Sample records for total hip system

  1. Revision total hip arthroplasty due to pain from hypersensitivity to cobalt-chromium in total hip arthroplasty.

    PubMed

    Kosukegawa, Ima; Nagoya, Satoshi; Kaya, Mitsunori; Sasaki, Koichi; Sasaki, Mikito; Yamashita, Toshihiko

    2011-09-01

    We report a case with hypersensitivity to CoCr in total hip arthroplasty coupled with conventional polyethylene and CoCr femoral head. The patient complained of left hip pain and systemic fever, and computed tomography imaging revealed a periprosthetic cystic lesion, so we performed revision total hip arthroplasty using a titanium stem and ceramic head and highly crosslinked polyethylene. Hip pain and cystic lesion disappeared 3 years after revision surgery. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Primary total hip replacement for displaced subcapital fractures of the femur.

    PubMed

    Taine, W H; Armour, P C

    1985-03-01

    The management of displaced subcapital fracture of the hip is still controversial because of the high incidence of complications after internal fixation or hemiarthroplasty. To avoid some of these complications we have used primary total hip replacement for independently mobile patients over 65 years of age. A total of 163 cases, operated on over four years, have been reviewed. There were relatively more dislocations after operation for fracture than after total replacement for arthritis, and these were associated with a posterior approach to the hip. Only seven revision operations have been required. Of 57 patients who were interviewed an average of 42 months after replacement, 62% had excellent or good results as assessed by the Harris hip score. All the others had major systemic disease which affected their assessment. This inadequacy of current systems of hip assessment is discussed. It is concluded that total hip replacement is the best management for a selected group of patients with this injury, and that further prospective studies are indicated.

  3. Direct costs of osteoporosis and hip fracture: an analysis for the Mexican healthcare system.

    PubMed

    Clark, P; Carlos, F; Barrera, C; Guzman, J; Maetzel, A; Lavielle, P; Ramirez, E; Robinson, V; Rodriguez-Cabrera, R; Tamayo, J; Tugwell, P

    2008-03-01

    This study reports the direct costs related to osteoporosis and hip fractures paid for governmental and private institutions in the Mexican health system and estimates the impact of these entities on Mexico. We conclude that the economic burden due to the direct costs of hip fracture justifies wide-scale prevention programs for osteoporosis (OP). To estimate the total direct costs of OP and hip fractures in the Mexican Health care system, a sample of governmental and private institutions were studied. Information was gathered through direct questionnaires in 275 OP patients and 218 hip fracture cases. Additionally, a chart review was conducted and experts' opinions obtained to get accurate protocol scenarios for diagnoses and treatment of OP with no fracture. Microcosting and activity-based costing techniques were used to yield unit costs. The total direct costs for OP and hip fracture were estimated for 2006 based on the projected annual incidence of hip fractures in Mexico. A total of 22,233 hip fracture cases were estimated for 2006 with a total cost to the healthcare system of US$ 97,058,159 for the acute treatment alone ($4,365.50 per case). We found considerable differences in costs and the way the patients were treated across the different health sectors within the country. Costs of the acute treatment of hip fractures in Mexico are high and are expected to increase with the predicted increment of life expectancy and the number of elderly in our population.

  4. Novel cemented cup-holding technique while performing total hip arthroplasty with navigation system.

    PubMed

    Takai, Hirokazu; Takahashi, Tomoki

    2017-09-01

    Recently, navigation systems have been more widely utilized in total hip arthroplasty. However, almost all of these systems have been developed for cementless cups. In the case of cemented total hip arthroplasty using a navigation system, a special-ordered cemented holder is needed. We propose a novel cemented cup-holding technique for navigation systems using readily available articles. We combine a cementless cup holder with an inverted cementless trial cup. The resulting apparatus is used as a cemented cup holder. The upside-down cup-holding technique is useful and permits cemented cup users to utilize a navigation system for placement of the acetabular component.

  5. Total hip arthroplasty of dysplastic hip after previous Chiari pelvic osteotomy.

    PubMed

    Minoda, Yukihide; Kadowaki, Toru; Kim, Mitsunari

    2006-08-01

    Many reports have suggested that Chiari pelvic osteotomy would improve the results of acetabular component placement and fixation in subsequent total hip arthroplasty. However, little is known concerning the biomechanical, radiological, and clinical effects of Chiari pelvic osteotomy on subsequent total hip arthroplasty. Ten total hip arthroplasties for developmental dysplasia of the hip after previous Chiari pelvic osteotomy (Chiari group) were compared with 20 total hip arthroplasties for developmental dysplasia of the hip without previous surgery (control group). Preoperative patient demographic data and operative technique were well matched between the groups. The mean duration of follow-up was 3.0 years. Biomechanical, radiological, and clinical evaluations were performed. No acetabular or femoral components exhibited loosening. All patients had good or excellent clinical score according to the Merle d'Aubigne-Postel rating system at the most recent follow-up. Abductor force and joint force were smaller in the Chiari group, although long operative time, more blood loss, and verticalization of joint force were noted in this group. This limited study suggested that Chiari pelvic osteotomy changed the biomechanical features of the hip joint, and that this alteration might have compromised subsequent total hip arthroplasty.

  6. Medium-term results of ceramic-on-polyethylene Zweymüller-Plus total hip arthroplasty.

    PubMed

    Li, H; Zhang, S; Wang, X M; Lin, J H; Kou, B L

    2017-08-01

    The need for better durability and longevity in total hip arthroplasty for patients with various hip joint diseases remains a challenge. This study aimed to obtain medium-term results at a follow-up of >10 years for Zweymüller-Plus total hip arthroplasty with ceramic-on-polyethylene bearing. A retrospective study was conducted to review the results after a minimum of 12.4 years of 207 consecutive total hip arthroplasties in 185 patients in Peking University People's Hospital in China using the Zweymüller SL-Plus stem in combination with the Bicon-Plus threaded cup and ceramic-on-polyethylene bearing between October 1994 and April 2000. During the study period, two patients (2 hips) died and 25 patients (28 hips) were lost to follow-up. Two hips were revised for aseptic loosening of the Bicon-Plus cup. The mean clinical and radiological follow-up was 14.1 years (range, 12.4-16.5 years) for the remaining 156 patients (175 hips). The mean (standard deviation) Harris Hip score for the 175 hips increased significantly from 39.3 (3.8) preoperatively to 94.1 (2.5) postoperatively at a mean follow-up of 14.1 years (P<0.05). Focal osteolysis was observed in seven (4.0%) of 175 stems and three (1.7%) of 175 cups. The Kaplan-Meier survival with revision for any reason as the end-point was 99.03% (95% confidence interval, 95%-100%). The high survival rate of the cementless Zweymüller-Plus system with ceramic-on-polyethylene bearing at mid-term follow-up makes this total hip arthroplasty system reliable for patients with various hip joint diseases.

  7. Effects of preoperative physiotherapy in hip osteoarthritis patients awaiting total hip replacement

    PubMed Central

    Czyżewska, Anna; Walesiak, Katarzyna; Krawczak, Karolina; Cabaj, Dominika; Górecki, Andrzej

    2014-01-01

    Introduction The World Health Organization (WHO) claimed osteoarthritis as a civilization-related disease. The effectiveness of preoperative physiotherapy among patients suffering hip osteoarthritis (OA) at the end of their conservative treatment is rarely described in the literature. The aim of this study was to assess the quality of life and musculoskeletal health status of patients who received preoperative physiotherapy before total hip replacement (THR) surgery within a year prior to admission for a scheduled THR and those who did not. Material and methods Forty-five patients, admitted to the Department of Orthopaedics and Traumatology of Locomotor System for elective total hip replacement surgery, were recruited for this study. The assessment consisted of a detailed interview using various questionnaires: the Harris Hip Score (HHS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the 36-Item Short Form Health Survey (SF-36), and the Hip disability and Osteoarthritis Outcome Score (HOOS), as well as physical examination. Patients were assigned to groups based on their attendance of preoperative physiotherapy within a year prior to surgery. Results Among patients who received preoperative physiotherapy a significant improvement was found for pain, daily functioning, vitality, psychological health, social life, and (active and passive) internal rotation (p < 0.05). Conclusions Patients are not routinely referred to physiotherapy within a year before total hip replacement surgery. This study confirmed that pre-operative physiotherapy may have a positive influence on selected musculoskeletal system status indicators and quality of life in hip osteoarthritis patients awaiting surgery. PMID:25395951

  8. A Pilot Study of Augmented Reality Technology Applied to the Acetabular Cup Placement During Total Hip Arthroplasty.

    PubMed

    Ogawa, Hiroyuki; Hasegawa, Seiichirou; Tsukada, Sachiyuki; Matsubara, Masaaki

    2018-06-01

    We developed an acetabular cup placement device, the AR-HIP system, using augmented reality (AR). The AR-HIP system allows the surgeon to view an acetabular cup image superimposed in the surgical field through a smartphone. The smartphone also shows the placement angle of the acetabular cup. This preliminary study was performed to assess the accuracy of the AR-HIP system for acetabular cup placement during total hip arthroplasty (THA). We prospectively measured the placement angles using both a goniometer and AR-HIP system in 56 hips of 54 patients undergoing primary THA. We randomly determined the order of intraoperative measurement using the 2 devices. At 3 months after THA, the placement angle of the acetabular cup was measured on computed tomography images. The primary outcome was the absolute value of the difference between intraoperative and postoperative computed tomography measurements. The measurement angle using AR-HIP was significantly more accurate in terms of radiographic anteversion than that using a goniometer (2.7° vs 6.8°, respectively; mean difference 4.1°; 95% confidence interval, 3.0-5.2; P < .0001). There was no statistically significant difference in terms of radiographic inclination (2.1° vs 2.6°; mean difference 0.5°; 95% confidence interval, -1.1 to 0.1; P = .13). In this pilot study, the AR-HIP system provided more accurate information regarding acetabular cup placement angle than the conventional method. Further studies are required to confirm the utility of the AR-HIP system as a navigation tool. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. [Radiographic appraisal between metal and bone interosculate backfill after total hip arthroplasty with trabecular metal cup].

    PubMed

    Li, Wei; Zhou, Yi-Xin; Wu, Jian; Xu, Hui; Ji, Song-Jie

    2009-02-15

    To evaluate the bone refilling in the interface between the trabecular metal (TM) acetabular shell and the bone surface according to consecutive X film measuring after surgery. From July 2006 to July 2007, 35 patients (40 hips) accepted total hip replacement using trabecular metal monoblock acetabular cup system (TM). The cup was made of a ellipse shaped press fit Tantalum shell and high cross-linked PE liner (Longevity) with 28 mm inner diameter. The patients demography was: 16 male (20 hips), 19 female (20 hips), 5 bilateral hip replacements, age from 41 - 71 (mean 53), including 18 avascular necrosis hips, 16 osteoarthritis hips (including those secondary to a dysplasia hip), 4 avascular necrosis hips after femoral neck fracture, 2 Ankylosis Spondylitis. All the 40 total hip replacements used posterior approach, using hemispherical acetabular reamer and 2 mm press fit of final metal shell without screw fixation. The consecutive X film was taken at the end time of surgery and 2, 6, 12, 24 weeks, and 12 months. The clinical results was evaluate according to Harris scoring system, and the standard pelvis AP X film was measured at the interface between metal shell and the acetabular bone surface, witch was divided into five regions (A, B, C, D, E). Totally 32 patients (37 hips) were followed with average 8.7 months (7 - 12 months). The Harris before surgery was 50.5 (32 - 85), promoted to 91.0 (72 - 100), including 29 excellent, 6 good, 2 fair, and the total excellent and good rate was 94.6%. Complications include 4 patients leg length discrepancy from 1 - 2 cm, 3 patients moderate thigh pain and released after conservative therapy. No infection and dislocation was found. Twenty-one patients (23 hips) were found lucent line at the bone-metal interface from 1 - 5 mm, most common in B region and BC boundary than C, D, and CD boundary. All the patients followed was found the lucent line disappeared and refilled with bone at X film 24 weeks after surgery, however, no patients was found osteolysis and cup migration. The trabecular metal has strong capacity of bone conductive and bone inducement.

