Continuous Change Detection and Classification (CCDC) of Land Cover Using All Available Landsat Data
NASA Astrophysics Data System (ADS)
Zhu, Z.; Woodcock, C. E.
2012-12-01
A new algorithm for Continuous Change Detection and Classification (CCDC) of land cover using all available Landsat data is developed. This new algorithm is capable of detecting many kinds of land cover change as new images are collected and at the same time provide land cover maps for any given time. To better identify land cover change, a two step cloud, cloud shadow, and snow masking algorithm is used for eliminating "noisy" observations. Next, a time series model that has components of seasonality, trend, and break estimates the surface reflectance and temperature. The time series model is updated continuously with newly acquired observations. Due to the high variability in spectral response for different kinds of land cover change, the CCDC algorithm uses a data-driven threshold derived from all seven Landsat bands. When the difference between observed and predicted exceeds the thresholds three consecutive times, a pixel is identified as land cover change. Land cover classification is done after change detection. Coefficients from the time series models and the Root Mean Square Error (RMSE) from model fitting are used as classification inputs for the Random Forest Classifier (RFC). We applied this new algorithm for one Landsat scene (Path 12 Row 31) that includes all of Rhode Island as well as much of Eastern Massachusetts and parts of Connecticut. A total of 532 Landsat images acquired between 1982 and 2011 were processed. During this period, 619,924 pixels were detected to change once (91% of total changed pixels) and 60,199 pixels were detected to change twice (8% of total changed pixels). The most frequent land cover change category is from mixed forest to low density residential which occupies more than 8% of total land cover change pixels.
Vaïtilingom, M; Pijnenburg, H; Gendre, F; Brignon, P
1999-12-01
A fast and quantitative method was developed to detect transgenic "Maximizer" maize "event 176" (Novartis) and "Roundup Ready" soybean (Monsanto) in food by real-time quantitative PCR. The use of the ABI Prism 7700 sequence detection system allowed the determination of the amplified product accumulation through a fluorogenic probe (TaqMan). Fluorescent dyes were chosen in such a way as to coamplify total and transgenic DNA in the same tube. Using real-time quantitative PCR, 2 pg of transgenic or total DNA per gram of starting sample was detected in 3 h after DNA extraction and the relative amounts of "Maximizer" maize and "Roundup Ready" soybean in some representative food products were quantified.
Real time in situ detection of organic nitrates in atmospheric aerosols.
Rollins, Andrew W; Smith, Jared D; Wilson, Kevin R; Cohen, Ronald C
2010-07-15
A novel instrument is described that quantifies total particle-phase organic nitrates in real time with a detection limit of 0.11 microg m(-3) min(-1), 45 ppt min(-1) (-ONO(2)). Aerosol nitrates are separated from gas-phase nitrates with a short residence time activated carbon denuder. Detection of organic molecules containing -ONO(2) subunits is accomplished using thermal dissociation coupled to laser induced fluorescence detection of NO(2). This instrument is capable of high time resolution (seconds) measurements of particle-phase organic nitrates, without interference from inorganic nitrate. Here we use it to quantify organic nitrates in secondary organic aerosol generated from high-NO(x) photooxidation of limonene, alpha-pinene, Delta-3-carene, and tridecane. In these experiments the organic nitrate moiety is observed to be 6-15% of the total SOA mass.
NASA Technical Reports Server (NTRS)
Khodadad, Christina L.; Birmele, Michele N.; Roman, Monsi; Hummerick, Mary E.; Smith, David J.; Wheeler, Raymond M.
2015-01-01
Previous research has shown that potentially destructive microorganisms and human pathogens have been detected on the International Space Station (ISS). The likelihood of introducing new microorganisms occurs with every exchange of crew or addition of equipment or supplies. Microorganisms introduced to the ISS are readily transferred between crew and subsystems (i.e. ECLSS, environmental control and life support systems). Current microbial characterization methods require enrichment of microorganisms and at least a 48-hour incubation time. This increases the microbial load while detecting only a limited number of the total microorganisms. The culture based method detects approximately 1-10% of the total organisms present and provides no identification. To identify and enumerate ISS microbes requires that samples be returned to Earth for complete analysis. Therefore, a more expedient, low-cost, in-flight method of microbial detection, identification, and enumeration is warranted. The RAZOR EX, a ruggedized, commercial off the shelf, real-time PCR field instrument was tested for its ability to detect microorganisms at low concentrations within one hour. Escherichia coli, Salmonella enterica Typhimurium, and Pseudomonas aeruginosa were detected at low levels using real-time DNA amplification. Total heterotrophic counts could also be detected using a 16S gene marker that can identify up to 98% of all bacteria. To reflect viable cells found in the samples, RNA was also detectable using a modified, single-step reverse transcription reaction.
Passive Multistatic Detection of Maritime Targets using Opportunistic Radars
2014-03-01
coordinate position for aa =1:1:length(Err_time1) Err_Total1( aa ) = max(abs(Err_time1( aa )),abs(Err_L1( aa ))+abs(Err_thetaR1( aa ))); end for aa =1...1:length(Err_time1) Err_Total1( aa ) = max(abs(Err_Total1( aa )),abs(Err_thetaR1( aa ))); end 93 %%%%%%%%%%%%%%%%%%%%% Tx 2...Err_Total2=zeros(size(Err_time2)); % Find th emax of the three source of error and use that for that % coordinate position for aa =1:1:length
Discounting the duration of bolus exposure in impedance testing underestimates acid reflux.
Vikneswaran, Namasivayam; Murray, Joseph A
2016-06-08
Combined impedance-pH testing (MII) allows for detection of reflux episodes regardless of pH. However impedance-based diagnosis of reflux may not routinely account for duration of the reflux episode. We hypothesize that impedance testing may be less sensitive than pH-testing in detecting acid reflux off therapy as a result of discounting duration of exposure. Baseline characteristics and reflux parameters of MII studies performed off-anti-secretory medications were analyzed. Studies on acid suppressive medication and those with recording times less than 20 h or low baseline impedance were excluded. A total of 73 consecutive MII studies were analyzed of which 31 MII studies had elevated acid exposure while 16 were abnormal by impedance criteria. MII testing off-therapy was more likely to be abnormal by pH criteria (percent time pH < 4) than impedance criteria (total reflux):[42 vs 22 % (p =0.02)]. Acid exposure (percent time pH < 4) identified more studies as abnormal than MII-detected acid reflux episodes [42 vs 34 % (p < 0.01)]. Mean acid clearance time (pH-detected) was significantly longer than median bolus clearance time (impedance-detected) in the total [98.7 s vs 12.6 s (p < 0.01)], upright [58.6 s vs 13.1 s (p < 0.01)], and recumbent positions [136.7 s vs 14.2 s (p < 0.01)] with the greatest difference seen in the recumbent position. The mean ratio of mean acid clearance time (pH-detected) and the median bolus clearance time (impedance-detected) was significantly higher in the recumbent position compared to the upright position [11. vs 5.3 (p = 0.01)]. Ambulatory impedance testing underestimates acid reflux compared to esophageal acid exposure by discounting the prolonged period of mucosal contact with each acid reflux episode, particularly in the recumbent position.
Waitumbi, John N; Gerlach, Jay; Afonina, Irina; Anyona, Samuel B; Koros, Joseph N; Siangla, Joram; Ankoudinova, Irina; Singhal, Mitra; Watts, Kate; Polhemus, Mark E; Vermeulen, Nicolaas M; Mahoney, Walt; Steele, Matt; Domingo, Gonzalo J
2011-07-01
To determine the malaria prevalence by microscopy, antigen detection and nucleic acid detection in a defined subpopulation in a Plasmodium falciparum-endemic region during the peak transmission season. Blood specimens were collected in a cross-sectional study involving children aged 5-10 years (n = 195) presenting with acute fever to two clinics in Western Kenya. All specimens underwent microscopy, HRP2 and aldolase antigen detection by enzyme immunoassay (EIA), parasite-specific DNA and total nucleic acid (RNA and DNA) by real-time PCR (qPCR) and reverse-transcriptase PCR (qRT-PCR). Microscopy detected 65/195 cases of malaria infection [95% confidence interval (CI) 52-78]. HRP2 and aldolase EIA had similar sensitivity levels detecting antigen in 65/195 (95% CI, 52-78) and 57/195 (95% CI, 45-70) cases. Discordants in antigen detection vs. microscopy occurred at <470 parasites/μl and <4900 parasites/μl for HRP2 and aldolase, respectively. Detection of total nucleic acid allowed a 3 log lower limit of detection than just DNA detection by real-time PCR in vitro. In clinical specimens, 114/195 (95% CI, 100-127) were qPCR positive (DNA), and 187/195 (95% CI, 179-191) were qRT-PCR positive (DNA plus RNA). The prevalence of submicroscopic malaria infection was significantly higher when detecting total nucleic acid than just DNA in this outpatient population during the high transmission season. Defining standards for submicroscopic infection will be important for control programmes, diagnostics development efforts and molecular epidemiology studies. © 2011 Blackwell Publishing Ltd.
Integrated micro-optofluidic platform for real-time detection of airborne microorganisms
NASA Astrophysics Data System (ADS)
Choi, Jeongan; Kang, Miran; Jung, Jae Hee
2015-11-01
We demonstrate an integrated micro-optofluidic platform for real-time, continuous detection and quantification of airborne microorganisms. Measurements of the fluorescence and light scattering from single particles in a microfluidic channel are used to determine the total particle number concentration and the microorganism number concentration in real-time. The system performance is examined by evaluating standard particle measurements with various sample flow rates and the ratios of fluorescent to non-fluorescent particles. To apply this method to real-time detection of airborne microorganisms, airborne Escherichia coli, Bacillus subtilis, and Staphylococcus epidermidis cells were introduced into the micro-optofluidic platform via bioaerosol generation, and a liquid-type particle collection setup was used. We demonstrate successful discrimination of SYTO82-dyed fluorescent bacterial cells from other residue particles in a continuous and real-time manner. In comparison with traditional microscopy cell counting and colony culture methods, this micro-optofluidic platform is not only more accurate in terms of the detection efficiency for airborne microorganisms but it also provides additional information on the total particle number concentration.
Integrated micro-optofluidic platform for real-time detection of airborne microorganisms
Choi, Jeongan; Kang, Miran; Jung, Jae Hee
2015-01-01
We demonstrate an integrated micro-optofluidic platform for real-time, continuous detection and quantification of airborne microorganisms. Measurements of the fluorescence and light scattering from single particles in a microfluidic channel are used to determine the total particle number concentration and the microorganism number concentration in real-time. The system performance is examined by evaluating standard particle measurements with various sample flow rates and the ratios of fluorescent to non-fluorescent particles. To apply this method to real-time detection of airborne microorganisms, airborne Escherichia coli, Bacillus subtilis, and Staphylococcus epidermidis cells were introduced into the micro-optofluidic platform via bioaerosol generation, and a liquid-type particle collection setup was used. We demonstrate successful discrimination of SYTO82-dyed fluorescent bacterial cells from other residue particles in a continuous and real-time manner. In comparison with traditional microscopy cell counting and colony culture methods, this micro-optofluidic platform is not only more accurate in terms of the detection efficiency for airborne microorganisms but it also provides additional information on the total particle number concentration. PMID:26522006
He, Yu-min; Lu, Ke-ming; Yuan, Ding; Zhang, Chang-cheng
2008-11-01
To explore the optimum extraction and purification condition of the total saponins in the root of Panax japonicus (RPJ), and establish its quality control methods. Designed L16 (4(5)) orthogonal test with the extraction rate of total saponins as index, to determine the rational extraction process, and the techniques of water-saturated n-butanol extraction and acetone precipitation were applied to purify the alcohol extract of RPJ. Total saponins were detected by spectrophotometry and its triterpenoidal sapogenin oleanolic acid detected by HPLC. The optimum conditions of total saponins from RPJ was as follows: the material was pulverized, dipped in 60% ethanol aqueous solution as extract solvent at 10 times of volume, and refluxed 3 times for 3 h each time. Extractant of water-saturated n-butanol with extraction times of 3 and precipitant of acetone with precipitation amount of 4-5 times were included in the purification process, which would obtain the quality products. The content of total saponins could reach to 83.48%, and oleanolic acid to 38.30%. The optimized preparative technology is stable, convenient and practical. The extract rate of RPJ was high and steady with this technology, which provided new evidence for industrializing production of the plant and developing new drug.
First Detected Arrival of a Quantum Walker on an Infinite Line
NASA Astrophysics Data System (ADS)
Thiel, Felix; Barkai, Eli; Kessler, David A.
2018-01-01
The first detection of a quantum particle on a graph is shown to depend sensitively on the distance ξ between the detector and initial location of the particle, and on the sampling time τ . Here, we use the recently introduced quantum renewal equation to investigate the statistics of first detection on an infinite line, using a tight-binding lattice Hamiltonian with nearest-neighbor hops. Universal features of the first detection probability are uncovered and simple limiting cases are analyzed. These include the large ξ limit, the small τ limit, and the power law decay with the attempt number of the detection probability over which quantum oscillations are superimposed. For large ξ the first detection probability assumes a scaling form and when the sampling time is equal to the inverse of the energy band width nonanalytical behaviors arise, accompanied by a transition in the statistics. The maximum total detection probability is found to occur for τ close to this transition point. When the initial location of the particle is far from the detection node we find that the total detection probability attains a finite value that is distance independent.
NASA Technical Reports Server (NTRS)
Zeitlin, Nancy; Mullenix, Pamela; Wheeler, Raymond M.; Ruby, Anna Maria
2015-01-01
Previous research has shown that potential human pathogens have been detected on the International Space Station (ISS). New microorganisms are introduced with every exchange of crew and cargo. Microorganisms introduced to the ISS are readily transferred between crew and subsystems (i.e., ECLSS, environmental control and life support systems). Current microbial characterization methods require a culture-based enrichment of microorganisms and at least a 48-hour incubation time. This increases the microbial load while detecting only a limited number of microorganisms. The culture-based method detects approximately 1-10% of the total organisms present and provides no identification. To identify and enumerate ISS samples requires that the microbes be returned to Earth for complete analysis. Therefore, a more expedient, low-cost, inflight method of microbial detection, identification, and enumeration is needed. The RAZOR EX, a ruggedized, commercial off the shelf, real-time PCR field instrument was tested for its ability to detect microorganisms at low concentrations within one hour. Escherichia coli, Salmonella enterica Typhimurium, and Pseudomonas aeruginosa were detected at low levels using real-time DNA amplification. Total heterotrophic counts could also be detected using a 16S gene marker that can identify up to 98% of all bacteria. To reflect viable cells found in the samples, RNA was also detectable using a modified, single-step reverse transcription reaction.
[Application of recombinase polymerase amplification in the detection of Pseudomonas aeruginosa].
Jin, X J; Gong, Y L; Yang, L; Mo, B H; Peng, Y Z; He, P; Zhao, J N; Li, X L
2018-04-20
Objective: To establish an optimized method of recombinase polymerase amplification (RPA) to rapidly detect Pseudomonas aeruginosa in clinic. Methods: (1) The DNA templates of one standard Pseudomonas aeruginosa strain was extracted and detected by polymerase chain reaction (PCR), real-time fluorescence quantitative PCR and RPA. Time of sample loading, time of amplification, and time of detection of the three methods were recorded. (2) One standard Pseudomonas aeruginosa strain was diluted in 7 concentrations of 1×10(7,) 1×10(6,) 1×10(5,) 1×10(4,) 1×10(3,) 1×10(2,) and 1×10(1) colony forming unit (CFU)/mL after recovery and cultivation. The DNA templates of Pseudomonas aeruginosa and negative control strain Pseudomonas putida were extracted and detected by PCR, real-time fluorescence quantitative PCR, and RPA separately. The sensitivity of the three methods in detecting Pseudomonas aeruginosa was analyzed. (3) The DNA templates of one standard Pseudomonas aeruginosa strain and four negative control strains ( Staphylococcus aureus, Acinetobacter baumanii, Candida albicans, and Pseudomonas putida ) were extracted separately, and then they were detected by PCR, real-time fluorescence quantitative PCR, and RPA. The specificity of the three methods in detecting Pseudomonas aeruginosa was analyzed. (4) The DNA templates of 28 clinical strains of Pseudomonas aeruginosa preserved in glycerin, 1 clinical strain of which was taken by cotton swab, and negative control strain Pseudomonas putida were extracted separately, and then they were detected by RPA. Positive amplification signals of the clinical strains were observed, and the detection rate was calculated. All experiments were repeated for 3 times. Sensitivity results were analyzed by GraphPad Prism 5.01 statistical software. Results: (1) The loading time of RPA, PCR, and real-time fluorescence quantitative PCR for detecting Pseudomonas aeruginosa were all 20 minutes. In PCR, time of amplification was 98 minutes, time of gel detection was 20 minutes, and the total time was 138 minutes. In real-time fluorescence quantitative PCR, amplification and detection could be completed simultaneously, which took 90 minutes, and the total time was 110 minutes. In RPA, amplification and detection could also be completed simultaneously, which took 15 minutes, and the total time was 35 minutes. (2) Pseudomonas putida did not show positive amplification signals or gel positive results in any of the three detection methods. The detection limit of Pseudomonas aeruginosa in real-time fluorescence quantitative PCR and PCR was 1×10(1) CFU/mL, and that of Pseudomonas aeruginosa in RPA was 1×10(2) CFU/mL. In RPA and real-time fluorescence quantitative PCR, the higher the concentration of Pseudomonas aeruginosa, the shorter threshold time and smaller the number of cycles, namely shorter time for detecting the positive amplified signal. In real-time fluorescence quantitative PCR, all positive amplification signal could be detected when the concentration of Pseudomonas aeruginosa was 1×10(1)-1×10(7) CFU/mL. In RPA, the detection rate of positive amplification signal was 0 when the concentration of Pseudomonas aeruginosa was 1×10(1) CFU/mL, while the detection rate of positive amplification signal was 67% when the concentration of Pseudomonas aeruginosa was 1×10(2) CFU/mL, and the detection rate of positive amplification signal was 100% when the concentration of Pseudomonas aeruginosa was 1×10(3)-1×10(7) CFU/mL. (3) In RPA, PCR, and real-time fluorescence quantitative PCR, Pseudomonas aeruginosa showed positive amplification signals and gel positive results, but there were no positive amplification signals or gel positive results in four negative control strains of Acinetobacter baumannii, Staphylococcus aureus, Candida albicans, and Pseudomonas putida . (4) In RPA, 28 clinical strains of Pseudomonas aeruginosa preserved in glycerin and 1 clinical strain of Pseudomonas aeruginosa taken by cotton swab showed positive amplification signals, while Pseudomonas putida did not show positive amplification signal. The detection rate of positive amplification signal of 29 clinical strains of Pseudomonas aeruginosa in RPA was 100%. Conclusions: The established optimized RPA technology for fast detection of Pseudomonas aeruginosa requires shorter time, with high sensitivity and specificity. It was of great value in fast detection of Pseudomonas aeruginosa infection in clinic.
Total ozone trend significance from space time variability of daily Dobson data
NASA Technical Reports Server (NTRS)
Wilcox, R. W.
1981-01-01
Estimates of standard errors of total ozone time and area means, as derived from ozone's natural temporal and spatial variability and autocorrelation in middle latitudes determined from daily Dobson data are presented. Assessing the significance of apparent total ozone trends is equivalent to assessing the standard error of the means. Standard errors of time averages depend on the temporal variability and correlation of the averaged parameter. Trend detectability is discussed, both for the present network and for satellite measurements.
Hata, S; Hata, H; Miyasawa-Hori, H; Kudo, A; Mayanagi, H
2006-02-01
To detect quantitatively the total bacteria and Streptococcus mutans in dental plaque by real-time PCR with prbac, Sm and GTF-B primers, and to compare their presence with the prevalence of dental caries in Japanese preschool children. Human dental plaque samples were collected from the labial surfaces of the upper primary central incisors of 107 children. The dental status was recorded as dft by WHO caries diagnostic criteria. Positive dt and dft scores by the Sm or GTF-B primer were significantly higher than negative scores (P < 0.01). The proportions of Strep. mutans to the total bacteria from sound, and sound and/or filled upper primary incisors were significantly lower than those from decayed or filled, and decayed incisors, respectively (P < 0.01). The ratios of Strep. mutans to total bacteria in plaque detected by real-time PCR with Sm and GTF-B primers were closely associated with the prevalence of dental caries in Japanese preschool children. These assays may be useful for the assessment of an individual's risk of dental caries.
Worakhunpiset, S; Tharnpoophasiam, P
2009-07-01
Although multiplex PCR amplification condition for simultaneous detection of total coliform bacteria, Escherichia coli and Clostridium perfringens in water sample has been developed, results with high sensitivity are obtained when amplifying purified DNA, but the sensitivity is low when applied to spiked water samples. An enrichment broth culture prior PCR analysis increases sensitivity of the test but the specific nature of enrichment broth can affect the PCR results. Three enrichment broths, lactose broth, reinforced clostridial medium and fluid thioglycollate broth, were compared for their influence on sensitivity and on time required with multiplex PCR assay. Fluid thioglycollate broth was the most effective with shortest enrichment time and lowest detection limit.
NASA Technical Reports Server (NTRS)
Khodadad, Christina L.; Birmele, Michele N.; Roman, Monsi; Hummerick, Mary E.; Smith, David J.; Wheeler, Raymond M.
2015-01-01
Previous research has shown that microorganisms and potential human pathogens have been detected on the International Space Station (ISS). The potential to introduce new microorganisms occurs with every exchange of crew or addition of equipment or supplies. Previous research has shown that microorganisms introduced to the ISS are readily transferred between crew and subsystems and back (i.e. ECLSS, environmental control and life support systems). Current microbial characterization methods require enrichment of microorganisms and a 48-hour incubation time. This increases the microbial load while detecting a limited number of microorganisms. The culture based method detects approximately 1-10% of the total organisms present and provides no identification, To identify and enumerate ISS samples requires that samples to be returned to Earth for complete analysis. Therefore, a more expedient, low-cost, in-flight method of microbial detection, identification, and enumeration is warranted. The RAZOR EX, a ruggedized, commercial off the shelf, real-time PCR field instrument was tested for its ability to detect microorganism at low concentrations within one hour. Escherichia coli, Salmonella enterica Typhimurium, and Pseudomonas aeruginosa were detected at low levels using real-time DNA amplification. Total heterotrophic counts could also be detected using a 16S gene marker that can identify up to 98% of all bacteria. To reflect viable cells found in the samples, RNA was also detectable using a modified, single-step reverse transcription reaction.
Variation of a Lightning NOx Indicator for National Climate Assessment
NASA Technical Reports Server (NTRS)
Koshak, W. J.; Vant-Hull, B.; McCaul, E. W.; Peterson, H. S.
2014-01-01
In support of the National Climate Assessment (NCA) program, satellite Lightning Imaging Sensor (LIS) data is used to estimate lightning nitrogen oxides (LNOx) production over the southern portion of the conterminous US. The total energy of each flash is estimated by analyzing the LIS optical event data associated with each flash (i.e., event radiance, event footprint area, and derivable event range). The LIS detects an extremely small fraction of the total flash energy; this fraction is assumed to be constant apart from the variability associated with the flash optical energy detected across the narrow (0.909 nm) LIS band. The estimate of total energy from each flash is converted to moles of LNOx production by assuming a chemical yield of 10(17) molecules Joule(-1). The LIS-inferred variable LNOx production from each flash is summed to obtain total LNOx production, and then appropriately enhanced to account for LIS detection efficiency and LIS view time. Annual geographical plots and time series of LNOx production are provided for a 16 year period (1998-2013).
APD Response Time Measurements for Future TOF-E Systems
NASA Astrophysics Data System (ADS)
Starkey, M. J.; Ogasawara, K.; Dayeh, M. A.; Desai, M. I.
2017-12-01
In space physics, the ability to detect ions is crucial to understanding plasma distributions in the solar wind. This usually typically requires the determination of the particle's mass, charge, and total energy. Current ion detection schemes are implemented in three sequential parts; an electrostatic analyzer for energy per charge (E/Q) measurements, a time-of-flight (TOF) for mass per charge (M/Q) measurements, and a solid-state detector (SSD) for total energy (E) measurements. Recent work has suggested the use of avalanche photodiode detectors (APD) for a simultaneous TOF and total energy (TOF-E) measurement system, which would replace traditional SSDs, simplify design, and reduce costs. Although TOF based ion spectrometry typically requires timing resolution of <1ns, the timing profile for ion detection by APDs is not well understood. In this study we examine the timing profile of 3 different APDs for ion measurements over a suprathermal energy range of 50-300 keV. The three APDs differ by their doping type (N or P) and their detector thickness (30 μm or 150 μm). We find that APD P30, which is P doped and 30μm thick, provides the fastest rise times of the three APDs. Furthermore, these rise times are species independent and less than 1 ns. Our study shows that APDs are capable of sub-nanosecond response times for low energy ions and thus supports the future use of APDs in replacing SSDs in some TOF-E systems.
Groß, Andrea; Beulertz, Gregor; Marr, Isabella; Kubinski, David J.; Visser, Jaco H.; Moos, Ralf
2012-01-01
The accumulating-type (or integrating-type) NOx sensor principle offers two operation modes to measure low levels of NOx: The direct signal gives the total amount dosed over a time interval and its derivative the instantaneous concentration. With a linear sensor response, no baseline drift, and both response times and recovery times in the range of the gas exchange time of the test bench (5 to 7 s), the integrating sensor is well suited to reliably detect low levels of NOx. Experimental results are presented demonstrating the sensor’s integrating properties for the total amount detection and its sensitivity to both NO and to NO2. We also show the correlation between the derivative of the sensor signal and the known gas concentration. The long-term detection of NOx in the sub-ppm range (e.g., for air quality measurements) is discussed. Additionally, a self-adaption of the measurement range taking advantage of the temperature dependency of the sensitivity is addressed. PMID:22736980
Driver fatigue detection based on eye state.
Lin, Lizong; Huang, Chao; Ni, Xiaopeng; Wang, Jiawen; Zhang, Hao; Li, Xiao; Qian, Zhiqin
2015-01-01
Nowadays, more and more traffic accidents occur because of driver fatigue. In order to reduce and prevent it, in this study, a calculation method using PERCLOS (percentage of eye closure time) parameter characteristics based on machine vision was developed. It determined whether a driver's eyes were in a fatigue state according to the PERCLOS value. The overall workflow solutions included face detection and tracking, detection and location of the human eye, human eye tracking, eye state recognition, and driver fatigue testing. The key aspects of the detection system incorporated the detection and location of human eyes and driver fatigue testing. The simplified method of measuring the PERCLOS value of the driver was to calculate the ratio of the eyes being open and closed with the total number of frames for a given period. If the eyes were closed more than the set threshold in the total number of frames, the system would alert the driver. Through many experiments, it was shown that besides the simple detection algorithm, the rapid computing speed, and the high detection and recognition accuracies of the system, the system was demonstrated to be in accord with the real-time requirements of a driver fatigue detection system.
Tennessee Valley Total and Cloud-to-Ground Lightning Climatology Comparison
NASA Technical Reports Server (NTRS)
Buechler, Dennis; Blakeslee, R. J.; Hall, J. M.; McCaul, E. W.
2008-01-01
The North Alabama Lightning Mapping Array (NALMA) has been in operation since 2001 and consists often VHF receivers deployed across northern Alabama. The NALMA locates sources of impulsive VHF radio signals from total lightning by accurately measuring the time that the signals arrive at the different receiving stations. The sources detected are then clustered into flashes by applying spatially and temporally constraints. This study examines the total lightning climatology of the region derived from NALMA and compares it to the cloud-to-ground (CG) climatology derived from the National Lightning Detection Network (NLDN) The presentation compares the total and CG lightning trends for monthly, daily, and hourly periods.
Duan, Bin-Wei; Lu, Shi-Chun; Lai, Wei; Liu, Xue-En; Liu, Yuan
2015-01-01
To investigate the levels of hepatitis B virus total DNA (HBV DNA) and covalently closed circular (ccc) DNA in liver transplant recipients who received hepatitis B vaccination, including responders and non-responders, following liver transplantation due to hepatitis B-related diseases and to investigate the efficacy of hepatitis B immune reconstitution against HBV reinfection. Twenty responders and 34 non-responders were enrolled in the present study. The levels of HBV total DNA and ccc DNA in peripheral blood mononuclear cells (PBMCs) and the liver and plasma were detected by real-time polymerase chain reaction (PCR). Fifty-three blood samples and 38 liver allograft tissues were acquired. For the responders, the mean serum titer for anti-HBs (antibodies against hepatitis B surface antigen) was 289 (46.64-1000) IU/ml. Also for the responders, HBV total DNA was detected in PBMCs for one recipient and in the liver for another recipient, but ccc DNA was not detected in either of those 2 recipients. For the non-responders, HBV total DNA was detected in PBMCS for 2 recipients, neither of whom had ccc DNA. Also for the non-responders, HBV total DNA was detected in the livers of 3 recipients, 2 of whom also had ccc DNA. All responders had discontinued hepatitis B immunoglobulin (HBIG), and 13 responders had discontinued antiviral agents. One responder experienced HBV recurrence during the follow-up period. For the majority of liver transplant recipients, no HBV total DNA or ccc DNA was detected in the blood or liver. The lack of HBV total DNA and ccc DNA both in PBMCs and the liver in liver transplant recipients who received hepatitis B vaccination to prevent HBV reinfection should be a prerequisite for the withdrawal of HBIG and/or antiviral agents.
Detection of total knee prostheses at airport security checkpoints.
Naziri, Qais; Johnson, Aaron J; Hooper, Hasan A; Sana, Said H; Mont, Michael A
2012-06-01
Airport security screening measures have changed substantially during the past decade, but few reports have examined how this affects patients who have undergone knee arthroplasties. The purpose of this study was to characterize the efficacy of airport metal detection of total knee prostheses, the delays faced, any inconvenience this may have caused, and the role of implant identification cards. Ninety-seven total knee arthroplasty recipients reported passing through an airport metal detector, with 70 triggering the alarm a mean of 3 times (range, 1-36). The presence of a single-knee prosthesis triggered airport security alarms more than 83% of the time and increased patient inconvenience. Patients should be informed about this chance and be prepared to present documentation of their prosthesis. Copyright © 2012 Elsevier Inc. All rights reserved.
Anthony Johnson, A M; Dasgupta, I; Sai Gopal, D V R
2014-07-01
Citrus yellow mosaic badnavirus (CMBV) is an important pathogen in southern India spread by infected citrus propagules. One of the measures to arrest the spread of CMBV is to develop methods to screen and certify citrus propagules as CMBV-free. The methods loop-mediated isothermal amplification (LAMP) and SYBR green real-time PCR (SGRTPCR) have been developed for the efficient detection of CMBV in citrus propagules. This paper compares the sensitivities of LAMP and SGRTPCR with polymerase chain reaction (PCR) for the detection of CMBV. Whereas PCR and LAMP were able to detect CMBV from a minimum of 10 ng of total DNA of infected leaf samples, SGRTPCR could detect the same from 1 ng of total DNA. Using SGRTPCR, the viral titres were estimated to be the highest in rough lemon and lowest in Nagpur Mandarin of the five naturally infected citrus species tested. The results will help in designing suitable strategies for the sensitive detection of CMBV from citrus propagules. Copyright © 2014 Elsevier B.V. All rights reserved.
Firefly Algorithm in detection of TEC seismo-ionospheric anomalies
NASA Astrophysics Data System (ADS)
Akhoondzadeh, Mehdi
2015-07-01
Anomaly detection in time series of different earthquake precursors is an essential introduction to create an early warning system with an allowable uncertainty. Since these time series are more often non linear, complex and massive, therefore the applied predictor method should be able to detect the discord patterns from a large data in a short time. This study acknowledges Firefly Algorithm (FA) as a simple and robust predictor to detect the TEC (Total Electron Content) seismo-ionospheric anomalies around the time of the some powerful earthquakes including Chile (27 February 2010), Varzeghan (11 August 2012) and Saravan (16 April 2013). Outstanding anomalies were observed 7 and 5 days before the Chile and Varzeghan earthquakes, respectively and also 3 and 8 days prior to the Saravan earthquake.
Wu, Chun-Yu; Lin, Feng-Sheng; Wang, Yi-Chia; Chou, Wei-Han; Lin, Wen-Ying; Sun, Wei-Zen; Lin, Chih-Peng
2015-01-01
The role of ultrasound examination in detection of postprocedure complications from totally implantable venous access devices (TIVAD) placement is still uncertain. In a cohort of 665 cancer outpatients, we assessed a quick ultrasound examination protocol in early detection of mechanical complications of catheterization. Immediately after TIVAD placement, an ultrasound examination and chest radiography were performed to detect hemothorax, pneumothorax, and catheter malposition. The two methods were compared. Of the 668 catheters inserted, 628 were placed into axillary veins and 40 into internal jugular veins. The ultrasound examination took 2.5 ± 1.1 min. No hemothorax was detected, and neither pneumothorax nor catheter malposition was evident among the 40 internal jugular vein cannulations. Ultrasound and chest radiography examinations of the 628 axillary vein cannulations detected five and four instances of pneumothorax, respectively. Ultrasound detected all six catheter malpositions into the internal jugular vein. However, ultrasound failed to detect two out of three malpositions in the contralateral brachiocephalic vein and one kinking inside the superior vena cava. Without revision surgery, the operating time was 34.1 ± 15.6 min. With revision surgery, the operating time was shorter when ultrasound detected catheter malposition than when chest radiography was used (96.8 ± 12.9 vs. 188.8 ± 10.3 min, p < 0.001). Postprocedure ultrasound examination is a quick and sensitive method to detect TIVAD-related pneumothorax. It also precisely detects catheter malposition to internal jugular vein thus reduces time needed for revision surgery while chest radiography remains necessary to confirm catheter final position.
Schlossberg, Scott; Chase, Michael J; Griffin, Curtice R
2016-01-01
Accurate counts of animals are critical for prioritizing conservation efforts. Past research, however, suggests that observers on aerial surveys may fail to detect all individuals of the target species present in the survey area. Such errors could bias population estimates low and confound trend estimation. We used two approaches to assess the accuracy of aerial surveys for African savanna elephants (Loxodonta africana) in northern Botswana. First, we used double-observer sampling, in which two observers make observations on the same herds, to estimate detectability of elephants and determine what variables affect it. Second, we compared total counts, a complete survey of the entire study area, against sample counts, in which only a portion of the study area is sampled. Total counts are often considered a complete census, so comparing total counts against sample counts can help to determine if sample counts are underestimating elephant numbers. We estimated that observers detected only 76% ± SE of 2% of elephant herds and 87 ± 1% of individual elephants present in survey strips. Detectability increased strongly with elephant herd size. Out of the four observers used in total, one observer had a lower detection probability than the other three, and detectability was higher in the rear row of seats than the front. The habitat immediately adjacent to animals also affected detectability, with detection more likely in more open habitats. Total counts were not statistically distinguishable from sample counts. Because, however, the double-observer samples revealed that observers missed 13% of elephants, we conclude that total counts may be undercounting elephants as well. These results suggest that elephant population estimates from both sample and total counts are biased low. Because factors such as observer and habitat affected detectability of elephants, comparisons of elephant populations across time or space may be confounded. We encourage survey teams to incorporate detectability analysis in all aerial surveys for mammals.
Schlossberg, Scott; Chase, Michael J.; Griffin, Curtice R.
2016-01-01
Accurate counts of animals are critical for prioritizing conservation efforts. Past research, however, suggests that observers on aerial surveys may fail to detect all individuals of the target species present in the survey area. Such errors could bias population estimates low and confound trend estimation. We used two approaches to assess the accuracy of aerial surveys for African savanna elephants (Loxodonta africana) in northern Botswana. First, we used double-observer sampling, in which two observers make observations on the same herds, to estimate detectability of elephants and determine what variables affect it. Second, we compared total counts, a complete survey of the entire study area, against sample counts, in which only a portion of the study area is sampled. Total counts are often considered a complete census, so comparing total counts against sample counts can help to determine if sample counts are underestimating elephant numbers. We estimated that observers detected only 76% ± SE of 2% of elephant herds and 87 ± 1% of individual elephants present in survey strips. Detectability increased strongly with elephant herd size. Out of the four observers used in total, one observer had a lower detection probability than the other three, and detectability was higher in the rear row of seats than the front. The habitat immediately adjacent to animals also affected detectability, with detection more likely in more open habitats. Total counts were not statistically distinguishable from sample counts. Because, however, the double-observer samples revealed that observers missed 13% of elephants, we conclude that total counts may be undercounting elephants as well. These results suggest that elephant population estimates from both sample and total counts are biased low. Because factors such as observer and habitat affected detectability of elephants, comparisons of elephant populations across time or space may be confounded. We encourage survey teams to incorporate detectability analysis in all aerial surveys for mammals. PMID:27755570
Clinical Perspective of 3D Total Body Photography for Early Detection and Screening of Melanoma.
Rayner, Jenna E; Laino, Antonia M; Nufer, Kaitlin L; Adams, Laura; Raphael, Anthony P; Menzies, Scott W; Soyer, H Peter
2018-01-01
Melanoma incidence continues to increase across many populations globally and there is significant mortality associated with advanced disease. However, if detected early, patients have a very promising prognosis. The methods that have been utilized for early detection include clinician and patient skin examinations, dermoscopy (static and sequential imaging), and total body photography via 2D imaging. Total body photography has recently witnessed an evolution from 2D imaging with the ability to now create a 3D representation of the patient linked with dermoscopy images of individual lesions. 3D total body photography is a particularly beneficial screening tool for patients at high risk due to their personal or family history or those with multiple dysplastic naevi-the latter can make monitoring especially difficult without the assistance of technology. In this perspective, we discuss clinical examples utilizing 3D total body photography, associated advantages and limitations, and future directions of the technology. The optimal system for melanoma screening should improve diagnostic accuracy, be time and cost efficient, and accessible to patients across all demographic and socioeconomic groups. 3D total body photography has the potential to address these criteria and, most importantly, optimize crucial early detection.
Rapid and efficient detection of single chromophore molecules in aqueous solution
NASA Astrophysics Data System (ADS)
Li, Li-Qiang; Davis, Lloyd M.
1995-06-01
The first experiments on the detection of single fluorescent molecules in a flowing stream of an aqueous solution with high total efficiency are reported. A capillary injection system for sample delivery causes all the dye molecules to pass in a diffusion-broadened stream within a fast-moving sheath flow, through the center of the tightly focused laser excitation beam. Single-molecule detection with a transit time of approximately 1 ms is accomplished with a high-quantum-efficiency single-photon avalanche diode and a low dead-time time-gating circuit for discrimination of Raman-scattered light from the solvent.
First photon detection in time-resolved transillumination imaging: a theoretical evaluation.
Behin-Ain, S; van Doorn, T; Patterson, J R
2004-09-07
First photon detection, as a special case of time-resolved transillumination imaging, is studied through the derivation of the temporal probability density function (pdf) for the first arriving photon. The pdf for different laser intensities, media and second and later arriving photons were generated. The arrival time of the first detected photon reduced as the laser power increased and also when the scattering and absorption coefficients decreased. The pdf for an imbedded totally absorbing 3 mm inhomogeneity may be distinguished from the pdf of a homogeneous turbid medium similar to that of human breast in dimensions and optical properties.
Pizzi, Laura T; Waisbourd, Michael; Hark, Lisa; Sembhi, Harjeet; Lee, Paul; Crews, John E; Saaddine, Jinan B; Steele, Deon; Katz, L Jay
2018-02-01
Glaucoma is the foremost cause of irreversible blindness, and more than 50% of cases remain undiagnosed. Our objective was to report the costs of a glaucoma detection programme operationalised through Philadelphia community centres. The analysis was performed using a healthcare system perspective in 2013 US dollars. Costs of examination and educational workshops were captured. Measures were total programme costs, cost/case of glaucoma detected and cost/case of any ocular disease detected (including glaucoma). Diagnoses are reported at the individual level (therefore representing a diagnosis made in one or both eyes). Staff time was captured during site visits to 15 of 43 sites and included time to deliver examinations and workshops, supervision, training and travel. Staff time was converted to costs by applying wage and fringe benefit costs from the US Bureau of Labor Statistics. Non-staff costs (equipment and mileage) were collected using study logs. Participants with previously diagnosed glaucoma were excluded. 1649 participants were examined. Mean total per-participant examination time was 56 min (SD 4). Mean total examination cost/participant was $139. The cost/case of glaucoma newly identified (open-angle glaucoma, angle-closure glaucoma, glaucoma suspect, or primary angle closure) was $420 and cost/case for any ocular disease identified was $273. Glaucoma examinations delivered through this programme provided significant health benefit to hard-to-reach communities. On a per-person basis, examinations were fairly low cost, though opportunities exist to improve efficiency. Findings serve as an important benchmark for planning future community-based glaucoma examination programmes. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Nordstrom, Jessica L.; Vickery, Michael C. L.; Blackstone, George M.; Murray, Shelley L.; DePaola, Angelo
2007-01-01
Vibrio parahaemolyticus is an estuarine bacterium that is the leading cause of shellfish-associated cases of bacterial gastroenteritis in the United States. Our laboratory developed a real-time multiplex PCR assay for the simultaneous detection of the thermolabile hemolysin (tlh), thermostable direct hemolysin (tdh), and thermostable-related hemolysin (trh) genes of V. parahaemolyticus. The tlh gene is a species-specific marker, while the tdh and trh genes are pathogenicity markers. An internal amplification control (IAC) was incorporated to ensure PCR integrity and eliminate false-negative reporting. The assay was tested for specificity against >150 strains representing eight bacterial species. Only V. parahaemolyticus strains possessing the appropriate target genes generated a fluorescent signal, except for a late tdh signal generated by three strains of V. hollisae. The multiplex assay detected <10 CFU/reaction of pathogenic V. parahaemolyticus in the presence of >104 CFU/reaction of total V. parahaemolyticus bacteria. The real-time PCR assay was utilized with a most-probable-number format, and its results were compared to standard V. parahaemolyticus isolation methodology during an environmental survey of Alaskan oysters. The IAC was occasionally inhibited by the oyster matrix, and this usually corresponded to negative results for V. parahaemolyticus targets. V. parahaemolyticus tlh, tdh, and trh were detected in 44, 44, and 52% of the oyster samples, respectively. V. parahaemolyticus was isolated from 33% of the samples, and tdh+ and trh+ strains were isolated from 19 and 26%, respectively. These results demonstrate the utility of the real-time PCR assay in environmental surveys and its possible application to outbreak investigations for the detection of total and pathogenic V. parahaemolyticus. PMID:17644647
Portable evanescent wave fiber biosensor for highly sensitive detection of Shigella
NASA Astrophysics Data System (ADS)
Xiao, Rui; Rong, Zhen; Long, Feng; Liu, Qiqi
2014-11-01
A portable evanescent wave fiber biosensor was developed to achieve the rapid and highly sensitive detection of Shigella. In this study, a DNA probe was covalently immobilized onto fiber-optic biosensors that can hybridize with a fluorescently labeled complementary DNA. The sensitivity of detection for synthesized oligonucleotides can reach 10-10 M. The surface of the sensor can be regenerated with 0.5% sodium dodecyl sulfate solution (pH 1.9) for over 30 times without significant deterioration of performance. The total analysis time for a single sample, including the time for measurement and surface regeneration, was less than 6 min. We employed real-time polymerase chain reaction (PCR) and compared the results of both methods to investigate the actual Shigella DNA detection capability of the fiber-optic biosensor. The fiber-optic biosensor could detect as low as 102 colony-forming unit/mL Shigella. This finding was comparable with that by real-time PCR, which suggests that this method is a potential alternative to existing detection methods.
Salerni, Gabriel; Carrera, Cristina; Lovatto, Louise; Puig-Butille, Joan Anton; Badenas, Celia; Plana, Estel; Puig, Susana; Malvehy, Josep
2011-01-01
Background Early detection of melanoma is the best way to improve prognosis. Digital follow up (DFU) programs of high-risk populations could be an efficient strategy for detecting early melanomas with low morbidity. Objective to report the added value of the use of the “two-step method” (digital total-body photography and digital dermoscopy) Methods Analysis of the surveillance of 618 high-risk melanoma patients included in our DFU-program from 1999 to 2008. Results A total of 11396 lesions were monitored (mean 18.44 per patient) during a median follow-up of 96 months (median 10 visits per patient). 1152 lesions, 1.86 per patient, were excised. Almost 70% (798) were lesions previously registered at least twice, while 356 (30%) were detected and removed in the same visit. During follow-up, 98 melanomas (8.5% of excised lesions) were diagnosed in 78 patients (12.6%). 53 melanomas were in situ (53.3%), while invasive (45) showed a Breslow index of less than 1 mm (median 0.5 mm) and none was ulcerated. Limitations Since there are no control groups we cannot convey if the combined use of total-body photography and digital dermoscopy is more beneficial than these techniques used separately. Conclusion DFU with Total-Body Photography and Dermoscopy in a selected high-risk population demonstrated the early detection of melanomas with a low rate of excisions. Long-term follow-up is required to allow the detection of slow growing melanomas. Based on our 10-year experience, melanomas can be diagnosed at any time, suggesting that in high-risk population, DFU should be maintained with time. PMID:21683472
[Rapid identification of meningitis due to bacterial pathogens].
Ubukata, Kimiko
2013-01-01
We constructed a new real-time PCR method to detect causative pathogens in cerebrospinal fluid (CSF) from patient due to bacterial meningitis. The eight pathogens targeted in the PCR are Streptococcus pneumoniae, Haemophilus influenzae, Streptococcus agalactiae, Staphylococcus aurues, Neisseria meningitides, Listeria monocytogenes, Esherichia coli, and Mycoplasma pneumoniae. The total time from DNA extraction from CSF to PCR analysis was 1.5 hour. The pathogens were detected in 72% of the CSF samples (n=115) by real-time PCR, but in only 48% by culture, although the microorganisms were completely concordant. The detection rate of pathogens with PCR was significantly better than that with cultures in patients with antibiotic administration.In conclusion, detection with real-time PCR is useful for rapidly identifying the causative pathogens of meningitis and for examining the clinical course of chemotherapy.
1986-02-01
rates. Target detection times were calculated by averaging response times for all trials within a treatment condition, excluding trials in which...responses in a treatment condition by the total number of valid trials within that condition. Each of these dependent measures was subjected to its own...or 1905 mm). Comparisons among the various treatment means for this effect revealed 13 4~ ~ q-. ~ ~ .-..... 2.309 A EXPERIMENT ONE. 2.29- 0 0 z 2.19
Wood, Britta A; Carver, Scott; Troyer, Ryan M; Elder, John H; VandeWoude, Sue
2013-10-31
Microsphere immunoassays (MIAs) allow rapid and accurate evaluation of multiple analytes simultaneously within a biological sample. Here we describe the development and validation of domestic cat-specific MIAs for a) the quantification of total IgG and IgA levels in plasma, and b) the detection of IgG and IgA antibodies to feline immunodeficiency virus (FIV) capsid (CA) and surface (SU) proteins, and feline CD134 in plasma. These assays were used to examine the temporal antibody response of domestic cats infected with apathogenic and pathogenic FIVs, and domestic cats infected with parental and chimeric FIVs of varying pathogenicity. The results from these studies demonstrated that a) total IgG antibodies increase over time after infection; b) α-CA and α-SU IgG antibodies are detectable between 9 and 28 days post-infection and increase over time, and these antibodies combined represent a fraction (1.8 to 21.8%) of the total IgG increase due to infection; c) measurable α-CD134 IgG antibody levels vary among individuals and over time, and are not strongly correlated with viral load; d) circulating IgA antibodies, in general, do not increase during the early stage of infection; and e) total IgG, and α-CA and α-SU IgG antibody kinetics and levels vary with FIV viral strain/pathogenicity. The MIAs described here could be used to screen domestic cats for FIV infection, and to evaluate the FIV-specific or total antibody response elicited by various FIV strains/other diseases. © 2013.
Wood, Britta A.; Carver, Scott; Troyer, Ryan M.; Elder, John H.; VandeWoude, Sue
2013-01-01
Microsphere immunoassays (MIAs) allow rapid and accurate evaluation of multiple analytes simultaneously within a biological sample. Here we describe the development and validation of domestic cat-specific MIAs for a) the quantification of total IgG and IgA levels in plasma, and b) the detection of IgG and IgA antibodies to feline immunodeficiency virus (FIV) capsid (CA) and surface (SU) proteins, and feline CD134 in plasma. These assays were used to examine the temporal antibody response of domestic cats infected with apathogenic and pathogenic FIVs, and domestic cats infected with parental and chimeric FIVs of varying pathogenicity. The results from these studies demonstrated that a) total IgG antibodies increase over time after infection; b) α-CA and α-SU IgG antibodies are detectable between 9–28 days post-infection and increase over time, and these antibodies combined represent a fraction (1.8 to 21.8%) of the total IgG increase due to infection; c) measurable α-CD134 IgG antibody levels vary among individuals and over time, and are not strongly correlated with viral load; d) circulating IgA antibodies, in general, do not increase during the early stage of infection; and e) total IgG, and α-CA and α-SU IgG antibody kinetics and levels vary with FIV viral strain/pathogenicity. The MIAs described here could be used to screen domestic cats for FIV infection, and to evaluate the FIV-specific or total antibody response elicited by various FIV strains/other diseases. PMID:23954271
Bai, D Y; Zhang, H P; Zhong, S; Suo, W H; Gao, D H; Ding, Y; Tu, J H
2016-12-23
Objective: To investigate the clinical application value of combined detection of ALK fusion gene and c-ros oncogene 1 receptor tyrosine kinase (ROS1) fusion gene in non-small cell lung cancer (NSCLC) using real-time fluorescent PCR. Methods: A kit for combined detection of ALK fusion gene and ROS1 fusion gene based on fluorescent PCR was used to simultaneously detect the two fusion genes in 302 cases of NSCLC specimens. The results were validated through Sanger sequencing. The consistency of the two detection methods was analyzed. Results: All 302 cases of NSCLC specimens were successfully analyzed through fluorescent PCR (302/302). 12 cases (4.0%) were found to contain ALK fusion gene, including 3 cases with ALK-M1, 3 with ALK-M2, 3 with ALK-M3, 1 with ALK-M4, and 2 with ALK-M6 fusion gene.12 cases (4.0%) were found to contain ROS1 fusion gene, including 1 case with ROS1-M7, 8 cases with ROS1-M8, 1 case with ROS1-M12, 1 case with ROS1-M14, and 1 case with double-positive ROS1-M3 and ROS1-M8 fusion genes. The total detection rate of ALK fusion gene and ROS1 fusion gene was 7.9% (24/302) and 278 cases showed to be negative for ALK fusion gene and ROS1 fusion gene. The successful detection rates for Sanger DNA sequencing were also 100%. The positive, negative and total coincidence rates obtained by real-time fluorescent PCR and by Sanger DNA sequencing were all 100%. Conclusions: The results of Sanger DNA sequencing demonstrate that the real-time fluorescent PCR assay is equally effective in detecting ALK and ROS1 fusion genes in NSCLC tissues. Furthermore, real-time fluorescent PCR assay can be used to detect trace ALK and ROS1 fusion gene simultaneously in tiny samples, and can save time and avoid repeated sampling. It is worthy of recommendation as a rapid and reliable detection technique.
Trade Study for Neutron Transport at Low Earth Orbit: Adding Fidelity to DIORAMA
DOE Office of Scientific and Technical Information (OSTI.GOV)
McClanahan, Tucker Caden; Wakeford, Daniel Tyler
The Distributed Infrastructure Offering Real-Time Access to Modeling and Analysis (DIORAMA) software provides performance modeling capabilities of the United States Nuclear Detonation Detection System (USNDS) with a focus on the characterization of Space-Based Nuclear Detonation Detection (SNDD) instrument performance [1]. A case study was done to add the neutron propagation capabilities of DIORAMA to low earth orbit (LEO), and compare the back-calculated incident energy from the time-of- ight (TOF) spectrum with the scored incident energy spectrum. As the scoring altitude lowers, the time increase due to scattering takes up much more of the fraction of total TOF; whereas at geosynchronousmore » earth orbit (GEO), the time increase due to scattering is a negligible fraction of the total TOF [2]. The scattering smears out the TOF enough to make the back-calculation of the initial energy spectrum from the TOF spectrum very convoluted.« less
Fischer, Michael A; Leidner, Bertil; Kartalis, Nikolaos; Svensson, Anders; Aspelin, Peter; Albiin, Nils; Brismar, Torkel B
2014-01-01
To assess feasibility and image quality (IQ) of a new post-processing algorithm for retrospective extraction of an optimised multi-phase CT (time-resolved CT) of the liver from volumetric perfusion imaging. Sixteen patients underwent clinically indicated perfusion CT using 4D spiral mode of dual-source 128-slice CT. Three image sets were reconstructed: motion-corrected and noise-reduced (MCNR) images derived from 4D raw data; maximum and average intensity projections (time MIP/AVG) of the arterial/portal/portal-venous phases and all phases (total MIP/ AVG) derived from retrospective fusion of dedicated MCNR split series. Two readers assessed the IQ, detection rate and evaluation time; one reader assessed image noise and lesion-to-liver contrast. Time-resolved CT was feasible in all patients. Each post-processing step yielded a significant reduction of image noise and evaluation time, maintaining lesion-to-liver contrast. Time MIPs/AVGs showed the highest overall IQ without relevant motion artefacts and best depiction of arterial and portal/portal-venous phases respectively. Time MIPs demonstrated a significantly higher detection rate for arterialised liver lesions than total MIPs/AVGs and the raw data series. Time-resolved CT allows data from volumetric perfusion imaging to be condensed into an optimised multi-phase liver CT, yielding a superior IQ and higher detection rate for arterialised liver lesions than the raw data series. • Four-dimensional computed tomography is limited by motion artefacts and poor image quality. • Time-resolved-CT facilitates 4D-CT data visualisation, segmentation and analysis by condensing raw data. • Time-resolved CT demonstrates better image quality than raw data images. • Time-resolved CT improves detection of arterialised liver lesions in cirrhotic patients.
Swift/XRT detection of an outburst from SXP 15.3
NASA Astrophysics Data System (ADS)
Ducci, L.; Romano, P.; Kennea, J. A.; Malacaria, C.; Covino, S.; Santangelo, A.; Evans, P. A.; Coe, M. J.; Townsend, L. J.
2017-12-01
During an observation of the Small Magellanic Cloud (SMC) carried out from December 2nd 2017, 11:12:03 UT to 19:30:52 UT (total exposure time of 7 ks), Swift/XRT detected renewed activity from the Be X-ray binary SXP 15.3.
NASA Astrophysics Data System (ADS)
Smirnova, J. E.; Zabolotskikh, E. V.; Bobylev, L. P.; Chapron, B.
2016-12-01
In this study polar lows over the Nordic Seas for the period of 1995-2008 have been detected and studied using the Special Sensor Microwave Imager (SSM/I) data. A new methodology for polar low detection and monitoring based on the analysis of the total atmospheric water vapor content (WVC) fields retrieved from SSM/I was used. Lifetimes, diameters, translation speeds, distances traveled, and intensities were estimated for the detected polar lows using SSM/I WVC, sea surface wind speed fields and infrared imagery. Over the Norwegian and Barents Seas, the polar low activity was found to be almost equal. A positive tendency in the total number of polar lows for the time period of 1995-2008 was detected.
Detecting anomalies in astronomical signals using machine learning algorithms embedded in an FPGA
NASA Astrophysics Data System (ADS)
Saez, Alejandro F.; Herrera, Daniel E.
2016-07-01
Taking a large interferometer for radio astronomy, such as the ALMA1 telescope, where the amount of stations (50 in the case of ALMA's main array, which can extend to 64 antennas) produces an enormous amount of data in a short period of time - visibilities can be produced every 16msec or total power information every 1msec (this means up to 2016 baselines). With the aforementioned into account it is becoming more difficult to detect problems in the signal produced by each antenna in a timely manner (one antenna produces 4 x 2GHz spectral windows x 2 polarizations, which means a 16 GHz bandwidth signal which is later digitized using 3-bits samplers). This work will present an approach based on machine learning algorithms for detecting problems in the already digitized signal produced by the active antennas (the set of antennas which is being used in an observation). The aim of this work is to detect unsuitable, or totally corrupted, signals. In addition, this development also provides an almost real time warning which finally helps stop and investigate the problem in order to avoid collecting useless information.
Robertson, J.F.; Nagle, Douglas D.; Rhodes, Liesl C.
1994-01-01
Investigations to provide initial qualitative delineation of petroleum hydrocarbon contamination at three former underground storage tank locations at Fort Jackson, South Carolina, were made during March 1994. Ground-water and sediment samples were collected using direct-push technology and analyzed on-site with a gas chromatograph, which provided real-time, semi-quantitative data. In addition, ground-water and sediment samples were collected at selected sites for laboratory analyses to provide a confirmation of the on-site data. These analyses provided qualitative data on the lateral distri- bution of petroleum hydrocarbons. Petroleum hydrocarbons were detected by on-site analysis in ground-water samples from nine locations at Site 1062, suggesting the presence of a contaminant plume. Concentrations ranged from less than the minimum detection limit to 4,511 mg/L (micrograms per liter) for benzene, 15,594 mg/L for toluene, 16,501 mg/L for ethylbenzene, and 19,391 mg/L for total xylenes. Concentrations of Total Petroleum Hydrocarbons-Gasoline Range Organics ranged from 323 mg/L to 3,364 mg/L; Total Petroleum Hydrocarbons-Diesel Range Organics were not detected. Three samples from this site were analyzed for benzene, toluene, ethylbenzene, and total xylenes at a laboratory and results showed concentrations ranging from less than the minimum detection limit to 1,070 mg/L for benzene, 7,930 mg/L for toluene, 6,890 mg/L for ethylbenzene, and 1,524 mg/L for total xylenes. Petroleum hydro- carbons were detected by on-site analysis in only one sample at Site 2438. A concentration of 131,000 micrograms per kilogram Total Petroleum Hydrocarbons-Diesel Range Organics was detected in sample number GP-2-4-13.5. Petroleum hydrocarbons were detected by on-site analysis in only one ground-water sample from Site 2444. A concentration of 3,145 mg/L Total Petroleum Hydrocarbons-Gasoline Range Organics was detected at sampling location GP-3-2.
Hierro, Núria; Esteve-Zarzoso, Braulio; González, Ángel; Mas, Albert; Guillamón, Jose M.
2006-01-01
Real-time PCR, or quantitative PCR (QPCR), has been developed to rapidly detect and quantify the total number of yeasts in wine without culturing. Universal yeast primers were designed from the variable D1/D2 domains of the 26S rRNA gene. These primers showed good specificity with all the wine yeasts tested, and they did not amplify the most representative wine species of acetic acid bacteria and lactic acid bacteria. Numerous standard curves were constructed with different strains and species grown in yeast extract-peptone-dextrose medium or incubated in wine. The small standard errors with these replicas proved that the assay is reproducible and highly robust. This technique was validated with artificially contaminated and natural wine samples. We also performed a reverse transcription-QPCR (RT-QPCR) assay from rRNA for total viable yeast quantification. This technique had a low detection limit and was more accurate than QPCR because the dead cells were not quantified. As far as we know, this is the first time that RT-QPCR has been performed to quantify viable yeasts from rRNA. RT-QPCR is a rapid and accurate technique for enumerating yeasts during industrial wine fermentation and controlling the risk of wine spoilage. PMID:17088381
Choi, Won Jung; Moon, Jin-Hee; Min, Jae Seok; Song, Yong Keun; Lee, Seung A; Ahn, Jin Woo; Lee, Sang Hun; Jung, Ha Chul
2018-03-01
During minimally invasive surgery (MIS), it is impossible to directly detect marked clips around tumors via palpation. Therefore, we developed a novel method and device using Radio Frequency IDentification (RFID) technology to detect the position of clips during minimally invasive gastrectomy or colectomy. The feasibility of the RFID-based detection system was evaluated in an animal experiment consisting of seven swine. The primary outcome was to successfully detect the location of RFID clips in the stomach and colon. The secondary outcome measures were to detect time (time during the intracorporeal detection of the RFID clip), and accuracy (distance between the RFID clip and the detected site). A total of 25 detection attempts (14 in the stomach and 11 in the colon) using the RFID antenna had a 100% success rate. The median detection time was 32.5 s (range, 15-119 s) for the stomach and 28.0 s (range, 8-87 s) for the colon. The median detection distance was 6.5 mm (range, 4-18 mm) for the stomach and 6.0 mm (range, 3-13 mm) for the colon. We demonstrated favorable results for a RFID system that detects the position of gastric and colon tumors in real-time during MIS. © 2017 Wiley Periodicals, Inc.
Qvarnstrom, Yvonne; Xayavong, Maniphet; da Silva, Ana Cristina Aramburu; Park, Sarah Y.; Whelen, A. Christian; Calimlim, Precilia S.; Sciulli, Rebecca H.; Honda, Stacey A. A.; Higa, Karen; Kitsutani, Paul; Chea, Nora; Heng, Seng; Johnson, Stuart; Graeff-Teixeira, Carlos; Fox, LeAnne M.; da Silva, Alexandre J.
2016-01-01
Angiostrongylus cantonensis is the most common infectious cause of eosinophilic meningitis. Timely diagnosis of these infections is difficult, partly because reliable laboratory diagnostic methods are unavailable. The aim of this study was to evaluate the usefulness of a real-time polymerase chain reaction (PCR) assay for the detection of A. cantonensis DNA in human cerebrospinal fluid (CSF) specimens. A total of 49 CSF specimens from 33 patients with eosinophilic meningitis were included: A. cantonensis DNA was detected in 32 CSF specimens, from 22 patients. Four patients had intermittently positive and negative real-time PCR results on subsequent samples, indicating that the level of A. cantonensis DNA present in CSF may fluctuate during the course of the illness. Immunodiagnosis and/or supplemental PCR testing supported the real-time PCR findings for 30 patients. On the basis of these observations, this real-time PCR assay can be useful to detect A. cantonensis in the CSF from patients with eosinophilic meningitis. PMID:26526920
Sugita, Sunao; Ogawa, Manabu; Inoue, Shizu; Shimizu, Norio; Mochizuki, Manabu
2011-09-01
To establish a two-step polymerase chain reaction (PCR) diagnostic system for ocular toxoplasmosis. A total of 13 ocular fluid samples (11 aqueous humor and 2 vitreous fluid) were collected from 13 patients with clinically suspected ocular toxoplasmosis. Ten ocular samples from other uveitis patients and 20 samples from subjects without ocular inflammation were used as controls. Two polymerase chain reaction (PCR) methods, i.e., qualitative multiplex PCR and quantitative real-time PCR, were used to measure the toxoplasma genome (T. gondii B1 gene). Qualitative multiplex PCR detected T. gondii B1 gene in the ocular fluids of 11 out of 13 patients with clinically suspected ocular toxoplasmosis. In real-time PCR, we detected high copy numbers of T. gondii DNA (5.1 × 10(2)-2.1 × 10(6) copies/mL) in a total of 10 patients (10/13, 77%). Only ocular toxoplasmosis scar lesions were observed in the three real-time PCR-negative patients. PCR assay results for the samples from the two control groups were all negative. The two-step PCR examination to detect toxoplasma DNA is a useful tool for diagnosing ocular toxoplasmosis.
Real-time PCR detection of Brucella spp. DNA in lesions and viscera of bovine carcasses.
Sola, Marília Cristina; da Veiga Jardim, Eurione A G; de Freitas, Marcius Ribeiro; de Mesquita, Albenones José
2014-09-01
This study reports a real-time PCR assay for the detection of Brucella spp. associated with the FTA® Elute method in lesions observed during sanitary inspections in beef slaughter. Of the total 276 samples, 78 (28.3%) tested positive and 198 (71.7%) negative for Brucella spp. The real-time PCR technique associated with the FTA® Elute method proved to be an important tool for the diagnosis, judgment about and disposal of carcasses and viscera of slaughtered animals. Copyright © 2014 Elsevier B.V. All rights reserved.
Comparing distinct ground-based lightning location networks covering the Netherlands
NASA Astrophysics Data System (ADS)
de Vos, Lotte; Leijnse, Hidde; Schmeits, Maurice; Beekhuis, Hans; Poelman, Dieter; Evers, Läslo; Smets, Pieter
2015-04-01
Lightning can be detected using a ground-based sensor network. The Royal Netherlands Meteorological Institute (KNMI) monitors lightning activity in the Netherlands with the so-called FLITS-system; a network combining SAFIR-type sensors. This makes use of Very High Frequency (VHF) as well as Low Frequency (LF) sensors. KNMI has recently decided to replace FLITS by data from a sub-continental network operated by Météorage which makes use of LF sensors only (KNMI Lightning Detection Network, or KLDN). KLDN is compared to the FLITS system, as well as Met Office's long-range Arrival Time Difference (ATDnet), which measures Very Low Frequency (VLF). Special focus lies on the ability to detect Cloud to Ground (CG) and Cloud to Cloud (CC) lightning in the Netherlands. Relative detection efficiency of individual flashes and lightning activity in a more general sense are calculated over a period of almost 5 years. Additionally, the detection efficiency of each system is compared to a ground-truth that is constructed from flashes that are detected by both of the other datasets. Finally, infrasound data is used as a fourth lightning data source for several case studies. Relative performance is found to vary strongly with location and time. As expected, it is found that FLITS detects significantly more CC lightning (because of the strong aptitude of VHF antennas to detect CC), though KLDN and ATDnet detect more CG lightning. We analyze statistics computed over the entire 5-year period, where we look at CG as well as total lightning (CC and CG combined). Statistics that are considered are the Probability of Detection (POD) and the so-called Lightning Activity Detection (LAD). POD is defined as the percentage of reference flashes the system detects compared to the total detections in the reference. LAD is defined as the fraction of system recordings of one or more flashes in predefined area boxes over a certain time period given the fact that the reference detects at least one flash, compared to the total recordings in the reference dataset. The reference for these statistics is taken to be either another dataset, or a dataset consisting of flashes detected by two datasets. Extreme thunderstorm case evaluation shows that the weather alert criterion for severe thunderstorm is reached by FLITS when this is not the case in KLDN and ATD, suggesting the need for KNMI to modify that weather alert criterion when using KLDN.
Hussain, Munira; Soldevila-Pico, Consuelo; Emre, Sukru; Luketic, Velimir; Lok, Anna S F
2007-08-01
Previous studies reported that hepatitis B virus (HBV) deoxyribonucleic acid (DNA) can be detected in livers of patients who received transplants for hepatitis B despite the absence of serological markers of HBV recurrence. Quantification of HBV DNA was not performed and presence of covalently closed circular (ccc) DNA was not analyzed in most studies. We aimed to quantify total and ccc HBV DNA in explant liver and post-orthotopic liver transplantation (OLT) biopsies and to correlate the values with HBV recurrence post-OLT. Frozen liver tissue from 34 patients (9 with explant liver only, 9 with explant liver and post-OLT liver biopsies, and 16 with post-OLT biopsies only) in the National Institutes of Health HBV-OLT study was examined using real-time polymerase chain reaction (PCR). Among the 18 patients with explant liver, 7 were hepatitis B e antigen (HBeAg)-positive, 8 had detectable serum HBV DNA, and 10 received antiviral therapy prior to OLT. Total and ccc HBV DNA was detected in explant livers of 17 and 16 patients, respectively. Of the 10 patients who received antiviral therapy pre-OLT, serum HBV DNA was undetectable in 8 at transplantation but 7 had detectable total and ccc HBV DNA in their explant liver. Of the 25 patients with post-OLT biopsies, total HBV DNA was detected in 83% and ccc DNA in 17% of 47 biopsies, although only 2 patients had HBV recurrence. In conclusion, total and ccc HBV DNA could be detected in explant livers of most patients despite antiviral therapy pre-OLT. Total but not ccc HBV DNA could be detected in post-OLT liver biopsies of most patients despite undetectable serum HBV DNA and hepatitis B surface antigen (HBsAg). Our findings suggest that occult HBV reinfection occurs in most HBV patients after OLT and continued administration of appropriate prophylactic therapy is important in preventing overt HBV recurrence. Copyright (c) 2007 AASLD.
Camargo, Vinícius da Silva; Santana, Bruna Nicoleti; Ferrari, Elis Domingos; Nakamura, Alex Akira; Nagata, Walter Bertequini; Nardi, Ana Rita Moraes; Meireles, Marcelo Vasconcelos
2018-01-01
This study used several diagnostic methods to examine the occurrence of and molecularly characterize Cryptosporidium spp. in captive canaries (Serinus canaria) in southern and southeastern Brazil. A total of 498 fecal samples were purified by centrifugal-flotation using Sheather's solution. Cryptosporidium spp. diagnosis was performed using three diagnostic methods: malachite green negative staining, nested PCR targeting the 18S rRNA gene, followed by sequencing the amplified fragments, and duplex real-time PCR targeting the 18S rRNA specific to detect Cryptosporidium galli and Cryptosporidium avian genotype III. The overall positivity for Cryptosporidium spp. (total samples positive in at least one protocol) from the microscopic analysis, nested PCR and duplex real-time PCR protocol results was 13.3% (66/498). The positivity rates were 2.0% (10/498) and 4.6% (23/498) for Cryptosporidium spp. by microscopy and nested PCR, respectively. Sequencing of 20 samples amplified by nested PCR identified C. galli (3.0%; 15/498), Cryptosporidium avian genotype I (0.8%; 4/498) and Cryptosporidium avium (0.2%; 1/498). Duplex real-time PCR revealed a positivity of 7.8% (39/498) for C. galli and 2.4% (12/498) for avian genotype III. Malachite green negative staining differed significantly from nested PCR in detecting Cryptosporidium spp. Duplex real-time PCR was more sensitive than nested PCR/sequencing for detecting gastric Cryptosporidium in canaries.
Short-term memory for pictures seen once or twice.
Martini, Paolo; Maljkovic, Vera
2009-06-01
The present study is concerned with the effects of exposure time, repetition, spacing and lag on old/new recognition memory for generic visual scenes presented in a RSVP paradigm. Early memory studies with verbal material found that knowledge of total exposure time at study is sufficient to accurately predict memory performance at test (the Total Time Hypothesis), irrespective of number of repetitions, spacing or lag. However, other studies have disputed such simple dependence of memory strength on total study time, demonstrating super-additive facilitatory effects of spacing and lag, as well as inhibitory effects, such as the Ranschburg effect, Repetition Blindness and the Attentional Blink. In the experimental conditions of the present study we find no evidence of either facilitatory or inhibitory effects: recognition memory for pictures in RSVP supports the Total Time Hypothesis. The data are consistent with an Unequal-Variance Signal Detection Theory model of memory that assumes the average strength and the variance of the familiarity of pictures both increase with total study time. The main conclusion is that the growth of visual scene familiarity with temporal exposure and repetition is a stochastically independent process.
Kim, Ji Yeun; Lee, Jung-Lim
2014-10-01
This study describes the first multiplex real-time polymerase chain reaction assay developed, as a multipurpose assessment, for the simultaneous quantification of total bacteria and three Vibrio spp. (V. parahaemolyticus, V. vulnificus and V. anguillarum) in fish and seawater. The consumption of raw finfish as sushi or sashimi has been increasing the chance of Vibrio outbreaks in consumers. Freshness and quality of fishery products also depend on the total bacterial populations present. The detection sensitivity of the specific targets for the multiplex assay was 1 CFU mL⁻¹ in pure culture and seawater, and 10 CFU g⁻¹ in fish. While total bacterial counts by the multiplex assay were similar to those obtained by cultural methods, the levels of Vibrio detected by the multiplex assay were generally higher than by cultural methods of the same populations. Among the natural samples without Vibrio spp. inoculation, eight out of 10 seawater and three out of 20 fish samples were determined to contain Vibrio spp. Our data demonstrate that this multiplex assay could be useful for the rapid detection and quantification of Vibrio spp. and total bacteria as a multipurpose tool for surveillance of fish and water quality as well as diagnostic method. © 2014 The Authors. Journal of the Science of Food and Agriculture published by JohnWiley & Sons Ltd on behalf of Society of Chemical Industry.
Kim, Ji Yeun; Lee, Jung-Lim
2014-01-01
Background This study describes the first multiplex real-time polymerase chain reaction assay developed, as a multipurpose assessment, for the simultaneous quantification of total bacteria and three Vibrio spp. (V. parahaemolyticus, V. vulnificus and V. anguillarum) in fish and seawater. The consumption of raw finfish as sushi or sashimi has been increasing the chance of Vibrio outbreaks in consumers. Freshness and quality of fishery products also depend on the total bacterial populations present. Results The detection sensitivity of the specific targets for the multiplex assay was 1 CFU mL−1 in pure culture and seawater, and 10 CFU g−1 in fish. While total bacterial counts by the multiplex assay were similar to those obtained by cultural methods, the levels of Vibrio detected by the multiplex assay were generally higher than by cultural methods of the same populations. Among the natural samples without Vibrio spp. inoculation, eight out of 10 seawater and three out of 20 fish samples were determined to contain Vibrio spp. Conclusion Our data demonstrate that this multiplex assay could be useful for the rapid detection and quantification of Vibrio spp. and total bacteria as a multipurpose tool for surveillance of fish and water quality as well as diagnostic method. © 2014 The Authors. Journal of the Science of Food and Agriculture published by JohnWiley & Sons Ltd on behalf of Society of Chemical Industry. PMID:24752974
Hua, Yujuan; Hawryluk, Myron; Gras, Ronda; Shearer, Randall; Luong, Jim
2018-01-01
A fast and reliable analytical technique for the determination of total sulfur levels in complex hydrocarbon matrices is introduced. The method employed flow injection technique using a gas chromatograph as a sample introduction device and a gas phase dual-plasma sulfur chemiluminescence detector for sulfur quantification. Using the technique described, total sulfur measurement in challenging hydrocarbon matrices can be achieved in less than 10 s with sample-to-sample time <2 min. The high degree of selectivity and sensitivity toward sulfur compounds of the detector offers the ability to measure low sulfur levels with a detection limit in the range of 20 ppb w/w S. The equimolar response characteristic of the detector allows the quantitation of unknown sulfur compounds and simplifies the calibration process. Response is linear over a concentration range of five orders of magnitude, with a high degree of repeatability. The detector's lack of response to hydrocarbons enables direct analysis without the need for time-consuming sample preparation and chromatographic separation processes. This flow injection-based sulfur chemiluminescence detection technique is ideal for fast analysis or trace sulfur analysis. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Caldwell, Andral W.; Falls, W. Fred; Guimaraes, Wladmir B.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.
2011-01-01
Soil gas and soil were assessed for contaminants at the South Prong Creek Disposal Area at Fort Gordon, Georgia, from October 2009 to September 2010. The assessment included identifying and delineating organic contaminants present in soil-gas and inorganic contaminants present in soil samples collected from the area estimated to be the South Prong Creek Disposal Area, including two seeps and the hyporheic zone. This assessment was conducted to provide environmental contamination data to Fort Gordon personnel pursuant to requirements for the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. All soil-gas samplers in the two seeps and the hyporheic zone contained total petroleum hydrocarbons above the method detection level. The highest total petroleum hydrocarbon concentration detected from the two seeps was 54.23 micrograms per liter, and the highest concentration in the hyporheic zone was 344.41 micrograms per liter. The soil-gas samplers within the boundary of the South Prong Creek Disposal Area and along the unnamed road contained total petroleum hydrocarbon mass above the method detection level. The highest total petroleum hydrocarbon mass detected was 147.09 micrograms in a soil-gas sampler near the middle of the unnamed road that traverses the South Prong Creek Disposal Area. The highest undecane mass detected was 4.48 micrograms near the location of the highest total petroleum hydrocarbon mass. Some soil-gas samplers detected undecane mass greater than the method detection level of 0.04 micrograms, with the highest detection of toluene mass of 109.72 micrograms in the same location as the highest total petroleum hydrocarbon mass. Soil-gas samplers installed in areas of high contaminant mass had no detections of explosives and chemical agents above their respective method detection levels. Inorganic concentrations in five soil samples did not exceed regional screening levels established by the U.S. Environmental Protection Agency. Barium concentrations, however, were up to four times higher than the background concentrations reported in similar Coastal Plain sediments of South Carolina.
Di, Lianjun; Wu, Huichao; Zhu, Rong; Li, Youfeng; Wu, Xinglong; Xie, Rui; Li, Hongping; Wang, Haibo; Zhang, Hua; Xiao, Hong; Chen, Hui; Zhen, Hong; Zhao, Kui; Yang, Xuefeng; Xie, Ming; Tuo, Bigung
2017-12-06
Gastric cancer is a frequent malignant tumor worldwide and its early detection is crucial for curing the disease and enhancing patients' survival rate. This study aimed to assess whether the multi-disciplinary team (MDT) can improve the detection rate of early gastric cancer (EGC). The detection rate of EGC at the Digestive Endoscopy Center, Affiliated Hospital, Zunyi Medical College, China between September 2013 and September 2015 was analyzed. MDT for the diagnosis of EGC in the hospital was established in September 2014. The study was divided into 2 time periods: September 1, 2013 to August 31, 2014 (period 1) and September 1, 2014 to September 1, 2015 (period 2). A total of 60,800 patients' gastroscopies were performed during the two years. 61 of these patients (0.1%) were diagnosed as EGC, accounting for 16.44% (61/371) of total patients with gastric cancer. The EGC detection rate before MDT (period 1) was 0.05% (16/29403), accounting for 9.09% (16/176) of total patients with gastric cancer during this period. In comparison, the EGC detection rate during MDT (period 2) was 0.15% (45/31397), accounting for 23% (45/195) of total patients with gastric cancer during this period (P < 0.05). Univariate and multivariate logistic analyses showed that intensive gastroscopy for high risk patients of gastric cancer enhanced the detection rate of EGC in cooperation with Department of Pathology (OR = 10.1, 95% CI 2.39-43.3, P < 0.05). MDT could improve the endoscopic detection rate of EGC.
NASA Technical Reports Server (NTRS)
Mulholland, J. Derral; Singer, S. Fred; Oliver, John P.; Weinberg, Jerry L.; Cooke, William J.; Kassel, Philip C.; Wortman, Jim J.; Montague, Nancy L.; Kinard, William H.
1991-01-01
During the first 12 months of the Long Duration Exposure Facility (LDEF) mission, the Interplanetary Dust Experiment (IDE) recorded over 15,000 total impacts on six orthogonal faces with a time resolution on the order of 15 to 20 seconds. When combined with the orbital data and the stabilized configuration of the spacecraft, this permits a detailed analysis of the micro-particulate environment. The functional status of each of the 459 detectors was monitored every 2.4 hours, and post-flight analyses of these data has now permitted an evaluation of the effective active detection area as a function of time, panel by panel and separately for the two sensitivity levels. Thus, total impacts were transformed into areal fluxes, and are presented here for the first time. Also discussed are possible effects of these fluxes on previously announced results: apparent debris events, meteor stream detections, and beta meteoroids in observationally significant numbers.
Martín, Maria Cruz; del Rio, Beatriz; Martínez, Noelia; Magadán, Alfonso H; Alvarez, Miguel A
2008-12-01
One of the main microbiological problems of the dairy industry is the susceptibility of starter bacteria to virus infections. Lactobacillus delbrueckii, a component of thermophilic starter cultures used in the manufacture of several fermented dairy products, including yogurt, is also sensitive to bacteriophage attacks. To avoid the problems associated with these viruses, quick and sensitive detection methods are necessary. In the present study, a fast real-time quantitative polymerase chain reaction assay for the direct detection and quantification of L. delbrueckii phages in milk was developed. A set of primers and a TaqMan MGB probe was designed, based on the lysin gene sequence of different L. delbrueckii phages. The results show the proposed method to be a rapid (total processing time 30 min), specific and highly sensitive technique for detecting L. delbrueckii phages in milk.
NASA Astrophysics Data System (ADS)
Streli, C.; Pepponi, G.; Wobrauschek, P.; Jokubonis, C.; Falkenberg, G.; Záray, G.; Broekaert, J.; Fittschen, U.; Peschel, B.
2006-11-01
At the Hamburger Synchrotronstrahlungslabor (HASYLAB), Beamline L, a vacuum chamber for synchrotron radiation-induced total reflection X-ray fluorescence analysis, is now available which can easily be installed using the adjustment components for microanalysis present at this beamline. The detector is now in the final version of a Vortex silicon drift detector with 50-mm 2 active area from Radiant Detector Technologies. With the Ni/C multilayer monochromator set to 17 keV extrapolated detection limits of 8 fg were obtained using the 50-mm 2 silicon drift detector with 1000 s live time on a sample containing 100 pg of Ni. Various applications are presented, especially of samples which are available in very small amounts: As synchrotron radiation-induced total reflection X-ray fluorescence analysis is much more sensitive than tube-excited total reflection X-ray fluorescence analysis, the sampling time of aerosol samples can be diminished, resulting in a more precise time resolution of atmospheric events. Aerosols, directly sampled on Si reflectors in an impactor were investigated. A further application was the determination of contamination elements in a slurry of high-purity Al 2O 3. No digestion is required; the sample is pipetted and dried before analysis. A comparison with laboratory total reflection X-ray fluorescence analysis showed the higher sensitivity of synchrotron radiation-induced total reflection X-ray fluorescence analysis, more contamination elements could be detected. Using the Si-111 crystal monochromator also available at beamline L, XANES measurements to determine the chemical state were performed. This is only possible with lower sensitivity as the flux transmitted by the crystal monochromator is about a factor of 100 lower than that transmitted by the multilayer monochromator. Preliminary results of X-ray absorption near-edge structure measurements for As in xylem sap from cucumber plants fed with As(III) and As(V) are reported. Detection limits of 170 ng/l of As in xylem sap were achieved.
Determination of opiates and cocaine in urine by high pH mobile phase reversed phase UPLC-MS/MS.
Berg, Thomas; Lundanes, Elsa; Christophersen, Asbjørg S; Strand, Dag Helge
2009-02-01
A fast and selective ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the determination of opiates (morphine, codeine, 6-monoacetylmorphine (6-MAM), pholcodine, oxycodone, ethylmorphine), cocaine and benzoylecgonine in urine has been developed and validated. Sample preparation was performed by solid phase extraction (SPE) on a mixed mode cation exchange (MCX) cartridge. For optimized chromatographic performance with repeatable retention times, narrow and symmetrical peaks, and focusing of all analytes at the column inlet at gradient start, a basic mobile phase consisting of 5mM ammonium bicarbonate, pH 10.2, and methanol (MeOH) was chosen. Positive electrospray ionization (ESI(+)) MS/MS detection was performed with a minimum of two multiple reaction monitoring (MRM) transitions for each analyte. Deuterium labelled-internal standards were used for six of the analytes. Between-assay retention time repeatabilities (n=10 series, 225 injections in total) had relative standard deviation (RSD) values within 0.1-0.6%. Limit of detection (LOD) and limit of quantification (LOQ) values were in the range 0.003-0.05 microM (0.001-0.02 microg/mL) and 0.01-0.16 microM (0.003-0.06 microg/mL), respectively. The RSD values of the between-assay repeatabilities of concentrations were
In vitro pleural fluid clottability and fibrinogen content.
Glauser, F L; Otis, P T; Levine, R I; Smith, W R
1975-08-01
Twenty-three specimens of pleural fluid from 23 patients were examined for quantitative fibrinogen, total protein levels, and for clottability in vitro using the recalcification time. Of the 19 specimens of pleural fluid from patients without loculation, 11 (seven exudates) had no detectable fibrinogen; another 8 (six exudates) had a mean fibrinogen level of 55.0 +/- 10.2 mg percent, and a mean recalcification time of 19.4 +/- 2.6 minutes. The pleural fluids from the four patients with loculation had no detectable fibrinogen. The only fluids containing fibrinolytic activity were from the nonloculated non-fibrinogen-containing group. No correlation existed between pleural fluid/plasma total protein ratios and pleural fluid/plasma fibrinogen ratios. In vitro clottability in this study did not reflect the in vivo tendency for coagulation and loculation.
Martin, Audrey N; Farquar, George R; Frank, Matthias; Gard, Eric E; Fergenson, David P
2007-08-15
Single-particle aerosol mass spectrometry (SPAMS) was used for the real-time detection of liquid nerve agent simulants. A total of 1000 dual-polarity time-of-flight mass spectra were obtained for micrometer-sized single particles each of dimethyl methyl phosphonate, diethyl ethyl phosphonate, diethyl phosphoramidate, and diethyl phthalate using laser fluences between 0.58 and 7.83 nJ/microm2, and mass spectral variation with laser fluence was studied. The mass spectra obtained allowed identification of single particles of the chemical warfare agent (CWA) simulants at each laser fluence used although lower laser fluences allowed more facile identification. SPAMS is presented as a promising real-time detection system for the presence of CWAs.
Martin, F Elizabeth; Nadkarni, Mangala A; Jacques, Nicholas A; Hunter, Neil
2002-05-01
The bacteria found in carious dentine were correlated with the tissue response of the dental pulps of 65 teeth extracted from patients with advanced caries and pulpitis. Standardized homogenates of carious dentine were plated onto selective and nonselective media under anaerobic and microaerophilic conditions. In addition, real-time PCR was used to quantify the recovery of anaerobic bacteria. Primers and fluorogenic probes were designed to detect the total anaerobic microbial load, the genera Prevotella and Fusobacterium, and the species Prevotella melaninogenica, Porphyromonas endodontalis, Porphyromonas gingivalis, and Micromonas (formerly Peptostreptococcus) micros. The pulpal pathology was categorized according to the cellular response and degenerative changes. Analysis of cultured bacteria showed a predominance of gram-positive microorganisms, particularly lactobacilli. Gram-negative bacteria were also present in significant numbers with Prevotella spp., the most numerous anaerobic group cultured. Real-time PCR analysis indicated a greater microbial load than that determined by colony counting. The total number of anaerobes detected was 41-fold greater by real-time PCR than by colony counting, while the numbers of Prevotella and Fusobacterium spp. detected were 82- and 2.4-fold greater by real-time PCR than by colony counting, respectively. Real-time PCR also identified M. micros, P. endodontalis, and P. gingivalis in 71, 60, and 52% of carious samples, respectively. Correlation matrices of the real-time PCR data revealed significant positive associations between M. micros and P. endodontalis detection and inflammatory degeneration of pulpal tissues. These anaerobes have been strongly implicated in endodontic infections that occur as sequelae to carious pulpitis. Accordingly, the data suggest that the presence of high levels of these bacteria in carious lesions may be indicative of irreversible pulpal pathology.
Background The purpose of this study was to improve the current method for detecting differentially-oxidized (carbonyl-modified) proteins by 2D-DIGE, while at the same time determining changes in total protein expression. Protein oxidation is a widely accepted model of aging and...
NASA Astrophysics Data System (ADS)
Kelley, Luke Zoltan; Blecha, Laura; Hernquist, Lars; Sesana, Alberto; Taylor, Stephen R.
2018-06-01
We calculate the properties, occurrence rates and detection prospects of individually resolvable `single sources' in the low-frequency gravitational wave (GW) spectrum. Our simulations use the population of galaxies and massive black hole binaries from the Illustris cosmological hydrodynamic simulations, coupled to comprehensive semi-analytic models of the binary merger process. Using mock pulsar timing arrays (PTA) with, for the first time, varying red-noise models, we calculate plausible detection prospects for GW single sources and the stochastic GW background (GWB). Contrary to previous results, we find that single sources are at least as detectable as the GW background. Using mock PTA, we find that these `foreground' sources (also `deterministic'/`continuous') are likely to be detected with ˜20 yr total observing baselines. Detection prospects, and indeed the overall properties of single sources, are only moderately sensitive to binary evolution parameters - namely eccentricity and environmental coupling, which can lead to differences of ˜5 yr in times to detection. Red noise has a stronger effect, roughly doubling the time to detection of the foreground between a white-noise only model (˜10-15 yr) and severe red noise (˜20-30 yr). The effect of red noise on the GWB is even stronger, suggesting that single source detections may be more robust. We find that typical signal-to-noise ratios for the foreground peak near f = 0.1 yr-1, and are much less sensitive to the continued addition of new pulsars to PTA.
Effects of the Sagittarius dwarf tidal stream on dark matter detectors.
