired-play. No significant differences were found between the parameters extracted during paired-play with the dominant or nondominant hand. Our findings imply that the paired-play is advantageous compared to solo-play since it induces a greater movement for the child, during which, higher COP velocities are reached that may contribute to improving the balance control of the child. Apart from the positive social benefits of paired-play, this positive effect on the COP path length is a noteworthy added value in the clinical setting when treating children with balance disorder.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lewis, G.N.; Ride, S.K.; Townsend, J.S.
It is widely believed that an arms control limit on nuclear-armed sea-launched cruise missiles would be nearly impossible to verify. Among the reasons usually given are: these weapons are small, built in nondistinctive industrial facilities, deployed on a variety of ships and submarines, and difficult to distinguish from their conventionally armed counterparts. In this article, it is argued that the covert production and deployment of nuclear-armed sea-launched cruise missiles would not be so straightforward. A specific arms control proposed is described, namely a total ban on nuclear-armed sea-launched cruise missiles. This proposal is used to illustrate how an effective verificationmore » scheme might be constructed. 9 refs., 6 figs.« less
Dispelling myths about verification of sea-launched cruise missiles.
Lewis, G N; Ride, S K; Townsend, J S
1989-11-10
It is widely believed that an arms control limit on nuclear-armed sea-launched cruise missiles would be nearly impossible to verify. Among the reasons usually given are: these weapons are small, built in nondistinctive industrial facilities, deployed on a variety of ships and submarines, and difficult to distinguish from their conventionally armed counterparts. In this article, it is argued that the covert production and deployment of nuclear-armed sealaunched cruise missiles would not be so straightforward. A specific arms control proposal is described, namely a total ban on nuclear-armed sea-launched cruise missiles. This proposal is used to illustrate how an effective verification scheme might be constructed.
Zhang, Yingshi; Cai, Jiayi; Zhang, Yaqiong; Ren, Tianshu; Zhao, Mingyi; Zhao, Qingchun
2016-01-01
To conduct a meta-analysis of clinical trials that examined the effect of music-supported therapy on stroke-induced motor dysfunction, comprehensive literature searches of PubMed, Embase and the Cochrane Library from their inception to April 2016 were performed. A total of 10 studies (13 analyses, 358 subjects) were included; all had acceptable quality according to PEDro scale score. The baseline differences between the two groups were confirmed to be comparable. Compared with the control group, the standardized mean difference of 9-Hole Peg Test was 0.28 (−0.01, 0.57), 0.64 (0.31, 0.97) in Box and Block Test, 0.47 (0.08, 0.87) in Arm Paresis Score and 0.35 (−0.04, 0.75) in Action Research Arm Test for upper-limb motor function, 0.11 (−0.24, 0.46) in Berg Balance Scale score, 0.09 (−0.36, 0.54) in Fugl-Meyer Assessment score, 0.30 (−0.15, 0.74) in Wolf Motor Function Test, 0.30 (−0.15, 0.74) in Wolf Motor Function time, 0.65 (0.14, 1.16) in Stride length and 0.62 (0.01, 1.24) in Gait Velocity for total motor function, and 1.75 (0.94, 2.56) in Frontal Assessment Battery score for executive function. There was evidence of a positive effect of music-supported therapy, supporting its use for the treatment of stroke-induced motor dysfunction. This study was registered at PRESPERO (CRD42016037106). PMID:27917945
Do South Indian newborn babies have higher fat percentage for a given birth weight?
Kv, Radha Krishna; Hemalatha, Rajkumar; Mamidi, Raja Sriswan; Jj, Babu Geddam; Balakrishna, N
2016-05-01
India is experiencing rapidly escalating epidemics of diabetes and cardiovascular disease. High fat percent in Indian adults may have its origins at birth (Fetal origin hypothesis). Conflicting evidence from India have shown increased or similar fat mass in Indian newborn babies compared to western countries. To compare body composition of term infants with data from similar studies in India and developed countries. Cross-sectional study in newborn infants at the antenatal ward of a tertiary care hospital in South India. 626 mothers and their newborn babies. Maternal body weight and height, baby weight, length, head circumference, skin folds at three sites. Body fat, arm muscle area and arm muscle index were calculated based on known methods. Mean (SD) birth weight of newborn babies was 2.80 (0.37) kg and 43% of them were small for gestational age. Birth weight was significantly related to subscapular (r=0.445; p<0.001) and triceps (r=0.567; p<0.001) skin fold thickness. Mean (CI) Subscapular skin fold thickness and total body fat % was 3.81mm (3.74-3.97) and 10.5% (10.2-10.8). Mean total body fat % for small for gestational age (SGA) (9.57%) was significantly lower than appropriate for gestational age (AGA) babies (11.7%). The mean body fat percent in AGA infants was similar to that of studies reported on term infants of developed countries, suggesting that South Indian babies may accumulate similar fat mass with increasing birth weight and gestational age. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Method and apparatus for hybrid position/force control of multi-arm cooperating robots
NASA Technical Reports Server (NTRS)
Hayati, Samad A. (Inventor)
1989-01-01
Two or more robotic arms having end effectors rigidly attached to an object to be moved are disclosed. A hybrid position/force control system is provided for driving each of the robotic arms. The object to be moved is represented as having a total mass that consists of the actual mass of the object to be moved plus the mass of the moveable arms that are rigidly attached to the moveable object. The arms are driven in a positive way by the hybrid control system to assure that each arm shares in the position/force applied to the object. The burden of actuation is shared by each arm in a non-conflicting way as the arm independently control the position of, and force upon, a designated point on the object.
Tajadura-Jiménez, Ana; Tsakiris, Manos; Marquardt, Torsten; Bianchi-Berthouze, Nadia
2015-01-01
Auditory feedback accompanies almost all our actions, but its contribution to body-representation is understudied. Recently it has been shown that the auditory distance of action sounds recalibrates perceived tactile distances on one’s arm, suggesting that action sounds can change the mental representation of arm length. However, the question remains open of what factors play a role in this recalibration. In this study we investigate two of these factors, kinaesthesia, and sense of agency. Across two experiments, we asked participants to tap with their arm on a surface while extending their arm. We manipulated the tapping sounds to originate at double the distance to the tapping locations, as well as their synchrony to the action, which is known to affect feelings of agency over the sounds. Kinaesthetic cues were manipulated by having additional conditions in which participants did not displace their arm but kept tapping either close (Experiment 1) or far (Experiment 2) from their body torso. Results show that both the feelings of agency over the action sounds and kinaesthetic cues signaling arm displacement when displacement of the sound source occurs are necessary to observe changes in perceived tactile distance on the arm. In particular, these cues resulted in the perceived tactile distances on the arm being felt smaller, as compared to distances on a reference location. Moreover, our results provide the first evidence of consciously perceived changes in arm-representation evoked by action sounds and suggest that the observed changes in perceived tactile distance relate to experienced arm elongation. We discuss the observed effects in the context of forward internal models of sensorimotor integration. Our results add to these models by showing that predictions related to action sounds must fit with kinaesthetic cues in order for auditory inputs to change body-representation. PMID:26074843
Uribe, Alberto A; Mendel, Ehud; Peters, Zoe A; Shneker, Bassel F; Abdel-Rasoul, Mahmoud; Bergese, Sergio D
2017-10-01
To determine the comparison of its clinical utility and safety profile for visual evoked potential (VEP) monitoring during prone spine surgeries under total intravenous anesthesia (TIVA) versus balanced general anesthesia using the SightSaver™ visual stimulator. The protocol was designed asa pilot, single center, prospective, randomized, and double-arm study. Subjects were randomized to receive either TIVA or balanced general anesthesia. Following induction and intubation, 8 electrodes were placed subcutaneously to collect VEP recordings. The SightSaver™ visual stimulator was placed on the subject's scalp before prone positioning. VEP waveforms were recorded every 30min and assessed by a neurophysiologist throughout the length of surgery. A total of 19 subjects were evaluated and VEP waveforms were successfully collected. TIVA group showed higher amplitude and lower latency than balanced anesthesia. Our data suggested that TIVA is associated with higher VEP amplitude and shorter latencies than balanced general anesthesia; therefore, TIVA could be the most efficient anesthesia regimen for VEP monitoring. The findings help to better understand the effect of different anesthesia regimens on intra-operative VEP monitoring. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
1978-01-01
During eye surgery, the surgeon uses an illuminating instrument called an opthalmoscope for close examination of the retina or the interior of the eye. Ordinarily, electric power for the head-mounted light is supplied through a cord from an overhead swivel arm or a floor pedestal. Within limits of cord length and swivel arm movement, the surgeon has considerable freedom of motion. But when more than one opthalmoscope is involved, tangling and interference of the power cords becomes a problem. St. Luke's Hospital, Cleveland, Ohio asked Lewis Research Center for assistance in finding a solution. Lewis responded with a battery-powered system that totally frees the surgeon of attached cords and swivels. Borrowing from space technology, Lewis used small, lightweight nickel-cadmium batteries that can deliver high intensity light for an hour and can be recharged overnight. The Opthalmoscope Powerpack consists of eight batteries in three containers affixed to a webbed belt, and a novel on-off switch equipped with a spring-loaded plexiglass 'flapper.' The belt pack is worn underneath the surgical gown and the flapper permits the doctor to activate the switch by elbow pressure. Lewis built five units and they have been in service at St. Luke's Hospital for a year. Used for routine examinations as well as for surgery, they have demonstrated excellent reliability.
Immunocytological analysis of meiotic recombination in two anole lizards (Squamata, Dactyloidae).
Lisachov, Artem P; Trifonov, Vladimir A; Giovannotti, Massimo; Ferguson-Smith, Malcolm A; Borodin, Pavel M
2017-01-01
Although the evolutionary importance of meiotic recombination is not disputed, the significance of interspecies differences in the recombination rates and recombination landscapes remains under-appreciated. Recombination rates and distribution of chiasmata have been examined cytologically in many mammalian species, whereas data on other vertebrates are scarce. Immunolocalization of the protein of the synaptonemal complex (SYCP3), centromere proteins and the mismatch-repair protein MLH1 was used, which is associated with the most common type of recombination nodules, to analyze the pattern of meiotic recombination in the male of two species of iguanian lizards, Anolis carolinensis Voigt, 1832 and Deiroptyx coelestinus (Cope, 1862). These species are separated by a relatively long evolutionary history although they retain the ancestral iguanian karyotype. In both species similar and extremely uneven distributions of MLH1 foci along the macrochromosome bivalents were detected: approximately 90% of crossovers were located at the distal 20% of the chromosome arm length. Almost total suppression of recombination in the intermediate and proximal regions of the chromosome arms contradicts the hypothesis that "homogenous recombination" is responsible for the low variation in GC content across the anole genome. It also leads to strong linkage disequilibrium between the genes located in these regions, which may benefit conservation of co-adaptive gene arrays responsible for the ecological adaptations of the anoles.
Thrust Stand for Electric Propulsion Performance Evaluation
NASA Technical Reports Server (NTRS)
Markusic, T. E.; Jones, J. E.; Cox, M. D.
2004-01-01
An electric propulsion thrust stand capable of supporting thrusters with total mass of up to 125 kg and 1 mN to 1 N thrust levels has been developed and tested. The mechanical design features a conventional hanging pendulum arm attached to a balance mechanism that transforms horizontal motion into amplified vertical motion, with accommodation for variable displacement sensitivity. Unlike conventional hanging pendulum thrust stands, the deflection is independent of the length of the pendulum arm, and no reference structure is required at the end of the pendulum. Displacement is measured using a non-contact, optical linear gap displacement transducer. Mechanical oscillations are attenuated using a passive, eddy current damper. An on-board microprocessor-based level control system, which includes a two axis accelerometer and two linear-displacement stepper motors, continuously maintains the level of the balance mechanism - counteracting mechanical %era drift during thruster testing. A thermal control system, which includes heat exchange panels, thermocouples, and a programmable recirculating water chiller, continuously adjusts to varying thermal loads to maintain the balance mechanism temperature, to counteract thermal drifts. An in-situ calibration rig allows for steady state calibration both prior to and during thruster testing. Thrust measurements were carried out on a well-characterized 1 kW Hall thruster; the thrust stand was shown to produce repeatable results consistent with previously published performance data.
NASA Technical Reports Server (NTRS)
1978-01-01
During eye surgery, the surgeon uses an illuminating instrument called an opthalmoscope for close examination of the retina or the interior of the eye. Ordinarily, electric power for the head-mounted light is supplied through a cord from an overhead swivel arm or a floor pedestal. Within limits of cord length and swivel arm movement, the surgeon has considerable freedom of motion. But when more than one opthalmoscope is involved, tangling and interference of the power cords becomes a problem. St. Luke's Hospital, Cleveland, Ohio asked Lewis Research Center for assistance in finding a solution. Lewis responded with a battery-powered system that totally frees the surgeon of attached cords and swivels. Borrowing from space technology, Lewis used small, lightweight nickel-cadmium batteries that can deliver high intensity light for an hour and can be recharged overnight. The Opthalmoscope Powerpack consists of eight batteries in three containers affixed to a webbed belt, and a novel on-off switch equipped with a springloaded plexiglass "flapper." The belt pack is worn underneath the surgical gown and the flapper permits the doctor to activate the switch by elbow pressure. Lewis built five units and they have been in service at St. Luke's Hospital for a year. Used for routine examinations as well as for surgery, they have demonstrated excellent reliability.
Gallagher, Lisa M; Gardner, Vickie; Bates, Debbie; Mason, Shelley; Nemecek, Jeanine; DiFiore, Jacquelyn Baker; Bena, James; Li, Manshi; Bethoux, Francois
Music therapy (MT) research has demonstrated positive effects on fatigue, depressed mood, anxiety, and pain in perioperative care areas. However, there has been limited research on the effects of MT for surgical patients on orthopaedic units. The purpose of this study was to understand the impact of MT sessions on post-elective orthopaedic surgery patients' pain, mood, nausea, anxiety, use of narcotics and antiemetics, and length of stay. This was a randomized controlled study with an experimental arm (MT sessions) and a control arm (standard medical care). Patients received MT within 24 hours of admission to the unit, as well as every day of their stay. Same-day pre- and postdata were collected 30 minutes apart for both arms, including patient self-reported mood, pain, anxiety, and nausea. Use of medications and length of stay were gleaned from the electronic medical record. Data were obtained for 163 patients, age 60.5 ± 11.1 years, 56% of whom were male. Joints targeted by surgeries were hips (54%), knees (42%), and shoulders (4%). There were significantly greater changes favoring the MT group on Day 1 (pain, anxiety, and mood), Day 2 (pain, anxiety, mood, and nausea), and Day 3 (pain, anxiety, and mood). Among participants with a pre-pain score of 2 or more on Day 1, a decrease of at least 2 points was noted in 36% of the MT group and 10% of the control group (P < .001). Overall, 73% of MT patients versus 41% of control patients reported improved pain (P < .001). No significant between-group differences in medications or length of stay were noted. We observed greater same-day improvements of pain, emotional status, and nausea with MT sessions, compared to usual care, in patients hospitalized after elective orthopaedic surgeries. Effects on narcotic and antiemetic usage, as well as length of stay, were not observed. More research needs to be conducted to better understand the benefits of MT pre- and post-elective orthopaedic surgery.
Krasniqi, Ermira; Koni, Mynyr; Kabashi, Antigona; Bahtiri, Abedin; Gjeli, Selda; Boshnjaku, Arben
2016-10-01
This observational, cross-sectional study, investigates and compares the differences of BMD, T-score, Z-score and isometric strength between dominant (D) versus non-dominant (ND) arms of 162 subjects aged 40-65 in a developing, low income country (Kosova). Bone Mineral Density (BMD), T-score and Z-score at distal forearm regions of both arms (measured by DXA scan), together with the Handgrip Isometric Strength (HIS) (by handgrip) were evaluated in a total subjects (53 Males and 109 Females). Additionally, General Healthcare Status Questionnaire together with self-administrated International Physical Activity Questionnaire (IPAQ) were filled. Significant differences (p<0.05) between arms were found in BMD, T-score, and Z-score in total subjects and in females, whereas not significant differences (p>0.05) were observed in Males BMD comparing to significantly higher results (p<0.05) in T-score and Z-score. Significant differences (p<0.05) were also found in total subjects and in females handgrip, but not (p>0.05) in males. When comparing the total subject's BMD, T-score, Z-score and Handgrip based on the PA levels (1 to 3 according to IPAQ scoring) no significant differences (p>0.05) were found between PA1, as well as PA3 whereas significantly differences (p<0.05) were found in D arms of PA2 level. The study analyses side-to-side differences in bone density and muscular force between D and ND arms amongst a population which is frequently exposed to diagnostic screenings for age related osteomuscular conditions (aged 40-60), and demonstrates that these differences should be in consideration amongst clinicians, but not in the way it is done right now.
Bilimoria, Karl Y; Chung, Jeanette W; Hedges, Larry V; Dahlke, Allison R; Love, Remi; Cohen, Mark E; Tarpley, John; Mellinger, John; Mahvi, David M; Kelz, Rachel R; Ko, Clifford Y; Hoyt, David B; Lewis, Frank H
2016-03-01
Debate continues regarding whether to further restrict resident duty hour policies, but little high-level evidence is available to guide policy changes. To inform decision making regarding duty hour policies, the Flexibility in Duty Hour Requirements for Surgical Trainees (FIRST) Trial is being conducted to evaluate whether changing resident duty hour policies to permit greater flexibility in work hours affects patient postoperative outcomes, resident education, and resident well-being. Pragmatic noninferiority cluster-randomized trial of general surgery residency programs with 2 study arms. Participating in the study are Accreditation Council for Graduate Medical Education (ACGME)-approved US general surgery residency programs (n = 118), their affiliated hospitals (n = 154), surgical residents and program directors, and general surgery patients from July 1, 2014, to June 30, 2015, with additional patient safety outcomes collected through June 30, 2016. The data collection platform for patient outcomes is the American College of Surgeons National Surgical Quality Improvement Program (ACS NSQIP), thus only hospitals participating in the ACS NSQIP were included. In the usual care arm, programs adhered to current ACGME resident duty hour standards. In the intervention arm, programs were allowed to deviate from current standards regarding maximum shift lengths and minimum time off between shifts through an ACGME waiver. Death or serious morbidity within 30 days of surgery measured through ACS NSQIP, as well as resident satisfaction and well-being measured through a survey delivered at the time of the 2015 American Board of Surgery in Training Examination (ABSITE). A total of 118 general surgery residency programs and 154 hospitals were enrolled in the FIRST Trial and randomized. Fifty-nine programs (73 hospitals) were randomized to the usual care arm and 59 programs (81 hospitals) were randomized to the intervention arm. Intent-to-treat analysis will be used to estimate the effectiveness of assignment to the intervention arm on patient outcomes, resident education, and resident well-being compared with the usual care arm. Several sensitivity analyses will be performed to determine whether there were differential effects when examining only inpatients, high-risk patients, and emergent/urgent cases. To our knowledge, the FIRST Trial is the first national randomized clinical trial of duty hour policies. Results of this study may be informative to policymakers and other stakeholders engaged in restructuring graduate medical training to enhance the quality of patient care and resident education. clinicaltrials.org Identifier: NCT02050789.
Navarro, José Francisco; Maldonado, Enrique
2002-10-01
3,4-Methylenedioxymethamphetamine (MDMA) is a compound structurally similar to methamphetamine, which has become one of the most widely used illicit substances. Animal studies investigating acute effects of MDMA on anxiety are unclear since, although an anxiogenic-like action of MDMA in different animal models of anxiety has been mainly described, there is also evidence supporting an anxiolytic-like effect for this drug. An attempt was made to clarify the possible anxiogenic-like profile of MDMA (1, 8 and 15 mg/kg i.p.) by analyzing its effect on behavior of male mice in the elevated plus-maze test. Moreover, the possible development of tolerance to the effects of MDMA on anxiety after its subchronic administration for 5 consecutive days was examined. The parameters evaluated included: (1) total time in open arms, (2) total time in closed arms, (3) total time in central area, (4) number of open arm entries, (5) number of closed arm entries and (6) number of central area entries. Acute treatment with MDMA (8 mg/kg) significantly reduced the time spent in the open arms, as well as markedly increasing the number of entries in the closed arms and in the central area, as compared with the control group, suggesting that MDMA, at this dose, has an anxiogenic-like activity. Mice subchronically treated with the drug (1 and 8 mg/kg) displayed a notable reduction in the time spent in the open arms, accompanied by an increase in the time spent in the closed arms and in the central platform. These results indicate that the anxiogenic-like effect found after acute treatment is not only maintained but also more marked after subchronic treatment. In contrast, mice treated subchronically with the highest dose of MDMA (15 mg/kg) exhibited a significant increase in the time spent in the open arms as well as a marked reduction in the time spent in the closed arms, supporting an anxiolytic-like activity of the drug. A possible dual pharmacological property of MDMA on anxiety is suggested.
Colloidal ZnO and Zn(1-x)Co(x)O tetrapod nanocrystals with tunable arm lengths.
Hodges, James M; Fenton, Julie L; Gray, Jennifer L; Schaak, Raymond E
2015-10-28
Tetrapod-shaped ZnO nanocrystals exhibit exceptional optoelectronic properties, including intense ultraviolet photoluminescence emission, that make them attractive for applications that include lasers, sensors, and photocatalysts. However, synthetic methods that produce ZnO tetrapods typically include high-temperature vapor-deposition approaches that do not readily achieve characteristic dimensions of less than 100 nm or colloidal methods that require added metal dopants, which modify the inherent properties of ZnO. Here, we report a robust, modified solution-phase synthetic protocol for generating colloidal ZnO tetrapods that does not require the use of metal dopants. The ZnO tetrapod arm lengths can be tuned from 10 to 25 nm by adjusting the amount of Zn reagent used in the reaction. Subsequent seeded-growth produced even larger colloidal ZnO tetrapods with 62 nm arms. Photoluminescence (PL) measurements confirm that the tetrapods are of high crystalline quality, and the ultraviolet PL emission wavelengths that are observed fall between those of previously reported metal-doped colloidal ZnO tetrapods, which exhibit dopant-induced red- or blue-shifts. Furthermore, the reaction strategy can be modified to produce cobalt-substituted ZnO, offering a chemical pathway to tetrapod-shaped Zn1-xCoxO nanocrystals.
Nakamatsu, Kiyoshi; Nishimura, Yasumasa; Kanamori, Shuichi; Koike, Ryuta; Tachibana, Izumi; Nishikawa, Tatsuyuki; Shibata, Toru
2011-07-01
Postoperative adjuvant treatment with strontium-90 radiation therapy (RT) is a proven technique for reducing the recurrence of pterygium. This randomized trial was conducted to evaluate whether a total dose of 40 Gy provides a better local control rate than a total dose of 30 Gy for surgically resected pterygia. A single institutional randomized trial was conducted. Between 1999 and 2003, 74 pterygia in 71 patients were randomly allocated to 30 Gy/3 fractions/15 days (arm A) or to 40 Gy/4 fractions/22 days (arm B). Only primary pterygia for which RT could be started within 3 days of surgical resection were included. Postoperative RT was given by a strontium-90 eye applicator, and a dose of 10 Gy per fraction was delivered in weekly fractions (day 1, 8, 15, 22). Of the 74 pterygia treated, 73 in 70 patients were analyzed. Of the 73 pterygia, 41 were allocated to arm A, and the remaining 32 to arm B. The 2-year local control rates for arm A and arm B were 85% and 75%, respectively, without significant difference. No serious acute and late complications were noted in either arm. Our new standard fractionation for postoperative RT for pterygia is 30 Gy/3 fractions.
Jang, Bora; Kim, Boyoung; Kim, Hyunsook; Kwon, Hyokyoung; Kim, Minjeong; Seo, Yunmi; Colas, Marion; Jeong, Hansaem; Jeong, Eun Hye; Lee, Kyuri; Lee, Hyukjin
2018-06-08
Enzymatic synthesis of RNA nanostructures is achieved by isothermal rolling circle transcription (RCT). Each arm of RNA nanostructures provides a functional role of Dicer substrate RNA inducing sequence specific RNA interference (RNAi). Three different RNAi sequences (GFP, RFP, and BFP) are incorporated within the three-arm junction RNA nanostructures (Y-RNA). The template and helper DNA strands are designed for the large-scale in vitro synthesis of RNA strands to prepare self-assembled Y-RNA. Interestingly, Dicer processing of Y-RNA is highly influenced by its physical structure and different gene silencing activity is achieved depending on its arm length and overhang. In addition, enzymatic synthesis allows the preparation of various Y-RNA structures using a single DNA template offering on demand regulation of multiple target genes.
Starbursts and Wispy Drops : Surfactants Spreading on Gel Substrates
NASA Astrophysics Data System (ADS)
Mukhopadhyay, Shomeek; Daniels, Karen; Behringer, Robert
2005-11-01
We report a phase diagram for a novel instability seen in drops of nonionic surfactant solution (Triton X-305) spreading on viscoelastic agar gel substrate . This system allows us to examine the effect of varying the effective fluidity/stiffness of aqueous substrates. The morphology is strongly affected by the substrate fluidity, ranging from spreading starbursts of arms on weak gels, to wispy drops on intermediate strength gels, to circular drops on stiff gels. We analyze the dynamics of spreading in the starburst phase, where the arm length grows as t ^3/4 at early times, independent of the gel strength and surfactant concentration. The number of arms is proportional to the surfactant concentration and inversely proportional to the gel strength. Ongoing work is exploring the effects of changing the drop volume.
NASA Astrophysics Data System (ADS)
Chen, Xilun; Wang, Xiangchuan; Pan, Shilong
2017-03-01
An implementation of a distance measurement system using double-sideband with suppressed carrier modulation (DSB-SC) frequency scanning interferometry is proposed to reduce the variations in the optical path and improve the measurement accuracy. In this proposed system, the electro-optic DSB-SC is used to create dual-swept signals with opposite scanning directions. For each swept signal, the relative distance between the reference arm and the measuring arm is determined by the beat frequency of signals from two arms. By multiplying both beat signals, measurement errors caused by variations in the optical path can be greatly reduced. As an experimental demonstration, a vibration was introduced in the optical path length. The experimental results show that the variations can be suppressed for over 19.9 dB.
Nemeth, Julianna M; Cooper, Sarah; Wermert, Amy; Shoben, Abigail; Wewers, Mary Ellen
2017-12-01
Quitlines are successful tools for smoking cessation, but no known study has examined whether type of phone service (cell phone only (CPO) vs. landline (LL)) impacts quitline utilization, quit attempts, and sustained cessation. This report details an observational study examining the association between phone service and quitline utilization and cessation among Ohio Appalachian adults willing to quit smoking and enrolled in a cessation trial from 2010 to 2014. A secondary analysis was conducted with data obtained from smokers enrolled in the Ohio Tobacco Quitline arm of a group randomized trial (n = 345). The intermediate outcome variables included number of calls, cumulative total call length, average call length, verified shipments of NRT, and 24-hour quit attempt. The primary outcome measure was biologically confirmed 7-day point prevalence abstinence from tobacco at 3, 6, and 12 months post treatment. Participants with LL service, on average, made almost one more call to the quitline and spoke 17.2 min longer over the course of treatment than those with CPO service. Those with LL service were more likely to receive a second 4-week supply of NRT. Phone service status was not associated with average quitline call length, receiving at least one NRT shipment, having made one quit attempt at the end of treatment, or biochemically confirmed abstinence at 3, 6, or 12-month follow-up. Participants with LL services completed more counseling calls, accrued a longer cumulative length, and received more NRT when compared with CPO service participants. However, type of phone service did not deter abstinence outcomes.