  10. Spine–hip relations in patients with hip osteoarthritis

    PubMed Central

    Rivière, Charles; Lazic, Stefan; Dagneaux, Louis; Van Der Straeten, Catherine; Cobb, Justin; Muirhead-Allwood, Sarah

    2018-01-01

    Patients with hip osteoarthritis often have an abnormal spine-hip relation (SHR), meaning the presence of a clinically deleterious spine-hip and/or hip-spine syndrome. Definition of the individual SHR is ideally done using the EOS® imaging system or, if not available, with conventional lumbopelvic lateral radiographs. By pre-operatively screening patients with abnormal SHR, it is possible to refine total hip replacement (THR) surgical planning, which may improve outcomes. An important component of the concept of kinematically aligned total hip arthroplasty (KA THA) consists of defining the optimal acetabular cup design and orientation based on the assessment of an individual’s SHR, and use of the transverse acetabular ligament to adjust the cup positioning. The Bordeaux classification might advance the understanding of SHR and hopefully help improve THR outcomes. Cite this article: EFORT Open Rev 2018;3:39-44. DOI: 10.1302/2058-5241.3.170020 PMID:29657844

  11. Canine total hip replacement using a cementless threaded cup and stem: a review of 55 cases.

    PubMed

    Denny, H R; Linnell, M; Maddox, T W; Comerford, E J

    2018-06-01

    To determine the long-term results and complications associated with the Helica ® cementless hip endoprosthesis system. Retrospective study of 55 consecutive Helica total hip replacements performed between January 2010 and February 2015. A total of 55 total hip replacements were performed in 50 dogs; 45 dogs had unilateral hip replacements, and five had staged bilateral replacements. A total of 23 first-generation short femoral stems were implanted in 22 dogs, of which nine cases (39%) experienced complications and 19 (86%) recovered satisfactorily when revisions were included; 31 second-generation femoral stems were implanted in 28 dogs, of which 10 cases (32%) experienced complications, and 26 (93%) made satisfactory recoveries, including revisions. In 36 dogs for which data were available, postoperative Liverpool Osteoarthritis in Dogs scores were significantly reduced compared to preoperative scores. Complications occurred in a total of 19 cases (34·5%; 95% confidence interval: 22 to 47·1%); the most common was aseptic loosening of the femoral stem [11 cases (20%; 95% confidence interval: 9·4 to 30·6%)]. Following multivariable analysis, no risk factors were identified for overall complications, but there was a significant association of implant type (first-generation short stem) with loosening (odds ratio 4·9, 95% confidence interval: 1·1 to 22·1, P=0·034). This study found the Helica hip endoprosthesis system to be effective in the management of hip dysplasia and osteoarthritis in dogs. Aseptic loosening of the femoral stem remains the most common complication but appears to have been significantly reduced with the introduction of the second-generation stem. © 2018 British Small Animal Veterinary Association.

  12. Total Hip Joint Replacement Biotelemetry System

    NASA Technical Reports Server (NTRS)

    Boreham, J. F.; Postal, R. B.; Luntz, R. A.

    1981-01-01

    The development of a biotelemetry system that is hermetically sealed within a total hip replacement implant is reported. The telemetry system transmits six channels of stress data to reconstruct the major forces acting on the neck of the prosthesis and uses an induction power coupling technique to eliminate the need for internal batteries. The activities associated with the telemetry microminiaturization, data recovery console, hardware fabrications, power induction systems, electrical and mechanical testing and hermetic sealing test results are discussed.

  13. Technical note: validation of a motion analysis system for measuring the relative motion of the intermediate component of a tripolar total hip arthroplasty prosthesis.

    PubMed

    Chen, Qingshan; Lazennec, Jean Yves; Guyen, Olivier; Kinbrum, Amy; Berry, Daniel J; An, Kai-Nan

    2005-07-01

    Tripolar total hip arthroplasty (THA) prosthesis had been suggested as a method to reduce the occurrence of hip dislocation and microseparation. Precisely measuring the motion of the intermediate component in vitro would provide fundamental knowledge for understanding its mechanism. The present study validates the accuracy and repeatability of a three-dimensional motion analysis system to quantitatively measure the relative motion of the intermediate component of tripolar total hip arthroplasty prostheses. Static and dynamic validations of the system were made by comparing the measurement to that of a potentiometer. Differences between the mean system-calculated angle and the angle measured by the potentiometer were within +/-1 degrees . The mean within-trial variability was less than 1 degrees . The mean slope was 0.9-1.02 for different angular velocities. The dynamic noise was within 1 degrees . The system was then applied to measure the relative motion of an eccentric THA prosthesis. The study shows that this motion analysis system provides an accurate and practical method for measuring the relative motion of the tripolar THA prosthesis in vitro, a necessary first step towards the understanding of its in vivo kinematics.

  14. Total hip arthroplasty in dwarfism. A case report.

    PubMed

    De Fine, Marcello; Traina, Francesco; Palmonari, Massimo; Tassinari, Enrico; Toni, Aldo

    2008-05-01

    In dwarfism hip arthritis, usually secondary to hip dysplasia, is a common finding at an early age. In these patients a joint replacement is a demanding procedure due to the peculiar joint deformity and the small size of the bones. We present a case of a bilateral hip replacement in a dwarf patient. In order to reduce intraoperative complications and improve the joint kinematics a thorough preoperative planning was performed by a CT based computerised system. On the basis of the planning we chose a conical shaped stem that enable as to restore limb length and offset with a low risk of femoral fracture. In conclusion, we consider total hip replacement in dwarfism a safe and effective procedure if an accurate preoperative planning is performed.

  15. Kinematic analysis of hip and knee rotation and other contributors to ballet turnout.

    PubMed

    Quanbeck, Amy E; Russell, Jeffrey A; Handley, Sara C; Quanbeck, Deborah S

    2017-02-01

    Turnout, or external rotation (ER) of the lower extremities, is essential in ballet. The purpose of this study was to utilise physical examination and a biomechanical method for obtaining functional kinematic data using hip and knee joint centres to identify the relative turnout contributions from hip rotation, femoral anteversion, knee rotation, tibial torsion, and other sources. Ten female dancers received a lower extremity alignment assessment, including passive hip rotation, femoral anteversion, tibial torsion, weightbearing foot alignment, and Beighton hypermobility score. Next, turnout was assessed using plantar pressure plots and three-dimensional motion analysis; participants performed turnout to ballet first position on both a plantar pressure mat and friction-reducing discs. A retro-reflective functional marker motion capture system mapped the lower extremities and hip and knee joint centres. Mean total turnout was 129±15.7° via plantar pressure plots and 135±17.8° via kinematics. Bilateral hip ER during turnout was 49±10.2° (36% of total turnout). Bilateral knee ER during turnout was 41±5.9° (32% of total turnout). Hip ER contribution to total turnout measured kinematically was less than expected compared to other studies, where hip ER was determined without functional kinematic data. Knee ER contributed substantially more turnout than expected or previously reported. This analysis method allows precise assessment of turnout contributors.

  16. Subsequent Total Joint Arthroplasty After Primary Total Knee or Hip Arthroplasty

    PubMed Central

    Sanders, Thomas L.; Maradit Kremers, Hilal; Schleck, Cathy D.; Larson, Dirk R.; Berry, Daniel J.

    2017-01-01

    Background: Despite the large increase in total hip arthroplasties and total knee arthroplasties, the incidence and prevalence of additional contralateral or ipsilateral joint arthroplasty are poorly understood. The purpose of this study was to determine the rate of additional joint arthroplasty after a primary total hip arthroplasty or total knee arthroplasty. Methods: This historical cohort study identified population-based cohorts of patients who underwent primary total hip arthroplasty (n = 1,933) or total knee arthroplasty (n = 2,139) between 1969 and 2008. Patients underwent passive follow-up through their medical records beginning with the primary total hip arthroplasty or total knee arthroplasty. We assessed the likelihood of undergoing a subsequent total joint arthroplasty, including simultaneous and staged bilateral procedures. Age, sex, and calendar year were evaluated as potential predictors of subsequent arthroplasty. Results: During a mean follow-up of 12 years after an initial total hip arthroplasty, we observed 422 contralateral total hip arthroplasties (29% at 20 years), 76 contralateral total knee arthroplasties (6% at 10 years), and 32 ipsilateral total knee arthroplasties (2% at 20 years). Younger age was a significant predictor of contralateral total hip arthroplasty (p < 0.0001), but not a predictor of the subsequent risk of total knee arthroplasty. During a mean follow-up of 11 years after an initial total knee arthroplasty, we observed 809 contralateral total knee arthroplasties (45% at 20 years), 31 contralateral total hip arthroplasties (3% at 20 years), and 29 ipsilateral total hip arthroplasties (2% at 20 years). Older age was a significant predictor of ipsilateral or contralateral total hip arthroplasty (p < 0.001). Conclusions: Patients undergoing total hip arthroplasty or total knee arthroplasty can be informed of a 30% to 45% chance of a surgical procedure in a contralateral cognate joint and about a 5% chance of a surgical procedure in noncognate joints within 20 years of initial arthroplasty. Increased risk of contralateral total knee arthroplasty following an initial total hip arthroplasty may be due to gait changes prior to and/or following total hip arthroplasty. The higher prevalence of bilateral total hip arthroplasty in younger patients may result from bilateral disease processes that selectively affect the young hip, such as osteonecrosis, or structural hip problems, such as acetabular dysplasia or femoroacetabular impingement. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. PMID:28244910

  17. Does bearing size influence metal ion levels in large-head metal-on-metal total hip arthroplasty? A comparison of three total hip systems

    PubMed Central

    2014-01-01

    Background The purpose of the study was twofold: first, to determine whether there is a statistically significant difference in the metal ion levels among three different large-head metal-on-metal (MOM) total hip systems. The second objective was to assess whether position of the implanted prostheses, patient demographics or factors such as activity levels influence overall blood metal ion levels and whether there is a difference in the functional outcomes between the systems. Methods In a cross-sectional cohort study, three different metal-on-metal total hip systems were assessed: two monoblock heads, the Durom socket (Zimmer, Warsaw, IN, USA) and the Birmingham socket (Smith and Nephew, Memphis, TN, USA), and one modular metal-on-metal total hip system (Pinnacle, Depuy Orthopedics, Warsaw, IN, USA). Fifty-four patients were recruited, with a mean age of 59.7 years and a mean follow-up time of 41 months (12 to 60). Patients were evaluated clinically, radiologically and biochemically. Statistical analysis was performed on all collected data to assess any differences between the three groups in terms of overall blood metal ion levels and also to identify whether there was any other factor within the group demographics and outcomes that could influence the mean levels of Co and Cr. Results Although the functional outcome scores were similar in all three groups, the blood metal ion levels in the larger monoblock large heads (Durom, Birmingham sockets) were significantly raised compared with those of the Pinnacle group. In addition, the metal ion levels were not found to have a statistically significant relationship to the anteversion or abduction angles as measured on the radiographs. Conclusions When considering a MOM THR, the use of a monoblock large-head system leads to higher elevations in whole blood metal ions and offers no advantage over a smaller head modular system. PMID:24472283

  18. Hip joint replacement

    MedlinePlus

    ... Total hip replacement; Hip hemiarthroplasty; Arthritis - hip replacement; Osteoarthritis - hip replacement ... total hip replacement surgery in patients with hip osteoarthritis: a long-term follow-up of a randomised ...

  19. Effect of screw fixation on acetabular component alignment change in total hip arthroplasty.

    PubMed

    Fujishiro, Takaaki; Hayashi, Shinya; Kanzaki, Noriyuki; Hashimoto, Shingo; Shibanuma, Nao; Kurosaka, Masahiro

    2014-06-01

    The use of screws can enhance immediate cup fixation, but the influence of screw insertion on cup position has not previously been measured. The purpose of this study was to quantitatively evaluate the effect of intra-operative screw fixation on acetabular component alignment that has been inserted with the use of a navigation system. We used a navigation system to measure cup alignment at the time of press-fit and after screw fixation in 144 hips undergoing total hip arthroplasty. We also compared those findings with factors measured from postoperative radiographs. The mean intra-operative change of cup position was 1.78° for inclination and 1.81° for anteversion. The intra-operative change of anteversion correlated with the number of screws. The intra-operative change of inclination also correlated with medial hip centre. The insertion of screws can induce changes in cup alignment, especially when multiple screws are used or if a more medial hip centre is required for rigid acetabular fixation.

