Sample records for total dose commitments

  1. Population dose commitments due to radioactive releases from nuclear-power-plant sites in 1978

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peloquin, R.A.; Schwab, J.D.; Baker, D.A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1978. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each site. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each site is a histogram showing the fraction of the total population within 2 to 80 km around each site receiving variousmore » average dose commitments from the airborne pathways. The total dose commitment from both liquid and airborne pathways ranged from a high of 200 person-rem to a low of 0.0004 person-rem with an arithmetic mean of 14 person-rem. The total population dose for allsites was estimated at 660 person-rem for the 93 million people considered at risk. The average individual dose commitment from all pathways on a site basis ranged from a low of 3 x 10/sup -6/ mrem to a high of 0.08 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites.« less

  2. Population dose commitments due to radioactive releases from Nuclear-Power-Plant Sites in 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.; Peloquin, R.A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1979. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each site. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each site is a histogram showing the fraction of the total population within 2 to 80 km around each site receiving variousmore » average dose commitments from the airborne pathways. The total dose commitment from both liquid and airborne pathways ranged from a high of 1300 person-rem to a low of 0.0002 person-rem with an arithmetic mean of 38 person-rem. The total population dose for all sites was estimated at 1800 person-rem for the 94 million people considered at risk. The average individual dose commitment from all pathways on a site basis ranged from a low of 2 x 10/sup -6/ mrem to a high of 0.7 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites.« less

  3. Population Dose Commitments Due to Radioactive Releases from Nuclear Power Plant Sites in 1977

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D. A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1977. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each site. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ, Also included for each site is a histogram showing the fraction of the total population within 2 to 80 km around each site receiving variousmore » average dose commitments from the airborne pathways. The total dose commitment from both liquid and airborne pathways ranged from a high of 220 person-rem to a low of 0.003 person-rem with an arithmetic mean of 16 person-rem. The total population dose for all sites was estimated at 700 person-rem for the 92 million people considered at risk. The average individual dose commitment from all pathways on a site basis ranged from a low of 2 x 10{sup -5} mrem to a high of 0.1 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites.« less

  4. Population dose commitments due to radioactive releases from nuclear power plant sites in 1980

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.; Peloquin, R.A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1980. In addition doses derived from the shutdown reactors at the Three Mile Island site were included. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each site. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each site is a histogram showingmore » the fraction of the total population within 2 to 80 km around each site receiving various average dose commitments from the airborne pathways. The total dose commitment from both liquid and airborne pathways ranged from a high of 40 person-rem to a low of 0.02 person-rem with an arithmetic mean of 4 person-rem. The total population dose for all sites was estimated at 180 person-rem for the 96 million people considered at risk.« less

  5. Population dose commitments due to radioactive releases from nuclear power plant sites in 1985

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commericial power reactors operating during 1985. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 61 sites. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each of the sites is a histogram showing the fraction of the total population within 2 to 80 km aroundmore » each site receiving various average dose commitments from the airborne pathways. The total dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 73 person-rem to a low of 0.011 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 3 person-rem. The total population dose for all sites was estimated at 200 person-rem for the 110 million people considered at risk. The site average individual dose commitment from all pathways ranged from a low of 5 /times/ 10/sup /minus/6/ mrem to a high of 0.02 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites.« less

  6. Population dose commitments due to radioactive releases from nuclear power plant sites in 1984

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1984. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 56 sites. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each of the sites is a histogram showing the fraction of the total population within 2 to 80 km aroundmore » each site receiving various average dose commitments from the airborne pathways. The total dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 110 person-rem to a low of 0.002 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 5 person-rem. The total population dose for all sites was estimated at 280 person-rem for the 100 million people considered at risk. The site average individual dose commitment from all pathways ranged from a low of 6 x 10/sup -6/ mrem to a high of 0.04 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites.« less

  7. Population dose commitments due to radioactive releases from nuclear power plant sites in 1986

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1986. Fifty-year dose commitments for a one-year exposure from both liquid and atmospheric releases were calculated for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 66 reactor sites. This report tabulates the results of these calculations, showing the dose commitments for both water and airborne pathways for each age group and organ. Also included for each of the sites is a histogram showing the fraction of the total population within 2 to 80 kmmore » around each site receiving various average dose commitments from the airborne pathways. The total dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 31 person-rem to a low of 0.0007 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 1.7 person-rem. The total population dose for all sites was estimated at 110 person-rem for the 140 million people considered at risk. The site average individual dose commitment from all pathways ranged from a low of 2 {times} 10{sup -6} mrem to a high of 0.02 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites. 12 refs.« less

  8. Population dose commitments due to radioactive releases from nuclear power plant sites in 1982. Volume 4

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.; Peloquin, R.A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1982. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 51 sites. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each site is a histogram showing the fraction of the total population within 2 to 80 km around each sitemore » receiving various average dose commitments from the airborne pathways. The total dose commitments from both liquid and airborne pathways ranged from a high of 30 person-rem to a low of 0.007 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 3 person-rem. The total population dose for all sites was estimated at 130 person-rem for the 100 million people considered at risk. The average individual dose commitment from all pathways on a site basis ranged from a low of 6 x 10/sup -7/ mrem to a high of 0.06 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites.« less

  9. Population dose commitments due to radioactive releases from nuclear power plant sites in 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.; Peloquin, R.A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1983. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 52 sites. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each of the sites is a histogram showing the fraction of the total population within 2 to 80 km aroundmore » each site receiving various average dose commitments from the airborne pathways. The total dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 45 person-rem to a low of 0.002 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 3 person-rem. The total population dose for all sites was estimated at 170 person-rem for the 100 million people considered at risk.« less

  10. Population dose commitments due to radioactive releases from nuclear power plant sites in 1988

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1988. Fifty-year commitments for a one-year exposure from both liquid and atmospheric releases were calculated for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 71 reactor sites. This report tabulates the results of these calculations, showing the dose commitments for both water and airborne pathways for each age group and organ. Also included for each of the sites is a histogram showing the fraction of the total population within 2 to 80 km aroundmore » each site receiving various average dose commitments from the airborne pathways. The total collective dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 16 person-rem to a low of 0.0011 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 1.1 person-rem. The total population dose for all sites was estimated at 75 person-rem for the 150 million people considered at risk. The site average individual dose commitment from all pathways ranged from a low of 3 {times} 10{sup {minus}7} mrem to a high of 0.02 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites. However, licensee calculation of doses to the maximally exposed individual at some sites indicated values of up to approximately 100 times average individual doses (on the order of a few millirem per year).« less

  11. Population dose commitments due to radioactive releases from nuclear power plant sites in 1988. Volume 10

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1988. Fifty-year commitments for a one-year exposure from both liquid and atmospheric releases were calculated for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 71 reactor sites. This report tabulates the results of these calculations, showing the dose commitments for both water and airborne pathways for each age group and organ. Also included for each of the sites is a histogram showing the fraction of the total population within 2 to 80 km aroundmore » each site receiving various average dose commitments from the airborne pathways. The total collective dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 16 person-rem to a low of 0.0011 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 1.1 person-rem. The total population dose for all sites was estimated at 75 person-rem for the 150 million people considered at risk. The site average individual dose commitment from all pathways ranged from a low of 3 {times} 10{sup {minus}7} mrem to a high of 0.02 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites. However, licensee calculation of doses to the maximally exposed individual at some sites indicated values of up to approximately 100 times average individual doses (on the order of a few millirem per year).« less

  12. Dose commitments due to radioactive releases from nuclear power plant sites in 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.

    Population and individual radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1989. Fifty-year dose commitments for a one-year exposure from both liquid and atmospheric releases were calculated for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 72 reactor sites. This report tabulates the results of these calculations, showing the dose commitments for both water and airborne pathways for each age group and organ. Also included for each of the sites is an estimate of individual doses which are compared with 10 CFR Partmore » 50, Appendix I design objectives. The total collective dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 14 person-rem to a low of 0.005 person-rem for the sites with plants in operation and producing power during the year. The arithmetic mean was 1.2 person-rem. The total population dose for all sites was estimated at 84 person-rem for the 140 million people considered at risk. The individual dose commitments estimated for all sites were below the Appendix I design objectives.« less

  13. Dose commitments due to radioactive releases from nuclear power plant sites in 1989. Volume 11

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.

    Population and individual radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1989. Fifty-year dose commitments for a one-year exposure from both liquid and atmospheric releases were calculated for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 72 reactor sites. This report tabulates the results of these calculations, showing the dose commitments for both water and airborne pathways for each age group and organ. Also included for each of the sites is an estimate of individual doses which are compared with 10 CFR Partmore » 50, Appendix I design objectives. The total collective dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 14 person-rem to a low of 0.005 person-rem for the sites with plants in operation and producing power during the year. The arithmetic mean was 1.2 person-rem. The total population dose for all sites was estimated at 84 person-rem for the 140 million people considered at risk. The individual dose commitments estimated for all sites were below the Appendix I design objectives.« less

  14. Assessment of radiation doses from residential smoke detectors that contain americium-241

    NASA Astrophysics Data System (ADS)

    Odonnell, F. R.; Etnier, E. L.; Holton, G. A.; Travis, C. C.

    1981-10-01

    External dose equivalents and internal dose commitments were estimated for individuals and populations from annual distribution, use, and disposal of 10 million ionization chamber smoke detectors that contain 110 kBq americium-241 each. Under exposure scenarios developed for normal distribution, use, and disposal using the best available information, annual external dose equivalents to average individuals were estimated to range from 4 fSv to 20 nSv for total body and from 7 fSv to 40 nSv for bone. Internal dose commitments to individuals under post disposal scenarios were estimated to range from 0.006 to 80 micro-Sv (0.0006 to 8 mrem) to total body and from 0.06 to 800 micro-Sv to bone. The total collective dose (the sum of external dose equivalents and 50-year internal dose commitments) for all individuals involved with distribution, use, or disposal of 10 million smoke detectors was estimated to be about 0.38 person-Sv (38 person-rem) to total body and 00 ft squared.

  15. Assessment of radiation doses from residential smoke detectors that contain americium-241

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Donnell, F.R.; Etnier, E.L.; Holton, G.A.

    1981-10-01

    External dose equivalents and internal dose commitments were estimated for individuals and populations from annual distribution, use, and disposal of 10 million ionization chamber smoke detectors that contain 110 kBq (3 ..mu..Ci) americium-241 each. Under exposure scenarios developed for normal distribution, use, and disposal using the best available information, annual external dose equivalents to average individuals were estimated to range from 4 fSv (0.4 prem) to 20 nSv (2 ..mu..rem) for total body and from 7 fSv to 40 nSv for bone. Internal dose commitments to individuals under post disposal scenarios were estimated to range from 0.006 to 80 ..mu..Svmore » (0.0006 to 8 mrem) to total body and from 0.06 to 800 ..mu..Sv to bone. The total collective dose (the sum of external dose equivalents and 50-year internal dose commitments) for all individuals involved with distribution, use, or disposal of 10 million smoke detectors was estimated to be about 0.38 person-Sv (38 person-rem) to total body and 00 ft/sup 2/).« less

  16. Dosimetric assessment from 212Pb inhalation at a thorium purification plant.

    PubMed

    Campos, M P; Pecequilo, B R S

    2004-01-01

    At the Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, Brazil, there is a facility (thorium purification plant) where materials with high thorium concentrations are manipulated. In order to estimate afterwards the lung cancer risk for the workers, the thoron daughter (212Pb) levels were assessed and the committed effective and lung committed equivalent doses for workers in place. A total of 28 air filter samples were measured by total alpha counting through the modified Kusnetz method, to determine the 212Pb concentraion. The committed effective dose and lung committed equivalent dose due to 212Pb inhalation were derived from compartmental analysis following the ICRP 66 lung compartmental model, and ICRP 67 lead metabolic model.

  17. Annual committed effective dose from olive oil (due to 238U, 232Th, and 222Rn) estimated for members of the Moroccan public from ingestion and skin application.

    PubMed

    Misdaq, M A; Touti, R

    2012-03-01

    Olive oil is traditionally refined and widely consumed by Moroccan rural populations. Uranium (238U), thorium (232Th), radon (222Rn), and thoron (220Rn) contents were measured in various locally produced olive oil samples collected in rural areas of Morocco. These radionuclides were also measured inside various bottled virgin olive oils consumed by the Moroccan populations. CR-39 and LR-115 type II solid state nuclear track detectors (SSNTDs) were used. Annual committed effective doses due to 238U, 232Th, and 222Rn from the ingestion of olive oil by the members of the general public were determined. The maximum total committed effective dose due to 238U, 232Th, and 222Rn from the ingestion of olive oil by adult members of Moroccan rural populations was found equal to 5.9 µSv y-1. The influence of pollution due to building material dusts and phosphates on the radiation dose to workers from the ingestion of olive oil was investigated, and it was found that the maximum total committed effective dose due to 238U, 232Th, and 222Rn was on the order of 0.22 mSy y-1. Committed effective doses to skin due to 238U, 232Th, and 222Rn from the application of olive oil masks by rural women were evaluated. The maximum total committed effective dose to skin due to 238U, 232Th, and 222Rn was found equal to 0.07 mSy y-1 cm-2.

  18. 40 CFR Appendix B to Part 191 - Calculation of Annual Committed Effective Dose

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the proportion of the stochastic risk resulting from irradiation of the tissue or organ to the total... of HE. III. Annual Committed Tissue or Organ Equivalent Dose For internal irradiation from...

  19. 40 CFR Appendix B to Part 191 - Calculation of Annual Committed Effective Dose

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the proportion of the stochastic risk resulting from irradiation of the tissue or organ to the total... of HE. III. Annual Committed Tissue or Organ Equivalent Dose For internal irradiation from...

  20. 40 CFR Appendix B to Part 191 - Calculation of Annual Committed Effective Dose

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the proportion of the stochastic risk resulting from irradiation of the tissue or organ to the total... of HE. III. Annual Committed Tissue or Organ Equivalent Dose For internal irradiation from...

  1. 40 CFR Appendix B to Part 191 - Calculation of Annual Committed Effective Dose

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the proportion of the stochastic risk resulting from irradiation of the tissue or organ to the total... of HE. III. Annual Committed Tissue or Organ Equivalent Dose For internal irradiation from...

  2. 40 CFR Appendix B to Part 191 - Calculation of Annual Committed Effective Dose

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the proportion of the stochastic risk resulting from irradiation of the tissue or organ to the total... of HE. III. Annual Committed Tissue or Organ Equivalent Dose For internal irradiation from...

  3. Population dose commitments due to radioactive releases from nuclear power plant sites in 1987

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1987. Fifty-year dose commitments for a one-year exposure from both liquid and atmospheric releases were calculated for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 70 reactor sites. This report tabulates the results of these calculations, showing the dose commitments for both water and airborne pathways for each age group and organ. Also included for reach of the sites is a histogram showing the fraction of the total population within 2 to 80 kmmore » around each site receiving various average dose commitments from the airborne pathways. The site average individual dose commitment from all pathways ranged from a low of 2 {times} 10{sup {minus}6} mrem to a high of 0.009 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites. However, licensee calculation of doses to the maximally exposed individual at some sites indicated values of up to approximately 100 times average individual doses (on the order of a few millirem per year). 2 refs., 2 figs., 7 tabs.« less

  4. 40 CFR Appendix A to Part 197 - Calculation of Annual Committed Effective Dose Equivalent

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... resulting from irradiation of the tissue or organ to the total risk when the whole body is irradiated... internal irradiation from incorporated radionuclides, the total absorbed dose will be spread out in time...

  5. 40 CFR Appendix A to Part 197 - Calculation of Annual Committed Effective Dose Equivalent

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... resulting from irradiation of the tissue or organ to the total risk when the whole body is irradiated... internal irradiation from incorporated radionuclides, the total absorbed dose will be spread out in time...

  6. 40 CFR Appendix A to Part 197 - Calculation of Annual Committed Effective Dose Equivalent

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... resulting from irradiation of the tissue or organ to the total risk when the whole body is irradiated... internal irradiation from incorporated radionuclides, the total absorbed dose will be spread out in time...

  7. 40 CFR Appendix A to Part 197 - Calculation of Annual Committed Effective Dose Equivalent

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... resulting from irradiation of the tissue or organ to the total risk when the whole body is irradiated... internal irradiation from incorporated radionuclides, the total absorbed dose will be spread out in time...

  8. 40 CFR Appendix A to Part 197 - Calculation of Annual Committed Effective Dose Equivalent

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... resulting from irradiation of the tissue or organ to the total risk when the whole body is irradiated... internal irradiation from incorporated radionuclides, the total absorbed dose will be spread out in time...

  9. Age-specific radiation dose commitment factors for a one-year chronic intake

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoenes, G.R.; Soldat, J.K.

    1977-11-01

    During the licensing process for nuclear facilities, radiation doses and dose commitments must be calculated for people in the environs of a nuclear facility. These radiation doses are determined by examining characteristics of population groups, pathways to people, and radionuclides found in those pathways. The pertinent characteristics, which are important in the sense of contributing a significant portion of the total dose, must then be analyzed in depth. Dose factors are generally available for adults, see Reference 1 for example, however numerous improvements in data on decay schemes and half-lives have been made in recent years. In addition, it ismore » advisable to define parameters for calculation of the radiation dose for ages other than adults since the population surrounding nuclear facilities will be composed of various age groups. Further, since infants, children, and teens may have higher rates of intake per unit body mass, it is conceivable that the maximally exposed individual may not be an adult. Thus, it was necessary to develop new radiation-dose commitment factors for various age groups. Dose commitment factors presented in this report have been calculated for a 50-year time period for four age groups.« less

  10. Evaluation of annual committed effective doses to members of the public in Morocco due to 238U and 232Th in various food materials.

    PubMed

    Misdaq, M A; Bourzik, W

    2004-12-01

    Uranium (238U) and thorium (232Th) concentrations were measured in different foods widely consumed in Morocco by using CR-39 and LR-115 type II solid state nuclear track detectors (SSNTDs). Annual committed effective doses due to 238U and 232Th intakes from the ingestion of the studied food materials were evaluated for different age groups of individuals, using the ICRP ingestion dose coefficients. The influence of the 238U and 232Th intakes and ages of individuals on the committed effective dose was investigated. Total annual intakes of 238U and 232Th for a typical food basket for adult members of the Moroccan population were estimated to be 451 +/- 27 Bq y(-1) and 359 +/- 20 Bq y(-1), corresponding to committed effective doses of (20 +/- 1) x 10(-6) Sv y(-1) and (83 +/- 5) x 10(-6) Sv y(-1), respectively.

  11. Age-specific inhalation radiation dose commitment factors for selected radionuclides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strenge, D.L.; Peloquin, R.A.; Baker, D.A.

    Inhalation dose commitment factors are presented for selected radionuclides for exposure of individuals in four age groups: infant, child, teen and adult. Radionuclides considered are /sup 35/S, /sup 36/Cl, /sup 45/Ca, /sup 67/Ga, /sup 75/Se, /sup 85/Sr, /sup 109/Cd, /sup 113/Sn, /sup 125/I, /sup 133/Ba, /sup 170/Tm, /sup 169/Yb, /sup 182/Ta, /sup 192/Ir, /sup 198/Au, /sup 201/Tl, /sup 204/Tl, and /sup 236/Pu. The calculational method is based on the human metabolic model of ICRP as defined in Publication 2 (ICRP 1959) and as used in previous age-specific dose factor calculations by Hoenes and Soldat (1977). Dose commitment factors are presentedmore » for the following organs of reference: total body, bone, liver, kidney, thyroid, lung and lower large intestine.« less

  12. 10 CFR 60.136 - Preclosure controlled area.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The eye dose equivalent shall not exceed 0.15 Sv (15 rem), and the shallow dose...

  13. 10 CFR 60.136 - Preclosure controlled area.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The eye dose equivalent shall not exceed 0.15 Sv (15 rem), and the shallow dose...

  14. 10 CFR 60.136 - Preclosure controlled area.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The eye dose equivalent shall not exceed 0.15 Sv (15 rem), and the shallow dose...

  15. 10 CFR 60.136 - Preclosure controlled area.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The eye dose equivalent shall not exceed 0.15 Sv (15 rem), and the shallow dose...

  16. 10 CFR 60.136 - Preclosure controlled area.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The eye dose equivalent shall not exceed 0.15 Sv (15 rem), and the shallow dose...

  17. 210Po in the diet at Seville (Spain) and its contribution to the dose by ingestion

    PubMed Central

    Díaz-Francés, I.; Mantero, J.; Díaz-Ruiz, J.; Manjón, G.; García-Tenorio, R.

    2016-01-01

    The activity concentrations of 210Po have been determined in a total of 24 representative diet samples from Seville (south of Spain), inferring from the obtained values the annual intakes of 210Po by ingestion of the affected population and the corresponding committed effective doses. The annual intakes of 210Po and, consequently, the corresponding doses of this radionuclide show a high variability in correspondence with the variability in the composition of the analysed samples over time, and their magnitude is comparable with the estimated ones in other regions/countries of the world with similar diet habits (countries where the marine products have a considerable weight in the diets). Committed effective doses by ingestion higher than 0.1 mSv y−1 have been estimated exclusively for 210Po, reflecting the importance of this radionuclide and this route of incorporation in the magnitude of the total doses received by the affected population from natural sources. PMID:25802464

  18. 10 CFR 72.106 - Controlled area of an ISFSI or MRS.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... controlled area may not receive from any design basis accident the more limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose...

  19. 10 CFR 72.106 - Controlled area of an ISFSI or MRS.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... controlled area may not receive from any design basis accident the more limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose...

  20. 10 CFR 72.106 - Controlled area of an ISFSI or MRS.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... controlled area may not receive from any design basis accident the more limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose...

  1. 10 CFR 72.106 - Controlled area of an ISFSI or MRS.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... controlled area may not receive from any design basis accident the more limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose...

  2. 10 CFR 72.106 - Controlled area of an ISFSI or MRS.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... controlled area may not receive from any design basis accident the more limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose...

  3. Internal exposure to (210)Po and (40)K from ingestion of cooked daily foodstuffs for adults in Japanese cities.

    PubMed

    Sugiyama, Hideo; Terada, Hiroshi; Isomura, Kimio; Iijima, Ikuyo; Kobayashi, Jun; Kitamura, Kiyoshi

    2009-10-01

    The isotope (210)Po was suspected of being involved in the death of a former Russian intelligence agent in 2006 in the UK. Although human exposure to this natural radionuclide in foods is estimated to be high, few studies are available. UNSCEAR Report 2000 does not contain data on (210)Po concentrations of foodstuffs in Japan. We analyzed samples of the everyday Japanese diet cooked with foodstuffs purchased at supermarkets in 7 major domestic cities in 2007-2008. (210)Po was quantified by alpha spectrometry and natural radionuclides such as (40)K by gamma spectrometry. The daily intake and committed effective dose of (210)Po, (40)K, and other natural radionuclides for Japanese adults were calculated. Daily intake was 0.34-1.84 (mean +/- sigma : 0.66 +/- 0.53) and 68.5-94.2 (81.5 +/- 8.5) Bq/d and the committed effective dose was 0.15-0.81 (0.29 +/- 0.24) and 0.16-0.21 (0.18 +/- 0.02) mSv for (210)Po and (40)K, respectively, comprising a high percentage of the total exposure. The total of the mean committed effective dose for the two nuclides (0.47 mSv) was higher than the annual effective dose from ingestion of foods reported by UNSCEAR 2000 (0.29 mSv). The mean committed effective dose of (40)K in the 7 major Japanese cities was comparable to the global average (0.17 mSv). The dietary exposure of Japanese adults can be characterized by a higher (210)Po contribution than in other countries. Of the total daily dietary (210)Po exposure (13 food categories excluding water) for adults in Yokohama, about 70% was from fish/shellfish and 20% from vegetables/mushrooms/seaweeds, reflecting preferences of Japanese to eat a considerable amount of fish/shellfish containing high (210)Po concentrations.

  4. ²¹⁰Po in the diet at Seville (Spain) and its contribution to the dose by ingestion.

    PubMed

    Díaz-Francés, I; Mantero, J; Díaz-Ruiz, J; Manjón, G; García-Tenorio, R

    2016-02-01

    The activity concentrations of (210)Po have been determined in a total of 24 representative diet samples from Seville (south of Spain), inferring from the obtained values the annual intakes of (210)Po by ingestion of the affected population and the corresponding committed effective doses. The annual intakes of (210)Po and, consequently, the corresponding doses of this radionuclide show a high variability in correspondence with the variability in the composition of the analysed samples over time, and their magnitude is comparable with the estimated ones in other regions/countries of the world with similar diet habits (countries where the marine products have a considerable weight in the diets). Committed effective doses by ingestion higher than 0.1 mSv y(-1) have been estimated exclusively for (210)Po, reflecting the importance of this radionuclide and this route of incorporation in the magnitude of the total doses received by the affected population from natural sources. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. [Estimation of dietary intake of radioactive materials by total diet methods].

    PubMed

    Uekusa, Yoshinori; Nabeshi, Hiromi; Tsutsumi, Tomoaki; Hachisuka, Akiko; Matsuda, Rieko; Teshima, Reiko

    2014-01-01

    Radioactive contamination in foods is a matter of great concern after the Tokyo Electric Power Company's Fukushima Daiichi nuclear power plant disaster caused by the Great East Japan Earthquake. In order to estimate human intake and annual committed effective dose of radioactive materials, market basket and duplicate diet samples from various areas in Japan were analyzed for cesium-134 ((134)Cs), -137 ((137)Cs), and natural radionuclide potassium-40 ((40)K) by γ-ray spectroscopy. Dietary intake of radioactive cesium around Fukushima area was somewhat higher than in other areas. However, maximum committed effective doses obtained by the market basket and duplicate diet samples were 0.0094 and 0.027 mSv/year, respectively, which are much lower than the maximum permissible dose (1 mSv/year) in foods in Japan.

  6. Fukushima radionuclides in the NW Pacific, and assessment of doses for Japanese and world population from ingestion of seafood

    PubMed Central

    Povinec, Pavel P.; Hirose, Katsumi

    2015-01-01

    Variations of Fukushima-derived radionuclides (90Sr, 134Cs and 137Cs) in seawater and biota offshore Fukushima and in the NW Pacific Ocean were investigated and radiation doses to the Japanese and world population from ingestion of seafood contaminated by Fukushima radionuclides were estimated and compared with those from other sources of anthropogenic and natural radionuclides. The total effective dose commitment from ingestion of radionuclides in fish, shellfish and seaweed caught in coastal waters off Fukushima was estimated to be 0.6 ± 0.4 mSv/y. The individual effective dose commitment from consumption of radioactive-contaminated fish caught in the open Pacific Ocean was estimated to be 0.07 ± 0.05 mSv/y. These doses are comparable or much lower than doses delivered from the consumption of natural 210Po in fish and in shellfish (0.7 mSv/y). The estimated individual doses have been below the levels when any health damage of the Japanese and world population could be expected. PMID:25761420

  7. Fukushima radionuclides in the NW Pacific, and assessment of doses for Japanese and world population from ingestion of seafood.

    PubMed

    Povinec, Pavel P; Hirose, Katsumi

    2015-03-12

    Variations of Fukushima-derived radionuclides ((90)Sr, (134)Cs and (137)Cs) in seawater and biota offshore Fukushima and in the NW Pacific Ocean were investigated and radiation doses to the Japanese and world population from ingestion of seafood contaminated by Fukushima radionuclides were estimated and compared with those from other sources of anthropogenic and natural radionuclides. The total effective dose commitment from ingestion of radionuclides in fish, shellfish and seaweed caught in coastal waters off Fukushima was estimated to be 0.6 ± 0.4 mSv/y. The individual effective dose commitment from consumption of radioactive-contaminated fish caught in the open Pacific Ocean was estimated to be 0.07 ± 0.05 mSv/y. These doses are comparable or much lower than doses delivered from the consumption of natural (210)Po in fish and in shellfish (0.7 mSv/y). The estimated individual doses have been below the levels when any health damage of the Japanese and world population could be expected.

  8. 210Po and 238U isotope concentrations in commercial bottled mineral water samples in Spain and their dose contribution.

    PubMed

    Díaz-Francés, I; Mantero, J; Manjón, G; Díaz, J; García-Tenorio, R

    2013-09-01

    (210)Po is a naturally occurring radionuclide, belonging to the uranium series, which is present in minute amounts in the different environmental compartments (water, soil, biota). Through its route along the trophic chain, it can be incorporated in the human body via ingestion of waters and/or food. This radionuclide is highly radiotoxic, being one of the main contributors to the committed effective dose via ingestion by the general population. In this work, the contribution of this radionuclide to the committed effective dose received by the Spanish population via consumption of bottled mineral waters is evaluated. With this end, the (210)Po activity concentrations in a total of 32 different commercial bottled mineral waters have been determined by alpha-particle spectrometry. The determined contribution is also compared with the contributions of other natural radionuclides such as (234)U and (238)U.

  9. 10 CFR 835.702 - Individual monitoring records.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... emergency exposures. (b) Recording of the non-uniform equivalent dose to the skin is not required if the... internal dose (committed effective dose or committed equivalent dose) is not required for any monitoring...: (i) The effective dose from external sources of radiation (equivalent dose to the whole body may be...

  10. 10 CFR 835.702 - Individual monitoring records.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... emergency exposures. (b) Recording of the non-uniform equivalent dose to the skin is not required if the... internal dose (committed effective dose or committed equivalent dose) is not required for any monitoring...: (i) The effective dose from external sources of radiation (equivalent dose to the whole body may be...

  11. 10 CFR 835.702 - Individual monitoring records.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... emergency exposures. (b) Recording of the non-uniform equivalent dose to the skin is not required if the... internal dose (committed effective dose or committed equivalent dose) is not required for any monitoring...: (i) The effective dose from external sources of radiation (equivalent dose to the whole body may be...

  12. 10 CFR 835.702 - Individual monitoring records.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... emergency exposures. (b) Recording of the non-uniform equivalent dose to the skin is not required if the... internal dose (committed effective dose or committed equivalent dose) is not required for any monitoring...: (i) The effective dose from external sources of radiation (equivalent dose to the whole body may be...

  13. 10 CFR 835.702 - Individual monitoring records.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... emergency exposures. (b) Recording of the non-uniform equivalent dose to the skin is not required if the... internal dose (committed effective dose or committed equivalent dose) is not required for any monitoring...: (i) The effective dose from external sources of radiation (equivalent dose to the whole body may be...

  14. Dose commitments due to radioactive releases from nuclear power plant sites: Methodology and data base. Supplement 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.

    1996-06-01

    This manual describes a dose assessment system used to estimate the population or collective dose commitments received via both airborne and waterborne pathways by persons living within a 2- to 80-kilometer region of a commercial operating power reactor for a specific year of effluent releases. Computer programs, data files, and utility routines are included which can be used in conjunction with an IBM or compatible personal computer to produce the required dose commitments and their statistical distributions. In addition, maximum individual airborne and waterborne dose commitments are estimated and compared to 10 CFR Part 50, Appendix 1, design objectives. Thismore » supplement is the last report in the NUREG/CR-2850 series.« less

  15. 10 CFR Appendix B to Part 20 - Annual Limits on Intake (ALIs) and Derived Air Concentrations (DACs) of Radionuclides for...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) a committed effective dose equivalent of 5 rems (stochastic ALI) or (2) a committed dose equivalent of 50 rems to an organ or tissue (non-stochastic ALI). The stochastic ALIs were derived to result in... equivalent to the whole body of 5 rems. The derivation includes multiplying the committed dose equivalent to...

  16. 10 CFR Appendix B to Part 20 - Annual Limits on Intake (ALIs) and Derived Air Concentrations (DACs) of Radionuclides for...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) a committed effective dose equivalent of 5 rems (stochastic ALI) or (2) a committed dose equivalent of 50 rems to an organ or tissue (non-stochastic ALI). The stochastic ALIs were derived to result in... equivalent to the whole body of 5 rems. The derivation includes multiplying the committed dose equivalent to...

  17. 10 CFR Appendix B to Part 20 - Annual Limits on Intake (ALIs) and Derived Air Concentrations (DACs) of Radionuclides for...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) a committed effective dose equivalent of 5 rems (stochastic ALI) or (2) a committed dose equivalent of 50 rems to an organ or tissue (non-stochastic ALI). The stochastic ALIs were derived to result in... equivalent to the whole body of 5 rems. The derivation includes multiplying the committed dose equivalent to...

  18. 10 CFR Appendix B to Part 20 - Annual Limits on Intake (ALIs) and Derived Air Concentrations (DACs) of Radionuclides for...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) a committed effective dose equivalent of 5 rems (stochastic ALI) or (2) a committed dose equivalent of 50 rems to an organ or tissue (non-stochastic ALI). The stochastic ALIs were derived to result in... equivalent to the whole body of 5 rems. The derivation includes multiplying the committed dose equivalent to...

  19. 10 CFR Appendix B to Part 20 - Annual Limits on Intake (ALIs) and Derived Air Concentrations (DACs) of Radionuclides for...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...) a committed effective dose equivalent of 5 rems (stochastic ALI) or (2) a committed dose equivalent of 50 rems to an organ or tissue (non-stochastic ALI). The stochastic ALIs were derived to result in... equivalent to the whole body of 5 rems. The derivation includes multiplying the committed dose equivalent to...

  20. Assessment of Committed Effective Dose due to consumption of Red Sea coral reef fishes collected from the local market (Sudan).

    PubMed

    Hassona, Rifaat K; Sam, A K; Osman, O I; Sirelkhatim, D A; LaRosa, J

    2008-04-15

    An assessment of Committed Effective Dose (CED) due to consumption of Red Sea fish containing (210)Po and (137)Cs was performed for 23 different marine fish samples collected from the local market at Port Sudan. The fish were classified according to their feeding habits into three categories: carnivores, herbivores, and omnivores. Measured activity concentrations of (210)Po were found in the ranges 0.25-6.42 (carnivores), 0.7-5 (omnivores) and 1.5-3.8 (herbivores) Bq/kg fresh weight. In the same study, activity concentrations of Cs-137 were determined to be in the ranges 0.1-0.46 (carnivores), 0.09-0.35 (omnivores) and 0.09-0.32 (herbivores) Bq/kg fresh weight, which were several times lower than those of (210)Po. Appropriate conversion factors were used to derive the CED, which was found to be 0.012, 0.01 and 0.01 (microSv/yr) in carnivores, omnivores and herbivores, respectively, for (137)Cs. This contributes about 0.4% of the total dose exclusively by ingestion of fish. For (210)Po, it was found to be 3.47, 4.81 and 4.14 (microSv/yr) in carnivores, omnivores and herbivores, respectively, which represents 99.6% of the total dose (exclusively by ingestion of fish). The results of CED calculations suggest that the dose received by the Sudanese population from the consumption of marine fish is rather small and that the contribution of (137)Cs is negligible compared to (210)Po.

  1. Gross alpha and beta activity and annual committed effective dose due to natural radionuclides in some water spinach (ipomoea aquatica Forssk) samples in Ho Chi Minh City, Vietnam.

    PubMed

    Le, Hao Cong; Nguyen, Thang Van; Huynh, Thu Nguyen Phong; Huynh, Phuong Truc

    2017-07-01

    The results of gross alpha and beta radioactivity measurement in water spinach samples from some districts in Ho Chi Minh City, Vietnam are presented in this paper. The measurements were performed using a low-background proportional counters LB4200 manufactured by Canberra Company, Inc. Mean concentrations of gross alpha and beta activity were found to be 1.50 ± 0.38 Bq kg -1 to 84.25 ± 8.67 Bq kg -1 . In order to keep the recommended dose level, a recommended maximum intake of water spinach was proposed to be 6 kg fresh per year. The total annual committed effective dose due to natural radionuclides in water spinach samples was then found in range from 0.07 mSv y -1 to 0.82 mSv y -1 . The dose from 26.32% of samples exceeds the exemption mean dose criterion of 0.3 mSv y -1 but complies with the upper dose principle of 1 mSv y -1 provided in UNSCEAR 2008 report. The estimated soil-to-plant transfer factors for gross alpha and beta for water spinach samples were also presented. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Concentration of 3H in ground water and estimation of committed effective dose due to ground water ingestion in some places in the Maharashtra state, India.

    PubMed

    Reddy, P J; Bhade, S P D; Kolekar, R V; Singh, Rajvir; Pradeepkumar, K S

    2014-01-01

    The measurement of tritium in environmental samples requires highest possible sensitivity. In the present study, the authors have optimised the counting window for the analysis of (3)H in environmental samples using the recently installed Ultra Low Level Quantulus 1220 Liquid Scintillation Counting at BARC to improve the detection limit of the system. The optimised counting window corresponding to the highest figure of merit of 883.8 was found to be 20-162 channels. Different brands of packaged drinking waters were analysed to select a blank that would define the system background. The minimum detectable activity (MDA) achieved was 1.5 Bq l(-1) for a total counting time of 500 min. The concentration of tritium in well and bore well water samples collected from the villages of Pune, villages located at 1.8 km from Tarapur Atomic Power Station, Kolhapur and Ratnagiri, was analysed. The activity concentration ranged from 0.55 to 3.66 Bq l(-1). The associated age-dependant dose from water ingestion in the study area was estimated. The effective committed dose recorded for different age classes is negligible compared with World Health Organization and US Environmental Protection Agency dose guidelines.

  3. Committed effective dose determination in southern Brazilian cereal flours.

    PubMed

    Scheibel, V; Appoloni, C R

    2013-01-01

    The health impact of radionuclide ingestion from foodstuffs was evaluated by the committed effective doses determined in eight commercial samples of South-Brazilian cereal flours (soy, wheat, cornmeal, cassava, rye, oat, barley and rice flours). The radioactivity traces of (228)Th, (228)Ra, (226)Ra, (40)K, (7)Be and (137)Cs were measured by gamma-ray spectrometry employing an HPGe detector of 66 % relative efficiency. The efficiency curve has taken into account the differences in densities and chemical composition between the matrix and the certified sample. The highest concentration levels of (228)Th and (40)K were 3.5±0.4 and 1469±17 Bq kg(-1) for soy flour, respectively, within the 95 % confidence level. The lower limit of detection for (137)Cs ranged from 0.04 to 0.4 Bq kg(-1). The highest committed effective dose was 0.36 μSv.y(-1) for (228)Ra in cassava flour (adults). All committed effective doses determined at the present work were lower than the International Atomic Energy Agency dose limit of 1 mSv.y(-1), to the public exposure.

  4. WORKER INHALATION DOSE COEFFICIENTS FOR RADIONUCLIDES NOT PREVIOUSLY IDENTIFIED IN ICRP PUBLICATION 68

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McLaughlin, David A; Schwahn, Scott O

    2011-01-01

    While inhalation dose coefficients are provided for about 800 radionuclides in International Commission on Radiological Protection (ICRP) Publication 68, many radionuclides of practical dosimetric interest for facilities such as high-energy proton accelerators are not specifically addressed, nor are organ-specific dose coefficients tabulated. The ICRP Publication 68 methodology is used, along with updated radiological decay data and metabolic data, to identify committed equivalent dose coefficients [hT(50)] and committed effective dose coefficients [e(50)] for radionuclides produced at the Oak Ridge National Laboratory s Spallation Neutron Source.

  5. 24 CFR 884.105 - Maximum total ACC commitment and project account (private-owner/PHA projects).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Maximum total ACC commitment and..., Scope and Basic Policies § 884.105 Maximum total ACC commitment and project account (private-owner/PHA projects). (a) Maximum total ACC commitment. The maximum total annual contribution that may be contracted...

  6. 24 CFR 884.105 - Maximum total ACC commitment and project account (private-owner/PHA projects).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 4 2011-04-01 2011-04-01 false Maximum total ACC commitment and..., Scope and Basic Policies § 884.105 Maximum total ACC commitment and project account (private-owner/PHA projects). (a) Maximum total ACC commitment. The maximum total annual contribution that may be contracted...

  7. Assessment of ²¹⁰Po in Italian diet.

    PubMed

    Meli, Maria Assunta; Desideri, Donatella; Roselli, Carla; Feduzi, Laura

    2014-07-15

    This research was dedicated to the study, in the Italian daily diet, of the background activity concentration of (210)Po, a radionuclide with a high radiotoxicity. (210)Po was determined by alpha spectrometry. For food products of vegetable origin, the (210)Po activity concentration follows the trend: leafy vegetable>flour>rice>fruits>pasta>other vegetables>fruit vegetable; for those of animal origin: eggs>cheese>milk. The (210)Po activity concentration was also compared with that found by the same authors in meat, sea food, water and beverages in a previous study. The committed effective doses to individuals of three population groups (infants, children and adults) were 379, 222 and 151 μSv y(-1), respectively. The intake of foods of marine origin contributed about 67% of the total dose due to (210)Po ingestion. The effective dose, from (210)Po ingested by total diet, accounts for only 5-12% of the natural radiation exposure in Italy. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Protracted exposure to fallout: the Rongelap and Utirik experience.

    PubMed

    Lessard, E T; Miltenberger, R P; Cohn, S H; Musolino, S V; Conard, R A

    1984-03-01

    From June 1946 to August 1958, the U.S. Department of Defense and the U.S. Atomic Energy Commission (AEC) conducted nuclear weapons tests in the Northern Marshall Islands. On 1 March 1954, BRAVO, an above-ground test in the Castle series, produced high levels of radioactive material, some of which subsequently fell on Rongelap and Utirik Atolls due to an unexpected wind shift. On 3 March 1954, the inhabitants of these atolls were moved out of the affected area. They later returned to Utirik in June 1954 and to Rongelap in June 1957. Comprehensive environmental and personnel radiological monitoring programs were initiated in the mid 1950s by Brookhaven National Laboratory to ensure that body burdens of the exposed Marshallese subjects remained within AEC guidelines. Their body-burden histories and calculated activity ingestion rate patterns post-return are presented along with estimates of internal committed effective dose equivalents. External exposure data are also included. In addition, relationships between body burden or urine-activity concentration and declining continuous intake were developed. The implications of these studies are: (1) the dietary intake of 137Cs was a major component contributing to the committed effective dose equivalent for the years after the initial contamination of the atolls; (2) for persons whose diet included fish, 65Zn was a major component of committed effective dose equivalent during the first years post-return; (3) a decline in the daily activity ingestion rate greater than that resulting from radioactive decay of the source was estimated for 137Cs, 65Zn, 90Sr and 60Co; (4) the relative impact of each nuclide on the estimate of committed effective dose equivalent was dependent upon the time interval between initial contamination and rehabilitation; and (5) the internal committed effective dose equivalent exceeded the external dose equivalent by a factor of 1.1 at Utirik and 1.5 at Rongelap during the rehabitation period. Few reliable 239Pu measurements on human excreta were made. An analysis of the tentative data leads to the conclusion that a reliable estimate of committed effective dose equivalent requires further research.

  9. The effect of lifelong exercise dose on cardiovascular function during exercise

    PubMed Central

    Carrick-Ranson, Graeme; Hastings, Jeffrey L.; Bhella, Paul S.; Fujimoto, Naoki; Shibata, Shigeki; Palmer, M. Dean; Boyd, Kara; Livingston, Sheryl; Dijk, Erika

    2014-01-01

    An increased “dose” of endurance exercise training is associated with a greater maximal oxygen uptake (V̇o2max), a larger left ventricular (LV) mass, and improved heart rate and blood pressure control. However, the effect of lifelong exercise dose on metabolic and hemodynamic response during exercise has not been previously examined. We performed a cross-sectional study on 101 (69 men) seniors (60 yr and older) focusing on lifelong exercise frequency as an index of exercise dose. These included 27 who had performed ≤2 exercise sessions/wk (sedentary), 25 who performed 2–3 sessions/wk (casual), 24 who performed 4–5 sessions/wk (committed) and 25 who performed ≥6 sessions/wk plus regular competitions (Masters athletes) over at least the last 25 yr. Oxygen uptake and hemodynamics [cardiac output, stroke volume (SV)] were collected at rest, two levels of steady-state submaximal exercise, and maximal exercise. Doppler ultrasound measures of LV diastolic filling were assessed at rest and during LV loading (saline infusion) to simulate increased LV filling. Body composition, total blood volume, and heart rate recovery after maximal exercise were also examined. V̇o2max increased in a dose-dependent manner (P < 0.05). At maximal exercise, cardiac output and SV were largest in committed exercisers and Masters athletes (P < 0.05), while arteriovenous oxygen difference was greater in all trained groups (P < 0.05). At maximal exercise, effective arterial elastance, an index of ventricular-arterial coupling, was lower in committed exercisers and Masters athletes (P < 0.05). Doppler measures of LV filling were not enhanced at any condition, irrespective of lifelong exercise frequency. These data suggest that performing four or more weekly endurance exercise sessions over a lifetime results in significant gains in V̇o2max, SV, and heart rate regulation during exercise; however, improved SV regulation during exercise is not coupled with favorable effects on LV filling, even when the heart is fully loaded. PMID:24458750

  10. National survey on dose data analysis in computed tomography.

    PubMed

    Heilmaier, Christina; Treier, Reto; Merkle, Elmar Max; Alkhadi, Hatem; Weishaupt, Dominik; Schindera, Sebastian

    2018-05-28

    A nationwide survey was performed assessing current practice of dose data analysis in computed tomography (CT). All radiological departments in Switzerland were asked to participate in the on-line survey composed of 19 questions (16 multiple choice, 3 free text). It consisted of four sections: (1) general information on the department, (2) dose data analysis, (3) use of a dose management software (DMS) and (4) radiation protection activities. In total, 152 out of 241 Swiss radiological departments filled in the whole questionnaire (return rate, 63%). Seventy-nine per cent of the departments (n = 120/152) analyse dose data on a regular basis with considerable heterogeneity in the frequency (1-2 times per year, 45%, n = 54/120; every month, 35%, n = 42/120) and method of analysis. Manual analysis is carried out by 58% (n = 70/120) compared with 42% (n = 50/120) of departments using a DMS. Purchase of a DMS is planned by 43% (n = 30/70) of the departments with manual analysis. Real-time analysis of dose data is performed by 42% (n = 21/50) of the departments with a DMS; however, residents can access the DMS in clinical routine only in 20% (n = 10/50) of the departments. An interdisciplinary dose team, which among other things communicates dose data internally (63%, n = 76/120) and externally, is already implemented in 57% (n = 68/120) departments. Swiss radiological departments are committed to radiation safety. However, there is high heterogeneity among them regarding the frequency and method of dose data analysis as well as the use of DMS and radiation protection activities. • Swiss radiological departments are committed to and interest in radiation safety as proven by a 63% return rate of the survey. • Seventy-nine per cent of departments analyse dose data on a regular basis with differences in the frequency and method of analysis: 42% use a dose management software, while 58% currently perform manual dose data analysis. Of the latter, 43% plan to buy a dose management software. • Currently, only 25% of the departments add radiation exposure data to the final CT report.

  11. Natural radioactivity measurements and dosimetric evaluations in soil samples with a high content of NORM

    NASA Astrophysics Data System (ADS)

    Caridi, F.; Marguccio, S.; Durante, G.; Trozzo, R.; Fullone, F.; Belvedere, A.; D'Agostino, M.; Belmusto, G.

    2017-01-01

    In this article natural radioactivity measurements and dosimetric evaluations in soil samples contaminated by Naturally Occurring Radioactive Materials (NORM) are made, in order to assess any possible radiological hazard for the population and for workers professionally exposed to ionizing radiations. Investigated samples came from the district of Crotone, Calabria region, South of Italy. The natural radioactivity investigation was performed by high-resolution gamma-ray spectrometry. From the measured gamma spectra, activity concentrations were determined for 226Ra , 234-mPa , 224Ra , 228Ac and 40K and compared with their clearance levels for NORM. The total effective dose was calculated for each sample as due to the committed effective dose for inhalation and to the effective dose from external irradiation. The sum of the total effective doses estimated for all investigated samples was compared to the action levels provided by the Italian legislation (D.Lgs.230/95 and subsequent modifications) for the population members (0.3mSv/y) and for professionally exposed workers (1mSv/y). It was found to be less than the limit of no radiological significance (10μSv/y).

  12. The effect of lifelong exercise frequency on arterial stiffness.

    PubMed

    Shibata, Shigeki; Fujimoto, Naoki; Hastings, Jeffrey L; Carrick-Ranson, Graeme; Bhella, Paul S; Hearon, Christopher; Levine, Benjamin D

    2018-05-20

    This study examined the effect of different 'doses' of lifelong (>25 years) exercise on arterial stiffening (a hallmark of vascular ageing) in older adults. There are clear dose-dependent effects of lifelong exercise training on human arterial stiffness that vary according to the site and size of the arteries. Similar to what we have observed previously with ventricular stiffening, 4-5 days week -1 of committed exercise over a lifetime are necessary to preserve 'youthful' vascular compliance, especially of the large central arteries. Casual exercise training of two to three times per week may be sufficient for middle-sized arteries like the carotid to minimize arterial stiffening with ageing. However, there is little effect of exercise training on the small-sized peripheral arteries at any dose. Central arterial stiffness increases with sedentary ageing. While near-daily, vigorous lifelong (>25 years) endurance exercise training prevents arterial stiffening with ageing, this rigorous routine of exercise training over a lifetime is impractical for most individuals. The aim was to examine whether a less frequent 'dose' of lifelong exercise training (four to five sessions per week for > 30 min) that is consistent with current physical activity recommendations elicits similar benefits on central arterial stiffening with ageing. A cross-sectional examination of 102 seniors (>60 years old) who had a consistent lifelong exercise history was performed. Subjects were stratified into four groups based on exercise frequency as an index of exercise 'dose': sedentary: fewer than two sessions per week; casual exercisers: two to three sessions per week; committed exercisers: four to five sessions per week; and Masters athletes: six to seven sessions per week plus regular competitions. Detailed measurements of arterial stiffness and left ventricular afterload were collected. Biological aortic age and central pulse wave velocity were younger in committed exercisers and Masters athletes compared to sedentary seniors. Total arterial compliance index (TACi) was lower, while carotid β-stiffness index and effective arterial elastance were higher in sedentary seniors compared to the other groups. There appeared to be a dose-response threshold for carotid β-stiffness index and TACi. Peripheral arterial stiffness was not significantly different among the groups. These data suggest that four to five weekly exercise sessions over a lifetime is associated with reduced central arterial stiffness in the elderly. A less frequent dose of lifelong exercise (two to three sessions per week) is associated with decreased ventricular afterload and peripheral resistance, while peripheral arterial stiffness is unaffected by any dose of exercise. © 2018 The Authors. The Journal of Physiology © 2018 The Physiological Society.

  13. Measurement of 238U and 232Th in Petrol, Gas-oil and Lubricant Samples by Using Nuclear Track Detectors and Resulting Radiation Doses to the Skin of Mechanic Workers.

    PubMed

    Misdaq, M A; Chaouqi, A; Ouguidi, J; Touti, R; Mortassim, A

    2015-10-01

    Workers in repair shops of vehicles (cars, buses, truck, etc.) clean carburetors, check fuel distribution, and perform oil changes and greasing. To explore the exposure pathway of (238)U and (232)Th and its decay products to the skin of mechanic workers, these radionuclides were measured inside petrol, gas-oil, and lubricant material samples by means of CR-39 and LR-115 type II solid state nuclear track detectors (SSNTDs), and corresponding annual committed equivalent doses to skin were determined. The maximum total equivalent effective dose to skin due to the (238)U and (232)Th series from the application of different petrol, gas-oil, and lubricant samples by mechanic workers was found equal to 1.2 mSv y(-1) cm(-2).

  14. 32 CFR 218.3 - Dose reconstruction methodology.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... effects of shot-specific parameters such as weapon type and yield, neutron and gamma output, source and... specific personnel activities. Due to the range of activities, times, geometries, shielding, and weapon... that could have led to atypical doses. Radiation dose from neutrons and dose commitments due to inhaled...

  15. 32 CFR 218.3 - Dose reconstruction methodology.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... effects of shot-specific parameters such as weapon type and yield, neutron and gamma output, source and... specific personnel activities. Due to the range of activities, times, geometries, shielding, and weapon... that could have led to atypical doses. Radiation dose from neutrons and dose commitments due to inhaled...

  16. 32 CFR 218.3 - Dose reconstruction methodology.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... effects of shot-specific parameters such as weapon type and yield, neutron and gamma output, source and... specific personnel activities. Due to the range of activities, times, geometries, shielding, and weapon... that could have led to atypical doses. Radiation dose from neutrons and dose commitments due to inhaled...

  17. Circulating Hematopoietic Stem and Progenitor Cells in Aging Atomic Bomb Survivors.

    PubMed

    Kyoizumi, Seishi; Kubo, Yoshiko; Misumi, Munechika; Kajimura, Junko; Yoshida, Kengo; Hayashi, Tomonori; Imai, Kazue; Ohishi, Waka; Nakachi, Kei; Young, Lauren F; Shieh, Jae-Hung; Moore, Malcolm A; van den Brink, Marcel R M; Kusunoki, Yoichiro

    2016-01-01

    It is not yet known whether hematopoietic stem and progenitor cells (HSPCs) are compromised in the aging population of atomic bomb (A-bomb) survivors after their exposure nearly 70 years ago. To address this, we evaluated age- and radiation-related changes in different subtypes of circulating HSPCs among the CD34-positive/lineage marker-negative (CD34(+)Lin(-)) cell population in 231 Hiroshima A-bomb survivors. We enumerated functional HSPC subtypes, including: cobblestone area-forming cells; long-term culture-initiating cells; erythroid burst-forming units; granulocyte and macrophage colony-forming units; and T-cell and natural killer cell progenitors using cell culture. We obtained the count of each HSPC subtype per unit volume of blood and the proportion of each HSPC subtype in CD34(+)Lin(-) cells to represent the lineage commitment trend. Multivariate analyses, using sex, age and radiation dose as variables, showed significantly decreased counts with age in the total CD34(+)Lin(-) cell population and all HSPC subtypes. As for the proportion, only T-cell progenitors decreased significantly with age, suggesting that the commitment to the T-cell lineage in HSPCs continuously declines with age throughout the lifetime. However, neither the CD34(+)Lin(-) cell population, nor HSPC subtypes showed significant radiation-induced dose-dependent changes in counts or proportions. Moreover, the correlations of the proportions among HSPC subtypes in the survivors properly revealed the hierarchy of lineage commitments. Taken together, our findings suggest that many years after exposure to radiation and with advancing age, the number and function of HSPCs in living survivors as a whole may have recovered to normal levels.

  18. Circulating Hematopoietic Stem and Progenitor Cells in Aging Atomic Bomb Survivors

    PubMed Central

    Kyoizumi, Seishi; Kubo, Yoshiko; Misumi, Munechika; Kajimura, Junko; Yoshida, Kengo; Hayashi, Tomonori; Imai, Kazue; Ohishi, Waka; Nakachi, Kei; Young, Lauren F.; Shieh, Jae-Hung; Moore, Malcolm A.; van den Brink, Marcel R. M.; Kusunoki, Yoichiro

    2016-01-01

    It is not yet known whether hematopoietic stem and progenitor cells (HSPCs) are compromised in the aging population of atomic bomb (A-bomb) survivors after their exposure nearly 70 years ago. To address this, we evaluated age- and radiation-related changes in different subtypes of circulating HSPCs among the CD34-positive/lineage marker-negative (CD34+Lin− ) cell population in 231 Hiroshima A-bomb survivors. We enumerated functional HSPC subtypes, including: cobblestone area-forming cells; long-term culture-initiating cells; erythroid burst-forming units; granulocyte and macrophage colony-forming units; and T-cell and natural killer cell progenitors using cell culture. We obtained the count of each HSPC subtype per unit volume of blood and the proportion of each HSPC subtype in CD34+Lin− cells to represent the lineage commitment trend. Multivariate analyses, using sex, age and radiation dose as variables, showed significantly decreased counts with age in the total CD34+Lin− cell population and all HSPC subtypes. As for the proportion, only T-cell progenitors decreased significantly with age, suggesting that the commitment to the T-cell lineage in HSPCs continuously declines with age throughout the lifetime. However, neither the CD34+Lin− cell population, nor HSPC subtypes showed significant radiation-induced dose-dependent changes in counts or proportions. Moreover, the correlations of the proportions among HSPC subtypes in the survivors properly revealed the hierarchy of lineage commitments. Taken together, our findings suggest that many years after exposure to radiation and with advancing age, the number and function of HSPCs in living survivors as a whole may have recovered to normal levels. PMID:26720799

  19. Determination of the uncertainties in radiation doses from ingestion of strontium-90

    NASA Astrophysics Data System (ADS)

    Apostoaei, Andrei Iulian

    Quantification of the uncertainties in the internal dosimetry is important because it can impact the outcome of dose reconstruction, risk assessment or epidemiological studies. This research focused on determination of the uncertainties in the dose factors from a single ingestion of 90Sr by adults, and analyzed the changes with age and the effect of gender. The uncertainties in the estimated dose factors are a factor of 6 for the bone surface, 5 for the red bone marrow, 2.5 for bladder and stomach, 2.2 for the small intestine, 2.1 for the upper large intestine and 2.7 for the lower large intestine. For the rest of the organs the uncertainty is a factor of 3. Only four parameters of the biokinetic model showed an age-dependency within the adult age group: the fractional transfers of strontium from plasma to cortical and trabecular bone, and the removal rates from the cortical and trabecular bone, respectively. When age-dependent biokinetic parameters were used, the estimated dose-factors are very close to the dose factors obtained using age-independent kinetics (within 40%). Thus, the dose factors based on age-independent parameters should suffice for most practical purposes. The dose factors and the associated uncertainties were also calculated as a function of age-at-exposure and attained age. These age dependent curves can be used for estimating doses from continuous intakes, or doses delivered over a limited portion of time. In addition to the committed dose, an expected dose is also estimated in this work. The expected dose is calculated using the dose rate weighted by the probability of surviving up to the age when the dose-rate is delivered. For exposure at young ages the expected dose and the committed dose are similar, but the committed dose decreases to zero when exposure occurs close to age 70, while the expected dose has elevated values pass age 70. No gender differences were found for bone surface, for red bone marrow, and the large intestine. The doses to the soft tissues for females are larger by 20% than the doses for males, because of the differences in the whole-body mass between males and females.

  20. Dose Calculation For Accidental Release Of Radioactive Cloud Passing Over Jeddah

    NASA Astrophysics Data System (ADS)

    Alharbi, N. D.; Mayhoub, A. B.

    2011-12-01

    For the evaluation of doses after the reactor accident, in particular for the inhalation dose, a thorough knowledge of the concentration of the various radionuclide in air during the passage of the plume is required. In this paper we present an application of the Gaussian Plume Model (GPM) to calculate the atmospheric dispersion and airborne radionuclide concentration resulting from radioactive cloud over the city of Jeddah (KSA). The radioactive cloud is assumed to be emitted from a reactor of 10 MW power in postulated accidental release. Committed effective doses (CEDs) to the public at different distance from the source to the receptor are calculated. The calculations were based on meteorological condition and data of the Jeddah site. These data are: pasquill atmospheric stability is the class B and the wind speed is 2.4m/s at 10m height in the N direction. The residence time of some radionuclides considered in this study were calculated. The results indicate that, the values of doses first increase with distance, reach a maximum value and then gradually decrease. The total dose received by human is estimated by using the estimated values of residence time of each radioactive pollutant at different distances.

  1. The study of equivalent dose of uranium in long bean (V. U. Sesquipedalis) and the effect on human

    NASA Astrophysics Data System (ADS)

    Rashid, Nur Shahidah Abdul; Yoshandi, Tengku Mohammad; Majid, Sukiman Sarmania Amran Ab.; Mohamed, Faizal; Siong, Khoo Kok

    2016-01-01

    In the case of accidental release of Uranium-238 (238U) radionuclides in a nuclear facility or in the environment, internal contamination by either acute or chronic exposure has the potential to induce both radiological and chemical toxic effects. A study was conducted to estimate the 238U radionuclide concentration in the long beans using Induced Coupled Mass Plasma-Spectrometry (ICP-MS). 238U radionuclide is a naturally occurring radioactive material that can be found in soil and can be transferred to the long bean (Vigna unguiculata subsp. Sesquapedalis) directly or indirectly via water or air. Kidney and liver are the major sites of deposition of 238U radionuclide. The obtained dose exposed in the liver and kidney is used to assess the safety level for public intake of 238U radionuclide from the consumption of long beans. The concentration of 238U radionuclide measured in long bean samples was 0.0226 ± 0.0009 mg/kg. Total activity of 238U radionuclide was 0.0044 ± 0.0002 Bq/day with the daily intake of 0.3545 ± 0.0143 µg/day and the annual committed effective dose due to ingestion of 238U radionuclide in long beans was 0.2230 ± 0.0087 µSv/year. The committed equivalent dose of 238U radionuclide from the assessment in the liver and kidney are 0.4198 ± 0.0165 nSv and 10.9335 ± 0.4288 nSv. The risk of cancer of 238U radionuclide was determined to be (86.0466 ± 3.3748) × 10-9. Thus, the results concluded that 238U radionuclide in local long beans was in the permitted level and safe to consume without posing any significant radiological threat to population.

  2. The Long Winding Road of Opioid Substitution Therapy Implementation in South-East Asia: Challenges to Scale Up

    PubMed Central

    Reid, Gary; Sharma, Mukta; Higgs, Peter

    2014-01-01

    The South-East Asia Region contains an estimated 400,000-500,000 people who inject drugs (PWID). HIV prevalence among PWID is commonly 20% or higher in Indonesia, Thailand, Myanmar and some regions of India. Opioid substitution therapy (OST) is an important HIV prevention intervention in this part of the world. However, key challenges and barriers to scale up of OST exist, including: pervasive stigma and discrimination towards PWID; criminalisation of drug use overshadowing a public health response; lack of political will and national commitment; low financial investment; focus towards traditional treatment models of detoxification and rehabilitation; inadequate dosing of OST; and poor monitoring and evaluation of programmes. Our review of local evidence highlights that OST can be successful within the Asian context. Such evidence should be utilised more widely to advocate for policy change and increased political commitment to ensure OST reaches substantially more drug users. Significance for public health Several countries in the World Health Organization South-East Asia Region can be commended for introducing opioid substitution therapy (OST) to address the ongoing HIV epidemic among people who inject drugs (PWID). Local evidence shows OST is an effective drug treatment approach in the Asian context given sufficient technical and institutional support. However, despite much progress, the number of OST dispensing sites and recipients remains totally inadequate in terms of impact upon the current HIV epidemic among PWID. Ongoing advocacy is needed if countries are to achieve the WHO’s target of 40% of PWID being dosed with OST. Greater political commitment a strengthened policy environment, capacity building for OST clinics, lessening the criminalisation of drug use and promoting a public health response will give many more PWID access to OST and slow the advance of the HIV epidemic. PMID:25170509

  3. Retrospective study of the iodine-131 contamination of workers in the radiopharmaceutical industry.

    PubMed

    Gaburo, J C; Lipsztein, J L; Rabelo, D M; Stabin, M

    2003-01-01

    A dose reconstruction study was performed for personnel occupationally exposed to 131I in radiopharmaceutical production, during the years 1981 to 1994, with the objective of estimating committed effective doses and critically reviewing the main causes of their exposures. The workers were selected from a group responsible for the production, labelling and distribution of all radiopharmaceutical material in Brazil. Best estimates of intakes and doses were derived from the examination of the individual monitoring records and the reports from the radiation protection supervisor, complemented by interviews with the workers and with radiation protection officers. Over this time period workers had chronic as well as acute intakes of 131I. Committed effective doses were found to be dependent on the task performed by the worker and the site of operation and inversely correlated with the amounts of iodine handled. Intakes in general were a consequence of inadequate radiation protection control.

  4. Daily radionuclide ingestion and internal radiation doses in Aomori prefecture, Japan.

    PubMed

    Ohtsuka, Yoshihito; Kakiuchi, Hideki; Akata, Naofumi; Takaku, Yuichi; Hisamatsu, Shun'ichi

    2013-10-01

    To assess internal annual dose in the general public in Aomori Prefecture, Japan, 80 duplicate cooked diet samples, equivalent to the food consumed over a 400-d period by one person, were collected from 100 volunteers in Aomori City and the village of Rokkasho during 2006–2010 and were analyzed for 11 radionuclides. To obtain average rates of ingestion of radionuclides, the volunteers were selected from among office, fisheries, agricultural, and livestock farm workers. Committed effective doses from ingestion of the diet over a 1-y period were calculated from the analytical results and from International Commission on Radiological Protection dose coefficients; for 40K, an internal effective dose rate from the literature was used. Fisheries workers had significantly higher combined internal annual dose than the other workers, possibly because of high rates of ingestion of marine products known to have high 210Po concentrations. The average internal dose rate, weighted by the numbers of households in each worker group in Aomori Prefecture, was estimated at 0.47 mSv y-1. Polonium-210 contributed 49% of this value. The sum of committed effective dose rates for 210Po, 210Pb, 228Ra, and 14C and the effective dose rate of 40K accounted for approximately 99% of the average internal dose rate.

  5. 10 CFR 20.1003 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... assessment of dose equivalent by the use of devices designed to be worn by an individual; (2) The assessment... equipment) means devices designed to be worn by a single individual for the assessment of dose equivalent... radionuclide in a year by the reference man that would result in a committed effective dose equivalent of 5...

  6. 10 CFR 20.1003 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... assessment of dose equivalent by the use of devices designed to be worn by an individual; (2) The assessment... equipment) means devices designed to be worn by a single individual for the assessment of dose equivalent... radionuclide in a year by the reference man that would result in a committed effective dose equivalent of 5...

  7. 10 CFR 20.1003 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... assessment of dose equivalent by the use of devices designed to be worn by an individual; (2) The assessment... equipment) means devices designed to be worn by a single individual for the assessment of dose equivalent... radionuclide in a year by the reference man that would result in a committed effective dose equivalent of 5...

  8. 10 CFR 20.1003 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... assessment of dose equivalent by the use of devices designed to be worn by an individual; (2) The assessment... equipment) means devices designed to be worn by a single individual for the assessment of dose equivalent... radionuclide in a year by the reference man that would result in a committed effective dose equivalent of 5...

