40 CFR 142.16 - Special primacy requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... coliform or E. coli testing on a total coliform-positive sample)—A description of how the State will determine whether it is appropriate to waive fecal coliform or E. coli testing on a total coliform-positive... where allowed in State programs. (1) Approve an alternative to the E. coli levels that trigger...
40 CFR 142.63 - Variances and exemptions from the maximum contaminant level for total coliforms.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) EPA has stayed the effective date of this section relating to the total coliform MCL of § 141.63(a) of this chapter for systems that demonstrate to the State that the violation of the total coliform MCL is...
Abass, Kabila; Ganle, John Kuumuori; Adaborna, Eric
2016-04-01
Peri-urban vegetable farming in Ghana is an important livelihood activity for an increasing number of people. However, increasing quality and public health concerns have been raised, partly because freshwater availability for irrigation purposes is a major constraint. This paper investigated on-farm vegetable contamination and potential health risks using samples of lettuce, spring onions and cabbage randomly selected from 18 vegetable farms in peri-urban Kumasi, Ghana. Vegetable samples were tested for total coliform, fecal coliform, Escherichia coli and Salmonella spp. bacteria contamination using the Most Probable Number method. Results show high contamination levels of total and fecal coliforms, and Escherichia coli bacteria in all 18 vegetable samples. The mean total coliform/100 ml concentration for spring onions, lettuce and cabbage were 9.15 × 10(9), 4.7 × 10(7) and 8.3 × 10(7) respectively. The mean fecal coliform concentration for spring onions, lettuce and cabbage were also 1.5 × 10(8), 4.15 × 10(7) and 2.15 × 10(7) respectively, while the mean Escherichia coli bacteria contamination for spring onions, lettuce and cabbage were 1.4 × 10(8), 2.2 × 10(7) and 3.2 × 10(7) respectively. The level of total coliform, fecal coliform and Escherichia coli bacteria contamination in all the vegetable samples however declined as the distance between the main water source (Wiwi River) and farms increases. Nonetheless, all contamination levels were well above acceptable standards, and could therefore pose serious public health risks to consumers. Increased education and supervision of farmers, as well as public health and food hygiene education of consumers, are critical to reducing on-farm vegetable contamination and the health risks associated with consumption of such vegetables.
40 CFR 141.63 - Maximum contaminant levels (MCLs) for microbiological contaminants.
Code of Federal Regulations, 2011 CFR
2011-07-01
... repeat sample or E. coli-positive repeat sample, or any total coliform-positive repeat sample following a fecal coliform-positive or E. coli-positive routine sample constitutes a violation of the MCL for total...
40 CFR 141.63 - Maximum contaminant levels (MCLs) for microbiological contaminants.
Code of Federal Regulations, 2010 CFR
2010-07-01
... repeat sample or E. coli-positive repeat sample, or any total coliform-positive repeat sample following a fecal coliform-positive or E. coli-positive routine sample constitutes a violation of the MCL for total...
Maheux, Andrée F; Bouchard, Sébastien; Bérubé, Ève; Bergeron, Michel G
2017-06-01
The MI, Chromocult ® coliform, and Compass CC chromogenic culture-based methods used to assess water quality by the detection of Escherichia coli and total coliforms were compared in terms of their specificity and sensitivity, using 16S rRNA sequencing for colony identification. A sewage water sample was divided in 2-μL subsamples for testing by all three culture-based methods. All growing colonies were harvested and subjected to 16S rRNA sequencing. Test results showed that all E. coli colonies were correctly identified by all three methods, for a specificity and a sensitivity of 100%. However, for the total coliform detection, the MI agar, Chromocult ® coliform agar, and Compass CC agar were specific for only 69.2% (9/13), 47.2% (25/53), and 40.5% (17/42), whereas sensitive for 97.8% (45/46), 97.5% (39/40), and 85.7% (24/28), respectively. Thus, given the low level of specificity of these methods for the detection of total coliforms, confirming the identity of total coliform colonies could help to take public health decisions, in particular for cities connected to a public drinking water distribution system since the growth of few putative total coliform colonies on chromogenic agar is problematic and can lead to unnecessary and costly boiling notices from public health authorities.
Khush, Ranjiv S.; Arnold, Benjamin F.; Srikanth, Padma; Sudharsanam, Suchithra; Ramaswamy, Padmavathi; Durairaj, Natesan; London, Alicia G.; Ramaprabha, Prabhakar; Rajkumar, Paramasivan; Balakrishnan, Kalpana; Colford Jr., John M.
2013-01-01
In this large-scale longitudinal study conducted in rural Southern India, we compared a presence/absence hydrogen sulfide (H2S) test with quantitative assays for total coliforms and Escherichia coli as measures of water quality, health risk, and water supply vulnerability to microbial contamination. None of the three indicators showed a significant association with child diarrhea. The presence of H2S in a water sample was associated with higher levels of total coliform species that may have included E. coli but that were not restricted to E. coli. In addition, we observed a strong relationship between the percent positive H2S test results and total coliform levels among water source samples (R2 = 0.87). The consistent relationships between H2S and total coliform levels indicate that presence/absence of H2S tests provide a cost-effective option for assessing both the vulnerability of water supplies to microbial contamination and the results of water quality management and risk mitigation efforts. PMID:23716404
Hong, Huachang; Qiu, Jianwen; Liang, Yan
2010-01-01
The Pearl River Delta (PRD) is one of the most developed and densely populated regions in China. Quantifying the amount of pathogens in the source of drinking water is important for improving water quality. We collected water samples from six major water storage reservoirs in the PRD region in both wet and dry seasons in 2006. Results showed that external environmental factors, such as precipitation, location, as well as the internal environmental factors, i.e., physicochemical properties of the water, were closely related with the distribution of coliforms. Seasonally, the coliform bacterial concentrations in wet season were one to two orders of magnitude greater than those in dry season. Spatially, coliform bacterial levels in reservoirs near urban and industrial areas were significantly higher (p < 0.05) than those in remote areas. Correlation analyses showed that the levels of coliforms had close relationships with pH, temperature, suspended solid, organic and inorganic nutrients in water. Principal components analysis further demonstrated that total coliforms in the reservoirs were closely related with water physicochemical properties, while fecal coliforms were more associated with external input brought in by seasonal runoff.
Full-scale studies of factors related to coliform regrowth in drinking water.
LeChevallier, M W; Welch, N J; Smith, D B
1996-07-01
An 18-month survey of 31 water systems in North America was conducted to determine the factors that contribute to the occurrence of coliform bacteria in drinking water. The survey included analysis of assimilable organic carbon (AOC), coliforms, disinfectant residuals, and operational parameters. Coliform bacteria were detected in 27.8% of the 2-week sampling periods and were associated with the following factors: filtration, temperature, disinfectant type and disinfectant level, AOC level, corrosion control, and operational characteristics. Four systems in the study that used unfiltered surface water accounted for 26.6% of the total number of bacterial samples collected but 64.3% (1,013 of 1,576) of the positive coliform samples. The occurrence of coliform bacteria was significantly higher when water temperatures were > 15 degrees C. For filtered systems that used free chlorine, 0.97% of 33,196 samples contained coliform bacteria, while 0.51% of 35,159 samples from chloraminated systems contained coliform bacteria. The average density of coliform bacteria was 35 times higher in free-chlorinated systems than in chloraminated water (0.60 CFU/100 ml for free-chlorinated water compared with 0.017 CFU/100 ml for chloraminated water). Systems that maintained dead-end free chlorine levels of < 0.2 mg/liter or monochloramine levels of < 0.5 mg/liter had substantially more coliform occurrences than systems that maintained higher disinfectant residuals. Free-chlorinated systems with AOC levels greater than 100 micrograms/liter had 82% more coliform-positive samples and 19 times higher coliform levels than free-chlorinated systems with average AOC levels less than 99 micrograms/liter. Systems that maintained a phosphate-based corrosion inhibitor and limited the amount of unlined cast iron pipe had fewer coliform bacteria. Several operational characteristics of the treatment process or the distribution system were also associated with increased rates of coliform occurrence. The study concludes that the occurrence of coliform bacteria within a distribution system is dependent upon a complex interaction of chemical, physical, operational, and engineering parameters. No one factor could account for all of the coliform occurrences, and one must consider all of the parameters described above in devising a solution to the regrowth problem.
Full-scale studies of factors related to coliform regrowth in drinking water.
LeChevallier, M W; Welch, N J; Smith, D B
1996-01-01
An 18-month survey of 31 water systems in North America was conducted to determine the factors that contribute to the occurrence of coliform bacteria in drinking water. The survey included analysis of assimilable organic carbon (AOC), coliforms, disinfectant residuals, and operational parameters. Coliform bacteria were detected in 27.8% of the 2-week sampling periods and were associated with the following factors: filtration, temperature, disinfectant type and disinfectant level, AOC level, corrosion control, and operational characteristics. Four systems in the study that used unfiltered surface water accounted for 26.6% of the total number of bacterial samples collected but 64.3% (1,013 of 1,576) of the positive coliform samples. The occurrence of coliform bacteria was significantly higher when water temperatures were > 15 degrees C. For filtered systems that used free chlorine, 0.97% of 33,196 samples contained coliform bacteria, while 0.51% of 35,159 samples from chloraminated systems contained coliform bacteria. The average density of coliform bacteria was 35 times higher in free-chlorinated systems than in chloraminated water (0.60 CFU/100 ml for free-chlorinated water compared with 0.017 CFU/100 ml for chloraminated water). Systems that maintained dead-end free chlorine levels of < 0.2 mg/liter or monochloramine levels of < 0.5 mg/liter had substantially more coliform occurrences than systems that maintained higher disinfectant residuals. Free-chlorinated systems with AOC levels greater than 100 micrograms/liter had 82% more coliform-positive samples and 19 times higher coliform levels than free-chlorinated systems with average AOC levels less than 99 micrograms/liter. Systems that maintained a phosphate-based corrosion inhibitor and limited the amount of unlined cast iron pipe had fewer coliform bacteria. Several operational characteristics of the treatment process or the distribution system were also associated with increased rates of coliform occurrence. The study concludes that the occurrence of coliform bacteria within a distribution system is dependent upon a complex interaction of chemical, physical, operational, and engineering parameters. No one factor could account for all of the coliform occurrences, and one must consider all of the parameters described above in devising a solution to the regrowth problem. PMID:8779557
40 CFR 141.52 - Maximum contaminant level goals for microbiological contaminants.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Giardia lamblia zero (2) Viruses zero (3) Legionella zero (4) Total coliforms (including fecal) zero coliforms and Escherichia coli (5) Cryptosporidium zero (6) Escherichia coli (E. coli) zero (b) The MCLG...
40 CFR 141.52 - Maximum contaminant level goals for microbiological contaminants.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Giardia lamblia zero (2) Viruses zero (3) Legionella zero (4) Total coliforms (including fecal) zero coliforms and Escherichia coli (5) Cryptosporidium zero (6) Escherichia coli (E. coli) zero (b) The MCLG...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-21
... Total Coliform Total Coliform 9221 A, B, C..... 9221 A, B, C..... Fermentation Technique. Total Coliform... Methodology category Method SM 22nd Edition \\28\\ Total Coliforms Lactose Fermentation Standard Total 9221 B.1, B.2 Methods. Coliform Fermentation Technique. Enzyme Substrate Colilert[supreg].... 9223 B Methods...
40 CFR 141.52 - Maximum contaminant level goals for microbiological contaminants.
Code of Federal Regulations, 2010 CFR
2010-07-01
... lamblia zero (2) Viruses zero (3) Legionella zero (4) Total coliforms (including fecal coliforms and Escherichia coli) zero. (5) Cryptosporidium zero. [54 FR 27527, 27566, June 29, 1989; 55 FR 25064, June 19...
40 CFR 141.52 - Maximum contaminant level goals for microbiological contaminants.
Code of Federal Regulations, 2012 CFR
2012-07-01
... lamblia zero (2) Viruses zero (3) Legionella zero (4) Total coliforms (including fecal coliforms and Escherichia coli) zero. (5) Cryptosporidium zero. [54 FR 27527, 27566, June 29, 1989; 55 FR 25064, June 19...
40 CFR 141.52 - Maximum contaminant level goals for microbiological contaminants.
Code of Federal Regulations, 2011 CFR
2011-07-01
... lamblia zero (2) Viruses zero (3) Legionella zero (4) Total coliforms (including fecal coliforms and Escherichia coli) zero. (5) Cryptosporidium zero. [54 FR 27527, 27566, June 29, 1989; 55 FR 25064, June 19...
Mellerup, Anders; Ståhl, Marie
2015-01-01
The aim of this article was to define the sampling level and method combination that captures antibiotic resistance at pig herd level utilizing qPCR antibiotic resistance gene quantification and culture-based quantification of antibiotic resistant coliform indicator bacteria. Fourteen qPCR assays for commonly detected antibiotic resistance genes were developed, and used to quantify antibiotic resistance genes in total DNA from swine fecal samples that were obtained using different sampling and pooling methods. In parallel, the number of antibiotic resistant coliform indicator bacteria was determined in the same swine fecal samples. The results showed that the qPCR assays were capable of detecting differences in antibiotic resistance levels in individual animals that the coliform bacteria colony forming units (CFU) could not. Also, the qPCR assays more accurately quantified antibiotic resistance genes when comparing individual sampling and pooling methods. qPCR on pooled samples was found to be a good representative for the general resistance level in a pig herd compared to the coliform CFU counts. It had significantly reduced relative standard deviations compared to coliform CFU counts in the same samples, and therefore differences in antibiotic resistance levels between samples were more readily detected. To our knowledge, this is the first study to describe sampling and pooling methods for qPCR quantification of antibiotic resistance genes in total DNA extracted from swine feces. PMID:26114765
Black, L E; Brion, G M; Freitas, S J
2007-06-01
Predicting the presence of enteric viruses in surface waters is a complex modeling problem. Multiple water quality parameters that indicate the presence of human fecal material, the load of fecal material, and the amount of time fecal material has been in the environment are needed. This paper presents the results of a multiyear study of raw-water quality at the inlet of a potable-water plant that related 17 physical, chemical, and biological indices to the presence of enteric viruses as indicated by cytopathic changes in cell cultures. It was found that several simple, multivariate logistic regression models that could reliably identify observations of the presence or absence of total culturable virus could be fitted. The best models developed combined a fecal age indicator (the atypical coliform [AC]/total coliform [TC] ratio), the detectable presence of a human-associated sterol (epicoprostanol) to indicate the fecal source, and one of several fecal load indicators (the levels of Giardia species cysts, coliform bacteria, and coprostanol). The best fit to the data was found when the AC/TC ratio, the presence of epicoprostanol, and the density of fecal coliform bacteria were input into a simple, multivariate logistic regression equation, resulting in 84.5% and 78.6% accuracies for the identification of the presence and absence of total culturable virus, respectively. The AC/TC ratio was the most influential input variable in all of the models generated, but producing the best prediction required additional input related to the fecal source and the fecal load. The potential for replacing microbial indicators of fecal load with levels of coprostanol was proposed and evaluated by multivariate logistic regression modeling for the presence and absence of virus.
Influence of Coliform Source on Evaluation of Membrane Filters
Brodsky, M. H.; Schiemann, D. A.
1975-01-01
Four brands of membrane filters were examined for total and fecal coliform recovery performance by two experimental approaches. Using diluted EC broth cultures of water samples, Johns-Manville filters were superior to Sartorius filters for fecal coliform but equivalent for total coliform recovery. Using river water samples, Johns-Manville filters were superior to Sartorius filters for total coliform but equivalent for fecal coliform recovery. No differences were observed between Johns-Manville and Millipore or Millipore and Sartorius filters for total or fecal coliform recoveries using either approach, nor was any difference observed between Millipore and Gelman filters for fecal coliform recovery from river water samples. These results indicate that the source of the coliform bacteria has an important influence on the conclusions of membrane filter evaluation studies. PMID:1106318
Code of Federal Regulations, 2014 CFR
2014-07-01
... per month, the system has two or more total coliform-positive samples in the same month. (iii) The... second Level 1 trigger as defined in paragraph (a)(1) of this section, within a rolling 12-month period...) Level 1 treatment technique triggers. (i) For systems taking 40 or more samples per month, the system...
Code of Federal Regulations, 2013 CFR
2013-07-01
... per month, the system has two or more total coliform-positive samples in the same month. (iii) The... second Level 1 trigger as defined in paragraph (a)(1) of this section, within a rolling 12-month period...) Level 1 treatment technique triggers. (i) For systems taking 40 or more samples per month, the system...
Buhr, R J; Berrang, M E; Cason, J A
2003-10-01
Genetically feathered and featherless sibling broilers selected for matched BW were killed, scalded, and defeathered to determine the consequences of feathers and empty feather follicles on the recovery of bacteria from carcass breast skin. In trial 1, the vents of all carcasses were plugged and sutured before scalding to prevent the expulsion of cloacal contents during picking. In trial 2, half of the carcasses had their vents plugged and sutured. Immediately after defeathering, breast skin was aseptically removed, and bacteria associated with it were enumerated. In trial 1, the levels of bacteria recovered did not differ between feathered and featherless carcasses: Campylobacter log10 1.4 cfu/mL of rinse, coliform log10 1.8, Escherichia coli log10 1.6, and total aerobic bacteria log10 3.1. In trial 2, the carcasses that had vents plugged and sutured had lower levels of all four types of bacteria (differences of Campylobacter log10 0.7 cfu/mL, coliform log10 1.8, E. coli log10 1.7, and total aerobic bacteria log10 0.5) than those carcasses with open vents. The lower levels of bacteria recovered from carcasses with the vents plugged and sutured during picking enabled detection of small but significant differences between feathered and featherless carcasses. The level of coliform and E. coli recovered was slightly higher by log10 0.7 cfu for feathered carcasses, but featherless carcasses had marginally higher levels of total aerobic bacteria by log10 0.4 cfu. Feathered and featherless carcasses with open vents during picking did not differ in the levels of recovery of coliform, E. coli, and total aerobic bacteria from breast skin.
Ribeiro, E B; Bastos, L S; Galeno, L S; Mendes, R S; Garino, F; Carvalho-Neta, R N F; Costa, F N
2016-12-15
This study was conducted to evaluate the use of biochemical biomarkers and microbiological analysis to identify levels of oyster contamination at different ports in São Luís Island (Maranhão), Brazil. Oysters were analyzed for total coliforms, thermotolerant coliforms, Escherichia coli and Aeromonas spp. In addition, tissue was removed from the digestive gland to determine the glutathione-S-transferase (GST) and catalase (CAT) activity. The highest percentage of microbiological contamination of oyster samples occurred during the rainy season. The activity of GST and catalase in oysters was also higher in the rainy season, coinciding with the greatest abundance of total and thermotolerant coliforms. Among the prospective biomarkers, GST showed the best results for identification of areas with higher levels of contamination. Copyright © 2016 Elsevier Ltd. All rights reserved.
Korir, Robert Cheruiyot; Parveen, Salina; Hashem, Fawzy; Bowers, John
2016-06-01
The aim of this study was to investigate the microbiological quality of six types of fresh produce obtained from three retail stores located on the Eastern Shore of Maryland, USA. A total of 414 samples representing basil, cilantro, lettuce, scallion, spinach, and parsley were analyzed for total aerobic bacteria (APC), total coliforms, Escherichia coli, and three pathogenic bacteria (E. coli O157:H7, Listeria monocytogenes, and Salmonella), using standard methods. Presumptive pathogenic isolates were confirmed using BAX Polymerase Chain Reaction. Total aerobic populations varied widely between samples, while 38.41% were positive for total coliforms and only 10.15% for E. coli. Median abundance (log CFU/g) of total coliforms and E. coli were less than the limit of detection and that of APC ranged from 5.78 to 6.61 over the six produce types. There was a statistically significant difference in prevalence of total coliforms among the retail stores, but not for abundance of APC or prevalence of E. coli. E. coli O157:H7 and L. monocytogenes were detected in one spinach sample each, while one parsley and one cilantro sample were positive for Salmonella. There were no statistically significant differences in microbiological quality among produce types. Although the results of this study provided some indices of sanitary and/or spoilage level, no relationship was observed among the total aerobic bacteria, total coliforms, E. coli, and the presence of pathogenic bacteria in the samples tested. Copyright © 2015 Elsevier Ltd. All rights reserved.
Akhter, Asma; Imran, Mohd; Akhter, Firoz
2014-01-01
The distribution of resistance to ampicillin, chloramphenicol, sulfonamides, tetracycline, and streptomycin among coliform in the Gomti river water samples was investigated. The coliform populations were isolated on Mac Conky and eosin methylene blue (EMB) agar plates supplemented with antibiotics. The incidence of resistance among the coliform population varied considerably in different drug and water sampling sites. Coliform bacteria showed lower drug resistant viable count in sampling site-III (receiving treated wastewater) as compared to more polluted site-I and site-II. Viable count of coliform population obtained on both medium was recorded higher against erythromycin from sampling site-III. Lower viable count of coliforms was recorded against tetracycline in site-II and III. Similar resistance pattern was obtained in the frequency of E. coli and Enterobacter species from all the three sampling sites. Percentage of antibiotic resistant E. coli was observed higher than Enterobacter spp among the total coliforms against all antibiotics tested without Erythromycin and penicillin in site-I and II respectively. Isolates of E. coli and Enterobacter spp. showed their tolerance level (MIC) in the range of 2-100 against the antibiotics tested. Maximum number of isolates of both genus exhibited their MICs at lower concentration range 2-5µg/ml against ciprofloxacin, tetracyclin and amoxycillin. EMB - Eosin methylene blue, IMViC tests - Indole, Methyl Red, Voges Proskauer and Citrate Utilization Tests, MIC - Minimum inhibitory concentration.
Akhter, Asma; Imran, Mohd; Akhter, Firoz
2014-01-01
The distribution of resistance to ampicillin, chloramphenicol, sulfonamides, tetracycline, and streptomycin among coliform in the Gomti river water samples was investigated. The coliform populations were isolated on Mac Conky and eosin methylene blue (EMB) agar plates supplemented with antibiotics. The incidence of resistance among the coliform population varied considerably in different drug and water sampling sites. Coliform bacteria showed lower drug resistant viable count in sampling site-III (receiving treated wastewater) as compared to more polluted site-I and site-II. Viable count of coliform population obtained on both medium was recorded higher against erythromycin from sampling site-III. Lower viable count of coliforms was recorded against tetracycline in site-II and III. Similar resistance pattern was obtained in the frequency of E. coli and Enterobacter species from all the three sampling sites. Percentage of antibiotic resistant E. coli was observed higher than Enterobacter spp among the total coliforms against all antibiotics tested without Erythromycin and penicillin in site-I and II respectively. Isolates of E. coli and Enterobacter spp. showed their tolerance level (MIC) in the range of 2-100 against the antibiotics tested. Maximum number of isolates of both genus exhibited their MICs at lower concentration range 2-5µg/ml against ciprofloxacin, tetracyclin and amoxycillin. Abbreviations EMB - Eosin methylene blue, IMViC tests - Indole, Methyl Red, Voges Proskauer and Citrate Utilization Tests, MIC - Minimum inhibitory concentration. PMID:24966515
Escherichia coli, total coliform, and fecal coliform data were collected from two wastewater treatment facilities, a subsurface constructed wetlands, and the receiving stream. Results are presented from individual wastewater treatment process streams, final effluent and river sit...
Revised Total Coliform Rule Assessments and Corrective Actions
EPA has developed the Revised Total Coliform Rule Assessment and Corrective Actions Guidance Manual for public water systems (e.g., owners and operators) to assist in complying with the requirements of the Revised Total Coliform Rule.
Whitehead, Paul; Bussi, Gianbattista; Hossain, Mohammed Abed; Dolk, Michaela; Das, Partho; Comber, Sean; Peters, Rebecca; Charles, Katrina J; Hope, Rob; Hossain, Md Sarwar
2018-08-01
River water quality in rapidly urbanising Asian cities threatens to damage the resource base on which human health, economic growth and poverty reduction all depend. Dhaka reflects the challenges and opportunities for balancing these dynamic and complex trade-offs which goals can be achieved through effective policy interventions. There is a serious problem of water pollution in central Dhaka, in the Turag-Tongi-Balu River system in Bangladesh with the river system being one of the most polluted in the world at the moment. A baseline survey of water chemistry and total coliforms has been undertaken and shows dissolved oxygen close to zero in the dry season, high organic loading together with extreme levels of Ammonium-N and total coliform in the water. Models have been applied to assess hydrochemical processes in the river and evaluate alternative strategies for policy and the management of the pollution issues. In particular models of flow, Nitrate-N, Ammonium-N and indicator bacteria (total coliforms) are applied to simulate water quality in the river system. Various scenarios are explored to clean up the river system, including flow augmentation and improved effluent treatment. The model results indicate that improved effluent treatment is likely to have a more significant impact on reducing Ammonium-N and total coliforms than flow augmentation, but a combined strategy would greatly reduce the pollution problems in the Turag-Tongi-Balu River System. Copyright © 2018. Published by Elsevier B.V.
Climate relationships to fecal bacterial densities in Maryland shellfish harvest waters.
Leight, A K; Hood, R; Wood, R; Brohawn, K
2016-02-01
Coastal states of the United States (US) routinely monitor shellfish harvest waters for types of bacteria that indicate the potential presence of fecal pollution. The densities of these indicator bacteria in natural waters may be related to climate in several ways, including through runoff from precipitation and survival related to water temperatures. The relationship between interannual precipitation and air temperature patterns and the densities of fecal indicator bacteria in shellfish harvest waters in Maryland's portion of the Chesapeake Bay was quantified using 34 years of data (1979-2013). Annual and seasonal precipitation totals had a strong positive relationship with average fecal coliform levels (R(2) = 0.69) and the proportion of samples with bacterial densities above the FDA regulatory criteria (R(2) = 0.77). Fecal coliform levels were also significantly and negatively related to average annual air temperature (R(2) = -0.43) and the average air temperature of the warmest month (R(2) = -0.57), while average seasonal air temperature was only significantly related to fecal coliform levels in the summer. River and regional fecal coliform levels displayed a wide range of relationships with precipitation and air temperature patterns, with stronger relationships in rural areas and mainstem Bay stations. Fecal coliform levels tended to be higher in years when the bulk of precipitation occurred throughout the summer and/or fall (August to September). Fecal coliform levels often peaked in late fall and winter, with precipitation peaking in summer and early fall. Continental-scale sea level pressure (SLP) analysis revealed an association between atmospheric patterns that influence both extratropical and tropical storm tracks and very high fecal coliform years, while regional precipitation was found to be significantly correlated with the Atlantic Multidecadal Oscillation and the Pacific North American Pattern. These findings indicate that management of shellfish harvest waters should account for changes in climate conditions and that SLP patterns may be particularly important for predicting years with extremely high levels of fecal coliforms. Published by Elsevier Ltd.
Effect of turbidity on chlorination efficiency and bacterial persistence in drinking water.
LeChevallier, M W; Evans, T M; Seidler, R J
1981-01-01
To define interrelationships between elevated turbidities and the efficiency of chlorination in drinking water, experiments were performed to measure bacterial survival, chlorine demand, and interference with microbiological determinations. Experiments were conducted on the surface water supplies for communities which practice chlorination as the only treatment. Therefore, the conclusions of this study apply only to such systems. Results indicated that disinfection efficiency (log10 of the decrease in coliform numbers) was negatively correlated with turbidity and was influenced by season, chlorine demand of the samples, and the initial coliform level. Total organic carbon was found to be associated with turbidity and was shown to interfere with maintenance of a free chlorine residual by creating a chlorine demand. Interference with coliform detection in turbid waters could be demonstrated by the recovery of typical coliforms from apparently negative filters. The incidence of coliform masking in the membrane filter technique was found to increase as the turbidity of the chlorinated samples increased. the magnitude of coliform masking in the membrane filter technique increased from less than 1 coliform per 100 ml in water samples of less than 5 nephelometric turbidity units to greater than 1 coliform per 100 ml in water samples of greater than 5 nephelometric turbidity units. Statistical models were developed to predict the impact of turbidity on drinking water quality. The results justify maximum contaminant levels for turbidity in water entering a distribution system as stated in the National Primary Drinking Water Regulations of the Safe Drinking Water Act. Images PMID:7259162
Total Coliform Rule (TCR) Federal Register Notice
This document provides the FR notice to 40 CFR Parts 141 and 142 Drinking Water: National Primary Drinking Water Regulations; Total Coliforms (Including Fecal Coliforms and E. Coli); Final Rule (26 pp, 5 M).
Pathogen removal from domestic and swine wastewater by experimental constructed wetlands.
Giácoman-Vallejos, G; Ponce-Caballero, C; Champagne, P
2015-01-01
This study examined the performance of subsurface flow horizontal wetlands in total coliforms, faecal coliforms, enterococci and Salmonella removal from swine and domestic wastewaters. The effects of organic loading rate, contact time (CT) and the presence of aquatic macrophytes, Typha dominguensis and Typha latifolia, on treatment performance were evaluated. In general, chemical oxygen demand (COD) and total suspended solids (TSS) were reduced by 66 and 72% after 24 h and 75 and 84% after 48 h in domestic wastewaters, and 73 and 71% after 24 h and 72 and 78% after 48 h in swine wastewater. Total coliform and faecal coliform reductions of 70-83% and 65-78% were observed in the vegetated systems after 24 h of CT, while after 48 h, total coliform and faecal coliform reductions of 80-82% and 86-91% were noted.
[Banana peel: a possible source of infection in the treatment of nipple fissures].
Novak, Franz Reis; de Almeida, João Aprígio Guerra; de Souza e Silva, Rosana
2003-01-01
To study the microbiology of banana peel being sold in the city of Rio de Janeiro, in an attempt to determine the possibility that the peel may represent a source of infection for women who use it to treat nipple fissures. The following microorganisms were studied in 20 banana peel samples: mesophiles, total coliforms, fecal coliforms, Pseudomonas aeruginosa, lipolytic and proteolytic microorganisms, molds and yeasts, lactic bacteria, and coagulase-positive staphylococcus. The microbiological analyses revealed the occurrence of several typical groups of microorganisms, with the following distribution of positive results being detected in banana peel samples: mesophiles, 100%; total coliforms, 20%; coagulase-positive staphylococcus, 25%; molds and yeasts, 30%; proteolytic microorganisms, 70%; lipolytic microorganisms, 30%, and lactic bacteria, 95%. Fecal coliforms and Pseudomonas aeruginosa were not isolated. The results show the presence of potentially pathogenic microorganisms in levels which could compromise the microbiological quality of the banana peel. Its use for the treatment of nipple fissures can initiate an infectious process.
Factors Associated with the Presence of Coliforms in the Feed and Water of Feedlot Cattle
Sanderson, Michael W.; Sargeant, Jan M.; Renter, David G.; Griffin, D. Dee; Smith, Robert A.
2005-01-01
The objective of this study was to investigate coliform counts in feedlot cattle water and feed rations and their associations with management, climate, fecal material, and water Escherichia coli O157 using a cross-sectional study design. Coliform counts were performed on feed samples from 671 pens on 70 feedlots and on water samples from 702 pens on 72 feedlots in four U.S. states collected between May and August 2001. Management and climate factors were obtained by survey and observation. Month of sampling (higher in May and June), presence of corn silage in the ration (negative association), temperature of the feed 1 in. (ca. 2.5 cm) below the surface at the time of sampling (negative association), and wind velocity at the time of sampling (positive association) were significantly associated with log10 coliform levels in feed. Month of sampling (lower in May versus June July and August), water pH (negative association), and water total solids (positive association) were significantly associated with log10 water coliform levels. Coliform counts in feed and water were not associated with prevalence of E. coli O157 in cattle feces or water. Management risk factors must be interpreted with caution but the results reported here do not support the use of coliform counts as a marker for E. coli O157 contamination of feed or water. PMID:16204517
Enteropathogenic Bacteria Contamination of Unchlorinated Drinking Water in Korea, 2010
Lee, Si Won; Lee, Do Kyung; An, Hyang Mi; Cha, Min Kyeong; Kim, Kyung Jae
2011-01-01
Objectives The purpose of this study was to assess the microbiological quality of unchlorinated drinking water in Korea, 2010. One hundred and eighty unchlorinated drinking water samples were collected from various sites in Seoul and Gyeonggi province. Methods To investigate bacterial presence, the pour plate method was used with cultures grown on selective media for total bacteria, total coliforms, and Staphylococcus spp., respectively. Results In the 180 total bacteria investigation, 72 samples from Seoul and 33 samples from Gyeonggi province were of an unacceptable quality (>102 CFU/mL). Of all the samples tested, total coliforms were detected in 28 samples (15.6%) and Staphylococcus spp. in 12 samples (6.7%). Most of the coliform isolates exhibited high-level resistance to cefazolin (88.2%), cefonicid (64.7%) and ceftazidime (20.6%). In addition, Staphylococcus spp. isolates exhibited high-level resistance to mupirocin (42%). Species of Pseudomonas, Acinetobacter, Cupriavidus, Hafnia, Rahnella, Serratia, and Yersinia were isolated from the water samples. Conclusions The results of this study suggest that consumption of unchlorinated drinking water could represent a notable risk to the health of consumers. As such, there is need for continuous monitoring of these water sources and to establish standards. PMID:22216417
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-16
... Currently Approved Total Coliform Analytical Methods AGENCY: Environmental Protection Agency (EPA). ACTION... of currently approved Total Coliform Rule (TCR) analytical methods. At these meetings, stakeholders will be given an opportunity to discuss potential elements of a method re-evaluation study, such as...
75 FR 42440 - Total Coliform Rule Revisions-Notice of Public Information Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-21
... will be discussed include the cost and benefit information of the proposed rule and the planned... ENVIRONMENTAL PROTECTION AGENCY [FRL-9177-6] Total Coliform Rule Revisions--Notice of Public... Protection Agency (EPA) is hosting public information meetings on the proposed Revised Total Coliform Rule...
Kelly, Brian P.; Rydlund, Jr., Paul H.
2006-01-01
Riverbank filtration substantially improves the source-water quality of the Independence, Missouri well field. Coliform bacteria, Cryptosporidium, Giardia, viruses and selected constituents were analyzed in water samples from the Missouri River, two vertical wells, and a collector well. Total coliform bacteria, Cryptosporidium, Giardia, and total culturable viruses were detected in the Missouri River, but were undetected in samples from wells. Using minimum reporting levels for non-detections in well samples, minimum log removals were 4.57 for total coliform bacteria, 1.67 for Cryptosporidium, 1.67 for Giardia, and 1.15 for total culturable virus. Ground-water flow rates between the Missouri River and wells were calculated from water temperature profiles and ranged between 1.2 and 6.7 feet per day. Log removals based on sample pairs separated by the traveltime between the Missouri River and wells were infinite for total coliform bacteria (minimum detection level equal to zero), between 0.8 and 3.5 for turbidity, between 1.5 and 2.1 for Giardia, and between 0.4 and 2.6 for total culturable viruses. Cryptosporidium was detected once in the Missouri River but no corresponding well samples were available. No clear relation was evident between changes in water quality in the Missouri River and in wells for almost all constituents. Results of analyses for organic wastewater compounds and the distribution of dissolved oxygen, specific conductance, and temperature in the Missouri River indicate water quality on the south side of the river was moderately influenced by the south bank inflows to the river upstream from the Independence well field.
40 CFR 141.4 - Variances and exemptions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... coliform MCL of § 141.63(a) for systems that demonstrate to the State that the violation of the total coliform MCL is due to a persistent growth of total coliforms in the distribution system rather than fecal...
40 CFR 141.4 - Variances and exemptions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... coliform MCL of § 141.63(a) for systems that demonstrate to the State that the violation of the total coliform MCL is due to a persistent growth of total coliforms in the distribution system rather than fecal...
Drinking water regulations under the Final Coliform Rule require that total coliform-positive drinking water samples be examined for the presence of Escherichia coli or fecal coliforms. The current U.S. Environmental Protection Agency-approved membrane filter (MF) method for E. c...
Berrang, M E; Dickens, J A; Musgrove, M T
2000-11-01
Scalding has been found to lower the levels of Campylobacter on broiler carcasses. However, the numbers recovered from whole-carcass rinse samples increase following defeathering. This study was undertaken to examine the effect of a second scald applied after defeathering on microbial levels recovered from carcass rinses. Four treatments were evaluated: 1) immersion at 60 C for 28 s 30 min after defeathering, 2) immersion at 60 C for 28 s immediately after defeathering, 3) spray at 73 C for 20 s 30 min after defeathering, and 4) spray at 71 C for 20 s immediately after defeathering. As reported earlier, a significant increase in Campylobacter counts per mL whole carcass rinse was noted after carcasses were defeathered. However, when applied 30 min after defeathering, neither the immersion nor the spray second scald treatments lowered the Campylobacter counts. Likewise, neither treatment had any affect on Escherichia coli or coliform bacteria counts, even though total counts were slightly reduced by the treatments. When the second scald treatment immediately followed defeathering, the same trends were observed. Campylobacter counts after the second scald remained at the postpick levels, as did counts for E. coli and coliform bacteria, but total plate counts were slightly reduced. Overall, it would appear that a postscald treatment gentle enough not to alter the carcass appearance or meat quality would not effectively lower Campylobacter, E. coli, or coliform bacteria counts.
40 CFR 412.2 - General definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
....23. (c) Fecal coliform means the bacterial count (Parameter 1) at 40 CFR 136.3 in Table 1A, which... Table 1A at 40 CFR 136.3 are defined as follows: (1) Fecal coliform means fecal coliform bacteria. (2) Total coliform means all coliform bacteria. ...
Rubio-Arias, Hector; Rey, Nora I; Quintana, Rey M; Nevarez, G Virginia; Palacios, Oskar
2011-06-01
Lago de Colina (Colina Lake) is located about 180 km south of the city of Chihuahua (Mexico), and during the Semana Santa (Holy Week) vacation period its recreational use is high. The objective of this study was to quantify coliform and heavy metal levels in this water body before and after the Holy Week vacation period in 2010. Twenty sampling points were randomly selected and two water samples were collected at each point near the surface (0.30 m) and at 1 m depth. After the Holy Week vacation the same twenty points were sampled at the same depths. Therefore, a total 80 water samples were analyzed for fecal and total coliforms and levels of the following metals: Al, As, B, Ca, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, Se, Si and Zn. It was hypothesized that domestic tourism contaminated this water body, and as a consequence, could have a negative impact on visitor health. An analysis of variance (ANOVA) study was performed for each element and its interactions considering a factorial design where factor A was sample date and factor B was sample depth. Fecal coliforms were only detected at eight sampling points in the first week, but after Holy Week, both fecal and total coliforms were detected at most sampling points. The concentrations of Al, B, Na, Ni and Se were only statistically different for factor A. The levels of Cr, Cu, K and Mg was different for both date and depth, but the dual factor interaction was not significant. The amount of Ca and Zn was statistically different due to date, depth and their interaction. No significant differences were found for any factor or the interaction for the elements As, Fe and Mn. Because of the consistent results, it is concluded that local tourism is contaminating the recreational area of Colina Lake, Chihuahua, Mexico.
Rubio-Arias, Hector; Rey, Nora I.; Quintana, Rey M.; Nevarez, G. Virginia; Palacios, Oskar
2011-01-01
Lago de Colina (Colina Lake) is located about 180 km south of the city of Chihuahua (Mexico), and during the Semana Santa (Holy Week) vacation period its recreational use is high. The objective of this study was to quantify coliform and heavy metal levels in this water body before and after the Holy Week vacation period in 2010. Twenty sampling points were randomly selected and two water samples were collected at each point near the surface (0.30 m) and at 1 m depth. After the Holy Week vacation the same twenty points were sampled at the same depths. Therefore, a total 80 water samples were analyzed for fecal and total coliforms and levels of the following metals: Al, As, B, Ca, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, Se, Si and Zn. It was hypothesized that domestic tourism contaminated this water body, and as a consequence, could have a negative impact on visitor health. An analysis of variance (ANOVA) study was performed for each element and its interactions considering a factorial design where factor A was sample date and factor B was sample depth. Fecal coliforms were only detected at eight sampling points in the first week, but after Holy Week, both fecal and total coliforms were detected at most sampling points. The concentrations of Al, B, Na, Ni and Se were only statistically different for factor A. The levels of Cr, Cu, K and Mg was different for both date and depth, but the dual factor interaction was not significant. The amount of Ca and Zn was statistically different due to date, depth and their interaction. No significant differences were found for any factor or the interaction for the elements As, Fe and Mn. Because of the consistent results, it is concluded that local tourism is contaminating the recreational area of Colina Lake, Chihuahua, Mexico. PMID:21776236
Martin, Anthony Richard; Coombes, Peter John; Harrison, Tracey Lee; Hugh Dunstan, R
2010-01-01
Microbial properties of harvested rainwater were assessed at two study sites at Newcastle on the east coast of Australia. The investigation monitored daily counts of heterotrophic bacteria (HPC), total coliforms and E. coli during a mid-winter month (July). Immediately after a major rainfall event, increases in bacterial loads were observed at both sites, followed by gradual reductions in numbers to prior baseline levels within 7 days. Baseline HPC levels ranged from 500-1000 cfu/mL for the sites evaluated, and the loads following rain peaked at 3590-6690 cfu/mL. Baseline levels of total coliforms ranged from 0-100 cfu/100 mL and peaked at 480-1200 cfu/100 mL following rain. At Site 1, there was no evidence of E. coli loading associated with the rain events assessed, and Site 2 had no detectable E.coli colonies at baseline, with a peak load of 17 cfu/100 mL following rain which again diminished to baseline levels. It was concluded that rainfall events contributed to the bacterial load in rainwater storage systems, but processes within the rainwater storage ensured these incoming loads were not sustained.
Microbiological contamination in water filtration plants in Islamabad.
Hisam, Aliya; Ur Rahman, Mahmood; Kadir, Ehsan; Tariq, Naseer Alam; Masood, Sumaira
2014-05-01
To determine the frequency of microbiological contamination of water in different water filtration plants in Islamabad. Descriptive cross-sectional study. Water Filtration Plants (WFP) in different sectors of Islamabad, from April to September 2012. Water samples were collected in sterilized bottles according to the standard water sampling protocol from site and transported to Pakistan Council for Research in Water Resources (PCRWR) for analysis. Microbiological quality of water was determined in terms of total coliforms (< 2.0 MPN/100 ml) and Escherichia coli (< 2.0 MPN/100 ml). Microbiological contaminated water was defined the sample which had more than 2.0 MPN per 100 ml of either total coliforms or Escherichia (E.) coli. Thirty two WFP were analyzed for microbiological contamination. E. coli was present in 8 (25.0%) water samples, while 24 (75.0%) water samples were free from it. Total coliforms were present in 13 (40.6%) of the samples of WFP, while 19 (59.3%) samples were free from total coliform. Faecal coliforms were present in 8 (25.0%) and absent in 24 (75.0%) samples. Both E. coli and total coliform were present in 8 (25.0%) samples. Nine (59.3) WFP were free from E. coli, total coliform and faecal coliform. Statistically, no significant association was found (p > 0.05) between microbiological contamination and the sectors. Less than half of the water samples of the WFP were contaminated while certain sectors showed more frequent contamination than others.
Wastewater disinfection alternatives: chlorine, ozone, peracetic acid, and UV light.
Mezzanotte, V; Antonelli, M; Citterio, S; Nurizzo, C
2007-11-01
Disinfection tests were carried out at pilot scale to compare the disinfection efficiency of ozone, sodium hypochlorite (NaOCl), peracetic acid (PAA), and UV irradiation. Total coliforms, fecal coliforms, and Escherichia coli were monitored as reference microorganisms. Total heterotrophic bacteria (THB) were also enumerated by cytometry. At similar doses, NaOCl was more effective than PAA, and its action was less affected by contact time. The results obtained by ozonation were comparable for total coliforms, fecal coliforms, and E. coli. On the contrary, some differences among the three indicators were observed for NaOCl, PAA, and UV. Differences increased with increasing values of the disinfectant concentration times contact time (C x t) and were probably the result of different initial counts, as total coliforms include fecal coliforms, which include E. coli. The UV irradiation lead to complete E. coli removals, even at low doses (10 to 20 mJ/cm2). Total heterotrophic bacteria appeared to be too wide a group to be a good disinfection indicator; no correlation was found among THB inactivation, dose, and contact time.
Yassin, Maged Mohammed; Amr, Salem S Abu; Al-Najar, Husam M
2006-12-01
To assess the contamination level of total and faecal coliforms in water wells and distribution networks, and their association with human health in Gaza Governorate, Gaza Strip. Data were obtained from the Palestinian Ministry of Health on contamination of total and faecal coliforms in water wells and distribution networks, and on the incidence of water-related diseases in Gaza Governorate. An interview questionnaire was conducted with 150 residents of Gaza. The contamination level of total and faecal coliforms exceeded that of the World Health Organization (WHO) limit for water wells and networks. However, the contamination percentages in networks were higher than that in wells. Giardiasis was strongly correlated with faecal coliform contamination in water networks (r=0.7) compared with diarrhoeal diseases and hepatitis A (r=0.3 and 0.1, respectively). Diarrhoeal diseases were the highest self-reported diseases among interviewees in Gaza city. Such diseases were more prevalent among people using municipal water than people using desalinated water and water filtered at home for drinking (OR=1.6). Intermittent water supply and sewage flooding seemed to contribute largely to self-reported diseases. People in Gaza Strip have good knowledge on drinking water contamination, and this is reflected in good practice. Water quality has deteriorated in Gaza Strip. This may contribute to the prevalence of water-related diseases. Self-reported diseases among interviewees in Gaza City were associated with source of drinking water, intermittent water supply, sewage flooding and age of water, and wastewater networks.
Bacterial Pollution Indicators in the Intestinal Tract of Freshwater Fish
Geldreich, Edwin E.; Clarke, Norman A.
1966-01-01
A study was made of the occurrence, distribution, and persistence of coliforms, fecal coliforms, and fecal streptococci in the intestinal tract of freshwater fish. A total of 132 fish representing 14 different species were used in various phases of these experiments. Examination of the intestinal contents of 78 fish from moderately polluted sections of the Little Miami River indicated that fecal coliform densities were lowest in bluegills (less than 20 per gram) and highest in catfish (1,090,000 per gram). Levels of fecal streptococci for these two species were 220 and 240,000 per gram, respectively. The occurrence of fecal coliforms in fish caught in this stream reflected the warm-blooded-animal-pollution level of the water. All fish used in this phase of the study were caught during July, August, and September when the water temperatures were between 13 and 18 C. The fate of fecal coliforms and Streptococcus faecalis in the fish intestine indicated that these organisms can probably survive and multiply when fish and water temperatures are 20 C or higher, but only when the organisms are retained in the gut for periods beyond 24 hr. Based on the biochemical reactions for 3,877 coliform strains isolated from 132 freshwater fish of 14 different species, 91.4% of all strains were composed of five IMViC types. In a similar study of the biochemical reactions of 850 streptococci isolated from the intestinal tract of 55 freshwater fish, the predominant strains included S. faecalis and various closely associated biotypes. No consistently recurring pattern for either coliforms or streptococci could be developed to identify species of fish investigated. The composition of the intestinal flora is, however, related in varying degree to the level of contamination of water and food in the environment. Images Fig. 1 Fig. 2 PMID:6008184
Aulenbach, Brent T.
2010-01-01
Bacteria holding-time experiments of up to 62 h were performed on five surface-water samples from four urban stream sites in the vicinity of Atlanta, GA, USA that had relatively high densities of coliform bacteria (Escherichia coli densities were all well above the US Environmental Protection Agency criterion of 126 colonies (100 ml) − 1 for recreational waters). Holding-time experiments were done for fecal coliform using the membrane filtration modified fecal coliform (mFC) agar method and for total coliform and E. coli using the Colilert®-18 Quanti-Tray® method. The precisions of these analytical methods were quantified. Precisions determined for fecal coliform indicated that the upper bound of the ideal range of counts could reasonably be extended upward and would improve precision. For the Colilert®-18 method, analytical precisions were similar to the theoretical precisions for this method. Fecal and total coliform densities did not change significantly with holding times up to about 27 h. Limited information indicated that fecal coliform densities might be stable for holding times of up to 62 h, whereas total coliform densities might not be stable for holding times greater than about 27 h. E. coli densities were stable for holding times of up to 18 h—a shorter period than indicated from a previous studies. These results should be applicable to non-regulatory monitoring sampling designs for similar urban surface-water sample types.
Gil, Ana I; Lanata, Claudio F; Hartinger, Stella M; Mäusezahl, Daniel; Padilla, Beatriz; Ochoa, Theresa J; Lozada, Michelle; Pineda, Ines; Verastegui, Hector
2014-01-01
The study described in this article evaluated sources of contamination of children's food and drinking water in rural households in the highlands of Peru. Samples from children's meals, drinking water, kitchen utensils, and caregivers' and children's hands were analyzed for total coliforms and E. coli counts using Petrifilm EC. Thermotolerant coliforms in water were measured using DelAgua test kits while diarrheagenic E. coli was identified using polymerase chain reaction methods (PCR). Thermotolerant coliforms were found in 48% of all water samples. E. coli was found on 23% of hands, 16% of utensils, and 4% of meals. Kitchen cloths were the item most frequently contaminated with total coliforms (89%) and E. coli (42%). Diarrheagenic E. coli was found in 33% of drinking water, 27% of meals, and on 23% of kitchen utensils. These findings indicate a need to develop hygiene interventions that focus on specific kitchen utensils and hand washing practices, to reduce the contamination of food, water, and the kitchen environment in these rural settings.
Bacteriological and Physical Quality of Locally Packaged Drinking Water in Kampala, Uganda
Halage, Abdullah Ali; Ssemugabo, Charles; Ssemwanga, David K.; Musoke, David; Mugambe, Richard K.; Guwatudde, David; Ssempebwa, John C.
2015-01-01
Objective. To assess the bacteriological and physical quality of locally packaged drinking water sold for public consumption. Methods. This was cross-sectional study where a total of 60 samples of bottled water from 10 brands and 30 samples of sachet water from 15 brands purchased randomly were analyzed for bacteriological contamination (total coliform and faecal coliform per 100 mL) using membrane filtrate method and reported in terms of cfu/100 mL. Results. Both bottled water and sachet water were not contaminated with faecal coliform. Majority (70%, 21/30) of the sachet water analyzed exceeded acceptable limits of 0 total coliforms per 100 mL set by WHO and the national drinking water standards. The physical quality (turbidity and pH) of all the packaged water brands analyzed was within the acceptable limits. There was statistically significant difference between the median count of total coliform in both sachet water and bottled water brands (U(24) = 37.0, p = 0.027). Conclusion. Both bottled water and sachet water were not contaminated with faecal coliforms; majority of sachet water was contaminated with total coliform above acceptable limits. Government and other stakeholders should consider intensifying surveillance activities and enforcing strict hygienic measures in this rapidly expanding industry to improve packaged water quality. PMID:26508915
Bacteriological and physical quality of locally packaged drinking water in Kampala, Uganda.
Halage, Abdullah Ali; Ssemugabo, Charles; Ssemwanga, David K; Musoke, David; Mugambe, Richard K; Guwatudde, David; Ssempebwa, John C
2015-01-01
To assess the bacteriological and physical quality of locally packaged drinking water sold for public consumption. This was cross-sectional study where a total of 60 samples of bottled water from 10 brands and 30 samples of sachet water from 15 brands purchased randomly were analyzed for bacteriological contamination (total coliform and faecal coliform per 100 mL) using membrane filtrate method and reported in terms of cfu/100 mL. Both bottled water and sachet water were not contaminated with faecal coliform. Majority (70%, 21/30) of the sachet water analyzed exceeded acceptable limits of 0 total coliforms per 100 mL set by WHO and the national drinking water standards. The physical quality (turbidity and pH) of all the packaged water brands analyzed was within the acceptable limits. There was statistically significant difference between the median count of total coliform in both sachet water and bottled water brands (U(24) = 37.0, p = 0.027). Both bottled water and sachet water were not contaminated with faecal coliforms; majority of sachet water was contaminated with total coliform above acceptable limits. Government and other stakeholders should consider intensifying surveillance activities and enforcing strict hygienic measures in this rapidly expanding industry to improve packaged water quality.
Gas Chromatographic Presumptive Test for Coliform Bacteria in Water
Newman, Judith S.; O'Brien, R. T.
1975-01-01
A gas chromatographic procedure which shows promise as a presumptive test for coliform bacteria in water is described. Total coliform bacteria concentrations were determined from the incubation times at 37 C required for ethanol to be produced. Fecal coliform densities were determined in a similar manner at 44.5 C. The culture medium was filter sterilized M-9 salts supplemented with 1% lactose, 0.1% Casamino Acids, and 0.1% yeast extract. Best results were obtained when the initial total coliform concentrations were 5 per ml or higher and when fecal coliform concentrations were 50 per ml or higher. Minimum detection times at these concentrations were 9 and 12 h, respectively. PMID:1103731
Christensen, Sarah C. B.; Arvin, Erik; Nissen, Erling; Albrechtsen, Hans-Jørgen
2013-01-01
Individuals of the water louse, Asellus aquaticus, enter drinking water distribution systems in temperate parts of the world, where they establish breeding populations. We analysed populations of surface water A. aquaticus from two ponds for associated faecal indicator bacteria and assessed the risk of A. aquaticus transporting bacteria into distribution systems. Concentrations of up to two E. coli and five total coliforms·mL−1 were measured in the water and 200 E. coli and >240 total coliforms·mL−1 in the sediments of the investigated ponds. Concentrations of A. aquaticus associated bacteria never exceeded three E. coli and six total coliforms·A. aquaticus−1. During exposure to high concentrations of coliforms, concentrations reached 350 coliforms·A. aquaticus−1. A. aquaticus associated E. coli were only detected as long as E. coli were present in the water and sediment. The calculated probability of exceeding drinking water guideline values in non-disinfected systems by intrusion of A. aquaticus was low. Only in scenarios with narrow pipes and low flows, did total coliforms exceed guideline values, implying that the probability of detection by routine monitoring is also low. The study expands the knowledge base for evaluating incidents with presence of coliform indicators in drinking water by showing that intruding A. aquaticus were not important carriers of E. coli or other coliform bacteria even when emerging from faecally contaminated waters. PMID:23455399
Christensen, Sarah C B; Arvin, Erik; Nissen, Erling; Albrechtsen, Hans-Jørgen
2013-03-01
Individuals of the water louse, Asellus aquaticus, enter drinking water distribution systems in temperate parts of the world, where they establish breeding populations. We analysed populations of surface water A. aquaticus from two ponds for associated faecal indicator bacteria and assessed the risk of A. aquaticus transporting bacteria into distribution systems. Concentrations of up to two E. coli and five total coliforms·mL-1 were measured in the water and 200 E. coli and >240 total coliforms·mL-1 in the sediments of the investigated ponds. Concentrations of A. aquaticus associated bacteria never exceeded three E. coli and six total coliforms·A. aquaticus-1. During exposure to high concentrations of coliforms, concentrations reached 350 coliforms·A. aquaticus-1. A. aquaticus associated E. coli were only detected as long as E. coli were present in the water and sediment. The calculated probability of exceeding drinking water guideline values in non-disinfected systems by intrusion of A. aquaticus was low. Only in scenarios with narrow pipes and low flows, did total coliforms exceed guideline values, implying that the probability of detection by routine monitoring is also low. The study expands the knowledge base for evaluating incidents with presence of coliform indicators in drinking water by showing that intruding A. aquaticus were not important carriers of E. coli or other coliform bacteria even when emerging from faecally contaminated waters.
ESCHERICHIA COLI AND TOTAL COLIFORMS IN WATER AND SEDIMENTS AT LAKE MARINAS
Escherichia coli, a fecal coliform, and total coliforms were monitored between September 1999 to October 2001 in five marinas on Lake Texoma, located on the Oklahoma and Texas border. General trend was that densities of E. coli were lower in the summer season due to the lower ...
Seasonal Microbial Conditions of Locally Made Yoghurt (Shalom) Marketed in Some Regions of Cameroon
Moh, Lamye Glory; Keilah, Lunga Paul; Etienne, Pamo Tedonkeng
2017-01-01
The microbial conditions of locally made yoghurt (shalom) marketed in three areas of Cameroon were evaluated during the dry and rainy seasons alongside three commercial brands. A total of ninety-six samples were collected and the microbial conditions were based on total aerobic bacteria (TEB), coliforms, yeasts, and moulds counts as well as the identification of coliforms and yeasts using identification kits. Generally, there was a significant increase (p ≤ 0.05) in total aerobic and coliform counts (especially samples from Bamenda), but a decrease in yeast and mould counts of the same samples during the rainy season when compared to those obtained during the dry season. These counts were mostly greater than the recommended standards. Twenty-one Enterobacteriaceae species belonging to 15 genera were identified from 72 bacterial isolates previously considered as all coliforms. Pantoea sp. (27.77%) was highly represented, found in 41% (dry season) and 50% (rainy season) of samples. In addition, sixteen yeast species belonging to 8 genera were equally identified from 55 yeast isolates and Candida sp. (76.36%) was the most represented. This result suggests that unhygienic practices during production, ignorance, warmer weather, duration of selling, and inadequate refrigeration are the principal causes of higher levels of contamination and unsafe yoghurts. PMID:29423400
Effects of a tropical cyclone on the drinking-water quality of a remote Pacific island.
Mosley, Luke M; Sharp, Donald S; Singh, Sarabjeet
2004-12-01
The effect of a cyclone (Ami, January 2003) on drinking-water quality on the island of Vanua Levu, Fiji was investigated. Following the cyclone nearly three-quarters of the samples analysed did not conform to World Health Organisation (WHO) guideline values for safe drinking-water in terms of chlorine residual, total and faecal coliforms, and turbidity. Turbidity and total coliform levels significantly increased (up 56 and 62 per cent, respectively) from pre-cyclone levels, which was likely due to the large amounts of silt and debris entering water-supply sources during the cyclone. The utility found it difficult to maintain a reliable supply of treated water in the aftermath of the disaster. Communities were unaware they were drinking water that had not been adequately treated. Circumstances permitted this cyclone to be used as a case study to assess whether a simple paper-strip water-quality test (the hydrogen sulphide, H(2)S) kit could be distributed and used for community-based monitoring following such a disaster event to better protect public health. The H(2)S test results correlated well with faecal and total coliform results as found in previous studies. A small percentage of samples (about 10 per cent) tested positive for faecal and total coliforms but did not test positive in the H(2)S test. It was concluded that the H(2)S test would be well suited to wider use, especially in the absence of water-quality monitoring capabilities for outer island groups as it is inexpensive and easy to use, thus enabling communities and community health workers with minimal training to test their own water supplies without outside assistance. The importance of public education before and after natural disasters is also discussed.
Code of Federal Regulations, 2013 CFR
2013-07-01
... REGULATIONS Revised Total Coliform Rule § 141.857 Routine monitoring requirements for public water systems... systems serving more than 1,000 persons. (2) Following any total coliform-positive sample taken under the... calendar month has been completed, systems must determine whether any coliform treatment technique triggers...
Quality assessment of commercially supplied drinking jar water in Chittagong City, Bangladesh
NASA Astrophysics Data System (ADS)
Mina, Sohana Akter; Marzan, Lolo Wal; Sultana, Tasrin; Akter, Yasmin
2018-03-01
Chittagong is the second most populated city in Bangladesh where drinking water is supplied using small jar. Water quality is an important concern for the consumers and, therefore, the present study was done by collecting 38 drinking jar water samples from Chittagong City, Bangladesh to determine the microbial contamination and physiochemical properties. Molecular study was done by the PCR amplification of 16SrDNA, LacZ and uidA gene for the identification of bacteria, coliform and fecal coliform. TVC, MPN and different biochemical test were done for enumeration and identification. TDS, pH, and metals (Fe, As, Pb and Cr) concentration were also measured. No heavy metal (As, Pb and Cr) was found in any of the water samples but Fe was detected in low concentrations (0.02-0.05 mg/l). TDS and pH level were normal in all samples. But microbial contaminations were (60.53 and 50%) recorded in molecular and biochemical test, respectively. The range of total bacterial count was (1.5 × 102-1.6 × 104) cfu/ml. The total coliform count (TCCm) was recorded (14-40) in 100 ml of water samples. The presence of total coliform and fecal coliform was 26.32 and 18.42%, respectively, in PCR analysis but in biochemical test those were 18.42 and 15.78%, respectively. A total of 11 bacterial species: Enterobacter aerogenes, Escherrichia coli, Aeromonas, Bacillus sp., Cardiobacterium, Corynebacterium, Clostridium, Klebsiella sp., Lactobacillus, Micrococcus sp., Pseudomonas sp. were found. This study indicates that some of the drinking jar water samples were of poor quality which may increase the risk of water-borne disease. Hence, the producer of drinking jar water has to implement necessary quality control steps.
Hervert, C J; Alles, A S; Martin, N H; Boor, K J; Wiedmann, M
2016-09-01
It is estimated that 19% of the total food loss from retail, food service, and households comes from dairy products. A portion of this loss may be attributed to premature spoilage of products due to lapses in sanitation and postpasteurization contamination at the processing level. Bacterial groups including coliforms, Enterobacteriaceae (EB), and total gram-negative organisms represent indicators of poor sanitation or postpasteurization contamination in dairy products worldwide. Although Petrifilms (3M, St. Paul, MN) and traditional selective media are commonly used for the testing of these indicator organism groups throughout the US dairy industry, new rapid methods are also being developed. This project was designed to evaluate the ability of different methods to detect coliforms, EB, and other gram-negative organisms isolated from various dairy products and dairy processing environments. Using the Food Microbe Tracker database, a collection of 211 coliform, EB, and gram-negative bacterial isolates representing 25 genera associated with dairy products was assembled for this study. We tested the selected isolates in pure culture (at levels of approximately 15 to 300 cells/test) to evaluate the ability of 3M Coliform Petrifilm to detect coliforms, 3M Enterobacteriaceae Petrifilm, violet red bile glucose agar, and an alternative flow cytometry-based method (bioMérieux D-Count, Marcy-l'Étoile, France) to detect EB, and crystal violet tetrazolium agar to detect total gram-negative organisms. Of the 211 gram-negative isolates tested, 82% (174/211) had characteristic growth on crystal violet tetrazolium agar. Within this set of 211 gram-negative organisms, 175 isolates representing 19 EB genera were screened for detection using EB selective/differential testing methods. We observed positive results for 96% (168/175), 90% (158/175), and 86% (151/175) of EB isolates when tested on EB Petrifilm, violet red bile glucose agar, and D-Count, respectively; optimization of the cut-off thresholds for the D-Count may further improve its sensitivity and specificity, but will require additional data and may vary in food matrices. Additionally, 74% (129/175) of the EB isolates tested positive as coliforms. The data obtained from this study identify differences in detection between 5 microbial hygiene indicator tests and highlight the benefits of EB and total gram-negative testing methods. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Moyo, N. A. G.
Groundwater from boreholes and shallow wells is a major source of drinking water in most rural areas of Zimbabwe. The quality of groundwater has been taken for granted and the status and the potential threats to groundwater quality have not been investigated on a large scale in Zimbabwe. A borehole and shallow well water quality survey was undertaken between January, 2009 and February, 2010 to determine the chemical and microbial aspects of drinking water in three catchment areas. Groundwater quality physico-chemical indicators used in this study were nitrates, chloride, water hardness, conductivity, alkalinity, total dissolved solids, iron, magnesium, manganese, potassium, calcium, fluoride, sulphates, sodium and pH. The microbiological indicators were total coliforms, faecal coliforms and heterotrophs. Principal component analysis (PCA) showed that most of the variation in ground water quality in all catchment areas is accounted for by Total Dissolved Solids (TDS), electrical conductivity (EC), sodium, bicarbonate and magnesium. The principal dissolved constituents in ground water are in the form of electrically charged ions. Nitrate is a significant problem as the World Health Organization recommended levels were exceeded in 36%, 37% and 22% of the boreholes in the Manyame, Mazowe and Gwayi catchment areas respectively. The nitrate levels were particularly high in commercial farming areas. Iron and manganese also exceeded the recommended levels. The probable source of high iron levels is the underlying geology of the area which is dominated by dolerites. Dolerites weather to give soils rich in iron and other mafic minerals. The high level of manganese is probably due to the lithology of the rock as well as mining activity in some areas. Water hardness is a problem in all catchment areas, particularly in the Gwayi catchment area where a value of 2550 mg/l was recorded in one borehole. The problems with hard water use are discussed. Chloride levels exceeded the recommended levels in a few areas under irrigation. Most of the chloride is probably from agricultural activity particularly the application of potassium chloride. Fluoride levels were particularly elevated in the Gwayi catchment area and this is because of the geology of the area. There was no evidence of microbial contamination in all the boreholes sampled as the total coliform, faecal coliforms, heterotrophs count was nil. However, severe microbial contamination was found in the wells especially those in clay areas.
Coliform Sources and Mechanisms for Regrowth in Household Drinking Water in Limpopo, South Africa.
Mellor, Jonathan E; Smith, James A; Samie, Amidou; Dillingham, Rebecca A
2013-09-01
Resource-limited communities throughout the developing world face significant environmental health problems related to the myriad of coliform sources within those communities. This study comprehensively investigated contamination sources and the biological and chemical mechanisms sustaining them in two adjacent communities in rural Limpopo, South Africa. An 8-month study was conducted of household ( n = 14) and source water quality, measurements of biofilm layers on the inside of household water storage containers and water transfer devices, and also hand-based coliforms and hand-washing effectiveness. A 7-day water container incubation experiment was also performed to determine the biological and chemical changes that occur in a household water storage container independent of human interference. Results indicate that household drinking water frequently becomes contaminated after collection but before consumption (197 versus 1,046 colony-forming units/100 mL; n = 266; p < 0.001). The most important contamination sources include biofilm layers on the inside of storage containers (1.85 ± 1.59 colony-forming units/cm 2 ; n = 44), hands (5,097 ± 2,125 colony-forming units/hand; n = 48), and coliform regrowth resulting from high assimilable organic carbon (AOC) levels during storage. A maximum specific growth rate, μ max , of 0.072 ± 0.003 h -1 was determined for total coliform bacteria on AOC, and a high correlation between AOC concentrations and the growth potential of total coliform bacteria was observed. These results support the implementation of point-of-use water treatment and other interventions aimed at maintaining the safe water chain and preventing biological regrowth.
Coliform Sources and Mechanisms for Regrowth in Household Drinking Water in Limpopo, South Africa
Mellor, Jonathan E.; Samie, Amidou; Dillingham, Rebecca A.
2014-01-01
Resource-limited communities throughout the developing world face significant environmental health problems related to the myriad of coliform sources within those communities. This study comprehensively investigated contamination sources and the biological and chemical mechanisms sustaining them in two adjacent communities in rural Limpopo, South Africa. An 8-month study was conducted of household (n = 14) and source water quality, measurements of biofilm layers on the inside of household water storage containers and water transfer devices, and also hand-based coliforms and hand-washing effectiveness. A 7-day water container incubation experiment was also performed to determine the biological and chemical changes that occur in a household water storage container independent of human interference. Results indicate that household drinking water frequently becomes contaminated after collection but before consumption (197 versus 1,046 colony-forming units/100 mL; n = 266; p < 0.001). The most important contamination sources include biofilm layers on the inside of storage containers (1.85 ± 1.59 colony-forming units/cm2; n = 44), hands (5,097 ± 2,125 colony-forming units/hand; n = 48), and coliform regrowth resulting from high assimilable organic carbon (AOC) levels during storage. A maximum specific growth rate, μmax, of 0.072 ± 0.003 h−1 was determined for total coliform bacteria on AOC, and a high correlation between AOC concentrations and the growth potential of total coliform bacteria was observed. These results support the implementation of point-of-use water treatment and other interventions aimed at maintaining the safe water chain and preventing biological regrowth. PMID:25190902
Molecular method for detection of total coliforms in drinking water samples.
Maheux, Andrée F; Boudreau, Dominique K; Bisson, Marc-Antoine; Dion-Dupont, Vanessa; Bouchard, Sébastien; Nkuranga, Martine; Bergeron, Michel G; Rodriguez, Manuel J
2014-07-01
This work demonstrates the ability of a bacterial concentration and recovery procedure combined with three different PCR assays targeting the lacZ, wecG, and 16S rRNA genes, respectively, to detect the presence of total coliforms in 100-ml samples of potable water (presence/absence test). PCR assays were first compared to the culture-based Colilert and MI agar methods to determine their ability to detect 147 coliform strains representing 76 species of Enterobacteriaceae encountered in fecal and environmental settings. Results showed that 86 (58.5%) and 109 (74.1%) strains yielded a positive signal with Colilert and MI agar methods, respectively, whereas the lacZ, wecG, and 16S rRNA PCR assays detected 133 (90.5%), 111 (75.5%), and 146 (99.3%) of the 147 total coliform strains tested. These assays were then assessed by testing 122 well water samples collected in the Québec City region of Canada. Results showed that 97 (79.5%) of the samples tested by culture-based methods and 95 (77.9%), 82 (67.2%), and 98 (80.3%) of samples tested using PCR-based methods contained total coliforms, respectively. Consequently, despite the high genetic variability of the total coliform group, this study demonstrated that it is possible to use molecular assays to detect total coliforms in potable water: the 16S rRNA molecular assay was shown to be as efficient as recommended culture-based methods. This assay might be used in combination with an Escherichia coli molecular assay to assess drinking water quality. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
Molecular Method for Detection of Total Coliforms in Drinking Water Samples
Boudreau, Dominique K.; Bisson, Marc-Antoine; Dion-Dupont, Vanessa; Bouchard, Sébastien; Nkuranga, Martine; Bergeron, Michel G.; Rodriguez, Manuel J.
2014-01-01
This work demonstrates the ability of a bacterial concentration and recovery procedure combined with three different PCR assays targeting the lacZ, wecG, and 16S rRNA genes, respectively, to detect the presence of total coliforms in 100-ml samples of potable water (presence/absence test). PCR assays were first compared to the culture-based Colilert and MI agar methods to determine their ability to detect 147 coliform strains representing 76 species of Enterobacteriaceae encountered in fecal and environmental settings. Results showed that 86 (58.5%) and 109 (74.1%) strains yielded a positive signal with Colilert and MI agar methods, respectively, whereas the lacZ, wecG, and 16S rRNA PCR assays detected 133 (90.5%), 111 (75.5%), and 146 (99.3%) of the 147 total coliform strains tested. These assays were then assessed by testing 122 well water samples collected in the Québec City region of Canada. Results showed that 97 (79.5%) of the samples tested by culture-based methods and 95 (77.9%), 82 (67.2%), and 98 (80.3%) of samples tested using PCR-based methods contained total coliforms, respectively. Consequently, despite the high genetic variability of the total coliform group, this study demonstrated that it is possible to use molecular assays to detect total coliforms in potable water: the 16S rRNA molecular assay was shown to be as efficient as recommended culture-based methods. This assay might be used in combination with an Escherichia coli molecular assay to assess drinking water quality. PMID:24771030
The application of the hazard analysis and control points (HACCP) in an ice cream production plant.
El-Tawila, M M
1998-01-01
The HACCP system is applied in the present study as a preventive food safety approach to control some hazards appearing in one of the ice cream production plants in Egypt. The problem comprised the presence of bacteriological and some chemical contamination in most of the company products. Before applying the HACCP system, the samples examination showed high total mesophilic plat count in 50% of the samples and high coliform count in all samples compared to the level recommended in the Egyptian standards. The highest staphylococcal count (negative for coagulase test) obtained was that of chocolate (1.3 x 10(4) CFU/g) followed by mango ice cream (l.0 x 10(4) CFU/g). Faecal coliform was only positive in mango ice cream. Additionally, the levels of lead, iron and copper have been determined. Copper was higher than the recommended level in all samples and ranged between 0.46 ppm in pistachio ice cream and 2.48 ppm in chocolate ice cream. Most of the CCPs in the ice cream production were mainly due to improper handling and practices throughout the processing steps and also related to the lack of food hygiene knowledge of the workers. The application of HACCP system has successfully reduced the bacteriological hazards in all samples. After applying the corrective actions, the highest total aerobic plate count (8.0 x 10(4)) was that of Swiss chocolate ice cream which corresponds to 50% of the recommended level by the Egyptian standards. Coliform count was less than 10 in all samples except mango ice cream (43 MPN). A significant decrease in staphylococcal count, faecal coliform and trace metal contamination was also recorded in all samples.
Chlorine disinfection of grey water for reuse: effect of organics and particles.
Winward, Gideon P; Avery, Lisa M; Stephenson, Tom; Jefferson, Bruce
2008-01-01
Adequate disinfection of grey water prior to reuse is important to prevent the potential transmission of disease-causing microorganisms. Chlorine is a widely utilised disinfectant and as such is a leading contender for disinfection of grey water intended for reuse. This study examined the impact of organics and particles on chlorine disinfection of grey water, measured by total coliform inactivation. The efficacy of disinfection was most closely linked with particle size. Larger particles shielded total coliforms from inactivation and disinfection efficacy decreased with increasing particle size. Blending to extract particle-associated coliforms (PACs) following chlorine disinfection revealed that up to 91% of total coliforms in chlorinated grey water were particle associated. The organic concentration of grey water affected chlorine demand but did not influence the disinfection resistance of total coliforms when a free chlorine residual was maintained. Implications for urban water reuse are discussed and it is recommended that grey water treatment systems target suspended solids removal to ensure removal of PACs prior to disinfection.
40 CFR 142.63 - Variances and exemptions from the maximum contaminant level for total coliforms.
Code of Federal Regulations, 2010 CFR
2010-07-01
... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS IMPLEMENTATION Identification of Best Technology, Treatment Techniques or Other Means Generally...
Liu, Wen-Cheng; Chan, Wen-Ting
2015-12-01
Climate change is one of the key factors affecting the future microbiological water quality in rivers and tidal estuaries. A coupled 3D hydrodynamic and fecal coliform transport model was developed and applied to the Danshuei River estuarine system for predicting the influences of climate change on microbiological water quality. The hydrodynamic and fecal coliform model was validated using observational salinity and fecal coliform distributions. According to the analyses of the statistical error, predictions of the salinity and the fecal coliform concentration from the model simulation quantitatively agreed with the observed data. The validated model was then applied to predict the fecal coliform contamination as a result of climate change, including the change of freshwater discharge and the sea level rise. We found that the reduction of freshwater discharge under climate change scenarios resulted in an increase in the fecal coliform concentration. The sea level rise would decrease fecal coliform distributions because both the water level and the water volume increased. A reduction in freshwater discharge has a negative impact on the fecal coliform concentration, whereas a rising sea level has a positive influence on the fecal coliform contamination. An appropriate strategy for the effective microbiological management in tidal estuaries is required to reveal the persistent trends of climate in the future.
