... Total hip replacement; Hip hemiarthroplasty; Arthritis - hip replacement; Osteoarthritis - hip replacement ... total hip replacement surgery in patients with hip osteoarthritis: a long-term follow-up of a randomised ...
Kendal, Adrian R; Prieto-Alhambra, Daniel; Arden, Nigel K; Judge, Andrew
2013-01-01
Objectives To compare 10 year mortality rates among patients undergoing metal-on-metal hip resurfacing and total hip replacement in England. Design Retrospective cohort study. Setting English hospital episode statistics database linked to mortality records from the Office for National Statistics. Population All adults who underwent primary elective hip replacement for osteoarthritis from April 1999 to March 2012. The exposure of interest was prosthesis type: cemented total hip replacement, uncemented total hip replacement, and metal-on-metal hip resurfacing. Confounding variables included age, sex, Charlson comorbidity index, rurality, area deprivation, surgical volume, and year of operation. Main outcome measures All cause mortality. Propensity score matching was used to minimise confounding by indication. Kaplan-Meier plots estimated the probability of survival up to 10 years after surgery. Multilevel Cox regression modelling, stratified on matched sets, described the association between prosthesis type and time to death, accounting for variation across hospital trusts. Results 7437 patients undergoing metal-on-metal hip resurfacing were matched to 22 311 undergoing cemented total hip replacement; 8101 patients undergoing metal-on-metal hip resurfacing were matched to 24 303 undergoing uncemented total hip replacement. 10 year rates of cumulative mortality were 271 (3.6%) for metal-on-metal hip resurfacing versus 1363 (6.1%) for cemented total hip replacement, and 239 (3.0%) for metal-on-metal hip resurfacing versus 999 (4.1%) for uncemented total hip replacement. Patients undergoing metal-on-metal hip resurfacing had an increased survival probability (hazard ratio 0.51 (95% confidence interval 0.45 to 0.59) for cemented hip replacement; 0.55 (0.47 to 0.65) for uncemented hip replacement). There was no evidence for an interaction with age or sex. Conclusions Patients with hip osteoarthritis undergoing metal-on-metal hip resurfacing have reduced mortality in the long term compared with those undergoing cemented or uncemented total hip replacement. This difference persisted after extensive adjustment for confounding factors available in our data. The study results can be applied to matched populations, which exclude patients who are very old and have had complex total hip replacements. Although residual confounding is possible, the observed effect size is large. These findings require validation in external cohorts and randomised clinical trials. PMID:24284336
Li, Junyan; Redmond, Anthony C; Jin, Zhongmin; Fisher, John; Stone, Martin H; Stewart, Todd D
2014-08-01
Preclinical durability testing of hip replacement implants is standardised by ISO-14242-1 (2002) which is based on historical inverse dynamics analysis using data obtained from a small sample of normal healthy individuals. It has not been established whether loading cycles derived from normal healthy individuals are representative of loading cycles occurring in patients following total hip replacement. Hip joint kinematics and hip contact forces derived from multibody modelling of forces during normal walking were obtained for 15 asymptomatic total hip replacement patients and compared to 38 normal healthy individuals and to the ISO standard for pre-clinical testing. Hip kinematics in the total hip replacement patients were comparable to the ISO data and the hip contact force in the normal healthy group was also comparable to the ISO cycles. Hip contact forces derived from the asymptomatic total hip replacement patients were comparable for the first part of the stance period but exhibited 30% lower peak loads at toe-off. Although the ISO standard provides a representative kinematic cycle, the findings call into question whether the hip joint contact forces in the ISO standard are representative of those occurring in the joint following total hip replacement. Copyright © 2014. Published by Elsevier Ltd.
Prevalence of Total Hip and Knee Replacement in the United States.
Maradit Kremers, Hilal; Larson, Dirk R; Crowson, Cynthia S; Kremers, Walter K; Washington, Raynard E; Steiner, Claudia A; Jiranek, William A; Berry, Daniel J
2015-09-02
Descriptive epidemiology of total joint replacement procedures is limited to annual procedure volumes (incidence). The prevalence of the growing number of individuals living with a total hip or total knee replacement is currently unknown. Our objective was to estimate the prevalence of total hip and total knee replacement in the United States. Prevalence was estimated using the counting method by combining historical incidence data from the National Hospital Discharge Survey and the Healthcare Cost and Utilization Project (HCUP) State Inpatient Databases from 1969 to 2010 with general population census and mortality counts. We accounted for relative differences in mortality rates between those who have had total hip or knee replacement and the general population. The 2010 prevalence of total hip and total knee replacement in the total U.S. population was 0.83% and 1.52%, respectively. Prevalence was higher among women than among men and increased with age, reaching 5.26% for total hip replacement and 10.38% for total knee replacement at eighty years. These estimates corresponded to 2.5 million individuals (1.4 million women and 1.1 million men) with total hip replacement and 4.7 million individuals (3.0 million women and 1.7 million men) with total knee replacement in 2010. Secular trends indicated a substantial rise in prevalence over time and a shift to younger ages. Around 7 million Americans are living with a hip or knee replacement, and consequently, in most cases, are mobile, despite advanced arthritis. These numbers underscore the substantial public health impact of total hip and knee arthroplasties. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.
Survey of patient-oriented total hip replacement information on the World Wide Web.
Mabrey, J D
2000-12-01
The author conducted an informal survey of materials relating to diseases of the hip and total hip replacement as they appeared on the World Wide Web. The results varied depending on the key words used: hip and replacement yielded 1,818 matches; total hip replacement yielded 1,740 matches; hip replacement yielded 4,565 sites; and hip surgery yielded 1,073 sites. The number of sites for total hip replacement was observed to increase with time, having found an additional 30 sites from an identical search performed only 6 weeks earlier. The nature and quality of these sites varied from well-organized and informative, to personal testaments, to obvious commercial endeavors. Overall, this survey found an abundance of material regarding the hip and hip replacements on the World Wide Web, but orthopaedic societies need to take a more active role in constructing, maintaining, and monitoring these sites to best serve the needs of their patients and their members.
Li, Junyan; McWilliams, Anthony B; Jin, Zhongmin; Fisher, John; Stone, Martin H; Redmond, Anthony C; Stewart, Todd D
2015-06-01
Symptomatic leg length inequality accounts for 8.7% of total hip replacement related claims made against the UK National Health Service Litigation authority. It has not been established whether symptomatic leg length inequality patients following total hip replacement have abnormal hip kinetics during gait. Hip kinetics in 15 unilateral total hip replacement patients with symptomatic leg length inequality during gait was determined through multibody dynamics and compared to 15 native hip healthy controls and 15 'successful' asymptomatic unilateral total hip replacement patients. More significant differences from normal were found in symptomatic leg length inequality patients than in asymptomatic total hip replacement patients. The leg length inequality patients had altered functions defined by lower gait velocity, reduced stride length, reduced ground reaction force, decreased hip range of motion, reduced hip moment and less dynamic hip force with a 24% lower heel-strike peak, 66% higher mid-stance trough and 37% lower toe-off peak. Greater asymmetry in hip contact force was also observed in leg length inequality patients. These gait adaptions may affect the function of the implant and other healthy joints in symptomatic leg length inequality patients. This study provides important information for the musculoskeletal function and rehabilitation of symptomatic leg length inequality patients. Copyright © 2015. Published by Elsevier Ltd.
Primary total hip replacement for displaced subcapital fractures of the femur.
Taine, W H; Armour, P C
1985-03-01
The management of displaced subcapital fracture of the hip is still controversial because of the high incidence of complications after internal fixation or hemiarthroplasty. To avoid some of these complications we have used primary total hip replacement for independently mobile patients over 65 years of age. A total of 163 cases, operated on over four years, have been reviewed. There were relatively more dislocations after operation for fracture than after total replacement for arthritis, and these were associated with a posterior approach to the hip. Only seven revision operations have been required. Of 57 patients who were interviewed an average of 42 months after replacement, 62% had excellent or good results as assessed by the Harris hip score. All the others had major systemic disease which affected their assessment. This inadequacy of current systems of hip assessment is discussed. It is concluded that total hip replacement is the best management for a selected group of patients with this injury, and that further prospective studies are indicated.
The operation of the century: total hip replacement.
Learmonth, Ian D; Young, Claire; Rorabeck, Cecil
2007-10-27
In the 1960s, total hip replacement revolutionised management of elderly patients crippled with arthritis, with very good long-term results. Today, young patients present for hip-replacement surgery hoping to restore their quality of life, which typically includes physically demanding activities. Advances in bioengineering technology have driven development of hip prostheses. Both cemented and uncemented hips can provide durable fixation. Better materials and design have allowed use of large-bore bearings, which provide an increased range of motion with enhanced stability and very low wear. Minimally invasive surgery limits soft-tissue damage and facilitates accelerated discharge and rehabilitation. Short-term objectives must not compromise long-term performance. Computer-assisted surgery will contribute to reproducible and accurate placement of implants. Universal economic constraints in healthcare services dictate that further developments in total hip replacement will be governed by their cost-effectiveness.
Hua, Xijin; Wang, Ling; Al-Hajjar, Mazen; Jin, Zhongmin; Wilcox, Ruth K; Fisher, John
2014-07-01
Finite element models are becoming increasingly useful tools to conduct parametric analysis, design optimisation and pre-clinical testing for hip joint replacements. However, the verification of the finite element model is critically important. The purposes of this study were to develop a three-dimensional anatomic finite element model for a modular metal-on-polyethylene total hip replacement for predicting its contact mechanics and to conduct experimental validation for a simple finite element model which was simplified from the anatomic finite element model. An anatomic modular metal-on-polyethylene total hip replacement model (anatomic model) was first developed and then simplified with reasonable accuracy to a simple modular total hip replacement model (simplified model) for validation. The contact areas on the articulating surface of three polyethylene liners of modular metal-on-polyethylene total hip replacement bearings with different clearances were measured experimentally in the Leeds ProSim hip joint simulator under a series of loading conditions and different cup inclination angles. The contact areas predicted from the simplified model were then compared with that measured experimentally under the same conditions. The results showed that the simplification made for the anatomic model did not change the predictions of contact mechanics of the modular metal-on-polyethylene total hip replacement substantially (less than 12% for contact stresses and contact areas). Good agreements of contact areas between the finite element predictions from the simplified model and experimental measurements were obtained, with maximum difference of 14% across all conditions considered. This indicated that the simplification and assumptions made in the anatomic model were reasonable and the finite element predictions from the simplified model were valid. © IMechE 2014.
[Local infiltration analgesia in total joint replacement].
de Jonge, Tamás; Görgényi, Szabolcs; Szabó, Gabriella; Torkos, Miklós Bulcsú
2017-03-01
Total hip and knee replacment surgeries are characterized by severe postoperative pain. Local infiltration analgesia is proved to be very effective. However this method has not been widely used in Hungary. To evaluate the efficacy of the local infiltration analgesia with modified components in patients underwent total hip or knee replacement surgery. Data of 99 consecutive patients underwent primary total hip or knee replacement surgery were evaluated prospectively. In all the 99 surgeries modified local infiltration analgesia was applied. Postoperative pain reported on a visual analog scale was recorded as well as the need for further analgetics during the first 18 hours after surgery. The cost of the analgetic drugs was calculated. The control group comprised 97 consecutive patients underwent total hip or knee replacement, where local infiltration analgesia was not applied. Statistical analysis was done. Patients received local infiltration analgesia reported significantly less pain (p<0.001). The need for postoperatively given analgetics was almost 50% less, and the cost of all postoperative analgetics was 47% less than in the control group. In total hip and knee replacement surgeries the modified local infiltration analgesia decreases postoperative pain effectively and contribute to the early mobilization of the patients. Orv. Hetil., 2017, 158(9), 352-357.
Bayliss, Lee E; Culliford, David; Monk, A Paul; Glyn-Jones, Sion; Prieto-Alhambra, Daniel; Judge, Andrew; Cooper, Cyrus; Carr, Andrew J; Arden, Nigel K; Beard, David J; Price, Andrew J
2017-04-08
Total joint replacements for end-stage osteoarthritis of the hip and knee are cost-effective and demonstrate significant clinical improvement. However, robust population based lifetime-risk data for implant revision are not available to aid patient decision making, which is a particular problem in young patient groups deciding on best-timing for surgery. We did implant survival analysis on all patients within the Clinical Practice Research Datalink who had undergone total hip replacement or total knee replacement. These data were adjusted for all-cause mortality with data from the Office for National Statistics and used to generate lifetime risks of revision surgery based on increasing age at the time of primary surgery. We identified 63 158 patients who had undergone total hip replacement and 54 276 who had total knee replacement between Jan 1, 1991, and Aug 10, 2011, and followed up these patients to a maximum of 20 years. For total hip replacement, 10-year implant survival rate was 95·6% (95% CI 95·3-95·9) and 20-year rate was 85·0% (83·2-86·6). For total knee replacement, 10-year implant survival rate was 96·1% (95·8-96·4), and 20-year implant survival rate was 89·7% (87·5-91·5). The lifetime risk of requiring revision surgery in patients who had total hip replacement or total knee replacement over the age of 70 years was about 5% with no difference between sexes. For those who had surgery younger than 70 years, however, the lifetime risk of revision increased for younger patients, up to 35% (95% CI 30·9-39·1) for men in their early 50s, with large differences seen between male and female patients (15% lower for women in same age group). The median time to revision for patients who had surgery younger than age 60 was 4·4 years. Our study used novel methodology to investigate and offer new insight into the importance of young age and risk of revision after total hip or knee replacement. Our evidence challenges the increasing trend for more total hip replacements and total knee replacements to be done in the younger patient group, and these data should be offered to patients as part of the shared decision making process. Oxford Musculoskeletal Biomedical Research Unit, National Institute for Health Research. Copyright © 2017 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY license. Published by Elsevier Ltd.. All rights reserved.
Palsis, John A; Brehmer, Thomas S; Pellegrini, Vincent D; Drew, Jacob M; Sachs, Barton L
2018-02-21
In an era of mandatory bundled payments for total joint replacement, accurate analysis of the cost of procedures is essential for orthopaedic surgeons and their institutions to maintain viable practices. The purpose of this study was to compare traditional accounting and time-driven activity-based costing (TDABC) methods for estimating the total costs of total hip and knee arthroplasty care cycles. We calculated the overall costs of elective primary total hip and total knee replacement care cycles at our academic medical center using traditional and TDABC accounting methods. We compared the methods with respect to the overall costs of hip and knee replacement and the costs for each major cost category. The traditional accounting method resulted in higher cost estimates. The total cost per hip replacement was $22,076 (2014 USD) using traditional accounting and was $12,957 using TDABC. The total cost per knee replacement was $29,488 using traditional accounting and was $16,981 using TDABC. With respect to cost categories, estimates using traditional accounting were greater for hip and knee replacement, respectively, by $3,432 and $5,486 for personnel, by $3,398 and $3,664 for space and equipment, and by $2,289 and $3,357 for indirect costs. Implants and consumables were derived from the actual hospital purchase price; accordingly, both methods produced equivalent results. Substantial cost differences exist between accounting methods. The focus of TDABC only on resources used directly by the patient contrasts with the allocation of all operating costs, including all indirect costs and unused capacity, with traditional accounting. We expect that the true costs of hip and knee replacement care cycles are likely somewhere between estimates derived from traditional accounting methods and TDABC. TDABC offers patient-level granular cost information that better serves in the redesign of care pathways and may lead to more strategic resource-allocation decisions to optimize actual operating margins.
Compatibility of the totally replaced hip. Reduction of wear by amorphous diamond coating.
Santavirta, Seppo
2003-12-01
Particulate wear debris in totally replaced hips causes adverse local host reactions. The extreme form of such a reaction, aggressive granulomatosis, was found to be a distinct condition and different from simple aseptic loosening. Reactive and adaptive tissues around the totally replaced hip were made of proliferation of local fibroblast like cells and activated macrophages. Methylmethacrylate and high-molecular-weight polyethylene were shown to be essentially immunologically inert implant materials, but in small particulate form functioned as cellular irritants initiating local biological reactions leading to loosening of the implants. Chromium-cobalt-molybdenum is the most popular metallic implant material; it is hard and tough, and the bearings of this metal are partially self-polishing. In total hip implants, prerequisites for longevity of the replaced hip are good biocompatibility of the materials and sufficient tribological properties of the bearings. The third key issue is that the bearing must minimize frictional shear at the prosthetic bone-implant interface to be compatible with long-term survival. Some of the approaches to meet these demands are alumina-on-alumina and metal-on-metal designs, as well as the use of highly crosslinked polyethylene for the acetabular component. In order to avoid the wear-based deleterious properties of the conventional total hip prosthesis materials or coatings, the present work included biological and tribological testing of amorphous diamond. Previous experiments had demonstrated that a high adhesion of tetrahedral amorphous carbon coatings to a substrate can be achieved by using mixing layers or interlayers. Amorphous diamond was found to be biologically inert, and simulator testing indicated excellent wear properties for conventional total hip prostheses, in which either the ball or both bearing surfaces were coated with hydrogen-free tetrahedral amorphous diamond films. Simulator testing with such total hip prostheses showed no measurable wear or detectable delamination after 15,000,000 test cycles corresponding to 15 years of clinical use. The present work clearly shows that wear is one of the basic problems with totally replaced hips. Diamond coating of the bearing surfaces appears to be an attractive solution to improve longevity of the totally replaced hip.
Ritter, M A; HamiltonCW
1975-01-01
Warfarin, low-dose heparin, or a combination of low-dose heparin and hydrocortisone was administered to 300 patients undergoing total hip replacement. The lowest incidence of thromboembolic (5 per cent) was attained with Warfarin. Further investigation into the method of administration of low-dose heparin is necessary before it can be used effectively as thromboembolism prophylaxis in total hip replacement patients. The addition of hydrocortisone was not found useful. PMID:1138642
Reliability and concurrent validity of the Dutch hip and knee replacement expectations surveys
2010-01-01
Background Preoperative expectations of outcome of total hip and knee arthroplasty are important determinants of patients' satisfaction and functional outcome. Aims of the study were (1) to translate the Hospital for Special Surgery Hip Replacement Expectations Survey and Knee Replacement Expectations Survey into Dutch and (2) to study test-retest reliability and concurrent validity. Methods Patients scheduled for total hip (N = 112) or knee replacement (N = 101) were sent the Dutch Expectations Surveys twice with a 2 week interval to determine test-retest reliability. To determine concurrent validity, the Expectation WOMAC was sent. Results The results for the Dutch Hip Replacement Expectations Survey revealed good test-retest reliability (ICC 0.87), no bias and good internal consistency (alpha 0.86) (N = 72). The correlation between the Hip Expectations Score and the Expectation WOMAC score was 0.59 (N = 86). The results for the Dutch Knee Replacement Expectations Survey revealed good test-retest reliability (ICC 0.79), no bias and good internal consistency (alpha 0.91) (N = 46). The correlation with the Expectation WOMAC score was 0.52 (N = 57). Conclusions Both Dutch Expectations Surveys are reliable instruments to determine patients' expectations before total hip or knee arthroplasty. As for concurrent validity, the correlation between both surveys and the Expectation WOMAC was moderate confirming that the same construct was determined. However, patients scored systematically lower on the Expectation WOMAC compared to the Dutch Expectation Surveys. Research on patients' expectations before total hip and knee replacement has only been performed in a limited amount of countries. With the Dutch Expectations Surveys it is now possible to determine patients' expectations in another culture and healthcare setting. PMID:20958990
Reliability and concurrent validity of the Dutch hip and knee replacement expectations surveys.
van den Akker-Scheek, Inge; van Raay, Jos J A M; Reininga, Inge H F; Bulstra, Sjoerd K; Zijlstra, Wiebren; Stevens, Martin
2010-10-19
Preoperative expectations of outcome of total hip and knee arthroplasty are important determinants of patients' satisfaction and functional outcome. Aims of the study were (1) to translate the Hospital for Special Surgery Hip Replacement Expectations Survey and Knee Replacement Expectations Survey into Dutch and (2) to study test-retest reliability and concurrent validity. Patients scheduled for total hip (N = 112) or knee replacement (N = 101) were sent the Dutch Expectations Surveys twice with a 2 week interval to determine test-retest reliability. To determine concurrent validity, the Expectation WOMAC was sent. The results for the Dutch Hip Replacement Expectations Survey revealed good test-retest reliability (ICC 0.87), no bias and good internal consistency (alpha 0.86) (N = 72). The correlation between the Hip Expectations Score and the Expectation WOMAC score was 0.59 (N = 86). The results for the Dutch Knee Replacement Expectations Survey revealed good test-retest reliability (ICC 0.79), no bias and good internal consistency (alpha 0.91) (N = 46). The correlation with the Expectation WOMAC score was 0.52 (N = 57). Both Dutch Expectations Surveys are reliable instruments to determine patients' expectations before total hip or knee arthroplasty. As for concurrent validity, the correlation between both surveys and the Expectation WOMAC was moderate confirming that the same construct was determined. However, patients scored systematically lower on the Expectation WOMAC compared to the Dutch Expectation Surveys. Research on patients' expectations before total hip and knee replacement has only been performed in a limited amount of countries. With the Dutch Expectations Surveys it is now possible to determine patients' expectations in another culture and healthcare setting.
[Progress assessment of rehabilitation in patients after hip replacement. Preliminary report].
Labecka, Monika; Pingot, Mariusz; Pingot, Julia; Woldańiska-Okońska, Marta
2014-01-01
Coxarthrosis is one of the most common diseases of the motor system. We distinguish primary and secondary coxarthrosis. The premises for total hip replacement include pain, damage to the surface of the acetabulum and the head of the hip, relative shortening of the limb, gluteal, femur and crus muscle atrophy and gait dysfunctions. The aim of this paper is to present the influence of rehabilitation on the improvement of physical ability, especially in respect to quality of gait and antianalgesic efficacy of the physical therapy in patients after total hip replacement. The study was carried out in 37 patients aged 35-72 (mean of age--53.78 +/- 9.92). The group consisted'of 21 women and 16 men. After the total hip replacement, all the patients underwent physical therapy which involved application of laser radiation on the postoperative scar, whirpool and classic massage of the operated limb, exercises in non-weight bearing and weight-bearing exercises and gait reeducation. Modified Laitinen Pain Indicator Questionnaire, Visual Analogue Scale-VAS and the standardized mobility test--Timed-Up-And-Go test were used in the study. The statistical analysis was carried out with the use of the STATYSTIKA 5 PL computer program. The results reached point to the analgesic efficacy of the physical therapy and a better gait quality. Multifactor physical therapy after total hip replacement shows analgesic action. Appropriate selection of exercises and physical treatment have positive influence on gait reeducation in patients after total hip replacement. The Timed Up and Go test may be used in functional assessment of gait in patients with musculoskeletal disorders.
Yoon, Byung-Ho; Lee, Kyung-Hag; Noh, Serae; Ha, Yong-Chan; Lee, Young-Kyun; Koo, Kyung-Hoi
2013-12-01
Concerns of patients on sexual activity after total hip arthroplasty have not been well studied in Asian patients. This study aimed to determine the following: (1) what are the concerns of patients related to sexual activity after total hip arthroplasty? (2) what are the changes in sexual activity after total hip replacement in Korean patients? Details of sexual activity and concerns were obtained using a questionnaire designed specifically for the study. The questionnaire was administered to 64 patients in a face-to-face interview at an outpatient clinic. Preoperatively, 53.1% of patients experienced difficulties, primarily due to hip pathology and limitations of motion. The median time to the resumption of sexual activity was 3 months postoperatively, and most patients had no increase in the frequency of sexual activity after the total hip replacement. In 39.1% of patients were seen having difficulties with leg positioning following total hip replacement, and they were likely to change coital positions. The most common concern regarding sexual activity of patients was the fear of dislocation. Furthermore, patients with a higher stress level had lower satisfaction rates. Most patients were unable to obtain information on sexual activity following the total hip arthroplasty, and they did not consult with a physician due to the private nature of the topic. Dislocation was the most common concern of patients during sexual activity following a total hip arthroplasty, and a higher stress level was found to be associated with a lower satisfaction rate. Because most patients were unprepared to consult a physician, the provision of appropriate information before a consultation might be beneficial.
Yoon, Byung-Ho; Lee, Kyung-Hag; Noh, Serae; Ha, Yong-Chan; Koo, Kyung-Hoi
2013-01-01
Background Concerns of patients on sexual activity after total hip arthroplasty have not been well studied in Asian patients. This study aimed to determine the following: (1) what are the concerns of patients related to sexual activity after total hip arthroplasty? (2) what are the changes in sexual activity after total hip replacement in Korean patients? Methods Details of sexual activity and concerns were obtained using a questionnaire designed specifically for the study. The questionnaire was administered to 64 patients in a face-to-face interview at an outpatient clinic. Results Preoperatively, 53.1% of patients experienced difficulties, primarily due to hip pathology and limitations of motion. The median time to the resumption of sexual activity was 3 months postoperatively, and most patients had no increase in the frequency of sexual activity after the total hip replacement. In 39.1% of patients were seen having difficulties with leg positioning following total hip replacement, and they were likely to change coital positions. The most common concern regarding sexual activity of patients was the fear of dislocation. Furthermore, patients with a higher stress level had lower satisfaction rates. Most patients were unable to obtain information on sexual activity following the total hip arthroplasty, and they did not consult with a physician due to the private nature of the topic. Conclusions Dislocation was the most common concern of patients during sexual activity following a total hip arthroplasty, and a higher stress level was found to be associated with a lower satisfaction rate. Because most patients were unprepared to consult a physician, the provision of appropriate information before a consultation might be beneficial. PMID:24340146
Łyp, Marek; Kaczor, Ryszard; Cabak, Anna; Tederko, Piotr; Włostowska, Ewa; Stanisławska, Iwona; Szypuła, Jan; Tomaszewski, Wiesław
2016-07-25
BACKGROUND Pain associated with coxarthrosis, typically occurring in middle-aged and elderly patients, very commonly causes considerable limitation of motor fitness and dependence on pharmacotherapy. This article provides an assessment of a rehabilitation program with tailored water exercises in patients with osteoarthritis before and after total hip replacement. MATERIAL AND METHODS A total of 192 patients (the mean age 61.03±10.89) suffering from hip osteoarthritis (OA) were evaluated before and after total hip replacement (THR). The clinical study covered measurements of hip active ranges of motion (HAROM) and the forces generated by pelvis stabilizer muscles. Pain intensity was assessed according to analogue-visual scale of pain (VAS) and according to the Modified Laitinen Questionnaire. The patients were divided into 6 groups (4 treatment and 2 control). We compared 2 rehabilitation programs using kinesitherapy and low-frequency magnetic field. One of them also had specially designed exercises in the water. Statistical analysis was carried out at the significance level α=0.05. This was a cross-sectional study. RESULTS A positive effect of water exercises on a number of parameters was found in patients with OA both before and after total hip replacement surgery. We noted a significant reduction of pain (p<0.001), increased ranges of motion and muscle strength, and reduced use of medicines (NASAIDs) (p<0.001). A correlation was found between the degree of degenerative deforming lesions and the effects of the treatment process (p<0.01). CONCLUSIONS 1. The rehabilitation program including water exercises most significantly reduced pain in patients with OA before and after total hip replacement surgery. 2. Inclusion of water exercises in a rehabilitation program can reduce the use of medicines in patient with OA and after THR.
Walking efficiency before and after total hip replacement.
Brown, M; Hislop, H J; Waters, R L; Porell, D
1980-10-01
The energy cost of walking and gait characteristics of patients with hip disease were studied to determine changes in walking efficiency following total hip replacement. Twenty-nine patients, 24 with unilateral hip disease and 5 with bilateral hip disease, were tested preoperatively and at various times postoperatively. Oxygen uptake was measured by a modified Douglas bag procedure. The temporal and distance characteristics of gait were measured with contact closing heel switches. Results showed postoperative increases in velocity, cadence, and stride length in patients with unilateral disease and with bilateral disease with bilateral replacement. After surgery, energy cost tended toward more normal levels, but the subjects were not within normal limits for oxygen uptake per minute, oxygen uptake per distance walked, or percent of predicted maximum aerobic capacity. Comparison of energy expenditure data with temporal and distance factors of gait indicated that all subjects became more physiologically efficient after hip replacement.
Harikesavan, Karvannan; Chakravarty, Raj D; Maiya, Arun G; Hegde, Sanjay P; Y Shivanna, Shivakumar
2017-01-01
Total knee replacement (TKR) is the commonest surgical procedure for patients with severe pain and impaired physical function following end stage knee osteoarthritis. The hip abductors are well renowned in stabilization of the trunk and hip during walking, maintaining the lower limb position, and transferring the forces from the lower limbs to the pelvis. To assess the efficacy of hip abductor strengthening exercise on functional outcome using performance based outcome measures following total knee replacement. An observer blinded randomized pilot trial design was conducted at Manipal hospital, Bangalore, India. Participants designated for elective TKR were randomized to experimental group hip abductor strengthening along with standard rehabilitation (n=10) or control group standard rehabilitation alone (n=10). Participants followed for one year to assess physical function using performance based outcomes, such as timed up and go test, single leg stance test, six minute walk test, knee extensor strength and hip abductor strength. Eighteen participants with a mean age of 63.1 ± 5.5 years (8 Males and 10 Females) completed the study. Improvement in hip abduction strength, single leg stand test was superior in hip abductor strengthening group at 3 months and 1 year when compared to standard rehabilitation alone. Hip abductor strengthening showed superior improvements in single leg stance test and six minute walk test. Hip abductor strengthening exercises has the potential to improve physical function following total knee replacement.
Harikesavan, Karvannan; Chakravarty, Raj D.; Maiya, Arun G; Hegde, Sanjay P.; Y. Shivanna, Shivakumar
2017-01-01
Background: Total knee replacement (TKR) is the commonest surgical procedure for patients with severe pain and impaired physical function following end stage knee osteoarthritis. The hip abductors are well renowned in stabilization of the trunk and hip during walking, maintaining the lower limb position, and transferring the forces from the lower limbs to the pelvis. Objective: To assess the efficacy of hip abductor strengthening exercise on functional outcome using performance based outcome measures following total knee replacement. Methods: An observer blinded randomized pilot trial design was conducted at Manipal hospital, Bangalore, India. Participants designated for elective TKR were randomized to experimental group hip abductor strengthening along with standard rehabilitation (n=10) or control group standard rehabilitation alone (n=10). Participants followed for one year to assess physical function using performance based outcomes, such as timed up and go test, single leg stance test, six minute walk test, knee extensor strength and hip abductor strength. Result: Eighteen participants with a mean age of 63.1 ± 5.5 years (8 Males and 10 Females) completed the study. Improvement in hip abduction strength, single leg stand test was superior in hip abductor strengthening group at 3 months and 1 year when compared to standard rehabilitation alone. Conclusion: Hip abductor strengthening showed superior improvements in single leg stance test and six minute walk test. Hip abductor strengthening exercises has the potential to improve physical function following total knee replacement. PMID:28567148
Kantak, Avadhoot P; Shah, Nirav N
2017-12-01
One of the local factors contributing to the formation of heterotopic ossification includes bone debris generated during the surgery. This risk can be partially nullified by use of saline wash. Our research aim was to ascertain if extensive intraoperative lavage can reduce the incidence and severity of heterotopic ossification in primary total hip arthroplasty. A retrospective case control radiological study of 145 patients (175 hip replacements). The control group received minimal intra-operative lavage (<1,000 mL); consisted of 90 primary hip replacements. The index group received extensive saline lavage (>3,000 mL), and included 85 primary hip replacements. Brooker classification was used to grade radiographs at one year for development of heterotopic ossification. Sixty-six patients in control group had heterotopic ossification, with six showing a significant grade (grade 3 or 4). Thirty-five patients in the index group had heterotopic ossification with no incidence of severe grade. Majority patients in the index group showed a predominantly grade 1 heterotopic ossification; 28 out of 35, as compared to 37 out of 66 in control group. There was a statistically significant difference in the incidence ( P <0.05) as well as severity of heterotopic ossification between the groups ( P <0.05). We conclude that use of extensive lavage during total hip replacement reduces the incidence as well as severity of heterotopic ossification.
Klugarova, Jitka; Klugar, Miloslav; Mareckova, Jana; Gallo, Jiri; Kelnarova, Zuzana
2016-01-01
Total hip replacement is the most effective and safest method for treating severe degenerative, traumatic and other diseases of the hip joint. Total hip replacement can reliably relieve pain and improve function in the majority of patients for a period of 15 to 20 years or more postoperatively. Physical therapy follows each total hip replacement surgery. Physical therapy protocols after total hip replacement in the post-discharge period vary widely in terms of setting (inpatient, outpatient), content (the particular set of exercises used), and frequency (e.g. daily versus twice a week). In current literature, there is no systematic review which has compared the effectiveness of inpatient and outpatient physical therapy in patients after total hip replacement in the post-discharge period. The objective of this systematic review was to compare the effectiveness of inpatient physical therapy with outpatient physical therapy on the quality of life and gait measures in older adults after total hip replacement in the post-discharge period. This review considered studies that include older adults (over 65 years) who have had total hip replacement and are in the post-discharge period. Adults with bilateral or multiple simultaneous surgeries and also patients who have had hemiarthroplasty of the hip joint were excluded.This review considered studies that included any type of physical therapy delivered in inpatient settings provided by professionals with education in physical therapy. Inpatient physical therapy delivered at any frequency and over any duration was included.This review considered studies that included as a comparator any type of physical therapy delivered in outpatient settings provided by professionals with education in physical therapy or no physical therapy.This review considered studies that included the following primary and secondary outcomes. The primary outcome was quality of life, assessed by any validated assessment tool. The secondary outcome was measures of gait assessed by any valid methods.This review considered both experimental and observational study designs including randomized controlled trials, non-randomized controlled trials, quasi-experimental, before and after studies, prospective and retrospective cohort studies, case control studies and analytical cross sectional studies for inclusion. The search strategy aimed to find both published and unpublished studies. A three-step search strategy was utilized in 12 databases. Studies published in all languages and any date were considered for inclusion in this review. Assessment of methodological quality was not conducted as no studies were identified that met the inclusion criteria. Data extraction and synthesis was not performed because no studies were included in this systematic review. During to the three-step search strategy 4330 papers were identified. The primary and secondary reviewer independently retrieved 42 potentially relevant papers according to the inclusion criteria by title and abstract screening. Following assessment of full text all of the retrieved papers were excluded based on the inclusion criteria. There is no scientific evidence comparing the effectiveness of inpatient physical therapy with outpatient physical therapy in older patients after total hip replacement in the post-discharge period. This systematic review has identified gaps in the literature for comparing the effectiveness of inpatient physical therapy with and outpatient physical therapy on the quality of life and gait measures in older adults after total hip replacement in the post-discharge period. Prospective randomized double blind multicenter controlled trials are needed to answer this important clinical question.
Effects of preoperative physiotherapy in hip osteoarthritis patients awaiting total hip replacement
Czyżewska, Anna; Walesiak, Katarzyna; Krawczak, Karolina; Cabaj, Dominika; Górecki, Andrzej
2014-01-01
Introduction The World Health Organization (WHO) claimed osteoarthritis as a civilization-related disease. The effectiveness of preoperative physiotherapy among patients suffering hip osteoarthritis (OA) at the end of their conservative treatment is rarely described in the literature. The aim of this study was to assess the quality of life and musculoskeletal health status of patients who received preoperative physiotherapy before total hip replacement (THR) surgery within a year prior to admission for a scheduled THR and those who did not. Material and methods Forty-five patients, admitted to the Department of Orthopaedics and Traumatology of Locomotor System for elective total hip replacement surgery, were recruited for this study. The assessment consisted of a detailed interview using various questionnaires: the Harris Hip Score (HHS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the 36-Item Short Form Health Survey (SF-36), and the Hip disability and Osteoarthritis Outcome Score (HOOS), as well as physical examination. Patients were assigned to groups based on their attendance of preoperative physiotherapy within a year prior to surgery. Results Among patients who received preoperative physiotherapy a significant improvement was found for pain, daily functioning, vitality, psychological health, social life, and (active and passive) internal rotation (p < 0.05). Conclusions Patients are not routinely referred to physiotherapy within a year before total hip replacement surgery. This study confirmed that pre-operative physiotherapy may have a positive influence on selected musculoskeletal system status indicators and quality of life in hip osteoarthritis patients awaiting surgery. PMID:25395951
Chaudhry, Fouad A; Ismail, Sanaa Z; Davis, Edward T
2018-05-01
Computer-assisted navigation techniques are used to optimise component placement and alignment in total hip replacement. It has developed in the last 10 years but despite its advantages only 0.3% of all total hip replacements in England and Wales are done using computer navigation. One of the reasons for this is that computer-assisted technology increases operative time. A new method of pelvic registration has been developed without the need to register the anterior pelvic plane (BrainLab hip 6.0) which has shown to improve the accuracy of THR. The purpose of this study was to find out if the new method reduces the operating time. This was a retrospective analysis of comparing operating time in computer navigated primary uncemented total hip replacement using two methods of registration. Group 1 included 128 cases that were performed using BrainLab versions 2.1-5.1. This version relied on the acquisition of the anterior pelvic plane for registration. Group 2 included 128 cases that were performed using the newest navigation software, BrainLab hip 6.0 (registration possible with the patient in the lateral decubitus position). The operating time was 65.79 (40-98) minutes using the old method of registration and was 50.87 (33-74) minutes using the new method of registration. This difference was statistically significant. The body mass index (BMI) was comparable in both groups. The study supports the use of new method of registration in improving the operating time in computer navigated primary uncemented total hip replacements.
Hip Replacement - Multiple Languages
... Hip Replacement - العربية (Arabic) Bilingual PDF Health Information Translations Chinese, Simplified (Mandarin dialect) (简体中文) Expand Section Total ... Chinese, Simplified (Mandarin dialect)) Bilingual PDF Health Information Translations Chinese, Traditional (Cantonese dialect) (繁體中文) Expand Section Total ...
Total hip arthroplasty in dwarfism. A case report.
De Fine, Marcello; Traina, Francesco; Palmonari, Massimo; Tassinari, Enrico; Toni, Aldo
2008-05-01
In dwarfism hip arthritis, usually secondary to hip dysplasia, is a common finding at an early age. In these patients a joint replacement is a demanding procedure due to the peculiar joint deformity and the small size of the bones. We present a case of a bilateral hip replacement in a dwarf patient. In order to reduce intraoperative complications and improve the joint kinematics a thorough preoperative planning was performed by a CT based computerised system. On the basis of the planning we chose a conical shaped stem that enable as to restore limb length and offset with a low risk of femoral fracture. In conclusion, we consider total hip replacement in dwarfism a safe and effective procedure if an accurate preoperative planning is performed.
Canine total hip replacement using a cementless threaded cup and stem: a review of 55 cases.
Denny, H R; Linnell, M; Maddox, T W; Comerford, E J
2018-06-01
To determine the long-term results and complications associated with the Helica ® cementless hip endoprosthesis system. Retrospective study of 55 consecutive Helica total hip replacements performed between January 2010 and February 2015. A total of 55 total hip replacements were performed in 50 dogs; 45 dogs had unilateral hip replacements, and five had staged bilateral replacements. A total of 23 first-generation short femoral stems were implanted in 22 dogs, of which nine cases (39%) experienced complications and 19 (86%) recovered satisfactorily when revisions were included; 31 second-generation femoral stems were implanted in 28 dogs, of which 10 cases (32%) experienced complications, and 26 (93%) made satisfactory recoveries, including revisions. In 36 dogs for which data were available, postoperative Liverpool Osteoarthritis in Dogs scores were significantly reduced compared to preoperative scores. Complications occurred in a total of 19 cases (34·5%; 95% confidence interval: 22 to 47·1%); the most common was aseptic loosening of the femoral stem [11 cases (20%; 95% confidence interval: 9·4 to 30·6%)]. Following multivariable analysis, no risk factors were identified for overall complications, but there was a significant association of implant type (first-generation short stem) with loosening (odds ratio 4·9, 95% confidence interval: 1·1 to 22·1, P=0·034). This study found the Helica hip endoprosthesis system to be effective in the management of hip dysplasia and osteoarthritis in dogs. Aseptic loosening of the femoral stem remains the most common complication but appears to have been significantly reduced with the introduction of the second-generation stem. © 2018 British Small Animal Veterinary Association.
Russell, R C; Ghassemi, A; Dorrell, J H; Powles, D P
2009-08-01
The purpose of this study was to evaluate the mid- to long-term survivorship of Bimetric cementless total hip replacement and assess how it is affected by the acetabular design. This was a retrospective analysis of 127 Bimetric cementless total hip replacements in 110 patients with a follow-up of 7-18 years. A single design stem and three different cementless metal-backed acetabular designs were used. Patients were assessed clinically using the Harris hip score and radiologically by independent review of current hip radiographs. There was only one case of aseptic loosening of the femoral stem. The earliest acetabular design showed a high failure rate whilst the latter two designs showed a 96% survivorship at a mean of 9.5 years. We conclude that a combination of the bimetric stem with either of the latter acetabular cup designs has a good mid- to long-term performance.
Burke, Neil G; Green, Connor; McHugh, Gavin; McGolderick, Niall; Kilcoyne, Carol; Kenny, Patrick
2012-08-01
It is important to reduce potential wound complications in total hip and total knee arthroplasty procedures. The purpose of this study was to compare the jubilee dressing method to a standard adhesive dressing. 124 patients (62 total hip replacements and 62 total knee replacements) were randomly selected to have either a standard adhesive dressing or jubilee method dressing. The number of dressing changes, incidence of blistering, leakage, appearance of inflammation, infection rate and the average stay in hospital was recorded for each patient. The jubilee dressing significantly reduced the rate of blistering, leakage and number of dressing changes when compare to a traditional adhesive dressing (p < 0.05). The rate of inflammation and average length of stay in hospital was not significantly different between the two groups. The authors recommend the use of this dressing for total hip and total knee arthroplasty procedures due to the associated lower complication rate. Copyright © 2012 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.
Kurtz, Steven M; Ong, Kevin L; Lau, Edmund; Bozic, Kevin J
2014-04-16
Few studies have explored the role of the National Health Expenditure and macroeconomics on the utilization of total joint replacement. The economic downturn has raised questions about the sustainability of growth for total joint replacement in the future. Previous projections of total joint replacement demand in the United States were based on data up to 2003 using a statistical methodology that neglected macroeconomic factors, such as the National Health Expenditure. Data from the Nationwide Inpatient Sample (1993 to 2010) were used with United States Census and National Health Expenditure data to quantify historical trends in total joint replacement rates, including the two economic downturns in the 2000s. Primary and revision hip and knee arthroplasty were identified using codes from the International Classification of Diseases, Ninth Revision, Clinical Modification. Projections in total joint replacement were estimated using a regression model incorporating the growth in population and rate of arthroplasties from 1993 to 2010 as a function of age, sex, race, and census region using the National Health Expenditure as the independent variable. The regression model was used in conjunction with government projections of National Health Expenditure from 2011 to 2021 to estimate future arthroplasty rates in subpopulations of the United States and to derive national estimates. The growth trend for the incidence of joint arthroplasty, for the overall United States population as well as for the United States workforce, was insensitive to economic downturns. From 2009 to 2010, the total number of procedures increased by 6.0% for primary total hip arthroplasty, 6.1% for primary total knee arthroplasty, 10.8% for revision total hip arthroplasty, and 13.5% for revision total knee arthroplasty. The National Health Expenditure model projections for primary hip replacement in 2020 were higher than a previously projected model, whereas the current model estimates for total knee arthroplasty were lower. Economic downturns in the 2000s did not substantially influence the national growth trends for hip and knee arthroplasty in the United States. These latest updated projections provide a basis for surgeons, hospitals, payers, and policy makers to plan for the future demand for total joint replacement surgery.
Jensen, Carsten; Roos, Ewa M; Kjærsgaard-Andersen, Per; Overgaard, Søren
2013-01-14
The age- and gender-specific incidence of total hip replacement surgery has increased over the last two decades in all age groups. Recent studies indicate that non-surgical interventions are effective in reducing pain and disability, even at later stages of the disease when joint replacement is considered. We hypothesize that the time to hip replacement can be postponed in patients with severe hip osteoarthritis following participation in a patient education and supervised exercise program when compared to patients receiving patient education alone. A prospective, blinded, parallel-group multi-center trial (2 sites), with balanced randomization [1:1]. Patients with hip osteoarthritis and an indication for hip replacement surgery, aged 40 years and above, will be consecutively recruited and randomized into two treatment groups. The active treatment group will receive 3 months of supervised exercise consisting of 12 sessions of individualized, goal-based neuromuscular training, and 12 sessions of intensive resistance training plus patient education (3 sessions). The control group will receive only patient education (3 sessions). The primary end-point for assessing the effectiveness of the intervention is 12 months after baseline. However, follow-ups will also be performed once a year for at least 5 years. The primary outcome measure is the time to hip replacement surgery measured on a Kaplain-Meier survival curve from time of inclusion. Secondary outcome measures are the five subscales of the Hip disability and Osteoarthritis Outcome Score, physical activity level (UCLA activity score), and patient's global perceived effect. Other measures include pain after exercise, joint-specific adverse events, exercise adherence, general health status (EQ-5D-5L), mechanical muscle strength and performance in physical tests. A cost-effectiveness analysis will also be performed. To our knowledge, this is the first randomized clinical trial comparing a patient education plus supervised exercise program to patient education alone in hip osteoarthritis patients with an indication for surgery on the time to total hip replacement. NCT01697241.
Hip and knee replacement in osteogenesis imperfecta.
Papagelopoulos, P J; Morrey, B F
1993-04-01
Five total hip and three total knee arthroplasties were performed, from 1969 to 1990, in six patients who had osteogenesis imperfecta. The patients who had a hip arthroplasty were followed for a mean of seven years, and those who had a knee arthroplasty, for a mean of ten years. Postoperatively, all had relief of pain and were able to walk; one patient used a walker and two used a cane. The only postoperative complication was an intrapelvic protrusion of the acetabular component six years after a bipolar hip replacement.
Matched cohort study of topical tranexamic acid in cementless primary total hip replacement.
Sanz-Reig, Javier; Mas Martinez, Jesus; Verdu Román, Carmen; Morales Santias, Manuel; Martínez Gimenez, Enrique; Bustamante Suarez de Puga, David
2018-03-29
Tranexamic acid has been shown to be effective in reducing blood loss after total hip replacement. The purpose of this study was to prospectively assess the effectiveness of topical TXA use to reduce blood loss after primary total hip replacement and to compare these outcomes with those of a matched control group from a similar cohort that did not have received tranexamic acid. This is a prospective matched control study to assess the effect of a 2 g topical tranexamic acid in 50 mL physiological saline solution in total hip replacement. Primary outcomes were hemoglobin and hematocrit drop, and total blood loss. Secondary outcomes were transfusion rates, length of hospital stay, deep vein thrombosis, and pulmonary embolism events. We could match 100 patients to a control group. There were no statistical significantly differences between the two groups. The hemoglobin and hematocrit postoperative values were significantly higher in topical tranexamic acid group than in control group (P < 0.001). The mean total blood loss was 769 in topical tranexamic acid group and 1163 in control group with significant differences (P = 0.001), which meant 34% reduction in total blood loss. Length of stay was lower in topical tranexamic acid group. The risk of deep vein thrombosis and pulmonary events did not increase. A single dose of 2 g tranexamic acid in 50 mL physiological saline solution topical administration was effective and safe in reducing bleeding in patients undergoing unilateral primary non-cemented total hip replacement compared to a matched control group.
[Optimizing primary total hip replacement--a technique to effect saving of manpower].
Huber, J F; Rink, M; Broger, I; Zumstein, M; Ruflin, G B
2003-01-01
Development of a standardized surgical technique for total hip replacement thereby saving manpower (one assistant) by using a retractor system. Total hip replacement is performed with the patient in a true lateral position on a tunnel cushion. By means of a direct lateral approach the pelvitrochanteric muscles are partially detached using an omega-shaped cut. The Bookwalter retractor is fixed dorsally on the operating table. The ring is centered keeping the greater trochanter in the middle. The Hohmann retractors are fixed to the ring to sufficiently expose the acetabulum. To insert the femoral stem the ring needs to be opened dorsally and the patient's leg is bent 90 degrees in the hip and the knee over the tunnel cushion. The muscles inserting at the greater trochanter are retracted by a separate Hohmann retractor with weight. In a case control study with matched pairs the patients treated with this technique were compared with those treated in supine position with the transgluteal approach. The number of assistants required and the operating time were assessed. All the hip replacements with the patient in side position were performed with one assistant, in supine position with two assistants. The operating time did not differ significantly (supine position 110 min/side position 112 min). The complication rate in both groups was comparable (one secondary wound healing, one transient ischalgia). The process of total hip replacement can be optimized. The described technique allows to spare one surgical assistant without prolonging the operating time.
Aminata, Iman; Lee, Soo-Ho; Chang, Jae-Suk; Lee, Choon-Sung; Chun, Jae-Myeung; Park, Jin-Woong; Pawaskar, Aditya; Jeon, In-Ho
2012-12-15
This study aims to evaluate perioperative mortality and morbidity after total hip replacement in liver transplant recipients and suggesting safety guidelines. Hip replacement surgery is one of the most common elective surgeries even for organ transplant recipients. However, there is a paucity of literature addressing the morbidity and complications of hip replacement surgery for liver transplant recipients. We analyzed retrospectively 33 arthroplasty cases in 20 liver transplant recipients carried out in a single center from 2005 to 2011. All perioperative clinical and laboratory data were evaluated together with early and late morbidity and mortality. Of 2253 liver transplant recipients, 20 (0.9%) patients underwent 33 total hip arthroplasties. Thirty-two arthroplasties were performed for avascular necrosis of the femoral head, whereas only one was performed for osteoarthritis. There was no death, liver failure, or infection within 30 days after surgery. Three patients showed elevated liver enzyme more than 5 times the normal value, but it eventually decreased to normal within 1 week. Of 33 cases of arthroplasty, postoperative blood transfusion was needed in 14 cases with 1 case receiving more than 4 U. On long-term follow-up, no patients have developed periprosthetic fracture, implant loosening, or liver failure. All patients showed good to excellent postoperative Harris hip score. In this series, we can infer that hip replacement surgery in liver transplantation patients is safe and gives a reliably good result. Some preoperative conditions should be obtained to reduce postoperative morbidity.
2012-01-01
Background Studies on leisure time physical activity as risk factor or protective factor for knee or hip osteoarthritis (OA) show divergent results. Longitudinal prospective studies are needed to clarify the association of physical activity with future OA. The aim was to explore in a prospective population-based cohort study the influence of leisure time physical activity on severe knee or hip OA, defined as knee or hip replacement due to OA. Methods Leisure time physical activity was reported by 28320 participants (mean age 58 years (SD 7.6), 60% women) at baseline. An overall leisure time physical activity score, taking both duration and intensity of physical activities into account, was created. The most commonly reported activities were also used for analysis. The incidence of knee or hip replacement due to OA over 11 years was monitored by linkage with the Swedish hospital discharge register. Cox’s proportional hazards model (crude and adjusted for potential confounding factors) was used to assess the incidence of total joint replacement, or osteotomy (knee), in separate analyses of leisure time physical activity. Results There was no significant overall association between leisure time physical activity and risk for knee or hip replacement due to OA over the 11-year observation time. For women only, the adjusted RR (95% CI) for hip replacement was 0.66 (0.48, 0.89) (fourth vs. first quartile), indicating a lower risk of hip replacement in those with the highest compared with the lowest physical activity. The most commonly reported activities were walking, bicycling, using stairs, and gardening. Walking was associated with a lower risk of hip replacement (adjusted RR 0.76 (95% CI 0.61, 0.94), specifically for women (adjusted RR 0.75 (95% CI 0.57, 0.98)). Conclusions In this population-based study of middle-aged men and women, leisure time physical activity showed no consistent overall relationship with incidence of severe knee or hip OA, defined as joint replacement due to OA, over 11 years. For women, higher leisure time physical activity may have a protective role for the incidence of hip replacement. Walking may have a protective role for hip replacement, specifically for women. PMID:22595023
Hu, S; Zhang, Z-Y; Hua, Y-Q; Li, J; Cai, Z-D
2009-07-01
We performed a meta-analysis to evaluate the relative efficacy of regional and general anaesthesia in patients undergoing total hip or knee replacement. A comprehensive search for relevant studies was performed in PubMed (1966 to April 2008), EMBASE (1969 to April 2008) and the Cochrane Library. Only randomised studies comparing regional and general anaesthesia for total hip or knee replacement were included. We identified 21 independent, randomised clinical trials. A random-effects model was used to calculate all effect sizes. Pooled results from these trials showed that regional anaesthesia reduces the operating time (odds ratio (OR) -0.19; 95% confidence interval (CI) -0.33 to -0.05), the need for transfusion (OR 0.45; 95% CI 0.22 to 0.94) and the incidence of thromboembolic disease (deep-vein thrombosis OR 0.45, 95% CI 0.24 to 0.84; pulmonary embolism OR 0.46, 95% CI 0.29 to 0.80). Regional anaesthesia therefore seems to improve the outcome of patients undergoing total hip or knee replacement.
Basic Science Considerations in Primary Total Hip Replacement Arthroplasty
Mirza, Saqeb B; Dunlop, Douglas G; Panesar, Sukhmeet S; Naqvi, Syed G; Gangoo, Shafat; Salih, Saif
2010-01-01
Total Hip Replacement is one of the most common operations performed in the developed world today. An increasingly ageing population means that the numbers of people undergoing this operation is set to rise. There are a numerous number of prosthesis on the market and it is often difficult to choose between them. It is therefore necessary to have a good understanding of the basic scientific principles in Total Hip Replacement and the evidence base underpinning them. This paper reviews the relevant anatomical and biomechanical principles in THA. It goes on to elaborate on the structural properties of materials used in modern implants and looks at the evidence base for different types of fixation including cemented and uncemented components. Modern bearing surfaces are discussed in addition to the scientific basis of various surface engineering modifications in THA prostheses. The basic science considerations in component alignment and abductor tension are also discussed. A brief discussion on modular and custom designs of THR is also included. This article reviews basic science concepts and the rationale underpinning the use of the femoral and acetabular component in total hip replacement. PMID:20582240
Impact of Tranexamic Acid in Total Knee and Total Hip Replacement.
Boyle, Jaclyn A; Soric, Mate M
2017-02-01
To evaluate the net clinical benefit of tranexamic acid use in patients undergoing total knee or total hip replacement. This is a retrospective study of patients undergoing total knee or total hip replacement. The primary outcome was the net clinical benefit of tranexamic acid use. Secondary outcomes included length of stay, incidence of venous thromboembolism, change in hemoglobin, and number of units of blood transfused. Four hundred and six patients were screened for inclusion and 327 patients met inclusion criteria; 174 patients received tranexamic acid versus 153 patients who received usual care. Tranexamic acid demonstrated a positive net clinical benefit versus usual care (40.8% vs 13.7%, P < .01) but did not affect length of stay (3.39 vs 3.37 days, respectively, P = .76). Venous thromboembolism was comparable between groups (2.3% vs 0.7%, P = .38). Average change in hemoglobin and need for transfusion were lower in the treatment group versus the usual care group, respectively (3.46 vs 4.26 mg/dL, P < .01). Tranexamic acid demonstrated a significant benefit in decreasing change in hemoglobin as well as the need for blood transfusion with no increase in the risk of venous thromboembolism in patients undergoing total knee or total hip replacement.
... the skeleton) in people who have had total hip replacement surgery (surgery to replace the hip joint with an artificial joint) or in people ... 8 ounces [180 to 240 mL]) of plain water while you are sitting or standing. Sit or ...
Ghassemi, A.; Dorrell, J. H.; Powles, D. P.
2008-01-01
The purpose of this study was to evaluate the mid- to long-term survivorship of Bimetric cementless total hip replacement and assess how it is affected by the acetabular design. This was a retrospective analysis of 127 Bimetric cementless total hip replacements in 110 patients with a follow-up of 7–18 years. A single design stem and three different cementless metal-backed acetabular designs were used. Patients were assessed clinically using the Harris hip score and radiologically by independent review of current hip radiographs. There was only one case of aseptic loosening of the femoral stem. The earliest acetabular design showed a high failure rate whilst the latter two designs showed a 96% survivorship at a mean of 9.5 years. We conclude that a combination of the bimetric stem with either of the latter acetabular cup designs has a good mid- to long-term performance. PMID:18551293
Birrell, F.; Johnell, O.; Silman, A.
1999-01-01
OBJECTIVES—To estimate the requirement for total hip replacement in the United Kingdom over the next three decades METHODS—Projection of age and sex specific hip replacements in the UK over 10 year intervals taking account of demographic change and the extrapolation of arthroplasty rates from Sweden; a country with recently introduced guidelines. RESULTS—Assuming no change in the age and sex specific arthroplasty rates, the estimated number of hip replacements will increase by 40% over the next 30 year period because of demographic change alone. The proportionate change will be substantially higher in men (51%) than women (33%), with a doubling of the number of male hip replacements in those aged over 85. Changes in the threshold for surgery may increase this further—up to double the current number. CONCLUSION—A sharp rise in hip replacements will be needed to satisfy needs in the UK population over the next 30 years. PMID:10460191
Singh, Jasvinder A; Dowsey, Michelle M; Dohm, Michael; Goodman, Susan M; Leong, Amye L; Scholte Voshaar, Marieke M J H; Choong, Peter F
2017-11-01
Discussion and endorsement of the OMERACT total joint replacement (TJR) core domain set for total hip replacement (THR) and total knee replacement (TKR) for endstage arthritis; and next steps for selection of instruments. The OMERACT TJR working group met at the 2016 meeting at Whistler, British Columbia, Canada. We summarized the previous systematic reviews, the preliminary OMERACT TJR core domain set and results from previous surveys. We discussed preliminary core domains for TJR clinical trials, made modifications, and identified challenges with domain measurement. Working group participants (n = 26) reviewed, clarified, and endorsed each of the inner and middle circle domains and added a range of motion domain to the research agenda. TJR were limited to THR and TKR but included all endstage hip and knee arthritis refractory to medical treatment. Participants overwhelmingly endorsed identification and evaluation of top instruments mapping to the core domains (100%) and use of subscales of validated multidimensional instruments to measure core domains for the TJR clinical trial core measurement set (92%). An OMERACT core domain set for hip/knee TJR trials has been defined and we are selecting instruments to develop the TJR clinical trial core measurement set to serve as a common foundation for harmonizing measures in TJR clinical trials.
Total hip replacement for hip fracture: Surgical techniques and concepts.
Coomber, Ross; Porteous, Matthew; Hubble, Matthew J W; Parker, Martyn J
2016-10-01
When treating a hip fracture with a total hip replacement (THR) the surgical technique may differ in a number of aspects in comparison to elective arthroplasty. The hip fracture patient is more likely to have poor bone stock secondary to osteoporosis, be older, have a greater number of co-morbidities, and have had limited peri-operative work-up. These factors lead to a higher risk of complications, morbidity and perioperative mortality. Consideration should be made to performing the THR in a laminar flow theatre, by a surgeon experienced in total hip arthroplasty, using an anterolateral approach, cementing the implant in place, using a large head size and with repair of the joint capsule. Combined Ortho-geriatric care is recommended with similar post-operative rehabilitation to elective THR patients but with less expectation of short length of stay and consideration for fracture prevention measures. Copyright © 2016. Published by Elsevier Ltd.
Estimation of wear in total hip replacement using a ten station hip simulator.
Brummitt, K; Hardaker, C S
1996-01-01
The results of hip simulator tests on a total of 16 total hip joints, all of them 22.25 mm Charnley designs, are presented. Wear at up to 6.75 million cycles was assessed by using a coordinate measuring machine. The results gave good agreement with clinical estimates of wear rate on the same design of joint replacement from a number of sources. Good agreement was also obtained when comparison was made with the published results from more sophisticated simulators. The major source of variation in the results was found to occur in the first million cycles where creep predominates. The results of this study support the use of this type of simplified simulator for estimating wear in a total hip prosthesis. The capability to test a significant number of joints simultaneously may make this mechanism preferable to more complex machines in many cases.
[Total hip arthroplasty through anterior "minimal invasive" approach].
Moerenhout, Kevin G; Cherix, Stéphane; Rüdiger, Hannes A
2012-12-19
Total hip replacement has seen a tremendous development and has become one of the most successful surgical interventions in orthopaedics. While during the first decades of development of total hip arthroplasty the fixation of the implant into the bone was the main concern, the focus has shifted towards surgical technique and soft tissue handling. In order to avoid permanent soft tissue damage, muscular dysfunction and concerns in regards to cosmetics, minimal invasive and anatomic approaches have been developed. We here provide a short overview on various methods of total hip replacements and we describe our technique through a minimal invasive direct anterior approach. While muscle and nerve damage is minimal, this technique allows for a rapid rehabilitation and is associated with an excellent functional outcome and a minimal risk for dislocation.
The influence of optimism on functionality after total hip replacement surgery.
Balck, Friedrich; Lippmann, Maike; Jeszenszky, Csilla; Günther, Klaus-Peter; Kirschner, Stephan
2016-08-01
Among other factors, optimism has been shown to significantly influence the course of some diseases (cancer, HIV, coronary heart disease). This study investigated whether optimism of a patient before a total hip replacement can predict the functionality of the lower limbs 3 and 6 months after surgery. A total of 325 patients took part in the study (age: 58.7 years; w: 55%). The functionality was measured with the Western Ontario and McMaster Universities arthrosis index, and optimism with the Life Orientation Test. To analyse the influences of age, gender and optimism, general linear models were calculated. In optimistic patients, functionality improved significantly over time. The study showed a clear influence of dispositional optimism on the recovery after total hip replacement in the first 3 months after surgery. © The Author(s) 2015.
Moran, M.; Khan, A.; Sochart, D. H.; Andrew, G.
2003-01-01
A cross-sectional study of 100 surgeons and 370 patients awaiting primary total hip or knee replacement was carried out. Oxford hip or knee score questionnaires were sent to the surgeons and patients. They were asked to predict the level of symptoms expected 6 months following surgery. The Oxford scores derive a value of 12-60, with a greater score indicating worsening symptoms. The mean pre-operative score was 45.12 for the hip patients and 42.96 for the knee patients, and the patients expected this to drop to 23.70 and 25.66, respectively, 6 months' postoperatively. This was a significant difference for both groups. The surgeons expected the patients to have a mean postoperative score of 20.91 for the hip group and 22.19 for the knee group. The surgeons' scores were significantly lower than those from the patients. There was a significant difference between the patients' and surgeons' expectations of the results of total knee and hip replacement surgery. The surgeons expected better results than the patients. We believe that this is the first study that directly compares surgeon and patient expectations of lower limb arthroplasty. PMID:12831497
Gheorghiu, Daniel; Peter, Viju; Lynch, Martin
2010-02-01
The teflon hip arthroplasty design was used by Sir John Charnley in the early 60's but was taken off the market due to high complication rates. A case is reported of an intrapelvic granuloma after total hip arthroplasty following the use of a teflon socket. This appears to be the last surviving patient treated by Sir John Charnley using a Teflon hip socket design.
The cost analysis of cemented versus cementless total hip replacement operations on the NHS.
Kallala, R; Anderson, P; Morris, S; Haddad, F S
2013-07-01
In a time of limited resources, the debate continues over which types of hip prosthesis are clinically superior and more cost-effective. Orthopaedic surgeons increasingly need robust economic evidence to understand the full value of the operation, and to aid decision making on the 'package' of procedures that are available and to justify their practice beyond traditional clinical preference. In this paper we explore the current economic debate about the merits of cemented and cementless total hip replacement, an issue that continues to divide the orthopaedic community.
[Minimally invasive approaches to hip and knee joints for total joint replacement].
Rittmeister, M; König, D P; Eysel, P; Kerschbaumer, F
2004-11-01
The manuscript features the different minimally invasive approaches to the hip for joint replacement. These include medial, anterior, anterolateral, and posterior approaches. The concept of minimally invasive hip arthroplasty makes sense if it is an integral part of a larger concept to lower postoperative morbidity. Besides minimal soft tissue trauma, this concept involves preoperative patient education, preemptive analgesia, and postoperative physiotherapy. It is our belief that minimal incision techniques for the hip are not suited for all patients and all surgeons. The different minimally invasive approaches to the knee joint for implantation of a knee arthroplasty are described and discussed. There have been no studies published yet that fulfill EBM criteria. The data so far show that minimally invasive approaches and implantation techniques for total knee replacements lead to quicker rehabilitation of patients.
3D printing technology used in severe hip deformity.
Wang, Shanshan; Wang, Li; Liu, Yan; Ren, Yongfang; Jiang, Li; Li, Yan; Zhou, Hao; Chen, Jie; Jia, Wenxiao; Li, Hui
2017-09-01
This study was designed to assess the use of a 3D printing technique in total hip arthroplasty (THA) for severe hip deformities, where new and improved approaches are needed. THAs were performed from January 2015 to December 2016. Bioprosthesis artificial hip joints were used in both conventional and 3D printing hip arthroplasties. A total of 74 patients (57 cases undergoing conventional hip replacements and 17 undergoing 3D printing hip replacements) were followed-up for an average of 24 months. The average age of the patients was 62.7 years. Clinical data between the patients treated with different approaches were compared. Results showed that the time to postoperative weight bearing and the Harris scores of the patients in the 3D printing group were better than those for patients in the conventional hip replacement group. Unfortunately, the postoperative infection and loosening rates were higher in the 3D printing group. However, there were no significant differences in femoral neck anteversion, neck shaft, acetabular or sharp angles between ipsilateral and contralateral sides in the 3D printing group (P>0.05). The femoral neck anteversion angle was significantly different between the two sides in the conventional hip replacement group (P<0.05). Based on these results, we suggest that the 3D printing approach provides a better short-term curative effect that is more consistent with the physiological structure and anatomical characteristics of the patient, and we anticipate that its use will help improve the lives of many patients.
Saudan, M; Saudan, P; Perneger, T; Riand, N; Keller, A; Hoffmeyer, P
2007-02-01
We examined whether a selective cyclooxygenase-2 (COX-2) inhibitor (celecoxib) was as effective as a non-selective inhibitor (ibuprofen) for the prevention of heterotopic ossification following total hip replacement. A total of 250 patients were randomised to receive celecoxib (200 mg b/d) or ibuprofen (400 mg t.d.s) for ten days after surgery. Anteroposterior radiographs of the pelvis were examined for heterotopic ossification three months after surgery. Of the 250 patients, 240 were available for assessment. Heterotopic ossification was more common in the ibuprofen group (none 40.7% (50), Brooker class I 46.3% (57), classes II and III 13.0% (16)) than in the celecoxib group (none 59.0% (69), Brooker class I 35.9% (42), classes II and III 5.1% (6), p=0.002). Celecoxib was more effective than ibuprofen in preventing heterotopic bone formation after total hip replacement.
[Hip resurfacing arthroplasty].
Witzleb, W-C; Knecht, A; Beichler, T; Köhler, T; Günther, K-P
2004-11-01
In comparison to stemmed total hip replacements, hip resurfacing offers advantages especially in joint stability and amount of femoral bone resection. After the poor results achieved with this concept that were mainly caused by failure of the materials used, reintroduction of the metal-on-metal bearing initiated a renaissance. This bearing, the cementless cup, and the improved surgical technique led to better short- to medium-term results. Revision and complication rates are now comparable to conventional total hip replacements. The functional capacity of the method is higher. Because long-term results are not available, however, questions remain, for instance, the consequences of the higher metal ion serum concentrations or the impossibility of changing the inlay when femoral revision becomes necessary.
2016-08-03
Rheumatoid Arthritis; Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis
Gascoyne, Trevor C; Dyrkacz, Richard M; Turgeon, Thomas R; Burnell, Colin D; Wyss, Urs P; Brandt, Jan-M
2014-10-01
Eight retrieved metal-on-metal total hip replacements displayed corrosion damage along the cobalt-chromium alloy liner taper junction with the Ti alloy acetabular shell. Scanning electron microscopy indicated the primary mechanism of corrosion to be grain boundary and associated crevice corrosion, which was likely accelerated through mechanical micromotion and galvanic corrosion resulting from dissimilar alloys. Coordinate measurements revealed up to 4.3mm(3) of the cobalt-chromium alloy taper surface was removed due to corrosion, which is comparable to previous reports of corrosion damage on head-neck tapers. The acetabular liner-shell taper appears to be an additional source of metal corrosion products in modular total hip replacements. Patients with these prostheses should be closely monitored for signs of adverse reaction towards corrosion by-products. Copyright © 2014 Elsevier Inc. All rights reserved.
Higashi, Hideki; Barendregt, Jan J.
2011-01-01
Background Osteoarthritis constitutes a major musculoskeletal burden for the aged Australians. Hip and knee replacement surgeries are effective interventions once all conservative therapies to manage the symptoms have been exhausted. This study aims to evaluate the cost-effectiveness of hip and knee replacements in Australia. To our best knowledge, the study is the first attempt to account for the dual nature of hip and knee osteoarthritis in modelling the severities of right and left joints separately. Methodology/Principal Findings We developed a discrete-event simulation model that follows up the individuals with osteoarthritis over their lifetimes. The model defines separate attributes for right and left joints and accounts for several repeat replacements. The Australian population with osteoarthritis who were 40 years of age or older in 2003 were followed up until extinct. Intervention effects were modelled by means of disability-adjusted life-years (DALYs) averted. Both hip and knee replacements are highly cost effective (AUD 5,000 per DALY and AUD 12,000 per DALY respectively) under an AUD 50,000/DALY threshold level. The exclusion of cost offsets, and inclusion of future unrelated health care costs in extended years of life, did not change the findings that the interventions are cost-effective (AUD 17,000 per DALY and AUD 26,000 per DALY respectively). However, there was a substantial difference between hip and knee replacements where surgeries administered for hips were more cost-effective than for knees. Conclusions/Significance Both hip and knee replacements are cost-effective interventions to improve the quality of life of people with osteoarthritis. It was also shown that the dual nature of hip and knee OA should be taken into account to provide more accurate estimation on the cost-effectiveness of hip and knee replacements. PMID:21966520
Li, Wei; Zhou, Yi-Xin; Wu, Jian; Xu, Hui; Ji, Song-Jie
2009-02-15
To evaluate the bone refilling in the interface between the trabecular metal (TM) acetabular shell and the bone surface according to consecutive X film measuring after surgery. From July 2006 to July 2007, 35 patients (40 hips) accepted total hip replacement using trabecular metal monoblock acetabular cup system (TM). The cup was made of a ellipse shaped press fit Tantalum shell and high cross-linked PE liner (Longevity) with 28 mm inner diameter. The patients demography was: 16 male (20 hips), 19 female (20 hips), 5 bilateral hip replacements, age from 41 - 71 (mean 53), including 18 avascular necrosis hips, 16 osteoarthritis hips (including those secondary to a dysplasia hip), 4 avascular necrosis hips after femoral neck fracture, 2 Ankylosis Spondylitis. All the 40 total hip replacements used posterior approach, using hemispherical acetabular reamer and 2 mm press fit of final metal shell without screw fixation. The consecutive X film was taken at the end time of surgery and 2, 6, 12, 24 weeks, and 12 months. The clinical results was evaluate according to Harris scoring system, and the standard pelvis AP X film was measured at the interface between metal shell and the acetabular bone surface, witch was divided into five regions (A, B, C, D, E). Totally 32 patients (37 hips) were followed with average 8.7 months (7 - 12 months). The Harris before surgery was 50.5 (32 - 85), promoted to 91.0 (72 - 100), including 29 excellent, 6 good, 2 fair, and the total excellent and good rate was 94.6%. Complications include 4 patients leg length discrepancy from 1 - 2 cm, 3 patients moderate thigh pain and released after conservative therapy. No infection and dislocation was found. Twenty-one patients (23 hips) were found lucent line at the bone-metal interface from 1 - 5 mm, most common in B region and BC boundary than C, D, and CD boundary. All the patients followed was found the lucent line disappeared and refilled with bone at X film 24 weeks after surgery, however, no patients was found osteolysis and cup migration. The trabecular metal has strong capacity of bone conductive and bone inducement.
Standifird, Tyler W; Saxton, Arnold M; Coe, Dawn P; Cates, Harold E; Reinbolt, Jeffrey A; Zhang, Songning
2016-01-01
This study compared biomechanics during stair ascent in replaced and non-replaced limbs of total knee arthroplasty (TKA) patients with control limbs of healthy participants. Thirteen TKA patients and fifteen controls performed stair ascent. Replaced and non-replaced knees of TKA patients were less flexed at contact compared to controls. The loading response peak knee extension moment was greater in control and non-replaced knees compared with replaced. The push-off peak knee abduction moment was elevated in replaced limbs compared to controls. Loading and push-off peak hip abduction moments were greater in replaced limbs compared to controls. The push-off peak hip abduction moment was greater in non-replaced limbs compared to controls. Future rehabilitation protocols should consider the replaced knee and also the non-replaced knee and surrounding joints. Copyright © 2016 Elsevier Inc. All rights reserved.
Online follow-up after total hip replacement: a first case
Dexter, Caroline; Bradley, Benjamin; Williams, Daniel H
2013-01-01
With the current challenging financial climate in the NHS there is an increasing drive to reduce the number of postoperative follow-up appointments. We report on a patient who has successfully used a new online platform, www.myclinicaloutcomes.co.uk, to record condition-specific and generic wellbeing scores following total hip replacement. This case highlights the potential for remote follow-up of routine postoperative patients. PMID:23396931
Biau, D J; Meziane, M; Bhumbra, R S; Dumaine, V; Babinet, A; Anract, P
2011-09-01
The purpose of this study was to define immediate post-operative 'quality' in total hip replacements and to study prospectively the occurrence of failure based on these definitions of quality. The evaluation and assessment of failure were based on ten radiological and clinical criteria. The cumulative summation (CUSUM) test was used to study 200 procedures over a one-year period. Technical criteria defined failure in 17 cases (8.5%), those related to the femoral component in nine (4.5%), the acetabular component in 32 (16%) and those relating to discharge from hospital in five (2.5%). Overall, the procedure was considered to have failed in 57 of the 200 total hip replacements (28.5%). The use of a new design of acetabular component was associated with more failures. For the CUSUM test, the level of adequate performance was set at a rate of failure of 20% and the level of inadequate performance set at a failure rate of 40%; no alarm was raised by the test, indicating that there was no evidence of inadequate performance. The use of a continuous monitoring statistical method is useful to ensure that the quality of total hip replacement is maintained, especially as newer implants are introduced.
Ting, Chao-Fong; Chou, Hsiu-Ling; Chen, Ming-Mie
2006-02-01
This project was aimed at improving the nursing of patients who have undergone total hip replacements. Investigation showed the following problems with existing nursing instruction in this area: lack of standard instruction, outdated educational materials, a 33.75% rate of completion of instruction lack of familiarity with instruction materials, and an average satisfaction score of 2.56 among nurses who have undergone instruction; The reading for patient's satisfaction with the guidance of nurses was 2.04. After site investigation, status analysis and reference check, we proposed the following program. (1) Establish standards and monitor tools for instruction for nursing total hip replacement patients, including "Caring standard", "Guidance for nursing instruction", "Nursing instruction sheet", "Notes at nursing instruction", "Satisfaction scoring system for nursing instruction"; (2) Carry out a training course to enhance nursing staff's knowledge about caring for patients with total hip replacement. After program had been implemented, a completion rate of 88.56% was achieved, and the satisfaction scores among nursing staff and patients were 4.3 and 4.36 respectively. This result shows that when we undertake reform at various different levels--including systemic structure, processing and monitoring--this can radically improve the quality of nursing instruction.
Early failure of total hip replacements implanted at distant hospitals to reduce waiting lists.
Ciampolini, Jac; Hubble, Matthew J. W.
2005-01-01
AIM: In the years 1990-1993, in an effort to reduce waiting-list time, a small number of patients were sent from Exeter to hospitals in London to undergo elective total hip replacement. No medium- or long-term follow-up was arranged. Our aim was to audit the outcome of these hip replacements. PATIENTS AND METHODS: Review of the records of the referring medical practices, Regional Health Authority, local orthopaedic hospital and the distant centres at which the surgery was performed identified 31 cases. A total of 27 hip replacements in 24 patients were available for clinical and radiological review. RESULTS: 12 (44%) hips have so far required revision surgery, at a mean of 6.5 years. Of these, three (11%) have been for deep infection. A further three hips (11%) are radiologically loose and are being closely monitored. Two patients (7%) suffered permanent sciatic nerve palsy. CONCLUSIONS: Patients whose surgery was performed locally over a similar time period have a published failure rate of only 4.9%. This difference is highly statistically significant (P < 0.001). The causes for such a difference in outcome were analysed and include surgical technique, implant selection and absence of follow-up. In the light of this evidence, we would like to urge the government to address waiting list problems by investing in the local infrastructure. Expanding those facilities where properly audited and fully accountable surgeons operate must be the way forward. PMID:15720905
Makki, D; Deierl, K; Pandit, A; Trakru, S
2014-09-01
The aim of this prospective study was to investigate the risk of contamination of surgical gloves during preparation and draping in joint replacement surgery. During 46 hip and knee replacement procedures, the gloves of orthopaedic consultants (n=5) and registrars (n=3) were assessed for contamination immediately after draping by impression of gloved fingers on blood agar. Contamination was evaluated by the surgeon's grade, the type of procedure, the role of the assistant and the dominance of the hand. A total of 125 pairs of top gloves were examined (79 pairs from registrars and 46 pairs from consultants). Bacterial contamination was isolated on 19 pairs (15.2%) (16 pairs from registrars and 3 pairs from consultants, p=0.04). Coagulase negative staphylococci were the main isolates and contamination was considered low in all cases (1-5 colonies). Contamination was seen more on the dominant hand (16 gloves from dominant hands and 6 from non-dominant hands, p=0.04), on the index finger and thumb. More contaminated gloves were seen in hip arthroplasty procedures (16 pairs from total hip replacements vs 3 pairs from total knee replacements, p=0.02). Contamination of glove fingertips during draping in joint replacement procedures is more likely to occur among junior surgeons, in hip rather than knee arthroplasty procedures and on the dominant hand. It is therefore essential that surgeons of different grades replace gloves used in draping to avoid exposing patients to the risk of infection.
Cobalt toxicity after revision total hip replacement due to fracture of a ceramic head.
Pelayo-de Tomás, J M; Novoa-Parra, C; Gómez-Barbero, P
Symptomatic cobalt toxicity from a failed total hip replacement is a rare, but devastating complication. Potential clinical findings include cardiomyopathy, hypothyroidism, skin rash, visual and hearing impairment, polycythaemia, weakness, fatigue, cognitive impairment, and neuropathy. The case is presented of a 74year-old man in whom, after a ceramic-ceramic replacement and two episodes of prosthetic dislocation, it was decided to replace it with a polyethylene-metal total hip arthroplasty (THA). At 6months after the revision he developed symptoms of cobalt toxicity, confirmed by analytical determination (serum cobalt level=651.2μg/L). After removal of the prosthesis, the levels of chromium and cobalt in blood and urine returned to normal, with the patient currently being asymptomatic. It is recommended to use a new ceramic on ceramic bearing at revision, in order to minimise the risk of wear-related cobalt toxicity following breakage of ceramic components. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
A review of virtual reality based training simulators for orthopaedic surgery.
Vaughan, Neil; Dubey, Venketesh N; Wainwright, Thomas W; Middleton, Robert G
2016-02-01
This review presents current virtual reality based training simulators for hip, knee and other orthopaedic surgery, including elective and trauma surgical procedures. There have not been any reviews focussing on hip and knee orthopaedic simulators. A comparison of existing simulator features is provided to identify what is missing and what is required to improve upon current simulators. In total 11 hip replacements pre-operative planning tools were analysed, plus 9 hip trauma fracture training simulators. Additionally 9 knee arthroscopy simulators and 8 other orthopaedic simulators were included for comparison. The findings are that for orthopaedic surgery simulators in general, there is increasing use of patient-specific virtual models which reduce the learning curve. Modelling is also being used for patient-specific implant design and manufacture. Simulators are being increasingly validated for assessment as well as training. There are very few training simulators available for hip replacement, yet more advanced virtual reality is being used for other procedures such as hip trauma and drilling. Training simulators for hip replacement and orthopaedic surgery in general lag behind other surgical procedures for which virtual reality has become more common. Further developments are required to bring hip replacement training simulation up to date with other procedures. This suggests there is a gap in the market for a new high fidelity hip replacement and resurfacing training simulator. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Adventure sports and sexual freedom hip replacement: the tripolar hip.
Pritchett, James W
2018-01-01
Certain athletic activities and lifestyles require a completely stable and very mobile hip. Total hip replacement with a natural femoral head size and two mobile-bearing surfaces (i.e., a "tripolar" prosthesis) is the most stable prosthesis. Elegant design and wear-resistant bearing surfaces are the keys to long-term implant survivorship. The hypothesis is that a ceramic-coated tripolar prosthesis using highly cross-linked polyethylene can provide full function and complete stability with low wear. This study sought to determine: (1) patient-reported outcomes, (2) functional outcomes, (3) implant survivorship and complications, and (4) postoperative sexual limitations. Between 1998 and 2011, the author performed 160 primary total hip replacements using tripolar prostheses in patients participating in adventure sports and other physically demanding activities. The institutional review board approved this study. The inclusion criteria were patients who needed unrestricted activity and who were not candidates for or did not choose hip resurfacing. Patients were followed every second year and assessed with radiographs, Harris Hip Score, WOMAC, SF-12, and UCLA functional outcome scores. Patients were asked about symptoms of instability and satisfaction with their hip replacement. Patients were asked both preoperatively and 2 years postoperatively four questions about their sexual activity. Mean follow-up was 11 years. At 2 years' postoperatively, 98% of patients reported their satisfaction as excellent or good and 99% were not limited for sexual activity following surgery. Seventy-four percent of patients reported they were recovered within 6 weeks of surgery. There were no dislocations. There were three revision procedures for implant loosening, infection, and periprosthetic fracture, but there were no failures of the tripolar articulation. The mean postoperative UCLA score was the highly athletic score of 8. There were no signs of osteolysis, wear, or metal sensitivity reactions. The range of motion achieved, sexual, and functional outcomes were higher than with other types of total hip replacement. This ceramic-coated tripolar prosthesis using highly cross-linked polyethylene provides full function, complete stability, and low wear to younger, active patients, thus confirming the hypothesis and clinical relevance.
Long-term outcome of total hip arthroplasty in patients with haemophilia.
Strauss, A C; Rommelspacher, Y; Nouri, B; Bornemann, R; Wimmer, M D; Oldenburg, J; Pennekamp, P H; Schmolders, J
2017-01-01
Besides the target joints (elbow, knee and ankle), the hip is one of the commonly affected joints in haemophilic arthropathy. Hip arthroplasty is the therapy of choice after failure of conservative treatment. There are only limited data on long-term results after primary total hip arthroplasty (THA). The aim of this retrospective study was to analyse clinical outcome and complication rate after total hip replacement in patients with severe haemophilic arthropathy. Forty-three patients with haemophilia (PWH), one patient with von Willebrand disease and one patient with a Factor-VII-deficiency undergoing 49 total hip arthroplasties, were evaluated in a retrospective study. Harris hip score (HHS), range of motion (ROM), pain status (visual analogue scale, VAS) complication rate and patient satisfaction were assessed at a mean follow-up of 11.5 years (range: 3-32). HSS, ROM and VAS improved significantly combined with high patient satisfaction. In total, three (6.1%) periprosthetic infections and five (10.2%) aseptic implant loosenings occurred after THA leading to revision arthroplasty. In two (4.1%) cases, a pseudotumour and one (2.0%) periarticular ossification had to be resected after THA. Total hip replacement in PWH leads to a significant increase of function, reduction of pain and a high satisfaction. Due to the relatively high complication rate (infections and aseptic loosening) compared to patients without haemophilia, an individual assessment of the risk-benefit ratio from surgical and haemostaseological point of view is needed. © 2016 John Wiley & Sons Ltd.
2016-10-06
Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis; Perthes Disease
Deierl, K; Pandit, A; Trakru, S
2014-01-01
Introduction The aim of this prospective study was to investigate the risk of contamination of surgical gloves during preparation and draping in joint replacement surgery. Methods During 46 hip and knee replacement procedures, the gloves of orthopaedic consultants (n=5) and registrars (n=3) were assessed for contamination immediately after draping by impression of gloved fingers on blood agar. Contamination was evaluated by the surgeon’s grade, the type of procedure, the role of the assistant and the dominance of the hand. Results A total of 125 pairs of top gloves were examined (79 pairs from registrars and 46 pairs from consultants). Bacterial contamination was isolated on 19 pairs (15.2%) (16 pairs from registrars and 3 pairs from consultants, p=0.04). Coagulase negative staphylococci were the main isolates and contamination was considered low in all cases (1–5 colonies). Contamination was seen more on the dominant hand (16 gloves from dominant hands and 6 from non-dominant hands, p=0.04), on the index finger and thumb. More contaminated gloves were seen in hip arthroplasty procedures (16 pairs from total hip replacements vs 3 pairs from total knee replacements, p=0.02). Conclusions Contamination of glove fingertips during draping in joint replacement procedures is more likely to occur among junior surgeons, in hip rather than knee arthroplasty procedures and on the dominant hand. It is therefore essential that surgeons of different grades replace gloves used in draping to avoid exposing patients to the risk of infection. PMID:25198974
Total Hip Joint Replacement Biotelemetry System
NASA Technical Reports Server (NTRS)
Boreham, J. F.; Postal, R. B.; Luntz, R. A.