  9. 10 CFR 20.1003 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... assessment of dose equivalent by the use of devices designed to be worn by an individual; (2) The assessment... equipment) means devices designed to be worn by a single individual for the assessment of dose equivalent... radionuclide in a year by the reference man that would result in a committed effective dose equivalent of 5...

  10. ICRP Publication 137: Occupational Intakes of Radionuclides: Part 3.

    PubMed

    Paquet, F; Bailey, M R; Leggett, R W; Lipsztein, J; Marsh, J; Fell, T P; Smith, T; Nosske, D; Eckerman, K F; Berkovski, V; Blanchardon, E; Gregoratto, D; Harrison, J D

    2017-12-01

    The 2007 Recommendations of the International Commission on Radiological Protection (ICRP, 2007) introduced changes that affect the calculation of effective dose, and implied a revision of the dose coefficients for internal exposure, published previously in the Publication 30 series (ICRP, 1979, 1980, 1981, 1988) and Publication 68 (ICRP, 1994). In addition, new data are now available that support an update of the radionuclide-specific information given in Publications 54 and 78 (ICRP, 1988a, 1997b) for the design of monitoring programmes and retrospective assessment of occupational internal doses. Provision of new biokinetic models, dose coefficients, monitoring methods, and bioassay data was performed by Committee 2, Task Group 21 on Internal Dosimetry, and Task Group 4 on Dose Calculations. A new series, the Occupational Intakes of Radionuclides (OIR) series, will replace the Publication 30 series and Publications 54, 68, and 78. OIR Part 1 has been issued (ICRP, 2015), and describes the assessment of internal occupational exposure to radionuclides, biokinetic and dosimetric models, methods of individual and workplace monitoring, and general aspects of retrospective dose assessment. OIR Part 2 (ICRP, 2016), this current publication and upcoming publications in the OIR series (Parts 4 and 5) provide data on individual elements and their radioisotopes, including information on chemical forms encountered in the workplace; a list of principal radioisotopes and their physical half-lives and decay modes; the parameter values of the reference biokinetic model; and data on monitoring techniques for the radioisotopes encountered most commonly in workplaces. Reviews of data on inhalation, ingestion, and systemic biokinetics are also provided for most of the elements. Dosimetric data provided in the printed publications of the OIR series include tables of committed effective dose per intake (Sv Bq−1 intake) for inhalation and ingestion, tables of committed effective dose per content (Sv Bq−1 measurement) for inhalation, and graphs of retention and excretion data per Bq intake for inhalation. These data are provided for all absorption types and for the most common isotope(s) of each element. The electronic annex that accompanies the OIR series of publications contains a comprehensive set of committed effective and equivalent dose coefficients, committed effective dose per content functions, and reference bioassay functions. Data are provided for inhalation, ingestion, and direct input to blood. This third publication in the series provides the above data for the following elements: ruthenium (Ru), antimony (Sb), tellurium (Te), iodine (I), caesium (Cs), barium (Ba), iridium (Ir), lead (Pb), bismuth (Bi), polonium (Po), radon (Rn), radium (Ra), thorium (Th), and uranium (U).

  11. ICRP Publication 134: Occupational Intakes of Radionuclides: Part 2.

    PubMed

    Paquet, F; Bailey, M R; Leggett, R W; Lipsztein, J; Fell, T P; Smith, T; Nosske, D; Eckerman, K F; Berkovski, V; Ansoborlo, E; Giussani, A; Bolch, W E; Harrison, J D

    2016-12-01

    The 2007 Recommendations of the International Commission on Radiological Protection (ICRP, 2007) introduced changes that affect the calculation of effective dose, and implied a revision of the dose coefficients for internal exposure, published previously in the Publication 30 series (ICRP, 1979, 1980, 1981, 1988b) and Publication 68 (ICRP, 1994b). In addition, new data are available that support an update of the radionuclide-specific information given in Publications 54 and 78 (ICRP, 1988a, 1997b) for the design of monitoring programmes and retrospective assessment of occupational internal doses. Provision of new biokinetic models, dose coefficients, monitoring methods, and bioassay data was performed by Committee 2, Task Group 21 on Internal Dosimetry, and Task Group 4 on Dose Calculations. A new series, the Occupational Intakes of Radionuclides (OIR) series, will replace the Publication 30 series and Publications 54, 68, and 78. Part 1 of the OIR series has been issued (ICRP, 2015), and describes the assessment of internal occupational exposure to radionuclides, biokinetic and dosimetric models, methods of individual and workplace monitoring, and general aspects of retrospective dose assessment. The following publications in the OIR series (Parts 2–5) will provide data on individual elements and their radioisotopes, including information on chemical forms encountered in the workplace; a list of principal radioisotopes and their physical half-lives and decay modes; the parameter values of the reference biokinetic model; and data on monitoring techniques for the radioisotopes encountered most commonly in workplaces. Reviews of data on inhalation, ingestion, and systemic biokinetics are also provided for most of the elements. Dosimetric data provided in the printed publications of the OIR series include tables of committed effective dose per intake (Sv per Bq intake) for inhalation and ingestion, tables of committed effective dose per content (Sv per Bq measurement) for inhalation, and graphs of retention and excretion data per Bq intake for inhalation. These data are provided for all absorption types and for the most common isotope(s) of each element. The electronic annex that accompanies the OIR series of reports contains a comprehensive set of committed effective and equivalent dose coefficients, committed effective dose per content functions, and reference bioassay functions. Data are provided for inhalation, ingestion, and direct input to blood. The present publication provides the above data for the following elements: hydrogen (H), carbon (C), phosphorus (P), sulphur (S), calcium (Ca), iron (Fe), cobalt (Co), zinc (Zn), strontium (Sr), yttrium (Y), zirconium (Zr), niobium (Nb), molybdenum (Mo), and technetium (Tc).

  12. Weldon Spring Site environmental report for calendar year 1993. Weldon Springs Site Remedial Action Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-05-01

    This Site Environmental Report for Calendar Year 1993 describes the environmental monitoring programs at the Weldon Spring Site Remedial Action Project (WSSRAP). The objectives of these programs are to assess actual or potential exposure to contaminant effluents from the project area by providing public use scenarios and dose estimates, to demonstrate compliance with Federal and State permitted levels, and to summarize trends and/or changes in contaminant concentrations from environmental monitoring program. In 1993, the maximum committed dose to a hypothetical individual at the chemical plant site perimeter was 0.03 mrem (0.0003 mSv). The maximum committed dose to a hypothetical individualmore » at the boundary of the Weldon Spring Quarry was 1.9 mrem (0.019 mSv). These scenarios assume an individual walking along the perimeter of the site-once a day at the chemical plant/raffinate pits and twice a day at the quarry-250 days per year. This hypothetical individual also consumes fish, sediment, and water from lakes and other bodies of water in the area. The collective dose, based on an effected population of 112,000 was 0.12 person-rem (0.0012 person-Sv). This calculation is based on recreational use of the August A. Busch Memorial Conservation Area and the Missouri Department of Conservation recreational trail (the Katy Trail) near the quarry. These estimates are below the U.S. Department of Energy requirement of 100 mrem (I mSv) annual committed effective dose equivalent for all exposure pathways. Results from air monitoring for the National Emission Standards for Hazardous Air Pollutants (NESHAPs) program indicated that the estimated dose was 0.38 mrem, which is below the U.S. Environmental Protection Agency (EPA) standard of 10 mrem per year.« less

  13. Career commitment and job performance of Jordanian nurses.

    PubMed

    Mrayyan, Majd T; Al-Faouri, Ibrahim

    2008-01-01

    Career commitment and job performance are complex phenomena that have received little attention in nursing research. A survey was used to assess nurses' career commitment and job performance, and the relationship between the two concepts. Predictors of nurses' career commitment and job performance were also studied. A convenience sample of 640 Jordanian registered nurses was recruited from 24 teaching, governmental, and private hospitals. Nurses "agreed" on the majority of statements about career commitment, and they reported performing "well" their jobs. Using total scores, nurses were equal in their career commitment but they were different in their job performance; the highest mean was scored for nurses in private hospitals. Using the individual items of subscales, nurses were willing to be involved, on their own time, in projects that would benefit patient care. The correlation of the total scores of nurses' career commitment and job performance revealed the presence of a significant and positive relationship (r = .457). Nurses' job performance, gender, and marital status were the best predictors of nurses' career commitment: they explained 21.8% of variance of nurses' career commitment. Nurses' career commitment, time commitment, marital status, and years of experience in nursing were the best predictors of nurses' job performance: they explained 25.6% of variance of nurses' job performance. The lowest reported means of nurses' job performance require managerial interventions.

  14. An analysis of commitment strategies in planning: The details

    NASA Technical Reports Server (NTRS)

    Minton, Steven; Bresina, John; Drummond, Mark; Philips, Andrew B.

    1991-01-01

    We compare the utility of different commitment strategies in planning. Under a 'least commitment strategy', plans are represented as partial orders and operators are ordered only when interactions are detected. We investigate claims of the inherent advantages of planning with partial orders, as compared to planning with total orders. By focusing our analysis on the issue of operator ordering commitment, we are able to carry out a rigorous comparative analysis of two planners. We show that partial-order planning can be more efficient than total-order planning, but we also show that this is not necessarily so.

  15. Analysis of 238U, 232Th, 222Rn, and 220Rn in different medical drug preparations by using CR-39 and LR-115 typE II SSNTDs and resulting radiation doses to adult patients.

    PubMed

    Misdaq, M A; Karime, M

    2009-01-01

    Uranium (238U) and thorium (232Th) concentrations as well as radon (222Rn) and thoron (220Rn) alpha activities per unit volume have been measured inside 18 medical drugs (4 liquid and 14 solid materials), widely prescribed by doctors to the Moroccan adult patients, by using CR-39 and LR-115 type II solid state nuclear track detectors (SSNTDs). The measured 238U, 232Th, 222Rn, and 220Rn concentrations ranged from (4.7 +/- 0.1) mBq L-1 to (14.3 +/- 0.7) mBq L-1, (0.32 +/- 0.02) mBq L-1 to (2.7 +/- 0.2) mBq L-1, (4.7 +/- 0.2) Bq L-1 to (14.3 +/- 0.7) Bq L-1, and (0.32 +/- 0.02) Bq L-1 to (2.7 +/- 0.2) Bq L-1 for the medical drug samples studied, respectively. These radionuclides were also measured inside the preparations of the solid medical drugs studied. The influence of the drinking water nature and pollution on the concentrations of these radionuclides inside the considered medical drug preparations was investigated. Annual committed equivalent doses due to 238U, 232Th, and 222Rn were evaluated in the human body compartments of adult patients from the ingestion of the medical drug preparations studied. The maximum total committed effective dose due to 238U, 232Th, and 222Rn from the ingestion of the studied medical drug preparations, prepared from unpolluted waters, by adult patients was found equal to 1.44 microSv y.

  16. THE CHALLENGE OF CIEMAT INTERNAL DOSIMETRY SERVICE FOR ACCREDITATION ACCORDING TO ISO/IEC 17025 STANDARD, FOR IN VIVO AND IN VITRO MONITORING AND DOSE ASSESSMENT OF INTERNAL EXPOSURES.

    PubMed

    Lopez, M A; Martin, R; Hernandez, C; Navarro, J F; Navarro, T; Perez, B; Sierra, I

    2016-09-01

    The accreditation of an Internal Dosimetry Service (IDS) according to ISO/IEC 17025 Standard is a challenge. The aim of this process is to guarantee the technical competence for the monitoring of radionuclides incorporated in the body and for the evaluation of the associated committed effective dose E(50). This publication describes the main accreditation issues addressed by CIEMAT IDS regarding all the procedures involving good practice in internal dosimetry, focussing in the difficulties to ensure the traceability in the whole process, the appropriate calculation of detection limit of measurement techniques, the validation of methods (monitoring and dose assessments), the description of all the uncertainty sources and the interpretation of monitoring data to evaluate the intake and the committed effective dose. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Air contamination measurements for the evaluation of internal dose to workers in nuclear medicine departments

    NASA Astrophysics Data System (ADS)

    De Massimi, B.; Bianchini, D.; Sarnelli, A.; D'Errico, V.; Marcocci, F.; Mezzenga, E.; Mostacci, D.

    2017-11-01

    Radionuclides handled in nuclear medicine departments are often characterized by high volatility and short half-life. It is generally difficult to monitor directly the intake of these short-lived radionuclides in hospital staff: this makes measuring air contamination of utmost interest. The aim of the present work is to provide a method for the evaluation of internal doses to workers in nuclear medicine, by means of an air activity sampling detector, to ensure that the limits prescribed by the relevant legislation are respected. A continuous air sampling system measures isotope concentration with a Nal(TI) detector. Energy efficiency of the system was assessed with GEANT4 and with known activities of 18F. Air is sampled in a number of areas of the nuclear medicine department of the IRST-IRCCS hospital (Meldola- Italy). To evaluate committed doses to hospital staff involved (doctors, technicians, nurses) different exposure situations (rooms, times, radionuclides etc) were considered. After estimating the intake, the committed effective dose has been evaluated, for the different radionuclides, using the dose coefficients mandated by the Italian legislation. Error propagation for the estimated intake and personal dose has been evaluated, starting from measurement statistics.

  18. New Stochastic Annual Limits on Intake for Selected Radionuclides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carbaugh, Eugene H.

    Annual limits on intake (ALI) have historically been tabulated by the International Commission on Radiological Protection (e.g., ICRP 1979, 1961) and also by the Environmental Protection Agency (EPA 1988). These compilations have been rendered obsolete by more recent ICRP dosimetry methods, and, rather than provide new ALIs, the ICRP has opted instead to provide committed dose coefficients from which an ALI can be determined by a user for a specific set of conditions. The U.S. Department of Energy historically has referenced compilations of ALIs and has defined their method of calculation in its radiation protection regulation (10 CFDR 835), butmore » has never provided a specific compilation. Under June 2007 amendments to 10 CFR 835, ALIs can be calculated by dividing an appropriate dose limit, either 5-rem (0.05 Sv) effective dose or 50 rem (0.5 Sv) equivalent dose to an individual organ or tissue, by an appropriate committed dose coefficient. When based on effective dose, the ALI is often referred to as a stochastic annual limit on intake (SALI), and when based on the individual organ or tissue equivalent limit, it has often been called a deterministic annual limit on intake (DALI).« less

  19. The study of equivalent dose of uranium in long bean (V. U. Sesquipedalis) and the effect on human

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rashid, Nur Shahidah Abdul; Yoshandi, Tengku Mohammad; Majid, Sukiman Sarmania Amran Ab.

    In the case of accidental release of Uranium-238 ({sup 238}U) radionuclides in a nuclear facility or in the environment, internal contamination by either acute or chronic exposure has the potential to induce both radiological and chemical toxic effects. A study was conducted to estimate the {sup 238}U radionuclide concentration in the long beans using Induced Coupled Mass Plasma-Spectrometry (ICP-MS). {sup 238}U radionuclide is a naturally occurring radioactive material that can be found in soil and can be transferred to the long bean (Vigna unguiculata subsp. Sesquapedalis) directly or indirectly via water or air. Kidney and liver are the major sitesmore » of deposition of {sup 238}U radionuclide. The obtained dose exposed in the liver and kidney is used to assess the safety level for public intake of {sup 238}U radionuclide from the consumption of long beans. The concentration of {sup 238}U radionuclide measured in long bean samples was 0.0226 ± 0.0009 mg/kg. Total activity of {sup 238}U radionuclide was 0.0044 ± 0.0002 Bq/day with the daily intake of 0.3545 ± 0.0143 µg/day and the annual committed effective dose due to ingestion of {sup 238}U radionuclide in long beans was 0.2230 ± 0.0087 µSv/year. The committed equivalent dose of {sup 238}U radionuclide from the assessment in the liver and kidney are 0.4198 ± 0.0165 nSv and 10.9335 ± 0.4288 nSv. The risk of cancer of {sup 238}U radionuclide was determined to be (86.0466 ± 3.3748) × 10-9. Thus, the results concluded that {sup 238}U radionuclide in local long beans was in the permitted level and safe to consume without posing any significant radiological threat to population.« less

  20. Measurement of the concentration of radon gas in the Toirano's caves (Liguria).

    PubMed

    Bruzzone, Diego; Bussallino, Massimo; Castello, Gianrico; Maggiolo, Stefano; Rossi, Daniela

    2006-01-01

    The radioactive gas radon, intermediate term of the decay series of uranium and thorium, is the main contamination source of underground places and may be a risk for high concentration and long exposure time. European and Italian law requires radon concentration to be measured in workplaces and, if the "action level" of 500 Bq/m3 is reached, proper actions must be made in order to decrease the dose commitment. Considering natural showcaves or artificial cavities open to public, the exposition of the visitors is frequently small, due to the short residence time, but accompanying people, remaining underground for long time, may be subject to appreciable dose and the radon concentration should therefore be monitored. The high humidity in natural caves may impair the use of some measuring devices. Therefore, different detection methods were compared (ZnS scintillation counters, E-PERM electret ionisation chambers, cellulose nitrate alpha-track dosimeters) to select the best procedure for long-term investigation. The LR-115 (Kodak) alpha-track dosimeters were insensitive to humidity and permitted to monitor a great number of places at the same time. Measurements have been carried out in the speleological and archaeological site of the Toirano's Caves (Savona, Liguria, Italy) and several points were monitored for two years. Radon concentration strongly depends on the site and changes during the year, due to the difference between internal and external temperature. The maximum dose commitment during the visitors tour, considering the average yearly value of radon concentration, was found to be between 1.5 and 4 microSv. It was found that no risk exists for visitors, but the evaluation of the dose absorbed by the guides and their classification according to the radiation protection law requires a complete monitoring of the average yearly concentration of radon and of the total time spent by each worker into the cave.

  1. The influence of particle size distribution on dose conversion factors for radon progeny in the underground excavations of hard coal mine.

    PubMed

    Skubacz, Krystian; Wojtecki, Łukasz; Urban, Paweł

    2016-10-01

    In Polish underground mines, hazards caused by enhanced natural radioactivity occur. The sources of radiation exposure are short-lived radon decay products, mine waters containing radium 226 Ra and 228 Ra and the radioactive sediments that can precipitate out of these waters. For miners, the greatest exposure is usually due to short-lived radon decay products. The risk assessment is based on the measurement of the total potential alpha energy concentration (PAEC) and the evaluation of the related dose by using the dose conversion factor as recommended by relevant legal requirements. This paper presents the results of measurements of particle size distributions of ambient aerosols in an underground hard coal mine, the assessment of the radioactive particle size distribution of the short-lived radon decay products and the corresponding values of dose conversion factors. The measurements of the ambient airborne particle size distribution were performed in the range from a few nanometers to about 20 μm. The study therefore included practically the whole class of respirable particles. The results showed that the high concentration of ultrafine and fine aerosols measured can significantly affect the value of the dose conversion factors, and consequently the corresponding committed effective dose, to which the miners can be exposed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Estimates of internal-dose equivalent from inhalation and ingestion of selected radionuclides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dunning, D.E.

    1982-01-01

    This report presents internal radiation dose conversion factors for radionuclides of interest in environmental assessments of nuclear fuel cycles. This volume provides an updated summary of estimates of committed dose equivalent for radionuclides considered in three previous Oak Ridge National Laboratory (ORNL) reports. Intakes by inhalation and ingestion are considered. The International Commission on Radiological Protection (ICRP) Task Group Lung Model has been used to simulate the deposition and retention of particulate matter in the respiratory tract. Results corresponding to activity median aerodynamic diameters (AMAD) of 0.3, 1.0, and 5.0 ..mu..m are given. The gastorintestinal (GI) tract has been representedmore » by a four-segment catenary model with exponential transfer of radioactivity from one segment to the next. Retention of radionuclides in systemic organs is characterized by linear combinations of decaying exponential functions, recommended in ICRP Publication 30. The first-year annual dose rate, maximum annual dose rate, and fifty-year dose commitment per microcurie intake of each radionuclide is given for selected target organs and the effective dose equivalent. These estimates include contributions from specified source organs plus the systemic activity residing in the rest of the body; cross irradiation due to penetrating radiations has been incorporated into these estimates. 15 references.« less

  3. Evaluation of metrics for benchmarking antimicrobial use in the UK dairy industry.

    PubMed

    Mills, Harriet L; Turner, Andrea; Morgans, Lisa; Massey, Jonathan; Schubert, Hannah; Rees, Gwen; Barrett, David; Dowsey, Andrew; Reyher, Kristen K

    2018-03-31

    The issue of antimicrobial resistance is of global concern across human and animal health. In 2016, the UK government committed to new targets for reducing antimicrobial use (AMU) in livestock. Although a number of metrics for quantifying AMU are defined in the literature, all give slightly different interpretations. This paper evaluates a selection of metrics for AMU in the dairy industry: total mg, total mg/kg, daily dose and daily course metrics. Although the focus is on their application to the dairy industry, the metrics and issues discussed are relevant across livestock sectors. In order to be used widely, a metric should be understandable and relevant to the veterinarians and farmers who are prescribing and using antimicrobials. This means that clear methods, assumptions (and possible biases), standardised values and exceptions should be published for all metrics. Particularly relevant are assumptions around the number and weight of cattle at risk of treatment and definitions of dose rates and course lengths; incorrect assumptions can mean metrics over-represent or under-represent AMU. The authors recommend that the UK dairy industry work towards the UK-specific metrics using the UK-specific medicine dose and course regimens as well as cattle weights in order to monitor trends nationally. © British Veterinary Association (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Auditability In The U.S. Navy: A Knowledge Assessment Of The Contracting Workforce

    DTIC Science & Technology

    2016-12-01

    DOD committed more money than all other government agencies combined. In total, the U.S. Department of Justice in its annual evaluation stated that...290 billion. The DOD committed more money than all other government agencies combined. In total, the U.S. Department of Justice in its annual...opportunity for fraud to be committed is an inherent risk whenever money is involved. This risk increases if there are poor processes in place. This

  5. Seasonal influenza vaccine dose distribution in 195 countries (2004-2013): Little progress in estimated global vaccination coverage.

    PubMed

    Palache, Abraham; Oriol-Mathieu, Valerie; Fino, Mireli; Xydia-Charmanta, Margarita

    2015-10-13

    Seasonal influenza is an important disease which results in 250,000-500,000 annual deaths worldwide. Global targets for vaccination coverage rates (VCRs) in high-risk groups are at least 75% in adults ≥65 years and increased coverage in other risk groups. The International Federation of Pharmaceutical Manufacturers and Associations Influenza Vaccine Supply (IFPMA IVS) International Task Force developed a survey methodology in 2008, to assess the global distribution of influenza vaccine doses as a proxy for VCRs. This paper updates the previous survey results on absolute numbers of influenza vaccine doses distributed between 2004 and 2013 inclusive, and dose distribution rates per 1000 population, and provides a qualitative assessment of the principal enablers and barriers to seasonal influenza vaccination. The two main findings from the quantitative portion of the survey are the continued negative trend for dose distribution in the EURO region and the perpetuation of appreciable differences in scale of dose distribution between WHO regions, with no observed convergence in the rates of doses distributed per 1000 population over time. The main findings from the qualitative portion of the survey were that actively managing the vaccination program in real-time and ensuring political commitment to vaccination are important enablers of vaccination, whereas insufficient access to vaccination and lack of political commitment to seasonal influenza vaccination programs are likely contributing to vaccination target failures. In all regions of the world, seasonal influenza vaccination is underutilized as a public health tool. The survey provides evidence of lost opportunity to protect populations against potentially serious influenza-associated disease. We call on the national and international public health communities to re-evaluate their political commitment to the prevention of the annual influenza disease burden and to develop a systematic approach to improve vaccine distribution equitably. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Romantic Relationship Commitment and Its Linkages with Commitment to Parents and Friends during Adolescence

    ERIC Educational Resources Information Center

    De Goede, Irene H. A.; Branje, Susan; van Duin, Jet; VanderValk, Inge E.; Meeus, Wim

    2012-01-01

    This five-wave longitudinal study examines linkages between adolescents' perceptions of romantic relationship commitment and the development of adolescents' perceptions of commitment to parents and friends. A total of 218 early-to-middle adolescents (39.0 percent boys) and 185 middle-to-late adolescents (30.8 percent boys) participated.…

  7. 10 CFR 63.111 - Performance objectives for the geologic repository operations area through permanent closure.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... of the deep dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose equivalent may not exceed 0.15 Sv (15... TEDE (hereafter referred to as “dose”) to any real member of the public located beyond the boundary of...

  8. 10 CFR 63.111 - Performance objectives for the geologic repository operations area through permanent closure.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... of the deep dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose equivalent may not exceed 0.15 Sv (15... TEDE (hereafter referred to as “dose”) to any real member of the public located beyond the boundary of...

  9. 10 CFR 63.111 - Performance objectives for the geologic repository operations area through permanent closure.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... of the deep dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose equivalent may not exceed 0.15 Sv (15... TEDE (hereafter referred to as “dose”) to any real member of the public located beyond the boundary of...

  10. 10 CFR 63.111 - Performance objectives for the geologic repository operations area through permanent closure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... of the deep dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose equivalent may not exceed 0.15 Sv (15... TEDE (hereafter referred to as “dose”) to any real member of the public located beyond the boundary of...

  11. Effects of Low-Dose Mindfulness-Based Stress Reduction (MBSR-ld) on Working Adults

    ERIC Educational Resources Information Center

    Klatt, Maryanna D.; Buckworth, Janet; Malarkey, William B.

    2009-01-01

    Mindfulness-based stress reduction (MBSR) has produced behavioral, psychological, and physiological benefits, but these programs typically require a substantial time commitment from the participants. This study assessed the effects of a shortened (low-dose [ld]) work-site MBSR intervention (MBSR-ld) on indicators of stress in healthy working…

  12. Radiation doses to individuals due to ²³⁸U, ²³²Th and ²²²Rn from the immersion in thermal waters and to radon progeny from the inhalation of air inside thermal stations.

    PubMed

    Misdaq, M A; Ghilane, M; Ouguidi, J; Outeqablit, K

    2012-11-01

    In Morocco, thermal waters have been used for decades for the treatment of various diseases. To explore the exposure pathway of (238)U, (232)Th and (222)Rn to the skin of bathers from the immersion in thermal waters, these radionuclides were measured inside waters collected from different Moroccan thermal springs, by means of CR-39 and LR-115 type II solid-state nuclear track detectors (SSNTDs), and corresponding annual committed effective doses to skin were determined. Accordingly, to assess radiation dose due to radon short-lived decay products from the inhalation of air by individuals, concentrations of these radionuclides were measured in indoor air of two thermal stations by evaluating mean critical angles of etching of the CR-39 and LR-115 II SSNTDs. Committed effective doses due to the short-lived radon decay products (218)Po and (214)Po by bathers and working personnel inside the thermal stations studied were determined.

  13. HADOC: a computer code for calculation of external and inhalation doses from acute radionuclide releases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strenge, D.L.; Peloquin, R.A.

    The computer code HADOC (Hanford Acute Dose Calculations) is described and instructions for its use are presented. The code calculates external dose from air submersion and inhalation doses following acute radionuclide releases. Atmospheric dispersion is calculated using the Hanford model with options to determine maximum conditions. Building wake effects and terrain variation may also be considered. Doses are calculated using dose conversion factor supplied in a data library. Doses are reported for one and fifty year dose commitment periods for the maximum individual and the regional population (within 50 miles). The fractional contribution to dose by radionuclide and exposure modemore » are also printed if requested.« less

  14. Organizational Climate and Teacher Commitment

    ERIC Educational Resources Information Center

    Douglas, Stephen Michael

    2010-01-01

    This study examined the relationship of school climate and teacher commitment in elementary schools in Alabama. A total of 67 elementary schools were surveyed and 1353 teachers voluntarily participated in the study. The instruments used in this study were the Organizational Climate Index (OCI) and the Organizational Commitment Questionnaire (OCQ).…

  15. The radiological exposure of man from radioactivity in the Baltic Sea.

    PubMed

    Nielsen, S P; Bengtson, P; Bojanowsky, R; Hagel, P; Herrmann, J; Ilus, E; Jakobson, E; Motiejunas, S; Panteleev, Y; Skujina, A; Suplinska, M

    1999-09-30

    A radiological assessment has been carried out considering discharges of radioactivity to the Baltic Sea marine environment since 1950. The sources of radioactivity that have been evaluated are atmospheric nuclear-weapons fallout, fallout from the Chernobyl accident in 1986, discharges of radionuclides from Sellafield and La Hague transported into the Baltic Sea, and discharges of radionuclides from nuclear installations located in the Baltic Sea area. Dose rates from man-made radioactivity to individual members of the public (critical groups) have been calculated based on annual intake of seafood and beach occupancy time. The dose rates to individuals from the regions of the Bothnian Sea and Gulf of Finland are predicted to be larger than from any other area in the Baltic Sea due to the pattern of Chernobyl fallout. The dose rates are predicted to have peaked in 1986 at a value of 0.2 mSv year-1. Collective committed doses to members of the public have been calculated based on fishery statistics and predicted concentrations of radionuclides in biota and coastal sediments. The total collective dose from man-made radioactivity in the Baltic Sea is estimated at 2600 manSv, of which approximately two-thirds originate from Chernobyl fallout, approximately one-quarter from atmospheric nuclear-weapons fallout, approximately 8% from European reprocessing facilities, and approximately 0.04% from nuclear installations bordering the Baltic Sea area. An assessment of small-scale dumping of low-level radioactive waste in the Baltic Sea in the 1960s by Sweden and the Soviet Union has showed that doses to man from these activities are negligible. Dose rates and doses from natural radioactivity dominate except for the year 1986 where dose rates to individuals from Chernobyl fallout in some regions of the Baltic Sea approached those from natural radioactivity.

  16. PB-210 concentrations in cigarettes tobaccos and radiation doses to the smokers.

    PubMed

    Tahir, S N A; Alaamer, A S

    2008-01-01

    Cigarette smoking is a source of radiation exposure due to the concentrations of natural radionuclides in the tobacco leaves. From the health point of view, measurement of (210)Pb and (210)Po contents in cigarette tobacco is important to assess the radiological effects associated with the tobacco smoking for the smokers. In the present study, activity concentrations of (210)Pb, which is a (210)Po precursor in the (238)U-decay series, were measured in cigarette tobaccos. Samples of nine different commonly sold brands of cigarette tobaccos were analysed by employing a planar high purity germanium (HPGe) low background detector. Activity concentrations of (210)Pb were measured from its gamma peak at 47 keV. Mean activity concentration of (210)Pb was measured to be 13 +/- 4 Bq kg(-1) from all samples analysed. The annual committed effective dose for a smoker and the collective committed effective dose corresponding to annual cigarettes production were estimated to be 64 +/- 20 microSv and 0.6 x 10(2) man-Sv, respectively.

  17. Thrombopoietin to replace megakaryocyte-derived growth factor: impact on stem and progenitor cells during ex vivo expansion of CD34+ cells mobilized in peripheral blood.

    PubMed

    Duchez, Pascale; Chevaleyre, Jean; Vlaski, Marija; Dazey, Bernard; Bijou, Fontanet; Lafarge, Xavier; Milpied, Noël; Boiron, Jean-Michel; Ivanovic, Zoran

    2011-02-01

    The first protocol of ex vivo expansion that enabled almost total abrogation of postmyeloablative chemotherapy neutropenia was based on a three-cytokine cocktail (stem cell factor [SCF], granulocyte-colony-stimulating factor [G-CSF], pegylated-megakaryocyte growth and development factor [PEG-MGDF]) in a serum-free medium. Since the clinical-grade molecule MGDF is no longer available on the market, we evaluated its substitution by thrombopoietin (TPO). CD34+ cells of myeloma patients were expanded for 10 days in serum-free cultures with SCF, G-CSF, or MGDF (100 ng/mL) or with TPO (2.5, 10, 20, 50, and 100 ng/mL) instead of MGDF. Day 10 amplifications of total nucleated cells, CD34+ cells, committed progenitors (CFCs), the capacity of engraftment of NOD/SCID mice (SCID repopulating cells [SRCs]), and the immunophenotype of cells in expansion product (CD13, CD14, CD33, CD41, CD61) were analyzed. TPO in doses of 2.5 and 10 ng/mL exhibits an effect comparable to that of MGDF (100 ng/mL) on total, CD34+, and CFCs amplification. Compared to MGDF, TPO (starting at 10 ng/mL) enhances two- to threefold the percentage of megakaryocyte lineage cells (CD41+ and CD61+). Finally, TPO maintains or even enhances (depending on dose) SRC activity. The use of TPO instead of MGDF in our protocol is feasible without any negative effect on progenitor cell expansion. Furthermore, applied in dose of 10 or 100 ng/mL it could enhance both the stem cell activity and the percentage of megakaryocyte lineage cells in expansion product. © 2010 American Association of Blood Banks.

  18. 24 CFR 883.604 - Maximum annual commitment and project account.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... annual commitment. The maximum annual contribution that may be contracted for in the ACC is the total of... annual commitment exceeds the amount actually paid out under the ACC each year. Payments will be made... specifically approved by the Secretary. (2) Whenever a HUD-approved estimate of required payments under the ACC...

  19. 24 CFR 883.604 - Maximum annual commitment and project account.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... annual commitment. The maximum annual contribution that may be contracted for in the ACC is the total of... annual commitment exceeds the amount actually paid out under the ACC each year. Payments will be made... specifically approved by the Secretary. (2) Whenever a HUD-approved estimate of required payments under the ACC...

  20. Dose relations between goal setting, theory-based correlates of goal setting and increases in physical activity during a workplace trial.

    PubMed

    Dishman, Rod K; Vandenberg, Robert J; Motl, Robert W; Wilson, Mark G; DeJoy, David M

    2010-08-01

    The effectiveness of an intervention depends on its dose and on moderators of dose, which usually are not studied. The purpose of the study is to determine whether goal setting and theory-based moderators of goal setting had dose relations with increases in goal-related physical activity during a successful workplace intervention. A group-randomized 12-week intervention that included personal goal setting was implemented in fall 2005, with a multiracial/ethnic sample of employees at 16 geographically diverse worksites. Here, we examined dose-related variables in the cohort of participants (N = 664) from the 8 worksites randomized to the intervention. Participants in the intervention exceeded 9000 daily pedometer steps and 300 weekly minutes of moderate-to-vigorous physical activity (MVPA) during the last 6 weeks of the study, which approximated or exceeded current public health guidelines. Linear growth modeling indicated that participants who set higher goals and sustained higher levels of self-efficacy, commitment and intention about attaining their goals had greater increases in pedometer steps and MVPA. The relation between change in participants' satisfaction with current physical activity and increases in physical activity was mediated by increases in self-set goals. The results show a dose relation of increased physical activity with changes in goal setting, satisfaction, self-efficacy, commitment and intention, consistent with goal-setting theory.

  1. Factors that impact clinical laboratory scientists' commitment to their work organizations.

    PubMed

    Bamberg, Richard; Akroyd, Duane; Moore, Ti'eshia M

    2008-01-01

    To assess the predictive ability of various aspects of the work environment for organizational commitment. A questionnaire measuring three dimensions of organizational commitment along with five aspects of work environment and 10 demographic and work setting characteristics was sent to a national, convenience sample of clinical laboratory professionals. All persons obtaining the CLS certification by NCA from January 1, 1997 to December 31, 2006. Only respondents who worked full-time in a clinical laboratory setting were included in the database. Levels of affective, normative, and continuance organizational commitment, organizational support, role clarity, role conflict, transformational leadership behavior of supervisor, and organizational type, total years work experience in clinical laboratories, and educational level of respondents. Questionnaire items used either a 7-point or 5-point Likert response scale. Based on multiple regression analysis for the 427 respondents, organizational support and transformational leadership behavior were found to be significant positive predictors of affective and normative organizational commitment. Work setting (non-hospital laboratory) and total years of work experience in clinical laboratories were found to be significant positive predictors of continuance organizational commitment. Overall the organizational commitment levels for all three dimensions were at the neutral rating or below in the slightly disagree range. The results indicate a less than optimal level of organizational commitment to employers, which were predominantly hospitals, by CLS practitioners. This may result in continuing retention problems for hospital laboratories. The results offer strategies for improving organizational commitment via the significant predictors.

  2. 24 CFR 880.503 - Maximum annual commitment and project account.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... may be contracted for in the ACC is the total of the contract rents and utility allowances for all... commitment exceeds the amount actually paid out under the Contract or ACC each year. Payments will be made... the Contract or ACC for a fiscal year exceeds the maximum annual commitment and would cause the amount...

  3. 24 CFR 880.503 - Maximum annual commitment and project account.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... may be contracted for in the ACC is the total of the contract rents and utility allowances for all... commitment exceeds the amount actually paid out under the Contract or ACC each year. Payments will be made... the Contract or ACC for a fiscal year exceeds the maximum annual commitment and would cause the amount...

  4. 210Po, 210Pb, 40K and 137Cs in edible wild berries and mushrooms and ingestion doses to man from high consumption rates of these wild foods.

    PubMed

    Gwynn, Justin P; Nalbandyan, Anna; Rudolfsen, Geir

    2013-02-01

    This paper discusses activity concentrations of (210)Po, (210)Pb, (40)K and (137)Cs in edible wild berries and mushrooms collected from Øvre Dividalen national park, Northern Norway and derives committed effective ingestion doses to man based on high consumption rates of these wild foods. Edible wild berries and mushrooms accumulated similar levels of (210)Pb, but mushrooms accumulated higher levels of (210)Po and (40)K than berries. There appears to be a clear difference in the ability of Leccinum spp. of fungi to accumulate (210)Po and/or translocate (210)Po to mushrooms compared to Russula spp. of fungi. Activity concentrations of (137)Cs in edible wild berries and mushrooms from Øvre Dividalen national park reflected the lower levels of fallout of this radionuclide in Northern Norway compared to more central areas following the Chernobyl accident. For mushrooms, ingestion doses are dominated by (210)Po, while for berries, (40)K is typically the main contributor to dose. Based on high consumption rates, ingestion doses arising from the combination of (210)Po, (210)Pb and (40)K were up to 0.05 mSv/a for berries and 0.50 mSv/a for mushrooms. Consumption of such wild foods may result in a significant contribution to total annual doses when consumed in large quantities, particularly when selecting mushrooms species that accumulate high activity concentrations of (210)Po. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Organizational Commitment of Teachers: A Meta-Analysis Study for the Effect of Gender and Marital Status in Turkey

    ERIC Educational Resources Information Center

    Çogaltay, Nazim

    2015-01-01

    This meta-analysis summarizes the influence of Turkish teacher's gender and marital status on their perception of organizational commitment. In total, 30 independent research studies conducted across the country are investigated to analyze the relations between gender and organizational commitment, i.e., a sample group of 11,724 participants. In…

  6. Who gets the most out of cognitive behavioral therapy for anxiety disorders? The role of treatment dose and patient engagement.

    PubMed

    Glenn, Daniel; Golinelli, Daniela; Rose, Raphael D; Roy-Byrne, Peter; Stein, Murray B; Sullivan, Greer; Bystritksy, Alexander; Sherbourne, Cathy; Craske, Michelle G

    2013-08-01

    The present study explored treatment dose and patient engagement as predictors of treatment outcome in cognitive behavioral therapy (CBT) for anxiety disorders. Measures of high versus low treatment dose and high versus low patient engagement in CBT were compared as predictors of 12- and 18-month outcomes for patients being treated for anxiety disorders with CBT (with or without concurrent pharmacotherapy) in primary care settings as part of a randomized controlled effectiveness trial of the Coordinated Anxiety Learning and Management (CALM) intervention. Measures of dose (attendance, exposure completion) and engagement in CBT (homework adherence, commitment) were collected throughout treatment, and blinded follow-up phone assessments of outcome measures (12-item Brief Symptom Inventory, Patient Health Questionnaire 8, Sheehan Disability Scale) were completed at 12 and 18 months. Propensity score weighting controlled for baseline differences in demographics and symptom severity between patients with high and low dose and engagement. These analyses included the 439 patients who selected CBT as treatment modality. Completing exposures, having high attendance, and being more adherent to completing homework predicted better outcomes across all measures at 12 and 18 months, and high CBT commitment predicted better outcomes on all measures at 18 months. This study found that higher treatment dose and patient engagement in CBT for anxiety disorders were stable and robust predictors of greater reductions in anxiety symptoms, depression symptoms, and functional disability. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  7. Job and organizational determinants of nursing home employee commitment, job satisfaction and intent to turnover.

    PubMed

    Karsh, B; Booske, B C; Sainfort, F

    2005-08-15

    The purpose of this study was to examine whether job characteristics, the work environment, participation in quality improvement activities and facility quality improvement environment predicted employee commitment and job satisfaction in nursing homes, and whether those same predictors and commitment and satisfaction predicted turnover intention. A total of 6,584 nursing home employees from 76 nursing homes in a midwestern state participated. A self-administered questionnaire was used to collect the data. The results supported the hypotheses that job and organizational factors predicted commitment and satisfaction while commitment and satisfaction predicted turnover intentions. The implications for retaining nursing home employees are discussed.

  8. How can core self-evaluations influence job burnout? The key roles of organizational commitment and job satisfaction.

    PubMed

    Peng, Jiaxi; Li, Dongdong; Zhang, Zhenjiang; Tian, Yu; Miao, Danmin; Xiao, Wei; Zhang, Jiaxi

    2016-01-01

    This study aimed to explore how core self-evaluations influenced job burnout and mainly focused on the confirmation of the mediator roles of organizational commitment and job satisfaction. A total of 583 female nurses accomplished the Core Self-Evaluation Scale, Organizational Commitment Scale, Minnesota Satisfaction Questionnaire, and Maslach Burnout Inventory-General Survey. The results revealed that core self-evaluations, organizational commitment, job satisfaction, and job burnout were significantly correlated with each other. Structural equation modeling indicated that core self-evaluations can significantly influence job burnout and are completely mediated by organizational commitment and job satisfaction. © The Author(s) 2014.

  9. Who Gets the Most Out of Cognitive-Behavioral Therapy for Anxiety Disorders?

    PubMed Central

    Glenn, Daniel; Golinelli, Daniela; Rose, Raphael D.; Roy-Byrne, Peter; Stein, Murray B.; Sullivan, Greer; Bystritksy, Alexander; Sherbourne, Cathy; Craske, Michelle G.

    2013-01-01

    Objective The present study explored treatment dose and patient engagement as predictors of treatment outcome in cognitive behavioral therapy (CBT) for anxiety disorders. Method Measures of high versus low treatment dose, and high versus low patient engagement in CBT were compared as predictors of 12 and 18 month outcomes for patients being treated for anxiety disorders with CBT (with or without concurrent pharmacotherapy) in primary care settings as part of a randomized controlled effectiveness trial of the Coordinated Anxiety Learning and Management (CALM) intervention. Measures of dose (attendance, exposure completion) and engagement in CBT (homework adherence, commitment) were collected throughout treatment, and blinded follow-up phone assessments of outcome measures (12-item Brief Symptom Inventory, Patient Health Questionnaire 8, Sheehan Disability Scale) were completed at 12 and 18 months. Propensity score weighting controlled for baseline differences in demographics and symptom severity between patients with high and low dose and engagement. These analyses included the 439 patients that selected CBT as treatment modality. Results Completing exposures, high attendance, and being more homework adherent predicted better outcomes across all measures at 12 and 18 months, and high CBT commitment predicted better outcomes on all measures at 18 months. Conclusions This study found that higher treatment dose and patient engagement in CBT for anxiety disorders were stable and robust predictors of greater reductions in anxiety symptoms, depression symptoms, and functional disability. PMID:23750465

  10. Identity Processes and Parent-Child and Sibling Relationships in Adolescence: A Five-Wave Multi-Informant Longitudinal Study.

    PubMed

    Crocetti, Elisabetta; Branje, Susan; Rubini, Monica; Koot, Hans M; Meeus, Wim

    2017-01-01

    The purpose of this study was to examine reciprocal associations between identity processes (commitment, in-depth exploration, and reconsideration of commitment) and dimensions (support, negative interaction, and power) of maternal, paternal, and sibling relationships. A total of 497 Dutch families including 14-years-old adolescents (56.9% males), their fathers, mothers, and siblings, for a total of 1,988 respondents, participated in a five-wave longitudinal study. Cross-lagged analyses indicated that commitment and in-depth exploration predicted improvements in family relationships (unidirectional effects), whereas reconsideration of commitment was predicted by low levels of maternal support and worsened the quality of the paternal relationship (reciprocal effects). These results were not moderated by adolescents' gender and sibling characteristics. Theoretical and practical implications are discussed. © 2016 The Authors. Child Development © 2016 Society for Research in Child Development, Inc.

  11. Environmental consequences of postulate plutonium releases from Atomics International's Nuclear Materials Development Facility (NMDF), Santa Susana, California, as a result of severe natural phenomena

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jamison, J.D.; Watson, E.C.

    1982-02-01

    Potential environmental consequences in terms of radiation dose to people are presented for postulated plutonium releases caused by severe natural phenomena at the Atomics International's Nuclear Materials Development Facility (NMDF), in the Santa Susana site, California. The severe natural phenomena considered are earthquakes, tornadoes, and high straight-line winds. Plutonium deposition values are given for significant locations around the site. All important potential exposure pathways are examined. The most likely 50-year committed dose equivalents are given for the maximum-exposed individual and the population within a 50-mile radius of the plant. The maximum plutonium deposition values likely to occur offsite are alsomore » given. The most likely calculated 50-year collective committed dose equivalents are all much lower than the collective dose equivalent expected from 50 years of exposure to natural background radiation and medical x-rays. The most likely maximum residual plutonium contamination estimated to be deposited offsite following the earthquake, and the 150-mph and 170-mph tornadoes are above the Environmental Protection Agency's (EPA) proposed guideline for plutonium in the general environment of 0.2 ..mu..Ci/m/sup 2/. The deposition values following the 110-mph and the 130-mph tornadoes are below the EPA proposed guideline.« less

  12. Environmental consequences of postulated plutonium releases from General Electric Company Vallecitos Nuclear Center, Vallecitos, California, as a result of severe natural phenomena

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jamison, J.D.; Watson, E.C.

    1980-11-01

    Potential environmental consequences in terms of radiation dose to people are presented for postulated plutonium releases caused by severe natural phenomena at the General Electric Company Vallecitos Nuclear Center, Vallecitos, California. The severe natural phenomena considered are earthquakes, tornadoes, and high straight-line winds. Maximum plutonium deposition values are given for significant locations around the site. All important potential exposure pathways are examined. The most likely 50-year committed dose equivalents are given for the maximum-exposed individual and the population within a 50-mile radius of the plant. The maximum plutonium deposition values likely to occur offsite are also given. The most likelymore » calculated 50-year collective committed dose equivalents are all much lower than the collective dose equivalent expected from 50 years of exposure to natural background radiation and medical x-rays. The most likely maximum residual plutonium contamination estimated to be deposited offsite following the earthquakes, and the 180-mph and 230-mph tornadoes are above the Environmental Protection Agency's (EPA) proposed guideline for plutonium in the general environment of 0.2 ..mu..Ci/m/sup 2/. The deposition values following the 135-mph tornado are below the EPA proposed guidelines.« less

  13. 131I INTERNAL CONTAMINATION AND COMMITTED DOSE ASSESSMENT AMONG NUCLEAR MEDICINE MEDICAL PERSONNEL.

    PubMed

    Brudecki, K; Kluczewska-Galka, A; Mróz, T; Jarzab, B; Zagrodzki, P; Janowski, P

    2018-05-01

    This study presents 131I thyroid activity measurements of 56 employees of the Department of Nuclear Medicine and Endocrine Oncology, Centre for Oncology in Gliwice. The research instrument was a whole-body spectrometer. In 44 out of 56 examined staff members, the determined 131I activity was found to be above the detection limit. The measured activities ranged from 6 ± 2 to 457 ± 118 Bq. The maximum estimated committed effective dose reached was 1.5 mSv/y. The results were compared with previous measurements conducted in another Polish nuclear medical unit. From this comparison, we can see that radiological safety among nuclear medicine personnel can be improved by appropriate work organisation. Reducing exposure of workers can be achieved by properly organised turnovers concerning the most vulnerable worksites. In addition, to lower the radiation risk, it is essential to comply strictly with the isolation regime for the patients.

  14. Organizational commitment, work environment conditions, and life satisfaction among Iranian nurses.

    PubMed

    Vanaki, Zohreh; Vagharseyyedin, Seyyed Abolfazl

    2009-12-01

    Employee commitment to the organization is a crucial issue in today's health-care market. In Iran, few studies have sought to evaluate the factors that contribute to forms of commitment. The aim of this study was to investigate the relationship between nurses' organizational commitment, work environment conditions, and life satisfaction. A cross-sectional design was utilized. Questionnaires were distributed to all the staff nurses who had permanent employment (with at least 2 years of experience in nursing) in the five hospitals affiliated to Birjand Medical Sciences University. Two hundred and fifty participants returned completed questionnaires. Most were female and married. The correlation of the total scores of nurses' affective organizational commitment and work environment conditions indicated a significant and positive relationship. Also, a statistically significant relationship was found between affective organizational commitment and life satisfaction. The implementation of a comprehensive program to improve the work conditions and life satisfaction of nurses could enhance their organizational commitment.

  15. 210-Polonium studies in some environmental and biological matrices of Domiasiat uranium deposit area, West Khasi Hills, Meghalaya, India.

    PubMed

    Marbaniang, Deswyn G; Poddar, Raj K; Nongkynrih, Phlis; Khathing, Darlando T

    2010-03-01

    The study was performed using a silicon surface barrier alpha spectrometer at Bhabha Atomic Research Centre, Mumbai, India. Through the study, the observed (210)Po activity in water sample from different locations in the Domiasiat area ranges from 0.04 to 0.69 Bq/l. The daily and annual intake of (210)Po through water was also estimated and the mean value of 0.72 and 263.61 Bq, respectively, were observed. It is observed that the effective doses through water were higher than the World Health Organization recommended dose of 0.05 mSv/year. The total annual effective doses through terrestrial ingestion for all the locations was studied and the mean annual effective dose was observed to be 0.315 mSv, which, when compared to the worldwide and the Indian values, was observed to be slightly higher. The mean activity in soil is found to be 124.8 +/-5.7 Bq/kg and in meat the activity is 0.43 +/-0.05 Bq/kg. In fishes, an activity of 0.48 +/-0.07 Bq/kg in Garra lamta, 0.29 +/-0.02 Bq/kg in Neolissocheilus hexaganolepis, and 3.3 +/-0.1 Bq/kg in Macrobrachium sp. is observed. Activity concentration in plant samples was analyzed and the activity ranges from 0.020 +/-0.002 to 9.69 +/-0.35 Bq/kg. Committed effective dose by the adult population of the Domiasiat area through intake of (210)Po through these food items was also determined and compared with the Indian average value and the worldwide average value.

  16. Air concentrations of /sup 239/Pu and /sup 240/Pu and potential radiation doses to persons living near Pu-contaminated areas in Palomares, Spain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iranzo, E.; Salvador, S.; Iranzo, C.E.

    1987-04-01

    On 17 January 1966, an accident during a refueling operation resulted in the destruction of an air force KC-135 tanker and a B-52 bomber carrying four thermonuclear weapons. Two weapons, whose parachutes opened, were found intact. The others experienced non-nuclear explosion with some burning and release of the fissile fuel at impact. Joint efforts by the United States and Spain resulted in remedial action and a long-term program to monitor the effectiveness of the cleanup. Air concentrations of /sup 239/Pu and /sup 240/Pu have been continuously monitored since the accident. The average annual air concentration for each location was usedmore » to estimate committed dose equivalents for individuals living and working around the air sampling stations. The average annual /sup 239/Pu and /sup 240/Pu air concentrations during the 15-y period corresponding to 1966-1980 and the potential committed dose equivalents for various tissues due to the inhalation of the /sup 239/Pu and /sup 240/Pu average annual air concentration during this period are shown and discussed in the report.« less

  17. Organizational identification and commitment: correlates of sense of belonging and affective commitment.

    PubMed

    Dávila, Ma Celeste; Jiménez García, Gemma

    2012-03-01

    The general purpose of this work is to analyze the overlap between organizational identification and commitment. Specifically, our study focuses on the analysis of the differences and similarities between sense of belonging (a dimension of organizational identification) and affective commitment (a dimension of organizational commitment). In order to do this, we analyzed their discriminant validity and raised their relationship with variables that previous research had showed like precedent and subsequent variables of them: value congruence, perceived support, organizational citizenship behavior, and intention to continue in the organization. A total of 292 people at one organization completed surveys measuring the variables previously described. The results showed that sense of belonging and affective commitment are different concepts and they have different relationships with relation to precedent and subsequent variables. Affective commitment seems to be more useful than sense of belonging to predict organizational citizenship behavior aimed at the organization and intention to continue. Some practical implications are described.

  18. Why Adoption of Standards Matters

    ERIC Educational Resources Information Center

    Journal of Staff Development, 2016

    2016-01-01

    A total of 39 states have adopted, adapted, or endorsed the Standards for Professional Learning, including the standards issued in 2011 (labeled in red) and those published earlier (labeled in blue). Making a commitment to the standards is a commitment to continuous learning for all educators in a school.

  19. The impact of psychological capital on job burnout of Chinese nurses: the mediator role of organizational commitment.

    PubMed

    Peng, Jiaxi; Jiang, Xihua; Zhang, Jiaxi; Xiao, Runxuan; Song, Yunyun; Feng, Xi; Zhang, Yan; Miao, Danmin

    2013-01-01

    Nursing has a high risk of job burnout, but only a few studies have explored its influencing factors from an organizational perspective. The present study explores the impact of psychological capital on job burnout by investigating the mediating effect of organizational commitment on this relationship. A total of 473 female nurses from four large general hospitals in Xi'an City of China were selected as participants. Data were collected via the Psychological Capital Questionnaire, the Maslach Burnout Inventory-General Survey, and the Organizational Commitment Scale. Both psychological capital and organizational commitment were significantly correlated to job burnout. Structural equation modelling indicated that organizational commitment partially mediated the relationship between psychological capital and job burnout. The final model revealed a significant path from psychological capital to job burnout through organizational commitment. These findings extended prior reports and shed some light on the influence of psychological capital on job burnout.

  20. Assessing pediatrics residents' mathematical skills for prescribing medication: a need for improved training.

    PubMed

    Glover, Mark L; Sussmane, Jeffrey B

    2002-10-01

    To evaluate residents' skills in performing basic mathematical calculations used for prescribing medications to pediatric patients. In 2001, a test of ten questions on basic calculations was given to first-, second-, and third-year residents at Miami Children's Hospital in Florida. Four additional questions were included to obtain the residents' levels of training, specific pediatrics intensive care unit (PICU) experience, and whether or not they routinely double-checked doses and adjusted them for each patient's weight. The test was anonymous and calculators were permitted. The overall score and the score for each resident class were calculated. Twenty-one residents participated. The overall average test score and the mean test score of each resident class was less than 70%. Second-year residents had the highest mean test scores, although there was no significant difference between the classes of residents (p =.745) or relationship between the residents' PICU experiences and their exam scores (p =.766). There was no significant difference between residents' levels of training and whether they double-checked their calculations (p =.633) or considered each patient's weight relative to the dose prescribed (p =.869). Seven residents committed tenfold dosing errors, and one resident committed a 1,000-fold dosing error. Pediatrics residents need to receive additional education in performing the calculations needed to prescribe medications. In addition, residents should be required to demonstrate these necessary mathematical skills before they are allowed to prescribe medications.

  1. Internal Dose from Food and Drink Ingestion in the Early Phase after the Accident

    NASA Astrophysics Data System (ADS)

    Kawai, Masaki; Yoshizawa, Nobuaki; Hirakawa, Sachiko; Murakami, Kana; Takizawa, Mari; Sato, Osamu; Takagi, Shunji; Miyatake, Hirokazu; Takahashi, Tomoyuki; Suzuki, Gen

    2017-09-01

    Activity concentrations in food and drink, represented by water and vegetables, have been monitored continuously since the Fukushima Daiichi Nuclear Power Plant accident, with a focus on radioactive cesium. On the other hand, iodine-131 was not measured systematically in the early phase after the accident. The activity concentrations of iodine-131 in food and drink are important to estimate internal exposure due to ingestion pathway. When the internal dose from ingestion in the evacuation areas is estimated, water is considered as the main ingestion pathway. In this study, we estimated the values of activity concentrations in water in the early phase after the accident, using a compartment model as an estimation method. The model uses measurement values of activity concentration and deposition rate of iodine-131 onto the ground, which is calculated from an atmospheric dispersion simulation. The model considers how drinking water would be affected by radionuclides deposited into water. We estimated the activity concentrations of water on Kawamata town and Minamisouma city during March of 2011 and the committed effective doses were 0.08 mSv and 0.06 mSv. We calculated the transfer parameters in the model for estimating the activity concentrations in the areas with a small amount of measurement data. In addition, we estimated the committed effective doses from vegetables using atmospheric dispersion simulation and FARMLAND model in case of eating certain vegetables as option information.

  2. 40 CFR 191.12 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... metric system which has been established by the International Bureau of Weights and Measures and is...) monitoring parameters related to disposal system performance. Annual committed effective dose means the... radioactive wastes in a disposal system; and (2) the subsurface underlying such a surface location. Disposal...

  3. 40 CFR 191.12 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... metric system which has been established by the International Bureau of Weights and Measures and is...) monitoring parameters related to disposal system performance. Annual committed effective dose means the... radioactive wastes in a disposal system; and (2) the subsurface underlying such a surface location. Disposal...

  4. 40 CFR 191.12 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... metric system which has been established by the International Bureau of Weights and Measures and is...) monitoring parameters related to disposal system performance. Annual committed effective dose means the... radioactive wastes in a disposal system; and (2) the subsurface underlying such a surface location. Disposal...

  5. [A study of work values, professional commitment, turnover intention and related factors among clinical nurses].

    PubMed

    Wang, Kuei-Ying; Chou, Chuan-Chiang; Huang, Jui-Lan

    2010-02-01

    The high rate of turnover in nursing positions is a global problem. There have been few studies done addressing the relationship between work values and nurse turnover intention. The purpose of this study was to explore the relationship between work values, professional commitment and turnover intention among clinical nurses. A cross-sectional survey was conducted between February 1st to March 10th, 2008 on a convenience sample of nurses, all of whom had at least a half year of work experience at one of four teaching hospitals in Taiwan. A total of 289 valid responses were received, with a response rate of 96.3%. Major findings included: (1) Nurses who were older, had more years of school, had worked more years, held specific job duties, earned a higher salary, held Buddhist beliefs, or were married with two or more children presented higher work values and professional commitment and lower turnover intention; (2) As a group, total work values and professional commitment scores corresponded negatively with turnover intention scores; (3) Significant factors affecting turnover intent in clinical nurses included professional commitment, institution characteristics, Buddhist beliefs and salary. These four variables accounted for 52.2% of the variation in turnover intention. This study indicated that nurses with higher work values and professional commitment tend to exhibit less turnover intention. It is highly recommended to develop strategies to bolster the teaching of altruistic values and professional commitment in nursing education in order to reduce turnover intent. Also, further studies on the influence of religious beliefs and organizational attributes on nurse turnover intentions are also suggested.

  6. Predictors of organizational commitment among staff in assisted living.

    PubMed

    Sikorska-Simmons, Elzbieta

    2005-04-01

    This study examines the role of organizational culture, job satisfaction, and sociodemographic characteristics as predictors of organizational commitment among staff in assisted living. It is particularly important to examine organizational commitment, because of its close links to staff turnover. Data were collected from 317 staff members in 61 facilities, using self-administered questionnaires. The facilities were selected from licensed assisted living programs and were stratified into small, traditional, and new-model homes. Staff questionnaires were distributed by a researcher during 1-day visits to each facility. Organizational commitment was measured by the extent of staff identification, involvement, and loyalty to the organization. Organizational culture, job satisfaction, and education were strong predictors of commitment, together explaining 58% of the total variance in the dependent variable. Higher levels of organizational commitment were associated with more favorable staff perceptions of organizational culture and greater job satisfaction. In addition, more educated staff members tended to report higher levels of organizational commitment. Other than education, sociodemographic characteristics failed to account for a significant amount of variance in organizational commitment. Because job satisfaction and organizational culture were strong predictors of commitment, interventions aimed at increasing job satisfaction and creating an organizational culture that values and respects staff members could be most effective in producing higher levels of organizational commitment.

  7. Impact of the new nuclear decay data of ICRP publication 107 on inhalation dose coefficients for workers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manabe, K.; Endo, Akira; Eckerman, Keith F

    2010-03-01

    The impact a revision of nuclear decay data had on dose coefficients was studied using data newly published in ICRP Publication 107 (ICRP 107) and existing data from ICRP Publication 38 (ICRP 38). Committed effective dose coefficients for occupational inhalation of radionuclides were calculated using two sets of decay data with the dose and risk calculation software DCAL for 90 elements, 774 nuclides and 1572 cases. The dose coefficients based on ICRP 107 increased by over 10 % compared with those based on ICRP 38 in 98 cases, and decreased by over 10 % in 54 cases. It was foundmore » that the differences in dose coefficients mainly originated from changes in the radiation energy emitted per nuclear transformation. In addition, revisions of the half-lives, radiation types and decay modes also resulted in changes in the dose coefficients.« less

  8. Intracellular Retention of ABL Kinase Inhibitors Determines Commitment to Apoptosis in CML Cells

    PubMed Central

    Dziadosz, Marek; Schnöder, Tina; Heidel, Florian; Schemionek, Mirle; Melo, Junia V.; Kindler, Thomas; Müller-Tidow, Carsten; Koschmieder, Steffen; Fischer, Thomas

    2012-01-01

    Clinical development of imatinib in CML established continuous target inhibition as a paradigm for successful tyrosine kinase inhibitor (TKI) therapy. However, recent reports suggested that transient potent target inhibition of BCR-ABL by high-dose TKI (HD-TKI) pulse-exposure is sufficient to irreversibly commit cells to apoptosis. Here, we report a novel mechanism of prolonged intracellular TKI activity upon HD-TKI pulse-exposure (imatinib, dasatinib) in BCR-ABL-positive cells. Comprehensive mechanistic exploration revealed dramatic intracellular accumulation of TKIs which closely correlated with induction of apoptosis. Cells were rescued from apoptosis upon HD-TKI pulse either by repetitive drug wash-out or by overexpression of ABC-family drug transporters. Inhibition of ABCB1 restored sensitivity to HD-TKI pulse-exposure. Thus, our data provide evidence that intracellular drug retention crucially determines biological activity of imatinib and dasatinib. These studies may refine our current thinking on critical requirements of TKI dose and duration of target inhibition for biological activity of TKIs. PMID:22815843

  9. Cesium-137 body burdens in Norwegian Lapps, 1965-1983.

    PubMed

    Westerlund, E A; Berthelsen, T; Berteig, L

    1987-02-01

    Results of measurements of the whole-body contents of 137Cs during the period 1965-1983 in Lapps from the Kautokeino area in Norway are reported with measurements of 137Cs in reindeer meat during the period 1966-1983. By using available data on 137Cs in precipitation for the period 1950-1980, transfer coefficients from 137Cs in precipitation to reindeer meat have been assessed. A correlation between the 137Cs content in reindeer meat and the 137Cs content in Lapp reindeer breeders has been established. The average whole-body committed dose equivalent, H50, to the reindeer breeders from internally deposited 137Cs from intakes up to year 2000 was assessed to 13 mSv with a peak value of 30 mSv. In comparison, the corresponding committed dose equivalent to the Norwegian population from internally deposited 137Cs has been estimated to be about 1 mSv. The higher intake of 137Cs by reindeer breeders is due to the lichen-reindeer-man exposure pathway.

  10. Capstone Depleted Uranium Aerosol Biokinetics, Concentrations, and Doses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guilmette, Raymond A.; Miller, Guthrie; Parkhurst, MaryAnn

    2009-02-26

    One of the principal goals of the Capstone Depleted Uranium (DU) Aerosol Study was to quantify and characterize DU aerosols generated inside armored vehicles by perforation with a DU penetrator. This study consequently produced a database in which the DU aerosol source terms were specified both physically and chemically for a variety of penetrator-impact geometries and conditions. These source terms were used to calculate radiation doses and uranium concentrations for various scenarios as part of the Capstone DU Human Health Risk Assessment (HHRA). This paper describes the scenario-related biokinetics of uranium, and summarizes intakes, chemical concentrations to the organs, andmore » E(50) and HT(50) for organs and tissues based on exposure scenarios for personnel in vehicles at the time of perforation as well as for first responders. For a given exposure scenario (duration time and breathing rates), the range of DU intakes among the target vehicles and shots was not large, about a factor of 10, with the lowest being from a ventilated operational Abrams tank and the highest being for an unventilated Abrams with DU penetrator perforating DU armor. The ranges of committed effective doses were more scenario-dependent than were intakes. For example, the largest range, a factor of 20, was shown for scenario A, a 1-min exposure, whereas, the range was only a factor of two for the first-responder scenario (E). In general, the committed effective doses were found to be in the tens of mSv. The risks ascribed to these doses are discussed separately.« less

  11. Head office commitment to quality-related event reporting in community pharmacy

    PubMed Central

    Scobie, Andrea C.; Boyle, Todd A.; MacKinnon, Neil J.; Mahaffey, Thomas

    2012-01-01

    Background: This research explores how perceptions of head office commitment to quality-related event (QRE) reporting differ between pharmacy staff type and between pharmacies with high and low QRE reporting and learning performance. QREs include known, alleged or suspected medication errors that reach the patient as well as medication errors that are intercepted prior to dispensing. Methods: A survey questionnaire was mailed in the spring of 2010 to 427 pharmacy managers, pharmacists and pharmacy technicians in Nova Scotia. Nonparametric statistics were used to determine differences based on pharmacy staff type and pharmacy performance. Content analysis was used to analyze the responses to open-ended survey questions. Results: A total of 210 surveys were returned, for a response rate of 49.2%. However, the current study used only the subgroup of pharmacy staff who self-reported working at a chain pharmacy, for a total of 124 usable questionnaires. The results showed that community pharmacies viewed head office commitment to QRE reporting as an area to improve. In general, high-performing pharmacies ranked head office commitment higher than low-performing pharmacies. Discussion: One possible reason why high-performing pharmacies ranked the variables higher may be that increased levels of head office support for QRE processes have led these pharmacies to adopt and commit to QRE processes and thus increase their performance. Conclusion: Demonstrated commitment to QRE reporting, ongoing encouragement and targeted messages to staff could be important steps for head office to increase QRE reporting and learning in community pharmacies. PMID:23509532

  12. Head office commitment to quality-related event reporting in community pharmacy.

    PubMed

    Scobie, Andrea C; Boyle, Todd A; Mackinnon, Neil J; Mahaffey, Thomas

    2012-05-01

    This research explores how perceptions of head office commitment to quality-related event (QRE) reporting differ between pharmacy staff type and between pharmacies with high and low QRE reporting and learning performance. QREs include known, alleged or suspected medication errors that reach the patient as well as medication errors that are intercepted prior to dispensing. A survey questionnaire was mailed in the spring of 2010 to 427 pharmacy managers, pharmacists and pharmacy technicians in Nova Scotia. Nonparametric statistics were used to determine differences based on pharmacy staff type and pharmacy performance. Content analysis was used to analyze the responses to open-ended survey questions. A total of 210 surveys were returned, for a response rate of 49.2%. However, the current study used only the subgroup of pharmacy staff who self-reported working at a chain pharmacy, for a total of 124 usable questionnaires. The results showed that community pharmacies viewed head office commitment to QRE reporting as an area to improve. In general, high-performing pharmacies ranked head office commitment higher than low-performing pharmacies. One possible reason why high-performing pharmacies ranked the variables higher may be that increased levels of head office support for QRE processes have led these pharmacies to adopt and commit to QRE processes and thus increase their performance. Demonstrated commitment to QRE reporting, ongoing encouragement and targeted messages to staff could be important steps for head office to increase QRE reporting and learning in community pharmacies.