  20. Computer-assisted hip and knee arthroplasty. Navigation and active robotic systems: an evidence-based analysis.

    PubMed

    2004-01-01

    The Medical Advisory Secretariat undertook a review of the evidence on the effectiveness and cost-effectiveness of computer assisted hip and knee arthroplasty. The two computer assisted arthroplasty systems that are the topics of this review are (1) navigation and (2) robotic-assisted hip and knee arthroplasty. Computer-assisted arthroplasty consists of navigation and robotic systems. Surgical navigation is a visualization system that provides positional information about surgical tools or implants relative to a target bone on a computer display. Most of the navigation-assisted arthroplasty devices that are the subject of this review are licensed by Health Canada. Robotic systems are active robots that mill bone according to information from a computer-assisted navigation system. The robotic-assisted arthroplasty devices that are the subject of this review are not currently licensed by Health Canada. The Cochrane and International Network of Agencies for Health Technology Assessment databases did not identify any health technology assessments on navigation or robotic-assisted hip or knee arthroplasty. The MEDLINE and EMBASE databases were searched for articles published between January 1, 1996 and November 30, 2003. This search produced 367 studies, of which 9 met the inclusion criteria. NAVIGATION-ASSISTED ARTHROPLASTY: Five studies were identified that examined navigation-assisted arthroplasty.A Level 1 evidence study from Germany found a statistically significant difference in alignment and angular deviation between navigation-assisted and free-hand total knee arthroplasty in favour of navigation-assisted surgery. However, the endpoints in this study were short-term. To date, the long-term effects (need for revision, implant longevity, pain, functional performance) are unknown.(1)A Level 2 evidence short-term study found that navigation-assisted total knee arthroplasty was significantly better than a non-navigated procedure for one of five postoperative measured angles.(2)A Level 2 evidence short-term study found no statistically significant difference in the variation of the abduction angle between navigation-assisted and conventional total hip arthroplasty.(3)Level 3 evidence observational studies of navigation-assisted total knee arthroplasty and unicompartmental knee arthroplasty have been conducted. Two studies reported that "the follow-up of the navigated prostheses is currently too short to know if clinical outcome or survival rates are improved. Longer follow-up is required to determine the respective advantages and disadvantages of both techniques."(4;5) ROBOTIC-ASSISTED ARTHROPLASTY: Four studies were identified that examined robotic-assisted arthroplasty.A Level 1 evidence study revealed that there was no statistically significant difference between functional hip scores at 24 months post implantation between patients who underwent robotic-assisted primary hip arthroplasty and those that were treated with manual implantation.(6)Robotic-assisted arthroplasty had advantages in terms of preoperative planning and the accuracy of the intraoperative procedure.(6)Patients who underwent robotic-assisted hip arthroplasty had a higher dislocation rate and more revisions.(6)Robotic-assisted arthroplasty may prove effective with certain prostheses (e.g., anatomic) because their use may result in less muscle detachment.(6)An observational study (Level 3 evidence) found that the incidence of severe embolic events during hip relocation was lower with robotic arthroplasty than with manual surgery.(7)An observational study (Level 3 evidence) found that there was no significant difference in gait analyses of patients who underwent robotic-assisted total hip arthroplasty using robotic surgery compared to patients who were treated with conventional cementless total hip arthroplasty.(8)An observational study (Level 3 evidence) compared outcomes of total knee arthroplasty between patients undergoing robotic surgery and patients who were historical controls. Brief, qualitative results suggested that there was much broader variation of angles after manual total knee arthroplasty compared to the robotic technique and that there was no difference in knee functional scores or implant position at the 3 and 6 month follow-up.(9).

  1. Computer-Assisted Hip and Knee Arthroplasty. Navigation and Active Robotic Systems

    PubMed Central

    2004-01-01

    Executive Summary Objective The Medical Advisory Secretariat undertook a review of the evidence on the effectiveness and cost-effectiveness of computer assisted hip and knee arthroplasty. The two computer assisted arthroplasty systems that are the topics of this review are (1) navigation and (2) robotic-assisted hip and knee arthroplasty. The Technology Computer-assisted arthroplasty consists of navigation and robotic systems. Surgical navigation is a visualization system that provides positional information about surgical tools or implants relative to a target bone on a computer display. Most of the navigation-assisted arthroplasty devices that are the subject of this review are licensed by Health Canada. Robotic systems are active robots that mill bone according to information from a computer-assisted navigation system. The robotic-assisted arthroplasty devices that are the subject of this review are not currently licensed by Health Canada. Review Strategy The Cochrane and International Network of Agencies for Health Technology Assessment databases did not identify any health technology assessments on navigation or robotic-assisted hip or knee arthroplasty. The MEDLINE and EMBASE databases were searched for articles published between January 1, 1996 and November 30, 2003. This search produced 367 studies, of which 9 met the inclusion criteria. Summary of Findings Navigation-Assisted Arthroplasty Five studies were identified that examined navigation-assisted arthroplasty. A Level 1 evidence study from Germany found a statistically significant difference in alignment and angular deviation between navigation-assisted and free-hand total knee arthroplasty in favour of navigation-assisted surgery. However, the endpoints in this study were short-term. To date, the long-term effects (need for revision, implant longevity, pain, functional performance) are unknown.(1) A Level 2 evidence short-term study found that navigation-assisted total knee arthroplasty was significantly better than a non-navigated procedure for one of five postoperative measured angles.(2) A Level 2 evidence short-term study found no statistically significant difference in the variation of the abduction angle between navigation-assisted and conventional total hip arthroplasty.(3) Level 3 evidence observational studies of navigation-assisted total knee arthroplasty and unicompartmental knee arthroplasty have been conducted. Two studies reported that “the follow-up of the navigated prostheses is currently too short to know if clinical outcome or survival rates are improved. Longer follow-up is required to determine the respective advantages and disadvantages of both techniques.”(4;5) Robotic-Assisted Arthroplasty Four studies were identified that examined robotic-assisted arthroplasty. A Level 1 evidence study revealed that there was no statistically significant difference between functional hip scores at 24 months post implantation between patients who underwent robotic-assisted primary hip arthroplasty and those that were treated with manual implantation.(6) Robotic-assisted arthroplasty had advantages in terms of preoperative planning and the accuracy of the intraoperative procedure.(6) Patients who underwent robotic-assisted hip arthroplasty had a higher dislocation rate and more revisions.(6) Robotic-assisted arthroplasty may prove effective with certain prostheses (e.g., anatomic) because their use may result in less muscle detachment.(6) An observational study (Level 3 evidence) found that the incidence of severe embolic events during hip relocation was lower with robotic arthroplasty than with manual surgery.(7) An observational study (Level 3 evidence) found that there was no significant difference in gait analyses of patients who underwent robotic-assisted total hip arthroplasty using robotic surgery compared to patients who were treated with conventional cementless total hip arthroplasty.(8) An observational study (Level 3 evidence) compared outcomes of total knee arthroplasty between patients undergoing robotic surgery and patients who were historical controls. Brief, qualitative results suggested that there was much broader variation of angles after manual total knee arthroplasty compared to the robotic technique and that there was no difference in knee functional scores or implant position at the 3 and 6 month follow-up.(9) PMID:23074452

  2. Outcome of total hip arthroplasty for avascular necrosis of the femoral head in systemic lupus erythematosus.

    PubMed

    Woo, Min Su; Kang, Joon Soon; Moon, Kyoung Ho

    2014-12-01

    This study evaluated the result of total hip arthroplasty (THA) for avascular necrosis of the femur head (AVNFH) in systemic lupus erythematosus (SLE) patients. Nineteen THAs were performed on 13 patients with SLE. The results of these patients were compared with the results of the control group (19 patients) who had THR due to AVNFH with none-SLE conditions. The Harris hip score increased from a preoperative average of 65.3 points to 94.9 at the most recent follow-up. In the control group, the mean HHS was 67.2 preoperatively and 96.1 postoperatively at the last follow-up. No significant difference was found between SLE patients and non-SLE patients who underwent hip arthroplasty. In conclusion, THA is an acceptable treatment for achieving functional improvement in patients who had SLE and AVNFH. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Patient Needs for an Ambulant Dislocation Alert System Following Total Hip Arthroplasty.

    PubMed

    Huis In't Veld, Rianne; Peters, Anil; Vollenbroek-Hutten, Miriam; Hermens, Hermie; van den Hoven, Carmen

    2018-05-01

    One of the major complications in total hip arthroplasty (THA) is dislocation of the prosthesis. To prevent early dislocation, patients are instructed with movement restrictions. The first goal in this development is to obtain insight in the movement restrictions that are reported to have low levels of self-efficacy during activities of daily life. The second goal is to reveal the design needs for an ambulant hip dislocation alert system (HipDas) and the third goal is to explore its usability among patients. Patient-centered experiences with THA were explored by the use of a questionnaire and a semistructured focus group. The questionnaire was administered among n = 32 THA patients at 1 week preoperative and at 3 and 6 weeks postoperative. The questions addressed self-efficacy, performance and effort expectancy, and usefulness and social influence. The focus group consisted of patient journeys and scenario composition. The usability of a prototype version of the HipDas system was evaluated (n = 5). Flexion of the hip >90°, bending over while sitting in a chair, and sleeping in a supine position are the restrictions that have the lowest self-efficacy. The majority of patients (>86.6%) believe that a future HipDas is useful. Focus group outcomes suggest there is a gradual decrease in the threshold for feedback. The system is preferably used in the first 6 weeks after surgery and appeared to be usable and highly clinically relevant. HipDas is considered an interesting concept that can accelerate functional recovery of patients following THA by providing support on how to properly apply postoperative movement restrictions to prevent a dislocation.

  4. Mortality After Total Knee and Total Hip Arthroplasty in a Large Integrated Health Care System.

    PubMed

    Inacio, Maria C S; Dillon, Mark T; Miric, Alex; Navarro, Ronald A; Paxton, Elizabeth W

    2017-01-01

    The number of excess deaths associated with elective total joint arthroplasty in the US is not well understood. To evaluate one-year postoperative mortality among patients with elective primary and revision arthroplasty procedures of the hip and knee. A retrospective analysis was conducted of hip and knee arthroplasties performed in 2010. Procedure type, procedure volume, patient age and sex, and mortality were obtained from an institutional total joint replacement registry. An integrated health care system population was the sampling frame for the study subjects and was the reference group for the study. Standardized 1-year mortality ratios (SMRs) and 95% confidence intervals (CIs) were calculated. A total of 10,163 primary total knee arthroplasties (TKAs), 4963 primary total hip arthroplasties (THAs), 606 revision TKAs, and 496 revision THAs were evaluated. Patients undergoing primary THA (SMR = 0.6, 95% CI = 0.4-0.7) and TKA (SMR = 0.4, 95% CI = 0.3-0.5) had lower odds of mortality than expected. Patients with revision TKA had higher-than-expected mortality odds (SMR = 1.8, 95% CI = 1.1-2.5), whereas patients with revision THA (SMR = 0.9, 95% CI = 0.4-1.5) did not have higher-than-expected odds of mortality. Understanding excess mortality after joint surgery allows clinicians to evaluate current practices and to determine whether certain groups are at higher-than-expected mortality risk after surgery.