Porras, Ileana C; Hiscock, Merrill; Layne, Charles S
2015-12-01
Previous studies have shown that men can balance a dowel rod on the index finger for a longer time than women can. The factors that account for the difference are unknown, but the difference may be attributable either to a difference in whole-body agility or a difference in the use of visual cues. Three experiments involving a total of 62 adult women with a mean age of 21.2 yr. (SD=3.8) and 62 adult men with a mean age of 21.9 yr. (SD=6.6) tested these potential explanations. Experiment 1 replicated the sex difference and assessed the relevance of whole-body agility by comparing standing and seated conditions. Experiments 2 and 3 explored the role of rod length and visual fixation point, respectively. Each experiment yielded a significant sex difference, but the difference was not affected by the participant's posture, the length of the rod, or the fixation point. Possible alternative explanations for the difference include differences in (1) the speed of processing degree of visual tilt; (2) arm mass, which affects the inertia of the balancing system; and (3) experience in open-skill sports.
Hooper, Justin B; Bedrov, Dmitry; Smith, Grant D
2009-03-28
The effect of polymer architecture on the aggregation behavior of C60 fullerenes tethered with a single chain of poly(ethylene oxide) (PEO) in aqueous solution has been investigated using coarse-grained, implicit solvent molecular dynamics simulations. The PEO-grafted fullerenes were comprised of a single tether of 60 repeat units represented as a linear polymer, a three-arm star (20 repeat units/arm) or a six-arm star (10 repeat units/arm). Additionally, the influence of arm length on self-assembly of the PEO-fullerene conjugates was investigated for the three-arm stars. Self-assembly is driven by favorable fullerene-fullerene and fullerene-PEO interactions. Our simulations reveal that it should be possible to control the size and geometry of the self-assembled fullerene aggregates in water through variation of PEO architecture and PEO molecular weight. We found that aggregate size and shape could be understood qualitatively in terms of the packing parameter concept that has been employed for diblock polymer and surfactant self-assembly. Higher molecular weight PEO (longer arms) and more compact PEO (more arms for the same molecular weight) resulted in greater steric repulsion between fullerenes, engendering greater aggregate surface curvature and hence the formation of smaller, more spherically shaped aggregates. Finally, weak attractive interactions between PEO and the fullerenes were found to play an important role in determining aggregate shape, size and the dynamics of self-assembly.
NASA Astrophysics Data System (ADS)
Yamauchi, Toyohiko; Yamada, Hidenao; Matsui, Hisayuki; Yasuhiko, Osamu; Ueda, Yukio
2018-02-01
We developed a compact Mach-Zehnder interferometer module to be used as a replacement of the objective lens in a conventional inverted microscope (Nikon, TS100-F) in order to make them quantitative phase microscopes. The module has a 90-degree-flipped U-shape; the dimensions of the module are 160 mm by 120 mm by 40 mm and the weight is 380 grams. The Mach-Zehnder interferometer equipped with the separate reference and sample arms was implemented in this U-shaped housing and the path-length difference between the two arms was manually adjustable. The sample under test was put on the stage of the microscope and a sample light went through it. Both arms had identical achromatic lenses for image formation and the lateral positions of them were also manually adjustable. Therefore, temporally and spatially low coherent illumination was applicable because the users were able to balance precisely the path length of the two arms and to overlap the two wavefronts. In the experiment, spectrally filtered LED light for illumination (wavelength = 633 nm and bandwidth = 3 nm) was input to the interferometer module via a 50 micrometer core optical fiber. We have successfully captured full-field interference images by a camera put on the trinocular tube of the microscope and constructed quantitative phase images of the cultured cells by means of the quarter-wavelength phase shifting algorithm. The resultant quantitative phase images were speckle-free and halo-free due to spectrally and spatially low coherent illumination.
NASA Astrophysics Data System (ADS)
Seaman, Shane T.; Cook, Anthony L.; Scola, Salvatore J.; Hostetler, Chris A.; Miller, Ian; Welch, Wayne
2015-09-01
High Spectral Resolution Lidar (HSRL) is typically realized using an absorption filter to separate molecular returns from particulate returns. NASA Langley Research Center (LaRC) has designed and built a Pressure-Tuned Wide-Angle Michelson Interferometer (PTWAMI) as an alternate means to separate the two types of atmospheric returns. While absorption filters only work at certain wavelengths and suffer from low photon efficiency due to light absorption, an interferometric spectral filter can be designed for any wavelength and transmits nearly all incident photons. The interferometers developed at LaRC employ an air spacer in one arm, and a solid glass spacer in the other. Field widening is achieved by specific design and selection of the lengths and refractive indices of these two arms. The principal challenge in using such an interferometer as a spectral filter for HSRL aboard aircraft is that variations in glass temperature and air pressure cause changes in the interferometer's optical path difference. Therefore, a tuning mechanism is needed to actively accommodate for these changes. The pressure-tuning mechanism employed here relies on changing the pressure in an enclosed, air-filled arm of the interferometer to change the arm's optical path length. However, tuning using pressure will not adjust for tilt, mirror warpage, or thermally induced wavefront error, so the structural, thermal, and optical behavior of the device must be well understood and optimized in the design and manufacturing process. The PTWAMI has been characterized for particulate transmission ratio, wavefront error, and tilt, and shows acceptable performance for use in an HSRL instrument.
Femilis® 60 Levonorgestrel-Releasing Intrauterine System—A Review of 10 Years of Clinical Experience
Wildemeersch, Dirk; Andrade, Amaury; Goldstuck, Norman
2016-01-01
OBJECTIVE The aim of this study was to update the clinical experience with the Femilis® 60 levonorgestrel-releasing intrauterine system (LNG-IUS), now up to 10 years in parous and nulliparous women, particularly with regard to ease and safety of insertion, contraceptive performance, retention, acceptability, continuation of use, impact on menstrual blood loss (MBL), and duration of action. STUDY DESIGN Using the Femilis® 60 LNG-IUS releasing 20 µg of levonorgestrel/day, the following studies were conducted: an open, prospective noncomparative contraceptive study, an MBL study, a perimenopausal study, a study for the treatment of endometrial hyperplasia, and early cancer of the uterus, a residue study. RESULTS A total of 599 Femilis LNG-IUS were inserted in various clinical trials, the majority for contraceptive purposes. The total exposure in the first and second contraceptive studies, covering 558 parous and nulliparous women, was 32,717 woman-months. Femilis has high contraceptive effectiveness as only one pregnancy occurred. Expulsion of the LNG-IUS was rare with only two total and no partial expulsions (stem protruding through the cervical canal) occurred. Femilis was well tolerated, with continuation rates remaining high. Several MBL studies were conducted, totaling 80 heavy and normal menstrual bleeders, using the pictorial bleeding assessment chart method or the quantitative alkaline hematin technique. Virtually all women responded well with strongly reduced menstrual bleeding. Amenorrhea rates were high, up to 80% after three months, and ferritin levels simultaneously increased significantly. The Femilis LNG-IUS was tested in 104 symptomatic perimenopausal women for seamless transition to and through menopause, adding estrogen therapy when required. Patient tolerability appeared high as >80% requested a second and a third LNG-IUS. Twenty women presenting with nonatypical and atypical hyperplasia and one woman presenting with early endometrial carcinoma were treated with Femilis LNG-IUS. All histology specimens showed full regression, and patients remained in remission without signs of hyperplasia or cancer at yearly and ongoing follow-up examinations up to 10 years. Residual content of LNG was measured in 37 women having the Femilis LNG-IUS for up to 10 years. In 10 of the 102 women who had the Femilis 60 in situ for 10 years between 20% and 30% of the original 60 mg was recovered confirming the long duration of action of the Femilis 60 LNG-IUS. CONCLUSION These studies suggest that the Femilis 60 LNG-IUS releasing 20 µg of LNG/day is an effective, well-tolerated, and well-retained contraceptive both in parous and in nulliparous women. The design of the LNG-IUS, with flexible transverse arm(s) length of 28 mm, allows for a simplification of the insertion technique and training requirements facilitating the use by nonspecialist providers in either developed or developing countries. For nulliparous women, additional evaluation of devices with a 24 mm transverse arm(s), as it relates to tolerability, retention, and continuation of use, still needs to be undertaken. PMID:27547046
Ma, Hui-Ing; Hwang, Wen-Juh; Wang, Ching-Yi; Fang, Jing-Jing; Leong, Iat-Fai; Wang, Tsui-Ying
2012-10-01
We used a trunk-assisted prehension task to examine the effect of task (reaching for stationary vs. moving targets) and environmental constraints (virtual reality [VR] vs. physical reality) on the temporal control of trunk and arm motions in people with Parkinson's disease (PD). Twenty-four participants with PD and 24 age-matched controls reached for and grasped a ball that was either stationary or moving along a ramp 120% of arm length away. In a similar VR task, participants reached for a virtual ball that was either stationary or moving. Movement speed was measured as trunk and arm movement times (MTs); trunk-arm coordination was measured as onset interval and offset interval between trunk and arm motions, as well as a summarized index-desynchrony score. In both VR and physical reality, the PD group had longer trunk and arm MTs than the control group when reaching for stationary balls (p<.001). When reaching for moving balls in VR and physical reality, however, the PD group had lower trunk and arm MTs, onset intervals, and desynchrony scores (p<.001). For the PD group, VR induced shorter trunk MTs, shorter offset intervals, and lower desynchrony scores than did physical reality when reaching for moving balls (p<.001). These findings suggest that using real moving targets in trunk-assisted prehension tasks improves the speed and synchronization of trunk and arm motions in people with PD, and that using virtual moving targets may induce a movement termination strategy different from that used in physical reality. Copyright © 2012 Elsevier B.V. All rights reserved.
Pawłowska, Katarzyna; Umławska, Wioleta; Iwańczak, Barbara
2018-04-27
To investigate nutritional status and growth status of pediatric patients with functional gastrointestinal disorders (FGIDs) and to examine the relationship between nutritional status and linear growth in these children. In total, 102 pediatric patients diagnosed with functional constipation (FC), irritable bowel syndrome (IBS), or functional abdominal pain (FAP) in years 2013-2015 were subjected to anthropometric measurements. Anthropometry comprised body height, leg and trunk lengths, body weight, mid-upper arm circumference, and 3 skinfold thicknesses. Body fat percentage was obtained with bioelectrical impedance analysis. Indices of the nutritional status and body proportions were calculated and adjusted for age and sex. Excessive body weight and excessive fatness were the most common in children with IBS. Being underweight was most common in children with FAP, but fat deficiency was similarly frequent in the FAP and in FC groups. Short stature was the most common in children with FC. Children with IBS were the best nourished and the tallest for age and sex due to increased trunk length. Body height and linear body proportions adjusted for age and sex were positively associated with body weight and body fatness in the total sample. Children with FGIDs present various linear growth abnormalities that are associated with body weight and body fatness. Although excessive body weight and body fat are common in children with IBS, pediatricians should be aware of the risk of malnutrition in children with other FGIDs. Copyright © 2018 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Tewari, S. N.; Shah, R.
1996-01-01
Thermosolutal convection in the dendritic mushy zone occurs during directional solidification of hypoeutectic lead tin alloys in a positive thermal gradient, with the melt on the top and the solid below. This results in macrosegregation along the length of the solidified samples. The extent of macrosegregation increases with increasing primary dendrite spacings for constant mushy zone length. For constant primary spacings, the macrosegregation increases with decreasing mushy zone length. Presence of convection reduces the primary dendrite spacings. However, convection in the interdendritic melt has significantly more influence on the spacings as compared with that in the overlying melt, which is caused by the solutal buildup at the dendrite tips.
Kim, Yong Hwan; So, Wi-Young
2016-09-14
The aim of this study was to investigate the association between metabolic syndrome (MetS) and arm and leg muscle mass to total weight ratios in Korean adults. This was a randomized, controlled, cross-sectional study. Data from 2,383 adults (1,030 men and 1,353 women) were collected from the Korea National Health and Nutrition Examination Survey 2010-2011. Blood lipid profiles, blood pressure, and anthropometric characteristics, including weight, height, waist circumference, and muscle mass on dual energy X-ray absorptiometry (DXA), were evaluated in the participants. MetS was defined according to the criteria of the National Cholesterol Education Program Adult Treatment Panel III. The average mass of both arms and legs was determined using regional muscle analysis by DXA. Afterwards, the arm and leg muscle mass to total body weight ratio was determined and classified into 4 quartiles (i.e., quartile 1 [highest muscle ratio] to quartile 4 [lowest muscle ratio]). According to the arm muscle and leg muscle ratios, there was a higher prevalence of MetS in quartile 4 than in quartile 1 in both men and women. A low arm and leg muscle mass to body weight ratio was associated with a higher prevalence of MetS after adjusting for age, physical activity, frequency of smoking, and frequency of alcohol consumption. In conclusion, MetS patients demonstrated a lower arm and leg muscle mass to body weight ratio. Strength training for the lower and upper extremities is recommended because it can have a positive effect on MetS prevention.
Using shape to turn off blinking for two-colour multiexciton emission in CdSe/CdS tetrapods
Mishra, Nimai; Orfield, Noah Jeremiah; Wang, Feng; ...
2017-05-12
Here, semiconductor nanostructures capable of emitting from two excited states and thereby of producing two photoluminescence colours are of fundamental and potential technological significance. In this limited class of nanocrystals, CdSe/CdS core/arm tetrapods exhibit the unusual trait of two-colour (red and green) multiexcitonic emission, with green emission from the CdS arms emerging only at high excitation fluences. Here we show that by synthetic shape-tuning, both this multi-colour emission process, and blinking and photobleaching behaviours of single tetrapods can be controlled. Specifically, we find that the properties of dual emission and single-nanostructure photostability depend on different structural parameters—arm length and armmore » diameter, respectively—but that both properties can be realized in the same nanostructure. Furthermore, based on results of correlated photoluminescence and transient absorption measurements, we conclude that hole-trap filling in the arms and partial state-filling in the core are necessary preconditions for the observation of multiexciton multi-colour emission.« less
Using shape to turn off blinking for two-colour multiexciton emission in CdSe/CdS tetrapods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mishra, Nimai; Orfield, Noah Jeremiah; Wang, Feng
Here, semiconductor nanostructures capable of emitting from two excited states and thereby of producing two photoluminescence colours are of fundamental and potential technological significance. In this limited class of nanocrystals, CdSe/CdS core/arm tetrapods exhibit the unusual trait of two-colour (red and green) multiexcitonic emission, with green emission from the CdS arms emerging only at high excitation fluences. Here we show that by synthetic shape-tuning, both this multi-colour emission process, and blinking and photobleaching behaviours of single tetrapods can be controlled. Specifically, we find that the properties of dual emission and single-nanostructure photostability depend on different structural parameters—arm length and armmore » diameter, respectively—but that both properties can be realized in the same nanostructure. Furthermore, based on results of correlated photoluminescence and transient absorption measurements, we conclude that hole-trap filling in the arms and partial state-filling in the core are necessary preconditions for the observation of multiexciton multi-colour emission.« less
Natural selection in the colloid world: active chiral spirals.
Zhang, Jie; Granick, Steve
2016-10-06
We present a model system in which to study natural selection in the colloid world. In the assembly of active Janus particles into rotating pinwheels when mixed with trace amounts of homogeneous colloids in the presence of an AC electric field, broken symmetry in the rotation direction produces spiral, chiral shapes. Locked into a central rotation point by the centre particle, the spiral arms are found to trail rotation of the overall cluster. To achieve a steady state, the spiral arms undergo an evolutionary process to coordinate their motion. Because all the particles as segments of the pinwheel arms are self-propelled, asymmetric arm lengths are tolerated. Reconfiguration of these structures can happen in various ways and various mechanisms of this directed structural change are analyzed in detail. We introduce the concept of VIP (very important particles) to express that sustainability of active structures is most sensitive to only a few particles at strategic locations in the moving self-assembled structures.
Galbany, Jordi; Abavandimwe, Didier; Vakiener, Meagan; Eckardt, Winnie; Mudakikwa, Antoine; Ndagijimana, Felix; Stoinski, Tara S; McFarlin, Shannon C
2017-07-01
Great apes show considerable diversity in socioecology and life history, but knowledge of their physical growth in natural settings is scarce. We characterized linear body size growth in wild mountain gorillas from Volcanoes National Park, Rwanda, a population distinguished by its extreme folivory and accelerated life histories. In 131 individuals (0.09-35.26 years), we used non-invasive parallel laser photogrammetry to measure body length, back width, arm length and two head dimensions. Nonparametric LOESS regression was used to characterize cross-sectional distance and velocity growth curves for males and females, and consider links with key life history milestones. Sex differences became evident between 8.5 and 10.0 years of age. Thereafter, female growth velocities declined, while males showed increased growth velocities until 10.0-14.5 years across dimensions. Body dimensions varied in growth; females and males reached 98% of maximum body length at 11.7 and 13.1 years, respectively. Females attained 95.3% of maximum body length by mean age at first birth. Neonates were 31% of maternal size, and doubled in size by mean weaning age. Males reached maximum body and arm length and back width before emigration, but experienced continued growth in head dimensions. While comparable data are scarce, our findings provide preliminary support for the prediction that mountain gorillas reach maximum body size at earlier ages compared to more frugivorous western gorillas. Data from other wild populations are needed to better understand comparative great ape development, and investigate links between trajectories of physical, behavioral, and reproductive maturation. © 2017 Wiley Periodicals, Inc.
Control of Angular Momentum during Walking in Children with Cerebral Palsy
ERIC Educational Resources Information Center
Bruijn, Sjoerd M.; Meyns, Pieter; Jonkers, Ilse; Kaat, Desloovere; Duysens, Jacques
2011-01-01
Children with hemiparetic Cerebral Palsy (CP) walk with marked asymmetries. For instance, we have recently shown that they have less arm swing on the affected side, and more arm swing at the unaffected side. Such an increase in arm swing at the unaffected side may be aimed at controlling total body angular momentum about the vertical axis,…
ERIC Educational Resources Information Center
Van Buskirk, William; London, Michael; Plump, Carolyn
2018-01-01
Traditional management education has been widely criticized for an overemphasis on rational, analytic, arms-length approaches to the detriment of softer, more intuitive capacities. Most critics agree that today's management students are overdrilled in the routines of calculation and analysis, but underprepared for the dynamic and turbulent…
NASA Mars Rover Curiosity at JPL, Side View
2011-04-06
The rover for NASA Mars Science Laboratory mission, named Curiosity, is about 3 meters 10 feet long, not counting the additional length that the rover arm can be extended forward. The front of the rover is on the left in this side view.
Flexural Stiffness of Myosin Va Subdomains as Measured from Tethered Particle Motion
Michalek, Arthur J.; Kennedy, Guy G.; Warshaw, David M.; Ali, M. Yusuf
2015-01-01
Myosin Va (MyoVa) is a processive molecular motor involved in intracellular cargo transport on the actin cytoskeleton. The motor's processivity and ability to navigate actin intersections are believed to be governed by the stiffness of various parts of the motor's structure. Specifically, changes in calcium may regulate motor processivity by altering the motor's lever arm stiffness and thus its interhead communication. In order to measure the flexural stiffness of MyoVa subdomains, we use tethered particle microscopy, which relates the Brownian motion of fluorescent quantum dots, which are attached to various single- and double-headed MyoVa constructs bound to actin in rigor, to the motor's flexural stiffness. Based on these measurements, the MyoVa lever arm and coiled-coil rod domain have comparable flexural stiffness (0.034 pN/nm). Upon addition of calcium, the lever arm stiffness is reduced 40% as a result of calmodulins potentially dissociating from the lever arm. In addition, the flexural stiffness of the full-length MyoVa construct is an order of magnitude less stiff than both a single lever arm and the coiled-coil rod. This suggests that the MyoVa lever arm-rod junction provides a flexible hinge that would allow the motor to maneuver cargo through the complex intracellular actin network. PMID:26770194
Keresztényi, Zoltán; Cesari, Paola; Fazekas, Gábor; Laczkó, József
2009-03-01
Variances of drawing arm movements between patients with Parkinson's disease and healthy controls were compared. The aim was to determine whether differences in joint synergies or individual joint rotations affect the endpoint (hand position) variance. Joint and endpoint coordinates were measured while participants performed drawing tasks. Variances of arm configurations and endpoints were computed and statistically analyzed for 12 patients and 12 controls. The variance of arm movements for patients (both for arm configuration and endpoint) was overall higher than that for the control group. Variation was smaller for drawing a circle versus a square and for drawing with the dominant versus the nondominant hand within both groups. The ratio of arm configuration variances between groups was similar to the ratio of endpoint variances. There were significant differences in the velocity, but not in the path lengths of movements comparing the two groups. Patients presented less movement stability while drawing different figures in different trials. Moreover, the similarity of the ratios suggests that the ill-coordinated hand movement was caused by the error in the movements of individual body parts rather than by the lack of intersegmental coordination. Thus, rehabilitation may focus on the improvement of the precision of individual joint rotations.
Wolfram, Susann; Morse, Christopher I; Winwood, Keith L; Hodson-Tole, Emma; McEwan, Islay M
2018-01-01
The triceps surae primarily acts as plantarflexor of the ankle joint. However, the group also causes inversion and eversion at the subtalar joint. Despite this, the Achilles tendon moment arm is generally measured without considering the potential influence of inversion/eversion of the foot during plantarflexion. This study investigated the effect of foot inversion and eversion on the plantarflexion Achilles tendon moment arm. Achilles tendon moment arms were determined using the centre-of-rotation method in magnetic resonance images of the left ankle of 11 participants. The foot was positioned at 15° dorsiflexion, 0° or 15° plantarflexion using a Styrofoam wedge. In each of these positions, the foot was either 10° inverted, neutral or 10° everted using an additional Styrofoam wedge. Achilles tendon moment arm in neutral foot position was 47.93 ± 4.54 mm and did not differ significantly when the foot was positioned in 10° inversion and 10° eversion. Hence, inversion/eversion position of the foot may not considerably affect the length of the Achilles tendon moment arm. This information could be useful in musculoskeletal models of the human lower leg and foot and when estimating Achilles tendon forces during plantarflexion with the foot positioned in inversion or eversion.
Chitapanarux, Imjai; Tharavichitkul, Ekkasit; Kamnerdsupaphon, Pimkhuan; Pukanhapan, Nantaka; Vongtama, Roy
2013-01-01
The aim of this study was to compare the efficacy and safety of concurrent chemoradiotherapy (CCRT) vs accelerated hyperfractionation with concomitant boost (CCB) as a primary treatment for patients with Stage III–IV squamous cell carcinoma of head and neck (SCCHN). A total of 85 non-metastatic advanced SCCHN patients were accrued from January 2003 to December 2007. Of these, 48 and 37 patients received CCRT and CCB, respectively. The patients were randomized to receive either three cycles of carboplatin and 5-fluorouracil plus conventional radiotherapy (CCRT, 66 Gy in 6.5 weeks) or hybrid accelerated radiotherapy (CCB, 70 Gy in 6 weeks). The primary endpoint was determined by locoregional control rate. The secondary endpoints were overall survival and toxicity. With a median follow-up of 43 months (range, 3–102), the 5-year locoregional control rate was 69.6% in the CCRT arm vs 55.0% in the CCB arm (P = 0.184). The 5-year overall survival rate was marginally significantly different (P = 0.05): 76.1% in the CCRT arm vs 63.5% in the CCB arm. Radiotherapy treatment interruptions of more than three days were 60.4% and 40.5% in the CCRT arm and CCB arm, respectively. The median total treatment time was 55.5 days in the CCRT arm and 49 days in the CCB arm. The rate of Grade 3–4 acute mucositis was significantly higher in the CCB arm (67.6% vs 41.7%, P = 0.01), but no high grade hematologic toxicities were found in the CCB arm (27.2% vs 0%). CCRT has shown a trend of improving outcome over CCB irradiation in locoregionally advanced head and neck cancer. PMID:23740894
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bensadoun, Rene-Jean; Benezery, Karen; Dassonville, Olivier
Background: Unresectable carcinomas of the oropharynx and hypopharynx still have a poor long-term prognosis. Following a previous phase II study, this phase III multicenter trial was conducted between November 1997 and March 2002. Methods: Nontreated, strictly unresectable cases were eligible. Twice-daily radiation: two fractions of 1.2 Gy/day, 5 days per week, with no split (D1{sup {yields}}D46). Total tumor doses: 80.4 Gy/46 day (oropharynx), 75.6 Gy/44 day (hypopharynx). Chemotherapy (arm B): Cisplatin 100 mg/m{sup 2} (D1, D22, D43); 5FU, continuous infusion (D1{sup {yields}}D5), 750 mg/m{sup 2}/day cycle 1; 430 mg/m{sup 2}/day cycles 2 and 3. Results: A total of 163 evaluablemore » patients. Grade 3-4 acute mucositis 82.6% arm B/69.5% arm A (NS); Grade 3-4 neutropenia 33.3% arm B/2.4% arm A (p < 0.05). Enteral nutrition through gastrostomy tube was more frequent in arm B before treatment and at 6 months (p < 0.01). At 24 months, overall survival (OS), disease-free survival (DFS), and specific survival (SS) were significantly better in arm B. OS: 37.8% arm B vs. 20.1% arm A (p = 0.038); DFS: 48.2% vs. 25.2% (p = 0.002); SS: 44.5% vs. 30.2% (p 0.021). No significant difference between the two arms in the amount of side effects at 1 and 2 years. Conclusion: For these unresectable cases, chemoradiation provides better outcome than radiation alone, even with an 'aggressive' dose-intensity radiotherapy schedule.« less
Shinoda, Masayuki; Ando, Nobutoshi; Kato, Ken; Ishikura, Satoshi; Kato, Hoichi; Tsubosa, Yasuhiro; Minashi, Keiko; Okabe, Hiroshi; Kimura, Yusuke; Kawano, Tatsuyuki; Kosugi, Shin-Ichi; Toh, Yasushi; Nakamura, Kenichi; Fukuda, Haruhiko
2015-01-01
Low-dose cisplatin and 5-fluorouracil (LDPF) chemotherapy with daily radiotherapy (RT) is used as an alternative chemoradiotherapy regimen for locally advanced esophageal carcinoma. We evaluated whether RT plus LDPF chemotherapy had an advantage in terms of survival and/or toxicity over RT plus standard-dose cisplatin and 5-fluorouracil (SDPF) chemotherapy in this study. This multicenter trial included esophageal cancer patients with clinical T4 disease and/or unresectable regional lymph node metastasis. Patients were randomly assigned to receive RT (2 Gy/fraction, total dose of 60 Gy) with SDPF (arm A) or LDPF (arm B) chemotherapy. The primary endpoint was overall survival (OS). A total of 142 patients (arm A/B, 71/71) from 41 institutions were enrolled between April 2004 and September 2009. The OS hazard ratio in arm B versus arm A was 1.05 (80% confidence interval, 0.78–1.41). There were no differences in toxicities in either arm. Arm B was judged as not promising for further evaluation in the phase III setting. Thus, the Data and Safety Monitoring Committee recommended that the study be terminated. In the updated analyses, median OS and 3-year OS were 13.1 months and 25.9%, respectively, for arm A and 14.4 months and 25.7%, respectively, for arm B. Daily RT plus LDPF chemotherapy did not qualify for further evaluation as a new treatment option for patients with locally advanced unresectable esophageal cancer. This study was registered at the UMIN Clinical Trials Registry as UMIN000000861. PMID:25640628
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akahane, Akio, E-mail: a.akahane@gmail.com; Sone, Miyuki; Ehara, Shigeru
2011-12-15
Purpose: This study was designed to compare central venous ports (CVP) from two different routes of venous access-the subclavian vein and arm vein-in terms of safety for patients with head and neck cancer (HNC). Methods: Patients with HNC who underwent image-guided implantations of CVPs were retrospectively evaluated. All CVPs were implanted under local anesthesia. Primary outcome measurements were rates and types of adverse events (AEs). Secondary outcomes included technical success and rate and reason of CVP removal. Results: A total of 162 patients (subclavian port group, 47; arm port group, 115) were included in this study. Technical success was achievedmore » in all patients. The median follow-up period was 94 (range, 1-891) days. Two patients in the subclavian port group experienced periprocedural complications. Postprocedural AEs were observed in 8.5 and 22.6% of the subclavian port and arm port group patients, respectively (P = 0.044). Phlebitis and system occlusions were observed only in the arm port group. The rate of infection was not significantly different between the two groups. The CVP was removed in 34 and 39.1% of the subclavian port and arm port patients, respectively. Conclusions: Both subclavian and arm CVPs are feasible in patients with HNC. AEs were more frequent in the arm port group; thus, the arm port is not recommended as the first choice for patients with HNC. However, further experience is needed to improve the placement technique and the maintenance of CVPs and a prospective analysis is warranted.« less
The Effect of Distal Location of the Volar Short Arm Splint on the Metacarpophalangeal Joint Motion.