Freese, Katherine; Gondolo, Paolo; Newberg, Heidi Jo; Lewis, Matthew
2004-03-19
The Sagittarius dwarf tidal stream may be showering dark matter onto the solar neighborhood, which can change the results and interpretation of direct detection searches for weakly interacting massive particles (WIMPs). Stars in the stream may already have been detected in the solar neighborhood, and the dark matter in the stream is (0.3-25)% of the local density. Experiments should see an annually modulated steplike feature in the energy recoil spectrum that would be a smoking gun for WIMP detection. The total count rate in detectors is not a cosine curve in time and peaks at a different time of year than the standard case.
Maier, C; Dickhaus, H
2010-01-01
This study examines the suitability of recurrence plot analysis for the problem of central sleep apnea (CSA) detection and delineation from ECG-derived respiratory (EDR) signals. A parameter describing the average length of vertical line structures in recurrence plots is calculated at a time resolution of 1 s as 'instantaneous trapping time'. Threshold comparison of this parameter is used to detect ongoing CSA. In data from 26 patients (duration 208 h) we assessed sensitivity for detection of CSA and mixed apnea (MSA) events by comparing the results obtained from 8-channel Holter ECGs to the annotations (860 CSA, 480 MSA) of simultaneously registered polysomnograms. Multivariate combination of the EDR from different ECG leads improved the detection accuracy significantly. When all eight leads were considered, an average instantaneous vertical line length above 5 correctly identified 1126 of the 1340 events (sensitivity 84%) with a total number of 1881 positive detections. We conclude that recurrence plot analysis is a promising tool for detection and delineation of CSA epochs from EDR signals with high time resolution. Moreover, the approach is likewise applicable to directly measured respiratory signals.
Qvarnstrom, Yvonne; Xayavong, Maniphet; da Silva, Ana Cristina Aramburu; Park, Sarah Y; Whelen, A Christian; Calimlim, Precilia S; Sciulli, Rebecca H; Honda, Stacey A A; Higa, Karen; Kitsutani, Paul; Chea, Nora; Heng, Seng; Johnson, Stuart; Graeff-Teixeira, Carlos; Fox, LeAnne M; da Silva, Alexandre J
2016-01-01
Angiostrongylus cantonensis is the most common infectious cause of eosinophilic meningitis. Timely diagnosis of these infections is difficult, partly because reliable laboratory diagnostic methods are unavailable. The aim of this study was to evaluate the usefulness of a real-time polymerase chain reaction (PCR) assay for the detection of A. cantonensis DNA in human cerebrospinal fluid (CSF) specimens. A total of 49 CSF specimens from 33 patients with eosinophilic meningitis were included: A. cantonensis DNA was detected in 32 CSF specimens, from 22 patients. Four patients had intermittently positive and negative real-time PCR results on subsequent samples, indicating that the level of A. cantonensis DNA present in CSF may fluctuate during the course of the illness. Immunodiagnosis and/or supplemental PCR testing supported the real-time PCR findings for 30 patients. On the basis of these observations, this real-time PCR assay can be useful to detect A. cantonensis in the CSF from patients with eosinophilic meningitis. © The American Society of Tropical Medicine and Hygiene.
Clancy, Eoin; Coughlan, Helena; Higgins, Owen; Boo, Teck Wee; Cormican, Martin; Barrett, Louise; Smith, Terry J; Reddington, Kate; Barry, Thomas
2016-08-01
Three duplex molecular beacon based real-time Nucleic Acid Sequence Based Amplification (NASBA) assays have been designed and experimentally validated targeting RNA transcripts for the detection and identification of Haemophilus influenzae, Neisseria meningitidis and Streptococcus pneumoniae respectively. Each real-time NASBA diagnostics assay includes an endogenous non-competitive Internal Amplification Control (IAC) to amplify the splice variant 1 mRNA of the Homo sapiens TBP gene from human total RNA. All three duplex real-time NASBA diagnostics assays were determined to be 100% specific for the target species tested for. Also the Limits of Detection (LODs) for the H. influenzae, N. meningitidis and S. pneumoniae duplex real-time NASBA assays were 55.36, 0.99, and 57.24 Cell Equivalents (CE) respectively. These robust duplex real-time NASBA diagnostics assays have the potential to be used in a clinical setting for the rapid (<60min) specific detection and identification of the most prominent microorganisms associated with bacterial meningitis in humans. Copyright © 2016 Elsevier B.V. All rights reserved.
Majid, Farjana; Jahan, Munira; Lutful Moben, Ahmed; Tabassum, Shahina
2014-01-01
Both real-time-polymerase chain reaction (PCR) and hybrid capture 2 (HC2) assay can detect and quantify hepatitis B virus (HBV) DNA. However, real-time-PCR can detect a wide range of HBV DNA, while HC2 assay could not detect lower levels of viremia. The present study was designed to detect and quantify HBV DNA by real-time-PCR and HC2 assay and compare the quantitative data of these two assays. A cross-sectional study was conducted in between July 2010 and June 2011. A total of 66 serologically diagnosed chronic hepatitis B (CHB) patients were selected for the study. Real-time-PCR and HC2 assay was done to detect HBV DNA. Data were analyzed by statistical Package for the social sciences (SPSS). Among 66 serologically diagnosed chronic hepatitis B patients 40 (60.61%) patients had detectable and 26 (39.39%) had undetectable HBV DNA by HC2 assay. Concordant results were obtained for 40 (60.61%) out of these 66 patients by real-time-PCR and HC2 assay with mean viral load of 7.06 ± 1.13 log 10 copies/ml and 6.95 ± 1.08 log 10 copies/ml, respectively. In the remaining 26 patients, HBV DNA was detectable by real-time-PCR in 20 patients (mean HBV DNA level was 3.67 ± 0.72 log 10 copies/ml. However, HBV DNA could not be detectable in six cases by the both assays. The study showed strong correlation (r = 0.915) between real-time-PCR and HC2 assay for the detection and quantification of HBV DNA. HC2 assay may be used as an alternative to real-time-PCR for CHB patients. How to cite this article: Majid F, Jahan M, Moben AL, Tabassum S. Comparison of Hybrid Capture 2 Assay with Real-time-PCR for Detection and Quantitation of Hepatitis B Virus DNA. Euroasian J Hepato-Gastroenterol 2014;4(1):31-35.
Fatemeh, Dehghan; Reza, Zolfaghari Mohammad; Mohammad, Arjomandzadegan; Salomeh, Kalantari; Reza, Ahmari Gholam; Hossein, Sarmadian; Maryam, Sadrnia; Azam, Ahmadi; Mana, Shojapoor; Negin, Najarian; Reza, Kasravi Alii; Saeed, Falahat
2014-01-01
Objective To analyse molecular detection of coliforms and shorten the time of PCR. Methods Rapid detection of coliforms by amplification of lacZ and uidA genes in a multiplex PCR reaction was designed and performed in comparison with most probably number (MPN) method for 16 artificial and 101 field samples. The molecular method was also conducted on isolated coliforms from positive MPN samples; standard sample for verification of microbial method certificated reference material; isolated strains from certificated reference material and standard bacteria. The PCR and electrophoresis parameters were changed for reducing the operation time. Results Results of PCR for lacZ and uidA genes were similar in all of standard, operational and artificial samples and showed the 876 bp and 147 bp bands of lacZ and uidA genes by multiplex PCR. PCR results were confirmed by MPN culture method by sensitivity 86% (95% CI: 0.71-0.93). Also the total execution time, with a successful change of factors, was reduced to less than two and a half hour. Conclusions Multiplex PCR method with shortened operation time was used for the simultaneous detection of total coliforms and Escherichia coli in distribution system of Arak city. It's recommended to be used at least as an initial screening test, and then the positive samples could be randomly tested by MPN. PMID:25182727
Melamine detection in infant formula powder using near- and mid-infrared spectroscopy.
Mauer, Lisa J; Chernyshova, Alona A; Hiatt, Ashley; Deering, Amanda; Davis, Reeta
2009-05-27
Near- and mid-infrared spectroscopy methods (NIR, FTIR-ATR, FTIR-DRIFT) were evaluated for the detection and quantification of melamine in infant formula powder. Partial least-squares (PLS) models were established for correlating spectral data to melamine concentration: R(2) > 0.99, RMSECV ≤ 0.9, and RPD ≥ 12. Factorization analysis of spectra was able to differentiate unadulterated infant formula powder from samples containing 1 ppm melamine with no misclassifications, a confidence level of 99.99%, and selectivity > 2. These nondestructive methods require little or no sample preparation. The NIR method has an assay time of 1 min, and a 2 min total time to detection. The FTIR methods require up to 5 min for melamine detection. Therefore, NIR and FTIR methods enable rapid detection of 1 ppm melamine in infant formula powder.
The Miniaturized Moessbauer Spectrometers MIMOS II on MER: Four Years of Operation - A Summary
NASA Technical Reports Server (NTRS)
Fleischer, I.; Klingelhoefer, G.; Morris, R. V.; Rodionov, D.; Blumers, M.; Bernhardt, B.; Schroeder, C.; Ming, D. W.; Yen, A. S.; Cohen, B. A.;
2008-01-01
The two Miniaturized Moessbauer Spectrometers (MIMOS II) on board the two Mars Exploration Rovers Spirit and Opportunity have now been collecting important scientific data for more than four years. The spectrometers provide information about Fe-bearing mineral phases and determine Fe oxidation states. The total amount of targets analized exceeds 600, the total integration time exceeds 260 days for both rovers. Since landing, more than five half-lives of the Co-57 MB sources have past (intensity at the time of landing approx. 150 mCi). Current integration times are about 50 hours in order to achieve reasonable statistics as opposed to 8 hours at the beginning of the mission. In total, 13 different mineral phases were detected: Olivine, pyroxene, hematite, magnetite and nanophase ferric oxide were detected at both landing sites. At Gusev, ilmenite, goethite, a ferric sulfate phase and a yet unassigned phase (in the rock Fuzzy Smith) were detected. At Meridiani, jarosite, metallic iron in meteoritic samples (kamacite), troilite, and an unassigned ferric phase were detected. Jarosite and goethite are of special interest, as these minerals are indicators for water activity. In this abstract, an overview of Moessbauer results will be given, with a focus on data obtained since the last martian winter. The MER mission has proven that Moessbauer spectroscopy is a valuable tool for the in situ exploration of extraterrestrial bodies and for the study of Febearing samples. The experience gained through the MER mission makes MIMOS II a obvious choice for future missions to Mars and other targets. Currently, MIMOS II is on the scientific payload of two approved future missions: Phobos Grunt (Russian Space Agency; 2009) and ExoMars (European Space Agency; 2013).
NASA Astrophysics Data System (ADS)
Li, Mei; Parrot, Michel
2018-02-01
Results of a statistical variation of total ion density observed in the vicinity of epicenters as well as around magnetically conjugated points of earthquakes are presented in this paper. Two data sets are used: the ion density measured by DEMETER during about 6.5 years and the list of strong earthquakes (MW ≥ 4.8) occurring globally during this period (14,764 earthquakes in total). First of all, ionospheric perturbations with 23-120 s observation time corresponding to spatial scales of 160-840 km are automatically detected by a software (64,287 anomalies in total). Second, it is checked if a perturbation could be associated either with the epicenter of an earthquake or with its magnetically conjugated point (distance < 1500 km and time < 15 days before the earthquake). The index Kp < 3 is also considered in order to reduce the effect of the geomagnetic activity on the ionosphere during this period. The results show that it is possible to detect variations of the ionospheric parameters above the epicenter areas as well as above their conjugated points. About one third of the earthquakes are detected with ionospheric influence on both sides of the Earth. There is a trend showing that the perturbation length increases as the magnitude of the detected EQs but it is more obvious for large magnitude. The probability that a perturbation appears is higher on the day of the earthquake and then gradually decreases when the time before the earthquake increases. The spatial distribution of perturbations shows that the probability of perturbations appearing southeast of the epicenter before an earthquake is a little bit higher and that there is an obvious trend because perturbations appear west of the conjugated point of an earthquake.
Wah, Tze Min; Sourbron, Steven; Wilson, Daniel Jonathan; Magee, Derek; Gregory, Walter Martin; Selby, Peter John; Buckley, David L
2018-01-08
To investigate if the early treatment effects of radiofrequency ablation (RFA) on renal cell carcinoma (RCC) can be detected with dynamic contrast enhanced (DCE)-MRI and to correlate RCC perfusion with RFA treatment time. 20 patients undergoing RFA of their 21 RCCs were evaluated with DCE-MRI before and at one month after RFA treatment. Perfusion was estimated using the maximum slope technique at two independent sittings. Total RCC blood flow was correlated with total RFA treatment time, tumour location, size and histology. DCE-MRI examinations were successfully evaluated for 21 RCCs (size from 1.3 to 4 cm). Perfusion of the RCCs decreased significantly ( p < 0.0001) from a mean of 203 (±80) mL/min/100 mL before RFA to 8.1 (±3.1) mL/min/100 mL after RFA with low intra-observer variability ( r ≥ 0.99, p < 0.0001). There was an excellent correlation ( r = 0.95) between time to complete ablation and pre-treatment total RCC blood flow. Tumours with an exophytic location exhibit the lowest mean RFA treatment time. DCE-MRI can detect early treatment effects by measuring RCC perfusion before and after RFA. Perfusion significantly decreases in the zone of ablation, suggesting that it may be useful for the assessment of treatment efficacy. Pre-RFA RCC blood flow may be used to predict RFA treatment time.
Surase, P V; Nataraj, G; Pattamadai, K; Mehta, P R; Pazare, A R; Agarwal, M C; Nanavati, R N
2016-01-01
Comparison of conventional blood culture with BACTEC 9050 for rate and time to detection of microorganisms. A prospective study was carried out in a multispecialty tertiary care teaching hospital. A total of 835 paired specimens (797 blood and 38 nonblood specimens) were collected and processed according to standard microbiological procedures by both conventional method as well as by BACTEC 9050 automated culture system. Clinical details of patients were recorded. Data were analyzed for time to detection and isolation rate by the two systems and compared. Overall culture positivity for BACTEC 9050 and the conventional system was 32% and 19.88%, respectively. Eighty-five demonstrated concordant growth, 136 specimens were culture positive by BACTEC only, and 38 specimens were culture positive by conventional only. Twelve contaminants in BACTEC and nine contaminants in conventional system were detected. Using BACTEC 9050, higher isolation was observed for Acinetobacter spp., coagulase negative Staphylococcus spp., Streptococcus spp., and Candida spp. A total of 410 patients were on antimicrobial treatment and culture positivity was significantly higher with BACTEC 9050 (P < 0.0001). There was a significant difference in the mean time to detection with BACTEC 9050 recovering 86.8% of isolates within 48 h (P < 0.0001). Although BACTEC 9050 demonstrated a significantly higher recovery of microorganisms from blood, an appropriately performed conventional blood culture can facilitate the choice of therapy.
Santos-Reis, Margarida; Picanço de Figueiredo, Almir; Bager, Alex; Aguiar, Ludmilla M. S.
2016-01-01
Carcass persistence time and detectability are two main sources of uncertainty on roadkill surveys. In this study, we evaluate the influence of these uncertainties on roadkill surveys and estimates. To estimate carcass persistence time, three observers (including the driver) surveyed 114km by car on a monthly basis for two years, searching for wildlife-vehicle collisions (WVC). Each survey consisted of five consecutive days. To estimate carcass detectability, we randomly selected stretches of 500m to be also surveyed on foot by two other observers (total 292 walked stretches, 146 km walked). We expected that body size of the carcass, road type, presence of scavengers and weather conditions to be the main drivers influencing the carcass persistence times, but their relative importance was unknown. We also expected detectability to be highly dependent on body size. Overall, we recorded low median persistence times (one day) and low detectability (<10%) for all vertebrates. The results indicate that body size and landscape cover (as a surrogate of scavengers’ presence) are the major drivers of carcass persistence. Detectability was lower for animals with body mass less than 100g when compared to carcass with higher body mass. We estimated that our recorded mortality rates underestimated actual values of mortality by 2–10 fold. Although persistence times were similar to previous studies, the detectability rates here described are very different from previous studies. The results suggest that detectability is the main source of bias across WVC studies. Therefore, more than persistence times, studies should carefully account for differing detectability when comparing WVC studies. PMID:27806125
An Abbreviated Protocol for High-Risk Screening Breast MRI Saves Time and Resources.
Harvey, Susan C; Di Carlo, Phillip A; Lee, Bonmyong; Obadina, Eniola; Sippo, Dorothy; Mullen, Lisa
2016-04-01
To review the ability of an abbreviated, high-risk, screening, breast MRI protocol to detect cancer and save resources. High-risk screening breast MR images were reviewed, from both an abbreviated protocol and a full diagnostic protocol. Differences in cancer detection, scanner utilization, interpretation times, and need for additional imaging were recorded in an integrated data form, and reviewed and compared. A total of 568 MRI cases were reviewed, with the abbreviated and full protocols. No difference was found in the number of cancers detected. Scan times were decreased by 18.8 minutes per case, for a total of 10,678 minutes (178 hours). Interpretation time, on average, was 1.55 minutes for the abbreviated protocol, compared with 6.43 minutes for the full protocol. Review of the full protocol led to a significant change in the final BI-RADS(®) assessment in 12 of 568 (2.1%) cases. Abbreviated MRI is as effective as full-protocol MRI for demonstration of cancers in the high-risk screening setting, with only 12 (2.1%) cases recommended for additional MRI evaluation. The efficiency and resource savings of an abbreviated protocol would be significant, and would allow for opportunities to provide MRI for additional patients, as well as improved radiologist time management and workflow, with the potential to add real-time MRI interpretation or double reading. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
An Abbreviated Protocol for High-Risk Screening Breast MRI Saves Time and Resources.
Harvey, Susan C; Di Carlo, Phillip A; Lee, Bonmyong; Obadina, Eniola; Sippo, Dorothy; Mullen, Lisa
2016-11-01
To review the ability of an abbreviated, high-risk, screening, breast MRI protocol to detect cancer and save resources. High-risk screening breast MR images were reviewed, from both an abbreviated protocol and a full diagnostic protocol. Differences in cancer detection, scanner utilization, interpretation times, and need for additional imaging were recorded in an integrated data form, and reviewed and compared. A total of 568 MRI cases were reviewed, with the abbreviated and full protocols. No difference was found in the number of cancers detected. Scan times were decreased by 18.8 minutes per case, for a total of 10,678 minutes (178 hours). Interpretation time, on average, was 1.55 minutes for the abbreviated protocol, compared with 6.43 minutes for the full protocol. Review of the full protocol led to a significant change in the final BI-RADS ® assessment in 12 of 568 (2.1%) cases. Abbreviated MRI is as effective as full-protocol MRI for demonstration of cancers in the high-risk screening setting, with only 12 (2.1 %) cases recommended for additional MRI evaluation. The efficiency and resource savings of an abbreviated protocol would be significant, and would allow for opportunities to provide MRI for additional patients, as well as improved radiologist time management and workflow, with the potential to add real-time MRI interpretation or double reading. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Syndromic surveillance for health information system failures: a feasibility study.
Ong, Mei-Sing; Magrabi, Farah; Coiera, Enrico
2013-05-01
To explore the applicability of a syndromic surveillance method to the early detection of health information technology (HIT) system failures. A syndromic surveillance system was developed to monitor a laboratory information system at a tertiary hospital. Four indices were monitored: (1) total laboratory records being created; (2) total records with missing results; (3) average serum potassium results; and (4) total duplicated tests on a patient. The goal was to detect HIT system failures causing: data loss at the record level; data loss at the field level; erroneous data; and unintended duplication of data. Time-series models of the indices were constructed, and statistical process control charts were used to detect unexpected behaviors. The ability of the models to detect HIT system failures was evaluated using simulated failures, each lasting for 24 h, with error rates ranging from 1% to 35%. In detecting data loss at the record level, the model achieved a sensitivity of 0.26 when the simulated error rate was 1%, while maintaining a specificity of 0.98. Detection performance improved with increasing error rates, achieving a perfect sensitivity when the error rate was 35%. In the detection of missing results, erroneous serum potassium results and unintended repetition of tests, perfect sensitivity was attained when the error rate was as small as 5%. Decreasing the error rate to 1% resulted in a drop in sensitivity to 0.65-0.85. Syndromic surveillance methods can potentially be applied to monitor HIT systems, to facilitate the early detection of failures.
Assessing and validating RST-FIRES on MSG-SEVIRI data by means a Total Validation Approach (TVA).
NASA Astrophysics Data System (ADS)
Filizzola, Carolina; Corrado, Rosita; Marchese, Francesco; Mazzeo, %Giuseppe; Paciello, Rossana; Pergola, Nicola; Tramutoli, Valerio
2015-04-01
Several fire detection methods have been developed through the years for detecting forest fires from space. These algorithms (which may be grouped in single channel, multichannel and contextual algorithms) are generally based on the use of fixed thresholds that, being intrinsically exposed to false alarm proliferation, are often used in a conservative way. As a consequence, most of satellite-based algorithms for fire detection show low sensitivity resulting not suitable in operational contexts. In this work, the RST-FIRES algorithm, which is based on an original multi-temporal scheme of satellite data analysis (RST-Robust Satellite Techniques), is presented. The implementation of RST-FIRES on data provided by Spinning Enhanced Visible and InfraRed Imager (SEVIRI) onboard Meteosat Second Generation (MSG) that, offering the best revisit time (i.e. 15 minutes), can be successfully used for detecting fires at early stage, is described here. Moreover, results of a Total Validation Approach (TVA) experimented both in Northern and Southern Italy, in collaboration with local and regional civil protection agencies, are also reported. In particular, TVA allowed us to assess RST-FIRES detections by means of ground check and aerial surveys, demonstrating the good performances offered by RST-FIRES using MSG-SEVIRI data. Indeed, this algorithm was capable of detecting several fires that for their features (e.g., small size, short time duration) would not have appeared in the official reports, highlighting a significant improvement in terms of sensitivity in comparison with other established satellite-based fire detection techniques still preserving a high confidence level of detection.
Liu, Ai-Hua; Guo, Hui; Ye, Min; Lin, Yan-Hua; Sun, Jiang-Hao; Xu, Man; Guo, De-An
2007-08-17
By using HPLC-diode array detection-electrospray ion trap tandem mass spectrometry (HPLC-DAD-ESI-MS(n)) in negative ion mode, we have analyzed the fragmentation pathways of 11 phenolic acids which were isolated from Danshen. Then the extract of Danshen was analyzed, and a total of 42 phenolic acids, including sixteen new minor constituents, were identified or tentatively identified for the first time. A new solid-phase extraction (SPE) method, new HPLC separation method, new liquid chromatography (LC)-MS and LC-MS(n) (n=3-5) data and proposed fragmentation pathways, LC retention time for phenolic acids are reported.
Landsat change detection can aid in water quality monitoring
NASA Technical Reports Server (NTRS)
Macdonald, H. C.; Steele, K. F.; Waite, W. P.; Shinn, M. R.
1977-01-01
Comparison between Landsat-1 and -2 imagery of Arkansas provided evidence of significant land use changes during the 1972-75 time period. Analysis of Arkansas historical water quality information has shown conclusively that whereas point source pollution generally can be detected by use of water quality data collected by state and federal agencies, sampling methodologies for nonpoint source contamination attributable to surface runoff are totally inadequate. The expensive undertaking of monitoring all nonpoint sources for numerous watersheds can be lessened by implementing Landsat change detection analyses.
Selective cultivation and rapid detection of Staphylococcus aureus by computer vision.
Wang, Yong; Yin, Yongguang; Zhang, Chaonan
2014-03-01
In this paper, we developed a selective growth medium and a more rapid detection method based on computer vision for selective isolation and identification of Staphylococcus aureus from foods. The selective medium consisted of tryptic soy broth basal medium, 3 inhibitors (NaCl, K2 TeO3 , and phenethyl alcohol), and 2 accelerators (sodium pyruvate and glycine). After 4 h of selective cultivation, bacterial detection was accomplished using computer vision. The total analysis time was 5 h. Compared to the Baird-Parker plate count method, which requires 4 to 5 d, this new detection method offers great time savings. Moreover, our novel method had a correlation coefficient of greater than 0.998 when compared with the Baird-Parker plate count method. The detection range for S. aureus was 10 to 10(7) CFU/mL. Our new, rapid detection method for microorganisms in foods has great potential for routine food safety control and microbiological detection applications. © 2014 Institute of Food Technologists®
Jagucki, Martha L.; Kula, Stephanie P.; Mailot, Brian E.
2015-01-01
To evaluate whether constituent concentrations consistently increased or decreased over time, the strength of the association between sampling year (time) and constituent concentration was statistically evaluated for 116 water-quality samples collected by the USGS in 1978, 1980, 1986, 1999, and 2009 from a total of 65 wells across the county (generally domestic wells or wells serving small businesses or churches). Results indicate that many of the constituents that have been analyzed for decades exhibited no consistent temporal trends at a statistically significant level (p-value less than 0.05); fluctuations in concentrations of these constituents represent natural variation in groundwater quality. Dissolved oxygen, calcium, and sulfate concentrations and chloride:bromide ratios increased over time in one or more aquifers, while pH and concentrations of bromide and dissolved organic carbon decreased over time. Detections of total coliform bacteria and nitrate did not become more frequent from 1986 to 2009, even though potential sources of these constituents, such as number of septic systems (linked to population) and percent developed land in the county, increased during this period.
Rios, Rodrigo; Loomba, Rohit S; Foerster, Susan R; Pelech, Andrew N; Gudausky, Todd M
2016-04-01
Coronary allograft vasculopathy (CAV) is the leading cause of graft failure in pediatric heart transplant recipients, also adding to mortality in this patient population. Coronary angiography is routinely performed to screen for CAV, with conventional single-plane or bi-plane angiography being utilized. Dual-axis rotational coronary angiography (RA) has been described, mostly in the adult population, and may offer reduction in radiation dose and contrast volume. Experience with this in the pediatric population is limited. This study describes a single-institution experience with RA for screening for CAV in pediatric patients. The catheterization database at our institution was used to identify pediatric heart transplant recipients having undergone RA to screen for CAV. Procedural data including radiation dose, fluoroscopy time, contrast volume, and procedure time were collected for each catheterization. The number of instances in which RA was not successful, ECG changes were present, and CAV was detected were also collected for each catheterization. A total of 97 patients underwent 345 catheterizations utilizing RA. Median radiation dose-area product per kilogram was found to be 341.7 (mGy cm(2)/kg), total air kerma was 126.8 (mGy), procedure time was 69 min, fluoroscopy time was 9.9 min, and contrast volume was 13 ml. A total of 17 (2 %) coronary artery injections out of 690 could not be successfully imaged using RA. A total of 14 patients had CAV noted at any point, 10 of whom had progressive CAV. Electrocardiographic changes were documented in a total of 10 (3 %) RA catheterizations. Procedural characteristics did not differ between serial catheterizations. RA is safe and feasible for CAV screening in pediatric heart transplant recipients while offering coronary imaging in multiple planes compared to conventional angiography.
NASA Technical Reports Server (NTRS)
Sharp, D.; Williams, E.; Weber, M.; Goodman, Steven J.; Raghavan, R.; Matlin, A.; Boldi, B.
1998-01-01
This paper will discuss findings of a collaborative lightning research project between National Aeronautics and Space Administration, the Massachusetts Institute of Technology and the National Weather Service office In Melbourne Florida. In August 1996, NWS/MLB received a workstation which incorporates data from the KMLB WSR-88D, Cloud to Ground (CG) stroke data from the National Lightning Detection Network (NLDN), and 3D volumetric lightning data collected from the Kennedy Space Centers' Lightning Detection And Ranging (LDAR) lightning system. The two primary objectives of this lightning workstation, called Lightning Imaging Sensor Data Applications Display (USDAD), are to: observe how total lightning relates to severe convective storm morphology over central Florida, and compare ground based total lightning data (LDAR) to a satellite based lightning detection system. This presentation will focus on objective #1. The LISDAD system continuously displays CG and total lighting activity overlaid on top of the KMLB composite reflectivity product. This allows forecasters to monitor total lightning activity associated with convective cells occurring over the central Florida peninsula and adjacent coastal waters. The LISDAD system also keeps track of the amount of total lightning data, and associated KMLB radar products with individual convective cells occurring over the region. By clicking on an individual cell, a history table displays flash rate information (CG and total lightning) in one minute increments, along with radar parameter trends (echo tops, maximum dBz and height of maximum dBz) every 5 minutes. This history table Is updated continuously, without user intervention, as long as the cell is identified. Reviewing data collected during the 1997 wet season (21 cases) revealed that storms which produced severe weather (hall greater or = 0.75 in. or wind damage) typically showed a rapid rise In total lightning prior to the onset of severe weather. On average, flash rate increases of 25 FPM per minute over a time scale of approximately 5 minutes were common. These pulse severe storms typically reached values of 150 to 200 FPM with some cells exceeding 400 FPM. One finding which could have a direct application to the warning process is that the rapid increase in lightning typically occurred in advance of the warning issuance time. Comparisons between the ending time of the rapid rate increase and the time of when the warning was issued by NWS/MLB meteorologist exhibited a lead time of 8 minutes. It is conceivable that if close monitoring of the LISDAD system by operational meteorologist is routinely performed, warnings for pulse severe storms could be issued up to 4 to 6 minutes earlier than what is issued currently.
Role of sleep continuity and total sleep time in executive function across the adult lifespan.
Wilckens, Kristine A; Woo, Sarah G; Kirk, Afton R; Erickson, Kirk I; Wheeler, Mark E
2014-09-01
The importance of sleep for cognition in young adults is well established, but the role of habitual sleep behavior in cognition across the adult life span remains unknown. We examined the relationship between sleep continuity and total sleep time as assessed with a sleep-detection device, and cognitive performance using a battery of tasks in young (n = 59, mean age = 23.05) and older (n = 53, mean age = 62.68) adults. Across age groups, higher sleep continuity was associated with better cognitive performance. In the younger group, higher sleep continuity was associated with better working memory and inhibitory control. In the older group, higher sleep continuity was associated with better inhibitory control, memory recall, and verbal fluency. Very short and very long total sleep time was associated with poorer working memory and verbal fluency, specifically in the younger group. Total sleep time was not associated with cognitive performance in any domains for the older group. These findings reveal that sleep continuity is important for executive function in both young and older adults, but total sleep time may be more important for cognition in young adults. PsycINFO Database Record (c) 2014 APA, all rights reserved.
Convolution neural networks for real-time needle detection and localization in 2D ultrasound.
Mwikirize, Cosmas; Nosher, John L; Hacihaliloglu, Ilker
2018-05-01
We propose a framework for automatic and accurate detection of steeply inserted needles in 2D ultrasound data using convolution neural networks. We demonstrate its application in needle trajectory estimation and tip localization. Our approach consists of a unified network, comprising a fully convolutional network (FCN) and a fast region-based convolutional neural network (R-CNN). The FCN proposes candidate regions, which are then fed to a fast R-CNN for finer needle detection. We leverage a transfer learning paradigm, where the network weights are initialized by training with non-medical images, and fine-tuned with ex vivo ultrasound scans collected during insertion of a 17G epidural needle into freshly excised porcine and bovine tissue at depth settings up to 9 cm and [Formula: see text]-[Formula: see text] insertion angles. Needle detection results are used to accurately estimate needle trajectory from intensity invariant needle features and perform needle tip localization from an intensity search along the needle trajectory. Our needle detection model was trained and validated on 2500 ex vivo ultrasound scans. The detection system has a frame rate of 25 fps on a GPU and achieves 99.6% precision, 99.78% recall rate and an [Formula: see text] score of 0.99. Validation for needle localization was performed on 400 scans collected using a different imaging platform, over a bovine/porcine lumbosacral spine phantom. Shaft localization error of [Formula: see text], tip localization error of [Formula: see text] mm, and a total processing time of 0.58 s were achieved. The proposed method is fully automatic and provides robust needle localization results in challenging scanning conditions. The accurate and robust results coupled with real-time detection and sub-second total processing make the proposed method promising in applications for needle detection and localization during challenging minimally invasive ultrasound-guided procedures.
NASA Technical Reports Server (NTRS)
Lala, J. H.; Smith, T. B., III
1983-01-01
The experimental test and evaluation of the Fault-Tolerant Multiprocessor (FTMP) is described. Major objectives of this exercise include expanding validation envelope, building confidence in the system, revealing any weaknesses in the architectural concepts and in their execution in hardware and software, and in general, stressing the hardware and software. To this end, pin-level faults were injected into one LRU of the FTMP and the FTMP response was measured in terms of fault detection, isolation, and recovery times. A total of 21,055 stuck-at-0, stuck-at-1 and invert-signal faults were injected in the CPU, memory, bus interface circuits, Bus Guardian Units, and voters and error latches. Of these, 17,418 were detected. At least 80 percent of undetected faults are estimated to be on unused pins. The multiprocessor identified all detected faults correctly and recovered successfully in each case. Total recovery time for all faults averaged a little over one second. This can be reduced to half a second by including appropriate self-tests.
Petrova, E R; Sukhovetskaia, V P; Pisareva, M M; Maiorova, V G; Sverlova, M V; Danilenko, D M; Petrova, P A; Krivitskaia, V Z; Sominina, A A
2015-11-01
The analysis was implemented concerning diagnostic parameters of commercial quick tests (immune chromatographic tests BinaxNOW Influenza A&B and BinaxNow RSV Alere, Scarborough Inc., USA) under detection of antigens of influenza virus A and respiratory syncytial virus in clinical materials. The polymerase chain reaction in real-time and isolation ofviruses in cell cultures. The analysis of naso-pharyngeal smears from 116 children demonstrated that sensitivity and specifcity of detection of influenza virus A using device mariPOC in comparison with polymerase chain reaction made up to 93.8% and 99.0% correspondingly at total concordance of results of both techniques as 98.3%. At diagnosing of respiratory syncytial virus using device mariPOC parameters made up to 77.3%, 98.9% and 862% as compared with polymerase chain reaction. The sensitivity, specificity and total concordance of results of immune chromatographic tests BinaxNOW in comparison ofpolymerase chain reaction made up to 86.7%, 100% and 96.2% correspondingly at detection of influenza virus A and 80.9%, 97.4% and 91.6% correspondingly at detection of respiratory syncytial virus. In comparison with isolation technique in cell cultures sensitivity of system mariPOC and immune chromatographic tests proved to be in 1.3-1.4 times higher at detection of influenza virus A and in 1.7-2 times higher in case of isolation of respiratory syncytial virus. There is no statistically significant differences between diagnostic parameters received for mariPOC and immune chromatographic tests at diagnosing influenza virus A and respiratory syncytial viral infection.
Ma, Y; Dai, X; Hong, T; Munk, G B; Libera, M
2016-12-19
Despite their many advantages and successes, molecular beacon (MB) hybridization probes have not been extensively used in microarray formats because of the complicating probe-substrate interactions that increase the background intensity. We have previously shown that tethering to surface-patterned microgels is an effective means for localizing MB probes to specific surface locations in a microarray format while simultaneously maintaining them in as water-like an environment as possible and minimizing probe-surface interactions. Here we extend this approach to include both real-time detection together with integrated NASBA amplification. We fabricate small (∼250 μm × 250 μm) simplex, duplex, and five-plex assays with microarray spots of controllable size (∼20 μm diameter), position, and shape to detect bacteria and fungi in a bloodstream-infection model. The targets, primers, and microgel-tethered probes can be combined in a single isothermal reaction chamber with no post-amplification labelling. We extract total RNA from clinical blood samples and differentiate between Gram-positive and Gram-negative bloodstream infection in a duplex assay to detect RNA- amplicons. The sensitivity based on our current protocols in a simplex assay to detect specific ribosomal RNA sequences within total RNA extracted from S. aureus and E. coli cultures corresponds to tens of bacteria per ml. We furthermore show that the platform can detect RNA- amplicons from synthetic target DNA with 1 fM sensitivity in sample volumes that contain about 12 000 DNA molecules. These experiments demonstrate an alternative approach that can enable rapid and real-time microarray-based molecular diagnostics.
Neutron camera employing row and column summations
Clonts, Lloyd G.; Diawara, Yacouba; Donahue, Jr, Cornelius; Montcalm, Christopher A.; Riedel, Richard A.; Visscher, Theodore
2016-06-14
For each photomultiplier tube in an Anger camera, an R.times.S array of preamplifiers is provided to detect electrons generated within the photomultiplier tube. The outputs of the preamplifiers are digitized to measure the magnitude of the signals from each preamplifier. For each photomultiplier tube, a corresponding summation circuitry including R row summation circuits and S column summation circuits numerically add the magnitudes of the signals from preamplifiers for each row and for each column to generate histograms. For a P.times.Q array of photomultiplier tubes, P.times.Q summation circuitries generate P.times.Q row histograms including R entries and P.times.Q column histograms including S entries. The total set of histograms include P.times.Q.times.(R+S) entries, which can be analyzed by a position calculation circuit to determine the locations of events (detection of a neutron).
Sensitivity of Small RNA-Based Detection of Plant Viruses.
Santala, Johanna; Valkonen, Jari P T
2018-01-01
Plants recognize unrelated viruses by the antiviral defense system called RNA interference (RNAi). RNAi processes double-stranded viral RNA into small RNAs (sRNAs) of 21-24 nucleotides, the reassembly of which into longer strands in silico allows virus identification by comparison with the sequences available in databases. The aim of this study was to compare the virus detection sensitivity of sRNA-based virus diagnosis with the established virus species-specific polymerase chain reaction (PCR) approach. Viruses propagated in tobacco plants included three engineered, infectious clones of Potato virus A (PVA), each carrying a different marker gene, and an infectious clone of Potato virus Y (PVY). Total RNA (containing sRNA) was isolated and subjected to reverse-transcription real-time PCR (RT-RT-PCR) and sRNA deep-sequencing at different concentrations. RNA extracted from various crop plants was included in the reactions to normalize RNA concentrations. Targeted detection of selected viruses showed a similar threshold for the sRNA and reverse-transcription quantitative PCR (RT-qPCR) analyses. The detection limit for PVY and PVA by RT-qPCR in this study was 3 and 1.5 fg of viral RNA, respectively, in 50 ng of total RNA per PCR reaction. When knowledge was available about the viruses likely present in the samples, sRNA-based virus detection was 10 times more sensitive than RT-RT-PCR. The advantage of sRNA analysis is the detection of all tested viruses without the need for virus-specific primers or probes.
Jahan, Munira; Lutful Moben, Ahmed; Tabassum, Shahina
2014-01-01
ABSTRACT Background Both real-time-polymerase chain reaction (PCR) and hybrid capture 2 (HC2) assay can detect and quantify hepatitis B virus (HBV) DNA. However, real-time-PCR can detect a wide range of HBV DNA, while HC2 assay could not detect lower levels of viremia. The present study was designed to detect and quantify HBV DNA by real-time-PCR and HC2 assay and compare the quantitative data of these two assays. Materials and methods A cross-sectional study was conducted in between July 2010 and June 2011. A total of 66 serologically diagnosed chronic hepatitis B (CHB) patients were selected for the study. Real-time-PCR and HC2 assay was done to detect HBV DNA. Data were analyzed by statistical Package for the social sciences (SPSS). Results Among 66 serologically diagnosed chronic hepatitis B patients 40 (60.61%) patients had detectable and 26 (39.39%) had undetectable HBV DNA by HC2 assay. Concordant results were obtained for 40 (60.61%) out of these 66 patients by real-time-PCR and HC2 assay with mean viral load of 7.06 ± 1.13 log10 copies/ml and 6.95 ± 1.08 log10 copies/ml, respectively. In the remaining 26 patients, HBV DNA was detectable by real-time-PCR in 20 patients (mean HBV DNA level was 3.67 ± 0.72 log10 copies/ml. However, HBV DNA could not be detectable in six cases by the both assays. The study showed strong correlation (r = 0.915) between real-time-PCR and HC2 assay for the detection and quantification of HBV DNA. Conclusion HC2 assay may be used as an alternative to real-time-PCR for CHB patients. How to cite this article: Majid F, Jahan M, Moben AL, Tabassum S. Comparison of Hybrid Capture 2 Assay with Real-time-PCR for Detection and Quantitation of Hepatitis B Virus DNA. Euroasian J Hepato-Gastroenterol 2014;4(1):31-35. PMID:29264316
Towards a Low-Cost Remote Memory Attestation for the Smart Grid
Yang, Xinyu; He, Xiaofei; Yu, Wei; Lin, Jie; Li, Rui; Yang, Qingyu; Song, Houbing
2015-01-01
In the smart grid, measurement devices may be compromised by adversaries, and their operations could be disrupted by attacks. A number of schemes to efficiently and accurately detect these compromised devices remotely have been proposed. Nonetheless, most of the existing schemes detecting compromised devices depend on the incremental response time in the attestation process, which are sensitive to data transmission delay and lead to high computation and network overhead. To address the issue, in this paper, we propose a low-cost remote memory attestation scheme (LRMA), which can efficiently and accurately detect compromised smart meters considering real-time network delay and achieve low computation and network overhead. In LRMA, the impact of real-time network delay on detecting compromised nodes can be eliminated via investigating the time differences reported from relay nodes. Furthermore, the attestation frequency in LRMA is dynamically adjusted with the compromised probability of each node, and then, the total number of attestations could be reduced while low computation and network overhead can be achieved. Through a combination of extensive theoretical analysis and evaluations, our data demonstrate that our proposed scheme can achieve better detection capacity and lower computation and network overhead in comparison to existing schemes. PMID:26307998
Towards a Low-Cost Remote Memory Attestation for the Smart Grid.
Yang, Xinyu; He, Xiaofei; Yu, Wei; Lin, Jie; Li, Rui; Yang, Qingyu; Song, Houbing
2015-08-21
In the smart grid, measurement devices may be compromised by adversaries, and their operations could be disrupted by attacks. A number of schemes to efficiently and accurately detect these compromised devices remotely have been proposed. Nonetheless, most of the existing schemes detecting compromised devices depend on the incremental response time in the attestation process, which are sensitive to data transmission delay and lead to high computation and network overhead. To address the issue, in this paper, we propose a low-cost remote memory attestation scheme (LRMA), which can efficiently and accurately detect compromised smart meters considering real-time network delay and achieve low computation and network overhead. In LRMA, the impact of real-time network delay on detecting compromised nodes can be eliminated via investigating the time differences reported from relay nodes. Furthermore, the attestation frequency in LRMA is dynamically adjusted with the compromised probability of each node, and then, the total number of attestations could be reduced while low computation and network overhead can be achieved. Through a combination of extensive theoretical analysis and evaluations, our data demonstrate that our proposed scheme can achieve better detection capacity and lower computation and network overhead in comparison to existing schemes.
Yang, Yang; Qin, Xiaodong; Zhang, Wei; Li, Yanmin; Zhang, Zhidong
2016-10-01
Porcine parvovirus (PPV) is a major cause of swine reproductive failure and reported in many countries worldwide. Recombinase polymerase amplification (RPA) assays using a real-time fluorescent detection (PPV real-time RPA assay) and a lateral flow dipstick (PPV RPA LFD assay) were developed targeting PPV NS1 gene. The detection limit of PPV real-time RPA assay was 300 copies per reaction within 9 min at 38 °C, while the RPA LFD assay has a detection limit of 400 copies per reaction in less than 20 min at 38 °C. In both assays, there were no cross-reactions with porcine circovirus type 2, pseudorabies virus, porcine reproductive and respiratory syndrome virus, classical swine fever virus, and foot-and-mouth disease virus. Based on a total of 128 clinical samples examined, the sensitivity and the specificity of the developed RPA assays for identification of PPV was 94.4% and 100%, respectively, when compared to real-time (qPCR) assay. Therefore, the RPA assay provides a rapid, sensitive and specific alternative for PPV detection. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Chevalier, Pascal; Oukaci, Abdelkader; Delmas, Jean-Pierre
2011-12-01
The detection of a known signal with unknown parameters in the presence of noise plus interferences (called total noise) whose covariance matrix is unknown is an important problem which has received much attention these last decades for applications such as radar, satellite localization or time acquisition in radio communications. However, most of the available receivers assume a second order (SO) circular (or proper) total noise and become suboptimal in the presence of SO noncircular (or improper) interferences, potentially present in the previous applications. The scarce available receivers which take the potential SO noncircularity of the total noise into account have been developed under the restrictive condition of a known signal with known parameters or under the assumption of a random signal. For this reason, following a generalized likelihood ratio test (GLRT) approach, the purpose of this paper is to introduce and to analyze the performance of different array receivers for the detection of a known signal, with different sets of unknown parameters, corrupted by an unknown noncircular total noise. To simplify the study, we limit the analysis to rectilinear known useful signals for which the baseband signal is real, which concerns many applications.
X-ray detection capability of a BaCl{sub 2} single crystal scintillator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koshimizu, Masanori; CREST, Japan Science and Technology Agency, Sanbancho, Chiyoda-ku, Tokyo 102-0075; Onodera, Kazuya
2012-01-15
The x-ray detection capability of a scintillation detector equipped with a BaCl{sub 2} single crystal was evaluated. The scintillation decay kinetics can be expressed by a sum of two exponential decay components. The fast and slow components have lifetimes of 1.5 and 85 ns, respectively. The total light output is 5% that of YAP:Ce. A subnanosecond timing resolution was obtained. The detection efficiency of a 67.41 keV x-ray is 87% for a detector equipped with a BaCl{sub 2} crystal 6-mm thick. Thus, excellent timing resolution and high detection efficiency can be simultaneously achieved. Additionally, luminescence decay characteristics under vacuum ultravioletmore » excitation have been investigated. Radiative decay of self-trapped excitons is thought to be responsible for the fast scintillation component.« less
NBC detection in air and water
NASA Technical Reports Server (NTRS)
Hartley, Frank T.; Smith, Steven J.; McMurtry, Gary M.
2003-01-01
Participating in a Navy STTR project to develop a system capable of the 'real-time' detection and quanitification of nuclear, biological and chemical (NBC) warfare agents, and of related industrial chemicals including NBC agent synthesis by-products in water and in air immediately above the water's surface. This project uses JPL's Soft Ionization Membrane (SIM) technology which totally ionizes molecules without fragmentation (a process that can markedly improve the sensitivity and specificity of molecule compostition identification), and JPL's Rotating Field Mass Spectrometer (RFMS) technology which has large enough dynamic mass range to enable detection of nuclear materials as well as biological and chemical agents. This Navy project integrates these JPL Environmental Monitoring UnitS (REMUS) an autonomous underwater vehicle (AUV). It is anticipated that the REMUS AUV will be capable of 'real-time' detection and quantification of NBC warefare agents.
Detecting Industrial Pollution in the Atmospheres of Earth-like Exoplanets
NASA Astrophysics Data System (ADS)
Lin, Henry W.; Gonzalez Abad, Gonzalo; Loeb, Abraham
2014-09-01
Detecting biosignatures, such as molecular oxygen in combination with a reducing gas, in the atmospheres of transiting exoplanets has been a major focus in the search for alien life. We point out that in addition to these generic indicators, anthropogenic pollution could be used as a novel biosignature for intelligent life. To this end, we identify pollutants in the Earth's atmosphere that have significant absorption features in the spectral range covered by the James Webb Space Telescope. We focus on tetrafluoromethane (CF4) and trichlorofluoromethane (CCl3F), which are the easiest to detect chlorofluorocarbons (CFCs) produced by anthropogenic activity. We estimate that ~1.2 days (~1.7 days) of total integration time will be sufficient to detect or constrain the concentration of CCl3F (CF4) to ~10 times the current terrestrial level.
Detection of a stellar flare at extreme ultraviolet wavelengths
NASA Technical Reports Server (NTRS)
Barstow, M. A.; Denby, M.; Pye, J. P.; Pankiewicz, G. S.; Bromage, G. E.; Gonzalez-Riestra, R.
1991-01-01
During the all-sky survey conducted by the Rosat Wide Field Camera, the binary flare star system BY Draconis was monitored with coverage by the IUE satellite far-UV and optical observations and by the Rosat X-ray telescope for part of the time. A stellar flare was detected in all four wavebands. This is the first unambiguous EUV detection of a flare and one of the widest simultaneous wavelength-range coverages obtained. The peak luminosity and total energy of this flare in the photon energy range 0.08-0.18 keV are comparable with the values obtained for a number of flares integrated over a larger energy range by Exosat satellite observations in 1983-86. It is concluded that radiation in the EUV carries away a substantial fraction of the total flare energy.
Syndromic surveillance for health information system failures: a feasibility study
Ong, Mei-Sing; Magrabi, Farah; Coiera, Enrico
2013-01-01
Objective To explore the applicability of a syndromic surveillance method to the early detection of health information technology (HIT) system failures. Methods A syndromic surveillance system was developed to monitor a laboratory information system at a tertiary hospital. Four indices were monitored: (1) total laboratory records being created; (2) total records with missing results; (3) average serum potassium results; and (4) total duplicated tests on a patient. The goal was to detect HIT system failures causing: data loss at the record level; data loss at the field level; erroneous data; and unintended duplication of data. Time-series models of the indices were constructed, and statistical process control charts were used to detect unexpected behaviors. The ability of the models to detect HIT system failures was evaluated using simulated failures, each lasting for 24 h, with error rates ranging from 1% to 35%. Results In detecting data loss at the record level, the model achieved a sensitivity of 0.26 when the simulated error rate was 1%, while maintaining a specificity of 0.98. Detection performance improved with increasing error rates, achieving a perfect sensitivity when the error rate was 35%. In the detection of missing results, erroneous serum potassium results and unintended repetition of tests, perfect sensitivity was attained when the error rate was as small as 5%. Decreasing the error rate to 1% resulted in a drop in sensitivity to 0.65–0.85. Conclusions Syndromic surveillance methods can potentially be applied to monitor HIT systems, to facilitate the early detection of failures. PMID:23184193
Caldwell, Andral W.; Falls, W. Fred; Guimaraes, Wladmir B.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.
2011-01-01
Soil gas and soil were assessed for contaminants at the Old Metal Workshop Hog Farm Area at Fort Gordon, Georgia, from October 2009 to September 2010. The assessment included delineating organic contaminants present in soil-gas and inorganic contaminants present in soil samples collected from the area estimated to be the Old Metal Workshop Hog Farm Area. This assessment was conducted to provide environmental contamination data to Fort Gordon personnel pursuant to requirements for the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. All soil-gas samplers contained total petroleum hydrocarbons above the method detection level. The highest total petroleum hydrocarbon mass detected was 121.32 micrograms in a soil-gas sampler from the western corner of the Old Metal Workshop Hog Farm Area along Sawmill Road. The highest undecane mass detected was 73.28 micrograms at the same location as the highest total petroleum hydrocarbon mass. Some soil-gas samplers detected toluene mass greater than the method detection level of 0.02 microgram; the highest detection of toluene mass was 0.07 microgram. Some soil-gas samplers were installed in areas of high-contaminant mass to assess for explosives and chemical agents. Explosives or chemical agents were not detected above their respective method detection levels for all soil-gas samplers installed. Inorganic concentrations in five soil samples collected did not exceed regional screening levels established by the U.S. Environmental Protection Agency. Barium concentrations, however, were up to eight times higher than the background concentrations reported in similar Coastal Plain sediments of South Carolina.
Kim, Min-Young; Seguin, Philippe; Ahn, Joung-Kuk; Kim, Jong-Jin; Chun, Se-Chul; Kim, Eun-Hye; Seo, Su-Hyun; Kang, Eun-Young; Kim, Sun-Lim; Park, Yool-Jin; Ro, Hee-Myong; Chung, Ill-Min
2008-08-27
A study was conducted to determine the content of phenolic compounds and the antioxidative activity of five edible and five medicinal mushrooms commonly cultivated in Korea. Phenolic compounds were analyzed using high performance liquid chromatography, and antioxidant activity was evaluated by 1,1-diphenyl-2-picrylhydrazyl radical scavenging activity and superoxide dismutase activity. A total of 28 phenolic compounds were detected in the mushrooms studied. The average total concentration of phenolic compounds was 326 microg/g, the average being of 174 microg/g in edible mushrooms and 477 microg/g in medicinal mushrooms. The average total flavonoids concentration was 49 microg/g, with averages of 22 and 76 microg/g in edible and medicinal mushrooms, respectively. The DPPH radical scavenging activities ranged between 15 (Pleurotus eryngii) and 70% (Ganoderma lucidum) when reaction time was for 1 min. When reaction time was 30 min, the values ranged between 5 (Pleurotus eryngii) and 78% (Agaricus bisporus). The SOD activity averaged 28% among the 10 mushroom species, averages for edible and medicinal mushrooms being comparable. DPPH activities was significantly correlated (p < 0.01) with total content of phenolic compounds in edible mushrooms, while in medicinal mushrooms there was a significant correlation (p < 0.01) between SOD activity and total concentration of phenolic compounds. Numerous significant positive correlations were observed between phenolic compounds detected and antioxidative potential.
López-Calleja, Inés María; de la Cruz, Silvia; González, Isabel; García, Teresa; Martín, Rosario
2015-06-15
Two real-time polymerase chain reaction (PCR)-based assays for detection of walnut (Juglans regia) and pecan (Carya illinoinensis) traces in a wide range of processed foods are described here. The method consists on a real-time PCR assay targeting the ITS1 region, using a nuclease (TaqMan) probe labeled with FAM and BBQ. The method was positive for walnut and pecan respectively, and negative for all other heterologous plants and animals tested. Using a series of model samples with defined raw walnut in wheat flour and heat-treated walnut in wheat flour with a range of concentrations of 0.1-100,000 mg kg(-1), a practical detection limit of 0.1 mg kg(-1) of walnut content was estimated. Identical binary mixtures were done for pecan, reaching the same limit of detection of 0.1 mg kg(-1). The assay was successfully trialed on a total of 232 commercial foodstuffs. Copyright © 2015 Elsevier Ltd. All rights reserved.
Real-time detection of hazardous materials in air
NASA Astrophysics Data System (ADS)
Schechter, Israel; Schroeder, Hartmut; Kompa, Karl L.
1994-03-01
A new detection system has been developed for real-time analysis of organic compounds in ambient air. It is based on multiphoton ionization by an unfocused laser beam in a single parallel-plate device. Thus, the ionization volume can be relatively large. The amount of laser created ions is determined quantitatively from the induced total voltage drop between the biased plates (Q equals (Delta) V(DOT)C). Mass information is obtained from computer analysis of the time-dependent signal. When a KrF laser (5 ev) is used, most of the organic compounds can be ionized in a two-photon process, but none of the standard components of atmospheric air are ionized by this process. Therefore, this instrument may be developed as a `sniffer' for organic materials. The method has been applied for benzene analysis in air. The detection limit is about 10 ppb. With a simple preconcentration technique the detection limit can be decreased to the sub-ppb range. Simple binary mixtures are also resolved.
INTEGRAL detection of hard X-ray emission from NGC 1566
NASA Astrophysics Data System (ADS)
Ducci, L.; Siegert, T.; Diehl, R.; Sanchez-Fernandez, C.; Ferrigno, C.; Savchenko, V.; Bozzo, E.
2018-06-01
During the observations of the Reticulum II region carried out from 2018 June 12 to 2018 June 19 (total exposure time of 208 ks), the IBIS/ISGRI instrument on board INTEGRAL detected significant hard X-ray emission from a source with coordinates: RA: 4:19:49 Dec: -54:56:28, with 3.5 arcmin 90% confinement radius and spatially coincident with the Seyfert galaxy NGC 1566.
Gonzalez, Aroa Garcia; Taraba, Lukáš; Hraníček, Jakub; Kozlík, Petr; Coufal, Pavel
2017-01-01
Dasatinib is a novel oral prescription drug proposed for treating adult patients with chronic myeloid leukemia. Three analytical methods, namely ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis, were developed, validated, and compared for determination of the drug in the tablet dosage form. The total analysis time of optimized ultra high performance liquid chromatography and capillary zone electrophoresis methods was 2.0 and 2.2 min, respectively. Direct ultraviolet detection with detection wavelength of 322 nm was employed in both cases. The optimized sequential injection analysis method was based on spectrophotometric detection of dasatinib after a simple colorimetric reaction with folin ciocalteau reagent forming a blue-colored complex with an absorbance maximum at 745 nm. The total analysis time was 2.5 min. The ultra high performance liquid chromatography method provided the lowest detection and quantitation limits and the most precise and accurate results. All three newly developed methods were demonstrated to be specific, linear, sensitive, precise, and accurate, providing results satisfactorily meeting the requirements of the pharmaceutical industry, and can be employed for the routine determination of the active pharmaceutical ingredient in the tablet dosage form. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Detectability of galactic supernova neutrinos coherently scattered on xenon nuclei in XMASS
NASA Astrophysics Data System (ADS)
Abe, K.; Hiraide, K.; Ichimura, K.; Kishimoto, Y.; Kobayashi, K.; Kobayashi, M.; Moriyama, S.; Nakagawa, K.; Nakahata, M.; Norita, T.; Ogawa, H.; Sekiya, H.; Takachio, O.; Takeda, A.; Yamashita, M.; Yang, B. S.; Kim, N. Y.; Kim, Y. D.; Tasaka, S.; Liu, J.; Martens, K.; Suzuki, Y.; Fujita, R.; Hosokawa, K.; Miuchi, K.; Oka, N.; Onishi, Y.; Takeuchi, Y.; Kim, Y. H.; Lee, J. S.; Lee, K. B.; Lee, M. K.; Fukuda, Y.; Itow, Y.; Kegasa, R.; Kobayashi, K.; Masuda, K.; Takiya, H.; Uchida, H.; Nishijima, K.; Fujii, K.; Murayama, I.; Nakamura, S.; Xmass Collaboration
2017-03-01
The coherent elastic neutrino-nucleus scattering (CEvNS) plays a crucial role at the final evolution of stars. The detection of it would be of importance in astroparticle physics. Among all available neutrino sources, galactic supernovae give the highest neutrino flux in the MeV range. Among all liquid xenon dark matter experiments, XMASS has the largest sensitive volume and light yield. The possibility to detect galactic supernova via the CEvNS-process on xenon nuclei in the current XMASS detector was investigated. The total number of events integrated in about 18 s after the explosion of a supernova 10 kpc away from the Earth was expected to be from 3.5 to 21.1, depending on the supernova model used to predict the neutrino flux, while the number of background events in the same time window was measured to be negligible. All lead to very high possibility to detect CEvNS experimentally for the first time utilizing the combination of galactic supernovae and the XMASS detector. In case of a supernova explosion as close as Betelgeuse, the total observable events can be more than ∼ 104, making it possible to distinguish different supernova models by examining the evolution of neutrino event rate in XMASS.
NASA Astrophysics Data System (ADS)
Schaibley, J. R.; Burgers, A. P.; McCracken, G. A.; Steel, D. G.; Bracker, A. S.; Gammon, D.; Sham, L. J.
2013-03-01
Optical Rabi oscillations are coherent population oscillations of a two-level system coupled by an electric dipole transition when driven by a strong nearly resonant optical field. In quantum dot structures, these measurements have typically been performed as a function of the total pulse area ∫Ω0(t)dt where the pulse area varies as a function of Rabi frequency. Here, we report direct detection of the time-resolved coherent transient response of the resonance fluorescence to measure the time evolution of the optical Rabi oscillations in a single charged InAs quantum dot. We extract a decoherence rate consistent with the limit from the excited state lifetime.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peter W. Carr; K.M. Fuller; D.R. Stoll
A new approach has been developed by modifying a conventional gradient elution liquid chromatograph for the high throughput screening of biological samples to detect the presence of regulated intoxicants. The goal of this work was to improve the speed of a gradient elution screening method over current approaches by optimizing the operational parameters of both the column and the instrument without compromising the reproducibility of the retention times, which are the basis for the identification. Most importantly, the novel instrument configuration substantially reduces the time needed to re-equilibrate the column between gradient runs, thereby reducing the total time for eachmore » analysis. The total analysis time for each gradient elution run is only 2.8 minutes, including 0.3 minutes for column reequilibration between analyses. Retention times standard calibration solutes are reproducible to better than 0.002 minutes in consecutive runs. A corrected retention index was adopted to account for day-to-day and column-to-column variations in retention time. The discriminating power and mean list length were calculated for a library of 47 intoxicants and compared with previous work from other laboratories to evaluate fast gradient elution HPLC as a screening tool.« less
NuSTAR detects X-rays from a deeply embedded shock in the Fermi-detected nova ASASSN-18fv
NASA Astrophysics Data System (ADS)
Nelson, Thomas; Mukai, Koji; Sokoloski, J. L.; Metzger, Brian; Chomiuk, Laura; Linford, Justin; Vurm, Indrek
2018-05-01
In response to the detection of gamma-ray emission with the Fermi LAT instrument in the recent nova ASASSN-18fv (ATel #11546), we carried out a target-of-opportunity observation of the system with the NuSTAR observatory between 2018 April 20 and 2018 April 22. The total exposure time was 64 ks. A simultaneous soft X-ray observation was carried out using the Swift satellite at the end of the NuSTAR exposure on 2018 April 22, lasting 1000s.
Sensitivity of high-elevation streams in the Southern Blue Ridge Province to acidic deposition
Winger, P.V.; Lasier, P.J.; Hudy, M.; Fowler, D.; Van Den Avyle, M.J.
1987-01-01
The Southern Blue Ridge Province, which encompasses parts of northern Georgia, eastern Tennessee, and western North Carolina, has been predicted to be sensitive to impacts from acidic deposition, owing to the chemical composition of the bedrock geology and soils. This study confirms the predicted potential sensitivity, quantifies the level of total alkalinity and describes the chemical characteristics of 30 headwater streams of this area. Water chemistry was measured five times between April 1983 and June 1984 at first and third order reaches of each stream during baseflow conditions. Sensitivity based on total alkalinity and the Calcite Saturation Index indicates that the headwater streams of the Province are vulnerable to acidification. Total alkalinity and p11 were generally higher in third order reaches (mean, 72 ?eq/? and 6.7) than in first order reaches (64 ?eq/? and 6.4). Ionic concentrations were low, averaging 310 and 340 ?eq/? in first and third order reaches, respectively. A single sampling appears adequate for evaluating sensitivity based on total alkalinity, but large temporal variability requires multiple sampling for the detection of changes in pH and alkalinity over time. Monitoring of stream water should continue in order to detect any subtle effects of acidic deposition on these unique resource systems.
Todd Trench, Elaine C.
2004-01-01
A time-series analysis approach developed by the U.S. Geological Survey was used to analyze trends in total phosphorus and evaluate optimal sampling designs for future trend detection, using long-term data for two water-quality monitoring stations on the Quinebaug River in eastern Connecticut. Trend-analysis results for selected periods of record during 1971?2001 indicate that concentrations of total phosphorus in the Quinebaug River have varied over time, but have decreased significantly since the 1970s and 1980s. Total phosphorus concentrations at both stations increased in the late 1990s and early 2000s, but were still substantially lower than historical levels. Drainage areas for both stations are primarily forested, but water quality at both stations is affected by point discharges from municipal wastewater-treatment facilities. Various designs with sampling frequencies ranging from 4 to 11 samples per year were compared to the trend-detection power of the monthly (12-sample) design to determine the most efficient configuration of months to sample for a given annual sampling frequency. Results from this evaluation indicate that the current (2004) 8-sample schedule for the two Quinebaug stations, with monthly sampling from May to September and bimonthly sampling for the remainder of the year, is not the most efficient 8-sample design for future detection of trends in total phosphorus. Optimal sampling schedules for the two stations differ, but in both cases, trend-detection power generally is greater among 8-sample designs that include monthly sampling in fall and winter. Sampling designs with fewer than 8 samples per year generally provide a low level of probability for detection of trends in total phosphorus. Managers may determine an acceptable level of probability for trend detection within the context of the multiple objectives of the state?s water-quality management program and the scientific understanding of the watersheds in question. Managers may identify a threshold of probability for trend detection that is high enough to justify the agency?s investment in the water-quality sampling program. Results from an analysis of optimal sampling designs can provide an important component of information for the decision-making process in which sampling schedules are periodically reviewed and revised. Results from the study described in this report and previous studies indicate that optimal sampling schedules for trend detection may differ substantially for different stations and constituents. A more comprehensive statewide evaluation of sampling schedules for key stations and constituents could provide useful information for any redesign of the schedule for water-quality monitoring in the Quinebaug River Basin and elsewhere in the state.
NASA Technical Reports Server (NTRS)
Christian, Hugh
2003-01-01
Our knowledge of the global distribution of lightning has improved dramatically since the 1995 launch of the Optical Transient Detector (OTD) followed in 1997 by the launch of the Lightning Imaging Sensor (LIS). Together, these instruments have generated a continuous seven-year record of global lightning activity. These lightning observations have provided a new global perspective on total lightning activity. For the first time, total lightning activity (CG and IC) has been observed over large regions with high detection efficiencies and accurate geographic location. This has produced new insights into lightning distributions, times of occurrence and variability. It has produced a revised global flash rate estimate (46 flashes per second) and has lead to a new realization of the significance of total lightning activity in severe weather. Accurate flash rate estimates are now available for large areas of the earth (+/- 72deg latitude) Ocean-land contrasts as a function of season are clearly revealed, as are orographic effects and seasonal and interannual variability. The data set indicates that air mass thunderstorms, not large storm systems dominate global activity. The ability of LIS and OTD to detect total lightning has lead to improved insight into the correlation between lightning and storm development. The relationship between updraft development and lightning activity is now well established and presents an opportunity for providing a new mechanism for remotely monitoring storm development. In this concept, lightning would serve as a surrogate for updraft velocity. It is anticipated hat this capability could lead to significantly improved severe weather warning times and reduced false warning rates.
Xing, Jian; Burkom, Howard; Tokars, Jerome
2011-12-01
Automated surveillance systems require statistical methods to recognize increases in visit counts that might indicate an outbreak. In prior work we presented methods to enhance the sensitivity of C2, a commonly used time series method. In this study, we compared the enhanced C2 method with five regression models. We used emergency department chief complaint data from US CDC BioSense surveillance system, aggregated by city (total of 206 hospitals, 16 cities) during 5/2008-4/2009. Data for six syndromes (asthma, gastrointestinal, nausea and vomiting, rash, respiratory, and influenza-like illness) was used and was stratified by mean count (1-19, 20-49, ≥50 per day) into 14 syndrome-count categories. We compared the sensitivity for detecting single-day artificially-added increases in syndrome counts. Four modifications of the C2 time series method, and five regression models (two linear and three Poisson), were tested. A constant alert rate of 1% was used for all methods. Among the regression models tested, we found that a Poisson model controlling for the logarithm of total visits (i.e., visits both meeting and not meeting a syndrome definition), day of week, and 14-day time period was best. Among 14 syndrome-count categories, time series and regression methods produced approximately the same sensitivity (<5% difference) in 6; in six categories, the regression method had higher sensitivity (range 6-14% improvement), and in two categories the time series method had higher sensitivity. When automated data are aggregated to the city level, a Poisson regression model that controls for total visits produces the best overall sensitivity for detecting artificially added visit counts. This improvement was achieved without increasing the alert rate, which was held constant at 1% for all methods. These findings will improve our ability to detect outbreaks in automated surveillance system data. Published by Elsevier Inc.
Online particle detection with Neural Networks based on topological calorimetry information
NASA Astrophysics Data System (ADS)
Ciodaro, T.; Deva, D.; de Seixas, J. M.; Damazio, D.
2012-06-01
This paper presents the latest results from the Ringer algorithm, which is based on artificial neural networks for the electron identification at the online filtering system of the ATLAS particle detector, in the context of the LHC experiment at CERN. The algorithm performs topological feature extraction using the ATLAS calorimetry information (energy measurements). The extracted information is presented to a neural network classifier. Studies showed that the Ringer algorithm achieves high detection efficiency, while keeping the false alarm rate low. Optimizations, guided by detailed analysis, reduced the algorithm execution time by 59%. Also, the total memory necessary to store the Ringer algorithm information represents less than 6.2 percent of the total filtering system amount.
Real time in situ detection of organic nitrates in atmospheric aerosols
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rollins, Andrew W.; Smith, Jared D.; Wilson, Kevin R.
2010-06-11
A new field instrument is described that quantifies total particle phase organic nitrates. The instrument is based on the thermal dissociation laser induced fluorescence (TD-LIF) method that thermally converts nitrates to NO2 which is then detected by LIF. This instrument is unique in its ability to provide fast sensitive measurements of particle phase organic nitrates, without interference from inorganic nitrate. Here we use it to quantify organic nitrates in SOA generated from high-NOx photooxidation of limonene, a-pinene, D-3-carene, and tridecane. In these experiments the organic nitrate moiety is observed to be 6-15percent of the total SOA mass, depending on themore » organic precursor.« less
Multicutter machining of compound parametric surfaces
NASA Astrophysics Data System (ADS)
Hatna, Abdelmadjid; Grieve, R. J.; Broomhead, P.
2000-10-01
Parametric free forms are used in industries as disparate as footwear, toys, sporting goods, ceramics, digital content creation, and conceptual design. Optimizing tool path patterns and minimizing the total machining time is a primordial issue in numerically controlled (NC) machining of free form surfaces. We demonstrate in the present work that multi-cutter machining can achieve as much as 60% reduction in total machining time for compound sculptured surfaces. The given approach is based upon the pre-processing as opposed to the usual post-processing of surfaces for the detection and removal of interference followed by precise tracking of unmachined areas.
NASA Astrophysics Data System (ADS)
Bohlin, Alexis; Patterson, Brian D.; Kliewer, Christopher J.
2017-11-01
In many fields of study, from coherent Raman microscopy on living cells to time-resolved coherent Raman spectroscopy of gas-phase turbulence and combustion reaction dynamics, the need for the capability to time-resolve fast dynamical and nonrepetitive processes has led to the continued development of high-speed coherent Raman methods and new high-repetition rate laser sources, such as pulse-burst laser systems. However, much less emphasis has been placed on our ability to detect shot to shot coherent Raman spectra at equivalently high scan rates, across the kilohertz to megahertz regime. This is beyond the capability of modern scientific charge coupled device (CCD) cameras, for instance, as would be employed with a Czerny-Turner type spectrograph. As an alternative detection strategy with megahertz spectral detection rate, we demonstrate dispersive Fourier transformation detection of pulsed (∼90 ps) coherent Raman signals in the time-domain. Instead of reading the frequency domain signal out using a spectrometer and CCD, the signal is transformed into a time-domain waveform through dispersive Fourier transformation in a long single-mode fiber and read-out with a fast sampling photodiode and oscilloscope. Molecular O- and S-branch rotational sideband spectra from both N2 and H2 were acquired employing this scheme, and the waveform is fitted to show highly quantitative agreement with a molecular model. The total detection time for the rotational spectrum was 20 ns, indicating an upper limit to the detection frequency of ∼50 MHz, significantly faster than any other reported spectrally-resolved coherent anti-Stokes Raman detection strategy to date.
Sentinel lymph node detection in patients with endometrial cancer.
Niikura, Hitoshi; Okamura, Chikako; Utsunomiya, Hiroki; Yoshinaga, Kosuke; Akahira, Junichi; Ito, Kiyoshi; Yaegashi, Nobuo
2004-02-01
The purpose of this study was to examine the feasibility of sentinel lymph node (SLN) detection in patients with endometrial cancer using preoperative lymphoscintigraphy and an intraoperative gamma probe. Between June 2001 and January 2003, 28 consecutive patients with endometrial cancer who were scheduled for total abdominal hysterectomy, bilateral salpingo-oophorectomy, total pelvic lymphadenectomy, and paraaortic lymphadenectomy at Tohoku University School of Medicine underwent sentinel lymph node detection. On the day before surgery, preoperative lymphoscintigraphy was performed by injection of 99m-Technetium ((99m)Tc)-labeled phytate into the endometrium during hysteroscopy. At the time of surgery, a gamma-detecting probe was used to locate radioactive lymph nodes. At least one sentinel node was detected in each of 23 of the 28 patients (82%). The mean number of sentinel nodes detected was 3.1 (range, 1-9). Sentinel nodes could be identified in 21 of 22 patients (95%) whose tumor did not invade more than halfway into the myometrium. Eighteen patients had radioactive nodes in the paraaortic area. Most patients had a sentinel node in one of the following three sites: paraaortic, external iliac, and obturator. The sensitivity and specificity for detecting lymph node metastases were both 100%. The combination of preoperative lymphoscintigraphy with intraoperative gamma probe detection may be useful in identifying sentinel nodes in early-stage endometrial cancer.
Real-time Flare Detection in Ground-Based Hα Imaging at Kanzelhöhe Observatory
NASA Astrophysics Data System (ADS)
Pötzi, W.; Veronig, A. M.; Riegler, G.; Amerstorfer, U.; Pock, T.; Temmer, M.; Polanec, W.; Baumgartner, D. J.
2015-03-01
Kanzelhöhe Observatory (KSO) regularly performs high-cadence full-disk imaging of the solar chromosphere in the Hα and Ca ii K spectral lines as well as in the solar photosphere in white light. In the frame of ESA's (European Space Agency) Space Situational Awareness (SSA) program, a new system for real-time Hα data provision and automatic flare detection was developed at KSO. The data and events detected are published in near real-time at ESA's SSA Space Weather portal (http://swe.ssa.esa.int/web/guest/kso-federated). In this article, we describe the Hα instrument, the image-recognition algorithms we developed, and the implementation into the KSO Hα observing system. We also present the evaluation results of the real-time data provision and flare detection for a period of five months. The Hα data provision worked in 99.96 % of the images, with a mean time lag of four seconds between image recording and online provision. Within the given criteria for the automatic image-recognition system (at least three Hα images are needed for a positive detection), all flares with an area ≥ 50 micro-hemispheres that were located within 60° of the solar center and occurred during the KSO observing times were detected, a number of 87 events in total. The automatically determined flare importance and brightness classes were correct in ˜ 85 %. The mean flare positions in heliographic longitude and latitude were correct to within ˜ 1°. The median of the absolute differences for the flare start and peak times from the automatic detections in comparison with the official NOAA (and KSO) visual flare reports were 3 min (1 min).
Létant, Sonia E; Murphy, Gloria A; Alfaro, Teneile M; Avila, Julie R; Kane, Staci R; Raber, Ellen; Bunt, Thomas M; Shah, Sanjiv R
2011-09-01
In the event of a biothreat agent release, hundreds of samples would need to be rapidly processed to characterize the extent of contamination and determine the efficacy of remediation activities. Current biological agent identification and viability determination methods are both labor- and time-intensive such that turnaround time for confirmed results is typically several days. In order to alleviate this issue, automated, high-throughput sample processing methods were developed in which real-time PCR analysis is conducted on samples before and after incubation. The method, referred to as rapid-viability (RV)-PCR, uses the change in cycle threshold after incubation to detect the presence of live organisms. In this article, we report a novel RV-PCR method for detection of live, virulent Bacillus anthracis, in which the incubation time was reduced from 14 h to 9 h, bringing the total turnaround time for results below 15 h. The method incorporates a magnetic bead-based DNA extraction and purification step prior to PCR analysis, as well as specific real-time PCR assays for the B. anthracis chromosome and pXO1 and pXO2 plasmids. A single laboratory verification of the optimized method applied to the detection of virulent B. anthracis in environmental samples was conducted and showed a detection level of 10 to 99 CFU/sample with both manual and automated RV-PCR methods in the presence of various challenges. Experiments exploring the relationship between the incubation time and the limit of detection suggest that the method could be further shortened by an additional 2 to 3 h for relatively clean samples.
Real-Time, Polyphase-FFT, 640-MHz Spectrum Analyzer
NASA Technical Reports Server (NTRS)
Zimmerman, George A.; Garyantes, Michael F.; Grimm, Michael J.; Charny, Bentsian; Brown, Randy D.; Wilck, Helmut C.
1994-01-01
Real-time polyphase-fast-Fourier-transform, polyphase-FFT, spectrum analyzer designed to aid in detection of multigigahertz radio signals in two 320-MHz-wide polarization channels. Spectrum analyzer divides total spectrum of 640 MHz into 33,554,432 frequency channels of about 20 Hz each. Size and cost of polyphase-coefficient memory substantially reduced and much of processing loss of windowed FFTs eliminated.
Fujii, Roger
1988-01-01
Trace element and major ion concentrations were measured in water samples collected monthly between March 1985 and March 1986 at the MD-1 pumping station at the Tulare Lake Drainage District evaporation ponds, Kings County, California. Samples were analyzed for selected pesticides several times during the year. Salinity, as measured by specific conductance, ranged from 11,500 to 37,600 microsiemens/centimeter; total recoverable boron ranged from 4,000 to 16,000 micrg/L; and total recoverable molybdenum ranged from 630 to 2,600 microg/L. Median concentrations of total arsenic and total selenium were 97 and 2 microg/L. Atrazine, prometone, propazine, and simazine were the only pesticides detected in water samples collected at the MD-1 pumping station. Major ions, trace elements, and selected pesticides also were analyzed in water and bottom-sediment samples from five of the southern evaporation ponds at Tulare Lake Drainage District. Water enters the ponds from the MD-1 pumping station at pond 1 and flows through the system terminating at pond 10. The water samples increased in specific conductance (21,700 to 90,200 microsiemens/centimeter) and concentrations of total arsenic (110 to 420 microg/L), total recoverable boron (12,000 to 80,000 microg/L) and total recoverable molybdenum (1,200 to 5,500 microg/L) going from pond 1 to pond 10, respectively. Pesticides were not detected in water from any of the ponds sampled. Median concentrations of total arsenic and total selenium in the bottom sediments were 4.0 and 0.9 microg/g, respectively. The only pesticides detected in bottom sediment samples from the evaporation ponds were DDD and DDE, with maximum concentration of 0.8 microg/kilogram. (Author 's abstract)
Lasserre, Camille; De Saint Martin, Luc; Cuzon, Gaelle; Bogaerts, Pierre; Lamar, Estelle; Glupczynski, Youri; Naas, Thierry; Tandé, Didier
2015-07-01
The recognition of carbapenemase-producing Enterobacteriaceae (CPE) isolates is a major laboratory challenge, and their inappropriate or delayed detection may have negative impacts on patient management and on the implementation of infection control measures. We describe here a matrix-assisted laser desorption ionization-time of flight (MALDI-TOF)-based method to detect carbapenemase activity in Enterobacteriaceae. After a 20-min incubation of the isolate with 0.5 mg/ml imipenem at 37°C, supernatants were analyzed by MALDI-TOF in order to identify peaks corresponding to imipenem (300 Da) and an imipenem metabolite (254 Da). A total of 223 strains, 77 CPE (OXA-48 variants, KPC, NDM, VIM, IMI, IMP, and NMC-A) and 146 non-CPE (cephalosporinases, extended-spectrum β-lactamases [ESBLs], and porin defects), were tested and used to calculate a ratio of imipenem hydrolysis: mass spectrometry [MS] ratio = metabolite/(imipenem + metabolite). An MS ratio cutoff was statistically determined to classify strains as carbapenemase producers (MS ratio of ≥0.82). We validated this method first by testing 30 of our 223 isolates (15 CPE and 15 non-CPE) 10 times to calculate an intraclass correlation coefficient (ICC of 0.98), showing the excellent repeatability of the method. Second, 43 strains (25 CPE and 18 non-CPE) different from the 223 strains used to calculate the ratio cutoff were used as external controls and blind tested. They yielded sensitivity and specificity of 100%. The total cost per test is <0.10 U.S. dollars (USD). This easy-to-perform assay is time-saving, cost-efficient, and highly reliable and might be used in any routine laboratory, given the availability of mass spectrometry, to detect CPE. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
NASA Technical Reports Server (NTRS)
Yildiz, Yidiray; Kolmanovsky, Ilya V.; Acosta, Diana
2011-01-01
This paper proposes a control allocation system that can detect and compensate the phase shift between the desired and the actual total control effort due to rate limiting of the actuators. Phase shifting is an important problem in control system applications since it effectively introduces a time delay which may destabilize the closed loop dynamics. A relevant example comes from flight control where aggressive pilot commands, high gain of the flight control system or some anomaly in the system may cause actuator rate limiting and effective time delay introduction. This time delay can instigate Pilot Induced Oscillations (PIO), which is an abnormal coupling between the pilot and the aircraft resulting in unintentional and undesired oscillations. The proposed control allocation system reduces the effective time delay by first detecting the phase shift and then minimizing it using constrained optimization techniques. Flight control simulation results for an unstable aircraft with inertial cross coupling are reported, which demonstrate phase shift minimization and recovery from a PIO event.
NASA Astrophysics Data System (ADS)
Rambaldi, Marcello; Filimonov, Vladimir; Lillo, Fabrizio
2018-03-01
Given a stationary point process, an intensity burst is defined as a short time period during which the number of counts is larger than the typical count rate. It might signal a local nonstationarity or the presence of an external perturbation to the system. In this paper we propose a procedure for the detection of intensity bursts within the Hawkes process framework. By using a model selection scheme we show that our procedure can be used to detect intensity bursts when both their occurrence time and their total number is unknown. Moreover, the initial time of the burst can be determined with a precision given by the typical interevent time. We apply our methodology to the midprice change in foreign exchange (FX) markets showing that these bursts are frequent and that only a relatively small fraction is associated with news arrival. We show lead-lag relations in intensity burst occurrence across different FX rates and we discuss their relation with price jumps.
DETECTING INDUSTRIAL POLLUTION IN THE ATMOSPHERES OF EARTH-LIKE EXOPLANETS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Henry W.; Abad, Gonzalo Gonzalez; Loeb, Abraham, E-mail: henrylin@college.harvard.edu, E-mail: ggonzalezabad@cfa.harvard.edu, E-mail: aloeb@cfa.harvard.edu
Detecting biosignatures, such as molecular oxygen in combination with a reducing gas, in the atmospheres of transiting exoplanets has been a major focus in the search for alien life. We point out that in addition to these generic indicators, anthropogenic pollution could be used as a novel biosignature for intelligent life. To this end, we identify pollutants in the Earth's atmosphere that have significant absorption features in the spectral range covered by the James Webb Space Telescope. We focus on tetrafluoromethane (CF{sub 4}) and trichlorofluoromethane (CCl{sub 3}F), which are the easiest to detect chlorofluorocarbons (CFCs) produced by anthropogenic activity. Wemore » estimate that ∼1.2 days (∼1.7 days) of total integration time will be sufficient to detect or constrain the concentration of CCl{sub 3}F (CF{sub 4}) to ∼10 times the current terrestrial level.« less
Total leisure noise exposure and its association with hearing loss among adolescents.
Dehnert, Knut; Raab, Ulla; Perez-Alvarez, Carmelo; Steffens, Thomas; Bolte, Gabriele; Fromme, Hermann; Twardella, Dorothee
2015-01-01
To investigate total leisure noise exposure among adolescents and to assess its association with hearing. Based on self-reported time spent on 19 leisure activities and associated mean sound pressure levels reported in the literature, total leisure noise exposure was evaluated and compared to noise at work limits (> 85 dB(A) = hazardous) in a cross-sectional survey. Tympanometry and pure-tone audiometry was performed in sound isolated rooms. The study sample consists of 2143 pupils attending grade nine in any school in a German city 2009-2011 (mean age: 15.4 years; range: 13-19 years). Audiometric data were available for 1837 (85.8%) pupils (53.9% girls). 41.9% of the 2143 adolescents who had provided self-reported data on leisure activities associated with noise exposure were estimated to be hazardously exposed to leisure time noise. The interaction of gender with total leisure time noise exposure was not significant. No association between leisure time noise exposure and audiometric notches could be detected. While hearing loss seems seldom in this age group, a high proportion of adolescents aged 15-16 years are exposed to noise levels during leisure time bearing long-term risks of hearing loss.
Puzon, Geoffrey J; Lancaster, James A; Wylie, Jason T; Plumb, Iason J
2009-09-01
Rapid detection of pathogenic Naegleria fowler in water distribution networks is critical for water utilities. Current detection methods rely on sampling drinking water followed by culturing and molecular identification of purified strains. This culture-based method takes an extended amount of time (days), detects both nonpathogenic and pathogenic species, and does not account for N. fowleri cells associated with pipe wall biofilms. In this study, a total DNA extraction technique coupled with a real-time PCR method using primers specific for N. fowleri was developed and validated. The method readily detected N. fowleri without preculturing with the lowest detection limit for N. fowleri cells spiked in biofilm being one cell (66% detection rate) and five cells (100% detection rate). For drinking water, the detection limit was five cells (66% detection rate) and 10 cells (100% detection rate). By comparison, culture-based methods were less sensitive for detection of cells spiked into both biofilm (66% detection for <10 cells) and drinking water (0% detection for <10 cells). In mixed cultures of N. fowleri and nonpathogenic Naegleria, the method identified N. fowleri in 100% of all replicates, whereastests with the current consensus primers detected N. fowleri in only 5% of all replicates. Application of the new method to drinking water and pipe wall biofilm samples obtained from a distribution network enabled the detection of N. fowleri in under 6 h, versus 3+ daysforthe culture based method. Further, comparison of the real-time PCR data from the field samples and the standard curves enabled an approximation of N. fowleri cells in the biofilm and drinking water. The use of such a method will further aid water utilities in detecting and managing the persistence of N. fowleri in water distribution networks.
Xiong, Yu-xia; Meng, Xian-li; Yang, Na; Zhang, Yi; He, Yu-min
2007-01-01
To observe the effect of effective fractions (Conjunct anthraquinone, free anthraquinone and total flavonoids) and its compatibilities and proportions of Xie-Xin decoction on NO production in peritonea macrophaes from rat. Growth activity of macrophages cultured with different levels of active components were detected by MTT. NO concentrations in peritoneal macrophages induced by LPS were detected by Griess method. The NO production from macrophages induced by LPS was inhibited obviously by active components at the levels of 0.01-0.1 mg/ml. The best time of administration was 1 h induced by LPS. The inhibition of best proportions of compatibilities of Conjunct anthraquinone and total flavonoids, free anthraquinone and total flavonoids were stronger than effective fractions solo. The NO production is inhibited obviously by these effective fractions, especially by conjunct anthraquinone. Effective fractions can inhibit the function of activated macrophages.
NASA Astrophysics Data System (ADS)
Zhou, Sheng; Han, Yanling; Li, Bincheng
2018-02-01
Nitric oxide (NO) in exhaled breath has gained increasing interest in recent years mainly driven by the clinical need to monitor inflammatory status in respiratory disorders, such as asthma and other pulmonary conditions. Mid-infrared cavity ring-down spectroscopy (CRDS) using an external cavity, widely tunable continuous-wave quantum cascade laser operating at 5.3 µm was employed for NO detection. The detection pressure was reduced in steps to improve the sensitivity, and the optimal pressure was determined to be 15 kPa based on the fitting residual analysis of measured absorption spectra. A detection limit (1σ, or one time of standard deviation) of 0.41 ppb was experimentally achieved for NO detection in human breath under the optimized condition in a total of 60 s acquisition time (2 s per data point). Diurnal measurement session was conducted for exhaled NO. The experimental results indicated that mid-infrared CRDS technique has great potential for various applications in health diagnosis.
Rand, Kenneth H.; Rampersaud, Howard; Houck, Herbert J.