  13. 75 FR 16825 - Notice of Modifications to U.S. Commitments Under the World Trade Organization Government...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-02

    ... hearing- or speech-impairments may access this number through TTY by calling the toll-free Federal... construction project, and the total construction project has an estimated value of more than $7,804,000....S. Commitments Under the World Trade Organization Government Procurement Agreement To Implement...

  14. Relationships between Teacher Organizational Commitment, Psychological Hardiness and Some Demographic Variables in Turkish Primary Schools

    ERIC Educational Resources Information Center

    Sezgin, Ferudun

    2009-01-01

    Purpose: The purpose of this paper is to examine the relationships between teachers' organizational commitment perceptions and both their psychological hardiness and some demographic variables in a sample of Turkish primary schools. Design/methodology/approach: A total of 405 randomly selected teachers working at primary schools in Ankara…

  15. Exploring the Relationship Between Professional Commitment and Job Satisfaction Among Nurses.

    PubMed

    Hsu, Hsiu-Chin; Wang, Pao-Yu; Lin, Li-Hui; Shih, Whei-Mei; Lin, Mei-Hsiang

    2015-09-01

    This cross-sectional study explored the relationship between professional commitment and job satisfaction among nurses. A total of 132 registered nurses were recruited from a hospital in northern Taiwan. A self-reported structured questionnaire was used to collect data. Findings revealed significant differences among nurses in willingness to make an effort and their marital status, appraisal in continuing their careers, job level, and goals and values related to working shifts. Significant differences were found between inner satisfaction and work sector and marital status. Nurses' professional commitment was strongly related to job satisfaction; aspects of professional commitment explained 32% of the variance in job satisfaction. Study results may inform health care institutions about the importance of nurses' job satisfaction and professional commitment so hospital administration can improve these aspects of organizational environment. © 2015 The Author(s).

  16. Role of Organizational Climate in Organizational Commitment: The Case of Teaching Hospitals.

    PubMed

    Bahrami, Mohammad Amin; Barati, Omid; Ghoroghchian, Malake-Sadat; Montazer-Alfaraj, Razieh; Ranjbar Ezzatabadi, Mohammad

    2016-04-01

    The commitment of employees is affected by several factors, including factors related to the organizational climate. The aim of this study was to investigate the relationship between organizational commitment of nurses and the organizational climate in hospital settings. A cross-sectional study was conducted in 2014 at two teaching hospitals in Yazd, Iran. A total of 90 nurses in these hospitals participated. We used stratified random sampling of the nursing population. The required data were gathered using two valid questionnaires: Allen and Meyer's organizational commitment standard questionnaire and Halpin and Croft's Organizational Climate Description Questionnaire. Data analysis was done through SPSS 20 statistical software (IBM Corp., Armonk, NY, USA). We used descriptive statistics and Pearson's correlation coefficient for the data analysis. The findings indicated a positive and significant correlation between organizational commitment and organizational climate (r = 0.269, p = 0.01). There is also a significant positive relationship between avoidance of organizational climate and affective commitment (r = 0.208, p = 0.049) and between focus on production and normative and continuance commitment (r = 0.308, p = 0.003). Improving the organizational climate could be a valuable strategy for improving organizational commitment.

  17. Salmonella Enteritidis Deposition inside Eggs after Experimental Infection of Laying Hens with Different Oral Doses

    USDA-ARS?s Scientific Manuscript database

    The continuing attribution of human Salmonella Enteritidis infections to internally contaminated eggs has necessitated the commitment of substantial public and private resources to risk reduction and testing programs for commercial laying flocks. Cost-effective risk reduction requires a detailed und...

  18. Athletic trainers' barriers to maintaining professional commitment in the collegiate setting.

    PubMed

    Mazerolle, Stephanie M; Eason, Christianne M; Pitney, William A

    2015-05-01

    Professional commitment simply describes one's obligation to his or her work. For athletic trainers (ATs), the demanding work environment and job expectations may affect their characterization of professional commitment. Our breadth of knowledge regarding professional commitment within athletic training is narrow. To evaluate the professional commitment of ATs in the collegiate setting. Qualitative study. Collegiate. Thirty-three Board of Certification-certified ATs employed in the collegiate setting (National Collegiate Athletic Association Division I = 11, Division II = 9, Division III = 13) with an average of 10 ± 8 years of clinical experience volunteered. Data saturation guided the total number of participants. Online journaling via QuestionPro was completed by all participants. Multiple-analyst triangulation and peer review were conducted for data credibility. Analysis followed a general inductive method. Four themes speak to the factors that negatively affect ATs' professional enthusiasm and commitment: (1) life stage, (2) work overload, (3) organizational climate, and (4) human resources. The latter 3 speak to the effect the workplace can have on ATs' professional commitment, and the first speaks to the effect outside responsibilities can have. Our results suggest that several of the factors that negatively influence the professional commitment of collegiate ATs are modifiable organizational components. Developing resiliency strategies at the individual and organizational levels may help to facilitate improved professional commitment for the AT.

  19. The impact of nurses' spiritual health on their attitudes toward spiritual care, professional commitment, and caring.

    PubMed

    Chiang, Yi-Chien; Lee, Hsiang-Chun; Chu, Tsung-Lan; Han, Chin-Yen; Hsiao, Ya-Chu

    2016-01-01

    The personal spiritual health of nurses may play an important role in improving their attitudes toward spiritual care and their professional commitment and caring capabilities. The purpose of this study was to explore the impact of nurses' personal spiritual health on their attitudes toward spiritual care, professional commitment, and caring. A total of 619 clinical nurses were included in this cross-sectional survey. The measurements included the spiritual health scale-short form, the spiritual care attitude scale, the nurses' professional commitment scale, and the caring behaviors scale. Structural equation modeling was used to establish associations between the main research variables. The hypothetical model provided a good fit with the data. Nurses' spiritual health had a positive effect on nurses' professional commitment and caring. Nurses' attitudes toward spiritual care could therefore mediate their personal spiritual health, professional commitment, and caring. The findings indicated that nurses' personal spiritual health is an important value and belief system and can influence their attitudes toward spiritual care, professional commitment, and caring. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. TGFβ1-Induced Differentiation of Human Bone Marrow-Derived MSCs Is Mediated by Changes to the Actin Cytoskeleton.

    PubMed

    Elsafadi, Mona; Manikandan, Muthurangan; Almalki, Sami; Mobarak, Mohammad; Atteya, Muhammad; Iqbal, Zafar; Hashmi, Jamil Amjad; Shaheen, Sameerah; Alajez, Nehad; Alfayez, Musaad; Kassem, Moustapha; Dawud, Raed Abu; Mahmood, Amer

    2018-01-01

    TGF β is a potent regulator of several biological functions in many cell types, but its role in the differentiation of human bone marrow-derived skeletal stem cells (hMSCs) is currently poorly understood. In the present study, we demonstrate that a single dose of TGF β 1 prior to induction of osteogenic or adipogenic differentiation results in increased mineralized matrix or increased numbers of lipid-filled mature adipocytes, respectively. To identify the mechanisms underlying this TGF β -mediated enhancement of lineage commitment, we compared the gene expression profiles of TGF β 1-treated hMSC cultures using DNA microarrays. In total, 1932 genes were upregulated, and 1298 genes were downregulated. Bioinformatics analysis revealed that TGF β l treatment was associated with an enrichment of genes in the skeletal and extracellular matrix categories and the regulation of the actin cytoskeleton. To investigate further, we examined the actin cytoskeleton following treatment with TGF β 1 and/or cytochalasin D. Interestingly, cytochalasin D treatment of hMSCs enhanced adipogenic differentiation but inhibited osteogenic differentiation. Global gene expression profiling revealed a significant enrichment of pathways related to osteogenesis and adipogenesis and of genes regulated by both TGF β 1 and cytochalasin D. Our study demonstrates that TGF β 1 enhances hMSC commitment to either the osteogenic or adipogenic lineages by reorganizing the actin cytoskeleton.

  1. 2004 Environmental Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Althouse, P E; Bertoldo, N A; Brown, R A

    2005-09-28

    The Lawrence Livermore National Laboratory (LLNL) annual Environmental Report, prepared for the Department of Energy (DOE) and made available to the public, presents summary environmental data that characterizes site environmental management performance, summarizes environmental occurrences and responses reported during the calendar year, confirms compliance with environmental standards and requirements, and highlights significant programs and efforts. By explaining the results of effluent and environmental monitoring, mentioning environmental performance indicators and performance measure programs, and assessing the impact of Laboratory operations on the environment and the public, the report also demonstrates LLNL's continuing commitment to minimize any potentially adverse impact of itsmore » operations. The combination of environmental and effluent monitoring, source characterization, and dose assessment showed that radiological doses to the public caused by LLNL operations in 2004 were less than 0.26% of regulatory standards and more than 11,000 times smaller than dose from natural background. Analytical results and evaluations generally showed continuing low levels of most contaminants; remediation efforts further reduced the concentrations of contaminants of concern in groundwater and soil vapor. In addition, LLNL's extensive environmental compliance activities related to water, air, endangered species, waste, wastewater, and waste reduction controlled or reduced LLNL's effects on the environment. LLNL's environmental program clearly demonstrates a commitment to protecting the environment from operational impacts.« less

  2. 10 CFR 835.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Reasonably Achievable,” which is the approach to radiation protection to manage and control exposures (both... (Sv)) (1 rem = 0.01 Sv) or a committed equivalent dose of 50 rems (0.5 Sv) to any individual organ or... radiological control. Background means radiation from: (1) Naturally occurring radioactive materials which have...

  3. 10 CFR 835.2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Reasonably Achievable,” which is the approach to radiation protection to manage and control exposures (both... (Sv)) (1 rem = 0.01 Sv) or a committed equivalent dose of 50 rems (0.5 Sv) to any individual organ or... radiological control. Background means radiation from: (1) Naturally occurring radioactive materials which have...

  4. 10 CFR 835.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Reasonably Achievable,” which is the approach to radiation protection to manage and control exposures (both... (Sv)) (1 rem = 0.01 Sv) or a committed equivalent dose of 50 rems (0.5 Sv) to any individual organ or... radiological control. Background means radiation from: (1) Naturally occurring radioactive materials which have...

  5. 10 CFR 835.2 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Reasonably Achievable,” which is the approach to radiation protection to manage and control exposures (both... (Sv)) (1 rem = 0.01 Sv) or a committed equivalent dose of 50 rems (0.5 Sv) to any individual organ or... radiological control. Background means radiation from: (1) Naturally occurring radioactive materials which have...

  6. 10 CFR 835.2 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Reasonably Achievable,” which is the approach to radiation protection to manage and control exposures (both... (Sv)) (1 rem = 0.01 Sv) or a committed equivalent dose of 50 rems (0.5 Sv) to any individual organ or... radiological control. Background means radiation from: (1) Naturally occurring radioactive materials which have...

  7. Detecting Salmonella Enteritidis in Laying Hens and Eggs after Experimental Infection at Different Oral Dose Levels

    USDA-ARS?s Scientific Manuscript database

    The attribution of human illness to eggs contaminated with Salmonella Enteritidis has led to substantial commitments of resources (by both government and industry) to risk reduction and testing programs in egg-laying flocks. Cost-effective application of testing requires a thorough understanding of ...

  8. Salmonella Enteritidis deposition in eggs after experimental infection of laying hens with different oral doses

    USDA-ARS?s Scientific Manuscript database

    The continuing attribution of human Salmonella Enteritidis (SE) infections to internally contaminated eggs has necessitated the commitment of substantial public and private resources to SE testing and control programs in commercial laying flocks. Cost-effective risk reduction requires a detailed and...

  9. Job and career influences on the career commitment of health care executives: the mediating effect of job satisfaction.

    PubMed

    Myrtle, Robert; Chen, Duan-Rung; Liu, Caroline; Fahey, Daniel

    2011-01-01

    While there is considerable evidence supporting the relationship between job satisfaction and organizational commitment, the relationship between the antecedents of job satisfaction, organizational commitment and career commitment are not clearly understood. This study seeks to clarify whether these antecedents have an effect independent of job satisfaction on career commitment or whether these antecedents are mediated by job satisfaction. In total, 2,799 questionnaires were mailed out to members of the American College of Healthcare Executives (ACHE). The responses received were 643 (22.9 percent) and after eliminating retirees or students, a sample of 456 respondents currently employed in the health care industry was obtained. Path analysis was conducted to test the hypothetical relationships between work situation, career experiences and career commitment. It was found that job satisfaction mediated the influences of job tenure and career pattern on career commitment. Job satisfaction partially mediated the influences of perceived job security and one's satisfaction with career on career commitment. Both of these measures had a direct influence on career commitment. Career experience such as sector change was also positively associated with career commitment. While the research offers some insights into the factors affecting the career commitment of health care executives, the sample was limited to respondents who were members of the American College of Healthcare Executives, and thus may not represent the views of all managers in the health care sector. To retain high-valued health care workers it is important that an organization has a work environment that enhances their commitment to their occupation as well as their careers. This study clarifies the influence of job satisfaction on the career commitment of health care managers during a very dynamic period.

  10. The Investigation of STEM Self-Efficacy and Professional Commitment to Engineering among Female High School Students

    ERIC Educational Resources Information Center

    Liu, Yi-hui; Lou, Shi-jer; Shih, Ru-chu

    2014-01-01

    This study employed social cognitive theory and social cognitive career theory (SCCT) as foundations to explore the influence of high school students' beliefs about female gender roles and female engineer role models on science, technology, engineering, and mathematics (STEM) self-efficacy and professional commitment to engineering. A total of 88…

  11. The Association between the Nature of the Goal Committed to and Quitting Smoking

    ERIC Educational Resources Information Center

    Borland, Ron; Li, Lin; Balmford, James

    2017-01-01

    Commitments to goals are theorized to affect behavior change outcomes, but competing theories argue for hard to achieve goals and strategic sub-goals as optimum strategies for success. This study aimed to explore whether the nature of the goal affects smoking cessation outcomes. A total of 1043 participants in a randomized controlled trial of…

  12. University Mid-Level Administrators: Comparisons between Men and Women on Work Experience, Commitment, and Job Satisfaction.

    ERIC Educational Resources Information Center

    Austin, Ann E.

    Male and female mid-level administrators at a large research university were compared on personal and demographic variables; perceptions of opportunities and job/organizational characteristics; job satisfaction; and degree of commitment to job, institution, and career. A total of 192 male and 38 female administrators participated. While males and…

  13. Why Does an Adolescent Commit a Crime?

    ERIC Educational Resources Information Center

    Ziiadova, D.

    2004-01-01

    In the past few years, Russian adolescents have become a criminally active category of the population. A substantial portion of the contingents of participants in crime consists of students in general education schools. In 2000, their proportion added up to 27 percent of all crimes committed by minors. A study of the structure of the total file of…

  14. The Effects of Secondary School Administrators' Servant Leadership Behaviors on Teachers' Organizational Commitment

    ERIC Educational Resources Information Center

    Türkmen, Fatma; Gül, Ibrahim

    2017-01-01

    The purpose of this research is to examine the effects of secondary school administrators' servant leadership behavior on teachers' organizational commitment. This research was designed based on the relational screening model. The population of the study consists of 753 secondary school teachers. 438 teachers from the total population participated…

  15. Workplace Learning, Job Satisfaction, and Organizational Commitment in Small to Midsize Companies in Taiwan

    ERIC Educational Resources Information Center

    Chiang, Ti-Lin; Wang, Jia

    2008-01-01

    This quantitative study explored the relationships among workplace learning, job satisfaction, and organizational commitment (OC) in the context of small to midsize information technology companies in Taiwan. Twenty-six companies participated in the study, and a total of 206 valid surveys were collected and analyzed out of 450 that were…

  16. Emotional intelligence, performance, and retention in clinical staff nurses.

    PubMed

    Codier, Estelle; Kamikawa, Cindy; Kooker, Barbara M; Shoultz, Jan

    2009-01-01

    Emotional intelligence has been correlated with performance, retention, and organizational commitment in professions other than nursing. A 2006 pilot study provided the first evidence of a correlation between emotional intelligence and performance in clinical staff nurses. A follow-up study was completed, the purpose of which was to explore emotional intelligence, performance level, organizational commitment, and retention. A convenience sample of 350 nurses in a large medical center in urban Hawaii participated in this study. This article reports the findings pertaining to the subset of 193 clinical staff nurses who responded. The Mayer-Salovey-Caruso Emotional Intelligence Test instrument was used to measure emotional intelligence abilities. Performance was defined as ranking on a clinical ladder. Commitment was scored on a Likert scale. The following variables measured retention: total years in nursing, years in current job, total years anticipated in current job, and total anticipated career length. Emotional intelligence scores in clinical staff nurses correlated positively with both performance level and retention variables. Clinical staff nurses with higher emotional intelligence scores demonstrated higher performance, had longer careers, and greater job retention.

  17. Athletic Trainers' Barriers to Maintaining Professional Commitment in the Collegiate Setting

    PubMed Central

    Mazerolle, Stephanie M.; Eason, Christianne M.; Pitney, William A.

    2015-01-01

    Context: Professional commitment simply describes one's obligation to his or her work. For athletic trainers (ATs), the demanding work environment and job expectations may affect their characterization of professional commitment. Our breadth of knowledge regarding professional commitment within athletic training is narrow. Objective: To evaluate the professional commitment of ATs in the collegiate setting. Design: Qualitative study. Setting: Collegiate. Patients or Other Participants: Thirty-three Board of Certification-certified ATs employed in the collegiate setting (National Collegiate Athletic Association Division I = 11, Division II = 9, Division III = 13) with an average of 10 ± 8 years of clinical experience volunteered. Data saturation guided the total number of participants. Data Collection and Analysis: Online journaling via QuestionPro was completed by all participants. Multiple-analyst triangulation and peer review were conducted for data credibility. Analysis followed a general inductive method. Results: Four themes speak to the factors that negatively affect ATs' professional enthusiasm and commitment: (1) life stage, (2) work overload, (3) organizational climate, and (4) human resources. The latter 3 speak to the effect the workplace can have on ATs' professional commitment, and the first speaks to the effect outside responsibilities can have. Conclusions: Our results suggest that several of the factors that negatively influence the professional commitment of collegiate ATs are modifiable organizational components. Developing resiliency strategies at the individual and organizational levels may help to facilitate improved professional commitment for the AT. PMID:25761133

  18. Predictors of career commitment and job performance of Jordanian nurses.

    PubMed

    Mrayyan, Majd T; Al-Faouri, Ibrahim

    2008-04-01

    Few studies focused on nurses' career commitment and nurses' job performance. This research aimed at studying variables of nurses' career commitment and job performance, and assessing the relationship between the two concepts as well as their predictors. A survey was used to collect data from a convenient sample of 640 Registered Nurses employed in 24 hospitals. Nurses 'agreed' to be committed to their careers and they were performing their jobs 'well'. As a part of career commitment, nurses were willing to be involved, in their own time, in projects that would benefit patient care. The highest and lowest means of nurses' job performance were reported for the following aspects: leadership, critical care, teaching/collaboration, planning/evaluation, interpersonal relations/communications and professional development. Correlating of total scores of nurses' career commitment and job performance revealed the presence of a significant and positive relationship between the two concepts. Stepwise regression models revealed that the explained variance in nurses' career commitment was 23.9% and that in nurses' job performance was 29.9%. Nurse managers should promote nursing as a career and they should develop and implement various strategies to increase nurses' career commitment and nurses' job performance. These strategies should focus on nurse retention, staff development and quality of care. Nurses' career commitment and job performance are inter-related complex concepts that require further studies to understand, promote and maintain these positive factors in work environments.

  19. Acculturation, collectivist orientation and organisational commitment among Asian nurses working in the US healthcare system.

    PubMed

    Liou, Shwu-Ru; Tsai, Hsiu-Min; Cheng, Ching-Yu

    2013-05-01

    To examine the relationships between acculturation, collectivist orientation and organisational commitment among Asian nurses in US hospitals. Few studies have explored these three variables together in the same study and examined their statuses and mutual relationship among Asian nurses in Western hospitals. The study was a cross-sectional design using snowball sampling. A total of 195 Asian nurses participated. The collectivist orientation scale, organisational commitment questionnaire and acculturation factors were used to collect data. Pearson correlation, anova and regression were used to analyse the data. Most participants were female Filipinos with a mean age of 39.92 and a bachelor's degree and stayed in the USA for 13.35 years. They used and preferred to use both their mother language and English, identified themselves as Oriental or Asian and culturally, viewed themselves as very or mostly Asian. Participants scored high on collectivism and commitment. Collectivism was significantly correlated with commitment but did not mediate acculturation factors and commitment. To increase Asian nurses' commitment, it is important that administrators understand their cultural values and provide them with a cultural competent and sensitive environment. Healthcare administrators can increase Asian nurses' commitment through understanding their needs and attitudes toward their job and organisation. © 2012 Blackwell Publishing Ltd.

  20. Role of Organizational Climate in Organizational Commitment: The Case of Teaching Hospitals

    PubMed Central

    Bahrami, Mohammad Amin; Barati, Omid; Ghoroghchian, Malake-sadat; Montazer-alfaraj, Razieh; Ranjbar Ezzatabadi, Mohammad

    2015-01-01

    Objective The commitment of employees is affected by several factors, including factors related to the organizational climate. The aim of this study was to investigate the relationship between organizational commitment of nurses and the organizational climate in hospital settings. Methods A cross-sectional study was conducted in 2014 at two teaching hospitals in Yazd, Iran. A total of 90 nurses in these hospitals participated. We used stratified random sampling of the nursing population. The required data were gathered using two valid questionnaires: Allen and Meyer's organizational commitment standard questionnaire and Halpin and Croft's Organizational Climate Description Questionnaire. Data analysis was done through SPSS 20 statistical software (IBM Corp., Armonk, NY, USA). We used descriptive statistics and Pearson's correlation coefficient for the data analysis. Results The findings indicated a positive and significant correlation between organizational commitment and organizational climate (r = 0.269, p = 0.01). There is also a significant positive relationship between avoidance of organizational climate and affective commitment (r = 0.208, p = 0.049) and between focus on production and normative and continuance commitment (r = 0.308, p = 0.003). Conclusion Improving the organizational climate could be a valuable strategy for improving organizational commitment. PMID:27169007

  1. The impact of psychological empowerment and organisational commitment on Chinese nurses' job satisfaction.

    PubMed

    Ouyang, Yan-Qiong; Zhou, Wen-Bin; Qu, Hui

    2015-01-01

    Research findings have shown that job satisfaction of Chinese nurses is at a low level. Limited studies have focused on the impact of psychological empowerment and organisational commitment on job satisfaction of Chinese nurses. The aim of this study is to describe job satisfaction, psychological empowerment and organisational commitment of Chinese nurses and to explore the impact of psychological empowerment and organisational commitment on the nurses' job satisfaction. A total of 726 nurses were recruited in a convenience sample from 10 tertiary hospitals. Data were collected using four questionnaires including Job Satisfaction Survey, Psychological Empowerment Scale, Organisational Commitment Scale and Demographic Questionnaire. Descriptive analysis, correlation and stepwise multiple regression were used for data analysis. Nurses' job satisfaction, psychological empowerment and organisational commitment were identified at moderate levels. Nurses' job satisfaction and psychological empowerment were significantly different in terms of age and length of service; nurse job satisfaction varied with respect to marital status. Findings further indicated that nurse job satisfaction was positively correlated with psychological empowerment and organisational commitment. Psychological empowerment, organisational commitment and marital status were significant predicting factors of nurse job satisfaction. This study provides evidence to help nursing managers and health policy-makers to develop intervention programs aimed at enhancing nurse job satisfaction and retaining nurses.

  2. The impact of psychological empowerment and organizational commitment on Chines nurses' job satisfaction.

    PubMed

    Zhou, Wen-Bin; Ouyang, Yan-Qiong; Qu, Hui

    2014-11-10

    Abstract Background: Research findings have shown that job satisfaction of Chinese nurses is at a low level. Limited studies have focused on the impact of psychological empowerment and organizational commitment on job satisfaction of Chinese nurses. Aims: The aim of this study is to describe job satisfaction, psychological empowerment and organizational commitment of Chinese nurses and to explore the impact of psychological empowerment and organizational commitment on the nurses' job satisfaction. Methods: A total of 726 nurses were recruited in a convenience sample from 10 tertiary hospitals. Data were collected using four questionnaires including Job Satisfaction Survey, Psychological Empowerment Scale, Organizational Commitment Scale and Demographic Questionnaire. Descriptive analysis, correlation and stepwise multiple regression were used for data analysis. Results: Nurses' job satisfaction, psychological empowerment, and organizational commitment were identified at moderate levels. Nurses' job satisfaction and psychological empowerment were significantly different in terms of age and length of service; nurse job satisfaction varied with respect to marital status. Findings further indicated that nurse job satisfaction was positively correlated with psychological empowerment and organizational commitment. Psychological empowerment, organizational commitment, and marital status were significant predicting factors of nurse job satisfaction. Conclusions: This study provides evidence to help nursing managers and health policy-makers to develop intervention programs aimed at enhancing nurse job satisfaction and retaining nurses.

  3. Field and bioassay indicators for internal dose intervention therapy.

    PubMed

    Carbaugh, Eugene H

    2007-05-01

    Guidance is presented that is used at the U.S. Department of Energy Hanford Site to identify the potential need for medical intervention in response to intakes of radioactivity. The guidance, based on ICRP Publication 30 models and committed effective dose equivalents of 20 mSv and 200 mSv, is expressed as numerical workplace measurements and derived first-day bioassay results for large intakes. It is used by facility radiation protection staff and on-call dosimetry support staff during the first few days following an intake.

  4. Field and Bioassay Indicators for Internal Dose Intervention Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carbaugh, Eugene H.

    2007-05-01

    Guidance is presented that is used at the U.S. Department of Energy Hanford Site to identify the potential need for medical intervention in response to intakes of radioactivity. The guidance, based on ICRP Publication 30 models and committed effective dose equivalents of 20 mSv and 200 mSv, is expressed as numerical workplace measurements and derived first-day bioassay results for large intakes. It is used by facility radiation protection staff and on-call dosimetry support staff during the first few days following an intake.

  5. Hanford Site Composite Analysis Technical Approach Description: Groundwater Pathway Dose Calculation.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morgans, D. L.; Lindberg, S. L.

    The purpose of this technical approach document (TAD) is to document the assumptions, equations, and methods used to perform the groundwater pathway radiological dose calculations for the revised Hanford Site Composite Analysis (CA). DOE M 435.1-1, states, “The composite analysis results shall be used for planning, radiation protection activities, and future use commitments to minimize the likelihood that current low-level waste disposal activities will result in the need for future corrective or remedial actions to adequately protect the public and the environment.”

  6. Relationships between professional commitment, job satisfaction, and work stress in public health nurses in Taiwan.

    PubMed

    Lu, Kuei-Yun; Chang, Liang-Chih; Wu, Hong-Lan

    2007-01-01

    The purpose of this study was to assess both direct and indirect relationships between professional commitment, job satisfaction, and work stress in public health nurses (PHNs) in Taiwan. The two major questions addressed were as follows: What were the professional commitment, job satisfaction, and work stress among PHNs? What model accurately portrays the relationships between these three independent variables? Exploration of the causal pathways among these variables revealed a fitness model. A structured, self-administered questionnaire with three scales was distributed to the subjects. A total of 258 subjects completed the questionnaire, yielding a 90% response rate. Results demonstrate a significant, direct, and positive effect of professional commitment on job satisfaction, as well as a significant inverse influence of job satisfaction on work stress. An indirect effect of professional commitment on work stress through job satisfaction was also revealed in the findings. All paths in the model were significant (P < .05). The findings of the study can help show that professional commitment plays an antecedent role to job satisfaction and work stress of nurses. This study suggests that professional commitment is an important factor related to work stress and that health care institutions should be concerned with this issue.

  7. Impact of leadership qualities on employee commitment in multi-project-based organizations

    NASA Astrophysics Data System (ADS)

    Waris, M.; Khan, A.; Ismail, I.; Adeleke, A. Q.; Panigrahi, S.

    2018-04-01

    The purpose of this study is to investigate the impact of multiple leadership qualities (MLQ) on employee commitment in multi-project-based organizsations. The dimensions of leadership qualities develop a healthy organizational environment which will lead to job satisfaction and, ultimately, job commitment. MLQ inspire the subordinates, as collective in nature, to get extra ordinary goals in the hyper competitive era. The main objective of this research is two fold ; firstly, to find out the impact of MLQ on employee job affectiveness and calculative commitment and secondly, to investigate the extent of the impact of MLQ on organizations. A total of 213 respondents were included in the study from different organizations. The data were analyzed through regression analysis by using the SPSS. The finding shows that all of the variables have a positive correlation with each other. The correlation of MLQ and employee job commitment was also found to be significant, which shows that MLQ have an impact on the organizations. Conceptual framework of the study is developed as MLQ an independent variables and its impact has been examined on the Employee Job Commitment. The results supported the hypothesis that MLQ have a positive and significant impact on employee job commitment.

  8. Predictors of nursing faculty members' organizational commitment in governmental universities.

    PubMed

    Al-Hussami, Mahmoud; Saleh, Mohammad Y N; Abdalkader, Raghed Hussein; Mahadeen, Alia I

    2011-05-01

    It is essential for all university leaders to develop and maintain an effective programme of total quality management in a climate that promotes work satisfaction and employee support. The purpose of the study was to investigate the relationship of faculty members' organizational commitment to their job satisfaction, perceived organizational support, job autonomy, workload, and pay. A quantitative study, implementing a correlational research design to determine whether relationships existed between organizational commitment and job satisfaction, perceived organizational support, job autonomy, workload and pay. Stepwise linear regression analysis was used to estimate the probability of recorded variables included significant sample characteristics namely, age, experience and other work related attributes. The outcome showed a predictive model of three predictors which were significantly related to faculty members' commitment: job satisfaction, perceived support and age.   Although the findings were positive toward organizational commitment, continued consideration should be given to the fact that faculty members remain committed as the cost associated with leaving is high. A study of this nature increases the compartment in which faculty administrators monitor the work climate, observe and identify factors that may increase or decrease job satisfaction and the work commitment. © 2011 The Authors. Journal compilation © 2011 Blackwell Publishing Ltd.

  9. Acceptance and Commitment Therapy and Cognitive-Behavioral Therapy as Treatments for Academic Procrastination: A Randomized Controlled Group Session

    ERIC Educational Resources Information Center

    Wang, Shuo; Zhou, Ya; Yu, Shi; Ran, Li-Wen; Liu, Xiang-Ping; Chen, Yu-Fei

    2017-01-01

    Objective: This study tested the efficacy of Acceptance and Commitment Therapy (ACT), compared with Cognitive-Behavioral Therapy (CBT), in alleviating academic procrastination. Method: A total of 60 (53.3% male) undergraduates suffering from academic procrastination were randomly assigned to two treatment groups (ACT and CBT) and a control group.…

  10. Doctoral Students in Music Education: Occupational Identity, Career Intent and Commitment, and Confidence for Teaching in Higher Education

    ERIC Educational Resources Information Center

    Martin, Lisa D.

    2016-01-01

    The purpose of this study was to examine music education doctoral students' shifting occupational identity beliefs, career intent and commitment, and overall confidence for teaching in higher education. A total of 124 music education doctoral students, enrolled at 29 institutions of higher education in the United States, completed a onetime,…

  11. Internal Radiation Exposure Dose in Iwaki City, Fukushima Prefecture after the Accident at Fukushima Dai-ichi Nuclear Power Plant

    PubMed Central

    Orita, Makiko; Hayashida, Naomi; Nukui, Hiroshi; Fukuda, Naoko; Kudo, Takashi; Matsuda, Naoki; Fukushima, Yoshiko; Takamura, Noboru

    2014-01-01

    As a result of the accident at the Fukushima Daiichi Nuclear Power Plant (FNPP) on 11 March 2011, a huge amount of radionuclides, including radiocesium, was released and spread over a wide area of eastern Japan. Although three years have passed since the accident, residents around the FNPP are anxious about internal radiation exposure due to radiocesium. In this study, we screened internal radiation exposure doses in Iwaki city of Fukushima prefecture, using a whole-body counter. The first screening was conducted from October 2012 to February 2013, and the second screening was conducted from May to November 2013. Study participants were employees of ALPINE and their families who underwent examination. A total of 2,839 participants (1,366 men and 1,473 women, 1–86 years old) underwent the first screening, and 2,092 (1,022 men and 1,070 women, 1–86 years old) underwent the second screening. The results showed that 99% of subjects registered below 300 Bq per body in the first screening, and all subjects registered below 300 Bq per body in the second screening. The committed effective dose ranged from 0.01–0.06 mSv in the first screening and 0.01–0.02 mSv in the second screening. Long-term follow-up studies are needed to avoid unnecessary chronic internal exposure and to reduce anxiety among the residents by communicating radiation health risks. PMID:25478794

  12. Internal radiation exposure dose in Iwaki city, Fukushima prefecture after the accident at Fukushima Dai-ichi Nuclear Power Plant.

    PubMed

    Orita, Makiko; Hayashida, Naomi; Nukui, Hiroshi; Fukuda, Naoko; Kudo, Takashi; Matsuda, Naoki; Fukushima, Yoshiko; Takamura, Noboru

    2014-01-01

    As a result of the accident at the Fukushima Daiichi Nuclear Power Plant (FNPP) on 11 March 2011, a huge amount of radionuclides, including radiocesium, was released and spread over a wide area of eastern Japan. Although three years have passed since the accident, residents around the FNPP are anxious about internal radiation exposure due to radiocesium. In this study, we screened internal radiation exposure doses in Iwaki city of Fukushima prefecture, using a whole-body counter. The first screening was conducted from October 2012 to February 2013, and the second screening was conducted from May to November 2013. Study participants were employees of ALPINE and their families who underwent examination. A total of 2,839 participants (1,366 men and 1,473 women, 1-86 years old) underwent the first screening, and 2,092 (1,022 men and 1,070 women, 1-86 years old) underwent the second screening. The results showed that 99% of subjects registered below 300 Bq per body in the first screening, and all subjects registered below 300 Bq per body in the second screening. The committed effective dose ranged from 0.01-0.06 mSv in the first screening and 0.01-0.02 mSv in the second screening. Long-term follow-up studies are needed to avoid unnecessary chronic internal exposure and to reduce anxiety among the residents by communicating radiation health risks.

  13. 10 CFR 51.75 - Draft environmental impact statement-construction permit, early site permit, or combined license.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... required. 5 The impact statement shall take account of dose commitments and health effects from fuel cycle... the site proposed. The draft environmental impact statement must not include an assessment of the... certification environmental assessment, then the draft combined license environmental impact statement shall...

  14. 10 CFR 51.75 - Draft environmental impact statement-construction permit, early site permit, or combined license.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... required. 5 The impact statement shall take account of dose commitments and health effects from fuel cycle... the site proposed. The draft environmental impact statement must not include an assessment of the... certification environmental assessment, then the draft combined license environmental impact statement shall...

  15. 10 CFR 51.75 - Draft environmental impact statement-construction permit, early site permit, or combined licesne.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... required. 5 The impact statement shall take account of dose commitments and health effects from fuel cycle... the site proposed. The draft environmental impact statement must not include an assessment of the... certification environmental assessment, then the draft combined license environmental impact statement shall...

  16. 10 CFR 51.75 - Draft environmental impact statement-construction permit, early site permit, or combined license.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... required. 5 The impact statement shall take account of dose commitments and health effects from fuel cycle... the site proposed. The draft environmental impact statement must not include an assessment of the... certification environmental assessment, then the draft combined license environmental impact statement shall...

  17. Using Acceptance and Commitment Therapy during Methadone Dose Reduction: Rationale, Treatment Description, and a Case Report

    ERIC Educational Resources Information Center

    Stotts, Angela L.; Masuda, Akihiko; Wilson, Kelly

    2009-01-01

    Many clients who undergo methadone maintenance (MM) treatment for heroin and other opiate dependence prefer abstinence from methadone. Attempts at methadone detoxification are often unsuccessful, however, due to distressing physical as well as psychological symptoms. Outcomes from an MM client who voluntarily participated in an Acceptance and…

  18. Who's Paying for the Culture Wars?

    ERIC Educational Resources Information Center

    Selden, Steven

    2005-01-01

    Conservative critiques of higher education rely on liberal doses of cash. Behind the conservative critique of U.S. higher education is a fervent commitment to ideals, to be sure--but there's also a sizable amount of conservative cash. The Bradley, Earhart, Castle Rock, and John M. Olin foundations have contributed lavishly to guidebooks aimed at…

  19. Radiocesium concentrations in wild mushrooms after the accident at the Fukushima Daiichi Nuclear Power Station: Follow-up study in Kawauchi village.

    PubMed

    Orita, Makiko; Nakashima, Kanami; Taira, Yasuyuki; Fukuda, Toshiki; Fukushima, Yoshiko; Kudo, Takashi; Endo, Yuko; Yamashita, Shunichi; Takamura, Noboru

    2017-07-27

    Since the accident at the Chernobyl Nuclear Power Plant, it has become well known that radiocesium tends to concentrate in wild mushrooms. During the recovery process after the accident at the Fukushima Daiichi Nuclear Power Station (FDNPS), it is important to perform follow-up measurements of the activity concentrations of radiocesium in mushrooms. We evaluated the activity concentrations of the detected artificial radionuclides (radiocesium) in wild mushrooms collected from Kawauchi village, which is within 30 km of the FDNPS, in 2015, four years after the accident. We found that the radiocesium was determined in 147 of 159 mushroom samples (92.4%). Based on the average mushroom consumption of Japanese citizens (6.28 kg per year), we calculated committed effective doses ranging from <0.001 to 0.6 mSv. Although committed effective doses are relatively limited, even if residents have consumed mushrooms several times, continuous monitoring of the radiocesium in mushrooms in Fukushima is needed for sustained recovery from the nuclear disaster.

  20. ASSESSING INTERNAL CONTAMINATION AFTER THE DETONATION OF A RADIOLOGICAL DISPERSION DEVICE USING A 2×2-INCH SODIUM IODIDE DETECTOR

    PubMed Central

    Dewji, S.; Hertel, N.; Ansari, A.

    2017-01-01

    The detonation of a radiological dispersion device may result in a situation where individuals inhale radioactive materials and require rapid assessment of internal contamination. The feasibility of using a 2×2-inch sodium-iodide detector to determine the committed effective dose to an individual following acute inhalation of gamma-emitting radionuclides was investigated. Experimental configurations of point sources with a polymethyl methacrylate slab phantom were used to validate Monte Carlo simulations. The validated detector model was used to simulate the responses for four detector positions on six different anthropomorphic phantoms. The nuclides examined included 241Am, 60Co, 137Cs, 131I and 192Ir. Biokinetic modelling was employed to determine the distributed activity in the body as a function of post-inhalation time. The simulation and biokinetic data were used to determine time-dependent count-rate values at optimal detector locations on the body for each radionuclide corresponding to a target committed effective dose (E50) value of 250 mSv. PMID:23436621

  1. Evaluation of the Committed Carbon Emissions and Global Warming due to the Permafrost Carbon Feedback

    NASA Astrophysics Data System (ADS)

    Elshorbany, Y. F.; Schaefer, K. M.; Jafarov, E. E.; Yumashev, D.; Hope, C.

    2017-12-01

    We quantify the increase in carbon emissions and temperature due to Permafrost Carbon feedback (PCF), defined as the amplification of anthropogenic warming due to carbon emissions from thawing permafrost (i.e., of near-surface layers to 3 m depth). We simulate the Committed PCF emissions, the cumulative total emissions from thawing permafrost by 2300 for a given global temperature increase by 2100, and investigate the resulting global warming using the Simple Biosphere/Carnegie-Ames-Stanford Approach SiBCASA model. We estimate the committed PCF emissions and warming for the Fifth Assessment Report, Representative Concentration Pathway scenarios 4.5 and 8.5 using two ensembles of five projections. For the 2 °C warming target of the global climate change treaty, committed PCF emissions increase to 24 Gt C by 2100 and 76 Gt C by 2300 and the committed PCF warming is 0.23 °C by 2300. Our calculations show that as the global temperature increase by 2100 approaches 5.8 °C, the entire stock of frozen carbon thaws out, resulting in maximum committed PCF emissions of 560 Gt C by 2300.

  2. Estimation of Radionuclide Concentrations and Average Annual Committed Effective Dose due to Ingestion for the Population in the Red River Delta, Vietnam.

    PubMed

    Van, Tran Thi; Bat, Luu Tam; Nhan, Dang Duc; Quang, Nguyen Hao; Cam, Bui Duy; Hung, Luu Viet

    2018-02-16

    Radioactivity concentrations of nuclides of the 232 Th and 238 U radioactive chains and 40 K, 90 Sr, 137 Cs, and 239+240 Pu were surveyed for raw and cooked food of the population in the Red River delta region, Vietnam, using α-, γ-spectrometry, and liquid scintillation counting techniques. The concentration of 40 K in the cooked food was the highest compared to those of other radionuclides ranging from (23 ± 5) (rice) to (347 ± 50) Bq kg -1 dw (tofu). The 210 Po concentration in the cooked food ranged from its limit of detection (LOD) of 5 mBq kg -1  dw (rice) to (4.0 ± 1.6) Bq kg -1  dw (marine bivalves). The concentrations of other nuclides of the 232 Th and 238 U chains in the food were low, ranging from LOD of 0.02 Bq kg -1  dw to (1.1 ± 0.3) Bq kg -1  dw. The activity concentrations of 90 Sr, 137 Cs, and 239+240 Pu in the food were minor compared to that of the natural radionuclides. The average annual committed effective dose to adults in the study region was estimated and it ranged from 0.24 to 0.42 mSv a -1 with an average of 0.32 mSv a -1 , out of which rice, leafy vegetable, and tofu contributed up to 16.2%, 24.4%, and 21.3%, respectively. The committed effective doses to adults due to ingestion of regular diet in the Red River delta region, Vietnam are within the range determined in other countries worldwide. This finding suggests that Vietnamese food is safe for human consumption with respect to radiation exposure.

  3. Athletic trainers' facilitators of professional commitment in the collegiate setting.

    PubMed

    Eason, Christianne M; Mazerolle, Stephanie M; Pitney, William A

    2015-05-01

    Professional responsibility, rewards and respect, and time for rejuvenation are factors supporting professional commitment for athletic trainers (ATs) in the high school setting. The inherent complexities of an occupational setting can mitigate perceptions of professional commitment. Thus far, evidence is lacking regarding professional commitment for ATs in other occupational settings. To extend the literature on professional commitment of the AT to the collegiate setting. Qualitative study. Collegiate. Thirty-three Board of Certification-certified ATs employed in the collegiate setting (National Collegiate Athletic Association Division I = 11, Division II = 9, Division III = 13) with an average of 10 ± 8 years of clinical experience volunteered. Data saturation guided the total number of participants. Online journaling via QuestionPro was used to collect data from all participants. Two strategies, multiple-analyst triangulation and peer review, were completed to satisfy data credibility. Data were evaluated using a general inductive approach. Likert-scale data revealed no differences regarding levels of professional commitment across divisions. Two themes emerged from the inductive-content analysis: (1) professional responsibility and (2) coworker support. The emergent theme of professional responsibility contained 4 subthemes: (1) dedication to advancing the athletic training profession, (2) ardor for job responsibilities, (3) dedication to the student-athlete, and (4) commitment to education. Our participants were able to better maintain their own professional commitment when they felt their coworkers were also committed to the profession. The collegiate ATs investigated in this study, regardless of division, demonstrated professional commitment propelled by their aspiration to advance the profession, as well as their dedication to student-athletes and athletic training students. Maintaining commitment was influenced by a strong sense of coworker support.

  4. Athletic Trainers' Facilitators of Professional Commitment in the Collegiate Setting

    PubMed Central

    Eason, Christianne M.; Mazerolle, Stephanie M.; Pitney, William A.

    2015-01-01

    Context: Professional responsibility, rewards and respect, and time for rejuvenation are factors supporting professional commitment for athletic trainers (ATs) in the high school setting. The inherent complexities of an occupational setting can mitigate perceptions of professional commitment. Thus far, evidence is lacking regarding professional commitment for ATs in other occupational settings. Objective: To extend the literature on professional commitment of the AT to the collegiate setting. Design: Qualitative study. Setting: Collegiate. Patients or Other Participants: Thirty-three Board of Certification-certified ATs employed in the collegiate setting (National Collegiate Athletic Association Division I = 11, Division II = 9, Division III = 13) with an average of 10 ± 8 years of clinical experience volunteered. Data saturation guided the total number of participants. Data Collection and Analysis: Online journaling via QuestionPro was used to collect data from all participants. Two strategies, multiple-analyst triangulation and peer review, were completed to satisfy data credibility. Data were evaluated using a general inductive approach. Results: Likert-scale data revealed no differences regarding levels of professional commitment across divisions. Two themes emerged from the inductive-content analysis: (1) professional responsibility and (2) coworker support. The emergent theme of professional responsibility contained 4 subthemes: (1) dedication to advancing the athletic training profession, (2) ardor for job responsibilities, (3) dedication to the student-athlete, and (4) commitment to education. Our participants were able to better maintain their own professional commitment when they felt their coworkers were also committed to the profession. Conclusions: The collegiate ATs investigated in this study, regardless of division, demonstrated professional commitment propelled by their aspiration to advance the profession, as well as their dedication to student-athletes and athletic training students. Maintaining commitment was influenced by a strong sense of coworker support. PMID:25761135

  5. Job Involvement and Organizational Commitment of Employees of Prehospital Emergency Medical System.

    PubMed

    Rahati, Alireza; Sotudeh-Arani, Hossein; Adib-Hajbaghery, Mohsen; Rostami, Majid

    2015-12-01

    Several studies are available on organizational commitment of employees in different organizations. However, the organizational commitment and job involvement of the employees in the prehospital emergency medical system (PEMS) of Iran have largely been ignored. This study aimed to investigate the organizational commitment and job involvement of the employees of PEMS and the relationship between these two issues. This cross-sectional study was conducted on 160 employees of Kashan PEMS who were selected through a census method in 2014. A 3-part instrument was used in this study, including a demographic questionnaire, the Allen and Miller's organizational commitment inventory, and the Lodahl and Kejner's job involvement inventory. We used descriptive statistics, Spearman correlation coefficient, Kruskal-Wallis, Friedman, analysis of variance, and Tukey post hoc tests to analyze the data. The mean job involvement and organizational commitment scores were 61.78 ± 10.69 and 73.89 ± 13.58, respectively. The mean scores of job involvement and organizational commitment were significantly different in subjects with different work experiences (P = 0.043 and P = 0.012, respectively). However, no significant differences were observed between the mean scores of organizational commitment and job involvement in subjects with different fields of study, different levels of interest in the profession, and various educational levels. A direct significant correlation was found between the total scores of organizational commitment and job involvement of workers in Kashan PEMS (r = 0.910, P < 0.001). This study showed that the employees in the Kashan PEMS obtained half of the score of organizational commitment and about two-thirds of the job involvement score. Therefore, the higher level managers of the emergency medical system are advised to implement some strategies to increase the employees' job involvement and organizational commitment.

  6. Work-Family Conflict, Perceived Organizational Support and Professional Commitment: A Mediation Mechanism for Chinese Project Professionals

    PubMed Central

    2018-01-01

    Projects are characterized by long working hours, complex tasks and being a kind of temporary organization. As such, work-family conflict is particularly prominent for project employees. This research examined whether and how work-family conflict affects professional commitment among Chinese project professionals. Research hypotheses were developed to explore the relationship between work-family conflict, professional commitment to the project and the mediating effects of perceived organizational support. Data were collected from 327 project managers or professionals working in construction enterprises in China; data were analyzed using structural equation modeling, applying the bootstrapping method. Results showed that there were three dimensions of work-family conflict: time-based conflict, strain-based conflict and behavior-based conflict. There were two dimensions of perceived organizational support: emotional support and instrumental support. The study also tested the negative effect of work-family conflict on professional commitment and the positive effect of perceived organizational support on professional commitment. Specifically, time-based conflict and emotional support had positive effects on professional commitment. Perceived organizational support had a total mediating effect between work-family conflict and professional commitment. The strain-based conflict dimension of work-family conflict had negative impacts on professional commitment through perceived emotional support and instrumental support. Overall, our findings extend a better understanding of work-family conflict and professional commitment in the project setting and verify the importance of social support in balancing work and family and improving employee mobility. PMID:29462860

  7. Work-Family Conflict, Perceived Organizational Support and Professional Commitment: A Mediation Mechanism for Chinese Project Professionals.

    PubMed

    Zheng, Junwei; Wu, Guangdong

    2018-02-15

    Projects are characterized by long working hours, complex tasks and being a kind of temporary organization. As such, work-family conflict is particularly prominent for project employees. This research examined whether and how work-family conflict affects professional commitment among Chinese project professionals. Research hypotheses were developed to explore the relationship between work-family conflict, professional commitment to the project and the mediating effects of perceived organizational support. Data were collected from 327 project managers or professionals working in construction enterprises in China; data were analyzed using structural equation modeling, applying the bootstrapping method. Results showed that there were three dimensions of work-family conflict: time-based conflict, strain-based conflict and behavior-based conflict. There were two dimensions of perceived organizational support: emotional support and instrumental support. The study also tested the negative effect of work-family conflict on professional commitment and the positive effect of perceived organizational support on professional commitment. Specifically, time-based conflict and emotional support had positive effects on professional commitment. Perceived organizational support had a total mediating effect between work-family conflict and professional commitment. The strain-based conflict dimension of work-family conflict had negative impacts on professional commitment through perceived emotional support and instrumental support. Overall, our findings extend a better understanding of work-family conflict and professional commitment in the project setting and verify the importance of social support in balancing work and family and improving employee mobility.

  8. The Relationship between Power Distance and Organizational Commitment in Primary Schools

    ERIC Educational Resources Information Center

    Deniz, Ayhan; Yildirim, Bilal

    2014-01-01

    The aim of this study is to determine the relationship between organizational commitment and power distance. The study has a correlational survey research model. The population of the study consists of a total of 4838 teachers working in the primary schools in the center of the city of Balikesir and in the centers of its districts in the 2012-2013…

  9. Efficacy Beliefs, Job Satisfaction, Stress and Their Influence on the Occupational Commitment of English-Medium Content Teachers in the Dominican Republic

    ERIC Educational Resources Information Center

    Barouch Gilbert, Rachel; Adesope, Olusola O.; Schroeder, Noah Lee

    2014-01-01

    The purpose of the present study was to investigate the effects of efficacy, job satisfaction, job stress and their influence on the occupational commitment of English-medium content teachers. A total of 109 practicing English-medium and Spanish-medium content teachers from the Dominican Republic volunteered to participate in the study. Findings…

  10. Interprofessional Emergency Training Leads to Changes in the Workplace.

    PubMed

    Eisenmann, Dorothea; Stroben, Fabian; Gerken, Jan D; Exadaktylos, Aristomenis K; Machner, Mareen; Hautz, Wolf E

    2018-01-01

    Preventable mistakes occur frequently and can lead to patient harm and death. The emergency department (ED) is notoriously prone to such errors, and evidence suggests that improving teamwork is a key aspect to reduce the rate of error in acute care settings. Only a few strategies are in place to train team skills and communication in interprofessional situations. Our goal was to conceptualize, implement, and evaluate a training module for students of three professions involved in emergency care. The objective was to sensitize participants to barriers for their team skills and communication across professional borders. We developed a longitudinal simulation-enhanced training format for interprofessional teams, consisting of final-year medical students, advanced trainees of emergency nursing and student paramedics. The training format consisted of several one-day training modules, which took place twice in 2016 and 2017. Each training module started with an introduction to share one's roles, professional self-concepts, common misconceptions, and communication barriers. Next, we conducted different simulated cases. Each case consisted of a prehospital section (for paramedics and medical students), a handover (everyone), and an ED section (medical students and emergency nurses). After each training module, we assessed participants' "Commitment to Change." In this questionnaire, students were anonymously asked to state up to three changes that they wished to implement as a result of the course, as well as the strength of their commitment to these changes. In total, 64 of 80 participants (80.0%) made at least one commitment to change after participating in the training modules. The total of 123 commitments was evenly distributed over four emerging categories: communication , behavior , knowledge and attitude . Roughly one third of behavior- and attitude-related commitments were directly related to interprofessional topics (e.g., "acknowledge other professions' work"), and these were equally distributed among professions. At the two-month follow-up, 32 participants (50%) provided written feedback on their original commitments: 57 of 62 (91.9%) commitments were at least partly realized at the follow-up, and only five (8.1%) commitments lacked realization entirely. A structured simulation-enhanced intervention was successful in promoting change to the practice of emergency care, while training teamwork and communication skills jointly.

  11. Ultralow Dose MSCT Imaging in Dental Implantology

    PubMed Central

    Widmann, Gerlig; Al-Ekrish, Asma'a A.

    2018-01-01

    Introduction: The Council Directive 2013/59 Euratom has a clear commitment for keeping medical radiation exposure as low as reasonably achievable and demands a regular review and use of diagnostic reference levels. Methods: In dental implantology, the range of effective doses for cone beam computed tomography (CBCT) shows a broad overlap with multislice computed tomography (MSCT). More recently, ultralow dose imaging with new generations of MSCT scanners may impart radiation doses equal to or lower than CBCT. Dose reductions in MSCT have been further facilitated by the introduction of iterative image reconstruction technology (IRT), which provides substantial noise reduction over the current standard of filtered backward projection (FBP). Aim: The aim of this article is to review the available literature on ultralow dose CT imaging and IRTs in dental implantology imaging and to summarize their influence on spatial and contrast resolution, image noise, tissue density measurements, and validity of linear measurements of the jaws. Conclusion: Application of ultralow dose MSCT with IRT technology in dental implantology offers the potential for very large dose reductions compared with standard dose imaging. Yet, evaluation of various diagnostic tasks related to dental implantology is still needed to confirm the results obtained with various IRTs and ultra-low doses so far. PMID:29492174

  12. Outcomes of an acceptance and commitment therapy-based skills training group for students with high-functioning autism spectrum disorder: a quasi-experimental pilot study.

    PubMed

    Pahnke, Johan; Lundgren, Tobias; Hursti, Timo; Hirvikoski, Tatja

    2014-11-01

    Autism spectrum disorder is characterized by social impairments and behavioural inflexibility. In this pilot study, the feasibility and outcomes of a 6-week acceptance and commitment therapy-based skills training group were evaluated in a special school setting using a quasi-experimental design (acceptance and commitment therapy/school classes as usual). A total of 28 high-functioning students with autism spectrum disorder (aged 13-21 years) were assessed using self- and teacher-ratings at pre- and post-assessment and 2-month follow-up. All participants completed the skills training, and treatment satisfaction was high. Levels of stress, hyperactivity and emotional distress were reduced in the treatment group. The acceptance and commitment therapy group also reported increased prosocial behaviour. These changes were stable or further improved at the 2-month follow-up. Larger studies are needed to further evaluate the benefits of acceptance and commitment therapy for autism spectrum disorder. © The Author(s) 2013.

  13. Financial incentives and physician commitment to guideline-recommended hypertension management.

    PubMed

    Hysong, Sylvia J; Simpson, Kate; Pietz, Kenneth; SoRelle, Richard; Broussard Smitham, Kristen; Petersen, Laura A

    2012-10-01

    To examine the impact of financial incentives on physician goal commitment to guideline-recommended hypertension care. Clinic-level cluster-randomized trial with 4 arms: individual, group, or combined incentives, and control. A total of 83 full-time primary care physicians at 12 Veterans Affairs medical centers completed web-based surveys measuring their goal commitment to guideline-recommended hypertension care every 4 months and telephone interviews at months 8 and 16. Intervention arm participants received performance-based incentives every 4 months for 5 periods. All participants received guideline education at baseline and audit and feedback every 4 months. Physician goal commitment did not vary over time or across arms. Participants reported patient nonadherence was a perceived barrier and consistent follow-up was a perceived facilitator to successful hypertension care, suggesting that providers may perceive hypertension management as more of a patient responsibility (external locus of control). Financial incentives may constitute an insufficiently strong intervention to influence goal commitment when providers attribute performance to external forces beyond their control.

  14. Relative Importance of Human Resource Practices on Affective Commitment and Turnover Intention in South Korea and United States

    PubMed Central

    Lee, Jaeyoon; Sohn, Young Woo; Kim, Minhee; Kwon, Seungwoo; Park, In-Jo

    2018-01-01

    The main purpose of this study was to investigate the impact of perceived HR practices on affective commitment and turnover intention. This study explored which HR practices were relatively more important in predicting affective commitment and turnover intention. A total of 302 employees from the United States and 317 from South Korea completed the same questionnaires for assessing the aforementioned relationships. The results illustrated that among perceived HR practices, internal mobility had the most significant association with turnover intention in both the United States and South Korea. While internal mobility was a stronger predictor of affective commitment for the United States sample, training was the most important variable for predicting affective commitment in South Korea. The second purpose of the study was to examine whether individuals’ positive affect influences the relationship between perceived HR practices and affective commitment and turnover intention. In the United States, positive affect moderated the relationship between perceived HR practices and affective commitment and turnover intention such that the relationships were stronger for individuals reporting high positive affect relative to those reporting low positive affect. However, these relationships were not significant in South Korea. We discuss the implications of these results, study limitations, and practical suggestions for future research. PMID:29867647

  15. Occupational radiation exposure experience: Paducah Gaseous Diffusion Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, R.C.

    1975-01-01

    The potential for significant uranium exposure in gaseous diffusion plants is very low. The potential for significant radiation exposure in uranium hexafluoride manufacturing is very real. Exposures can be controlled to low levels only through the cooperation and commitment of facility management and operating personnel. Exposure control can be adequately monitored by a combination of air analyses, urinalyses, and measurements of internal deposition as obtained by the IVRML. A program based on control of air-borne uranium exposure has maintained the internal dose of the Paducah Gaseous Diffusion Plant workman to less than one-half the RPG dose to the lung (15more » rem/year) and probably to less than one-fourth that dose. (auth)« less

  16. Further evaluations of the toxicity of irradiated advanced heavy water reactor fuels.

    PubMed

    Edwards, Geoffrey W R; Priest, Nicholas D

    2014-11-01

    The neutron economy and online refueling capability of heavy water moderated reactors enable them to use many different fuel types, such as low enriched uranium, plutonium mixed with uranium, or plutonium and/or U mixed with thorium, in addition to their traditional natural uranium fuel. However, the toxicity and radiological protection methods for fuels other than natural uranium are not well established. A previous paper by the current authors compared the composition and toxicity of irradiated natural uranium to that of three potential advanced heavy water fuels not containing plutonium, and this work uses the same method to compare irradiated natural uranium to three other fuels that do contain plutonium in their initial composition. All three of the new fuels are assumed to incorporate plutonium isotopes characteristic of those that would be recovered from light water reactor fuel via reprocessing. The first fuel investigated is a homogeneous thorium-plutonium fuel designed for a once-through fuel cycle without reprocessing. The second fuel is a heterogeneous thorium-plutonium-U bundle, with graded enrichments of U in different parts of a single fuel assembly. This fuel is assumed to be part of a recycling scenario in which U from previously irradiated fuel is recovered. The third fuel is one in which plutonium and Am are mixed with natural uranium. Each of these fuels, because of the presence of plutonium in the initial composition, is determined to be considerably more radiotoxic than is standard natural uranium. Canadian nuclear safety regulations require that techniques be available for the measurement of 1 mSv of committed effective dose after exposure to irradiated fuel. For natural uranium fuel, the isotope Pu is a significant contributor to the committed effective dose after exposure, and thermal ionization mass spectrometry is sensitive enough that the amount of Pu excreted in urine is sufficient to estimate internal doses, from all isotopes, as low as 1 mSv. In addition, if this method is extended so that Pu is also measured, then the combined amount of Pu and Pu is sufficiently high in the thorium-plutonium fuel that a committed effective dose of 1 mSv would be measurable. However, the fraction of Pu and Pu in the other two fuels is sufficiently low that a 1 mSv dose would remain below the detection limit using this technique. Thus new methods, such as fecal measurements of Pu (or other alpha emitters), will be required to measure exposure to these new fuels.

  17. Using Focus Groups to Modify the Workplace Affective Commitment Multidimensional Questionnaire (WACMQ) for use in Health Care.

    PubMed

    Perreira, Tyrone; Berta, Whitney

    2016-01-01

    BACKGROUND: The Workplace Affective Commitment Multidimensional Questionnaire (W ACMQ) measures affective commitment towards eight work-related targets. While this questionnaire was developed in the business sector, we believe that the multi-target conceptualization of affective commitment has applicability to complex health care contexts where providers of care, in the production and delivery of care, likely develop commitment toward a multiplicity of targets. Affective commitment is a strong predictor of extra-role workplace behavior; indispensable behaviors which enable health systems to function. OBJECTIVE: The aim of this psychometric exercise is to content validate the WACMQ questions for use in health care. METHODS: Two focus groups were conducted, consisting of nurses working in acute care and emergency hospitals in Ontario. Linguistic validation and cognitive debriefing were used. RESULTS: A total of 14 modifications to the wording of items on the original WACMQ questionnaire were made. CONCLUSIONS: This modified version of the WACMQ reflects the need for researchers in health care settings to acknowledge the complex context of health care and the attendant complexities of worker attitudes. Health care workers can experience affective commitment toward leadership (clinical or administrative), co-workers (nurses or interprofessional), patients, their profession, organization, work or tasks. Further, in some health care settings, features like union membership may have important implications when examining affective commitment or behaviors. Psychometric properties of the modified WACMQ will be established in an upcoming study that will examine the relationships between extra-role behaviors, commitment, perceived organizational support and justice within acute care and emergency departments of hospitals operating in Ontario.

  18. Supply Operations (DLA-O) Total Quality Management (TQM) Master Plan

    DTIC Science & Technology

    1989-07-01

    This document briefly outlines the DLA Directorate of Supply Operations plan to implement total quality management . It seeks to provide better...service to customers at a lower cost through continuous process improvement and commitment from everyone in the organization. Keywords: TQM (total Quality Management ), Supply operations; Continuous process improvement. (KR)

  19. Organizational commitment among general practitioners: a cross-sectional study of the role of psychosocial factors.

    PubMed

    Kuusio, Hannamaria; Heponiemi, Tarja; Sinervo, Timo; Elovainio, Marko

    2010-06-01

    To examine whether general practitioners (GP) working in primary health care have lower organizational commitment compared with physicians working in other health sectors. The authors also tested whether psychosocial factors (job demands, job control, and colleague consultation) explain these differences in commitment between GPs and other physicians. Cross-sectional postal questionnaire. Setting and participants. A postal questionnaire was sent to a random sample of physicians (n = 5000) drawn from the Finnish Association database in 2006. A total of 2841 physicians (response rate 57%) returned the questionnaire, of which 2657 (545 GPs and 2090 other physicians) fulfilled all the participant criteria. Organizational commitment was measured with two different indicators: intention to change jobs and low affective commitment. GPs were less committed to their organizations than other physicians. Work-related psychosocial factors (high job demands, low job control, and poor colleague consultation) were all significant risk factors for low organizational commitment. The evidence collected suggests that policies that reduce psychological demands, such as job demands and low control, may contribute to better organizational commitment and, thus, alleviate the shortages of physicians in primary care. Furthermore, giving GPs a stronger say in decisions concerning their work and providing them with more variety in work tasks may even improve the quality of primary care. The strategies for workplace development should focus on redesigning jobs and identifying GPs at higher risk, such as those with especially high job strain.

  20. Evaluation of indoor radon equilibrium factor using CFD modeling and resulting annual effective dose

    NASA Astrophysics Data System (ADS)

    Rabi, R.; Oufni, L.

    2018-04-01

    The equilibrium factor is an important parameter for reasonably estimating the population dose from radon. However, the equilibrium factor value depended mainly on the ventilation rate and the meteorological factors. Therefore, this study focuses on investigating numerically the influence of the ventilation rate, temperature and humidity on equilibrium factor between radon and its progeny. The numerical results showed that ventilation rate, temperature and humidity have significant impacts on indoor equilibrium factor. The variations of equilibrium factor with the ventilation, temperature and relative humidity are discussed. Moreover, the committed equivalent doses due to 218Po and 214Po radon short-lived progeny were evaluated in different tissues of the respiratory tract of the members of the public from the inhalation of indoor air. The annual effective dose due to radon short lived progeny from the inhalation of indoor air by the members of the public was investigated.