Kim, Joon Yub; Sohn, Dong Wook; Park, Ho Youn; Yoo, Jeong Hyun; Kim, Joo Hak; Jung, Myung Gon; Cho, Jae Ho
2016-06-01
The goals of this study were to compare maximal metacarpophalangeal joint (MCPJ) flexion angles after application of a volar short arm splint at 3 different locations and verify the relations between the three different physical and radiological locations. Forty dominant hands of healthy subjects were analyzed in the study. We defined a transverse skin folding line as a line drawn from the radial aspect of the thenar crease to the ulnar aspect of the distal transverse palmar crease. The distal end of the volar short arm splint was applied on 3 parallel locations to this line. Location A was on this transverse skin folding line; location B was 1 cm proximal to location A; and location C was 1 cm distal to location A. Two orthopedic surgeons measured the maximal MCPJ flexion angles of each finger except the thumb with the application of a volar short arm splint at 3 different locations as well as without a splint as a control. Radiological locations of the 3 different distal ends of the volar short arm splint were also assessed by anteroposterior radiographs of the wrist. When the splint was applied at location A and C, the maximal MCPJ flexion angle decreased to a mean of 83° (91% of control value) and 56° (62% of control value), respectively (compared to the control, p < 0.001). At location B, the maximal MCPJ flexion angle was a mean of 90° (99% of control value); no significant difference was observed compared to the control or without the splint (p = 0.103). On radiography, the average length from the metacarpal head to the distal end of the splint at all fingers decreased in the order of location B, A, and C (29 mm, 19 mm, and 10 mm, respectively; p < 0.001). We recommend applying the distal end of a volar short arm splint at proximal 1 cm to the transverse skin folding line to preserve MCPJ motion perfectly, which is located at distal 44% of the whole metacarpal bone length radiologically.
Focus collimator press for a collimator for gamma ray cameras
DOE Office of Scientific and Technical Information (OSTI.GOV)
York, R.N.; York, D.L.
A focus collimator press for collimators for gamma ray cameras is described comprising a pivot arm of fixed length mounted on a travelling pivot which is movable in the plane of a spaced apart work table surface in a direction toward and away from the work table. A press plate is carried at the opposite end of the fixed length pivot arm, and is maintained in registration with the same portion of the work table for pressing engagement with each undulating radiation opaque strip as it is added to the top of a collimator stack in process by movement ofmore » the travelling pivot inward toward the work table. This enables the press plate to maintain its relative position above the collimator stack and at the same time the angle of the press plate changes, becoming less acute in relation to the work table as the travelling pivot motes inwardly toward the work table. The fixed length of the pivot arm is substantially equal to the focal point of the converging apertures formed by each pair of undulating strips stacked together. Thus, the focal point of each aperture row falls substantially on the axis of the travelling pivot, and since it moves in the plane of the work table surface the focal point of each aperture row is directed to lie in the same common plane. When one of two collimator stacks made in this way is rotated 180 degrees and the two bonded together along their respective first strips, all focal points of every aperture row lie on the central axis of the completed collimator.« less
Effects of Aging on Arm Swing during Gait: The Role of Gait Speed and Dual Tasking.
Mirelman, Anat; Bernad-Elazari, Hagar; Nobel, Tomer; Thaler, Avner; Peruzzi, Agnese; Plotnik, Meir; Giladi, Nir; Hausdorff, Jeffrey M
2015-01-01
Healthy walking is characterized by pronounced arm swing and axial rotation. Aging effects on gait speed, stride length and stride time variability have been previously reported, however, less is known about aging effects on arm swing and axial rotation and their relationship to age-associated gait changes during usual walking and during more challenging conditions like dual tasking. Sixty healthy adults between the ages of 30-77 were included in this study designed to address this gap. Lightweight body fixed sensors were placed on each wrist and lower back. Participants walked under 3 walking conditions each of 1 minute: 1) comfortable speed, 2) walking while serially subtracting 3's (Dual Task), 3) walking at fast speed. Aging effects on arm swing amplitude, range, symmetry, jerk and axial rotation amplitude and jerk were compared between decades of age (30-40; 41-50; 51-60; 61-77 years). As expected, older adults walked slower (p = 0.03) and with increased stride variability (p = 0.02). Arm swing amplitude decreased with age under all conditions (p = 0.04). In the oldest group, arm swing decreased during dual task and increased during the fast walking condition (p<0.0001). Similarly, arm swing asymmetry increased during the dual task in the older groups (p<0.004), but not in the younger groups (p = 0.67). Significant differences between groups and within conditions were observed in arm swing jerk (p<0.02), axial rotation amplitude (p<0.02) and axial jerk (p<0.001). Gait speed, arm swing amplitude of the dominant arm, arm swing asymmetry and axial rotation jerk were all independent predictors of age in a multivariate model. These findings suggest that the effects of gait speed and dual tasking on arm swing and axial rotation during walking are altered among healthy older adults. Follow-up work is needed to examine if these effects contribute to reduced stability in aging.
Effects of Aging on Arm Swing during Gait: The Role of Gait Speed and Dual Tasking
Mirelman, Anat; Bernad-Elazari, Hagar; Nobel, Tomer; Thaler, Avner; Peruzzi, Agnese; Plotnik, Meir; Giladi, Nir; Hausdorff, Jeffrey M.
2015-01-01
Healthy walking is characterized by pronounced arm swing and axial rotation. Aging effects on gait speed, stride length and stride time variability have been previously reported, however, less is known about aging effects on arm swing and axial rotation and their relationship to age-associated gait changes during usual walking and during more challenging conditions like dual tasking. Sixty healthy adults between the ages of 30–77 were included in this study designed to address this gap. Lightweight body fixed sensors were placed on each wrist and lower back. Participants walked under 3 walking conditions each of 1 minute: 1) comfortable speed, 2) walking while serially subtracting 3’s (Dual Task), 3) walking at fast speed. Aging effects on arm swing amplitude, range, symmetry, jerk and axial rotation amplitude and jerk were compared between decades of age (30–40; 41–50; 51–60; 61–77 years). As expected, older adults walked slower (p = 0.03) and with increased stride variability (p = 0.02). Arm swing amplitude decreased with age under all conditions (p = 0.04). In the oldest group, arm swing decreased during dual task and increased during the fast walking condition (p<0.0001). Similarly, arm swing asymmetry increased during the dual task in the older groups (p<0.004), but not in the younger groups (p = 0.67). Significant differences between groups and within conditions were observed in arm swing jerk (p<0.02), axial rotation amplitude (p<0.02) and axial jerk (p<0.001). Gait speed, arm swing amplitude of the dominant arm, arm swing asymmetry and axial rotation jerk were all independent predictors of age in a multivariate model. These findings suggest that the effects of gait speed and dual tasking on arm swing and axial rotation during walking are altered among healthy older adults. Follow-up work is needed to examine if these effects contribute to reduced stability in aging. PMID:26305896
How do deltoid muscle moment arms change after reverse total shoulder arthroplasty?
Walker, David R; Struk, Aimee M; Matsuki, Keisuke; Wright, Thomas W; Banks, Scott A
2016-04-01
Although many advantages of reverse total shoulder arthroplasty (RTSA) have been demonstrated, a variety of complications indicate there is much to learn about how RTSA modifies normal shoulder function. This study used a subject-specific computational model driven by in vivo kinematic data to assess how RTSA affects deltoid muscle moment arms after surgery. A subject-specific 12 degree-of-freedom musculoskeletal model was used to analyze the shoulders of 26 individuals (14 RTSA and 12 normal). The model was modified from the work of Holzbaur to directly input 6 degree-of-freedom humeral and scapular kinematics obtained using fluoroscopy. The moment arms of the anterior, lateral, and posterior aspects of the deltoid were significantly different when RTSA and normal cohorts were compared at different abduction angles. Anterior and lateral deltoid moment arms were significantly larger in the RTSA group at the initial elevation of the arm. The posterior deltoid was significantly larger at maximum elevation. There was large intersubject variability within the RTSA group. Placement of implant components during RTSA can directly affect the geometric relationship between the humerus and scapula and the muscle moment arms in the RTSA shoulder. RTSA shoulders maintain the same anterior and posterior deltoid muscle moment-arm patterns as healthy shoulders but show much greater intersubject variation and larger moment-arm magnitudes. These observations provide a basis for determining optimal implant configuration and surgical placement to maximize RTSA function in a patient-specific manner. Published by Elsevier Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marnitz, Simone, E-mail: simone.marnitz-schulze@uk-koeln.de; Martus, Peter; Köhler, Christhardt
Purpose: The Uterus-11 trial was designed to evaluate the role of surgical staging in patients with cervical cancer before primary chemoradiation therapy (CRT). The present report provides the toxicity data stratified by the treatment arm and technique. Methods and Materials: A total of 255 patients with carcinoma of the uterine cervix (International Federation of Gynecology and Obstetrics stage IIB-IVA) were randomized to either surgical staging followed by CRT (arm A) or clinical staging followed by CRT (arm B). Patients with para-aortic metastases underwent extended field radiation therapy (RT). Brachytherapy was mandatory. The present report presents the acute therapy-related toxicities stratifiedmore » by treatment arm and radiation technique. Results: A total of 240 patients were eligible (n=121 in arm A; n=119 in arm B). Of the 240 patients, 236 (98.3%) underwent external beam RT with a median total dose of 50.4 Gy. The mean treatment duration was 53 days. Of the patients, 60% underwent intensity modulated RT (IMRT). A total of 234 patients (97.5%) underwent chemotherapy, and 231 (96.3%) underwent brachytherapy, with a median single dose of 6 Gy covering the tumor to a median nominal total dose of 28 Gy. Treatment was well tolerated, with 0% grade ≥3 genitourinary and gastrointestinal toxicity, 6% grade 3 nausea, 3% grade 3 vomiting, and <2% grade 3 diarrhea. More patients after surgical staging experienced grade 2 anemia (54.3% in arm A vs 45.3% in arm B; P=.074) and grade 2 leukocytopenia (41.4% vs 31.6%; P=.56). Of the patients who received IMRT versus a 3-dimensional technique, 65.3% versus 33.7% presented with grade 2 anemia. Grade 3 gastrointestinal and grade 2 bladder toxicity were significantly reduced with the use of IMRT. Conclusions: The incidence and severity of acute therapy-related toxicity compared favorably with those from other randomized trials. Excellent adherence to treatment and treatment quality was achieved compared with patterns of care analyses. Surgical staging led to a doubled number of patients treated with extended field RT. The question of whether surgical staging is beneficial in the context of primary CRT requires further study.« less
30 CFR 1206.151 - Definitions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... interests regarding that contract. To be considered arm's length for any production month, a contract must.... Gathering means the movement of lease production to a central accumulation and/or treatment point on the... the lessee's production and to market that production. Minimum royalty means that minimum amount of...
30 CFR 1206.151 - Definitions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... interests regarding that contract. To be considered arm's length for any production month, a contract must.... Gathering means the movement of lease production to a central accumulation and/or treatment point on the... the lessee's production and to market that production. Minimum royalty means that minimum amount of...
Code of Federal Regulations, 2010 CFR
2010-07-01
... interests regarding that contract. To be considered arm's length for any production month, a contract must.... Gathering means the movement of lease production to a central accumulation and/or treatment point on the... the lessee's production and to market that production. Minimum royalty means that minimum amount of...
Assessing body composition in infants and toddlers
USDA-ARS?s Scientific Manuscript database
The objective of this study was to compare different body composition techniques in infants and toddlers. Anthropometric measures including mid-upper arm circumference (MAC), triceps skinfold thickness (TSF), and weight-for-height or -length Z-scores (WHZ), and measures of body fat mass assessed wit...
Uçkay, Ilker; von Dach, Elodie; Perez, Cédric; Agostinho, Americo; Garnerin, Philippe; Lipsky, Benjamin A; Hoffmeyer, Pierre; Pittet, Didier
2017-07-01
To assess the optimal surgical approach and costs for patients hospitalized with septic bursitis. From May 1, 2011, through December 24, 2014, hospitalized patients with septic bursitis at University of Geneva Hospitals were randomized (1:1) to receive 1- vs 2-stage bursectomy. All the patients received postsurgical oral antibiotic drug therapy for 7 days. Of 164 enrolled patients, 130 had bursitis of the elbow and 34 of the patella. The surgical approach used was 1-stage in 79 patients and 2-stage in 85. Overall, there were 22 treatment failures: 8 of 79 patients (10%) in the 1-stage arm and 14 of 85 (16%) in the 2-stage arm (Pearson χ 2 test; P=.23). Recurrent infection was caused by the same pathogen in 7 patients (4%) and by a different pathogen in 5 (3%). Outcomes were better in the 1- vs 2-stage arm for wound dehiscence for elbow bursitis (1 of 66 vs 9 of 64; Fisher exact test P=.03), median length of hospital stay (4.5 vs 6.0 days), nurses' workload (605 vs 1055 points), and total costs (Sw₣6881 vs Sw₣11,178; all P<.01). For adults with moderate to severe septic bursitis requiring hospital admission, bursectomy with primary closure, together with antibiotic drug therapy for 7 days, was safe, effective, and resource saving. Using a 2-stage approach may be associated with a higher rate of wound dehiscence for olecranon bursitis than the 1-stage approach. Clinicaltrials.gov Identifier: NCT01406652. Copyright © 2017 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
Altering the N-terminal arms of the polymerase manager protein UmuD modulates protein interactions.
Murison, David A; Ollivierre, Jaylene N; Huang, Qiuying; Budil, David E; Beuning, Penny J
2017-01-01
Escherichia coli cells that are exposed to DNA damaging agents invoke the SOS response that involves expression of the umuD gene products, along with more than 50 other genes. Full-length UmuD is expressed as a 139-amino-acid protein, which eventually cleaves its N-terminal 24 amino acids to form UmuD'. The N-terminal arms of UmuD are dynamic and contain recognition sites for multiple partner proteins. Cleavage of UmuD to UmuD' dramatically affects the function of the protein and activates UmuC for translesion synthesis (TLS) by forming DNA Polymerase V. To probe the roles of the N-terminal arms in the cellular functions of the umuD gene products, we constructed additional N-terminal truncated versions of UmuD: UmuD 8 (UmuD Δ1-7) and UmuD 18 (UmuD Δ1-17). We found that the loss of just the N-terminal seven (7) amino acids of UmuD results in changes in conformation of the N-terminal arms, as determined by electron paramagnetic resonance spectroscopy with site-directed spin labeling. UmuD 8 is cleaved as efficiently as full-length UmuD in vitro and in vivo, but expression of a plasmid-borne non-cleavable variant of UmuD 8 causes hypersensitivity to UV irradiation, which we determined is the result of a copy-number effect. UmuD 18 does not cleave to form UmuD', but confers resistance to UV radiation. Moreover, removal of the N-terminal seven residues of UmuD maintained its interactions with the alpha polymerase subunit of DNA polymerase III as well as its ability to disrupt interactions between alpha and the beta processivity clamp, whereas deletion of the N-terminal 17 residues resulted in decreases in binding to alpha and in the ability to disrupt the alpha-beta interaction. We find that UmuD 8 mimics full-length UmuD in many respects, whereas UmuD 18 lacks a number of functions characteristic of UmuD.
Macromolecular beta-adrenergic antagonists discriminating between receptor and antibody.
Pitha, J; Zjawiony, J; Lefkowitz, R J; Caron, M G
1980-01-01
The beta-adrenergic antagonist, alprenolol, was attached in an irreversible manner to macromolecular dextran via side arms that differed in length. The ability of these macromolecules to bind to the beta-adrenergic receptor of frog erythrocytes and to catecholamine-binding antibodies raised against partially purified receptors was studied. Compared to the parent drug the potency of binding of macromolecular alprenolol to the receptor decreased about 1/10, 1/600, and 1/8000 when the length of the arm separating alprenolol from the dextran moiety was 13, 8, and 4 atoms, respectively. In contrast, the binding potencies of the parent drug and of all its macromolecular derivatives for the antibody were within the same order of magnitude. Thus, conversion of a drug to a macromolecular form may not only sustain its binding activity but may also lead in a higher selectivity. The macromolecular derivatives described here may be suitable probes for investigation of the location and of the molecular properties of the binding sites for beta-adrenergic drugs. PMID:6154947
Goto, Ryosuke; Kumakura, Hiroo
2013-05-01
In this study we compared the power arm lengths and mechanical advantages attributed to 12 lower leg muscles across three prosimian species. The origins and insertions of the lower leg muscles in Garnett's galago, the ring-tailed lemur, and the slow loris were quantified and correlated with positional behaviour. The ankle joint of the galago has a speed-oriented mechanical system, in contrast to that of the slow loris, which exhibits more power-oriented mechanics. The lemur ankle joint exhibited intermediate power arm lengths and an intermediate mechanical advantage relative to the other primates. This result suggests that the mechanical differences in the ankle between the galago and the lemur, taxa that exhibit similar locomotory repertoires, reflect a difference in the kinematics and kinetics of leaping (i.e. generalised vs. specialised leapers). In contrast to leaping primates, lorises have developed a more power-oriented mechanical system as a foot adaptation for positional behaviours such as bridging or cantilevering in their arboreal habitat. © 2013 Anatomical Society.
Tolerance at arm's length: the Dutch experience.
Schuijer, J
1990-01-01
With respect to pedophilia and the age of consent, the Netherlands warrants special attention. Although pedophilia is not as widely accepted in the Netherlands as sometimes is supposed, developments in the judicial practice showed a growing reservedness. These developments are a spin-off of related developments in Dutch society. The tolerance in the Dutch society has roots that go far back in history and is also a consequence of the way this society is structured. The social changes of the sixties and seventies resulted in a "tolerance at arm's length" for pedophiles, which proved to be deceptive when the Dutch government proposed to lower the age of consent in 1985. It resulted in a vehement public outcry. The prevailing sex laws have been the prime target of protagonists of pedophile emancipation. Around 1960, organized as a group, they started to undertake several activities. In the course of their existence, they came to redefine the issue of pedophilia as one of youth emancipation.
Coordination of rapid stepping with arm pointing: anticipatory changes and step adaptation.
Yiou, Eric; Schneider, Cyril; Roussel, Didier
2007-06-01
The present study explored whether rapid stepping is influenced by the coordination of an arm pointing task. Nine participants were instructed to (a) point the index finger of the dominant arm towards a target from the standing posture, (b) initiate a rapid forward step with the contralateral leg, and (c) synchronize stepping and pointing (combined task). Force plate and ankle muscle electromyography (EMG) recordings were contrasted between (b) and (c). In the combined task, the arm acceleration trace most often peaked around foot-off, coinciding with a 15% increase in the forward acceleration of the center of gravity (CoG). Backward displacement of the center of foot pressure at foot-off, duration of anticipatory postural adjustments (APAs) and ankle muscle EMG activity remained unchanged. In contrast, durations of swing phase and whole step were reduced and step length was smaller in the combined task. A reduction in the swing phase was correlated with an increased CoG forward acceleration at foot-off. Changes in the biomechanics of step initiation during the combined task might be ascribed to the postural dynamics elicited by arm pointing, and not to a modulation of the step APAs programming.
Arm to leg coordination in elite butterfly swimmers.
Chollet, D; Seifert, L; Boulesteix, L; Carter, M
2006-04-01
This study proposed the use of four time gaps to assess arm-to-leg coordination in the butterfly stroke at increasing race paces. Fourteen elite male swimmers swam at four velocities corresponding to the appropriate paces for, respectively, the 400-m, 200-m, 100-m, and 50-m events. The different stroke phases of the arm and leg were identified by video analysis and then used to calculate four time gaps (T1: time gap between entry of the hands in the water and the high break-even point of the first undulation; T2: time gap between the beginning of the hands' backward movement and the low break-even point of the first undulation; T3: time gap between the hands' arrival in a vertical plane to the shoulders and the high break-even point of the second undulation; T4: time gap between the hands' release from the water and the low break-even point of the second undulation), the values of which described the changing relationship of arm to leg movements over an entire stroke cycle. With increases in pace, elite swimmers increased the stroke rate, the relative duration of the arm pull, the recovery and the first downward movement of the legs, and decreased the stroke length, the relative duration of the arm catch phase and the body glide with arms forward (measured by T2), until continuity in the propulsive actions was achieved. Whatever the paces, the T1, T3, and T4 values were close to zero and revealed a high degree of synchronisation at key motor points of the arm and leg actions. This new method to assess butterfly coordination could facilitate learning and coaching by situating the place of the leg undulation in relation with the arm stroke.
NASA Technical Reports Server (NTRS)
1988-01-01
Martin Marietta Aero and Naval Systems has advanced the CAD art to a very high level at its Robotics Laboratory. One of the company's major projects is construction of a huge Field Material Handling Robot for the Army's Human Engineering Lab. Design of FMR, intended to move heavy and dangerous material such as ammunition, was a triumph in CAD Engineering. Separate computer problems modeled the robot's kinematics and dynamics, yielding such parameters as the strength of materials required for each component, the length of the arms, their degree of freedom and power of hydraulic system needed. The Robotics Lab went a step further and added data enabling computer simulation and animation of the robot's total operational capability under various loading and unloading conditions. NASA computer program (IAC), integrated Analysis Capability Engineering Database was used. Program contains a series of modules that can stand alone or be integrated with data from sensors or software tools.
A measure of smoking abstinence-related motivational engagement: Development and initial validation
Heckman, Bryan W.; Ditre, Joseph W.; Brandon, Thomas H.
2010-01-01
Introduction: Although a great deal of research has focused on measuring motivation and readiness to quit smoking, little research has assessed gross motivational changes after a smoker has made an attempt to quit smoking. Unlike previous single-item global measures of motivation to remain abstinent, we developed the abstinence-related motivational engagement (ARME) scale to evaluate the degree to which abstinence motivation is reflected by an ex-smoker’s daily experience in areas that include cognitive effort, priority, vigilance, and excitement. The aim of this study was to collect reliability and initial construct validity data on this new measure. Methods: Participants were 199 ex-smokers recruited from the community and smoking cessation Web sites. Participants completed online measures including a global motivation measure, the ARME scale, demographic questionnaire, and a measure of cessation self-efficacy. Results: The 16-item ARME questionnaire demonstrated high internal consistency reliability (α = .89). Analyses provided support for convergent, discriminant, and construct validity of the scale. ARME demonstrated the predicted correlation with a traditional measure of global cessation motivation, yet, also as predicted, only the ARME was negatively associated with length of abstinence. Moreover, as hypothesized, ex-smokers engaged in the quitting process via ongoing smoking Web site participation showed higher ARME scores than a comparison community sample. A five-item short form demonstrated similar psychometric properties. Discussion: This study provided initial support for the ARME construct and offers two versions of a reliable instrument for assessing this construct. Future research will examine the ARME as a predictor of cessation outcome and a potential target for relapse prevention. PMID:20190004
A measure of smoking abstinence-related motivational engagement: development and initial validation.
Simmons, Vani N; Heckman, Bryan W; Ditre, Joseph W; Brandon, Thomas H
2010-04-01
Although a great deal of research has focused on measuring motivation and readiness to quit smoking, little research has assessed gross motivational changes after a smoker has made an attempt to quit smoking. Unlike previous single-item global measures of motivation to remain abstinent, we developed the abstinence-related motivational engagement (ARME) scale to evaluate the degree to which abstinence motivation is reflected by an ex-smoker's daily experience in areas that include cognitive effort, priority, vigilance, and excitement. The aim of this study was to collect reliability and initial construct validity data on this new measure. Participants were 199 ex-smokers recruited from the community and smoking cessation Web sites. Participants completed online measures including a global motivation measure, the ARME scale, demographic questionnaire, and a measure of cessation self-efficacy. The 16-item ARME questionnaire demonstrated high internal consistency reliability (alpha = .89). Analyses provided support for convergent, discriminant, and construct validity of the scale. ARME demonstrated the predicted correlation with a traditional measure of global cessation motivation, yet, also as predicted, only the ARME was negatively associated with length of abstinence. Moreover, as hypothesized, ex-smokers engaged in the quitting process via ongoing smoking Web site participation showed higher ARME scores than a comparison community sample. A five-item short form demonstrated similar psychometric properties. This study provided initial support for the ARME construct and offers two versions of a reliable instrument for assessing this construct. Future research will examine the ARME as a predictor of cessation outcome and a potential target for relapse prevention.
30 CFR 1206.151 - Definitions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... interests regarding that contract. To be considered arm's length for any production month, a contract must.... Gathering means the movement of lease production to a central accumulation and/or treatment point on the... is to acquire only the lessee's production and to market that production. Minimum royalty means that...
27 CFR 447.42 - Application for permit.
Code of Federal Regulations, 2011 CFR
2011-04-01
... EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION IMPORTATION OF ARMS, AMMUNITION AND IMPLEMENTS OF... ammunition only, ball, wadcutter, shot, etc.); (C) The caliber, gauge, or size; (D) The model; (E) The length... the firearm, firearm barrel, ammunition, or other defense article to be imported; (K) The category of...