  5. Mortality rates at 10 years after metal-on-metal hip resurfacing compared with total hip replacement in England: retrospective cohort analysis of hospital episode statistics

    PubMed Central

    Kendal, Adrian R; Prieto-Alhambra, Daniel; Arden, Nigel K; Judge, Andrew

    2013-01-01

    Objectives To compare 10 year mortality rates among patients undergoing metal-on-metal hip resurfacing and total hip replacement in England. Design Retrospective cohort study. Setting English hospital episode statistics database linked to mortality records from the Office for National Statistics. Population All adults who underwent primary elective hip replacement for osteoarthritis from April 1999 to March 2012. The exposure of interest was prosthesis type: cemented total hip replacement, uncemented total hip replacement, and metal-on-metal hip resurfacing. Confounding variables included age, sex, Charlson comorbidity index, rurality, area deprivation, surgical volume, and year of operation. Main outcome measures All cause mortality. Propensity score matching was used to minimise confounding by indication. Kaplan-Meier plots estimated the probability of survival up to 10 years after surgery. Multilevel Cox regression modelling, stratified on matched sets, described the association between prosthesis type and time to death, accounting for variation across hospital trusts. Results 7437 patients undergoing metal-on-metal hip resurfacing were matched to 22 311 undergoing cemented total hip replacement; 8101 patients undergoing metal-on-metal hip resurfacing were matched to 24 303 undergoing uncemented total hip replacement. 10 year rates of cumulative mortality were 271 (3.6%) for metal-on-metal hip resurfacing versus 1363 (6.1%) for cemented total hip replacement, and 239 (3.0%) for metal-on-metal hip resurfacing versus 999 (4.1%) for uncemented total hip replacement. Patients undergoing metal-on-metal hip resurfacing had an increased survival probability (hazard ratio 0.51 (95% confidence interval 0.45 to 0.59) for cemented hip replacement; 0.55 (0.47 to 0.65) for uncemented hip replacement). There was no evidence for an interaction with age or sex. Conclusions Patients with hip osteoarthritis undergoing metal-on-metal hip resurfacing have reduced mortality in the long term compared with those undergoing cemented or uncemented total hip replacement. This difference persisted after extensive adjustment for confounding factors available in our data. The study results can be applied to matched populations, which exclude patients who are very old and have had complex total hip replacements. Although residual confounding is possible, the observed effect size is large. These findings require validation in external cohorts and randomised clinical trials. PMID:24284336

  6. Comparison of two different rehabilitation programmes for thrust plate prosthesis: a randomized controlled study.

    PubMed

    Unver, Bayram; Karatosun, Vasfi; Gunal, Izge; Angin, Salih

    2004-02-01

    Weight bearing after total hip arthroplasty is postponed in order to prevent early loosening, but this negatively affects the rehabilitation programme. For the force transfer characteristics of thrust plate prosthesis (TPP), a new type of hip prosthesis used without cement is similar to the normal hip. We evaluated the possibilities of early weight bearing after TPP by comparing early partial with early full weight bearing. Randomized controlled study. Department of orthopaedics and traumatology in a university hospital. Sixty hips of 51 patients who underwent total hip arthroplasty with TPP were randomly assigned into two groups. Both groups received accelerated rehabilitation programmes: group 1 with early partial weight bearing and group 2 with early full weight bearing. Patients were evaluated by a blind observer preoperatively, at three months after surgery by clinical (measurement of range of hip motion (universal goniometry), muscle strength (Manual Muscle Test), functional test (6-minute walk test), hip function (Harris Hip Scoring System)) and radiographical parameters and one year after surgery by clinical (Harris Hip Scoring System) and radiographical parameters. Group 2 performed transfer activities earlier, had more walking distance at the time of discharge and shorter hospital stay than group 1. At three months, Harris Hip Score, muscle strength, 6-minute walk test, and duration of crutch use were significantly (p < 0.05) in favour of group 2. None of the patients in either group showed signs of loosening one year after the operation. These results suggest that patients with TPP can tolerate an accelerated rehabilitation programme with early weight bearing and will gain the goals of rehabilitation earlier.

  7. Comparison between topical and intravenous administration of tranexamic acid in primary total hip arthroplasty.

    PubMed

    Ueno, Masaya; Sonohata, Motoki; Fukumori, Norio; Kawano, Shunsuke; Kitajima, Masaru; Mawatari, Masaaki

    2016-01-01

    Tranexamic acid has been reported to be safer with topical administration than with intravenous administration in total knee arthroplasty. However, the most effective administration route of tranexamic acid in total hip arthroplasty remains controversial. This study compared the effectiveness of topical tranexamic acid administration with that of intravenous tranexamic acid administration in total hip arthroplasty. We retrospectively examined the medical records of 886 patients with osteoarthritis of the hip joint, who had undergone unilateral primary total hip arthroplasty. The patients were divided into a control group (n = 302; did not receive tranexamic acid), topical group (n = 265; topically administered 2 g tranexamic acid in 30 mL normal saline via drain tubes placed in the joint before wound closure along with posterior soft tissue repair), and intravenous group (n = 319; intravenously administered 1 g tranexamic acid before skin incision along with posterior soft tissue repair). Data on blood loss, hemoglobin levels, transfusion rates, and occurrence of deep vein thrombosis and pulmonary embolization were collected. The mean operation times were approximately 40 min in all of the groups. The operation time and intra-operative blood loss were significantly lower in the control group than in the topical and intravenous groups. However, the post-operative blood loss, total blood loss, and decrease in the hemoglobin level were significantly higher in the control group than in the topical and intravenous groups. There were no significant differences in terms of blood loss and systemic complications between the tranexamic acid administration methods. Tranexamic acid reduces both post-operative and total blood loss in total hip arthroplasty. Moreover, a lower amount of tranexamic acid can be used to reduce blood loss in total hip arthroplasty with intravenous tranexamic acid administration than with topical tranexamic acid administration. Therefore, we suggest that tranexamic acid should be intravenously administered pre-operatively and the posterior soft tissue should be repaired to decrease total hip arthroplasty-related complications. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  8. Hip contact forces in asymptomatic total hip replacement patients differ from normal healthy individuals: Implications for preclinical testing.

    PubMed

    Li, Junyan; Redmond, Anthony C; Jin, Zhongmin; Fisher, John; Stone, Martin H; Stewart, Todd D

    2014-08-01

    Preclinical durability testing of hip replacement implants is standardised by ISO-14242-1 (2002) which is based on historical inverse dynamics analysis using data obtained from a small sample of normal healthy individuals. It has not been established whether loading cycles derived from normal healthy individuals are representative of loading cycles occurring in patients following total hip replacement. Hip joint kinematics and hip contact forces derived from multibody modelling of forces during normal walking were obtained for 15 asymptomatic total hip replacement patients and compared to 38 normal healthy individuals and to the ISO standard for pre-clinical testing. Hip kinematics in the total hip replacement patients were comparable to the ISO data and the hip contact force in the normal healthy group was also comparable to the ISO cycles. Hip contact forces derived from the asymptomatic total hip replacement patients were comparable for the first part of the stance period but exhibited 30% lower peak loads at toe-off. Although the ISO standard provides a representative kinematic cycle, the findings call into question whether the hip joint contact forces in the ISO standard are representative of those occurring in the joint following total hip replacement. Copyright © 2014. Published by Elsevier Ltd.

  9. Unilateral total hip replacement patients with symptomatic leg length inequality have abnormal hip biomechanics during walking.

    PubMed

    Li, Junyan; McWilliams, Anthony B; Jin, Zhongmin; Fisher, John; Stone, Martin H; Redmond, Anthony C; Stewart, Todd D

    2015-06-01

    Symptomatic leg length inequality accounts for 8.7% of total hip replacement related claims made against the UK National Health Service Litigation authority. It has not been established whether symptomatic leg length inequality patients following total hip replacement have abnormal hip kinetics during gait. Hip kinetics in 15 unilateral total hip replacement patients with symptomatic leg length inequality during gait was determined through multibody dynamics and compared to 15 native hip healthy controls and 15 'successful' asymptomatic unilateral total hip replacement patients. More significant differences from normal were found in symptomatic leg length inequality patients than in asymptomatic total hip replacement patients. The leg length inequality patients had altered functions defined by lower gait velocity, reduced stride length, reduced ground reaction force, decreased hip range of motion, reduced hip moment and less dynamic hip force with a 24% lower heel-strike peak, 66% higher mid-stance trough and 37% lower toe-off peak. Greater asymmetry in hip contact force was also observed in leg length inequality patients. These gait adaptions may affect the function of the implant and other healthy joints in symptomatic leg length inequality patients. This study provides important information for the musculoskeletal function and rehabilitation of symptomatic leg length inequality patients. Copyright © 2015. Published by Elsevier Ltd.

  10. The tribology of metal-on-metal total hip replacements.

    PubMed

    Scholes, S C; Unsworth, A

    2006-02-01

    Total hip surgery is an effective way of alleviating the pain and discomfort caused by diseased or damaged joints. However, in the majority of cases, these joints have a finite life. The main reason for failure is osteolysis (bone resorption). It is well documented that an important cause of osteolysis, and therefore the subsequent loosening and failure of conventional metal- or ceramic-on-ultra-high molecular weight polyethylene joints, is the body's immunological response to the polyethylene wear particles. To avoid this, interest has been renewed in metal-on-metal joints. The intention of this paper is to review the studies that have taken place within different laboratories to determine the tribological performance of new-generation metal-on-metal total hip replacements. These types of joint offer a potential solution to enhance the longevity of prosthetic hip systems; however, problems may arise owing to the effects of metal ion release, which are, as yet, not fully understood.

  11. [Progress assessment of rehabilitation in patients after hip replacement. Preliminary report].

    PubMed

    Labecka, Monika; Pingot, Mariusz; Pingot, Julia; Woldańiska-Okońska, Marta

    2014-01-01

    Coxarthrosis is one of the most common diseases of the motor system. We distinguish primary and secondary coxarthrosis. The premises for total hip replacement include pain, damage to the surface of the acetabulum and the head of the hip, relative shortening of the limb, gluteal, femur and crus muscle atrophy and gait dysfunctions. The aim of this paper is to present the influence of rehabilitation on the improvement of physical ability, especially in respect to quality of gait and antianalgesic efficacy of the physical therapy in patients after total hip replacement. The study was carried out in 37 patients aged 35-72 (mean of age--53.78 +/- 9.92). The group consisted'of 21 women and 16 men. After the total hip replacement, all the patients underwent physical therapy which involved application of laser radiation on the postoperative scar, whirpool and classic massage of the operated limb, exercises in non-weight bearing and weight-bearing exercises and gait reeducation. Modified Laitinen Pain Indicator Questionnaire, Visual Analogue Scale-VAS and the standardized mobility test--Timed-Up-And-Go test were used in the study. The statistical analysis was carried out with the use of the STATYSTIKA 5 PL computer program. The results reached point to the analgesic efficacy of the physical therapy and a better gait quality. Multifactor physical therapy after total hip replacement shows analgesic action. Appropriate selection of exercises and physical treatment have positive influence on gait reeducation in patients after total hip replacement. The Timed Up and Go test may be used in functional assessment of gait in patients with musculoskeletal disorders.

  12. A new system of computer-assisted navigation leading to reduction in operating time in uncemented total hip replacement in a matched population.

    PubMed

    Chaudhry, Fouad A; Ismail, Sanaa Z; Davis, Edward T

    2018-05-01

    Computer-assisted navigation techniques are used to optimise component placement and alignment in total hip replacement. It has developed in the last 10 years but despite its advantages only 0.3% of all total hip replacements in England and Wales are done using computer navigation. One of the reasons for this is that computer-assisted technology increases operative time. A new method of pelvic registration has been developed without the need to register the anterior pelvic plane (BrainLab hip 6.0) which has shown to improve the accuracy of THR. The purpose of this study was to find out if the new method reduces the operating time. This was a retrospective analysis of comparing operating time in computer navigated primary uncemented total hip replacement using two methods of registration. Group 1 included 128 cases that were performed using BrainLab versions 2.1-5.1. This version relied on the acquisition of the anterior pelvic plane for registration. Group 2 included 128 cases that were performed using the newest navigation software, BrainLab hip 6.0 (registration possible with the patient in the lateral decubitus position). The operating time was 65.79 (40-98) minutes using the old method of registration and was 50.87 (33-74) minutes using the new method of registration. This difference was statistically significant. The body mass index (BMI) was comparable in both groups. The study supports the use of new method of registration in improving the operating time in computer navigated primary uncemented total hip replacements.

  13. Actis Total Hip System 2 Year Follow-up

    ClinicalTrials.gov

    2017-08-14

    Osteoarthritis; Traumatic Arthritis; Rheumatoid Arthritis; Congenital Hip Dysplasia; Avascular Necrosis of the Femoral Head; Acute Traumatic Fracture of the Femoral Head or Neck; Certain Cases of Ankylosis; Non-union of Femoral Neck Fractures; Certain High Sub-Capital & Femoral Neck Fractures in Elderly

  14. [Ceramic-ceramic articulation in uncemented total hip arthroplasty].

    PubMed

    Synder, Marek; Drobniewski, Marek; Kozłowski, Piotr; Grzegorzewski, Andrzej

    2005-01-01

    The main problem in total hip arthroplasty (THA) surgery is aseptic loosening of prosthesis components. In most cases the phagocytes reaction against the wear particle during the hip movement is responsible for aseptic prosthesis loosening. To prevent this reaction different hip articulation are invented to reduce this reaction. One of these solutions is ceramic-ceramic hip prosthesis articulation. The aim of this study was to evaluate the long-term results in patients who were treated because of coxarthrosis by means of ceramic-ceramic hip prosthesis. We analyzed 258 primary THA (222 patients, 116 women and 106 men) who were treated because of advanced coxarthrosis by Mittelmeier type hip endoprosthesis (ceramic-ceramic articulation). The mean age of patients at the surgery was 45.6 years and a mean follow-up 10.2 years. In most of our cases the idiopathic, traumatic and dysplastic coxarthrosis was noted. For clinical evaluation the classification system proposed by Merle d'Aubigne and Postel with Charnley modification was used. For radiological evaluation of the steam implantation the classification system proposed by De Lee and Charnley was used and for the cup implantation the system by Gruen and Moreland. In 87 patients (33.7%) the final results was graded as very good, in 96 (37.2%) as good, in 47 (18.2%) as satisfactory and in 28 patients (10.9%) the final results was poor. In analyzed group in 13 patients (5.0%) the revision surgery was necessary. The long-term results of THA with the use of Mittelmeier type of hip prosthesis presented a very low percentage of aseptic loosening. This type of prosthesis gives very high patients satisfaction.