2011-01-01
We compared the FilmArray RP (Idaho Technology, Inc., Salt Lake City, UT) and the xTAG RVP (Luminex Corporation, Toronto, Canada) multiplex respiratory virus PCR methods for the detection of respiratory viruses in a set of 200 patient specimens frozen at −70°C after standard viral culture and antigen detection methods were done. Both systems detected between 40 to 50% more viruses than traditional methods, primarily rhinoviruses and human metapneumovirus. The FilmArray RP detected significantly more total viruses either alone or as part of mixed infections than the xTAG RVP, as well as an additional 21.6% more respiratory syncytial viruses. The xTAG RVP requires 5 to 6 h with 2.5 to 3 h of hands-on time, while the FilmArray RP takes about an hour with 3 to 5 min of hands-on time, making it much easier to perform. PMID:21508156
Baker, Mark E; Bogoni, Luca; Obuchowski, Nancy A; Dass, Chandra; Kendzierski, Renee M; Remer, Erick M; Einstein, David M; Cathier, Pascal; Jerebko, Anna; Lakare, Sarang; Blum, Andrew; Caroline, Dina F; Macari, Michael
2007-10-01
To determine whether computer-aided detection (CAD) applied to computed tomographic (CT) colonography can help improve sensitivity of polyp detection by less-experienced radiologist readers, with colonoscopy or consensus used as the reference standard. The release of the CT colonographic studies was approved by the individual institutional review boards of each institution. Institutions from the United States were HIPAA compliant. Written informed consent was waived at all institutions. The CT colonographic studies in 30 patients from six institutions were collected; 24 images depicted at least one confirmed polyp 6 mm or larger (39 total polyps) and six depicted no polyps. By using an investigational software package, seven less-experienced readers from two institutions evaluated the CT colonographic images and marked or scored polyps by using a five-point scale before and after CAD. The time needed to interpret the CT colonographic findings without CAD and then to re-evaluate them with CAD was recorded. For each reader, the McNemar test, adjusted for clustered data, was used to compare sensitivities for readers without and with CAD; a Wilcoxon signed-rank test was used to analyze the number of false-positive results per patient. The average sensitivity of the seven readers for polyp detection was significantly improved with CAD-from 0.810 to 0.908 (P=.0152). The number of false-positive results per patient without and with CAD increased from 0.70 to 0.96 (95% confidence interval for the increase: -0.39, 0.91). The mean total time for the readings was 17 minutes 54 seconds; for interpretation of CT colonographic findings alone, the mean time was 14 minutes 16 seconds; and for review of CAD findings, the mean time was 3 minutes 38 seconds. Results of this feasibility study suggest that CAD for CT colonography significantly improves per-polyp detection for less-experienced readers. Copyright (c) RSNA, 2007.
Chen, Chien-Chou; Teng, Yung-Chu; Lin, Bo-Cheng; Fan, I-Chun; Chan, Ta-Chien
2016-11-25
Cases of dengue fever have increased in areas of Southeast Asia in recent years. Taiwan hit a record-high 42,856 cases in 2015, with the majority in southern Tainan and Kaohsiung Cities. Leveraging spatial statistics and geo-visualization techniques, we aim to design an online analytical tool for local public health workers to prospectively identify ongoing hot spots of dengue fever weekly at the village level. A total of 57,516 confirmed cases of dengue fever in 2014 and 2015 were obtained from the Taiwan Centers for Disease Control (TCDC). Incorporating demographic information as covariates with cumulative cases (365 days) in a discrete Poisson model, we iteratively applied space-time scan statistics by SaTScan software to detect the currently active cluster of dengue fever (reported as relative risk) in each village of Tainan and Kaohsiung every week. A village with a relative risk >1 and p value <0.05 was identified as a dengue-epidemic area. Assuming an ongoing transmission might continuously spread for two consecutive weeks, we estimated the sensitivity and specificity for detecting outbreaks by comparing the scan-based classification (dengue-epidemic vs. dengue-free village) with the true cumulative case numbers from the TCDC's surveillance statistics. Among the 1648 villages in Tainan and Kaohsiung, the overall sensitivity for detecting outbreaks increases as case numbers grow in a total of 92 weekly simulations. The specificity for detecting outbreaks behaves inversely, compared to the sensitivity. On average, the mean sensitivity and specificity of 2-week hot spot detection were 0.615 and 0.891 respectively (p value <0.001) for the covariate adjustment model, as the maximum spatial and temporal windows were specified as 50% of the total population at risk and 28 days. Dengue-epidemic villages were visualized and explored in an interactive map. We designed an online analytical tool for front-line public health workers to prospectively detect ongoing dengue fever transmission on a weekly basis at the village level by using the routine surveillance data.
Alkylphenols in adipose tissues of Italian population.
Ferrara, Fulvio; Ademollo, Nicoletta; Orrù, Maria Antonietta; Silvestroni, Leopoldo; Funari, Enzo
2011-02-01
Alkylphenols (APs) and AP ethoxylated compounds (APEs) were screened in human subcutaneous adipose tissue samples from Italy. The samples were collected during bariatric surgery from 16 subjects (three men and 13 women) and a total of seven alkylphenol compounds (APs) was detected. Nonylphenol (NP) was the compound found at the highest level (mean 122 ng g⁻¹ fresh weight; range 10-266 ng g⁻¹ fw). Several nonylphenol ethoxylates (NPEOs) were found in all the sample analysed though the frequency of detection decreased with the increasing number of ethoxylic groups. NP4EO was found only in four patients ranging from trace amounts to 41.3 ng g⁻¹ fw. Total nonylphenols (NPEs) ranged between 45 and 1131 ng g⁻¹ fw, whereas the concentration of total octylphenols (OPEs) was at least 10 times lower (range 6-80 ng g⁻¹ fw). Our findings show that the average concentration of NP is about two times higher than that found in women from Southern Spain and up to three times that of people from Switzerland. Similarly, OP mean level is two times that reported in Finland and Spain populations. This is the first study that reports the presence of alkylphenols in the Italian population adipose tissue and it draws a baseline for further researches in order to depict a trend in human exposure to these compounds and to investigate possible consequences for human health. Copyright © 2010 Elsevier Ltd. All rights reserved.
Messner, Michael J; Berger, Philip; Javier, Julie
2017-06-01
Public water systems (PWSs) in the United States generate total coliform (TC) and Escherichia coli (EC) monitoring data, as required by the Total Coliform Rule (TCR). We analyzed data generated in 2011 by approximately 38,000 small (serving fewer than 4101 individuals) undisinfected public water systems (PWSs). We used statistical modeling to characterize a distribution of TC detection probabilities for each of nine groupings of PWSs based on system type (community, non-transient non-community, and transient non-community) and population served (less than 101, 101-1000 and 1001-4100 people). We found that among PWS types sampled in 2011, on average, undisinfected transient PWSs test positive for TC 4.3% of the time as compared with 3% for undisinfected non-transient PWSs and 2.5% for undisinfected community PWSs. Within each type of PWS, the smaller systems have higher median TC detection than the larger systems. All TC-positive samples were assayed for EC. Among TC-positive samples from small undisinfected PWSs, EC is detected in about 5% of samples, regardless of PWS type or size. We evaluated the upper tail of the TC detection probability distributions and found that significant percentages of some system types have high TC detection probabilities. For example, assuming the systems providing data are nationally-representative, then 5.0% of the ∼50,000 small undisinfected transient PWSs in the U.S. have TC detection probabilities of 20% or more. Communities with such high TC detection probabilities may have elevated risk of acute gastrointestinal (AGI) illness - perhaps as great or greater than the attributable risk to drinking water (6-22%) calculated for 14 Wisconsin community PWSs with much lower TC detection probabilities (about 2.3%, Borchardt et al., 2012). Published by Elsevier GmbH.
A versatile optical microscope for time-dependent single-molecule and single-particle spectroscopy
NASA Astrophysics Data System (ADS)
Li, Hao; Yang, Haw
2018-03-01
This work reports the design and implementation of a multi-function optical microscope for time-dependent spectroscopy on single molecules and single nanoparticles. It integrates the now-routine single-object measurements into one standalone platform so that no reconfiguration is needed when switching between different types of sample or spectroscopy modes. The illumination modes include evanescent field through total internal reflection, dark-field illumination, and epi-excitation onto a diffraction-limited spot suitable for confocal detection. The detection modes include spectrally resolved line imaging, wide-field imaging with dual-color capability, and two-color single-element photon-counting detection. The switch between different spectroscopy and data acquisition modes is fully automated and executed through computer programming. The capability of this microscope is demonstrated through selected proof-of-principle experiments.
A versatile optical microscope for time-dependent single-molecule and single-particle spectroscopy.
Li, Hao; Yang, Haw
2018-03-28
This work reports the design and implementation of a multi-function optical microscope for time-dependent spectroscopy on single molecules and single nanoparticles. It integrates the now-routine single-object measurements into one standalone platform so that no reconfiguration is needed when switching between different types of sample or spectroscopy modes. The illumination modes include evanescent field through total internal reflection, dark-field illumination, and epi-excitation onto a diffraction-limited spot suitable for confocal detection. The detection modes include spectrally resolved line imaging, wide-field imaging with dual-color capability, and two-color single-element photon-counting detection. The switch between different spectroscopy and data acquisition modes is fully automated and executed through computer programming. The capability of this microscope is demonstrated through selected proof-of-principle experiments.
NASA Astrophysics Data System (ADS)
Walker, Gary E.
2015-01-01
We observe the long period (5.6 years) Eclipsing Binary Variable Star EE Cep during it's 2014 eclipse. It was observed on every clear night from the Maria Mitchell Observatory as well as remote sites for a total of 25 nights. Each night consisted of a detailed time series in BVRI looking for short term variations for a total of >9000 observations. The data was transformed to the Standard System. In addition, a time series was captured during the night of the eclipse. This data provides an alternate method to determine Time of Minimum than traditionally performed. The TOM varied with color. Several strong correlations are seen between colors substantiating the detection of variations on a time scale of hours. The long term light curve shows 5 interesting and different Phases with different characteristics.
Malandraki, Ioanna; Varveri, Christina; Olmos, Antonio; Vassilakos, Nikon
2015-03-01
A one-step multiplex real-time quantitative reverse transcription polymerase chain reaction (RT-qPCR) based on TaqMan chemistry was developed for the simultaneous detection of Pear blister canker viroid and Apple scar skin viroid along with universal detection of phytoplasmas, in pome trees. Total nucleic acids (TNAs) extraction was performed according to a modified CTAB protocol. Primers and TaqMan MGB probes for specific detection of the two viroids were designed in this study, whereas for phytoplasma detection published universal primers and probe were used, with the difference that the later was modified to carry a MGB quencher. The pathogens were detected simultaneously in 10-fold serial dilutions of TNAs from infected plant material into TNAs of healthy plant up to dilutions 10(-5) for viroids and 10(-4) for phytoplasmas. The multiplex real-time assay was at least 10 times more sensitive than conventional protocols for viroid and phytoplasma detection. Simultaneous detection of the three targets was achieved in composite samples at least up to a ratio of 1:100 triple-infected to healthy tissue, demonstrating that the developed assay has the potential to be used for rapid and massive screening of viroids and phytoplasmas of pome fruit trees in the frame of certification schemes and surveys. Copyright © 2014 Elsevier B.V. All rights reserved.
Prescott, Meagan A.; Reed, Aimee N.; Jin, Ling; Pastey, Manoj K.
2018-01-01
Since the emergence of cyprinid herpes virus 3 (CyHV-3), outbreaks have been devastating to koi and common carp leading to high economic losses. Current diagnostics for detecting CyHV-3 are limited in sensitivity and are further complicated by latency. Here we describe the detection of CyHV-3 by recombinase polymerase amplification (RPA). The RPA assay can detect as low as 10 copies of CyHV-3 genome by an isothermal reaction and yields results in approximately 20 minutes. Using the RPA assay, CyHV-3 genome can be detected in total DNA of white blood cells isolated from koi latently infected with CyHV-3, while less than 10% of the latently infected koi can be detected by a real-time PCR assay in total DNA of white blood cells. In addition, RPA products can be detected in a lateral flow device that is cheap, fast, and can be used outside of the diagnostic lab. The RPA assay and lateral flow device provide for the rapid, sensitive, and specific amplification of CyHV-3 that with future modifications for field use and validation could lead to enhanced surveillance and early diagnosis of CyHV-3 in the laboratory and field. PMID:27485254
Qualitative and quantitative analysis of flavonoids from 12 species of Korean mulberry leaves.
Ju, Wan-Taek; Kwon, O-Chul; Kim, Hyun-Bok; Sung, Gyoo-Byung; Kim, Heon-Woong; Kim, Yong-Soon
2018-05-01
The total flavonoids in leaves of 12 varieties of Korean mulberry ( Morus alba L.) were determined. Seventeen flavonoids were isolated and analyzed using ultra-performance liquid chromatography coupled with diode array detection and quadrupole time-of-flight mass spectrometry (UPLC-DAD-QTOF/MS). To determine the flavonoid contents, HPLC analysis was performed on these 17 flavonoids. The total flavonoid contents of the 12 varieties of mulberry leaves ranged from 748.5 to 1297.9 mg, with the highest obtained from the Cheong Su variety (1297.9 ± 112.0 mg). Among the 17 flavonoids analyzed, quercetin 3- O -rutinoside (rutin) and quercetin 3- O -glucoside (isoquercitrin) had highest contents in the Cheong Su variety. Furthermore, the Dae Dang Sang variety gave the highest quercetin 3- O -rutinoside (rutin) content among the mulberry leaves investigated, at 425.5 ± 45.9 mg. Major flavonols from Dae Dang Sang were detected by UPLC-DAD-QTOF/MS. A total of 17 flavonoid compound peaks were identified in the analysis time range of 5-40 min, all of which were kaempferol and quercetin glycosides. Seven of the 17 compounds identified in mulberry leaves were unknown.
Real-Time Gait Event Detection Based on Kinematic Data Coupled to a Biomechanical Model.
Lambrecht, Stefan; Harutyunyan, Anna; Tanghe, Kevin; Afschrift, Maarten; De Schutter, Joris; Jonkers, Ilse
2017-03-24
Real-time detection of multiple stance events, more specifically initial contact (IC), foot flat (FF), heel off (HO), and toe off (TO), could greatly benefit neurorobotic (NR) and neuroprosthetic (NP) control. Three real-time threshold-based algorithms have been developed, detecting the aforementioned events based on kinematic data in combination with a biomechanical model. Data from seven subjects walking at three speeds on an instrumented treadmill were used to validate the presented algorithms, accumulating to a total of 558 steps. The reference for the gait events was obtained using marker and force plate data. All algorithms had excellent precision and no false positives were observed. Timing delays of the presented algorithms were similar to current state-of-the-art algorithms for the detection of IC and TO, whereas smaller delays were achieved for the detection of FF. Our results indicate that, based on their high precision and low delays, these algorithms can be used for the control of an NR/NP, with the exception of the HO event. Kinematic data is used in most NR/NP control schemes and is thus available at no additional cost, resulting in a minimal computational burden. The presented methods can also be applied for screening pathological gait or gait analysis in general in/outside of the laboratory.
NASA Astrophysics Data System (ADS)
Akhoondzadeh, M.
2013-08-01
On 6 February 2013, at 12:12:27 local time (01:12:27 UTC) a seismic event registering Mw 8.0 struck the Solomon Islands, located at the boundaries of the Australian and Pacific tectonic plates. Time series prediction is an important and widely interesting topic in the research of earthquake precursors. This paper describes a new computational intelligence approach to detect the unusual variations of the total electron content (TEC) seismo-ionospheric anomalies induced by the powerful Solomon earthquake using genetic algorithm (GA). The GA detected a considerable number of anomalous occurrences on earthquake day and also 7 and 8 days prior to the earthquake in a period of high geomagnetic activities. In this study, also the detected TEC anomalies using the proposed method are compared to the results dealing with the observed TEC anomalies by applying the mean, median, wavelet, Kalman filter, ARIMA, neural network and support vector machine methods. The accordance in the final results of all eight methods is a convincing indication for the efficiency of the GA method. It indicates that GA can be an appropriate non-parametric tool for anomaly detection in a non linear time series showing the seismo-ionospheric precursors variations.
Prospective randomized controlled trial evaluating cap-assisted colonoscopy vs standard colonoscopy
Tee, Hoi-Poh; Corte, Crispin; Al-Ghamdi, Hamdan; Prakoso, Emilia; Darke, John; Chettiar, Raman; Rahman, Wassim; Davison, Scott; Griffin, Sean P; Selby, Warwick S; Kaffes, Arthur J
2010-01-01
AIM: To study the significance of cap-fitted colonoscopy in improving cecal intubation time and polyp detection rate. METHODS: This study was a prospective randomized controlled trial conducted from March 2008 to February 2009 in a tertiary referral hospital at Sydney. The primary end point was cecal intubation time and the secondary endpoint was polyp detection rate. Consecutive cases of total colonoscopy over a 1-year period were recruited. Randomization into either standard colonoscopy (SC) or cap-assisted colonoscopy (CAC) was performed after consent was obtained. For cases randomized to CAC, one of the three sizes of cap was used: D-201-15004 (with a diameter of 15.3 mm), D-201-14304 (14.6 mm) and D-201-12704 (13.0 mm). All of these caps were produced by Olympus Medical Systems, Japan. Independent predictors for faster cecal time and better polyp detection rate were also determined from this study. RESULTS: There were 200 cases in each group. There was no significant difference in terms of demographic characteristics between the two groups. CAC, when compared to the SC group, had no significant difference in terms of cecal intubation rate (96.0% vs 97.0%, P = 0.40) and time (9.94 ± 7.05 min vs 10.34 ± 6.82 min, P = 0.21), or polyp detection rate (32.8% vs 31.3%, P = 0.75). On the subgroup analysis, there was no significant difference in terms of cecal intubation time by trainees (88.1% vs 84.8%, P = 0.40), ileal intubation rate (82.5% vs 79.0%, P = 0.38) or total colonoscopy time (23.24 ± 13.95 min vs 22.56 ± 9.94 min, P = 0.88). On multivariate analysis, the independent determinants of faster cecal time were consultant-performed procedures (P < 0.001), male patients (P < 0.001), non-usage of hyoscine (P < 0.001) and better bowel preparation (P = 0.01). The determinants of better polyp detection rate were older age (P < 0.001), no history of previous abdominal surgery (P = 0.04), patients not having esophagogastroduodenoscopy in the same setting (P = 0.003), trainee-performed procedures (P = 0.01), usage of hyoscine (P = 0.01) and procedures performed for polyp follow-up (P = 0.01). The limitations of the study were that it was a single-center experience, no blinding was possible, and there were a large number of endoscopists. CONCLUSION: CAC did not significantly different from SC in term of cecal intubation time and polyp detection rate. PMID:20712051
Environmental Sampling for Avian Influenza A(H7N9) in Live-Poultry Markets in Guangdong, China.
Kang, Min; He, Jianfeng; Song, Tie; Rutherford, Shannon; Wu, Jie; Lin, Jinyan; Huang, Guofeng; Tan, Xiaohua; Zhong, Haojie
2015-01-01
To provide an increased understanding of avian influenza A(H7N9) activity in live-poultry market in space and time and hence improve H7N9 epidemic control, an ongoing environmental sampling program in multiple live-poultry markets across Guangdong, China was conducted during March 2013-June 2014. A total of 625 live-poultry markets throughout 21 prefecture areas took part in the study. A total of 10 environmental sites in markets for sampling were identified to represent 4 different poultry-related activity areas. At least 10 environmental samples were collected from each market every month. The real time RT-PCR was performed to detect the avian influenza A(H7N9) virus. Field survey was conducted to investigate the sanitation status of live-poultry markets. There were 109 human infections with H7N9 avian influenza in Guangdong, of which 37 (34%) died. A total of 18741 environmental swabs were collected and subjected to real-time RT-PCR test, of which 905(4.83%) were found positive for H7N9 virus. There were 201 (32.16%) markets affected by H7N9 in 16 prefecture areas. The detection of H7N9 virus in markets spiked in winter months. 63.33% markets (38/60) had no physical segregation for poultry holding, slaughter or sale zones. Closing live-poultry market significantly decreased the H7N9 detection rate from 14.83% (112/755) to 1.67% (5/300). This study indicates the importance of live-poultry market surveillance based on environmental sampling for H7N9 Avian Influenza control. Improving live-poultry market management and sanitation and changing consumer practices are critical to reduce the risk of H7N9 infection.
Coleman, Russell E; Hochberg, Lisa P; Swanson, Katherine I; Lee, John S; McAvin, James C; Moulton, John K; Eddington, David O; Groebner, Jennifer L; O'Guinn, Monica L; Putnam, John L
2009-05-01
Sand flies collected between April 2003 and November 2004 at Tallil Air Base, Iraq, were evaluated for the presence of Leishmania parasites using a combination of a real-time Leishmania-generic polymerase chain reaction (PCR) assay and sequencing of a 360-bp fragment of the glucose-6-phosphate-isomerase (GPI) gene. A total of 2,505 pools containing 26,574 sand flies were tested using the real-time PCR assay. Leishmania DNA was initially detected in 536 pools; however, after extensive retesting with the real-time PCR assay, a total of 456 pools were considered positive and 80 were considered indeterminate. A total of 532 samples were evaluated for Leishmania GPI by sequencing, to include 439 PCR-positive samples, 80 PCR-indeterminate samples, and 13 PCR-negative samples. Leishmania GPI was detected in 284 samples that were sequenced, to include 281 (64%) of the PCR-positive samples and 3 (4%) of the PCR-indeterminate samples. Of the 284 sequences identified as Leishmania, 261 (91.9%) were L. tarentolae, 18 (6.3%) were L. donovani-complex parasites, 3 (1.1%) were L. tropica, and 2 were similar to both L. major and L. tropica. Minimum field infection rates were 0.09% for L. donovani-complex parasites, 0.02% for L. tropica, and 0.01% for the L. major/tropica-like parasite. Subsequent sequencing of a 600-bp region of the "Hyper" gene of 12 of the L. donovani-complex parasites showed that all 12 parasites were L. infantum. These data suggest that L. infantum was the primary leishmanial threat to U.S. military personnel deployed to Tallil Air Base. The implications of these findings are discussed.
Zhang, Lahong; Dai, Yibei; Chen, Jiahuan; Hong, Liquan; Liu, Yuhua; Ke, Qiang; Chen, Yiwen; Cai, Chengsong; Liu, Xia; Chen, Zhaojun
2018-01-01
A new multiplex real-time PCR assay, the high-risk HPV genotyping real time PCR assay (HR HPV RT-PCR), has been developed to detect 15 high-risk HPV types with respective viral loads. In this report, a total of 684 cervical specimens from women diagnosed with vaginitis were assessed by the HR HPV RT-PCR and the PCR reaction and reverse dot blot (PCR-RDB) assays, using a PCR-sequencing method as a reference standard. A total coincidence of 97.7% between the HR HPV RT PCR and the PCR-RDB assays was determined with a Kappa value of 0.953. The HR HPV RT PCR assay had sensitivity, specificity, and concordance rates (accuracy) of 99.7%, 99.7%, and 99.7%, respectively, as confirmed by PCR-sequencing, while the PCR-RDB assay had respective rates of 98.8%, 97.1%, and 98.0%. The overall rate of HPV infection, determined by PCR-sequencing, in women diagnosed with vaginitis was 49.85%, including 36.26% of single infection and 13.6% of multiple infections. The most common infections among the 15 high-risk HPV types in women diagnosed with vaginitis were HPV-52, HPV-16, and HPV-58, with a total detection rate of 10.23%, 7.75%, and 5.85%, respectively. We conclude that the HR HPV RT PCR assay exhibits better clinical performance than the PCR-RDB assay, and is an ideal alternative method for HPV genotyping. In addition, the HR HPV RT PCR assay provides HPV DNA viral loads, and could serve as a quantitative marker in the diagnosis and treatment of single and multiple HPV infections. © 2017 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Hata, Yutaka; Kanazawa, Seigo; Endo, Maki; Tsuchiya, Naoki; Nakajima, Hiroshi
2012-06-01
This paper proposes a heart rate monitoring system for detecting autonomic nervous system by the heart rate variability using an air pressure sensor to diagnose mental disease. Moreover, we propose a human behavior monitoring system for detecting the human trajectory in home by an infrared camera. In day and night times, the human behavior monitoring system detects the human movement in home. The heart rate monitoring system detects the heart rate in bed in night time. The air pressure sensor consists of a rubber tube, cushion cover and pressure sensor, and it detects the heart rate by setting it to bed. It unconstraintly detects the RR-intervals; thereby the autonomic nervous system can be assessed. The autonomic nervous system analysis can examine the mental disease. While, the human behavior monitoring system obtains distance distribution image by an infrared camera. It classifies adult, child and the other object from distance distribution obtained by the camera, and records their trajectories. This behavior, i.e., trajectory in home, strongly corresponds to cognitive disorders. Thus, the total system can detect mental disease and cognitive disorders by uncontacted sensors to human body.
Trends in Water Quality in the Southeastern United States, 1973-2005
Harned, Douglas A.; Staub, Erik L.; Peak, Kelly L.; Tighe, Kirsten M.; Terziotti, Silvia
2009-01-01
As part of the U.S. Geological Survey National Water-Quality Assessment Program, water-quality data for 334 streams in eight States of the Southeastern United States were assessed for trends from 1973 to 2005. Forty-four U.S. Geological Survey sites were examined for trends in pH, specific conductance, and dissolved oxygen, and in concentrations of dissolved solids, suspended sediment, chloride, sodium, sulfate, silica, potassium, dissolved organic carbon, total nitrogen, total ammonia, total ammonia plus organic nitrogen, dissolved nitrite plus nitrate, and total phosphorus. An additional 290 sites from the U.S. Environmental Protection Agency Storage and Retrieval database were tested for trends in total nitrogen and phosphorus concentrations for the 1975-2004 and 1993-2004 periods. The seasonal Kendall test or Tobit regression was used to detect trends. Concentrations of dissolved constituents have increased in the Southeast during the last 30 years. Specific conductance increased at 62 percent and decreased at 3 percent of the sites, and pH increased at 31 percent and decreased at 11 percent of the sites. Decreasing trends in total nitrogen were detected at 49 percent of the sites, and increasing trends were detected at 10 percent of the sites. Ammonia concentrations decreased at 27 percent of the sites and increased at 6 percent of the sites. Nitrite plus nitrate concentrations increased at 29 percent of the sites and decreased at 10 percent of the sites. These results indicate that the changes in stream nitrogen concentrations generally coincided with improved municipal wastewater-treatment methods. Long-term decreasing trends in total phosphorus were detected at 56 percent of the sites, and increasing trends were detected at 8 percent of the sites. Concentrations of phosphorus have decreased over the last 35 years, which coincided with phosphate-detergent bans and improvements in wastewater treatment that were implemented beginning in 1972. Multiple regression analysis indicated a relation between changes in atmospheric inputs and agricultural practices, and changes in water quality. A long-term water-quality and landscape trends-assessment network for the Southeast is needed to assess changes in water quality over time in response to variations in population, agricultural, wastewater, and landscape variables.
Benefits of Time Correlation Measurements for Passive Screening
NASA Astrophysics Data System (ADS)
Murer, David; Blackie, Douglas; Peerani, Paolo
2014-02-01
The “FLASH Portals Project” is a collaboration between Arktis Radiation Detectors Ltd (CH), the Atomic Weapons Establishment (UK), and the Joint Research Centre (European Commission), supported by the Technical Support Working Group (TSWG). The program's goal was to develop and demonstrate a technology to detect shielded special nuclear materials (SNM) more efficiently and less ambiguously by exploiting time correlation. This study presents experimental results of a two-sided portal monitor equipped with in total 16 4He fast neutron detectors as well as four polyvinyltoluene (PVT) plastic scintillators. All detectors have been synchronized to nanosecond precision, thereby allowing the resolution of time correlations from timescales of tens of microseconds (such as (n, γ) reactions) down to prompt fission correlations directly. Our results demonstrate that such correlations can be detected in a typical radiation portal monitor (RPM) geometry and within operationally acceptable time scales, and that exploiting these signatures significantly improves the performance of the RPM compared to neutron counting. Furthermore, the results show that some time structure remains even in the presence of heavy shielding, thus significantly improving the sensitivity of the detection system to shielded SNM.
Ruiz, Pilar; Causse, Manuel; Vaquero, Manuel; Gutierrez, Juan Bautista; Casal, Manuel
2017-01-01
A new automated real-time PCR assay for the detection of rifampicin (RIF) and isoniazid (INH) resistance in Mycobacterium tuberculosis (MTB) was evaluated. A total of 163 clinical samples (128 pulmonary and 35 extra-pulmonary) were processed using four PCR assay kits: Abbott RealTime MTB RIF/INH, Genotype MTBDRplus, Xpert/MTB RIF, and Anyplex MTB/MDR. The results of phenotypic drug-susceptibility testing using BACTECMGIT 960 were used as reference. The sensitivity and specificity of the new Abbott RealTime MTB RIF/INH assay in comparison with phenotypic testing was 96.3% (95%CI 87.32%-100%) for RIF and 100% (95%CI 99.3%-100%) for INH; the sensitivity was 78.8% (95%CI 66.8%-90.9%) and the specificity was 100% (95%CI 98.9%-100%). The Abbott RealTime MTB RIF/INH test could be a valid method for detecting the most common mutations in strains resistant to RIF and INH.
Greer, Brett; Maul, Ronald; Campbell, Katrina; Elliott, Christopher T
2017-06-01
Recently, there has been a rise in freshwater harmful algal blooms (HABs) globally, as well as increasing aquaculture practices. HABs can produce cyanotoxins, many of which are hepatotoxins. An ultra-performance liquid chromatography tandem mass spectrometry method was developed and validated for nine cyanotoxins across three classes including six microcystins, nodularin, cylindrospermopsin and anatoxin-a. The method was used to analyse free cyanotoxin(s) in muscle (n = 34), liver (n = 17) and egg (n = 9) tissue samples of 34 fish sourced from aquaculture farms in Southeast Asia. Conjugated microcystin was analysed by Lemieux oxidation to ascertain the total amount of microcystin present in muscle. Some tilapia accumulated free microcystin-LR in the muscle tissue at a mean of 15.45 μg/kg dry weight (dw), with total microcystin levels detected at a mean level of 110.1 μg/kg dw, indicating that the amount of conjugated or masked microcystin present in the fish muscle accounted for 85% of the total. Higher levels of cyanotoxin were detected in the livers, with approximately 60% of those tested being positive for microcystin-LR and microcystin-LF, along with cylindrospermopsin. Two fish from one of the aquaculture farms contained cylindrospermopsin in the eggs; the first time this has been reported. The estimated daily intake for free and total microcystins in fish muscle tissue was 2 and 14 times higher, respectively, than the tolerable daily intake value. This survey presents the requirement for further monitoring of cyanotoxins, including masked microcystins, in aquaculture farming in these regions and beyond, along with the implementation of guidelines to safeguard human health. Graphical abstract ᅟ.
Time course of total and food specific IgE antibodies (Rast Fx5) in the developing allergic child.
Kalach, Nicolas; Soulaines, Pascale; Guerin, Sylvie; de Boissieu, Delphine; Dupont, Christophe
2005-09-01
To analyze the evolution of total and food specific IgE (Rast Fx5) titers in the course of food allergy in children. 925 children, mean age 8.9 + 9.1 years (15 days-18 years), 455 girls and 470 boys, investigated for food allergy in year 1997, underwent serum samples assay for total IgE and of Rast Fx5, Cap System, Pharmacia & Upjohn Diagnostics AB, Uppsala, Sweden, a mix test detecting specific IgE to 6 major food allergens in children, cow's milk proteins (CMP), egg white, peanut, soy, wheat and fish and analyzed as a function of reference values by age. Total IgE titers increased significantly with age, r0.22, p0.0001. The percentage of children with a total IgE level above normal range first increased with age, from 10.3 % at 0-6 months, reaching 38.2 % at 1-2 years and peaking at 56.9% at 4-6 years, then leveled off, 48.1% at 8-12 years (ns vs 4-6 years) and 41.3% above 12 years (ns). Detectable Rast Fx5 increased in a parallel manner until age 4-6 years and then exhibited a progressive decrease from age 6-8 years, differing significantly from total IgE: 31.9% vs 52.9%, p0.01 (6-8 years), 32.2% vs 48.1%, p0.03 (8-12 years), 21.8% vs 41.3%, p0.05 (> 12 years). In these outpatient children investigated for food allergy, the increase with age of the percentage of high total IgE contrasted with the progressive decrease of Rast Fx5 from age 4-6 yr. This biological finding correlates timely with the clinical spontaneous decrease of food allergy in the developing child.
Methods for Characterization of Alternative RNA Splicing.
Harvey, Samuel E; Cheng, Chonghui
2016-01-01
Quantification of alternative splicing to detect the abundance of differentially spliced isoforms of a gene in total RNA can be accomplished via RT-PCR using both quantitative real-time and semi-quantitative PCR methods. These methods require careful PCR primer design to ensure specific detection of particular splice isoforms. We also describe analysis of alternative splicing using a splicing "minigene" in mammalian cell tissue culture to facilitate investigation of the regulation of alternative splicing of a particular exon of interest.
Buckley, Sean F.; Lane, John W.
2012-01-01
The detection and characterization of subsurface voids plays an important role in the study of karst formations and clandestine tunnels. Horizontal velocity and attenuation tomography (HVAT) using offset‐fan shooting and a towed seismic land streamer is a simple, rapid, minimally invasive method that shows promise for detecting near‐surface voids and providing information on the orientation of linear voids. HVAT surveys were conducted over a known subsurface steam tunnel on the University of Connecticut Depot Campus, Storrs, Connecticut. First‐arrival travel‐time and amplitude data were used to produce two‐dimensional (2D) horizontal (map view) velocity and attenuation tomograms. In addition, attenuation tomograms were produced based on normalized total trace energy (TTE). Both the velocity and TTE attenuation tomograms depict an anomaly consistent with the location and orientation of the known tunnel; the TTE method, however, requires significantly less processing time, and therefore may provide a path forward to semi‐automated, near real‐time detection of near‐surface voids. Further study is needed to assess the utility of the HVAT method to detect deeper voids and the effects of a more complex geology on HVAT results.
NASA Technical Reports Server (NTRS)
Macdonald, H.; Steele, K. (Principal Investigator); Waite, W.; Rice, R.; Shinn, M.; Dillard, T.; Petersen, C.
1977-01-01
The author has identified the following significant results. Comparison between LANDSAT 1 and 2 imagery of Arkansas provided evidence of significant land use changes during the 1972-75 time period. Analysis of Arkansas historical water quality information has shown conclusively that whereas point source pollution generally can be detected by use of water quality data collected by state and federal agencies, sampling methodologies for nonpoint source contamination attributable to surface runoff are totally inadequate. The expensive undertaking of monitoring all nonpoint sources for numerous watersheds can be lessened by implementing LANDSAT change detection analyses.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-09
... activities). Environment/fuel use. Pavement conditions (e.g., snow or ice cover, surface roughness, pothole.../destination pair, by time period, weighted by trip volume. System Throughput is intended to quantify the total.... Pavement conditions such as snow or ice cover, slippery conditions, surface roughness, or pothole detection...
NASA Astrophysics Data System (ADS)
Smirnov, O. Yu.; Agostini, M.; Appel, S.; Bellini, G.; Benziger, J.; Bick, D.; Bonfini, G.; Bravo, D.; Caccianiga, B.; Calaprice, F.; Caminata, A.; Cavalcante, P.; Chepurnov, A.; Choi, K.; D'Angelo, D.; Davini, S.; Derbin, A.; Di Noto, L.; Drachnev, I.; Empl, A.; Etenko, A.; Fomenko, K.; Franco, D.; Gabriele, F.; Galbiati, C.; Ghiano, C.; Giammarchi, M.; Goeger-Neff, M.; Goretti, A.; Gromov, M.; Hagner, C.; Hungerford, E.; Ianni, Aldo; Ianni, Andrea; Jedrzejczak, K.; Kaiser, M.; Kobychev, V.; Korablev, D.; Korga, G.; Kryn, D.; Laubenstein, M.; Lehnert, B.; Litvinovich, E.; Lombardi, F.; Lombardi, P.; Ludhova, L.; Lukyanchenko, G.; Machulin, I.; Manecki, S.; Maneschg, W.; Marcocci, S.; Meroni, E.; Meyer, M.; Miramonti, L.; Misiaszek, M.; Mosteiro, P.; Muratova, V.; Neumair, B.; Oberauer, L.; Obolensky, M.; Ortica, F.; Otis, K.; Pagani, L.; Pallavicini, M.; Papp, L.; Perasso, L.; Pocar, A.; Ranucci, G.; Razeto, A.; Re, A.; Romani, A.; Roncin, R.; Rossi, N.; Schönert, S.; Semenov, D.; Simgen, H.; Skorokhvatov, M.; Sotnikov, A.; Sukhotin, S.; Suvorov, Y.; Tartaglia, R.; Testera, G.; Thurn, J.; Toropova, M.; Unzhakov, E.; Vogelaar, R. B.; von Feilitzsch, F.; Wang, H.; Weinz, S.; Winter, J.; Wojcik, M.; Wurm, M.; Yokley, Z.; Zaimidoroga, O.; Zavatarelli, S.; Zuber, K.; Zuzel, G.
2016-11-01
Neutrino produced in a chain of nuclear reactions in the Sun starting from the fusion of two protons, for the first time has been detected in a real-time detector in spectrometric mode. The unique properties of the Borexino detector provided an oppurtunity to disentangle pp-neutrino spectrum from the background components. A comparison of the total neutrino flux from the Sun with Solar luminosity in photons provides a test of the stability of the Sun on the 105 years time scale, and sets a strong limit on the power production in the unknown energy sources in the Sun of no more than 4% of the total energy production at 90% C.L.
Melendez, Johan H.; Santaus, Tonya M.; Brinsley, Gregory; Kiang, Daniel; Mali, Buddha; Hardick, Justin; Gaydos, Charlotte A.; Geddes, Chris D.
2016-01-01
Nucleic acid-based detection of gonorrhea infections typically require a two-step process involving isolation of the nucleic acid, followed by the detection of the genomic target often involving PCR-based approaches. In an effort to improve on current detection approaches, we have developed a unique two-step microwave-accelerated approach for rapid extraction and detection of Neisseria gonorrhoeae (GC) DNA. Our approach is based on the use of highly-focused microwave radiation to rapidly lyse bacterial cells, release, and subsequently fragment microbial DNA. The DNA target is then detected by a process known as microwave-accelerated metal-enhanced fluorescence (MAMEF), an ultra-sensitive direct DNA detection analytical technique. In the present study, we show that highly focused microwaves at 2.45 GHz, using 12.3 mm gold film equilateral triangles, are able to rapidly lyse both bacteria cells and fragment DNA in a time- and microwave power-dependent manner. Detection of the extracted DNA can be performed by MAMEF, without the need for DNA amplification in less than 10 minutes total time or by other PCR-based approaches. Collectively, the use of a microwave-accelerated method for the release and detection of DNA represents a significant step forward towards the development of a point-of-care (POC) platform for detection of gonorrhea infections. PMID:27325503
Li, L; Roth, R; Germaine, P; Ren, S; Lee, M; Hunter, K; Tinney, E; Liao, L
2017-02-01
The purpose of this study was to retrospectively compare the diagnostic performance of contrast-enhanced spectral mammography (CESM) with that of breast magnetic resonance imaging (BMRI) in breast cancer detection using parameters, including sensitivity, positive predictive value (PPV), lesion size, morphology, lesion and background enhancement, and examination time. A total of 48 women (mean age, 56years±10.6 [SD]) with breast lesions detected between October 2012 and March 2014 were included. Both CESM and BMRI were performed for each patient within 30 days. The enhancement intensity of lesions and breast background parenchyma was subjectively assessed for both modalities and was quantified for comparison. Statistical significance was analyzed using paired t-test for mean size of index lesions in all malignant breasts (an index lesion defined as the largest lesion in each breast), and a mean score of enhancement intensity for index lesions and breast background. PPV, sensitivity, and accuracy were calculated for both CESM and BMRI. The average duration time of CESM and MRI examinations was also compared. A total of 66 lesions were identified, including 62 malignant and 4 benign lesions. Both CESM and BMRI demonstrated a sensitivity of 100% for detection of breast cancer. There was no statistically significant difference between the mean size of index lesions (P=0.108). The enhancement intensity of breast background was significantly lower for CESM than for BMRI (P<0.01). The mean score of enhancement intensity of index lesions on CESM was significantly less than that for BMRI (P<0.01). The smallest lesion that was detected by both modalities measured 4mm. CESM had a higher PPV than BMRI (P>0.05). The average examination time for CESM was significantly shorter than that of BMRI (P<0.01). CESM has similar sensitivity than BMRI in breast cancer detection, with higher PPV and less background enhancement. CESM is associate with significantly shorter exam time thus a more accessible alternative to BMRI, and has the potential to play an important tool in breast cancer detection and staging. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Monitoring cow activity and rumination time for an early detection of heat stress in dairy cow
NASA Astrophysics Data System (ADS)
Abeni, Fabio; Galli, Andrea
2017-03-01
The aim of this study was to explore the use of cow activity and rumination time by precision livestock farming tools as early alert for heat stress (HS) detection. A total of 58 Italian Friesian cows were involved in this study during summer 2015. Based on the temperature humidity index (THI), two different conditions were compared on 16 primiparous and 11 multiparous, to be representative of three lactation phases: early (15-84 DIM), around peak (85-154 DIM), and plateau (155-224 DIM). A separate dataset for the assessment of the variance partition included all the cows in the herd from June 7 to July 16. The rumination time (RT2h, min/2 h) and activity index (AI2h, bouts/2 h) were summarized every 2-h interval. The raw data were used to calculate the following variables: total daily RT (RTt), daytime RT (RTd), nighttime RT (RTn), total daily AI (AIt), daytime AI (AId), and nighttime AI (AIn). Either AIt and AId increased, whereas RTt, RTd, and RTn decreased with higher THI in all the three phases. The highest decrease was recorded for RTd and ranged from 49 % (early) to 45 % (plateau). The contribution of the cow within lactation phase was above 60 % of the total variance for AI traits and a share from 33.9 % (for RTt) to 54.8 % (RTn) for RT traits. These observations must be extended to different feeding managements and different animal genetics to assess if different thresholds could be identified to set an early alert system for the farmer.
NASA Astrophysics Data System (ADS)
Amirkhanian, Varoujan; Tsai, Shou-Kuan
2014-03-01
We introduce a novel and cost-effective capillary gel electrophoresis (CGE) system utilizing disposable pen-shaped gelcartridges for highly efficient, high speed, high throughput fluorescence detection of bio-molecules. The CGE system has been integrated with dual excitation and emission optical-fibers with micro-ball end design for fluorescence detection of bio-molecules separated and detected in a disposable pen-shaped capillary gel electrophoresis cartridge. The high-performance capillary gel electrophoresis (CGE) analyzer has been optimized for glycoprotein analysis type applications. Using commercially available labeling agent such as ANTS (8-aminonapthalene-1,3,6- trisulfonate) as an indicator, the capillary gel electrophoresis-based glycan analyzer provides high detection sensitivity and high resolving power in 2-5 minutes of separations. The system can hold total of 96 samples, which can be automatically analyzed within 4-5 hours. This affordable fiber optic based fluorescence detection system provides fast run times (4 minutes vs. 20 minutes with other CE systems), provides improved peak resolution, good linear dynamic range and reproducible migration times, that can be used in laboratories for high speed glycan (N-glycan) profiling applications. The CGE-based glycan analyzer will significantly increase the pace at which glycoprotein research is performed in the labs, saving hours of preparation time and assuring accurate, consistent and economical results.
Detecting Close-In Extrasolar Giant Planets with the Kepler Photometer via Scattered Light
NASA Astrophysics Data System (ADS)
Jenkins, J. M.; Doyle, L. R.; Kepler Discovery Mission Team
2003-05-01
NASA's Kepler Mission will be launched in 2007 primarily to search for transiting Earth-sized planets in the habitable zones of solar-like stars. In addition, it will be poised to detect the reflected light component from close-in extrasolar giant planets (CEGPs) similar to 51 Peg b. Here we use the DIARAD/SOHO time series along with models for the reflected light signatures of CEGPs to evaluate Kepler's ability to detect such planets. We examine the detectability as a function of stellar brightness, stellar rotation period, planetary orbital inclination angle, and planetary orbital period, and then estimate the total number of CEGPs that Kepler will detect over its four year mission. The analysis shows that intrinsic stellar variability of solar-like stars is a major obstacle to detecting the reflected light from CEGPs. Monte Carlo trials are used to estimate the detection threshold required to limit the total number of expected false alarms to no more than one for a survey of 100,000 stellar light curves. Kepler will likely detect 100-760 51 Peg b-like planets by reflected light with orbital periods up to 7 days. LRD was supported by the Carl Sagan Chair at the Center for the Study of Life in the Universe, a division of the SETI Institute. JMJ received support from the Kepler Mission Photometer and Science Office at NASA Ames Research Center.
Létant, Sonia E.; Murphy, Gloria A.; Alfaro, Teneile M.; Avila, Julie R.; Kane, Staci R.; Raber, Ellen; Bunt, Thomas M.; Shah, Sanjiv R.
2011-01-01
In the event of a biothreat agent release, hundreds of samples would need to be rapidly processed to characterize the extent of contamination and determine the efficacy of remediation activities. Current biological agent identification and viability determination methods are both labor- and time-intensive such that turnaround time for confirmed results is typically several days. In order to alleviate this issue, automated, high-throughput sample processing methods were developed in which real-time PCR analysis is conducted on samples before and after incubation. The method, referred to as rapid-viability (RV)-PCR, uses the change in cycle threshold after incubation to detect the presence of live organisms. In this article, we report a novel RV-PCR method for detection of live, virulent Bacillus anthracis, in which the incubation time was reduced from 14 h to 9 h, bringing the total turnaround time for results below 15 h. The method incorporates a magnetic bead-based DNA extraction and purification step prior to PCR analysis, as well as specific real-time PCR assays for the B. anthracis chromosome and pXO1 and pXO2 plasmids. A single laboratory verification of the optimized method applied to the detection of virulent B. anthracis in environmental samples was conducted and showed a detection level of 10 to 99 CFU/sample with both manual and automated RV-PCR methods in the presence of various challenges. Experiments exploring the relationship between the incubation time and the limit of detection suggest that the method could be further shortened by an additional 2 to 3 h for relatively clean samples. PMID:21764960
Effects of frying and boiling on the formation of heterocyclic amines in braised chicken.
Yao, Y; Peng, Z Q; Shao, B; Wan, K H; Wang, F L; Zhang, Y W; Li, J K; Hui, T
2013-11-01
Braised chicken is a traditional ready-to-eat poultry product produced by frying chicken coated with maltose or honey and then boiling it in a soup that is circularly used. This study examined the effects of the frying time, honey concentration, boiling time, and cycle times of the soup on the formation of heterocyclic amines (HA), a class of mutagenic/carcinogenic compounds generated in heated muscle meat. Nine HA in chicken and recycled soups were analyzed by HPLC with UV and fluorescence detection. 1-Methyl-9H-pyrido[3,4-b]indole (Harman), 9H-pyrido[3,4-b]indole (Norharman), and 3-amino-1,4-dimethyl-5H-pyrido[4,3-b]indole (Trp-P-1) were detected in most samples, and the amount of each HA increased with the frying or boiling time. Chicken skin was found to have higher HA content than chicken meat. More HA were detected in the soup than in the chicken, in most cases. 2-Amino-3-methylimidazo[4,5-f]quinoline and 2-amino-3,4,8-trimethylimidazoquinoxaline (4,8-DiMeIQx) were also detected in chicken and soup circularly boiled 20 times, and the total amount of HA reached 68.80 and 96.98 ng/g in chicken and soup, respectively.
Norbäck, Dan; Cai, Gui-Hong
2011-10-01
There is little information on the indoor environment in hotels. Analysis of fungal DNA by quantitative PCR (qPCR) is a new method which can detect general and specific sequences. Dust was collected through swab sampling of door frames in 69 hotel rooms in 20 countries in Europe and Asia (2007-2009). Five sequences were detected by qPCR: total fungal DNA, Aspergillus and Penicillium DNA (Asp/Pen DNA), Aspergillus versicolor (A. versicolor DNA), Stachybotrys chartarum (S. chartarum DNA) and Streptomyces spp. (Streptomyces DNA). Associations were analysed by multiple linear regression. Total fungal DNA (GM = 1.08 × 10(8) cell equivalents m(-2); GSD = 6.36) and Asp/Pen DNA (GM = 1.79 × 10(7) cell equivalents m(-2); GSD = 10.12) were detected in all rooms. A. versicolor DNA, S. chartarum DNA and Streptomyces DNA were detected in 84%, 28% and 47% of the samples. In total, 20% of the rooms had observed dampness/mould, and 30% had odour. Low latitude (range 1.5-64.2 degrees) was a predictor of Asp/Pen DNA. Seaside location, lack of mechanical ventilation, and dampness or mould were other predictors of total fungal DNA and Asp/Pen DNA. Hotel ranking (Trip Advisor) or self-rated quality of the interior of the hotel room was a predictor of total fungal DNA, A. versicolor DNA and Streptomyces DNA. Odour was a predictor of S. chartarum DNA. In conclusion, fungal DNA in swab samples from hotel rooms was related to latitude, seaside location, ventilation, visible dampness and indoor mould growth. Hotels in tropical areas may have 10-100 times higher levels of common moulds such as Aspergillus and Penicillium species, as compared to a temperate climate zone.
Cunha, S C; Fernandes, J O
2010-11-15
A novel method combining dispersive liquid-liquid microextraction (DLLME) and heart-cutting multidimensional gas chromatography coupled to mass spectrometry was developed for the determination of free and total bisphenol A (BPA) and bisphenol B (BPB) in human urine samples. The DLLME procedure combines extraction, derivatization and concentration of the analytes into one step. Several important variables influencing the extraction efficiency and selectivity such as nature and volume of extractive and dispersive solvents as well as the amount of acetylating reagent were investigated. The temperature and time to hydrolyze BPA and BPB conjugates with a β-glucuronidase and sulfatase enzyme preparation were also studied. Under the optimized conditions good efficiency extraction (71-93%) and acceptable total DLLME yields (56-77%) were obtained for both analytes. Matrix-matched calibration curves were linear with correlation coefficients higher than 0.996 in the range level 0.1-5 μg/l, and the relative standard deviations (%RSD) were lower than 20% (n=6). The limits of detection were 0.03 and 0.05 μg/l for BPA and BPB, respectively. The applicability of the proposed method for determining urinary free and total BPA and BPB was assessed by analyzing the human urine of a group of 20 volunteers. Free BPA was detected in 45% of the sample whereas total BPA was detected in 85% of the samples at concentrations ranging between 0.39 and 4.99 μg/l. BPB was detected in conjugated form in two samples. Copyright © 2010 Elsevier B.V. All rights reserved.
Li, Zhanming; Fu, Yingchun; Fang, Weihuan; Li, Yanbin
2015-01-01
Escherichia coli O157:H7 is a predominant foodborne pathogen with severe pathogenicity, leading to increasing attention given to rapid and sensitive detection. Herein, we propose an impedance biosensor using new kinds of screen-printed interdigitated microelectrodes (SPIMs) and wheat germ agglutinin (WGA) for signal amplification to detect E. coli O157:H7 with high sensitivity and time-efficiency. The SPIMs integrate the high sensitivity and short response time of the interdigitated electrodes and the low cost of the screen-printed electrodes. Self-assembling of bi-functional 3-dithiobis-(sulfosuccinimidyl-propionate) (DTSP) on the SPIMs was investigated and was proved to be able to improve adsorption quantity and stability of biomaterials. WGA was further adopted to enhance the signal taking advantage of the abundant lectin-binding sites on the bacteria surface. The immunosensor exhibited a detection limit of 102 cfu·mL−1, with a linear detection range from 102 to 107 cfu·mL−1 (r2 = 0.98). The total detection time was less than 1 h, showing its comparable sensitivity and rapid response. Furthermore, the low cost of one SPIM significantly reduced the detection cost of the biosensor. The biosensor may have great promise in food safety analysis and lead to a portable biosensing system for routine monitoring of foodborne pathogens. PMID:26251911
NASA Astrophysics Data System (ADS)
Doll, William E.; Bell, David T.; Gamey, T. Jeffrey; Beard, Les P.; Sheehan, Jacob R.; Norton, Jeannemarie
2010-04-01
Over the past decade, notable progress has been made in the performance of airborne geophysical systems for mapping and detection of unexploded ordnance in terrestrial and shallow marine environments. For magnetometer systems, the most significant improvements include development of denser magnetometer arrays and vertical gradiometer configurations. In prototype analyses and recent Environmental Security Technology Certification Program (ESTCP) assessments using new production systems the greatest sensitivity has been achieved with a vertical gradiometer configuration, despite model-based survey design results which suggest that dense total-field arrays would be superior. As effective as magnetometer systems have proven to be at many sites, they are inadequate at sites where basalts and other ferrous geologic formations or soils produce anomalies that approach or exceed those of target ordnance items. Additionally, magnetometer systems are ineffective where detection of non-ferrous ordnance items is of primary concern. Recent completion of the Battelle TEM-8 airborne time-domain electromagnetic system represents the culmination of nearly nine years of assessment and development of airborne electromagnetic systems for UXO mapping and detection. A recent ESTCP demonstration of this system in New Mexico showed that it was able to detect 99% of blind-seeded ordnance items, 81mm and larger, and that it could be used to map in detail a bombing target on a basalt flow where previous airborne magnetometer surveys had failed. The probability of detection for the TEM-8 in the blind-seeded study area was better than that reported for a dense-array total-field magnetometer demonstration of the same blind-seeded site, and the TEM-8 system successfully detected these items with less than half as many anomaly picks as the dense-array total-field magnetometer system.
47 CFR 101.521 - Spectrum utilization.
Code of Federal Regulations, 2010 CFR
2010-10-01
... applicants for DEMS frequencies in the 10.6 GHz band must submit as part of the original application a... contain detailed descriptions of the modulation method, the channel time sharing method, any error detecting and/or correcting codes, any spatial frequency reuse system and the total data throughput capacity...
Suzuki, Kunio; Sakai, D K
2007-03-13
Quantification of msa gene mRNA of Renibacterium salmoninarum, the causative agent of bacterial kidney disease (BKD), was investigated using reverse transcription followed by real-time PCR assay on R. salmoninarum in culture, and in experimentally challenged chum salmon Oncorhynchus keta fry kidney tissues (total of 70 samples) after intraperitoneal (i.p.) injection and bath infection. Correlations of msa gene mRNA concentrations with culturable cell concentrations (as colony forming units [CFU]), determined by drop-plate culture method on selective kidney disease medium (SKDM) agar through a 12 wk incubation time, and msa gene DNA concentrations by real-time PCR assay were examined. Furthermore, ovarian fluid samples from wild chum salmon adults with no clinical signs of disease were collected from 8 rivers and from clinically infected kokanee 0. nerka and masu salmon O. masou that were reared in 1 and 2 hatcheries, respectively (total of 414 samples). All samples were examined by nested PCR assay. Then, positive samples were examined by real-time PCR assays for mRNA and DNA; mRNA was detectable at 8 log units (5.0 x 101 to 5.0 x 10(9) copies p11(-1)) with high correlation (R2 = 0.999). The mRNA concentration correlated with CFU in kidney tissue from fish infected by i.p. injection (R2 = 0.924), by bath infection (R2 = 0.502) and in culture (R2 = 0.888). R. salmoninarum was detected and quantified by real-time PCR assay for mRNA in ovarian fluid samples in both subclinically infected chum salmon adults and clinically infected kokanee and masu salmon adults; detection rates ranged from 0 to 44.4% and concentrations ranged from 9.7 x 10(2) to 5.6 x 10(5) copies pl(-1). These results indicate that real-time PCR assay for the mRNA is a rapid, sensitive and reliable method to detect and quantify the viability of R. salmoninarum in kidney and ovarian fluid samples of salmonid fishes with both clinical and subclinical infection of the pathogen.
Vang, Óluva K; Corfitzen, Charlotte B; Smith, Christian; Albrechtsen, Hans-Jørgen
2014-11-01
Fast and reliable methods are required for monitoring of microbial drinking water quality in order to protect public health. Adenosine triphosphate (ATP) was investigated as a potential real-time parameter for detecting microbial ingress in drinking water contaminated with wastewater or surface water. To investigate the ability of the ATP assay in detecting different contamination types, the contaminant was diluted with non-chlorinated drinking water. Wastewater, diluted at 10(4) in drinking water, was detected with the ATP assay, as well as 10(2) to 10(3) times diluted surface water. To improve the performance of the ATP assay in detecting microbial ingress in drinking water, different approaches were investigated, i.e. quantifying microbial ATP or applying reagents of different sensitivities to reduce measurement variations; however, none of these approaches contributed significantly in this respect. Compared to traditional microbiological methods, the ATP assay could detect wastewater and surface water in drinking water to a higher degree than total direct counts (TDCs), while both heterotrophic plate counts (HPC 22 °C and HPC 37 °C) and Colilert-18 (Escherichia coli and coliforms) were more sensitive than the ATP measurements, though with much longer response times. Continuous sampling combined with ATP measurements displays definite monitoring potential for microbial drinking water quality, since microbial ingress in drinking water can be detected in real-time with ATP measurements. The ability of the ATP assay to detect microbial ingress is influenced by both the ATP load from the contaminant itself and the ATP concentration in the specific drinking water. Consequently, a low ATP concentration of the specific drinking water facilitates a better detection of a potential contamination of the water supply with the ATP assay. Copyright © 2014 Elsevier Ltd. All rights reserved.
He, Shengfa; Li, Xin; Wu, Yong; Wu, Shandong; Wu, Zhihua; Yang, Anshu; Tong, Ping; Yuan, Juanli; Gao, Jinyan; Chen, Hongbing
2018-06-01
Bovine milk is a recognized allergenic food source with β-lactoglobulin (BLG) as its major allergen. Reliable detection of BLG epitopes can, therefore, be a useful marker for the presence of milk in processed food products, and for potential allergenicity. At the present, enzyme-linked immunosorbent assays (ELISA) for the detection of BLG are time-consuming and generally not specific to BLG IgE epitopes. In this study, the 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide-activated anti-BLG IgE epitope monoclonal antibody (mAb 1G9) was covalently bound onto the KOH-treated microtiter plate surface. Using this mAb-bound plate in sandwich combination with biotinylated anti-BLG polyclonal antibody-labeled gold nanoparticles, a linear dynamic range between 31.25 and 64 × 10 3 ng mL -1 with a limit of detection for BLG of 0.49 ng mL -1 was obtained, which is 32 times wider and 16 times more sensitive than conventional sandwich ELISA (sELISA). Total recovery of BLG in spiked food samples was found, without matrix effects. Also in partially hydrolyzed infant formulas, the allergenic BLG residues were detected quantitatively. Compared with conventional and commercial BLG detection sELISAs, our sELISA is reliable, highly BLG epitope-specific, user-friendly, and time-saving and allows accurate detection of potentially allergenic residues in different types of processed foods. This improved sELISA protocol can be easily extended to detect other well-identified and characterized food allergens. Graphical abstract IgE epitope mAb-bound plate in sandwich combination with gold probe for sensitive and rapid detection of bovine β-lactoglobulin and its potentially allergenic residues.
Liang, Shih-Yu; Hsia, Kan-Tai; Chan, Yun-Hsien; Fan, Chia-Kwung; Jiang, Donald Dah-Shyong; Landt, Olfert; Ji, Dar-Der
2010-08-01
A single-tube multiprobe real-time PCR assay for simultaneous detection of Entamoeba histolytica and Entamoeba dispar was developed. One primer pair with 2 species-specific probes was designed based on new SSU RNA regions of the ribosomal DNA-containing episome. The sensitivity is 1 parasite per milliliter of feces and thus superior to the conventional nested PCR and comparable to other published real-time PCR protocols. The applicability for clinical diagnosis was validated with 218 stool specimens from patients. A total of 51 E. histolytica and 39 E. dispar positive samples was detected by the multiprobe real-time PCR compared to 39 and 22 by routine nested PCR diagnosis. The detection rate of Entamoeba species for the multiprobe real-time PCR assays was significantly higher than the nested PCR (40.8% vs. 28.0%, P < 0.01). The test did not show cross reactivity with DNA from Entamoeba moshkovskii, Giardia lamblia , Cryptosporidium sp., Escherichia coli , or other nonpathogenic enteric parasites. The multiprobe real-time PCR assay is simple and rapid and has high specificity and sensitivity. The assay could streamline the laboratory diagnosis procedure and facilitate epidemiological investigation.
Guelfo, Jennifer L; Adamson, David T
2018-05-01
The United States Environmental Protection Agency (USEPA) completed nationwide screening of six perfluoroalkyl substances in U.S. drinking water from 2013 to 2015 under the Third Unregulated Contaminant Monitoring Rule (UCMR3). UCMR3 efforts yielded a dataset of 36,139 samples containing analytical results from >5000 public water systems (PWSs). This study used UCMR3 data to investigate three aspects of per- and polyfluoroalkyl substances (PFASs) in drinking water: the occurrence of PFAS and co-contaminant mixtures, trends in PFAS detections relative to PWS characteristics and potential release types, and temporal trends in PFAS occurrence. This was achieved through bivariate and multivariate analyses including categorical analysis, concentration ratios, and hierarchical cluster analysis. Approximately 50% of samples with PFAS detections contained ≥2 PFASs, and 72% of detections occurred in groundwater. Large PWSs (>10,000 customers) were 5.6 times more likely than small PWSs (≤10,000 customers) to exhibit PFAS detections; however, when detected, median total PFAS concentrations were higher in small PWSs (0.12 μg/L) than in large (0.053 μg/L). Bivariate and multivariate analyses of PFAS composition suggested PWSs reflect impacts due to firefighting foam use and WWTP effluent as compared to other source types for which data were available. Mann-Kendall analysis of quarterly total PFAS detection rates indicated an increasing trend over time (p = 0.03). UCMR3 data provide a foundation for tiered design of targeted sampling and analysis plans to address remaining knowledge gaps in the sources, composition, and concentrations of PFASs in U.S. drinking water. Copyright © 2018 Elsevier Ltd. All rights reserved.
EE Cep Winks in Full Color (Abstract)
NASA Astrophysics Data System (ADS)
Walker, G.
2015-06-01
(Abstract only) We observe the long period (5.6 years) Eclipsing Binary Variable Star EE Cep during its 2014 eclipse. It was observed on every clear night from the Maria Mitchell Observatory as well as remote sites for a total of 25 nights. Each night consisted of a detailed time series in BVRI looking for short term variations for a total of >10,000 observations. The data was transformed to the Standard System. In addition, a time series was captured during the night of the eclipse. This data provides an alternate method to determine Time of Minimum than traditionally performed. The TOM varied with color. Several strong correlations are seen between colors substantiating the detection of variations on a time scale of hours. The long term light curve shows five interesting and different Phases with different characteristics.
NASA Astrophysics Data System (ADS)
Altamirano, D.; Degenaar, N.; Heinke, C. O.; Homan, J.; Pooley, D.; Sivakoff, G. R.; Wijnands, R.
2011-10-01
Following the detection of an X-ray outburst in the direction of Terzan 5 (ATEL #3714), we obtained a Swift observation and additional RXTE observations. The XRT aboard Swift observed Terzan 5 on Oct. 26, 2011 in imaging mode for a total exposure time of 967 s. The source was detected at high count rates causing significant pile-up (the core is saturated), and a bad column intersects the point-spread function.
Diagnostic Yield of Extended Cardiac Patch Monitoring in Patients with Stroke or TIA.
Tung, Christie E; Su, Derek; Turakhia, Mintu P; Lansberg, Maarten G
2014-01-01
It is important to evaluate patients with transient ischemic attack (TIA) or stroke for atrial fibrillation (AF) because the detection of AF changes the recommended anti-thrombotic regimen from treatment with an antiplatelet agent to oral anticoagulation. This study describes the diagnostic yield of a patch-based, single-use, and water-resistant 14-day continuous cardiac rhythm monitor (ZIO Patch) in patients with stroke or TIA. We obtained data from the manufacturer and servicer of the ZIO Patch (iRhythm Technologies). Patients who were monitored between January 2012 and June 2013 and whose indication for monitoring was TIA or stroke were included. The duration of monitoring, the number and type of arrhythmias, and the time to first arrhythmia were documented. One thousand one hundred seventy-one monitoring reports were analyzed. The mean monitor wear time was 10.9 days and the median wear time was 13.0 days (interquartile range 7.2-14.0). The median analyzable time relative to the total wear time was 98.7% (IQR 96.0-99.5%). AF was present in 5.0% of all reports. The mean duration before the first episode of paroxysmal AF (PAF) was 1.5 days and the median duration was 0.4 days. 14.3% of first PAF episodes occurred after 48 h. The mean PAF burden was 12.7% of the total monitoring duration. Excellent quality of the recordings and very good patient compliance coupled with a substantial proportion of AF detection beyond the first 48 h of monitoring suggest that the cardiac patch is superior to conventional 48-h Holter monitors for AF detection in patients with stroke or TIA.
Aktaş, Elif; Otlu, Barış; Erdemir, Duygu; Ekici, Hatice; Bulut, Emin
2017-12-01
We aim to investigate, as a first insight, the presence and rates of high-risk Escherichia coli ST131 clone in Istanbul and evaluate antimicrobial resistance and CTX-M-15 production of ST131 and non-ST131 isolates. The use of MALDI-TOF MS (matrix-assisted laser desorption/ionization time-of-flight mass-spectrometry) to detect E. coli ST131 clone is also evaluated. A total of 203 extended-spectrum beta-lactamase (ESBL)-producing urinary isolates from a training hospital in Istanbul were investigated. Detection of E. coli ST131 was done by MALDI-TOF MS and real-time PCR melting curve analysis. The presence of CTX-M and CTX-M-15 beta-lactamases was investigated by PCR and sequence analysis. Of the 203 isolates, 81 (39.9%) and 75 (36.9%) isolates were identified as ST131 clone by PCR and MALDI-TOF MS, respectively. Resistance to ciprofloxacin was significantly higher among ST131 isolates. A total of 169 (83.5%) isolates produced CTX-M beta-lactamase, of which 72 (43%) were CTX-M-15. The production of CTX-M and CTX-M-15 were significantly higher among ST131 isolates. We have demonstrated, for the first time, high rates of ST131 clone among ESBL-producing E. coli isolates in Istanbul, a region with high rates of resistance to third-generation cephalosporins and fluoroquinolones. Further investigation of this high-risk clone and its contribution to high antimicrobial resistance in Turkey is essential. MALDI-TOF MS is a useful tool for detection of high-risk clones and associated resistance patterns, simultaneous to bacterial identification.
Zhou, Xiaodong; Liu, Xiaoli; Li, Jing; Aprecio, Raydolfo M; Zhang, Wu; Li, Yiming
2015-05-01
The use of saliva as a diagnostic fluid for the evaluation of periodontal health has gained attention recently. Most published real-time PCR assays focused on quantification of bacteria in subgingival plaque, not in saliva. The aims of this study were to develop a real-time PCR assay for quantification of six periodontal pathogens in saliva and to establish a relationship between the amount of DNA (fg) and colony-forming unit (CFU). TaqMan primers/probe sets were used for the detection of Aggregatibacter actinomycetemcomitans (Aa), Eikenella corrodens (Ec), Fusobacterium nucleatum (Fn), Porphyromonas gingivalis (Pg), Prevotella intermedia (Pi), Tannerella forsythia (Tf), and total bacteria. Six periodontal pathogens and total bacteria in saliva from 24 periodontally healthy individuals were determined. The relationship between the amount of DNA (fg) and CFU was established by measuring the concentrations of extracted bacterial DNA and CFU per milliliter of bacteria on agar plates. Fn, Ec, and Pi were detected in all saliva samples, while 58.5, 45.8, and 33.3% were detected for Tf, Pg, and Aa, respectively. Numbers of Ec and Fn in saliva were highly correlated (R(2) = 0.93, P < 0.01). The values of DNA (fg) per CFU ranged from 64 for Ec to 121 for Pg. The real-time PCR assay in combination with the relationship between DNA (fg) and CFU can be used to quantitate periodontal pathogens in saliva and estimate the number of live bacteria (CFU). This real-time PCR assay in combination with the relationship between DNA (fg) and CFU has the potential to be an adjunct in evaluation of periodontal health status.
Sharifdini, Meysam; Mirhendi, Hossein; Ashrafi, Keyhan; Hosseini, Mostafa; Mohebali, Mehdi; Khodadadi, Hossein; Kia, Eshrat Beigom
2015-01-01
This study was performed to evaluate nested polymerase chain reaction (PCR) and real-time PCR methods for detection of Strongyloides stercoralis in fecal samples compared with parasitological methods. A total of 466 stool samples were examined by conventional parasitological methods (formalin ether concentration [FEC] and agar plate culture [APC]). DNA was extracted using an in-house method, and mitochondrial cytochrome c oxidase subunit 1 and 18S ribosomal genes were amplified by nested PCR and real-time PCR, respectively. Among 466 samples, 12.7% and 18.2% were found infected with S. stercoralis by FEC and APC, respectively. DNA of S. stercoralis was detected in 18.9% and 25.1% of samples by real-time PCR and nested PCR, respectively. Considering parasitological methods as the diagnostic gold standard, the sensitivity and specificity of nested PCR were 100% and 91.6%, respectively, and that of real-time PCR were 84.7% and 95.8%, respectively. However, considering sequence analyzes of the selected nested PCR products, the specificity of nested PCR is increased. In general, molecular methods were superior to parasitological methods. They were more sensitive and more reliable in detection of S. stercoralis in comparison with parasitological methods. Between the two molecular methods, the sensitivity of nested PCR was higher than real-time PCR. PMID:26350449
Paci, Eugenio; Miccinesi, Guido; Puliti, Donella; Baldazzi, Paola; De Lisi, Vincenzo; Falcini, Fabio; Cirilli, Claudia; Ferretti, Stefano; Mangone, Lucia; Finarelli, Alba Carola; Rosso, Stefano; Segnan, Nereo; Stracci, Fabrizio; Traina, Adele; Tumino, Rosario; Zorzi, Manuel
2006-01-01
Introduction Excess of incidence rates is the expected consequence of service screening. The aim of this paper is to estimate the quota attributable to overdiagnosis in the breast cancer screening programmes in Northern and Central Italy. Methods All patients with breast cancer diagnosed between 50 and 74 years who were resident in screening areas in the six years before and five years after the start of the screening programme were included. We calculated a corrected-for-lead-time number of observed cases for each calendar year. The number of observed incident cases was reduced by the number of screen-detected cases in that year and incremented by the estimated number of screen-detected cases that would have arisen clinically in that year. Results In total we included 13,519 and 13,999 breast cancer cases diagnosed in the pre-screening and screening years, respectively. In total, the excess ratio of observed to predicted in situ and invasive cases was 36.2%. After correction for lead time the excess ratio was 4.6% (95% confidence interval 2 to 7%) and for invasive cases only it was 3.2% (95% confidence interval 1 to 6%). Conclusion The remaining excess of cancers after individual correction for lead time was lower than 5%. PMID:17147789
Hodiamont, Caspar J.; de Jong, Menno D.; Overmeijer, Hendri P. J.; van den Boogaard, Mandy; Visser, Caroline E.
2014-01-01
Background Microbiological laboratories seek technologically innovative solutions to cope with large numbers of samples and limited personnel and financial resources. One platform that has recently become available is the Kiestra Total Laboratory Automation (TLA) system (BD Kiestra B.V., the Netherlands). This fully automated sample processing system, equipped with digital imaging technology, allows superior detection of microbial growth. Combining this approach with matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MS) (Bruker Daltonik, Germany) is expected to enable more rapid identification of pathogens. Methods Early growth detection by digital imaging using Kiestra TLA combined with MS was compared to conventional methods (CM) of detection. Accuracy and time taken for microbial identification were evaluated for the two methods in 219 clinical blood culture isolates. The possible clinical impact of earlier microbial identification was assessed according to antibiotic treatment prescription. Results Pathogen identification using Kiestra TLA combined with MS resulted in a 30.6 hr time gain per isolate compared to CM. Pathogens were successfully identified in 98.4% (249/253) of all tested isolates. Early microbial identification without susceptibility testing led to an adjustment of antibiotic regimen in 12% (24/200) of patients. Conclusions The requisite 24 hr incubation time for microbial pathogens to reach sufficient growth for susceptibility testing and identification would be shortened by the implementation of Kiestra TLA in combination with MS, compared to the use of CM. Not only can this method optimize workflow and reduce costs, but it can allow potentially life-saving switches in antibiotic regimen to be initiated sooner. PMID:24624346
Rowe, Jeffrey D; Harbertson, James F; Osborne, James P; Freitag, Michael; Lim, Juyun; Bakalinsky, Alan T
2010-02-24
Total protein and protein-associated mannan concentrations were measured, and individual proteins were identified during extraction into model wines over 9 months of aging on the yeast lees following completion of fermentations by seven wine strains of Saccharomyces cerevisiae. In aged wines, protein-associated mannan increased about 6-fold (+/-66%), while total protein only increased 2-fold (+/-20%), which resulted in a significantly greater protein-associated mannan/total protein ratio for three strains. A total of 219 proteins were identified among all wine samples taken over the entire time course. Of the 17 "long-lived" proteins detected in all 9 month samples, 13 were cell wall mannoproteins, and four were glycolytic enzymes. Most cytosolic proteins were not detected after 6 months. Native mannosylated yeast invertase was assayed for binding to wine tannin and was found to have a 10-fold lower affinity than nonglycosylated bovine serum albumin. Enrichment of mannoproteins in the aged model wines implies greater solution stability than other yeast proteins and the possibility that their contributions to wine quality may persist long after bottling.
NASA Astrophysics Data System (ADS)
Abbott, B. P.; Abbott, R.; Abbott, T. D.; Acernese, F.; Ackley, K.; Adams, C.; Adams, T.; Addesso, P.; Adhikari, R. X.; Adya, V. B.; Affeldt, C.; Afrough, M.; Agarwal, B.; Agathos, M.; Agatsuma, K.; Aggarwal, N.; Aguiar, O. D.; Aiello, L.; Ain, A.; Ajith, P.; Allen, B.; Allen, G.; Allocca, A.; Altin, P. A.; Amato, A.; Ananyeva, A.; Anderson, S. B.; Anderson, W. G.; Angelova, S. V.; Antier, S.; Appert, S.; Arai, K.; Araya, M. C.; Areeda, J. S.; Arnaud, N.; Arun, K. G.; Ascenzi, S.; Ashton, G.; Ast, M.; Aston, S. M.; Astone, P.; Atallah, D. V.; Aufmuth, P.; Aulbert, C.; AultONeal, K.; Austin, C.; Avila-Alvarez, A.; Babak, S.; Bacon, P.; Bader, M. K. M.; Bae, S.; Baker, P. T.; Baldaccini, F.; Ballardin, G.; Ballmer, S. W.; Banagiri, S.; Barayoga, J. C.; Barclay, S. E.; Barish, B. C.; Barker, D.; Barkett, K.; Barone, F.; Barr, B.; Barsotti, L.; Barsuglia, M.; Barta, D.; Bartlett, J.; Bartos, I.; Bassiri, R.; Basti, A.; Batch, J. C.; Bawaj, M.; Bayley, J. C.; Bazzan, M.; Bécsy, B.; Beer, C.; Bejger, M.; Belahcene, I.; Bell, A. S.; Berger, B. K.; Bergmann, G.; Bero, J. J.; Berry, C. P. L.; Bersanetti, D.; Bertolini, A.; Betzwieser, J.; Bhagwat, S.; Bhandare, R.; Bilenko, I. A.; Billingsley, G.; Billman, C. R.; Birch, J.; Birney, R.; Birnholtz, O.; Biscans, S.; Biscoveanu, S.; Bisht, A.; Bitossi, M.; Biwer, C.; Bizouard, M. A.; Blackburn, J. K.; Blackman, J.; Blair, C. D.; Blair, D. G.; Blair, R. M.; Bloemen, S.; Bock, O.; Bode, N.; Boer, M.; Bogaert, G.; Bohe, A.; Bondu, F.; Bonilla, E.; Bonnand, R.; Boom, B. A.; Bork, R.; Boschi, V.; Bose, S.; Bossie, K.; Bouffanais, Y.; Bozzi, A.; Bradaschia, C.; Brady, P. R.; Branchesi, M.; Brau, J. E.; Briant, T.; Brillet, A.; Brinkmann, M.; Brisson, V.; Brockill, P.; Broida, J. E.; Brooks, A. F.; Brown, D. A.; Brown, D. D.; Brunett, S.; Buchanan, C. C.; Buikema, A.; Bulik, T.; Bulten, H. J.; Buonanno, A.; Buskulic, D.; Buy, C.; Byer, R. L.; Cabero, M.; Cadonati, L.; Cagnoli, G.; Cahillane, C.; Bustillo, J. Calderón; Callister, T. A.; Calloni, E.; Camp, J. B.; Canepa, M.; Canizares, P.; Cannon, K. C.; Cao, H.; Cao, J.; Capano, C. D.; Capocasa, E.; Carbognani, F.; Caride, S.; Carney, M. F.; Diaz, J. Casanueva; Casentini, C.; Caudill, S.; Cavaglià, M.; Cavalier, F.; Cavalieri, R.; Cella, G.; Cepeda, C. B.; Cerdá-Durán, P.; Cerretani, G.; Cesarini, E.; Chamberlin, S. J.; Chan, M.; Chao, S.; Charlton, P.; Chase, E.; Chassande-Mottin, E.; Chatterjee, D.; Cheeseboro, B. D.; Chen, H. Y.; Chen, X.; Chen, Y.; Cheng, H.-P.; Chia, H.; Chincarini, A.; Chiummo, A.; Chmiel, T.; Cho, H. S.; Cho, M.; Chow, J. H.; Christensen, N.; Chu, Q.; Chua, A. J. K.; Chua, S.; Chung, A. K. W.; Chung, S.; Ciani, G.; Ciolfi, R.; Cirelli, C. E.; Cirone, A.; Clara, F.; Clark, J. A.; Clearwater, P.; Cleva, F.; Cocchieri, C.; Coccia, E.; Cohadon, P.-F.; Cohen, D.; Colla, A.; Collette, C. G.; Cominsky, L. R.; Constancio, M.; Conti, L.; Cooper, S. J.; Corban, P.; Corbitt, T. R.; Cordero-Carrión, I.; Corley, K. R.; Cornish, N.; Corsi, A.; Cortese, S.; Costa, C. A.; Coughlin, M. W.; Coughlin, S. B.; Coulon, J.-P.; Countryman, S. T.; Couvares, P.; Covas, P. B.; Cowan, E. E.; Coward, D. M.; Cowart, M. J.; Coyne, D. C.; Coyne, R.; Creighton, J. D. E.; Creighton, T. D.; Cripe, J.; Crowder, S. G.; Cullen, T. J.; Cumming, A.; Cunningham, L.; Cuoco, E.; Dal Canton, T.; Dálya, G.; Danilishin, S. L.; D'Antonio, S.; Danzmann, K.; Dasgupta, A.; Da Silva Costa, C. F.; Dattilo, V.; Dave, I.; Davier, M.; Davis, D.; Daw, E. J.; Day, B.; De, S.; DeBra, D.; Degallaix, J.; De Laurentis, M.; Deléglise, S.; Del Pozzo, W.; Demos, N.; Denker, T.; Dent, T.; De Pietri, R.; Dergachev, V.; De Rosa, R.; DeRosa, R. T.; De Rossi, C.; DeSalvo, R.; de Varona, O.; Devenson, J.; Dhurandhar, S.; Díaz, M. C.; Di Fiore, L.; Di Giovanni, M.; Di Girolamo, T.; Di Lieto, A.; Di Pace, S.; Di Palma, I.; Di Renzo, F.; Doctor, Z.; Dolique, V.; Donovan, F.; Dooley, K. L.; Doravari, S.; Dorrington, I.; Douglas, R.; Dovale Álvarez, M.; Downes, T. P.; Drago, M.; Dreissigacker, C.; Driggers, J. C.; Du, Z.; Ducrot, M.; Dupej, P.; Dwyer, S. E.; Edo, T. B.; Edwards, M. C.; Effler, A.; Eggenstein, H.-B.; Ehrens, P.; Eichholz, J.; Eikenberry, S. S.; Eisenstein, R. A.; Essick, R. C.; Estevez, D.; Etienne, Z. B.; Etzel, T.; Evans, M.; Evans, T. M.; Factourovich, M.; Fafone, V.; Fair, H.; Fairhurst, S.; Fan, X.; Farinon, S.; Farr, B.; Farr, W. M.; Fauchon-Jones, E. J.; Favata, M.; Fays, M.; Fee, C.; Fehrmann, H.; Feicht, J.; Fejer, M. M.; Fernandez-Galiana, A.; Ferrante, I.; Ferreira, E. C.; Ferrini, F.; Fidecaro, F.; Finstad, D.; Fiori, I.; Fiorucci, D.; Fishbach, M.; Fisher, R. P.; Fitz-Axen, M.; Flaminio, R.; Fletcher, M.; Fong, H.; Font, J. A.; Forsyth, P. W. F.; Forsyth, S. S.; Fournier, J.-D.; Frasca, S.; Frasconi, F.; Frei, Z.; Freise, A.; Frey, R.; Frey, V.; Fries, E. M.; Fritschel, P.; Frolov, V. V.; Fulda, P.; Fyffe, M.; Gabbard, H.; Gadre, B. U.; Gaebel, S. M.; Gair, J. R.; Gammaitoni, L.; Ganija, M. R.; Gaonkar, S. G.; Garcia-Quiros, C.; Garufi, F.; Gateley, B.; Gaudio, S.; Gaur, G.; Gayathri, V.; Gehrels, N.; Gemme, G.; Genin, E.; Gennai, A.; George, D.; George, J.; Gergely, L.; Germain, V.; Ghonge, S.; Ghosh, Abhirup; Ghosh, Archisman; Ghosh, S.; Giaime, J. A.; Giardina, K. D.; Giazotto, A.; Gill, K.; Glover, L.; Goetz, E.; Goetz, R.; Gomes, S.; Goncharov, B.; González, G.; Gonzalez Castro, J. M.; Gopakumar, A.; Gorodetsky, M. L.; Gossan, S. E.; Gosselin, M.; Gouaty, R.; Grado, A.; Graef, C.; Granata, M.; Grant, A.; Gras, S.; Gray, C.; Greco, G.; Green, A. C.; Gretarsson, E. M.; Groot, P.; Grote, H.; Grunewald, S.; Gruning, P.; Guidi, G. M.; Guo, X.; Gupta, A.; Gupta, M. K.; Gushwa, K. E.; Gustafson, E. K.; Gustafson, R.; Halim, O.; Hall, B. R.; Hall, E. D.; Hamilton, E. Z.; Hammond, G.; Haney, M.; Hanke, M. M.; Hanks, J.; Hanna, C.; Hannam, M. D.; Hannuksela, O. A.; Hanson, J.; Hardwick, T.; Harms, J.; Harry, G. M.; Harry, I. W.; Hart, M. J.; Haster, C.-J.; Haughian, K.; Healy, J.; Heidmann, A.; Heintze, M. C.; Heitmann, H.; Hello, P.; Hemming, G.; Hendry, M.; Heng, I. S.; Hennig, J.; Heptonstall, A. W.; Heurs, M.; Hild, S.; Hinderer, T.; Hoak, D.; Hofman, D.; Holt, K.; Holz, D. E.; Hopkins, P.; Horst, C.; Hough, J.; Houston, E. A.; Howell, E. J.; Hreibi, A.; Hu, Y. M.; Huerta, E. A.; Huet, D.; Hughey, B.; Husa, S.; Huttner, S. H.; Huynh-Dinh, T.; Indik, N.; Inta, R.; Intini, G.; Isa, H. N.; Isac, J.-M.; Isi, M.; Iyer, B. R.; Izumi, K.; Jacqmin, T.; Jani, K.; Jaranowski, P.; Jawahar, S.; Jiménez-Forteza, F.; Johnson, W. W.; Jones, D. I.; Jones, R.; Jonker, R. J. G.; Ju, L.; Junker, J.; Kalaghatgi, C. V.; Kalogera, V.; Kamai, B.; Kandhasamy, S.; Kang, G.; Kanner, J. B.; Kapadia, S. J.; Karki, S.; Karvinen, K. S.; Kasprzack, M.; Katolik, M.; Katsavounidis, E.; Katzman, W.; Kaufer, S.; Kawabe, K.; Kéfélian, F.; Keitel, D.; Kemball, A. J.; Kennedy, R.; Kent, C.; Key, J. S.; Khalili, F. Y.; Khan, I.; Khan, S.; Khan, Z.; Khazanov, E. A.; Kijbunchoo, N.; Kim, Chunglee; Kim, J. C.; Kim, K.; Kim, W.; Kim, W. S.; Kim, Y.-M.; Kimbrell, S. J.; King, E. J.; King, P. J.; Kinley-Hanlon, M.; Kirchhoff, R.; Kissel, J. S.; Kleybolte, L.; Klimenko, S.; Knowles, T. D.; Koch, P.; Koehlenbeck, S. M.; Koley, S.; Kondrashov, V.; Kontos, A.; Korobko, M.; Korth, W. Z.; Kowalska, I.; Kozak, D. B.; Krämer, C.; Kringel, V.; Krishnan, B.; Królak, A.; Kuehn, G.; Kumar, P.; Kumar, R.; Kumar, S.; Kuo, L.; Kutynia, A.; Kwang, S.; Lackey, B. D.; Lai, K. H.; Landry, M.; Lang, R. N.; Lange, J.; Lantz, B.; Lanza, R. K.; Lartaux-Vollard, A.; Lasky, P. D.; Laxen, M.; Lazzarini, A.; Lazzaro, C.; Leaci, P.; Leavey, S.; Lee, C. H.; Lee, H. K.; Lee, H. M.; Lee, H. W.; Lee, K.; Lehmann, J.; Lenon, A.; Leonardi, M.; Leroy, N.; Letendre, N.; Levin, Y.; Li, T. G. F.; Linker, S. D.; Littenberg, T. B.; Liu, J.; Lo, R. K. L.; Lockerbie, N. A.; London, L. T.; Lord, J. E.; Lorenzini, M.; Loriette, V.; Lormand, M.; Losurdo, G.; Lough, J. D.; Lousto, C. O.; Lovelace, G.; Lück, H.; Lumaca, D.; Lundgren, A. P.; Lynch, R.; Ma, Y.; Macas, R.; Macfoy, S.; Machenschalk, B.; MacInnis, M.; Macleod, D. M.; Magaña Hernandez, I.; Magaña-Sandoval, F.; Magaña Zertuche, L.; Magee, R. M.; Majorana, E.; Maksimovic, I.; Man, N.; Mandic, V.; Mangano, V.; Mansell, G. L.; Manske, M.; Mantovani, M.; Marchesoni, F.; Marion, F.; Márka, S.; Márka, Z.; Markakis, C.; Markosyan, A. S.; Markowitz, A.; Maros, E.; Marquina, A.; Martelli, F.; Martellini, L.; Martin, I. W.; Martin, R. M.; Martynov, D. V.; Mason, K.; Massera, E.; Masserot, A.; Massinger, T. J.; Masso-Reid, M.; Mastrogiovanni, S.; Matas, A.; Matichard, F.; Matone, L.; Mavalvala, N.; Mazumder, N.; McCarthy, R.; McClelland, D. E.; McCormick, S.; McCuller, L.; McGuire, S. C.; McIntyre, G.; McIver, J.; McManus, D. J.; McNeill, L.; McRae, T.; McWilliams, S. T.; Meacher, D.; Meadors, G. D.; Mehmet, M.; Meidam, J.; Mejuto-Villa, E.; Melatos, A.; Mendell, G.; Mercer, R. A.; Merilh, E. L.; Merzougui, M.; Meshkov, S.; Messenger, C.; Messick, C.; Metzdorff, R.; Meyers, P. M.; Miao, H.; Michel, C.; Middleton, H.; Mikhailov, E. E.; Milano, L.; Miller, A. L.; Miller, B. B.; Miller, J.; Millhouse, M.; Milovich-Goff, M. C.; Minazzoli, O.; Minenkov, Y.; Ming, J.; Mishra, C.; Mitra, S.; Mitrofanov, V. P.; Mitselmakher, G.; Mittleman, R.; Moffa, D.; Moggi, A.; Mogushi, K.; Mohan, M.; Mohapatra, S. R. P.; Montani, M.; Moore, C. J.; Moraru, D.; Moreno, G.; Morriss, S. R.; Mours, B.; Mow-Lowry, C. M.; Mueller, G.; Muir, A. W.; Mukherjee, Arunava; Mukherjee, D.; Mukherjee, S.; Mukund, N.; Mullavey, A.; Munch, J.; Muñiz, E. A.; Muratore, M.; Murray, P. G.; Napier, K.; Nardecchia, I.; Naticchioni, L.; Nayak, R. K.; Neilson, J.; Nelemans, G.; Nelson, T. J. N.; Nery, M.; Neunzert, A.; Nevin, L.; Newport, J. M.; Newton, G.; Ng, K. K. Y.; Nguyen, T. T.; Nichols, D.; Nielsen, A. B.; Nissanke, S.; Nitz, A.; Noack, A.; Nocera, F.; Nolting, D.; North, C.; Nuttall, L. K.; Oberling, J.; O'Dea, G. D.; Ogin, G. H.; Oh, J. J.; Oh, S. H.; Ohme, F.; Okada, M. A.; Oliver, M.; Oppermann, P.; Oram, Richard J.; O'Reilly, B.; Ormiston, R.; Ortega, L. F.; O'Shaughnessy, R.; Ossokine, S.; Ottaway, D. J.; Overmier, H.; Owen, B. J.; Pace, A. E.; Page, J.; Page, M. A.; Pai, A.; Pai, S. A.; Palamos, J. R.; Palashov, O.; Palomba, C.; Pal-Singh, A.; Pan, Howard; Pan, Huang-Wei; Pang, B.; Pang, P. T. H.; Pankow, C.; Pannarale, F.; Pant, B. C.; Paoletti, F.; Paoli, A.; Papa, M. A.; Parida, A.; Parker, W.; Pascucci, D.; Pasqualetti, A.; Passaquieti, R.; Passuello, D.; Patil, M.; Patricelli, B.; Pearlstone, B. L.; Pedraza, M.; Pedurand, R.; Pekowsky, L.; Pele, A.; Penn, S.; Perez, C. J.; Perreca, A.; Perri, L. M.; Pfeiffer, H. P.; Phelps, M.; Piccinni, O. J.; Pichot, M.; Piergiovanni, F.; Pierro, V.; Pillant, G.; Pinard, L.; Pinto, I. M.; Pirello, M.; Pitkin, M.; Poe, M.; Poggiani, R.; Popolizio, P.; Porter, E. K.; Post, A.; Powell, J.; Prasad, J.; Pratt, J. W. W.; Pratten, G.; Predoi, V.; Prestegard, T.; Prijatelj, M.; Principe, M.; Privitera, S.; Prodi, G. A.; Prokhorov, L. G.; Puncken, O.; Punturo, M.; Puppo, P.; Pürrer, M.; Qi, H.; Quetschke, V.; Quintero, E. A.; Quitzow-James, R.; Raab, F. J.; Rabeling, D. S.; Radkins, H.; Raffai, P.; Raja, S.; Rajan, C.; Rajbhandari, B.; Rakhmanov, M.; Ramirez, K. E.; Ramos-Buades, A.; Rapagnani, P.; Raymond, V.; Razzano, M.; Read, J.; Regimbau, T.; Rei, L.; Reid, S.; Reitze, D. H.; Ren, W.; Reyes, S. D.; Ricci, F.; Ricker, P. M.; Rieger, S.; Riles, K.; Rizzo, M.; Robertson, N. A.; Robie, R.; Robinet, F.; Rocchi, A.; Rolland, L.; Rollins, J. G.; Roma, V. J.; Romano, J. D.; Romano, R.; Romel, C. L.; Romie, J. H.; Rosińska, D.; Ross, M. P.; Rowan, S.; Rüdiger, A.; Ruggi, P.; Rutins, G.; Ryan, K.; Sachdev, S.; Sadecki, T.; Sadeghian, L.; Sakellariadou, M.; Salconi, L.; Saleem, M.; Salemi, F.; Samajdar, A.; Sammut, L.; Sampson, L. M.; Sanchez, E. J.; Sanchez, L. E.; Sanchis-Gual, N.; Sandberg, V.; Sanders, J. R.; Sassolas, B.; Sathyaprakash, B. S.; Saulson, P. R.; Sauter, O.; Savage, R. L.; Sawadsky, A.; Schale, P.; Scheel, M.; Scheuer, J.; Schmidt, J.; Schmidt, P.; Schnabel, R.; Schofield, R. M. S.; Schönbeck, A.; Schreiber, E.; Schuette, D.; Schulte, B. W.; Schutz, B. F.; Schwalbe, S. G.; Scott, J.; Scott, S. M.; Seidel, E.; Sellers, D.; Sengupta, A. S.; Sentenac, D.; Sequino, V.; Sergeev, A.; Shaddock, D. A.; Shaffer, T. J.; Shah, A. A.; Shahriar, M. S.; Shaner, M. B.; Shao, L.; Shapiro, B.; Shawhan, P.; Sheperd, A.; Shoemaker, D. H.; Shoemaker, D. M.; Siellez, K.; Siemens, X.; Sieniawska, M.; Sigg, D.; Silva, A. D.; Singer, L. P.; Singh, A.; Singhal, A.; Sintes, A. M.; Slagmolen, B. J. J.; Smith, B.; Smith, J. R.; Smith, R. J. E.; Somala, S.; Son, E. J.; Sonnenberg, J. A.; Sorazu, B.; Sorrentino, F.; Souradeep, T.; Spencer, A. P.; Srivastava, A. K.; Staats, K.; Staley, A.; Steinke, M.; Steinlechner, J.; Steinlechner, S.; Steinmeyer, D.; Stevenson, S. P.; Stone, R.; Stops, D. J.; Strain, K. A.; Stratta, G.; Strigin, S. E.; Strunk, A.; Sturani, R.; Stuver, A. L.; Summerscales, T. Z.; Sun, L.; Sunil, S.; Suresh, J.; Sutton, P. J.; Swinkels, B. L.; Szczepańczyk, M. J.; Tacca, M.; Tait, S. C.; Talbot, C.; Talukder, D.; Tanner, D. B.; Tápai, M.; Taracchini, A.; Tasson, J. D.; Taylor, J. A.; Taylor, R.; Tewari, S. V.; Theeg, T.; Thies, F.; Thomas, E. G.; Thomas, M.; Thomas, P.; Thorne, K. A.; Thrane, E.; Tiwari, S.; Tiwari, V.; Tokmakov, K. V.; Toland, K.; Tonelli, M.; Tornasi, Z.; Torres-Forné, A.; Torrie, C. I.; Töyrä, D.; Travasso, F.; Traylor, G.; Trinastic, J.; Tringali, M. C.; Trozzo, L.; Tsang, K. W.; Tse, M.; Tso, R.; Tsukada, L.; Tsuna, D.; Tuyenbayev, D.; Ueno, K.; Ugolini, D.; Unnikrishnan, C. S.; Urban, A. L.; Usman, S. A.; Vahlbruch, H.; Vajente, G.; Valdes, G.; van Bakel, N.; van Beuzekom, M.; van den Brand, J. F. J.; Van Den Broeck, C.; Vander-Hyde, D. C.; van der Schaaf, L.; van Heijningen, J. V.; van Veggel, A. A.; Vardaro, M.; Varma, V.; Vass, S.; Vasúth, M.; Vecchio, A.; Vedovato, G.; Veitch, J.; Veitch, P. J.; Venkateswara, K.; Venugopalan, G.; Verkindt, D.; Vetrano, F.; Viceré, A.; Viets, A. D.; Vinciguerra, S.; Vine, D. J.; Vinet, J.-Y.; Vitale, S.; Vo, T.; Vocca, H.; Vorvick, C.; Vyatchanin, S. P.; Wade, A. R.; Wade, L. E.; Wade, M.; Walet, R.; Walker, M.; Wallace, L.; Walsh, S.; Wang, G.; Wang, H.; Wang, J. Z.; Wang, W. H.; Wang, Y. F.; Ward, R. L.; Warner, J.; Was, M.; Watchi, J.; Weaver, B.; Wei, L.-W.; Weinert, M.; Weinstein, A. J.; Weiss, R.; Wen, L.; Wessel, E. K.; Weßels, P.; Westerweck, J.; Westphal, T.; Wette, K.; Whelan, J. T.; Whiting, B. F.; Whittle, C.; Wilken, D.; Williams, D.; Williams, R. D.; Williamson, A. R.; Willis, J. L.; Willke, B.; Wimmer, M. H.; Winkler, W.; Wipf, C. C.; Wittel, H.; Woan, G.; Woehler, J.; Wofford, J.; Wong, K. W. K.; Worden, J.; Wright, J. L.; Wu, D. S.; Wysocki, D. M.; Xiao, S.; Yamamoto, H.; Yancey, C. C.; Yang, L.; Yap, M. J.; Yazback, M.; Yu, Hang; Yu, Haocun; Yvert, M.; ZadroŻny, A.; Zanolin, M.; Zelenova, T.; Zendri, J.-P.; Zevin, M.; Zhang, L.; Zhang, M.; Zhang, T.; Zhang, Y.-H.; Zhao, C.; Zhou, M.; Zhou, Z.; Zhu, S. J.; Zhu, X. J.; Zucker, M. E.; Zweizig, J.; LIGO Scientific Collaboration; Virgo Collaboration
2018-03-01
The LIGO Scientific and Virgo Collaborations have announced the event GW170817, the first detection of gravitational waves from the coalescence of two neutron stars. The merger rate of binary neutron stars estimated from this event suggests that distant, unresolvable binary neutron stars create a significant astrophysical stochastic gravitational-wave background. The binary neutron star component will add to the contribution from binary black holes, increasing the amplitude of the total astrophysical background relative to previous expectations. In the Advanced LIGO-Virgo frequency band most sensitive to stochastic backgrounds (near 25 Hz), we predict a total astrophysical background with amplitude ΩGW(f =25 Hz )=1. 8-1.3+2.7×10-9 with 90% confidence, compared with ΩGW(f =25 Hz )=1. 1-0.7+1.2×10-9 from binary black holes alone. Assuming the most probable rate for compact binary mergers, we find that the total background may be detectable with a signal-to-noise-ratio of 3 after 40 months of total observation time, based on the expected timeline for Advanced LIGO and Virgo to reach their design sensitivity.