27 CFR 447.42 - Application for permit.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION IMPORTATION OF ARMS, AMMUNITION AND... ammunition only, ball, wadcutter, shot, etc.); (C) The caliber, gauge, or size; (D) The model; (E) The length... the firearm, firearm barrel, ammunition, or other defense article to be imported; (K) The category of...
27 CFR 447.42 - Application for permit.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION IMPORTATION OF ARMS, AMMUNITION AND... ammunition only, ball, wadcutter, shot, etc.); (C) The caliber, gauge, or size; (D) The model; (E) The length... the firearm, firearm barrel, ammunition, or other defense article to be imported; (K) The category of...
27 CFR 447.42 - Application for permit.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION IMPORTATION OF ARMS, AMMUNITION AND... ammunition only, ball, wadcutter, shot, etc.); (C) The caliber, gauge, or size; (D) The model; (E) The length... the firearm, firearm barrel, ammunition, or other defense article to be imported; (K) The category of...
27 CFR 447.42 - Application for permit.
Code of Federal Regulations, 2012 CFR
2012-04-01
... EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION IMPORTATION OF ARMS, AMMUNITION AND IMPLEMENTS OF... ammunition only, ball, wadcutter, shot, etc.); (C) The caliber, gauge, or size; (D) The model; (E) The length... the firearm, firearm barrel, ammunition, or other defense article to be imported; (K) The category of...
50 CFR 600.1000 - Definitions.
Code of Federal Regulations, 2013 CFR
2013-10-01
....1009. Borrower means, individually and collectively, each post-reduction fishing permit holder and/or... “ex-vessel value” as used in section 312 of the Magnuson Act. Deposit principal means all collected... reduction loan. Fish buyer means the first ex-vessel party who: (1) In an arm's—length transaction...
50 CFR 600.1000 - Definitions.
Code of Federal Regulations, 2010 CFR
2010-10-01
....1009. Borrower means, individually and collectively, each post-reduction fishing permit holder and/or... “ex-vessel value” as used in section 312 of the Magnuson Act. Deposit principal means all collected... reduction loan. Fish buyer means the first ex-vessel party who: (1) In an arm's—length transaction...
50 CFR 600.1000 - Definitions.
Code of Federal Regulations, 2011 CFR
2011-10-01
....1009. Borrower means, individually and collectively, each post-reduction fishing permit holder and/or... “ex-vessel value” as used in section 312 of the Magnuson Act. Deposit principal means all collected... reduction loan. Fish buyer means the first ex-vessel party who: (1) In an arm's—length transaction...
50 CFR 600.1000 - Definitions.
Code of Federal Regulations, 2014 CFR
2014-10-01
....1009. Borrower means, individually and collectively, each post-reduction fishing permit holder and/or... “ex-vessel value” as used in section 312 of the Magnuson Act. Deposit principal means all collected... reduction loan. Fish buyer means the first ex-vessel party who: (1) In an arm's—length transaction...
50 CFR 600.1000 - Definitions.
Code of Federal Regulations, 2012 CFR
2012-10-01
....1009. Borrower means, individually and collectively, each post-reduction fishing permit holder and/or... “ex-vessel value” as used in section 312 of the Magnuson Act. Deposit principal means all collected... reduction loan. Fish buyer means the first ex-vessel party who: (1) In an arm's—length transaction...
Functional Outcomes 18 Months After Total and Midarm Transplantation: A Case Report.
Iglesias, M; Ramírez-Berumen, M; Butrón, P; Alberú-Gómez, J; Salazar-Hernández, F; Macias-Gallardo, J; Leal-Villalpando, R P; Zamudio-Bautista, J; Acosta, V; Jauregui, L; Hernández-Campos, A; Espinosa-Cruz, V; Vázquez-Lamadrid, J; González-Sánchez, J; Cuellar-Rodriguez, J; Sierra-Madero, J G; Gaytan-Cervantes, R; Contreras-Barbosa, S; Navarro-Lara, A; Guzman-Gonzalez, J; Domínguez-Cherit, J; Vilatoba, M; Toussaint-Caire, S; Vega-Boada, F; Gómez-Pérez, F J; Mayorquin-Ruiz, M
2018-04-01
The function reported after arm transplantation is deemed beneficial relative to the marked disability that upper arm amputation causes. We report a 51-year-old man with a Disabilities of the Arm, Shoulder and Hand (DASH) score of 75.83 who underwent bilateral arm transplantation in October 2015. The right arm was transplanted at the glenohumeral joint level, including transplantation of the humeral head, joint capsule, and rotator cuff ligaments and tendons. Additionally, neurorrhaphies were performed at the origin of the terminal branches of the brachial plexus, including the axillary and musculocutaneous nerves. Therefore, this was considered a total arm transplantation. The left arm was transplanted at the transhumeral level, with complete transplantation of the biceps and triceps brachii, and terminolateral neurorrhaphy of the donor musculocutaneous nerve to the receptor radial nerve. A maintenance triple immunosuppression scheme was administered, with tacrolimus levels kept at 10 ng/mL. At 18 months post-transplantation, the intrinsic musculature in the left hand showed electrical registry, DASH score was 67.5, Carroll test score was 28 in both extremities, Hand Transplant Score System was 67.5 in the right extremity and 77.5 in the left extremity, and Short Form-36 score was 96.1. The patient was healthy, with restored body integrity. He could lift medium-sized weightless objects, eat and go to the bathroom by himself, drink liquids with bimanual grasp, swim, dress almost independently, and drive. The functional evolution of the patient was similar to previously reported transplanted arms, even though the right arm transplant involved the glenohumeral joint and axillary and musculocutaneous nerve repair. Copyright © 2017 Elsevier Inc. All rights reserved.
Arm swing as a potential new prodromal marker of Parkinson's disease.
Mirelman, Anat; Bernad-Elazari, Hagar; Thaler, Avner; Giladi-Yacobi, Eytan; Gurevich, Tanya; Gana-Weisz, Mali; Saunders-Pullman, Rachel; Raymond, Deborah; Doan, Nancy; Bressman, Susan B; Marder, Karen S; Alcalay, Roy N; Rao, Ashwini K; Berg, Daniela; Brockmann, Kathrin; Aasly, Jan; Waro, Bjørg Johanne; Tolosa, Eduardo; Vilas, Dolores; Pont-Sunyer, Claustre; Orr-Urtreger, Avi; Hausdorff, Jeffrey M; Giladi, Nir
2016-10-01
Reduced arm swing is a well-known clinical feature of Parkinson's disease (PD), often observed early in the course of the disease. We hypothesized that subtle changes in arm swing and axial rotation may also be detectable in the prodromal phase. The purpose of this study was to evaluate the relationship between the LRRK2-G2019S mutation, arm swing, and axial rotation in healthy nonmanifesting carriers and noncarriers of the G2019S mutation and in patients with PD. A total of 380 participants (186 healthy nonmanifesting controls and 194 PD patients) from 6 clinical sites underwent gait analysis while wearing synchronized 3-axis body-fixed sensors on the lower back and bilateral wrists. Participants walked for 1 minute under the following 2 conditions: (1) usual walking and (2) dual-task walking. Arm swing amplitudes, asymmetry, variability, and smoothness were calculated for both arms along with measures of axial rotation. A total of 122 nonmanifesting participants and 67 PD patients were carriers of the G2019S mutation. Nonmanifesting mutation carriers walked with greater arm swing asymmetry and variability and lower axial rotation smoothness under the dual task condition when compared with noncarriers (P < .04). In the nonmanifesting mutation carriers, arm swing asymmetry was associated with gait variability under dual task (P = .003). PD carriers showed greater asymmetry and variability of movement than PD noncarriers, even after controlling for disease severity (P < .009). The G2019S mutation is associated with increased asymmetry and variability among nonmanifesting participants and patients with PD. Prospective studies should determine if arm swing asymmetry and axial rotation smoothness may be used as motor markers of prodromal PD. © 2016 International Parkinson and Movement Disorder Society. © 2016 International Parkinson and Movement Disorder Society.
Zhao, Zhihui; Liu, Zhen; Hu, Zongshan; Tseng, Changchun; Li, Jie; Pan, Wei; Qiu, Yong; Zhu, Zezhang
2018-03-16
The purpose of this study was to analyze the occurrence of PE after intra-operative O-arm navigation-assisted surgery and determine whether the post-operative PE incidence could be decreased by using O-arm navigation as compared to conventional free-hand technique. A cohort of 27 patients with spinal deformity who were operated upon with an O-arm navigated system (group A) between 2013 and 2016 were enrolled in the study. A total of 27 curve-matched patients treated by conventional free-hand technique were included as the control group (group B). Whole spine posterior-anterior and lateral radiographs, and CT scans were taken pre and post-operation. Radiologic parameters and volume of PE were measured and compared between the two groups. There were no significant differences in age, Cobb angle, and sagittal contour between the two groups pre-operatively. The mean total volume of post-operative PE was significantly larger in the free-hand group (p < 0.001). In the O-arm group, 59 malpositioned screws were identified in 22 patients. In the free-hand group, 88 malpositioned screws were found among 26 patients. The screw perforation rate was higher in the free-hand group than in the O-arm group (p = 0.007). In the O-arm group, the mean volume of PE was significantly larger among patients with malpositioned screws than those without malpositioned screws (p < 0.001), as well as in the free-hand group. The volume of PE after correction surgery can be significantly decreased by application of O-arm navigation system as compared to conventional free-hand technique. We ascribed the improvement to the accuracy of screw implantation navigated by O-arm.
Datta Banik, Sudip
2011-11-01
This study aimed to understand the interrelationship between height and arm span and also to estimate nutritional status from arm span. In an anthropometric survey conducted among the Dhimals (227 males and 223 females, total = 450) of Naxalbari in West Bengal, India, measurements were recorded in age groups ranging between 10-59 years. Males were taller and had longer arm spans than females. The height-arm span ratio was 0.98-0.99, indicating height to be slightly less than arm span in both sexes. High correlation between these two dimensions was also observed. Regression equations provided a good model for estimating height from arm span (predictor). In all age groups of both sexes, values of standardized coefficient beta exhibited high significance (p ( 0.001). Residuals showed no pattern and were random. No significant difference between height-based body mass index or BMI (body weight/height(2)) and estimated arm span-based BMI (body weight/arm span(2)) was observed in any age group. Arm span was found to be an effective surrogate measure for BMI.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wolfson, Aaron H., E-mail: awolfson@med.miami.edu; Bae, Kyounghwa; Komaki, Ritsuko
2011-09-01
Purpose: To determine the effect of dose and fractionation schedule of prophylactic cranial irradiation (PCI) on the incidence of chronic neurotoxicity (CNt) and changes in quality of life for selected patients with limited-disease small-cell lung cancer (LD SCLC). Methods and Materials: Patients with LD SCLC who achieved a complete response after chemotherapy and thoracic irradiation were eligible for randomization to undergo PCI to a total dose of 25 Gy in 10 daily fractions (Arm 1) vs. the experimental cohort of 36 Gy. Those receiving 36 Gy underwent a secondary randomization between daily 18 fractions (Arm 2) and twice-daily 24 fractionsmore » (Arm 3). Enrolled patients participated in baseline and follow-up neuropsychological test batteries along with quality-of-life assessments. Results: A total of 265 patients were accrued, with 131 in Arm 1, 67 in Arm 2, and 66 in Arm 3 being eligible. There are 112 patients (42.2%) alive with 25.3 months of median follow-up. There were no significant baseline differences among groups regarding quality-of-life measures and one of the neuropsychological tests, namely the Hopkins Verbal Learning Test. However, at 12 months after PCI there was a significant increase in the occurrence of CNt in the 36-Gy cohort (p = 0.02). Logistic regression analysis revealed increasing age to be the most significant predictor of CNt (p = 0.005). Conclusions: Because of the increased risk of developing CNt in study patients with 36 Gy, a total PCI dose of 25 Gy remains the standard of care for patients with LD SCLC attaining a complete response to initial chemoradiation.« less
Chromosomal intrachanges induced by swift iron ions
NASA Astrophysics Data System (ADS)
Horstmann, M.; Durante, M.; Johannes, C.; Obe, G.
We measured the induction of aberrations in human chromosome 5 by iron ions using the novel technique of multicolor banding in situ hybridization (mBAND). Human lymphocytes isolated from whole blood were exposed in vitro to 500 MeV/n (LET=200 keV/μ m, doses 1 or 4 Gy) 56Fe nuclei at the HIMAC accelerator in Chiba (Japan). Chromosomes were prematurely condensed by calyculin A after 48 h in culture, and slides were painted by mBAND (MetaSystems). We found a frequency of 0.11 and 0.57 residual breakpoints per chromosome 5 after 1 Gy and 4 Gy Fe-ions, respectively. The distribution per unit length were similar in the p- and q-arm of chromosome 5, and >50% of the observed fragments measured <30% of the whole chromosome length. Only small fragments (<40% of the chromosome size) were involved in intra-chromosomal exchanges (interstitial deletions or inversions), whereas fragments up to 75% of the whole chromosome 5 were found in inter-chromosomal exchanges. We measured more inter-changes than intra-changes, and more intra-arm than inter-arm exchanges at both doses. No significant differences in the ratios of these aberrations were detected with respect to X-rays. On the other hand, Fe-ions induced a significantly higher fraction of complex-type exchanges when compared to sparsely ionizing radiation. Work supported by DLR, BMBF, INTAS and NIRS-HIMAC.
Kim, Chun-Ja; Park, Eunyoung; Schlenk, Elizabeth A; Kim, Moonsun; Kim, Dae Jung
2016-04-01
The purpose of the study was to examine the reliability and validity of the Adherence to Refills and Medications Scale-Korean (ARMS-K) among Korean adults with type 2 diabetes. The Korean translated ARMS-K was back-translated to ensure translation equivalency. A cross-sectional survey was used to evaluate the psychometric properties with exploratory factor analysis for validity and Cronbach's alpha coefficients for reliability. The factor analysis of construct validity identified 3 dimensions of the ARMS-K, explaining 54.7% of the total variance. The internal consistency reliability for the total instrument was acceptable with a Cronbach's alpha of .801. There was good correlation between the ARMS-K and 8-item Morisky Medication Adherence Scale-Korean version (r = -0.698), indicating that these scales measure theoretically related constructs as evidence of convergent validity. As evidence of known groups validity, there was a significant association between the ARMS-K score and glycemic control (P = .048), indicating that the good glycemic controlled group was more likely to have a higher rate of adherence to refills and medications than the poor glycemic controlled group. These results support the cross-cultural applicability of the concepts underlying the ARMS-K. The ARMS-K can be used not only to assess adherence to refills and medications in Koreans with diabetes but also to examine the potential role of adherence to refills and medications in enhanced glycemic control of people with diabetes in a variety of clinical settings. © 2016 The Author(s).
Achromatic self-referencing interferometer
Feldman, Mark
1994-01-01
A self-referencing Mach-Zehnder interferometer for accurately measuring laser wavefronts over a broad wavelength range (for example, 600 nm to 900 nm). The apparatus directs a reference portion of an input beam to a reference arm and a measurement portion of the input beam to a measurement arm, recombines the output beams from the reference and measurement arms, and registers the resulting interference pattern ("first" interferogram) at a first detector. Optionally, subportions of the measurement portion are diverted to second and third detectors, which respectively register intensity and interferogram signals which can be processed to reduce the first interferogram's sensitivity to input noise. The reference arm includes a spatial filter producing a high quality spherical beam from the reference portion, a tilted wedge plate compensating for off-axis aberrations in the spatial filter output, and mirror collimating the radiation transmitted through the tilted wedge plate. The apparatus includes a thermally and mechanically stable baseplate which supports all reference arm optics, or at least the spatial filter, tilted wedge plate, and the collimator. The tilted wedge plate is mounted adjustably with respect to the spatial filter and collimator, so that it can be maintained in an orientation in which it does not introduce significant wave front errors into the beam propagating through the reference arm. The apparatus is polarization insensitive and has an equal path length configuration enabling measurement of radiation from broadband as well as closely spaced laser line sources.
Robots testing robots: ALAN-Arm, a humanoid arm for the testing of robotic rehabilitation systems.
Brookes, Jack; Kuznecovs, Maksims; Kanakis, Menelaos; Grigals, Arturs; Narvidas, Mazvydas; Gallagher, Justin; Levesley, Martin
2017-07-01
Robotics is increasing in popularity as a method of providing rich, personalized and cost-effective physiotherapy to individuals with some degree of upper limb paralysis, such as those who have suffered a stroke. These robotic rehabilitation systems are often high powered, and exoskeletal systems can attach to the person in a restrictive manner. Therefore, ensuring the mechanical safety of these devices before they come in contact with individuals is a priority. Additionally, rehabilitation systems may use novel sensor systems to measure current arm position. Used to capture and assess patient movements, these first need to be verified for accuracy by an external system. We present the ALAN-Arm, a humanoid robotic arm designed to be used for both accuracy benchmarking and safety testing of robotic rehabilitation systems. The system can be attached to a rehabilitation device and then replay generated or human movement trajectories, as well as autonomously play rehabilitation games or activities. Tests of the ALAN-Arm indicated it could recreate the path of a generated slow movement path with a maximum error of 14.2mm (mean = 5.8mm) and perform cyclic movements up to 0.6Hz with low gain (<1.5dB). Replaying human data trajectories showed the ability to largely preserve human movement characteristics with slightly higher path length and lower normalised jerk.
Margheri, Laura; Mazzolai, Barbara; Cianchetti, Matteo; Dario, Paolo; Laschi, Cecilia
2009-01-01
This work illustrates new tools and methods for an in vivo and direct, but non-invasive, measurement of an octopus arm mechanical properties. The active elongation (longitudinal stretch) and the pulling force capability are measured on a specimen of Octopus vulgaris in order to quantitatively characterize the parameters describing the arm mechanics, for biomimetic design purposes. The novel approach consists of observing and measuring a living octopus with minimally invasive methods, which allow the animal to move with its complete ability. All tools are conceived in order to create a collaborative interaction with the animal for the acquisition of active measures. The data analysis is executed taking into account the presence of an intrinsic error due to the mobility of the subject and the aquatic environment. Using a system of two synchronized high-speed high-resolution cameras and purpose-made instruments, the maximum elongation of an arm and its rest length (when all muscles fibres are relaxed during propulsion movement) are measured and compared to define the longitudinal stretch, with the impressive average result of 194%. With a similar setup integrated with a force sensor, the pulling force capability is measured as a function of grasp point position along the arm. The measured parameters are used as real specifications for the design of an octopus-like arm with a biomimetic approach.
Ahn, Ki-Yong; Hur, Hyuk; Kim, Dong-Hyun; Min, Jihee; Jeong, Duck Hyoun; Chu, Sang Hui; Lee, Ji Won; Ligibel, Jennifer A; Meyerhardt, Jeffrey A; Jones, Lee W; Jeon, Justin Y; Kim, Nam Kyu
2013-05-01
This study aimed to examine the effects of a postsurgical, inpatient exercise program on postoperative recovery in operable colon cancer patients We conducted the randomized controlled trial with two arms: postoperative exercise vs. usual care. Patients with stages I-III colon cancer who underwent colectomy between January and December 2011 from the Colorectal Cancer Clinic, were recruited for the study. Subjects in the intervention group participated in the postoperative inpatient exercise program consisted of twice daily exercise, including stretching, core, balance, and low-intensity resistance exercises. The usual care group was not prescribed a structured exercise program. The primary endpoint was the length of hospital stay. Secondary endpoints were time to flatus, time to first liquid diet, anthropometric measurements, and physical function measurements. A total of 31 (86.1 %) patients completed the trial, with adherence to exercise interventions at 84.5 %. The mean length of hospital stay was 7.82 ± 1.07 days in the exercise group compared with 9.86 ± 2.66 days in usual care (mean difference, 2.03 days; 95 % confidence interval (CI), -3.47 to -0.60 days; p = 0.005) in per-protocol analysis. The mean time to flatus was 52.18 ± 21.55 h in the exercise group compared with 71.86 ± 29.2 h in the usual care group (mean difference, 19.69 h; 95 % CI, -38.33 to -1.04 h; p = 0.036). Low-to-moderate-intensity postsurgical exercise reduces length of hospital stay and improves bowel motility after colectomy procedure in patients with stages I-III colon cancer.
Kuznetsova, Olga M; Tymofyeyev, Yevgen
2014-04-30
In open-label studies, partial predictability of permuted block randomization provides potential for selection bias. To lessen the selection bias in two-arm studies with equal allocation, a number of allocation procedures that limit the imbalance in treatment totals at a pre-specified level but do not require the exact balance at the ends of the blocks were developed. In studies with unequal allocation, however, the task of designing a randomization procedure that sets a pre-specified limit on imbalance in group totals is not resolved. Existing allocation procedures either do not preserve the allocation ratio at every allocation or do not include all allocation sequences that comply with the pre-specified imbalance threshold. Kuznetsova and Tymofyeyev described the brick tunnel randomization for studies with unequal allocation that preserves the allocation ratio at every step and, in the two-arm case, includes all sequences that satisfy the smallest possible imbalance threshold. This article introduces wide brick tunnel randomization for studies with unequal allocation that allows all allocation sequences with imbalance not exceeding any pre-specified threshold while preserving the allocation ratio at every step. In open-label studies, allowing a larger imbalance in treatment totals lowers selection bias because of the predictability of treatment assignments. The applications of the technique in two-arm and multi-arm open-label studies with unequal allocation are described. Copyright © 2013 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Sugandi, Gandi; Mambu, Grace A.; Mulyadi, Dadang; Mulyana, Edi
2017-07-01
Planar spring as a mechanical resonator is very important in designing an electrodynamic vibration energy harvesting application (EVEH) to generate output power with high efficiency. Generally, component of the mechanical resonator is a cantilever beam that is designed using one cantilever with an inertial mass placed cantilever tip. In this study, a planar spring which has four arms cantilever beam was designed and fabricated using an extra-thin FR4-PCB material with a total thickness of 130 µm. There are four types of planar spring that were designed and fabricated in this research to produce resonant frequencies at about 30, 40, 50 and 60 Hz with 1 mm width cantilever arm and various length of 13.5, 11.2, 9.8 and 8.7 mm, respectively. FR4 resonator is fabricated using technology LASER-cutting in order to obtain results precisely. The resonant frequency generated by the mechanical resonator is characterized using vibrator system with certain acceleration. The resonant frequency of the planar spring was obtained at a frequency where the maximum induced voltage occurs. The resonant frequency generated by each type of planar spring was obtained at 24.81, 34.24, 40.2, and 46.8 Hz with three conditions of acceleration of 0.02, 0.06, and 0,1g (g=9.8 m/s2).
30 CFR 206.458 - Determination of washing allowances.
Code of Federal Regulations, 2010 CFR
2010-07-01
... MANAGEMENT PRODUCT VALUATION Indian Coal § 206.458 Determination of washing allowances. (a) Arm's-length... allowance shall be the reasonable actual costs incurred by the lessee for washing the coal under that... deduction may be taken, the lessee must submit a completed page one of Form MMS-4292, Coal Washing Allowance...
Curriculum Theory, Curriculum Policy and the Problem of Ill-Disciplined Thinking
ERIC Educational Resources Information Center
Harris, Richard; Burn, Katharine
2011-01-01
This paper examines the implications of policy fracture and arms length governance within the decision-making processes currently shaping curriculum design within the English education system. In particular, it argues that an unresolved "ideological fracture" at the government level has been passed down to school leaders whose response…
ERIC Educational Resources Information Center
Jacoby, Russell
2008-01-01
Earlier 20th-century thinkers like Lewis Mumford and Edmund Wilson kept the university and its apparatus at arm's length. Indeed, they often disdained it. They oriented themselves toward an educated public, and, as a result, they developed a straightforward prose and gained a nonprofessional audience. As his reputation grew, Wilson printed up a…
ERIC Educational Resources Information Center
Szekely, George
2010-01-01
As soon as they graduate from arm-length viewing in shopping-cart seats, children take off to adventure in aisles, touching just about everything. Kids will pocket fallen signs and lug unusual, empty shelves and packaging materials in hopes of taking them home. Kids recognize and compliment supermarket artists--stock clerks who create container…
A multivalent three-point linkage analysis model of autotetraploids
USDA-ARS?s Scientific Manuscript database
A cytogenetic study was conducted on a dihaploid individual (2n'='2X'='18) of switchgrass to establish a chromosome karyotype. Size differences, condensation patterns, and arm-length ratios were used as identifying features and fluorescence in-situ hybridization (FISH) assigned 5S and 45S rDNA loci...
ERIC Educational Resources Information Center
Ulbricht, Kurt; Zimmermann, Peter
1981-01-01
Problems encountered in testing in aerospace engineering courses in an accelerated technical program of a German military university are outlined. Four common grading procedures are compared, and the optimum length of written tests is discussed. (MSE)
Hong-Ou-Mandel interferometer with cavities: Theory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olindo, C.; Sagioro, M. A.; Monken, C. H.
2006-04-15
We study the number of coincidences in a Hong-Ou-Mandel interferometer exit whose arms have been supplemented with the addition of one or two optical cavities. The fourth-order correlation function at the beam splitter exit is calculated. In the regime where the cavities lengths are larger than the one-photon coherence length, photon coalescence and anticoalescence interference is observed. Feynman's path diagrams for the indistinguishable processes that lead to quantum interference are presented. The construction of an optical XOR gate is discussed as an application for the Hong-Ou-Mandel interferometer with two cavities.