  15. Thirteen-year outcomes in the Anatomique Benoist Girard II hip prosthesis.

    PubMed

    Catanach, Michael J M; Sorial, Rami M; Eslick, Guy D

    2015-04-01

    The Stryker Anatomique Benoist Girard (ABG) hip implant system was a commonly used cementless prosthesis in the early 2000s, which fell from favour after several studies emerged implicating the prosthesis in high rates of revision. This retrospective, single-surgeon clinical study examines the fracture rate, revision rate and reasons for revision in 500 consecutive ABG II primary total conventional hip replacements. Follow-up was conducted by audit of patient notes, patient mailout survey, patient phone contact and audit of the Australian National Joint Replacement Registry (NJRR) database to find instances of fracture and revision. End points were periprosthetic fracture and revision for any reason. Follow-up was 1.2-13.8 years with a mean of 6.58 years. Of the 500 hips, 17 (3.4%) had undergone a revision. Of these, 13 were due to periprosthetic fracture. Four further fractures occurred that were not revised. Eight of these periprosthetic fractures occurred within 1 year post-operatively. There were four revisions for recurrent dislocations. Kaplan-Meier survival curve demonstrates a 93.7% survivorship at 6.58 years for revision for any reason. Multivariate analysis showed the only statistically significant factor for increased risk of revision was smaller stem size. Our results were consistent with the literature in that the ABG II system has good medium-term results but is prone to periprosthetic fractures, especially in the early post-operative period. When used as a primary total hip arthroplasty, the ABG II system has an 8-year revision rate of 5.6% compared with the 4.9% of all primary total hip arthroplasties. © 2014 Royal Australasian College of Surgeons.

  16. Physical activity of elderly patients after total hip arthroplasty.

    PubMed

    Cukras, Zbigniew; Praczko, Katarzyna; Kostka, Tomasz; Jegier, Anna

    2007-01-01

    Total hip arthroplasty (THA) is the most common method of treatment of severe hip osteoarthritis. There is little data concerning the physical activity of total hip arthroplasty patients in Poland and investigations to explore this area are useful. The aim of the study was to describe the post-operative physical activity of total hip arthroplasty patients. A total of 146 adult people were examined, among which 28 men and 41 women had undergone total hip arthroplasty due to primary osteoarthritis of the hip, while another 32 men and 41 women matched for age who had not undergone hip surgery for osteoarthritis served as controls. The physical activity of study participants was assessed with the 7-Day Physical Activity Recall Questionnaire. All participants were also asked about the type and amount of physical activity they engaged in to maintain good health. Physical activity measured as the total amount of calories expended through physical activity per week was similar in the post-THA patients compared to the controls. The only differences were a smaller amount of calories expended during low-intensity physical activity by men after total hip arthroplasty compared to men who had not undergone surgery for osteoarthritis and a smaller amount of calories expended through high-intensity physical activity by women after total hip arthroplasty compared to female controls. The kinds of recreational physical activity most commonly practised by patients a mean of two years after total hip arthroplasty were marching, bicycling and general body conditioning exercises (usually the continuation of exercises recommended during post-operative rehabilitation). The percentage of post-THA patients undertaking physical activity for the prevention of non-communicable diseases was low. Physical activity should be more effectively encouraged in patients after total hip arthroplasty.

  17. [A project to provide instruction in the nursing of elderly patients with total hip replacement (T.H.R.)].

    PubMed

    Ting, Chao-Fong; Chou, Hsiu-Ling; Chen, Ming-Mie

    2006-02-01

    This project was aimed at improving the nursing of patients who have undergone total hip replacements. Investigation showed the following problems with existing nursing instruction in this area: lack of standard instruction, outdated educational materials, a 33.75% rate of completion of instruction lack of familiarity with instruction materials, and an average satisfaction score of 2.56 among nurses who have undergone instruction; The reading for patient's satisfaction with the guidance of nurses was 2.04. After site investigation, status analysis and reference check, we proposed the following program. (1) Establish standards and monitor tools for instruction for nursing total hip replacement patients, including "Caring standard", "Guidance for nursing instruction", "Nursing instruction sheet", "Notes at nursing instruction", "Satisfaction scoring system for nursing instruction"; (2) Carry out a training course to enhance nursing staff's knowledge about caring for patients with total hip replacement. After program had been implemented, a completion rate of 88.56% was achieved, and the satisfaction scores among nursing staff and patients were 4.3 and 4.36 respectively. This result shows that when we undertake reform at various different levels--including systemic structure, processing and monitoring--this can radically improve the quality of nursing instruction.

  18. Clinico-radiological diagnosis and grading of rapidly progressive osteoarthritis of the hip.

    PubMed

    Zazgyva, Ancuţa; Gurzu, Simona; Gergely, István; Jung, Ioan; Roman, Ciprian O; Pop, Tudor S

    2017-03-01

    Due to the current lack of standard definitions for rapidly progressive osteoarthritis of the hip (RPOH) in the literature, this observational study aimed to describe new diagnostic criteria and a grading system for the disease.From a consecutive series of patients undergoing total hip replacement, 2 groups were selected: 1 with RPOH and 1 with primary hip osteoarthritis (POH), and their clinical, paraclinical, and demographic data were compared. The newly proposed clinico-radiological diagnostic criteria are based on characteristics of pain, joint mobility, and radiological assessment. The radiological grading system's inter- and intraobserver reliability was assessed through serial evaluations by 2 blinded reviewers.From the total 863 cases, 82 cases (9.5%) of RPOH were identified and compared with 107 cases of POH. Mean age and disease bilaterality were similar, with a predominance of female patients in the RPOH group (P = 0.03). There were significant differences between the 2 groups in disease onset and aggravation, and intraoperative blood loss. The grading system showed significant inter- and intraobserver agreement (weighted kappa 0.93, and 0.89).Our study presents distinctive, easily recognizable clinico-radiological characteristics of RPOH and confirmed the inter- and intraobserver reliability of the newly proposed grading system.

  19. An in vitro simulation method for the tribological assessment of complete natural hip joints

    PubMed Central

    Fisher, John; Williams, Sophie

    2017-01-01

    The use of hip joint simulators to evaluate the tribological performance of total hip replacements is widely reported in the literature, however, in vitro simulation studies investigating the tribology of the natural hip joint are limited with heterogeneous methodologies reported. An in vitro simulation system for the complete natural hip joint, enabling the acetabulum and femoral head to be positioned with different orientations whilst maintaining the correct joint centre of rotation, was successfully developed for this study. The efficacy of the simulation system was assessed by testing complete, matched natural porcine hip joints and porcine hip hemiarthroplasty joints in a pendulum friction simulator. The results showed evidence of biphasic lubrication, with a non-linear increase in friction being observed in both groups. Lower overall mean friction factor values in the complete natural joint group that increased at a lower rate over time, suggest that the exudation of fluid and transition to solid phase lubrication occurred more slowly in the complete natural hip joint compared to the hip hemiarthroplasty joint. It is envisaged that this methodology will be used to investigate morphological risk factors for developing hip osteoarthritis, as well as the effectiveness of early interventional treatments for degenerative hip disease. PMID:28886084

  20. Long-term results with the Atlas IIIp elastic cementless acetabular component in total hip replacement.

    PubMed

    Lee, Paul Yuh Feng; Rachala, Madhu; Teoh, Kar Ho; Woodnutt, David John

    2016-09-01

    Modular cementless elastic acetabular systems have advantages over cemented and hard shell cementless acetabular systems. There are few reports on the medium-term and long-term follow up of this particular type of implant. This study describes our experience with the Atlas IIIp modular acetabular system, which is a thin shell cementless elastic acetabular implant for total hip replacement commercialized under this name in many countries. We prospectively followed 244 patients treated with Atlas IIIp acetabular system between 2001 and 2004. Minimum ten year follow up was available for 148 hips (139 patients) from the original cohort of 263 hips (244 patients). One hundred five patients had died from unrelated causes and were excluded from the results. Post-operative and follow up radiographs of patients were assessed; and Harris hip scores were used as clinical outcome. Revision for any reason was defined as the end point for survivorship analysis. The mean pre-operative Harris hip score was 48 (S.D. 16) and the average post-operative score was 82 (S.D. 12). The mean follow up in our series was 11.5 years, ranging from ten to 13.5 years. Thirteen hips required further surgery in our cohort; of which ten cases required cup revision. The 13-years cumulative implant survival was 91.2 % and the risk of implant revision was 8.8 % at 13 years in 148 hips (139 patients). Kaplan-Meier analysis showed the implant survival rate of 95.2 % at ten years for revision for any reason and 99.4 % for aseptic loosening. Our clinical experience with this acetabular cup suggests good long-term survival rates that are similar to other cups on the market. The clinical experience in this study shows long-term survival rates that are consistent, acceptable and good results achieved with a low revision rate. Therapeutic III; therapeutic study.

  1. The High Value Healthcare Collaborative: Observational Analyses of Care Episodes for Hip and Knee Arthroplasty Surgery.

    PubMed

    Weeks, William B; Schoellkopf, William J; Sorensen, Lyle S; Masica, Andrew L; Nesse, Robert E; Weinstein, James N

    2017-03-01

    Broader use of value-based reimbursement models will require providers to transparently demonstrate health care value. We sought to determine and report cost and quality data for episodes of hip and knee arthroplasty surgery among 13 members of the High Value Healthcare Collaborative (HVHC), a consortium of health care systems interested in improving health care value. We conducted a retrospective, cross-sectional observational cohort study of 30-day episodes of care for hip and knee arthroplasty in fee-for-service Medicare beneficiaries aged 65 or older who had hip or knee osteoarthritis and used 1 of 13 HVHC member systems for uncomplicated primary hip arthroplasty (N = 8853) or knee arthroplasty (N = 16,434), respectively, in 2012 or 2013. At the system level, we calculated: per-capita utilization rates; postoperative complication rates; standardized total, acute, and postacute care Medicare expenditures for 30-day episodes of care; and the modeled impact of reducing episode expenditures or per-capita utilization rates. Adjusted per-capita utilization rates varied across HVHC systems and postacute care reimbursements varied more than 3-fold for both types of arthroplasty in both years. Regression analysis confirmed that total episode and postacute care reimbursements significantly differed across HVHC members after considering patient demographic differences. Potential Medicare cost savings were greatest for knee arthroplasty surgery and when lower total reimbursement targets were achieved. The substantial variation that we found offers opportunities for learning and collaboration to collectively improve outcomes, reduce costs, and enhance value. Ceteris paribus, reducing per-episode reimbursements would achieve greater Medicare cost savings than reducing per-capita rates. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Muscle strength and areal bone mineral density at the hip in women: a cross-sectional study.

    PubMed

    Pasco, Julie A; Holloway, Kara L; Brennan-Olsen, Sharon L; Moloney, David J; Kotowicz, Mark A

    2015-05-24

    Muscle strengthening exercises are promoted for building and maintaining a healthy skeleton. We aimed to investigate the relationship between muscle strength and areal bone mineral density (BMD) at the hip in women aged 26-97 years. This cross-sectional study utilises data from 863 women assessed for the Geelong Osteoporosis Study. Measures of hip flexor and abductor strength were made using a hand-held dynamometer (Nicholas Manual Muscle Tester). The maximal measure from three trials on each leg was used for analyses. BMD was measured at the hip using dual energy x-ray absorptiometry (DXA; Lunar DPX-L). Total lean mass, body fat mass and appendicular lean mass were determined from whole body DXA scans. Linear regression techniques were used with muscle strength as the independent variable and BMD as the dependent variable. Models were adjusted for age and indices of body composition. Measures of age-adjusted hip flexor strength and hip abductor strength were positively associated with total hip BMD. For each standard deviation (SD) increase in hip flexor strength, the increase in mean total hip BMD (SD) was 10.4 % (p = 0.009). A similar pattern was observed for hip abductor strength, with an increase in mean total hip BMD of 22.8 % (p = 0.025). All associations between hip muscle strength and total hip BMD were independent of height, but were nullified after adjusting for appendicular lean mass or total lean mass. There was a positive association observed between muscle strength and BMD at the hip. However, this association was explained by measures of lean mass.