Carrillo, M; Estrada, E; Hazen, T C
1985-01-01
The density of Bifidobacterium spp., fecal coliforms, Escherichia coli, and total anaerobic bacteria, acridine orange direct counts, percentages of total bacterial community activity and respiration, and 12 physical and chemical parameters were measured simultaneously at six sites for 12 months in the Mameyes River rain forest watershed, Puerto Rico. The densities of all bacteria were higher than those reported for uncontaminated temperate rivers, even though other water quality parameters would indicate that all uncontaminated sites were oligotrophic. The highest densities for all indicator bacteria were at the site receiving sewage effluent; however, the highest elevation site in the watershed had the next highest densities. Correlations between bacterial densities, nitrates, temperature, phosphates, and total phosphorus indicated that all viable counts were related to nutrient levels, regardless of the site sampled. In situ diffusion chamber studies at two different sites indicated that E. coli could survive, remain physiologically active, and regrow at rates that were dependent on nutrient levels of the ambient waters. Bifidobacterium adolescentis did not survive at either site but did show different rates of decline and physiological activity at the two sites. Bifidobacteria show promise as a better indicator of recent fecal contamination in tropical freshwaters than E. coli or fecal coliforms; however, the YN-6 medium did not prove to be effective for enumeration of bifidobacteria. The coliform maximum contaminant levels for assessing water usability for drinking and recreation appear to be unworkable in tropical freshwaters. PMID:3901921
Rosas, I; Báez, A; Coutiño, M
1984-01-01
Xochimilco county plots (Mexico City), one of the most fertile agricultural areas in the Valley of Mexico, produce a large portion of the fresh vegetables consumed in the city. These plots are generally irrigated with domestic wastewater, and for this reason, it was deemed important to examine and evaluate the bacteriological quality of the water, soil, and vegetables from these plots that are harvested and marketed. The soils were also examined for the classical parameters such as nitrates, ammonia, etc., and organic matter and texture. The crops selected for this study were radishes, spinach, lettuce, parsley, and celery because they are usually consumed raw. The highest bacterial counts were encountered in leafy vegetables, i.e., spinach (8,700 for total coliform and 2,400 for fecal coliform) and lettuce (37,000 for total coliform and 3,600 for fecal coliform). Statistically significant differences in bacterial counts between rinsed and unrinsed edible portions of the crops were observed even in rinsed vegetables, and high densities of fecal coliform were detected, indicating that their consumption represents a potential health hazard. The total coliform values found in irrigation water ranged from 4 X 10(4) to 29 X 10(4), and for fecal coliform the values ranged from 5 X 10(2) to 30 X 10(2). PMID:6742825
Rosas, I; Báez, A; Coutiño, M
1984-05-01
Xochimilco county plots (Mexico City), one of the most fertile agricultural areas in the Valley of Mexico, produce a large portion of the fresh vegetables consumed in the city. These plots are generally irrigated with domestic wastewater, and for this reason, it was deemed important to examine and evaluate the bacteriological quality of the water, soil, and vegetables from these plots that are harvested and marketed. The soils were also examined for the classical parameters such as nitrates, ammonia, etc., and organic matter and texture. The crops selected for this study were radishes, spinach, lettuce, parsley, and celery because they are usually consumed raw. The highest bacterial counts were encountered in leafy vegetables, i.e., spinach (8,700 for total coliform and 2,400 for fecal coliform) and lettuce (37,000 for total coliform and 3,600 for fecal coliform). Statistically significant differences in bacterial counts between rinsed and unrinsed edible portions of the crops were observed even in rinsed vegetables, and high densities of fecal coliform were detected, indicating that their consumption represents a potential health hazard. The total coliform values found in irrigation water ranged from 4 X 10(4) to 29 X 10(4), and for fecal coliform the values ranged from 5 X 10(2) to 30 X 10(2).
Total Coliform Rule Distribution System Advisory Committee (TCRDSAC) Document
This document provide information about the TCRDSAC, including its charter, processes and recommendations. The Agency used the Advisory Committee recommendations to develop proposed and final rules that revised the Total Coliform Rule.
Revised Total Coliform Rule Lab Sampling Form
This form should be completed when a water system collects any required Revised Total Coliform Rule (RTCR) samples. It should also be used when collecting “Special” non-compliance samples for the RTCR.
Revised Total Coliform Webinar for Primacy Agencies
This webinar was created to assist Primacy Agencies in the implementation of the Revised Total Coliform Rule. It provides an overview of the requirements in the rule and implementation guidance for Primacy Agencies.
Al-Bachir, Mahfouz
2017-01-01
Microbial contamination levels and corresponding sensitivities to gamma rays (GR) and elec- tron beam (EB) irradiation were tested in chamomile (Chamomile recutta L.). Chamomile powders were treated with 10 and 20 kGy by GR and EB, respectively. Microbiological and chemical analyses were performed on controls and treated samples immediately after irradiation, and after 12 months of storage. The control samples of chamomile exhibited rather high microbiological contamination, exceeding the levels of 4 log10 CFU g-1 (CFU - colony forming units) reported by national and international authorities as the maximum permissible total count level. Irradiation with GR and EB was found to cause a reduction in microbial contamination proportionate to the dose delivered. The sterilizing effect of EB on microorganisms was higher than the GR one. A dose of 10 kGy of GR and EB significantly (p < 0.05) reduced the total bacte- rial, total coliform and total fungal contamination. A dose of 20 kGy of GR significantly (p < 0.05) reduced the total bacterial and total fungal contamination, while a 20 kGy dose of EB reduced the initial bacterial, total coliform and total fungal contamination to below detection level when the analysis was carried out im- mediately after irradiation treatment or after 12 months of storage. The comparative study demonstrated that electron beam was more effective for decontamination of chamomile powder than gamma irradiation.
Removal of total coliform and E. coli using zeliac as filter media
NASA Astrophysics Data System (ADS)
Ibrahim, Nurazim; Aziz, Hamidi Abdul; Yusoff, Mohd Suffian
2017-10-01
High loading of wastewater and surface run off into river contributed to large amount of microorganisms entering drinking water sources. The aim of this study was to investigate the capability of composite adsorbent namely Zeliac to remove total coliform and E. coli from river water using fixed bed column experiment. Two ranges of Zeliac particle sizes (1.18- 2 mm and 0.425- 0.6 mm) were applied to observe the effect of particle size on the removal of the selected pollutants. Kerian River water with a total coliform and E. coli concentration of 14, 082 ± 4, 209 and 208 ± 166 MPN/100 mL respectively was continuously supplied to the column at constant flow rate of 20 (Column A) and 21 ml/min (Column B) for 991 hours. The presence of total coliform and E. coli in the treated water were detected using Colilert test kit from IDEXX Corporation. The performance of Zeliac as filter media was analysed by a breakthrough curve plotted from normalized concentration (C/Co) against time. It was discovered that a difference in particle size does not give a significant impact to the removal of total coliform and E. coli in this system. According to the plotted breakthrough curves, Zeliac as filter media was capable to immobilize total coliform and E. coli for up to 31 hours of contact time. This finding shows that Zeliac has the potential to retain pathogenic microorganism such as E. coli in a continuous fluid flow.
Mallin, Michael A; Johnson, Virginia L; Ensign, Scott H
2009-12-01
Water quality data at 12 sites within an urban, a suburban, and a rural stream were collected contemporaneously during four wet and eight dry periods. The urban stream yielded the highest biochemical oxygen demand (BOD), orthophosphate, total suspended sediment (TSS), and surfactant concentrations, while the most rural stream yielded the highest total organic carbon concentrations. Percent watershed development and percent impervious surface coverage were strongly correlated with BOD (biochemical oxygen demand), orthophosphate, and surfactant concentrations but negatively with total organic carbon. Excessive fecal coliform abundance most frequently occurred in the most urbanized catchments. Fecal coliform bacteria, TSS, turbidity, orthophosphate, total phosphorus, and BOD were significantly higher during rain events compared to nonrain periods. Total rainfall preceding sampling was positively correlated with turbidity, TSS, BOD, total phosphorus, and fecal coliform bacteria concentrations. Turbidity and TSS were positively correlated with phosphorus, fecal coliform bacteria, BOD, and chlorophyll a, which argues for better sedimentation controls under all landscape types.
USDA-ARS?s Scientific Manuscript database
Three assays were developed to enumerate total coliforms, Escherichia coli, and total Vibrionaceae in shellfish and other foods and in seawater and other environmental samples. Assays involve membrane overlays of overnight colonies on non-selective agar plates to detect ß-glucuronidase and lysyl am...
Coliphages as indicators of enteroviruses.
Stetler, R E
1984-01-01
Coliphages were monitored in conjunction with indicator bacteria and enteroviruses in a drinking-water plant modified to reduce trihalomethane production. Coliphages could be detected in the source water by direct inoculation, and sufficient coliphages were detected in enterovirus concentrates to permit following the coliphage levels through different water treatment processes. The recovery efficiency by different filter types ranged from 1 to 53%. Statistical analysis of the data indicated that enterovirus isolates were better correlated with coliphages than with total coliforms, fecal coliforms, fecal streptococci, or standard plate count organisms. Coliphages were not detected in finished water. PMID:6093694
NASA Astrophysics Data System (ADS)
Suhartono, S.; Ismail, Y. S.; Yulvizar, C.; Nursanty, R.; Mahyuddin, M.; Jannah, M.
2018-03-01
Of aquatic environment, antibiotic resistant bacteria, including total coliforms and E. coli disseminate and emerge at an alarming rate. The study aims to determine enumerate, isolate,E. coliand determine their antibiotic resistance and compare between those which were recovered from residentials and home industries in Banda Aceh and its surrounding area. The bacterial density and antibiotic susceptibility of total coliforms and E. coli were determined using Standard Total Coliform Multiple-Tube (MPN) Fermentation method and the disk diffusion method, respectively. Despite there was no significant difference of total coliforms and E. coli population between residentials and home industries (P > 0.05) in this study, their density as well as prevalence remained high in the water sample. This might expose serious health risks since the resistance might be easily spread acquired through horizontal gene transfer within the aquatic environment.
Laboratory investigation of drinking water sources of Kangra, Himachal Pradesh.
Thakur, S D; Panda, A K
2012-06-01
A total of 70 drinking water sources including piped water supply (n = 36), ground water sources (n = 24, hand pumps and bore wells) and natural water sources (n = 10, springs/step-wells) from various parts of district Kangra, Himachal Pradesh were investigated for their suitability for drinking purpose by presumptive coliform test. Three samples were collected from each source during different parts of the year. Piped water sources (91.7%) were most contaminated followed by natural water sources (90%) and ground water sources (62.5%). 70.5% of the total water samples (n = 210) were positive for coliforms. All the three samples from 8.3% (n = 3), 37.5% (n = 9) and 10% (n = 1) piped water, ground water and natural sources respectively, were negative for coliform organisms. A variety of organisms including Proteus, Klebsiella, Citrobacter, Escherichia coli (E. coli), Pasteurella, Enterobacter and Serratia liquefaciens were isolated from water samples positive for coliforms in presumptive coliform test. Thermo-tolerant coliform organisms; Escherichia coli, Citrobacter, Klebsiella and Enterobacter were 71.2% (n = 52) of the total bacterial isolations. These findings suggest absence of adequate treatment and disinfection of the water sources supplying drinking water in district Kangra.
Bacteria and Nutrients in the Obhur Recreational Sharm, Jeddah, Saudi Arabia
NASA Astrophysics Data System (ADS)
Turki, Adnan; Mudarris, Mohammed
2013-04-01
Environmental pollution that render waters along the recreational shore unsatisfactory for use by the general public has become a global health problem. This study was carried out to examine the marine waters in sampling stations located at Sharm Obhur (North of Jeddah). These parameters included: total coliform (TC), l fecal coliform (FC) and nutrients (NO2-N, NO3-N, NH4-N and PO4-P). A comparison of the mean values of nutrients in Sharm Obhur with those of other locations in the Red Sea suggests that the mean levels of nutrients were similar to those of unpolluted areas. TC and FC counts were higher at the north sampling stations than the south ones, and with little variations between their numbers. FC was not recovered at stations to the south. The study shows that TC and FC counts at all sampling stations similar to the levels reported for normal unpolluted sea water. Keywords: Pollution, Nutrients, Coliforms, Sharm Obhur, Red Sea.
Moyer, Douglas; Hyer, Kenneth
2003-01-01
Impairment of surface waters by fecal coliform bacteria is a water-quality issue of national scope and importance. Section 303(d) of the Clean Water Act requires that each State identify surface waters that do not meet applicable water-quality standards. In Virginia, more than 175 stream segments are on the 1998 Section 303(d) list of impaired waters because of violations of the water-quality standard for fecal coliform bacteria. A total maximum daily load (TMDL) will need to be developed by 2006 for each of these impaired streams and rivers by the Virginia Departments of Environmental Quality and Conservation and Recreation. A TMDL is a quantitative representation of the maximum load of a given water-quality constituent, from all point and nonpoint sources, that a stream can assimilate without violating the designated water-quality standard. Blacks Run, in Rockingham County, Virginia, is one of the stream segments listed by the State of Virginia as impaired by fecal coliform bacteria. Watershed modeling and bacterial source tracking were used to develop the technical components of the fecal coliform bacteria TMDL for Accotink Creek. The Hydrological Simulation Program?FORTRAN (HSPF) was used to simulate streamflow, fecal coliform concentrations, and source-specific fecal coliform loading in Blacks Run. Ribotyping, a bacterial source tracking technique, was used to identify the dominant sources of fecal coliform bacteria in the Blacks Run watershed. Ribotyping also was used to determine the relative contributions of specific sources to the observed fecal coliform load in Blacks Run. Data from the ribotyping analysis were incorporated into the calibration of the fecal coliform model. Study results provide information regarding the calibration of the streamflow and fecal coliform bacteria models and also identify the reductions in fecal coliform loads required to meet the TMDL for Blacks Run. The calibrated streamflow model simulated observed streamflow characteristics with respect to total annual runoff, seasonal runoff, average daily streamflow, and hourly stormflow. The calibrated fecal coliform model simulated the patterns and range of observed fecal coliform bacteria concentrations. Observed fecal coliform bacteria concentrations during low-flow periods ranged from 40 to 7,000 colonies per 100 milliliters, and peak concentrations during storm-flow periods ranged from 33,000 to 260,000 colonies per 100 milliliters. Simulated source-specific contributions of fecal coliform bacteria to instream load were matched to the observed contributions from the dominant sources, which were cats, cattle, deer, dogs, ducks, geese, horses, humans, muskrats, poultry, raccoons, and sheep. According to model results, a 95-percent reduction in the current fecal coliform load delivered from the watershed to Blacks Run would result in compliance with the designated water-quality goals and associated TMDL.
Moyer, Douglas; Hyer, Kenneth
2003-01-01
Impairment of surface waters by fecal coliform bacteria is a water-quality issue of national scope and importance. Section 303(d) of the Clean Water Act requires that each State identify surface waters that do not meet applicable water-quality standards. In Virginia, more than 175 stream segments are on the 1998 Section 303(d) list of impaired waters because of violations of the water-quality standard for fecal coliform bacteria. A total maximum daily load (TMDL) will need to be developed by 2006 for each of these impaired streams and rivers by the Virginia Departments of Environmental Quality and Conservation and Recreation. A TMDL is a quantitative representation of the maximum load of a given water-quality constituent, from all point and nonpoint sources, that a stream can assimilate without violating the designated water-quality standard. Accotink Creek, in Fairfax County, Virginia, is one of the stream segments listed by the State of Virginia as impaired by fecal coliform bacteria. Watershed modeling and bacterial source tracking were used to develop the technical components of the fecal coliform bacteria TMDL for Accotink Creek. The Hydrological Simulation Program?FORTRAN (HSPF) was used to simulate streamflow, fecal coliform concentrations, and source-specific fecal coliform loading in Accotink Creek. Ribotyping, a bacterial source tracking technique, was used to identify the dominant sources of fecal coliform bacteria in the Accotink Creek watershed. Ribotyping also was used to determine the relative contributions of specific sources to the observed fecal coliform load in Accotink Creek. Data from the ribotyping analysis were incorporated into the calibration of the fecal coliform model. Study results provide information regarding the calibration of the streamflow and fecal coliform bacteria models and also identify the reductions in fecal coliform loads required to meet the TMDL for Accotink Creek. The calibrated streamflow model simulated observed streamflow characteristics with respect to total annual runoff, seasonal runoff, average daily streamflow, and hourly stormflow. The calibrated fecal coliform model simulated the patterns and range of observed fecal coliform bacteria concentrations. Observed fecal coliform bacteria concentrations during low-flow periods ranged from 25 to 800 colonies per 100 milliliters, and peak concentrations during storm-flow periods ranged from 19,000 to 340,000 colonies per 100 milliliters. Simulated source-specific contributions of fecal coliform bacteria to instream load were matched to the observed contributions from the dominant sources, which were cats, deer, dogs, ducks, geese, humans, muskrats, and raccoons. According to model results, an 89-percent reduction in the current fecal coliform load delivered from the watershed to Accotink Creek would result in compliance with the designated water-quality goals and associated TMDL.
Human enteroviruses in oysters and their overlying waters.
Goyal, S M; Gerba, C P; Melnick, J L
1979-01-01
The presence of enteroviruses in oysters and oyster-harvesting waters of the Texas Gulf coast was monitored over a period of 10 months. Viruses were detected in water and oyster samples obtained from areas both open and closed to shellfish harvesting. Viruses were detected periodically in waters that met current bacteriological standards for shellfish harvesting. No significant statistical relationship was demonstrated between virus concentration in oysters and the bacteriological and physiochemical quality of water and shellfish. Viruses in water were, however, moderately correlated with total coliforms in water and oysters and with fecal coliforms in oysters. Total coliforms in water were realted to total coliforms in sediment were related only to total coliforms in sediment. Among the physiochemical characteristics of water, turbidity was related statistically to the organic matter content of water and to fecal coliforms in water. There was a marked effect of rainfall on the bacteriological quality of water. Of a total of 44 water samples, 26 yielded virus in concentrations from 4 to 167 plaque-forming units per 100-gallon (ca. 378.5-liter) sample. Of a total of 40 pools of 10 to 12 oysters each, virus was found in 14 pools at a concentration of 6 to 224 plaque-forming units per 100 g of oyster meat. On five occasions, virus was found in water samples when no virus could be detected in oysters harvested from the same sites. This study indicates that current bacteriological standards for determining the safety of shellfish and shellfish-growing waters do no reflect the occurrence of enteroviruses. PMID:222210
Human enteroviruses in oysters and their overlying waters.
Goyal, S M; Gerba, C P; Melnick, J L
1979-03-01
The presence of enteroviruses in oysters and oyster-harvesting waters of the Texas Gulf coast was monitored over a period of 10 months. Viruses were detected in water and oyster samples obtained from areas both open and closed to shellfish harvesting. Viruses were detected periodically in waters that met current bacteriological standards for shellfish harvesting. No significant statistical relationship was demonstrated between virus concentration in oysters and the bacteriological and physiochemical quality of water and shellfish. Viruses in water were, however, moderately correlated with total coliforms in water and oysters and with fecal coliforms in oysters. Total coliforms in water were realted to total coliforms in sediment were related only to total coliforms in sediment. Among the physiochemical characteristics of water, turbidity was related statistically to the organic matter content of water and to fecal coliforms in water. There was a marked effect of rainfall on the bacteriological quality of water. Of a total of 44 water samples, 26 yielded virus in concentrations from 4 to 167 plaque-forming units per 100-gallon (ca. 378.5-liter) sample. Of a total of 40 pools of 10 to 12 oysters each, virus was found in 14 pools at a concentration of 6 to 224 plaque-forming units per 100 g of oyster meat. On five occasions, virus was found in water samples when no virus could be detected in oysters harvested from the same sites. This study indicates that current bacteriological standards for determining the safety of shellfish and shellfish-growing waters do no reflect the occurrence of enteroviruses.
Praveena, Sarva Mangala; Chen, Kwan Soo; Ismail, Sharifah Norkhadijah Syed
2013-11-15
This study aims to determine the concentrations of total coliforms and Escherichia coli (E. coli) in beach water, Teluk Kemang beach. This study was also aimed to determine relationship between total coliforms, E. coli and physicochemical parameters. As perceived health symptoms among beach visitors are rarely incorporated in beach water studies, this element was also assessed in this study. A total of eight water sampling points were selected randomly along Teluk Kemang beach. Total coliforms concentrations were found between 20 and 1940 cfu/100ml. E. coli concentrations were between 0 and 90 cfu/100ml. Significant correlations were found between total coliforms and E. coli with pH, temperature and oxidation reduction potential. Skin and eyes symptoms were the highest reported though in small numbers. Microbiological water quality in Teluk Kemang public beach was generally safe for recreational activities except sampling location near with sewage outfall. Copyright © 2013 Elsevier Ltd. All rights reserved.
Public Notification Instructions and Templates for the Revised Total Coliform Rule (RTCR)
EPA has developed public notification (PN) templates to help with implementation of the PN Rule. This document aims to assist water systems with the Public Notification requirements specific to the Revised Total Coliform Rule (RTCR).
40 CFR 141.405 - Reporting and recordkeeping for ground water systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... to the State within 30 days of the total coliform positive sample that it met the State criteria. (b... system(s) of total-coliform positive samples that are not invalidated under § 141.21(c). Documentation...
40 CFR 141.405 - Reporting and recordkeeping for ground water systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... to the State within 30 days of the total coliform positive sample that it met the State criteria. (b... system(s) of total-coliform positive samples that are not invalidated under § 141.21(c). Documentation...
40 CFR 141.405 - Reporting and recordkeeping for ground water systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... to the State within 30 days of the total coliform positive sample that it met the State criteria. (b... system(s) of total-coliform positive samples that are not invalidated under § 141.21(c). Documentation...
Revised Total Coliform Rule Implementation in Wyoming and on Tribal Lands in EPA Region 8
The Revised Total Coliform Rule (RTCR) aims to increase public health protection through the reduction of potential pathways for fecal contamination in the distribution system of a public water system (PWS).
Shelton, D R; Pachepsky, Y A; Kiefer, L A; Blaustein, R A; McCarty, G W; Dao, T H
2014-08-01
As sediments increasingly become recognized as reservoirs of indicator and pathogen microorganisms, an understanding of the persistence of indicator organisms becomes important for assessment and predictions of microbial water quality. The objective of this work was to observe the response of water column and sediment coliform populations to the change in nutrient concentrations in the water column. Survival experiments were conducted in flow-through chambers containing sandy sediments. Bovine feces were collected fresh and introduced into sediment. Sixteen days later, the same fecal material was autoclaved and diluted to provide three levels - 1×, 0.5×, and 0.1× of nutrient concentrations - spike in water column. Total coliforms, Escherichia coli, and total aerobic heterotrophic bacterial concentrations were monitored in water and sediment. Bacteria responded to the nutrient spike with initial growth both in the water column and in sediment. The response of bacterial concentrations in water column was nonlinear, with no significant changes at 0.1 and .5× spikes, but a substantial change at 1× spike. Bacteria in sediment responded to the spikes at all added nutrient levels. Coliform inactivation rates both in sediment and in water after the initial growth occurred, were not significantly different from the inactivation rates before spike. These results indicate that introduction of nutrients into the water column results in nonlinear response of E. coli concentrations both in water and in sediments, followed by the inactivation with the same rate as before introduction of nutrients. Published by Elsevier Ltd.
Health significance and occurrence of injured bacteria in drinking water
NASA Technical Reports Server (NTRS)
McFeters, G. A.; LeChevallier, M. W.; Singh, A.; Kippin, J. S.
1986-01-01
Enteropathogenic and indicator bacteria become injured in drinking water with exposure to sublethal levels of various biological, chemical and physical factors. One manifestation of this injury is the inability to grow and form colonies on selective media containing surfactants. The resulting underestimation of indicator bacteria can lead to a false estimation of water potability. m-T7 medium was developed specifically for the recovery of injured coliforms (both "total" and fecal) in drinking water. The m-T7 method was used to survey operating drinking water treatment and distribution systems for the presence of injured coliforms that were undetected with currently used media. The mean recovery with m-Endo LES medium was less than 1/100 ml while it ranged between 6 and 68/100ml with m-T7 agar. The majority of samples giving positive results with m-T7 medium yielded no detectable coliforms with m-Endo LES agar. Over 95% of the coliform bacteria in these samples were injured. Laboratory experiments were also done to ascribe the virulence of injured waterborne pathogens. Enteropathogens including Salmonella typhimurium, Yersinia enterocolitica and Shigella spp. required up to 20 times the chlorine levels to produce the same injury in enterotoxigenic Escherichia coli (ETEC) and nonpathogenic coliforms. Similar results were seen with Y. enterocolitica exposed to copper. The recovery of ETEC was followed by delayed enterotoxin production, both in vitro and in the gut of experimental animals. This indicates that injured waterborne enteropathogenic bacteria can be virulent.
A Revised Total Coliform Rule Guide for Small Public Water Systems
This document aims to assist small water systems serving 1,000 persons with fewer in complying with the requirements of the Revised Total Coliform Rule (RTCR). It is divided into four parts, Parts A, B, C and D.
40 CFR 141.405 - Reporting and recordkeeping for ground water systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... to the State within 30 days of the total coliform positive sample that it met the State criteria. (b... system(s) of total coliform-positive samples that are not invalidated under § 141.21(c) until March 31...
Moyer, Douglas; Hyer, Kenneth
2003-01-01
Impairment of surface waters by fecal coliform bacteria is a water-quality issue of national scope and importance. Section 303(d) of the Clean Water Act requires that each State identify surface waters that do not meet applicable water-quality standards. In Virginia, more than 175 stream segments are on the 1998 Section 303(d) list of impaired waters because of violations of the water-quality standard for fecal coliform bacteria. A total maximum daily load (TMDL) will need to be developed by 2006 for each of these impaired streams and rivers by the Virginia Departments of Environmental Quality and Conservation and Recreation. A TMDL is a quantitative representation of the maximum load of a given water-quality constituent, from all point and nonpoint sources, that a stream can assimilate without violating the designated water-quality standard. Christians Creek, in Augusta County, Virginia, is one of the stream segments listed by the State of Virginia as impaired by fecal coliform bacteria. Watershed modeling and bacterial source tracking were used to develop the technical components of the fecal coliform bacteria TMDL for Christians Creek. The Hydrological Simulation Program?FORTRAN (HSPF) was used to simulate streamflow, fecal coliform concentrations, and source-specific fecal coliform loading in Christians Creek. Ribotyping, a bacterial source tracking technique, was used to identify the dominant sources of fecal coliform bacteria in the Christians Creek watershed. Ribotyping also was used to determine the relative contributions of specific sources to the observed fecal coliform load in Christians Creek. Data from the ribotyping analysis were incorporated into the calibration of the fecal coliform model. Study results provide information regarding the calibration of the streamflow and fecal coliform bacteria models and also identify the reductions in fecal coliform loads required to meet the TMDL for Christians Creek. The calibrated streamflow model simulated observed streamflow characteristics with respect to total annual runoff, seasonal runoff, average daily streamflow, and hourly stormflow. The calibrated fecal coliform model simulated the patterns and range of observed fecal coliform bacteria concentrations. Observed fecal coliform bacteria concentrations during low-flow periods ranged from 40 to 2,000 colonies per 100 milliliters, and peak concentrations during stormflow periods ranged from 23,000 to 730,000 colonies per 100 milliliters. Additionally, fecal coliform bacteria concentrations were generally higher upstream and lower downstream. Simulated source-specific contributions of fecal coliform bacteria to instream load were matched to the observed contributions from the dominant sources, which were beaver, cats, cattle, deer, dogs, ducks, geese, horses, humans, muskrats, poultry, raccoons, and sheep. According to model results, a 96-percent reduction in the current fecal coliform load delivered from the watershed to Christians Creek would result in compliance with the designated water-quality goals and associated TMDL.
Invik, Jesse; Barkema, Herman W; Massolo, Alessandro; Neumann, Norman F; Checkley, Sylvia
2017-10-01
With increasing stress on our water resources and recent waterborne disease outbreaks, understanding the epidemiology of waterborne pathogens is crucial to build surveillance systems. The purpose of this study was to explore techniques for describing microbial water quality in rural drinking water wells, based on spatiotemporal analysis, time series analysis and relative risk mapping. Tests results for Escherichia coli and coliforms from private and small public well water samples, collected between 2004 and 2012 in Alberta, Canada, were used for the analysis. Overall, 14.6 and 1.5% of the wells were total coliform and E. coli-positive, respectively. Private well samples were more often total coliform or E. coli-positive compared with untreated public well samples. Using relative risk mapping we were able to identify areas of higher risk for bacterial contamination of groundwater in the province not previously identified. Incorporation of time series analysis demonstrated peak contamination occurring for E. coli in July and a later peak for total coliforms in September, suggesting a temporal dissociation between these indicators in terms of groundwater quality, and highlighting the potential need to increase monitoring during certain periods of the year.
This memorandum provides guidance to primacy agencies with enforcement responsibility under the Safe Drinking Water Act (SDWA) concerning the requirements to transition public water systems (PWSs) from the Total Coliform Rule (TCR) to the RTCR
Fernández-Rendón, Carlos L; Barrera-Escorcia, Guadalupe
2013-01-01
The need to separate bacteria from sediment in order to appropriately count them has led to test the efficacy of different techniques. In this research, traditional techniques such as manual shaking, homogenization, ultrasonication, and surfactant are compared. Moreover, the possibility of using a set of enzymes (pancreatine) and an antibiotic (ampicillin) for sediment coliform extraction is proposed. Samples were obtained from Xochimilco Lake in Mexico City. The most probable number of coliform bacteria was determined after applying the appropriate separation procedure. Most of the techniques tested led to numbers similar to those of the control (manual shaking). Only with the use of ampicillin, a greater total coliform concentration was observed (Mann-Whitney, z = 2.09; p = 0.03). It is possible to propose the use of ampicillin as a technique for total coliform extraction; however, it is necessary to consider sensitivity of bacteria to the antibiotic.
An Environmental Health Assessment: Fecal Coliform Contamination in San Francisco Waterbodies
NASA Astrophysics Data System (ADS)
Devillier, K. N.; Devine, M.; Negrete, R.; Rawley, A. L.; Neiss, J.
2007-12-01
Fecal coliform is a group of bacteria that exists in the digestive system and excrement of warm-blooded animals. It enters aquatic environments through fecal contamination of water. In the urban environment, contamination can occur not only by direct input from warm-blooded animals but also from storm water run-off and municipal sewer overflow. Fecal coliform itself does not cause disease but it is an indicator of the presence of pathogens that exist in the wastes of humans and animals that are a hazard to human health. We examined 12 locations in San Francisco for fecal coliform and recorded the types of human contact with water at each location. We found low levels of coliform in areas open to the San Francisco Bay and Pacific Ocean and high levels of coliform in inland lakes and ponds. Using Environmental Protection Agency guidelines for fecal coliform concentrations, we found all sites at acceptable levels for the recreational and human activities we observed.
Examination and characterization of distribution system biofilms.
LeChevallier, M W; Babcock, T M; Lee, R G
1987-01-01
Investigations concerning the role of distribution system biofilms on water quality were conducted at a drinking water utility in New Jersey. The utility experienced long-term bacteriological problems in the distribution system, while treatment plant effluents were uniformly negative for coliform bacteria. Results of a monitoring program showed increased coliform levels as the water moved from the treatment plant through the distribution system. Increased coliform densities could not be accounted for by growth of the cells in the water column alone. Identification of coliform bacteria showed that species diversity increased as water flowed through the study area. All materials in the distribution system had high densities of heterotrophic plate count bacteria, while high levels of coliforms were detected only in iron tubercles. Coliform bacteria with the same biochemical profile were found both in distribution system biofilms and in the water column. Assimilable organic carbon determinations showed that carbon levels declined as water flowed through the study area. Maintenance of a 1.0-mg/liter free chlorine residual was insufficient to control coliform occurrences. Flushing and pigging the study area was not an effective control for coliform occurrences in that section. Because coliform bacteria growing in distribution system biofilms may mask the presence of indicator organisms resulting from a true breakdown of treatment barriers, the report recommends that efforts continue to find methods to control growth of coliform bacteria in pipeline biofilms. Images PMID:3435140
Public Notification - Revised Total Coliform Rule Failure To Report Template
When a PWS fails to report their monitoring results for Total Coliform bacteria, it must issue a public notice to inform consumers of its water of that failure to report. This template can be used as a guide for preparing that public notice.
Microbiological quality of fresh nopal juice
USDA-ARS?s Scientific Manuscript database
Microbial quality of commercially available fresh juices (n=162) made with nopal cactus in Texcoco, State of Mexico, was evaluated during the summer and spring season. All samples contained total coliforms and 91% were positive for Escherichia coli. Although total coliforms and E. coli were detected...
33 CFR 159.319 - Fecal coliform and total suspended solids standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... suspended solids standards. 159.319 Section 159.319 Navigation and Navigable Waters COAST GUARD, DEPARTMENT... Certain Alaskan Waters by Cruise Vessel Operations § 159.319 Fecal coliform and total suspended solids... solids greater than 150 mg/l. (b) Graywater effluent discharges. [Reserved] ...
33 CFR 159.319 - Fecal coliform and total suspended solids standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... suspended solids standards. 159.319 Section 159.319 Navigation and Navigable Waters COAST GUARD, DEPARTMENT... Certain Alaskan Waters by Cruise Vessel Operations § 159.319 Fecal coliform and total suspended solids... solids greater than 150 mg/l. (b) Graywater effluent discharges. [Reserved] ...
Maheux, Andrée F; Dion-Dupont, Vanessa; Bouchard, Sébastien; Bisson, Marc-Antoine; Bergeron, Michel G; Rodriguez, Manuel J
2015-06-01
The MI agar, Colilert(®), Chromocult coliform(®) agar, and DC with BCIG agar chromogenic culture-based methods used to assess microbiological quality of drinking water were compared in terms of their ubiquity, sensitivity, ease of use, growth of atypical colonies and affordability. For ubiquity, 129 total coliform (representing 76 species) and 19 Escherichia coli strains were tested. Then, 635 1-L well water samples were divided into 100 mL subsamples for testing by all four methods. Test results showed that 70.5, 52.7, 36.4, and 23.3% of the non-E. coli total coliform strains and 94.7, 94.7, 89.5, and 89.5% of the 19 E. coli strains yielded a positive signal with the four methods, respectively. They also yielded a total coliform positive signal for 66.5, 51.7, 64.9, and 55.0% and an E. coli positive signal for 16.1, 14.8, 17.3, and 13.4% of the 635 well water samples tested, respectively. Results showed that Colilert(®) is the most expensive method tested in terms of reactants, yet it is the easiest to use. Large numbers of atypical colonies were also often observed on Chromocult coliform(®) and DC with BCIG, thereby challenging the target microorganism count. Thus, the MI agar method seems to be the best option for the assessment of drinking water quality.
40 CFR 141.853 - General monitoring requirements for all public water systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Coliform Rule § 141.853 General monitoring requirements for all public water systems. (a) Sample siting... 31, 2016. These plans are subject to State review and revision. Systems must collect total coliform... MCL violation or has exceeded the coliform treatment technique triggers in § 141.859(a). (4) A system...
Cabral, João Paulo; Marques, Cristina
2006-07-01
Febros river water was sampled weekly, during 35 successive weeks, and analyzed for microbiological (total coliforms, faecal coliforms, faecal streptococci and enterococci) and chemical-physical (ammonia and temperature) parameters. All microbiological parameters were highly correlated with each other and with ammonia, suggesting that the simultaneous determination of all variables currently in use in the evaluation of the microbiological quality of waters is probably redundant, and could be simplified, and that ammonia should be tested as a sentinel parameter of the microbiological pollution load of Febros river. From the strains isolated from positive tubes of the faecal coliforms test (multiple tube fermentation technique) and retested in this assay, Escherichia coli, Klebsiella oxytoca and Klebsiella pneumoniae subsp. pneumoniae strains were positive, indicating that the faecal coliforms test is not totally specific for Escherichia coli, and can detect other bacteria. Considering that these Klebsiella spp. are not necessarily of faecal origin, it was concluded that the faecal coliforms test can overestimate true faecal pollution. From the strains isolated from positive tubes of the faecal coliforms procedure, only Escherichia coli strains were clearly positive in the beta-D-glucuronidase test. All other species were negative or very weakly positive, suggesting that the assay of the beta-D-glucuronidase activity is less prone to false positives than the faecal coliforms test in the quantification of Escherichia coli in environmental waters.
Abu Amr, S S; Yassin, M M
2008-11-01
To assess total and faecal coliform contamination in water wells and distribution networks over the past 7 years, and their association with human health in Khan Yunis Governorate, Gaza Strip. Historical data and interview questionnaire. Data were obtained from the Palestinian Ministry of Health on total and faecal coliform contamination in water wells and distribution networks, and on the incidence of water-related diseases in Khan Yunis Governorate. An interview questionnaire was conducted with 210 residents of Khan Yunis Governorate. Total and faecal coliform contamination exceeded the World Health Organization's limit for water wells and networks. However, the contamination percentages were higher in networks than in wells. Diarrhoeal diseases were strongly correlated with faecal coliform contamination in water networks (r=0.98). This is consistent with the finding that diarrhoeal diseases were the most common self-reported diseases among the interviewees. Such diseases were more prevalent among subjects who drank municipal water than subjects who drank desalinated or home-filtered water (odds ratio=2.03). Intermittent water supply, insufficient chlorination and sewage flooding seem to be associated with self-reported diseases. Residents in the Gaza Strip have a good level of knowledge about drinking water contamination, and this is reflected in good practice. Water quality has deteriorated in the Gaza Strip, and this may contribute to the prevalence of water-related diseases. Self-reported diseases among interviewees in Khan Yunis Governorate were associated with source of drinking water, intermittent water supply, insufficient chlorination, sewage flooding and age of water networks.
75 FR 18205 - Total Coliform Rule Revisions-Notice of Stakeholder Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-09
... Coliform Rule (RTCR) and the Distribution Systems Research and Information Collection Partnership... reviewing the methods approved to analyze drinking water samples to determine the presence of total... ( [email protected] , (202) 564-1781, Standards and Risk Management Division, Office of Ground Water and...
Microbial diversity in dental unit waterlines.
Lisboa, Guacyra M; Lisboa, Yves R M; Pinheiro, Telma M L; Stegun, Roberto C; da Silva-Filho, Eurípedes A
2014-01-01
Dental health care providers and patients are exposed during ongoing work to contamination by the water used in the dental units, due to accidental swallowing or aspiration of the sprays generated by the high-speed handpiece and the threeway syringe. This study evaluated the quality of water in dental units in the public dental care system of Maceio, Alagoas, Brazil, by conducting analyses of contamination by total coliforms, E.Coli, heterotrophic bacteria and filamentous fungi. We collected 200 mL of water at 5 sites in 6 dental offices of the Department of Health located in different parts of the city. A total 212 isolates and 16 genera of filamentous fungi were identified in the water collected from the dental units. Total coliforms indicated that the water used in dental units was not appropriate for human consumption. The high levels of contamination found in this study showed that water was a potential source of cross-infection.
Navab-Daneshmand, Tala; Enayet, Samia; Gehr, Ronald; Frigon, Dominic
2014-10-01
Electro-dewatering (ED) increases biosolids dryness from 10-15 to 30-50%, which helps wastewater treatment facilities control disposal costs. Previous work showed that high temperatures due to Joule heating during ED inactivate total coliforms to meet USEPA Class A biosolids requirements. This allows biosolids land application if the requirements are still met after the storage period between production and application. In this study, we examined bacterial regrowth and odour emissions during the storage of ED biosolids. No regrowth of total coliforms was observed in ED biosolids over 7d under aerobic or anaerobic incubations. To mimic on-site contamination during storage or transport, ED samples were seeded with untreated sludge. Total coliform counts decreased to detection limits after 4d in inoculated samples. Olfactometric analysis of ED biosolids odours showed that odour concentrations were lower compared to the untreated and heat-treated control biosolids. Furthermore, under anaerobic conditions, odorous reduced sulphur compounds (methanethiol, dimethyl sulphide and dimethyl disulphide) were produced by untreated and heat-treated biosolids, but were not detected in the headspaces above ED samples. The data demonstrate that ED provides advantages not only as a dewatering technique, but also for producing biosolids with lower microbial counts and odour levels. Copyright © 2014 Elsevier Ltd. All rights reserved.
Microbial quality of some vegetables sold in ED DueimTwon, Sudan.
Goja, Arafat Mohammed; Mahmoud, Mohamed Salih Osman
2013-06-15
This study was probably the first research carried out to investigate the microbiological quality of some vegetables sold in ED DueimTwon, Sudan. Four species of vegetables were used, Arugula (Eruca sativa), Mloukhia (Corchorus olitorius), Tomato (Lycopersicon esculentum) and Green pepper (Capsicum annuum). The samples were collected and examined according to standardized methods for total viable bacteria, coliforms and fecal coliform count. The average of total viable count ranged from 1.2 x 105-5.6 x 105 CFU mL(-1) for Arugula; 2.1 x 105-2.8 x 107 CFU mL(-1) for Mloukhia; 3.4 x 105-4.8 x 105 for Tomato and 2.3 x 105-8.0 x 106 CFU mL(-1) for Green pepper. However, the maximum level of total and fecal coliform were (93, 21); (28, 11); (75, 15) and (150, 20) MPN 100 mL(-1), respectively. Twelve bacteria belonging to five genera were isolated. Staphylococcus (33%) was the most predominant isolated followed by Enterobacteriaceae (25%), Bacillus (17%) and Streptococcus (17%). Micrococcus (8%) was the least dominant isolated. The results of microbial counts of these vegetable samples in this study indicate that, the agricultural practices, harvesting, hygiene, transporting and selling points are poor and therefore, the higher microbial load could be risked for public health.
THE TOTAL COLIFORM RULE AND FUTURE OF THE INDICATORS AND PATHOGENS IN DRINKING WATER ASSESSMENT
This presentation describes some of the major microbiological issues related to drinking water quality of concern to the EPA. The revision process of the Total Coliform Rule and the selection of the Microbial Contaminant List (CCL) are discussed. A brief overview of research co...
75 FR 14607 - Small Entity Compliance Guide: Bottled Water: Total Coliform and E. coli
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-26
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-D-0141] Small Entity Compliance Guide: Bottled Water: Total Coliform and E. coli; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and Drug Administration (FDA) is announcing...
Total Coliform Determinations. Training Module 5.205.3.77.
ERIC Educational Resources Information Center
Kirkwood Community Coll., Cedar Rapids, IA.
This document is an instructional module package prepared in objective form for use by an instructor familiar with multiple tube and membrane filter techniques for determining total coliform concentration of a water supply. Included are objectives, instructor guides, student handouts and transparency masters. This module considers proper…
USDA-ARS?s Scientific Manuscript database
The fecal coliform, Escherichia coli, is a historical organism for the detection of fecal pollution in water supplies. The presence of E. coli indicates a potential contamination of the water supply by other more hazardous human pathogens. In order to accurately determine the presence and degree o...
Code of Federal Regulations, 2013 CFR
2013-07-01
... WATER REGULATIONS Revised Total Coliform Rule § 141.856 Routine monitoring requirements for subpart H... coliform-positive sample taken under the provisions of this section, systems must comply with the repeat... coliform treatment technique triggers specified in § 141.859 have been exceeded. If any trigger has been...
Kim, Jung Hyun; Hur, Sun Jin; Yim, Dong Gyun
2018-04-01
This research was to evaluate microbial contamination levels in meat samples at hazard analysis critical control point (HACCP)-implemented processing plants that produce beef, pork, and chicken. During a period of about a year, a total of 178 samples (76 from beef, 89 from pork, and 13 from chicken) were obtained from raw materials (21.3%) and final products (78.7%). All samples were determined for each 25 g homogenized one. Samples were analyzed to determine the total aerobic plate count (APC), coliform count (CC), and E. coli count (ECC). By month, APC levels were the highest in September and the lowest in February ( p <0.001). In comparison among season, APC levels in meat samples were the highest in the summer and the lowest in winter ( p <0.001). By month, the highest CC prevalence was found in August, followed by October and then July ( p <0.001). By season, the highest CC was obtained in summer, followed by autumn and then spring ( p <0.001). All samples were negative for ECC. There was a direct correlation between the product form and coliform presence ( p <0.001). In addition, there was a positive correlation between the APC and CC (r=0.261). The APCs in analyzed samples ranged from below <10 1 CFU/g to <10 7 CFU/g. In conclusion, the month and season had significant effects on microbial contamination levels at HACCP implemented processing plants. Interrelationships between (i) the product form and coliform, (ii) the APC and CC were revealed.
Lopez, Adrián Avendaño; Villa, Carolina Arguedas
2006-09-01
We measured microcystin levels in water of the Metropolitan Area of Costa Rica by competitive inhibition ELISA and we quantified total coliforms, fecal coliforms, Escherichia coli (by a Most Probable Number method) and aerobic count. We wanted to identify any cyanotoxin correlation with these parameters, as a public health risk. We sampled in the rainy season of 2003 (April-October) and in the dry season of 2004 (February-March) (30 samples/season). We sampled pre-treated, semi-treated and treated water. Microcystin levels < 0.5 ppb were found in the rainy season (and > 0.5 ppb in the dry season). Dry season levels exceeded World Health Organization limits (1.0 ppb). Cyanotoxins occurred in the Tres Rios plant. We did not find a correlation between these microbiologic parameters of water quality and microcystin levels in water.
Greve, Josephine D; Zietlow, Mark S; Miller, Kevin M; Ellingson, Jay L E
2015-09-01
A total of 720 whole, romaine lettuce heads were purchased from retail locations in the Upper Midwest and assessed for coliform and Escherichia coli contamination and for the presence of E. coli O157:H7. During a 16-month period (August 2010 through December 2011), coliform and E. coli counts were enumerated on Petrifilm, and the presence of E. coli O157:H7 and the virulence gene eae was evaluated by real-time PCR (qPCR). Over half (400 of 720) of the lettuce samples were processed with an immunomagnetic separation step before the qPCR assay. All retail lettuce samples were negative for E. coli O157:H7 when tested with the R.A.P.I.D. LT qPCR targeting a region of the O-antigen, and only two (0.28%) were positive for the eae gene when tested with LightCycler qPCR. On Petrifilm, coliform counts of most lettuce samples (96.4%) were between <10(1) and 10(3) CFU/g, and E. coli counts for nearly all lettuce samples (98.2%) were <10(1) CFU/g. No seasonal trend in coliform and E. coli counts was observed throughout the examination period nor was a difference in coliform counts observed between packaged and nonpackaged lettuce heads. These results contribute to the limited recorded data and understanding of microbial contamination of whole romaine lettuce heads purchased from retail locations, specifically revealing the absence of E. coli O157:H7 and low levels of contamination with coliforms and other E. coli strains.
Kassenga, Gabriel R
2007-03-01
The consumption of bottled and plastic-bagged drinking water in Tanzania has increased largely because of the deteriorating quality of tap water. It is uncertain whether these water products are safe for drinking. In this study, the microbiological quality of bottled and plastic-bagged drinking water sold in Dar es Salaam, Tanzania, was investigated. One hundred and thirty samples representing 13 brands of bottled water collected from shops, supermarkets and street vendors were analysed for total coliform and faecal coliform organisms as well as heterotrophic bacteria. These were compared with 61 samples of tap water. Heterotrophic bacteria were detected in 92% of the bottled water samples analysed. Total and faecal coliform bacteria were present in 4.6% and 3.6%, respectively, of samples analysed with a tendency for higher contamination rates in plastic-bagged drinking water. Microbiological quality of tap water was found to be worse compared with bottled water, with 49.2% and 26.2% of sampling points showing the presence of total coliform and faecal coliform organisms, respectively. The results suggest caution and vigilance to avert outbreaks of waterborne diseases from these types of drinking water.
Bacteriology of Dehydrated Space Foods 1
Powers, Edmund M.; Ay, Carl; El-Bisi, Hamed M.; Rowley, Durwood B.
1971-01-01
The initial bacteriological requirement established in 1964 for space foods by the U.S. Army Natick Laboratories are: a total aerobic plate count (≤ 10,000 per g), a total coliform count (≤ 10 per g), fecal coliforms (negative per gram), fecal streptococci (≤ 20 per g), coagulase-positive staphylococci (negative in 5 g) and salmonellae (negative in 10 g). Of the space foods and prototypes tested during 1968 and 1969, 93% complied with the total aerobic plate count, 98% had less than 1 coliform per g, and 99% were negative for fecal coliforms; 88% complied with the streptococci requirement; 100 and 98% were negative for staphylococci and salmonellae, respectively. Nineteen food samples which did not comply (as indicated parenthetically by actual counts per gram) with the requirements were (i) total aerobic plate count: beef soup and gravy base (18,000), chicken soup and gravy base (57,000), spaghetti with meat sauce (12,100 and 14,000), sugared coffee (> 300,000), chocolate ice cream cubes (20,000), and each of four samples of chocolate candy (12,000 to 61,000); (ii) coliforms: two out of three vanilla milk drinks (16 and 127) and one beef hash bar (14); (iii) fecal coliforms: one sample of chicken soup and gravy base positive; (iv) fecal streptococci: two samples of peanut cubes (40 and 108), coconut cubes (75), chicken soup and gravy base (2,650), beef soup and gravy base (33), and five out of six flavored milk drinks (23 to 300); (v) salmonellae: one each of chicken and beef soup and gravy base were positive. Images PMID:4940878
The microbiological quality of drinking water sold on the streets in Kumasi, Ghana.
Obiri-Danso, K; Okore-Hanson, A; Jones, K
2003-01-01
The aim of this study was to assess the microbiological quality of Ghanaian bottled and plastic-bagged drinking water sold on the streets of Metropolitan Kumasi, Ghana. Eight bottled, 88 factory-filled plastic sachet and 40 hand-filled hand-tied polythene-bagged drinking waters were examined for the presence of heterotrophic bacteria total viable counts (TVCs), indicators of faecal contamination (total coliforms, faecal coliforms and enterococci) and for lead, manganese and iron. Heterotrophic bacteria were found in all three types of water with TVCs per millilitre ranging from 1 to 460 for bottled water, 2-6.33 x 10(5) for factory-bagged sachet water and 2.33 x 10(3)-7.33 x 10(12) for hand-filled hand-tied bagged water. None of the microbial indicators of faecal contamination were detected in bottled water, whereas 4.5% of the factory-bagged sachets contained total coliforms and 2.3% faecal coliforms, and 42.5% of the hand-filled hand-tied bags contained total coliforms, 22.5% faecal coliforms and 5% enterococci. Iron was found in all three types of drinking water but at concentrations well within the WHO recommendations. Lead and manganese were not detected. Ghanaian bottled water is of good microbiological quality but some factory-bagged sachet and hand-filled hand-tied polythene-bagged drinking water are of doubtful quality. Factory-bagged sachets and hand-filled hand-tied bags of drinking water sold in Ghana should be monitored for microbiological contamination, with the aim of raising standards in the industry and re-assuring the public.
Entry, J A; Farmer, N
2001-01-01
Large-scale deposition of animal manure can result in contamination of surface and ground water and in potential transfer of disease-causing enteric bacteria to animals or humans. We measured total coliform bacteria (TC), fecal coliform bacteria (FC), NO3, NH4, total P, and PO4 in ground water flowing from basalt and sand aquifers, in wells into basalt and sand aquifers, in irrigation water, and in river water. Samples were collected monthly for 1 yr. Total coliform and FC numbers were always higher in irrigation water than in ground water, indicating that soil and sediment filtered most of these bacteria before they entered the aquifers. Total coliform and FC numbers in ground water were generally higher in the faster flowing basalt aquifer than in the sand aquifer, indicating that the slower flow and finer grain size may filter more TC and FC bacteria from water. At least one coliform bacterium/100 mL of water was found in ground water from both basalt and sand aquifers, indicating that ground water pumped from these aquifers is not necessarily safe for human consumption according to the American Public Health Association and the USEPA. The NO3 concentrations were usually higher in water flowing from the sand aquifer than in water flowing from the basalt aquifer or in perched water tables in the basalt aquifer. The PO4 concentrations were usually higher in water flowing from the basalt aquifer than in water flowing from the sand aquifer. The main concern is fecal contamination of these aquifers and health consequences that may arise from human consumption.
Microbiological Food Safety Status of Commercially Produced Tomatoes from Production to Marketing.
van Dyk, Brigitte N; de Bruin, Willeke; du Plessis, Erika M; Korsten, Lise
2016-03-01
Tomatoes have been implicated in various microbial disease outbreaks and are considered a potential vehicle for foodborne pathogens. Traceback studies mostly implicate contamination during production and/or processing. The microbiological quality of commercially produced tomatoes was thus investigated from the farm to market, focusing on the impact of contaminated irrigation and washing water, facility sanitation, and personal hygiene. A total of 905 samples were collected from three largescale commercial farms from 2012 through 2014. The farms differed in water sources used (surface versus well) and production methods (open field versus tunnel). Levels of total coliforms and Escherichia coli and prevalence of E. coli O157:H7 and Salmonella Typhimurium were determined. Dominant coliforms were identified using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. No pathogens or E. coli were detected on any of the tomatoes tested throughout the study despite the high levels of coliforms (4.2 to 6.2 log CFU/g) present on the tomatoes at the market. The dominant species associated with tomatoes belonged to the genera Enterobacter, Klebsiella, and Citrobacter. Water used on the farm for irrigation considered not fit for purpose according to national agricultural irrigation standards, with high E. coli levels resulting from either a highly contaminated source water (river water at 3.19 log most probable number [MPN]/100 ml) or improper storage of source water (stored well water at 1.72 log MPN/100 ml). Salmonella Typhimurium was detected on two occasions on a contact surface in the processing facility of the first farm in 2012. Contact surface coliform counts were 2.9 to 4.8 log CFU/cm(2). Risk areas identified in this study were water used for irrigation and poor sanitation practices in the processing facility. Implementation of effective food safety management systems in the fresh produce industry is of the utmost importance to ensure product safety for consumers.
Methods for detecting total coliform bacteria in drinking water were compared using 1483 different drinking water samples from 15 small community water systems in Vermont and New Hampshire. The methods included the membrane filter (MF) technique, a ten tube fermentation tube tech...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-14
... Hwy Fecal Coliform. to entrance of White Bayou (East Baton Rouge Parish) (Scenic). 040103 Comite River--Entrance of White Fecal Coliform. Bayou to Amite River. 040201 Bayou Manchac--Headwaters to Fecal Coliform... Blind River--From Amite River TSS. Diversion Canal to mouth at Lake Maurepas (Scenic). 040903 Bayou Cane...
Smith, Tamara; Krometis, Leigh-Anne H; Hagedorn, Charles; Lawrence, Annie H; Benham, Brian; Ling, Erin; Ziegler, Peter; Marmagas, Susan West
2014-12-01
Over 1.7 million Virginians rely on private water sources to provide household water. The heaviest reliance on these systems occurs in rural areas, which are often underserved with respect to available financial resources and access to environmental health education. This study aimed to identify potential associations between concentrations of fecal indicator bacteria (FIB) (coliforms, Escherichia coli) in over 800 samples collected at the point-of-use from homes with private water supply systems and homeowner-provided demographic data (household income and education). Of the 828 samples tested, 349 (42%) of samples tested positive for total coliform and 55 (6.6%) tested positive for E. coli. Source tracking efforts targeting optical brightener concentrations via fluorometry and the presence of a human-specific Bacteroides marker via quantitative real-time polymerase chain reaction (qPCR) suggest possible contamination from human septage in over 20 samples. Statistical methods implied that household income has an association with the proportion of samples positive for total coliform, though the relationship between education level and FIB is less clear. Further exploration of links between demographic data and private water quality will be helpful in building effective strategies to improve rural drinking water quality.
1989-09-01
granitics is indicated by the Tungsten Peak Mine, which produced 180 acre-feetof waterper year when in operation. Besides evaporation from China Lake Playa ... coliform colonies /100 mL Fecal coliform colonies /100 mL Fecal streptococci colonies /100 mL Alkalinity: Carbonate mg/L Bicarbonate mg/L 3 Observations and...type and No. mg/L Sarometric pressure mm/Hg Calibration value mg/L Total coliform _ _ colonies /100 mL Fecal coliform colonies 1100 mLFwwl strelptocc
Olaoye, O A; Onilude, A A
2009-11-01
To assess the microbiological quality of sachet-packaged drinking water in Western Nigeria and its impact on public health. Cross-sectional microbiological testing. Ninety-two sachet-packaged water samples were analysed for microbiological and metal qualities. Total bacterial and coliform counts were determined, and the presence of Escherichia coli, an important water quality indicator, was tested. The level of conformity of the water processors with the guidelines of Nigeria's quality regulatory agency was also determined. Varying levels of microbial contamination were recorded in samples from the different sampling locations. The total bacteria count ranged between 2.86 and 3.45log colony-forming units (cfu)/ml. The highest coliform count recorded was 1.62log cfu/ml. Faecal coliform E. coli was detected in one sample from Oke-Iho and one sample from Okaka, representing 2.2% of total samples. Lead and manganese were not found in any of the samples. However, iron was detected and the highest iron concentration (0.10mg/l) was detected in samples from Ikorodu. The bacteria that were identified from the water samples included E. coli, Pseudomonas aeruginosa, Enterobacter aerogenes, Klebsiella sp., Proteus vulgaris, Alcaligenes faecalis, Bacillus cereus, Staphylococcus aureus, Streptococcus lactis, Aeromonas sp. and Micrococcus luteum. Many of the water processors did not comply with the guidelines of the quality regulatory agency. Some of the sachet-packaged samples of drinking water were of poor quality. The results indicate a need for Nigeria's quality regulatory agency to take appropriate measures in safeguarding public health.
Wilhelm, Lance J.; Maluk, Terry L.
1998-01-01
IntroductionHigh levels of fecal-indicator bacteria in rivers and streams can indicate the possible presence of pathogenic (disease-causing) microorganisms. Cholera, typhoid fever, bacterial dysentery, infectious hepatitis, and cryptosporidiosis are some of the well known waterborne diseases that spread through water contaminated and fecal matter. Eye, ear, nose, and throat infections also can result from contact with contaminated water. In general, methods are not routinely used to detect pathogens in water. Instead, bacteria such as total coliforms, fecal coliforms, fecal streptococci, Escherichia coli (E coli), and enterococci are used as indicators of sanitary water quality, because they are present in high numbers in fecal material and have been shown to be associated with some waterborne disease-causing organisms. Indicator bacteria usually are harmless, more plentiful, and easier to detect than pathogens. The concentration of bacteria in a sample of water is usually expressed as the number of bacterial colonies per 100 milliliters of water sample.As part of the U.S. Geological Survey National Water-Quality Assessment Program, 145 samples were collected and analyzed for selected water-quality constituents, fecal coliforms, and fecal streptococci at 17 sites in North and South Carolina from October 1995 through September 1996. Of the original 17 sites, 4 in South Carolina were sampled for E. coli and total coliforms from April through September 1997. At two sites, this sampling continued from October 1997 through April 1998.
Bacteriological quality of drinking water in Nyala, South Darfur, Sudan.
Abdelrahman, Amira Ahmed; Eltahir, Yassir Mohammed
2011-04-01
The objective of this study was to determine the bacterial contaminations in drinking water in Nyala city, South Darfur, Sudan with special reference to the internally displaced people camps (IDPs). Two hundred and forty water samples from different sites and sources including bore holes, hand pumps, dug wells, water points, water reservoir and household storage containers were collected in 2009. The most probable number method was used to detect and count the total coliform, faecal coliform and faecal enterococci. Results revealed that the three indicators bacteria were abundant in all sources except water points. Percentages of the three indicators bacteria count above the permissible limits for drinking water in all samples were 46.4% total coliform, 45.2% faecal coliform and 25.4% faecal enterococci whereas the highest count of the indicators bacteria observed was 1,600 U/100 ml water. Enteric bacteria isolated were Escherichia coli (22.5%), Enterococcus faecalis (20.42%), Klebsiella (15.00%), Citrobacter (2.1%) and Enterobacter (3.33%). The highest contamination of water sources was observed in household storage containers (20%) followed by boreholes (11.25%), reservoirs (6.24%), hand pumps (5.42%) and dug wells (2.49%). Contamination varied from season to season with the highest level in autumn (18.33%) followed by winter (13.75%) and summer (13.32%), respectively. All sources of water in IDP camps except water points were contaminated. Data suggested the importance of greater attention for household contamination, environmental sanitation control and the raise of awareness about water contamination.
On-farm and postharvest processing sources of bacterial contamination to melon rinds.
Gagliardi, J V; Millner, P D; Lester, G; Ingram, D
2003-01-01
Multistate and international foodborne illness outbreaks, particularly involving cantaloupe and often involving rare Salmonella spp., have increased dramatically over the past 13 years. This study assessed the sources and extent of melon rind contamination in production fields and at processing and packing facilities. In the spring of 1999, cantaloupe (Cucumis melo L. [reticulatus group] cv. Cruiser) sampled from two sites in the Rio Grande River Valley showed that postharvest-processed melon rinds often had greater plate counts of bacterial contaminants than field-fresh melons. Cantaloupe in the field had 2.5 to 3.5 log CFU g(-1) rind total coliforms by aerobic plate counts, whereas washed melons had 4.0 to 5.0 log CFU g(-1). In the fall of 1999, coliforms on honeydew melons (C. melo [inodorous group] cv. Honey Brew) ranged from 2.6 to 3.7 log CFU g(-1) after processing, and total and fecal coliforms and enterococci never fell below 2.5 log CFU g(-1). A hydrocooler at another site contaminated cantaloupe rinds with up to 3.4 log CFU g(-1) total and fecal enterococci; a secondary rinse with chlorinated water incompletely removed these bacteria. Sources of coliforms and enterococci were at high levels in melon production soils, especially in furrows that were flood irrigated, in standing water at one field, and in irrigation water at both sites. At one processing facility, wash water pumped from the Rio Grande River may not have been sufficiently disinfected prior to use. Because soil, irrigation water, and process water were potential sources of bacterial contamination, monitoring and management on-farm and at processing and packing facilities should focus on water quality as an important control point for growers and packers to reduce bacterial contamination on melon rinds.
Hill, Dagne D; Owens, William E; Tchounwou, Paul B
2005-04-01
The objective of this research was to compare the chemical/physical parameters and bacterial qualities of selected surface water streams in Louisiana, including a natural stream (control) and an animal waste related stream. Samples were collected and analyzed for fecal coliforms. Fecal coliforms isolated from these samples were identified to the species level. Chemical analysis was performed following standard test protocols (LaMotte 2002). An analysis of biological oxygen demand (BOD), chemical oxygen demand (COD), total organic carbon (TOC), total dissolved solids (TDS), conductivity, pH, temperature, ammonia nitrogen, nitrate nitrogen, iron, copper, phosphate, potassium, sulfate, turbidity, zinc and bacterial levels was performed following standard test protocols as presented in Standard Methods for the Examination of Water and Wastewater [9]. Results of the comparisons of the various surface water streams showed that phosphate levels, according to Mitchell and Stapp, were considered good for Lake Claiborne (control) and Bayou Dorcheat. The levels were found to be .001 mg/L and .007 mg/L respectively. Other streams associated with animal waste, had higher phosphate levels of 2.07 mg/L and 2.78 mg/L, respectively. Conductivity and total dissolved solids (TDS) levels were the lowest in Lake Claiborne and highest in the Hill Farm Research Station stream. It can be concluded from the data that some bacterial levels and various nutrient levels can be affected in water resources due to non-point source pollution. Many of these levels will remain unaffected.
Mugnai, Riccardo; Sattamini, Ana; Albuquerque dos Santos, José Augusto; Regua-Mangia, Adriana Hamond
2015-01-01
The Hyporheic Zone is among the most important interstitial freshwater habitats, but the relationship between biotic and abiotic factors in this zone remains under-explored. Enterobacteria were expected to be present, but no specific studies had ever confirmed this prediction. The aim of this study was, therefore, to evaluate the total coliforms, Escherichia coli and Salmonella spp. in hyporheic water and to determine the relationship of the physical, chemical and environmental factors at different depths in a rainforest stream. To this end, thirty-six water samples were collected at three depths in sites located in the first, second and third orders in diverse substrates. The total coliforms, Escherichia coli and Salmonella sp. were evaluated in terms of their CFU/ml. In the interstitial samples, coliforms were detected in 100% of the samples. The total coliform counts had higher values at intermediate depths, while E. coli and Salmonella spp. instead had higher values at intermediate and large depths, often reaching or exceeding the values of the surface samples. Our results revealed that Salmonella spp. and the coliforms have different microhabitat preferences. Salmonella spp. and coliform species prefer deposition areas, such as lateral sides of pools, curves and bars, but they have a tendency to distribute into different depths, likely due to temperature differences. Salmonella spp. prefer compact substrata, with fewer fluids passing through and with upwelling areas with lower oxygen inflow. The coliform species showed the opposite preference. Our results suggest that bacterial variation is related to environmental factors and physical-chemical parameters within the HZ and may play a key role in the microbial diversity and distribution in these ecosystems. PMID:26067288
Holding effects on coliform enumeration in drinking water samples.
McDaniels, A E; Bordner, R H; Gartside, P S; Haines, J R; Brenner, K P; Rankin, C C
1985-01-01
Standard procedures for analyzing drinking water stress the need to adhere to the time and temperature conditions recommended for holding samples collected for microbiological testing. The National Drinking Water Laboratory Certification Program requires compliance with these holding limits, but some investigators have reported difficulties in meeting them. Research was conducted by standard analytical methods to determine if changes occurred when samples were held at 5 and 22 degrees C and analyzed at 0, 24, 30, and 48 h. Samples were analyzed for coliforms by the membrane filter and fermentation-tube procedures and for heterotrophs by the pour plate method. A total of 17 treated water samples were collected from a large municipal distribution system from August to December 1981, and 12 samples were collected from January to May 1983. The samples were dosed with coliforms previously isolated from the water system, Enterobacter cloacae in 1981 and Citrobacter freundii in 1983. The coliform counts declined linearly over time, and the rates of decline were significant at both 5 and 22 degrees C. Within 24 h at 22 degrees C, levels of E. cloacae and C. freundii decreased by 47 and 26%, respectively, and at 5 degrees C, E. cloacae numbers declined by 23%. Results from these representative laboratory-grown coliforms reinforced those previously obtained with naturally occurring coliforms under the same experimental conditions. Significantly, some samples with initially unacceptable counts (greater than 4/100 ml) met the safe drinking water limits after storage at 24 h at 5 and 22 degrees C and would have been classified as satisfactory.(ABSTRACT TRUNCATED AT 250 WORDS) Images PMID:4083877
Photocatalytic degradation of E. coliform in water.
Sun, Darren Delai; Tay, Joo Hwa; Tan, Koh Min
2003-08-01
This study aims to further investigate the total mineralization of the bacteria to the extent of death and cell-mass inactivation using a TiO2-Fe2O3 membrane photocatalytic oxidation reactor. Experimental results clearly indicated that dissolved oxygen (DO), hydraulic retention time (HRT) and concentration of the model bacteria (Escherichia coliform) affected the removal efficiency. It was found that the ultimate removal efficiency was 99% at DO level of 21.34 mg/l, HRT at 60s and high concentration of E. coli at 10(9)CFU/ml. The morphologic studies also showed that E. coliform could be further mineralized into CO2 and H2O. Dissolved organic carbon, pH and gas chromatograph analysis had justified most importantly the evolution of CO2. Experimental results revealed that the photomineralization rate of E. coliform followed pseudo-first-order kinetics by the role of DO. The derived empirical models were found consistent with the proposed reaction pathways of a combined UV breakdown on mass cell and a dual-site Langmuir-Hinshelwood mechanism where the rate-controlling step is the surface interaction between the adsorbed cleavage bacterial cells and hydroxyl radicals.
Sanitary quality of the Jordan River in Salt Lake County, Utah
Thompson, K.R.
1984-01-01
This investigation of the sanitary quality of the Jordan River was conducted from July 1980 to October 1982 using indicator bacteria rather than specific pathogens. A serious sanitary problem was identified. Concentrations of total coliform bacteria often exceeded 5,000 colonies per 100 milliliters and concentrations of fecal coliform bacteria often exceeded 2,000 colonies per 100 milliliters in the lower reaches of the river. At times these levels were greatly exceeded. The most conspicuous aspect of the bacteriological data is its extreme variability. Seven waste-water treatment plants, seven major tributaries, numerous storm conduits, irrigation-return flow, and other sources all contribute to the dynamic system that determines the sanitary quality of the river. Because of this variability the sanitary quality of the river cannot be predicted at any one time. In general, concentrations of all three indicator bacteria increased in a downstream direction. Storm runoff from urban areas contributed large concentrations of indicator bacteria to the river. Regression analysis of 9 years of data collected at 1700 South Street showed a significant positive correlation between both fecal coliform and fecal streptococcal concentrations versus time. Concentrations of fecal coliform and fecal streptococci have both been increasing since 1974 at 1700 South Street. (USGS)
Şengül, Mustafa; Erkaya, Tuba; Aksakal, Vecihi
2017-01-01
The aim of this study was to investigate the effects of production systems and milk collection periods on the somatic cell count (SCC), some microbiological properties, total aerobic mesophilic bacteria (TAMB), coliform, Staphylococcus aureus (S. aureus), yeast and mould) and antibiotic residue of milk; in Turkey. Milk samples were collected from 9 conventional farms and 9 organic farms during one year time, at six different months (December 2013 to October 2014), and all farms were selected from the same geographical locations. All organically managed farms had organic production certificates given by the Republic of Turkey Ministry of Food, Agriculture and Livestock. The count of TAMB, coliform, and coagulase positive S. aureus were affected by production systems at the level of p<0.01; yeast and mold, and somatic cell count (SCC) were affected at the level of p<0.05. But, differences according to months were statistically significant only on TAMB (p<0.01) and coliform (p<0.05) counts. The general means of TAMB, coliform and yeast and mould counts of the organic milk (OM) were significantly lower (p<0.05), while the general means of SCC and coagulase positive S. aureus count of the OM was significantly higher (p<0.05) compared to conventional milk (CM). Antibiotic residue was determined in one of the CM sample and in two of the OM samples. Our study is the first research that compared conventional and organic milk in Turkey. This study indicated that the microbiological quality of OM was the higher in terms of TAMB, coliform and yeast and mould, whereas was the lower in relation to SCC and coagulase positive S. aureus counts. But, the quality of both milk types should be improved. PMID:28515650
40 CFR 141.805 - Notification to passengers and crew.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., repeat or follow-up total coliform-positive or E. coli-positive sample result in accordance with § 141... samples in response to a sample result that is E. coli-positive in accordance with § 141.803(g); (4... response to a sample result that is total coliform-positive and E. coli-negative in accordance with § 141...
40 CFR 141.805 - Notification to passengers and crew.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., repeat or follow-up total coliform-positive or E. coli-positive sample result in accordance with § 141... samples in response to a sample result that is E. coli-positive in accordance with § 141.803(g); (4... response to a sample result that is total coliform-positive and E. coli-negative in accordance with § 141...
Controls on the quality of harvested rainwater in residential systems
NASA Astrophysics Data System (ADS)
Sojka, S. L.; Phung, D.; Hollingsworth, C.
2014-12-01
Rainwater harvesting systems, in which runoff from roofs is collected and used for irrigation, toilets and other purposes, present a viable solution to limited freshwater supplies and excess stormwater runoff. However, a lack of data on the quality of harvested rainwater hinders adoption of rainwater harvesting systems and makes development of rainwater harvesting regulations difficult. We conducted monthly surveys of 6 existing residential rainwater harvesting systems ranging in age from 1 to 11 years measuring pH, temperature, dissolved oxygen, total suspended solids, dissolved organic carbon, and coliform bacteria. We also examined a subset of the samples for iron, lead, mercury and arsenic. Many of the systems routinely met the water quality requirements for non-potable use without additional treatment, which is often required by regulations. In addition, while previous studies have shown that roof runoff contains heavy metals, the water in all systems showed very low or undetectable levels of metal contamination. Coliform bacteria concentration ranged from 20 to greater than 1400 CFU's per 100 mL and correlated with total suspended solids, which ranged from 2 - 7 mg l-1. The relationship between suspended solids and bacteria population was confirmed in a controlled experiment on the impact of filtering the rainwater before storage. Filtration decreased total suspended solids and total coliforms and increased dissolved oxygen concentration. This project provides insight into the effects of system design and a baseline assessment of the quality of harvested rainwater in existing systems.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-31
.... The proposed revisions require systems that have an indication of coliform contamination in the... deaths due to potential fecal contamination and waterborne pathogen exposure. This proposal also...
Donkor, Eric S; Lanyo, R; Kayang, Boniface B; Quaye, Jonathan; Edoh, Dominic A
2010-09-01
The occurrence of pathogens in the internal parts of vegetables is usually associated with irrigation water or contaminated soil and could pose risk to consumers as the internalised pathogens are unaffected by external washing. This study was carried out to assess the rate of internalisation of microbes in common Ghanaian vegetables. Standard microbiological methods were employed in microbial enumeration of vegetables collected at the market and farm levels, as well as irrigation water and soil samples. The overall mean counts of vegetables were 4.0 x 10(3) cfu g(-1); 8.1 x 10(2) cfu g(-1); 2.0 x 10(2) cfu g(-1); 3.5 x 10(2) cfu g(-1) for total bacteria, coliform counts, faecal coliform counts and yeast counts, respectively. The rate of internalisation of coliforms in vegetables irrigated with stream/well water was 2.7 times higher than those irrigated with pipe water. The mean coliform counts (4.7 x 10(7) cfu g(-1)) and faecal coliform counts (1.8 x 10(6) cfu g(-1)) of soil samples were similar to those of stream water suggesting both sources exerted similar contamination rates on the vegetables. Generally, there were no significant variations between the rates of internalisation of microbes at the market and farm levels at p < 05, indicating that internalisation of microbes in the vegetables mainly occurred at the farm level. The study has shown that microbial contamination of vegetables in Ghana is not limited to the external surface, but internal vegetable parts could harbour high microbial loads and pose risk to consumers. Safety practices associated with the commodity should therefore not be limited to external washing only. There is the additional need of heating vegetables to eliminate microbes both externally and internally before consumption.
Evans, T M; LeChevallier, M W; Waarvick, C E; Seidler, R J
1981-01-01
The species of total coliform bacteria isolated from drinking water and untreated surface water by the membrane filter (MF), the standard most-probable-number (S-MPN), and modified most-probable-number (M-MPN) techniques were compared. Each coliform detection technique selected for a different profile of coliform species from both types of water samples. The MF technique indicated that Citrobacter freundii was the most common coliform species in water samples. However, the fermentation tube techniques displayed selectivity towards the isolation of Escherichia coli and Klebsiella. The M-MPN technique selected for more C. freundii and Enterobacter spp. from untreated surface water samples and for more Enterobacter and Klebsiella spp. from drinking water samples than did the S-MPN technique. The lack of agreement between the number of coliforms detected in a water sample by the S-MPN, M-MPN, and MF techniques was a result of the selection for different coliform species by the various techniques. PMID:7013706
Evaluation of Polymerase Chain Reaction for Detecting Coliform Bacteria in Drinking Water Sources.
Isfahani, Bahram Nasr; Fazeli, Hossein; Babaie, Zeinab; Poursina, Farkhondeh; Moghim, Sharareh; Rouzbahani, Meisam
2017-01-01
Coliform bacteria are used as indicator organisms for detecting fecal pollution in water. Traditional methods including microbial culture tests in lactose-containing media and enzyme-based tests for the detection of β-galactosidase; however, these methods are time-consuming and less specific. The aim of this study was to evaluate polymerase chain reaction (PCR) for detecting coliform. Totally, 100 of water samples from Isfahan drinking water source were collected. Coliform bacteria and Escherichia coli were detected in drinking water using LacZ and LamB genes in PCR method performed in comparison with biochemical tests for all samples. Using phenotyping, 80 coliform isolates were found. The results of the biochemical tests illustrated 78.7% coliform bacteria and 21.2% E. coli . PCR results for LacZ and LamB genes were 67.5% and 17.5%, respectively. The PCR method was shown to be an effective, sensitive, and rapid method for detecting coliform and E. coli in drinking water from the Isfahan drinking water sources.
The microbial quality of drinking water in Manonyane community: Maseru District (Lesotho).
Gwimbi, P
2011-09-01
Provision of good quality household drinking water is an important means of improving public health in rural communities especially in Africa; and is the rationale behind protecting drinking water sources and promoting healthy practices at and around such sources. To examine the microbial content of drinking water from different types of drinking water sources in Manonyane community of Lesotho. The community's hygienic practices around the water sources are also assessed to establish their contribution to water quality. Water samples from thirty five water sources comprising 22 springs, 6 open wells, 6 boreholes and 1 open reservoir were assessed. Total coliform and Escherichia coli bacteria were analyzed in water sampled. Results of the tests were compared with the prescribed World Health Organization desirable limits. A household survey and field observations were conducted to assess the hygienic conditions and practices at and around the water sources. Total coliform were detected in 97% and Escherichia coli in 71% of the water samples. The concentration levels of Total coliform and Escherichia coli were above the permissible limits of the World Health Organization drinking water quality guidelines in each case. Protected sources had significantly less number of colony forming units (cfu) per 100 ml of water sample compared to unprotected sources (56% versus 95%, p < 0.05). Similarly in terms of Escherichia coli, protected sources had less counts (7% versus 40%, p < 0.05) compared with those from unprotected sources. Hygiene conditions and practices that seemed to potentially contribute increased total coliform and Escherichia coli counts included non protection of water sources from livestock faeces, laundry practices, and water sources being down slope of pit latrines in some cases. These findings suggest source water protection and good hygiene practices can improve the quality of household drinking water where disinfection is not available. The results also suggest important lines of inquiry and provide support and input for environmental and public health programmes, particularly those related to water and sanitation.
NASA Technical Reports Server (NTRS)
April, G. C.; Liu, H. A.
1975-01-01
Total coliform group bacteria were selected to expand the mathematical modeling capabilities of the hydrodynamic and salinity models to understand their relationship to commercial fishing ventures within bay waters and to gain a clear insight into the effect that rivers draining into the bay have on water quality conditions. Parametric observations revealed that temperature factors and river flow rate have a pronounced effect on the concentration profiles, while wind conditions showed only slight effects. An examination of coliform group loading concentrations at constant river flow rates and temperature shows these loading changes have an appreciable influence on total coliform distribution within Mobile Bay.