Estimation of Gestational Age, Using Neonatal Anthropometry: A Cross-sectional Study in India
Thawani, Rajat; Faridi, M.M.A.; Arora, Shilpa Khanna; Kumar, Rajeev
2013-01-01
Prematurity is a significant contributor to neonatal mortality in India. Conventionally, assessment of gestational age of newborns is based on New Ballard Technique, for which a paediatric specialist is needed. Anthropometry of the newborn, especially birthweight, has been used in the past to predict the gestational age of the neonate in peripheral health facilities where a trained paediatrician is often not available. We aimed to determine if neonatal anthropometric parameters, viz. birthweight, crown heel-length, head-circumference, mid-upper arm-circumference, lower segment-length, foot-length, umbilical nipple distance, calf-circumference, intermammary distance, and hand-length, can reliably predict the gestational age. The study also aimed to derive an equation for the same. We also assessed if these neonatal anthropometric parameters had a better prediction of gestational age when used in combination compared to individual parameters. We evaluated 1,000 newborns in a cross-sectional study conducted in Guru Teg Bahadur Hospital in Delhi. Detailed anthropometric estimation of the neonates was done within 48 hours after birth, using standard techniques. Gestational age was estimated using New Ballard Scoring. Out of 1,250 consecutive neonates, 1,000 were included in the study. Of them, 800 randomly-selected newborns were used in devising the model, and the remaining 200 newborns were used in validating the final model. Quadratic regression analysis using stepwise selection was used in building the predictive model. Birthweight (R=0.72), head-circumference (R=0.60), and mid-upper arm-circumference (R=0.67) were found highly correlated with gestation. The final equation to assess gestational age was as follows: Gestational age (weeks)=5.437×W–0.781×W2+2.815×HC–0.041×HC2+0.285×MUAC–22.745 where W=Weight, HC=Head-circumference and MUAC=Mid-upper arm-circumference; Adjusted R=0.76. On validation, the predictability of this equation is 46% (±1 week), 75.5% (+2 weeks), and 91.5% (+3 weeks). This mathematical model may be used in identifying preterm neonates. PMID:24592594
Ricke, Jens; Bulla, Karsten; Kolligs, Frank; Peck-Radosavljevic, Markus; Reimer, Peter; Sangro, Bruno; Schott, Eckart; Schütte, Kerstin; Verslype, Chris; Walecki, Jerzy; Malfertheiner, Peter
2015-02-01
The benefits of combined systemic and liver-directed treatments in inoperable intermediate- or advanced-stage hepatocellular carcinoma (HCC) have yet to be defined. This article presents the planned safety analyses for the first 40 patients randomized to radioembolization with yttrium-90 ((90) Y) resin microspheres followed by sorafenib (n = 20) or sorafenib only (n = 20) in the SORAMIC study. Patients identified for palliative treatment who were poor candidates for transarterial (chemo)embolization (including those failing TACE) with preserved liver function (Child-Pugh ≤B7) and ECOG performance status <2 were screened. Radioembolization was administered using a sequential lobar approach. On day 3 after the last radioembolization procedure, sorafenib 200 mg twice daily was initiated escalating to 400 mg twice daily 1 week later; a matching sorafenib dose schedule was initiated in the control arm. Patients were followed up for a median of 8.3 months. Median total implanted activity of (90) Y was 1.87 (range: 0.54-2.35) GBq. Patients received a similar intensity and duration of sorafenib in the combination-treatment arm (median daily dose 614 mg over 8.5 months) and control arm (557 mg over 9.6 months). The incidence of total (196 vs. 222) and grade ≥3 (43 vs. 47) adverse events was similar in combination-treatment arm and control arm respectively (P > 0.05). No significant differences in the number of total or grade 3/4 toxicities were recorded for: total bilirubin, albumin, liver enzymes, ascites, Child-Pugh, fatigue, hand-foot skin reaction, blood pressure or diarrhoea. Radioembolization followed by sorafenib appears to be as well tolerated as sorafenib alone. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Emond, Jennifer A; Patterson, Ruth E; Natarajan, Loki; Laughlin, Gail A; Gold, Ellen B; Pierce, John P
2011-05-01
We examined if the reduced risk of breast cancer events seen among women without baseline hot flash symptoms in the Women's Healthy Eating and Living (WHEL) dietary intervention trial was related to changes in sex hormone concentrations. Baseline and year one concentrations of total and bioavailable estradiol, and testosterone and sex hormone-binding globulin (SHBG) were compared by intervention arm among 447 postmenopausal women without hot flashes. Cox proportional hazard models tested interaction terms between study arm and baseline hormone concentrations adjusted for study site, antiestrogen use, positive nodes, tumor size, oophorectomy status, and hormone replacement therapy use. Sex hormone concentrations did not differ by study arm at baseline nor at year one. Twenty-two (9.8%) events occurred in the intervention arm versus 42 (18.9%) in the comparison arm (P = 0.009). Baseline bioavailable testosterone was significantly, positively associated with additional events (HR 1.69, 95% CI: 1.00-2.84; P = 0.049). There were significant interactions between the intervention and total (P = 0.015), and bioavailable (P = 0.050) testosterone: the intervention was more protective among participants with higher baseline total (HR 0.3, 95% CI: 0.2-0.7) or bioavailable (HR 0.4, 95% CI: 0.2-0.7) testosterone than for participants with lower baseline total (HR 0.8, 95% CI: 0.4-1.5) or bioavailable (HR 0.8, 95% CI: 0.4-1.5) testosterone. No significant effects were seen for estradiol or SHBG. The WHEL dietary intervention may have modified other risk factors of recurrence correlated with testosterone. Sex hormones should be considered as part of a larger biological system related to the risk of breast cancer recurrence. ©2011 AACR.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Du, Xinyu; Xu, Ye; Yang, Ji
The lack of arm tracers, especially remote tracers, is one of the most difficult problems preventing us from studying the structure of the Milky Way. Fortunately, with its high-sensitivity CO survey, the Milky Way Imaging Scroll Painting (MWISP) project offers such an opportunity. Since completing about one-third of its mission, an area of l = [100, 150]°, b = [−3, 5]° has nearly been covered. The Outer arm of the Milky Way first clearly revealed its shape in the second galactic quadrant in the form of molecular gas—this is the first time that the Outer arm has been reported inmore » such a large-scale mapping of molecular gas. Using the 115 GHz {sup 12}CO(1–0) data of MWISP at the LSR velocity ≃[−100, −60] km s{sup −1} and in the area mentioned above, we have detected 481 molecular clouds in total, and among them 332 (about 69%) are newly detected and 457 probably belong to the Outer arm. The total mass of the detected Outer arm clouds is ∼3.1 × 10{sup 6} M {sub ⊙}. Assuming that the spiral arm is a logarithmic spiral, the pitch angle is fitted as ∼13.°1. Besides combining both the CO data from MWISP and the 21 cm H i data from the Canadian Galactic Plane Survey (CGPS), the gas distribution, warp, and thickness of the Outer arm are also studied.« less
Reduced-dose C-arm computed tomography applications at a pediatric institution.
Acord, Michael; Shellikeri, Sphoorti; Vatsky, Seth; Srinivasan, Abhay; Krishnamurthy, Ganesh; Keller, Marc S; Cahill, Anne Marie
2017-12-01
Reduced-dose C-arm computed tomography (CT) uses flat-panel detectors to acquire real-time 3-D images in the interventional radiology suite to assist with anatomical localization and procedure planning. To describe dose-reduction techniques for C-arm CT at a pediatric institution and to provide guidance for implementation. We conducted a 5-year retrospective study on procedures using an institution-specific reduced-dose protocol: 5 or 8 s Dyna Rotation, 248/396 projection images/acquisition and 0.1-0.17 μGy/projection dose at the detector with 0.3/0.6/0.9-mm copper (Cu) filtration. We categorized cases by procedure type and average patient age and calculated C-arm CT and total dose area product (DAP). Two hundred twenty-two C-arm CT-guided procedures were performed with a dose-reduction protocol. The most common procedures were temporomandibular and sacroiliac joint injections (48.6%) and sclerotherapy (34.2%). C-arm CT was utilized in cases of difficult percutaneous access in less common applications such as cecostomy and gastrostomy placement, foreign body retrieval and thoracentesis. C-arm CT accounted for between 9.9% and 80.7% of the total procedural DAP. Dose-reducing techniques can preserve image quality for intervention while reducing radiation exposure to the child. This technology has multiple applications within pediatric interventional radiology and can be considered as an adjunctive imaging tool in a variety of procedures, particularly when percutaneous access is challenging despite routine fluoroscopic or ultrasound guidance.
Yılmaz, Hasan; Yavuz, Ufuk; Üstüner, Murat; Çiftçi, Seyfettin; Yaşar, Hikmet; Müezzinoğlu, Bahar; Uslubaş, Ali Kemal; Dillioğlugil, Özdal
2017-01-01
Objective Only a few papers in the literature aimed to evaluate biopsy core lengths. Additionally, studies evaluated the core length with different approaches. We aimed to determine whether prostate cancer (PCa) detection is affected from core lengths according to three different approaches in a large standard cohort and compare our cut-off values with the published cut-offs. Material and methods We retrospectively analyzed 1,523 initial consecutive transrectal ultrasound-guided 12-core prostate biopsies. Biopsies were evaluated with respect to total core length (total length of each patients’ core) average core length (total core length divided by total number of cores in each patient), and mean core length (mean length of all cores pooled), and compared our cut-off values with the published cut-offs. The prostate volumes were categorized into four groups (<30, 30–59.99, 60–119.99, ≥120 cm3) and PCa detection rates in these categories were examined. Results PCa was found in 41.5% patients. There was no difference between benign and malignant mean core lengths of the pooled cores (p>0.05). Total core length and average core length were not significantly associated with PCa in multivariate logistic regression analyses (p>0.05). The core lengths (mean, average and total core lengths) increased (p<0.001) and PCa rates decreased (p<0.001) steadily with increasing prostate volume categories. PCa percentages decreased in all categories above the utilized cut-offs for mean (p>0.05), average (p<0.05), and total core lengths (p>0.05). Conclusion There was no difference between mean core lengths of benign and malignant cores. Total core length and average core length were not significantly associated with PCa. Contrary to the cut-offs used for mean and average core lengths in the published studies, PCa rates decrease as these core lengths increase. Larger studies are necessary for the determination and acceptance of accurate cut-offs. PMID:28861301
Valdes, Carla; Black, Frank J; Stringham, Blair; Collins, Jeffrey N; Goodman, James R; Saxton, Heidi J; Mansfield, Christopher R; Schmidt, Joshua N; Yang, Shu; Johnson, William P
2017-05-02
Measurements of chemical and physical parameters made before and after sealing of culverts in the railroad causeway spanning the Great Salt Lake in late 2013 documented dramatic alterations in the system in response to the elimination of flow between the Great Salt Lake's north and south arms. The flow of denser, more-saline water through the culverts from the north arm (Gunnison Bay) to the south arm (Gilbert Bay) previously drove the perennial stratification of the south arm and the existence of oxic shallow brine and anoxic deep brine layers. Closure of the causeway culverts occurred concurrently with a multiyear drought that resulted in a decrease in the lake elevation and a concomitant increase in top-down erosion of the upper surface of the deep brine layer by wind-forced mixing. The combination of these events resulted in the replacement of the formerly stratified water column in the south arm with one that was vertically homogeneous and oxic. Total mercury concentrations in the deep waters of the south arm decreased by approximately 81% and methylmercury concentrations in deep waters decreased by roughly 86% due to destratification. Methylmercury concentrations decreased by 77% in underlying surficial sediment, whereas there was no change observed in total mercury. The dramatic mercury loss from deep waters and methylmercury loss from underlying sediment in response to causeway sealing provides new understanding of the potential role of the deep brine layer in the accumulation and persistence of methylmercury in the Great Salt Lake. Additional mercury measurements in biota appear to contradict the previously implied connection between elevated methylmercury concentrations in the deep brine layer and elevated mercury in avian species reported prior to causeway sealing.
The Perseus arm in the anticenter direction
NASA Astrophysics Data System (ADS)
Monguió, M.; Grosbøl, P.; Figueras, F.
2015-05-01
The stellar overdensity due to the Perseus arm has been detected in the anticenter direction through individual field stars. For that purpose, a Str&{uml;o}mgren photometric survey covering 16° ^2 was developed with the Wide Field Camera at the Isaac Newton Telescope. This photometry allowed us to compute individual physical parameters for these stars using a new method based on atmospheric models and evolutionary tracks. The analysis of the surface density as a function of distance for intermediate young stars in this survey allowed us to detect an overdensity at 1.6±0.2 kpc from the Sun, that can be associated with the Perseus arm, with a surface density amplitude of ˜14%. The significance of the detection is above 4σ for all the cases. The fit for the radial scale length of the Galactic disk provided values in the range [2.9,3.5] kpc for the population of the B4-A1 stars. We also analyzed the interstellar visual absorption distribution, and its variation as a function of distance is coherent with a dust layer before the Perseus arm location.
Golczyk, Hieronim; Hasterok, Robert; Szklarczyk, Marek
2010-12-01
High- and low-stringency FISH and base-specific fluorescence were performed on the permanent translocation heterozygote Rhoeo spathacea (2n = 12). Our results indicate that 45S rDNA arrays, rDNA-related sequences and other GC-rich DNA fraction(s) are located within the pericentromeric regions of all twelve chromosomes, usually colocalizing with the chromomycin A(3)-positive bands. Homogenization of the pericentromeric regions appears to result from the concerted spread of GC-rich sequences, with differential amplification likely. We found new 5S rDNA patterns, which suggest a variability in the breakpoints and in the consequent chromosome reorganizations. It was found that the large 5S rDNA locus residing on each of the 8E and 9E arms consisted of two smaller loci. On each of the two chromosome arms 3b and 4b, in addition to the major subtelomeric 5S rDNA locus, a new minor locus was found interstitially about 40% along the arm length. The arrangement of cytotogenetic landmarks and chromosome arm measurements are discussed with regard to genome repatterning in Rhoeo.
Swing arm profilometer: analytical solutions of misalignment errors for testing axisymmetric optics
NASA Astrophysics Data System (ADS)
Xiong, Ling; Luo, Xiao; Liu, Zhenyu; Wang, Xiaokun; Hu, Haixiang; Zhang, Feng; Zheng, Ligong; Zhang, Xuejun
2016-07-01
The swing arm profilometer (SAP) has been playing a very important role in testing large aspheric optics. As one of most significant error sources that affects the test accuracy, misalignment error leads to low-order errors such as aspherical aberrations and coma apart from power. In order to analyze the effect of misalignment errors, the relation between alignment parameters and test results of axisymmetric optics is presented. Analytical solutions of SAP system errors from tested mirror misalignment, arm length L deviation, tilt-angle θ deviation, air-table spin error, and air-table misalignment are derived, respectively; and misalignment tolerance is given to guide surface measurement. In addition, experiments on a 2-m diameter parabolic mirror are demonstrated to verify the model; according to the error budget, we achieve the SAP test for low-order errors except power with accuracy of 0.1 μm root-mean-square.
International Space Station (ISS)
2002-06-01
Pictured here is the Space Shuttle Orbiter Endeavour, STS-111 mission insignia. The International Space Station (ISS) recieved a new crew, Expedition Five, replacing Expedition Four after a record-setting 196 days in space, when STS-111 visited in June 2002. Three spacewalks enabled the STS-111 crew to accomplish additional mission objectives: the delivery and installation of a new platform for the ISS robotic arm, the Mobile Base System (MBS) which is an important part of the Station's Mobile Servicing System allowing the robotic arm to travel the length of the Station; the replacement of a wrist roll joint on the Station's robotic arm; and unloading supplies and science experiments from the Leonardo Multi-Purpose Logistics Module, which made its third trip to the orbital outpost. The STS-111 mission, the 14th Shuttle mission to visit the ISS, was launched on June 5, 2002 and landed June 19, 2002.
The role of ecology, neutral processes and antagonistic coevolution in an apparent sexual arms race.
Perry, Jennifer C; Garroway, Colin J; Rowe, Locke
2017-09-01
Some of the strongest examples of a sexual 'arms race' come from observations of correlated evolution in sexually antagonistic traits among populations. However, it remains unclear whether these cases truly represent sexually antagonistic coevolution; alternatively, ecological or neutral processes might also drive correlated evolution. To investigate these alternatives, we evaluated the contributions of intersex genetic correlations, ecological context, neutral genetic divergence and sexual coevolution in the correlated evolution of antagonistic traits among populations of Gerris incognitus water striders. We could not detect intersex genetic correlations for these sexually antagonistic traits. Ecological variation was related to population variation in the key female antagonistic trait (spine length, a defence against males), as well as body size. Nevertheless, population covariation between sexually antagonistic traits remained substantial and significant even after accounting for all of these processes. Our results therefore provide strong evidence for a contemporary sexual arms race. © 2017 John Wiley & Sons Ltd/CNRS.
Honda, Miwako; Ishisaka, Michiyo; Ishizuka, Naoki; Kimura, Satoshi; Oka, Shinichi
2011-01-01
The side-effects of anti-retroviral drugs are different between Japanese and Caucasian patients. Severe central nerve system (CNS) side-effects to efavirenz and low rate of hypersensitivity against abacavir characterize the Japanese. The objective of this study was to select a once daily regimen for further non-inferior study comparing the virological efficacy and safety of the first line once daily antiretroviral treatment regimens in the current HIV/AIDS guideline. The study design was a randomized, open label, multicenter, selection study. One arm was treated with efavirenz and the other with ritonavir-boosted atazanavir. A fixed-dose lamivudine plus abacavir were used in both arms. The primary endpoint was virologic success (viral load less than 50 copies/mL) rate at 48 weeks. Patients were followed-up to 96 weeks with safety as the secondary endpoint. Clinicaltrials.Gov (NCT00280969) and the University hospital Medical Information Network (UMIN000000243). A total of 71 participants were enrolled. Virologic success rates in both arms were similar at week 48 [efavirenz arm 28/36 (77.8%); atazanavir arm 27/35 (77.1%)], but were decreased at week 96 to 55.6% in the efavirenz arm and 68.8% in the atazanavir arm (p=0.33). At the 96-week follow-up, 52.8% of the EFV arm and 34.3% of the ATV/r arm reached total cholesterol more than 220 mg/dL and required treatment. None of the patients developed cardiovascular complications in this study by week 96. There was no significant difference in the efficacy of efavirenz and ritonavir-boosted atazanavir combined with lamivudine plus abacavir at 48 weeks. The evaluation of safety was extended to 96 weeks, which also showed no significant difference in both arms.
Bo, S; Ponzo, V; Evangelista, A; Ciccone, G; Goitre, I; Saba, F; Procopio, M; Cassader, M; Gambino, R
2017-05-01
The anti-inflammatory effects of the polyphenol resveratrol in patients with type 2 diabetes mellitus (T2DM) are controversial. Its role on pentraxin 3 (PTX3) concentrations, a human acute phase protein, has never been evaluated. Our aim was to determine whether a two-dosage resveratrol supplementation (500 and 40 mg/day) has an impact on PTX3 values in T2DM patients from a double-blind randomized placebo-controlled trial. Variations in total antioxidant status (TAS) were evaluated too. A total of 192 T2DM patients were randomized to receive resveratrol 500 mg/day (Resv 500 arm), resveratrol 40 mg/day (Resv 40 arm) or placebo for 6 months. At baseline and at the trial end, PTX3 and TAS values were determined. A dose-dependent increase in PTX3 concentrations of 4.7% (Resv 40 arm) and 26.3% (Resv 500 arm), and 8.0% reduction after placebo were found. Adjusted mean differences of change versus placebo were 0.16 (95% CI 0.01-0.32) and 0.25 (0.09-0.42) in the Resv 40 and Resv 500 arms, respectively. At subgroup analyses, lower diabetes duration, aspirin, alcohol use, younger age, female gender, smoking (Resv 500 arm) and female gender and aspirin use (Resv 40 arm) were associated with higher PTX3 increments. A dose-dependent increment in TAS values in the resveratrol arms (1.4 and 6.4% for Resv 40 and Resv 500, respectively), and a reduction in placebo arm (-8.9%) were observed. Adjusted mean differences of change were 28.5 (95% CI 10.1-46.8) and 44.8 (25.4-64.1) in the Resv 40 and Resv 500 arms, respectively. Resveratrol supplementation increased PTX3 and TAS levels in a dose-dependent manner in T2DM patients. At present, potential clinical implications of these results remain unclear. CLINICALTRIALS. NCT02244879.
Patterns of Growth after Kidney Transplantation among Children with ESRD
Franke, Doris; Thomas, Lena; Steffens, Rena; Pavičić, Leo; Gellermann, Jutta; Froede, Kerstin; Querfeld, Uwe; Haffner, Dieter
2015-01-01
Background and objectives Poor linear growth is a frequent complication of CKD. This study evaluated the effect of kidney transplantation on age-related growth of linear body segments in pediatric renal transplant recipients who were enrolled from May 1998 until August 2013 in the CKD Growth and Development observational cohort study. Design, setting, participants, & measurements Linear growth (height, sitting height, arm and leg lengths) was prospectively investigated during 1639 annual visits in a cohort of 389 pediatric renal transplant recipients ages 2–18 years with a median follow-up of 3.4 years (interquartile range, 1.9–5.9 years). Linear mixed-effects models were used to assess age-related changes and predictors of linear body segments. Results During early childhood, patients showed lower mean SD scores (SDS) for height (−1.7) and a markedly elevated sitting height index (ratio of sitting height to total body height) compared with healthy children (1.6 SDS), indicating disproportionate stunting (each P<0.001). After early childhood a sustained increase in standardized leg length and a constant decrease in standardized sitting height were noted (each P<0.001), resulting in significant catch-up growth and almost complete normalization of sitting height index by adult age (0.4 SDS; P<0.01 versus age 2–4 years). Time after transplantation, congenital renal disease, bone maturation, steroid exposure, degree of metabolic acidosis and anemia, intrauterine growth restriction, and parental height were significant predictors of linear body dimensions and body proportions (each P<0.05). Conclusions Children with ESRD present with disproportionate stunting. In pediatric renal transplant recipients, a sustained increase in standardized leg length and total body height is observed from preschool until adult age, resulting in restoration of body proportions in most patients. Reduction of steroid exposure and optimal metabolic control before and after transplantation are promising measures to further improve growth outcome. PMID:25352379
Patterns of growth after kidney transplantation among children with ESRD.
Franke, Doris; Thomas, Lena; Steffens, Rena; Pavičić, Leo; Gellermann, Jutta; Froede, Kerstin; Querfeld, Uwe; Haffner, Dieter; Živičnjak, Miroslav
2015-01-07
Poor linear growth is a frequent complication of CKD. This study evaluated the effect of kidney transplantation on age-related growth of linear body segments in pediatric renal transplant recipients who were enrolled from May 1998 until August 2013 in the CKD Growth and Development observational cohort study. Linear growth (height, sitting height, arm and leg lengths) was prospectively investigated during 1639 annual visits in a cohort of 389 pediatric renal transplant recipients ages 2-18 years with a median follow-up of 3.4 years (interquartile range, 1.9-5.9 years). Linear mixed-effects models were used to assess age-related changes and predictors of linear body segments. During early childhood, patients showed lower mean SD scores (SDS) for height (-1.7) and a markedly elevated sitting height index (ratio of sitting height to total body height) compared with healthy children (1.6 SDS), indicating disproportionate stunting (each P<0.001). After early childhood a sustained increase in standardized leg length and a constant decrease in standardized sitting height were noted (each P<0.001), resulting in significant catch-up growth and almost complete normalization of sitting height index by adult age (0.4 SDS; P<0.01 versus age 2-4 years). Time after transplantation, congenital renal disease, bone maturation, steroid exposure, degree of metabolic acidosis and anemia, intrauterine growth restriction, and parental height were significant predictors of linear body dimensions and body proportions (each P<0.05). Children with ESRD present with disproportionate stunting. In pediatric renal transplant recipients, a sustained increase in standardized leg length and total body height is observed from preschool until adult age, resulting in restoration of body proportions in most patients. Reduction of steroid exposure and optimal metabolic control before and after transplantation are promising measures to further improve growth outcome. Copyright © 2015 by the American Society of Nephrology.
Moderately hypofractionated conformal radiation treatment of thoracic esophageal carcinoma.
Ma, Jin-Bo; Wei, Lin; Chen, Er-Cheng; Qin, Guang; Song, Yi-Peng; Chen, Xiang-Ming; Hao, Chuan-Guo
2012-01-01
To prospectively assess the efficacy and safety of moderately hypofractionated conformal radiotherapy in patients with thoracic esophageal cancer. From Sept. 2002 to Oct. 2005, 150 eligible patients with T2-4N0-1M0 stage thoracic esophageal squamous cell cancers were enrolled to receive either conventional fractionated radiation (CFR) or moderately hypofractionated radiation (MHR) with a three- dimensional conformal radiation technique. Of the total, 74 received moderately hypofractionated radiation with total dose of 54-60 Gy/18-20 fractions for 3.5-4 weeks in the MHR arm, and 76 received conventional radiation with total dose of 60 Gy/30 fractions for 6 weeks in the CFR arm. Concurrent chemotherapy comprised of paclitaxel and cisplatin. Safety was evaluated, and local control and overall survival rates were calculated. Statistically significant differences between the CFR versus MHR arms were observed in local/regional failure rate (47.3% v 27.0%, P=0.034) and the percentage of patients with persistent local disease (26.3% v 10.8%, P=0.012). But 3 and 5-year overall survival rates (43.2%, 38.8% v 38.2%, 28.0%, respectively) were not different between the two arms (P=0.268). There were no significant differences in the incidences of grade 3 or higher acute toxicities (66.3% v 50.0%) and late complications rates (27.0% v 22.4%) between the MHR and CFR arms. Moderately hypofractionated, three-dimensional radiation treatment could improve the local control rate of esophageal cancer and potentially increase patient survival.
Raymond, Christiana J; Dengel, Donald R; Bosch, Tyler A
2018-03-01
Raymond, CJ, Dengel, DR, and Bosch, TA. Total and segmental body composition examination in collegiate football players using multifrequency bioelectrical impedance analysis and dual X-ray absorptiometry. J Strength Cond Res 32(3): 772-782, 2018-The current study examined the influence of player position on the agreement between multifrequency bioelectrical impedance analysis (MfBIA) and dual X-ray absorptiometry (DXA) when assessing total and segmental percent body fat (BF%), fat mass (FM), and fat-free mass (FFM) in National Collegiate Athletic Association Division I collegiate football athletes. Forty-four male collegiate athletes (age = 19 ± 1 year; height = 1.9 ± 1.0 m; and body mass = 106.4 ± 18.8 kg) participated. Player positions included: offensive linemen (OL; n = 7), tight ends (TE; n = 4), wide receivers (WR; n = 9), defensive linemen (DL; n = 6), defensive backs (DB; n = 8), linebackers (LB; n = 6), and running backs (RB; n = 4). Total and segmental body composition measured using MfBIA were compared with values obtained using DXA. Compared with DXA, MfBIA underestimated BF% (3.0 ± 3.8%), total FM (2.5 ± 4.3 kg), arm FM (0.4 ± 0.8 kg), arm FFM (1.4 ± 0.9 kg), leg FM (2.8 ± 2.0 kg), and leg FFM (5.4 ± 2.4 kg) (all p < 0.001; arm FM p = 0.002) and overestimated total FFM (-2.4 ± 4.5 kg) (p < 0.001). Limits of agreement (LOAs) were: ±7.39% (BF%), ±8.50 kg (total FM), ±1.50 kg (arm FM), ±1.83 kg (arm FFM), ±3.83 kg (leg FM), ±4.62 kg (leg FFM), and ±8.83 kg (total FFM). No significant differences were observed between devices for trunk FM (-0.3 ± 3.0 kg; p = 0.565) and trunk FFM (0.4 ± 2.4 kg; p = 0.278), with LOAs of ±5.92 and ±4.69 kg, respectively. Player position significantly affected all between-device mean body composition measurement differences (adjusted p ≤ 0.05), with OL demonstrating the greatest effect on each variable. Therefore, MfBIA does not seem accurate in examining between-player body composition in college football players.