1981-01-01
The development of a biotelemetry system that is hermetically sealed within a total hip replacement implant is reported. The telemetry system transmits six channels of stress data to reconstruct the major forces acting on the neck of the prosthesis and uses an induction power coupling technique to eliminate the need for internal batteries. The activities associated with the telemetry microminiaturization, data recovery console, hardware fabrications, power induction systems, electrical and mechanical testing and hermetic sealing test results are discussed.
The tribology of metal-on-metal total hip replacements.
Scholes, S C; Unsworth, A
2006-02-01
Total hip surgery is an effective way of alleviating the pain and discomfort caused by diseased or damaged joints. However, in the majority of cases, these joints have a finite life. The main reason for failure is osteolysis (bone resorption). It is well documented that an important cause of osteolysis, and therefore the subsequent loosening and failure of conventional metal- or ceramic-on-ultra-high molecular weight polyethylene joints, is the body's immunological response to the polyethylene wear particles. To avoid this, interest has been renewed in metal-on-metal joints. The intention of this paper is to review the studies that have taken place within different laboratories to determine the tribological performance of new-generation metal-on-metal total hip replacements. These types of joint offer a potential solution to enhance the longevity of prosthetic hip systems; however, problems may arise owing to the effects of metal ion release, which are, as yet, not fully understood.
NASA Astrophysics Data System (ADS)
Arirajan, K. A.; Chockalingam, K.; Vignesh, C.
2018-04-01
Implants are the artificial parts to replace the missing bones or joints in human anatomy to give mechanical support. Hip joint replacement is an important issue in orthopaedic surgery. The main concern limiting the long-run success of the total hip replacement is the limited service life. Hip replacement technique is widely used in replacing the femur head and acetabular cup by materials that are highly biocompatible. The success of the artificial hip replacement depends upon proper material selection, structure, and shape of the hip prosthesis. Many orthopaedic analyses have been tried with different materials, but ended with partial success on the application side. It is a critical task for selecting the best material pair in the hip prosthesis design. This work develops the finite element analysis of an artificial hip implant to study highest von Mises stress, contact pressure and elastic strain occurs for the dissimilar material combination. The different bearing couple considered for the analysis are Metal on Metal, Metal on Plastic, Metal on Ceramic, Ceramic on Plastic, Ceramic on Ceramic combinations. The analysis is carried out at different static positions of a human (i.e) standing, sitting. The results reveals that the combination with metal in contact with plastic (i.e) Titanium femoral head paired with Ultra High Molecular Weight Poly Ethylene acetabular cup reduces maximum von Mises stress and also it gives lowest contact pressure than other combination of bearing couples.
Experience with Designing and Implementing a Bundled Payment Program for Total Hip Replacement
Whitcomb, Winthrop F.; Lagu, Tara; Krushell, Robert J.; Lehman, Andrew P.; Greenbaum, Jordan; McGirr, Joan; Pekow, Penelope S.; Calcasola, Stephanie; Benjamin, Evan; Mayforth, Janice; Lindenauer, Peter K.
2015-01-01
Background Bundled payments, also known as episode-based payments, are intended to contain health care costs and promote quality. In 2011 a bundled payment pilot program for total hip replacement was implemented by an integrated health care delivery system in conjunction with a commercial health plan subsidiary. In July 2015 the Centers for Medicare & Medicaid Services (CMS) proposed the Comprehensive Care for Joint Replacement Model to test bundled payment for hip and knee replacement. Methods Stakeholders were identified and a structure for program development and implementation was created. An Oversight Committee provided governance over a Clinical Model Subgroup and a Financial Model Subgroup. Results The pilot program included (1) a clinical model of care encompassing the period from the preoperative evaluation through the third postoperative visit, (2) a pricing model, (3) a program to share savings, and (4) a patient engagement and expectation strategy. Compared to 32 historical controls— patients treated before bundle implementation—45 post-bundle-implementation patients with total hip replacement had a similar length of hospital stay (3.0 versus 3.4 days, p = .24), higher rates of discharge to home or home with services than to a rehabilitation facility (87% versus 63%), similar adjusted median total payments ($22,272 versus $22,567, p = .43), and lower median posthospital payments ($704 versus $1,121, p = .002), and were more likely to receive guideline-consistent care (99% versus 95%, p = .05). Discussion The bundled payment pilot program was associated with similar total costs, decreased posthospital costs, fewer discharges to rehabilitation facilities, and improved quality. Successful implementation of the program hinged on buy-in from stakeholders and close collaboration between stakeholders and the clinical and financial teams. PMID:26289235
Experience with Designing and Implementing a Bundled Payment Program for Total Hip Replacement.
Whitcomb, Winthrop F; Lagu, Tara; Krushell, Robert J; Lehman, Andrew P; Greenbaum, Jordan; McGirr, Joan; Pekow, Penelope S; Calcasola, Stephanie; Benjamin, Evan; Mayforth, Janice; Lindenauer, Peter K
2015-09-01
Bundled payments, also known as episode-based payments, are intended to contain health care costs and promote quality. In 2011 a bundled payment pilot program for total hip replacement was implemented by an integrated health care delivery system in conjunction with a commercial health plan subsidiary. In July 2015 the Centers for Medicare & Medicaid Services (CMS) proposed the Comprehensive Care for Joint Replacement Model to test bundled payment for hip and knee replacement. Stakeholders were identified and a structure for program development and implementation was created. An Oversight Committee provided governance over a Clinical Model Subgroup and a Financial Model Subgroup. The pilot program included (1) a clinical model of care encompassing the period from the preoperative evaluation through the third postoperative visit, (2) a pricing model, (3) a program to share savings, and (4) a patient engagement and expectation strategy. Compared to 32 historical controls-patients treated before bundle implementation-45 post-bundle-implementation patients with total hip replacement had a similar length of hospital stay (3.0 versus 3.4 days, p=.24), higher rates of discharge to home or home with services than to a rehabilitation facility (87% versus 63%), similar adjusted median total payments ($22,272 versus $22,567, p=.43), and lower median posthospital payments ($704 versus $1,121, p=.002), and were more likely to receive guideline-consistent care (99% versus 95%, p=.05). The bundled payment pilot program was associated with similar total costs, decreased posthospital costs, fewer discharges to rehabilitation facilities, and improved quality. Successful implementation of the program hinged on buy-in from stakeholders and close collaboration between stakeholders and the clinical and financial teams.
Domínguez-Navarro, Fernando; Igual-Camacho, Celedonia; Silvestre-Muñoz, Antonio; Roig-Casasús, Sergio; Blasco, José María
2018-05-01
Balance and proprioceptive deficits are frequently persistent after total joint replacement, limiting functionality and involving altered movement patterns and difficulties in walking and maintaining postural control among patients. The goal of this systematic review was to evaluate the short- and mid-term effects of proprioceptive and balance training for patients undergoing total knee and hip replacement. This is a systematic review of literature. MEDLINE, Embase, Cochrane Library, PEDro, and Scopus were the databases searched. The review included randomized clinical trials in which the experimental groups underwent a training aimed at improving balance and proprioception, in addition to conventional care. The studies had to assess at least one of the following outcomes: self-reported functionality or balance (primary outcomes), knee function, pain, falls, or quality of life. Eight trials were included, involving 567 participants. The quantitative synthesis found a moderate to high significant effect of balance and proprioceptive trainings on self-reported functionality and balance after total knee replacement. The effects were maintained at mid-term in terms of balance alone. Conversely, preoperative training did not enhance outcomes after total hip arthroplasty. The synthesis showed that, in clinical terms, balance trainings are a convenient complement to conventional physiotherapy care to produce an impact on balance and functionality after knee replacement. If outcomes such as improvement in pain, knee range of movement, or patient quality of life are to be promoted, it would be advisable to explore alternative proposals specifically targeting these goals. Further research is needed to confirm or discard the current evidence ultimately, predominantly in terms of the effects on the hips and those yielded by preoperative interventions. Copyright © 2018 Elsevier B.V. All rights reserved.
[Survey on the use and behaviour of metal-metal hip replacements in Spain].
Calcerrada, N; Fernández-Vega, A; Valls-León, C; Garcia-Cimbrelo, E
2016-01-01
Following medical device alerts published in different countries of problems with metal-on-metal total hip replacements, the Spanish Agency of Medicines and Medical Devices (AEMPS) in collaboration with the Spanish Hip Society Surgery designed a national survey to gather information on the use and behaviour of these hip implants. The survey consisted of a questionnaire sent by e-mail to 283 clinical centre recipients of metal-on-metal hips to be filled in by surgeons with expertise in the field. A total of 257 questionnaires were completed. The response rate of the clinical centres was 36.7%. A total of 97.7% of the responses reported that clinical and radiological follow-ups are carried out, and 79.6% undertook metal ion analyses (chromium and cobalt). A large majority (83.6%) of the responders who had who used surface implants, and 70% of those with large-head implants reported peri-operative complications. The most common complication was pain (25% with surface implants and 30.8% with large-head implants). Currently 80.8% of those responding were considering abandoning implanting of these hip replacements. Despite the many limitations to this study, the survey has allowed us to obtain in a quick first view of the implant scenario of Metal on Metal hip implants in Spain, and to determine the type of patient implanted, the time of implantation, and the experience/expertise of the surgeons, and the type of follow-up carried out. Copyright © 2015 SECOT. Published by Elsevier Espana. All rights reserved.
Redesigning a joint replacement program using Lean Six Sigma in a Veterans Affairs hospital.
Gayed, Benjamin; Black, Stephen; Daggy, Joanne; Munshi, Imtiaz A
2013-11-01
In April 2009, an analysis of joint replacement surgical procedures at the Richard L. Roudebush Veterans Affairs Medical Center, Indianapolis, Indiana, revealed that total hip and knee replacements incurred $1.4 million in non-Veterans Affairs (VA) care costs with an average length of stay of 6.1 days during fiscal year 2008. The Joint Replacement Program system redesign project was initiated following the Vision-Analysis-Team-Aim-Map-Measure-Change-Sustain (VA-TAMMCS) model to increase efficiency, decrease length of stay, and reduce non-VA care costs. To determine the effectiveness of Lean Six Sigma process improvement methods applied in a VA hospital. Perioperative processes for patients undergoing total joint replacement were redesigned following the VA-TAMMCS model--the VA's official, branded method of Lean Six Sigma process improvement. A multidisciplinary team including the orthopedic surgeons, frontline staff, and executive management identified waste in the current processes and initiated changes to reduce waste and increase efficiency. Data collection included a 1-year baseline period and a 20-month sustainment period. The primary endpoint was length of stay; a secondary analysis considered non-VA care cost reductions. Length of stay decreased 36% overall, decreasing from 5.3 days during the preproject period to 3.4 days during the 20-month sustainment period (P < .001). Non-VA care was completely eliminated for patients undergoing total hip and knee replacement at the Richard L. Roudebush Veterans Affairs Medical Center, producing an estimated return on investment of $1 million annually when compared with baseline cost and volumes. In addition, the volume of total joint replacements at this center increased during the data collection period. The success of the Joint Replacement Program demonstrates that VA-TAMMCS is an effective tool for Lean and Six Sigma process improvement initiatives in a surgical practice, producing a 36% sustained reduction in length of stay and completely eliminating non-VA care for total hip and knee replacements while increasing total joint replacement volume at this medical center.
Tagariello, G; De Biasi, E; Gajo, G B; Risato, R; Radossi, P; Davoli, P G; Traldi, A
2000-09-01
In this report we describe our experience of total hip replacement in two patients with severe haemophilia A and high titres of inhibitors to FVIII. We used rFVIIa replacement therapy by continuous infusion to perform the surgery. The total amount of rFVIIa used in these two patients was very similar but the manner of administration was quite different. In our experience, it is an advantage to use a higher dose for shorter periods than a lower dose for a longer treatment period. Tranexamic acid by continuous infusion, and parallel saline infusion were useful for good haemostasis and avoided local thrombophlebitis in the side of rFVIIa infusion.
Rahmann, Ann E; Brauer, Sandra G; Nitz, Jennifer C
2009-05-01
To evaluate the effect of inpatient aquatic physiotherapy in addition to usual ward physiotherapy on the recovery of strength, function, and gait speed after total hip or knee replacement surgery. Pragmatic randomized controlled trial with blinded 6-month follow-up. Acute-care private hospital. People (n=65) undergoing primary hip or knee arthroplasty (average age, 69.6+/-8.2y; 30 men). Participants were randomly assigned to receive supplementary inpatient physiotherapy, beginning on day 4: aquatic physiotherapy, nonspecific water exercise, or additional ward physiotherapy. Strength, gait speed, and functional ability at day 14. At day 14, hip abductor strength was significantly greater after aquatic physiotherapy intervention than additional ward treatment (P=.001) or water exercise (P=.011). No other outcome measures were significantly different at any time point in the trial, but relative differences favored the aquatic physiotherapy intervention at day 14. No adverse events occurred with early aquatic intervention. A specific inpatient aquatic physiotherapy program has a positive effect on early recovery of hip strength after joint replacement surgery. Further studies are required to confirm these findings. Our research indicates that aquatic physiotherapy can be safely considered in this early postoperative phase.
Healthcare Utilization and Costs of Knee or Hip Replacements versus Pain-Relief Injections
Pasquale, Margaret K.; Louder, Anthony M.; Cheung, Raymond Y.; Reiners, Andrew T.; Mardekian, Jack; Sanchez, Robert J.; Goli, Veerainder
2015-01-01
Background Given the dramatic increase in total knee and hip replacement procedures among the US population aged 45 years and older, there is a need to compare the downstream healthcare utilization and costs between patients who undergo joint replacement and those who receive intraarticular injections as a low-cost alternative. Objective To compare changes in osteoarthritis (OA)-related healthcare utilization and costs for Medicare members with OA who underwent knee or hip replacement versus those receiving steroid or viscosupplementation injections. Methods Medicare members aged ≥45 years diagnosed with OA were identified for this retrospective longitudinal study. Data were compared for patients who underwent primary knee or hip replacement surgery between July 1, 2007, and June 30, 2012, and those receiving injection of pain-relief medication during the same period. The date of joint replacement surgery was considered the index date. For the comparison cohort, the index date was 180 days postinjection of the first intraarticular injection. Medical and pharmacy claims were examined longitudinally in 90-day increments, from 180 days preindex until 360 days postindex. Difference-in-difference analyses were conducted to compare the change in OA-related healthcare costs, postindex versus preindex, between the study cohorts. Time-to-event analyses were used to measure rates of readmissions and venous thromboembolism (VTE). Results The mean age was 70.7 years for patients with knee replacement, 71.7 years for those with hip replacement, and 71.1 years for those receiving pain-relief injection (P <.0001). The RxRisk-V comorbidity index scores were 4.7, 4.4, and 4.8, respectively (P <.0001). Difference-in-difference analyses indicated that decreases in OA-related costs were greater for the joint replacement cohorts (coefficient for knee replacement*time: −0.603; hip replacement*time: −0.438; P <.001 for both) than for the comparison cohort. The VTE rates were 5.6% (knee) and 5.1% (hip) postsurgery versus 1.4% (knee) and 1.3% (hip) presurgery. Conclusion The overall difference-in-difference results showed a greater decrease in healthcare utilization and costs for the members with joint replacement than for those receiving injection. PMID:26557232
Complications of porous-coated press-fit cementless total hip replacement in dogs.
Kidd, Scott W; Preston, Christopher A; Moore, George E
2016-09-20
To report postoperative complications using a commercially available porous-coated press-fit cementless total hip replacement (THR) system in dogs. Medical records were reviewed for client-owned dogs with hip pathologies requiring THR. A minimum of six-week postoperative orthopaedic examination and orthogonal pelvic radiographs were used to assess outcome and complications in the perioperative period. Referring veterinarian medical records, phone interviews with clients, or both were used to assess long-term functional outcome and complications. Bilateral THR was performed in 36 dogs, and unilateral in 147 dogs, making a total of 219 THR procedures in 183 dogs. A total complication rate of 31.1% (68/219) was observed. A catastrophic complication was observed in 8.2% (n = 18), a major complication in 9.6% (n = 21), and a minor complication in 13.2% (n = 29) of procedures. The most common complications were intra-operative femoral fissure (n = 46), diaphyseal femoral fracture (n = 15), and coxofemoral luxation (n = 9). Full return to function was achieved in 88.1% of procedures with a median follow-up period of 42 months. Porous-coated press-fit cementless collarless total hip replacements have a high complication rate. The majority of complications occur intra-operatively or perioperatively, with few complications occurring beyond 12 weeks postoperatively. Both fissure fractures and diaphyseal femoral fractures carry a favourable prognosis with immediate cerclage wiring and plate fixation, respectively.
Piecuch, Wiesław; Sokołowska, Bozena; Dmoszyńska, Anna; Furmanik, Franciszek
2003-01-01
The aim of the study was to evaluate selected blood coagulation and fibrinolysis parameters in patients undergoing total hip replacement surgery with normovolemic hemodilution and standard enoksaparine profilaxis. The study included 66 patients undergoing hip replacement surgery. The group consisted of 51 women and 15 men, within the age range of 47-78, the mean age was 64. In 32 (subgroup II) patients the surgery was performed with the use of normovolemic hemodilution, in 34 (subgroup I) the hemodilution procedure was not applied. The enoksaparine as prophylaxis started 12 hours prior to surgery and continued during hospitalisation. The examination of the coagulation system was performed: on the day of the operation in the morning, on the day of the operation in the evening and on the first day after operation. We determined the concentrations of TAT and PAP complexes, prothrombin fragments 1 + 2 (F1 + 2) and d-dimers (DD). 1) during total hip replacement surgery and particularly in the period of the first 12 hours after the procedure marked activation of coagulation and fibrinolysis occurRed; 2) the application of the hemodilution procedure does not influence significantly the degree of coagulation and fibrinolysis disorders in the perioperative period, but could reduced incidence of thromboembolic complications in the postoperative period.
Dong, Jian-Bin; Wang, Zhi-Yong; Lu, Hao; Tian, Yuan; Wang, Xin-Rui; Zhang, Zhi-Qiang
2015-03-01
To compare the efficacy of internal fixation (including PFNA and PFN) versus hip replacement (including FHR or THA) in the treatment of trochanteric fractures in adults. Reports of studies using randomized controlled trials (RCT) to compare internal fixationg with hip replacement in the management of intertrochanteric fractures were retrieved (up to January 1, 2013) from the Cochrane Library, PUBMED Data, CNKI (China National Knowledge infrastructure), Elsevier, the Chinese Biomedical Database, Wanfang Data, and manually. Methodological quality of the trials was critically assessed, and relevant data were extracted. Statistical software RevMan 5.0 was used for data-analysis. Seven articles were included in the meta-analysis. The results showed that,compared internal fixation with hip replacement,there were statistical significance in the duration of surgery time [WMD = -2.66, 95% CI (-5.25,-0.06), P = 0.05], intra-operative blood loss [WMD = -24.20, 95% CI (-30.38, -18.02), P < 0.000 01], hospital stays time [WMD = -4.72, 95% CI (-5.18, -4.25), P < 0.000 01], bearing load time [WMD = -29.54, 95% CI (-30.77, -28.31), P < 0.000 01], total complications rate [WMD = 0.15, 95% CI (0.11, 0.22), P < 0.000 01], the good rate of Harris scores [WMD = 1.09, 95% CI (0.54,1.32), P < 0.05]. However, there were no statistical significance in the rate of deep venous thrombosis [WMD = 1.09, 95% CI (0.47, 2.55), P > 0.05]. CON- CLUSION: Hip replacement (containing FHR or THA) for the treatment of intertrochanteric fractures is superior to internal fixa- tion in regards to the duration of surgery time, the mean duration of hosipital stays, mean post-operative down time, intra-opera- tive blood loss, the rate of post-operative good Harris scores. But there is not enough evidence to show any difference between hip replacement (containing THA or FHR) and internal fixation in regards to the rate of deep venous thrombosis. However, internal fixation for the treatment of intertrochanteric fractures is superior to hip replacement (containing FHR or THA) in regards to total complications rate.
Qu, Zhijun; Wang, Geng; Xu, Chengshi; Zhang, Dazhi; Qu, Xiangdong; Zhou, Haibin; Ma, Jun
2016-10-01
Preoperative platelet rich plasma (PRP) harvest has been used in cardiopulmonary surgery for more than 10 years. There is no previous study dealing with PRP in bilateral total hip replacement. This study was to investigate the effects of PRP on blood saving and blood coagulation function in patients with bilateral total hip replacement. A prospective, randomized, clinical trial was conducted. Sixty patients were enrolled, including 30 patients undergoing PRP in the PRP group and 30 controls. The surgery time, total transfusion volume, blood loss, allogenic blood transfusion, autologous blood transfusion, urine volume, drainage volume, some blood parameters (including Fibrinogen, D-dimer, Prothrombin time, international normalizedratio, activated partial thromboplastin time, Platelet, Haemoglobin B), thrombelastogram (TEG) and blood-gas parameters were studied in the perioperative stage. The measurement data were analyzed statistically. There was no statistical difference between the two groups in baseline characteristics, surgery time, total transfusion volume, blood loss, autologous blood transfusion, etc. Allogenic blood transfusion in the PRP group was less than the control group with statistical difference (p = 0.024). Fibrinogen in the PRP group was higher than the control group (p = 0.008). Among the TEG indicators, activated clotting time and coagulation time K in the PRP group were less than the control group. Clotting rate and maximum amplitude in the PRP group were higher. The blood-gas parameters presented no statistical difference. The results suggested that PRP probably played a positive role in blood coagulation function as well as blood saving in patients with bilateral total hip replacement. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
Lassen, M R; Fisher, W; Mouret, P; Agnelli, G; George, D; Kakkar, A; Mismetti, P; Turpie, A G G
2012-05-01
Semuloparin is a novel ultra-low-molecular-weight heparin under development for venous thromboembolism (VTE) prevention in patients at increased risk, such as surgical and cancer patients. Three Phase III studies compared semuloparin and enoxaparin after major orthopedic surgery: elective knee replacement (SAVE-KNEE), elective hip replacement (SAVE-HIP1) and hip fracture surgery (SAVE-HIP2). All studies were multinational, randomized and double-blind. Semuloparin and enoxaparin were administered for 7-10 days after surgery. Mandatory bilateral venography was to be performed between days 7 and 11. The primary efficacy endpoint was a composite of any deep vein thrombosis, non-fatal pulmonary embolism or all-cause death. Safety outcomes included major bleeding, clinically relevant non-major (CRNM) bleeding, and any clinically relevant bleeding (major bleeding plus CRNM). In total, 1150, 2326 and 1003 patients were randomized in SAVE-KNEE, SAVE-HIP1 and SAVE-HIP2, respectively. In all studies, the incidences of the primary efficacy endpoint were numerically lower in the semuloparin group vs. the enoxaparin group, but the difference was statistically significant only in SAVE-HIP1. In SAVE-HIP1, clinically relevant bleeding and major bleeding were significantly lower in the semuloparin vs. the enoxaparin group. In SAVE-KNEE and SAVE-HIP2, clinically relevant bleeding tended to be higher in the semuloparin group, but rates of major bleeding were similar in the two groups. Other safety parameters were generally similar between treatment groups. Semuloparin was superior to enoxaparin for VTE prevention after hip replacement surgery, but failed to demonstrate superiority after knee replacement surgery and hip fracture surgery. Semuloparin and enoxaparin exhibited generally similar safety profiles. © 2012 International Society on Thrombosis and Haemostasis.
Adamkiewicz, Karolina; Płatek, Anna E; Łęgosz, Paweł; Czerniuk, Maciej R; Małdyk, Paweł; Szymański, Filip M
2018-01-01
Periodontal disease is a chronic disease causing an inflammatory process that affects various organs and is as-sociated with an increased risk of many diseases, including bone and cardiovascular disease. The aim of this study was to establish the prevalence of periodontal disease in continuous patients scheduled for hip or knee replacement surgery. The study was a prospective, epidemiological analysis performed in consecutive patients scheduled for total joint (hip or knee) replacement surgery. Patients enrolled into the study were screened for classical risk factors and had a dental evaluation performed for the diagnosis of periodontal disease. The study population consisted of 228 patients. A total of 137 (60.1%) patients were scheduled for a hip replace-ment surgery, while 91 (39.9%) had a knee replacement. The mean age of the study population was 66.8 ± 12.2 years, and 83 (36.4%) patients were male. A clinically significant disease was present in 65 (28.5%) cases, while all (100%) of the patients had at least minimal signs of periodontal disease. In patients with periodontal disease the percentage of tartar involvement of the teeth was 33.1 ± 26.8%, mean dental plaque coverage was 48.1 ± 29.8%, and bleeding occurred at a rate of 35.4 ± 29%. As for the hygiene level, it was generally poor in the majority of patients with periodontal disease. No differences in terms of baseline risk factors were present between patients with and without periodontal disease. In conclusion, periodontal diseases are highly prevalent in patients undergoing hip and/or knee replacement surgery. The presence of the periodontal disease is possibly associated with a worse prognosis and should be treated.
Revision total hip arthoplasty: factors associated with re-revision surgery.
Khatod, Monti; Cafri, Guy; Inacio, Maria C S; Schepps, Alan L; Paxton, Elizabeth W; Bini, Stefano A
2015-03-04
The survivorship of implants after revision total hip arthroplasty and risk factors associated with re-revision are not well defined. We evaluated the re-revision rate with use of the institutional total joint replacement registry. The purpose of this study was to determine patient, implant, and surgeon factors associated with re-revision total hip arthroplasty. A retrospective cohort study was conducted. The total joint replacement registry was used to identify patients who had undergone revision total hip arthroplasty for aseptic reasons from April 1, 2001, to December 31, 2010. The end point of interest was re-revision total hip arthroplasty. Risk factors evaluated for re-revision total hip arthroplasty included: patient risk factors (age, sex, body mass index, race, and general health status), implant risk factors (fixation type, bearing surface, femoral head size, and component replacement), and surgeon risk factors (volume and experience). A multivariable Cox proportional hazards model was used. Six hundred and twenty-nine revision total hip arthroplasties with sixty-three (10%) re-revisions were evaluated. The mean cohort age (and standard deviation) was 57.0 ± 12.4 years, the mean body mass index (and standard deviation) was 29.5 ± 6.1 kg/m(2), and most of the patients were women (64.5%) and white (81.9%) and had an American Society of Anesthesiologists score of <3 (52.9%). The five-year implant survival after revision total hip arthroplasty was 86.8% (95% confidence interval, 83.57% to 90.25%). In adjusted models, age, total number of revision surgical procedures performed by the surgeon, fixation, and bearing surface were associated with the risk of re-revision. For every ten-year increase in patient age, the hazard ratio for re-revision decreases by a factor of 0.72 (95% confidence interval, 0.58 to 0.90). For every five revision surgical procedures performed by a surgeon, the risk of revision decreases by a factor of 0.93 (95% confidence interval, 0.86 to 0.99). At the time of revision, a new or retained cemented femoral implant or all-cemented hip implant increases the risk of revision by a factor of 3.19 (95% confidence interval, 1.22 to 8.38) relative to a retained or new uncemented hip implant. A ceramic on a highly cross-linked polyethylene bearing articulation decreases the hazard relative to metal on highly cross-linked polyethylene by a factor of 0.32 (95% confidence interval, 0.11 to 0.95). Metal on constrained bearing increases the hazard relative to metal on highly cross-linked polyethylene by a factor of 3.32 (95% confidence interval, 1.16 to 9.48). When evaluating patient, implant, and surgical factors at the time of revision total hip arthroplasty, age, surgeon experience, implant fixation, and bearing surfaces had significant impacts on the risk of re-revision. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.
Chess, David G.; Grainger, R. Wayne; Phillips, Tom; Zarzour, Zane D.; Sheppard, Bruce R.
1996-01-01
Objective To review the clinical performance of the anatomic medullary locking (AML) femoral stem in total hip arthroplasty. Design A clinical and radiographic review. Setting A tertiary lower limb joint replacement centre. Patients Two hundred and twenty-one patients with noninflammatory gonarthrosis. Interventions Two hundred and twenty-seven primary total hip arthroplasties with the noncemented AML component completed by two surgeons. Main Outcome Measures Independent review by two experienced reviewers of the postoperative Harris hip score, radiographs of component fixation, size and degree of diaphyseal fill. Results Harris hip score was 84 (range from 43 to 98); component fixation showed bone ingrowth in 41%, stable fixation with fibrous ingrowth in 56% and unstable fixation in 3%; severe thigh pain in 4% of cases correlated with unstable fixation, and there was mild thigh pain in 20% of cases. Conclusion The AML femoral stem performs well in replacement arthroplasty compared with other noncemented stems. PMID:8857987
[Short-term curative effects of Tantalum rod treatment in early avascular necrosis].
Ye, Fu-Sheng; Ni, Zhe-Ji; Chu, Xiao-Bing; He, Bang-Jian; Li, Ju; Tong, Pei-Jian
2013-08-01
To explore the recent clinical curative effect of Tantalum rod in treating the early avascular necrosis. From January 2008 to November 2008, the 25 patients (39 hips) with early avascular necrosis accepted tantalum rod placement and included 9 males (11 hips) and 16 females (28 hips) with an average age of 37 years old ranging from 18 to 74 years old. Four patients (6 hips) caused by Alcoholic, 6 patients (8 hips) by hormone, 2 cases (2 hips) by traumatic, 13 cases (23 hips) by idiopathic. Steinberg preoperative stage involved 7 hips in period I, 24 hips in period II, 8 hips in period III. Curative effect analysis included preoperative and postoperative Harris score, radiographic changes and hip replacement for follow-up to accept the end of the femoral head survival rate. All patients were followed up for 6 to 47 months (averaged 37.4 months). All 12 hips imaging appeard progress,including tantalum rod exit in 1 hip, hip hemiarthroplasty collapse in 3 hips, the area increased to avascular necrosis in 8 hips. Six hips accepted total hip replacement, including imaging progress in 5 hips (41.7%, 5/12), no imaging progress in 1 hip (3.7%,1/27). All hips' Kaplan-Meier survival curves showed 6-month survival rate was (97.4 +/- 2.5)% after tantalum stick insertion, 1-year survival rate was (94.7 +/- 3.6), and 2-year survival rate was (88.6 +/- 5.4)%, 3-year survival rate was (72.5 +/- 11.2). It is effective for treatment of avascular necrosis of femoral head in Steinberg I and II by Tantalum rod, and it can effectively relieve femoral head replacement time.
Accuracy of femoral templating in reproducing anatomical femoral offset in total hip replacement.
Davies, H; Foote, J; Spencer, R F
2007-01-01
Restoration of hip biomechanics is a crucial component of successful total hip replacement. Preoperative templating is recommended to ensure that the size and orientation of implants is optimised. We studied how closely natural femoral offset could be reproduced using the manufacturers' templates for 10 femoral stems in common use in the UK. A series of 23 consecutive preoperative radiographs from patients who had undergone unilateral total hip replacement for unilateral osteoarthritis of the hip was employed. The change in offset between the templated position of the best-fitting template and the anatomical centre of the hip was measured. The templates were then ranked according to their ability to reproduce the normal anatomical offset. The most accurate was the CPS-Plus (Root Mean Square Error 2.0 mm) followed in rank order by: C stem (2.16), CPT (2.40), Exeter (3.23), Stanmore (3.28), Charnley (3.65), Corail (3.72), ABG II (4.30), Furlong HAC (5.08) and Furlong modular (7.14). A similar pattern of results was achieved when the standard error of variability of offset was analysed. We observed a wide variation in the ability of the femoral prosthesis templates to reproduce normal femoral offset. This variation was independent of the seniority of the observer. The templates of modern polished tapered stems with high modularity were best able to reproduce femoral offset. The current move towards digitisation of X-rays may offer manufacturers an opportunity to improve template designs in certain instances, and to develop appropriate computer software.
Bilateral total hip arthroplasty in Morquio-Brailsford's syndrome: a report of two cases.
Tassinari, Enrico; Boriani, Luca; Traina, Francesco; Dallari, Dante; Toni, Aldo; Giunti, Armando
2008-09-01
We report two cases of bilateral cementless total hip arthroplasty in two young women affected by Morquio-Brailsford syndrome. Morquio-Brailsford disease belongs to the mucopolysaccharidoses; it shows growth retardation with disproportional dwarfism. Usually patients are affected by a severe joint degeneration from their 2nd or 3rd decade. Young age, severe dysplasia, and joint size are the main technical problems for a total hip replacement. Accurate radiographic and CT planning allows the use of standard prostheses instead of custom-made ones.
2017-06-23
Rheumatoid Arthritis; Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis
2017-06-23
Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis
Fabio, Costa; Romualdo, Del Buono; Eugenio, Agrò Felice; Vittoradolfo, Tambone; Massimiliano, Vitali Andrea; Giovanna, Ricci
2017-01-01
Spinal anaesthesia is the most preffered anesthesia technique for total hip replacement, and its complications range from low entity (insignificant) to life threatening. The incidence of neurologic complications after neuraxial anaesthesia is not perfectly clear, although there are several described cases of spinal cord ischaemia. We present a case of unilateral T8–T11 spinal cord ischaemia following L2–L3 spinal anaesthesia for total hip replacement. Magnetic resonance imaging showed a hyperintense T8–T11 signal alteration on the leftside of paramedian spinal cord. A temporal epidemiologic linkage between the damage and the surgery seems to be present. The injury occurred without anatomical proximity between the injury site and the spinal needle entry site. This may be due to multiple contributing factors, each of them is probably not enough to determine the damage by itself; however, acting simultaneously, they could have been responsible for the complication. The result was unpredictable and unavoidable and was caused by unforeseeable circumstances and not by inadequate medical practice. PMID:28439446
The Benefit of Modified Rehabilitation and Minimally Invasive Techniques in Total Hip Replacement
Lilikakis, Anastasios K; Gillespie, Beryl; Villar, Richard N
2008-01-01
INTRODUCTION We wished to assess if an intensive rehabilitation regimen alone, or one combined with modified anaesthetic and surgical techniques, can change the speed of rehabilitation or the length of hospital stay after total hip replacement. PATIENTS AND METHODS We compared 44 patients who had followed a traditional care pathway, with 38 patients who had rehabilitated under a new rehabilitation protocol, with 40 patients who had also received modified, minimally invasive techniques. The speed of rehabilitation was measured in terms of three specific milestones accomplished on the day after surgery. RESULTS We found a statistically significant improvement in the day after surgery each activity was possible. The length of hospital stay was reduced from 6.5 days to 5.4 days to 4.1 days, a difference which was also statistically significant. CONCLUSIONS The data support the view that a new rehabilitation protocol alone can reduce the length of hospital stay and hasten rehabilitation. The combination of modified anaesthetic and minimally invasive surgical techniques with the new rehabilitation regimen can further improve short-term outcome after total hip replacement. PMID:18634739
MRSA-infected external iliac artery pseudoaneurysm treated with endovascular stenting.
Clarke, M G; Thomas, H G; Chester, J F
2005-01-01
A 48-year-old woman with severe juvenile-onset rheumatoid arthritis presented with a bleeding cutaneous sinus distal to her right total hip replacement scar. Methicillin resistant Staphylococcus aureus (MRSA) was isolated on culture. She had previously undergone bilateral total hip and knee replacements at aged 23 and six years later had the right knee prosthesis removed for infection, with subsequent osteomyelitis of the femoral shaft and right total hip prosthesis disruption. Peripheral arteriography was performed in view of persistent bleeding from the sinus, which revealed a 6 cm false aneurysm filling from and compressing the right external iliac artery (EIA). A PTFE-covered, balloon expandable JOSTENT was deployed in the right EIA, successfully excluding the false aneurysm and preventing further bleeding from the sinus. No graft infection was reported at 12 months. This case illustrates the potential use of endovascular stent-grafting in the treatment of an infected pseudoaneurysm.
MRSA-Infected External Iliac Artery Pseudoaneurysm Treated with Endovascular Stenting
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clarke, M.G.; Thomas, H.G.; Chester, J.F.
2005-04-15
A 48-year-old woman with severe juvenile-onset rheumatoid arthritis presented with a bleeding cutaneous sinus distal to her right total hip replacement scar. Methicillin resistant Staphylococcus aureus (MRSA) was isolated on culture. She had previously undergone bilateral total hip and knee replacements at aged 23 and six years later had the right knee prosthesis removed for infection, with subsequent osteomyelitis of the femoral shaft and right total hip prosthesis disruption. Peripheral arteriography was performed in view of persistent bleeding from the sinus, which revealed a 6 cm false aneurysm filling from and compressing the right external iliac artery (EIA). A PTFE-covered,more » balloon expandable JOSTENT was deployed in the right EIA, successfully excluding the false aneurysm and preventing further bleeding from the sinus. No graft infection was reported at 12 months. This case illustrates the potential use of endovascular stent-grafting in the treatment of an infected pseudoaneurysm.« less
Hip or knee replacement - after - what to ask your doctor
... chap 7. Read More Hip joint replacement Hip pain Knee joint replacement Knee pain Osteoarthritis Patient Instructions Getting your home ready - knee or hip surgery Hip or knee replacement - before - ...
Hip or knee replacement - before - what to ask your doctor
... chap 7. Read More Hip joint replacement Hip pain Knee joint replacement Knee pain Osteoarthritis Patient Instructions Getting your home ready - knee or hip surgery Hip or knee replacement - after - ...
2016-05-09
Osteoarthritis; Post-traumatic Arthritis; Collagen Disorder; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis
2017-03-02
Rheumatoid Arthritis; Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis
2016-10-06
Rheumatoid Arthritis; Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis
2017-06-27
Rheumatoid Arthritis; Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis
2016-10-06
Rheumatoid Arthritis; Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis
Shaparin, Naum; Widyn, James; Nair, Singh; Kho, Irene; Geller, David; Delphin, Ellise
2016-08-01
There is evidence that very obese patients (body mass index [BMI] >40 kg/m(2)) undergoing hip replacement have longer average hospital stays, as well as higher rates of complications and readmission compared with patients with normal BMI. However, there are sparse data describing how overweight and obese patients fare in the period immediately after hip replacement surgery compared with patients with low or normal BMI. In this study, we sought to explore the association of BMI with the rate of early postoperative complications in patients undergoing total hip arthroplasty. A proprietary hospital software program, Clinical Looking Glass was used to query the Montefiore Medical Center database and create a list of patients with International Classification of Diseases, Ninth Revision code 81.51 (hip replacement) from the period of January 1, 2010, through December 31, 2012. The medical records of patients with length of stay 5 or more days were reviewed to evaluate the reason for the extended stay. The primary outcome studied was the association between BMI and occurrence of early complications in patients who had undergone total hip replacement surgery. Logistic regression was used to calculate adjusted odds ratio (OR) and 95% confidence interval (CI) for the association of BMI and early postoperative complications. Of the 802 patients undergoing hip replacement surgery within our time frame, 142 patient medical records were reviewed due to their length of stay of ≥5 days. Overall complication rate in the analyzed patients demonstrated a J-curve distribution pattern, with the highest morbidity being 23.5% in the underweight group, the second highest in the normal-weight group (17.3%), and decreasing to nadir in the overweight (8.0%) and obese class I (10.0%) and then higher again in classes II (14.3%) and III (16.7%). Adjusted ORs demonstrated the same J distribution pattern similar to the pattern observed in the univariate analysis. Of the variables studied, Charlson score (OR, 1.1; 95% CI, 1.1-1.2; P = .03), diagnosis of hip fracture (OR, 5.2; 95% CI, 2.8-9.8; P = .01), normal weight (OR, 1.9; 95% CI, 1.1-3.8; P = .04), and obese class III (OR, 2.5; 95% CI, 1.1-6.3; P = .04) were the factors associated with the highest odds of early complications after hip replacement surgery. In this retrospective review of hip replacement surgery patients, BMI classification was a predictor of early postoperative complications. Although the exact underlying mechanisms are still not clear, these results are consistent with the obesity paradox, in which obesity or its correlates provide some form of protection. Copyright © 2016 Elsevier Inc. All rights reserved.
Enhanced recovery in total hip replacement: a clinical review.
Ibrahim, M S; Twaij, H; Giebaly, D E; Nizam, I; Haddad, F S
2013-12-01
The outcome after total hip replacement has improved with the development of surgical techniques, better pain management and the introduction of enhanced recovery pathways. These pathways require a multidisciplinary team to manage pre-operative education, multimodal pain control and accelerated rehabilitation. The current economic climate and restricted budgets favour brief hospitalisation while minimising costs. This has put considerable pressure on hospitals to combine excellent results, early functional recovery and shorter admissions. In this review we present an evidence-based summary of some common interventions and methods, including pre-operative patient education, pre-emptive analgesia, local infiltration analgesia, pre-operative nutrition, the use of pulsed electromagnetic fields, peri-operative rehabilitation, wound dressings, different surgical techniques, minimally invasive surgery and fast-track joint replacement units.
Time-based analysis of total cost of patient episodes: a case study of hip replacement.
Peltokorpi, Antti; Kujala, Jaakko
2006-01-01
Healthcare in the public and private sectors is facing increasing pressure to become more cost-effective. Time-based competition and work-in-progress have been used successfully to measure and improve the efficiency of industrial manufacturing. Seeks to address this issue. Presents a framework for time based management of the total cost of a patient episode and apply it to the six sigma DMAIC-process development approach. The framework is used to analyse hip replacement patient episodes in Päijät-Häme Hospital District in Finland, which has a catchment area of 210,000 inhabitants and performs an average of 230 hip replacements per year. The work-in-progress concept is applicable to healthcare--notably that the DMAIC-process development approach can be used to analyse the total cost of patient episodes. Concludes that a framework, which combines the patient-in-process and the DMAIC development approach, can be used not only to analyse the total cost of patient episode but also to improve patient process efficiency. Presents a framework that combines patient-in-process and DMAIC-process development approaches, which can be used to analyse the total cost of a patient episode in order to improve patient process efficiency.
Munin, Michael C; Putman, Koen; Hsieh, Ching-Hui; Smout, Randall J; Tian, Wenqiang; DeJong, Gerben; Horn, Susan D
2010-07-01
To characterize rehabilitation services in two types of postacute facilities in patients who underwent hip replacement following a hip fracture. Multisite prospective observational cohort from 6 freestanding skilled nursing facilities and 11 inpatient rehabilitation facilities. Patients (n = 218) with hip fracture who had either hemiarthroplasty or total hip arthroplasty followed by rehabilitation at skilled nursing facilities or inpatient rehabilitation facilities were enrolled. Using a point-of-care methodology, we recorded data from actual physical therapy and occupational therapy sessions completed including functional outcomes during the postacute admission. Onset time from surgical repair to rehabilitation admission was not significantly different between sites. Average skilled nursing facilities length of stay was 24.7 +/- 13.6 days, whereas inpatient rehabilitation facilities was 13.0 +/- 5.7 days (P < 0.01). Total hours of physical therapy and occupational therapy services per patient day were 1.2 in skilled nursing facilities and 2.0 in inpatient rehabilitation facilities. For weekdays only, these data changed to 1.6 in skilled nursing facilities and 2.6 hrs per patient in inpatient rehabilitation facilities (P < 0.01). Patients in inpatient rehabilitation facilities accrued more time for gait training and exercise in physical therapy, which was found to be 48% and 40% greater, respectively, through day 8. In occupational therapy, patients of inpatient rehabilitation facilities had more time allocated to lower body dressing and transfers. Significant differences in rehabilitation activities were observed, and intensity was notably different within the first 8 therapy days even though baseline demographics and medical complexity were comparable across facility types. Our data suggest that after more complex hip replacement surgery, hip fracture patients can tolerate more intensive therapy earlier within the rehabilitation program.
Prospective monitoring improves outcomes of primary total hip replacement: a cohort study
Streubel, Philipp N; Pachón, Marcela; Kerguelén, Carlos A; Navas, José; Portocarrero, Julio; Pesantez, Rodrigo F; Zayed, Gamal; Carrillo, Germán; Llinás, Adolfo M
2009-01-01
Background Over the past decade several studies have questioned current standards of patient safety in health care delivery. In response, our institution started a clinical pathway for total hip replacement in 1996. Prospective monitoring with regular feedback sessions to the individuals involved in patient care did however not start until 2003. The present study evaluates the effect of prospective monitoring on outcomes of total hip replacement. Methods Clinical records of patients undergoing primary elective total hip replacement between 1997 and 2004 were reviewed. Data on adverse events as well as adherence to protocols for venous thromboembolism prophylaxis were extracted retrospectively for the period 1997 to 2001 and prospectively from 2003 to 2004. Results were compared and analyzed in order to establish possible improvement in outcomes. Data was analyzed with Chi-square or Fisher's Exact test for categorical variables and Student's t-test for continuous variables. Alpha was set as less than 5% and analysis was performed with Stata 9.0 for Macintosh. Results Two-hundred and eighty-three patients were included from 1997 to 2001, and 62 from 2003 to 2004. Mean age, male to female ratio and initial diagnosis were similar in both groups. At least one adverse event occurred in 45% of patients in 1997–2001 and in 21% in 2003–2004 (p < 0.001). In-hospital hip dislocations occurred in 6% and 0% (p = 0.05), oliguria in 19% and 5% (p = 0.007), SSI and VTE in 3% and 0% (p = 0.37), adverse drug reactions in 11% and 13% (p = 0.66) and non-adherence to VTE prophylaxis protocols in 15% and 2% of cases respectively (p = 0.002). Conclusion Overall rate of adverse events as well as in-hospital hip dislocations, oliguria and non-adherence to VTE prophylaxis protocols were significantly reduced during the second period. We conclude that clinical pathways alone are insufficient to improve patient safety and require prospective monitoring and continuous feedback to health care providers in order to achieve the desired effect. PMID:19366438
Lessons learned from study of congenital hip disease in adults.
Hartofilakidis, George; Lampropoulou-Adamidou, Kalliopi
2016-12-18
Orthopaedic surgeons specialising in adult hip reconstruction surgery often face the problem of osteoarthritis secondary to congenital hip disease (CHD). To achieve better communication among physicians, better treatment planning and evaluation of the results of various treatment options, an agreed terminology is needed to describe the entire pathology. Furthermore, a generally accepted classification of the deformities is necessary. Herein, the authors propose the use of the term "congenital hip disease" and its classification as dysplasia, low dislocation and high dislocation. Knowledge of the CHD natural history facilitates comprehension of the potential development and progression of the disease, which differs among the aforementioned types. This can lead to better understanding of the anatomical abnormalities found in the different CHD types and thus facilitate preoperative planning and choice of the most appropriate management for adult patients. The basic principles for improved results of total hip replacement in patients with CHD, especially those with low and high dislocation, are: Wide exposure, restoration of the normal centre of rotation and the use of special techniques and implants for the reconstruction of the acetabulum and femur. Application of these principles during total hip replacement in young female patients born with severe deformities of the hip joint has led to radical improvement of their quality of life.
Nieuwenhuijse, Marc J; Nelissen, R G H H; Schoones, J W; Sedrakyan, A
2014-09-09
To determine the evidence of effectiveness and safety for introduction of five recent and ostensibly high value implantable devices in major joint replacement to illustrate the need for change and inform guidance on evidence based introduction of new implants into healthcare. Systematic review of clinical trials, comparative observational studies, and registries for comparative effectiveness and safety of five implantable device innovations. PubMed (Medline), Embase, Web of Science, Cochrane, CINAHL, reference lists of articles, annual reports of major registries, summaries of safety and effectiveness for pre-market application and mandated post-market studies at the US Food and Drug Administration. The five selected innovations comprised three in total hip replacement (ceramic-on-ceramic bearings, modular femoral necks, and uncemented monoblock cups) and two in total knee replacement (high flexion knee replacement and gender specific knee replacement). All clinical studies of primary total hip or knee replacement for symptomatic osteoarthritis in adults that compared at least one of the clinical outcomes of interest (patient centred outcomes or complications, or both) in the new implant group and control implant group were considered. Data searching, abstraction, and analysis were independently performed and confirmed by at least two authors. Quantitative data syntheses were performed when feasible. After assessment of 10,557 search hits, 118 studies (94 unique study cohorts) met the inclusion criteria and reported data related to 15,384 implants in 13,164 patients. Comparative evidence per device innovation varied from four low to moderate quality retrospective studies (modular femoral necks) to 56 studies of varying quality including seven high quality (randomised) studies (high flexion knee replacement). None of the five device innovations was found to improve functional or patient reported outcomes. National registries reported two to 12 year follow-up for revision occurrence related to more than 200,000 of these implants. Reported comparative data with well established alternative devices (over 1,200,000 implants) did not show improved device survival. Moreover, we found higher revision occurrence associated with modular femoral necks (hazard ratio 1.9) and ceramic-on-ceramic bearings (hazard ratio 1.0-1.6) in hip replacement and with high flexion knee implants (hazard ratio 1.0-1.8). We did not find convincing high quality evidence supporting the use of five substantial, well known, and already implemented device innovations in orthopaedics. Moreover, existing devices may be safer to use in total hip or knee replacement. Improved regulation and professional society oversight are necessary to prevent patients from being further exposed to these and future innovations introduced without proper evidence of improved clinical efficacy and safety. © Nieuwenhuijse et al 2014.
Nieuwenhuijse, Marc J; Nelissen, R G H H; Schoones, J W
2014-01-01
Objective To determine the evidence of effectiveness and safety for introduction of five recent and ostensibly high value implantable devices in major joint replacement to illustrate the need for change and inform guidance on evidence based introduction of new implants into healthcare. Design Systematic review of clinical trials, comparative observational studies, and registries for comparative effectiveness and safety of five implantable device innovations. Data sources PubMed (Medline), Embase, Web of Science, Cochrane, CINAHL, reference lists of articles, annual reports of major registries, summaries of safety and effectiveness for pre-market application and mandated post-market studies at the US Food and Drug Administration. Study selection The five selected innovations comprised three in total hip replacement (ceramic-on-ceramic bearings, modular femoral necks, and uncemented monoblock cups) and two in total knee replacement (high flexion knee replacement and gender specific knee replacement). All clinical studies of primary total hip or knee replacement for symptomatic osteoarthritis in adults that compared at least one of the clinical outcomes of interest (patient centred outcomes or complications, or both) in the new implant group and control implant group were considered. Data searching, abstraction, and analysis were independently performed and confirmed by at least two authors. Quantitative data syntheses were performed when feasible. Results After assessment of 10 557 search hits, 118 studies (94 unique study cohorts) met the inclusion criteria and reported data related to 15 384 implants in 13 164 patients. Comparative evidence per device innovation varied from four low to moderate quality retrospective studies (modular femoral necks) to 56 studies of varying quality including seven high quality (randomised) studies (high flexion knee replacement). None of the five device innovations was found to improve functional or patient reported outcomes. National registries reported two to 12 year follow-up for revision occurrence related to more than 200 000 of these implants. Reported comparative data with well established alternative devices (over 1 200 000 implants) did not show improved device survival. Moreover, we found higher revision occurrence associated with modular femoral necks (hazard ratio 1.9) and ceramic-on-ceramic bearings (hazard ratio 1.0-1.6) in hip replacement and with high flexion knee implants (hazard ratio 1.0-1.8). Conclusion We did not find convincing high quality evidence supporting the use of five substantial, well known, and already implemented device innovations in orthopaedics. Moreover, existing devices may be safer to use in total hip or knee replacement. Improved regulation and professional society oversight are necessary to prevent patients from being further exposed to these and future innovations introduced without proper evidence of improved clinical efficacy and safety. PMID:25208953
Donauer, Katharina; Bomberg, Hagen; Wagenpfeil, Stefan; Volk, Thomas; Meissner, Winfried; Wolf, Alexander
2018-05-14
Total hip and knee replacements are common surgeries, and an optimal pain treatment is essential for early rehabilitation. Since data from randomized controlled trails on the use of regional anesthesia in joint replacements of the lower extremities are conflicting, we analyzed the international PAIN OUT registry for comparison of regional anesthesia vs. general anesthesia regarding pain and morphine consumption on the first postoperative day. International Classification of Diseases-9 (ICD-9) codes were used to identify 2,346 cases for knee and 2,315 for hip arthroplasty between 2010 and 2016 from the PAIN OUT registry. Those were grouped according to anesthesia provided (general, regional, and a combination of both). At the first day after surgery, pain levels and opioid consumption was compared. Adjusted odds ratios (aOR [95% CI]) were calculated with logistic regression and propensity matching was used as a sensitivity analysis. After adjustment for confounders, regional anesthesia was associated with reduced opioid consumption (0.20 [0.13-0.30], p<0.001) and less pain (0.53 [0.36-0.78], p=0.001) than general anesthesia in knee surgery. In hip surgery, regional anesthesia was only associated with reduced opioid consumption (0.17 [0.11-0.26], p<0.001), whereas pain was comparable (1.23 [0.94-1.61], p=0.1). Results from a propensity-matched sensitivity analysis were similar. In total knee arthroplasty, regional anesthesia was associated with less pain and lower opioid consumption. In total hip arthroplasty, regional anesthesia was associated with a lower opioid consumption, however not with reduced pain levels. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Hua, Xijin; Li, Junyan; Wang, Ling; Jin, Zhongmin; Wilcox, Ruth; Fisher, John
2014-01-01
Edge loading can negatively impact the biomechanics and long-term performance of hip replacements. Although edge loading has been widely investigated for hard-on-hard articulations, limited work has been conducted for hard-on-soft combinations. The aim of the present study was to investigate edge loading and its effect on the contact mechanics of a modular metal-on-polyethylene (MoP) total hip replacement (THR). A three-dimensional finite element model was developed based on a modular MoP bearing. Different cup inclination angles and head lateral microseparation were modelled and their effect on the contact mechanics of the modular MoP hip replacement were examined. The results showed that lateral microseparation caused loading of the head on the rim of the cup, which produced substantial increases in the maximum von Mises stress in the polyethylene liner and the maximum contact pressure on both the articulating surface and backside surface of the liner. Plastic deformation of the liner was observed under both standard conditions and microseparation conditions, however, the maximum equivalent plastic strain in the liner under microseparation conditions of 2000 µm was predicted to be approximately six times that under standard conditions. The study has indicated that correct positioning the components to avoid edge loading is likely to be important clinically even for hard-on-soft bearings for THR. PMID:25218504
Kim, Y-H
2008-03-01
This study reviewed the results of a cementless anatomical femoral component to give immediate post-operative stability, and with a narrow distal section in order not to contact the femoral cortex in the diaphysis, ensuring exclusively metaphyseal loading. A total of 471 patients (601 hips) who had a total hip replacement between March 1995 and February 2002 were included in the study. There were 297 men and 174 women. The mean age at the time of operation was 52.7 years (28 to 63). Clinical and radiological evaluation were performed at each follow-up. Bone densitometry was carried out on all patients two weeks after operation and at the final follow-up examination. The mean follow-up was 8.8 years (5 to 12). The mean pre-operative Harris hip score was 41 points (16 to 54), which improved to a mean of 96 (68 to 100) at the final follow-up. No patient complained of thigh pain at any stage. No acetabular or femoral osteolysis was observed and no hip required revision for aseptic loosening of either component. Deep infection occurred in two hips (0.3%) which required revision. One hip (0.2%) required revision of the acetabular component for recurrent dislocation. Bone mineral densitometry revealed a minimal bone loss in the proximal femur. This cementless anatomical femoral component with metaphyseal loading but without distal fixation produced satisfactory fixation and encourages proximal femoral loading.
Radl, R; Aigner, C; Hungerford, M; Pascher, A; Windhager, R
2000-11-01
We performed a retrospective analysis of the clinical and radiological outcomes of total hip replacement using an uncemented femoral component proximally coated with hydroxyapatite. Of 136 patients, 118 who had undergone 124 primary total hip replacements were available for study. Their mean age was 66.5 years (19 to 90) and the mean follow-up was 5.6 years (4.25 to 7.25). At the final follow-up the mean Harris hip score was 92 (47.7 to 100). Periprosthetic femoral fractures, which occurred in seven patients (5.6%), were treated by osteosynthesis in six and conservatively in one. We had to revise five femoral components, one because of aseptic loosening, one because of septic loosening and three because of periprosthetic fracture. At the final follow-up there were definite signs of aseptic loosening in two patients. Radiologically, proximal femoral bone loss in Gruen zones I and VI was evident in 96.8% of hips, while bone hypertrophy in zones III and V was seen in 64.7%. In 24 hips (20.2%) the mean subsidence of the stem was 3.7 mm which occurred within the first 12 postoperative weeks. This indicated poor initial stability, which might have been aggravated by early weight-bearing. The high rate of failure in our study suggests that proximal femoral bone loss affects the long-term survival of the replacement.
Spine–hip relations in patients with hip osteoarthritis
Rivière, Charles; Lazic, Stefan; Dagneaux, Louis; Van Der Straeten, Catherine; Cobb, Justin; Muirhead-Allwood, Sarah
2018-01-01
Patients with hip osteoarthritis often have an abnormal spine-hip relation (SHR), meaning the presence of a clinically deleterious spine-hip and/or hip-spine syndrome. Definition of the individual SHR is ideally done using the EOS® imaging system or, if not available, with conventional lumbopelvic lateral radiographs. By pre-operatively screening patients with abnormal SHR, it is possible to refine total hip replacement (THR) surgical planning, which may improve outcomes. An important component of the concept of kinematically aligned total hip arthroplasty (KA THA) consists of defining the optimal acetabular cup design and orientation based on the assessment of an individual’s SHR, and use of the transverse acetabular ligament to adjust the cup positioning. The Bordeaux classification might advance the understanding of SHR and hopefully help improve THR outcomes. Cite this article: EFORT Open Rev 2018;3:39-44. DOI: 10.1302/2058-5241.3.170020 PMID:29657844
Knee and Ankle Arthroplasty in Hemophilia
Solimeno, Luigi Piero; Pasta, Gianluigi
2017-01-01
Today, major surgical procedures can be safely performed in hemophilic patients with chronic arthropathy, using available factor concentrates. In this setting, total knee replacement is considered the “gold standard”, while the use of total ankle replacement is still debated. Indeed, the unsatisfactory results obtained with the previous available design of implants did not raise enthusiasm as knee or hip replacement. Recently, the introduction of new implant designs and better reported outcomes have renewed the interest in total ankle replacement in people with hemophilia. In this review, the role of replacement surgery in the treatment of chronic hemophilic arthropathy will be described. PMID:29165342
Part II: managing perioperative hyperglycemia in total hip and knee replacement surgeries.
Agos, Florence; Shoda, Casey; Bransford, Deborah
2014-09-01
Perioperative hyperglycemia management is an important factor in reducing the risk of surgical site infections (SSIs) in all patients regardless of existing history of diabetes. Reduction of SSIs is one of the quality indicators reported by the National Healthcare Safety Networks of the Centers for Disease Control and Prevention (CDC). In 2009 and 2010, the orthopedic surgical unit had an increased number of SSIs above the CDC benchmark. This article describes the impact of an evidence-based practice standard for perioperative hyperglycemia management in the reduction of SSIs in patients having total hip and knee replacement surgery. Copyright © 2014 Elsevier Inc. All rights reserved.
Eichler, Sarah; Rabe, Sophie; Salzwedel, Annett; Müller, Steffen; Stoll, Josefine; Tilgner, Nina; John, Michael; Wegscheider, Karl; Mayer, Frank; Völler, Heinz
2017-09-21
Total hip or knee replacement is one of the most frequently performed surgical procedures. Physical rehabilitation following total hip or knee replacement is an essential part of the therapy to improve functional outcomes and quality of life. After discharge from inpatient rehabilitation, a subsequent postoperative exercise therapy is needed to maintain functional mobility. Telerehabilitation may be a potential innovative treatment approach. We aim to investigate the superiority of an interactive telerehabilitation intervention for patients after total hip or knee replacement, in comparison to usual care, regarding physical performance, functional mobility, quality of life and pain. This is an open, randomized controlled, multicenter superiority study with two prospective arms. One hundred and ten eligible and consenting participants with total knee or hip replacement will be recruited at admission to subsequent inpatient rehabilitation. After comprehensive, 3-week, inpatient rehabilitation, the intervention group performs a 3-month, interactive, home-based exercise training with a telerehabilitation system. For this purpose, the physiotherapist creates an individual training plan out of 38 different strength and balance exercises which were implemented in the system. Data about the quality and frequency of training are transmitted to the physiotherapist for further adjustment. Communication between patient and physiotherapist is possible with the system. The control group receives voluntary, usual aftercare programs. Baseline assessments are investigated after discharge from rehabilitation; final assessments 3 months later. The primary outcome is the difference in improvement between intervention and control group in 6-minute walk distance after 3 months. Secondary outcomes include differences in the Timed Up and Go Test, the Five-Times-Sit-to-Stand Test, the Stair Ascend Test, the Short-Form 36, the Western Ontario and McMaster Universities Osteoarthritis Index, the International Physical Activity Questionnaire, and postural control as well as gait and kinematic parameters of the lower limbs. Baseline-adjusted analysis of covariance models will be used to test for group differences in the primary and secondary endpoints. We expect the intervention group to benefit from the interactive, home-based exercise training in many respects represented by the study endpoints. If successful, this approach could be used to enhance the access to aftercare programs, especially in structurally weak areas. German Clinical Trials Register (DRKS), ID: DRKS00010009 . Registered on 11 May 2016.
MRI Evaluation of Post Core Decompression Changes in Avascular Necrosis of Hip.
Nori, Madhavi; Marupaka, Sravan Kumar; Alluri, Swathi; Md, Naseeruddin; Irfan, Kazi Amir; Jampala, Venkateshwarlu; Apsingi, Sunil; Eachempati, Krishna Kiran
2015-12-01
Avascular necrosis of hip typically presents in young patients. Core decompression in precollapse stage provides pain relief and preservation of femoral head. The results of core decompression vary considerably despite early diagnosis. The role of MRI in monitoring patients post surgically has not been clearly defined. To study pre and post core decompression MRI changes in avascular necrosis of hip. This is a contiguous observational cohort of 40 hips treated by core decompression for precollapse avascular necrosis of femoral head, who had a baseline MRI performed before surgery. Core decompression of the femoral head was performed within 4 weeks. Follow up radiograph and MRI scans were done at six months. Harris hip score preoperatively, 1 month and 6 months after the surgery was noted. Success in this study was defined as postoperative increase in Harris hip score (HHS) by 20 points and no additional femoral collapse. End point of clinical adverse outcome as defined by fall in Harris hip score was conversion or intention to convert to total hip replacement (THR). MRI parameters in the follow up scan were compared to the preoperative MRI. Effect of core decompression on bone marrow oedema and femoral head collapse was noted. Results were analysed using SPSS software version. Harris hip score improved from 57 to 80 in all patients initially. Six hips had a fall in Harris hip score to mean value of 34.1 during follow up (9 to 12 months) and underwent total hip replacement. MRI predictors of positive outcome are lesions with grade A extent, Grade A & B location. Bone marrow oedema with lesions less than 50% involvement, medial and central location. Careful selection of patients by MR criteria for core decompression provides satisfactory outcome in precollapse stage of avascular necrosis of hip.
Jäger, Marcus; van Wasen, Andrea; Warwas, Sebastian; Landgraeber, Stefan; Haversath, Marcel; Group, VITAS
2014-01-01
Since polyethylene is one of the most frequently used biomaterials as a liner in total hip arthroplasty, strong efforts have been made to improve design and material properties over the last 50 years. Antioxidants seems to be a promising alternative to further increase durability and reduce polyethylene wear in long term. As of yet, only in vitro results are available. While they are promising, there is yet no clinical evidence that the new material shows these advantages in vivo. To answer the question if vitamin-E enhanced ultra-high molecular weight polyethylene (UHMWPE) is able to improve long-term survivorship of cementless total hip arthroplasty we initiated a randomized long-term multicenter trial. Designed as a superiority study, the oxidation index assessed in retrieval analyses of explanted liners was chosen as primary parameter. Radiographic results (wear rate, osteolysis, radiolucency) and functional outcome (Harris Hip Scores, University of California-Los Angeles, Hip Disability and Osteoarthritis Outcome Score, Visual Analogue Scale) will serve as secondary parameters. Patients with the indication for a cementless total hip arthroplasty will be asked to participate in the study and will be randomized to either receive a standard hip replacement with a highly cross-linked UHMWPE-X liner or a highly cross-linked vitamin-E supplemented UHMWPE-XE liner. The follow-up will be 15 years, with evaluation after 5, 10 and 15 years. The controlled randomized study has been designed to determine if Vitamin-E supplemented highly cross-linked polyethylene liners are superior to standard XLPE liners in cementless total hip arthroplasty. While several studies have been started to evaluate the influence of vitamin-E, most of them evaluate wear rates and functional results. The approach used for this multicenter study, to analyze the oxidation status of retrieved implants, should make it possible to directly evaluate the ageing process and development of the implant material itself over a time period of 15 years. PMID:25002933
Single-stage revision for fungal peri-prosthetic joint infection: a single-centre experience.
Klatte, T O; Kendoff, D; Kamath, A F; Jonen, V; Rueger, J M; Frommelt, L; Gebauer, M; Gehrke, T
2014-04-01
Fungal peri-prosthetic infections of the knee and hip are rare but likely to result in devastating complications. In this study we evaluated the results of their management using a single-stage exchange technique. Between 2001 and 2011, 14 patients (ten hips, four knees) were treated for a peri-prosthetic fungal infection. One patient was excluded because revision surgery was not possible owing to a large acetabular defect. One patient developed a further infection two months post-operatively and was excluded from the analysis. Two patients died of unrelated causes. After a mean of seven years (3 to 11) a total of ten patients were available for follow-up. One patient, undergoing revision replacement of the hip, had a post-operative dislocation. Another patient, undergoing revision replacement of the knee, developed a wound infection and required revision 29 months post-operatively following a peri-prosthetic femoral fracture. The mean Harris hip score increased to 74 points (63 to 84; p < 0.02) in those undergoing revision replacement of the hip, and the mean Hospital for Special Surgery knee score increased to 75 points (70 to 80; p < 0.01) in those undergoing revision replacement of the knee. A single-stage revision following fungal peri-prosthetic infection is feasible, with an acceptable rate of a satisfactory outcome.
Memtsoudis, Stavros G; Poeran, Jashvant; Zubizarreta, Nicole; Olson, Ashley; Cozowicz, Crispiana; Mörwald, Eva E; Mariano, Edward R; Mazumdar, Madhu
2018-06-07
Neuraxial anesthesia is increasingly recommended for hip/knee replacements as some studies show improved outcomes on the individual level. With hospital-level studies lacking, we assessed the relationship between hospital-level neuraxial anesthesia utilization and outcomes. National data on 808,237 total knee and 371,607 hip replacements were included (Premier Healthcare 2006 to 2014; 550 hospitals). Multivariable associations were measured between hospital-level neuraxial anesthesia volume (subgrouped into quartiles) and outcomes (respiratory/cardiac complications, blood transfusion/intensive care unit need, opioid utilization, and length/cost of hospitalization). Odds ratios (or percent change) and 95% CI are reported. Volume-outcome relationships were additionally assessed by plotting hospital-level neuraxial anesthesia volume against predicted hospital-specific outcomes; trend tests were applied with trendlines' R statistics reported. Annual hospital-specific neuraxial anesthesia volume varied greatly: interquartile range, 3 to 78 for hips and 6 to 163 for knees. Increasing frequency of neuraxial anesthesia was not associated with reliable improvements in any of the study's clinical outcomes. However, significant reductions of up to -14.1% (95% CI, -20.9% to -6.6%) and -15.6% (95% CI, -22.8% to -7.7%) were seen for hospitalization cost in knee and hip replacements, respectively, both in the third quartile of neuraxial volume. This coincided with significant volume effects for hospitalization cost; test for trend P < 0.001 for both procedures, R 0.13 and 0.41 for hip and knee replacements, respectively. Increased hospital-level use of neuraxial anesthesia is associated with lower hospitalization cost for lower joint replacements. However, additional studies are needed to elucidate all drivers of differences found before considering hospital-level neuraxial anesthesia use as a potential marker of quality.
Cemented total hip replacement cable debris and acetabular construct durability.
Altenburg, Aaron J; Callaghan, John J; Yehyawi, Tameem M; Pedersen, Douglas R; Liu, Steve S; Leinen, Jessica A; Dahl, Kevin A; Goetz, Devon D; Brown, Thomas D; Johnston, Richard C
2009-07-01
Third-body wear can adversely affect the outcome of total hip arthroplasty by causing increased polyethylene wear, osteolysis, and component loosening. We hypothesized that there would be greater generation and migration of metal debris to the bearing surfaces in hips in which cobalt-chromium cables were used to reattach the osteotomized greater trochanter when compared with hips in which stainless steel wires were used. Between June 1981 and December 1983, 196 consecutive total hip arthroplasties were performed with use of an Iowa stem and a titanium-backed cemented acetabular component, with cobalt-chromium cable trochanteric reattachment. After nineteen to twenty years of follow-up, the patients were evaluated with regard to the depth of head penetration into the polyethylene (as a surrogate for wear), osteolysis, loosening, and the need for revision. The results were compared with those for a series of 304 total hip arthroplasties that were performed by the same surgeon from January 1984 to December 1985 with use of the same components and the same surgical technique, but with stainless steel wire trochanteric reattachment. The two groups had a comparable nineteen to twenty-year follow-up. All living patients (fifty-nine hips in the cable group and ninety-two hips in the wire group) had minimum ten-year follow-up radiographs. The polyethylene wear rate was 0.101 mm/yr for the cable group and 0.082 mm/yr for the wire group (p = 0.039). For the living patients, the rate of revision of the acetabular component because of aseptic loosening was 37.3% (twenty-two hips) for the cable group and 20.7% (nineteen hips) for the wire group (p = 0.025). The rate of acetabular osteolysis was 44% (twenty-six hips) for the cable group and 26% (twenty-four hips) for the wire group (p = 0.022). Kaplan-Meier analysis with revision of the acetabular component because of aseptic loosening as the end point demonstrated survival rates of 73.7% +/- 9% and 83% +/- 7% for the cable and wire groups, respectively, at twenty years (p = 0.03). Because cable trochanteric attachment led to significantly greater polyethylene wear, osteolysis, acetabular loosening, and acetabular revision, presumably due to third-body metallic debris generation in this cemented total hip replacement construct, surgeons should be aware of the deleterious effects of third-body debris and avoid the use of potential debris generators in the total hip arthroplasty construct. If cable is used and fretting is recognized, especially with intra-articular migration of metallic material or nonunion of the greater trochanter, consideration should be given to cable removal.
The, Bertram; Hosman, Anton; Kootstra, Johan; Kralj-Iglic, Veronika; Flivik, Gunnar; Verdonschot, Nico; Diercks, Ron
2008-01-01
The main concern in the long run of total hip replacements is aseptic loosening of the prosthesis. Optimization of the biomechanics of the hip joint is necessary for optimization of long-term success. A widely implementable tool to predict biomechanical consequences of preoperatively planned reconstructions still has to be developed. A potentially useful model to this purpose has been developed previously. The aim of this study is to quantify the association between the estimated hip joint contact force by this biomechanical model and RSA-measured wear rates in a clinical setting. Thirty-one patients with a total hip replacement were measured with RSA, the gold standard for clinical wear measurements. The reference examination was done within 1 week of the operation and the follow-up examinations were done at 1, 2 and 5 years. Conventional pelvic X-rays were taken on the same day. The contact stress distribution in the hip joint was determined by the computer program HIPSTRESS. The procedure for the determination of the hip joint contact stress distribution is based on the mathematical model of the resultant hip force in the one-legged stance and the mathematical model of the contact stress distribution. The model for the force requires as input data, several geometrical parameters of the hip and the body weight, while the model for stress requires as input data, the magnitude and direction of the resultant hip force. The stress distribution is presented by the peak stress-the maximal value of stress on the weight-bearing area (p(max)) and also by the peak stress calculated with respect to the body weight (p(max)/W(B)) which gives the effect of hip geometry. Visualization of the relations between predicted values by the model and the wear at different points in the follow-up was done using scatterplots. Correlations were expressed as Pearson r values. The predicted p(max) and wear were clearly correlated in the first year post-operatively (r = 0.58, p = 0.002), while this correlation is weaker after 2 years (r = 0.19, p = 0.337) and 5 years (r = 0.24, p = 0.235). The wear values at 1, 2 and 5 years post-operatively correlate with each other in the way that is expected considering the wear velocity curve of the whole group. The correlation between the predicted p(max) values of two observers who were blinded for each other's results was very good (r = 0.93, p < 0.001). We conclude that the biomechanical model used in this paper provides a scientific foundation for the development of a new way of constructing preoperative biomechanical plans for total hip replacements.
[Gluteal compartment syndrome after total hip replacement. A presentation of two cases].
Villalba, J; Solernou, X
2013-01-01
Many postoperative complications have been described after a total hip arthroplasty, with early and acute, as well as late, complications being reported. Two cases of compartment syndrome of the buttock are described following a hybrid total hip arthroplasty (cemented stem and press-fit and screwed acetabulum) performed on 2 patients of 60 and 68 years old, both diagnosed and treated 24-48 hours after the surgery. Both cases had a primary prosthesis with no previous significant pathological findings. This condition is still rare, and few cases have been described at the medical literature. Copyright © 2012 SECOT. Published by Elsevier Espana. All rights reserved.
Contemporary Strategies for Rapid Recovery Total Hip Arthroplasty.
Stambough, Jeffrey B; Beaulé, Paul E; Nunley, Ryan M; Clohisy, John
2016-01-01
Over the past several years, rapid recovery protocols for total hip arthroplasty have evolved in parallel with advancements in pain management, regional anesthesia, focused rehabilitation, and the patient selection process. As fiscal pressures from payers of health care increase, surgical outcomes and complications are being scrutinized, which evokes a sense of urgency for arthroplasty surgeons as well as hospitals. The implementation of successful accelerated recovery pathways for total hip arthroplasty requires the coordinated efforts of surgeons, practice administrators, anesthesiologists, nurses, physical and occupational therapists, case managers, and postacute care providers. To optimize performance outcomes, it is important for surgeons to select patients who are eligible for rapid recovery. The fundamental tenets of multimodal pain control, regional anesthesia, prudent perioperative blood management, venous thromboembolic prophylaxis, and early ambulation and mobility should be collectively addressed for all patients who undergo primary total hip replacement.
Quality Indicators for Quality of Care During Hospitalization for Vulnerable Elder Persons
2004-08-01
hip fracture as well as all abdominal, pelvic or lower extremity surgeries above the shin, except laparoscopic surgeries, and patients with prior...24 63. Williams MA, Campbell EB, Raynor WJ, Mlynarczyk SM, Ward SE. Reducing acute confusional states in elderly patients with hip fractures ...studies of patients receiving total hip replacements) but inferior to the acceptable regimens above. Pulmonary embolism, the sequelae of deep vein
Gofton, Wade; Fitch, David A
2016-03-01
The purpose of this study was to compare the in-hospital costs associated with the tissue-sparing supercapsular percutaneously-assisted total hip (SuperPath) and traditional Lateral surgical techniques for total hip replacement (THR). Between April 2013 and January 2014, in-hospital costs were reviewed for all THRs performed using the SuperPath technique by a single surgeon and all THRs performed using the Lateral technique by another surgeon at the same institution. Overall, costs were 28.4% higher in the Lateral group. This was largely attributable to increased costs associated with transfusion (+92.5%), patient rooms (+60.4%), patient food (+62.8%), narcotics (+42.5%), physical therapy (+52.5%), occupational therapy (+88.6%), and social work (+92.9%). The only costs noticeably increased for SuperPath were for imaging (+105.9%), and this was because the SuperPath surgeon performed intraoperative radiographs on all patients while the Lateral surgeon did not. The use of the SuperPath technique resulted in in-hospital cost reductions of over 28%, suggesting that this tissue-sparing surgical technique can be cost-effective primarily by facilitating early mobilisation and patient discharge even during a surgeon's initial experience with the approach.
Senay, Andréa; Trottier, Milanne; Delisle, Josée; Banica, Andreea; Benoit, Benoit; Laflamme, G Yves; Malo, Michel; Nguyen, Hai; Ranger, Pierre; Fernandes, Julio C
2018-01-01
Low-molecular-weight heparin (LMWH) is a recommended anticoagulant for thromboprophylaxis after major orthopedic surgery. Dabigatran etexilate is an oral anticoagulant recognized as noninferior to LMWH. We aimed to assess the incidence of symptomatic venous thromboembolic events (VTEs) after discharge in patients who underwent joint replacement, using a hospital registry. Patients who underwent total knee and hip arthroplasty between September 2011 and March 2015 were selected. Subcutaneous enoxaparin (30 mg twice daily) was given during hospitalization. At discharge, patients received either enoxaparin 30 mg twice daily/40 mg once daily or dabigatran 220 mg/150 mg once daily. Patients were seen or called at 2, 6, and 12 weeks after surgery. Outcomes were the number of VTEs, including deep venous thrombosis, pulmonary embolism, and the number of major/minor bleeding events after discharge. After discharge, 1468 patients were prescribed enoxaparin and 904 dabigatran (1396 total knee arthroplasty and 976 total hip arthroplasty patients). Mean age was 66±10 years, and 60% were female. The cumulative incidence of VTEs during the 12-week follow-up was 0.7%. One patient sustained a VTE during the switch window. Seven patients sustained a pulmonary embolism (0.3%). There was no statistical difference between the total knee arthroplasty and total hip arthroplasty groups. The incidence of major and minor bleeding events during follow-up was 0.3% and 30.3%, respectively. These events had a higher incidence in the dabigatran group compared to the enoxaparin group after discharge ( p <0.05), but not between knee and hip replacement groups for major bleeding events. A pharmaceutical prophylaxis protocol using LMWH and dabigatran during the post-discharge period resulted in low incidences of VTE and equivalence between treatments. However, the increased number of major and minor bleeding events in patients taking dabigatran is of concern regarding the safety and needs to be evaluated using analyses adjusted for risk factors.
Migration characteristics and early clinical results of the NANOS® short-stem hip arthroplasty.
Kaipel, Martin; Grabowiecki, Phillip; Sinz, Katrina; Farr, Sebastian; Sinz, Günter
2015-05-01
Femoral short stems promise essential advantages in total hip arthroplasty. Up to now, only short- and midterm clinical studies exist. Data on early stem migration that could predict later aseptic loosening at an early stage are rare. The purpose of this study was to assess migration patterns and clinical outcome 2 years after hip replacement by a metaphyseal anchored cementless short stem. Migration data and clinical results were prospectively assessed in 49 patients. Clinical outcome was measured using the Harris Hip Score (HHS). Migration analyses were performed using the computer-assisted Einzel-Bild-Roentgen-Analyse (EBRA) system. At 2 years after surgery, none of the implants needed revision, and HHS increased from 47.9 up to 98.1. Of 49 patients, 5 (10%) showed increased vertical stem migration (1.5 mm/2a) that might predict late aseptic loosening. Of 49 stems, 44 (90%) showed stable migration patterns indicating a beneficial long-term outcome. Results of this study confirm the excellent clinical data of previous works. Migration patterns strongly suggest that short-stem arthroplasty is not only an innovative but also a reliable strategy in total hip replacement.
Celiac disease is not increased in women with hip fractures and low vitamin D levels.
Leboff, M S; Cobb, H; Gao, L Y; Hawkes, W; Yu-Yahiro, J; Kolatkar, N S; Magaziner, J
2013-01-01
Celiac disease is associated with decreased bone density; however, the risk of fractures in celiac disease patients is unclear. We compared the prevalence of celiac disease between a group of women with hip fractures and a group of women undergoing elective joint replacement surgery and the association between celiac disease and vitamin D levels. Two hundred eight community dwelling and postmenopausal women were recruited from Boston, MA (n=81) and Baltimore, MD (n=127). We measured tissue transglutaminase IgA by ELISA to diagnose celiac disease and 25-hydroxyvitamin D (25(OH)D) levels by radioimmunoassay in both women with hip fractures (n=157) and a control group (n=51) of total hip replacement subjects from Boston. Subjects were excluded if they took any medications or had medical conditions that might affect bone. Median serum 25(OH)D levels were significantly lower (p< 0.0001) in the hip fracture cohorts compared to the elective joint replacement cohort (14.1 ng/ml vs. 21.3 ng/ml, respectively). There were no differences in the percentage of subjects with a positive tissue transglutaminase in the women with hip fractures versus the control group (1.91% vs. 1.96%, respectively). Vitamin D levels are markedly reduced in women with hip fractures, however hip fracture patients did not show a higher percentage of positive tissue transglutaminase levels compared with controls. These data suggest that routine testing for celiac disease among hip fracture patients may not be necessary in the absence of clinical signs and symptoms, although data from larger studies among hip fracture subjects are needed.
Telemedicine support shortens length of stay after fast-track hip replacement.
Vesterby, Martin Svoldgaard; Pedersen, Preben Ulrich; Laursen, Malene; Mikkelsen, Søren; Larsen, Jens; Søballe, Kjeld; Jørgensen, Lene Bastrup
2017-02-01
Background and purpose - Telemedicine could allow patients to be discharged more quickly after surgery and contribute to improve fast-track procedures without compromising quality, patient safety, functionality, anxiety, or other patient-perceived parameters. We investigated whether using telemedicine support (TMS) would permit hospital discharge after 1 day without loss of self-assessed quality of life, loss of functionality, increased anxiety, increased rates of re-admission, or increased rates of complications after hip replacement. Patients and methods - We performed a randomized controlled trial involving 72 Danish patients in 1 region who were referred for elective fast-track total hip replacement between August 2009 and March 2011 (654 were screened for eligibility). Half of the patients received a telemedicine solution connected to their TV. The patients were followed until 1 year after surgery. Results - Length of stay was reduced from 2.1 days (95% CI: 2.0-2.3) to 1.1 day (CI: 0.9-1.4; p < 0.001) with the TMS intervention. Health-related quality of life increased in both groups, but there were no statistically significant differences between groups. There were also no statistically significant differences between groups regarding timed up-and-go test and Oxford hip score at 3-month follow-up. At 12-month follow-up, the rates of complications and re-admissions were similar between the groups, but the number of postoperative hospital contacts was lower in the TMS group. Interpretation - Length of postoperative stay was shortened in patients with the TMS solution, without compromising patient-perceived or clinical parameters in patients undergoing elective fast-track surgery. These results indicate that telemedicine can be of value in fast-track treatment of patients undergoing total hip replacement.
Mu, Dong-Liang; Zhang, Da-Zhi; Wang, Dong-Xin; Wang, Geng; Li, Chun-Jing; Meng, Zhao-Ting; Li, Ya-Wei; Liu, Chao; Li, Xue-Ying
2017-06-01
Severe pain and high-dose opioids are both associated with increased risk of postoperative delirium. The authors investigated whether parecoxib-supplemented IV morphine analgesia could decrease the incidence of delirium in elderly patients after total hip or knee replacement surgery. In a randomized, double-blind, 2-center trial, patients of 60 years or older who underwent elective total hip or knee replacement surgery were assigned in a 1:1 ratio to receive either parecoxib (40 mg at the end of surgery and then every 12 hours for 3 days) or placebo (normal saline). All patients received combined spinal-epidural anesthesia during surgery and IV morphine for postoperative analgesia. The primary outcome was the incidence of delirium within 5 days after surgery. Between January 2011 and May 2013, 620 patients were enrolled and were included in the intention-to-treat and safety analyses. The incidence of delirium was significantly reduced from 11.0% (34/310) with placebo to 6.2% (19/310) with parecoxib (relative risk 0.56, 95% confidence interval 0.33-0.96, P = .031). The severity of pain and the cumulative consumptions of morphine at 24, 48, and 72 hours after surgery were significantly lower with parecoxib than with placebo (all P < .001), although the differences were small. There was no difference in the incidence of postoperative complications between the 2 groups (12.3% [38/310] with placebo versus 11.6% [36/310] with parecoxib; P = .80). For low-risk elderly patients undergoing elective total hip or knee replacement surgery, multidose parecoxib supplemented to IV morphine decreased the incidence of postoperative delirium without increasing adverse events.
Dissociation of modular total hip arthroplasty at the neck-stem interface without dislocation.