Real-time detection of neurite outgrowth using microfluidic device
NASA Astrophysics Data System (ADS)
Kim, Samhwan; Jang, Jongmoon; Choi, Hongsoo; Moon, Cheil
2013-05-01
We developed a simple method for real-time detection of the neurite outgrowth using microfluidic device. Our microfluidic device contains three compartmentalized channels which are for cell seeding, hydrogel and growth factors. Collagen gel is filled in the middle channel and pheochromocytoma (PC12) cells are seeded in the left channel. To induce differentiation of PC12 cells, 50 ng/ml to1000 ng/ml of nerve growth factor (NGF) is introduced into the right channel. After three days of NGF treatment, PC12 cells begin to extend neurites and formed neurite network from sixth day. Quantification of neurite outgrowth is analyzed by measuring the total area of neurites. On sixth day, the area is doubled compared to the area on third day and increases by 20 times on ninth day.
Increased efficacy for in-house validation of real-time PCR GMO detection methods.
Scholtens, I M J; Kok, E J; Hougs, L; Molenaar, B; Thissen, J T N M; van der Voet, H
2010-03-01
To improve the efficacy of the in-house validation of GMO detection methods (DNA isolation and real-time PCR, polymerase chain reaction), a study was performed to gain insight in the contribution of the different steps of the GMO detection method to the repeatability and in-house reproducibility. In the present study, 19 methods for (GM) soy, maize canola and potato were validated in-house of which 14 on the basis of an 8-day validation scheme using eight different samples and five on the basis of a more concise validation protocol. In this way, data was obtained with respect to the detection limit, accuracy and precision. Also, decision limits were calculated for declaring non-conformance (>0.9%) with 95% reliability. In order to estimate the contribution of the different steps in the GMO analysis to the total variation variance components were estimated using REML (residual maximum likelihood method). From these components, relative standard deviations for repeatability and reproducibility (RSD(r) and RSD(R)) were calculated. The results showed that not only the PCR reaction but also the factors 'DNA isolation' and 'PCR day' are important factors for the total variance and should therefore be included in the in-house validation. It is proposed to use a statistical model to estimate these factors from a large dataset of initial validations so that for similar GMO methods in the future, only the PCR step needs to be validated. The resulting data are discussed in the light of agreed European criteria for qualified GMO detection methods.
Real-time PCR using SYBR Green for the detection of Shigella spp. in food and stool samples.
Mokhtari, W; Nsaibia, S; Gharbi, A; Aouni, M
2013-02-01
Shigella spp are exquisitely fastidious Gram negative organisms that frequently get missed in the detection by traditional culture methods. For this reason, this work has adapted a classical PCR for detection of Shigella in food and stool specimens to real-time PCR using the SYBR Green format. This method follows a melting curve analysis to be more rapid and provide both qualitative and quantitative data about the targeted pathogen. A total of 117 stool samples with diarrhea and 102 food samples were analyzed in Public Health Regional Laboratory of Nabeul by traditional culture methods and real-time PCR. To validate the real-time PCR assay, an experiment was conducted with both spiked and naturally contaminated stool samples. All Shigella strains tested were ipaH positive and all non-Shigella strains yielded no amplification products. The melting temperature (T(m) = 81.5 ± 0.5 °C) was consistently specific for the amplicon. Correlation coefficients of standard curves constructed using the quantification cycle (C(q)) versus copy numbers of Shigella showed good linearity (R² = 0.995; slope = 2.952) and the minimum level of detection was 1.5 × 10³ CFU/g feces. All food samples analyzed were negative for Shigella by standard culture methods, whereas ipaH was detected in 8.8% culture negative food products. Moreover, the ipaH specific PCR system increased the detection rate over that by culture alone from 1.7% to 11.1% among patients with diarrhea. The data presented here shows that the SYBR Green I was suitable for use in the real-time PCR assay, which provided a specific, sensitive and efficient method for the detection and quantification of Shigella spp in food and stool samples. Copyright © 2012 Elsevier Ltd. All rights reserved.
Chen, Huang-Han; Wu, Chih-Hsing; Tsai, Mei-Ling; Huang, Yi-Jing; Chen, Shu-Hui
2012-10-16
The percentage of glycosylated hemoglobin A1c (%GHbA1c) in human whole blood indicates the average plasma glucose concentration over a prolonged period of time and is used to diagnose diabetes. However, detecting GHbA1c in the whole blood using immunoassays has limited detection sensitivity due to its low percentage in total hemoglobin (tHb) and interference from various glycan moieties in the sample. We have developed a sandwich immunoassay using an antibody microarray on a polydimethylsiloxane (PDMS) substrate modified with fluorinated compounds to detect tHb and glycosylated hemoglobin A1c (GHbA1c) in human whole blood without sample pretreatment. A polyclonal antibody against hemoglobin (Hb) immobilized on PDMS is used as a common capture probe to enrich all forms of Hb followed by detection via monoclonal anti-Hb and specific monoclonal anti-GHbA1c antibodies for tHb and GHbA1c detection, respectively. This method prevents the use of glycan binding molecules and dramatically reduces the background interference, yielding a detection limit of 3.58 ng/mL for tHb and 0.20 ng/mL for GHbA1c. The fluorinated modification on PDMS is superior to the glass substrate and eliminates the need for the blocking step which is required in commercial enzyme linked immunosorbent assay (ELISA) kits. Moreover, the detection sensitivity for GHbA1c is 4-5 orders of magnitude higher, but the required sample amount is 25 times less than the commercial method. On the basis of patient sample data, a good linear correlation between %GHbA1c values determined by our method and the certified high performance liquid chromatography (HPLC) standard method is shown with R(2) > 0.98, indicating the great promise of the developed method for clinical applications.
Automatic detection of cardiac cycle and measurement of the mitral annulus diameter in 4D TEE images
NASA Astrophysics Data System (ADS)
Graser, Bastian; Hien, Maximilian; Rauch, Helmut; Meinzer, Hans-Peter; Heimann, Tobias
2012-02-01
Mitral regurgitation is a wide spread problem. For successful surgical treatment quantification of the mitral annulus, especially its diameter, is essential. Time resolved 3D transesophageal echocardiography (TEE) is suitable for this task. Yet, manual measurement in four dimensions is extremely time consuming, which confirms the need for automatic quantification methods. The method we propose is capable of automatically detecting the cardiac cycle (systole or diastole) for each time step and measuring the mitral annulus diameter. This is done using total variation noise filtering, the graph cut segmentation algorithm and morphological operators. An evaluation took place using expert measurements on 4D TEE data of 13 patients. The cardiac cycle was detected correctly on 78% of all images and the mitral annulus diameter was measured with an average error of 3.08 mm. Its full automatic processing makes the method easy to use in the clinical workflow and it provides the surgeon with helpful information.
Xin, Xia; Wan, Yinglang; Wang, Wenjun; Yin, Guangkun; McLamore, Eric S; Lu, Xinxiong
2013-10-28
Quantifying seed viability is required for seed bank maintenance. The classical methods for detecting seed viability are time consuming and frequently cause seed damage and unwanted germination. We have established a novel micro-optrode technique (MOT) to measure seed viability in a quick and non-invasive manner by measuring the oxygen influxes of intact seeds, approximately 10 seconds to screen one seed. Here, we used soybean, wheat, and oilseed rape as models to test our method. After 3-hour imbibition, oxygen influxes were recorded in real-time with the total measurement taking less than 5 minutes. The results indicated a significantly positive correlation between oxygen influxes and viability in all 3 seed types. We also established a linear equation between oxygen influxes and seed viability for each seed type. For measurements, seeds were kept in the early imbibition stage without germination. Thus, MOT is a reliable, quick, and low-cost seed viability detecting technique.
Yin, Jiandong; Sun, Hongzan; Yang, Jiawen; Guo, Qiyong
2014-01-01
The arterial input function (AIF) plays a crucial role in the quantification of cerebral perfusion parameters. The traditional method for AIF detection is based on manual operation, which is time-consuming and subjective. Two automatic methods have been reported that are based on two frequently used clustering algorithms: fuzzy c-means (FCM) and K-means. However, it is still not clear which is better for AIF detection. Hence, we compared the performance of these two clustering methods using both simulated and clinical data. The results demonstrate that K-means analysis can yield more accurate and robust AIF results, although it takes longer to execute than the FCM method. We consider that this longer execution time is trivial relative to the total time required for image manipulation in a PACS setting, and is acceptable if an ideal AIF is obtained. Therefore, the K-means method is preferable to FCM in AIF detection.
Yin, Jiandong; Sun, Hongzan; Yang, Jiawen; Guo, Qiyong
2014-01-01
The arterial input function (AIF) plays a crucial role in the quantification of cerebral perfusion parameters. The traditional method for AIF detection is based on manual operation, which is time-consuming and subjective. Two automatic methods have been reported that are based on two frequently used clustering algorithms: fuzzy c-means (FCM) and K-means. However, it is still not clear which is better for AIF detection. Hence, we compared the performance of these two clustering methods using both simulated and clinical data. The results demonstrate that K-means analysis can yield more accurate and robust AIF results, although it takes longer to execute than the FCM method. We consider that this longer execution time is trivial relative to the total time required for image manipulation in a PACS setting, and is acceptable if an ideal AIF is obtained. Therefore, the K-means method is preferable to FCM in AIF detection. PMID:24503700
Distributing entanglement and single photons through an intra-city, free-space quantum channel.
Resch, K; Lindenthal, M; Blauensteiner, B; Böhm, H; Fedrizzi, A; Kurtsiefer, C; Poppe, A; Schmitt-Manderbach, T; Taraba, M; Ursin, R; Walther, P; Weier, H; Weinfurter, H; Zeilinger, A
2005-01-10
We have distributed entangled photons directly through the atmosphere to a receiver station 7.8 km away over the city of Vienna, Austria at night. Detection of one photon from our entangled pairs constitutes a triggered single photon source from the sender. With no direct time-stable connection, the two stations found coincidence counts in the detection events by calculating the cross-correlation of locally-recorded time stamps shared over a public internet channel. For this experiment, our quantum channel was maintained for a total of 40 minutes during which time a coincidence lock found approximately 60000 coincident detection events. The polarization correlations in those events yielded a Bell parameter, S=2.27+/-0.019, which violates the CHSH-Bell inequality by 14 standard deviations. This result is promising for entanglement-based freespace quantum communication in high-density urban areas. It is also encouraging for optical quantum communication between ground stations and satellites since the length of our free-space link exceeds the atmospheric equivalent.
Rodda, Gordon H.; Dean-Bradley, Kathryn; Campbell, Earl W.; Fritts, Thomas H.; Lardner, Bjorn; Yackel Adams, Amy A.; Reed, Robert N.
2015-01-01
To obtain quantitative information about population dynamics from counts of animals, the per capita detectabilities of each species must remain constant over the course of monitoring. We characterized lizard detection constancy for four species over 17 yr from a single site in northern Guam, a relatively benign situation because detection was relatively easy and we were able to hold constant the site, habitat type, species, season, and sampling method. We monitored two species of diurnal terrestrial skinks (Carlia ailanpalai [Curious Skink], Emoia caeruleocauda [Pacific Bluetailed Skink]) using glueboards placed on the ground in the shade for 3 h on rainless mornings, yielding 10,286 skink captures. We additionally monitored two species of nocturnal arboreal geckos (Hemidactylus frenatus [Common House Gecko]; Lepidodactylus lugubris [Mourning Gecko]) on the basis of 15,212 sightings. We compared these count samples to a series of complete censuses we conducted from four or more total removal plots (everything removed to mineral soil) totaling 400 m2(about 1% of study site) in each of the years 1995, 1999, and 2012, providing time-stamped quantification of detectability for each species. Unfortunately, the actual population trajectories taken by the four species were masked by unexplained variation in detectability. This observation of debilitating latent variability in lizard detectability under nearly ideal conditions undercuts our trust in population estimation techniques that fail to quantify venue-specific detectability, rely on pooled detection probability estimates, or assume that modulation in predefined environmental covariates suffices for estimating detectability.
Keeler, R F; Gross, R
1980-01-01
The total alkaloid and anagyrine contents of bitter and sweet Lupinus luteus, Lupinus angustifolius, Lupinus albus, Lupinus mutabilis, Lupinus polyphyllus, and Lupinus perennis were analyzed by gas chromatography (GC) and mass spectrometry. No anagyrine was detected in any of the samples. The GC peak in some of the samples which corresponded to anagyrine in retention of time seems to be identical to 17-oxolupanine. The alkaloid content of samples ranged from 3.17 to 0.003 percent.
1999-07-01
medium only, LPS (100 ng/ml), or paclitaxel (35 ^iM), concentrations found to induce maximal levels of mRNA in murine macrophages. Total RNA was...not detected in RNA derived from the DA-3 cells over an 8 h timecourse, even after 40 cycles of PCR amplification, without or with treatment...indicated times after stimulation with LPS or paclitaxel. Isolation of total cellular RNA . For in vitro experiments, culture supematants were removed
Prescott, Meagan A; Reed, Aimee N; Jin, Ling; Pastey, Manoj K
2016-09-01
Since the emergence of cyprinid herpesvirus 3 (CyHV-3), outbreaks have been devastating to Common Carp Cyprinus carpio and koi (a variant of Common Carp), leading to high economic losses. Current diagnostics for detecting CyHV-3 are limited in sensitivity and are further complicated by latency. Here we describe the detection of CyHV-3 by recombinase polymerase amplification (RPA). The RPA assay can detect as low as 10 copies of the CyHV-3 genome by an isothermal reaction and yields results in approximately 20 min. Using the RPA assay, the CyHV-3 genome can be detected in the total DNA of white blood cells isolated from koi latently infected with CyHV-3, while less than 10% of the latently infected koi can be detected by a real-time PCR assay in the total DNA of white blood cells. In addition, RPA products can be detected in a lateral flow device that is cheap and fast and can be used outside of the diagnostic lab. The RPA assay and lateral flow device provide for the rapid, sensitive, and specific amplification of CyHV-3 that with future modifications for field use and validation could lead to enhanced surveillance and early diagnosis of CyHV-3 in the laboratory and field. Received September 14, 2015; accepted April 9, 2016.
Guion, Chase E; Ochoa, Theresa J; Walker, Christopher M; Barletta, Francesca; Cleary, Thomas G
2008-05-01
Diarrheagenic Escherichia coli strains are important causes of diarrhea in children from the developing world and are now being recognized as emerging enteropathogens in the developed world. Current methods of detection are too expensive and labor-intensive for routine detection of these organisms to be practical. We developed a real-time fluorescence-based multiplex PCR for the detection of all six of the currently recognized classes of diarrheagenic E. coli. The primers were designed to specifically amplify eight different virulence genes in the same reaction: aggR for enteroaggregative E. coli, stIa/stIb and lt for enterotoxigenic E. coli, eaeA for enteropathogenic E. coli and Shiga toxin-producing E. coli (STEC), stx(1) and stx(2) for STEC, ipaH for enteroinvasive E. coli, and daaD for diffusely adherent E. coli (DAEC). Eighty-nine of ninety diarrheagenic E. coli and 36/36 nonpathogenic E. coli strains were correctly identified using this approach (specificity, 1.00; sensitivity, 0.99). The single false negative was a DAEC strain. The total time between preparation of DNA from E. coli colonies on agar plates and completion of PCR and melting-curve analysis was less than 90 min. The cost of materials was low. Melting-point analysis of real-time multiplex PCR is a rapid, sensitive, specific, and inexpensive method for detection of diarrheagenic E. coli.
Li, Ying; Xuan, Jie; Song, Yujun; Qi, Wenjin; He, Bangshun; Wang, Ping; Qin, Lidong
2016-01-26
Point-of-care (POC) testing has the potential to enable rapid, low-cost, and large-scale screening. POC detection of a multiplexed biomarker panel can facilitate the early diagnosis of non-small cell lung cancer (NSCLC) and, thus, may allow for more timely surgical intervention for life-saving treatment. Herein, we report the nanoporous glass (NPG) integrated volumetric bar-chart chip (V-Chip) for POC detection of the three NSCLC biomarkers CEA, CYFRA 21-1, and SCCA, by the naked eye. The 3D nanostructures in the NPG membrane efficiently increase the number of binding sites for antibodies and decrease the diffusion distance between antibody and antigen, enabling the low detection limit and rapid analysis time of the NPG-V-Chip. We utilized the NPG-V-Chip to test the NSCLC biomarker panel and found that the limit of detection can reach 50 pg/mL (10-fold improvement over the original V-Chip), and the total assay time can be decreased from 4 to 0.5 h. We then detected CEA in 21 serum samples from patients with common cancers, and the on-chip results showed good correlation with the clinical results. We further assayed 10 lung cancer samples using the device and confirmed the results obtained using conventional ELISA methods. In summary, the NPG-V-Chip platform has the ability of multiplex, low detection limit, low cost, lack of need for accessory equipment, and rapid analysis time, which may render the V-Chip a useful platform for quantitative POC detection in resource-limited settings and personalized diagnostics.
Sizirici, Banu; Tansel, Berrin
2010-01-01
The purpose of this study was to evaluate suitability of using the time series analysis for selected leachate quantity and quality parameters to forecast the duration of post closure period of a closed landfill. Selected leachate quality parameters (i.e., sodium, chloride, iron, bicarbonate, total dissolved solids (TDS), and ammonium as N) and volatile organic compounds (VOCs) (i.e., vinyl chloride, 1,4-dichlorobenzene, chlorobenzene, benzene, toluene, ethyl benzene, xylenes, total BTEX) were analyzed by the time series multiplicative decomposition model to estimate the projected levels of the parameters. These parameters were selected based on their detection levels and consistency of detection in leachate samples. In addition, VOCs detected in leachate and their chemical transformations were considered in view of the decomposition stage of the landfill. Projected leachate quality trends were analyzed and compared with the maximum contaminant level (MCL) for the respective parameters. Conditions that lead to specific trends (i.e., increasing, decreasing, or steady) and interactions of leachate quality parameters were evaluated. Decreasing trends were projected for leachate quantity, concentrations of sodium, chloride, TDS, ammonia as N, vinyl chloride, 1,4-dichlorobenzene, benzene, toluene, ethyl benzene, xylenes, and total BTEX. Increasing trends were projected for concentrations of iron, bicarbonate, and chlorobenzene. Anaerobic conditions in landfill provide favorable conditions for corrosion of iron resulting in higher concentrations over time. Bicarbonate formation as a byproduct of bacterial respiration during waste decomposition and the lime rock cap system of the landfill contribute to the increasing levels of bicarbonate in leachate. Chlorobenzene is produced during anaerobic biodegradation of 1,4-dichlorobenzene, hence, the increasing trend of chlorobenzene may be due to the declining trend of 1,4-dichlorobenzene. The time series multiplicative decomposition model in general provides an adequate forecast for future planning purposes for the parameters monitored in leachate. The model projections for 1,4-dichlorobenzene were relatively less accurate in comparison to the projections for vinyl chloride and chlorobenzene. Based on the trends observed, future monitoring needs for the selected leachate parameters were identified.
MOnthly TEmperature DAtabase of Spain 1951-2010: MOTEDAS. (1) Quality control
NASA Astrophysics Data System (ADS)
Peña-Angulo, Dhais; Cortesi, Nicola; Simolo, Claudia; Stepanek, Peter; Brunetti, Michele; González-Hidalgo, José Carlos
2014-05-01
The HIDROCAES project (Impactos Hidrológicos del Calentamiento Global en España, Spanish Ministery of Research CGL2011-27574-C02-01) is focused on the high resolution in the Spanish continental land of the warming processes during the 1951-2010. To do that the Department of Geography (University of Zaragoza, Spain), the Hydrometeorological Service (Brno Division, Chezck Republic) and the ISAC-CNR (Bologna, Italy) are developing the new dataset MOTEDAS (MOnthly TEmperature DAtabase of Spain), from which we present a collection of poster to show (1) the general structure of dataset and quality control; (2) the analyses of spatial correlation of monthly mean values of maximum (Tmax) and minimum (Tmin temperature; (3) the reconstruction processes of series and high resolution grid developing; (4) the first initial results of trend analyses of annual, seasonal and monthly range mean values. MOTEDAS has been created after exhaustive analyses and quality control of the original digitalized data of the Spanish National Meteorological Agency (Agencia Estatal de Meteorología, AEMET). Quality control was applied without any prior reconstruction, i.e. on original series. Then, from the total amount of series stored at AEMet archives (more than 4680) we selected only those series with at least 10 years of data (i.e. 120 months, 3066 series) to apply a quality control and reconstruction processes (see Poster MOTEDAS 3). Length of series was Tmin, upper and lower thresholds of absolute data, etc), and by comparison with reference series (see Poster MOTEDAS 3, about reconstruction). Anomalous data were considered when difference between Candidate and Reference series were higher than three times the interquartile distance. The total amount of monthly suspicious data recognized and discarded at the end of this analyses was 7832 data for Tmin, and 8063 for Tmax data; they represent less than 0,8% of original total monthly data, for both Tmax and Tmin. No spatial pattern was detected in the suspicious data; month by month Tmin shows maximum detection in summer months, while Tmax does not show any monthly pattern. Secondly, the homogeneity analyses was performed on the list of series free of anomalous data by using an arrays of test (SNHT, Bivariate, T de Student and Pettit) after new reference series calculated with data free of anomalous. The tests were applied at monthly, seasonal and annual scale (i.e. 17 times per method). Statistical inhomogeneity detections were accepted as follows: Three annual detections (monthly, seasonal, annual) must be found in SNHT or Bivariate test. The total amount of detections by the four tests was greater than 5% of the total possible detection per year. Before any correction we examined the Candidate and reference series chart. Proclim and Anclim software were used during all the processes The total amount of series affected by inhomogeneities was 1013 (Tmax) and 1011 (Tmin), i.e. 1/3 of original series was considered as inhomogeneous. We notice that identified inhomogeneous series in Tmax and Tmin usually do not coincide. This apparently small amount of series compared with previous work could be originated because of the mean length of series is around 15-20 years. References. Stepánek P. 2008a. AnClim - software for time series analysis (for Windows 95/NT). Department of Geography, Faculty of Natural Sciences, MU, Brno, 1.47 B. Stepánek P.. 2008b. ProClimDB - Software for Processing Climatological Datasets. CHMI, Regional office, Brno.
Le, Nam Cao Hoai; Yokokawa, Ryuji; Dao, Dzung Viet; Nguyen, Thien Duy; Wells, John C; Sugiyama, Susumu
2009-01-21
A poly(dimethylsiloxane) (PDMS) chip for Total Internal Reflection (TIR)-based imaging and detection has been developed using Si bulk micromachining and PDMS casting. In this paper, we report the applications of the chip on both inverted and upright fluorescent microscopes and confirm that two types of sample delivery platforms, PDMS microchannel and glass microchannel, can be easily integrated depending on the magnification of an objective lens needed to visualize a sample. Although any device configuration can be achievable, here we performed two experiments to demonstrate the versatility of the microfluidic TIR-based devices. The first experiment was velocity measurement of Nile red microbeads with nominal diameter of 500 nm in a pressure-driven flow. The time-sequenced fluorescent images of microbeads, illuminated by an evanescent field, were cross-correlated by a Particle Image Velocimetry (PIV) program to obtain near-wall velocity field of the microbeads at various flow rates from 500 nl/min to 3000 nl/min. We then evaluated the capabilities of the device for Single Molecule Detection (SMD) of fluorescently labeled DNA molecules from 30 bp to 48.5 kbp and confirm that DNA molecules as short as 1105 bp were detectable. Our versatile, integrated device could provide low-cost and fast accessibility to Total Internal Reflection Fluorescent Microscopy (TIRFM) on both conventional upright and inverted microscopes. It could also be a useful component in a Micro-Total Analysis System (micro-TAS) to analyze nanoparticles or biomolecules near-wall transport or motion.
Spurlock, F.; Burow, K.; Dubrovsky, N.
2000-01-01
Simazine, diuron, and bromacil are the most frequently detected currently registered pesticides in California groundwater. These herbicides have been used for several decades in Fresno and Tulare counties, California; however, previous data are inadequate to determine whether the detections are a result of recent or historical applications (i.e., within the last decade, or 20-30 yr ago). Chlorofluorocarbon (CFC) groundwater age-dating was used in conjunction with one-dimensional transport modeling to address this question. The estimated times between herbicide application and subsequent detection in groundwater samples from 18 domestic wells ranged from 3 to 33 yr; the aggregate data indicate that more than half of the detections are associated with applications in the last decade. The data also suggest that changes in groundwater quality arising from modified management practices will probably not be discernible for at least a decade. A secondary objective of this study was to evaluate the contribution of simazine degradates deethylsimazine (DES; 2-amino-4-chloro-6-ethylamino-s-triazine) and diaminochlorotriazine (DACT; 2,4-diamino-6-chloro-s-triazine) to total triazine concentrations (defined here as simazine + DES + DACT) in 30 domestic wells. The N-dealkylated s- chlorotriazine degradates DES and DACT substantially contribute to total triazine concentrations in Fresno and Tulare County groundwater, composing 24 to 100% of the total triazines, with a median of 82%. If s-chlorotriazines display a common mode of toxicological action, the prevalence of triazine degradates in water samples found in this and other studies indicate that drinking water standards based on total s-chlorotriazine concentrations may be most appropriate.
Cook, David W; Bowers, John C; DePaola, Angelo
2002-12-01
The densities of total and pathogenic Vibrio parahaemolyticus in 671 samples of molluscan shellfish harvested in 1999 and 2000 from 14 sites in seven Gulf and Atlantic coast states were determined at 2-week intervals over a period of 12 to 16 months in each state. Changes in V. parahaemolyticus densities in shellfish between harvest and sample analysis were minimized with time and temperature controls. Densities were measured by direct plating techniques, and gene probes were used for identification. Total and pathogenic V. parahaemolyticus organisms were identified with probes for the thermolabile direct hemolysin (tlh) gene and the thermostable direct hemolysin (tdh) gene, respectively. An enrichment procedure involving 25 g of shellfish was also used for the recovery of pathogenic V. parahaemolyticus. The densities of V. parahaemolyticus in shellfish from all harvest sites were positively correlated with water temperature. Shellfish from the Gulf Coast typically had higher densities of V. parahaemolyticus than did shellfish harvested from the North Atlantic or mid-Atlantic coast. Vibrio parahaemolyticus counts exceeded 1,000 CFU/g for only 5% of all samples. Pathogenic (tdh+) V. parahaemolyticus was detected in approximately 6% of all samples by both procedures, and 61.5% of populations in the positive samples from the direct plating procedure were at the lower limit of detection (10 CFU/g). The frequency of detection of pathogenic V. parahaemolyticus was significantly related to water temperature and to the density of total V. parahaemolyticus. The failure to detect pathogenic V. parahaemolyticus in shellfish more frequently was attributed to the low numbers and uneven distribution of the organism.
Dai, Fengying; Zhang, Miao; Xu, Dixin; Yang, Yin; Wang, Jiaxiao; Li, Mingzhen; Du, Meihong
2017-11-01
Micro- and nanoimmunomagnetic beads (MIMBs and NIMBs) used for immunomagnetic separation (IMS) with PCR were studied for the rapid detection of Salmonella. The capture efficiency of the two different IMBs was evaluated by a conventional plate counting method, and the binding pattern was studied using scanning electron microscopy. The specificity of the IMBs was tested with Salmonella, Shigella flexneri, enterohemorrhagic Escherichia coli O157:H7, and Listeria monocytogenes. By comparing the pre-enrichment IMS and the IMS enrichment steps with a 5.5-H enrichment time, this study developed a rapid and sensitive method for the detection of Salmonella in chicken. The method was implemented by IMS enrichment and PCR with MIMBs and NIMBs, with a total analysis time of 8 H. We showed that the method was sensitive based on NIMBs with a detection limit of 10° CFU for Salmonella in 25 g of chicken. © 2016 International Union of Biochemistry and Molecular Biology, Inc.
A Real-Time Earthquake Precursor Detection Technique Using TEC from a GPS Network
NASA Astrophysics Data System (ADS)
Alp Akyol, Ali; Arikan, Feza; Arikan, Orhan
2016-07-01
Anomalies have been observed in the ionospheric electron density distribution prior to strong earthquakes. However, most of the reported results are obtained by earthquake analysis. Therefore, their implementation in practice is highly problematic. Recently, a novel earthquake precursor detection technique based on spatio-temporal analysis of Total Electron Content (TEC) data obtained from Turkish National Permanent GPS Network (TNPGN) is developed by IONOLAB group (www.ionolab.org). In the present study, the developed detection technique is implemented in a causal setup over the available data set in test phase that enables the real time implementation. The performance of the developed earthquake prediction technique is evaluated by using 10 fold cross validation over the data obtained in 2011. Among the 23 earthquakes that have magnitudes higher than 5, the developed technique can detect precursors of 14 earthquakes while producing 8 false alarms. This study is supported by TUBITAK 115E915 and Joint TUBITAK 114E092 and AS CR 14/001 projects.
Comparison of line transects and point counts for monitoring spring migration in forested wetlands
Wilson, R.R.; Twedt, D.J.; Elliott, A.B.
2000-01-01
We compared the efficacy of 400-m line transects and sets of three point counts at detecting avian richness and abundance in bottomland hardwood forests and intensively managed cottonwood (Populus deltoides) plantations within the Mississippi Alluvial Valley. We detected more species and more individuals on line transects than on three point counts during 218 paired surveys conducted between 24 March and 3 June, 1996 and 1997. Line transects also yielded more birds per unit of time, even though point counts yielded higher estimates of relative bird density. In structurally more-complex bottomland hardwood forests, we detected more species and individuals on line transects, but in more-open cottonwood plantations, transects surpassed point counts only at detecting species within 50 m of the observer. Species richness and total abundance of Nearctic-Neotropical migrants and temperate migrants were greater on line transects within bottomland hardwood forests. Within cottonwood plantations, however, only species richness of Nearctic-Neotropical migrants and total abundance of temperate migrants were greater on line transects. Because we compared survey techniques using the same observer, within the same forest stand on a given day, we assumed that the technique yielding greater estimates of avian species richness and total abundance per unit of effort is superior. Thus, for monitoring migration within hardwood forests of the Mississippi Alluvial Valley, we recommend using line transects instead of point counts.
Ptaszyńska, Aneta A; Borsuk, Grzegorz; Woźniakowski, Grzegorz; Gnat, Sebastian; Małek, Wanda
2014-08-01
Nosemosis is a contagious disease of honeybees (Apis mellifera) manifested by increased winter mortality, poor spring build-up and even the total extinction of infected bee colonies. In this paper, loop-mediated isothermal amplifications (LAMP) were used for the first time to identify and differentiate N. apis and N. ceranae, the causative agents of nosemosis. LAMP assays were performed at a constant temperature of 60 °C using two sets of six species-specific primers, recognising eight distinct fragments of 16S rDNA gene and GspSSD polymerase with strand displacement activity. The optimal time for LAMP and its Nosema species sensitivity and specificity were assessed. LAMP only required 30 min for robust identification of the amplicons. Ten-fold serial dilutions of total DNA isolated from bees infected with microsporidia were used to determine the detection limit of N. apis and N. ceranae DNAs by LAMP and standard PCR assays. LAMP appeared to be 10(3) -fold more sensitive than a standard PCR in detecting N. apis and N. ceranae. LAMP methods developed by us are highly Nosema species specific and allow to identify and differentiate N. apis and N. ceranae. © 2014 Federation of European Microbiological Societies. Published by John Wiley & Sons Ltd. All rights reserved.
Feung, Chao-Shieung; Hamilton, Robert H.; Witham, Francis H.; Mumma, Ralph O.
1972-01-01
Soybean (Glycine max L.) cotyledon callus grown on radioactive 2,4-dichlorophenoxyacetic acid (2,4-D-1-14C) as an auxin produced 2,4-D metabolites, which qualitatively and quantitatively changed with time. Water soluble fractions from the tissue exhibited a steady increase in radioactivity during the course of 24 days. Following β-glucosidase treatment, at least eight aglycones were obtained from the water soluble fraction of the tissue after 8 days. The metabolite, 4-hydroxy-2,5-dichlorophenoxyacetic acid was the most abundant aglycone during the entire 32 day growth period while 4-hydroxy-2,3-dichlorophenoxyacetic acid was detected as a minor metabolite. Radioactivity in the ether soluble acidic fractions reached a maximum of 82% of the total in the tissue after 2 days. The level then decreased to 44% by the end of 24 days. A total of seven ether soluble components were detected. In addition to 2,4-D glutamic acid, which was detected in high amounts after 24 hours, 2,4-D aspartic acid was found to be the most abundant ether soluble metabolite after longer time periods. Mass spectral data and a fragmentation pattern are presented for 2,4-D aspartic acid. PMID:16658138
Halligan, E; Edgeworth, J; Bisnauthsing, K; Bible, J; Cliff, P; Aarons, E; Klein, J; Patel, A; Goldenberg, S
2014-08-01
Laboratory diagnosis and clinical management of inpatients with diarrhoea is complex and time consuming. Tests are often requested sequentially and undertaken in different laboratories. This causes prolonged unnecessary presumptive isolation of patients, because most cases are non-infectious. A molecular multiplex test (Luminex(®) Gastrointestinal Pathogen Panel (GPP)) was compared with conventional testing over 8 months to determine diagnostic accuracy, turnaround times, laboratory costs, use of isolation facilities and user acceptability. A total of 262 (12%) patients had a pathogen detected by conventional methods compared with 483 (22.1%) by GPP. Most additional cases were detected in patients developing symptoms in the first 4 days of admission. Additional cases were detected because of presumed improved diagnostic sensitivity but also because clinicians had not requested the correct pathogen. Turnaround time (41.8 h) was faster than bacterial culture (66.5 h) and parasite investigation (66.5 h) but slower than conventional testing for Clostridium difficile (17.3 h) and viruses (27 h). The test could allow simplified requesting by clinicians and a consolidated laboratory workflow, reducing the overall number of specimens received by the laboratory. A total of 154 isolation days were saved at an estimated cost of £30 800. Consumables and labour were estimated at £150 641 compared with £63 431 for conventional testing. Multiplex molecular testing using a panel of targets allowed enhanced detection and a consolidated laboratory workflow. This is likely to be of greater benefit to cases that present within the first 4 days of hospital admission. © 2013 The Authors Clinical Microbiology and Infection © 2013 European Society of Clinical Microbiology and Infectious Diseases.
NASA Astrophysics Data System (ADS)
Lutsch, E.; Conway, S. A.; Strong, K.; Jones, D. B. A.; Drummond, J. R.; Ortega, I.; Hannigan, J. W.; Makarova, M.; Notholt, J.; Blumenstock, T.; Sussmann, R.; Mahieu, E.; Kasai, Y.; Clerbaux, C.
2017-12-01
We present a multi-year time series of the total columns of carbon monoxide (CO), hydrogen cyanide (HCN) and ethane (C2H6) obtained by Fourier Transform Infrared (FTIR) spectrometer measurements at nine sites. Six are high-latitude sites: Eureka, Nunavut; Ny Alesund, Norway; Thule, Greenland; Kiruna, Sweden; Poker Flat, Alaska and St. Petersburg, Russia and three are mid-latitude sites; Zugspitze, Germany; Jungfraujoch, Switzerland and Toronto, Ontario. For each site, the inter-annual trends and seasonal variabilities of the CO total column time series are accounted for, allowing ambient concentrations to be determined. Enhancements above ambient levels are then used to identify possible wildfire pollution events. Since the abundance of each trace gas species emitted in a wildfire event is specific to the type of vegetation burned and the burning phase, correlations of CO to the other long-lived wildfire tracers HCN and C2H6 allow for further confirmation of the detection of wildfire pollution. Back-trajectories from HYSPLIT and FLEXPART as well as fire detections from the Moderate Resolution Spectroradiometer (MODIS) allow the source regions of the detected enhancements to be determined while satellite observations of CO from the Measurement of Pollution in the Troposphere (MOPITT) and Infrared Atmospheric Sounding Interferometer (IASI) instruments can be used to track the transport of the smoke plume. Differences in travel times between sites allows ageing of biomass burning plumes to be determined, providing a means to infer the physical and chemical processes affecting the loss of each species during transport. Comparisons of ground-based FTIR measurements to GEOS-Chem chemical transport model results are used to investigate these processes, evaluate wildfire emission inventories and infer the influence of wildfire emissions on the Arctic.
Bird Radar Validation in the Field by Time-Referencing Line-Transect Surveys
Dokter, Adriaan M.; Baptist, Martin J.; Ens, Bruno J.; Krijgsveld, Karen L.; van Loon, E. Emiel
2013-01-01
Track-while-scan bird radars are widely used in ornithological studies, but often the precise detection capabilities of these systems are unknown. Quantification of radar performance is essential to avoid observational biases, which requires practical methods for validating a radar’s detection capability in specific field settings. In this study a method to quantify the detection capability of a bird radar is presented, as well a demonstration of this method in a case study. By time-referencing line-transect surveys, visually identified birds were automatically linked to individual tracks using their transect crossing time. Detection probabilities were determined as the fraction of the total set of visual observations that could be linked to radar tracks. To avoid ambiguities in assigning radar tracks to visual observations, the observer’s accuracy in determining a bird’s transect crossing time was taken into account. The accuracy was determined by examining the effect of a time lag applied to the visual observations on the number of matches found with radar tracks. Effects of flight altitude, distance, surface substrate and species size on the detection probability by the radar were quantified in a marine intertidal study area. Detection probability varied strongly with all these factors, as well as species-specific flight behaviour. The effective detection range for single birds flying at low altitude for an X-band marine radar based system was estimated at ∼1.5 km. Within this range the fraction of individual flying birds that were detected by the radar was 0.50±0.06 with a detection bias towards higher flight altitudes, larger birds and high tide situations. Besides radar validation, which we consider essential when quantification of bird numbers is important, our method of linking radar tracks to ground-truthed field observations can facilitate species-specific studies using surveillance radars. The methodology may prove equally useful for optimising tracking algorithms. PMID:24066103
Bird radar validation in the field by time-referencing line-transect surveys.
Dokter, Adriaan M; Baptist, Martin J; Ens, Bruno J; Krijgsveld, Karen L; van Loon, E Emiel
2013-01-01
Track-while-scan bird radars are widely used in ornithological studies, but often the precise detection capabilities of these systems are unknown. Quantification of radar performance is essential to avoid observational biases, which requires practical methods for validating a radar's detection capability in specific field settings. In this study a method to quantify the detection capability of a bird radar is presented, as well a demonstration of this method in a case study. By time-referencing line-transect surveys, visually identified birds were automatically linked to individual tracks using their transect crossing time. Detection probabilities were determined as the fraction of the total set of visual observations that could be linked to radar tracks. To avoid ambiguities in assigning radar tracks to visual observations, the observer's accuracy in determining a bird's transect crossing time was taken into account. The accuracy was determined by examining the effect of a time lag applied to the visual observations on the number of matches found with radar tracks. Effects of flight altitude, distance, surface substrate and species size on the detection probability by the radar were quantified in a marine intertidal study area. Detection probability varied strongly with all these factors, as well as species-specific flight behaviour. The effective detection range for single birds flying at low altitude for an X-band marine radar based system was estimated at ~1.5 km. Within this range the fraction of individual flying birds that were detected by the radar was 0.50 ± 0.06 with a detection bias towards higher flight altitudes, larger birds and high tide situations. Besides radar validation, which we consider essential when quantification of bird numbers is important, our method of linking radar tracks to ground-truthed field observations can facilitate species-specific studies using surveillance radars. The methodology may prove equally useful for optimising tracking algorithms.
NASA Astrophysics Data System (ADS)
Huang, Alex S.; Belghith, Akram; Dastiridou, Anna; Chopra, Vikas; Zangwill, Linda M.; Weinreb, Robert N.
2017-06-01
The purpose was to create a three-dimensional (3-D) model of circumferential aqueous humor outflow (AHO) in a living human eye with an automated detection algorithm for Schlemm's canal (SC) and first-order collector channels (CC) applied to spectral-domain optical coherence tomography (SD-OCT). Anterior segment SD-OCT scans from a subject were acquired circumferentially around the limbus. A Bayesian Ridge method was used to approximate the location of the SC on infrared confocal laser scanning ophthalmoscopic images with a cross multiplication tool developed to initiate SC/CC detection automated through a fuzzy hidden Markov Chain approach. Automatic segmentation of SC and initial CC's was manually confirmed by two masked graders. Outflow pathways detected by the segmentation algorithm were reconstructed into a 3-D representation of AHO. Overall, only <1% of images (5114 total B-scans) were ungradable. Automatic segmentation algorithm performed well with SC detection 98.3% of the time and <0.1% false positive detection compared to expert grader consensus. CC was detected 84.2% of the time with 1.4% false positive detection. 3-D representation of AHO pathways demonstrated variably thicker and thinner SC with some clear CC roots. Circumferential (360 deg), automated, and validated AHO detection of angle structures in the living human eye with reconstruction was possible.
Zhu, Yinglian; Wang, Dongfeng
2016-12-01
Chitosan immunomagnetic beads (CIBs) were first prepared through converting hydroxyl groups of natural polymer material-chitosan into amino groups using epichlorohydrin and ethylenediamine as modification agent and then coupling with polyclonal antibodies of Enterobacter sakazakii using glutaraldehyde as cross-linking agent. The beads before coupling with antibodies were characterized by magnetic property measurement, FTIR, SEM and XRD technologies. In the assay a natural polysaccharide-chitosan, which has good biological and chemical properties such as non-toxicity, biocompatibility and high chemical reactivity was first used for synthesis of immunomagnetic beads. The detection method first established in this paper that combined the beads with chromogenic medium together to rapid detect E. sakazakii in milk powder could greatly improve the detection specificity and working efficiency. The beads exhibited a maximum capturing capacity of 1×10 6 cfu/g with the detection sensitivity of 4cfu/g. The results demonstrate that the assay is a straightforward, specific and sensitive alternative for rapid detection of E.sakazakii in food matrix. The total analysis time was as little as about 25h, which greatly shorten the detection time. The method can provides new ideas not only to preparation technique of immunomagnetic beads but to imunne detection technique in food safety. Copyright © 2016 Elsevier B.V. All rights reserved.
Quick detection of QRS complexes and R-waves using a wavelet transform and K-means clustering.
Xia, Yong; Han, Junze; Wang, Kuanquan
2015-01-01
Based on the idea of telemedicine, 24-hour uninterrupted monitoring on electrocardiograms (ECG) has started to be implemented. To create an intelligent ECG monitoring system, an efficient and quick detection algorithm for the characteristic waveforms is needed. This paper aims to give a quick and effective method for detecting QRS-complexes and R-waves in ECGs. The real ECG signal from the MIT-BIH Arrhythmia Database is used for the performance evaluation. The method proposed combined a wavelet transform and the K-means clustering algorithm. A wavelet transform is adopted in the data analysis and preprocessing. Then, based on the slope information of the filtered data, a segmented K-means clustering method is adopted to detect the QRS region. Detection of the R-peak is based on comparing the local amplitudes in each QRS region, which is different from other approaches, and the time cost of R-wave detection is reduced. Of the tested 8 records (total 18201 beats) from the MIT-BIH Arrhythmia Database, an average R-peak detection sensitivity of 99.72 and a positive predictive value of 99.80% are gained; the average time consumed detecting a 30-min original signal is 5.78s, which is competitive with other methods.
Opto-electronic pulsed THz systems
NASA Astrophysics Data System (ADS)
Planken, P. C. M.; van Rijmenam, C. E. W. M.; Schouten, R. N.
2005-07-01
We present an overview of pulsed THz emission and detection schemes and give results of a highly efficient, water-cooled, semi-large aperture THz emitter. Using electro-optic detection we obtain a dynamic range of more than 5000 in a total measurement time of 20 ms, which represents the highest dynamic range for THz emitters centred around femtosecond laser oscillators to date. We find that the detection sensitivity is completely determined by the photon shot-noise of the probe laser beam. As an application of our efficient THz emitter, we present the first measurement of a phonon resonance in a THz apertureless scanning near-field optical microscopy measurement.
Noninvasive photoacoustic detecting intraocular foreign bodies with an annular transducer array.
Yang, Diwu; Zeng, Lvming; Pan, Changning; Zhao, Xuehui; Ji, Xuanrong
2013-01-14
We present a fast photoacoustic imaging system based on an annular transducer array for detection of intraocular foreign bodies. An eight-channel data acquisition system is applied to capture the photoacoustic signals using multiplexing and the total time of data acquisition and transferring is within 3 s. A limited-view filtered back projection algorithm is used to reconstruct the photoacoustic images. Experimental models of intraocular metal and glass foreign bodies were constructed on ex vivo pig's eyes and clear photoacoustic images of intraocular foreign bodies were obtained. Experimental results demonstrate the photoacoustic imaging system holds the potential for in clinic detecting the intraocular foreign bodies.
Direct detection of a BRAF mutation in total RNA from melanoma cells using cantilever arrays
NASA Astrophysics Data System (ADS)
Huber, F.; Lang, H. P.; Backmann, N.; Rimoldi, D.; Gerber, Ch.
2013-02-01
Malignant melanoma, the deadliest form of skin cancer, is characterized by a predominant mutation in the BRAF gene. Drugs that target tumours carrying this mutation have recently entered the clinic. Accordingly, patients are routinely screened for mutations in this gene to determine whether they can benefit from this type of treatment. The current gold standard for mutation screening uses real-time polymerase chain reaction and sequencing methods. Here we show that an assay based on microcantilever arrays can detect the mutation nanomechanically without amplification in total RNA samples isolated from melanoma cells. The assay is based on a BRAF-specific oligonucleotide probe. We detected mutant BRAF at a concentration of 500 pM in a 50-fold excess of the wild-type sequence. The method was able to distinguish melanoma cells carrying the mutation from wild-type cells using as little as 20 ng µl-1 of RNA material, without prior PCR amplification and use of labels.
Berger, Jason; Upton, Colin; Springer, Elyah
2018-04-23
Visualization of nitrite residues is essential in gunshot distance determination. Current protocols for the detection of nitrites include, among other tests, the Modified Griess Test (MGT). This method is limited as nitrite residues are unstable in the environment and limited to partially burned gunpowder. Previous research demonstrated the ability of alkaline hydrolysis to convert nitrates to nitrites, allowing visualization of unburned gunpowder particles using the MGT. This is referred to as Total Nitrite Pattern Visualization (TNV). TNV techniques were modified and a study conducted to streamline the procedure outlined in the literature to maximize the efficacy of the TNV in casework, while reducing the required time from 1 h to 5 min, and enhancing effectiveness on blood-soiled samples. The TNV method was found to provide significant improvement in the ability to detect significant nitrite residues, without sacrificing efficiency, that would allow for the determination of the muzzle-to-target distance. © 2018 American Academy of Forensic Sciences.
Velasco, Valeria; Sherwood, Julie S.; Rojas-García, Pedro P.; Logue, Catherine M.
2014-01-01
The aim of this study was to compare a real-time PCR assay, with a conventional culture/PCR method, to detect S. aureus, mecA and Panton-Valentine Leukocidin (PVL) genes in animals and retail meat, using a two-step selective enrichment protocol. A total of 234 samples were examined (77 animal nasal swabs, 112 retail raw meat, and 45 deli meat). The multiplex real-time PCR targeted the genes: nuc (identification of S. aureus), mecA (associated with methicillin resistance) and PVL (virulence factor), and the primary and secondary enrichment samples were assessed. The conventional culture/PCR method included the two-step selective enrichment, selective plating, biochemical testing, and multiplex PCR for confirmation. The conventional culture/PCR method recovered 95/234 positive S. aureus samples. Application of real-time PCR on samples following primary and secondary enrichment detected S. aureus in 111/234 and 120/234 samples respectively. For detection of S. aureus, the kappa statistic was 0.68–0.88 (from substantial to almost perfect agreement) and 0.29–0.77 (from fair to substantial agreement) for primary and secondary enrichments, using real-time PCR. For detection of mecA gene, the kappa statistic was 0–0.49 (from no agreement beyond that expected by chance to moderate agreement) for primary and secondary enrichment samples. Two pork samples were mecA gene positive by all methods. The real-time PCR assay detected the mecA gene in samples that were negative for S. aureus, but positive for Staphylococcus spp. The PVL gene was not detected in any sample by the conventional culture/PCR method or the real-time PCR assay. Among S. aureus isolated by conventional culture/PCR method, the sequence type ST398, and multi-drug resistant strains were found in animals and raw meat samples. The real-time PCR assay may be recommended as a rapid method for detection of S. aureus and the mecA gene, with further confirmation of methicillin-resistant S. aureus (MRSA) using the standard culture method. PMID:24849624
Velasco, Valeria; Sherwood, Julie S; Rojas-García, Pedro P; Logue, Catherine M
2014-01-01
The aim of this study was to compare a real-time PCR assay, with a conventional culture/PCR method, to detect S. aureus, mecA and Panton-Valentine Leukocidin (PVL) genes in animals and retail meat, using a two-step selective enrichment protocol. A total of 234 samples were examined (77 animal nasal swabs, 112 retail raw meat, and 45 deli meat). The multiplex real-time PCR targeted the genes: nuc (identification of S. aureus), mecA (associated with methicillin resistance) and PVL (virulence factor), and the primary and secondary enrichment samples were assessed. The conventional culture/PCR method included the two-step selective enrichment, selective plating, biochemical testing, and multiplex PCR for confirmation. The conventional culture/PCR method recovered 95/234 positive S. aureus samples. Application of real-time PCR on samples following primary and secondary enrichment detected S. aureus in 111/234 and 120/234 samples respectively. For detection of S. aureus, the kappa statistic was 0.68-0.88 (from substantial to almost perfect agreement) and 0.29-0.77 (from fair to substantial agreement) for primary and secondary enrichments, using real-time PCR. For detection of mecA gene, the kappa statistic was 0-0.49 (from no agreement beyond that expected by chance to moderate agreement) for primary and secondary enrichment samples. Two pork samples were mecA gene positive by all methods. The real-time PCR assay detected the mecA gene in samples that were negative for S. aureus, but positive for Staphylococcus spp. The PVL gene was not detected in any sample by the conventional culture/PCR method or the real-time PCR assay. Among S. aureus isolated by conventional culture/PCR method, the sequence type ST398, and multi-drug resistant strains were found in animals and raw meat samples. The real-time PCR assay may be recommended as a rapid method for detection of S. aureus and the mecA gene, with further confirmation of methicillin-resistant S. aureus (MRSA) using the standard culture method.
Lykins, Amy D; Meana, Marta; Kambe, Gretchen
2006-10-01
As a first step in the investigation of the role of visual attention in the processing of erotic stimuli, eye-tracking methodology was employed to measure eye movements during erotic scene presentation. Because eye-tracking is a novel methodology in sexuality research, we attempted to determine whether the eye-tracker could detect differences (should they exist) in visual attention to erotic and non-erotic scenes. A total of 20 men and 20 women were presented with a series of erotic and non-erotic images and tracked their eye movements during image presentation. Comparisons between erotic and non-erotic image groups showed significant differences on two of three dependent measures of visual attention (number of fixations and total time) in both men and women. As hypothesized, there was a significant Stimulus x Scene Region interaction, indicating that participants visually attended to the body more in the erotic stimuli than in the non-erotic stimuli, as evidenced by a greater number of fixations and longer total time devoted to that region. These findings provide support for the application of eye-tracking methodology as a measure of visual attentional capture in sexuality research. Future applications of this methodology to expand our knowledge of the role of cognition in sexuality are suggested.
A Study of Cen X-3 as Seen by INTEGRAL
NASA Astrophysics Data System (ADS)
La Barbera, A.; Baushev, A.; Ferrigno, C.; Piraino, S.; Santangelo, A.; Segreto, A.; Orlandini, M.; Kretschmar, P.; Kreykenbohm, I.; Wilms, J.; Staubert, R.; Coburn, W.; Heindl, W. A.
2004-10-01
We present a preliminary analysis of 14 observa- tions (Science Windows SCW) of the eclipsing High Mass X ray Binary Pulsar Cen X 3 taken during the Galactic Plane Scan (GPS) with INTEGRAL. The source was detected in 4 SCWs by JEM-X for a total exposure time of 8.7 ksec and in 11 SCWs by ISGRI for a total exposure time of 23.8 ksec. The study of the pulse profile is reported. The 10 70 keV spec- trum is also described. The results are compared with those from previous X ray missions. Key words: pulsars, individual: Cen X 3; stars: neu- tron stars; X rays: binaries.
Gas Chromatographic Presumptive Test for Coliform Bacteria in Water
Newman, Judith S.; O'Brien, R. T.
1975-01-01
A gas chromatographic procedure which shows promise as a presumptive test for coliform bacteria in water is described. Total coliform bacteria concentrations were determined from the incubation times at 37 C required for ethanol to be produced. Fecal coliform densities were determined in a similar manner at 44.5 C. The culture medium was filter sterilized M-9 salts supplemented with 1% lactose, 0.1% Casamino Acids, and 0.1% yeast extract. Best results were obtained when the initial total coliform concentrations were 5 per ml or higher and when fecal coliform concentrations were 50 per ml or higher. Minimum detection times at these concentrations were 9 and 12 h, respectively. PMID:1103731
von Renteln, Daniel; Schmidt, Arthur; Riecken, Bettina; Caca, Karel
2010-05-01
Endoscopic full-thickness plication allows transmural suturing at the gastroesophageal junction to recreate the antireflux barrier. Multichannel intraluminal impedance monitoring (MII) can be used to detect nonacid or weakly acidic reflux, acidic swallows, and esophageal clearance time. This study used MII to evaluate the outcome of endoscopic full-thickness plication. In this study, 12 subsequent patients requiring maintenance proton pump inhibitor therapy underwent endoscopic full-thickness plication for treatment of gastroesophageal reflux disease. With patients off medication, MII was performed before and 6-months after endoscopic full-thickness plication. The total median number of reflux episodes was significantly reduced from 105 to 64 (p = 0.016). The median number of acid reflux episodes decreased from 73 to 43 (p = 0.016). Nonacid reflux episodes decreased from 23 to 21 (p = 0.306). The median bolus clearance time was 12 s before treatment and 11 s at 6 months (p = 0.798). The median acid exposure time was reduced from 6.8% to 3.4% (p = 0.008), and the DeMeester scores were reduced from 19 to 12 (p = 0.008). Endoscopic full-thickness plication significantly reduced total reflux episodes, acid reflux episodes, and total reflux exposure time. The DeMeester scores and total acid exposure time for the distal esophagus were significantly improved. No significant changes in nonacid reflux episodes and median bolus clearance time were encountered.
NASA Astrophysics Data System (ADS)
Wollenweber, S. D.; Tsui, B. M. W.; Lalush, D. S.; Frey, E. C.; Gullberg, G. T.
1998-08-01
The objective of this study was to implement the Hotelling trace (HT) to evaluate the potential increase in defect detection in myocardial SPECT using high-resolution fan-beam (HRF) versus parallel-hole (HRP) collimation and compare results to a previously reported human observer study (G.K. Gregoriou et al., ibid., vol. 42, p. 1267-75, 1995). Projection data from the 3D MCAT torso phantom were simulated including the effects of attenuation, collimator-detector response blurring and scatter. Poisson noise fluctuations were then simulated. The HRP and HRF collimators had the same spatial resolution at 20 cm. The total counts in the projection data sets were proportional to the detection efficiencies of the collimators and on the order of that found in clinical Tc-99m studies. In six left-ventricular defect locations, the HT found for HRF was superior to that for HRP collimation. For HRF collimation, the HT was calculated for reconstructed images using 64/spl times/64, 128/spl times/128 and 192/spl times/192 grid sizes. The results demonstrate substantial improvement in myocardial defect detection when the grid size was increased from 64/spl times/64 to 128/spl times/128 and slight improvement from 128/spl times/128 to 192/spl times/192. Also, the performance of the Hotelling observer in terms of the HT at the different grid sizes correlates at better than 0.95 to that found in human observers in a previously reported observer experiment and ROC study.
Melendez, Johan H; Santaus, Tonya M; Brinsley, Gregory; Kiang, Daniel; Mali, Buddha; Hardick, Justin; Gaydos, Charlotte A; Geddes, Chris D
2016-10-01
Nucleic acid-based detection of gonorrhea infections typically require a two-step process involving isolation of the nucleic acid, followed by detection of the genomic target often involving polymerase chain reaction (PCR)-based approaches. In an effort to improve on current detection approaches, we have developed a unique two-step microwave-accelerated approach for rapid extraction and detection of Neisseria gonorrhoeae (gonorrhea, GC) DNA. Our approach is based on the use of highly focused microwave radiation to rapidly lyse bacterial cells, release, and subsequently fragment microbial DNA. The DNA target is then detected by a process known as microwave-accelerated metal-enhanced fluorescence (MAMEF), an ultra-sensitive direct DNA detection analytical technique. In the current study, we show that highly focused microwaves at 2.45 GHz, using 12.3-mm gold film equilateral triangles, are able to rapidly lyse both bacteria cells and fragment DNA in a time- and microwave power-dependent manner. Detection of the extracted DNA can be performed by MAMEF, without the need for DNA amplification, in less than 10 min total time or by other PCR-based approaches. Collectively, the use of a microwave-accelerated method for the release and detection of DNA represents a significant step forward toward the development of a point-of-care (POC) platform for detection of gonorrhea infections. Copyright © 2016 Elsevier Inc. All rights reserved.
Jia, Bei-Xi; Huangfu, Qian-Qian; Ren, Feng-Xiao; Jia, Lu; Zhang, Yan-Bing; Liu, Hong-Min; Yang, Jie; Wang, Qiang
2015-01-01
This article marks the first report on high-performance liquid chromatography (HPLC) coupled with diode-array detection (DAD) and quadruple time-of-flight mass spectrometry (Q-TOF/MS) for the identification and quantification of main bioactive constituents in Baeckea frutescens. In total, 24 compounds were identified or tentatively characterised based on their retention behaviours, UV profiles and MS fragment information. Furthermore, a validated method with good linearity, sensitivity, precision, stability, repeatability and accuracy was successfully applied for simultaneous determination of five flavonoids and one chromone in different plant parts of B. frutescens collected at different harvest times, and their dynamic contents revealed the appropriate harvest times. The established HPLC-DAD-Q-TOF/MS using multi-bioactive markers was proved to be a validated strategy for the quality evaluation on both raw materials and related products of B. frutescens.
Cacciola, Francesco; Beccaria, Marco; Oteri, Marianna; Utczas, Margita; Giuffrida, Daniele; Cicero, Nicola; Dugo, Giacomo; Dugo, Paola; Mondello, Luigi
2016-07-01
We report an extensive chemical characterisation of fatty acids, triacylglycerols, tocopherols, carotenoids and polyphenols contained in the oil extracted from old cabbage (Brassica oleracea L. var. acephala) by cold-pressing of the seeds. Analyses were performed by GC-FID combined with mass spectrometry, HPLC with photodiode array, fluorescence and mass spectrometry detection. The 94% of the total fatty acids were unsaturated, rappresented by erucic acid (more than 50%) followed by linoleic, linolenic and oleic acids accounting for approximately 10% each. The most abundant triacylglycerols (>13%) were represented by erucic-gadolenic-linoleic, erucic-eruci-linoleic and erucic-erucic-oleic. Among tocopherols, γ-tocopherol accounted for over 70% of the total content. Thirteen carotenoids and 11 polyphenols were identified and measured. In particular, the total content in carotenoids was 10.9 ppm and all-E-lutein was the main component (7.7 ppm); among polyphenols, six hydroxycinnamic acids and five flavonoids, were identified by combining information from retention times, PDA and MS data.
Monitoring cow activity and rumination time for an early detection of heat stress in dairy cow.
Abeni, Fabio; Galli, Andrea
2017-03-01
The aim of this study was to explore the use of cow activity and rumination time by precision livestock farming tools as early alert for heat stress (HS) detection. A total of 58 Italian Friesian cows were involved in this study during summer 2015. Based on the temperature humidity index (THI), two different conditions were compared on 16 primiparous and 11 multiparous, to be representative of three lactation phases: early (15-84 DIM), around peak (85-154 DIM), and plateau (155-224 DIM). A separate dataset for the assessment of the variance partition included all the cows in the herd from June 7 to July 16. The rumination time (RT2h, min/2 h) and activity index (AI2h, bouts/2 h) were summarized every 2-h interval. The raw data were used to calculate the following variables: total daily RT (RTt), daytime RT (RTd), nighttime RT (RTn), total daily AI (AIt), daytime AI (AId), and nighttime AI (AIn). Either AIt and AId increased, whereas RTt, RTd, and RTn decreased with higher THI in all the three phases. The highest decrease was recorded for RTd and ranged from 49 % (early) to 45 % (plateau). The contribution of the cow within lactation phase was above 60 % of the total variance for AI traits and a share from 33.9 % (for RTt) to 54.8 % (RTn) for RT traits. These observations must be extended to different feeding managements and different animal genetics to assess if different thresholds could be identified to set an early alert system for the farmer.
NASA Technical Reports Server (NTRS)
Christian, Hugh J.
2004-01-01
Our knowledge of the global distribution of lightning has improved dramatically since the advent of spacebased lightning observations. Of major importance was the 1995 launch of the Optical Transient Detector (OTD), followed in 1997 by the launch of the Lightning Imaging Sensor (LIS). Together, these instruments have generated a continuous eight-year record of global lightning activity. These lightning observations have provided a new global perspective on total lightning activity. For the first time, total lightning activity (cloud-to-ground and intra-cloud) has been observed over large regions with high detection efficiency and accurate geographic location. This has produced new insights into lightning distributions, times of occurrence and variability. It has produced a revised global flash rate estimate (44 flashes per second) and has lead to a new realization of the significance of total lightning activity in severe weather. Accurate flash rate estimates are now available over large areas of the earth (+/- 72 deg. latitude). Ocean-land contrasts as a function of season are clearly reveled, as are orographic effects and seasonal and interannual variability. The space-based observations indicate that air mass thunderstorms, not large storm system dominate global activity. The ability of LIS and OTD to detect total lightning has lead to improved insight into the correlation between lightning and storm development. The relationship between updraft development and lightning activity is now well established and presents an opportunity for providing a new mechanism for remotely monitoring storm development. In this concept, lightning would serve as a surrogate for updraft velocity. It is anticipated that this capability could lead to significantly improved severe weather warning times and reduced false warning rates. This talk will summarize our space-based lightning measurements, will discuss how lightning observations can be used to monitor severe weather, and present a concept for continuous geostationary-based lightning observations.
NASA Astrophysics Data System (ADS)
Mazur, J. E.; Guild, T. B.; Crain, W.; Crain, S.; Holker, D.; Quintana, S.; O'Brien, T. P., III; Kelly, M. A.; Barnes, R. J.; Sotirelis, T.
2017-12-01
The Responsive Environmental Assessment Commercial Hosting (REACH) project uses radiation dosimeters on a commercial satellite constellation in low Earth orbit to provide unprecedented spatial and time sampling of space weather radiation hazards. The spatial and time scales of natural space radiation environments coupled with constraints for the hosting accommodation drove the instrumentation requirements and the plan for the final orbital constellation. The project has delivered a total of thirty two radiation dosimeter instruments for launch with each instrument containing two dosimeters with different passive shielding and electronic thresholds to address proton-induced single-event effects, vehicle charging, and total ionizing dose. There are two REACH instruments currently operating with four more planned for launch by the time of the 2017 meeting. Our aim is to field a long-lived system of highly-capable radiation detectors to monitor the hazards of single-event effects, total ionizing dose, and spacecraft charging with maximized spatial coverage and with minimal time latency. We combined a robust detection technology with a commercial satellite hosting to produce a new demonstration for satellite situational awareness and for other engineering and science applications.
Fu, Yung-Chieh; Liao, I-Chuang; Chen, Hung-Mo; Yan, Jing-Jou
2016-07-01
The Abbott RealTime MTB assay, launched in June 2014, has been shown to have a competitive performance in the detection of the Mycobacterium tuberculosis (MTB) complex in respiratory specimens. The present study was conducted to investigate the usefulness of the Abbott MTB Realtime assay in the detection of MTB in formalin-fixed paraffin-embedded (FFPE) tissues. A total of 96 FFPE specimens obtained from microbiologically proven MTB cases (N=60) and nontuberculous Mycobacterium cases (N=36) were analyzed. The performance of the Abbott MTB Realtime assay was compared with that of the Roche Cobas TaqMan MTB assay. The overall sensitivity and specificity of the Abbott assay were 63.3% and 97.2%, respectively, compared with 11.7% and 100% for the Cobas assay. The detection rate of the Abbott assay was much higher among 37 acid-fast-positive specimens than among 23 acid-fast-negative specimens (89.3% versus 21.7%, respectively). The detection rate of the assay was higher among 29 resection specimens than among 31 small biopsy specimens (86.2% versus 41.9%, respectively). Our results suggest that the Abbott RealTime MTB assay can be used to differentiate MTB from nontuberculous mycobacterial infections in acid-fast-positive FFPE tissues. © 2016 by the Association of Clinical Scientists, Inc.
Development of real-time RT-PCR for the detection of low concentrations of Rift Valley fever virus.
Maquart, Marianne; Temmam, Sarah; Héraud, Jean-Michel; Leparc-Goffart, Isabelle; Cêtre-Sossah, Catherine; Dellagi, Koussay; Cardinale, Eric; Pascalis, Hervé
2014-01-01
In recent years, Madagascar and the Comoros archipelago have been affected by epidemics of Rift Valley fever (RVF), however detection of Rift Valley fever virus (RVFV) in zebu, sheep and goats during the post epidemic periods was frequently unsuccessful. Thus, a highly sensitive real-time RT-PCR assay was developed for the detection of RVFV at low viral loads. A new RVF SYBR Green RT-PCR targeting the M segment was tested on serum from different RVF seronegative ruminant species collected from May 2010 to August 2011 in Madagascar and the Comoros archipelago and compared with a RVF specific quantitative real time RT-PCR technique, which is considered as the reference technique. The specificity was tested on a wide range of arboviruses or other viruses giving RVF similar clinical signs. A total of 38 out of 2756 serum samples tested positive with the new RT-PCR, whereas the reference technique only detected 5 out of the 2756. The described RT-PCR is an efficient diagnostic tool for the investigation of enzootic circulation of the RVF virus. It allows the detection of low viral RNA loads adapted for the investigations of reservoirs or specific epidemiological situations such as inter-epizootic periods. Copyright © 2013 Elsevier B.V. All rights reserved.
Detection of exogenous gene doping of IGF-I by a real-time quantitative PCR assay.
Zhang, Jin-Ju; Xu, Jing-Feng; Shen, Yong-Wei; Ma, Shi-Jiao; Zhang, Ting-Ting; Meng, Qing-Lin; Lan, Wen-Jun; Zhang, Chun; Liu, Xiao-Mei
2017-07-01
Gene doping can be easily concealed since its product is similar to endogenous protein, making its effective detection very challenging. In this study, we selected insulin-like growth factor I (IGF-I) exogenous gene for gene doping detection. First, the synthetic IGF-I gene was subcloned to recombinant adeno-associated virus (rAAV) plasmid to produce recombinant rAAV2/IGF-I-GFP vectors. Second, in an animal model, rAAV2/IGF-I-GFP vectors were injected into the thigh muscle tissue of mice, and then muscle and blood specimens were sampled at different time points for total DNA isolation. Finally, real-time quantitative PCR was employed to detect the exogenous gene doping of IGF-I. In view of the characteristics of endogenous IGF-I gene sequences, a TaqMan probe was designed at the junction of exons 2 and 3 of IGF-I gene to distinguish it from the exogenous IGF-I gene. In addition, an internal reference control plasmid and its probe were used in PCR to rule out false-positive results through comparison of their threshold cycle (Ct) values. Thus, an accurate exogenous IGF-I gene detection approach was developed in this study. © 2016 International Union of Biochemistry and Molecular Biology, Inc.
Liang, L; Jin, Y X; Zhu, X Q; Zhou, F L; Yang, Y
2018-05-15
Real-time detection and monitoring of the drug resistance of single cells have important significance in clinical diagnosis and therapy. Traditional methods operate a number of times for each individual concentration, and innovation is required for the design of more simple and efficient manipulation platforms with necessary higher sensitivity. Here, we have developed a novel diffused total internal reflection (TIR) method to perform drug metabolism and cytotoxicity analysis of trapped myeloid leukemia cells. Molm-13 cells, a type of acute myeloid leukemia cell, were chosen and injected into the device and fittingly captured by cell traps. Differing from previous studies, a series of different concentrations of azelaic acid (AZA) drug could be used from 0 mM to 50 mM through convection and diffusion processes in a single chip, with each concentration region featuring 50 cells, with a total of 549 cell trapping units. Thanks to the high sensitivity of the TIR method, only cells with the same drug concentration could be illuminated in the detection process. By adjusting the incident angle, we could exactly detect and monitor the drug resistance of the cells using different drug concentrations and the experimental resolution of the drug concentration was as small as 5 mM. Images of the membrane integrity and morphology of the cells in the bright field were measured and we also monitored the cell viabilities in the dark field over 2 hours. The effects of AZA on the Molm-13 cells were explored in different concentrations at the single cell level. Compared with the results of the traditional MTT assay method, the experimental results are more simple and accurate. A cell death of 5% at an AZA concentration of 5 mM was observed after 30 minutes, while a concentration of 40 mM corresponded to a 98% cell death. The designed method in this study provides a novel toolkit to control and monitor drug resistance at the single cell level more easily with higher sensitivity and we believe it has significant potential application in single cell quality assessment and medicine analysis in clinical practice.
A web-based quantitative signal detection system on adverse drug reaction in China.
Li, Chanjuan; Xia, Jielai; Deng, Jianxiong; Chen, Wenge; Wang, Suzhen; Jiang, Jing; Chen, Guanquan
2009-07-01
To establish a web-based quantitative signal detection system for adverse drug reactions (ADRs) based on spontaneous reporting to the Guangdong province drug-monitoring database in China. Using Microsoft Visual Basic and Active Server Pages programming languages and SQL Server 2000, a web-based system with three software modules was programmed to perform data preparation and association detection, and to generate reports. Information component (IC), the internationally recognized measure of disproportionality for quantitative signal detection, was integrated into the system, and its capacity for signal detection was tested with ADR reports collected from 1 January 2002 to 30 June 2007 in Guangdong. A total of 2,496 associations including known signals were mined from the test database. Signals (e.g., cefradine-induced hematuria) were found early by using the IC analysis. In addition, 291 drug-ADR associations were alerted for the first time in the second quarter of 2007. The system can be used for the detection of significant associations from the Guangdong drug-monitoring database and could be an extremely useful adjunct to the expert assessment of very large numbers of spontaneously reported ADRs for the first time in China.
A Total Validation Approach for assessing the RST technique in forest fire detection and monitoring
NASA Astrophysics Data System (ADS)
Mazzeo, Giuseppe; Baldassarre, Giuseppe; Corrado, Rosita; Filizzola, Carolina; Genzano, Nicola; Marchese, Francesco; Paciello, Rossana; Pergola, Nicola; Tramutoli, Valerio
2010-05-01
Several studies have shown that high temporal resolution sensors such as AVHRR (Advanced Very High Resolution Radiometer) aboard NOAA (National Oceanic and Atmospheric Administration) satellites, MODIS (Moderate Resolution Imaging Spectroradiometer) aboard EOS (Earth Observing System) satellites and, more recently, SEVIRI (Spinning Enhanced Visible and Infrared Imager) aboard MSG (Meteosat Second Generation) platforms, are suitable for detecting and monitoring forest fires. At the same time, many satellite-based techniques have been proposed for fire detection, but most of them, based on single image fixed-thresholds, often generate false alarms mainly due to the contribution of the reflected solar radiation in daytime, atmospheric effects, etc., so that they result to have scarce reliability when applied in an operational scenario. Other algorithms, which are quite reliable thanks to their multitemporal and/or contextual nature, may turn out to be hardly applicable so that they cannot be inserted in whatever operative schemes. An innovative approach, named RST - Robust Satellite Technique, already applied for the monitoring of major natural and environmental risks has been recently used for fire detection and monitoring. The RST approach is based on local (in space and time) thresholds which are automatically computed on the basis of long temporal series of satellite data. It demonstrated already good performances in many cases of applications, but recently for the first time a total validation approach (TVA) was experimented in collaboration with administrators, decision makers and local agencies, in order to evaluate the actual reliability and sensitivity of RST in a pre-operational context. TVA, based on a systematic study of the origin of each hot spot identified by RST, allowed us to recognize most of them as actual thermal anomalies (associated to small fires, to variations of thermal emission in industrial plants, etc.) and not as false alarms simply because not associated to officially documented forest fires. Some results of recent campaigns both of winter and summer fire detection and monitoring in Italy will be shown and discussed.
Occurrence of perfluorinated compounds in raw water from New Jersey public drinking water systems.
Post, Gloria B; Louis, Judith B; Lippincott, R Lee; Procopio, Nicholas A
2013-01-01
Perfluorooctanoic acid (PFOA) and perfluorooctane sulfonic acid (PFOS) were previously detected (≥ 4 ng/L) in 65% and 30%, respectively, of 23 New Jersey (NJ) public drinking water systems (PWS) sampled in 2006. We now report on a 2009 study of the occurrence of PFOA, PFOS, and eight other perfluorinated compounds (PFCs) in raw water samples from 30 intakes (18 groundwater and 12 surface water) from 29 additional NJ PWS. Between 1 and 8 PFCs were detected (≥ 5 ng/L) in 21 (70%) of 30 PWS samples at total PFC concentrations of 5-174 ng/L. Although PFOA was the most commonly detected PFC (57% of samples) and was found at the highest maximum concentration (100 ng/L), some of the higher levels of other PFCs were at sites with little or no PFOA. Perfluorononanoic acid was detected more frequently (30%) and at higher concentrations (up to 96 ng/L) than in raw or finished drinking water elsewhere, and it was found at several sites as the sole or predominant PFC, a pattern not reported in other drinking water studies. PFOS, perfluoropentanoic acid, and perfluorohexanoic acid were each detected in more than 20% of samples, while perfluoroheptanoic acid, perfluorobutane sulfonic acid, and perfluorohexane sulfonic acid were detected less frequently. Perfluorobutanoic acid was found only once (6 ng/L), and perfluorodecanoic acid was not detected. Total PFCs were highest in two reservoirs near an airfield; these were also the only sites with total perfluorosulfonic acids higher than total perfluorocarboxylic acids (PFCAs). PFC levels in raw and finished water from the same source were similar at those sites where both were tested. Five wells of two additional NJ PWS known to be contaminated with PFOA were also each sampled 4-9 times in 2010-13 for nine of the same PFCs. Total PFCs (almost completely PFCAs) at one of these PWS located near an industrial source of PFCs were higher than in any other PWS tested (up to 330 ng/L). These results show that multiple PFCs are commonly found in raw water from NJ PWS. Future work is needed to develop approaches for assessing the potential human health risks of exposure to mixtures of PFCs found in drinking water and other environmental media.
Speckle interferometry at SOAR in 2012 and 2013
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tokovinin, Andrei; Mason, Brian D.; Hartkopf, William I., E-mail: atokovinin@ctio.noao.edu, E-mail: bdm@usno.navy.mil, E-mail: wih@usno.navy.mil
2014-05-01
We report the results of speckle runs at the 4.1 m Southern Astronomical Research telescope in 2012 and 2013. A total of 586 objects were observed. We give 699 measurements of 487 resolved binaries and upper detection limits for 112 unresolved stars. Eleven pairs (including one triple) were resolved for the first time. Orbital elements have been determined for the first time for 13 pairs; orbits of another 45 binaries are revised or updated.
Liu, E-Hu; Qi, Lian-Wen; Li, Bin; Peng, Yong-Bo; Li, Ping; Li, Chang-Yin; Cao, Jun
2009-01-01
A fast high-performance liquid chromatography (HPLC) method coupled with diode-array detection (DAD) and electrospray ionization time-of-flight mass spectrometry (ESI-TOFMS) has been developed for rapid separation and sensitive identification of major constituents in Radix Paeoniae Rubra (RPR). The total analysis time on a short column packed with 1.8-microm porous particles was about 20 min without a loss in resolution, six times faster than the performance of a conventional column analysis (115 min). The MS fragmentation behavior and structural characterization of major compounds in RPR were investigated here for the first time. The targets were rapidly screened from RPR matrix using a narrow mass window of 0.01 Da to restructure extracted ion chromatograms. Accurate mass measurements (less than 5 ppm error) for both the deprotonated molecule and characteristic fragment ions represent reliable identification criteria for these compounds in complex matrices with similar if not even better performance compared with tandem mass spectrometry. A total of 26 components were screened and identified in RPR including 11 monoterpene glycosides, 11 galloyl glucoses and 4 other phenolic compounds. From the point of time savings, resolving power, accurate mass measurement capability and full spectral sensitivity, the established fast HPLC/DAD/TOFMS method turns out to be a highly useful technique to identify constituents in complex herbal medicines. (c) 2008 John Wiley & Sons, Ltd.
Liang, Zhanbei; Keeley, Ann
2011-01-01
Extraction of high-quality mRNA from Cryptosporidium parvum is a key step in PCR detection of viable oocysts in environmental samples. Current methods for monitoring oocysts are limited to water samples; therefore, the goal of this study was to develop a rapid and sensitive procedure for Cryptosporidium detection in soil samples. The efficiencies of five RNA extraction methods were compared (mRNA extraction with the Dynabeads mRNA Direct kit after chemical and physical sample treatments, and total RNA extraction methods using the FastRNA Pro Soil-Direct, PowerSoil Total RNA, E.Z.N.A. soil RNA, and Norgen soil RNA purification kits) for the direct detection of Cryptosporidium with oocyst-spiked sandy, loamy, and clay soils by using TaqMan reverse transcription-PCR. The study also evaluated the presence of inhibitors by synthesis and incorporation of an internal positive control (IPC) RNA into reverse transcription amplifications, used different facilitators (bovine serum albumin, yeast RNA, salmon DNA, skim milk powder, casein, polyvinylpyrrolidone, sodium hexametaphosphate, and Salmonella enterica serovar Typhi) to mitigate RNA binding on soil components, and applied various treatments (β-mercaptoethanol and bead beating) to inactivate RNase and ensure the complete lysis of oocysts. The results of spiking studies showed that Salmonella cells most efficiently relieved binding of RNA. With the inclusion of Salmonella during extraction, the most efficient mRNA method was Dynabeads, with a detection limit of 6 × 102 oocysts g−1 of sandy soil. The most efficient total RNA method was PowerSoil, with detection limits of 1.5 × 102, 1.5 × 103, and 1.5 × 104 C. parvum oocysts g−1 soil for sandy, loamy, and clay samples, respectively. PMID:21803904
Use of LANDSAT-1 data for the detection and mapping of saline seeps in Montana
NASA Technical Reports Server (NTRS)
May, G. A. (Principal Investigator); Petersen, G. W.