  1. Procedural justice and layoff survivors' commitment: a quantitative review.

    PubMed

    Grubb, W Lee

    2006-10-01

    Layoffs are common in today's organizations. Most studies that have examined the correlation between procedural justice and the organizational commitment of layoff survivors have yielded positive correlations, but the magnitude of the correlations varies widely. This study is the first to estimate the population correlation and to identify the primary sources that cause variation in the correlation across studies. The results indicated that justice and commitment correlations can always be expected to be positive. Based on a total sample size of 9080 individuals, the estimated mean population correlation was .34. Variation was primarily explained by attributes of the justice measure where multiple items scales and scales composed of both interactional and procedural justice items yielded higher correlations than single item measures. Therefore, it is important that employers recognize the substantial assuaging affect that procedural and interactional justice can have on survivors' organizational commitment.

  2. Community, Commitment and Congruence: A Different Kind of Excellence. A Preliminary Report on "The Future of the Academic Workplace in Liberal Arts Colleges."

    ERIC Educational Resources Information Center

    Splete, Allen P.; And Others

    A survey of faculty and selected administrators of liberal arts colleges was conducted, with the goals of achieving a greater understanding of the academic workplace for faculty in liberal arts colleges and identifying ways in which the vitality, commitment, morale, and productivity of the faculty could be enhanced. A total of 9,204 faculty in 142…

  3. Partnership for Continuous Improvement

    NASA Technical Reports Server (NTRS)

    1990-01-01

    The proceedings are presented of the sixth annual conference on quality control between NASA and its contractors. The emphasis is placed on a commitment to quality and excellence that guarantees mission success. A forum is provided for representatives from government, industry, and academia to exchange ideas and experiences, encouraging total quality performance that results in high quality products and services. Key points are highlighted from the presentations and activities are described that have resulted in a broad range of improvements in products and services from government, industry, and academia. Long term commitment to quality is an essential requirement that ensures future success. That commitment reinterates the dedication to excellence in space exploration and to national quality and productivity improvement.

  4. Causal relationship model between variables using linear regression to improve professional commitment of lecturer

    NASA Astrophysics Data System (ADS)

    Setyaningsih, S.

    2017-01-01

    The main element to build a leading university requires lecturer commitment in a professional manner. Commitment is measured through willpower, loyalty, pride, loyalty, and integrity as a professional lecturer. A total of 135 from 337 university lecturers were sampled to collect data. Data were analyzed using validity and reliability test and multiple linear regression. Many studies have found a link on the commitment of lecturers, but the basic cause of the causal relationship is generally neglected. These results indicate that the professional commitment of lecturers affected by variables empowerment, academic culture, and trust. The relationship model between variables is composed of three substructures. The first substructure consists of endogenous variables professional commitment and exogenous three variables, namely the academic culture, empowerment and trust, as well as residue variable ɛ y . The second substructure consists of one endogenous variable that is trust and two exogenous variables, namely empowerment and academic culture and the residue variable ɛ 3. The third substructure consists of one endogenous variable, namely the academic culture and exogenous variables, namely empowerment as well as residue variable ɛ 2. Multiple linear regression was used in the path model for each substructure. The results showed that the hypothesis has been proved and these findings provide empirical evidence that increasing the variables will have an impact on increasing the professional commitment of the lecturers.

  5. Job Involvement and Organizational Commitment of Employees of Prehospital Emergency Medical System

    PubMed Central

    Rahati, Alireza; Sotudeh-Arani, Hossein; Adib-Hajbaghery, Mohsen; Rostami, Majid

    2015-01-01

    Background: Several studies are available on organizational commitment of employees in different organizations. However, the organizational commitment and job involvement of the employees in the prehospital emergency medical system (PEMS) of Iran have largely been ignored. Objectives: This study aimed to investigate the organizational commitment and job involvement of the employees of PEMS and the relationship between these two issues. Materials and Methods: This cross-sectional study was conducted on 160 employees of Kashan PEMS who were selected through a census method in 2014. A 3-part instrument was used in this study, including a demographic questionnaire, the Allen and Miller’s organizational commitment inventory, and the Lodahl and Kejner’s job involvement inventory. We used descriptive statistics, Spearman correlation coefficient, Kruskal-Wallis, Friedman, analysis of variance, and Tukey post hoc tests to analyze the data. Results: The mean job involvement and organizational commitment scores were 61.78 ± 10.69 and 73.89 ± 13.58, respectively. The mean scores of job involvement and organizational commitment were significantly different in subjects with different work experiences (P = 0.043 and P = 0.012, respectively). However, no significant differences were observed between the mean scores of organizational commitment and job involvement in subjects with different fields of study, different levels of interest in the profession, and various educational levels. A direct significant correlation was found between the total scores of organizational commitment and job involvement of workers in Kashan PEMS (r = 0.910, P < 0.001). Conclusions: This study showed that the employees in the Kashan PEMS obtained half of the score of organizational commitment and about two-thirds of the job involvement score. Therefore, the higher level managers of the emergency medical system are advised to implement some strategies to increase the employees’ job involvement and organizational commitment. PMID:26835470

  6. Is it useful to assess annual effective doses that are less than 100 mSv?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strom, Daniel J.; Cameron, John R.

    It is useful to assess annual effective doses less than 100 mSv. Beyond the''score-keeping'' needs of regulatory compliance, there are at least seven other valid reasons for performing personnel monitoring, many of which fall into the category of''no news is good news,'' or more aptly,''null news, as long as you can prove it, is good news.'' These are performance measures for contractual compliance, diagnosis of problems with radiation protection programs, health surveillance and occupational epidemiology, prevention of and support for litigation, demonstration of management commitment and safety, worker counseling, ensuring peace of mind. Furthermore, it is shown that there ismore » very reasonable expectation that detriment may be associated with doses smaller than 100 mSv per year.« less

  7. [Healthcare research in forensic commitment or poking around in the dark : Consensus paper on the necessity for more uniform and better data].

    PubMed

    Querengässer, J; Bezzel, A; Hoffmann, K; Mache, W; Schiffer, B

    2017-11-01

    Complex trends in occupancy determined by many influencing factors, clear state-specific differences in imprisonment practices as well as recently implemented statutory alterations to the appropriate paragraphs in criminal law, underline the necessity for qualitative high-grade concomitant research of German forensic commitment; however, neither the structural prerequisites nor an adequate data situation are currently present in order to do justification to this aim. Not even the total number of patients currently accommodated in forensic commitment can be elucidated from the publicized (partial) statistics. This consensus paper, which was formulated by three research institutes active at the state level, describes the limited possibilities for current forensic healthcare research and raises the demand for a nationwide uniform data situation on patients in forensic commitment. Furthermore, how the appropriate elicitation instrument should be organizationally and structurally achieved, is sketched from a scientific perspective. This article aims at initiating a discussion on a sustainable improvement in the prerequisites for healthcare research in German forensic commitment and targets a sensitization of decision makers in politics and administration for this topic.

  8. Estimates of radiological risk from depleted uranium weapons in war scenarios.

    PubMed

    Durante, Marco; Pugliese, Mariagabriella

    2002-01-01

    Several weapons used during the recent conflict in Yugoslavia contain depleted uranium, including missiles and armor-piercing incendiary rounds. Health concern is related to the use of these weapons, because of the heavy-metal toxicity and radioactivity of uranium. Although chemical toxicity is considered the more important source of health risk related to uranium, radiation exposure has been allegedly related to cancers among veterans of the Balkan conflict, and uranium munitions are a possible source of contamination in the environment. Actual measurements of radioactive contamination are needed to assess the risk. In this paper, a computer simulation is proposed to estimate radiological risk related to different exposure scenarios. Dose caused by inhalation of radioactive aerosols and ground contamination induced by Tomahawk missile impact are simulated using a Gaussian plume model (HOTSPOT code). Environmental contamination and committed dose to the population resident in contaminated areas are predicted by a food-web model (RESRAD code). Small values of committed effective dose equivalent appear to be associated with missile impacts (50-y CEDE < 5 mSv), or population exposure by water-independent pathways (50-y CEDE < 80 mSv). The greatest hazard is related to the water contamination in conditions of effective leaching of uranium in the groundwater (50-y CEDE < 400 mSv). Even in this worst case scenario, the chemical toxicity largely predominates over radiological risk. These computer simulations suggest that little radiological risk is associated to the use of depleted uranium weapons.

  9. Interprofessional Emergency Training Leads to Changes in the Workplace

    PubMed Central

    Eisenmann, Dorothea; Stroben, Fabian; Gerken, Jan D.; Exadaktylos, Aristomenis K.; Machner, Mareen; Hautz, Wolf E.

    2018-01-01

    Introduction Preventable mistakes occur frequently and can lead to patient harm and death. The emergency department (ED) is notoriously prone to such errors, and evidence suggests that improving teamwork is a key aspect to reduce the rate of error in acute care settings. Only a few strategies are in place to train team skills and communication in interprofessional situations. Our goal was to conceptualize, implement, and evaluate a training module for students of three professions involved in emergency care. The objective was to sensitize participants to barriers for their team skills and communication across professional borders. Methods We developed a longitudinal simulation-enhanced training format for interprofessional teams, consisting of final-year medical students, advanced trainees of emergency nursing and student paramedics. The training format consisted of several one-day training modules, which took place twice in 2016 and 2017. Each training module started with an introduction to share one’s roles, professional self-concepts, common misconceptions, and communication barriers. Next, we conducted different simulated cases. Each case consisted of a prehospital section (for paramedics and medical students), a handover (everyone), and an ED section (medical students and emergency nurses). After each training module, we assessed participants’ “Commitment to Change.” In this questionnaire, students were anonymously asked to state up to three changes that they wished to implement as a result of the course, as well as the strength of their commitment to these changes. Results In total, 64 of 80 participants (80.0%) made at least one commitment to change after participating in the training modules. The total of 123 commitments was evenly distributed over four emerging categories: communication, behavior, knowledge and attitude. Roughly one third of behavior- and attitude-related commitments were directly related to interprofessional topics (e.g., “acknowledge other professions’ work”), and these were equally distributed among professions. At the two-month follow-up, 32 participants (50%) provided written feedback on their original commitments: 57 of 62 (91.9%) commitments were at least partly realized at the follow-up, and only five (8.1%) commitments lacked realization entirely. Conclusion A structured simulation-enhanced intervention was successful in promoting change to the practice of emergency care, while training teamwork and communication skills jointly. PMID:29383079

  10. Maintaining Professional Commitment as a Newly Credentialed Athletic Trainer in the Secondary School Setting.

    PubMed

    Mazerolle, Stephanie M; Myers, Sarah L; Walker, Stacy E; Kirby, Jessica

    2018-03-01

      Professional commitment, or one's affinity and loyalty to a career, has become a topic of interest in athletic training. The expanding research on the topic, however, has omitted newly credentialed athletic trainers (ATs). For an impressionable group of practitioners, transitioning to clinical practice can be stressful.   To explore the professional commitment of newly credentialed ATs in the secondary school setting.   Secondary school.   Qualitative study.   A total of 31 newly credentialed ATs (6 men, 25 women; mean age = 24 ± 3 years) participated. Of these, 17 ATs (4 men, 13 women; mean age = 25 ± 4 years) were employed full time in the secondary school setting, and 14 ATs (2 men, 12 women; mean age = 23.0 ± 2.0 years) were graduate assistant students in the secondary school setting.   All participants completed semistructured interviews, which focused on their experiences in the secondary school setting and transitioning into the role and setting. Transcripts were analyzed using the phenomenologic approach. Creditability was established by peer review, member checks, and researcher triangulation.   Four main findings related to the professional commitment of newly credentialed ATs in the secondary school setting were identified. Work-life balance, professional relationships formed with the student-athletes, enjoyment gained from working in the secondary school setting, and professional responsibility emerged as factors facilitating commitment.   Affective commitment is a primary facilitator of professional commitment. Newly credentialed ATs who enjoy their jobs and have time to engage in nonwork roles are able to maintain a positive professional commitment. Our findings align with the previous literature and help strengthen our understanding that rejuvenation and passion are important to professional commitment.

  11. Donor funding health policy and systems research in low- and middle-income countries: how much, from where and to whom.

    PubMed

    Grépin, Karen Ann; Pinkstaff, Crossley Beth; Shroff, Zubin Cyrus; Ghaffar, Abdul

    2017-08-31

    The need for sufficient and reliable funding to support health policy and systems research (HPSR) in low- and middle-income countries (LMICs) has been widely recognised. Currently, most resources to support such activities come from traditional development assistance for health (DAH) donors; however, few studies have examined the levels, trends, sources and national recipients of such support - a gap this research seeks to address. Using OECD's Creditor Reporting System database, we classified donor funding commitments using a keyword analysis of the project-level descriptions of donor supported projects to estimate total funding available for HPSR-related activities annually from bilateral and multilateral donors, as well as the Bill and Melinda Gates Foundation, to LMICs over the period 2000-2014. Total commitments to HPSR-related activities have greatly increased since 2000, peaked in 2010, and have held steady since 2011. Over the entire study period (2000-2014), donors committed a total of $4 billion in funding for HPSR-related activities or an average of $266 million a year. Over the last 5 years (2010-2014), donors committed an average of $434 million a year to HPSR-related activities. Funding for HPSR is heavily concentrated, with more than 93% coming from just 10 donors and only represents approximately 2% of all donor funding for health and population projects. Countries in the sub-Saharan African region are the major recipients of HPSR funding. Funding for HPSR-related activities has generally increased over the study period; however, donor support to such activities represents only a small proportion of total DAH and has not grown in recent years. Donors should consider increasing the proportion of funds they allocate to support HPSR activities in order to further build the evidence base on how to build stronger health systems.

  12. The University of Santo Tomas Viewed from the Lens of Total Quality Management: Implications to Total Quality Education

    ERIC Educational Resources Information Center

    de Guzman, Allan B.; Torres, Josefina R.

    2004-01-01

    Considered as a major management approach for improving organizational performance and competitive advantage, Total Quality Management (TQM) poses a challenge to dynamic institutions to adopt a systemic philosophy that places emphasis on customer needs and a commitment to a culture of excellence. Higher education institutions (HEIs) as learning…

  13. Lack of effect of a granulocyte proliferation inhibitor or their committed precursor cells.

    PubMed

    Lord, B I; Testa, N G; Wright, E G; Banerjee, R K

    1977-05-01

    Using the agar culture technique, we have measured the effect of granulocyte extracts GCE (and of erythrocyte-RCE and lymph node extracts-LNE) on the growth and proliferation of the committed granulocytic precursor cells, CFU-C. In addition we have determined their effects on the proliferation of the developing colony cells and on the ultimate cell production in the colonies. The results show that GCE has no effect on the growth or proliferative activity on the CFU-C. It does, however, reduce both the autoradiographic labelling indices of the developing colony cells and the net colony cellularities, acting as a cell cycle modulator. These are effects specific to the GCE since at the dose levels used, neither RCE nor LNE affected these measurements.

  14. Marrow toxicity of fractionated vs. single dose total body irradiation is identical in a canine model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Storb, R.; Raff, R.F.; Graham, T.

    1993-03-20

    The authors explored in dogs the marrow toxicity of single dose total body irradiation delivered from two opposing [sup 60]Co sources at a rate of 10 cGy/min and compared results to those seen with total body irradiation administered in 100 cGy fractions with minimum interfraction intervals of 6 hr. Dogs were not given marrow transplants. They found that 200 cGy single dose total body irradiation was sublethal, with 12 of 13 dogs showing hematopoietic recovery and survival. Seven of 21 dogs given 300 cGy single dose total body irradiation survived compared to 6 of 10 dogs given 300 cGy fractionatedmore » total body irradiation. One of 28 dogs given 400 cGy single dose total body irradiation survived compared to none of six given fractionated radiation. With granulocyte colony stimulating factor (GCSF) administered from day 0-21 after 400 cGy total body irradiation, most dogs survived with hematological recovery. Because of the almost uniform success with GCSF after 400 cGy single dose total body irradiation, a study of GCSF after 400 cGy fractionated total body irradiation was deemed not to be informative and, thus, not carried out. Additional comparisons between single dose and fractionated total body irradiation were carried out with GCSF administered after 500 and 600 cGy of total body irradiation. As with lower doses of total body irradiation, no significant survival differences were seen between the two modes of total body irradiation, and only 3 of 26 dogs studied survived with complete hematological recovery. Overall, therefore, survival among dogs given single dose total body irradiation was not different from that of dogs given fractionated total body irradiation (p = .67). Similarly, the slopes of the postirradiation declines of granulocyte and platelet counts and the rates of their recovery in surviving dogs given equal total doses of single versus fractionated total body irradiation were indistinguishable. 24 refs., 3 figs., 2 tabs.« less

  15. Empowering workplace and wellbeing among healthcare professionals: the buffering role of job control.

    PubMed

    Galletta, Maura; Portoghese, Igor; Fabbri, Daniele; Pilia, Ilaria; Campagna, Marcello

    2016-05-26

    Health care workers are exposed to several job stressors that can adversely affect their wellbeing. Workplace incivility is a growing organizational concern with the potential to create workplaces harmful to individuals' wellbeing and increase occupational health risks. Based on the Job Demands-Resources (JD-R) model, the purpose of the present study was to investigate the role of two resources (organizational empowerment and job control) on individuals' well-being (emotional exhaustion) and attitude at work (unit affective commitment). A total of 210 hospital workers completed a self-administered questionnaire that was used to measure organizational empowerment, workplace incivility, job control, exhaustion, and affective commitment. Data were collected in 2014. Data were examined via linear regression analyses. The results showed that workplace incivility was positively related to emotional exhaustion and negatively related to affective commitment. Workplace empowerment was positively related to affective commitment and negatively related to emotional exhaustion. Furthermore, the positive relationship between workplace empowerment and affective commitment was significantly moderated by job control. Our results found support for the JD-R model. Specifically, results showed the buffering effect of job control in the relationship between empowerment and affective commitment. Our findings may concretely contribute to the stress literature and offer additional suggestions to promote healthy workplaces.

  16. The mediating role of organizational subcultures in health care organizations.

    PubMed

    Lok, Peter; Rhodes, Jo; Westwood, Bob

    2011-01-01

    This study aims to investigate the mediating role of organizational subculture between job satisfaction, organizational commitment (dependent variables) and leadership, culture (independent variables) in health care organizations. A survey on nurses from 26 wards from various types of hospital was used. A total of 251 usable returns were collected for the analysis (i.e. response rate of 63 per cent). Structural equation analysis was conducted to obtain the best fit model and to determine the direction of the causal effect between job satisfaction and commitment, and the role of subculture as a mediating variable, between commitment of its other antecedents. Comparisons with alternative models confirmed satisfaction as an antecedent of commitment and the role of subculture as a mediating variable. The results of this study contribute to the clarification of the causal relations of the antecedents of commitment, and highlight the important role of local leadership and subculture in determining employees' job satisfaction and commitment. The results of this study should not be generalized to other industries and other national cultural context. Furthermore, a longitudinal study may be necessary to determine the causal relationship of variables used in this study. The findings could provide managers with valuable insight to focus their limited resources on improving the level of organizational commitment via the mediating role of organizational culture. The research findings provide managers with a new lens to examine organizational culture using the three perspectives of: bureaucratic, supportive, and innovative. Furthermore, the results could renew interest in developing other organizational subculture models that determine the relationship between organizational subculture and commitment

  17. Food safety regulations: what we learned from the Fukushima nuclear accident.

    PubMed

    Hamada, Nobuyuki; Ogino, Haruyuki

    2012-09-01

    On 11 March 2011, the magnitude-9.0 earthquake and a substantial tsunami struck off the northeast coast of Japan. The Fukushima nuclear power plants were inundated and stricken, followed by radionuclide releases outside the crippled reactors. Provisional regulation values for radioactivity in food and drink were set on 17 March and were adopted from the preset index values, except that for radioiodines in water and milk ingested by infants. For radiocesiums, uranium, plutonium and transuranic α emitters, index values were defined in all food and drink not to exceed a committed effective dose of 5 mSv/year. Index values for radioiodines were defined not to exceed a committed equivalent dose to the thyroid of 50 mSv/year, and set in water, milk and some vegetables, but not in other foodstuffs. Index values were calculated as radioactive concentrations of indicator radionuclides ((131)I for radioiodines, (134)Cs and (137)Cs for radiocesiums) by postulating the relative radioactive concentration of coexisting radionuclides (e.g., (132)I, (133)I, (134)I, (135)I and (132)Te for (131)I). Surveys were thence conducted to monitor levels of (131)I, (134)Cs and (137)Cs. Provisional regulation values were exceeded in tap water, raw milk and some vegetables, and restrictions on distribution and consumption began on 21 March. Fish contaminated with radioiodines at levels of concern were then detected, so that the provisional regulation value for radioiodines in seafood adopted from that in vegetables were additionally set on 5 April. Overall, restrictions started within 25 days after the first excess in each food or drink item, and maximum levels were detected in leafy vegetables (54,100 Bq/kg for (131)I, and a total of 82,000 Bq/kg for (134)Cs and (137)Cs). This paper focuses on the logic behind such food safety regulations, and discusses its underlying issues. The outlines of the food monitoring results for 24,685 samples and the enforced restrictions will also be described. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Problem Solving Teams in a Total Quality Management Environment.

    ERIC Educational Resources Information Center

    Towler, Constance F.

    1993-01-01

    Outlines the problem-solving team training process used at Harvard University (Massachusetts), including the size and formation of teams, roles, and time commitment. Components of the process are explained, including introduction to Total Quality Management (TQM), customer satisfaction, meeting management, Parker Team Player Survey, interactive…

  19. Clinical-scale expansion of CD34+ cord blood cells amplifies committed progenitors and rapid scid repopulation cells.

    PubMed

    Casamayor-Genescà, Alba; Pla, Arnau; Oliver-Vila, Irene; Pujals-Fonts, Noèlia; Marín-Gallén, Sílvia; Caminal, Marta; Pujol-Autonell, Irma; Carrascal, Jorge; Vives-Pi, Marta; Garcia, Joan; Vives, Joaquim

    2017-03-25

    Umbilical cord blood (UCB) transplantation is associated with long periods of aplastic anaemia. This undesirable situation is due to the low cell dose available per unit of UCB and the immaturity of its progenitors. To overcome this, we present a cell culture strategy aimed at the expansion of the CD34 + population and the generation of granulocyte lineage-committed progenitors. Two culture products were produced after either 6 or 14days of in vitro expansion, and their characteristics compared to non-expanded UCB CD34 + controls in terms of phenotype, colony-forming activity and multilineage repopulation potential in NOD-scid IL2Rγ null mice. Both expanded cell products maintained rapid SCID repopulation activity similar to the non-expanded control, but 14-day cultured cells showed impaired long term SCID repopulation activity. The process was successfully scaled up to clinically relevant doses of 89×10 6 CD34 + cells committed to the granulocytic lineage and 3.9×10 9 neutrophil precursors in different maturation stages. Cell yields and biological properties presented by the cell product obtained after 14days in culture were superior and therefore this is proposed as the preferred production setup in a new type of dual transplant strategy to reduce aplastic periods, producing a transient repopulation before the definitive engraftment of the non-cultured UCB unit. Importantly, human telomerase reverse transcriptase activity was undetectable, c-myc expression levels were low and no genetic abnormalities were found, as determined by G-banding karyotype, further confirming the safety of the expanded product. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Does smoking cannabis affect work commitment?

    PubMed

    Hyggen, Christer

    2012-07-01

      This study aimed to examine the associations between cannabis use and work commitment.   We used a 25-year panel survey initiated in 1985 with follow-ups in 1987, 1989, 1993, 2003 and 2010. Registered data from a range of public registers were matched with individual responses for the entire period.   The panel survey was a nation-wide study set in Norway.   A total of 1997 respondents born between 1965 and 1968 were included in the panel.   Work involvement scale (WIS) was used to assess work commitment. Involvement with cannabis was based on self-reported smoking of cannabis within the last 12 months and exposure to cannabis through friends. This information was categorized into 'abstaining', 'exposed', 'experimented' and 'involved'. Control measures included socio-economic background, mental health (HSCL-10), education, work satisfaction, unemployment, receipt of social assistance, consumption of alcohol, alcohol-related problems and use of other illicit drugs.   The level of work commitment was associated with involvement with cannabis. In 1993, when the respondents were in their mid-20s, those who were involved or had experimented with cannabis displayed lower levels of work commitment than those who were abstaining or merely exposed to cannabis through friends (P < 0.05). Work commitment among those who experimented with cannabis converged towards the levels reported by abstainers and the exposed as they grew older, whereas those involved reported decreasing work commitment into adulthood (P < 0.001). Using linear regression models for panel data, an association with continued use of cannabis across the life-course and a lowering of work commitment was established. Results remained significant even when controlling for a range of other factors known to be related to work commitment, such as socio-economic background, education, labour market experiences, mental health and family characteristics (P < 0.05).   In Norway the use of cannabis is associated with a reduction in work commitment among adults. © 2012 The Author, Addiction © 2012 Society for the Study of Addiction.

  1. DESC (Defense Electronics Supply Center) Total Quality Management Plan

    DTIC Science & Technology

    1989-04-01

    Paoerwort Reduction Proodt(0704.01 ge. Washington. DC 20S03 4. TITLE AND SUBTITLE Api598 . FUNDING NUMBERS DESC Total Quality Management Master Plan...OF PAGES TQM (Total Quality Management ), Continuous Process Improvement,_________ cTainingManagement 16. PRICE CODE 17. SECURITY CLASSIFICATION 18... QUALITY MANAGEMENT As you read the DESC Total Quality Management Plan, I ask each of you to make a commitment to continuously strive for improvement

  2. Total Quality Management in Higher Education.

    ERIC Educational Resources Information Center

    Sherr, Lawrence A.; Lozier, G. Gredgory

    1991-01-01

    Total Quality Management, based on theories of W. Edward Deming and others, is a style of management using continuous process improvement characterized by mission and customer focus, a systematic approach to operations, vigorous development of human resources, long-term thinking, and a commitment to ensuring quality. The values espoused by this…

  3. Notes on TQM (Total Quality Management) and Education

    ERIC Educational Resources Information Center

    Daniel, Carter A.

    2005-01-01

    Application of Deming's TQM principles to education is long overdue. Principles that have proven their worth in businesses for decades could revolutionize our thinking about education. But they require a total commitment, from the highest to the lowest level. Deming's 14 points, and Gray Rinehart's suggestions, are presented, discussed, and…

  4. Teaching Corporate Culture Using Interactive Video Training.

    ERIC Educational Resources Information Center

    Gardner, P. R.

    The Westinghouse Hanford Company Total Quality Program includes the development of Hanford General Employee Training (HGET), an interactive video course. The commitment to total quality is developed in both new and requalifying employees by requiring them to make positive choices when confronted with real life scenarios showing violations of…

  5. 24 CFR 882.403 - ACC, housing assistance payments contract, and lease.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 4 2011-04-01 2011-04-01 false ACC, housing assistance payments... Procedures for Moderate Rehabilitation-Basic Policies § 882.403 ACC, housing assistance payments contract, and lease. (a) Maximum Total ACC Commitments. The maximum total annual contribution that may be...

  6. 49 CFR 244.9 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... railroad operations, including, but not limited to, the allocation of resources affecting railroad... deflator formula) from time to time. Corporate culture means the totality of the commitments, written and...

  7. 49 CFR 244.9 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... railroad operations, including, but not limited to, the allocation of resources affecting railroad... deflator formula) from time to time. Corporate culture means the totality of the commitments, written and...

  8. 49 CFR 244.9 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... railroad operations, including, but not limited to, the allocation of resources affecting railroad... deflator formula) from time to time. Corporate culture means the totality of the commitments, written and...

  9. 49 CFR 244.9 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... railroad operations, including, but not limited to, the allocation of resources affecting railroad... deflator formula) from time to time. Corporate culture means the totality of the commitments, written and...

  10. Psychometric properties of the "sport satisfaction instrument (SSI)" in female athletes: predictive model of sport commitment.

    PubMed

    Granero-Gallegos, A; Baena-Extremera, A; Gómez-López, M; Abraldes, J A

    2014-08-01

    The objective of this research was to assess the psychometric properties of the Sport Satisfaction Instrument (SSI) in a Spanish sample of female athletes in team sports federations, to decide whether it constitutes a valid and reliable instrument to be used in the context of female competitive sport in future research. The SSI was administered to a total of 615 athletes from 12 to 38 yr. of age. Confirmatory procedures and psychometric analysis supported the hypothesized theoretical model of two factors (Satisfaction/fun and Boredom). For female athletes, the 7-item model showed better goodness-of-fit indexes upon eliminating Item 2 from the Boredom subscale. Concurrent validity was explored through the correlations with the Perception of Success Questionnaire and Sport Commitment, obtaining positive correlations between Satisfaction/fun and Task Orientation and Sport Commitment, whereas Boredom correlated positively but less closely with Ego Orientation. The importance of Satisfaction/fun in the prediction of Sport Commitment, starting from task orientation, is emphasized.

  11. Nurses well-being in intensive care units: study of factors promoting team commitment.

    PubMed

    Galletta, Maura; Portoghese, Igor; Coppola, Rosa C; Finco, Gabriele; Campagna, Marcello

    2016-05-01

    Intensive care units (ICUs) are challenging work environments because of the critical condition of patients, and ICU nurses frequently lament low job satisfaction and high staff turnover. Nevertheless, organizational and work characteristics, and the quality of relationships with staff can help to maintain nurses' enthusiasm and increase job satisfaction. The aim of this study was to analyse how nursing work environment factors affect identification and commitment among ICU nurses. A cross-sectional study was carried out in 12 ICUs from four Italian urban hospitals. A total of 222 nurses participated and completed a self-reported questionnaire. Results show that nursing work characteristics are directly related to team commitment, and that the nursing work characteristics and team commitment relationship was mediated by both perceived supervisor support and job satisfaction. Our findings may concretely contribute to literature and offer additional suggestions to improve nurses' work conditions and patient health in ICUs. © 2014 British Association of Critical Care Nurses.

  12. Passion, Intimacy, and Commitment in Casual Sexual Relationships in a Canadian Sample of Emerging Adults.

    PubMed

    Rodrigue, Carl; Blais, Martin; Lavoie, Francine; Adam, Barry D; Goyer, Marie-France; Magontier, Céline

    2017-12-04

    Research on casual sexual relationships (CSRs) among emerging adults is prevalent, yet our empirical and theoretical knowledge of relationship processes involved in these relationships is limited. The present study's objective was to compare four CSR partner types (acquaintance, friend, non-dating partner, ex-romantic partner) on passion, intimacy, and commitment, the components of Sternberg's triangular theory of love. A total of 441 Canadians aged 18-25 years who were not in a romantic relationship, and who reported having had more than one sexual contact with their last CSR partner, completed an online survey. Across all partner types, passion was highest, followed by intimacy and commitment. Levels of passion, intimacy, and commitment generally increased with partner familiarity. However, CSR partner type differences on the three components were partially explained by CSR components (i.e., frequency of sexual activity, frequency of social activity, whether partners saw each other with the main goal of having sex, sexual exclusivity agreement, and hopes about the relationship). Results are consistent with CSRs' emphasis on sexuality, and, to a lesser extent, emotions. However, they challenge the mainstream and scientific conflation of CSRs with an absence of emotional bond, commitment, or love.

  13. Hardiness commitment, gender, and age differentiate university academic performance.

    PubMed

    Sheard, Michael

    2009-03-01

    The increasing diversity of students, particularly in age, attending university has seen a concomitant interest in factors predicting academic success. This 2-year correlational study examined whether age, gender (demographic variables), and hardiness (cognitive/emotional variable) differentiate and predict university final degree grade point average (GPA) and final-year dissertation mark. Data are reported from a total of 134 university undergraduate students. Participants provided baseline data in questionnaires administered during the first week of their second year of undergraduate study and gave consent for their academic progress to be tracked. Final degree GPA and dissertation mark were the academic performance criteria. Mature-age students achieved higher final degree GPA compared to young undergraduates. Female students significantly outperformed their male counterparts in each measured academic assessment criteria. Female students also reported a significantly higher mean score on hardiness commitment compared to male students. commitment was the most significant positive correlate of academic achievement. Final degree GPA and dissertation mark were significantly predicted by commitment, and commitment and gender, respectively. The findings have implications for universities targeting academic support services to maximize student scholastic potential. Future research should incorporate hardiness, gender, and age with other variables known to predict academic success.

  14. Situational leadership styles, staff nurse job characteristics related to job satisfaction and organizational commitment of head nurses working in hospitals under the jurisdiction of the Royal Thai Army.

    PubMed

    Intaraprasong, Bhusita; Potjanasitt, Sureporn; Pattaraarchachai, Junya; Meennuch, Chavalit

    2012-06-01

    To analyze the relationships between the situational leadership styles, staff nurse job characteristic with job satisfaction and organizational commitment of head nurses working in hospitals under the jurisdiction of the Royal Thai Army The cross-sectional analytical study was conducted in 128 head nurses working in hospitals under the jurisdiction of the Royal Thai Army. Data were collected by mailed questionnaires. A total of 117 completed questionnaires (91.4%) were received for analysis. Statistical analysis was done using Pearson's Product Moment Correlation Coefficient. It was found that situational leadership styles were not correlated with job satisfaction and organizational commitment of head nurses. Staff nurse job characteristics had a low level of positive correlation with job satisfaction and organizational commitment of head nurses at 0.05 level of significance (r = 0.202 and 0.189 respectively). The hospital administrators should formulate policy to improve working system, human resource management and formulate policies and strategies based on situational leadership. In addition, they should improve the characteristics of staff nurse job by using surveys to obtain job satisfaction and organizational commitment.

  15. The effects of organizational commitment and structural empowerment on patient safety culture.

    PubMed

    Horwitz, Sujin K; Horwitz, Irwin B

    2017-03-20

    Purpose The purpose of this paper is to investigate the relationship between patient safety culture and two attitudinal constructs: affective organizational commitment and structural empowerment. In doing so, the main and interaction effects of the two constructs on the perception of patient safety culture were assessed using a cohort of physicians. Design/methodology/approach Affective commitment was measured with the Organizational Commitment Questionnaire, whereas structural empowerment was assessed with the Conditions of Work Effectiveness Questionnaire-II. The abbreviated versions of these surveys were administered to a cohort of 71 post-doctoral medical residents. For the data analysis, hierarchical regression analyses were performed for the main and interaction effects of affective commitment and structural empowerment on the perception of patient safety culture. Findings A total of 63 surveys were analyzed. The results revealed that both affective commitment and structural empowerment were positively related to patient safety culture. A potential interaction effect of the two attitudinal constructs on patient safety culture was tested but no such effect was detected. Research limitations/implications This study suggests that there are potential benefits of promoting affective commitment and structural empowerment for patient safety culture in health care organizations. By identifying the positive associations between the two constructs and patient safety culture, this study provides additional empirical support for Kanter's theoretical tenet that structural and organizational support together helps to shape the perceptions of patient safety culture. Originality/value Despite the wide recognition of employee empowerment and commitment in organizational research, there has still been a paucity of empirical studies specifically assessing their effects on patient safety culture in health care organizations. To the authors' knowledge, this study is the first empirical study to examine the relationship between structural empowerment as proposed by Kanter and the culture of patient safety using physicians.

  16. Ionizing Radiation Dose Due to the Use of Agricultural Fertilizers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Umisedo, Nancy K.; Okuno, Emico; Medina, Nilberto H.

    2008-08-07

    The transference of radionuclides from the fertilizers to/and from soils to the foodstuffs can represent an increment in the internal dose when the vegetables are consumed by the human beings. This work evaluates the contribution of fertilizers to the increase of radiation level in the environment and of dose to the people. Samples of fertilizers, soils and vegetables produced in farms located in the neighbourhood of Sao Paulo city in the State of Sao Paulo, Brazil were analysed through gamma spectroscopy. The values of specific activity of {sup 40}K, {sup 238}U and {sup 232}Th show that there is no significantmore » transference of natural radionuclides from fertilizers to the final product of the food chain. The annual committed effective dose due to the ingestion of {sup 40}K contained in the group of consumed vegetables analysed in this work resulted in the very low value of 0.882 {mu}Sv.« less

  17. Determination of in vitro lung solubility and intake-to-dose conversion factor for tritiated lanthanum nickel aluminum alloy.

    PubMed

    Farfán, Eduardo B; Labone, Thomas R; Staack, Gregory C; Cheng, Yung-Sung; Zhou, Yue; Varallo, Thomas P

    2012-09-01

    A sample of tritiated lanthanum nickel aluminum alloy (LaNi4.25Al0.75 or LANA.75) similar to that used at the Savannah River Site Tritium Facilities was analyzed to estimate the particle size distribution of this metal tritide powder and the rate at which this material dissolves in the human respiratory tract after it is inhaled. This information is used to calculate the committed effective dose received by a worker after inhaling the material. These doses, which were calculated using the same methodology given in the U.S. Department of Energy Tritium Handbook, are presented as inhalation intake-to-dose conversion factors (DCF). The DCF for this metal tritide was determined to be 9.4 × 10 Sv Bq, which is less than the DCF for tritiated water. Therefore, the radiation worker bioassay programs designed for tritiated water are adequate to monitor for intakes of this material.

  18. Low Doses of Imatinib Induce Myelopoiesis and Enhance Host Anti-microbial Immunity

    PubMed Central

    Swimm, Alyson; Giver, Cynthia R.; Harris, Wayne A. C.; Laval, Julie; Napier, Brooke A.; Patel, Gopi; Crump, Ryan; Peng, Zhenghong; Bornmann, William; Pulendran, Bali; Buller, R. Mark; Weiss, David S.; Tirouvanziam, Rabindra; Waller, Edmund K.; Kalman, Daniel

    2015-01-01

    Imatinib mesylate (Gleevec) inhibits Abl1, c-Kit, and related protein tyrosine kinases (PTKs) and serves as a therapeutic for chronic myelogenous leukemia and gastrointestinal stromal tumors. Imatinib also has efficacy against various pathogens, including pathogenic mycobacteria, where it decreases bacterial load in mice, albeit at doses below those used for treating cancer. We report that imatinib at such low doses unexpectedly induces differentiation of hematopoietic stem cells and progenitors in the bone marrow, augments myelopoiesis but not lymphopoiesis, and increases numbers of myeloid cells in blood and spleen. Whereas progenitor differentiation relies on partial inhibition of c-Kit by imatinib, lineage commitment depends upon inhibition of other PTKs. Thus, imatinib mimics “emergency hematopoiesis,” a physiological innate immune response to infection. Increasing neutrophil numbers by adoptive transfer sufficed to reduce mycobacterial load, and imatinib reduced bacterial load of Franciscella spp., which do not utilize imatinib-sensitive PTKs for pathogenesis. Thus, potentiation of the immune response by imatinib at low doses may facilitate clearance of diverse microbial pathogens. PMID:25822986

  19. Low doses of imatinib induce myelopoiesis and enhance host anti-microbial immunity.

    PubMed

    Napier, Ruth J; Norris, Brian A; Swimm, Alyson; Giver, Cynthia R; Harris, Wayne A C; Laval, Julie; Napier, Brooke A; Patel, Gopi; Crump, Ryan; Peng, Zhenghong; Bornmann, William; Pulendran, Bali; Buller, R Mark; Weiss, David S; Tirouvanziam, Rabindra; Waller, Edmund K; Kalman, Daniel

    2015-03-01

    Imatinib mesylate (Gleevec) inhibits Abl1, c-Kit, and related protein tyrosine kinases (PTKs) and serves as a therapeutic for chronic myelogenous leukemia and gastrointestinal stromal tumors. Imatinib also has efficacy against various pathogens, including pathogenic mycobacteria, where it decreases bacterial load in mice, albeit at doses below those used for treating cancer. We report that imatinib at such low doses unexpectedly induces differentiation of hematopoietic stem cells and progenitors in the bone marrow, augments myelopoiesis but not lymphopoiesis, and increases numbers of myeloid cells in blood and spleen. Whereas progenitor differentiation relies on partial inhibition of c-Kit by imatinib, lineage commitment depends upon inhibition of other PTKs. Thus, imatinib mimics "emergency hematopoiesis," a physiological innate immune response to infection. Increasing neutrophil numbers by adoptive transfer sufficed to reduce mycobacterial load, and imatinib reduced bacterial load of Franciscella spp., which do not utilize imatinib-sensitive PTKs for pathogenesis. Thus, potentiation of the immune response by imatinib at low doses may facilitate clearance of diverse microbial pathogens.

  20. A Supply and Demand Management Perspective on the Accelerated Global Introductions of Inactivated Poliovirus Vaccine in a Constrained Supply Market

    PubMed Central

    Ottosen, Ann; Rubin, Jennifer; Blanc, Diana Chang; Zipursky, Simona; Wootton, Emily

    2017-01-01

    Abstract A total of 105 countries have introduced IPV as of September 2016 of which 85 have procured the vaccine through UNICEF. The Global Eradication and Endgame Strategic Plan 2013-2018 called for the rapid introduction of at least one dose of IPV into routine immunization schedules in 126 all OPV-using countries by the end of 2015. At the time of initiating the procurement process, demand was estimated based on global modeling rather than individual country indications. In its capacity as procurement agency for the Global Polio Eradication Initiative and Gavi, the Vaccine Alliance, UNICEF set out to secure access to IPV supply for around 100 countries. Based on offers received, sufficient supply was awarded to two manufacturers to meet projected routine requirements. However, due to technical issues scaling up vaccine production and an unforecasted demand for IPV use in campaigns to interrupt wild polio virus and to control type 2 vaccine derived polio virus outbreaks, IPV supplies are severely constrained. Activities to stretch supplies and to suppress demand have been ongoing since 2014, including delaying IPV introduction in countries where risks of type 2 reintroduction are lower, implementing the multi-dose vial policy, and encouraging the use of fractional dose delivered intradermally. Despite these efforts, there is still insufficient IPV supply to meet demand. The impact of the supply situation on IPV introduction timelines in countries are the focus of this article, and based on lessons learned with the IPV introductions, it is recommended for future health programs with accelerated scale up of programs, to take a cautious approach on supply commitments, putting in place clear allocation criteria in case of shortages or delays and establishing a communication strategy vis a vis beneficiaries. PMID:28838159

  1. Comparison of Alcohol Impairment of Behavioral and Attentional Inhibition

    PubMed Central

    Weafer, Jessica; Fillmore, Mark T.

    2012-01-01

    Background Despite the wealth of studies demonstrating the impairing effects of alcohol on behavioral inhibition, less is known regarding effects of the drug on attentional inhibition (i.e., the ability to ignore distracting stimuli in the environment in order to focus attention on relevant information). The current study examined alcohol impairment of both behavioral and attentional inhibition, as well as potential associations between the two mechanisms of inhibitory control. Methods Men (n = 27) and women (n = 21) performed a measure of behavioral inhibition (cued go/no-go task) and a measure of attentional inhibition (delayed ocular return task) following three doses of alcohol: 0.65 g/kg, 0.45 g/kg, and 0.0 g/kg (placebo). Results Alcohol impaired both behavioral and attentional inhibition relative to placebo; however, correlational analyses revealed no associations between measures of behavioral and attentional inhibition following any dose. Additionally, men committed more inhibitory failures on the behavioral inhibition task, whereas women committed more inhibitory failures on the attentional inhibition task. Conclusions These findings suggest that behavioral and attentional inhibition are equally sensitive to the impairing effects of alcohol, yet represent distinct components of inhibitory control. Additionally, the observed gender differences in control of behavior and attention could have important implications regarding negative consequences associated with alcohol-induced disinhibition in men and women. PMID:22673197

  2. Dietary intake of 210Po and 210Pb in the environment of Goa of south-west Coast of India.

    PubMed

    Avadhani, D N; Mahesh, H M; Karunakara, N; Narayana, Y; Somashekarappa, H M; Siddappa, K

    2001-10-01

    This paper deals with the distribution and activity intake of 210Po and 210Pb in food, diet, and potable water samples of the Goa region and the estimated committed effective dose due to ingestion of these radionuclides. The activity concentrations of 210Po and 210Pb were determined in about 30 food and diet samples from different places of Goa in order to know the distribution and intake of these radionuclides. The activity concentration of 210Po in fish and prawn samples were significantly higher than concentrations found in vegetable and rice samples. Higher concentrations of 210Po and 210Pb were observed in leafy vegetables than in non-leafy vegetables. Among the diet samples the activity concentrations of 210Po and 210Pb in non-vegetarian meal samples were relatively higher than in vegetarian meal and breakfast samples. The committed effective dose due to annual intake of 210Po was found to be 94.6 microSv, 49.1 microSv, 10.5 microSv, and 2.2 microSv and that of 210Pb found to be 81.6 microSv, 59.9 microSv, 14.6 microSv, and 2.0 microSv for the ingestion of non-vegetarian meal, vegetarian meal, breakfast, and potable water, respectively.

  3. Environmental analysis burial of offsite low-level waste at SRP

    NASA Astrophysics Data System (ADS)

    Poe, W. L.; Moyer, R. A.

    1980-12-01

    The environmental effects of receipt and burial of low level naval waste are assessed. This low level waste was sent to the NRC-licensed burial ground operated by Chem-Nuclear Systems, Inc., at Barnwell, South Carolina. The DOE announced that DOE-generated low level waste would no longer be buried at commercial waste burial sites. The SRP was selected to receive the Naval waste described in this analysis. Receipt and burial of these wastes will have a negligible effect on SRP's environment and increase only sightly the environmental effects of the SRP operations discussed in the EIS on SRP waste management operations. The environmental effects of burial of this waste at Chem-Nuclear Burial Ground or at the SRP Burial Ground are described in this environmental analysis to permit assessment of incremental effects caused by the decision to bury this Naval waste in the SRP Burial Ground rather than in the Barnwell Burial Ground. The radiological effects from burial of this waste in either the SRP or Chem-Nuclear Burial Ground are very small when compared to those from natural background radiation or to the annual population dose commitment from operation of SRP. The environmental effects of burial at SRP to dose commitments normally received by the population surrounding SRP are compared.

  4. A solution to the shortage of nursing faculty: awareness and understanding of the leadership style of the nursing department head.

    PubMed

    Byrne, Daria M; Martin, Barbara N

    2014-01-01

    The purpose of this research was to determine if there was a relationship between the leadership style of the nursing department head and the level of professional satisfaction and organizational commitment by nursing faculty members. The survey instrument was designed to measure the department heads' leadership style as perceived by the nursing faculty and assess the nursing faculty members' level of professional satisfaction and organizational commitment. Five schools of nursing in 2 Midwestern states, with a total of 52 full-time baccalaureate nursing faculty, were the focus of the inquiry. Findings support statistically significant relationships between the 3 variables of department head leadership, organizational commitment, and professional satisfaction. Implications for leadership style exhibited by the nursing department head are discussed.

  5. Just-in-time: maximizing its success potential.

    PubMed

    Johnston, S K

    1990-08-01

    The effective implementation and use of JIT manufacturing practices depends largely on the education, training, and commitment of all levels of management to a fundamental quality-first policy. Management must transfer and demonstrate that commitment to every level and extension of the manufacturing endeavor. As a company establishes and reaches toward that goal, the move to JIT manufacturing practices becomes rational and justifiable. Failing to establish and commit to a quality directive greatly diminishes the potential benefits of JIT. If all levels of manufacturing participate in the JIT planning, implementing, and maintenance procedure, the realization of positive change and improvement drives the process. Total participation makes the task of JIT implementation not only possible, but practical. Enhanced mutual respect for all concerned is a likely consequence, advancing the productive environment.

  6. The Total Quality Management Model Department of Personnel State of Colorado,

    DTIC Science & Technology

    A panel of three members will present the Total Quality Management model recently designed for the Department of Personnel, State of Colorado. This model was selected to increase work quality and productivity of the Department and to exemplify Governor Romer’s commitment to quality work within state government.

  7. Novel Measure of Opioid Dose and Costs of Care for Diabetes Mellitus: Opioid Dose and Health Care Costs.

    PubMed

    Gautam, Santosh; Franzini, Luisa; Mikhail, Osama I; Chan, Wenyaw; Turner, Barbara J

    2016-03-01

    Diabetes mellitus (DM) has well known costly complications but we hypothesized that costs of care for chronic pain treated with opioid analgesic (OA) medications would also be substantial. In a statewide, privately insured cohort of 29,033 adults aged 18 to 64 years with DM and noncancer pain who filled OA prescription(s) from 2008 to 2012, our outcomes were costs for specific health care services and total costs per 6-month intervals after the first filled OA prescription. Average daily OA dose (4 categories) and total dose (quartiles) in morphine-equivalent milligrams were calculated per 6-month interval after the first OA prescription and combined into a novel OA dose measure. Associations of OA measures with costs of care (n = 126,854 6-month intervals) were examined using generalized estimating equations adjusted for clinical conditions, psychotherapeutic drugs, and DM treatment. Incremental costs for each type of health care service and total cost of care increased progressively with average daily and total OA dose versus no OAs. The combined OA measure identified the highest incremental total costs per 6-month interval that were increased by $8,389 for 50- to 99-mg average daily dose plus >900 mg total dose and, by $9,181 and $9,958 respectively, for ≥100 mg average daily dose plus 301- to 900-mg or >900 mg total dose. In this statewide DM cohort, total health care costs per 6-month interval increased progressively with higher average daily OA dose and with total OA dose but the greatest increases of >$8,000 were distinguished by combinations of higher average daily and total OA doses. The higher costs of care for opioid-treated patients appeared for all types of services and likely reflects multiple factors including morbidity from the underlying cause of pain, care and complications related to opioid use, and poorer control of diabetes as found in other studies. Copyright © 2016 American Pain Society. Published by Elsevier Inc. All rights reserved.

  8. The effect of nursing internship program on burnout and professional commitment.

    PubMed

    Ayaz-Alkaya, Sultan; Yaman-Sözbir, Şengül; Bayrak-Kahraman, Burcu

    2018-05-26

    Professional commitment is defined as a belief in and acceptance of the values of the profession which is chosen, effort to actualize these values, desire to improve him/herself. Nurses' professional and organizational commitment are influenced by factors such as job stress, job satisfaction and burnout. This study was conducted to determine the effect of nursing internship program on professional commitment and burnout of senior nursing students. A quasi-experimental study with a pretest and posttest without control group design was used. Students who were attending nursing internship program and agreed to participate were included in the study. Sample consisted of 101 students. Data were collected with a questionnaire, the burnout measure short version and nursing professional commitment scale. After the nursing internship, 77.2% were pleased to study nursing, 83.2% were pleased to be a senior student, 55.4% did not have any intention to change their profession, 81.2% wanted to work as nurses, and 82.2% were planning career advancement in nursing of the students, 34.7% and 43.6% were found to experience burnout, before and after the nursing internship, respectively (p < 0.05). When the students' mean pre-test and post-test scores on the nursing professional commitment scale were compared, a significant difference was found between mean scores on the total score and "maintaining membership" subscale (p < 0.05). This study revealed that after the nursing internship, burnout and professional commitment levels of the students increased. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Workplace empowerment and organizational commitment among nurses working at the Main University Hospital, Alexandria, Egypt.

    PubMed

    Ibrahem, Samaa Z; Elhoseeny, Taghareed; Mahmoud, Rasha A

    2013-08-01

    High-quality patient care depends on a nursing workforce that is empowered to provide care according to professional nursing standards. Numerous studies have established positive relationships between empowerment and important nursing outcomes such as work effectiveness, job satisfaction, and organizational commitment. A cross-sectional study design was used to assess the relationships between structural and psychological empowerment and their effects on hospital nurses' organizational commitment at the Main University Hospital in Alexandria governorate. The total number of nurses who participated in the study was 150 nurses, and four interview questionnaires were used to measure the study variables. The mean score percentage was higher for overall psychological empowerment (68.75%) than for overall structural empowerment (46.25%). There was a significant direct intermediate correlation between nurses' perceptions of overall structural and psychological work empowerment and their overall organizational commitment. There was no significant relationship between structural and psychological empowerment, organizational commitment and sociodemographic characteristics of nurses except for the overall organizational commitment with age (r=0.260), overall structural empowerment in the working department (P=0.031), and overall organizational commitment with nursing experience (significance=0.025). Overall psychological empowerment achieved a higher mean score percentage compared with overall structural empowerment. Changing workplace structures is within the mandate of nurses' managers in their roles as advocates for and facilitators of high-quality care. The most significant opportunity for improvement is in the area of formal power, including flexibility, adaptability, creativity associated with discretionary decision-making, visibility, and centrality to organizational purpose and goals.

  10. Radiation protocols determine acute graft-versus-host disease incidence after allogeneic bone marrow transplantation in murine models.

    PubMed

    Schwarte, Sebastian; Bremer, Michael; Fruehauf, Joerg; Sorge, Yanina; Skubich, Susanne; Hoffmann, Matthias W

    2007-09-01

    Effects of radiation sources used for total body irradiation (TBI) on Graft-versus-Host Disease (GvHD) induction were examined. In a T cell receptor (TCR) transgenic mouse model, single fraction TBI was performed with different radiation devices ((60)Cobalt; (137)Cesium; 6 MV linear accelerator), dose rates (0.85; 1.5; 2.9; 5 Gy/min) and total doses before allogeneic bone marrow transplantation (BMT). Recipients were observed for 120 days. Different tissues were examined histologically. Acute GvHD was induced by a dose rate of 0.85 Gy/min ((60)Cobalt) and a total dose of 9 Gy and injection of 5 x 10(5) lymph node cells plus 5 x 10(6) bone marrow cells. Similar results were obtained using 6 MV linear accelerator- (linac-) photons with a dose rate of 1.5 Gy/min and 0.85 Gy/min, a total dose of 9.5 Gy and injection of same cell numbers. TBI with (137)Cesium (dose rate: 2.5 Gy/min) did not lead reproducibly to lethal acute GvHD. Experimental TBI in murine models may induce different immunological responses, depending on total energy, total single dose and dose rate. GvHD might also be induced by TBI with low dose rates.

  11. Real-time colour pictorial radiation monitoring during coronary angiography: effect on patient peak skin and total dose during coronary angiography.

    PubMed

    Wilson, Sharon M; Prasan, Ananth M; Virdi, Amy; Lassere, Marissa; Ison, Glenn; Ramsay, David R; Weaver, James C

    2016-10-10

    The aim of this study was to evaluate whether a real-time (RT) colour pictorial radiation dose monitoring system reduces patient skin and total radiation dose during coronary angiography and intervention. Patient demographics, procedural variables and radiation parameters were recorded before and after institution of the RT skin dose recording system. Peak skin dose as well as traditionally available measures of procedural radiation dose were compared. A total of 1,077 consecutive patients underwent coronary angiography, of whom 460 also had PCI. Institution of the RT skin dose recording system resulted in a 22% reduction in peak skin dose after accounting for confounding variables. Radiation dose reduction was most pronounced in those having PCI but was also seen over a range of subgroups including those with prior coronary artery bypass surgery, high BMI, and with radial arterial access. This was associated with a significant reduction in the number of patients placed at risk of skin damage. Similar reductions in parameters reflective of total radiation dose were also demonstrated after institution of RT radiation monitoring. Institution of an RT skin dose recording reduced patient peak skin and total radiation dose during coronary angiography and intervention. Consideration should be given to widespread adoption of this technology.

  12. Defense Threat Reduction Agency > Careers > Onboarding

    Science.gov Websites

    , click HERE. Let's Get Started Our values allow personnel to achieve their commitment to total customer satisfaction by meeting and anticipating customer needs. INTEGRITY SERVICE EXCELLENCE INNOVATION TEAMWORK

  13. Requirements for radiation emergency urine bioassay techniques for the public and first responders.

    PubMed

    Li, Chunsheng; Vlahovich, Slavica; Dai, Xiongxin; Richardson, Richard B; Daka, Joseph N; Kramer, Gary H

    2010-11-01

    Following a radiation emergency, the affected public and the first responders may need to be quickly assessed for internal contamination by the radionuclides involved. Urine bioassay is one of the most commonly used methods for assessing radionuclide intake and radiation dose. This paper attempts to derive the sensitivity requirements (from inhalation exposure) for the urine bioassay techniques for the top 10 high-risk radionuclides that might be used in a terrorist attack. The requirements are based on a proposed reference dose to adults of 0.1 Sv (CED, committed effective dose). In addition, requirements related to sample turnaround time and field deployability of the assay techniques are also discussed. A review of currently available assay techniques summarized in this paper reveals that method development for ²⁴¹Am, ²²⁶Ra, ²³⁸Pu, and ⁹⁰Sr urine bioassay is needed.

  14. G-CSF-primed BM for allogeneic SCT: revisited.

    PubMed

    Pessach, I; Resnick, I; Shimoni, A; Nagler, A

    2015-07-01

    G-SCF-mobilized PBSC (GPB) grafts have a higher cell dose and somewhat more committed progenitor cells than steady-state BM (SBM), resulting in faster engraftment and faster immunological reconstitution. On the other hand, transplant related mortality (TRM), disease-free survival (DFS) and overall survival (OS) are similar both for PB and for BM. In contrast to SBM, G-CSF-primed BM (GBM) grafts stimulate HSC proliferation, increasing cell dose and thus resulting in faster engraftment because of higher cell dose infused, or because of treatment with G-CSF. Furthermore, GBM may induce tolerance and functional modulations in donor hematopoiesis and immunity, further reducing GVHD incidence, which is already lower with SBM compared with GPB grafts. Overall, a growing body of clinical evidence suggests that GBM transplants may share the advantages of GPB transplantations, without the associated increased risk of GVHD, and might be an attractive graft source for allogeneic SCTs.

  15. Employee satisfaction: an integral component of total quality.

    PubMed

    Gvazdinskas, L C; Maffetone, M A

    1995-01-01

    As part of the Total Quality Management process, the leadership of Rush Medical Laboratories, with a staff of 400, made an initial commitment to focus on their own employees as the most important customers. Only after the employees' development, their help, their support, and their empowerment could Rush Medical Laboratories make the improvements in customer relationships and obtain the operations improvement, cost savings, and productivity necessary to maintain a competitive edge. This article outlines the numerous employee initiatives that have resulted from this commitment. All of these initiatives were successful at some point during the 5 or more years since the incorporation of TQM within Rush Medical Laboratories. In the spirit of continuous improvement, some have been modified or discontinued and replaced by others. This article provides an overview of the many improvements that are possible when employees are provided a forum in which to voice their needs, and it challenges the management and employees of all laboratories to focus on this vital component of total quality.

  16. γ-H2AX Kinetic Profile in Mouse Lymphocytes Exposed to the Internal Emitters Cesium-137 and Strontium-90

    PubMed Central

    Turner, Helen C.; Shuryak, Igor; Weber, Waylon; Doyle-Eisele, Melanie; Melo, Dunstana; Guilmette, Raymond; Amundson, Sally A.; Brenner, David J.

    2015-01-01

    In the event of a dirty bomb scenario or an industrial nuclear accident, a significant dose of volatile radionuclides such as 137Cs and 90Sr may be dispersed into the atmosphere as a component of fallout and inhaled or ingested by hundreds and thousands of people. To study the effects of prolonged exposure to ingested radionuclides, we have performed long-term (30 day) internal-emitter mouse irradiations using soluble-injected 137CsCl and 90SrCl2 radioisotopes. The effect of ionizing radiation on the induction and repair of DNA double strand breaks (DSBs) in peripheral mouse lymphocytes in vivo was determined using the γ-H2AX biodosimetry marker. Using a serial sacrifice experimental design, whole-body radiation absorbed doses for 137Cs (0 to 10 Gy) and 90Sr (0 to 49 Gy) were delivered over 30 days following exposure to each radionuclide. The committed absorbed doses of the two internal emitters as a function of time post exposure were calculated based on their retention parameters and their derived dose coefficients for each specific sacrifice time. In order to measure the kinetic profile for γ-H2AX, peripheral blood samples were drawn at 5 specific timed dose points over the 30-day study period and the total γ-H2AX nuclear fluorescence per lymphocyte was determined using image analysis software. A key finding was that a significant γ-H2AX signal was observed in vivo several weeks after a single radionuclide exposure. A mechanistically-motivated model was used to analyze the temporal kinetics of γ-H2AX fluorescence. Exposure to either radionuclide showed two peaks of γ-H2AX: one within the first week, which may represent the death of mature, differentiated lymphocytes, and the second at approximately three weeks, which may represent the production of new lymphocytes from damaged progenitor cells. The complexity of the observed responses to internal irradiation is likely caused by the interplay between continual production and repair of DNA damage, cell cycle effects and apoptosis. PMID:26618801

  17. γ-H2AX Kinetic Profile in Mouse Lymphocytes Exposed to the Internal Emitters Cesium-137 and Strontium-90.

    PubMed

    Turner, Helen C; Shuryak, Igor; Weber, Waylon; Doyle-Eisele, Melanie; Melo, Dunstana; Guilmette, Raymond; Amundson, Sally A; Brenner, David J

    2015-01-01

    In the event of a dirty bomb scenario or an industrial nuclear accident, a significant dose of volatile radionuclides such as 137Cs and 90Sr may be dispersed into the atmosphere as a component of fallout and inhaled or ingested by hundreds and thousands of people. To study the effects of prolonged exposure to ingested radionuclides, we have performed long-term (30 day) internal-emitter mouse irradiations using soluble-injected 137CsCl and 90SrCl2 radioisotopes. The effect of ionizing radiation on the induction and repair of DNA double strand breaks (DSBs) in peripheral mouse lymphocytes in vivo was determined using the γ-H2AX biodosimetry marker. Using a serial sacrifice experimental design, whole-body radiation absorbed doses for 137Cs (0 to 10 Gy) and 90Sr (0 to 49 Gy) were delivered over 30 days following exposure to each radionuclide. The committed absorbed doses of the two internal emitters as a function of time post exposure were calculated based on their retention parameters and their derived dose coefficients for each specific sacrifice time. In order to measure the kinetic profile for γ-H2AX, peripheral blood samples were drawn at 5 specific timed dose points over the 30-day study period and the total γ-H2AX nuclear fluorescence per lymphocyte was determined using image analysis software. A key finding was that a significant γ-H2AX signal was observed in vivo several weeks after a single radionuclide exposure. A mechanistically-motivated model was used to analyze the temporal kinetics of γ-H2AX fluorescence. Exposure to either radionuclide showed two peaks of γ-H2AX: one within the first week, which may represent the death of mature, differentiated lymphocytes, and the second at approximately three weeks, which may represent the production of new lymphocytes from damaged progenitor cells. The complexity of the observed responses to internal irradiation is likely caused by the interplay between continual production and repair of DNA damage, cell cycle effects and apoptosis.

  18. Use of Transportable Radiation Detection Instruments to Assess Internal Contamination from Intakes of Radionuclides Part II: Calibration Factors and ICAT Computer Program.

    PubMed

    Anigstein, Robert; Olsher, Richard H; Loomis, Donald A; Ansari, Armin

    2016-12-01

    The detonation of a radiological dispersion device or other radiological incidents could result in widespread releases of radioactive materials and intakes of radionuclides by affected individuals. Transportable radiation monitoring instruments could be used to measure radiation from gamma-emitting radionuclides in the body for triaging individuals and assigning priorities to their bioassay samples for in vitro assessments. The present study derived sets of calibration factors for four instruments: the Ludlum Model 44-2 gamma scintillator, a survey meter containing a 2.54 × 2.54-cm NaI(Tl) crystal; the Captus 3000 thyroid uptake probe, which contains a 5.08 × 5.08-cm NaI(Tl) crystal; the Transportable Portal Monitor Model TPM-903B, which contains two 3.81 × 7.62 × 182.9-cm polyvinyltoluene plastic scintillators; and a generic instrument, such as an ionization chamber, that measures exposure rates. The calibration factors enable these instruments to be used for assessing inhaled or ingested intakes of any of four radionuclides: Co, I, Cs, and Ir. The derivations used biokinetic models embodied in the DCAL computer software system developed by the Oak Ridge National Laboratory and Monte Carlo simulations using the MCNPX radiation transport code. The three physical instruments were represented by MCNP models that were developed previously. The affected individuals comprised children of five ages who were represented by the revised Oak Ridge National Laboratory pediatric phantoms, and adult men and adult women represented by the Adult Reference Computational Phantoms described in Publication 110 of the International Commission on Radiological Protection. These calibration factors can be used to calculate intakes; the intakes can be converted to committed doses by the use of tabulated dose coefficients. These calibration factors also constitute input data to the ICAT computer program, an interactive Microsoft Windows-based software package that estimates intakes of radionuclides and cumulative and committed effective doses, based on measurements made with these instruments. This program constitutes a convenient tool for assessing intakes and doses without consulting tabulated calibration factors and dose coefficients.