Kouzelis, A; Georgiou, C S; Megas, P
2012-12-01
Modular femoral and acetabular components are now widely used, but only a few complications related to the modularity itself have been reported. We describe a case of dissociation of the modular total hip arthroplasty (THA) at the femoral neck-stem interface during walking. The possible causes of this dissociation are discussed. Successful treatment was provided with surgical revision and replacement of the modular neck components. Surgeons who use modular components in hip arthroplasties should be aware of possible early complications in which the modularity of the prostheses is the major factor of failure.
Ke, Xijian; Li, Ji; Liu, Yong; Wu, Xi; Mei, Wei
2017-06-26
Anesthesia management for patients with severe ankylosing spondylitis scheduled for total hip arthroplasty is challenging due to a potential difficult airway and difficult neuraxial block. We report 4 cases with ankylosing spondylitis successfully managed with a combination of lumbar plexus, sacral plexus and T12 paravertebral block. Four patients were scheduled for total hip arthroplasty. All of them were diagnosed as severe ankylosing spondylitis with rigidity and immobilization of cervical and lumbar spine and hip joints. A combination of T12 paravertebral block, lumbar plexus and sacral plexus block was successfully used for the surgery without any additional intravenous anesthetic or local anesthetics infiltration to the incision, and none of the patients complained of discomfort during the operations. The combination of T12 paravertebral block, lumbar plexus and sacral plexus block, which may block all nerves innervating the articular capsule, surrounding muscles and the skin involved in total hip arthroplasty, might be a promising alternative for total hip arthroplasty in ankylosing spondylitis.
Mustafa, Z; Chapman, K; Irven, C; Carr, A J; Clipsham, K; Chitnavis, J; Sinsheimer, J S; Bloomfield, V A; McCartney, M; Cox, O; Sykes, B; Loughlin, J
2000-03-01
To examine 11 candidate genes as susceptibility loci for osteoarthritis (OA). A total of 481 families have been ascertained in which at least two siblings have had joint replacement surgery of the hip, or knee, or hip and knee for idiopathic OA. Each candidate gene was targeted using one or more intragenic or closely linked microsatellite marker. The linkage data were analysed unstratified and following stratification by sex and by joint replaced (hip or knee). The analyses revealed suggestive linkage of the type IX collagen gene COL9A1 (6q12-q13) to a subset of 132 families that contained affected females who were concordant for hip OA (female-hip) with a P-value of 0.00053 and logarithm of the odds (LOD) score of 2.33 [corrected P-value of 0. 0016, corrected LOD score of 1.85]. COL9A1 may therefore be a susceptibility locus for female hip OA. In addition, there was weak evidence of linkage to HLA/COL11A2 (6p21.3) in female hip OA with a corrected P-value of 0.016.
Jin, Z M; Dowson, D; Fisher, J
1997-01-01
Lubrication mechanisms and contact mechanics have been analysed for total hip joint replacements made from hard bearing surfaces such as metal-on-metal and ceramic-on-ceramic. A similar analysis for ultra-high molecular weight polyethylene (UHMWPE) against a hard bearing surface has also been carried out and used as a reference. The most important factor influencing the predicted lubrication film thickness has been found to be the radial clearance between the ball and the socket. Full fluid film lubrication may be achieved in these hard/hard bearings provided that the surface finish of the bearing surface and the radial clearance are chosen correctly and maintained. Furthermore, there is a close relation between the predicted contact half width and the predicted lubrication film thickness. Therefore, it is important to analyse the contact mechanics in artificial hip joint replacements. Practical considerations of manufacturing these bearing surfaces have also been discussed.
Health service costs in Europe: cost and reimbursement of primary hip replacement in nine countries.
Stargardt, Tom
2008-01-01
This paper assesses variations in the cost of primary hip replacement between and within nine member states of the European Union (EU). It also compares the cost of service with public-payer reimbursements. To do so, data on cost and reimbursement were surveyed at the micro-level in 42 hospitals in Denmark, England, France, Germany, Hungary, Italy, The Netherlands, Poland, and Spain. The total cost of treatment ranged from 1290 euros (Hungary) to 8739 euros (The Netherlands), with a mean cost of 5043 euros (STD +/- 2071 euros). The main cost drivers were found to be implants (34% of total cost on average) and ward costs (20.9% of total cost on average). A one-way random effects analysis of variance model indicated that 74.0% of variation was between and only 26% of variation was within countries. In a two-level random-intercept regression model, purchasing-power parities explained 79.4% of the explainable between-country variation, while the percentage of uncemented implants used and the number of beds explained 12.1 and 1.6% of explainable within-country variation, respectively. The large differences in cost and reimbursement between Poland, Hungary, and the other EU member states shows that primary total hip replacement is a highly relevant case for cross-border care. Copyright 2008 John Wiley & Sons, Ltd.
[Unusual infection complication of total hip arthroplasty].
Jány, R; Vojtassák, J; Lisý, M; Almási, J
2005-01-01
Authors present the case history of a 66-year old patient after repeated reimplantations of the THA with a deep infect caused by a rare aetiological agent (Serratia marcescens) associated with a pyogenic sinus. They describe the disease history, therapeutic procedure, complications associated with the surgery as well as postoperative course after the reimplantation of a customized total hip replacement. In the conclusion they state that in case of an infected total hip arthroplasty the treatment is focused on the salvage of the infection process and preservation of the function of the affected limb. Of essential importance is surgical revision with a radical removal of necrotic tissues and hardware in combination with an intensive parenteral antibiotic administration.
Chitnavis, J; Sinsheimer, J S; Suchard, M A; Clipsham, K; Carr, A J
2000-06-01
To determine and compare the aetiological background, clinical patterns and radiological features of idiopathic osteoarthritis (OA) of the hip and the knee warranting arthroplasty. A total of 402 Caucasians consecutively undergoing total hip replacement (THR) or total knee replacement (TKR) for idiopathic OA at a major centre was surveyed. Previous joint injury was more common in the TKR group (P < 0.0001). However, both groups manifested a mixed occupational background, body mass indices similar to the general population and a predominance of females (F:M = 1.3-1.4:1). The TKR group had a significantly younger age of symptom onset (56 yr) than the THR group (61 yr) but both groups had a tendency to bilateral arthroplasty (33%), nodal involvement (54-59%), a significant excess of right-sided replacements (1.8:1, THR; 2.2:1, TKR) and similar levels of pre-operative pain and disability. Up to 40% of hips manifested acetabular dysplasia and 10% possible previous slipped upper femoral epiphyses. Eighty-five per cent with end-stage coxarthrosis or gonarthrosis had an identical pattern of radiographic disease contralaterally. Our data suggest the importance of a constitutional tendency to idiopathic, end-stage OA, a disorder traditionally associated with environmental factors leading to 'wear and tear'.
Landgraeber, Stefan; Quitmann, Henning; Güth, Sebastian; Haversath, Marcel; Kowalczyk, Wojciech; Kecskeméthy, Andrés; Heep, Hansjörg; Jäger, Marcus
2013-01-01
There is still controversy as to whether minimally invasive total hip arthroplasty enhances the postoperative outcome. The aim of this study was to compare the outcome of patients who underwent total hip replacement through an anterolateral minimally invasive (MIS) or a conventional lateral approach (CON). We performed a randomized, prospective study of 75 patients with primary hip arthritis, who underwent hip replacement through the MIS (n=36) or CON (n=39) approach. The Western Ontario and McMaster Universities Osteoarthritis Index and Harris Hip score (HHS) were evaluated at frequent intervals during the early postoperative follow-up period and then after 3.5 years. Pain sensations were recorded. Serological and radiological analyses were performed. In the MIS group the patients had smaller skin incisions and there was a significantly lower rate of patients with a positive Trendelenburg sign after six weeks postoperatively. After six weeks the HHS was 6.85 points higher in the MIS group (P=0.045). But calculating the mean difference between the baseline and the six weeks HHS we evaluated no significant differences. Blood loss was greater and the duration of surgery was longer in the MIS group. The other parameters, especially after the twelfth week, did not differ significantly. Radiographs showed the inclination of the acetabular component to be significantly higher in the MIS group, but on average it was within the same permitted tolerance range as in the CON group. Both approaches are adequate for hip replacement. Given the data, there appears to be no significant long term advantage to the MIS approach, as described in this study. PMID:24191179
Cemented Total Hip Replacement Cable Debris and Acetabular Construct Durability
Altenburg, Aaron J.; Callaghan, John J.; Yehyawi, Tameem M.; Pedersen, Douglas R.; Liu, Steve S.; Leinen, Jessica A.; Dahl, Kevin A.; Goetz, Devon D.; Brown, Thomas D.; Johnston, Richard C.
2009-01-01
Background: Third-body wear can adversely affect the outcome of total hip arthroplasty by causing increased polyethylene wear, osteolysis, and component loosening. We hypothesized that there would be greater generation and migration of metal debris to the bearing surfaces in hips in which cobalt-chromium cables were used to reattach the osteotomized greater trochanter when compared with hips in which stainless steel wires were used. Methods: Between June 1981 and December 1983, 196 consecutive total hip arthroplasties were performed with use of an Iowa stem and a titanium-backed cemented acetabular component, with cobalt-chromium cable trochanteric reattachment. After nineteen to twenty years of follow-up, the patients were evaluated with regard to the depth of head penetration into the polyethylene (as a surrogate for wear), osteolysis, loosening, and the need for revision. The results were compared with those for a series of 304 total hip arthroplasties that were performed by the same surgeon from January 1984 to December 1985 with use of the same components and the same surgical technique, but with stainless steel wire trochanteric reattachment. The two groups had a comparable nineteen to twenty-year follow-up. All living patients (fifty-nine hips in the cable group and ninety-two hips in the wire group) had minimum ten-year follow-up radiographs. Results: The polyethylene wear rate was 0.101 mm/yr for the cable group and 0.082 mm/yr for the wire group (p = 0.039). For the living patients, the rate of revision of the acetabular component because of aseptic loosening was 37.3% (twenty-two hips) for the cable group and 20.7% (nineteen hips) for the wire group (p = 0.025). The rate of acetabular osteolysis was 44% (twenty-six hips) for the cable group and 26% (twenty-four hips) for the wire group (p = 0.022). Kaplan-Meier analysis with revision of the acetabular component because of aseptic loosening as the end point demonstrated survival rates of 73.7% ± 9% and 83% ± 7% for the cable and wire groups, respectively, at twenty years (p = 0.03). Conclusions: Because cable trochanteric attachment led to significantly greater polyethylene wear, osteolysis, acetabular loosening, and acetabular revision, presumably due to third-body metallic debris generation in this cemented total hip replacement construct, surgeons should be aware of the deleterious effects of third-body debris and avoid the use of potential debris generators in the total hip arthroplasty construct. If cable is used and fretting is recognized, especially with intra-articular migration of metallic material or nonunion of the greater trochanter, consideration should be given to cable removal. Level of Evidence: Therapeutic Level III. See Instructions to Authors for a complete description of levels of evidence. PMID:19571089
MRI Evaluation of Post Core Decompression Changes in Avascular Necrosis of Hip
Marupaka, Sravan Kumar; Alluri, Swathi; MD, Naseeruddin; Irfan, Kazi Amir; Jampala, Venkateshwarlu; Apsingi, Sunil; Eachempati, Krishna Kiran
2015-01-01
Introduction Avascular necrosis of hip typically presents in young patients. Core decompression in precollapse stage provides pain relief and preservation of femoral head. The results of core decompression vary considerably despite early diagnosis. The role of MRI in monitoring patients post surgically has not been clearly defined. Aim To study pre and post core decompression MRI changes in avascular necrosis of hip. Materials and Methods This is a contiguous observational cohort of 40 hips treated by core decompression for precollapse avascular necrosis of femoral head, who had a baseline MRI performed before surgery. Core decompression of the femoral head was performed within 4 weeks. Follow up radiograph and MRI scans were done at six months. Harris hip score preoperatively, 1 month and 6 months after the surgery was noted. Success in this study was defined as postoperative increase in Harris hip score (HHS) by 20 points and no additional femoral collapse. End point of clinical adverse outcome as defined by fall in Harris hip score was conversion or intention to convert to total hip replacement (THR). MRI parameters in the follow up scan were compared to the preoperative MRI. Effect of core decompression on bone marrow oedema and femoral head collapse was noted. Results were analysed using SPSS software version. Results Harris hip score improved from 57 to 80 in all patients initially. Six hips had a fall in Harris hip score to mean value of 34.1 during follow up (9 to 12 months) and underwent total hip replacement. MRI predictors of positive outcome are lesions with grade A extent, Grade A & B location. Bone marrow oedema with lesions less than 50% involvement, medial and central location. Conclusion Careful selection of patients by MR criteria for core decompression provides satisfactory outcome in precollapse stage of avascular necrosis of hip. PMID:26816966
Splash in elective primary knee and hip replacement: are we adequately protected?
Singh, V K; Kalairajah, Y
2009-08-01
An intra-operative splash is a common occurrence in elective knee and hip replacement surgery and can potentially transmit bloodborne diseases, with devastating consequences. This study aimed to quantify the risk of a splash and to assess its correlation with body mass index, duration of surgery and the volume of lavage fluid used. Between December 2007 and April 2008, 62 consecutive patients (38 women, 24 men) undergoing an elective total knee or total hip replacement (TKR, THR) were recruited into the study (32 TKRs and 30 THRs) after appropriate consent. A splash occurred in all 62 cases. A THR had a slightly higher risk of a splash than a TKR, but this was not statistically significant (p = 0.27). The correlation between body mass index, duration of surgery and the amount of pulse lavage used with a splash was r = 0.013, (non-significant), r = 0.52, (significant) and r = 0.92 (highly significant), respectively. A high number of splashes are generated during a TKR and a THR. The simple visor mask fails to protect the surgeon, the assistant or the patient from the risk of a splash and reverse splash, respectively.
The effects of the empowerment education program in older adults with total hip replacement surgery.
Huang, Tzu-Ting; Sung, Chia-Chun; Wang, Woan-Shyuan; Wang, Bi-Hwa
2017-08-01
To measure the effectiveness of an education empowerment program on primary (self-efficacy and self-care competence) and secondary outcomes (Activities of Daily Life, mobility, depressive mood and quality of life) for older adults with total hip replacement surgery. Degenerative arthritis is a common and serious chronic illness that impacts the quality of life of older adults. As joints continue to degenerate and the hip damaged by arthritis, activities of daily life will be difficult to perform due to severe hip pain and joint stiffness. Therefore, hip replacement surgery should be considered and effective nursing care should be provided to improve the recovery of older adults. A prospective randomized control trial. A trial was conducted from September 2013 - May 2014 in two hospitals in northern Taiwan. 108 participants were random assigned to either the education empowerment group or in the comparison group. The researchers collected baseline data at admission and outcomes on the day of discharge, one month after and three months after the discharge. After the interventions, the education empowerment group participants demonstrated significantly higher self-care competence and self-efficacy and lower depressive inclinations compared with those in the comparison group. Participants in both groups significantly improved on activities of daily life, mobility and quality of life over the course of the interventions. This education empowerment intervention was very effective in enhancing participants' outcomes. Moreover, involving both older adults and their caregivers for the participation this program is recommended for a greater impact. © 2017 John Wiley & Sons Ltd.
Computer Assisted Surgery and Current Trends in Orthopaedics Research and Total Joint Replacements
NASA Astrophysics Data System (ADS)
Amirouche, Farid
2008-06-01
Musculoskeletal research has brought about revolutionary changes in our ability to perform high precision surgery in joint replacement procedures. Recent advances in computer assisted surgery as well better materials have lead to reduced wear and greatly enhanced the quality of life of patients. The new surgical techniques to reduce the size of the incision and damage to underlying structures have been the primary advance toward this goal. These new techniques are known as MIS or Minimally Invasive Surgery. Total hip and knee Arthoplasties are at all time high reaching 1.2 million surgeries per year in the USA. Primary joint failures are usually due to osteoarthristis, rheumatoid arthritis, osteocronis and other inflammatory arthritis conditions. The methods for THR and TKA are critical to initial stability and longevity of the prostheses. This research aims at understanding the fundamental mechanics of the joint Arthoplasty and providing an insight into current challenges in patient specific fitting, fixing, and stability. Both experimental and analytical work will be presented. We will examine Cementless total hip arthroplasty success in the last 10 years and how computer assisted navigation is playing in the follow up studies. Cementless total hip arthroplasty attains permanent fixation by the ingrowth of bone into a porous coated surface. Loosening of an ingrown total hip arthroplasty occurs as a result of osteolysis of the periprosthetic bone and degradation of the bone prosthetic interface. The osteolytic process occurs as a result of polyethylene wear particles produced by the metal polyethylene articulation of the prosthesis. The total hip arthroplasty is a congruent joint and the submicron wear particles produced are phagocytized by macrophages initiating an inflammatory cascade. This cascade produces cytokines ultimately implicated in osteolysis. Resulting bone loss both on the acetabular and femoral sides eventually leads to component instability. As patients are living longer and total hip arthroplasty is performed in younger patients the risks of osteolysis associated with cumulative wear is increased. Computer-assisted surgery is based on sensing feedback; vision and imaging that help surgeons align the patient's joints during total knee or hip replacement with a degree of accuracy not possible with the naked eye. For the first time, the computer feedback is essential for ligament balancing and longevity of the implants. The computers navigation systems also help surgeons to use smaller incisions instead of the traditional larger openings. Small-incision surgery offers the potential for faster recovery, less bleeding and less pain for patients. The development of SESCAN imaging technique to create a patient based model of a 3D joint will be presented to show the effective solution of complex geometry of joints.
... Download Download EPUB Download PDF What is it? Points To Remember About Hip Replacement Surgery Hip replacement ... This leaves your hands and arms free for balance or to use crutches. Use a long-handled " ...
Getting your home ready - knee or hip surgery
... Philadelphia, PA: Elsevier; 2017:chap 55. Read More ACL reconstruction Hip fracture surgery Hip joint replacement Knee ... Knee joint replacement Knee microfracture surgery Patient Instructions ACL reconstruction - discharge Hip fracture - discharge Hip or knee ...
Wittbrodt, Eric T; Gan, Tong J; Datto, Catherine; McLeskey, Charles; Sinha, Meenal
2018-01-01
Constipation is a well-known complication of surgery that can be exacerbated by opioid analgesics. This study evaluated resource utilization and costs associated with opioid-induced constipation (OIC). This retrospective, observational, and propensity-matched cohort study utilized the Premier Healthcare Database. The study included adults ≥18 years of age undergoing total hip or total knee replacement as inpatients who received an opioid analgesic and were discharged between January 1, 2012, and June 30, 2015. Diagnosis codes identified patients with OIC who were then matched 1:1 to patients without OIC. Generalized linear and logistic regression models were used to compare inpatient resource utilization, total hospital costs, inpatient mortality, and 30-day all-cause readmissions and emergency department visits. Of 788,448 eligible patients, 40,891 (5.2%) had OIC. Covariates were well balanced between matched patients with and without OIC (n=40,890 each). In adjusted analyses, patients with OIC had longer hospital lengths of stay (3.6 versus 3.3 days; p <0.001), higher total hospital costs (US$17,479 versus US$16,265; p <0.001), greater risk of intensive care unit admission (odds ratio [OR]=1.12, 95% CI: 1.01-1.24), and increased likelihood of 30-day hospital read-missions (OR=1.16, 95% CI: 1.11-1.22) and emergency department visits (OR=1.38, 95% CI: 1.07-1.79) than patients without OIC. No statistically significant difference was found with inpatient mortality (OR=0.89, 95% CI: 0.59-1.35). OIC was associated with greater resource utilization and hospital costs for patients undergoing primarily elective total hip or total knee replacement surgery. These results support OIC screening and management strategies as part of perioperative care management.
[Modern tribology in total hip arthroplasty: pros and cons].
Gómez-García, F
2014-01-01
The wear products and adverse reactions that occur on bearing surfaces represent one of the greatest challenges in prosthetic replacements, as the latter experience increasing demands due to the large number of young and older adult patients that have a long life expectancy and remarkable activity. The purpose of this review is to analyze the pros and cons of the new advances in the bearing components of the articular surfaces of current total hip arthroplasties. We also discuss the strategies used historically, their problems, results and the surgeon's role in prescribing the tribologic couple that best fits each patient's needs. We conclude with practical recommendations for the prescription and management of the latest articular couples for total hip arthroplasty.
Revision Rates after Primary Hip and Knee Replacement in England between 2003 and 2006
Sibanda, Nokuthaba; Copley, Lynn P; Lewsey, Jim D; Borroff, Mick; Gregg, Paul; MacGregor, Alex J; Pickford, Martin; Porter, Martyn; Tucker, Keith; van der Meulen, Jan H
2008-01-01
Background Hip and knee replacement are some of the most frequently performed surgical procedures in the world. Resurfacing of the hip and unicondylar knee replacement are increasingly being used. There is relatively little evidence on their performance. To study performance of joint replacement in England, we investigated revision rates in the first 3 y after hip or knee replacement according to prosthesis type. Methods and Findings We linked records of the National Joint Registry for England and Wales and the Hospital Episode Statistics for patients with a primary hip or knee replacement in the National Health Service in England between April 2003 and September 2006. Hospital Episode Statistics records of succeeding admissions were used to identify revisions for any reason. 76,576 patients with a primary hip replacement and 80,697 with a primary knee replacement were included (51% of all primary hip and knee replacements done in the English National Health Service). In hip patients, 3-y revision rates were 0.9% (95% confidence interval [CI] 0.8%–1.1%) with cemented, 2.0% (1.7%–2.3%) with cementless, 1.5% (1.1%–2.0% CI) with “hybrid” prostheses, and 2.6% (2.1%–3.1%) with hip resurfacing (p < 0.0001). Revision rates after hip resurfacing were increased especially in women. In knee patients, 3-y revision rates were 1.4% (1.2%–1.5% CI) with cemented, 1.5% (1.1%–2.1% CI) with cementless, and 2.8% (1.8%–4.5% CI) with unicondylar prostheses (p < 0.0001). Revision rates after knee replacement strongly decreased with age. Interpretation Overall, about one in 75 patients needed a revision of their prosthesis within 3 y. On the basis of our data, consideration should be given to using hip resurfacing only in male patients and unicondylar knee replacement only in elderly patients. PMID:18767900
Fabrication and wear test of a continuous fiber/particulate composite total surface hip replacement
NASA Technical Reports Server (NTRS)
Roberts, J. C.; Ling, F. F.; Jones, W. R., Jr.
1981-01-01
Continuous fiber woven E-glass composite femoral shells having the ame elastic properties as bone were fabricated. The shells were then encrusted with filled epoxy wear resistant coatings and run dry against ultrahigh molecular weight polyethylene acetabular cups in 42,000 and 250,000 cycle were tests on a total hip simulator. The tribological characteristics of these shells atriculating with the acetabular cups are comparable to a vitallium bal articulating with an ultrahigh molecular weight polyethylene cup.
Bouchet, R; Mercier, N; Saragaglia, D
2011-02-01
Dislocation is a frequent complication of total hip arthroplasties (THA) especially in older patients, especially when using a posterior approach. In these cases, dual mobility (DM) cups developed by Gilles Bousquet in 1975 can be indicated to reduce this complication risk. Dual mobility cups reduce the rate of dislocation in primary total hip arthroplasty using posterior approach in a single-surgeon series. Test this hypothesis in a controlled study to compare the rate of dislocation in primary total hip arthroplasties done in patients over 50 years old either with a dual mobility cup or a conventional metal-on-polyethylene 28-mm diameter head. Two consecutive series of primary total hip replacements were performed by a single surgeon using a posterolateral approach. The piriformis tendon was left intact. The DM series included 105 patients who underwent arthroplasty between January 2005 and June 2007 with a dual mobility cup (60 women and 45 men, mean age 76.6±5.65 years old [53-93]). The control series (S series) included 108 patients who underwent arthroplasty (56 women and 52 men, mean age 74.2±5.9 years old [53-87]) with a conventional 28-mm polyethylene cup between January 2003 and June 2005. All hip replacements included a 28-mm metal-polyethylene cup and a 12-14-mm Morse taper. Both groups were comparable for gender, diagnosis, body mass index, type of anesthesia and ASA score distribution. All patients included in this series had a minimum follow-up of 1 year. There were no dislocations in the DM series and five early dislocations (before the third month) in the S series for a rate of 4.63%. Although the rate of dislocation was higher in the S series (4.63% vs 0%), the difference was barely significant (P=0.0597). This study comparing the incidence of dislocations after THA with conventional or dual mobility cups, shows that even using a posterior approach and in older patients, dual mobility cups increase stability with no postoperative dislocations. Although results are barely significant, a larger series should confirm the benefit of this implant. In this series, morbidity was not increased with dual mobility cups. Level III: retrospective case-control study. Copyright © 2010 Elsevier Masson SAS. All rights reserved.
Yang, Li-qing; Li, Xi; Fu, Qin; Wang, Cheng
2013-07-01
To retrospectively study early therapeutic effects of the ceramics to ceramics prosthesis design in treating hip disease. From October 2007 to September 2010, 42 patients (44 hips) with hip disease underwent replacement of total hip. Hip prosthesis designs included the Pinnacle ceramics to ceramics and the Duraloc metal to polyethylene,produced by DePuy Company, all were non-bone cement type of artificial hip joint. Twenty patients (22 hips) were performed with ceramics to ceramics total hip prosthesis (CoC group, there were 12 males and 8 females, aged from 21 to 49 years) and 22 patients (22 hips) were performed with metal to polyethylene total hip prosthesis (MoP group, there were 13 males and 9 females, aged from 42 to 55 years). All the surgical approachs were posterolateral, and the routine anticoagulation and the corresponding functional exercise were performed after operation. The follow-up time was 6 months at least including clinical and radiographic observation. Measured the motion of joint and evaluated the function of hip joint according to Harris classification. All clinical effects were satisfactory and no dislocation ,loosening,infection, deep venous thrombosis and other complications occurred. There was no statistical significance in Harris scoring and the motion of joint between two groups before and after operation (P>0.05). The clinical effect of ceramics to ceramics prosthesis design in improving clinical symptoms and the motion of joint is coordinate with metal to polyethylene total hip prosthesis, however, its advantages and long-term efficacy need further observing. The ceramics to ceramics prosthesis design may be a good choice for the young patients with hip disease because of its good wear resistance.
Burgess, Louise C; Phillips, Stuart M; Wainwright, Thomas W
2018-06-25
Nutritional supplements can influence outcomes for individuals undergoing major surgery, particularly in older persons whose functional reserve is limited. Accelerating recovery from total hip replacement (THR) and total knee replacement (TKR) may offer significant benefits. Therefore, we explored the role of nutritional supplements in improving recovery following THR and TKR. A systematic review was conducted to source randomized clinical trials that tested nutritional supplements in cohorts of THR or TKR patients. Our search yielded nine relevant trials. Intake of a carbohydrate-containing fluid is reported to improve insulin-like growth factor levels, reduce hunger, nausea, and length of stay, and attenuate the decrease in whole-body insulin sensitivity and endogenous glucose release. Amino acid supplementation is reported to reduce muscle atrophy and accelerate return of functional mobility. One paper reported a suppressive effect of beta-hydroxy beta-methylbutyrate, L-arginine, and L-glutamine supplementation on muscle strength loss following TKR. There is limited evidence for nutritional supplementation in THR and TKR pathways; however, the low risk profile and potential benefits to adjunctive treatment methods, such as exercise programs, suggest nutritional supplements may have a role. Optimizing nutritional status pre-operatively may help manage the surgical stress response, with a particular benefit for undernourished, frail, or elderly individuals.
[Efficacy of health education on patients with hip replacement based on the Internet].
Zhou, Yang; Yang, Tubao; Li, Yinglan; Yu, Jie; Zeng, Biyun
2015-03-01
To evaluate the efficacy of health education on patients with hip replacement based on the Internet, and to establish a new health education model through modern technology. A total of 300 patients with hip replacement from March to August, 2015 were enrolled in this study. The participants were divided into a control group and an experimental group according to months surgeries performed. Traditional education was applied in the control group while the multimedia source material plus the Internet platform of Joint Registration System were applied in the experimental group. Levels of anxiety, degree of satisfaction, and postoperative complications were analyzed. The levels of knowledge, attitude and behavior compliance in the patients of the experimental group were significantly improved, while the levels of postoperative anxiety were decreased compared with those in the control group (P<0.05). Education based on the Internet platform of Joint Registration System and the computer video could improve patients' knowledge, attitude, and behavior, which is worthy of clinical spread.
Thirteen-year outcomes in the Anatomique Benoist Girard II hip prosthesis.
Catanach, Michael J M; Sorial, Rami M; Eslick, Guy D
2015-04-01
The Stryker Anatomique Benoist Girard (ABG) hip implant system was a commonly used cementless prosthesis in the early 2000s, which fell from favour after several studies emerged implicating the prosthesis in high rates of revision. This retrospective, single-surgeon clinical study examines the fracture rate, revision rate and reasons for revision in 500 consecutive ABG II primary total conventional hip replacements. Follow-up was conducted by audit of patient notes, patient mailout survey, patient phone contact and audit of the Australian National Joint Replacement Registry (NJRR) database to find instances of fracture and revision. End points were periprosthetic fracture and revision for any reason. Follow-up was 1.2-13.8 years with a mean of 6.58 years. Of the 500 hips, 17 (3.4%) had undergone a revision. Of these, 13 were due to periprosthetic fracture. Four further fractures occurred that were not revised. Eight of these periprosthetic fractures occurred within 1 year post-operatively. There were four revisions for recurrent dislocations. Kaplan-Meier survival curve demonstrates a 93.7% survivorship at 6.58 years for revision for any reason. Multivariate analysis showed the only statistically significant factor for increased risk of revision was smaller stem size. Our results were consistent with the literature in that the ABG II system has good medium-term results but is prone to periprosthetic fractures, especially in the early post-operative period. When used as a primary total hip arthroplasty, the ABG II system has an 8-year revision rate of 5.6% compared with the 4.9% of all primary total hip arthroplasties. © 2014 Royal Australasian College of Surgeons.
Weidenhielm, Lars; Olivecrona, Henrik; Maguire, Gerald Q; Noz, Marilyn E
2018-06-01
This case report follows a woman who had a total hip replacement in 1992 when she was 45 years old. Six serial computed tomography (CT) examinations over a period of 13 years provided information that allowed her revision surgery to be limited to liner replacement as opposed to replacement of the entire prosthesis. Additionally, they provided data that ruled out the presence of osteolysis and indeed none was found at surgery. In 2004, when the first CT was performed, the 3D distance the femoral head had penetrated into the cup was determined to be 2.6 mm. By 2017, femoral head penetration had progressed to 5.0 mm. The extracted liner showed wear at the thinnest part to be 5.5 mm, as measured with a micrometer. The use of modern CT techniques can identify problems, while still correctable without major surgery. Furthermore, the ability of CT to assess the direction of wear revealed that the liner wear changed from the cranial to dorsal direction.
Sexual Function before and after Total Hip Replacement: Narrative Review
Meiri, Rotem; Rosenbaum, Talli Y; Kalichman, Leonid
2014-01-01
Background More than 1 million total hip replacements (THRs) are performed every year worldwide. Achieving decreased pain, increased mobility, and improved quality of life (QoL) are key factors in the decision to undergo THR. Sexual activity is a valued component of QoL; however, little is known about how THR affects sexual functioning or the extent to which health care providers address sexuality in THR patients. Aim The aim of the study was to assess the literature regarding sexuality and sexual function in patients before and after THR. Methods PubMed, Google Scholar, and PEDro databases were searched without search limitations from inception until December 2013 for terms relating to sexual function and THR. Results Sexual activity before and after a THR is an important QoL issue. In patients with end-stage hip osteoarthritis, THR has been reported to have beneficial effects in restoring sexual satisfaction and performance. While research has recently been conducted to determine the range of motion of the hip joints necessary to execute certain sexual positions, there remains a lack of validated guidelines and the risks related to sexual activity after THR is rarely discussed between patients and medical staff. Conclusions The ability to move comfortably is included among the many physical and psychosocial factors influencing sexual functioning. Practitioners should be encouraged to question their THR patients about sexual concerns and to provide counseling related to physical and functional aspects of sexual activity. Rehabilitation that focuses specifically on activities of daily living of sex should include sexual counseling, therapeutic exercise, and advice regarding sexual positions. Rehabilitation provided by physical therapists may help decrease pain, and facilitate greater self-awareness, self-confidence, and improved body image, all of which encourage and affirm optimal sexual health. Meiri R, Rosenbaum TY, and Kalichman L. Sexual function before and after total hip replacement: Narrative review. PMID:25548647
Satisfaction with joint replacement in public versus private hospitals: a cohort study.
Adie, Sam; Dao, Alan; Harris, Ian A; Naylor, Justine M; Mittal, Rajat
2012-09-01
In Australia, the majority of total knee and hip replacement surgeries occur in the private sector. Outcome-based research needs to be inclusive of this sector if the findings are intended to reflect the broader picture. This study compares outcomes up to 1 year post knee and hip replacement between patients treated in the public and private sectors. A prospective, observational study was performed in four high-volume joint replacement centres: two public, two private. Experienced orthopaedic surgeons contributed via their public and private practices. Knee and hip patients were recruited preoperatively. Self-reported questionnaires were completed preoperatively and at 6 and 12 months post-operatively. The primary outcome was satisfaction with surgery. Secondary outcomes included Oxford score, and SF-36 physical and mental component summary scores. Regression modelling was performed to adjust for potential confounders. Three hundred and thirty-one patients (184 public, 147 private; 215 knees, 116 hips) were recruited, with 6- and 12-month follow-up rates of 95% and 89%, respectively. Satisfaction rates were high in both public and private patients (approximately 90%) at 6 and 12 months, but private patients were less likely to be satisfied after adjusting for the strong effect of patient expectation. For both hip and knee cohorts, no between-sector differences were found in either the magnitude or rate of improvement in Oxford score or quality of life post-operatively. Joint replacement outcomes are similar for patients treated in public and private hospitals. Surgeons should manage patient expectation prior to surgery, particularly in private patients. © 2012 The Authors. ANZ Journal of Surgery © 2012 Royal Australasian College of Surgeons.
Reito, Aleksi; Elo, Petra; Nieminen, Jyrki; Puolakka, Timo; Eskelinen, Antti
2016-02-01
There are no international guidelines to define adverse reaction to metal debris (ARMD). Muscle fatty atrophy has been reported to be common in patients with failing metal-on-metal (MoM) hip replacements. We assessed whether gluteal muscle fatty atrophy is associated with elevated blood metal ion levels and pseudotumors. 263 consecutive patients with unilateral ASR XL total hip replacement using a posterior approach and with an unoperated contralateral hip were included in the study. All patients had undergone a standard screening program at our institution, including MRI and blood metal ion measurement. Muscle fatty atrophy was graded as being absent, mild, moderate, or severe in each of the gluteal muscles. The prevalence of moderate-to-severe gluteal muscle atrophy was low (12% for gluteus minimus, 10% for gluteus medius, and 2% for gluteus maximus). Muscle atrophy was neither associated with elevated blood metal ion levels (> 5 ppb) nor with the presence of a clear (solid- or mixed-type) pseudotumor seen in MRI. A combination of moderate-to-severe atrophy in MRI, elevated blood metal ion levels, and MRI-confirmed mixed or solid pseudotumor was rare. Multivariable regression revealed that "preoperative diagnosis other than osteoarthrosis" was the strongest predictor of the presence of fatty atrophy. Gluteal muscle atrophy may be a clinically significant finding with influence on hip muscle strength in patients with MoM hip replacement. However, our results suggest that gluteal muscle atrophy seen in MRI is not associated with either the presence or severity of ARMD, at least not in patients who have been operated on using the posterior approach.
Hip Resurfacing: An Alternative to Conventional Hip Replacement?
... and capped with a metal prosthesis. The hip socket is fitted with a metal cup. As these ... problem, but higher levels may be problematic. The socket prosthesis for a traditional hip replacement is usually ...
Tuberculosis of hip: A current concept review
Saraf, Shyam Kumar; Tuli, Surendra Mohan
2015-01-01
Tuberculosis (TB) of the hip is second to spine only hence a good number of cases are visiting the medical facilities every year. Many present in the advanced stage of the disease due to delayed diagnosis. In early stages of TB of hip, there is a diagnostic dilemma when plain X-rays are negative. In the present time, diagnostic modalities have improved from the days when diagnosis was based essentially on clinicoradiological presentation alone. By the time definite radiological changes appear on plain X-ray, the disease has moderately advanced. The modern diagnostic facilities like ultrasonography (USG) or magnetic resonance imaging of the hip joint, USG guided aspiration of synovial fluid and obtaining the material for polymerase chain reaction and tissue diagnosis must be utilized. In the treatment, current emphasis is more on mobility with stability at hip. Joint debridement, skeletal traction, and mobilization exercises may give more satisfying results as compared to the immobilization by hip spica. Adults with advanced arthritis and healed infection should be informed and discussed the various treatment modalities including the joint replacement. More and more surgeons are taking up the challenge of putting the total hip replacement in the active stage of the disease. Until the long term results in active disease are well established, we recommend it for the healed disease only in selected cases. PMID:25593352
Tuberculosis of hip: A current concept review.
Saraf, Shyam Kumar; Tuli, Surendra Mohan
2015-01-01
Tuberculosis (TB) of the hip is second to spine only hence a good number of cases are visiting the medical facilities every year. Many present in the advanced stage of the disease due to delayed diagnosis. In early stages of TB of hip, there is a diagnostic dilemma when plain X-rays are negative. In the present time, diagnostic modalities have improved from the days when diagnosis was based essentially on clinicoradiological presentation alone. By the time definite radiological changes appear on plain X-ray, the disease has moderately advanced. The modern diagnostic facilities like ultrasonography (USG) or magnetic resonance imaging of the hip joint, USG guided aspiration of synovial fluid and obtaining the material for polymerase chain reaction and tissue diagnosis must be utilized. In the treatment, current emphasis is more on mobility with stability at hip. Joint debridement, skeletal traction, and mobilization exercises may give more satisfying results as compared to the immobilization by hip spica. Adults with advanced arthritis and healed infection should be informed and discussed the various treatment modalities including the joint replacement. More and more surgeons are taking up the challenge of putting the total hip replacement in the active stage of the disease. Until the long term results in active disease are well established, we recommend it for the healed disease only in selected cases.
How much arthritis is too much for hip arthroscopy: a systematic review.
Domb, Benjamin G; Gui, Chengcheng; Lodhia, Parth
2015-03-01
The purpose of this study was to determine the extent of preoperative osteoarthritis (OA) that precludes benefit from hip arthroscopy by systematically reviewing the literature on hip arthroscopy in the setting of OA. We searched the Medline and PubMed databases using the following Medical Subject Heading terms: arthritis, osteoarthritis, chondral damage, chondral injury, chondral delamination, and hip arthroscopy. Two authors independently reviewed the literature and included articles if they were in the English language; commented on preoperative factors, parameters, physical examination, or diagnostic testing that may be evidence of cartilage damage and/or arthritis; contained outcome data on patients undergoing hip arthroscopy; and had a sample size of at least 10 patients with arthritic changes in the hip. We excluded review articles, technique articles, articles with overlapping patient populations, articles with hip arthroscopy used as an adjunct to an open procedure, articles with inflammatory and septic arthritis, and articles with a mean age younger than 18 years. Our search identified 518 articles, of which 15 met the inclusion and exclusion criteria. Two thousand fifty-one hips underwent arthroscopy at a mean patient age of 40.2 years. Of these, 1,195 hips had signs of OA. There were 345 conversions to total hip arthroplasty/surface replacement arthroplasty. Of these patients, 274 had OA. Eight patient-reported outcome instruments were used. Factors influencing outcomes were preoperative OA, age, chondral damage, femoroacetabular impingement, and duration of symptoms. Current evidence is insufficient to define a cutoff for how much arthritis is too much for hip arthroscopy. However, this analysis shows that patients with a Tönnis grade of 1 or greater or a joint space of 2 mm or less are less likely to benefit from hip arthroscopy and more likely to require conversion to total hip arthroplasty/surface replacement arthroplasty. Postoperative scores on patient-reported outcome instruments are lower in the arthritic population at follow-up compared with their nonarthritic counterparts. Level IV, systematic review of Level III and IV studies. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Cognitive dysfunction after fast-track hip and knee replacement.
Krenk, Lene; Kehlet, Henrik; Bæk Hansen, Torben; Solgaard, Søren; Soballe, Kjeld; Rasmussen, Lars Simon
2014-05-01
Postoperative cognitive dysfunction (POCD) is reported to occur after major surgery in as many as 20% of patients, elderly patients may especially experience problems in the weeks and months after surgery. Recent studies vary greatly in methods of evaluation and diagnosis of POCD, and the pathogenic mechanisms are still unclear. We evaluated a large uniform cohort of elderly patients in a standardized approach, after major joint replacement surgery (total hip and knee replacement). Patients were in an optimized perioperative approach (fast track) with multimodal opioid-sparing analgesia, early mobilization, and short length of stay (LOS ≤3 days) and discharged to home. In a prospective multicenter study, we included 225 patients aged ≥60 years undergoing well-defined fast-track total hip or total knee replacement. Patients had neuropsychological testing preoperatively and 1 to 2 weeks and 3 months postoperatively. LOS, pain, opioid use, inflammatory response, and sleep quality were recorded. The practice effect of repeated cognitive testing was gauged using data from a healthy community-dwelling control group (n = 161). Median LOS was 2 days (interquartile range 2-3). The incidence of POCD at 1 to 2 weeks was 9.1% (95% confidence interval [CI], 5.4%-13.1%) and 8.0% (95% CI, 4.5%-12.0%) at 3 months. There was no statistically significant difference between patients with and without early POCD, regarding pain, opioid use, sleep quality, or C-reactive protein response, although the CIs were wide. Patients with early POCD had a higher Mini Mental State Examination score preoperatively (difference in medians 0.5 [95% CI, -1.0% to 0.0%]; P = 0.034). If there was an association between early POCD and late POCD, the sample size was unfortunately too small to verify this (23.6% of patients with early POCD had late onset vs 6.7% in non-POCD group; risk difference 16.9 (95% CI, -2.1% to 41.1%; P = 0.089). The incidence of POCD early after total hip and knee replacement seems to be lower after a fast-track approach than rates previously reported for these procedures, but late POCD occurred with an incidence similar to that in previous studies of major noncardiac elective surgery. No association between early and late POCD could be verified.
Wallis, Jason A; Taylor, Nicholas F
2011-12-01
To determine if pre-operative interventions for hip and knee osteoarthritis provide benefit before and after joint replacement. Systematic review with meta-analysis of randomised controlled trials (RCTs) of pre-operative interventions for people with hip or knee osteoarthritis awaiting joint replacement surgery. Standardised mean differences (SMD) were calculated for pain, musculoskeletal impairment, activity limitation, quality of life, and health service utilisation (length of stay and discharge destination). The GRADE approach was used to determine the quality of the evidence. Twenty-three RCTs involving 1461 participants awaiting hip or knee replacement surgery were identified. Meta-analysis provided moderate quality evidence that pre-operative exercise interventions for knee osteoarthritis reduced pain prior to knee replacement surgery (SMD (95% CI)=0.43 [0.13, 0.73]). None of the other meta-analyses investigating pre-operative interventions for knee osteoarthritis demonstrated any effect. Meta-analyses provided low to moderate quality evidence that exercise interventions for hip osteoarthritis reduced pain (SMD (95% CI)=0.52 [0.04, 1.01]) and improved activity (SMD (95% CI)=0.47 [0.11, 0.83]) prior to hip replacement surgery. Meta-analyses provided low quality evidence that exercise with education programs improved activity after hip replacement with reduced time to reach functional milestones during hospital stay (e.g., SMD (95% CI)=0.50 [0.10, 0.90] for first day walking). Low to moderate evidence from mostly small RCTs demonstrated that pre-operative interventions, particularly exercise, reduce pain for patients with hip and knee osteoarthritis prior to joint replacement, and exercise with education programs may improve activity after hip replacement. Copyright © 2011 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Talia, Adrian J; Coetzee, Cassandra; Tirosh, Oren; Tran, Phong
2018-01-08
Total hip arthroplasty is one of the most commonly performed surgical procedures worldwide. There are a number of surgical approaches for total hip arthroplasty and no high-level evidence supporting one approach over the other. Each approach has its unique benefits and drawbacks. This trial aims to directly compare the three most common surgical approaches for total hip arthroplasty. This is a single-centre study conducted at Western Health, Melbourne, Australia; a large metropolitan centre. It is a pragmatic, parallel three-arm, randomised controlled trial. Sample size will be 243 participants (81 in each group). Randomisation will be secure, web-based and managed by an independent statistician. Patients and research team will be blinded pre-operatively, but not post-operatively. Intervention will be either direct anterior, lateral or posterior approach for total hip arthroplasty, and the three arms will be directly compared. Participants will be aged over 18 years, able to provide informed consent and recruited from our outpatients. Patients who are having revision surgery or have indications for hip replacement other than osteoarthritis (i.e., fracture, malignancy, development dysplasia) will be excluded from the trial. The Oxford Hip Score will be determined for patients pre-operatively and 6 weeks, 6, 12 and 24 months post-operatively. The Oxford Hip Score at 24 months will be the primary outcome measure. Secondary outcome measures will be dislocation, infection, intraoperative and peri-prosthetic fracture rate, length of hospital stay and pain level, reported using a visual analogue scale. Many studies have evaluated approaches for total hip arthroplasty and arthroplasty registries worldwide are now collecting this data. However no study to date has compared these three common approaches directly in a randomised fashion. No trial has used patient-reported outcome measures to evaluate success. This pragmatic study aims to identify differences in patient perception of total hip arthroplasty depending on surgical approach. Australian New Zealand Clinical Trials Registry, ACTRN12617000272392 . Registered on 22 February 2017.
Tribological characteristics of a composite total-surface hip replacement
NASA Technical Reports Server (NTRS)
Jones, W. R., Jr.; Roberts, J. C.; Ling, F. F.
1982-01-01
Continuous fiber, woven E glass composite femoral shells having the same elastic properties as bone were fabricated. The shells were then encrusted with filled epoxy wear resistant coatings and run dry against ultrahigh molecular weight polyethylene acetabular cups in 42,000 and 250,000 cycle wear tests on a total hip simulator. The tribological characteristics of these continuous fiber particulate composite femoral shells articulating with ultrahigh molecular weight polyethylene acetabular cups were comparable to those of a vitallium ball articulating with an ultrahigh molecular weight polyethylene acetabular cup.
Transfusions and blood loss in total hip and knee arthroplasty: a prospective observational study.
Carling, Malin S; Jeppsson, Anders; Eriksson, Bengt I; Brisby, Helena
2015-03-28
There is a high prevalence of blood product transfusions in orthopedic surgery. The reported prevalence of red blood cell transfusions in unselected patients undergoing hip or knee replacement varies between 21% and 70%. We determined current blood loss and transfusion prevalence in total hip and knee arthroplasty when tranexamic acid was used as a routine prophylaxis, and further investigated potential predictors for excessive blood loss and transfusion requirement. In total, 193 consecutive patients undergoing unilateral hip (n = 114) or knee arthroplasty (n = 79) were included in a prospective observational study. Estimated perioperative blood loss was calculated and transfusions of allogeneic blood products registered and related to patient characteristics and perioperative variables. Overall transfusion rate was 16% (18% in hip patients and 11% in knee patients, p = 0.19). Median estimated blood loss was significantly higher in hip patients (984 vs 789 mL, p < 0.001). Preoperative hemoglobin concentration was the only independent predictor of red blood cell transfusion in hip patients while low hemoglobin concentration, body mass index, and operation time were independent predictors for red blood cell transfusion in knee patients. The prevalence of red blood cell transfusion was lower than previously reported in unselected total hip or knee arthroplasty patients. Routine use of tranexamic acid may have contributed. Low preoperative hemoglobin levels, low body mass index, and long operation increase the risk for red blood cell transfusion.
Jepson, Paul; Sands, Gina; Beswick, Andrew D; Davis, Edward T; Blom, Ashley W; Sackley, Catherine M
2016-02-01
To assess the feasibility of a pre-operative occupational therapy intervention for patients undergoing primary total hip replacement. Single blinded feasibility randomised controlled trial, with data collection prior to the intervention, and at 4, 12, and 26 weeks following surgery. Recruitment from two NHS orthopaedic outpatient centres in the West Midlands, UK. Patients awaiting primary total hip replacement due to osteoarthritis were recruited. Following pre-operative assessment, patients were individually randomised to intervention or control by a computer-generated block randomisation algorithm stratified by age and centre. The intervention group received a pre-surgery home visit by an occupational therapist who discussed expectations, assessed home safety, and provided appropriate adaptive equipment. The control group received treatment as usual. The study assessed the feasibility of recruitment procedures, delivery of the intervention, appropriateness of outcome measures and data collection methods. Health related quality of life and resource use were recorded at 4, 12 and 26 weeks. Forty-four participants were recruited, 21 were randomised to the occupational therapy intervention and 23 to usual care. Analysis of 26 week data included 18 participants in the intervention group and 21 in the control. The intervention was delivered successfully with no withdrawals or crossovers; 5/44 were lost to follow-up with further missing data for participation and resource use. The feasibility study provided the information required to conduct a definitive trial. Burden of assessment would need to be addressed. A total of 219 patients would be required in an efficacy trial. © The Author(s) 2015.
Na, H S; Shin, H J; Lee, Y J; Kim, J H; Koo, K H; Do, S H
2016-01-01
We evaluated changes in rotational thromboelastometry (ROTEM(®) ) parameters and clinical outcomes in patients undergoing total hip replacement arthroplasty, with concomitant infusions of tranexamic acid and of 6% hydroxyethyl starch 130/0.4. Fifty-five patients were randomly assigned to either the tranexamic acid (n = 29) or the control (n = 26) group. Hydroxyethyl starch was administered in the range of 10-15 ml.kg(-1) during the operation in both groups. In the control group, the clot formation time and maximum clot firmness of APTEM showed significant differences when compared with those of EXTEM at one hour postoperatively, suggestive of fibrinolysis. In the tranexamic acid group, there was no significant difference between each postoperative EXTEM and APTEM parameter. In the tranexamic acid and control group, postoperative blood loss was 308 ml (210-420 [106-745]) and 488 ml (375-620 [170-910], p = 0.002), respectively, and total blood loss was 1168 ml (922-1470 [663-2107]) and 1563 ml (1276-1708 [887-1494], p = 0.003). Haemoglobin concentration was higher in the tranexamic acid group on the second postoperative day (10.5 (9.4-12.1 [7.9-14.0]) vs. 9.6 (8.9-10.5[7.3-16.0]) g.dl(-1) , p = 0.027). In patients undergoing total hip replacement arthroplasty, postoperative fibrinolysis aggravated by hydroxyethyl starch was attenuated by co-administration of 10 mg.kg(-1) tranexamic acid, which may have led to less postoperative blood loss. © 2015 The Association of Anaesthetists of Great Britain and Ireland.
Corrosion and Tribology of Materials Used in a Novel Reverse Hip Replacement.
Braddon, Linda; Termanini, Zafer; MacDonald, Steven; Parvizi, Jay; Lieberman, Jay; Frankel, Victor; Zuckerman, Joseph
2017-07-05
Total hip arthroplasty has been utilized for the past 50 years as an effective treatment for degenerative, inflammatory and traumatic disorders of the hip. The design of these implants has generally followed the anatomy of the hip as a ball and socket joint with the femoral head representing the ball and the acetabulum representing the socket. We describe a novel hip arthroplasty design in which the "ball" is located on the acetabular side and the "socket" is located on the femoral side. The results of extensive biomechanical testing are described and document wear and corrosion characteristics that are at least equivalent to standard designs. These results support clinical assessment as the next step of the evaluation.
Corrosion and Tribology of Materials Used in a Novel Reverse Hip Replacement
Braddon, Linda; Termanini, Zafer; MacDonald, Steven; Parvizi, Jay; Lieberman, Jay; Frankel, Victor; Zuckerman, Joseph
2017-01-01
Total hip arthroplasty has been utilized for the past 50 years as an effective treatment for degenerative, inflammatory and traumatic disorders of the hip. The design of these implants has generally followed the anatomy of the hip as a ball and socket joint with the femoral head representing the ball and the acetabulum representing the socket. We describe a novel hip arthroplasty design in which the “ball” is located on the acetabular side and the “socket” is located on the femoral side. The results of extensive biomechanical testing are described and document wear and corrosion characteristics that are at least equivalent to standard designs. These results support clinical assessment as the next step of the evaluation. PMID:28773112
2011-01-01
Background There is emerging evidence for a beneficial effect of meat consumption on the musculoskeletal system. However, whether it affects the risk of knee and hip osteoarthritis is unknown. We performed a prospective cohort study to examine the relationship between meat consumption and risk of primary hip and knee replacement for osteoarthritis. Methods Eligible 35,331 participants were selected from the Melbourne Collaborative Cohort Study recruited during 1990-1994. Consumption of fresh red meat, processed meat, chicken, and fish was assessed using a food frequency questionnaire. Primary hip and knee replacement for osteoarthritis during 2001-2005 was determined by linking the cohort records to the Australian National Joint Replacement Registry. Results There was a negative dose-response relationship between fresh red meat consumption and the risk of hip replacement (hazard ratio (HR) 0.94 per increase in intake of one time/week, 95% confidence interval (CI) 0.89-0.98). In contrast, there was no association with knee replacement risk (HR 0.98, 95% CI 0.94-1.02). Consumption of processed meat, chicken and fish were not associated with risk of hip or knee replacement. Conclusion A high level consumption of fresh red meat was associated with a decreased risk of hip, but not knee, joint replacement for osteoarthritis. One possible mechanism to explain these differential associations may be via an effect of meat intake on bone strength and hip shape. Further confirmatory studies are warranted. PMID:21235820
Wang, Yuanyuan; Simpson, Julie Anne; Wluka, Anita E; English, Dallas R; Giles, Graham G; Graves, Stephen; Cicuttini, Flavia M
2011-01-16
There is emerging evidence for a beneficial effect of meat consumption on the musculoskeletal system. However, whether it affects the risk of knee and hip osteoarthritis is unknown. We performed a prospective cohort study to examine the relationship between meat consumption and risk of primary hip and knee replacement for osteoarthritis. Eligible 35,331 participants were selected from the Melbourne Collaborative Cohort Study recruited during 1990-1994. Consumption of fresh red meat, processed meat, chicken, and fish was assessed using a food frequency questionnaire. Primary hip and knee replacement for osteoarthritis during 2001-2005 was determined by linking the cohort records to the Australian National Joint Replacement Registry. There was a negative dose-response relationship between fresh red meat consumption and the risk of hip replacement (hazard ratio (HR) 0.94 per increase in intake of one time/week, 95% confidence interval (CI) 0.89-0.98). In contrast, there was no association with knee replacement risk (HR 0.98, 95% CI 0.94-1.02). Consumption of processed meat, chicken and fish were not associated with risk of hip or knee replacement. A high level consumption of fresh red meat was associated with a decreased risk of hip, but not knee, joint replacement for osteoarthritis. One possible mechanism to explain these differential associations may be via an effect of meat intake on bone strength and hip shape. Further confirmatory studies are warranted.
Hip or knee replacement - in the hospital after
Hip replacement surgery - after - self-care; Knee replacement surgery - after - self-care ... taking walks in the hallways with help. After knee replacement, some surgeons recommend using a continuous passive ...
Brennan, Sharon L; Stanford, Tyman; Wluka, Anita E; Henry, Margaret J; Page, Richard S; Graves, Stephen E; Kotowicz, Mark A; Nicholson, Geoffrey C; Pasco, Julie A
2012-04-30
The utilization of total hip replacement (THR) surgery is rapidly increasing, however few data examine whether these procedures are associated with socioeconomic status (SES) within Australia. This study examined primary THR across SES for both genders for the Barwon Statistical Division (BSD) of Victoria, Australia. Using the Australian Orthopaedic Association National Joint Replacement Registry data for 2006-7, primary THR with a diagnosis of osteoarthritis (OA) among residents of the BSD was ascertained. The Index of Relative Socioeconomic Disadvantage was used to measure SES; determined by matching residential addresses with Australian Bureau of Statistics census data. The data were categorised into quintiles; quintile 1 indicating the most disadvantaged. Age- and sex-specific rates of primary THR per 1,000 person years were reported for 10-year age bands using the total population at risk. Females accounted for 46.9% of the 642 primary THR performed during 2006-7. THR utilization per 1,000 person years was 1.9 for males and 1.5 for females. The highest utilization of primary THR was observed in those aged 70-79 years (males 6.1, and females 5.4 per 1,000 person years). Overall, the U-shaped pattern of THR across SES gave the appearance of bimodality for both males and females, whereby rates were greater for both the most disadvantaged and least disadvantaged groups. Further work on a larger scale is required to determine whether relationships between SES and THR utilization for the diagnosis of OA is attributable to lifestyle factors related to SES, or alternatively reflects geographic and health system biases. Identifying contributing factors associated with SES may enhance resource planning and enable more effective and focussed preventive strategies for hip OA.
Recent Patents and Designs on Hip Replacement Prostheses
Derar, H; Shahinpoor, M
2015-01-01
Hip replacement surgery has gone through tremendous evolution since the first procedure in 1840. In the past five decades the advances that have been made in technology, advanced and smart materials innovations, surgical techniques, robotic surgery and methods of fixations and sterilization, facilitated hip implants that undergo multiple design revolutions seeking the least problematic implants and a longer survivorship. Hip surgery has become a solution for many in need of hip joint remedy and replacement across the globe. Nevertheless, there are still long-term problems that are essential to search and resolve to find the optimum implant. This paper reviews several recent patents on hip replacement surgery. The patents present various designs of prostheses, different materials as well as methods of fixation. Each of the patents presents a new design as a solution to different issues ranging from the longevity of the hip prostheses to discomfort and inconvenience experienced by patients in the long-term. PMID:25893020
Primary total hip replacement versus hip resurfacing - hospital considerations.
Ward, William G; Carter, Christina J; Barone, Marisa; Jinnah, Riyaz
2011-01-01
Multiple factors regarding surgical procedures and patient selection affect hospital staffing needs as well as hospital revenues. In order to better understand the potential impact on hospitals that hip arthroplasty device selection (standard total hip arthroplasty vs. resurfacing) creates, a review of all primary hip arthroplasties performed at one institution was designed to identify factors that impacted hospital staffing needs and revenue generation. All primary hip arthroplasties undertaken over three fiscal years (2008 to 2010) were reviewed, utilizing only hospital business office data and medical records data that had been previously extracted prior for billing purposes. Analysis confirmed differing demographics for two hip arthroplasty populations, with the resurfacing patients (compared to the conventional total hip arthroplasty population) consisting of younger patients (mean age, 50 vs. 61 years), who were more often male (75% vs. 45%), were more likely to have osteoarthritis as their primary diagnosis (83 vs. 67%) and were more often covered by managed care or commercial insurance (83 vs. 34%). They also had shorter hospital stays (mean length of stay, 2.3 vs. 4.1 days) and consequently provided a more favorable financial revenue stream to the hospital on a per patient basis. Several trends appeared during the study periods. There was a steady increase in all procedures in all groups except for the resurfacings, which decreased 26% in males and 53% in females between 2009 and 2010. Differences were observed in the demographics of patients presenting for resurfacing, compared to those presenting for conventional total hip arthroplasty. In addition to the revenue stream considerations, institutions undertaking a resurfacing program must commit the resources and planning in order to rehabilitate these patients more expeditiously than is usually required with conventional hip arthroplasty patients.
Reito, Aleksi; Lainiala, Olli; Elo, Petra; Eskelinen, Antti
2016-01-01
Metal-on-metal (MoM) hip replacements were used for almost a decade before adverse reactions to metal debris (ARMD) were found to be a true clinical problem. Currently, there is a paucity of evidence regarding the usefulness of systematic screening for ARMD. We implemented a systematic review and meta-analysis to establish the prevalence of revision confirmed ARMD stratified by the use of different screening protocols in patients with MoM hip replacements. Five levels of screening were identified: no screening (level 0), targeted blood metal ion measurement and/or cross-sectional imaging (level 1), metal ion measurement without imaging (level 2), metal ion measurement with targeted imaging (level 3) and comprehensive screening (both metal ions and imaging for all; level 4). 122 studies meeting our eligibility criteria were included in analysis. These studies included 144 study arms: 100 study arms with hip resurfacings, 33 study arms with large-diameter MoM total hip replacements (THR), and 11 study arms with medium-diameter MoM THRs. For hip resurfacing, the lowest prevalence of ARMD was seen with level 0 screening (pooled prevalence 0.13%) and the highest with level 4 screening (pooled prevalace 9.49%). Pooled prevalence of ARMD with level 0 screening was 0.29% and with level 4 screening 21.3% in the large-diameter MoM THR group. In metaregression analysis of hip resurfacings, level 4 screening was superior with regard to prevalence of ARMD when compared with other levels. In the large diameter THR group level 4 screening was superior to screening 0,2 and 3. These outcomes were irrespective of follow-up time or study publication year. With hip resurfacings, routine cross-sectional imaging regardless of clinical findings is advisable. It is clear, however, that targeted metal ion measurement and/or imaging is not sufficient in the screening for ARMD in any implant concepts. However, economic aspects should be weighed when choosing the preferred screening level. PMID:26930057
van der Linde, M J; Tonino, A J
1997-12-01
In 600 consecutive uncemented total hip replacements, 2 surgical approaches were used: the direct lateral Hardinge approach in supine position (group I: 241 cases) or in a lateral position (group II: 280 cases) and the anterolateral Watson-Jones approach in supine position (group III: 79 cases). 5 patients had clinically evident peripheral nerve injuries confirmed with EMG: none in group I, 1 lesion of the nervus ischiadicus and nervus femoralis in group II and 4 nervus femoralis lesions in group III, of which 1 was combined with an obturator nerve injury. The nerve injuries were evaluated with EMG. All 4 nervus femoralis lesions recovered spontaneously, but the one patients in group II had a persistent palsy of the peroneal nerve. The anatomical basis for the higher prevalence of nervus femoralis lesions in the anterolateral Watson-Jones approach is described.
Radl, Roman; Hungerford, Marc; Materna, Wilfried; Rehak, Peter; Windhager, Reinhard
2005-02-01
Several authors have found poorer outcome after hip replacement for osteonecrosis than after hip replacement for arthrosis. In a retrospective study we evaluated the performance of an uncemented femoral component in patients with osteonecrosis and arthrosis of the hip. 31 patients operated for osteonecrosis, and 49 patients operated for osteoarthrosis were included. The median follow-up time was 6.1 (2-11) years for the patients with osteonecrosis, and 5.9 (4-8) for the arthrosis patients. Migration analysis performed by the Einzel-Bild-Roentgen Analysis (EBRA) technique revealed a median stem migration of 1.5 (-8.8-0) mm in the patients with osteonecrosis, but only 0.6 (-2.8-0.7) mm in the patients with arthrosis (p < 0.001). Survivorship analysis with stem revision as endpoint for failure was 74% (95% CI: 55-94) in the osteonecrosis, and 98% (95% CI: 94-100) in the arthrosis group (p = 0.01). We suggest that the higher failure rate and stem migration of uncemented total hip replacement in the patients with osteonecrosis is a consequence of the disease. On the basis of these findings, we recommend close monitoring of the patients with osteonecrosis, which should include migration measurements.
Hip joint replacement - slideshow
... this page: //medlineplus.gov/ency/presentations/100006.htm Hip joint replacement - series—Normal anatomy To use the ... to slide 5 out of 5 Overview The hip joint is made up of two major parts: ...
Hip joint replacement using monofilament polypropylene surgical mesh: an animal model.
Białecki, Jacek; Majchrzycki, Marian; Szymczak, Antoni; Klimowicz-Bodys, Małgorzata Dorota; Wierzchoś, Edward; Kołomecki, Krzysztof
2014-01-01
Hip joint dysplasia is a deformation of the articular elements (pelvic acetabulum, head of the femur, and/or ligament of the head of the femur) leading to laxity of the hip components and dislocation of the femoral head from the pelvic acetabulum. Diagnosis is based on symptoms observed during clinical and radiological examinations. There are two treatment options: conservative and surgical. The classic surgical procedures are juvenile pubic symphysiodesis (JPS), triple pelvic osteotomy (TPO), total hip replacement (THR), and femoral head and neck resection (FHNE). The aim of this experiment was to present an original technique of filling the acetabulum with a polypropylene implant, resting the femoral neck directly on the mesh. The experiment was performed on eight sheep. The clinical value of the new surgical technique was evaluated using clinical, radiological, and histological methods. This technique helps decrease the loss of limb length by supporting the femoral neck on the mesh equivalent to the femoral head. It also reduces joint pain and leads to the formation of stable and mobile pseudarthrosis. The mesh manifested osteoprotective properties and enabled the formation of a stiff-elastic connection within the hip joint. The method is very cost-effective and the technique itself is simple to perform.
Prospective study on serum metal levels in patients with metal-on-metal lumbar disc arthroplasty.
Gornet, Matthew F; Burkus, J K; Harper, M L; Chan, F W; Skipor, A K; Jacobs, J J
2013-04-01
Metal-on-metal total disc replacement is a recent alternative treatment for degenerative disc disease. Wear and corrosion of these implants can lead to local and systemic transport of metal debris. This prospective longitudinal study examined the serum chromium and cobalt levels in 24 patients with cobalt-chromium alloy metal-on-metal lumbar disc replacements. Serum was assayed for chromium (Cr) and cobalt (Co) using high-resolution inductively-coupled plasma-mass spectrometry. Detection limits were 0.015 ng/mL for Cr and 0.04 ng/mL for Co. Median serum Co levels at pre-op, 3, 6, 12, 24, and 36-months post-op were 0.10, 1.03, 0.96, 0.98, 0.67, and 0.52 ng/mL, respectively. Median serum Cr levels were 0.06, 0.49, 0.65, 0.43, 0.52, and 0.50 ng/mL, respectively. In general, these results indicated that serum Co and Cr levels are elevated at all postoperative time points and are of the same order of magnitude as those observed in well-functioning metal-on-metal surface replacements of the hip and in metal-on-metal total hip replacements at similar postoperative time points.
Becker, B S; Bolton, J D
1997-12-01
Artificial hip joints have an average lifetime of 10 years due to aseptic loosening of the femoral stem attributed to polymeric wear debris; however, there is a steadily increasing demand from younger osteoarthritis patients aged between 15 and 40 year for a longer lasting joint of 25 years or more. Compliant layers incorporated into the acetabular cup generate elastohydrodynamic lubrication conditions between the bearing surfaces, reduce joint friction coefficients and wear debris production and could increase the average life of total hip replacements, and other human load-bearing joint replacements, i.e. total knee replacements. Poor adhesion between a fully dense substrate and the compliant layer has so far prevented any further exploitation. This work investigated the possibility of producing porous metallic, functionally gradient type acetabular cups using powder metallurgy techniques - where a porous surface was supported by a denser core - into which the compliant layers could be incorporated. The corrosion behaviour and mechanical properties of three biomedically approved alloys containing two levels of total porosity (>30% and <10%) were established, resulting in Ti-6Al-4V being identified as the most promising biocompatible functionally graded material, not only for this application but for other hard-tissue implants.
Economic Analysis of 4221 Revisions Due to Periprosthetic Joint Infection in Poland.
Babiak, Ireneusz; Pędzisz, Piotr; Janowicz, Jakub; Kulig, Mateusz; Małdyk, Paweł
2017-01-26
Periprosthetic joint infection (PJI) is one of the most severe complications of total hip (THA) and total knee (TKA) arthroplasty. The aim of the study is to determine the number and type of hip and knee prosthesis revisions in Poland performed due to infection and reimbursement of the cost of septic revisions and to compare the costs of septic and aseptic revisions in Poland and other countries. The data published for the period 2009-2013 by the National Health Fund (NHF) were analysed and the average cost of septic and aseptic revisions was calculated. In the years 2009-2013, a total of 260,030 hip and knee arthroplasties including 23,027 revisions (incl. 4,221 septic) were performed in Poland. In 2013, septic revisions accounted for 1.38% of all hip replacement procedures, 2.56% of all knee replacement procedures and 14.67% of all hip revisions and 30.23% of all knee revisions. In 2013, the difference between the average cost incurred by the hospital and the NHF refund for septic revision due to PJI was at least €238 and the cost-refund gap for the entire year was €219198. 1. The system of reporting periprostheticjoint infections currently in use in Poland does not adequately reflect the current classification of PJI and reimbursement for septic revision of joint prosthesis does not match the actual costs. 2. The Polish DRG system does not distinguish between early and late PJI and fails to acknowledge basic guidelines for infection treatment currently followed in Poland and worldwide. 3. According to the DRG system, patients requiring different treatment are placed in one category. 4. Until the year 2013, the less expensive treatment of early infections had been reimbursed on the same basis as the more costly two-stage revision procedures.
Chammout, Ghazi; Muren, Olle; Laurencikas, Evaldas; Bodén, Henrik; Kelly-Pettersson, Paula; Sjöö, Helene; Stark, André; Sköldenberg, Olof
2017-01-01
Background and purpose Total hip replacement (THR) is the preferred method for the active and lucid elderly patient with a displaced femoral neck fracture (FNF). Controversy still exists regarding the use of cemented or uncemented stems in these patients. We compared the effectiveness and safety between a modern cemented, and a modern uncemented hydroxyapatite-coated femoral stem in patients 65–79 years of age who were treated with THR for displaced FNF. Patients and methods In a single-center, single-blinded randomized controlled trial, we included 69 patients, mean age 75 (65–79) and with a displaced FNF (Garden III–IV). 35 patients were randomized to a cemented THR and 34 to a reverse-hybrid THR with an uncemented stem. Primary endpoints were: prevalence of all hip-related complications and health-related quality of life, evaluated with EuroQol-5D (EQ-5D) index up to 2 years after surgery. Secondary outcomes included: overall mortality, general medical complications, and hip function. The patients were followed up at 3, 12, and 24 months. Results According to the calculation of sample size, 140 patients would be required for the primary endpoints, but the study was stopped when only half of the sample size was included (n = 69). An interim analysis at that time showed that the total number of early hip-related complications was substantially higher in the uncemented group, 9 (among them, 3 dislocations and 4 periprosthetic fractures) as compared to 1 in the cemented group. The mortality and functional outcome scores were similar in the 2 groups. Interpretation We do not recommend uncemented femoral stems for the treatment of elderly patients with displaced FNFs. PMID:27967333
Lecerf, G; Fessy, M H; Philippot, R; Massin, P; Giraud, F; Flecher, X; Girard, J; Mertl, P; Marchetti, E; Stindel, E
2009-05-01
BACKGROUND OBJECTIVE: Femoral offset is supposed to influence the results of hip replacement but little is known about the accurate method of measure and the true effect of offset modifications. This article is a collection of independent anatomic, radiological and clinical works, which purpose is to assess knowledge of the implications of femoral offset for preoperative templating and total hip arthroplasty. There is a strong correlation between femoral offset, abductors lever arm and hip abductor strength. Hip lateralization is independent of the femoral endomedullary characteristics. The abductors lever arm is highly correlated to the gluteus medius activation angle. There were correlations between femoral offset and endomedullary shape. The hip center was high and medial for stovepipe metaphysis while it was lower and lateralized for champagne - flute upper femur. A study was performed to compare the femoral offset measured by X-ray and CT-scan in 50 patients, demonstrated that plain radiography underestimates offset measurement. The 2D templating cannot appreciate the rotation of the lower limb. Taking into account the horizontal plane is essential to obtain proper 3D planning of the femoral offset. A randomized study was designed to compare femoral offset measurements after hip resurfacing and total hip arthroplasty. This study underlined hip resurfacing reduced the femoral offset, while hip replacement increased offset. However, the reduction of femoral offset after hip resurfacing does not affect the function. A pilot study was designed to assess the results of 120 hip arthroplasties with a modular femoral neck. This study showed that the use of a modular collar ensures an easier restoration of the femoral offset. A cohort of high offset stems (Lubinus 117 degrees) was retrospectively assessed. The survival rate was slightly lower that the standard design reported in the Swedish register. Finally, the measurement of offset and leg length was assessed with the help of computer assistance. The software changed the initial schedule (obtained by templating) in 29%. Therefore, femoral offset restoration is essential to improve function and longevity of hip arthroplasty. CT-scan is more accurate than plain radiography to assess femoral offset. Hip resurfacing decreases offset without effect on function. Modular neck and computer assistance may improve intraoperative calculation and reproduction of femoral offset. Increasing offset with a standard cemented design may decrease long-term fixation. Level IV: Retrospective or historical series.
Weeks, William B; Schoellkopf, William J; Ballard, David J; Kaplan, Gary S; James, Brent; Weinstein, James N
2017-06-01
To inform consumers and restrain health care cost growth, efforts to promote transparency and to reimburse for care episodes are accelerating in the United States. To compare characteristics and costs of 30-day episode of care for hip and knee replacement occurring in High Value Healthcare Collaborative (HVHC)-member hospitals to those occurring in like non-HVHC-member hospitals in the same 15 health care markets before interventions by HVHC members to improve health care value for those interventions. This is a retrospective analysis of fee-for-service Medicare data from 2012 and 2013. For hip arthroplasty, 4030 HVHC-member and 7572 non-HVHC-member, and for knee arthroplasty, 6542 HVHC-member and 13,900 non-HVHC-member fee-for-service Medicare patients aged 65 and older. Volumes, patient demographics, hospital stay characteristics, and acute and postacute care standardized costs for a 30-day episode of care. HVHC-member hospitals differed from similar non-HVHC-member hospitals in the same health care markets when considering volumes of surgeries, patient demographics, Charlson scores, and patient distance to care during the index admission. There was little variation in acute care costs of hip or knee replacement surgery across health care markets; however, there was substantial variation in postacute care costs across those same markets. We saw less variation in postacute care costs within markets than across markets. Regression analyses showed that HVHC-member status was not associated with shorter lengths of stay, different complication rates, or lower total or postacute care costs for hip or knee replacement. Health care regions appear to be a more important predictor of episode costs of care than HVHC status.
Characterization and tribology of PEG-like coatings on UHMWPE for total hip replacements.
Kane, Sheryl R; Ashby, Paul D; Pruitt, Lisa A
2010-03-15
A crosslinked hydrogel coating similar to poly(ethylene glycol) (PEG) was covalently bonded to the surface of ultrahigh molecular weight polyethylene (UHMWPE) to improve the lubricity and wear resistance of the UHWMPE for use in total joint replacements. The chemistry, hydrophilicity, and protein adsorption resistance of the coatings were determined, and the wear behavior of the PEG-like coating was examined by two methods: pin-on-disk tribometry to evaluate macroscale behavior, and atomic force microscopy (AFM) to simulate asperity wear. As expected, the coating was found to be highly PEG-like, with approximately 83% ether content by x-ray photoelectron spectroscopy and more hydrophilic and resistant to protein adsorption than uncoated UHMWPE. Pin-on-disk testing showed that the PEG-like coating could survive 3 MPa of contact pressure, comparable to that experienced by total hip replacements. AFM nanoscratching experiments uncovered three damage mechanisms for the coatings: adhesion/microfracture, pure adhesion, and delamination. The latter two mechanisms appear to correlate well with wear patterns induced by pin-on-disk testing and evaluated by attenuated total reflection Fourier transform infrared spectroscopy mapping. Understanding the mechanisms by which the PEG-like coatings wear is critical for improving the behavior of subsequent generations of wear-resistant hydrogel coatings. (c) 2009 Wiley Periodicals, Inc.
Mnatzaganian, George; Ryan, Philip; Reid, Christopher M; Davidson, David C; Hiller, Janet E
2013-09-05
The reported association of smoking with risk of undergoing a total joint replacement (TJR) due to osteoarthritis (OA) is not consistent. We evaluated the independent association between smoking and primary TJR in a large cohort. The electronic records of 54,288 men and women, who were initially recruited for the Second Australian National Blood Pressure study, were linked to the Australian Orthopaedic Association National Joint Replacement Registry to detect total hip replacement (THR) or total knee replacement (TKR) due to osteoarthritis. Competing risk regressions that accounted for the competing risk of death estimated the subhazard ratios for TJR. One-way and probabilistic sensitivity analyses were undertaken to represent uncertainty in the classification of smoking exposure and socioeconomic disadvantage scores. An independent inverse association was found between smoking and risk of THR and TKR observed in both men and women. Compared to non-smokers, male and female smokers were respectively 40% and 30% less likely to undergo a TJR. This significant association persisted after controlling for age, co-morbidities, body mass index (BMI), physical exercise, and socioeconomic disadvantage. The overweight and obese were significantly more likely to undergo TJR compared to those with normal weight. A dose-response relationship between BMI and TJR was observed (P < 0.001). Socioeconomic status was not independently associated with risk of either THR or TKR. The strengths of the inverse association between smoking and TJR, the temporal relationship of the association, together with the consistency in the findings warrant further investigation about the role of smoking in the pathogenesis of osteoarthritis causing TJR.
Hua, Xijin; Li, Junyan; Jin, Zhongmin; Fisher, John
2016-06-01
The occurrence of edge loading in hip joint replacement has been associated with many factors such as prosthetic design, component malposition and activities of daily living. The present study aimed to quantify the occurrence of edge loading/contact at the articulating surface and to evaluate the effect of cup angles and edge loading on the contact mechanics of a modular metal-on-polyethylene (MoP) total hip replacement (THR) during different daily activities. A three-dimensional finite element model was developed based on a modular MoP bearing system. Different cup inclination and anteversion angles were modelled and six daily activities were considered. The results showed that edge loading was predicted during normal walking, ascending and descending stairs activities under steep cup inclination conditions (≥55°) while no edge loading was observed during standing up, sitting down and knee bending activities. The duration of edge loading increased with increased cup inclination angles and was affected by the cup anteversion angles. Edge loading caused elevated contact pressure at the articulating surface and substantially increased equivalent plastic strain of the polyethylene liner. The present study suggested that correct positioning the component to avoid edge loading that may occur during daily activities is important for MoP THR in clinical practice. Copyright © 2016. Published by Elsevier Ltd.
Krishnamoorthy, Vignesh P; Perumal, Rajamani; Daniel, Alfred J; Poonnoose, Pradeep M
2015-12-01
Templating of the acetabular cup size in Total Hip Replacement (THR) is normally done using conventional radiographs. As these are being replaced by digital radiographs, it has become essential to create a technique of templating using digital films. We describe a technique that involves templating the digital films using the universally available acetate templates for THR without the use of special software. Preoperative digital radiographs of the pelvis were taken with a 30 mm diameter spherical metal ball strapped over the greater trochanter. Using standard acetate templates provided by the implant company on magnified digital radiographs, the size of the metal ball (X mm) and acetabular cup (Y mm) were determined. The size of the acetabular cup to be implanted was estimated using the formula 30*Y/X. The estimated size was compared with the actual size of the cup used at surgery. Using this technique, it was possible to accurately predict the acetabular cup size in 28/40 (70%) of the hips. When the accuracy to within one size was considered, templating was correct in 90% (36/40). When assessed by two independent observers, there was good intra-observer and inter-observer reliability with intra-class correlation coefficient values greater than 0.8. It was possible to accurately and reliably predict the size of the acetabular cup, using acetate templates on digital films, without any digital templates.
Cip, Johannes; von Strempel, Archibald; Bach, Christian; Luegmair, Matthias; Benesch, Thomas; Martin, Arno
2014-11-01
Taper junctions of large diameter metal-on-metal femoral heads and femoral stems were described as metal ion generator due to accelerated wear and corrosion. However, literature about the Articular Surface Replacement (ASR) total hip arthroplasty (THA) invariably deals with stems manufactured by DePuy Orthopedics (Warsaw, IN, USA). Nothing is known whether different stems with common 12/14 mm tapers affect failure rate or ion release. 99 ASR THA (88 patients) implanted with CoxaFit or ARGE Geradschaft stems (K-Implant, Hannover, Germany) were retrospectively analyzed. After a mean follow-up of 3.5 years revision rate was 24.5%, mostly due to adverse reaction to metal debris (ARMD). CT scan revealed component loosening in 10.3% and pseudotumoral lesions in 12.6%. Elevated ion concentrations (>7 μg/l) were found in 38.6%. Copyright © 2014 Elsevier Inc. All rights reserved.
Lee, Paul Yuh Feng; Rachala, Madhu; Teoh, Kar Ho; Woodnutt, David John
2016-09-01
Modular cementless elastic acetabular systems have advantages over cemented and hard shell cementless acetabular systems. There are few reports on the medium-term and long-term follow up of this particular type of implant. This study describes our experience with the Atlas IIIp modular acetabular system, which is a thin shell cementless elastic acetabular implant for total hip replacement commercialized under this name in many countries. We prospectively followed 244 patients treated with Atlas IIIp acetabular system between 2001 and 2004. Minimum ten year follow up was available for 148 hips (139 patients) from the original cohort of 263 hips (244 patients). One hundred five patients had died from unrelated causes and were excluded from the results. Post-operative and follow up radiographs of patients were assessed; and Harris hip scores were used as clinical outcome. Revision for any reason was defined as the end point for survivorship analysis. The mean pre-operative Harris hip score was 48 (S.D. 16) and the average post-operative score was 82 (S.D. 12). The mean follow up in our series was 11.5 years, ranging from ten to 13.5 years. Thirteen hips required further surgery in our cohort; of which ten cases required cup revision. The 13-years cumulative implant survival was 91.2 % and the risk of implant revision was 8.8 % at 13 years in 148 hips (139 patients). Kaplan-Meier analysis showed the implant survival rate of 95.2 % at ten years for revision for any reason and 99.4 % for aseptic loosening. Our clinical experience with this acetabular cup suggests good long-term survival rates that are similar to other cups on the market. The clinical experience in this study shows long-term survival rates that are consistent, acceptable and good results achieved with a low revision rate. Therapeutic III; therapeutic study.
Hip arthroscopy using the lateral approach.
Glick, J M
1988-01-01
The benefits of hip arthroscopy are apparent. It produces little postoperative morbidity and can be performed on an outpatient basis. The prompt recovery from the operation is also beneficial, particularly for elderly patients. Distraction of the hip by traction on a fracture table is necessary. Suggested indications for this procedure include synovectomy and synovial biopsy; removal of loose bodies; removal of debris after a closed reduction of a fracture-dislocation; evaluation and treatment of osteochondritis dissecans; evaluation for arthroplasty; and unresolved hip pain. Whether the lateral approach is useful in the following situations is yet to be explored: (1) Evaluation of pediatric conditions such as Legg-Perthes disease and congenital dislocated hip; (2) treatment of localized infection; (3) removal of entrapped methylmethacrylate in total hip replacement; and (4) reducing and fixating an acetabular fracture (M. Brennan, oral communication, April 6, 1987). Arthroscopy of the hip joint by the lateral approach is a valuable addition to the evaluation and treatment of hip disorders.
Eitzen, Ingrid; Fernandes, Linda; Nordsletten, Lars; Risberg, May Arna
2012-12-20
Existent biomechanical studies on hip osteoarthritic gait have primarily focused on the end stage of disease. Consequently, there is no clear consensus on which specific gait parameters are of most relevance for hip osteoarthritis patients with mild to moderate symptoms. The purpose of this study was to explore sagittal plane gait characteristics during the stance phase of gait in hip osteoarthritis patients not eligible for hip replacement surgery. First, compared to healthy controls, and second, when categorized into two subgroups of radiographic severity defined from a minimal joint space of ≤/>2 mm. Sagittal plane kinematics and kinetics of the hip, knee and ankle joint were calculated for total joint excursion throughout the stance phase, as well as from the specific events initial contact, midstance, peak hip extension and toe-off following 3D gait analysis. In addition, the Western Ontario and McMaster Universities Osteoarthritis Index, passive hip range of motion, and isokinetic muscle strength of hip and knee flexion and extension were included as secondary outcomes. Data were checked for normality and differences evaluated with the independent Student's t-test, Welch's t-test and the independent Mann-Whitney U-test. A binary logistic regression model was used in order to control for velocity in key variables. Fourty-eight hip osteoarthritis patients and 22 controls were included in the final material. The patients walked significantly slower than the controls (p=0.002), revealed significantly reduced joint excursions of the hip (p<0.001) and knee (p=0.011), and a reduced hip flexion moment at midstance and peak hip extension (p<0.001). Differences were primarily manifested during the latter 50% of stance, and were persistent when controlling for velocity. Subgroup analyses of patients with minimal joint space ≤/>2 mm suggested that the observed deviations were more pronounced in patients with greater radiographic severity. The biomechanical differences were, however, not reflected in self-reported symptoms or function. Reduced gait velocity, reduced sagittal plane joint excursion, and a reduced hip flexion moment in the late stance phase of gait were found to be evident already in hip osteoarthritis patients with mild to moderate symptoms, not eligible for total hip replacement. Consequently, these variables should be considered as key features in studies regarding hip osteoarthritic gait at all stages of disease. Subgroup analyses of patients with different levels of radiographic OA further generated the hypothesis that the observed characteristics were more pronounced in patients with a minimal joint space ≤2 mm.