1976-01-01
The author has identified the following significant results. April, May, and August are the best times to detect saline seeps. Specific times within these months would be dependent upon weather, phenology, and growth conditions. Saline seeps can be efficiently and accurately mapped, within resolution capabilities, from merged May and August LANDSAT 1 data. Seeps were mapped by detecting salt crusts in the spring and indicator plants in the fall. These indicator plants were kochia, inkweed, and foxtail barley. The total hectares of the mapped saline seeps were calculated and tabulated. Saline seeps less than two hectares in size or that have linear configurations less than 200 meters in width were not mapped using the LANDSAT 1 data. Saline seep signatures developed in the Coffee Creek test site were extended to map saline seeps located outside this area.
Evaluation of incubation time for dermatophytes cultures.
Rezusta, Antonio; de la Fuente, Sonia; Gilaberte, Yolanda; Vidal-García, Matxalen; Alcalá, Leticia; López-Calleja, Ana; Ruiz, Maria Angeles; Revillo, Maria José
2016-07-01
In general, it is recommended to incubate dermatophytes cultures for a minimum of 4 weeks. Several aspects of routine fungal cultures should be evaluated in order to implement appropriate and necessary changes. The aim of this study was to determine the optimum incubation time for routine dermatophytes cultures, analysing the time to find first fungal growth by visual observation. We recorded the time when the initial growth was detected for all dermatophyte isolates during a 4-year period. A total of 5459 dermatophyte cultures were submitted to our laboratory. From the total cultures, only 16 (1.42%) isolates were recovered over/after 17 days of incubation and only three dermatophyte species were recovered over 17 days. Fourteen isolates belong to Trichophyton rubrum, one isolate to Trichophyton mentagrophytes complex and one isolate to Epidermophyton floccosum. We concluded that an incubation period of 17 days is enough to establish a microbiological diagnosis of dermatophytosis. © 2016 Blackwell Verlag GmbH.
The GOES-R Geostationary Lightning Mapper (GLM) and the Global Observing System for Total Lightning
NASA Technical Reports Server (NTRS)
Goodman, Steven J.; Blakeslee, R. J.; Koshak, W.; Buechler, D.; Carey, L.; Chronis, T.; Mach, D.; Bateman, M.; Peterson, H.; McCaul, E. W., Jr.;
2014-01-01
for the existing GOES system currently operating over the Western Hemisphere. New and improved instrument technology will support expanded detection of environmental phenomena, resulting in more timely and accurate forecasts and warnings. Advancements over current GOES include a new capability for total lightning detection (cloud and cloud-to-ground flashes) from the Geostationary Lightning Mapper (GLM), and improved temporal, spatial, and spectral resolution for the next generation Advanced Baseline Imager (ABI). The GLM will map total lightning continuously day and night with near-uniform spatial resolution of 8 km with a product latency of less than 20 sec over the Americas and adjacent oceanic regions. This will aid in forecasting severe storms and tornado activity, and convective weather impacts on aviation safety and efficiency among a number of potential applications. The GLM will help address the National Weather Service requirement for total lightning observations globally to support warning decision-making and forecast services. Science and application development along with pre-operational product demonstrations and evaluations at NWS national centers, forecast offices, and NOAA testbeds will prepare the forecasters to use GLM as soon as possible after the planned launch and check-out of GOES-R in 2016. New applications will use GLM alone, in combination with the ABI, or integrated (fused) with other available tools (weather radar and ground strike networks, nowcasting systems, mesoscale analysis, and numerical weather prediction models) in the hands of the forecaster responsible for issuing more timely and accurate forecasts and warnings.
Kim, Hae Jin; Song, Yong Ju; Kim, Young Kook; Jeoung, Jin Wook; Park, Ki Ho
2017-07-01
To evaluate functional progression in preperimetric glaucoma (PPG) with disc hemorrhage (DH) and to determine the time interval between the first-detected DH and development of glaucomatous visual field (VF) defect. A total of 87 patients who had been first diagnosed with PPG were enrolled. The medical records of PPG patients without DH (Group 1) and with DH (Group 2) were reviewed. When glaucomatous VF defect appeared, the time interval from the diagnosis of PPG to the development of VF defect was calculated and compared between the two groups. In group 2, the time intervals from the first-detected DH to VF defect of the single- and recurrent-DH were compared. Of the enrolled patients, 45 had DH in the preperimetric stage. The median time interval from the diagnosis of PPG to the development of VF defect was 73.3 months in Group 1, versus 45.4 months in Group 2 (P = 0.042). The cumulative probability of development of VF defect after diagnosis of PPG was significantly greater in Group 2 than in Group 1. The median time interval from first-detected DH to the development of VF defect was 37.8 months. The median time interval from DH to VF defect and cumulative probability of VF defect after DH did not show a statistical difference between single and recurrent-DH patients. The median time interval between the diagnosis of PPG and the development of VF defect was significantly shorter in PPG with DH. The VF defect appeared 37.8 months after the first-detected DH in PPG.
Abdella, Rana M A; Abdelmoaty, Hatem I; Elsherif, Rasha H; Sayed, Ahmed Mahmoud; Sherif, Nadine Alaa; Gouda, Hisham M; El Lithy, Ahmed; Almohamady, Maged; Abdelbar, Mostafa; Hosni, Ahmed Naguib; Magdy, Ahmed; Ma, Youssef
2015-06-02
To study the prevalence of Chlamydia infection in women with primary and secondary unexplained infertility using ELISA technique for antibody detection and real time, fully automated PCR for antigen detection and to explore its association with circulating antisperm antibodies (ASA). A total of 50 women with unexplained infertility enrolled in this case control study and a control group of 44 infertile women with a known cause of infertility. Endocervical specimens were collected for Chlamydia antigen detection using PCR and serum samples for antibodies detection. Circulating anti-sperm antibodies were detected using sperm antibody Latex Agglutination tests. The overall prevalence of Chlamydial infection in unexplained infertility cases as detected by both ELISA and PCR was 40 % (20/50). The prevalence of current Chlamydial genital infection as detected by real-time PCR was only 6.0 % (3/50); two of which were also IgM positive. Prevalence of ASA was 6.0 % (3/50); all were sero-negative for anti-C.trachomatis IgM and were PCR negative. The incidence of Chlamydial infection in Egyptian patients with unexplained infertility is relatively high. In the setting of fertility investigations; screening for anti. C.trachomatis antibodies using ELISA, and treatment of positive cases should be considered. The presence of circulating ASA does not correlate with the presence of old or current Chlamydia infection in women with unexplained infertility.
A method for real time detecting of non-uniform magnetic field
NASA Astrophysics Data System (ADS)
Marusenkov, Andriy
2015-04-01
The principle of measuring magnetic signatures for observing diverse objects is widely used in Near Surface work (unexploded ordnance (UXO); engineering & environmental; archaeology) and security and vehicle detection systems as well. As a rule, the magnitude of the signals to be measured is much lower than that of the quasi-uniform Earth magnetic field. Usually magnetometers for these purposes contain two or more spatially separated sensors to estimate the full tensor gradient of the magnetic field or, more frequently, only partial gradient components. The both types (scalar and vector) of magnetic sensors could be used. The identity of the scale factors and proper alignment of the sensitivity axes of the vector sensors are very important for deep suppression of the ambient field and detection of weak target signals. As a rule, the periodical calibration procedure is used to keep matching sensors' parameters as close as possible. In the present report we propose the technique for detection magnetic anomalies, which is almost insensitive to imperfect matching of the sensors. This method based on the idea that the difference signals between two sensors are considerably different when the instrument is rotated or moved in uniform and non-uniform fields. Due to the misfit of calibration parameters the difference signal observed at the rotation in the uniform field is similar to the total signal - the sum of the signals of both sensors. Zero change of the difference and total signals is expected, if the instrument moves in the uniform field along a straight line. In contrast, the same move in the non-uniform field produces some response of each of the sensors. In case one measures dB/dx and moves along x direction, the sensors signals is shifted in time with the lag proportional to the distance between sensors and the speed of move. It means that the difference signal looks like derivative of the total signal at move in the non-uniform field. So, using quite simple electronic schematic it is possible to detect the lag between the total and difference signals and to trigger alarms, when the instrument passes near a magnetized object. The proposed method was successfully applied in the two instruments: the low-power search coil magnetometer for vehicle detection system and the low-noise flux-gate magnetometer for magnetocardiograph. Author believes that this approach could be also useful for the fast inspection of the area during the engineering, archaeology, UXO surveys.
Measurement of the Total Cross Section of Uranium-Uranium Collisions at √{sNN} = 192 . 8 GeV
NASA Astrophysics Data System (ADS)
Baltz, A. J.; Fischer, W.; Blaskiewicz, M.; Gassner, D.; Drees, K. A.; Luo, Y.; Minty, M.; Thieberger, P.; Wilinski, M.; Pshenichnov, I. A.
2014-03-01
The total cross section of Uranium-Uranium at √{sNN} = 192 . 8 GeV has been measured to be 515 +/-13stat +/-22sys barn, which agrees with the calculated theoretical value of 487.3 barn within experimental error. That this total cross section is more than an order of magnitude larger than the geometric ion-ion cross section is primarily due to Bound-Free Pair Production (BFPP) and Electro-Magnetic Dissociation (EMD). Nearly all beam losses were due to geometric, BFPP and EMD collisions. This allowed the determination of the total cross section from the measured beam loss rates and luminosity. The beam loss rate is calculated from a time-dependent measurement of the total beam intensity. The luminosity is measured via the detection of neutron pairs in time-coincidence in the Zero Degree Calorimeters. Apart from a general interest in verifying the calculations experimentally, an accurate prediction of the losses created in the heavy ion collisions is of practical interest for the LHC, where collision products have the potential to quench cryogenically cooled magnets.
Park, Yongjung; Kim, Beom Seok; Choi, Kyu Hun; Shin, Dong Ho; Lee, Mi Jung; Cho, Yonggeun; Kim, Hyon-Suk
2012-01-01
A novel multiplex real-time PCR assay for concurrent detection of hepatitis viruses was evaluated for its clinical performance in screening patients with acute hepatitis. A total of 648 serum samples were collected from patients with acute symptoms of hepatitis. Concurrent detection of nucleic acids of HAV, HBV and HCV was performed using the Magicplex™ HepaTrio Real-time Detection test. Serum nucleic acid levels of HBV and HCV were also quantified by the Cobas® AmpliPrep/Cobas® TaqMan® (CAP/CTM) HBV and HCV tests. Patients' medical records were also reviewed. Concordance rates between the results from the HepaTrio and the CAP/CTM tests for the detection of HBV and HCV were 94.9% (k = 0.88) and 99.2% (k = 0.98), respectively. The cycle threshold values with the HepaTrio test were also correlated well with the levels of HBV DNA (r = -0.9230) and HCV RNA (r = -0.8458). The sensitivity and specificity of the HepaTrio test were 93.8% and 98.2%, respectively, for detecting HBV infection, and 99.1% and 100.0%, respectively, for HCV infection. For the HepaTrio test, 21 (3.2%) cases were positive for both HBV and HCV. Among the positive cases, 6 (0.9%) were true coinfections. This test also detected 18 (2.8%) HAV positives. The HepaTrio test demonstrated good clinical performance and produced results that agreed well with those of the CAP/CTM assays, especially for the detection of HCV. This assay was also able to detect HAV RNA from anti-HAV IgM-positive individuals. Therefore, this new multiplex PCR assay could be useful for the concurrent detection of the three hepatitis viruses.
Noninvasive detection of skin cancers by measuring optical properties of tissues
NASA Astrophysics Data System (ADS)
Wang, Lihong V.; Jacques, Steven L.
1995-05-01
Skin cancer is the most frequently occurring cancer of all cancers. Each yea rover 500,000 new cases of skin cancer will be detected. A high percentage of skin cancers are diseases in which fatalities can be all but eliminated and morbidity reduced if detected early and treated properly. These skin lesions are distinguished generally by subjective visual inspection and their definitive diagnosis requires time-consuming expensive histopathological evaluation of excisional or incisional biopsies. In vivo experimental evidence published in the literature has shown that cancerous skin lesions have different total diffuse reflectance spectra than non- cancerous lesions or normal skin. Therefore, cancerous skin lesions may be differentiated from non-cancerous skin lesions by comparing the optical properties of the skin lesions with those of the surrounding normal skin sites, where the optical properties of the normal skin sites are used to account for different types of skin or different areas of skin. We have demonstrated that the effect of melanin concentration on the diffuse reflectance may be removed by extrapolating the reflectance at different wavelengths to an apparent pivot point. Because the concentration of melanin does not indicate malignancy, the removal of its effect is important to avoid false detection. The total diffuse reflectance depends on the albedo and anisotropy of tissues. Therefore, the total diffuse reflectance will remain the same as long as the anisotropy and the ratio between the absorption coefficient and the reduced scattering coefficient remain the same. Separating the absorption and scattering effects should enhance the detection sensitivity of skin cancers.
Garrido Elustondo, Sofía; Sánchez Padilla, Elisabeth; Ramírez Alesón, Victoria; González Hernández, Ma José; González Navarro, Andrés; López Gómez, Carlos
2008-01-01
Mammogram screening is the most effective method for the early detection of breast cancer. The objective of this study is to evaluate the degree of knowledge, the opinion and the participation in the early breast cancer detection program on the part of the family physicians of the Autonomous Community of Madrid. The population studied was comprised of family physicians from Madrid Health District Seven. An anonymous, self-administered questionnaire comprised of 30 questions grouped into physicians characteristics and opinion concerning the early breast cancer detection programs. A total of 46% of the physicians replied. A total of 94% of the physicians believed that it is their duty to inform their patients concerning preventive activities, including breast cancer screening, and 95% believed their advice to be useful for convincing women to have a mammogram. A total of 72% believed information to be lacking on this program. During the time when mammograms are being taken at their centres, 24% of the physicians surveyed always or almost always ask the women if they have any doubts or would like further information, 43% having set up appointments for them and 95% advising them to have a mammogram taken. The family physicians have a good opinion of the early breast cancer detection program and feel their advice to be effective for improving the participation in the program. They report lack of information and inform women about the program to only a small degree.
Ghodbane, Ramzi; Asmar, Shady; Betzner, Marlena; Linet, Marie; Pierquin, Joseph; Raoult, Didier; Drancourt, Michel
2015-08-01
Culture remains the cornerstone of diagnosis for pulmonary tuberculosis, but the fastidiousness of Mycobacterium tuberculosis may delay culture-based diagnosis for weeks. We evaluated the performance of real-time high-resolution imaging for the rapid detection of M. tuberculosis colonies growing on a solid medium. A total of 50 clinical specimens, including 42 sputum specimens, 4 stool specimens, 2 bronchoalveolar lavage fluid specimens, and 2 bronchial aspirate fluid specimens were prospectively inoculated into (i) a commercially available Middlebrook broth and evaluated for mycobacterial growth indirectly detected by measuring oxygen consumption (standard protocol) and (ii) a home-made solid medium incubated in an incubator featuring real-time high-resolution imaging of colonies (real-time protocol). Isolates were identified by Ziehl-Neelsen staining and matrix-assisted laser desorption ionization-time of flight mass spectrometry. Use of the standard protocol yielded 14/50 (28%) M. tuberculosis isolates, which is not significantly different from the 13/50 (26%) M. tuberculosis isolates found using the real-time protocol (P = 1.00 by Fisher's exact test), and the contamination rate of 1/50 (2%) was not significantly different from the contamination rate of 2/50 (4%) using the real-time protocol (P = 1.00). The real-time imaging protocol showed a 4.4-fold reduction in time to detection, 82 ± 54 h versus 360 ± 142 h (P < 0.05). These preliminary data give the proof of concept that real-time high-resolution imaging of M. tuberculosis colonies is a new technology that shortens the time to growth detection and the laboratory diagnosis of pulmonary tuberculosis. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Time-evolution of uniform momentum zones in a turbulent boundary layer
NASA Astrophysics Data System (ADS)
Laskari, Angeliki; Hearst, R. Jason; de Kat, Roeland; Ganapathisubramani, Bharathram
2016-11-01
Time-resolved planar particle image velocimetry (PIV) is used to analyse the organisation and evolution of uniform momentum zones (UMZs) in a turbulent boundary layer. Experiments were performed in a recirculating water tunnel on a streamwise-wall-normal plane extending approximately 0 . 5 δ × 1 . 8 δ , in x and y, respectively. In total 400,000 images were captured and for each of the resulting velocity fields, local peaks in the probability density distribution of the streamwise velocity were detected, indicating the instantaneous presence of UMZs throughout the boundary layer. The main characteristics of these zones are outlined and more specifically their velocity range and wall-normal extent. The variation of these characteristics with wall normal distance and total number of zones are also discussed. Exploiting the time information available, time-scales of zones that have a substantial coherence in time are analysed and results show that the zones' lifetime is dependent on both their momentum deficit level and the total number of zones present. Conditional averaging of the flow statistics seems to further indicate that a large number of zones is the result of a wall-dominant mechanism, while the opposite implies an outer-layer dominance.
Guo, Lian-Xian; Zhang, Gui-Wei; Wang, Jia-Ting; Zhong, Yue-Ping; Huang, Zhi-Gang
2018-04-26
This study sought to determine the concentration and distribution of arsenic (As) species in Ophiocordyceps sinensis ( O. sinensis ), and to assess its edible hazard for long term consumption. The total arsenic concentrations, measured through inductively coupled plasma mass spectrometry (ICP-MS), ranged from 4.00 mg/kg to 5.25 mg/kg. As determined by HPLC-ICP-MS, the most concerning arsenic species—AsB, MMA V , DMA V , As V , and As Ш —were either not detected (MMA V and DMA V ) or were detected as minor As species (AsB: 1.4⁻2.9%; As V : 1.3⁻3.2%, and As Ш : 4.1⁻6.0%). The major components were a cluster of unknown organic As (uAs) compounds with As Ш , which accounted for 91.7⁻94.0% of the As content. Based on the H₂O₂ test and the chromatography behavior, it can be inferred that, the uAs might not be toxic organic As. Estimated daily intake ( EDI) , hazard quotient ( HQ ), and cancer risk ( CR ) caused by the total As content; the sum of inorganic As (iAs) and uAs, namely i+uAs; and iAs exposure from long term O. sinensis consumption were calculated and evaluated through equations from the US Environmental Protection Agency and the uncertainties were analyzed by Monte-Carlo Simulation (MCS). EDI total As and EDI i+uAs are approximately ten times more than EDI iAs ; HQ total As and HQ i+u As > 1 while HQ i As < 1; and CR total As and CR i+uAs > 1 × 10 −4 while CR iAs < 1 × 10 −4 . Thus, if the uAs is non-toxic, there is no particular risk to local consumers and the carcinogenic risk is acceptable for consumption of O. sinensis because the concentration of toxic iAs is very low.
BEACH Act amendment to Clean Water Act requires EPA to establish more expeditious methods for the timely detection of pathogens and pathogen indicators in coastal waters New methods should demonstrate utility for and be compatible with all CWA 304(a) criteria needs including:...
Enhanced X-ray Activity of the UHBL Source 1ES 0033+595
NASA Astrophysics Data System (ADS)
Kapanadze, Bidzina
2018-04-01
The TeV-detected ultra-high-energy peaked BL Lacertae source (UHBL) 1ES 0033+595 was observed 87 times with X-Ray Telescope (XRT) onboard the Neil Geherels Swift Observatory since 2005 April 1 with a total exposure of 117 ks (Mostly, in the framework of our ToO requests).
Long-term kinematics and sediment flux of an active earthflow, Eel River, California
B. H. Mackey; J. J. Roering; J. A. McKean
2009-01-01
Although earthflows are the dominant erosion mechanism in many mountainous landscapes, estimates of long-term earthflow-driven sediment flux remain elusive because landslide displacement data are typically limited to contemporary time periods. Combining high-resolution topography from airborne LiDAR (light detection and ranging), total station surveying, orthorectified...
Purriños, Laura; Franco, Daniel; Carballo, Javier; Lorenzo, José M
2012-12-01
The effect of the length of salting time on volatile compounds throughout the manufacture of dry-cured "lacón" was studied using a purge-and-trap extraction and GC/MS analysis. For this study, six treatments of "lacón" were salted with different amounts of salt (LS (3 days of salting), MS (4 days of salting) and HS (5 days of salting)). The total area of volatile compounds increased significantly (P<0.001) as the length of salting time increased. Significant differences were found for the total area of all aldehydes for each salting time at the end of process. Hexanal presented the most relative abundance, showing highest content in HS treatments while LS treatments showed the lowest one at the end of salting, post-salting and drying-ripening stage. The influence of salting time on the content of 3-Octen-2-one was significant on salting stage (P<0.001) and drying-ripening stage (P<0.01). The salting time affected (P<0.001) the relative abundance of esters at the end of salting and at the end of drying-ripening stage. The salting time affected significantly (P<0.001) on alcohols content at the end of drying-ripening process. However, no significant effect of salt level (P>0.05) was detected on total hydrocarbons and total furans at the end of process. Copyright © 2012 Elsevier Ltd. All rights reserved.
Babu, Binoy; Jeyaprakash, Ayyamperumal; Jones, Debra; Schubert, Timothy S; Baker, Carlye; Washburn, Brian K; Miller, Steven H; Poduch, Kristina; Knox, Gary W; Ochoa-Corona, Francisco M; Paret, Mathews L
2016-09-01
Rose rosette virus (RRV), belonging to the genus Emaravirus, is a highly destructive pathogen that causes rose rosette disease. The disease is a major concern for the rose industry in the U.S. due to the lack of highly sensitive methods for early detection of RRV. This is critical, as early identification of the infected plants and eradication is necessary in minimizing the risks associated with the spread of the disease. A highly reliable, specific and sensitive detection assay is thus required to test and confirm the presence of RRV in suspected plant samples. In this study a TaqMan real-time reverse transcription-polymerase chain reaction (RT-PCR) assay was developed for the detection of RRV from infected roses, utilizing multiple gene targets. Four pairs of primers and probes; two of them (RRV_2-1 and RRV_2-2) based on the consensus sequences of the glycoprotein gene (RNA2) and the other two (RRV_3-2 and RRV_3-5) based on the nucleocapsid gene (RNA3) were designed. The specificity of the primers and probes was evaluated against other representative viruses infecting roses, belonging to the genera Alfamovirus, Cucumovirus, Ilarvirus, Nepovirus, Tobamovirus, and Tospovirus and one Emaravirus (Wheat mosaic virus). Dilution assays using the in vitro transcripts (spiked with total RNA from healthy plants, and non-spiked) showed that all the primers and probes are highly sensitive in consistently detecting RRV with a detection limit of 1 fg. Testing of the infected plants over a period of time (three times in monthly intervals) indicated high reproducibility, with the primer/probe RRV_3-5 showing 100% positive detection, while RRV_2-1, RRV_2-2 and RRV_3-2 showed 90% positive detection. The developed real-time RT-PCR assay is reliable, highly sensitive, and can be easily used in diagnostic laboratories for testing and confirmation of RRV. Copyright © 2016 Elsevier B.V. All rights reserved.
Fischbach, Wolfgang; Elsome, Rory; Amlani, Bharat
2018-06-05
Colonoscopy provides less protection from colorectal cancer in the right colon than the left. Areas covered: This review examines patient outcomes and colonoscopy success rates to identify factors that limit the protective effect of colonoscopy in the right colon. The MEDLINE and Embase databases were searched for literature from 2000 onwards, on the long-term outcomes and differences in screening practice between the right and left colon. In total, 12 systematic reviews (including nine meta-analyses) and 44 primary data records were included. Differences in patient outcomes and colonoscopy practice were identified between the right and left colon, suggesting that several factors, many of which disproportionally affect the right colon, impact lesion detection rates. Shorter withdrawal times reduce detection rates, while longer times significantly increase detection; mostly of adenomas in the right colon. Colonoscope attachments often only show a significant improvement in detection rates in the right colon, suggesting detection is more challenging due to visibility of the right colonic mucosa. Higher bowel cleansing grades significantly improve detection rates in the right colon compared to the left. Expert commentary: These findings confirm the need for continued improvement of colonoscopy effectiveness, and obligatory quality assessment, overall and especially in the right colon.
Simultaneous capture and sequential detection of two malarial biomarkers on magnetic microparticles.
Markwalter, Christine F; Ricks, Keersten M; Bitting, Anna L; Mudenda, Lwiindi; Wright, David W
2016-12-01
We have developed a rapid magnetic microparticle-based detection strategy for malarial biomarkers Plasmodium lactate dehydrogenase (pLDH) and Plasmodium falciparum histidine-rich protein II (PfHRPII). In this assay, magnetic particles functionalized with antibodies specific for pLDH and PfHRPII as well as detection antibodies with distinct enzymes for each biomarker are added to parasitized lysed blood samples. Sandwich complexes for pLDH and PfHRPII form on the surface of the magnetic beads, which are washed and sequentially re-suspended in detection enzyme substrate for each antigen. The developed simultaneous capture and sequential detection (SCSD) assay detects both biomarkers in samples as low as 2.0parasites/µl, an order of magnitude below commercially available ELISA kits, has a total incubation time of 35min, and was found to be reproducible between users over time. This assay provides a simple and efficient alternative to traditional 96-well plate ELISAs, which take 5-8h to complete and are limited to one analyte. Further, the modularity of the magnetic bead-based SCSD ELISA format could serve as a platform for application to other diseases for which multi-biomarker detection is advantageous. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Figueredo, Diego de Siqueira; Barbosa, Mayara Rodrigues; Coimbra, Daniel Gomes; Dos Santos, José Luiz Araújo; Costa, Ellyda Fernanda Lopes; Koike, Bruna Del Vechio; Alexandre Moreira, Magna Suzana; de Andrade, Tiago Gomes
2018-03-01
Recent studies have shown that transcriptomes from different tissues present circadian oscillations. Therefore, the endogenous variation of total RNA should be considered as a potential bias in circadian studies of gene expression. However, normalization strategies generally include the equalization of total RNA concentration between samples prior to cDNA synthesis. Moreover, endogenous housekeeping genes (HKGs) frequently used for data normalization may exhibit circadian variation and distort experimental results if not detected or considered. In this study, we controlled experimental conditions from the amount of initial brain tissue samples through extraction steps, cDNA synthesis, and quantitative real time PCR (qPCR) to demonstrate a circadian oscillation of total RNA concentration. We also identified that the normalization of the RNA's yield affected the rhythmic profiles of different genes, including Per1-2 and Bmal1. Five widely used HKGs (Actb, Eif2a, Gapdh, Hprt1, and B2m) also presented rhythmic variations not detected by geNorm algorithm. In addition, the analysis of exogenous microRNAs (Cel-miR-54 and Cel-miR-39) spiked during RNA extraction suggests that the yield was affected by total RNA concentration, which may impact circadian studies of small RNAs. The results indicate that the approach of tissue normalization without total RNA equalization prior to cDNA synthesis can avoid bias from endogenous broad variations in transcript levels. Also, the circadian analysis of 2 -Cycle threshold (Ct) data, without HKGs, may be an alternative for chronobiological studies under controlled experimental conditions.
Suwancharoen, Duangjai; Sittiwicheanwong, Busara; Wiratsudakul, Anuwat
2016-09-01
Leptospirosis has been one of the worldwide zoonotic diseases caused by pathogenic Leptospira spp. Many molecular techniques have consecutively been developed to detect such pathogen including loop-mediated isothermal amplification method (LAMP). The objectives of this study were to evaluate the diagnostic accuracy of LAMP assay and real-time PCR using bacterial culture as the gold standard and to assess the agreement among these three tests using Cohen's kappa statistics. In total, 533 urine samples were collected from 266 beef and 267 dairy cattle reared in central region of Thailand. Sensitivity and specificity of LAMP were 96.8% (95% CI 81.5-99.8) and 97.0% (95% CI 94.9-98.2), respectively. The accuracy of LAMP (97.0%) was significantly higher than that of real-time PCR (91.9%) at 95% CI. With Cohen's kappa statistics, culture method and LAMP were substantially agreed with each other (77.4%), whereas real-time PCR only moderately agreed with culture (47.7%) and LAMP (45.3%), respectively. Consequently, LAMP was more effective than real-time PCR in detecting Leptospira spp. in the urine of cattle. Besides, LAMP had less cost and was simpler than real-time PCR. Thus, LAMP was an excellent alternative for routine surveillance of leptospirosis in cattle.
Bodien, Yelena G; Carlowicz, Cecilia A; Chatelle, Camille; Giacino, Joseph T
2016-03-01
To describe the sensitivity and specificity of Coma Recovery Scale-Revised (CRS-R) total scores in detecting conscious awareness. Data were retrospectively extracted from the medical records of patients enrolled in a specialized disorders of consciousness (DOC) program. Sensitivity and specificity analyses were completed using CRS-R-derived diagnoses of minimally conscious state (MCS) or emerged from minimally conscious state (EMCS) as the reference standard for conscious awareness and the total CRS-R score as the test criterion. A receiver operating characteristic curve was constructed to demonstrate the optimal CRS-R total cutoff score for maximizing sensitivity and specificity. Specialized DOC program. Patients enrolled in the DOC program (N=252, 157 men; mean age, 49y; mean time from injury, 48d; traumatic etiology, n=127; nontraumatic etiology, n=125; diagnosis of coma or vegetative state, n=70; diagnosis of MCS or EMCS, n=182). Not applicable. Sensitivity and specificity of CRS-R total scores in detecting conscious awareness. A CRS-R total score of 10 or higher yielded a sensitivity of .78 for correct identification of patients in MCS or EMCS, and a specificity of 1.00 for correct identification of patients who did not meet criteria for either of these diagnoses (ie, were diagnosed with vegetative state or coma). The area under the curve in the receiver operating characteristic curve analysis is .98. A total CRS-R score of 10 or higher provides strong evidence of conscious awareness but resulted in a false-negative diagnostic error in 22% of patients who demonstrated conscious awareness based on CRS-R diagnostic criteria. A cutoff score of 8 provides the best balance between sensitivity and specificity, accurately classifying 93% of cases. The optimal total score cutoff will vary depending on the user's objective. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Determination of total sulfur content via sulfur-specific chemiluminescence detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kubala, S.W.; Campbell, D.N.; DiSanzo, F.P.
A specially designed system, based upon sulfur-specific chemiluminescence detection (SSCD), was developed to permit the determination of total sulfur content in a variety of samples. This type of detection system possesses several advantages such as excellent linearity and selectivity, low minimum detectable levels, and an equimolar response to various sulfur compounds. This paper will focus on the design and application of a sulfur-specific chemiluminescence detection system for use in determining total sulfur content in gasoline.
A rapid beverage intake questionnaire can detect changes in beverage intake.
Hedrick, Valisa E; Comber, Dana L; Ferguson, Katherine E; Estabrooks, Paul A; Savla, Jyoti; Dietrich, Andrea M; Serrano, Elena; Davy, Brenda M
2013-01-01
Attention on beverage intake, specifically sugar-sweetened beverages (SSB), has increased in recent years. A brief valid, reliable and sensitive assessment tool for quantifying beverage consumption and determining its influence on weight status could help to advance research on this topic. The valid and reliable 15-item beverage questionnaire (BEVQ-15) estimates mean daily intake of water, SSB and total beverages (g, kcal) across multiple beverage categories. to determine the ability of the BEVQ-15 to detect changes in beverage intake over time. Participants (n=70; age=37±2 yr; BMI=24.5±0.4 kg/m(2)) underwent two randomly assigned 30-day periods (intervention, increased water and fruit juice consumption; control, increased solid fruit consumption), with a 30-day washout phase between feeding periods. The BEVQ-15 was administered at the beginning and end of each period. Reliability was assessed by Pearson's correlations, paired sample t tests and Cronbach's alpha. Paired sample t tests and repeated measures ANOVA were used to evaluate sensitivity to change. Sixty-nine participants completed all study sessions. Reliability was acceptable for most beverages (range: R(2)=0.52-0.95, P<0.001), but not for energy drinks. Increases in water (g), juice (kcal, g) and total beverage (g) were detected during the intervention period (P<0.001); no changes in these variables were detected in the control period. The BEVQ-15 demonstrates the ability to detect changes in beverage intake over time. This brief (~2 min), self-administered, valid, reliable and sensitive beverage intake assessment tool may be used by researchers and practitioners who evaluate and intervene upon beverage intake patterns in adults. Published by Elsevier Ltd.
Linhares, D C L; Cano, J P; Torremorell, M; Morrison, R B
2014-09-01
To control and eliminate porcine reproductive and respiratory syndrome virus (PRRSv) from breeding herds, some veterinarians adopt a strategy called load-close-expose which consists of interrupting replacement pig introduction for several months and exposing the pigs to a replicating PRRSv. This was a prospective quasi-experiment that followed 61 breeding herds acutely infected with PRRSv that adopted one of two exposure programs: modified-live virus (MLV) vaccine or live-resident virus inoculation (LVI). Treatment groups (load-close-expose with MLV or LVI) were compared for: (a) time-to-PRRSv stability (TTS), defined as time in weeks it took to produce PRRSv negative pigs at weaning; (b) the time-to-baseline production (TTBP), defined using statistical process control methods to represent time to recover to the number of pigs weaned per week that herds had prior to PRRSv-detection; and (c) the total production loss in terms of number of pigs weaned per week. TTS and TTBP were compared between treatments using survival analysis. Day 1 of the program was considered to be the day that treatment was administered. Sampling at herds consisted of bleeding 30 due-to-wean piglets on a monthly basis. Serum was tested for PRRSv RNA by RT-PCR. Herds in which PRRSv was not detected over a 90-day period were classified as reaching stability. Multivariate analysis using proportional hazards regression was performed adjusting the effect of treatment on TTBP and TTS to 'severity of PRRSv infection', 'number of whole-herd exposures', 'days from PRRSv-detection to intervention', 'prior PRRSv-infection status' and 'veterinary clinic associated with the herd'. Total loss was compared between groups using multivariate regression analysis adjusted by selected covariates. The median TTS among participating herds was 26.6 weeks (25th to 75th percentile, 21.6-33.0 weeks). The overall TTBP was 16.5 weeks (range 0-29 weeks). The magnitude of production losses following whole-herd exposure averaged 2217 pigs not weaned/1000 sows and was correlated with TTBP. Herds in the MLV group recovered production sooner and had less total loss than herds in the LVI group. TTBP and TTS were significantly shorter and the total loss was significantly less in herds assisted by a specific veterinary clinic and herds that were infected with PRRSv in the 3 years prior to the study. This study provided new metrics to assist veterinarians to decide between methods of exposure to control and eliminate PRRSv from breeding herds. Copyright © 2014 Elsevier B.V. All rights reserved.
Is the use of underwater polarized light by fish restricted to crepuscular time periods?
Novales Flamarique, I; Hawryshyn, C W
1997-04-01
We measured the spectral distributions of the underwater total and polarized light fields in the upper photic zone of meso-eutrophic waters (i.e., blue-green waters containing medium to high chlorophyll a concentrations). Per cent polarization levels during the day were always lower than 40%, but at crepuscular times these values could increase to 67%. A corresponding change occurred in the spectral distribution, with proportionately more shorter wavelength photons contributing to the total spectrum during crepuscular periods. Electrophysiological recordings from the optic nerve of rainbow trout subjected to light stimuli of varying polarization percentages show that the animal's threshold for detecting polarized light is between 63 and 72%. These physiological findings suggest that the use of water-induced polarized light cues by rainbow trout and similar percomorph fish should be restricted to crepuscular time periods.
Time Correlations of Lightning Flash Sequences in Thunderstorms Revealed by Fractal Analysis
NASA Astrophysics Data System (ADS)
Gou, Xueqiang; Chen, Mingli; Zhang, Guangshu
2018-01-01
By using the data of lightning detection and ranging system at the Kennedy Space Center, the temporal fractal and correlation of interevent time series of lightning flash sequences in thunderstorms have been investigated with Allan factor (AF), Fano factor (FF), and detrended fluctuation analysis (DFA) methods. AF, FF, and DFA methods are powerful tools to detect the time-scaling structures and correlations in point processes. Totally 40 thunderstorms with distinguishing features of a single-cell storm and apparent increase and decrease in the total flash rate were selected for the analysis. It is found that the time-scaling exponents for AF (
Determination of Ivermectin in Medicated Feeds by Liquid Chromatography with Fluorescence Detection
2013-01-01
A labour- and time-effective analytical procedure for determination of ivermectin in medicated feed at recommended level of 2.0 mg kg−1 has been developed and validated. The analyte was extracted from grinded feed samples with acetonitrile and derivatisated with N-methylimidazole and trifluoracetic anhydride. The fluorescent derivatives were analysed by liquid chromatography method using C8 column. The isocratic conditions using acetonitrile, methanol, water, and tetrahydrofuran were applied. Fluorescence detection was performed at 365 nm (excitation) and 475 nm (emission) wavelengths. The total analysis time was 10 min. The validation results of the method (within-laboratory reproducibility 4.0% CV, mean recovery 100.1%) confirm the appropriate precision and accuracy of the developed method. PMID:24453835
Environmental Sampling for Avian Influenza A(H7N9) in Live-Poultry Markets in Guangdong, China
Kang, Min; He, Jianfeng; Song, Tie; Rutherford, Shannon; Wu, Jie; Lin, Jinyan; Huang, Guofeng; Tan, Xiaohua; Zhong, Haojie
2015-01-01
Background To provide an increased understanding of avian influenza A(H7N9) activity in live-poultry market in space and time and hence improve H7N9 epidemic control, an ongoing environmental sampling program in multiple live-poultry markets across Guangdong, China was conducted during March 2013–June 2014. Methods A total of 625 live-poultry markets throughout 21 prefecture areas took part in the study. A total of 10 environmental sites in markets for sampling were identified to represent 4 different poultry-related activity areas. At least 10 environmental samples were collected from each market every month. The real time RT-PCR was performed to detect the avian influenza A(H7N9) virus. Field survey was conducted to investigate the sanitation status of live-poultry markets. Results There were 109 human infections with H7N9 avian influenza in Guangdong, of which 37 (34%) died. A total of 18741 environmental swabs were collected and subjected to real-time RT-PCR test, of which 905(4.83%) were found positive for H7N9 virus. There were 201 (32.16%) markets affected by H7N9 in 16 prefecture areas. The detection of H7N9 virus in markets spiked in winter months. 63.33% markets (38/60) had no physical segregation for poultry holding, slaughter or sale zones. Closing live-poultry market significantly decreased the H7N9 detection rate from 14.83% (112/755) to 1.67% (5/300). Conclusions This study indicates the importance of live-poultry market surveillance based on environmental sampling for H7N9 Avian Influenza control. Improving live-poultry market management and sanitation and changing consumer practices are critical to reduce the risk of H7N9 infection. PMID:25933138
Continuous glucose monitoring: quality of hypoglycaemia detection.
Zijlstra, E; Heise, T; Nosek, L; Heinemann, L; Heckermann, S
2013-02-01
To evaluate the accuracy of a (widely used) continuous glucose monitoring (CGM)-system and its ability to detect hypoglycaemic events. A total of 18 patients with type 1 diabetes mellitus used continuous glucose monitoring (Guardian REAL-Time CGMS) during two 9-day in-house periods. A hypoglycaemic threshold alarm alerted patients to sensor readings <70 mg/dl. Continuous glucose monitoring sensor readings were compared to laboratory reference measurements taken every 4 h and in case of a hypoglycaemic alarm. A total of 2317 paired data points were evaluated. Overall, the mean absolute relative difference (MARD) was 16.7%. The percentage of data points in the clinically accurate or acceptable Clarke Error Grid zones A + B was 94.6%. In the hypoglycaemic range, accuracy worsened (MARD 38.8%) leading to a failure to detect more than half of the true hypoglycaemic events (sensitivity 37.5%). Furthermore, more than half of the alarms that warn patients for hypoglycaemia were false (false alert rate 53.3%). Above the low alert threshold, the sensor confirmed 2077 of 2182 reference values (specificity 95.2%). Patients using continuous glucose monitoring should be aware of its limitation to accurately detect hypoglycaemia. © 2012 Blackwell Publishing Ltd.
Paschoal, Fernando Mendes; de Almeida Lins Ronconi, Karla; de Lima Oliveira, Marcelo; Nogueira, Ricardo de Carvalho; Paschoal, Eric Homero Albuquerque; Teixeira, Manoel Jacobsen; Figueiredo, Eberval Gadelha; Bor-Seng-Shu, Edson
2015-01-01
Introduction. Cerebral emboli may occur in subarachnoid hemorrhage (SAH) and intracranial aneurysm surgery. Although embolic signs (ES) have been reported in SAH, their origin remains unclear. The aim of this study was to report the detection of ES during routine TCD monitoring in patients with aneurysmal SAH. Methods. A total of 105 patients with aneurysmal SAH were submitted to TCD evaluation. Patients were monitored almost daily (5 times per week). In each monitoring session, one experienced operator performed TCD to detect or assess vasospasm and ES in arteries of the Willis polygon. Results. Four patients out of a total of 105 patients with aneurysmal SAH were found to present spontaneous cerebral embolization during routine TCD monitoring. The average age of the 4 patients (mean ± standard deviation) was 59.5 ± 8.34 years (range 49–68 ys); female patients predominated representing 75% (3/4) of subjects. Conclusion. Although detection of ES was relatively rare in this study, rates of emboli occurrence may be higher under systematic monitoring. The detection of ES after SAH surgery reinforces the need to study the role of embolus in this condition and may be an indicator for prophylactic antithrombotic treatment. PMID:25893190
NASA Technical Reports Server (NTRS)
Waller, Jess M.; Williams, James H.; Fries, Joseph (Technical Monitor)
1999-01-01
The permeation resistance of chlorinated polyethylene (CPE) used in totally encapsulating chemical protective suits against the aerospace fuels hydrazine, monomethylhydrazine, and uns-dimethylhydrazine was determined by measuring the breakthrough time (BT) and time-averaged vapor transmission rate (VTR) using procedures consistent with ASTM F 739 and ASTM F 1383. Two exposure scenarios were simulated: a 2 hour (h) fuel vapor exposure, and a liquid fuel "splash" followed by a 2 h vapor exposure. To simulate internal suit pressure during operation, a positive differential pressure of 0.3 in. water (75 Pa) on the collection side of the permeation apparatus was used. Using the available data, a model was developed to estimate propellant concentrations inside an air-line fed, totally encapsulating chemical protective suit. Concentrations were calculated under simulated conditions of fixed vapor transmission rate, variable breathing air flow rate, and variable splash exposure area. Calculations showed that the maximum allowable permeation rates of hydrazine fuels through CPE were of the order of 0.05 to 0.08 ng/sq cm min for encapsulating suits with low breathing air flow rates (of the order of 5 scfm or 140 L min-1). Above these permeation rates, the 10 parts-per-billion (ppb) threshold limit value time-weighted average could be exceeded. To evaluate suit performance at 10 ppb threshold-limiting value/time-weighted average level concentrations, use of a sensitive analytical method such as cation exchange high performance liquid chromatography with amperometric detection was found to be essential. The analytical detection limit determines the lowest measurable VTR, which in turn governed the lowest per meant concentration that could be calculated inside the totally encapsulating chemical protective suit.
A NEW APPROACH TO IDENTIFYING THE MOST POWERFUL GRAVITATIONAL LENSING TELESCOPES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wong, Kenneth C.; Zabludoff, Ann I.; Ammons, S. Mark
2013-05-20
The best gravitational lenses for detecting distant galaxies are those with the largest mass concentrations and the most advantageous configurations of that mass along the line of sight. Our new method for finding such gravitational telescopes uses optical data to identify projected concentrations of luminous red galaxies (LRGs). LRGs are biased tracers of the underlying mass distribution, so lines of sight with the highest total luminosity in LRGs are likely to contain the largest total mass. We apply this selection technique to the Sloan Digital Sky Survey and identify the 200 fields with the highest total LRG luminosities projected withinmore » a 3.'5 radius over the redshift range 0.1 {<=} z {<=} 0.7. The redshift and angular distributions of LRGs in these fields trace the concentrations of non-LRG galaxies. These fields are diverse; 22.5% contain one known galaxy cluster and 56.0% contain multiple known clusters previously identified in the literature. Thus, our results confirm that these LRGs trace massive structures and that our selection technique identifies fields with large total masses. These fields contain two to three times higher total LRG luminosities than most known strong-lensing clusters and will be among the best gravitational lensing fields for the purpose of detecting the highest redshift galaxies.« less
Taye, Wondimeneh; Ayalew, Amare; Chala, Alemayehu; Dejene, Mashilla
2016-12-01
Natural contamination of sorghum grains by aflatoxin B 1 and total fumonisin and their producing toxigenic fungi has been studied. A total of 90 sorghum grain samples were collected from small-scale farmers' threshing floors and 5-6 months later from underground pits during 2013 harvest from three districts of East Hararghe, Ethiopia. Mycotoxin analysis was done using enzyme-linked immunosorbent assay (ELISA). The limits of detection were in the range 0.01-0.03 μg kg -1 . The results revealed that all sorghum grain samples were contaminated with both Aspergillus and Fusarium species. Aflatoxin B 1 was detected at levels ranging from
Orlando, James L.; Kuivila, Kathryn
2005-01-01
Concentrations of organic contaminants were determined in water samples collected at six surface-water sites located along the San Joaquin and Old Rivers during April through June 2001. Water samples were collected, coincident with salmon smolt caging studies conducted by researchers from the Bodega Marine Laboratory at the University of California at Davis to characterize exposure of the salmon smolt to organic contaminants. Sampling occurred prior to, during, and following the implementation of managed streamflow conditions on the San Joaquin and Old Rivers as part of the Vernalis Adaptive Management Plan. Thirteen pesticides were detected in water samples collected during this study, and at least five pesticides were detected in each sample. The total number of pesticide detections varied little between river systems and between sites, but the maximum concentrations of most pesticides occurred in San Joaquin River samples. The total number of pesticides detected varied little over the three time periods. However, during the period of managed streamflow, the fewest number of pesticides were detected at their absolute maximum concentration. Nine wastewater compounds were detected during this study. Suspended-sediment concentrations were similar for the San Joaquin and Old Rivers except during the period of managed streamflow conditions, when suspended-sediment concentration was higher at sites on the San Joaquin River than at sites on the Old River. Values for water parameters (pH, specific conductance, and hardness) were lowest during the period of managed flows.
Hautvast, Gilion L T F; Salton, Carol J; Chuang, Michael L; Breeuwer, Marcel; O'Donnell, Christopher J; Manning, Warren J
2012-05-01
Quantitative analysis of short-axis functional cardiac magnetic resonance images can be performed using automatic contour detection methods. The resulting myocardial contours must be reviewed and possibly corrected, which can be time-consuming, particularly when performed across all cardiac phases. We quantified the impact of manual contour corrections on both analysis time and quantitative measurements obtained from left ventricular short-axis cine images acquired from 1555 participants of the Framingham Heart Study Offspring cohort using computer-aided contour detection methods. The total analysis time for a single case was 7.6 ± 1.7 min for an average of 221 ± 36 myocardial contours per participant. This included 4.8 ± 1.6 min for manual contour correction of 2% of all automatically detected endocardial contours and 8% of all automatically detected epicardial contours. However, the impact of these corrections on global left ventricular parameters was limited, introducing differences of 0.4 ± 4.1 mL for end-diastolic volume, -0.3 ± 2.9 mL for end-systolic volume, 0.7 ± 3.1 mL for stroke volume, and 0.3 ± 1.8% for ejection fraction. We conclude that left ventricular functional parameters can be obtained under 5 min from short-axis functional cardiac magnetic resonance images using automatic contour detection methods. Manual correction more than doubles analysis time, with minimal impact on left ventricular volumes and ejection fraction. Copyright © 2011 Wiley Periodicals, Inc.
Li, Bing; Ju, Feng; Cai, Lin; Zhang, Tong
2015-09-01
The broad-spectrum profile of bacterial pathogens and their fate in sewage treatment plants (STPs) were investigated using high-throughput sequencing based metagenomic approach. This novel approach could provide a united platform to standardize bacterial pathogen detection and realize direct comparison among different samples. Totally, 113 bacterial pathogen species were detected in eight samples including influent, effluent, activated sludge (AS), biofilm, and anaerobic digestion sludge with the abundances ranging from 0.000095% to 4.89%. Among these 113 bacterial pathogens, 79 species were reported in STPs for the first time. Specially, compared to AS in bulk mixed liquor, more pathogen species and higher total abundance were detected in upper foaming layer of AS. This suggests that the foaming layer of AS might impose more threat to onsite workers and citizens in the surrounding areas of STPs because pathogens in foaming layer are easily transferred into air and cause possible infections. The high removal efficiency (98.0%) of total bacterial pathogens suggests that AS treatment process is effective to remove most bacterial pathogens. Remarkable similarities of bacterial pathogen compositions between influent and human gut indicated that bacterial pathogen profiles in influents could well reflect the average bacterial pathogen communities of urban resident guts within the STP catchment area.
2007-10-01
incorporation yields of 77As, 177Lu, 64Cu and 111In were comparable to the nanoparticles coated with the 64-76 KDa dextran. Specifically, the incorporation...ratios for a typical PET isotope 64Cu and 177Lu were about 50% and 73 %, respectively, with a total preparation time of 4 hours. After purification...radioisotope incorporation ratios for a typical PET isotope, 64Cu , and a SPECT isotope, 177Lu, were about 50% and 73 %, respectively, with a total
Neutron detection using a crystal ball calorimeter
NASA Astrophysics Data System (ADS)
Martem'yanov, M. A.; Kulikov, V. V.; Krutenkova, A. P.
2015-12-01
The program of experiments of the A2 Collaboration performed on a beam of tagged photons of the MAMI electron microtron in Mainz (Germany) includes precision measurements of the total and differential cross sections of the pion photoproduction on neutrons of a deuterium target. The determination of the detector ability to detect neutrons is undoubtedly one of the important problems of the experiment. The calorimetric system of the detector contains a segmented NaI Crystal Ball detector, which gives information about the position, energy, and detection time of neutral and charged particles in a wide angular range. In this work, we describe the measurement of the neutron detection efficiency in the energy range from 20 to 400MeV. The results are compared with BNL data obtained on a pion beam and proton target.
Bicycle weight and commuting time: randomised trial.
Groves, J
2010-12-09
To determine whether the author's 20.9 lb (9.5 kg) carbon frame bicycle reduced commuting time compared with his 29.75 lb (13.5 kg) steel frame bicycle. Randomised trial. Sheffield and Chesterfield, United Kingdom, between mid-January 2010 and mid-July 2010. One consultant in anaesthesia and intensive care. Total time to complete the 27 mile (43.5 kilometre) journey from Sheffield to Chesterfield Royal Hospital and back. The total distance travelled on the steel frame bicycle during the study period was 809 miles (1302 km) and on the carbon frame bicycle was 711 miles (1144 km). The difference in the mean journey time between the steel and carbon bicycles was 00:00:32 (hr:min:sec; 95% CI -00:03:34 to 00:02:30; P=0.72). A lighter bicycle did not lead to a detectable difference in commuting time. Cyclists may find it more cost effective to reduce their own weight rather than to purchase a lighter bicycle.
Dayrit, Fabian M; Buenafe, Olivia Erin M; Chainani, Edward T; de Vera, Ian Mitchelle S
2008-07-23
Phosphorus-31 nuclear magnetic resonance spectroscopy ( (31)P NMR) was used to differentiate virgin coconut oil (VCO) from refined, bleached, deodorized coconut oil (RCO). Monoglycerides (MGs), diglycerides (DGs), sterols, and free fatty acids (FFAs) in VCO and RCO were converted into dioxaphospholane derivatives and analyzed by (31)P NMR. On the average, 1-MG was found to be higher in VCO (0.027%) than RCO (0.019%). 2-MG was not detected in any of the samples down to a detection limit of 0.014%. On the average, total DGs were lower in VCO (1.55%) than RCO (4.10%). When plotted in terms of the ratio [1,2-DG/total DGs] versus total DGs, VCO and RCO samples grouped separately. Total sterols were higher in VCO (0.096%) compared with RCO (0.032%), and the FFA content was 8 times higher in VCO than RCO (0.127% vs 0.015%). FFA determination by (31)P NMR and titration gave comparable results. Principal components analysis shows that the 1,2-DG, 1,3-DG, and FFAs are the most important parameters for differentiating VCO from RCO.
Abbott, B P; Abbott, R; Abbott, T D; Acernese, F; Ackley, K; Adams, C; Adams, T; Addesso, P; Adhikari, R X; Adya, V B; Affeldt, C; Afrough, M; Agarwal, B; Agathos, M; Agatsuma, K; Aggarwal, N; Aguiar, O D; Aiello, L; Ain, A; Ajith, P; Allen, B; Allen, G; Allocca, A; Altin, P A; Amato, A; Ananyeva, A; Anderson, S B; Anderson, W G; Angelova, S V; Antier, S; Appert, S; Arai, K; Araya, M C; Areeda, J S; Arnaud, N; Arun, K G; Ascenzi, S; Ashton, G; Ast, M; Aston, S M; Astone, P; Atallah, D V; Aufmuth, P; Aulbert, C; AultONeal, K; Austin, C; Avila-Alvarez, A; Babak, S; Bacon, P; Bader, M K M; Bae, S; Baker, P T; Baldaccini, F; Ballardin, G; Ballmer, S W; Banagiri, S; Barayoga, J C; Barclay, S E; Barish, B C; Barker, D; Barkett, K; Barone, F; Barr, B; Barsotti, L; Barsuglia, M; Barta, D; Bartlett, J; Bartos, I; Bassiri, R; Basti, A; Batch, J C; Bawaj, M; Bayley, J C; Bazzan, M; Bécsy, B; Beer, C; Bejger, M; Belahcene, I; Bell, A S; Berger, B K; Bergmann, G; Bero, J J; Berry, C P L; Bersanetti, D; Bertolini, A; Betzwieser, J; Bhagwat, S; Bhandare, R; Bilenko, I A; Billingsley, G; Billman, C R; Birch, J; Birney, R; Birnholtz, O; Biscans, S; Biscoveanu, S; Bisht, A; Bitossi, M; Biwer, C; Bizouard, M A; Blackburn, J K; Blackman, J; Blair, C D; Blair, D G; Blair, R M; Bloemen, S; Bock, O; Bode, N; Boer, M; Bogaert, G; Bohe, A; Bondu, F; Bonilla, E; Bonnand, R; Boom, B A; Bork, R; Boschi, V; Bose, S; Bossie, K; Bouffanais, Y; Bozzi, A; Bradaschia, C; Brady, P R; Branchesi, M; Brau, J E; Briant, T; Brillet, A; Brinkmann, M; Brisson, V; Brockill, P; Broida, J E; Brooks, A F; Brown, D A; Brown, D D; Brunett, S; Buchanan, C C; Buikema, A; Bulik, T; Bulten, H J; Buonanno, A; Buskulic, D; Buy, C; Byer, R L; Cabero, M; Cadonati, L; Cagnoli, G; Cahillane, C; Bustillo, J Calderón; Callister, T A; Calloni, E; Camp, J B; Canepa, M; Canizares, P; Cannon, K C; Cao, H; Cao, J; Capano, C D; Capocasa, E; Carbognani, F; Caride, S; Carney, M F; Diaz, J Casanueva; Casentini, C; Caudill, S; Cavaglià, M; Cavalier, F; Cavalieri, R; Cella, G; Cepeda, C B; Cerdá-Durán, P; Cerretani, G; Cesarini, E; Chamberlin, S J; Chan, M; Chao, S; Charlton, P; Chase, E; Chassande-Mottin, E; Chatterjee, D; Cheeseboro, B D; Chen, H Y; Chen, X; Chen, Y; Cheng, H-P; Chia, H; Chincarini, A; Chiummo, A; Chmiel, T; Cho, H S; Cho, M; Chow, J H; Christensen, N; Chu, Q; Chua, A J K; Chua, S; Chung, A K W; Chung, S; Ciani, G; Ciolfi, R; Cirelli, C E; Cirone, A; Clara, F; Clark, J A; Clearwater, P; Cleva, F; Cocchieri, C; Coccia, E; Cohadon, P-F; Cohen, D; Colla, A; Collette, C G; Cominsky, L R; Constancio, M; Conti, L; Cooper, S J; Corban, P; Corbitt, T R; Cordero-Carrión, I; Corley, K R; Cornish, N; Corsi, A; Cortese, S; Costa, C A; Coughlin, M W; Coughlin, S B; Coulon, J-P; Countryman, S T; Couvares, P; Covas, P B; Cowan, E E; Coward, D M; Cowart, M J; Coyne, D C; Coyne, R; Creighton, J D E; Creighton, T D; Cripe, J; Crowder, S G; Cullen, T J; Cumming, A; Cunningham, L; Cuoco, E; Dal Canton, T; Dálya, G; Danilishin, S L; D'Antonio, S; Danzmann, K; Dasgupta, A; Da Silva Costa, C F; Dattilo, V; Dave, I; Davier, M; Davis, D; Daw, E J; Day, B; De, S; DeBra, D; Degallaix, J; De Laurentis, M; Deléglise, S; Del Pozzo, W; Demos, N; Denker, T; Dent, T; De Pietri, R; Dergachev, V; De Rosa, R; DeRosa, R T; De Rossi, C; DeSalvo, R; de Varona, O; Devenson, J; Dhurandhar, S; Díaz, M C; Di Fiore, L; Di Giovanni, M; Di Girolamo, T; Di Lieto, A; Di Pace, S; Di Palma, I; Di Renzo, F; Doctor, Z; Dolique, V; Donovan, F; Dooley, K L; Doravari, S; Dorrington, I; Douglas, R; Dovale Álvarez, M; Downes, T P; Drago, M; Dreissigacker, C; Driggers, J C; Du, Z; Ducrot, M; Dupej, P; Dwyer, S E; Edo, T B; Edwards, M C; Effler, A; Eggenstein, H-B; Ehrens, P; Eichholz, J; Eikenberry, S S; Eisenstein, R A; Essick, R C; Estevez, D; Etienne, Z B; Etzel, T; Evans, M; Evans, T M; Factourovich, M; Fafone, V; Fair, H; Fairhurst, S; Fan, X; Farinon, S; Farr, B; Farr, W M; Fauchon-Jones, E J; Favata, M; Fays, M; Fee, C; Fehrmann, H; Feicht, J; Fejer, M M; Fernandez-Galiana, A; Ferrante, I; Ferreira, E C; Ferrini, F; Fidecaro, F; Finstad, D; Fiori, I; Fiorucci, D; Fishbach, M; Fisher, R P; Fitz-Axen, M; Flaminio, R; Fletcher, M; Fong, H; Font, J A; Forsyth, P W F; Forsyth, S S; Fournier, J-D; Frasca, S; Frasconi, F; Frei, Z; Freise, A; Frey, R; Frey, V; Fries, E M; Fritschel, P; Frolov, V V; Fulda, P; Fyffe, M; Gabbard, H; Gadre, B U; Gaebel, S M; Gair, J R; Gammaitoni, L; Ganija, M R; Gaonkar, S G; Garcia-Quiros, C; Garufi, F; Gateley, B; Gaudio, S; Gaur, G; Gayathri, V; Gehrels, N; Gemme, G; Genin, E; Gennai, A; George, D; George, J; Gergely, L; Germain, V; Ghonge, S; Ghosh, Abhirup; Ghosh, Archisman; Ghosh, S; Giaime, J A; Giardina, K D; Giazotto, A; Gill, K; Glover, L; Goetz, E; Goetz, R; Gomes, S; Goncharov, B; González, G; Gonzalez Castro, J M; Gopakumar, A; Gorodetsky, M L; Gossan, S E; Gosselin, M; Gouaty, R; Grado, A; Graef, C; Granata, M; Grant, A; Gras, S; Gray, C; Greco, G; Green, A C; Gretarsson, E M; Groot, P; Grote, H; Grunewald, S; Gruning, P; Guidi, G M; Guo, X; Gupta, A; Gupta, M K; Gushwa, K E; Gustafson, E K; Gustafson, R; Halim, O; Hall, B R; Hall, E D; Hamilton, E Z; Hammond, G; Haney, M; Hanke, M M; Hanks, J; Hanna, C; Hannam, M D; Hannuksela, O A; Hanson, J; Hardwick, T; Harms, J; Harry, G M; Harry, I W; Hart, M J; Haster, C-J; Haughian, K; Healy, J; Heidmann, A; Heintze, M C; Heitmann, H; Hello, P; Hemming, G; Hendry, M; Heng, I S; Hennig, J; Heptonstall, A W; Heurs, M; Hild, S; Hinderer, T; Hoak, D; Hofman, D; Holt, K; Holz, D E; Hopkins, P; Horst, C; Hough, J; Houston, E A; Howell, E J; Hreibi, A; Hu, Y M; Huerta, E A; Huet, D; Hughey, B; Husa, S; Huttner, S H; Huynh-Dinh, T; Indik, N; Inta, R; Intini, G; Isa, H N; Isac, J-M; Isi, M; Iyer, B R; Izumi, K; Jacqmin, T; Jani, K; Jaranowski, P; Jawahar, S; Jiménez-Forteza, F; Johnson, W W; Jones, D I; Jones, R; Jonker, R J G; Ju, L; Junker, J; Kalaghatgi, C V; Kalogera, V; Kamai, B; Kandhasamy, S; Kang, G; Kanner, J B; Kapadia, S J; Karki, S; Karvinen, K S; Kasprzack, M; Katolik, M; Katsavounidis, E; Katzman, W; Kaufer, S; Kawabe, K; Kéfélian, F; Keitel, D; Kemball, A J; Kennedy, R; Kent, C; Key, J S; Khalili, F Y; Khan, I; Khan, S; Khan, Z; Khazanov, E A; Kijbunchoo, N; Kim, Chunglee; Kim, J C; Kim, K; Kim, W; Kim, W S; Kim, Y-M; Kimbrell, S J; King, E J; King, P J; Kinley-Hanlon, M; Kirchhoff, R; Kissel, J S; Kleybolte, L; Klimenko, S; Knowles, T D; Koch, P; Koehlenbeck, S M; Koley, S; Kondrashov, V; Kontos, A; Korobko, M; Korth, W Z; Kowalska, I; Kozak, D B; Krämer, C; Kringel, V; Krishnan, B; Królak, A; Kuehn, G; Kumar, P; Kumar, R; Kumar, S; Kuo, L; Kutynia, A; Kwang, S; Lackey, B D; Lai, K H; Landry, M; Lang, R N; Lange, J; Lantz, B; Lanza, R K; Lartaux-Vollard, A; Lasky, P D; Laxen, M; Lazzarini, A; Lazzaro, C; Leaci, P; Leavey, S; Lee, C H; Lee, H K; Lee, H M; Lee, H W; Lee, K; Lehmann, J; Lenon, A; Leonardi, M; Leroy, N; Letendre, N; Levin, Y; Li, T G F; Linker, S D; Littenberg, T B; Liu, J; Lo, R K L; Lockerbie, N A; London, L T; Lord, J E; Lorenzini, M; Loriette, V; Lormand, M; Losurdo, G; Lough, J D; Lousto, C O; Lovelace, G; Lück, H; Lumaca, D; Lundgren, A P; Lynch, R; Ma, Y; Macas, R; Macfoy, S; Machenschalk, B; MacInnis, M; Macleod, D M; Magaña Hernandez, I; Magaña-Sandoval, F; Magaña Zertuche, L; Magee, R M; Majorana, E; Maksimovic, I; Man, N; Mandic, V; Mangano, V; Mansell, G L; Manske, M; Mantovani, M; Marchesoni, F; Marion, F; Márka, S; Márka, Z; Markakis, C; Markosyan, A S; Markowitz, A; Maros, E; Marquina, A; Martelli, F; Martellini, L; Martin, I W; Martin, R M; Martynov, D V; Mason, K; Massera, E; Masserot, A; Massinger, T J; Masso-Reid, M; Mastrogiovanni, S; Matas, A; Matichard, F; Matone, L; Mavalvala, N; Mazumder, N; McCarthy, R; McClelland, D E; McCormick, S; McCuller, L; McGuire, S C; McIntyre, G; McIver, J; McManus, D J; McNeill, L; McRae, T; McWilliams, S T; Meacher, D; Meadors, G D; Mehmet, M; Meidam, J; Mejuto-Villa, E; Melatos, A; Mendell, G; Mercer, R A; Merilh, E L; Merzougui, M; Meshkov, S; Messenger, C; Messick, C; Metzdorff, R; Meyers, P M; Miao, H; Michel, C; Middleton, H; Mikhailov, E E; Milano, L; Miller, A L; Miller, B B; Miller, J; Millhouse, M; Milovich-Goff, M C; Minazzoli, O; Minenkov, Y; Ming, J; Mishra, C; Mitra, S; Mitrofanov, V P; Mitselmakher, G; Mittleman, R; Moffa, D; Moggi, A; Mogushi, K; Mohan, M; Mohapatra, S R P; Montani, M; Moore, C J; Moraru, D; Moreno, G; Morriss, S R; Mours, B; Mow-Lowry, C M; Mueller, G; Muir, A W; Mukherjee, Arunava; Mukherjee, D; Mukherjee, S; Mukund, N; Mullavey, A; Munch, J; Muñiz, E A; Muratore, M; Murray, P G; Napier, K; Nardecchia, I; Naticchioni, L; Nayak, R K; Neilson, J; Nelemans, G; Nelson, T J N; Nery, M; Neunzert, A; Nevin, L; Newport, J M; Newton, G; Ng, K K Y; Nguyen, T T; Nichols, D; Nielsen, A B; Nissanke, S; Nitz, A; Noack, A; Nocera, F; Nolting, D; North, C; Nuttall, L K; Oberling, J; O'Dea, G D; Ogin, G H; Oh, J J; Oh, S H; Ohme, F; Okada, M A; Oliver, M; Oppermann, P; Oram, Richard J; O'Reilly, B; Ormiston, R; Ortega, L F; O'Shaughnessy, R; Ossokine, S; Ottaway, D J; Overmier, H; Owen, B J; Pace, A E; Page, J; Page, M A; Pai, A; Pai, S A; Palamos, J R; Palashov, O; Palomba, C; Pal-Singh, A; Pan, Howard; Pan, Huang-Wei; Pang, B; Pang, P T H; Pankow, C; Pannarale, F; Pant, B C; Paoletti, F; Paoli, A; Papa, M A; Parida, A; Parker, W; Pascucci, D; Pasqualetti, A; Passaquieti, R; Passuello, D; Patil, M; Patricelli, B; Pearlstone, B L; Pedraza, M; Pedurand, R; Pekowsky, L; Pele, A; Penn, S; Perez, C J; Perreca, A; Perri, L M; Pfeiffer, H P; Phelps, M; Piccinni, O J; Pichot, M; Piergiovanni, F; Pierro, V; Pillant, G; Pinard, L; Pinto, I M; Pirello, M; Pitkin, M; Poe, M; Poggiani, R; Popolizio, P; Porter, E K; Post, A; Powell, J; Prasad, J; Pratt, J W W; Pratten, G; Predoi, V; Prestegard, T; Prijatelj, M; Principe, M; Privitera, S; Prodi, G A; Prokhorov, L G; Puncken, O; Punturo, M; Puppo, P; Pürrer, M; Qi, H; Quetschke, V; Quintero, E A; Quitzow-James, R; Raab, F J; Rabeling, D S; Radkins, H; Raffai, P; Raja, S; Rajan, C; Rajbhandari, B; Rakhmanov, M; Ramirez, K E; Ramos-Buades, A; Rapagnani, P; Raymond, V; Razzano, M; Read, J; Regimbau, T; Rei, L; Reid, S; Reitze, D H; Ren, W; Reyes, S D; Ricci, F; Ricker, P M; Rieger, S; Riles, K; Rizzo, M; Robertson, N A; Robie, R; Robinet, F; Rocchi, A; Rolland, L; Rollins, J G; Roma, V J; Romano, J D; Romano, R; Romel, C L; Romie, J H; Rosińska, D; Ross, M P; Rowan, S; Rüdiger, A; Ruggi, P; Rutins, G; Ryan, K; Sachdev, S; Sadecki, T; Sadeghian, L; Sakellariadou, M; Salconi, L; Saleem, M; Salemi, F; Samajdar, A; Sammut, L; Sampson, L M; Sanchez, E J; Sanchez, L E; Sanchis-Gual, N; Sandberg, V; Sanders, J R; Sassolas, B; Sathyaprakash, B S; Saulson, P R; Sauter, O; Savage, R L; Sawadsky, A; Schale, P; Scheel, M; Scheuer, J; Schmidt, J; Schmidt, P; Schnabel, R; Schofield, R M S; Schönbeck, A; Schreiber, E; Schuette, D; Schulte, B W; Schutz, B F; Schwalbe, S G; Scott, J; Scott, S M; Seidel, E; Sellers, D; Sengupta, A S; Sentenac, D; Sequino, V; Sergeev, A; Shaddock, D A; Shaffer, T J; Shah, A A; Shahriar, M S; Shaner, M B; Shao, L; Shapiro, B; Shawhan, P; Sheperd, A; Shoemaker, D H; Shoemaker, D M; Siellez, K; Siemens, X; Sieniawska, M; Sigg, D; Silva, A D; Singer, L P; Singh, A; Singhal, A; Sintes, A M; Slagmolen, B J J; Smith, B; Smith, J R; Smith, R J E; Somala, S; Son, E J; Sonnenberg, J A; Sorazu, B; Sorrentino, F; Souradeep, T; Spencer, A P; Srivastava, A K; Staats, K; Staley, A; Steinke, M; Steinlechner, J; Steinlechner, S; Steinmeyer, D; Stevenson, S P; Stone, R; Stops, D J; Strain, K A; Stratta, G; Strigin, S E; Strunk, A; Sturani, R; Stuver, A L; Summerscales, T Z; Sun, L; Sunil, S; Suresh, J; Sutton, P J; Swinkels, B L; Szczepańczyk, M J; Tacca, M; Tait, S C; Talbot, C; Talukder, D; Tanner, D B; Tápai, M; Taracchini, A; Tasson, J D; Taylor, J A; Taylor, R; Tewari, S V; Theeg, T; Thies, F; Thomas, E G; Thomas, M; Thomas, P; Thorne, K A; Thrane, E; Tiwari, S; Tiwari, V; Tokmakov, K V; Toland, K; Tonelli, M; Tornasi, Z; Torres-Forné, A; Torrie, C I; Töyrä, D; Travasso, F; Traylor, G; Trinastic, J; Tringali, M C; Trozzo, L; Tsang, K W; Tse, M; Tso, R; Tsukada, L; Tsuna, D; Tuyenbayev, D; Ueno, K; Ugolini, D; Unnikrishnan, C S; Urban, A L; Usman, S A; Vahlbruch, H; Vajente, G; Valdes, G; van Bakel, N; van Beuzekom, M; van den Brand, J F J; Van Den Broeck, C; Vander-Hyde, D C; van der Schaaf, L; van Heijningen, J V; van Veggel, A A; Vardaro, M; Varma, V; Vass, S; Vasúth, M; Vecchio, A; Vedovato, G; Veitch, J; Veitch, P J; Venkateswara, K; Venugopalan, G; Verkindt, D; Vetrano, F; Viceré, A; Viets, A D; Vinciguerra, S; Vine, D J; Vinet, J-Y; Vitale, S; Vo, T; Vocca, H; Vorvick, C; Vyatchanin, S P; Wade, A R; Wade, L E; Wade, M; Walet, R; Walker, M; Wallace, L; Walsh, S; Wang, G; Wang, H; Wang, J Z; Wang, W H; Wang, Y F; Ward, R L; Warner, J; Was, M; Watchi, J; Weaver, B; Wei, L-W; Weinert, M; Weinstein, A J; Weiss, R; Wen, L; Wessel, E K; Weßels, P; Westerweck, J; Westphal, T; Wette, K; Whelan, J T; Whiting, B F; Whittle, C; Wilken, D; Williams, D; Williams, R D; Williamson, A R; Willis, J L; Willke, B; Wimmer, M H; Winkler, W; Wipf, C C; Wittel, H; Woan, G; Woehler, J; Wofford, J; Wong, K W K; Worden, J; Wright, J L; Wu, D S; Wysocki, D M; Xiao, S; Yamamoto, H; Yancey, C C; Yang, L; Yap, M J; Yazback, M; Yu, Hang; Yu, Haocun; Yvert, M; Zadrożny, A; Zanolin, M; Zelenova, T; Zendri, J-P; Zevin, M; Zhang, L; Zhang, M; Zhang, T; Zhang, Y-H; Zhao, C; Zhou, M; Zhou, Z; Zhu, S J; Zhu, X J; Zucker, M E; Zweizig, J
2018-03-02
The LIGO Scientific and Virgo Collaborations have announced the event GW170817, the first detection of gravitational waves from the coalescence of two neutron stars. The merger rate of binary neutron stars estimated from this event suggests that distant, unresolvable binary neutron stars create a significant astrophysical stochastic gravitational-wave background. The binary neutron star component will add to the contribution from binary black holes, increasing the amplitude of the total astrophysical background relative to previous expectations. In the Advanced LIGO-Virgo frequency band most sensitive to stochastic backgrounds (near 25 Hz), we predict a total astrophysical background with amplitude Ω_{GW}(f=25 Hz)=1.8_{-1.3}^{+2.7}×10^{-9} with 90% confidence, compared with Ω_{GW}(f=25 Hz)=1.1_{-0.7}^{+1.2}×10^{-9} from binary black holes alone. Assuming the most probable rate for compact binary mergers, we find that the total background may be detectable with a signal-to-noise-ratio of 3 after 40 months of total observation time, based on the expected timeline for Advanced LIGO and Virgo to reach their design sensitivity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Tao; Hossain, Mahmud; Schepmoes, Athena A.
2012-08-03
Sandwich immunoassay is the standard technique used in clinical labs for quantifying protein biomarkers for disease detection, monitoring and therapeutic intervention. Albeit highly sensitive, the development of a specific immunoassay is rather time-consuming and associated with extremely high cost due to the requirement for paired immunoaffinity reagents of high specificity. Recently, mass spectrometry-based methods, specifically selected reaction monitoring mass spectrometry (SRM-MS), have been increasingly applied to measure low abundance biomarker candidates in tissue and biofluids, owing to high sensitivity and specificity, simplicity of assay configuration, and great multiplexing capability. In this study, we report for the first time the developmentmore » of immunoaffinity depletion-based workflows and SRM-MS assays that enable sensitive and accurate quantification of total and free prostate-specific antigen (PSA) in serum without the requirement for specific PSA antibodies. With stable isotope dilution and external calibration, low ng/mL level detection of both total and free PSA was consistently achieved in both PSA-spiked female serum samples and actual patient serum samples. Moreover, comparison of the results obtained when SRM PSA assays and conventional immunoassays were applied to the same samples showed very good correlation (R2 values ranging from 0.90 to 0.99) in several independent clinical serum sample sets, including a set of 33 samples assayed in a blinded test. These results demonstrate that the workflows and SRM assays developed here provide an attractive alternative for reliably measuring total and free PSA in human blood. Furthermore, simultaneous measurement of free and total PSA and many other biomarkers can be performed in a single analysis using high-resolution liquid chromatographic separation coupled with SRM-MS.« less
Characterization of a tin-loaded liquid scintillator for gamma spectroscopy and neutron detection
NASA Astrophysics Data System (ADS)
Wen, Xianfei; Harvey, Taylor; Weinmann-Smith, Robert; Walker, James; Noh, Young; Farley, Richard; Enqvist, Andreas
2018-07-01
A tin-loaded liquid scintillator has been developed for gamma spectroscopy and neutron detection. The scintillator was characterized in regard to energy resolution, pulse shape discrimination, neutron light output function, and timing resolution. The loading of tin into scintillators with low effective atomic number was demonstrated to provide photopeaks with acceptable energy resolution. The scintillator was shown to have reasonable neutron/gamma discrimination capability based on the charge comparison method. The effect on the discrimination quality of the total charge integration time and the initial delay time for tail charge integration was studied. To obtain the neutron light output function, the time-of-flight technique was utilized with a 252Cf source. The light output function was validated with the MCNPX-PoliMi code by comparing the measured and simulated pule height spectra. The timing resolution of the developed scintillator was also evaluated. The tin-loading was found to have negligible impact on the scintillation decay times. However, a relatively large degradation of timing resolution was observed due to the reduced light yield.
Naserpour Farivar, Taghi; Najafipour, Reza; Johari, Pouran; Aslanimehr, Masoumeh; Peymani, Amir; Jahani Hashemi, Hoasan; Mirzaui, Baman
2014-10-01
We developed and evaluated the utility of a quadruplex Taqman real-time PCR assay that allows simultaneous identification of vancomycin-resistant genotypes and clinically relevant enterococci. The specificity of the assay was tested using reference strains of vancomycin-resistant and susceptible enterococci. In total, 193 clinical isolates were identified and subsequently genotyped using a Quadruplex Taqman real-time PCR assay and melting curve analysis. Representative Quadruplex Taqman real-time PCR amplification curve were obtained for Enterococcus faecium, Enterococcus faecalis, vanA-containing E. faecium, vanB-containing E. faecalis. Phenotypic and genotypic analysis of the isolates gave same results for 82 enterococcal isolates, while in 5 isolates, they were inconsistent. We had three mixed strains, which were detected by the TaqMan real-time PCR assay and could not be identified correctly using phenotypic methods. Vancomycin resistant enterococci (VRE) genotyping and identification of clinically relevant enterococci were rapidly and correctly performed using TaqMan real-time multiplex real-time PCR assay.
Human visceral leishmaniasis: a picture from Italy.
Abdalmaula, Giuma Harun; Barbadoro, Pamela; Marigliano, Anna; Illuminati, Diego; Di Stanislao, Francesco; D'Errico, Marcello Mario; Prospero, Emilia
2013-12-01
The aim of our study was to describe the distribution of Visceral Leishmaniasis (VL) in Italy, focusing on HIV-infected patients, to estimate the burden of the disease and the public health actions that should be undertaken. A review of official notifications and hospitalization data has been performed. From 2006 to 2008, a total of 289 cases of VL were notified; the overall notification rate was 1.63/1,000,000 (95% CI 1.45-1.83). In total, 1192 VL-associated hospitalizations were detected, with a hospitalization rate of 6.71/1,000,000 (95% CI 6.34-7.10). For the age group "≤ 24 years", a statistically significant increase was detected (p<0.05). A total of 68.9% (n = 821) of hospitalizations were detected in HIV-positive patients. The geographic distribution of rates revealed a significant increase in the north-eastern area of the country. Our study confirms that the epidemiological pattern of VL is changing and that, in Italy, control measures and preventive strategies should be based on not only the official notification system but also hospital data. This would lead to the identification of areas of parasite spread and to the creation of awareness campaigns geared toward general practitioners in the affected areas. Easy case detection would allow for timely public health actions and strategies for the implementation of more effective interventions for reservoir control. Copyright © 2013 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.
Huang, Alex S; Belghith, Akram; Dastiridou, Anna; Chopra, Vikas; Zangwill, Linda M; Weinreb, Robert N
2017-06-01
The purpose was to create a three-dimensional (3-D) model of circumferential aqueous humor outflow (AHO) in a living human eye with an automated detection algorithm for Schlemm’s canal (SC) and first-order collector channels (CC) applied to spectral-domain optical coherence tomography (SD-OCT). Anterior segment SD-OCT scans from a subject were acquired circumferentially around the limbus. A Bayesian Ridge method was used to approximate the location of the SC on infrared confocal laser scanning ophthalmoscopic images with a cross multiplication tool developed to initiate SC/CC detection automated through a fuzzy hidden Markov Chain approach. Automatic segmentation of SC and initial CC’s was manually confirmed by two masked graders. Outflow pathways detected by the segmentation algorithm were reconstructed into a 3-D representation of AHO. Overall, only <1% of images (5114 total B-scans) were ungradable. Automatic segmentation algorithm performed well with SC detection 98.3% of the time and <0.1% false positive detection compared to expert grader consensus. CC was detected 84.2% of the time with 1.4% false positive detection. 3-D representation of AHO pathways demonstrated variably thicker and thinner SC with some clear CC roots. Circumferential (360 deg), automated, and validated AHO detection of angle structures in the living human eye with reconstruction was possible.
Detection of Bacterial Meningitis Pathogens by PCR-Mass Spectrometry in Cerebrospinal Fluid.
Jing-Zi, Piao; Zheng-Xin, He; Wei-Jun, Chen; Yong-Qiang, Jiang
2018-06-01
Acute bacterial meningitis remains a life-threatening infectious disease with considerable morbidity and mortality. DNA-based detection methods are an urgent requisite for meningitis-causing bacterial pathogens for the prevention of outbreaks and control of infections. We proposed a novel PCR-mass spectrometry (PCR-Mass) assay for the simultaneous detection of four meningitis-causing agents, Neisseria meningitidis, Streptococcus pneumoniae, Haemophilus influenzae, and Mycobacterium tuberculosis in the present study. A total of 138 cerebrospinal fluid (CSF) samples (including 56 CSF culture positive, 44 CSF culture negative, and 38 CSF control) were enrolled and analyzed by PCR/Mass. Results were compared to real-time PCR detection. These four targeting pathogens could be discriminated without cross-reaction by the accurate detection of the corresponding extension products with different masses. The limits of detection were 102 copies/reaction for S. pneumoniae, H. influenzae, and N. meningitidis and 103 for M. tuberculosis. The evaluation of the culture-positive CSF specimens from the meningitis patients provided an overall agreement rate of 85.7% with PCR-Mass and real-time PCR. The PCR-Mass was also able to detect the targeting pathogens from culture-negative CSF specimens from meningitis patients receiving early antibiotic treatment. PCR-Mass could be used for the molecular detection of bacterial meningitis and tuberculosis, especially when early antibiotic treatment has been administered to the suspected patients.
Goss, Richard L.
1987-01-01
As part of the statistical summaries, trend tests were conducted. Several small uptrends were detected for total nitrogen, total organic nitrogen, total ammonia nitrogen, total nitrite nitrogen, total nitrate nitrogen, total organic plus ammonia nitrogen, total nitrite plus nitrate nitrogen, and total phosphorus. Small downtrends were detected for biochemical oxygen demand and dissolved magnesium.
NASA Astrophysics Data System (ADS)
Martinenghi, E.; Di Sieno, L.; Contini, D.; Sanzaro, M.; Pifferi, A.; Dalla Mora, A.
2016-07-01
We present the design and preliminary characterization of the first detection module based on Silicon Photomultiplier (SiPM) tailored for single-photon timing applications. The aim of this work is to demonstrate, thanks to the design of a suitable module, the possibility to easily exploit SiPM in many applications as an interesting detector featuring large active area, similarly to photomultipliers tubes, but keeping the advantages of solid state detectors (high quantum efficiency, low cost, compactness, robustness, low bias voltage, and insensitiveness to magnetic field). The module integrates a cooled SiPM with a total photosensitive area of 1 mm2 together with the suitable avalanche signal read-out circuit, the signal conditioning, the biasing electronics, and a Peltier cooler driver for thermal stabilization. It is able to extract the single-photon timing information with resolution better than 100 ps full-width at half maximum. We verified the effective stabilization in response to external thermal perturbations, thus proving the complete insensitivity of the module to environment temperature variations, which represents a fundamental parameter to profitably use the instrument for real-field applications. We also characterized the single-photon timing resolution, the background noise due to both primary dark count generation and afterpulsing, the single-photon detection efficiency, and the instrument response function shape. The proposed module can become a reliable and cost-effective building block for time-correlated single-photon counting instruments in applications requiring high collection capability of isotropic light and detection efficiency (e.g., fluorescence decay measurements or time-domain diffuse optics systems).
NASA Technical Reports Server (NTRS)
Campbell, J. W. (Editor)
1981-01-01
The detection of anthropogenic disturbances in the Earth's ozone layer was studied. Two topics were addressed: (1) the level at which a trend in total ozoning is detected by existing data sources; and (2) empirical evidence in the prediction of the depletion in total ozone. Error sources are identified. The predictability of climatological series, whether empirical models can be trusted, and how errors in the Dobson total ozone data impact trend detectability, are discussed.
The Low Energy Neutrino Spectrometry (LENS) Experiment and LENS prototype, μLENS, initial results
NASA Astrophysics Data System (ADS)
Yokley, Zachary
2012-03-01
LENS is a low energy solar neutrino detector that will measure the solar neutrino spectrum above 115 keV, >95% of the solar neutrino flux, in real time. The fundamental neutrino reaction in LENS is charged-current based capture on 115-In detected in a liquid scintillator medium. The reaction yields the prompt emission of an electron and the delayed emission of 2 gamma rays that serve as a time & space coincidence tag. Sufficient spatial resolution is used to exploit this signature and suppress background, particularly due to 115-In beta decay. A novel design of optical segmentation (Scintillation Lattice or SL) channels the signal light along the three primary axes. The channeling is achieved via total internal reflection by suitable low index gaps in the segmentation. The spatial resolution of a nuclear event is obtained digitally, much more precisely than possible by common time of flight methods. Advanced Geant4 analysis methods have been developed to suppress adequately the severe background due to 115-In beta decay, achieving at the same time high detection efficiency. LENS physics and detection methods along with initial results characterizing light transport in the as built μLENS prototype will be presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Chien-Yi; Hill, Richard J.; Solon, Mikhail P.
WIMP-nucleon scattering is analyzed at ordermore » $1/M$ in Heavy WIMP Effective Theory. The $1/M$ power corrections, where $$M\\gg m_W$$ is the WIMP mass, distinguish between different underlying UV models with the same universal limit and their impact on direct detection rates can be enhanced relative to naive expectations due to generic amplitude-level cancellations at leading order. The necessary one- and two-loop matching calculations onto the low-energy effective theory for WIMP interactions with Standard Model quarks and gluons are performed for the case of an electroweak SU(2) triplet WIMP, considering both the cases of elementary fermions and composite scalars. The low-velocity WIMP-nucleon scattering cross section is evaluated and compared with current experimental limits and projected future sensitivities. Our results provide the most robust prediction for electroweak triplet Majorana fermion dark matter direct detection rates; for this case, a cancellation between two sources of power corrections yields a small total $1/M$ correction, and a total cross section close to the universal limit for $$M \\gtrsim {\\rm few} \\times 100\\,{\\rm GeV}$$. For the SU(2) composite scalar, the $1/M$ corrections introduce dependence on underlying strong dynamics. Using a leading chiral logarithm evaluation, the total $1/M$ correction has a larger magnitude and uncertainty than in the fermionic case, with a sign that further suppresses the total cross section. These examples provide definite targets for future direct detection experiments and motivate large scale detectors capable of probing to the neutrino floor in the TeV mass regime.« less
Wang, Hye-young; Kim, Sunghyun; Kim, Jungho; Park, Soon-Deok
2014-01-01
Methicillin-resistant Staphylococcus aureus (MRSA) is the most prevalent cause of bloodstream infections (BSIs) and is recognized as a major nosocomial pathogen. This study aimed to evaluate a newly designed multiplex real-time PCR assay capable of the simultaneous detection of mecA, S. aureus, and coagulase-negative staphylococci (CoNS) in blood culture specimens. The Real-MRSA and Real-MRCoNS multiplex real-time PCR assays (M&D, Republic of Korea) use the TaqMan probes 16S rRNA for Staphylococcus spp., the nuc gene for S. aureus, and the mecA gene for methicillin resistance. The detection limit of the multiplex real-time PCR assay was 103 CFU/ml per PCR for each gene target. The multiplex real-time PCR assay was evaluated using 118 clinical isolates from various specimen types and a total of 350 positive blood cultures from a continuous monitoring blood culture system. The results obtained with the multiplex real-time PCR assay for the three targets were in agreement with those of conventional identification and susceptibility testing methods except for one organism. Of 350 positive bottle cultures, the sensitivities of the multiplex real-time PCR kit were 100% (166/166 cultures), 97.2% (35/36 cultures), and 99.2% (117/118 cultures) for the 16S rRNA, nuc, and mecA genes, respectively, and the specificities for all three targets were 100%. The Real-MRSA and Real-MRCoNS multiplex real-time PCR assays are very useful for the rapid accurate diagnosis of staphylococcal BSIs. In addition, the Real-MRSA and Real-MRCoNS multiplex real-time PCR assays could have an important impact on the choice of appropriate antimicrobial therapy, based on detection of the mecA gene. PMID:24648566
Jo, J A; Fang, Q; Papaioannou, T; Qiao, J H; Fishbein, M C; Beseth, B; Dorafshar, A H; Reil, T; Baker, D; Freischlag, J; Shung, K K; Sun, L; Marcu, L
2006-01-01
In this study, time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) and ultrasonography were applied to detect vulnerable (high-risk) atherosclerotic plaque. A total of 813 TR-LIFS measurements were taken from carotid plaques of 65 patients, and subsequently analyzed using the Laguerre deconvolution technique. The investigated spots were classified by histopathology as thin, fibrotic, calcified, low-inflamed, inflamed and necrotic lesions. Spectral and time-resolved parameters (normalized intensity values and Laguerre expansion coefficients) were extracted from the TR-LIFS data. Feature selection for classification was performed by either analysis of variance (ANOVA) or principal component analysis (PCA). A stepwise linear discriminant analysis algorithm was developed for detecting inflamed and necrotic lesion, representing the most vulnerable plaques. These vulnerable plaques were detected with high sensitivity (>80%) and specificity (>90%). Ultrasound (US) imaging was obtained in 4 carotid plaques in addition to TR-LIFS examination. Preliminary results indicate that US provides important structural information of the plaques that could be combined with the compositional information obtained by TR-LIFS, to obtain a more accurate diagnosis of vulnerable atherosclerotic plaque.