  19. USE OF TRANSPORTABLE RADIATION DETECTION INSTRUMENTS TO ASSESS INTERNAL CONTAMINATION FROM INTAKES OF RADIONUCLIDES PART II: CALIBRATION FACTORS AND ICAT COMPUTER PROGRAM

    PubMed Central

    Anigstein, Robert; Olsher, Richard H.; Loomis, Donald A.; Ansari, Armin

    2017-01-01

    The detonation of a radiological dispersion device or other radiological incidents could result in widespread releases of radioactive materials and intakes of radionuclides by affected individuals. Transportable radiation monitoring instruments could be used to measure radiation from gamma-emitting radionuclides in the body for triaging individuals and assigning priorities to their bioassay samples for in vitro assessments. The present study derived sets of calibration factors for four instruments: the Ludlum Model 44-2 gamma scintillator, a survey meter containing a 2.54 × 2.54-cm NaI(Tl) crystal; the Captus 3000 thyroid uptake probe, which contains a 5.08 × 5.08-cm NaI(Tl) crystal; the Transportable Portal Monitor Model TPM-903B, which contains two 3.81 × 7.62 × 182.9-cm polyvinyltoluene plastic scintillators; and a generic instrument, such as an ionization chamber, that measures exposure rates. The calibration factors enable these instruments to be used for assessing inhaled or ingested intakes of any of four radionuclides: 60Co, 131I, 137Cs, and 192Ir. The derivations used biokinetic models embodied in the DCAL computer software system developed by the Oak Ridge National Laboratory and Monte Carlo simulations using the MCNPX radiation transport code. The three physical instruments were represented by MCNP models that were developed previously. The affected individuals comprised children of five ages who were represented by the revised Oak Ridge National Laboratory pediatric phantoms, and adult men and adult women represented by the Adult Reference Computational Phantoms described in Publication 110 of the International Commission on Radiological Protection. These calibration factors can be used to calculate intakes; the intakes can be converted to committed doses by the use of tabulated dose coefficients. These calibration factors also constitute input data to the ICAT computer program, an interactive Microsoft Windows-based software package that estimates intakes of radionuclides and cumulative and committed effective doses, based on measurements made with these instruments. This program constitutes a convenient tool for assessing intakes and doses without consulting tabulated calibration factors and dose coefficients. PMID:27798478

  20. What We Offer | FNLCR Staging

    Cancer.gov

    Opportunities We recognize that employee benefit programs are an important part of the total compensation package, and are committed to providing you with comprehensive benefit options. The Frederick National Lab's prime contractor, Leidos Biomedi

  1. Religiousness, religious coping methods and distress level among psychiatric patients in Malaysia.

    PubMed

    Nurasikin, M S; Khatijah, L A; Aini, A; Ramli, M; Aida, S A; Zainal, N Z; Ng, C G

    2013-06-01

    Patients having psychiatric diagnoses often experience high level of distress. Religiousness is often used by them as part of their coping mechanism and problem-solving strategies. To determine the level of religious commitment and coping methods in psychiatric patients and its relationship with distress level. Religious commitment and coping patterns were measured with the Duke University Religious Index (DUREL) and Brief RCOPE, respectively. Psychopathology was assessed using the Brief Psychiatric Rating Scale (BPRS) and distress level was assessed with the Depressive, Anxiety and Stress Scale (DASS). Social support and experiences of recent threatening events were measured with the Multidimensional Scale of Perceived Social Support (MSPSS) and Life Threatening Events (LTE). A total of 228 patients were included in this study with a mean age of 40.2 years. The majority were male, Malay, Muslim, single and with psychotic disorder. The subjects had a high level of religious commitment and had used more positive coping methods. Negative religious coping, psychiatric symptoms and diagnosis of anxiety disorder or major depression were significantly associated with high distress level. Higher religious commitment was significantly associated with lower distress (p < .05). Psychiatric patients were religiously committed and used more positive religious coping methods. Practices of negative religious coping, severe psychiatric symptoms and anxiety/depression were associated with higher distress.

  2. Absorbed dose thresholds and absorbed dose rate limitations for studies of electron radiation effects on polyetherimides

    NASA Technical Reports Server (NTRS)

    Long, Edward R., Jr.; Long, Sheila Ann T.; Gray, Stephanie L.; Collins, William D.

    1989-01-01

    The threshold values of total absorbed dose for causing changes in tensile properties of a polyetherimide film and the limitations of the absorbed dose rate for accelerated-exposure evaluation of the effects of electron radiation in geosynchronous orbit were studied. Total absorbed doses from 1 kGy to 100 MGy and absorbed dose rates from 0.01 MGy/hr to 100 MGy/hr were investigated, where 1 Gy equals 100 rads. Total doses less than 2.5 MGy did not significantly change the tensile properties of the film whereas doses higher than 2.5 MGy significantly reduced elongation-to-failure. There was no measurable effect of the dose rate on the tensile properties for accelerated electron exposures.

  3. Incorporating Total Quality Management in an Engineering Design Course. Report 5-1993.

    ERIC Educational Resources Information Center

    Wilczynski, V.; And Others

    One definition of creativity is the conviction that each and every existing idea can be improved. It is proposed that creativity in an engineering design process can be encouraged by the adoption of Total Quality Management (TQM) methods based on a commitment to continuous improvement. This paper addresses the introduction and application of TQM…

  4. Punishments adolescents find justified: an examination of altitudes toward delinquency.

    PubMed

    Landsheer, J A; Hart, H T

    2000-01-01

    The purpose of this study was to examine adolescents' attitudes toward delinquency, specifically the degree to which they find norm violations acceptable in various circumstances. A total of 1,914 Dutch youths participated: 1,046 reported having committed no crimes in the past year, 578 reported having committed only nonviolent offenses, and 290 reported having committed both violent and nonviolent offenses. It was hypothesized that, in general, delinquents would prescribe less severe punishments for deviant behavior, irrespective of the circumstances. This hypothesis was rejected. It was found, however, that violent delinquents were significantly more tolerant of violent behavior as compared with nondelinquents, with one important exception: when injury was inflicted on someone they knew, they were as little inclined to excuse the perpetrator as were nondelinquents. Violent delinquents discriminated most strongly between friends and strangers as both victims and perpetrators.

  5. Impact of culture on commitment, satisfaction, and extra-role behaviors among Canadian ER physicians.

    PubMed

    Williams, E S; Rondeau, K V; Francescutti, L H

    2007-01-01

    The purpose of this paper is to explore the impact of hospital emergency department culture on the job satisfaction, patient commitment, and extra-role performance of Canadian emergency physicians. The conceptual model related four cultural archetypes from the competing valued model to the three outcome variables. In total, 428 Canadian emergency physicians responded to a national survey. The conceptual model was tested via structural equation modeling via LISREL 8. Culture had a relatively weak impact on the outcomes. Human resources culture related positively to job satisfaction while bureaucratic culture related positively to patient commitment. Patient commitment, but not job satisfaction strongly and positively related to extra-role behavior. A direct relationship between entrepreneurial culture and extra-role behavior emerged from an extended analysis. Organizational culture seems to have more distal relationships with outcome variables and its influence is likely to be mediated by more proximal workplace variables. Of value by showing that a key modern leadership challenge is to create the kind of work culture that can become a source of competitive advantage through generating particular organizational outcomes valued by stakeholders.

  6. National and Gender Measurement Invariance of the Utrecht-Management of Identity Commitments Scale (U-MICS): A 10-Nation Study With University Students.

    PubMed

    Crocetti, Elisabetta; Cieciuch, Jan; Gao, Cheng-Hai; Klimstra, Theo; Lin, Ching-Ling; Matos, Paula Mena; Morsünbül, Ümit; Negru, Oana; Sugimura, Kazumi; Zimmermann, Grégoire; Meeus, Wim

    2015-12-01

    The purpose of this study was to examine the psychometric properties of the Utrecht-Management of Identity Commitments Scale (U-MICS), a self-report measure aimed at assessing identity processes of commitment, in-depth exploration, and reconsideration of commitment. We tested its factor structure in university students from a large array of cultural contexts, including 10 nations located in Europe (i.e., Italy, the Netherlands, Poland, Portugal, Romania, and Switzerland), Middle East (i.e., Turkey), and Asia (i.e., China, Japan, and Taiwan). Furthermore, we tested national and gender measurement invariance. Participants were 6,118 (63.2% females) university students aged from 18 to 25 years (Mage = 20.91 years). Results indicated that the three-factor structure of the U-MICS fitted well in the total sample, in each national group, and in gender groups. Furthermore, national and gender measurement invariance were established. Thus, the U-MICS can be fruitfully applied to study identity in university students from various Western and non-Western contexts. © The Author(s) 2015.

  7. Religious commitment, attitudes toward suicide, and suicidal behaviors among college students of different ethnic and religious groups in Malaysia.

    PubMed

    Foo, Xiang Yi; Alwi, Muhd Najib Mohd; Ismail, Siti Irma Fadhillah; Ibrahim, Normala; Osman, Zubaidah Jamil

    2014-06-01

    The variation in suicide patterns across ethnic groups with different religious background is a puzzling social phenomenon. This study sought to examine the impact of religious commitment and attitudes toward suicide on suicidal behaviors of college students across major ethnic and religious groups in a multicultural society of Malaysia. A total of 139 college students completed Religious Commitment Inventory-10, Attitudes Toward Suicide Scale, and Suicidal Behavior Questionnaire-Revised. Findings showed significant discrepancies in attitudes toward suicide, but not suicidal behaviors across ethnic and religious groups. Suicide acceptance significantly affected suicidal behaviors as well. Although religious commitment is not associated with suicidal behaviors, its deviation is reflected in students' acceptance of suicide. Additionally, college students' suicide risk, lifetime, and recent suicide ideation, as well as their likelihood of future suicide attempt can be associated with their acceptance of suicide. The influence of attitudes toward suicide and religion, therefore, should be taken into consideration while implementing suicide prevention programs as it helps shape the norms about suicide among youths.

  8. The Impact of Organizational Commitment and Nursing Organizational Culture on Job Satisfaction in Korean American Registered Nurses.

    PubMed

    Kim, Young Im; Geun, Hyo Geun; Choi, SookJa; Lee, Young Sil

    2016-09-01

    This study aimed to describe the perceived level of organizational commitment and organizational culture of Korean American Registered Nurses (KARNs) and to investigate predictors of job satisfaction. A total of 163 KARNs working in U.S. hospitals responded to a Web survey. Descriptive analysis, t test, analysis of variance, and stepwise regressions were used for data analysis. KARNs reported moderate levels of job satisfaction (3.5 ± 0.58). Job satisfaction was positively correlated with both organizational commitment (r = .85, p < .001) and culture (r = .66, p < .001). KARNs who were aged ≥50, married, hospital-employed, had longer nursing experience, and experienced turnover at least once were more likely to report higher job satisfaction compared with other nurses. Organizational commitment, culture, marital status, and workplace were significant predictors of and explained 76.8% of the variance in job satisfaction. This study provides evidence to help nursing managers and health policy makers develop educational programs aimed at enhancing job satisfaction and retention of KARNs. © The Author(s) 2016.

  9. Maximum dose rate is a determinant of hypothyroidism after 131I therapy of Graves' disease but the total thyroid absorbed dose is not.

    PubMed

    Krohn, Thomas; Hänscheid, Heribert; Müller, Berthold; Behrendt, Florian F; Heinzel, Alexander; Mottaghy, Felix M; Verburg, Frederik A

    2014-11-01

    The determinants of successful (131)I therapy of Graves' disease (GD) are unclear. To relate dosimetry parameters to outcome of therapy to identify significant determinants eu- and/or hypothyroidism after (131)I therapy in patients with GD. A retrospective study in which 206 Patients with GD treated in University Hospital between November 1999 and January 2011. All received (131)I therapy aiming at a total absorbed dose to the thyroid of 250 Gy based on pre-therapeutic dosimetry. Post-therapy dosimetric thyroid measurements were performed twice daily until discharge. From these measurements, thyroid (131)I half-life, the total thyroid absorbed dose, and the maximum dose rate after (131)I administration were calculated. In all, 48.5% of patients were hypothyroid and 28.6% of patients were euthyroid after (131)I therapy. In univariate analysis, nonhyperthyroid and hyperthyroid patients only differed by sex. A lower thyroid mass, a higher activity per gram thyroid tissue, a shorter effective thyroidal (131)I half-life, and a higher maximum dose rate, but not the total thyroid absorbed dose, were significantly associated with hypothyroidism. In multivariate analysis, the maximum dose rate remained the only significant determinant of hypothyroidism (P < .001). Maximum dose rates of 2.2 Gy/h and higher were associated with a 100% hypothyroidism rate. Not the total thyroid absorbed dose, but the maximum dose rate is a determinant of successfully achieving hypothyroidism in Graves' disease. Dosimetric concepts aiming at a specific total thyroid absorbed dose will therefore require reconsideration if our data are confirmed prospectively.

  10. Revisiting the impact of job satisfaction and organizational commitment on nurse turnover intention: an individual differences analysis.

    PubMed

    De Gieter, Sara; Hofmans, Joeri; Pepermans, Roland

    2011-12-01

    Nurse turnover is an important contributing factor to the worldwide nursing shortage. Many studies have examined the antecedents of nurse turnover to gain a better understanding of the problem and help hospitals reduce their turnover rates. However, an important shortcoming of this research stream is its exclusive focus on explaining turnover behavior of the "average nurse", thereby disregarding individual differences between nurses and groups of nurses. To examine individual differences in the relationships between two crucial turnover antecedents - job satisfaction and organizational commitment - and nurse turnover intention. A sample of 287 nurses working for a variety of Belgian hospitals participated in the study. A survey method was used to collect quantitative data, which were analyzed through standard multiple linear regression, mixture regression models and t-tests. In the total sample of hospital nurses, both job satisfaction and organizational commitment significantly predicted nurse turnover intention. However, subsequent individual differences analyses revealed the existence of two subgroups of nurses. In the satisfaction focused group, only job satisfaction was found to predict nurse turnover intention, whereas in the satisfaction and commitment focused group both job satisfaction and organizational commitment were related to turnover intention. Furthermore, nurses in the latter group displayed stronger turnover intention, were significantly younger and had less job tenure and organizational tenure than nurses in the satisfaction focused group. The debate on the antecedents of nurse turnover still continues, as the existing models fail to fully grasp nurse turnover. The present study identifies individual differences in nurse turnover antecedents among groups of nurses as a possible reason for the absence of one comprehensive turnover model that holds for the general nursing population. Further studies are needed in order to capture the total impact of the underlying individual differences in nurse turnover antecedents. 2011 Elsevier Ltd. All rights reserved.

  11. Nudging guideline-concordant antibiotic prescribing: a randomized clinical trial.

    PubMed

    Meeker, Daniella; Knight, Tara K; Friedberg, Mark W; Linder, Jeffrey A; Goldstein, Noah J; Fox, Craig R; Rothfeld, Alan; Diaz, Guillermo; Doctor, Jason N

    2014-03-01

    "Nudges" that influence decision making through subtle cognitive mechanisms have been shown to be highly effective in a wide range of applications, but there have been few experiments to improve clinical practice. To investigate the use of a behavioral "nudge" based on the principle of public commitment in encouraging the judicious use of antibiotics for acute respiratory infections (ARIs). Randomized clinical trial in 5 outpatient primary care clinics. A total of 954 adults had ARI visits during the study timeframe: 449 patients were treated by clinicians randomized to the posted commitment letter (335 in the baseline period, 114 in the intervention period); 505 patients were treated by clinicians randomized to standard practice control (384 baseline, 121 intervention). The intervention consisted of displaying poster-sized commitment letters in examination rooms for 12 weeks. These letters, featuring clinician photographs and signatures, stated their commitment to avoid inappropriate antibiotic prescribing for ARIs. Antibiotic prescribing rates for antibiotic-inappropriate ARI diagnoses in baseline and intervention periods, adjusted for patient age, sex, and insurance status. Baseline rates were 43.5% and 42.8% for control and poster, respectively. During the intervention period, inappropriate prescribing rates increased to 52.7% for controls but decreased to 33.7% in the posted commitment letter condition. Controlling for baseline prescribing rates, we found that the posted commitment letter resulted in a 19.7 absolute percentage reduction in inappropriate antibiotic prescribing rate relative to control (P = .02). There was no evidence of diagnostic coding shift, and rates of appropriate antibiotic prescriptions did not diminish over time. Displaying poster-sized commitment letters in examination rooms decreased inappropriate antibiotic prescribing for ARIs. The effect of this simple, low-cost intervention is comparable in magnitude to costlier, more intensive quality-improvement efforts. clinicaltrials.gov identifier: NCT01767064.

  12. The Incorporation of Radionuclides After Wounding by a “Dirty Bomb”: The Impact of Time for Decorporation Efficacy and a Model for Cases of Disseminated Fragmentation Wounds

    PubMed Central

    Rump, Alexis; Stricklin, Daniela; Lamkowski, Andreas; Eder, Stefan; Abend, Michael; Port, Matthias

    2017-01-01

    Objective: In the case of a terrorist attack by a “dirty bomb” there is a risk of internal contamination with radionuclides through inhalation and wounds. We studied the efficacy of a decorporation treatment depending on the initiation time and duration. Approach: Based on biokinetic models, we simulated the impact of different diethylenetriaminepentaacetic acid treatments on the committed effective dose after the incorporation of plutonium-239. Results: For the same level of radioactivity, the dose was higher after the fast absorption from the wound than after a slow invasion following inhalation. The impact of the treatment initiation time was particularly important in the case of the internal contamination through the wound. Ending the treatment at an early point in time was followed by an augmentation of radioactivity in the blood compartment, reflecting insufficient treatment duration. Treatment efficacy increased only marginally if extended over 90 days. Innovation and Conclusion: For plutonium-239, the committed effective dose and the impact of the treatment initiation time on therapeutic efficacy predominantly depend on the speed of invasion, i.e., the pathway and the physicochemical properties of the compounds involved. Thus, it is prudent to start decorporation therapy as soon as possible, as a loss of efficacy resulting from a delay in treatment initiation cannot be compensated later on. In the case of plutonium-239 incorporation, the treatment must be continued for several months. Multiple fragmentation wounds might be aggregated to a single wound model suited for internal dosimetry calculations by using the “rule of nine.” PMID:28116223

  13. Committed effective dose from naturally occuring radionuclides in shellfish

    NASA Astrophysics Data System (ADS)

    Khandaker, Mayeen Uddin; Wahib, Norfadira Binti; Amin, Yusoff Mohd.; Bradley, D. A.

    2013-07-01

    Recognizing their importance in the average Malaysian daily diet, the radioactivity concentrations in mollusc- and crustacean-based food have been determined for key naturally occuring radionuclides. Fresh samples collected from various maritime locations around peninsular Malaysia have been processed using standard procedures; the radionuclide concentrations being determined using an HPGe γ-ray spectrometer. For molluscs, assuming secular equilibrium, the range of activities of 238U (226Ra), 232Th (228Ra) and 40K were found to be 3.28±0.35 to 5.34±0.52, 1.20±0.21 to 2.44±0.21 and 118±6 to 281±14 Bq kg-1 dry weight, respectively. The respective values for crustaceans were 3.02±0.57 to 4.70±0.52, 1.38±0.21 to 2.40±0.35 and 216±11 to 316±15 Bq kg-1. The estimated average daily intake of radioactivity from consumption of molluscs are 0.37 Bq kg-1 for 238U (226Ra), 0.16 Bq kg-1 for 232Th (228Ra) and 18 Bq kg-1 for 40K; the respective daily intake values from crustaceans are 0.36 Bq kg-1, 0.16 Bq kg-1 and 23 Bq kg-1. Associated annual committed effective doses from molluscs are estimated to be in the range 21.3 to 34.7 μSv for 226Ra, 19.3 to 39.1 μSv for 228Ra and 17.0 to 40.4 μSv for 40K. For crustaceans, the respective dose ranges are 19.6 to 30.5 μSv, 22.0 to 38.4 μSv and 31.1 to 45.5 μSv, being some several times world average values.

  14. What We Offer | Frederick National Laboratory for Cancer Research

    Cancer.gov

    Opportunities We recognize that employee benefit programs are an important part of the total compensation package, and are committed to providing you with comprehensive benefit options. The Frederick National Laboratory's prime contractor, Leidos

  15. Total body irradiation, toward optimal individual delivery: dose evaluation with metal oxide field effect transistors, thermoluminescence detectors, and a treatment planning system.

    PubMed

    Bloemen-van Gurp, Esther J; Mijnheer, Ben J; Verschueren, Tom A M; Lambin, Philippe

    2007-11-15

    To predict the three-dimensional dose distribution of our total body irradiation technique, using a commercial treatment planning system (TPS). In vivo dosimetry, using metal oxide field effect transistors (MOSFETs) and thermoluminescence detectors (TLDs), was used to verify the calculated dose distributions. A total body computed tomography scan was performed and loaded into our TPS, and a three-dimensional-dose distribution was generated. In vivo dosimetry was performed at five locations on the patient. Entrance and exit dose values were converted to midline doses using conversion factors, previously determined with phantom measurements. The TPS-predicted dose values were compared with the MOSFET and TLD in vivo dose values. The MOSFET and TLD dose values agreed within 3.0% and the MOSFET and TPS data within 0.5%. The convolution algorithm of the TPS, which is routinely applied in the clinic, overestimated the dose in the lung region. Using a superposition algorithm reduced the calculated lung dose by approximately 3%. The dose inhomogeneity, as predicted by the TPS, can be reduced using a simple intensity-modulated radiotherapy technique. The use of a TPS to calculate the dose distributions in individual patients during total body irradiation is strongly recommended. Using a TPS gives good insight of the over- and underdosage in a patient and the influence of patient positioning on dose homogeneity. MOSFETs are suitable for in vivo dosimetry purposes during total body irradiation, when using appropriate conversion factors. The MOSFET, TLD, and TPS results agreed within acceptable margins.

  16. Comparison between in vivo dosimetry and barium contrast technique for prediction of rectal complications in high-dose-rate intracavitary radiotherapy in cervix cancer patients.

    PubMed

    Huh, Seung Jae; Lim, Do Hoon; Ahn, Yong Chan; Lee, Jeong Eun; Kang, Min Kyu; Shin, Seong Soo; Shin, Kyung Hwan; Kim, Bokyung; Park, Won; Han, Youngyih

    2003-03-01

    To investigate the correlation between late rectal complications and rectal dose in cervix cancer patients treated with high-dose-rate intracavitary radiotherapy (HDR ICR) and to analyze factors reducing rectal complications. A total of 136 patients with cervix cancer who were treated with external beam radiotherapy (EBRT) and HDR ICR from 1995 to 1999 were retrospectively analyzed. Radiotherapy (RT) consisted of EBRT plus HDR ICR. The median EBRT dose was 50.4 Gy, and midline block was done after 30-50 Gy of EBRT. A total of six fractions of HDR ICR with 4 Gy fraction size each were applied twice per week to the A point. The rectal dose was calculated at the rectal reference point using the barium contrast criteria. In vivo measurement of the rectal dose was performed with thermoluminescent dosimeter (TLD) during HDR ICR. The median follow-up period was 26 months (range 6-60 months). A total of 16 patients (12%) experienced rectal bleeding, which occurred 4-33 months (median 11 months) after the completion of RT. The calculated rectal doses did not differ in patients with rectal bleeding and those without, but the measured rectal doses were higher in affected patients. The differences of the measured ICR fractional rectal dose, ICR total rectal dose, and total rectal biologically equivalent dose (BED) were statistically significant. When the measured ICR total rectal dose exceeded 16 Gy, the ratio of the measured rectal dose to A point dose was > 70%; when the measured rectal BED exceeded 110 Gy(3), a high possibility of late rectal complications could be found. In vivo dosimetry using TLD during HDR ICR was a good predictor of late rectal complications. Hence, if data from in vivo dosimetry shows any possibility of rectal bleeding, efforts should be made to reduce the rectal dose.

  17. [Suicidal drug overdose while receiving palliative home care: a case report].

    PubMed

    Mosich, Veronika; Müller-Busch, H Christof

    2014-05-01

    Suicidal thoughts are a common phenomenon in palliative care which can be seen in around 10% of the patients. There is very little knowledge about attempted and committed suicide. This article is a case report about a patient with lung cancer in a terminal state of illness who ingested drugs in a toxic dose while receiving palliative home care. This article deals with ethical issues in medical treatment and various ways of decision-making.

  18. Comparison of alcohol impairment of behavioral and attentional inhibition.

    PubMed

    Weafer, Jessica; Fillmore, Mark T

    2012-11-01

    Despite the wealth of studies demonstrating the impairing effects of alcohol on behavioral inhibition, less is known regarding effects of the drug on attentional inhibition (i.e., the ability to ignore distracting stimuli in the environment in order to focus attention on relevant information). The current study examined alcohol impairment of both behavioral and attentional inhibition, as well as potential associations between the two mechanisms of inhibitory control. Men (n=27) and women (n=21) performed a measure of behavioral inhibition (cued go/no-go task) and a measure of attentional inhibition (delayed ocular return task) following three doses of alcohol: 0.65 g/kg, 0.45 g/kg, and 0.0 g/kg (placebo). Alcohol impaired both behavioral and attentional inhibition relative to placebo; however, correlational analyses revealed no associations between measures of behavioral and attentional inhibition following any dose. Additionally, men committed more inhibitory failures on the behavioral inhibition task, whereas women committed more inhibitory failures on the attentional inhibition task. These findings suggest that behavioral and attentional inhibition are equally sensitive to the impairing effects of alcohol, yet represent distinct components of inhibitory control. Additionally, the observed gender differences in control of behavior and attention could have important implications regarding negative consequences associated with alcohol-induced disinhibition in men and women. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  19. Total Dose Survivability of Hubble Electronic Components

    NASA Technical Reports Server (NTRS)

    Xapsos, M. A.; Stauffer, C.; Jordan, T.; Poivey, C.; Haskins, D. N.; Lum, G.; Pergosky, A. M.; Smith, D. C.; LaBel, K. A.

    2017-01-01

    A total dose analysis for exposure of electronic parts at the box level is presented for the Hubble Space Telescope. This was done using solid angle sectoring/3-dimensional ray trace and Monte Carlo radiation transport simulations. Results are discussed in terms of parts that are potential total dose concerns.

  20. New Approach to Total Dose Specification for Spacecraft Electronics

    NASA Technical Reports Server (NTRS)

    Xapsos, Michael

    2017-01-01

    Variability of the space radiation environment is investigated with regard to total dose specification for spacecraft electronics. It is shown to have a significant impact. A new approach is developed for total dose requirements that replaces the radiation design margin concept with failure probability during a mission.

  1. LTC1877 High Efficiency Regulator Total Ionizing Dose Test Report

    NASA Technical Reports Server (NTRS)

    Oldham, Timothy; Pellish, Jonathan; Boutte, Alvin

    2012-01-01

    This report presents total ionizing dose evaluation data for the Linear Technology Corporation LTC1877 high efficiency monolithic synchronous step-down regulator. Data sheet parameters were tracked as a function of ionizing dose up to a total of 20 krad(SiO2). Control devices were also used.

  2. Equal Opportunity Climate and Total Quality Management: A Preliminary Study.

    DTIC Science & Technology

    1994-09-01

    The purpose of the present study is to show the relationship between military Equal Opportunity (EO) and Total Quality Management (TQM). Three...military units were identified that had a recognized TQM program and had completed the Military Equal Opportunity Climate Survey (MEOCS). These three units...commitment, satisfaction, positive EO behaviors (minorities asked to make suggestions, socializing ), fair treatment, and supervision. Discussion

  3. SU-F-P-04: Implementation of Dose Monitoring Software: Successes and Pitfalls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Och, J

    2016-06-15

    Purpose: to successfully install a dose monitoring software (DMS) application to assist in CT protocol and dose management. Methods: Upon selecting the DMS, we began our implementation of the application. A working group composed of Medical Physics, Radiology Administration, Information Technology, and CT technologists was formed. On-site training in the application was supplied by the vendor. The decision was made to apply the process for all the CT protocols on all platforms at all facilities. Protocols were painstakingly mapped to the correct masters, and the system went ‘live’. Results: We are routinely using DMS as a tool in our Clinicalmore » Performance CT QA program. It is useful in determining the effectiveness of revisions to existing protocols, and establishing performance baselines for new units. However, the implementation was not without difficulty. We identified several pitfalls and obstacles which frustrated progress. Including: Training deficiencies, Nomenclature problems, Communication, DICOM variability. Conclusion: Dose monitoring software can be a potent tool for QA. However, implementation of the program can be problematic and requires planning, organization and commitment.« less

  4. Radon and Thoron Measured in Petrol and Gas-oil Exhaust Fumes by Using CR-39 and LR-115 II Nuclear Track Detectors: Radiation Doses to the Respiratory Tract of Mechanic Workers.

    PubMed

    Misdaq, M A; Chaouqi, A; Ouguidi, J; Touti, R; Mortassim, A

    2015-06-01

    Mechanic workers are exposed to exhaust fumes when controlling vehicle engines in motion inside repair shops. To assess radiation doses due to radon short-lived progeny from the inhalation of exhaust fumes by mechanic workers, concentrations of these radionuclides were measured in petrol (gasoline) and gas-oil exhaust fumes by evaluating mean critical angles of etching of the CR-39 and LR-115 type II SSNTDs for alpha particles emitted by the radon and thoron decay series. Committed effective doses due to ²¹⁸Po and ²¹⁴Po short-lived radon decay products from the inhalation of petrol and gas-oil exhaust fumes by workers were evaluated. A maximum value of 1.35 mSv y⁻¹ due to radon short-lived decay products from the inhalation of gas-oil exhaust fumes by mechanic workers was found, which is lower than the (3-10 mSv y⁻¹) dose limit interval for workers.

  5. DETERMINATION AND DOSE CONTRIBUTION OF URANIUM ISOTOPES AND 210Po ACTIVITY CONCENTRATIONS OF NATURAL SPRING WATERS IN THE PROVINCE OF GRANADA, SPAIN.

    PubMed

    Milena-Pérez, A; Piñero-García, F; Expósito-Suárez, V M; Mantero, J; Benavente, J; Ferro-García, M A

    2018-03-01

    The activity concentrations of alpha-emitters comprising isotopes of uranium (238, 234, 235U) and polonium (210Po) were measured using alpha-particle spectrometry in natural spring waters in the province of Granada, Spain. These water are consumed by the population of the zone who live in villages. This is almost half of the population of the whole region. Mean values of activity concentrations found are 42.61 ± 2.66; 49.55 ± 3.03; 1.64 ± 0.28 and 1.74 ± 0.15 mBq L-1 for 238U, 234U, 235U and 210Po, respectively. Finally, the radiological impact of the analysed waters has been determined, in terms of the estimation of the committed annual effective dose due to the ingestion of the water. The assessment has been carried out for five age groups with the aim to cover all the population. The calculated annual effective doses are observed to be below the prescribed dose limit of 100 μSv y-1 recommended by WHO.

  6. Total dose bias dependency and ELDRS effects in bipolar linear devices

    NASA Technical Reports Server (NTRS)

    Yui, C. C.; McClure, S. S.; Rex, B. G.; Lehman, J. M.; Minto, T. D.; Wiedeman, M.

    2002-01-01

    Total dose tests of several bipolar linear devices show sensitivity to both dose rate and bias during exposure. All devices exhibited Enhanced Low Dose Rate Sensitivity (ELDRS). An accelerated ELDRS test method for three different devices demonstrate results similar to tests at low dose rate. Behavior and critical parameters from these tests are compared and discussed.

  7. Maternal Filicide among Women Admitted to Forensic Psychiatric Institutions in Malaysia: Case Series.

    PubMed

    Razali, S; Salleh, R M; Yahya, B; Ahmad, S H

    2015-06-01

    To examine the characteristics of maternal filicide and describe the adverse life events experienced by women who have committed filicide and been hospitalised in forensic psychiatric institutions in Malaysia. Registration records from 2000 through 2012 of female patients from 2 main forensic psychiatric institutions in Malaysia were reviewed. The medical records of patients who had committed maternal filicide were selected and descriptively evaluated. A total of 18 cases of maternal filicide were identified. Family dysfunction that presented with marital discord, domestic violence, or husband with substance abuse was the main stress experienced by the women. Three social circumstances, including an adolescent who became a victim of date rape; immigrants who experienced sexual abuse; and filicide-suicide precipitated by financial difficulties were highlighted. Women who committed filicide had experienced various difficulties in their life. The presence of such life events might alert mental health professionals to investigate the possibility of filicide among their patients.

  8. Worldwide Market For Scientific Lasers

    NASA Astrophysics Data System (ADS)

    Westra, Sicco

    1989-06-01

    I'm going to talk about the worldwide market for scientific lasers. I felt we should start with a quote from our soon-to-be President and learn from him how he feels about the commitment that the government should make to R&D. "R&D is the economic Fountain of Youth, and we really should take good care of it because that is where our business is for the future." If you read through that quote, it is very clear that at least before the election, he made a very strong commitment to this. It will be interesting to see over the next four years whether he keeps to that commitment or not, but I happen to totally agree with what he is saying here. The R&D market, as I see it, is certainly, as far as lasers are concerned, the growth place for new technology and applications.

  9. The relationship between South Korean clinical nurses' attitudes toward organizations and voluntary turnover intention: A path analysis.

    PubMed

    Kim, Jong Kyung; Chang, Sun Ju

    2015-08-01

    The purpose of this study was to examine the relationship between attitudes toward their organizations and voluntary turnover intention among South Korean clinical nurses. Data from a total of 312 clinical nurses in six hospitals in South Korea were collected for the study. Both hierarchical multiple regression analysis and path analysis were used to analyse the data. The overall fit of the hypothetical model was good. Voluntary turnover intention was found to have significant direct pathways to job embeddedness and organizational commitment. Organizational commitment and satisfaction with organizational rewards had indirect pathways to voluntary turnover intention through job embeddedness. All variances explained 62.3% of the voluntary turnover intention scores. The findings suggest that greater job embeddedness, organizational commitment and satisfaction with organizational rewards lead to lower voluntary turnover intention among clinical nurses in South Korea. © 2014 Wiley Publishing Asia Pty Ltd.

  10. Joint minimization of uplink and downlink whole-body exposure dose in indoor wireless networks.

    PubMed

    Plets, D; Joseph, W; Vanhecke, K; Vermeeren, G; Wiart, J; Aerts, S; Varsier, N; Martens, L

    2015-01-01

    The total whole-body exposure dose in indoor wireless networks is minimized. For the first time, indoor wireless networks are designed and simulated for a minimal exposure dose, where both uplink and downlink are considered. The impact of the minimization is numerically assessed for four scenarios: two WiFi configurations with different throughputs, a Universal Mobile Telecommunications System (UMTS) configuration for phone call traffic, and a Long-Term Evolution (LTE) configuration with a high data rate. Also, the influence of the uplink usage on the total absorbed dose is characterized. Downlink dose reductions of at least 75% are observed when adding more base stations with a lower transmit power. Total dose reductions decrease with increasing uplink usage for WiFi due to the lack of uplink power control but are maintained for LTE and UMTS. Uplink doses become dominant over downlink doses for usages of only a few seconds for WiFi. For UMTS and LTE, an almost continuous uplink usage is required to have a significant effect on the total dose, thanks to the power control mechanism.

  11. Joint Minimization of Uplink and Downlink Whole-Body Exposure Dose in Indoor Wireless Networks

    PubMed Central

    Plets, D.; Joseph, W.; Vanhecke, K.; Vermeeren, G.; Wiart, J.; Aerts, S.; Varsier, N.; Martens, L.

    2015-01-01

    The total whole-body exposure dose in indoor wireless networks is minimized. For the first time, indoor wireless networks are designed and simulated for a minimal exposure dose, where both uplink and downlink are considered. The impact of the minimization is numerically assessed for four scenarios: two WiFi configurations with different throughputs, a Universal Mobile Telecommunications System (UMTS) configuration for phone call traffic, and a Long-Term Evolution (LTE) configuration with a high data rate. Also, the influence of the uplink usage on the total absorbed dose is characterized. Downlink dose reductions of at least 75% are observed when adding more base stations with a lower transmit power. Total dose reductions decrease with increasing uplink usage for WiFi due to the lack of uplink power control but are maintained for LTE and UMTS. Uplink doses become dominant over downlink doses for usages of only a few seconds for WiFi. For UMTS and LTE, an almost continuous uplink usage is required to have a significant effect on the total dose, thanks to the power control mechanism. PMID:25793213

  12. Engagement in reading and hobbies and risk of incident dementia: the MoVIES project.

    PubMed

    Hughes, Tiffany F; Chang, Chung-Chou H; Vander Bilt, Joni; Ganguli, Mary

    2010-08-01

    To examine whether there is an association between engagement in reading and hobbies and dementia risk in late life. A total of 942 members of a population-based, prospective cohort study were followed biennially to identify incident dementia cases. Cox proportional hazards models were used to estimate the risk of dementia in relation to baseline total number of activities and time commitment to reading and hobbies. A lower risk for dementia was found for a greater number of activities and for a high (about 1 hour each day) compared with low (less than 30 minutes each day) weekly time commitment to hobbies, independent of covariates. Only the protective effect of hobbies remained after methods were used to minimize bias due to potential preclinical dementia. Engaging in hobbies for 1 or more hours every day might be protective against dementia in late life.

  13. Commitment to Change and Challenges to Implementing Changes After Workplace-Based Assessment Rater Training.

    PubMed

    Kogan, Jennifer R; Conforti, Lisa N; Yamazaki, Kenji; Iobst, William; Holmboe, Eric S

    2017-03-01

    Faculty development for clinical faculty who assess trainees is necessary to improve assessment quality and impor tant for competency-based education. Little is known about what faculty plan to do differently after training. This study explored the changes faculty intended to make after workplace-based assessment rater training, their ability to implement change, predictors of change, and barriers encountered. In 2012, 45 outpatient internal medicine faculty preceptors (who supervised residents) from 26 institutions participated in rater training. They completed a commitment to change form listing up to five commitments and ranked (on a 1-5 scale) their motivation for and anticipated difficulty implementing each change. Three months later, participants were interviewed about their ability to implement change and barriers encountered. The authors used logistic regression to examine predictors of change. Of 191 total commitments, the most common commitments focused on what faculty would change about their own teaching (57%) and increasing direct observation (31%). Of the 183 commitments for which follow-up data were available, 39% were fully implemented, 40% were partially implemented, and 20% were not implemented. Lack of time/competing priorities was the most commonly cited barrier. Higher initial motivation (odds ratio [OR] 2.02; 95% confidence interval [CI] 1.14, 3.57) predicted change. As anticipated difficulty increased, implementation became less likely (OR 0.67; 95% CI 0.49, 0.93). While higher baseline motivation predicted change, multiple system-level barriers undermined ability to implement change. Rater-training faculty development programs should address how faculty motivation and organizational barriers interact and influence ability to change.

  14. Hydrocortisone Therapy in Catecholamine-Resistant Pediatric Septic Shock: A Pragmatic Analysis of Clinician Practice and Association With Outcomes.

    PubMed

    Nichols, Blake; Kubis, Sherri; Hewlett, Jennifer; Yehya, Nadir; Srinivasan, Vijay

    2017-09-01

    The 2012 Surviving Sepsis Campaign pediatric guidelines recommend stress dose hydrocortisone in children experiencing catecholamine-dependent septic shock with suspected or proven absolute adrenal insufficiency. We evaluated whether stress dose hydrocortisone therapy in children with catecholamine dependent septic shock correlated with random serum total cortisol levels and was associated with improved outcomes. Retrospective cohort study. Non-cardiac PICU. Critically ill children (1 mo to 18 yr) admitted between January 1, 2013, and December 31, 2013, with catecholamine dependent septic shock who had random serum total cortisol levels measured prior to potential stress dose hydrocortisone therapy. None. The cohort was dichotomized to random serum total cortisol less than 18 mcg/dL and greater than or equal to 18 mcg/dL. Associations of stress dose hydrocortisone with outcomes: PICU mortality, PICU and hospital length of stay, ventilator-free days, and vasopressor-free days were examined. Seventy children with catecholamine-dependent septic shock and measured random serum total cortisol levels were eligible (16% PICU mortality). Although 43% (30/70) had random serum total cortisol less than 18 μg/dL, 60% (42/70) received stress dose hydrocortisone. Children with random serum total cortisol less than 18 μg/dL had lower severity of illness and lower Vasopressor Inotrope Scores than those with random serum total cortisol greater than or equal to 18 μg/dL (all p < 0.05). Children with stress dose hydrocortisone had higher severity of illness and PICU mortality than those without stress dose hydrocortisone (all p < 0.05). Mean random serum total cortisol levels were similar in children with and without stress dose hydrocortisone (21.1 vs 18.7 μg/dL; p = 0.69). In children with random serum total cortisol less than 18 μg/dL, stress dose hydrocortisone was associated with greater PICU and hospital length of stay and fewer ventilator-free days (all p < 0.05). In children with random serum total cortisol greater than 18 μg/dL, stress dose hydrocortisone was associated with greater PICU mortality and fewer ventilator-free days and vasopressor-free days (all p < 0.05). Stress dose hydrocortisone therapy in children with catecholamine-dependent septic shock correlated more with severity of illness than random serum total cortisol levels and was associated with worse outcomes, irrespective of random serum total cortisol levels.

  15. Supervisor vs. employee safety perceptions and association with future injury in US limited-service restaurant workers.

    PubMed

    Huang, Yueng-Hsiang; Verma, Santosh K; Chang, Wen-Ruey; Courtney, Theodore K; Lombardi, David A; Brennan, Melanye J; Perry, Melissa J

    2012-07-01

    Many studies have found management commitment to safety to be an important construct of safety climate. This study examined the association between supervisor and employee (shared and individual) perceptions of management commitment to safety and the rate of future injuries in limited-service restaurant workers. A total of 453 participants (34 supervisors/managers and 419 employees) from 34 limited-service restaurants participated in a prospective cohort study. Employees' and managers' perceptions of management commitment to safety and demographic variables were collected at the baseline. The survey questions were made available in three languages: English, Spanish, and Portuguese. For the following 12 weeks, participants reported their injury experience and weekly work hours. A multivariate negative binomial generalized estimating equation model with compound symmetry covariance structure was used to assess the association between the rate of self-reported injuries and measures of safety perceptions. There were no significant relationships between supervisor and either individual or shared employee perceptions of management commitment to safety. Only individual employee perceptions were significantly associated with future employee injury experience but not supervisor safety perceptions or shared employee perceptions. Individual employee perception of management commitment to safety is a significant predictor for future injuries in restaurant environments. A study focusing on employee perceptions would be more predictive of injury outcomes than supervisor/manager perceptions. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. SU-G-BRB-14: Uncertainty of Radiochromic Film Based Relative Dose Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Devic, S; Tomic, N; DeBlois, F

    2016-06-15

    Purpose: Due to inherently non-linear dose response, measurement of relative dose distribution with radiochromic film requires measurement of absolute dose using a calibration curve following previously established reference dosimetry protocol. On the other hand, a functional form that converts the inherently non-linear dose response curve of the radiochromic film dosimetry system into linear one has been proposed recently [Devic et al, Med. Phys. 39 4850–4857 (2012)]. However, there is a question what would be the uncertainty of such measured relative dose. Methods: If the relative dose distribution is determined going through the reference dosimetry system (conversion of the response bymore » using calibration curve into absolute dose) the total uncertainty of such determined relative dose will be calculated by summing in quadrature total uncertainties of doses measured at a given and at the reference point. On the other hand, if the relative dose is determined using linearization method, the new response variable is calculated as ζ=a(netOD)n/ln(netOD). In this case, the total uncertainty in relative dose will be calculated by summing in quadrature uncertainties for a new response function (σζ) for a given and the reference point. Results: Except at very low doses, where the measurement uncertainty dominates, the total relative dose uncertainty is less than 1% for the linear response method as compared to almost 2% uncertainty level for the reference dosimetry method. The result is not surprising having in mind that the total uncertainty of the reference dose method is dominated by the fitting uncertainty, which is mitigated in the case of linearization method. Conclusion: Linearization of the radiochromic film dose response provides a convenient and a more precise method for relative dose measurements as it does not require reference dosimetry and creation of calibration curve. However, the linearity of the newly introduced function must be verified. Dave Lewis is inventor and runs a consulting company for radiochromic films.« less

  17. Four-Dimensional Patient Dose Reconstruction for Scanned Ion Beam Therapy of Moving Liver Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richter, Daniel; TU Darmstadt, Darmstadt; Saito, Nami

    2014-05-01

    Purpose: Estimation of the actual delivered 4-dimensional (4D) dose in treatments of patients with mobile hepatocellular cancer with scanned carbon ion beam therapy. Methods and Materials: Six patients were treated with 4 fractions to a total relative biological effectiveness (RBE)–weighted dose of 40 Gy (RBE) using a single field. Respiratory motion was addressed by dedicated margins and abdominal compression (5 patients) or gating (1 patient). 4D treatment dose reconstructions based on the treatment records and the measured motion monitoring data were performed for the single-fraction dose and a total of 17 fractions. To assess the impact of uncertainties in the temporalmore » correlation between motion trajectory and beam delivery sequence, 3 dose distributions for varying temporal correlation were calculated per fraction. For 3 patients, the total treatment dose was formed from the fractional distributions using all possible combinations. Clinical target volume (CTV) coverage was analyzed using the volumes receiving at least 95% (V{sub 95}) and 107% (V{sub 107}) of the planned doses. Results: 4D dose reconstruction based on daily measured data is possible in a clinical setting. V{sub 95} and V{sub 107} values for the single fractions ranged between 72% and 100%, and 0% and 32%, respectively. The estimated total treatment dose to the CTV exhibited improved and more robust dose coverage (mean V{sub 95} > 87%, SD < 3%) and overdose (mean V{sub 107} < 4%, SD < 3%) with respect to the single-fraction dose for all analyzed patients. Conclusions: A considerable impact of interplay effects on the single-fraction CTV dose was found for most of the analyzed patients. However, due to the fractionated treatment, dose heterogeneities were substantially reduced for the total treatment dose. 4D treatment dose reconstruction for scanned ion beam therapy is technically feasible and may evolve into a valuable tool for dose assessment.« less

  18. Game-Related Statistics that Discriminated Winning, Drawing and Losing Teams from the Spanish Soccer League

    PubMed Central

    Lago-Peñas, Carlos; Lago-Ballesteros, Joaquín; Dellal, Alexandre; Gómez, Maite

    2010-01-01

    The aim of the present study was to analyze men’s football competitions, trying to identify which game-related statistics allow to discriminate winning, drawing and losing teams. The sample used corresponded to 380 games from the 2008-2009 season of the Spanish Men’s Professional League. The game-related statistics gathered were: total shots, shots on goal, effectiveness, assists, crosses, offsides commited and received, corners, ball possession, crosses against, fouls committed and received, corners against, yellow and red cards, and venue. An univariate (t-test) and multivariate (discriminant) analysis of data was done. The results showed that winning teams had averages that were significantly higher for the following game statistics: total shots (p < 0.001), shots on goal (p < 0.01), effectiveness (p < 0.01), assists (p < 0.01), offsides committed (p < 0.01) and crosses against (p < 0.01). Losing teams had significantly higher averages in the variable crosses (p < 0.01), offsides received (p < 0. 01) and red cards (p < 0.01). Discriminant analysis allowed to conclude the following: the variables that discriminate between winning, drawing and losing teams were the total shots, shots on goal, crosses, crosses against, ball possession and venue. Coaches and players should be aware for these different profiles in order to increase knowledge about game cognitive and motor solicitation and, therefore, to evaluate specificity at the time of practice and game planning. Key points This paper increases the knowledge about soccer match analysis. Give normative values to establish practice and match objectives. Give applications ideas to connect research with coaches’ practice. PMID:24149698

  19. Total quality management in American industry.

    PubMed

    Widtfeldt, A K; Widtfeldt, J R

    1992-07-01

    The definition of total quality management is conformance to customer requirements and specifications, fitness for use, buyer satisfaction, and value at an affordable price. The three individuals who have developed the total quality management concepts in the United States are W.E. Deming, J.M. Juran, and Philip Crosby. The universal principles of total quality management are (a) a customer focus, (b) management commitment, (c) training, (d) process capability and control, and (e) measurement through quality improvement tools. Results from the National Demonstration Project on Quality Improvement in Health Care showed the principles of total quality management could be applied to healthcare.

  20. The relationship between quality management practices and organisational performance: A structural equation modelling approach

    NASA Astrophysics Data System (ADS)

    Jamaluddin, Z.; Razali, A. M.; Mustafa, Z.

    2015-02-01

    The purpose of this paper is to examine the relationship between the quality management practices (QMPs) and organisational performance for the manufacturing industry in Malaysia. In this study, a QMPs and organisational performance framework is developed according to a comprehensive literature review which cover aspects of hard and soft quality factors in manufacturing process environment. A total of 11 hypotheses have been put forward to test the relationship amongst the six constructs, which are management commitment, training, process management, quality tools, continuous improvement and organisational performance. The model is analysed using Structural Equation Modeling (SEM) with AMOS software version 18.0 using Maximum Likelihood (ML) estimation. A total of 480 questionnaires were distributed, and 210 questionnaires were valid for analysis. The results of the modeling analysis using ML estimation indicate that the fits statistics of QMPs and organisational performance model for manufacturing industry is admissible. From the results, it found that the management commitment have significant impact on the training and process management. Similarly, the training had significant effect to the quality tools, process management and continuous improvement. Furthermore, the quality tools have significant influence on the process management and continuous improvement. Likewise, the process management also has a significant impact to the continuous improvement. In addition the continuous improvement has significant influence the organisational performance. However, the results of the study also found that there is no significant relationship between management commitment and quality tools, and between the management commitment and continuous improvement. The results of the study can be used by managers to prioritize the implementation of QMPs. For instances, those practices that are found to have positive impact on organisational performance can be recommended to managers so that they can allocate resources to improve these practices to get better performance.

  1. 75 FR 47258 - Determination of Total Amounts of Fiscal Year 2011 Tariff-Rate Quotas for Raw Cane Sugar and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-05

    ... Determination of Total Amounts of Fiscal Year 2011 Tariff-Rate Quotas for Raw Cane Sugar and Certain Sugars...) 2011 in-quota aggregate quantity of the raw, as well as, refined and specialty sugar Tariff-Rate Quotas (TRQ) as required under the U.S. World Trade Organization (WTO) commitments. The FY 2011 raw cane sugar...

  2. Progress on the Journey to Total Quality Management: Using the Myers-Briggs Type Indicator and the Adjective Check List in Management Development.

    ERIC Educational Resources Information Center

    Mani, Bonnie G.

    1995-01-01

    In an Internal Revenue Service office using total quality management (TQM), the management development program uses Myers Briggs Type Indicator and Adjective Check List for manager self-assessment. Because management commitment is essential to TQM, the process is a way of enhancing leadership skills and demonstrating appreciation of diversity. (SK)

  3. Effect of personality traits, age and sex on aggressive driving: Psychometric adaptation of the Driver Aggression Indicators Scale in China.

    PubMed

    Zhang, Huihui; Qu, Weina; Ge, Yan; Sun, Xianghong; Zhang, Kan

    2017-06-01

    This study aimed to assess the reliability and validity of the Chinese version of the Driver Aggression Indicators Scale (DAIS), which measures aggressive driving behaviors. Besides, demographic variables (sex and age) and the big five personality traits were examined as potential impact factors of aggressive driving. A total of 422 participants completed the DAIS, Big Five Personality Inventory (BFPI), and the socio-demographic scale. First, psychometric results confirmed that the DAIS had a stable two-factor structure and acceptable internal consistency. Then, agreeableness and conscientiousness were negatively correlated with hostile aggression and revenge committed by the drivers themselves, while neuroticism was positively correlated with aggressive driving committed by the drivers themselves. Meanwhile, more agreeable drivers may perceive less hostile aggression and revenge. More neurotic drivers may perceive more aggressive warning. Finally, the effects of age and sex on aggressive driving were not same as most studies. We found that older age group perceived and committed more hostile acts of aggression and revenge than younger age groups. Female drivers of 49-60 years perceived more aggressive warnings committed by other drivers. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Predictors of motivation for abstinence at the end of outpatient substance abuse treatment

    PubMed Central

    Laudet, Alexandre B.; Stanick, Virginia

    2010-01-01

    Commitment to abstinence, a motivational construct, is a strong predictor of reductions in drug and alcohol use. Level of commitment to abstinence at treatment end predicts sustained abstinence, a requirement for recovery. This study sought to identify predictors of commitment to abstinence at treatment end to guide clinical practice and to inform the conceptualization of motivational constructs. Polysubstance users (N = 250) recruited at the start of outpatient treatment were re-interviewed at the end of services. Based on the extant literature, potential predictors were during treatment measures of substance use and related cognitions, psychological functioning, recovery supports, stress, quality of life satisfaction, and treatment experiences. In multivariate analyses, perceived harm of future drug use, abstinence self-efficacy, quality of life satisfaction, and number of network members in 12-step recovery contributed 26.6% of the variance explained in the dependent variable, a total of 49.6% when combined with the control variables (demographics and baseline level of the outcome). Gender subgroup analyses yielded largely similar results. Clinical implications of findings for maximizing commitment to abstinence when clients leave treatment are discussed as are future research directions. PMID:20185267

  5. Pilot study for evidence-based nursing management: improving the levels of job satisfaction, organizational commitment, and intent to leave among nurses in Turkey.

    PubMed

    Arslan Yurumezoglu, Havva; Kocaman, Gulseren

    2012-06-01

    Because of the nursing shortage problem, an important goal for nurse managers is preventing nurses from leaving the organization. This study analyzed the effect of evidence-based nursing management practices on nurses' levels of job satisfaction, organizational commitment, and intent to leave using the Promoting Action Research Implementation in Health Service framework as a guide. This study employed a single-group, quasi-experimental, pretest-post-test design with repeated measures. Data were collected using the Minnesota Job Satisfaction Questionnaire and the Organizational Commitment Scale. The study was conducted at a 127-bed private, accredited hospital. The sample was composed of 58 nurses who participated in all three measurements. Data analysis was conducted using repeated-measures anova and the Cochrane Q-test. An improvement was observed in the nurses' intrinsic, extrinsic, and total satisfaction levels, and in the degree of normative commitment. Nurse managers stated that they benefited from this study. In order to find effective and long-lasting solutions to the nursing shortage problem, evidence-based recommendations should be used in nursing management. © 2012 Blackwell Publishing Asia Pty Ltd.

  6. Sense of community, organizational commitment and quality of services.

    PubMed

    Lampinen, Mai-Stiina; Suutala, ElinaAnnikki; Konu, Anne Irmeli

    2017-10-02

    Purpose The purpose of this paper is to examine how factors associated with a sense of community in the workplace are connected with organizational commitment and the quality of services among frontline managers and middle managers in social and health care services in Finland. Design/methodology/approach A questionnaire designed specifically for this research was sent to 241 lower-level and middle-level managers in social and health care services in central Finland. A total of 136 managers completed the questionnaire (response rate 56 per cent). The results were analyzed using descriptive statistics, exploratory factor analysis, Spearman's rank-order correlation coefficient and multiple linear regression analyses. Findings The study showed that feeling a sense of belonging, mutual trust and appreciation, and open interaction among colleagues were connected to organizational commitment for frontline managers and middle managers in social and health care services in Finland. Correspondingly, an open flow of information in the organization, job meaningfulness and appreciation received from managers' superiors were connected to the quality of services. Originality/value This study provides information on the factors that influence social and health care managers' organizational commitment and on items connected to their experience of the quality of services.

  7. An age dependent model for radium metabolism in man.

    PubMed

    Johnson, J R

    1983-01-01

    The model developed by a Task Group of Committee 2 of ICRP to describe Alkaline Earth Metabolism in Adult Man (ICRP Publication 20) has been modified so that recycling is handled explicitly, and retention in mineral bone is represented by second compartments rather than by the product of a power function and an exponential. This model has been extended to include all ages from birth to adult man, and has been coupled with modified "ICRP" lung and G.I. tract models so that activity in organs can be calculated as functions of time during or after exposures. These activities, and age dependent "specific effective energy" factors, are then used to calculate age dependent dose rates, and dose commitments. This presentation describes this work, with emphasis on the model parameters and results obtained for radium.

  8. Hematopoietic stimulation by porphyrin photosensitizers (Invited Paper)

    NASA Astrophysics Data System (ADS)

    Levy, Julia G.; Hunt, David W. C.; Mitchell, David W.; Jamieson, Catriona H. M.

    1992-06-01

    The effects of the photosensitizers, PhotofrinTM and benozoporphyrin derivative monoacid ring A (BPD) on a variety of hematopoietic cell functions have been studied, both in the presence and absence of light activation. A marked increase in hematopoiesis was observed in the bone marrow and spleens of DBA/2 mice administered high dose Photofrin but not BPD. This was manifested in an increased relative spleen weight, nucleated spleen cell number and circulating white blood cell concentration 7 days following Photofrin injection. We have shown that BPD and light doses just below phototoxic ranges stimulate the growth of human colony forming committed myeloid progenitors as well as pluripotent stem cells grown in long term marrow culture. Studies on the effect of BPD on the function of T lymphocytes in the absence of light has also demonstrated a stimulatory effect. The dose range in which this is observed is considerably broader than that observed with light activation. The mechanisms involved in this stimulatory effect have been studied and are discussed.

  9. Environmental consequences of postulated plutonium releases from Westinghouse PFDL, Cheswick, Pennsylvania, as a result of severe natural phenomena

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McPherson, R.B.; Watson, E.C.

    1979-06-01

    Potential environmental consequences in terms of radiation dose to people are presented for postulated accidents due to earthquakes, tornadoes, high straight-line winds, and floods. Maximum plutonium deposition values are given for significant locations around the site. All important potential exposure pathways are examined. The most likely calculated 50-year collective committed dose equivalents are all much lower than the collective dose equivalent expected from 50 years of exposure to natural background radiation and medical x-rays except Earthquake No. 4 and the 260-mph tornado. The most likely maximum residual plutonium contamination estimated to be deposited offsite following Earthquake No. 4, and themore » 200-mph and 260-mph tornadoes are above the Environmental Protection Agency's (EPA) proposed guideline for plutonium in the general environment of 0.2 ..mu..Ci/m/sup 2/. The deposition values following the other severe natural phenomena are below the EPA proposed guideline.« less

  10. A comparative analysis of warfarin and low-dose heparin as thromboembolism prophylaxis in total hip replacement patinets.

    PubMed Central

    Ritter, M A; HamiltonCW

    1975-01-01

    Warfarin, low-dose heparin, or a combination of low-dose heparin and hydrocortisone was administered to 300 patients undergoing total hip replacement. The lowest incidence of thromboembolic (5 per cent) was attained with Warfarin. Further investigation into the method of administration of low-dose heparin is necessary before it can be used effectively as thromboembolism prophylaxis in total hip replacement patients. The addition of hydrocortisone was not found useful. PMID:1138642

  11. Estimation of immunization providers' activities cost, medication cost, and immunization dose errors cost in Iraq.

    PubMed

    Al-lela, Omer Qutaiba B; Bahari, Mohd Baidi; Al-abbassi, Mustafa G; Salih, Muhannad R M; Basher, Amena Y

    2012-06-06

    The immunization status of children is improved by interventions that increase community demand for compulsory and non-compulsory vaccines, one of the most important interventions related to immunization providers. The aim of this study is to evaluate the activities of immunization providers in terms of activities time and cost, to calculate the immunization doses cost, and to determine the immunization dose errors cost. Time-motion and cost analysis study design was used. Five public health clinics in Mosul-Iraq participated in the study. Fifty (50) vaccine doses were required to estimate activities time and cost. Micro-costing method was used; time and cost data were collected for each immunization-related activity performed by the clinic staff. A stopwatch was used to measure the duration of activity interactions between the parents and clinic staff. The immunization service cost was calculated by multiplying the average salary/min by activity time per minute. 528 immunization cards of Iraqi children were scanned to determine the number and the cost of immunization doses errors (extraimmunization doses and invalid doses). The average time for child registration was 6.7 min per each immunization dose, and the physician spent more than 10 min per dose. Nurses needed more than 5 min to complete child vaccination. The total cost of immunization activities was 1.67 US$ per each immunization dose. Measles vaccine (fifth dose) has a lower price (0.42 US$) than all other immunization doses. The cost of a total of 288 invalid doses was 744.55 US$ and the cost of a total of 195 extra immunization doses was 503.85 US$. The time spent on physicians' activities was longer than that spent on registrars' and nurses' activities. Physician total cost was higher than registrar cost and nurse cost. The total immunization cost will increase by about 13.3% owing to dose errors. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. The radiation dosimeter on-board the FY-4 Satellite

    NASA Astrophysics Data System (ADS)

    Zhang, B.; Sun, Y.; Zhang, S.; Zhang, X.; Sun, Y.; Jing, T.

    2017-12-01

    The total radiation dose effect can lead to a decrease in the performance of satellite devices or materials. Accurately obtaining the total radiation dose during satellite operation could help to analyze the abnormality of payloads in orbit and optimize the design of radiation shielding. The radiation dosimeter is one of the space environmental monitoring devices on the "FY-4" satellite, which is a new generation of geostationary meteorological satellite. The dosimeter consists of 8 detectors, which are installed in different locations of the satellite, to obtain the total radiation dose with different shielding thickness and different orientations. To measure a total radiation dose up to 2000krad(Si), 100nm ion implantation RADFET was used. To improve the sensitivity of the dosimeter, the bias voltage of RADFET is set to 15V, and a 10V, 15-bit A/D is adopted to digitalize the RADFET's threshold voltage, which is increased as the total radiation dose grows. In addition, the temperature effect of RADFET is corrected from the measured temperature on orbit. The preliminary monitoring results show that the radiation dose is less than 35rad (Si) per day at 0.87 mm shielding thickness of equivalent aluminum in the geostationary orbit, and the dose in Y direction of the satellite is less than those in the X and Z directions. The radiation dose at the thickness of 3.87 mm equivalent aluminum is less than 1rad(Si)/day. It is found that the daily total dose measured by the dosimeter has a strong correlation with the flux of high energy electrons.

  13. Rates of Change in Naturalistic Psychotherapy: Contrasting Dose-Effect and Good-Enough Level Models of Change

    ERIC Educational Resources Information Center

    Baldwin, Scott A.; Berkeljon, Arjan; Atkins, David C.; Olsen, Joseph A.; Nielsen, Stevan L.

    2009-01-01

    Most research on the dose-effect model of change has combined data across patients who vary in their total dose of treatment and has implicitly assumed that the rate of change during therapy is constant across doses. In contrast, the good-enough level model predicts that rate of change will be related to total dose of therapy. In this study, the…

  14. Compendium of Current Total Ionizing Dose and Displacement Damage Results from NASA Goddard Space Flight Center and NASA Electronic Parts and Packaging Program

    NASA Technical Reports Server (NTRS)

    Topper, Alyson D.; Campola, Michael J.; Chen, Dakai; Casey, Megan C.; Yau, Ka-Yen; Cochran, Donna J.; Label, Kenneth A.; Ladbury, Raymond L.; Mondy, Timothy K.; O'Bryan, Martha V.; hide

    2017-01-01

    Total ionizing dose and displacement damage testing was performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices. Displacement Damage, Optoelectronics, Proton Damage, Single Event Effects, and Total Ionizing Dose.

  15. The Quality Revolution in Education.

    ERIC Educational Resources Information Center

    Bonstingl, John Jay

    1992-01-01

    Whether viewed through Deming's 14 points, Juran's Trilogy, or Kaoru Ishikawa's Thought Revolution, Total Quality Management embodies 4 fundamental tenets: primary focus on customers and suppliers, universal commitment to continuous improvement, a systems approach, and top management responsibility. Educational organizations are recreating their…

  16. Nudging Guideline-Concordant Antibiotic Prescribing

    PubMed Central

    Meeker, Daniella; Knight, Tara K.; Friedberg, Mark W.; Linder, Jeffrey A.; Goldstein, Noah J.; Fox, Craig R.; Rothfeld, Alan; Diaz, Guillermo; Doctor, Jason N.

    2015-01-01

    IMPORTANCE “Nudges” that influence decision making through subtle cognitive mechanisms have been shown to be highly effective in a wide range of applications, but there have been few experiments to improve clinical practice. OBJECTIVE To investigate the use of a behavioral “nudge” based on the principle of public commitment in encouraging the judicious use of antibiotics for acute respiratory infections (ARIs). DESIGN, SETTING, AND PARTICIPANTS Randomized clinical trial in 5 outpatient primary care clinics. A total of 954 adults had ARI visits during the study timeframe: 449 patients were treated by clinicians randomized to the posted commitment letter (335 in the baseline period, 114 in the intervention period); 505 patients were treated by clinicians randomized to standard practice control (384 baseline, 121 intervention). INTERVENTIONS The intervention consisted of displaying poster-sized commitment letters in examination rooms for 12 weeks. These letters, featuring clinician photographs and signatures, stated their commitment to avoid inappropriate antibiotic prescribing for ARIs. MAIN OUTCOMES AND MEASURES Antibiotic prescribing rates for antibiotic-inappropriate ARI diagnoses in baseline and intervention periods, adjusted for patient age, sex, and insurance status. RESULTS Baseline rates were 43.5% and 42.8% for control and poster, respectively. During the intervention period, inappropriate prescribing rates increased to 52.7% for controls but decreased to 33.7% in the posted commitment letter condition. Controlling for baseline prescribing rates, we found that the posted commitment letter resulted in a 19.7 absolute percentage reduction in inappropriate antibiotic prescribing rate relative to control (P = .02). There was no evidence of diagnostic coding shift, and rates of appropriate antibiotic prescriptions did not diminish over time. CONCLUSIONS AND RELEVANCE Displaying poster-sized commitment letters in examination rooms decreased inappropriate antibiotic prescribing for ARIs. The effect of this simple, low-cost intervention is comparable in magnitude to costlier, more intensive quality-improvement efforts. TRIAL REGISTRATION clinicaltrials.gov identifier: NCT01767064 PMID:24474434

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Podonsky, Glenn S.