Wang, Jie; Tong, Yahui; Jiang, Yingqing; Zhu, Hongxia; Gao, Hui; Wei, Rong; Que, Xianfeng; Gao, Luoluo
2018-05-31
To evaluate the effect of an Internet-based home orthopedic care platform on patients' functional joint recovery, quality of life, and activities of daily living after hip replacement. Most of the functional exercises after arthroplasty are performed outside the hospital. At present, the WeChat platform is used mainly in the inland of China for continuous nursing of patients with chronic disease in the Department of Orthopedics. An experimental design was applied. 400 patients who had undergone hip replacement from April to October 2016 were selected from 18 hospitals with nurse specialists in clinical orthopedics. These patients were randomized into control and intervention groups (n=200 per group).In the control group, only routine nursing care was carried out after discharge. In the intervention group, continuous intervention was performed via the Internet-based orthopedic care platform. The patients in the two groups were compared in terms of functional recovery (Harris hip score), quality of life score (MOS SF-36), and activities of daily living (Barthel index) at 3 and 6 months after discharge. In total, 389 patients were enrolled in this study. There were no significant differences in the baseline data between the two groups. After 6 months of continuous intervention, the mean MOS SF-36 score, Barthel index, and Harris hip score in the intervention group were significantly higher than those in the control group . The study gives full play to the role of clinical nurse specialists, and provides professional home care services to patients in the region after hip replacement through home care orthopedic platform. The platform guides the patients to master the correct disease knowledge and rehabilitation exercise methods, promotes the recovery of joint function, improves the activity of daily living, elevates the quality of life and met the need of long-term management. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Robinson, James C
2011-06-01
To examine the association between hospital market concentration and pricing. Hospitals have been merging into systems that potentially wield bargaining power over private health insurers. Concern is growing among policy makers that these systems may respond to provisions of the 2010 health reform legislation by further increasing consolidation and prices. Multivariate statistical methods were used to evaluate the association between hospital market concentration, prices, and profits (contribution margins) for commercially insured patients admitted for any of 6 major cardiac and orthopedic surgery procedures, adjusting for characteristics of the patient (diagnoses, comorbidities,complications) and of the hospital (size, patient volume, teaching status). Data were obtained on 11,330 patients treated in 61 hospitals in 27 markets across 8 states in 2008. Hospital prices for patients in concentrated markets were higher than hospital prices for otherwise-comparable patients in competitive markets by 25.1% for coronary angioplasty, 13.0%for cardiac rhythm management (CRM) device insertion, 19.2% for total knee replacement, 24.1%for total hip replacement, 19.3% for lumbar spine fusion, and 22.7% for cervical spine fusion (P <.05). Contribution margins were higher in concentrated than in competitive hospital markets by $5259 for angioplasty, $3417 for CRM device insertion, $4123 for total knee replacement, $5889 for total hip replacement, $7931 for lumbar spine fusion, and $4663 for cervical spine fusion (P <.05). Hospitals in concentrated markets charge significantly higher prices and earn significantly higher margins from private insurers than do hospitals in competitive markets.
Incidence and Location of Pain in Young, Active Patients Following Hip Arthroplasty.
Nam, Denis; Nunley, Ryan M; Sauber, Timothy J; Johnson, Staci R; Brooks, Peter J; Barrack, Robert L
2015-11-01
Persistent pain following hip arthroplasty remains a concern, especially in young, active patients. Four hundred twenty patients less than 60 years of age with a pre-symptomatic UCLA score ≥ 6 (196 total hip arthroplasty [THA]; 224 surface replacement arthroplasty [SRA]) completed a pain-drawing questionnaire investigating the location, severity, and frequency of pain around the hip. At a mean of 2.9 years of follow-up, 40% reported pain in at least one location around the hip. There was no difference in the incidence of groin pain between SRA and THA patients (32% vs. 29%, P=0.6), but THA patients had a greater incidence of anterior (25% vs. 8%, P<0.001) and lateral (20% vs. 10%, P=0.01) thigh pain. A high percentage of young, active patients experience persistent pain following hip arthroplasty. Copyright © 2015 Elsevier Inc. All rights reserved.
Return to work and workplace activity limitations following total hip or knee replacement.
Sankar, A; Davis, A M; Palaganas, M P; Beaton, D E; Badley, E M; Gignac, M A
2013-10-01
Total hip (THR) and knee (TKR) replacements increasingly are performed on younger people making return to work a salient outcome. This research evaluates characteristics of individuals with early and later return to work following THR and TKR. Additionally, at work limitations pre-surgery and upon returning to work, and factors associated with work limitations were evaluated. 190 THR and 170 TKR of a total 931 cohort participants were eligible (i.e., working or on short-term disability pre-surgery). They completed questionnaires pre-surgery and 1, 3, 6 and 12 months post-surgery that included demographics, type of occupation, and the Workplace Activity Limitations Scale (WALS). 166 (87%) and 144 (85%) returned to work by 12 months following THR and TKR, respectively. Early (1 month) return to work was associated with, male gender, university education, working in business, finance or administration, and low physical demand work. People with THR returned to work earlier than those with TKR. For both groups, less pain and every day functional limitations were associated with less workplace activity limitations at the time return to work. The majority of individuals working prior to surgery return to work following hip or knee replacement for osteoarthritis (OA) and experience fewer limitations at work than pre-surgery. The changing workforce dynamics and trends toward surgery at younger ages mean that these are important outcomes for clinicians to assess. Additionally, this is important information for employers in understanding continued participation in employment for people with OA. Copyright © 2013 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
HiL simulation in biomechanics: a new approach for testing total joint replacements.
Herrmann, Sven; Kaehler, Michael; Souffrant, Robert; Rachholz, Roman; Zierath, János; Kluess, Daniel; Mittelmeier, Wolfram; Woernle, Christoph; Bader, Rainer
2012-02-01
Instability of artificial joints is still one of the most prevalent reasons for revision surgery caused by various influencing factors. In order to investigate instability mechanisms such as dislocation under reproducible, physiologically realistic boundary conditions, a novel test approach is introduced by means of a hardware-in-the-loop (HiL) simulation involving a highly flexible mechatronic test system. In this work, the underlying concept and implementation of all required units is presented enabling comparable investigations of different total hip and knee replacements, respectively. The HiL joint simulator consists of two units: a physical setup composed of a six-axes industrial robot and a numerical multibody model running in real-time. Within the multibody model, the anatomical environment of the considered joint is represented such that the soft tissue response is accounted for during an instability event. Hence, the robot loads and moves the real implant components according to the information provided by the multibody model while transferring back the position and resisting moment recorded. Functionality of the simulator is proved by testing the underlying control principles, and verified by reproducing the dislocation process of a standard total hip replacement. HiL simulations provide a new biomechanical testing tool for analyzing different joint replacement systems with respect to their instability behavior under realistic movements and physiological load conditions. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
RSA and registries: the quest for phased introduction of new implants.
Nelissen, Rob G H H; Pijls, Bart G; Kärrholm, Johan; Malchau, Henrik; Nieuwenhuijse, Marc J; Valstar, Edward R
2011-12-21
Although the overall survival of knee and hip prostheses at ten years averages 90%, recent problems with several hip and knee prostheses have illustrated that the orthopaedic community, industry, and regulators can still further improve patient safety. Given the early predictive properties of roentgen stereophotogrammetric analysis (RSA) and the meticulous follow-up of national joint registries, these two methods are ideal tools for such a phased clinical introduction. In this paper, we elaborate on the predictive power of RSA within a two-year follow-up after arthroplasty and its relationship to national joint registries. The association between RSA prosthesis-migration data and registry data is evaluated. The five-year rate of revision of RSA-tested total knee replacements was compared with that of non-RSA-tested total knee replacements. Data were extracted from the published results of the national joint registries of Sweden, Australia, and New Zealand. There was a 22% to 35% reduction in the number of revisions of RSA-tested total knee replacements as compared with non-RSA-tested total knee replacements in the national joint registries. Assuming that the total cost of total knee arthroplasty is $37,000 in the United States, a 22% to 35% reduction in the number of revisions (currently close to 55,000 annually) could lead to an estimated annual savings of over $400 million to the health-care system. The phased clinical introduction of new prostheses with two-year RSA results as a qualitative tool could lead to better patient care and could reduce the costs associated with revision total knee arthroplasty. Follow-up in registries is necessary to substantiate these results and to improve post-market surveillance.
NASA Astrophysics Data System (ADS)
Muth, John; Poggie, Matthew; Kulesha, Gene; Michael Meneghini, R.
2013-02-01
Hip and knee replacement can dramatically improve a patient's quality of life through pain relief and restored function. Fixation of hip and knee replacement implants to bone is critical to the success of the procedure. A variety of roughened surfaces and three-dimensional porous surfaces have been used to enhance biological fixation on orthopedic implants. Recently, highly porous metals have emerged as versatile biomaterials that may enhance fixation to bone and are suitable to a number of applications in hip and knee replacement surgery. This article provides an overview of several processes used to create these implant surfaces.
Tribology and total hip joint replacement: current concepts in mechanical simulation.
Affatato, S; Spinelli, M; Zavalloni, M; Mazzega-Fabbro, C; Viceconti, M
2008-12-01
Interest in the rheology and effects of interacting surfaces is as ancient as man. This subject can be represented by a recently coined word: tribology. This term is derived from the Greek word "tribos" and means the "science of rubbing". Friction, lubrication, and wear mechanism in the common English language means the precise field of interest of tribology. Wear of total hip prosthesis is a significant clinical problem that involves, nowadays, a too high a number of patients. In order to acquire further knowledge on the tribological phenomena that involve hip prosthesis wear tests are conducted on employed materials to extend lifetime of orthopaedic implants. The most basic type of test device is the material wear machine, however, a more advanced one may more accurately reproduce some of the in vivo conditions. Typically, these apparatus are called simulators, and, while there is no absolute definition of a joint simulator, its description as a mechanical rig used to test a joint replacement, under conditions approximating those occurring in the human body, is acceptable. Simulator tests, moreover, can be used to conduct accelerated protocols that replicate/simulate particularly extreme conditions, thus establishing the limits of performance for the material. Simulators vary in their level of sophistication and the international literature reveals many interpretations of the design of machines used for joint replacement testing. This paper aims to review the current state of the art of the hip joint simulators worldwide. This is specified through a schematic overview by describing, in particular, constructive solutions adopted to reproduce in vivo conditions. An exhaustive commentary on the evolution and actually existing simulation standards is proposed by the authors. The need of a shared protocol among research laboratories all over the world could lead to a consensus conference.
Partridge, Susan; Tipper, Joanne L; Al-Hajjar, Mazen; Isaac, Graham H; Fisher, John; Williams, Sophie
2018-05-01
Wear and fatigue of polyethylene acetabular cups have been reported to play a role in the failure of total hip replacements. Hip simulator testing under a wide range of clinically relevant loading conditions is important. Edge loading of hip replacements can occur following impingement under extreme activities and can also occur during normal gait, where there is an offset deficiency and/or joint laxity. This study evaluated a hip simulator method that assessed wear and damage in polyethylene acetabular liners that were subjected to edge loading. The liners tested to evaluate the method were a currently manufactured crosslinked polyethylene acetabular liner and an aged conventional polyethylene acetabular liner. The acetabular liners were tested for 5 million standard walking cycles and following this 5 million walking cycles with edge loading. Edge loading conditions represented a separation of the centers of rotation of the femoral head and the acetabular liner during the swing phase, leading to loading of the liner rim on heel strike. Rim damage and cracking was observed in the aged conventional polyethylene liner. Steady-state wear rates assessed gravimetrically were lower under edge loading compared to standard loading. This study supports previous clinical findings that edge loading may cause rim cracking in liners, where component positioning is suboptimal or where material degradation is present. The simulation method developed has the potential to be used in the future to test the effect of aging and different levels of severity of edge loading on a range of cross-linked polyethylene materials. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1456-1462, 2018. © 2017 Wiley Periodicals, Inc.
The incidence of total hip arthroplasty after hip arthroscopy in osteoarthritic patients
2010-01-01
Objective To assess the incidence of total hip arthroplasty (THA) in osteoarthritic patients who were treated by arthroscopic debridement and to evaluate factors that might influence the time interval from the first hip arthroscopy to THA. Design Retrospective clinical series Methods Follow-up data and surgical reports were retrieved from 564 records of osteoarthritic patients that have had hip arthroscopy between the years 2002 to 2009 with a mean follow-up time of 3.2 years (range, 1-6.4 years). The time interval between the first hip arthroscopy to THA was modelled as a function of patient age; level of cartilage damage; procedures performed and repeated arthroscopies with the use of multivariate regression analysis. Results Ninety (16%) of all participants eventually required THA. The awaiting time from the first arthroscopy to a hip replacement was found to be longer in patients younger than 55 years and in a milder osteoarthritic stage. Patients that experienced repeated hip scopes had a longer time to THA than those with only a single procedure. Procedures performed concomitant with debridement and lavage did not affect the time interval to THA. Conclusions In our series of arthroscopic treatment of hip osteoarthritis, 16% required THA over a period of 7 years. Factors that influence the time to arthroplasty were age, degree of osteoarthritis and recurrent procedures. PMID:20670440
Design of a hip prosthetic tribometer based on salat gait cycle
NASA Astrophysics Data System (ADS)
Towijaya, T.; Ismail, R.; Jamari, J.
2017-01-01
Indonesia is the country with the largest muslim population in the world, most of the inhabitants do salat every day. THR (Total Hip Replacement) patients are prohibited from doing salat in normal gait. It leads to the damage of the hip joint prostheses due to impingement and dislocation.This paper reports the design of a pin-on-ring tribometer which is used to measure and analyze the wear volume and the impingement of hip joint prostheses during salat. The modifications of the femoral head and acetabular cup holder are performed to design the reciprocating motion for the movement of the hip prostheses. The interesting finding of the present research is a new mechanism of linked-bar which leads to the feasibility of the measurement of the wear volume and the impingement for THR patients during salat.
Metal-on-metal surface replacement: a triumph of hope over reason: opposes.
Su, Edwin P; Su, Sherwin L
2011-09-09
Hip resurfacing has been performed for over a decade but still raises controversy as an alternative to traditional total hip arthroplasty (THA). Concerns exist about the potential complications of hip resurfacing, including femoral neck fracture and osteonecrosis of the femoral head. Recently, attention has been given to the metal-on-metal bearing of hip resurfacing with regard to production of metal ions, possible tissue necrosis, and rare instances of metal hypersensitivity. Given the success of the gold-standard THA, it is understandable why some surgeons believe metal-on-metal surface replacement to be "a triumph of hope over reason." However, this article opposes that viewpoint, demonstrating that data exist to justify the practice of preserving bone in younger patients. Hip resurfacing can maintain femoral bone without the expense of removing additional acetabular bone by using modern implants with incremental sizing. Furthermore, many of the problems cited with the bearing couple (such as excess metal production) have been due to poor implant designs, which have now been removed from the market. Finally, we now realize that the metal-on-metal articulation is more sensitive to malposition; thus, good surgical technique and experience can solve many of the problems that have been cited in the past. National registry results confirm that in a select population, hip resurfacing performs comparably to THA, while fulfilling the goal of bone preservation. Copyright 2011, SLACK Incorporated.
Rijavec, B; Košak, R; Daniel, M; Kralj-Iglič, V; Dolinar, D
2015-01-01
In order to increase the lifetime of the total hip endoprosthesis, it is necessary to understand mechanisms leading to its failure. In this work, we address volumetric wear of the artificial cup, in particular the effect of its inclination with respect to the vertical. Volumetric wear was calculated by using mathematical models for resultant hip force, contact stress and penetration of the prosthesis head into the cup. Relevance of the dependence of volumetric wear on inclination of the cup (its abduction angle ϑA) was assessed by the results of 95 hips with implanted endoprosthesis. Geometrical parameters obtained from standard antero-posterior radiographs were taken as input data. Volumetric wear decreases with increasing cup abduction angle ϑA. The correlation within the population of 95 hips was statistically significant (P = 0.006). Large cup abduction angle minimises predicted volumetric wear but may increase the risk for dislocation of the artificial head from the cup in the one-legged stance. Cup abduction angle and direction of the resultant hip force may compensate each other to achieve optimal position of the cup with respect to wear and dislocation in the one-legged stance for a particular patient.
Lowe, Catherine J Minns; Davies, Linda; Sackley, Catherine M; Barker, Karen L
2015-09-01
Existing review required updating. To evaluate the effectiveness of physiotherapy exercise after discharge from hospital on function, walking, range of motion, quality of life and muscle strength, for patients following elective primary total hip arthroplasty for osteoarthritis. Systematic review from January 2007 to November 2013. AMED, CINAHL, EMBASE, MEDLINE, Kingsfund Database, and PEDro. Cochrane CENTRAL, BioMed Central (BMC), The Department of Health National Research Register and Clinical Trials.gov register. Searches were overseen by a librarian. Authors were contacted for missing information. No language restrictions were applied. Trials comparing physiotherapy exercise vs usual/standard care, or comparing two types of relevant exercise physiotherapy, following discharge from hospital after elective primary total hip replacement for osteoarthritis were reviewed. Functional activities of daily living, walking, quality of life, muscle strength and joint range of motion. Quality and risk of bias for studies were evaluated. Data were extracted and meta-analyses considered. 11 trials are included in the review. Trial quality was mixed. Newly included studies were assessed as having lower risk of bias than previous studies. Narrative review indicates that physiotherapy exercise after discharge following total hip replacement may potentially benefit patients in terms of function, walking and muscle strengthening. The overall quality and quantity of trials, and their diversity, prevented meta-analyses. Disappointingly, insufficient evidence still prevents the effectiveness of physiotherapy exercise following discharge to be determined for this patient group. High quality, adequately powered, trials with long term follow up are required. Copyright © 2015 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
Avascular necrosis of the femoral head presenting as trochanteric bursitis.
Mandell, B F
1990-01-01
Five patients are described with avascular necrosis of the femoral head who presented with ipsilateral trochanteric bursitis, in the absence of clearcut hip joint disease. Avascular necrosis was indicated by magnetic resonance imaging. It is suggested that clinical trochanteric bursitis, especially when refractory to local corticosteroid treatment, may be the initial sign of hip disease. In the patient with risk factor(s) for avascular necrosis that diagnosis should be considered and evaluated with appropriate studies, such as magnetic resonance imaging, to prevent weight bearing at an early stage and permit possible surgical decompression in the hope of postponing or obviating the need for total hip replacement. PMID:2241294
van Dijk, Joris D; Groothuis-Oudshoorn, Catharina G M; Marshall, Deborah A; IJzerman, Maarten J
2016-06-01
Previous studies have been inconclusive regarding the validity and reliability of preference elicitation methods. The aim of this study was to compare the metrics obtained from a discrete choice experiment (DCE) and profile-case best-worst scaling (BWS) with respect to hip replacement. We surveyed the general US population of men aged 45 to 65 years, and potentially eligible for hip replacement surgery. The survey included sociodemographic questions, eight DCE questions, and twelve BWS questions. Attributes were the probability of a first and second revision, pain relief, ability to participate in sports and perform daily activities, and length of hospital stay. Conditional logit analysis was used to estimate attribute weights, level preferences, and the maximum acceptable risk (MAR) for undergoing revision surgery in six hypothetical treatment scenarios with different attribute levels. A total of 429 (96%) respondents were included. Comparable attribute weights and level preferences were found for both BWS and DCE. Preferences were greatest for hip replacement surgery with high pain relief and the ability to participate in sports and perform daily activities. Although the estimated MARs for revision surgery followed the same trend, the MARs were systematically higher in five of the six scenarios using DCE. This study confirms previous findings that BWS or DCEs are comparable in estimating attribute weights and level preferences. However, the risk tolerance threshold based on the estimation of MAR differs between these methods, possibly leading to inconsistency in comparing treatment scenarios. Copyright © 2016 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Guerra, Mark L; Singh, Parminder J; Taylor, Nicholas F
2015-09-01
To systematically review the effect of early mobilization after hip or knee joint replacement surgery on length of stay in an acute hospital. Randomized controlled trials were selected from electronic databases based on inclusion criterion requiring an experimental group mobilizing (sitting out of bed/walking) earlier than a comparison group post joint replacement surgery of the hip or knee in an acute hospital. Clinically homogeneous data were analyzed with meta-analysis. Five randomized controlled trials (totaling 622 participants) were included for review. A meta-analysis of 5 trials found a reduced length of stay of 1.8 days (95% confidence interval 1.1 to 2.6) in favor of the experimental group. In 4 of the 5 trials the experimental group first sat out of bed within 24 hours post operatively. In 4 of the 5 trials the experimental group first walked within 48 hours post operatively. Individual trials reported benefits in range of motion, muscle strength and health-related quality of life in favor of the experimental group. There were no differences in discharge destinations, incidence of negative outcomes or adverse events attributable to early mobilization when compared to the comparison groups. Early mobilization post hip or knee joint replacement surgery can result in a reduced length of stay of about 1.8 days. Trials that reported these positive results showed that early mobilization can be achieved within 24 hours of operation. This positive gain was achieved without an increase in negative outcomes. © The Author(s) 2014.
Hip Joint Replacement Using Monofilament Polypropylene Surgical Mesh: An Animal Model
Białecki, Jacek; Klimowicz-Bodys, Małgorzata Dorota; Wierzchoś, Edward; Kołomecki, Krzysztof
2014-01-01
Hip joint dysplasia is a deformation of the articular elements (pelvic acetabulum, head of the femur, and/or ligament of the head of the femur) leading to laxity of the hip components and dislocation of the femoral head from the pelvic acetabulum. Diagnosis is based on symptoms observed during clinical and radiological examinations. There are two treatment options: conservative and surgical. The classic surgical procedures are juvenile pubic symphysiodesis (JPS), triple pelvic osteotomy (TPO), total hip replacement (THR), and femoral head and neck resection (FHNE). The aim of this experiment was to present an original technique of filling the acetabulum with a polypropylene implant, resting the femoral neck directly on the mesh. The experiment was performed on eight sheep. The clinical value of the new surgical technique was evaluated using clinical, radiological, and histological methods. This technique helps decrease the loss of limb length by supporting the femoral neck on the mesh equivalent to the femoral head. It also reduces joint pain and leads to the formation of stable and mobile pseudarthrosis. The mesh manifested osteoprotective properties and enabled the formation of a stiff-elastic connection within the hip joint. The method is very cost-effective and the technique itself is simple to perform. PMID:24987672
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hungerford, D.S.; Lennox, D.W.
1985-10-01
Early diagnosis of osteonecrosis by radiograph, bone scan, CT scan, magnetic resonance imaging (MRI), intraosseous pressure measurement, or intraosseous venogram can lead to early successful treatment. For early (Ficat stages I and II) osteonecrosis of the hip, core decompression can provide diagnostic confirmation and pain relief and may prevent progression of disease. For more advanced disease (Ficat stages II and IV), osteotomy, endoprosthetic or bipolar prosthetic replacement, total hip arthroplasty, and arthrodesis are surgical options.86 references.
Ellenrieder, Martin; Bader, Rainer; Bergschmidt, Philipp; Mittelmeier, Wolfram
2016-03-01
Prospectively the outcome after total hip replacement with a new threaded acetabular cup design was compared to an established press-fit cup. After 1, 2 and 5 years, the 36-item Short Form Health Survey, Western Ontario and McMaster University Osteoarthritis Index and Harris Hip Score revealed no significant differences between the two groups (each group: n=42 patients), except for a higher Harris Hip Score in the threaded cup group after five years (p=0.02). After five years, one threaded cup had a mild radiolucent line without further signs of loosening. All other cups of both groups (98.6%) showed a full osseous integration. The cup inclination angle ranged from 41-58° (threaded cups) to 39-77° (press-fit cups). The new threaded cup provides equivalent clinical outcomes and osseous integration but more precise implant positioning compared to the press-fit design. No complications typically ascribed to threaded cups (acetabular fractures, bone resorption, nerve impairment) occurred.
Grivas, Theodoros B; Savvidou, Olga D; Psarakis, Spyridon A; Bernard, Pierre-Francois; Triantafyllopoulos, George; Kovanis, Ioannis; Alexandropoulos, Panagiotis
2007-01-01
Introduction Fractures of the neck of the femoral component have been reported in uncemented total hip replacements, however, to our knowledge, no fractures of the neck of a cementless forged titanium alloy femoral stem coated in the proximal third with hydroxy-apatite have been reported in the medical literature. Case presentation This case report describes a fracture of the neck of a cementless forged titanium alloy stem coated in the proximal third with hydroxy-apatite. Conclusion The neck of the femoral stem failed from fatigue probably because of a combination of factors described analytically below. PMID:18062807
Vassiliou, K; Scholes, S C; Unsworth, A
2007-01-01
Total hip replacements offer relief to a great many patients every year around the world. With an expected service life of around 25 years on most devices, and with younger and younger patients undergoing this surgery, it is of great importance to understand the mechanisms of their function. Tribological testing of both conventional and hard bearing joint combinations have been conducted in many centres throughout the world, and, after being initially abandoned owing to premature failures, hard bearing combinations have been revisited as viable options for joint replacements. Improved design, manufacturing procedures, and material compositions have led to improved performance over first-generation designs in both metal-on-metal and ceramic-on-ceramic hip prostheses. This paper offers a review of the work conducted in an attempt to highlight the most important factors affecting joint performance and tribology of hard bearing combinations. The tribological performance of these joints is superior to that of conventional metal- or ceramic-on-polymer designs.
Hip replacement in femoral head osteonecrosis: current concepts
Scaglione, Michelangelo; Fabbri, Luca; Celli, Fabio; Casella, Francesco; Guido, Giulio
2015-01-01
Summary Osteonecrosis of the femoral head is a destructive disease that usually affects young adults with high functional demands and can have devastating effects on hip joint. The treatment depends on extent and location of the necrosis lesion and on patient’s factors, that suggest disease progression, collapse probability and also implants survival. Non-idiopathic osteonecrosis patients had the worst outcome. There is not a gold standard treatment and frequently it is necessary a multidisciplinary approach. Preservation procedures of the femoral head are the first choice and can be attempted in younger patients without head collapse. Replacement procedure remains the main treatment after failure of preserving procedures and in the late-stage ONFH, involving collapse of the femoral head and degenerative changes to the acetabulum. Resurfacing procedure still has good results but the patient selection is a critical factor. Total hip arthroplasties had historically poor results in patients with osteonecrosis. More recently, reports have shown excellent results, but implant longevity and following revisions are still outstanding problems. PMID:27134633
Ebreo, D; Bell, P J; Arshad, H; Donell, S T; Toms, A; Nolan, J F
2013-08-01
Metal artefact reduction (MAR) MRI is now widely considered to be the standard for imaging metal-on-metal (MoM) hip implants. The Medicines and Healthcare Products Regulatory Agency (MHRA) has recommended cross-sectional imaging for all patients with symptomatic MoM bearings. This paper describes the natural history of MoM disease in a 28 mm MoM total hip replacement (THR) using MAR MRI. Inclusion criteria were patients with MoM THRs who had not been revised and had at least two serial MAR MRI scans. All examinations were reported by an experienced observer and classified as A (normal), B (infection) or C1-C3 (mild, moderate, severe MoM-related abnormalities). Between 2002 and 2011 a total of 239 MRIs were performed on 80 patients (two to four scans per THR); 63 initial MRIs (61%) were normal. On subsequent MRIs, six initially normal scans (9.5%) showed progression to a disease state; 15 (15%) of 103 THRs with sequential scans demonstrated worsening disease on subsequent imaging. Most patients with a MoM THR who do not undergo early revision have normal MRI scans. Late progression (from normal to abnormal, or from mild to more severe MoM disease) is not common and takes place over several years.
Mortality After Total Knee and Total Hip Arthroplasty in a Large Integrated Health Care System.
Inacio, Maria C S; Dillon, Mark T; Miric, Alex; Navarro, Ronald A; Paxton, Elizabeth W
2017-01-01
The number of excess deaths associated with elective total joint arthroplasty in the US is not well understood. To evaluate one-year postoperative mortality among patients with elective primary and revision arthroplasty procedures of the hip and knee. A retrospective analysis was conducted of hip and knee arthroplasties performed in 2010. Procedure type, procedure volume, patient age and sex, and mortality were obtained from an institutional total joint replacement registry. An integrated health care system population was the sampling frame for the study subjects and was the reference group for the study. Standardized 1-year mortality ratios (SMRs) and 95% confidence intervals (CIs) were calculated. A total of 10,163 primary total knee arthroplasties (TKAs), 4963 primary total hip arthroplasties (THAs), 606 revision TKAs, and 496 revision THAs were evaluated. Patients undergoing primary THA (SMR = 0.6, 95% CI = 0.4-0.7) and TKA (SMR = 0.4, 95% CI = 0.3-0.5) had lower odds of mortality than expected. Patients with revision TKA had higher-than-expected mortality odds (SMR = 1.8, 95% CI = 1.1-2.5), whereas patients with revision THA (SMR = 0.9, 95% CI = 0.4-1.5) did not have higher-than-expected odds of mortality. Understanding excess mortality after joint surgery allows clinicians to evaluate current practices and to determine whether certain groups are at higher-than-expected mortality risk after surgery.
Acute hyperkalemia as a complication of intravenous therapy with epsilon-aminocaproic acid.
Banerjee, Arna; Stoica, Cristina; Walia, Ann
2011-11-01
Epsilon-aminocaproic acid (EACA) is used frequently during surgery as prophylaxis to decrease blood loss and transfusion requirements. A rare complication of EACA induced acute hyperkalemia in a patient undergoing total hip replacement is presented. Published by Elsevier Inc.
Taking care of your new hip joint
Hip arthroplasty - precautions; Hip replacement - precautions; Osteoarthritis - hip; Osteoarthritis - knee ... Saunders; 2015:chap 61. Harkess JW, Crockarell JR. Arthroplasty of the hip. In: Azar FM, Beaty JH, ...
Upshur, Ross E G; Moineddin, Rahim; Crighton, Eric J; Mamdani, Muhammad
2006-03-01
The question of how best to reduce waiting times for health care, particularly surgical procedures such as hip and knee replacements is among the most pressing concern of the Canadian health care system. The objective of this study was to test the hypothesis that significant seasonal variation exists in the performance of hip and knee replacement surgery in the province of Ontario. We performed a retrospective, cross-sectional time series analysis examining all hip and knee replacement surgeries in people over the age of 65 in the province of Ontario, Canada between 1992 and 2002. The main outcome measure was monthly hospitalization rates per 100,000 population for all hip and knee replacements. There was a marked increase in the rate of hip and knee replacement surgery over the 10-year period as well as an increasing seasonal variation in surgeries. Highly significant (Fisher Kappa = 16.05, p < 0.01; Bartlett-Kolmogorov-Smirnov Test = 0.31, p < 0.01) and strong (R2Autoreg = 0.85) seasonality was identified in the data. Holidays and utilization caps appear to exert a significant influence on the rate of service provision. It is expected that waiting times for hip and knee replacement could be reduced by reducing seasonal fluctuations in service provision and benchmarking services to peak delivery. The results highlight the importance of system behaviour in seasonal fluctuation of service delivery.
Upshur, Ross EG; Moineddin, Rahim; Crighton, Eric J; Mamdani, Muhammad
2006-01-01
Background The question of how best to reduce waiting times for health care, particularly surgical procedures such as hip and knee replacements is among the most pressing concern of the Canadian health care system. The objective of this study was to test the hypothesis that significant seasonal variation exists in the performance of hip and knee replacement surgery in the province of Ontario. Methods We performed a retrospective, cross-sectional time series analysis examining all hip and knee replacement surgeries in people over the age of 65 in the province of Ontario, Canada between 1992 and 2002. The main outcome measure was monthly hospitalization rates per 100 000 population for all hip and knee replacements. Results There was a marked increase in the rate of hip and knee replacement surgery over the 10-year period as well as an increasing seasonal variation in surgeries. Highly significant (Fisher Kappa = 16.05, p < 0.01; Bartlett-Kolmogorov-Smirnov Test = 0.31, p < 0.01) and strong (R2Autoreg = 0.85) seasonality was identified in the data. Conclusion Holidays and utilization caps appear to exert a significant influence on the rate of service provision. It is expected that waiting times for hip and knee replacement could be reduced by reducing seasonal fluctuations in service provision and benchmarking services to peak delivery. The results highlight the importance of system behaviour in seasonal fluctuation of service delivery. PMID:16509992
Stigmar, Kjerstin; Dahlberg, Leif E; Zhou, Caddie; Jacobson Lidgren, Helena; Petersson, Ingemar F; Englund, Martin
2017-04-01
Background and purpose - Little is know about patterns of sick leave in connection with total hip and knee joint replacement (THR and TKR) in patients with osteoarthritis (OA). Patients and methods - Using registers from southern Sweden, we identified hip and knee OA patients aged 40-59 years who had a THR or TKR in the period 2004-2012. Patients who died or started on disability pension were excluded. We included 1,307 patients with THR (46% women) and 996 patients with TKR (56% women). For the period 1 year before until 2 years after the surgery, we linked individual-level data on sick leave from the Swedish Social Insurance Agency. We created a matched reference cohort from the general population by age, birth year, and area of residence (THR: n = 4,604; TKR: n = 3,425). The mean number of days on sick leave and the proportion (%) on sick leave 12 and 24 months before and after surgery were calculated. Results - The month after surgery, about 90% of patients in both cohorts were on sick leave. At the two-year follow-up, sick leave was lower for both cohorts than 1 year before surgery, except for men with THR, but about 9% of the THR patients and 12-17% of the TKR patients were still sick-listed. In the matched reference cohorts, sick leave was constant at around 4-7% during the entire study period. Interpretation - A long period of sick leave is common after total joint replacement, especially after TKR. There is a need for better knowledge on how workplace adjustments and rehabilitation can facilitate the return to work and can postpone surgery.
So-Osman, Cynthia; Nelissen, Rob G H H; Koopman-van Gemert, Ankie W M M; Kluyver, Ewoud; Pöll, Ruud G; Onstenk, Ron; Van Hilten, Joost A; Jansen-Werkhoven, Thekla M; van den Hout, Wilbert B; Brand, Ronald; Brand, Anneke
2014-04-01
Patient blood management is introduced as a new concept that involves the combined use of transfusion alternatives. In elective adult total hip- or knee-replacement surgery patients, the authors conducted a large randomized study on the integrated use of erythropoietin, cell saver, and/or postoperative drain reinfusion devices (DRAIN) to evaluate allogeneic erythrocyte use, while applying a restrictive transfusion threshold. Patients with a preoperative hemoglobin level greater than 13 g/dl were ineligible for erythropoietin and evaluated for the effect of autologous blood reinfusion. Patients were randomized between autologous reinfusion by cell saver or DRAIN or no blood salvage device. Primary outcomes were mean intra- and postoperative erythrocyte use and proportion of transfused patients (transfusion rate). Secondary outcome was cost-effectiveness. In 1,759 evaluated total hip- and knee-replacement surgery patients, the mean erythrocyte use was 0.19 (SD, 0.9) erythrocyte units/patient in the autologous group (n = 1,061) and 0.22 (0.9) erythrocyte units/patient in the control group (n = 698) (P = 0.64). The transfusion rate was 7.7% in the autologous group compared with 8.3% in the control group (P = 0.19). No difference in erythrocyte use was found between cell saver and DRAIN groups. Costs were increased by €298 per patient (95% CI, 76 to 520). In patients with preoperative hemoglobin levels greater than 13 g/dl, autologous intra- and postoperative blood salvage devices were not effective as transfusion alternatives: use of these devices did not reduce erythrocyte use and increased costs.
Bragdon, Charles R; Malchau, Henrik; Yuan, Xunhua; Perinchief, Rebecca; Kärrholm, Johan; Börlin, Niclas; Estok, Daniel M; Harris, William H
2002-07-01
The purpose of this study was to develop and test a phantom model based on actual total hip replacement (THR) components to simulate the true penetration of the femoral head resulting from polyethylene wear. This model was used to study both the accuracy and the precision of radiostereometric analysis, RSA, in measuring wear. We also used this model to evaluate optimum tantalum bead configuration for this particular cup design when used in a clinical setting. A physical model of a total hip replacement (a phantom) was constructed which could simulate progressive, three-dimensional (3-D) penetration of the femoral head into the polyethylene component of a THR. Using a coordinate measuring machine (CMM) the positioning of the femoral head using the phantom was measured to be accurate to within 7 microm. The accuracy and precision of an RSA analysis system was determined from five repeat examinations of the phantom using various experimental set-ups of the phantom. The accuracy of the radiostereometric analysis, in this optimal experimental set-up studied was 33 microm for the medial direction, 22 microm for the superior direction, 86 microm for the posterior direction and 55 microm for the resultant 3-D vector length. The corresponding precision at the 95% confidence interval of the test results for repositioning the phantom five times, measured 8.4 microm for the medial direction, 5.5 microm for the superior direction, 16.0 microm for the posterior direction, and 13.5 microm for the resultant 3-D vector length. This in vitro model is proposed as a useful tool for developing a standard for the evaluation of radiostereometric and other radiographic methods used to measure in vivo wear.
Wylde, Vikki; Lenguerrand, Erik; Gooberman-Hill, Rachael; Beswick, Andrew D.; Marques, Elsa; Noble, Sian; Horwood, Jeremy; Pyke, Mark; Dieppe, Paul; Blom, Ashley W.
2015-01-01
Abstract Total hip replacement (THR) and total knee replacement (TKR) are usually effective at relieving pain; however, 7% to 23% of patients experience chronic postsurgical pain. These trials aimed to investigate the effect of local anaesthetic wound infiltration on pain severity at 12 months after primary THR or TKR for osteoarthritis. Between November 2009 and February 2012, 322 patients listed for THR and 316 listed for TKR were recruited into a single-centre double-blind randomised controlled trial. Participants were randomly assigned (1:1) to receive local anaesthetic infiltration and standard care or standard care alone. Participants and outcomes assessors were masked to group allocation. The primary outcome was pain severity on the WOMAC Pain Scale at 12 months after surgery. Analyses were conducted using intention-to-treat and per-protocol approaches. In the hip trial, patients in the intervention group had significantly less pain at 12 months postoperative than patients in the standard care group (differences in means: 4.74; 95% confidence interval [CI]: 0.95-8.54; P = 0.015), although the difference was not clinically significant. Post hoc analysis found that patients in the intervention group were more likely to have none to moderate pain than severe pain at 12 months than those in the standard care group (odds ratio: 10.19; 95% CI: 2.10-49.55; P = 0.004). In the knee trial, there was no strong evidence that the intervention influenced pain severity at 12 months postoperative (difference in means: 3.83; 95% CI: −0.83 to 8.49; P = 0.107). In conclusion, routine use of infiltration could be beneficial in improving long-term pain relief for some patients after THR. PMID:25659070
Hereditary hemochromatosis as a risk factor for joint replacement surgery.
Sahinbegovic, Enijad; Dallos, Tomás; Aigner, Elmar; Axmann, Roland; Engelbrecht, Matthias; Schöniger-Hekele, Maximilian; Karonitsch, Thomas; Farkas, Martin; Karger, Thomas; Willeit, Johann; Stölzel, Ulrich; Keysser, Gernot; Datz, Christian; Kiechl, Stefan; Schett, Georg; Zwerina, Jochen
2010-07-01
Hemochromatosis is an inherited disease with iron overload and joint involvement resembling osteoarthritis. To determine the rate of joint replacement surgery in patients with hemochromatosis, we performed a cross-sectional cohort study. A total of 199 individuals with hereditary hemochromatosis were included. The prevalence of joint replacement surgery in hip, knee, and ankle joints because of secondary osteoarthritis was assessed. Data were compared with 917 healthy subjects from the population-based Bruneck study. A total of 32 of 199 individuals with hemochromatosis received joint replacement surgery with a total number of 52 joints replaced. Compared with expected rates in healthy individuals, patients with hemochromatosis had a significantly higher risk for joint replacement surgery (odds ratio 9.0; confidence interval, 4.6-17.4). Joint replacement occurred significantly earlier in life in patients with hemochromatosis; 21.9% of the patients with hemochromatosis and 1.7% of healthy individuals required joint replacement before the age of 50 years (P=.0027). Moreover, patients with hemochromatosis were more likely to require multiple joint replacements (8.5%) than the control group (expected rate 0.3%; P=.0001). Hemochromatosis is a risk factor for joint replacement surgery because of severe secondary osteoarthritis. Copyright 2010 Elsevier Inc. All rights reserved.
Crosnier, Emilie A; Keogh, Patrick S; Miles, Anthony W
2016-08-01
The hip joint is subjected to cyclic loading and motion during activities of daily living and this can induce micromotions at the bone-implant interface of cementless total hip replacements. Initial stability has been identified as a crucial factor to achieve osseointegration and long-term survival. Whilst fixation of femoral stems achieves good clinical results, the fixation of acetabular components remains a challenge. In vitro methods assessing cup stability keep the hip joint in a fixed position, overlooking the effect of hip motion. The effect of hip motion on cup micromotion using a hip motion simulator replicating hip flexion-extension and a six degrees of freedom measurement system was investigated. The results show an increase in cup micromotion under dynamic hip motion compared to Static Flexion. This highlights the need to incorporate hip motion and measure all degrees of freedom when assessing cup micromotion. In addition, comparison of two press-fit acetabular cups with different surface coatings suggested similar stability between the two cups. This new method provides a basis for a more representative protocol for future pre-clinical evaluation of different cup designs. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Wengler, Annelene; Nimptsch, Ulrike; Mansky, Thomas
2014-06-09
The number of hip and knee replacement operations is rising in many industrialized countries. To evaluate the current situation in Germany, we analyzed the frequency of procedures in Germany compared to the USA, with the aid of similar case definitions and taking demographic differences into account. We used individual inpatient data from Germany (DRG statistics) and the USA (Nationwide Inpatient Sample) to study differences in the age- and sex-adjusted rates of hip and knee replacement surgery and the determinants of trends in case numbers over the years 2005 to 2011. In 2011, hip replacement surgery was performed 1.4 times as frequently in Germany as in the USA (284 vs. 204 cases per 100 000 population per year; the American figures have been adjusted to the age and sex structure of the German population). On the other hand, knee replacement surgery was performed 1.5 times as frequently in the USA as in Germany (304 [standardized] vs. 206 cases per 100,000 population per year). Over the period of observation, the rates of both procedures increased in both countries. The number of elective primary hip replacement operations in Germany grew by 11%, from 140,000 to 155 300 (from 170 to 190 per 100,000 persons); after correction for demographic changes, a 3% increase remained. At the same time, the rate of elective primary hip replacement surgery in the USA rose by 28%, from 79 to 96 per 100 000 population, with a 13% increase remaining after correction for demographic changes. There are major differences between Germany and the USA in the frequency of these operations. The observed upward trend in elective primary hip replacement operations was mostly due to demographic changes in Germany; non-demographic factors exerted a stronger influence in the USA than in Germany. With respect to primary knee replacement surgery, non-demographic factors exerted a comparably strong influence in both countries.
Seibert, Rachel; Marcellin-Little, Denis J; Roe, Simon C; DePuy, Venita; Lascelles, B Duncan X
2012-05-01
To determine whether there is a difference between the ability of peak vertical force (PVF), vertical impulse (VI), and percentage body weight distribution (%BW(dist) ) in differentiating which leg is most affected by hip joint pain before total hip replacement (THR) surgery, and for measuring changes in limb use after THR surgery. Prospective clinical study. Dogs (n = 47). Ground reaction force (GRF) data were collected using a pressure-sensitive walkway the day before THR surgery and at ∼3, 6, and 12 months postoperatively. PVF and VI expressed as a percentage of body weight (%PVF, %VI), and %BW(dist) were recorded. Regression models performed separately for each outcome were used for statistical analysis. When comparing limb use between the affected limb (AP) and the nonaffected limb (NP) preoperatively, differences between limbs were statistically significant when evaluated using PVF (P = .023), VI (P = .010), and %BW(dist) (P = .012). When evaluating the magnitude of absolute and percentage change difference in AP limb use preoperatively versus postoperatively, differences were statistically significant when evaluated using PVF (P < .001 and P = .001, respectively), VI (P = .001 and P < .001) and %BW(dist) (P < .001 and P < .001). There appeared to be no difference in the sensitivity of VI, PVF, and %BW(dist) for evaluating limb use before and after THR. © Copyright 2012 by The American College of Veterinary Surgeons.
Ten-Year Outcome of Serum Metal Ion Levels After Primary Total Hip Arthroplasty
Levine, Brett R.; Hsu, Andrew R.; Skipor, Anastasia K.; Hallab, Nadim J.; Paprosky, Wayne G.; Galante, Jorge O.; Jacobs, Joshua J.
2013-01-01
Abstract: We previously reported on the metal ion concentrations of cobalt, chromium, and titanium that were found in the serum of patients three years after they had undergone primary total hip arthroplasty as compared with the concentrations found in the serum of control patients who did not have an implant. This study is a concise update on the serum metal levels found in a cohort of these patients ten years after the time of hip implantation. Of the original seventy-five subjects, metal ion levels were available for forty patients (53%). Ten patients (hybrid group) had received a hybrid total hip replacement that consisted of a modular cobalt-alloy femoral stem with a cobalt-alloy femoral head that had been inserted with cement and a titanium acetabular socket that had been inserted without cement. Nine patients (cobalt-chromium [CoCr] group) had received an implant with an extensively porous-coated modular cobalt-alloy femoral stem and femoral head along with a titanium acetabular socket; the femoral and acetabular components had each been inserted without cement. Eight patients (titanium group) had undergone insertion of a proximally porous-coated modular titanium-alloy femoral stem with a cobalt-alloy femoral head and a titanium acetabular socket; the femoral and acetabular components had each been inserted without cement. Thirteen patients (control group) from the original control group of patients who had not received an implant served as control subjects. Serum metal levels were measured with use of high-resolution sector field inductively coupled plasma mass spectrometry. The hybrid total hip arthroplasty group had mean cobalt levels that were 3.2 times higher at 120 months than they were at baseline, and the cobalt levels in that group were significantly higher than those in the titanium total hip arthroplasty group at thirty-six, sixty, eighty-four, ninety-six, and 120 months (p < 0.01). The hybrid group had mean chromium levels that were 3.9 times higher at 120 months than they were at baseline, and the CoCr total hip arthroplasty group had chromium levels that were 3.6 times higher at 120 months than they were at baseline. The serum titanium levels were higher in the titanium group at all follow-up time intervals as compared with the levels in all other groups, and the level in the titanium group at 120 months was eighteen times higher than it was at baseline (p < 0.01). Patients with well-functioning primary metal-on-polyethylene total hip replacements had elevated serum metal levels for as many as ten years postoperatively. Furthermore, metal release at the modular femoral head-neck junctions, rather than passive dissolution from porous ingrowth surfaces, was likely the dominant source of serum cobalt and chromium. Level of Evidence: Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence. PMID:23515985
Cip, Johannes; Bach, Christian; Widemschek, Mark; Luegmair, Matthias; Martin, Arno
2015-09-01
The articular surface replacement (ASR) total hip arthroplasty (THA) showed accelerated failure rates due to adverse-reaction to metal debris (ARMD). Literature correlating preoperative with intraoperative revision findings respectively post-revision outcome results are rare. 30 of 99 available ASR THA were revised due to ARMD. Mean post-revision follow-up term was 2.3 years. In part, preoperative data did not correlate with intraoperative revision findings. ARMD was even found in asymptomatic patients with non-elevated ion levels. Postoperative pain and metal ions decreased significantly (P ≤ 0.016). Cobalt decreased faster than chrome. Patients with intraoperative pseudotumors, osteolysis or bilateral THA did not have higher pre- or postoperative ion values (P ≥ 0.053). Females showed higher postoperative chrome levels (P=0.031). One major post-revision complication (femoral nerve palsy) and one re-revision (late onset infection) occurred. Copyright © 2015 Elsevier Inc. All rights reserved.
Schoellkopf, William J.; Ballard, David J.; Kaplan, Gary S.; James, Brent; Weinstein, James N.
2017-01-01
Background: To inform consumers and restrain health care cost growth, efforts to promote transparency and to reimburse for care episodes are accelerating in the United States. Objective: To compare characteristics and costs of 30-day episode of care for hip and knee replacement occurring in High Value Healthcare Collaborative (HVHC)-member hospitals to those occurring in like non–HVHC-member hospitals in the same 15 health care markets before interventions by HVHC members to improve health care value for those interventions. Research Design: This is a retrospective analysis of fee-for-service Medicare data from 2012 and 2013. Subjects: For hip arthroplasty, 4030 HVHC-member and 7572 non–HVHC-member, and for knee arthroplasty, 6542 HVHC-member and 13,900 non–HVHC-member fee-for-service Medicare patients aged 65 and older. Measures: Volumes, patient demographics, hospital stay characteristics, and acute and postacute care standardized costs for a 30-day episode of care. Results: HVHC-member hospitals differed from similar non–HVHC-member hospitals in the same health care markets when considering volumes of surgeries, patient demographics, Charlson scores, and patient distance to care during the index admission. There was little variation in acute care costs of hip or knee replacement surgery across health care markets; however, there was substantial variation in postacute care costs across those same markets. We saw less variation in postacute care costs within markets than across markets. Regression analyses showed that HVHC-member status was not associated with shorter lengths of stay, different complication rates, or lower total or postacute care costs for hip or knee replacement. Conclusions: Health care regions appear to be a more important predictor of episode costs of care than HVHC status. PMID:28319584
Feng, Yan; Pistollato, Michele; Charlesworth, Anita; Devlin, Nancy; Propper, Carol; Sussex, Jon
2015-01-01
To assess the association between market concentration of hospitals (as a proxy for competition) and patient-reported health gains after elective primary hip replacement surgery. Patient Reported Outcome Measures data linked to NHS Hospital Episode Statistics in England in 2011/12 were used to analyse the association between market concentration of hospitals measured by the Herfindahl-Hirschman Index (HHI) and health gains for 337 hospitals. The association between market concentration and patient gain in health status measured by the change in Oxford Hip Score (OHS) after primary hip replacement surgery was not statistically significant at the 5% level both for the average patient and for those with more than average severity of hip disease (OHS worse than average). For 12,583 (49.1%) patients with an OHS before hip replacement surgery better than the mean, a one standard deviation increase in the HHI, equivalent to a reduction of about one hospital in the local market, was associated with a 0.104 decrease in patients' self-reported improvement in OHS after surgery, but this was not statistically significant at the 5% level. Hospital market concentration (as a proxy for competition) appears to have no significant influence (at the 5% level) on the outcome of elective primary hip replacement. The generalizability of this finding needs to be investigated. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Hua, Xijin; Li, Junyan; Wang, Ling; Wilcox, Ruth; Fisher, John; Jin, Zhongmin
2015-10-01
One important loosening mechanism of the cemented total hip arthroplasty is the mechanical overload at the bone-cement interface and consequent failure of the cement fixation. Clinical studies have revealed that the outer diameter of the acetabular component is a key factor in influencing aseptic loosening of the hip arthroplasty. The aim of the present study was to investigate the influence of the cup outer diameter on the contact mechanics and cement fixation of a cemented total hip replacement (THR) with different wear penetration depths and under different cup inclination angles using finite element (FE) method. A three-dimensional FE model was developed based on a typical Charnley hip prosthesis. Two acetabular cup designs with outer diameters of 40 and 43 mm were modelled and the effect of cup outer diameter, penetration depth and cup inclination angle on the contact mechanics and cement fixation stresses in the cemented THR were studied. The results showed that for all penetration depths and cup inclination angles considered, the contact mechanics in terms of peak von Mises stress in the acetabular cup and peak contact pressure at the bearing surface for the two cup designs were similar (within 5%). However, the peak von Mises stress, the peak maximum principal stress and peak shear stress in the cement mantle at the bone-cement interface for the 43 mm diameter cup design were predicted to be lower compared to those for the 40 mm diameter cup design. The differences were predicted to be 15-19%, 15-22% and 18-20% respectively for different cup penetration depths and inclination angles, which compares to the clinical difference of aseptic loosening incidence of about 20% between the two cup designs. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Sun, Hong; Fang, Shuying; Yang, Zibo; Zhang, Zhiqi; Kang, Yan; Zhang, Ziji; Liao, Weiming; Fu, Ming; Wu, Peihui
2016-11-08
To investigate the influence of the degree of acetabular deformity and the learning-curve on the acetabular cup positions in total hip arthroplasty (THA) for adults with developmental dysplasia of hip (DDH). Between January 2008 and December 2015, 130 patients (144 hips) with DDH underwent primary THA, and the clinical data were analyzed retrospectively. Fifty-three patients (59 hips) were admitted before 2012, and 77 patients (85 hips) were treated after 2012. There were 32 males and 98 females, aged from 31 to 83 years (mean, 61). Unilateral replacement was performed in 116 cases and bilateral replacement in 14 cases. Of 144 hips, 48 hips were rated as Crowe type I, 57 hips as type II, and 39 hips as type of III/IV. The standard pelvic radiograph was taken within 1 week after operation. The mediCAD software was adopted to measure the angle of anteversion and abduction, bony coverage, and the distance between true rotating center and optimal rotating center to the connection of teardrops and the horizontal distance between two centers to evaluate the qualified rate of acetabular cup positions. Compared with the patients with the same type in 2013-2015 group, the anteversion angle and qualified rate of acetabular cup position significantly decreased in patients with Crowe I ( P <0.05); the horizontal distance significantly increased and qualified rate of acetabular cup position significantly decreased in patients with Crowe II ( P <0.05); and the anteversion angle significantly decreased and the horizontal distance significantly increased in patients with Crowe III/IV ( P <0.05) in 2008-2012 group. But no significant difference was shown in the other indexes ( P >0.05). In all Crowe types, the vertical distance between the true rotating center and the optimal rotating center increased with the degree of acetabular deformity in both 2008-2012 group and 2013-2015 group, showing significant difference ( P <0.05), but no significant difference was found in the other indexes ( P >0.05). For adults with acetabular dysplasia, there are high potential risks for unsatisfactory acetabular cup positions during primary THA. So it is necessary to evaluate acetabular deformities and to sum up operative experience so as to improve the accuracy of cups installation.
Metal-on-Metal Total Hip Arthroplasty: Quality of Online Patient Information.
Crozier-Shaw, Geoff; Queally, Joseph M; Quinlan, John F
2017-03-01
Metal-on-metal total hip arthroplasty (THA) has generated much attention in the media because of early failure of certain implant systems. This study assessed the quality, accuracy, and readability of online information on metal-on-metal THA. The search terms "metal-on-metal hip replacement" and "metal hip replacement" were entered into the 3 most popular search engines. Information quality was assessed with the DISCERN score and a specific metal-on-metal THA content score. Accuracy of information was assessed with a customized score. Readability of the websites was assessed with the Flesch-Kincaid grade level score. A total of 61 unique websites were assessed. For 56% of websites, the target audience was patients. Media or medicolegal sources accounted for 44% of websites. As assessed by DISCERN (range, 16-80) and metal-on-metal THA (range, 0-25) scores, quality of the websites was moderate at best (47.1 and 9.6, respectively). Accuracy (range, 0-8) of the information presented also was moderate, with a mean score of 6.6. Media and medicolegal websites had the lowest scores for both quality and accuracy, despite making up the greatest proportion of sites assessed. Only 1 website (2%) had a Flesch-Kincaid grade level at or less than the recommended level of 8th grade. This study found that online information on metal-on-metal THA was of poor quality, often was inaccurate, and was presented at an inappropriately high reading level, particularly for media and medicolegal websites. Health care providers should counsel patients on the quality of information available and recommend appropriate online resources. [Orthopedics. 2017; 40(2):e262-e268.]. Copyright 2016, SLACK Incorporated.
Postoperative changes in in vivo measured friction in total hip joint prosthesis during walking.
Damm, Philipp; Bender, Alwina; Bergmann, Georg
2015-01-01
Loosening of the artificial cup and inlay is the most common reasons for total hip replacement failures. Polyethylene wear and aseptic loosening are frequent reasons. Furthermore, over the past few decades, the population of patients receiving total hip replacements has become younger and more active. Hence, a higher level of activity may include an increased risk of implant loosening as a result of friction-induced wear. In this study, an instrumented hip implant was used to measure the contact forces and friction moments in vivo during walking. Subsequently, the three-dimensional coefficient of friction in vivo was calculated over the whole gait cycle. Measurements were collected from ten subjects at several time points between three and twelve months postoperative. No significant change in the average resultant contact force was observed between three and twelve months postoperative. In contrast, a significant decrease of up to 47% was observed in the friction moment. The coefficient of friction also decreased over postoperative time on average. These changes may be caused by 'running-in' effects of the gliding components or by the improved lubricating properties of the synovia. Because the walking velocity and contact forces were found to be nearly constant during the observed period, the decrease in friction moment suggests an increase in fluid viscosity. The peak values of the contact force individually varied by 32%-44%. The friction moment individually differed much more, by 110%-129% at three and up to 451% at twelve months postoperative. The maximum coefficient of friction showed the highest individual variability, about 100% at three and up to 914% at twelve months after surgery. These individual variations in the friction parameters were most likely due to different 'running-in' effects that were influenced by the individual activity levels and synovia properties.
Size of metallic and polyethylene debris particles in failed cemented total hip replacements
NASA Technical Reports Server (NTRS)
Lee, J. M.; Salvati, E. A.; Betts, F.; DiCarlo, E. F.; Doty, S. B.; Bullough, P. G.
1992-01-01
Reports of differing failure rates of total hip prostheses made of various metals prompted us to measure the size of metallic and polyethylene particulate debris around failed cemented arthroplasties. We used an isolation method, in which metallic debris was extracted from the tissues, and a non-isolation method of routine preparation for light and electron microscopy. Specimens were taken from 30 cases in which the femoral component was of titanium alloy (10), cobalt-chrome alloy (10), or stainless steel (10). The mean size of metallic particles with the isolation method was 0.8 to 1.0 microns by 1.5 to 1.8 microns. The non-isolation method gave a significantly smaller mean size of 0.3 to 0.4 microns by 0.6 to 0.7 microns. For each technique the particle sizes of the three metals were similar. The mean size of polyethylene particles was 2 to 4 microns by 8 to 13 microns. They were larger in tissue retrieved from failed titanium-alloy implants than from cobalt-chrome and stainless-steel implants. Our results suggest that factors other than the size of the metal particles, such as the constituents of the alloy, and the amount and speed of generation of debris, may be more important in the failure of hip replacements.
Is reverse hybrid hip replacement the solution?
Lindalen, Einar; Havelin, Leif I; Nordsletten, Lars; Dybvik, Eva; Fenstad, Anne M; Hallan, Geir; Furnes, Ove; Høvik, Oystein; Röhrl, Stephan M
2011-12-01
Reverse hybrid hip replacement uses a cemented all-polyethylene cup and an uncemented stem. Despite increasing use of this method in Scandinavia, there has been very little documentation of results. We have therefore analyzed the results from the Norwegian Arthroplasty Register (NAR), with up to 10 years of follow-up. The NAR has been collecting data on total hip replacement (THR) since 1987. Reverse hybrid hip replacements were used mainly from 2000. We extracted data on reverse hybrid THR from this year onward until December 31, 2009, and compared the results with those from cemented implants over the same period. Specific cup/stem combinations involving 100 cases or more were selected. In addition, only combinations that were taken into use in 2005 or earlier were included. 3,963 operations in 3,630 patients were included. We used the Kaplan-Meier method and Cox regression analysis for estimation of prosthesis survival and relative risk of revision. The main endpoint was revision for any cause, but we also performed specific analyses on different reasons for revision. We found equal survival to that from cemented THR at 5 years (cemented: 97.0% (95% CI: 96.8-97.2); reverse hybrid: 96.7% (96.0-97.4)) and at 7 years (cemented: 96.0% (95.7-96.2); reverse hybrid: 95.6% (94.4-96.7)). Adjusted relative risk of revision of the reverse hybrids was 1.1 (0.9-1.4). In patients under 60 years of age, we found similar survival of the 2 groups at 5 and 7 years, with an adjusted relative risk of revision of reverse hybrids of 0.9 (0.6-1.3) compared to cemented implants. With a follow-up of up to 10 years, reverse hybrid THRs performed well, and similarly to all-cemented THRs from the same time period. The reverse hybrid method might therefore be an alternative to all-cemented THR. Longer follow-up time is needed to evaluate whether reverse hybrid hip replacement has any advantages over all-cemented THR.
Pelvic position and movement during hip replacement.
Grammatopoulos, G; Pandit, H G; da Assunção, R; Taylor, A; McLardy-Smith, P; De Smet, K A; Murray, D W; Gill, H S
2014-07-01
The orientation of the acetabular component is influenced not only by the orientation at which the surgeon implants the component, but also the orientation of the pelvis at the time of implantation. Hence, the orientation of the pelvis at set-up and its movement during the operation, are important. During 67 hip replacements, using a validated photogrammetric technique, we measured how three surgeons orientated the patient's pelvis, how much the pelvis moved during surgery, and what effect these had on the final orientation of the acetabular component. Pelvic orientation at set-up, varied widely (mean (± 2, standard deviation (sd))): tilt 8° (2sd ± 32), obliquity -4° (2sd ± 12), rotation -8° (2sd ± 14). Significant differences in pelvic positioning were detected between surgeons (p < 0.001). The mean angular movement of the pelvis between set-up and component implantation was 9° (sd 6). Factors influencing pelvic movement included surgeon, approach (posterior > lateral), procedure (hip resurfacing > total hip replacement) and type of support (p < 0.001). Although, on average, surgeons achieved their desired acetabular component orientation, there was considerable variability (2sd ± 16) in component orientation. We conclude that inconsistency in positioning the patient at set-up and movement of the pelvis during the operation account for much of the variation in acetabular component orientation. Improved methods of positioning and holding the pelvis are required. ©2014 The British Editorial Society of Bone & Joint Surgery.
Physician Reaction to Price Changes: An Episode-of-Care Analysis
Lee, A. James; Mitchell, Janet B.
1994-01-01
Physicians may respond to fee reductions in a variety of ways. This episode-of-care analysis examines the impact of surgical fee reductions (mandated by the Omnibus Budget Reconciliation Acts [OBRAs] of 1986-87) on the overall pattern and cost of health care services provided in association with the surgical procedure itself. The study focuses on six procedure groups: cataract extractions; total hip replacement; total knee replacement; coronary artery bypass graft (CABG) surgery; upper gastrointestinal (GI) endoscopy; and prostatectomy. Only two of these procedures give significant evidence for the existence of a service volume offset to the fee reductions. PMID:10172299
Zhang, Hua; Xu, Zhongwei; Zhou, Aiguo; Yan, Wenlong; Zhao, Pei; Huang, Xiao; Zhang, Jian
2017-01-01
Abstract The aim of this study was to evaluate the efficacy of supplementary fixation in hip arthroplasty with the use of Kirschner-wires and tension band for geriatric patients suffering unstable intertrochanteric osteoporotic fractures. A total of 103 patients aged more than 75 years were recruited. A bipolar or total hip replacement was performed with additional application of Kirschner-wires and tension band, and the participants were followed up for 2 to 11 years. Physical component summary (PCS), mental component summary (MCS), visual analog scale (VAS), and Harris hip score were utilized to evaluate patients’ hip pain and function, as well as the mental condition postoperatively after 1.5 months, 3 months, 6 months, 1 year, and annually thereafter until the latest follow-up in 2015. Patients showed a significant improvement in all scores between 1.5 months and 1 year (P < 0.001), with the good efficacy lasting at least until the 2-year follow-up. None of the patients showed dislocation, implant loosening, or nonunion of the fracture throughout the follow-up period. In conclusion, it was beneficial to treat unstable intertrochanteric osteoporotic fractures in aged patients with hip arthroplasty coupled with Kirschner-wires and tension band. PMID:28072698
Schick, Fabian; Asseln, Malte; Damm, Philipp; Radermacher, Klaus
2018-01-01
Validation of musculoskeletal models for application in preoperative planning is still a challenging task. Ideally, the simulation results of a patient-specific musculoskeletal model are compared to corresponding in vivo measurements. Currently, the only possibility to measure in vivo joint forces is to implant an instrumented prosthesis in patients undergoing a total joint replacement. In this study, a musculoskeletal model of the AnyBody Modeling System was adapted patient-specifically and validated against the in vivo hip joint force measurements of ten subjects performing one-leg stance and level walking. The impact of four model parameters was evaluated; hip joint width, muscle strength, muscle recruitment, and type of muscle model. The smallest difference between simulated and in vivo hip joint force was achieved by using the hip joint width measured in computed tomography images, a muscle strength of 90 N/cm2, a third order polynomial muscle recruitment, and a simple muscle model. This parameter combination reached mean deviations between simulation and in vivo measurement during the peak force phase of 12% ± 14% in magnitude and 11° ± 5° in orientation for one-leg stance and 8% ± 6% in magnitude and 10° ± 5° in orientation for level walking. PMID:29649235
Increased Long-Term Cardiovascular Risk After Total Hip Arthroplasty
Gordon, Max; Rysinska, Agata; Garland, Anne; Rolfson, Ola; Aspberg, Sara; Eisler, Thomas; Garellick, Göran; Stark, André; Hailer, Nils P.; Sköldenberg, Olof
2016-01-01
Abstract Total hip arthroplasty is a common and important treatment for osteoarthritis patients. Long-term cardiovascular effects elicited by osteoarthritis or the implant itself remain unknown. The purpose of the present study was to determine if there is an increased risk of late cardiovascular mortality and morbidity after total hip arthroplasty surgery. A nationwide matched cohort study with data on 91,527 osteoarthritis patients operated on, obtained from the Swedish Hip Arthroplasty Register. A control cohort (n = 270,688) from the general Swedish population was matched 1:3 to each case by sex, age, and residence. Mean follow-up time was 10 years (range, 7–21). The exposure was presence of a hip replacement for more than 5 years. The primary outcome was cardiovascular mortality after 5 years. Secondary outcomes were total mortality and re-admissions due to cardiovascular events. During the first 5 to 9 years, the arthroplasty cohort had a lower cardiovascular mortality risk compared with the control cohort. However, the risk in the arthroplasty cohort increased over time and was higher than in controls after 8.8 years (95% confidence interval [CI] 7.0–10.5). Between 9 and 13 years postoperatively, the hazard ratio was 1.11 (95% CI 1.05–1.17). Arthroplasty patients were also more frequently admitted to hospital for cardiovascular reasons compared with controls, with a rate ratio of 1.08 (95% CI 1.06–1.11). Patients with surgically treated osteoarthritis of the hip have an increased risk of cardiovascular morbidity and mortality many years after the operation when compared with controls. PMID:26871792
Babis, G C; Sakellariou, V I; Chatziantoniou, A N; Soucacos, P N; Megas, P
2011-12-01
We report the results of 62 hips in 62 patients (17 males, 45 females) with mean age of 62.4 years (37 to 81), who underwent revision of the acetabular component of a total hip replacement due to aseptic loosening between May 2003 and November 2007. All hips had a Paprosky type IIIa acetabular defect. Acetabular revision was undertaken using a Procotyl E cementless oblong implant with modular side plates and a hook combined with impaction allografting. At a mean follow-up of 60.5 months (36 to 94) with no patients lost to follow-up and one died due to unrelated illness, the complication rate was 38.7%. Complications included aseptic loosening (19 hips), deep infection (3 hips), broken hook and side plate (one hip) and a femoral nerve palsy (one hip). Further revision of the acetabular component was required in 18 hips (29.0%) and a further four hips (6.4%) are currently loose and awaiting revision. We observed unacceptably high rates of complication and failure in our group of patients and cannot recommend this implant or technique.
[Efficacy analysis on hip replacement for hip-joint diseases with Parkinson disease].
Sun, Qi-Cai; Ru, Xuan-Liang; Xia, Yan-Fei; Liu, Xiao-Li; Song, Bai-Shan; Qiao, Song; Yan, Shi-Gui; Wang, Xiang-Hua
2017-12-25
To explore clinical efficacy of hip replacement for hip-joint diseases with Parkinson disease. From December 2011 to December 2016, 18 patients with hip-joint diseases with Parkinson disease treated by hip replacement, including 8 males and 10 females aged from 59 to 87 years old with an average of 71 years old. Among them, 3 cases were developmental dysplasia of hip, 3 cases were femoral head necrosis and 12 cases were femoral neck fracture. All patients manifested with obvious pain and limitation of stepping ability. Postoperative complications were observed and Harris score were used to compare hip joint function after operation. The incision were healed well, and pain were alleviated or disappeared, and hip joint function were improved. Eighteen patients were followed up from 1 to 3 years with an average of 2.3 years. At the latest follow up, 14 cases recovered freedom-walk, 2 cases could walk with walking stick, 1 case could walk with walking aid and 1 case was died. Among 18 patients, 2 cases were occurred dislocation, and 1 case were died for cardiac disease at 3 months after operation. Four patients were occurred slight pain. There were significant differences in Harris scores among preoperative (41.7±1.4), 6 months after operation(80.1±5.4) and the final follow-up (83.4±2.1), and 10 cases got excellent result, 4 good, 1 fair and 2 poor. Application of hip replacement for hip-joint diseases with Parkinson disease is a safe and effective clinical therapy, and has advantages of less complications and rapid recovery of hip joint function.
Ramamurti, B S; Estok, D M; Jasty, M; Harris, W H
1998-05-01
We developed an analytical technique to determine the paths traced by specific points on the femoral head against the acetabulum in the human hip joint during gait. The purpose of the study was to apply this technique to the mechanical hip simulators chosen to conduct wear tests on polymeric acetabular liners used in total hip replacements. These simulators differ from one another in the type of motion produced, apart from other variables such as type of lubricant and head position. Due to the variation in the kinematics between the machines, the paths traced by the points on the femoral head against the acetabular liner ranged from simple linear traces to figure-8 loops and quasi-elliptical paths during a single simulator cycle. The distances traveled by these points during the same period also varied appreciably among the different hip simulator designs. These results are important when combined with other studies that have shown that kinematics can play an important role in the outcome of in vitro wear experiments. The kinematic differences quantified in this study can partially explain the substantial differences in wear data reported from different simulator designs and also underscore the usefulness of the technique described in this study in judging the results from different hip simulator experiments.
Arbab, Dariusch; van Ochten, Johannes H M; Schnurr, Christoph; Bouillon, Bertil; König, Dietmar
2017-12-01
Patient-reported outcome measures are a critical tool in evaluating the efficacy of orthopedic procedures. The intention of this study was to evaluate reliability, validity, responsiveness and minimally important change of the German version of the Hip dysfunction and osteoarthritis outcome score (HOOS). The German HOOS was investigated in 251 consecutive patients before and 6 months after total hip arthroplasty. All patients completed HOOS, Oxford-Hip Score, Short-Form (SF-36) and numeric scales for pain and disability. Test-retest reliability, internal consistency, floor and ceiling effects, construct validity and minimal important change were analyzed. The German HOOS demonstrated excellent test-retest reliability with intraclass correlation coefficient values > 0.7. Cronbach´s alpha values demonstrated strong internal consistency. As hypothesized, HOOS subscales strongly correlated with corresponding OHS and SF-36 domains. All subscales showed excellent (effect size/standardized response means > 0.8) responsiveness between preoperative assessment and postoperative follow-up. The HOOS and all subdomains showed higher changes than the minimal detectable change which indicates true changes. The German version of the HOOS demonstrated good psychometric properties. It proved to be valid, reliable and responsive to the changes instrument for use in patients with hip osteoarthritis undergoing total hip replacement.
Arabnejad, Sajad; Johnston, Burnett; Tanzer, Michael; Pasini, Damiano
2017-08-01
Current hip replacement femoral implants are made of fully solid materials which all have stiffness considerably higher than that of bone. This mechanical mismatch can cause significant bone resorption secondary to stress shielding, which can lead to serious complications such as peri-prosthetic fracture during or after revision surgery. In this work, a high strength fully porous material with tunable mechanical properties is introduced for use in hip replacement design. The implant macro geometry is based off of a short stem taper-wedge implant compatible with minimally invasive hip replacement surgery. The implant micro-architecture is fine-tuned to locally mimic bone tissue properties which results in minimum bone resorption secondary to stress shielding. We present a systematic approach for the design of a 3D printed fully porous hip implant that encompasses the whole activity spectrum of implant development, from concept generation, multiscale mechanics of porous materials, material architecture tailoring, to additive manufacturing, and performance assessment via in vitro experiments in composite femurs. We show that the fully porous implant with an optimized material micro-structure can reduce the amount of bone loss secondary to stress shielding by 75% compared to a fully solid implant. This result also agrees with those of the in vitro quasi-physiological experimental model and the corresponding finite element model for both the optimized fully porous and fully solid implant. These studies demonstrate the merit and the potential of tuning material architecture to achieve a substantial reduction of bone resorption secondary to stress shielding. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1774-1783, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
An in vitro simulation method for the tribological assessment of complete natural hip joints
Fisher, John; Williams, Sophie
2017-01-01
The use of hip joint simulators to evaluate the tribological performance of total hip replacements is widely reported in the literature, however, in vitro simulation studies investigating the tribology of the natural hip joint are limited with heterogeneous methodologies reported. An in vitro simulation system for the complete natural hip joint, enabling the acetabulum and femoral head to be positioned with different orientations whilst maintaining the correct joint centre of rotation, was successfully developed for this study. The efficacy of the simulation system was assessed by testing complete, matched natural porcine hip joints and porcine hip hemiarthroplasty joints in a pendulum friction simulator. The results showed evidence of biphasic lubrication, with a non-linear increase in friction being observed in both groups. Lower overall mean friction factor values in the complete natural joint group that increased at a lower rate over time, suggest that the exudation of fluid and transition to solid phase lubrication occurred more slowly in the complete natural hip joint compared to the hip hemiarthroplasty joint. It is envisaged that this methodology will be used to investigate morphological risk factors for developing hip osteoarthritis, as well as the effectiveness of early interventional treatments for degenerative hip disease. PMID:28886084
Kasivisvanathan, R; Ramesh, V; Rao Baikady, R; Nadaraja, S
2016-08-01
To estimate the prevalence of preoperative World Health Organization (WHO) defined anaemia in patients presenting for revision hip and knee arthroplasty and its association with transfusion of allogeneic packed red blood cells (PRBC). Studies have mainly investigated the prevalence of preoperative anaemia in primary and not revision hip and knee joint arthroplasty. An analysis of a prospectively collected patient data for 5387 patients having revision hip or knee arthroplasty over a 10-year period at a single high volume centre was conducted. Logistic regression was used to assess whether the presence of WHO defined preoperative anaemia as well as other risk factors were associated with inpatient allogeneic PRBC transfusion. There were 5387 patients assessed of which 3021 (56·01%) patients had revision total hip replacements and 2366 (43·09%) had revision total knee arthroplasty. Of these patients 1956 (36·03%) had preoperative WHO defined anaemia. A total of 2034 (37·08%) patients received at least one unit of allogeneic PRBC during their primary hospital admission. In the final model preoperative WHO defined anaemia was independently associated with allogeneic PRBC transfusion in hip and knee revision surgery OR 4·042 (4·012-4·072 95% CI) CONCLUSIONS: Preoperative anaemia is common in patients presenting for revision hip and knee arthroplasty and independently associated with transfusion of allogeneic PRBC. © 2016 British Blood Transfusion Society.
Computer-Based Training Methods for Surgical Training
2009-10-07
c1J:Ptollmottetv 1an-2cm _,round the J»’l~l.a. Slightly ft ex.the knee " "d lt!move the ooep Ulird of 100 fat Pid. Rtt Pc1lell• Gimbe either everted...pcrtormed to restore norma l fum:tio n o f the musculosk~let£~1 system a lter acute injury ( eg fracture of a bone ). or to treat long standing defom1ities...Enoxaparin in the Prevention of Deep Vein Thrombosis and Symptomatic Pulmonary Embolism After Elective Hip Replacement or Revision Total Hip
Fractures of the greater trochanter following total hip replacement.
Brun, Ole-Christian L; Maansson, Lukas
2013-01-01
We studied the incidence of greater trochanteric fractures at our department following THR. In all we examined 911 patients retrospectively and found the occurance of a greater trochanteric fracture to be 3%. Patients with fractures had significantly poorer outcome on Oxford Hip score, Pain VAS, Satisfaction VAS and EQ-5D compared to THR without fractures. Greater trochanteric fracture following THR is one of the most common complications following THR. It has previously been thought to have little impact on the overall outcome following THR, but our study suggests otherwise.
Pulikottil-Jacob, Ruth; Connock, Martin; Kandala, Ngianga-Bakwin; Mistry, Hema; Grove, Amy; Freeman, Karoline; Costa, Matthew; Sutcliffe, Paul; Clarke, Aileen
2016-01-01
Total hip replacement for end stage arthritis of the hip is currently the most common elective surgical procedure. In 2007 about 7.5% of UK implants were metal-on-metal joint resurfacing (MoM RS) procedures. Due to poor revision performance and concerns about metal debris, the use of RS had declined by 2012 to about a 1% share of UK hip procedures. This study estimated the lifetime cost-effectiveness of metal-on-metal resurfacing (RS) procedures versus commonly employed total hip replacement (THR) methods. We performed a cost-utility analysis using a well-established multi-state semi-Markov model from an NHS and personal and social services perspective. We used individual patient data (IPD) from the National Joint Registry (NJR) for England and Wales on RS and THR surgery for osteoarthritis recorded from April 2003 to December 2012. We used flexible parametric modelling of NJR RS data to guide identification of patient subgroups and RS devices which delivered revision rates within the NICE 5% revision rate benchmark at 10 years. RS procedures overall have an estimated revision rate of 13% at 10 years, compared to <4% for most THR devices. New NICE guidance now recommends a revision rate benchmark of <5% at 10 years. 60% of RS implants in men and 2% in women were predicted to be within the revision benchmark. RS devices satisfying the 5% benchmark were unlikely to be cost-effective compared to THR at a standard UK willingness to pay of £20,000 per quality-adjusted life-year. However, the probability of cost effectiveness was sensitive to small changes in the costs of devices or in quality of life or revision rate estimates. Our results imply that in most cases RS has not been a cost-effective resource and should probably not be adopted by decision makers concerned with the cost effectiveness of hip replacement, or by patients concerned about the likelihood of revision, regardless of patient age or gender.
Forward, John Brent; Greuter, Nancy Elizabeth; Crisall, Santa J; Lester, Houston F
2015-01-01
Postoperative management of pain after total joint arthroplasty remains a challenge despite advancements in analgesics. Evidence shows that complementary modalities with mind-body and tactile-based approaches are valid and effective adjuncts to reduce pain and anxiety postoperatively. To investigate the effectiveness of the "M" Technique (M), a registered method of structured touch using a set sequence and number of strokes, and a consistent level of pressure on hands and feet, compared with guided imagery and usual care, for the reduction of pain and anxiety in patients undergoing elective total knee or hip replacement surgery. Randomized controlled trial: M-TIJRP (MiTechnique and guided Imagery in Joint Replacement Patients [Mighty Junior P]). At a community hospital, 225 male and female patients, aged 38 to 90 years, undergoing elective total hip or knee replacement were randomly assigned to 1 of 3 groups (75 patients in each): M, guided imagery, or usual care. They were blinded to their assignment until the intervention. Reduction of pain and anxiety postoperatively. Secondary outcomes measured use of pain medication and patient satisfaction. This study yielded positive findings for the management of pain and anxiety in patients undergoing elective joint replacement using M and guided imagery for 18 to 20 minutes compared with usual care. M showed the largest predicted decreases in both pain and anxiety between groups. There was no significant difference in narcotic pain medication use between groups. Patient satisfaction survey ratings were highest for M, followed by guided imagery. The benefit of M may be because of the specifically structured sequence of touch by competent caring, trained providers.
Forward, John Brent; Greuter, Nancy Elizabeth; Crisall, Santa J; Lester, Houston F
2015-01-01
Context: Postoperative management of pain after total joint arthroplasty remains a challenge despite advancements in analgesics. Evidence shows that complementary modalities with mind-body and tactile-based approaches are valid and effective adjuncts to reduce pain and anxiety postoperatively. Objective: To investigate the effectiveness of the “M” Technique (M), a registered method of structured touch using a set sequence and number of strokes, and a consistent level of pressure on hands and feet, compared with guided imagery and usual care, for the reduction of pain and anxiety in patients undergoing elective total knee or hip replacement surgery. Methods: Randomized controlled trial: M-TIJRP (MiTechnique and guided Imagery in Joint Replacement Patients [Mighty Junior P]). At a community hospital, 225 male and female patients, aged 38 to 90 years, undergoing elective total hip or knee replacement were randomly assigned to 1 of 3 groups (75 patients in each): M, guided imagery, or usual care. They were blinded to their assignment until the intervention. Main Outcome Measures: Reduction of pain and anxiety postoperatively. Secondary outcomes measured use of pain medication and patient satisfaction. Results: This study yielded positive findings for the management of pain and anxiety in patients undergoing elective joint replacement using M and guided imagery for 18 to 20 minutes compared with usual care. M showed the largest predicted decreases in both pain and anxiety between groups. There was no significant difference in narcotic pain medication use between groups. Patient satisfaction survey ratings were highest for M, followed by guided imagery. Conclusion: The benefit of M may be because of the specifically structured sequence of touch by competent caring, trained providers. PMID:26222093
Bah, Mamadou T; Nair, Prasanth B; Browne, Martin
2009-12-01
Finite element (FE) analysis of the effect of implant positioning on the performance of cementless total hip replacements (THRs) requires the generation of multiple meshes to account for positioning variability. This process can be labour intensive and time consuming as CAD operations are needed each time a specific orientation is to be analysed. In the present work, a mesh morphing technique is developed to automate the model generation process. The volume mesh of a baseline femur with the implant in a nominal position is deformed as the prosthesis location is varied. A virtual deformation field, obtained by solving a linear elasticity problem with appropriate boundary conditions, is applied. The effectiveness of the technique is evaluated using two metrics: the percentages of morphed elements exceeding an aspect ratio of 20 and an angle of 165 degrees between the adjacent edges of each tetrahedron. Results show that for 100 different implant positions, the first and second metrics never exceed 3% and 3.5%, respectively. To further validate the proposed technique, FE contact analyses are conducted using three selected morphed models to predict the strain distribution in the bone and the implant micromotion under joint and muscle loading. The entire bone strain distribution is well captured and both percentages of bone volume with strain exceeding 0.7% and bone average strains are accurately computed. The results generated from the morphed mesh models correlate well with those for models generated from scratch, increasing confidence in the methodology. This morphing technique forms an accurate and efficient basis for FE based implant orientation and stability analysis of cementless hip replacements.