A new membrane filter agar medium (MI agar) containing a chromogen, indoxyl-beta-D-glucuronide, and a fluorogen, 4-methylumbelliferyl-beta-D-galactopyranoside, was developed to simultaneously detect and enumerate Escherichia coli and total coliforms (TC) in water samples on the b...
[Spring water quality assessment regarding the problem of endemic fluorosis].
Leshchenko, D V; Mialo, O A; Beliakova, M B; Beliaeva, E A; Samoukina, A M; Chervinets, Iu V; Ivanova, O V
2013-01-01
A possible variant for reducing the consumption of fluoride by population of Tver region is the use of water with low fluoride content, such as spring water. Assessment of drinking suitability of spring water (the content of physiologically important mineral elements and microbial purity) is relevant to our region. Water samples from 6 spring-water source of Tver region were studied during the year. The content of fluoride and calcium were measured by using an ion-selective electrodes. Microbiological purity tested by the presence of total coliform bacteria, thermotolerant coliform bacteria, coliphages and total microbial numbers. The analysis of some mineral components in spring water of Tver region showed that calcium content was in range 33-88 mg/l, that satisfied the recommended value; fluoride concentration is less then 0.5 mg/l. In all spring water samples total coliforms, thermotolerant coliforms and coliphages were absent. The total microbial number was in standard range, except of two spring-water source in the autumn and summer. The data suppose that spring water of Tver region can be used as a component of diet normalizing the fluoride consumption at risk of dental fluorosis in children.
Escherichia coli and coliforms level of food utensils at food premises in Kuala Pilah, Malaysia
NASA Astrophysics Data System (ADS)
Saipullizan, Siti Nurul Ain; Mutalib, Sahilah Abd.; Sedek, Razalee
2018-04-01
The aim of this study was to evaluate the Escherichia coli and coliforms level of food utensils at sixty food premises in Kuala Pilah, Malaysia. The swab technique was used to investigate the presence of E. coli and coliforms on 180 of food utensils (chopping boards: 60, knives: 60 and dish plates: 60). The results indicated that 180 of food utensils were contaminated with E. coli and coliforms. More than 60% of the coliforms were exceeded the acceptable limit compared to E. coli on the food utensils. The one-way ANOVA analysis demonstrated that the presence of E. coli and coliforms differed significantly among the three types of food utensils (knives, chopping boards, and dish plates). In conclusion, this study revealed that there are hygiene issues exist in every food premises. The food utensils are safe to use during the food preparation if the presence of E. coli and coliforms are not exceed the acceptable limit. Thus, it is recommended that the food handlers in the food premises should improve effective cleaning and sanitizing of food utensils in their daily work.
Kumar, A Yudhistra; Reddy, M Vikram
2008-01-01
Most Probable Number (MPN) of Total Coliforms (TC) and Faecal Coliforms (FC), and the physicochemical variables - temperature, Dissolved Oxygen (D.O.), Biochemical Oxygen Demand (B.O.D.), Chemical Oxygen Demand (C.O.D.), nitrates, phosphates and chlorides of municipal raw sewage and that of aeration tank and secondary clarifier of the Sewage Treatment Plant (STP), in relation to water at the treated sewage out-fall point, down-stream and up-stream of the Buckingham Canal at Kalpakkam were analyzed. Total Coliform and Faecal Coliform MPN counts were higher, 170 and 70/100 mL respectively in the raw sewage. However, the counts of the former in the aeration tank though remained similar, that of FC decreased to 50/100 mL; both of the counts further decreased to 30 and 44/100 mL respectively, in the secondary clarifier and were 110 and 23/100 mL, respectively at the treated sewage out-fall point in the canal. Total coliforms MPN was more than 18 times less in the water at the up-stream than that of the treated sewage out-fall point in the canal. Interestingly MPN of the FC in the up-stream water was nil while it was 8/100 mL in the canal's down-stream point. It is concluded that the FC, B.O.D., C.O.D., nitrates, phosphates and chlorides decreased and the D.O. increased in the treated-sewage due to the treatment of raw sewage through the STP.
Reneau, R B; Pettry, D E; Shanholtz, M I; Graham, S A; Weston, C W
1977-01-01
Distribution of total and fecal coliform bacteria in three Atlantic coastal plain soils in Virginia were monitored in situ over a 3-year period. The soils studied were Varina, Goldsboro, and Beltsville sandy loams. These and similar soils are found extensively along the populous Atlantic seaboard of the United States. They are considered only marginally suitable for septic tank installation because the restricting soil layers result in the subsequent development of seasonal perched water tables. To determine both horizontal and vertical movement of indicator organisms, samples were collected from piezometers placed at selected distances and depths from the drainfields in the direction of the ground water flow. Large reductions in total and fecal coliform bacteria were noted in the perched ground waters above the restricting layers as distance from the drainfield increased. These restricting soil layers appear to be effective barriers to the vertical movement of indicator organisms. The reduction in the density of the coliform bacteria above the restricting soil layers can probably be attributed to dilution, filtration, and dieoff as the bacteria move through the natural soil systems. PMID:325589
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-23
... laboratory analysis as required by the EC of the finished product including: Total aerobic bacteria, coliforms (30 [deg]C), coliforms (44.5 [deg]C), anaerobic sulphite-reducing bacteria (no gas production...
33 CFR 159.309 - Limitations on discharge of treated sewage or graywater.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30-day period does not exceed 20 fecal coliform/100 milliliters (ml) and not more than 10 percent of the samples exceed 40 fecal coliform/100 ml; (4) Concentrations of total residual chlorine do not...
33 CFR 159.309 - Limitations on discharge of treated sewage or graywater.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30-day period does not exceed 20 fecal coliform/100 milliliters (ml) and not more than 10 percent of the samples exceed 40 fecal coliform/100 ml; (4) Concentrations of total residual chlorine do not...
Stauber, Christine E.; Walters, Adam; de Aceituno, Anna M. Fabiszewski; Sobsey, Mark D.
2013-01-01
There is growing evidence that household water treatment interventions improve microbiological water quality and reduce diarrheal disease risk. Few studies have examined, however, the impact of water treatment interventions on household-level hygiene and sanitation. This study examined the association of four water and sanitation conditions (access to latrines, improved sanitation, improved water and the plastic biosand filter) on the levels of total coliforms and E. coli on existing and introduced toys during an on-going randomized controlled trial of the plastic biosand filter (plastic BSF). The following conditions were associated with decreased bacterial contamination on children’s toys: access to a latrine, access to improved sanitation and access to the plastic BSF. Overall, compared to existing toys, introduced toys had significantly lower levels of both E. coli and total coliforms. Results suggest that levels of fecal indicator bacteria contamination on children’s toys may be associated with access to improved water and sanitation conditions in the home. In addition, the fecal indicator bacteria levels on toys probably vary with duration in the household. Additional information on how these toys become contaminated is needed to determine the usefulness of toys as indicators or sentinels of water, sanitation and hygiene conditions, behaviors and risks. PMID:23598302
Stauber, Christine E; Walters, Adam; Fabiszewski de Aceituno, Anna M; Sobsey, Mark D
2013-04-18
There is growing evidence that household water treatment interventions improve microbiological water quality and reduce diarrheal disease risk. Few studies have examined, however, the impact of water treatment interventions on household-level hygiene and sanitation. This study examined the association of four water and sanitation conditions (access to latrines, improved sanitation, improved water and the plastic biosand filter) on the levels of total coliforms and E. coli on existing and introduced toys during an on-going randomized controlled trial of the plastic biosand filter (plastic BSF). The following conditions were associated with decreased bacterial contamination on children's toys: access to a latrine, access to improved sanitation and access to the plastic BSF. Overall, compared to existing toys, introduced toys had significantly lower levels of both E. coli and total coliforms. Results suggest that levels of fecal indicator bacteria contamination on children's toys may be associated with access to improved water and sanitation conditions in the home. In addition, the fecal indicator bacteria levels on toys probably vary with duration in the household. Additional information on how these toys become contaminated is needed to determine the usefulness of toys as indicators or sentinels of water, sanitation and hygiene conditions, behaviors and risks.
Zimmerman, Tammy M.; Zimmerman, Michele L.; Lindsey, Bruce D.
2001-01-01
Total coliform and Escherichia coli (E. coli) bacteria were analyzed in ground water sampled from 78 private household-supply wells as part of a study by the U.S. Geological Survey in cooperation with the Pennsylvania Department of Environmental Protection to evaluate the relation between well construction characteristics and the occurrence of bacteria in ground water. Sampling was done in eight counties in south-central and southeastern Pennsylvania from September 2000 to March 2001. All samples were collected from wells in close proximity to agricultural land-use areas.Total coliform bacteria were found in water from 62 percent (48 of 78) of the wells, and bacteria were just as likely to be found in sanitary wells (grouted/loose-fitting well cap or grouted/sanitary sealed well cap) as in nonsanitary wells (nongrouted/ loose-fitting well cap). The areas underlain by carbonate bedrock had the highest percentages of total coliform detected (about 75 percent). Nearly half of the samples collected in the areas underlain by noncarbonate bedrock also were found to have total coliform present. E. coli bacteria were found in water from 10 percent of the wells. Seventeen percent of the samples that were positive for total coliform also were positive for E. coli. The presence of E. coli bacteria was more likely in water from nonsanitary wells. Additionally, the presence of E. coli bacteria was more likely in ground water from wells underlain by carbonate bedrock. A further breakdown of the data into four groups on the basis of sanitary construction and bedrock type indicated the presence of E. coli was more likely in water from nonsanitary wells in areas underlain by carbonate bedrock.Statistical analysis of other well-construction characteristics that might relate to occurrence of bacteria showed that the presence of total coliform bacteria was related to the depth to water-bearing zone in both sanitary and nonsanitary wells in areas underlain by carbonate bedrock. Relations also are present between the presence of total coliform bacteria and casing length in nonsanitary wells in areas underlain by noncarbonate bedrock. Bacteria were found in wells both with and without insects observed on the underside of the well cap. Because of the small number of wells sampled that had sanitary sealed caps, it is uncertain whether installation of sanitary sealed well caps would reduce the incidence of bacteria in ground water from wells or if the presence of bacteria is because of a combination of well-construction characteristics or aquifer-wide contamination of limited or broad areal extent.
Murphy, P; Dal Bello, F; O'Doherty, J; Arendt, E K; Sweeney, T; Coffey, A
2013-07-01
This study was designed to evaluate the effects of algal and yeast β-glucans on the porcine gastrointestinal microbiota, specifically the community of Lactobacillus, Bifidobacterium and coliforms. A total of 48 pigs were fed four diets over a 28-day period to determine the effect that each had on these communities. The control diet consisted of wheat and soya bean meal. The remaining three diets contained wheat and soya bean meal supplemented with β-glucan at 250 g/tonne from Laminaria digitata, Laminaria hyperborea or Saccharomyces cerevisiae. Faecal samples were collected from animals before feeding each diet and after the feeding period. The animals were slaughtered the following day and samples were collected from the stomach, ileum, caecum, proximal colon and distal colon. Alterations in Lactobacillus in the gastrointestinal tract (GIT) were analysed using denaturing gradient gel electrophoresis (DGGE) profiles generated by group-specific 16S rRNA gene PCR amplicons. Plate count analysis was also performed to quantify total coliforms. DGGE profiles indicated that all β-glucan diets provoked the emergence of a richer community of Lactobacillus. The richest community of lactobacilli emerged after feeding L. digitata (LD β-glucan). Plate count analysis revealed that the L. hyperborea (LH β-glucan) diet had a statistically significant effect on the coliform counts in the proximal colon in comparison with the control diet. β-glucan from L. digitata and S. cerevisiae also generally reduced coliforms but to a lesser extent. Nevertheless, the β-glucan diets did not significantly reduce levels of Lactobacillus or Bifidobacterium. DGGE analysis of GIT samples indicated that the three β-glucan diets generally promoted the establishment of a more varied range of Lactobacillus species in the caecum, proximal and distal colon. The LH β-glucan had the most profound reducing effect on coliform counts when compared with the control diet and diets supplemented with L. digitata and S. cerevisiae β-glucans.
Hand-pumps as reservoirs for microbial contamination of well water
Ferguson, Andrew S.; Mailloux, Brian J.; Ahmed, Kazi M.; van Geen, Alexander; McKay, Larry D.; Culligan, Patricia J.
2018-01-01
The retention and release of total coliforms and Escherichia coli was investigated in hand-pumps removed from tubewells tapping a faecally contaminated aquifer in Matlab, Bangladesh, and from a new hand-pump deliberately spiked with E. coli. All hand-pumps were connected to reservoirs of sterile water and flushed. Faecal coliforms were observed in the discharge from all three of the previously used hand-pumps, at concentrations comparable to levels measured in discharge when they were attached to the tubewells. During daily flushing of one of the previously used hand-pumps, the concentration of total coliforms in the discharge remained relatively constant (≈103 MPN/100 mL). Concentrations of E. coli in the pump discharge declined over time, but E. coli was still detectable up to 29 days after the start of flushing. In the deliberately spiked hand-pump, E. coli was observed in the discharge over 125 days (t50 = 8 days) and found to attach preferentially to elastomeric materials within the hand-pump. Attempts to disinfect both the village and new hand-pumps using shock chlorination were shown to be unsuccessful. These results demonstrate that hand-pumps can act as persistent reservoirs for microbial indicator bacteria. This could potentially influence drinking water quality and bias testing of water quality. PMID:22048430
Ye, Bixiong; Yang, Linsheng; Li, Yonghua; Wang, Wuyi; Li, Hairong
2013-01-01
Bacterial contamination of drinking water is a major public health problem in rural China. To explore bacterial contamination in rural areas of Beijing and identify possible causes of bacteria in drinking water samples, water samples were collected from wells in ten rural districts of Beijing, China. Total bacterial count, total coliforms and Escherichia coli in drinking water were then determined and water source and wellhead protection were investigated. The bacterial contamination in drinking water was serious in areas north of Beijing, with the total bacterial count, total coliforms and Escherichia coli in some water samples reaching 88,000 CFU/mL, 1,600 MPN/100 mL and 1,600 MPN/100 mL, respectively. Water source types, well depth, whether the well was adequately sealed and housed, and whether wellhead is above or below ground were the main factors influencing bacterial contamination levels in drinking water. The bacterial contamination was serious in the water of shallow wells and wells that were not closed, had no well housing or had a wellhead below ground level. The contamination sources around wells, including village dry toilets and livestock farms, were well correlated with bacterial contamination. Total bacterial counts were affected by proximity to sewage ditches and polluting industries, however, proximity to landfills did not influence the microbial indicators. PMID:23462436
Evaluation of Polymerase Chain Reaction for Detecting Coliform Bacteria in Drinking Water Sources
Isfahani, Bahram Nasr; Fazeli, Hossein; Babaie, Zeinab; Poursina, Farkhondeh; Moghim, Sharareh; Rouzbahani, Meisam
2017-01-01
Background: Coliform bacteria are used as indicator organisms for detecting fecal pollution in water. Traditional methods including microbial culture tests in lactose-containing media and enzyme-based tests for the detection of β-galactosidase; however, these methods are time-consuming and less specific. The aim of this study was to evaluate polymerase chain reaction (PCR) for detecting coliform. Materials and Methods: Totally, 100 of water samples from Isfahan drinking water source were collected. Coliform bacteria and Escherichia coli were detected in drinking water using LacZ and LamB genes in PCR method performed in comparison with biochemical tests for all samples. Results: Using phenotyping, 80 coliform isolates were found. The results of the biochemical tests illustrated 78.7% coliform bacteria and 21.2% E. coli. PCR results for LacZ and LamB genes were 67.5% and 17.5%, respectively. Conclusion: The PCR method was shown to be an effective, sensitive, and rapid method for detecting coliform and E. coli in drinking water from the Isfahan drinking water sources. PMID:29142893
Coliforms removal in full-scale activated sludge plants in India.
Kazmi, A A; Tyagi, V K; Trivedi, R C; Kumar, Arvind
2008-05-01
This paper investigates the removal of coliforms in full-scale activated sludge plants (ASP) operating in northern regions of India. Log2.2 and log2.4 removal were observed for total coliforms (TC) and fecal coliforms (FC), respectively. However, the effluent still contained a significant number of TC and FC which was greater than the permissible limit for unrestricted irrigation as prescribed by WHO. The observations also suggest that extended aeration (EA) process operating under high mixed liquor suspended solids (MLSS) and sludge retention time (SRT) is more efficient in the removal of coliforms. Further attempts have been made to establish the relationship between two key wastewater parameters, i.e. biochemical oxygen demand (BOD) and suspended solids (SS) with respect to fecal and TC. The relationships were observed to be linear with a good coefficient of correlation. The interrelationship of BOD and SS with coliforms manifest that improvement of the microbiological quality of wastewater could be linked with the removal of SS. Therefore, SS can serve as a regulatory tool in lieu of an explicit coliforms standard.
Harmon, S Michele; West, Ryan T; Yates, James R
2014-12-01
Sources of fecal coliform pollution in a small South Carolina (USA) watershed were identified using inexpensive methods and commonly available equipment. Samples from the upper reaches of the watershed were analyzed with 3M(™) Petrifilm(™) count plates. We were able to narrow down the study's focus to one particular tributary, Sand River, that was the major contributor of the coliform pollution (both fecal and total) to a downstream reservoir that is heavily used for recreation purposes. Concentrations of total coliforms ranged from 2,400 to 120,333 cfu/100 mL, with sharp increases in coliform counts observed in samples taken after rain events. Positive correlations between turbidity and fecal coliform counts suggested a relationship between fecal pollution and stormwater runoff. Antibiotic resistance analysis (ARA) compared antibiotic resistance profiles of fecal coliform isolates from the stream to those of a watershed-specific fecal source library (equine, waterfowl, canines, and untreated sewage). Known fecal source isolates and unknown isolates from the stream were exposed to six antibiotics at three concentrations each. Discriminant analysis grouped known isolates with an overall average rate of correct classification (ARCC) of 84.3 %. A total of 401 isolates from the first stream location were classified as equine (45.9 %), sewage (39.4 %), waterfowl (6.2 %), and feline (8.5 %). A similar pattern was observed at the second sampling location, with 42.6 % equine, 45.2 % sewage, 2.8 % waterfowl, 0.6 % canine, and 8.8 % feline. While there were slight weather-dependent differences, the vast majority of the coliform pollution in this stream appeared to be from two sources, equine and sewage. This information will contribute to better land use decisions and further justify implementation of low-impact development practices within this urban watershed.
Metropolitan Spokane Region Water Resources Study. Appendix A. Surface Water
1976-01-01
is adequate. Cnly phenols and detergents are reported in the pollutants category and no bacteriological tests are made. Since none of the other sources...Coliform, MPN Conf No/100ml 31507 Total Coliform, MPN Comp No/lO0ml 31615 Fecal Coliform, MPNECmED No/100ml 32730 Phenols ug/1l 38260 MBAS mg/l 70507...Oil & Grease, Pesticides, I Surfactants, Sulfite Waste Liquor, Phenols WATER RESOURCES STUDY METROPOLITAN SPOKANE REGION GROUPING OF WATER QUALITY
The presence-absence coliform test for monitoring drinking water quality.
Rice, E W; Geldreich, E E; Read, E J
1989-01-01
The concern for improved monitoring of the sanitary quality of drinking water has prompted interest in alternative methods for the detection of total coliform bacteria. A simplified qualitative presence-absence test has been proposed as an alternate procedure for detecting coliform bacteria in potable water. In this paper data from four comparative studies were analyzed to compare the recovery of total coliform bacteria from drinking water using the presence-absence test, the multiple fermentation tube procedure, and the membrane filter technique. The four studies were of water samples taken from four different geographic areas of the United States: Hawaii, New England (Vermont and New Hampshire), Oregon, and Pennsylvania. Analysis of the results of these studies were compared, based upon the number of positive samples detected by each method. Combined recoveries showed the presence-absence test detected significantly higher numbers of samples with coliforms than either the fermentation tube or membrane filter methods, P less than 0.01. The fermentation tube procedure detected significantly more positive samples than the membrane filter technique, P less than 0.01. Based upon the analysis of the combined data base, it is clear that the presence-absence test is as sensitive as the current coliform methods for the examination of potable water. The presence-absence test offers a viable alternative to water utility companies that elect to use the frequency-of-occurrence approach for compliance monitoring. PMID:2493663
Butler, Chris C; Dunstan, Frank; Heginbothom, Margaret; Mason, Brendan; Roberts, Zoë; Hillier, Sharon; Howe, Robin; Palmer, Stephen; Howard, Anthony
2007-01-01
Background GPs are urged to prescribe antibiotics less frequently, despite lack of evidence linking reduced antibiotic prescribing with reductions in resistance at a local level. Aim To investigate associations between changes in antibiotic dispensing and changes in antibiotic resistance at general-practice level. Design of study Seven-year study of dispensed antibiotics and antibiotic resistance in coliform isolates from urine samples routinely submitted from general practice. Setting General practices in Wales. Method Multilevel modelling of trends in resistance to ampicillin and trimethoprim, and changes in practice total antibiotic dispensing and amoxicillin and trimethoprim dispensing. Results The primary analysis included data on 164 225 coliform isolates from urine samples submitted from 240 general practices over the 7-year study period. These practices served a population of 1.7 million patients. The quartile of practices that had the greatest decrease in total antibiotic dispensing demonstrated a 5.2% reduction in ampicillin resistance over the 7-year period with changes of 0.4%, 2.4%, and −0.3% in the other three quartiles. There was a statistically significant overall decrease in ampicillin resistance of 1.03% (95% confidence interval [CI] = 0.37 to 1.67%) per decrease of 50 amoxicillin items dispensed per 1000 patients per annum. There were also significant reductions in trimethoprim resistance in the two quartiles of practices that reduced total antibiotic dispensing most compared with those that reduced it least, with an overall decrease in trimethoprim resistance of 1.08% (95% CI = 0.065 to 2.10%) per decrease of 20 trimethoprim items dispensed per 1000 patients per annum. Main findings were confirmed by secondary analyses of 256 370 isolates from 527 practices that contributed data at some point during the study period. Conclusion Reducing antibiotic dispensing at general-practice level is associated with reduced local antibiotic resistance. These findings should further encourage clinicians and patients to use antibiotics conservatively. PMID:17925135
APPARENT BIAS IN RIVER WATER INOCULUM FOLLOWING CENTRIFUGATION
We collected four measures of viable bacterial concentration (heterotrophic plate count, total coliform, fecal coliform, and Escherichia coli) and three measures of well color development in Biolog GN2 microtiter plates from water samples that were collected on two or three separ...
40 CFR 432.75 - New source performance standards (NSPS).
Code of Federal Regulations, 2011 CFR
2011-07-01
... achieve the standards for BOD5, fecal coliform, O&G, and TSS specified in § 432.72(a). (b) Facilities that..., fecal coliform, O&G, and TSS specified in § 432.72(b) and the limitations for ammonia (as N) and total...
40 CFR 432.95 - New source performance standards (NSPS).
Code of Federal Regulations, 2011 CFR
2011-07-01
... standards for BOD 5, fecal coliform, O&G, and TSS specified in § 432.92(a). (b) Facilities that generate... coliform, O&G, and TSS specified in § 432.92(b) and the limitations for ammonia (as N) and total nitrogen...
Hua, Ang Kean
2017-01-01
Malacca River water quality is affected due to rapid urbanization development. The present study applied LULC changes towards water quality detection in Malacca River. The method uses LULC, PCA, CCA, HCA, NHCA, and ANOVA. PCA confirmed DS, EC, salinity, turbidity, TSS, DO, BOD, COD, As, Hg, Zn, Fe, E. coli , and total coliform. CCA confirmed 14 variables into two variates; first variate involves residential and industrial activities; and second variate involves agriculture, sewage treatment plant, and animal husbandry. HCA and NHCA emphasize that cluster 1 occurs in urban area with Hg, Fe, total coliform, and DO pollution; cluster 3 occurs in suburban area with salinity, EC, and DS; and cluster 2 occurs in rural area with salinity and EC. ANOVA between LULC and water quality data indicates that built-up area significantly polluted the water quality through E. coli , total coliform, EC, BOD, COD, TSS, Hg, Zn, and Fe, while agriculture activities cause EC, TSS, salinity, E. coli , total coliform, arsenic, and iron pollution; and open space causes contamination of turbidity, salinity, EC, and TSS. Research finding provided useful information in identifying pollution sources and understanding LULC with river water quality as references to policy maker for proper management of Land Use area.
Grabow, W O; du Preez, M
1979-01-01
Total coliform counts obtained by means of standard membrane filtration techniques, using MacConkey agar, m-Endo LES agar, Teepol agar, and pads saturated with Teepol broth as growth media, were compared. Various combinations of these media were used in tests on 490 samples of river water and city wastewater after different stages of conventional purification and reclamation processes including lime treatment, and filtration, active carbon treatment, ozonation, and chlorination. Endo agar yielded the highest average counts for all these samples. Teepol agar generally had higher counts then Teepol broth, whereas MacConkey agar had the lowest average counts. Identification of 871 positive isolates showed that Aeromonas hydrophila was the species most commonly detected. Species of Escherichia, Citrobacter, Klebsiella, and Enterobacter represented 55% of isolates which conformed to the definition of total coliforms on Endo agar, 54% on Teepol agar, and 45% on MacConkey agar. Selection for species on the media differed considerably. Evaluation of these data and literature on alternative tests, including most probable number methods, indicated that the technique of choice for routine analysis of total coliform bacteria in drinking water is membrane filtration using m-Endo LES agar as growth medium without enrichment procedures or a cytochrome oxidase restriction. PMID:394678
Lisle, J.T.; Smith, J.J.; Edwards, D.D.; McFeters, G.A.
2004-01-01
McMurdo Station, Antarctica, has discharged untreated sewage into McMurdo Sound for decades. Previous studies delineated the impacted area, which included the drinking water intake, by using total coliform and Clostridium perfringens concentrations. The estimation of risk to humans in contact with the impacted and potable waters may be greater than presumed, as these microbial indicators may not be the most appropriate for this environment. To address these concerns, concentrations of these and additional indicators (fecal coliforms, Escherichia coli, enterococci, coliphage, and enteroviruses) in the untreated wastewater, water column, and sediments of the impacted area and drinking water treatment facility and distribution system at McMurdo Station were determined. Fecal samples from Weddell seals in this area were also collected and analyzed for indicators. All drinking water samples were negative for indicators except for a single total coliform-positive sample. Total coliforms were present in water column samples at higher concentrations than other indicators. Fecal coliform and enterococcus concentrations were similar to each other and greater than those of other indicators in sediment samples closer to the discharge site. C. perfringens concentrations were higher in sediments at greater distances from the discharge site. Seal fecal samples contained concentrations of fecal coliforms, E. coli, enterococci, and C. perfringens similar to those found in untreated sewage. All samples were negative for enteroviruses. A wastewater treatment facility at McMurdo Station has started operation, and these data provide a baseline data set for monitoring the recovery of the impacted area. The contribution of seal feces to indicator concentrations in this area should be considered.
Tiyo, Rogerio; de Souza, Carla Zangari; Nishi, Letícia; Brustolin, Camila Fernanda; Ratti, Bianca Altrão; Falavigna Guilherme, Ana Lucia
2015-01-01
The aim of this work was to compare, from a parasitological ( Cryptosporidium spp. and Giardia duodenalis), bacteriological (total and thermotolerants coliforms) and physicochemical perspective, water sources used for drinking and irrigation of vegetables intended to be sold for human consumption. From January 2010 to May 2011, samples of different water sources from vegetable producing properties were collected; 100 liters for parasitological analysis, 200 mL for bacteriological analysis, and five liters for physicochemical analysis. Water samples were filtered under vacuum with a kit containing a cellulose acetate membrane filter, 1.2 µm (Millipore(r), Barueri, SP, Brazil). The material retained on the membrane was mechanically extracted and analyzed by direct immunofluorescence (Merifluor(r)kit). From 20 rural properties investigated, 10 had artesian wells (40 samples), 10 had common wells (40 samples), and one had a mine (four samples), the latter contaminated by Cryptosporidium spp. In samples from artesian wells, 90 to 130 meters depth, 42.5% were positive for total coliforms and 5.0% were identified to have abnormal coloration. From the samples of common wells, 14 to 37 meters depth, 87.5% were contaminated with total coliforms, 82.5% were positive for thermotolerant coliforms, and 12.5% had color abnormalities. We did not detect the presence of Giardia spp. or Cryptosporidium spp. in artesian and common wells. The use of artesian or common wells is an important step in the control of the spreading of zoonoses, particularly Cryptosporidium spp. and Giardia spp., as well as artesian wells for coliform control in local production of vegetables to be marketed.
TIYO, Rogerio; de SOUZA, Carla Zangari; NISHI, Letícia; BRUSTOLIN, Camila Fernanda; RATTI, Bianca Altrão; FALAVIGNA GUILHERME, Ana Lucia
2015-01-01
SUMMARY The aim of this work was to compare, from a parasitological ( Cryptosporidiumspp. and Giardia duodenalis), bacteriological (total and thermotolerants coliforms) and physicochemical perspective, water sources used for drinking and irrigation of vegetables intended to be sold for human consumption. From January 2010 to May 2011, samples of different water sources from vegetable producing properties were collected; 100 liters for parasitological analysis, 200 mL for bacteriological analysis, and five liters for physicochemical analysis. Water samples were filtered under vacuum with a kit containing a cellulose acetate membrane filter, 1.2 µm (Millipore(r), Barueri, SP, Brazil). The material retained on the membrane was mechanically extracted and analyzed by direct immunofluorescence (Merifluor(r)kit). From 20 rural properties investigated, 10 had artesian wells (40 samples), 10 had common wells (40 samples), and one had a mine (four samples), the latter contaminated by Cryptosporidiumspp. In samples from artesian wells, 90 to 130 meters depth, 42.5% were positive for total coliforms and 5.0% were identified to have abnormal coloration. From the samples of common wells, 14 to 37 meters depth, 87.5% were contaminated with total coliforms, 82.5% were positive for thermotolerant coliforms, and 12.5% had color abnormalities. We did not detect the presence of Giardiaspp. or Cryptosporidiumspp. in artesian and common wells. The use of artesian or common wells is an important step in the control of the spreading of zoonoses, particularly Cryptosporidiumspp. and Giardiaspp., as well as artesian wells for coliform control in local production of vegetables to be marketed. PMID:26422158
Assessing the sources of high fecal coliform levels at an urban tropical beach
Davino, Aline Mendonça Cavalcante; de Melo, Milena Bandeira; Caffaro, Roberto Augusto
2015-01-01
Recreational water quality is commonly assessed by microbial indicators such as fecal coliforms. Maceió is the capital of Alagoas state, located in tropical northeastern Brazil. Its beaches are considered as the most beautiful urban beaches in the country. Jatiúca Beach in Maceió was found to be unsuitable for bathing continuously during the year of 2011. The same level of contamination was not observed in surrounding beaches. The aim of this study was to initiate the search for the sources of these high coliform levels, so that contamination can be eventually mitigated. We performed a retrospective analysis of historical results of fecal coliform concentrations from 2006 to 2012 at five monitoring stations located in the study region. Results showed that Jatiúca Beach consistently presented the worst quality among the studied beaches. A field survey was conducted to identify existing point and non-point sources of pollution in the area. Monitoring in the vicinity of Jatiúca was spatially intensified. Fecal coliform concentrations were categorized according to tide range and tide stage. A storm drain located in northern Jatiúca was identified as the main point source of the contamination. However, fecal coliform concentrations at Jatiúca were high during high tides and spring tides even when this point source was inactive (no rainfall). We hypothesize that high fecal coliform levels in Jatiúca Beach may also be caused by aquifer contamination or, more likely, from tide washing of contaminated sand. Both of these hypotheses will be further investigated. PMID:26691459
Assessing the sources of high fecal coliform levels at an urban tropical beach.
Davino, Aline Mendonça Cavalcante; de Melo, Milena Bandeira; Caffaro Filho, Roberto Augusto
2015-01-01
Recreational water quality is commonly assessed by microbial indicators such as fecal coliforms. Maceió is the capital of Alagoas state, located in tropical northeastern Brazil. Its beaches are considered as the most beautiful urban beaches in the country. Jatiúca Beach in Maceió was found to be unsuitable for bathing continuously during the year of 2011. The same level of contamination was not observed in surrounding beaches. The aim of this study was to initiate the search for the sources of these high coliform levels, so that contamination can be eventually mitigated. We performed a retrospective analysis of historical results of fecal coliform concentrations from 2006 to 2012 at five monitoring stations located in the study region. Results showed that Jatiúca Beach consistently presented the worst quality among the studied beaches. A field survey was conducted to identify existing point and non-point sources of pollution in the area. Monitoring in the vicinity of Jatiúca was spatially intensified. Fecal coliform concentrations were categorized according to tide range and tide stage. A storm drain located in northern Jatiúca was identified as the main point source of the contamination. However, fecal coliform concentrations at Jatiúca were high during high tides and spring tides even when this point source was inactive (no rainfall). We hypothesize that high fecal coliform levels in Jatiúca Beach may also be caused by aquifer contamination or, more likely, from tide washing of contaminated sand. Both of these hypotheses will be further investigated.
Haushild, W.L.; Prych, Edmund A.
1976-01-01
Total- and fecal-coliform bacteria, plus pH, alkalinity, and dissolved inorganic carbon are water-quality parameters that have been added to an existing numerical model of water quality in the salt-wedge reach of the Duwamish River estuary in Washington. The coliform bacteria are modeled using a first-order decay (death) rate, which is a function of the local salinity, temperature, and daily solar radiation. The pH is computed by solving a set of chemical-equilibrium equations for carbonate-bicarbonate buffered aqueous solutions. Concentrations of total- and fecal-coliform bacteria computed by the model for the Duwamish River estuary during June-September 1971 generally agreed with observed concentrations within about 40 and 60 percent, respectively. The computed pH generally agreed with observed pH within about a 0.2 pH unit; however, for one 3-week period the computed pH was about a 0.4 unit lower than the observed pH. (Woodard-USGS)
Chattman, Marisa; Gerba, Sheri L; Maxwell, Charles P
2011-03-01
The goal of the study discussed in this article was to determine the occurrence of heterotrophic and coliform bacteria in liquid soap from bulk refillable dispensers, obtained from restrooms in a variety of public facilities. A total of 541 samples was collected from five U.S. cities. Liquid soap from dispensers in public areas was found to contain heterotrophic and coliform bacterial numbers averaging more than 106 CFU/mL in 24.8% of the dispensers.
Ortega, Cristina; Solo-Gabriele, Helena M.; Abdelzaher, Amir; Wright, Mary; Deng, Yang; Stark, Lillian M.
2009-01-01
The objective of this study was to evaluate whether indicator microbes and physical-chemical parameters were correlated with pathogens within a tidally influenced estuary. Measurements included the analysis of physical-chemical parameters (pH, salinity, temperature, and turbidity), measurements of bacterial indicators (enterococci, fecal coliform, E. coli, and total coliform), viral indicators (somatic and MS2 coliphage), viral pathogens (enterovirus by culture), and protozoan pathogens (Cryptosporidium and Giardia). All pathogen results were negative with the exception of one sample which tested positive for culturable reovirus (8.5 MPN/100 L).. Notable physical-chemical parameters for this sample included low salinity (<1 ppt) and high water temperature (31 °C). Indicator bacteria and indicator virus levels for this sample were within average values typically measured within the study site and were low in comparison with levels observed in other freshwater environments. Overall results suggest that high levels of bacterial and viral indicators were associated with low salinity sites. PMID:19464704
Gill, C O; Bryant, J; Badoni, M
2001-02-15
Ten 12-kg lots of manufacturing beef from a single packing plant were obtained from a hamburger patty manufacturing plant. Each lot was divided into two, 6-kg portions, one of which was not treated while the other was treated with water of 85 degrees C. A portion from one lot was treated for 15 s. A portion from each of three lots was treated for 30 s, three portions were treated for 45 s, and three were treated for 60 s. Twenty-five pieces of meat from each portion were swabbed over areas of 100 cm2. Subsequently, each portion was first coarsely ground then finely ground, with twenty-five 100-g samples being taken from each portion at each stage of grinding. Each swab and sample of ground meat was separately processed for the enumeration of total aerobic counts, coliforms and Escherichia coli at levels of detection of 1 cfu/cm2, 1 cfu/100 cm2 and 1 cfu/100 cm2, respectively, for swab samples; and at a level of detection of 1 cfu/g for all three types of bacteria in samples of ground beef. A 250-kg batch of manufacturing beef was treated with water of 85 degrees C for 60 s. The product was processed through commercial equipment for manufacturing frozen hamburger patties. The flavour of patties prepared from the pasteurized product was compared with the flavour of patties prepared during normal commercial operation of the equipment. The weight of the manufacturing beef was not affected by the treatments. Similar total numbers of coliforms or E. coli were recovered per 2500 cm2 from the 25 swab samples or per 25 g from the 25 ground beef samples from each untreated portion. As the ratio of the surface area in cm2 to the weight in g would likely be < or = 1, the similar numbers indicated that swab sampling was inefficient for recovering coliforms and E. coli from the meat. However, coliforms and E. coli were recovered more frequently from swab than from ground beef samples from treated portions. Thus, some swabs from all three portions of beef treated for 30 s yielded coliforms and E. coli, but samples from portions treated for 45 or 60 s yielded few coliforms and no E. coli. The numbers recovered from the treated and untreated portions indicated that treatments for 45 or 60 s reduced both coliform and E. coli numbers by two orders of magnitude. The flavours of cooked patties prepared from the meat pasteurized with water of 85 degrees C for 60 s were not distinguished from the normal commercial product. The data indicate that pasteurizing manufacturing beef with water of 85 degrees C for 45 s could be a practicable treatment for enhancing the microbiological safety of frozen hamburger patties.
Wahba, Nahed M; Ahmed, Amany S; Ebraheim, Zedan Z
2010-04-01
This study was designed to assess the application of some edible plants including cayenne, green pepper, parsley, and dill to Kareish cheese and to evaluate the antimicrobial activity of these plant materials against natural microflora, coliforms, molds, and Staphylococcus aureus. Twelve different concentrations of ethanol extract of the plants were prepared for determination of the minimal inhibitory concentration. Cayenne and green pepper extracts showed highest activity followed by dill and parsley against S. aureus. Addition of cayenne or green pepper to Kareish cheese during manufacture revealed that both plants were able reduce the S. aureus population to undetectable level within the first and second days of storage. To study the effect of combining plant materials on the microbiological quality of ready-to-eat Kareish cheese, the total bacterial count, coliform count, and yeast and molds counts were determined. It has been found that addition of plant materials to Kareish cheese reduced the total bacterial and coliform populations. All concentrations of cayenne, green pepper, dill, and parsley (9%) completely reduced the yeast count within 2 hours. Cayenne and green pepper completely reduced the mold count within 2 days, whereas parsley and dill were found to be less effective. Kareish cheese prepared with 1% cayenne pepper and 3% and 6% each of green pepper, dill, and parsley were found strongly acceptable to the consumer and considered the most preferable type. Therefore, this study revealed that pepper, parsley, and dill exhibited antibacterial activity against natural microflora, coliforms, yeast and molds, and S. aureus in Kareish cheese, and the addition of these plants is acceptable to the consumer and may contribute to the development of new and safe varieties of Kareish cheese.
Yeung-Cheung, Anna K; Melendez, Nadilynn J
2007-02-01
Harbor Island Park of Mamaroneck Harbor is one of the beaches that has been frequently closed to the public due to unsanitary swimming conditions. In 2002, a Gunderboom BPS (Beach Protection System) was reinstalled in Harbor Island Park to lower bacterial levels in swimming areas. The first Gunderboom had been destroyed by an oil spill several years before. The current Gunderboom is an 800 foot curtain made of a treated polypropylene/polyester fabric and the company claims a 99.1% coliform reduction with its use. In this study, water inside and outside the Gunderboom was tested weekly from June to August 2005, and bi-weekly from September to December 2005. Coliscan Membrane Filtration plates were used to recover the relative amounts of Escherichia coli and coliform bacteria from the water. Soft-shelled clams (Mya arenaria) living in both these areas were also tested for their E. coli and coliform bacteria level using 3M Petrifilm plates. Water was also tested from Hudson Park in New Rochelle, a frequently closed beach due to high levels of coliform bacteria, as well as from Read Sanctuary in Rye, a "pristine" beach. Our results showed the amount of E. coli and coliform bacteria recovered from the water inside the Gunderboom were significantly lower (P < 0.05) compared to outside the Gunderboom and Hudson Park. There was 81.9% reduction in E. coli and 51.6% reduction in coliform bacteria inside the Gunderboom as compared to the outside. In addition, significant differences (P < 0.05) were found with lower numbers of E. coli and coliform bacteria recovered from the clams inside the Gunderboom compared to outside the Gunderboom. In conclusion, the Gunderboom system installed in Mamaroneck Harbor resulted in a significant reduction of E. coli and coliform bacteria in the water and clam samples, thus proving its efficiency as a water filter.
Irrigation waters and pipe-based biofilms as sources for antibiotic-resistant bacteria.
Blaustein, Ryan A; Shelton, Daniel R; Van Kessel, Jo Ann S; Karns, Jeffrey S; Stocker, Matthew D; Pachepsky, Yakov A
2016-01-01
The presence of antibiotic-resistant bacteria in environmental surface waters has gained recent attention. Wastewater and drinking water distribution systems are known to disseminate antibiotic-resistant bacteria, with the biofilms that form on the inner-surfaces of the pipeline as a hot spot for proliferation and gene exchange. Pipe-based irrigation systems that utilize surface waters may contribute to the dissemination of antibiotic-resistant bacteria in a similar manner. We conducted irrigation events at a perennial stream on a weekly basis for 1 month, and the concentrations of total heterotrophic bacteria, total coliforms, and fecal coliforms, as well as the concentrations of these bacterial groups that were resistant to ampicillin and tetracycline, were monitored at the intake water. Prior to each of the latter three events, residual pipe water was sampled and 6-in. sections of pipeline (coupons) were detached from the system, and biofilm from the inner-wall was removed and analyzed for total protein content and the above bacteria. Isolates of biofilm-associated bacteria were screened for resistance to a panel of seven antibiotics, representing five antibiotic classes. All of the monitored bacteria grew substantially in the residual water between irrigation events, and the biomass of the biofilm steadily increased from week to week. The percentages of biofilm-associated isolates that were resistant to antibiotics on the panel sometimes increased between events. Multiple-drug resistance was observed for all bacterial groups, most often for fecal coliforms, and the distributions of the numbers of antibiotics that the total coliforms and fecal coliforms were resistant to were subject to change from week to week. Results from this study highlight irrigation waters as a potential source for antibiotic-resistant bacteria, which can subsequently become incorporated into and proliferate within irrigation pipe-based biofilms.
40 CFR 141.21 - Coliform sampling.
Code of Federal Regulations, 2011 CFR
2011-07-01
... transit. 3 Lactose broth, as commercially available, may be used in lieu of lauryl tryptose broth, if the... total coliform, using lactose broth, is less than 10 percent. 4 If inverted tubes are used to detect gas... negative-rates may be based on lactose fermentation, the rapid test for β-galactosidase and cytochrome...
40 CFR 141.21 - Coliform sampling.
Code of Federal Regulations, 2010 CFR
2010-07-01
... transit. 3 Lactose broth, as commercially available, may be used in lieu of lauryl tryptose broth, if the... total coliform, using lactose broth, is less than 10 percent. 4 If inverted tubes are used to detect gas... negative-rates may be based on lactose fermentation, the rapid test for β-galactosidase and cytochrome...
Biadglegne, Fantahun; Tessema, Belay; Kibret, Mulugeta; Abera, Bayeh; Huruy, Kahsay; Anagaw, Belay; Mulu, Andargachew
2009-10-01
The consumption of bottled drinking water is becoming increasing in Ethiopia. As a result there has been a growing concern about the chemical, physical and bacteriological quality of this product. Studies on the chemical, physical and bacteriological quality of bottled water is quite scarce in Ethiopia. This study was therefore aimed to assess the physicochemical and bacteriological qualities of three factories of bottled drinking water products produced in Amhara region. A Laboratory based comparative study was conducted to evaluate the physicochemical and bacteriological quality of three factories of bottled drinking water produced in Amhara region. Analysis on the quality of bottled drinking water from the sources, wholesalers and retailers were made with World Health Organization and Quality and Standards Authority of Ethiopia recommendations. Triplicate samples from three types of bottled drinking water were randomly collected and analyzed from June, 2006 to December, 2006. A total of 108 commercial bottled drinking water samples were analyzed. The result showed that except pH of factory A all the physicochemical parameters analyzed were with in the recommended limits. The pH value of factory A tested from sources is 5.3 and from wholesalers and retailers is 5.5 and 5.3, respectively, which is below the normal value set by World Health Organization (6.5-8.0) and Quality and Standards Authority of Ethiopia (6.0-8.5). Our analyses also demonstrated that 2 (16.7%) of the samples tested from sources and 1 (8.3%) from wholesalers of factory B were contaminated with total coliforms, where as 2 (16.7%) samples from retailers were also contaminated with total coliforms. On the other hand, 1 (8.3%) of the samples tested from wholesalers and 2 (16.7%) of the samples tested from retailers of factory A were also contaminated with total coliforms. Total coliforms were not detected from all samples of factory C, fecal coliforms were not also isolated from all samples. Percent of coefficient of variation showed that variations in total coliforms counts were significant with in the samples of both factory A and B (CV > 10%). Based on the recommended limit of World Health Organization and Quality and Standards Authority of Ethiopia, 7.4% of bottled drinking water sold commercially could be considered unfit for human consumption. Consumers of bottled water should be aware of this.
Rizzo, Luigi
2009-06-15
In this study the potential application of TiO(2) photocatalysis as primary disinfection system of drinking water was investigated in terms of coliform bacteria inactivation and injury. As model water the effluent of biological denitrification unit for nitrate removal from groundwater, which is characterized by high organic matter and bacteria release, was used. The injury of photocatalysis on coliform bacteria was characterized by means of selective (mEndo) and less selective (mT7) culture media. Different catalyst loadings as well as photolysis and adsorption effects were investigated. Photocatalysis was effective in coliform bacteria inactivation (91-99% after 60 min irradiation time, depending on both catalyst loading and initial density of coliform bacteria detected by mEndo), although no total removal was observed after 60 min irradiation time. The contribution of adsorption mechanism was significant (60-98% after 60 min, depending on catalyst loading) compared to previous investigations probably due to the nature of source water rich in particulate organic matter and biofilm. Photocatalysis process did not result in any irreversible injury (98.8% being the higher injury) under investigated conditions, thus a bacteria regrowth may take place under optimum environment conditions if any final disinfection process (e.g., chlorine or chlorine dioxide) is not used.
Rakhmanin, Yu A; Ivanova, L V; Artemova, T Z; Gipp, E K; Zagaynova, A V; Maksimkina, T N; Krasnyak, A V; Zhuravlev, P V; Aleshnya, V V; Panasovets, O P
2016-01-01
The used methodology of the scientific substantiation of indicators is in the establishment of the conformity of laws of vital activity of indicator and pathogenic microorganisms in the real conditions of the action of the complex of factors, including disinfecting agents. In the one water sample simultaneously there were determined both the general indicator (GICB), thermotolerant (TTCB), glucose positive (GPCB) coliform bacteria, E.coli. On the base of long-term research in the various regions of the Russian Federation, as well with bearing in mind the analysis of domestic and foreign data, comparing the water quality and the incidence of intestinal infections in population it is recommended to use the index of determination of the total number glucose positive coliform bacteria (GPCB), which brings together a much broader range of bacteria of the Enterobacteriaceae family in comparison with total coliform bacteria (TCB) and thermotolerant coliform bacteria (TTCB) and warrants the absence in the test volume of water as an indicator lactose positive (E.coli, TCB, TTCB) and pathogens (salmonella) and potentially pathogenic bacteria which do not ferment lactose. Proposed index of GPCB is shown to allow to assess epidemiological risks not only more accurate, but also more efficiently without increasing the cost performance of bacteriological research.
Survival and detection of coliforms, Enterobacteriaceae, and gram-negative bacteria in Greek yogurt.
Hervert, C J; Martin, N H; Boor, K J; Wiedmann, M
2017-02-01
Despite the widespread use of coliforms as indicator bacteria, increasing evidence suggests that the Enterobacteriaceae (EB) and total gram-negative groups more accurately reflect the hygienic status of high-temperature, short-time pasteurized milk and processing environments. If introduced into milk as postpasteurization contamination, these bacteria may grow to high levels and produce a wide range of sensory-related defects. However, limited information is available on the use and survival of bacterial hygiene indicators in dairy products outside of pasteurized fluid milk and cheese. The goal of this study was to (1) provide information on the survival of a diverse set of bacterial hygiene indicators in the low pH environment of Greek yogurt, (2) compare traditional and alternative detection methods for their ability to detect bacterial hygiene indicators in Greek yogurt, and (3) offer insight into optimal hygiene indicator groups for use in low-pH fermented dairy products. To this end, we screened 64 bacterial isolates, representing 24 dairy-relevant genera, for survival and detection in Greek yogurt using 5 testing methods. Before testing, isolates were inoculated into plain, 0% fat Greek yogurt (pH 4.35 to 4.65), followed by a 12-h hold period at 4 ± 1°C. Yogurts were subsequently tested using Coliform Petrifilm (3M, St. Paul, MN) to detect coliforms; Enterobacteriaceae Petrifilm (3M), violet red bile glucose agar and the D-Count (bioMérieux, Marcy-l'Étoile, France) to detect EB; and crystal violet tetrazolium agar (CVTA) to detect total gram-negative bacteria. Overall, the non-EB gram-negative isolates showed significantly larger log reductions 12 h after inoculation into Greek yogurt (based on bacterial numbers recovered on CVTA) compared with the coliform and noncoliform EB isolates tested. The methods evaluated varied in their ability to detect different microbial hygiene indicators in Greek yogurt. Crystal violet tetrazolium agar detected the highest portion of coliforms, whereas EB Petrifilm detected the highest portion of EB, as well as highest portion of total gram-negative bacteria. Additionally, the D-Count method allowed for faster detection of EB in yogurt by generating results in approximately 13 h rather than the 24 h required when using EB Petrifilm and violet red bile glucose agar. Results from this study indicate that the coliform and EB groups encompass a broad range of dairy-relevant gram-negative bacteria with the ability to survive in Greek yogurt, supporting their use as microbial hygiene indicator groups in low-pH fermented dairy products. The Authors. Published by the Federation of Animal Science Societies and Elsevier Inc. on behalf of the American Dairy Science Association®. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
Quality evaluation of processed clay soil samples.
Steiner-Asiedu, Matilda; Harrison, Obed Akwaa; Vuvor, Frederick; Tano-Debrah, Kwaku
2016-01-01
This study assessed the microbial quality of clay samples sold on two of the major Ghanaian markets. The study was a cross-sectional assessing the evaluation of processed clay and effects it has on the nutrition of the consumers in the political capital town of Ghana. The items for the examination was processed clay soil samples. Staphylococcus spp and fecal coliforms including Klebsiella, Escherichia, and Shigella and Enterobacterspp were isolated from the clay samples. Samples from the Kaneshie market in Accra recorded the highest total viable counts 6.5 Log cfu/g and Staphylococcal count 5.8 Log cfu/g. For fecal coliforms, Madina market samples had the highest count 6.5 Log cfu/g and also recorded the highest levels of yeast and mould. For Koforidua, total viable count was highest in the samples from the Zongo market 6.3 Log cfu/g. Central market samples had the highest count of fecal coliforms 4.6 Log cfu/g and yeasts and moulds 6.5 Log cfu/g. "Small" market recorded the highest staphylococcal count 6.2 Log cfu/g. The water activity of the clay samples were low, and ranged between 0.65±0.01 and 0.66±0.00 for samples collected from Koforidua and Accra respectively. The clay samples were found to contain Klebsiella spp. Escherichia, Enterobacter, Shigella spp. staphylococcus spp., yeast and mould. These have health implications when consumed.
Analysis of chemical contamination within a canal in a Mexican border colonia.
Owens, Janel E; Niemeyer, Emily D
2006-04-01
This study examines urban pollution within Derechos Humanos, a colonia popular in Matamoros, Tamaulipas, Mexico. General water quality indicators (coliform bacteria, total dissolved solids, ecologically relevant cations and anions), heavy metals (copper, lead, nickel, zinc, iron and cadmium), and volatile organic compounds (benzene, toluene, ethylbenzene, styrene, and dichlorobenzene and xylene isomers) were quantified within a wastewater canal running adjacent to the community. Water samples were collected at multiple sites along the banks of the canal and evidence of anthropogenic emissions existed at each sampling location. Sample site 2, approximately 10 m upstream of the colonia, contained both the widest range of hazardous pollutants and the greatest number exceeding US Environmental Protection Agency surface water standards. At each sampling location, high concentrations of total coliform (> 10(4) colonies/100 mL sample), lead (ranging from 0.05 to 0.40 mg/L), nickel (levels from 0.21 to 1.45 mg/L), and benzene (up to 9.80 mg/L) were noted.
Coliform Bacteria Monitoring in Fish Systems: Current Practices in Public Aquaria.
Culpepper, Erin E; Clayton, Leigh A; Hadfield, Catherine A; Arnold, Jill E; Bourbon, Holly M
2016-06-01
Public aquaria evaluate coliform indicator bacteria levels in fish systems, but the purpose of testing, testing methods, and management responses are not standardized, unlike with the coliform bacteria testing for marine mammal enclosures required by the U.S. Department of Agriculture. An online survey was sent to selected aquaria to document current testing and management practices in fish systems without marine mammals. The information collected included indicator bacteria species, the size and type of systems monitored, the primary purpose of testing, sampling frequency, test methods, the criteria for interpreting results, corrective actions, and management changes to limit human exposure. Of the 25 institutions to which surveys were sent, 19 (76%) responded. Fourteen reported testing for fecal indicator bacteria in fish systems. The most commonly tested indicator species were total (86%) and fecal (79%) coliform bacteria, which were detected by means of the membrane filtration method (64%). Multiple types and sizes of systems were tested, and the guidelines for testing and corrective actions were highly variable. Only three institutions performed additional tests to confirm the identification of indicator organisms. The results from this study can be used to compare bacterial monitoring practices and protocols in fish systems, as an aid to discussions relating to the accuracy and reliability of test results, and to help implement appropriate management responses. Received August 23, 2015; accepted December 29, 2015.
Wang, Dunling; Fiessel, Wanda
2008-01-01
This study evaluated three different dehydrated media for simultaneous detection and enumeration of total coliform (TC) and Escherichia coli in drinking water samples with a standard membrane filtration procedure. The experiment indicated that the differential coliform agar (DCA) medium was the most effective among the tested media in enumerating TC and E. coli, without the need for extensive accompanying confirmation tests. The results for DCA medium were highly reproducible for both TC and E. coli with standard deviation of 6.0 and 6.1, respectively. A high agreement (82%) was found between DCA and m-Endo media on 152 drinking water samples in terms of TC positive. The DCA medium also reduced concealment of background bacteria.
Gibson, Sarah; Sahanggamu, Daniel; Fatmaningrum, Dewi; Curtis, Val; White, Sian
2017-10-01
To examine levels of bacterial contamination in formula feeding bottles in Sidoarjo, East Java, and to assess the preparation practices that may have been responsible. A cross-sectional study was conducted among 92 randomly selected households with children under the age of two who were bottle-fed formula. In each household, we carried out video observation of mothers/caregivers preparing bottles, and examined samples of formula for coliform bacteria and Escherichia coli (E. coli). In-depth interviews were conducted with a subsample of 20 mothers. A total of 88% of the formula feeds were contaminated with total coliforms at a level >10 MPN/ml, and 45% contained E. coli. These feeds were defined as 'unfit for human consumption'. In the video observations, none of the mothers complied with all five WHO-recommended measures of hygienic formula feed preparation. Only two mothers washed their hands with soap prior to formula preparation. Most mothers also failed to clean or sterilise the bottle and clean the preparation area. In-depth interviews confirmed that such suboptimal hygiene practices were common. The high levels of contamination found highlight that bottles are an important faecal-oral exposure pathway resulting from poor hygiene practices during bottle preparation. © 2017 John Wiley & Sons Ltd.
Myers, Donna N.
1992-01-01
This report presents the results of a study by the U.S. Geological Survey, in cooperation with the City of Columbus, Ohio, to determine the distribution and variability of fecal-indicator bacteria in Scioto and Olentangy Rivers. Fecal-indicator bacteria are among the contaminants of concern to recreational users of these rivers in the Columbus area. Samples were collected to be analyzed for fecal-coliform and Escherichia coli (E. coli) bacteria and selected water-quality constituents and physical properties at 10 sites-- 4 on the Olentangy River and 6 on the Scioto River during the recreational seasons in 1987, 1988, and 1989. Measurements of streamflow also were made at these sites at various frequencies during base flow and runoff. The concentrations of fecal-coliform and E. coli bacteria in the Scioto and Olentangy Rivers spanned a range of five orders of magnitude, from less than 20 to greater than 2,000,000 col/100 mL (colonies per 100 milliliters). In addition, the concentrations of fecal coliform and E. coli bacteria are well correlated (r=0.97) in the study area. At times, relatively high concentrations, for fecal-indicator bacteria (concentrations greater than 51,000 col/100 mL for fecal-coliform and E. coli ) were found in Olentangy River at Woody Hayes Drive and at Goodale Street, and in Scioto River at Greenlawn Avenue and at Columbus. Intermediate concentrations of fecal-indicator bacteria (from 5,100 to 50,000 col/100 mL for fecal coliform and (from 510 to 50,000 col/100 mL for E. coli ) were found in Scioto River at Town Street and below O'Shaughnessy Dam near Dublin, Ohio, and in Olentangy River at Henderson Road. The lowest (median) concentrations of fecal-indicator bacteria (from 20 to 5,000 col/100 mL for fecal coliform and from 20 to 500 col/100 mL for E. coli ) were found at Olentangy River near Worthington, Ohio, Scioto River at Dublin Road Water Treatment Plant and below Griggs Reservoir. Fecal-coliform concentrations exceeded the geometric mean and single-sample Ohio Water Quality Standards for recreation less frequently than E. coli concentrations. The E. coli numerical water-quality standards are more difficult to meet than the fecal coliform standards because they are as much as an order of magnitude lower in some instances. The geometric mean bathing-water and primary-contact standards for fecal-coliform and E. coli bacteria were exceeded in more samples for Olentangy River at Goodale Street than for any other site. The single-sample bathing-water standard for fecal-coliform bacteria was exceeded in 83 percent of all samples and for E. coli in 91 percent of samples for Olentangy River at Goodale Street. Compared to Olentangy River at Goodale Street, geometric means and single-samples exceeded the bathing-water standards somewhat less frequently for Scioto River at Town Street and far less frequently for Scioto River at Dublin Road Water Treatment Plant. In contrast to results for fecal-indicator bacteria, the differences between sites for pH and for concentrations for total alkalinity, total chloride, total nonfilterable residue, total nitrate plus nitrite as nitrogen, total phosphorus, and total organic carbon were small. The large contribution of streamflow and discharge of fecal-indicator bacteria from Olentangy River to Scioto River has a major effect on the Scioto River downstream from the confluence of Olentangy River during periods of rainfall and runoff. Fecal-indicator discharges were calculated for times before, during, and at 24-hour intervals for 48 to 72 hours after two runoff-producing storms. Fecal-coliform and E. coli concentrations were lower in samples collected before runoff and during receding streamflows at 24- to 48-hours after the storms than in samples collected during runoff. The fecal-indicator discharges entering Scioto River from Olentangy River ranged from 22.6 to nearly 100 percent of the total for two storms studied. Controlling nonpoint, unregulated,
Wicklein, Shaun M.
2004-01-01
Tributary streamflow to the St. Johns River in Duval County is thought to be affected by septic tank leachate from residential areas adjacent to these tributaries. Water managers and the city of Jacksonville have committed to infrastructure improvements as part of a management plan to address the impairment of tributary water quality. In order to provide data to evaluate the effects of future remedial activities in selected tributaries, major ion and nutrient concentrations, fecal coliform concentrations, detection of wastewater compounds, and tracking of bacterial sources were used to document septic tank influences on the water quality of selected tributaries. The tributaries Fishing Creek and South Big Fishweir Creek were selected because they drain subdivisions identified as high priority locations for septic tank phase-out projects: the Pernecia and Murray Hill B subdivisions, respectively. Population, housing (number of residences), and septic tank densities for the Murray Hill B subdivision are greater than those for the Pernecia subdivision. Water-quality samples collected in the study basins indicate influences from ground water and septic tanks. Estimated concentrations of total nitrogen ranged from 0.33 to 2.86 milligrams per liter (mg/L), and ranged from less than laboratory reporting limit (0.02 mg/L) to 0.64 mg/L for total phosphorus. Major ion concentrations met the State of Florida Class III surface-water standards; total nitrogen and total phosphorus concentrations exceeded the U.S. Environmental Protection Agency Ecoregion XII nutrient criteria for rivers and streams 49 and 96 percent of the time, respectively. Organic wastewater compounds detected at study sites were categorized as detergents, antioxidants and flame retardants, manufactured polycarbonate resins, industrial solvents, and mosquito repellent. The most commonly detected compound was para-nonylphenol, a breakdown product of detergent. Results of wastewater sampling give evidence that stream water in the study basins is affected by septic tank effluent. Fecal coliform bacteria concentrations were measured on a monthly basis; of 115 samples, 63 percent exceeded the State of Florida fecal coliform bacteria standard for Class III surface waters of 800 colonies per 100 milliliters of water on any 1 day. Fecal coliform bacteria concentrations ranged from less than 20 colonies per 100 milliliters of sample to greater than or equal to 160,000 colonies per 100 milliliters of sample. Antibiotic resistance patterns of fecal coliform bacteria were used to identify the sources of fecal coliform bacteria. Significant sources of fecal coliform bacteria included wild animals, dogs, and humans. A majority of the fecal coliform bacteria were classified to be from human sources. Because the primary source of fecal coliform bacteria is from human sources, and most likely septic tank effluent, management of human sources may substantially improve microbiological water quality in both the Fishing Creek and South Branch Big Fishweir Creek basins.
Pitkänen, Tarja; Paakkari, Piia; Miettinen, Ilkka T; Heinonen-Tanski, Helvi; Paulin, Lars; Hänninen, Marja-Liisa
2007-03-01
In this work alternative media for detection and enumeration of E. coli and coliform bacteria were compared to the reference method ISO 9308-1 (LTTC) using non-disinfected water samples with background flora. The alternative media included LES Endo agar medium (LES Endo), Colilert-18 with 51-well Quanti-tray (Colilert), Chromocult Coliform agar (CC), Harlequin E. coli/Coliform medium (HECM) and Chromogenic Escherichia coli/Coliform medium (CECM). A total of 110 samples of groundwater, bathing water and spiked water was used. Our results revealed that confirmation of coliform bacteria counts is necessary, not only on lactose-based LTTC and LES Endo media, but also on the chromogenic agar media tested, due to the growth of oxidase positive colonies. LTTC and CC media also allowed the growth of some morphologically typical coliform colonies containing gram-positive bacteria. The recovery of coliform bacteria was lower on LES Endo than on LTTC. In most cases Colilert, CC, HECM and CECM gave higher coliform counts than LTTC. The use of the LTTC medium led to higher E. coli counts than obtained with any of the alternative mediums. There are three explanations for this: (1) high sensitivity of LTTC, (2) false positives on LTTC or (3) false negatives especially with Colilert, but also with chromogenic agar media. Although LTTC was found to be a very sensitive medium, the high degree of background growth of non-disinfected waters disturbed substantially the use of it. In conclusion, our results suggest that Colilert, CC and CECM are potential alternative media for detection of coliform bacteria and E. coli from non-disinfected water.
Microorganisms in stormwater; a summary of recent investigations
Mallard, Gail E.
1980-01-01
All storm runoff contains a variety of bacteria, including total coliform, fecal coliform, and fecal streptococci, which are derived from the land over which the water flows. Most total coliform are native soil organisms, whereas the fecal coliform and fecal streptococci originate from the feces of wild and domestic animals. Urban runoff has been reported to contain pathogenic organisms, but this probably presents little direct threat to human health because the runoff is not ingested. Runoff water can, however, have other negative effects such as contamination of surface water, which may result in beach closures, or contamination of shellfish. This type of contamination is generally of short duration because indicator bacteria and pathogens die out rapidly in the aquatic environment. Similarly, bacteria and viruses deposited on soil by stormwater are inactivated by drying, competition from soil microflora, and a variety of other processes. Every storm producing runoff is unique in the number and type of microorganisms because these vary from site to site, from storm to storm, and during the course of the storm. Stormwater to be examined for microorganisms must be collected in sterile containers and processed immediately. (USGS)
Sea water quality assessment of Prince Islands' beaches in Istanbul.
Ilter Turkdogan Aydinol, F; Kanat, Gurdal; Bayhan, Hurrem
2012-01-01
In this study, seawater samples were subjected to microbiological and physicochemical analysis (water temperature, pH, Secchi disc depth and ammonia) in the Prince Islands which are located in Marmara Sea, being one of the most popular swimming areas in Istanbul. The monitoring program of the study has been carried out in the summer for 6 weeks at eight stations around the Prince Islands. Measured total coliform values were between 5 ± 2 and 26 ± 55 and faecal coliform values were between 4 ± 2 and 24 ± 50 in the monitoring stations. A statistical study has been conducted to find the relationship between total and faecal coliform concentrations, and t tests were applied. There was no significant difference in each location of the Islands, except one location. The results were evaluated by comparing with national and EU bathing water standards. Results of the study show that deep sea discharges and sea currents contribute dilution of coliform concentration in a positive way, and locations near coastal zones of the islands have acceptable values which are required by the regulations.
Zacarias Sylvestre, Silvia Helena; Lux Hoppe, Estevam Guilherme; de Oliveira, Roberto Alves
2014-01-01
The present work evaluated the performance of two treatment systems in reducing indicators of biological contamination in swine production wastewater. System I consisted of two upflow anaerobic sludge blanket (UASB) reactors, with 510 and 209 L in volume, being serially arranged. System II consisted of a UASB reactor, anaerobic filter, trickling filter, and decanter, being also organized in series, with volumes of 300, 190, 250, and 150 L, respectively. Hydraulic retention times (HRT) applied in the first UASB reactors were 40, 30, 20, and 11 h in systems I and II. The average removal efficiencies of total and thermotolerant coliforms in system I were 92.92% to 99.50% and 94.29% to 99.56%, respectively, and increased in system II to 99.45% to 99.91% and 99.52% to 99.93%, respectively. Average removal rates of helminth eggs in system I were 96.44% to 99.11%, reaching 100% as in system II. In reactor sludge, the counts of total and thermotolerant coliforms ranged between 105 and 109 MPN (100 mL)−1, while helminth eggs ranged from 0.86 to 9.27 eggs g−1 TS. PMID:24812560
Evaluation of future base-flow water-quality conditions in the Hillsborough River, Florida
Fernandez, Mario; Goetz, C.L.; Miller, J.E.
1984-01-01
A one-dimensional, steady-state, water-quality model was developed for a 30.0 mile reach of the Hillsborough River to evaluate water-quality conditions to be expected from future development. The model was calibrated and verified using data collected under critical base-flow conditions in April and December 1978. Dissolved organic nitrogen, nitrate nitrogen, and total and fecal coliforms were modeled for most of the study reach. Model results were used to evaluate the impacts of two typical housing developments on water-quality conditions in Tampa Reservoir. One development is located in the Cypress Creek basin and the other near the upper end of the study reach. Model results show development in the Hillsborough River basin may cause increased total and fecal coliform conditions. Simulated total coliforms at the Tampa water treatment plant for 1-, 3-, and 5-square-mile developments located in the Cypress Creek basin were 3,000, 5,400, and 8,300 colonies per 100 milliliters. Similar developments, however, located near the upper end of the study reach were 2,000, 3,600, and 5,100 colonies per 100 milliliters. Simulated fecal coliforms were 360, 700, and 100 and 180, 350, and 510 colonies per 100 milliliters, respectively. Other constituents modeled showed only minor increases in concentrations. (USGS)
NASA Astrophysics Data System (ADS)
Selvam, S.; Antony Ravindran, A.; Venkatramanan, S.; Singaraja, C.
2017-05-01
Heavy metals and microbiological contamination were investigated in groundwater in the industrial and coastal city of Thoothukudi. The main sources of drinking water in this area are water bores which are dug up to the depth of 10-50 m in almost every house. A number of chemical and pharmaceutical industries have been established since past three decades. Effluents from these industries are reportedly being directly discharged onto surrounding land, irrigation fields and surface water bodies forming point and non-point sources of contamination for groundwater in the study area. The study consists of the determination of physico-chemical properties, trace metals, heavy metals and microbiological quality of drinking water. Heavy metals were analysed using Inductively Coupled Plasma Mass Spectrometry and compared with the (WHO in Guidelines for drinking water quality, 2004) standards. The organic contamination was detected in terms of most probable number (MPN) test in order to find out faecal coliforms that were identified through biochemical tests. A comparison of the results of groundwater samples with WHO guidelines reveals that most of the groundwater samples are heavily contaminated with heavy metals like arsenic, selenium, lead, boron, aluminium, iron and vanadium. The selenium level was higher than 0.01 mg/l in 82 % of the study area and the arsenic concentration exceeded 0.01 mg/l in 42 % of the area. The results reveal that heavy metal contamination in the area is mainly due to the discharge of effluents from copper industries, alkali chemical industry, fertiliser industry, thermal power plant and sea food industries. The results showed that there are pollutions for the groundwater, and the total Coliform means values ranged from 0.6-145 MPN ml-1, faecal Coliform ranged from 2.2-143 MPN ml-1, Escherichia coli ranged from 0.9 to 40 MPN ml-1 and faecal streptococci ranged from 10-9.20 × 102 CFU ml-1. The coastal regions are highly contaminated with total coliform bacteria, faecal coliform bacteria and E. coli. This might be due to the mixing of sewage from Thoothukudi town through the Buckle channel and fishing activity.
Yedeme, Kokebe; Legese, Melese Hailu; Gonfa, Almaz; Girma, Somson
2017-01-01
Background: From swimming pools, bathers may acquire many potential pathogens or may be affected by the physicochemical characteristics of water used during bathing. Hence, this study aimed at assessing the physicochemical and microbiological quality of public swimming pools located at different hotels and recreation center in Addis Ababa, Ethiopia. Method: A cross sectional study was carried out from February to May, 2016. Nine hotels and one recreation center which recognized to have public swimming services were included. A total of 60 swimming pool water samples from 10 swimming pools were collected at deeper, shallow and intake point twice on a weekly basis using a 250 ml sterile bottle containing sodium thiosulphate. PH, residual chlorine and temperature of samples were recorded at the time of collection. Sample containing bottles were transported in ice box to microbiological laboratory and analyzed on the same day. Standard cultural and biochemical methods were used for isolation and characterization of the main microbial groups. Total viable count, total coliform count, fecal coliform count and E. coli were determined. Data was analyzed using SPSS Version 20. Results: Average PH and temperature of swimming pool water samples were 7.1 and 29oC respectively. Of all analyzed water samples, 58.4% (n=35/60) of them had PH range of 7.2-7.8, 58.3% (n=35/60) of samples had temperature in the range of 21oC-32oC and 25% (n=15/60) of water samples had residual chlorine in the range of 2-3mg/l. 73.3% (n=44/60) of the samples had a total viable count below 200 MPN/ml and 70% (n-42/60) of the samples had Total Coliform Count values less than 2 MPN/100 ml. Moreover, 66.7% (n=40/60) of the samples had fecal coliform counts falling below 1 MPN /100 ml. E. coli was absent in 70% (n=42/60) of the samples while it was present in 30% (n=18/60) of the samples. Conclusion: PH, residual chlorine and temperature value of majority of the swimming pools’ water samples were within the acceptable limit. Regarding microbial quality, most swimming pools’ water samples complied to the WHO standard. Swimming pools that did not comply to the standard both in physicochemical levels and microbial quality need improvement due to their significant health implication. PMID:28761562
NASA Astrophysics Data System (ADS)
Ribeiro Piffer, P.; Reverberi Tambosi, L.; Uriarte, M.
2017-12-01
One of the most pressing challenges faced by modern societies is ensuring a sufficient supply of water considering the ever-growing conflict between environmental conservation and expansion of agricultural and urban frontiers worldwide. Land use cover change have marked effects on natural landscapes, putting key watershed ecosystem services in jeopardy. We investigated the consequences of land use cover change and precipitation regimes on water quality in the state of São Paulo, Brazil, a landscape that underwent major changes in past century. Water quality data collected bi-monthly between 2000 and 2014 from 229 water monitoring stations was analyzed together with 2011 land use cover maps. We focused on six water quality metrics (dissolved oxygen, total nitrogen, total phosphorus, turbidity, total dissolved solids and fecal coliforms) and used generalized linear mixed models to analyze the data. Models were built at two scales, the entire watershed and a 60 meters riparian buffer along the river network. Models accounted for 46-67% of the variance in water quality metrics and, apart from dissolved oxygen, which reflected land cover composition in riparian buffers, all metrics responded to land use at the watershed scale. Highly urbanized areas had low dissolved oxygen and high fecal coliforms, dissolved solids, phosphorus and nitrogen levels in streams. Pasture was associated with increases in turbidity, while sugarcane plantations significantly increased nitrogen concentrations. Watersheds with high forest cover had greater dissolved oxygen and lower turbidity. Silviculture plantations had little impact on water quality. Precipitation decreased dissolved oxygen and was associated with higher levels of turbidity, fecal coliforms and phosphorus. Results indicate that conversion of forest cover to other land uses had negative impacts on water quality in the study area, highlighting the need for landscape restoration to improve watersheds ecosystem services.
Effect of ambient temperature storage on potable water coliform population estimations.
Standridge, J H; Delfino, J J
1983-01-01
The effect of the length of time between sampling potable water and performing coliform analyses has been a long-standing controversial issue in environmental microbiology. The issue is of practical importance since reducing the sample-to-analysis time may substantially increase costs for water analysis programs. Randomly selected samples (from those routinely collected throughout the State of Wisconsin) were analyzed for total coliforms after being held at room temperature (20 +/- 2 degrees C) for 24 and 48 h. Differences in results for the two holding times were compared with differences predicted by probability calculations. The study showed that storage of the potable water for up to 48 h had little effect on the public health significance of most samples containing more than two coliforms per 100 ml. PMID:6651296
Giannuzzi, L.; Carvajal, G.; Corradini, M. G.; Araujo Andrade, C.; Echenique, R.; Andrinolo, D.
2012-01-01
Water samples were collected during 3 years (2004–2007) at three sampling sites in the Rio de la Plata estuary. Thirteen biological, physical, and chemical parameters were determined on the water samples. The presence of microcystin-LR in the reservoir samples, and also in domestic water samples, was confirmed and quantified. Microcystin-LR concentration ranged between 0.02 and 8.6 μg.L−1. Principal components analysis was used to identify the factors promoting cyanobacteria growth. The proliferation of cyanobacteria was accompanied by the presence of high total and fecal coliforms bacteria (>1500 MNP/100 mL), temperature ≥25°C, and total phosphorus content ≥1.24 mg·L−1. The observed fluctuating patterns of Microcystis aeruginosa, total coliforms, and Microcystin-LR were also described by probabilistic models based on the log-normal and extreme value distributions. The sampling sites were compared in terms of the distribution parameters and the probability of observing high concentrations for Microcystis aeruginosa, total coliforms, and microcystin-LR concentration. PMID:22523486
NASA Astrophysics Data System (ADS)
Soo, Chen-Lin; Ling, Teck-Yee; Lee, Nyanti; Apun, Kasing
2016-03-01
The concentrations of nutrients (nitrogen and phosphorus), total metals, and fecal coliform (FC) coupling with chlorophyll- a (chl- a), 5-day biochemical oxygen demand (BOD5) and other general environmental parameters were evaluated at the sub-surface and near-bottom water columns of 13 stations in the Sibu Laut River during low and high slack waters. The results indicated that inorganic nitrogen (mainly nitrate) was the primary form of nitrogen whereas organic phosphorus was the major form of phosphorus. The abundance of total heavy metals in Sibu Laut River and its tributaries was in the order of Pb < Cu < Zn < Cd. Fecal coliform concentration was relatively low along Sibu Laut River. The shrimp farm effluents contributed a substantial amount of chl- a, BOD5, nutrients, and FC to the receiving creek except for total metals. Nevertheless, the influence was merely noticeable in the intake creek and amended rapidly along Selang Sibu River and brought minimal effects on the Sibu Laut River. Besides, the domestic sewage effluents from villages nearby also contributed a substantial amount of pollutants.