SpArcFiRe: Scalable automated detection of spiral galaxy arm segments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, Darren R.; Hayes, Wayne B., E-mail: drdavis@uci.edu, E-mail: whayes@uci.edu
Given an approximately centered image of a spiral galaxy, we describe an entirely automated method that finds, centers, and sizes the galaxy (possibly masking nearby stars and other objects if necessary in order to isolate the galaxy itself) and then automatically extracts structural information about the spiral arms. For each arm segment found, we list the pixels in that segment, allowing image analysis on a per-arm-segment basis. We also perform a least-squares fit of a logarithmic spiral arc to the pixels in that segment, giving per-arc parameters, such as the pitch angle, arm segment length, location, etc. The algorithm takesmore » about one minute per galaxies, and can easily be scaled using parallelism. We have run it on all ∼644,000 Sloan objects that are larger than 40 pixels across and classified as 'galaxies'. We find a very good correlation between our quantitative description of a spiral structure and the qualitative description provided by Galaxy Zoo humans. Our objective, quantitative measures of structure demonstrate the difficulty in defining exactly what constitutes a spiral 'arm', leading us to prefer the term 'arm segment'. We find that pitch angle often varies significantly segment-to-segment in a single spiral galaxy, making it difficult to define the pitch angle for a single galaxy. We demonstrate how our new database of arm segments can be queried to find galaxies satisfying specific quantitative visual criteria. For example, even though our code does not explicitly find rings, a good surrogate is to look for galaxies having one long, low-pitch-angle arm—which is how our code views ring galaxies. SpArcFiRe is available at http://sparcfire.ics.uci.edu.« less
Force-induced desorption of 3-star polymers: a self-avoiding walk model
NASA Astrophysics Data System (ADS)
Janse van Rensburg, E. J.; Whittington, S. G.
2018-05-01
We consider a simple cubic lattice self-avoiding walk model of 3-star polymers adsorbed at a surface and then desorbed by pulling with an externally applied force. We determine rigorously the free energy of the model in terms of properties of a self-avoiding walk, and show that the phase diagram includes four phases, namely a ballistic phase where the extension normal to the surface is linear in the length, an adsorbed phase and a mixed phase, in addition to the free phase where the model is neither adsorbed nor ballistic. In the adsorbed phase all three branches or arms of the star are adsorbed at the surface. In the ballistic phase two arms of the star are pulled into a ballistic phase, while the remaining arm is in a free phase. In the mixed phase two arms in the star are adsorbed while the third arm is ballistic. The phase boundaries separating the ballistic and mixed phases, and the adsorbed and mixed phases, are both first order phase transitions. The presence of the mixed phase is interesting because it does not occur for pulled, adsorbed self-avoiding walks. In an atomic force microscopy experiment it would appear as an additional phase transition as a function of force.
Changes in kinematics and arm-leg coordination during a 100-m breaststroke swim.
Oxford, Samuel W; James, Rob S; Price, Michael J; Payton, Carl J; Duncan, Michael J
2017-08-01
The purpose of this study was to compare arm-leg coordination and kinematics during 100 m breaststroke in 26 (8 female; 18 male) specialist breaststroke swimmers. Laps were recorded using three 50-Hz underwater cameras. Heart rate and blood lactate were measured pre- and post-swim. Arm-leg coordination was defined using coordination phases describing continuity between recovery and propulsive phases of upper and lower limbs: coordination phase 1 (time between end of leg kick and start of the arm pull phases); and coordination phase 2 (time between end of arm pull and start of leg kick phases). Duration of stroke phases, coordination phases, swim velocity, stroke length (SL), stroke rate (SR) and stroke index (SI) were analysed during the last three strokes of each lap that were unaffected by turning or finishing. Significant changes in velocity, SI and SL (P < 0.05) were found between laps. Both sexes showed significant increase (P < 0.05) in heart rate and blood lactate pre- to post-swim. Males had significantly (P < 0.01) faster swim velocities resulting from longer SLs (P = 0.016) with no difference in SR (P = 0.064). Sex differences in kinematic parameters can be explained by anthropometric differences providing males with increased propelling efficiency.
Octopuses use a human-like strategy to control precise point-to-point arm movements.
Sumbre, Germán; Fiorito, Graziano; Flash, Tamar; Hochner, Binyamin
2006-04-18
One of the key problems in motor control is mastering or reducing the number of degrees of freedom (DOFs) through coordination. This problem is especially prominent with hyper-redundant limbs such as the extremely flexible arm of the octopus. Several strategies for simplifying these control problems have been suggested for human point-to-point arm movements. Despite the evolutionary gap and morphological differences, humans and octopuses evolved similar strategies when fetching food to the mouth. To achieve this precise point-to-point-task, octopus arms generate a quasi-articulated structure based on three dynamic joints. A rotational movement around these joints brings the object to the mouth . Here, we describe a peripheral neural mechanism-two waves of muscle activation propagate toward each other, and their collision point sets the medial-joint location. This is a remarkably simple mechanism for adjusting the length of the segments according to where the object is grasped. Furthermore, similar to certain human arm movements, kinematic invariants were observed at the joint level rather than at the end-effector level, suggesting intrinsic control coordination. The evolutionary convergence to similar geometrical and kinematic features suggests that a kinematically constrained articulated limb controlled at the level of joint space is the optimal solution for precise point-to-point movements.
Feedback control of vibrations in a moving flexible robot arm with rotary and prismatic joints
NASA Technical Reports Server (NTRS)
Wang, P. K. C.; Wei, Jin-Duo
1987-01-01
A robot with a long extendible flexible arm which can also undergo both vertical translation and rotary motion is considered. First, A distributed-parameter model for the robot arm dynamics is developed. It is found that the extending motion could enhance the arm vibrations. Then, a Galerkin-type approximation based on an appropriate time-dependent basis for the solution space is used to obtain an approximate finite-dimensional model for simulation studies. A feedback control for damping the motion-induced vibrations is derived by considering the time rate-of-change of the total vibrational energy of the flexible arm. The authors conclude with some simulation results for a special case with the proposed control law.
Malmström, Eva-Maj; Olsson, Joakim; Baldetorp, Johan; Fransson, Per-Anders
2015-12-01
Long-term use of unfavorable postures, congenital deformations and degenerative processes associated with aging or disease may generate an increased thoracic curvature resulting in pain and disability. We wanted to examine whether a slouched postural alignment with increased thoracic kyphosis changes the shoulder kinematics and muscle activity in upper trapezius (UT), lower trapezius (LT) and serratus anterior (SA) during arm elevation. The aim was to determine if a slouched posture influences range of motion, muscle activation patterns, maximal muscle activity and the total muscle work required when performing arm elevations. Twelve male subjects (23.3 ± 1.5 years) performed maximum arm elevations in upright and slouched postures. A combined 3D movement and EMG system recorded arm movements and spine curvature simultaneously with EMG activity in the UT, LT and SA. Slouched posture affected the biomechanical conditions by significantly decreasing maximum arm elevation by ~15° (p < 0.001) and decreasing arm movement velocity by ~8 % during movements upwards (p < 0.001) and downwards (p = 0.034). The peak muscle activity increased in all muscles: UT (p = 0.034, +32.3 %), LT (p = 0.001, +48.6 %) and SA (p = 0.007, +20.9 %). The total muscle work increased significantly in the slouched posture during movements upwards: UT (p = 0.003, +36.6 %), LT (p < 0.001, +89.0 %), SA (p = 0.002, +19.4 %) and downwards: UT (p = 0.012, +29.8 %) and LT (p < 0.001, +122.5 %). An increased thoracic kyphosis was found associated with marked increased physical costs when performing arm movements. Hence, patients suffering from neck-shoulder pain and disability should be investigated and treated for defective thoracic curvature issues.
Navy DDG-1000 and DDG-51 Destroyer Programs: Background, Oversight Issues, and Options for Congress
2009-06-04
Aegis combat system and the arming of the ship with the SM-3, a version of the Navy’s Standard Missile that is designed for BMD operations.6 Total...and assigning the construction of those ships to GD/BIW and/or NGSB; • procuring AGS- armed versions of the basic LPD-17 class hull—another option...subcommittee of the House Armed Services Committee.24 22 Christopher P. Cavas, “All
Mérol, Jean-Claude; Charpiot, Anne; Langagne, Thibault; Hémar, Patrick; Ackerstaff, Annemieke H; Hilgers, Frans J M
2012-02-01
Assessment of immediate postoperative airway humidification after total laryngectomy (TLE), comparing the use of an external humidifier (EH) with humidification through a heat and moisture exchanger (HME). Randomized controlled trial (RCT). Fifty-three patients were randomized into the standard (control) EH (N = 26) or the experimental HME arm (N = 27). Compliance, pulmonary and sleeping problems, patients' and nursing staff satisfaction, nursing time, and cost-effectiveness were assessed with trial-specific structured questionnaires and tally sheets. In the EH arm data were available for all patients, whereas in the HME arm data were incomplete for four patients. The 24/7 compliance rate in the EH arm was 12% and in the HME arm 87% (77% if the four nonevaluable patients are considered noncompliant). Compliance and patients' satisfaction were significantly better, and the number of coughing episodes, mucus expectoration for clearing the trachea, and sleeping disturbances were significantly less in the HME arm (P < .001). This was also the case for nursing time and nursing staff satisfaction and preference. This RCT clearly shows the benefits of immediate postoperative airway humidification by means of an HME over the use of an EH after TLE. This study therefore underlines that HMEs presently can be considered the better option for early postoperative airway humidification after TLE. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.
Bilimoria, Karl Y; Quinn, Christopher M; Dahlke, Allison R; Kelz, Rachel R; Shea, Judy A; Rajaram, Ravi; Love, Remi; Kreutzer, Lindsey; Biester, Thomas; Yang, Anthony D; Hoyt, David B; Lewis, Frank R
2017-02-01
The Flexibility in Duty Hour Requirements for Surgical Trainees (FIRST) Trial randomly assigned surgical residency programs to either standard duty hour policies or flexible policies that eliminated caps on shift lengths and time off between shifts. Our objectives were to assess adherence to duty hour requirements in the Standard Policy arm and examine how often and why duty hour flexibility was used in the Flexible Policy arm. A total of 3,795 residents in the FIRST trial completed a survey in January 2016 (response rate >95%) that asked how often and why they exceeded current standard duty hour limits in both study arms. Flexible Policy interns worked more than 16 hours continuously at least once in a month more frequently than Standard Policy residents (86% vs 37.8%). Flexible Policy residents worked more than 28 hours once in a month more frequently than Standard Policy residents (PGY1: 64% vs 2.9%; PGY2 to 3: 62.4% vs 41.9%; PGY4 to 5: 52.2% vs 36.6%), but this occurred most frequently only 1 to 2 times per month. Although residents reported working more than 80 hours in a week 3 or more times in the most recent month more frequently under Flexible Policy vs Standard Policy (19.9% vs 16.2%), the difference was driven by interns (30.9% vs 19.6%), and there were no significant differences in exceeding 80 hours among PGY2 to 5 residents. The most common reasons reported for extending duty hours were facilitating care transitions (76.6%), stabilizing critically ill patients (70.7%), performing routine responsibilities (67.9%), and operating on patients known to the trainee (62.0%). There were differences in duty hours worked by residents in the Flexible vs Standard Policy arms of the FIRST trial, but it appeared that residents generally used the flexibility for patient care and educational opportunities selectively. Copyright © 2016 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Mäusezahl, Daniel; Christen, Andri; Pacheco, Gonzalo Duran; Tellez, Fidel Alvarez; Iriarte, Mercedes; Zapata, Maria E.; Cevallos, Myriam; Hattendorf, Jan; Cattaneo, Monica Daigl; Arnold, Benjamin; Smith, Thomas A.; Colford, John M.
2009-01-01
Background Solar drinking water disinfection (SODIS) is a low-cost, point-of-use water purification method that has been disseminated globally. Laboratory studies suggest that SODIS is highly efficacious in inactivating waterborne pathogens. Previous field studies provided limited evidence for its effectiveness in reducing diarrhoea. Methods and Findings We conducted a cluster-randomized controlled trial in 22 rural communities in Bolivia to evaluate the effect of SODIS in reducing diarrhoea among children under the age of 5 y. A local nongovernmental organisation conducted a standardised interactive SODIS-promotion campaign in 11 communities targeting households, communities, and primary schools. Mothers completed a daily child health diary for 1 y. Within the intervention arm 225 households (376 children) were trained to expose water-filled polyethyleneteraphtalate bottles to sunlight. Eleven communities (200 households, 349 children) served as a control. We recorded 166,971 person-days of observation during the trial representing 79.9% and 78.9% of the total possible person-days of child observation in intervention and control arms, respectively. Mean compliance with SODIS was 32.1%. The reported incidence rate of gastrointestinal illness in children in the intervention arm was 3.6 compared to 4.3 episodes/year at risk in the control arm. The relative rate of diarrhoea adjusted for intracluster correlation was 0.81 (95% confidence interval 0.59–1.12). The median length of diarrhoea was 3 d in both groups. Conclusions Despite an extensive SODIS promotion campaign we found only moderate compliance with the intervention and no strong evidence for a substantive reduction in diarrhoea among children. These results suggest that there is a need for better evidence of how the well-established laboratory efficacy of this home-based water treatment method translates into field effectiveness under various cultural settings and intervention intensities. Further global promotion of SODIS for general use should be undertaken with care until such evidence is available. Trial Registration www.ClinicalTrials.gov NCT00731497 Please see later in the article for Editors' Summary PMID:19688036
Woodside, Michael D.
1994-01-01
The City of Virginia Beach currently (1994) supplies water to about 400,000 people in southeastern Virginia. The city plans to withdraw water from the Pea Hill Arm of Lake Gaston to meet projected water needs of the population to the year 2030. The purpose of this report is to (1) describe the temporal and spatial distribution of selected water-quality constituents, (2) document current (1989) land use and land cover in the Pea Hill Arm drainage basin, and (3) discuss relations, if any, between the quality of water in the inlets within the Pea Hill Arm and land uses. The report focuses on water-quality problems in the basin, including changes in concentrations of major ions, nutrients, and algae associated with urban development adjacent to water bodies.The Pea Hill Arm was classified as mesotrophic on the basis of the range of concentrations of total phosphorus (0.001 to 0.61 milligrams per liter); the range of concentrations of total organic-plus-ammonia nitrogen (0.2 to 1.4 milligrams per liter); and the range of concentrations of chlorophyll a (1.4 to 56 micrograms per liter). These water-quality data were collected at 3 feet below the water surface during water years 1989-90.Thermal stratification in Pea Hill Arm generally began in April and ended in September. Water below a depth of about 25 feet generally became anoxic by June. Destratification generally began in late September and was completed by November. Lake Gaston followed the same general stratification and destratification pattern as Pea Hill Arm, except Lake Gaston was partially destratified during the summer when large amounts of water were released from John H. Kerr Reservoir and Lake Gaston Dams. During water year 1988, streamflows were 33 percent below the long-term mean-annual streamflows at one of the major streams to Lake Gaston. Low streamflows contributed to elevated specific conductances and concentrations of sodium, calcium, magnesium, and alkalinity from October 1988 to February 1989 at sampling stations in the Pea Hill Arm and Lake Gaston.About 75 percent of the land use in the Pea Hill Arm is forest land. The remaining 25 percent of the Pea Hill Arm drainage basin is 8 percent pasture/open land, 8 percent open water, 6 percent residential land, and 3 percent cropland. No statistical relations are present between water-quality constituents measured and developed land uses within 11 basins in the Pea Hill Arm Basin, except during periods of stormwater runoff. During a stormwater-runoff event, there was a relation between total nitrite plus nitrate and land use (Kendall's tau correlation coefficient of 0.69). The relation between the developed land use and total nitrite plus nitrate can also be related to the increased ground-water inputs during high base-flow periods.Spatial differences in water-quality constituents as determined by Wilcoxon (matched-pairs) signed-rank tests and cluster analyses were longitudinal and primarily grouped into riverine, transition, and lacustrine zones. These zones were grouped on the basis of flow characteristics and nutrient concentrations.
Galaxy Zoo: star formation versus spiral arm number
NASA Astrophysics Data System (ADS)
Hart, Ross E.; Bamford, Steven P.; Casteels, Kevin R. V.; Kruk, Sandor J.; Lintott, Chris J.; Masters, Karen L.
2017-06-01
Spiral arms are common features in low-redshift disc galaxies, and are prominent sites of star formation and dust obscuration. However, spiral structure can take many forms: from galaxies displaying two strong 'grand design' arms to those with many 'flocculent' arms. We investigate how these different arm types are related to a galaxy's star formation and gas properties by making use of visual spiral arm number measurements from Galaxy Zoo 2. We combine ultraviolet and mid-infrared (MIR) photometry from GALEX and WISE to measure the rates and relative fractions of obscured and unobscured star formation in a sample of low-redshift SDSS spirals. Total star formation rate has little dependence on spiral arm multiplicity, but two-armed spirals convert their gas to stars more efficiently. We find significant differences in the fraction of obscured star formation: an additional ˜10 per cent of star formation in two-armed galaxies is identified via MIR dust emission, compared to that in many-armed galaxies. The latter are also significantly offset below the IRX-β relation for low-redshift star-forming galaxies. We present several explanations for these differences versus arm number: variations in the spatial distribution, sizes or clearing time-scales of star-forming regions (I.e. molecular clouds), or contrasting recent star formation histories.
Jiang, Wei; Mahnken, Jonathan D; He, Jianghua; Mayo, Matthew S
2016-11-01
For two-arm randomized phase II clinical trials, previous literature proposed an optimal design that minimizes the total sample sizes subject to multiple constraints on the standard errors of the estimated event rates and their difference. The original design is limited to trials with dichotomous endpoints. This paper extends the original approach to be applicable to phase II clinical trials with endpoints from the exponential dispersion family distributions. The proposed optimal design minimizes the total sample sizes needed to provide estimates of population means of both arms and their difference with pre-specified precision. Its applications on data from specific distribution families are discussed under multiple design considerations. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Distance Education at Arm's Length: Outsourcing of Distance Education Marking.
ERIC Educational Resources Information Center
Smith, Erica; Coombe, Kennece
Two research projects focused on use of casual markers (graders) for correcting and grading distance education (DE) students' work. A Charles Sturt University project convened focus groups of DE students, casual DE markers, and lecturers who "managed" markers to uncover concerns. University of South Australia research focused on pedagogical issues…
30 CFR 1206.458 - Determination of washing allowances.
Code of Federal Regulations, 2011 CFR
2011-07-01
... contract. However, before any deduction may be taken, the lessee must submit a completed page one of Form...-arm's-length or no contract situations. However, before any estimated or actual deduction may be taken... allowances specified in paragraphs (c)(1)(v) and (c)(1)(vi) of this section, the lessee shall submit page one...
Stevens, Simon
2005-02-17
Control of the tariff system should be handed over to an arms-length technical agency similar to the U.S's Medicare Payments Advisory Commission, according to HSJ columnist and former prime ministerial adviser Simon Stevens. He also warns that the 'understandable decision' to slow implementation of the new system means that the elective tariff 'will be easily gamed'.
29 CFR 4.11 - Arm's length proceedings.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Act. See Trinity Services, Inc. v. Marshall, 593 F.2d 1250 (D.C. Cir. 1978). A finding as to whether a...)(3)(ii) of this section where the Administrator determines that material facts are in dispute, shall... that no material facts are in dispute, the Administrator shall refer the issue and the record compiled...
29 CFR 4.11 - Arm's length proceedings.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Act. See Trinity Services, Inc. v. Marshall, 593 F.2d 1250 (D.C. Cir. 1978). A finding as to whether a...)(3)(ii) of this section where the Administrator determines that material facts are in dispute, shall... that no material facts are in dispute, the Administrator shall refer the issue and the record compiled...
29 CFR 4.11 - Arm's length proceedings.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Act. See Trinity Services, Inc. v. Marshall, 593 F.2d 1250 (D.C. Cir. 1978). A finding as to whether a...)(3)(ii) of this section where the Administrator determines that material facts are in dispute, shall... that no material facts are in dispute, the Administrator shall refer the issue and the record compiled...
29 CFR 4.11 - Arm's length proceedings.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Act. See Trinity Services, Inc. v. Marshall, 593 F.2d 1250 (D.C. Cir. 1978). A finding as to whether a...)(3)(ii) of this section where the Administrator determines that material facts are in dispute, shall... that no material facts are in dispute, the Administrator shall refer the issue and the record compiled...
29 CFR 4.11 - Arm's length proceedings.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Act. See Trinity Services, Inc. v. Marshall, 593 F.2d 1250 (D.C. Cir. 1978). A finding as to whether a...)(3)(ii) of this section where the Administrator determines that material facts are in dispute, shall... that no material facts are in dispute, the Administrator shall refer the issue and the record compiled...
ERIC Educational Resources Information Center
Hackett, Julie L.
2015-01-01
In "Building Relationships, Yielding Results," the seasoned superintendent of an urban school district provides a clear road map for effective collaboration with school boards and the type of relationship-building required to achieve long-term, sustainable reforms. Instead of keeping school board members at arm's length or inundating…
26 CFR 25.2512-8 - Transfers for insufficient consideration.
Code of Federal Regulations, 2011 CFR
2011-04-01
... the value of the property transferred by the donor exceeds the value in money or money's worth of the... course of business (a transaction which is bona fide, at arm's length, and free from any donative intent), will be considered as made for an adequate and full consideration in money or money's worth. A...
26 CFR 25.2512-8 - Transfers for insufficient consideration.
Code of Federal Regulations, 2010 CFR
2010-04-01
... the value of the property transferred by the donor exceeds the value in money or money's worth of the... course of business (a transaction which is bona fide, at arm's length, and free from any donative intent), will be considered as made for an adequate and full consideration in money or money's worth. A...
26 CFR 25.2512-8 - Transfers for insufficient consideration.
Code of Federal Regulations, 2013 CFR
2013-04-01
... the value of the property transferred by the donor exceeds the value in money or money's worth of the... course of business (a transaction which is bona fide, at arm's length, and free from any donative intent), will be considered as made for an adequate and full consideration in money or money's worth. A...
26 CFR 25.2512-8 - Transfers for insufficient consideration.
Code of Federal Regulations, 2012 CFR
2012-04-01
... the value of the property transferred by the donor exceeds the value in money or money's worth of the... course of business (a transaction which is bona fide, at arm's length, and free from any donative intent), will be considered as made for an adequate and full consideration in money or money's worth. A...
26 CFR 25.2512-8 - Transfers for insufficient consideration.
Code of Federal Regulations, 2014 CFR
2014-04-01
... the value of the property transferred by the donor exceeds the value in money or money's worth of the... course of business (a transaction which is bona fide, at arm's length, and free from any donative intent), will be considered as made for an adequate and full consideration in money or money's worth. A...
75 FR 18536 - Agency Information Collection Activities: Proposed Collection, Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-12
...)......... Submit all arm's-length AUDIT PROCESS. See Note. transportation contracts, production agreements... based on the life of equipment or reserves, or a unit of production method. 206.458(c)(1)(iv), (c)(2)(vi... required by various laws to manage mineral resources production on Federal and Indian lands, collect the...
"Critical Friends": Exploring Arm's Length Actor Relationships to Local Government in Education
ERIC Educational Resources Information Center
Exley, Sonia
2016-01-01
Discussions charting the changing role of local government in education have often focused extensively on "concrete" policy changes over time, but have provided less detail on the contribution to changing power relations of less tangible shifts. Drawing on Foucauldian notions of discourse and governmentality, in this paper, detailed…
Karyotype variation is indicative of subgenomic and ecotypic differentiation in switchgrass
USDA-ARS?s Scientific Manuscript database
A cytogenetic study was conducted on a dihaploid individual (2n'='2X'='18) of switchgrass to establish a chromosome karyotype. Size differences, condensation patterns, and arm-length ratios were used as identifying features and fluorescence in-situ hybridization (FISH) assigned 5S and 45S rDNA loci...
Ballistic Missile Propellant Evaluation Test Motor System (Super BATES)
1974-11-25
and laminated parts are debulked and 75 cured in a hydroclave at 950 psi (minimum) and 3000 F, and machined to final dimensions. All molded parts are...to pick dlf- ferent lengths of motors simply hy relocating and pinning the cross arms. flatbed truck with forklift will be i adequate for moving
29 CFR 4204.1 - Purpose and scope.
Code of Federal Regulations, 2010 CFR
2010-07-01
... PLANS VARIANCES FOR SALE OF ASSETS General § 4204.1 Purpose and scope. (a) Purpose. Under section 4204 of ERISA, an employer that ceases covered operations under a multiemployer plan, or ceases to have an obligation to contribute for such operations, because of a bona fide, arm's-length sale of assets to an...
Burau, Viola
2009-07-01
Studies of German health policy often highlight institutional constraints to reform. However, based on a case study of the introduction of clinical standards as part of the Disease Management Programmes for chronic illnesses, this article suggests that negotiating reform at an arm's length from the state can also lead to governance change, although the strengthening of hierarchy is not as prominent as that in some of the countries studied in this special issue. As such, the case of Germany offers interesting insights into the politics of governance change that occur in the shadow, but largely without the direct involvement of the state, which is typical of a corporatist health-care state. In this respect, the analysis identifies three leverages for change. First, the change in medical governance explicitly builds on earlier reforms and gives the reform alliance a competitive edge. Second, the organisations of the joint self-administration, as a more or less open ally of the state, play an influential role throughout the reform process. Importantly and third, this is complemented by the state steering at a distance.
Electronically controlled cable wrapper
Young, Thomas M.
1984-01-01
A spindle assembly engages and moves along a length of cable to be wrapped with insulating tape. Reels of insulating tape are mounted on a outer rotatable spindle which revolves around the cable to dispense insulating tape. The rate of movement of the spindle assembly along the length of the cable is controlled by a stepper motor which is programmably synchronized to the rate at which rotatable spindle wraps the cable. The stepper motor drives a roller which engages the cable and moves the spindle assembly along the length of the cable as it is being wrapped. The spindle assembly is mounted at the end of an articulated arm which allows free movement of the spindle assembly and allows the spindle assembly to follow lateral movement of the cable.
Electronically controlled cable wrapper
Young, T.M.
1982-08-17
A spindle assembly engages and moves along a length of cable to be wrapped with insulating tape. Reels of insulating tape are mounted on a outer rotatable spindle which revolves around the cable to dispense insulating tape. The rate of movement of the spindle assembly along the length of the cable is controlled by a stepper motor which is programmably synchronized to the rate at which rotatable spindle wraps the cable. The stepper motor drives a roller which engages the cable and moves the spindle assembly along the length of the cable as it is being wrapped. The spindle assembly is mounted at the end of an articulated arm which allows free movement of the spindle assembly and allows the spindle assembly to follow lateral movement of the cable.
Han, Chao; Yang, Ben; Zuo, Wen-Shu; Zheng, Gang; Yang, Li; Zheng, Mei-Zhu
2016-01-01
Objective The axillary reverse mapping (ARM) technique has recently been developed to prevent lymphedema by preserving the arm lymphatic drainage during sentinel lymph node biopsy (SLNB) or axillary lymph node dissection (ALND) procedures. The objective of this systematic review and meta-analysis was to evaluate the feasibility and oncological safety of ARM. Methods We searched Medline, Embase, Web of science, Scopus, and the Cochrane Library for relevant prospective studies. The identification rate of ARM nodes, the crossover rate of SLN-ARM nodes, the proportion of metastatic ARM nodes, and the incidence of complications were pooled into meta-analyses by the random-effects model. Results A total of 24 prospective studies were included into meta-analyses, of which 11 studies reported ARM during SLNB, and 18 studies reported ARM during SLNB. The overall identification rate of ARM nodes was 38.2% (95% CI 32.9%-43.8%) during SLNB and 82.8% (78.0%-86.6%) during ALND, respectively. The crossover rate of SLN-ARM nodes was 19.6% (95% CI 14.4%-26.1%). The metastatic rate of ARM nodes was 16.9% (95% CI 14.2%-20.1%). The pooled incidence of lymphedema was 4.1% (95% CI 2.9–5.9%) for patients undergoing ARM procedure. Conclusions The ARM procedure was feasible during ALND. Nevertheless, it was restricted by low identification rate of ARM nodes during SLNB. ARM was beneficial for preventing lymphedema. However, this technique should be performed with caution given the possibility of crossover SLN-ARM nodes and metastatic ARM nodes. ARM appeared to be unsuitable for patients with clinically positive breast cancer due to oncological safety concern. PMID:26919589
Arm Activity During Daily Life in Individuals With Chronic Obstructive Pulmonary Disease.