Al Oweidi, Abdelkarim S; Klasen, Joachim; Al-Mustafa, Mahmoud M; Abu-Halaweh, Sami A; Al-Zaben, Khaled R; Massad, Islam M; Qudaisat, Ibrahim Y
2010-06-01
Recent studies suggest that preemptive analgesia may be effective in reducing postoperative pain. One physiologic explanation may be interference with the endogenous opioid response. We investigated whether long-lasting preoperative preemptive analgesia may have an effect on the hormonal stress response after total hip replacement. 42 patients scheduled for elective hip replacement for coxarthrosis were randomized to receive, on the day before the operation, either 5 ml*h(-1) ropivacaine 0.2% (study group, n = 21) or 5 ml*h(-1) saline (control group, n = 21). Postoperative analgesia was achieved in both groups by patient-controlled epidural analgesia (PCEA) with ropivacaine 0.2%. The main outcome measure was the concentration of authentic beta-endorphin [1-31] in plasma up to 4 days after surgery. Additional parameters included concentrations of adrenocorticotrope hormone and cortisol. Both groups were comparable concerning preoperative parameters and pain scores. Epidural blocks were sufficient in all patients for operative analgesia. Preemptive analgesia was performed for 11-20 hours in both groups and led to significantly decreased pain scores before surgery. Preemptive analgesia with epidural ropivacaine did not lead to decreased concentrations of beta-endorphin [1-31] before the start of surgery or in the postoperative period. Furthermore, no differences could be detected in the time course of beta-endorphin and adrenocorticotrope hormone after surgery. However, cortisol concentrations differed significantly between groups before the operation, but showed a comparable rise after surgery. Differences in postoperative pain after preemptive analgesia do not seem to be due to an altered endogenous opioid response.
van Oldenrijk, Jakob; Scholtes, Vanessa A B; van Beers, Loes W A H; Geerdink, Carel H; Niers, Bob B A M; Runne, Wouter; Bhandari, Mohit; Poolman, Rudolf W
2017-01-01
Objectives Primary aim was to compare the functional results at 3 months and 2 years between short and conventional cementless stem total hip arthroplasty (THA). Secondary aim was to determine the feasibility of a double-blind implant-related trial. Design A prospective blinded randomised controlled multicentre trial in patients with osteoarthritis of the hip. All patients, research assistants, clinical assessors, investigators and data analysts were blinded to the type of prosthesis. Population: 150 patients between 18 and 70 years with osteoarthritis of the hip, 75 in the short stem and 75 in the conventional stem group. Mean age: 60 years (SD 7). Interventions: the Collum Femoris Preserving short stem versus the Zweymuller Alloclassic conventional stem. Main outcome measures The Dutch version of the Hip Disability and Osteoarthritis Outcome Score (HOOS). Secondary outcomes measures: Harris Hip Score, the Physical Component Scale of the SF12, the Timed Up and Go test, Pain and the EQ-5D. Feasibility outcomes: continued blinding, protocol adherence and follow-up success rate. Results No significant difference between the two groups. Mean HOOS total score in the short stem group increased 32.7 points from 36.6 (95% CI 32.9 to 40.2) preoperatively to 69.3 (95% CI 66.4 to 72.1) at 3 months follow-up. Mean HOOS total score in the conventional straight stem group increased 36.3 points from 37.1 (95% CI 33.9 to 40.3) preoperatively to 73.4 (95% CI 70.3 to 76.4) at 3 months follow-up. 91.2% of patients remained blinded at 2 years follow-up. Both protocol adherence and follow-up success rate were 98%. Conclusions Functional result at 3 months and 2 years after short stem THA is not superior to conventional cementless THA. There were more perioperative and postoperative complications in the short stem group. Direct comparison of two hip implants in a double-blinded randomised controlled trial is feasible. Trial registration number NTR1560. PMID:29042371
Nesslage, Roman; Radtke, Kerstin; Hohloch, Lisa; Flörkemeier, Thilo; Windhagen, Henning; Lewinski, Gabriela von
2017-04-01
Background Total hip arthroplasty (THA) is very frequently performed. Despite low complication rates, revisions play an important clinical and economical role. The aim of this study was to identify comorbid diseases of patients undergoing primary THA and their potential influence on the survival of hip replacements. Patients/Material and Methods A total of 867 patients were included in this retrospective study. All revisions were reviewed that took place at our hospital within one year of primary implantation of THA. Comorbid diseases were detected by administrative data, using the Elixhauser definition, which includes thirty diseases. The Cox regression model and Fisher's exact test were used to examine correlations between comorbidities and risk of revision. Results 41 Patients required re-operation within the first year of surgery. The presence of one or more of the analysed comorbidities was associated with a greater risk of revision. Deficiency anemia, obesity, drug abuse, alcohol abuse, fluid and electrolyte disorders and peripheral vascular disorders were associated with increased risk of revision (p < 0.05 for all comparisons). The total number of comorbidities and specific comorbid diseases was independently associated with an increased risk of re-operation within the first year of total hip arthroplasty. This information could be helpful in pre- and post-operative risk adjustment and patient selection. Georg Thieme Verlag KG Stuttgart · New York.
21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint (hemi-hip) acetabular metal cemented... (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip) acetabular metal cemented prosthesis is a device intended to be implanted to replace a portion of the hip joint...
Berger, Richard A; Sanders, Sheila A; Thill, Elizabeth S; Sporer, Scott M; Della Valle, Craig
2009-06-01
Advancements in the surgical approach, anesthetic technique, and the initiation of rapid rehabilitation protocols have decreased the duration of hospitalization and subsequent length of recovery following elective total hip arthroplasty. We assessed the feasibility and safety of outpatient total hip arthroplasty in 150 consecutive patients. A comprehensive perioperative anesthesia and rehabilitation protocol including preoperative teaching, regional anesthesia, and preemptive oral analgesia and antiemetic therapy was implemented around a minimally invasive surgical technique. A rapid rehabilitation pathway was started immediately after surgery and patients had the option of being discharged to home the day of surgery if standard discharge criteria were met. All 150 patients were discharged to home the day of surgery, at which time 131 patients were able to walk without assistive devices. Thirty-eight patients required some additional intervention outside the pathway to resolve nausea, hypotension, or sedation prior to discharge. There were no readmissions for pain, nausea, or hypotension yet there was one readmission for fracture and nine emergency room evaluations in the three month perioperative period. This anesthetic and rehabilitation protocol allowed outpatient total hip arthroplasty to be routinely performed in these consecutive patients undergoing primary total hip arthroplasty. With current reimbursement approaches the modest savings to the hospital in length of stay may be outweighed by the additional costs of personnel, thereby making this outpatient system more expensive to implement. Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Older Person's Guide to Joint Replacement
... he or she will refer you to an orthopedic surgeon who does hip and knee replacement surgery. ... The Arthritis Foundation Web The American Academy of Orthopedic Surgeons ' The American Association of Knee and Hip ...
Deciding to have knee or hip replacement
... joint replacement surgery References Harkess JW, Crockarell JR. Arthroplasty of the hip. In: Azar FM, Beaty JH, ... Philadelphia, PA: Elsevier; 2017:chap 3. Mihalko WM. Arthroplasty of the knee. In: Azar FM, Beaty JH, ...
Hip Replacement: MedlinePlus Health Topic
... damage. The most common cause of damage is osteoarthritis . Osteoarthritis causes pain, swelling, and reduced motion in your ... Food and Drug Administration) Genetics Genetics Home Reference: osteoarthritis (National Library of Medicine) Images Hip joint replacement - ...
Preoperative Education for Hip and Knee Replacement: Never Stop Learning.
Edwards, Paul K; Mears, Simon C; Lowry Barnes, C
2017-09-01
Participation in alternative payment models has focused efforts to improve outcomes and patient satisfaction while also lowering cost for elective hip and knee replacement. The purpose of this review is to determine if preoperative education classes for elective hip and knee replacement achieve these goals. Recent literature demonstrates that patients who attend education classes prior to surgery have decreased anxiety, better post-operative pain control, more realistic expectations of surgery, and a better understanding of their surgery. As a result, comprehensive clinical pathways incorporating a preoperative education program for elective hip and knee replacement lead to lower hospital length of stay, higher home discharge, lower readmission, and improved cost. In summary, we report convincing evidence that preoperative education classes are an essential element to successful participation in alternative payment models such as the Bundle Payment Care Initiative.
Femoral neck buttressing: a radiographic and histologic analysis.
Dixon, T; Benjamin, J; Lund, P; Graham, A; Krupinski, E
2000-10-01
To examine the incidence, radiographic and histologic findings of medial femoral neck buttressing in a consecutive group of patients undergoing total hip arthroplasty. Biomechanical parameters were evaluated on standard anteroposterior pelvic radiographs of 113 patients prior to hip replacement surgery. Demographic information on all patients was reviewed and histologic evaluation was performed on specimens obtained at the time of surgery. The incidence of medial femoral neck buttressing was found to be 50% in a consecutive series of patients undergoing total hip arthroplasty. The incidence was slightly higher in women (56% vs. 41%). Patients with buttressing had increased neck-shaft angles and smaller femoral neck diameters than were seen in patients without buttressing. Histologic evaluation demonstrated that the buttress resulted from deposition bone by the periosteum on the femoral neck in the absence of any evidence of femoral neck fracture. It would appear that femoral neck buttressing occurs in response to increased joint reactive forces seen at the hip being transmitted through the femoral neck. The increased joint reactive force can be related to the increased neck shaft angle seen in patients with buttressing.
Grammatopoulos, G; Pandit, H G; da Assunção, R; McLardy-Smith, P; De Smet, K A; Gill, H S; Murray, D W
2014-10-01
There is great variability in acetabular component orientation following hip replacement. The aims of this study were to compare the component orientation at impaction with the orientation measured on post-operative radiographs and identify factors that influence the difference between the two. A total of 67 hip replacements (52 total hip replacements and 15 hip resurfacings) were prospectively studied. Intra-operatively, the orientation of the acetabular component after impaction relative to the operating table was measured using a validated stereo-photogrammetry protocol. Post-operatively, the radiographic orientation was measured; the mean inclination/anteversion was 43° (sd 6°)/ 19° (sd 7°). A simulated radiographic orientation was calculated based on how the orientation would have appeared had an on-table radiograph been taken intra-operatively. The mean difference between radiographic and intra-operative inclination/anteversion was 5° (sd 5°)/ -8° (sd 8°). The mean difference between simulated radiographic and intra-operative inclination/anteversion, which quantifies the effect of the different way acetabular orientation is measured, was 3°/-6° (sd 2°). The mean difference between radiographic and simulated radiographic orientation inclination/anteversion, which is a manifestation of the change in pelvic position between component impaction and radiograph, was 1°/-2° (sd 7°). This study demonstrated that in order to achieve a specific radiographic orientation target, surgeons should implant the acetabular component 5° less inclined and 8° more anteverted than their target. Great variability (2 sd about ± 15°) in the post-operative radiographic cup orientation was seen. The two equally contributing causes for this are variability in the orientation at which the cup is implanted, and the change in pelvic position between impaction and post-operative radiograph. ©2014 The British Editorial Society of Bone & Joint Surgery.
Berger, Ariel; Bozic, Kevin; Stacey, Brett; Edelsberg, John; Sadosky, Alesia; Oster, Gerry
2011-08-01
To examine patterns of pharmacotherapy and health care utilization and costs prior to total knee replacement (TKR) or total hip replacement (THR) in patients with osteoarthritis (OA). Using a large US health insurance claims database, we identified all patients with OA who were ages ≥40 years and had undergone TKR or THR between January 1, 2006 and December 31, 2007. Patients with <2 years of complete data prior to TKR or THR were excluded, as were those with evidence of other conditions for which TKR or THR may be performed (e.g., rheumatoid arthritis). We then examined patterns of health care utilization and costs over the 2-year period preceding surgery. A total of 16,527 patients met all study entry criteria. Their mean ± SD age was 56.6 ± 6.1 years, and 56% of them were women. In the 2 years preceding surgery, 55% of patients received prescription nonsteroidal antiinflammatory drugs, 58% received opioids, and 50% received injections of corticosteroids. The numbers of patients receiving these drugs increased steadily during the presurgery period. The mean ± SD total health care costs in the 2 years preceding surgery were $19,466 ± 29,869, of which outpatient care, inpatient care, and pharmacotherapy represented 45%, 20%, and 20%, respectively. Costs increased from $2,094 in the eighth calendar quarter prior to surgery to $3,100 in the final quarter. Patients with OA who undergo THR or TKR have relatively high levels of use of pain-related pharmacotherapy and high total health care costs in the 2-year period preceding surgery. Levels of utilization and cost increase as the date of surgery approaches. Copyright © 2011 by the American College of Rheumatology.
Surfing for hip replacements: has the "internet tidal wave" led to better quality information.
Nassiri, Mujtaba; Bruce-Brand, Robert A; O'Neill, Francis; Chenouri, Shojaeddin; Curtin, Paul T
2014-07-01
This study aimed to determine the quality of information available on the internet regarding Total Hip Replacement (THR). The unique websites identified were categorised by type and assessed using the DISCERN score, the Journal of the American Medical Association (JAMA) benchmark criteria, and a novel (THR)-specific content score. The presence of the Health On the Net (HON) code, a reported quality assurance marker, was noted. Commercial websites predominate. Governmental & Non-Profit Organizations websites attained the highest DISCERN score. Sites that bore the HONcode seal obtained significantly higher DISCERN and THR content scores than those without the certification. Physicians should recommend the HONcode seal to their patients as a reliable indicator of website quality or, better yet, refer patients to sites they have personally reviewed. Copyright © 2014 Elsevier Inc. All rights reserved.
Restrepo, Camilo; Post, Zachary D; Kai, Brandon; Hozack, William J
2010-03-01
The ceramic-on-ceramic bearing for total hip arthroplasty has an extremely low wear rate and demonstrates minimal inflammatory response in comparison with other bearing choices. However, acoustic emissions such as squeaking and clicking are being reported as annoying complications related to its use. The cause or causes of this phenomenon have not been determined. The purpose of the present study was to evaluate the possibility that design aspects of the femoral component may be a contributing factor to the etiology of squeaking associated with the ceramic-on-ceramic bearing total hip arthroplasty. We retrospectively reviewed 266 consecutive patients (304 hips) who had undergone total hip arthroplasty with use of ceramic-on-ceramic bearings. The first 131 consecutive patients (152 hips) (Group 1) received a hydroxyapatite-coated stem composed of titanium-aluminum-vanadium alloy with a C-taper neck geometry and robust midsection with an anteroposterior diameter of 13 mm. The second 135 consecutive patients (152 hips) (Group 2) also received a hydroxyapatite-coated stem, but in that group the stem was composed of titanium-molybdenum-zirconium-iron alloy, with a V-40 neck geometry and a midsection with an anteroposterior thickness of only 10 mm. All 304 hips received the same cup, composed of titanium-aluminum-vanadium alloy. Demographic characteristics, such as age, sex, height, weight, and body mass index, were similar in both groups. Data regarding the presence of squeaking were obtained prospectively. Patients who were seen for clinical follow-up either expressed the squeaking phenomenon themselves or were asked about it by the physician. Patients who were not seen at a recent clinical follow-up visit were contacted by telephone and were asked specifically about squeaking that might be associated with the hip replacement. Only patients with confirmed squeaking noise were included in the present study. Postoperative radiographs, the Short Form-36 health survey, the Harris hip score, and office or telephone interviews of the patient were used to determine the overall outcome of the procedure. The prevalence of squeaking was seven times higher for patients who received the titanium-molybdenum-zirconium-iron-alloy stem (twenty-seven patients, twenty-eight hips [18.4%]) than in those who received the titanium-aluminum-vanadium-alloy stem (three patients, four hips [2.6%]); this difference was significant (p < 0.0001). Our study suggests that different stem alloys, stem geometries, or neck geometries can have an impact on the frequency of squeaking following a ceramic-on-ceramic total hip arthroplasty.
Vogt, L; Brettmann, K; Pfeifer, K; Banzer, W
2003-04-08
This study examined the angular gait kinematics of the trunk and the pelvis in the frontal plane and their amount of side-to-side asymmetry in patients after total hip replacement arthroplasty. The angular gait kinematics of 12 male hip arthroplasty patients (53-70 years) were compared to ten age-matched and ten young (24-35 years) male control subjects. Average step times and medio-lateral oscillation amplitudes of the pelvic and thoracic recordings were calculated for each step. Between successive steps the asymmetry ratio was computed and the mean angle around which the side-to-side oscillations occurred was compared to the angle in a symmetrical standing trial. ANOVA indicated no significant side differences in relative step cycle durations. Patients and senior controls had significantly (p<0.01) less pelvis side-to-side displacements than the younger controls. No significant between-group differences could be detected for the average asymmetry ratio. However, during walking the patients showed a significantly (p<0.01) increased lateral thorax and pelvis deviation. Hip replacement patients' thoracic and pelvic position is characterized by a lateral shift throughout the gait cycle, while left and right symmetry of angular movements amplitudes remain at about the same value of unimpaired subjects.
García-Rey, Eduardo
2017-05-12
Even with good surgical preparation, adequate primary stability of the acetabular component is not always achieved after primary total hip replacement (THR). We hypothesise that adequate bone preparation for appropriate cortical loading would allow us to avoid screw use. A total of 791 uncemented cups were analysed to compare the need for screws to obtain primary fixation in 5 different designs. Arthritic hips with inflammatory arthritis or severe congenital hip disease were excluded. A press-fit technique was first tried in all hips and screws were only used when strictly needed. Radiological acetabular shape and postoperative cup position were assessed in all hips. The mean follow-up was 9.6 (5-15) years. Screws were required in 155 hips (19.6%). We could not detect any difference in the percentage of screw use between designs. We found that female patients (odds ratio [OR] 2.06; 95% confidence interval [CI], 1.41-3.02) and cups with a greater distance to the hip rotation centre on the postoperative radiograph (OR 1.69; 95% CI, 1.17-2.45) had a higher risk for screw use. A greater anteversion of the cup had a lower risk for screw use (OR 0.96; 95% CI, 0.94-0.99). At latest follow-up no hips had needed revision for aseptic loosening. Good intraoperative technique is not enough to avoid screw use since more accurate cup position and reconstruction of the hip rotation centre are required for an adequate interference fit. A press-fit technique can provide similar mid-term results to screw use in hips without severe deformities.
Cost-effectiveness of enhanced recovery in hip and knee replacement: a systematic review protocol.
Murphy, Jacqueline; Pritchard, Mark G; Cheng, Lok Yin; Janarthanan, Roshni; Leal, José
2018-03-14
Hip and knee replacement represents a significant burden to the UK healthcare system. 'Enhanced recovery' pathways have been introduced in the National Health Service (NHS) for patients undergoing hip and knee replacement, with the aim of improving outcomes and timely recovery after surgery. To support policymaking, there is a need to evaluate the cost-effectiveness of enhanced recovery pathways across jurisdictions. Our aim is to systematically summarise the published cost-effectiveness evidence on enhanced recovery in hip and knee replacement, both as a whole and for each of the various components of enhanced recovery pathways. A systematic review will be conducted using MEDLINE, EMBASE, Econlit and the National Health Service Economic Evaluations Database. Separate search strategies were developed for each database including terms relating to hip and knee replacement/arthroplasty, economic evaluations, decision modelling and quality of life measures.We will extract peer-reviewed studies published between 2000 and 2017 reporting economic evaluations of preoperative, perioperative or postoperative enhanced recovery interventions within hip or knee replacement. Economic evaluations alongside cohort studies or based on decision models will be included. Only studies with patients undergoing elective replacement surgery of the hip or knee will be included. Data will be extracted using a predefined pro forma following best practice guidelines for economic evaluation, decision modelling and model validation.Our primary outcome will be the cost-effectiveness of enhanced recovery (entire pathway and individual components) in terms of incremental cost per quality-adjusted life year. A narrative synthesis of all studies will be presented, focussing on cost-effectiveness results, study design, quality and validation status. This systematic review is exempted from ethics approval because the work is carried out on published documents. The results of the review will be disseminated in a peer-reviewed academic journal and at conferences. CRD42017059473. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Cost-effectiveness of enhanced recovery in hip and knee replacement: a systematic review protocol
Pritchard, Mark G; Cheng, Lok Yin; Janarthanan, Roshni
2018-01-01
Introduction Hip and knee replacement represents a significant burden to the UK healthcare system. ‘Enhanced recovery’ pathways have been introduced in the National Health Service (NHS) for patients undergoing hip and knee replacement, with the aim of improving outcomes and timely recovery after surgery. To support policymaking, there is a need to evaluate the cost-effectiveness of enhanced recovery pathways across jurisdictions. Our aim is to systematically summarise the published cost-effectiveness evidence on enhanced recovery in hip and knee replacement, both as a whole and for each of the various components of enhanced recovery pathways. Methods and analysis A systematic review will be conducted using MEDLINE, EMBASE, Econlit and the National Health Service Economic Evaluations Database. Separate search strategies were developed for each database including terms relating to hip and knee replacement/arthroplasty, economic evaluations, decision modelling and quality of life measures. We will extract peer-reviewed studies published between 2000 and 2017 reporting economic evaluations of preoperative, perioperative or postoperative enhanced recovery interventions within hip or knee replacement. Economic evaluations alongside cohort studies or based on decision models will be included. Only studies with patients undergoing elective replacement surgery of the hip or knee will be included. Data will be extracted using a predefined pro forma following best practice guidelines for economic evaluation, decision modelling and model validation. Our primary outcome will be the cost-effectiveness of enhanced recovery (entire pathway and individual components) in terms of incremental cost per quality-adjusted life year. A narrative synthesis of all studies will be presented, focussing on cost-effectiveness results, study design, quality and validation status. Ethics and dissemination This systematic review is exempted from ethics approval because the work is carried out on published documents. The results of the review will be disseminated in a peer-reviewed academic journal and at conferences. PROSPERO registration number CRD42017059473. PMID:29540418
Functional activity in patients after total hip replacement.
Pogorzała, Adam M; Stryła, Wanda; Nowakowski, Andrzej
2012-11-08
Osteoarthritis of hip joints is one of the most common diseases limiting social functioning of patients. Pain and mobility disorders are major problems associated with the disease. The goal of the study was to compare the efficacy of surgical treatment in a selected group of patients using a modified Harris Hip Score questionnaire including questions regarding the pain, the type of gait disorders and the functional activity. Surgical treatment helped to reduce the pain and improve the gait quality and parameters as well as functional activities associated with putting on socks and shoes, climbing stairs, sitting and using public transportation. Following conclusions were drawn after the study: Surgical treatment leads to significant reduction in hip pain. Mobility improvement was observed in most analyzed patients in early post-operative period as a consequence of hip contracture and pain being eliminated. The walking speed and distance improved significantly during the first 3 months after the surgery. All patients were satisfied with the treatment.
Groin pain and iliopsoas bursitis: always a cause-effect relationship?
Di Sante, Luca; Paoloni, Marco; De Benedittis, Stefano; Tognolo, Lucrezia; Santilli, Valter
2014-01-01
Iliopsoas bursitis (IB) is characterized by inflammation and enlargement of the iliopsoas bursa. Although this condition is often associated with degenerative or inflammatory arthritis, infections, trauma, overuse and impingement syndromes, osteonecrosis and hip replacement, the pathogenesis of IB remains uncertain. We present a case report of IB associated with moderate hip osteoarthritis (HOA). We present a case report of a 73-year-old man with chronic left hip pain that did not respond to conservative treatments. An ultrasonography examination of the left hip revealed fluid-induced distension of the iliopsoas bursa, which was treated with aspiration followed by a corticosteroid-anesthetic injection. At the 30-day follow-up, despite an initial improvement in the patient's symptoms, both the pain and functional limitation returned, though not in association with bursa distension. The patient therefore underwent a total hip arthroplasty, which fully relieved the symptoms. We hypothesize that iliopsoas bursitis may, when associated with other pathological conditions, not be the only source of pain. It should, nevertheless, be considered for differential diagnosis purposes.
Do financial incentives trump clinical guidance? Hip Replacement in England and Scotland.
Papanicolas, Irene; McGuire, Alistair
2015-12-01
Following devolution in 1999 England and Scotland's National Health Services diverged, resulting in major differences in hospital payment. England introduced a case payment mechanism from 2003/4, while Scotland continued to pay through global budgets. We investigate the impact this change had on activity for Hip Replacement. We examine the financial reimbursement attached to uncemented Hip Replacement in England, which has been more generous than for its cemented counterpart, although clinical guidance from the National Institute for Clinical Excellence recommends the later. In Scotland this financial differential does not exist. We use a difference-in-difference estimator, using Scotland as a control, to test whether the change in reimbursement across the two countries had an influence on treatment. Our results indicate that financial incentives are directly linked to the faster uptake of the more expensive, uncemented Hip Replacement in England, which ran against the clinical guidance. Copyright © 2015 Elsevier B.V. All rights reserved.
Taljanovic, Mihra S; Graham, Anna R; Benjamin, James B; Gmitro, Arthur F; Krupinski, Elizabeth A; Schwartz, Stephanie A; Hunter, Tim B; Resnick, Donald L
2008-05-01
To correlate the amount of bone marrow edema (BME) calculated by magnetic resonance imaging(MRI) with clinical findings, histopathology, and radiographic findings, in patients with advanced hip osteoarthritis(OA). The study was approved by The Institutional Human Subject Protection Committee. Coronal MRI of hips was acquired in 19 patients who underwent hip replacement. A spin echo (SE) sequence with four echoes and separate fast spin echo (FSE) proton density (PD)-weighted SE sequences of fat (F) and water (W) were acquired with water and fat suppression, respectively. T2 and water:fat ratio calculations were made for the outlined regions of interest. The calculated MRI values were correlated with the clinical, radiographic, and histopathologic findings. Analyses of variance were done on the MRI data for W/(W + F) and for T2 values (total and focal values) for the symptomatic and contralateral hips. The values were significantly higher in the study group. Statistically significant correlations were found between pain and total W/(W + F), pain and focal T2 values, and the number of microfractures and calculated BME for the focal W/(W + F) in the proximal femora. Statistically significant correlations were found between the radiographic findings and MRI values for total W/(W + F), focal W/(W + F) and focal T2 and among the radiographic findings, pain, and hip movement. On histopathology, only a small amount of BME was seen in eight proximal femora. The amount of BME in the OA hip, as measured by MRI, correlates with the severity of pain, radiographic findings, and number of microfractures.
Revision Hip Arthroscopy Indications and Outcomes: A Systematic Review.
Sardana, Vandit; Philippon, Marc J; de Sa, Darren; Bedi, Asheesh; Ye, Lily; Simunovic, Nicole; Ayeni, Olufemi R
2015-10-01
To identify the indications and outcomes in patients undergoing revision hip arthroscopy. The electronic databases Embase, Medline, HealthStar, and PubMed were searched from 1946 to July 19, 2014. Two blinded reviewers searched, screened, and evaluated the data quality of the studies using the Methodological Index for Non-Randomized Studies scale. Data were abstracted in duplicate. Agreement and descriptive statistics are presented. Six studies were included (3 prospective case series and 3 retrospective chart reviews), with a total of 448 hips examined. The most common indications for revision hip arthroscopy included residual femoroacetabular impingement (FAI), labral tears, and chondral lesions. The mean interval between revision arthroscopy and the index procedure was 25.6 months. Overall, the modified Harris Hip Score improved by a mean of 33.6% (19.3 points) from the baseline score at 1-year follow-up. In 14.6% of patients, further surgical procedures were required, including re-revision hip arthroscopy (8.0%), total hip replacement (5.6%), and hip resurfacing (1.0%). Female patients more commonly underwent revision hip arthroscopy (59.7%). The current evidence examined in this review supports revision hip arthroscopy as a successful intervention to improve functional outcomes (modified Harris Hip Score) and relieve pain in patients with residual symptoms after primary FAI surgery, although the outcomes are inferior when compared with a matched cohort of patients undergoing primary hip arthroscopy for FAI. The main indication for revision is a candidate who has symptoms due to residual cam- or pincer-type deformity that was either unaddressed or under-resected during the index operation. However, it is important to consider that the studies included in this review are of low-quality evidence. Surgeons should consider incorporating a minimum 2-year follow-up for individuals after index hip-preservation surgery because revisions tended to occur within this time frame. Level IV, systematic review of Level III and IV studies. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Vanhegan, I S; Malik, A K; Jayakumar, P; Ul Islam, S; Haddad, F S
2012-05-01
Revision arthroplasty of the hip is expensive owing to the increased cost of pre-operative investigations, surgical implants and instrumentation, protracted hospital stay and drugs. We compared the costs of performing this surgery for aseptic loosening, dislocation, deep infection and peri-prosthetic fracture. Clinical, demographic and economic data were obtained for 305 consecutive revision total hip replacements in 286 patients performed at a tertiary referral centre between 1999 and 2008. The mean total costs for revision surgery in aseptic cases (n = 194) were £11 897 (sd 4629), for septic revision (n = 76) £21 937 (sd 10 965), for peri-prosthetic fracture (n = 24) £18 185 (sd 9124), and for dislocation (n = 11) £10 893 (sd 5476). Surgery for deep infection and peri-prosthetic fracture was associated with longer operating times, increased blood loss and an increase in complications compared to revisions for aseptic loosening. Total inpatient stay was also significantly longer on average (p < 0.001). Financial costs vary significantly by indication, which is not reflected in current National Health Service tariffs.
Xu, Jiawei; Xu, Chen; Mao, Yuanqing; Zhang, Jincheng; Li, Huiwu; Zhu, Zhenan
2016-06-01
We sought to evaluate posterosuperior placement of the acetabular component at the true acetabulum during acetabular reconstruction in patients with Crowe type-IV developmental dysplasia of the hip. Using pelvic computed tomography and image processing, we developed a two-dimensional mapping technique to demonstrate the distribution of preoperative three-dimensional cup coverage at the true acetabulum, determined the postoperative location of the acetabular cup, and calculated postoperative three-dimensional coverage for 16 Crowe type-IV dysplastic hips in 14 patients with a mean age of 52 years (33-78 years) who underwent total hip arthroplasty. Mean follow-up was 6.3 years (5.5-7.3 years). On preoperative mapping, the maximum three-dimensional coverage using a 44-mm cup was 87.31% (77.36%-98.14%). Mapping enabled the successful replacement of 16 hips using a mean cup size of 44.13 mm (42-46 mm) with posterosuperior placement of the cup. Early weight-bearing and no prosthesis revision or loosening during follow-up were achieved in all patients. The postoperative two-dimensional coverage on anteroposterior radiographs and three-dimensional coverage were 96.15% (89.49%-100%) and 83.42% (71.81%-98.50%), respectively. This technique may improve long-term implant survival in patients with Crowe-IV developmental dysplasia of the hip undergoing total hip arthroplasty by allowing the use of durable bearings, increasing host bone coverage, ensuring initial stability, and restoring the normal hip center. Copyright © 2015 Elsevier Inc. All rights reserved.
Zhe Cao; Shaojie Su; Hao Tang; Yixin Zhou; Zhihua Wang; Hong Chen
2017-07-01
With the aging of population, the number of Total Hip Replacement Surgeries (THR) increased year by year. In THR, inaccurate position of the implanted prosthesis may lead to the failure of the operation. In order to reduce the failure rate and acquire the real-time pose of Anterior Pelvic Plane (APP), we propose a measurement system in this paper. The measurement system includes two parts: Initial Pose Measurement Instrument (IPMI) and Real-time Pose Measurement Instrument (RPMI). IPMI is used to acquire the initial pose of the APP, and RPMI is used to estimate the real-time pose of the APP. Both are composed of an Inertial Measurement Unit (IMU) and magnetometer sensors. To estimate the attitude of the measurement system, the Extended Kalman Filter (EKF) is adopted in this paper. The real-time pose of the APP could be acquired together with the algorithm designed in the paper. The experiment results show that the Root Mean Square Error (RMSE) is within 1.6 degrees, which meets the requirement of THR operations.
Sandri, Andrea; Sambugaro, Elena
2013-01-01
The incidence and severity of heterotopic ossification (HO) in two homogeneous groups of patients that received surface replacement arthroplasty (SRA) and conventional total hip arthroplasty (THA) were evaluated retrospectively. Thirty-nine patients undergoing 42 hip resurfacing procedures and 41 primary cementless THAs through an anterolateral approach received a 10-day course of 150 mg/die of indomethacin postoperatively. The median surgical time was 190 minutes and 156 minutes, respectively (P < 0.003). At a minimum 1-year followup, the development of HO was assessed on standard X-ray using Brooker grading. Ectopic bone formation was detected in five cases (11.9%, two Brooker grade I and three grade II) in the SRA group and in 14 hips (34.1%, 12 grade I and two grade II) treated with conventional THA, but the difference was not significant (P < 0.11). No clinically relevant periprosthetic ossification (Brooker III or IV) occurred in both groups. Although the difference was not statistically significant, the incidence of HO after SRA was lower than conventional THA. More extensive soft tissue trauma, bone debris, and longer operative time in hip resurfacing are not likely to be absolute risk factors for HO. Further investigations including larger patient populations are needed to confirm these findings. PMID:23865045
Surface replacement conversion: results depend upon reason for revision.
Su, E P; Su, S L
2013-11-01
Surface hip replacement (SHR) is generally used in younger, active patients as an alternative conventional total hip replacement in part because of the ability to preserve femoral bone. This major benefit of surface replacement will only hold true if revision procedures of SHRs are found to provide good clinical results. A retrospective review of SHR revisions between 2007 and 2012 was presented, and the type of revision and aetiologies were recorded. There were 55 SHR revisions, of which 27 were in women. At a mean follow-up of 2.3 years (0.72 to 6.4), the mean post-operative Harris hip score (HHS) was 94.8 (66 to 100). Overall 23 were revised for mechanical reasons, nine for impingement, 13 for metallosis, nine for unexplained pain and one for sepsis. Of the type of revision surgery performed, 14 were femoral-only revisions; four were acetabular-only revisions, and 37 were complete revisions. We did not find that clinical scores were significantly different between gender or different types of revisions. However, the mean post-operative HHS was significantly lower in patients revised for unexplained pain compared with patients revised for mechanical reasons (86.9 (66 to 100) versus 99 (96 to 100); p = 0.029). There were two re-revisions for infection in the entire cohort. Based on the overall clinical results, we believe that revision of SHR can have good or excellent results and warrants a continued use of the procedure in selected patients. Close monitoring of these patients facilitates early intervention, as we believe that tissue damage may be related to the duration of an ongoing problem. There should be a low threshold to revise a surface replacement if there is component malposition, rising metal ion levels, or evidence of soft-tissue abnormalities.
Huang, Phil; Lyons, Matt; O'Sullivan, Michael
2018-02-01
Despite the well-documented decline in the use of metal-on-metal (MoM) implants over the last decade, there are still controversies regarding whether all MoM implants are created equally. Complications such as elevated serum metal ion levels, aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL) and pseudotumours have all been well documented, but recent studies suggest increased risk of infection with MoM bearing surfaces. Most of these studies however have small patient numbers. The purpose of this study was to examine the cumulative incidence of revision for infection of MoM bearing surfaces in primary hip arthroplasty at a national and single-surgeon level. Data was collected from the Australian Orthopaedic Association National Joint Replacement Registry, which contains over 98% of all arthroplasties performed in Australia since 2001. The cumulative incidence of revision for infection was extracted at a national level and single-surgeon level. Two hundred seventy-six thousand eight hundred seventy-eight subjects were documented in the Australian registry. The 10-year cumulative percent revision for infection of MoM bearing surfaces in primary total hip replacement (THR) was 2.5% at a national level, compared to 0.8% for other bearing surfaces. The senior author contributed 1755 subjects with 7-year follow-up and a cumulative percent revision for infection of MoM bearing surfaces in primary THR of 36.9%, compared to 2.0% for other bearing surfaces. The cumulative percent of revision of MoM bearing surfaces is higher compared to other bearing surfaces; this is especially pronounced in cumulative percent of revision for infection. There was a higher cumulative percent of revision for infection in MoM bearings surfaces (in particular, large-head MoM) compared to other bearing surfaces at both the national and individual-surgeon level.
Silver, A; Eichorn, A; Kral, J; Pickett, G; Barie, P; Pryor, V; Dearie, M B
1996-06-01
Twenty-five percent of all nosocomial infections are wound infections. Professional guidelines support the timely use of preoperative prophylaxis for prevention of postoperative wound infections. Barriers exist in implementing this practice. IPRO, the New York State peer review organization, as part of the Health Care Financing Administration's Health Care Quality Improvement Program, sought to determine the proportion of patients receiving timely antibiotic prophylaxis for aortic grafts, hip replacements and colon resections in 44 hospitals in New York State. IPRO conducted a retrospective medical record review of 44 hospitals through out New York State stratified for teaching, nonteaching status. A sample was drawn of 2651 patients, 2256 from Medicare and 395 from Medicaid, undergoing either abdominal aortic aneurysm repair, partial or total hip replacement or large bowel resection. The study determined the proportion of patients who had documentation of receiving antibiotics and those who received antibiotics timely, that is less than or equal to 2 hours preoperatively. Eighty-six percent of patients had documentation of receiving an antibiotic. Forty-six percent of aneurysm repairs and 60% of hip replacements had evidence of receiving timely antibiotic prophylaxis, that is within 2 hours prior to surgery. For colon resections, 73% of cases had either oral prophylaxis or timely parenteral therapy. An increased proportion of patients had received parenteral antibiotics prematurely as the surgical start time occurred later in the day. A total of 44 different antibiotics were recorded for prophylaxis. Antibiotic prophylaxis was performed in 81% to 94% of cases, however, anywhere from 27% to 54% of all cases did not receive antibiotics in a timely fashion. By delegating implementation of ordered antibiotic prophylaxis to the anesthesia team, timing may be improved and the incidence of postoperative wound infections may decrease.
Agodi, A; Auxilia, F; Barchitta, M; Cristina, M L; D'Alessandro, D; Mura, I; Nobile, M; Pasquarella, C
2015-07-01
Recent studies have shown a higher rate of surgical site infections in hip prosthesis implantation using unidirectional airflow ventilation compared with turbulent ventilation. However, these studies did not measure the air microbial quality of operating theatres (OTs), and assumed it to be compliant with the recommended standards for this ventilation technique. To evaluate airborne microbial contamination in OTs during hip and knee replacement surgery, and compare the findings with values recommended for joint replacement surgery. Air samplings were performed in 28 OTs supplied with unidirectional, turbulent and mixed airflow ventilation. Samples were collected using passive sampling to determine the index of microbial air contamination (IMA). Active sampling was also performed in some of the OTs. The average number of people in the OT and the number of door openings during the sampling period were recorded. In total, 1228 elective prosthesis procedures (60.1% hip and 39.9% knee) were included in this study. Of passive samplings performed during surgical activity in unidirectional airflow ventilation OTs (U-OTs) and mixed airflow OTs (M-OTs), 58.9% and 87.6% had IMA values >2, respectively. Of samplings performed during surgical activity in turbulent airflow OTs (T-OTs) and in turbulent airflow OTs with the surgical team wearing Steri-Shield Turbo Helmets (TH-OTs), 8.6% and 60% had IMA values ≤ 2, respectively. Positive correlation was found between IMA values and the number of people in the OT and the number of door openings (P < 0.001). In addition, correlation was found between active and passive sampling (P < 0.001). These findings challenge the belief that unidirectional systems always provide acceptable airborne bacterial counts. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Webster, F; Perruccio, A V; Jenkinson, R; Jaglal, S; Schemitsch, E; Waddell, J P; Venkataramanan, V; Bytautas, J; Davis, A M
2015-06-01
Numerous studies report large and significant improvements in basic mobility and activities of daily living following total hip or knee replacement (TJR). Nevertheless, quantitative research has shown minimal increase in participation in activities that benefit overall health. This study explored why people do or do not engage in activities following hip or knee TJR. This was a longitudinal qualitative study. Sampling was guided by constructivist grounded theory and data collected using open-ended, semi-structured interviews. Participants were recruited using maximum variation sampling based on age, sex and joint replaced (hip or knee). Data were analysed using a constant comparative approach and coded for thematic patterns and relationships from which overarching themes were constructed. Twenty-nine patients participated in interviews prior to, and 8 and 18 months post following TJR. A high degree of variability with regard to participants' return to activities was found and five emergent themes were identified that accounted for this variability. These themes highlight the importance of issues beyond medical factors alone, such as socio-cultural factors that partially determine participants' participation in activity following TJR. Findings suggest that multi-faceted experiences impact participation in activity following TJR. These experiences include changes in identity and lifestyle that preclude a 'return to normal'. There is an urgent need for supports to increase people's activity post-TJR in order to facilitate enhancement of post-surgery levels of engagement. Approaches that take into consideration more personalized interventions may be critical to promoting healthy aging in people with TJR. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Physiotherapy rehabilitation after total knee or hip replacement: an evidence-based analysis.
2005-01-01
The objective of this health technology policy analysis was to determine, where, how, and when physiotherapy services are best delivered to optimize functional outcomes for patients after they undergo primary (first-time) total hip replacement or total knee replacement, and to determine the Ontario-specific economic impact of the best delivery strategy. The objectives of the systematic review were as follows: To determine the effectiveness of inpatient physiotherapy after discharge from an acute care hospital compared with outpatient physiotherapy delivered in either a clinic-based or home-based setting for primary total joint replacement patientsTo determine the effectiveness of outpatient physiotherapy delivered by a physiotherapist in either a clinic-based or home-based setting in addition to a home exercise program compared with a home exercise program alone for primary total joint replacement patientsTo determine the effectiveness of preoperative exercise for people who are scheduled to receive primary total knee or hip replacement surgery Total hip replacements and total knee replacements are among the most commonly performed surgical procedures in Ontario. Physiotherapy rehabilitation after first-time total hip or knee replacement surgery is accepted as the standard and essential treatment. The aim is to maximize a person's functionality and independence and minimize complications such as hip dislocation (for hip replacements), wound infection, deep vein thrombosis, and pulmonary embolism. THE THERAPY: The physiotherapy rehabilitation routine has 4 components: therapeutic exercise, transfer training, gait training, and instruction in the activities of daily living. Physiotherapy rehabilitation for people who have had total joint replacement surgery varies in where, how, and when it is delivered. In Ontario, after discharge from an acute care hospital, people who have had a primary total knee or hip replacement may receive inpatient or outpatient physiotherapy. Inpatient physiotherapy is delivered in a rehabilitation hospital or specialized hospital unit. Outpatient physiotherapy is done either in an outpatient clinic (clinic-based) or in the person's home (home-based). Home-based physiotherapy may include practising an exercise program at home with or without supplemental support from a physiotherapist. Finally, physiotherapy rehabilitation may be administered at several points after surgery, including immediately postoperatively (within the first 5 days) and in the early recovery period (within the first 3 months) after discharge. There is a growing interest in whether physiotherapy should start before surgery. A variety of practises exist, and evidence regarding the optimal pre- and post-acute course of rehabilitation to obtain the best outcomes is needed. The Medical Advisory Secretariat used its standard search strategy, which included searching the databases of Ovid MEDLINE, CINHAL, EMBASE, Cochrane Database of Systematic Reviews, and PEDro from 1995 to 2005. English-language articles including systematic reviews, randomized controlled trials (RCTs), non-RCTs, and studies with a sample size of greater than 10 patients were included. Studies had to include patients undergoing primary total hip or total knee replacement, aged 18 years of age or older, and they had to have investigated one of the following comparisons: inpatient rehabilitation versus outpatient (clinic- or home-based therapy) rehabilitation, land-based post-acute care physiotherapy delivered by a physiotherapist compared with patient self-administered exercise and a land-based exercise program before surgery. The primary outcome was postoperative physical functioning. Secondary outcomes included the patient's assessment of therapeutic effect (overall improvement), perceived pain intensity, health services utilization, treatment side effects, and adverse events The quality of the methods of the included studies was assessed using the criteria outlined in the Cochrane Musculoskeletal Injuries Group Quality Assessment Tool. After this, a summary of the biases threatening study validity was determined. Four methodological biases were considered: selection bias, performance bias, attrition bias, and detection bias. A meta-analysis was conducted when adequate data were available from 2 or more studies and where there was no statistical or clinical heterogeneity among studies. The GRADE system was used to summarize the overall quality of evidence. The search yielded 422 citations; of these, 12 were included in the review including 10 primary studies (9 RCTs, 1 non-RCT) and 2 systematic reviews. The Medical Advisory Secretariat review included 2 primary studies (N = 334) that examined the effectiveness of an inpatient physiotherapy rehabilitation program compared with an outpatient home-based physiotherapy program on functional outcomes after total knee or hip replacement surgery. One study, available only as an abstract, found no difference in functional outcome at 1 year after surgery (TKR or THR) between the treatments. The other study was an observational study that found that patients who are younger than 71 years of age on average, who do not live alone, and who do not have comorbid illnesses recover adequate function with outpatient home-based physiotherapy. However results were only measured up to 3 months after surgery, and the outcome measure they used is not considered the best one for physical functioning. Three primary studies (N = 360) were reviewed that tested the effectiveness of outpatient home-based or clinic-based physiotherapy in addition to a self-administered home exercise program, compared with a self-administered exercise program only or in addition to using another therapy (phone calls or continuous passive movement), on postoperative physical functioning after primary TKR surgery. Two of the studies reported no difference in change from baseline in flexion range of motion between those patients receiving outpatient or home-based physiotherapy and doing a home exercise program compared with patients who did a home exercise program only with or without continuous passive movement. The other study reported no difference in the Western Ontario and McMaster Osteoarthritis Index (WOMAC) scores between patients receiving clinic-based physiotherapy and practising a home exercise program and those who received monitoring phone calls and did a home exercise program after TKR surgery. The Medical Advisory Secretariat reviewed two systematic reviews evaluating the effects of preoperative exercise on postoperative physical functioning. One concluded that preoperative exercise is not effective in improving functional recovery or pain after TKR and any effects after THR could not be adequately determined. The other concluded that there was inconclusive evidence to determine the benefits of preoperative exercise on functional recovery after TKR. Because 2 primary studies were added to the published literature since the publication of these systematic reviews the Medical Advisory Secretariat revisited the question of effectiveness of a preoperative exercise program for patients scheduled for TKR ad THR surgery. The Medical Advisory Secretariat also reviewed 3 primary studies (N = 184) that tested the effectiveness of preoperative exercise beginning 4-6 weeks before surgery on postoperative outcomes after primary TKR surgery. All 3 studies reported negative findings with regard to the effectiveness of preoperative exercise to improve physical functioning after TKR surgery. However, 2 failed to show an effect of the preoperative exercise program before surgery in those patients receiving preoperative exercise. The third study did not measure functional outcome immediately before surgery in the preoperative exercise treatment group; therefore the study's authors could not document an effect of the preoperative exercise program before surgery. Regarding health services utilization, 2 of the studies did not find significant differences in either the length of the acute care hospital stay or the inpatient rehabilitation care setting between patients treated with a preoperative exercise program and those not treated. The third study did not measure health services utilization. These results must be interpreted within the limitations and the biases of each study. Negative results do not necessarily support a lack of treatment effect but may be attributed to a type II statistical error. Finally, the Medical Advisory Secretariat reviewed 2 primary studies (N = 136) that examined the effectiveness of preoperative exercise on postoperative functional outcomes after primary THR surgery. One study did not support the effectiveness of an exercise program beginning 8 weeks before surgery. However, results from the other did support the effectiveness of an exercise program 8 weeks before primary THR surgery on pain and functional outcomes 1 week before and 3 weeks after surgery. Based on the evidence, the Medical Advisory Secretariat reached the following conclusions with respect to physiotherapy rehabilitation and physical functioning 1 year after primary TKR or THR surgery: There is high-quality evidence from 1 large RCT to support the use of home-based physiotherapy instead of inpatient physiotherapy after primary THR or TKR surgery.There is low-to-moderate quality evidence from 1 large RCT to support the conclusion that receiving a monitoring phone call from a physiotherapist and practising home exercises is comparable to receiving clinic-based physiotherapy and practising home exercises for people who have had primary TKR surgery. However, results may not be generalizable to those who have had THR surgery.There is moderate evidence to suggest that an exercise program beginning 4 to 6 weeks before primary TKR surgery is not effective. (ABSTRACT TRUNCATED)
Factors influencing return to work after hip and knee replacement.
Malviya, A; Wilson, G; Kleim, B; Kurtz, S M; Deehan, D
2014-09-01
Return to employment is one of the key goals of joint replacement surgery in the working-age population. There is limited quantitative and qualitative research focusing on return to work after hip and knee replacement. It remains unclear why certain groups of patients are not able to achieve sufficient functional improvement to allow productive return to work while others can. Very little is known about the individual patient and employer perspectives in this regard. To review current evidence for the factors influencing employment outcomes in patients undergoing hip and knee replacement. Original articles and reviews in Medline, Embase and PsycINFO from 1987 to 2013 were included in the analysis. Age, patient motivation, employment before surgery and type of job were found to be important factors in determining return to work following hip and knee replacement. There is a need for further qualitative work on how and why these factors influence employment outcomes. © The Author 2014. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Osmanski-Zenk, K; Steinig, N S; Glass, Ä; Mittelmeier, W; Bader, R
2015-12-01
As the need for joint replacements will continue to rise, the outcome of primary total hip replacement (THR) must be improved and stabilised at a high level. In this study, we investigated whether pre-operative risk factors, such as gender, age and body weight at the time of the surgery or a restricted physical status (ASA-Status > 2 or Kellgren and Lawrence grade > 2) have a negative influence on the post-operative results or on patient satisfaction. Retrospective data collection and a prospective interview were performed with 486 patients who underwent primary total hip replacement between January 2007 and December 2010 in our hospital. The patients' satisfaction and quality of life were surveyed with the WOMAC-Score, SF-36 and EuroQol-5. Differences between more than two independent spot tests were tested with the non-parametric Kruskal-Wallis test. Differences between two independent spot tests were tested with the non-parametric Mann-Whitney U test. The frequencies were reported and odds ratios calculated. The confidence interval was set at 95 %. The level of significance was p < 0.05. The average WOMAC-Score was 77.1 and the total score of the SF-36 was 66.9 points. The patients declared an average EuroQol Index of 0.81. Our data show that the patients' gender did not influence the duration of surgery or the scores. However, female patients tended to exhibit more postoperative complications. However, increased patient age at the time of surgery was associated with an increased OR for duration of surgery, length of stay and risk of complications. Patients who had a normal body weight at time of the surgery showed better peri- and post-operative results. We showed that the preoperative estimated Kellgren and Lawrence grade had a significant influence on the duration of surgery. The ASA classification influenced the duration of surgery as well the length of stay and the rate of complications. The quality of results after primary THR depends on preoperative factors. Existing comorbidities have a significant influence on the duration of surgery and therefore on the perioperative rate of complications and the postoperative outcome. Despite improvements in the functional and subjective outcome after primary THR, an adverse preoperative symptomatic status is associated with less favourable postoperative results. Georg Thieme Verlag KG Stuttgart · New York.
Gavin, James P; Immins, Tikki; Wainwright, Thomas
2017-05-01
Total hip replacement (THR) and total knee replacement (TKR) are common orthopaedic procedures. However, an optimal programme for post-operative rehabilitation has yet to be established. Stair negotiation is a challenging, habitual task, regularly used as a post-operative functional outcome measure; yet as a physical rehabilitation intervention it appears to be rarely used. The review purpose was to investigate the effectiveness of stair climbing as a rehabilitation intervention for THR and TKR patients. MEDLINE, PsycINFO, Science Citation Index, CINAHL, SPORTDiscus and the Cochrane Database of Systematic Reviews were searched. The systematic review targeted studies using stair negotiation as a rehabilitation intervention. Randomised and non-randomised controlled trials, pilot studies, and case studies were included; systematic reviews and meta-analyses were excluded. Of 650 articles identified, ten studies were eligible for review. A predefined data table to extract information from selected studies was used. Of the ten identified reports, two prehabilitation and eight rehabilitation studies included stair negotiation exercises as part of multi-modal physical interventions. Outcome measures were classified as: functional self-reported, perceptual, psychological and those relating to quality of life. Studies were methodologically heterogeneous and typically lacked adequate control groups. It was not possible to determine the impact of stair negotiation exercise on the positive outcomes of interventions. Stair negotiation warrants further investigation as a rehabilitation activity. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.
Dahm, P O; Nitescu, P V; Appelgren, L K; Curelaru, I D
1998-01-01
There is at present no reliable method for long-term treatment of severe pain following complications of total hip arthroplasty. We explored the long-term use of continuous intrathecal opioid/bupivacaine analgesia in a case not amendable to corrective surgery. A 77-year-old woman, having a total hip arthroplasty, developed refractory nociceptive-neuropathic pain located at the ventral and dorsal aspects of the left hip. Radiographs showed a mandarine-sized intrapelvic mass of bone cement adhering to the roof of the acetabular cup. Further surgery had been declined by the surgeon and by the patient. An 18-gauge Portex intrathecal catheter was inserted, and an intrathecal infusion of 4.75 mg/mL bupivacaine and 0.015 mg/mL buprenorphine was started from a portable Pharmacia-Deltec (St. Paul, Minnesota) pump. The mean daily doses during the treatment period (more than 6 years up to now) were 37 mg for bupivacaine and 0.114 mg for buprenorphine. The intrathecal treatment gave the patient 85-100% pain relief. The patient could transport herself in a wheelchair, was able to perform her own hygiene, receive visits, read, watch television, and also shop and visit restaurants. There has been no need to replace the intrathecal catheter. Intrathecal infusion of opioid/bupivacaine can provide satisfactory long-term analgesia in patients with refractory pain from the hip joint.
Marcus-Aiyeku, Ulanda; DeBari, Margaret; Salmond, Susan
2015-01-01
In 2030, when baby boomers reach 65 years of age and represent 18% of the population, it is anticipated that 67 million adults will have a diagnosis of arthritis increasing the demand for total hip and knee arthroplasty. With the growing emphasis on patient- and family-centered care, the aim of this project was to assess the patient experience of patients and families throughout the entire spectrum of the total joint replacement service line care at a university regional trauma hospital. A shadowing methodology as defined by the Institute for Health Improvement was utilized. Eight patient/family groups undergoing total joint replacements were shadowed. The mapped care experience included time, caregiver, activity, shadower observations, and impressions. Findings revealed inconsistencies in the delivery of patient- and family-centered care. Communication and interactions were predominantly provider-centric, with a focus on care routines versus the patient and family, and anticipation that care would be medically directed.
Barr, Andrew J; Campbell, T Mark; Hopkinson, Devan; Kingsbury, Sarah R; Bowes, Mike A; Conaghan, Philip G
2015-08-25
Bone is an integral part of the osteoarthritis (OA) process. We conducted a systematic literature review in order to understand the relationship between non-conventional radiographic imaging of subchondral bone, pain, structural pathology and joint replacement in peripheral joint OA. A search of the Medline, EMBASE and Cochrane library databases was performed for original articles reporting association between non-conventional radiographic imaging-assessed subchondral bone pathologies and joint replacement, pain or structural progression in knee, hip, hand, ankle and foot OA. Each association was qualitatively characterised by a synthesis of the data from each analysis based upon study design, adequacy of covariate adjustment and quality scoring. In total 2456 abstracts were screened and 139 papers were included (70 cross-sectional, 71 longitudinal analyses; 116 knee, 15 hip, six hand, two ankle and involved 113 MRI, eight DXA, four CT, eight scintigraphic and eight 2D shape analyses). BMLs, osteophytes and bone shape were independently associated with structural progression or joint replacement. BMLs and bone shape were independently associated with longitudinal change in pain and incident frequent knee pain respectively. Subchondral bone features have independent associations with structural progression, pain and joint replacement in peripheral OA in the hip and hand but especially in the knee. For peripheral OA sites other than the knee, there are fewer associations and independent associations of bone pathologies with these important OA outcomes which may reflect fewer studies; for example the foot and ankle were poorly studied. Subchondral OA bone appears to be a relevant therapeutic target. PROSPERO registration number: CRD 42013005009.
Clinico-radiological diagnosis and grading of rapidly progressive osteoarthritis of the hip.
Zazgyva, Ancuţa; Gurzu, Simona; Gergely, István; Jung, Ioan; Roman, Ciprian O; Pop, Tudor S
2017-03-01
Due to the current lack of standard definitions for rapidly progressive osteoarthritis of the hip (RPOH) in the literature, this observational study aimed to describe new diagnostic criteria and a grading system for the disease.From a consecutive series of patients undergoing total hip replacement, 2 groups were selected: 1 with RPOH and 1 with primary hip osteoarthritis (POH), and their clinical, paraclinical, and demographic data were compared. The newly proposed clinico-radiological diagnostic criteria are based on characteristics of pain, joint mobility, and radiological assessment. The radiological grading system's inter- and intraobserver reliability was assessed through serial evaluations by 2 blinded reviewers.From the total 863 cases, 82 cases (9.5%) of RPOH were identified and compared with 107 cases of POH. Mean age and disease bilaterality were similar, with a predominance of female patients in the RPOH group (P = 0.03). There were significant differences between the 2 groups in disease onset and aggravation, and intraoperative blood loss. The grading system showed significant inter- and intraobserver agreement (weighted kappa 0.93, and 0.89).Our study presents distinctive, easily recognizable clinico-radiological characteristics of RPOH and confirmed the inter- and intraobserver reliability of the newly proposed grading system.
[Total hip replacement with isoelastic prosthesis in animals (author's transl)].
Muhr, O; Stockhusen, H; Müller, O
1976-10-08
Uncemented fixation and low-fraction materials are the basis of this experiment. Plastics with an elasticity similar to the bone ("isoelasticity") show very propitious material qualities. The direct cementless incorporation of test bodies must be checked. In 63 sheep isoelastic total hip joints were implanted. After 2 till 51 weeks the animals were sacrificed and 44 specimen of hips and organs were explored macroscopically, radiologically, spherimetrically and histologically. The result was: 1. Plastic hip prosthesis are incorporated in the bone, but the boundary layer is built by a collagenous fiber tissue. 2. Loosening brings resoption of the bone and expansion of the structural changed soft tissue. 3. The transformation of the femoral cortex to osteoporosis is considered possibly as the consequence of an insufficient biological transfer of the weight. 4. Fractures of the femoral prosthesis-stem could not be observed. 5. The radiology allows at the pelvis prosthesis a concret statement concerning stability, on the femoral part a probable one. 6. The abrasion is minimal, the tissue reaction to abrasion products is unessential. 7. Small abrasion particles are carried of by the lymph tract and stored in the first regional gland. A more distant spreading is not demonstrable.
The effect of tibiotalar alignment on coronal plane mechanics following total ankle replacement.
Grier, A Jordan; Schmitt, Abigail C; Adams, Samuel B; Queen, Robin M
2016-07-01
Gait mechanics following total ankle replacement (TAR) have reported improved ankle motion following surgery. However, no studies have addressed the impact of preoperative radiographic tibiotalar alignment on post-TAR gait mechanics. We therefore investigated whether preoperative tibiotalar alignment (varus, valgus, or neutral) resulted in significantly different coronal plane mechanics or ground reaction forces post-TAR. We conducted a non-randomized study of 93 consecutive end-stage ankle arthritis patients. Standard weight-bearing radiographs were obtained preoperatively to categorize patients as having neutral (±4°), varus (≥5° of varus), or valgus (≥5° of valgus) coronal plane tibiotalar alignment. All patients underwent a standard walking assessment including three-dimensional lower extremity kinetics and kinematics preoperatively, 12 and 24 months postoperatively. A significant group by time interaction was observed for the propulsive vertical ground reaction force (vGRF), coronal plane hip range of motion (ROM) and the peak hip abduction moment. The valgus group demonstrated an increase in the peak knee adduction angle and knee adduction angle at heel strike when compared to the other groups. Coronal plane ankle ROM, knee and hip angles at heel strike, and the peak hip angle exhibited significant increases across time. Peak ankle inversion moment, peak knee abduction moment and the weight acceptance vGRF also exhibited significant increases across time. Neutral ankle alignment was achieved for all patients by 2 years following TAR. Restoration of neutral ankle alignment at the time of TAR in patients with preoperative varus or valgus tibiotalar alignment resulted in biomechanics similar to those of patients with neutral preoperative tibiotalar alignment by 24-month follow-up. Copyright © 2016 Elsevier B.V. All rights reserved.
Barr, Rebecca J; Gregory, Jennifer S; Reid, David M; Aspden, Richard M; Yoshida, Kanako; Hosie, Gillian; Silman, Alan J; Alesci, Salvatore; Macfarlane, Gary J
2012-03-01
Previously, active shape modelling (ASM) of the proximal femur was shown to identify those individuals at highest risk of developing radiographic OA. Here we determine whether ASM predicts the need for total hip replacement (THR) independent of Kellgren-Lawrence grade (KLG) and other known risk factors. A retrospective cohort study of 141 subjects consulting primary care with new hip pain was conducted. Pelvic radiographs taken on recruitment were assessed for KLG, centre-edge angle, acetabular depth and femoral head migration. Clinical factors (duration of pain, use of a stick and physical function) were collected by self-completed questionnaires. ASM differences between shape mode scores at baseline for individuals who underwent THR during the 5-year follow-up (n = 27) and those whose OA did not progress radiographically (n = 75) were compared. A 1 s.d. reduction in baseline ASM mode 2 score was associated with an 81% reduction in odds of THR (OR = 0.19, 95% CI 0.52, 0.70) after adjustment for KLG, radiographic and clinical factors. A similar reduction in odds of THR was associated with a 1 s.d. reduction in mode 3 (OR = 0.45, 95% CI 0.28, 0.71) and a 1 s.d. increase in mode 4 score (OR = 2.8, 95% CI 1.7, 4.7), although these associations were no longer significant after adjustment for KLG and clinical factors. ASM of the hip joint is a reliable early biomarker of radiographic OA severity, which can improve the ability to identify patients at higher risk of rapid progression and poor outcome even when KLG and clinical risk factors are taken into account.
Blasimann, Angela; Dauphinee, Sharon Wood; Staal, J Bart
2014-12-01
Clinical measurement. To translate and cross-culturally adapt the Hip disability and Osteoarthritis Outcome Score (HOOS) from English into German, and to study its psychometric properties in patients after hip surgery. There is no specific hip questionnaire in German that not only measures symptoms and function but also contains items about hip-related quality of life. The translation and cross-cultural adaptation involved forward translation, harmonization, cognitive debriefing, back translation, and comparison to the original HOOS following international guidelines. The German version was tested in 51 Swiss inpatients 8 weeks after different types of hip surgery, mainly total hip replacement. The mean age of the participants was 62.5 years, and the age range was from 27 to 87 years. Thirty (58.8%) of the participants were women. Internal consistency and test-retest reliability were estimated using Cronbach alpha and intraclass correlation coefficients for agreement. For construct validity, total scores of the German HOOS were correlated with those of the Western Ontario and McMaster Universities Osteoarthritis Index. The HOOS was also compared to the Medical Outcomes Study 36-Item Short-Form Health Survey. Cronbach alpha values for all German HOOS subscales were between .87 and .93. For test-retest reliability, the intraclass correlation coefficient for agreement was 0.85 for the total scores of the German HOOS. The Spearman rho for the Medical Outcomes Study 36-Item Short-Form Health Survey physical functioning subscale compared to the sum of all HOOS subscales was 0.71, and that for the Medical Outcomes Study 36-Item Short-Form Health Survey physical component summary was 0.97. The German HOOS has demonstrated adequate reliability and validity. Use of the German HOOS is recommended for assessment of patients after hip surgery, with the proviso that additional psychometric testing should be done in future research.
Postoperative Changes in In Vivo Measured Friction in Total Hip Joint Prosthesis during Walking
Damm, Philipp; Bender, Alwina; Bergmann, Georg
2015-01-01
Loosening of the artificial cup and inlay is the most common reasons for total hip replacement failures. Polyethylene wear and aseptic loosening are frequent reasons. Furthermore, over the past few decades, the population of patients receiving total hip replacements has become younger and more active. Hence, a higher level of activity may include an increased risk of implant loosening as a result of friction-induced wear. In this study, an instrumented hip implant was used to measure the contact forces and friction moments in vivo during walking. Subsequently, the three-dimensional coefficient of friction in vivo was calculated over the whole gait cycle. Measurements were collected from ten subjects at several time points between three and twelve months postoperative. No significant change in the average resultant contact force was observed between three and twelve months postoperative. In contrast, a significant decrease of up to 47% was observed in the friction moment. The coefficient of friction also decreased over postoperative time on average. These changes may be caused by ‘running-in’ effects of the gliding components or by the improved lubricating properties of the synovia. Because the walking velocity and contact forces were found to be nearly constant during the observed period, the decrease in friction moment suggests an increase in fluid viscosity. The peak values of the contact force individually varied by 32%-44%. The friction moment individually differed much more, by 110%-129% at three and up to 451% at twelve months postoperative. The maximum coefficient of friction showed the highest individual variability, about 100% at three and up to 914% at twelve months after surgery. These individual variations in the friction parameters were most likely due to different ‘running-in’ effects that were influenced by the individual activity levels and synovia properties. PMID:25806805
Hoggett, L; Cross, C; Helm, T
2017-12-01
Dislocation after total hip arthroplasty (THA) remains a significant complication of the procedure and is the third leading cause for revision THA. One technique for treatment of this complication is the use of the posterior lip augmentation device (PLAD). We describe our experience using the PLAD including complication rates. A retrospective review of 55 PLADs (54 patients) was carried out following identification from electronic theatre records. Basic patient demographics, operative records and radiographs were collected and reviewed and data was analysed using Microsoft Excel. Failure of the PLAD was defined as further operative intervention after PLAD insertion and included: dislocation, implant breakage, infection and revision of the THA for loosening of either component. 55 PLADs were implanted in 54 patients with an average age of 77 years. There was a significant preponderance of females and a variety of surgical approaches had been used for the original hip replacement, including trochanteric osteotomy, posterior and antero-lateral. 9 (16%) patients had recurrent dislocations,1 (2%) failed secondary to screw breakage, 3 (5%) had and infection requiring intervention and 2 (4%) underwent further revision for aseptic loosening of the femoral component. The overall failure rate was 25% with 14 patients requiring intervention post PLAD. Our results are inferior to other published results and indicate that the PLAD should be used with caution for recurrent dislocations of the Charnley hip replacement.
Madanat, Rami; Hussey, Daniel K; Donahue, Gabrielle S; Potter, Hollis G; Wallace, Robert; Bragdon, Charles R; Muratoglu, Orhun K; Malchau, Henrik
2015-10-01
The purpose of this study was to evaluate whether patients with bilateral metal-on-metal (MoM) hip replacements have symmetric adverse local tissue reactions (ALTRs) at follow-up. An MRI of both hips was performed at a mean time of six years after surgery in 43 patients. The prevalence and severity of ALTRs were found to be similar in simultaneous hips but differences were observed in sequential hips. The order and timing of sequential hip arthroplasties did not affect the severity of ALTRs. Thus, in addition to metal ion exposure from an earlier MoM implant other factors may also play a role in the progression of ALTRs. Bilateral implants should be given special consideration in risk stratification algorithms for management of patients with MoM hip arthroplasty. Copyright © 2015 Elsevier Inc. All rights reserved.
How can the impact of PACS on inpatient length of hospital stay be established?
NASA Astrophysics Data System (ADS)
Bryan, Stirling; Muris, Nicole; Keen, Justin; Weatherburn, Gwyneth C.; Buxton, Martin J.
1994-05-01
Many have argued that the introduction of a large-scale PACS system into a hospital will bring about reductions in the length of inpatient hospital stays. There is currently no convicting empirical evidence to support such claims. As part of the independent evaluation exercise being undertaken alongside the Hammersmith Hospital PACS implementation, an assessment is being made of the impact of PACS on length of stay for selected patient groups. This paper reports the general research methods being employed to undertake this assessment and provides some baseline results from the analysis of total hip replacement patients and total knee replacement patients treated prior to the introduction of PACS.
Harrington, Chris F; McKibbin, Craig; Rahanu, Monika; Langton, David; Taylor, Andrew
2017-05-01
Background Patients with metal-on-metal hip replacements require testing for cobalt and chromium. There may also be a need to test for titanium, which is used in the construction of the femoral stem in total hip replacements. It is not possible to use quadrupole inductively coupled plasma mass spectrometry due to interferences. Methods Titanium was measured using inductively coupled plasma optical emission spectroscopy using the emission line at 336.1 nm and Y (internal standard) at 371.0 nm. Internal quality control materials were prepared for blood and serum and concentrations assigned using a sector field-inductively coupled plasma mass spectrometer. A candidate whole blood certified reference material was also evaluated. Results The method had detection and quantitation limits of 0.6 and 1.9 µg/L, respectively. The respective bias (%) and measurement uncertainty ( U) (k = 2) were 3.3% and 2.0 µg/L (serum) and - 1.0% and 1.4 µg/L (whole blood). The respective repeatability and intermediate precision (%) were 5.1% and 10.9% (serum) and 2.4% and 8.6% (whole blood). The concentration of titanium was determined in patients' samples, serum (median = 2.4 µg/L, n = 897) and whole blood (median = 2.4 µg/L, n = 189). Serum is recommended for monitoring titanium in patients, since the concentration is higher than in whole blood and the matrix less problematic. In hip fluid samples, the concentrations were much higher (mean 58.5 µg/L, median 5.1 µg/L, n = 83). Conclusions A method based on inductively coupled plasma optical emission spectroscopy was developed and validated for measuring titanium in clinical samples.
Brantingham, James W; Parkin-Smith, Gregory; Cassa, Tammy Kay; Globe, Gary A; Globe, Denise; Pollard, Henry; deLuca, Katie; Jensen, Muffit; Mayer, Stephan; Korporaal, Charmaine
2012-02-01
To determine the short-term effectiveness of full kinematic chain manual and manipulative therapy (MMT) plus exercise compared with targeted hip MMT plus exercise for symptomatic mild to moderate hip osteoarthritis (OA). Parallel-group randomized trial with 3-month follow-up. Two chiropractic outpatient teaching clinics. Convenience sample of eligible participants (N=111) with symptomatic hip OA were consented and randomly allocated to receive either the experimental or comparison treatment, respectively. Participants in the experimental group received full kinematic chain MMT plus exercise while those in the comparison group received targeted hip MMT plus exercise. Participants in both groups received 9 treatments over a 5-week period. Western Ontario and McMasters Osteoarthritis Index (WOMAC), Harris hip score (HHS), and Overall Therapy Effectiveness, alongside estimation of clinically meaningful outcomes. Total dropout was 9% (n=10) with 7% of total data missing, replaced using a multiple imputation method. No statistically significant differences were found between the 2 groups for any of the outcome measures (analysis of covariance, P=.45 and P=.79 for the WOMAC and HHS, respectively). There were no statistically significant differences in the primary or secondary outcome scores when comparing full kinematic chain MMT plus exercise with targeted hip MMT plus exercise for mild to moderate symptomatic hip OA. Consequently, the nonsignificant findings suggest that there would also be no clinically meaningful difference between the 2 groups. The results of this study provides guidance to musculoskeletal practitioners who regularly use MMT that the full kinematic chain approach does not appear to have any benefit over targeted treatment. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Chu, Janet N; Maselli, Judith; Auerbach, Andrew D; Fang, Margaret C
2017-07-01
Recent guidelines include aspirin as an option to prevent venous thromboembolism (VTE) in selected patients undergoing hip or knee replacement surgery. However, the efficacy of aspirin after arthroplasty has not been well-defined, particularly in more contemporary patient populations. We compared rates of post-operative VTE between patients who received aspirin-only versus anticoagulants after hip or knee arthroplasty, using data from a large US-based administrative database. We conducted a retrospective cohort study of 231,780 adults who underwent total knee arthroplasty and 110,621 who underwent total hip arthroplasty in 2009-2012 and who received pharmacologic VTE prophylaxis (aspirin or anticoagulant) within the first 7days after surgery. We compared the risk of post-operative VTE between patients receiving aspirin-only vs. anticoagulants, controlling for clinical and hospital characteristics using multivariable logistic regression with propensity score adjustment. Aspirin-only prophylaxis was administered to 7.5% of patients after knee arthroplasty and 8.0% after hip arthroplasty. Post-operative VTE was diagnosed in 2217 (0.96%) patients after knee arthroplasty and 454 (0.41%) after hip arthroplasty. Compared to anticoagulants, aspirin was not associated with a higher risk for post-operative VTE either after knee arthroplasty (adjusted odds ratio and 95% confidence interval [OR] 0.34 [0.24-0.48]) or hip arthroplasty (OR 0.82 [0.45-1.51]). Aspirin was uncommonly administered as the sole prophylactic agent after hip or knee arthroplasty in this study. However, patients who received aspirin-only had similar rates of post-operative VTE compared to patients who received anticoagulants. Further research should focus on distinguishing which patients benefit more from anticoagulants versus aspirin after arthroplasty. Copyright © 2017 Elsevier Ltd. All rights reserved.
Molloy, Ilda B; Martin, Brook I; Moschetti, Wayne E; Jevsevar, David S
2017-03-01
Utilization of total knee and hip arthroplasty has greatly increased in the past decade in the United States; these are among the most expensive procedures in patients with Medicare. Advances in surgical techniques, anesthesia, and care pathways decrease hospital length of stay. We examined how trends in hospital cost were altered by decreases in length of stay. Procedure, demographic, and economic data were collected on 6.4 million admissions for total knee arthroplasty and 2.8 million admissions for total hip arthroplasty from 2002 to 2013 using the National (Nationwide) Inpatient Sample, a component of the Healthcare Cost and Utilization Project. Trends in mean hospital costs and their association with length of stay were estimated using inflation-adjusted, survey-weighted generalized linear regression models, controlling for patient demographic characteristics and comorbidity. From 2002 to 2013, the length of stay decreased from a mean time of 4.06 to 2.97 days for total knee arthroplasty and from 4.06 to 2.75 days for total hip arthroplasty. During the same time period, the mean hospital cost for total knee arthroplasty increased from $14,988 (95% confidence interval [CI], $14,927 to $15,049) in 2002 to $22,837 (95% CI, $22,765 to $22,910) in 2013 (an overall increase of $7,849 or 52.4%). The mean hospital cost for total hip arthroplasty increased from $15,792 (95% CI, $15,706 to $15,878) in 2002 to $23,650 (95% CI, $23,544 to $23,755) in 2013 (an increase of $7,858 or 49.8%). If length of stay were set at the 2002 mean, the growth in cost for total knee arthroplasty would have been 70.8% instead of 52.4% as observed, and the growth in cost for total hip arthroplasty would have been 67.4% instead of 49.8% as observed. Hospital costs for joint replacement increased from 2002 to 2013, but were attenuated by reducing inpatient length of stay. With demographic characteristics showing an upward trend in the utilization of joint arthroplasty, including a shift toward younger population groups, reduction in length of stay remains an important target for procedure-level cost containment under emerging payment models.
A patterned microtexture to reduce friction and increase longevity of prosthetic hip joints
Chyr, Anthony; Qiu, Mingfeng; Speltz, Jared; Jacobsen, Ronald L.; Sanders, Anthony P.; Raeymaekers, Bart
2014-01-01
More than 285,000 total hip replacement surgeries are performed in the US each year. Most prosthetic hip joints consist of a cobalt-chromium (CoCr) femoral head that articulates with a polyethylene acetabular component, lubricated with synovial fluid. The statistical survivorship of these metal-on-polyethylene prosthetic hip joints declines significantly after 10 to 15 years of use, primarily as a result of polyethylene wear and wear debris incited disease. The current engineering paradigm to increase the longevity of prosthetic hip joints is to improve the mechanical properties of the polyethylene component, and to manufacture ultra-smooth articulating surfaces. In contrast, we show that adding a patterned microtexture to the ultra-smooth CoCr femoral head reduces friction when articulating with the polyethylene acetabular liner. The microtexture increases the load-carrying capacity and the thickness of the joint lubricant film, which reduces contact between the articulating surfaces. As a result, friction and wear is reduced. We have used a lubrication model to design the geometry of the patterned microtexture, and experimentally demonstrate reduced friction for the microtextured compared to conventional smooth surrogate prosthetic hip joints. PMID:25013240
[Juvenile rheumatoid diseases: Endoprosthetic care of destroyed hip joints].
Rehart, S; Henniger, M
2015-07-01
Patients with juvenile idiopathic arthritis (JIA) often suffer from involvement of the hip joints, with joint destruction and related functional limitations, making hip replacement necessary. To discover what special features are to be expected in patients with JIA and hip arthroplasty and what impact they have on surgical indication, choice of implant, and technique. Selective literature review and evaluation of our patient population. Compared with osteoarthritis patients, JIA patients are on average much younger at the time of hip replacement. Owing to the onset of the disease in childhood or adolescence and the frequent glucocorticoid therapy, growth disorders or abnormal anatomical findings are common in these patients. Bone density is often reduced at an early age. The perioperative management of medication has to be planned. Special implants for patients with rheumatic diseases do not exist, but the above peculiarities of this group of patients should be considered for surgical procedure and choice of implant and material. Overall, the results of hip arthroplasty in juvenile rheumatic diseases, in terms of pain relief and functional improvement, are good. The limited life of the arthroplasty is problematic. By relieving pain, improvement of the range of motion and activity level very high patient satisfaction is usually achieved by hip arthroplasty in JIA patients. In the case of involvement of the contralateral hip or the ipsilateral knee joint it may be useful to perform a simultaneous, single-stage joint replacement of both joints.
Russo, Matthew W; Parks, Nancy L; Hamilton, William G
2017-10-01
Multimodal pain management has become the standard of care following total hip and knee replacement. The advantages include decreasing opioid consumption and its associated side effects, facilitating earlier mobilization, and faster return to function. An effective rapid recovery protocol includes the use of multiple different types of medications targeting each area of the pain pathway, preemptive analgesia, regional nerve blockade, and local infiltration analgesia. Copyright © 2017 Elsevier Inc. All rights reserved.
The Role of Hip Arthroscopy in Investigating and Managing the Painful Hip Resurfacing Arthroplasty.
Mei-Dan, Omer; Pascual-Garrido, Cecilia; Moreira, Brett; McConkey, Mark O; Young, David A
2016-03-01
To determine the safety and efficacy of hip arthroscopy performed in the peripheral compartment as a diagnostic and therapeutic treatment option for patients with hip pain after hip resurfacing surgery. Indications for hip arthroscopy after hip resurfacing included patients with a symptomatic hip-resurfaced arthroplasties who did not respond to nonoperative treatment. Patients who underwent a hip arthroscopy after a painful hip resurfacing were included with a minimum of 1 year follow-up. Subgroup analysis was performed according to whether an established diagnosis was made before arthroscopic intervention or not. Subjective measures were based on Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores, and results were calculated and analyzed. We included 68 patients (26 male [38%] and 42 female [62%]) who underwent subsequent hip arthroscopy from a population of 978 consecutive hip-resurfaced arthroplasties performed between 1999 and 2010. The average age was 58 (range, 37 to 78 years). The mean follow-up after hip arthroscopy was 3.4 years (range, 12 months to 5.8 years). Patients who had an established diagnosis (n = 41) before hip arthroscopy showed statistical improvement in their WOMAC scores (7 to 2, P < .001). Only 3 (7%) of these 41 patients failed and were converted to a total hip replacement (THR); however, patients who did not have an established diagnosis (n = 27) before undergoing hip arthroscopy showed statistical worsening of the WOMAC (15 to 21, P = .002). Ten (37%) of these 27 patients without a diagnosis failed and needed to be converted to a THR. A significant correlation was found between the collections found on ultrasound (psoas bursa and/or in the hip joint) and the need for synovectomy (P = .01). The overall revision rate to THR after hip resurfacing in our group of patients was 1.3% (n = 13). Female patients were more likely to require postresurfacing hip arthroscopy with 42 (60%) female to only 26 (40%) male patients undergoing this procedure. In our study population, 70% (14/21, P < .05) of patients with hip pain caused by severe metal synovial reaction or metal-on-metal reaction were women. A total of 5 (7%) patients had minor-to-mild complications after hip arthroscopy. Hip arthroscopy is a safe surgical treatment option for those patients with a painful hip resurfacing arthroplasty. Having an accurate diagnosis before hip arthroscopy improves the likelihood a good outcome. Level IV - therapeutic case series. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Fontaine, Sarah N; Bauer, Scott P; Lin, Xiaoyan; Poorfarahani, Sara; Ybe, Joel A
2012-09-21
HIP1 crystal structures solved in our laboratory revealed abnormalities in the coiled-coil region, suggesting intrinsic plasticity. To test this, specific amino acids in the coiled-coil were mutated. The apparent thermal stability of HIP1 was altered when Thr528 and Glu531 were replaced by leucine, and was enhanced when Lys510 was also mutated. In cells, HIP1 mutant expression produced aggregation. MTS and flow cytometry indicate a correlation between aggregated HIP1 and enhanced cell death. These data support the idea that flexibility of the HIP1 coiled-coil domain is important for normal function and may lead to new insights into Huntington's disease. Copyright © 2012 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved.
[Post-anesthetic autologous blood donation used in knee and hip arthroplasty].
Wei, Wei; Kou, Bolong; Ju, Rongseng
2006-06-01
To explore the clinical application of the postanesthetic autologous donation and the postoperative transfusion during the knee and hip replacement surgeries. Thirty-three patients (17 males, 16 females) admitted for the elective joint replacement surgeries from September 2004 to January 2005 were included in this study. Of the 33 patients, 5 were diagnosed with rheumatoid arthritis, 23 with femoral head necrosis, and 5 with knee osteoarthritis. Immediately after anesthesia, 400 ml of the blood was drawn and transfused after the surgery. The blood pressure was monitored during the blood drawing, postoperative blood parameters were recorded, surgical site drainage and signs of infections were observed, and the other clinical data were collected. Of the 33 patients, 27 only received autologous transfusion, including 21 patients who underwent the unilateral hip replacement and 6 patients who underwent the unilateral knee replacement. All these 6 patients with the unilateral knee replacement received the blood drained from the surgical sites in addition to the blood obtained from the post-anesthetic autologous donation. Another 6 cases with the bilateral hip and knee replacement received the blood drained from the surgical sites, the blood obtained from the post-anesthetic autologous donation and 400 ml of the allogeneic blood transfusion. The blood received postoperatively averaged 650 ml (range, 200-1 150 ml), haemoglobin (Hb) was averaged 88 g/L (68-102 g/L), and Hct was averaged 24.6% (20.5%-31.5%). Hb and Hct were lower after operation than before operation (P < 0.01). Postoperative blood transfusion following the postanesthetic and preoperative autologous donation can be successfully applied to most of the patients undergoing the knee or hip replacement so as to reduce complications of the allogeneic blood transfusion.
Diabetes is associated with persistent pain after hip and knee replacement
Rajamäki, Tuomas J; Jämsen, Esa; Puolakka, Pia A; Nevalainen, Pasi I; Moilanen, Teemu
2015-01-01
Background and purpose In some patients, for unknown reasons pain persists after joint replacement, especially in the knee. We determined the prevalence of persistent pain following primary hip or knee replacement and its association with disorders of glucose metabolism, metabolic syndrome (MetS), and obesity. Patients and methods The incidence of pain in the operated joint was surveyed 1–2 years after primary hip replacement (74 patients (4 bilateral)) or primary knee replacement (119 patients (19 bilateral)) in 193 osteoarthritis patients who had participated in a prospective study on perioperative hyperglycemia. Of the 155 patients who completed the survey, 21 had undergone further joint replacement surgery during the follow-up and were excluded, leaving 134 patients for analysis. Persistent pain was defined as daily pain in the operated joint that had lasted over 3 months. Factors associated with persistent pain were evaluated using binary logistic regression with adjustment for age, sex, and operated joint. Results 49 of the134 patients (37%) had a painful joint and 18 of them (14%) had persistent pain. A greater proportion of knee patients than hip patients had a painful joint (46% vs. 24%; p = 0.01) and persistent pain (20% vs. 4%; p = 0.007). Previously diagnosed diabetes was strongly associated with persistent pain (5/19 vs. 13/115 in those without; adjusted OR = 8, 95% CI: 2–38) whereas MetS and obesity were not. However, severely obese patients (BMI ≥ 35) had a painful joint (but not persistent pain) more often than patients with BMI < 30 (14/21 vs. 18/71; adjusted OR = 5, 95% CI: 2–15). Interpretation Previously diagnosed diabetes is a risk factor for persistent pain in the operated joint 1–2 years after primary hip or knee replacement. PMID:25953426
Chen, Yun-Lin; Lin, Tiao; Liu, An; Shi, Ming-Min; Hu, Bin; Shi, Zhong-Li; Yan, Shi-Gui
2015-01-28
There are some arguments between the use of hydroxyapatite and porous coating. Some studies have shown that there is no difference between these two coatings in total hip arthroplasty (THA), while several other studies have shown that hydroxyapatite has advantages over the porous one. We have collected the studies in Pubmed, MEDLINE, EMBASE, and the Cochrane library from the earliest possible years to present, with the search strategy of "(HA OR hydroxyapatite) AND ((total hip arthroplasty) OR (total hip replacement)) AND (RCT* OR randomiz* OR control* OR compar* OR trial*)". The randomized controlled trials and comparative observation trials that evaluated the clinical and radiographic effects between hydroxyapatite coating and porous coating were included. Our main outcome measurements were Harris hip score (HHS) and survival, while the secondary outcome measurements were osteolysis, radiolucent lines, and polyethylene wear. Twelve RCTs and 9 comparative observation trials were included. Hydroxyapatite coating could improve the HHS (p < 0.01), reduce the incidence of thigh pain (p = 0.01), and reduce the incidence of femoral osteolysis (p = 0.01), but hydroxyapatite coating had no advantages on survival (p = 0.32), polyethylene wear (p = 0.08), and radiolucent lines (p = 0.78). Hydroxyapatite coating has shown to have an advantage over porous coating. The HHS and survival was duration-dependent-if given the sufficient duration of follow-up, hydroxyapatite coating would be better than porous coating for the survival. The properties of hydroxyapatite and the implant design had influence on thigh pain incidence, femoral osteolysis, and polyethylene wear. Thickness of 50 to 80 μm and purity larger than 90% increased the thigh pain incidence. Anatomic design had less polyethylene wear.
Scheller, G; Schwarz, M; Früh, H J; Jani, L
1999-01-01
Hip simulator trials were conducted to determine the initial wear between alumina femoral heads and carbon fibre reinforced plastic (CFRP, CAPROMAN) insert in a titanium socket. A force of 2500 N and a frequency of 0.857 H were applied. Using surface and sphericity measurement techniques, the amount of wear was determined. After 500,000 cycles, the centre of the head had moved by 10 microm into the insert, and the average radius increased by 2 microm. After 1 million cycles, the additional changes were less than 1 microm. Based on an examination of retrieved implants (wear rate: 6.1 microm/year) and based on the simulator results, the combination alumina-CFRP inserts could be approved for total hip replacement.
10-year results of a new low-monomer cement: follow-up of a randomized RSA study.