    The U.S. Department of Energy (DOE) Office of Analysis within the Office of Health, Safety and Security (HSS) publishes the annual DOE Occupational Radiation Exposure Report to provide an overview of the status of radiation protection practices at DOE (including the National Nuclear Security Administration [NNSA]). The DOE 2012 Occupational Radiation Exposure Report provides an evaluation of DOE-wide performance regarding compliance with Title 10, Code of Federal Regulations (C.F.R.), Part 835, Occupational Radiation Protection dose limits and as low as reasonably achievable (ALARA) process requirements. In addition, the report provides data to DOE organizations responsible for developing policies for protectionmore » of individuals from the adverse health effects of radiation. The report provides a summary and an analysis of occupational radiation exposure information from the monitoring of individuals involved in DOE activities. Over the past 5-year period, the occupational radiation exposure information is analyzed in terms of aggregate data, dose to individuals, and dose by site. As an indicator of the overall amount of radiation dose received during the conduct of operations at DOE, the report includes information on collective total effective dose (TED). The TED is comprised of the effective dose (ED) from external sources, which includes neutron and photon radiation, and the internal committed effective dose (CED), which results from the intake of radioactive material into the body. The collective ED from photon exposure decreased by 23% between 2011 and 2012, while the neutron dose increased by 5%. The internal dose components of the collective TED decreased by 7%. Over the past 5-year period, 99.99% of the individuals receiving measurable TED have received doses below the 2 roentgen equivalent in man (rems) (20 millisievert [mSv]) TED administrative control level (ACL), which is well below the DOE regulatory limit of 5 rems (50 mSv) TED annually. The occupational radiation exposure records show that in 2012, DOE facilities continued to comply with DOE dose limits and ACLs and worked to minimize exposure to individuals. The DOE collective TED decreased 17.1% from 2011 to 2012. The collective TED decreased at three of the five sites with the largest collective TED. u Idaho Site – Collective dose reductions were achieved as a result of continuing improvements at the Advanced Mixed Waste Treatment Project (AMWTP) through the planning of drum movements that reduced the number of times a container is handled; placement of waste containers that created highradiation areas in a centralized location; and increased worker awareness of high-dose rate areas. In addition, Idaho had the largest decrease in the total number of workers with measurable TED (1,143 fewer workers). u Hanford Site (Hanford) – An overall reduction of decontamination and decommissioning (D&D) activities at the Plutonium Finishing Plant (PFP) and Transuranic (TRU) retrieval activities resulted in collective dose reductions. u Savannah River Site (SRS) – Reductions were achieved through ALARA initiatives employed site wide. The Solid Waste Management Facility used extended specialty tools, cameras and lead shield walls to facilitate removal of drums. These tools and techniques reduce exposure time through improved efficiency, increase distance from the source of radiation by remote monitoring, shield the workers to lower the dose rate, and reduce the potential for contamination and release of material through repacking of waste. Overall, from 2011 to 2012, there was a 19% decrease in the number of workers with measurable dose. Furthermore, due to a slight decrease in both the DOE workforce (7%) and monitored workers (10%), the ratio of workers with measurable doses to monitored workers decreased to 13%. Another primary indicator of the level of radiation exposure covered in this report is the average measurable dose, which normalizes the collective dose over the population of workers who actually received a measurable dose. The average measurable TED increased by 3% from 2011 to 2012. Additional analyses show that the dose distribution in 2012 was similar to the distribution in 2011. In 2012, 13% of the monitored workers received a measurable TED and the average measurable TED, 0.069 rem, was less than 2% of the DOE limit. From 2011 to 2012, the collective TED and the number of individuals with measurable TED decreased 17.1% and 19%, respectively. These decreases were mainly due to an overall reduction of D&D activities at the PFP and TRU retrieval activities at Hanford; a 78% decrease in the number of targeted waste drums that were processed at the Idaho Site’s Accelerated Retrieval Project (ARP) from 5,566 drums in 2011 to a total of 1,211 drums processed in 2012; and ALARA initiatives employed site wide at SRS. In addition, the decreases were the result of decreased American Recovery and Reinvestment Act (ARRA) activities and continuing D&D, particularly at the DOE sites that comprise the majority of DOE collective dose. Over the past 5 years, the size of the monitored workforce has remained at a fairly stable level (within 12%), while the collective dose has varied up to 37%. No reported doses exceeded the DOE occupational limit of 5 rems TED in 2012 and no reported doses exceeded the DOE ACL of 2 rems TED.« less

  18. Job satisfaction, organisation commitment and retention in the public workforce: a survey among pharmacists in Malaysia.

    PubMed

    Chua, Gin Nie; Yee, Lai Jiuan; Sim, Bee Ai; Tan, Keat Hin; Sin, Ng Khai; Hassali, Mohammed Azmi; Shafie, Asrul Akmal; Ooi, Guat See

    2014-08-01

    The aims of the study were to assess job satisfaction and organisational commitment among pharmacists working in the public sector and its influence on their likelihood to stay within the public workforce. A cross-sectional survey was conducted among all fully registered pharmacists (FRPs) in the northern states of Malaysia in 2009 (n = 467). The questionnaire consisted of three sections to capture the demographic characteristics of the respondents, assess job satisfaction and organisational commitment of the respondents and their likelihood of staying in public service. A total of 247 FRPs (response rate 52.9%) in the northern region of Malaysia participated in this survey. Majority of the respondents were women (n = 205, 83.0%), of Chinese ethnicity (n = 155, 62.8%), graduates from public universities (n = 173, 70.0%), single (n = 172, 69.6%), with a median age of 27 years (interquartile range (IQR) 2.0) and had worked with the Ministry of Health for a median of 2.75 years (IQR 1.63). The mean job satisfaction and organisational commitment score were 58.09 (standard deviation (SD) 11.83) and 53.46 (SD 6.65) respectively out of a maximum possible score of 90. Majority of the respondents claimed that they were likely to stay in public service (n = 176, 71.3%). Their likelihood of staying in public service was affected by respondents’ gender, ethnicity, job satisfaction and organisational commitment. The findings from this study provide stakeholders with evidence on factors and issues affecting pharmacists’ job satisfaction and commitment in the public workforce as well as the likely turnover rate with an early cohort of pharmacists affected by the compulsory service.

  19. Measurement of radioactivity and heavy metal levels in edible vegetables and their impact on Kuala Selangor communities of Peninsular Malaysia.

    PubMed

    Asaduzzaman, Kh; Khandaker, M U; Amin, Y M; Zainuddin, Z; Farook, M S; Bradley, D A

    2015-11-01

    Vegetable is an essential daily diet item for the people of Malaysia. This work addressed the radiation and heavy metal exposure scenarios through the consumption of vegetables. Kuala Selangor is located in Sungai Selangor estuary in the west coast of Peninsular Malaysia, which is susceptible to pollution load due to the presence of large-scale industrial and human activities. Radioactivity and heavy metals level in human diet is of particular concern for the assessment of possible radiological and chemical hazards to human health. Therefore, a comprehensive study was carried out to determine the radioactivity levels ((226)Ra, (228)Ra and (40)K) and heavy metal concentrations (Cr, As, Cd, Mn, Mg, Al, Sr, Rb, Sb, Ba, Hg, Fe, Ni, Zn, Cu, Bi and Pb) in 10 varieties of vegetable collected from different farmlands in Kuala Selangor region. The committed doses for (226)Ra, (228)Ra and (40)K due to consumption of vegetables were found 16.6±1.3, 23.6±1.7 and 58±5 µSv y(-1), respectively, with a total of 98±8 µSv y(-1). This dose imposes no significant threat to human health. The estimated cancer risk shows that probability of increase in cancer risk from daily intake of vegetables is only a minor fraction of International Commission on Radiological Protection values. The concentrations of heavy metal were below the daily intake recommended by the international organisations. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Continuing evaluation of bipolar linear devices for total dose bias dependency and ELDRS effects

    NASA Technical Reports Server (NTRS)

    McClure, Steven S.; Gorelick, Jerry L.; Yui, Candice; Rax, Bernard G.; Wiedeman, Michael D.

    2003-01-01

    We present results of continuing efforts to evaluate total dose bias dependency and ELDRS effects in bipolar linear microcircuits. Several devices were evaluated, each exhibiting moderate to significant bias and/or dose rate dependency.

  1. Committed CO2 Emissions of China's Coal-fired Power Plants

    NASA Astrophysics Data System (ADS)

    Suqin, J.

    2016-12-01

    The extent of global warming is determined by the cumulative effects of CO2 in the atmosphere. Coal-fired power plants, the largest anthropogenic source of CO2 emissions, produce large amount of CO2 emissions during their lifetimes of operation (committed emissions), which thus influence the future carbon emission space under specific targets on mitigating climate change (e.g., the 2 degree warming limit relative to pre-industrial levels). Comprehensive understanding of committed CO2 emissions for coal-fired power generators is urgently needed in mitigating global climate change, especially in China, the largest global CO2emitter. We calculated China's committed CO2 emissions from coal-fired power generators installed during 1993-2013 and evaluated their impact on future emission spaces at the provincial level, by using local specific data on the newly installed capacities. The committed CO2 emissions are calculated as the product of the annual coal consumption from newly installed capacities, emission factors (CO2emissions per unit crude coal consumption) and expected lifetimes. The sensitivities about generators lifetimes and the drivers on provincial committed emissions are also analyzed. Our results show that these relatively recently installed coal-fired power generators will lead to 106 Gt of CO2 emissions over the course of their lifetimes, which is more than three times the global CO2 emissions from fossil fuels in 2010. More than 80% (85 Gt) of their total committed CO2 will be emitted after 2013, which are referred to as the remaining emissions. Due to the uncertainties of generators lifetime, these remaining emissions would increase by 45 Gt if the lifetimes of China's coal-fired power generators were prolonged by 15 years. Furthermore, the remaining emissions are very different among various provinces owing to local developments and policy disparities. Provinces with large amounts of secondary industry and abundant coal reserves have higher committed emissions. The national and provincial CO2 emission mitigation objectives might be greatly restricted by existing and planned power plants in China. The policy implications of our results have also been discussed.

  2. Usage and Dose Response of a Mobile Acceptance and Commitment Therapy App: Secondary Analysis of the Intervention Arm of a Randomized Controlled Trial

    PubMed Central

    Lappalainen, Raimo; Välkkynen, Pasi; Sairanen, Essi; Lappalainen, Päivi; Karhunen, Leila; Peuhkuri, Katri; Korpela, Riitta; Kolehmainen, Marjukka; Ermes, Miikka

    2016-01-01

    Background Mobile phone apps offer a promising medium to deliver psychological interventions. A mobile app based on Acceptance and Commitment Therapy (ACT) was developed and studied in a randomized controlled trial (RCT). Objective To study usage metrics of a mobile ACT intervention and dose-response relationship between usage and improvement in psychological flexibility. Methods An RCT was conducted to investigate the effectiveness of different lifestyle interventions for overweight people with psychological stress. This paper presents a secondary analysis of the group that received an 8-week mobile ACT intervention. Most of the analyzed 74 participants were female (n=64, 86%). Their median age was 49.6 (interquartile range, IQR 45.4-55.3) years and their mean level of psychological flexibility, measured with the Acceptance and Action Questionnaire II, was 20.4 (95% confidence interval 18.3-22.5). Several usage metrics describing the intensity of use, usage of content, and ways of use were calculated. Linear regression analyses were performed to study the dose-response relationship between usage and the change in psychological flexibility and to identify the usage metrics with strongest association with improvement. Binary logistic regression analyses were further used to assess the role of usage metrics between those who showed improvement in psychological flexibility and those who did not. In addition, associations between usage and baseline participant characteristics were studied. Results The median number of usage sessions was 21 (IQR 11.8-35), the number of usage days was 15 (IQR 9.0-24), and the number of usage weeks was 7.0 (IQR 4.0-8.0). The participants used the mobile app for a median duration of 4.7 (IQR 3.2-7.2) hours and performed a median of 63 (IQR 46-98) exercises. There was a dose-response relationship between usage and the change in psychological flexibility. The strongest associations with psychological flexibility (results adjusted with gender, age, and baseline psychological variables) were found for lower usage of Self as context related exercises (B=0.22, P=.001) and higher intensity of use, described by the number of usage sessions (B=−0.10, P=.01), usage days (B=−0.17, P=.008), and usage weeks (B=−0.73, P=.02), the number of exercises performed (B=−0.02, P=.03), and the total duration of use (B=−0.30, P=.04). Also, higher usage of Acceptance related exercises (B=−0.18, P=.04) was associated with improvement. Active usage was associated with female gender, older age, and not owning a smart mobile phone before the study. Conclusions The results indicated that active usage of a mobile ACT intervention was associated with improved psychological flexibility. Usage metrics describing intensity of use as well as two metrics related to the usage of content were found to be most strongly associated with improvement. Trial Registration ClinicalTrials.gov NCT01738256; https://clinicaltrials.gov/ct2/show/NCT01738256 (Archived by WebCite at http://www.webcitation.org/6iTePjPLL) PMID:27468653

  3. Essays on restructured electricity markets

    NASA Astrophysics Data System (ADS)

    Nicholson, Emma Leah

    This dissertation focuses on the performance of restructured electricity markets in the United States. In chapter 1, I study bidder-specific offer caps ("BSOCs") which are used to mitigate market power in three wholesale electricity markets. The price of electricity is determined through multi-unit uniform price auctions and BSOCs impose an upper limit, which is increasing in marginal cost, on each generator's bid. I apply BSOCs in both the uniform and discriminatory price auctions and characterize the equilibria in a two firm model with stochastic demand. BSOCs unambiguously increase expected production efficiency in the uniform price auction and they can increase the expected profit of the generator with the lower cap. Chapter 2, coauthored with Ramteen Sioshansi, Ph.D., compares two types of uniform price auction formats used in wholesale electricity markets, centrally committed markets and self committed markets. In centrally committed markets, generators submit two-part bids consisting of a fixed startup cost and a variable (per MWh) energy cost, and the auctioneer ensures that no generator operates at a loss. Generators in self committed markets must incorporate their startup costs into their one part energy bids. We derive Nash equilibria for both the centrally and self committed electricity markets in a model with two symmetric generators with nonconvex costs and deterministic demand. Using a numerical example, we demonstrate that if the caps on the bid elements are chosen appropriately, the two market designs are equivalent in terms of generator revenues and settlement costs. Regulators and prominent academic experts believe that electric restructuring polices have stifled investment in new generation capacity. In chapter 3 I seek to determine whether these fears are supported by empirical evidence. I examine both total investment in megawatts and the number of new investments across regions that adopted different electric restructuring policies to determine whether electric restructuring is associated with lower levels of investment in new generation capacity. The estimation results do not prove that total investment levels are lower in regions with restructured electric systems, but I cannot rule the possibility out.

  4. Maximum likelihood analysis of bioassay data from long-term follow-up of two refractory PuO2 inhalation cases.

    PubMed

    Avtandilashvili, Maia; Brey, Richard; James, Anthony C

    2012-07-01

    The U.S. Transuranium and Uranium Registries' tissue donors 0202 and 0407 are the two most highly exposed of the 18 registrants who were involved in the 1965 plutonium fire accident at a defense nuclear facility. Material released during the fire was well characterized as "high fired" refractory plutonium dioxide with 0.32-μm mass median diameter. The extensive bioassay data from long-term follow-up of these two cases were used to evaluate the applicability of the Human Respiratory Tract Model presented by International Commission on Radiological Protection in Publication 66 and its revision proposed by Gregoratto et al. in order to account for the observed long-term retention of insoluble material in the lungs. The maximum likelihood method was used to calculate the point estimates of intake and tissue doses and to examine the effect of different lung clearance, blood absorption, and systemic models on the goodness-of-fit and estimated dose values. With appropriate adjustments, Gregoratto et al. particle transport model coupled with the customized blood absorption parameters yielded a credible fit to the bioassay data for both cases and predicted the Case 0202 liver and skeletal activities measured postmortem. PuO2 particles produced by the plutonium fire are extremely insoluble. About 1% of this material is absorbed from the respiratory tract relatively rapidly, at a rate of about 1 to 2 d (half-time about 8 to 16 h). The remainder (99%) is absorbed extremely slowly, at a rate of about 5 × 10(-6) d (half-time about 400 y). When considering this situation, it appears that doses to other body organs are negligible in comparison to those to tissues of the respiratory tract. About 96% of the total committed weighted dose equivalent is contributed by the lungs. Doses absorbed by these workers' lungs were high: 3.2 Gy to AI and 6.5 Gy to LNTH for Case 0202 (18 y post-intake) and 3.2 Gy to AI and 55.5 Gy to LNTH for Case 0407 (43 y post-intake). This evaluation supports the Gregoratto et al. proposed revision to the ICRP 66 model when considering situations of extremely insoluble particles.

  5. Exploring the impact of customer relational benefit on relationship commitment in health service sectors.

    PubMed

    Weng, Rhay-Hung; Huang, Jin-An; Huang, Ching-Yuan; Huang, Shih-Chang

    2010-01-01

    An increasing number of health service sectors have begun to implement relationship marketing to try to establish long-term relationship with customers. Customer relational benefit has been an important subject for relationship marketing researchers. This study was conducted to investigate how customer relational benefit might influence relationship commitment in health service sectors. The research used a questionnaire survey that retrieved a total number of 403 valid questionnaires. The data were collected by way of personal visits and investigations of outpatients in three regional hospitals in Taiwan. After the reliability and the validity of the questionnaire sample were examined, the data were verified by using hierarchical regression analysis. Results showed that confidence benefit constituted the most pronounced factor for hospital customers. Confidence benefit, social benefit, and special treatment benefit were perceived by customers as the key factors that have a positive influence on relationship commitment. In particular, customers placing greater emphasis on confidence benefit tended to be less willing to establish relationship commitment. When health service managers develop marketing strategies using customer relational benefit, they will still need to enhance customer confidence benefit as one of the main ways of achieving future improvements. In the event where health service managers seek to install resources for establishing and maintaining a good relationship commitment with customers, the crucial factors of social and special treatment benefits should not be ignored when seeking to enhance the customers' perception of confidence benefit.

  6. 24 CFR 886.308 - Maximum total annual contract commitment.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... OF HOUSING AND URBAN DEVELOPMENT (SECTION 8 HOUSING ASSISTANCE PROGRAMS, SECTION 202 DIRECT LOAN PROGRAM, SECTION 202 SUPPORTIVE HOUSING FOR THE ELDERLY PROGRAM AND SECTION 811 SUPPORTIVE HOUSING FOR PERSONS WITH DISABILITIES PROGRAM) SECTION 8 HOUSING ASSISTANCE PAYMENTS PROGRAM-SPECIAL ALLOCATIONS...

  7. 24 CFR 886.308 - Maximum total annual contract commitment.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... OF HOUSING AND URBAN DEVELOPMENT (SECTION 8 HOUSING ASSISTANCE PROGRAMS, SECTION 202 DIRECT LOAN PROGRAM, SECTION 202 SUPPORTIVE HOUSING FOR THE ELDERLY PROGRAM AND SECTION 811 SUPPORTIVE HOUSING FOR PERSONS WITH DISABILITIES PROGRAM) SECTION 8 HOUSING ASSISTANCE PAYMENTS PROGRAM-SPECIAL ALLOCATIONS...

  8. Measuring Effectiveness of TQM Training: An Indian Study.

    ERIC Educational Resources Information Center

    Palo, Sasmita; Padhi, Nayantara

    2003-01-01

    Responses from 372 employees of a steel manufacturer in India were analyzed to measure effectiveness of total quality management training. Training created awareness, built commitment to quality, facilitated teamwork, and enhanced professional standards. However, communication competencies and customer value training needed improvement. (Contains…

  9. Attitudes and Values: Concerns of Middle Managers.

    ERIC Educational Resources Information Center

    Appelbaum, Steven H.

    1978-01-01

    Total individual satisfaction is not the organization's responsibility, but does assume increasing importance when corporate commitment is apparent. Studies have examined employees' values, attitudes, and job satisfaction and often found that individuals feel job dissatisfaction. In remedying this, organizations should develop an interdependent…

  10. A Supply and Demand Management Perspective on the Accelerated Global Introductions of Inactivated Poliovirus Vaccine in a Constrained Supply Market.

    PubMed

    Lewis, Ian; Ottosen, Ann; Rubin, Jennifer; Blanc, Diana Chang; Zipursky, Simona; Wootton, Emily

    2017-07-01

    A total of 105 countries have introduced IPV as of September 2016 of which 85 have procured the vaccine through UNICEF. The Global Eradication and Endgame Strategic Plan 2013-2018 called for the rapid introduction of at least one dose of IPV into routine immunization schedules in 126 all OPV-using countries by the end of 2015. At the time of initiating the procurement process, demand was estimated based on global modeling rather than individual country indications. In its capacity as procurement agency for the Global Polio Eradication Initiative and Gavi, the Vaccine Alliance, UNICEF set out to secure access to IPV supply for around 100 countries. Based on offers received, sufficient supply was awarded to two manufacturers to meet projected routine requirements. However, due to technical issues scaling up vaccine production and an unforecasted demand for IPV use in campaigns to interrupt wild polio virus and to control type 2 vaccine derived polio virus outbreaks, IPV supplies are severely constrained. Activities to stretch supplies and to suppress demand have been ongoing since 2014, including delaying IPV introduction in countries where risks of type 2 reintroduction are lower, implementing the multi-dose vial policy, and encouraging the use of fractional dose delivered intradermally. Despite these efforts, there is still insufficient IPV supply to meet demand. The impact of the supply situation on IPV introduction timelines in countries are the focus of this article, and based on lessons learned with the IPV introductions, it is recommended for future health programs with accelerated scale up of programs, to take a cautious approach on supply commitments, putting in place clear allocation criteria in case of shortages or delays and establishing a communication strategy vis a vis beneficiaries. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  11. Selective effects of two systemic fungicides on soil fungi.

    PubMed

    Abdel-Fattah, H M; Abdel-Kader, M I; Hamida, S

    1982-08-20

    BAS 317 00F was not toxic to the total count of fungi after 2 days but was regularly significantly toxic at the three doses after 5, 20 and 40 days and toxic at the low and the high doses after 80 days. In the agar medium, it was toxic to the counts of total fungi. Aspergillus, A. terreus, Rhizopus oryzae and Mucor racemosus at the high dose. Only the mycelial growth of Trichoderma viride which was significantly inhibited by the three doses when this fungicide was added to the liquid medium. Polyram-Combi induced two effects on the total population of soil fungi. One inhibitory and this was demonstrated almost regularly after 2, 10 and 40 days and the other stimulatory after 80 days of treatment with the low and the high doses. In the agar medium, this fungicide was very toxic to total fungi and to almost all fungal genera and species at the three doses. Several fungi could survive the high dose. In liquid medium, the test fungi showed variable degree of sensitivity and the most sensitive was Gliocladium roseum which was completely eradicated by the three doses.

  12. Total-dose radiation effects data for semiconductor devices: 1985 supplement, volume 1

    NASA Technical Reports Server (NTRS)

    Martin, K. E.; Gauthier, M. K.; Coss, J. R.; Dantas, A. R. V.; Price, W. E.

    1985-01-01

    Steady-state, total-dose radiation test data are provided, in graphic format, for use by electronic designers and other personnel using semiconductor devices in a radiation environment. The data were generated by JPL for various NASA space programs. The document is in two volumes: Volume 1 provides data on diodes, bipolar transistors, field effect transistors, and miscellaneous semiconductor types, and Volume 2 provides total-dose radiation test data on integrated circuits. Volume 1 of this 1985 Supplement contains new total-dose radiation test data generated since the August 1, 1981 release date of the original Volume 1. Publication of Volume 2 of the 1985 Supplement will follow that of Volume 1 by approximately three months.

  13. Determinants of staff commitment to hip protectors in long-term care: A cross-sectional survey.

    PubMed

    Korall, Alexandra M B; Loughin, Thomas M; Feldman, Fabio; Cameron, Ian D; Leung, Pet Ming; Sims-Gould, Joanie; Godin, Judith; Robinovitch, Stephen N

    2018-06-01

    If worn, certain models of hip protectors are highly effective at preventing hip fractures from falls in residents of long-term care, but modest acceptance and adherence have limited the effectiveness of hip protectors. Residents of long-term care are more likely to accept the initial offer of hip protectors and to adhere to recommendations concerning the use of hip protectors when staff are committed to supporting the application of hip protectors. Yet, we know very little about the nature of and factors associated with staff commitment to hip protectors in long-term care. To identify factors associated with staff commitment to hip protectors in long-term care. A cross-sectional survey. Thirteen long-term care homes (total beds = 1816) from a single regional health district in British Columbia, Canada. A convenience sample of 535 paid staff who worked most of their time (>50% of work hours) at a participating long-term care home, for at least one month, and for at least 8 h per week. We excluded six (1.1%) respondents who were unaware of hip protectors. Of the remaining 529 respondents, 90% were female and 55% were health care assistants. Respondents completed the Commitment to Hip Protectors Index to indicate their commitment to hip protectors. We used Bayesian Model Averaging logistic regression to model staff commitment as a function of personal variables, experiences with hip protectors, intraorganizational communication and influence, and organizational context. Staff commitment was negatively related to organizational tenure >20 years (posterior probability = 97%; logistic regression coefficient = -0.28; 95% confidence interval = -0.48, -0.08), and awareness of a padded hip fracture (100%; -0.57; -0.69, -0.44). Staff commitment was positively related to the existence of a champion of hip protectors within the home (100%; 0.24; 0.17, 0.31), perceived quality of intraorganizational communication (100%; 0.04; 0.02, 0.05), extent of mutual respect between residents and staff and perceived contribution to quality of life of the residents they serve (100%; 0.10; 0.05, 0.15), and frequency of transformational leadership practices by respondents' primary supervisors (100%; 0.01; 0.01, 0.02). We provide novel insight into the factors governing staff commitment to hip protectors in long-term care. Targeting of these factors could improve acceptance and adherence with hip protectors, thereby contributing to enhanced effectiveness of hip protectors to prevent hip fractures in long-term care. Copyright © 2018. Published by Elsevier Ltd.

  14. 241Am Ingrowth and Its Effect on Internal Dose

    DOE PAGES

    Konzen, Kevin

    2016-07-01

    Generally, plutonium has been manufactured to support commercial and military applications involving heat sources, weapons and reactor fuel. This work focuses on three typical plutonium mixtures, while observing the potential of 241Am ingrowth and its effect on internal dose. The term “ingrowth” is used to describe 241Am production due solely from the decay of 241Pu as part of a plutonium mixture, where it is initially absent or present in a smaller quantity. Dose calculation models do not account for 241Am ingrowth unless the 241Pu quantity is specified. This work suggested that 241Am ingrowth be considered in bioassay analysis when theremore » is a potential of a 10% increase to the individual’s committed effective dose. It was determined that plutonium fuel mixtures, initially absent of 241Am, would likely exceed 10% for typical reactor grade fuel aged less than 30 years; however, heat source grade and aged weapons grade fuel would normally fall below this threshold. In conclusion, although this work addresses typical plutonium mixtures following separation, it may be extended to irradiated commercial uranium fuel and is expected to be a concern in the recycling of spent fuel.« less

  15. MPC and ALI: their basis and their comparison

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kennedy, W.E. Jr.; Watson, E.C.

    Radiation protection regulations in the United States have evolved from the recommendations of the International Commission on Radiological Protection (ICRP) and the National Council on Radiation Protection and Measurements (NCRP). In 1959, the ICRP issued Publication 2 which contained specific recommendations on dose rate limits, permissible body burdens, metabolic data for radionuclides, and maximum permissible concentrations (MPC) in air or water. Over the next 20 years, new information became available concerning the effects of radiation, the uptake and retention of radionuclides, and the radioactive decay schemes of parent radionuclides. To include this newer information, the ICRP issued Publication 30 inmore » 1978 to supersede Publication 2. One of the secondary limits defined in Publication 30 is the annual limit of intake (ALI). Radionuclide specific ALI values are intended to replace MPC values in determining whether or not ambient air and water concentrations are sufficiently low to maintain the dose to workers within accepted dose rate limits. In this paper, we discuss the derivation of MPC and ALI values, compare inhalation committed dose equivalent factors derived from ICRP Publications 2 and 30, and discuss the practical implications of using either MPC or ALI in determining compliance with occupational exposure limits. 6 references.« less

  16. Total Ionizing Dose Test Report for the UC1823A Pulse Width Modulator

    NASA Technical Reports Server (NTRS)

    Chen, Dakai; Forney, James

    2017-01-01

    The purpose of this study is to examine the total ionizing dose susceptibility for the UC1823A pulse width modulator manufactured by Texas Instruments, Inc. The part is suspected to be vulnerable to enhanced low dose rate sensitivity (ELDRS).

  17. ELDRS Characterization for a Very High Dose Mission

    NASA Technical Reports Server (NTRS)

    Harris, Richard D.; McClure, Steven S.; Rax, Bernard G.; Kenna, Aaron J.; Thorbourn, Dennis O.; Clark, Karla B.; Yan, Tsun-Yee

    2010-01-01

    Evaluation of bipolar linear parts which may have Enhanced Low Dose Rate Sensitivity (ELDRS) is problematic for missions that have very high dose radiation requirements. The accepted standards for evaluating parts that display ELDRS require testing at a very low dose rate which could be prohibitively long for very high dose missions. In this work, a methodology for ELDRS characterization of bipolar parts for mission doses up to 1 Mrad(Si) is evaluated. The procedure employs an initial dose rate of 0.01 rad(Si)/s to a total dose of 50 krad(Si) and then changes to 0.04 rad(Si)/s to a total dose of 1 Mrad(Si). This procedure appears to work well. No change in rate of degradation with dose has been observed when the dose rate is changed from 0.01 to 0.04 rad(Si)/s. This is taken as an indication that the degradation due to the higher dose rate is equivalent to that at the lower dose rate at the higher dose levels, at least for the parts studied to date. In several cases, significant parameter degradation or functional failure not observed at HDR was observed at fairly high total doses (50 to 250 krad(Si)) at LDR. This behavior calls into question the use of dose rate trend data and enhancement factors to predict LDR performance.

  18. Importance of relationship quality and communication on foodservice for the elderly.

    PubMed

    Seo, Sunhee; Back, Ki Joon; Shanklin, Carol W

    2011-02-01

    In order to promote foodservice for the elderly, foodservice managers in Continuing Care Retirement Communities (CCRCs) must identify the main factors to enhance the satisfaction and behavioral intentions with food service. The purpose of this study was to investigate the relationships between relationship quality (consisting of trust, commitment, and satisfaction) and communication in the formation of elderly's behavioral intentions with food services at CCRCs. A survey was administered to residents in two CCRCs and a total of 327 residents participated. A tested structural equation model exhibited good model fit and explanatory power of the study construct. Satisfaction directly influenced word-of-mouth and service quality has an influence on commitment. Commitment was a significant determinant of behavioral intentions to eat more often in the dining room. Also, communication showed positive association with trust. The results provided strong evidence for the importance of satisfaction and communication as a consequence of relationship marketing efforts. Suggestions for future research to better understand the elderly' behavioral intention judgments were given.

  19. Importance of relationship quality and communication on foodservice for the elderly

    PubMed Central

    Back, Ki Joon; Shanklin, Carol W.

    2011-01-01

    In order to promote foodservice for the elderly, foodservice managers in Continuing Care Retirement Communities (CCRCs) must identify the main factors to enhance the satisfaction and behavioral intentions with food service. The purpose of this study was to investigate the relationships between relationship quality (consisting of trust, commitment, and satisfaction) and communication in the formation of elderly's behavioral intentions with food services at CCRCs. A survey was administered to residents in two CCRCs and a total of 327 residents participated. A tested structural equation model exhibited good model fit and explanatory power of the study construct. Satisfaction directly influenced word-of-mouth and service quality has an influence on commitment. Commitment was a significant determinant of behavioral intentions to eat more often in the dining room. Also, communication showed positive association with trust. The results provided strong evidence for the importance of satisfaction and communication as a consequence of relationship marketing efforts. Suggestions for future research to better understand the elderly' behavioral intention judgments were given. PMID:21487500

  20. Psychological and organizational impact of bullying over and above negative affectivity: a survey of two nursing contexts.

    PubMed

    Rodwell, John; Demir, Defne; Steane, Peter

    2013-06-01

    Limited research exists on the impact of bullying across psychological and/or organizationally orientated outcomes for nurses working within different nursing contexts. Research that has explored these outcomes has not considered the potential confounding effects of negative affectivity (NA). This study's aim was to examine the extent hospital and aged care nurses are impacted by bullying on these outcomes, while considering NA. A total of 267 hospital nurses/midwives and 168 aged care nurses from an Australian healthcare organization responded to a survey. The results revealed hospital nurses/midwives who experienced bullying reported higher levels of psychological distress, as well as lower commitment and job satisfaction levels. Aged care nurses who experienced bullying reported lower levels of well-being and commitment. NA was a significant covariate for most analyses. Thus, nurses across these contexts are affected by bullying in relation to psychological and organizational-orientated outcomes over and above the effects of NA, particularly for commitment. © 2013 Wiley Publishing Asia Pty Ltd.

  1. Low-energy electron effects on tensile modulus and infrared transmission properties of a polypyromellitimide film

    NASA Technical Reports Server (NTRS)

    Ferl, J. E.; Long, E. R., Jr.

    1981-01-01

    Infrared (IR) spectroscopy and tensile modulus testing were used to evaluate the importance of experimental procedure on changes in properties of pyromellitic dianhydride-p,p prime-oxydianiline film exposed to electron radiation. The radiation exposures were accelerated, approximate equivalents to the total dose expected for a 30 year mission in geosynchronous Earth orbit. The change in the tensile modulus depends more on the dose rate and the time interval between exposure and testing than on total dose. The IR data vary with both total dose and dose rate. A threshold dose rate exists below which reversible radiation effects on the IR spectra occur. Above the threshold dose rate, irreversible effects occur with the appearance of a new band. Post-irradiation and in situ IR absorption bands are significantly different. It is suggested that the electron radiation induced metastable, excites molecular states.

  2. Evaluating the technique of using inhalation device in COPD and bronchial asthma patients.

    PubMed

    Arora, Piyush; Kumar, Lokender; Vohra, Vikram; Sarin, Rohit; Jaiswal, Anand; Puri, M M; Rathee, Deepti; Chakraborty, Pitambar

    2014-07-01

    In asthma management, poor handling of inhalation devices and wrong inhalation technique are associated with decreased medication delivery and poor disease control. The key to overcome the drawbacks in inhalation technique is to make patients familiar with issues related to correct use and performance of these medical devices. The objective of this study was to evaluate and analyse technique of use of the inhalation device used by patients of COPD and Bronchial Asthma. A total of 300 cases of BA or COPD patients using different types of inhalation devices were included in this observational study. Data were captured using a proforma and were analysed using SPSS version 15.0. Out of total 300 enrolled patients, 247 (82.3%) made at least one error. Maximum errors observed in subjects using MDI (94.3%), followed by DPI (82.3%), MDI with Spacer (78%) while Nebulizer users (70%) made least number of errors (p = 0.005). Illiterate patients showed 95.2% error while post-graduate and professionals showed 33.3%. This difference was statistically significant (p < 0.001). Self-educated patients committed 100% error, while those trained by a doctor made 56.3% error. Majority of patients using inhalation devices made errors while using the device. Proper education to patients on correct usage may not only improve control of the symptoms of the disease but might also allow dose reduction in long term. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. ALARA implementation throughout project life cycle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haynes, M.J.

    1995-03-01

    A strength of radiation protection programs generally has been endorsement and application of the ALARA principle. In Ontario Hydro, which currently operates 20 commercial size nuclear units, great strides have been made in the last three decades in reducing occupational radiation exposure per unit of electricity generated. This paper will discuss specific applications of elements of the overall ALARA program which have most contributed to dose reduction as the nuclear program has expanded. This includes such things as management commitment, ALARA application in the design phase and major rehabilitation work, the benefits of the self protection concept, a specific examplemore » of elimination (or reduction) of the source term and the importance of dose targets. Finally, it is concluded that the major opportunities for further improvements may lie in the area of information management.« less

  4. Creative Marketing for the 80's.

    ERIC Educational Resources Information Center

    Cox, Timothy C.

    To compete for dwindling numbers of traditional college-aged students and to attract non-traditional clientele, community colleges are becoming increasingly involved in marketing. Commitment to a total marketing concept requires institutional research to identify the college's mission, potential students, and the competition. Those in charge of…

  5. Donation FAQs

    MedlinePlus

    ... to-six-week period. This does not include travel time, which is defined by air travel and staying overnight in a hotel. Nearly 40% of donors will travel during the donation process. Marrow and PBSC donation require about the same total time commitment. What if I have medical complications related ...

  6. Single-Cell RNA-Sequencing Reveals a Continuous Spectrum of Differentiation in Hematopoietic Cells.

    PubMed

    Macaulay, Iain C; Svensson, Valentine; Labalette, Charlotte; Ferreira, Lauren; Hamey, Fiona; Voet, Thierry; Teichmann, Sarah A; Cvejic, Ana

    2016-02-02

    The transcriptional programs that govern hematopoiesis have been investigated primarily by population-level analysis of hematopoietic stem and progenitor cells, which cannot reveal the continuous nature of the differentiation process. Here we applied single-cell RNA-sequencing to a population of hematopoietic cells in zebrafish as they undergo thrombocyte lineage commitment. By reconstructing their developmental chronology computationally, we were able to place each cell along a continuum from stem cell to mature cell, refining the traditional lineage tree. The progression of cells along this continuum is characterized by a highly coordinated transcriptional program, displaying simultaneous suppression of genes involved in cell proliferation and ribosomal biogenesis as the expression of lineage specific genes increases. Within this program, there is substantial heterogeneity in the expression of the key lineage regulators. Overall, the total number of genes expressed, as well as the total mRNA content of the cell, decreases as the cells undergo lineage commitment. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  7. A comprehensive study on the relationship between the image quality and imaging dose in low-dose cone beam CT

    NASA Astrophysics Data System (ADS)

    Yan, Hao; Cervino, Laura; Jia, Xun; Jiang, Steve B.

    2012-04-01

    While compressed sensing (CS)-based algorithms have been developed for the low-dose cone beam CT (CBCT) reconstruction, a clear understanding of the relationship between the image quality and imaging dose at low-dose levels is needed. In this paper, we qualitatively investigate this subject in a comprehensive manner with extensive experimental and simulation studies. The basic idea is to plot both the image quality and imaging dose together as functions of the number of projections and mAs per projection over the whole clinically relevant range. On this basis, a clear understanding of the tradeoff between the image quality and imaging dose can be achieved and optimal low-dose CBCT scan protocols can be developed to maximize the dose reduction while minimizing the image quality loss for various imaging tasks in image-guided radiation therapy (IGRT). Main findings of this work include (1) under the CS-based reconstruction framework, image quality has little degradation over a large range of dose variation. Image quality degradation becomes evident when the imaging dose (approximated with the x-ray tube load) is decreased below 100 total mAs. An imaging dose lower than 40 total mAs leads to a dramatic image degradation, and thus should be used cautiously. Optimal low-dose CBCT scan protocols likely fall in the dose range of 40-100 total mAs, depending on the specific IGRT applications. (2) Among different scan protocols at a constant low-dose level, the super sparse-view reconstruction with the projection number less than 50 is the most challenging case, even with strong regularization. Better image quality can be acquired with low mAs protocols. (3) The optimal scan protocol is the combination of a medium number of projections and a medium level of mAs/view. This is more evident when the dose is around 72.8 total mAs or below and when the ROI is a low-contrast or high-resolution object. Based on our results, the optimal number of projections is around 90 to 120. (4) The clinically acceptable lowest imaging dose level is task dependent. In our study, 72.8 mAs is a safe dose level for visualizing low-contrast objects, while 12.2 total mAs is sufficient for detecting high-contrast objects of diameter greater than 3 mm.

  8. Total quality management and nursing: a shared vision.

    PubMed

    Morey, W

    1996-09-01

    The application of the Total Quality Management (TQM) philosophy within the health care sector would enhance the development of nursing power, leadership and knowledge. TQM challenges conventional management techniques as it requires a participative management style in order to be effective. There are many potential benefits for nurses, when quality assurance monitoring within a hierarchical management structure, is replaced with a focus on continuous quality improvement by every member of staff. These benefits are described within the context of both organisational and personal commitment to Total Quality Management.

  9. The use of mobile phones to deliver acceptance and commitment therapy in the prevention of mother-child HIV transmission in Nigeria.

    PubMed

    Ishola, A G; Chipps, J

    2015-12-01

    The objective of this study was to determine if introducing acceptance and commitment therapy in the prevention of mother to child HIV transmission (PMTCT) programme using weekly mobile phone messages would result in improved mental health status of HIV-positive, pregnant women in Nigeria. We used a Solomon four-group (two intervention and two control groups) randomised design. The study population was 144 randomly selected, HIV-positive pregnant women attending four randomly selected PMTCT centres in Nigeria. The intervention groups were exposed to one session of acceptance and commitment therapy with weekly value-based health messages sent by mobile phone for three months during pregnancy. The control groups received only post-HIV test counselling. A total of 132 participants (33 per site) were enrolled in the study from the two intervention and two control sites. In the pre-tests, the intervention and control groups did not differ significantly with regard to demographics. Evaluation of the pre- and post-tests of the intervention group indicated significantly higher Action and Acceptance Questionnaire (AAQ-II) scores. The introduction of a mobile phone acceptance and commitment therapy programme may result in greater psychological flexibility in women diagnosed with HIV. © The Author(s) 2015.

  10. Gaining and maintaining commitment to large-scale change in healthcare organizations.

    PubMed

    Narine, L; Persaud, D D

    2003-08-01

    Healthcare administrators have sought to improve the quality of healthcare services by using organizational change as a lever. Unfortunately, evaluations of organizational change efforts in areas such as total quality management (TQM), continuous quality improvement (CQI), and organizational restructuring have indicated that these change programmes have not fulfilled their promise in improving service delivery. Furthermore, there are no easy answers as to why so many large-scale change programmes are unsuccessful. The aim of this analysis is to provide insights into practices that may be utilized to improve the chances of successful change management. It is proposed that in order to effect change, implementers must first gain commitment to the change. This is done by ensuring organizational readiness for change, surfacing dissatisfaction with the present state, communicating a clear vision of the proposed change, promoting participation in the change effort, and developing a clear and consistent communication plan. However gaining commitment is not enough. Many change programmes have been initially perceived as being successful but long-term success has been elusive. Therefore, maintaining commitment during the uncertainty associated with the transition period is imperative. This can be done by successfully managing the transition using action steps such as consolidating change using feedback mechanisms and making the change a permanent part of the organization's culture.

  11. Decorporation Approach after Rat Lung Contamination with Plutonium: Evaluation of the Key Parameters Influencing the Efficacy of a Protracted Chelation Treatment.

    PubMed

    Grémy, Olivier; Coudert, Sylvie; Renault, Daniel; Miccoli, Laurent

    2017-11-01

    While the efficacy of a protracted zinc (Zn)- or calcium (Ca)-diethylenetriaminepentaacetic acid (DTPA) treatment in reducing transuranic body burden has already been demonstrated, questions about therapeutic variables remain. In response to this, we designed animal experiments primarily to assess both the effect of fractionation of a given dose and the effect of the frequency of dose fraction, with the same total dose. In our study, rats were contaminated intravenously with plutonium (Pu) then treated several days later with Ca-DTPA given at once or in various split-dose regimens cumulating to the same total dose and spread over several days. Similar efficacies were induced by the injection of the total dose or by splitting the dose in several smaller doses, independent of the number of doses and the dose level per injection. In a second study, rats were pulmonary contaminated, and three weeks later they received a Ca-DTPA dose 11-fold higher than the maximal daily recommended dose, administered either as a single bolus or as numerous multiple injections cumulating to the same dose, based on different injection frequency schedules. Independent of frequency schedule, the various split-dose regimens spread over weeks/months were as efficient as single delivery of the total dose in mobilizing lung plutonium, and had a therapeutic advantage for removal of retained hepatic and bone plutonium burdens. We concluded that cumulative dose level was a therapeutic variable of greater importance than the distribution of split doses for the success of a repeated treatment regimen on retained tissue plutonium. In addition, pulmonary administration of clodronate, which aims at killing alveolar macrophages and subsequently releasing their plutonium content, and which is associated with a continuous Ca-DTPA infusion regimen, suggested that the efficacy of injected Ca-DTPA in decorporating lung deposit is limited, due to its restricted penetration into alveolar macrophages and not because plutonium, as a physicochemical form, is unavailable for chelation.

  12. [Prevention of adriamycin-induced alopecia by scalp hypothermia with a deep-frozen Duncool-Cap].

    PubMed

    Konishi, Y; Kuroki, T

    1988-11-01

    In order to prevent Adriamycin (ADM)-induced alopecia, scalp hypothermia with a Duncool-Cap frozen in a freezer at -70 degrees C was carried out. Of the 18 patients studied, one patient given total ADM doses of 240 mg developed alopecia of moderate degree, and another patient treated with ADM at a dose level of 50 mg developed mild alopecia. Alopecia could be almost completely prevented in 10 of the 11 patients given total ADM doses of 100 mg or less, and in 6 of the 7 patients given total doses of 200 mg or more.

  13. Comparison of different glucocorticoid regimens in the management of classical congenital adrenal hyperplasia due to 21-hydroxylase deficiency.

    PubMed

    Ajish, T P; Praveen, V P; Nisha, B; Kumar, Harish

    2014-11-01

    There are recommendations regarding the total dose of hydrocortisone to be administered in the treatment of classical congenital adrenal hyperplasia (CAH) to achieve the twin objectives of glucocorticoid replacement and control of hyperandrogenism. However, there is evidence gap regarding the breakup, timing and type of the steroid regimen. Efficacy of three different glucocorticoid regimens having the same total dose of steroid, differing in either the timing or type of evening steroid administered, in achieving biochemical control of the disease was assessed. The study was done in 13 prepubertal children with classical CAH over a 6-month period with 2 months devoted to each regimen. We used a prospective cross-over design using 10-15 mg/m(2) total dose of hydrocortisone. Two-fifths of the total dose of hydrocortisone was administered in the morning and one-fifth of the total dose was administered at noon in all the regimens. The regimens differed in the timing of the evening dose of hydrocortisone, 06.00-07.00 pm in regimen 1 and 09.00-10.00 pm in regimen 2. The third regimen had the evening dose of hydrocortisone replaced by an equivalent dose of prednisolone suspension which was administered at 10.00 pm. Serum 17-hydroxyprogesterone and testosterone levels were compared to assess the efficacy of treatment regimens. The three different regimens were found to be similar in their ability to control 17-hydroxyprogesterone and testosterone levels. The percentage of patients with predefined criteria for biochemically controlled disease was similar in all the three regimens. However, there was a trend toward better control of 17-hydroxyprogesterone levels in patients receiving evening dose of prednisolone. There is no significant advantage in administering the hydrocortisone dose late at night in patients with classical CAH.

  14. Long-term erythemal UV doses at Sodankylä estimated using total ozone, sunshine duration and snow depth

    NASA Astrophysics Data System (ADS)

    Lindfors, A. V.; Arola, A.; Kaurola, J.; Taalas, P.; Svenøe, T.

    2003-04-01

    A method for estimating daily erythemal UV doses using total ozone, sunshine duration and snow depth has been developed. The method consists of three steps: (1) daily clear-sky UV doses were simulated using the UVSPEC radiative transfer program, with daily values of total ozone as input data, (2) an empirical relationship was sought between the simulated clear-sky UV doses, the measured UV doses and the duration of bright sunshine, (3) daily erythemal UV doses were estimated using this relationship. The method accounts for the varying surface albedo by dividing the period of interest into winter and summer days, depending on the snow depth. Using this method, the daily erythemal UV doses at Sodankylä were estimated for the period 1950--99. This was done using Tromsø's total ozone together with Sodankylä's own sunshine duration and snow depth as input data. Although the method is fairly simple, the results are in good agreement, even on the daily scale, with the UV radiation measured with the Brewer spectrophotometer at Sodankylä. Statistically significant increasing trends in erythemal UV doses of a few percents per decade over the period 1950--99 were found for March and April, suggesting a connection to the stratospheric ozone depletion. For July, on the other hand, a significant decreasing trend of about 3% per decade, supported by the changes in both total ozone and sunshine duration, was found. The produced data set of erythemal UV doses is the longest time series of estimated UV known to the authors.

  15. The Impact of Dose Rate on the Accuracy of Step-and-Shoot Intensity-modulated Radiation Therapy Quality Assurance Using Varian 2300CD.

    PubMed

    Njeh, Christopher F; Salmon, Howard W; Schiller, Claire

    2017-01-01

    Intensity-modulated radiation therapy (IMRT) delivery using "step-and-shoot" technique on Varian C-Series linear accelerator (linac) is influenced by the communication frequency between the multileaf collimator and linac controllers. Hence, the dose delivery accuracy is affected by the dose rate. Our aim was to quantify the impact of using two dose rates on plan quality assurance (QA). Twenty IMRT patients were selected for this study. The plan QA was measured at two different dose rates. A gamma analysis was performed, and the degree of plan modulation on the QA pass rate was also evaluated in terms of average monitor unit per segment (MU/segment) and the total number of segments. The mean percentage gamma pass rate of 94.9% and 93.5% for 300 MU/min and 600 MU/min dose rate, respectively, was observed. There was a significant ( P = 0.001) decrease in percentage gamma pass rate when the dose rate was increased from 300 MU/min to 600 MU/min. There was a weak, but significant association between the percentage pass rate at both dose rate and total number of segments. The total number of MU was significantly correlated to the total number of segments ( r = 0.59). We found a positive correlation between the percentage pass rate and mean MU/segment, r = 0.52 and r = 0.57 for 300 MU/min and 600 MU/min, respectively. IMRT delivery using step-and-shoot technique on Varian 2300CD is impacted by the dose rate and the total amount of segments.

  16. Confidence Level Based Approach to Total Dose Specification for Spacecraft Electronics

    NASA Technical Reports Server (NTRS)

    Xapsos, M. A.; Stauffer, C.; Phan, A.; McClure, S. S.; Ladbury, R. L.; Pellish, J. A.; Campola, M. J.; Label, K. A.

    2017-01-01

    A confidence level based approach to total dose radiation hardness assurance is presented for spacecraft electronics. It is applicable to both ionizing and displacement damage dose. Results are compared to the traditional approach that uses radiation design margin and advantages of the new approach are discussed.

  17. Total Ionizing Dose Effects in Bipolar and BiCMOS Devices

    NASA Technical Reports Server (NTRS)

    Chavez, Rosa M.; Rax, Bernard G.; Scheick, Leif Z.; Johnston, Allan H.

    2005-01-01

    This paper describes total ionizing dose (TID) test results performed at JPL. Bipolar and BiCMOS device samples were tested exhibiting significant degradation and failures at different irradiation levels. Linear technology which is susceptible to low-dose dependency (ELDRS) exhibited greater damage for devices tested under zero bias condition.

  18. Radioactivity measurements on migrating birds (Turdus philomelos) captured in the Comunidad Valenciana (Spain).

    PubMed

    Navarro, E; Roldán, C; Cervera, J; Ferrero, J L

    1998-01-19

    The radionuclides 137Cs, 134Cs and 90Sr have been measured in edible tissues and bones of migratory birds (song-thrushes, Turdus philomelos) from central and northern Europe and captured in the Comunidad Valenciana, Spain in the 1994 autumn-winter season. Eight years after the Chernobyl accident, extensive agricultural lands in Europe are still contaminated and this study shows that there was a transfer of radioactive isotopes to the captured migratory song-thrushes. The whole-body dose commitment to humans consuming these birds is estimated.

  19. Effects of sublethal fenitrothion ingestion on cholinesterase inhibition, standard metabolism, thermal preference, and prey-capture ability in the Australian central bearded dragon (Pogona vitticeps, Agamidae).

    PubMed

    Bain, David; Buttemer, William A; Astheimer, Lee; Fildes, Karen; Hooper, Michael J

    2004-01-01

    The central bearded dragon (Pogona vitticeps) is a medium-sized lizard that is common in semiarid habitats in Australia and that potentially is at risk of fenitrothion exposure from use of the chemical in plague locust control. We examined the effects of single sublethal doses of this organophosphate (OP; low dose = 2.0 mg/kg; high dose = 20 mg/kg; control = vehicle alone) on lizard thermal preference, standard metabolic rate, and prey-capture ability. We also measured activities of plasma total cholinesterase (ChE) and acetylcholinesterase before and at 0, 2, 8, 24, 120, and 504 h after OP dosing. Predose plasma total ChE activity differed significantly between sexes and averaged 0.66 +/- 0.06 and 0.45 +/- 0.06 micromol/min/ml for males and females, respectively. Approximately 75% of total ChE activity was attributable to butyrylcholinesterase. Peak ChE inhibition reached 19% 2 h after OP ingestion in the low-dose group, and 68% 8 h after ingestion in high-dose animals. Neither OP doses significantly affected diurnal body temperature, standard metabolic rate, or feeding rate. Plasma total ChE levels remained substantially depressed up to 21 d after dosing in the high-dose group, making this species a useful long-term biomonitor of OP exposure in its habitat.

  20. Automated System Marketplace 1988: Focused on Fulfilling Commitments.

    ERIC Educational Resources Information Center

    Walton, Robert A.; Bridge, Frank R.

    1989-01-01

    Analyzes trends in the library automation marketplace. Market shares for online vendors are examined in terms of total installations, academic libraries, public libraries, revenues, differently sized systems, and foreign installations. Hardware availability, operating systems, and interfaces with MARC are also discussed for each vendor. A source…

  1. Benefits of online in vivo dosimetry for single-fraction total body irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eaton, David J., E-mail: davideaton@nhs.net; Warry, Alison J.; Trimble, Rachel E.

    Use of a patient test dose before single-fraction total body irradiation (TBI) allows review of in vivo dosimetry and modification of the main treatment setup. However, use of computed tomography (CT) planning and online in vivo dosimetry may reduce the need for this additional step. Patients were treated using a supine CT-planned extended source-to-surface distance (SSD) technique with lead compensators and bolus. In vivo dosimetry was performed using thermoluminescent dosimeters (TLDs) and diodes at 10 representative anatomical locations, for both a 0.1-Gy test dose and the treatment dose. In total, 28 patients were treated between April 2007 and July 2013,more » with changes made in 10 cases (36%) following test dose results. Overall, 98.1% of measured in vivo treatment doses were within 10% of the prescribed dose, compared with 97.0% of test dose readings. Changes made following the test dose could have been applied during the single-fraction treatment itself, assuming that the dose was delivered in subportions and online in vivo dosimetry was available for all clinically important anatomical sites. This alleviates the need for a test dose, saving considerable time and resources.« less

  2. Fast method for in-flight estimation of total dose from protons and electrons using RADE Minstrument on JUICE

    NASA Astrophysics Data System (ADS)

    Hajdas, Wojtek; Mrigakshi, Alankrita; Xiao, Hualin

    2017-04-01

    The primary concern of the ESA JUICE mission to Jupiter is the harsh particle radiation environment. Ionizing particles introduce radiation damage by total dose effects, displacement damages or single events effects. Therefore, both the total ionizing dose and the displacement damage equivalent fluence must be assessed to alert spacecraft and its payload as well as to quantify radiation levels for the entire mission lifetime. We present a concept and implementations steps for simplified method used to compute in flight a dose rate and total dose caused by protons. We also provide refinement of the method previously developed for electrons. The dose rates values are given for predefined active volumes located behind layers of materials with known thickness. Both methods are based on the electron and proton flux measurements provided by the Electron and Proton Detectors inside the Radiation Hard Electron Monitor (RADEM) located on-board of JUICE. The trade-off between method accuracy and programming limitations for in-flight computations are discussed. More comprehensive and precise dose rate computations based on detailed analysis of all stack detectors will be made during off-line data processing. It will utilize full spectral unfolding from all RADEM detector subsystems.

  3. Image-guided total marrow and total lymphatic irradiation using helical tomotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schultheiss, Timothy E.; Wong, Jeffrey; Liu, An

    2007-03-15

    Purpose: To develop a treatment technique to spare normal tissue and allow dose escalation in total body irradiation (TBI). We have developed intensity-modulated radiotherapy techniques for the total marrow irradiation (TMI), total lymphatic irradiation, or total bone marrow plus lymphatic irradiation using helical tomotherapy. Methods and Materials: For TBI, we typically use 12 Gy in 10 fractions delivered at an extended source-to-surface distance (SSD). Using helical tomotherapy, it is possible to deliver equally effective doses to the bone marrow and lymphatics while sparing normal organs to a significant degree. In the TMI patients, whole body skeletal bone, including the ribsmore » and sternum, comprise the treatment target. In the total lymphatic irradiation, the target is expanded to include the spleen and major lymph node areas. Sanctuary sites for disease (brain and testes) are included when clinically indicated. Spared organs include the lungs, esophagus, parotid glands, eyes, oral cavity, liver, kidneys, stomach, small and large intestine, bladder, and ovaries. Results: With TBI, all normal organs received the TBI dose; with TMI, total lymphatic irradiation, and total bone marrow plus lymphatic irradiation, the visceral organs are spared. For the first 6 patients treated with TMI, the median dose to organs at risk averaged 51% lower than would be achieved with TBI. By putting greater weight on the avoidance of specific organs, greater sparing was possible. Conclusion: Sparing of normal tissues and dose escalation is possible using helical tomotherapy. Late effects such as radiation pneumonitis, veno-occlusive disease, cataracts, neurocognitive effects, and the development of second tumors should be diminished in severity and frequency according to the dose reduction realized for the organs at risk.« less

  4. Single-dose radiation therapy for prevention of heterotopic ossification after total hip arthroplasty

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Healy, W.L.; Lo, T.C.; Covall, D.J.

    1990-12-01

    Single-dose radiation therapy was prospectively evaluated for its efficacy in prevention of heterotopic ossification in patients at high risk after total hip arthroplasty. Thirty-one patients (34 hips) were treated between 1981 and 1988. Risk factors for inclusion in the protocol included prior evidence of heterotopic ossification, ankylosing spondylitis, and diffuse idiopathic skeletal hyperostosis. Patients with hypertrophic osteoarthritis or traumatic arthritis with osteophytes were not included. Operations on 34 hips included 19 primary total and 11 revision total hip arthroplasties and 4 excisions of heterotopic ossification. All patients received radiotherapy to the hip after operation with a single dose of 700more » centigray. Radiotherapy is recommended on the first postoperative day. After this single-dose radiation treatment, no patient had clinically significant heterotopic ossification. Recurrent disease developed in two hips (6%), as seen on radiography (grades 2 and 3). This series documents a 100% clinical success rate and a 94% radiographic success rate in preventing heterotopic ossification in patients at high risk after total hip arthroplasty. Single-dose radiotherapy is as effective as other radiation protocols in preventing heterotopic ossification after total hip arthroplasty. It is less expensive and easier to administer than multidose radiotherapy.« less

  5. Evaluation of total-dose iron sucrose infusions in patients with iron deficiency anemia.

    PubMed

    Wall, Geoffrey C; Pauly, Rebecca A

    2008-01-15

    The safety and efficacy of a total-dose iron sucrose infusion protocol used in a large, tertiary care teaching hospital were studied. Nondialysis-dependent patients ages 18 years or older who received > or =250 mg of iron sucrose as a single i.v. infusion between January 2005 and January 2007 were eligible for study inclusion. The protocol for total-dose iron sucrose infusion was the same for all patients. The total dose of iron sucrose for each patient was calculated using an equation that included the desired hemoglobin (Hb) value, observed Hb level, ideal body weight, and sex. The calculated dose was divided into portions, rounded to the nearest 250 mg, and administered over four hours every other day. Outcomes measured included Hb, transferrin saturation, and serum ferritin values. A total of 26 patients met the inclusion criteria. The mean +/- S.D. Hb concentration before total-dose iron sucrose infusion was 9.37 +/- 0.9 g/dL, and the mean +/- S.D. corpuscular volume was 75 +/- 7.1 mum(3). The mean +/- S.D. postinfusion Hb concentration for 19 patients for whom follow-up Hb levels were available was 11.4 +/- 1.2 g/dL, significantly higher than the 9.45 +/- 0.8 g/dL measured before the first infusion (p = 0.03). No significant adverse effects were reported in 47 of 49 infusions, with 2 patients experiencing mild nausea. A treatment protocol consisting of alternate-day total-dose iron sucrose infusions was well tolerated and appeared to be effective in improving Hb concentrations in patients with iron deficiency anemia and without chronic kidney disease.

  6. Evaluation of dose variation during total skin electron irradiation using thermoluminescent dosimeters.

    PubMed

    Weaver, R D; Gerbi, B J; Dusenbery, K E

    1995-09-30

    To determine acceptable dose variation using thermoluminescent dosimeters (TLD) in the treatment of Mycosis Fungoides with total skin electron beam (TSEB) irradiation. From 1983 to 1993, 22 patients were treated with total skin electron beam therapy in the standing position. A six-field technique was used to deliver 2 Gy in two days, treating 4 days per week, to a total dose of 35 to 40 Gy using a degraded 9 MeV electron beam. Thermoluminescent dosimeters were placed on several locations of the body and the results recorded. The variations in these readings were analyzed to determine normal dose variation for various body locations during TSEB. The dose to flat surfaces of the body was essentially the same as the dose to the prescription point. The dose to tangential surfaces was within +/- 10% of the prescription dose, but the readings showed much more variation (up to 24%). Thin areas of the body showed large deviations from the prescription dose along with a large amount of variation in the readings (up to 22%). Special areas of the body, such as the perineum and eyelid, showed large deviations from the prescription dose with very large (up to 40%) variations in the readings. The TLD results of this study will be used as a quality assurance check for all new patients treated with TSEB. The results of the TLDs will be compared with this baseline study to determine if the delivered dose is within acceptable ranges. If the TLD results fall outside the acceptable limits established above, then the patient position can be modified or the technique itself evaluated.

  7. Self esteem and organizational commitment among health information management staff in tertiary care hospitals in Tehran.

    PubMed

    Sadoughi, Farahnaz; Ebrahimi, Kamal

    2014-12-12

    Self esteem (SE) and organizational commitment (OC)? have significant impact on the quality of work life. This study aims to gain a better understanding of the relationships between SE and OC among health information management staff in tertiary care hospitals in Tehran (Iran). This was a descriptive correlational and cross sectional study conducted on the health information management staff of tertiary care hospitals in Tehran, Iran. A total of 155 participants were randomly selected from 400 staff. Data were collected by two standard questionnaires. The SE and OC was measured using Eysenck SE scale and Meyer and Allen's three component model, respectively. The collected data were analyzed with the SPSS (version 16) using statistical tests of of independent T-test, Pearson Correlation coefficient, one way ANOVA and F tests. The OC and SE of the employees' were 67.8?, out of 120 (weak) and 21.0 out of 30 (moderate), respectively. The values for affective commitment, normative commitment, and continuance commitment were respectively 21.3 out of 40 (moderate), 23.9 out of 40 (moderate), and 22.7 out of 40 (moderate). The Pearson correlation coefficient test showed a significant OC and SE was statistically significant (P<0.05). The one way ANOVA test (P<0.05) did not show any significant difference between educational degree and work experience with SE and OC. This research showed that SE and OC ?are moderate. SE and OC have strong correlation with turnover, critical thinking, job satisfaction, and individual and organizational improvement. Therefore, applying appropriate human resource policies is crucial to reinforce these measures.

  8. An analysis of the content of food industry pledges on marketing to children.

    PubMed

    Hawkes, Corinna; Harris, Jennifer L

    2011-08-01

    To identify pledges made by the food industry to change food marketing to children worldwide, examine their content and discuss their potential to reduce the harmful effects of food marketing to children. A search for pledges and specific commitments made by participating companies and a content analysis of their scope and criteria used to define the marketing covered or excluded. Global. Food industry pledges. Between 2005 and 2009, the food industry developed thirteen pledges on food marketing to children, involving fifty-two food companies. Two of the pledges were global, two were regional and nine applied to specific countries. Three were specific to the soft drinks industry and to the fast-food industry, with the rest being food industry wide. Ten of the pledges required companies to publish individual commitments; a total of eighty-two such commitments were published, many of which extended beyond the minimum standards set in the pledges. All pledges included definitions of children and child-targeted media, as well as the communication channels and marketing techniques covered, and permitted companies to set criteria for foods that are exempted from any restrictions. There were many similarities between the pledges and individual commitments; however, there were also many differences. The development of pledges on food marketing to children in such a short span of time is impressive. However, limitations and inconsistencies in the pledges and commitments suggest that the food industry has a long way to go if its pledges are to comprehensively reduce the exposure and power of marketing to children.

  9. Characterization of Radiation Hardened Bipolar Linear Devices for High Total Dose Missions

    NASA Technical Reports Server (NTRS)

    McClure, Steven S.; Harris, Richard D.; Rax, Bernard G.; Thorbourn, Dennis O.

    2012-01-01

    Radiation hardened linear devices are characterized for performance in combined total dose and displacement damage environments for a mission scenario with a high radiation level. Performance at low and high dose rate for both biased and unbiased conditions is compared and the impact to hardness assurance methodology is discussed.

  10. Tumor Induction in Mice After Localized Single- or Fractionated-Dose Irradiation: Differences in Tumor Histotype and Genetic Susceptibility Based on Dose Scheduling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edmondson, Elijah F., E-mail: elijah.edmondson@colostate.edu; Hunter, Nancy R.; Weil, Michael M.

    2015-07-15

    Purpose: To investigate differences in tumor histotype, incidence, latency, and strain susceptibility in mice exposed to single-dose or clinically relevant, fractioned-dose γ-ray radiation. Methods and Materials: C3Hf/Kam and C57BL/6J mice were locally irradiated to the right hindlimb with either single large doses between 10 and 70 Gy or fractionated doses totaling 40 to 80 Gy delivered at 2-Gy/d fractions, 5 d/wk, for 4 to 8 weeks. The mice were closely evaluated for tumor development in the irradiated field for 800 days after irradiation, and all tumors were characterized histologically. Results: A total of 210 tumors were induced within the radiation field in 788 mice. Anmore » overall decrease in tumor incidence was observed after fractionated irradiation (16.4%) in comparison with single-dose irradiation (36.1%). Sarcomas were the predominant postirradiation tumor observed (n=201), with carcinomas occurring less frequently (n=9). The proportion of mice developing tumors increased significantly with total dose for both single-dose and fractionated schedules, and latencies were significantly decreased in mice exposed to larger total doses. C3Hf/Kam mice were more susceptible to tumor induction than C57BL/6J mice after single-dose irradiation; however, significant differences in tumor susceptibilities after fractionated radiation were not observed. For both strains of mice, osteosarcomas and hemangiosarcomas were significantly more common after fractionated irradiation, whereas fibrosarcomas and malignant fibrous histiocytomas were significantly more common after single-dose irradiation. Conclusions: This study investigated the tumorigenic effect of acute large doses in comparison with fractionated radiation in which both the dose and delivery schedule were similar to those used in clinical radiation therapy. Differences in tumor histotype after single-dose or fractionated radiation exposures provide novel in vivo evidence for differences in tumor susceptibility among stromal cell populations.« less

  11. SU-E-T-540: Volumetric Modulated Total Body Irradiation Using a Rotational Lazy Susan-Like Immobilization System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gu, X; Hrycushko, B; Lee, H

    2014-06-01

    Purpose: Traditional extended SSD total body irradiation (TBI) techniques can be problematic in terms of patient comfort and/or dose uniformity. This work aims to develop a comfortable TBI technique that achieves a uniform dose distribution to the total body while reducing the dose to organs at risk for complications. Methods: To maximize patient comfort, a lazy Susan-like couch top immobilization system which rotates about a pivot point was developed. During CT simulation, a patient is immobilized by a Vac-Lok bag within the body frame. The patient is scanned head-first and then feet-first following 180° rotation of the frame. The twomore » scans are imported into the Pinnacle treatment planning system and concatenated to give a full-body CT dataset. Treatment planning matches multiple isocenter volumetric modulated arc (VMAT) fields of the upper body and multiple isocenter parallel-opposed fields of the lower body. VMAT fields of the torso are optimized to satisfy lung dose constraints while achieving a therapeutic dose to the torso. The multiple isocenter VMAT fields are delivered with an indexed couch, followed by body frame rotation about the pivot point to treat the lower body isocenters. The treatment workflow was simulated with a Rando phantom, and the plan was mapped to a solid water slab phantom for point- and film-dose measurements at multiple locations. Results: The treatment plan of 12Gy over 8 fractions achieved 80.2% coverage of the total body volume within ±10% of the prescription dose. The mean lung dose was 8.1 Gy. All ion chamber measurements were within ±1.7% compared to the calculated point doses. All relative film dosimetry showed at least a 98.0% gamma passing rate using a 3mm/3% passing criteria. Conclusion: The proposed patient comfort-oriented TBI technique provides for a uniform dose distribution within the total body while reducing the dose to the lungs.« less

  12. Low-dose CT for quantitative analysis in acute respiratory distress syndrome

    DTIC Science & Technology

    2013-08-31

    noise of scans performed at 140, 60, 15 and 7.5 mAs corresponded to 10, 16, 38 and 74 Hounsfield Units , respectively. Conclusions: A reduction of...slice of a series, total lung volume, total lung tissue mass and frequency distribution of lung CT numbers expressed in Hounsfield Units (HU) were...tomography; HU: Hounsfield units ; CTDIvol: volumetric computed tomography dose index; DLP: dose length product; E: effective dose; SD: standard deviation

  13. LM193 Dual Differential Comparator Total Ionizing Dose Test Report

    NASA Technical Reports Server (NTRS)

    Topper, Alyson; Forney, James; Campola, Michael

    2017-01-01

    The purpose of this test was to characterize the flight lot of Texas Instruments' LM193 (flight part number is 5962-9452601Q2A) for total dose response. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) was determined.