Bergmann, Sven M; Riechardt, Meike; Fichtner, Dieter; Lee, Peiyu; Kempter, Jolanta
2010-02-01
Previous and new PCRs for KHV detection were compared by estimation of their sensitivity in recognizing KHV DNA in plasmids, cell culture extracted KHV DNA and total DNA obtained from field tissue samples. A modified real-time PCR (Gilad et al., 2004), combined with an internal control system (IC2, Hoffmann et al., 2006) in a duplex assay, was used as a "gold standard". The lowest reliably determined virus concentration between, 5 and 10 KHV DNA genomic equivalents, was found by real-time PCR (Gilad et al., 2004), nested PCR (Bergmann et al., 2006) and one-tube semi-nested PCR. All other published and unpublished PCRs, as well as the commercial Loopamp, recognized KHV DNA at higher concentrations only. Additionally, KHV variants, newly adapted to European conditions, which could not be detected by PCR according to Bercovier et al. (2005) were found in two field samples from carp and koi from different regions of Germany. A negative influence of sample pooling was shown with field samples tested by real-time PCR. 2009 Elsevier B.V. All rights reserved.
Flood flows, leaf breakdown, and plant-available nitrogen on a dryland river floodplain
Andersen, Douglas C.; Nelson, S. Mark; Binkley, Dan
2003-01-01
We tested the hypothesis that decomposition in flood-inundated patches of riparian tree leaf litter results in higher plant-available nitrogen in underlying, nutrient-poor alluvium. We used leafpacks (n = 56) containing cottonwood (Populus deltoides ssp. wislizenii) leaf litter to mimic natural accumulations of leaves in an experiment conducted on the Yampa River floodplain in semi-arid northwestern Colorado, USA. One-half of the leafpacks were set on the sandy alluvial surface, and one-half were buried 5 cm below the surface. The presence of NO3− and NH4+ presumed to result from a leafpack's submergence during the predictable spring flood pulse was assessed using an ion-exchange resin bag (IER) placed beneath each leafpack and at control locations. Leafpacks and IERs were collected one week after flood peak (71 days total exposure) at half the stations; the remainder were collected three weeks later (93 days exposure). A multi-peaked spring flood with above-average maximum discharge inundated leafpacks for total time periods ranging from 133 to 577 hours. Litter lost from 43 to 68 percent of its initial organic matter (OM) content. Organic matter loss increased with total time inundated and total time of exposure on the floodplain. Burial retarded OM loss if the total time inundated was relatively long, and substrate texture (sand vs. silt) affected OM loss in a complex manner through interactions with total time inundated and total time of exposure. No pulse of N attributable to leaf breakdown was detected in the IERs, and leafpack litter showed no net change in the mass of nitrogen present. Patterns of leafpack and IER nitrogen levels suggested that litter removed N from floodwater and thereby reduced N availability in underlying sediment. Immobilization of floodwater-N by litter and N mineralization outside the flood period may be important components of N flux in semi-arid and arid floodplain environments.
Gordon, Sarah M; Elegino-Steffens, Diane U; Agee, Willie; Barnhill, Jason; Hsue, Gunther
2013-01-01
Upper respiratory tract infections (URIs) can be a serious burden to the healthcare system. The majority of URIs are viral in etiology, but definitive diagnosis can prove difficult due to frequently overlapping clinical presentations of viral and bacterial infections, and the variable sensitivity, and lengthy turn-around time of viral culture. We tested new automated nested multiplex PCR technology, the FilmArray® system, in the TAMC department of clinical investigations, to determine the feasibility of replacing the standard viral culture with a rapid turn-around system. We conducted a feasibility study using a single-blinded comparison study, comparing PCR results with archived viral culture results from a convenience sample of cryopreserved archived nasopharyngeal swabs from acutely ill ED patients who presented with complaints of URI symptoms. A total of 61 archived samples were processed. Viral culture had previously identified 31 positive specimens from these samples. The automated nested multiplex PCR detected 38 positive samples. In total, PCR was 94.5% concordant with the previously positive viral culture results. However, PCR was only 63.4% concordant with the negative viral culture results, owing to PCR detection of 11 additional viral pathogens not recovered on viral culture. The average time to process a sample was 75 minutes. We determined that an automated nested multiplex PCR is a feasible alternative to viral culture in an acute clinical setting. We were able to detect at least 94.5% as many viral pathogens as viral culture is able to identify, with a faster turn-around time. PMID:24052914
Song, Chao; Zhang, Cong; Fan, Limin; Qiu, Liping; Wu, Wei; Meng, Shunlong; Hu, Gengdong; Kamira, Barry; Chen, Jiazhang
2016-10-01
Antibiotics are widely used to improve the health and yields of farmed animals, including fish, but their use is accompanied by undesirable ecological effects. Relatively little is known about the water-body burden of antibiotics and their influence on primary productivity in aquaculture ecosystem. In this study, antibiotics usage within 24 fishponds, covering 4 areas, sampled 5 times, and having 5 fish species, was investigated surrounding Tai Lake in China. The study analyzed 15 antibiotics (including 5 sulfonamides, 2 quinolones, 3 β-lactams, 3 tetracyclines, 1 amphenicol, and 1 macrolide), and all of them were detected in water samples, with a detection frequency of 2-60%. Sulfonamides were the most prevalent, and concentrations of sulfamethoxazole, sulfamonomethoxine, and florfenicol being over 2000 ng L(-1) in some samples, while the other antibiotics levels ranged from ND (no detection) to 551.18 ng L(-1). Significant differences were observed in antibiotic burden among different regions for total antibiotics, sulfonamides, quinolones, and amphenicols; among time points for quinolones, β-lactams, and tetracyclines; and among species for quinolones and macrolides. Furthermore, basing on the risk quotient (RQ) method, the assessment revealed that florfenicol was of highest risk to algae with RQ values exceeding 0.1, while macrolide erythromycin posed the second highest risk. The partial correlation coefficient between total antibiotics and chlorophyll (a) was -0.035 that clearly indicated total antibiotics were detrimental to green algae growth, while the nutrient input and other physical - chemical factors were much more beneficial. Overall, holistic far-reaching measures of antibiotics control are recommended to preserve aquaculture ecosystem health. Copyright © 2016 Elsevier Ltd. All rights reserved.
Arer, Ilker Murat; Kus, Murat; Akkapulu, Nezih; Aytac, Huseyin Ozgur; Yabanoglu, Hakan; Caliskan, Kenan; Tarim, Mehmet Akin
2017-02-01
Postoperative hypocalcemia is the most common complication after total thyroidectomy. Postoperative parathyroid hormone (PTH) measurement is one of the methods to detect or prevent postoperative hypocalcemia. Prophylactic oral calcium supplementation is another method to prevent early postoperative hypocalcemia. The aim of this study is to detect the accurate timing of PTH and evaluate efficacy of routine oral calcium supplementation for postoperative hypocalcemia. A total of 106 patients were performed total thyroidectomy. Rotuine oral calcium supplementation was given to group 1 and no treatment to group 2 according to randomization. Serum calcium and PTH level of patients in group 2 at postoperative 6, 12 and 24 h and patients in both groups at postoperative day 7 were evaluated. Patients were compared according to age, sex, operation findings, serum calcium and PTH levels and symptomatic hypocalcemia. Half of the patients (50%) were in group 1. Most of the patients were female (83%). The most common etiology of thyroid disease was multinodular goiter (64.1%). Oral calcium supplementation was given to 18 (33.9%) patients in group 2. Symptomatic hypocalcemia for group 1 and 2 was found to be 1.9 and 33.9% respectively (p < 0.05). No statistical difference can be observed regarding the timing of serum biomarkers. Serum PTH levels at postoperative 12 and 24 h can predict early post-thyroidectomy hypocalcemia. Prophylactic oral calcium supplementation therapy can prevent early post-thyroidectomy hypocalcemia with advantages of being cost effective and safe. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
Laparoendoscopic Single-Site Sentinel Lymph Node Detection in Endometrial Cancer.
Demirayak, Gökhan; Comba, Cihan; Özdemir, İsa Aykut
2017-11-13
To demonstrate the feasibility of sentinel lymph node (SLN) biopsy using a laparoendoscopic single-site (LESS) approach in endometrial cancer (EC). A step-by-step video demonstration of the surgical procedure (Canadian Task Force Classification III). The satisfaction of patients who undergo LESS hysterectomy is greater than that reported by patients who undergo multiport laparoscopic hysterectomy, owing to better cosmesis and reduced postoperative analgesic requirements [1]. SLN biopsy is associated with significantly lower estimated blood loss, shorter operation time, and less morbidity compared with systematic lymphadenectomy [2]. LESS surgery can be more feasible and safer with the use of SLN biopsy compared with complete lymphadenectomy in patients with early-stage EC. This 69-year-old woman with grade 2 endometrioid EC underwent SLN mapping followed by LESS SLN biopsy, total hysterectomy, and bilateral salpingo-oophorectomy. Before the umbilical incision was made, 1.25 mg/mL of indocyanine green was injected into the cervical stroma at the 3 o'clock and 9 o'clock positions to both deep and superficial levels. A 10-mm 30° standard-length optical camera for near-infrared fluorescence imaging was used. The total operative time was 75 minutes, and the estimated blood loss was 20 mL. SLNs were detected bilaterally between proximal parts of the external iliac arteries and veins. After SLN resection, total hysterectomy and bilateral salpingo-oophorectomy were performed. No postoperative complications occurred. The patient was discharged at 30 hours after surgery. In the final pathology, stage 1A G2 EC was detected. LESS SLN biopsy and TLH-BSO is a feasible procedure and sentinel lymph node concept may increase the use of LESS in EC. Copyright © 2017 American Association of Gynecologic Laparoscopists. Published by Elsevier Inc. All rights reserved.
Nicolaou, Nicoletta; Goodacre, Royston
2008-10-01
Microbiological safety plays a very significant part in the quality control of milk and dairy products worldwide. Current methods used in the detection and enumeration of spoilage bacteria in pasteurized milk in the dairy industry, although accurate and sensitive, are time-consuming. FT-IR spectroscopy is a metabolic fingerprinting technique that can potentially be used to deliver results with the same accuracy and sensitivity, within minutes after minimal sample preparation. We tested this hypothesis using attenuated total reflectance (ATR), and high throughput (HT) FT-IR techniques. Three main types of pasteurized milk - whole, semi-skimmed and skimmed - were used and milk was allowed to spoil naturally by incubation at 15 degrees C. Samples for FT-IR were obtained at frequent, fixed time intervals and pH and total viable counts were also recorded. Multivariate statistical methods, including principal components-discriminant function analysis and partial least squares regression (PLSR), were then used to investigate the relationship between metabolic fingerprints and the total viable counts. FT-IR ATR data for all milks showed reasonable results for bacterial loads above 10(5) cfu ml(-1). By contrast, FT-IR HT provided more accurate results for lower viable bacterial counts down to 10(3) cfu ml(-1) for whole milk and, 4 x 10(2) cfu ml(-1) for semi-skimmed and skimmed milk. Using FT-IR with PLSR we were able to acquire a metabolic fingerprint rapidly and quantify the microbial load of milk samples accurately, with very little sample preparation. We believe that metabolic fingerprinting using FT-IR has very good potential for future use in the dairy industry as a rapid method of detection and enumeration.
NASA Astrophysics Data System (ADS)
Ringhausen, J.
2017-12-01
This research combines satellite measurements of lightning in Hurricane Harvey with ground-based lightning measurements to get a better sense of the total lightning occurring in the hurricane, both intra-cloud (IC) and cloud-to-ground (CG), and how it relates to the intensification and weakening of the tropical system. Past studies have looked at lightning trends in hurricanes using the space based Lightning Imaging Sensor (LIS) or ground-based lightning detection networks. However, both of these methods have drawbacks. For instance, LIS was in low earth orbit, which limited lightning observations to 90 seconds for a particular point on the ground; hence, continuous lightning coverage of a hurricane was not possible. Ground-based networks can have a decreased detection efficiency, particularly for ICs, over oceans where hurricanes generally intensify. With the launch of the Geostationary Lightning Mapper (GLM) on the GOES-16 satellite, researchers can study total lightning continuously over the lifetime of a tropical cyclone. This study utilizes GLM to investigate total lightning activity in Hurricane Harvey temporally; this is augmented with spatial analysis relative to hurricane structure, similar to previous studies. Further, GLM and ground-based network data are combined using Bayesian techniques in a new manner to leverage the strengths of each detection method. This methodology 1) provides a more complete estimate of lightning activity and 2) enables the derivation of the IC:CG ratio (Z-ratio) throughout the time period of the study. In particular, details of the evolution of the Z-ratio in time and space are presented. In addition, lightning stroke spatiotemporal trends are compared to lightning flash trends. This research represents a new application of lightning data that can be used in future study of tropical cyclone intensification and weakening.
Stelzer, Erin A.; Loftin, Keith A.; Struffolino, Pamela
2013-01-01
Water samples were collected from Maumee Bay State Park Lakeside Beach, Oregon, Ohio, during the 2012 recreational season and analyzed for selected cyanobacteria gene sequences by DNA-based quantitative polymerase chain reaction (qPCR) and RNA-based quantitative reverse-transcription polymerase chain reaction (qRT-PCR). Results from the four DNA assays (for quantifying total cyanobacteria, total Microcystis, and Microcystis and Planktothrix strains that possess the microcystin synthetase E (mcyE) gene) and two RNA assays (for quantifying Microcystis and Planktothrix genera that are expressing the microcystin synthetase E (mcyE) gene) were compared to microcystin concentration results determined by an enzyme-linked immunosorbent assay (ELISA). Concentrations of the target in replicate analyses were log10 transformed. The average value of differences in log10 concentrations for the replicates that had at least one detection were found to range from 0.05 to >0.37 copy per 100 milliliters (copy/100 mL) for DNA-based methods and from >0.04 to >0.17 copy/100 mL for RNA-based methods. RNA has a shorter half-life than DNA; consequently, a 24-hour holding-time study was done to determine the effects of holding time on RNA concentrations. Holding-time comparisons for the RNA-based Microcystis toxin mcyE assay showed reductions in the number of copies per 100 milliliters over 24 hours. The log difference between time 2 hours and time 24 hours was >0.37 copy/100 mL, which was higher than the analytical variability (log difference of >0.17 copy/100 mL). Spearman’s correlation analysis indicated that microcystin toxin concentrations were moderately to highly related to DNA-based assay results for total cyanobacteria (rho=0.69), total Microcystis (rho=0.74), and Microcystis strains that possess the mcyE gene (rho=0.81). Microcystin toxin concentrations were strongly related with RNA-based assay results for Microcystis mcyE gene expression (rho=0.95). Correlation analysis could not be done for Planktothrix mcyE gene expression because of too few detections.
Low-dose electron energy-loss spectroscopy using electron counting direct detectors.
Maigné, Alan; Wolf, Matthias
2018-03-01
Since the development of parallel electron energy loss spectroscopy (EELS), charge-coupled devices (CCDs) have been the default detectors for EELS. With the recent development of electron-counting direct-detection cameras, micrographs can be acquired under very low electron doses at significantly improved signal-to-noise ratio. In spectroscopy, in particular in combination with a monochromator, the signal can be extremely weak and the detection limit is principally defined by noise introduced by the detector. Here we report the use of an electron-counting direct-detection camera for EEL spectroscopy. We studied the oxygen K edge of amorphous ice and obtained a signal noise ratio up to 10 times higher than with a conventional CCD.We report the application of electron counting to record time-resolved EEL spectra of a biological protein embedded in amorphous ice, revealing chemical changes observed in situ while exposed by the electron beam. A change in the fine structure of nitrogen K and the carbon K edges were recorded during irradiation. A concentration of 3 at% nitrogen was detected with a total electron dose of only 1.7 e-/Å2, extending the boundaries of EELS signal detection at low electron doses.
Ohnishi, Shunsuke; Vanderheyden, Jean-Luc; Tanaka, Eiichi; Patel, Bhavesh; De Grand, Alec; Laurence, Rita G.; Yamashita, Kenichiro; Frangioni, John V.
2008-01-01
The intraoperative detection of cell injury and cell death is fundamental to human surgeries such as organ transplantation and resection. Because of low autofluorescence background and relatively high tissue penetration, invisible light in the 800 nm region provides sensitive detection of disease pathology without changing the appearance of the surgical field. In order to provide surgeons with real-time intraoperative detection of cell injury and death after ischemia/reperfusion (I/R), we have developed a bioactive derivative of human annexin V (annexin800), which fluoresces at 800 nm. Total fluorescence yield, as a function of bioactivity, was optimized in vitro, and final performance was assessed in vivo. In liver, intestine and heart animal models of I/R, an optimal signal to background ratio was obtained 30 min after intravenous injection of annexin800, and histology confirmed concordance between planar reflectance images and actual deep tissue injury. In summary, annexin800 permits sensitive, real-time detection of cell injury and cell death after I/R in the intraoperative setting, and can be used during a variety of surgeries for rapid assessment of tissue and organ status. PMID:16869796
NASA Astrophysics Data System (ADS)
Zhang, Fangfang; Ma, Junjie; Watanabe, Junji; Tang, Jinlong; Liu, Huiyu; Shen, Heyun
2017-02-01
An electrophoretic technique was combined with an enzyme-linked immunosorbent assay (ELISA) system to achieve a rapid and sensitive immunoassay. A cellulose acetate filter modified with polyelectrolyte multilayer (PEM) was used as a solid substrate for three-dimensional antigen-antibody reactions. A dual electrophoresis process was used to induce directional migration and local condensation of antigens and antibodies at the solid substrate, avoiding the long diffusion times associated with antigen-antibody reactions in conventional ELISAs. The electrophoretic forces drove two steps in the ELISA process, namely the adsorption of antigen, and secondary antibody-labelled polystyrene nanoparticles (NP-Ab). The total time needed for dual electrophoresis-driven detection was just 4 min, nearly 2 h faster than a conventional ELISA system. Moreover, the rapid NP-Ab electrophoresis system simultaneously achieved amplification of the specific signal and a reduction in noise, leading to a more sensitive NP-Ab immunoassay with a limit of detection (LOD) of 130 fM, and wide range of detectable concentrations from 0.13 to 130 pM. These results suggest that the combination of dual electrophoresis detection and NP-Ab signal amplification has great potential for future immunoassay systems.
Polyion selective polymeric membrane-based pulstrode as a detector in flow-injection analysis.
Bell-Vlasov, Andrea K; Zajda, Joanna; Eldourghamy, Ayman; Malinowska, Elzbieta; Meyerhoff, Mark E
2014-04-15
A method for the detection of polyions using fully reversible polyion selective polymeric membrane type pulstrodes as detectors in a flow-injection analysis (FIA) system is examined. The detection electrode consists of a plasticized polymeric membrane doped with 10 wt % of tridodecylmethylammonium-dinonylnaphthalene sulfonate (TDMA/DNNS) ion-exchanger salt. The pulse sequence used involves a short (1 s) galvanostatic pulse, an open-circuit pulse (0.5 s) during which the EMF of the cell is measured, and a longer (15 s) potentiostatic pulse to return the membrane to its original chemical composition. It is shown that total pulse sequence times can be optimized to yield reproducible real-time detection of injected samples of protamine and heparin at up to 20 samples/h. Further, it is shown that the same membrane detector can be employed for FIA detection of both polycations at levels ≥10 μg/mL and polyanions at levels of ≥40 μg/mL by changing the direction of the galvanostatic pulse. The methodology described may also be applicable in the detection of polyionic species at low levels in other flowing configurations, such as in liquid chromatography and capillary electrophoresis.
Markwalter, Christine F.; Gibson, Lauren E.; Mudenda, Lwiindi; Kimmel, Danielle W.; Mbambara, Saidon; Thuma, Philip E.; Wright, David W.
2018-01-01
Abstract. A rapid, on-bead enzyme-linked immunosorbent assay for Plasmodium lactate dehydrogenase (pLDH) and Plasmodium falciparum histidine-rich protein 2 (HRP2) was adapted for use with dried blood spot (DBS) samples. This assay detected both biomarkers from a single DBS sample with only 45 minutes of total incubation time and detection limits of 600 ± 500 pM (pLDH) and 69 ± 30 pM (HRP2), corresponding to 150 and 24 parasites/μL, respectively. This sensitive and reproducible on-bead detection method was used to quantify pLDH and HRP2 in patient DBS samples from rural Zambia collected at multiple time points after treatment. Biomarker clearance patterns relative to parasite clearance were determined; pLDH clearance followed closely with parasite clearance, whereas most patients maintained detectable levels of HRP2 for 35–52 days after treatment. Furthermore, weak-to-moderate correlations between biomarker concentration and parasite densities were found for both biomarkers. This work demonstrates the utility of the developed assay for epidemiological study and surveillance of malaria. PMID:29557342
A Contactless Capacitance Detection System for Microchip Capillary Electrophoresis
NASA Astrophysics Data System (ADS)
Wu, Peter
2008-05-01
The design, construction and operation of a simple, inexpensive and compact high voltage power supply for use in conjunction with a simple cross, capillary electrophoresis microchip is presented. The detection system utilizes a single high voltage power supply (15 kV), a voltage divider network for obtaining the required voltages for enabling a gated injection valve, and two high voltage relays for switching between the open and closed gate sequences of the injection. The system is used to determine sodium monofluoroacetate (MFA) concentration in diluted fruit juices and tap water. A separation buffer consisting of 20 mM citric acid and histidine at pH 3.5 enabled the detection of the anion in diluted apple juice, cranberry juice, and orange juice without lengthy sample pretreatments. Limit of detection in diluted juices and tap water were determined to be 125, 167, 138, and 173 mg/L for tap water, apple juice, cranberry juice, and orange juice, respectively, based upon an S/N of 3:1. The total analysis time for detecting the MFA anion in fruit juices was less than 5 min, which represents a considerable reduction in analysis time compared to other analytical methods currently used in food analysis.
Cottenet, Geoffrey; Blancpain, Carine; Sonnard, Véronique; Chuah, Poh Fong
2013-08-01
Considering the increase of the total cultivated land area dedicated to genetically modified organisms (GMO), the consumers' perception toward GMO and the need to comply with various local GMO legislations, efficient and accurate analytical methods are needed for their detection and identification. Considered as the gold standard for GMO analysis, the real-time polymerase chain reaction (RTi-PCR) technology was optimised to produce a high-throughput GMO screening method. Based on simultaneous 24 multiplex RTi-PCR running on a ready-to-use 384-well plate, this new procedure allows the detection and identification of 47 targets on seven samples in duplicate. To comply with GMO analytical quality requirements, a negative and a positive control were analysed in parallel. In addition, an internal positive control was also included in each reaction well for the detection of potential PCR inhibition. Tested on non-GM materials, on different GM events and on proficiency test samples, the method offered high specificity and sensitivity with an absolute limit of detection between 1 and 16 copies depending on the target. Easy to use, fast and cost efficient, this multiplex approach fits the purpose of GMO testing laboratories.
2015-06-01
The weekly Navigators Bible study group, a rotating cast totaling about 120 men led by Bob Reehm, was a crucial ensemble in this effort. Their...grace, that we may receive mercy and find grace to help in time of need. Hebrews 4:15-16 For the Lord gives wisdom; from his mouth come knowledge
Crain, Angela S.
2006-01-01
Water samples were collected in streams and springs in the karst terrane of the Sinking Creek Basin in 2004 as part of study in cooperation with the Kentucky Department of Agriculture. A total of 48 water samples were collected at 7 sites (4 springs, 2 streams, and 1 karst window) from April through November 2004. The karst terrane of the Sinking Creek Basin (also known as Boiling Spring Basin) encompasses about 125 square miles in Breckinridge County and portions of Meade and Hardin Counties in Kentucky. Fourteen pesticides were detected of the 52 pesticides analyzed in the stream and spring samples. Of the 14 detected pesticides, 12 were herbicides and 2 were insecticides. The most commonly detected pesticides?atrazine, simazine, metolachlor, and acetochlor?were those most heavily used on crops during the study. Atrazine was detected in 100 percent of all samples; simazine, metolachlor, and acetochlor were detected in more than 35 percent of all samples. The pesticide-transformation compound, deethylatrazine, was detected in 98 percent of the samples. Only one nonagricultural herbicide, prometon, was detected in more than 30 percent of the samples. Malathion, the most commonly detected insecticide, was found in 4 percent of the samples, which was followed by carbofuran (2 percent). Most of the pesticides were present in low concentrations; however, atrazine was found in springs exceeding the U.S. Environmental Protection Agency?s (USEPA) standards for drinking water. Atrazine exceeded the USEPA?s maximum contaminant level 2 times in 48 detections. Concentrations of nitrate greater than 10 milligrams per liter (mg/L) were not found in water samples from any of the sites. Concentrations of nitrite plus nitrate ranged from 0.21 to 3.9 mg/L at the seven sites. The median concentration of nitrite plus nitrate for all sites sampled was 1.5 mg/L. Concentrations of nitrite plus nitrate generally were higher in the springs than in the main stem of Sinking Creek. Forty-two percent of the concentrations of total phosphorus at all seven sites exceeded the USEPA?s recommended maximum concentration of 0.1 mg/L. The median concentration of total phosphorus for all sites sampled was 0.09 mg/L. The highest median concentrations of total phosphorus were found in the springs. Median concentrations of orthophosphate followed the same pattern as concentrations of total phosphorus in the springs. Concentrations of orthophosphate ranged from <0.006 to 0.192 mg/L. Concentrations of suspended sediment generally were low throughout the basin; the median concentration of suspended sediment for all sites sampled was 23 mg/L. The highest concentration of suspended sediment (1,486 mg/L) was measured following a storm event at Sinking Creek near Lodiburg, Ky.
Flood Extent Mapping for Namibia Using Change Detection and Thresholding with SAR
NASA Technical Reports Server (NTRS)
Long, Stephanie; Fatoyinbo, Temilola E.; Policelli, Frederick
2014-01-01
A new method for flood detection change detection and thresholding (CDAT) was used with synthetic aperture radar (SAR) imagery to delineate the extent of flooding for the Chobe floodplain in the Caprivi region of Namibia. This region experiences annual seasonal flooding and has seen a recent renewal of severe flooding after a long dry period in the 1990s. Flooding in this area has caused loss of life and livelihoods for the surrounding communities and has caught the attention of disaster relief agencies. There is a need for flood extent mapping techniques that can be used to process images quickly, providing near real-time flooding information to relief agencies. ENVISAT/ASAR and Radarsat-2 images were acquired for several flooding seasons from February 2008 to March 2013. The CDAT method was used to determine flooding from these images and includes the use of image subtraction, decision based classification with threshold values, and segmentation of SAR images. The total extent of flooding determined for 2009, 2011 and 2012 was about 542 km2, 720 km2, and 673 km2 respectively. Pixels determined to be flooded in vegetation were typically <0.5 % of the entire scene, with the exception of 2009 where the detection of flooding in vegetation was much greater (almost one third of the total flooded area). The time to maximum flooding for the 2013 flood season was determined to be about 27 days. Landsat water classification was used to compare the results from the new CDAT with SAR method; the results show good spatial agreement with Landsat scenes.
Hill, S L; Grieger, D M; Olson, K C; Jaeger, J R; Dahlen, C R; Crosswhite, M R; Pereira, N Negrin; Underdahl, S R; Neville, B W; Ahola, J; Fischer, M C; Seidel, G E; Stevenson, J S
2016-09-01
We hypothesized that GnRH would increase pregnancy risk (PR) in a split-time AI program for cows in which estrus was not detected. A total of 1,236 suckled beef cows at 12 locations in 3 states (Colorado, Kansas, and North Dakota) were enrolled. Before applying the fixed-time AI program, BCS was assessed. Cows were treated on d -7 with a progesterone insert concurrent with 100 μg GnRH and on d 0 with 25 mg PGF plus removal of the insert. Estrus-detection patches were affixed to cows at insert removal. Estrus was defined to have occurred when an estrus-detection patch was >50% colored (activated). Cows in estrus by 65 h ( = 758; 61.3% of all cows) were randomly allocated to 2 treatments: 1) 100 μg GnRH and early + GnRH (E+G; = 373) or 2) AI only at 65 h (early - no GnRH [E-G]; = 385). The remaining cows were randomly allocated to 2 treatments: 1) 5(L+G; = 252) or 2) AI only at 84 h (late no GnRH [L-G]; = 226). Pregnancy was determined 35 d after AI via transrectal ultrasound. Pregnancy risk did not differ ( = 0.68) between E+G and E-G cows (61.9 vs. 60.4%, respectively). Conversely, for cows inseminated at 84 h, PR was greater ( = 0.01) in cows that received GnRH (L+G) compared with their herd mates not receiving GnRH (L- G; 41.7 vs. 30.8%, respectively). Of those cows not detected in estrus by 65 h, 42.1% were detected by 84 h, for a total expression of estrus by all cows of 77.6%. Administration of GnRH increased ( < 0.01) PR in cows not detected in estrus by 84 h (+GnRH = 33.4% [ = 146] vs. no GnRH = 15.0% [ = 128]) but had no effect in cows expressing estrus by 84 h (+GnRH = 65.3% [ = 103] vs. no GnRH = 61.7% [ = 97]). Neither estrus expression by 65 or 84 h nor PR was influenced by BCS, parity, or days postpartum at AI. Cows had greater PR when they had been detected in estrus before AI, and PR was improved by administration of GnRH at 65 h after insert removal in cows that were not detected in estrus and inseminated at 84 h.
NASA Astrophysics Data System (ADS)
Husemann, B.; Davis, T. A.; Jahnke, K.; Dannerbauer, H.; Urrutia, T.; Hodge, J.
2017-09-01
We present single-dish 12CO(1-0) and 12CO(2-1) observations for 14 low-redshift quasi-stellar objects (QSOs). In combination with optical integral field spectroscopy, we study how the cold gas content relates to the star formation rate (SFR) and black hole accretion rate. 12CO(1-0) is detected in 8 of 14 targets and 12CO(2-1) is detected in 7 out of 11 cases. The majority of disc-dominated QSOs reveal gas fractions and depletion times matching normal star-forming systems. Two gas-rich major mergers show clear starburst signatures with higher than average gas fractions and shorter depletion times. Bulge-dominated QSO hosts are mainly undetected in 12CO(1-0), which corresponds, on average, to lower gas fractions than in disc-dominated counterparts. Their SFRs, however, imply shorter than average depletion times and higher star formation efficiencies. Negative QSO feedback through removal of cold gas seems to play a negligible role in our sample. We find a trend between black hole accretion rate and total molecular gas content for disc-dominated QSOs when combined with literature samples. We interpret this as an upper envelope for the nuclear activity and it is well represented by a scaling relation between the total and circumnuclear gas reservoir accessible for accretion. Bulge-dominated QSOs significantly differ from that scaling relation and appear uncorrelated with the total molecular gas content. This could be explained either by a more compact gas reservoir, blown out of the gas envelope through outflows, or a different interstellar medium phase composition.
Xiang, Hongjun; Zhang, Lishi; Song, Jiannan; Fan, Bin; Nie, Yinglan; Bai, Dong; Lei, Haimin
2016-09-12
Guizhi decoction (GZD), a well-known traditional Chinese medicine (TCM) prescription consisting of Ramulus Cinnamomi, Radix Paeoniae Alba, Radix Glycyrrhizae, Fructus Jujubae and Rhizoma Zingiberis Recens, is usually used for the treatment of common colds, influenza, and other pyretic conditions in the clinic. However, the absorbed ingredients and metabolic compounds of GZD have not been reported. In this paper, a method incorporating rapid resolution liquid chromatography (RRLC) with quadrupole-time-of-flight mass spectrometry (Q-TOF-MS) was used to identify ingredients after oral administration of GZD. Identification of the primary components in GZD, drug-containing serum and urine samples was carried out in order to investigate the assimilation and metabolites of the decoction in vivo. By comparing the total ion chromatograms (TICs) of GZD, a total of 71 constituents were detected or characterized. By comparing TICs of blank and dosed rat plasma, a total of 15 constituents were detected and identified as prototypes according to their retention time (tR) and MS, MS/MS data. Based on this, neutral loss scans of 80 and 176 Da in samples of rat plasma and urine helped us to identify most of the metabolites. Results showed that the predominant metabolic pathways of (epi) catechin and gallic acid were sulfation, methylation, glucuronidation and dehydroxylation; the major metabolic pathways of flavone were hydrolysis, sulfation and glucuronidation. Furthermore, degradation, oxidation and ring fission were found to often occur in the metabolism process of GZD in vivo.
Xiang, Hongjun; Zhang, Lishi; Song, Jiannan; Fan, Bin; Nie, Yinglan; Bai, Dong; Lei, Haimin
2016-01-01
Guizhi decoction (GZD), a well-known traditional Chinese medicine (TCM) prescription consisting of Ramulus Cinnamomi, Radix Paeoniae Alba, Radix Glycyrrhizae, Fructus Jujubae and Rhizoma Zingiberis Recens, is usually used for the treatment of common colds, influenza, and other pyretic conditions in the clinic. However, the absorbed ingredients and metabolic compounds of GZD have not been reported. In this paper, a method incorporating rapid resolution liquid chromatography (RRLC) with quadrupole-time-of-flight mass spectrometry (Q-TOF-MS) was used to identify ingredients after oral administration of GZD. Identification of the primary components in GZD, drug-containing serum and urine samples was carried out in order to investigate the assimilation and metabolites of the decoction in vivo. By comparing the total ion chromatograms (TICs) of GZD, a total of 71 constituents were detected or characterized. By comparing TICs of blank and dosed rat plasma, a total of 15 constituents were detected and identified as prototypes according to their retention time (tR) and MS, MS/MS data. Based on this, neutral loss scans of 80 and 176 Da in samples of rat plasma and urine helped us to identify most of the metabolites. Results showed that the predominant metabolic pathways of (epi) catechin and gallic acid were sulfation, methylation, glucuronidation and dehydroxylation; the major metabolic pathways of flavone were hydrolysis, sulfation and glucuronidation. Furthermore, degradation, oxidation and ring fission were found to often occur in the metabolism process of GZD in vivo. PMID:27626411
Jeffrey Yang, Y; Haught, Roy C; Goodrich, James A
2009-06-01
Accurate detection and identification of natural or intentional contamination events in a drinking water pipe is critical to drinking water supply security and health risk management. To use conventional water quality sensors for the purpose, we have explored a real-time event adaptive detection, identification and warning (READiw) methodology and examined it using pilot-scale pipe flow experiments of 11 chemical and biological contaminants each at three concentration levels. The tested contaminants include pesticide and herbicides (aldicarb, glyphosate and dicamba), alkaloids (nicotine and colchicine), E. coli in terrific broth, biological growth media (nutrient broth, terrific broth, tryptic soy broth), and inorganic chemical compounds (mercuric chloride and potassium ferricyanide). First, through adaptive transformation of the sensor outputs, contaminant signals were enhanced and background noise was reduced in time-series plots leading to detection and identification of all simulated contamination events. The improved sensor detection threshold was 0.1% of the background for pH and oxidation-reduction potential (ORP), 0.9% for free chlorine, 1.6% for total chlorine, and 0.9% for chloride. Second, the relative changes calculated from adaptively transformed residual chlorine measurements were quantitatively related to contaminant-chlorine reactivity in drinking water. We have shown that based on these kinetic and chemical differences, the tested contaminants were distinguishable in forensic discrimination diagrams made of adaptively transformed sensor measurements.
Luo, Yaguang; Zhou, Bin; Van Haute, Sam; Nou, Xiangwu; Zhang, Boce; Teng, Zi; Turner, Ellen R; Wang, Qin; Millner, Patricia D
2018-04-01
Determining the minimal effective free chlorine (FC) concentration for preventing pathogen survival and cross-contamination during produce washing is critical for developing science- and risk-based food safety practices. The correlation between dynamic FC concentrations and bacterial survival was investigated during commercial washing of chopped Romaine lettuce, shredded Iceberg lettuce, and diced cabbage as pathogen inoculation study during commercial operation is not feasible. Wash water was sampled every 30 min and assayed for organic loading, FC, and total aerobic mesophilic bacteria after chlorine neutralization. Water turbidity, chemical oxygen demand, and total dissolved solids increased significantly over time, with more rapid increases in diced cabbage water. Combined chlorine increased consistently while FC fluctuated in response to rates of chlorine dosing, product loading, and water replenishment. Total bacterial survival showed a strong correlation with real-time FC concentration. Under approximately 10 mg/L, increasing FC significantly reduced the frequency and population of surviving bacteria detected. Increasing FC further resulted in the reduction of the aerobic plate count to below the detection limit (50 CFU/100 mL), except for a few sporadic positive samples with low cell counts. This study confirms that maintaining at least 10 mg/L FC in wash water strongly reduced the likelihood of bacterial survival and thus potential cross contamination of washed produce. Published by Elsevier Ltd.
Attention dysfunction of postoperative patients with glioma.
Fang, Dazhao; Jiang, Jian; Sun, Xiaoyang; Wang, Weijie; Dong, Nan; Fu, Xianhua; Pang, Cong; Chen, Xingui; Ding, Lianshu
2014-10-15
Attention dysfunction has been observed among many kinds of nervous system diseases, including glioma. This study aimed to investigate the correlation between glioma localization, malignancy, postoperative recovery time and attention deficit. A total of 45 patients with glioma who underwent surgical resection and 18 healthy volunteers were enrolled. The attention network test, digital span test, color trail test II and Stroop test were used to detect the characteristics of attention deficit. Orientation network dysfunction was detected in the parietal lobe tumor group, and execution network deficit was detected in both the frontal and parietal lobe groups, while no significant difference was detected in the temporal lobe group compared to healthy controls. The high-grade glioma group (grade III-IV) exhibited more serious functional impairment than the low-grade group (grade I-II). No significant correlation was observed between postoperative recovery time and attention impairment. High-grade glioma patients suffer more severe attention impairment. In addition, the frontal and parietal lobe glioma patients suffer attention dysfunction in dissimilar manner. These findings will provide important guidance on the care of glioma patients after therapy.
Long-term follow up of gallbladder polyps.
Park, Jeong Youp; Hong, Sung Pil; Kim, Yoon Jae; Kim, Hong Jeoung; Kim, Hee Man; Cho, Jae Hee; Park, Seung Woo; Song, Si Young; Chung, Jae Bock; Bang, Seungmin
2009-02-01
The management of gallbladder polyps (GBP) is directly linked to the early diagnosis of gallbladder cancer (GBC). This study aimed to evaluate the malignant risk of GBP. In total, 1558 patients diagnosed with GBP were followed. Neoplastic polyps were defined as GBC and its premalignant lesions. The risk for malignancy was estimated with the cumulative detection rate of neoplastic polyps. Thirty-three cases (2.1%) were diagnosed with neoplastic polyps. The cumulative detection rates of neoplastic polyps were 1.7% at 1 year, 2.8% at 5 years, and 4% at 8 years after diagnosis. The size of GBP and the presence of gallstones were risk factors for neoplastic polyps. Polyps > or = 10 mm had a 24.2 times greater risk of malignancy than polyps < 10 mm. However, 15 of 33 neoplastic polyps (45.5%) were < 10 mm at the time of diagnosis of GBP. During follow up in 36 (3.5%) of 1027 cases, an increase in size was detected; of these, nine (25%) had neoplastic polyps. Even small polyps have a risk of malignancy, and careful long-term follow up of GBP will help detect and treat early GBC.
ALFABURST: a commensal search for fast radio bursts with Arecibo
NASA Astrophysics Data System (ADS)
Foster, Griffin; Karastergiou, Aris; Golpayegani, Golnoosh; Surnis, Mayuresh; Lorimer, Duncan R.; Chennamangalam, Jayanth; McLaughlin, Maura; Armour, Wes; Cobb, Jeff; MacMahon, David H. E.; Pei, Xin; Rajwade, Kaustubh; Siemion, Andrew P. V.; Werthimer, Dan; Williams, Chris J.
2018-03-01
ALFABURST has been searching for fast radio bursts (FRBs) commensally with other projects using the Arecibo L-band Feed Array receiver at the Arecibo Observatory since 2015 July. We describe the observing system and report on the non-detection of any FRBs from that time until 2017 August for a total observing time of 518 h. With current FRB rate models, along with measurements of telescope sensitivity and beam size, we estimate that this survey probed redshifts out to about 3.4 with an effective survey volume of around 600 000 Mpc3. Based on this, we would expect, at the 99 per cent confidence level, to see at most two FRBs. We discuss the implications of this non-detection in the context of results from other telescopes and the limitation of our search pipeline. During the survey, single pulses from 17 known pulsars were detected. We also report the discovery of a Galactic radio transient with a pulse width of 3 ms and dispersion measure of 281 pc cm-3, which was detected while the telescope was slewing between fields.
Li, Peng; Jia, Junwei; Bai, Lan; Pan, Aihu; Tang, Xueming
2013-07-01
Genetically modified carnation (Dianthus caryophyllus L.) Moonshade was approved for planting and commercialization in several countries from 2004. Developing methods for analyzing Moonshade is necessary for implementing genetically modified organism labeling regulations. In this study, the 5'-transgene integration sequence was isolated using thermal asymmetric interlaced (TAIL)-PCR. Based upon the 5'-transgene integration sequence, conventional and TaqMan real-time PCR assays were established. The relative limit of detection for the conventional PCR assay was 0.05 % for Moonshade using 100 ng total carnation genomic DNA, corresponding to approximately 79 copies of the carnation haploid genome, and the limits of detection and quantification of the TaqMan real-time PCR assay were estimated to be 51 and 254 copies of haploid carnation genomic DNA, respectively. These results are useful for identifying and quantifying Moonshade and its derivatives.
NASA Astrophysics Data System (ADS)
Li, Xue; Hou, Guangyue; Xing, Junpeng; Song, Fengrui; Liu, Zhiqiang; Liu, Shuying
2014-12-01
In the present work, direct analysis of real time ionization combined with multi-stage tandem mass spectrometry (DART-MSn) was used to investigate the metabolic profile of aconite alkaloids in rat intestinal bacteria. A total of 36 metabolites from three aconite alkaloids were identified by using DART-MSn, and the feasibility of quantitative analysis of these analytes was examined. Key parameters of the DART ion source, such as helium gas temperature and pressure, the source-to-MS distance, and the speed of the autosampler, were optimized to achieve high sensitivity, enhance reproducibility, and reduce the occurrence of fragmentation. The instrument analysis time for one sample can be less than 10 s for this method. Compared with ESI-MS and UPLC-MS, the DART-MS is more efficient for directly detecting metabolic samples, and has the advantage of being a simple, high-speed, high-throughput method.
Li, Xue; Hou, Guangyue; Xing, Junpeng; Song, Fengrui; Liu, Zhiqiang; Liu, Shuying
2014-12-01
In the present work, direct analysis of real time ionization combined with multi-stage tandem mass spectrometry (DART-MS(n)) was used to investigate the metabolic profile of aconite alkaloids in rat intestinal bacteria. A total of 36 metabolites from three aconite alkaloids were identified by using DART-MS(n), and the feasibility of quantitative analysis of these analytes was examined. Key parameters of the DART ion source, such as helium gas temperature and pressure, the source-to-MS distance, and the speed of the autosampler, were optimized to achieve high sensitivity, enhance reproducibility, and reduce the occurrence of fragmentation. The instrument analysis time for one sample can be less than 10 s for this method. Compared with ESI-MS and UPLC-MS, the DART-MS is more efficient for directly detecting metabolic samples, and has the advantage of being a simple, high-speed, high-throughput method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chowdhury, Azhad U.; Ye, Dong Hye; Song, Zhengtian
Second harmonic generation (SHG) was integrated with Raman spectroscopy for the analysis of pharmaceutical materials. Particulate formulations of clopidogrel bisulfate were prepared in two crystal forms (Form I and Form II). Image analysis approaches enable automated identification of particles by bright field imaging, followed by classification by SHG. Quantitative SHG microscopy enabled discrimination of crystal form on a per particle basis with 99.95% confidence in a total measurement time of ~10 ms per particle. Complementary measurements by Raman and synchrotron XRD are in excellent agreement with the classifications made by SHG, with measurement times of ~1 min and several secondsmore » per particle, respectively. Coupling these capabilities with at-line monitoring may enable real-time feedback for reaction monitoring during pharmaceutical production to favor the more bioavailable but metastable Form I with limits of detection in the ppm regime.« less
Donaldson, K.A.; Griffin, Dale W.; Paul, J.H.
2002-01-01
A method was developed for the quantitative detection of pathogenic human enteroviruses from surface waters in the Florida Keys using Taqman (R) one-step Reverse transcription (RT)-PCR with the Model 7700 ABI Prism (R) Sequence Detection System. Viruses were directly extracted from unconcentrated grab samples of seawater, from seawater concentrated by vortex flow filtration using a 100kD filter and from sponge tissue. Total RNA was extracted from the samples, purified and concentrated using spin-column chromatography. A 192-196 base pair portion of the 5??? untranscribed region was amplified from these extracts. Enterovirus concentrations were estimated using real-time RT-PCR technology. Nine of 15 sample sites or 60% were positive for the presence of pathogenic human enteroviruses. Considering only near-shore sites, 69% were positive with viral concentrations ranging from 9.3viruses/ml to 83viruses/g of sponge tissue (uncorrected for extraction efficiency). Certain amplicons were selected for cloning and sequencing for identification. Three strains of waterborne enteroviruses were identified as Coxsackievirus A9, Coxsackievirus A16, and Poliovirus Sabin type 1. Time and cost efficiency of this one-step real-time RT-PCR methodology makes this an ideal technique to detect, quantitate and identify pathogenic enteroviruses in recreational waters. Copyright ?? 2002 Elsevier Science Ltd.
Doret, Muriel; Cartier, Régine; Miribel, Juliette; Massardier, Jérome; Massoud, Mona; Bordes, Agnès; Moret, Stéphanie; Gaucherand, Pascal
2013-12-01
Previable premature rupture of the membranes (pPROM), occurring before 24WG, is associated with a 25% neonatal survival rate. This terrible prognosis may lead to elective pregnancy termination on parents' request. Therefore, certain diagnosis is essential but remains difficult in about 10% of patients. Bed-side biochemical tests developed to help in diagnosis had never been evaluated in early pregnancies. This study aimed to evaluate and compare the in vitro sensitivity, detection limit, reaction time and consistency of AmniSure detecting placental alpha microglobulin-1 (PAMG-1) and actim PROM detecting Insulin Growth Factor Binding Protein-1 (IGFBP-1) in amniotic fluid between 15 and 20weeks of gestation (WG). Samples of amniotic fluid were collected by amniocentesis performed between 15 and 20 completed WG in 55 patients. Dilution series were prepared and both tests were performed twice at each dilution. In vitro sensitivity, detection limit, and reaction time were evaluated and compared in serial dilution. A total of 460 AmniSure and 476 actim PROM tests were performed. Both tests' in vitro sensitivity was 100% at dilution 1:20 and remained up to 90% until dilution 1:80. In vitro sensitivities were not different at any dilution. Detection limit and consistency were similar for both tests at all dilution. Actim PROM reaction time was shorter than AmniSure at all dilutions, except 1:320 (p<0.05). PAMG-1 and IGFBP-1 can be detected in amniotic fluid between 15 and 20 completed WG, using respectively AmniSure and actim PROM. © 2013.
Soverini, Simona; De Benedittis, Caterina; Castagnetti, Fausto; Gugliotta, Gabriele; Mancini, Manuela; Bavaro, Luana; Machova Polakova, Katerina; Linhartova, Jana; Iurlo, Alessandra; Russo, Domenico; Pane, Fabrizio; Saglio, Giuseppe; Rosti, Gianantonio; Cavo, Michele; Baccarani, Michele; Martinelli, Giovanni
2016-08-02
Imatinib-resistant chronic myeloid leukemia (CML) patients receiving second-line tyrosine kinase inhibitor (TKI) therapy with dasatinib or nilotinib have a higher risk of disease relapse and progression and not infrequently BCR-ABL1 kinase domain (KD) mutations are implicated in therapeutic failure. In this setting, earlier detection of emerging BCR-ABL1 KD mutations would offer greater chances of efficacy for subsequent salvage therapy and limit the biological consequences of full BCR-ABL1 kinase reactivation. Taking advantage of an already set up and validated next-generation deep amplicon sequencing (DS) assay, we aimed to assess whether DS may allow a larger window of detection of emerging BCR-ABL1 KD mutants predicting for an impending relapse. a total of 125 longitudinal samples from 51 CML patients who had acquired dasatinib- or nilotinib-resistant mutations during second-line therapy were analyzed by DS from the time of failure and mutation detection by conventional sequencing backwards. BCR-ABL1/ABL1%(IS) transcript levels were used to define whether the patient had 'optimal response', 'warning' or 'failure' at the time of first mutation detection by DS. DS was able to backtrack dasatinib- or nilotinib-resistant mutations to the previous sample(s) in 23/51 (45 %) pts. Median mutation burden at the time of first detection by DS was 5.5 % (range, 1.5-17.5 %); median interval between detection by DS and detection by conventional sequencing was 3 months (range, 1-9 months). In 5 cases, the mutations were detectable at baseline. In the remaining cases, response level at the time mutations were first detected by DS could be defined as 'Warning' (according to the 2013 ELN definitions of response to 2nd-line therapy) in 13 cases, as 'Optimal response' in one case, as 'Failure' in 4 cases. No dasatinib- or nilotinib-resistant mutations were detected by DS in 15 randomly selected patients with 'warning' at various timepoints, that later turned into optimal responders with no treatment changes. DS enables a larger window of detection of emerging BCR-ABL1 KD mutations predicting for an impending relapse. A 'Warning' response may represent a rational trigger, besides 'Failure', for DS-based mutation screening in CML patients undergoing second-line TKI therapy.
The majority of vitamin A is transported as retinyl esters in the blood of most carnivores.
Schweigert, F J; Ryder, O A; Rambeck, W A; Zucker, H
1990-01-01
1. In canines and mustelides total vitamin A was 10-50 times higher compared to other species due to a high amount of retinyl esters (40-99% of total vitamin A) in blood plasma. The dominant vitamin A ester was in most species retinyl stearate. 2. In Ursidae, Procyonidae, Viveridae and Felidae, total vitamin A was much lower. When present, however, retinyl esters also represented 10-65% of total vitamin A in plasma. 3. Only retinol was detected in plasma of the family, Hyaenidae, and the suborder, Pinnipedia. 4. In maned wolf cubs it was found that retinol, retinyl esters and alpha-tocopherol increased with the age of the animals, reaching values comparable to adult animals at the age of 5 months.
Asif, Muhammad; Rahman, Hazir; Qasim, Muhammad; Khan, Taj Ali; Ullah, Waheed; Jie, Yan
2017-05-01
Salmonella enteritidis infection is a frequently encountered zoonotic problem, occurring with concerning regularity in recent years on a worldwide basis. The study that we undertook for the first time detected S. enteritidis and associated antimicrobial resistance pattern in broiler chickens. A total of 150 different poultry samples were first enriched and grown on selective media, and then processed for molecular detection of S. enteritidis by amplification of the spvb gene. The overall detection rate of S. enteritidis was 23.3% (n=35), while an increased detection rate of S. enteritidis was found in the chicken breast tissue (n=9; 30%). When antibiogram was tested for S. enteritidis against common antibiotics, increased resistance to ampicillin (n=29; 82.2%), tetracycline (n=28; 80%), augmentin (n=27; 77.14%), and chloramphenicol (n=19; 54.2%) was observed. Multidrug resistance was reported in 54.8% (n=19) of the S. enteritidis isolates, while 20% (n=07) of isolates were extensively drug resistant. The present study for the first time reports S. enteritidis on the basis of spvb gene detection. The increased drug resistance in S. enteritidis is an emerging problem that could negatively impact efforts to prevent and treat broiler-transmitted S. enteritidis. Copyright © 2017. Published by Elsevier Taiwan LLC.
Numerical study on the sequential Bayesian approach for radioactive materials detection
NASA Astrophysics Data System (ADS)
Qingpei, Xiang; Dongfeng, Tian; Jianyu, Zhu; Fanhua, Hao; Ge, Ding; Jun, Zeng
2013-01-01
A new detection method, based on the sequential Bayesian approach proposed by Candy et al., offers new horizons for the research of radioactive detection. Compared with the commonly adopted detection methods incorporated with statistical theory, the sequential Bayesian approach offers the advantages of shorter verification time during the analysis of spectra that contain low total counts, especially in complex radionuclide components. In this paper, a simulation experiment platform implanted with the methodology of sequential Bayesian approach was developed. Events sequences of γ-rays associating with the true parameters of a LaBr3(Ce) detector were obtained based on an events sequence generator using Monte Carlo sampling theory to study the performance of the sequential Bayesian approach. The numerical experimental results are in accordance with those of Candy. Moreover, the relationship between the detection model and the event generator, respectively represented by the expected detection rate (Am) and the tested detection rate (Gm) parameters, is investigated. To achieve an optimal performance for this processor, the interval of the tested detection rate as a function of the expected detection rate is also presented.
Method and Apparatus for Monitoring of Daily Activity in Terms of Ground Reaction Forces
NASA Technical Reports Server (NTRS)
Whalen, Robert T. (Inventor); Breit, Gregory A. (Inventor)
2001-01-01
A device to record and analyze habitual daily activity in terms of the history of gait-related musculoskeletal loading is disclosed. The device consists of a pressure-sensing insole placed into the shoe or embedded in a shoe sole, which detects contact of the foot with the ground. The sensor is coupled to a portable battery-powered digital data logger clipped to the shoe or worn around the ankle or waist. During the course of normal daily activity, the system maintains a record of time-of-occurrence of all non-spurious foot-down and lift-off events. Off line, these data are filtered and converted to a history of foot-ground contact times, from which measures of cumulative musculoskeletal loading, average walking- and running-specific gait speed, total time spent walking and running, total number of walking steps and running steps, and total gait-related energy expenditure are estimated from empirical regressions of various gait parameters to the contact time reciprocal. Data are available as cumulative values or as daily averages by menu selection. The data provided by this device are useful for assessment of musculoskeletal and cardiovascular health and risk factors associated with habitual patterns of daily activity.
Mekki, Hemza; Benzineb, Omar; Boukhetala, Djamel; Tadjine, Mohamed; Benbouzid, Mohamed
2015-07-01
The fault-tolerant control problem belongs to the domain of complex control systems in which inter-control-disciplinary information and expertise are required. This paper proposes an improved faults detection, reconstruction and fault-tolerant control (FTC) scheme for motor systems (MS) with typical faults. For this purpose, a sliding mode controller (SMC) with an integral sliding surface is adopted. This controller can make the output of system to track the desired position reference signal in finite-time and obtain a better dynamic response and anti-disturbance performance. But this controller cannot deal directly with total system failures. However an appropriate combination of the adopted SMC and sliding mode observer (SMO), later it is designed to on-line detect and reconstruct the faults and also to give a sensorless control strategy which can achieve tolerance to a wide class of total additive failures. The closed-loop stability is proved, using the Lyapunov stability theory. Simulation results in healthy and faulty conditions confirm the reliability of the suggested framework. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.
GOES-16 Geostationary Lightning Mapper Comparison with the Earth Networks Total Lightning Network
NASA Astrophysics Data System (ADS)
Lapierre, J. L.; Stock, M.; Zhu, Y.
2017-12-01
Lightning location systems have shown to be an integral part of weather research and forecasting. The launch of the GOES-16 Geostationary Lightning Mapper (GLM) will provide a new tool to help improve lightning detection throughout the Americas and ocean regions. However, before this data can be effectively used, there must be a thorough analysis of its performance to validate the data it produces. Here, we compare GLM data to data from the Earth Networks Total Lightning Network (ENTLN). We analyze data during the months of May and June of 2017 to determine the detection efficiency of each system. A successful match occurs when two flashes overlap in time and are less than 0.2 degrees apart. Of the flashes detected by ENTLN, GLM detects about 50% overall. The highest DEs for GLM are over the ocean and South America, and lowest are in Central America and the Northeastern and Western parts of the U.S. Of the flashes detected by GLM, ENTLN detected over 80% in the Central and Eastern parts of the U.S. and 10-20% in Central and South America. Finally, we determined all the unique flashes detected by both systems and determined the DE of both systems from this unique flash dataset. We find that GLM does very well in South America, over the tropical islands in the Caribbean Sea as well as Northern U.S. It detects above 50% of the unique flashes over Central and off the Eastern Coast of the U.S. as well as in Mexico. GLM detects less than 50% of the unique flashes over Florida, the Mid-Atlantic, Mid-West, and Southwestern U.S., areas where ENTLN is expected to perform well.
Pierce, Virginia M.; Elkan, Michael; Leet, Marilyn; McGowan, Karin L.
2012-01-01
The FilmArray Respiratory Panel (RP) multiplexed nucleic acid amplification test (Idaho Technology, Inc., Salt Lake City, UT) was compared to laboratory-developed real-time PCR assays for the detection of various respiratory viruses and certain bacterial pathogens. A total of 215 frozen archived pediatric respiratory specimens previously characterized as either negative or positive for one or more pathogens by real-time PCR were examined using the FilmArray RP system. Overall agreement between the FilmArray RP and corresponding real-time PCR assays for shared analytes was 98.6% (kappa = 0.92 [95% confidence interval (CI), 0.89 to 0.94]). The combined positive percent agreement was 89.4% (95% CI, 85.4 to 92.6); the negative percent agreement was 99.6% (95% CI, 99.2 to 99.8). The mean real-time PCR threshold cycle (CT) value for specimens with discordant results was 36.46 ± 4.54. Detection of coinfections and correct identification of influenza A virus subtypes were comparable to those of real-time PCR when using the FilmArray RP. The greatest comparative difference in sensitivity was observed for adenovirus; only 11 of 24 (45.8%; 95% CI, 27.9 to 64.9) clinical specimens positive for adenovirus by real-time PCR were also positive by the FilmArray RP. In addition, upon testing 20 characterized adenovirus serotypes prepared at high and low viral loads, the FilmArray RP did not detect serotypes 6 and 41 at either level and failed to detect serotypes 2, 20, 35, and 37 when viral loads were low. The FilmArray RP system is rapid and extremely user-friendly, with results available in just over 1 h with almost no labor involved. Its low throughput is a significant drawback for laboratories receiving large numbers of specimens, as only a single sample can be processed at a time with one instrument. PMID:22116144
Fast CT-PRESS-based spiral chemical shift imaging at 3 Tesla.
Mayer, Dirk; Kim, Dong-Hyun; Adalsteinsson, Elfar; Spielman, Daniel M
2006-05-01
A new sequence is presented that combines constant-time point-resolved spectroscopy (CT-PRESS) with fast spiral chemical shift imaging. It allows the acquisition of multivoxel spectra without line splitting with a minimum total measurement time of less than 5 min for a field of view of 24 cm and a nominal 1.5x1.5-cm2 in-plane resolution. Measurements were performed with 17 CS encoding steps in t1 (Deltat1=12.8 ms) and an average echo time of 151 ms, which was determined by simulating the CT-PRESS experiment for the spin systems of glutamate (Glu) and myo-inositol (mI). Signals from N-acetyl-aspartate, total creatine, choline-containing compounds (Cho), Glu, and mI were detected in a healthy volunteer with no or only minor baseline distortions within 14 min on a 3 T MR scanner. Copyright (c) 2006 Wiley-Liss, Inc.
de Waal, Cornelia G; Kraaijenga, Juliette V; Hutten, Gerard J; de Jongh, Frans H; van Kaam, Anton H
2017-12-01
To compare triggering, breath detection and delay time of the Graseby capsule (GC) and transcutaneous electromyography of the diaphragm (dEMG) in spontaneous breathing preterm infants. In this observational study, a 30 minutes respiration measurement was conducted by respiratory inductance plethysmography (RIP), the GC, and dEMG in stable preterm infants. Triggering was investigated with an in vitro set-up using the Infant Flow ® SiPAP TM system. The possibility to optimize breath detection was tested by developing new algorithms with the abdominal RIP band (RIP AB ) as gold standard. In a subset of breaths, the delay time was calculated between the inspiratory onset in the RIP AB signal and in the GC and dEMG signal. Fifteen preterm infants with a mean gestational age of 28 ± 2 weeks and a mean birth weight of 1086 ± 317 g were included. In total, 14 773 breaths were analyzed. Based on the GC and dEMG signal, the Infant Flow ® SiPAP™ system, respectively, triggered 67.8% and 62.6% of the breaths. Breath detection was improved to 99.9% for the GC and 113.4% for dEMG in new algorithms. In 1492 stable breaths, the median delay time of inspiratory onset detection was +154 ms (IQR +118 to +164) in the GC and -50 ms (IQR -90 to -22) in the dEMG signal. Breath detection using the GC can be improved by optimizing the algorithm. Transcutaneous dEMG provides similar breath detection but with the advantage of detecting the onset of inspiration earlier than the GC. © 2017 Wiley Periodicals, Inc.
Okumura, Tomoo; Fujita, Hiroshi; Harada, Hideto; Nishimura, Ryuuichi; Tominaga, Tomohiro
2017-02-01
A 79-year-old woman was diagnosed with osteoarthritis of the left hip and scheduled for total hip arthroplasty. As two lesions were detected in branches of the coronary arteries, she was treated with catheter treatment. The patient was receiving anticoagulant treatment, which was suspended eight days before the operation; however, heparin was started at 6 days before the operation and was stopped 9 hours before the operation. On the 2nd postoperative day soon after transfer to the wheel chair, she was feeling unwell and was suffering from severe pain in her left buttock and left thigh. Her blood pressure had decreased to 70 mmHg. During abdominal contrast-enhanced CT, a hematoma was detected in the left iliopsoas muscle. Catheter therapy was started by the cardiovascular department and bleeding had stopped spontaneously. The patient was able to walk with a cane and was discharged on the 40th postoperative day. THA: total hip arthroplasty, CT: computed tomography, JOA score: Japanese Orthopaedic Association hip score, HA: hydroxyapatite, PMMA: polymethyl-methacrylate, APTT: activated partial thromboplastin time.
Predominant bacteria in an activated sludge reactor for the degradation of cutting fluids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, C.A.; Claus, G.W.; Taylor, P.A.
1983-01-01
For the first time, an activated sludge reactor, established for the degradation of cutting fluids, was examined for predominant bacteria. In addition, both total and viable numbers of bacteria in the reactor were determined so that the percentage of each predominant type in the total reactor population could be determined. Three samples were studied, and a total of 15 genera were detected. In each sample, the genus Pseudomonas and the genus Microcyclus were present in high numbers. Three other genera, Acinetobacter, Alcaligenes, and Corynebacterium, were also found in every sample but in lower numbers. In one sample, numerous appendage bacteriamore » were present, and one of these, the genus Seliberia, was the most predominant organism in that sample. However, in the other two samples no appendage bacteria were detected. Six genera were found in this reactor which have not been previously reported in either cutting fluids in use or in other activated sludge systems. These genera were Aeromonas, Hyphomonas, Listeria, Microcyclus, Moraxella, and Spirosoma. None of the predominant bacterial belonged to groups of strict pathogens. 22 references, 6 figures, 3 tables.« less
Kokoris, M; Nabavi, M; Lancaster, C; Clemmens, J; Maloney, P; Capadanno, J; Gerdes, J; Battrell, C F
2005-09-01
One current challenge facing point-of-care cancer detection is that existing methods make it difficult, time consuming and too costly to (1) collect relevant cell types directly from a patient sample, such as blood and (2) rapidly assay those cell types to determine the presence or absence of a particular type of cancer. We present a proof of principle method for an integrated, sample-to-result, point-of-care detection device that employs microfluidics technology, accepted assays, and a silica membrane for total RNA purification on a disposable, credit card sized laboratory-on-card ('lab card") device in which results are obtained in minutes. Both yield and quality of on-card purified total RNA, as determined by both LightCycler and standard reverse transcriptase amplification of G6PDH and BCR-ABL transcripts, were found to be better than or equal to accepted standard purification methods.
García Robles, Reggie; Rojas, Juan Diego; Bermúdez, Martha; Bernal, Jaime
2012-01-01
Objective: to quantify placenta-specific RNA in plasma of women carrying foetuses with intrauterine growth restriction and pregnant women with normal pregnancies. Methods: 8 pregnant women with foetuses with intrauterine growth restriction were studied as well as 18 women with uncomplicated pregnancies in the third pregnancy trimester. Total free RNA was quantified in maternal plasma by spectrophotometry and the gene expression of hPL (Human Placental Lactogen) at the messenger RNA level through technical Real Time-Chain Reaction Polymerase. Results: plasma RNA of fetoplacental origin was successfully detected in 100% of pregnant women. There were no statistically significant differences between the values of total RNA extracted from plasma (p= 0.5975) nor in the messenger RNA expression of hPL gene (p= 0.5785) between cases and controls. Conclusion: messenger RNA of fetoplacental origin can be detected in maternal plasma during pregnancy. PMID:24893189
Ayala Ramírez, Paola; García Robles, Reggie; Rojas, Juan Diego; Bermúdez, Martha; Bernal, Jaime
2012-07-01
to quantify placenta-specific RNA in plasma of women carrying foetuses with intrauterine growth restriction and pregnant women with normal pregnancies. 8 pregnant women with foetuses with intrauterine growth restriction were studied as well as 18 women with uncomplicated pregnancies in the third pregnancy trimester. Total free RNA was quantified in maternal plasma by spectrophotometry and the gene expression of hPL (Human Placental Lactogen) at the messenger RNA level through technical Real Time-Chain Reaction Polymerase. plasma RNA of fetoplacental origin was successfully detected in 100% of pregnant women. There were no statistically significant differences between the values of total RNA extracted from plasma (p= 0.5975) nor in the messenger RNA expression of hPL gene (p= 0.5785) between cases and controls. messenger RNA of fetoplacental origin can be detected in maternal plasma during pregnancy.
Newly found evidence of Sun-climate relationships
NASA Technical Reports Server (NTRS)
Kim, Hongsuk H.; Huang, Norden E.
1993-01-01
Solar radiation cycles drive climatic changes intercyclically. These interdecadal changes were detected as variations in solar total irradiances over the time period of recorded global surface-air-temperature (SAT) and have been restored utilizing Earth Radiation Budget Channel 10C measurements (1978-1990), Greenwich Observatory faculae data (1874-1975), and Taipei Observatory Active Region data (1964-1991). Analysis of the two separate events was carried out by treating each as a discrete time series determined by the length of each solar cycle. The results show that the global SAT responded closely to the input of solar cyclical activities, S, with a quantitative relation of T = 1.62 * S with a correlation coefficient of 0.61. This correlation peaks at 0.71 with a built-in time lag of 32 months in temperature response. Solar forcing in interannual time scale was also detected and the derived relationship of T = 0.17 * S with a correlation coefficient of 0.66 was observed. Our analysis shows derived climate sensitivities approximately fit the theoretical feedback slope, 4T(sup 3).
Fleischer, Luise; Sehner, Susanne; Gehl, Axel; Riemer, Martin; Raupach, Tobias; Anders, Sven
2017-05-01
Measurement of postmortem pupil width is a potential component of death time estimation. However, no standardized measurement method has been described. We analyzed a total of 71 digital images for pupil-iris ratio using the software ImageJ. Images were analyzed three times by four different examiners. In addition, serial images from 10 cases were taken between 2 and 50 h postmortem to detect spontaneous pupil changes. Intra- and inter-rater reliability of the method was excellent (ICC > 0.95). The method is observer independent and yields consistent results, and images can be digitally stored and re-evaluated. The method seems highly eligible for forensic and scientific purposes. While statistical analysis of spontaneous pupil changes revealed a significant polynomial of quartic degree for postmortem time (p = 0.001), an obvious pattern was not detected. These results do not indicate suitability of spontaneous pupil changes for forensic death time estimation, as formerly suggested. © 2016 American Academy of Forensic Sciences.
[Estimation of time detection limit for human cytochrome b in females of Lutzomyia evansi].
Vergara, José Gabriel; Verbel-Vergara, Daniel; Montesino, Ana Milena; Pérez-Doria, Alveiro; Bejarano, Eduar Elías
2017-03-29
Molecular biology techniques have allowed a better knowledge of sources of blood meals in vector insects. However, the usefulness of these techniques depends on both the quantity of ingested blood and the digestion process in the insect. To identify the time limit for detection of the human cytochrome b (Cyt b) gene in experimentally fed females of Lutzomyia evansi. Eight groups of L. evansi females were fed on human blood and sacrificed at intervals of 24 hours post-ingestion. Total DNA was extracted from each female and a segment of 358 bp of Cyt b was amplified. In order to eliminate false positives, amplification products were subjected to a restriction fragment length polymorphism (RFLP) analysis. The human Cyt b gene segment was detected in 86% (49/57) of the females of L. evansi, from 0 to 168 hours after blood ingestion. In 7% (4/57) of the individuals we amplified insect DNA, while in the remaining 7%, the band of interest was not amplified. We did not find any statistical differences between groups of females sacrificed at different times post-blood meal regarding the amplification of the human Cyt b gene segment or the number of samples amplified. The human Cyt b gene segment was detectable in L. evansi females up to 168 hours after blood ingestion.
A real-time PCR approach to detect predation on anchovy and sardine early life stages
NASA Astrophysics Data System (ADS)
Cuende, Elsa; Mendibil, Iñaki; Bachiller, Eneko; Álvarez, Paula; Cotano, Unai; Rodriguez-Ezpeleta, Naiara
2017-12-01
Recruitment of sardine (Sardina pilchardus Walbaum, 1792) and anchovy (Engraulis encrasicolus Linnaeus, 1758) is thought to be regulated by predation of their eggs and larvae. Predators of sardine and anchovy can be identified by visual taxonomic identification of stomach contents, but this method is time consuming, tedious and may underestimate predation, especially in small predators such as fish larvae. Alternatively, genetic tools may offer a more cost-effective and accurate alternative. Here, we have developed a multiplex real-time polymerase chain reaction (RT-PCR) assay based on TaqMan probes to simultaneously detect sardine and anchovy remains in gut contents of potential predators. The assay combines previously described and newly generated species-specific primers and probes for anchovy and sardine detection respectively, and allows the detection of 0,001 ng of target DNA (which corresponds to about one hundredth of the total DNA present in a single egg). We applied the method to candidate anchovy and sardine egg predators in the Bay of Biscay, Atlantic Mackerel (Scomber scombrus) larvae. Egg predation observed was limited primarily to those stations where sardine and/or anchovy eggs were present. Our developed assay offers a suitable tool to understand the effects of predation on the survival of anchovy and sardine early life stages.
The long-term changes in total ozone, as derived from Dobson measurements at Arosa (1948-2001)
NASA Astrophysics Data System (ADS)
Krzyscin, J. W.
2003-04-01
The longest possible total ozone time series (Arosa, Switzerland) is examined for a detection of trends. Two-step procedure is proposed to estimate the long-term (decadal) variations in the ozone time series. The first step consists of a standard least-squares multiple regression applied to the total ozone monthly means to parameterize "natural" (related to the oscillations in the atmospheric dynamics) variations in the analyzed time series. The standard proxies for the dynamical ozone variations are used including; the 11-year solar activity cycle, and indices of QBO, ENSO and NAO. We use the detrended time series of temperature at 100 hPa and 500 hPa over Arosa to parameterize short-term variations (with time periods<1 year) in total ozone related to local changes in the meteorological conditions over the station. The second step consists of a smooth-curve fitting to the total ozone residuals (original minus modeled "natural" time series), the time derivation applied to this curve to obtain local trends, and bootstrapping of the residual time series to estimate the standard error of local trends. Locally weighted regression and the wavelet analysis methodology are used to extract the smooth component out of the residual time series. The time integral over the local trend values provides the cumulative long-term change since the data beginning. Examining the pattern of the cumulative change we see the periods with total ozone loss (the end of 50s up to early 60s - probably the effect of the nuclear bomb tests), recovery (mid 60s up to beginning of 70s), apparent decrease (beginning of 70s lasting to mid 90s - probably the effect of the atmosphere contamination by anthropogenic substances containing chlorine), and with a kind of stabilization or recovery (starting in the mid of 90s - probably the effect of the Montreal protocol to eliminate substances reducing the ozone layer). We can also estimate that a full ozone recovery (return to the undisturbed total ozone level from the beginning of 70s) is expected around 2050. We propose to calculate both time series of local trends and the cumulative long-term change instead single trend value derived as a slope of straight line fit to the data.
Clustering ENTLN sferics to improve TGF temporal analysis
NASA Astrophysics Data System (ADS)
Pradhan, E.; Briggs, M. S.; Stanbro, M.; Cramer, E.; Heckman, S.; Roberts, O.
2017-12-01
Using TGFs detected with Fermi Gamma-ray Burst Monitor (GBM) and simultaneous radio sferics detected by Earth Network Total Lightning Network (ENTLN), we establish a temporal co-relation between them. The first step is to find ENTLN strokes that that are closely associated to GBM TGFs. We then identify all the related strokes in the lightning flash that the TGF-associated-stroke belongs to. After trying several algorithms, we found out that the DBSCAN clustering algorithm was best for clustering related ENTLN strokes into flashes. The operation of DBSCAN was optimized using a single seperation measure that combined time and distance seperation. Previous analysis found that these strokes show three timescales with respect to the gamma-ray time. We will use the improved identification of flashes to research this.
Near instrument-free, simple molecular device for rapid detection of herpes simplex viruses.
Lemieux, Bertrand; Li, Ying; Kong, Huimin; Tang, Yi-Wei
2012-06-01
The first near instrument-free, inexpensive and simple molecular diagnostic device (IsoAmp HSV, BioHelix Corp., MA, USA) recently received US FDA clearance for use in the detection of herpes simplex viruses (HSV) in genital and oral lesion specimens. The IsoAmp HSV assay uses isothermal helicase-dependent amplification in combination with a disposable, hermetically-sealed, vertical-flow strip identification. The IsoAmp HSV assay has a total test-to-result time of less than 1.5 h by omitting the time-consuming nucleic acid extraction. The diagnostic sensitivity and specificity are comparable to PCR and are superior to culture-based methods. The near instrument-free, rapid and simple characteristics of the IsoAmp HSV assay make it potentially suitable for point-of-care testing.
NASA Astrophysics Data System (ADS)
Feliciano Crespo, Raquel; Perales Perez, Oscar Juan; Ramirez, C.
2018-05-01
Health diseases due to the ingestion of water or food contaminated with pathogenic microorganisms are a main health problem around the world. The traditional methods for detecting foodborne pathogens are time-consuming (on the order of days). The development of methods that can help to detect and identify foodborne pathogens with high sensitivity and specificity have been proposed to overcome the limitations of traditional methods. Accordingly, this research is focused on the development of an experimental protocol for a high-sensitivity detection and quantification of bacterial pathogens with reduced detection times. This will lead to the development of a portable and low-cost technology with the opportunity to make onsite detection of pathogenic species. The proposed approach has modified the route reported in the literature; the method proposed is expected to be sensitive enough to detect a low limit of 102 CFU/mL counts of bacteria. The fluorescence-based method was tested in presence of Salmonella typhimurium (ATCC 14020) and Escherichia coli (ATCC 25922). CdSe water-soluble quantum dots (QDs) were synthesized in aqueous phase in presence of thioglycolic acid (TGA) as a capping agent. As-synthesized QDs were characterized by x-ray diffraction, near infrared and Fourier transform infrared spectroscopy, UV-Vis and photoluminescence techniques. Results of the CdSe/TGA-bacteria coupling and the determination of the corresponding quantification profiles (calibration curves) will be presented and discussed.
Multicenter Clinical Evaluation of BacT/Alert Virtuo Blood Culture System.
Jacobs, Michael R; Mazzulli, Tony; Hazen, Kevin C; Good, Caryn E; Abdelhamed, Ayman M; Lo, Pauline; Shum, Bianche; Roman, Katharine P; Robinson, Danielle C
2017-08-01
BacT/Alert Virtuo is an advanced, automated blood culture system incorporating improved automation and an enhanced detection algorithm to shorten time to detection. A multicenter study of the investigational Virtuo system (bioMérieux, Inc., Durham, NC) compared to BacT/Alert 3D (BTA3D) for detection of bacteremia/fungemia in four bottle types, SA and FA Plus (aerobic) and SN and FN Plus (anaerobic), was performed in a clinical setting with patient samples in a matched system design clinical trial. Blood was added to paired aerobic or anaerobic bottles, with the volume in each bottle in each pair required to be ≤10 ml and with the volumes required to be within 30% of each other. Of 5,709 bottle sets (52.5% aerobic pairs and 47.5% anaerobic pairs), 430 (7.5%) were positive for bacterial or fungal growth, with 342 (6.0%) clinically significant and 83 (1.5%) contaminated. A total of 3,539 sets (62.0%) were volume compliant, with 203 sets (5.7%) clinically significant. The positivity rates for volume-compliant bottle pairs determined by the two systems were comparable, with 68.7% of clinically significant isolates detected by both instruments, 15.7% by Virtuo only, and 15.7% by BTA3D only. Virtuo detected microbial growth nearly 2 h sooner overall than BTA3D (mean, 15.9 h versus 17.7 h). Shorter time to detection by Virtuo was related to organism group, with the time to detection being significantly shorter for enteric Gram-negative bacilli and enterococci (means, 3.6 h and 2.3 h shorter, respectively). This large clinical study demonstrated that the Virtuo blood culture system produced results comparable to those seen with the long-established BTA3D system, with significantly shorter time to detection. Copyright © 2017 Jacobs et al.
Slavin, Margaret; Lu, Yingjian; Kaplan, Nicholas; Yu, Liangli Lucy
2013-11-15
Black soybean is a potential functional food ingredient with high anthocyanin content, but the ability to maintain anthocyanin content under dry heat processing has not been reported. This study investigated the effects of soybean seed coat colour and baking time-temperature combinations on the extractable antioxidant properties of a soy cracker food model. Crackers prepared with black soybeans had significantly higher TPC, total isoflavones, and peroxyl, hydroxyl, and ABTS(+) radical scavenging abilities than their yellow counterparts, at all time-temperature combinations. Cyanidin-3-glucoside (C3G) was detected only in black soybean crackers, and all baking treatments significantly decreased C3G. The greatest losses occurred at the low temperature×long time and high temperature×short time, the smallest loss with moderate temperature×short/medium time. The high temperature treatment altered phenolic acid and isoflavone profiles; however, total isoflavones were unaffected. Overall results suggest that moderate baking temperature at minimal time may best preserve anthocyanin and other phenolics in baked black soybean crackers. Copyright © 2013 Elsevier Ltd. All rights reserved.
Ionospheric earthquake effects detection based on Total Electron Content (TEC) GPS Correlation
NASA Astrophysics Data System (ADS)
Sunardi, Bambang; Muslim, Buldan; Eka Sakya, Andi; Rohadi, Supriyanto; Sulastri; Murjaya, Jaya
2018-03-01
Advances in science and technology showed that ground-based GPS receiver was able to detect ionospheric Total Electron Content (TEC) disturbances caused by various natural phenomena such as earthquakes. One study of Tohoku (Japan) earthquake, March 11, 2011, magnitude M 9.0 showed TEC fluctuations observed from GPS observation network spread around the disaster area. This paper discussed the ionospheric earthquake effects detection using TEC GPS data. The case studies taken were Kebumen earthquake, January 25, 2014, magnitude M 6.2, Sumba earthquake, February 12, 2016, M 6.2 and Halmahera earthquake, February 17, 2016, M 6.1. TEC-GIM (Global Ionosphere Map) correlation methods for 31 days were used to monitor TEC anomaly in ionosphere. To ensure the geomagnetic disturbances due to solar activity, we also compare with Dst index in the same time window. The results showed anomalous ratio of correlation coefficient deviation to its standard deviation upon occurrences of Kebumen and Sumba earthquake, but not detected a similar anomaly for the Halmahera earthquake. It was needed a continous monitoring of TEC GPS data to detect the earthquake effects in ionosphere. This study giving hope in strengthening the earthquake effect early warning system using TEC GPS data. The method development of continuous TEC GPS observation derived from GPS observation network that already exists in Indonesia is needed to support earthquake effects early warning systems.
GNSS Observations of Ionospheric Variations During the 21 August 2017 Solar Eclipse
NASA Astrophysics Data System (ADS)
Coster, Anthea J.; Goncharenko, Larisa; Zhang, Shun-Rong; Erickson, Philip J.; Rideout, William; Vierinen, Juha
2017-12-01
On 21 August 2017, during daytime hours, a total solar eclipse with a narrow ˜160 km wide umbral shadow occurred across the continental United States. Totality was observed from the Oregon coast at ˜9:15 local standard time (LST) (17:20 UT) to the South Carolina coast at ˜13:27 LST (18:47 UT). A dense network of Global Navigation Satellite Systems (GNSS) receivers was utilized to produce total electron content (TEC) and differential TEC. These data were analyzed for the latitudinal and longitudinal response of the TEC and for the presence of traveling ionospheric disturbances (TIDs) during eclipse passage. A significant TEC depletion, in some cases greater than 60%, was observed associated with the eclipse shadow, exceeding initial model predictions of 35%. Evidence of enhanced large-scale TID activity was detected over the United States prior to and following the large TEC depletion observed near the time of totality. Signatures of enhanced TEC structures were observed over the Rocky Mountain chain during the main period of TEC depletion.
Scheutz, Flemming; Lund, Ole; Hasman, Henrik; Kaas, Rolf S.; Nielsen, Eva M.; Aarestrup, Frank M.
2014-01-01
Fast and accurate identification and typing of pathogens are essential for effective surveillance and outbreak detection. The current routine procedure is based on a variety of techniques, making the procedure laborious, time-consuming, and expensive. With whole-genome sequencing (WGS) becoming cheaper, it has huge potential in both diagnostics and routine surveillance. The aim of this study was to perform a real-time evaluation of WGS for routine typing and surveillance of verocytotoxin-producing Escherichia coli (VTEC). In Denmark, the Statens Serum Institut (SSI) routinely receives all suspected VTEC isolates. During a 7-week period in the fall of 2012, all incoming isolates were concurrently subjected to WGS using IonTorrent PGM. Real-time bioinformatics analysis was performed using web-tools (www.genomicepidemiology.org) for species determination, multilocus sequence type (MLST) typing, and determination of phylogenetic relationship, and a specific VirulenceFinder for detection of E. coli virulence genes was developed as part of this study. In total, 46 suspected VTEC isolates were characterized in parallel during the study. VirulenceFinder proved successful in detecting virulence genes included in routine typing, explicitly verocytotoxin 1 (vtx1), verocytotoxin 2 (vtx2), and intimin (eae), and also detected additional virulence genes. VirulenceFinder is also a robust method for assigning verocytotoxin (vtx) subtypes. A real-time clustering of isolates in agreement with the epidemiology was established from WGS, enabling discrimination between sporadic and outbreak isolates. Overall, WGS typing produced results faster and at a lower cost than the current routine. Therefore, WGS typing is a superior alternative to conventional typing strategies. This approach may also be applied to typing and surveillance of other pathogens. PMID:24574290
Chen, J H K; She, K K K; Kwong, T-C; Wong, O-Y; Siu, G K H; Leung, C-C; Chang, K-C; Tam, C-M; Ho, P-L; Cheng, V C C; Yuen, K-Y; Yam, W-C
2015-09-01
The automated high-throughput Abbott RealTime MTB real-time PCR assay has been recently launched for Mycobacterium tuberculosis complex (MTBC) clinical diagnosis. This study would like to evaluate its performance. We first compared its diagnostic performance with the Roche Cobas TaqMan MTB assay on 214 clinical respiratory specimens. Prospective analysis of a total 520 specimens was then performed to further evaluate the Abbott assay. The Abbott assay showed a lower limit of detection at 22.5 AFB/ml, which was more sensitive than the Cobas assay (167.5 AFB/ml). The two assays demonstrated a significant difference in diagnostic performance (McNemar's test; P = 0.0034), in which the Abbott assay presented significantly higher area under curve (AUC) than the Cobas assay (1.000 vs 0.880; P = 0.0002). The Abbott assay demonstrated extremely low PCR inhibition on clinical respiratory specimens. The automated Abbott assay required only very short manual handling time (0.5 h), which could help to improve the laboratory management. In the prospective analysis, the overall estimates for sensitivity and specificity of the Abbott assay were both 100 % among smear-positive specimens, whereas the smear-negative specimens were 96.7 and 96.1 %, respectively. No cross-reactivity with non-tuberculosis mycobacterial species was observed. The superiority in sensitivity of the Abbott assay for detecting MTBC in smear-negative specimens could further minimize the risk in MTBC false-negative detection. The new Abbott RealTime MTB assay has good diagnostic performance which can be a useful diagnostic tool for rapid MTBC detection in clinical laboratories.
High resolution TaqMan real-time PCR approach to detect hazelnut DNA encoding for ITS rDNA in foods.
López-Calleja, Inés María; de la Cruz, Silvia; Pegels, Nicolette; González, Isabel; García, Teresa; Martín, Rosario
2013-12-01
A broad range of foods have been described as causing allergies, but the majority of allergic reactions can be ascribed to a limited number of food components. Recent extensive surveys showed how tree nuts, particularly hazelnut (Corylus avellana L.) seeds, rank amongst the most important sources of food allergy. In order to protect the allergic consumer, efficient and reliable methods are required for the detection of allergenic ingredients. For this purpose, we have developed a real-time polymerase chain reaction (PCR) for detection of hazelnut in commercial food products. In this way a specific hazelnut primer pair based on the ITS marker (70 bp) and a nuclease (TaqMan) probe labelled with FAM and BHQ were designed. Sensibility of real-time PCR was determined by analysis of raw and heat treated hazelnut-wheat flour mixtures with a range of detection of 0.1-100,000 ppm. Practical applicability of the real-time PCR assay developed for determining hazelnut in different food matrices was investigated by analyzing 179 commercial foodstuffs comprising snacks, biscuits, chocolates, bonbons, creams, nut bars, ice creams, precooked meals, breads, beverages, yogurts, cereals, meat products, rice cake and nougat. From the total of samples analyzed, 40 commercial food products that didn't declare hazelnut nor traces on the label were found to contain hazelnut. The real-time PCR method proposed herein due to its high sensitivity facilitates the detection of hazelnut traces in commercial food products and can also be useful for monitoring the effectiveness of cleaning processes and as consequence, can help to prevent the food allergic consumer from unintentional ingestion of hidden allergens. Copyright © 2013 Elsevier Ltd. All rights reserved.
Upper limit set for level of lightning activity on Titan
NASA Technical Reports Server (NTRS)
Desch, M. D.; Kaiser, M. L.
1990-01-01
Because optically thick cloud and haze layers prevent lightning detection at optical wavelength on Titan, a search was conducted for lightning-radiated signals (spherics) at radio wavelengths using the planetary radioastronomy instrument aboard Voyager 1. Given the maximum ionosphere density of about 3000/cu cm, lightning spherics should be detectable above an observing frequency of 500 kHz. Since no evidence for spherics is found, an upper limit to the total energy per flash in Titan lightning of about 10 to the 6th J, or about 1000 times weaker than that of typical terrestrial lightning, is inferred.