Söderlund, Per; Dahl, Jon; Röhrl, Stephan; Nivbrant, Bo; Nilsson, Kjell G
2012-12-01
The properties and performance of a new low-monomer cement were examined in this prospective randomized, controlled RSA study. 5-year data have already been published, showing no statistically significant differences compared to controls. In the present paper we present the 10-year results. 44 patients were originally randomized to receive total hip replacement with a Lubinus SPII titanium-aluminum-vanadium stem cemented either with the new Cemex Rx bone cement or with control bone cement, Palacos R. Patients were examined using RSA, Harris hip score, and conventional radiographs. At 10 years, 33 hips could be evaluated clinically and 30 hips could be evaluated with RSA (16 Cemex and 14 Palacos). 9 patients had died and 4 patients were too old or infirm to be investigated. Except for 1 hip that was revised for infection after less than 5 years, no further hips were revised before the 10-year follow-up. There were no statistically significant clinical differences between the groups. The Cemex cement had magnitudes of migration similar to or sometimes lower than those of Palacos cement. In both groups, most hips showed extensive radiolucent lines, probably due to the use of titanium alloy stems. At 10 years, the Cemex bone cement tested performed just as well as the control (Palacos bone cement).
Artifact Reduction in X-Ray CT Images of Al-Steel-Perspex Specimens Mimicking a Hip Prosthesis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Madhogarhia, Manish; Munshi, P.; Lukose, Sijo
2008-09-26
X-ray Computed Tomography (CT) is a relatively new technique developed in the late 1970's, which enables the nondestructive visualization of the internal structure of objects. Beam hardening caused by the polychromatic spectrum is an important problem in X-ray computed tomography (X-CT). It leads to various artifacts in reconstruction images and reduces image quality. In the present work we are considering the Artifact Reduction in Total Hip Prosthesis CT Scan which is a problem of medical imaging. We are trying to reduce the cupping artifact induced by beam hardening as well as metal artifact as they exist in the CT scanmore » of a human hip after the femur is replaced by a metal implant. The correction method for beam hardening used here is based on a previous work. Simulation study for the present problem includes a phantom consisting of mild steel, aluminium and perspex mimicking the photon attenuation properties of a hum hip cross section with metal implant.« less
A rare presentation of haematuria: hip prosthesis in the bladder.
Phan, Yih Chyn; Eli, Nnaemeka; Pillai, Praveen; O'Dair, Jonathan
2018-03-22
An 80-year-old woman presented to our department with visible haematuria and stage II acute kidney injury (AKI). She had stage IIB cervical cancer, for which she received chemotherapy and external beam radiotherapy in 2003. Four years later, she had a left dynamic hip screw for an extracapsular neck of femur fracture following a fall. In 2010, she underwent a right total hip replacement owing to osteoarthritis, and it was subsequently revised in 2012 owing to a right acetabular component failure. In this admission, her AKI improved with intravenous fluid administration and her haematuria settled following catheterisation with a three-way catheter and bladder irrigation with saline. She underwent a flexible cystoscopy which revealed that a part of her right hip prosthesis was in the bladder, having eroded through the right bony pelvis. However, she declined any surgical interventions. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Prometheus payment model: application to hip and knee replacement surgery.
Rastogi, Amita; Mohr, Beth A; Williams, Jeffery O; Soobader, Mah-Jabeen; de Brantes, Francois
2009-10-01
The Prometheus Payment Model offers a potential solution to the failings of the current fee-for-service system and various forms of capitation. At the core of the Prometheus model are evidence-informed case rates (ECRs), which include a bundle of typical services that are informed by evidence and/or expert opinion as well as empirical data analysis, payment based on the severity of patients, and allowances for potentially avoidable complications (PACs) and other provider-specific variations in payer costs. We outline the methods and findings of the hip and knee arthroplasty ECRs with an emphasis on PACs. Of the 2076 commercially insured patients undergoing hip arthroplasty in our study, PAC costs totaled $7.8 million (14% of total costs; n = 699 index PAC stays). Similarly, PAC costs were $12.7 million (14% of total costs; n = 897 index PAC stays) for 3403 patients undergoing knee arthroplasty. By holding the providers clinically and financially responsible for PACs, and by segmenting and quantifying the type of PACs generated during and after the procedure, the Prometheus model creates an opportunity for providers to focus on the reduction of PACs, including readmissions, making the data actionable and turn the waste related to PAC costs into potential savings.
Rapid rehabilitation and recovery with minimally invasive total hip arthroplasty.
Berger, Richard A; Jacobs, Joshua J; Meneghini, R Michael; Della Valle, Craig; Paprosky, Wayne; Rosenberg, Aaron G
2004-12-01
To assess the potential recovery rate of a minimally invasive total hip replacement technique with minimal soft tissue disruption, an accelerated rehabilitation protocol was implemented with weightbearing as tolerated on the day of surgery. One hundred consecutive patients were enrolled in this prospective study. Ninety-seven patients (97%) met all the inpatient physical therapy goals required for discharge to home on the day of surgery; 100% of patients achieved these goals within 23 hours of surgery. Outpatient therapy was initiated in 9% of patients immediately, 62% of patients by 1 week, and all patients by 2 weeks. The mean time to discontinued use of crutches, discontinued use of narcotic pain medications, and resumed driving was 6 days postoperatively. The mean time to return to work was 8 days, discontinued use of any assistive device was 9 days, and resumption of all activities of daily living was 10 days. The mean time to walk (1/2) mile was 16 days. Furthermore, there were no readmissions, no dislocations, and no reoperations. Therefore, a rapid rehabilitation protocol is safe and fulfills the potential benefits of a rapid recovery with minimally invasive total hip arthroplasty.
[The incidence of osteopenia and osteoporosis in patients with cementless total hip arthroplasty].
Lacko, M; Schreierová, D; Čellár, R; Vaško, G
2015-01-01
The aim of the study was to evaluate the incidence of osteopenia and osteoporosis in the patients elected to cementless total hip replacement. The group evaluated comprised 100 patients with primary or secondary forms of coxarthrosis who underwent cementless total hip arthroplasty (THA). The results of densitometric examination of the lumbar spine and proximal femur were analysed. Based on the lowest T-score value, the patients were divided into three groups, i.e., fist, normal bone density; second, osteopenia; third, osteoporosis. Clinical examination included patient medical history, Harris hip scores and visual analogue scale assessment for pain intensity; the Kellgren-Lawrence classification was used to measure the grade of hip osteoarthritis; blood tests were made to assess the levels of total calcium, ionised calcium, phosphorus, vitamin D and the markers of bone resorption and formation. Osteoporosis was found in 32 and osteopenia in 21 patients; 47 patients had normal bone density. Osteoporosis was detected in the lumbar spine of 21 patients, in the proximal femur of nine patients and at both sites in two patients. In 13 patients this diagnosis was made for the fist time. The patients with osteoporosis had a significantly lower body mass index. There were no differences in the other characteristics, i.e., age, functional, radiological and laboratory findings, among the groups; all three showed the mean vitamin D concentration below the lowest level of its physiological range. Insufficient vitamin D levels were found in 54 women and 18 men. Of all patients, only 13 women and four men took vitamin D supplements. DISCUSSION Osteoarthritis and osteoporosis are the most frequent complex musculoskeletal diseases. Several studies have suggested that these disorders are mutually exclusive. This assumption has been based on the absence of radiographic evidence of osteoarthritis seen in many elderly patients with femoral neck fractures. Our relatively frequent findings of osteopenia and osteoporosis in this study show that patients with osteoarthritis may not be protected from the development of generalised osteoporosis. Our results are compared with the relevant literature data and potential effects of osteoporosis and vitamin D deficiency on total hip arthroplasty are discussed. Hip osteoarthritis does not reduce the risk of generalised osteoporosis. We found a relative high incidence of osteopenia and osteoporosis as well as vitamin D deficiency in patient with advanced form of hip osteoarthritis.
Lovecchio, Francis C; Manalo, John Paul; Demzik, Alysen; Sahota, Shawn; Beal, Matthew; Manning, David
2017-05-01
Avascular necrosis (AVN) may confer an increased risk of complications and readmission following total hip arthroplasty (THA). However, current risk-adjustment models do not account for AVN. A total of 1706 patients who underwent THA for AVN from 2011 to 2013 were selected from the American College of Surgeon's National Surgical Quality Improvement Program database and matched 1:1 to controls using a predetermined propensity score algorithm. Rates of 30-day medical and surgical complications, readmissions, and reoperations were compared between cohorts. Propensity-score logistic regression was used to determine independent associations between AVN and outcomes of interest. Patients with AVN had a higher rate of medical complications than those without AVN (20.3% vs 15.3%, respectively; P<.001). Bleeding transfusion was the most common medical complication, occurring at a significantly higher rate in patients with AVN than those without AVN (19.6% vs 13.9%, respectively; P<.001). Patients with AVN were also twice as likely to experience a readmission after THA (odds ratio, 2.093; 95% confidence interval, 1.385-3.164). Avascular necrosis of the femoral head is an independent risk factor for transfusion up to 72 hours postoperatively and readmission up to 30 days following total hip replacement. [Orthopedics. 2017; 40(3):171-176.]. Copyright 2017, SLACK Incorporated.
Hernigou, Philippe; Dubory, Arnaud; Homma, Yasuhiro; Guissou, Isaac; Flouzat Lachaniette, Charles Henri; Chevallier, Nathalie; Rouard, Hélène
2018-05-09
Symptomatic osteonecrosis related to corticosteroids has a high risk of progression to collapse in absence of treatment. The purposes of this study were to evaluate the results of autologous bone marrow grafting of the symptomatic hip in adult patients with osteonecrosis and to compare the results with core decompression alone in the contralateral symptomatic hip. A total of 125 consecutive patients (78 males and 47 females) with bilateral osteonecrosis (ON) and who had both hips symptomatic and at the same stage on each side (stage I or II) were included in this study from 1988 to 1998. The volume of osteonecrosis was measured with MRI in both hips; the smaller size ON was treated with core decompression, and the contralateral hip with the larger ON was treated with percutaneous mesenchymal cell (MSC) injection obtained from bone marrow concentration. The average total number of MSCs (counted as number of colony forming units-fibroblast) injected in each hip was 90,000 ± 25,000 cells (range 45,000 to 180,000 cells). At the most recent FU (average 25 years after the first surgery, range 20 to 30 years), among the 250 hips included in the study, 35 hips (28%) had collapsed at the most recent follow-up after bone marrow grafting, and 90 (72%) after core decompression (CD). Ninety-five hips (76%) in the CD group underwent total hip replacement and 30 hips (24%) in the bone marrow graft group (p < 0.0001). Hips undergoing only CD were approximately three times more likely to undergo a primary THA (odds ratio: 10.0278; 95% CI: 5.6117 to 17.9190; p < 0.0001) as compared with hips undergoing an initial bone marrow grafting. For the 90 hips treated with bone marrow injection and without collapse, the mean volume of repair evaluated by MRI at the most recent follow-up was 16.4 cm 3 (range 12 to 21 cm 3 ) corresponding to a decrease of the pre-operative average volume from 22.4 cm 3 (range 35-15 cm 3 ) to 6 cm 3 (range 12-0 cm 3 ); as percentage of the volume of the femoral head, the decrease moved from 44.8 to 12%. Core decompression with bone marrow injection improved the outcome of the disease as compared with core decompression alone in the same patient.
Well-fixed acetabular component retention or replacement: the whys and the wherefores.
Blaha, J David
2002-06-01
Occasionally the adult reconstructive surgeon is faced with a well-fixed acetabular component that is associated with an arthroplasty problem that ordinarily would require removal and replacement of the cup. Removal of a well-fixed cup is associated with considerable morbidity in bone loss, particularly in the medial wall of the acetabulum. In such a situation, retention of the cup with exchange only of the polyethylene liner may be possible. As preparation for a prospective study, I informally reviewed my experience of cup retention or replacement in revision total hip arthroplasty. An algorithm for retaining or revising a well-fixed acetabular component is presented here. Copyright 2002, Elsevier Science (USA).
Ollivier, M; Frey, S; Parratte, S; Flecher, X; Argenson, J N
2014-08-01
There is little in the literature on the level of participation in sports which patients undertake after total hip replacement (THR). Our aims in this study were to determine first, the level of sporting activity, second, the predictive factors for returning to sporting activity, and third, the correlation between participation in sports and satisfaction after THR. We retrospectively identified 815 patients who had undergone THR between 1995 and 2005. All were asked to complete a self-administered questionnaire regarding their sporting activity. A total of 571 patients (71%) met the inclusion criteria and completed the evaluation. At a mean follow-up of 9.8 years (sd 2.9), 366 patients (64%) returned to sporting activity as defined by a University of California at Los Angeles (UCLA) score of > 5. The main reasons that patients had for refraining from sports were fear of dislocation (65; 31.6%), avoiding wear (52; 25.4%), and the recommendation of the surgeon (34; 16.6%). There was a significant relationship between higher post-operative participation in sport in those patients with a higher pre-operative Harris hip score (HHS) (p = 0.0074), motivation to participate in sporting activities (p = 0.00022) and a shorter duration of symptoms (p = 0.0034). Finally, there was a correlation between age (p = 0.00013), UCLA score (p = 0.012) and pre-operative HHS (p = 0.00091) and satisfaction. In conclusion, we found that most patients participate in sporting activity after THR, regardless of the advice of their surgeon, and that there is a correlation between the level of participation and pre-operative function, motivation, duration of symptoms and post-operative satisfaction. ©2014 The British Editorial Society of Bone & Joint Surgery.
Connelly, James W; Galea, Vincent P; Laaksonen, Inari; Matuszak, Sean J; Madanat, Rami; Muratoglu, Orhun; Malchau, Henrik
2018-04-19
The purpose of this study was to identify which patient and clinical factors are predictive of adverse local tissue reaction (ALTR) and to use these factors to create a highly sensitive algorithm for indicating metal artifact reduction sequence magnetic resonance imaging (MARS-MRI) in Articular Surface Replacement (ASR) XL total hip arthroplasty patients. Our secondary aim was to compare our algorithm to existing national guidelines on when to take MARS-MRI in metal-on-metal total hip arthroplasty patients. The study consisted of 137 patients treated with unilateral ASR XL implants from a prospective, multicenter study. Patients underwent MARS-MRI regardless of clinical presentation at a mean of 6.2 (range, 3.3-10.4) years from surgery. Univariate and multivariate analyses were conducted to determine which variables were predictive of ALTR. Predictors were used to create an algorithm to indicate MARS-MRI. Finally, we compared our algorithm's ability to detect ALTR to existing guidelines. We found a visual analog scale pain score ≥2 (odds ratio [OR] = 2.53; P = .023), high blood cobalt (OR = 1.05; P = .023), and male gender (OR = 2.37; P = .034) to be significant predictors of ALTR presence in our cohort. The resultant algorithm achieved 86.4% sensitivity and 60.2% specificity in detecting ALTR within our cohort. Our algorithm had the highest area under the curve and was the only guideline that was significantly predictive of ALTR (P = .014). Our algorithm including patient-reported pain and sex-specific cutoffs for blood cobalt levels could predict ALTR and indicate MARS-MRI in our cohort of ASR XL metal-on-metal patients with high sensitivity. Level II, diagnostic study. Copyright © 2018 Elsevier Inc. All rights reserved.
Johnsen, M B; Vie, G Å; Winsvold, B S; Bjørngaard, J H; Åsvold, B O; Gabrielsen, M E; Pedersen, L M; Hellevik, A I; Langhammer, A; Furnes, O; Flugsrud, G B; Skorpen, F; Romundstad, P R; Storheim, K; Nordsletten, L; Zwart, J A
2017-06-01
Smoking has been associated with a reduced risk of hip and knee osteoarthritis (OA) and subsequent joint replacement. The aim of the present study was to assess whether the observed association is likely to be causal. 55,745 participants of a population-based cohort were genotyped for the rs1051730 C > T single-nucleotide polymorphism (SNP), a proxy for smoking quantity among smokers. A Mendelian randomization analysis was performed using rs1051730 as an instrument to evaluate the causal role of smoking on the risk of hip or knee replacement (combined as total joint replacement (TJR)). Association between rs1051730 T alleles and TJR was estimated by hazard ratios (HRs) and 95% confidence intervals (CIs). All analyses were adjusted for age and sex. Smoking quantity (no. of cigarettes) was inversely associated with TJR (HR 0.97, 95% CI 0.97-0.98). In the Mendelian randomization analysis, rs1051730 T alleles were associated with reduced risk of TJR among current smokers (HR 0.84, 95% CI 0.76-0.98, per T allele), however we found no evidence of association among former (HR 0.97, 95% CI 0.88-1.07) and never smokers (HR 0.97, 95% CI 0.89-1.06). Neither adjusting for body mass index (BMI), cardiovascular disease (CVD) nor accounting for the competing risk of mortality substantially changed the results. This study suggests that smoking may be causally associated with the reduced risk of TJR. Our findings add support to the inverse association found in previous observational studies. More research is needed to further elucidate the underlying mechanisms of this causal association. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Information for Patients Who Have Metal-on-Metal Hip Implants
... can often lead manufacturers to improve an implant’s design and update device labeling for future patients. In ... patients American Association of Hip and Knee Surgeons: Pre Op Surgery Center Patient Education: Hip Replacement Surgery ...
21 CFR 888.3340 - Hip joint metal/composite semi-constrained cemented prosthesis.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/composite semi-constrained... Hip joint metal/composite semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/composite semi-constrained cemented prosthesis is a two-part device intended to be implanted to replace a...
Incidence and Risk Factors for Health-Care Associated Infections after Hip Operation.
Hessels, Amanda J; Agarwal, Mansi; Liu, Jianfang; Larson, Elaine L
2016-12-01
Hip operation reduces pain and improves mobility and quality of life for more than 300,000 people annually, most of whom are more than 65 years old. Substantial increases in surgical volume are projected between 2005 and 2030 in primary total (174%) and revision (137%) procedures. This projection demands that the impact of increasing age on the relative risk of health-care associated infections (HAI) after hip surgical procedures be assessed. Our aim was to examine the incidence and risk factors of HAI among patients who underwent hip operations between 2006 and 2012. This secondary analysis included data from patients 18 years old or older and having a hip prosthesis procedure in three New York City hospitals between 2006 and 2012. Procedures were categorized as total or partial hip replacements or revision and re-surfacing procedures. Outcomes of interest were blood stream infections (BSI), urinary tract infections (UTI), or surgical site infections (SSI). Patients in whom an infection developed during the hospital visit in which the hip procedure occurred were counted as cases. Of 2021 patients, approximately 11% (n = 218) had an HAI. There was no difference in infection rates by admission year despite an increase in surgical volume. SSI was associated with younger age, previous hospitalization, and hip revision surgical procedure whereas UTI and BSI were associated with older age, greater co-morbidity, longer pre-operative length of stay and intensive care unit stay, (p < 0.05). HAI after hip operation affected approximately one in 10 patients over a 7-year period in three high-volume hospitals. SSI occurred least frequently, predominantly among patients who underwent revision surgery (without previous SSI), were younger, and had a history of previous hospitalization. Infections such as BSI and UTI, although rare, occurred more frequently and in patients with more co-morbidities, longer pre-operative length of stay, and who required higher level care. Further research to understand these unexpected findings and target interventions is warranted.
Risk factors for perioperative hyperglycemia in primary hip and knee replacements
Jämsen, Esa; Nevalainen, Pasi I; Eskelinen, Antti; Kalliovalkama, Jarkko; Moilanen, Teemu
2015-01-01
Background and purpose Background and purpose — Perioperative hyperglycemia has been associated with adverse outcomes in several fields of surgery. In this observational study, we identified factors associated with an increased risk of hyperglycemia following hip and knee replacement. Patients and methods Patients and methods — We prospectively monitored changes in glucose following primary hip and knee replacements in 191 patients with osteoarthritis. Possible associations of patient characteristics and operation-related factors with hyperglycemia (defined as glucose > 7.8 mmol/L in 2 consecutive measurements) and severe hyperglycemia (glucose > 10 mmol/L) were analyzed using binary logistic regression with adjustment for age, sex, operated joint, and anesthesiological risk score. Results Results — 76 patients (40%) developed hyperglycemia, and 48 of them (25% of the whole cohort) had severe hyperglycemia. Glycemic responses were similar following hip replacement and knee replacement. Previously diagnosed diabetes was associated with an increased risk of hyperglycemia and severe hyperglycemia, compared to patients with normal glucose metabolism, whereas newly diagnosed diabetes and milder glucose metabolism disorders had no effect. In patients without previously diagnosed diabetes, increased values of preoperative glycosylated hemoglobin (HbA1c) and fasting glucose on the day of operation were associated with hyperglycemia. Higher anesthesiological risk score—but none of the operation-related factors analyzed—was associated with an increased risk of hyperglycemia. Interpretation Interpretation — Perioperative hyperglycemia is common in primary hip and knee replacements. Previously diagnosed diabetes is the strongest risk factor for hyperglycemia. In patients with no history of diabetes, preoperative HbA1c and fasting glucose on the day of operation can be used to stratify the risk of hyperglycemia. PMID:25409255
Koudela, K; Koudelová, J; Koudela, K; Kunesová, M
2008-10-01
PURPOSE OF THE STUDY To present clinical and radiographic findings of iliopectineal bursitis and draw attention to some related etiopathogenetic factors. MATERIAL AND METHODS Six patients followed up between 2005 and 2007 were evaluated. They included four women and two men (average age, 58 years; range, 35 to 80 years) who presented with a tender mass in the hip region (four right and two left sides). Each patient underwent an examination involving a clinical check-up, imaging methods (CT, MR, angio-CT) and standard laboratory tests. RESULTS Iliopectineal bursitis clinically manifested as a tender mass in the groin and hip region in five patients; in one it was pulsating. The sixth case was asymptomatic. In three patients iliopectineal bursitis was found in association with steroid therapy and subsequent avascular necrosis of the femoral head and chronic synovitis. It followed tularemia with hip joint involvement in one patient, salmonella arthritis in one, and kidney transplant rejection in one. Also, iliopectineal bursitis was diagnosed in a patient with rheumatoid arthritis treated with steroids, but without femoral head avascular necrosis, and was incidentally found in another patient examined for digestive problems. Of the six cases of swollen bursa detected by the imaging methods used, five were found to communicate with the hip joint cavity, with four being so large that the bursa extended into the retroperitoneum. Two patients underwent excision or resection of the bursa; in addition, one of them had revitalizing graft surgery for femoral head necrosis. The patient with salmonella arthritis had to undergo a Girdlestone procedure. One patient was treated by draining of the bursa and, after inflammation resolved, total hip replacement surgery was carried out during which the iliopectineal bursa was removed. The patient with rheumatoid arthritis was treated by bursa draining and refused further surgical therapy (total hip replacement). DISCUSSION In our group of six patients, bursitis was symptomatic in five and was associated with chronic hip synovitis accompanying femoral head necrosis following steroid therapy or inflamation, either non-specific or arthitic. Bursitis was asymptomatic in one patient and was diagnosed only incidentally on CT examination done for another reason. The communication between the bursa and the hip joint cavity, found on CT scans and magnetic resonance images, was a radiographic factor important for differential diagnosis. The underlying disease of the hip joint plays a key role in the etiopathogenesis of iliopectineal bursitis. Therefore, surgical treatment should be comprehensible and, in addition to bursa resection or excision, should also include treatment of the affected joint (alloplasty, femoral head resection or revitalization). CONCLUSION Iliopectineal bursitis is associated with chronic hip synovitis present in degenerative, infectious or rheumatic joint diseases. When a lump is diagnosed in the inguinal or hip region, iliopectineal bursitis should always be considered in addition to conditions such as abscess, cyst, hernia, pseudoaneurysm, lymphocele, etc. The finding of communication beteen the bursa and hip joint cavity, made on CT scans or magnetic resonance images, is a radiographic factor important in terms of differential diagnosis. The surgical treatment of iliopectineal bursitis includes excision or resection of the bursa and therapy for the hip joint (alloplasty, femoral head resection or revitalization).
Clinical Biomechanics of Wear in Total Hip Arthroplasty
Callaghan, John J; Pedersen, Douglas R; Johnston, Richard C; Brown, Thomas D
2003-01-01
Complementary clinical and laboratory studies were performed to identify variables associated with polyethylene wear following total hip replacement, and to elucidate the mechanisms responsible for accelerated wear in the total hip arthroplasty construct. Observational cohort studies were performed using a prospective clinical database of more than 4000 consecutive primary total hip arthroplasties performed by a single surgeon, to identify wear-related variables. These variables included head size, acetabular/femoral component impingement, and third body debris. Novel digital edge detection techniques were developed and employed to accurately measure wear, and to determine the relationships of head size and third body debris to acceleration of wear. A novel slidingdistance-coupled finite element model was formulated and employed to examine the mechanisms responsible for wear. The long-term cohort studies demonstrated smaller head sizes to be associated with less wear. Third body debris generated from cable fretting was associated with an increase in wear, osteolysis, and acetabular loosening, especially with larger head sizes. The sliding-distance-coupled finite element model replicated the wear rates occurring in vitro and in vivo, demonstrating the importance of sliding distance on polyethylene wear following total hip arthroplasty. It also demonstrated substantial increases in wear associated with femoral head scratching from third body debris. Further extension of the finite element formulation demonstrated the potential for acetabular component rim damage from impingement wear, and the enhanced potential for third body ingress to the bearing surface with larger head sizes. Edge detection wear measurement techniques demonstrated that early wear rates were predictive of long-term wear rates. These complementary clinical and laboratory investigations have provided insight into 1) the significance of sliding distance and physiologic loci of motion as contributing factors in minimizing wear, 2) the deleterious effects of third body particulates in accelerating wear, 3) the potential for, and factors related to, impingement wear, and 4) the potential advantages and compromises related to the use of larger head sizes in the bearing surface construct. PMID:14575243
Finite element analysis on a medical implant.
Semenescu, Augustin; Radu-Ioniță, Florentina; Mateș, Ileana Mariana; Bădică, Petre; Batalu, Nicolae Dan; Negoita, Olivia Doina; Purcarea, Victor Lorin
2016-01-01
Several studies have shown a tight connection between several ocular pathologies and an increased risk of hip fractures due to falling, especially among elderly patients. The total replacement of the hip joint is a major surgical intervention that aims to restore the function of the affected hip by various factors, such as arthritis, injures, and others. A corkscrew-like femoral stem was designed in order to preserve the bone stock and to prevent the occurrence of iatrogenic fractures during the hammering of the implant. In this paper, the finite element analysis for the proposed design was applied, considering different loads and three types of materials. A finite element analysis is a powerful tool to simulate, optimize, design, and select suitable materials for new medical implants. The results showed that the best scenario was for Ti6Al4V alloy, although Ti and 316L stainless steel had a reasonable high safety factor.
Brennan-Olsen, Sharon; Vogrin, Sara; Holloway, Kara L; Page, Richard S; Sajjad, Muhammad A; Kotowicz, Mark A; Livingston, Patricia M; Khasraw, Mustafa; Hakkennes, Sharon; Dunning, Trish L; Brumby, Susan; Pedler, Daryl; Sutherland, Alasdair; Venkatesh, Svetha; Williams, Lana J; Duque, Gustavo; Pasco, Julie A
2017-11-06
Compared to urban residents, those in rural/regional areas often experience inequitable healthcare from specialist service providers. Independent of small between-area differences in utilisation, socially advantaged groups had the greatest uptake of joint replacement. These data suggest low correlation between 'need' vs. 'uptake' of surgery in rural/regional areas. Compared to urban residents, those in rural and regional areas often experience inequitable healthcare from specialist service providers, often due to geographical issues. We investigated associations between socioeconomic position (SEP), region of residence and utilisation of primary total knee replacement (TKR) and/or total hip replacement (THR) for osteoarthritis. As part of the Ageing, Chronic Disease and Injury study, we extracted data from the Australian Orthopaedic Association National Joint Replacement Registry (2011-2013) for adults that utilised primary TKR (n = 4179; 56% female) and/or THR (n = 3120; 54% female). Residential addresses were matched with the Australian Bureau of Statistics (ABS) 2011 census data: region of residence was defined according to local government areas (LGAs), and area-level SEP (quintiles) defined using an ABS-derived composite index. The ABS-determined control population (n = 591,265; 51% female) excluded individuals identified as cases. We performed multilevel logistic regression modelling using a stratified two-stage cluster design. TKR was higher for those aged 70-79 years (AOR 1.4 95%CI 1.3-1.5; referent = 60-69 years) and in the most advantaged SEP quintile (AOR 2.1, 95%CI 1.8-2.3; referent = SEP quintile 3); results were similar for THR (70-79 years = AOR 1.7, 95%CI 1.5-1.8; SEP quintile 5 = AOR 2.5, 95%CI 2.2-2.8). Total variances contributed by the variance in LGAs were 2% (SD random effects ± 0.28) and 3% (SD ± 0.32), respectively. Independent of small between-LGA differences in utilisation, and in contrast to the expected greater prevalence of osteoarthritis in disadvantaged populations, we report greater TKR and THR in more advantaged groups. Further research should investigate whether more advantaged populations may be over-serviced.
Rozell, Joshua C; Courtney, Paul M; Dattilo, Jonathan R; Wu, Chia H; Lee, Gwo-Chin
2016-09-01
Alternative payment models in total joint replacement incentivize cost effective health care delivery and reward reductions in length of stay (LOS), complications, and readmissions. If not adjusted for patient comorbidities, they may encourage restrictive access to health care. We prospectively evaluated 802 consecutive primary total hip arthroplasty and total knee arthroplasty patients evaluating comorbidities associated with increased LOS and readmissions. During this 9-month period, 115 patients (14.3%) required hospitalization >3 days and 16 (1.99%) were readmitted within 90 days. Univariate analysis demonstrated that preoperative narcotic use, heart failure, stroke, chronic kidney disease (CKD), chronic obstructive pulmonary disease (COPD), and liver disease were more likely to require hospitalization >3 days. In multivariate analysis, CKD and COPD were independent risk factors for LOS >3 days. A Charlson comorbidity index >5 points was associated with increased LOS and readmissions. Patients with CKD, COPD, and Charlson comorbidity index >5 points should not be included in alternative payment model for THA and TKA. Copyright © 2016 Elsevier Inc. All rights reserved.
Rampazo-Lacativa, Mariana Kátia; Santos, Ariene Angelini dos; Coimbra, Arlete Maria Valente; D'Elboux, Maria José
2015-01-01
Quality-of-life results have increasingly been evaluated among patients undergoing joint replacements. The objective of this study was to compare two assessment instruments for health-related quality of life (one generic and the other specific), among elderly patients undergoing total hip arthroplasty. Cross-sectional descriptive study in a reference hospital in the region of Campinas. The subjects were 88 elderly outpatients aged 60 years or over who underwent primary total hip arthroplasty. Two instruments for assessing health-related quality of life were applied: the generic Medical Study 36-item Short-Form Health Survey (SF-36) and the specific Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Cronbach's alpha and the ceiling and floor effects of the instruments were evaluated. The scores from both instruments showed that issues of a physical nature affected these elderly people's quality of life most. The pain and stiffness dimensions of WOMAC showed ceiling effects and only the functional capacity and pain dimensions of the SF-36 did not show the ceiling effect. The SF-36 presented floor effects in the dimensions of physical and emotional aspects. Cronbach's alpha was considered satisfactory in both instruments (α > 0.70). The floor and ceiling effects that were observed suggest that these instruments may present some limitations in detecting changes to the majority of the SF-36 dimensions, except for functional capacity and pain, and to the pain and stiffness dimensions of WOMAC, when applied to elderly people with total hip arthroplasty.
Parchi, Paolo Domenico; Ferrari, Vincenzo; Piolanti, Nicola; Andreani, Lorenzo; Condino, Sara; Evangelisti, Gisberto; Lisanti, Michele
2013-09-01
Each year approximately 1 million total hip replacements (THR) are performed worldwide. A percentage of failure due to surgical approach and imprecise implant placement still exists. These result in several serious complications. We propose an approach to plan, to simulate, and to assist prosthesis implantation for difficult cases of THR based on 3-D virtual models, generated by segmenting patients' CT images, 3-D solid models, obtained by rapid prototyping (RP), and virtual procedure simulation. We carried out 8 THR with the aid of 3-D reconstruction and RP. After each procedure a questionnaire was submitted to the surgeon to assess the perceived added value of the technology. In all cases, the surgeon evaluated the 3-D model as useful in order to perform the planning. The clinical results showed a mean increase in the Harris Hip Score of about 42.5 points. The mean time of prototyping was 7.3 hours, (min 3.5 hours, max 9.3 hours). The mean surgery time was 65 minutes (min 50 minutes, max 88 minutes). Our study suggests that meticulous preoperative planning is necessary in front of a great aberration of the joint and in absence of normal anatomical landmarks, CT scan is mandatory, and 3-D reconstruction with solid model is useful.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Siegel, R.S.; Rae, J.L.; Ryan, N.L.
Five hundred indium-111 labeled platelet imaging studies (387 donor and 113 autologous) were performed postoperatively in 473 patients who had undergone total hip replacement, total knee replacement, or internal fixation of a hip fracture to detect occult deep venous thrombosis. All patients had been anticoagulated prophylactically with aspirin, warfarin sodium (Coumadin), or dextran. Thirty-four possible cases of proximal deep venous thrombosis were identified in 28 asymptomatic patients. To verify the scan results, 31 venograms were performed in 25 patients (three refused). In 21 of 31 cases, totally occlusive thrombi were detected; in 5 cases, partially occlusive thrombi were detected; inmore » 5 cases, no thrombus was seen. No patient who had a negative scan nor any patient who had a verified positive scan (and received appropriate heparin therapy) subsequently developed symptoms or signs of pulmonary embolism. One hundred forty-one indium study patients also underwent Doppler ultrasonography/impedance plethysmography (Doppler/IPG) as a comparative non-invasive technique. In 137 cases, the results of the indium study and Doppler/IPG studies were congruent. The indium study had no false negative results that were detected by Doppler/IPG. No patient had any clinically evident toxicity. These results suggest that indium-111 labeled platelet scanning is a safe, noninvasive means for identifying DVT in high risk patients.« less
Ruggiero, Alessandro; Merola, Massimiliano; Affatato, Saverio
2018-04-09
The hip joint replacement is one of the most successful orthopedic surgical procedures although it involves challenges to overcome. The patient group undergoing total hip arthroplasty now includes younger and more active patients who require a broad range of motion and a longer service lifetime for the replacement joint. It is well known that wear tests have a long duration and they are very expensive, thus studying the effects of geometry, loading, or alignment perturbations may be performed by Finite Element Analysis. The aim of the study was to evaluate total deformation and stress intensity on ultra-high molecular weight polyethylene liner coupled with hard material head during one step. Moving toward in-silico wear assessment of implants, in the presented simulations we used a musculoskeletal multibody model of a human body giving the loading and relative kinematic of the investigated tribo-system during the gait. The analysis compared two frictional conditions -dry and wet and two geometrical cases- with and without radial clearance. The loads and rotations followed the variability of the gait cycle as well as stress/strain acting in the UHWMPE cup. The obtained results allowed collection of the complete stress/strain description of the polyethylene cup during the gait and calculation of the maximum contact pressure on the lateral edge of the insert. The tensional state resulted in being more influenced by the geometrical conditions in terms of radial clearance than by the variation of the friction coefficients due to lubrication phenomena.
Audit on the Efficient Use of Cross-Matched Blood in Elective Total Hip and Total Knee Replacement
Rogers, BA; Johnstone, DJ
2006-01-01
INTRODUCTION This prospective audit studies the use of cross-matched blood in 301 patients over a 1-year period undergoing total knee (TKR) and total hip replacement (THR) surgery in an orthopaedic unit. PATIENTS AND METHODS Analysis over the first 6 months revealed a high level of unnecessary cross-matched blood. The following interventions were introduced: (i) to cease routine cross-matching for THR; (ii) all patients to have a check full blood count on day 2 after surgery; and (iii) Hb < 8 g/dl to be considered as the trigger for transfusion in patients over 65 years and free from significant co-morbidity. These changes are in accordance with published national guidelines [Anon. Guidelines for the clinical use of red cell transfusions. Br J Haematol 2001; 113: 24–31]. RESULTS In the next 6 months, the number of units cross-matched but not transfused fell by 96% for THR, and the cross-match transfusion (C:T) ratio reduced from 3.21 to 1.62. Reductions were also observed for the TKR cohort. These results provide evidence of a substantial risk and cost benefit in the use of this limited resource. A telephone survey of 44 hospitals revealed that 20 hospitals routinely cross-matched blood for THR and 11 do so for TKR. CONCLUSIONS Changes can be made to the Maximum Surgical Blood Ordering Schedules (MSBOS) in other orthopaedic units according to national guidelines. PMID:16551419
Pedersen, A B; Mehnert, F; Sorensen, H T; Emmeluth, C; Overgaard, S; Johnsen, S P
2014-04-01
We examined the risk of thrombotic and major bleeding events in patients undergoing total hip and knee replacement (THR and TKR) treated with thromboprophylaxis, using nationwide population-based databases. We identified 83 756 primary procedures performed between 1997 and 2011. The outcomes were symptomatic venous thromboembolism (VTE), myocardial infarction (MI), stroke, death and major bleeding requiring hospitalisation within 90 days of surgery. A total of 1114 (1.3%) and 483 (0.6%) patients experienced VTE and bleeding, respectively. The annual risk of VTE varied between 0.9% and 1.6%, and of bleeding between 0.4% and 0.8%. The risk of VTE and bleeding was unchanged over a 15-year period. A total of 0.7% of patients died within 90 days, with a decrease from 1% in 1997 to 0.6% in 2011 (p < 0.001). A high level of comorbidity and general anaesthesia were strong risk factors for both VTE and bleeding, with no difference between THR and TKR patients. The risk of both MI and stroke was 0.5%, which remained unchanged during the study period. In this cohort study of patients undergoing THR and TKR patients in routine clinical practice, approximately 3% experienced VTE, MI, stroke or bleeding. These risks did not decline during the 15-year study period, but the risk of dying fell substantially.
Hartmann, Albrecht; Hannemann, Franziska; Lützner, Jörg; Seidler, Andreas; Drexler, Hans; Günther, Klaus-Peter; Schmitt, Jochen
2013-01-01
Introduction The use of metal-on-metal (MoM) total hip arthroplasty (THA) increased in the last decades. A release of metal products (i.e. particles, ions, metallo-organic compounds) in these implants may cause local and/or systemic adverse reactions. Metal ion concentrations in body fluids are surrogate measures of metal exposure. Objective To systematically summarize and critically appraise published studies concerning metal ion concentrations after MoM THA. Methods Systematic review of clinical trials (RCTs) and epidemiological studies with assessment of metal ion levels (cobalt, chromium, titanium, nickel, molybdenum) in body fluids after implantation of metalliferous hip replacements. Systematic search in PubMed and Embase in January 2012 supplemented by hand search. Standardized abstraction of pre- and postoperative metal ion concentrations stratified by type of bearing (primary explanatory factor), patient characteristics as well as study quality characteristics (secondary explanatory factors). Results Overall, 104 studies (11 RCTs, 93 epidemiological studies) totaling 9.957 patients with measurement of metal ions in body fluids were identified and analyzed. Consistently, median metal ion concentrations were persistently elevated after implantation of MoM-bearings in all investigated mediums (whole blood, serum, plasma, erythrocytes, urine) irrespective of patient characteristics and study characteristics. In several studies very high serum cobalt concentrations above 50 µg/L were measured (detection limit typically 0.3 µg/L). Highest metal ion concentrations were observed after treatment with stemmed large-head MoM-implants and hip resurfacing arthroplasty. Discussion Due to the risk of local and systemic accumulation of metallic products after treatment with MoM-bearing, risk and benefits should be carefully balanced preoperatively. The authors support a proposed „time out“ for stemmed large-head MoM-THA and recommend a restricted indication for hip resurfacing arthroplasty. Patients with implanted MoM-bearing should receive regular and standardized monitoring of metal ion concentrations. Further research is indicated especially with regard to potential systemic reactions due to accumulation of metal products. PMID:23950923
Dieppe, Paul; Judge, Andrew; Williams, Susan; Ikwueke, Ifeoma; Guenther, Klaus-Peter; Floeren, Markus; Huber, Joerg; Ingvarsson, Thorvaldur; Learmonth, Ian; Lohmander, L Stefan; Nilsdotter, Anna; Puhl, Wofhart; Rowley, David; Thieler, Robert; Dreinhoefer, Karsten
2009-01-01
Background Total hip joint replacement (THR) is a high volume, effective intervention for hip osteoarthritis (OA). However, indications and determinants of outcome remain unclear. The 'EUROHIP consortium' has undertaken a cohort study to investigate these questions. This paper describes the variations in disease severity in this cohort and the relationships between clinical and radiographic severity, and explores some of the determinants of variation. Methods A minimum of 50 consecutive, consenting patients coming to primary THR for primary hip OA in each of the 20 participating orthopaedic centres entered the study. Pre-operative data included demographics, employment and educational attainment, drug utilisation, and involvement of other joints. Each subject completed the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC – Likert version 3.1). Other data collected at the time of surgery included the prosthesis used and American Society of Anaesthesiologists (ASA) status. Pre-operative radiographs were read by the same three readers for Kellgren and Lawrence (K&L) grading and Osteoarthritis Research Society International (OARSI) atlas features. Regression analyses were carried out. Results Data from 1327 subjects has been analysed. The mean age of the group was 65.7 years, and there were more women (53.4%) than men. Most (79%) were ASA status 1 or 2. Reported disease duration was 5 years or less in 69.2%. Disease in other joint sites was common. Radiographs were available in 1051 subjects and the K&L grade was 3 or 4 in 95.8%. There was much more variation in clinical severity (WOMAC score); the mean total WOMAC score was 59.2 (SD 16.1). The radiographic severity showed no correlation with WOMAC scores. Significantly higher WOMAC scores (worse disease) were seen in older people, women, those with obesity, those with worse general health, and those with lower educational attainment. Conclusion 1. Clinical disease severity varies widely at the time of THR for OA. 2. In advanced hip OA clinical severity shows no correlation with radiographic severity. 3. Simple scores of pain and disability do not reflect the complexity of decision-making about who should have a THR. PMID:19208230
Patient survival and surgical re-intervention predictors for intracapsular hip fractures.
González Quevedo, David; Mariño, Iskandar Tamimi; Sánchez Siles, Juan Manuel; Escribano, Esther Romero; Granero Molina, Esther Judith; Enrique, David Bautista; Smoljanović, Tomislav; Pareja, Francisco Villanueva
2017-08-01
Choosing between total hip replacement (THR) and partial hip replacement (PHR) for patients with intracapsular hip fractures is often based on subjective factors. Predicting the survival of these patients and risk of surgical re-intervention is essential to select the most adequate implant. We conducted a retrospective cohort study on mortality of patients over 70 years with intracapsular hip fractures who were treated between January 2010 and December 2013, with either PHR or THR. Patients' information was withdrawn from our local computerized database. The age-adjusted Charlson comorbidity index (ACCI) and American Society of Anesthesiologists (ASA) score were calculated for all patients. The patients were followed for 2 years after surgery. Survival and surgical re-intervention rates were compared between the two groups using a Multivariate Cox proportional hazard model. A total of 356 individuals were included in this study. At 2 years of follow-up, 221 (74.4%) of the patients with ACCI score≤7 were still alive, in contrast to only 20 (29.0%) of those with ACCI score>7. In addition, 201 (76.2%) of the patients with ASA score≤3 were still alive after 2 years, compared to 30 (32.6%) of individuals with ASA >3. Patients with the ACCI score>7, and ASA score>3 had a significant increase in all-cause 2-year mortality (adjusted hazard ratio of 3.2, 95% CI 2.2-4.6; and 3.12, 95% CI 2.2-4.5, respectively). Patients with an ASA score>3 had a quasi-significant increase in the re-intervention risk (adjusted hazard ratio 2.2, 95% CI 1.0-5.1). The sensitivity, specificity, positive predictive value and negative predictive values of ACCI in predicting 2-year mortality were 39.2%, 91.1%, 71%, and 74.4%, respectively. On the other hand, the sensitivity, specificity, positive predictive value and negative predictive values of ASA score in predicting 2-year mortality were 49.6%, 79.1%, 67.4%, and 76.1%, respectively. Both ACCI and ASA scales were able to predict the 2-year survival of patients with intracapsular hip fractures. The ASA scale was also able to predict the risk of re-intervention in these patients. Copyright © 2017 Elsevier Ltd. All rights reserved.
Elevated levels of numerous cytokines in drainage fluid after primary total hip arthroplasty.
van der Heide, Huub J L; van der Kraan, Peter M; Rijnberg, Willard J; Buma, Pieter; Schreurs, B Willem
2010-12-01
As cytokines are involved in wound healing and other inflammatory processes, it could be valuable to measure their levels at the operative site. This study was conducted to investigate whether different cytokines are measurable in drainage fluid and, when measurable, whether we can find a difference in cytokine levels between one and six hours postoperatively. Samples from the drainage system in 30 consecutive patients undergoing primary total hip replacement were collected at one and six hours after closure of the wound. Levels of several cytokines were measured in the drainage fluids. A significant elevation of almost all cytokines was observed between the sample after one hour and six hours postoperatively. We found a strong correlation between the different pro-inflammatory cytokines. The IL-6 to IL-10 ratio were also raised, showing a pro-inflammatory predominance. Levels were much higher than those previously shown in serum.
Crumley Aybar, Bonnie L; Gillespie, Michael J; Gipson, Sean F; Mullaney, Caitlin E; Tommasino-Storz, Melissa
2016-12-01
A systematic review of the literature was completed by the Evidence-Based Practice Group for the Patient population, Intervention/Issue, Comparison Intervention, Outcomes, Timing (PICOT) question: "Does the use of a peripheral nerve block increase the risk for falls and difficulty ambulation in patients after lower extremity surgery through postoperative day 2?" A search of multiple databases using specified key terms resulted in 258 articles for total knee arthroplasty or total hip arthroplasty. These were reduced to 13 with exclusion criteria and became primary evidence. Numbers Needed to Harm and Numbers Needed to Treat (NNT) were calculated. Numbers Needed to Harm supported the PICOT question. Further research of postoperative falls and nursing interventions to reduce or prevent falls is suggested before creation of a Clinical Practice Guideline. Copyright © 2016 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.
Christopher, Scott A; Kim, Stanley E; Roe, Simon; Pozzi, Antonio
2016-08-01
Periprosthetic femoral fractures are a common complication associated with cementless press-fit total hip arthroplasty. The use of prophylactic cerclage wire fixation has been advocated to reduce this complication. The objective of this study was to evaluate whether a double loop cerclage wire, used as adjunctive fixation, increased the peak torsional load to failure in femora implanted with press-fit cementless stems. Peak torsional load to failure was compared between femora without adjunctive fixation and femora receiving a 1 mm double loop cerclage wire placed proximally to the lesser trochanter. Femora treated with adjunctive cerclage wire fixation failed at 20% greater peak torque (P = 0.0001). In conclusion, a double loop cerclage wire may aid in the prevention of periprosthetic fractures associated with press-fit cementless femoral stems. Copyright © 2016. Published by Elsevier Ltd.
Hip arthroplasty today and tomorrow.
Amstutz, H C
1987-12-01
Acrylic-fixed total hip and surface replacement arthroplasty have been very effective in affording immediate relief of pain and providing improved function. Complications have been reduced by improvements in design, materials, and especially technique. They are now very low in the elderly, and the stem type acrylic-fixed design remains the procedure of choice. The failure rates in youthful patients and those with bone-stock deficiencies have been high in both THR and surface types, although the latter had the advantage of preserving femoral stock. On the femoral side, the new "macro" femoral designs from Europe and "micro" femoral porous designs have shown promise, but thigh pain, incomplete and difficult to predict bone ingrowth patterns, coupled with removal problems have influenced design and technique changes. Both press-fit stem types and porous surface replacements have produced promising initial results with less potential downside risks. On the acetabular side, both the cementless hemispherical with screw-type adjuvant fixation, or the chamfered cylinder designs, used primarily with the UCLA porous surface replacements, but also with stem-type devices, appear to achieve best short-term results, while the entire variety of screw rings are disappointing. The future will bring further refinements in technique and specific indications for certain types of replacement stem in specific types of bone stock deficiencies. The all ceramic-ceramic and ceramic-polyethylene bearings show promise of reducing wear and, hence, should improve longevity of implant fixation.
Duncan, Christopher M; Hall Long, Kirsten; Warner, David O; Hebl, James R
2009-01-01
Total knee and total hip arthoplasty (THA) are 2 of the most common surgical procedures performed in the United States and represent the greatest single Medicare procedural expenditure. This study was designed to evaluate the economic impact of implementing a multimodal analgesic regimen (Total Joint Regional Anesthesia [TJRA] Clinical Pathway) on the estimated direct medical costs of patients undergoing lower extremity joint replacement surgery. An economic cost comparison was performed on Mayo Clinic patients (n = 100) undergoing traditional total knee or total hip arthroplasty using the TJRA Clinical Pathway. Study patients were matched 1:1 with historical controls undergoing similar procedures using traditional anesthetic (non-TJRA) techniques. Matching criteria included age, sex, surgeon, type of procedure, and American Society of Anesthesiologists (ASA) physical status (PS) classification. Hospital-based direct costs were collected for each patient and analyzed in standardized inflation-adjusted constant dollars using cost-to-charge ratios, wage indexes, and physician services valued using Medicare reimbursement rates. The estimated mean direct hospital costs were compared between groups, and a subgroup analysis was performed based on ASA PS classification. The estimated mean direct hospital costs were significantly reduced among TJRA patients when compared with controls (cost difference, 1999 dollars; 95% confidence interval, 584-3231 dollars; P = 0.0004). A significant reduction in hospital-based (Medicare Part A) costs accounted for the majority of the total cost savings. Use of a comprehensive, multimodal analgesic regimen (TJRA Clinical Pathway) in patients undergoing lower extremity joint replacement surgery provides a significant reduction in the estimated total direct medical costs. The reduction in mean cost is primarily associated with lower hospital-based (Medicare Part A) costs, with the greatest overall cost difference appearing among patients with significant comorbidities (ASA PS III-IV patients).
Outcomes of a metal-on-metal total hip replacement system.
Matharu, G S; Theivendran, K; Pynsent, P B; Jeys, L; Pearson, A M; Dunlop, D J
2014-10-01
High short-term failure rates have been reported for a variety of metal-on-metal (MoM) total hip replacements (THRs) owing to adverse reactions to metal debris (ARMD). This has led to the withdrawal of certain poorly performing THRs. This study analysed the outcomes of a MoM THR system. Between 2004 and 2010, 578 uncemented MoM THRs (511 patients, mean age: 60.0 years) were implanted at one specialist centre. The THR system used consisted of the Corail(®) stem, Pinnacle(®) cup, Ultamet(®) liner and Articul/eze(®) femoral head (all DePuy, Leeds, UK). All patients were recalled for clinical review with imaging performed as necessary. The mean follow-up duration was 5.0 years (range: 1.0-9.1 years). Overall, 39 hips (6.7%) in 38 patients (all 36 mm femoral head size) underwent revision at a mean time of 3.5 years (range: 0.01-8.3 years) from the index THR with 30 revisions (77%) performed in women. The cumulative eight-year survival rate for all THRs was 88.9% (95% confidence interval [CI]: 78.5-93.4%), with no difference (p=0.053) between male (95.2%, 95% CI: 84.2-98.7%) and female patients (85.3%, 95% CI: 70.2-92.1%) at eight years. Seventeen revisions (44%) were performed for ARMD. There was no significant difference in absolute postoperative Oxford hip scores between men and women (p=0.608). The mean acetabular inclination in unrevised THRs was 44.0°. Forty-seven non-revised THRs (8.7%) had blood metal ion concentrations above recommended thresholds (seven had periprosthetic effusions). Although this MoM THR system has not failed as dramatically as other similar designs, we recommend against continued use and advise regular clinical surveillance to identify ARMD early.
Messori, Andrea; Trippoli, Sabrina; Marinai, Claudio
2017-01-01
Objectives In most European countries, innovative medical devices are not managed according to cost–utility methods, the reason being that national agencies do not generally evaluate these products. The objective of our study was to investigate the cost-utility profile of prostheses for hip replacement and to calculate a value-based score to be used in the process of procurement and tendering for these devices. Methods The first phase of our study was aimed at retrieving the studies reporting the values of QALYs, direct cost, and net monetary benefit (NMB) from patients undergoing total hip arthroplasty (THA) with different brands of hip prosthesis. The second phase was aimed at calculating, on the basis of the results of cost–utility analysis, a tender score for each device (defined according to standard tendering equations and adapted to a 0–100 scale). This allowed us to determine the ranking of each device in the simulated tender. Results We identified a single study as the source of information for our analysis. Nine device brands (cemented, cementless, or hybrid) were evaluated. The cemented prosthesis Exeter V40/Elite Plus Ogee, the cementless device Taperloc/Exceed, and the hybrid device Exeter V40/Trident had the highest NMB (£152 877, £156 356, and £156 210, respectively) and the best value-based tender score. Conclusions The incorporation of value-based criteria in the procurement process can contribute to optimising the value for money for THA devices. According to the approach described herein, the acquisition of these devices does not necessarily converge on the product with the lowest cost; in fact, more costly devices should be preferred when their increased cost is offset by the monetary value of the increased clinical benefit. PMID:29259062
Outcomes of total hip arthroplasty: a study of patients one year postsurgery.
Trudelle-Jackson, Elaine; Emerson, Roger; Smith, Sue
2002-06-01
Ex post facto research using prospective analysis of differences between the involved hip and uninvolved hip. To assess outcomes of total hip arthroplasty (THA) by comparing range of motion (ROM), muscle strength, and postural stability in the surgical hip to those of the uninvolved hip 1 year postsurgery. An additional objective was to assess degree of relationship among ROM, strength, and postural stability impairments to a measure of self-assessed function. Most patients who have THA receive physical therapy that consists mainly of self-care instructions and an exercise protocol that emphasizes mobility during the acute phase of recovery. But, outcomes of THA 1 year postsurgery indicate that current physical therapy programs used during the acute phase of recovery do not effectively restore physical and functional performance. Subjects consisted of 11 women and 4 men (mean age +/- standard deviation = 62 +/- 8 years) with unilateral THA performed 1 year prior to data collection. Assessment variables consisted of self-assessment of function and measures of postural stability, muscle strength, and hip ROM. The 12-Item Hip Questionnaire was used for self-assessment of function. Three separate repeated measures MANOVA were used to compare the involved side to the uninvolved side in measures of postural stability, strength, and ROM. The Spearman's rho was used to assess degree of association between the subjects' score of self-assessed function and impairments in strength and postural stability. Measures of postural stability were significantly lower (P < or = 0.01) on the side of the replaced hip. Differences in strength values between the involved and uninvolved sides were not statistically significant. Correlations between scores of self-assessed function and hip abductor and knee extensor strength were statistically significant (r = 0.56, P < or = 0.03). Self-assessed function was not significantly correlated to postural stability impairments. The brief postsurgical rehabilitation program received by patients with THA may not be sufficient. A second phase of rehabilitation implemented 4 months or more after surgery that emphasizes weight bearing and postural stability may be advisable.
Geiger, A J; Ward, S H; Williams, C C; Rude, B J; Cabrera, C J; Kalestch, K N; Voelz, B E
2014-11-01
Forty-four Holstein calves were fed a direct-fed microbial (DFM) and 1 of 2 milk replacers to evaluate calf performance and growth. Treatments were (1) a control milk replacer [22:20; 22% crude protein (CP) and 20% fat], (2) an accelerated milk replacer (27:10; 27% CP and 10% fat), (3) the control milk replacer with added DFM (22:20+D), and (4) the accelerated milk replacer with added DFM (27:10+D). Dry matter intake, rectal temperatures, respiration scores and rates, and fecal scores were collected daily. Body weight, hip and withers height, heart girth, blood, and rumen fluid samples were collected weekly. Effects of treatment, sex, week, and their interactions were analyzed. Calves fed an accelerated milk replacer, regardless of DFM supplementation, consumed more CP and metabolizable energy in the milk replacer. No treatment differences were found for starter intake or intake of neutral detergent fiber or acid detergent fiber in the starter. Calves fed the accelerated milk replacer had greater preweaning and weaning body weight compared with calves fed the control milk replacer. Average daily gain was greater during the preweaning period for calves fed the accelerated milk replacer, but the same pattern did not hold true during the postweaning period. Feed efficiency did not differ among treatments. Hip height tended to be and withers height and heart girth were greater at weaning for calves fed the accelerated milk replacer compared with calves fed the control milk replacer. Fecal scores were greatest in calves fed DFM. Overall acetate, propionate, butyrate, and n-valerate concentrations were lower in calves fed the accelerated milk replacer, but DFM did not have an effect. Rumen pH was not different. Blood metabolites were unaffected by DFM supplementation, but calves fed the accelerated milk replacer had increased partial pressure of CO2, bicarbonate, and total bicarbonate in the blood. Direct-fed microbial supplementation did not appear to benefit the calf in this trial. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Effect of DHEA on Bone in Young Adults
1999-09-01
material from female subjects undergoing total hip replacement. Low-density mononuclear cells were isolated by centrifugation on Ficoll histopaque...affected genetic males that is similar to that of unaffected female animals (56). Another natural model is the case of a man with an estrogen receptor...transgenic estrogen receptor knockout mouse, has a BMD 20-25% that of normal mice (58). Similarly, male and female patients with aromatase deficiency have
[Acute angle-closure glaucoma after total hip replacement surgery].
Ujino, H; Morimoto, O; Yukioka, H; Fujimori, M
1997-06-01
Acute angle-closure glaucoma is a rare complication of surgery. We experienced a case of postoperative acute glaucoma after total hip replacement under general anesthesia. A 49-year-old female without signs or symptoms of glaucoma was premedicated with the intramuscular administration of secobarbital, atropine and ranitidine. Following rapid induction with thiopental and vecuronium, anesthesia was maintained with N2O-O2-sevoflurane. PGE1 was administered intravenously for induced hypotension during the surgery. Hemorrhagic shock with a systolic blood pressure of 60 mmHg continued for 15 min during the surgery. Large amounts of fluid and ephedrine were required for treating this hypotensive episode. Vecuronium was reversed by bolus injection of neostigmine and atropine at the end of surgery. Soon after recovery from anesthesia, she complained of pain and blurred vision in her both eyes. The consulting ophthalmologist made a diagnosis of acute glaucoma due to high intraocular pressure (IOP). Treatment with glycerol and pilocarpine had no effect on the elevated IOP. The laser iridotomy performed on her at 5th and 7th post-operative days improved her vision completely. The post-operative glaucoma may cause serious permanent loss of vision. An early diagnosis of this post-operative complication and its treatment with drugs and surgery should be emphasized.
The principle of low frictional torque in the Charnley total hip replacement.
Wroblewski, B M; Siney, P D; Fleming, P A
2009-07-01
The design of the Charnley total hip replacement follows the principle of low frictional torque. It is based on the largest possible difference between the radius of the femoral head and that of the outer aspect of the acetabular component. The aim is to protect the bone-cement interface by movement taking place at the smaller radius, the articulation. This is achieved in clinical practice by a 22.225 mm diameter head articulating with a 40 mm or 43 mm diameter acetabular component of ultra-high molecular weight polyethylene. We compared the incidence of aseptic loosening of acetabular components with an outer diameter of 40 mm and 43 mm at comparable depths of penetration with a mean follow-up of 17 years (1 to 40). In cases with no measurable wear none of the acetabular components were loose. With increasing acetabular penetration there was an increased incidence of aseptic loosening which reflected the difference in the external radii, with 1.5% at 1 mm, 8.8% at 2 mm, 9.7% at 3 mm and 9.6% at 4 mm of penetration in favour of the larger 43 mm acetabular component. Our findings support the Charnley principle of low frictional torque. The level of the benefit is in keeping with the predicted values.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anthony, P.; Keys, H.; Evarts, C.M.
1987-03-01
Prior studies have demonstrated the effectiveness of postoperative radiation therapy (RT) to the hip area following total hip replacement (THR) surgery in preventing the development of heterotopic bone formation in patients considered to be at high risk for development of this complication. Previously, patients received 20.00 Gy in 10 fractions (fx) over 2 weeks, beginning as soon postop as medically feasible (usually post-op day 2). In an effort to reduce hospital stay and risk of secondary malignancy, a prospective treatment program was initiated April 1982 using a reduced dose of 10.00 Gy in 5 fx over 5-7 days. As ofmore » February 1984, 46 consecutive hips determined to be at high risk were treated with this reduced dose. Prior studies have demonstrated that heterotopic bone is always radiographically evident by 8 weeks. Of the 46 hips, 41 had been evaluated with the minimum required 8 week follow-up X ray. Twenty-five of these hips, 61%, had a mean long term follow-up of 12 months. It historical control group, consisting of 54 consecutive high risk post-THR's, was shown to have a 68.5% incidence of heterotopic bone. The 20.00 Gy group, when RT was started by post-op day 5, demonstrated a 3.2% incidence, compared to 4.9% in the 10.00 Gy group. Complication rates were also comparable in the two RT groups, 19.4% and 7.3% respectively; 10.00 Gy is apparently as effective as 20.00 Gy in preventing heterotopic bone formation in high risk post-THR patients.« less
Steinberg, Julia; Shah, Karan M.; Gartland, Alison; Zeggini, Eleftheria
2017-01-01
ABSTRACT Metal‐on‐metal (MOM) hip resurfacing has recently been a popular prosthesis choice for the treatment of symptomatic arthritis, but results in the release of cobalt and chromium ions into the circulation that can be associated with adverse clinical effects. The mechanism underlying these effects remains unclear. While chromosomal aneuploidy and translocations are associated with this exposure, the presence of subtle structural epigenetic modifications in patients with MOM joint replacements remains unexplored. Consequently, we analyzed whole blood DNA methylation in 34 OA patients with MOM hip resurfacing (MOM HR) compared to 34 OA patients with non‐MOM total hip replacements (non‐MOM THR), using the genome‐wide Illumina HumanMethylation 450k BeadChip. No probes showed differential methylation significant at 5% false‐discovery rate (FDR). We also tested association of probe methylation levels with blood chromium and cobalt levels directly; there were no significant associations at 5% FDR. Finally, we used the “epigenetic clock” to compare estimated to actual age at sample for all individuals. We found no significant difference between MOM HR and non‐MOM THR, and no correlation of age acceleration with blood metal levels. Our results suggest the absence of large methylation differences systemically following metal exposure, however, larger sample sizes will be required to identify potential small effects. Any DNA methylation changes that may occur in the local periprosthetic tissues remain to be elucidated. © 2017 The Authors. Orthopaedic Research Society. Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 35:2323–2328, 2017. PMID:28098396
Personality, function and satisfaction in patients undergoing total hip or knee replacement.
Ramaesh, Rishikesan; Jenkins, Paul; Lane, Judith V; Knight, Sara; Macdonald, Deborah; Howie, Colin
2014-03-01
The aim of this study was to investigate the relationships between personality and joint-specific function, general physical and general mental health in patients undergoing total hip (THA) and knee arthroplasty (TKA). One hundred and eighty-four patients undergoing THA and 205 undergoing TKA were assessed using the Eysneck Personality Questionnaire, brief version (EPQ-BV). General physical and mental health was measured using the Short-Form 12 (SF-12) questionnaire and the EuroQol (EQ-5D). Joint-specific function was measured using the Oxford hip or knee score. The "unstable introvert" personality type was associated with poorer pre-operative function and health in patients with hip arthrosis. In patients with knee arthrosis, there was poorer general health in those with "stable extrovert" and "unstable introvert" types. Personality was not an independent predictor of outcome following TKA or THA. The main predictor was pre-operative function and health. Comorbidity was an important covariate of both pre-operative and postoperative function. Personality may play a role in the interaction of these disease processes with function and health perception. It may also affect the response and interpretation of psychometric and patient-reported outcome measures. It may be important to characterise and identify these traits in potential arthroplasty patients as it may help deliver targeted education and management to improve outcomes in certain groups.
Mason, James; Baker, Paul; Gregg, Paul J; Porter, Martyn; Deehan, David J; Reed, Mike R
2015-01-01
Background and purpose The optimal hip replacement for young patients remains unknown. We compared patient-reported outcome measures (PROMs), revision risk, and implant costs over a range of hip replacements. Methods We included hip replacements for osteoarthritis in patients under 60 years of age performed between 2003 and 2010 using the commonest brand of cemented, cementless, hybrid, or resurfacing prosthesis (11,622 women and 13,087 men). The reference implant comprised a cemented stem with a conventional polyethylene cemented cup and a standard-sized head (28- or 32-mm). Differences in implant survival were assessed using competing-risks models, adjusted for known prognostic influences. Analysis of covariance was used to assess improvement in PROMs (Oxford hip score (OHS) and EQ5D index) in 2014 linked procedures. Results In males, PROMs and implant survival were similar across all types of implants. In females, revision was statistically significantly higher in hard-bearing and/or small-stem cementless implants (hazard ratio (HR) = 4) and resurfacings (small head sizes (< 48 mm): HR = 6; large head sizes (≥ 48 mm): HR = 5) when compared to the reference cemented implant. In component combinations with equivalent survival, women reported significantly greater improvements in OHS with hybrid implants (22, p = 0.006) and cementless implants (21, p = 0.03) (reference, 18), but similar EQ5D index. For men and women, National Health Service (NHS) costs were lowest with the reference implant and highest with a hard-bearing cementless replacement. Interpretation In young women, hybrids offer a balance of good early functional improvement and low revision risk. Fully cementless and resurfacing components are more costly and do not provide any additional benefit for younger patients. PMID:25285617
Nelson, Amanda E; Golightly, Yvonne M; Renner, Jordan B; Schwartz, Todd A; Liu, Felix; Lynch, John A; Gregory, Jenny S; Aspden, Richard M; Lane, Nancy E; Jordan, Joanne M
2016-02-01
Hip shape by statistical shape modeling (SSM) is associated with hip radiographic osteoarthritis (rOA). We examined associations between hip shape and knee rOA given the biomechanical interrelationships between these joints. Bilateral baseline hip shape assessments [for those with at least 1 hip with a Kellgren-Lawrence arthritis grading scale (KL) 0 or 1] from the Johnston County Osteoarthritis Project were available. Proximal femur shape was defined on baseline pelvis radiographs and evaluated by SSM, producing mean shape and continuous variables representing independent modes of variation (14 modes = 95% of shape variance). Outcomes included prevalent [baseline KL ≥ 2 or total knee replacement (TKR)], incident (baseline KL 0/1 with followup ≥ 2), and progressive knee rOA (KL increase of ≥ 1 or TKR). Limb-based logistic regression models for ipsilateral and contralateral comparisons were adjusted for age, sex, race, body mass index (BMI), and hip rOA, accounting for intraperson correlations. We evaluated 681 hips and 682 knees from 342 individuals (61% women, 83% white, mean age 62 yrs, BMI 29 kg/m(2)). Ninety-nine knees (15%) had prevalent rOA (4 knees with TKR). Lower modes 2 and 3 scores were associated with ipsilateral prevalent knee rOA, and only lower mode 3 scores were associated with contralateral prevalent knee rOA. No statistically significant associations were seen for incident or progressive knee rOA. Variations in hip shape were associated with prevalent, but not incident or progressive, knee rOA in this cohort, and may reflect biomechanical differences between limbs, genetic influences, or common factors related to both hip shape and knee rOA.
A2-3: Impact of Mild Chronic Kidney Disease Stage on Outcomes after Total Hip or Knee Arthroplasty
Graham, Jove; Deegan, Brian; Bowen, Thomas; Richard, Raveesh; Perkins, Robert; Foltzer, Michael
2014-01-01
Background/Aims Dialysis and kidney transplantation adversely impact outcomes of total hip or knee arthroplasty (THA, TKA), but complication rates have not been reported for patients with less advanced stages of chronic kidney disease (CKD). Surgeons lack the data necessary to have informed discussions regarding anticipated outcomes of joint replacement for these patients. Methods We retrospectively reviewed electronic health records of 779 adults with stages 1, 2, and 3 CKD not requiring dialysis or transplantation who underwent THA or TKA from 2004–2011, to assess infection, revision, 90-day readmission and mortality rates. Patients with less than 12 months follow-up, open fracture, prior joint surgery, pregnancy, or acute kidney injury were excluded. Chi-square analysis and Cox survival analysis compared these outcomes between the stage 1–2 and stage 3 groups, stratified by joint replaced (THA vs TKA). All models adjusted for age, sex and BMI at surgery. Results No statistically different rates of revision or infection between Stage 3 vs. Stages 1–2 were seen, although there was a trend toward increased infections in Stage 3. THA patients with Stage 3 showed a significantly increased mortality rate compared to Stage 1–2 THA patients (HR 3.40, 95% CI = 1.25–9.23, P = 0.02). Conclusions CKD affects nearly 15% of the U.S. population many of whom undergo joint replacement. End stage kidney disease (patients post-transplant or on hemodialysis) has been consistently associated with increased rates of infection and revision in excess of our observed outcomes, but the overall rate of infection/revision in our study population was only slightly higher than reported rates in the general population (2–7% vs. 1–2%, respectively). CKD should not preclude joint replacement, but these data can help clinicians engage in meaningful informed discussions with patients with mild kidney disease regarding risks for infection, revision and death following joint replacement.
Knee joint effusion following ipsilateral hip surgery.
Christodoulou, A G; Givissis, P; Antonarakos, P D; Petsatodis, G E; Hatzokos, I; Pournaras, J D
2010-12-01
To correlate patellar reflex inhibition with sympathetic knee joint effusion. 65 women and 40 men aged 45 to 75 (mean, 65) years underwent hip surgery. The surgery entailed dynamic hip screw fixation using the lateral approach with reflection of the vastus lateralis for pertrochantric fractures (n = 49), and hip hemiarthroplasty or total hip replacement using the Watson-Jones approach (n = 38) or hip hemiarthroplasty using the posterior approach (n = 18) for subcapital femoral fractures (n = 28) or osteoarthritis (n = 28). Knee joint effusion, patellar reflex, and thigh circumference were assessed in both legs before and after surgery (at day 0.5, 2, 7, 14, 30, and 45). Time-sequence plots were used for chronological analysis, and correlation between patellar reflex inhibition and knee joint effusion was tested. In the time-sequence plot, the peak frequency of patellar reflex inhibition (on day 0.5) preceded that of the knee joint effusion and the thigh circumference increase (on day 2). Patellar reflex inhibition correlated positively with the knee joint effusion (r = 0.843, p = 0.035). These 2 factors correlated significantly for all 3 surgical approaches (p < 0.0005). All 3 approaches were associated with patellar reflex inhibition on day 0.5 (p = 0.033) and knee joint effusion on day 2 (p = 0.051). Surgical trauma of the thigh may cause patellar reflex inhibition and subsequently knee joint effusion.
Reijman, M; Hazes, J M W; Pols, H A P; Bernsen, R M D; Koes, B W; Bierma-Zeinstra, S M A
2004-11-01
To compare the reliability and validity in a large open population of three frequently used radiological definitions of hip osteoarthritis (OA): Kellgren and Lawrence grade, minimal joint space (MJS), and Croft grade; and to investigate whether the validity of the three definitions of hip OA is sex dependent. from the Rotterdam study (aged > or= 55 years, n = 3585) were evaluated. The inter-rater reliability was tested in a random set of 148 x rays. The validity was expressed as the ability to identify patients who show clinical symptoms of hip OA (construct validity) and as the ability to predict total hip replacement (THR) at follow up (predictive validity). Inter-rater reliability was similar for the Kellgren and Lawrence grade and MJS (kappa statistics 0.68 and 0.62, respectively) but lower for Croft's grade (kappa statistic, 0.51). The Kellgren and Lawrence grade and MJS showed the strongest associations with clinical symptoms of hip OA. Sex appeared to be an effect modifier for Kellgren and Lawrence and MJS definitions, women showing a stronger association between grading and symptoms than men. However, the sex dependency was attributed to differences in height between women and men. The Kellgren and Lawrence grade showed the highest predictive value for THR at follow up. Based on these findings, Kellgren and Lawrence still appears to be a useful OA definition for epidemiological studies focusing on the presence of hip OA.
Factors influencing initial cup stability in total hip arthroplasty.
Amirouche, Farid; Solitro, Giovanni; Broviak, Stefanie; Gonzalez, Mark; Goldstein, Wayne; Barmada, Riad
2014-12-01
One of the main goals in total hip replacement is to preserve the integrity of the hip kinematics, by well positioning the cup and to make sure its initial stability is congruent and attained. Achieving the latter is not trivial. A finite element model of the cup-bone interface simulating a realistic insertion and analysis of different scenarios of cup penetration, insertion, under-reaming and loading is investigated to determine certain measurable factors sensitivity to stress-strain outcome. The insertion force during hammering and its relation to the cup penetration during implantation is also investigated with the goal of determining the initial stability of the acetabular cup during total hip arthroplasty. The mathematical model was run in various configurations to simulate 1 and 2mm of under-reaming at various imposed insertion distances to mimic hammering and insertion of cup insertion into the pelvis. Surface contact and micromotion at the cup-bone interface were evaluated after simulated cup insertion and post-operative loading conditions. The results suggest a direct correlation between under-reaming and insertion force used to insert the acetabular cup on the micromotion and fixation at the cup-bone interface. While increased under-reaming and insertion force result in an increase amount of stability at the interface, approximately the same percentage of surface contact and micromotion reduction can be achieved with less insertion force. We need to exercise caution to determine the optimal configuration which achieves a good conformity without approaching the yield strength for bone. Copyright © 2014 Elsevier Ltd. All rights reserved.
Effect of tranexamic acid administration on bleeding in primary total hip arthroplasty.
Fernández-Cortiñas, A B; Quintáns-Vázquez, J M; Gómez-Suárez, F; Murillo, O Simón; Sánchez-López, B R; Pena-Gracía, J M
To study the efficacy of tranexamic acid to decrease perioperative bleeding in patients who have undergone a total hip arthroplasty operation and to evaluate drug safety. Observational, prospective, controlled and randomized study on the efficacy of tranexamic acid as a method to reduce bleeding in primary hip replacement surgery. We included 134 patients operated during 2014 in our centre, who were divided into 2 groups according to whether or not they had received tranexamic acid. The main study variables were haemoglobin and haematocrit levels, the amount of blood collected from the post-operative drain in the first 12, 24 and 48hours and transfusion requirements. Post-operative haemoglobin and haematocrit levels were statistically higher (P<.001) in the group with treatment. During the first 48hours bleeding values from the group that did not receive TAX were higher compared to patients treated with tranexamic acid. Statistically significant differences (P=.001) were found as to the need for transfusion according to group, more transfusions were performed in the cohort that had not received tranexamic acid: 25.37% compared to 4.48% for the group with tranexamic acid. No adverse events related to administration of tranexamic acid were recorded. Administration of tranexamic acid has proved to be an effective and safe method to reduce peri-operative bleeding in patients who underwent total hip arthroplasty and avoids allogenic blood transfusion. Therefore, tranexamic acid treatment could entail a financial saving for the healthcare system and expose the patient to less risk. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
Subsequent Total Joint Arthroplasty After Primary Total Knee or Hip Arthroplasty
Sanders, Thomas L.; Maradit Kremers, Hilal; Schleck, Cathy D.; Larson, Dirk R.; Berry, Daniel J.
2017-01-01
Background: Despite the large increase in total hip arthroplasties and total knee arthroplasties, the incidence and prevalence of additional contralateral or ipsilateral joint arthroplasty are poorly understood. The purpose of this study was to determine the rate of additional joint arthroplasty after a primary total hip arthroplasty or total knee arthroplasty. Methods: This historical cohort study identified population-based cohorts of patients who underwent primary total hip arthroplasty (n = 1,933) or total knee arthroplasty (n = 2,139) between 1969 and 2008. Patients underwent passive follow-up through their medical records beginning with the primary total hip arthroplasty or total knee arthroplasty. We assessed the likelihood of undergoing a subsequent total joint arthroplasty, including simultaneous and staged bilateral procedures. Age, sex, and calendar year were evaluated as potential predictors of subsequent arthroplasty. Results: During a mean follow-up of 12 years after an initial total hip arthroplasty, we observed 422 contralateral total hip arthroplasties (29% at 20 years), 76 contralateral total knee arthroplasties (6% at 10 years), and 32 ipsilateral total knee arthroplasties (2% at 20 years). Younger age was a significant predictor of contralateral total hip arthroplasty (p < 0.0001), but not a predictor of the subsequent risk of total knee arthroplasty. During a mean follow-up of 11 years after an initial total knee arthroplasty, we observed 809 contralateral total knee arthroplasties (45% at 20 years), 31 contralateral total hip arthroplasties (3% at 20 years), and 29 ipsilateral total hip arthroplasties (2% at 20 years). Older age was a significant predictor of ipsilateral or contralateral total hip arthroplasty (p < 0.001). Conclusions: Patients undergoing total hip arthroplasty or total knee arthroplasty can be informed of a 30% to 45% chance of a surgical procedure in a contralateral cognate joint and about a 5% chance of a surgical procedure in noncognate joints within 20 years of initial arthroplasty. Increased risk of contralateral total knee arthroplasty following an initial total hip arthroplasty may be due to gait changes prior to and/or following total hip arthroplasty. The higher prevalence of bilateral total hip arthroplasty in younger patients may result from bilateral disease processes that selectively affect the young hip, such as osteonecrosis, or structural hip problems, such as acetabular dysplasia or femoroacetabular impingement. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. PMID:28244910
Agins, H J; Alcock, N W; Bansal, M; Salvati, E A; Wilson, P D; Pellicci, P M; Bullough, P G
1988-03-01
We conducted extensive histological examination of the tissues that were adjacent to the prosthesis in nine hips that had a failed total arthroplasty. The prostheses were composed of titanium alloy (Ti-6Al-4V) and ultra-high molecular weight polyethylene. The average time that the prosthesis had been in place in the tissue was 33.5 months (range, eleven to fifty-seven months). Seven arthroplasties were revised because of aseptic loosening and two, for infection. In eight hips cement had been used and in one (that had a porous-coated implant for fifty-two months) no cement had been utilized. Intense histiocytic and plasma-cell reaction was noted in the pseudocapsular tissue. There was copious metallic staining of the lining cells. Polyethylene debris and particles of cement with concomitant giant-cell reaction were present in five hips. Atomic absorption spectrophotometry revealed values for titanium of fifty-sic to 3700 micrograms per gram of dry tissue (average, 1047 micrograms per gram; normal, zero microgram per gram), for aluminum of 2.1 to 396 micrograms per gram (average, 115 micrograms per gram; normal, zero micrograms per gram), and for vanadium of 2.9 to 220 micrograms per gram (average, sixty-seven micrograms per gram; normal, 1.2 micrograms per gram). The highest values were found in the hip in which surgical revision was performed at fifty-seven months. The concentrations of the three elements in the soft tissues were similar to those in the metal of the prostheses. The factors to which failure was attributed were: vertical orientation of the acetabular component (five hips), poor cementing technique on the femoral side (three hips), infection (two hips), and separation of a sintered pad made of pure titanium (one hip). A femoral component that is made of titanium alloy can undergo severe wear of the surface and on the stem, where it is loose, with liberation of potentially toxic local concentrations of metal debris into the surrounding tissues. It may contribute to infection and loosening.
Osnes-Ringen, H; Kvamme, M K; Kristiansen, I S; Thingstad, M; Henriksen, J E; Kvien, T K; Dagfinrud, H
2011-03-01
To examine the costs per quality-adjusted life year (QALY) gained for surgical interventions in patients with inflammatory arthropathies, and to compare the costs per QALY gained for replacement versus non-replacement surgical interventions. In total, 248 patients [mean age 57 (SD 13) years, 77% female] with inflammatory arthropathies underwent orthopaedic surgical treatment and responded to mail surveys at baseline and during follow-up (3, 6, 9, and 12 months). Questionnaires included the quality-of-life EuroQol-5D (EQ-5D) and Short Form-6D (SF-6D) utility scores. The health benefit from surgery was subsequently translated into QALYs. The direct treatment costs in the first year were, for each patient, derived from the hospital's cost per patient accounting system (KOSPA). The costs per QALY were estimated and future costs and benefits were discounted at 4%. Improvement in utility at 1-year follow-up was 0.10 with EQ-5D and 0.03 with SF-6D (p < 0.05). The estimated 10-year cost per QALY gained was EUR 5000 for hip replacement surgery (EUR18 600 using SF-6D) and EUR 10 500 (EUR 48 500 using SF-6D) for all replacement procedures. The 5-year cost per QALY was EUR 17 800 for non-replacement surgical procedures measured by EQ-5D (SF-6D: EUR 67 500). Elective orthopaedic surgery in patients with inflammatory arthropathies was cost-effective when measured with EQ-5D, and some procedures were also cost-effective when SF-6D was used in the economic evaluations. Hip replacement surgery was most cost-effective, irrespective of the method of analysis.
Guicherd, W; Bonin, N; Gicquel, T; Gedouin, J E; Flecher, X; Wettstein, M; Thaunat, M; Prevost, N; Ollier, E; May, O
2017-12-01
Impingement between the acetabular component and the iliopsoas tendon is a cause of anterior pain after total hip replacement (THR). Treatment can be non-operative, endoscopic or arthroscopic, or by open revision of the acetabular component. Few studies have assessed these options. The present study hypothesis was that endo/arthroscopic treatment provides rapid pain relief with a low rate of complications. A prospective multicenter study included 64 endoscopic or arthroscopic tenotomies for impingement between the acetabular component and the iliopsoas tendon, performed in 8 centers. Mean follow-up was 8months, with a minimum of 6months and no loss to follow-up. Oxford score, patient satisfaction, anterior pain and iliopsoas strength were assessed at last follow-up. Complications and revision procedures were collated. Forty-four percent of patients underwent rehabilitation. At last follow-up, 92% of patients reported pain alleviation. Oxford score, muscle strength and pain in hip flexion showed significant improvement. The complications rate was 3.2%, with complete resolution. Mean hospital stay was 0.8 nights. In 2 cases, arthroscopy revealed metallosis, indicating revision of the acetabular component. The only predictive factor was acetabular projection on oblique view. Rehabilitation significantly improved muscle strength. Endoscopic or arthroscopic tenotomy for impingement between the acetabular component and the iliopsoas tendon following THR significantly alleviated anterior pain in more than 92% of cases. The low complications rate makes this the treatment of choice in case of failure of non-operative management. Arthroscopy also reorients diagnosis in case of associated joint pathology. Projection of the acetabular component on preoperative oblique view is the most predictive criterion, guiding treatment. Copyright © 2017. Published by Elsevier Masson SAS.