Sexton, Jonathan D; Tanner, Benjamin D; Maxwell, Sheri L; Gerba, Charles P
2011-10-01
Recent scientific literature suggests that portable steam vapor systems are capable of rapid, chemical-free surface disinfection in controlled laboratory studies. This study evaluated the efficacy of a portable steam vapor system in a hospital setting. The study was carried out in 8 occupied rooms of a long-term care wing of a hospital. Six surfaces per room were swabbed before and after steam treatment and analyzed for heterotrophic plate count (HPC), total coliforms, methicillin-intermediate and -resistant Staphylococcus aureus (MISA and MRSA), and Clostridium difficile. The steam vapor device consistently reduced total microbial and pathogen loads on hospital surfaces, to below detection in most instances. Treatment reduced the presence of total coliforms on surfaces from 83% (40/48) to 13% (6/48). Treatment reduced presumptive MISA (12/48) and MRSA (3/48) to below detection after cleaning, except for 1 posttreatment isolation of MISA (1/48). A single C difficile colony was isolated from a door push panel before treatment, but no C difficile was detected after treatment. The steam vapor system reduced bacterial levels by >90% and reduced pathogen levels on most surfaces to below the detection limit. The steam vapor system provides a means to reduce levels of microorganisms on hospital surfaces without the drawbacks associated with chemicals, and may decrease the risk of cross-contamination. Copyright © 2011 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
40 CFR 432.125 - New source performance standards (NSPS).
Code of Federal Regulations, 2010 CFR
2010-07-01
... BOD5 26 16 Fecal Coliform (2) (3) O&G (as HEM) 14 8.0 TSS 30 20 1 mg/L (ppm). 2 Maximum of 400 MPN or... Ammonia (as N) 8.0 4.0 BOD5 26 16 Fecal Coliform (2) (3) O&G (as HEM) 14 8.0 TSS 30 20 Total Nitrogen 147...
40 CFR 432.115 - New source performance standards (NSPS).
Code of Federal Regulations, 2011 CFR
2011-07-01
... Coliform ( 2 ) ( 3 ) O&G (as HEM) 14 8.0 TSS 30 20 1 mg/L (ppm). 2 Maximum of 400 MPN or CFU per 100 mL at... Coliform (2) (3) O&G (as HEM) 14 8.0 TSS 30 20 Total Nitrogen 147 103 1 mg/L (ppm). 2 Maximum of 400 MPN or...
40 CFR 432.125 - New source performance standards (NSPS).
Code of Federal Regulations, 2011 CFR
2011-07-01
... BOD5 26 16 Fecal Coliform (2) (3) O&G (as HEM) 14 8.0 TSS 30 20 1 mg/L (ppm). 2 Maximum of 400 MPN or... Ammonia (as N) 8.0 4.0 BOD5 26 16 Fecal Coliform (2) (3) O&G (as HEM) 14 8.0 TSS 30 20 Total Nitrogen 147...
40 CFR 432.115 - New source performance standards (NSPS).
Code of Federal Regulations, 2010 CFR
2010-07-01
... Coliform ( 2 ) ( 3 ) O&G (as HEM) 14 8.0 TSS 30 20 1 mg/L (ppm). 2 Maximum of 400 MPN or CFU per 100 mL at... Coliform (2) (3) O&G (as HEM) 14 8.0 TSS 30 20 Total Nitrogen 147 103 1 mg/L (ppm). 2 Maximum of 400 MPN or...
Microbial Survey of Pennsylvania Surface Water Used for Irrigating Produce Crops.
Draper, Audrey D; Doores, Stephanie; Gourama, Hassan; LaBorde, Luke F
2016-06-01
Recent produce-associated foodborne illness outbreaks have been attributed to contaminated irrigation water. This study examined microbial levels in Pennsylvania surface waters used for irrigation, relationships between microbial indicator organisms and water physicochemical characteristics, and the potential use of indicators for predicting the presence of human pathogens. A total of 153 samples taken from surface water sources used for irrigation in southeastern Pennsylvania were collected from 39 farms over a 2-year period. Samples were analyzed for six microbial indicator organisms (aerobic plate count, Enterobacteriaceae, coliform, fecal coliforms, Escherichia coli, and enterococci), two human pathogens (Salmonella and E. coli O157), and seven physical and environmental characteristics (pH, conductivity, turbidity, air and water temperature, and sampling day and 3-day-accumulated precipitation levels). Indicator populations were highly variable and not predicted by water and environmental characteristics. Only five samples were confirmed positive for Salmonella, and no E. coli O157 was detected in any samples. Predictive relationships between microbial indicators and the occurrence of pathogens could therefore not be determined.
Assessment of the quality of water from hand-dug wells in ghana.
Nkansah, Marian Asantewah; Boadi, Nathaniel Owusu; Badu, Mercy
2010-04-26
This study focused upon the determination of physicochemical and microbial properties, including metals, selected anions and coliform bacteria in drinking water samples from hand-dug wells in the Kumasi metropolis of the Republic of Ghana. The purpose was to assess the quality of water from these sources. Ten different water samples were taken from different parts of Kumasi, the capital of the Ashanti region of Ghana and analyzed for physicochemical parameters including pH, electrical conductivity, total dissolved solids, alkalinity total hardness and coliform bacteria. Metals and anions analyzed were Ca, Mg, Fe, Mn, NO(3) (-), NO(2) (-), SO(4) (2-), PO(4) (2-), F(-) and Cl(-). Bacteria analysed were total coliform and Escherichia coli.THE DATA SHOWED VARIATION OF THE INVESTIGATED PARAMETERS IN SAMPLES AS FOLLOWS: pH, 6.30-0.70; conductivity (EC), 46-682 muS/cm; PO(4) (3-), 0.67-76.00 mg/L; F(-), 0.20-0.80 mg/L; NO(3) (-), 0-0.968 mg/L; NO(2) (-), 0-0.063 mg/L; SO(4) (2-), 3.0-07.0 mg/L; Fe, 0-1.2 mg/L; Mn, 0-0.018 mg/L. Total coliform and Escherichia coli were below the minimum detection limit (MDL) of 20 MPN per 100 ml in all the samples. The concentrations of most of the investigated parameters in the drinking water samples from Ashanti region were within the permissible limits of the World Health Organization drinking water quality guidelines.
Assessment of Water Quality in Asa River (Nigeria) and Its Indigenous Clarias gariepinus Fish
Kolawole, Olatunji M.; Ajayi, Kolawole T.; Olayemi, Albert B.; Okoh, Anthony I.
2011-01-01
Water is a valued natural resource for the existence of all living organisms. Management of the quality of this precious resource is, therefore, of special importance. In this study river water samples were collected and analysed for physicochemical and bacteriological evaluation of pollution in the Unity Road stream segment of Asa River in Ilorin, Nigeria. Juvenile samples of Clarias gariepinus fish were also collected from the experimental Asa River and from the control Asa Dam water and were analysed for comparative histological investigations and bacterial density in the liver and intestine in order to evaluate the impact of pollution on the aquatic biota. The water pH was found to range from 6.32 to 6.43 with a mean temperature range of 24.3 to 25.8 °C. Other physicochemical parameters monitored including total suspended solids, total dissolved solids, biochemical oxygen demand and chemical oxygen demand values exceeded the recommended level for surface water quality. Results of bacteriological analyses including total heterotrophic count, total coliform and thermotolerant coliform counts revealed a high level of faecal pollution of the river. Histological investigations revealed no significant alterations in tissue structure, but a notable comparative distinction of higher bacterial density in the intestine and liver tissues of Clarias gariepinus from Asa River than in those collected from the control. It was inferred that the downstream Asa River is polluted and its aquatic biota is bacteriologically contaminated and unsafe for human and animal consumption. PMID:22163210
Obiri-Danso, K; Adonadaga, M G; Hogarh, J N
2011-01-01
The effect of agrochemical use in agricultural activities on the drinking water quality of ground and surface water within Agogo, a prominent tomato growing area in the Ashanti region of Ghana was assessed by monitoring physicochemical parameters, trace metals and microbial quality of two water sources. Levels of contamination were greater in surface water than groundwater. Trace metal levels (mg/L) were 1.40, 0.12, 0.08 and 0.18 in surface water and 0.08, 0.10, 0.05 and 0.08 in groundwater for Fe, Pb, Zn and Cd, respectively. Lead and Cd in surface and groundwater exceeded USEPA maximum acceptable levels (MCLs) for drinking water. Bacterial indicator numbers (geometric means/100 mL) in surface water varied from 9.35 x 10⁵ to 1.57 x 10¹¹ for total coliforms, 4.15 x 10⁴ to 2.10 x 10⁷ for faecal coliforms and 2.80 x 10 to 3.25 x 10² for enterococci, but none was found in groundwater.
Hagler, A N; Rosa, C A; Morais, P B; Mendonça-Hagler, L C; Franco, G M; Araujo, F V; Soares, C A
1993-10-01
Yeasts and coliform bacteria were isolated from water that accumulated in the central cups and adjacent leaf axilae of two bromeliads, Neoregelia cruenta of a coastal sand dune and Quesnelia quesneliana of a mangrove ecosystem near the city of Rio de Janeiro, Brazil. The mean total coliform counts were above 10,000 per 100 mL for waters of both plants, but the mean fecal coliform counts were only 74 per 100 mL for Q. quesneliana and mostly undetected in water from N. cruenta. Of 90 fecal coliform isolates, 51 were typical of Escherichia coli in colony morphology and indol, methyl red, Volges-Proskauer, and citrate (IMViC) tests. Seven representatives of the typical E. coli cultures were identified as this species, but the identifications of nine other coliform bacteria were mostly dubious. The yeast community of N. cruenta was typical of plant surfaces with basidiomycetous yeasts anamorphs, and the black yeast Aureobasidium pullulans was prevalent. Quesnelia quesneliana had a substantial proportion of ascomycetous yeasts and their anamorphs, including a probable new biotype of Saccharomyces unisporus. Our results suggested that the microbial communities in bromeliad waters are typically autochtonous and not contaminants.
Pipes, W O; Minnigh, H A; Moyer, B; Troy, M A
1986-01-01
A total of 2,601 water samples from six different water systems were tested for coliform bacteria by Clark's presence-absence (P-A) test and by the membrane filter (MF) method. There was no significant difference in the fraction of samples positive for coliform bacteria for any of the systems tested. It was concluded that the two tests are equivalent for monitoring purposes. However, 152 samples were positive for coliform bacteria by the MF method but negative by the P-A test, and 132 samples were positive by the P-A test but negative by the MF method. Many of these differences for individual samples can be explained by random dispersion of bacteria in subsamples when the coliform density is low. However, 15 samples had MF counts greater than 3 and gave negative P-A results. The only apparent explanation for most of these results is that coliform bacteria were present in the P-A test bottles but did not produce acid and gas. Two other studies have reported more samples positive by Clark's P-A test than by the MF method. PMID:3532953
1980-01-01
In a multi-laboratory trial, minerals-modified glutamate medium (MMGM) was compared with lauryl tryptose lactose broth (LTLB) in the multiple tube method for the enumeration of coliform organisms, including Escherichia coli, in water. Samples of raw and chlorinated waters yielded a total of 2313 positive tube-reactions with MMGM and 2174 with LTLB. These were interpreted either as E. coli; other coliform organisms; or as false positive reactions. The results at first reading (18 or 24 h) and at 48 h have been analysed statistically in terms of (i) most probable numbers of coliform organisms; (ii) positive reactions and their interpretation; and (iii) whether or not the sample yielded any E. coli or other coliform organisms. All three analyses indicated the same trends. For the detection of E. coli in raw waters LTLB was better than MMGM at 18-24 h, but MMGM was better at 48 h with waters containing small numbers of coliform organisms; for raw waters with greater numbers of organisms, both media performed equally well. Analysis of a subset of samples read at both 18 and 24 h indicated that the superiority of LTLB over MMGM with raw waters disappeared by 24 h. For chlorinated waters, LTLB yielded more positive gas reactions at 18-24 h, but fewer of these were E. coli than with MMGM; at 48 h MMGM was clearly better than LTLB for total coliform organisms including E. coli--especially if the numbers were small. MMGM therefore remains the medium of choice for the detection of E. coli as an indicator of faecal contamination of chlorinated drinking water supplies. It is also better for the detection of small numbers of E. coli in other waters. PMID:6762395
Monitoring of urban and rural basins: water quality of Mourão basin.
Passig, F H; Lima, S B; Carvalho, K Q; Halmeman, M C R; Souza, P C; Gusmão, L K
2015-12-01
The Mourão River basin is located on the central western region of the Paraná State - Brazil, between coordinates 23º 44' - 24º 25 South latitude and 52º 12' - 52º 30' West longitude, between 270 and 820 m above sea level, and 1,648.21 km2 drainage area. Water quality was evaluated by monitoring physical, chemical and microbiological parameters. Monthly samplings were performed for a year at five sites in the basin for analysis of: pH, temperature, dissolved oxygen, biochemical oxygen demand, total nitrogen, ammoniacal nitrogen, nitrite, nitrate, total phosphorus, turbidity, total solids, volatile solids and fecal coliforms. The results of the evaluated parameters showed higher values than the limits set by CONAMA Resolution 357 from 2005 for Class 2 in some samples. The Water Quality Index (WQI) indicated that 72% of samples had average quality and 28% had good quality for the Mourão River basin. Higher values of WQI were observed after rainfall period with median of 75 compared to the dry period with median of 62. The source of the Mourão River is contaminated with fecal coliforms, evidencing the real need to treat sewage in rural areas.
NASA Astrophysics Data System (ADS)
Tekpor, M.; Akrong, M. O.; Asmah, M. H.; Banu, R. A.; Ansa, E. D. O.
2017-09-01
The study was carried out to determine the bacteriological safety of water in hand-dug wells in the Atebubu-Amantin District of the Brong-Ahafo Region in Ghana. A total of 60 samples were collected from ten hand dug wells and analysed for total coliform (TC), faecal coliform (FC), E. coli (EC), Salmonella spp. (SP) and Enterococcus spp. (ES). Data was collected in both the rainy and the dry seasons. The results obtained showed that water from all the wells in the study area did not meet the World Health Organisation guideline and Ghana standard for drinking water of zero (0) coliform forming unit (cfu) per 100 ml for TC, FC, EC, SP and ES, respectively. Contamination was found to be high in the wells during the wet season as compared to the dry season. Wells (A1 to A5) which were close to septic tanks had high bacteria counts in both seasons. The total coliform counts ranged from 2.98 to 5.93 log cfu/100 ml in the wet season and 3.10-5.03 log cfu/100 ml in the dry season. There was drastic reduction of faecal coliform count from a range of 2.78-4.55 log cfu/100 ml in the wet season to 1.70-3.51 log cfu/100 ml in the dry season. The high bacteria count in wells A1 to A5 could be attributed to the closeness of the wells to the septic tank, and contaminant transport through the saturated underground zones. It is recommended that the water should be treated properly before drinking.
Karra, Styliani; Katsivela, Eleftheria
2007-03-01
Measurements were conducted at a Mediterranean site (latitude 35 degrees 31' north and longitude 24 degrees 03' east) during summer, to study the concentration of microorganisms emitted from a wastewater treatment plant under intensive solar radiation (520-840 W/m2) and at elevated air temperatures (25-31 degrees C). Air samples were taken with the Air Sampler MAS 100 (Merck) at each stage of an activated-sludge wastewater treatment (pretreatment, primary settling tanks, aeration tanks, secondary settling tanks, chlorination, and sludge processors). Cultivation methods based on the viable counts of mesophilic heterotrophic bacteria, as well as of indicator microorganisms of faecal contamination (total and faecal coliforms and enterococci), and fungi were performed. During air sampling, temperature, solar radiation, relative humidity and wind speed were measured. The highest concentrations of airborne microorganisms were observed at the aerated grit removal of wastewater at the pretreatment stage. A gradual decrease of bioaerosol emissions was observed during the advanced wastewater treatment from the pretreatment to the primary, secondary and tertiary treatment (97.4% decrease of mesophilic heterotrophic bacteria, and 100% decrease of total coliforms, faecal coliforms and enterococci), 95.8% decrease of fungi. The concentration of the airborne microorganisms at the secondary and tertiary treatment of the wastewater was lower than in the outdoor control. At the same time, the reduction of the microbial load at the waste sludge processors was 19.7% for the mesophilic heterotrophic bacteria, 99.4% for the total coliforms, and 100% for the faecal coliforms and the enterococci, 84.2% for the fungi. The current study concludes that the intensive solar radiation, together with high ambient temperatures, as well as optimal wastewater treatment are the most important factors for low numbers of microbes in the air.
Reed, Brian C; Rasnake, Mark S
2016-03-01
Hikers and campers are exposed to risks while in the wilderness. One of these risks is the possibility of contracting an illness, including infectious diarrhea. This project tested for coliform bacteria in water samples taken near popular Appalachian Trail shelters. Water was collected from access points within the Great Smoky Mountains National Park. Samples were collected in sterile bottles and inoculated on a commercially available coliform detection kit for quantitative determination of total coliform and Escherichia coli counts. Water samples were taken during summer and fall seasons. During summer, 7 of 10 samples were positive for coliform bacteria and 6 of those 7 for E coli. The most probable number (MPN) of colony-forming units (CFU) for coliform bacteria ranged from 0 to 489 CFU/100 mL, with the MPN for E coli varying from 0 to 123 CFU/100 mL. These data differed from the fall collection, revealing 3 of 7 samples positive for coliform bacteria and 1 of those 3 for E coli. The MPN of CFU for coliform bacteria in fall samples varied from 0 to 119 CFU/100 mL and 0 to 5 to CFU/100 mL for E coli. Environmental Protection Agency drinking water standards set the standard of 0 CFU/100 mL to be considered safe. This analysis of water samples along the Appalachian Trail emphasizes that the majority of water access points require treatment during the summer season. Coliform burden was not as high through the fall months. These data suggest one infectious disease risk for wilderness travelers. Copyright © 2016 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.
The impact of hygiene and localised treatment on the quality of drinking water in Masaka, Rwanda.
Uwimpuhwe, Monique; Reddy, Poovendhree; Barratt, Graham; Bux, Faizal
2014-01-01
The worldwide prevalence of waterborne diseases has been attributed to the lack of safe water, inadequate sanitation and hygiene. This study evaluated socio-demographic factors, microbiological quality of water at source and point of use (POU) at households, water handling and sanitation practices in a rural Rwandan community. Thirty five water samples from the source, Nyabarongo River, and water at point of use (POU) treated with the Slow Sand Filter (SSF) and Sûr'Eau methods, were analysed for total coliform and faecal coliform counts. Turbidity was measured in household samples. A structured questionnaire regarding water collection, storage, usage and waterborne disease awareness was administered to 324 women. Despite the significant reduction in coliforms and faecal coliforms from the Nyabarongo River following treatment using either SSF or Sûr'Eau, the water at point of use was found to be unsafe for human consumption. The frequency of diarrheal diseases were significantly higher among people who did not wash hands before food preparation (P = 0.002) and after using a toilet (P = 0.007) than among those who did. There was a statistically significant association between education levels and water treatment practices at the households (P < 0.05). Participants had limited knowledge regarding water storage practices for prevention of household water contamination. A combination of treatment methods with appropriate water handling should be considered. In addition, education is a fundamental precursor to advocating water treatment at POU.
Mdluli, Fezile; Thamaga-Chitja, Joyce; Schmidt, Stefan
2013-01-01
During October, November and December 2011 (when highest sales of Agri-Hub fresh produce are observed), irrigation water, compost, lettuce and spinach sampled from four different farmer cooperatives supplying the local Agri-Hub in uMbumbulu (KwaZulu-Natal, South Africa) were analyzed monthly for the presence of total and fecal coliforms and Escherichia coli using the most probable number (MPN) technique. The pH values for all irrigation water samples analyzed were within the acceptable range of 6.5–8.5 for agricultural use. Fecal coliform levels were <1,000 MPN per 100 mL irrigation water and <1,000 MPN per g of compost. The vegetables produced by Agri-Hub small-scale farmers met the requirements for total coliforms of <200/g set by the South African Department of Health at the time of sampling. E. coli MPN values for irrigation water and vegetables were below the limit of detection. In addition, the farming practices of 73 farmers were assessed via a survey. The results revealed that more than 40% of farmers used microbiologically safe tap water for irrigation and that trained farmers have a significantly better understanding of the importance of production hygiene than untrained farmers. These results reiterate the importance of interventions that build capacity in the area of food safety and hygiene of small-scale farmers for market access of formal value chains. PMID:24065036
Mdluli, Fezile; Thamaga-Chitja, Joyce; Schmidt, Stefan
2013-09-13
During October, November and December 2011 (when highest sales of Agri-Hub fresh produce are observed), irrigation water, compost, lettuce and spinach sampled from four different farmer cooperatives supplying the local Agri-Hub in uMbumbulu (KwaZulu-Natal, South Africa) were analyzed monthly for the presence of total and fecal coliforms and Escherichia coli using the most probable number (MPN) technique. The pH values for all irrigation water samples analyzed were within the acceptable range of 6.5-8.5 for agricultural use. Fecal coliform levels were <1,000 MPN per 100 mL irrigation water and <1,000 MPN per g of compost. The vegetables produced by Agri-Hub small-scale farmers met the requirements for total coliforms of <200/g set by the South African Department of Health at the time of sampling. E. coli MPN values for irrigation water and vegetables were below the limit of detection. In addition, the farming practices of 73 farmers were assessed via a survey. The results revealed that more than 40% of farmers used microbiologically safe tap water for irrigation and that trained farmers have a significantly better understanding of the importance of production hygiene than untrained farmers. These results reiterate the importance of interventions that build capacity in the area of food safety and hygiene of small-scale farmers for market access of formal value chains.
Molina-Navarro, E; Martínez-Pérez, S; Sastre-Merlín, A; Soliveri, J; Fernández-Monistrol, I; Copa-Patiño, J L
2011-03-01
Bordering on the edge of the Entrepeñas reservoir (Guadalajara, Spain), next to the village of Pareja, a small dam that allows a body of water to develop with a constant level has been built. Initiatives like this (which we have termed "limno-reservoirs") are innovative in Spain and around the world. Earlier reservoirs such as this one were constructed to create a habitat for birds, but the Pareja limno-reservoir is the first to promote socio-economic development. In order to study this limno-reservoir, this research group set up an environmental observatory, analyzing, among other variables, microbiological water quality and nutrient content. After a year and a half of research, it was observed that the concentration of microorganisms is lower in the limno-reservoir than in the river that feeds it, possibly due to the nutrient depletion in the lentic ecosystem. In the limno-reservoir, the total coliforms and enterococci concentrations fall within the European Bathing Water Directive limits, but in the river these concentrations are sometimes higher. The nutrient load in the limno-reservoir is low, with nutrient variations influencing native microorganisms, but not for total coliforms and enterococci. However, the development of special conditions in the bottom has been observed in winter, facilitating coliforms and enterococci survival. This research is very interesting since the creation of limno-reservoirs is rising in Spain and no research is being done on their behaviour. Copyright © 2010 Elsevier Ltd. All rights reserved.
Quality evaluation of processed clay soil samples
Steiner-Asiedu, Matilda; Harrison, Obed Akwaa; Vuvor, Frederick; Tano-Debrah, Kwaku
2016-01-01
Introduction This study assessed the microbial quality of clay samples sold on two of the major Ghanaian markets. Methods The study was a cross-sectional assessing the evaluation of processed clay and effects it has on the nutrition of the consumers in the political capital town of Ghana. The items for the examination was processed clay soil samples. Results Staphylococcus spp and fecal coliforms including Klebsiella, Escherichia, and Shigella and Enterobacterspp were isolated from the clay samples. Samples from the Kaneshie market in Accra recorded the highest total viable counts 6.5 Log cfu/g and Staphylococcal count 5.8 Log cfu/g. For fecal coliforms, Madina market samples had the highest count 6.5 Log cfu/g and also recorded the highest levels of yeast and mould. For Koforidua, total viable count was highest in the samples from the Zongo market 6.3 Log cfu/g. Central market samples had the highest count of fecal coliforms 4.6 Log cfu/g and yeasts and moulds 6.5 Log cfu/g. “Small” market recorded the highest staphylococcal count 6.2 Log cfu/g. The water activity of the clay samples were low, and ranged between 0.65±0.01 and 0.66±0.00 for samples collected from Koforidua and Accra respectively. Conclusion The clay samples were found to contain Klebsiella spp. Escherichia, Enterobacter, Shigella spp. staphylococcus spp., yeast and mould. These have health implications when consumed. PMID:27642456
Pant, Narayan Dutt; Poudyal, Nimesh; Bhattacharya, Shyamal Kumar
2016-06-07
Water-related diseases are of great concern in developing countries like Nepal. Every year, there are countless morbidity and mortality due to the consumption of unsafe drinking water. Recently, there have been increased uses of bottled drinking water in an assumption that the bottled water is safer than the tap water and its use will help to protect from water-related diseases. So, the main objective of this study was to analyze the bacteriological quality of bottled drinking water and that of municipal tap water. A total of 100 samples (76 tap water and 24 bottled water) were analyzed for bacteriological quality and pH. The methods used were spread plate method for total plate count (TPC) and membrane filter method for total coliform count (TCC), fecal coliform count (FCC), and fecal streptococcal count (FSC). pH meter was used for measuring pH. One hundred percent of the tap water samples and 87.5 % of the bottled water samples were found to be contaminated with heterotrophic bacteria. Of the tap water samples, 55.3 % were positive for total coliforms, compared with 25 % of the bottled water. No bottled water samples were positive for fecal coliforms and fecal streptococci, in contrast to 21.1 % and 14.5 % of the tap water samples being contaminated with fecal coliforms and fecal streptococci, respectively. One hundred percent of the tap water samples and 54.2 % of the bottled water samples had pH in the acceptable range. All of the municipal tap water samples and most of the bottled drinking water samples distributed in Dharan municipality were found to be contaminated with one or more than one type of indicator organisms. On the basis of our findings, we may conclude that comparatively, the bottled drinking water may have been safer (than tap water) to drink.
Effect of wastewater quality parameters on coliform inactivation by tin oxide anodes.
Teel, Amy L; Watts, Richard J
2018-04-16
The effect of six water quality constituents on wastewater effluent disinfection by tin oxide anodes (TOAs) was investigated in single cell laboratory reactors. Several concentrations of suspended solids, chemical oxygen demand (COD), alkalinity, ammonia-nitrogen, nitrite-nitrogen, and nitrate-nitrogen were added to media containing 10 6 total coliform bacteria mL -1 . Current was applied through the TOAs, and coliform bacteria viability was analyzed over time. Over 99.9% inactivation of coliform bacteria was found over 15 min in TOA reactors. Concentrations of the six water quality constituents typical of concentrations found in wastewaters had no effect on TOA disinfection efficacy. The results of this research demonstrate that TOAs, which could potentially be powered by solar panels, have potential as a sustainable disinfection process compared to chlorine, ozone, and ultraviolet light.
Coliform inhibition by bacteriocin-like substances in drinking water distribution systems.
Means, E G; Olson, B H
1981-01-01
Bacterial isolates from an unchlorinated potable groundwater system and a chlorinated surface water system were screened by an agar overlay method for the ability to produce bacteriocin-like substances (BLS) inhibitory to the growth of Escherichia coli, Klebsiella sp., and Enterobacter aerogenes. The production of coliform-specific BLS by noncoliform bacteria varied with the site and date of isolation as well as the genus of the producer strain. A total of 448 bacterial isolates were screened from the chlorinated system, and 22.1% produced BLS specific for at least one of the three coliforms. In the unchlorinated system, 7.9% (n = 696) possessed this ability. Flavobacterium/Moraxella comprised 57.1% of all bacteria (from both systems) producing BLS. The possibility that BLS interfere with coliform detection in standard bacteriological water quality tests is discussed. Images PMID:7027953
Water-quality investigations of the Jordan River, Salt Lake County, Utah, 1980-82
Stephens, D.W.
1984-01-01
Water-quality studies were conducted on the Jordan River, Utah, to investigate specific problems: dissolved oxygen, toxic substances, sanitary quality, and turbidity and suspended sediment. The dissolved oxygen decreased from 8 milligrams per liter at the Jordan Narrows to less than 5 milligrams per liter at 500 North Street. Chemical oxygen demand increased about 23 percent and biochemical oxygen demand increased 90 percent. Nearly 78 percent of the water samples analyzed for total mercury exceeded the State intended-use standard of 0.05 microgram per liter. Concentrations of ammonia, cadmium, copper, lead, and zinc exceeded the standards periodically. The pesticides DDD, DDE, DDT, dieldrin, methoxychlor, and 2,4-D were occasionally detected in bottom materials. Most were present in quantities of less than 15 micrograms per kilogram. Concentrations of three indicator bacteria (total coliform, fecal coliform, and fecal streptococcus) increased in a downstream direction. Concentrations of total coliform bacteria often exceeded 5,000 colonies per 100 milliliters and concentrations of fecal coliform bacteria often exceeded 2,000 colonies per 100 milliliters. The primary sources of turbidity in the Jordan River are Utah Lake and discharges from the wastewater-treatment plants. Large values of turbidity were measured at the Jordan Narrows with a summer mean value of 88 nephelometer turbidity units (NTU) and a winter mean value of 43 NTU. (USGS)
Luo, Kun; Hu, Xuebin; He, Qiang; Wu, Zhengsong; Cheng, Hao; Hu, Zhenlong; Mazumder, Asit
2017-04-01
Rapid urbanization in China has been causing dramatic deterioration in the water quality of rivers and threatening aquatic ecosystem health. In this paper, multivariate techniques, such as factor analysis (FA) and cluster analysis (CA), were applied to analyze the water quality datasets for 19 rivers in Liangjiang New Area (LJNA), China, collected in April (dry season) and September (wet season) of 2014 and 2015. In most sampling rivers, total phosphorus, total nitrogen, and fecal coliform exceeded the Class V guideline (GB3838-2002), which could thereby threaten the water quality in Yangtze and Jialing Rivers. FA clearly identified the five groups of water quality variables, which explain majority of the experimental data. Nutritious pollution, seasonal changes, and construction activities were three key factors influencing rivers' water quality in LJNA. CA grouped 19 sampling sites into two clusters, which located at sub-catchments with high- and low-level urbanization, respectively. One-way ANOVA showed the nutrients (total phosphorus, soluble reactive phosphorus, total nitrogen, ammonium nitrogen, and nitrite), fecal coliform, and conductivity in cluster 1 were significantly greater than in cluster 2. Thus, catchment urbanization degraded rivers' water quality in Liangjiang New Area. Identifying effective buffer zones at riparian scale to weaken the negative impacts of catchment urbanization was recommended.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-10
...--Wilson-Clinton Hwy to Fecal Coliform entrance of White Bayou (East Baton Rouge Parish) (Scenic). 040103 Comite River--Entrance of White Bayou to Fecal Coliform. Amite River. 040201 Bayou Manchac--Headwaters to.... Canal to mouth at Lake Maurepas (Scenic). 040903 Bayou Cane--Headwaters to U.S. Hwy 190 TSS. (Scenic...
Microbiological quality and safety of cooking butter in Beni-Suef governorate-Egypt.
Meshref, A M S
2010-06-01
Cooking butter is one of the most popular types of fat consumed in Egyptian houses. It is produced in villages by rural women that are usually using their traditional knowledge during manufacturing. To study the rate of contamination and hygienic quality of cooking butter A total of 60 random samples of cooking butter, were collected from different farmers' houses in different villages, Beni-Suef Governorate, Egypt. Cooking butter samples were examined for psychrotrophic bacteria, total coliforms, faecal coliforms and molds and yeasts counts. Additionally examination for the presence of pathogenic bacteria like E.coli, S.aureus and Ps.aeruginosa were also performed. The microbiological examination revealed that 100, 100, 36.7, 31.7, 31.7 and 23.3% of the examined samples were contaminated by psychrotrophic bacteria, molds and yeasts, coliforms, faecal coliforms, E.coli and S.aureus, respectively. None of the examined cooking butter samples contained Ps.aeruginosa. The means values of sodium chloride and titratable acidity were 0.57 ± 0.05 % and 0.20 ± 0.013%, respectively. The present study showed that cooking butter is produced under unhygienic condition and without good manufacturing practice. The Public health significance and suggestive control measures are discussed.
Sisay, Tadesse; Beyene, Abebe; Alemayehu, Esayas
2017-10-18
The failure to provide safe drinking water services to all people is the greatest development setback of the twenty-first century including Ethiopia. Potential pollutants from various sources are deteriorating drinking water quality in different seasons, and associated health risks were not clearly known. We determined seasonal and spatial variations of urban drinking water characteristics and associated health risks in Agaro, Jimma, and Metu towns, Southwest Ethiopia. Seventy-two samples were collected during dry and rainy seasons of 2014 and 2015. The majority (87.4%) of physicochemical parameters was found within the recommended limits. However, free residual chlorine in Jimma and Agaro town water sources was lower than the recommended limit and negatively correlated with total and fecal coliform counts (r = - 0.585 and - 0.638). Statistically significant differences were observed at pH, turbidity, and total coliform between dry and rainy seasons (p < 0.05). A Kruskal-Wallis H test revealed a statistically significant difference in electrical conductivity, total hardness, fluoride, iron, and fecal coliform across the study towns (p < 0.05). The Agaro town water source was the highest in fluoride concentration (3.15 mg/l). The daily exposure level for high fluoride concentration in Agaro town was estimated between 0.19 and 0.41 mg/kg day, and the average cumulative hazard index of fluoride was > 3.13 for all age groups. Water quality variations were observed in all conventional water treatment systems in the rainy season, and further research should focus on its optimization to safeguard the public.
Microbiological Status and Food Safety Compliance of Commercial Basil Production Systems.
de Bruin, Willeke; Otto, Denise; Korsten, Lise
2016-01-01
Basil has been implicated in a number of microbe-associated foodborne illnesses across the world, and the source of contamination has often been traced back to the production and/or processing stages of the supply chain. The aim of this study was to evaluate the microbiological quality of fresh basil from the point of production to the retail outlet in the Gauteng and Northwest Provinces of South Africa. A total of 463 samples were collected over a 3-month period from two large-scale commercial herb producing and processing companies and three retail outlets. The microbiological quality of the samples was assessed based on the presence or absence of Escherichia coli O157:H7 and Salmonella Typhimurium and the levels of the indicator bacteria E. coli and total coliforms. Salmonella Typhimurium was detected on four basil samples (0.9%) arriving at the processing facility and at dispatch, but no E. coli O157:H7 was detected throughout the study. Total coliform counts were 0.4 to 4.1 CFU/g for basil, 1.9 to 3.4 log CFU/ml for water, and 0.2 to 1.7 log CFU/cm(2) for contact surfaces, whereas E. coli was detected in the water samples and only once on basil. The Colilert-18 and membrane filter methods were used to analyze water samples, and a comparison of results revealed that the Colilert-18 method was more sensitive. Strong evidence suggests that high numbers of coliforms do not necessarily indicate the presence of Salmonella Typhimurium. The study results highlight the importance of effective implementation of food safety management systems in the fresh produce industry.
Ortega-Paredes, David; Barba, Pedro; Mena-López, Santiago; Espinel, Nathaly; Zurita, Jeannete
2018-04-30
Dissemination of Extended spectrum β-lactamases (ESBL) Enterobacteriaceae is a major medical threat. Vegetables and fruits, which are usually consumed raw, are a very suitable pathway for the spread of these bacteria from farm-to-fork. However, limited information exists regarding resistant bacteria and epidemic clones that are disseminated in vegetables and tap water in South America. We processed a total of 90 samples in triplicate of nine typically consumed raw vegetables from a central municipal market, and tap water samples were processed from twenty-one locations in Quito, Ecuador. The samples were analyzed for total coliforms and ESBL Enterobacteriaceae contamination using the dilution filtration method. ESBL Escherichia coli isolates were phenotypically and genotypically characterized. The water was free of Enterobacteriaceae, but all the vegetables and fruits (except for blackberries) presented total coliform counts. Watercress had the highest load of total coliforms (3.3 × 10E4). ESBL E. coli was detected in alfalfa, leaf lettuce and parsley/cilantro samples. Alfalfa had the highest load of ESBL E. coli/total coliforms (1/3.3 × 10E2). We identified E. coli ST44-A and ST410-A harboring bla CTX-M-15 downstream of ISEcp1. Alfalfa and parsley/cilantro were contaminated with hyperepidemic E. coli ST410-A, which was resistant to quinolones and harbored bla CTX-M-15 . For the first time, we report ESBL E. coli ST410-A from vegetables and express an alert regarding the health risk this could represent. Copyright © 2018 Elsevier B.V. All rights reserved.
Dankovich, Theresa A.; Levine, Jonathan S.; Potgieter, Natasha; Dillingham, Rebecca; Smith, James A.
2016-01-01
There is an urgent need for inexpensive point-of-use methods to purify drinking water in developing countries to reduce the incidence of illnesses caused by waterborne pathogens. Previously, our work showed the deactivation of laboratory-cultured bacteria by percolation through a thick paper sheet containing either silver (Ag) or copper (Cu) nanoparticles (NP). In this study, these paper filters containing AgNPs or CuNPs have been tested with water sourced from contaminated streams in Limpopo, South Africa. Following the percolation of the contaminated stream water through the metal nanoparticle (MNP) papers, the water quality of the filtered effluent was evaluated with respect to the colony counts of total coliform and E. coli bacteria, turbidity, and either silver or copper ions. Influent total coliform bacteria concentrations from the stream water in Limpopo ranged from 250 CFU/100 mL to 1,750,000 CFU/100 mL. With the less contaminated stream water (250 - 15,000 CFU/100 mL), both AgNP and CuNP papers showed complete inactivation of the coliform bacteria. With the surface water with higher coliform bacteria levels (500,000 - 1,000,000 CFU/100 mL), both the AgNP and CuNP papers showed similar results with a slightly higher bacteria reduction of log10 5.1 for the AgNP papers than the log10 4.8 reduction for the CuNP papers. E. coli results followed similar trends. For most water purification experiments, the metal release from the sheets was minimal, with values under 0.1 ppm for Ag and 1.0 ppm for Cu (the current US EPA and WHO drinking water limits for Ag and Cu, respectively). These results show good potential for the use of paper embedded with silver and/or copper nanoparticles as effective point-of-use water purifiers. PMID:27022474
Shibata, Tomoyuki; Solo-Gabriele, Helena M.; Fleming, Lora E.; Elmir, Samir
2008-01-01
The microbial water quality at two beaches, Hobie Beach and Crandon Beach, in Miami-Dade County, Florida, USA was measured using multiple microbial indicators for the purpose of evaluating correlations between microbes and for identifying possible sources of contamination. The indicator microbes chosen for this study (enterococci, Escherichia coli, fecal coliform, total coliform and C. perfringens) were evaluated through three different sampling efforts. These efforts included daily measurements at four locations during a wet season month and a dry season month, spatially intensive water sampling during low- and high-tide periods, and a sand sampling effort. Results indicated that concentrations did not vary in a consistent fashion between one indicator microbe and another. Daily water quality frequently exceeded guideline levels at Hobie Beach for all indicator microbes except for fecal coliform, which never exceeded the guideline. Except for total coliform, the concentrations of microbes did not change significantly between seasons in spite of the fact that the physical–chemical parameters (rainfall, temperature, pH, and salinity) changed significantly between the two monitoring periods. Spatially intense water sampling showed that the concentrations of microbes were significantly different with distance from the shoreline. The highest concentrations were observed at shoreline points and decreased at offshore points. Furthermore, the highest concentrations of indicator microbe concentrations were observed at high tide, when the wash zone area of the beach was submerged. Beach sands within the wash zone tested positive for all indicator microbes, thereby suggesting that this zone may serve as the source of indicator microbes. Ultimate sources of indicator microbes to this zone may include humans, animals, and possibly the survival and regrowth of indicator microbes due to the unique environmental conditions found within this zone. Overall, the results of this study indicated that the concentrations of indicator microbes do not necessarily correlate with one another. Exceedence of water quality guidelines, and thus the frequency of beach advisories, depends upon which indicator microbe is chosen. PMID:15261551
Fatemeh, Dehghan; Reza, Zolfaghari Mohammad; Mohammad, Arjomandzadegan; Salomeh, Kalantari; Reza, Ahmari Gholam; Hossein, Sarmadian; Maryam, Sadrnia; Azam, Ahmadi; Mana, Shojapoor; Negin, Najarian; Reza, Kasravi Alii; Saeed, Falahat
2014-01-01
Objective To analyse molecular detection of coliforms and shorten the time of PCR. Methods Rapid detection of coliforms by amplification of lacZ and uidA genes in a multiplex PCR reaction was designed and performed in comparison with most probably number (MPN) method for 16 artificial and 101 field samples. The molecular method was also conducted on isolated coliforms from positive MPN samples; standard sample for verification of microbial method certificated reference material; isolated strains from certificated reference material and standard bacteria. The PCR and electrophoresis parameters were changed for reducing the operation time. Results Results of PCR for lacZ and uidA genes were similar in all of standard, operational and artificial samples and showed the 876 bp and 147 bp bands of lacZ and uidA genes by multiplex PCR. PCR results were confirmed by MPN culture method by sensitivity 86% (95% CI: 0.71-0.93). Also the total execution time, with a successful change of factors, was reduced to less than two and a half hour. Conclusions Multiplex PCR method with shortened operation time was used for the simultaneous detection of total coliforms and Escherichia coli in distribution system of Arak city. It's recommended to be used at least as an initial screening test, and then the positive samples could be randomly tested by MPN. PMID:25182727
NASA Astrophysics Data System (ADS)
Promping, J.; Prakongsil, P.; Picha, R.; Traikool, T.
2017-09-01
This research is designed to determine the efficacy of DBD plasma to reduce the microbial contamination of pepper and sesame powder. The AC high voltage power supply was used with voltages of up to 20 kV and the frequency of 5.5 kHz was applied to the DBD. The gap of DBD electrodes was set at 5 mm. In raw initial samples, the total aerobic count of pepper (Piper nigrum) was found at quite a high level at 5.40 × 105 CFU/g. Coliform bacteria was also found in both the sesame (Sesamum indicum Linn.) powder and pepper (Piper nigrum) powder. Both kinds of samples were treated with plasma for 2, 4, 6 and 10 minutes. Results indicated that plasma treatment at 2-10 minutes reduced the total aerobic count of pepper allowed to achieve the acceptable microbial level for spices. The plasma treatment times in this experiment were also effective in reducing faecal coliform bacteria in both pepper and sesame powders (MPN/g <3) as indicated in the standard. Plasma from dielectric barrier charge can reduce Staphylococcus epidermidis in sesame powder which was artificially contaminated with 3.50 × 102 CFU/g resulting in 0.15-0.5 log cycle reductions of microbial load.
Alqahtani, Jobran M; Asaad, Ahmed M; Ahmed, Essam M; Qureshi, Mohamed A
2015-01-01
The aim was to investigate the bacteriological quality of drinking water, and explore the factors involved in the knowledge of the public about the quality of drinking water in Najran region, Saudi Arabia. A cross-sectional descriptive study. A total of 160 water samples were collected. Total coliforms, fecal coliform, and fecal streptococci were counted using Most Probable Number method. The bacterial genes lacZ and uidA specific to total coliforms and Escherichia coli, respectively, were detected using multiplex polymerase chain reaction. An interview was conducted with 1200 residents using a questionnaire. Total coliforms were detected in 8 (20%) of 40 samples from wells, 13 (32.5%) of 40 samples from tankers, and 55 (68.8%) of 80 samples from roof tanks. Twenty (25%) and 8 (10%) samples from roof tanks were positive for E. coli and Streptococcus faecalis, respectively. Of the 1200 residents participating in the study, 10%, 45.5%, and 44.5% claimed that they depended on municipal water, bottled water, and well water, respectively. The majority (95.5%) reported the use of roof water tanks as a source of water supply in their homes. Most people (80%) believed that drinking water transmitted diseases. However, only 25% of them participated in educational programs on the effect of polluted water on health. Our results could help health authorities consider a proper regular monitoring program and a sustainable continuous assessment of the quality of well water. In addition, this study highlights the importance of the awareness and educational programs for residents on the effect of polluted water on public health.
McGinnis, Shannon; Spencer, Susan K.; Firnstahl, Aaron; Stokdyk, Joel; Borchardt, Mark A.; McCarthy, David; Murphy, Heather
2018-01-01
Combined sewer overflows (CSOs) are a known source of human fecal pollution and human pathogens in urban water bodies, which may present a significant public health threat. To monitor human fecal contamination in water, bacterial fecal indicator organisms (FIOs) are traditionally used. However, because FIOs are not specific to human sources and do not correlate with human pathogens, alternative fecal indicators detected using qPCR are becoming of interest to policymakers. For this reason, this study measured correlations between the number and duration of CSOs and mm of rainfall, concentrations of traditional FIOs and alternative indicators, and the presence of human pathogens in two urban creeks. Samples were collected May–July 2016 and analyzed for concentrations of FIOs (total coliforms and E. coli) using membrane filtration as well as for three alternative fecal indicators (human Bacteroides HF183 marker, human polyomavirus (HPoV), pepper mild mottle virus (PMMoV)) and nine human pathogens using qPCR. Four of the nine pathogens analyzed were detected at these sites including adenovirus, Enterohemorrhagic E. coli, norovirus, and Salmonella. Among all indicators studied, human Bacteroides and total coliforms were significantly correlated with recent CSO and rainfall events, while E. coli, PMMoV, and HPoV did not show consistent significant correlations. Further, human Bacteroides were a more specific indicator, while total coliforms were a more sensitive indicator of CSO and rainfall events. Results may have implications for the use and interpretation of these indicators in future policy or monitoring programs.
McGinnis, Shannon; Spencer, Susan; Firnstahl, Aaron; Stokdyk, Joel; Borchardt, Mark; McCarthy, David T; Murphy, Heather M
2018-07-15
Combined sewer overflows (CSOs) are a known source of human fecal pollution and human pathogens in urban water bodies, which may present a significant public health threat. To monitor human fecal contamination in water, bacterial fecal indicator organisms (FIOs) are traditionally used. However, because FIOs are not specific to human sources and do not correlate with human pathogens, alternative fecal indicators detected using qPCR are becoming of interest to policymakers. For this reason, this study measured correlations between the number and duration of CSOs and mm of rainfall, concentrations of traditional FIOs and alternative indicators, and the presence of human pathogens in two urban creeks. Samples were collected May-July 2016 and analyzed for concentrations of FIOs (total coliforms and E. coli) using membrane filtration as well as for three alternative fecal indicators (human Bacteroides HF183 marker, human polyomavirus (HPoV), pepper mild mottle virus (PMMoV)) and nine human pathogens using qPCR. Four of the nine pathogens analyzed were detected at these sites including adenovirus, Enterohemorrhagic E. coli, norovirus, and Salmonella. Among all indicators studied, human Bacteroides and total coliforms were significantly correlated with recent CSO and rainfall events, while E. coli, PMMoV, and HPoV did not show consistent significant correlations. Further, human Bacteroides were a more specific indicator, while total coliforms were a more sensitive indicator of CSO and rainfall events. Results may have implications for the use and interpretation of these indicators in future policy or monitoring programs. Copyright © 2018 Elsevier B.V. All rights reserved.
Sivaraman, G K; Visnuvinayagam, S; Jha, Ashish Kumar; Renuka, V; Remya, S; Vanik, Deesha
2016-07-01
The present study was carried out to assess the microbial quality of fish processing industries effluent at Bhidia bar-mouth, Veraval, Gujarat during April, 2012 to March 2013. The total viable bacterial count (TVBC), total Enterobacteriaceae count, E. coli count (EC), Staphylococcus aureus and Fecal Streptococcal count in effluent ranged from 3.0 x 10(-1) to 6.8 x 10(6), 9.0 x 10(1) to 2.9 x 10(4), 0 to 0. 5 x 10(4), 0 to 0. 4 x 102 and 0.3 x 10(1) to 0. 1 x 10(4) cfu.(-1)respectively. Significantly higher load of TEC, E. coli, S.aureus, Fecal Streptococci, Total coliforms and Fecal coliforms were higher during summer whereas, TVBC was higher in the month of Sept.-Oct. Furthermore, the total coliform and fecal coliform counts were found to be higher with 1400+ /100 ml MPN value throughout the year of the study, except in the month of August. Overall occurrence of pathogenic strains of E. coli, S. aureus and Fecal streptococci were 41.67%, 25.00% and 66.67% respectively during this period. The antibiogram of the isolated E. coli isolates show that almost 50% were resistant to Cefazidime/Clavulanic acid (CAC), Amoxyclav (AMC), Ciprofloxacin (CIF) and Ampicillin (AMP). The present study indicated that the effluent of fish processing industry was heavily contaminated with E. coli, S. aureus and Fecal Streptococci which confirmed improper treatment of fish processing effluent. Moreover, the precedence of antibiotic resistant E. coli may pose threat to public health safety.
Potential sources of microbial contamination in unpasteurized apple cider.
Garcia, Luis; Henderson, John; Fabri, Martha; Oke, Moustapha
2006-01-01
A study was conducted to identify possible sources of microbial contamination and to assess the effect of good cleaning and sanitation practices on the microbial quality and safety of unpasteurized apple cider. Raw unwashed apples, washed apples, cleaning water, fresh cider, and finished cider samples were collected from five Ontario producers over 4 months and microbiologically tested. Total coliforms were found in 31, 71 and 38% of the unwashed apple, water, and washed apple samples, respectively. Escherichia coli was found in 40% of the water samples from one producer alone. The washing step was identified as a potential source of contamination, possibly due to water in the dump tanks seldom being refreshed, and because scrubbers, spray nozzles, and conveyors were not properly cleaned and sanitized. Higher total coliform counts (P < 0.0001) and prevalence (P < 0.0001) in fresh cider compared with those in unwashed apples and washed apples indicated considerable microbial buildup along the process, possibly explained by the lack of appropriate equipment sanitation procedures. Results showed that producers who had better sanitary practices in place had lower (P < 0.001) total coliform prevalence than the rest of the producers. Overall results show that good sanitation procedures are associated with improved microbial quality of fresh cider in terms of total coliforms and that operators who pasteurize and/or UV treat their product should still be required to have a sound good manufacturing practices program in place to prevent recontamination. Cryptosporidium parvum, an important pathogen for this industry, was found in different sample types, including washed apples, water, and fresh and finished cider.
Tobin, R S; Lomax, P; Kushner, D J
1980-01-01
Nine different brands of membrane filter were compared in the membrane filtration (MF) method, and those with the highest yields were compared against the most-probable-number (MPN) multiple-tube method for total coliform enumeration in simulated sewage-contaminated tap water. The water was chlorinated for 30 min to subject the organisms to stresses similar to those encountered during treatment and distribution of drinking water. Significant differences were observed among membranes in four of the six experiments, with two- to four-times-higher recoveries between the membranes at each extreme of recovery. When results from the membranes with the highest total coliform recovery rate were compared with the MPN results, the MF results were found significantly higher in one experiment and equivalent to the MPN results in the other five experiments. A comparison was made of the species enumerated by these methods; in general the two methods enumerated a similar spectrum of organisms, with some indication that the MF method was subject to greater interference by Aeromonas. PMID:7469407
Removal of contaminants and pathogens from secondary effluents using intermittent sand filters.
Bali, Mahmoud; Gueddari, Moncef; Boukchina, Rachid
2011-01-01
Intermittent infiltration percolation of wastewater through unsaturated sand bed is an extensive treatment technique aimed at eliminating organic matter, oxidizing ammonium and removing pathogens. The main purpose of this study was to determine the depuration efficiencies of a sand filter to remove contaminants from secondary wastewater effluents. Elimination of pathogenic bacteria (total and faecal coliforms, streptococci) and their relationship with the filter depth were investigated. Results showed a high capacity of infiltration percolation process to treat secondary effluents. Total elimination of suspended solids was obtained. Mean removal rate of BOD(5) and COD was more than 97 and more than 81%, respectively. Other water quality parameters such as NH(4)-N, TKN and PO(4)-P showed significant reduction except NO(3)-N which increased significantly in the filtered water. Efficiency of pathogenic bacteria removal was shown to mainly depend on the filter depth. Average reductions of 2.35 log total coliforms, 2.47 log faecal coliforms and 2.11 log faecal streptococci were obtained. The experimental study has shown the influence of the temperature on the output purification of infiltration percolation process.
Occurrence and distribution of microbiological indicators in groundwater and stream water
Francy, D.S.; Helsel, D.R.; Nally, R.A.
2000-01-01
A total of 136 stream water and 143 groundwater samples collected in five important hydrologic systems of the United States were analyzed for microbiological indicators to test monitoring concepts in a nationally consistent program. Total coliforms were found in 99%, Escherichia coli in 97%, and Clostridium perfringens in 73% of stream water samples analyzed for each bacterium. Total coliforms were found in 20%, E. coli in less than 1%, and C. perfringens in none of the groundwater samples analyzed for each bacterium. Although coliphage analyses were performed on many of the samples, contamination in the laboratory and problems discerning discrete plaques precluded quantification. Land use was found to have the most significant effect on concentrations of bacterial indicators in stream water. Presence of septic systems on the property near the sampling site and well depth were found to be related to detection of coliforms in groundwater, although these relationships were not statistically significant. A greater diversity of sites, more detailed information about some factors, and a larger dataset may provide further insight to factors that affect microbiological indicators.
Duggan, J; Bates, M P; Phillips, C A
2001-06-01
The use of poultry waste as a fertiliser on arable land is an accepted method of waste treatment. However, run-off from such practices may result in contamination of the watercourse by human pathogens. In this study the effectiveness of using constructed wetlands as an alternative treatment for poultry manure waste was evaluated. Enumeration of Campylobacter spp., Escherichia coli, total coliforms and total aerobes were carried out on influent and effluent samples from reed beds loaded with poultry waste. For both sequential loading and continuous loading there was a statistically significant mean log reduction of 3.56 and 4.25 for E. coli, 3.2 and 3.88 for coliforms, 3.85 and 4.2 for total aerobic counts and 3.13 and 2.96 for Campylobacter spp., respectively. This method, which has been previously recognised as cost-effective and environmentally acceptable, provides an efficient method for reducing numbers of these bacteria in poultry waste and therefore an effective alternative treatment for such waste or waters containing run off from land previously spread with poultry manure.
Assessing market-sold remedies in lomé (togo) for hygienic quality.
de Souza, Comlan; Ameyapoh, Yaovi; Karou, Simplice D; Anani, Kokou T; Kpodar, Madje L; Gbeassor, Mensavi
2011-01-01
Traditional concoctions sold in marketplaces are always assumed to be safe and efficient; however, they can be potentially toxic because of poor hygienic practices in plant processing or storage. The present study aimed to assess for the microbial quality of market-sold vegetable drugs in Lomé. Thus, a total of 209 plant remedies were collected in marketplaces and analysed for the presence of total aerobic bacteria, total coliforms, thermotolerant coliforms, Staphylococcus aureus, sulphite reducing bacteria, and yeast and moulds according to the French Association of Normalisation (AFNOR) guidelines. The results revealed that all formulations were contaminated by several microorganisms, excepted alcohol-based mixtures. According to AFNOR limits nonconform drugs were according to total aerobic bacteria (86.96% powders, 81.82% capsules, 66.67% tisanes, and 42.11% decoctions); to total coliforms (9.10% capsules, 8.70% powders and 1.75% decoction); to yeasts and moulds (77.78% ointments, 40% calcined powders, 36.36% capsules, and 23.91% powders). The microbiological analysis revealed that the majority of contaminating bacteria were gram positive catalase positive and oxidase positive bacilli. Quality control studies on market-sold remedies are currently needed to evaluate the microbial risk in consuming these products and they may allow the standardisation of plant processing and storage.
Assessing Market-Sold Remedies in Lomé (Togo) for Hygienic Quality
de Souza, Comlan; Ameyapoh, Yaovi; Karou, Simplice D.; Anani, Kokou T.; Kpodar, Madje L.; Gbeassor, Mensavi
2011-01-01
Traditional concoctions sold in marketplaces are always assumed to be safe and efficient; however, they can be potentially toxic because of poor hygienic practices in plant processing or storage. The present study aimed to assess for the microbial quality of market-sold vegetable drugs in Lomé. Thus, a total of 209 plant remedies were collected in marketplaces and analysed for the presence of total aerobic bacteria, total coliforms, thermotolerant coliforms, Staphylococcus aureus, sulphite reducing bacteria, and yeast and moulds according to the French Association of Normalisation (AFNOR) guidelines. The results revealed that all formulations were contaminated by several microorganisms, excepted alcohol-based mixtures. According to AFNOR limits nonconform drugs were according to total aerobic bacteria (86.96% powders, 81.82% capsules, 66.67% tisanes, and 42.11% decoctions); to total coliforms (9.10% capsules, 8.70% powders and 1.75% decoction); to yeasts and moulds (77.78% ointments, 40% calcined powders, 36.36% capsules, and 23.91% powders). The microbiological analysis revealed that the majority of contaminating bacteria were gram positive catalase positive and oxidase positive bacilli. Quality control studies on market-sold remedies are currently needed to evaluate the microbial risk in consuming these products and they may allow the standardisation of plant processing and storage. PMID:21350662
Niemi, R M; Heikkilä, M P; Lahti, K; Kalso, S; Niemelä, S I
2001-06-01
Enumeration of coliform bacteria and Escherichia coli is the most widely used method in the estimation of hygienic quality of drinking water. The yield of target bacteria and the species composition of different populations of coliform bacteria may depend on the method.Three methods were compared. Three membrane filtration methods were used for the enumeration of coliform bacteria in shallow well waters. The yield of confirmed coliform bacteria was highest on Differential Coliform agar, followed by LES Endo agar. Differential Coliform agar had the highest proportion of typical colonies, of which 74% were confirmed as belonging to the Enterobacteriaceae. Of the typical colonies on Lactose Tergitol 7 TTC agar, 75% were confirmed as Enterobacteriaceae, whereas 92% of typical colonies on LES Endo agar belonged to the Enterobacteriaceae. LES Endo agar yielded many Serratia strains, Lactose Tergitol 7 TTC agar yielded numerous strains of Rahnella aquatilis and Enterobacter, whereas Differential Coliform agar yielded the widest range of species. The yield of coliform bacteria varied between methods. Each method compared had a characteristic species distribution of target bacteria and a typical level of interference of non-target bacteria. Identification with routine physiological tests to distinct species was hampered by the slight differences between species. High yield and sufficient selectivity are difficult to achieve simultaneously, especially if the target group is diverse. The results showed that several aspects of method performance should be considered, and that the target group must be distinctly defined to enable method comparisons.
Del Piano, Mario; Pagliarulo, Michela; Tari, Roberto; Carmagnola, Stefania; Balzarini, Marco; Lorenzini, Paola; Pane, Marco
2014-01-01
The inhibition of physiological gastric acid secretion induced by proton pump inhibitors (PPIs), the most widely used drugs in the world, may cause a significant bacterial overgrowth in the gastrointestinal tract as a side effect. This study was undertaken firstly to correlate PPI intake with concentration of specific bacterial groups in the stomach as well as possible Helicobacter pylori infection, and secondly to assess the efficacy of the 4 lactobacilli L. rhamnosus LR06 (DSM 21981), L. pentosus LPS01 (DSM 21980), L. plantarum LP01 (LMG P-21021), and L. delbrueckii subsp. delbrueckii LDD01 (DSM 22106) in the restoration of a physiological gastric barrier. Total bacteria, sulphite-reducing bacteria (SRB), total coliforms, and total lactobacilli were quantified in samples of gastric juice from 29 subjects taking PPIs for at least 3 months compared with 36 control subjects. The presence of H. pylori was also assessed.The subjects treated with PPIs with a concentration of total bacteria in the gastric juice higher than 10(5) cells/mL were selected for an intervention study with the 4 lactobacilli L. rhamnosus LR06, L. pentosus LPS01, L. plantarum LP01, and L. delbrueckii subsp. delbrueckii LDD01. After 15 days of supplementation, the same bacterial groups were quantified to compare these values with the baseline. No significant correlation was found between the presence of H. pylori and PPI intake. The baseline quantification of bacterial groups (log10 CFU/mL of gastric juice, PPI group vs. control) showed: total bacteria 8.35 versus 3.95 (P<0.001); total coliforms 4.98 versus 2.35 (P<0.001); SRB 5.71 versus 2.28 (P=0.065); and total lactobacilli 3.85 versus 2.20 (P=0.005). After 15 days of treatment with the 4 lactobacilli, the quantification of bacterial groups gave the following results: total bacteria 7.91 versus 8.35 at time zero (P=0.002); total coliforms 4.21 versus 4.98 at time zero (P<0.001); SRB 4.94 versus 5.71 at baseline (P=0.060); and total lactobacilli 7.20 versus 3.85 at baseline (P=0.040). A significant impairment of intragastric acidity is sufficient to induce a relevant bacterial overgrowth, with particular reference to SRB and total coliforms. This fact can contribute to an increase in the risk of infections and intestinal diseases. It could be crucial to restore the physiological "gastric barrier." The 2-week supplementation with the 4 lactobacilli tested proved to be effective in significantly reducing total bacteria and coliforms in the gastric milieu in subjects chronically treated with PPIs. It is therefore possible to hopothesise a beneficial role for such lactobacilli in clinical practice.
Enumeration of Escherichia coli O157:H7 in Outbreak-Associated Beef Patties.
Gill, Alexander; Huszczynski, George
2016-07-01
An outbreak of five cases of Escherichia coli O157 infection that occurred in Canada in 2012 was linked to frozen beef patties seasoned with garlic and peppercorn. Unopened retail packs of beef patties from the implicated production lot were recovered and analyzed to enumerate E. coli O157, other E. coli strains, and total coliforms. E. coli O157 was not recovered by direct enumeration on selective agar media. E. coli O157 in the samples was estimated at 3.1 most probable number per 140 g of beef patty, other E. coli was 11 CFU/g, and coliforms were 120 CFU/g. These results indicate that the presence of E. coli O157 in ground beef at levels below 0.1 CFU/g may cause outbreaks. However, the roles of temperature abuse, undercooking, and crosscontamination in amplifying the risk are unknown.
Description and field test of an in situ coliform monitoring system
NASA Technical Reports Server (NTRS)
Grana, D. C.; Wilkins, J. R.
1979-01-01
A prototype in situ system for monitoring the levels of fecal coliforms in shallow water bodies was developed and evaluated. This system was based on the known relationship between the concentration of the coliform bacteria and the amount of hydrogen they produce during growth in a complex organic media. The prototype system consists of a sampler platform, which sits on the bottom; a surface buoy, which transmits sampler-generated data; and a shore station, which receives, displays the data, and controls the sampler. The concept of remote monitoring of fecal coliform concentrations by utilizing a system based on the electrochemical method was verified during the evaluation of the prototype.
AlOtaibi, Eed L Sh
2009-03-21
Urban water sources of Khamis Mushait Governorate, southwestern Saudi Arabia, were studied to assess their bacteriological characteristics and suitability for potable purposes. A cross-sectional epidemiological method was adopted to investigate the four main urban water sources (i.e. bottled, desalinated, surface, and well water). These were sampled and examined between February and June 2007. A total of 95 water samples from bottled, desalinated, surface, and well water were collected randomly from the study area using different gathering and analysing techniques. The bacteriological examination of water samples included the most probable number of presumptive coliforms, faecal coliforms, and faecal streptococci (MPN/100 ml). The results showed that the total coliform count (MPN/100 ml) was not detected in any samples taken from bottled water, while it was detected in those taken from desalinated, surface, and well water: percentages were 12.9, 80.0, and 100.0, respectively. Faecal coliforms were detected in desalinated, surface, and well water, with percentages of 3.23, 60.0 and 87.88, respectively. About 6.45% of desalinated water, 53.33% of surface water, and 57.58% of well water was found positive for faecal streptococci. Colonies of coliforms were identified in different micro-organisms with various percentages. Water derived from traditional sources (wells) showed increases in most of the investigated bacteriological parameters, followed by surface water as compared to bottled or desalinated water. This may be attributed to the fact that well and surface water are at risk of contamination as indicated by the higher levels of most bacteriological parameters. Moreover, well water is exposed to point sources of pollution such as septic wells and domestic and farming effluents, as well as to soil with a high humus content. The lower bacteriological characteristics in samples from bottled water indicate that it is satisfactory for human drinking purposes. Contamination of desalinated water that is the main urban water source may occur during transportation from the desalination plant or in the house reservoir of the consumer. Improving and expanding the existing water treatment and sanitation systems is more likely to provide safe and sustainable sources of water over the long term. Strict hygienic measures should be applied to improve water quality and to avoid deleterious effects on public health, by using periodical monitoring programmes to detect sewage pollution running over local hydrological networks and valleys.
Sh AlOtaibi, Eed L
2009-01-01
Background Urban water sources of Khamis Mushait Governorate, southwestern Saudi Arabia, were studied to assess their bacteriological characteristics and suitability for potable purposes. A cross-sectional epidemiological method was adopted to investigate the four main urban water sources (i.e. bottled, desalinated, surface, and well water). These were sampled and examined between February and June 2007. Results A total of 95 water samples from bottled, desalinated, surface, and well water were collected randomly from the study area using different gathering and analysing techniques. The bacteriological examination of water samples included the most probable number of presumptive coliforms, faecal coliforms, and faecal streptococci (MPN/100 ml). The results showed that the total coliform count (MPN/100 ml) was not detected in any samples taken from bottled water, while it was detected in those taken from desalinated, surface, and well water: percentages were 12.9, 80.0, and 100.0, respectively. Faecal coliforms were detected in desalinated, surface, and well water, with percentages of 3.23, 60.0 and 87.88, respectively. About 6.45% of desalinated water, 53.33% of surface water, and 57.58% of well water was found positive for faecal streptococci. Colonies of coliforms were identified in different micro-organisms with various percentages. Conclusion Water derived from traditional sources (wells) showed increases in most of the investigated bacteriological parameters, followed by surface water as compared to bottled or desalinated water. This may be attributed to the fact that well and surface water are at risk of contamination as indicated by the higher levels of most bacteriological parameters. Moreover, well water is exposed to point sources of pollution such as septic wells and domestic and farming effluents, as well as to soil with a high humus content. The lower bacteriological characteristics in samples from bottled water indicate that it is satisfactory for human drinking purposes. Contamination of desalinated water that is the main urban water source may occur during transportation from the desalination plant or in the house reservoir of the consumer. Improving and expanding the existing water treatment and sanitation systems is more likely to provide safe and sustainable sources of water over the long term. Strict hygienic measures should be applied to improve water quality and to avoid deleterious effects on public health, by using periodical monitoring programmes to detect sewage pollution running over local hydrological networks and valleys. PMID:19302710
Masiello, S N; Martin, N H; Trmčić, A; Wiedmann, M; Boor, K J
2016-01-01
The presence of coliform bacteria in pasteurized fluid milk typically indicates that product contamination occurred downstream of the pasteurizer, but it may also indicate pasteurization failure. Although coliform detection is frequently used as a hygiene indicator for dairy products, our understanding of the taxonomic and phenotypic coliform diversity associated with dairy products is surprisingly limited. Therefore, using Petrifilm Coliform Count plates (3M, St. Paul, MN), we isolated coliforms from high-temperature, short-time (HTST)-pasteurized fluid milk samples from 21 fluid milk processing plants in the northeast United States. Based on source information and initial characterization using partial 16S rDNA sequencing, 240 nonredundant isolates were obtained. The majority of these isolates were identified as belonging to the genera Enterobacter (42% of isolates), Hafnia (13%), Citrobacter (12%), Serratia (10%), and Raoultella (9%); additional isolates were classified into the genera Buttiauxella, Cedecea, Kluyvera, Leclercia, Pantoea, and Rahnella. A subset of 104 representative isolates was subsequently characterized phenotypically. Cold growth analysis in skim milk broth showed that all isolates displayed at least a 2-log increase over 10 d at 6°C; the majority of isolates (n=74) displayed more than a 5-log increase. In total, 43% of the representative isolates displayed lipolysis when incubated on spirit blue agar at 6°C for 14 d, whereas 71% of isolates displayed proteolysis when incubated on skim milk agar at 6°C for 14 d. Our data indicate that a considerable diversity of coliforms is found in HTST-pasteurized fluid milk and that a considerable proportion of these coliforms have phenotypic characteristics that will allow them to cause fluid milk spoilage. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Suzuki, Yoshihiro; Niina, Kouki; Matsuwaki, Tomonori; Nukazawa, Kei; Iguchi, Atsushi
2018-01-28
The aim of this study was to rapidly and effectively analyze coliforms, which are the most fundamental indicators of water quality for fecal pollution, using matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS). Coliform bacteria were isolated from municipal sewage, river water, and groundwater. For each sample, 100 isolates were determined by MALDI-TOF MS. In addition, these same 100 isolates were also identified via 16S rRNA gene sequence analysis. Obtained MALDI-TOF MS data were compared with the 16S rRNA sequencing analysis, and the validity of MALDI-TOF MS for classification of coliform bacteria was examined. The concordance rate of bacterial identification for the 100 isolates obtained by MALDI-TOF MS analysis and 16S rRNA gene sequence analysis for sewage, river water, and ground water were 96%, 74%, and 62% at the genus level, respectively. Among the sewage, river water, and ground water samples, the coliform bacterial flora were distinct. The dominant genus of coliforms in sewage, river water, and groundwater were Klebsiella spp., Enterobacter spp., and Serratia spp., respectively. We determined that MALDI-TOF MS is a rapid and accurate tool that can be used to identify coliforms. Therefore, without using conventional 16S rRNA sequencing, it is possible to rapidly and effectively classify coliforms in water using MALDI-TOF MS.
Specificity of coliphages in evaluating marker efficacy: a new insight for water quality indicators.
Mookerjee, Subham; Batabyal, Prasenjit; Halder, Madhumanti; Palit, Anup
2014-11-01
Conventional procedures for qualitative assessment of coliphage are time consuming multiple step approach for achieving results. A modified and rapid technique has been introduced for determination of coliphage contamination among potable water sources during water borne outbreaks. During December 2013, 40 water samples from different potable water sources, were received for water quality analyses, from a jaundice affected Municipality of West Bengal, India. Altogether, 30% water samples were contaminated with coliform (1-20 cfu/ml) and 5% with E. coli (2-5 cfu/ml). Among post-outbreak samples, preponderance of coliform has decreased (1-4 cfu/ml) with total absence of E. coli. While standard technique has detected 55% outbreak samples with coliphage contamination, modified technique revealed that 80%, double than that of bacteriological identification rate, were contaminated with coliphages (4-20 pfu/10 ml). However, post-outbreak samples were detected with 1-5 pfu/10 ml coliphages among 20% samples. Coliphage detection rate through modified technique was nearly double (50%) than that of standard technique (27.5%). In few samples (with coliform load of 10-100 cfu/ml), while modified technique could detect coliphages among six samples (10-20 pfu/10 ml), standard protocol failed to detect coliphage in any of them. An easy, rapid and accurate modified technique has thereby been implemented for coliphage assessment from water samples. Coliform free water does not always signify pathogen free potable water and it is demonstrated that coliphage is a more reliable 'biomarker' to ascertain contamination level in potable water. Copyright © 2014 Elsevier B.V. All rights reserved.
Maintenance Dredging of the Federal Navigation Channels in the Detroit River, Michigan.
1976-01-01
which remained constant. 2.32 Total phosphorus concentrations have decreased at all milepoints since 1968 with the most significant change noted at 8.7W...the downriver region. The most important results were observed with respect to the phosphorus concentration which has decreased significantly at nearly...The chloride, phenol, phosphorus , and iron concentrations have all decreased. The past four years have shown signs that the coliform levels may be
2011-01-01
Background Infantile colic is a common disturb within the first 3 months of life, nevertheless the pathogenesis is incompletely understood and treatment remains an open issue. Intestinal gas production is thought to be one of the causes of abdominal discomfort in infants suffering from colic. However, data about the role of the amount of gas produced by infants' colonic microbiota and the correlation with the onset of colic symptoms are scanty. The benefit of supplementation with lactobacilli been recently reported but the mechanisms by which they exert their effects have not yet been fully defined. This study was performed to evaluate the interaction between Lactobacillus spp. strains and gas-forming coliforms isolated from stools of colicky infants. Results Strains of coliforms were isolated from stools of 45 colicky and 42 control breastfed infants in McConkey Agar and identified using PCR with species-specific primers, and the BBL™ Enterotube™ II system for Enterobacteriaceae. Gas-forming capability of coliforms was assessed in liquid cultures containing lactose as sole carbon source. The average count of total coliforms in colicky infants was significantly higher than controls: 5.98 (2.00-8.76) log10 vs 3.90 (2.50-7.10) CFU/g of faeces (p = 0.015). The following strains were identified: Escherichia coli, Klebsiella pneumoniae, Klebsiella oxytoca, Enterobacter aerogenes, Enterobacter cloacae and Enterococcus faecalis. Then, 27 Lactobacillus strains were tested for their antagonistic effect against coliforms both by halo-forming method and in liquid co-cultures. Lactobacillus delbrueckii subsp.delbrueckii DSM 20074 and L. plantarum MB 456 were able to inhibit all coliforms strains (halo-forming method), also in liquid co-cultures, thus demonstrating an antagonistic activity. Conclusions This study shows that two out of 27 strains of Lactobacillus examined possess an antimicrobial effect against six species of gas-forming coliforms isolated from colicky infants. Our findings may stimulate new researches to identify which Lactobacillus strains can improve colicky symptoms by acting on coliforms gut colonization. PMID:21718486
Savino, Francesco; Cordisco, Lisa; Tarasco, Valentina; Locatelli, Emanuela; Di Gioia, Diana; Oggero, Roberto; Matteuzzi, Diego
2011-06-30
Infantile colic is a common disturb within the first 3 months of life, nevertheless the pathogenesis is incompletely understood and treatment remains an open issue. Intestinal gas production is thought to be one of the causes of abdominal discomfort in infants suffering from colic. However, data about the role of the amount of gas produced by infants' colonic microbiota and the correlation with the onset of colic symptoms are scanty. The benefit of supplementation with lactobacilli been recently reported but the mechanisms by which they exert their effects have not yet been fully defined. This study was performed to evaluate the interaction between Lactobacillus spp. strains and gas-forming coliforms isolated from stools of colicky infants. Strains of coliforms were isolated from stools of 45 colicky and 42 control breastfed infants in McConkey Agar and identified using PCR with species-specific primers, and the BBL™ Enterotube™ II system for Enterobacteriaceae. Gas-forming capability of coliforms was assessed in liquid cultures containing lactose as sole carbon source. The average count of total coliforms in colicky infants was significantly higher than controls: 5.98 (2.00-8.76) log10 vs 3.90 (2.50-7.10) CFU/g of faeces (p = 0.015). The following strains were identified: Escherichia coli, Klebsiella pneumoniae, Klebsiella oxytoca, Enterobacter aerogenes, Enterobacter cloacae and Enterococcus faecalis. Then, 27 Lactobacillus strains were tested for their antagonistic effect against coliforms both by halo-forming method and in liquid co-cultures. Lactobacillus delbrueckii subsp. delbrueckii DSM 20074 and L. plantarum MB 456 were able to inhibit all coliforms strains (halo-forming method), also in liquid co-cultures, thus demonstrating an antagonistic activity. This study shows that two out of 27 strains of Lactobacillus examined possess an antimicrobial effect against six species of gas-forming coliforms isolated from colicky infants. Our findings may stimulate new researches to identify which Lactobacillus strains can improve colicky symptoms by acting on coliforms gut colonization.
Water quality in turkey farms in Khemisset (Morocco) and potential risk factors.