Janaudis-Ferreira, Tania; Mathur, Sunita; Romano, Julia Marie; Goldstein, Roger Samuel; Brooks, Dina
2016-01-01
To determine whether individuals with chronic obstructive pulmonary disease (COPD) have decreased arm activity during daily life compared with healthy controls and explore the relationships between arm activity during daily life and arm functional measures in individuals with COPD. This was a prospective cross-sectional study that included 30 people with COPD and 14 healthy controls. Subjects attended a single assessment session in which measurements of arm exercise capacity, arm functional performance, self-perception of performance during activities of daily living (ADL), shoulder and elbow flexion force and biceps and triceps thickness were performed. On completion of this session, participants were issued a wrist actigraph and asked to wear the device on the dominant arm for 24 hours for 7 consecutive days. Compared with healthy controls, patients with COPD presented decreased total activity level in daily life (P = .001). When corrected for walking, the level of arm activity did not differ between individuals with COPD and healthy controls (P = .62). No correlations were found between arm activity and arm exercise capacity, arm functional performance, upper limb muscle strength, and self-perception of performance during ADL (r =-0.20 to 0.14; all P ≥ .10). Arm activity intensity in individuals with COPD did not differ from that of healthy controls when measured by a wrist actigraph. Moreover, arm activity was not associated with other clinical outcomes of arm function. Disability during ADL is multifactorial, and only limited inferences of function can be made from accelerometer data.
Lee, Kwang Won; Kim, Yong In; Kim, Ha Yong; Yang, Dae Suk; Lee, Gyu Sang; Choy, Won Sik
2016-09-01
There have been few reports on altered kinematics of the shoulder after reverse total shoulder arthroplasty (RTSA). We investigated differences in 3-dimensional (3D) scapular motions assessed using an optical tracking system between RTSA treated shoulders and asymptomatic contralateral shoulders during arm motion. Thirteen patients who underwent RTSA were assessed for active arm elevation in 2 distinct elevation planes (sagittal plane flexion and scapular plane abduction). Their mean age was 72 years (range, 69 to 79 years) and the mean follow-up was 24.4 months (range, 13 to 48 months). The dominant side was the right side in all the 13 patients, and it was also the side treated with RTSA. Scapular kinematics was recorded with an optical tracking system. The scapular kinematics and the scapulohumeral rhythm (SHR) of the RTSA shoulders and asymptomatic contralateral shoulders were recorded and analyzed during arm elevation. There were no significant differences in internal/external rotation and anterior/posterior tilting of the scapula between shoulders during arm motion (p > 0.05). However, upward rotation of the scapula differed significantly during arm motion (p = 0.035 for sagittal plane flexion; p = 0.046 for scapular plane abduction). There were significant differences in the SHR between the two shoulders (p = 0.016 for sagittal plane flexion; p = 0.021 for scapular plane abduction). The shoulder kinematics after RTSA showed significant differences from the contralateral asymptomatic shoulders. Increased upward rotation and decreased SHR after RTSA indicate that RTSA shoulders use more scapulothoracic motion and less glenohumeral motion to elevate the arm.
Lee, Kwang Won; Kim, Ha Yong; Yang, Dae Suk; Lee, Gyu Sang; Choy, Won Sik
2016-01-01
Background There have been few reports on altered kinematics of the shoulder after reverse total shoulder arthroplasty (RTSA). We investigated differences in 3-dimensional (3D) scapular motions assessed using an optical tracking system between RTSA treated shoulders and asymptomatic contralateral shoulders during arm motion. Methods Thirteen patients who underwent RTSA were assessed for active arm elevation in 2 distinct elevation planes (sagittal plane flexion and scapular plane abduction). Their mean age was 72 years (range, 69 to 79 years) and the mean follow-up was 24.4 months (range, 13 to 48 months). The dominant side was the right side in all the 13 patients, and it was also the side treated with RTSA. Scapular kinematics was recorded with an optical tracking system. The scapular kinematics and the scapulohumeral rhythm (SHR) of the RTSA shoulders and asymptomatic contralateral shoulders were recorded and analyzed during arm elevation. Results There were no significant differences in internal/external rotation and anterior/posterior tilting of the scapula between shoulders during arm motion (p > 0.05). However, upward rotation of the scapula differed significantly during arm motion (p = 0.035 for sagittal plane flexion; p = 0.046 for scapular plane abduction). There were significant differences in the SHR between the two shoulders (p = 0.016 for sagittal plane flexion; p = 0.021 for scapular plane abduction). Conclusions The shoulder kinematics after RTSA showed significant differences from the contralateral asymptomatic shoulders. Increased upward rotation and decreased SHR after RTSA indicate that RTSA shoulders use more scapulothoracic motion and less glenohumeral motion to elevate the arm. PMID:27583116
Stereotypical reaching movements of the octopus involve both bend propagation and arm elongation.
Hanassy, S; Botvinnik, A; Flash, T; Hochner, B
2015-05-13
The bend propagation involved in the stereotypical reaching movement of the octopus arm has been extensively studied. While these studies have analyzed the kinematics of bend propagation along the arm during its extension, possible length changes have been ignored. Here, the elongation profiles of the reaching movements of Octopus vulgaris were assessed using three-dimensional reconstructions. The analysis revealed that, in addition to bend propagation, arm extension movements involve elongation of the proximal part of the arm, i.e., the section from the base of the arm to the propagating bend. The elongations are quite substantial and highly variable, ranging from an average strain along the arm of -0.12 (i.e. shortening) up to 1.8 at the end of the movement (0.57 ± 0.41, n = 64 movements, four animals). Less variability was discovered in an additional set of experiments on reaching movements (0.64 ± 0.28, n = 30 movements, two animals), where target and octopus positions were kept more stationary. Visual observation and subsequent kinematic analysis suggest that the reaching movements can be broadly segregated into two groups. The first group involves bend propagation beginning at the base of the arm and propagating towards the arm tip. In the second, the bend is formed or present more distally and reaching is achieved mainly by elongation and straightening of the segment proximal to the bend. Only in the second type of movements is elongation significantly positively correlated with the distance of the bend from the target. We suggest that reaching towards a target is generated by a combination of both propagation of a bend along the arm and arm elongation. These two motor primitives may be combined to create a broad spectrum of reaching movements. The dynamical model, which recapitulates the biomechanics of the octopus muscular hydrostatic arm, suggests that achieving the observed elongation requires an extremely low ratio of longitudinal to transverse muscle force (<0.0016 for an average strain along the arm of around 0.5). This was not observed and moreover such extremely low value does not seem to be physiologically possible. Hence the assumptions made in applying the dynamic model to behaviors such as static arm stiffening that leads to arm extension through bend propagation and the patterns of activation used to simulate such behaviors should be modified to account for movements combining bend propagation and arm elongation.
Truong, Minh Tam; Zhang, Qiang; Rosenthal, David I; List, Marcie; Axelrod, Rita; Sherman, Eric; Weber, Randal; Nguyen-Tân, Phuc Felix; El-Naggar, Adel; Konski, André; Galvin, James; Schwartz, David; Trotti, Andy; Silverman, Craig; Singh, Anurag; Godette, Karen; Bonner, James A; Jones, Christopher U; Garden, Adam S; Shenouda, George; Matthiesen, Chance; Le, Quynh-Thu; Bruner, Deborah
2017-03-15
To analyze the quality of life (QOL) and performance status (PS) (secondary outcome) in patients with stage III to IV head and neck cancer (HNC) enrolled on a prospective randomized phase 3 trial comparing radiation-cisplatin without cetuximab (CIS) or with cetuximab (CET/CIS). The QOL hypothesis proposed a between-arm difference in Functional Assessment of Cancer Therapy-Head and Neck (FACT-HN) total score of ≥10% of the instrument range from baseline to 1 year. Patients who gave consent to the QOL/PS study completed the FACT-HN, Performance Status Scale for HNC (PSS-HN), and EuroQol (EQ-5D) at baseline through to 5 years. The pretreatment QOL/PS scores were correlated with outcome and p16 status in patients with oropharyngeal cancer (OPC). Of 818 analyzable patients, the 1-year change from baseline score for FACT-HN total was -0.41 (CIS arm) and -5.11 (CET/CIS arm) (P=.016), representing a 3.2% between-arm change of the FACT-HN total score. The mean EQ-5D index and PSS-HN scores were not significantly different between arms. The p16-positive OPC patients had significantly higher baseline and 1-year scores for PSS-HN, FACT-HN total, physical and functional subscales, and 2-years for the EQ-5D index compared with p16-negative OPC patients. Higher pretreatment PSS-HN diet, PSS-HN eating, FACT-HN, and EQ-5D index scores were associated with better overall survival (OS) and progression-free (PFS) survival on multivariate analysis. Higher baseline FACT-HN total, functional, physical subscale, and EQ-5D index scores were associated with improved OS and PFS in p16-positive OPC patients but not in p16-negative and non-OPC patients. There was no clinically meaningful difference in QOL/PS between arms. The p16-positive OPC patients had significantly higher QOL/PS than did p16-negative patients. Pretreatment QOL/PS is a significant independent predictor of outcome in locally advanced HNC. Copyright © 2016 Elsevier Inc. All rights reserved.
Functional anatomy of the cheetah (Acinonyx jubatus) forelimb
Hudson, Penny E; Corr, Sandra A; Payne-Davis, Rachel C; Clancy, Sinead N; Lane, Emily; Wilson, Alan M
2011-01-01
Despite the cheetah being the fastest living land mammal, we know remarkably little about how it attains such high top speeds (29 m s−1). Here we aim to describe and quantify the musculoskeletal anatomy of the cheetah forelimb and compare it to the racing greyhound, an animal of similar mass, but which can only attain a top speed of 17 m s−1. Measurements were made of muscle mass, fascicle length and moment arms, enabling calculations of muscle volume, physiological cross-sectional area (PCSA), and estimates of joint torques and rotational velocities. Bone lengths, masses and mid-shaft cross-sectional areas were also measured. Several species differences were observed and have been discussed, such as the long fibred serratus ventralis muscle in the cheetah, which we theorise may translate the scapula along the rib cage (as has been observed in domestic cats), thereby increasing the cheetah's effective limb length. The cheetah's proximal limb contained many large PCSA muscles with long moment arms, suggesting that this limb is resisting large ground reaction force joint torques and therefore is not functioning as a simple strut. Its structure may also reflect a need for control and stabilisation during the high-speed manoeuvring in hunting. The large digital flexors and extensors observed in the cheetah forelimb may be used to dig the digits into the ground, aiding with traction when galloping and manoeuvring. PMID:21332715
Williams, S B; Wilson, A M; Daynes, J; Peckham, K; Payne, R C
2008-01-01
We provide quantitative muscle–tendon architecture and geometry data for the racing greyhound thoracic limb. Muscle mass, belly length, fascicle lengths, pennation angles and moment arms were measured, as were tendon masses and lengths. Maximum isometric force and maximum power were estimated for muscles, and maximum stress and strain were estimated for tendons. Results are compared with other fast quadrupedal runners, and to previously published data in mixed-breed dogs. The implications of the functional adaptations of the greyhound thoracic limb for sprinting performance are discussed. The thoracic limb was found to benefit from a similar proportion of locomotor muscle mass to the pelvic limb, suggesting that it may be used to some extent in propulsion, or alternatively that stabilisation is very important in this animal. Extrinsic muscles, especially latissimus dorsi and pectoralis profundus, were predicted to be powerful and important for generating net positive work during accelerations. Proximal biarticular muscles show specialisation toward preventing collapse of the shoulder and elbow joints to enable strut-like limb function, or some form of dynamic control. Distal muscles did not appear specialised for elastic energy storage, a functional difference to pelvic limb muscles, and the equivalents in horse thoracic limbs. The greyhound thoracic limb appears to possess substantial differences from both that of more ‘sub-maximal specialist’ quadrupeds, and from the greyhound pelvic limb. PMID:19034998
Williams, S B; Wilson, A M; Daynes, J; Peckham, K; Payne, R C
2008-10-01
We provide quantitative muscle-tendon architecture and geometry data for the racing greyhound thoracic limb. Muscle mass, belly length, fascicle lengths, pennation angles and moment arms were measured, as were tendon masses and lengths. Maximum isometric force and maximum power were estimated for muscles, and maximum stress and strain were estimated for tendons. Results are compared with other fast quadrupedal runners, and to previously published data in mixed-breed dogs. The implications of the functional adaptations of the greyhound thoracic limb for sprinting performance are discussed. The thoracic limb was found to benefit from a similar proportion of locomotor muscle mass to the pelvic limb, suggesting that it may be used to some extent in propulsion, or alternatively that stabilisation is very important in this animal. Extrinsic muscles, especially latissimus dorsi and pectoralis profundus, were predicted to be powerful and important for generating net positive work during accelerations. Proximal biarticular muscles show specialisation toward preventing collapse of the shoulder and elbow joints to enable strut-like limb function, or some form of dynamic control. Distal muscles did not appear specialised for elastic energy storage, a functional difference to pelvic limb muscles, and the equivalents in horse thoracic limbs. The greyhound thoracic limb appears to possess substantial differences from both that of more 'sub-maximal specialist' quadrupeds, and from the greyhound pelvic limb.
Kim, Tae Kyung; Lee, H-C; Lee, S G; Han, K-T; Park, E-C
2017-01-01
Introduction Reports of sexual harassment are becoming more frequent in Republic of Korea (ROK) Armed Forces. This study aimed to analyse the impact of sexual harassment on mental health among female military personnel of the ROK Armed Forces. Methods Data from the 2014 Military Health Survey were used. Instances of sexual harassment were recorded as ‘yes’ or ‘no’. Analysis of variance (ANOVA) was carried out to compare Kessler Psychological Distress Scale 10 (K-10) scores. Multiple logistic regression analysis was performed to identify associations between sexual harassment and K-10 scores. Results Among 228 female military personnel, 13 (5.7%) individuals experienced sexual harassment. Multiple logistic regression analysis revealed that sexual harassment had a significantly negative impact on K-10 scores (3.486, p<0.04). Higher K-10 scores among individuals experiencing sexual harassment were identified in the unmarried (including never-married) group (6.761, p<0.04), the short-term military service group (12.014, p<0.03) and the group whose length of service was <2 years (11.067, p<0.02). Conclusions Sexual harassment has a negative impact on mental health. Factors associated with worse mental health scores included service classification and length of service. The results provide helpful information with which to develop measures for minimising the negative psychological effects from sexual harassment and promoting sexual harassment prevention policy. PMID:27084842
NASA Astrophysics Data System (ADS)
Schellhas, Helmut F.; Barnes, Alfonso E.
1982-12-01
Multipurpose surgical CO2 lasers marketed in the USA have been developed to be applicable to a variety of surgical procedures in many surgical fields. They are all suited for endoscopic surgical procedures and can be fitted to all standard surgical microscopes. They all can adjust the focal length of the laser beam to the different standard focal lengths of the surgical microscope which for instance in laryngoscopy is 400 mm and in colposcopy 300 mm. One laser instrument can even change the spot size in a given focal distance which is very advantageous for some microsurgical procedures (Merrimack Laboratories 820). All multipurpose surgical CO2 laser systems provide a multi-articulated surgical arm for free-hand surgery. The surgical arms are cumbersome to use but they are adapted to the surgeons needs with ingenuity. The practicality of the multi-articulated surgical arms depends mostly on the distance of the handpiece from the surgical console which now is also overbridged by the laser tube in most surgical laser system. The spot size of the beam is variable in most handpieces by interchangeable lenses which modify the focal distance of the beam and the power density. Another common feature in all systems is a coaxial He-Ne pilot light which provides a red spot which unfortunately becomes invisible in a bleeding surgical field. Most surgical laser systems have a spacial mode of TEM 00 which is essential for incisional surgery. The continuous mode of beam delivery is used for incisional surgery and also for most endoscopic procedures.
Heaphy, Christopher M.; Gaonkar, Gaurav; Peskoe, Sarah B.; Joshu, Corinne E.; De Marzo, Angelo M.; Lucia, M. Scott; Goodman, Phyllis J.; Lippman, Scott M.; Thompson, Ian M.; Platz, Elizabeth A.; Meeker, Alan K.
2015-01-01
Background Telomeres are repetitive nucleoproteins that help maintain chromosomal stability by inhibiting exonucleolytic degradation, prohibiting inappropriate homologous recombination, and preventing chromosomal fusions by suppressing double-strand break signals. We recently observed that men treated for clinically localized prostate cancer with shorter telomeres in their cancer-associated stromal cells, in combination with greater variation in cancer cell telomere lengths, were significantly more likely to progress to distant metastases and die from their disease. Here, we hypothesized that shorter stromal cell telomere length would be associated with prostate cancer risk at time of biopsy. Methods Telomere-specific fluorescence in situ hybridization (FISH) analysis was performed in normal-appearing stromal, basal epithelial, and luminal epithelial cells in biopsies from men randomized to the placebo arm of the Prostate Cancer Prevention Trial. Prostate cancer cases (N=32) were either detected on a biopsy performed for cause or at the end of the study per trial protocol, and controls (N=50), defined as negative for cancer on an end-of-study biopsy performed per trial protocol (e.g. irrespective of indication), were sampled. Logistic regression was used to estimate the association between mean telomere length of the particular cell populations, cell-to-cell telomere length variability, and risk of prostate cancer. Results Men with short stromal cell telomere lengths (below median) had 2.66 (95% CI 1.04-3.06; p=0.04) times the odds of prostate cancer compared with men who had longer lengths (at or above median). Conversely, we did not observe statistically significant associations for short telomere lengths in normal-appearing basal (OR=2.15, 95% CI 0.86-5.39; p=0.10) or luminal (OR=1.15, 95% CI 0.47-2.80; p=0.77) cells. Conclusions These findings suggest that telomere shortening in normal stromal cells is associated with prostate cancer risk. It is essential to extend and validate these findings, while also identifying the cellular milieu that comprises the subset of cells with short telomeres within the prostate tumor microenvironment. PMID:25893825
Heaphy, Christopher M; Gaonkar, Gaurav; Peskoe, Sarah B; Joshu, Corinne E; De Marzo, Angelo M; Lucia, M Scott; Goodman, Phyllis J; Lippman, Scott M; Thompson, Ian M; Platz, Elizabeth A; Meeker, Alan K
2015-08-01
Telomeres are repetitive nucleoproteins that help maintain chromosomal stability by inhibiting exonucleolytic degradation, prohibiting inappropriate homologous recombination, and preventing chromosomal fusions by suppressing double-strand break signals. We recently observed that men treated for clinically localized prostate cancer with shorter telomeres in their cancer-associated stromal cells, in combination with greater variation in cancer cell telomere lengths, were significantly more likely to progress to distant metastases, and die from their disease. Here, we hypothesized that shorter stromal cell telomere length would be associated with prostate cancer risk at time of biopsy. Telomere-specific fluorescence in situ hybridization (FISH) analysis was performed in normal-appearing stromal, basal epithelial, and luminal epithelial cells in biopsies from men randomized to the placebo arm of the Prostate Cancer Prevention Trial. Prostate cancer cases (N = 32) were either detected on a biopsy performed for cause or at the end of the study per trial protocol, and controls (N = 50), defined as negative for cancer on an end-of-study biopsy performed per trial protocol (e.g., irrespective of indication), were sampled. Logistic regression was used to estimate the association between mean telomere length of the particular cell populations, cell-to-cell telomere length variability, and risk of prostate cancer. Men with short stromal cell telomere lengths (below median) had 2.66 (95% CI 1.04-3.06; P = 0.04) times the odds of prostate cancer compared with men who had longer lengths (at or above median). Conversely, we did not observe statistically significant associations for short telomere lengths in normal-appearing basal (OR = 2.15, 95% CI 0.86-5.39; P= 0 .10) or luminal (OR = 1.15, 95% CI 0.47-2.80; P = 0.77) cells. These findings suggest that telomere shortening in normal stromal cells is associated with prostate cancer risk. It is essential to extend and validate these findings, while also identifying the cellular milieu that comprises the subset of cells with short telomeres within the prostate tumor microenvironment. © 2015 Wiley Periodicals, Inc.
Lee, Dong-Kyu; Kang, Min-Hyeok; Kim, Ji-Won; Kim, Yang-Gon; Park, Ji-Hyuk; Oh, Jae-Seop
2013-01-01
Abdominal strengthening exercises are important for stroke patients; however, there is a lack of research on therapeutic exercises for increasing abdominal muscle activity in stroke patients. We investigated the effects of non-paretic arm exercises using a tubing band on abdominal muscle activity in stroke patients. In total, 18 hemiplegic subjects (13 males, 5 females) were recruited. All subjects performed non-paretic arm exercises involving three different shoulder movements (extension, flexion, and horizontal abduction) using an elastic tubing band. Surface electromyography (EMG) signals were recorded from the rectus abdominis (RA), external oblique (EO), and internal oblique (IO) muscles bilaterally during non-paretic arm exercises. EMG activities of abdominal muscles during non-paretic arm extension and horizontal abduction were increased significantly versus shoulder flexion when subjects performed the arm exercise in a seated position. Muscle activity of the EO was significantly greater in the paretic than the non-paretic side during non-paretic arm extension and horizontal abduction. We suggest that non-paretic arm extension and horizontal abduction exercises using an elastic tubing band may be effective in increasing abdominal muscle activity.
Achromatic self-referencing interferometer
Feldman, M.
1994-04-19
A self-referencing Mach-Zehnder interferometer is described for accurately measuring laser wavefronts over a broad wavelength range (for example, 600 nm to 900 nm). The apparatus directs a reference portion of an input beam to a reference arm and a measurement portion of the input beam to a measurement arm, recombines the output beams from the reference and measurement arms, and registers the resulting interference pattern ([open quotes]first[close quotes] interferogram) at a first detector. Optionally, subportions of the measurement portion are diverted to second and third detectors, which respectively register intensity and interferogram signals which can be processed to reduce the first interferogram's sensitivity to input noise. The reference arm includes a spatial filter producing a high quality spherical beam from the reference portion, a tilted wedge plate compensating for off-axis aberrations in the spatial filter output, and mirror collimating the radiation transmitted through the tilted wedge plate. The apparatus includes a thermally and mechanically stable baseplate which supports all reference arm optics, or at least the spatial filter, tilted wedge plate, and the collimator. The tilted wedge plate is mounted adjustably with respect to the spatial filter and collimator, so that it can be maintained in an orientation in which it does not introduce significant wave front errors into the beam propagating through the reference arm. The apparatus is polarization insensitive and has an equal path length configuration enabling measurement of radiation from broadband as well as closely spaced laser line sources. 3 figures.
Li, Junyan; McWilliams, Anthony B; Jin, Zhongmin; Fisher, John; Stone, Martin H; Redmond, Anthony C; Stewart, Todd D
2015-06-01
Symptomatic leg length inequality accounts for 8.7% of total hip replacement related claims made against the UK National Health Service Litigation authority. It has not been established whether symptomatic leg length inequality patients following total hip replacement have abnormal hip kinetics during gait. Hip kinetics in 15 unilateral total hip replacement patients with symptomatic leg length inequality during gait was determined through multibody dynamics and compared to 15 native hip healthy controls and 15 'successful' asymptomatic unilateral total hip replacement patients. More significant differences from normal were found in symptomatic leg length inequality patients than in asymptomatic total hip replacement patients. The leg length inequality patients had altered functions defined by lower gait velocity, reduced stride length, reduced ground reaction force, decreased hip range of motion, reduced hip moment and less dynamic hip force with a 24% lower heel-strike peak, 66% higher mid-stance trough and 37% lower toe-off peak. Greater asymmetry in hip contact force was also observed in leg length inequality patients. These gait adaptions may affect the function of the implant and other healthy joints in symptomatic leg length inequality patients. This study provides important information for the musculoskeletal function and rehabilitation of symptomatic leg length inequality patients. Copyright © 2015. Published by Elsevier Ltd.
Spigel, David R; Patel, Jyoti D; Reynolds, Craig H; Garon, Edward B; Hermann, Robert C; Govindan, Ramaswamy; Olsen, Mark R; Winfree, Katherine B; Chen, Jian; Liu, Jingyi; Guba, Susan C; Socinski, Mark A; Bonomi, Philip
2015-02-01
Treatment impact on quality of life (QoL) informs treatment management decisions in advanced nonsquamous non-small-cell lung cancer (NS NSCLC). QoL outcomes from the phase III PointBreak trial are reported. Chemonaive patients (n = 939) with stage IIIB/IV nonsquamous non-small-cell lung cancer and Eastern Cooperative Oncology Group performance status 0 to 1 were randomized (1:1) to pemetrexed-carboplatin-bevacizumab (pemetrexed arm) or paclitaxel-carboplatin-bevacizumab (paclitaxel arm). Patients without progressive disease received maintenance pemetrexed-bevacizumab (pemetrexed arm) or bevacizumab (paclitaxel arm). QoL was assessed using Functional Assessment of Cancer Therapy (FACT)-General (FACT-G), FACT-Lung (FACT-L), and FACT/Gynecologic Oncology Group-Neurotoxicity (FACT-Ntx) instruments. Subscale scores, total scores, and trial outcome indices were analyzed using linear mixed-effects models. Post hoc analyses examined the association between baseline FACT scores and overall survival (OS). Mean score differences in change from baseline significantly favored the pemetrexed arm for the neurotoxicity subscale score, FACT-Ntx total scores, and FACT-Ntx trial outcome index. They occurred at cycle 2 (p < 0.001) and persisted through induction cycles 2 to 4 and six maintenance cycles. Investigator-assessed, qualitative, drug-related differences in grade 2 (1.6% versus 10.6%) and grade 3 (0.0% versus 4.1%) sensory neuropathy and grade 3/4 fatigue (10.9% versus 5.0%, p = 0.0012) were observed between the pemetrexed and paclitaxel arms. Baseline FACT-G, FACT-L, and FACT-Ntx scores were significant prognostic factors for OS (p < 0.001). Randomized patients reported similar changes in QoL, except for less change from baseline in neurotoxicity on the pemetrexed arm; investigators reported greater neurotoxicity on the paclitaxel arm and greater fatigue on the pemetrexed arm. Higher baseline FACT scores were favorable prognostic factors for OS.