Kosek, E; Roos, E M; Ageberg, E; Nilsdotter, A
2013-09-01
To assess exercise induced analgesia (EIA) and pain sensitivity in hip and knee osteoarthritis (OA) and to study the effects of neuromuscular exercise and surgery on these parameters. The dataset consisted of knee (n = 66) and hip (n = 47) OA patients assigned for total joint replacement at Lund University Hospital undergoing pre-operative neuromuscular exercise and 43 matched controls. Sensitivity to pressure pain was assessed by pressure algometry at 10 sites. Subjects were then instructed to perform a standardized static knee extension. Pressure pain thresholds (PPTs) were assessed at the contracting quadriceps muscle (Q) and at the resting deltoid muscle (D) before and during contraction. The relative increase in PPTs during contraction was taken as a measure of localized (Q) or generalized (D) EIA. Patients were assessed at baseline, following on average 12 weeks of neuromuscular exercise and 3 months following surgery. We found a normal function of EIA in OA patients at baseline. Previous studies have reported beneficial effects of physical exercise on pain modulation in healthy subjects. However, no treatment effects on EIA were seen in OA patients despite the increase in muscle strength following neuromuscular exercise and reduced pain following surgery. Compared to controls, OA patients had increased pain sensitivity and no beneficial effects on pain sensitivity were seen following treatment. To our knowledge, this is the first study of EIA in OA patients. Despite increased pain sensitivity, OA patients had a normal function of EIA. Copyright © 2013 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Shadyab, A H; Terkeltaub, R; Kooperberg, C; Reiner, A; Eaton, C B; Jackson, R D; Krok-Schoen, J L; Salem, R M; LaCroix, A Z
2018-05-22
To examine associations of high-sensitivity C-reactive protein (CRP) levels and polygenic CRP genetic risk scores (GRS) with risk of end-stage hip or knee osteoarthritis (OA), defined as incident total hip (THR) or knee replacement (TKR) for OA. This study included a cohort of postmenopausal white, African American, and Hispanic women from the Women's Health Initiative. Women were followed from baseline to date of THR or TKR, death, or December 31, 2014. Medicare claims data identified THR and TKR. Hs-CRP and genotyping data were collected at baseline. Three CRP GRS were constructed: 1) a 4-SNP GRS comprised of genetic variants representing variation in the CRP gene among European populations; 2) a multilocus 18-SNP GRS of genetic variants significantly associated with CRP levels in a meta-analysis of genome-wide association studies; and 3) a 5-SNP GRS of genetic variants significantly associated with CRP levels among African American women. In analyses conducted separately among each race and ethnic group, there were no significant associations of ln hs-CRP with risk of THR or TKR, after adjusting for age, body mass index, lifestyle characteristics, chronic diseases, hormone therapy use, and non-steroidal anti-inflammatory drug use. CRP GRS were not associated with risk of THR or TKR in any ethnic group. Serum levels of ln hs-CRP and genetically-predicted CRP levels were not associated with risk of THR or TKR for OA among a diverse cohort of women. Copyright © 2018 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Interventions for Hip Pain in the Maturing Athlete
Gomberawalla, M. Mustafa; Kelly, Bryan T.; Bedi, Asheesh
2014-01-01
Context: Femoroacetabular impingement (FAI) alters hip mechanics, results in hip pain, and may lead to secondary osteoarthritis (OA) in the maturing athlete. Hip impingement can be caused by osseous abnormalities in the proximal femur or acetabulum. These impingement lesions may cause altered loads within the hip joint, which result in repetitive collision damage or sheer forces to the chondral surfaces and acetabular labrum. These anatomic lesions and resultant abnormal mechanics may lead to early osteoarthritic changes. Evidence Acquisition: Relevant articles from the years 1995 to 2013 were identified using MEDLINE, EMBASE, and the bibliographies of reviewed publications. Level of Evidence: Level 4. Results: Improvements in hip arthroscopy have allowed FAI to be addressed utilizing the arthroscope. Adequately resecting the underlying osseous abnormalities is essential to improving hip symptomatology and preventing further chondral damage. Additionally, preserving the labrum by repairing the damaged tissue and restoring the suction seal may theoretically help normalize hip mechanics and prevent further arthritic changes. The outcomes of joint-preserving treatment options may be varied in the maturing athlete due to the degree of underlying OA. Irreversible damage to the hip joint may have already occurred in patients with moderate to advanced OA. In the presence of preexisting arthritis, these patients may only experience fair or even poor results after hip arthroscopy, with early conversion to hip replacement. For patients with advanced hip arthritis, total hip arthroplasty remains a treatment option to reliably improve symptoms with good to excellent outcomes and return to low-impact activities. Conclusion: Advances in the knowledge base and treatment techniques of intra-articular hip pain have allowed surgeons to address this complex clinical problem with promising outcomes. Traditionally, open surgical dislocations for hip preservation surgery have shown good long-term results. Improvements in hip arthroscopy have led to outcomes equivalent to open surgery while utilizing significantly less invasive techniques. However, outcomes may ultimately depend on the degree of underlying OA. When counseling the mature athlete with hip pain, an understanding of the underlying anatomy, degree of arthritis, and expectations will help guide the treating surgeon in offering appropriate treatment options. PMID:24427445
Importance of preclinical evaluation of wear in hip implant designs using simulator machines.
Trommer, Rafael Mello; Maru, Márcia Marie
2017-01-01
Total hip arthroplasty (THA) is a surgical procedure that involves the replacement of the damaged joint of the hip by an artificial device. Despite the recognized clinical success of hip implants, wear of the articulating surfaces remains as one of the critical issues influencing performance. Common material combinations used in hip designs comprise metal-on-polymer (MoP), ceramic-on-polymer (CoP), metal-on-metal (MoM), and ceramic-on-ceramic (CoC). However, when the design of the hip implant is concerned besides the materials used, several parameters can influence its wear performance. In this scenario, where the safety and efficacy for the patient are the main issues, it is fundamental to evaluate and predict the wear rate of the hip implant design before its use in THA. This is one of the issues that should be taken into account in the preclinical evaluation step of the product, in which simulated laboratory tests are necessary. However, it is fundamental that the applied motions and loads can reproduce the wear mechanisms physiologically observed in the patient. To replicate the in vivo angular displacements and loadings, special machines known as joint simulators are employed. This article focuses on the main characteristics related to the wear simulation of hip implants using mechanical simulators, giving information to surgeons, researchers, regulatory bodies, etc., about the importance of preclinical wear evaluation. A critical analysis is performed on the differences in the principles of operation of simulators and their effects on the final results, and about future trends in wear simulation.
Bergin, Carole; Speroni, Karen Gabel; Travis, Tom; Bergin, John; Sheridan, Michael J; Kelly, Karen; Daniel, Marlon G
2014-02-01
This study examined the effects of preoperative incentive spirometry (IS) education (POISE) on postoperative outcomes for knee and hip total joint replacement patients. In this prospective study, 140 patients were randomized to Group 1 (POISE intervention = 50 completing) or Group 2 (no intervention = 56 completing) (34 dropped). The Group 1 intervention consisted of formal instruction preoperatively for IS home use, postoperative use, and IS volumes documentation. Group 2 patients received no intervention. Patients recorded postoperative IS volumes, which were used to determine return to baseline volume. One hundred six patients completed the study. Most were Caucasian females averaging 64 years. Although IS return to baseline volume time was not significantly different between groups, POISE patients had fewer postoperative complications, hospital days, and charges. POISE patients ranked the intervention as helpful. Although IS volumes were not significantly different between groups, POISE patients had better outcomes and ranked the intervention as helpful. Copyright © 2014 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.
Bieler, Theresa; Magnusson, Stig Peter; Christensen, Helle Elisabeth; Kjaer, Michael; Beyer, Nina
2017-07-01
To investigate between-leg differences in hip and thigh muscle strength and leg extensor power in patients with unilateral hip osteoarthritis. Further, to compare between-leg differences in knee extensor strength and leg extensor power between patients and healthy peers. Seventy-two patients (60-87 years) with radiographic and symptomatic hip osteoarthritis not awaiting hip replacement and 35 healthy peers (63-82 years) were included. Hip and thigh muscle strength and leg extensor power were measured in patients and knee extensor strength and leg extensor power in healthy. The symptomatic extremity in patients was significantly (p < 0.05, paired t-test) weaker compared with the non-symptomatic extremity for five hip muscles (8-17%), knee extensors (11%) and leg extensor power (19%). Healthy older adults had asymmetry in knee extensor strength (6%, p < 0.05) comparable to that found in patients, but had no asymmetry in leg extensor power. Patients had generalized weakening of the affected lower extremity and numerically the largest asymmetry was evident for leg extensor power. In contrast, healthy peers had no asymmetry in leg extensor power. These results indicate that exercise interventions focusing on improving leg extensor power of the symptomatic lower extremity and reducing asymmetry may be beneficial for patients with hip osteoarthritis. Implications for Rehabilitation Even in patients with mild symptoms not awaiting hip replacement a generalized muscle weakening of the symptomatic lower extremity seems to be present. Between-leg differences in leg extensor power (force × velocity) appears to be relatively large (19%) in patients with unilateral hip osteoarthritis in contrast to healthy peers who show no asymmetry. Compared to muscle strength the relationship between functional performance and leg extensor power seems to be stronger, and more strongly related to power of the symptomatic lower extremity. Our results indicate that exercise interventions focusing on improving leg extensor power of the symptomatic lower extremity and reducing asymmetry may be beneficial for patients with mild symptoms not awaiting hip replacement.
Al Omran, Abdullah
2013-05-01
Sickle cell disease (SCD) is the most common cause of avascular necrosis of femoral head (ANFH) in childhood. Advances in medical treatment led to improved life expectancy of such patients. SCD-related ANFH frequently progress to total collapse of the femoral head necessitating hip replacement. However, SCD patient are at more risk of intra- and post-operative complications and suboptimal outcome of total hip arthroplasty. Hence, it is imperative to preserve the femoral head as long as possible. Between September 1992 and June 2007, 94 core decompression procedures were done to SCD patients who had modified Ficat stage I, IIA and IIB ANFH. Sixty one patients underwent a classical 8-mm drilling and 33 patients underwent 3.2-mm diameter MD technique. Patients were followed up for minimum of 2 years and were evaluated for clinical and Harris Hip Score improvement and for radiological progression. All 19 hips that had Ficat stage I had significant reduction of pain and improvement of Harris Hip Score. No patient has required further surgery. Among the 39 hips with Ficat IIA at time of procedure, 80 % of hips which underwent CD and 78 % of MD cases had significant reduction of pain and improvement of HHS. Those patients showed no radiographic progression of the disease. The remaining, 20 % CD and 22 % MD eventually progressed radiologically to grade III or grade IV and had HHS less than 75 at last visit. In the 36 cases with Ficat IIB, 52 % CD and 52.8 % MC had significant reduction of pain and improvement of HHS. The rest showed no improvement in pain and function, and progressed to stage IV; 11 of them underwent THA and one patient refused surgery. While multiple drilling is safer and less invasive than single coring in SCD, there is no statistically significant difference in outcome or complication rate between both procedures done for ANFH in patients with SCD.
Hammett, Thomas; Simonian, Aram; Austin, Monica; Butler, Robert; Allen, Kelli D; Ledbetter, Leila; Goode, Adam P
2018-06-01
Little is known about the extent to which physical activity (PA) levels change following total knee or hip joint replacement relative to pain, physical function, and quality of life. Our objective was to conduct a systematic review and meta-analysis on changes in PA relative to pain, quality of life, and physical function after total knee or hip joint replacement. We searched the PubMed (Medline), Embase, and CINAHL databases for peer-reviewed, English-language cohort studies measuring PA with an accelerometer from presurgery to postsurgery. Random-effects models were used to produce standardized mean differences (SMDs) for PA, quality of life, pain, and physical function outcomes. Heterogeneity was assessed using I 2 . Seven studies (336 participants) met the eligibility criteria. No significant increase in PA was found at 6 months (SMD 0.14 [95% confidence interval (95% CI) -0.05, 0.34]; I 2 = 0%) and a small to moderately significant effect was found for increasing PA at 12 months (SMD 0.43 [95% CI 0.22, 0.64]; I 2 = 0%). Large improvements were found at 6 months in physical function (SMD 0.97 [95% CI 0.12, 1.82]; I 2 = 92.3%), pain (SMD -1.47 [95% CI -2.28, -0.65]; I 2 = 91.6%), and quality of life (SMD 1.02 [95% CI 0.30, 1.74]; I 2 = 83.2%). Physical activity did not change at 6 months, and a small to moderate improvement was found at 12 months postsurgery, despite large improvements in quality of life, pain, and physical function. Reasons for the lack of increased PA are unknown but may be behavioral in nature, as a sedentary lifestyle is difficult to change. Changing sedentary behavior should be a future focus of research in this subgroup. © 2017, American College of Rheumatology.
Short-term clinical experience with hip resurfacing arthroplasty.
Cieliński, Łukasz; Kusz, Damian; Wojciechowski, Piotr; Dziuba, Anna
2007-01-01
This paper discusses the authors' experience with hip resurfacing arthroplasty. Although introduced many years ago, the method did not gain wide popularity because of poor long-term outcomes. At present, owing to the introduction of metal-on-metal bearings and hybrid fixation techniques, short- and mid-term results are very good and encourage wider use of this technique, especially in the younger and more active patients whose results with standard total hip replacements would be unsatisfactory. We performed 13 hip resurfacing arthroplasties at our institution between August 1, 2005, and May 1, 2006. Twelve patients reported for the scheduled follow-up and were included in the study. Treatment outcomes were assessed according to the Harris Hip Score. The short-term outcomes of hip resurfacing arthroplasties are encouraging. In the study group there were no intraoperative complications, infections, peripheral nerve palsy, hip dislocations or clinically overt vein thrombosis. All of the patients reported complete or major pain relief. Clinical assessment according to the Harris Hip Score revealed improvement from an average of 57.7 (20.1) points preoperatively to an average of 87.7 (12) points after the surgery. Crutches were used for a maximum of 6 weeks postoperatively. All of the patients are currently able to walk without crutches with full weight-bearing. 1) Hip resurfacing arthroplasty seems to be an advisable method of operative management of younger, active patients, in whom standard THR would be associated with a high risk of failure; it allows THR to be postponed and carried out as a revision surgery with the acetabular component already in place. 2) Despite the good short- and mid-term results, the utility of this method should be evaluated with caution due to the lack of adequate long-term follow-up data.
Metal-on-metal hip joint tribology.
Dowson, D; Jin, Z M
2006-02-01
The basic tribological features of metal-on-metal total hip replacements have been reviewed to facilitate an understanding of the engineering science underpinning the renaissance of these hard-on-hard joints. Metal-on-polymer hip replacements operate in the boundary lubrication regime, thus leading to the design guidance to reduce the femoral head diameter as much as is feasible to minimize frictional torque and volumetric wear. This explains why the gold-standard implant of this form from the past half-century had a diameter of only 22.225 mm (7/8 in). Metal-on-metal implants can operate in the mild mixed lubrication regime in which much of the applied load is supported by elastohydrodynamic films. Correct tribological design leads to remarkably low steady state wear rates. Promotion of the most effective elastohydrodynamic films calls for the largest possible head diameters and the smallest clearances that can reasonably be adopted, consistent with fine surface finishes, good sphericity and minimal structural elastic deformation of the cup on its foundations. This guidance, which is opposite in form to that developed for metal-on-polymer joints, is equally valid for solid (monolithic) metallic heads on metallic femoral stems and surface replacement femoral shells. Laboratory measurements of friction and wear in metal-on-metal joints have confirmed their potential to achieve a very mild form of mixed lubrication. The key lies in the generation of effective elastohydrodynamic lubricating films of adequate thickness compared with the composite roughness of the head and cup. The calculation of the film thickness is by no means easy, but the full procedure is outlined and the use of an empirical formula that displays good agreement with calculations based upon the full numerical solutions is explained. The representation of the lambda ratio, lambda, embracing both film thickness and composite roughness, is described.
Delirium Research: Where Am I?
... facility, he experienced shortness of breath and acute lower-extremity edema that resulted in a series of hospital ... had a serious fall and sustained multiple hip fractures that required emergency hip replacement surgery to repair. ...
Cell therapy of hip osteonecrosis with autologous bone marrow grafting.
Hernigou, Philippe; Poignard, Alexandre; Zilber, Sebastien; Rouard, Hélène
2009-01-01
One of the reasons for bone remodeling leading to an insufficient creeping substitution after osteonecrosis in the femoral head may be the small number of progenitor cells in the proximal femur and the trochanteric region. Because of this lack of progenitor cells, treatment modalities should stimulate and guide bone remodeling to sufficient creeping substitution to preserve the integrity of the femoral head. Core decompression with bone graft is used frequently in the treatment of osteonecrosis of the femoral head. In the current series, grafting was done with autologous bone marrow obtained from the iliac crest of patients operated on for early stages of osteonecrosis of the hip before collapse with the hypothesis that before stage of subchondral collapse, increasing the number of progenitor cells in the proximal femur will stimulate bone remodeling and creeping substitution and thereby improve functional outcome. Between 1990 and 2000, 342 patients (534 hips) with avascular osteonecrosis at early stages (Stages I and II) were treated with core decompression and autologous bone marrow grafting obtained from the iliac crest of patients operated on for osteonecrosis of the hip. The percentage of hips affected by osteonecrosis in this series of 534 hips was 19% in patients taking corticosteroids, 28% in patients with excessive alcohol intake, and 31% in patients with sickle cell disease. The mean age of the patients at the time of decompression and autologous bone marrow grafting was 39 years (range: 16-61 years). The aspirated marrow was reduced in volume by concentration and injected into the femoral head after core decompression with a small trocar. To measure the number of progenitor cells transplanted, the fibroblast colony forming unit was used as an indicator of the stroma cell activity. Patients were followed up from 8 to 18 years. The outcome was determined by the changes in the Harris hip score, progression in radiographic stages, change in volume determined by digitizing area of the necrosis on the different cuts obtained on MRI, and by the need for hip replacement. Total hip replacement was necessary in 94 hips (evolution to collapse) among the 534 hips operated before collapse (Stages I and II). Sixty-nine hips with stage I osteonecrosis of the femoral head at the time of surgery demonstrated total resolution of osteonecrosis based on preoperative and postoperative MRI studies; these hips did not show any changes on plain radiographs. Before treatment, these 69 osteonecrosis had only a marginal band like pattern as abnormal signal and a volume less than 20 cubic centimeters. The intralesional area had kept a normal signal as regards the signal of the femoral head outside the osteonecrosis area. For the 371 other hips without collapse at the most recent follow up (average 12 years), the mean preoperative volume of the osteonecrosis was 26 cm(3) (minimum 12, maximum 30 cm(3)). The mean volume of the abnormal signal measured on MRI at the most recent follow up (mean 12 years) was 12 cm(3). The abnormal signal persisting as a sequelae was seen on T1 images as an intralesional area of low intensity signal with a disappearance of the marginal band like pattern. According to our experience, best indication for the procedure is symptomatic hips with osteonecrosis without collapse. In some patients who had Steinberg stage III osteonecrosis (subchondral lucency, no collapse) successful outcomes (no further surgery) has been obtained between 5 to 10 years. Therefore in selected patients, even more advanced disease can be considered for core decompression. Patients who had the greater number of progenitor cells transplanted in their hips had better outcomes.
Lungu, Eugen; Vendittoli, Pascal-André; Desmeules, François
2015-10-05
The ability to predict preoperatively the identity of patients undergoing hip arthroplasty at risk of suboptimal outcomes could help implement interventions targeted at improving surgical results. The objective was to develop a preliminary prediction algorithm (PA) allowing the identification of patients at risk of unsatisfactory outcomes one to two years following hip arthroplasty. Retrospective data on a cohort of 265 patients having undergone primary unilateral hip replacement (188 total arthroplasties and 77 resurfacing arthroplasties) from 2004 to 2010 were collected from our arthroplasty database. Hip pain and function, as measured by the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) were collected, as well as self-reported hip joint perception after surgery. Demographic and clinical variables recorded at the time of the surgery were considered as potential predictors. Patients were considered as having a suboptimal surgical outcome if they were in the worst quartile of the postoperative total WOMAC score and perceived their operated hip as artificial with minimal or major limitations. The PA was developed using recursive partitioning. Mean postoperative surgical follow-up was 446 ± 171 days. Forty patients (15.1 %) had a postoperative total WOMAC score in the worst quartile (>11.5/100) and perceived their joint as artificial with minimal or major restrictions. A PA consisting of the following variables achieved the most acceptable level of prediction: gender, age at the time of surgery, body mass index (BMI), and three items of the preoperative WOMAC (degree of pain with walking on a flat surface and during the night as well as degree of difficulty with putting socks or stockings). The rule had a sensitivity of 75.0 % (95 % CI: 59.8-85.8), a specificity of 77.8 % (95 % CI: 71.9-82.7), a positive predictive value of 37.5 % (95 % CI: 27.7-48.5), a negative predictive value of 94.6 % (95 % CI: 90.3-97.0) and positive and negative likelihood ratios of 3.38 (95 % CI: 2.49-4.57) and 0.34 (95 % CI: 0.19-0.55) respectively. The preliminary PA shows promising results at identifying patients at risk of significant functional limitations, increased pain and inadequate joint perception after hip arthroplasty. Clinical use should not be implemented before additional validation and refining.
Reflor, H J; Wirth, C J; Schreiner, B
1979-10-01
30 patients whose total endoprosthesis of the hip joint had been removed without any replacement, thus creating a so-called state of secondary resection, were followed up 6 months to 6 years after the operation. It was found that in almost two-thirds of the cases a subjective feeling of improved mobility was reported. The objective findings consisted in restrictions of the total rotation, abduction and adduction of 1/3 rd of the normal extent of mobility. An average value of 74.7 degrees was recorded for flexion. 28 patients stated that their walking performance was satisfactory to very good when using a walking-stick as support. More than three-quarters of the patients questioned stated their pain had been positively influenced by the creation of the state of secondary resection. Another objective finding was a difference between the length of the legs amounting to 4.2 cm on the average. We could prove the existence of a relationship between the difference in leg length and the roentgenologically visualised supporting of the resection area of the coxal end of the femur at the lateral pelvis. Since all the patients with the exception of two could resume their customary daily routine activities, the state of secondary resection after unsuccessful total endoprosthesis of the hip joint must be considered a reasonably acceptable alternative.
Zhang, Pei; Liang, Yuan; Chen, Pengtao; Fang, Yongchao; He, Jinshan; Wang, Jingcheng
2017-02-21
The use of intravenous (IV) or topical tranexamic acid (TXA) in total hip arthroplasty has been proven to be effective and safe in total hip arthroplasty. However, which of these two administration routes is better has not been determined. The combined administration of TXA has been used in total knee arthroplasty with satisfactory results. We hypothesized that combined application of TXA may be the most effective way without increased rate of thrombotic events such as deep vein thrombosis (DVT) and pulmonary embolisms (PE) in patients subjected to primary total hip replacement (THA). A meta-analysis was conducted to compare the efficacy and safety of the combined use of tranexamic acid (TXA) relative to topical or intravenous (IV) use alone for treatment of primary THA. The outcomes included total blood loss, postoperative hemoglobin decline, transfusion rates, and the incidence rates of deep vein thrombosis (DVT) and pulmonary embolisms (PE). We searched electronic databases including PubMed, EMBASE, the Cochrane Library, Web of Science, the Chinese Biomedical Literature database, the CNKI database, and Wanfang Data until September 2016. The references of the included articles were also checked for additional potentially relevant studies. There were no language restrictions for the search. The data of the included studies were analyzed using RevMan 5.3 software. Seven studies met the inclusion criteria, encompassing a total of 1762 patients. Our meta-analysis demonstrated that total blood loss, postoperative hemoglobin decline, and transfusion rates were significantly lower for patients that received the combined treatment compared to patients that received either topical or intravenous administration of TXA. No statistical differences were found in the incidence of deep venous thrombosis (DVT) or pulmonary embolism (PE). The group that received the combined treatment had lower total blood loss, postoperative hemoglobin decline, and transfusion rates without an increased rate of thrombotic events (DVT or PE). The topical or intravenous use of TXA in primary THA is generally considered to be safe and effective. This meta-analysis demonstrated that combined TXA application may be superior to topical or intravenous application of TXA alone. However, larger, high-quality randomized control trials are required for greater confidence in this finding.
Middleton, Addie; Kuo, Yong-Fang; Graham, James E; Karmarkar, Amol; Lin, Yu-Li; Goodwin, James S; Haas, Allen; Ottenbacher, Kenneth J
2018-04-21
Examine readmission patterns over 90-day episodes of care in persons discharged from hospitals to post-acute settings. Retrospective cohort study. Acute care hospitals. Medicare fee-for-service enrollees (N = 686,877) discharged from hospitals to post-acute care in 2013-2014. The cohort included beneficiaries >65 years of age hospitalized for stroke, joint replacement, or hip fracture and who survived for 90 days following discharge. 90-day unplanned readmissions. The cohort included 127,680 individuals with stroke, 442,195 undergoing joint replacement, and 117,002 with hip fracture. Thirty-day readmission rates ranged from 3.1% for knee replacement patients discharged to home health agencies (HHAs) to 14.4% for hemorrhagic stroke patients discharged to skilled nursing facilities (SNFs). Ninety-day readmission rates ranged from 5.0% for knee replacement patients discharged to HHAs to 26.1% for hemorrhagic stroke patients discharged to SNFs. Differences in readmission rates decreased between stroke subconditions (hemorrhagic and ischemic) and increased between joint replacement subconditions (knee, elective hip, and nonelective hip) from 30 to 90 days across all initial post-acute discharge settings. We observed clear patterns in readmissions over 90-day episodes of care across post-acute discharge settings and subconditions. Our findings suggest that patients with hemorrhagic stroke may be more vulnerable than those with ischemic over the first 30 days after hospital discharge. For patients receiving nonelective joint replacements, readmission prevention efforts should start immediately after discharge and continue, or even increase, over the 90-day episode of care. Copyright © 2018 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.
Health literacy and surgery expectations in total hip and knee arthroplasty patients.
Hadden, Kristie B; Prince, Latrina Y; Bushmiaer, Marty K; Watson, Jamie C; Barnes, C Lowry
2018-05-28
This study assessed patients' health literacy and expectations for total hip (THA) and total knee (TKA) replacement surgery, and compared health literacy levels of patients and their caregivers. A convenience sample of 200 THA/TKA participants, patients and their caregivers, participated in this study. Results demonstrated no statistical difference in health literacy between patients and their caregivers. However, patients with lower health literacy had significantly lower expectations for walking after surgery. Practices should be aware that caregivers may not be any better equipped to consume and use complicated patient education materials than the patient they are assisting. Additionally, lower health literacy, rather than or in addition to race or social factors, may contribute to disparities in opting for THA/TKA because of lower expectations for walking after surgery. Healthcare practices should develop patient educational materials that are easy for all patients and caregivers to understand, especially those with low health literacy. Additional patient education and counseling may help patients with low health literacy realistically align their expectations and mitigate barriers to consenting to surgery due to low expectations. Copyright © 2018 Elsevier B.V. All rights reserved.
Huber, J; Dabis, E; Zumstein, M D; Hüsler, J
2013-06-01
The outcome of orthopaedic surgery such as total hip replacement (THR) or total knee replacement (TKR) is commonly given by the change in mean scores on patient-reported outcome measures (Prom's). This may give the impression that all enrolled patients have experienced an improvement. But the Swedish hip registry and other studies report a reduction of complaints in 80-85 % of patients ("responders"), with the remainder (approximately one in six) remaining unchanged or reporting worse complaints ("non-responders"). According to Cohen, the degree of success in the "responders" group can be subdivided into excellent, good and moderate. For a given treatment, a total of 5 different outcome groups can therefore be defined: excellent, good, moderate, unchanged and worse. Allocation to the groups is based on the "relative effect per patient" (REPP). The REPP is calculated as the base-line score minus the post-treatment score divided by the baseline score. The maximum possible REPP is 1; a REPP of 0 means no effect and a negative REPP means deterioration. Allocation to the outcome groups is as follows: excellent 0.95 to 1 REPP, good 0.5 to 0.95 REPP, moderate over 0.2 to 0.5 REPP, unchanged -0.2 to 0.2 REPP and worse below -0.2 REPP. Our local arthroplasty register was used to evaluate the 1-year outcomes of THR and TKR patients operated between March 2003 and November 2008, using WOMAC scores and EuroQoL scores. Only patients with complete data sets and unilateral THR/TKR were included. The success rate given by the REPP method was compared with that of the "responder rate" method defined by the OMERACT-OARSI criteria. With the WOMAC questionnaire, outcomes were as follows (THR/TKR): excellent 29/14 %, good 51/54 %, moderate 11/13 %, unchanged at 5/12 %, worse 4/7 %. The corresponding values for the EuroQoL were (THR/TKR): excellent 16/6 %, good 41/42 %, moderate 25/28 %, unchanged 12/16 %, worse 6/8 %. For THR, success rates were 92 % using the "responder rate" method (OMERACT-OARSI criteria) and 91 % using the REPP method with the WOMAC. Calculation of the REPP and the subsequent allocation to outcome groups is simple. The distribution of outcomes depends on the intervention (THR results better than TKR) and the patient questionnaire used (better results with a condition-specific than a generic questionnaire). The proportion of "unchanged" and "moderate" outcomes was greater with the generic questionnaire than with the condition-specific questionnaire, while the proportion of "worse" outcomes was similar for the two instruments. Partitioning of the degree of success into sub-groups, based on the REPP, provides more information for both the patient and the orthopaedic surgeon. Georg Thieme Verlag KG Stuttgart · New York.
Langton, David John; Sidaginamale, Raghavendra Prasad; Avery, Peter; Waller, Sue; Tank, Ghanshyabhai; Lord, James; Joyce, Thomas; Cooke, Nick; Logishetty, Raj; Nargol, Antoni Viraf Francis
2016-01-01
Objectives To determine risk factors for revision in patients implanted with a commonly used metal on metal (MoM) hip replacement. Design Retrospective cohort study in combination with a prospective national retrieval study (Northern Retrieval Registry (NRR)). Setting Combined orthopaedic unit in combination with the NRR. Participants All patients implanted with a DePuy Pinnacle MoM hip prostheses by the 2 senior authors were invited to attend for a review which included clinical examination, blood metal ion measurements, radiographs and targeted imaging. Explanted components underwent wear analysis using validated methodology and these results were compared with those obtained from the NRR. Results 489 MoM Pinnacle hips were implanted into 434 patients (243 females and 191 males). Of these, 352 patients attended the MoM recall clinics. 64 patients had died during the study period. For the purposes of survival analysis, non-attendees were assumed to have well-functioning prostheses. The mean follow-up of the cohort as a whole was 89 months. 71 hips were revised. Prosthetic survival for the whole cohort was 83.6% (79.9–87.3) at 9 years. The majority of explanted devices exhibited signs of taper junction failure. Risk factors for revision were bilateral MoM prostheses, smaller Pinnacle liners, and implantation in 2006 and later years. A significant number of devices were found to be manufactured out of their specifications. This was confirmed with analysis of the wider data set from the NRR. Conclusions This device was found to have an unacceptably high revision rate. Bilateral prostheses, those implanted into female patients and devices implanted in later years were found to be at greater risk. A significant number of explanted components were found to be manufactured with bearing diameters outside of the manufacturer's stated tolerances. Our findings highlight the clinical importance of hitherto unrecognised variations in device production. PMID:27130159
Johnson, Aaron J; Naziri, Qais; Hooper, Hasan A; Mont, Michael A
2012-04-04
The sensitivity of airport security screening measures has increased substantially during the past decade, but few reports have examined how this affects patients who have undergone hip arthroplasty. The purpose of this study was to determine the experiences of patients who had hip prostheses and who passed through airport security screenings. A consecutive series of 250 patients who presented to the office of a high-volume surgeon were asked whether they had had a hip prosthesis for at least one year and, if so, whether they had flown on a commercial airline within the past year. Patients who responded affirmatively to both questions were asked to complete a written survey that included questions about which joint(s) had been replaced, the number of encounters with airport security, the frequency and location of metal detector activation, any additional screening procedures that were utilized, whether security officials requested documentation regarding the prosthesis, the degree of inconvenience, and other relevant information. Of the 143 patients with hip replacements who traveled by air, 120 (84%) reported triggering the alarm and required wanding with a handheld detector. Twenty-five of these patients reported subsequently having to undergo further inspection, including additional wanding, being patted down, and in two cases having to undress in a private room to show the incision. Ninety-nine (69%) of the 143 patients reported that the prosthetic joint caused an inconvenience while traveling. This study provides interesting and critical information that allows physicians to understand the real-world implications of implanted orthopaedic devices for patients who are traveling where there has been heightened security since September 11, 2001. Patients should be counseled that they should expect delays and be prepared for such inconveniences, but that these are often only momentary. This information could relieve some anxiety and concerns that patients may have prior to traveling.
Wittig-Wells, Deborah; Higgins, Melinda; Davis, Erica; Johnson, Ifeya; Louis, Latalya; Mason, Olga; Samms-McPherson, Jacqueline; Sims, Sandra; Jacob, Ani
2015-01-01
Patient education for the use and administration of aspirin (ASA) as an anticoagulant may be deficient. To pilot a knowledge assessment tool regarding the use of aspirin (ASA) as an anticoagulant and to evaluate the impact of a focused approach for discharge teaching. One-group pretest-posttest pilot study. Convenience sample of patients hospitalized for total knee and total hip arthroplasty. Researcher developed ASA quiz. Focused education on aspirin as an anticoagulant. There was a statistically significant improvement in knowledge (Wilcoxon rank sum test Z = 3.880, p < .001).
Judge, A; Batra, R N; Thomas, G E; Beard, D; Javaid, M K; Murray, D W; Dieppe, P A; Dreinhoefer, K E; Peter-Guenther, K; Field, R; Cooper, C; Arden, N K
2014-03-01
To describe whether body mass index (BMI) is a clinically meaningful predictor of patient reported outcomes following primary total hip replacement (THR) surgery. Combined data from prospective cohort studies. We obtained information from four cohorts of patients receiving primary THR for osteoarthritis: Exeter Primary Outcomes Study (EPOS) (n = 1431); EUROHIP (n = 1327); Elective Orthopaedic Centre (n = 2832); and St. Helier (n = 787). The exposure of interest was pre-operative BMI. Confounding variables included: age, sex, SF-36 mental health, comorbidities, fixed flexion, analgesic use, college education, OA in other joints, expectation of less pain, radiographic K&L grade, ASA grade, years of hip pain. The primary outcome was the Oxford Hip Score (OHS). Regression models describe the association of BMI on outcome adjusting for all confounders. For a 5-unit increase in BMI, the attained 12-month OHS decreases by 0.78 points 95%CI (0.27-1.28), P-value 0.001. Compared to people of normal BMI (20-25), those in the obese class II (BMI 35-40) would have a 12-month OHS that is 2.34 points lower. Although statistically significant this effect is small and not clinically meaningful in contrast to the substantial change in OHS seen across all BMI groupings. In obese class II patients achieved a 22.2 point change in OHS following surgery. Patients achieved substantial change in OHS after THR across all BMI categories, which greatly outweighs the small difference in attained post-operative score. The findings suggest BMI should not present a barrier to access THR in terms of PROMs. Copyright © 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Judge, Andy; Batra, Rajbir N; Thomas, Geraint; Beard, David; Javaid, M Kassim; Murray, David; Dieppe, Paul A; Dreinhoefer, Karsten; Peter-Guenther, Klaus; Field, Richard; Cooper, Cyrus; Arden, Nigel K
2014-01-01
Objectives To describe whether body mass index (BMI) is a clinically meaningful predictor of patient reported outcomes following primary total hip replacement (THR) surgery Design Combined data from prospective cohort studies. We obtained information from four cohorts of patients receiving primary THR for osteoarthritis: Exeter Primary Outcomes Study (n=1431); EUROHIP (n=1327); Elective Orthopaedic Centre (n=2832); and St. Helier (n=787). The exposure of interest was pre-operative BMI. Confounding variables included: age, sex, SF-36 mental health, comorbidities, fixed flexion, analgesic use, college education, OA in other joints, expectation of less pain, radiographic K&L grade, ASA grade, years of hip pain. The primary outcome was the Oxford Hip Score (OHS). Regression models describe the association of BMI on outcome adjusting for all confounders. Results For a 5-unit increase in BMI, the attained 12-month OHS decreases by 0.78 points 95%CI (0.27 to 1.28), p-value 0.001. Compared to people of normal BMI (20 to 25), those in the obese class II (BMI 35 to 40) would have a 12-month OHS that is 2.34 points lower. Although statistically significant this effect is small and not clinically meaningful in contrast to the substantial change in OHS seen across all BMI groupings. In obese class II patients achieved a 22.2 point change in OHS following surgery. Conclusions Patients achieved substantial change in OHS after THR across all BMI categories, which greatly outweighs the small difference in attained post-operative score. The findings suggest BMI should not present a barrier to access THR in terms of PROMs. PMID:24418679
Quah, Conal; Porteous, Matthew; Stephen, Arthur
2017-05-01
The management of periprosthetic fractures around total hip replacements is a complex and challenging problem. Getting it right first time is an important factor in reducing the morbidity, mortality and financial burden associated with these injuries. Understanding and applying the basic principles of fracture management helps increase the chance of successful treatment. Based on these principles, we suggest a treatment algorithm for managing periprosthetic fractures around polished tapered femoral stems.
Hoornenborg, Daniel; Sierevelt, Inger N; Spuijbroek, Joost A; Cheung, John; van der Vis, Harm M; Beimers, Lijkele; Haverkamp, Daniel
2017-09-11
An ongoing discussion is whether using a hydroxyapatite coating enhances the ingrowth and longevity of a femoral stem in total hip arthroplasty. The best way to predict speed of ingrowth and long-term outcome is by evaluating micromotion by radiostereometric analysis. To study the effect of hydroxyapatite (HA) coating on the migration of the SL-PLUS hip stem, we performed a prospective double blind randomised controlled trial comparing the early migration of the hydroxyapatite (HA)-coated SL-PLUS stem compared to the Standard (non-coated) SL-PLUS stem. 51 patients were randomly assigned to receive either an uncoated or a HA-coated femoral component during total hip replacement. RSA images were obtained direct postoperatively and at 6 weeks, 12 weeks, 6 months, 12 months and 24 months. HOOS scores were obtained preoperative and at final follow-up. RSA evaluation demonstrated significant migration up to 3 months postoperatively in both groups. After initial setting no significant migration was observed. There was no significant difference in migration between the HA-coated group and the uncoated group.Both Harris Hip Score (HHS) and HOOS domain scores (pain and ADL) significantly improved compared to baseline at 24 months after surgery in both treatment groups (p<0.001 for all comparisons). Improvement did not differ significantly between the 2 groups. At 2 years follow-up, the HA-coated and uncoated Zweymuller type, distal fitting stem do not show different migration patterns.
Avascular necrosis after chemotherapy for haematological malignancy in childhood.
Salem, K H; Brockert, A-K; Mertens, R; Drescher, W
2013-12-01
Avascular necrosis (AVN) is a serious complication of high-dose chemotherapy for haematological malignancy in childhood. In order to describe its incidence and main risk factors and to evaluate the current treatment options, we reviewed 105 children with a mean age of 8.25 years (1 to 17.8) who had acute lymphoblastic or acute myeloid leukaemia, or a non-Hodgkin's lymphoma. Overall, eight children (7.6%) developed AVN after a mean of 16.8 months (8 to 49). There were four boys and four girls with a mean age of 14.4 years (9.8 to 16.8) and a total of 18 involved sites, 12 of which were in the femoral head. All these children were aged > nine years (p < 0.001). All had received steroid treatment with a mean cumulative dose of prednisone of 5967 mg (4425 to 9599) compared with a mean of 3943 mg (0 to 18 585) for patients without AVN (p = 0.005). No difference existed between genders and no thrombophilic disorders were identified. Their initial treatment included 11 core decompressions and two bipolar hip replacements. Later, two salvage osteotomies were done and three patients (four hips) eventually needed a total joint replacement. We conclude that AVN mostly affects the weight-bearing epiphyses. Its risk increases with age and higher steroid doses. These high-risk patients may benefit from early screening for AVN.
Müller, Daniel A; Zingg, Patrick O; Dora, Claudio
2014-01-01
Opponents associate minimally invasive total hip replacement (THR) with additional risks, potentially resulting in increased implant failure rates. The purpose was to document complications, quality of implant positioning and five-year survivorship of THR using the AMIS approach and to test the hypothesis that eventual high complication and revision rates would be limited to an early series and be avoided by junior surgeons who get trained by a senior surgeon. A consecutive series of 150 primary THR implanted during the introduction of the AMIS technique in the department was retrospectively analysed for complications, implant positioning and implant survival after a minimum of five years. Survivorship curves of implants were compared between different surgeons and time periods. Due to implant revision for any reason the five-year survival rate was 94.6%, 78.9% for the first 20 and 96.8% for the following 130 AMIS procedures (p = 0.001). The hazard ratio for implant failure was 0.979 indicating a risk reduction of 2% every further case. The five-year implant survivorship of those procedures performed by two junior surgeons was 97.7%. We conclude that adoption of AMIS temporarily exposed patients to a higher risk of implant revisions, which normalised after the first 20 cases and that experience from a single surgeon's learning curve could effectively be taught to junior surgeons.
El-Hajj Fuleihan, Ghada; Nabulsi, Mona; Tamim, Hala; Maalouf, Joyce; Salamoun, Mariana; Khalife, Hassan; Choucair, Mahmoud; Arabi, Asma; Vieth, Reinhold
2006-02-01
Despite the high prevalence of hypovitaminosis D in children and adolescents worldwide, the impact of vitamin D deficiency on skeletal health is unclear. One hundred seventy-nine girls, ages 10-17 yr, were randomly assigned to receive weekly oral vitamin D doses of 1,400 IU (equivalent to 200 IU/d) or 14,000 IU (equivalent to 2,000 IU/d) in a double-blind, placebo-controlled, 1-yr protocol. Areal bone mineral density (BMD) and bone mineral content (BMC) at the lumbar spine, hip, forearm, total body, and body composition were measured at baseline and 1 yr. Serum calcium, phosphorus, alkaline phosphatase, and vitamin D metabolites were measured during the study. In the overall group of girls, lean mass increased significantly in both treatment groups (P < or = 0.05); bone area and total hip BMC increased in the high-dose group (P < 0.02). In premenarcheal girls, lean mass increased significantly in both treatment groups, and there were consistent trends for increments in BMD and/or BMC at several skeletal sites, reaching significance at lumbar spine BMD in the low-dose group and at the trochanter BMC in both treatment groups. There was no significant change in lean mass, BMD, or BMC in postmenarcheal girls. Vitamin D replacement had a positive impact on musculoskeletal parameters in girls, especially during the premenarcheal period.
Villadsen, Allan; Overgaard, Søren; Holsgaard-Larsen, Anders; Christensen, Robin; Roos, Ewa M
2014-07-01
Knowledge about the effects of exercise in severe and endstage osteoarthritis (OA) is limited. The aim was to evaluate the efficacy of a neuromuscular exercise program in patients with clinically severe hip or knee OA. This was a randomized controlled assessor-blinded trial. Patients received an educational package (care-as-usual) only, or care-as-usual plus an 8-week neuromuscular exercise intervention (NEMEX-TJR). NEMEX-TJR was supervised by a physiotherapist, twice weekly for 1 h. The primary outcome was Activities of Daily Living (ADL) subscale from the Hip disability and Osteoarthritis Outcome Score (HOOS) and the Knee Injury and Osteoarthritis Outcome Score (KOOS) questionnaire. The secondary outcomes were the HOOS/KOOS subscales Pain, Symptoms, Sport and Recreation, and Joint-related Quality of Life. Exploratory outcomes were functional performance measures and lower limb muscle power. Included were 165 patients, 56% female, average age 67 years (SD ± 8), and a body mass index of 30 (SD ± 5), who were scheduled for primary hip or knee replacement. The postintervention difference between mean changes in ADL was 7.2 points (95% CI 3.5 to 10.9, p = 0.0002) in favor of NEMEX-TJR compared with control. Second, there were statistically significant differences between groups in favor of NEMEX-TJR on all self-reported outcomes and most functional performance tests (walk, chair stands, and 1-leg knee bends). Stratified analyses according to joint revealed moderate effect size for ADL for hip patients (0.63, 95% CI 0.26 to 1.00). Corresponding effect size for knee patients was small (0.23 95% CI -0.14 to 0.60). Feasibility of neuromuscular exercise was confirmed in patients about to have total joint replacement. Self-reported activities of daily living and objective performance were improved and pain reduced immediately following 8 weeks of neuromuscular exercise. While the effects were moderate in hip OA, they were only small in knee OA. ClinicalTrials.gov Identifier: NCT01003756.
Yan, Yu; Dowson, Duncan; Neville, Anne
2013-02-01
The second generation Metal-on-Metal (MoM) hip replacements have been considered as an alternative to commonly used Polyethylene-on-Metal (PoM) joint prostheses due to polyethylene wear debris induced osteolysis. However, the role of corrosion and the biofilm formed under tribological contact are still not fully understood. Enhanced metal ion concentrations have been reported widely from hair, blood and urine samples of patients who received metal hip replacements and in isolated cases when abnormally high levels have caused adverse local tissue reactions. An understanding of the origin of metal ions is really important in order to design alloys for reduced ion release. Reciprocating pin-on-plate wear tester is a standard instrument to assess the interaction of corrosion and wear. However, more realistic hip simulator can provide a better understanding of tribocorrosion process for hip implants. It is very important to instrument the conventional hip simulator to enable electrochemical measurements. In this study, simple reciprocating pin-on-plate wear tests and hip simulator tests were compared. It was found that metal ions originated from two sources: (a) a depassivation of the contacting surfaces due to tribology (rubbing) and (b) corrosion of nano-sized wear particles generated from the contacting surfaces. Copyright © 2012 Elsevier Ltd. All rights reserved.
Patient-Reported Outcomes of Periacetabular Osteotomy from the Prospective ANCHOR Cohort Study
Clohisy, John C.; Ackerman, Jeffrey; Baca, Geneva; Baty, Jack; Beaulé, Paul E.; Kim, Young-Jo; Millis, Michael B.; Podeszwa, David A.; Schoenecker, Perry L.; Sierra, Rafael J.; Sink, Ernest L.; Sucato, Daniel J.; Trousdale, Robert T.; Zaltz, Ira
2017-01-01
Background: Current literature describing the periacetabular osteotomy (PAO) is mostly limited to retrospective case series. Larger, prospective cohort studies are needed to provide better clinical evidence regarding this procedure. The goals of the current study were to (1) report minimum 2-year patient-reported outcomes (pain, hip function, activity, overall health, and quality of life), (2) investigate preoperative clinical and disease characteristics as predictors of clinical outcomes, and (3) report the rate of early failures and reoperations in patients undergoing contemporary PAO surgery. Methods: A large, prospective, multicenter cohort of PAO procedures was established, and outcomes at a minimum of 2 years were analyzed. A total of 391 hips were included for analysis (79% of the patients were female, and the average patient age was 25.4 years). Patient-reported outcomes, conversion to total hip replacement, reoperations, and major complications were documented. Variables with a p value of ≤0.10 in the univariate linear regressions were included in the multivariate linear regression. The backward stepwise selection method was used to determine the final risk factors of clinical outcomes. Results: Clinical outcome analysis demonstrated major clinically important improvements in pain, function, quality of life, overall health, and activity level. Increasing age and a body mass index status of overweight or obese were predictive of improved results for certain outcome metrics. Male sex and mild acetabular dysplasia were predictive of lesser improvements in certain outcome measures. Three (0.8%) of the hips underwent early conversion to total hip arthroplasty, 12 (3%) required reoperation, and 26 (7%) experienced a major complication. Conclusions: This large, prospective cohort study demonstrated the clinical success of contemporary PAO surgery for the treatment of symptomatic acetabular dysplasia. Patient and disease characteristics demonstrated predictive value that should be considered in surgical decision-making. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. PMID:28060231
Increased anteversion of press-fit femoral stems compared with anatomic femur.
Emerson, Roger H
2012-02-01
With contemporary canal-filling press-fit stems, there is no adjustability of stem position in the canal and therefore the canal anatomy determines stem version. Stem version will affect head/neck impingement, polyethylene wear from edge loading, and hip stability, but despite this, the postoperative version of a canal-filling press-fit stem is unclear. Is there a difference between the version of the nonoperated femur and the final version of a canal-filling press-fit femoral component? Could a difference create an alignment problem for the hip replacement? Sixty-four hips were studied with fluoroscopy and 46 nonarthritic and 41 arthritic hips were studied with MRI. A standardized fluoroscopic technique for determining preoperative and postoperative femoral version was developed with the patient supine on a fracture table undergoing supine total hip arthroplasty. To validate the methods, the results were compared with two selected series of axial MRI views of the hip comparing the version of the head with the version of the canal at the base of the neck. For the operated hips, the mean anatomic hip version was less than the stem version: 18.9° versus 27.0°. The difference on average was 8.1° of increased anteversion (SD, 7.4°). Both MRI series showed the femoral neck was more anteverted on average than the femoral head, thereby explaining the operative findings. With a canal-filling press-fit femoral component there is wide variation of postoperative component anteversion with most stems placed in increased anteversion compared with the anatomic head. The surgical technique may need to adjust for this if causing intraoperative impingement or instability.
Mulvaney, Sean W
2009-01-01
Viscosupplementation of the hip for symptomatic osteoarthritis appears to be safe and effective in more than 25 yr of use in Europe. More than 11 studies suggest that viscosupplementation in the hip is as effective as viscosupplementation in the knee. It appears to be a safe and reasonable alternative to nonsteroidal antiinflammatory drugs or intra-articular steroids for the treatment of osteoarthritis pain. Viscosupplementation in the hip may delay the need for hip replacement surgery. Viscosupplementation in the hip appears to work better in patients with fewer radiographic changes of osteoarthritis. Placement of viscosupplement in the hip under real-time ultrasound or fluoroscopic guidance is safe and well tolerated. Hip joint communication with the iliopsoas bursa may be a factor in studies of the effectiveness of viscosupplementation in the hip.
Olsen, Michael; Al Saied, Mohamed; Morison, Zachary; Sellan, Michael; Waddell, James P; Schemitsch, Emil H
2014-12-01
Mid-head resection short-stem hip arthroplasty is a conservative alternative to conventional total hip replacement and addresses proximal fixation challenges in patients not suitable for hip resurfacing. It is unclear whether proximal femoral morphology impacts the ultimate failure load of mid-head resection implanted femurs, thus the aim of this study was to investigate the effect of native neck-shaft angle (NSA) and coronal implant alignment on proximal femoral strength. In total, 36 synthetic femurs with two different proximal femoral morphologies were utilized in this study. Of them, 18 femurs with a varus NSA of 120° and 18 femurs with a valgus NSA of 135° were each implanted with a mid-head resection prosthesis. Femurs within the two different femoral morphology groups were divided into three equal coronal implant alignment groups: 10° valgus, 10° varus or neutral alignment. Prepared femurs were tested for stiffness and to failure in axial compression. There was no significant difference in stiffness nor failure load between femurs implanted with valgus-, varus- or neutrally aligned implants in femurs with a NSA of 120° (p = 0.396, p = 0.111, respectively). Femurs implanted in valgus orientation were significantly stiffer and failed at significantly higher loads than those implanted in varus alignment in femurs with a NSA of 135° (p = 0.001, p = 0.007, respectively). A mid-head resection short-stem hip arthroplasty seems less sensitive to clinically relevant variations of coronal implant alignment and may be more forgiving upon implantation in some femoral morphologies, however, a relative valgus component alignment is recommended. © IMechE 2014.
Nistor, Dan-Viorel; Caterev, Sergiu; Bolboacă, Sorana-Daniela; Cosma, Dan; Lucaciu, Dan Osvald Gheorghe; Todor, Adrian
2017-11-01
We conducted this study to establish if the transition from a lateral approach (LA) to the direct anterior approach (DAA) for a low volume hip arthroplasty surgeon during the steep learning curve can be performed maintaining the muscle sparing approach of the DAA without increasing the complication rates. In this controlled, prospective, randomized clinical study we investigated 70 patients (35 DAA, 35 LA) with similar demographics that underwent a total hip arthroplasty. Assessment of the two approaches consisted of determining the invasiveness through serum markers for muscle damage (i.e. myoglobin, creatine kinase and lactate dehydrogenase), the operative parameters such as post-operative pain and rescue medication consumption, the component positioning and complication rates. Post-operative myoglobin levels were higher (p < 0.001) in the LA group (326.42 ± 84.91 ng/mL) as compared to the DAA group (242.80 ± 71.03 ng/mL), but with no differences regarding other biomarkers for muscle damage. Pain levels were overall lower in the DAA group, with a statistical and clinical difference during surgery day (p < 0.001) associated with lower (p < 0.001) rescue medication consumption (median 1 (1; 3) mg morphine vs. 3 (2; 4) mg morphine). Most patients in the LA group reported chronic post-operative pain throughout all three evaluated months, while the majority of patients in the DAA group reported no pain after week six. Component positioning did not differ significantly between groups and neither did complication rates. The DAA can be transitioned from the LA safely, without higher complication rates while maintaining its muscle spearing advantages when performed by a low volume hip arthroplasty surgeon.
Brewster, D H; Stockton, D L; Reekie, A; Ashcroft, G P; Howie, C R; Porter, D E; Black, R J
2013-05-14
Release and dispersion of particles arising from corrosion and wear of total hip arthroplasty (THA) components has raised concerns about a possible increased risk of cancer. Concerns have been heightened by a recent revival in the use of metal-on-metal (MoM) hip prostheses. From a linked database of hospital discharge, cancer registration, and mortality records, we selected a cohort of patients who underwent primary THA (1990-2009) or primary resurfacing arthroplasty (mainly 2000-2009) in Scotland, with follow-up to the end of 2010. Available operation codes did not enable us to distinguish MoM THAs. Indirectly standardised incidence ratios (SIRs) were calculated for selected cancers with standardisation for age, sex, deprivation, and calendar period. The study cohort included 71 990 patients yielding 547 001 person-years at risk (PYAR) and 13 946 cancers diagnosed during follow-up. For the total period of observation combined, the risks of all cancers (SIR: 1.05; 95% CI: confidence interval 1.04-1.07), prostate cancer (SIR: 1.07; 95% CI: 1.01-1.14), and multiple myeloma (SIR: 1.22; 95% CI: 1.06-1.41) were increased. These modest increases in risk emerged in the context of effectively multiple tests of statistical significance, and may reflect inadequate adjustment for confounding factors. For 1317 patients undergoing primary resurfacing arthroplasty between 2000 and 2009 (PYAR=5698), the SIR for all cancers (n=39) was 1.23 (95% CI: 0.87-1.68). In the context of previous research, these results do not suggest a major cause for concern. However, the duration of follow-up of patients receiving recently introduced, new-generation MoM prostheses is too short to rule out a genuinely increased risk of cancer entirely.
Atchabahian, Arthur; Schwartz, Gary; Hall, Charles B; Lajam, Claudette M; Andreae, Michael H
2015-08-13
Regional analgesia is more effective than conventional analgesia for controlling pain and may facilitate rehabilitation after large joint replacement in the short term. It remains unclear if regional anaesthesia improves functional outcomes after joint replacement beyond three months after surgery. To assess the effects of regional anaesthesia and analgesia on long-term functional outcomes 3, 6 and 12 months after elective major joint (knee, shoulder and hip) replacement surgery. We performed an electronic search of several databases (CENTRAL, MEDLINE, EMBASE, CINAHL), and handsearched reference lists and conference abstracts. We updated our search in June 2015. We included randomized controlled trials (RCTs) comparing regional analgesia versus conventional analgesia in patients undergoing total shoulder, hip or knee replacement. We included studies that reported a functional outcome with a follow-up of at least three months after surgery. We used standard methodological procedures expected by Cochrane. We contacted study authors for additional information. We included six studies with 350 participants followed for at least three months. All of these studies enrolled participants undergoing total knee replacement. Studies were at least partially blinded. Three studies had a high risk of performance bias and one a high risk of attrition bias, but the risk of bias was otherwise unclear or low.Only one study assessed joint function using a global score. Due to heterogeneity in outcome and reporting, we could only pool three out of six RCTs, with range of motion assessed at three months after surgery used as a surrogate for joint function. All studies had a high risk of detection bias. Using the random-effects model, there was no statistically significant difference between the experimental and control groups (mean difference 3.99 degrees, 95% confidence interval (CI) - 2.23 to 10.21; P value = 0.21, 3 studies, 140 participants, very low quality evidence).We did not perform further analyses because immediate adverse effects were not part of the explicit outcomes of any of these typically small studies, and long-term adverse events after regional anaesthesia are rare.None of the included studies elicited or reported long-term adverse effects like persistent nerve damage. More high-quality studies are needed to establish the effects of regional analgesia on function after major joint replacement, as well as on the risk of adverse events (falls).
K, Kandhari V; M, Desai M; S, Bava S; N, Wade R
2015-01-01
Chances of avascular necrosis of acetabulum are rare as it enjoys a rich blood supply. But cases of post - traumatic avascular necrosis of acetabulum following fracture of posterior column have been well documented. Importance of identifying and suspecting the avascular necrosis of acetabulum is essential in cases of failed fixation of fracture acetabulum, previously operated using extensile approach to acetabulum; either extended anterior ilio - femoral or tri - radiate approach. Such patients usually present with repeated deep bone infection or with early failure of fixation with aseptic loosening and migration of its components. We present a similar case. 40 years female presented with inadequately managed transverse fracture of left acetabulum done by anterior extended ilio-inguinal approach. The fixation failed. She presented 6 months later with painful hip. Cemented total hip replacement was performed with reconstruction of acetabulum by posterior column plating. Six months postoperatively patient presented with dislodgement of cup, pelvic discontinuity and sinus in the thigh. Two stage revision surgery was planned. First implant, removal; debridement and antibiotic spacer surgery was performed. At second stage of revision total hip replacement, patient had Paprosky grade IIIb defect in acetabulum. Spacer was removed through the posterior approach. Anterior approach was taken for anterior plating. Intra-operatively external iliac pulsations were found to be absent so procedure was abandoned after expert opinion. Postoperatively digital subtraction angiography demonstrated a chronic block in the external iliac artery and corona mortis was the only patent vascular channel providing vascular to the left lower limb. Thus, peripheral limb was stealing blood supply from the acetabulum to maintain perfusion. Patient was ultimately left with pelvic discontinuity, excision arthroplasty and pseudoarthrosis of the left hip. Avascular necrosis of acetabulum is a rare entity & often not recognized. One should be suspicious about diagnosis of avascular necrosis of acetabulum in select cases of failed acetabular fixation, previously operated via extensile anterior ilio - inguinal approach. Angiographic evaluation is essential in revision cases of failed acetabular fixation. Corona mortis (crown or circle of death) can sometimes act as a savior of limb.
Czarniecki, Marcin; Caglic, Iztok; Grist, James T; Gill, Andrew B; Lorenc, Kamil; Slough, Rhys A; Priest, Andrew N; Barrett, Tristan
2018-05-01
To compare image quality, artefact, and distortion in standard echo-planar imaging (EPI) with periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) for prostate magnetic resonance imaging (MRI) diffusion-weighted imaging (DWI) in patients with previous total hip replacement (THR). 21 male subjects with a clinical suspicion for, or known prostate cancer and previous THR were scanned at 1.5 T using a phased-array body coil. DWI was obtained using single-shot EPI and PROPELLER techniques using fat saturation (PROPELLER-DWI-FS), and without (PROPELLER-DWI-NFS). Image quality (the overall impression of diagnostic quality) was compared to T 2 -weighted (T2WI) imaging using a 5-point Likert scale, with diffusion sequences additionally scored for artefact and distortion according to a 4-point scale, with artefact defined as the amount of prostate affected and distortion as the degree of warping of the organ. The T2W and DW image volumes were compared to produce quantitative distortion maps. A two-sample Wilcoxon test compared the qualitative scores, with inter-reader variability calculated using Cohen's kappa. 21 patients were included in the study, with an average age of 70.4 years and PSA 9.2 ng/ml. Hip metalwork was present bilaterally in 3 patients, left-sided in 9, and right-sided in 9. PROPELLER-DWI-FS significantly improved image quality (p < 0.01) and reduced distortion (p < 0.01) when compared to standard EP-DWI. Artefact was not shown to be significantly improved. The last 5 patients in the study were additionally imaged with PROPELLER-DWI-NFS, which resulted in a significant reduction in artefact compared to EP-DWI (p < 0.05). Quantitative distortion was significantly lower compared to EP-DWI for both PROPELLER with fat saturation (p < 0.01) and without fat saturation (p < 0.01). PROPELLER-DWI demonstrates better image quality and decreases both artefact and distortion compared to conventional echo planar sequences in patients with hip metalwork. Copyright © 2018 Elsevier B.V. All rights reserved.
Schunck, Antje; Kronz, Andreas; Fischer, Cornelius; Buchhorn, Gottfried Hans
2016-02-01
In a previous failure analysis performed on femoral components of cemented total hip replacements, we determined high volumes of abraded bone cement. Here, we describe the topography of the polished surface of polymethyl methacrylate (PMMA) bone cement containing zirconia radiopacifier, analyzed by scanning electron microscopy and vertical scanning interferometry. Zirconia spikes protruded about 300nm from the PMMA matrix, with pits of former crystal deposition measuring about 400nm in depth. We deduced that the characteristically mulberry-shaped agglomerates of zirconia crystals are ground and truncated into flat surfaces and finally torn out of the PMMA matrix. Additionally, evaluation of in vitro PMMA-on-PMMA articulation confirmed that crystal agglomerations of zirconia were exposed to grain pullout, fatigue, and abrasion. In great quantities, micron-sized PMMA wear and zirconia nanoparticles accumulate in the cement-bone interface and capsular tissues, thereby contributing to osteolysis. Dissemination of nanoparticles to distant lymph nodes and organs of storage has been reported. As sufficient information is lacking, foreign body reactions to accumulated nanosized zirconia in places of long-term storage should be investigated. The production of wear particles of PMMA bone cement in the interface to joint replacement devices, presents a local challenge. The presence of zirconia particles results in frustrated digestion attempts by macrophages, liberation of inflammatory mediators, and necrosis leading to aseptic inflammation and osteolyses. Attempts to minimize wear of articulating joints reduced the attention to the deterioration of cement cuffs. We therefore investigated polished surfaces of retrieved cuffs to demonstrate their morphology and to measure surface roughness. Industrially admixed agglomerates of the radiopacifier are abraded to micron and nano-meter sized particles. The dissemination of zirconia particles in the reticulo-endothelial system to storage organs is a possible burden. Research to replace the actual contrast media by non-particulate material deserves more attention. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Rothwell, M P; Pearson, D; Hunter, J D; Mitchell, P A; Graham-Woollard, T; Goodwin, L; Dunn, G
2011-06-01
To determine if oral oxycodone (OOXY) could provide equivalent postoperative analgesia and a similar side-effect profile to i.v. patient-controlled morphine in patients undergoing elective primary total hip replacement (THR) under spinal anaesthesia. We studied 110 consecutive patients aged 60-85 yr. After operation, patients were randomly allocated to receive either oral controlled- and immediate-release OOXY or i.v. patient-controlled analgesia (IVPCA) with morphine. Both groups received regular co-analgesia and antiemetics. The primary outcome measures were: (i) postoperative pain at rest and movement and (ii) nausea score recorded 12 hourly. The secondary outcome measures were: (i) time to first mobilization, (ii) total amount of opioid consumed, (iii) number of additional antiemetic doses, and (iv) time to analgesic discontinuation. There were no statistically significant differences in the primary outcome measures of pain at rest and movement (P>0.05, 95% confidence intervals -0.41, +0.96) or nausea score (P>0.5). The secondary outcome measures showed no significant difference in the total amount of opioid consumed (102 vs 63 mg; P>0.05) or time to mobilization (24.45 vs 26.6 h, P=0.2). The number of antiemetic doses required in the first 24 h was significantly lower in the OOXY group (1.1 vs 1.4, P<0.05). The time to analgesic discontinuation was significantly shorter in the OOXY group (50.5 vs 56.6 h, P<0.05). Oral analgesia with OOXY was approximately GBP 10 less expensive per patient than IVPCA. Oral analgesia with OOXY after THR offers non-inferior analgesia to IVPCA and may offer some logistical and cost advantages.
Comparison of thromboprophylaxis patterns in arthroplasty in public and private hospitals
Cortada, Aline Pinheiro dos Santos; da Silva, Telma Gomes; da Silva, André Campos; Golmia, Ricardo Prado; Guerra, Renata Leborato; Takemoto, Maíra Libertad Soligo; Monteiro, Roberta Dyonisio Canaveira; Scheinberg, Morton Aaron
2015-01-01
Objective To compare therapy for prophylaxis of venous thromboembolism and costs related to hospitalization of patients undergoing total knee and hip replacement within the context of the Brazilian health system. Methods A retrospective study of patients undergoing arthroplasty in 2010 in a public hospital and two private hospitals in the state of São Paulo, conducted by means of medical record review. Costs were estimated based on the use of health care resources during hospitalization. A descriptive analysis was performed using frequency and mean (standard deviation) according to the type of care delivered (by public or private organization). Results A total of 215 patients were evaluated, and 56.3% were submitted to knee surgery and 43.7%, to hip replacement. Approximately 88% and 98% of patients from public and private health services, respectively, received some form of venous thromboembolism prophylaxis, and enoxaparin was the drug most widely used in both systems. The total cost of prophylaxis was R$ 1,873.01 (R$ 26.38 per patient) in the public service and R$ 21,559.73 (R$ 163.33 per patient) in the private service. For the individuals who presented with thromboembolism, the average cost of hospitalization was R$ 6,210.80 and R$ 43,792.59 per patient in public and private health services, respectively. Conclusion Thromboembolism prophylaxis in patients undergoing arthroplasty is most commonly used in the private health services than public organizations, despite its high costs in both services. The cost per patient with thrombosis during hospitalization was higher than the total cost of prophylaxis, suggesting that prevention is associated to better cost-benefit ratio. PMID:26313439
Brock, Timothy M; Sidaginamale, Raghavendra; Rushton, Steven; Nargol, Antoni V F; Bowsher, John G; Savisaar, Christina; Joyce, Tom J; Deehan, David J; Lord, James K; Langton, David J
2015-12-01
Taper wear at the head-neck junction is a possible cause of early failure in large head metal-on-metal (LH-MoM) hip replacements. We hypothesized that: (i) taper wear may be more pronounced in certain product designs; and (ii) an increased abductor moment arm may be protective. The tapers of 104 explanted LH-MoM hip replacements revised for adverse reaction to metal debris (ARMD) from a single manufacturer were analyzed for linear and volumetric wear using a co-ordinate measuring machine. The mated stem was a shorter 12/14, threaded trunnion (n=72) or a longer, smooth 11/13 trunnion (n=32). The abductor moment arm was calculated from pre-revision radiographs. Independent predictors of linear and volumetric wear included taper angle, stem type, and the horizontal moment arm. Tapers mated with the threaded 12/14 trunnion had significantly higher rates of volumetric wear (0.402 mm3/yr vs. 0.123 mm3/yr [t=-2.145, p=0.035]). There was a trend to larger abductor moment arms being protective (p=0.055). Design variation appears to play an important role in taper-trunnion junction failure. We recommend that surgeons bear these findings in mind when considering the use of a short, threaded trunnion with a cobalt-chromium head. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
The influence of resting periods on friction in the artificial hip.
Nassutt, Roman; Wimmer, Markus A; Schneider, Erich; Morlock, Michael M
2003-02-01
Insufficient tribologic performance of total joint components is a major cause of prostheses failure. Wear has been studied intensively using testing machines that apply continuous motions. Human locomotion, however, is not well represented by continuous motions alone. Singular events and resting periods are a substantial part of daily activities. Resting does influence adhesion in the artificial joint with possible effects on friction, wear, and loosening. The current study evaluated the effects of resting on the frictional properties of hip prosthesis components. The activity measurements of 32 patients with artificial hip replacements were analyzed for resting durations of the hip. A pin-on-ball screening device was used to determine friction after characteristic resting periods and during continuous oscillating motion. All common articulation pairings were investigated. Prolonged and frequent resting periods of the hip were found for the patients. Initial friction increased with increasing resting duration for all tested materials (between 41% and 191%). The metal-on-metal articulations showed the highest friction level (0.098 for sliding) and the highest increase (191%) in friction with resting duration (0.285 after resting periods of 60 seconds). A high static frictional moment after resting periods might present a risk for aseptic implant loosening. Therefore, large head diameters of metal-on-metal joints should be used with caution, especially when additional unfavorable risk factors such as obesity, weak bone-implant interface, or high activity level are present.
Rutenberg, Tal Frenkel; Warshevski, Yaniv; Gold, Aviram; Shasha, Nadav; Snir, Nimrod; Chechik, Ofir; Dolkart, Oleg; Eilig, Dynai; Herman, Amir; Rath, Ehud; Kramer, Moti; Drexler, Michael
2018-05-08
The Mayo metaphysical conservative femoral stem (Zimmer, Warsaw, Indiana) is a wedge-shaped implant designed to transfer loads proximally, reduce femoral destruction, and enable the preservation of bone stock in the proximal femur. Thus, it is a potentially preferred prosthesis for active, non-elderly patients who may require additional future surgeries. This retrospective case study analyzed the outcomes of consecutive patients who underwent total hip replacements with this stem between May 2001 and February 2013. All patients underwent clinical assessment, radiological evaluation for the presence and development of radiolucent lines, and functional assessment (numerical analog scale, Harris hip score, and Short Form-12 questionnaire). Ninety-five hips (79 patients) were available for analysis. The patients' mean age was 43 years (range, 18-64 years), and the mean follow-up was 97 months (range, 26.9-166 months). The postoperative clinical assessments and functional assessments revealed significant improvements. Sixteen patients (20.3%) had 18 orthopedic complications, the most common of which were an intraoperative femoral fracture and implant dislocation requiring revision surgeries in 10 hips (10.5%). Radiological analysis revealed evidence of femoral remodeling in 64 (67.4%) implants, spot welds (neocortex) in 35 (36.8%), and osteolysis in 3 (3.2%). These results suggest that the conservative hip femoral implant has an unacceptable complication rate for non-elderly patients. [Orthopedics. 201x; xx(x):xx-xx.]. Copyright 2018, SLACK Incorporated.
Geurts, Jan A P; Janssen, Daniël M C; Kessels, Alfons G H; Walenkamp, Geert H I M
2013-12-01
Deep postoperative and hematogenous prosthesis infections may be treated with retention of the prosthesis, if the prosthesis is stable. How long the infection may be present to preclude a good result is unclear. We retrospectively studied 89 deep-infected stable prostheses from 69 total hip replacements and 20 total knee replacements. There were 83 early or delayed postoperative infections and 6 hematogenous. In the postoperative infections, treatment had started 12 days to 2 years after implantation. In the hematogenous infections, symptoms had been present for 6 to 9 days. The patients had been treated with debridement, prosthesis retention, systemic antibiotics, and local antibiotics: gentamicin-PMMA beads or gentamicin collagen fleeces. The minimum follow-up time was 1.5 years. We investigated how the result of the treatment had been influenced by the length of the period the infection was present, and by other variables such as host characteristics, infection stage, and type of bacteria. In postoperative infections, the risk of failure increased with a longer postoperative interval: from 0.2 (95% CI: 0.1-0.3) if the treatment had started ≥ 4 weeks postoperatively to 0.5 (CI: 0.2-0.8) if it had started at ≥ 8 weeks. The relative risk for success was 0.6 (CI: 0.3-0.95) if the treatment had started ≥ 8 weeks. In the hematogenous group, 5 of 6 infections had been treated successfully. A longer delay before the start of the treatment caused an increased failure rate, but this must be weighed against the advantage of keeping the prosthesis. We consider a failure rate of < 50% to be acceptable, and we therefore advocate keeping the prosthesis for up to 8 weeks postoperatively, and in hematogenous infections with a short duration of symptoms.
Vincent, John; Alshaygy, Ibrahim; Muir, Jeffrey M; Kuzyk, Paul
2018-01-01
While intraoperative navigation systems have been shown to improve outcomes in primary total hip arthroplasty (THA), their use in the context of revision has been largely overlooked. This case report presents the first documented use of an imageless navigation tool in the context of revision THA, and an unexpected benefit to the surgical procedure as a result. An 84-year-old female patient presented following five episodes of dislocation of the left hip and with pain in the left buttock, groin, and posterior aspect of her hip. Relevant surgical history included primary hip arthroplasty in 1999 and the first revision in 2014. Preoperative analysis revealed a constrained liner that had become disengaged and migrated inferiorly, lodging at the distal aspect of the femoral neck. Acetabular protrusion was also noted. The pre-operative plan included the replacement of the fragmented liner and likely of the acetabular cup due to hardware failure. Intraoperative assessment, however, revealed that the cup was in good condition and would be difficult to remove due to substantial bony ingrowth. With the assistance of imageless navigation, the orientation of the acetabular cup was determined and a new constrained liner was cemented into the preexisting acetabular component at an altered orientation, correcting anteversion by 7°. In revision hip arthroplasty cases, image-based navigation is limited by the presence of existing implants and corresponding metal artefact. This case demonstrates the successful use of an imageless navigation tool for revision surgery. Use of navigation led to the unexpected intraoperative discovery that the acetabular cup was in an acceptable state, and allowed the surgical team to correct the position of the cup using a constrained liner, thus preserving the cup. This significantly benefitted patient outcome, due to the risks associated with the removal of a firmly fixated acetabular cup. While more extensive research is required, this case demonstrates that imageless navigation may be an indispensable tool for revision surgery.
Ceretti, M; Fanelli, M; Pappalardo, S
2014-01-01
The acetabular shell mobilization is the main long-term complication in total hip replacement. Metal-back fracture has also to be considered among the possible causes of shell mobilization. A case is presented of bilateral acetabular shell mobilization due to the trabecular covering de-soldering from the metal-back in a 43 year-old patient, 13-14 years after the first surgery. Copyright © 2013 SECOT. Published by Elsevier Espana. All rights reserved.
The association of proximal femoral shape and incident radiographic hip OA in elderly women.
Lynch, J A; Parimi, N; Chaganti, R K; Nevitt, M C; Lane, N E
2009-10-01
Variations in femoral head shape are reported to predict incident hip osteoarthritis (OA). This study evaluated if proximal femur shape at baseline was a risk factor for incident radiographic hip OA (RHOA) after 8.3 years of follow-up in a cohort of elderly Caucasian women. Supine pelvic radiographs were obtained as part of the Study of Osteoporotic Fractures (SOF) at baseline and Visit 5 (8.3 years later), and were scored for RHOA. A nested case-control study was performed: hips were eligible for inclusion if they had no prevalent RHOA in either hip at baseline. Cases of incident RHOA were defined as no RHOA at baseline and RHOA in their right hip present at Visit 5 [or right total hip replacement (THR) for OA between baseline for follow-up] and a random selection of one half of all incident RHOA cases plus right THR cases (n=102) were chosen. A random selection (n=249) of control subjects who had no RHOA in their right hip at both baseline and follow-up visit were included for comparison. The shape of the right proximal femur was outlined on a digitized baseline radiograph and a statistical image analysis technique, Active Shape Modeling (ASM), was used to generate 10 unique and independent "modes" or variations in shape, which explained 95% of the variance in the shape of the proximal femurs studied. Any hip shape was therefore described as the average shape plus a linear combination of these 10 independent modes of variation. The values for each of these 10 modes for each hip analyzed were entered into a logistic regression model as independent predictors of incident RHOA adjusting for covariates. The incident RHOA cases were slightly taller, heavier and had higher total hip bone mineral density (BMD) than control subjects (P<0.05), but were otherwise similar demographically. Results of ASM showed that Modes 1, 2 and 3 together explained 81% of the variance in proximal femur shape among all subjects analyzed. Modes 3, 5, 9 which accounted for 8.9%, 3.3% and 0.8% of the variance respectively, were significant predictors of incident RHOA with adjusted odds-ratios ranging from 1.61 to 1.99 (P<0.001) for every 1 standard deviation (SD) increase in the mode score. These results suggest that variations in the relative sizes of the femoral head and neck at baseline are modest determinants of incident RHOA in elderly Caucasian women.
Inpatient mortality after elective primary total hip and knee joint arthroplasty in Botswana.
Lisenda, Laughter; Mokete, Lipalo; Mkubwa, Joseph; Lukhele, Mkhululi
2016-12-01
Total hip and knee joint arthroplasty (TJA) rank among the most successful orthopaedic operations. Several developing countries in Africa have started to perform these procedures that are routine in developed countries. The aims of this study were to measure the incidence and assess the determinants of in-hospital mortality after elective primary TJA in our unit and compare it with published data. This was a retrospective study of the first consecutive cohort of patients who underwent elective primary TJA in Princess Marina Hospital, Botswana between March 2009 and October 2015 (6.5 years). 346 elective joint replacements were performed comprising 153 total hip arthroplasties (THA) and 193 total knee arthroplasties (TKA); 36 % of the THA were in female patients and 82 % of TKA were in females. The mean age was 64.5 years (range 26-86). Three patients died giving an inpatient mortality rate of 0.86 %. These three mortalities represent 1.55 % (three out of 193) of all the TKA. There were no deaths after THA. The cause of mortality in two patients was an adverse cardiac event while the third mortality was due to pulmonary embolism. The inpatient mortality rate of 0.86 % following TJA is higher than the reported rates in the developed countries but comparable with data from other developing countries. The inpatient mortality rate following TKA was higher than that following THA and cardiovascular events proved to be the main cause of death. We recommend formal cardiology assessment and close peri-operative monitoring of all patients with a history of cardiovascular disease undergoing TJA.
Gill, Stephen D; de Morton, Natalie A; Mc Burney, Helen
2012-10-01
To assess and compare the validity of six physical function measures in people awaiting hip or knee joint replacement. Eighty-two people awaiting hip or knee replacement were assessed using six physical function measures including the WOMAC Function scale, SF-36 Physical Function scale, SF-36 Physical Component Summary scale, Patient Specific Functional Scale, 30-second chair stand test, and 50-foot timed walk. Validity was assessed using a head-to-head comparison design. Convergent validity was demonstrated with significant correlations between most measures (Spearman's rho 0.22 to 0.71). The Patient Specific Functional Scale had the lowest correlations with other measures of physical function. Discriminant validity was demonstrated with low correlations between mental health and physical function scores (Spearman's rho -0.12 to 0.33). Only the WOMAC Function scale, 30-second chair stand test, and 50-foot timed walk demonstrated known groups validity when scores for participants who walked with a gait aid were compared with those who did not. Standardized response means and Guyatt's responsiveness indexes indicated that the SF-36 was the least responsive measure. For those awaiting joint replacement surgery of the hip or knee, the current investigation found that the WOMAC Function scale, 30-second chair stand test, and 50-foot timed walk demonstrated the most evidence of validity. The Patient Specific Functional Scale might complement other measures by capturing a different aspect of physical function.
Geissler, Alexander; Scheller-Kreinsen, David; Quentin, Wilm
2012-08-01
This paper assesses the variations in costs and length of stay for hip replacement cases in Austria, England, Estonia, Finland, France, Germany, Ireland, Poland, Spain and Sweden and examines the ability of national diagnosis-related group (DRG) systems to explain the variation in resource use against a set of patient characteristic and treatment specific variables. In total, 195,810 cases clustered in 712 hospitals were analyzed using OLS fixed effects models for cost data (n=125,698) and negative binominal models for length-of-stay data (n=70,112). The number of DRGs differs widely across the 10 European countries (range: 2-14). Underlying this wide range is a different use of classification variables, especially secondary diagnoses and treatment options are considered to a different extent. In six countries, a standard set of patient characteristics and treatment variables explain the variation in costs or length of stay better than the DRG variables. This raises questions about the adequacy of the countries' DRG system or the lack of specific criteria, which could be used as classification variables. Copyright © 2012 John Wiley & Sons, Ltd.
The economics of using prophylactic antibiotic-loaded bone cement in total knee replacement.
Gutowski, C J; Zmistowski, B M; Clyde, C T; Parvizi, J
2014-01-01
The rate of peri-prosthetic infection following total joint replacement continues to rise, and attempts to curb this trend have included the use of antibiotic-loaded bone cement at the time of primary surgery. We have investigated the clinical- and cost-effectiveness of the use of antibiotic-loaded cement for primary total knee replacement (TKR) by comparing the rate of infection in 3048 TKRs performed without loaded cement over a three-year period versus the incidence of infection after 4830 TKRs performed with tobramycin-loaded cement over a later period of time of a similar duration. In order to adjust for confounding factors, the rate of infection in 3347 and 4702 uncemented total hip replacements (THR) performed during the same time periods, respectively, was also examined. There were no significant differences in the characteristics of the patients in the different cohorts. The absolute rate of infection increased when antibiotic-loaded cement was used in TKR. However, this rate of increase was less than the rate of increase in infection following uncemented THR during the same period. If the rise in the rate of infection observed in THR were extrapolated to the TKR cohort, 18 additional cases of infection would have been expected to occur in the cohort receiving antibiotic-loaded cement, compared with the number observed. Depending on the type of antibiotic-loaded cement that is used, its cost in all primary TKRs ranges between USD $2112.72 and USD $112 606.67 per case of infection that is prevented.
Kosukegawa, Ima; Nagoya, Satoshi; Kaya, Mitsunori; Sasaki, Koichi; Sasaki, Mikito; Yamashita, Toshihiko
2011-09-01
We report a case with hypersensitivity to CoCr in total hip arthroplasty coupled with conventional polyethylene and CoCr femoral head. The patient complained of left hip pain and systemic fever, and computed tomography imaging revealed a periprosthetic cystic lesion, so we performed revision total hip arthroplasty using a titanium stem and ceramic head and highly crosslinked polyethylene. Hip pain and cystic lesion disappeared 3 years after revision surgery. Copyright © 2011 Elsevier Inc. All rights reserved.
Novel chitosan/diclofenac coatings on medical grade stainless steel for hip replacement applications
NASA Astrophysics Data System (ADS)
Finšgar, Matjaž; Uzunalić, Amra Perva; Stergar, Janja; Gradišnik, Lidija; Maver, Uroš
2016-05-01
Corrosion resistance, biocompatibility, improved osteointegration, as well the prevention of inflammation and pain are the most desired characteristics of hip replacement implants. In this study we introduce a novel multi-layered coating on AISI 316LVM stainless steel that shows promise with regard to all mentioned characteristics. The coating is prepared from alternating layers of the biocompatible polysaccharide chitosan and the non-steroid anti-inflammatory drug (NSAID), diclofenac. Electrochemical methods were employed to characterize the corrosion behavior of coated and uncoated samples in physiological solution. It is shown that these coatings improve corrosion resistance. It was also found that these coatings release the incorporated drug in controlled, multi-mechanism manner. Adding additional layers on top of the as-prepared samples, has potential for further tailoring of the release profile and increasing the drug dose. Biocompatibility was proven on human-derived osteoblasts in several experiments. Only viable cells were found on the sample surface after incubation of the samples with the same cell line. This novel coating could prove important for prolongation of the application potential of steel-based hip replacements, which are these days often replaced by more expensive ceramic or other metal alloys.
Novel chitosan/diclofenac coatings on medical grade stainless steel for hip replacement applications
Finšgar, Matjaž; Uzunalić, Amra Perva; Stergar, Janja; Gradišnik, Lidija; Maver, Uroš
2016-01-01
Corrosion resistance, biocompatibility, improved osteointegration, as well the prevention of inflammation and pain are the most desired characteristics of hip replacement implants. In this study we introduce a novel multi-layered coating on AISI 316LVM stainless steel that shows promise with regard to all mentioned characteristics. The coating is prepared from alternating layers of the biocompatible polysaccharide chitosan and the non-steroid anti-inflammatory drug (NSAID), diclofenac. Electrochemical methods were employed to characterize the corrosion behavior of coated and uncoated samples in physiological solution. It is shown that these coatings improve corrosion resistance. It was also found that these coatings release the incorporated drug in controlled, multi-mechanism manner. Adding additional layers on top of the as-prepared samples, has potential for further tailoring of the release profile and increasing the drug dose. Biocompatibility was proven on human-derived osteoblasts in several experiments. Only viable cells were found on the sample surface after incubation of the samples with the same cell line. This novel coating could prove important for prolongation of the application potential of steel-based hip replacements, which are these days often replaced by more expensive ceramic or other metal alloys. PMID:27215333
Physical activity of elderly patients after total hip arthroplasty.
Cukras, Zbigniew; Praczko, Katarzyna; Kostka, Tomasz; Jegier, Anna
2007-01-01
Total hip arthroplasty (THA) is the most common method of treatment of severe hip osteoarthritis. There is little data concerning the physical activity of total hip arthroplasty patients in Poland and investigations to explore this area are useful. The aim of the study was to describe the post-operative physical activity of total hip arthroplasty patients. A total of 146 adult people were examined, among which 28 men and 41 women had undergone total hip arthroplasty due to primary osteoarthritis of the hip, while another 32 men and 41 women matched for age who had not undergone hip surgery for osteoarthritis served as controls. The physical activity of study participants was assessed with the 7-Day Physical Activity Recall Questionnaire. All participants were also asked about the type and amount of physical activity they engaged in to maintain good health. Physical activity measured as the total amount of calories expended through physical activity per week was similar in the post-THA patients compared to the controls. The only differences were a smaller amount of calories expended during low-intensity physical activity by men after total hip arthroplasty compared to men who had not undergone surgery for osteoarthritis and a smaller amount of calories expended through high-intensity physical activity by women after total hip arthroplasty compared to female controls. The kinds of recreational physical activity most commonly practised by patients a mean of two years after total hip arthroplasty were marching, bicycling and general body conditioning exercises (usually the continuation of exercises recommended during post-operative rehabilitation). The percentage of post-THA patients undertaking physical activity for the prevention of non-communicable diseases was low. Physical activity should be more effectively encouraged in patients after total hip arthroplasty.