  14. Dose-Dependent Model of Caffeine Effects on Human Vigilance during Total Sleep Deprivation

    DTIC Science & Technology

    2014-05-20

    does not consider the absorption of caffeine . This is a reasonable approximation for caffeine when ingested via coffee , tea, energy drinks, and most...Dose-dependent model of caffeine effects on human vigilance during total sleep deprivation Sridhar Ramakrishnan a, Srinivas Laxminarayan a, Nancy J...We modeled the dose-dependent effects of caffeine on human vigilance. The model predicted the effects of both single and repeated caffeine doses

  15. Meeting The Joint Commission's Dose Incident Identification and External Benchmarking Requirements Using the ACR's Dose Index Registry.

    PubMed

    Bohl, Michael A; Goswami, Roopa; Strassner, Brett; Stanger, Paula

    2016-08-01

    The purpose of this investigation was to evaluate the potential of using the ACR's Dose Index Registry(®) to meet The Joint Commission's requirements to identify incidents in which the radiation dose index from diagnostic CT examinations exceeded the protocol's expected dose index range. In total, 10,970 records in the Dose Index Registry were statistically analyzed to establish both an upper and lower expected dose index for each protocol. All 2015 studies to date were then retrospectively reviewed to identify examinations whose total examination dose index exceeded the protocol's defined upper threshold. Each dose incident was then logged and reviewed per the new Joint Commission requirements. Facilities may leverage their participation in the ACR's Dose Index Registry to fully meet The Joint Commission's dose incident identification review and external benchmarking requirements. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  16. The effects of hot carrier and swift heavy ion irradiation on electrical characteristics of advanced 200 GHz SiGe HBTs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vinayakprasanna, N. H.; Praveen, K. C.; Prakash, A. P. Gnana, E-mail: gnanaprakash@physics.uni-mysore.ac.in

    The 200 GHz SiGe HBTs were irradiated with 80 MeV Carbon ions up to a total dose of 100 Mrad to understand the degradation in electrical characteristics. The degradation in the electrical characteristics of SiGe HBTs was also studied by mixed mode electrical stress up to 10,000 s. The electrical characteristics were measured before and after every total dose and after fixed stress time. The normalized peak h{sub FE} of the stressed and irradiated SiGe HBTs are compared to estimate the equivalent stress time for a particular total dose. These correlations are drawn for the first time and the resultsmore » will establish a systematic relation between stress time and total dose.« less

  17. On the sensitivity of TG-119 and IROC credentialing to TPS commissioning errors.

    PubMed

    McVicker, Drew; Yin, Fang-Fang; Adamson, Justus D

    2016-01-08

    We investigate the sensitivity of IMRT commissioning using the TG-119 C-shape phantom and credentialing with the IROC head and neck phantom to treatment planning system commissioning errors. We introduced errors into the various aspects of the commissioning process for a 6X photon energy modeled using the analytical anisotropic algorithm within a commercial treatment planning system. Errors were implemented into the various components of the dose calculation algorithm including primary photons, secondary photons, electron contamination, and MLC parameters. For each error we evaluated the probability that it could be committed unknowingly during the dose algorithm commissioning stage, and the probability of it being identified during the verification stage. The clinical impact of each commissioning error was evaluated using representative IMRT plans including low and intermediate risk prostate, head and neck, mesothelioma, and scalp; the sensitivity of the TG-119 and IROC phantoms was evaluated by comparing dosimetric changes to the dose planes where film measurements occur and change in point doses where dosimeter measurements occur. No commissioning errors were found to have both a low probability of detection and high clinical severity. When errors do occur, the IROC credentialing and TG 119 commissioning criteria are generally effective at detecting them; however, for the IROC phantom, OAR point-dose measurements are the most sensitive despite being currently excluded from IROC analysis. Point-dose measurements with an absolute dose constraint were the most effective at detecting errors, while film analysis using a gamma comparison and the IROC film distance to agreement criteria were less effective at detecting the specific commissioning errors implemented here.

  18. The Use of Match Statistics that Discriminate Between Successful and Unsuccessful Soccer Teams

    PubMed Central

    Castellano, Julen; Casamichana, David; Lago, Carlos

    2012-01-01

    Three soccer World Cups were analysed with the aim of identifying the match statistics which best discriminated between winning, drawing and losing teams. The analysis was based on 177 matches played during the three most recent World Cup tournaments: Korea/Japan 2002 (59), Germany 2006 (59) and South Africa 2010 (59). Two categories of variables were studied: 1) those related to attacking play: goals scored, total shots, shots on target, shots off target, ball possession, number of off-sides committed, fouls received and corners; and 2) those related to defence: total shots received, shots on target received, shots off target received, off-sides received, fouls committed, corners against, yellow cards and red cards. Discriminant analysis of these matches revealed the following: (a) the variables related to attacking play that best differentiated between winning, drawing and losing teams were total shots, shots on target and ball possession; and (b) the most discriminating variables related to defence were total shots received and shots on target received. These results suggest that winning, drawing and losing national teams may be discriminated from one another on the basis of variables such as ball possession and the effectiveness of their attacking play. This information may be of benefit to both coaches and players, adding to their knowledge about soccer performance indicators and helping to guide the training process. PMID:23487020

  19. Dosimetric Evaluation Between Megavoltage Cone-Beam Computed Tomography and Body Mass Index for Intracranial, Thoracic, and Pelvic Localization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    VanAntwerp, April E.; Raymond, Sarah M., E-mail: raymons9@ccf.org; Addington, Mark C.

    2011-10-01

    The aim of this study was to evaluate radiation dose for organs at risk (OAR) within the cranium, thorax, and pelvis from megavoltage cone-beam computed tomography (MV-CBCT). Using a clinical treatment planning system, CBCT doses were calculated from 60 patient datasets using 27.4 x 27.4 cm{sup 2} field size and 200{sup o} arc length. The body mass indices (BMIs) for these patients range from 17.2-48.4 kg/m{sup 2}. A total of 60 CBCT plans were created and calculated with heterogeneity corrections, with monitor units (MU) that varied from 8, 4, and 2 MU per plan. The isocenters of these plans weremore » placed at defined anatomical structures. The maximum dose, dose to the isocenter, and mean dose to the selected critical organs were analyzed. The study found that maximum and isocenter doses were weakly associated with BMI, but linearly associated with the total MU. Average maximum/isocenter doses in the cranium were 10.0 ({+-} 0.18)/7.0 ({+-} 0.08) cGy, 5.0 ({+-} 0.09)/3.5 ({+-} 0.05) cGy, and 2.5 ({+-} .04)/1.8 ({+-} 0.05) cGy for 8, 4, and 2 MU, respectively. Similar trends but slightly larger maximum/isocenter doses were found in the thoracic and pelvic regions. For the cranial region, the average mean doses with a total of 8 MU to the eye, lens, and brain were 9.7 ({+-} 0.12) cGy, 9.1 ({+-} 0.16) cGy, and 7.2 ({+-} 0.10) cGy, respectively. For the thoracic region, the average mean doses to the lung, heart, and spinal cord were 6.6 ({+-} 0.05) cGy, 6.9 ({+-} 1.2) cGy, and 4.7 ({+-} 0.8) cGy, respectively. For the pelvic region, the average mean dose to the femoral heads was 6.4 ({+-} 1.1) cGy. The MV-CBCT doses were linearly associated with the total MU but weakly dependent on patients' BMIs. Daily MV-CBCT has a cumulative effect on the total body dose and critical organs, which should be carefully considered for clinical impacts.« less

  20. Effect of γ-dose rate and total dose interrelation on the polymeric hydrogel: A novel injectable male contraceptive

    NASA Astrophysics Data System (ADS)

    Jha, Pradeep K.; Jha, Rakhi; Gupta, B. L.; Guha, Sujoy K.

    2010-05-01

    Functional necessity to use a particular range of dose rate and total dose of γ-initiated polymerization to manufacture a novel polymeric hydrogel RISUG ® (reversible inhibition of sperm under guidance) made of styrene maleic anhydride (SMA) dissolved in dimethyl sulphoxide (DMSO), for its broad biomedical application explores new dimension of research. The present work involves 16 irradiated samples. They were tested by fourier transform infrared spectroscopy, matrix assisted laser desorption/ionization-TOF, field emission scanning electron microscopy, high resolution transmission electron microscopy, etc. to see the interrelation effect of gamma dose rates (8.25, 17.29, 20.01 and 25.00 Gy/min) and four sets of doses (1.8, 2.0, 2.2 and 2.4 kGy) on the molecular weight, molecular weight distribution and porosity analysis of the biopolymeric drug RISUG ®. The results of randomized experiment indicated that a range of 18-24 Gy/min γ-dose rate and 2.0-2.4 kGy γ-total doses is suitable for the desirable in vivo performance of the contraceptive copolymer.

  1. [Forensic importance of homicide].

    PubMed

    Novaković, Milan

    2009-01-01

    This study encompassed the total number of homicides in Bosnia and Herzegovina (B&H) in the period from 1st January 1997 to 31st December 2006 and then analysed homicidal behaviour. The aim is to assess the differences between the people who committed violent and those who committed accidental homicide in Bosnia and Herzegovina. In a multicentric, retrospective study of comparing the groups with equal number of respondents we analysed the individuals who had committed violent (n=135) and accidental homicides (n=135). The homicides were tested by using sociodemographic and psychosocial items. Measurement instruments were: General data list, Eysenck Personality Questionnaire (EPQ), Hamilton Depression Rating Scale (HDRS), Emotions Profile Index (EPI). The descriptive and multivariable logistic analysis was done statistically. In the descriptive analysis the socio-demographically violent murderers were: male gender (chi 2=3.340, P=0.009), more workers than officials (chi 2=7.340, P=0.011), fathers were more often workers/farmers (chi 2=1.430, P=0.046), gambling (chi 2=13.100, P=0.001) and possible recidivism (chi 2=6.770, a P=0.001). The accidental murderers were family people (chi 2=4.100, P=0.041), with more frequent drug abuse (chi 2=3.190, P=0.012) and they would not repeat the delict. In the multivariate analysis the violent murderers were highly discriminated (P=0.001) from accidental ones by: war involvement r=0.1148, OR=2.971 (95%), CI=1.040-7.890; age, father's education, psychoticism (EPQ) r =-0.1085, OR=0.291 (95%), CI=0.110-0870, HDRS-total r=-0.1797, OR=0.830 (95%), CI=0.710-0.930, destructiveness r=0.1270, OR=1.560 (95%), (CI=1.197-2.032, and deprivation in the P. I. E. tests. By the violence of their acts murderers confirm micro-social model of transferring the violence, and transition and heredity confirm the ecological-developmental trans-generation model of violence. Accidental murderers commit homicide in anomy, with intoxications and prolonged psycho-traumatism.

  2. Flavonoids and Tannins from Smilax china L. Rhizome Induce Apoptosis Via Mitochondrial Pathway and MDM2-p53 Signaling in Human Lung Adenocarcinoma Cells.

    PubMed

    Fu, San; Yang, Yanfang; Liu, Dan; Luo, Yan; Ye, Xiaochuan; Liu, Yanwen; Chen, Xin; Wang, Song; Wu, Hezhen; Wang, Yuhang; Hu, Qiwei; You, Pengtao

    2017-01-01

    In vitro evidence indicates that Smilax china L. rhizome (SCR) can inhibit cell proliferation. Therefore, in the present study, we analyzed the effects in vitro of SCR extracts on human lung adenocarcinoma A549 cells. Our results showed that A549 cell growth was inhibited in a dose- and time-dependent manner after treatment with SCR extracts. Total flavonoids and total tannins from SCR induced A549 apoptosis in a dose-dependent manner, as shown by our flow cytometry analysis, which was consistent with the alterations in nuclear morphology we observed. In addition, the total apoptotic rate induced by total tannins was higher than the rate induced by total flavonoids at the same dose. Cleaved-caspase-3 protein levels in A549 cells after treatment with total flavonoids or total tannins were increased in a dose-dependent manner, followed by the activation of caspase-8 and caspase-9, finally triggering to PARP cleavage. Furthermore, total flavonoids and total tannins increased the expression of Bax, decreased the expression of Bcl-2, and promoted cytochrome [Formula: see text] release. Moreover, MDM2 and p-MDM2 proteins were decreased, while p53 and p-p53 proteins were increased, both in a dose-dependent manner, after A549 treatment with total flavonoids and total tannins. Finally, cleaved-caspase-3 protein levels in the total flavonoids or total tannins-treated H1299 (p53 null) and p53-knockdown A549 cells were increased. Our results indicated that total flavonoids and total tannins from SCR exerted a remarkable effect in reducing A549 growth through their action on mitochondrial pathway and disruption of MDM2-p53 balance. Hence, our findings demonstrated a potential application of total flavonoids and total tannins from SCR in the treatment of human lung adenocarcinoma.

  3. Does TQM Affect Teaching and Learning?

    ERIC Educational Resources Information Center

    Mauriel, John J.; And Others

    Many schools and school districts are attempting to introduce principles and practices of Total Quality Management (TQM). These attempts take many forms with varying degrees of commitment of resources and management attention. This paper describes the research design of a study intended to identify best current practices in applying TQM concepts…

  4. Phoenix: Quantum Quality at Maricopa: TQM on Campus, Case Study Number Two.

    ERIC Educational Resources Information Center

    Assar, Kathleen E.

    1993-01-01

    Implementation of the Total Quality Management approach in the Maricopa County Community College District (Arizona), a large 10-campus system, is described. The program's current early stages are reported noting the serious administrative commitment and thorough training, seen as key factors in potential success. (MSE)

  5. The Role of Individual Differences in Employee Adoption of TQM Orientation.

    ERIC Educational Resources Information Center

    Coyle-Shapiro, Jacqueline A. -M.; Morrow, Paula C.

    2003-01-01

    Employee surveys before and 9 and 32 months after total quality management (TQM) implementation (n=186, 166, 118) identified three individual characteristics that collectively explained the variance in and better predicted TQM adoption: organizational commitment, trust in colleagues, and importance of higher-order needs for achievement and…

  6. 10 Paths to Green

    ERIC Educational Resources Information Center

    Kennedy, Mike

    2008-01-01

    Some institutions may feel comfortable with a few baby steps into the green world, while others may be ready to commit totally to environmental consciousness. Here, the author discusses 10 areas in which educators and administrators can beef up their green portfolio. These areas are in: alternative fuel, bikes/walking, water, education tools,…

  7. Identity Development in German Adolescents with and without Visual Impairments

    ERIC Educational Resources Information Center

    Pinquart, Martin; Pfeiffer, Jens P.

    2013-01-01

    Introduction: The study reported here assessed the exploration of identity and commitment to an identity in German adolescents with and without visual impairments. Methods: In total, 178 adolescents with visual impairments (blindness or low vision) and 526 sighted adolescents completed the Ego Identity Process Questionnaire. Results: The levels of…

  8. Risk Management and Crisis Response: Are You Prepared?

    ERIC Educational Resources Information Center

    Schirick, Ed

    2002-01-01

    How a camp responds to a crisis may determine whether it can survive financially. Effective risk management requires total commitment from ownership and management, and staff involvement. Steps in formulating a risk management plan include identifying all potential crises and their frequency and severity potential, developing responses,…

  9. Total Access: Making College Web Sites Accessible to Students with Disabilities

    ERIC Educational Resources Information Center

    Bruyere, Susanne

    2008-01-01

    Colleges increasingly rely on the Web to attract, inform, and interact with students. This makes Web site accessibility and usability critical concerns, particularly for public community colleges, which educate sizable numbers of students with disabilities. As committed providers of postsecondary education to students with disabilities and thus a…

  10. Implementing the Multicultural Education Perspective into the Nursing Curriculum.

    ERIC Educational Resources Information Center

    White, Hazel L.

    This paper was written to provide nurse educators with strategies for implementing multicultural concepts into their nursing programs. Administrators are urged to design their total educational process and educational content to reflect a commitment to cultural pluralism, in which traits of nonmainstream cultures are treated as differences rather…

  11. 12 CFR 1291.5 - Competitive application program.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... (excluding the value of sweat equity), provided that the project's uses of funds also include or exclude... project. Cash costs do not include in-kind donations, voluntary professional labor or services, or sweat... services (excluding the value of sweat equity) committed to the project as part of the total development...

  12. 12 CFR 1291.5 - Competitive application program.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... (excluding the value of sweat equity), provided that the project's uses of funds also include or exclude... project. Cash costs do not include in-kind donations, voluntary professional labor or services, or sweat... services (excluding the value of sweat equity) committed to the project as part of the total development...

  13. 12 CFR 1291.5 - Competitive application program.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... (excluding the value of sweat equity), provided that the project's uses of funds also include or exclude... project. Cash costs do not include in-kind donations, voluntary professional labor or services, or sweat... services (excluding the value of sweat equity) committed to the project as part of the total development...

  14. 12 CFR 1291.5 - Competitive application program.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... (excluding the value of sweat equity), provided that the project's uses of funds also include or exclude... project. Cash costs do not include in-kind donations, voluntary professional labor or services, or sweat... services (excluding the value of sweat equity) committed to the project as part of the total development...

  15. TQM--Will It Work in Your Library?

    ERIC Educational Resources Information Center

    Butcher, Karyle

    Scarce resources, changing customer expectation, and the changing role of top management are all factors that have contributed to the implementation of total quality management (TQM) in libraries. Instructional articles, conferences, and videos can alleviate some concerns of cost and time commitment. Many libraries already practice some of the…

  16. Writing for Learning: How to Achieve a Total College Commitment.

    ERIC Educational Resources Information Center

    Adams, Barbara; And Others

    Various aspects of the writing across the curriculum program at Somerset County College (SCC) are discussed in these four presentations. Introductory comments by Myrna Smith trace the development of the writing across the curriculum program at SCC. Angela Bodino's presentation, "Writing as Learning Across the Curriculum", explores the…

  17. Student public commitment in a school-based diabetes prevention project: impact on physical health and health behavior.

    PubMed

    DeBar, Lynn L; Schneider, Margaret; Drews, Kimberly L; Ford, Eileen G; Stadler, Diane D; Moe, Esther L; White, Mamie; Hernandez, Arthur E; Solomon, Sara; Jessup, Ann; Venditti, Elizabeth M

    2011-09-20

    As concern about youth obesity continues to mount, there is increasing consideration of widespread policy changes to support improved nutritional and enhanced physical activity offerings in schools. A critical element in the success of such programs may be to involve students as spokespeople for the program. Making such a public commitment to healthy lifestyle program targets (improved nutrition and enhanced physical activity) may potentiate healthy behavior changes among such students and provide a model for their peers. This paper examines whether student's "public commitment"--voluntary participation as a peer communicator or in student-generated media opportunities--in a school-based intervention to prevent diabetes and reduce obesity predicted improved study outcomes including reduced obesity and improved health behaviors. Secondary analysis of data from a 3-year randomized controlled trial conducted in 42 middle schools examining the impact of a multi-component school-based program on body mass index (BMI) and student health behaviors. A total of 4603 students were assessed at the beginning of sixth grade and the end of eighth grade. Process evaluation data were collected throughout the course of the intervention. All analyses were adjusted for students' baseline values. For this paper, the students in the schools randomized to receive the intervention were further divided into two groups: those who participated in public commitment activities and those who did not. Students from comparable schools randomized to the assessment condition constituted the control group. We found a lower percentage of obesity (greater than or equal to the 95th percentile for BMI) at the end of the study among the group participating in public commitment activities compared to the control group (21.5% vs. 26.6%, p = 0.02). The difference in obesity rates at the end of the study was even greater among the subgroup of students who were overweight or obese at baseline; 44.6% for the "public commitment" group, versus 53.2% for the control group (p = 0.01). There was no difference in obesity rates between the group not participating in public commitment activities and the control group (26.4% vs. 26.6%). Participating in public commitment activities during the HEALTHY study may have potentiated the changes promoted by the behavioral, nutrition, and physical activity intervention components. ClinicalTrials.gov number, NCT00458029.

  18. Student public commitment in a school-based diabetes prevention project: impact on physical health and health behavior

    PubMed Central

    2011-01-01

    Background As concern about youth obesity continues to mount, there is increasing consideration of widespread policy changes to support improved nutritional and enhanced physical activity offerings in schools. A critical element in the success of such programs may be to involve students as spokespeople for the program. Making such a public commitment to healthy lifestyle program targets (improved nutrition and enhanced physical activity) may potentiate healthy behavior changes among such students and provide a model for their peers. This paper examines whether student's "public commitment"--voluntary participation as a peer communicator or in student-generated media opportunities--in a school-based intervention to prevent diabetes and reduce obesity predicted improved study outcomes including reduced obesity and improved health behaviors. Methods Secondary analysis of data from a 3-year randomized controlled trial conducted in 42 middle schools examining the impact of a multi-component school-based program on body mass index (BMI) and student health behaviors. A total of 4603 students were assessed at the beginning of sixth grade and the end of eighth grade. Process evaluation data were collected throughout the course of the intervention. All analyses were adjusted for students' baseline values. For this paper, the students in the schools randomized to receive the intervention were further divided into two groups: those who participated in public commitment activities and those who did not. Students from comparable schools randomized to the assessment condition constituted the control group. Results We found a lower percentage of obesity (greater than or equal to the 95th percentile for BMI) at the end of the study among the group participating in public commitment activities compared to the control group (21.5% vs. 26.6%, p = 0.02). The difference in obesity rates at the end of the study was even greater among the subgroup of students who were overweight or obese at baseline; 44.6% for the "public commitment" group, versus 53.2% for the control group (p = 0.01). There was no difference in obesity rates between the group not participating in public commitment activities and the control group (26.4% vs. 26.6%). Conclusions Participating in public commitment activities during the HEALTHY study may have potentiated the changes promoted by the behavioral, nutrition, and physical activity intervention components. Trial Registration ClinicalTrials.gov number, NCT00458029 PMID:21933431

  19. Long-term erythemal UV doses at Sodankylä estimated using total ozone, sunshine duration, and snow depth

    NASA Astrophysics Data System (ADS)

    Lindfors, A. V.; Arola, A.; Kaurola, J.; Taalas, P.; SvenøE, T.

    2003-08-01

    A method for estimating daily erythemal UV doses using total ozone, sunshine duration, and snow depth has been developed. The method consists of three steps: (1) daily clear-sky UV doses were simulated using the UVSPEC radiative transfer program, with daily values of total ozone as input data, (2) an empirical relationship was sought between the simulated clear-sky UV doses, the measured UV doses, and the duration of bright sunshine, and (3) daily erythemal UV doses were estimated using this relationship. The method accounts for the varying surface albedo by dividing the period of interest into winter and summer days, depending on the snow depth. Using this method, the daily erythemal UV doses at Sodankylä were estimated for the period 1950-1999. This was done using Tromsø's total ozone together with Sodankylä's own sunshine duration and snow depth as input data. Although the method is fairly simple, the results are in good agreement, even on the daily scale, with the UV radiation measured with the Brewer spectrophotometer at Sodankylä. Over the period 1950-1999 a statistically significant increasing trend of 3.9% per decade in erythemal UV doses was found for March. The fact that this trend is much more pronounced during the latter part of the period, which is also the case for April, suggests a connection to the stratospheric ozone depletion. For July, on the other hand, a significant decreasing trend of 3.3% per decade, supported by the changes in both total ozone and sunshine duration, was found.

  20. Safety of an ED High-Dose Opioid Protocol for Sickle Cell Disease Pain.

    PubMed

    Tanabe, Paula; Martinovich, Zoran; Buckley, Barbara; Schmelzer, Annie; Paice, Judith A

    2015-05-01

    A nurse-initiated high dose, opioid protocol for vaso-occlusive crisis (VOC) was implemented. Total intravenous morphine sulfate equivalents (IVMSE) in mgs] and safety was evaluated. A medical record review was conducted for all ED visits in adult patients with VOC post protocol implementation. Opioids doses and routes administered during the ED stay, and six hours into the hospital admission were abstracted and total IVMSE administered calculated. Oxygen saturation (SPO2), respiratory rate (RR), administration of naloxone or vasoactive medications, evidence of respiratory arrest, or any other types of resuscitation effort were abstracted. A RR of <10 or SPO2 <92% were coded as abnormal. Descriptive statistics report the total dose. Logistic regression was used to predict abnormal events. Predictors were age, gender, ED dose (10 mg increments) administered, and time from 1st dose to discharge from ED. 72 patients, 603 visits, 276 admitted. The total (ED & hospital dose) mean (95% CI) mg IVMSE administered for all visits was 93 mg (CI 86, 100), ED visit 63 mg (CI 59, 67) and hospital 66 mg (CI 59, 72). The mean (SD) time from administration of 1st analgesic dose to discharge from the ED was 203 (143) minutes, (range = 30-1396 minutes). During two visits, patients experienced a RR <10; while 61 visits were associated with a SPO2 <92%. No medications were administered, or resuscitative measures required. Controlling for demographics and evaluated at the average total ED dose, the longer patients were in the ED, patients were 1.359 times more likely to experience an abnormal vital sign. Controlling for demographics and evaluated at the average total time in the ED, for every 10 mg increase in IVMSE, patients were 1.057 times more likely to experience an abnormal vital sign. The effect of ED dose on the odds of experiencing an abnormal vital sign decreased by a multiplicative factor of 0.0970 for every 1 hour increase in time until discharge. The larger the dose administered in less time, the more likely patients experienced an abnormal vital sign. High opioid doses were safely administered to patients with sickle cell disease. Copyright © 2015 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved.

  1. Environmental health and safety issues related to the use of low-level radioactive waste (LLRW) at hospitals and medical research institutions and compliance determination with the Clean Air Act standards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kasinathan, R.; Kanchan, A.

    1995-12-31

    Currently, the United States Nuclear Regulatory Commission (NRC) has standards for procedures, performance activities and technical specifications on storage of Low-Level Radioactive Waste (LLRW) under 10 CFR Part 20. The United States Environmental Protection Agency (EPA) is proposing environmental standards for the management, storage and disposal of LLRW. The proposed standards, which will become 40 CFR part 193 when finalized, limits the committed effective dose to members of the public from the management and storage of LLRW, committed effective doses resulting from LLRW disposal and levels of radiological contamination of underground sources of drinking water as a result of themore » activities subject to management, storage and disposal of LLRW. Further, under Title III of the Clean Air Act Amendments, radionuclides are required to be inventoried for all generators. For hospitals and medical research institutions, quantities of LLRW are often below the concentrations required under reporting and record keeping requirements of 10 CFR 20. However, in many instances, the facility may require NRC permits and compliance with air quality dispersion modeling requirements. This paper presents the typical radionuclides used in hospitals and medical research institutions, and strategies to evaluate their usage and steps to achieve compliance. Air quality dispersion modeling by use of the COMPLY model is demonstrated to evaluate the fate of radionuclides released from on-site incineration of LLRW. The paper concludes that no significant threat is posed from the incineration of LLRW.« less

  2. Oral Tranexamic Acid Reduces Transfusions in Total Knee Arthroplasty.

    PubMed

    Perreault, Roger E; Fournier, Christine A; Mattingly, David A; Junghans, Richard P; Talmo, Carl T

    2017-10-01

    Tranexamic acid (TXA) reduces intraoperative blood loss and transfusions in patients undergoing total knee arthroplasty. Although numerous studies demonstrate the efficacy of intravenous and topical TXA in these patients, few demonstrate the effectiveness and appropriate dosing recommendations of oral formulations. A retrospective cohort study was performed to evaluate differences in transfusion requirements in patients undergoing primary unilateral total knee arthroplasty with either no TXA (n = 866), a single-dose of oral TXA (n = 157), or both preoperative and postoperative oral TXA (n = 1049). Secondary outcomes included postoperative hemoglobin drop, total units transfused, length of stay, drain output, and cell salvage volume. Transfusion rates decreased from 15.4% in the no-oral tranexamic acid (OTA) group to 9.6% in the single-dose OTA group (P < .001) and 7% in the 2-dose group (P < .001), with no difference in transfusion rates between the single- and 2-dose groups (P = .390). In addition, postoperative hemoglobin drop was reduced from 4.2 g/dL in the no-OTA group to 3.5 g/dL in the single-dose group (P < .01) and to 3.4 g/dL in the 2-dose group (P < .01), without a difference between the single- and 2-dose groups (P = .233). OTA reduces transfusions, with greater ease of administration and improved cost-effectiveness relative to other forms of delivery. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. A Comprehensive Quality Assurance Program for Personnel and Procedures in Radiation Oncology: Value of Voluntary Error Reporting and Checklists

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalapurakal, John A., E-mail: j-kalapurakal@northwestern.edu; Zafirovski, Aleksandar; Smith, Jeffery

    Purpose: This report describes the value of a voluntary error reporting system and the impact of a series of quality assurance (QA) measures including checklists and timeouts on reported error rates in patients receiving radiation therapy. Methods and Materials: A voluntary error reporting system was instituted with the goal of recording errors, analyzing their clinical impact, and guiding the implementation of targeted QA measures. In response to errors committed in relation to treatment of the wrong patient, wrong treatment site, and wrong dose, a novel initiative involving the use of checklists and timeouts for all staff was implemented. The impactmore » of these and other QA initiatives was analyzed. Results: From 2001 to 2011, a total of 256 errors in 139 patients after 284,810 external radiation treatments (0.09% per treatment) were recorded in our voluntary error database. The incidence of errors related to patient/tumor site, treatment planning/data transfer, and patient setup/treatment delivery was 9%, 40.2%, and 50.8%, respectively. The compliance rate for the checklists and timeouts initiative was 97% (P<.001). These and other QA measures resulted in a significant reduction in many categories of errors. The introduction of checklists and timeouts has been successful in eliminating errors related to wrong patient, wrong site, and wrong dose. Conclusions: A comprehensive QA program that regularly monitors staff compliance together with a robust voluntary error reporting system can reduce or eliminate errors that could result in serious patient injury. We recommend the adoption of these relatively simple QA initiatives including the use of checklists and timeouts for all staff to improve the safety of patients undergoing radiation therapy in the modern era.« less

  4. High dose psilocybin is associated with positive subjective effects in healthy volunteers.

    PubMed

    Nicholas, Christopher R; Henriquez, Kelsey M; Gassman, Michele C; Cooper, Karen M; Muller, Daniel; Hetzel, Scott; Brown, Randall T; Cozzi, Nicholas V; Thomas, Chantelle; Hutson, Paul R

    2018-06-01

    The aim of the current study was to investigate the relationship between escalating higher doses of psilocybin and the potential psilocybin occasioned positive subjective effects. Healthy participants ( n=12) were given three escalating doses of oral psilocybin (0.3 mg/kg; 0.45 mg/kg; 0.6 mg/kg) or (18.8-36.6 mg; 27.1-54.0 mg; 36.3-59.2 mg) a minimum of four weeks apart in a supervised setting. Blood and urine samples, vital signs, and electrocardiograms were obtained. Subjective effects were assessed using the Mystical Experience Questionnaire and Persisting Effects Questionnaire. There was a significant linear dose-related response in Mystical Experience Questionnaire total score and the transcendence of time and space subscale, but not in the rate of a complete mystical experience. There was also a significant difference between dose 3 compared to dose 1 on the transcendence of time and space subscale, while no dose-related differences were found for Mystical Experience Questionnaire total scores or rate of a mystical experience. Persisting Effects Questionnaire positive composite scores 30 days after completion of the last dose were significantly higher than negative composite scores. Persisting Effects Questionnaire results revealed a moderate increase in sense of well-being or life satisfaction on average that was associated with the maximum Mystical Experience Questionnaire total score. Pharmacokinetic measures were associated with dose but not with Mystical Experience Questionnaire total scores or rate of a mystical experience. High doses of psilocybin elicited subjective effects at least as strong as the lower doses and resulted in positive persisting subjective effects 30 days after, indicating that a complete mystical experience was not a prerequisite for positive outcomes.

  5. The impact of ethical climate types on nurses' behaviors in Bosnia and Herzegovina.

    PubMed

    Dinc, M Sait; Huric, Alma

    2017-12-01

    The performance of nurses has become vital in hospitals. Some studies have suggested that nurses' perceptions of the ethical climate in their hospitals are related to higher job satisfaction and organizational commitment and in turn lessen the issue of nursing shortage. (1) The ethical climate types "caring," "independent," "law and code," and "rules" have a significant positive impact on overall job satisfaction. (2) The ethical climate types and overall job satisfaction have significant positive influences on normative and affective and significant negative influences on continuance commitment. The study uses path analysis to understand which types of ethical climate impact overall job satisfaction. It also tries to find the effect of different types of ethical climate and overall job satisfaction on the components of organizational commitment. The relationships between variables were evaluated using factor analysis, reliability, descriptive statistics, correlations, and regression in this study. Participants and research context: A total of 171 useful questionnaires were collected from nurses working in public and private hospitals in Bosnia and Herzegovina. Ethical considerations: Formal research approval was obtained from the administration of each study hospital. Questionnaires with a cover letter were mailed to the hospitals that agreed to participate in the study. In the cover letter, the researchers explained the study purpose, encouraged nurses' voluntary participation, and guaranteed the anonymity of participants. In the first path analyses, "rules" and "caring" climates significantly and positively affected overall job satisfaction. In the second one, while overall job satisfaction and "rules" climate significantly influenced normative commitment, "caring" climate and overall job satisfaction significantly affected affective commitment. The findings of the study have been convenient with the literature. Public and private hospitals can enhance overall job satisfaction and organizational commitment by altering the ethical climate of organizations. Hospital administrations should nurture caring and rule types of ethical climate which influence overall satisfaction. By this way, they could reduce nursing shortage.

  6. Controlled-release systemic delivery - a new concept in cancer chemoprevention

    PubMed Central

    2012-01-01

    Many chemopreventive agents have encountered bioavailability issues in pre-clinical/clinical studies despite high oral doses. We report here a new concept utilizing polycaprolactone implants embedded with test compounds to obtain controlled systemic delivery, circumventing oral bioavailability issues and reducing the total administered dose. Compounds were released from the implants in vitro dose dependently and for long durations (months), which correlated with in vivo release. Polymeric implants of curcumin significantly inhibited tissue DNA adducts following the treatment of rats with benzo[a]pyrene, with the total administered dose being substantially lower than typical oral doses. A comparison of bioavailability of curcumin given by implants showed significantly higher levels of curcumin in the plasma, liver and brain 30 days after treatment compared with the dietary route. Withaferin A implants resulted in a nearly 60% inhibition of lung cancer A549 cell xenografts, but no inhibition occurred when the same total dose was administered intraperitoneally. More than 15 phytochemicals have been tested successfully by this formulation. Together, our data indicate that this novel implant-delivery system circumvents oral bioavailability issues, provides continuous delivery for long durations and lowers the total administered dose, eliciting both chemopreventive/chemotherapeutic activities. This would also allow the assessment of activity of minor constituents and synthetic metabolites, which otherwise remain uninvestigated in vivo. PMID:22696595

  7. Adult cardiac stem cells are multipotent and robustly myogenic: c-kit expression is necessary but not sufficient for their identification.

    PubMed

    Vicinanza, Carla; Aquila, Iolanda; Scalise, Mariangela; Cristiano, Francesca; Marino, Fabiola; Cianflone, Eleonora; Mancuso, Teresa; Marotta, Pina; Sacco, Walter; Lewis, Fiona C; Couch, Liam; Shone, Victoria; Gritti, Giulia; Torella, Annalaura; Smith, Andrew J; Terracciano, Cesare Mn; Britti, Domenico; Veltri, Pierangelo; Indolfi, Ciro; Nadal-Ginard, Bernardo; Ellison-Hughes, Georgina M; Torella, Daniele

    2017-12-01

    Multipotent adult resident cardiac stem cells (CSCs) were first identified by the expression of c-kit, the stem cell factor receptor. However, in the adult myocardium c-kit alone cannot distinguish CSCs from other c-kit-expressing (c-kit pos ) cells. The adult heart indeed contains a heterogeneous mixture of c-kit pos cells, mainly composed of mast and endothelial/progenitor cells. This heterogeneity of cardiac c-kit pos cells has generated confusion and controversy about the existence and role of CSCs in the adult heart. Here, to unravel CSC identity within the heterogeneous c-kit-expressing cardiac cell population, c-kit pos cardiac cells were separated through CD45-positive or -negative sorting followed by c-kit pos sorting. The blood/endothelial lineage-committed (Lineage pos ) CD45 pos c-kit pos cardiac cells were compared to CD45 neg (Lineage neg /Lin neg ) c-kit pos cardiac cells for stemness and myogenic properties in vitro and in vivo. The majority (~90%) of the resident c-kit pos cardiac cells are blood/endothelial lineage-committed CD45 pos CD31 pos c-kit pos cells. In contrast, the Lin neg CD45 neg c-kit pos cardiac cell cohort, which represents ⩽10% of the total c-kit pos cells, contain all the cardiac cells with the properties of adult multipotent CSCs. These characteristics are absent from the c-kit neg and the blood/endothelial lineage-committed c-kit pos cardiac cells. Single Lin neg c-kit pos cell-derived clones, which represent only 1-2% of total c-kit pos myocardial cells, when stimulated with TGF-β/Wnt molecules, acquire full transcriptome and protein expression, sarcomere organisation, spontaneous contraction and electrophysiological properties of differentiated cardiomyocytes (CMs). Genetically tagged cloned progeny of one Lin neg c-kit pos cell when injected into the infarcted myocardium, results in significant regeneration of new CMs, arterioles and capillaries, derived from the injected cells. The CSC's myogenic regenerative capacity is dependent on commitment to the CM lineage through activation of the SMAD2 pathway. Such regeneration was not apparent when blood/endothelial lineage-committed c-kit pos cardiac cells were injected. Thus, among the cardiac c-kit pos cell cohort only a very small fraction has the phenotype and the differentiation/regenerative potential characteristics of true multipotent CSCs.

  8. Collaborative problem solving with a total quality model.

    PubMed

    Volden, C M; Monnig, R

    1993-01-01

    A collaborative problem-solving system committed to the interests of those involved complies with the teachings of the total quality management movement in health care. Deming espoused that any quality system must become an integral part of routine activities. A process that is used consistently in dealing with problems, issues, or conflicts provides a mechanism for accomplishing total quality improvement. The collaborative problem-solving process described here results in quality decision-making. This model incorporates Ishikawa's cause-and-effect (fishbone) diagram, Moore's key causes of conflict, and the steps of the University of North Dakota Conflict Resolution Center's collaborative problem solving model.

  9. Compendium of Total Ionizing Dose and Displacement Damage for Candidate Spacecraft Electronics for NASA

    NASA Technical Reports Server (NTRS)

    Cochran, Donna J.; Boutte, Alvin J.; Chen, Dakai; Pellish, Jonathan A.; Ladbury, Raymond L.; Casey, Megan C.; Campola, Michael J.; Wilcox, Edward P.; Obryan, Martha V.; LaBel, Kenneth A.; hide

    2012-01-01

    Vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage is studied. Devices tested include optoelectronics, digital, analog, linear, and hybrid devices.

  10. A simplified technique for delivering total body irradiation (TBI) with improved dose homogeneity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yao Rui; Bernard, Damian; Turian, Julius

    2012-04-15

    Purpose: Total body irradiation (TBI) with megavoltage photon beams has been accepted as an important component of management for a number of hematologic malignancies, generally as part of bone marrow conditioning regimens. The purpose of this paper is to present and discuss the authors' TBI technique, which both simplifies the treatment process and improves the treatment quality. Methods: An AP/PA TBI treatment technique to produce uniform dose distributions using sequential collimator reductions during each fraction was implemented, and a sample calculation worksheet is presented. Using this methodology, the dosimetric characteristics of both 6 and 18 MV photon beams, including lungmore » dose under cerrobend blocks was investigated. A method of estimating midplane lung doses based on measured entrance and exit doses was proposed, and the estimated results were compared with measurements. Results: Whole body midplane dose uniformity of {+-}10% was achieved with no more than two collimator-based beam modulations. The proposed model predicted midplane lung doses 5% to 10% higher than the measured doses for 6 and 18 MV beams. The estimated total midplane doses were within {+-}5% of the prescribed midplane dose on average except for the lungs where the doses were 6% to 10% lower than the prescribed dose on average. Conclusions: The proposed TBI technique can achieve dose uniformity within {+-}10%. This technique is easy to implement and does not require complicated dosimetry and/or compensators.« less

  11. How Long Can the Hubble Space Telescope Operate Reliably? A Total Dose Perspective

    NASA Technical Reports Server (NTRS)

    Xapsos, M. A.; Stauffer, C.; Jordan, T.; Poivey, C.; Haskins, D. N.; Lum, G.; Pergosky, A. M.; Smith, D. C.; LaBel, K. A.

    2014-01-01

    The Hubble Space Telescope has been at the forefront of discoveries in the field of astronomy for more than 20 years. It was the first telescope designed to be serviced in space and the last such servicing mission occurred in May 2009. The question of how much longer this valuable resource can continue to return science data remains. In this paper a detailed analysis of the total dose exposure of electronic parts at the box level is performed using solid angle sectoring/3-dimensional ray trace and Monte Carlo radiation transport simulations. Results are related to parts that have been proposed as possible total dose concerns. The spacecraft subsystem that appears to be at the greatest risk for total dose failure is identified. This is discussed with perspective on the overall lifetime of the spacecraft.

  12. Dosimetric evaluation of total marrow irradiation using 2 different planning systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nalichowski, Adrian, E-mail: nalichoa@karmanos.org; Eagle, Don G.; Burmeister, Jay

    This study compared 2 different treatment planning systems (TPSs) for quality and efficiency of total marrow irradiation (TMI) plans. The TPSs used in this study were VOxel-Less Optimization (VoLO) (Accuray Inc, Sunnyvale, CA) using helical dose delivery on a Tomotherapy Hi-Art treatment unit and Eclipse (Varian Medical Systems Inc, Palo Alto, CA) using volumetric modulated arc therapy (VMAT) dose delivery on a Varian iX treatment unit. A total dose of 1200 cGy was prescribed to cover 95% of the planning target volume (PTV). The plans were optimized and calculated based on a single CT data and structure set using themore » Alderson Rando phantom (The Phantom Laboratory, Salem, NY) and physician contoured target and organ at risk (OAR) volumes. The OARs were lungs, heart, liver, kidneys, brain, and small bowel. The plans were evaluated based on plan quality, time to optimize the plan and calculate the dose, and beam on time. The resulting mean and maximum doses to the PTV were 1268 and 1465 cGy for VoLO and 1284 and 1541 cGy for Eclipse, respectively. For 5 of 6 OAR structures the VoLO system achieved lower mean and D10 doses ranging from 22% to 52% and 3% to 44%, respectively. Total computational time including only optimization and dose calculation were 0.9 hours for VoLO and 3.8 hours for Eclipse. These times do not include user-dependent target delineation and field setup. Both planning systems are capable of creating high-quality plans for total marrow irradiation. The VoLO planning system was able to achieve more uniform dose distribution throughout the target volume and steeper dose fall off, resulting in superior OAR sparing. VoLO's graphics processing unit (GPU)–based optimization and dose calculation algorithm also allowed much faster creation of TMI plans.« less

  13. A cross-sectional observational study to assess inhaler technique in Saudi hospitalized patients with asthma and chronic obstructive pulmonary disease

    PubMed Central

    Ammari, Maha Al; Sultana, Khizra; Yunus, Faisal; Ghobain, Mohammed Al; Halwan, Shatha M. Al

    2016-01-01

    Objectives: To assess the proportion of critical errors committed while demonstrating the inhaler technique in hospitalized patients diagnosed with asthma and chronic obstructive pulmonary disease (COPD). Methods: This cross-sectional observational study was conducted in 47 asthmatic and COPD patients using inhaler devices. The study took place at King Abdulaziz Medical City, Riyadh, Saudi Arabia between September and December 2013. Two pharmacists independently assessed inhaler technique with a validated checklist. Results: Seventy percent of patients made at least one critical error while demonstrating their inhaler technique, and the mean number of critical errors per patient was 1.6. Most patients used metered dose inhaler (MDI), and 73% of MDI users and 92% of dry powder inhaler users committed at least one critical error. Conclusion: Inhaler technique in hospitalized Saudi patients was inadequate. Health care professionals should understand the importance of reassessing and educating patients on a regular basis for inhaler technique, recommend the use of a spacer when needed, and regularly assess and update their own inhaler technique skills. PMID:27146622

  14. Feasibility of a community intervention for the prevention of suicide and alcohol abuse with Yup'ik Alaska Native youth: the Elluam Tungiinun and Yupiucimta Asvairtuumallerkaa studies.

    PubMed

    Mohatt, Gerald V; Fok, Carlotta Ching Ting; Henry, David; Allen, James

    2014-09-01

    The Elluam Tungiinun and Yupiucimta Asvairtuumallerkaa studies evaluated the feasibility of a community intervention to prevent suicide and alcohol abuse among rural Yup'ik Alaska Native youth in two remote communities. The intervention originated in an Indigenous model of protection, and its development used a community based participatory research process. Feasibility assessment aimed to assess the extent to which (1) the intervention could be implemented in rural Alaska Native communities, and (2) the intervention was capable of producing measurable effects. Scales maximally sensitive to change were derived from earlier measurement work, and the study contrasted implementation process and outcomes across the two communities. In one community, medium dose response effects (d = .30-.50), with dose defined as number of intervention activities attended, were observed in the growth of intermediate protective factors and ultimate variables. In the other community, medium dose effects were observed for one intermediate protective factor variable, and small dose effects were observed in ultimate variables. Differences across communities in resources supporting intervention explain these contrasting outcomes. Results suggest implementation in these rural Alaska settings is feasible when sufficient resources are available to sustain high levels of local commitment. In such cases, measureable effects are sufficient to warrant a prevention trial.

  15. Measurement and comparison of skin dose using OneDose MOSFET and Mobile MOSFET for patients with acute lymphoblastic leukemia

    PubMed Central

    Mattar, Essam H.; Hammad, Lina F.; Al-Mohammed, Huda I.

    2011-01-01

    Summary Background Total body irradiation is a protocol used to treat acute lymphoblastic leukemia in patients prior to bone marrow transplant. It is involved in the treatment of the whole body using a large radiation field with extended source-skin distance. Therefore measuring and monitoring the skin dose during the treatment is important. Two kinds of metal oxide semiconductor field effect transistor (OneDose MOSFET and mobile MOSEFT) dosimeter are used during the treatment delivery to measure the skin dose to specific points and compare it with the target prescribed dose. The objective of this study was to compare the variation of skin dose in patients with acute lymphatic leukemia (ALL) treated with total body irradiation (TBI) using OneDose MOSFET detectors and Mobile MOSFET, and then compare both results with the target prescribed dose. Material/Methods The measurements involved 32 patient’s (16 males, 16 females), aged between 14–30 years, with an average age of 22.41 years. One-Dose MOSFET and Mobile MOSFET dosimetry were performed at 10 different anatomical sites on every patient. Results The results showed there was no variation between skin dose measured with OneDose MOSFET and Mobile MOSFET in all patients. Furthermore, the results showed for every anatomical site selected there was no significant difference in the dose delivered using either OneDose MOSFET detector or Mobile MOSFET as compared to the prescribed dose. Conclusions The study concludes that One-Dose MOSFET detectors and Mobile MOSFET both give a direct read-out immediately after the treatment; therefore both detectors are suitable options when measuring skin dose for total body irradiation treatment. PMID:21709641

  16. Measurement and comparison of skin dose using OneDose MOSFET and Mobile MOSFET for patients with acute lymphoblastic leukemia.

    PubMed

    Mattar, Essam H; Hammad, Lina F; Al-Mohammed, Huda I

    2011-07-01

    Total body irradiation is a protocol used to treat acute lymphoblastic leukemia in patients prior to bone marrow transplant. It is involved in the treatment of the whole body using a large radiation field with extended source-skin distance. Therefore measuring and monitoring the skin dose during the treatment is important. Two kinds of metal oxide semiconductor field effect transistor (OneDose MOSFET and mobile MOSEFT) dosimeter are used during the treatment delivery to measure the skin dose to specific points and compare it with the target prescribed dose. The objective of this study was to compare the variation of skin dose in patients with acute lymphatic leukemia (ALL) treated with total body irradiation (TBI) using OneDose MOSFET detectors and Mobile MOSFET, and then compare both results with the target prescribed dose. The measurements involved 32 patient's (16 males, 16 females), aged between 14-30 years, with an average age of 22.41 years. One-Dose MOSFET and Mobile MOSFET dosimetry were performed at 10 different anatomical sites on every patient. The results showed there was no variation between skin dose measured with OneDose MOSFET and Mobile MOSFET in all patients. Furthermore, the results showed for every anatomical site selected there was no significant difference in the dose delivered using either OneDose MOSFET detector or Mobile MOSFET as compared to the prescribed dose. The study concludes that One-Dose MOSFET detectors and Mobile MOSFET both give a direct read-out immediately after the treatment; therefore both detectors are suitable options when measuring skin dose for total body irradiation treatment.

  17. Enhancing the open space of Jabodetabek area, Indonesia

    NASA Astrophysics Data System (ADS)

    Wartaman, A. S.; Situmorang, R.; Suharto, B. B.

    2018-01-01

    Jabodetabek area is planned to be developed as a sustainable development region. The Government of Indonesia (GoI) committed in Paris Conference that the target of GHG emissions would be reduced by 29% up to 2030 with her own efforts and by 41% with supported by international assistance. This research attempts to apply specific methods such as stratified planting method to improve the quality of green open space by increasing the absorbed carbon level. The study showed that with the planting vegetation of stratified model, the total capacity of the mainland to absorb CO2 gas is quite significant increase with approximately 20% compared to that of homogeneous vegetation. The stratified planting model is worthwhile to achieve the commitment of the GoI mentioned above.

  18. Effect of Localizer Radiography Projection on Organ Dose at Chest CT with Automatic Tube Current Modulation.

    PubMed

    Saltybaeva, Natalia; Krauss, Andreas; Alkadhi, Hatem

    2017-03-01

    Purpose To calculate the effect of localizer radiography projections to the total radiation dose, including both the dose from localizer radiography and that from subsequent chest computed tomography (CT) with tube current modulation (TCM). Materials and Methods An anthropomorphic phantom was scanned with 192-section CT without and with differently sized breast attachments. Chest CT with TCM was performed after one localizer radiographic examination with anteroposterior (AP) or posteroanterior (PA) projections. Dose distributions were obtained by means of Monte Carlo simulations based on acquired CT data. For Monte Carlo simulations of localizer radiography, the tube position was fixed at 0° and 180°; for chest CT, a spiral trajectory with TCM was used. The effect of tube start angles on dose distribution was investigated with Monte Carlo simulations by using TCM curves with fixed start angles (0°, 90°, and 180°). Total doses for lungs, heart, and breast were calculated as the sum of the dose from localizer radiography and CT. Image noise was defined as the standard deviation of attenuation measured in 14 circular regions of interest. The Wilcoxon signed rank test, paired t test, and Friedman analysis of variance were conducted to evaluate differences in noise, TCM curves, and organ doses, respectively. Results Organ doses from localizer radiography were lower when using a PA instead of an AP projection (P = .005). The use of a PA projection resulted in higher TCM values for chest CT (P < .001) owing to the higher attenuation (P < .001) and thus resulted in higher total organ doses for all investigated phantoms and protocols (P < .001). Noise in CT images was lower with PA localizer radiography than with AP localizer radiography (P = .03). The use of an AP projection allowed for total dose reductions of 16%, 15%, and 12% for lungs, breast, and heart, respectively. Differences in organ doses were not related to tube start angles (P = .17). Conclusion The total organ doses are higher when using PA projection localizer radiography owing to higher TCM values, whereas the organ doses from PA localizer radiography alone are lower. Thus, PA localizer radiography should be used in combination with reduced reference tube current at subsequent chest CT. © RSNA, 2016 Online supplemental material is available for this article.

  19. The Role of Cellular Proliferation in Adipogenic Differentiation of Human Adipose Tissue-Derived Mesenchymal Stem Cells.

    PubMed

    Marquez, Maribel P; Alencastro, Frances; Madrigal, Alma; Jimenez, Jossue Loya; Blanco, Giselle; Gureghian, Alex; Keagy, Laura; Lee, Cecilia; Liu, Robert; Tan, Lun; Deignan, Kristen; Armstrong, Brian; Zhao, Yuanxiang

    2017-11-01

    Mitotic clonal expansion has been suggested as a prerequisite for adipogenesis in murine preadipocytes, but the precise role of cell proliferation during human adipogenesis is unclear. Using adipose tissue-derived human mesenchymal stem cells as an in vitro cell model for adipogenic study, a group of cell cycle regulators, including Cdk1 and CCND1, were found to be downregulated as early as 24 h after adipogenic initiation and consistently, cell proliferation activity was restricted to the first 48 h of adipogenic induction. Cell proliferation was either further inhibited using siRNAs targeting cell cycle genes or enhanced by supplementing exogenous growth factor, basic fibroblast growth factor (bFGF), at specific time intervals during adipogenesis. Expression knockdown of Cdk1 at the initiation of adipogenic induction resulted in significantly increased adipocytes, even though total number of cells was significantly reduced compared to siControl-treated cells. bFGF stimulated proliferation throughout adipogenic differentiation, but exerted differential effect on adipogenic outcome at different phases, promoting adipogenesis during mitotic phase (first 48 h), but significantly inhibiting adipogenesis during adipogenic commitment phase (days 3-6). Our results demonstrate that cellular proliferation is counteractive to adipogenic commitment in human adipogenesis. However, cellular proliferation stimulation can be beneficial for adipogenesis during the mitotic phase by increasing the population of cells capable of committing to adipocytes before adipogenic commitment.

  20. Total Ionizing Dose Test of Microsemi's Silicon Switching Transistors JANTXV2N2222AUB and 2N2907AUB

    NASA Technical Reports Server (NTRS)

    Campola, M.; Freeman, B.; Yau, K.

    2017-01-01

    Microsemi's silicon switching transistors, JANTXV2N2222AUB and 2N2907AUB, were tested for total ionizing dose (TID) response beginning on July 11, 2016. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) could be determined.

  1. Ninth Annual NASA/Contractors Conference on Quality and Productivity. World Class Excellence: The Journey Continues. Keynote presentations

    NASA Technical Reports Server (NTRS)

    Templeton, Geoffrey B. (Editor)

    1992-01-01

    This coference provided an excellent forum for the members of the NASA community to share their experience and expertise in an effort to continuously improve the quality of the US space program. The topics covered include the following: NASA's approach to continual improvement; commitment to total quality; total quality at AlliedSignal Aerospace; organizational TQM; recognition of the 1992 Low Trophy Finalists; announcement of the 1992 Low Trophy Recipients; and the changing face of aerospace contracting.

  2. PBDE exposure from food in Ireland: optimising data exploitation in probabilistic exposure modelling.

    PubMed

    Trudel, David; Tlustos, Christina; Von Goetz, Natalie; Scheringer, Martin; Hungerbühler, Konrad

    2011-01-01

    Polybrominated diphenyl ethers (PBDEs) are a class of brominated flame retardants added to plastics, polyurethane foam, electronics, textiles, and other products. These products release PBDEs into the indoor and outdoor environment, thus causing human exposure through food and dust. This study models PBDE dose distributions from ingestion of food for Irish adults on congener basis by using two probabilistic and one semi-deterministic method. One of the probabilistic methods was newly developed and is based on summary statistics of food consumption combined with a model generating realistic daily energy supply from food. Median (intermediate) doses of total PBDEs are in the range of 0.4-0.6 ng/kg(bw)/day for Irish adults. The 97.5th percentiles of total PBDE doses lie in a range of 1.7-2.2 ng/kg(bw)/day, which is comparable to doses derived for Belgian and Dutch adults. BDE-47 and BDE-99 were identified as the congeners contributing most to estimated intakes, accounting for more than half of the total doses. The most influential food groups contributing to this intake are lean fish and salmon which together account for about 22-25% of the total doses.

  3. Violent and Nonviolent Youth Offenders: Preliminary Evidence on Group Subtypes.

    PubMed

    Lai, Violet; Zeng, Gerald; Chu, Chi Meng

    2016-07-01

    Youth violence is a costly social problem. This study compared the risk and needs of nonviolent youth offenders, with those who had committed violent offenses only (violent only) and those who had committed violent and nonviolent offenses (violent plus) to determine whether violent youth were a different "type" from nonviolent youth. The case files of 3,744 youth offenders (3,327 males and 417 females, between 12 and 18 years old) were retrospectively coded, before official recidivism records were obtained. Multivariate analysis of variance (MANOVA), χ 2 , and Cox regressions were conducted. Violent-plus youth were younger; higher in their total risk and all criminogenic needs; more likely to have several noncriminogenic needs; and at higher risk of any reoffending, violent reoffending, and nonviolent reoffending than nonviolent youth. Violent-only youth had the same total risk and risk of general and violent recidivism as nonviolent offenders but presented different criminogenic and noncriminogenic needs and risk of nonviolent recidivism. Compared to violent-only youth, violent-plus youth were younger, had higher total risk and criminogenic needs on five domains, were more likely to have several noncriminogenic needs, and were at higher risk of all types of reoffending (except sexual reoffending), suggesting subtypes of violent youth offenders. The implication is that nonviolent and violent youth offenders require different dosage and types of intervention.

  4. Total Ionizing Dose and Displacement Damage Compendium of Candidate Spacecraft Electronics for NASA

    NASA Technical Reports Server (NTRS)

    Cochran, Donna J.; Chen, Dakai; Oldham, Timothy R.; Sanders, Anthony B.; Kim, Hak S.; Campola, Michael J.; Buchner, Stephen P.; LaBel, Kenneth A.; Marshall, Cheryl J.; Pellish, Jonathan A.; hide

    2010-01-01

    Vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage is studied. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices.

  5. Clinical outcomes and cost minimization with an alternative dosing regimen for meropenem in a community hospital.

    PubMed

    Patel, Gita Wasan; Duquaine, Susan M; McKinnon, Peggy S

    2007-12-01

    To compare outcomes and cost for the traditional United States Food and Drug Administration-approved dosing regimen for meropenem versus an alternative dosing regimen providing similar pharmacodynamic exposure with a lower total daily dose. Retrospective cohort study with a cost-minimization analysis. A 417-bed, privately owned community hospital. One hundred patients who received meropenem 1 g every 8 or 12 hours (traditional dosing regimen) between January 1 and September 30, 2004 (historical controls), and 192 patients who received meropenem 500 mg every 6 or 8 hours (alternative dosing regimen) between October 1, 2004, and September 30, 2005. Demographic and clinical data were collected for all patients. Cost-minimization analysis was performed by using the drug acquisition cost for meropenem. Demographics, sources of infection, distributions of organisms, and Charlson Comorbidity Index scores were similar between patients in the traditionally and alternatively dosed groups. Concomitant therapy, duration of therapy, success rates, lengths of stay, and in-hospital mortality rates were also similar between groups. Median time to the resolution of symptoms was 3 days for traditional dosing and 1.5 days for alternative dosing (p<0.0001). A logistic regression model including the dosing strategy showed that only polymicrobial infections and sepsis were associated with increased failure rates. The median cost for antibiotics was $439.05/patient for traditional dosing and $234.08/patient for alternative dosing (p<0.0001). An alternative dosing regimen for meropenem with a lower total daily dose yielded patient outcomes, including success rates and duration of therapy, equivalent to those of the traditional dosing regimen. Alternative dosing decreased total drug exposure, costs for antibiotics, and time to the resolution of infections.

  6. Effect of Direct-Fed Microbial Dosage on the Fecal Concentrations of Enterohemorrhagic Escherichia coli in Feedlot Cattle.

    PubMed

    Luedtke, Brandon E; Bosilevac, Joseph M; Harhay, Dayna M; Arthur, Terrance M

    2016-04-01

    Contamination of beef products by Shiga toxin-producing Escherichia coli is a concern for food safety with a particular subset, the enterohemorrhagic E. coli (EHEC), being the most relevant to human disease. To mitigate food safety risks, preharvest intervention strategies have been implemented with the aim to reduce EHEC in cattle. One class of interventions that has been widely used in feedlots is direct-fed microbials (DFMs), which can contain various dosing rates of probiotic bacteria. Here we compare the use of two different doses of a commercially available DFM on total EHEC load in a commercial feedlot setting. The DFMs used were the standard 10(9) Propionibacterium freudenreichii and 10(6) Lactobacillus acidophilus colony forming units (CFUs)/head/day dose of Bovamine(®) (Nutrition Physiology Company, Guymon, OK) and the higher dose, Bovamine Defend™ (Nutrition Physiology Company), which is dosed at 10(9) P. freudenreichii and 10(9) Lactobacillus acidophilus CFUs/head/day. To analyze the total EHEC fecal concentration, 2200 head of cattle were assigned a DFM feed regimen lasting approximately 5 months. At harvest, 480 head of cattle were sampled using rectoanal mucosal swabs. A quantitative polymerase chain reaction assay targeting ecf1 was used to enumerate the total EHEC fecal concentration for 240 head fed the low-dose DFM and 240 head fed the high-dose DFM. No significant difference (p > 0.05) in the fecal concentration of total EHEC was observed between the two doses. This suggests that using an increased dosage provides no additional reduction in the total EHEC fecal concentration of feedlot cattle compared to the standard dosage.

  7. Patient dose analysis in total body irradiation through in vivo dosimetry.

    PubMed

    Ganapathy, K; Kurup, P G G; Murali, V; Muthukumaran, M; Bhuvaneshwari, N; Velmurugan, J

    2012-10-01

    Total body irradiation (TBI) is a special radiotherapy technique, administered prior to bone marrow transplantation. Due to the complex nature of the treatment setup, in vivo dosimetry for TBI is mandatory to ensure proper delivery of the intended radiation dose throughout the body. Lithium fluoride (LiF) TLD-100 chips are used for the TBI in vivo dosimetry. Results obtained from the in vivo dosimetry of 20 patients are analyzed. Results obtained from forehead, abdomen, pelvis, and mediastinum showed a similar pattern with the average measured dose from 96 to 97% of the prescription dose. Extremities and chest received a dose greater than the prescription dose in many instances (more than 20% of measurements). Homogeneous dose delivery to the whole body is checked by calculating the mean dose with standard deviation for each fraction. Reasons for the difference between prescription dose and measured dose for each site are discussed. Dose homogeneity within ±10% is achieved using our in-house TBI protocol.

  8. Patient dose analysis in total body irradiation through in vivo dosimetry

    PubMed Central

    Ganapathy, K.; Kurup, P. G. G.; Murali, V.; Muthukumaran, M.; Bhuvaneshwari, N.; Velmurugan, J.

    2012-01-01

    Total body irradiation (TBI) is a special radiotherapy technique, administered prior to bone marrow transplantation. Due to the complex nature of the treatment setup, in vivo dosimetry for TBI is mandatory to ensure proper delivery of the intended radiation dose throughout the body. Lithium fluoride (LiF) TLD-100 chips are used for the TBI in vivo dosimetry. Results obtained from the in vivo dosimetry of 20 patients are analyzed. Results obtained from forehead, abdomen, pelvis, and mediastinum showed a similar pattern with the average measured dose from 96 to 97% of the prescription dose. Extremities and chest received a dose greater than the prescription dose in many instances (more than 20% of measurements). Homogeneous dose delivery to the whole body is checked by calculating the mean dose with standard deviation for each fraction. Reasons for the difference between prescription dose and measured dose for each site are discussed. Dose homogeneity within ±10% is achieved using our in-house TBI protocol. PMID:23293453

  9. Studies of foetal death and foetal weight in guinea pigs fed polychlorinated biphenyls (PCB).

    PubMed

    Brunström, B; Kihlström, I; Lundkvist, U

    1982-02-01

    Pregnant guinea pigs were fed a total dose of 100 mg of the commercial PCB preparation Clophen A50 during days 16 to 60 of gestation. This treatment caused severe foetal, but no maternal, death. Contrarily, a total dose of 25 mg or 100 mg of 2,2',4,4',5,5'-hexachlorobiphenyl (HCB) did not cause foetal death in the guinea pig. The prenatal growth rate was increased by a total dose of 25 mg, but not by 100 mg, of HCB.