Retention time alignment of LC/MS data by a divide-and-conquer algorithm.
Zhang, Zhongqi
2012-04-01
Liquid chromatography-mass spectrometry (LC/MS) has become the method of choice for characterizing complex mixtures. These analyses often involve quantitative comparison of components in multiple samples. To achieve automated sample comparison, the components of interest must be detected and identified, and their retention times aligned and peak areas calculated. This article describes a simple pairwise iterative retention time alignment algorithm, based on the divide-and-conquer approach, for alignment of ion features detected in LC/MS experiments. In this iterative algorithm, ion features in the sample run are first aligned with features in the reference run by applying a single constant shift of retention time. The sample chromatogram is then divided into two shorter chromatograms, which are aligned to the reference chromatogram the same way. Each shorter chromatogram is further divided into even shorter chromatograms. This process continues until each chromatogram is sufficiently narrow so that ion features within it have a similar retention time shift. In six pairwise LC/MS alignment examples containing a total of 6507 confirmed true corresponding feature pairs with retention time shifts up to five peak widths, the algorithm successfully aligned these features with an error rate of 0.2%. The alignment algorithm is demonstrated to be fast, robust, fully automatic, and superior to other algorithms. After alignment and gap-filling of detected ion features, their abundances can be tabulated for direct comparison between samples.
Catelani, Tiago A; Santos, João Rodrigo; Páscoa, Ricardo N M J; Pezza, Leonardo; Pezza, Helena R; Lopes, João A
2018-03-01
This work proposes the use of near infrared (NIR) spectroscopy in diffuse reflectance mode and multivariate statistical process control (MSPC) based on principal component analysis (PCA) for real-time monitoring of the coffee roasting process. The main objective was the development of a MSPC methodology able to early detect disturbances to the roasting process resourcing to real-time acquisition of NIR spectra. A total of fifteen roasting batches were defined according to an experimental design to develop the MSPC models. This methodology was tested on a set of five batches where disturbances of different nature were imposed to simulate real faulty situations. Some of these batches were used to optimize the model while the remaining was used to test the methodology. A modelling strategy based on a time sliding window provided the best results in terms of distinguishing batches with and without disturbances, resourcing to typical MSPC charts: Hotelling's T 2 and squared predicted error statistics. A PCA model encompassing a time window of four minutes with three principal components was able to efficiently detect all disturbances assayed. NIR spectroscopy combined with the MSPC approach proved to be an adequate auxiliary tool for coffee roasters to detect faults in a conventional roasting process in real-time. Copyright © 2017 Elsevier B.V. All rights reserved.
Neutron detection using a crystal ball calorimeter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martem’yanov, M. A., E-mail: mmartemi@gmail.com; Kulikov, V. V.; Krutenkova, A. P.
2015-12-15
The program of experiments of the A2 Collaboration performed on a beam of tagged photons of the MAMI electron microtron in Mainz (Germany) includes precision measurements of the total and differential cross sections of the pion photoproduction on neutrons of a deuterium target. The determination of the detector ability to detect neutrons is undoubtedly one of the important problems of the experiment. The calorimetric system of the detector contains a segmented NaI Crystal Ball detector, which gives information about the position, energy, and detection time of neutral and charged particles in a wide angular range. In this work, we describemore » the measurement of the neutron detection efficiency in the energy range from 20 to 400MeV. The results are compared with BNL data obtained on a pion beam and proton target.« less
Testing the importance of auditory detections in avian point counts
Brewster, J.P.; Simons, T.R.
2009-01-01
Recent advances in the methods used to estimate detection probability during point counts suggest that the detection process is shaped by the types of cues available to observers. For example, models of the detection process based on distance-sampling or time-of-detection methods may yield different results for auditory versus visual cues because of differences in the factors that affect the transmission of these cues from a bird to an observer or differences in an observer's ability to localize cues. Previous studies suggest that auditory detections predominate in forested habitats, but it is not clear how often observers hear birds prior to detecting them visually. We hypothesized that auditory cues might be even more important than previously reported, so we conducted an experiment in a forested habitat in North Carolina that allowed us to better separate auditory and visual detections. Three teams of three observers each performed simultaneous 3-min unlimited-radius point counts at 30 points in a mixed-hardwood forest. One team member could see, but not hear birds, one could hear, but not see, and the third was nonhandicapped. Of the total number of birds detected, 2.9% were detected by deafened observers, 75.1% by blinded observers, and 78.2% by nonhandicapped observers. Detections by blinded and nonhandicapped observers were the same only 54% of the time. Our results suggest that the detection of birds in forest habitats is almost entirely by auditory cues. Because many factors affect the probability that observers will detect auditory cues, the accuracy and precision of avian point count estimates are likely lower than assumed by most field ornithologists. ?? 2009 Association of Field Ornithologists.
Characterization of time dynamical evolution of electroencephalographic epileptic records
NASA Astrophysics Data System (ADS)
Rosso, Osvaldo A.; Mairal, María. Liliana
2002-09-01
Since traditional electrical brain signal analysis is mostly qualitative, the development of new quantitative methods is crucial for restricting the subjectivity in the study of brain signals. These methods are particularly fruitful when they are strongly correlated with intuitive physical concepts that allow a better understanding of the brain dynamics. The processing of information by the brain is reflected in dynamical changes of the electrical activity in time, frequency, and space. Therefore, the concomitant studies require methods capable of describing the qualitative variation of the signal in both time and frequency. The entropy defined from the wavelet functions is a measure of the order/disorder degree present in a time series. In consequence, this entropy evaluates over EEG time series gives information about the underlying dynamical process in the brain, more specifically of the synchrony of the group cells involved in the different neural responses. The total wavelet entropy results independent of the signal energy and becomes a good tool for detecting dynamical changes in the system behavior. In addition the total wavelet entropy has advantages over the Lyapunov exponents, because it is parameter free and independent of the stationarity of the time series. In this work we compared the results of the time evolution of the chaoticity (Lyapunov exponent as a function of time) with the corresponding time evolution of the total wavelet entropy in two different EEG records, one provide by depth electrodes and other by scalp ones.
Deng, Min-zhen; Huang, Li-ping; Fang, Yong-qi
2015-05-01
To observe the effects of the co-administration of total ginsenosides and volatile oil of Acorus tatarinowii on the ability of learning and memory and apoptosis in Alzheimer's disease (AD) mice model induced by D-galactose and aluminium chloride. 50 Kunming (KM) mice were randomly divided into normal group, model group, Aricept group (1 mg/kg), Ding Zhi Wan group (10 g/kg) and co-administration of total ginsenosides and volatile oil of Acorus tatarinowii group (co-administered group, the doses of volatile oil of Acorus tatarinowii and total ginsenosides were 30 mg/kg and 150 mg/kg, respectively). In addition to normal group, mice in other groups were given D-galactose 150 mg/ (kg x d), ip, and aluminium chloride 5 mg/kg, ig, once daily for 40 days. At the same time, mice in the treated groups were administrated with the corresponding drug from the 20th day after the modeling, once daily for 40 days. Water maze and avoiding darkness experiments were used to test learning and memory abilities; Aβ1-42 and BCL-2 content in cortex and hippocampus were detected by ELISA; the vitalities of acetyl cholinesterase ( AChE) and acetylcholine transferase (ChAT) were detected by ultraviolet spectrophotometry. Superoxide dismutase (SOD) vitalities were detected by a water-soluble tetrazolium salt (WST-1) method; the content of malondialdehyde ( MDA) in cortex and hippocampus were detected by the thiobarbituric acid (TBA) method; senile plaque on Aβ1-42 precipitation were observed by immunohistochemistry; brain tissues were observed by hematoxylin-eosin staining (HE). As compared with model group, in the co-administered group, the time of AD mice swimming, the numbers of blind area and electric shock reduced significantly (P < 0.05), and the latent period was prolonged (P < 0.05); AChE activity and levels of Aβ1-42 and MDA in cortex and hippocampus were decreased significantly (P < 0.05 or P < 0.01); ChAT and SOD activities as well as BCL-2 content were increased significantly (P < 0.05 or P < 0.01) the formation of senile plaque was decreased and brain tissue morphology was improved. Total ginsenosides and volatile oil of Acorus tatarinowii co-administration has an effect on improving the ability of learning and memory and inhibiting apoptosis.
Wang, Zheng; Wu, Xiaonan; Shi, Yuankai; Han, Xiaohong; Cheng, Gang; Cui, Di; Li, Lin; Zhang, Yuhui; Mu, Xinlin; Zhang, Li; Yang, Li; Di, Jing; Yu, Qi; Liu, Dongge
2015-08-01
To evaluate the Ventana IHC ALK (D5F3) assay for detecting anaplastic lymphoma kinase (ALK) protein expression in pleural effusion samples. Historical, selected (wild-type EGFR, K-RAS) pleural effusion cytologic blocks of lung adenocarcinoma samples (Study 1) and unselected lung adenocarcinoma pleural effusion cytologic blocks (Study 2) were tested by Ventana IHC ALK (D5F3) assay. Quantitative real-time-PCR was used to verify immunohistochemistry results. A total of 17 out of 100 (Study 1) and ten out of 104 (Study 2) pleural effusion samples were ALK expression positive by the Ventana IHC ALK (D5F3) assay. The ALK fusion results with immunohistochemistry and quantitative real-time-PCR had a concordance rate of 87.5% (κ = 0.886; p < 0.001). The Ventana IHC ALK (D5F3) assay is a reliable tool for detecting ALK protein expression in pleural effusion samples.
Enhancing Time-Series Detection Algorithms for Automated Biosurveillance
Burkom, Howard; Xing, Jian; English, Roseanne; Bloom, Steven; Cox, Kenneth; Pavlin, Julie A.
2009-01-01
BioSense is a US national system that uses data from health information systems for automated disease surveillance. We studied 4 time-series algorithm modifications designed to improve sensitivity for detecting artificially added data. To test these modified algorithms, we used reports of daily syndrome visits from 308 Department of Defense (DoD) facilities and 340 hospital emergency departments (EDs). At a constant alert rate of 1%, sensitivity was improved for both datasets by using a minimum standard deviation (SD) of 1.0, a 14–28 day baseline duration for calculating mean and SD, and an adjustment for total clinic visits as a surrogate denominator. Stratifying baseline days into weekdays versus weekends to account for day-of-week effects increased sensitivity for the DoD data but not for the ED data. These enhanced methods may increase sensitivity without increasing the alert rate and may improve the ability to detect outbreaks by using automated surveillance system data. PMID:19331728
Kelly, Brian P.
2011-01-01
The City of Independence, Missouri, operates a well field in the Missouri River alluvial aquifer. Contributing recharge areas (CRA) were last determined for the well field in 1996. Since that time, eight supply wells have been installed in the area north of the Missouri River and well pumpage has changed for the older supply wells. The change in pumping has altered groundwater flow and substantially changed the character of the CRA and groundwater travel times to the supply wells. The U.S Geological Survey, in a cooperative study with the City of Independence, Missouri, simulated steady-state groundwater flow for 2007 well pumpage, average annual river stage, and average annual recharge. Particle-tracking analysis was used to determine the CRA for supply wells and monitoring wells, and the travel time from recharge areas to supply wells, recharge areas to monitoring wells, and monitoring wells to supply wells. The simulated CRA for the well field is elongated in the upstream direction and extends to both sides of the Missouri River. Groundwater flow paths and recharge areas estimated for monitoring wells indicate the origin of water to each monitoring well, the travel time of that water from the recharge area, the flow path from the vicinity of each monitoring well to a supply well, and the travel time from the monitoring well to the supply well. Monitoring wells 14a and 14b have the shortest groundwater travel time from their contributing recharge area of 0.30 years and monitoring well 29a has the longest maximum groundwater travel time from its contributing recharge area of 1,701 years. Monitoring well 22a has the shortest groundwater travel time of 0.5 day to supply well 44 and monitoring well 3b has the longest maximum travel time of 31.91 years to supply well 10. Water-quality samples from the Independence groundwater monitoring well network were collected from 1997 to 2008 by USGS personnel during ongoing annual sampling within the 10-year contributing recharge area (CRA) of the Independence well field. Statistical summaries and the spatial and temporal variability of water quality in the Missouri River alluvial aquifer near the Independence well field were characterized from analyses of 598 water samples. Water-quality constituent groups include dissolved oxygen and physical properties, nutrients, major ions and trace elements, wastewater indicator compounds, fuel compounds, and total benzene, toluene, ethylbenzene, and xylene (BTEX), alachlor, and atrazine. The Missouri Secondary Maximum Contaminant Level (SMCL) for iron was exceeded in almost all monitoring wells. The Missouri Maximum Contaminant Level (MCL) for arsenic was exceeded 32 times in samples from monitoring wells. The MCL for barium was exceeded five times in samples from one monitoring well. The SMCL for manganese was exceeded 160 times in samples from all monitoring wells and the combined well-field sample. The most frequently detected wastewater indicator compounds were N,N-diethyl-meta-toluamide (DEET), phenol, caffeine, and metolachlor. The most frequently detected fuel compounds were toluene and benzene. Alachlor was detected in 22 samples and atrazine was detected in 37 samples and the combined well-field sample. The MCL for atrazine was exceeded in one sample from one monitoring well. Samples from monitoring wells with median concentrations of total inorganic nitrogen larger than 1 milligram per liter (mg/L) are located near agricultural land and may indicate that agricultural land practices are the source of nitrogen to groundwater. Largest median values of specific conductance; total inorganic nitrogen; dissolved calcium, magnesium, sodium, iron, arsenic, manganese, bicarbonate, and sulfate and detections of wastewater indicator compounds generally were in water samples from monitoring wells with CRAs that intersect the south bank of the Missouri River. Zones of higher specific conductance were located just upstream from the Independen
Xue, Yong; Wilkes, Jon G.; Moskal, Ted J.; Williams, Anna J.; Cooper, Willie M.; Nayak, Rajesh; Rafii, Fatemeh; Buzatu, Dan A.
2016-01-01
Standard methods to detect Escherichia coli contamination in food use the polymerase chain reaction (PCR) and agar culture plates. These methods require multiple incubation steps and take a long time to results. An improved rapid flow-cytometry based detection method was developed, using a fluorescence-labeled oligonucleotide probe specifically binding a16S rRNA sequence. The method positively detected 51 E. coli isolates as well as 4 Shigella species. All 27 non-E. coli strains tested gave negative results. Comparison of the new genetic assay with a total plate count (TPC) assay and agar plate counting indicated similar sensitivity, agreement between cytometry cell and colony counts. This method can detect a small number of E.coli cells in the presence of large numbers of other bacteria. This method can be used for rapid, economical, and stable detection of E. coli and Shigella contamination in the food industry and other contexts. PMID:26913737
Xue, Yong; Wilkes, Jon G; Moskal, Ted J; Williams, Anna J; Cooper, Willie M; Nayak, Rajesh; Rafii, Fatemeh; Buzatu, Dan A
2016-01-01
Standard methods to detect Escherichia coli contamination in food use the polymerase chain reaction (PCR) and agar culture plates. These methods require multiple incubation steps and take a long time to results. An improved rapid flow-cytometry based detection method was developed, using a fluorescence-labeled oligonucleotide probe specifically binding a16S rRNA sequence. The method positively detected 51 E. coli isolates as well as 4 Shigella species. All 27 non-E. coli strains tested gave negative results. Comparison of the new genetic assay with a total plate count (TPC) assay and agar plate counting indicated similar sensitivity, agreement between cytometry cell and colony counts. This method can detect a small number of E.coli cells in the presence of large numbers of other bacteria. This method can be used for rapid, economical, and stable detection of E. coli and Shigella contamination in the food industry and other contexts.
An Improved Harmonic Current Detection Method Based on Parallel Active Power Filter
NASA Astrophysics Data System (ADS)
Zeng, Zhiwu; Xie, Yunxiang; Wang, Yingpin; Guan, Yuanpeng; Li, Lanfang; Zhang, Xiaoyu
2017-05-01
Harmonic detection technology plays an important role in the applications of active power filter. The accuracy and real-time performance of harmonic detection are the precondition to ensure the compensation performance of Active Power Filter (APF). This paper proposed an improved instantaneous reactive power harmonic current detection algorithm. The algorithm uses an improved ip -iq algorithm which is combined with the moving average value filter. The proposed ip -iq algorithm can remove the αβ and dq coordinate transformation, decreasing the cost of calculation, simplifying the extraction process of fundamental components of load currents, and improving the detection speed. The traditional low-pass filter is replaced by the moving average filter, detecting the harmonic currents more precisely and quickly. Compared with the traditional algorithm, the THD (Total Harmonic Distortion) of the grid currents is reduced from 4.41% to 3.89% for the simulations and from 8.50% to 4.37% for the experiments after the improvement. The results show the proposed algorithm is more accurate and efficient.
Evaluation of Polymerase Chain Reaction for Detecting Coliform Bacteria in Drinking Water Sources.
Isfahani, Bahram Nasr; Fazeli, Hossein; Babaie, Zeinab; Poursina, Farkhondeh; Moghim, Sharareh; Rouzbahani, Meisam
2017-01-01
Coliform bacteria are used as indicator organisms for detecting fecal pollution in water. Traditional methods including microbial culture tests in lactose-containing media and enzyme-based tests for the detection of β-galactosidase; however, these methods are time-consuming and less specific. The aim of this study was to evaluate polymerase chain reaction (PCR) for detecting coliform. Totally, 100 of water samples from Isfahan drinking water source were collected. Coliform bacteria and Escherichia coli were detected in drinking water using LacZ and LamB genes in PCR method performed in comparison with biochemical tests for all samples. Using phenotyping, 80 coliform isolates were found. The results of the biochemical tests illustrated 78.7% coliform bacteria and 21.2% E. coli . PCR results for LacZ and LamB genes were 67.5% and 17.5%, respectively. The PCR method was shown to be an effective, sensitive, and rapid method for detecting coliform and E. coli in drinking water from the Isfahan drinking water sources.
Electrochemical detection of microRNAs via gap hybridization assay.
Pöhlmann, Christopher; Sprinzl, Mathias
2010-06-01
MicroRNAs have recently been associated with cancer development by acting as tumor suppressors or oncogenes and could therefore be applied as molecular markers for early diagnosis of cancer. In this work, we established a rapid, selective, and sensitive gap hybridization assay for detection of mature microRNAs based on four components DNA/RNA hybridization and electrochemical detection using esterase 2-oligodeoxynucleotide conjugates. Complementary binding of microRNA to a gap built of capture and detector oligodeoxynucleotide, the reporter enzyme is brought to the vicinity of the electrode and produces enzymatically an electrochemical signal. In the absence of microRNA, the gap between capture and detector oligodeoxynucleotide is not filled, and missing base stacking energy destabilizes the hybridization complex. The gap hybridization assay demonstrates selective detection of miR-16 within a mixture of other miRNAs, including the feasibility of single mismatch discrimination. Applying the biosensor assay, a detection limit of 2 pM or 2 amol of miR-16 was obtained. Using isolated total RNA from human breast adenocarcinoma MCF-7 cells, the assay detected specifically miR-21 and miR-16 in parallel, and higher expression of oncogene miR-21 compared to miR-16 was demonstrated. Including RNA isolation, the gap hybridization assay was developed with a total assay time of 60 min and without the need for reverse transcription PCR amplification of the sample. The characteristics of the assay developed in this work could satisfy the need for rapid and easy methods for early cancer marker detection in clinical diagnostics.
Henriksen, Emilie L; Carlsen, Jonathan F; Vejborg, Ilse Mm; Nielsen, Michael B; Lauridsen, Carsten A
2018-01-01
Background Early detection of breast cancer (BC) is crucial in lowering the mortality. Purpose To present an overview of studies concerning computer-aided detection (CAD) in screening mammography for early detection of BC and compare diagnostic accuracy and recall rates (RR) of single reading (SR) with SR + CAD and double reading (DR) with SR + CAD. Material and Methods PRISMA guidelines were used as a review protocol. Articles on clinical trials concerning CAD for detection of BC in a screening population were included. The literature search resulted in 1522 records. A total of 1491 records were excluded by abstract and 18 were excluded by full text reading. A total of 13 articles were included. Results All but two studies from the SR vs. SR + CAD group showed an increased sensitivity and/or cancer detection rate (CDR) when adding CAD. The DR vs. SR + CAD group showed no significant differences in sensitivity and CDR. Adding CAD to SR increased the RR and decreased the specificity in all but one study. For the DR vs. SR + CAD group only one study reported a significant difference in RR. Conclusion All but two studies showed an increase in RR, sensitivity and CDR when adding CAD to SR. Compared to DR no statistically significant differences in sensitivity or CDR were reported. Additional studies based on organized population-based screening programs, with longer follow-up time, high-volume readers, and digital mammography are needed to evaluate the efficacy of CAD.
Choudhary, Nandlal; Wei, G; Govindarajulu, A; Roy, Avijit; Li, Wenbin; Picton, Deric D; Nakhla, M K; Levy, L; Brlansky, R H
2015-11-01
Citrus leprosis virus C (CiLV-C), a causal agent of the leprosis disease in citrus, is mostly present in the South and Central America and spreading toward the North America. To enable better diagnosis and inhibit the further spread of this re-emerging virus a quantitative (q) real-time reverse transcription polymerase chain reaction (qRT-PCR) assay is needed for early detection of CiLV-C when the virus is present in low titer in citrus leprosis samples. Using the genomic sequence of CiLV-C, specific primers and probe were designed and synthesized to amplify a 73 nt amplicon from the movement protein (MP) gene. A standard curve of the 73 nt amplicon MP gene was developed using known 10(10)-10(1) copies of in vitro synthesized RNA transcript to estimate the copy number of RNA transcript in the citrus leprosis samples. The one-step qRT-PCR detection assays for CiLV-C were determined to be 1000 times more sensitive when compared to the one-step conventional reverse transcription polymerase chain reaction (RT-PCR) CiLV-C detection method. To evaluate the quality of the total RNA extracts, NADH dehydrogenase gene specific primers (nad5) and probe were included in reactions as an internal control. The one-step qRT-PCR specificity was successfully validated by testing for the presence of CiLV-C in the total RNA extracts of the citrus leprosis samples collected from Belize, Costa Rica, Mexico and Panama. Implementation of the one-step qRT-PCR assays for CiLV-C diagnosis should assist regulatory agencies in surveillance activities to monitor the distribution pattern of CiLV-C in countries where it is present and to prevent further dissemination into citrus growing countries where there is no report of CiLV-C presence. Published by Elsevier B.V.
Xu, Wei; Chen, Deying; Wang, Nan; Zhang, Ting; Zhou, Ruokun; Huan, Tao; Lu, Yingfeng; Su, Xiaoling; Xie, Qing; Li, Liang; Li, Lanjuan
2015-01-20
Human fecal samples contain endogenous human metabolites, gut microbiota metabolites, and other compounds. Profiling the fecal metabolome can produce metabolic information that may be used not only for disease biomarker discovery, but also for providing an insight about the relationship of the gut microbiome and human health. In this work, we report a chemical isotope labeling liquid chromatography-mass spectrometry (LC-MS) method for comprehensive and quantitative analysis of the amine- and phenol-containing metabolites in fecal samples. Differential (13)C2/(12)C2-dansyl labeling of the amines and phenols was used to improve LC separation efficiency and MS detection sensitivity. Water, methanol, and acetonitrile were examined as an extraction solvent, and a sequential water-acetonitrile extraction method was found to be optimal. A step-gradient LC-UV setup and a fast LC-MS method were evaluated for measuring the total concentration of dansyl labeled metabolites that could be used for normalizing the sample amounts of individual samples for quantitative metabolomics. Knowing the total concentration was also useful for optimizing the sample injection amount into LC-MS to maximize the number of metabolites detectable while avoiding sample overloading. For the first time, dansylation isotope labeling LC-MS was performed in a simple time-of-flight mass spectrometer, instead of high-end equipment, demonstrating the feasibility of using a low-cost instrument for chemical isotope labeling metabolomics. The developed method was applied for profiling the amine/phenol submetabolome of fecal samples collected from three families. An average of 1785 peak pairs or putative metabolites were found from a 30 min LC-MS run. From 243 LC-MS runs of all the fecal samples, a total of 6200 peak pairs were detected. Among them, 67 could be positively identified based on the mass and retention time match to a dansyl standard library, while 581 and 3197 peak pairs could be putatively identified based on mass match using MyCompoundID against a Human Metabolome Database and an Evidence-based Metabolome Library, respectively. This represents the most comprehensive profile of the amine/phenol submetabolome ever detected in human fecal samples. The quantitative metabolome profiles of individual samples were shown to be useful to separate different groups of samples, illustrating the possibility of using this method for fecal metabolomics studies.
Barker, Z E; Vázquez Diosdado, J A; Codling, E A; Bell, N J; Hodges, H R; Croft, D P; Amory, J R
2018-04-25
Time constraints for dairy farmers are an important factor contributing to the under-detection of lameness, resulting in delayed or missed treatment of lame cows within many commercial dairy herds. Hence, a need exists for flexible and affordable cow-based sensor systems capable of monitoring behaviors such as time spent feeding, which may be affected by the onset of lameness. In this study a novel neck-mounted mobile sensor system that combines local positioning and activity (acceleration) was tested and validated on a commercial UK dairy farm. Position and activity data were collected over 5 consecutive days for 19 high-yield dairy cows (10 lame, 9 nonlame) that formed a subset of a larger (120 cow) management group housed in a freestall barn. A decision tree algorithm that included sensor-recorded position and accelerometer data was developed to classify a cow as doing 1 of 3 categories of behavior: (1) feeding, (2) not feeding, and (3) out of pen for milking. For each classified behavior the mean number of bouts, the mean bout duration, and the mean total duration across all bouts was determined on a daily basis, and also separately for the time periods in between milking (morning = 0630-1300 h; afternoon = 1430-2100 h; night = 2230-0500 h). A comparative analysis of the classified cow behaviors was undertaken using a Welch t-test with Benjamini-Hochberg post-hoc correction under the null hypothesis of no differences in the number or duration of behavioral bouts between the 2 test groups of lame and nonlame cows. Analysis showed that mean total daily feeding duration was significantly lower for lame cows compared with non-lame cows. Behavior was also affected by time of day with significantly lower mean total duration of feeding and higher total duration of nonfeeding in the afternoons for lame cows compared with nonlame cows. The results demonstrate how sensors that measure both position and acceleration are capable of detecting differences in feeding behavior that may be associated with lameness. Such behavioral differences could be used in the development of predictive algorithms for the prompt detection of lameness as part of a commercially viable automated behavioral monitoring system. The Authors. Published by FASS Inc. and Elsevier Inc. on behalf of the American Dairy Science Association®. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
Monitoring tropical forest degradation using time series analysis of Landsat and Sentinel-2 data
NASA Astrophysics Data System (ADS)
Bullock, E.; Woodcock, C. E.
2017-12-01
Tropical forest loss is expected to be contribute 5 to 15% of anthropogenic carbon emissions in the coming century. The wide range of expected emissions is indicative of the large uncertainties that exist in the terrestrial carbon cycle. Total carbon loss from forest conversion consists of loss from deforestation plus loss from degradation. There have been significant improvements in the ability to relate plot-level estimates of carbon stocks to remote sensing-derived calculations of deforestation to estimate total carbon emissions from forest loss. These approaches, however, have been limited in their ability to assess the magnitude, extent, and overall impact of forest degradation. The causes of tropical degradation include selective logging, fuel wood collection, fires, and the development of forest plantations. This study demonstrates a newly developed methodology for detecting subtle changes in forest structure and condition using time series analysis of Landsat and Sentinel-2 data. The research shows how the ability to detect small changes in forest biomass, in addition to changes in forest composition, can be improved by incorporating historical context and multi-sensor data fusion. Results are demonstrated from two climatically unique tropical forests in Thailand and Brazil.
Monitoring early tumor response to drug therapy with diffuse optical tomography
NASA Astrophysics Data System (ADS)
Flexman, Molly L.; Vlachos, Fotios; Kim, Hyun Keol; Sirsi, Shashank R.; Huang, Jianzhong; Hernandez, Sonia L.; Johung, Tessa B.; Gander, Jeffrey W.; Reichstein, Ari R.; Lampl, Brooke S.; Wang, Antai; Borden, Mark A.; Yamashiro, Darrell J.; Kandel, Jessica J.; Hielscher, Andreas H.
2012-01-01
Although anti-angiogenic agents have shown promise as cancer therapeutics, their efficacy varies between tumor types and individual patients. Providing patient-specific metrics through rapid noninvasive imaging can help tailor drug treatment by optimizing dosages, timing of drug cycles, and duration of therapy--thereby reducing toxicity and cost and improving patient outcome. Diffuse optical tomography (DOT) is a noninvasive three-dimensional imaging modality that has been shown to capture physiologic changes in tumors through visualization of oxygenated, deoxygenated, and total hemoglobin concentrations, using non-ionizing radiation with near-infrared light. We employed a small animal model to ascertain if tumor response to bevacizumab (BV), an anti-angiogenic agent that targets vascular endothelial growth factor (VEGF), could be detected at early time points using DOT. We detected a significant decrease in total hemoglobin levels as soon as one day after BV treatment in responder xenograft tumors (SK-NEP-1), but not in SK-NEP-1 control tumors or in non-responder control or BV-treated NGP tumors. These results are confirmed by magnetic resonance imaging T2 relaxometry and lectin perfusion studies. Noninvasive DOT imaging may allow for earlier and more effective control of anti-angiogenic therapy.
3D registration of surfaces for change detection in medical images
NASA Astrophysics Data System (ADS)
Fisher, Elizabeth; van der Stelt, Paul F.; Dunn, Stanley M.
1997-04-01
Spatial registration of data sets is essential for quantifying changes that take place over time in cases where the position of a patient with respect to the sensor has been altered. Changes within the region of interest can be problematic for automatic methods of registration. This research addresses the problem of automatic 3D registration of surfaces derived from serial, single-modality images for the purpose of quantifying changes over time. The registration algorithm utilizes motion-invariant, curvature- based geometric properties to derive an approximation to an initial rigid transformation to align two image sets. Following the initial registration, changed portions of the surface are detected and excluded before refining the transformation parameters. The performance of the algorithm was tested using simulation experiments. To quantitatively assess the registration, random noise at various levels, known rigid motion transformations, and analytically-defined volume changes were applied to the initial surface data acquired from models of teeth. These simulation experiments demonstrated that the calculated transformation parameters were accurate to within 1.2 percent of the total applied rotation and 2.9 percent of the total applied translation, even at the highest applied noise levels and simulated wear values.
Vera-Jimenez, N I; Pietretti, D; Wiegertjes, G F; Nielsen, M E
2013-05-01
The respiratory burst is an important feature of the immune system. The increase in cellular oxygen uptake that marks the initiation of the respiratory burst is followed by the production of reactive oxygen species (ROS) such as superoxide anion and hydrogen peroxide which plays a role in the clearance of pathogens and tissue regeneration processes. Therefore, the respiratory burst and associated ROS constitute important indicators of fish health status. This paper compares two methods for quantitation of ROS produced during the respiratory burst in common carp: the widely used, single-point measurement based on the intracellular reduction of nitroblue tetrazolium (NBT) and a real-time luminol-enhanced assay based on the detection of native chemiluminescence. Both assays allowed for detection of dose-dependent changes in magnitude of the respiratory burst response induced by β-glucans in head kidney cells of carp. However, whereas the NBT assay was shown to detect the production of only superoxide anions, the real-time luminol-enhanced assay could detect the production of both superoxide anions and hydrogen peroxide. Only the chemiluminescence assay could reliably record the production of ROS on a real-time scale at frequent and continual time intervals for time course experiments, providing more detailed information on the respiratory burst response. The real-time chemiluminescence assay was used to measure respiratory burst activity in macrophage and neutrophilic granulocyte-enriched head kidney cell fractions and total head kidney cell suspensions and proved to be a fast, reliable, automated multiwell microplate assay to quantitate fish health status modulated by β-glucans. Copyright © 2013 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinenghi, E., E-mail: edoardo.martinenghi@polimi.it; Di Sieno, L.; Contini, D.
2016-07-15
We present the design and preliminary characterization of the first detection module based on Silicon Photomultiplier (SiPM) tailored for single-photon timing applications. The aim of this work is to demonstrate, thanks to the design of a suitable module, the possibility to easily exploit SiPM in many applications as an interesting detector featuring large active area, similarly to photomultipliers tubes, but keeping the advantages of solid state detectors (high quantum efficiency, low cost, compactness, robustness, low bias voltage, and insensitiveness to magnetic field). The module integrates a cooled SiPM with a total photosensitive area of 1 mm{sup 2} together with themore » suitable avalanche signal read-out circuit, the signal conditioning, the biasing electronics, and a Peltier cooler driver for thermal stabilization. It is able to extract the single-photon timing information with resolution better than 100 ps full-width at half maximum. We verified the effective stabilization in response to external thermal perturbations, thus proving the complete insensitivity of the module to environment temperature variations, which represents a fundamental parameter to profitably use the instrument for real-field applications. We also characterized the single-photon timing resolution, the background noise due to both primary dark count generation and afterpulsing, the single-photon detection efficiency, and the instrument response function shape. The proposed module can become a reliable and cost-effective building block for time-correlated single-photon counting instruments in applications requiring high collection capability of isotropic light and detection efficiency (e.g., fluorescence decay measurements or time-domain diffuse optics systems).« less
Besmer, Michael D.; Sigrist, Jürg A.; Props, Ruben; Buysschaert, Benjamin; Mao, Guannan; Boon, Nico; Hammes, Frederik
2017-01-01
Rapid contamination of drinking water in distribution and storage systems can occur due to pressure drop, backflow, cross-connections, accidents, and bio-terrorism. Small volumes of a concentrated contaminant (e.g., wastewater) can contaminate large volumes of water in a very short time with potentially severe negative health impacts. The technical limitations of conventional, cultivation-based microbial detection methods neither allow for timely detection of such contaminations, nor for the real-time monitoring of subsequent emergency remediation measures (e.g., shock-chlorination). Here we applied a newly developed continuous, ultra high-frequency flow cytometry approach to track a rapid pollution event and subsequent disinfection of drinking water in an 80-min laboratory scale simulation. We quantified total (TCC) and intact (ICC) cell concentrations as well as flow cytometric fingerprints in parallel in real-time with two different staining methods. The ingress of wastewater was detectable almost immediately (i.e., after 0.6% volume change), significantly changing TCC, ICC, and the flow cytometric fingerprint. Shock chlorination was rapid and detected in real time, causing membrane damage in the vast majority of bacteria (i.e., drop of ICC from more than 380 cells μl-1 to less than 30 cells μl-1 within 4 min). Both of these effects as well as the final wash-in of fresh tap water followed calculated predictions well. Detailed and highly quantitative tracking of microbial dynamics at very short time scales and for different characteristics (e.g., concentration, membrane integrity) is feasible. This opens up multiple possibilities for targeted investigation of a myriad of bacterial short-term dynamics (e.g., disinfection, growth, detachment, operational changes) both in laboratory-scale research and full-scale system investigations in practice. PMID:29085343
NASA Technical Reports Server (NTRS)
Hodanish, S; Sharp, D.; Williams, E.; Boldi, B.; Goodman, Steven J.; Raghavan, R.; Matlin, A.; Weber, M.
1998-01-01
During the early morning hours of February 23 1998, the worst tornado outbreak ever recorded occurred over the central Florida peninsula. At least 7 confirmed tornadoes, associated with 4 supercells, developed, with 3 of the tornadoes reaching F3 intensity. Many of the tornadoes where on the ground for tens of miles, uncommon for the state of Florida. A total of 42 people were killed, with over 250 people injured. During the outbreak, National Weather Service Melbourne, in collaboration with the National Aeronautics and Space Administration and the Massachusetts Institute of Technology was collecting data from a unique lightning observing system called Lightning Imaging Sensor Data Applications Display (LISDAD, Boldi et.al., this conference). This system marries radar data collected from the KMLB WSR-88D, cloud to ground data collected from the National Lightning Detection Network, and total lightning data collected from NASKs Lightning Detection And Ranging system. This poster will display, concurrently, total lightning data (displayed in 1 minute increments), time/height storm relative velocity products from the KMLB WSR-88D, and damage information (tornado/hail/wind) from each of the supercell thunderstorms. The primary objective of this poster presentation is to observe how total lightning activity changes as the convective storm intensifies, and how the lightning activity changes with respect to mesocyclone strength (vortex stretching) and damaging weather on the ground.
Bierla, Katarzyna; Flis-Borsuk, Anna; Suchocki, Piotr; Szpunar, Joanna; Lobinski, Ryszard
2016-06-22
The reaction of sunflower oil with selenite produces a complex mixture of selenitriglycerides with antioxidant and anticancer properties. To obtain insight into the identity and characteristics of the species formed, an analytical approach based on the combination of high-performance liquid chromatography (HPLC) with (78)Se-specific selenium detection by inductively coupled plasma mass spectrometry (ICP MS) and high-resolution (100 000), high mass accuracy (<1 ppm) molecule-specific detection by electrospray-Orbitrap MS(3) was developed. For the first time, a non-aqueous mobile phase gradient was used in reversed-phase HPLC-ICP MS for the separation of a complex mixture of selenospecies and a mathematical correction of the background signal was developed. The identical chromatographic conditions served for the sample introduction into electrospray MS. Two types of samples were analyzed: sunflower oil dissolved in isopropanol and methanol extract of the oil containing 65% selenium. HPLC-ICP MS showed 14 peaks, 11 of which could also be detected in the methanol extract. Isotopic patterns corresponding to molecules with one or two selenium atoms could be attributed by Orbitrap MS at the retention times corresponding to the HPLC-ICP MS peak apexes. Structural data for these species were acquired by MS(2) and MS(3) fragmentation of protonated or sodiated ions using high-energy collisional dissociation (HCD). A total of 11 selenium-containing triglycerol derivatives resulting from the oxidation of one or two double bonds of linoleic acid and analogous derivatives of glycerol-mixed linoleate(s)/oleinate(s) have been identified for the first time. The presence of these species was confirmed by the targeted analysis in the total oil isopropanol solution. Their identification corroborated the predicted elution order in reversed-phase chromatography: LLL (glycerol trilinoleate), LLO (glycerol dilinoleate-oleinate), LOO (glycerol linoleate-dioleinate), OOO (glycerol trioleinate), of which the extrapolation allowed for the prediction of the identity [glycerol dioleinate-stearate (OOS) and glycerol oleinate-distearate (OSS)] of the nonpolar species detected by ICP MS in the oil but not detected by electrospray MS.
Kim, Hyunwoo; Cha, Go-Woon; Jeong, Young Eui; Lee, Wook-Gyo; Chang, Kyu Sik; Roh, Jong Yul; Yang, Sung Chan; Park, Mi Yeoun; Park, Chan; Shin, E-Hyun
2015-01-01
Japanese encephalitis virus (JEV) causes significant viral encephalitis and is distributed throughout the Asian countries. The virus is known to be transmitted by Culex tritaeniorhynchus, which mainly breeds in rice paddies in Korea. In this study, we investigated the presence of other mosquito species that can transmit JEV as a second or regional vector. We selected five cities where patients have experienced JE in the last 5 years as mosquito-collecting locations and subdivided them into four collection sites according to the mosquito habitats (cowshed, downtown area, forest, and swamp). Mosquitoes were caught using the BG-Sentinel trap, CDC black-light trap, Fay-Prince trap, and Gravid trap. A total of 993 pools from 22,774 mosquitoes were prepared according to their species, collection date, and site. We performed a SYBR Green 1-based real-time RT-PCR assay to detect JEV from the mosquito pools. A total of six JEV-positive pools were detected from Culex orientalis and Culex pipiens caught in the Gangwon-do and Gyeonngi-do provinces. All the detected JEVs were revealed as genotype V by phylogenetic analysis of the envelope gene. Our findings confirm that a new genotype of JEV was introduced in Korea and suggest that two mosquito species may play a role in JEV transmission.
Mark-resight superpopulation estimation of a wintering elk Cervus elaphus canadensis herd
Gould, W.R.; Smallidge, S.T.; Thompson, B.C.
2005-01-01
We executed four mark-resight helicopter surveys during the winter months January-February for each of the three years 1999-2001 at 7-10 day intervals to estimate population size of a wintering elk Cervus elaphus canadensis herd in northern New Mexico. We counted numbers of radio-collared and uncollared elk on a simple random sample of quadrats from the study area. Because we were unable to survey the entire study area, we adopted a superpopulation approach to estimating population size, in which the total number of collared animals within and proximate to the entire study area was determined from an independent fixed-wing aircraft. The total number of collared animals available on the quadrats surveyed was also determined and facilitated detectability estimation. We executed superpopulation estimation via the joint hypergeometric estimator using the ratio of marked elk counted to the known number extant as an estimate of effective detectability. Superpopulation size estimates were approximately four times larger than previously suspected in the vicinity of the study area. Despite consistent survey methodology, actual detection rates varied within winter periods, indicating that multiple resight flights are important for improved estimator performance. Variable detectability also suggests that reliance on mere counts of observed individuals in our area may not accurately reflect abundance. ?? Wildlife Biology (2005).
Support vector machines for TEC seismo-ionospheric anomalies detection
NASA Astrophysics Data System (ADS)
Akhoondzadeh, M.
2013-02-01
Using time series prediction methods, it is possible to pursue the behaviors of earthquake precursors in the future and to announce early warnings when the differences between the predicted value and the observed value exceed the predefined threshold value. Support Vector Machines (SVMs) are widely used due to their many advantages for classification and regression tasks. This study is concerned with investigating the Total Electron Content (TEC) time series by using a SVM to detect seismo-ionospheric anomalous variations induced by the three powerful earthquakes of Tohoku (11 March 2011), Haiti (12 January 2010) and Samoa (29 September 2009). The duration of TEC time series dataset is 49, 46 and 71 days, for Tohoku, Haiti and Samoa earthquakes, respectively, with each at time resolution of 2 h. In the case of Tohoku earthquake, the results show that the difference between the predicted value obtained from the SVM method and the observed value reaches the maximum value (i.e., 129.31 TECU) at earthquake time in a period of high geomagnetic activities. The SVM method detected a considerable number of anomalous occurrences 1 and 2 days prior to the Haiti earthquake and also 1 and 5 days before the Samoa earthquake in a period of low geomagnetic activities. In order to show that the method is acting sensibly with regard to the results extracted during nonevent and event TEC data, i.e., to perform some null-hypothesis tests in which the methods would also be calibrated, the same period of data from the previous year of the Samoa earthquake date has been taken into the account. Further to this, in this study, the detected TEC anomalies using the SVM method were compared to the previous results (Akhoondzadeh and Saradjian, 2011; Akhoondzadeh, 2012) obtained from the mean, median, wavelet and Kalman filter methods. The SVM detected anomalies are similar to those detected using the previous methods. It can be concluded that SVM can be a suitable learning method to detect the novelty changes of a nonlinear time series such as variations of earthquake precursors.
Can JWST Follow Up on Gravitational-Wave Detections?
NASA Astrophysics Data System (ADS)
Kohler, Susanna
2016-02-01
Bitten by the gravitational-wave bug? While we await Thursdays press conference, heres some food for thought: if LIGO were able to detect gravitational waves from compact-object mergers, how could we follow up on the detections? A new study investigates whether the upcoming James Webb Space Telescope (JWST) will be able to observe electromagnetic signatures of some compact-object mergers.Hunting for MergersStudying compact-object mergers (mergers of black holes and neutron stars) can help us understand a wealth of subjects, like high-energy physics, how matter behaves at nuclear densities, how stars evolve, and how heavy elements in the universe were created.The Laser Interferometer Gravitational-Wave Observatory (LIGO) is searching for the signature ripples in spacetime identifying these mergers, but gravitational waves are squirrelly: LIGO will only be able to localize wave sources to tens of square degrees. If we want to find out more about any mergers LIGO discovers in gravitational waves, well need a follow-up search for electromagnetic counterparts with other observatories.The Kilonova KeyOne possible electromagnetic counterpart is kilonovae, explosions that can be produced during a merger of a binary neutron star or a neutron starblack hole system. If the neutron star is disrupted during the merger, some of the hot mass is flung outward and shines brightly by radioactive decay.Kilonovae are especially promising as electromagnetic counterparts to gravitational waves for three reasons:They emit isotropically, so the number of observable mergers isnt limited by relativistic beaming.They shine for a week, giving follow-up observatories time to search for them.The source location can beeasily recovered.The only problem? We dont currently have any sensitive survey instruments in the near-infrared band (where kilonova emission peaks) that can provide coverage over tens of square degrees. Luckily, we will soon have just the thing: JWST, launching in 2018!JWSTs SearchIntegration time needed for JWSTs NIRCam to detect a kilonova at 200 Mpc, as a function of time since the merger. Different curves correspond to different NIRCam filters. Note that the total time for follow-up is overwhelmingly dominated by things like telescope slew time, rather than by this exposure time. [Bartos et al. 2016]In a recent study, a team of authors led by Imre Bartos (Columbia University) evaluatewhether JWST will be capable of catching these kilonovae if LIGO finds gravitational wave signals.Bartos and collaborators calculate that, given the sensitivity of the different filters on JWSTs Near-Infrared Camera, the instrument should easily be able to detect a kilonova 200 Mpc away (a typical distance at which LIGO might be able to find a neutron-star binary). But theres a catch: 10 deg2 is a really big sky area, and it would take JWST an unfeasible amount of time (days!) to fully cover it.The authors suggest insteadusing a targeted search. Since most mergers are expected to be in or near galaxies, JWST could specifically focus the follow-up search on known galaxies within the searcharea. This approach would bring the total search time down to 12.6 hours, which is within the realm of feasibility. And this time could be reduced even further by concentrating on galaxies most likely to host kilonovae, like those with high star-formation rates.The conclusion: if LIGO is able to detect gravitational waves, JWST will provide an excellent means to follow up on the detection in the attempt toidentify the source.CitationI. Bartos et al 2016 ApJ 816 61. doi:10.3847/0004-637X/816/2/61
Ma, Qi; Yang, Dong-Rong; Xue, Bo-Xin; Wang, Cheng; Chen, Han-Bin; Dong, Yun; Wang, Cai-Shan; Shan, Yu-Xi
2017-07-01
The focus of the present study was to evaluate transrectal real-time tissue elastography (RTE)-targeted two-core biopsy coupled with peak strain index for the detection of prostate cancer (PCa) and to compare this method with 10-core systematic biopsy. A total of 141 patients were enrolled for evaluation. The diagnostic value of peak strain index was assessed using a receiver operating characteristic curve. The cancer detection rates of the two approaches and corresponding positive cores and Gleason score were compared. The cancer detection rate per core in the RTE-targeted biopsy (44%) was higher compared with that in systematic biopsy (30%). The peak strain index value of PCa was higher compared with that of the benign lesion. PCa was detected with the highest sensitivity (87.5%) and specificity (85.5%) using the threshold value of a peak strain index of ≥5.97 with an area under the curve value of 0.95. When the Gleason score was ≥7, RTE-targeted biopsy coupled with peak strain index detected 95.6% of PCa cases, but 84.4% were detected using systematic biopsy. Peak strain index as a quantitative parameter may improve the differentiation of PCa from benign lesions in the prostate peripheral zone. Transrectal RTE-targeted biopsy coupled with peak strain index may enhance the detection of clinically significant PCa, particularly when combined with systematic biopsy.
Learning to Detect Vandalism in Social Content Systems: A Study on Wikipedia
NASA Astrophysics Data System (ADS)
Javanmardi, Sara; McDonald, David W.; Caruana, Rich; Forouzan, Sholeh; Lopes, Cristina V.
A challenge facing user generated content systems is vandalism, i.e. edits that damage content quality. The high visibility and easy access to social networks makes them popular targets for vandals. Detecting and removing vandalism is critical for these user generated content systems. Because vandalism can take many forms, there are many different kinds of features that are potentially useful for detecting it. The complex nature of vandalism, and the large number of potential features, make vandalism detection difficult and time consuming for human editors. Machine learning techniques hold promise for developing accurate, tunable, and maintainable models that can be incorporated into vandalism detection tools. We describe a method for training classifiers for vandalism detection that yields classifiers that are more accurate on the PAN 2010 corpus than others previously developed. Because of the high turnaround in social network systems, it is important for vandalism detection tools to run in real-time. To this aim, we use feature selection to find the minimal set of features consistent with high accuracy. In addition, because some features are more costly to compute than others, we use cost-sensitive feature selection to reduce the total computational cost of executing our models. In addition to the features previously used for spam detection, we introduce new features based on user action histories. The user history features contribute significantly to classifier performance. The approach we use is general and can easily be applied to other user generated content systems.
Kishore, Amit; Vail, Andy; Majid, Arshad; Dawson, Jesse; Lees, Kennedy R; Tyrrell, Pippa J; Smith, Craig J
2014-02-01
Atrial fibrillation (AF) confers a high risk of recurrent stroke, although detection methods and definitions of paroxysmal AF during screening vary. We therefore undertook a systematic review and meta-analysis to determine the frequency of newly detected AF using noninvasive or invasive cardiac monitoring after ischemic stroke or transient ischemic attack. Prospective observational studies or randomized controlled trials of patients with ischemic stroke, transient ischemic attack, or both, who underwent any cardiac monitoring for a minimum of 12 hours, were included after electronic searches of multiple databases. The primary outcome was detection of any new AF during the monitoring period. We prespecified subgroup analysis of selected (prescreened or cryptogenic) versus unselected patients and according to duration of monitoring. A total of 32 studies were analyzed. The overall detection rate of any AF was 11.5% (95% confidence interval, 8.9%-14.3%), although the timing, duration, method of monitoring, and reporting of diagnostic criteria used for paroxysmal AF varied. Detection rates were higher in selected (13.4%; 95% confidence interval, 9.0%-18.4%) than in unselected patients (6.2%; 95% confidence interval, 4.4%-8.3%). There was substantial heterogeneity even within specified subgroups. Detection of AF was highly variable, and the review was limited by small sample sizes and marked heterogeneity. Further studies are required to inform patient selection, optimal timing, methods, and duration of monitoring for detection of AF/paroxysmal AF.
The effects of running cadence manipulation on plantar loading in healthy runners.
Wellenkotter, J; Kernozek, T W; Meardon, S; Suchomel, T
2014-08-01
Our purpose was to evaluate effects of cadence manipulation on plantar loading during running. Participants (n=38) ran on a treadmill at their preferred speed in 3 conditions: preferred, 5% increased, and 5% decreased while measured using in-shoe sensors. Data (contact time [CT], peak force [PF], force time integral [FTI], pressure time integral [PTI] and peak pressure [PP]) were recorded for 30 right footfalls. Multivariate analysis was performed to detect differences in loading between cadences in the total foot and 4 plantar regions. Differences in plantar loading occurred between cadence conditions. Total foot CT and PF were lower with a faster cadence, but no total foot PP differences were observed. Faster cadence reduced CT, pressure and force variables in both the heel and metatarsal regions. Increasing cadence did not elevate metatarsal loads; rather, total foot and all regions were reduced when healthy runners increased their cadence. If a 5% increase in cadence from preferred were maintained over each mile run the impulse at the heel would be reduced by an estimated 565 body weights*s (BW*s) and the metatarsals 140-170 BW*s per mile run despite the increased steps taken. Increasing cadence may benefit overuse injuries associated with elevated plantar loading. © Georg Thieme Verlag KG Stuttgart · New York.
[Determination of total phthalates in perfume and their exposure assessment].
Zhao, Sihan; Wang, Zhengmeng; Deng, Hongxia; Duan, Jiahui; Wang, Jinyi; Liu, Shuhui
2017-12-08
A novel method for rapid screening of phthalates (PAEs) in perfumes was developed. The PAEs were hydrolyzed to phthalic acid (PA), and the PA in the acidified solution was extracted with tributyl phosphate (TBP) which was detected by high performance liquid chromatography-diode array detection (HPLC-DAD). Meanwhile exposure dose to PAEs was estimated by the percentage of a topically applied dose that permeates the skin. The parameters such as the concentration and volume of KOH, the volume of ethanol, hydrolysis time and temperature were employed to evaluate the hydrolysis efficiency of PAEs. The optimized hydrolysis conditions were 10 mL of 4 mol/L KOH, and 1 mL of ethanol at 80℃ for 20 min. The linear range of phthalic acid was 3-240 μmol/L with a good correlation coefficient ( R 2 =0.9991). The limits of detection (LOD) and quantification (LOQ) were 4.6 μmol/kg and 5.9 μmol/kg, respectively. The recoveries varied from 83.4% to 92.7% with relative standard deviations equal to or lower than 6.8%( n =5). A total of 35 perfume samples were determined, and the contents of total PAEs were found in the range of < LOD-77.738 mmol/kg, and the max exposure dose to PAEs for female adults was 0.4742 μg/(kg·d) through use of perfumes. The method is simple and reliable, and has a wide range of applicability. It can be used as a new choice for the detection of PAEs in perfume.
TaqMan based real time PCR assay targeting EML4-ALK fusion transcripts in NSCLC.
Robesova, Blanka; Bajerova, Monika; Liskova, Kvetoslava; Skrickova, Jana; Tomiskova, Marcela; Pospisilova, Sarka; Mayer, Jiri; Dvorakova, Dana
2014-07-01
Lung cancer with the ALK rearrangement constitutes only a small fraction of patients with non-small cell lung cancer (NSCLC). However, in the era of molecular-targeted therapy, efficient patient selection is crucial for successful treatment. In this context, an effective method for EML4-ALK detection is necessary. We developed a new highly sensitive variant specific TaqMan based real time PCR assay applicable to RNA from formalin-fixed paraffin-embedded tissue (FFPE). This assay was used to analyze the EML4-ALK gene in 96 non-selected NSCLC specimens and compared with two other methods (end-point PCR and break-apart FISH). EML4-ALK was detected in 33/96 (34%) specimens using variant specific real time PCR, whereas in only 23/96 (24%) using end-point PCR. All real time PCR positive samples were confirmed with direct sequencing. A total of 46 specimens were subsequently analyzed by all three detection methods. Using variant specific real time PCR we identified EML4-ALK transcript in 17/46 (37%) specimens, using end-point PCR in 13/46 (28%) specimens and positive ALK rearrangement by FISH was detected in 8/46 (17.4%) specimens. Moreover, using variant specific real time PCR, 5 specimens showed more than one EML4-ALK variant simultaneously (in 2 cases the variants 1+3a+3b, in 2 specimens the variants 1+3a and in 1 specimen the variant 1+3b). In one case of 96 EML4-ALK fusion gene and EGFR mutation were detected. All simultaneous genetic variants were confirmed using end-point PCR and direct sequencing. Our variant specific real time PCR assay is highly sensitive, fast, financially acceptable, applicable to FFPE and seems to be a valuable tool for the rapid prescreening of NSCLC patients in clinical practice, so, that most patients able to benefit from targeted therapy could be identified. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Schepkin, Victor D.; Neubauer, Andreas; Nagel, Armin M.; Budinger, Thomas F.
2017-04-01
Potassium and sodium specific binding in vivo were explored at 21.1 T by triple quantum (TQ) magnetic resonance (MR) signals without filtration to achieve high sensitivities and precise quantifications. The pulse sequence used time proportional phase increments (TPPI). During simultaneous phase-time increments, it provided total single quantum (SQ) and TQ MR signals in the second dimension at single and triple quantum frequencies, respectively. The detection of both TQ and SQ signals was performed at identical experimental conditions and the resulting TQ signal equals 60 ± 3% of the SQ signal when all ions experience sufficient time for binding. In a rat head in vivo the TQ percentage relative to SQ for potassium is 41.5 ± 3% and for sodium is 16.1 ± 1%. These percentages were compared to the matching values in an agarose tissue model with MR relaxation times similar to those of mammalian brain tissue. The sodium TQ signal in agarose samples decreased in the presence of potassium, suggesting a competitive binding of potassium relative to sodium ions for the same binding sites. The TQTPPI signals correspond to almost two times more effective binding of potassium than sodium. In vivo, up to ∼69% of total potassium and ∼27% of total sodium can be regarded as bound or experiencing an association time in the range of several milliseconds. Experimental data analyses show that more than half of the in vivo total sodium TQ signal could be from extracellular space, which is an important factor for quantification of intracellular MR signals.
Electrochemical high-temperature gas sensors
NASA Astrophysics Data System (ADS)
Saruhan, B.; Stranzenbach, M.; Yüce, A.; Gönüllü, Y.
2012-06-01
Combustion produced common air pollutant, NOx associates with greenhouse effects. Its high temperature detection is essential for protection of nature. Component-integration capable high-temperature sensors enable the control of combustion products. The requirements are quantitative detection of total NOx and high selectivity at temperatures above 500°C. This study reports various approaches to detect NO and NO2 selectively under lean and humid conditions at temperatures from 300°C to 800°C. All tested electrochemical sensors were fabricated in planar design to enable componentintegration. We suggest first an impedance-metric gas sensor for total NOx-detection consisting of NiO- or NiCr2O4-SE and PYSZ-electrolyte. The electrolyte-layer is about 200μm thickness and constructed of quasi-single crystalline columns. The sensing-electrode (SE) is magnetron sputtered thin-layers of NiO or NiCr2O4. Sensor sensitivity for detection of total NOx has been measured by applying impedance analysis. The cross-sensitivity to other emission gases such as CO, CO2, CH4 and oxygen (5 vol.%) has been determined under 0-1000ppm NO. Sensor maintains its high sensitivity at temperatures up to 550°C and 600°C, depending on the sensing-electrode. NiO-SE yields better selectivity to NO in the presence of oxygen and have shorter response times comparing to NiCr2O4-SE. For higher temperature NO2-sensing capability, a resistive DC-sensor having Al-doped TiO2-sensing layers has been employed. Sensor-sensitivity towards NO2 and cross-sensitivity to CO has been determined in the presence of H2O at temperatures 600°C and 800°C. NO2 concentrations varying from 25 to 100ppm and CO concentrations from 25 to 75ppm can be detected. By nano-tubular structuring of TiO2, NO2 sensitivity of the sensor was increased.
Carotid Flow Time Test Performance for the Detection of Dehydration in Children With Diarrhea.
Mackenzie, David C; Nasrin, Sabiha; Atika, Bita; Modi, Payal; Alam, Nur H; Levine, Adam C
2018-06-01
Unstructured clinical assessments of dehydration in children are inaccurate. Point-of-care ultrasound is a noninvasive diagnostic tool that can help evaluate the volume status; the corrected carotid artery flow time has been shown to predict volume depletion in adults. We sought to determine the ability of the corrected carotid artery flow time to identify dehydration in a population of children presenting with acute diarrhea in Dhaka, Bangladesh. Children presenting with acute diarrhea were recruited and rehydrated according to hospital protocols. The corrected carotid artery flow time was measured at the time of presentation. The percentage of weight change with rehydration was used to categorize each child's dehydration as severe (>9%), some (3%-9%), or none (<3%). A receiver operating characteristic curve was constructed to test the performance of the corrected carotid artery flow time for detecting severe dehydration. Linear regression was used to model the relationship between the corrected carotid artery flow time and percentage of dehydration. A total of 350 children (0-60 months) were enrolled. The mean corrected carotid artery flow time was 326 milliseconds (interquartile range, 295-351 milliseconds). The area under the receiver operating characteristic curve for the detection of severe dehydration was 0.51 (95% confidence interval, 0.42, 0.61). Linear regression modeling showed a weak association between the flow time and dehydration. The corrected carotid artery flow time was a poor predictor of severe dehydration in this population of children with diarrhea. © 2017 by the American Institute of Ultrasound in Medicine.
Selective Data Acquisition in NMR. The Quantification of Anti-phase Scalar Couplings
NASA Astrophysics Data System (ADS)
Hodgkinson, P.; Holmes, K. J.; Hore, P. J.
Almost all time-domain NMR experiments employ "linear sampling," in which the NMR response is digitized at equally spaced times, with uniform signal averaging. Here, the possibilities of nonlinear sampling are explored using anti-phase doublets in the indirectly detected dimensions of multidimensional COSY-type experiments as an example. The Cramér-Rao lower bounds are used to evaluate and optimize experiments in which the sampling points, or the extent of signal averaging at each point, or both, are varied. The optimal nonlinear sampling for the estimation of the coupling constant J, by model fitting, turns out to involve just a few key time points, for example, at the first node ( t= 1/ J) of the sin(π Jt) modulation. Such sparse sampling patterns can be used to derive more practical strategies, in which the sampling or the signal averaging is distributed around the most significant time points. The improvements in the quantification of NMR parameters can be quite substantial especially when, as is often the case for indirectly detected dimensions, the total number of samples is limited by the time available.
Sowerby, Leigh J; Wright, Erin D
2013-11-01
Septoplasty requires coaptation of the mucosal flaps at the conclusion of the procedure; classically this is done with nasal packing. Quilting sutures provide a welcome alternative to packing, but can be time-consuming to place. A septal stapler has recently been developed that provides a rapid alternative to quilting sutures but the timesaving has not been quantified. This study was a prospective, randomized trial comparing a septal stapler to quilting suture for coaptation of mucosal flaps in septoplasty. After meeting inclusion criteria, patients underwent septoplasty and inferior turbinoplasty. The total operative time, surgical segment times, including time for closure was recorded. Preoperative and postoperative Nasal Obstruction Symptom Evaluation (NOSE) scores were recorded. A sample size of 16 was determined to detect a difference of 5 minutes in closure time. A total of 16 patients were enrolled in the study. The mean time for closure with septal stapler was 35 ± 22 seconds vs 7 minutes ± 1 minute 10 seconds for suture closure (p < 0.0001). The mean total operative time using the septal stapler was 28 minutes ± 6 minutes whereas 43 minutes ± 13 minutes was required for suture (p = 0.014). No difference in postoperative complications or mucosal healing was seen; preoperative and postoperative improvement in NOSE scores was comparable. Coaptation of the mucosal flaps in septoplasty with a septal stapler affords a timesaving in the operating room with no difference in operative outcome. © 2013 ARS-AAOA, LLC.
NASA Astrophysics Data System (ADS)
McKay, L. D.; Layton, A.; Gentry, R.
2004-12-01
A multi-disciplinary group of researchers at the University of Tennessee is developing and testing a series of microbial assay methods based on real-time PCR to detect fecal bacterial concentrations and host sources in water samples. Real-time PCR is an enumeration technique based on the unique and conserved nucleic acid sequences present in all organisms. The first research task was development of an assay (AllBac) to detect total amount of Bacteroides, which represents up to 30 percent of fecal mass. Subsequent assays were developed to detect Bacteroides from cattle (BoBac) and humans (HuBac) using 16sRNA genes based on DNA sequences in the national GenBank, as well as sequences from local fecal samples. The assays potentially have significant advantages over conventional bacterial source tracking methods because: 1. unlike traditional enumeration methods, they do not require bacterial cultivation; 2. there are no known non-fecal sources of Bacteroides; 3. the assays are quantitative with results for total concentration and for each species expressed in mg/l; and 4. they show little regional variation within host species, meaning that they do not require development of extensive local gene libraries. The AllBac and BoBac assays have been used in a study of fecal contamination in a small rural watershed (Stock Creek) near Knoxville, TN, and have proven useful in identification of areas where cattle represent a significant fecal input and in development of BMPs. It is expected that these types of assays (and future assays for birds, hogs, etc.) could have broad applications in monitoring fecal impacts from Animal Feeding Operations, as well as from wildlife and human sources.
Koulikov, Victoria; Lerman, Hedva; Kesler, Mikhail; Even-Sapir, Einat
2015-12-01
Cadmium zinc telluride (CZT) solid-state detectors have been recently introduced in the field of nuclear medicine in cardiology and breast imaging. The aim of the current study was to evaluate the performance of the novel detectors (CZT) compared to that of the routine NaI(Tl) in bone scintigraphy. A dual-headed CZT-based camera dedicated originally to breast imaging has been used, and in view of the limited size of the detectors, the hands were chosen as the organ for assessment. This is a clinical study. Fifty-eight consecutive patients (total 116 hands) referred for bone scan for suspected hand pathology gave their informed consent to have two acquisitions, using the routine camera and the CZT-based camera. The latter was divided into full-dose full-acquisition time (FD CZT) and reduced-dose short-acquisition time (RD CZT) on CZT technology, so three image sets were available for analysis. Data analysis included comparing the detection of hot lesions and identification of the metacarpophalangeal, proximal interphalangeal, and distal interphalangeal joints. A total of 69 hot lesions were detected on the CZT image sets; of these, 61 were identified as focal sites of uptake on NaI(Tl) data. On FD CZT data, 385 joints were identified compared to 168 on NaI(Tl) data (p < 0.001). There was no statistically significant difference in delineation of joints between FD and RD CZT data as the latter identified 383 joints. Bone scintigraphy using a CZT-based gamma camera is associated with improved lesion detection and anatomic definition. The superior physical characteristics of this technique raised a potential reduction in administered dose and/or acquisition time without compromising image quality.
Temporal radiographic texture analysis in the detection of periprosthetic osteolysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilkie, Joel R.; Giger, Maryellen L.; Chinander, Michael R.
2008-01-15
Periprosthetic osteolysis is one of the most serious long-term problems in total hip arthroplasty. It has been primarily attributed to the body's inflammatory response to submicron polyethylene particles worn from the hip implant, and it leads to bone loss and structural deterioration in the surrounding bone. It was previously demonstrated that radiographic texture analysis (RTA) has the ability to distinguish between osteolysis and normal cases at the time of clinical detection of the disease; however, that analysis did not take into account the changes in texture over time. The goal of this preliminary analysis, however, is to assess the abilitymore » of temporal radiographic texture analysis (tRTA) to distinguish between patients who develop osteolysis and normal cases. Two tRTA methods were used in the study: the RTA feature change from baseline at various follow-up intervals and the slope of the best-fit line to the RTA data series. These tRTA methods included Fourier-based and fractal-based features calculated from digitized images of 202 total hip replacement cases, including 70 that developed osteolysis. Results show that separation between the osteolysis and normal groups increased over time for the feature difference method, as the disease progressed, with area under the curve (AUC) values from receiver operating characteristic analysis of 0.65 to 0.72 at 15 years postsurgery. Separation for the slope method was also evident, with AUC values ranging from 0.65 to 0.76 for the task of distinguishing between osteolysis and normal cases. The results suggest that tRTA methods have the ability to measure changes in trabecular structure, and may be useful in the early detection of periprosthetic osteolysis.« less
Teschke, K; Hertzman, C; Morrison, B
1994-03-01
Personal respirable (N = 230) and total (N = 237) dust measurements were made in two coastal British Columbia sawmills using a sampling strategy that randomly selected workers from all jobs in the mills over two seasons. Information about job title, department, season, weather conditions, location of the job relative to wood-cutting machines, and control measures also was collected at the time of sampling. Only 16 respirable wood dust samples were above the detection limit of 0.08 mg/m3; all 16 had levels < or = 0.20 mg/m3. Total wood dust concentrations were also low (36% less than the detection limit), with a mean of 0.51 mg/m3, and ranging from < 0.08 to 52 mg/m3. Measurements of exposure taken close to chippers, planers, and multiple saws had the highest total wood dust levels. Sawmill department and booth enclosures also were associated with wood dust concentrations, while local exhaust ventilation and weather conditions were not. Wood dust levels in this study were generally lower than in other studies of this industry, but most sawmill investigations report mean wood dust concentrations lower than those measured in the furniture and cabinetmaking industries, where concerns about wood dust exposures initially were raised.
Legrand, Matthieu; Gits-Muselli, Maud; Boutin, Louis; Garcia-Hermoso, Dea; Maurel, Véronique; Soussi, Sabri; Benyamina, Mourad; Ferry, Axelle; Chaussard, Maïté; Hamane, Samia; Denis, Blandine; Touratier, Sophie; Guigue, Nicolas; Fréalle, Emilie; Jeanne, Mathieu; Shaal, Jean-Vivien; Soler, Charles; Mimoun, Maurice; Chaouat, Marc; Lafaurie, Matthieu; Mebazaa, Alexandre; Bretagne, Stéphane; Alanio, Alexandre
2016-11-15
Invasive wound mucormycosis (IWM) is associated with an extremely poor outcome among critically ill burn patients. We describe the detection of circulating Mucorales DNA (cmDNA) for the early diagnosis of IWM in those patients and report the potential value of detecting cmDNA for treatment guidance. Severely ill burn patients admitted to our tertiary referral center between October 2013 and February 2016 were included. Retrospective plasma samples were tested for the presence of cmDNA by quantitative real-time polymerase chain reaction (qPCR). Patients were then prospectively screened twice a week, and liposomal amphotericin-B therapy initiated based on a positive qPCR. The primary endpoint was the time between cmDNA detection and standard diagnosis. Secondary endpoints were the time from cmDNA detection and treatment initiation and mortality. Seventy-seven patients (418 samples) were included. The average age was 46 (28-60) years, abbreviated burn severity index was 8 (7-10), and simplified acute physiology score was 33 (23-46). The total body surface area was 33% (22%-52%). cmDNA was detected 11 (4.5-15) days before standard diagnosis. The in-hospital mortality was 62% for patients with IWM and 24% for those without (P = .03). The mortality due to IWM was 80% during period A and 33% during period B (P = .46). This study suggests that the detection of cmDNA allows earlier diagnosis of IWM in severely ill burn patients and earlier initiation of treatment. Further studies are needed to confirm the impact of earlier treatment initiation on patient outcome. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Akhoondzadeh, M.
2013-09-01
Anomaly detection is extremely important for forecasting the date, location and magnitude of an impending earthquake. In this paper, an Adaptive Network-based Fuzzy Inference System (ANFIS) has been proposed to detect the thermal and Total Electron Content (TEC) anomalies around the time of the Varzeghan, Iran, (Mw = 6.4) earthquake jolted in 11 August 2012 NW Iran. ANFIS is the famous hybrid neuro-fuzzy network for modeling the non-linear complex systems. In this study, also the detected thermal and TEC anomalies using the proposed method are compared to the results dealing with the observed anomalies by applying the classical and intelligent methods including Interquartile, Auto-Regressive Integrated Moving Average (ARIMA), Artificial Neural Network (ANN) and Support Vector Machine (SVM) methods. The duration of the dataset which is comprised from Aqua-MODIS Land Surface Temperature (LST) night-time snapshot images and also Global Ionospheric Maps (GIM), is 62 days. It can be shown that, if the difference between the predicted value using the ANFIS method and the observed value, exceeds the pre-defined threshold value, then the observed precursor value in the absence of non seismic effective parameters could be regarded as precursory anomaly. For two precursors of LST and TEC, the ANFIS method shows very good agreement with the other implemented classical and intelligent methods and this indicates that ANFIS is capable of detecting earthquake anomalies. The applied methods detected anomalous occurrences 1 and 2 days before the earthquake. This paper indicates that the detection of the thermal and TEC anomalies derive their credibility from the overall efficiencies and potentialities of the five integrated methods.
LIFESPAN: A tool for the computer-aided design of longitudinal studies
Brandmaier, Andreas M.; von Oertzen, Timo; Ghisletta, Paolo; Hertzog, Christopher; Lindenberger, Ulman
2015-01-01
Researchers planning a longitudinal study typically search, more or less informally, a multivariate space of possible study designs that include dimensions such as the hypothesized true variance in change, indicator reliability, the number and spacing of measurement occasions, total study time, and sample size. The main search goal is to select a research design that best addresses the guiding questions and hypotheses of the planned study while heeding applicable external conditions and constraints, including time, money, feasibility, and ethical considerations. Because longitudinal study selection ultimately requires optimization under constraints, it is amenable to the general operating principles of optimization in computer-aided design. Based on power equivalence theory (MacCallum et al., 2010; von Oertzen, 2010), we propose a computational framework to promote more systematic searches within the study design space. Starting with an initial design, the proposed framework generates a set of alternative models with equal statistical power to detect hypothesized effects, and delineates trade-off relations among relevant parameters, such as total study time and the number of measurement occasions. We present LIFESPAN (Longitudinal Interactive Front End Study Planner), which implements this framework. LIFESPAN boosts the efficiency, breadth, and precision of the search for optimal longitudinal designs. Its initial version, which is freely available at http://www.brandmaier.de/lifespan, is geared toward the power to detect variance in change as specified in a linear latent growth curve model. PMID:25852596
Jiang, Qikun; Liu, Wanjun; Li, Xiaoting; Zhang, Tianhong; Wang, Yongjun; Liu, Xiaohong
2016-01-01
Supercritical fluid chromatography with tandem mass spectrometry was used to comprehensively profile polyene phosphatidyl choline (PPC) extracted from soybean. We achieved an efficient chromatographic analysis using a BEH-2EP column (3 × 100 mm(2) , 1.7 μm) with a mobile phase consisting of CO2 and a cosolvent in gradient combination at a flow rate of 1.0 mL/min. The cosolvent consisted of methanol, acetonitrile, and water (containing 10 mM ammonium acetate and 0.2% formic acid). The total single-run time was 7 min. We used this method to accurately detect ten different phospholipids (PLs) during extraction. The limits of quantification for phosphatidyl choline, lyso-phosphatidylcholine (LPC), phosphatidic acid (PA), sphingomyelin, phosphatidyl glycerol, phosphatidyl inositol (PI), cholesterol, cardiolipin, phosphatidyl serine, and phosphatidyl ethanolamine (PE) were 20.6, 19.52, 1.21, 2.38, 0.50, 2.28, 54.3, 0.60, 0.65, and 4.85 ng/mL, respectively. However, adopting the high-performance liquid chromatography with evaporative light scattering detection method issued by the China Food and Drug Administration, only PA, LPC, PE, PI, and PPC could be analyzed accurately, and the limits of quantification were 33.89, 60.5, 30.3, 10.9, and 61.79 μg/mL, respectively. The total single-run time was at the least 20 min. Consequently, the supercritical fluid chromatography with tandem mass spectrometry method was more suitable for the analysis of related PLs. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Detection and genetic analysis of human sapoviruses in river water in Japan.
Kitajima, Masaaki; Oka, Tomoichiro; Haramoto, Eiji; Katayama, Hiroyuki; Takeda, Naokazu; Katayama, Kazuhiko; Ohgaki, Shinichiro
2010-04-01
We investigated the prevalence of sapoviruses (SaVs) in the Tamagawa River in Japan from April 2003 to March 2004 and performed genetic analysis of the SaV genes identified in river water. A total of 60 river water samples were collected from five sites along the river, and 500 ml was concentrated using the cation-coated filter method. By use of a real-time reverse transcription (RT)-PCR assay, 12 (20%) of the 60 samples were positive for SaV. SaV sequences were obtained from 15 (25%) samples, and a total of 30 SaV strains were identified using six RT-PCR assays followed by cloning and sequence analysis. A newly developed nested RT-PCR assay utilizing a broadly reactive forward primer showed the highest detection efficiency and amplified more diverse SaV genomes in the samples. SaV sequences were frequently detected from November to March, whereas none were obtained in April, July, September, or October. No SaV sequences were detected in the upstream portion of the river, whereas the midstream portion showed high positive rates. Based on phylogenetic analysis, SaV strains identified in the river water samples were classified into nine genotypes, namely, GI/1, GI/2, GI/3, GI/5, GI/untyped, GII/1, GII/2, GII/3, and GV/1. To our knowledge, this is the first study describing seasonal and spatial distributions and genetic diversity of SaVs in river water. A combination of real-time RT-PCR assay and newly developed nested RT-PCR assay is useful for identifying and characterizing SaV strains in a water environment.
Kema, I P; Meijer, W G; Meiborg, G; Ooms, B; Willemse, P H; de Vries, E G
2001-10-01
Profiling of the plasma indoles tryptophan, 5-hydroxytryptophan (5-HTP), serotonin, and 5-hydroxyindoleacetic acid (5-HIAA) is useful in the diagnosis and follow-up of patients with carcinoid tumors. We describe an automated method for the profiling of these indoles in protein-containing matrices as well as the plasma indole concentrations in healthy controls and patients with carcinoid tumors. Plasma, cerebrospinal fluid, and tissue homogenates were prepurified by automated on-line solid-phase extraction (SPE) in Hysphere Resin SH SPE cartridges containing strong hydrophobic polystyrene resin. Analytes were eluted from the SPE cartridge by column switching. Subsequent separation and detection were performed by reversed-phase HPLC combined with fluorometric detection in a total cycle time of 20 min. We obtained samples from 14 healthy controls and 17 patients with metastasized midgut carcinoid tumors for plasma indole analysis. In the patient group, urinary excretion of 5-HIAA and serotonin was compared with concentrations of plasma indoles. Within- and between-series CVs for indoles in platelet-rich plasma were 0.6-6.2% and 3.7-12%, respectively. Results for platelet-rich plasma serotonin compared favorably with those obtained by single-component analysis. Plasma 5-HIAA, but not 5-HTP was detectable in 8 of 17 patients with carcinoid tumors. In the patient group, platelet-rich plasma total tryptophan correlated negatively with platelet-rich plasma serotonin (P = 0.021; r = -0.56), urinary 5-HIAA (P = 0.003; r = -0.68), and urinary serotonin (P <0.0001; r = -0.80). The present chromatographic approach reduces analytical variation and time needed for analysis and gives more detailed information about metabolic deviations in indole metabolism than do manual, single-component analyses.
mcrA-Targeted Real-Time Quantitative PCR Method To Examine Methanogen Communities▿
Steinberg, Lisa M.; Regan, John M.
2009-01-01
Methanogens are of great importance in carbon cycling and alternative energy production, but quantitation with culture-based methods is time-consuming and biased against methanogen groups that are difficult to cultivate in a laboratory. For these reasons, methanogens are typically studied through culture-independent molecular techniques. We developed a SYBR green I quantitative PCR (qPCR) assay to quantify total numbers of methyl coenzyme M reductase α-subunit (mcrA) genes. TaqMan probes were also designed to target nine different phylogenetic groups of methanogens in qPCR assays. Total mcrA and mcrA levels of different methanogen phylogenetic groups were determined from six samples: four samples from anaerobic digesters used to treat either primarily cow or pig manure and two aliquots from an acidic peat sample stored at 4°C or 20°C. Only members of the Methanosaetaceae, Methanosarcina, Methanobacteriaceae, and Methanocorpusculaceae and Fen cluster were detected in the environmental samples. The three samples obtained from cow manure digesters were dominated by members of the genus Methanosarcina, whereas the sample from the pig manure digester contained detectable levels of only members of the Methanobacteriaceae. The acidic peat samples were dominated by both Methanosarcina spp. and members of the Fen cluster. In two of the manure digester samples only one methanogen group was detected, but in both of the acidic peat samples and two of the manure digester samples, multiple methanogen groups were detected. The TaqMan qPCR assays were successfully able to determine the environmental abundance of different phylogenetic groups of methanogens, including several groups with few or no cultivated members. PMID:19447957
Koopman, K E; Roefs, A; Elbers, D C E; Fliers, E; Booij, J; Serlie, M J; la Fleur, S E
2016-06-01
In rodents, the striatal dopamine (DA) system and the (hypo)thalamic serotonin (5-HT) system are involved in the regulation of feeding behavior. In lean humans, little is known about the relationship between these brain neurotransmitter systems and feeding. We studied the relationship between striatal DA transporters (DAT) and diencephalic 5-HT transporters (SERT), behavioral tasks and questionnaires, and food intake. We measured striatal DAT and diencephalic SERT binding with [123I]FP-CIT SPECT in 36 lean male subjects. Visual attention bias for food (detection speed and distraction time) and degree of impulsivity were measured using response-latency-based computer tasks. Craving and emotional eating were assessed with questionnaires and ratings of hunger by means of VAS scores. Food intake was assessed through a self-reported online diet journal. Striatal DAT and diencephalic SERT binding negatively correlated with food detection speed (p = 0.008, r = -0.50 and p = 0.002, r = -0.57, respectively), but not with food distraction time, ratings of hunger, craving or impulsivity. Striatal DAT and diencephalic SERT binding did not correlate with free choice food intake, whereas food detection speed positively correlated with total caloric intake (p = 0.001, r = 0.60), protein intake (p = 0.01, r = 0.44), carbohydrate intake (p = 0.03, r = 0.39) and fat intake (p = 0.06, r = 0.35). These results indicate a role for the central 5-HT and DA system in the regulation of visual attention bias for food, which contributes to the motivation to eat, in non-obese, healthy humans. In addition, this study confirms that food detection speed, measured with the latency-based computer task, positively correlates with total food and macronutrient intake.
Kahramangil, Bora; Berber, Eren
2017-12-01
Indocyanine green fluorescence (ICGF) and parathyroid autofluorescence (AF) are two new techniques that aid in the identification of parathyroid glands (PG) intraoperatively during thyroidectomy. There is no study comparing the efficacy of these techniques. This was an IRB-approved clinical study comparing the utility of ICGF and AF for identification of PGs during thyroidectomy. Data were collected prospectively. Both techniques were compared to naked eye (NE) for PG detection. Standard statistical methods were used for data analysis. Twenty-two patients in each group underwent a total of 39 total thyroidectomies and 5 thyroid lobectomies. AF and ICGF had similar detection rates for PGs [98% (61 of 62) and 95% (60 of 63) of PGs, respectively; P=0.31]. The location of PGs was suggested before detection with NE more frequently by AF than ICGF [52% (32 of 62) vs. 6% (4 of 63) of PGs; P<0.001]. In 82% (18 of 22) of patients at least one PG was detected by AF before NE, as opposed to 14% (3 of 22) by ICGF (P<0.001). The median (range) number of PGs detected before NE per patient was greater with AF than ICGF [2 (0-3) vs. 0 (0-2)];. Upper PGs were more likely to be detected by AF before recognition with NE than the lower ones (P=0.03). There was no predictive factor for ICGF detection. Postoperative hypocalcemia rates were similar [9% (2 of 22) and 5% (1 of 22) for AF and ICGF, respectively; P>0.99]. To the best of our knowledge, this is the first comparative study between parathyroid AF and ICGF in detection of PGs during thyroidectomy. Our data suggest both techniques have similarly high detection rates and that the main difference lies in the timing of detection. AF more frequently detects PGs before recognition with NE compared to ICGF.
Kahramangil, Bora
2017-01-01
Background Indocyanine green fluorescence (ICGF) and parathyroid autofluorescence (AF) are two new techniques that aid in the identification of parathyroid glands (PG) intraoperatively during thyroidectomy. There is no study comparing the efficacy of these techniques. Methods This was an IRB-approved clinical study comparing the utility of ICGF and AF for identification of PGs during thyroidectomy. Data were collected prospectively. Both techniques were compared to naked eye (NE) for PG detection. Standard statistical methods were used for data analysis. Results Twenty-two patients in each group underwent a total of 39 total thyroidectomies and 5 thyroid lobectomies. AF and ICGF had similar detection rates for PGs [98% (61 of 62) and 95% (60 of 63) of PGs, respectively; P=0.31]. The location of PGs was suggested before detection with NE more frequently by AF than ICGF [52% (32 of 62) vs. 6% (4 of 63) of PGs; P<0.001]. In 82% (18 of 22) of patients at least one PG was detected by AF before NE, as opposed to 14% (3 of 22) by ICGF (P<0.001). The median (range) number of PGs detected before NE per patient was greater with AF than ICGF [2 (0–3) vs. 0 (0–2)];. Upper PGs were more likely to be detected by AF before recognition with NE than the lower ones (P=0.03). There was no predictive factor for ICGF detection. Postoperative hypocalcemia rates were similar [9% (2 of 22) and 5% (1 of 22) for AF and ICGF, respectively; P>0.99]. Conclusions To the best of our knowledge, this is the first comparative study between parathyroid AF and ICGF in detection of PGs during thyroidectomy. Our data suggest both techniques have similarly high detection rates and that the main difference lies in the timing of detection. AF more frequently detects PGs before recognition with NE compared to ICGF. PMID:29302480
Redox-initiated hydrogel system for detection and real-time imaging of cellulolytic enzyme activity.
Malinowska, Klara H; Verdorfer, Tobias; Meinhold, Aylin; Milles, Lukas F; Funk, Victor; Gaub, Hermann E; Nash, Michael A
2014-10-01
Understanding the process of biomass degradation by cellulolytic enzymes is of urgent importance for biofuel and chemical production. Optimizing pretreatment conditions and improving enzyme formulations both require assays to quantify saccharification products on solid substrates. Typically, such assays are performed using freely diffusing fluorophores or dyes that measure reducing polysaccharide chain ends. These methods have thus far not allowed spatial localization of hydrolysis activity to specific substrate locations with identifiable morphological features. Here we describe a hydrogel reagent signaling (HyReS) system that amplifies saccharification products and initiates crosslinking of a hydrogel that localizes to locations of cellulose hydrolysis, allowing for imaging of the degradation process in real time. Optical detection of the gel in a rapid parallel format on synthetic and natural pretreated solid substrates was used to quantify activity of T. emersonii and T. reesei enzyme cocktails. When combined with total internal reflection fluorescence microscopy and AFM imaging, the reagent system provided a means to visualize enzyme activity in real-time with high spatial resolution (<2 μm). These results demonstrate the versatility of the HyReS system in detecting cellulolytic enzyme activity and suggest new opportunities in real-time chemical imaging of biomass depolymerization. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hyperspectral imaging for food processing automation
NASA Astrophysics Data System (ADS)
Park, Bosoon; Lawrence, Kurt C.; Windham, William R.; Smith, Doug P.; Feldner, Peggy W.
2002-11-01
This paper presents the research results that demonstrates hyperspectral imaging could be used effectively for detecting feces (from duodenum, ceca, and colon) and ingesta on the surface of poultry carcasses, and potential application for real-time, on-line processing of poultry for automatic safety inspection. The hyperspectral imaging system included a line scan camera with prism-grating-prism spectrograph, fiber optic line lighting, motorized lens control, and hyperspectral image processing software. Hyperspectral image processing algorithms, specifically band ratio of dual-wavelength (565/517) images and thresholding were effective on the identification of fecal and ingesta contamination of poultry carcasses. A multispectral imaging system including a common aperture camera with three optical trim filters (515.4 nm with 8.6- nm FWHM), 566.4 nm with 8.8-nm FWHM, and 631 nm with 10.2-nm FWHM), which were selected and validated by a hyperspectral imaging system, was developed for a real-time, on-line application. A total image processing time required to perform the current multispectral images captured by a common aperture camera was approximately 251 msec or 3.99 frames/sec. A preliminary test shows that the accuracy of real-time multispectral imaging system to detect feces and ingesta on corn/soybean fed poultry carcasses was 96%. However, many false positive spots that cause system errors were also detected.
Garber, Eric A E; Thole, Joseph
2015-06-11
The utility of microwave irradiation to accelerate the onset of equilibrium and improve ELISA performance was examined using ELISAs for the detection of the plant toxin ricin and gliadin. The ricin ELISA normally requires several one hour incubations at 37 °C, a total assay time of approximately five hours, and employs a complex buffer containing PBS, Tween-20®, and non-fat milk. Different energy levels and pulse designs were compared to the use of abbreviated incubation times at 37 °C for the detection of ricin in food. The use of microwave irradiation had no significant advantage over the application of heat using an oven incubator and performed worse with some foods. In contrast, a gliadin ELISA that relied on 30 min incubation steps at room temperature and a salt-based buffer performed better upon irradiation but also displayed improvement upon incubating the microtiter plate at 37 °C. Whether microwave irradiation was advantageous compared to incubation in an oven was inconclusive. However, by abbreviating the incubation time of the ricin ELISA, it was possible to cut the assay time to less than 2 hours and still display LOD values < 10 ppb and recoveries of 78%-98%.
NASA Astrophysics Data System (ADS)
MacDonald, I. R.; Garcia-Pineda, O. G.; Solow, A.; Daneshgar, S.; Beet, A.