Kwon, Young-Min; Khormaee, Sariah; Liow, Ming Han Lincoln; Tsai, Tsung-Yuan; Freiberg, Andrew A; Rubash, Harry E
2016-10-19
Modularity in total hip arthroplasty facilitates intraoperative restoration of patient anatomy. Although dual-taper modular total hip arthroplasty offers potential advantages for optimizing the hip center of rotation, it has been associated with modular taper corrosion. This corrosion has led to adverse local tissue reactions (pseudotumors) at the neck-stem junction and elevated metal-ion levels. However, the occurrence of taper-corrosion-related pseudotumors in patients who remain asymptomatic following total hip arthroplasty with a dual-taper modular femoral stem remains largely unknown. The aims of this study were (1) to determine the prevalence of asymptomatic pseudotumors by utilizing metal artifact reduction sequence magnetic resonance imaging (MARS-MRI) and (2) compare serum metal-ion levels between symptomatic and asymptomatic patients with a dual-taper modular stem total hip replacement. We performed a retrospective cross-sectional study of 97 consecutive patients who had been treated with a dual-taper modular femoral stem total hip arthroplasty. Eighty-three patients were stratified into symptomatic and asymptomatic groups and evaluated with MARS-MRI, measurement of serum metal-ion levels, and the University of California at Los Angeles (UCLA) functional hip score. The prevalence of pseudotumors as determined with MARS-MRI was 15% in our asymptomatic patients and 36% in the overall cohort. The median serum cobalt level and cobalt/chromium ratio were significantly higher in patients with a pseudotumor than in those without a pseudotumor (8.0 versus 2.0 μg/L [p = 0.004] and 10.3 versus 2.4 μg/L [p = 0.012], respectively). However, there was no significant difference in the serum cobalt level or cobalt/chromium ratio between symptomatic patients with a pseudotumor and asymptomatic patients with a pseudotumor (7.6 versus 6.2 μg/L [p = 0.37] and 8.3 versus 10.6 μg/L [p = 0.46], respectively). The UCLA scores of asymptomatic patients with a pseudotumor were similar to those of patients without a pseudotumor (6.7 versus 6.6). The prevalence of asymptomatic taper-corrosion-related pseudotumors on MARS-MRI in this study demonstrated that the absence of symptoms does not exclude the presence of adverse local tissue reactions. Elevated cobalt levels and cobalt/chromium ratios were associated with the presence of pseudotumors in asymptomatic and symptomatic patients. Cross-sectional imaging such as MARS-MRI is indicated for patients with elevated metal-ion levels. A longitudinal study is required to determine whether asymptomatic patients with taper-corrosion-related pseudotumors will develop symptoms with time. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.
Mehra, Tarun; Moos, Rudolf M; Seifert, Burkhardt; Bopp, Matthias; Senn, Oliver; Simmen, Hans-Peter; Neuhaus, Valentin; Ciritsis, Bernhard
2017-12-01
The assessment of structural and potentially economic factors determining cost, treatment type, and inpatient mortality of traumatic hip fractures are important health policy issues. We showed that insurance status and treatment in university hospitals were significantly associated with treatment type (i.e., primary hip replacement), cost, and lower inpatient mortality respectively. The purpose of this study was to determine the influence of the structural level of hospital care and patient insurance type on treatment, hospitalization cost, and inpatient mortality in cases with traumatic hip fractures in Switzerland. The Swiss national medical statistic 2011-2012 was screened for adults with hip fracture as primary diagnosis. Gender, age, insurance type, year of discharge, hospital infrastructure level, length-of-stay, case weight, reason for discharge, and all coded diagnoses and procedures were extracted. Descriptive statistics and multivariate logistic regression with treatment by primary hip replacement as well as inpatient mortality as dependent variables were performed. We obtained 24,678 inpatient case records from the medical statistic. Hospitalization costs were calculated from a second dataset, the Swiss national cost statistic (7528 cases with hip fractures, discharged in 2012). Average inpatient costs per case were the highest for discharges from university hospitals (US$21,471, SD US$17,015) and the lowest in basic coverage hospitals (US$18,291, SD US$12,635). Controlling for other variables, higher costs for hip fracture treatment at university hospitals were significant in multivariate regression (p < 0.001). University hospitals had a lower inpatient mortality rate than full and basic care providers (2.8% vs. both 4.0%); results confirmed in our multivariate logistic regression analysis (odds ratio (OR) 1.434, 95% CI 1.127-1.824 and OR 1.459, 95% confidence interval (CI) 1.139-1.870 for full and basic coverage hospitals vs. university hospitals respectively). The proportion of privately insured varied between 16.0% in university hospitals and 38.9% in specialized hospitals. Private insurance had an OR of 1.419 (95% CI 1.306-1.542) in predicting treatment of a hip fracture with primary hip replacement. The seeming importance of insurance type on hip fracture treatment and the large inequity in the distribution of privately insured between provider types would be worth a closer look by the regulatory authorities. Better outcomes, i.e., lower mortality rates for hip fracture treatment in hospitals with a higher structural care level advocate centralization of care.
Evaluation and Referral for Developmental Dysplasia of the Hip in Infants.
Shaw, Brian A; Segal, Lee S
2016-12-01
Developmental dysplasia of the hip (DDH) encompasses a wide spectrum of clinical severity, from mild developmental abnormalities to frank dislocation. Clinical hip instability occurs in 1% to 2% of full-term infants, and up to 15% have hip instability or hip immaturity detectable by imaging studies. Hip dysplasia is the most common cause of hip arthritis in women younger than 40 years and accounts for 5% to 10% of all total hip replacements in the United States. Newborn and periodic screening have been practiced for decades, because DDH is clinically silent during the first year of life, can be treated more effectively if detected early, and can have severe consequences if left untreated. However, screening programs and techniques are not uniform, and there is little evidence-based literature to support current practice, leading to controversy. Recent literature shows that many mild forms of DDH resolve without treatment, and there is a lack of agreement on ultrasonographic diagnostic criteria for DDH as a disease versus developmental variations. The American Academy of Pediatrics has not published any policy statements on DDH since its 2000 clinical practice guideline and accompanying technical report. Developments since then include a controversial US Preventive Services Task Force "inconclusive" determination regarding usefulness of DDH screening, several prospective studies supporting observation over treatment of minor ultrasonographic hip variations, and a recent evidence-based clinical practice guideline from the American Academy of Orthopaedic Surgeons on the detection and management of DDH in infants 0 to 6 months of age. The purpose of this clinical report was to provide literature-based updated direction for the clinician in screening and referral for DDH, with the primary goal of preventing and/or detecting a dislocated hip by 6 to 12 months of age in an otherwise healthy child, understanding that no screening program has eliminated late development or presentation of a dislocated hip and that the diagnosis and treatment of milder forms of hip dysplasia remain controversial. Copyright © 2016 by the American Academy of Pediatrics.
Gagala, J; Tarczynska, M; Gaweda, K; Matuszewski, L
2014-09-01
Osteonecrosis of the femoral head is an entity which occurs mainly in young and active patients aged between 20 and 50. The success of hip joint preserving treatments ranges from 15% to 50% depending on the stage and amount of osteonecrotic lesion. Total hip replacement is indicated in late post-collapse hips but it has unsatisfactory survival because of the wear and osteolysis in young and active patients. Osteochondral allografts have been reported in the treatment of large articular lesions with defects in underlying bone in knee, talus and shoulder. By combining osteoconductive properties of osteochondral allograft with osteogenic abilities of bone marrow-derived mesenchymal cells it has a potential to be an alternative to an autologous graft. The adjunct of hinged joint distraction should minimize stresses in subchondral bone to promote creeping substitution and prevent femoral head collapse. Unlike current treatment modalities, it would provide both structural support and allow bony and articular substitution. Copyright © 2014 Elsevier Ltd. All rights reserved.
Masaracchio, Michael; Hanney, William J.; Liu, Xinliang; Kolber, Morey; Kirker, Kaitlin
2017-01-01
Objective To investigate the role of early initiation of rehabilitation on length of stay (LOS) and cost following total hip arthroplasty, total knee arthroplasty, or unicompartmental knee arthroplasty. Data sources Electronic databases PubMed, CINAHL, Pedro, Embase, AMED, and the Cochrane Library were searched in July 2016. Five additional trials were identified through reference list scanning. Study selection Eligible studies were published in English language peer-reviewed journals; included participants that had undergone total hip arthroplasty, total knee arthroplasty, or unicompartmental knee arthroplasty reported clearly defined timing of rehabilitation onset for at least two groups; and reported at least one measure of LOS or cost. Inclusion criteria were applied by 2 independent authors, with disagreements being determined by a third author. Searching identified 1,029 potential articles, of which 17 studies with 26,614 participants met the inclusion criteria. Data extraction Data was extracted independently by 2 authors, with disagreements being determined by a third author. Methodological quality of each study was evaluated independently by 2 authors using the Downs and Black checklist. Pooled analyses were analyzed using a random-effects model with inverse variance methods to calculate standardized mean differences (SMD) and 95% confidence intervals for LOS. Data synthesis When compared with standard care, early initiation of physical therapy demonstrated a decrease in length of stay for the 4 randomized clinical trials (SMD = -1.90; 95% CI -2.76 to -1.05; I2 = 93%) and for the quasi-experimental and 5 prospective studies (SMD = -1.47; 95% CI -1.85 to -1.10; I2 = 88%). Conclusion Early initiation of rehabilitation following total hip arthroplasty, total knee arthroplasty, or unicompartmental knee arthroplasty is associated with a shorter LOS, a lower overall cost, with no evidence of an increased number of adverse reactions. Additional high quality studies with standardized methodology are needed to further examine the impact of early initiation of physical therapy among patients with joint replacement procedures. PMID:28575058
Jiang, Xin; Sun, Yan-Shan
2017-01-01
The present study estimates the effect of rivaroxaban on preventing deep vein thrombosis (DVT) in aged diabetics with femoral neck fractures after hip replacement. Our study consisted of 236 aged diabetics with femoral neck fractures, which were divided into the rivaroxaban and control groups. Reaction time (R time), clot formation time (K time), α angle (α), maximum amplitude (MA), clot elasticity (G) and coagulation index (CI), prothrombin time (PT) and activated partial thromboplastin time (APTT) were measured. DVT was diagnosed by color duplex Doppler ultrasound (CDDU). The risk factors of DVT were analysed by logistic regression analysis. Compared with the control group, in the rivaroxaban group, R time and K time were extended and α, MA and G decreased 1 day before operation. One day after operation, the rivaroxaban group had less PT and APPT and lower incidence of DVT than the control group. In the two groups, preoperative and postoperative PT and APPT significantly differed. Body mass index (BMI) ≥25, abnormal coagulation indicators, use of cemented femoral hip prosthesis, high haemoglobin content and non-ankle pump exercise after operation were the risk factors for DVT. Rivaroxaban could prevent DVT in aged diabetics with femoral neck fractures after hip replacement. PMID:28442600
Eslam Pour, Aidin; Bradbury, Thomas L; Horst, Patrick K; Harrast, John J; Erens, Greg A; Roberson, James R
2016-07-01
A certified list of all operative cases performed within a 6-month period is a required prerequisite for surgeons taking the American Board of Orthopaedic Surgery Part II oral examination. Using the American Board of Orthopaedic Surgery secure Internet database database containing these cases, this study (1) assessed changing trends for primary and revision total hip arthroplasty (THA) and (2) compared practices and early postoperative complications between 2 groups of examinees, those with and without adult reconstruction fellowship training. Secure Internet database was searched for all 2003-2013 procedures with a Current Procedural Terminology code for THA, hip resurfacing, hemiarthroplasty, revision hip arthroplasty, conversion to THA, or removal of hip implant (Girdlestone, static, or dynamic spacer). Adult reconstruction fellowship-trained surgeons performed 60% of the more than 33,000 surgeries identified (average 28.1) and nonfellowship-trained surgeons performed 40% (average 5.2) (P < .001). Fellowship-trained surgeons performed significantly more revision surgeries for infection (71% vs 29%)(P < .001). High-volume surgeons had significantly fewer complications in both primary (11.1% vs 19.6%) and revision surgeries (29% vs 35.5%) (P < .001). Those who passed the Part II examination reported higher rates of complications (21.5% vs 19.9%). In early practice, primary and revision hip arthroplasties are often performed by surgeons without adult reconstruction fellowship training. Complications are less frequently reported by surgeons with larger volumes of joint replacement surgery who perform either primary or more complex cases. Primary hip arthroplasty is increasingly performed by surgeons early in practice who have completed an adult reconstructive fellowship after residency training. This trend is even more pronounced for more complex cases such as revision or management of infection. Copyright © 2016 Elsevier Inc. All rights reserved.
Fabry, Christian; Kaehler, Michael; Herrmann, Sven; Woernle, Christoph; Bader, Rainer
2014-01-01
Tripolar systems have been implanted to reduce the risk of recurrent dislocation. However, there is little known about the dynamic behavior of tripolar hip endoprostheses under daily life conditions and achieved joint stability. Hence, the objective of this biomechanical study was to examine the in vivo dynamics and dislocation behavior of two types of tripolar systems compared to a standard total hip replacement (THR) with the same outer head diameter. Several load cases of daily life activities were applied to an eccentric and a concentric tripolar system by an industrial robot. During testing, the motion of the intermediate component was measured using a stereo camera system. Additionally, their behavior under different dislocation scenarios was investigated in comparison to a standard THR. For the eccentric tripolar system, the intermediate component demonstrated the shifting into moderate valgus-positions, regardless of the type of movement. This implant showed the highest resisting torque against dislocation in combination with a large range of motion. In contrast, the concentric tripolar system tended to remain in varus-positions and was primarily moved after stem contact. According to the results, eccentric tripolar systems can work well under in vivo conditions and increase hip joint stability in comparison to standard THRs. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.
2012-01-01
Background Aseptic loosening is one of the greatest problems in hip replacement surgery. The rotation center of the hip is believed to influence the longevity of fixation. The aim of this study was to compare the influence of cemented and cementless cup fixation techniques on the position of the center of rotation because cemented cup fixation requires the removal of more bone for solid fixation than the cementless technique. Methods We retrospectively compared pre- and post-operative positions of the hip rotation center in 25 and 68 patients who underwent artificial hip replacements in our department in 2007 using cemented or cementless cup fixation, respectively, with digital radiographic image analysis. Results The mean horizontal and vertical distances between the rotation center and the acetabular teardrop were compared in radiographic images taken pre- and post-operatively. The mean horizontal difference was −2.63 mm (range: -11.00 mm to 10.46 mm, standard deviation 4.23 mm) for patients who underwent cementless fixation, and −2.84 mm (range: -10.87 to 5.30 mm, standard deviation 4.59 mm) for patients who underwent cemented fixation. The mean vertical difference was 0.60 mm (range: -20.15 mm to 10.00 mm, standard deviation 3.93 mm) and 0.41 mm (range: -9.26 mm to 6.54 mm, standard deviation 3.58 mm) for the cementless and cemented fixation groups, respectively. The two fixation techniques had no significant difference on the position of the hip rotation center in the 93 patients in this study. Conclusions The hip rotation center was similarly restored using either the cemented or cementless fixation techniques in this patient cohort, indicating that the fixation technique itself does not interfere with the position of the center of rotation. To completely answer this question further studies with more patients are needed. PMID:22686355
Sabeh, Karim G; Rosas, Samuel; Buller, Leonard T; Roche, Martin W; Hernandez, Victor H
2017-10-01
Total joint arthroplasty (TJA) accounts for more Medicare expenditure than any other inpatient procedure. The Comprehensive Care for Joint Replacement model was introduced to decrease cost and improve quality in TJA. The largest portion of episode-of-care costs occurs after discharge. This study sought to quantify the cost variation of primary total hip arthroplasty (THA) according to discharge disposition. The Medicare and Humana claims databases were used to extract charges and reimbursements to compare day-of-surgery and 91-day postoperative costs simulating episode-of-care reimbursements. Of the patients who underwent primary THA, 257,120 were identified (204,912 from Medicare and 52,208 from Humana). Patients were stratified by discharge disposition: home with home health, skilled nursing facility, or inpatient rehabilitation facility. There is a significant difference in the episode-of-care costs according to discharge disposition, with discharge to an inpatient rehabilitation facility the most costly and discharge to home the least costly. Postdischarge costs represent a sizeable portion of the overall expense in THA, and optimizing patients to allow safe discharge to home may help reduce the cost of THA. Copyright © 2017 Elsevier Inc. All rights reserved.
Johnsen, Marianne Bakke; Hellevik, Alf Inge; Baste, Valborg; Furnes, Ove; Langhammer, Arnulf; Flugsrud, Gunnar; Nordsletten, Lars; Zwart, John Anker; Storheim, Kjersti
2016-02-16
The relationship between leisure time physical activity (LPA) and hip and knee OA and subsequent joint replacement has not yet been clearly defined. Some studies have found the risk of knee replacement (TKR) to increase with high levels of LPA, while others have found no overall relationship to either TKR or hip replacement (THR). The aim was to investigate the association between LPA and the risk of severe end-stage OA, defined as THR or TKR due to primary OA, in a large population-based cohort. Participants in the Nord-Trøndelag Health Study (HUNT) were followed prospectively to identify THR and TKR using the Norwegian Arthroplasty Register. Self-reported LPA was classified as inactive, low, moderate or high. The Cox proportional hazards model was used to calculate hazard ratios (HRs) according to levels of LPA with adjustments for confounding variables. Analyses were performed by age (<45, 45-59 and ≥60 years) and sex. A total of 66 964 participants (mean age 46.8 years (SD 16.3) were included in the analyses. We identified 1636 THRs and 1016 TKRs due to primary OA during 17.0 years (median) of follow-up. High LPA was significantly associated with THR for women <45 years (HR 1.78, 95 % CI 1.08-2.94) and men between 45-59 years (HR 1.53, 95 % CI 1.10-2.13) at baseline. A significant trend was found only among women < 45 years at baseline (p = 0.02). We found that LPA was significantly associated with TKR for women only (HR 1.45, 95 % CI 1.03-2.04). No measures of LPA were associated with TKR for men. In this population-based study, high level of LPA was associated with increased risk of THR where a significant trend of LPA was seen among women <45 years at baseline. For TKR, high LPA was associated with increased risk only in women. In contrast to previous studies, this study shows a possible association between high LPA and the risk of THR.
[Incidence of hip and knee prosthetic infections in a specialized center of Mexico City].
Franco-Cendejas, Rafael; Contreras-Córdova, Erika Lizbeth; Mondragón-Eguiluz, Jaime Arturo; Vanegas-Rodríguez, Edgar Samuel; Ilizaliturri-Sánchez, Víctor Manuel; Galindo-Fraga, Arturo
Hip and knee prosthetic replacements have proven to be the most appropriate treatment in the joints that do not benefit from medical or arthroscopic interventions; however, infections are the most feared complication. It is recommended that the incidence of infection should not exceed 2%. This was an observational, prospective, longitudinal and observational study conducted in patients fitted with a prosthetic joint from August 2011 to July 2012. Patients were followed up pre and post-surgery for one year to identify a prosthetic infection, diagnosed using international parameters. We calculated the incidence of prosthetic infection, as well as the incidence density. A total of 339 patients (179 hip and 160 knee) were included. Variations in the time of pre-operative antibiotics' administration were observed. Six prosthetic infections were identified with an incidence rate of 1.79/339 arthroplasties, 2.2/179 hip procedures, and 1.25/160 knee arthroplasties. An incidence density of 0.02/year for hip arthroplasties and 0.11/year for knee procedures was identified. There were 4 infections of hip and 2 of knee. Five infections were acute and one chronic. The isolated microorganisms were E. faecalis, S. epidermidis (2), S. mitis, S. aureus and P. stomatis. The incidence of prosthetic joint infection in the first year of follow-up at our centre is within the recommended parameters. Surgical techniques and organizational practices influence the results. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.
Design of Composite Hip Prostheses Considering the Long-Term Behavior of the Femur
NASA Astrophysics Data System (ADS)
Lim, Jong Wan; Jeong, Jae Youn; Ha, Sung Kyu
A design method for the hip prosthesis is proposed which can alleviate problems associated with stress shielding, proximal loosening and the high stress of bone-implant interfaces after total hip replacement. The stress shielding which may lead to bone resorption, can cause a loosening of the stem and a fracture of femoral bone. Generally the composites were more suitable for hip prosthesis material in the long-term stability than metallic alloy because design cases of composite materials produced less stress shielding than titanium alloy. A bone remodeling algorithm was implemented in a nonlinear finite element program to predict the long-term performance of the hip prosthesis. The three neck shapes and three cross sections of composite hip were examined. It was found that the stress concentration in the distal region of the titanium stem which may cause the patient's thigh pains was reduced using composite material. The head neck shape was closely related with the cortical bone resorption and the cancellous bone apposition at proximal region whereas the cross-section was closely related with the relative micromotion between interfaces. The convex head neck type with the quadrangle cross-section produced less subsidence at proximal region on the medial side than the others. For all composite material cases, the cancellous bone apposition occurred at partial interfaces, which may result in a stable bio-fixation. The design performances of the convex neck head type with the hexagonal cross-section designed to insure the long-term stability were found to be more suitable than the others.
Pazzaglia, U E; Apostoli, P; Congiu, T; Catalani, S; Marchese, M; Zarattini, G
2011-09-01
A patient with a total hip replacement developed optic, acoustic and peripheral neuropathy from metal ions intoxication, due to the wear products released from the prosthesis. Subsequently the kinetics of the metal ions was studied. Massive wear and acute intoxication allowed a study of the metal ions kinetics and of EDTA treatment. Plasma and other organic fluids were saturated by each of the metal ions released from the exposed surface according to the solubility of each ion; a larger fraction of Co ions was bound within red cells, while the plasmatic fraction appeared more movable. In a patient with a prosthesis subjected to wear, the ions released are from the prosthetic and from the debris surface (spread in the body). The latter is a function of the number and size of particles. Revision of the prosthesis from the point of view of the metal ions kinetics corresponded to a reduction of the releasing surface because of debris washed out by irrigation and tissue excision; however, the metal particles spread by lymphatic circulation continued to release ions even though the source of wear had been removed. Early diagnosis of high metal wear can be ascertained with mass spectrometry and after revision high levels of metal ions can only be reduced with repeated chelating treatment. It is preferable not to revise fractured ceramic components with a polyethylene-metal articulation.
Guillin, Raphaël; Bertaud, Valérie; Garetier, Marc; Fantino, Olivier; Polard, Jean-Louis; Lambotte, Jean-Christophe
2018-06-01
To assess visibility of the acetabular cup in total hip replacement and to determine the value of direct and indirect signs of iliopsoas impingement syndrome with ultrasound. Ultrasound examinations were performed by a single operator in 17 patients with iliopsoas impingement syndrome and 48 control patients. Cup visibility, contact between the cup and psoas tendon, and the presence of indirect signs of iliopsoas impingement syndrome were investigated in all patients. When the acetabular cup was visible, its size and position in relation to the psoas tendon were recorded. Anterior cup visibility (P = .03), contact with the psoas tendon (P < .001), psoas tendinopathy (P = .02), and iliopsoas bursitis (P < .001) were significantly associated with iliopsoas impingement syndrome, the latter reported with specificity of 100%. In the sagittal plane at the level of the psoas tendon, a maximum sagittal length of greater than 5 mm and a posteroanterior cup shift of 3 mm or greater yielded respective sensitivities of 82% and 59% and specificities of 81% and 100%. When iliopsoas impingement syndrome is clinically suspected, the presence of iliopsoas bursitis or a posteroanterior cup shift of greater than 3 mm under the psoas tendon serve to confirm the diagnosis. In the absence of these conditions, a therapeutic test may be necessary because of the incomplete, albeit high, specificity of other signs. © 2017 by the American Institute of Ultrasound in Medicine.
Total hip arthroplasty of dysplastic hip after previous Chiari pelvic osteotomy.
Minoda, Yukihide; Kadowaki, Toru; Kim, Mitsunari
2006-08-01
Many reports have suggested that Chiari pelvic osteotomy would improve the results of acetabular component placement and fixation in subsequent total hip arthroplasty. However, little is known concerning the biomechanical, radiological, and clinical effects of Chiari pelvic osteotomy on subsequent total hip arthroplasty. Ten total hip arthroplasties for developmental dysplasia of the hip after previous Chiari pelvic osteotomy (Chiari group) were compared with 20 total hip arthroplasties for developmental dysplasia of the hip without previous surgery (control group). Preoperative patient demographic data and operative technique were well matched between the groups. The mean duration of follow-up was 3.0 years. Biomechanical, radiological, and clinical evaluations were performed. No acetabular or femoral components exhibited loosening. All patients had good or excellent clinical score according to the Merle d'Aubigne-Postel rating system at the most recent follow-up. Abductor force and joint force were smaller in the Chiari group, although long operative time, more blood loss, and verticalization of joint force were noted in this group. This limited study suggested that Chiari pelvic osteotomy changed the biomechanical features of the hip joint, and that this alteration might have compromised subsequent total hip arthroplasty.
Nemes, Szilard; Rolfson, Ola; Garellick, Göran
2018-02-01
Clinicians considering improvements in health-related quality of life (HRQoL) after total hip replacement (THR) must account for multiple pieces of information. Evidence-based decisions are important to best assess the effect of THR on HRQoL. This work aims at constructing a shared decision-making tool that helps clinicians assessing the future benefits of THR by offering predictions of 1-year postoperative HRQoL of THR patients. We used data from the Swedish Hip Arthroplasty Register. Data from 2008 were used as training set and data from 2009 to 2012 as validation set. We adopted two approaches. First, we assumed a continuous distribution for the EQ-5D index and modelled the postoperative EQ-5D index with regression models. Second, we modelled the five dimensions of the EQ-5D and weighted together the predictions using the UK Time Trade-Off value set. As predictors, we used preoperative EQ-5D dimensions and the EQ-5D index, EQ visual analogue scale, visual analogue scale pain, Charnley classification, age, gender, body mass index, American Society of Anesthesiologists, surgical approach and prosthesis type. Additionally, the tested algorithms were combined in a single predictive tool by stacking. Best predictive power was obtained by the multivariate adaptive regression splines (R 2 = 0.158). However, this was not significantly better than the predictive power of linear regressions (R 2 = 0.157). The stacked model had a predictive power of 17%. Successful implementation of a shared decision-making tool that can aid clinicians and patients in understanding expected improvement in HRQoL following THR would require higher predictive power than we achieved. For a shared decision-making tool to succeed, further variables, such as socioeconomics, need to be considered. © 2016 John Wiley & Sons, Ltd.
A computational parametric study on edge loading in ceramic-on-ceramic total hip joint replacements.
Liu, Feng; Feng, Li; Wang, Junyuan
2018-07-01
Edge loading in ceramic-on-ceramic total hip joint replacement is an adverse condition that occurs as the result of a direct contact between the head and the cup rim. It has been associated with translational mismatch in the centres of rotation of the cup and head, and found to cause severe wear and early failure of the implants. Edge loading has been considered in particular in relation to dynamic separation of the cup and head centres during a gait cycle. Research has been carried out both experimentally and computationally to understand the mechanism including the influence of bearing component positioning on the occurrence and severity of edge loading. However, it is experimentally difficult to measure both the load magnitude and duration of edge loading as it occurs as a short impact within the tight space of hip joints. Computationally, a dynamic contact model, for example, developed using the MSC ADAMS software for a multi-body dynamics simulation can be particularly useful for calculating the loads and characterising the edge loading. The aim of the present study was to further develop the computational model, and improve the predictions of contact force and the understanding of mechanism in order to provide guidance on design and surgical factors to avoid or to reduce edge loading and wear. The results have shown that edge loading can be avoided for a low range of translational mismatch in the centres of rotation of the cup and head during gait at the level of approximately 1.0 mm for a cup at 45° inclination, keeping a correct cup inclination at 45° is important to reduce the edge loading severity, and edge loading can be avoided for a certain range of translational mismatch of the cup and head centres with an increased swing phase load. Copyright © 2018 Elsevier Ltd. All rights reserved.
Muscle strength and areal bone mineral density at the hip in women: a cross-sectional study.
Pasco, Julie A; Holloway, Kara L; Brennan-Olsen, Sharon L; Moloney, David J; Kotowicz, Mark A
2015-05-24
Muscle strengthening exercises are promoted for building and maintaining a healthy skeleton. We aimed to investigate the relationship between muscle strength and areal bone mineral density (BMD) at the hip in women aged 26-97 years. This cross-sectional study utilises data from 863 women assessed for the Geelong Osteoporosis Study. Measures of hip flexor and abductor strength were made using a hand-held dynamometer (Nicholas Manual Muscle Tester). The maximal measure from three trials on each leg was used for analyses. BMD was measured at the hip using dual energy x-ray absorptiometry (DXA; Lunar DPX-L). Total lean mass, body fat mass and appendicular lean mass were determined from whole body DXA scans. Linear regression techniques were used with muscle strength as the independent variable and BMD as the dependent variable. Models were adjusted for age and indices of body composition. Measures of age-adjusted hip flexor strength and hip abductor strength were positively associated with total hip BMD. For each standard deviation (SD) increase in hip flexor strength, the increase in mean total hip BMD (SD) was 10.4 % (p = 0.009). A similar pattern was observed for hip abductor strength, with an increase in mean total hip BMD of 22.8 % (p = 0.025). All associations between hip muscle strength and total hip BMD were independent of height, but were nullified after adjusting for appendicular lean mass or total lean mass. There was a positive association observed between muscle strength and BMD at the hip. However, this association was explained by measures of lean mass.
Figueiredo-Pina, C G; Yan, Y; Neville, A; Fisher, J
2008-04-01
Hip simulator studies have been carried out extensively to understand and test artificial hip implants in vitro as an efficient alternative to obtaining long-term results in vivo. Recent studies have shown that a ceramic-on-metal material combination lowers the wear by up to 100 times in comparison with a typical metal-on-metal design. The reason for this reduction remains unclear and for this reason this study has undertaken simple tribometer tests to understand the fundamental material loss mechanisms in two material combinations: metal-on-metal and ceramic-on-ceramic. A simple-configuration reciprocating pin-on-plate wear study was performed under open-circuit potential (OCP) and with applied cathodic protection (CP) in a serum solution using two tribological couples: firstly, cobalt-chromium (Co-Cr) pins against Co-Cr plates; secondly, Co-Cr pins against alumina (Al2O3) plates. The pin and plate surfaces prior to and after testing were examined by profilometry and scanning electron microscopy. The results showed a marked reduction in wear when CP was applied, indicating that total material degradation under the OCP condition was attributed to corrosion processes. The substitution of the Co-Cr pin with an Al2O3 plate also resulted in a dramatic reduction in wear, probably due to the reduction in the corrosion-wear interactions between the tribological pair.
Cement-in-cement acetabular revision with a constrained tripolar component.
Leonidou, Andreas; Pagkalos, Joseph; Luscombe, Jonathan
2012-02-17
Dislocation of a total hip replacement (THR) is common following total hip arthroplasty (THA). When nonoperative management fails to maintain reduction, revision surgery is considered. The use of constrained acetabular liners has been extensively described. Complete removal of the old cement mantle during revision THA can be challenging and is associated with significant complications. Cement-in-cement revision is an established technique. However, the available clinical and experimental studies focus on femoral stem revision. The purpose of this study was to present a case of cement-in-cement acetabular revision with a constrained component for recurrent dislocations and to investigate the current best evidence for this technique. This article describes the case of a 74-year-old woman who underwent revision of a Charnley THR for recurrent low-energy dislocations. A tripolar constrained acetabular component was cemented over the primary cement mantle following removal of the original liner by reaming, roughening the surface, and thoroughly irrigating and drying the primary cement. Clinical and radiological results were good, with the Oxford Hip Score improving from 11 preoperatively to 24 at 6 months postoperatively. The good short-term results of this case and the current clinical and biomechanical data encourage the use of the cement-in-cement technique for acetabular revision. Careful irrigation, drying, and roughening of the primary surface are necessary. Copyright 2012, SLACK Incorporated.
Lawsuits After Primary and Revision Total Hip Arthroplasties: A Malpractice Claims Analysis.
Patterson, Diana C; Grelsamer, Ronald P; Bronson, Michael J; Moucha, Calin S
2017-10-01
As the prevalence of total hip arthroplasty (THA) expands, so too will complications and patient dissatisfaction. The goal of this study was to identify the common etiologies of malpractice suits and costs of claims after primary and revision THAs. Analysis of 115 malpractice claims filed for alleged neglectful primary and revision THA surgeries by orthopedic surgeons insured by a large New York state malpractice carrier between 1983 and 2011. The incidence of malpractice claims filed for negligent THA procedures is only 0.15% per year in our population. In primary cases, nerve injury ("foot drop") was the most frequent allegation with 27 claims. Negligent surgery causing dislocation was alleged in 18 and leg length discrepancy in 14. Medical complications were also reported, including 3 thromboembolic events and 6 deaths. In revision cases, dislocation and infection were the most common source of suits. The average indemnity payment was $386,153 and the largest single settlement was $4.1 million for an arterial injury resulting in amputation after a primary hip replacement. The average litigation cost to the insurer was $61,833. Nerve injury, dislocation, and leg length discrepancy are the most common reason for malpractice after primary THA. Orthopedic surgeons should continue to focus on minimizing the occurrence of these complications while adequately incorporating details about the risks and limitations of surgery into their preoperative education. Copyright © 2017 Elsevier Inc. All rights reserved.
Grosse, Susann; Haugland, Hans Kristian; Lilleng, Peer; Ellison, Peter; Hallan, Geir; Høl, Paul Johan
2015-01-01
Wear debris-induced inflammation is considered to be the main cause for periprosthetic osteolysis in total hip replacements (THR). The objective of this retrieval study was to examine the tissue reactions and exposure to metal ions and wear particles in periprosthetic tissues and blood samples from patients with titanium (Ti)-based hip prostheses that were revised due to wear, osteolysis, and/or aseptic loosening. Semiquantitative, histological tissue evaluations in 30 THR-patients revealed numerous wear debris-loaded macrophages, inflammatory cells, and necrosis in both groups. Particle load was highest in tissues adjacent to loosened cemented Ti stems that contained mainly submicron zirconium (Zr) dioxide particles. Particles containing pure Ti and Ti alloy elements were most abundant in tissues near retrieved uncemented cups. Polyethylene particles were also detected, but accounted only for a small portion of the total particle number. The blood concentrations of Ti and Zr were highly elevated in cases with high abrasive wear and osteolysis. Our findings indicate that wear particles of different chemical composition induced similar inflammatory responses, which suggests that particle size and load might be more important than the wear particle composition in periprosthetic inflammation and osteolysis. © 2014 The Authors. Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 103B:709–717, 2015. PMID:25051953
Outcomes of Inpatients With and Without Sickle Cell Disease After High-Volume Surgical Procedures
Dinan, Michaela A.; Chou, Chia-Hung; Hammill, Bradley G.; Graham, Felicia L.; Schulman, Kevin A.; Telen, Marilyn J.; Reed, Shelby D.
2009-01-01
In this study, we examined differences in inpatient costs, length of stay, and in-hospital mortality between hospitalizations for patients with and without sickle cell disease (SCD) undergoing high-volume surgical procedures. We used Clinical Classification Software (CCS) codes to identify discharges in the 2002–2005 Nationwide Inpatient Sample of the Healthcare Cost and Utilization Project for patients who had undergone either cholecystectomy or hip replacement. We limited the non-SCD cohort to hospitals where patients with SCD had undergone the same procedure. We compared inpatient outcomes using summary statistics and generalized linear regression analysis to adjust for patient, hospital, and procedural characteristics. Overall, the median age of surgical patients with SCD was more than 3 decades less than the median age of patients without SCD undergoing the same procedure. In recognition of the age disparity, we limited the analyses to patients aged 18 to 64 years. Nonetheless, patients with SCD undergoing cholecystectomy or hip replacement were 12.1 and 14.4 years younger, had inpatient stays that were 73% and 82% longer, and incurred costs that were 46% and 40% higher per discharge than patients without SCD, respectively. Inpatient mortality for these procedures was low, approximately 0.6% for cholecystectomy and 0.2% for hip replacement, and did not differ significantly between patients with and without SCD. Multivariable regression analyses revealed that higher inpatient costs among patients with SCD were primarily attributable to longer hospital stays. Patients with SCD who underwent cholecystectomy or hip replacement required more health care resources than patients without SCD. PMID:19787790
Brewster, Mark; McArthur, John; Mauffrey, Cyril; Lewis, Andrew Charles; Hull, Peter; Ramos, James
2010-01-01
We report the functional results of a case series of Moje first metatarsophalangeal total joint replacements carried out between February 2001 and November 2006. All patients who underwent Moje arthroplasty under the care of a single surgeon were included; outcome scores and complications were recorded annually. A total of 32 joints in 29 consecutive patients were followed for a mean duration of 34 (range 6 to 74) months, and the mean patient age at the time of operation was 56 (range 38 to 79) years. Hallux rigidus was the primary diagnosis in 28 (87.5%) of the cases. The mean American Orthopaedic Foot & Ankle Society Hallux-Metatarsophalangeal-Interphalangeal score at final follow-up was 74/100 (range 9 to 100), with 13 (40.63%) joints rated good to excellent. Two (6.25%) joints were revised to arthrodesis at a mean of 52 (range 41 to 63) months following the arthroplasty procedure, and the overall prevalence of postoperative complications was 6 (18.75%). Based on these results, we concluded that first MTPJ total joint replacement with the Moje device remains promising, but still has room for improvement before the results match those obtained with larger joint (knee, hip) arthroplasty. Copyright 2010 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Measurement of pelvic osteolytic lesions in follow-up studies after total hip arthroplasty
NASA Astrophysics Data System (ADS)
Castaneda, Benjamin; Tamez-Pena, Jose G.; Totterman, Saara; O'Keefe, Regis; Looney, R. John
2006-03-01
Previous studies have demonstrated the plausibility of using volumetric computerized tomography to provide an accurate representation and measurement of volume for pelvic osteolytic lesions following total hip joint replacement. These studies have been performed manually (or computed-assisted) by expert radiologists with the disadvantage of poor reproducibility of the experiment. The purpose of this work is to minimize the effect of user interaction in these experiments by introducing Laplacian level set methods in the volume segmentation process and using temporal articulated registration in order to follow the evolution of a lesion over time. Laplacian level set methods reduce the inter and intra-observer variability by attaching the segmented contour to edges defined in the image while keeping smoothness. The registration process allows the information of the lesion from the first visit to be used in the segmentation process of the current visit. This work compares the automated results on 7 volunteers versus the volume measured manually. Results have shown that the proposed technique is able to track osteolytic lesions and detect changes in volume over time. Intra-reader and inter-observer variabilities were reduced.
Tendon Disorders After Total Hip Arthroplasty: Evaluation and Management.
Capogna, Brian M; Shenoy, Kartik; Youm, Thomas; Stuchin, Steven A
2017-10-01
Most patients who undergo total hip arthroplasty are very satisfied with their outcomes. However, there is a small subset of patients who have persistent pain after surgery. The etiology of pain after total hip arthroplasty varies widely; however, tendon disorders are a major cause of debilitating pain that often go unrecognized. We performed a literature review to identify the most common tendon pathologies after total hip arthroplasty which include iliopsoas tendinitis, greater trochanteric pain syndrome, snapping hip syndrome, and abductor tendinopathy. We present a simplified approach highlighting the presentation and management of patients with suspected tendinopathies after total hip arthroplasty. These tendinopathies are treatable, and management begins with nonoperative modalities; however, in cases not responsive to conservative management, operative intervention may be necessary. Tendinopathies after total hip arthroplasty sometimes go unrecognized but when treated can result in higher surgeon and patient satisfaction. Copyright © 2017 Elsevier Inc. All rights reserved.
Soo, M; Sneddon, N W; Lopez-Villalobos, N; Worth, A J
2015-03-01
To use estimated breeding value (EBV) analysis to investigate the genetic trend of the total hip score (to assess canine hip dysplasia) in four populous breeds of dogs using the records from the New Zealand Veterinary Association (NZVA) Canine Hip Dysplasia Scheme database (1991 to 2011). Estimates of heritability and EBV for the NZVA total hip score of individual dogs from the German Shepherd, Labrador Retriever, Golden Retriever and Rottweiler breeds were obtained using restricted maximum likelihood procedures with a within-breed linear animal model. The model included the fixed effects of gender, birth year, birth season, age at scoring and the random effect of animal. The pedigree file included animals recorded between 1990 and 2011. A total of 2,983 NZVA hip score records, from a pedigree of 3,172 animals, were available for genetic evaluation. Genetic trends of the NZVA total hip score were calculated as the regression coefficient of the EBV (weighted by reliabilities) on year of birth. The estimates of heritability for hip score were 0.32 (SE 0.08) in German Shepherd, 0.37 (SE 0.08) in Labrador Retriever, 0.29 (SE 0.08) in Golden Retriever and 0.52 (SE 0.18) in Rottweiler breeds. Genetic trend analysis revealed that only the German Shepherd breed exhibited a genetic trend towards better hip conformation over time, with a decline of 0.13 (SE 0.04) NZVA total hip score units per year (p<0.001). The genetic trends of total hip score for the remaining three breeds were not significantly different from zero (p>0.1). Despite moderate heritability of the NZVA total hip score, there has not been substantial improvement of this trait for the four breeds analysed in the study period. Greater improvement in reducing the prevalence of canine hip dysplasia may be possible if screening were to be compulsory as a requirement for registration of pedigree breeding stock, greater selection pressure were to be applied and selection of breeding stock made on the basis on an individual's EBV rather than the NZVA total hip score alone.
Schwabe, P; Märdian, S; Perka, C; Schaser, K-D
2016-04-01
Reconstruction/stable fixation of the acetabular columns to create an adequate periacetabular requirement for the implantation of a revision cup. Displaced/nondisplaced fractures with involvement of the posterior column. Resulting instability of the cup in an adequate bone stock situation. Periprosthetic acetabulum fractures with inadequate bone stock. Extended periacetabular defects with loss of anchorage options. Isolated periprosthetic fractures of the anterior column. Septic loosening. Dorsal approach. Dislocation of hip. Mechanical testing of inlaying acetabular cup. With unstable cup situation explantation of the cup, fracture fixation of acetabulum with dorsal double plate osteosynthesis along the posterior column. Cup revision. Hip joint reposition. Early mobilization; partial weight bearing for 12 weeks. Thrombosis prophylaxis. Clinical and radiological follow-ups. Periprosthetic acetabular fracture in 17 patients with 9 fractures after primary total hip replacement (THR), 8 after revision THR. Fractures: 12 due to trauma, 5 spontaneously; 7 anterior column fractures, 5 transverse fractures, 4 posterior column fractures, 1 two column fracture after hemiendoprosthesis. 5 type 1 fractures and 12 type 2 fractures. Operatively treated cases (10/17) received 3 reinforcement ring, 2 pedestal cup, 1 standard revision cup, cup-1 cage construct, 1 ventral plate osteosynthesis, 1 dorsal plate osteosynthesis, and 1 dorsal plate osteosynthesis plus cup revision (10-month Harris Hip Score 78 points). Radiological follow-up for 10 patients: consolidation of fractures without dislocation and a fixed acetabular cup. No revision surgeries during follow-up; 2 hip dislocations, 1 transient sciatic nerve palsy.
Oral nutrition or water loading before hip replacement surgery; a randomized clinical trial.
Ljunggren, Stefan; Hahn, Robert G
2012-07-02
Surgery induces insulin resistance that might be alleviated by a nutritional drink given preoperatively. The authors hypothesized that some of the beneficial effects of the drink could be attributed to the volume component (approximately 1 L) rather than to the nutrients. Sixty patients scheduled for elective total hip replacement under spinal anesthesia were recruited to a clinical trial, and randomly allocated to preoperative fasting, to oral ingestion of tap water, or to oral ingestion of a carbohydrate drink. An intravenous glucose tolerance test calculated glucose clearance and insulin sensitivity on the day before surgery, in the postoperative ward, and on the day after surgery. Other parameters were stress (cortisol in plasma and urine), muscle catabolism (urinary 3-methylhistidine), and wellbeing. Fifty-seven patients completed the study. In the postoperative ward, the glucose clearance and the insulin response had decreased from the previous day by 23% and 36%, respectively. Insulin sensitivity did not decrease until the next morning (-48%) and was due to an increased insulin response (+51%). Cortisol excretion was highest on the day of surgery, while 3-methylhistidine increased 1 day later. Follow-up on the third postoperative day showed an average of 1.5 complications per patient. Wellbeing was better 2 weeks after than before the surgery. None of the measured parameters differed significantly between the study groups. Preoperative ingestion of tap water or a nutritional drink had no statistically significant effect on glucose clearance, insulin sensitivity, postoperative complications, or wellbeing in patients undergoing elective hip surgery.
Rezaei, Farshid; Hassani, Kamran; Solhjoei, Nosratollah; Karimi, Alireza
2015-12-01
Total hip replacement (THR) has been ranked within the most typical surgical processes in the world. The durability of the prosthesis and loosening of prosthesis are the main concerns that mostly reported after THR surgeries. In THR, the femoral prosthesis can be fixed by either cement or cementless methods in the patient's bones. In both procedures, the stability of the prosthesis in the hosted bone has a key asset in its long-term durability and performance. This study aimed to execute a comparative finite element simulation to assess the load transfer between the prosthesis, which is made of carbon/PEEK composite and stainless steel/titanium, and the femur bone. The mechanical behavior of the cortical bone was assumed as a linear transverse isotropic while the spongy bone was modeled like a linear isotropic material. The implants were made of stainless steel (316L) and titanium alloy as they are common materials for implants. The results showed that the carbon/PEEK composites provide a flatter load transfer from the upper body to the leg compared to the stainless steel/titanium prosthesis. Furthermore, the results showed that the von Mises stress, principal stress, and the strain in the carbon/PEEK composites prosthesis were significantly lower than that made of the stainless steel/titanium. The results also imply that the carbon/PEEK composites can be applied to introduce a new optimum design for femoral prosthesis with adjustable stiffness, which can decrease the stress shielding and interface stress. These findings will help clinicians and biomedical experts to increase their knowledge about the hip replacement.
Zanon, David C; Gralher, Dieter; Müller-Staub, Maria
2017-01-01
Background: Pain affects patients' rehabilitation after hip replacement surgery. Aim: The study aim was to compare patients' responses, on their received pain relieving nursing interventions after hip replacement surgery, with the documented interventions in their nursing records. Method: A mixed methods design was applied. In order to evaluate quantitative data the instrument „Quality of Diagnoses, Interventions and Outcomes“ (Q-DIO) was further developed to measure pain interventions in nursing records (Q-DIO-Pain). Patients (n = 37) answered a survey on the third postoperative day. The patients' survey findings were then compared with the Q-DIO-Pain results and cross-validated by qualitative interviews. Results: The most reported pain level was „no pain“ (NRS 0 – 10 Points). However, 17 – 50 % of patients reported pain levels of three or higher and 11 – 22 % of five or higher in situations of motion / ambulation. A significant match between patients' findings and Q-DIO-Pain results was found for the intervention „helping to adapt medications“ (n = 32, ICC = 0.111, p = 0.042, CI 95 % 2-sided). Otherwise no significant matches were found. Interviews with patients and nurses confirmed that far more pain-relieving interventions affecting „Acute Pain“ were carried out, than were documented. Conclusions: Based on the results, pain assessments and effective pain-relieving interventions, especially before or after motion / ambulation should be improved and documented. It is recommended to implement a nursing standard for pain control.
Punt, Ilona M.; Austen, Shennah; Cleutjens, Jack P.M.; Kurtz, Steven M.; ten Broeke, René H.M.; van Rhijn, Lodewijk W.; Willems, Paul C.; van Ooij, André
2011-01-01
Study design Comparative study. Objective To compare periprosthetic tissue reactions observed after total disc replacement (TDR), total hip arthroplasty (THA) and total knee arthroplasty (TKA) revision surgery. Summary of background data Prosthetic wear debris leading to particle disease, followed by osteolysis, is often observed after THA and TKA. Although the presence of polyethylene (PE) particles and periprosthetic inflammation after TDR has been proven recently, osteolysis is rarely observed. The clinical relevance of PE wear debris in the spine remains poorly understood. Methods Number, size and shape of PE particles, as well as quantity and type of inflammatory cells in periprosthetic tissue retrieved during Charité TDR (n=22), THA (n=10) and TKA (n=4) revision surgery were compared. Tissue samples were stained with hematoxylin/eosin and examined by using light microscopy with bright field and polarized light. Results After THA, large numbers of PE particles <6 µm were observed, which were mainly phagocytosed by macrophages. The TKA group had a broad size range with many larger PE particles and more giant cells. In TDR, the size range was similar to that observed in TKA. However, the smallest particles were the most prevalent with 75% of the particles being <6 µm, as seen in revision THA. In TDR, both macrophages and giant cells were present with a higher number of macrophages. Conclusions Both small and large PE particles are present after TDR revision surgery compatible with both THA and TKA wear patterns. The similarities between periprosthetic tissue reactions in the different groups may give more insight in the clinical relevance of PE particles and inflammatory cells in the lumbar spine. The current findings may help to improve TDR design as applied from technologies previously developed in THA and TKA with the goal of a longer survival of TDR. PMID:21336235
Third-generation pure alumina and alumina matrix composites in total hip arthroplasty
Hannouche, Didier; Zingg, Matthieu; Miozzari, Hermes; Nizard, Remy; Lübbeke, Anne
2018-01-01
Wear, corrosion and periprosthetic osteolysis are important causes of failure in joint arthroplasty, especially in young patients. Ceramic bearings, developed 40 years ago, are an increasingly popular choice in hip arthroplasty. New manufacturing procedures have increased the strength and reliability of ceramic materials and reduced the risk of complications. In recent decades, ceramics made of pure alumina have continuously improved, resulting in a surgical-grade material that fulfills clinical requirements. Despite the track record of safety and long-term results, third-generation pure alumina ceramics are being replaced in clinical practice by alumina matrix composites, which are composed of alumina and zirconium. In this review, the characteristics of both materials are discussed, and the long-term results with third-generation alumina-on-alumina bearings and the associated complications are compared with those of other available ceramics. Cite this article: EFORT Open Rev 2018;3:7-14. DOI: 10.1302/2058-5241.3.170034 PMID:29657840
The design and development of a triaxial wear-testing joint simulator.
Green, A S; O'Connell, M K; Lyons, A S; James, S P
1999-01-01
Most of the existing wear testers created to wear test total hip replacements, specifically the acetabular component, are designed to exert only an axial force and provide rotation in a close approximation of the actual femoral movement. The Rocky Mountain Joint Simulator was designed to exert three orthogonal forces and provide rotations about the X-, Y- and Z-axes to more closely simulate the physiological forces and motions found in the human gait cycle. The RMJS was also designed with adaptability for other joints, such as knees or canine hips, through the use of hydraulics and a computer-programmable control system. Such adaptability and functionality allows the researcher to more closely model a gait cycle, thereby obtaining wear patterns that resemble those found in retrieved implants more closely than existing simulators. Research is ongoing into the tuning and evaluation of the machine and preliminary acetabular component wear test results will be presented at the conference.
Febrile response after knee and hip arthroplasty.
Shaw, J A; Chung, R
1999-10-01
Documentation of the normal fever response after total knee and hip replacement is important to avoid an unnecessary workup for sepsis, and to provide justification for early discharge (dictated by the current medical reimbursement climate) despite persistent postoperative fever. One hundred patients who underwent total knee arthroplasty and 100 patients who underwent total hip arthroplasty were reviewed, several of whom had extensive sepsis workups for evaluation of postoperative fever. No patient in this series had a documented joint infection. All patients were treated with warfarin for deep vein thombrosis prophylaxis. All patients used incentive spirometry and were started on ambulation training on postoperative Day 1. All were given antibiotic prophylaxis for 48 hours. The maximum daily postoperative temperature occurred in most patients on postoperative Day 1 and gradually leveled off toward normal by postoperative Day 5. Only one patient had a maximum temperature on postoperative Day 4 that was greater than that on postoperative Day 3. Patients undergoing revision procedures tended to have a more pronounced febrile response, but the differences were not statistically significant. No significant differences were seen between patients who had epidural anesthesia and patients who had general anesthesia. Seventeen patients had postoperative chest radiographs for evaluation of fever. None had significant atelectasis. The presence of a positive urine culture had no effect on the fever response, with most positive results being identified after the fever had returned toward normal. Postoperative fever after total joint arthroplasty is a normal inflammatory response. A workup for sepsis is not indicated in the perioperative period unless corroborating signs or symptoms are present. Early discharge is appropriate if the febrile response is decreasing progressively.
Segregation for reduction of regulated medical waste in the operating room: a case report
Shinn, Helen Ki; Kim, Byung-Gun; Yang, Chunwoo; Na, WonJu; Song, Jang-Ho
2017-01-01
One-third of all hospital-regulated medical waste (RMW) comes from the operating room (OR), and it considerably consists of disposable packaging and wrapping materials for the sterilization of surgical instruments. This study sought to identify the amount and type of waste produced by ORs in order to reduce the RMW so as to achieve environmentally-friendly waste management in the OR. We performed an initial waste segregation of 4 total knee replacement arthroplasties (TKRAs) and 1 total hip replacement arthroplasty, and later of 1 extra TKRA, 1 laparoscopic anterior resection of the colon, and 1 pelviscopy (with radical vaginal hysterectomy), performed at our OR. The total mass of non-regulated medical waste (non-RMW) and blue wrap amounted to 30.5 kg (24.9%), and that of RMW to 92.1 kg (75.1%). In the course of the study, we noted that the non-RMW included recyclables, such as papers, plastics, cardboards, and various wrapping materials. The study showed that a reduction in RMW generation can be achieved through the systematic segregation of OR waste. PMID:28184276
Hip rotation range of motion in sitting and prone positions in healthy Japanese adults
Han, Heonsoo; Kubo, Akira; Kurosawa, Kazuo; Maruichi, Shizuka; Maruyama, Hitoshi
2015-01-01
[Purpose] The aim of this study was to elucidate the difference in hip external and internal rotation ranges of motion (ROM) between the prone and sitting positions. [Subjects] The subjects included 151 students. [Methods] Hip rotational ROM was measured with the subjects in the prone and sitting positions. Two-way repeated measures analysis of variance (ANOVA) was used to analyze ipsilateral hip rotation ROM in the prone and sitting positions in males and females. The total ipsilateral hip rotation ROM was calculated by adding the measured values for external and internal rotations. [Results] Ipsilateral hip rotation ROM revealed significant differences between two positions for both left and right internal and external rotations. Hip rotation ROM was significantly higher in the prone position than in the sitting position. Hip rotation ROM significantly differed between the men and women. Hip external rotation ROM was significantly higher in both positions in men; conversely, hip internal rotation ROM was significantly higher in both positions in women. [Conclusion] Hip rotation ROM significantly differed between the sexes and between the sitting and prone positions. Total ipsilateral hip rotation ROM, total angle of external rotation, and total angle of internal rotation of the left and right hips greatly varied, suggesting that hip joint rotational ROM is widely distributed. PMID:25729186
DOE Office of Scientific and Technical Information (OSTI.GOV)
Healy, W.L.; Lo, T.C.; Covall, D.J.
1990-12-01
Single-dose radiation therapy was prospectively evaluated for its efficacy in prevention of heterotopic ossification in patients at high risk after total hip arthroplasty. Thirty-one patients (34 hips) were treated between 1981 and 1988. Risk factors for inclusion in the protocol included prior evidence of heterotopic ossification, ankylosing spondylitis, and diffuse idiopathic skeletal hyperostosis. Patients with hypertrophic osteoarthritis or traumatic arthritis with osteophytes were not included. Operations on 34 hips included 19 primary total and 11 revision total hip arthroplasties and 4 excisions of heterotopic ossification. All patients received radiotherapy to the hip after operation with a single dose of 700more » centigray. Radiotherapy is recommended on the first postoperative day. After this single-dose radiation treatment, no patient had clinically significant heterotopic ossification. Recurrent disease developed in two hips (6%), as seen on radiography (grades 2 and 3). This series documents a 100% clinical success rate and a 94% radiographic success rate in preventing heterotopic ossification in patients at high risk after total hip arthroplasty. Single-dose radiotherapy is as effective as other radiation protocols in preventing heterotopic ossification after total hip arthroplasty. It is less expensive and easier to administer than multidose radiotherapy.« less
Ramos, A; Duarte, R J; Relvas, C; Completo, A; Simões, J A
2013-07-01
The press-fit hip acetabular prosthesis implantation can cause crack formation in the thin regions surrounding the acetabular. As a consequence the presence of cracks in this region can lead to poor fixation and fibrous tissue formation. Numerical and experimental models of commercial press-fit hip replacements were developed to compare the behavior between the intact and implanted joints. Numerical models with an artificial crack and without crack were considered. The iliac and the femur were created through 3D geometry acquisition based on composite human replicas and 3D-Finite Element models were generated. The mechanical behavior was assessed numerically and experimentally considering the principal strains. The comparison between Finite Element model predictions and experimental measurements revealed a maximum difference of 9%. Similar distribution of the principal strains around the acetabular cavity was obtained for the intact and implanted models. When comparing the Von Mises stresses, it is possible to observe that the intact model is the one that presents the highest stress values in the entire acetabular cavity surface. The crack in the posterior side changes significantly the principal strain distribution, suggesting bone loss after hip replacement. Relatively to micromotions, these were higher on the superior side of the acetabular cavity and can change the implant stability and bone ingrowth. Copyright © 2013 Elsevier Ltd. All rights reserved.
Atchabahian, Arthur; Schwartz, Gary; Hall, Charles B; Lajam, Claudette M; Andreae, Michael H
2015-01-01
Background Regional analgesia is more effective than conventional analgesia for controlling pain and may facilitate rehabilitation after large joint replacement in the short term. It remains unclear if regional anaesthesia improves functional outcomes after joint replacement beyond three months after surgery. Objectives To assess the effects of regional anaesthesia and analgesia on long-term functional outcomes 3, 6 and 12 months after elective major joint (knee, shoulder and hip) replacement surgery. Search methods We performed an electronic search of several databases (CENTRAL, MEDLINE, EMBASE, CINAHL), and handsearched reference lists and conference abstracts. We updated our search in June 2015. Selection criteria We included randomized controlled trials (RCTs) comparing regional analgesia versus conventional analgesia in patients undergoing total shoulder, hip or knee replacement. We included studies that reported a functional outcome with a follow-up of at least three months after surgery. Data collection and analysis We used standard methodological procedures expected by Cochrane. We contacted study authors for additional information. Main results We included six studies with 350 participants followed for at least three months. All of these studies enrolled participants undergoing total knee replacement. Studies were at least partially blinded. Three studies had a high risk of performance bias and one a high risk of attrition bias, but the risk of bias was otherwise unclear or low. Only one study assessed joint function using a global score. Due to heterogeneity in outcome and reporting, we could only pool three out of six RCTs, with range of motion assessed at three months after surgery used as a surrogate for joint function. All studies had a high risk of detection bias. Using the random-effects model, there was no statistically significant difference between the experimental and control groups (mean difference 3.99 degrees, 95% confidence interval (CI) − 2.23 to 10.21; P value = 0.21, 3 studies, 140 participants, very low quality evidence). We did not perform further analyses because immediate adverse effects were not part of the explicit outcomes of any of these typically small studies, and long-term adverse events after regional anaesthesia are rare. None of the included studies elicited or reported long-term adverse effects like persistent nerve damage. Authors’ conclusions More high-quality studies are needed to establish the effects of regional analgesia on function after major joint replacement, as well as on the risk of adverse events (falls). PMID:26269416
Gualtierotti, Roberta; Parisi, Marco; Ingegnoli, Francesca
2018-04-01
Patients with inflammatory rheumatic diseases often need orthopaedic surgery due to joint involvement. Total hip replacement and total knee replacement are frequent surgical procedures in these patients. Due to the complexity of the inflammatory rheumatic diseases, the perioperative management of these patients must envisage a multidisciplinary approach. The frequent association with extraarticular comorbidities must be considered when evaluating perioperative risk of the patient and should guide the clinician in the decision-making process. However, guidelines of different medical societies may vary and are sometimes contradictory. Orthopaedics should collaborate with rheumatologists, anaesthesiologists and, when needed, cardiologists and haematologists with the common aim of minimising perioperative risk in patients with inflammatory rheumatic diseases. The aim of this review is to provide the reader with simple practical recommendations regarding perioperative management of drugs such as disease-modifying anti-rheumatic drugs, corticosteroids, non-steroidal anti-inflammatory drugs and tools for a risk stratification for cardiovascular and thromboembolic risk based on current evidence for patients with inflammatory rheumatic diseases.
Metal-on-Metal Hip Resurfacing Arthroplasty
Sehatzadeh, S; Kaulback, K; Levin, L
2012-01-01
Background Metal-on-metal (MOM) hip resurfacing arthroplasty (HRA) is in clinical use as an appropriate alternative to total hip arthroplasty in young patients. In this technique, a metal cap is placed on the femoral head to cover the damaged surface of the bone and a metal cup is placed in the acetabulum. Objectives The primary objective of this analysis was to compare the revision rates of MOM HRA using different implants with the benchmark set by the National Institute of Clinical Excellence (NICE). The secondary objective of this analysis was to review the literature regarding adverse biological effects associated with implant material. Review Methods A literature search was performed on February 13, 2012, to identify studies published from January 1, 2009, to February 13, 2012. Results The revision rates for MOM HRA using 6 different implants were reviewed. The revision rates for MOM HRA with 3 implants met the NICE criteria, i.e., a revision rate of 10% or less at 10 years. Two implants had short-term follow-ups and MOM HRA with one of the implants failed to meet the NICE criteria. Adverse tissue reactions resulting in failure of the implants have been reported by several studies. With a better understanding of the factors that influence the wear rate of the implants, adverse tissue reactions and subsequent implant failure can be minimized. Many authors have suggested that patient selection and surgical technique affect the wear rate and the risk of tissue reactions. The biological effects of high metal ion levels in the blood and urine of patients with MOM HRA implants are not known. Studies have shown an increase in chromosomal aberrations in patients with MOM articulations, but the clinical implications and long-term consequences of this increase are still unknown. Epidemiological studies have shown that patients with MOM HRA implants did not have an overall increase in mortality or risk of cancer. There is insufficient clinical data to confirm the teratogenicity of MOM implants in humans. Conclusions Metal-on-metal HRA can be beneficial for appropriately selected patients, provided the surgeon has the surgical skills required for performing this procedure. Plain Language Summary There are many young patients with hip diseases who need to have hip replacement surgery. Although a traditional hip replacement is an acceptable procedure for these patients, some surgeons prefer using a newer technique in young patients called hip resurfacing. In this technique, instead of removing the head of the femoral bone, a metal cap is placed on the femoral head to cover the damaged surface of the bone and a metal cup is placed in the hip socket, similar to the cups used in traditional hip replacement. The analysis of the revision rates (i.e., how soon and in how many patients the surgery needs to be redone) and safety of resurfacing implants showed that generally these implants can last 10 years or more for the majority of young people. Good outcomes can be expected when skilled surgeons perform the surgery in properly selected patients. However, since these implants are made of metal (cobalt and chromium alloy), there is concern about excess metal debris production due to friction between the 2 metal components leading to high levels of metal ions in the blood and urine of patients. The production of metal debris may result in inflammation in the joint or development of a benign soft tissue mass leading to implant failure. However, it has been shown that this risk can be reduced by proper positioning of the implant and the careful selection of patients for this procedure. Little is known about the long-term biological effects of high levels of metal ions in the blood and urine of patients who have received metal implants. There is concern about potential increases in the risk of cancer and the risk of fetal abnormalities, but these effects have not been established yet. However, since cobalt and chromium can pass the placental barrier, implants that are not metal-on-metal are recommended for women at childbearing ages if they need a hip replacement. PMID:23074429
Thienpont, E; Vanden Berghe, A; Schwab, P E; Forthomme, J P; Cornu, O
2016-10-01
To utilize the 'Forgotten Joint' Score (FJS), a 12-item questionnaire analysing the ability to forget the joint, for comparing preoperative status in osteoarthritic patients scheduled for total hip arthroplasty (THA) or total knee arthroplasty (TKA). Higher scores represent a better result with a maximum of 100. The hypothesis of this study was that a preoperative difference in favour of hip arthritis could eventually explain why THA is cited more often as a forgotten joint than TKA. A prospective cohort study was conducted in 150 patients with either tricompartmental knee (n = 75) or hip osteoarthritis (n = 75). Patients completed FJS-12 scores preoperatively and 1 year postoperatively. A similar preoperative FJS-12 was observed for hip (22 (15)) and knee osteoarthritis (24 (17)) (n.s.). The postoperative FJS-12 score was significantly higher for THA (80 (24)) than for TKA (70 (27)) (p < 0.05). High reliability after 6 weeks was observed for the preoperative FJS-12 test-retest reliability (ICC = 0.87) in TKA. A preoperative floor effect of 15 % in THA and 0 % in TKA was found as well as a postoperative ceiling effect of 33 % in THA and 9 % in TKA. The clinical relevance of utilizing the FJS-12 as an instrument to evaluate outcome is strongly proposed for knee arthroplasty. In general, one is not aware of a healthy joint during the ADL, and it can therefore be regarded as 'forgotten'. The preoperative FJS-12 Score is a powerful tool to provide patients with clearer insights into their positive evolution after surgery. The use of the FJS-12 in THA is a topic for further research, as this study found that floor and ceiling effects limit its usefulness in studies evaluating clinical outcome in this area. II.
Periprosthetic hip fractures: A review of the economic burden based on length of stay.
Lyons, Rebecca F; Piggott, Robert P; Curtin, William; Murphy, Colin G
2018-03-01
With the increasing rates of total hip replacements being performed worldwide, there is an increasing incidence of periprosthetic fractures. As our patients' demographics change to include older patients with multiple medical co-morbidities, there is a concurrent increase in morbidity and mortality rates. This leads to longer hospital stays and increasing hospital costs. In the current economic climate, the cost of treating periprosthetic fractures must be addressed and appropriate resource and funding allocation for future provision of services should be planned. All periprosthetic hip fractures that were admitted to a single trauma unit over a three-year period were reviewed. Independent chart review, haematological and radiological review was undertaken. All patients with a periprosthetic fracture associated with a total hip arthroplasty or hemiarthroplasty were included. Follow up data including complications were collated. Data from the hospital inpatient database and finance department was utilized for cost analysis. All statistical analysis was preformed using Minitab version 17. 48 patients were identified who met the inclusion criteria for review. The majority of participants were female with a mean age of 73.5 years. The mean time to fracture was 4.5 years (9 months-18.5 years). Periprosthetic fracture was associated with total hip arthroplasty in 24 cases and a Vancouver B2 classification was most common at n = 20. The majority of patients had revision arthroplasty, with a mean length of stay of 24 days for the whole cohort (9-42). Vancouver B3 fractures had the longest inpatient stay at a mean of 26 days. The mean cost of for a full revision of stem with additional plate and cable fixation was over €27000 compared to €14,600 for ORIF and cable fixation based on length of hospital stay. The prolonged length of stay associated with Vancouver B2 and B3 fractures leads to increased costs to the healthcare service. Accurately calculating the costs of total treatment for periprosthetic fractures is difficult due to a lack of transparency around implant and staffing costs. However, as we can expect increasing incidence of periprosthetic fractures presenting in the coming years it is paramount that we make financial provisions within healthcare budgets to ensure we can treat these patients appropriately.
Position of the prosthesis and the incidence of dislocation following total hip replacement.
He, Rong-xin; Yan, Shi-gui; Wu, Li-dong; Wang, Xiang-hua; Dai, Xue-song
2007-07-05
Dislocation is the second most common complication of hip replacement surgery, and impact of the prosthesis is believed to be the fundamental reason. The present study employed Solidworks 2003 and MSC-Nastran software to analyze the three dimensional variables in order to investigate how to prevent dislocation following hip replacement surgery. Computed tomography (CT) imaging was used to collect femoral outline data and Solidworks 2003 software was used to construct the cup model with variabilities. Nastran software was used to evaluate dislocation at different prosthesis positions and different geometrical shapes. Three dimensional movement and results from finite element method were analyzed and the values of dislocation resistance index (DRI), range of motion to impingement (ROM-I), range of motion to dislocation (ROM-D) and peak resisting moment (PRM) were determined. Computer simulation was used to evaluate the range of motion of the hip joint at different prosthesis positions. Finite element analysis showed: (1) Increasing the ratio of head/neck increased the ROM-I values and moderately increased ROM-D and PRM values. Increasing the head size significantly increased PRM and to some extent ROM-I and ROM-D values, which suggested that there would be a greater likelihood of dislocation. (2) Increasing the anteversion angle increased the ROM-I, ROM-D, PRM, energy required for dislocation (ENERGY-D) and DRI values, which would increase the stability of the joint. (3) As the chamber angle was increased, ROM-I, ROM-D, PRM, Energy-D and DRI values were increased, resulting in improved joint stability. Chamber angles exceeding 55 degrees resulted in increases in ROM-I and ROM-D values, but decreases in PRM, Energy-D, and DRI values, which, in turn, increased the likelihood of dislocation. (4) The cup, which was reduced posteriorly, reduced ROM-I values (2.1 -- 5.3 degrees ) and increased the DRI value (0.073). This suggested that the posterior high side had the effect of 10 degrees anteversion angle. Increasing the head/neck ratio increases joint stability. Posterior high side reduced the range of motion of the joint but increased joint stability; Increasing the anteversion angle increases DRI values and thus improve joint stability; Increasing the chamber angle increases DRI values and improves joint stability. However, at angles exceeding 55 degrees , further increases in the chamber angle result in decreased DRI values and reduce the stability of the joint.
[Case-control study on methods of limb length control in hip arthroplasty].
Zhang, Yang-yang; Zuo, Jian-lin; Gao, Zhong-li
2016-02-01
To introduce a new measuring tool for measuring postoperative limb length exactly, and to provide a convenient and effective method to control limb length after total hip replacement. From January 2013 to September 2014, 102 patients undergoing primary unilateral hip replacement were divided into two groups: experimental group and control group. There were 51 patients in the experimental group, including 25 males and 26 females, ranging in age from 37 to 92 years old, with an average of 60.41 years old. The patients in experimental group were treated with new method to control limb length. Other 51 patients in the control group, including 27 males and 24 females, ranging in age from 35 to 87 years old, with an average of 61.00 years old. The patients in the control group were treated with normal methods such as shuck test or limb touching. All the patients were operated by the same experienced surgeon. In the experimental group,total hip arthroplasties (THA) were performed on 35 patients with avascular necrosis of the femoral head or femoral neck fracture, and 16 patients were treated with hemiarthroplasty (HA). In the control group, 38 patients received THA and 13 patients received HA. On the anterior-posterior X-ray radiograph, several indexes were measured as follows: the distance of bilateral femoral offset (a), the height from tip of great trochanter to the rotation center of the femoral head (b) and the vertical distance between the top of the minor trochanter and the two tear drops line (c). The leg length discrepancy can be assessed with three parameters as follows: d1, the absolute value of the difference between the bilateral a values; d2, the difference between the bilateral b values; d3, the difference between the bilateral c values. The SPSS 21.0 was applied for the statistical analysis. In the experimental and control groups, d1 were 4.49 mm and 7.32 mm (P = 0.013); d2 were 2.37 mm and 4.32 mm (P = 0.033); d3 were 3.32 mm and 6.08 mm (P = 0.031). The values of d1, d2 and d3 in the experimental group were significant smaller than those in the control group. The new measuring tool and method can be used to control the limb length and offset effectively during operation.
Improta, Giovanni; Balato, Giovanni; Romano, Maria; Carpentieri, Francesco; Bifulco, Paolo; Alessandro Russo, Mario; Rosa, Donato; Triassi, Maria; Cesarelli, Mario
2015-08-01
In 2012, health care spending in Italy reached €114.5 billion, accounting for 7.2% of the Gross Domestic Product (GDP) and 14.2% of total public spending. Therefore, reducing waste in health facilities could generate substantial cost savings. The objective of this study is to show that Lean Six Sigma represents an appropriate methodology for the development of a clinical pathway which allows to improve quality and to reduce costs in prosthetic hip replacement surgery. The methodology used for the development of a new clinical pathway was Lean Six Sigma. Problem solving in Lean Six Sigma is the DMAIC (Define, Measure, Analyse, Improve, Control) roadmap, characterized by five operational phases which make possible to reach fixed goals through a rigorous process of defining, measuring, analysing, improving and controlling business problems. The following project indicated several variables influencing the inappropriate prolongation of the length of stay for inpatient treatment and corrective actions were performed to improve the effectiveness and efficiency of the process of care. The average length of stay was reduced from 18.9 to 10.6 days (-44%). This article shows there is no trade-off between quality and costs: Lean Six Sigma improves quality and, at the same time, reduces costs. © 2015 John Wiley & Sons, Ltd.
Microscopical analysis of synovial fluid wear debris from failing CoCr hip prostheses
NASA Astrophysics Data System (ADS)
Ward, M. B.; Brown, A. P.; Cox, A.; Curry, A.; Denton, J.
2010-07-01
Metal on metal hip joint prostheses are now commonly implanted in patients with hip problems. Although hip replacements largely go ahead problem free, some complications can arise such as infection immediately after surgery and aseptic necrosis caused by vascular complications due to surgery. A recent observation that has been made at Manchester is that some Cobalt Chromium (CoCr) implants are causing chronic pain, with the source being as yet unidentified. This form of replacement failure is independent of surgeon or hospital and so some underlying body/implant interface process is thought to be the problem. When the synovial fluid from a failed joint is examined particles of metal (wear debris) can be found. Transmission Electron Microscopy (TEM) has been used to look at fixed and sectioned samples of the synovial fluid and this has identified fine (< 100 nm) metal and metal oxide particles within the fluid. TEM EDX and Electron Energy Loss Spectroscopy (EELS) have been employed to examine the composition of the particles, showing them to be chromium rich. This gives rise to concern that the failure mechanism may be associated with the debris.
Hussey, Daniel K; Madanat, Rami; Donahue, Gabrielle S; Rolfson, Ola; Muratoglu, Orhun K; Malchau, Henrik
2016-01-01
Background and purpose Blood metal ion levels can be an indicator for detecting implant failure in metal-on-metal (MoM) hip arthroplasties. Little is known about the effect of bilateral MoM implants on metal ion levels and patient-reported outcomes. We compared unilateral patients and bilateral patients with either an ASR hip resurfacing (HR) or an ASR XL total hip replacement (THR) and investigated whether cobalt or chromium was associated with a broad spectrum of patient outcomes. Patients and methods From a registry of 1,328 patients enrolled in a multicenter prospective follow-up of the ASR Hip System, which was recalled in 2010, we analyzed data from 659 patients (311 HR, 348 THR) who met our inclusion criteria. Cobalt and chromium blood metal ion levels were measured and a 21-item patient-reported outcome measures (PROMs) questionnaire was used mean 6 years after index surgery. Results Using a minimal threshold of ≥7 ppb, elevated chromium ion levels were found to be associated with worse health-related quality of life (HRQoL) (p < 0.05) and hip function (p < 0.05) in women. These associations were not observed in men. Patients with a unilateral ASR HR had lower levels of cobalt ions than bilateral ASR HR patients (p < 0.001) but similar levels of chromium ions (p = 0.09). Unilateral ASR XL THR patients had lower chromium and cobalt ion levels (p < 0.005) than bilateral ASR XL THR patients. Interpretation Chromium ion levels of ≥7 ppb were associated with reduced functional outcomes in female MoM patients. PMID:27459602
Sakai, Akinori; Oshige, Toshihisa; Zenke, Yukichi; Yamanaka, Yoshiaki; Nagaishi, Hitoshi; Nakamura, Toshitaka
2010-01-01
The aim of this study was to test the effect of unipedal standing exercise on bone mineral density (BMD) of the hip in postmenopausal women. Japanese postmenopausal women (n = 94) were assigned at random to an exercise or control group (no exercise). The 6-month exercise program consisted of standing on a single foot for 1 min per leg 3 times per day. BMD of the hip was measured by dual-energy X-ray absorptiometry. There was no significant difference in age and baseline hip BMD between the exercise group (n = 49) and control group (n = 45). Exercise did not improve hip BMD compared with the control group. Stepwise regression analysis identified old age as a significant determinant (p = 0.034) of increased hip total BMD at 6 months after exercise. In 31 participants aged >/=70 years, the exercise group (n = 20) showed significant increase in the values of hip BMD at the areas of total (p = 0.008), intertrochanteric (p = 0.023), and Ward's triangle (p = 0.032). The same parameters were decreased in the control group (n = 11). The percent changes in hip BMD of the exercise group were not significantly different from those of the control group either in the participants with low baseline hip total BMD (<80% of the young adult mean) or high baseline hip total BMD (> or =80% of the young adult mean). In conclusion, unipedal standing exercise for 6 months did not improve hip BMD in Japanese postmenopausal women. Effect of exercise on hip total BMD was age dependent. In participants aged > or =70 years, the exercise significantly increased hip total BMD.
Escobar, A; Quintana, J M; Bilbao, A; Azkárate, J; Güenaga, J I
2002-11-01
The aim of this study was to validate a translated version of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) questionnaire in Spanish patients with hip or knee osteoarthritis (OA). The WOMAC questionnaire and the SF-36 were administered to a sample of 269 patients on the waiting list for hip or knee replacement. We studied the convergent validity and the item-scale correlation using Pearson's correlation coefficient and Spearman's pi. For the reliability study we used another sample of 58 patients who received the WOMAC twice within 15 days. The Pearson's, Spearman's pi, and intraclass correlation coefficients were calculated. Internal consistency was measured by Cronbach's alpha. The responsiveness study was carried out by resending the two questionnaires to all patients 6 months after surgical intervention; responsiveness was measured by means of the paired t-test, the effect size I and the standardised response mean. The Pearson's coefficients for the convergent validity ranged from -0.52 to -0.63. The coefficients obtained for the item-scale correlation of the pain area were 0.74 or higher, 0.91 or higher for stiffness, and 0.61 or higher for function. When measuring the test-retest reliability, the coefficients ranged from 0.66 to 0.81. Internal consistency yielded a Cronbach's alpha ranging from 0.81 to 0.93. The responsiveness showed an effect size I ranging from 1.5 to 2.2 in patients who underwent hip replacement; for those who underwent knee replacement the range was 1 to 1.8. The standardised response mean ranged from 1.3 to 1.9 for patients with hip OA; those with knee OA ranged from 0.8 to 1.5. The Spanish version of WOMAC is a valid, reliable and responsive instrument in patients with hip or knee OA.
Hancock, Douglas S; Sharplin, Paul K; Larsen, Peter D; Phillips, Fredrick Ts
2018-05-01
To assess early radiological and functional outcomes of revision hip surgery with a cementless press-fit design femoral stem. A retrospective review of 48 consecutive revision total hip replacements using the RECLAIM revision hip system, between October 2012 and August 2015. Radiographic assessment was undertaken with serial anteroposterior (AP) X-rays of the pelvis. Risk factors for subsidence were evaluated. Prospective clinical follow up was performed on 21 patients to assess functional outcomes. Mean stem subsidence was 1.1 mm (95% confidence interval[CI]: 0.63-1.57). Median follow up of 12 months. An inverse relationship was observed between level of subsidence and femoral stem diameter r = -0.45, p = 0.001. Subsidence at the time of follow-up assessment was correlated with initial subsidence (correlation coefficient rho 0.69, p = 0.001). The mean Merle d'Aubigne score at the latest follow up was 14.2 (range 8-17). The mean OHS was 34.1 (range 15-48). Early radiological and functional outcomes for the RECLAIM revision system showed very low levels of subsidence and good functional outcomes. There was an association with smaller diameter femoral stems and greater levels of subsidence.
Trochanteric bursitis: the last great misnomer.
Board, Tim N; Hughes, Simon J; Freemont, Anthony J
2014-12-05
Trochanteric bursitis has been used as a general term to describe pain around the greater trochanteric region of the hip. We hypothesised that trochanteric bursitis may not however have an inflammatory component and that accordingly, bursal inflammation has no role in lateral hip pain. This study was designed to test this hypothesis. Patients undergoing primary total hip replacement were enrolled in this prospective, case-controlled, blinded study. Twenty-five patients who met the criteria for diagnosis of trochanteric bursitis (group A) were matched with a control group of 25 patients (group B). Trochanteric bursal samples were harvested from all patients intraoperatively and sent for histological analysis for the presence of inflammation. The intraoperative appearance of the abductor tendon insertion was also noted. None of the samples showed any evidence of acute or chronic inflammatory changes. Intraoperatively, five patients (20%) in group A were noted to have thinning of the gluteus medius tendon but no macroscopic tendon tears were detected in any bursal samples. This study suggests that there is no inflammatory component to so-called trochanteric bursitis, which accordingly casts doubt on both the terminology and the existence of this condition as a separate clinical entity. Clinicians should search for an alternative cause of symptoms in such cases.
Baser, Onur; Supina, Dylan; Sengupta, Nishan; Wang, Li; Kwong, Louis
2011-02-01
Venous thromboembolism (VTE) occurs most often during hospitalization for major surgery or trauma but may also occur up to several months after surgery. Since the potential for VTE exists in a range of clinical settings, an assessment of its impact on overall outcomes and costs to the patient and to the healthcare system is warranted. To evaluate the effects of VTE (deep vein thrombosis, pulmonary embolism, or both) occurring within the first 30 days of hospital discharge for total hip replacement (THR) or total knee replacement (TKR) surgery on inpatient costs, mortality, rehospitalization, and major bleeding within 1 year after initial hospitalization for THR or TKR surgery. The Medicare Provider Analysis and Review (MEDPAR) file for calendar years 2005-2007 provided hospital discharge abstracts for the fee-for-service, acute-care hospitalizations of all Medicare recipients. All patients included in the analysis underwent THR (n = 51,108) or TKR (n = 115,627). VTE events were diagnosed within the first 30 days and within 1 year post discharge. Propensity score matching was used to control for differences in baseline characteristics in patients with and without VTE events. Total cost was measured as Medicare cost plus beneficiary out-of-pocket cost. VTE occurred in 0.74% of patients undergoing THR. For patients with VTE versus no VTE, mortality was higher (2.9% vs 0.4%, P < 0.001) and rehospitalization within 1 year was more frequent (51.9% vs 22.4%, P < 0.001), as were complications such as bleeding (11.2% vs 2.7%, P < 0.001). Risk-adjusted Medicare cost and total healthcare cost, including beneficiary cost share in 1 year, were significantly higher for VTE patients versus patients with no VTE ($18,929 vs $3763, P < 0.001). VTE occurred in 0.70% of patients undergoing TKR. For patients with VTE versus no VTE, mortality was higher (2.5% vs 0.15%, P < 0.001), and rehospitalization within 1 year was more frequent (48.7% vs 20.7%, P < 0.001), as were complications such as bleeding (13.7% vs 2.1%, P < 0.001). For TKR surgery, risk-adjusted total healthcare cost, including beneficiary cost share in 1 year, was significantly different for VTE versus no VTE ($17,996 vs $4358, P < 0.001). Study limitations include a reliance on ICD-9-CM codes, which could be inaccurate, and the inability (1) to control for unmeasured confounders, such as surgeons' skills; (2) to include outpatient medical care costs; and (3) to ensure that all patients were enrolled continuously throughout the study period. VTE after THR or TKR is associated with higher mortality, rehospitalization, and bleeding within 1 year, compared with no VTE. Risk-adjusted total, Medicare, and beneficiary healthcare costs were significantly higher for both THR and TKR patients with VTE (P < 0.001).
Nelson, Mark; Bourke, Michael; Crossley, Kay; Russell, Trevor
2017-03-02
Total hip replacement (THR) is the gold standard treatment for severe hip osteoarthritis. Effectiveness of physical rehabilitation for THR patients following discharge from hospital is supported by evidence; however, barriers such as geographical location and transport can limit access to appropriate health care. One solution to this issue is using an alternative model of care using telerehabilitation technology to deliver rehabilitation programs directly into patients' homes. A telerehabilitation model may also have potential health care cost savings for health care providers. This study aims to determine if a telerehabilitation model of care delivered remotely is as effective as face-to-face rehabilitation in the THR population and cost effective for health care providers and patients. A total of 70 people undergoing THR will be recruited to participate in a randomized, single-blind, controlled noninferiority clinical trial. The trial will compare a technology-based THR rehabilitation program to in-person care. On discharge from hospital, participants randomized to the in-person group will receive usual care, defined as a paper home exercise program (HEP) targeting strengthening exercises for quadriceps, hip abductors, extensors, and flexors; they will be advised to perform their HEP 3 times per day. At 2, 4, and 6 weeks postoperatively, they will receive a 30-minute in-person physiotherapy session with a focus on gait retraining and reviewing and progressing their HEP. The telerehabilitation protocol will involve a program similar in content to the in-person rehabilitation program, except delivery will be directly into the homes of the participants via telerehabilitation technology on an iPad. Outcomes will be evaluated preoperatively, day of discharge from in-patient physiotherapy, 6 weeks and 6 months postoperatively. The primary outcome will be the quality of life subscale of the hip disability and osteoarthritis outcome score, measured at 6 weeks. Both intention-to-treat and per-protocol analyses as recommended in the extension of the Consolidated Standards for Reporting Trials (CONSORT) guideline for noninferiority trials will be performed. Recruitment commenced in September 2015 and is expected to be completed by June 2017. Data collection will be completed by December 2017. It is anticipated the results from this trial will be published by July 2018. Previous research investigating telerehabilitation in postoperative orthopedic conditions has yielded promising results. If shown to be as effective as in-person care, telerehabilitation after THR could be helpful in addressing access issues in this population. Furthermore, it may help reduce the cost of health care provision by enabling patients to take a more independent approach to their rehabilitation. Australian New Zealand Clinical Trials Registry ACTRN12615000824561; https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=364010 (Archived by WebCite at http://www.webcitation.org/6oWXweVfI). ©Mark Nelson, Michael Bourke, Kay Crossley, Trevor Russell. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 02.03.2017.