El Allaoui, A; Rhazi Filali, F; Derouich, A
2016-12-01
The objectives of this study were to assess the microbiological and physical/chemical quality of water in broiler turkey farms in the province of Khemisset (north-western Morocco) and, based on a questionnaire, to ascertain potential risk factors for contamination of drinking water with faecal coliforms. A total of 80 samples were collected and analysed in 20 farms (four from each farm). At the main inlet to the water line at the entrance to each turkey house, 100% of the samples were of unacceptable quality in terms of faecal coliforms, Escherichia coli, faecal streptococci, sulphitereducing anaerobes and enterococci. A significant reduction in microbiological contamination of the water line (p < 0.05) was observed on Day 60. While more than 90% of the samples were of satisfactory quality in terms of pH, nitrites, conductivity, nitrates and iron, only 35% were satisfactory in terms of total hardness and only 20% met quality standards for ammonium content. The factors affecting levels of contamination with faecal coliforms were water chlorination (p = 0.065; odds ratio = 14; 90% confidence interval [CI] = 1.14-71), cleaning and disinfection (p = 0.028; odds ratio = 14; 95% CI = 1.25-156.6) and antibiotic treatment (p = 0.001; odds ratio = 6; 95% CI = 2.1-35.2). To improve water quality in poultry farms, farmers are advised to protect wells from contamination and to install water purification units (pre-oxidation, coagulation, flocculation, disinfection). In addition, turkey houses and rearing equipment should be rigorously cleaned and disinfected between each batch of birds. © OIE (World Organisation for Animal Health), 2016.
Zhang, Can; Liu, Wen-jun; Ao, Lu; Shi, Yun; An, Dai-zhi; Liu, Zhi-ping
2015-12-01
A survey of endotoxin activity in groundwater from 14 self-contained wells in PLA units stationed in Beijing was conducted by the kinetic-turbid assay of Tachypleus Amebocyte Lysate (TAL). Bacteriological parameters, including total cell counts detected by flow cytometry, heterotrophic plate counts (HPC), standard plate counts and total coliforms were analyzed. Additionally, suspended particles, turbidity, dissolved organic carbon (DOC), and UV₂₅₄ were investigated. Total endotoxin activities ranged from 0. 15 to 13.20 EU · mL⁻¹, free endotoxin activities ranged from 0.10 to 5.29 EU · mL⁻¹ and bound endotoxin activities ranged from 0.01 to 8.60 EU · mL⁻¹. Most of the endotoxins in heavily contaminated groundwater existed as bound endotoxins. As for total endotoxins, the sequence of correlation coefficients with other parameters was total cell counts (r = 0.88 ) > HPC (r = 0.79) > DOC (r = 0.77) > UV₂₅₄ (r = 0.57) > total coliforms (r = 0.50) > standard plate counts (r = 0.49) = turbidity (r = 0. 49) > total particles (r = 0.41). The sequence of correlations of the bound endotoxins with other parameters was total cell counts (r = 0.81) > HPC (r = 0.66) > total coliforms (r = 0.65) > turbidity (r = 0.62) > total particles (r = 0.58) > standard plate counts (r = 0.22). Free endotoxins were correlated with DOC and UV₂₅₄, r = 0.58 and 0.26, respectively. Result showed free endotoxins had a higher correlation with DOC, and a lower correlation with UV₂₅₄.
Russell, Gary M.; Hanson, Chris E.; Pitt, William A.J.
1978-01-01
Water quality in the Old Plantation Water Control District in Broward County, Florida has been affected by effluent from sewage-treatment plants, agriculture, and storm-water runoff. Effect of effluent from sewage-treatment plants on water quality was evident at 3 sites where concentrations of nutrients and bacteria in the Broward County canals exceeded State standards of 2,400 colonies per 100 milliliters for total coliform bacteria. At 2 of the 3 sites the fecal coliform/fecal streptococcus ratios indicated possible human contamination. The effect of agriculture on water quality was evident where relatively high levels of chlorinated hydrocarbon insecticides had concentrated in the bottom sediments, of the canals. For example, DDD reached levels of 330 micrograms per kilogram at one site. The effects of storm-water runoff on water quality were detected during the wet season when concentrations of several trace elements increased. For example, zinc averaged 30 micrograms per milliliter in the wet season compared with 20 micrograms per milliliter during the dry season. (Woodard-USGS)
Izumi, Hidemi; Nakata, Yuji; Inoue, Ayano
2016-10-01
Chemical sanitizers may induce no injury (bacteria survive), sublethal injury (bacteria are injured), or lethal injury (bacteria die). The proportion of coliform bacteria that were injured sublethally by chlorine and fungicide mixed with agricultural water (pond water), which was used to dilute the pesticide solution, was evaluated using the thin agar layer (TAL) method. In pure cultures of Enterobacter cloacae , Escherichia coli , and E. coli O157:H7 (representing a human pathogen), the percentage of chlorine-injured cells was 69 to 77% for dilute electrolyzed water containing an available chlorine level of 2 ppm. When agricultural water was mixed with electrolyzed water, the percentage of injured coliforms in agricultural water was 75%. The isolation and identification of bacteria on TAL and selective media suggested that the chlorine stress caused injury to Enterobacter kobei . Of the four fungicide products tested, diluted to their recommended concentrations, Topsin-M, Sumilex, and Oxirane caused injury to coliform bacteria in pure cultures and in agricultural water following their mixture with each pesticide, whereas Streptomycin did not induce any injury to the bacteria. The percentage of injury was 45 to 97% for Topsin-M, 80 to 87% for Sumilex, and 50 to 97% for Oxirane. A comparison of the coliforms isolated from the pesticide solutions and then grown on either TAL or selective media indicated the possibility of fungicide-injured Rahnella aquatilis , Yersinia mollaretii , and E. coli . These results suggest the importance of selecting a suitable sanitizer and the necessity of adjusting the sanitizer concentration to a level that will kill the coliforms rather than cause sanitizer-induced cell injury that can result in the recovery of the coliforms.
Alqahtani, Jobran M.; Asaad, Ahmed M.; Ahmed, Essam M.; Qureshi, Mohamed A.
2015-01-01
Aim of the Study: The aim was to investigate the bacteriological quality of drinking water, and explore the factors involved in the knowledge of the public about the quality of drinking water in Najran region, Saudi Arabia. Study Design: A cross-sectional descriptive study. Materials and Methods: A total of 160 water samples were collected. Total coliforms, fecal coliform, and fecal streptococci were counted using Most Probable Number method. The bacterial genes lacZ and uidA specific to total coliforms and Escherichia coli, respectively, were detected using multiplex polymerase chain reaction. An interview was conducted with 1200 residents using a questionnaire. Results: Total coliforms were detected in 8 (20%) of 40 samples from wells, 13 (32.5%) of 40 samples from tankers, and 55 (68.8%) of 80 samples from roof tanks. Twenty (25%) and 8 (10%) samples from roof tanks were positive for E. coli and Streptococcus faecalis, respectively. Of the 1200 residents participating in the study, 10%, 45.5%, and 44.5% claimed that they depended on municipal water, bottled water, and well water, respectively. The majority (95.5%) reported the use of roof water tanks as a source of water supply in their homes. Most people (80%) believed that drinking water transmitted diseases. However, only 25% of them participated in educational programs on the effect of polluted water on health. Conclusions: Our results could help health authorities consider a proper regular monitoring program and a sustainable continuous assessment of the quality of well water. In addition, this study highlights the importance of the awareness and educational programs for residents on the effect of polluted water on public health. PMID:25657607
Multidrug-Resistant Bacteria Isolated from Surface Water in Bassaseachic Falls National Park, Mexico
Delgado-Gardea, Ma. Carmen E.; Tamez-Guerra, Patricia; Gomez-Flores, Ricardo; Zavala-Díaz de la Serna, Francisco Javier; Eroza-de la Vega, Gilberto; Nevárez-Moorillón, Guadalupe Virginia; Pérez-Recoder, María Concepción; Sánchez-Ramírez, Blanca; González-Horta, María del Carmen; Infante-Ramírez, Rocío
2016-01-01
Bacterial pathogens are a leading cause of waterborne disease, and may result in gastrointestinal outbreaks worldwide. Inhabitants of the Bassaseachic Falls National Park in Chihuahua, Mexico show seasonal gastroenteritis problems. This aim of this study was to detect enteropathogenic microorganisms responsible for diarrheal outbreaks in this area. In 2013, 49 surface water samples from 13 selected sampling sites along the Basaseachi waterfall and its main rivers, were collected during the spring, summer, autumn, and winter seasons. Fecal and total coliform counts were determined using standard methods; the AutoScan-4 system was used for identification of isolates and the antibiotic resistance profile by challenging each organism using 21 antibiotics. Significant differences among seasons were detected, where autumn samples resulted in the highest total (p < 0.05) and fecal (p < 0.001) coliform counts, whereas the lowest total coliform counts were recorded in spring. Significant differences between sampling sites were observed, where samples from sites 6, 8, and 11 had the highest total coliform counts (p < 0.009), whereas samples from site 9 exhibited the lowest one. From the microbiological analysis, 33 bacterial isolates from 13 different sites and four sampling seasons were selected; 53% of isolates were resistant to at least one antibiotic, and 15% exhibited a multidrug resistance (MDB) phenotype. MDB were identified as Klebsiella oxytoca (two out of four identified isolates), Escherichia coli (2/7), and Enterobacter cloacae (1/3). In addition, some water-borne microorganisms exhibited resistance to cefazoline, cefuroxime, ampicillin, and ampicillin-sulbactam. The presence of these microorganisms near rural settlements suggests that wastewater is the contamination source, providing one possible transmission mechanism for diarrheal outbreaks. PMID:27322297
Delgado-Gardea, Ma Carmen E; Tamez-Guerra, Patricia; Gomez-Flores, Ricardo; Zavala-Díaz de la Serna, Francisco Javier; Eroza-de la Vega, Gilberto; Nevárez-Moorillón, Guadalupe Virginia; Pérez-Recoder, María Concepción; Sánchez-Ramírez, Blanca; González-Horta, María Del Carmen; Infante-Ramírez, Rocío
2016-06-16
Bacterial pathogens are a leading cause of waterborne disease, and may result in gastrointestinal outbreaks worldwide. Inhabitants of the Bassaseachic Falls National Park in Chihuahua, Mexico show seasonal gastroenteritis problems. This aim of this study was to detect enteropathogenic microorganisms responsible for diarrheal outbreaks in this area. In 2013, 49 surface water samples from 13 selected sampling sites along the Basaseachi waterfall and its main rivers, were collected during the spring, summer, autumn, and winter seasons. Fecal and total coliform counts were determined using standard methods; the AutoScan-4 system was used for identification of isolates and the antibiotic resistance profile by challenging each organism using 21 antibiotics. Significant differences among seasons were detected, where autumn samples resulted in the highest total (p < 0.05) and fecal (p < 0.001) coliform counts, whereas the lowest total coliform counts were recorded in spring. Significant differences between sampling sites were observed, where samples from sites 6, 8, and 11 had the highest total coliform counts (p < 0.009), whereas samples from site 9 exhibited the lowest one. From the microbiological analysis, 33 bacterial isolates from 13 different sites and four sampling seasons were selected; 53% of isolates were resistant to at least one antibiotic, and 15% exhibited a multidrug resistance (MDB) phenotype. MDB were identified as Klebsiella oxytoca (two out of four identified isolates), Escherichia coli (2/7), and Enterobacter cloacae (1/3). In addition, some water-borne microorganisms exhibited resistance to cefazoline, cefuroxime, ampicillin, and ampicillin-sulbactam. The presence of these microorganisms near rural settlements suggests that wastewater is the contamination source, providing one possible transmission mechanism for diarrheal outbreaks.
Seasonality of water quality and diarrheal disease counts in urban and rural settings in south India
NASA Astrophysics Data System (ADS)
Kulinkina, Alexandra V.; Mohan, Venkat R.; Francis, Mark R.; Kattula, Deepthi; Sarkar, Rajiv; Plummer, Jeanine D.; Ward, Honorine; Kang, Gagandeep; Balraj, Vinohar; Naumova, Elena N.
2016-02-01
The study examined relationships among meteorological parameters, water quality and diarrheal disease counts in two urban and three rural sites in Tamil Nadu, India. Disease surveillance was conducted between August 2010 and March 2012; concurrently water samples from street-level taps in piped distribution systems and from household storage containers were tested for pH, nitrate, total dissolved solids, and total and fecal coliforms. Methodological advances in data collection (concurrent prospective disease surveillance and environmental monitoring) and analysis (preserving temporality within the data through time series analysis) were used to quantify independent effects of meteorological conditions and water quality on diarrheal risk. The utility of a local calendar in communicating seasonality is also presented. Piped distribution systems in the study area showed high seasonal fluctuations in water quality. Higher ambient temperature decreased and higher rainfall increased diarrheal risk with temperature being the predominant factor in urban and rainfall in rural sites. Associations with microbial contamination were inconsistent; however, disease risk in the urban sites increased with higher median household total coliform concentrations. Understanding seasonal patterns in health outcomes and their temporal links to environmental exposures may lead to improvements in prospective environmental and disease surveillance tailored to addressing public health problems.
Montanhini, Maike Taís Maziero; Montanhini Neto, Roberto
2015-01-01
This study aimed to determine the effect of temperature and period of postharvest storage on the microbiological quality and shelf life of raw mangrove oysters, Crassostrea brasiliana. A total of 150 dozen oysters were collected directly from the points of extraction or cultivation in southern Brazil, and in the laboratory, they were stored raw at 5, 10, 15, 20, and 25°C for 1, 4, 8, 11, and 15 days. On each of these days, the oysters were subjected to microbiological analyses of aerobic mesophilic count, total coliforms, enterococci, Escherichia coli, Staphylococcus aureus, and Salmonella. None of the tested samples under any storage condition showed contamination levels above those allowed by Brazilian legislation for E. coli, S. aureus, and Salmonella, and there was no change (P > 0.05) in the counts of these microorganisms due to the temperature and/or period of oyster storage. Counts of enterococci and total coliforms showed a tendency to increase (P < 0.05) among the different temperatures tested. Raw mangrove oysters remain in safe microbiological conditions for consumption up to 8 days after harvesting, regardless of temperature, and their shelf life may be extended to 15 days if they are stored at temperatures not exceeding 15°C.
Brooks, John P; Adeli, Ardeshir; Read, John J; McLaughlin, Michael R
2009-01-01
Runoff water following a rain event is one possible source of environmental contamination after a manure application. This greenhouse study used a rainfall simulator to determine bacterial-associated runoff from troughs of common bermudagrass [Cynodon dactylon (L.) Pers.] that were treated with P-based, N-based, and N plus lime rates of poultry (Gallus gallus) litter, recommended inorganic fertilizer, and control. Total heterotrophic plate count (HPC) bacteria, total and thermotolerant coliforms, enterococci, staphylococci, Clostridium perfringens, Salmonella, and Campylobacter, as well as antibiotic resistance profiles for the staphylococci and enterococci isolates were all monitored in runoff waters. Analysis following five rainfall events indicated that staphylococci, enterococci, and clostridia levels were related to manure application rate. Runoff release of staphylococci, enterococci, and C. perfringens were approximately 3 to 6 log10 greater in litter vs. control treatment. In addition, traditional indicators such as thermotolerant and total coliforms performed poorly as fecal indicators. Some isolated enterococci demonstrated increased antibiotic resistance to polymixin b and/or select aminoglyocosides, while many staphylococci were susceptible to most antimicrobials tested. Results indicated poultry litter application can lead to microbial runoff following simulated rain events. Future studies should focus on the use of staphylococci, enterococci, and C. perfringens as indicators.
Virological and bacteriological quality of drinking water in Ethiopia
NASA Astrophysics Data System (ADS)
Bedada, Tesfaye Legesse; Mezemir, Walelign Dessie; Dera, Firehiwot Abera; Sima, Waktole Gobena; Gebre, Samson Girma; Edicho, Redwan Muzeyin; Biegna, Almaz Gonfa; Teklu, Dejenie Shiferaw; Tullu, Kassu Desta
2018-05-01
Since unsafe water is responsible for many illness, deaths, and economic failure, water quality monitoring is essential. A cross-sectional study was conducted on 218 drinking waters samples collected between February and June 2016 to assess water quality using phages by the help of CB390 E. coli host, plaque assay; multiple tube fermentation for coliforms and pour plate for heterotrophic bacteria at Ethiopian Public Health Institute. Heterotrophic plate count greater than 100 cfu/ml was noted in 41 samples and detections of total and thermotolerant coliforms and E. coli in 38, 24, and 10 samples, respectively, and no phages detection in chlorinated waters. While heterotrophic plate count greater than 100 cfu/ml was observed in 100 samples and detections of total and thermotolerant coliforms, E. coli, and phages in 75, 60, 42, and 5 samples, respectively, for untreated waters. The majority of the waters contained indicators above standard limits. This indicates that the sources are contaminated and they are potential threats for health. Hence, regular water monitoring should be a priority agenda.
Mavangira, Vengai; Gandy, Jeffery C; Zhang, Chen; Ryman, Valerie E; Daniel Jones, A; Sordillo, Lorraine M
2015-09-01
Coliform mastitis is a severe and sometimes fatal disease characterized by an unregulated inflammatory response. The initiation, progression, and resolution of inflammatory responses are regulated, in part, by potent oxylipid metabolites derived from polyunsaturated fatty acids. The purpose of this study was to characterize the biosynthesis and diversity of oxylipid metabolites during acute bovine coliform mastitis. Eleven cows diagnosed with naturally occurring acute systemic coliform mastitis and 13 healthy control cows, matched for lactation number and days in milk, were selected for comparison of oxylipid and free fatty acid concentrations in both milk and plasma. Oxylipids and free fatty acids were quantified using liquid chromatography-tandem mass spectrometry. All polyunsaturated fatty acids quantified in milk were elevated during coliform mastitis with linoleic acid being the most abundant. Oxylipids synthesized through the lipoxygenase and cytochrome P450 pathways accounted for the majority of the oxylipid biosynthesis. This study demonstrated a complex and diverse oxylipid network, most pronounced at the level of the mammary gland. Substrate availability, biosynthetic pathways, and degree of metabolism influence the biosynthesis of oxylipids during bovine coliform mastitis. Further studies are required to identify targets for novel interventions that modulate oxylipid biosynthesis during coliform mastitis to optimize inflammation. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Kämpfer, Peter; Nienhüser, Anita; Packroff, Gabriele; Wernicke, Frank; Mehling, Arnd; Nixdorf, Katja; Fiedler, Stefanie; Kolauch, Claudia; Esser, Michael
2008-07-01
The accuracy of a traditional method (lactose utilization with acid and gas production) for the detection of coliform bacteria and E. coli was tested in comparison with method ISO 9308-1 (based on acid formation from lactose) and the Colilert-18 system (detection of beta-galactosidase). A total of 345 isolates were identified after isolation from water samples using API 20E strips. The Colilert-18 led to the highest number of positive findings (95% of the isolates were assigned to coliforms), whereas the ISO-9308-1 method resulted only in 29% coliform findings. With the traditional method only 15% were rated positive. Most of the isolates were identified by the API 20E system as Enterobacter spp. (species of the Enterobacter cloacae complex), Serratia spp., Citrobacter spp.and Klebsiella spp.; but species identification remained vague in several cases. A more detailed identification of 126 pure cultures by using 16S rRNA gene sequence analysis and analysis of the hsp60 gene resulted in the identification of Enterobacter nimipressuralis, E. amnigenus, E. asburiae, E. hormaechei, and Serratia fonticola as predominat coliforms. These species are beta-galactosidase positive, but show acid formation from lactose often after a prolonged incubation time. They are often not of fecal origin and may interfere with the ability to accurately detect coliforms of fecal origin.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1987-09-01
This report contains an analysis of the costs and benefits of controlling microbial contaminants in drinking water through the promulgation of two regulations: (1) the Surface Water Treatment Rule (SWTR); and (2) the Total Coliform Rule. This regulatory impact analysis (RIA) was prepared in accordance with Executive Order 12291, which requires that the costs and benefits of all major rules be examined and compared. The major topical areas covered in the RIA are as follows: problem definition; market imperfections, the need for federal regulation, and consideration of regulatory alternatives; assessment of total costs; assessment of benefits; regulatory flexibility act andmore » Paperwork Reduction Act analyses; and a summary of costs and benefits.« less
Limnological Monitoring on the Upper Mississippi River System, 1993-1996: Lake City Field Station
1999-10-01
Reports of this type provide a synopsis of the collected data and collection methods, as well as a preliminary report of remarkable or unusual conditions ... conditions . To meet this need, Congress authorized a Long Term Resource Monitoring Program (LTRMP) for the Upper Mississippi River System (UMRS). The LTRMP...primarily for human consumption or regulatory purposes (e.g., chemical oxygen demand, biochemical oxygen demand, total coliform bacteria , fecal coliform
[Microbiological studies in poultry meat production].
Monov, G
1981-01-01
Microbiologic studies were carried out in the production of poultry meat in a poultry dressing combine of the Stork system. Examined were a total of 125 washing samples taken at the 9th, 11th and 15th hour from the scalding vat, the cooling vat, the machine of eviscerating and the skin surface after plucking, eviscerating and shower washing and prior to packing the carcasses. It was found that the count of aerobic organisms continuously rose during the technologic processing of the slaughtered birds with regard to the surface of the carcasses, the peak values of the total counts and that of coliforms being reached during evisceration. It was further established that shower washing of the carcasses immediately following evisceration guaranteed a washing effect so far as the microflora on the surface was concerned, amounting to 77.60 per cent. So far as the coliform bacteria was concerned this effect was found to be equal to 89.78 per cent. The total count of aerobic microflora on the surface of carcasses prior to packing was found to vary within the range of 3000 to 72000, while the count of coliforms ranged from 100 to 1800/cm2.
Shahryari, A; Nikaeen, M; Khiadani Hajian, M; Nabavi, F; Hatamzadeh, M; Hassanzadeh, A
2014-11-01
Water quality monitoring is essential for the provision of safe drinking water. In this study, we compared a selection of fecal indicators with universal Bacteroidales genetic marker to identify fecal pollution of a variety of drinking water sources. A total of 60 samples were collected from water sources. The microbiological parameters included total coliforms, fecal coliforms, Escherichia coli and fecal streptococci as the fecal indicator bacteria (FIB), Clostridium perfringens and H2S bacteria as alternative indicators, universal Bacteroidales genetic marker as a promising alternative fecal indicator, and Salmonella spp., Shigella spp., and E. coli O157 as pathogenic bacteria. From 60 samples analyzed, Bacteroidales was the most frequently detected indicator followed by total coliforms. However, the Bacteroidales assay failed to detect the marker in nine samples positive for FIB and other alternative indicators. The results of our study showed that the absence of Bacteroidales is not necessarily an evidence of fecal and pathogenic bacteria absence and may be unable to ensure the safety of the water. Further research, however, is required for a better understanding of the use of a Bacteroidales genetic marker as an indicator in water quality monitoring programs.
Davoodi, Reza; Pirsaheb, Meghdad; Karimyan, Kamaladdin; Gupta, Vinod Kumar; Takhtshahi, Ali Reza; Sharafi, Hooshmand; Moradi, Masoud
2018-06-01
This study was aimed to investigate the distribution of various species of fecal coliform in urban, rural and private drinking water sources of Kermanshah, in the west of Iran. For this study, data of ten years period (2006-2016) assessments of microbial quality regarding various species of Fecal coliforms was taken from health centers associated with urban, rural and private resources of Kermanshah city. A total number of 8643 samples were taken, 1851 samples from rural, 365 from urban and 4834 from private resources. The results showed that Fecal coliforms , Escherichia coli ( E. coli ) had the widest distribution in all urban, rural and private water resources (22.3%, 45.9% and 34%, respectively). Moreover, E. coli (47.5%) and Klebsiella (0.4%) had, respectively, the highest and lowest distribution in all months considered. Based on the results, E.coli exists mostly in water resources; it is therefore of particular importance in the monitoring of water resources.
Zhang, K; Farahbakhsh, K
2007-06-01
The efficacy of a conventional activated sludge wastewater treatment process and the membrane bioreactor technology in removing microbial pathogens was investigated. Total and fecal coliforms and somatic and F-specific coliphages were used as indicators of pathogenic bacteria and viruses. Up to 5.7 logs removal of coliforms and 5.5 logs of coliphages were observed in the conventional treatment process with advanced tertiary treatment. Addition of chemical coagulants seemed to improve the efficacy of primary and secondary treatment for microorganism removal. Complete removal of fecal coliforms and up to 5.8 logs removal of coliphages was observed in the MBR system. It was shown that the MBR system was capable of high removal of coliphages despite the variation in feed coliphage concentrations. The results of this study indicated that the MBR system can achieve better microbial removal in far fewer steps than the conventional activated sludge process with advanced tertiary treatment. The final effluent from either treatment processes can be potentially reused.
Francy, Donna S.; Bushon, Rebecca N.; Stopar, Julie; Luzano, Emma J.; Fout, G. Shay
2004-01-01
A study of small public ground-water-supply wells that produce water from discontinuous sand and gravel aquifers was done from July 1999 through July 2001 in southeastern Michigan. Samples were collected to determine the occurrence of viral pathogens and microbiological indicators of fecal contamination (indicators), determine whether indicators are adequate predictors of the presence of enteric viruses, and determine the factors that affect the presence of enteric viruses. Small systems are those that serve less than 3,300 people. Samples were analyzed for specific enteric viruses by reverse transcriptase-polymerase chain reaction (RT-PCR), for culturable viruses by cell culture, and for the indicators total coliforms, Escherichia coli (E. coli), enterococci, and F-specific and somatic coliphage. Ancillary environmental and water-quality data were collected or compiled. A total of 169 regular samples and 32 replicate pairs were collected from 38 wells. Replicate pairs were samples collected at the same well on the same date. One well was sampled 6 times, 30 wells were sampled five times, 6 wells were sampled twice, and 1 well was sampled once. By use of RT-PCR, enterovirus was found in four wells (10.5 percent) and hepatitis A virus (HAV) in five wells (13.2 percent). In two of these wells, investigators found both enterovirus and HAV, but on different sampling dates. Culturable viruses were found one time in two wells (5.9 percent), and neither of these wells was positive for viruses by use of RT-PCR on any sampling date. If results for all viruses are combined, 9 of the 38 small public-supply wells were positive for enteric viruses (23.7 percent) by either cell culture or RT-PCR. One or more indicators were found in 18 of 38 wells. Total coliforms, E. coli, enterococci, and F-specific and somatic coliphage were found in 34.2, 10.5, 15.8, 5.9, and 5.9 percent, respectively, of the wells tested. In only 3 out of 18 wells were samples positive for an indicator on more than one date at the same well. The co-occurrence of enteric viruses and any indicator was 55.6 percent; five out of the nine virus-positive wells were also found to be positive for an indicator. Two wells with detections of viruses had a detection of total coliforms, one well had a detection of E. coli, one of enterococci, and one of F-specific coliphage. On a per sample basis, of 11 samples that were positive for enteric viruses, indicator bacteria co-occurred in only 2 samples, and coliphage were not present in any. More virus-positive samples were found at sites served by septic systems than those served by sewerlines. Sampling condition (ground water or a mixture of tank and ground water), distance to septic system, type of and distance to nearest surface-water body, well characteristics, or land use were not related to the presence of viruses or indicators. Among continuous water-quality variables, statistically significant relations were found between total coliforms and dissolved organic carbon and between total coliforms and iron. There was a statistically significant relation between chloride concentrations >20 mg/L and detections of total coliforms. Presence of nitrate and nitrite was related to the presence of other indicators (E. coli, enterococci, and F-specific and somatic coliphage) or enteric viruses, but not to total coliforms. The data indicated that chloride-to-bromide (C1:Br) ratios may be useful as a screening tool for total coliforms and enteric viruses but not for E. coli, enterococci, and F-specific and somatic coliphage. This study provides evidence for fecal contamination of ground water from small public-supply wells, at least on an intermittent basis. Collecting data on multiple lines of evidence would be needed to reliably predict the presence of enteric viruses and protect public health. Future data collection toward this end could include repeat sampling several times a year for different indicators, measuring dissolv
Barreto de Deus, Tamiles; Mendes da Silva, Ricardo; Karine da Silva Lima, Wanessa; Virgens Lima, Danuza das; dos Santos Silva, Adriana
2017-01-01
The present study evaluated the microbiological and sanitary quality of curd cheese sold on the beaches of the Itaparica Island, Brazil, and verified whether a correlation exists between the commercialization conditions and the microbiological data. The research was performed between December 2015 and March 2017. Sixty samples of rennet-containing cheese were collected to estimate the populations of mesophylls, psychrotrophic microorganisms, mold and yeast, Staphylococcus aureus, total coliforms, and Escherichia coli. An observational analysis was performed during the collection, using a checklist to verify the sellers' sanitary conditions and cheese marketing. A high nonconformity index was registered regarding aspects in the checklist. In the microbiological analyses, the number of mesophylls in raw and roasted samples ranged from 7,88 to 14,82 log CFU/mL, and those of psychrotrophs ranged from 2,80 to 3,84 log CFU/mL. Meanwhile, mold and yeast levels in the samples ranged from 8,06 to 5,54 log CFU/mL, S. aureus was detected at levels from 3,24 to 4,94 log CFU/mL, and the total coliform counts ranged from 4,48 to 7,18 log CFU/mL. The number of E. coli specimens ranged from 2,96 to 5,75 log CFU/mL. Microbial insecurity was noted for commercialized curd cheese, and the need for intervention was indicated. PMID:29362565
Quality of wastewater reuse in agricultural irrigation and its impact on public health.
Al-Hammad, Bushra Ahmed; Abd El-Salam, Magda Magdy; Ibrahim, Sahar Yassin
2014-11-01
This study is planned to perform a sanitary survey of the largest sewage treatment plant in Riyadh, KSA, fortnightly for 6 months to examine its effluent quality as an example for the growing dependence on reuse of treated municipal wastewater in agricultural irrigation purposes to cope with increasing water shortage. The biological and physico-chemical parameters of 12 wastewater samples from the plant were examined using standard methods. The physico-chemical analysis indicated that the surveyed municipal wastewater treatment plant contained some of the studied parameters, such as turbidity, total suspended solids, biochemical oxygen demand, chemical oxygen demand and residual chlorine above the maximum permissible wastewater limits set by the Saudi Standards. However, heavy metal concentrations in all samples were lower than the recommended standards. Total and faecal coliform counts were above the permissible limits indicating poor sanitation level. Fifty percent of all wastewater samples were contaminated with faecal coliforms but, surprisingly, Escherichia coli were only detected in 8.3 % of the samples. Regular monitoring and enhancement of microbial and physico-chemical parameters of the wastewater quality served by different wastewater treatment plants for reuse in agricultural irrigation is recommended to preserve the environment and public health.
Bohaychuk, Valerie M.; Gensler, Gary E.; Barrios, Pablo Romero
2011-01-01
In 2006 and 2007 beef and pork carcass swabs from provincially inspected abattoirs in Alberta, Canada were tested to determine the levels of total aerobic bacteria, coliform bacteria, and generic Escherichia coli, and the prevalence of Salmonella spp., Campylobacter spp., and Shiga toxin-producing E. coli (STEC). Swabs from beef and pork carcasses from 48 and 34 facilities, respectively, were analyzed. All samples tested were positive for aerobic bacteria with 99.8% of beef and 96.0% of pork samples, having total counts of ≤ 100 000 CFU/cm2. Coliform bacteria were isolated from 22.4% and 42.0% of beef and pork carcass samples, respectively. Generic E. coli were recovered from 14.6% of beef and 33.7% of pork carcass samples. For beef carcasses, positive tests were obtained for 0.1% of 1036 samples tested for Salmonella spp., 1.5% of 1022 samples tested for Campylobacter spp. and 5.4% of 1018 samples tested for STEC. For pork carcasses, positive tests were obtained for 1.6 % of 1076 samples tested for Salmonella spp., 8.8% of 1070 samples tested for Campylobacter spp. and 4.8% of 1067 samples tested for STEC. PMID:22467964
NASA Astrophysics Data System (ADS)
Kisi, Ozgur; Parmar, Kulwinder Singh
2016-03-01
This study investigates the accuracy of least square support vector machine (LSSVM), multivariate adaptive regression splines (MARS) and M5 model tree (M5Tree) in modeling river water pollution. Various combinations of water quality parameters, Free Ammonia (AMM), Total Kjeldahl Nitrogen (TKN), Water Temperature (WT), Total Coliform (TC), Fecal Coliform (FC) and Potential of Hydrogen (pH) monitored at Nizamuddin, Delhi Yamuna River in India were used as inputs to the applied models. Results indicated that the LSSVM and MARS models had almost same accuracy and they performed better than the M5Tree model in modeling monthly chemical oxygen demand (COD). The average root mean square error (RMSE) of the LSSVM and M5Tree models was decreased by 1.47% and 19.1% using MARS model, respectively. Adding TC input to the models did not increase their accuracy in modeling COD while adding FC and pH inputs to the models generally decreased the accuracy. The overall results indicated that the MARS and LSSVM models could be successfully used in estimating monthly river water pollution level by using AMM, TKN and WT parameters as inputs.
Assessment of microbiological quality of drinking water from household tanks in Bermuda.
Lévesque, B; Pereg, D; Watkinson, E; Maguire, J S; Bissonnette, L; Gingras, S; Rouja, P; Bergeron, M G; Dewailly, E
2008-06-01
Bermuda residents collect rainwater from rooftops to fulfil their freshwater needs. The objective of this study was to assess the microbiological quality of drinking water in household tanks throughout Bermuda. The tanks surveyed were selected randomly from the electoral register. Governmental officers visited the selected household (n = 102) to collect water samples and administer a short questionnaire about the tank characteristics, the residents' habits in terms of water use, and general information on the water collecting system and its maintenance. At the same time, water samples were collected for analysis and total coliforms and Escherichia coli were determined by 2 methods (membrane filtration and culture on chromogenic media, Colilert kit). Results from the 2 methods were highly correlated and showed that approximately 90% of the samples analysed were contaminated with total coliforms in concentrations exceeding 10 CFU/100 mL, and approximately 66% of samples showed contamination with E. coli. Tank cleaning in the year prior to sampling seems to protect against water contamination. If rainwater collection from roofs is the most efficient mean for providing freshwater to Bermudians, it must not be considered a source of high quality drinking water because of the high levels of microbial contamination.
Firth, Jacqueline; Balraj, Vinohar; Muliyil, Jayaprakash; Roy, Sheela; Rani, Lilly Michael; Chandresekhar, R.; Kang, Gagandeep
2010-01-01
To assess water contamination and the relative effectiveness of three options for point-of-use water treatment in South India, we conducted a 6-month randomized, controlled intervention trial using chlorine, Moringa oleifera seeds, a closed valved container, and controls. One hundred twenty-six families participated. Approximately 70% of public drinking water sources had thermotolerant coliform counts > 100/100 mL. Neither M. oleifera seeds nor containers reduced coliform counts in water samples from participants' homes. Chlorine reduced thermotolerant coliform counts to potable levels, but was less acceptable to participants. Laboratory testing of M. oleifera seeds in water from the village confirmed the lack of reduction in coliform counts, in contrast to the improvement seen with Escherichia coli seeded distilled water. This discrepancy merits further study, as M. oleifera was effective in reducing coliform counts in other studies and compliance with Moringa use in this study was high. PMID:20439952
Firth, Jacqueline; Balraj, Vinohar; Muliyil, Jayaprakash; Roy, Sheela; Rani, Lilly Michael; Chandresekhar, R; Kang, Gagandeep
2010-05-01
To assess water contamination and the relative effectiveness of three options for point-of-use water treatment in South India, we conducted a 6-month randomized, controlled intervention trial using chlorine, Moringa oleifera seeds, a closed valved container, and controls. One hundred twenty-six families participated. Approximately 70% of public drinking water sources had thermotolerant coliform counts > 100/100 mL. Neither M. oleifera seeds nor containers reduced coliform counts in water samples from participants' homes. Chlorine reduced thermotolerant coliform counts to potable levels, but was less acceptable to participants. Laboratory testing of M. oleifera seeds in water from the village confirmed the lack of reduction in coliform counts, in contrast to the improvement seen with Escherichia coli seeded distilled water. This discrepancy merits further study, as M. oleifera was effective in reducing coliform counts in other studies and compliance with Moringa use in this study was high.
Eddins, W.H.; Crawford, J.K.
1984-01-01
In 1979-81, water samples were collected from 119 sites on streams throughout the City of Charlotte and Mecklenburg County, North Carolina, and were analyzed for specific conductance, dissolved chloride, hardness, pH, total alkalinity, total phosphorus, trace elements, arsenic, cadmium, chromium, copper, iron, lead, manganese, mercury, silver, and zinc and biological measures including dissolved oxygen, biochemical oxygen demand, fecal coliform bacteria, and fecal streptococcus bacteria. Sampling was conducted during both low flow (base flow) and high flow. Several water-quality measures including pH, total arsenic, total cadmium, total chromium, total copper, total iron, total lead, total manganese, total mercury, total silver, total zinc, dissolved oxygen, and fecal coliform bacteria at times exceeded North Carolina water-quality standards in various streams. Runoff from non-point sources appears to contribute more to the deterioration of streams in Charlotte and Mecklenburg County than point-source effluents. Urban and industrial areas contribute various trace elements. Residential and rural areas and municipal waste-water treatment plants contribute high amounts of phosphorus.
Tantawiwat, Suwalee; Tansuphasiri, Unchalee; Wongwit, Waranya; Wongchotigul, Varee; Kitayaporn, Dwip
2005-01-01
Multiplex PCR amplification of lacZ, uidA and plc genes was developed for the simultaneous detection of total coliform bacteria for Escherichia coli and Clostridium perfringens, in drinking water. Detection by agarose gel electrophoresis yielded a band of 876 bp for the lacZ gene of all coliform bacteria; a band of 147 bp for the uidA gene and a band of 876 bp for the lacZ gene of all strains of E. coli; a band of 280 bp for the p/c gene for all strains of C. perfringens; and a negative result for all three genes when tested with other bacteria. The detection limit was 100 pg for E. coli and C. perfringens, and 1 ng for coliform bacteria when measured with purified DNA. This assay was applied to the detection of these bacteria in spiked water samples. Spiked water samples with 0-1,000 CFU/ml of coliform bacteria and/or E. coli and/or C. perfringens were detected by this multiplex PCR after a pre-enrichment step to increase the sensitivity and to ensure that the detection was based on the presence of cultivable bacteria. The result of bacterial detection from the multiplex PCR was comparable with that of a standard plate count on selective medium (p=0.62). When using standard plate counts as a gold standard, the sensitivity for this test was 99.1% (95% CI 95.33, 99.98) and the specificity was 90.9 % (95% CI 75.67, 98.08). Multiplex PCR amplification with a pre-enrichment step was shown to be an effective, sensitive and rapid method for the simultaneous detection of these three microbiological parameters in drinking water.
Retzlaff, Deanna; Phebus, Randall; Kastner, Curtis; Marsden, James
2005-01-01
A static chamber steam pasteurization unit (SPS 400-SC()) was installed in a high-volume commercial beef slaughter facility. The SPS 400-SC consists of a three-phase carcass treatment cycle of water removal, steam pasteurization, and water chilling. Seven chamber temperatures (71.1, 73.9, 76.7, 79.4, 82.2, 85.0, and 87.8 degrees C) were evaluated at the midline area of pre-rigor beef carcasses. For each temperature evaluated, 20 carcass sides were randomly selected and aseptically sampled by tissue excision immediately before and after steam pasteurization to determine total aerobic bacteria, Enterobacteriaceae, generic E. coli, and total coliform populations. The 87.8 and 85.0 degrees C treatment temperatures were highly effective at reducing total aerobic bacterial populations, with log(10) reductions of 1.4 and 1.5 CFU/cm(2), respectively, from pretreatment mean population levels of 1.7 and 1.9 log10 CFU/cm(2). These temperatures also reduced Enterobacteriaceae, total coliforms, and generic E. coli to undetectable levels (<0.4 CFU/cm(2)) on all carcasses sampled. Treatment at 82.2 was marginally effective at reducing bacterial populations, while 71.1, 73.9, 76.7, and 79.4 degrees C treatments were ineffective at reducing microbial populations. In a Hazard Analysis Critical Control Points (HACCP)-based system employing steam pasteurization of carcasses as a critical control point, a critical limit of 85.0 degrees C as a minimum chamber temperature should be established, with a targeted operating temperature of 87.8 degrees C providing optimum antimicrobial activity.
Drinking Water Quality of Water Vending Machines in Parit Raja, Batu Pahat, Johor
NASA Astrophysics Data System (ADS)
Hashim, N. H.; Yusop, H. M.
2016-07-01
An increased in demand from the consumer due to their perceptions on tap water quality is identified as one of the major factor on why they are mentally prepared to pay for the price of the better quality drinking water. The thought that filtered water quality including that are commercially available in the market such as mineral and bottled drinking water and from the drinking water vending machine makes they highly confident on the level of hygiene, safety and the mineral content of this type of drinking water. This study was investigated the vended water quality from the drinking water vending machine in eight locations in Parit Raja are in terms of pH, total dissolve solids (TDS), turbidity, mineral content (chromium, arsenic, cadmium, lead and nickel), total organic carbon (TOC), pH, total colony-forming units (CFU) and total coliform. All experiments were conducted in one month duration in triplicate samples for each sampling event. The results indicated the TDS and all heavy metals in eight vended water machines in Parit Raja area were found to be below the Food Act 1983, Regulation 360C (Standard for Packaged Drinking Water and Vended water, 2012) and Malaysian Drinking Water Quality, Ministry of Health 1983. No coliform was presence in any of the vended water samples. pH was found to be slightly excess the limit provided while turbidity was found to be 45 to 95 times more higher than 0.1 NTU as required by the Malaysian Food Act Regulation. The data obtained in this study would suggest the important of routine maintenance and inspection of vended water provider in order to maintain a good quality, hygienic and safety level of vended water.
2002-11-01
synopsis of the collected data and collection methods, as well as a preliminary report of remarkable or unusual conditions in the system. They are intended...resource requires scientific understanding of the ecosystem and of its long-term trends and conditions . To meet this need, Congress authorized a Long...chemical oxygen demand, biochemical oxygen demand, total coliform bacteria , fecal coliform bacteria , fecal streptococcus, heavy metals, pesticides, and
Analysis of microbiological contamination in mixed pressed ham and cooked sausage in Korea.
Park, Myoung-Su; Wang, Jun; Park, Joong-Hyun; Forghani, Fereidoun; Moon, Jin-San; Oh, Deog-Hwan
2014-03-01
The objective of this study was to investigate the microbial contamination levels (aerobic bacteria plate count [APC], coliforms, Escherichia coli, Staphylococcus aureus, and Listeria monocytogenes) in mixed pressed ham and cooked sausage. A total of 180 samples were collected from factories with and without hazard analysis critical control point (HACCP) systems at four steps: after chopping (AC), after mixing (AM), cooling after the first heating process, and cooling after the second heating process. For ham, APCs and coliform and E. coli counts increased when ingredients were added to the meat at the AC step. Final product APC was 1.63 to 1.85 log CFU/g, and coliforms and E. coli were not detected. S. aureus and L. monocytogenes were found in nine (15.0%) and six (10.0%) samples, respectively, but only at the AC and AM steps and not in the final product. Sausage results were similar to those for ham. The final product APC was 1.52 to 3.85 log CFU/g, and coliforms and E. coli were not detected. S. aureus and L. monocytogenes were found in 29 (24.2%) and 25 (20.8%) samples at the AC and AM steps, respectively, but not in the final product. These results indicate that the temperature and time of the first and second heating are of extreme importance to ensure the microbiological safety of the final product regardless of whether a HACCP system is in place. Microorganism contamination must be monitored regularly and regulations regarding sanitization during processing should be improved. Education regarding employee personal hygiene, environmental hygiene, prevention of cross-contamination, ingredient control, and step-by-step process control is needed to reduce the risk of food poisoning.
Ibe, Nnenne I.; Iroegbu, Christian U.
2011-01-01
Bacterial count in prepared food or water is a key factor in assessing the quality and safety of food. It also reveals the level of hygiene adopted by food handlers in the course of preparation of such foods. This comparative study evaluated the bacteriological quality of food and water consumed in Nsukka, Enugu state, Nigeria, using three bacteria enumeration methods. Data obtained are assumed to reflect the level of personal and environmental hygiene in the study population. Ten types of foods—beans, yam, abacha, okpa, moimoi, pear, cassava foofoo, rice, agidi, and garri—and 10 water samples were evaluated for bacteriological quality, precisely determining the level of coliform contamination, using the most probable number (MPN), lactose fermentation count (LFC), and Escherichia coli count (ECC) methods. Bacterial counts differed significantly (p<0.05) among the various food samples. However, this did not differ significantly in the three methods used for the enumeration of coliforms, suggesting that any of the three methods could be validly used for such studies with confidence. Escherichia coli and Klebsiella pneumoniae were the two major coliforms identified among 98 coliform isolates obtained from the various food samples, of which 78 (79.6%) were assumed to be of human origin on account of their ability to grow at 44 °C. The level of coliform contamination in the food samples from vendors and restaurants (geometric mean count 7.64-9.21; MPN ≥50) were above the accepted 104 colony-forming unit/g or MPN ≤10 limits. The results of the study, therefore, call for stringent supervision and implementation of food-safety practices and regular education on food and personal hygiene among food vendors. PMID:22283029
Entry, James A; Leytem, April B; Verwey, Sheryl
2005-11-01
We measured Escherichia coli, Enterococcus spp. and fecal coliform numbers in soil and on fresh potato skins after addition of solid dairy manure and dairy compost with and without alum (Al(2)(SO(4))(3)) treatment 1, 7, 14, 28, 179 and 297 days after application. The addition of dairy compost or solid dairy manure at rates to meet crop phosphorus uptake did not consistently increase E. coli and Enterococcus spp. and fecal coliform bacteria in the soil. We did not detect E. coli in any soil sample after the first sampling day. Seven, 14, 28, 179 and 297 days after solid dairy waste and compost and alum were applied to soil, alum did not consistently affect Enterococcus spp. and fecal coliform bacteria in the soil. We did not detect E. coli in any soil, fresh potato skin or potato wash-water at 214 days after dairy manure or compost application regardless of alum treatment. Dairy compost or solid dairy manure application to soil at rates to meet crop phosphorus uptake did not consistently increase Enterococcus spp. and fecal coliform numbers in bulk soil. Solid dairy manure application to soil at rates to meet crop phosphorus uptake, increased Enterococcus spp. and fecal coliform numbers in potato rhizosphere soil. However, fresh potato skins had higher Enterococcus spp. and fecal coliform numbers when solid dairy manure was added to soil compared to compost, N and P inorganic fertilizer and N fertilizer treatments. We did not find any E. coli, Enterococcus or total coliform bacteria on the exterior of the tuber, within the peel or within a whole baked potato after microwave cooking for 5 min.
Water resources in the Wardensville Area, Hardy County, West Virginia, October 2003-May 2004
Evaldi, Ronald D.; McCoy, Kurt J.
2004-01-01
Communities within the Valley and Ridge Physiographic Province of West Virginia are concerned about the availability and sustainability of their water supplies. The water resources of the Wardensville area of West Virginia were investigated and data sources were reviewed that will be useful in similar resource assessments elsewhere in the region. Estimates of long-term average discharge of the Cacapon River, Waites Run, and Trout Run are 170, 21, and 78 cubic feet per second, respectively. Average flow from Wardensville Spring during the study was determined to be 0.265 cubic feet per second, and the apparent age of this water was about 20 years. Increases in springflow and drops in temperature of the water during significant winter runoff events suggest that Wardensville Spring may be under the influence of surface runoff at such times. About 80 total coliform colonies per 100 milliliters (mL) of water were found in the spring, but less than 1 colony per 100 mL of water was fecal coliform, and their source is unknown. A well completed during the study in the Marcellus Shale near the contact with the Oriskany Sandstone is capable of yielding 60 gallons per minute, and water produced from the well has an apparent age of 50 years. Iron and manganese concentrations in the well (1,680 and 114 micrograms per liter, respectively) exceeded the U.S. Environmental Protection Agency secondary maximum contaminant levels. It is likely that a well drilled about 130 feet from Wardensville Spring is hydraulically connected to the spring because pumping at the time of well completion induced drawdown at the spring. About 20 total coliform colonies per 100 mL of water were found in that well, but fecal coliform counts were less than 1 colony per 100 mL of water. Transmissivity values of the aquifer as determined at two wells completed in the Marcellus Shale near the contact with the Oriskany Sandstone on opposite sides of Anderson Ridge are 200 and 400 feet squared per day.
Coliform Bacteria for Bioremediation of Waste Hydrocarbons
2017-01-01
Raw, domestic sewage of Kuwait City contained about 106 ml−1 colony forming units of Enterobacter hormaechei subsp. oharae (56.6%), Klebsiella spp. (36%), and Escherichia coli (7.4%), as characterized by their 16S rRNA-gene sequences. The isolated coliforms grew successfully on a mineral medium with crude oil vapor as a sole source of carbon and energy. Those strains also grew, albeit to different degrees, on individual n-alkanes with carbon chains between C9 and C36 and on the individual aromatic hydrocarbons, toluene, naphthalene, phenanthrene, and biphenyl as sole sources of carbon and energy. These results imply that coliforms, like other hydrocarbonoclastic microorganisms, oxidize hydrocarbons to the corresponding alcohols and then to aldehydes and fatty acids which are biodegraded by β-oxidation to acetyl CoA. The latter is a well-known key intermediate in cell material and energy production. E. coli cells grown in the presence of n-hexadecane (but not in its absence) exhibited typical intracellular hydrocarbon inclusions, as revealed by transmission electron microscopy. Raw sewage samples amended with crude oil, n-hexadecane, or phenanthrene lost these hydrocarbons gradually with time. Meanwhile, the numbers of total and individual coliforms, particularly Enterobacter, increased. It was concluded that coliform bacteria in domestic sewage, probably in other environmental materials too, are effective hydrocarbon-biodegrading microorganisms. PMID:29082238
Retail food safety risks for populations of different races, ethnicities, and income levels.
Signs, Renata J; Darcey, Valerie L; Carney, Trish A; Evans, Alison A; Quinlan, Jennifer J
2011-10-01
Research has found that populations with low socioeconomic status (SES) and minority populations have greater access to small corner markets and less access to supermarkets than high-SES and Caucasian populations. This represents a significant difference in the farm-to-fork continuum that these populations experience. This research examined whether differential retail access to foods results in different food safety risks at the retail level for consumers with different demographics. U.S. Census Bureau census tracts with high African American, Asian, Hispanic, Caucasian, low-SES, and high-SES populations were identified in Philadelphia, PA. Approximately 60 retail food establishments were sampled in each census tract category from June 2008 to June 2010. Food samples collected at stores included milk, eggs, lunchmeat, sandwiches, and ready-to-eat (RTE) fresh fruit, greens, and herbs, when available. With the exception of milk and eggs, only food that had been handled and/or prepared at the retail level was sampled. Food samples were tested for temperature, aerobic plate count, coliforms, fecal coliforms, Escherichia coli, Staphylococcus aureus, and Listeria monocytogenes. The results indicated that internal egg temperatures were higher in samples from low-SES census tracts than in eggs from Caucasian census tracts, and eggs were more often found unrefrigerated in markets in low-SES and Asian census tracts. Milk samples from markets in Hispanic and low-SES census tracts had higher aerobic plate counts than high-SES census tract samples. Sandwiches from markets in high-SES census tracts had higher coliform counts than sandwiches from markets in all other census tract categories. Markets in Asian census tracts had a higher incidence of fecal coliform contamination on sandwiches than markets in Caucasian census tracts. Fecal coliforms were present in a percentage of RTE greens from markets in all census tracts except African American, with the highest percentages of RTE greens positive for fecal coliforms in low-SES (100%), Asian (71.4%), and Caucasian (45.5%) markets.
The ultraviolet absorbance spectrum of coliform bacteria and its relationship to astronomy
NASA Astrophysics Data System (ADS)
Hoyle, F.; Wickramasinghe, N. C.; Jansz, E. R.; Jayatissa, P. M.
1983-09-01
The ultraviolet absorbance spectrum of a mixed culture of coliform bacteria is obtained and compared to recent measurements of the extinction curve of starlight. The absorbance of the bacterial suspensions over the wavebands 3500-2000 A and 7000-3400 A are presented along with a comparison of the extinction values for the star HD 14250 with the alpha function of the coliform suspension, which is a measure of the total amount of the material in the line of sight of the star. The agreement is excellent and is just as good as the agreement obtained by Karim et al. (1983) for typtophan in isolation, supporting the contention that the tryptophan responsible for the astronomical extinction is present in the interstellar grains in protein form.
Endotoxin, coliform, and dust levels in various types of rodent bedding.
Whiteside, Tanya E; Thigpen, Julius E; Kissling, Grace E; Grant, Mary G; Forsythe, Diane
2010-03-01
Endotoxins in grain dust, household dust, and animal bedding may induce respiratory symptoms in rodents and humans. We assayed the endotoxin, coliform, and dust levels in 20 types of rodent bedding. Endotoxin concentrations were measured by using a commercial test kit, coliform counts were determined by using conventional microbiologic procedures, and dust content was evaluated by using a rotating-tapping shaker. Paper bedding types contained significantly less endotoxin than did other bedding types; the highest levels of endotoxin were detected in hardwood and corncob beddings. The range of endotoxin content for each bedding type was: corncob bedding, 1913 to 4504 endotoxin units per gram (EU/g); hardwood bedding, 3121 to 5401 EU/g; corncob-paper mixed bedding, 1586 to 2416 EU/g; and paper bedding, less than 5 to 105 EU/g. Coliform counts varied from less than 10 to 7591 cfu/g in corncob beddings, 90 to 4010 cfu/g in corncob-paper mixed beddings, less than 10 to 137 cfu/g in hardwood beddings, and less than 10 cfu/g in paper beddings. Average dust content was less than 0.15% in all commercial bedding types. We conclude that paper bedding is the optimal bedding type for conducting LPS inhalation studies and that rodent bedding containing high levels of endotoxin may alter the results of respiratory and immunologic studies in rodents.
Endotoxin, Coliform, and Dust Levels in Various Types of Rodent Bedding
Whiteside, Tanya E; Thigpen, Julius E; Kissling, Grace E; Grant, Mary G; Forsythe, Diane B
2010-01-01
Endotoxins in grain dust, household dust, and animal bedding may induce respiratory symptoms in rodents and humans. We assayed the endotoxin, coliform, and dust levels in 20 types of rodent bedding. Endotoxin concentrations were measured by using a commercial test kit, coliform counts were determined by using conventional microbiologic procedures, and dust content was evaluated by using a rotating–tapping shaker. Paper bedding types contained significantly less endotoxin than did other bedding types; the highest levels of endotoxin were detected in hardwood and corncob beddings. The range of endotoxin content for each bedding type was: corncob bedding, 1913 to 4504 endotoxin units per gram (EU/g); hardwood bedding, 3121 to 5401 EU/g; corncob–paper mixed bedding, 1586 to 2416 EU/g; and paper bedding, less than 5 to 105 EU/g. Coliform counts varied from less than 10 to 7591 cfu/g in corncob beddings, 90 to 4010 cfu/g in corncob–paper mixed beddings, less than 10 to 137 cfu/g in hardwood beddings, and less than 10 cfu/g in paper beddings. Average dust content was less than 0.15% in all commercial bedding types. We conclude that paper bedding is the optimal bedding type for conducting LPS inhalation studies and that rodent bedding containing high levels of endotoxin may alter the results of respiratory and immunologic studies in rodents. PMID:20353693
Evaluation of the bacteriological quality of ice cream sold at San Jose, Costa Rica.
Windrantz, P; Arias, M L
2000-09-01
The presence of total and fecal coliforms, E. coli, Listeria sp and Salmonella sp. was evaluated in 65 samples of both commercial and homemade ice cream. 37.1% of homemade ice cream and 20% of commercial ice cream did not fulfill the international standard for total coliforms. At the same time 82.9% of home made samples and 56.7% of commercial ones presented fecal coliforms. E. coli was found in 51.4% of home made samples and 26.7% of commercial ones. Sixteen Listeria sp. isolates were obtained, 50% corresponded to Listeria monocytogenes and 50% to L. innocua. The overall presence of L. monocytogenes in ice cream samples was of 12.3% and it was isolated in all cases, from homemade ice cream samples. Salmonella was not isolated from the samples analyzed. Although the results obtained show an important improvement in the quality of ice cream, compared with a previous work done also in Costa Rica, further efforts shall be done, in order to offer safe products to consumers.
Microbioligical Hazard Contamination in Fermented Vegetables Sold in Local Markets in Cambodia.
Chrun, Rithy; Hosotani, Yukie; Kawasaki, Susumu; Inatsu, Yasuhiro
2017-01-01
Fermented vegetables are common part of Cambodian diet. The food safety status for these foods has not been investigated. This study was conducted to evaluate the microbiological hazards that contaminated fermented vegetables. A total of 68 samples of fermented vegetables were purchased randomly from five wet markets in Phnom Penh. The conventional culture methods for microbiological analysis were used. Coliform bacteria (Escherichia coli, Cronobactersakazakii, and Enterobacter spp.), opportunistic non-Entrobacteriaceae, Enterococcus spp., Staphylococcus spp., and Listeria spp. were found in these fermented foods. The highest contamination rate of Enterococcus spp. was 34% of total fermented vegetable samples, followed by Bacillus spp. coliform bacteria and E. coli (31%, 24% and 10%, respectively). The potential foodborne pathogen, C. sakazakii, was identified in one sample. Fermented mixed vegetables showed higher contamination rate of coliform bacteria (50%) than fermented single-type vegetables (13%). The results showed that fermented vegetables sold in wet market are poor in hygiene. The stage in the processing chain where contamination occurred should be identified and basic sanitary practice should be enforced to improve the food safety of fermented vegetables in Cambodia.
Quantification and characterization of greywater from schools.
Alsulaili, Abdalrahman D; Hamoda, Mohamed F
2015-01-01
Survey of schools of different education levels (primary, intermediate and secondary) in Kuwait showed an average greywater generation rate of 7.3 L/p/d and varied in the range of 2.9-16 l/p/d, reflecting the school level of education (i.e. student age). The highest rates were observed for primary schools while the lowest rates were observed in secondary schools where students are more mature and use the water more wisely. The greywater characteristics indicated waste with low chemical oxygen demand (COD) and 5-day biochemical oxygen demand (BOD5) values but relatively high solids, conductivity, and sodium content due to excessive use of hand soap. Total coliform values ranged between 89 and 352 most probable number (MPN)/mL with an average of 196 MPN/mL while no fecal coliform values were detected. Greywater collected from schools is classified as light greywater and contains much lower levels of organic matter and nutrients compared to residential greywater and domestic wastewater. It is suitable for non-potable reuse after minimal treatment since microbial contamination may pose a serious threat to health if greywater comes into contact with humans. It also provides a good opportunity for reuse in toilet flushing since it can be easily collected from wash sinks and fountains, as major sources, and recycled.
Neelam, Taneja; Malkit, Singh; Pooja, Rao; Manisha, Biswal; Shiva, Priya; Ram, Chander; Meera, Sharma
2012-12-01
Acute gastroenteritis due to Vibrio cholerae and Enterotoxigenic E. coli is a common problem faced in the hot and humid summer months in north India. The study was undertaken to evaluate drinking water supplies for fecal coliforms, V. cholerae and Enterotoxigenic E. coli in urban, semiurban and rural areas in and around Chandigarh and correlate with occurrence of acute gastroenteritis occurring from the same region. Drinking water sample were collected from various sources from April to October 2004 from a defined area. Samples were tested for fecal coliforms and E. coli count. E. coli were screened for heat labile toxin (LT) also. Stool samples from cases of acute gastroenteritis from the same region and time were collected and processed for V. cholerae, Enterotoxigenic E. coli (ETEC) and others like Salmonella, Shigella and Aeromonas spp. A total of 364 water samples were collected, (251 semi urban, 41 rural and 72 from urban areas). 116 (31.8%) samples were contaminated with fecal coliforms (58.5% rural, 33.4% semiurban and 11.1% of samples from urban areas). E. coli were grown from 58 samples. Ninety two isolates of E. coli were tested for enterotoxins of which 8 and 24 were positive for LT and ST respectively. V. cholerae were isolated from 2 samples during the outbreak investigation. Stored water samples showed a significantly higher level of contamination and most of Enterotoxigenic E. coli were isolated from stored water samples. A total of 780 acute gastroenteritis cases occurred; 445 from semiurban, 265 rural and 70 from urban areas. Out of 189 stool samples submitted, ETEC were the commonest (30%) followed by V. cholerae (19%), Shigellae (8.4%), Salmonellae (2.1%) and Aeromonas (2.6%). ST-ETEC (40/57) were commoner than LT-ETEC (17/57). In the present study, high levels of contamination of drinking water supplies (32.1%) correlated well with cases of acute gastroenteritis. Majority of cases of acute gastroenteritis occurred in the semi urban corresponding with high level of contamination (33.4%). The highest level of water contamination was seen in rural areas (58.5%) but the number of acute gastroenteritis cases were lesser (33.9%) as ponds were infrequently used for drinking purpose. Safer household water storage and treatment is recommended to prevent acute gastroenteritis, together with point-of-use water quality monitoring.
Kruy, S L; Soares, J L; Ping, S; Sainte-Marie, F F
2001-12-01
A study of the microbiological quality of ice lice creams/sorbets sold on the streets of Phnom Penh city was conducted from April 1996 to April 1997. Socio-demographic and environmental characteristics with two ice/ice creams samples were collected from vendors selected in the city. A total of 105 vendors and 210 ice/ice creams samples were randomly selected for the study period. Ice/ice cream vendors in the streets of Phnom Penh were adults (mean age: 28 years old) with a male predominance (86.5%). Mean educational level of vendors was 5 years with no training in mass catering. Most ice creams and sorbets (81.7%) were made using traditional methods. Microbiological analysis performed in the laboratory of Pasteur Institute of Cambodia indicated the poor bacteriological quality of the samples. The proportions of samples classified unsafe according to microbiological criteria were 83.3% for total bacterial count at 30 degrees C, 70% for total coliforms, 30% for faecal coliforms, 12.2% for Staphylococcus aureus and 1.9% for presence of Salmonella spp. These bacterial results suggest that many other food products sold in the streets may be similarly poor. Safety measures should be undertaken to avoid potential threats. Regulation of the street food sector should be part of a larger strategy for enhanced food safety and environmental quality in the city.
Lei, Xin Jian; Kim, Yong Min; Park, Jae Hong; Baek, Dong Heon; Nyachoti, Charles Martin; Kim, In Ho
2018-03-01
The use of antibiotics as growth promoters in feed has been fully or partially banned in several countries. The objective of this study was to evaluate effects of levan-type fructan on growth performance, nutrient digestibility, faecal shedding of lactic acid bacteria and coliform bacteria, diarrhoea scores, and faecal gas emission in weaning pigs. A total of 144 weaning pigs [(Yorkshire × Landrace) × Duroc] were randomly allocated to four diets: corn-soybean meal-based diets supplemented with 0, 0.1, 0.5, or 1.0 g kg -1 levan-type fructan during this 42-day experiment. During days 0 to 21 and 0 to 42, average daily gain and average daily feed intake were linearly increased (P < 0.01) with increasing dietary levan-type fructan inclusion. The apparent total tract digestibility of dry matter, crude protein, and gross energy were linearly increased (P < 0.001) with increasing dietary levan-type fructan content. With increasing levels of levan-type fructan, faecal lactic acid bacteria counts were linearly increased (P = 0.001). The results indicate that dietary supplementation with increasing levan-type fructan enhanced growth performance, improved nutrient digestibility, and increased faecal lactic acid bacteria counts in weaning pigs linearly. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
Drinking water quality assessment.
Aryal, J; Gautam, B; Sapkota, N
2012-09-01
Drinking water quality is the great public health concern because it is a major risk factor for high incidence of diarrheal diseases in Nepal. In the recent years, the prevalence rate of diarrhoea has been found the highest in Myagdi district. This study was carried out to assess the quality of drinking water from different natural sources, reservoirs and collection taps at Arthunge VDC of Myagdi district. A cross-sectional study was carried out using random sampling method in Arthunge VDC of Myagdi district from January to June,2010. 84 water samples representing natural sources, reservoirs and collection taps from the study area were collected. The physico-chemical and microbiological analysis was performed following standards technique set by APHA 1998 and statistical analysis was carried out using SPSS 11.5. The result was also compared with national and WHO guidelines. Out of 84 water samples (from natural source, reservoirs and tap water) analyzed, drinking water quality parameters (except arsenic and total coliform) of all water samples was found to be within the WHO standards and national standards.15.48% of water samples showed pH (13) higher than the WHO permissible guideline values. Similarly, 85.71% of water samples showed higher Arsenic value (72) than WHO value. Further, the statistical analysis showed no significant difference (P<0.05) of physico-chemical parameters and total coliform count of drinking water for collection taps water samples of winter (January, 2010) and summer (June, 2010). The microbiological examination of water samples revealed the presence of total coliform in 86.90% of water samples. The results obtained from physico-chemical analysis of water samples were within national standard and WHO standards except arsenic. The study also found the coliform contamination to be the key problem with drinking water.
Gutierrez-Banuelos, Hector; Pinchak, William E; Min, Byeng R; Carstens, Gordon E; Anderson, Robin C; Tedeschi, Luis O; Krueger, Wimberley K; Krueger, Nathan A; Lancaster, Phillip A; Gomez, Robynne R
2011-01-01
Pathogenic bacteria attached to the hide or shed in the feces of cattle at slaughter can contaminate carcasses intended to be processed for human consumption. Therefore, new pre-harvest interventions are needed to prevent the carriage and excretion of foodborne pathogens in cattle presented to the processing plant. The objectives of this study were to examine the antimicrobial effects of hydrolysable tannin-rich chestnut and condensed tannin-rich mimosa extracts on bacterial indicators of foodborne pathogens when applied as a hide-intervention and as a feed additive to feedlot cattle. Water (control) or solutions (3 % wt/vol) of chestnut- and mimosa-extract treatments were sprayed (25 mL) at the left costal side of each animal to a 1000 cm² area, divided in four equal quadrants. Hide-swabs samples obtained at pre-, 2-min, 8-h, and 24-h post-spray application were cultured to enumerate Escherichia coli/total coliforms and total aerobic plate counts. In a second experiment, diets supplemented without (controls) or with (1.5 % of diet dry matter) chestnut- or mimosa-extracts were fed during a 42-day experimental feeding period. Weekly fecal samples starting on day 0, and rumen fluid obtained on days 0, 7, 21 or 42 were cultured to enumerate E.coli/total coliforms and Campylobacter. Tannin spray application showed no effect of treatment or post-application-time (P > 0.05) on measured bacterial populations, averaging 1.7/1.8, 1.5/1.6 and 1.5/1.7 (log₁₀CFU/cm²) for E. coli/total coliforms, and 4.0, 3.4 and 4.2 (log₁₀CFU/cm²) in total aerobes for control, chestnut and mimosa treatments, respectively. Mean (± SEM) ruminal E. coli and total coliform concentrations (log(10) CFU/mL) were reduced (P < 0.01) in steers fed chestnut-tannins (3.6 and 3.8 ± 0.1) in comparison with the controls (4.1 and 4.2 ± 0.1). Fecal E. coli concentrations were affected by treatment (P< 0.01), showing the highest values (log₁₀ CFU/g) in fecal contents from mimosa-fed steers compared to controls (5.9 versus 5.6 ± 0.1 SEM, respectively). Total coliforms (log CFU/g) showed the highest values (P < 0.01) in feces from chestnut- and mimosa-fed steers (6.0 and 6.1 ± 0.1 respectively) in comparison with controls (5.7 ± 0.1). Fecal Campylobacter concentrations (log₁₀CFU/g) were affected by treatment (P < 0.05), day (P < 0.001) and their interaction (P < 0.01) with the controls having lower concentrations than chestnut- and mimosa-fed steers (0.4, 1.0, and 0.8 ± 0.3, respectively). It was concluded that under our research conditions, tannins were not effective in decreasing measured bacterial populations on beef cattle hides. Additionally, chestnut tannin reduced E. coli and total coliforms within the rumen but the antimicrobial effect was not maintained in the lower gastrointestinal tract. Further research is necessary to elucidate the possible antimicrobial effects of tannins at site-specific locations of the gastrointestinal tract in beef cattle fed high-grain and high-forage diets.
Omeira, N; Barbour, E K; Nehme, P A; Hamadeh, S K; Zurayk, R; Bashour, I
2006-08-15
Chicken litter is produced in large quantities from all types of poultry raising activities. It is primarily used for land application, thus it is essential to analyze its properties before it is released to the environment. The objective of this study is to compare the microbiological and chemical properties of litter generated from layer and broiler chickens reared under intensive and free-range production systems. The microbiological analysis consisted of the enumeration of total bacteria, total coliforms, Staphylococcus species, Salmonella species and Clostridium perfringens. Chicken litter from layers reared under intensive and free range systems showed lower mean total bacterial count than the litter collected from chicken broilers reared under either of the two systems (P=0.0291). The litter from intensive layers had the lowest mean total coliform counts (P=0.0222) while the lowest Staphylococcus species count was observed in the litter from free-range layers (P=0.0077). The C. perfringens count was the lowest in chicken litter from intensively raised broilers and layers (P=0.0001). The chemical properties of litter from the different chicken types and production systems were compared based on determination of pH, electrical conductivity, carbon, nitrogen, phosphorus, potassium, cadmium and zinc. Litter from free-range broilers showed the highest pH value (P=0.0005); however, the electrical conductivity was higher in the litter from both intensive and free-range layers compared to the litter from both broiler production systems (P=0.0117). Chicken litter from intensive systems had higher nitrogen content than litter from free-range systems (P=0.0000). The total phosphorus was the lowest in free-range broiler litter (P=0.0001), while the total potassium was the lowest in litter from intensively managed broilers (P=0.0000). Zinc appeared higher in litter from layers compared to that from broilers (P=0.0101). The cadmium content was higher in the litter from free-range broilers and layers compared to that in the litter from intensively managed systems (P=0.0439). Staphylococcus species in the litter as well as cadmium concentrations seem to be the most critical parameters presenting risks on the environment and on human health. Based on the lowest coliform counts (an indication of water pollution), the high nutrient levels and the low cadmium values, litter from intensively managed layers appears as the most suitable for application on agricultural soils.
Effects of aeration on water quality from septic system leachfields.
Potts, David A; Görres, Josef H; Nicosia, Erika L; Amador, José A
2004-01-01
We conducted a pilot-scale study at a research facility in southeastern Connecticut to assess the effects of leachfield aeration on removal of nutrients and pathogens from septic system effluent. Treatments consisted of lysimeters periodically aerated to maintain a headspace O(2) concentration of 0.209 mol mol(-1) (AIR) or vented to an adjacent leachfield trench (LEACH) and were replicated three times. All lysimeters were dosed with effluent from a septic tank for 24 mo at a rate of 12 cm d(-1) and subsequently for 2 mo at 4 cm d(-1). LEACH lysimeters had developed a clogging mat, or biomat, 20 mo before the beginning of our study. The level of aeration in the AIR treatment was held constant regardless of loading rate. No conventional biomat developed in the AIR treatment, whereas a biomat was present in the LEACH lysimeters. The headspace of LEACH lysimeters was considerably depleted in O(2) and enriched in CH(4), CO(2), and H(2)S relative to AIR lysimeters. Drainage water from AIR lysimeters was saturated with O(2) and had significantly lower pH, five-day biological oxygen demand (BOD(5)), and ammonium, and higher levels of nitrate and sulfate than LEACH lysimeters regardless of dosing rate. By contrast, significantly lower levels of total N and fecal coliform bacteria were observed in AIR than in LEACH lysimeters only at the higher dosing rate. No significant differences in total P removal were observed. Our results suggest that aeration may improve the removal of nitrogen, BOD(5), and fecal coliforms in leachfield soil, even in the absence of a biomat.
Synder, J W; Mains, C N; Anderson, R E; Bissonnette, G K
1995-01-01
The water quality of 24 rural, domestic groundwater supplies treated with point-of-use, powdered activated carbon (PAC) filters was monitored to determine how such treatment might impact the bacteriological quality of private, residential drinking water supplies. Heterotrophic-plate-count (HPC) and total coliform analyses were performed on raw, PAC-treated, and overnight or stagnant (first-draw) PAC-treated water samples. Densities of HPC bacteria were elevated by 0.86 and 0.20 orders of magnitude for spring and well water systems, respectively, in PAC-treated effluents following overnight stagnation compared with levels in untreated treated effluents. Densities of HPC bacteria in PAC-treated effluents were significantly reduced (P < 0.01) below influent levels, however, after the point-of-use device was flushed for 2 min. While PAC significantly reduced the number of coliforms in product waters (P < 0.01), these indicator organisms were still detected in some effluents. Seasonal variations were evident in microbial counts from spring but not well water systems. It appears that aside from periods following stagnant-water use, such as overnight, PAC treatment does not compromise the bacteriological quality of drinking water obtained from underground sources. PMID:8534096
Patra, Sova; Das, T K; Avila, C; Cabello, V; Castillo, F; Sarkar, D; Lahiri, Susmita; Jana, B B
2012-04-01
The incidence pattern of cadmium tolerance and antibiotics resistance by Escherichia coli was examined periodically from the samples of water, sludge and intestine of fish raised in waste stabilization ponds in a sewage treatment plant. Samples of water and sludge were collected from all the selected ponds and were monitored for total counts of fecal coliform (FC), total coliform (TC) and the population of Escherichia coli, which was also obtained from the intestine of fishes. Total counts of both FC and TC as well as counts of E. coli were markedly reduced from the facultative pond to the last maturation pond. Tolerance limit to cadmium by E. coli tended to decline as the distance of the sewage effluent from the source increased; the effective lethal concentration of cadmium ranged from 0.1 mM in split chamber to 0.05 mM in first maturation pond. E. coli isolated from water, sludge and fish gut were sensitive to seven out of ten antibiotics tested. It appears that holistic functions mediated through the mutualistic growth of micro algae and heterotrophic bacteria in the waste stabilization ponds were responsible for the promotion of water quality and significant reduction of coliform along the sewage effluent gradient.
Enterobacteria identification and detection of diarrheagenic Escherichia coli in a Port Complex
Costa, Clarissa Frota Macatrão; Neto, Valério Monteiro; Santos, Bruno Rafael de Carvalho; Costa, Bruno Rafael Rabelo; Azevedo, Alexandre; Serra, Josilene Lima; Mendes, Hermínio Benítez Rabello; Nascimento, Adenilde Ribeiro; Mendes, Mariana Bonfim Pinto; Kuppinger, Oliver
2014-01-01
The Port Complex of Maranhão (PCM) is the second largest port complex in Brazil, receiving ships with large volumes of ballast water. To evaluate the microbiological quality of its waters, physicochemical parameters (pH and salinity), the number of coliforms (thermotolerants and totals), and the presence of enterobacterias and diarrheagenic Escherichia coli strains were analyzed. In order to identify the presence of E. coli virulence genes target regions of the stx, elt, est, aggR, CVD432, ipaH and eae nucleotide sequences were studied. The presence of totals and thermotolerants coliforms were positive. Analyzing the salinity parameter, a significant increase in total coliforms was observed during the rainy season. We identified the species Escherichia coli, Proteus mirabilis, Citrobacter freundii, Proteus vulgaris, Klebsiella pneumoniae, Klebsiella ozaenae, Morganella morganii, Enterobacter cloacae and Edwardsiella tarda. Out of the 51 E. coli isolated, two were positive for the elt gene and one was positive for the CVD432 sequence, features of enterotoxigenic and enteroaggregative strains, respectively. This study reveals that the PCM is contaminated by enterobacteria and diarrheagenic E.coli thus providing evidence regarding the risk of these bacteria being carried by ships to other countries, and draws attention to the input of fecal bacteria brought by ships in the port waters of Maranhão. PMID:25477930
Derlet, Robert W; Carlson, James R
2004-01-01
To determine the prevalence of coliform and potentially pathogenic bacteria in remote backcountry alpine lakes and streams of national parks in the Sierra Nevada mountains. Water was sampled at 55 predetermined lakes and streams that would stratify the risk, based on sites used by backpackers, sites used by pack animals, and uncontaminated wild areas. Sites were distributed among Kings Canyon (15), Sequoia (17), and Yosemite (23). Water was collected using Millipore bacterial samplers, which provided specific counts of coliform and other bacteria in each water sample and also served as a transport media from the wilderness to the laboratory. On return to the laboratory, bacteria were harvested from the samplers and subjected to specific identification and qualitative analysis using standard microbiology techniques for the analysis of water. Coliform bacteria were detected in 22 of the 55 sites. All of these sites were below areas used by backpackers or pack animals. Thirty-three sites were free of coliforms. These sites included both those used lightly by backpackers and those with no human or domestic animal use. All samples contained expected amounts of normal aquatic bacteria including Pseudomonas, Rahnella aquatilis, Serratia spp, and nonpathogenic species of Yersinia. Most sampling sites in these national parks are free of coliform or pathogenic organisms. Low levels of coliform bacteria are found in some bodies of water where the watershed has been affected by human or pack animal travel.