  3. Tendon Disorders After Total Hip Arthroplasty: Evaluation and Management.

    PubMed

    Capogna, Brian M; Shenoy, Kartik; Youm, Thomas; Stuchin, Steven A

    2017-10-01

    Most patients who undergo total hip arthroplasty are very satisfied with their outcomes. However, there is a small subset of patients who have persistent pain after surgery. The etiology of pain after total hip arthroplasty varies widely; however, tendon disorders are a major cause of debilitating pain that often go unrecognized. We performed a literature review to identify the most common tendon pathologies after total hip arthroplasty which include iliopsoas tendinitis, greater trochanteric pain syndrome, snapping hip syndrome, and abductor tendinopathy. We present a simplified approach highlighting the presentation and management of patients with suspected tendinopathies after total hip arthroplasty. These tendinopathies are treatable, and management begins with nonoperative modalities; however, in cases not responsive to conservative management, operative intervention may be necessary. Tendinopathies after total hip arthroplasty sometimes go unrecognized but when treated can result in higher surgeon and patient satisfaction. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Genetic evaluation of the total hip score of four populous breeds of dog, as recorded by the New Zealand Veterinary Association Hip Dysplasia Scheme (1991-2011).

    PubMed

    Soo, M; Sneddon, N W; Lopez-Villalobos, N; Worth, A J

    2015-03-01

    To use estimated breeding value (EBV) analysis to investigate the genetic trend of the total hip score (to assess canine hip dysplasia) in four populous breeds of dogs using the records from the New Zealand Veterinary Association (NZVA) Canine Hip Dysplasia Scheme database (1991 to 2011). Estimates of heritability and EBV for the NZVA total hip score of individual dogs from the German Shepherd, Labrador Retriever, Golden Retriever and Rottweiler breeds were obtained using restricted maximum likelihood procedures with a within-breed linear animal model. The model included the fixed effects of gender, birth year, birth season, age at scoring and the random effect of animal. The pedigree file included animals recorded between 1990 and 2011. A total of 2,983 NZVA hip score records, from a pedigree of 3,172 animals, were available for genetic evaluation. Genetic trends of the NZVA total hip score were calculated as the regression coefficient of the EBV (weighted by reliabilities) on year of birth. The estimates of heritability for hip score were 0.32 (SE 0.08) in German Shepherd, 0.37 (SE 0.08) in Labrador Retriever, 0.29 (SE 0.08) in Golden Retriever and 0.52 (SE 0.18) in Rottweiler breeds. Genetic trend analysis revealed that only the German Shepherd breed exhibited a genetic trend towards better hip conformation over time, with a decline of 0.13 (SE 0.04) NZVA total hip score units per year (p<0.001). The genetic trends of total hip score for the remaining three breeds were not significantly different from zero (p>0.1). Despite moderate heritability of the NZVA total hip score, there has not been substantial improvement of this trait for the four breeds analysed in the study period. Greater improvement in reducing the prevalence of canine hip dysplasia may be possible if screening were to be compulsory as a requirement for registration of pedigree breeding stock, greater selection pressure were to be applied and selection of breeding stock made on the basis on an individual's EBV rather than the NZVA total hip score alone.

  5. Interactions between serum leptin, the insulin-like growth factor-I system, and sex, age, anthropometric and body composition variables in a healthy population randomly selected.

    PubMed

    Gómez, José Manuel; Maravall, Francisco Javier; Gómez, Núria; Navarro, Miguel Angel; Casamitjana, Roser; Soler, Juan

    2003-02-01

    Leptin secretion is influenced by many factors and the GH/IGF axis plays an important role in the regulation of body composition, but the physiological interactions between leptin and the IGF-I system remain unknown. In this study we investigated the relationship between leptin, the IGF-I system, and sex, age, anthropometric and body composition variables in a group of healthy adults randomly selected. A cross-sectional study. The study included 268 subjects, representative of the whole population of the city of L'Hospitalet de Llobregat in sex and age distribution: 134 men aged 41.4 years, range 15-70 years; and 134 women, aged 40.7 years, range 15-70 years. Body mass index (BMI) was calculated, and body composition was determined by using a bioelectrical impedance analyser. Serum leptin concentrations were determined by using a radioimmunoassay (RIA). Serum total IGF-I concentrations, after acid-ethanol extraction, were also measured by RIA. Serum free IGF-I concentrations were determined by an enzymoimmunometric assay. Serum IGFBP3 concentrations were determined by RIA. Plasma basal TSH concentrations were determined by a specific electrochemiluminescence assay. In men the BMI was similar in all decades and waist/hip ratio increased in the last three decades. Fat-free mass decreased by decade. We observed an increase in leptin in the fourth decade with a decrease in IGF-I, free IGF-I and IGFBP3 throughout the decades. Basal TSH showed an increase in the last two decades. In women, BMI, waist/hip ratio and fat mass increased significantly in the last decades. Leptin concentrations increased in the last decades and total IGF-I, free IGF-I and IGFBP3 decreased by decade without changes in basal TSH concentration. In men, there was a positive correlation between leptin and BMI, waist/hip ratio, total body water, fat-free mass and fat mass, and these anthropometric and body composition variables showed a negative correlation with free IGF-I and IGFBP3, without any correlation with total IGF-I. In women, there was a positive correlation between leptin and BMI, waist/hip ratio, total body water, fat-free mass, and fat mass, which showed a negative correlation with total IGF-I and IGFBP3, without any correlation with free IGF-I. In men, total IGF-I was negatively correlated with waist/hip ratio without any correlation with the other variables and free IGF-I was negatively correlated with BMI and waist/hip ratio, and IGFBP3 did not show any correlation. In women, total IGF-I, free IGF-I and IGFBP3 were negatively correlated with BMI, waist/hip ratio and fat mass. The multiple linear regression analysis produced a model that explained 60.5% of leptin variability in men and 40% in women. Notably, only age, BMI, fat mass and waist/hip ratio brought an independent significant contribution to leptin variability. The final model also explained 28.2% and 60.4% of total IGF-I variability and 17.2% and 27.4% of free IGF-I variability in men and women, respectively. Age and leptin contributed to free IGF-I variability in men, and age and fat mass were significantly and independently associated with total IGF-I in women. In this well-characterized population of controls randomly selected without chronic disease or drug administration and with biochemically confirmed euthyroidism, we found that both men and women had a significant correlation between leptin levels and the IGF-I system, and anthropometric and body composition variables, but that leptin did not regulate the IGF-I system, and that the IGF-I system did not regulate leptin synthesis and secretion.

  6. Increasing hip fracture rates among older adults in Ecuador: analysis of the National Hospital Discharge System, 1999-2016.

    PubMed

    Orces, Carlos H; Gavilanez, Enrique Lopez

    2017-12-07

    The Ecuadorian hospital discharge system examined trends in hip fracture hospitalization rates among older adults. A significant upward trend in hip fracture rates occurred in both genders over the study period. Previous research has reported increasing hip fracture rates in Ecuador. Thus, this study aimed to extend previous findings by examining the nationwide incidence of hip fractures among adults aged 65 years and older between 1999 and 2016. A secondary objective was to compare hip fracture trends among older Ecuadorians with their counterparts in the United States (U.S.). The National Hospital Discharge System and the Healthcare Cost and Utilization Project net were assessed to identify older adults hospitalized with a principal diagnosis of hip fractures in Ecuador and the U.S., respectively. The Joinpoint regression analysis software was used to examine the average annual percent change in hip fracture rates. A total of 20,091 adults with a mean age of 82.3 (SD 8.1) years were hospitalized with a principal diagnosis of hip fractures during the study period. After an adjustment for age, hip fracture rates increased annually on average by 4.6% (95% CI 3.8%, 5.4%) from 96.4/100,000 in 1999 to 173.1/100,000 persons in 2016. Between 1999 and 2014, hip fracture age-adjusted rates decreased on average by - 2.5% (95% CI - 2.7%, - 2.3%) among older adults in the U.S. while hip fracture rates steadily increased by 4.6% (95% CI, 3.6%, 5.7%) per year in their Ecuadorian counterparts. Hip fracture rates markedly increased among older adults in Ecuador. The present findings should alert public health authorities to implement policies of osteoporosis awareness and prevention in Ecuador.

  7. Survey of patient-oriented total hip replacement information on the World Wide Web.

    PubMed

    Mabrey, J D

    2000-12-01

    The author conducted an informal survey of materials relating to diseases of the hip and total hip replacement as they appeared on the World Wide Web. The results varied depending on the key words used: hip and replacement yielded 1,818 matches; total hip replacement yielded 1,740 matches; hip replacement yielded 4,565 sites; and hip surgery yielded 1,073 sites. The number of sites for total hip replacement was observed to increase with time, having found an additional 30 sites from an identical search performed only 6 weeks earlier. The nature and quality of these sites varied from well-organized and informative, to personal testaments, to obvious commercial endeavors. Overall, this survey found an abundance of material regarding the hip and hip replacements on the World Wide Web, but orthopaedic societies need to take a more active role in constructing, maintaining, and monitoring these sites to best serve the needs of their patients and their members.

  8. Prevalence of Total Hip and Knee Replacement in the United States.

    PubMed

    Maradit Kremers, Hilal; Larson, Dirk R; Crowson, Cynthia S; Kremers, Walter K; Washington, Raynard E; Steiner, Claudia A; Jiranek, William A; Berry, Daniel J

    2015-09-02

    Descriptive epidemiology of total joint replacement procedures is limited to annual procedure volumes (incidence). The prevalence of the growing number of individuals living with a total hip or total knee replacement is currently unknown. Our objective was to estimate the prevalence of total hip and total knee replacement in the United States. Prevalence was estimated using the counting method by combining historical incidence data from the National Hospital Discharge Survey and the Healthcare Cost and Utilization Project (HCUP) State Inpatient Databases from 1969 to 2010 with general population census and mortality counts. We accounted for relative differences in mortality rates between those who have had total hip or knee replacement and the general population. The 2010 prevalence of total hip and total knee replacement in the total U.S. population was 0.83% and 1.52%, respectively. Prevalence was higher among women than among men and increased with age, reaching 5.26% for total hip replacement and 10.38% for total knee replacement at eighty years. These estimates corresponded to 2.5 million individuals (1.4 million women and 1.1 million men) with total hip replacement and 4.7 million individuals (3.0 million women and 1.7 million men) with total knee replacement in 2010. Secular trends indicated a substantial rise in prevalence over time and a shift to younger ages. Around 7 million Americans are living with a hip or knee replacement, and consequently, in most cases, are mobile, despite advanced arthritis. These numbers underscore the substantial public health impact of total hip and knee arthroplasties. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  9. [Optimizing primary total hip replacement--a technique to effect saving of manpower].

    PubMed

    Huber, J F; Rink, M; Broger, I; Zumstein, M; Ruflin, G B

    2003-01-01

    Development of a standardized surgical technique for total hip replacement thereby saving manpower (one assistant) by using a retractor system. Total hip replacement is performed with the patient in a true lateral position on a tunnel cushion. By means of a direct lateral approach the pelvitrochanteric muscles are partially detached using an omega-shaped cut. The Bookwalter retractor is fixed dorsally on the operating table. The ring is centered keeping the greater trochanter in the middle. The Hohmann retractors are fixed to the ring to sufficiently expose the acetabulum. To insert the femoral stem the ring needs to be opened dorsally and the patient's leg is bent 90 degrees in the hip and the knee over the tunnel cushion. The muscles inserting at the greater trochanter are retracted by a separate Hohmann retractor with weight. In a case control study with matched pairs the patients treated with this technique were compared with those treated in supine position with the transgluteal approach. The number of assistants required and the operating time were assessed. All the hip replacements with the patient in side position were performed with one assistant, in supine position with two assistants. The operating time did not differ significantly (supine position 110 min/side position 112 min). The complication rate in both groups was comparable (one secondary wound healing, one transient ischalgia). The process of total hip replacement can be optimized. The described technique allows to spare one surgical assistant without prolonging the operating time.