Fujimori, Takahito; Iwasaki, Motoki; Nagamoto, Yukitaka; Kashii, Masafumi; Takao, Masaki; Sugiura, Tsuyoshi; Yoshikawa, Hideki
2017-02-01
Reliability and agreement study. To assess the reliability of intraoperative 3-dimensional imaging with a mobile C-arm (3D C-arm) equipped with a flat-panel detector. Pedicle screws are widely used in spinal surgery. Postoperative computed tomography (CT) is the most reliable method to detect screw misplacement. Recent advances in imaging devices have enabled surgeons to acquire 3D images of the spine during surgery. However, the reliability of these imaging devices is not known. A total of 203 screws were used in 22 consecutive patients who underwent surgery for scoliosis. Screw position was read twice with a 3D C-arm and twice with CT in a blinded manner by 2 independent observers. Screw positions were classified into 4 categories at every 2 mm and then into 2 simpler categories of acceptable or unacceptable. The degree of agreement with respect to screw positions between the double readings was evaluated by κ value. With unanimous agreement between 2 observers regarding postoperative CT readings considered the gold standard, the sensitivity of the 3D C-arm for determining screw misplacement was calculated. A total 804 readings were performed. For the 4-category classification, the mean κ value for the 2 interobserver readings was 0.52 for the 3D C-arm and 0.46 for CT. For the 2-category classification, the mean κ value for the 2 interobserver readings was 0.80 for the 3D C-arm and 0.66 for CT. The sensitivity, specificity, positive predictive value, and negative predictive value of intraoperative imaging with the 3D C-arm were 70%, 95%, 44%, and 98%, respectively. With respect to screws with perforation ≥4 mm, the sensitivity was 83%. No revision surgery was performed. Intraoperative imaging with a 3D C-arm was reliable for detecting screw misplacement and helpful in decreasing the rate of revision surgery for screw misplacement.
Kootenay Lake Fertilization Experiment; Years 11 and 12, Technical Report 2002-2003.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schindler, E.
This report examines the results from the eleventh and twelfth years (2002 and 2003) of the Kootenay Lake fertilization experiment. Experimental fertilization has occurred with an adaptive management approach since 1992 in order to restore productivity lost as a result of upstream dams. One of the main objectives of the experiment is to restore kokanee (Oncorhynchus nerka) populations, which are a main food source for Gerrard rainbow trout (Oncorhynchus mykiss). Kootenay Lake is located between the Selkirk and Purcell mountains in southeastern British Columbia. It has an area of 395 km2, a maximum depth of 150 m, a mean depthmore » of 94 m, and a water renewal time of approximately two years. The quantity of agricultural grade liquid fertilizer (10-34-0, ammonium polyphosphate and 28-0-0, urea ammonium nitrate) added to Kootenay Lake in 2002 and 2003 was similar to that added from 1992 to 1996. After four years of decreased fertilizer loading (1997 to 2000), results indicated that kokanee populations had declined, and the decision was made to increase the loads again in 2001. The total load of fertilizer in 2002 was 47.1 tonnes of phosphorus and 206.7 tonnes of nitrogen. The total fertilizer load in 2003 was 47.1 tonnes of phosphorus and 240.8 tonnes of nitrogen. Additional nitrogen was added in 2003 to compensate for nitrogen depletion in the epilimnion. The fertilizer was applied to a 10 km stretch in the North Arm from 3 km south of Lardeau to 3 km south of Schroeder Creek. The maximum surface water temperature in 2002, measured on July 22, was 22 C in the North Arm and 21.3 C in the South Arm. In 2003, the maxima were recorded on August 5 at 20.6 C in the North Arm and on September 2 at 19.7 C in the South Arm. The maximum water temperature in the West Arm was 18.7 C on September 2, 2003. Kootenay Lake had oxygen-saturated water throughout the sampling season with values ranging from about 11-16 mg/L in 2002 and 2003. In both years, Secchi depth followed the expected pattern for an oligo-mesotrophic lake of decreasing in May, June, and early July, concurrent with the spring phytoplankton bloom, and clearing again as the summer progressed. Total phosphorus (TP) ranged from 2-11 {micro}g/L in 2002 and 2-21 {micro}g/L in 2003. With average TP values generally in the range of 3-10 {micro}g/L, Kootenay Lake is considered to be an oligotrophic to oligo-mesotrophic lake. Total dissolved phosphorus (TDP) followed the same seasonal trends as TP in 2002 and 2003 and ranged from 2-7 {micro}g/L in 2002 and from 2-10 {micro}g/L in 2003. Total nitrogen (TN) ranged from 90-380 {micro}g/L in 2002 and 100-210 {micro}g/L in 2003. During both the 2002 and 2003 sampling seasons, TN showed an overall decline in concentration with mid-summer and fall increases at some stations, which is consistent with previous years results. Dissolved inorganic nitrogen (DIN) concentrations showed a more pronounced declining trend over the sampling season compared with TN, corresponding to nitrate (the dominant component of DIN) being used by phytoplankton during summer stratification. DIN ranged from 7-176 {micro}g/L in 2002 and from 8-147 {micro}g/L in 2003. During 2003, discrete depth sampling occurred, and a more detailed look at the nitrate concentrations in the epilimnion was undertaken. There was a seasonal decline in nitrate concentrations, which supports the principle of increasing the nitrogen loading and the nitrogen to phosphorus (N:P) ratio during the fertilizer application period. Chlorophyll a (Chl a) concentrations in Kootenay Lake were in the range of 1.4-5.1 {micro}g/L in 2002 and 0.5-4.9 {micro}g/L in 2003. Over the sampling season, Chl a at North Arm stations generally increased in spring corresponding with the phytoplankton bloom, decreased during the summer, and increased again in the fall with mixing of the water column. The trend was similar, but less pronounced, at South Arm stations in these years, and spring Chl a concentrations were lower. During 2002, total algal biomass averaged during June, July and August was lower in the North Arm than the South Arm. This was the first time this occurred since the commencement of the North Arm fertilization experiment. Results in 2002 indicated Kootenay lake continues to be a diatom dominated lake (80 to 89% of the total average biomass). The overall trend observed throughout the 2003 sampling season was one of a slight decline in algal biomass from the North Arm stations towards those in the South Arm. Kootenay Lake continued to be a diatom-dominated lake (76-83% of total average biomass). Synedra spp. and some Asterionella, as in the previous three years, dominated the early biomass increase in 2003, but the peak biomass in July was largely due to Tabellaria.« less
Dependence of paracentric inversion rate on tract length.
York, Thomas L; Durrett, Rick; Nielsen, Rasmus
2007-04-03
We develop a Bayesian method based on MCMC for estimating the relative rates of pericentric and paracentric inversions from marker data from two species. The method also allows estimation of the distribution of inversion tract lengths. We apply the method to data from Drosophila melanogaster and D. yakuba. We find that pericentric inversions occur at a much lower rate compared to paracentric inversions. The average paracentric inversion tract length is approx. 4.8 Mb with small inversions being more frequent than large inversions. If the two breakpoints defining a paracentric inversion tract are uniformly and independently distributed over chromosome arms there will be more short tract-length inversions than long; we find an even greater preponderance of short tract lengths than this would predict. Thus there appears to be a correlation between the positions of breakpoints which favors shorter tract lengths. The method developed in this paper provides the first statistical estimator for estimating the distribution of inversion tract lengths from marker data. Application of this method for a number of data sets may help elucidate the relationship between the length of an inversion and the chance that it will get accepted.
Dependence of paracentric inversion rate on tract length
York, Thomas L; Durrett, Rick; Nielsen, Rasmus
2007-01-01
Background We develop a Bayesian method based on MCMC for estimating the relative rates of pericentric and paracentric inversions from marker data from two species. The method also allows estimation of the distribution of inversion tract lengths. Results We apply the method to data from Drosophila melanogaster and D. yakuba. We find that pericentric inversions occur at a much lower rate compared to paracentric inversions. The average paracentric inversion tract length is approx. 4.8 Mb with small inversions being more frequent than large inversions. If the two breakpoints defining a paracentric inversion tract are uniformly and independently distributed over chromosome arms there will be more short tract-length inversions than long; we find an even greater preponderance of short tract lengths than this would predict. Thus there appears to be a correlation between the positions of breakpoints which favors shorter tract lengths. Conclusion The method developed in this paper provides the first statistical estimator for estimating the distribution of inversion tract lengths from marker data. Application of this method for a number of data sets may help elucidate the relationship between the length of an inversion and the chance that it will get accepted. PMID:17407601
A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging.
Amiri, Shahram; Wilson, David R; Masri, Bassam A; Anglin, Carolyn
2014-07-01
C-arm fluoroscopy is frequently used in clinical applications as a low-cost and mobile real-time qualitative assessment tool. C-arms, however, are not widely accepted for applications involving quantitative assessments, mainly due to the lack of reliable and low-cost position tracking methods, as well as adequate calibration and registration techniques. The solution suggested in this work is a tracked C-arm (TC-arm) which employs a low-cost sensor tracking module that can be retrofitted to any conventional C-arm for tracking the individual joints of the device. Registration and offline calibration methods were developed that allow accurate tracking of the gantry and determination of the exact intrinsic and extrinsic parameters of the imaging system for any acquired fluoroscopic image. The performance of the system was evaluated in comparison to an Optotrak[Formula: see text] motion tracking system and by a series of experiments on accurately built ball-bearing phantoms. Accuracies of the system were determined for 2D-3D registration, three-dimensional landmark localization, and for generating panoramic stitched views in simulated intraoperative applications. The system was able to track the center point of the gantry with an accuracy of [Formula: see text] mm or better. Accuracies of 2D-3D registrations were [Formula: see text] mm and [Formula: see text]. Three-dimensional landmark localization had an accuracy of [Formula: see text] of the length (or [Formula: see text] mm) on average, depending on whether the landmarks were located along, above, or across the table. The overall accuracies of the two-dimensional measurements conducted on stitched panoramic images of the femur and lumbar spine were 2.5 [Formula: see text] 2.0 % [Formula: see text] and [Formula: see text], respectively. The TC-arm system has the potential to achieve sophisticated quantitative fluoroscopy assessment capabilities using an existing C-arm imaging system. This technology may be useful to improve the quality of orthopedic surgery and interventional radiology.
NASA Astrophysics Data System (ADS)
Hart, Ross E.; Bamford, Steven P.; Hayes, Wayne B.; Cardamone, Carolin N.; Keel, William C.; Kruk, Sandor J.; Lintott, Chris J.; Masters, Karen L.; Simmons, Brooke D.; Smethurst, Rebecca J.
2017-12-01
In this paper, we study the morphological properties of spiral galaxies, including measurements of spiral arm number and pitch angle. Using Galaxy Zoo 2, a stellar mass-complete sample of 6222 SDSS spiral galaxies is selected. We use the machine vision algorithm SPARCFIRE to identify spiral arm features and measure their associated geometries. A support vector machine classifier is employed to identify reliable spiral features, with which we are able to estimate pitch angles for half of our sample. We use these machine measurements to calibrate visual estimates of arm tightness, and hence estimate pitch angles for our entire sample. The properties of spiral arms are compared with respect to various galaxy properties. The star formation properties of galaxies vary significantly with arm number, but not pitch angle. We find that galaxies hosting strong bars have spiral arms substantially (4°-6°) looser than unbarred galaxies. Accounting for this, spiral arms associated with many-armed structures are looser (by 2°) than those in two-armed galaxies. In contrast to this average trend, galaxies with greater bulge-to-total stellar mass ratios display both fewer and looser spiral arms. This effect is primarily driven by the galaxy disc, such that galaxies with more massive discs contain more spiral arms with tighter pitch angles. This implies that galaxy central mass concentration is not the dominant cause of pitch angle and arm number variations between galaxies, which in turn suggests that not all spiral arms are governed by classical density waves or modal theories.
Global Modeling of Spur Formation in Spiral Galaxies
NASA Astrophysics Data System (ADS)
Shetty, Rahul; Ostriker, Eve C.
2006-08-01
We investigate the formation of substructure in spiral galaxies using global MHD simulations, including gas self-gravity. Local modeling by Kim & Ostriker previously showed that self-gravity and magnetic fields cause rapid growth of overdensities in spiral arms; differential compression of gas flowing through the arms then results in the formation of sheared structures in the interarms. These sheared structures resemble features described as spurs or feathers in optical and IR observations of many spiral galaxies. Global modeling extends previous local models by including the full effects of curvilinear coordinates, a realistic log-spiral perturbation, self-gravitational contribution from five radial wavelengths of the spiral shock, and variation of density and epicyclic frequency with radius. We show that with realistic Toomre Q-values self-gravity and galactic differential rotation produce filamentary gaseous structures with kiloparsec-scale separations, regardless of the strength-or even presence-of a stellar spiral potential. However, a sufficiently strong spiral potential is required to produce true spurs, consisting of interarm structures emerging from gas concentrations in the main spiral arms. In models where Q is initially constant, filaments due to interarm self-gravity grow mainly in the outer regions, whereas true arm spurs grow only in the inner regions. For models with Q~R, outer regions are intrinsically more stable, so background interarm filaments do not grow, but arm spurs can develop if the spiral potential is strong. Unlike independently growing background filaments, the orientation of arm spurs depends on galactic location. Inside corotation, spurs emanate outward, on the convex side of the arm; outside corotation, spurs grow inward, on the concave side of the arm. Based on orientation and the relation to arm clumps, it is possible to distinguish true spurs that originate as instabilities in the arms from independently growing background filaments. We measure spur spacings of ~3-5 times the Jeans length in the arm and arm clump masses of ~107 Msolar. Finally, we have also studied models without self-gravity, finding that magnetic fields suppress a purely hydrodynamic instability recently proposed by Wada & Koda as a means of growing interarm spurs and feathers. Our models also suggest that magnetic fields are important in preserving grand-design spiral structure when gas in the arms fragments via self-gravity into GMCs.
Innovation in robotic surgery: the Indian scenario.
Deshpande, Suresh V
2015-01-01
Robotics is the science. In scientific words a "Robot" is an electromechanical arm device with a computer interface, a combination of electrical, mechanical, and computer engineering. It is a mechanical arm that performs tasks in Industries, space exploration, and science. One such idea was to make an automated arm - A robot - In laparoscopy to control the telescope-camera unit electromechanically and then with a computer interface using voice control. It took us 5 long years from 2004 to bring it to the level of obtaining a patent. That was the birth of the Swarup Robotic Arm (SWARM) which is the first and the only Indian contribution in the field of robotics in laparoscopy as a total voice controlled camera holding robotic arm developed without any support by industry or research institutes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qin, Kun; Hu, Shuren; Retterer, Scott T.
Our design, fabrication, and characterization of a label-free Mach–Zehnder interferometer (MZI) optical biosensor that incorporates a highly dispersive one-dimensional (1D) photonic crystal in one arm are presented. The sensitivity of this slow light MZI-based sensor scales with the length of the slow light photonic crystal region. The numerically simulated sensitivity of a MZI sensor with a 16 μm long slow light region is 115,000 rad/RIU-cm, which is sevenfold higher than traditional MZI biosensors with millimeter-length sensing regions. Moreover, the experimental bulk refractive index detection sensitivity of 84,000 rad/RIU-cm is realized and nucleic acid detection is also demonstrated.
Measurement of the fluid-velocity profile using a self-mixing superluminescent diode
NASA Astrophysics Data System (ADS)
Rovati, Luigi; Cattini, Stefano; Palanisamy, Nithiyanantham
2011-02-01
A novel optical Doppler velocimeter using a self-mixing superluminescent diode is proposed and demonstrated. The operation mechanism uses the photodiode on the back-face of a commercial superluminescent diode to detect the Doppler signal from an interferometer. Thanks to the low coherence length of the optical source, the position of the measuring volume can be easily moved into the sample under test by adjusting the reference arm length, thus allowing us to measure the velocity profile of the flowing scatterers even in turbid media. The proposed velocimeter is expected to have several industrial as well as medical applications.
NASA Technical Reports Server (NTRS)
Dong, Xiquan; Xi, Baike; Kennedy, Aaron; Minnis, Patrick; Wood, Robert
2013-01-01
A 19-month record of total, and single-layered low (0-3 km), middle (3-6 km), and high (> 6 km) cloud fractions (CFs), and the single-layered marine boundary layer (MBL) cloud macrophysical and microphysical properties has been generated from ground-based measurements taken at the ARM Azores site between June 2009 and December 2010. It documents the most comprehensive and longest dataset on marine cloud fraction and MBL cloud properties to date. The annual means of total CF, and single-layered low, middle, and high CFs derived from ARM radar-lidar observations are 0.702, 0.271, 0.01 and 0.106, respectively. More total and single-layered high CFs occurred during winter, while single-layered low CFs were greatest during summer. The diurnal cycles for both total and low CFs are stronger during summer than during winter. The CFs are bimodally distributed in the vertical with a lower peak at approx. 1 km and higher one between 8 and 11 km during all seasons, except summer, when only the low peak occurs. The persistent high pressure and dry conditions produce more single-layered MBL clouds and fewer total clouds during summer, while the low pressure and moist air masses during winter generate more total and multilayered-clouds, and deep frontal clouds associated with midlatitude cyclones.
Fixture for holding testing transducer
Wagner, T.A.; Engel, H.P.
A fixture for mounting an ultrasonic transducer against the end of a threaded bolt or stud to test the same for flaws. A base means threadedly secured to the side of the bolt has a rotating ring thereon. A post rising up from the ring (parallel to the axis of the workpiece) pivotally mounts a variable length cross arm, on the inner end of which is mounted the transducer. A spring means acts between the cross arm and the base to apply the testing transducer against the workpiece at a constant pressure. The device maintains constant for successive tests the radial and circumferential positions of the testing transducer and its contact pressure against the end of the workpiece.
Fixture for holding testing transducer
Wagner, Thomas A.; Engel, Herbert P.
1984-01-01
A fixture for mounting an ultrasonic transducer against the end of a threaded bolt or stud to test the same for flaws. A base means threadedly secured to the side of the bolt has a rotating ring thereon. A post rising up from the ring (parallel to the axis of the workpiece) pivotally mounts a variable length cross arm, on the inner end of which is mounted the transducer. A spring means acts between the cross arm and the base to apply the testing transducer against the workpiece at a constant pressure. The device maintains constant for successive tests the radial and circumferential positions of the testing transducer and its contact pressure against the end of the workpiece.
Miniaturized fiber-optic Michelson-type interferometric sensors
NASA Technical Reports Server (NTRS)
Murphy, Kent A.; Miller, William V., III; Tran, Tuan A.; Vengsarkar, Ashish M.; Claus, Richard O.
1991-01-01
A novel, miniaturized Michelson-type fiber-optic interferometric sensor that is relatively insensitive to temperature drifts is presented. A fused-biconical tapered coupler is cleaved immediately after the coupled length and polished down to the region of the fused cladding, but short of the interaction region. The end of one core is selectively coated with a reflective surface and is used as the reference arm; the other core serves as the sensing arm. The detection of surface acoustic waves, microdisplacements, and magnetic fields is reported. The sensor is shown to be highly stable in comparison to a classic homodyne, uncompensated Michelson interferometer, and signal-to-noise ratios of 65 dB have been obtained.
Zickler, D; de Lares, L; Moreau, P J; Leblon, G
1985-01-01
The recessive meiotic mutant spo44 of Sordaria macrospora, with 90% ascospore abortion, exhibits striking effects on recombination (67% decrease), irregular segregation of the almost unpaired homologues, and a decrease in chiasma frequency in the few cases where bivalents are formed. Three-dimensional reconstructions of ten prophase nuclei indicate that pairing, as judged by the absence of fully formed synaptonemal complexes (SC), is not achieved although lateral elements (LE) assemble. The pairing failure is attributable to defects in the alignment of homologous chromosomes. The leptotene alignment seen in the wild type before SC formation was not observed in the spo44 nuclei. Dense material, considered to be precursor of SC central elements, was found scattered among the LE in two nuclei. The behaviour of spo44 substantiates the hypothesis that chromosome matching and SC formation are separable events. - The total length of the LE in the mutant is the same as in the wild type, but due to variable numbers and length of the individual LE, homologues cannot be lined up. Light microscopic observations indicate that the irregular length and number of LE is due to extensive chromosome breakage. The wild-type function corresponding to spo44 is required for both LE integrity and chromosome matching. Reconstructions of heterozygous nuclei reveal the presence of a supernumerary nucleolar organizer in one arm of chromosome 7. It is suggested that rDNA has been inserted into a gene whose function is involved in pairing or into a controlling sequence that interacts with the pairing process.
Richardson, Ashley K; Mitchell, Andrew C S; Hughes, Gerwyn
2017-02-01
This study aimed to examine the effect of the impact point on the golf ball on the horizontal launch angle and side spin during putting with a mechanical putting arm and human participants. Putts of 3.2 m were completed with a mechanical putting arm (four putter-ball combinations, total of 160 trials) and human participants (two putter-ball combinations, total of 337 trials). The centre of the dimple pattern (centroid) was located and the following variables were measured: distance and angle of the impact point from the centroid and surface area of the impact zone. Multiple regression analysis was conducted to identify whether impact variables had significant associations with ball roll variables, horizontal launch angle and side spin. Significant associations were identified between impact variables and horizontal launch angle with the mechanical putting arm but this was not replicated with human participants. The variability caused by "dimple error" was minimal with the mechanical putting arm and not evident with human participants. Differences between the mechanical putting arm and human participants may be due to the way impulse is imparted on the ball. Therefore it is concluded that variability of impact point on the golf ball has a minimal effect on putting performance.
Zhang, Da-song; Chu, Jian
2014-01-01
Based on the 6D constraints of momentum change rate (CMCR), this paper puts forward a real-time and full balance maintenance method for the humanoid robot during high-speed movement of its 7-DOF arm. First, the total momentum formula for the robot's two arms is given and the momentum change rate is defined by the time derivative of the total momentum. The author also illustrates the idea of full balance maintenance and analyzes the physical meaning of 6D CMCR and its fundamental relation to full balance maintenance. Moreover, discretization and optimization solution of CMCR has been provided with the motion constraint of the auxiliary arm's joint, and the solving algorithm is optimized. The simulation results have shown the validity and generality of the proposed method on the full balance maintenance in the 6 DOFs of the robot body under 6D CMCR. This method ensures 6D dynamics balance performance and increases abundant ZMP stability margin. The resulting motion of the auxiliary arm has large abundance in joint space, and the angular velocity and the angular acceleration of these joints lie within the predefined limits. The proposed algorithm also has good real-time performance. PMID:24883404
Verma, S K; Singh, P K; Agrawal, D; Sinha, S; Gupta, D; Satyarthee, G D; Sharma, B S
2016-12-01
There is a relatively high incidence of screw misplacement during spinal instrumentation due to distortion of normal anatomy following spinal trauma. The O-arm is the next-generation spinal navigation tool that provides intraoperative 3-D imaging and navigation for spine surgeries. To evaluate and compare the use of O-arm as compared to C-arm for spinal trauma in a Level I trauma center in India. In this retrospective study over 3 years (July 2010-April 2013), All patients of spinal injury who underwent spinal instrumentation were divided into O-arm group and C-arm group. Accuracy of screw placement was assessed during each surgery in both groups. A total of 587 patients were evaluated during the study period. There were 278 patients in O-arm group and 309 patients in C-arm group. Both groups were well matched in mean age (27.7 vs. 28.9 years), ASIA grades, and level of injury. The number of screws placed was significantly higher in the C-arm group as compared to the O-arm group (2173 vs. 1720). However, the O-arm group had significantly less screw malplacement rate of 0.93% (n = 16) as compared to malplacement rate in C-arm group of 8.79% (n = 191, p < 0.05). Use of O-arm imaging system ensures accurate screw placement and dramatically decreases screw malplacement rate, thus providing better patient safety. Its use is especially beneficial in academic and teaching centers where novice surgeons can attain results equivalent to that of experts in spinal instrumentation.
[Incidence and severity of the digestive system diseases in the armed forces of Ukraine].
Rozhkov, H S
2012-01-01
The paper presents an analysis of the level and structure of morbidity Armed Forces of Ukraine diseases of the digestive system. The highest rates of total incidence of disease in the class XI 2008-2011, recorded among conscripts, the lowest--in the military under the contract.
Ca2+-Induced Rigidity Change of the Myosin VIIa IQ Motif-Single α Helix Lever Arm Extension.
Li, Jianchao; Chen, Yiyun; Deng, Yisong; Unarta, Ilona Christy; Lu, Qing; Huang, Xuhui; Zhang, Mingjie
2017-04-04
Several unconventional myosins contain a highly charged single α helix (SAH) immediately following the calmodulin (CaM) binding IQ motifs, functioning to extend lever arms of these myosins. How such SAH is connected to the IQ motifs and whether the conformation of the IQ motifs-SAH segments are regulated by Ca 2+ fluctuations are not known. Here, we demonstrate by solving its crystal structure that the predicted SAH of myosin VIIa (Myo7a) forms a stable SAH. The structure of Myo7a IQ5-SAH segment in complex with apo-CaM reveals that the SAH sequence can extend the length of the Myo7a lever arm. Although Ca 2+ -CaM remains bound to IQ5-SAH, the Ca 2+ -induced CaM binding mode change softens the conformation of the IQ5-SAH junction, revealing a Ca 2+ -induced lever arm flexibility change for Myo7a. We further demonstrate that the last IQ motif of several other myosins also binds to both apo- and Ca 2+ -CaM, suggesting a common Ca 2+ -induced conformational regulation mechanism. Copyright © 2017 Elsevier Ltd. All rights reserved.
Finger muscle attachments for an OpenSim upper-extremity model.
Lee, Jong Hwa; Asakawa, Deanna S; Dennerlein, Jack T; Jindrich, Devin L
2015-01-01
We determined muscle attachment points for the index, middle, ring and little fingers in an OpenSim upper-extremity model. Attachment points were selected to match both experimentally measured locations and mechanical function (moment arms). Although experimental measurements of finger muscle attachments have been made, models differ from specimens in many respects such as bone segment ratio, joint kinematics and coordinate system. Likewise, moment arms are not available for all intrinsic finger muscles. Therefore, it was necessary to scale and translate muscle attachments from one experimental or model environment to another while preserving mechanical function. We used a two-step process. First, we estimated muscle function by calculating moment arms for all intrinsic and extrinsic muscles using the partial velocity method. Second, optimization using Simulated Annealing and Hooke-Jeeves algorithms found muscle-tendon paths that minimized root mean square (RMS) differences between experimental and modeled moment arms. The partial velocity method resulted in variance accounted for (VAF) between measured and calculated moment arms of 75.5% on average (range from 48.5% to 99.5%) for intrinsic and extrinsic index finger muscles where measured data were available. RMS error between experimental and optimized values was within one standard deviation (S.D) of measured moment arm (mean RMS error = 1.5 mm < measured S.D = 2.5 mm). Validation of both steps of the technique allowed for estimation of muscle attachment points for muscles whose moment arms have not been measured. Differences between modeled and experimentally measured muscle attachments, averaged over all finger joints, were less than 4.9 mm (within 7.1% of the average length of the muscle-tendon paths). The resulting non-proprietary musculoskeletal model of the human fingers could be useful for many applications, including better understanding of complex multi-touch and gestural movements.