Modeling seasonal variability of fecal coliform in natural surface waters using the modified SWAT
NASA Astrophysics Data System (ADS)
Cho, Kyung Hwa; Pachepsky, Yakov A.; Kim, Minjeong; Pyo, JongCheol; Park, Mi-Hyun; Kim, Young Mo; Kim, Jung-Woo; Kim, Joon Ha
2016-04-01
Fecal coliforms are indicators of pathogens and thereby, understanding of their fate and transport in surface waters is important to protect drinking water sources and public health. We compiled fecal coliform observations from four different sites in the USA and Korea and found a seasonal variability with a significant connection to temperature levels. In all observations, fecal coliform concentrations were relatively higher in summer and lower during the winter season. This could be explained by the seasonal dominance of growth or die-off of bacteria in soil and in-stream. Existing hydrologic models, however, have limitations in simulating the seasonal variability of fecal coliform. Soil and in-stream bacterial modules of the Soil and Water Assessment Tool (SWAT) model are oversimplified in that they exclude simulations of alternating bacterial growth. This study develops a new bacteria subroutine for the SWAT in an attempt to improve its prediction accuracy. We introduced critical temperatures as a parameter to simulate the onset of bacterial growth/die-off and to reproduce the seasonal variability of bacteria. The module developed in this study will improve modeling for environmental management schemes.
NASA Astrophysics Data System (ADS)
Wuta, M.; Nyamadzawo, G.; Mlambo, J.; Nyamugafata, P.
2016-04-01
In many smallholder farms in sub-Saharan Africa dambos are used for grazing and crop production especially horticultural crops. Increased use of dambos especially for crop production can result in ground and surface water pollution. Ground and surface water quality along a dambo transect in Chihota, Zimbabwe, was investigated between October 2013 and February 2014. The transect was divided into; upland (control), dambo gardens (mid-slope) and the river (valley bottom). Water samples for quality assessment were collected in October 2013 (peak of dry season) and February 2014 (peak of rainy season). The collected water samples were analysed for pH, faecal coliforms, total nitrogen, electrical conductivity, total dissolved solids (TDS), and some selected nutrients (P, K, Ca, Mg, Na, Zn, and Cu). Water pH was 7.0, 6.4 and 6.1 for river water, garden and upland wells respectively. During the wet season total nitrogen (TN) concentrations were 233 mg/L for uplands, 242 mg/L for gardens and 141 mg/L for the river. During the dry season, TN concentrations were all below 20 mg/L, and were not significantly different among sampling stations along the dambo transect. Dry season faecal coliform units (fcu) were significantly different and were 37.2, 30.0 and 5.0 for upland wells, garden wells and river respectively. Wet season faecal coliforms were also significantly different and were 428.5, 258.0 and 479.4 fcu for upland wells, garden wells and river respectively. The other measured physico-chemical parameters also varied with sampling position along the transect. It was concluded that TN and fcu in sampled water varied with season and that wet season concentrations were significantly higher than dry season concentrations. High concentrations of faecal coliforms and total N during the wet season was attributed to increased water movement. Water from upland wells, garden wells and river was not suitable for human consumption according to WHO standards during both the dry and wet seasons.
Brewers dried yeast as a source of mannan oligosaccharides for weanling pigs.
White, L A; Newman, M C; Cromwell, G L; Lindemann, M D
2002-10-01
Brewers dried yeast, a source of mannan oligosaccharides (MOS), was assessed as an alternative to an antimicrobial agent (carbadox) for young pigs in two experiments. The yeast contained 5.2% MOS. Agglutination tests confirmed adsorption of several serovars of E. coli and Salmonella spp. onto the yeast product. In Exp. 1, seven replicates (five pigs per pen) of 22-d-old pigs were fed a nonmedicated basal diet or the basal diet with carbadox (55 mg/kg), yeast (3%), or a combination of 3% yeast and 2% citric acid for 28 d. Carbadox did not improve growth performance. Growth rate and feed intake were depressed (P < 0.05) in pigs fed yeast alone or in combination with acid. Log counts of total coliforms, Escherichia coli, and Clostridium perfringens in feces were not affected by diet, but Bifidobacteria spp. counts were lower (P < 0.05) in pigs fed the yeast + acid diet and lactobacilli counts were higher (P < 0.05) in pigs fed yeast. Fecal pH and VFA concentrations and intestinal morphological traits were not consistently affected by diet. Serum IgG levels were elevated in the yeast + acid (P < 0.01) group. In Exp. 2, the effects of yeast and carbadox additions to the diet on enteric microbial populations in young pigs housed in isolation units were evaluated. Pigs (n = 24) were weaned at 11 d of age (4.1 kg BW) and placed in isolation chambers (two pigs per chamber) equipped with individual air filtering systems and excrement containers. Treatments were a nonmedicated basal diet and the basal diet with 55 mg/kg of carbadox or with 3% yeast. Diets were fed for 29 d, then each pig was orally dosed with approximately 9.5 x 10(8) CFU of E. coli K88. Daily fecal E. coli K88 counts were not different (P > 0.05) among treatments, but fecal shedding of carbadox-resistant coliforms was higher (P < 0.01) during the 9-d period in pigs fed carbadox. Total fecal coliforms were consistently lower throughout the postinoculation period in pigs fed yeast (P < 0.05). Yeast reduced colonization oftotal coliforms in the duodenum,jejunum, cecum, and colon, but it did not have a consistent effect on colonization of E. coli K88. Pigs fed yeast tended (P < 0.10) to have higher serum IgG levels than controls. In these experiments, brewers dried yeast and carbadox had minimal effects on growth, microbial populations, and intestinal health traits of early-weaned pigs, but certain serum immunological traits were enhanced by feeding yeast.
Chemical characteristic of salt fermented meat inoculated with Pediococcus ssp
NASA Astrophysics Data System (ADS)
Pramono, Y. B.; Rahayu, E. S.; Suparmo; Utami, T.; Nurwantoro; Yunianto, V. D.
2018-01-01
The research goal is knowing of the characteristict of salt fermented meat by Pediococcus ssp. There were microbiological, chemical, and off-flavor compound during fermentation. This study was conducted on research of influence of salt-meat fermentation inoculated used starter. They were included microbiological characteristics, and chemical characteristics. Microbiological characteristics observed were total bacteria, number of coliform groups, bacteria producing bioamine, and total lactic acid bacteria. The result showed that decreasing of coliform and bioamine producer bacteria, and total lactic acid bacteria decreased 3 log cycle. While the soluble protein increased of 7-8% and bioamine increased of 5-6 mg/100 g. And then Off-flavour compound, TVN and TMA increased of 36-20 mg/100g and 16-30 mg/100g, respectively. Conclusion of the research that Pedioccoccus ssp. influenced salt fermented meat.
Sattar, Anas A; Jackson, Simon K; Bradley, Graham
2014-03-01
The use of total lipopolysaccharide (LPS) as a rapid biomarker for bacterial pollution was investigated at a bathing and surfing beach during the UK bathing season. The levels of faecal indicator bacteria Escherichia coli (E. coli), the Gram-positive enterococci, and organisms commonly associated with faecal material, such as total coliforms and Bacteroides, were culturally monitored over four months to include a period of heavy rainfall and concomitant pollution. Endotoxin measurement was performed using a kinetic Limulus Amebocyte Lysate (LAL) assay and found to correlate well with all indicators. Levels of LPS in excess of 50 Endotoxin Units (EU) mL(-1) were found to correlate with water that was unsuitable for bathing under the current European regulations. Increases in total LPS, mainly from Gram-negative indicator bacteria, are thus a potential real-time, qualitative method for testing bacterial quality of bathing waters.
Fecal coliform accumulation within a river subject to seasonally-disinfected wastewater discharges.
Mitch, Azalea A; Gasner, Katherine C; Mitch, William A
2010-09-01
As pathogen contamination is a leading cause of surface water impairment, there has been increasing interest in the implications of seasonal disinfection practices of wastewater effluents for meeting water quality goals. For receiving waters designated for recreational use, disinfection during the winter months is often considered unnecessary due to reduced recreational usage, and assumptions that lower temperatures may reduce pathogen accumulation. For a river subject to seasonal disinfection, we sought to evaluate whether fecal coliforms accumulate during the winter to concentrations that would impair river water quality. Samples were collected from municipal wastewater outfalls along the river, as well as upstream and downstream of each outfall during the winter, when disinfection is not practiced, and during the summer, when disinfection is practiced. During both seasons, fecal coliform concentrations reached 2000-5000 CFU/100 mL, nearly an order of magnitude higher than levels targeted for the river to achieve primary contact recreational uses. During the summer, wastewater effluents were not significant contributors to fecal coliform loadings to the river. During the winter, fecal coliform accumulated along the river predominantly due to loadings from successive wastewater outfalls. In addition to the exceedance of fecal coliform criteria within the river, the accumulation of wastewater-derived fecal coliform along the river during the winter season suggests that wastewater outfalls may contribute elevated loads of pathogens to the commercial shellfish operations occurring at the mouth of the river. Reductions in fecal coliform concentrations between wastewater outfalls were attributed to dilution or overall removal. Combining discharge measurements from gauging stations, tributaries and wastewater outfalls to estimate seepage, dilution between wastewater outfalls was estimated, along with the percentage of the river deriving from wastewater outfalls. After accounting for dilution, the residual reductions in fecal coliform concentrations observed between outfalls were attributed to actual fecal coliform removal. The estimated rate of removal of 1.52 d(-1) was significantly higher than die-off rates determined by previous researchers at similarly low temperatures in laboratory batch experiments, indicating the potential importance of other removal mechanisms, such as predation or sedimentation. Copyright © 2010 Elsevier Ltd. All rights reserved.
Worakhunpiset, S; Tharnpoophasiam, P
2009-07-01
Although multiplex PCR amplification condition for simultaneous detection of total coliform bacteria, Escherichia coli and Clostridium perfringens in water sample has been developed, results with high sensitivity are obtained when amplifying purified DNA, but the sensitivity is low when applied to spiked water samples. An enrichment broth culture prior PCR analysis increases sensitivity of the test but the specific nature of enrichment broth can affect the PCR results. Three enrichment broths, lactose broth, reinforced clostridial medium and fluid thioglycollate broth, were compared for their influence on sensitivity and on time required with multiplex PCR assay. Fluid thioglycollate broth was the most effective with shortest enrichment time and lowest detection limit.
Moore, C.R.
1989-01-01
This report presents physical, chemical, and biological data collected at 50 sampling sites on selected streams in Chester County, Pennsylvania from 1969 to 1980. The physical data consist of air and water temperature, stream discharge, suspended sediment, pH, specific conductance, and dissolved oxygen. The chemical data consist of laboratory determinations of total nutrients, major ions, and trace metals. The biological data consist of total coliform, fecal coliform, and fecal streptococcus bacteriological analyses, and benthicmacroinvertebrate population analyses. Brillouin's diversity index, maximum diversity, minimum diversity, and evenness for each sample, and median and mean Brilloiuin's diversity index, standard deviation, and standard error of the mean were calculated for the benthic-macroinvertebrate data for each site.
Hörman, Ari; Hänninen, Marja-Liisa
2006-10-01
In this study we compared the reference membrane filtration (MF) lactose Tergitol-7 (LTTC) method ISO 9308-1:2000 with the MF m-Endo LES method SFS 3016:2001, the defined substrate chromogenic/fluorogenic Colilert 18, Readycult Coliforms and Water Check methods, and ready-made culture media, 3M Petrifilm EC and DryCult Coli methods for the detection of coliforms and Escherichia coli in various water samples. When the results of E. coli detection were compared between test methods, the highest agreement (both tests negative or positive) with the LTTC method was calculated for the m-Endo LES method (83.6%), followed by Colilert 18 (82.7%), Water-Check (81.8%) and Readycult (78.4%), whereas Petrifilm EC (70.6%) and DryCult Coli (68.9%) showed the weakest agreement. The m-Endo LES method was the only method showing no statistical difference in E. coli counts compared with the LTTC method, whereas the Colilert 18 and Readycult methods gave significantly higher counts for E. coli than the LTTC method. In general, those tests based on the analysis of a 1-ml sample (Petrifilm EC and DryCult Coli) showed weak sensitivity (39.5-52.5%) but high specificity (90.9-78.8%).
Irradiation effect on bulgogi sauce for making commercial Korean traditional meat product, bulgogi
NASA Astrophysics Data System (ADS)
Jo, C.; Kim, D. H.; Shin, M. G.; Kang, I. J.; Byun, M. W.
2003-12-01
Gamma-irradiated sauce of bulogogi, Korean traditional meat products, was compared with heat-pasteurized one to enhance its safety, quality, and commercial availability. The sauce is usually sold in refrigerated state with 2-7 days of self-life or heat-sterilized and sold in room temperature for a year. Raw vegetables, fruits and soy sauce for sauce making were highly contaminated by thermophillic microorganisms (totally 2.13×10 6 CFU/g) and coliform bacteria (totally 5.90×10 4 CFU/g) at the initial stage. Heat treatment (100°C for 30 min) was effective to control coliform and microbes counted from Salmonella-Shigella selective agar in the sauce but not on thermophillic microorganisms, resulting in a rapid spoilage after 2 weeks at 20°C. Gamma irradiation reduced the level of thermophillic microorganisms and the spoilage was prevented during storage for 4 weeks at 20°C. Protease activity of the sauce was significantly reduced by heat treatment while was not changed by irradiation at 2.5, 5.0, and 10 kGy. Sensory evaluation showed that the irradiation was better in color than nonirradiated control or heat-treated sample. Results indicate that low dose irradiation (2.5-5.0 kGy) is effective to ensure safety of bulgogi sauce with acceptable sensory quality.
Toys are a potential source of cross-infection in general practitioners' waiting rooms.
Merriman, Eileen; Corwin, Paul; Ikram, Rosemary
2002-01-01
The waiting rooms of general practitioners' surgeries usually have toys provided for children. The level of contamination of these toys and the effectiveness of toy decontamination was investigated in this study. Hard toys from general practitioners' waiting rooms had relatively low levels of contamination, with only 13.5% of toys showing any coliform counts. There were no hard toys with heavy contamination by coliforms or other bacteria. Soft toys were far more likely to be contaminated, with 20% of toys showing moderate to heavy coliform contamination and 90% showing moderate to heavy bacterial contamination. Many waiting-room toys are not cleaned routinely. Soft toys are hard to disinfect and tend to rapidly become recontaminated after cleaning. Conversely, hard toys can be cleaned and disinfected easily. Soft toys in general practitioners' waiting rooms pose an infectious risk and it is therefore recommended that soft toys are unsuitable for doctors' waiting rooms. PMID:11885823
Data on microbiological quality assessment of rural drinking water supplies in Poldasht county.
Yousefi, Mahmood; Saleh, Hossein Najafi; Yaseri, Mehdi; Mahvi, Amir Hossein; Soleimani, Hamed; Saeedi, Zhyar; Zohdi, Sara; Mohammadi, Ali Akbar
2018-04-01
In this research, the villages with water supply systems under the supervision of the Water and Wastewater Company in Poldasht County, Iran in 2015 was studied. 648 samples were taken from 57 villages during 12month period to test for microbial quality according to the latest guidelines of WHO. Fecal coliform, coliform, turbidity, pH and free residual chlorine were analyzed. Also we used linear Regression statistical analysis for collected data. Result of Data showed that 13.6% of the villages under study had contaminated water resources. In 100 percent of the water sample resource the turbidity level was less than Iranian maximum permissible levels (5 NTU). There was a linear relation between the Free residual color and Coliform in different month of follow up ( r = -0.154, P < 0.001). Data suggests water resources should be comprehensively planned and monitored keeping in view the WHO recommended parameters.
NASA Astrophysics Data System (ADS)
Riyanto; Agustiningsih, W. A.
2018-04-01
Disinfection of coliform and E. Coli in water has been performed by electrolysis using carbon electrodes. Carbon electrodes were used as an anode and cathode with a purity of 98.31% based on SEM-EDS analysis. This study was conducted using electrolysis powered by electric field using carbon electrode as the anode and cathode. Electrolysis method was carried out using variations of time (30, 60, 90, 120 minutes at a voltage of 5 V) and voltage (5, 10, 15, 20 V for 30 minutes) to determine the effect of the disinfection of the bacteria. The results showed the number of coliform and E. coli in water before and after electrolysis was 190 and 22 MPN/100 mL, respectively. The standards quality of drinking water No. 492/Menkes/Per/IV/2010 requires the zero content of coliform and E. Coli. Electrolysis with the variation of time and potential can reduce the number of coliforms and E. Coli but was not in accordance with the standards. The effect of hydrogen peroxide (H2O2) to the electrochemical disinfection was determined using UV-Vis spectrophotometer. The levels of H2O2 formed increased as soon after the duration of electrolysis voltage but was not a significant influence to the mortality of coliform and E.coli.
Patterns and sources of fecal coliform bacteria in three streams in Virginia, 1999-2000
Hyer, Kenneth; Moyer, Douglas
2003-01-01
Surface-water impairment by fecal coliform bacteria is a water-quality issue of national scope and importance. In Virginia, more than 175 stream segments are on the Commonwealth's 1998 303(d) list of impaired waters because of elevated concentrations of fecal coliform bacteria. These fecal coliform-impaired stream segments require the development of total maximum daily load (TMDL) and associated implementation plans, but accurate information on the sources contributing these bacteria usually is lacking. The development of defendable fecal coliform TMDLs and management plans can benefit from reliable information on the bacteria sources that are responsible for the impairment. Bacterial source tracking (BST) recently has emerged as a powerful tool for identifying the sources of fecal coliform bacteria that impair surface waters. In a demonstration of BST technology, three watersheds on Virginia's 1998 303(d) list with diverse land-use practices (and potentially diverse bacteria sources) were studied. Accotink Creek is dominated by urban land uses, Christians Creek by agricultural land uses, and Blacks Run is affected by both urban and agricultural land uses. During the 20-month field study (March 1999?October 2000), water samples were collected from each stream during a range of flow conditions and seasons. For each sample, specific conductance, dissolved oxygen concentration, pH, turbidity, flow, and water temperature were measured. Fecal coliform concentrations of each water sample were determined using the membrane filtration technique. Next, Escherichia coli (E. coli) were isolated from the fecal coliform bacteria and their sources were identified using ribotyping (a method of 'genetic fingerprinting'). Study results provide enhanced understanding of the concentrations and sources of fecal coliform bacteria in these three watersheds. Continuum sampling (sampling along the length of the streams) indicated that elevated concentrations of fecal coliform bacteria (maximum observed concentration of 290,000 colonies/100 milliliters (col/100mL) could occur along the entire length of each stream, and that the samples collected at the downstream monitoring station of each stream were generally representative of the entire upstream reach. Seasonal patterns were observed in the base-flow fecal coliform concentrations of all streams; concentrations were typically highest in the summer and lowest in the winter. Fecal coliform concentrations were lowest during periods of base flow (typically 200?2,000 col/100mL) and increased by 3?4 orders of magnitude during storm events (as high as 700,000 col/100mL). Multiple linear regression models were developed to predict fecal coliform concentrations as a function of streamflow and other water-quality parameters. The source tracking technique provided identification of bacteria contributions from diverse sources that included (but were not limited to) humans, cattle, poultry, horses, dogs, cats, geese, ducks, raccoons, and deer. Seasonal patterns were observed in the contributions of cattle and poultry sources. There were relations between the identified sources of fecal coliform bacteria and the land-use practices within each watershed. There were only minor differences in the distribution of bacteria sources between low-flow periods and high-flow periods. A coupled approach that utilized both a large available source library and a smaller, location-specific source library provided the most success in identifying the unknown E. coli isolates. BST data should provide valuable support and guidance for producing more defendable and scientifically rigorous watershed models. Incorporation of these bacteria-source data into watershed management strategies also should result in the selection of more efficient source-reduction scenarios for improving water quality.
Synergistic effect of solar radiation and solar heating to disinfect drinking water sources.
Rijal, G K; Fujioka, R S
2001-01-01
Waterborne diseases are still common in developing countries as drinking water sources are contaminated and feasible means to reliably treat and disinfect these waters are not available. Many of these developing countries are in the tropical regions of the world where sunlight is plentiful. The objective of this study was to evaluate the effectiveness of combining solar radiation and solar heating to disinfect contaminated water using a modified Family Sol*Saver System (FSP). The non-UV transmittable cover sheet of the former FSP system was replaced with an UV transmittable plastic cover sheet to enable more wavelengths of sunlight to treat the water. Disinfection efficiency of both systems was evaluated based on reduction of the natural populations of faecal coliform, E. coli, enterococci, C. perfringens, total heterotrophic bacteria, hydrogen sulphide producing bacteria and FRNA virus. The results showed that under sunny and partly sunny conditions, water was heated to critical temperature (60 degrees C) in both the FSP systems inactivating more than 3 log (99.9%) of the concentrations of faecal coliform and E. coli to undetectable levels of < 1 CFU/100 mL within 2-5 h exposure to sunlight. However, under cloudy conditions, the two FSP systems did not reduce the concentrations of faecal indicator bacteria to levels of < 1 CFU/100 mL. Nonetheless, sufficient evidence was obtained to show that UV radiation of sunlight plus heat worked synergistically to enhance the inactivation of faecal indicator bacteria. The relative log removal of indicator microorganism in the FSP treated water was total heterotrophic bacteria < C. perfringens < F RNA virus < enterococci < E. coli < faecal coliform. In summary, time of exposure to heat and radiation effects of sunlight were important in disinfecting water by solar units. The data indicated that direct radiation of sunlight worked synergistically with solar heating of the water to disinfect the water. Thus, effective disinfection was observed even when the water temperature did not reach 60 degrees C. Finally, the hydrogen sulphide test is a simple and reliable test that householders can use to determine whether their water had been sufficiently disinfected.
Disinfection of secondary effluents by infiltration percolation.
Makni, H
2001-01-01
Among the most attractive applications of reclaimed wastewater are: irrigation of public parks, sports fields, golf courses and market gardening. These uses require advanced wastewater treatment including disinfection. According to WHO guidelines (1989) and current rules and regulations in Tunisia, faecal coliform levels have to be reduced to < 10(3) or 10(2) CFU/100 mL. In Tunisia, most wastewater plants are only secondary treatment and, in order to meet health related regulations, the effluents need to be disinfected. However, it is usual for secondary effluents to need filtration prior to disinfection. Effectiveness of conventional disinfection processes, such as chlorination and UV radiation, are dependent upon the oxidation level and the levels of suspended solids of the treated water. Ozonation is relatively expensive and energy consuming. The consideration of the advantages and disadvantages of conventional techniques, their reliability, investment needs and operational costs will lead to the use of less sophisticated alternative techniques for certain facilities. Among alternative techniques, soil aquifer treatment and infiltration percolation through sand beds have been studied in Arizona, Israel, France, Spain and Morocco. Infiltration percolation plants have been intermittently fed with secondary or high quality primary effluents which percolated through 1.5-2 m unsaturated coarse sand and were recovered by under-drains. In such infiltration percolation facilities, microorganisms were eliminated through numerous physical, physicochemical and biological inter-related processes (mechanical filtration, adsorption and microbial degradation respectively). Efficiency of faecal coliform removal was dependent upon the water detention times in the filtering medium and on the oxidation of the filtered water. Effluents of Sfax town aerated ponds were infiltrated through 1.5 m deep sand columns in order to determine the performance of infiltration percolation in the polishing of secondary effluents. Elimination of bacteria (total and coliforms, faecal streptococci) and their relationship with the hydraulic load and the temperature were investigated.
Tacker, M; Hametner, C; Wepner, B
2002-01-01
Packaging materials are often considered a critical control point in HACCP systems of food companies. Methods for the determination of the microbial contamination rate of plastic cups, especially for dairy products, must reliably detect single moulds, yeasts or coliforms. In this study, a comparison of a specially adapted coating method, impedance method, direct inoculation and membrane filter technique was carried out to determine contamination with yeasts, moulds, coliforms and total bacterial counts using the appropriate agar in each case. The coating method is recommended for determining yeasts, moulds and coliforms as it allows the localization of the microorganisms as well as the determination of single microorganisms. For total bacterial count, a direct inoculation technique is proposed. The employing of simple measures in the production and during transport of packaging materials, such as dust-prevention or tight sealing in polyethylene bags, heavily reduces microbial contamination rates of packaging material. To reduce contamination rates further, electron beam irradiation was applied: plastic cups sealed in polyethylene bags were treated with 4-5 kGy, a dose that already leads to sterile polystyrene and polypropylene cups without influencing mechanical characteristics of the packaging material.
ERIC Educational Resources Information Center
Omarova, Mariya N.; Orakbay, Lyazzat Zh.; Shuratov, Idelbay H.; Kenjebayeva, Asiya T.; Zhumagalieva, Aizhan B.; Sarsenova, Ainur B.
2016-01-01
The paper is devoted to monitoring the environmental coliform bacteria (CB) contamination (soil and water) in the environmental disaster areas in the Kazakhstan part of the Aral Sea Region and ranking districts by their level of contamination and the rate of gastrointestinal infections (GI). The research was done in environmental disaster areas…
Influence of storage and preservation on microbiological quality of silo ovine milk.
de Garnica, M L; Santos, J A; Gonzalo, C
2011-04-01
This study was designed to analyze the effects of the storage and preservation conditions on counts of mesophilic, thermoduric, psychotrophic, coliform, Escherichia coli, Streptococcus agalactiae, and Staphylococcus aureus organisms in silo ovine milk. A total of 910 analytical determinations were conducted from aliquots of 10 silo ovine milks. The conditions tested were unpreserved and azidiol-preserved milk stored at 4°C, and unpreserved milk stored at -20°C. Milk aged 2, 24, 48, 72, and 96 h post-collection for refrigerated aliquots, and 7, 15, and 30 d post-collection for frozen aliquots. The factors silo and storage conditions significantly contributed to variation of all microbiological variables, although milk age effect within storage was only significant for mesophilic, psychrotrophic, and coliform bacteria counts. In refrigerated raw milk, mesophile, psychrotroph, and coliform counts significantly increased over 96 h post-collection, whereas the other groups and bacteria species tested maintained their initial concentration. In all cases, azidiol preservation maintained the initial bacterial concentration in raw sheep milk under refrigeration throughout 96 h. Thus, azidiol was a suitable preservative for microbiological studies in sheep milk. Smallest counts were registered for frozen samples, particularly for coliforms, E. coli, Strep. agalactiae and Staph. aureus. Estimates of mesophilic, thermoduric and psychrotrophic organisms showed similar values on both azidiol-preserved and frozen milk samples. Coliforms and E. coli counts significantly decrease over time after freezing. Consequently, freezing at -20°C could also be appropriate for analysis of mesophilic, thermoduric, and psychrotrophic bacterial groups, but not for coliforms or mammary pathogens. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Blanch, A R; Galofré, B; Lucena, F; Terradillos, A; Vilanova, X; Ribas, F
2007-03-01
To compare the bacterial coliforms detected from occurrences in three zones of a water distribution system supplied by two separate water sources. Conventional and standardized protocols for identifying enterobacterial populations were applied. Additional tests to confirm isolates were included. Analyses of diversity and population similarity were performed using the Phene Plate System, a miniaturized biochemical phenotyping method. Isolates were identified by the API 20E system in tandem with biochemical phenotyping. A total of 16 576 samples were taken from the water distribution system, with 1416 isolates analysed. A low number of coliform occurrences were observed (2%). Escherichia coli was not detected in either water origin or in Zone 2 samples; however, in Zones 1 and 3 a low number of cases of E. coli were recorded. The percentages of E. coli depended on the identification criteria. Eight biochemical profiles for coliform populations were defined according to the results of the confirmative tests. There was a high diversity among these populations in the three zones studied, although no significant variations in their composition (associated with occurrences in the different zones) were observed. Klebsiella oxytoca was the most commonly detected species irrespective of zone, although seven other enterobacterial genera were also found. Analysis of the enzymatic activity of beta-glucuronidase or application of the criteria established in the norm ISO 9308-1, in tandem with thermotolerance was needed to evaluate the occurrence of E. coli in the distribution systems. Detected occurrences of bacterial coliforms could be associated with re-growth patterns for specific sampling points in the distribution system. Seasonal differences, independent of the studied zones, were observed. Biochemical phenotyping of bacterial coliforms was shown to be a useful method on the characterization of occurrences in water distribution systems.
Water treatment plants assessment at Talkha power plant.
El-Sebaie, Olfat D; Abd El-Kerim, Ghazy E; Ramadan, Mohamed H; Abd El-Atey, Magda M; Taha, Sahr Ahmed
2002-01-01
Talkha power plant is the only power plant located in El-Mansoura. It generates electricity using two different methods by steam turbine and gas turbine. Both plants drew water from River Nile (208 m3 /h). The Nile raw water passes through different treatment processes to be suitable for drinking and operational uses. At Talkha power plant, there are two purification plants used for drinking water supply (100 m3/h) and for water demineralization supply (108 m3/h). This study aimed at studying the efficiency of the water purification plants. For drinking water purification plant, the annual River Nile water characterized by slightly alkaline pH (7.4-8), high annual mean values of turbidity (10.06 NTU), Standard Plate Count (SPC) (313.3 CFU/1 ml), total coliform (2717/100 ml), fecal coliform (0-2400/100 ml), and total algae (3 x 10(4) org/I). The dominant group of algae all over the study period was green algae. The blue green algae was abundant in Summer and Autumn seasons. The pH range, and the annual mean values of turbidity, TDS, total hardness, sulfates, chlorides, nitrates, nitrites, fluoride, and residual chlorine for purified water were in compliance with Egyptian drinking water standards. All the SPC recorded values with an annual mean value of 10.13 CFU/1 ml indicated that chlorine dose and contact time were not enough to kill the bacteria. However, they were in compliance with Egyptian decree (should not exceed 50 CFU/1 ml). Although the removal efficiency of the plant for total coliform and blue green algae was high (98.5% and 99.2%, respectively), the limits of the obtained results with an annual mean values of 40/100 ml and 15.6 org/l were not in compliance with the Egyptian decree (should be free from total coliform, fecal coliform and blue green algae). For water demineralization treatment plant, the raw water was characterized by slightly alkaline pH. The annual mean values of conductivity, turbidity, and TDS were 354.6 microS/cm, 10.84 NTU, and 214.6 mg/I, respectively. There was an increase in the results of conductivity, turbidity, total hardness, and TDS in carbon filter effluent which was attributed to the desorption of adsorbed ions on the carbon media. The removal efficiencies of turbidity, total hardness, and TDS indicated the high efficiency of the cationic filter. The annual removal efficiencies of conductivity, turbidity, chloride, and TDS proved the efficiency of the anionic filter for removing the dissolved and suspended ions. All of the recorded values of the pH, conductivity, turbidity, chlorides, hardness, and TDS of the mixed bed effluent indicated that the water at this stage was of high quality for boiler feed. The study recommended adjustment of coagulant and residual chlorine doses as well as contact time, and continuous monitoring and maintenance of the different units.
McEgan, Rachel; Mootian, Gabriel; Goodridge, Lawrence D; Schaffner, Donald W; Danyluk, Michelle D
2013-07-01
Coliforms, Escherichia coli, and various physicochemical water characteristics have been suggested as indicators of microbial water quality or index organisms for pathogen populations. The relationship between the presence and/or concentration of Salmonella and biological, physical, or chemical indicators in Central Florida surface water samples over 12 consecutive months was explored. Samples were taken monthly for 12 months from 18 locations throughout Central Florida (n = 202). Air and water temperature, pH, oxidation-reduction potential (ORP), turbidity, and conductivity were measured. Weather data were obtained from nearby weather stations. Aerobic plate counts and most probable numbers (MPN) for Salmonella, E. coli, and coliforms were performed. Weak linear relationships existed between biological indicators (E. coli/coliforms) and Salmonella levels (R(2) < 0.1) and between physicochemical indicators and Salmonella levels (R(2) < 0.1). The average rainfall (previous day, week, and month) before sampling did not correlate well with bacterial levels. Logistic regression analysis showed that E. coli concentration can predict the probability of enumerating selected Salmonella levels. The lack of good correlations between biological indicators and Salmonella levels and between physicochemical indicators and Salmonella levels shows that the relationship between pathogens and indicators is complex. However, Escherichia coli provides a reasonable way to predict Salmonella levels in Central Florida surface water through logistic regression.
McEgan, Rachel; Mootian, Gabriel; Goodridge, Lawrence D.; Schaffner, Donald W.
2013-01-01
Coliforms, Escherichia coli, and various physicochemical water characteristics have been suggested as indicators of microbial water quality or index organisms for pathogen populations. The relationship between the presence and/or concentration of Salmonella and biological, physical, or chemical indicators in Central Florida surface water samples over 12 consecutive months was explored. Samples were taken monthly for 12 months from 18 locations throughout Central Florida (n = 202). Air and water temperature, pH, oxidation-reduction potential (ORP), turbidity, and conductivity were measured. Weather data were obtained from nearby weather stations. Aerobic plate counts and most probable numbers (MPN) for Salmonella, E. coli, and coliforms were performed. Weak linear relationships existed between biological indicators (E. coli/coliforms) and Salmonella levels (R2 < 0.1) and between physicochemical indicators and Salmonella levels (R2 < 0.1). The average rainfall (previous day, week, and month) before sampling did not correlate well with bacterial levels. Logistic regression analysis showed that E. coli concentration can predict the probability of enumerating selected Salmonella levels. The lack of good correlations between biological indicators and Salmonella levels and between physicochemical indicators and Salmonella levels shows that the relationship between pathogens and indicators is complex. However, Escherichia coli provides a reasonable way to predict Salmonella levels in Central Florida surface water through logistic regression. PMID:23624476
NASA Astrophysics Data System (ADS)
Sumarsih, S.; Sulistiyanto, B.; Utama, C. S.
2018-02-01
The aim of the research was to evaluate microbiological quality of Panicum maximum grass silage with addition Lactobacillus sp as starter. The completely randomized design was been used on this research with 4 treaments and 3 replications. The treatments were P0 ( Panicum maximum grass silage without addition Lactobacillus sp ), P1 ( Panicum maximum grass silage with 2% addition Lactobacillus sp), P2 (Panicum maximum grass silage with 4% addition Lactobacillus sp) and P3 (Panicum maximum grass silage with 6% addition Lactobacillus sp).The parameters were microbial populations of Panicum maximum grass silage (total lactic acid bacteria, total bacteria, total fungi, and Coliform bacteria. The data obtained were analyzed variance (ANOVA) and further tests performed Duncan’s Multiple Areas. The population of lactic acid bacteria was higher (P<0.05) and the total bacteria, fungi and Coliform were lower (P<0.05) with addition Lactobacillus sp. Microbiological quality of Panicum maximum grass silage with addition Lactobacillus sp was better than no addition Lactobacillus sp.
Disinfection of low quality wastewaters by ultraviolet irradiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zukovs, G.; Kollar, J.; Monteith, H.D.
1986-03-01
Pilot-scale disinfection of simulated combined sewer overflow (CSO) by ultraviolet light (UV) and by high-rate chlorination were compared. Disinfection efficiency was evaluated over a range of dosages and contact times for fecal coliforms, enterococci, P. Aeruginosa, and Salmonella spp. Fecal coliform were reduced 3.0 to 3.2 logs at a UV dose of approximately 350,000..mu.. W s/cm/sup 2/. High-rate chlorination, at a contact time of 2.0 minutes and total residual chlorine concentration of approximately 25 mg/L (as Cl/sub 2/), reduced fecal coliforms by 4.0 logs. Pathogens were reduced to detection limits by both processes. Neither photoreactivation nor regrowth occurred int hemore » disinfected effluents. The estimated capital costs of CSO disinfection by UV irradiation were consistently higher than for chlorination/dechlorination; operation and maintenance costs were similar. 19 references.« less
Microbiological Quality of the Water used in Agriculture in Sardinia.
Sanna, A; Meloni, B; Ruggeri, A; Succa, S; Sanna, C; Carraro, V; Coroneo, V
2016-01-01
The microbiological quality of the water used in irrigation is crucial for the safety of products, such as fruit and vegetables, especially when destined to be consumed raw. However, the microbiological quality of this water is not defined at a community regulatory level or at a national level. With our present work, we wanted to investigate the microbiological quality of the water used for crop irrigation in various Sardinian provinces. Since in most fields the irrigation water is filtered to remove any impurities, the sample was processed twice - both before and after the filtering process. Furthermore, with the purpose of hypothesising the potential health risks attributable to the consumption of crops from the tested fields, samples of horticultural product were collect. Any eventual seasonal differences in the values of microbial concentration were assessed. Microorganism faecal contamination indicators (Escherichia coli, total coliform and faecal streptococci), but even the presence of the opportunistic pathogen such as Pseudomonas aeruginosa were researched in irrigation water. Total mesophilic counts (TMC) were assessed at 36°C and 22°C. On horticultural products we researched both the indicators of process parameters, such as Escherichia coli, Total mesophilic counts at 30°C, Enterobacteriaceae, Total Psychrophilic counts and Pseudomonas aeruginosa, and pathogens, such as Salmonella spp, Listeria monocytogenes and Yersinia enterocolitica. The number of target microorganisms, when present in irrigation water, was very limited: Escherichia coli, total coliform and faecal streptococci, were detected respectively in 48% and 67% of the water samples tested with average concentration values of 0.9, 1.2 and 1.4 log respectively. In fresh vegetable products, the total mesophilic counts (TMC) were found to have average values of 6.6x107 CFU/g. The average values of Enterobacteriaceae totalled 6.1x105 CFU/g; Escherichia coli was detected in only one sample (curly endive) with a value of 180 CFU/g. The data highlights the high quality of the water and how this contributed to achieving satisfactory quality on prime material. However the use of filters, to eliminate impurities, and reservoirs, may represent a crucial issue, if not managed correctly.
Grey water characterization and treatment for reuse in an arid environment.
Smith, E; Bani-Melhem, K
2012-01-01
Grey water from a university facilities building in Cairo, Egypt was analysed for basic wastewater parameters. Mean concentrations were calculated based on grab samples over a 16-month period. Values for chemical oxygen demand (COD) and nutrients exceeded values reported in a number of other studies of grey water, while coliform counts were also high. A submerged membrane bioreactor (SMBR) system using a hollow fibre ultrafiltration membrane was used to treat the grey water with the aim of producing effluent that meets reuse guidelines for agriculture. A test run for 50 days at constant transmembrane pressure resulted in very good removal for key parameters including COD, total suspended solids (TSS), colour, turbidity, ammonia nitrogen, anionic surfactants, and coliform bacteria. High standard deviations were observed for COD and coliform concentrations for both monthly grab samples and influent values from the 50-day SMBR experiment. SMBR effluent meets international and local guidelines for at least restricted irrigation, particularly as pertains to COD, TSS, and faecal coliforms which were reduced to mean treated values of 50 mg/L, 0 mg/L (i.e., not detected), and <50 cfu/100 mL, respectively.
Ultraviolet (UV) disinfection of grey water: particle size effects.
Winward, G P; Avery, L M; Stephenson, T; Jefferson, B
2008-02-01
The impact of water quality on the ultraviolet (UV) disinfection of grey water was investigated with reference to urban water reuse. Direct UV disinfection of grey water did not meet the stringent California State Title 22 criteria for unrestricted urban water reuse due to the presence of particulate material ranging from < 1 to > or = 2000 microm in size. Grey water was manipulated by settling to produce fractions of varying particle size distributions and blending was employed post-disinfection to extract particle-associated coliforms (PACs). The efficacy of UV disinfection was found to be linked to the particle size of the grey water fractions. The larger particle size fractions with a mean particle size of 262 microm and above were observed to shield more coliforms from UV light than did the smaller particles with a mean particle size below 119 microm. Up to 70% of total coliforms in the larger particle size fractions were particle-associated following a UV dose (fluence) of 260 mJ.cm(-2) and would remain undetected by standard coliform enumeration techniques. Implications for urban water reuse are discussed and recommendations made for grey water treatment to ensure removal of particle-associated indicator bacteria and pathogens prior to UV disinfection.
Tsega, N; Sahile, S; Kibret, M; Abera, B
2013-12-01
Accesses to safe water is a universal need however, many of the world's population lack access to adequate and safe water. Consumption of water contaminated causes health risk to the public and the situation is serous in rural areas. To assess the bacteriological and physico-chemical quality of drinking water sources in a rural community of Ethiopia. Water samples were collected from tap, open springs, open dug wells and protected springs for bacteriological analysis of total coliforms and thermotolerant coliforms. The turbidity, pH and temperature were measured immediately after collection. Most drinking water sources were found to have coliform counts above the recommended national and international guidelines and had high sanitary risk scores. There was a statistically significant difference among water sources with respect to TC and TTC (p < 0.05) and there was a statistically significant positive correlation between coliform counts and sanitary risk scores (p < 0.01). Most water sources didn't satisfy the turbidity values recommended by WHO. The water sources were heavily contaminated which suggested poor protection and sanitation practice in the water sources. Source protection strategies as well as monitoring are recommend for this community.
1980-01-01
In a multi-laboratory trial with the membrane filtration technique, three surfactants--Teepol 610 (T610), Tergitol 7 (T7) and sodium lauryl sulphate (LS)--were compared in media for the enumeration of coliform organisms and Escherichia coli in water. A total of 179 samples of water (87 raw and 92 marginally chlorinated) were examined for colony counts of coliform organisms, and 185 water samples (94 raw and 91 marginally chlorinated) for E. coli. Slight differences in the confirmed colony counts between the three media were noted, but few of these were observed consistently in every laboratory. In most laboratories, T7 gave slightly higher counts of E. coli than LS with chlorinated waters; a higher incidence of false-positive results for E. coli at 44 degrees C was also noted with T7. As there were no outstanding differences in the trial, sodium lauryl sulphate, which is chemically defined, cheap and readily available, is therefore recommended for use at a concentration of 0 . 1% instead of Teepol 610 in the standard medium for the enumeration of coliform organisms and E. coli in water by the membrane filtration technique. PMID:7005324
[Super sweet corn hybrids adaptability for industrial processing. I freezing].
Alfonzo, Braunnier; Camacho, Candelario; Ortiz de Bertorelli, Ligia; De Venanzi, Frank
2002-09-01
With the purpose of evaluating adaptability to the freezing process of super sweet corn sh2 hybrids Krispy King, Victor and 324, 100 cobs of each type were frozen at -18 degrees C. After 120 days of storage, their chemical, microbiological and sensorial characteristics were compared with a sweet corn su. Industrial quality of the process of freezing and length and number of rows in cobs were also determined. Results revealed yields above 60% in frozen corns. Length and number of rows in cobs were acceptable. Most of the chemical characteristics of super sweet hybrids were not different from the sweet corn assayed at the 5% significance level. Moisture content and soluble solids of hybrid Victor, as well as total sugars of hybrid 324 were statistically different. All sh2 corns had higher pH values. During freezing, soluble solids concentration, sugars and acids decreased whereas pH increased. Frozen cobs exhibited acceptable microbiological rank, with low activities of mesophiles and total coliforms, absence of psychrophiles and fecal coliforms, and an appreciable amount of molds. In conclusion, sh2 hybrids adapted with no problems to the freezing process, they had lower contents of soluble solids and higher contents of total sugars, which almost doubled the amount of su corn; flavor, texture, sweetness and appearance of kernels were also better. Hybrid Victor was preferred by the evaluating panel and had an outstanding performance due to its yield and sensorial characteristics.
Addo, K K; Mensah, G I; Aning, K G; Nartey, N; Nipah, G K; Bonsu, C; Akyeh, M L; Smits, H L
2011-02-01
To investigate the microbiological quality and the presence of antibiotic residues in raw cow milk and in some indigenous milk products produced and marketed by the informal sector in the coastal savannah zone of Ghana. Milk samples were aseptically collected from 224 kraals and samples of 26 indigenous milk products were purchased from processors and retailers. Total plate counts, total coliform counts and the presence of Escherichia coli and E. coli O157:H7 were determined in all 250 samples. Milk samples were also tested for antibiotic residues. Total plate counts exceeded 10⁵ CFU/ml in 45.2% of the samples while coliforms exceeded 10³ CFU/ml in 66.0% and E. coli was detected in 11.2%. E. coli was present in raw cow milk but not in the indigenous products and all E. coli isolates were negative for E. coli O157:H7. Antibiotic residues were detected in 3.1% of the raw cow milk samples. Bulk milk contains unacceptable levels of hygiene indicators and antibiotic residues and is a potential source of milk-borne infections. The detection of E. coli and antibiotic residues raises public health concerns about the safety of fresh unpasteurized cow milk in the coastal savannah zone of Ghana and calls for improved farm hygiene, the need for milk pasteurization and the sensible use of antibiotics in the milk industry. © 2010 Blackwell Publishing Ltd.
Graham, Jay P; VanDerslice, James
2007-06-01
Many communities along the US-Mexico border remain without infrastructure for water and sewage. Residents in these communities often collect and store their water in open 55-gallon drums. This study evaluated changes in drinking water quality resulting from an intervention that provided large closed water storage tanks (2,500-gallons) to individual homes lacking a piped water supply. After the intervention, many of the households did not change the source of their drinking water to the large storage tanks. Therefore, water quality results were first compared based on the source of the household's drinking water: store or vending machine, large tank, or collected from a public supply and transported by the household. Of the households that used the large storage tank as their drinking water supply, drinking water quality was generally of poorer quality. Fifty-four percent of samples collected prior to intervention had detectable levels of total coliforms, while 82% of samples were positive nine months after the intervention (p < 0.05). Exploratory analyses were also carried out to measure water quality at different points between collection by water delivery trucks and delivery to the household's large storage tank. Thirty percent of the samples taken immediately after water was delivered to the home had high total coliforms (> 10 CFU/100 ml). Mean free chlorine levels dropped from 0.43 mg/l, where the trucks filled their tanks, to 0.20 mg/l inside the household's tank immediately after delivery. Results of this study have implications for interventions that focus on safe water treatment and storage in the home, and for guidelines regarding the level of free chlorine required in water delivered by water delivery trucks.
Mazari-Hiriart, Marisa; López-Vidal, Yolanda; Ponce-de-León, Sergio; Calva, Juan José; Rojo-Callejas, Francisco; Castillo-Rojas, Gonzalo
2005-09-01
In the Mexico City metropolitan area (MCMA), 70% of the water for 18 million inhabitants is derived from the Basin of Mexico regional aquifer. To provide an overview of the quality of the groundwater, a longitudinal study was conducted, in which 30 sites were randomly selected from 1,575 registered extraction wells. Samples were taken before and after chlorine disinfection during both the rainy and dry seasons (2000-2001). Microbiological parameters (total coliforms, fecal coliforms, streptococci, and Vibrio spp.), the presence of Helicobacter pylori, and physicochemical parameters, including the amount of trihalomethanes (THMs), were determined. Although microorganisms and inorganic and organic compounds were evident, they did not exceed current permissible limits. Chlorine levels were low, and the bacterial counts were not affected by chlorine disinfection. Eighty-four bacterial species from nine genera normally associated with fecal contamination were identified in water samples. H. pylori was detected in at least 10% of the studied samples. About 40% of the samples surpassed the THM concentration allowed by Mexican and U.S. regulations, with levels of chloroform being high. The quality of the water distributed to the MCMA varied between the rainy and dry seasons, with higher levels of pH, nitrates, chloroform, bromodichloromethane, total organic carbon, and fecal streptococci during the dry season. This study showed that the groundwater distribution system is susceptible to contamination and that there is a need for a strict, year-round disinfection strategy to ensure adequate drinking-water quality. This situation in one of the world's megacities may reflect what is happening in large urban centers in developing countries which rely on a groundwater supply.
Mazari-Hiriart, Marisa; López-Vidal, Yolanda; Ponce-de-León, Sergio; Calva, Juan José; Rojo-Callejas, Francisco; Castillo-Rojas, Gonzalo
2005-01-01
In the Mexico City metropolitan area (MCMA), 70% of the water for 18 million inhabitants is derived from the Basin of Mexico regional aquifer. To provide an overview of the quality of the groundwater, a longitudinal study was conducted, in which 30 sites were randomly selected from 1,575 registered extraction wells. Samples were taken before and after chlorine disinfection during both the rainy and dry seasons (2000-2001). Microbiological parameters (total coliforms, fecal coliforms, streptococci, and Vibrio spp.), the presence of Helicobacter pylori, and physicochemical parameters, including the amount of trihalomethanes (THMs), were determined. Although microorganisms and inorganic and organic compounds were evident, they did not exceed current permissible limits. Chlorine levels were low, and the bacterial counts were not affected by chlorine disinfection. Eighty-four bacterial species from nine genera normally associated with fecal contamination were identified in water samples. H. pylori was detected in at least 10% of the studied samples. About 40% of the samples surpassed the THM concentration allowed by Mexican and U.S. regulations, with levels of chloroform being high. The quality of the water distributed to the MCMA varied between the rainy and dry seasons, with higher levels of pH, nitrates, chloroform, bromodichloromethane, total organic carbon, and fecal streptococci during the dry season. This study showed that the groundwater distribution system is susceptible to contamination and that there is a need for a strict, year-round disinfection strategy to ensure adequate drinking-water quality. This situation in one of the world's megacities may reflect what is happening in large urban centers in developing countries which rely on a groundwater supply. PMID:16151096
Izumi, Hidemi; Inoue, Ayano
2018-02-02
The extent of sublethally injured coliform bacteria on shredded cabbage, either rinsed or not rinsed with electrolyzed water, was evaluated during storage in air and high CO 2 controlled atmospheres (5%, 10%, and 15%) at 5°C and 10°C using the thin agar layer (TAL) method. Sublethally injured coliform bacteria on nonrinsed shredded cabbage were either absent or they were injured at a 64-65% level when present. Rinsing of shredded cabbage with electrolyzed water containing 25ppm available chlorine reduced the coliform counts by 0.4 to 1.1 log and caused sublethal injury ranging from 42 to 77%. Pantoea ananatis was one of the species injured by chlorine stress. When shredded cabbage, nonrinsed or rinsed with electrolyzed water, was stored in air and high CO 2 atmospheres at 5°C for 7days and 10°C for 5days, coliform counts on TAL plates increased from 3.3-4.5 to 6.5-9.0 log CFU/g during storage, with the increase being greater at 10°C than at 5°C. High CO 2 of 10% and 15% reduced the bacterial growth on shredded cabbage during storage at 5°C. Although injured coliform bacteria were not found on nonrinsed shredded cabbage on the initial day, injured coliforms at a range of 49-84% were detected on samples stored in air and high CO 2 atmospheres at 5°C and 10°C. Injured cells were detected more frequently during storage at both temperatures irrespective of the CO 2 atmosphere when shredded cabbage was rinsed with electrolyzed water. These results indicated that injured coliform bacteria on shredded cabbage, either rinsed or not rinsed with electrolyzed water, exhibited different degrees of injury during storage regardless of the CO 2 atmosphere and temperature tested. Copyright © 2017 Elsevier B.V. All rights reserved.
Anthropogenic influence on surface water quality of the Nhue and Day sub-river systems in Vietnam.
Hanh, Pham Thi Minh; Sthiannopkao, Suthipong; Kim, Kyoung-Woong; Ba, Dang The; Hung, Nguyen Quang
2010-06-01
In order to investigate the temporal and spatial variations of 14 physical and chemical surface water parameters in the Nhue and Day sub-river systems of Vietnam, surface water samples were taken from 43 sampling sites during the dry and rainy seasons in 2007. The results were statistically examined by Mann-Whitney U-test and hierarchical cluster analysis. The results show that water quality of the Day River was significantly improved during the rainy season while this was not the case of the Nhue River. However, the river water did not meet the Vietnamese surface water quality standards for dissolved oxygen (DO), biological oxygen demand (BOD(5)), chemical oxygen demand (COD), nutrients, total coliform, and fecal coliform. This implies that the health of local communities using untreated river water for drinking purposes as well as irrigation of vegetables may be at risk. Forty-three sampling sites were grouped into four main clusters on the basis of water quality characteristics with particular reference to geographic location and land use and revealed the contamination levels from anthropogenic sources.
NASA Astrophysics Data System (ADS)
Gamazo, Pablo; Colina, Rodney; Victoria, Matias; Alvareda, Elena; Burutatran, Luciana; Ramos, Julian; Olivera, María; Soler, Joan
2015-04-01
In many areas of Uruguay groundwater is the only source of water for human consumption and for industrial-agricultural economic activities. Traditionally considered as a safe source, groundwater is commonly used without any treatment. The Uruguayan law requires bacteriological (fecal) analysis for most water uses, but virological analyses are not mentioned in the legislation. In the Salto district, where groundwater is used for human consumption and for agricultural activities, bacterial contamination has been detected in several wells but no viruses analysis have been performed. The Republic University (UDELAR), with the support of the National Agency for Research and Innovation (ANII), is studying the incidence of virus and fecal bacteria in groundwater on an intensive agriculture area of the Salto district. An initial screening campaign of 44 wells was performed in which, besides total and fecal coliforms, rotavirus and adenovirus were detected. A subgroup of the screening wells (15) where selected for bimonthly sampling during a year. In accordance with literature results, single well data analysis shows that coliform and viral contamination can be considered as independent variables. However, when spatial data is integrated, coliform and viral contamination show linear correlation. In this work we present the survey results, we analyse the temporal incidence of variables like precipitation, temperature and chemical composition in well contamination and we discuss the value of coliforms as global indicator of viral contamination for the Salto aquifer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Domek, M.J.; LeChevallier, M.W.; Cameron, S.C.
1984-08-01
Low levels of copper in chlorine-free distribution water caused injury of coliform populations. Monitoring of 44 drinking water samples indicated that 64% of the coliform population was injured. Physical and chemical parameters were measured, including three heavy metals (Cu, Cd, and Pb). Copper concentrations were important, ranging from 0.007 to 0.54 mg/liter. Statistical analyses of these factors were used to develop a model to predict coliform injury. The model predicted almost 90% injury with a copper concentration near the mean observed value (0.158 mg/liter) in distribution waters. Laboratory studies with copper concentrations of 0.025 and 0.050 mg/liter in an inorganicmore » carbon buffer under controlled conditions of temperature and pH caused over 90% injury within 6 and 2 days, respectively. Studies of the metabolism of injured Escherichia coli cells indicated that the respiratory chain is at least one site of damage in injured cells.« less
Too, Johana Kiplagat; Kipkemboi Sang, Willy; Ng'ang'a, Zipporah; Ngayo, Musa Otieno
2016-08-01
Inadequate protection of water sources, and poor household hygienic and handling practices have exacerbated fecal water contamination in Kenya. This study evaluated the rate and correlates of thermotolerant coliform (TTC) household water contamination in Kericho District, Western Kenya. Culture and multiplex polymerase chain reaction (PCR) techniques were used to characterize TTCs. The disk diffusion method was used for antibiotic susceptibility profiling of pathogenic Escherichia coli. Out of the 103 households surveyed, 48 (46.6%) had TTC contaminated drinking water (TTC levels of >10 cfu/100 mL). Five of these households were contaminated with pathogenic E. coli, including 40% enteroaggregative E. coli, 40% enterotoxigenic E. coli, and 20% enteropathogenic E. coli. All these pathogenic E. coli strains were multidrug resistant to sulfamethoxazole/trimethoprim, ampicillin, tetracycline and ampicillin/sulbactam. Rural household locality, drinking water hand contact, water storage container cleaning practice, hand washing before water withdrawal, water source total coliforms <10 cfu/100 mL, temperature, and free chlorine levels were associated with TTC contamination of household drinking water. Significant proportions of household drinking water in Kericho District are contaminated with TTCs including with pathogenic multidrug-resistant E. coli. Source and household hygiene and practices contribute significantly to drinking water contamination.
2010-01-01
Sorbitol-fermenting Bifidobacteria (SFB) proved to be an excellent indicator of very recent human faecal pollution (hours to days) in the investigated tropical stream and groundwater habitats. SFB were recovered from human faeces and sources potentially contaminated with human excreta. SFB were undetectable in animal faeces and environmental samples not contaminated with human faeces. Microcosm studies demonstrated a rapid die-off rate in groundwater (T90 value 0.6 days) and stream water (T90 value 0.9–1.7 days). Discrimination sensitivity analysis, including E. coli, faecal coliforms, total coliforms and Clostridium perfringens spores, revealed high ability of SFB to distinguish differing levels of faecal pollution especially for streams although high background levels of interfering bacteria can complicate its recovery on the used medium. Due to its faster die-off, as compared to many waterborne pathogens, SFB cannot replace microbiological standard parameters for routine water quality monitoring but it is highly recommendable as a specific and complementary tool when human faecal pollution has to be localized or verified. Because of its exclusive faecal origin and human specificity it seems also worthwhile to include SFB in future risk evaluation studies at tropical water resources in order to evaluate under which situations risks of infection may be indicated. PMID:20375476
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leidy, V.A.; Morris, E.E.
1991-01-01
Shallow groundwater flow systems in karst terrain of northwestern Boone County, Arkansas, are particularly susceptible to contamination. The potential for groundwater contamination probably is greater in the northern one-half of the study area where there are more photolineaments and presumably subsurface fractures. Groundwater samples from 17 springs discharging from the Boone Formation and 17 wells completed in the Cotter Dolomite were analyzed to determine ambient groundwater quality and to document water quality variations. The chemical constituents in groundwater generally did not exceed US Environmental Protection Agency primary or secondary maximum contaminant levels. However, fecal coliform and fecal streptococcus bacteria weremore » detected in most springs and in three wells. One spring, located near an abandoned wood-treatment plant (a designated Superfund site), had maximum iron, manganese, lead, and pentachlorophenol concentration that exceeded US Environmental Protection Agency's primary or secondary maximum contamination levels for drinking water. Water samples collected from selected springs emerging from the Boone Formation exhibited an overall decrease in specific conductance and total alkalinity, calcium, magnesium, sodium, and chloride concentrations and an overall increase in nitrate, fecal coliform, and fecal streptococcus bacteria concentrations 3 to 8 hours after a rainstorm.« less
Bickford, Tammy M.; Lindsey, Bruce D.; Beaver, M.R.
1996-01-01
This report describes the bacteriological results of a ground-water study conducted from 1993 to 1995 as part of the U.S. Geological Survey's National Water-Quality Assessment Program in the Lower Susquehanna River Basin study unit. Water samples collected from 146 household supply wells were analyzed for fecal-indicator organisms including total coliform, fecal coliform, Escherichia coli (E. coli), and fecal streptococcus concentrations. Supporting data used in the interpretations are selected water-quality constituents, well-construction information, and the environmental setting at the well site including land use, physiography, and bedrock type. Water from nearly 70 percent of the wells sampled had total coliform present and thus was not suitable for drinking without treatment. Fecal coliforms were found in water from approximately 25 percent of the sampled wells. E. coli testing was not conducted in 1993. Approximately 30 percent of the 88 sampled wells had waters with E. coli. Fecal streptococcus bacteria was present in water from about 65 percent of the wells sampled. Bacteriological contamination was more likely to occur in water from wells in agricultural areas than in water from wells in forested areas. Water from wells sampled in the Ridge and Valley Physiographic Province was more likely to have bacteria than water from wells in the Piedmont Physiographic Province. Differences in bacterial concentrations among bedrock types are only statistically significant for E. coli. Bacterial concentrations are weakly related to well-age but not to other well characteristics such as the total well depth or the casing length. Relations exist between bacterial concentrations and selected water-quality constituents. Most wells from which water was sampled did not have sanitary seals and very few were grouted. This may have contributed to the number of detections of bacteria. It is uncertain whether the bacteria detected are the result of widespread aquifer contamination or site-specific factors.
Luyckx, K; Millet, S; Van Weyenberg, S; Herman, L; Heyndrickx, M; Dewulf, J; De Reu, K
2016-10-19
Biosecurity measures such as cleaning, disinfection and a vacancy period between production cycles on pig farms are essential to prevent disease outbreaks. No studies have tested the effect of a longer vacancy period on bacterial load in nursery units. The present study evaluated the effect of a 10-day vacancy period in pig nursery units on total aerobic flora, Enterococcus spp., Escherichia coli, faecal coliforms and methicillin resistant Staphylococcus aureus (MRSA). Three vacancy periods of 10 days were monitored, each time applied in 3 units. The microbiological load was measured before disinfection and at 1, 4, 7 and 10 days after disinfection. No significant decrease or increase in E. coli, faecal coliforms, MRSA and Enterococcus spp. was noticed. Total aerobic flora counts were the lowest on day 4 after disinfection (i.e. 4.07 log CFU/625 cm 2 ) (P < 0.05), but the difference with other sampling moments was limited (i.e. 0.6 log CFU/625 cm 2 ) and therefore negligible. Furthermore, this observation on day 4 was not confirmed for the other microbiological parameters. After disinfection, drinking nipples were still mostly contaminated with total aerobic flora (i.e. 5.32 log CFU/625 cm 2 ) and Enterococcus spp. (i.e. 95 % of the samples were positive) (P < 0.01); the feeding troughs were the cleanest location (total aerobic flora: 3.53 log CFU/625 cm 2 and Enterococcus spp.: 50 % positive samples) (P < 0.01). This study indicates that prolonging the vacancy period in nursery units to 10 days after disinfection with no extra biosecurity measures has no impact on the environmental load of total aerobic flora, E. coli, faecal coliforms, MRSA and Enterococcus spp..
Bacteriological quality of drinks from vending machines.
Hunter, P. R.; Burge, S. H.
1986-01-01
A survey on the bacteriological quality of both drinking water and flavoured drinks from coin-operated vending machines is reported. Forty-four per cent of 25 drinking water samples examined contained coliforms and 84% had viable counts of greater than 1000 organisms ml at 30 degrees C. Thirty-one flavoured drinks were examined; 6% contained coliforms and 39% had total counts greater than 1000 organisms ml. It is suggested that the D.H.S.S. code of practice on coin-operated vending machines is not being followed. It is also suggested that drinking water alone should not be dispensed from such machines. PMID:3794325
Amanidaz, Nazak; Zafarzadeh, Ali; Mahvi, Amir Hossein
2015-12-01
This study investigated the interaction between heterotrophic bacteria and coliform, fecal coliforms, fecal streptococci bacteria in water supply networks. This study was conducted during 2013 on water supply distribution network in Aq Qala City, Golestan Province, Northern Iran and standard methods were applied for microbiological analysis. The surface method was applied to test the heterotrophic bacteria and MPN method was used for coliform, fecal coliform and fecal streptococci bacteria measurements. In 114 samples, heterotrophic bacteria count were over 500 CFU/ml, which the amount of fecal coliform, coliform, and fecal streptococci were 8, 32, and 20 CFU/100 ml, respectively. However, in the other 242 samples, with heterotrophic bacteria count being less than 500 CFU/ml, the amount of fecal coliform, coliform, and fecal streptococci was 7, 23, and 11 CFU/100ml, respectively. The relationship between heterotrophic bacteria, coliforms and fecal streptococci was highly significant (P<0.05). We observed the concentration of coliforms, fecal streptococci bacteria being high, whenever the concentration of heterotrophic bacteria in the water network systems was high. Interaction between heterotrophic bacteria and coliform, fecal coliforms, fecal streptococci bacteria in the Aq Qala City water supply networks was not notable. It can be due to high concentrations of organic carbon, bio-films and nutrients, which are necessary for growth, and survival of all microorganisms.
AMANIDAZ, Nazak; ZAFARZADEH, Ali; MAHVI, Amir Hossein
2015-01-01
Background: This study investigated the interaction between heterotrophic bacteria and coliform, fecal coliforms, fecal streptococci bacteria in water supply networks. Methods: This study was conducted during 2013 on water supply distribution network in Aq Qala City, Golestan Province, Northern Iran and standard methods were applied for microbiological analysis. The surface method was applied to test the heterotrophic bacteria and MPN method was used for coliform, fecal coliform and fecal streptococci bacteria measurements. Results: In 114 samples, heterotrophic bacteria count were over 500 CFU/ml, which the amount of fecal coliform, coliform, and fecal streptococci were 8, 32, and 20 CFU/100 ml, respectively. However, in the other 242 samples, with heterotrophic bacteria count being less than 500 CFU/ml, the amount of fecal coliform, coliform, and fecal streptococci was 7, 23, and 11 CFU/100ml, respectively. The relationship between heterotrophic bacteria, coliforms and fecal streptococci was highly significant (P<0.05). We observed the concentration of coliforms, fecal streptococci bacteria being high, whenever the concentration of heterotrophic bacteria in the water network systems was high. Conclusion: Interaction between heterotrophic bacteria and coliform, fecal coliforms, fecal streptococci bacteria in the Aq Qala City water supply networks was not notable. It can be due to high concentrations of organic carbon, bio-films and nutrients, which are necessary for growth, and survival of all microorganisms. PMID:26811820
40 CFR Appendix D to Part 122 - NPDES Permit Application Testing Requirements (§ 122.21)
Code of Federal Regulations, 2012 CFR
2012-07-01
... Coliform Fluoride Nitrate-Nitrite Nitrogen, Total Organic Oil and Grease Phosphorus, Total Radioactivity... dodecylbenzenesulfonate Triethylamine Trimethylamine Uranium Vanadium Vinyl acetate Xylene Xylenol Zirconium [Note 1: The.... Testing and reporting for the pesticide fraction in the Tall Oil Rosin Subcategory (subpart D) and Rosin...
40 CFR Appendix D to Part 122 - NPDES Permit Application Testing Requirements (§ 122.21)
Code of Federal Regulations, 2013 CFR
2013-07-01
... Coliform Fluoride Nitrate-Nitrite Nitrogen, Total Organic Oil and Grease Phosphorus, Total Radioactivity... dodecylbenzenesulfonate Triethylamine Trimethylamine Uranium Vanadium Vinyl acetate Xylene Xylenol Zirconium [Note 1: The.... Testing and reporting for the pesticide fraction in the Tall Oil Rosin Subcategory (subpart D) and Rosin...
40 CFR Appendix D to Part 122 - NPDES Permit Application Testing Requirements (§ 122.21)
Code of Federal Regulations, 2014 CFR
2014-07-01
... Coliform Fluoride Nitrate-Nitrite Nitrogen, Total Organic Oil and Grease Phosphorus, Total Radioactivity... dodecylbenzenesulfonate Triethylamine Trimethylamine Uranium Vanadium Vinyl acetate Xylene Xylenol Zirconium [Note 1: The.... Testing and reporting for the pesticide fraction in the Tall Oil Rosin Subcategory (subpart D) and Rosin...
40 CFR Appendix D to Part 122 - NPDES Permit Application Testing Requirements (§ 122.21)
Code of Federal Regulations, 2010 CFR
2010-07-01
... Coliform Fluoride Nitrate-Nitrite Nitrogen, Total Organic Oil and Grease Phosphorus, Total Radioactivity... dodecylbenzenesulfonate Triethylamine Trimethylamine Uranium Vanadium Vinyl acetate Xylene Xylenol Zirconium [Note 1: The.... Testing and reporting for the pesticide fraction in the Tall Oil Rosin Subcategory (subpart D) and Rosin...
40 CFR Appendix D to Part 122 - NPDES Permit Application Testing Requirements (§ 122.21)
Code of Federal Regulations, 2011 CFR
2011-07-01
... Coliform Fluoride Nitrate-Nitrite Nitrogen, Total Organic Oil and Grease Phosphorus, Total Radioactivity... dodecylbenzenesulfonate Triethylamine Trimethylamine Uranium Vanadium Vinyl acetate Xylene Xylenol Zirconium [Note 1: The.... Testing and reporting for the pesticide fraction in the Tall Oil Rosin Subcategory (subpart D) and Rosin...
Zipf, Mariah Siebert; Pinheiro, Ivone Gohr; Conegero, Mariana Garcia
2016-07-01
One of the main actions of sustainability that is applicable to residential, commercial, and public buildings is the rational use of water that contemplates the reuse of greywater as one of the main options for reducing the consumption of drinking water. Therefore, this research aimed to study the efficiencies of simplified treatments for greywater reuse using slow sand and slow slate waste filtration, both followed by granular activated carbon filters. The system monitoring was conducted over 28 weeks, using analyses of the following parameters: pH, turbidity, apparent color, biochemical oxygen demand (BOD), chemical oxygen demand (COD), surfactants, total coliforms, and thermotolerant coliforms. The system was run at two different filtration rates: 6 and 2 m(3)/m(2)/day. Statistical analyses showed no significant differences in the majority of the results when filtration rate changed from 6 to 2 m(3)/m(2)/day. The average removal efficiencies with regard to the turbidity, apparent color, COD and BOD were 61, 54, 56, and 56%, respectively, for the sand filter, and 66, 61, 60, and 51%, respectively, for the slate waste filter. Both systems showed good efficiencies in removing surfactants, around 70%, while the pH reached values of around 7.80. The average removal efficiencies of the total and thermotolerant coliforms were of 61 and 90%, respectively, for the sand filter, and 67 and 80%, respectively, for the slate waste filter. The statistical analysis found no significant differences between the responses of the two systems, which attest to the fact that the slate waste can be a substitute for sand. The maximum levels of efficiency were high, indicating the potential of the systems, and suggesting their optimization in order to achieve much higher average efficiencies. Copyright © 2016 Elsevier Ltd. All rights reserved.
Ground-Water Quality in the Genesee River Basin, New York, 2005-2006
Eckhardt, David A.V.; Reddy, J.E.; Tamulonis, Kathryn L.
2007-01-01
Water samples were collected from 7 community water system wells and 15 private domestic wells throughout the Genesee River Basin in New York State (downstream from the Pennsylvania border) from October 2005 through March 2006 and analyzed to characterize the chemical quality of ground water in the basin. The wells were selected to represent areas of greatest ground-water use and to provide a representative sampling from the 2,439 square-mile basin area in New York. Samples were analyzed for five physical properties and 226 constituents that included nutrients, major inorganic ions, trace elements, radionuclides, pesticides, volatile organic compounds, and bacteria. The results show that ground water used for drinking water is generally of good quality in the Genesee River Basin, although concentrations of seven constituents exceeded drinking water standards. The cations that were detected in the highest concentrations were calcium, magnesium, and sodium; the anions that were detected in the greatest concentrations were bicarbonate, chloride, and sulfate. The predominant nutrient was nitrate, and nitrate concentrations were greater in samples from sand and gravel aquifers than in samples from bedrock aquifers. The trace elements barium, boron, cobalt, copper, and nickel were detected in every sample; the highest concentrations were barium, boron, chromium, iron, manganese, strontium, and lithium. Fourteen pesticides including seven pesticide degradates were detected in water from 12 of the 22 wells, but none of the concentrations exceeded Maximum Contaminant Levels (MCLs). Eight volatile organic compounds (VOCs) were detected in six samples, but none of the concentrations exceeded MCLs. Seven chemical analytes and three types of bacteria were present in concentrations that exceeded Federal and New York State water-quality standards, which are typically identical. Sulfate concentrations exceeded the U.S. Environmental Protection Agency (USEPA) Secondary Maximum Contaminant Level (SMCL) of 250 milligrams per liter (mg/L) in three samples; the chloride SMCL (250 mg/L) was exceeded in one sample. Sodium concentrations exceeded the USEPA Drinking Water Health Advisory of 60 mg/L in five samples. The SMCL for iron (300 ug/L) was exceeded in 11 filtered samples; the USEPA SMCL for manganese (50 ug/L) was exceeded in 10 filtered samples, and the New York State MCL (300 ug/L) was exceeded in 1 filtered sample. The MCL for aluminum (200 ug/L) was exceeded in 1 sample, and the MCL for arsenic (10 ug/L) was exceeded in 1 sample. Radon-222 exceeded the proposed USEPA MCL of 300 picocuries per liter in 16 samples. Any detection of total coliform or fecal coliform bacteria is considered a violation of New York State health regulations; in this study, total coliform was detected in eight samples; fecal coliform was detected in two samples, and Escherichia coli was detected in one sample.
Mizuochi, Shingo; Nelson, Maria; Baylis, Chris; Green, Becky; Jewell, Keith; Monadjemi, Farinaz; Chen, Yi; Salfinger, Yvonne; Fernandez, Maria Cristina
2016-01-01
The Compact Dry "Nissui" EC method, originally certified by the AOAC Research Institute Performance Test Method(SM) program for enumeration of Escherichia coli and non-E. coli coliforms in raw meat products (Performance Tested Method(SM) 110402), has undergone an evaluation to extend the method's claim to cooked chicken, prewashed bagged shredded iceberg lettuce, frozen cod filets, instant nonfat dry milk powder, and pasteurized milk (2% fat). Compact Dry EC is a ready-to-use dry media sheet containing a cold-soluble gelling agent, selective agents, and a chromogenic medium, which are rehydrated by adding 1 mL diluted sample. E. coli form blue/blue-purple colonies, whereas other coliform bacteria form red/pink colonies. Users can obtain an E. coli count (blue/blue-purple colonies only) and a total coliform count (red/pink plus blue/blue-purple colonies) after 24 ± 2 h of incubation at 37 ± 1°C. The matrix extension study was organized by Campden BRI (formerly Campden and Chorleywood Food Research Association Technology, Ltd), Chipping Campden, United Kingdom. Method comparison data for cooked chicken, prewashed bagged shredded iceberg lettuce, frozen cod filets, and instant nonfat dry milk powder were collected in a single-laboratory evaluation by Campden BRI. A multilaboratory study was conducted on pasteurized milk (2% fat), with 13 laboratories participating. The Compact Dry EC method was compared to ISO 16649-2:2001 "Microbiology of food and animal feeding stuffs-Horizontal method for the enumeration of beta-glucuronidase-positive Escherichia coli-Part 2: Colony-count technique at 44 degrees C using 5-bromo-4-chloro-3-indolyl beta-D-glucuronide" and to ISO 4832:2006 "Microbiology of food and animal feeding stuffs-Horizontal method for the enumeration of coliforms-Colony-count technique," the current standards at the time of this study. Each matrix was evaluated separately for E. coli and non-E. coli coliforms at each contamination level (including an uncontaminated level). In the single-laboratory evaluation (cooked chicken, prewashed bagged shredded iceberg lettuce, frozen cod filets, and instant nonfat dry milk powder), colony counts were logarithmically transformed, and then the data were analyzed at each level for sr, RSDr, and mean difference between methods with 95% confidence intervals (CIs). A CI outside a range of -0.5 to 0.5 on the log10 mean difference between methods was used as the criterion to establish a significant statistical difference. In the multilaboratory study on pasteurized milk, after logarithmic transformation, the data were analyzed for sR and RSDR in addition to sr, RSDr, and mean difference with 95% CIs. Regression analysis was performed on all matrixes and reported as r(2). In the single-laboratory evaluation, statistical differences were indicated between the Compact Dry EC and ISO 16649-2 methods for the enumeration of E. coli in two of five contamination levels tested for lettuce, and in the low contamination level for cooked chicken. For the cooked chicken and lettuce at the low level, only a few colonies were recovered for each method, and thus not a true indication of the methods' performance. For the high contamination level of lettuce, counts varied within the sets of five replicates more than 10-fold for each method, which may have contributed to the significant difference. Statistical differences were also indicated between the Compact Dry EC and ISO 4832 methods for the enumeration of coliforms in two of five contamination levels tested for lettuce, two of five contamination levels of milk powder, and in the low contamination level for frozen fish. For the lowest levels of frozen fish and milk powder, only a few colonies were recovered for each method. For the lettuce and the other level of milk powder, counts varied within the sets of five replicates more than 10-fold for each method, which may have contributed to the significant differences indicated in the those contamination levels. In most cases, mean differences between the Compact Dry EC and International Organization of Standardization (ISO) methods were well below 0.5 log10, and the CIs were within the acceptance criterion (-0.5 to 0.5). The sr and RSDr values were similar for both methods, and r(2) values were >0.92 for all comparisons. In the multilaboratory study, no statistical differences were indicated between the methods. The sr, RSDr, sR, and RSDr values were similar for each method and even slightly smaller in most cases for the Compact Dry EC. The r(2) value was 0.97 in comparison to ISO 16649-2, and 0.99 in comparison to ISO 4832. The Compact Dry EC offers comparable results to the ISO standard plating methods in a space saving, easy-to-use format.
Thermotolerant coliforms are not a good surrogate for Campylobacter spp. in environmental water.