  10. Hip rotation range of motion in sitting and prone positions in healthy Japanese adults

    PubMed Central

    Han, Heonsoo; Kubo, Akira; Kurosawa, Kazuo; Maruichi, Shizuka; Maruyama, Hitoshi

    2015-01-01

    [Purpose] The aim of this study was to elucidate the difference in hip external and internal rotation ranges of motion (ROM) between the prone and sitting positions. [Subjects] The subjects included 151 students. [Methods] Hip rotational ROM was measured with the subjects in the prone and sitting positions. Two-way repeated measures analysis of variance (ANOVA) was used to analyze ipsilateral hip rotation ROM in the prone and sitting positions in males and females. The total ipsilateral hip rotation ROM was calculated by adding the measured values for external and internal rotations. [Results] Ipsilateral hip rotation ROM revealed significant differences between two positions for both left and right internal and external rotations. Hip rotation ROM was significantly higher in the prone position than in the sitting position. Hip rotation ROM significantly differed between the men and women. Hip external rotation ROM was significantly higher in both positions in men; conversely, hip internal rotation ROM was significantly higher in both positions in women. [Conclusion] Hip rotation ROM significantly differed between the sexes and between the sitting and prone positions. Total ipsilateral hip rotation ROM, total angle of external rotation, and total angle of internal rotation of the left and right hips greatly varied, suggesting that hip joint rotational ROM is widely distributed. PMID:25729186

  11. Association Between Pseudotumor Formation and Patient Factors in Metal-on-Metal Total Hip Arthroplasty Population.

    PubMed

    Kleeman, Lindsay T; Goltz, Daniel; Seyler, Thorsten M; Mammarappallil, Joseph G; Attarian, David E; Wellman, Samuel S; Bolognesi, Michael P

    2018-07-01

    Pseudotumor formation from metal-on-metal (MoM) hip implants is associated with implant revision. The relationship between pseudotumor type and patient outcomes is unknown. We retrospectively reviewed patients with a MoM total hip arthroplasty and metal artifact reduction sequence magnetic resonance imaging. Pseudotumors were graded using a validated classification system by a fellowship-trained radiologist. Patient demographics, metal ion levels, and implant survival were analyzed. Pseudotumors were present in 49 hips (53%). Thirty-two (65%) pseudotumors were cystic thin walled, 8 (16%) were cystic thick walled, and 9 (18%) were solid masses. Patients with pseudotumors had high offset stems (P = .030) but not higher metal ion levels. Patients with thick-walled cystic or solid masses were more likely to be symptomatic (P = .025) and were at increased risk for revision (P = .004) compared to patients with cystic lesions. Pseudotumor formation is present in 53% of patients with a MoM total hip arthroplasty, of which 40% were asymptomatic. Patients with thick-walled cystic and solid lesions were more likely to be symptomatic and undergo revision. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Single-dose radiation therapy for prevention of heterotopic ossification after total hip arthroplasty

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Healy, W.L.; Lo, T.C.; Covall, D.J.

    1990-12-01

    Single-dose radiation therapy was prospectively evaluated for its efficacy in prevention of heterotopic ossification in patients at high risk after total hip arthroplasty. Thirty-one patients (34 hips) were treated between 1981 and 1988. Risk factors for inclusion in the protocol included prior evidence of heterotopic ossification, ankylosing spondylitis, and diffuse idiopathic skeletal hyperostosis. Patients with hypertrophic osteoarthritis or traumatic arthritis with osteophytes were not included. Operations on 34 hips included 19 primary total and 11 revision total hip arthroplasties and 4 excisions of heterotopic ossification. All patients received radiotherapy to the hip after operation with a single dose of 700more » centigray. Radiotherapy is recommended on the first postoperative day. After this single-dose radiation treatment, no patient had clinically significant heterotopic ossification. Recurrent disease developed in two hips (6%), as seen on radiography (grades 2 and 3). This series documents a 100% clinical success rate and a 94% radiographic success rate in preventing heterotopic ossification in patients at high risk after total hip arthroplasty. Single-dose radiotherapy is as effective as other radiation protocols in preventing heterotopic ossification after total hip arthroplasty. It is less expensive and easier to administer than multidose radiotherapy.« less

  13. Verification of the Robin and Graham classification system of hip disease in cerebral palsy using three-dimensional computed tomography.

    PubMed

    Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Akiyama, Keisuke; Yoshikawa, Hideki; Sugamoto, Kazuomi

    2011-12-01

    We evaluated the validity of the Robin and Graham classification system of hip disease in cerebral palsy (CP) using three-dimensional computed tomography in young people with CP. A total of 91 hips in 91 consecutive children with bilateral spastic CP (57 males, 34 females; nine classified at Gross Motor Function Classification System level II, 42 at level III, 32 at level IV, and eight at level V; mean age 5 y 2 mo, SD 11 mo; range 2-6 y) were investigated retrospectively using anteroposterior plain radiographs and three-dimensional computed tomography (3D-CT) of the hip. The migration percentage was calculated on plain radiographs and all participants were classified into four groups according to migration percentage: grade II, migration percentage ≥ 10% but ≤ 15%, (four hips), grade III, migration percentage >15% but ≤ 30%, (20 hips); grade IV, migration percentage >30% but <100%, (63 hips); and grade V, migration percentage ≥ 100%, (four hips). The lateral opening angle and the sagittal inclination angle of the acetabulum, the neck-shaft angle, and the femoral anteversion of the femur were measured on 3D-CT. The three-dimensional quantitative evaluation indicated that there were significant differences in the lateral opening angle and the neck-shaft angle between the four groups (Kruskal-Wallis test, p ≤ 0.001). This three-dimensional evaluation supports the validation of the Robin and Graham classification system for hip disease in 2- to 7-year-olds with CP. © The Authors. Developmental Medicine & Child Neurology © 2011 Mac Keith Press.

  14. Unipedal standing exercise and hip bone mineral density in postmenopausal women: a randomized controlled trial.

    PubMed

    Sakai, Akinori; Oshige, Toshihisa; Zenke, Yukichi; Yamanaka, Yoshiaki; Nagaishi, Hitoshi; Nakamura, Toshitaka

    2010-01-01

    The aim of this study was to test the effect of unipedal standing exercise on bone mineral density (BMD) of the hip in postmenopausal women. Japanese postmenopausal women (n = 94) were assigned at random to an exercise or control group (no exercise). The 6-month exercise program consisted of standing on a single foot for 1 min per leg 3 times per day. BMD of the hip was measured by dual-energy X-ray absorptiometry. There was no significant difference in age and baseline hip BMD between the exercise group (n = 49) and control group (n = 45). Exercise did not improve hip BMD compared with the control group. Stepwise regression analysis identified old age as a significant determinant (p = 0.034) of increased hip total BMD at 6 months after exercise. In 31 participants aged >/=70 years, the exercise group (n = 20) showed significant increase in the values of hip BMD at the areas of total (p = 0.008), intertrochanteric (p = 0.023), and Ward's triangle (p = 0.032). The same parameters were decreased in the control group (n = 11). The percent changes in hip BMD of the exercise group were not significantly different from those of the control group either in the participants with low baseline hip total BMD (<80% of the young adult mean) or high baseline hip total BMD (> or =80% of the young adult mean). In conclusion, unipedal standing exercise for 6 months did not improve hip BMD in Japanese postmenopausal women. Effect of exercise on hip total BMD was age dependent. In participants aged > or =70 years, the exercise significantly increased hip total BMD.

  15. Economic Analysis of 4221 Revisions Due to Periprosthetic Joint Infection in Poland.

    PubMed

    Babiak, Ireneusz; Pędzisz, Piotr; Janowicz, Jakub; Kulig, Mateusz; Małdyk, Paweł

    2017-01-26

    Periprosthetic joint infection (PJI) is one of the most severe complications of total hip (THA) and total knee (TKA) arthroplasty. The aim of the study is to determine the number and type of hip and knee prosthesis revisions in Poland performed due to infection and reimbursement of the cost of septic revisions and to compare the costs of septic and aseptic revisions in Poland and other countries. The data published for the period 2009-2013 by the National Health Fund (NHF) were analysed and the average cost of septic and aseptic revisions was calculated. In the years 2009-2013, a total of 260,030 hip and knee arthroplasties including 23,027 revisions (incl. 4,221 septic) were performed in Poland. In 2013, septic revisions accounted for 1.38% of all hip replacement procedures, 2.56% of all knee replacement procedures and 14.67% of all hip revisions and 30.23% of all knee revisions. In 2013, the difference between the average cost incurred by the hospital and the NHF refund for septic revision due to PJI was at least €238 and the cost-refund gap for the entire year was €219198. 1. The system of reporting periprostheticjoint infections currently in use in Poland does not adequately reflect the current classification of PJI and reimbursement for septic revision of joint prosthesis does not match the actual costs. 2. The Polish DRG system does not distinguish between early and late PJI and fails to acknowledge basic guidelines for infection treatment currently followed in Poland and worldwide. 3. According to the DRG system, patients requiring different treatment are placed in one category. 4. Until the year 2013, the less expensive treatment of early infections had been reimbursed on the same basis as the more costly two-stage revision procedures.

  16. Bilaterally Primary Cementless Total Hip Arthroplasty for Severe Hip Ankylosis with Ankylosing Spondylitis.

    PubMed

    Feng, Dong-Xu; Zhang, Kun; Zhang, Yu-Min; Nian, Yue-Wen; Zhang, Jun; Kang, Xiao-Min; Wu, Shu-Fang; Zhu, Yang-Jun

    2016-08-01

    Total hip arthroplasty is a reliable therapeutic intervention in patients with ankylosing spondylitis, in whom the aims of surgery are to reduce pain, restore hip function and improve quality of life. The current study is a retrospective analysis of the clinical and radiographic findings in a consecutive series of patients with hip ankylosis associated with severe ankylosing spondylitis who underwent bilateral primary total hip arthroplasty using non-cemented components. From June 2008 to May 2012, total hip arthroplasty was performed on 34 hips in 17 patients with bilateral ankylosis caused by ankylosing spondylitis. The study patients included 13 men and 4 women with a mean age of 24.2 years. The mean duration of disease was 8.3 years and the average duration of hip involvement was 7.6 years. All patients had severe hip pain and dysfunction with bilateral bony ankylosis and no range of motion preoperatively and all underwent bilateral cementless total hip arthroplasty performed by a single surgeon. Joint pain, range of motion (ROM), and Harris hip scores were assessed to evaluate the postoperative results. At a mean follow-up of 31.7 months, all patients had experienced significant clinical improvement in function, ROM, posture and ambulation. At the final follow-up, the mean postoperative flexion ROM was 134.4° compared with 0° preoperatively. Similar improvements were seen in hip abduction, adduction, internal rotation and external rotation. Postoperatively, 23 hips were completely pain-free, six had only occasional discomfort, three mild to moderate pain and two severe pain. The average Harris Hip Score improved from 23.7 preoperatively to 65.8 postoperatively. No stems had loosened at the final follow-up in any patient, nor had any revision surgery been required. Bilateral severe hip ankylosis in patients with ankylosing spondylitis can be treated with cementless bilateral synchronous total hip arthroplasty, which can greatly improve hip joint function and relieve pain without significant complications. Provided the overall physical condition of a patient and their economic situation make surgery a feasible option and the surgeon is experienced, this treatment is a worthwhile surgical intervention for bilateral hip bony ankylosis. However, the technically demanding nature of the procedure and potential pre- and post-operative problems should not be underestimated. © 2016 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  17. The validation of the visual analogue scale for patient satisfaction after total hip arthroplasty.

    PubMed

    Brokelman, Roy B G; Haverkamp, Daniel; van Loon, Corné; Hol, Annemiek; van Kampen, Albert; Veth, Rene

    2012-06-01

    INTRODUCTION: Patient satisfaction becomes more important in our modern health care system. The assessment of satisfaction is difficult because it is a multifactorial item for which no golden standard exists. One of the potential methods of measuring satisfaction is by using the well-known visual analogue scale (VAS). In this study, we validated VAS for satisfaction. PATIENT AND METHODS: In this prospective study, we studied 147 patients (153 hips). The construct validity was measured using the Spearman correlation test that compares the satisfaction VAS with the Harris hip score, pain VAS at rest and during activity, Oxford hip score, Short Form 36 and Western Ontario McMaster Universities Osteoarthritis Index. The reliability was tested using the intra-class coefficient. RESULTS: The Pearson correlation test showed correlations in the range of 0.40-0.80. The satisfaction VAS had a high correlation between the pain VAS and Oxford hip score, which could mean that pain is one of the most important factors in patient satisfaction. The intra-class coefficient was 0.95. CONCLUSIONS: There is a moderate to mark degree of correlation between the satisfaction VAS and the currently available subjective and objective scoring systems. The intra-class coefficient of 0.95 indicates an excellent test-retest reliability. The VAS satisfaction is a simple instrument to quantify the satisfaction of a patient after total hip arthroplasty. In this study, we showed that the satisfaction VAS has a good validity and reliability.