  10. Carbon choices determine US cities committed to futures below sea level

    PubMed Central

    Strauss, Benjamin H.; Kulp, Scott; Levermann, Anders

    2015-01-01

    Anthropogenic carbon emissions lock in long-term sea-level rise that greatly exceeds projections for this century, posing profound challenges for coastal development and cultural legacies. Analysis based on previously published relationships linking emissions to warming and warming to rise indicates that unabated carbon emissions up to the year 2100 would commit an eventual global sea-level rise of 4.3–9.9 m. Based on detailed topographic and population data, local high tide lines, and regional long-term sea-level commitment for different carbon emissions and ice sheet stability scenarios, we compute the current population living on endangered land at municipal, state, and national levels within the United States. For unabated climate change, we find that land that is home to more than 20 million people is implicated and is widely distributed among different states and coasts. The total area includes 1,185–1,825 municipalities where land that is home to more than half of the current population would be affected, among them at least 21 cities exceeding 100,000 residents. Under aggressive carbon cuts, more than half of these municipalities would avoid this commitment if the West Antarctic Ice Sheet remains stable. Similarly, more than half of the US population-weighted area under threat could be spared. We provide lists of implicated cities and state populations for different emissions scenarios and with and without a certain collapse of the West Antarctic Ice Sheet. Although past anthropogenic emissions already have caused sea-level commitment that will force coastal cities to adapt, future emissions will determine which areas we can continue to occupy or may have to abandon. PMID:26460051

  11. Carbon choices determine US cities committed to futures below sea level.

    PubMed

    Strauss, Benjamin H; Kulp, Scott; Levermann, Anders

    2015-11-03

    Anthropogenic carbon emissions lock in long-term sea-level rise that greatly exceeds projections for this century, posing profound challenges for coastal development and cultural legacies. Analysis based on previously published relationships linking emissions to warming and warming to rise indicates that unabated carbon emissions up to the year 2100 would commit an eventual global sea-level rise of 4.3-9.9 m. Based on detailed topographic and population data, local high tide lines, and regional long-term sea-level commitment for different carbon emissions and ice sheet stability scenarios, we compute the current population living on endangered land at municipal, state, and national levels within the United States. For unabated climate change, we find that land that is home to more than 20 million people is implicated and is widely distributed among different states and coasts. The total area includes 1,185-1,825 municipalities where land that is home to more than half of the current population would be affected, among them at least 21 cities exceeding 100,000 residents. Under aggressive carbon cuts, more than half of these municipalities would avoid this commitment if the West Antarctic Ice Sheet remains stable. Similarly, more than half of the US population-weighted area under threat could be spared. We provide lists of implicated cities and state populations for different emissions scenarios and with and without a certain collapse of the West Antarctic Ice Sheet. Although past anthropogenic emissions already have caused sea-level commitment that will force coastal cities to adapt, future emissions will determine which areas we can continue to occupy or may have to abandon.

  12. Evolution of opinions on social networks in the presence of competing committed groups.

    PubMed

    Xie, Jierui; Emenheiser, Jeffrey; Kirby, Matthew; Sreenivasan, Sameet; Szymanski, Boleslaw K; Korniss, Gyorgy

    2012-01-01

    Public opinion is often affected by the presence of committed groups of individuals dedicated to competing points of view. Using a model of pairwise social influence, we study how the presence of such groups within social networks affects the outcome and the speed of evolution of the overall opinion on the network. Earlier work indicated that a single committed group within a dense social network can cause the entire network to quickly adopt the group's opinion (in times scaling logarithmically with the network size), so long as the committed group constitutes more than about 10% of the population (with the findings being qualitatively similar for sparse networks as well). Here we study the more general case of opinion evolution when two groups committed to distinct, competing opinions A and B, and constituting fractions pA and pB of the total population respectively, are present in the network. We show for stylized social networks (including Erdös-Rényi random graphs and Barabási-Albert scale-free networks) that the phase diagram of this system in parameter space (pA,pB) consists of two regions, one where two stable steady-states coexist, and the remaining where only a single stable steady-state exists. These two regions are separated by two fold-bifurcation (spinodal) lines which meet tangentially and terminate at a cusp (critical point). We provide further insights to the phase diagram and to the nature of the underlying phase transitions by investigating the model on infinite (mean-field limit), finite complete graphs and finite sparse networks. For the latter case, we also derive the scaling exponent associated with the exponential growth of switching times as a function of the distance from the critical point.

  13. [Occupational mental health and job satisfaction in university teachers in Shenyang, China].

    PubMed

    Li, M Y; Wang, Z Y; Wu, H; Wang, J N; Wang, L

    2017-02-20

    Objective: To investigate the current status of occupational mental health and job satisfaction in university teachers in Shenyang, China and related influencing factors. Methods: A total of 1500 teachers from 6 universities in Shenyang were randomly selected as study subjects from November 2013 to January 2014. Self-administered questionnaires were used to investigate mental health, including effort-reward imbalance questionnaire, Minnesota Satisfaction Questionnaire, Center for Epidemiological Survey-Depression Scale, and Psychological Capital Questionnaire. Results: Of all teachers, 58.9% had depressive symptoms. Depressive symptoms in university teachers were negatively correlated with the scores of psychological capital, supervisory commitment, and perceived organizational support ( r =-0.461, -0.306, and -0.366, all P <0.01) and were positively correlated with the score of occupational stress ( r =0.414, P <0.01) . Job satisfaction was positively correlated with psychological capital, perceived organizational support, and supervisory commitment ( r =0.650, 0.715, and 0.636, all P <0.01) and negatively correlated with occupational stress ( r =-0.475, P <0.01) . The direct effects of occupational stress, perceived organizational support, and supervisory commitment on job satisfaction were -0.30, 0.26, and 0.14, respectively, and their indirect effects were -0.0176, 0.0656, and 0.0368, respectively. The direct effects of occupational stress, perceived organizational support, and supervisory commitment on depressive symptoms were 0.20, -0.08, and -0.05, respectively, and their indirect effects was 0.033, -0.123, and -0.069, respectively. Conclusion: Occupational mental health is closely associated with job satisfaction in university teachers in Shenyang, and psychological capital has a mediating effect on perceived organizational support, supervisory commitment, occupational stress, job satisfaction, and depressive symptoms.

  14. Self Esteem and Organizational Commitment Among Health Information Management Staff in Tertiary Care Hospitals in Tehran

    PubMed Central

    Sadoughi, Farahnaz; Ebrahimi, Kamal

    2015-01-01

    Background: Self esteem (SE) and organizational commitment (OC) have significant impact on the quality of work life. Aim: This study aims to gain a better understanding of the relationships between SE and OC among health information management staff in tertiary care hospitals in Tehran (Iran). Methods: This was a descriptive correlational and cross sectional study conducted on the health information management staff of tertiary care hospitals in Tehran, Iran. A total of 155 participants were randomly selected from 400 staff. Data were collected by two standard questionnaires. The SE and OC was measured using Eysenck SE scale and Meyer and Allen’s three component model, respectively. The collected data were analyzed with the SPSS (version 16) using statistical tests of of independent T-test, Pearson Correlation coefficient, one way ANOVA and F tests. Results: The OC and SE of the employees’ were 67.8, out of 120 (weak and 21.0 out of 30 (moderate), respectively. The values for affective commitment, normative commitment, and continuance commitment were respectively 21.3 out of 40 (moderate), 23.9 out of 40 (moderate), and 22.7 out of 40 (moderate). The Pearson correlation coefficient test showed a significant OC and SE was statistically significant (P<0.05). The one way ANOVA test (P<0.05) did not show any significant difference between educational degree and work experience with SE and OC. Conclusion: This research showed that SE and OC are moderate. SE and OC have strong correlation with turnover, critical thinking, job satisfaction, and individual and organizational improvement. Therefore, applying appropriate human resource policies is crucial to reinforce these measures. PMID:25716374

  15. Evolution of Opinions on Social Networks in the Presence of Competing Committed Groups

    PubMed Central

    Xie, Jierui; Emenheiser, Jeffrey; Kirby, Matthew; Sreenivasan, Sameet; Szymanski, Boleslaw K.; Korniss, Gyorgy

    2012-01-01

    Public opinion is often affected by the presence of committed groups of individuals dedicated to competing points of view. Using a model of pairwise social influence, we study how the presence of such groups within social networks affects the outcome and the speed of evolution of the overall opinion on the network. Earlier work indicated that a single committed group within a dense social network can cause the entire network to quickly adopt the group's opinion (in times scaling logarithmically with the network size), so long as the committed group constitutes more than about of the population (with the findings being qualitatively similar for sparse networks as well). Here we study the more general case of opinion evolution when two groups committed to distinct, competing opinions and , and constituting fractions and of the total population respectively, are present in the network. We show for stylized social networks (including Erdös-Rényi random graphs and Barabási-Albert scale-free networks) that the phase diagram of this system in parameter space consists of two regions, one where two stable steady-states coexist, and the remaining where only a single stable steady-state exists. These two regions are separated by two fold-bifurcation (spinodal) lines which meet tangentially and terminate at a cusp (critical point). We provide further insights to the phase diagram and to the nature of the underlying phase transitions by investigating the model on infinite (mean-field limit), finite complete graphs and finite sparse networks. For the latter case, we also derive the scaling exponent associated with the exponential growth of switching times as a function of the distance from the critical point. PMID:22448238

  16. Understanding and Supporting Adolescents' Mental Toughness in an Education Context

    ERIC Educational Resources Information Center

    McGeown, Sarah; Putwain, Dave; St. Clair-Thompson, Helen; Clough, Peter

    2017-01-01

    This study sought to explore the concept of mental toughness (comprising the attributes challenge, commitment, control, and confidence) from the perceptions of adolescents, to better understand their views on these attributes and the extent to which each were regarded as important within an educational setting. In total, 54 adolescents (31 female)…

  17. Strategies for Implementation: The El Camino TQM Story.

    ERIC Educational Resources Information Center

    Schauerman, Sam; Peachy, Burt

    In spring 1989, a group of 33 administrators, supervisors, faculty, and staff from El Camino College (ECC) in Torrance, California, attended 10 days of training in Total Quality Management (TQM) tools and techniques. The subsequent implementation of TQM at ECC included the following six phases: (1) establishing a Campus Commitment to Excellence…

  18. No Place for Kids: The Case for Reducing Juvenile Incarceration

    ERIC Educational Resources Information Center

    Mendel, Richard A.

    2011-01-01

    States confine juvenile offenders in many types of facilities, including group homes, residential treatment centers, boot camps, wilderness programs, or country-run youth facilities (some of them locked, others secured only through staff supervision). But the largest share of committed youth--about 40 percent of the total--are held in locked…

  19. Depression among Adolescents in Northern Ireland.

    ERIC Educational Resources Information Center

    Donnelly, Michael

    1995-01-01

    Examines the nature and distribution of self-reported depression among a sample of 887 students in Northern Ireland. Findings indicate that 12% of the total sample could be defined as depressed, and approximately 4% reported that they wanted to commit suicide. Significant sex or school form associations were not found, except in one form where a…

  20. Developmental Factors Related to Deviant Sexual Preferences in Child Molesters

    ERIC Educational Resources Information Center

    Lussier, Patrick; Beauregard, Eric; Proulx, Jean; Nicole, Alexandre

    2005-01-01

    The aim of this study was to investigate the relationship between developmental factors and deviant sexual preferences in child molesters. In total, 146 adult males having committed a sexual offence against a child were included in the study. Three types of factors were investigated: negative experiences during childhood, behavior problems during…

  1. On the People's Wavelength: Communications for Social Change.

    ERIC Educational Resources Information Center

    Black, Maggie, Ed.

    1982-01-01

    Articles collected in this issue of UNICEF News deal with different aspects of the theme of communication in development programs. Specifically, topics covered include (1) communication as a total process and the role of communication in overcoming obstacles to social change; (2) a village education and resource center, in Bangladesh, committed to…

  2. The Elyria Schools First: An Initiative To Unleash a Community's Potential Empowering Children To Learn.

    ERIC Educational Resources Information Center

    Elyria City Board of Education, OH.

    Total Quality Management (TQM) is a process and strategy designed to improve an organization's effectiveness and efficiency. The Elyria Schools, named as Ohio's model urban school district in 1991, uses TQM to implement updated strategic goals through a process emphasizing teamwork, best knowledge, prevention, and commitment to continuous…

  3. The Strategic Design Inquiry: A Formal Methodology For Approaching, Designing, Integrating, And Articulating National Strategy

    DTIC Science & Technology

    2014-04-01

    15 Figure 4: Example cognitive map ... map , aligning planning efforts throughout the government. Even after strategy implementation, SDI calls for continuing, iterative learning and...the design before total commitment to it. Capturing this analysis on a cognitive map allows strategists to articulate a design to government

  4. Gender Symmetry in the Self-Reporting of Intimate Partner Violence

    ERIC Educational Resources Information Center

    Chan, Ko Ling

    2012-01-01

    Research has not conclusively determined whether men and women are equally likely to commit intimate partner violence (IPV). One explanation for the disparity in previous findings may be gender-based differences in reporting styles. The present study investigated whether there was any gender difference in self-reported IPV prevalence. A total of…

  5. Adult Education Regional Planning

    ERIC Educational Resources Information Center

    California Community Colleges, Chancellor's Office, 2015

    2015-01-01

    For more than one hundred and fifty years, until 2008, California was an undisputed national leader in its commitment to adult education. The state's investment in adult learners topped $750 million, a sum greater than the combined total of every other state in the nation. However, for the past several years recession and fiscal crisis have left…

  6. Educational Trends and U.S. Commitments Since the Brown Decision.

    ERIC Educational Resources Information Center

    Clark, Kenneth

    The Supreme Court's landmark Brown decision changed the total pattern of race relations in the United States and helped to solidify the foundations of American democracy for the benefit of all Americans. Ironically, although the specific issue which resulted in the Brown decision was concerned with the constitutionality of racially segregated…

  7. Sodium bicarbonate use and the risk of hypernatremia in thoracic aortic surgical patients with metabolic acidosis following deep hypothermic circulatory arrest

    PubMed Central

    Ghadimi, Kamrouz; Gutsche, Jacob T.; Ramakrishna, Harish; Setegne, Samuel L.; Jackson, Kirk R.; Augoustides, John G.; Ochroch, E. Andrew; Weiss, Stuart J.; Bavaria, Joseph E.; Cheung, Albert T.

    2016-01-01

    Objective: Metabolic acidosis after deep hypothermic circulatory arrest (DHCA) for thoracic aortic operations is commonly managed with sodium bicarbonate (NaHCO3). The purpose of this study was to determine the relationships between total NaHCO3 dose and the severity of metabolic acidosis, duration of mechanical ventilation, duration of vasoactive infusions, and Intensive Care Unit (ICU) or hospital length of stay (LOS). Methods: In a single center, retrospective study, 87 consecutive elective thoracic aortic operations utilizing DHCA, were studied. Linear regression analysis was used to test for the relationships between the total NaHCO3 dose administered through postoperative day 2, clinical variables, arterial blood gas values, and short-term clinical outcomes. Results: Seventy-five patients (86%) received NaHCO3. Total NaHCO3 dose averaged 136 ± 112 mEq (range: 0.0–535 mEq) per patient. Total NaHCO3 dose correlated with minimum pH (r = 0.41, P < 0.0001), minimum serum bicarbonate (r = −0.40, P < 0.001), maximum serum lactate (r = 0.46, P = 0.007), duration of metabolic acidosis (r = 0.33, P = 0.002), and maximum serum sodium concentrations (r = 0.29, P = 0.007). Postoperative hypernatremia was present in 67% of patients and peaked at 12 h following DHCA. Eight percent of patients had a serum sodium ≥ 150 mEq/L. Total NaHCO3 dose did not correlate with anion gap, serum chloride, not the duration of mechanical ventilator support, vasoactive infusions, ICU or hospital LOS. Conclusion: Routine administration of NaHCO3 was common for the management of metabolic acidosis after DHCA. Total dose of NaHCO3 was a function of the severity and duration of metabolic acidosis. NaHCO3 administration contributed to postoperative hypernatremia that was often severe. The total NaHCO3 dose administered was unrelated to short-term clinical outcomes. PMID:27397449

  8. Dynamically accumulated dose and 4D accumulated dose for moving tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li Heng; Li Yupeng; Zhang Xiaodong

    2012-12-15

    Purpose: The purpose of this work was to investigate the relationship between dynamically accumulated dose (dynamic dose) and 4D accumulated dose (4D dose) for irradiation of moving tumors, and to quantify the dose uncertainty induced by tumor motion. Methods: The authors established that regardless of treatment modality and delivery properties, the dynamic dose will converge to the 4D dose, instead of the 3D static dose, after multiple deliveries. The bounds of dynamic dose, or the maximum estimation error using 4D or static dose, were established for the 4D and static doses, respectively. Numerical simulations were performed (1) to prove themore » principle that for each phase, after multiple deliveries, the average number of deliveries for any given time converges to the total number of fractions (K) over the number of phases (N); (2) to investigate the dose difference between the 4D and dynamic doses as a function of the number of deliveries for deliveries of a 'pulsed beam'; and (3) to investigate the dose difference between 4D dose and dynamic doses as a function of delivery time for deliveries of a 'continuous beam.' A Poisson model was developed to estimate the mean dose error as a function of number of deliveries or delivered time for both pulsed beam and continuous beam. Results: The numerical simulations confirmed that the number of deliveries for each phase converges to K/N, assuming a random starting phase. Simulations for the pulsed beam and continuous beam also suggested that the dose error is a strong function of the number of deliveries and/or total deliver time and could be a function of the breathing cycle, depending on the mode of delivery. The Poisson model agrees well with the simulation. Conclusions: Dynamically accumulated dose will converge to the 4D accumulated dose after multiple deliveries, regardless of treatment modality. Bounds of the dynamic dose could be determined using quantities derived from 4D doses, and the mean dose difference between the dynamic dose and 4D dose as a function of number of deliveries and/or total deliver time was also established.« less

  9. In vivo semiconductor dosimetry as part of routine quality assurance.

    PubMed

    Millwater, C J; MacLeod, A S; Thwaites, D I

    1998-06-01

    This paper describes the initial physics testing necessary before diodes can be used for in vivo dosimetry as well as the development of a protocol for clinical use in head and neck treatment and the preliminary results acquired. 50 patients were entered into the pilot study. A total of 300 treatment set-ups were measured (184 entrance doses and 116 exit doses). Wedged and unwedged components of each field were measured separately, making the total number of entrance doses 284 and total number of exit doses 207. There was no significant systematic deviation in the measured entrance dose compared with the expected (mean +0.4%, SD 2.7%). Discrepancies between the observed and expected entrance doses of greater than 5% were recorded in 6% (16/284) of measurements. The mean of the measured exit doses was 2.4% lower than expected (SD 4.8%). Discrepancies between the observed and expected exist doses of greater than 5% were recorded in 32% (67/207) of measurements. Possible causes for these discrepancies are discussed. Overall analysis of the data for individual patients suggest that in one patient out of the 50 there may have been a delivered target volume dose discrepancy of greater than 5% (+6.5%). The significance of the results and the implications for routine use are discussed.

  10. Assessment of dose rate to terrestrial biota in the area around coal fired power plant applying ERICA tool and RESRAD BIOTA code.

    PubMed

    Ćujić, Mirjana; Dragović, Snežana

    2018-08-01

    This paper presents the environmental radiation risk assessment based on two software program approaches ERICA Tool (version 1.2) and RESRAD BIOTA (version 1.5) to estimate dose rates to terrestrial biota in the area around the largest coal fired power plant in Serbia. For dose rate assessment software's default reference animals and plants and the best estimated values of activity concentrations of 238 U, 234 U, 234 Th, 232 Th, 230 Th, 226 Ra, 210 Pb, 210 Po, 137 Cs in soil were used. Both approaches revealed the highest contribution to the internal dose rate due to 226 Ra and 210 Po, while 137 Cs contributed the most to the external dose rate. In the investigated area total dose rate to biota derived using ERICA Tool ranged from 0.3 to 14.4 μGy h -1 . The natural radionuclides exhibited significantly higher contribution to the total dose rate than the artificial one. In the investigated area, only dose rate for lichens and bryophytes exceeded ERICA Tool screening value of total dose rate of 10 μGy h -1 suggested as confident that environmental risks are negligible. The assessed total dose rates for reference animals and plants using RESRAD BIOTA were found to be 7 and 3 μGy h -1 , respectively. In RESRAD BIOTA - Level 3, 10 species (Lumbricus terrestris, Rana lessonae, Sciurus vulgaris, Anas platyrhynchos, Lepus europaeus, Vulpes vulpes, Capreolus capreolus, Suss crofa, Quercu srobur, Tilia spp.) representative for the study area were modeled. Among them the highest total dose rate (4.5 μGy h -1 ) was obtained for large mammals. Differences in the predicted dose rates to biota using the two software programs are the consequence of the difference in the values of transfer parameters used to calculate activity concentrations in biota. Doses of ionizing radiation estimated in this study will not exhibit deterministic effects at the population level. Thus, the obtained results indicate no significant radiation impact of coal fired power plant operation on terrestrial biota. This paper confirms the use ERICA Tool and RESRAD BIOTA softwares as flexible and effective means of radiation impact assessment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Recent Total Ionizing Dose and Displacement Damage Compendium of Candidate Electronics for NASA Space Systems

    NASA Technical Reports Server (NTRS)

    Cochran, Donna J.; Boutte, Alvin J.; Campola, Michael J.; Carts, Martin A.; Casey, Megan C.; Chen, Dakai; LaBel, Kenneth A.; Ladbury, Raymond L.; Lauenstein, Jean-Marie; Marshall, Cheryl J.; hide

    2011-01-01

    Vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage is studied. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices.

  12. Comparison of PDR brachytherapy and external beam radiation therapy in the case of breast cancer

    NASA Astrophysics Data System (ADS)

    Teymournia, L.; Berger, D.; Kauer-Dorner, D.; Poljanc, K.; Seitz, W.; Aiginger, H.; Kirisits, C.

    2009-04-01

    Pulsed dose rate brachytherapy (PDR) was compared to external beam radiation therapy (EBRT) in the case of breast cancer. The benefits were figured out by evaluation of dosimetric parameters and calculating the normal tissue complication probability (NTCP). PDR plans were set up for five randomly chosen left-sided breast cancer patients delivering a total dose of 50.4 Gy to the target (dose rate 0.8 Gy h-1). For EBRT five left-sided breast cancer patients were planned using 3D-conformal tangential photon beams with a prescribed total dose of 50 Gy (2 Gy/fraction) to the total breast volume. For plan ranking and NTCP calculation the physical dose was first converted into the biologically effective dose (BED) and then into the normalized total dose (NTD) using the linear quadratic model with an α/β ratio of 3 Gy. In PDR the relative effectiveness (RE) was calculated for each dose bin of the differential dose volume histogram to get the BED. NTCPs were calculated for the ipsilateral lung and the heart as contoured on CT slices based on the Lyman model and the Kutcher reduction scheme. Dosimetric parameters as Vth (percentage of the total volume exceeding a threshold dose) and Jackson's fdam (fraction of the organ damaged) were also used to figure out the benefits. The comparison of calculated NTCPs in PDR and EBRT showed no difference between these two modalities. All values were below 0.01%. fdam derived from EBRT was always higher (mean value 8.95% versus 1.21% for the lung). The mean V10 and V20 of the lung related to BED were 6.32% and 1.72% for PDR versus 11.72% and 9.59% for EBRT. When using dosimetric parameters as Vth and fdam, PDR was mostly superior to EBRT in respect of sparing normal tissues. NTCP calculation as a single method of modality ranking showed a lack of information, especially when normal tissue was exposed to low radiation doses.

  13. High-dose total-body irradiation and autologous marrow reconstitution in dogs: dose-rate-related acute toxicity and fractionation-dependent long-term survival

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deeg, H.J.; Storb, R.; Weiden, P.L.

    1981-11-01

    Beagle dogs treated by total-body irradiation (TBI) were given autologous marrow grafts in order to avoid death from marrow toxicity. Acute and delayed non-marrow toxicities of high single-dose (27 dogs) and fractionated TBI (20 dogs) delivered at 0.05 or 0.1 Gy/min were compared. Fractionated TBI was given in increments of 2 Gy every 6 hr for three increments per day. Acute toxicity and early mortality (<1 month) at identical total irradiation doses were comparable for dogs given fractionated or single-dose TBI. With single-dose TBI, 14, 16, and 18 Gy, respectively, given at 0.05 Gy/min, 0/5, 5/5, and 2/2 dogs diedmore » from acute toxicity; with 10, 12, and 14 Gy, respectively, given at 0.1 Gy/min, 1/5, 4/5, and 5/5 dogs died acutely. With fractionated TBI, 14 and 16 Gy, respectively, given at 0.1 Gy/min, 1/5, 4/5, and 2/2 dogs died auctely. Early deaths were due to radiation enteritis with or without associated septicemia (29 dogs; less than or equal to Day 10). Three dogs given 10 Gy of TBI at 0.1 Gy/min died from bacterial pneumonia; one (Day 18) had been given fractionated and two (Days 14, 22) single-dose TBI. Fifteen dogs survived beyond 1 month; eight of these had single-dose TBI (10-14 Gy) and all died within 7 months of irradiation from a syndrome consisting of hepatic damage, pancreatic fibrosis, malnutrition, wasting, and anemia. Seven of the 15 had fractionated TBI, and only one (14 Gy) died on Day 33 from hepatic failure, whereas 6 (10-14 Gy) are alive and well 250 to 500 days after irradiation. In conclusion, fractionated TBI did not offer advantages over single-dose TBI with regard to acute toxicity and early mortality; rather, these were dependent upon the total dose of TBI. The total acutely tolerated dose was dependent upon the exposure rate; however, only dogs given fractionated TBI became healthy long-term survivors.« less

  14. Development of probabilistic internal dosimetry computer code

    NASA Astrophysics Data System (ADS)

    Noh, Siwan; Kwon, Tae-Eun; Lee, Jai-Ki

    2017-02-01

    Internal radiation dose assessment involves biokinetic models, the corresponding parameters, measured data, and many assumptions. Every component considered in the internal dose assessment has its own uncertainty, which is propagated in the intake activity and internal dose estimates. For research or scientific purposes, and for retrospective dose reconstruction for accident scenarios occurring in workplaces having a large quantity of unsealed radionuclides, such as nuclear power plants, nuclear fuel cycle facilities, and facilities in which nuclear medicine is practiced, a quantitative uncertainty assessment of the internal dose is often required. However, no calculation tools or computer codes that incorporate all the relevant processes and their corresponding uncertainties, i.e., from the measured data to the committed dose, are available. Thus, the objective of the present study is to develop an integrated probabilistic internal-dose-assessment computer code. First, the uncertainty components in internal dosimetry are identified, and quantitative uncertainty data are collected. Then, an uncertainty database is established for each component. In order to propagate these uncertainties in an internal dose assessment, a probabilistic internal-dose-assessment system that employs the Bayesian and Monte Carlo methods. Based on the developed system, we developed a probabilistic internal-dose-assessment code by using MATLAB so as to estimate the dose distributions from the measured data with uncertainty. Using the developed code, we calculated the internal dose distribution and statistical values ( e.g. the 2.5th, 5th, median, 95th, and 97.5th percentiles) for three sample scenarios. On the basis of the distributions, we performed a sensitivity analysis to determine the influence of each component on the resulting dose in order to identify the major component of the uncertainty in a bioassay. The results of this study can be applied to various situations. In cases of severe internal exposure, the causation probability of a deterministic health effect can be derived from the dose distribution, and a high statistical value ( e.g., the 95th percentile of the distribution) can be used to determine the appropriate intervention. The distribution-based sensitivity analysis can also be used to quantify the contribution of each factor to the dose uncertainty, which is essential information for reducing and optimizing the uncertainty in the internal dose assessment. Therefore, the present study can contribute to retrospective dose assessment for accidental internal exposure scenarios, as well as to internal dose monitoring optimization and uncertainty reduction.

  15. Effects of a radiation dose reduction strategy for computed tomography in severely injured trauma patients in the emergency department: an observational study.

    PubMed

    Kim, Soo Hyun; Jung, Seung Eun; Oh, Sang Hoon; Park, Kyu Nam; Youn, Chun Song

    2011-11-03

    Severely injured trauma patients are exposed to clinically significant radiation doses from computed tomography (CT) imaging in the emergency department. Moreover, this radiation exposure is associated with an increased risk of cancer. The purpose of this study was to determine some effects of a radiation dose reduction strategy for CT in severely injured trauma patients in the emergency department. We implemented the radiation dose reduction strategy in May 2009. A prospective observational study design was used to collect data from patients who met the inclusion criteria during this one year study (intervention group) from May 2009 to April 2010. The prospective data were compared with data collected retrospectively for one year prior to the implementation of the radiation dose reduction strategy (control group). By comparison of the cumulative effective dose and the number of CT examinations in the two groups, we evaluated effects of a radiation dose reduction strategy. All the patients met the institutional adult trauma team activation criteria. The radiation doses calculated by the CT scanner were converted to effective doses by multiplication by a conversion coefficient. A total of 118 patients were included in this study. Among them, 33 were admitted before May 2009 (control group), and 85 were admitted after May 2009 (intervention group). There were no significant differences between the two groups regarding baseline characteristics, such as injury severity and mortality. Additionally, there was no difference between the two groups in the mean number of total CT examinations per patient (4.8 vs. 4.5, respectively; p = 0.227). However, the mean effective dose of the total CT examinations per patient significantly decreased from 78.71 mSv to 29.50 mSv (p < 0.001). The radiation dose reduction strategy for CT in severely injured trauma patients effectively decreased the cumulative effective dose of the total CT examinations in the emergency department. But not effectively decreased the number of CT examinations.

  16. Current Status and Future Challenges in Risk-Based Radiation Engineering

    NASA Technical Reports Server (NTRS)

    Pellish, Jonathan A.

    2017-01-01

    This presentation covers the basis and challenges for radiation effects in electronic systems. The three main types of radiation effects in electronics are: 1) total ionizing dose (TID), 2) total non-ionizing dose (TNID) / displacement damage dose (DDD), and 3) single-event effect (SEE). Some content on relevant examples of effects, current concerns, and possible environmental model-driven solutions are also included.

  17. Linac-based total body irradiation (TBI) with volumetric modulated arc therapy (VMAT)

    NASA Astrophysics Data System (ADS)

    Tas, B.; Durmus, I. F.; Okumus, A.; Uzel, O. E.

    2017-02-01

    To evaluate dose distribution of Volumetric modulated arc therapy (VMAT) planning tecnique using Versa HD® lineer accelerator to deliver Total Body Irradiation (TBI) on the coach. Eight TBI patient's Treatment Planning System (TPS) were performed with dual arc VMAT for each patient. The VMAT-TBI consisted of three isocentres and three dual overlapping arcs. The prescribed dose was 12 Gy. Mean dose to lung and kidney were restricted less than 10 Gy and max. dose to lens were restricted less than 6 Gy. The plans were verified using 2D array and ion chamber. The comparison between calculation and measurement were made by γ-index analysis and absolute dose. An average total delivery time was determined 923±34 seconds and an average MU was determined 2614±228 MUs for dual arc VMAT. Mean dose to lungs was 9.7±0.2 Gy, mean dose to kidneys was 8.8±0.3 Gy, max. dose to lens was 5.5±0.3 Gy and max. dose was 14.6±0.3 Gy, HI of PTV was 1.13±0.2, mean dose to PTV was 12.6±1.5 Gy and mean γ-index pass rate was %97.1±1.9. The results show that the tecnique for TBI using VMAT on the treatment coach is feasible.

  18. Epidural analgesia practices for labour: results of a 2005 national survey in Ireland.

    PubMed

    Fanning, Rebecca A; Briggs, Liam P; Carey, Michael F

    2009-03-01

    The last 25 years have seen changes in the management of epidural analgesia for labour, including the advent of low-dose epidural analgesia, the development of new local anaesthetic agents, various regimes for maintaining epidural analgesia and the practice of combined spinal-epidural analgesia. We conducted a survey of Irish obstetric anaesthetists to obtain information regarding the conduct and management of obstetric epidural analgesia in Ireland in 2005. The specific objective of this survey was to discover whether new developments in obstetric anaesthesia have been incorporated into clinical practice. A postal survey was sent to all anaesthetists with a clinical commitment for obstetric anaesthesia in the sites approved for training by the College of Anaesthetists, Ireland. Fifty-three per cent of anaesthetists surveyed responded. The majority of anaesthetists (98%) use low-dose epidural analgesia for the maintenance of analgesia. Only 11% use it for test-dosing and 32% for the induction of analgesia. The combined spinal-epidural analgesia method is used by 49%, but two-thirds of those who use it perform fewer than five per month. Patient-controlled epidural analgesia was in use at only one site. It appears that Irish obstetric anaesthetists have adopted the low-dose epidural analgesia trend for the maintenance of labour analgesia. This practice is not as widespread, however, for test dosing, the induction of analgesia dose or in the administration of intermittent epidural boluses to maintain analgesia when higher concentrations are used. Since its introduction in 2000, levobupivacaine has become the most popular local anaesthetic agent.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farfan, E.; Jannik, T.

    This article describes major studies performed by the Chernobyl Center's International Radioecology Laboratory (Slavutich, Ukraine) on radioecology of murine rodents and shrews inhabiting the Chernobyl Exclusion Zone. The article addresses the long-term (1986-2005) and seasonal dynamics of radioactive contamination of animals, and reviews interspecies differences in radionuclide accumulations and factors affecting the radionuclide accumulations. It is shown that bioavailability of radionuclides in the 'soil-to-plant' chain and a trophic specialization of animals play key roles in determining their actual contamination levels. The total absorbed dose rates in small mammals significantly reduced during the years following the Chernobyl Nuclear Power Plant accident.more » In 1986, the absorbed dose rate reached 1.3-6.0 Gy hr{sup -1} in the central areas of the Chernobyl Exclusion Zone (the 'Red Forest'). In 1988 and 1990, the total absorbed dose rates were 1.3 and 0.42 Gy hr{sup -1}, respectively. In 1995, 2000, and 2005, according to the present study, the total absorbed dose rates rarely exceeded 0.00023, 0.00018, and 0.00015 Gy hr{sup -1}, respectively. Contributions of individual radiation sources into the total absorbed dose are described.« less

  20. Strategies for systemic radiotherapy of micrometastases using antibody-targeted 131I.

    PubMed

    Wheldon, T E; O'Donoghue, J A; Hilditch, T E; Barrett, A

    1988-02-01

    A simple analysis is developed to evaluate the likely effectiveness of treatment of micrometastases by antibody-targeted 131I. Account is taken of the low levels of tumour uptake of antibody-conjugated 131I presently achievable and of the "energy wastage" in targeting microscopic tumours with a radionuclide whose disintegration energy is widely dissipated. The analysis shows that only modest doses can be delivered to micrometastases when total body dose is restricted to levels which allow recovery of bone marrow. Much higher doses could be delivered to micrometastases when bone marrow rescue is used. A rationale is presented for targeted systemic radiotherapy used in combination with external beam total body irradiation (TBI) and bone marrow rescue. This has some practical advantages. The effect of the targeted component is to impose a biological non-uniformity on the total body dose distribution with regions of high tumour cell density receiving higher doses. Where targeting results in high doses to particular normal organs (e.g. liver, kidney) the total dose to these organs could be kept within tolerable limits by appropriate shielding of the external beam radiation component of the treatment. Greater levels of tumour cell kill should be achievable by the combination regime without any increase in normal tissue damage over that inflicted by conventional TBI. The predicted superiority of the combination regime is especially marked for tumours just below the threshold for detectability (e.g. approximately 1 mm-1 cm diameter). This approach has the advantage that targeted radiotherapy provides only a proportion of the total body dose, most of which is given by a familiar technique. The proportion of dose given by the targeted component could be increased as experience is gained. The predicted superiority of the combination strategy should be experimentally testable using laboratory animals. Clinical applications should be cautiously approached, with due regard to the limitations of the theoretical analysis.

  1. The Hematopoietic Syndrome of the Acute Radiation Syndrome in Rhesus Macaques: A Systematic Review of the Lethal Dose Response Relationship.

    PubMed

    MacVittie, Thomas J; Farese, Ann M; Jackson, William

    2015-11-01

    Well characterized animal models that mimic the human response to potentially lethal doses of radiation are required to assess the efficacy of medical countermeasures under the criteria of the U.S. Food and Drug Administration "animal rule." Development of a model requires the determination of the radiation dose response relationship and time course of mortality and morbidity across the hematopoietic acute radiation syndrome. The nonhuman primate, rhesus macaque, is a relevant animal model that may be used to determine the efficacy of medical countermeasures to mitigate major signs of morbidity and mortality at selected lethal doses of total body irradiation. A systematic review of relevant studies that determined the dose response relationship for the hematopoietic acute radiation syndrome in the rhesus macaque relative to radiation quality, dose rate, and exposure uniformity has never been performed. The selection of data cohorts was made from the following sources: Ovid Medline (1957-present), PubMed (1954-present), AGRICOLA (1976-present), Web of Science (1954-present), and U.S. HHS REPORT (2002 to present). The following terms were used: Rhesus, total body-irradiation, total body x irradiation, TBI, irradiation, gamma radiation, hematopoiesis, LD50/60, Macaca mulatta, whole-body irradiation, nonhuman primate, NHP, monkey, primates, hematopoietic radiation syndrome, mortality, and nuclear radiation. The reference lists of all studies, published and unpublished, were reviewed for additional studies. The total number of hits across all search sites was 3,001. There were a number of referenced, unpublished, non-peer reviewed government reports that were unavailable for review. Fifteen studies, 11 primary (n = 863) and four secondary (n = 153) studies [n = 1,016 total nonhuman primates (NHP), rhesus Macaca mulatta] were evaluated to provide an informative and consistent review. The dose response relationships (DRRs) were determined for uniform or non-uniform total body irradiation (TBI) with 250 kVp or 2 MeV x radiation, Co gamma radiation and reactor- and nuclear weapon-derived mixed gamma: neutron-radiation, delivered at various dose rates from a total body, bilateral, rotational, or unilateral exposure aspect. The DRRs established by a probit analysis vs. linear dose relationship were characterized by two main parameters or dependent variables: a slope and LD50/30. Respective LD50/30 values for studies that used 250 kVp x radiation (five primary studies combined, n = 338), 2 MeV x radiation, Co gamma radiation, and steady-state reactor-derived mixed gamma:neutron radiation for total body uniform exposures were 521 rad [498, 542], 671 rad [632, 715], 644 rad [613, 678], and 385 rad [357, 413]. The respective slopes were steep and ranged from 0.738 to 1.316. The DRR, LD50/30 values and slopes were also determined for total body, non-uniform, unilateral, pulse-rate exposures of mixed gamma:neutron radiation derived at reactor and nuclear weapon detonations. The LD50/30 values were, respectively, 395 rad [337, 432] and 412 rad [359, 460]. Secondary data sets of limited studies that did not describe a DRR were used to support the mid-to-high lethal dose range for the H-ARS and the threshold dose range for the concurrent acute GI ARS. The available evidence provided a reliable and extensive database that characterized the DRR for the H-ARS in young rhesus macaques exposed to 250 kVp uniform total body x radiation without the benefit of medical management. A less substantial but consistent database demonstrated the DRR for total body exposure of differing radiation quality, dose rate and non-uniform exposure. The DRR for the H-ARS is characterized by steep slopes and relative LD50/30 values that reflect the radiation quality, exposure aspect, and dose rate over a range in time from 1954-2012.

  2. Compendium of Current Total Ionizing Dose Results and Displacement Damage Results for Candidate Spacecraft Electronics for NASA

    NASA Technical Reports Server (NTRS)

    Cochran, Donna J.; O'Bryan, Martha V.; Buchner, Stephen P.; Poivey, Christian; Ladbury, Ray L.; LaBel, Kenneth A.

    2007-01-01

    Sensitivity of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage is studied. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices.

  3. Simultaneous integrated vs. sequential boost in VMAT radiotherapy of high-grade gliomas.

    PubMed

    Farzin, Mostafa; Molls, Michael; Astner, Sabrina; Rondak, Ina-Christine; Oechsner, Markus

    2015-12-01

    In 20 patients with high-grade gliomas, we compared two methods of planning for volumetric-modulated arc therapy (VMAT): simultaneous integrated boost (SIB) vs. sequential boost (SEB). The investigation focused on the analysis of dose distributions in the target volumes and the organs at risk (OARs). After contouring the target volumes [planning target volumes (PTVs) and boost volumes (BVs)] and OARs, SIB planning and SEB planning were performed. The SEB method consisted of two plans: in the first plan the PTV received 50 Gy in 25 fractions with a 2-Gy dose per fraction. In the second plan the BV received 10 Gy in 5 fractions with a dose per fraction of 2 Gy. The doses of both plans were summed up to show the total doses delivered. In the SIB method the PTV received 54 Gy in 30 fractions with a dose per fraction of 1.8 Gy, while the BV received 60 Gy in the same fraction number but with a dose per fraction of 2 Gy. All of the OARs showed higher doses (Dmax and Dmean) in the SEB method when compared with the SIB technique. The differences between the two methods were statistically significant in almost all of the OARs. Analysing the total doses of the target volumes we found dose distributions with similar homogeneities and comparable total doses. Our analysis shows that the SIB method offers advantages over the SEB method in terms of sparing OARs.

  4. Micron MT29F128G08AJAAA 128GB Asynchronous Flash Memory Total Ionizing Dose Characterization Test Report

    NASA Technical Reports Server (NTRS)

    Campola, Michael; Wyrwas, Edward

    2017-01-01

    The purpose of this test was to characterize the Micron MT29F128G08AJAAAs parameter degradation for total dose response and to evaluate and compare lot date codes for sensitivity. In the test, the device was exposed to both low dose and high dose rate (HDR) irradiations using gamma radiation. Device parameters such as leakage currents, quantity of upset bits and overall chip and die health were investigated to determine which lot is more robust.

  5. Differences in botulinum toxin dosing between patients with adductor spasmodic dysphonia and essential voice tremor.

    PubMed

    Orbelo, Diana M; Duffy, Joseph R; Hughes Borst, Becky J; Ekbom, Dale; Maragos, Nicolas E

    2014-01-01

    To explore possible dose differences in average botulinum toxin (BTX) given to patients with adductor spasmodic dysphonia (ADSD) compared with patients with essential voice tremor (EVT). A retrospective study compared the average BTX dose injected in equal doses to the thyroarytenoid (TA) muscles of 51 patients with ADSD with 52 patients with EVT. Those with ADSD received significantly higher total doses (6.80 ± 2.79 units) compared with those with EVT (5.02 ± 1.65 units). Dose at time of first injection, age at time of first injection, gender, year of first injection, and average time between injections were included in multivariate analysis but did not interact with total average dose findings. Patients with ADSD may need relatively higher doses of BTX injections to bilateral TA muscles compared with patients with EVT. Copyright © 2014 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  6. Estimation of the total effective dose from low-dose CT scans and radiopharmaceutical administrations delivered to patients undergoing SPECT/CT explorations.

    PubMed

    Montes, Carlos; Tamayo, Pilar; Hernandez, Jorge; Gomez-Caminero, Felipe; García, Sofia; Martín, Carlos; Rosero, Angela

    2013-08-01

    Hybrid imaging, such as SPECT/CT, is used in routine clinical practice, allowing coregistered images of the functional and structural information provided by the two imaging modalities. However, this multimodality imaging may mean that patients are exposed to a higher radiation dose than those receiving SPECT alone. The study aimed to determine the radiation exposure of patients who had undergone SPECT/CT examinations and to relate this to the Background Equivalent Radiation Time (BERT). 145 SPECT/CT studies were used to estimate the total effective dose to patients due to both radiopharmaceutical administrations and low-dose CT scans. The CT contribution was estimated by the Dose-Length Product method. Specific conversion coefficients were calculated for SPECT explorations. The radiation dose from low-dose CTs ranged between 0.6 mSv for head and neck CT and 2.6 mSv for whole body CT scan, representing a maximum of 1 year of background radiation exposure. These values represent a decrease of 80-85% with respect to the radiation dose from diagnostic CT. The radiation exposure from radiopharmaceutical administration varied from 2.1 mSv for stress myocardial perfusion SPECT to 26 mSv for gallium SPECT in patients with lymphoma. The BERT ranged from 1 to 11 years. The contribution of low-dose CT scans to the total radiation dose to patients undergoing SPECT/CT examinations is relatively low compared with the effective dose from radiopharmaceutical administration. When a CT scan is only acquired for anatomical localization and attenuation correction, low-dose CT scan is justified on the basis of its lower dose.

  7. Water and tissue equivalence of a new PRESAGE{sup Registered-Sign} formulation for 3D proton beam dosimetry: A Monte Carlo study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gorjiara, Tina; Kuncic, Zdenka; Doran, Simon

    2012-11-15

    Purpose: To evaluate the water and tissue equivalence of a new PRESAGE{sup Registered-Sign} 3D dosimeter for proton therapy. Methods: The GEANT4 software toolkit was used to calculate and compare total dose delivered by a proton beam with mean energy 62 MeV in a PRESAGE{sup Registered-Sign} dosimeter, water, and soft tissue. The dose delivered by primary protons and secondary particles was calculated. Depth-dose profiles and isodose contours of deposited energy were compared for the materials of interest. Results: The proton beam range was found to be Almost-Equal-To 27 mm for PRESAGE{sup Registered-Sign }, 29.9 mm for soft tissue, and 30.5 mmmore » for water. This can be attributed to the lower collisional stopping power of water compared to soft tissue and PRESAGE{sup Registered-Sign }. The difference between total dose delivered in PRESAGE{sup Registered-Sign} and total dose delivered in water or tissue is less than 2% across the entire water/tissue equivalent range of the proton beam. The largest difference between total dose in PRESAGE{sup Registered-Sign} and total dose in water is 1.4%, while for soft tissue it is 1.8%. In both cases, this occurs at the distal end of the beam. Nevertheless, the authors find that PRESAGE{sup Registered-Sign} dosimeter is overall more tissue-equivalent than water-equivalent before the Bragg peak. After the Bragg peak, the differences in the depth doses are found to be due to differences in primary proton energy deposition; PRESAGE{sup Registered-Sign} and soft tissue stop protons more rapidly than water. The dose delivered by secondary electrons in the PRESAGE{sup Registered-Sign} differs by less than 1% from that in soft tissue and water. The contribution of secondary particles to the total dose is less than 4% for electrons and Almost-Equal-To 1% for protons in all the materials of interest. Conclusions: These results demonstrate that the new PRESAGE{sup Registered-Sign} formula may be considered both a tissue- and water-equivalent 3D dosimeter for a 62 MeV proton beam. The results further suggest that tissue-equivalent thickness may provide better dosimetric and geometric accuracy than water-equivalent thickness for 3D dosimetry of this proton beam.« less

  8. Exploring Radiotherapy Targeting Strategy and Dose: A Pooled Analysis of Cooperative Group Trials of Combined Modality Therapy for Stage III Non-Small Cell Lung Cancer.

    PubMed

    Schild, Steven E; Fan, Wen; Stinchcombe, Thomas E; Vokes, Everett E; Ramalingam, Suresh S; Bradley, Jeffrey D; Kelly, Karen; Pang, Herbert H; Wang, Xiaofei

    2018-04-21

    Concurrent chemoradiotherapy(CRT) is standard therapy for locally-advanced non-small-cell lung cancer(LA-NSCLC)patients. This study was performed to examine thoracic radiotherapy(TRT) parameters and their impact on patient survival. We collected Individual patient data(IPD) from 3600LA-NSCLC patients participating in 16 cooperative group trials of concurrent CRT. The primary TRT parameters examined included field design strategy(elective nodal irradiation(ENI) compared to involved field TRT(IF-TRT)), total dose, and biologically effective dose(BED). Hazard ratios(HRs) for overall survival were calculated with univariable and multivariable Cox models. TRT doses ranged from 60 to 74 Gy with most treatments administered once-daily. ENI was associated with poorer survival than IF-TRT(univariable HR,1.37;95%CI,1.24-1.51,p<0.0001;multivariable HR,1.31;95%CI,1.08-1.59,p=0.002). The median survival of the IF and ENI patients were 24 and 16 months, respectively. Patients were divided into 3 dose groups: low total dose(60 Gy), medium total dose(>60Gy-66Gy) and high total dose(>66Gy-74 Gy). With reference to the low dose group, the multivariable HR's were 1.08 for the medium dose group(95%CI=0.93-1.25) and 1.12 for the high dose group(CI=0.97-1.30).The univariate p=0.054 and multivariable p=0.17. BED was grouped as follows: low(<55.5Gy 10 ), medium(=55.5 Gy 10) , or high(>55.5 Gy 10 ). With reference to the low BED group, the HR was 1.00(95%CI=0.85-1.18) for the medium BED group and 1.10(95%CI=0.93-1.31) for the high BED group. The univariable p=0.076 and multivariable p=0.16. For LA-NSCLC patients treated with concurrent CRT, IF-TRT was associated with significantly better survival than ENI-TRT. TRT total and BED dose levels were not significantly associated with patient survival. Future progress will require research focusing on better systemic therapy and TRT. Copyright © 2018. Published by Elsevier Inc.

  9. Total-dose radiation effects data for semiconductor devices, volume 2

    NASA Technical Reports Server (NTRS)

    Price, W. E.; Martin, K. E.; Nichols, D. K.; Gauthier, M. K.; Brown, S. F.

    1981-01-01

    Total ionizing dose radiation test data on integrated circuits are analyzed. Tests were performed with the electron accelerator (Dynamitron) that provides a steady state 2.5 MeV electron beam. Some radiation exposures were made with a Cobalt-60 gamma ray source. The results obtained with the Cobalt-60 source are considered an approximate measure of the radiation damage that would be incurred by an equivalent dose of electrons.

  10. Comparative analysis of dosimetry parameters for nuclear medicine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toohey, R.E.; Stabin, M.G.

    For years many have employed the concept of ``total-body dose`` or ``whole-body dose,`` i.e., the total energy deposited in the body divided by the mass of the body, when evaluating the risks of different nuclear medicine procedures. The effective dose equivalent (H{sub E}), first described in ICRP Publication 26, has been accepted by some as a better quantity to use in evaluating the total risk of a procedure, but its use has been criticized by others primarily because the tissue weighting factors were intended for use in the radiation worker, rather than the nuclear medicine patient population. Nevertheless, in ICRPmore » Publication 52, the ICRP has suggested that the H{sub E} may be used in nuclear medicine. The ICRP also has published a compendium of dose estimates, including H{sub E} values, for various nuclear medicine procedures at various ages in ICRP Publication 53. The effective dose (E) of ICRP Publication 60 is perhaps more suitable for use in nuclear medicine, with tissue weighting factors based on the entire population. Other comparisons of H{sub E} and E have been published. The authors have used the program MIRDOSE 3.1 to compute total-body dose, H{sub E}, and E for 62 radiopharmaceutical procedures, based on the best current biokinetic data available.« less

  11. Relationship between high daily erythemal UV doses, total ozone, surface albedo and cloudiness: An analysis of 30 years of data from Switzerland and Austria

    NASA Astrophysics Data System (ADS)

    Rieder, H. E.; Staehelin, J.; Weihs, P.; Vuilleumier, L.; Maeder, J. A.; Holawe, F.; Blumthaler, M.; Lindfors, A.; Peter, T.; Simic, S.; Spichtinger, P.; Wagner, J. E.; Walker, D.; Ribatet, M.

    2010-10-01

    This work investigates the occurrence frequency of days with high erythemal UV doses at three stations in Switzerland and Austria (Davos, Hoher Sonnblick and Vienna) for the time period 1974-2003. While several earlier studies have reported on increases in erythemal UV dose up to 10% during the last decades, this study focuses on days with high erythemal UV dose, which is defined as a daily dose at least 15% higher than for 1950s clear-sky conditions (which represent preindustrial conditions with respect to anthropogenic chlorine). Furthermore, the influence of low column ozone, clear-sky/partly cloudy conditions and surface albedo on UV irradiance has been analyzed on annual and seasonal basis. The results of this study show that in the Central Alpine Region the number of days with high UV dose increased strongly in the early 1990s. A large fraction of all days with high UV dose occurring in the period 1974-2003 was found especially during the years 1994-2003, namely 40% at Davos, 54% at Hoher Sonnblick and 65% at Vienna. The importance of total ozone, clear-sky/partly cloudy conditions and surface albedo (e.g. in dependence of snow cover) varies strongly among the seasons. However, overall the interplay of low total ozone and clear-sky/partly cloudy conditions led to the largest fraction of days showing high erythemal UV dose. Furthermore, an analysis of the synoptic weather situation showed that days with high erythemal UV dose, low total ozone and high relative sunshine duration occur at all three stations more frequently during situations with low pressure gradients or southerly advection.

  12. Diagnostic radiation exposure in pediatric trauma patients.

    PubMed

    Brunetti, Marissa A; Mahesh, Mahadevappa; Nabaweesi, Rosemary; Locke, Paul; Ziegfeld, Susan; Brown, Robert

    2011-02-01

    The amount of imaging studies performed for disease diagnosis has been rapidly increasing. We examined the amount of radiation exposure that pediatric trauma patients receive because they are an at-risk population. Our hypothesis was that pediatric trauma patients are exposed to high levels of radiation during a single hospital visit. Retrospective review of children who presented to Johns Hopkins Pediatric Trauma Center from July 1, 2004, to June 30, 2005. Radiographic studies were recorded for each patient and doses were calculated to give a total effective dose of radiation. All radiographic studies that each child received during evaluation, including any associated hospital admission, were included. A total of 945 children were evaluated during the study year. A total of 719 children were included in the analysis. Mean age was 7.8 (±4.6) years. Four thousand six hundred three radiographic studies were performed; 1,457 were computed tomography (CT) studies (31.7%). Average radiation dose was 12.8 (±12) mSv. We found that while CT accounted for only 31.7% of the radiologic studies performed, it accounted for 91% of the total radiation dose. Mean dose for admitted children was 17.9 (±13.8) mSv. Mean dose for discharged children was 8.4 (±7.8) mSv (p<0.0001). Burn injuries had the lowest radiation dose [1.2 (±2.6) mSv], whereas motor vehicle collision victims had the highest dose [18.8 (±14.7) mSv]. When the use of radiologic imaging is considered essential, cumulative radiation exposure can be high. In young children with relatively long life spans, the benefit of each imaging study and the cumulative radiation dose should be weighed against the long-term risks of increased exposure.

  13. Radiation optic neuropathy after megavoltage external-beam irradiation: Analysis of time-dose factors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parsons, J.T.; Bova, F.J.; Million, R.R.

    1994-11-15

    To investigate the risk of radiation-induced optic neuropathy according to total radiotherapy dose and fraction size, based on both retrospective and prospectively collected data. Between October 1964 and May 1989, 215 optic nerves in 131 patients received fractionated external-beam irradiation during the treatment of primary extracranial head and neck tumors. All patients had a minimum of 3 years of ophthalmologic follow-up (range, 3 to 21 years). The clinical end point was visual acuity of 20/100 or worse as a result of optic nerve injury. Anterior ischemic optic neuropathy developed in five nerves (at mean and median times of 32 andmore » 30 months, respectively, and a range of 2-4 years). Retrobulbar optic neuropathy developed in 12 nerves (at mean and median times of 47 and 28 months, respectively, and a range of 1-14 years). No injuries were observed in 106 optic nerves that received a total dose of <59 Gy. Among nerves that received doses of {ge} 60 Gy, the dose per fraction was more important than the total dose in producing optic neuropathy. The 15-year actuarial risk of optic compared with 47% when given in fraction sizes {ge}1.9 Gy. The data also suggest an increased risk of optic nerve injury with increasing age. As there is no effective treatment of radiation-induced optic neuropathy, efforts should be directed at its prevention by minimizing the total dose, paying attention to the dose per fraction to the nerve, and using reduced field techniques where appropriate to limit the volume of tissues that receive high-dose irradiation. 32 refs., 5 figs., 5 tabs.« less

  14. Mold and aflatoxin reduction by gamma radiation of packed hot peppers and their evolution during storage.

    PubMed

    Iqbal, Qumer; Amjad, Muhammad; Asi, Muhammad Rafique; Ariño, Agustin

    2012-08-01

    The effect of gamma radiation on moisture content, total mold counts, Aspergillus counts, and aflatoxins of three hot pepper hybrids (Sky Red, Maha, and Wonder King) was investigated. Whole dried peppers packed in polyethylene bags were gamma irradiated at 0 (control), 2, 4, and 6 kGy and stored at 25°C for 90 days. Gamma radiation proved to be effective in reducing total mold and Aspergillus counts in a dose-dependent relationship. Total mold counts in irradiated peppers immediately after treatments were significantly lowered compared with those in nonirradiated samples, achieving 90 and 99% reduction at 2- and 4-kGy doses, respectively. Aspergillus counts were significantly reduced, by 93 and 97%, immediately after irradiation at doses of 2 and 4 kGy, respectively. A radiation dose of 6 kGy completely eliminated the population of total molds and Aspergillus fungi. The evolution of total molds in control and irradiated samples indicated no further fungal proliferation during 3 months of storage at 25°C. Aflatoxin levels were slightly affected by radiation doses of 2 and 4 kGy and showed a nonsignificant reduction of 6% at the highest radiation dose of 6 kGy. The distinct effectiveness of gamma radiation in molds and aflatoxins can be explained by the target theory of food irradiation, which states that the likelihood of a microorganism or a molecule being inactivated by gamma rays increases as its size increases.

  15. Rumen modulatory effect of thyme, clove and peppermint oils in vitro using buffalo rumen liquor.

    PubMed

    Roy, Debashis; Tomar, S K; Kumar, Vinod

    2015-02-01

    The present study was conducted to examine the rumen modulatory effect of thyme, clove and peppermint oils on rumen fermentation pattern in vitro using roughage based diet. Thyme, clove and peppermint oils were tested at concentration of 0, 30, 300 and 600 mg/l (ppm) of total culture fluid using in vitro gas production technique in wheat straw based diet (concentrate: Wheat straw 50:50). Different in vitro parameters e.g., total gas production, methane production, nutrient degradability, volatile fatty acid (VFA) production and ammonia nitrogen concentration were studied using buffalo rumen liquor. Thyme oil at higher dose level (600 ppm) reduced (p<0.05) total gas production, feed degradability and ammonia nitrogen (NH3-N) concentration whereas total VFA concentration was significantly lower (p>0.05) in 300 and 600 ppm dose levels. 600 ppm dose level of clove oil reduced (p<0.05) total gas production, feed degradability, total VFA and acetate to propionate ratio. Methane production was significantly reduced (p<0.05) in 300 and 600 ppm dose levels of clove and peppermint oil. Right combination of these essential oils may prove to enhance performance of animals by reducing methane production and inhibiting protein degradation in rumen.

  16. SU-E-T-812: Volumetric Modulated Arc Therapy-Total Body Irradiation (VMAT-TBI) V.s. Conventional Extended SSD-TBI (cTBI): A Dosimetric Comparisom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ouyang, L; Folkerts, M; Lee, H

    2015-06-15

    Purpose: To perform a dosimetric evaluation on a new developed volumetric modulated arc therapy based total body irradiation (VMAT-TBI). Methods: Three patients were CT scanned with an indexed rotatable body frame to get whole body CT images. Concatenated CT images were imported in Pinnacle treatment planning system and whole body and lung were contoured as PTV and organ at risk, respectively. Treatment plans were generated by matching multiple isocenter volumetric modulated arc (VMAT) fields of the upper body and multiple isocenter parallel-opposed fields of the lower body. For each plan, 1200 cGy in 8 fractions was prescribed to the wholemore » body volume and the lung dose was constrained to a mean dose of 750 cGy. Such a two-level dose plan was achieved by inverse planning of the torso VMAT fields. For comparison, conventional standing TBI (cTBI) plans were generated on the same whole body CT images at an extended SSD (550cm).The shape of compensators and lung blocks are simulated using body segments and lung contours Compensation was calculated based on the patient CT images, in mimic of the standing TBI treatment. The whole body dose distribution of cTBI plans were calculated with a home-developed GPU Monte Carlo dose engine. Calculated cTBI dose distribution was prescribed to the mid-body point at umbilical level. Results: The VMAT-TBI treatment plans of three patients’ plans achieved 80.2%±5.0% coverage of the total body volume within ±10% of the prescription dose, while cTBI treatment plans achieved 72.2%±4.0% coverage of the total body volume. The averaged mean lung dose of all three patients is lower for VMAT-TBI (7.48 cGy) than for cTBI (8.96 cGy). Conclusion: The proposed patient comfort-oriented VMAT-TBI technique provides for a uniform dose distribution within the total body while reducing the dose to the lungs.« less

  17. A bounding estimate of neutron dose based on measured photon dose around single pass reactors at the Hanford site.

    PubMed

    Taulbee, Timothy D; Glover, Samuel E; Macievic, Gregory V; Hunacek, Mickey; Smith, Cheryl; DeBord, Gary W; Morris, Donald; Fix, Jack

    2010-07-01

    Neutron and photon radiation survey records have been used to evaluate and develop a neutron to photon (NP) ratio to reconstruct neutron doses to workers around Hanford's single pass reactors that operated from 1945 to 1972. A total of 5,773 paired neutron and photon measurements extracted from 57 boxes of survey records were used in the development of the NP ratio. The development of the NP ratio enables the use of the recorded dose from an individual's photon dosimeter badge to be used to estimate the unmonitored neutron dose. The Pearson rank correlation between the neutron and photon measurements was 0.71. The NP ratio best fit a lognormal distribution with a geometric mean (GM) of 0.8, a geometric standard deviation (GSD) of 2.95, and the upper 95 th % of this distribution was 4.75. An estimate of the neutron dose based on this NP ratio is considered bounding due to evidence that up to 70% of the total photon exposure received by workers around the single pass reactors occurs during shutdown maintenance and refueling activities when there is no significant neutron exposure. Thus when this NP ratio is applied to the total measured photon dose from an individual film badge dosimeter, the resulting neutron dose is considered bounded.

  18. Internal dosimetry of inhaled iodine-131.

    PubMed

    Kiani Nasab, Mitra; Rafat Motavalli, Laleh; Miri Hakimabad, Hashem

    2018-01-01

    In this paper, the dose assessment for the iodine inhalation exposure in 19 aerosol sizes and three gas/vapor forms at three levels of thyroid uptake, was performed. Two different modes of work (light vs. heavy) and breathing (nose vs. mouth) for aerosol inhalation were investigated. In order to calculate the cumulated activities per unit of inhaled activity, a combined model which included the latest models of both human respiratory and alimentary tract was developed. The S values for 131 I were computed based on the ICRP adult male and female reference voxel phantoms by the Monte Carlo method. Then, the committed equivalent and committed effective dose coefficients were obtained (The data are available at http://www.um.ac.ir/∼mirihakim). In general, for the nonzero thyroid uptakes, the maximum cumulated activity was found in the thyroid. When the thyroid is blocked, however, the maximum depends on the work and breathing mode and radioisotope form. Overall, the maximum CED coefficient was evaluated for the inhalation of elemental iodine at thyroid uptake of ∼27% (2.8 × 10 -8 Sv/Bq). As for the particle inhalation per se, mouth breathing of 0.6 nm and 0.2 μm AMTD particles showed to have the maximum (2.8 × 10 -8 Sv/Bq) and minimum (6.4 × 10 -9 Sv/Bq) CED coefficients, respectively. Compared to the reference CED coefficients, the authors found an increase of about 58% for inhalation of the aerosols with AMAD of 1 μm and 70% for 5 μm. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Estimated fluoride doses from toothpastes should be based on total soluble fluoride.

    PubMed

    Oliveira, Maria José L; Martins, Carolina C; Paiva, Saul M; Tenuta, Livia M A; Cury, Jaime A

    2013-11-01

    The fluoride dose ingested by young children may be overestimated if based on levels of total fluoride (TF) rather than levels of bioavailable fluoride (total soluble fluoride-TSF) in toothpaste. The aim of the present study was to compare doses of fluoride intake based on TF and TSF. Fluoride intake in 158 Brazilian children aged three and four years was determined after tooth brushing with their usual toothpaste (either family toothpaste (n = 80) or children's toothpaste (n = 78)). The estimated dose (mg F/day/Kg of body weight) of TF or TSF ingested was calculated from the chemical analysis of the toothpastes. Although the ingested dose of TF from the family toothpastes was higher than that from the children's toothpastes (0.074 ± 0.007 and 0.039 ± 0.003 mg F/day/Kg, respectively; p < 0.05), no difference between types of toothpaste was found regarding the ingested dose based on TSF (0.039 ± 0.005 and 0.039 ± 0.005 mg F/day/Kg, respectively; p > 0.05). The fluoride dose ingested by children from toothpastes may be overestimated if based on the TF of the product. This finding suggests that the ingested dose should be calculated based on TSF. Dose of TSF ingested by children is similar whether family or children's toothpaste is used.

  20. Estimated Fluoride Doses from Toothpastes Should be Based on Total Soluble Fluoride

    PubMed Central

    Oliveira, Maria José L.; Martins, Carolina C.; Paiva, Saul M.; Tenuta, Livia M. A.; Cury, Jaime A.

    2013-01-01

    The fluoride dose ingested by young children may be overestimated if based on levels of total fluoride (TF) rather than levels of bioavailable fluoride (total soluble fluoride—TSF) in toothpaste. The aim of the present study was to compare doses of fluoride intake based on TF and TSF. Fluoride intake in 158 Brazilian children aged three and four years was determined after tooth brushing with their usual toothpaste (either family toothpaste (n = 80) or children’s toothpaste (n = 78)). The estimated dose (mg F/day/Kg of body weight) of TF or TSF ingested was calculated from the chemical analysis of the toothpastes. Although the ingested dose of TF from the family toothpastes was higher than that from the children’s toothpastes (0.074 ± 0.007 and 0.039 ± 0.003 mg F/day/Kg, respectively; p < 0.05), no difference between types of toothpaste was found regarding the ingested dose based on TSF (0.039 ± 0.005 and 0.039 ± 0.005 mg F/day/Kg, respectively; p > 0.05). The fluoride dose ingested by children from toothpastes may be overestimated if based on the TF of the product. This finding suggests that the ingested dose should be calculated based on TSF. Dose of TSF ingested by children is similar whether family or children’s toothpaste is used. PMID:24189183

Top