St-Pierre, Karen; Lévesque, Simon; Frost, Eric; Carrier, Nathalie; Arbeit, Robert D; Michaud, Sophie
2009-11-01
This study aimed to assess the importance of quantitatively detecting Campylobacter spp. in environmental surface water. The prevalence and the quantity of Campylobacter spp., thermotolerant coliforms, and Escherichia coli in 2,471 samples collected weekly, over a 2-year period, from 13 rivers and 12 streams in the Eastern Townships, Québec, Canada, were determined. Overall, 1,071 (43%), 1,481 (60%), and 1,463 (59%) samples were positive for Campylobacter spp., thermotolerant coliforms, and E. coli, respectively. There were weak correlations between the weekly distributions of Campylobacter spp. and thermotolerant coliforms (Spearman's rho coefficient = 0.27; P = 0.008) and between the quantitative levels of the two classes of organisms (Kendall tau-b correlation coefficient = 0.233; P < 0.0001). Well water samples from the Eastern Townships were also tested. Five (10%) of 53 samples from private surface wells were positive for Campylobacter jejuni, of which only 2 were positive for thermotolerant coliforms. These findings suggest that microbial monitoring of raw water by using only fecal indicator organisms is not sufficient for assessing the occurrence or the load of thermophilic Campylobacter spp. Insights into the role of environmental water as sources for sporadic Campylobacter infection will require genus-specific monitoring techniques.
NASA Astrophysics Data System (ADS)
Hatha, A. A. Mohamed; Neethu, C. S.; Nikhil, S. M.; Rahiman, K. M. Mujeeb; Krishnan, K. P.; Saramma, A. V.
2015-12-01
The objective of this study was to determine the prevalence of antibiotic resistance among aerobic heterotrophic bacteria and coliform bacteria from water and sediment of Kongsfjord. The study was based on the assumption that arctic fjord environments are relatively pristine and offer very little selection pressure for drug resistant mutants. In order to test the hypothesis, 200 isolates belonging to aerobic heterotrophic bacteria and 114 isolates belonging to coliforms were tested against 15 antibiotics belonging to 5 different classes such as beta lactams, aminoglycosides, quinolones, sulpha drugs and tetracyclines. Resistance to beta lactam and extended spectrum beta lactam (ESBL) antibiotics was considerably high and they found to vary significantly (p < 0.05) between heterotrophic and coliform bacteria. Though the coliforms showed significantly high level of antibiotic resistance against ESBL's extent and diversity of antibiotic resistance (as revealed by multiple antibiotic resistance index and resistance patterns), was high in the aerobic heterotrophic bacteria. Most striking observation was that isolates from fjord sediments (both heterotrophic bacteria and coliforms) in general showed relatively high prevalence of antibiotic resistance against most of the antibiotics tested, indicating to better selection pressure for drug resistance mutants in the fjord sediments.
Castillo, A; Lucia, L M; Goodson, K J; Savell, J W; Acuff, G R
1998-07-01
Cleaning treatments, such as high-pressure water wash at 35 degrees C or trim, alone and combined with sanitizing treatments, such as hot water (95 degrees C at the source), warm (55 degrees C) 2% lactic acid spray, and combinations of these two sanitizing methods, were compared for their effectiveness in reducing inoculated numbers (5.0 to 6.0 log CFU/cm2) of Salmonella typhimurium, Escherichia coli O157:H7, aerobic plate counts, Enterobacteriaceae, total coliforms, thermotolerant coliforms, and generic E. coli on hot beef carcass surface areas in a model carcass spray cabinet. Log reductions in numbers of all tested organisms by water wash or trim alone were significantly smaller than the log reductions obtained by the different combined treatments. Regardless of the cleaning treatment (water wash or trim) or surface area, the range for mean log reductions by hot water was from 4.0 to > 4.8 log CFU/cm2, by lactic acid spray was from 4.6 to > 4.9 log CFU/cm2, by hot water followed by lactic acid spray was from 4.5 to > 4.9 log CFU/cm2, and by lactic acid spray followed by hot water was from 4.4 to > 4.6 log CFU/cm2, for S. typhimurium and E. coli O157:H7. Identical reductions were obtained for thermotolerant coliforms and generic E. coli. No differences in bacterial reductions were observed for different carcass surface regions. Water wash and trim treatments caused spreading of the contamination to other areas of the carcass surface while providing an overall reduction in fecal or pathogenic contamination on carcass surface areas. This relocated contamination after either water wash or trim was most effectively reduced by following with hot water and then lactic acid spray. This combined treatment yielded 0% positive samples for S. typhimurium, E. coli O157:H7, thermotolerant coliforms, and generic E. coli on areas outside the inoculated areas, whereas percent positive samples after applying other combined treatments ranged from 22 to 44% for S. typhimurium, 0 to 44% for E. coli O157:H7, and 11 to 33% for both thermotolerant coliforms and generic E. coli. From data collected in this study, it is possible to choose an effective, inexpensive treatment to reduce bacterial contamination on beef carcasses. In addition, the similar reduction rates of total coliforms, thermotolerant coliforms, or generic E. coli may be useful in identifying an indicator to verify the effectiveness of the selected treatment as a critical control point in a Hazard Analysis and Critical Control Point program.
The decontamination of industrial casein and milk powder by irradiation
NASA Astrophysics Data System (ADS)
Żegota, H.; Małolepszy, B.
2008-09-01
The efficacy of gamma radiation decontamination of industrial casein, a milk protein utilized as a component of many food and non-food products has been studied. Low-fat milk powder was also included with a purpose to study the microflora survival in protein-rich materials. Microbial analysis of the samples prior to irradiation showed that the initial total viable count was higher than 6.0 log cfu g -1 in both casein and milk powders. The contamination of casein with moulds and yeasts was found to be equal to 3.56 log cfu g -1. The counts of coliforms have not exceeded the value of 2.48 log cfu g -1. Radiation processing of casein and milk powder has substantially reduced the microbial population of all samples. The dose of 5 kGy was sufficient to reduce the total microflora and coliforms counts to the level permitted for food products. Survivals of microorganisms were analyzed by the generalized exponential equation, SF =exp[ -D/ Do) α]. Values of an exponent, α, standing for the dispersion parameter, were equal to 0.65 and 0.70 for microorganisms contaminating casein and milk powders, respectively. The numerical value of the dispersion parameter α<1 indicates the concave dependence of a logarithm of surviving fraction versus radiation dose. No difference in microflora survival in irradiated samples tested immediately and in samples stored for 1-month after irradiation has been noticed.
Comparative treatment effectiveness of conventional trench and seepage pit systems.
Field, J P; Farrell-Poe, K L; Walworth, J L
2007-03-01
On-site wastewater treatment systems can be a potential source of groundwater contamination in regions throughout the United States and other parts of the world. Here, we evaluate four conventional trench systems and four seepage pit systems to determine the relative effectiveness of these systems for the treatment of septic tank effluent in medium- to coarse-textured arid and semiarid soils. Soil borings were advanced up to twice the depth of the trenches (4 m) and seepage pits (15 m) at two horizontal distances (30 cm and 1.5 m) from the sidewalls of the systems. Soil samples were analyzed for various biological and chemical parameters, including Escherichia coli, total coliform, pH, total organic carbon, total dissolved solids, total nitrogen, ammonium-nitrogen, and nitrate-nitrogen. Most soil parameters investigated approached background levels more rapidly near the trenches than the seepage pits, as sampling distance increased both vertically and horizontally from the sidewalls of the systems.
Microbiological, coliphages and physico-chemical assessments of the Umgeni River, South Africa.
Singh, Atheesha; Lin, Johnson
2015-01-01
The water quality of Umgeni River in KwaZulu-Natal (South Africa) was investigated from April 2011 to January 2012. Indicator bacterial populations, physico-chemical properties, heavy metal contaminants and the presence of coliphages were determined according to standard protocols. The results showed that all sampling points failed to comply with the set guidelines for turbidity, total coliform, faecal coliform and total heterotrophic counts. Salmonella spp., Shigella spp. and Vibrio cholerae were also detected in all the water samples. The somatic coliphages and F-RNA coliphages were detected more frequently in the lower reaches of the river during summer. Temperature, electrical conductivity and pH were found to have positive relationships with the microbial communities especially in the lower catchment area during spring and summer indicating the impacts of various anthropogenic activities in the surrounding areas.
UV inactivation of pathogenic and indicator microorganisms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, J.C.; Ossoff, S.F.; Lobe, D.C.
1985-06-01
Survival was measured as a function of the dose of germicidal UV light for the bacteria Escherichia coli, Salmonella typhi, Shigella sonnei, Streptococcus faecalis, Staphylococcus aureus, and Bacillus subtilis spores, the enteric viruses poliovirus type 1 and simian rotavirus SA11, the cysts of the protozoan Acanthamoeba castellanii, as well as for total coliforms and standard plate count microorganisms from secondary effluent. The doses of UV light necessary for a 99.9% inactivation of the cultured vegetative bacteria, total coliforms, and standard plate count microorganisms were comparable. However, the viruses, the bacterial spores, and the amoebic cysts required about 3 to 4more » times, 9 times, and 15 times, respectively, the dose required for E. coli. These ratios covered a narrower relative dose range than that previously reported for chlorine disinfection of E. coli, viruses, spores, and cysts.« less
Water quality at points-of-use in the Galapagos Islands.
Gerhard, William A; Choi, Wan Suk; Houck, Kelly M; Stewart, Jill R
2017-04-01
Piped drinking water is often considered a gold standard for protecting public health but research is needed to explicitly evaluate the effect of centralized treatment systems on water quality in developing world settings. This study examined the effect of a new drinking water treatment plant (DWTP) on microbial drinking water quality at the point-of-use on San Cristobal Island, Galapagos using fecal indicator bacteria total coliforms and Escherichia coli. Samples were collected during six collection periods before and after operation of the DWTP began from the freshwater sources (n=4), the finished water (n=6), and 50 sites throughout the distribution system (n=287). This study found that there was a significant decrease in contamination by total coliforms (two orders of magnitude) and E. coli (one order of magnitude) after DWTP operation began (p<0.001). However, during at least one post-construction collection cycle, total coliforms and E. coli were still found at 66% and 28% of points-of-use (n=50), respectively. During the final collection period, conventional methods were augmented with human-specific Bacteroides assays - validated herein - with the goal of elucidating possible microbial contamination sources. Results show that E. coli contamination was not predictive of contamination by human wastes and suggests that observed indicator bacteria contamination may have environmental origins. Together these findings highlight the necessity of a holistic approach to drinking water infrastructure improvements in order to deliver high quality water through to the point-of-use. Copyright © 2017 Elsevier GmbH. All rights reserved.
Microbiological Quality of Seafood Marketed in Taiwan.
Wong, Hin-Chung; Jiang, Huai-Yu; Lin, Hsu-Yang; Wang, Yu-Ting
2015-11-01
Seafood is often associated with foodborne illnesses, and Vibrio parahaemolyticus is the most common pathogen implicated in outbreaks in Taiwan. In this study, the microbiological quality of 300 raw or mixed ready-to-eat (RTE) and other cooking-needed seafood samples was examined. The total aerobic and coliform counts of the RTE samples were significantly higher than those of other cooking-needed samples. On average, 55.8 and 29.7% of the RTE samples failed to meet the local microbiological standards for total aerobic (5 log CFU/g) and coliform (3 log most probable number [MPN] per g), counts respectively; the corresponding percentages for the RTE samples from Taipei City were 9.1 and 18.2%, respectively. The total aerobic and coliform counts in the RTE samples from supermarkets and chain restaurants were significantly lower than those from traditional restaurants. The Vibrio species were more frequently identified in the cooking-needed samples than in RTE samples. Low incidences of V. parahaemolyticus (1.4%), V. vulnificus (1.9%), and V. cholerae (0%) were detected in most RTE samples. High densities of V. parahaemolyticus and V. vulnificus (1,200 MPN/g) were detected in a few RTE samples, only one of which contained toxigenic (tdh(+)) V. parahaemolyticus. The results of this investigation reveal that better hygiene of seafood providers such as chain restaurants, supermarkets, and traditional restaurants in Taipei City would effectively improve the microbiological quality of the seafood. The results will facilitate the establishment of measures for controlling the risks associated with seafood in Taiwan.
NASA Astrophysics Data System (ADS)
Karthe, Daniel; Lin, Pei-Ying; Westphal, Katja
2017-09-01
The Holtemme is a small headwater stream in North Germany's Elbe River Basin. According to German and European legislation, hygienic monitoring is not mandatory for such water bodies which are neither drinking water sources nor categorized as bathing waters. Consequently, relatively little is known about the occurrence of-potentially pathogenic-bacteria and viruses in Germany's streams and rivers. The Holtemme was selected for a case study because it is relatively well monitored for both chemical water quality and aquatic ecology, but not for hygiene. Originating in the mountains of Harz Nature Park, the 47 km long Holtemme is characterized by a strong longitudinal gradient in chemical water quality, which is related to different land uses and the influx of treated wastewater from two urban areas (Wernigerode and Halberstadt). Waste water loads received by the Holtemme are comparatively high when compared to similarly small streams. In 2015, total coliform concentrations between more than 200 and 77,010 bacteria per 100 mL, and fecal coliform concentrations between 5 and 24,060 bacteria per 100 mL were observed in the Holtemme's main channel. The highest concentrations were typically found below the outlets of the two wastewater treatment plants. The treated wastewater contained total and fecal coliform concentrations of up to 200,500 and 83,100 per 100 mL, respectively; however, there were significant temporal variations. While the observed concentrations are unproblematic from a legal perspective (because no maximum permissible limits are defined for streams in Germany), they would exceed the tolerable limits for bathing waters in the EU, indicating moderate to critical pollution limits.
Minimally processed vegetable salads: microbial quality evaluation.
Fröder, Hans; Martins, Cecília Geraldes; De Souza, Katia Leani Oliveira; Landgraf, Mariza; Franco, Bernadette D G M; Destro, Maria Teresa
2007-05-01
The increasing demand for fresh fruits and vegetables and for convenience foods is causing an expansion of the market share for minimally processed vegetables. Among the more common pathogenic microorganisms that can be transmitted to humans by these products are Listeria monocytogenes, Escherichia coli O157:H7, and Salmonella. The aim of this study was to evaluate the microbial quality of a selection of minimally processed vegetables. A total of 181 samples of minimally processed leafy salads were collected from retailers in the city of Sao Paulo, Brazil. Counts of total coliforms, fecal coliforms, Enterobacteriaceae, psychrotrophic microorganisms, and Salmonella were conducted for 133 samples. L. monocytogenes was assessed in 181 samples using the BAX System and by plating the enrichment broth onto Palcam and Oxford agars. Suspected Listeria colonies were submitted to classical biochemical tests. Populations of psychrotrophic microorganisms >10(6) CFU/g were found in 51% of the 133 samples, and Enterobacteriaceae populations between 10(5) and 106 CFU/g were found in 42% of the samples. Fecal coliform concentrations higher than 10(2) CFU/g (Brazilian standard) were found in 97 (73%) of the samples, and Salmonella was detected in 4 (3%) of the samples. Two of the Salmonella-positive samples had <10(2) CFU/g concentrations of fecal coliforms. L. monocytogenes was detected in only 1 (0.6%) of the 181 samples examined. This positive sample was simultaneously detected by both methods. The other Listeria species identified by plating were L. welshimeri (one sample of curly lettuce) and L. innocua (2 samples of watercress). The results indicate that minimally processed vegetables had poor microbiological quality, and these products could be a vehicle for pathogens such as Salmonella and L. monocytogenes.
Upadhaya, Santi Devi; Park, Jae Won; Lee, Jae Hwan; Kim, In Ho
2016-01-01
A study was conducted to determine the efficacy of β-mannanase supplementation to a diet based on corn and soya bean meal (SBM) on growth performance, nutrient digestibility, blood urea nitrogen (BUN), faecal coliforms and lactic acid bacteria, and noxious gas emission in growing pigs. A total of 140 pigs [(Landrace × Yorkshire) × Duroc; average body weight 25 ± 3 kg] were randomly allotted to a 2 × 2 factorial arrangement with dietary treatments consisting of hulled or dehulled SBM without or with supplementation of 400 U β-mannanase/kg. During the 6 weeks of experimental feeding, β-mannanase supplementation had no effect on body weight gain, feed intake and gain:feed (G:F) ratio. Compared with dehulled SBM, feeding hulled SBM caused an increased feed intake of pigs in the entire trial (p = 0.05). The G:F ratio was improved in pigs receiving dehulled SBM (p < 0.05). Dietary treatments did not influence the total tract digestibility of dry matter, nitrogen and gross energy. Enzyme supplementation reduced (p < 0.05) the population of faecal coliforms and tended to reduce the NH3 concentration after 24 h of fermentation in a closed box containing faecal slurry. Feeding hulled SBM tended to reduce NH3 emission on days 3 and 5 of fermentation. In conclusion, mannanase supplementation had no influence on growth performance and nutrient digestibility but showed a positive effect on reducing coliform population and tended to reduce NH3 emission. Dehulled SBM increased G:F ratio and hulled SBM tended to reduce NH3 emission.
Microbiological Implications of Periurban Agriculture and Water Reuse in Mexico City
Mazari-Hiriart, Marisa; Ponce-de-León, Sergio; López-Vidal, Yolanda; Islas-Macías, Pilar; Amieva-Fernández, Rosa Isabel; Quiñones-Falconi, Francisco
2008-01-01
Background Recycled treated or untreated wastewater represents an important health challenge in developing countries due to potential water related microbiological exposure. Our aim was to assess water quality and health implications in a Mexico City periurban agricultural area. Methodology/Principal Findings A longitudinal study in the Xochimilco wetland area was conducted, and 42 sites were randomly selected from 211, including irrigation water canals and effluents of treatment plants. Sample collection took place during rainy and dry seasons (2000–2001). Microbiological parameters (total coliforms, fecal coliforms, streptococci/enterococci, and bacteria other than Vibrio grown on TCBS), Helicobacter pylori, and physicochemical parameters including trihalomethanes (THM) were determined. Fecal coliforms and fecal streptococci are appropriate indicators of human or animal fecal contamination. Fecal coliform counts surpass Mexican and World Health Organization irrigation water guidelines. Identified microorganisms associated with various pathologies in humans and domestic animals comprise Escherichia coli, Klebsiella spp., Salmonella spp., Enterobacter spp., Enterococcus spp., and Pseudomonas spp; H. pylori was also present in the water. An environmental characteristic of the canal system showed high Total Organic Carbon content and relatively low dissolved oxygen concentration; residual chlorine as a disinfection control is not efficient, but THMs do not represent a problem. During the rainy season, temperature and conductivity were higher; in contrast, pH, dissolved oxygen, ammonia, and residual chlorine were lower. This is related with the continuous load of feces from human and animal sources, and to the aquatic systems, which vary seasonally and exhibit evidence of lower water quality in effluents from treatment plants. Conclusions/Significance There is a need for improvement of wastewater treatment systems, as well as more efficient monitoring, regulation, and enforcement procedures for wastewater disposal into bodies of water. PMID:18509453
Microbiological implications of periurban agriculture and water reuse in Mexico City.
Mazari-Hiriart, Marisa; Ponce-de-León, Sergio; López-Vidal, Yolanda; Islas-Macías, Pilar; Amieva-Fernández, Rosa Isabel; Quiñones-Falconi, Francisco
2008-05-28
Recycled treated or untreated wastewater represents an important health challenge in developing countries due to potential water related microbiological exposure. Our aim was to assess water quality and health implications in a Mexico City periurban agricultural area. A longitudinal study in the Xochimilco wetland area was conducted, and 42 sites were randomly selected from 211, including irrigation water canals and effluents of treatment plants. Sample collection took place during rainy and dry seasons (2000-2001). Microbiological parameters (total coliforms, fecal coliforms, streptococci/enterococci, and bacteria other than Vibrio grown on TCBS), Helicobacter pylori, and physicochemical parameters including trihalomethanes (THM) were determined. Fecal coliforms and fecal streptococci are appropriate indicators of human or animal fecal contamination. Fecal coliform counts surpass Mexican and World Health Organization irrigation water guidelines. Identified microorganisms associated with various pathologies in humans and domestic animals comprise Escherichia coli, Klebsiella spp., Salmonella spp., Enterobacter spp., Enterococcus spp., and Pseudomonas spp; H. pylori was also present in the water. An environmental characteristic of the canal system showed high Total Organic Carbon content and relatively low dissolved oxygen concentration; residual chlorine as a disinfection control is not efficient, but THMs do not represent a problem. During the rainy season, temperature and conductivity were higher; in contrast, pH, dissolved oxygen, ammonia, and residual chlorine were lower. This is related with the continuous load of feces from human and animal sources, and to the aquatic systems, which vary seasonally and exhibit evidence of lower water quality in effluents from treatment plants. There is a need for improvement of wastewater treatment systems, as well as more efficient monitoring, regulation, and enforcement procedures for wastewater disposal into bodies of water.
Evaluating greywater reuse potential for sustainable water resources management in Oman.
Jamrah, Ahmad; Al-Futaisi, Ahmed; Prathapar, Sanmugan; Harrasi, Ali Al
2008-02-01
This study aims to evaluate the potential of greywater availability in Muscat Governorate in the Sultanate of Oman, to establish a methodology for greywater quantity estimation, to test greywater quality in order to assess reuse potential, and to examine public acceptance for reuse.Total fresh water consumption and greywater generation from different household sources were measured by water meters in five selected households during summer and winter. Additionally, a survey was designed and conducted in five administrative areas of Muscat Governorate, with the objective of testing a methodology for estimating greywater generation potential in these areas. Collected data were compared with that used by the Ministry of Housing, Electricity and Water, Sultanate of Oman. The survey covered a total of 169 houses and 1,365 people. Greywater samples were collected and analyzed from showers, laundries, kitchens and sinks in some of these households to determine their water quality parameters. Statistical analysis results indicated that there is no significant variance in the total fresh water consumption between data used by the ministry and those measured and estimated during this study, highlighting the applicability of the tested method. The study concluded that the average per capita greywater generation rate is 151 Lpcd. Greywater production ranged from 80 to 83% of the total fresh water consumption and most of the greywater is generated from showers. Further, 55 to 57% of the greywater generated in a typical Omani household originated from the shower, 28 to 33% originated from the kitchen, 6 to 9% originated from laundry, and 5 to 7% originated from sink, which constitutes approximately 81% of the total fresh water consumption. The physical, chemical, and biological analyses of the grab samples revealed that greywater contains significant levels of suspended solids, inorganic constituents, total organic carbon, chemical and biochemical oxygen demands, total Coliforms and Escherichia Coliform bacteria. The public acceptance survey illustrated that approximately 76% of the respondents accepted the reuse of greywater for gardening, 53% for car washing and 66% for toilet flushing.
Delbeke, Stefanie; Ceuppens, Siele; Jacxsens, Liesbeth; Uyttendaele, Mieke
2015-09-02
Enteric pathogens, such as Salmonella spp. and pathogenic Escherichia coli, have been detected and associated with food borne outbreaks from (imported) fresh leafy herbs. Screening on imported herbs from South East Asian countries has been described. However, limited information on prevalence of these pathogens is available from other sourcing regions. Therefore, fresh pre-packed basil and coriander leaves from a Belgian trading company were investigated for the presence of Salmonella spp., Shiga toxin-producing E. coli (STEC), generic E. coli and coliforms. In total 592 samples were collected originating from Belgium, Israel and Cyprus during 2013-2014. Multiplex PCR followed by further culture confirmation was used for the detection of Salmonella spp. and STEC, whereas the Petrifilm Select E. coli and VRBL-agar were used, respectively, for the enumeration of E. coli and coliforms. Salmonella was detected in 10 out of 592 samples (25g) (1.7%; 5 from basil and 5 from coriander), of which two samples were sourced from Israel and eight from Cyprus. The presence of STEC was suspected in 11 out of 592 samples (25g) (1.9%; 3 basil and 8 coriander), due to the detection of stx and eae genes, of which one sample originated from Belgium, four from Israel and six from Cyprus. No STEC was isolated by culture techniques, but in three samples a serotype (O26, O103 or O111) with its most likely associated eae-variant (β or θ) was detected by PCR. Generic E. coli was enumerated in 108 out of 592 samples, whereby 55, 32 and 13 samples respectively between 10-100, 100-1000 and 1000-10,000cfu/g and 8 samples exceeding 10,000cfu/g. Coliforms were enumerated in all herb samples at variable levels ranging from 1.6 to 7.5logcfu/g. Further statistics indicate that the E. coli class (categorized by level) was significantly correlated with the presence of Salmonella (p<0.001) or STEC (p=0.019), while coliform counts were significant correlated with Salmonella (p<0.001), but not with STEC (p=0.405). Generic E. coli class is a better indicator for the presence of enteric pathogens than coliforms on fresh herbs, but the relationship between E. coli and Salmonella or STEC was not strong enough to provide a threshold value for E. coli to assure food safety (i.e. no pathogens present). Results indicate that fresh leafy herbs like basil and coriander sourced from different cultivation regions, may contain enteric pathogens and potentially pose a risk for human health. Copyright © 2015 Elsevier B.V. All rights reserved.
Kutto, E K; Ngigi, M W; Karanja, N; Kange'the, E; Bebora, L C; Lagerkvist, C J; Mbuthia, P G; Njagi, L W; Okello, J J
2011-02-01
To assess the microbiological safety of kale (Brassica oleracea Acephala) produced from farms and those sold at the markets with special focus on coliforms, E.coli and Salmonella. A cross sectional study. Peri-Urban farms (in Athi River, Ngong and Wangige), wet markets (in Kawangware, Kangemi and Githurai), supermarkets and high-end specialty store both within Nairobi city. Mean coliform count on vegetables from farms were 2.6 x 10(5) +/- 5.0 x 10(5) cfu/g while those from the wet markets were 4.6 x 10(6) +/- 9.1 x 10(6) cfu/g, supermarkets, 2.6 x 10(6) +/- 2.7 x 10(6) and high-end specialty store 4.7 x 10(5) +/- 8.9 x 10 (5). Coliform numbers obtained on kales from the wet markets and supermarkets were significantly higher (p < 0.05) compared to those from farms, while kale samples purchased from high-end specialty store had similar levels of coliform loads as those from the farms. E. coli prevalence in the wet markets, supermarkets and high-end specialty store were: 40, 20 and 20%, respectively. Salmonella was detected on 4.5 and 6.3% of samples collected from the farms in Wangige and wet market in Kawangware, respectively. Fecal coliforms in water used on farms (for irrigation) and in the markets (for washing the vegetables) exceeded levels recommended by World Health Organization (WHO) of 10(3) organisms per 100 milliliter while Salmonella was detected in 12.5% of washing water samples collected from Kangemi market. Poor cultivation practices and poor handling of vegetables along the supply chain could increase the risk of pathogen contamination thus puting the health of the public at risk, therefore good agricultural and handling practices should be observed.
Design, construction and performance of a horizontal subsurface flow wetland system in Australia.
Bolton, Lise M W; Bolton, Keith G E
2013-01-01
Malabugilmah is a remote Aboriginal community located in Clarence Valley, Northern NSW, Australia. In 2006, seven horizontal subsurface flow wetland clusters consisting of 3 m × 2 m wetland cells in series were designed and constructed to treat septic tank effluent to a secondary level (Total Suspended Solids (TSS) < 30 mg/L and Biochemical Oxygen Demand (BOD5) <20 mg/L) and achieve >50% Total Nitrogen (TN) reduction, no net Total Phosphorus (TP) export and ≥99.9% Faecal Coliform (FC) reduction. The wetland cell configuration allowed the wetlands to be located on steeper terrain, enabling effluent to be treated to a secondary level without the use of pumps. In addition to the water quality targets, the wetlands were designed and constructed to satisfy environmental, economic and social needs of the community. The wetland systems were planted with a local Australian wetland tree species which has become well established. Two wetland clusters have been monitored over the last 4 years. The wetlands have demonstrated to be robust over time, providing a high level of secondary treatment over an extended period.
Blackwell, Karen Dyer; Oliver, James D
2008-04-01
While numerous studies have characterized the distribution and/or ecology of various pathogenic Vibrio spp., here we have simultaneously examined several estuarine sites for Vibrio vulnificus, V. cholerae, and V. parahaemolyticus. For a one year period, waters and sediment were monitored for the presence of these three pathogens at six different sites on the east coast of North Carolina in the United States. All three pathogens, identified using colony hybridization and PCR methods, occurred in these estuarine environments, although V. cholerae occurred only infrequently and at very low levels. Seventeen chemical, physical, and biological parameters were investigated, including salinity, water temperature, turbidity, dissolved oxygen, levels of various inorganic nutrients and dissolved organic carbon, as well as total vibrios, total coliforms, and E. coli. We found each of the Vibrio spp. in water and sediment to correlate to several of these environmental measurements, with water temperature and total Vibrio levels correlating highly (P<0.0001) with occurrence of the three pathogens. Thus, these two parameters may represent simple assays for characterizing the potential public health hazard of estuarine waters.
Elimination of coliforms and Salmonella spp. in sheep meat by gamma irradiation treatment
Henriques, Luciana Salles Vasconcelos; da Costa Henry, Fábio; Barbosa, João Batista; Ladeira, Silvania Alves; de Faria Pereira, Silvia Menezes; da Silva Antonio, Isabela Maria; Teixeira, Gina Nunes; Martins, Meire Lelis Leal; de Carvalho Vital, Helio; dos Prazeres Rodrigues, Dália; dos Reis, Eliane Moura Falavina
2013-01-01
This study aimed at evaluating the bacteriological effects of the treatment of sheep meat contaminated with total coliforms, coliforms at 45 °C and Salmonella spp. by using irradiation at doses of 3 kGy and 5 kGy. Thirty sheep meat samples were collected from animals located in Rio de Janeiro State, Brazil, and then grouped in three lots including 10 samples: non-irradiated (control); irradiated with 3 kGy; and irradiated with 5 kGy. Exposure to gamma radiation in a 137Cs source-driven irradiating facility was perfomed at the Nuclear Defense Section of the Brazilian Army Technological Center (CTEx) in Rio de Janeiro. The samples were kept under freezing temperature (−18 °C) until the analyses, which occurred in two and four months after irradiation. The results were interpreted by comparison with the standards of the current legislation and demonstrated that non-irradiated samples were outside the parameters established by law for all groups of bacteria studied. Gamma irradiation was effective in inactivating those microorganisms at both doses tested and the optimal dose was achieved at 3 kGy. The results have shown not only the need for sanitary conditions improvements in slaughter and processing of sheep meat but also the irradiation effectiveness to eliminate coliform bacteria and Salmonella spp. PMID:24688504
Biodiesel production from indigenous microalgae grown in wastewater.
Komolafe, Oladapo; Velasquez Orta, Sharon B; Monje-Ramirez, Ignacio; Yáñez Noguez, Isaura; Harvey, Adam P; Orta Ledesma, María T
2014-02-01
This paper describes a process for producing biodiesel sustainably from microalgae grown in wastewater, whilst significantly reducing the wastewater's nutrients and total coliform. Furthermore, ozone-flotation harvesting of the resultant biomass was investigated, shown to be viable, and resulted in FAMEs of greater oxidation stability. Desmodesmus sp. and two mixed cultures were successfully grown on wastewater. Desmodesmus sp. grew rapidly, to a higher maximum biomass concentration of 0.58 g/L. A native mixed culture dominated by Oscillatoria and Arthrospira, reached 0.45 g/L and exhibited the highest lipid and FAME yield. The FAME obtained from ozone-flotation exhibited the greatest oxidative stability, as the degree of saturation was high. In principle ozone could therefore be used as a combined method of harvesting and reducing FAME unsaturation. During microalgae treatment, the total nitrogen in wastewater was reduced by 55.4-83.9%. More importantly, total coliform removal was as high as 99.8%. Copyright © 2013 Elsevier Ltd. All rights reserved.
Use of natural compounds to improve the microbial stability of Amaranth-based homemade fresh pasta.
Del Nobile, M A; Di Benedetto, N; Suriano, N; Conte, A; Lamacchia, C; Corbo, M R; Sinigaglia, M
2009-04-01
A study on the use of natural antimicrobial compounds to improve the microbiological stability of refrigerated amaranth-based homemade fresh pasta is presented in this work. In particular, the antimicrobial activity of thymol, lemon extract, chitosan and grapefruit seed extract (GFSE) has been tested against mesophilic and psychrotrophic bacteria, total coliforms, Staphylococcus spp., yeasts and moulds. A sensory analysis on both fresh and cooked pasta was also run. Results suggest that chitosan and GFSE strongly increase the microbial acceptability limit of the investigated spoilage microorganisms, being the former the most effective. Thymol efficiently reduces the growth of mesophilic bacteria, psychrotrophic bacteria and Staphylococcus spp., whereas it does not affect, substantially, the growth cycle of total coliforms. Lemon extract is the less effective in preventing microbial growth. In fact, it is able to delay only total mesophilic and psychrotrophic bacterial evolution. From a sensorial point of view no significant differences were recorded between the control samples and all the types of loaded amaranth-based pasta.
Schmidt, Radomir; Klemme, David A; Scow, Kate; Hristova, Krassimira
2012-03-30
A pilot-scale sand-based fluidized bed bioreactor (FBBR) was utilized to treat both methyl tert-butyl ether (MTBE) and tert-butyl alcohol (TBA) from a contaminated aquifer. To evaluate the potential for re-use of the treated water, we tested for a panel of water quality indicator microorganisms and potential waterborne pathogens including total coliforms, Escherichia coli, Salmonella and Shigella spp., Campylobacter jejuni, Aeromonas hydrophila, Legionella pneumophila, Vibrio cholerae, Yersinia enterocolytica and Mycobacterium avium in both influent and treated waters from the bioreactor. Total bacteria decreased during FBBR treatment. E. coli, Salmonella and Shigella spp., C. jejuni, V. cholerae, Y. enterocolytica and M. avium were not detected in aquifer water or bioreactor treated water samples. For those pathogens detected, including total coliforms, L. pneumophila and A. hydrophila, numbers were usually lower in treated water than influent samples, suggesting removal during treatment. The detection of particular bacterial species reflected their presence or absence in the influent waters. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Frimpong, G. K.; Kottoh, I. D.; Ofosu, D. O.; Larbi, D.
2015-05-01
The effect of ionizing radiation on the microbiological quality on minimally processed carrot and lettuce was studied. The aim was to investigate the effect of irradiation as a sanitizing agent on the bacteriological quality of some raw eaten salad vegetables obtained from retailers in Accra, Ghana. Minimally processed carrot and lettuce were analysed for total viable count, total coliform count and pathogenic organisms. The samples collected were treated and analysed for a 15 day period. The total viable count for carrot ranged from 1.49 to 14.01 log10 cfu/10 g while that of lettuce was 0.70 to 8.5 7 log10 cfu/10 g. It was also observed that total coliform count for carrot was 1.46-7.53 log10 cfu/10 g and 0.14-7.35 log10 cfu/10 g for lettuce. The predominant pathogenic organisms identified were Bacillus cereus, Cronobacter sakazakii, Staphylococcus aureus, and Klebsiella spp. It was concluded that 2 kGy was most effective for medium dose treatment of minimally processed carrot and lettuce.
Rai, Prabhat Kumar; Tripathi, B D
2007-10-01
A total of 144 samples of water used for irrigation were collected from Dinapur, DLW sewage treatment plant and river water of Ganga at Rajghat and 258 irrigated vegetable samples were collected from nearby agricultural fields in the close vicinity of three treatment plants and examined using standard procedures for coliform and viable counts and the presence of Escherichia coli, Salmonella, Clostridium and Vibrio during the winter and rainy seasons. Irrigation water from Rajghat drain had significantly higher coliform counts by location and season than the water from the Dinapur and DLW. Although all the vegetables had coliform counts higher than the recommended standard (range 3.40 - 6.38 log10 cfuml(-1)), spinach and cabbage had significantly higher (p < 0.05) counts compared to other vegetables during the dry season. Salmonella was significantly more likely to be detected during the rainy season than during the dry season. Contaminated vegetable intake may pose a serious threat to human health.
Microbiological survey of five poultry processing plants in the UK.
Mead, G C; Hudson, W R; Hinton, M H
1993-07-01
1. Neck skin samples were taken from chickens and turkeys at all the main stages of processing to monitor changes in total viable count (TVC) and counts of coliforms and pseudomonads. 2. Processing reduced TVC by up to 100-fold. Geometric mean counts after packaging were log10 4.4 to 5.3 CFU/g whilst corresponding counts of coliforms were 2.7 to 3.8 CFU/g. 3. Increases in mean TVC or coliforms as a result of either defeathering or evisceration did not exceed 0.6 log. 4. Pseudomonads represented only a minor fraction of the initial microflora of the bird and were often reduced by scalding to a figure which could not be detected by direct plating of samples; however, subsequent contamination resulted in means between log10 2.9 and 4.0 CFU/g for packaged carcases. 5. Although Staphylococcus aureus was readily isolated from defeathering equipment, mean counts from defeathered carcases were always below log10 3.0 CFU/g.
Potential tracers for tracking septic tank effluent discharges in watercourses.
Richards, Samia; Withers, Paul J A; Paterson, Eric; McRoberts, Colin W; Stutter, Marc
2017-09-01
Septic tank effluent (STE) contributes to catchment nutrient and pollutant loads. To assess the role of STE discharges in impairment of surface water, it is essential to identify the sources of pollution by tracing contaminants in watercourses. We examined tracers that were present in STE to establish their potential for identifying STE contamination in two stream systems (low and high dilution levels) against the background of upstream sources. The studied tracers were microbial, organic matter fluorescence, caffeine, artificial sweeteners and effluent chemical concentrations. The results revealed that tracer concentration ratios Cl/EC, Cl/NH 4 -N, Cl/TN, Cl/TSS, Cl/turbidity, Cl/total coliforms, Cl/sucralose, Cl/saccharin and Cl/Zn had potential as tracers in the stream with low dilution level (P < 0.05). Fluorescence spectroscopy could detect STE inputs through the presence of the tryptophan-like peak, but was limited to water courses with low level of dilution and was positively correlated with stream Escherichia coli (E. coli) and soluble reactive phosphorus (SRP). The results also suggested that caffeine and artificial sweeteners can be suitable tracers for effluent discharge in streams with low and high level of dilution. Caffeine and saccharin were positively correlated with faecal coliforms, E. coli, total P and SRP, indicating their potential to trace discharge of a faecal origin and to be a marker for effluent P. Caffeine and SRP had similar attenuation behaviour in the receiving stream waters suggesting caffeine's potential role as a surrogate indicator for the behaviour of P downstream of effluent inputs. Taken together, results suggest that a single tracer alone was not sufficient to evaluate STE contamination of watercourses, but rather a combination of multiple chemical and physical tracing approaches should be employed. A multiple tracing approach would help to identify individual and cumulative STE inputs that pose risks to stream waters in order to prioritise and target effective mitigation measures. Copyright © 2017 Elsevier Ltd. All rights reserved.
Total Coliform Rule Compliance Help for Primacy Agencies
This document provides guidance to states, tribes and the EPA Regions exercising primary enforcement responsibility under the Safe Drinking Water Act (SDWA). It contains EPA’s current policy recommendations for complying with the RTCR.
2004-02-19
County 142.9 17 421 60 2253 3800 PO-POBLVD Port Orchard Blvd Port Orchard 314.6 17 291 20 3119 14000 PSNS015 Naval Station McDonalds PSNS 109.5 12 1629...Stream Mouth south of Bea 47.55253 -122.60112 1 1 BL- KFC (BJ01) ECOLOGY BLACKJACK CREEK ( KFC ) Behind KFC 47.54172 -122.62777 1 1 OC KPUD OLNEY CREEK...Com/Res/Rec is a 36” diameter smooth bore concrete storm water outfall pipe located adjacent to McDonalds , near the south side of the drive-through
Effects of septic tank effluent on ground-water quality, Dade County, Florida: an interim report
Pitt, William A.
1974-01-01
Except at one site, no fecal coliforms were found below the 10-foot depth. Total coliforms exceeded a count of one colony per ml at the 60- foot depth at two sites. At one site a fecal streptococci count of 53 colonies per ml was found at the 60-foot depth and at another a count of seven colonies was found at the 40-foot depth. The three types of bacteria occur in higher concentration in the northern areas of the county than in the south. Bacteria concentrations were also higher where the septic tanks were more concentrated.
Mogna, Luca; Del Piano, Mario; Mogna, Giovanni
2014-01-01
The total number of bacteria present in the gut microbiota of a newborn is consistently lower than the average found in adults, with the extent of this difference being directly related to body weight and age. It could be assumed that a lower number of viable probiotic cells is necessary to achieve significant gut colonization in infants and children. This study assessed the capability of Bifidobacterium breve B632 (DSM 24706) and Bifidobacterium breve BR03 (DSM 16604), 2 strains able to significantly inhibit some gram-negative bacteria in vitro, to integrate into the intestinal microbiota of children. Ten healthy children aged an average of 5.7±2.6 were given an oily suspension containing B. breve B632 and B. breve BR03 for 21 consecutive days. The daily dose was 100 million live cells of each strain. Fecal specimens were collected and analyzed at the beginning (d0) and at the end of the study (d21). Total fecal bifidobacteria and coliforms have been quantified by microbiological plate counts. A significant increase in total fecal bifidobacteria (from 8.99 to 9.47 log10 CFU/g, P=0.042) and a parallel decrease in total coliforms (from 8.60 to 7.93 log10 CFU/g, P=0.048) was recorded after 21 days of supplementation. An oily suspension has proved an effective way of providing probiotics to children. A lower viable cells concentration was sufficient to mediate this effect in the light of the fact that the intestinal microbiota of children harbors a considerably smaller amount of total bacteria compared with adults. In addition to gut colonization in healthy children, B. breve B632 and B. breve BR03 were able to decrease total fecal coliforms, therefore supporting their potential specific use in colicky infants.
Wastewater renovation using constructed soil filter (CSF): a novel approach.
Nemade, P D; Kadam, A M; Shankar, H S
2009-10-30
Constructed soil filter (CSF) also known as Soil Biotechnology (SBT) is a process for water renovation which makes use of formulated media with culture of soil macro- and microorganisms. CSF combines sedimentation, infiltration and biodegradation processes to remove oxidizable organics and inorganics of wastewater in a single facility. Operating experience shows hydraulic loading in the range of 0.05-0.25 m(3)/m(2) h and organic loading up to 200-680 g/m(2) d. The results show increase in dissolved oxygen levels, COD removal (from 352 mg/l to 20 mg/l); BOD removal (from 211 mg/l to 7.0 mg/l); suspended solids removal (from 293 mg/l to 16 mg/l); turbidity reduction (from 145 NTU to 5.3 NTU); iron (from 5 mg/l to 0.3 mg/l); arsenic (from 500 microg/l to 10 microg/l); total coliform and fecal coliform removal (from 145 x 10(5) to 55 CFU/100 mL and 150 x 10(8) to 110 CFU/100 mL respectively), with desired pathogen levels as per WHO standards, i.e. < or =10(3) CFU/100 mL. CSF reveals advantages such as low HRT (0.5-2.0 h), low energy requirement (0.04 kWh/m(3)), no pre-treatment, high dissolved oxygen levels in the effluent, no biosludge production, no mechanical aeration and no odor, fish compatible water quality and evergreen ambience.
Kim, Chyer; Stein, Roslyn A; Pao, Steven
2015-11-01
This study was conducted to evaluate the microbial quality of lamb and goat meat sold through local (Virginia) and Internet (U. S.) retail markets. A total of 134 frozen meat products consisting of locally purchased lamb ground (LLG) and lamb chops and Internet-procured lamb ground, goat ground, lamb chops (ILC), goat chops (IGC), lamb stew, and goat stew were tested. Significantly higher levels of aerobic mesophiles, psychrotrophs, and coliforms were found in the meat locally acquired than in the meat procured from the Internet. Similar average prevalence (27%) of Escherichia coli was observed regardless of market source. Ground meat had significantly high levels and prevalence of mesophiles, psychrotrophs, coliforms, and Listeria spp. One sample of LLG contained Campylobacter, and one sample of IGC contained Salmonella. Listeria spp. were present in 23 to 40% and 17 to 80% of samples from local and Internet markets, respectively. Pulsed-field gel electrophoresis (PFGE) of isolated E. coli strains revealed brand specificity and genomic diversity. No isolate from different brands and market sources had matching PFGE profiles. The average price of Internet meat ($23.4/kg) was about 1.2 times higher than the price of local meat, except for ILC, whose price was 2.7 times higher. This study revealed differences in microbial quality of lamb and goat meat based on market source; thus, meat products should be handled carefully regardless of market source because of the presence of high microbial levels and the high prevalence of pathogens.
75 FR 70918 - Meeting of the National Drinking Water Advisory Council-Notice of Public Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-19
... evaluating the report and determining what recommendations the Council will transmit to the Administrator..., the Underground Injection Control (UIC) Program, and revisions to the 1989 Total Coliform Rule (RTCR...
Ecology of Vibrio vulnificus in estuarine waters of eastern North Carolina.
Pfeffer, Courtney S; Hite, M Frances; Oliver, James D
2003-06-01
While several studies on the ecology of Vibrio vulnificus in Gulf Coast environments have been reported, there is little information on the distribution of this pathogen in East Coast waters. Thus, we conducted a multiyear study on the ecology of V. vulnificus in estuarine waters of the eastern United States, employing extensive multiple regression analyses to reveal the major environmental factors controlling the presence of this pathogen, and of Vibrio spp., in these environments. Monthly field samplings were conducted between July 2000 and April 2002 at six different estuarine sites along the eastern coast of North Carolina. At each site, water samples were taken and nine physicochemical parameters were measured. V. vulnificus isolates, along with estuarine bacteria, Vibrio spp., Escherichia coli organisms, and total coliforms, were enumerated in samples from each site by using selective media. During the last 6 months of the study, sediment samples were also analyzed for the presence of vibrios, including V. vulnificus. Isolates were confirmed as V. vulnificus by using hemolysin gene PCR or colony hybridization. V. vulnificus was isolated only when water temperatures were between 15 and 27 degrees C, and its presence correlated with water temperature and dissolved oxygen and vibrio levels. Levels of V. vulnificus in sediments were low, and no evidence for an overwintering in this environment was found. Multiple regression analysis indicated that vibrio levels were controlled primarily by temperature, turbidity, and levels of dissolved oxygen, estuarine bacteria, and coliforms. Water temperature accounted for most of the variability in the concentrations of both V. vulnificus (47%) and Vibrio spp. (48%).
Barrera-Díaz, Carlos E; Frontana-Uribe, Bernardo A; Roa-Morales, Gabriela; Bilyeu, Bryan W
2015-01-01
The objective of this study was to evaluate the effect of copper electrocoagulation and hydrogen peroxide on COD, color, turbidity, and bacterial activity in a mixed industry wastewater. The integrated system of copper electrocoagulation and hydrogen peroxide is effective at reducing the organic and bacterial content of industrial wastewater. The copper electrocoagulation alone reduces COD by 56% in 30 min at pH 2.8, but the combined system reduces COD by 78%, biochemical oxygen demand (BOD5) by 81%, and color by 97% under the same conditions. Colloidal particles are flocculated effectively, as shown by the reduction of zeta potential and the 84% reduction in turbidity and 99% reduction in total solids. Additionally, the total coliforms, fecal coliforms, and bacteria are all reduced by 99%. The integrated system is effective and practical for the reduction of both organic and bacterial content in industrial wastewater.
Pollutant loads and water quality in streams of heavily populated and industrialised towns
NASA Astrophysics Data System (ADS)
Ntengwe, F. W.
The availability of portable water is often taken for granted and water allowed to get polluted. Industries, settlements, farms, markets, leaking sewer lines, poor hygiene practices are all potential sources of pollution. Each pollutant has its own effect on water and the environment. A study was conducted in Kitwe Stream in order to establish whether engineering and other human activities affect water quality. Samples were collected at ten points, the first point being at the source while the tenth point was at the confluence with the Kafue River. The samples were analysed for physical, chemical and biological parameters. The results revealed high levels of concentration and loads of total suspended solids (TSS). The points with high TSS values were P4 (118 mg/l) and P6 (140 mg/l) representing daily loads of 7.74 and 8.71 tonnes, respectively. The highest values of coliform were found at points P9 (2099), P10 (2558) followed by P4 (1149), P5 (1256) and P6 (1370). High values of nitrites were found at points P4 (34 mg/l), P5 (32 mg/l), P6 (21 mg/l) and P10 (12.4 mg/l). Chlorides were also found to be high at points P4, P5 and P6 with values of 70 mg/l, 80 mg/l and 87 mg/l, respectively. These parameters exceeded the maximum contaminant level (MCL) of 100 mg/l for TSS, 1 mg/l for nitrites, 500/100 ml for coliform in Zambia. The conductivity and coliform were also found to be high (>500 μS/cm, >500). The benthic study revealed a normal diversity of invertebrates but chironomidae was found to be on average 60% of total species counted. The fish activity was high upstream and low downstream at the mouth of the stream where it joins the Kafue River. There was no fish activity at the middle points. The planktons (phytoplankton and zooplankton) count revealed a high count (15-30 per ml) in places where there was high fish activity and a low count (1-5 per ml) where there was no activity. The stream water quality was therefore affected by the human activities.
Influence of preservation methods on the quality of colostrum sourced from New Zealand dairy farms.
Denholm, K S; Hunnam, J C; Cuttance, E L; McDougall, S
2017-09-01
To assess the effect of two temperatures (ambient temperature and 4°C), three preservation methods (no preservative, yoghurt and potassium sorbate), and two periods of storage (3 and 7 days) on Brix and total bacterial and coliform counts of colostrum collected from New Zealand dairy farms. One litre of colostrum destined to be fed to newborn calves was collected from 55 New Zealand dairy farms in the spring of 2015. Six aliquots of 150 mL were obtained from each colostrum sample, with two aliquots left untreated, two treated with potassium sorbate and two with yoghurt, and one of each pair of aliquots stored at ambient temperature and the other at 4°C. All samples were tested for Brix, total bacterial counts and coliform counts before treatment (Day 0), and after 3 and 7 days of storage. The effect of preservation method and storage temperature on the change in Brix, bacterial and coliform counts after 3 or 7 days of storage was analysed using multivariable random effects models. For all outcome variables there was a temperature by preservation interaction. For aliquots preserved with potassium sorbate, changes in Brix and bacterial counts did not differ between aliquots stored at ambient temperature or 4°C, but for aliquots preserved with yoghurt or no preservative the decrease in Brix and increase in bacterial counts was greater for aliquots stored at ambient temperature than 4°C (p<0.001). For aliquots preserved with potassium sorbate, coliform counts decreased at both temperatures, but for aliquots preserved with yoghurt or no preservative coliform counts increased for aliquots stored at 4°C, but generally decreased at ambient temperatures (p<0.001). There was also an interaction between duration of storage and temperature for bacterial counts (p<0.001). The difference in the increase in bacterial counts between aliquots stored at 4°C and ambient temperature after 3 days was greater than between aliquots stored at 4°C and ambient temperature after 7 days. Use of potassium sorbate to preserve colostrum for 3 or 7 days resulted in little or no reduction in Brix and a lower increase in total bacterial counts than colostrum stored without preservative or with yoghurt added. Colostrum quality was not affected by storage temperature for samples preserved with potassium sorbate, but storage at 4°C resulted in better quality colostrum than storage at ambient temperatures for colostrum with no preservative or yoghurt added.
The current situation and environmental conditions of green mussel farming in the gulf of Thailand
NASA Astrophysics Data System (ADS)
Keawtawee, T.; Songsangjinda, P.; Sangnoi, Y.; Uppabullung, A.
2018-04-01
This study investigated the current situation and environmental conditions of green mussel Perna viridis farming in Surat Thani, Phetchaburi and Samut Prakan provinces where were located in the gulf of Thailand. Samples were collected during April, August and November in 2014. Based on the results of this study, there were three major types of mussel culture patterns in Thailand: bouchot culture, longline culture (rope culture), and raft culture. Mussel farmers encountered problems on decreasing of larvae mussel in the water column, water quality degradation, high production cost and farmer’s lack of negotiation power to control the price. The water quality of the mussel farms, such as dissolved oxygen (DO), pH, salinity, electrical conductivity (EC), fecal coliforms bacteria and the total coliforms bacteria met the standard for aquaculture. However, the nutrient, such as ammonium (NH4-N), nitri-nitrogen (NO2-N), nitrate-nitrogen (NO3-N) and soluble reactive phosphorus (PO4-P) were higher than the value of marine aquaculture standard. The results of the contamination of Salmonella spp. bacteria were not found in the mussel’s tissue, however Escherichia coli was found at very low level.
Conclusions on measurement uncertainty in microbiology.
Forster, Lynne I
2009-01-01
Since its first issue in 1999, testing laboratories wishing to comply with all the requirements of ISO/IEC 17025 have been collecting data for estimating uncertainty of measurement for quantitative determinations. In the microbiological field of testing, some debate has arisen as to whether uncertainty needs to be estimated for each method performed in the laboratory for each type of sample matrix tested. Queries also arise concerning the estimation of uncertainty when plate/membrane filter colony counts are below recommended method counting range limits. A selection of water samples (with low to high contamination) was tested in replicate with the associated uncertainty of measurement being estimated from the analytical results obtained. The analyses performed on the water samples included total coliforms, fecal coliforms, fecal streptococci by membrane filtration, and heterotrophic plate counts by the pour plate technique. For those samples where plate/membrane filter colony counts were > or =20, uncertainty estimates at a 95% confidence level were very similar for the methods, being estimated as 0.13, 0.14, 0.14, and 0.12, respectively. For those samples where plate/membrane filter colony counts were <20, estimated uncertainty values for each sample showed close agreement with published confidence limits established using a Poisson distribution approach.
Assessment of groundwater quality in a typical rural settlement in southwest Nigeria.
Adekunle, I M; Adetunji, M T; Gbadebo, A M; Banjoko, O P
2007-12-01
In most rural settlements in Nigeria, access to clean and potable water is a great challenge, resulting in water borne diseases. The aim of this study was to assess the levels of some physical, chemical, biochemical and microbial water quality parameters in twelve hand - dug wells in a typical rural area (Igbora) of southwest region of the country. Seasonal variations and proximity to pollution sources (municipal waste dumps and defecation sites) were also examined. Parameters were determined using standard procedures. All parameters were detected up to 200 m from pollution source and most of them increased in concentration during the rainy season over the dry periods, pointing to infiltrations from storm water. Coliform population, Pb, NO3- and Cd in most cases, exceeded the World Health Organization recommended thresholds for potable water. Effect of distance from pollution sources was more pronounced on fecal and total coliform counts, which decreased with increasing distance from waste dumps. The qualities of the well water samples were therefore not suitable for human consumption without adequate treatment. Regular monitoring of groundwater quality, abolishment of unhealthy waste disposal practices and introduction of modern techniques are recommended.
Physicochemical and bacteriological characterization of raw sewage from the Meknes region Morocco
NASA Astrophysics Data System (ADS)
Hassan, Ouallal; Hamzaoui Najia, El; Mohammed, Sbiti; Mohammed, Machkor; Lahcen, Messaoudi; Mohamed, Azrour
2018-05-01
The region of Meknes suffers from a significant delay in the water sector, including sewage treatment. The Urban waste water in the region originates from various activities; households, industry, agriculture and hospital. These waters are released in to nature without any treatment, which constitutes a serious risk for the environment. The objective of this research is to characterize the physicochemical and bacteriological pollution of the three sewage collectors of the Meknes region (Aïn Choubbik, Oued Ouislane and Aïn Taoujdate). Indeed, the pollution parameters; biological and chemical oxygen demand are abnormally high, which indicates clearly that waste waters is rich of reducing or oxidizing organic materials. Ammonium, nitrogen, phosphorus and heavy metals concentrations exceed the limit values. So these waters are classified as bad or very bad quality. On the one hand, the presence of a large bacterial load indicates fecal contamination. The total coliform, fecal coliform and fecal streptococci levels are high exceeding exceed the values specified the WHO guidelines and the Moroccan standards. This situation is likely to cause serious and irreparable damage to the environment groundwater. To counter this, make the necessary investment in sewage treatment and other remedial measures is key to preventing pollution and its spread.
Ekwanzala, Mutshiene Deogratias; Abia, Akebe Luther King; Ubomba-Jaswa, Eunice; Keshri, Jitendra; Momba, Ndombo Benteke Maggy
2017-12-01
To date, the microbiological quality of river sediments and its impact on water resources are not included in the water quality monitoring assessment. Therefore, the aim of this study was to establish genetic relatedness between faecal coliforms and enterococci isolated from the river water and riverbed sediments of Apies River to better understand the genetic similarity of microorganisms between the sediment and water phases. Indicator bacteria were subjected to a molecular study, which consisted of PCR amplification and sequence analysis of the 16S rRNA and 23S rRNA gene using specific primers for faecal coliforms and enterococci, respectively. Results revealed that the Apies River had high faecal pollution levels with enterococci showing low to moderate correlation coefficient (r 2 values ranged from 0.2605 to 0.7499) compared to the faecal coliforms which showed zero to low correlation (r 2 values ranged from 0.0027 to 0.1407) indicating that enterococci may be better indicator than faecal coliforms for detecting faecal contamination in riverbed sediments. The phylogenetic tree of faecal coliforms revealed a 98% homology among their nucleotide sequences confirming the close genetic relatedness between river water and riverbed sediment isolates. The phylogenetic tree of the enterococci showed that Enterococcus faecalis and Enterococcus faecium are the predominant species found in both river water and riverbed sediments with bootstrap values of ≥99%. A high degree of genetic relatedness between sediment and water isolates indicated a possible common ancestry and transmission pathway. We recommend the microbial monitoring of riverbed sediments as it harbours more diverse microbial community and once resuspended may cause health and environmental problems.
2013-01-01
The aim of this study was to investigate the performance of a two-stage fluidized bed reactor (FBR) system for the post-treatment of secondary wastewater treatment plant effluents (Shahrak Gharb, Tehran, Iran). The proposed treatment scheme was evaluated using pilot-scale reactors (106-L of capacity) filled with PVC as the fluidized bed (first stage) and gravel for the filtration purpose (second stage). Aluminum sulfate (30 mg/L) and chlorine (1 mg/L) were used for the coagulation and disinfection of the effluent, respectively. To monitor the performance of the FBR system, variation of several parameters (biochemical oxygen demand (BOD5), chemical oxygen demand (COD), turbidity, total phosphorous, total coliform and fecal coliform) were monitored in the effluent wastewater samples. The results showed that the proposed system could effectively reduce BOD5 and COD below 1.95 and 4.06 mg/L, respectively. Turbidity of the effluent could be achieved below 0.75 NTU, which was lower than those reported for the disinfection purpose. The total phosphorus was reduced to 0.52 mg/L, which was near the present phosphorous standard for the prevention of eutrophication process. Depending on both microorganism concentration and applied surface loading rates (5–10 m/h), about 35 to 75% and 67 to 97% of coliform were removed without and with the chlorine addition, respectively. Findings of this study clearly confirmed the efficiency of the FBR system for the post-treatment of the secondary wastewater treatment plant effluents without any solid problem during the chlorination. PMID:24499570
Spatio-temporal evaluation of Yamchi Dam basin water quality using Canadian water quality index.
Farzadkia, Mahdi; Djahed, Babak; Shahsavani, Esmaeel; Poureshg, Yousef
2015-04-01
In recent years, the growth of population and increase of the industries around the tributaries of Yamchi Dam basin have led to deterioration of dam water quality. This study aimed to evaluate the quality of the Yamchi Dam basin water, which is used for drinking and irrigation consumptions using Canadian Water Quality Index (CWQI) model, and to determine the main water pollution sources of this basin. Initially, nine sampling stations were selected in the sensitive locations of the mentioned basin's tributaries, and 12 physico-chemical parameters and 2 biological parameters were measured. The CWQI for drinking consumptions was under 40 at all the stations indicating a poor water quality for drinking consumptions. On the other hand, the CWQI was 62-100 for irrigation at different stations; thus, the water had an excellent to fair quality for irrigation consumptions. Almost in all the stations, the quality of irrigation and drinking water in cold season was better. Besides, for drinking use, total coliform and fecal coliform had the highest frequency of failure, and total coliform had the maximum deviation from the specified objective. For irrigation use, total suspended solids had the highest frequency of failure and deviation from the objective in most of the stations. The pisciculture center, aquaculture center, and the Nir City wastewater discharge were determined as the main pollution sources of the Yamchi Dam basin. Therefore, to improve the water quality in this important surface water resource, urban and industrial wastewater treatment prior to disposal and more stringent environmental legislations are recommended.
Koczura, R; Krysiak, N; Taraszewska, A; Mokracka, J
2015-08-01
To characterize the integron-harbouring Gram-negative bacteria in recreational lakes, with focus on the genetic content of integrons, antimicrobial resistance profiles and virulence-associated genes. The presence and structure of integrons in coliform bacteria isolated from the water of four recreational lakes located in Poznań, Poland, was determined by PCR method. Antimicrobial resistance testing was done by disc diffusion method. Virulence-associated genes in integron-bearing Escherichia coli isolates were detected by PCR. A total of 155 integron-bearing strains of coliform bacteria were cultured. Sequence analysis showed the presence of dfrA7, aadA1, dfrA1-aadA1, dfrA17-aadA5 and dfrA12-orfF-aadA2 gene cassette arrays in class 1 integrons and dfrA1-sat2-aadA1 in class 2 integrons. Higher frequency of integron-positive bacteria and higher antimicrobial resistance ranges were noted in colder months (January and November) compared with spring and summer months. The integron-harbouring E. coli carried up to nine virulence-associated genes, with the highest frequency of kpsMT (84.6%) and traT (783%), coding for group 2 capsule and determining human serum resistance respectively. Integron-bearing multidrug resistant coliform bacteria carrying virulence genes are present in waters of recreational lakes. This study presents antimicrobial resistance and virulence-associated genes in integron-bearing coliform bacteria present in the waters of recreational lakes, which showed that multidrug resistant bacteria with virulence traits might pose a threat to public health. Moreover, the presence of genes typical for enterotoxigenic and Shiga toxin-producing E. coli is a concern. © 2015 The Society for Applied Microbiology.
Tandon, Puja; Chhibber, Sanjay; Reed, Robert H
2005-07-01
The detection and enumeration of indicator bacteria such as Escherichia coli is used to assess the extent of faecal contamination of drinking water. On the basis of this approach, the effectiveness of storing water contaminated with faecal indicator bacteria in brass or earthern vessels (mutkas) of the type used in rural India have been investigated. Suspensions of bacteria in sterile distilled water were maintained for up to 48 h in each vessel and enumerated by surface plate counts on nutrient agar (non-selective) and several selective coliform media at 37 degrees C either under standard aerobic conditions, or under conditions designed to neutralise reactive oxygen species (ROS), e.g. using an anaerobic cabinet to prepare plates of pre-reduced growth medium or by inclusion of sodium pyruvate in the growth medium, with incubation of aerobically-prepared plates in an anaerobic jar. The counts obtained for E. coli decreased on short-term storage in a brass mutka; counts for selective media were lower than for equivalent counts for non-selective medium, with ROS-neutralised conditions giving consistently higher counts than aerobic incubation. However, after 48 h, no bacteria were cultivable under any conditions. Similar results were obtained using water from environmental sources in the Panjab, and from rural households where brass and earthern mutkas are used for storage of drinking water, with enumeration on selective coliform media (presumptive total coliforms). In all cases results indicated that, while storage of water in a brass mutka can inactivate E. coli and coliforms over a 48 h period, standard aerobic plate counting using selective media may not be fully effective in enumerating sub-lethally damaged bacteria.
Beverages: bottled water. Final rule.
2009-05-29
The Food and Drug Administration (FDA) is amending its bottled water regulations to require that bottled water manufacturers test source water for total coliform, as is required for finished bottled water products, and to require, if any coliform organisms are detected in source water, that bottled water manufacturers determine whether any of the coliform organisms are Escherichia coli (E. coli), an indicator of fecal contamination. FDA also is amending its bottled water regulations to require, if any coliform organisms are detected in finished bottled water products, that bottled water manufacturers determine whether any of the coliform organisms are E. coli. FDA also is amending the adulteration provision of the bottled water standard to reflect the possibility of adulteration caused by the presence of filth. Bottled water containing E. coli will be considered adulterated, and source water containing E. coli will not be considered to be of a safe, sanitary quality and will be prohibited from use in the production of bottled water. FDA is also amending its bottled water regulations to require that, before a bottler can use source water from a source that has tested positive for E. coli, the bottler must take appropriate measures to rectify or eliminate the cause of E. coli contamination of that source, and that the bottler must keep records of such actions. Existing regulatory provisions require bottled water manufacturers to keep records of new testing required by this rule. This final rule will ensure that FDA's standards for the minimum quality of bottled water, as affected by fecal contamination, will be no less protective of the public health than those set by the Environmental Protection Agency (EPA) for public drinking water.
Mulamattathil, Suma George; Mbewe, Moses; Ateba, Collins Njie
2014-01-01
The aim of this study was to isolate and identify environmental bacteria from various raw water sources as well as the drinking water distributions system in Mafikeng, South Africa, and to determine their antibiotic resistance profiles. Water samples from five different sites (raw and drinking water) were analysed for the presence of faecal indicator bacteria as well as Aeromonas and Pseudomonas species. Faecal and total coliforms were detected in summer in the treated water samples from the Modimola dam and in the mixed water samples, with Pseudomonas spp. being the most prevalent organism. The most prevalent multiple antibiotic resistance phenotype observed was KF-AP-C-E-OT-K-TM-A. All organisms tested were resistant to erythromycin, trimethoprim, and amoxicillin. All isolates were susceptible to ciprofloxacin and faecal coliforms and Pseudomonas spp. to neomycin and streptomycin. Cluster analysis based on inhibition zone diameter data suggests that the isolates had similar chemical exposure histories. Isolates were identified using gyrB, toxA, ecfX, aerA, and hylH gene fragments and gyrB, ecfX, and hylH fragments were amplified. These results demonstrate that (i) the drinking water from Mafikeng contains various bacterial species and at times faecal and total coliforms. (ii) The various bacteria are resistant to various classes of antibiotics. PMID:25105027
Koop, G; Dik, N; Nielen, M; Lipman, L J A
2010-06-01
The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC (Fossomatic 5000, Foss, Hillerød, Denmark) and TBC (BactoScan FC 150, Foss) were measured. Staphylococcal count was correlated to SCC (r=0.40), TBC (r=0.51), and SPC (r=0.53). Coliform count was correlated to TBC (r=0.33), but not to any of the other variables. Staphylococcus aureus did not correlate to SCC. The contribution of the staphylococcal count to the SPC was 31%, whereas the coliform count comprised only 1% of the SPC. The agreement of the repeated measurements was low. This study indicates that staphylococci in goat bulk milk are related to SCC and make a significant contribution to SPC. Because of the high variation in bacterial counts, repeated sampling is necessary to draw valid conclusions from bulk milk culturing. 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Evaluation of a clay-based acidic bedding conditioner for dairy cattle bedding.
Proietto, R L; Hinckley, L S; Fox, L K; Andrew, S M
2013-02-01
This study investigated the effects of a clay-based acidic bedding conditioner on sawdust bedding pH, dry matter (DM), environmental pathogen counts, and environmental bacterial counts on teat ends of lactating dairy cows. Sixteen lactating Holstein cows were paired based on parity, days in milk, milk yield, and milk somatic cell count, and were negative for the presence of an intramammary pathogen. Within each pair, cows were randomly assigned to 1 of 2 treatments with 3-wk periods in a crossover design. Treatment groups consisted of 9 freestalls per group bedded with either untreated sawdust or sawdust with a clay-based acidic bedding conditioner, added at 3- to 4-d intervals over each 21-d period. Bedding and teat ends were aseptically sampled on d 0, 1, 2, 7, 14, and 21 for determination of environmental bacterial counts. At the same time points, bedding was sampled for DM and pH determination. The bacteria identified in the bedding material were total gram-negative bacteria, Streptococcus spp., and coliform bacteria. The bacteria identified on the teat ends were Streptococcus spp., coliform bacteria, and Klebsiella spp. Teat end score, milk somatic cell count, and intramammary pathogen presence were measured weekly. Bedding and teat cleanliness, environmental high and low temperatures, and dew point data were collected daily. The bedding conditioner reduced the pH, but not the DM, of the sawdust bedding compared with untreated sawdust. Overall environmental bacterial counts in bedding were lower for treated sawdust. Total bacterial counts in bedding and on teat ends increased with time over both periods. Compared with untreated sawdust, the treated bedding had lower counts of total gram-negative bacteria and streptococci, but not coliform counts. Teat end bacterial counts were lower for cows bedded on treated sawdust for streptococci, coliforms, and Klebsiella spp. compared with cows bedded on untreated sawdust. The clay-based acidic bedding conditioner reduced environmental pathogens in sawdust bedding and teat ends without affecting teat end integrity. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Cerna-Cortes, Jorge Francisco; Leon-Montes, Nancy; Cortes-Cueto, Ana Laura; Salas-Rangel, Laura P.; Helguera-Repetto, Addy Cecilia; Lopez-Hernandez, Daniel; Rivera-Gutierrez, Sandra; Fernandez-Rendon, Elizabeth; Gonzalez-y-Merchand, Jorge Alberto
2015-01-01
The aims of this study were to evaluate the microbiological quality and the occurrence of nontuberculous mycobacteria (NTM) in a variety of salads and sprouts from supermarkets and street vendors in Mexico City. Aerobic-mesophilic bacteria (AMB) were present in 100% of RTE-salads samples; 59% of samples were outside guidelines range (>5.17 log10 CFU per g). Although fecal coliforms (FC) were present in 32% of samples, only 8% of them exceeded the permissible limit (100 MPN/g). Regarding the 100 RTE-sprouts, all samples were also positive for AMB and total coliforms (TC) and 69% for FC. Seven NTM species were recovered from 7 salad samples; they included three M. fortuitum, two M. chelonae, one M. mucogenicum, and one M. sp. Twelve RTE-sprouts samples harbored NTM, which were identified as M. porcinum (five), M. abscessus (two), M. gordonae (two), M. mucogenicum (two), and M. avium complex (one). Most RTE-salads and RTE-sprouts had unsatisfactory microbiological quality and some harbored NTM associated with illness. No correlation between the presence of coliforms and NTM was found. Overall, these results suggest that RTE-salads and RTE-sprouts might function as vehicles for NTM transmission in humans; hence, proper handling and treatment before consumption of such products might be recommendable. PMID:25918721
Cerna-Cortes, Jorge Francisco; Leon-Montes, Nancy; Cortes-Cueto, Ana Laura; Salas-Rangel, Laura P; Helguera-Repetto, Addy Cecilia; Lopez-Hernandez, Daniel; Rivera-Gutierrez, Sandra; Fernandez-Rendon, Elizabeth; Gonzalez-y-Merchand, Jorge Alberto
2015-01-01
The aims of this study were to evaluate the microbiological quality and the occurrence of nontuberculous mycobacteria (NTM) in a variety of salads and sprouts from supermarkets and street vendors in Mexico City. Aerobic-mesophilic bacteria (AMB) were present in 100% of RTE-salads samples; 59% of samples were outside guidelines range (>5.17 log10 CFU per g). Although fecal coliforms (FC) were present in 32% of samples, only 8% of them exceeded the permissible limit (100 MPN/g). Regarding the 100 RTE-sprouts, all samples were also positive for AMB and total coliforms (TC) and 69% for FC. Seven NTM species were recovered from 7 salad samples; they included three M. fortuitum, two M. chelonae, one M. mucogenicum, and one M. sp. Twelve RTE-sprouts samples harbored NTM, which were identified as M. porcinum (five), M. abscessus (two), M. gordonae (two), M. mucogenicum (two), and M. avium complex (one). Most RTE-salads and RTE-sprouts had unsatisfactory microbiological quality and some harbored NTM associated with illness. No correlation between the presence of coliforms and NTM was found. Overall, these results suggest that RTE-salads and RTE-sprouts might function as vehicles for NTM transmission in humans; hence, proper handling and treatment before consumption of such products might be recommendable.
Ghosh, Sudipta; Mehla, Ram K; Sirohi, S K; Roy, Biswajit
2010-06-01
Thirty-six crossbred calves (Holstein cross) of 5 days of age were used to study the effect of garlic extract feeding on their performance up to the age of 2 months (pre-ruminant stage). They were randomly allotted into treatment and control groups (18 numbers in each group). Performance was evaluated by measuring average body weight (BW) gain, feed intake (dry matter (DM), total digestible nutrient (TDN) and crude protein (CP)), feed conversion efficiency (FCE; DM, TDN and CP), faecal score, faecal coliform count and feeding cost. Diets were the same for the both groups. In addition, treatment group received garlic extract supplementation at 250 mg/kg BW per day per calf. Body weight measured weekly, feed intake measured twice daily, proximate analysis of feeds and fodders analysed weekly, faecal scores monitored daily and faecal coliform count done weekly. There was significant increase in average body weight gain, feed intake and FCE and significant decrease in severity of scours as measured by faecal score and faecal coliform count in the treatment group compared to the control group (P < 0.01). Feed cost per kilogramme BW gain was significantly lower in the treatment group compared to control group (P < 0.01). The results suggest that garlic extract can be supplemented to the calves for better performance.
Wohlsen, T D
2011-08-01
The equivalence of Oxoid (CM 1046) Brilliance((TM)) E. coli/coliform selective agar to mFC agar, as used in the Australian/New Zealand Standard Method to detect thermotolerant coliforms and Escherichia coli in water samples, was assessed. A total of 244 water samples were analysed in parallel over a 5-month period. Sewage effluent samples (n = 131, sites = 43), freshwater (n = 62, sites = 18) and marine/brackish water samples (n = 51, sites = 23) were analysed. The Wilcoxon matched-pairs signed-ranks test showed a varying degree of statistical difference between the two methods. All matrices had a higher recovery in the trial method. Enterococci faecalis, Aeromonas spp. and Vibrio spp. did not grow on the CM1046 agar, and Pseudomonas aeruginosa and Enterobacter aerogenes were inhibited. The use of CM 1046 for the detection and enumeration of E. coli and thermotolerant coliforms in water samples is a suitable alternative to the AS/NZS Standard Method. The use of CM1046 agar was less labour intensive and time consuming, as no secondary confirmation steps were required. Confirmed results could be reported within 24 h of sample analysis, as compared to 48 h with the reference method. Public health concerns can be addressed in a more efficient manner. © 2011 Unitywater. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.
Quality and safety attributes of afghan raisins before and after processing
McCoy, Stacy; Chang, Jun Won; McNamara, Kevin T; Oliver, Haley F; Deering, Amanda J
2015-01-01
Raisins are an important export commodity for Afghanistan; however, Afghan packers are unable to export to markets seeking high-quality products due to limited knowledge regarding their quality and safety. To evaluate this, Afghan raisin samples from pre-, semi-, and postprocessed raisins were obtained from a raisin packer in Kabul, Afghanistan. The raisins were analyzed and compared to U.S. standards for processed raisins. The samples tested did not meet U.S. industry standards for embedded sand and pieces of stem, total soluble solids, and titratable acidity. The Afghan raisins did meet or exceed U.S. Grade A standard for the number of cap-stems, percent damaged, crystallization levels, moisture content, and color. Following processing, the number of total aerobic bacteria, yeasts, molds, and total coliforms were within the acceptable limits. Although quality issues are present in the Afghan raisins, the process used to clean the raisins is suitable to maintain food safety standards. PMID:25650241
Use of hot water for beef carcass decontamination.
Castillo, A; Lucia, L M; Goodson, K J; Savell, J W; Acuff, G R
1998-01-01
Hot water treatment of beef carcass surfaces for reduction of Escherichia coli O157:H7, Salmonella typhimurium, and various indicator organisms was studied using a model carcass spray cabinet. Paired hot carcass surface regions with different external fat characteristics (inside round, outside round, brisket, flank, and clod) were removed from carcasses immediately after the slaughter and dressing process. All cuts were inoculated with bovine feces containing 10(6)/g each of rifampicin-resistant E. coli O157:H7 and S. typhimurium, or with uninoculated bovine feces. Surfaces then were exposed to a carcass water wash or a water wash followed by hot water spray (95 degrees C). Counts of rifampicin-resistant Salmonella and E. coli or aerobic plate count (APC) and coliform counts were conducted before and after each treatment. All treatments significantly reduced levels of pathogens from the initial inoculation level of 5.0 log(10) CFU/cm2. Treatments including hot water sprays provided mean reductions of initial counts for E. coli O157:H7 and S. typhimurium of 3.7 and 3.8 log, APC reductions of 2.9 log, and coliform and thermotolerant coliform count reductions of 3.3 log. The efficacy of hot water treatments was affected by the carcass surface region, but not by delaying the treatment (30 min) after contaminating the surface. Verification of efficacy of hot water interventions used as critical control points in a hazard analysis critical control point (HACCP) system may be possible using coliform counts.