2013-12-01
Oil discharged as a result of the Deepwater Horizon disaster was detected on the surface of the Gulf of Mexico by synthetic aperture radar satellites from 25 April 2010 until 4 August 2010. SAR images were not restricted by daylight or cloud-cover. Distribution of this material is a tracer for potential environmental impacts and an indicator of impact mitigation due to response efforts and physical forcing factors. We used a texture classifying neural network algorithm for semi-supervised processing of 176 SAR images from the ENVISAT, RADARSAT I, and COSMO-SKYMED satellites. This yielded an estimate the proportion of oil-covered water within the region sampled by each image with a nominal resolution of 10,000 sq m (100m pixels), which was compiled as a 5-km equal area grid covering the northern Gulf of Mexico. Few images covered the entire impact area, so analysis was required to compile a regular time-series of the oil cover. A Gaussian kernel using a bandwidth of 2 d was used to estimate oil cover percent in each grid at noon and midnight throughout the interval. Variance and confidence intervals were calculated for each grid and for the global 12-h totals. Results animated across the impact region show the spread of oil under the influence of physical factors. Oil cover reached an early peak of 17032.26 sq km (sd 460.077) on 18 May, decreasing to 27% of this total on 4 June, following by sharp increase to an overall maximum of 18424.56 sq km (sd 424.726) on 19 June. There was a significant negative correlation between average wind stress and the total area of oil cover throughout the time-series. Correlation between response efforts including aerial and subsurface application of dispersants and burning of gathered oil was negative, positive, or indeterminate at different time segments during the event. Daily totals for oil-covered surface waters of the Gulf of Mexico during 25 April - 9 August 2010 with upper and lower 0.95 confidence limits on estimate. (No oil visible after 4 August.)
Xiao, Gui Nan; Sun, Qing Ping; Chen, Hao An
2013-01-15
Chlorogenic acid (CA) is one of the active ingredients in some Chinese herbal injections, which may cause allergic reactions in clinic therapy. However, the criterion of test for allergen had not been employed in current Pharmacopeia of United States, European Pharmacopeia, Japanese Pharmacopeia and British Pharmacopeia. In order to find a new way to predict allergic reactions induced by CA earlier, the guinea pigs were sensitized successively by injecting CA intravenously once a day for three times, the results were compared that of Chinese Pharmacopeia by injecting CA intraperitoneally once every other day for three times, serum IL-4 and total IgE were detected by method of enzyme linked immunosorbent assay (ELISA) before guinea pigs were challenged once by injecting the same drug intravenously. The time-effectiveness and dose-effect of allergic reactions induced by CA were also studied. We found that contents of serum IL-4 and total IgE increased significantly before guinea pigs were challenged, either in D8 after intravenous sensitization (1.5 g/l CA, 0.5 ml) or in D14 and D21 after intraperitoneal sensitization (1.5 g/l CA, 0.5 ml), and allergic reactions occurred in all guinea pigs after challenged once by injecting CA (1.5 g/l, 1.0 ml) intravenously. It provides a new way to predict whether CA (or Chinese herbal injections contained CA) can provoke allergic reactions by detecting serum IL-4 and total IgE earlier; the examination period is reduced by 1-2 weeks. It has a good prospect of application in drug emergency test. Copyright © 2012 Elsevier B.V. All rights reserved.
Tignon, Marylène; Gallardo, Carmina; Iscaro, Carmen; Hutet, Evelyne; Van der Stede, Yves; Kolbasov, Denis; De Mia, Gian Mario; Le Potier, Marie-Frédérique; Bishop, Richard P; Arias, Marisa; Koenen, Frank
2011-12-01
A real-time polymerase chain reaction (PCR) assay for the rapid detection of African swine fever virus (ASFV), multiplexed for simultaneous detection of swine beta-actin as an endogenous control, has been developed and validated by four National Reference Laboratories of the European Union for African swine fever (ASF) including the European Union Reference Laboratory. Primers and a TaqMan(®) probe specific for ASFV were selected from conserved regions of the p72 gene. The limit of detection of the new real-time PCR assay is 5.7-57 copies of the ASFV genome. High accuracy, reproducibility and robustness of the PCR assay (CV ranging from 0.7 to 5.4%) were demonstrated both within and between laboratories using different real-time PCR equipments. The specificity of virus detection was validated using a panel of 44 isolates collected over many years in various geographical locations in Europe, Africa and America, including recent isolates from the Caucasus region, Sardinia, East and West Africa. Compared to the OIE-prescribed conventional and real-time PCR assays, the sensitivity of the new assay with internal control was improved, as demonstrated by testing 281 field samples collected in recent outbreaks and surveillance areas in Europe and Africa (170 samples) together with samples obtained through experimental infections (111 samples). This is particularly evident in the early days following experimental infection and during the course of the disease in pigs sub-clinically infected with strains of low virulence (from 35 up to 70dpi). The specificity of the assay was also confirmed on 150 samples from uninfected pigs and wild boar from ASF-free areas. Measured on the total of 431 tested samples, the positive deviation of the new assay reaches 21% or 26% compared to PCR and real-time PCR methods recommended by OIE. This improved and rigorously validated real-time PCR assay with internal control will provide a rapid, sensitive and reliable molecular tool for ASFV detection in pigs in newly infected areas, control in endemic areas and surveillance in ASF-free areas. Copyright © 2011 Elsevier B.V. All rights reserved.
Cooperstone, Jessica L; Francis, David M; Schwartz, Steven J
2016-11-01
Tangerine tomatoes, unlike red tomatoes, accumulate cis-lycopenes instead of the all-trans isomer. cis-Lycopene is the predominating isomeric form of lycopene found in blood and tissues. Our objective was to understand how thermal processing and lipid concentration affect carotenoid isomerisation and degradation in tangerine tomatoes. We conducted duplicated factorial designed experiments producing tangerine tomato juice and sauce, varying both processing time and lipid concentration. Carotenoids were extracted and analysed using high-performance liquid chromatography with photodiode array detection. Phytoene, phytofluene, ζ-carotene, neurosporene, tetra-cis-lycopene, all-trans-lycopene and other-cis-lycopenes were quantified. Tetra-cis-lycopene decreased with increasing heating time and reached 80% of the original level in sauce after processing times of 180min. All-trans-lycopene and other-cis-lycopenes increased with longer processing times. Total carotenoids and total lycopene decreased with increased heating times while phytoene and phytofluene were unchanged. These data suggest limiting thermal processing of tangerine tomato products if delivery of tetra-cis-lycopene is desirable. Copyright © 2016 Elsevier Ltd. All rights reserved.
Xu, C S; Zhao, X L; Zhou, H B; Qu, Z J; Yang, Q G; Wang, H J; Wang, G
2017-10-17
Objective: To explore the efficacy and safety of bilateral axillary brachial plexus block under the guidance of ultrasound or neurostimulator. Methods: From February 2012 to April 2014, 120 patients undergoing bilateral hand/forearm surgery in Beijing Jishuitan Hospital were enrolled and anaesthetized with bilateral axillary brachial plexus block. All patients were divided into two groups randomly using random number table: the ultrasound-guided group (group U, n =60) and the neurostimulator-guidedgroup (group N, n =60). The block was performed with 0.5% ropivacaine. Patients' age, sex and operation duration were recorded. Moreover, success rate, performance time, onset of sensor and motor block, performance pain, patient satisfaction degree and the incidence of related complications were also documented. Venous samples were collected at selected time points and the total and the plasma concentrations of ropivacaine were analyzed with HPLC. Results: The performance time, the onset of sensor block and the onset of motor block of group U were (8.2±1.5), (14.2± 2.2)and (24.0±3.5)min respectively, which were markedly shorter than those in group N( (14.6±3.9), (19.9±3.8), (28.8±4.2)min, respectively), and the differences were statistically significant( t =11.74, 10.09, 6.73, respectively, all P <0.01). The performance pain score of group N was (25.5± 13.2), which was obviously more serious than group U (31.7± 11.2) and a significant statistical difference was detected ( t =2.856, P <0.05). The patient satisfaction degree of group U was 95.0%, which was significantly higher than group N (83.3%) and a markedly statistical difference was detected (χ(2)=4.227, P <0.05). Fifty min after performance, the total plasma concentration of ropivacaine of group U was(1.76±0.48)mg/L, which was significantly lower than group N (1.88±0.53)mg/L and a significant statistical difference was detected ( t =2.43, P <0.05), while no significant differences were detected at the other time points between two groups ( P >0.05). No analgesic was superadded and no other anesthesia methods were applied. No complications were detected perioperatively. Conclusions: The bilateral axillary brachial plexus block under the guidance of ultrasound or neurostimulator are both effective and safe for bilateral hand/forearm surgery. However, the ultrasound-guided block may be more clinically beneficial because of its shorter performance time, rapid onset and higher patient satisfaction degree.
Satou, Shouichi; Aoki, Taku; Kaneko, Junichi; Sakamoto, Yoshihiro; Hasegawa, Kiyoshi; Sugawara, Yasuhiko; Arai, Osamu; Mitake, Tsuyoshi; Miura, Koui; Kokudo, Norihiro
2014-02-01
Real-time virtual sonography is an innovative imaging technology that detects the spatial position of an ultrasound probe and immediately reconstructs a section of computed tomography (CT) and/or magnetic resonance in accordance with the ultrasound image, thereby allowing a real-time comparison of those modalities. A novel intraoperative navigation system for liver resection using real-time virtual sonography has been devised for the detection of tumors and navigation of the resection plane. Sixteen patients with hepatic malignancies (26 tumors in total) were involved in this study, and the system was used intraoperatively. The tumor size ranged 2 to 140 mm (23 mm in median). By the navigation system, operators could refer intraoperative ultrasound image displayed on the television monitor side-by-side with corresponding images of CT and/or magnetic resonance. In addition, the system overlaid preoperative simulation on the CT image and highlighted the extent of resection so as to navigate the resection plane. Because the system used electromagnetic power in the operation room, the feasibility and safety of the system was investigated as well as its validity. The system could be used uneventfully in each operation. All of the 26 tumors scheduled to be resected were detected by the navigation system. The weight of the resected specimen correlated with the preoperatively simulated volume (R = 0.995, P < .0001). The feasibility and safety of the navigation system were confirmed. The system should be helpful for intraoperative tumor detection and navigation of liver resection.
Scott, Laura Jane; Gunson, Rory N; Carman, William F; Winter, Andrew J
2010-12-01
To develop, evaluate and implement a new multiplex real-time PCR test for the detection of herpes simplex virus (HSV)1, HSV2 and syphilis in a single sample using a single test. A multiplex real-time PCR test detecting HSV1, HSV2 and Treponema pallidum was designed, validated and evaluated for a period of 6 months on patients attending the Sandyford Initiative (a series of genitourinary medicine clinics in and around Glasgow). A total of 692 samples were tested, and T pallidum PCR positives were confirmed by a second PCR at the Scottish Reference Laboratory (SBSTIRL). All PCR results were aligned with dark ground microscopy findings and serological results where available and compared. The laboratory validation of the multiplex assay showed the test to be sensitive, specific and robust. Of the 692 samples, 139 were positive for HSV1, 136 for HSV2, 15 for syphilis, one for both syphilis and HSV1, and 401 were negative; the reference laboratory confirmed all T pallidum PCR-positive samples. The PCR test was more sensitive than both dark ground microscopy and serological testing for the diagnosis of primary syphilis. The introduction of this new test has led to a better turnaround time for the diagnosis of genital ulcer disease, better detection of primary syphilis infection, and the detection of unexpected cases of syphilis where the aetiological agent suspected was HSV.
Comparative evaluation of three commercial systems for nucleic acid extraction from urine specimens.
Tang, Yi-Wei; Sefers, Susan E; Li, Haijing; Kohn, Debra J; Procop, Gary W
2005-09-01
A nucleic acid extraction system that can handle small numbers of specimens with a short test turnaround time and short hands-on time is desirable for emergent testing. We performed a comparative validation on three systems: the MagNA Pure compact system (Compact), the NucliSens miniMAG extraction instrument (miniMAG), and the BioRobot EZ1 system (EZ1). A total of 75 urine specimens submitted for polyomavirus BK virus detection were used. The human beta-actin gene was detected on 75 (100%), 75 (100%), and 72 (96%) nucleic acid extracts prepared by the miniMAG, EZ1, and Compact, respectively. The miniMAG produced the highest quantity of nucleic acids and the best precision among the three systems. The agreement rate was 100% for BKV detection on nucleic acid extracts prepared by the three extraction systems. When a full panel of specimens was run, the hands-on time and test turnaround time were 105.7 and 121.1 min for miniMAG, 6.1 and 22.6 min for EZ1, and 7.4 and 33.7 min for Compact, respectively. The EZ1 and Compact systems processed automatic nucleic acid extraction properly, providing a good solution to the need for sporadic but emergent specimen detection. The miniMAG yielded the highest quantity of nucleic acids, suggesting that this system would be the best for specimens containing a low number of microorganisms of interest.
Kim, Yoonjung; Han, Mi-Soon; Kim, Juwon; Kwon, Aerin; Lee, Kyung-A
2014-01-01
A total of 84 nasopharyngeal swab specimens were collected from 84 patients. Viral nucleic acid was extracted by three automated extraction systems: QIAcube (Qiagen, Germany), EZ1 Advanced XL (Qiagen), and MICROLAB Nimbus IVD (Hamilton, USA). Fourteen RNA viruses and two DNA viruses were detected using the Anyplex II RV16 Detection kit (Seegene, Republic of Korea). The EZ1 Advanced XL system demonstrated the best analytical sensitivity for all the three viral strains. The nucleic acids extracted by EZ1 Advanced XL showed higher positive rates for virus detection than the others. Meanwhile, the MICROLAB Nimbus IVD system was comprised of fully automated steps from nucleic extraction to PCR setup function that could reduce human errors. For the nucleic acids recovered from nasopharyngeal swab specimens, the QIAcube system showed the fewest false negative results and the best concordance rate, and it may be more suitable for detecting various viruses including RNA and DNA virus strains. Each system showed different sensitivity and specificity for detection of certain viral pathogens and demonstrated different characteristics such as turnaround time and sample capacity. Therefore, these factors should be considered when new nucleic acid extraction systems are introduced to the laboratory.
Automatic Identification of Alpine Mass Movements by a Combination of Seismic and Infrasound Sensors
Hübl, Johannes; McArdell, Brian W.; Walter, Fabian
2018-01-01
The automatic detection and identification of alpine mass movements such as debris flows, debris floods, or landslides have been of increasing importance for devising mitigation measures in densely populated and intensively used alpine regions. Since these mass movements emit characteristic seismic and acoustic waves in the low-frequency range (<30 Hz), several approaches have already been developed for detection and warning systems based on these signals. However, a combination of the two methods, for improving detection probability and reducing false alarms, is still applied rarely. This paper presents an update and extension of a previously published approach for a detection and identification system based on a combination of seismic and infrasound sensors. Furthermore, this work evaluates the possible early warning times at several test sites and aims to analyze the seismic and infrasound spectral signature produced by different sediment-related mass movements to identify the process type and estimate the magnitude of the event. Thus, this study presents an initial method for estimating the peak discharge and total volume of debris flows based on infrasound data. Tests on several catchments show that this system can detect and identify mass movements in real time directly at the sensor site with high accuracy and a low false alarm ratio. PMID:29789449
The detection of flaws in austenitic welds using the decomposition of the time-reversal operator
NASA Astrophysics Data System (ADS)
Cunningham, Laura J.; Mulholland, Anthony J.; Tant, Katherine M. M.; Gachagan, Anthony; Harvey, Gerry; Bird, Colin
2016-04-01
The non-destructive testing of austenitic welds using ultrasound plays an important role in the assessment of the structural integrity of safety critical structures. The internal microstructure of these welds is highly scattering and can lead to the obscuration of defects when investigated by traditional imaging algorithms. This paper proposes an alternative objective method for the detection of flaws embedded in austenitic welds based on the singular value decomposition of the time-frequency domain response matrices. The distribution of the singular values is examined in the cases where a flaw exists and where there is no flaw present. A lower threshold on the singular values, specific to austenitic welds, is derived which, when exceeded, indicates the presence of a flaw. The detection criterion is successfully implemented on both synthetic and experimental data. The datasets arising from welds containing a flaw are further interrogated using the decomposition of the time-reversal operator (DORT) method and the total focusing method (TFM), and it is shown that images constructed via the DORT algorithm typically exhibit a higher signal-to-noise ratio than those constructed by the TFM algorithm.
Sil'veĭstrova, O Iu; Domonova, É A; Shipulina, O Iu
2014-04-01
The validation of kit of reagents destined to detection and quantitative evaluation of DNA of human cytomegalovirus in biological material using polymerase chain reaction technique in real time operation mode was implemented. The comparison was made against international WHO standard--The first WHO international standard for human cytomegalovirus to implement measures the kit of reagents "AmpliSens CMV-screen/monitor-FL" and standard sample of enterprise DNA HCMV (The central research institute of epidemiology of Rospotrebnadzor) was applied. The fivefold dilution of international WHO standard and standard sample of enterprise were carried out in concentrations of DNA HCMV from 106 to 102. The arrangement of polymerase chain reaction and analysis of results were implemented using programed amplifier with system of detection of fluorescent signal in real-time mode "Rotor-Gene Q" ("Qiagen", Germany). In the total of three series of experiments, all stages of polymerase chain reaction study included, the coefficient of translation of quantitative evaluation of DNA HCMV from copy/ml to ME/ml equal to 0.6 was introduced for this kit of reagents.
The detection of flaws in austenitic welds using the decomposition of the time-reversal operator
Cunningham, Laura J.; Mulholland, Anthony J.; Gachagan, Anthony; Harvey, Gerry; Bird, Colin
2016-01-01
The non-destructive testing of austenitic welds using ultrasound plays an important role in the assessment of the structural integrity of safety critical structures. The internal microstructure of these welds is highly scattering and can lead to the obscuration of defects when investigated by traditional imaging algorithms. This paper proposes an alternative objective method for the detection of flaws embedded in austenitic welds based on the singular value decomposition of the time-frequency domain response matrices. The distribution of the singular values is examined in the cases where a flaw exists and where there is no flaw present. A lower threshold on the singular values, specific to austenitic welds, is derived which, when exceeded, indicates the presence of a flaw. The detection criterion is successfully implemented on both synthetic and experimental data. The datasets arising from welds containing a flaw are further interrogated using the decomposition of the time-reversal operator (DORT) method and the total focusing method (TFM), and it is shown that images constructed via the DORT algorithm typically exhibit a higher signal-to-noise ratio than those constructed by the TFM algorithm. PMID:27274683
Evaluation of heart rate variability indices using a real-time handheld remote ECG monitor.
Singh, Swaroop S; Carlson, Barbara W; Hsiao, Henry S
2007-12-01
Studies on retrospective electrocardiogram (ECG) recordings of patients during cardiac arrest have shown significant changes in heart rate variability (HRV) indices prior to the onset of cardiac arrhythmia. The early detection of these changes in HRV indices increases the chances for a successful medical intervention by increasing the response time window. A portable, handheld remote ECG monitor designed in this research detects the QRS complex and calculates short-term HRV indices in real-time. The QRS detection of the ECG recordings of subjects from the MIT-Arrhythmia database yielded a mean sensitivity of 99.34% and a specificity of 99.31%. ECG recordings from normal subjects and subjects with congestive heart failure were used to identify the differences in HRV indices. An increase in heart rate, high-frequency spectral power (HFP), total spectral power, the ratio of HFP to low-frequency spectral power (LFP), and a decrease in root mean square sum of RR differences were observed. No difference was found on comparison of the standard deviation of normal to normal interval between adjacent R-waves, LFP, and very-low-frequency spectral power. Based on these, additional analytical calculations could be made to provide early warnings of impending cardiac conditions.
Sanz, Miriam; Andreote, Ana Paula Dini; Fiore, Marli Fatima; Dörr, Felipe Augusto; Pinto, Ernani
2015-01-01
Cyanobacteria from underexplored and extreme habitats are attracting increasing attention in the search for new bioactive substances. However, cyanobacterial communities from tropical and subtropical regions are still largely unknown, especially with respect to metabolite production. Among the structurally diverse secondary metabolites produced by these organisms, peptides are by far the most frequently described structures. In this work, liquid chromatography/electrospray ionization coupled to high resolution quadrupole time-of-flight tandem mass spectrometry with positive ion detection was applied to study the peptide profile of a group of cyanobacteria isolated from the Southeastern Brazilian coastal forest. A total of 38 peptides belonging to three different families (anabaenopeptins, aeruginosins, and cyanopeptolins) were detected in the extracts. Of the 38 peptides, 37 were detected here for the first time. New structural features were proposed based on mass accuracy data and isotopic patterns derived from full scan and MS/MS spectra. Interestingly, of the 40 surveyed strains only nine were confirmed to be peptide producers; all of these strains belonged to the order Nostocales (three Nostoc sp., two Desmonostoc sp. and four Brasilonema sp.). PMID:26096276
Wu, Daxian; Tao, Shuhui; Liu, Shuiping; Zhou, Jiebin; Tan, Deming; Hou, Zhouhua
2017-07-28
To observe the sensitivity of transcription mediated amplification (TMA), and to compare its performance with real-time reverse transcription polymerase chain reaction (real-time RT-PCR) in detecting human immunodeficiency virus RNA (HIV RNA). Methods: TMA system was established with TaqMan probes, specific primers, moloney murine leukemia virus (MMLV) reverse transcriptase, T7 RNA polymerase, and reaction substrates. The sensitivity of TMA was evaluated by amplifying a group of 10-fold diluted HIV RNA standards which were transcribed in vitro. A total of 60 plasma of HIV infected patients were measured by TMA and Cobas Amplicor HIV-1 Monitor test to observe the positive rate. The correlation and concordance of the above two technologies were investigated by linear regression and Bland-Altman analysis. Results: TMA system was established successfully and HIV RNA transcribed standards at concentration of equal or more than 10 copies/mL could be detected by TMA technology. Among 60 samples of plasma from HIV infected patients, 46 were positively detected and 12 were negatively amplified by both TMA and Cobas reagents; 2 samples were positively tested by Cobas reagent but negatively tested by TMA system. The concordance rate of the two methods was 97.1% and the difference of positive detection rate between the two methods was not statistically significant (P>0.05). Linear regression was used for 46 samples which were positively detected by both TMA and Cobas reagents and showed an excellent correlation between the two reagents (r=0.997, P<0.001). Bland-Altma analysis revealed that the mean different value of HIV RNA levels for denary logarithm was 0.02. Forty-four samples were included in 95% of credibility interval of concordance. Conclusion: TMA system has the potential of high sensitivity. TMA and real-time RT-PCR keep an excellent correlation and consistency in detecting HIV RNA.
Aberl, A; Coelhan, M
2013-01-01
Sulfites are routinely added as preservatives and antioxidants in wine production. By law, the total sulfur dioxide content in wine is restricted and therefore must be monitored. Currently, the method of choice for determining the total content of sulfur dioxide in wine is the optimised Monier-Williams method, which is time consuming and laborious. The headspace gas chromatographic method described in this study offers a fast and reliable alternative method for the detection and quantification of the sulfur dioxide content in wine. The analysis was performed using an automatic headspace injection sampler, coupled with a gas chromatograph and an electron capture detector. The method is based on the formation of gaseous sulfur dioxide subsequent to acidification and heating of the sample. In addition to free sulfur dioxide, reversibly bound sulfur dioxide in carbonyl compounds, such as acetaldehyde, was also measured with this method. A total of 20 wine samples produced using diverse grape varieties and vintages of varied provenance were analysed using the new method. For reference and comparison purposes, 10 of the results obtained by the proposed method were compared with those acquired by the optimised Monier-Williams method. Overall, the results from the headspace analysis showed good correlation (R = 0.9985) when compared with the conventional method. This new method requires minimal sample preparation and is simple to perform, and the analysis can also be completed within a short period of time.
Autonomous acoustic recorders reveal complex patterns in avian detection probability
Thompson, Sarah J.; Handel, Colleen M.; McNew, Lance B.
2017-01-01
Avian point‐count surveys are typically designed to occur during periods when birds are consistently active and singing, but seasonal and diurnal patterns of detection probability are often not well understood and may vary regionally or between years. We deployed autonomous acoustic recorders to assess how avian availability for detection (i.e., the probability that a bird signals its presence during a recording) varied during the breeding season with time of day, date, and weather‐related variables at multiple subarctic tundra sites in Alaska, USA, 2013–2014. A single observer processed 2,692 10‐minute recordings across 11 site‐years. We used time‐removal methods to assess availability and used generalized additive models to examine patterns of detectability (joint probability of presence, availability, and detection) for 16 common species. Despite lack of distinct dawn or dusk, most species displayed circadian vocalization patterns, with detection rates generally peaking between 0800 hours and 1200 hours but remaining high as late as 2000 hours for some species. Between 2200 hours and 0500 hours, most species’ detection rates dropped to near 0, signaling a distinctive rest period. Detectability dropped sharply for most species in early July. For all species considered, time‐removal analysis indicated nearly 100% likelihood of detection during a 10‐minute recording conducted in June, between 0500 hours and 2000 hours. This indicates that non‐detections during appropriate survey times and dates were attributable to the species’ absence or that silent birds were unlikely to initiate singing during a 10‐minute interval, whereas vocally active birds were singing very frequently. Systematic recordings revealed a gradient of species’ presence at each site, from ubiquitous to incidental. Although the total number of species detected at a site ranged from 16 to 27, we detected only 4 to 15 species on ≥5% of the site's recordings. Recordings provided an unusually detailed and consistent dataset that allowed us to identify, among other things, appropriate survey dates and times for species breeding at northern latitudes. Our results also indicated that more recordings of shorter duration (1–4 min) may be most efficient for detecting passerines.
Fischer, Christoph; Domer, Benno; Wibmer, Thomas; Penzel, Thomas
2017-03-01
Photoplethysmography has been used in a wide range of medical devices for measuring oxygen saturation, cardiac output, assessing autonomic function, and detecting peripheral vascular disease. Artifacts can render the photoplethysmogram (PPG) useless. Thus, algorithms capable of identifying artifacts are critically important. However, the published PPG algorithms are limited in algorithm and study design. Therefore, the authors developed a novel embedded algorithm for real-time pulse waveform (PWF) segmentation and artifact detection based on a contour analysis in the time domain. This paper provides an overview about PWF and artifact classifications, presents the developed PWF analysis, and demonstrates the implementation on a 32-bit ARM core microcontroller. The PWF analysis was validated with data records from 63 subjects acquired in a sleep laboratory, ergometry laboratory, and intensive care unit in equal parts. The output of the algorithm was compared with harmonized experts' annotations of the PPG with a total duration of 31.5 h. The algorithm achieved a beat-to-beat comparison sensitivity of 99.6%, specificity of 90.5%, precision of 98.5%, and accuracy of 98.3%. The interrater agreement expressed as Cohen's kappa coefficient was 0.927 and as F-measure was 0.990. In conclusion, the PWF analysis seems to be a suitable method for PPG signal quality determination, real-time annotation, data compression, and calculation of additional pulse wave metrics such as amplitude, duration, and rise time.
NASA Astrophysics Data System (ADS)
Kong, Xirui; Fu, Zhilong; Que, Huiying; Fan, Yanwei; Chen, Zhaoyang; He, Chengfa
2018-05-01
The LiMgPO4: Tb, B ceramic disc is successfully synthesized via improved sintering method which enables the disc sample to have two flat and smooth surfaces. It is worth mentioning that the OSL signal intensity of LiMgPO4: Tb, B disc attenuates much faster than that of commercial Al2O3: C. It costs only 1 s to reduce the intensity to 10%, but the Al2O3:C needs more than 40 s to finish it. Some essential OSL properties related to the dose detection method of this sample also have been systematically investigated. Although the dose-response cure would have better linearity with longer recording time, extended recording time (≥6 s) will not make any contribution to the linearity of the curve. If the bleaching time is more than 35 s, the residue created by previous detection (high dose of 10 Gy) would do almost no influence (with a positive deviation lower than 5.59%) on next lower-dose detection (0.1 Gy). The material would reach its service life when the total-ionizing dose runs up to 30 k Gy. Therefore, the LiMgPO4: Tb, B ceramic material is a potential candidate for real-time dose monitoring with optical fiber telemetering technology.
NASA Astrophysics Data System (ADS)
Korneta, Wojciech; Gomes, Iacyel
2017-11-01
Traditional bistable sensors use external bias signal to drive its response between states and their detection strategy is based on the output power spectral density or the residence time difference (RTD) in two sensor states. Recently, the noise activated nonlinear dynamic sensors driven only by noise based on RTD technique have been proposed. Here, we present experimental results of dc voltage measurements by noise-driven bistable sensor based on electronic Chua's circuit operating in a chaotic regime where two single scroll attractors coexist. The output of the sensor is quantified by the proportion of the time the sensor stays in one state to the total observation time and by the spike-count rate with spikes defined by crossings between attractors. The relationship between the stimuli and particular observable for different noise intensities is obtained, the usefulness of each coding scheme is discussed, and the optimal noise intensity for detection is indicated. It is shown that the obtained relationship is the same for any observation time when population coding is used. The optimal time window for both detection and the number of units in population coding is found. Our results may be useful for analyses and understanding of the neural activity and in designing bistable storage elements at length scales where thermal fluctuations drastically increase and the effect of noise must be taken into consideration.
Whole-bacterium SELEX of DNA aptamers for rapid detection of E.coli O157:H7 using a QCM sensor.
Yu, Xiaofan; Chen, Fang; Wang, Ronghui; Li, Yanbin
2018-01-20
The rapid detection of foodborne pathogens is critical to ensure food safety. The objective of this study is to select aptamers specifically bound to Escherichia coli O157:H7 using the whole-bacterium SELEX (Systematic Evolution of Ligands by Exponential Enrichment) and apply the selected aptamer to a QCM (quartz crystal microbalance) sensor for rapid and sensitive detection of target bacteria. A total of 19 rounds of selection against live E. coli O157:H7 and 6 rounds of counter selection against a mixture of Staphylococcus aureus, Listeria monocytogenes, and Salmonella Typhimurium, were performed. The aptamer pool from the last round was cloned and sequenced. One sequence S1 that appeared 16 times was characterized and a dissociation constant (K d ) of 10.30nM was obtained. Subsequently, a QCM aptasensor was developed for the rapid detection of E. coli O157:H7. The limit of detection (LOD) and the detection time of the aptasensor was determined to be 1.46×10 3 CFU/ml and 50min, respectively. This study demonstrated that the ssDNA aptamer selected by the whole-bacterium SELEX possessed higher sensitivity than previous work and the potential use of the constructed QCM aptasensor in rapid screening of foodborne pathogens. Copyright © 2017 Elsevier B.V. All rights reserved.
Sertel Şelale, Denİz; Uzun, Meltem
2018-01-01
Inexpensive, rapid, and reliable tests for detecting the presence and drug susceptibility of Mycobacterium tuberculosis complex (MTBC) are urgently needed to control the transmission of tuberculosis. In this study, we aimed to assess the accuracy and speed of the microscopic-observation drug susceptibility (MODS) assay in the identification of MTBC and detection of multidrug resistance. Sputum samples from patients suspected to have tuberculosis were simultaneously tested with MODS and conventional culture [Löwenstein-Jensen (LJ) culture, BACTEC MGIT™ 960 (MGIT) system], and drug susceptibility testing (MGIT system) methods. A total of 331 sputum samples were analyzed. Sensitivity and specificity of MODS assay for detection of MTBC strains were 96% and 98.8%, respectively. MODS assay detected multidrug resistant MTBC isolates with 92.3% sensitivity and 96.6% specificity. Median time to culture positivity was similar for MGIT (8 days) and MODS culture (8 days), but was significantly longer with LJ culture (20 days) (p < 0.0001 for both comparisons). Median time to availability of the susceptibility results was significantly (p < 0.0001) shorter with MODS assay (8 days) than MGIT system (20 days). In conclusion, MODS is an inexpensive and rapid test with good performance characteristics for direct diagnosis of tuberculosis and detection of multidrug resistance. © 2017 APMIS. Published by John Wiley & Sons Ltd.
Wang, Hua; Yang, Shao-hui; Yang, Jing-ping; Lv, Ya-min; Zhao, Xing; Pang, Ji-liang
2014-11-01
It is important to understand the effects of temporal changes in microbial communities in the acidic soils of tea orchards with different fertilizers. A field experiment involving organic fertilizer (OF), chemical fertilizer (CF), and unfertilized control (CK) treatments was arranged to analyze the temporal changes in the bacterial and archaeal communities at bimonthly intervals based on the 16S ribosomal RNA (rRNA) gene using terminal restriction fragment length polymorphism (T-RFLP) profiling. The abundances of total bacteria, total archaea, and selected functional genes (bacterial and archaeal amoA, bacterial narG, nirK, nirS, and nosZ) were determined by quantitative polymerase chain reaction (qPCR). The results indicate that the structures of bacterial and archaeal communities varied significantly with time and fertilization based on changes in the relative abundance of dominant T-RFs. The abundancy of the detected genes changed with time. The total bacteria, total archaea, and archaeal amoA were less abundant in July. The bacterial amoA and denitrifying genes were less abundant in September, except the nirK gene. The OF treatment increased the abundance of the observed genes, while the CF treatment had little influence on them. The soil temperature significantly affected the bacterial and archaeal community structures. The soil moisture was significantly correlated with the abundance of denitrifying genes. Of the soil chemical properties, soil organic carbon was the most important factor and was significantly correlated with the abundance of the detected genes, except the nirK gene. Overall, this study demonstrated the effects of both temporal alteration and organic fertilizer on the structures of microbial communities and the abundance of genes involved in the nitrogen cycle.
Wang, Hua; Yang, Shao-hui; Yang, Jing-ping; Lv, Ya-min; Zhao, Xing; Pang, Ji-liang
2014-01-01
It is important to understand the effects of temporal changes in microbial communities in the acidic soils of tea orchards with different fertilizers. A field experiment involving organic fertilizer (OF), chemical fertilizer (CF), and unfertilized control (CK) treatments was arranged to analyze the temporal changes in the bacterial and archaeal communities at bimonthly intervals based on the 16S ribosomal RNA (rRNA) gene using terminal restriction fragment length polymorphism (T-RFLP) profiling. The abundances of total bacteria, total archaea, and selected functional genes (bacterial and archaeal amoA, bacterial narG, nirK, nirS, and nosZ) were determined by quantitative polymerase chain reaction (qPCR). The results indicate that the structures of bacterial and archaeal communities varied significantly with time and fertilization based on changes in the relative abundance of dominant T-RFs. The abundancy of the detected genes changed with time. The total bacteria, total archaea, and archaeal amoA were less abundant in July. The bacterial amoA and denitrifying genes were less abundant in September, except the nirK gene. The OF treatment increased the abundance of the observed genes, while the CF treatment had little influence on them. The soil temperature significantly affected the bacterial and archaeal community structures. The soil moisture was significantly correlated with the abundance of denitrifying genes. Of the soil chemical properties, soil organic carbon was the most important factor and was significantly correlated with the abundance of the detected genes, except the nirK gene. Overall, this study demonstrated the effects of both temporal alteration and organic fertilizer on the structures of microbial communities and the abundance of genes involved in the nitrogen cycle. PMID:25367788
Detection of adulterants in honey using a portable Raman Spectrometer
NASA Astrophysics Data System (ADS)
Garcia, Kenneth Leigh
Food adulteration is a growing problem worldwide. In the United States over half of honey consumed is provided with imported products as total domestic production of honey is unable to meet the demand. As pure, natural honey is a labor intensive, relatively expensive product it is a prime target for adulteration with less expensive sweeteners. Previously published work describes the detection of these adulterants in a strict laboratory environment with time consuming techniques and delicate instrumentation. Experiments confirm that adulterants such as high fructose corn syrup and rice malt syrup can be detected in honey using Raman Spectroscopy and portable equipment. When laser light is applied to the products, the result is a Raman signal of inelastically scattered photons representing the fingerprints of the various molecules. When this signal is detected and stored in a laptop computer it can be analyzed for characteristics peculiar to honey and to the adulterants.
Prakash, Batah Kunalan; Low, Van Lun; Vinnie-Siow, Wei Yin; Tan, Tiong Kai; Lim, Yvonne Ai-Lian; Morvarid, Akhavan Rezaei; AbuBakar, Sazaly; Sofian-Azirun, Mohd
2018-05-12
Canine babesiosis is an emerging tick-borne disease with a worldwide distribution, including Malaysia. While the prevalence of Babesia has been documented from dogs in Malaysia, occurrence of Babesia has been relatively little studied in their tick vectors. Accordingly, a total of 240 dogs and 140 Rhipicephalus sanguineus sensu lato (s.l.) (Acari: Ixodidae) ticks from Malaysia were molecularly screened for the presence of Babesia protozoa in the present study. Babesia gibsoni was only detected in ticks (1.4%), whereas Babesia vogeli was detected in both ticks (1.4%) and dogs (2.1%). This study highlights the detection of B. gibsoni and B. vogeli for the first time, in both adult and nymphal stages of R. sanguineus s.l. in Malaysia, suggesting the potential role of this tick species in transmitting canine babesiosis.
Patient-Specific Early Seizure Detection from Scalp EEG
Minasyan, Georgiy R.; Chatten, John B.; Chatten, Martha Jane; Harner, Richard N.
2010-01-01
Objective Develop a method for automatic detection of seizures prior to or immediately after clinical onset using features derived from scalp EEG. Methods This detection method is patient-specific. It uses recurrent neural networks and a variety of input features. For each patient we trained and optimized the detection algorithm for two cases: 1) during the period immediately preceding seizure onset, and 2) during the period immediately following seizure onset. Continuous scalp EEG recordings (duration 15 – 62 h, median 25 h) from 25 patients, including a total of 86 seizures, were used in this study. Results Pre-onset detection was successful in 14 of the 25 patients. For these 14 patients, all of the testing seizures were detected prior to seizure onset with a median pre-onset time of 51 sec and false positive rate was 0.06/h. Post-onset detection had 100% sensitivity, 0.023/hr false positive rate and median delay of 4 sec after onset. Conclusions The unique results of this study relate to pre-onset detection. Significance Our results suggest that reliable pre-onset seizure detection may be achievable for a significant subset of epilepsy patients without use of invasive electrodes. PMID:20461014
2011-07-01
impact on overall probe performance, including spatial resolution, energy resolution and timing resolution. We will show that 1 mm3 voxels will...ring, description of a strategy to remove scattered events, followed by characterization of impact of timing properties of the probe. In summary, the...described by the total distance d¼d1+d2 and a¼ d1=ðd1þd2Þ. We also want to account for impact angles, y1 and y2, defined versus line perpendicular to
Using large volume samplers for the monitoring of particle bound micro pollutants in rivers
NASA Astrophysics Data System (ADS)
Kittlaus, Steffen; Fuchs, Stephan
2015-04-01
The requirements of the WFD as well as substance emission modelling at the river basin scale require stable monitoring data for micro pollutants. The monitoring concepts applied by the local authorities as well as by many scientists use single sampling techniques. Samples from water bodies are usually taken in volumes of about one litre and depending on predetermined time steps or through discharge thresholds. For predominantly particle bound micro pollutants the small sample size of about one litre results in a very small amount of suspended particles. To measure micro pollutant concentrations in these samples is demanding and results in a high uncertainty of the measured concentrations, if the concentration is above the detection limit in the first place. In many monitoring programs most of the measured values were below the detection limit. This results in a high uncertainty if river loads were calculated from these data sets. The authors propose a different approach to gain stable concentration values for particle bound micro pollutants from river monitoring: A mixed sample of about 1000 L was pumped in a tank with a dirty-water pump. The sampling usually is done discharge dependant by using a gauge signal as input for the control unit. After the discharge event is over or the tank is fully filled, the suspended solids settle in the tank for 2 days. After this time a clear separation of water and solids can be shown. A sample (1 L) from the water phase and the total mass of the settled solids (about 10 L) are taken to the laboratory for analysis. While the micro pollutants can't hardly be detected in the water phase, the signal from the sediment is high above the detection limit, thus certain and very stable. From the pollutant concentration in the solid phase and the total tank volume the initial pollutant concentration in the sample can be calculated. If the concentration in the water phase is detectable, it can be used to correct the total load. This relatively low cost approach (less costs for analysis because of small sample number) allows to quantify the pollutant load, to derive dissolved-solid partition coefficients and to quantify the pollutant load in different particle size classes.
Granados-Lieberman, David; Valtierra-Rodriguez, Martin; Morales-Hernandez, Luis A; Romero-Troncoso, Rene J; Osornio-Rios, Roque A
2013-04-25
Power quality disturbance (PQD) monitoring has become an important issue due to the growing number of disturbing loads connected to the power line and to the susceptibility of certain loads to their presence. In any real power system, there are multiple sources of several disturbances which can have different magnitudes and appear at different times. In order to avoid equipment damage and estimate the damage severity, they have to be detected, classified, and quantified. In this work, a smart sensor for detection, classification, and quantification of PQD is proposed. First, the Hilbert transform (HT) is used as detection technique; then, the classification of the envelope of a PQD obtained through HT is carried out by a feed forward neural network (FFNN). Finally, the root mean square voltage (Vrms), peak voltage (Vpeak), crest factor (CF), and total harmonic distortion (THD) indices calculated through HT and Parseval's theorem as well as an instantaneous exponential time constant quantify the PQD according to the disturbance presented. The aforementioned methodology is processed online using digital hardware signal processing based on field programmable gate array (FPGA). Besides, the proposed smart sensor performance is validated and tested through synthetic signals and under real operating conditions, respectively.
Khandelwal, Siddhartha; Wickstrom, Nicholas
2016-12-01
Detecting gait events is the key to many gait analysis applications that would benefit from continuous monitoring or long-term analysis. Most gait event detection algorithms using wearable sensors that offer a potential for use in daily living have been developed from data collected in controlled indoor experiments. However, for real-word applications, it is essential that the analysis is carried out in humans' natural environment; that involves different gait speeds, changing walking terrains, varying surface inclinations and regular turns among other factors. Existing domain knowledge in the form of principles or underlying fundamental gait relationships can be utilized to drive and support the data analysis in order to develop robust algorithms that can tackle real-world challenges in gait analysis. This paper presents a novel approach that exhibits how domain knowledge about human gait can be incorporated into time-frequency analysis to detect gait events from long-term accelerometer signals. The accuracy and robustness of the proposed algorithm are validated by experiments done in indoor and outdoor environments with approximately 93 600 gait events in total. The proposed algorithm exhibits consistently high performance scores across all datasets in both, indoor and outdoor environments.
Detectability of the first cosmic explosions
NASA Astrophysics Data System (ADS)
de Souza, R. S.; Ishida, E. E. O.; Johnson, J. L.; Whalen, D. J.; Mesinger, A.
2013-12-01
We present a fully self-consistent simulation of a synthetic survey of the furthermost cosmic explosions. The appearance of the first generation of stars (Population III) in the Universe represents a critical point during cosmic evolution, signalling the end of the dark ages, a period of absence of light sources. Despite their importance, there is no confirmed detection of Population III stars so far. A fraction of these primordial stars are expected to die as pair-instability supernovae (PISNe), and should be bright enough to be observed up to a few hundred million years after the big bang. While the quest for Population III stars continues, detailed theoretical models and computer simulations serve as a testbed for their observability. With the upcoming near-infrared missions, estimates of the feasibility of detecting PISNe are not only timely but imperative. To address this problem, we combine state-of-the-art cosmological and radiative simulations into a complete and self-consistent framework, which includes detailed features of the observational process. We show that a dedicated observational strategy using ≲ 8 per cent of the total allocation time of the James Webb Space Telescope mission can provide us with up to ˜9-15 detectable PISNe per year.
Taniuchi, Mami; Verweij, Jaco J.; Noor, Zannatun; Sobuz, Shihab U.; van Lieshout, Lisette; Petri, William A.; Haque, Rashidul; Houpt, Eric R.
2011-01-01
Polymerase chain reaction (PCR) assays for intestinal parasites are increasingly being used on fecal DNA samples for enhanced specificity and sensitivity of detection. Comparison of these tests against microscopy and copro-antigen detection has been favorable, and substitution of PCR-based assays for the ova and parasite stool examination is a foreseeable goal for the near future. One challenge is the diverse list of protozoan and helminth parasites. Several existing real-time PCR assays for the major intestinal parasites—Cryptosporidium spp., Giardia intestinalis, Entamoeba histolytica, Ancylostoma duodenale, Ascaris lumbricoides, Necator americanus, and Strongyloides stercoralis—were adapted into a high throughput protocol. The assay involves two multiplex PCR reactions, one with specific primers for the protozoa and one with specific primers for the helminths, after which PCR products are hybridized to beads linked to internal oligonucleotide probes and detected on a Luminex platform. When compared with the parent multiplex real-time PCR assays, this multiplex PCR-bead assay afforded between 83% and 100% sensitivity and specificity on a total of 319 clinical specimens. In conclusion, this multiplex PCR-bead protocol provides a sensitive diagnostic screen for a large panel of intestinal parasites. PMID:21292910
Li, Chuanliang; Wu, Yingfa; Qiu, Xuanbing; Wei, Jilin; Deng, Lunhua
2017-05-01
Wavelength modulation spectroscopy (WMS) combined with a multipass absorption cell has been used to measure a weak absorption line of carbon monoxide (CO) at 1.578 µm. A 0.95m Herriott-type cell provides an effective absorption path length of 55.1 m. The WMS signals from the first and second harmonic output of a lock-in amplifier (WMS-1 f and 2 f, respectively) agree with the Beer-Lambert law, especially at low concentrations. After boxcar averaging, the minimum detection limit achieved is 4.3 ppm for a measurement time of 0.125 s. The corresponding normalized detection limit is 84 ppm m Hz -1/2 . If the integrated time is increased to 88 s, the minimum detectable limit of CO can reach to 0.29 ppm based on an Allan variation analysis. The pressure-dependent relationship is validated after accounting for the pressure factor in data processing. Finally, a linear correlation between the WMS-2 f amplitudes and gas concentrations is obtained at concentration ratios less than 15.5%, and the accuracy is better than 92% at total pressure less than 62.7 Torr.
A simple method to measure critical angles for high-sensitivity differential refractometry.
Zilio, S C
2012-01-16
A total internal reflection-based differencial refractometer, capable of measuring the real and imaginary parts of the complex refractive index in real time, is presented. The device takes advantage of the phase difference acquired by s- and p-polarized light to generate an easily detectable minimum at the reflected profile. The method allows to sensitively measuring transparent and turbid liquid samples.
Comprehensive Analyzer for Biogenic Volatile Organic Compounds Detected as Total Ozone Reactivity
NASA Astrophysics Data System (ADS)
Matsumoto, J.
2011-12-01
Volatile organic compounds, VOCs, are emitted from various sources into the atmosphere. Through the reactions of VOCs with atmospheric radicals (eg. daytime OH, nighttime NO3, and all-day O3), formation of photochemical oxidants and secondary organic aerosols, SOA, are important. To investigate the mechanisms of reactions in the atmosphere and to control such secondary products effectively, it is essential to capture the behavior of VOC emission with the radical reactivity of VOCs considered. Recently, in addition to OH reactions of anthropogenic VOCs, SOA formation due to ozonolysis of biogenic VOCs (BVOCs) is one of the hottest topics in the atmospheric chemistry. It is difficult to analyze all the species individually due to the great number of VOCs. In this study, a comprehensive tool for capturing the total reactivity of BVOCs with ozone is realized utilizing a chemiluminescence ozone analyzer. A sensitive and fast-response ozone analyzer was developed based on an existing chemiluminescent NO analyzer (CLD). The CLD-O3 analyzer was used to monitor the fast variation of O3 in the sample of the VOC + O3 experiment. When O3 was added to the VOC sample, the reduction of O3 due to VOC was monitored and the O3 reactivity RO3 was determined with the reaction time considered. Dependence of the response of analyzer on the reaction time and the reactivity of sample was examined and confirmed as reasonable. As a result, VOCs can be detected at the level of ppbv (as limonene, S/N = 3). The detection limit of RO3 was 0.0002 s-1. For the test of ozone reactivity measurement of BVOCs emitted from the real vegetation, variation of ozone reactivity was significantly observed after the nursery was put into a closed chamber. In addition, just after the leaves of the plant were physically stimulated, observed reactivity increased. It was experimentally confirmed that stimulus to the leaves of the plant resulted in the increase of total BVOC emission. Consequently, it was confirmed that the analyzer be useful to investigate the real-time analysis of BVOC emission from the vegetation at the level of ppbv.
[Malignant tumors of the female genital track in the elderly].
Gottwald, Leszek; Akoel, Kindah Mo; Wójcik-Krowiranda, Katarzyna; Bieńkiewicz, Andrzej
2003-09-01
In senium the increase in the incidence of most malignant neoplasms, as well as gynecological cancers is found. In this period of life the vast number of women do not apply for the preventive and follow-up examinations, which increases the number of malignant diseases diagnosed at advanced clinical stages. The coexisting another diseases often limits the possibility of the operative treatment in those cases. To assess the profile of malignant tumors of the genital tract and their treatment in women above 70 year old. 61 women aged from 71 yrs. to 88 yrs. treated operatively between 1997-2001 due to gynecological cancers were included into the study. The structure and detectability of the neoplasms, as well as the type of performed surgical procedures were analysed. 30 endometrial cancers (49.2%), 16 ovarian cancers (26.2%), 14 vulvar cancers (22.9%) and 1 cervical cancer were diagnosed and surgically treated. The endometrial cancer stage I was detected in 18 cases, stage II in 4 cases and stage III in 8 cases. In each case the radical operation was done (total hysterectomy, lymphadenectomy and appendectomy). The ovarian cancer stage I was detected in 3 cases, stage II in 2 cases, stage III in 5 cases, and stage IV in 6 cases. Only in 5 cases out of this group the radical surgery was performed (total hysterectomy, omentectomy and appendectomy). The vulvar cancer stage I was detected in 2 cases, stage II in 11 cases, and FIGO stage III in 4 cases. In each of these women the vulva and bilateral inguinal lymph nodes were resected, and in 2 cases additionally at the same time the Miles operation was performed. The cervical cancer clinical stage I was detected, and the Wertheim operation was performed. The most often diagnosed malignant neoplasm in women above 70 yrs. was the endometrial cancer. The worst first-time diagnosis structure was observed in the ovarian cancer, what significantly decreased the ability of surgical treatment in this group.
Church, Deirdre L; Lloyd, Tracie; Larios, Oscar; Gregson, Daniel B
2018-03-01
Diagnosis of bacterial pharyngitis is confirmed by detection of group A Streptococcus (GAS) in patient throat samples. Testing of throat samples has historically relied on culture, but new molecular methods allow much faster test turnaround time (i.e., same day versus 48 to 72 h for culture). Our laboratory uses the Hologic GAS Direct (GASD) assay for screening more than 125,000 throat samples per year. Simplexa GAS Direct is a new real-time quantitative PCR (qPCR) assay that does not require initial DNA extraction. Performance of Simplexa qPCR was compared to GASD. A total of 289 throat swabs were collected from patients attending ambulatory clinics in Calgary, Alberta, Canada. A total of 60 (20.8%) of the samples were initially GAS positive by either method: 54 by both methods, 4 by Simplex qPCR alone, and 2 by GASD alone. An in-house PCR using a unique GAS primer set was used to resolve the 6 discrepant results. Overall, GASD compared to Simplexa qPCR had a sensitivity, specificity, positive predictive value, and negative predictive value of 93.1% versus 100%, 100% versus 100%, 100% versus 100%, and 98.31% versus 100%, respectively. Implementation of Simplexa qPCR in our laboratory setting would cost more but allow the high sample volume to be reported in half the time and save 0.62 medical laboratory technician (MLT) full-time equivalent (FTE). In comparison to culture, the implementation of Simplexa qPCR would save 2.79 medical laboratory assistant (MLA) FTE plus 0.94 MLT FTE. Simplexa qPCR has improved performance and diagnostic efficiency in a high-volume laboratory compared to GASD for GAS detection in throat swabs. Copyright © 2018 American Society for Microbiology.
Mau, David P.; Ziegler, Andrew C.; Porter, Stephen D.; Pope, Larry M.
2004-01-01
Surface water in the Lake Olathe watershed, located in northeast Kansas, was sampled from June 2000 through December 2002 to characterize water-quality conditions in relation to physical properties, major ions, sediment, nutrients, selected trace elements, selected pesticides, fecal indicator bacteria, phytoplankton, and taste-and-odor compounds. In addition, two continuous real-time water-quality monitors were operated?one in Cedar Creek at Highway 56, the main tributary to Lake Olathe, and one in Lake Olathe, a supplemental domestic water supply and recreational resource for the city of Olathe. Median concentrations of dissolved and total forms of nitrogen and phosphorus in samples from Cedar Creek were larger than in samples from Lake Olathe, indicating that nutrients in the watershed were transported to Lake Olathe by Cedar Creek from June 2000 through December 2002. Increased concentrations of total phosphorus in samples from the hypolimnion of Lake Olathe compared to the epilimnion indicated that release of total phosphorus from bottom sediments occurred in the lake. Of the 50 pesticides analyzed in water samples from Cedar Creek and Lake Olathe, 10 pesticides were detected at concentrations greater than 0.01 microgram per liter in samples from Cedar Creek, and 9 pesticides were detected at concentrations greater than 0.01 microgram per liter in Lake Olathe, including four herbicides with concentrations exceeding 1.0 microgram per liter. Atrazine was detected at larger concentrations than any other pesticide in samples from both Cedar Creek and Lake Olathe during 2001 and 2002. Concentrations did not exceed the U.S. Environmental Protection Agency drinking-water annual average criterion of 3.0 micrograms per liter; however, concentrations in single samples were larger than 3.0 micrograms per liter. Regression analysis was used to assist in the estimation of sediment and chemical loads and yields. The estimated mean orthophosphate load for 2001 and 2002 represented 29 percent of the total phosphorus load to Lake Olathe. Estimated yields to Lake Olathe of both total nitrogen and total phosphorus, 13.0 and 1.1 pounds per acre per year, respectively, were consistent with mixed agricultural land use occurring in the watershed. Concentrations of fecal coliform bacteria samples from Lake Olathe were less than both primary and secondary single-sample criteria for recreational water in Kansas in place at the time of sampling. Sufficient samples were not collected to compare to the December 2003 Kansas Department of Health and Environment criteria, but single-sample Escherichia coli samples collected from Cedar Creek during storm runoff exceeded 2,000 colonies per 100 milliliters of water (former secondary recreation water-quality criterion for fecal coliform bacteria) in four of the seven samples collected. Water from Cedar Creek and Lake Olathe was analyzed in 2002 by enzyme-linked immunosorbent assay for microcystin-LR, a toxic algal compound. Concentrations of microcystin-LR in Lake Olathe during 2002 ranged from less than 0.1 to 0.41 microgram per liter, which is not considered a significant health risk according to guidelines published by the World Health Organization. Regression models were developed for four taste-and-odor phytoplankton species detected frequently in Lake Olathe? Melosira granulata, Anabaena, Oscillatoria, and Cryptomonas. The coefficient of determinations, R2, ranged from 0.64 to 0.89, and p-values ranged from less than 0.001 to 0.014, indicating a statistically significant relation with lake-residence time, specific conductance, turbidity, Secchi transparency depth, real-time continuous fluorescence, and total ammonia plus organic nitrogen as nitrogen. Actinomycetes, filamentous bacteria that are known producers of geosmin and 2-methylisoborneol (MIB), were sampled and analyzed in 2002 in water from Cedar Creek and Lake Olathe. In Lake Olathe, actinomycetes concentrations rang
Shen, Wentao; Tuo, Decai; Yan, Pu; Li, Xiaoying; Zhou, Peng
2014-01-01
Papaya leaf distortion mosaic virus (PLDMV) can infect transgenic papaya resistant to a related pathogen, Papaya ringspot virus (PRSV), posing a substantial threat to papaya production in China. Current detection methods, however, are unable to be used for rapid detection in the field. Here, a reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for the detection of PLDMV, using a set of four RT-LAMP primers designed based on the conserved sequence of PLDMV CP. The RT-LAMP method detected specifically PLDMV and was highly sensitive, with a detection limit of 1.32×10(-6) μg of total RNA per reaction. Indeed, the reaction was 10 times more sensitive than one-step RT-PCR, while also requiring significantly less time and equipment. The effectiveness of RT-LAMP and one-step RT-PCR in detecting the virus were compared using 90 field samples of non-transgenic papaya and 90 field samples of commercialized PRSV-resistant transgenic papaya from Hainan Island. None of the non-transgenic papaya tested positive for PLDMV using either method. In contrast, 19 of the commercialized PRSV-resistant transgenic papaya samples tested positive by RT-LAMP assay, and 6 of those tested negative by RT-PCR. Therefore, the PLDMV-specific RT-LAMP is a simple, rapid, sensitive, and cost-effective tool in the field diagnosis and control of PLDMV. Copyright © 2013 Elsevier B.V. All rights reserved.
Pan, Yang; Wang, Ying; Li, Aimin; Xu, Bin; Xian, Qiming; Shuang, Chendong; Shi, Peng; Zhou, Qing
2017-04-01
Recently, 13 new polar phenolic chlorinated and brominated disinfection byproducts (Cl- and Br-DBPs) were identified and quantified in simulated chlorinated drinking water by adopting product ion scan, precursor ion scan, and multiple reaction monitoring (MRM) analyses using ultra performance liquid chromatography/electrospray ionization-triple quadrupole mass spectrometry (UPLC/ESI-tqMS). The 13 new DBPs have been drawing increasing concern not only because they possess significantly higher growth inhibition, developmental toxicity, and chronic cytotoxicity than commonly known aliphatic DBPs, but also because they act as intermediate DBPs that can decompose to form the U.S. EPA regulated DBPs. In this study, through MS parameter optimization of the UPLC/ESI-tqMS MRM analysis, the instrument detection and quantitation limits of the 13 new DBPs were substantially lowered to 0.42-6.44 and 1.35-16.51 μg/L, respectively. The total levels of the 13 new DBPs formed in chlorination were much higher than those formed in chloramination within a contact time of 3 d. In chlorination, the 13 new DBPs formed quickly and decomposed rapidly, and their total concentration kept on decreasing with contact time. In chloramination, the levels of the dominant species (i.e., trihalo-phenols) firstly increased and then decreased with contact time, whereas the levels of the other new DBPs were relatively low and kept on increasing with contact time. An increasing of pH from 6.0 to 9.0 decreased the formation of the 13 new DBPs by 57.8% and 62.3% in chlorination and chloramination, respectively. Gallic acid was found to be present in various simulated and real source water samples and was demonstrated to be a precursor of the 13 new DBPs with elucidated formation pathways. Furthermore, 12 of the 13 new DBPs were detected in 16 tap water samples obtained from major cities in East China, at total levels from 9.5 to 329.8 ng/L. The concentrations of the new DBPs were higher in samples with source waters containing higher bromide levels. Ozone-activated carbon treatment prior to disinfection might reduce the formation of the new DBPs since it was effective in precursor reduction. Copyright © 2017 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hirvonen, Liisa M.; Le Marois, Alix; Suhling, Klaus, E-mail: klaus.suhling@kcl.ac.uk
We perform wide-field time-correlated single photon counting-based fluorescence lifetime imaging (FLIM) with a crossed delay line anode image intensifier, where the pulse propagation time yields the photon position. This microchannel plate-based detector was read out with conventional fast timing electronics and mounted on a fluorescence microscope with total internal reflection (TIR) illumination. The picosecond time resolution of this detection system combines low illumination intensity of microwatts with wide-field data collection. This is ideal for fluorescence lifetime imaging of cell membranes using TIR. We show that fluorescence lifetime images of living HeLa cells stained with membrane dye di-4-ANEPPDHQ exhibit a reducedmore » lifetime near the coverslip in TIR compared to epifluorescence FLIM.« less
Yusof, Mohammed F; Eltahir, Yassir M; Serhan, Wissam S; Hashem, Farouk M; Elsayed, Elsaeid A; Marzoug, Bahaaeldin A; Abdelazim, Assem Si; Bensalah, Oum Keltoum A; Al Muhairi, Salama S
2015-06-01
High seroprevalence of Middle East respiratory syndrome corona virus (MERS-CoV) in dromedary camels has been previously reported in United Arab Emirates (UAE). However, the molecular detection of the virus has never been reported before in UAE. Of the 7,803 nasal swabs tested in the epidemiological survey, MERS-CoV nucleic acid was detected by real-time PCR in a total of 126 (1.6 %) camels. Positive camels were detected at the borders with Saudi Arabia and Oman and in camels' slaughter houses. MERS-CoV partial sequences obtained from UAE camels were clustering with human- and camel-derived MERS-CoV sequences in the same geographic area. Results provide further evidence of MERS-CoV zoonosis.
On-site detection of packaged squid freshness
NASA Astrophysics Data System (ADS)
Ahmad, Noor Azizah; Heng, Lee Yook; Salam, Faridah; Hanifah, Sharina Abu
2018-04-01
The development of indicator label for detection of total volatile basic nitrogen (TVB-N) is described. Dye extract from edible plants containing anthocyanins was immobilized onto iota-carrageenan as polymer matrix. TVB-N detection worked based on pH increase as the basic deterioration volatile amines generated in the package headspace. Results showed that the indicator label has changed color from blue to green after 12 hours of storage at ambient conditions. The TVB-N value was 38.9648 mg /100 g which is exceeded of acceptability level for seafood products. The pH value of squid flesh has also increased during storage. The colour values of L * and a * negative increases while b* negative decrease with increasing storage time. The indicator label is potentially used as freshness indicator for squid at ambient conditions.
NASA Technical Reports Server (NTRS)
Ahearn, Michael F.; Mcfadden, Lucy A.; Feldman, Paul D.; Boehnhardt, Hermann; Rahe, Juergen; Festou, Michael; Brandt, John C.; Maran, Stephen P.; Niedner, Malcom B.; Smith, Andrew M.
1986-01-01
The IUE spectrophotometry of Comet P/Giacobini-Zinner was acquired in support of the International Cometary Explorer (ICE) mission. The abundances (or upper limits) of UV-active species were calculated. During the ICE encounter the H2O production rate was 3 times 10 to the 28th power/sec, + or - 50%, consistent with values derived from the ICE experiments. Comparison of the abundance of CO2(+) ions with the total electron density measured by the plasma electron experiment on ICE indicates a deficiency of ions relative to electrons indicating a population of ions not detected by remote sensing. The absence of detectable Mg(+) rules out this species as a possible ion of M/Q = 24 detected by the Ion Composition Instrument, part of the ICE complement of instruments.
Akram, Arifa; Islam, S M Rashedul; Munshi, Saif Ullah; Tabassum, Shahina
2018-05-16
Transmission of Hepatitis B Virus (HBV) usually occurs due to the transfusion of blood or blood products from chronic HBV (CHB) or occult HBV infected (OBI) patients. Besides serological tests e.g. HBsAg and anti-HBc (total), detection of HBV-DNA is necessary for the diagnosis of OBI patients. Different nucleic acid tests (NATs) including real-time-Polymerase Chain Reaction (qPCR) are used for the detect HBV-DNA. The NATs are expensive and require technical expertise which are barriers to introducing them in resource-limited settings. This study was undertaken to evaluate the use of Loop-Mediated Isothermal Amplification (LAMP) assay as an alternative to qPCR for the detection of HBV-DNA in CHB and potential OBI patients in resource-limited settings. Following the published protocols with some modifications, a LAMP assay was developed for detection of HBV-DNA by either using a heat block followed by detection in an agarose gel or using a qPCR thermocycler. The LAMP assay was applied to supernatant prepared from heat treated serum collected from CHB and potential OBI patients. HBV viral load in serum was measured by qPCR using a single step HBV-DNA quantification kit. Among 200 samples tested, qPCR was capable to detect HBV-DNA in 25.5% of cases, whereas LAMP assay detected HBV-DNA in 43.5% cases. The qPCR was able to detect 11 (9.16%) potential OBI cases, whereas LAMP assay identified HBV-DNA in 43 (35.83%) cases. In addition to tests for HBsAg and/or anti-HBc (total), detection of HBV-DNA by LAMP assay may aid in preventing post-transfusion HBV infection in resource-limited settings. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Motamedi, Marjan; Mirhendi, Hossein; Zomorodian, Kamiar; Khodadadi, Hossein; Kharazi, Mahboobeh; Ghasemi, Zeinab; Shidfar, Mohammad Reza; Makimura, Koichi
2017-10-01
Following our previous report on evaluation of the beta tubulin real-time PCR for detection of dermatophytosis, this study aimed to compare the real-time PCR assay with conventional methods for the clinical assessment of its diagnostic performance. Samples from a total of 853 patients with suspected dermatophyte lesions were subjected to direct examination (all samples), culture (499 samples) and real-time PCR (all samples). Fungal DNA was extracted directly from clinical samples using a conical steel bullet, followed by purification with a commercial kit and subjected to the Taq-Man probe-based real-time PCR. The study showed that among the 499 specimens for which all three methods were used, 156 (31.2%), 128 (25.6%) and 205 (41.0%) were found to be positive by direct microscopy, culture and real-time PCR respectively. Real-time PCR significantly increased the detection rate of dermatophytes compared with microscopy (288 vs 229) with 87% concordance between the two methods. The sensitivity, specificity, positive predictive value, and negative predictive value of the real-time PCR was 87.5%, 85%, 66.5% and 95.2% respectively. Although real-time PCR performed better on skin than on nail samples, it should not yet fully replace conventional diagnosis. © 2017 Blackwell Verlag GmbH.
Cyber situation awareness: modeling detection of cyber attacks with instance-based learning theory.
Dutt, Varun; Ahn, Young-Suk; Gonzalez, Cleotilde
2013-06-01
To determine the effects of an adversary's behavior on the defender's accurate and timely detection of network threats. Cyber attacks cause major work disruption. It is important to understand how a defender's behavior (experience and tolerance to threats), as well as adversarial behavior (attack strategy), might impact the detection of threats. In this article, we use cognitive modeling to make predictions regarding these factors. Different model types representing a defender, based on Instance-Based Learning Theory (IBLT), faced different adversarial behaviors. A defender's model was defined by experience of threats: threat-prone (90% threats and 10% nonthreats) and nonthreat-prone (10% threats and 90% nonthreats); and different tolerance levels to threats: risk-averse (model declares a cyber attack after perceiving one threat out of eight total) and risk-seeking (model declares a cyber attack after perceiving seven threats out of eight total). Adversarial behavior is simulated by considering different attack strategies: patient (threats occur late) and impatient (threats occur early). For an impatient strategy, risk-averse models with threat-prone experiences show improved detection compared with risk-seeking models with nonthreat-prone experiences; however, the same is not true for a patient strategy. Based upon model predictions, a defender's prior threat experiences and his or her tolerance to threats are likely to predict detection accuracy; but considering the nature of adversarial behavior is also important. Decision-support tools that consider the role of a defender's experience and tolerance to threats along with the nature of adversarial behavior are likely to improve a defender's overall threat detection.
Abdollahnejad, Fatemeh; Mosaddegh, Mahmoud; Nasoohi, Sanaz; Mirnajafi-Zadeh, Javad; Kamalinejad, Mohammad; Faizi, Mehrdad
2016-01-01
In this study, we investigated the sedative and hypnotic effects of the aqueous extract of Aloe vera on rats. In order to evaluate the overall hypnotic effects of the Aloe vera extract, open field and loss of righting reflex tests were primarily used. The sedative and hypnotic effects of the extract were then confirmed by detection of remarkable raise in the total sleeping time through analysis of electroencephalographic (EEG) recordings of animals. Analysis of the EEG recordings showed that there is concomitant change in Rapid Eye Movement (REM) and None Rapid Eye Movement (NREM) sleep in parallel with the prolonged total sleeping time. Results of the current research show that the extract has sedative-hypnotic effects on both functional and electrical activities of the brain. PMID:27610170
Fu, Jinfeng; Wang, Min; Guo, Huimin; Tian, Yuan; Zhang, Zunjian; Song, Rui
2015-01-01
Rhizoma et Radix Polygoni Cuspidati (Huzhang in Chinese, HZ) is a traditional medicinal plant in China. Many of the components of HZ have been proved to be bioactive while it is difficult to conduct a comprehensive chemical profiling of HZ as a consequence of the absence of efficient separation system and sensitive detective means. We developed a simple and effective method for comprehensive characterization of constituents in HZ. To develop a simple and effective method to characterize the components in HZ and provide useful information for subsequent metabolic studies of HZ. The components in HZ aqueous extract were characterized by using high performance liquid chromatography with UV diode-array detector (HPLC-DAD) and ion trap/time-of-flight mass spectrometric detection (HPLC-IT/TOF). Stilbenes, anthraquinones, gallates and tannins, naphthalenes and some other compounds were identified and confirmed by diagnostic fragment ions with accurate mass measurements, characteristic fragmentation pathways and relevant published literatures. Among the 238 constituents detected in HZ, a total number of 74 constituents were identified unambiguously or tentatively, including 29 compounds reported for the first time in HZ. The identification and structure elucidation of these chemicals provided essential data for quality control and further in vivo metabolic studies of HZ. Key words: Polygonum cuspidatum, HPLC-DAD, HPLC-IT/TOF, qualitative analysis.
On the relationship between human search strategies, conspicuity, and search performance
NASA Astrophysics Data System (ADS)
Hogervorst, Maarten A.; Bijl, Piet; Toet, Alexander
2005-05-01
We determined the relationship between search performance with a limited field of view (FOV) and several scanning- and scene parameters in human observer experiments. The observers (38 trained army scouts) searched through a large search sector for a target (a camouflaged person) on a heath. From trial to trial the target appeared at a different location. With a joystick the observers scanned through a panoramic image (displayed on a PC-monitor) while the scan path was registered. Four conditions were run differing in sensor type (visual or thermal infrared) and window size (large or small). In conditions with a small window size the zoom option could be used. Detection performance was highly dependent on zoom factor and deteriorated when scan speed increased beyond a threshold value. Moreover, the distribution of scan speeds scales with the threshold speed. This indicates that the observers are aware of their limitations and choose a (near) optimal search strategy. We found no correlation between the fraction of detected targets and overall search time for the individual observers, indicating that both are independent measures of individual search performance. Search performance (fraction detected, total search time, time in view for detection) was found to be strongly related to target conspicuity. Moreover, we found the same relationship between search performance and conspicuity for visual and thermal targets. This indicates that search performance can be predicted directly by conspicuity regardless of the sensor type.
Ding, Tian; Suo, Yuanjie; Zhang, Zhaohuan; Liu, Donghong; Ye, Xingqian; Chen, Shiguo; Zhao, Yong
2017-01-01
This study firstly developed a multiplex real-time PCR (RT-PCR) technique combined with a pre-enrichment step to simultaneously detect Staphylococcus aureus ( S. aureus ), Listeria monocytogenes ( L. monocytogenes ) and Salmonella spp. in raw milk and the dairy farm environment (feces, soil, feed, water) in one reaction. Brain heart infusion (BHI) broth was selected for the enrichment step to increase the density of the target bacteria by using an incubation of 4 h before multiplex RT-PCR. The results showed that the detection limit of the multiplex real-time assay was approximately 10 2 CFU/mL for pure cultures and artificially contaminated milk without enrichment, while 12, 14, and 10 CFU/25 mL, respectively, for S. aureus, L. monocytogenes , and Salmonella spp. after pre-enrichment. The newly developed multiplex RT-PCR assay was applied to 46 dairy farm environmental samples and raw milk samples covering a wide variety of sample types. The results demonstrated that the multiplex RT-PCR assay coupled with the BHI enrichment broth was suitable for the simultaneous screening of S. aureus, L. monocytogenes , and Salmonella spp. in the pasture environment and in raw milk. The multiplex RT-PCR assay clearly and successfully shortened the total detection time and reduced labor compared to conventional culture-based methods for testing natural samples.
Detection of gastro-oesophageal reflux in the neonatal unit.
Rossor, Thomas; Lingam, Ingran; Douiri, Abdel; Bhat, Ravindra; Greenough, Anne
2018-03-13
To determine whether a pH probe or multichannel intraluminal impedance (MII) more frequently detected gastro-oesophageal reflux and test the hypothesis that acid reflux was associated with lower baseline impedance. A prospective study of infants in whom reflux was suspected and evaluated using combined pH and multichannel impedance. Studies were considered abnormal if the acid index was >10% or there were >79MII reflux events in 24 hours. The acid index was the percentage of total study time with a pH
Miyake, Yuichi; Tokumura, Masahiro; Wang, Qi; Amagai, Takashi; Horii, Yuichi
2017-11-01
Here, we examined the incineration of extruded polystyrene containing hexabromocyclododecane (HBCD) in a pilot-scale incinerator under various combustion temperatures (800-950°C) and flue gas residence times (2-8sec). Rates of HBCD decomposition ranged from 99.996% (800°C, 2sec) to 99.9999% (950°C, 8sec); the decomposition of HBCD, except during the initial stage of combustion (flue gas residence time<2sec), followed a pseudo-first-order kinetics model. An Arrhenius plot revealed that the activation energy and frequency factor of the decomposition of HBCD by combustion were 14.2kJ/mol and 1.69sec -1 , respectively. During combustion, 11 brominated polycyclic aromatic hydrocarbons (BrPAHs) were detected as unintentional by-products. Of the 11 BrPAHs detected, 2-bromoanthracene and 1-bromopyrene were detected at the highest concentrations. The mutagenic and carcinogenic BrPAHs 1,5-dibromoanthracene and 1-bromopyrene were most frequently detected in the flue gases analyzed. The total concentration of BrPAHs exponentially increased (range, 87.8-2,040,000ng/m 3 ) with increasing flue gas residence time. Results from a qualitative analysis using gas chromatography/high-resolution mass spectrometry suggest that bromofluorene and bromopyrene (or fluoranthene) congeners were also produced during the combustion. Copyright © 2017. Published by Elsevier B.V.
Sensitive detection of porcine DNA in processed animal proteins using a TaqMan real-time PCR assay.
Pegels, N; González, I; Fernández, S; García, T; Martín, R
2012-01-01
A TaqMan real-time PCR method was developed for specific detection of porcine-prohibited material in industrial feeds. The assay combines the use of a porcine-specific primer pair, which amplifies a 79 bp fragment of the mitochondrial (mt) 12 S rRNA gene, and a locked nucleic acid (LNA) TaqMan probe complementary to a target sequence lying between the porcine-specific primers. The nuclear 18 S rRNA gene system, yielding a 77 bp amplicon, was employed as a positive amplification control to monitor the total content of amplifiable DNA in the samples. The specificity of the porcine primers-probe system was verified against different animal and plant species, including mammals, birds and fish. The applicability of the real-time PCR protocol to detect the presence of porcine mt DNA in feeds was determined through the analysis of 190 industrial feeds (19 known reference and 171 blind samples) subjected to stringent processing treatments. The performance of the method allows qualitative and highly sensitive detection of short fragments from porcine DNA in all the industrial feeds declared to contain porcine material. Although the method has quantitative potential, the real quantitative capability of the assay is limited by the existing variability in terms of composition and processing conditions of the feeds, which affect the amount and quality of amplifiable DNA.
Ding, Tian; Suo, Yuanjie; Zhang, Zhaohuan; Liu, Donghong; Ye, Xingqian; Chen, Shiguo; Zhao, Yong
2017-01-01
This study firstly developed a multiplex real-time PCR (RT-PCR) technique combined with a pre-enrichment step to simultaneously detect Staphylococcus aureus (S. aureus), Listeria monocytogenes (L. monocytogenes) and Salmonella spp. in raw milk and the dairy farm environment (feces, soil, feed, water) in one reaction. Brain heart infusion (BHI) broth was selected for the enrichment step to increase the density of the target bacteria by using an incubation of 4 h before multiplex RT-PCR. The results showed that the detection limit of the multiplex real-time assay was approximately 102 CFU/mL for pure cultures and artificially contaminated milk without enrichment, while 12, 14, and 10 CFU/25 mL, respectively, for S. aureus, L. monocytogenes, and Salmonella spp. after pre-enrichment. The newly developed multiplex RT-PCR assay was applied to 46 dairy farm environmental samples and raw milk samples covering a wide variety of sample types. The results demonstrated that the multiplex RT-PCR assay coupled with the BHI enrichment broth was suitable for the simultaneous screening of S. aureus, L. monocytogenes, and Salmonella spp. in the pasture environment and in raw milk. The multiplex RT-PCR assay clearly and successfully shortened the total detection time and reduced labor compared to conventional culture-based methods for testing natural samples. PMID:28620364
Aichivirus in Children with Diarrhea in Northern Italy.
Bergallo, Massimiliano; Galliano, Ilaria; Montanari, Paola; Rassu, Marco; Daprà, Valentina
2017-01-01
Since its discovery, Aichivirus (AiV) A has been detected, with an incidence of 0.9-4.1%, primarily when studying outbreaks of diarrhea in children or young adults. In this paper, we report the first detection of AiV in Piedmont, Italy, in pediatric patients. A total of 159 fecal specimens (from 96 males and 63 females) previously screened for rotaviruses, adenoviruses, noroviruses, human parechoviruses, saliviruses, and sapoviruses were collected from infants and children with acute gastroenteritis. The most commonly detected virus was norovirus GII (33.80%), fol lowed by rotavirus (21.30%), astrovirus (18.87%), boca virus (13.92%), sapovirus (10.90%), parechovirus (8%), norovirus GI (6.70%), adenovirus (1%), and salivirus (0.52%). Real-time polymerase chain reaction detected AiV A in 1 (0.62%) case subjects. AiV A was detected in monoinfection only in January. Our results indicate that AiV may be associated with a limited number of diarrhea cases in pediatric patients. © 2018 S. Karger AG, Basel.
Traffic Congestion Detection System through Connected Vehicles and Big Data
Cárdenas-Benítez, Néstor; Aquino-Santos, Raúl; Magaña-Espinoza, Pedro; Aguilar-Velazco, José; Edwards-Block, Arthur; Medina Cass, Aldo
2016-01-01
This article discusses the simulation and evaluation of a traffic congestion detection system which combines inter-vehicular communications, fixed roadside infrastructure and infrastructure-to-infrastructure connectivity and big data. The system discussed in this article permits drivers to identify traffic congestion and change their routes accordingly, thus reducing the total emissions of CO2 and decreasing travel time. This system monitors, processes and stores large amounts of data, which can detect traffic congestion in a precise way by means of a series of algorithms that reduces localized vehicular emission by rerouting vehicles. To simulate and evaluate the proposed system, a big data cluster was developed based on Cassandra, which was used in tandem with the OMNeT++ discreet event network simulator, coupled with the SUMO (Simulation of Urban MObility) traffic simulator and the Veins vehicular network framework. The results validate the efficiency of the traffic detection system and its positive impact in detecting, reporting and rerouting traffic when traffic events occur. PMID:27136548
Traffic Congestion Detection System through Connected Vehicles and Big Data.
Cárdenas-Benítez, Néstor; Aquino-Santos, Raúl; Magaña-Espinoza, Pedro; Aguilar-Velazco, José; Edwards-Block, Arthur; Medina Cass, Aldo
2016-04-28
This article discusses the simulation and evaluation of a traffic congestion detection system which combines inter-vehicular communications, fixed roadside infrastructure and infrastructure-to-infrastructure connectivity and big data. The system discussed in this article permits drivers to identify traffic congestion and change their routes accordingly, thus reducing the total emissions of CO₂ and decreasing travel time. This system monitors, processes and stores large amounts of data, which can detect traffic congestion in a precise way by means of a series of algorithms that reduces localized vehicular emission by rerouting vehicles. To simulate and evaluate the proposed system, a big data cluster was developed based on Cassandra, which was used in tandem with the OMNeT++ discreet event network simulator, coupled with the SUMO (Simulation of Urban MObility) traffic simulator and the Veins vehicular network framework. The results validate the efficiency of the traffic detection system and its positive impact in detecting, reporting and rerouting traffic when traffic events occur.
Correlation of glucosinolate content to myrosinase activity in horseradish (Armoracia rusticana).
Li, Xian; Kushad, Mosbah M
2004-11-17
Fully developed horseradish (Armoracia rusticana Gaertn., Mey., & Scherb.) roots from 27 accessions and leaves from a subset of 9 accessions were evaluated for glucosinolates and myrosinase enzyme activity. Eight different glucosinolates were detected (based on HPLC retention times as desulfoglucosinolates) in both root and leaf tissues. The sum of these glucosinolates, referred to as total, ranged from 2 to 296 micromol g(-1) of dry weight (DW) in both tissues. Four glucosinolates (sinigrin, glucobrassicin, neoglucobrassicin, and gluconasturtiin) were detected in major quantities. In fully developed roots, sinigrin concentration represented approximately 83%, gluconasturtiin approximately 11%, and glucobrassicin approximately 1% of the total glucosinolates. Approximately the same proportions of individual glucosinolates appeared in fully developed leaves, except that glucobrassicin was substituted by neoglucobrassicin and gluconasturtiin concentration was significantly lower (<1%). At least four other glucosinolates were detected in very small quantities (<1%) in both roots and leaves. Myrosinase (beta-thioglucoside glucohydrolase, EC 3.2.3.1) is the enzyme responsible for the hydrolysis of the parent glucosinolates into biologically active products. Very little is known about myrosinase activity and the correlation of its activity to total and individual glucosinolates in plant tissues. Significant differences in myrosinase activity were detected between the roots and leaves, ranging from 1.2 to 57.1 units g(-1) of DW. Data showed no correlation between myrosinase activity and total and/or individual glucosinolates in the roots. However, in the leaves, significant correlations were found between myrosinase activity and total glucosinolates (0.78 at P = 0.01) and between myrosinase activity and sinigrin (0.80 at P = 0.01). Glucosinolates content and myrosinase activity were also correlated in young and fully developed roots and leaves and during tissue crushing. Glucobrassicin concentration in the roots and neoglucobrassicin concentration in the leaves were significantly higher in young than in fully developed tissue. Crushing of the tissue resulted in rapid hydrolysis of sinigrin and glucobrassicin, as expected, from the presence of myrosinase. Likewise, myrosinase activity declined rapidly after crushing, perhaps due to inactivation by the reaction products and/or the depletion of its substrates.
Phaneuf, D; DesGranges, J L; Plante, N; Rodrigue, J
1995-02-01
This study on wildlife contamination, one to ten months after the polychlorinated biphenyls (PCB) fire in St Basile le Grand, Quebec, shows that the fire increased PCB and polychlorinated dibenzofuran (PCDF) levels in animals. From the data, it was not possible to detect a significant increase in polychlorinated dibenzodioxin (PCDD) levels after the fire. Given the relatively small sample size, the differences in concentrations could not be estimated precisely. However, it can be asserted with a 95% confidence level that mean concentrations of total PCBs were roughly 2 to 6 times higher in the area contaminated by the plume of smoke, concentrations of homologues with 3 chlorine atoms were 1 to 4 times higher, and levels of homologues with 5 to 9 chlorine atoms were 3 to 13 times higher. The relative deviations between concentrations in areas under the plume and those outside it were similar for all animals sampled. With regard to total PCDFs, mean concentrations were significantly higher under the smoke plume than outside it for all species. This observation is linked to homologues with 4, 5 and 7 chlorine atoms for which significant differences were detected between the two areas. The fire had no effect on the pattern of PCB congeners found in the tissue of animals in the region. Congeners Nos. 153, 180, 138 and 118 represent approximately 50% of total PCBs. Although PCB and PCDF concentrations were higher in the tissue of local wildlife species exposed to the fire, they were nonetheless comparable to those found in other urban and agricultural areas in Canada. These concentrations, in 2,3,7,8-TCDD toxic equivalents, were much lower than those observed in the wake of three other major incidents involving PCDDs (Elgin, Florida; Times Beach, Missouri; and Seveso, Italy).(ABSTRACT TRUNCATED AT 250 WORDS)
Linearizing an intermodulation radar transmitter by filtering switched tones
NASA Astrophysics Data System (ADS)
Mazzaro, Gregory J.; Sherbondy, Andrew J.; Ranney, Kenneth I.; Sherbondy, Kelly D.; Martone, Anthony F.
2017-05-01
For nonlinear radar, the transmit power required to measure a detectable response from a target is relatively high, and generating that high power is achieved at the cost of linearity. This paper applies the distortion mitigation technique Linearization by Time-Multiplexed Spectrum (LITMUS) to intermodulation radar, a type of nonlinear radar which receives spectral content produced by the mixing of multiple frequencies at a nonlinear target. By implementing LITMUS, an experimental detection system for an intermodulation radar achieves a signal-to-noise ratio up to 20 dB for a total transmit power of approximately 80 mW and nonlinear targets placed at a standoff distance of 2 meters.
Camer, Gerry Amor; Alejandria, Marissa; Amor, Miguel; Satoh, Hiroshi; Muramatsu, Yasukazu; Ueno, Hiroshi; Morita, Chiharu
2003-02-01
A total of 157 sera from febrile patients in the Philippine General Hospital in Manila, Luzon, and the Northern Samar Provincial Hospital, the Philippines, were used. Serum antibodies against spotted fever group Rickettsia (SFGR) and typhus group Rickettsia (TGR) were detected by indirect immunofluorescence test. Antibody positive rates were 1.3% for SFGR (Rickettsia japonica) and 2.5% for TGR (R. typhus), respectively. Rickettsial antibodies in humans in the Philippines were found for the first time. These results underscore the need for further epidemiological study of clinical rickettsioses in the Philippines.
Temporal evolution of total ozone and circulation patterns over European mid-latitudes
NASA Astrophysics Data System (ADS)
Monge Sanz, B. M.; Casale, G. R.; Palmieri, S.; Siani, A. M.
2003-04-01
Linear correlation analysis and the running correlation technique are used to investigate the interannual and interdecadal variations of total ozone (TO) over several mid-latitude European locations. The study includes the longest series of ozone data, that of the Swiss station of Arosa. TO series have been related to time series of two circulation indices, the North Atlantic Oscillation Index (NAOI) and the Arctic Oscillation Index (AOI). The analysis has been performed with monthly data, and both series containing all the months of the year and winter (DJFM) series have been used. Special attention has been given to winter series, which exhibit very high correlation coefficients with NAOI and AOI; interannual variations of this relationship are studied by applying the running correlation technique. TO and circulation indices data series have been also partitioned into their different time-scale components with the Kolmogorov-Zurbenko method. Long-term components indicate the existence of strong opposite connection between total ozone and circulation patterns over the studied region during the last three decades. However, it is also observed that this relation has not always been so, and in previous times differences in the correlation amplitude and sign have been detected.
Finnegan, Dennis P.; Simonson, Laura A.; Meyer, Michael T.
2010-01-01
The occurrence of antibiotics in surface water and groundwater in urban basins has become a topic of increasing interest in recent years. Little is known about the occurrence, fate, or transport of these compounds and the possible health effects in humans and aquatic life. The U.S. Geological Survey, in cooperation with the City of Columbus, Division of Power and Water, did a study to provide a synoptic view of the occurrence of antibiotics in source and finished waters in the upper Scioto River Basin. Water samples were collected seasonally-winter (December 2005), spring (May 2006), summer (August 2006) and fall (October 2006)-at five surface-water sites, one groundwater site, and three water-treatment plants (WTPs). Within the upper Scioto River Basin, sampling at each WTP involved two sampling sites: a source-water intake site and a finished-water site. One or more antibiotics were detected at 11 of the 12 sampling sites. Of the 49 targeted antibiotic compounds, 12 (24 percent) were detected at least one time for a total of 61 detections overall. These compounds were azithromycin, tylosin, erythromycin-H2O, erythromycin, roxithromycin, ciprofloxacin, ofloxacin, sulfamethazine, sulfamethoxazole, iso-chlorotetracycline, lincomycin, and trimethoprim. Detection results were at low levels, with an overall median of 0.014 (u or mu)g/L. Hap Cremean WTP had the fewest detections, with two source-water detections of sulfamethoxazole and azithromycin and no detections in the finished water. Of the total of 61 detections, 31 were in the winter sample run. Sulfamethoxazale and azithromycin detections represent 41 percent of all antibiotic detections. Azithromycin was detected only in the winter sample. Some antibiotics, such as those in the quinoline and tetracycline families, dissipate more quickly in warm water, which may explain why they were detected in the cool months (winter, spring, and fall) and not in the summer. Antibiotic data collected during this study were compared to antibiotic data collected in previous national, regional, and local studies. Many of the same antibiotic compounds detected in the upper Scioto River Basin also were detected in those investigations.
Spectral-Based Volume Sensor Prototype, Post-VS4 Test Series Algorithm Development
2009-04-30
Computer Pcorr Probabilty / Percentage of Correct Classification (# Correct / # Total) PD PhotoDiode Pd Probabilty / Percentage of Detection (# Correct...Detections / Total of Sources) Pfa Probabilty / Percentage of False Alarm (# FAs / Total # of Sources) SBVS Spectral-Based Volume Sensor SFA Smoke and