Physicochemical and Microbiological Qualities’ Assessment of Popular Bangladeshi Mango Fruit Juice
Amin, Ruhul; Rahman, Shafkat S.; Hossain, Mahboob; Choudhury, Naiyyum
2018-01-01
Introduction: Mango juice has always been considered as a delicious, nutritious popular drink, but processed juice may not always be safe due to chemical and microbial risks. Determination of physicochemical and microbiological qualities of some packed mango juices of Bangladesh will help consumers to know the present scenario. Material and Methods: Six commercially available different juice samples were collected from the market. Carbohydrate profiles were determined using HPLC, crude protein content was calculated using the Kjeldahl method and other parameters were determined by standard AOAC methods. Standard culture techniques were followed to assess the total viable count (TVC), E. coli and other fecal coliforms. Results: The highest quantity of monosaccharide (58.88%) was recorded in the AC1ME5 brand, while the lowest in Homemade (5.648%) and MN1GL2 (9.867%). The maximum content of acidity recorded was 0.24% and minimum 0.21%. The TSS content of all samples varied from 19% to 12%. The highest quantity 6.87% and the lowest 3.62% of reducing sugar were recorded. Most of the mango juices were low in protein and very low/negligible in fat content. Total viable count of different types of fruit juices varied from 1×103 - 3×103 CFU/ml. No significant amount of E. coli and fecal coliform was detected. Conclusion: It can be concluded that the locally available mango juices contain a safe level of nutritional and microbial elements for human consumption, but not highly satisfactory. PMID:29785220
Ground-Water Quality in the Upper Susquehanna River Basin, New York, 2004-05
Hetcher-Aguila, Kari K.; Eckhardt, David A.V.
2006-01-01
Water samples were collected from 20 production wells and 13 private residential wells throughout the upper Susquehanna River Basin (upstream from the Pennsylvania border) during the fall of 2004 and the spring of 2005 and analyzed to describe the chemical quality of ground water in the upper basin. Wells were selected to represent areas of greatest ground-water use and highest vulnerability to contamination, and to provide a representative sampling from the entire (4,516 square-mile) upper basin. Samples were analyzed for physical properties, nutrients, inorganic constituents, metals, radionuclides, pesticides, volatile organic compounds, and bacteria. The cations that were detected in the highest concentrations were calcium, magnesium, and sodium; the anions that were detected in the greatest concentrations were bicarbonate, chloride, and sulfate. The predominant nutrient was nitrate, the concentrations of which were greater in samples from sand and gravel aquifers than in samples from bedrock. The metals barium, boron, cobalt, copper, and nickel were detected in every sample; the metals with the highest concentrations were barium, boron, iron, manganese, strontium, and lithium. The pesticide compounds detected most frequently were atrazine, deethylatrazine, alachlor ESA, and two degradation products of metolachlor (metolachlor ESA and metolachlor OA); the compounds detected in highest concentration were metolachlor ESA and OA. Volatile organic compounds were detected in 11 samples, and concentrations of 3 of these compounds exceeded 1 microgram per liter (?g/L). Methyl tert-butyl ether (MTBE), a gasollline additive, was not detected in any sample. Several analytes were found in concentrations that exceeded Federal and New York State water-quality standards, which are typically identical. Chloride concentrations exceeded the U.S. Environmental Protection Agency (USEPA) Secondary Maximum Contaminant Level (SMCL) of 250 milligrams per liter (mg/L) in two samples, and sulfate concentrations exceeded the SMCL of 250 mg/L in one sample. Sodium concentrations exceeded the USEPA Drinking Water Advisory of 60 mg/L in six samples. Nitrate concentrations exceeded the USEPA Maximum Contaminant Level (MCL) of 10 mg/L in one sample and approached this limit (at 9.84 mg/L) in another sample. Barium concentrations exceeded the MCL of 2,000 ?g/L in one sample. Iron concentrations exceeded the SMCL of 300 ?g/L in five samples, and manganese concentrations exceeded the SMCL of 50 ?g/L in 14 samples. Arsenic was detected in seven samples, and the MCL for arsenic (10 ?g/L) was exceeded in two samples. Radon-222 exceeded the proposed MCL of 300 picocuries per liter in 24 samples. Any detection of total coliform or fecal coliform bacteria is considered a violation of New York State health regulations; in this study, total coliform was detected in six samples and fecal coliform was detected in one sample, but Escherichia coli (E. coli) was not detected in any sample.
Patrick, T E; Goodwin, T L; Collins, J A; Wyche, R C; Love, B E
1972-04-01
A comparison of two types of scalders was conducted to determine their effectiveness in reducing bacterial contamination of poultry carcasses. A conventional hot-water scalder and a prototype model of a steam scalder were tested under commercial conditions. Total plate counts from steam-scalded birds were significantly lower than the counts of water-scalded birds immediately after scalding and again after picking. No differences in the two methods could be found after chilling. Coliform counts from steam-scalded birds were significantly lower than the counts from water-scalded birds immediately after scalding. No significant differences in coliform counts were detected when the two scald methods were compared after defeathering and chilling.
Bej, A K; McCarty, S C; Atlas, R M
1991-01-01
Multiplex polymerase chain reaction (PCR) and gene probe detection of target lacZ and uidA genes were used to detect total coliform bacteria and Escherichia coli, respectively, for determining water quality. In tests of environmental water samples, the lacZ PCR method gave results statistically equivalent to those of the plate count and defined substrate methods accepted by the U.S. Environmental Protection Agency for water quality monitoring and the uidA PCR method was more sensitive than 4-methylumbelliferyl-beta-D-glucuronide-based defined substrate tests for specific detection of E. coli. Images PMID:1768116
Chaidez, Cristóbal; Ibarra-Rodríguez, Juan R; Valdez-Torres, José Benigno; Soto, Marcela; Gerba, Charles P; Castro-Del Campo, Nohelia
2016-09-01
In developing countries, rural communities often face the lack of potable water infrastructure and must rely on untreated sources for drinking, which are often contaminated with waterborne pathogens. The use of home water treatment devices is seen as one means of reducing the risk of exposure to waterborne pathogens. The aim of this study was to evaluate the microbiological and physicochemical performance of a simple in-home point-of-use device based on gravity ultrafiltration through an ultrafilter membrane. Twenty-five randomly selected households from 2 rural communities in Culiacán, Mexico, were enrolled. Water samples were collected before and after treatment and during storage for a period of 8 weeks. Heterotrophic bacteria, total coliforms, fecal coliforms, Escherichia coli, and Giardia spp were quantified, as well as various physicochemical parameters. All of the untreated water samples contained high levels of indicator bacteria, but none were detected in the treated water fulfilling the requirements set by the Mexican Norm (NOM-127-SSA1-1994) and the World Health Organization guidelines for drinking water. However, indicator bacteria (fecal coliforms and E coli) were detected in every sample from water stored 24 hours after treatment. This study demonstrated that point-of-use filters using gravity-fed ultrafilters are a low-cost, effective water treatment technology for water of poor microbial quality. However, further identification of the sources and mechanisms by which water is contaminated when stored after treatment will help with designing and implementing better strategies for keeping water safe for domestic use. Copyright © 2016 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.
Effect of land cover, stream discharge, and precipitation on water quality in Puerto Rico
NASA Astrophysics Data System (ADS)
Hall, J. S.; Uriarte, M.
2017-12-01
In 2015, Puerto Rico experienced one of the worst droughts in its history, causing widespread water rationing and sparking concerns for future resources. The drought represents precipitation extremes that provide valuable insight into the effects of land cover (LC), on modulating discharge and water quality indices at varying spatial scales. We used data collected from 38 water quality and 55 precipitation monitoring stations in Puerto Rico from 2005 to 2016, paired with a 2010 land cover map to (1) determine whether temporal variability in discharge, precipitation, or antecedent precipitation was a better predictor of water quality, (2) find the spatial scale where LC has the greatest impact on water quality, and (3) quantify impacts of LC on water quality indices, including dissolved oxygen (mg/L), total nitrogen (mg/L), phosphorous (mg/L), turbidity (NTRU), fecal coliforms (colony units/100mL) and instantaneous discharge (ft3/s). The resulting linear mixed effects models account for between 36-68% of the variance in water quality. Preliminary results indicate that phosphorous and nitrogen were best predicted from instantaneous stream discharge, the log of discharge was the better predictor for turbidity and fecal coliforms, and summed 2 and 14-day antecedent precipitation indices were better predictors for dissolved oxygen and discharge, respectively. Increased urban and pasture area reliably decreased water quality in relation to forest cover, while agriculture and wetlands had little or mixed effects. Turbidity and nitrogen responded to a watershed level LC, while phosphorous, fecal coliforms, and discharge responded to LC in 60 m riparian buffers at the watershed scale. Our results indicate that LC modulates changing precipitation regimes and the ensuing impacts on water quality at a range of spatial scales.
The effectiveness of sewage treatment processes to remove faecal pathogens and antibiotic residues
Hendricks, Rahzia; Pool, Edmund John
2012-01-01
Pathogens and antibiotics enter the aquatic environment via sewage effluents and may pose a health risk to wild life and humans. The aim of this study was to determine the levels of faecal bacteria, and selected antibiotic residues in raw wastewater and treated sewage effluents from three different sewage treatment plants in the Western Cape, South Africa. Sewage treatment plant 1 and 2 use older technologies, while sewage treatment plant 3 has been upgraded and membrane technologies were incorporated in the treatment processes. Coliforms and Escherichia coli (E. coli) were used as bioindicators for faecal bacteria. A chromogenic test was used to screen for coliforms and E. coli. Fluoroquinolones and sulfamethoxazole are commonly used antibiotics and were selected to monitor the efficiency of sewage treatment processes for antibiotic removal. Enzyme Linked Immunosorbent Assays (ELISAs) were used to quantitate antibiotic residues in raw and treated sewage. Raw intake water at all treatment plants contained total coliforms and E. coli. High removal of E. coli by treatment processes was evident for treatment plant 2 and 3 only. Fluoroquinolones and sulfamethoxazole were detected in raw wastewater from all sewage treatment plants. Treatment processes at plant 1 did not reduce the fluoroquinolone concentration in treated sewage effluents. Treatment processes at plant 2 and 3 reduced the fluoroquinolone concentration by 21% and 31%, respectively. Treatment processes at plant 1 did not reduce the sulfamethoxazole concentration in treated sewage effluents. Treatment processes at plant 2 and 3 reduced sulfamethoxazole by 34% and 56%, respectively. This study showed that bacteria and antibiotic residues are still discharged into the environment. Further research needs to be undertaken to improve sewage treatment technologies, thereby producing a better quality treated sewage effluent. PMID:22242882
Noble, M A; Xu, J P; Robertson, G L; Rosenfeld, L K
2006-06-01
Fecal indicator bacteria (FIB) were measured approximately 5 days a week in ankle-depth water at 19 surfzone stations along Huntington Beach and Newport Beach, California, from 1998 to the end of 2003. These sampling periods span the time before and after treated sewage effluent, discharged into the coastal ocean from the local outfall, was disinfected. Bacterial samples were also taken in the vicinity of the outfall during the pre- and post-disinfection periods. Our analysis of the results from both data sets suggest that land-based sources, rather than the local outfall, were the source of the FIB responsible for the frequent closures and postings of local beaches in the summers of 2001 and 2002. Because the annual cycle is the dominant frequency in the fecal and total coliform data sets at most sampling stations, we infer that sources associated with local runoff were responsible for the majority of coliform contamination along wide stretches of the beach. The dominant fortnightly cycle in enterococci at many surfzone sampling stations suggests that the source for these relatively frequent bacteria contamination events in summer is related to the wetting and draining of the land due to the large tidal excursions found during spring tides. Along the most frequently closed section of the beach at stations 3N-15N, the fortnightly cycle is dominant in all FIBs. The strikingly different spatial and spectral patterns found in coliform and in enterococci suggest the presence of different sources, at least for large sections of beach. The presence of a relatively large enterococci fortnightly cycle along the beaches near Newport Harbor indicates that contamination sources similar to those found off Huntington Beach are present, though not at high enough levels to close the Newport beaches.
Wright, Carlee J; Sargeant, Jan M; Edge, Victoria L; Ford, James D; Farahbakhsh, Khosrow; Shiwak, Inez; Flowers, Charlie; Harper, Sherilee L
2017-07-12
One of the highest self-reported incidence rates of acute gastrointestinal illness (AGI) in the global peer-reviewed literature occurs in Inuit communities in the Canadian Arctic. This high incidence of illness could be due, in part, to the consumption of contaminated water, as many northern communities face challenges related to the quality of municipal drinking water. Furthermore, many Inuit store drinking water in containers in the home, which could increase the risk of contamination between source and point-of-use (i.e., water recontamination during storage). To examine this risk, this research characterized drinking water collection and storage practices, identified potential risk factors for water contamination between source and point-of-use, and examined possible associations between drinking water contamination and self-reported AGI in the Inuit community of Rigolet, Canada. The study included a cross-sectional census survey that captured data on types of drinking water used, household practices related to drinking water (e.g., how it was collected and stored), physical characteristics of water storage containers, and self-reported AGI. Additionally, water samples were collected from all identified drinking water containers in homes and analyzed for presence of Escherichia coli and total coliforms. Despite municipally treated tap water being available in all homes, 77.6% of households had alternative sources of drinking water stored in containers, and of these containers, 25.2% tested positive for total coliforms. The use of transfer devices and water dippers (i.e., smaller bowls or measuring cups) for the collection and retrieval of water from containers were both significantly associated with increased odds of total coliform presence in stored water (OR transfer device = 3.4, 95% CI 1.2-11.7; OR dipper = 13.4, 95% CI 3.8-47.1). Twenty-eight-day period prevalence of self-reported AGI during the month before the survey was 17.2% (95% CI 13.0-22.5), which yielded an annual incidence rate of 2.4 cases per person per year (95% CI 1.8-3.1); no water-related risk factors were significantly associated with AGI. Considering the high prevalence of, and risk factors associated with, indicator bacteria in drinking water stored in containers, potential exposure to waterborne pathogens may be minimized through interventions at the household level.
Coliform contamination of a coastal embayment: Sources and transport pathways
Weiskel, P.K.; Howes, B.L.; Heufelder, G.R.
1996-01-01
Fecal bacterial contamination of nearshore waters has direct economic impacts to coastal communities through the loss of shellfisheries and restrictions of recreational uses. We conducted seasonal measurements of fecal coliform (FC) sources and transport pathways contributing to FC contamination of Buttermilk Bay, a shallow embayment adjacent to Buzzards Bay, MA. Typical of most coastal embayments, there were no direct sewage discharges (i.e., outfalls), and fecal bacteria from human, domestic animal, and wildlife pools entered open waters primarily through direct deposition or after transport through surface waters or groundwaters. Direct fecal coliform inputs to bay waters occurred primarily in winter (December-March) from waterfowl, ~33 x 1012 FC yr-1 or ~67% of the total annual loading. Effects of waterfowl inputs on bay FC densities were mitigated by their seasonality, wide distribution across the bay surface, and the apparent limited dispersal from fecal pellets. On-site disposal of sewage by septic systems was the single largest FC source in the watershed-embayment system, 460 x 1012 FC yr-1, but due to attenuation during subsurface transport only a minute fraction, < 0.006 x 1012 FC yr-1, reached bay waters (<0.01% of annual input to bay). Instead, surface water flows, via storm drains and natural streams under both wet- and dry-weather conditions, contributed the major terrestrial input, 12 x 1012 FC yr-1 (24% of annual input), all from animal sources. Since most of the surface water FC inputs were associated with periodic, short-duration rain events with discharge concentrated in nearshore zones, wet-weather flows were found to have a disproportionately high impact on nearshore FC levels. Elution of FC from shoreline deposits of decaying vegetation (wrack) comprised an additional coliform source. Both laboratory and field experiments suggest significant elution of bacteria from wrack, ~3 x 1012 FC yr-1 on a bay-wide basis (6% of annual input), primarily by periodic tidal flooding and possibly by major rain events. Release of coliforms during resuspension of subtidal sediments was estimated to be a minor source in this system (<1.5 x 1012 FC yr-1 or < 3% of annual input), primarily associated with large storm events in the fall and winter. Based upon the relative source strengths and the spatial and temporal patterns of FC input to Buttermilk Bay, it appears that management practices in similar settings should account for migratory waterfowl, but remediation efforts should focus on the redirection of stormwater runoff through the groundwater transport pathway.
Microbiological quality of pastrami and associated surfaces at the point of sale in Kayseri, Turkey.
Yildirim, Y; Ertas Onmaz, N; Gonulalan, Z; Al, S; Yildirim, A; Karadal, F; Hizlisoy, H; Pamuk, Ş
2017-05-01
The aim of this study is to trace the possible relations between the hygienic status of slicing utensils and the microbiological quality of pastrami. A total of 75 pastrami retail markets were visited in Kayseri, Turkey, where the pastrami (a ready-to-eat meat product) is commonly produced and consumed. Sliced pastrami, the cutting board and knife surface swabs were collected from each pastrami retail point to trace possible sources of contamination. Samples were analysed for the presence of total viable counts (TVC), total coliforms, Escherichia coli, members of Enterobacteriaceae, Staphylococcus aureus and Listeria spp. In addition, pastrami samples were analysed for sulphite-reducing Clostridium spp. and Toxoplasma gondii. When compared with the target values of related literatures, a total of 6 (8%) pastrami samples were found unsatisfactory as a result of TVC (5.3%), Enterobacteriaceae (5.3%), E. coli (2.6%), S. aureus (2.6%), Listeria spp. (2.6%) and Listeria monocytogenes (1.3%) contaminations. No T. gondii positivity was observed among the pastrami samples. None of the cutting board and knife surface swabs were found to harbour TVC level >10 3 cfu/cm 2 , E. coli and L. monocytogenes. For the total coliforms, 7 (9.3%) and 5 (6.6%) of cutting board and knife surface swabs were found to exceed the target value (<2.5 cfu/cm 2 ), respectively. No statistically significant correlation was detected between the organisms on pastrami and slicing utensils indicating that pastrami were not cross-contaminated by the contact surfaces. More emphasis needs to be placed for training of food handlers and to apply good hygienic practices at the point of pastrami sale. The conditions at retail points must be monitored and inspections should be tightened to protect public health. Copyright © 2017 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.
Screening candidate water quality indicators for associations with swimming-related illness
ABSTRACT Traditional (culture-based) indicator organisms (e.g. enterococci, fecal and total coliforms) are used to regulate marine beaches for protecting human health. Despite the recent proliferation of new technology, few studies have examined alternatives to this decades...
A new membrane filter (MF) medium, MI agar, recently validated for use in recovering chlorine-damaged total coloiforms (TC) and Escherichia coli from drinking water, was compared to the US Environmental Protection Agency (EPA)-approved MF method(mEndo agar and nutrient agar suppl...
Medeiros, Adriana O.; Missagia, Beatriz S.; Brandão, Luciana R.; Callisto, Marcos; Barbosa, Francisco A. R.; Rosa, Carlos A.
2012-01-01
Yeast communities were assessed in 14 rivers and four lakes from the Doce River basin in Brazil, during the rainy and dry seasons of the years 2000 and 2001. Water samples were collected at the subsurface in all sites. The following physical and chemical parameters were measured: temperature, dissolved oxygen, pH, electrical conductivity, total phosphorus, ortho-phosphate, ammonium, nitrate, nitrite and total nitrogen and the counts of faecal coliforms and heterotrophic bacteria were carried out to characterize the aquatic environmental sampled. The yeast counts were higher in aquatic environments with the highest counts of coliform and heterotrophic bacteria. These environments receive a high influx of domestic and industrial waste. A total of 317 isolates identified in forty eight yeast species were recorded in the sites sampled and the specie Aureobasidium pullulans were found in eleven out of eighteen sites sampled and some opportunistic pathogens such as the yeast species Candida krusei were isolated only in the polluted rivers with a positive correlation with the biotic and abiotic parameters that indicate sewage contamination. PMID:24031990
The quality of drinking water in North Carolina farmworker camps.
Bischoff, Werner E; Weir, Maria; Summers, Phillip; Chen, Haiying; Quandt, Sara A; Liebman, Amy K; Arcury, Thomas A
2012-10-01
The purpose of this study was to assess water quality in migrant farmworker camps in North Carolina and determine associations of water quality with migrant farmworker housing characteristics. We collected data from 181 farmworker camps in eastern North Carolina during the 2010 agricultural season. Water samples were tested using the Total Coliform Rule (TCR) and housing characteristics were assessed using North Carolina Department of Labor standards. A total of 61 (34%) of 181 camps failed the TCR. Total coliform bacteria were found in all 61 camps, with Escherichia coli also being detected in 2. Water quality was not associated with farmworker housing characteristics or with access to registered public water supplies. Multiple official violations of water quality standards had been reported for the registered public water supplies. Water supplied to farmworker camps often does not comply with current standards and poses a great risk to the physical health of farmworkers and surrounding communities. Expansion of water monitoring to more camps and changes to the regulations such as testing during occupancy and stronger enforcement are needed to secure water safety.
Results of testing landspreading of treated municipal wastewater at St. Petersburg, Florida
Reichenbaugh, R.C.; Brown, David P.; Goetz, Carole L.
1979-01-01
Chlorinated secondary-treated effluent was used to irrigate a grassed 4-acre site at rates of 2 and 4 inches per week for periods of 11 and 14 weeks, respectively. Part of the site was drained by tile lines 5 feet below land surface. Irrigation of the drained plot resulted in rapid passage of the applied wastewater through the soil and, consequently, poor nitrogen removal. The rapid percolation permitted nitrification but prevented denitrification. Total phosphorus in the shallow ground water at the site increased from a maximum of 1.4 milligrams per liter before irrigation to as much as 5 milligrams per liter in the ground water 5 feet below land surface. Concentrations of nitrogen and phosphorus did not increase in ground water downgradient from the site, although increased chloride concentrations demonstrated downgradient migration of the applied wastewater. Prior to irrigation, total coliform bacteria were not detected in ground water at the site. After irrigation, total and fecal coliforms were detected in the ground water at the site and downgradient. (Woodard-USGS)
The Quality of Drinking Water in North Carolina Farmworker Camps
Weir, Maria; Summers, Phillip; Chen, Haiying; Quandt, Sara A.; Liebman, Amy K.; Arcury, Thomas A.
2012-01-01
Objectives. The purpose of this study was to assess water quality in migrant farmworker camps in North Carolina and determine associations of water quality with migrant farmworker housing characteristics. Methods. We collected data from 181 farmworker camps in eastern North Carolina during the 2010 agricultural season. Water samples were tested using the Total Coliform Rule (TCR) and housing characteristics were assessed using North Carolina Department of Labor standards. Results. A total of 61 (34%) of 181 camps failed the TCR. Total coliform bacteria were found in all 61 camps, with Escherichia coli also being detected in 2. Water quality was not associated with farmworker housing characteristics or with access to registered public water supplies. Multiple official violations of water quality standards had been reported for the registered public water supplies. Conclusions. Water supplied to farmworker camps often does not comply with current standards and poses a great risk to the physical health of farmworkers and surrounding communities. Expansion of water monitoring to more camps and changes to the regulations such as testing during occupancy and stronger enforcement are needed to secure water safety. PMID:22897558
Water-quality data for the Russian River Basin, Mendocino and Sonoma Counties, California, 2005-2010
Anders, Robert; Davidek, Karl; Stoeckel, Donald M.
2011-01-01
Field measurements included discharge, barometric pressure, dissolved oxygen, pH, specific conductance, temperature, and turbidity. All samples were analyzed for nutrients, major ions, trace metals, total and dissolved organic carbon, organic wastewater compounds, standard bacterial indicators, and the stable isotopes of hydrogen and oxygen. Standard bacterial indicators included total coliform, Escherichia coli, enterococci, and Clostridium perfringens for the period 2005 through 2007, and total and fecal coliform, and enterococci for 2010. In addition, enrichment of enterococci was performed on all surface-water samples collected during summer 2006, for detection of the human-associated enterococcal surface protein in Enterococcus faecium to assess the presence of sewage effluent in the Russian River. Other analyses included organic wastewater compounds of bed sediment samples collected from four Russian River sites during 2005; carbon-13 isotopic values of the dissolved inorganic carbon for surface-water and groundwater samples collected during 2006; human-use pharmaceuticals on Russian River samples collected during 2007 and 2010; and the radiogenic isotopes tritium and carbon-14 for groundwater samples collected during 2008.
The Evolving Role of Coliforms As Indicators of Unhygienic Processing Conditions in Dairy Foods.
Martin, Nicole H; Trmčić, Aljoša; Hsieh, Tsung-Han; Boor, Kathryn J; Wiedmann, Martin
2016-01-01
Testing for coliforms has a long history in the dairy industry and has helped to identify raw milk and dairy products that may have been exposed to unsanitary conditions. Coliform standards are included in a number of regulatory documents (e.g., the U.S. Food and Drug Administration's Grade "A" Pasteurized Milk Ordinance). As a consequence, detection above a threshold of members of this method-defined, but diverse, group of bacteria can result in a wide range of regulatory outcomes. Coliforms are defined as aerobic or facultatively anaerobic, Gram negative, non-sporeforming rods capable of fermenting lactose to produce gas and acid within 48 h at 32-35°C; 19 genera currently include at least some strains that represent coliforms. Most bacterial genera that comprise the coliform group (e.g., Escherichia , Klebsiella , and Serratia ) are within the family Enterobacteriaceae, while at least one genus with strains recognized as coliforms, Aeromonas , is in the family Aeromonadaceae. The presence of coliforms has long been thought to indicate fecal contamination, however, recent discoveries regarding this diverse group of bacteria indicates that only a fraction are fecal in origin, while the majority are environmental contaminants. In the US dairy industry in particular, testing for coliforms as indicators of unsanitary conditions and post-processing contamination is widespread. While coliforms are easily and rapidly detected, and are not found in pasteurized dairy products that have not been exposed to post-processing contamination, advances in knowledge of bacterial populations most commonly associated with post-processing contamination in dairy foods has led to questions regarding the utility of coliforms as indicators of unsanitary conditions for dairy products. For example, Pseudomonas spp. frequently contaminate dairy products after pasteurization, yet they are not detected by coliform tests. This review will address the role that coliforms play in raw and finished dairy products, their sources and the future of this diverse group as indicator organisms in dairy products.
The Evolving Role of Coliforms As Indicators of Unhygienic Processing Conditions in Dairy Foods
Martin, Nicole H.; Trmčić, Aljoša; Hsieh, Tsung-Han; Boor, Kathryn J.; Wiedmann, Martin
2016-01-01
Testing for coliforms has a long history in the dairy industry and has helped to identify raw milk and dairy products that may have been exposed to unsanitary conditions. Coliform standards are included in a number of regulatory documents (e.g., the U.S. Food and Drug Administration’s Grade “A” Pasteurized Milk Ordinance). As a consequence, detection above a threshold of members of this method-defined, but diverse, group of bacteria can result in a wide range of regulatory outcomes. Coliforms are defined as aerobic or facultatively anaerobic, Gram negative, non-sporeforming rods capable of fermenting lactose to produce gas and acid within 48 h at 32–35°C; 19 genera currently include at least some strains that represent coliforms. Most bacterial genera that comprise the coliform group (e.g., Escherichia, Klebsiella, and Serratia) are within the family Enterobacteriaceae, while at least one genus with strains recognized as coliforms, Aeromonas, is in the family Aeromonadaceae. The presence of coliforms has long been thought to indicate fecal contamination, however, recent discoveries regarding this diverse group of bacteria indicates that only a fraction are fecal in origin, while the majority are environmental contaminants. In the US dairy industry in particular, testing for coliforms as indicators of unsanitary conditions and post-processing contamination is widespread. While coliforms are easily and rapidly detected, and are not found in pasteurized dairy products that have not been exposed to post-processing contamination, advances in knowledge of bacterial populations most commonly associated with post-processing contamination in dairy foods has led to questions regarding the utility of coliforms as indicators of unsanitary conditions for dairy products. For example, Pseudomonas spp. frequently contaminate dairy products after pasteurization, yet they are not detected by coliform tests. This review will address the role that coliforms play in raw and finished dairy products, their sources and the future of this diverse group as indicator organisms in dairy products. PMID:27746769
Gehr, Ronald; Wagner, Monika; Veerasubramanian, Priya; Payment, Pierre
2003-11-01
The City of Montreal Wastewater Treatment Plant uses enhanced physicochemical processes (ferric and/or alum coagulation) for suspended solids and phosphorus removal. The objective of this study was to assess the ability of peracetic acid (PAA), UV, or ozone to inactivate the indicator organisms fecal coliforms, Enterococci, MS-2 coliphage, or Clostridium perfringens in the effluent from this plant. PAA doses to reach the target fecal coliform level of 9000 CFU/100mL exceeded 6 mg/L; similar results were obtained for enterococci, and no inactivation of Clostridium perfringens was observed. However a 1-log reduction of MS-2 occurred at PAA doses of 1.5 mg/L and higher. It was expected that this effluent would have a high ozone demand, and would require relatively high UV fluences, because of relatively high effluent COD, iron and suspended solids concentrations, and low UV transmittance. This was confirmed herein. For UV, the inactivation curve for fecal coliforms showed the typical two-stage shape, with the target of 1000 CFU/100 mL (to account for photoreactivation) occurring in the asymptote zone at fluences >20 mJ/cm(2). In contrast, inactivation curves for MS-2 and Clostridium perfringens were linear. Clostridium perfringens was the most resistant organism. For ozone, inactivation was already observed before any residuals could be measured. The transferred ozone doses to reach target fecal coliform levels ( approximately 2-log reduction) were 30-50 mg/L. MS-2 was less resistant, but Clostridium perfringens was more resistant than fecal coliforms. The different behaviour of the four indicator organisms studied, depending on the disinfectant, suggests that a single indicator organism might not be appropriate. The required dose of any of the disinfectants is unlikely to be economically viable, and upstream changes to the plant will be needed.
NASA Astrophysics Data System (ADS)
Desmiarti, Reni; Hazmi, Ariadi; Martynis, Munas; Sutopo, Ulung Muhammad; Li, Fusheng
2018-02-01
Pathogenic bacteria, such as total coliforms (TC), fecal coliforms (FC) and other coliforms (OC), were removed from groundwater by inductively coupled plasma system treatment in continuous flow experiments. The objective of this study is to investigate the effect of flowrate and frequency on the behavior of microorganisms in drinking water treatment using inductively coupled plasma system (ICPS). The results showed that after 120 minutes of ICPS treatment, the removal efficiency with respect to TC, FC and OC decreased with increasing flowrate. The removal efficiency of FC was achieved at 100% in all runs. Compared to FC, the removal efficiencies with respect to TC and FC were lower than those with respect to TC and OC in the following order: FC >OC> TC. The disinfection yield of TC and OC significantly increased when the removal efficiency increased. The electromagnetic flux varied from 8.08±0.46 to 10.54±0.19 W/cm2. The results in the present work can be used to design a new technology for drinking water treatment to remove all pathogenic bacteria without using hazardous chemicals.
Li, Dan; Zeng, Siyu; Gu, April Z; He, Miao; Shi, Hanchang
2013-07-01
Disinfection of reclaimed water prior to reuse is important to prevent the transmission of pathogens. Chlorine is a widely utilized disinfectant and as such is a leading contender for disinfection of reclaimed water. To understand the risks of chlorination resulting from the potential selection of pathogenic bacteria, the inactivation, reactivation and regrowth rates of indigenous bacteria were investigated in reclaimed water after chlorine disinfection. Inactivation of total coliforms, Enterococcus and Salmonella showed linear correlations, with constants of 0.1384, 0.1624 and 0.057 L/(mg.min) and R2 of 0.7617, 0.8316 and 0.845, respectively. However, inactivation of total viable cells by measurement of metabolic activity typically showed a linear correlation at lower chlorine dose (0-22 (mg-min)/L), and a trailing region with chlorine dose increasing from 22 to 69 (mg.min)/L. Reactivation and regrowth of bacteria were most likely to occur after exposure to lower chlorine doses, and extents of reactivation decreased gradually with increasing chlorine dose. In contrast to total coliforms and Enterococcus, Salmonella had a high level of regrowth and reactivation, and still had 2% regrowth even after chlorination of 69 (mg.min)/L and 24 hr storage. The bacterial compositions were also significantly altered by chlorination and storage of reclaimed water, and the ratio of Salmonella was significantly increased from 0.001% to 0.045% after chlorination of 69 (mg.min)/L and 24 hr storage. These trends indicated that chlorination contributes to the selection of chlorine-resistant pathogenic bacteria, and regrowth of pathogenic bacteria after chlorination in reclaimed water with a long retention time could threaten public health security during wastewater reuse.
Vigil, Karen J; Jiang, Zhi-Dong; Chen, Jaclyn J; Palumbo, Kathryn L; Galbadage, Thushara; Brown, Eric L; Yiang, Jing; Koo, Hoonmo; DuPont, Margaret W; Ericsson, Charles; Adachi, Javier A; DuPont, Herbert L
2009-04-01
Bacterial enteropathogens acquired from contaminated food are the principal causes of travelers' diarrhea (TD). We evaluated desserts obtained from popular restaurants in the tourist city of Guadalajara, Mexico, and Houston, Texas, to determine coliform and Escherichia coli contamination levels and presence of diarrheagenic E. coli known to be important in TD. Contamination for all organisms was seen for desserts served in Guadalajara restaurants. Desserts should be considered as potentially risky foods for development of TD among international visitors to developing regions of the world.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-12
... White Bayou (East Baton Rouge Parish) (Scenic). 040103 Comite River-- Fecal Coliform. Entrance of White.... Amite River Diversion Canal to mouth at Lake Maurepas (Scenic). 040903 Bayou Cane-- TSS. Headwaters to U...
40 CFR 142.14 - Records kept by States.
Code of Federal Regulations, 2010 CFR
2010-07-01
... alternative filtration technology, in combination with disinfection treatment, consistently achieves 99.9... of viruses, may use such alternative filtration technology, shall be kept until the decision is... history of total coliform contamination in its current configuration and had a sanitary survey conducted...
33 CFR 159.127 - Safety coliform count: Recirculating devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Safety coliform count....127 Safety coliform count: Recirculating devices. Thirty-eight of forty samples of flush fluid from a recirculating device must have less than 240 fecal coliform bacteria per 100 milliliters. These samples must be...
Lewis, D J; Atwill, E R; Lennox, M S; Hou, L; Karle, B; Tate, K W
2005-08-01
How and where to improve water quality within an agricultural watershed requires data at a spatial scale that corresponds with individual management decision units on an agricultural operation. This is particularly true in the context of water quality regulations, such as Total Maximum Daily Loads (TMDLs), that identify agriculture as one source of non-point source pollution through larger tributary watershed scale and above and below water quality investigations. We have conducted a systems approach study of 10 coastal dairies and ranches to document fecal coliform concentration and loading to surface waters at the management decision unit scale. Water quality samples were collected on a storm event basis from loading units that included: manure management systems; gutters; storm drains; pastures; and corrals and lots. In addition, in-stream samples were collected above and below the dairy facilities and from a control watershed, managed for light grazing and without a dairy facility or human residence and corresponding septic system. Samples were analyzed for fecal coliform concentration by membrane filtration. Instantaneous discharge was measured for each collected sample. Storm runoff was also calculated using the curve number method (SCS, 1985). Results for a representative dairy as well as the entire 10 dairy data set are presented. Fecal coliform concentrations demonstrate high variability both within and between loading units. Fecal coliform concentrations for pastures range from 206 to 2,288,888 cfu/100 ml and for lots from 1,933 to 166,105,000 cfu/100 ml. Mean concentrations for pastures and lots are 121,298 (SE = 62,222) and 3,155,584 (SE = 1,902,713) cfu/100 ml, respectively. Fecal coliform load from units of concentrated animals and manure are significantly more than units such as pastures while storm flow amounts were significantly less. Compared with results from earlier tributary scale studies in the watershed, this systems approach has generated water quality data that is beneficial for management decisions because of its scale and representation of current management activities. These results are facilitating on-farm changes through the cooperative efforts of dairy managers, regulatory agency staff, and sources of technical and financial assistance.
Cobbina, Samuel J; Anyidoho, Louis Y; Nyame, Frank; Hodgson, I O A
2010-08-01
This study was primarily aimed at investigating the physicochemical and microbial quality of water in 14 such dugouts from five districts in the northern region of Ghana. Results obtained suggest that except for colour, turbidity, total iron and manganese, many physicochemical parameters were either within or close to the World Health Organisation's acceptable limits for drinking water. Generally, colour ranged from 5 to 750 Hz (mean 175 Hz), turbidity from 0.65 to 568 nephelometric turbidity units (NTU; mean 87.9 NTU), total iron from 0.07 to 7.85 mg/L (mean 1.0 mg/L) and manganese from 0.03 to 1.59 mg/L (mean 0.50 mg/L). Coliform counts in water from all the dugouts in both wet and dry seasons were, however, above the recommended limits for drinking water. Total and faecal coliforms ranged from 125 to 68,000 colony forming units (cfu)/100 mL (mean 10,623 cfu/100 mL) and <1 to 19,000 cfu/100 mL (mean 1,310 cfu /100 mL), respectively. The poor microbial quality, as indicated by the analytically significant presence of coliform bacteria in all samples of dugout water, strongly suggests susceptibility and exposure to waterborne diseases of, and consequent health implications on, the many people who continuously patronise these vital water resources throughout the year. In particular, more proactive sustainable water management options, such as introduction to communities of simple but cost-effective purification techniques for water drawn from dugouts for drinking purposes, education and information dissemination to the water users to ensure environmentally hygienic practices around dugouts, may be needed.
Microbiological monitoring of marine recreational waters in southern California.
Schiff, K C; Weisberg, S B; Dorsey, J H
2001-01-01
An inventory was conducted to assess the number, type, spatial distribution, and costs of microbiological monitoring programs in southern California marine waters from Point Conception to the US/Mexico International Border. The location of each sampling site was determined using global positioning system (GPS), and estimates of geographic coverage were determined using geographic information system (GIS) techniques. Twenty-one programs conducted 87,007 tests annually at 576 sites in the study area. The largest number of sites was sampled in Orange County, whereas the largest number of analyses was performed in Los Angeles County because monitoring programs in this area focused on daily monitoring. Fifteen of the 21 programs were managed by National Pollutant Discharge Elimination System (NPDES) permitted sewage effluent dischargers who sampled both offshore and shoreline waters and typically tested for three indicator bacteria (total coliform, fecal coliform, and enterococcus). Their combined efforts comprised 82% of all of the microbiological indicator analyses conducted on an annual basis. Five of the remaining monitoring organizations were public health agencies, which typically focus their efforts on testing only total coliforms. Laboratory methodology also varied considerably, with NPDES permittees predominantly utilizing membrane filtration while public health agencies generally used multiple tube fermentation or premanufactured test kits. Nearly three quarters of all the effort expended in southern California occurred along the shoreline as opposed to offshore locations. Two thirds of this shoreline effort was focused on high-use sandy beaches and in proximity to perennial fresh-water outlets (storm drains and creeks). Most sampling occurred at a set of fixed sites that were revisited frequently, but only represented about 7% of the total shoreline. We estimated that roughly $3 million is spent annually on monitoring bathing water quality in southern California, exceeding that spent in any other part of the country.
Messner, Michael J; Berger, Philip; Javier, Julie
2017-06-01
Public water systems (PWSs) in the United States generate total coliform (TC) and Escherichia coli (EC) monitoring data, as required by the Total Coliform Rule (TCR). We analyzed data generated in 2011 by approximately 38,000 small (serving fewer than 4101 individuals) undisinfected public water systems (PWSs). We used statistical modeling to characterize a distribution of TC detection probabilities for each of nine groupings of PWSs based on system type (community, non-transient non-community, and transient non-community) and population served (less than 101, 101-1000 and 1001-4100 people). We found that among PWS types sampled in 2011, on average, undisinfected transient PWSs test positive for TC 4.3% of the time as compared with 3% for undisinfected non-transient PWSs and 2.5% for undisinfected community PWSs. Within each type of PWS, the smaller systems have higher median TC detection than the larger systems. All TC-positive samples were assayed for EC. Among TC-positive samples from small undisinfected PWSs, EC is detected in about 5% of samples, regardless of PWS type or size. We evaluated the upper tail of the TC detection probability distributions and found that significant percentages of some system types have high TC detection probabilities. For example, assuming the systems providing data are nationally-representative, then 5.0% of the ∼50,000 small undisinfected transient PWSs in the U.S. have TC detection probabilities of 20% or more. Communities with such high TC detection probabilities may have elevated risk of acute gastrointestinal (AGI) illness - perhaps as great or greater than the attributable risk to drinking water (6-22%) calculated for 14 Wisconsin community PWSs with much lower TC detection probabilities (about 2.3%, Borchardt et al., 2012). Published by Elsevier GmbH.
Evaluation of Porcelain Cup Soil Water Samplers for Bacteriological Sampling1
Dazzo, Frank B.; Rothwell, Donald F.
1974-01-01
The validity of obtaining soil water for fecal coliform analyses by porcelain cup soil water samplers was examined. Numbers from samples of manure slurry drawn through porcelain cups were reduced 100- to 10,000,000-fold compared to numbers obtained from the external manure slurry, and 65% of the cups yielded coliform-free samples. Fecal coliforms adsorbed to cups apparently were released, thus influencing the counts of subsequent samples. Fecal coliforms persisted in soil water samplers buried in soil and thus could significantly influence the coliform counts of water samples obtained a month later. These studies indicate that porcelain cup soil water samplers do not yield valid water samples for fecal coliform analyses. Images PMID:16349998
Effect of dredge spoil deposition on fecal coliform counts in sediments at a disposal site.
Babinchak, J A; Graikoski, J T; Dudley, S; Nitkowski, M F
1977-01-01
The most-probable-number of fecal coliforms in sediments was monitored at the New London dump site in Long Island Sound during the deposition of dredge spoil from the Thames River. Although the geometric mean for fecal coliforms at five stations in the river was 14,000/100 ml before dredging commenced, the deposition of this material did not increase the incidence of fecal coliforms at 17 spoil stations and 13 control stations in the disposal and surrounding areas. Fecal coliforms appear to occur only in the surface sediment material and are diluted by the subsurface material during the dredging operation. Fecal coliform analyses of bottom waters during high and low tides indicated that the flow of water from the Thames River played a major role in determining the most-probable-number of fecal coliforms in the sediments at the disposal site. PMID:329761
Iranpour, Reza; Cox, Huub H J
2006-09-01
The U.S. Environmental Protection Agency (U.S. EPA) Part 503 Biosolids Rule requires the fecal coliform (indicator) or Salmonella species (pathogen) density requirements for Class A biosolids to be met at the last point of plant control (truck-loading facility and/or farm for land application). The three Southern Californian wastewater treatment plants in this study produced biosolids by thermophilic anaerobic digestion and all met the Class A limits for both fecal coliforms and Salmonella sp. in the digester outflow biosolids. At two plants, however, a recurrence of fecal coliforms was observed in postdigestion biosolids, which caused exceedance of the Class A limit for fecal coliforms at the truck-loading facility and farm for land application. Comparison of observations at the three plants and further laboratory tests indicated that the recurrence of fecal coliforms can possibly be related to the following combination of factors: (1) incomplete destruction of fecal coliforms during thermophilic anaerobic digestion, (2) contamination of Class A biosolids with fecal coliforms from external sources during postdigestion, (3) a large drop of the postdigestion biosolids temperature to below the maximum for fecal coliform growth, (4) an unknown effect of biosolids dewatering in centrifuges. At Hyperion Treatment Plant (City of Los Angeles, California), fecal coliform recurrence could be prevented by the following: (1) complete conversion to thermophilic operation to exclude contamination by mesophilically digested biosolids and (2) insulation and electrical heat-tracing of postdigestion train for maintaining a high biosolids temperature in postdigestion.
Ndounla, J; Pulgarin, C
2014-09-15
The photo-disinfection of water from two different wells (W1, pH: 4.6-5.1 ± 0.02) and (W2 pH: 5.6-5.7 ± 0.02) was carried out during the rainy season at Ouagadougou-Burkina Faso, West Africa. The weather variation during the rainy season significantly affects the photo-disinfection processes (solar disinfection and photo-Fenton). The dilution of the water by rainwater highly affected the chemical composition of the wells' water used in this study; very low iron contents Compared to the ones recorded during the dry season were recorded in all water samples. Both photo-disinfection processes were used to treat 25 L of water in a compound parabolic collector (CPC). None of them have shown the total inactivation of both wild enteric bacteria strains (total coliforms/E. coli and Salmonella spp.) involved in the treatment. However, the total coliforms/E. coli strains were totally inactivated during the exposure under most of the photo-Fenton treatment. Also, the remaining strains, especially those of Salmonella spp. were achieved during the subsequent 24h of dark storage under the action of the Fenton process. Under uniquely solar radiation, total inactivation was recorded only in the total coliforms/E. coli strains. The impact of the available irradiance on the efficiency of the photo-Fenton disinfection of natural water was highlighted during the exposure under high intermittent solar radiation. The impact of the HCO3(-) concentration of both wells' water on the evolution of the pH during the photo-disinfection was recorded. Drastic decrease was noticed after the initial fast increase in presence of low HCO3(-) concentration while a steady state was observed after the increase in presence of higher concentration. The redox activities of the nitrogen components of the water during both photo-disinfection processes have led to increased concentration of nitrite in all the cases and variations were noticed in that of nitrate and ammonia. Copyright © 2014 Elsevier B.V. All rights reserved.
Hwang, Chiu-Chu; Lin, Chia-Min; Kung, Hsien-Feng; Huang, Ya-Ling; Hwang, Deng-Fwu; Su, Yi-Cheng; Tsai, Yung-Hsiang
2012-11-15
The effects of salt concentrations (0-15.0%) and drying methods on the quality of dried milkfish were studied. The results showed that the levels of aerobic plate counts, total coliform, water activity, moisture contents, total volatile basic nitrogen (TVBN) and thiobarbituric acid (TBA) of the dried milkfish samples prepared with the same drying method decreased with increased salt concentrations. The samples prepared with the cold-air drying method had better quality in term of lower TVBN and TBA values than those of samples prepared with other drying methods. The histamine contents in all samples, except two, prepared with various salt concentrations by different drying methods were less than 1.9 mg/100 g. Two unsalted samples prepared with hot-air drying at 35 °C and sun drying methods were found to contain histamine at levels of 249.7 and 67.4 mg/100 g, respectively, which were higher than the potential hazard level of 50 mg/100 g. Copyright © 2012 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Skaggs, B.E.
1995-07-01
The Environmental Protection Agency staff published the final storm water regulation on November 16, 1990. The storm water regulation is included in the National Pollutant Discharge Elimination System (NPDES) regulations. It specifies the permit application requirements for certain storm water discharges such as industrial activity or municipal separate storm sewers serving populations of 100,000 or greater. Storm water discharge associated with industrial activity is discharge from any conveyance used for collecting and conveying storm water that is directly related to manufacturing, processing, or raw material storage areas at an industrial plant. Quantitative testing data is required for these discharges. Anmore » individual storm water permit application was completed and submitted to Tennessee Department of Environment and Conservation (TDEC) personnel in October 1992. After reviewing this data in the permit application, TDEC personnel expressed concern with the fecal coliform levels at many of the outfalls. The 1995 NPDES Permit (Part 111-N, page 44) requires that an investigation be conducted to determine the validity of this data. If the fecal coliform data is valid, the permit requires that a report be submitted indicating possible causes and proposed corrective actions.« less
Teramura, H; Sota, K; Iwasaki, M; Ogihara, H
2017-07-01
Sanita-kun™ CC (coliform count) and EC (Escherichia coli/coliform count), sheet quantitative culture systems which can avoid chromogenic interference by lactase in food, were evaluated in comparison with conventional methods for these bacteria. Based on the results of inclusivity and exclusivity studies using 77 micro-organisms, sensitivity and specificity of both Sanita-kun™ met the criteria for ISO 16140. Both media were compared with deoxycholate agar, violet red bile agar, Merck Chromocult™ coliform agar (CCA), 3M Petrifilm™ CC and EC (PEC) and 3-tube MPN, as reference methods, in 100 naturally contaminated food samples. The correlation coefficients of both Sanita-kun™ for coliform detection were more than 0·95 for all comparisons. For E. coli detection, Sanita-kun™ EC was compared with CCA, PEC and MPN in 100 artificially contaminated food samples. The correlation coefficients for E. coli detection of Sanita-kun™ EC were more than 0·95 for all comparisons. There were no significant differences in all comparisons when conducting a one-way analysis of variance (anova). Both Sanita-kun™ significantly inhibited colour interference by lactase when inhibition of enzymatic staining was assessed using 40 natural cheese samples spiked with coliform. Our results demonstrated Sanita-kun™ CC and EC are suitable alternatives for the enumeration of coliforms and E. coli/coliforms, respectively, in a variety of foods, and specifically in fermented foods. Current chromogenic media for coliforms and Escherichia coli/coliforms have enzymatic coloration due to breaking down of chromogenic substrates by food lactase. The novel sheet culture media which have film layer to avoid coloration by food lactase have been developed for enumeration of coliforms and E. coli/coliforms respectively. In this study, we demonstrated these media had comparable performance with reference methods and less interference by food lactase. These media have a possibility not only to be useful alternatives but also to contribute for accurate enumeration of these bacteria in a variety of foods, and specifically in fermented foods. © 2017 The Society for Applied Microbiology.
Escherichia coli: the best biological drinking water indicator for public health protection.
Edberg, S C; Rice, E W; Karlin, R J; Allen, M J
2000-01-01
Public health protection requires an indicator of fecal pollution. It is not necessary to analyse drinking water for all pathogens. Escherichia coli is found in all mammal faeces at concentrations of 10 log 9(-1), but it does not multiply appreciably in the environment. In the 1890s, it was chosen as the biological indicator of water treatment safety. Because of method deficiencies, E. coli surrogates such as the 'fecal coliform' and total coliforms tests were developed and became part of drinking water regulations. With the advent of the Defined Substrate Technology in the late 1980s, it became possible to analyse drinking water directly for E. coli (and, simultaneously, total coliforms) inexpensively and simply. Accordingly, E. coli was re-inserted in the drinking water regulations. E. coli survives in drinking water for between 4 and 12 weeks, depending on environmental conditions (temperature, microflora, etc.). Bacteria and viruses are approximately equally oxidant-sensitive, but parasites are less so. Under the conditions in distribution systems, E. coli will be much more long-lived. Therefore, under most circumstances it is possible to design a monitoring program that permits public health protection at a modest cost. Drinking water regulations currently require infrequent monitoring which may not adequately detect intermittent contamination events; however, it is cost-effective to markedly increase testing with E. coli to better protect the public's health. Comparison with other practical candidate fecal indicators shows that E. coli is far superior overall.
Müller, H E
1990-10-01
The prevention of possible outbreaks as they occurred hundred years ago is still the object of the control of drinking water by the EC-guideline and the Drinking Water Regulations, respectively. At that time, the principle of faecal indicator bacteria was developed and it proved very useful. Now, however, drinking water is no longer supplied by wells but by plants. In comparison with the situation during the last century the relative risks of infectious diseases by faecal organisms are now drastically lower. An intelligent strategy of prevention of drinking water epidemics has to take into consideration that enteropathogens have become too rare so that it is hardly possible to detect them by the frequently occurring faecal markers E. coli and total coliforms. The alternative is the control of the "good manufacturing practices" (GMP) during the processing of drinking water. The colony counts seem to be better markers than the coliforms. Today, more than 90 per cent of infections by drinking water are due to legionellas and ubiquitous mycobacteria occurring in warm water. Therefore, warm water has to be included in the normal control. Furthermore, legionellae and ubiquitous mycobacteria should be tested regularly. Against that, the investigation of total coliforms and/or faecal streptococci seems superfluous. Finally, the future safety of drinking water demands the investigation of at least two additional chemical contaminants, i.e. asbestos and radon, whereas the cyanide test does not appear necessary.
78 FR 10269 - National Primary Drinking Water Regulations: Revisions to the Total Coliform Rule
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-13
... agencies incur the remaining costs. Abbreviations Used in This Document AGI--Acute Gastrointestinal Illness AIDS--Acquired Immune Deficiency Syndrome AIP--Agreement in Principle AWWA--American Water Works... Analysis HUS--Hemolytic Uremic Syndrome ICR--Information Collection Request IESWTR--Interim Enhanced...
EFFECTS OF CHANGING DISINFECTANTS ON LEAD AND COPPER RELEASE– A REVIEW
More utilities are using chloramines in place of free chlorine for greater residual stability and better compliance with both the Total Coliform Rule (TCR) and more stringent requirements of the Disinfectants/Disinfection By-Products Rule (D/DBPR). However, new information about ...
Tertiary treatment using microfiltration and UV disinfection for water reclamation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jolis, D.; Hirano, R.; Pitt, P.
Microfiltration and UV disinfection are two alternative technologies for water reclamation. The results of a pilot study combining these two processes are presented. In addition to producing filtrate turbidites averaging 0.06 nephelometric turbidity units, microfiltration was an effective barrier to pathogens, demonstrating average log reductions of 4.5 for total coliforms and 2.9 for MS2 bacteriophage. Ultraviolet disinfection following microfiltration reliably met the California Wastewater Reclamation Criteria (Title 22) total coliform standard of 2.2 colony-forming units/100 mL at a UV dose of 450 J/m{sup 2}. The MS2 bacteriophage standard, which requires a 5-log reduction, was achieved by microfiltration and a UVmore » dose of 880 J/m{sup 2}. A model of the kinetics of inactivation of MS2 bacteriophage was used in further analysis of disinfection data. The model indicated that considerable backmixing occurred in the pilot UV disinfection unit, and observed UV doses could be reduced with improved hydraulics.« less
Rotary drum composting of vegetable waste and tree leaves.
Kalamdhad, Ajay S; Singh, Yatish K; Ali, Muntjeer; Khwairakpam, Meena; Kazmi, A A
2009-12-01
High rate composting studies on institutional waste, i.e. vegetable wastes, tree leaves, etc., were conducted on a demonstration-scale (3.5 m(3)) rotary drum composter by evaluating changes in some physico-chemical and biological parameters. During composting, higher temperature (60-70 degrees C) at inlet zone and (50-60 degrees C) at middle zone were achieved which resulted in high degradation in the drum. As a result, all parameters including TOC, C/N ratio, CO(2) evolution and coliforms were decreased significantly within few days of composting. Within a week period, quality compost with total nitrogen (2.6%) and final total phosphorus (6 g/kg) was achieved; but relatively higher final values of fecal coliforms and CO(2) evolution, suggested further maturation. Thus, two conventional composting methods namely windrow (M1) and vermicomposting (M2) tried for maturation of primary stabilized compost. By examining these methods, it was suggested that M2 was found suitable in delivering fine grained, better quality matured compost within 20 days of maturation period.
Risk Communication of Groundwater Quality in Northern Malawi, Africa
NASA Astrophysics Data System (ADS)
Holm, R.
2011-12-01
Malawi lies in Africa's Great Rift Valley. Its western border is defined by Lake Malawi, the third largest lake in Africa. Over 80% of Malawians live in rural areas and 90% of the labor force is associated with agriculture. More than half of the population lives below the poverty line. Area characteristics indicate a high likelihood of nitrate and total coliform in community drinking water. Infants exposed to high nitrate are at risk of developing methemoglobinemia. In addition, diarrheal diseases from unsafe drinking water are one of the top causes of mortality in children under five. Without sufficient and sustainable supplies of clean water, these challenges will continue to threaten Malawi's ability to overcome the devastating impact of diarrheal diseases on its population. Therefore, Malawi remains highly dependent on outside assistance and influence to reduce or eliminate the threat posed by unsafe drinking water. This research presents a literature review of nitrate and total coliform groundwater quality and a proposed risk communication plan for drinking water in northern Malawi.
Awaleh, Mohamed Osman; Ahmed, Moussa Mahdi; Soubaneh, Youssouf Djibril; Hoch, Farhan Bouraleh; Bouh, Samatar Mohamed; Dirieh, Elias Said
2013-01-01
The purpose of this paper is to establish the feasibility of recovering discarded reverse osmosis (RO) membranes in order to reduce the salinity of domestic treated wastewater. This study shows that the reuse of RO membranes is of particular interest for arid countries having naturally high mineralized water such as Djibouti. The pilot desalination unit reduces the electrical conductivity, the turbidity and the total dissolved salt respectively at 75-85, 96.7 and 95.4%. The water produced with this desalination unit contains an average of 254 cfu/100 mL total coliforms and 87 cfu/100 mL fecal coliforms. This effluent meets the World Health Organization standards for treated wastewater reuse for agricultural purposes. The annual cost of the desalination unit was evaluated as US $/m(3) 0.82, indicating the relatively high cost of this process. Nevertheless, such processes are required to produce an effluent, with a high reuse potential.
Chloroxyanion Residue on Seeds and Sprouts after Chlorine Dioxide Sanitation of Alfalfa Seed.
Smith, David J; Herges, Grant R
2018-02-28
The effects of a 6-h chlorine dioxide sanitation of alfalfa seed (0, 50, 100, and 200 mg/kg seed) on total coliform bacteria, seed germination, and the presence of chlorate and perchlorate residues in seed rinse, seed soak, and alfalfa sprouts was determined. Chlorate residues in 20,000 mg/L calcium hypochlorite, commonly used to disinfect seed, were quantified. Chlorine dioxide treatment reduced (P < 0.05) total coliforms on seeds with no effect (P > 0.05) on germination. Dose-dependent sodium chlorate residues were present in seed rinse (4.1 to 31.2 μg/g seed) and soak (0.7 to 8.3 μg/g seed) waters, whereas chlorate residues were absent (LOQ 5 ng/g) in sprouts, except for 2 of 5 replicates from the high chlorine dioxide treatment. Copious chlorate residues were present (168 to 1260 mg/L) in freshly prepared 20,000 mg/L calcium hypochlorite solution, and storage at room temperature increased chlorate residues significantly (P < 0.01).
Microbiological Safety of Kitchen Sponges Used in Food Establishments
Bacha, Ketema
2016-01-01
Kitchen sponges are among the possible sources of contaminants in food establishments. The main purpose of the current study was, therefore, to assess the microbiological safety of sponges as it has been used in selected food establishments of Jimma town. Accordingly, the microbiological safety of a total of 201 kitchen sponges randomly collected from food establishments was evaluated against the total counts of aerobic mesophilic bacteria (AMB), Enterobacteriaceae, coliforms, and yeast and molds. The mean counts of aerobic mesophilic bacteria ranged from 7.43 to 12.44 log CFU/mm3. The isolated genera were dominated by Pseudomonas (16.9%), Bacillus (11.1%), Micrococcus (10.6%), Streptococcus (7.8%), and Lactobacillus (6%) excluding the unidentified Gram positive rods (4.9%) and Gram negative rods (9.9%). The high microbial counts (aerobic mesophilic bacteria, coliforms, Enterobacteriaceae, and yeast and molds) reveal the existence of poor kitchen sponge sanitization practice. Awareness creation training on basic hygienic practices to food handlers and periodic change of kitchen sponges are recommended. PMID:27840819
Patrick, Thomas E.; Goodwin, T. L.; Collins, J. A.; Wyche, R. C.; Love, B. E.
1972-01-01
A comparison of two types of scalders was conducted to determine their effectiveness in reducing bacterial contamination of poultry carcasses. A conventional hot-water scalder and a prototype model of a steam scalder were tested under commercial conditions. Total plate counts from steam-scalded birds were significantly lower than the counts of water-scalded birds immediately after scalding and again after picking. No differences in the two methods could be found after chilling. Coliform counts from steam-scalded birds were significantly lower than the counts from water-scalded birds immediately after scalding. No significant differences in coliform counts were detected when the two scald methods were compared after defeathering and chilling. PMID:4553146
Onodera, Takashi; Takayama, Daisuke; Ohashi, Akiyoshi; Yamaguchi, Takashi; Uemura, Shigeki; Harada, Hideki
2016-10-01
Resilience to process outages is an essential requirement for sustainable wastewater treatment systems in developing countries. In this study, we evaluated the ability of a full-scale down-flow hanging sponge (DHS) reactor to recover after a 10-day outage. The DHS tested in this study uses polyurethane sponge as packing material. This full-scale DHS reactor has been tested over a period of about 4 years in India with a flow rate of 500 m(3)/day. Water was not supplied to the DHS reactor that was subjected to the 10-day outage; however, the biomass did not dry out because the sponge was able to retain enough water. Soon after the reactor was restarted, a small quantity of biomass, amounting to only 0.1% of the total retained biomass, was eluted. The DHS effluent achieved satisfactory removal of suspended solids, chemical oxygen demand, and ammonium nitrogen within 90, 45, and 90 min, respectively. Conversely, fecal coliforms in the DHS effluent did not reach satisfactory levels within 540 min; instead, the normal levels of fecal coliforms were achieved within 3 days. Overall, the tests demonstrated that the DHS reactor was sufficiently robust to withstand long-term outages and achieved steady state soon after restart. This reinforces the suitability of this technology for developing countries. Copyright © 2016 Elsevier Ltd. All rights reserved.
Changes in water quality in the Owabi water treatment plant in Ghana
NASA Astrophysics Data System (ADS)
Akoto, Osei; Gyamfi, Opoku; Darko, Godfred; Barnes, Victor Rex
2017-03-01
The study was conducted on the status of the quality of water from the Owabi water treatment plant that supplies drinking water to Kumasi, a major city in Ghana, to ascertain the change in quality of water from source to point-of-use. Physico-chemical, bacteriological water quality parameters and trace metal concentration of water samples from five different treatment points from the Owabi water treatment plant were investigated. The raw water was moderately hard with high turbidity and colour that exceeds the WHO guideline limits. Nutrient concentrations were of the following order: NH3 < NO2 - < NO3 - < PO4 3- < SO4 2- and were all below WHO permissible level for drinking water in all the samples at different stages of treatment. Trace metal concentrations of the reservoir were all below WHO limit except chromium (0.06 mg/L) and copper (0.24 mg/L). The bacteriological study showed that the raw water had total coliform (1,766 cfu/100 mL) and faecal coliform (257 cfu/100 mL) that exceeded the WHO standard limits, rendering it unsafe for domestic purposes without treatment. Colour showed strong positive correlation with turbidity ( r = 0.730), TSS ( r ≥ 0.922) and alkalinity (0.564) significant at p < 0.01. The quality of the treated water indicates that colour, turbidity, Cr and Cu levels reduced and fall within the WHO permissible limit for drinking water. Treatment process at the water treatment plant is adjudged to be good.
Græsbøll, Kaare; Damborg, Peter; Mellerup, Anders; Herrero-Fresno, Ana; Larsen, Inge; Holm, Anders; Nielsen, Jens Peter; Christiansen, Lasse Engbo; Angen, Øystein; Ahmed, Shahana
2017-01-01
ABSTRACT This study describes the results of a randomized clinical trial investigating the effect of oxytetracycline treatment dose and mode of administration on the selection of antibiotic-resistant coliform bacteria in fecal samples from nursery pigs. Nursery pigs (pigs of 4 to 7 weeks of age) in five pig herds were treated with oxytetracycline for Lawsonia intracellularis-induced diarrhea. Each group was randomly allocated to one of five treatment groups: oral flock treatment with a (i) high (20 mg/kg of body weight), (ii) medium (10 mg/kg), or (iii) low (5 mg/kg) dose, (iv) oral pen-wise (small-group) treatment (10 mg/kg), and (v) individual intramuscular injection treatment (10 mg/kg). All groups were treated once a day for 5 days. In all groups, treatment caused a rise in the numbers and proportions of tetracycline-resistant coliform bacteria right after treatment, followed by a significant drop by the time that the pigs left the nursery unit. The counts and proportions of tetracycline-resistant coliforms did not vary significantly between treatment groups, except immediately after treatment, when the highest treatment dose resulted in the highest number of resistant coliforms. A control group treated with tiamulin did not show significant changes in the numbers or proportions of tetracycline-resistant coliforms. Selection for tetracycline-resistant coliforms was significantly correlated to selection for ampicillin- and sulfonamide-resistant strains but not to selection for cefotaxime-resistant strains. In conclusion, the difference in the dose of oxytetracycline and the way in which the drug was applied did not cause significantly different levels of selection of tetracycline-resistant coliform bacteria under the conditions tested. IMPORTANCE Antimicrobial resistance is a global threat to human health. Treatment of livestock with antimicrobials has a direct impact on this problem, and there is a need to improve the ways that we use antimicrobials in livestock production. We hypothesized that antibiotic resistance development following treatment of diarrhea in nursery pigs could be reduced either by lowering the dose of oxytetracycline or by replacing the commonly used practice of flock treatment with individual or small-group treatments, since this would reduce the number of pigs treated. However, the study showed no significant difference between treatment groups with respect to the number or proportion of tetracycline-resistant coliforms selected. The most important conclusion is that under practical field conditions, there will be no added value, in terms of lowering resistance development, by exchanging flock treatment for individual or small-group treatment of nursery pigs. The reason for the lack of an effect of single-animal treatment is probably that such animals share the environment with treated animals and take up resistant bacteria from the environment. PMID:28389548
Græsbøll, Kaare; Damborg, Peter; Mellerup, Anders; Herrero-Fresno, Ana; Larsen, Inge; Holm, Anders; Nielsen, Jens Peter; Christiansen, Lasse Engbo; Angen, Øystein; Ahmed, Shahana; Folkesson, Anders; Olsen, John Elmerdahl
2017-06-15
This study describes the results of a randomized clinical trial investigating the effect of oxytetracycline treatment dose and mode of administration on the selection of antibiotic-resistant coliform bacteria in fecal samples from nursery pigs. Nursery pigs (pigs of 4 to 7 weeks of age) in five pig herds were treated with oxytetracycline for Lawsonia intracellularis -induced diarrhea. Each group was randomly allocated to one of five treatment groups: oral flock treatment with a (i) high (20 mg/kg of body weight), (ii) medium (10 mg/kg), or (iii) low (5 mg/kg) dose, (iv) oral pen-wise (small-group) treatment (10 mg/kg), and (v) individual intramuscular injection treatment (10 mg/kg). All groups were treated once a day for 5 days. In all groups, treatment caused a rise in the numbers and proportions of tetracycline-resistant coliform bacteria right after treatment, followed by a significant drop by the time that the pigs left the nursery unit. The counts and proportions of tetracycline-resistant coliforms did not vary significantly between treatment groups, except immediately after treatment, when the highest treatment dose resulted in the highest number of resistant coliforms. A control group treated with tiamulin did not show significant changes in the numbers or proportions of tetracycline-resistant coliforms. Selection for tetracycline-resistant coliforms was significantly correlated to selection for ampicillin- and sulfonamide-resistant strains but not to selection for cefotaxime-resistant strains. In conclusion, the difference in the dose of oxytetracycline and the way in which the drug was applied did not cause significantly different levels of selection of tetracycline-resistant coliform bacteria under the conditions tested. IMPORTANCE Antimicrobial resistance is a global threat to human health. Treatment of livestock with antimicrobials has a direct impact on this problem, and there is a need to improve the ways that we use antimicrobials in livestock production. We hypothesized that antibiotic resistance development following treatment of diarrhea in nursery pigs could be reduced either by lowering the dose of oxytetracycline or by replacing the commonly used practice of flock treatment with individual or small-group treatments, since this would reduce the number of pigs treated. However, the study showed no significant difference between treatment groups with respect to the number or proportion of tetracycline-resistant coliforms selected. The most important conclusion is that under practical field conditions, there will be no added value, in terms of lowering resistance development, by exchanging flock treatment for individual or small-group treatment of nursery pigs. The reason for the lack of an effect of single-animal treatment is probably that such animals share the environment with treated animals and take up resistant bacteria from the environment. Copyright © 2017 American Society for Microbiology.
Effects of effluent spray irrigation on ground water at a test site near Tarpon Springs, Florida
Brown, D.P.
1982-01-01
Secondary-treated effluent was applied to a 7.2-acre test site near Tarpon Springs, Fla., for about 1 year at an average rate of 0.06 million gallons per day and 3 years at 0.11 million gallons per day. Chemical fertilizer was applied periodically to the test site and adjacent areas. Periodic mounding of the water table occurred due to effluent irrigation, inducing radial flow from the test site. Physical, geochemical, biochemical processes effectively reduced total nitrogen concentration 90% and total phosphorous concentration more than 95% in the ground water of the surficial aquifer about 300 feet downgradient from the test site from that of the applied effluent. Downgradient, total nitrogen averaged 2.4 milligrams per liter and total phosphorus averaged 0.17 milligrams per liter. Substantial increases in total phosphorus were observed when the pH of the ground water increased. Total coliform bacteria in the ground water of the surficial aquifer were generally less than 100 colonies per 100 milliliters. Fecal coliform bacteria were generally less than 25 colonies per 100 milliliters at the test site and were not detected downgradient or near the test site. Fecal streptococcal bacteria were generally less than 100 colonies per 100 milliliters at the test site, but were detected on three occasions near the test site. (USGS)
Williams, Ashley R.; Bain, Robert E. S.; Fisher, Michael B.; Cronk, Ryan; Kelly, Emma R.; Bartram, Jamie
2015-01-01
Background Packaged water products provide an increasingly important source of water for consumption. However, recent studies raise concerns over their safety. Objectives To assess the microbial safety of packaged water, examine differences between regions, country incomes, packaged water types, and compare packaged water with other water sources. Methods We performed a systematic review and meta-analysis. Articles published in English, French, Portuguese, Spanish and Turkish, with no date restrictions were identified from online databases and two previous reviews. Studies published before April 2014 that assessed packaged water for the presence of Escherichia coli, thermotolerant or total coliforms were included provided they tested at least ten samples or brands. Results A total of 170 studies were included in the review. The majority of studies did not detect fecal indicator bacteria in packaged water (78/141). Compared to packaged water from upper-middle and high-income countries, packaged water from low and lower-middle-income countries was 4.6 (95% CI: 2.6–8.1) and 13.6 (95% CI: 6.9–26.7) times more likely to contain fecal indicator bacteria and total coliforms, respectively. Compared to all other packaged water types, water from small bottles was less likely to be contaminated with fecal indicator bacteria (OR = 0.32, 95%CI: 0.17–0.58) and total coliforms (OR = 0.10, 95%CI: 0.05, 0.22). Packaged water was less likely to contain fecal indicator bacteria (OR = 0.35, 95%CI: 0.20, 0.62) compared to other water sources used for consumption. Conclusions Policymakers and regulators should recognize the potential benefits of packaged water in providing safer water for consumption at and away from home, especially for those who are otherwise unlikely to gain access to a reliable, safe water supply in the near future. To improve the quality of packaged water products they should be integrated into regulatory and monitoring frameworks. PMID:26505745
Williams, Ashley R; Bain, Robert E S; Fisher, Michael B; Cronk, Ryan; Kelly, Emma R; Bartram, Jamie
2015-01-01
Packaged water products provide an increasingly important source of water for consumption. However, recent studies raise concerns over their safety. To assess the microbial safety of packaged water, examine differences between regions, country incomes, packaged water types, and compare packaged water with other water sources. We performed a systematic review and meta-analysis. Articles published in English, French, Portuguese, Spanish and Turkish, with no date restrictions were identified from online databases and two previous reviews. Studies published before April 2014 that assessed packaged water for the presence of Escherichia coli, thermotolerant or total coliforms were included provided they tested at least ten samples or brands. A total of 170 studies were included in the review. The majority of studies did not detect fecal indicator bacteria in packaged water (78/141). Compared to packaged water from upper-middle and high-income countries, packaged water from low and lower-middle-income countries was 4.6 (95% CI: 2.6-8.1) and 13.6 (95% CI: 6.9-26.7) times more likely to contain fecal indicator bacteria and total coliforms, respectively. Compared to all other packaged water types, water from small bottles was less likely to be contaminated with fecal indicator bacteria (OR = 0.32, 95%CI: 0.17-0.58) and total coliforms (OR = 0.10, 95%CI: 0.05, 0.22). Packaged water was less likely to contain fecal indicator bacteria (OR = 0.35, 95%CI: 0.20, 0.62) compared to other water sources used for consumption. Policymakers and regulators should recognize the potential benefits of packaged water in providing safer water for consumption at and away from home, especially for those who are otherwise unlikely to gain access to a reliable, safe water supply in the near future. To improve the quality of packaged water products they should be integrated into regulatory and monitoring frameworks.
Effect of tannins on growth performance and intestinal ecosystem in weaned piglets.
Biagia, Giacomo; Cipollini, Irene; Paulicks, Brigitte R; Roth, Franz X
2010-04-01
Tannins are natural polyphenolic compounds that can reduce digestibility of dietary protein but also display antibacterial effects. The present study investigated, in vitro and in vivo, the effect of different levels of tannins (using a chestnut wood extract containing 75% tannins) on growth performance, intestinal microbiota and wall morphology in piglets. During a 24 h in vitro caecal fermentation, the utilisation of tannins at 0.75, 1.5, 3, and 6 g/l significantly reduced total gas production and concentrations of ammonia and volatile fatty acids and increased viable counts of enterococci and coliforms. When fed to piglets at 1.13, 2.25, and 4.5 g/kg, tannins significantly improved feed efficiency and reduced caecal concentrations of ammonia, iso-butyric, and iso-valeric acid. Viable counts of lactobacilli tended to be increased by tannins in the jejunum, while bacterial caecal counts were not affected. Depth of ileal crypts tended to decrease in piglets fed tannins at 2.25 and 4.5 g/kg. The present study showed that feeding weaned piglets with a tannin-rich wood extract can result in improved feed efficiency and reduction of intestinal bacterial proteolytic reactions. The growth-enhancing effect that tannins had on enterococci and coliforms under in vitro conditions deserves further investigation.
Studies on urban drinking water quality in a tropical zone.
Mudiam, Mohana Krishna Reddy; Pathak, S P; Gopal, K; Murthy, R C
2012-01-01
Anthropogenic activities associated with industrialization, agriculture and urbanization have led to the deterioration in water quality due to various contaminants. To assess the status of urban drinking water quality, samples were collected from the piped supplies as well as groundwater sources from different localities of residential, commercial and industrial areas of Lucknow City in a tropical zone of India during pre-monsoon for estimation of coliform and faecal coliform bacteria, organochlorine pesticides (OCPs) and heavy metals. Bacterial contamination was found to be more in the samples from commercial areas than residential and industrial areas. OCPs like α,γ-hexachlorocyclohexane and 1,1 p,p-DDE {dichloro-2, 2-bis(p-chlorophenyl) ethene)} were found to be present in most of the samples from study area. The total organochlorine pesticide levels were found to be within the European Union limit (0.5 μg/L) in most of the samples. Most of the heavy metals estimated in the samples were also found to be within the permissible limits as prescribed by World Health Organization for drinking water. Thus, these observations show that contamination of drinking water in urban areas may be mainly due to municipal, industrial and agricultural activities along with improper disposal of solid waste. This is an alarm to safety of public health and aquatic environment in tropics.
Manufacture of ice cream with improved microbiological safety by using gamma irradiation
NASA Astrophysics Data System (ADS)
Lee, Ju-Woon; Kim, Hyun-Joo; Yoon, Yohan; Kim, Jae-Hun; Ham, Jun-Sang; Byun, Myung-Woo; Baek, Min; Jo, Cheorun; Shin, Myung-Gon
2009-07-01
Children suffered from leukemia want to eat delicious dishes, such as cake and ice cream. However, it is very difficult to serve these foods to immune-compromised patients without application of any adequate sanitary measures. This study was conducted to evaluate application of irradiation to frozen ready-to-eat food, ice cream. Three ice creams with flavors of vanilla, chocolate and strawberry were manufactured and gamma irradiated at the absorbed doses of 1, 3, and 5 kGy at -70 °C. Total microflora and coliform bacteria were determined, and Listeria spp., Escherichia coli and Salmonella spp. were also tested by the use of API 20E Kit. Aerobic bacteria, yeast/mold and coliforms were contaminated in the levels of 2.3 to 3.3, 2.3 to 2.7 and 1.7 to 2.4 log CFU/g, respectively. In samples irradiated at 5 kGy, the growth of any microorganisms could not be observed. Listeria spp. and E. coli were detected at non-irradiated samples, but S. spp. was not existed. D10 values of L. ivanovii and E. coli were 0.75 and 0.31 kGy, respectively, in ice cream. From these results, irradiation technology can reduce the risk by the food-borne pathogens of ice cream.