  18. Total hip arthroplasty in patients with dwarfism.

    PubMed

    Sekundiak, Todd D

    2005-09-01

    Skeletal dysplasia or dwarfism presents in a host of manners. Degenerative hip disease can present as a primary problem secondary to the abnormal growth disturbance or secondarily from the abnormal load distributions through the hip joint itself. Total hip arthroplasty is a successful procedure but sought with increased risks and complications when compared to routine hip arthroplasty. Custom or modular hip implants can help a surgeon manage the abnormal bone morphology seen with this condition.

  19. Two-Stage Progressive Femoral Lowering Followed by Cementless Total Hip Arthroplasty for Treating Crowe IV-Hartofilakidis Type 3 Developmental Dysplasia of the Hip.

    PubMed

    Binazzi, Roberto

    2015-05-01

    High developmental dysplasia of the hip is commonly treated with total hip arthroplasty and shortening osteotomy. We present a two stage technique, consisting of progressive femoral lowering followed by total hip arthroplasty. The clinico-radiographic results of eleven patients (twelve hips) who were operated on with the two-stage technique were evaluated at a mean follow-up of 11 ± 5 years. At the final follow-up, ten patients (eleven hips) had a mean Harris hip score of 85 ± 5 points with no implant loosening. One patient (one hip) was revised at 5 years due to infection. No neurovascular complications were observed in any patients. With this technique, we could place the cup in the anatomical position and obtain complete limb symmetry with excellent clinical results at long-term. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Surgery-Induced Changes and Early Recovery of Hip-Muscle Strength, Leg-Press Power, and Functional Performance after Fast-Track Total Hip Arthroplasty: A Prospective Cohort Study

    PubMed Central

    Holm, Bente; Thorborg, Kristian; Husted, Henrik; Kehlet, Henrik; Bandholm, Thomas

    2013-01-01

    Background By measuring very early changes in muscle strength and functional performance after fast-track total hip arthroplasty (THA), post-operative rehabilitation, introduced soon after surgery, can be designed to specifically target identified deficits. Objective(s) Firstly, to quantify changes (compared to pre-operative values) in hip muscle strength, leg-press power, and functional performance in the first week after THA, and secondly, to explore relationships between the muscle strength changes, and changes in hip pain, systemic inflammation, and thigh swelling. Design Prospective, cohort study. Setting Convenience sample of patients receiving a THA at Copenhagen University Hospital, Hvidovre, Denmark, between March and December 2011. Participants Thirty-five patients (65.9±7.2 years) undergoing THA. Main outcome measures Hip muscle strength, leg-press power, performance-based function, and self-reported disability were determined prior to, and 2 and 8 days after, THA (Day 2 and 8, respectively). Hip pain, thigh swelling, and C-Reactive Protein were also determined. Results Five patients were lost to follow-up. Hip muscle strength and leg press power were substantially reduced at Day 2 (range of reductions: 41–58%, P<0.001), but less pronounced at Day 8 (range of reductions: 23–31%, P<0.017). Self-reported symptoms and function (HOOS: Pain, Symptoms, and ADL) improved at Day 8 (P<0.014). Changes in hip pain, C-Reactive Protein, and thigh swelling were not related to the muscle strength and power losses. Conclusion(s) Hip muscle strength and leg-press power decreased substantially in the first week after THA – especially at Day 2 – with some recovery at Day 8. The muscle strength loss and power loss were not related to changes in hip pain, systemic inflammation, or thigh swelling. In contrast, self-reported symptoms and function improved. These data on surgery-induced changes in muscle strength may help design impairment-directed, post-operative rehabilitation to be introduced soon after surgery. Trial Registration ClinicalTrials.gov NCT01246674. PMID:23614020

  1. [Influence of Training of Orthopaedic Surgeons on Clinical Outcome after Total Hip Arthroplasty in a High Volume Endoprosthetic Centre].

    PubMed

    Osmanski-Zenk, Katrin; Finze, Susanne; Lenz, Robert; Bader, Rainer; Mittelmeier, Wolfram

    2018-06-26

    The study aims to evaluate whether the postoperative outcome and the probability of complications of patients with total hip arthroplasty increases significantly when surgeons in training are in charge, assisted by a high volume surgeon, compared to a highly experienced orthopaedic surgeon, within the context of a high volume hospital certified to EndoCert. 192 patients with a primary hip arthroplasty were included. To assess the outcome, the Harris Hip Score, WOMAC, SF-36 and EuroQol-5D were surveyed pre- and 12 months postoperatively. As complications we considered the quality indicators defined by EndoCert. We found significant improvements in the postoperative score values with the qualifications of the surgeon in charge, even when a high volume surgeon or a surgeon in training was responsible. If a surgeon in training is assisted by a highly experienced surgeon, the risk of complications does not increase, although the operating time was significantly increased. Both the surgeon in training as well as the arthroplasty patient benefit from implementing the EndoCert system, because the postoperative outcome and the complication probability is independent of the qualifcation of the operating orthopaedic surgeon performing total hip arthroplasty when assisted by an experienced surgeon. Georg Thieme Verlag KG Stuttgart · New York.

  2. Modular femoral component for conversion of previous hip surgery in total hip arthroplasty.

    PubMed

    Goldstein, Wayne M; Branson, Jill J

    2005-09-01

    The conversion of previous hip surgery to total hip arthroplasty creates a durable construct that is anatomically accurate. Most femoral components with either cemented or cementless design have a fixed tapered proximal shape. The proximal femoral anatomy is changed due to previous hip surgery for fixation of an intertrochanteric hip fracture, proximal femoral osteotomy, or a fibular allograft for avascular necrosis. The modular S-ROM (DePuy Orthopaedics Inc., Warsaw, Ind) hip stem accommodates these issues and independently prepares the proximal and distal portion of the femur. In preparation and implantation, the S-ROM hip stem creates less hoop stresses on potentially fragile stress risers from screws and thin bone. The S-ROM hip stem also prepares a previously distorted anatomy by milling through cortical bone that can occlude the femoral medullar canals and recreate proper femoral anteversion and reduces the risk of intraoperative or postoperative periprosthetic fracture due to the flexible titanium-slotted stem. The S-ROM femoral stem is recommended for challenging total hip reconstructions.

  3. [Revision hip arthroplasty by Waldemar Link custom-made total hip prosthesis].

    PubMed

    Medenica, Ivica; Luković, Milan; Radoicić, Dragan

    2010-02-01

    The number of patients undergoing hip arthroplasty revision is constantly growing. Especially, complex problem is extensive loss of bone stock and pelvic discontinuity that requires reconstruction. The paper presented a 50-year old patient, who ten years ago underwent a total cement artrhroplasty of the left hip. A year after the primary operation the patient had difficulties in walking without crutches. Problems intensified in the last five years, the patient had severe pain, totally limited movement in the left hip and could not walk at all. Radiographically, we found loose femoral component, massive loss of bone stock of proximal femur, acetabular protrusion and a consequent pelvic discontinuity. Clinically, a completely disfunctional left hip joint was registered (Harris hip score--7.1). We performed total rearthroplasty by a custom-made Waldemar Link total hip prosthesis with acetabular antiprotrusio cage and compensation of bone defects with a graft from the bone bank. A year after the operation, we found clinically an extreme improvement in Harris hip score--87.8. Radiographically, we found stability of implanted components, a complete graft integration and bone bridging across the site of pelvic discontinuity. Pelvic discontinuity and massive loss of proximal femoral bone stock is a challenging and complex entity. Conventional prostheses cannot provide an adequate fixation and stability of the hip. Application of custom-made prosthesis (measured specificaly for a patient) and additional alografting bone defects is a good method in revision surgery after unsuccessful hip arthroplasty with extensive bone defects.

  4. The effect of total hip and hip resurfacing arthroplasty on vertical ground reaction force and impulse symmetry during a sit-to-stand task.

    PubMed

    Caplan, N; Stewart, S; Kashyap, S; Banaszkiewicz, P; St Clair Gibson, A; Kader, D; Ewen, A

    2014-12-01

    The aim of this study was to determine the influence of total hip arthroplasty and hip resurfacing arthroplasty on limb loading symmetry before, and after, hip reconstruction surgery during a sit-to-stand task. Fourteen patients were recruited that were about to receive either a total hip prosthesis (n=7) or a hip resurfacing prosthesis (n=7), as well as matched controls. Patients performed a sit-to-stand movement before, 3 months after, and 12 months after surgery. Peak vertical ground reaction force and impulse were measured for each leg, from which ground reaction force and impulse symmetry ratios were calculated. Before surgery, hip resurfacing patients showed a small asymmetry which was not different to normal for ground reaction force (0.88(0.28) vs. 1.00(0.11); p=0.311) or impulse (0.87(0.29) vs. 0.99(0.09); p=0.324) symmetry ratios. Total hip patients offloaded their affected hip by 30% in terms of impulse symmetry ratio (0.71(0.36) vs. 0.99(0.23); p=0.018). At 3 months following surgery asymmetries were seen that were different to normal in both hip resurfacing patients for ground reaction force (0.77(0.16); p=0.007), and total hip patients for ground reaction force (0.70(0.15); p=0.018) and impulse (0.72(0.16); p=0.011) symmetry ratios. By 12 months after surgery total hip patients regained a symmetrical loading pattern for both ground reaction force (0.95(0.06); p=0.676) and impulse (1.00(0.06); p=0.702) symmetry ratios. Hip resurfacing patients, however, performed the task by overloading their operated hip, with impulse symmetry ratio being larger than normal (1.16(0.16); p=0.035). Physiotherapists should appreciate the need for early recovery of limb loading symmetry as well as subsequent differences in the responses observed with different prostheses. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Huntingtin interacting protein 1 as a histopathologic adjunct in the diagnosis of Merkel cell carcinoma.

    PubMed

    Marghalani, Siham; Feller, John Kyle; Mahalingam, Meera; Mirzabeigi, Marjan

    2015-06-01

    Huntington interacting protein 1 (HIP1), an antiapoptotic protein normally expressed in the brain, is highly expressed in Merkel cell carcinomas (MCCs). Given this, the aim of the current study was to ascertain the value of HIP1 as a histopathologic adjunct in the diagnosis of MCC. In this retrospective study, archival material from 26 cases with a diagnosis of MCC and/or neuroendocrine carcinoma were retrieved from the pathology files of the Skin Pathology Laboratory (Boston University School of Medicine, Boston, MA, USA). Histopathologic sections of all cases were re-reviewed and the diagnosis confirmed. All patient data were de-identified. Immunohistochemical studies were performed using antibodies to HIP1 and cytokeratins (CK) 20 and 7. A semiquantitative scoring system for immunohistochemical expression of HIP1 was utilized by deriving a cumulative score (based on percentage positivity of cells and intensity of expression). Using a cut-off total score of 3 or more as positive, the total number of positive cases was 22 for HIP1, 24 for CK20, and 11 for CK7. Comparing the results of HIP1 and CK20, there were four discordant pairs (three positive for CK20 but negative for HIP1 and one positive for HIP1 but negative for CK20). McNemar's test indicated that there was no statistical significance (P = 0.625), thereby implying a close agreement between the expression of HIP1 and CK20 in these neuroendocrine neoplasms. © 2014 The International Society of Dermatology.

  6. [Evaluation of selected parameters of blood coagulation and fibrinolysis system in patients undergoing total hip replacement surgery with normovolemic hemodilution procedure and standard enoxaparine prophylaxis].

    PubMed

    Piecuch, Wiesław; Sokołowska, Bozena; Dmoszyńska, Anna; Furmanik, Franciszek

    2003-01-01

    The aim of the study was to evaluate selected blood coagulation and fibrinolysis parameters in patients undergoing total hip replacement surgery with normovolemic hemodilution and standard enoksaparine profilaxis. The study included 66 patients undergoing hip replacement surgery. The group consisted of 51 women and 15 men, within the age range of 47-78, the mean age was 64. In 32 (subgroup II) patients the surgery was performed with the use of normovolemic hemodilution, in 34 (subgroup I) the hemodilution procedure was not applied. The enoksaparine as prophylaxis started 12 hours prior to surgery and continued during hospitalisation. The examination of the coagulation system was performed: on the day of the operation in the morning, on the day of the operation in the evening and on the first day after operation. We determined the concentrations of TAT and PAP complexes, prothrombin fragments 1 + 2 (F1 + 2) and d-dimers (DD). 1) during total hip replacement surgery and particularly in the period of the first 12 hours after the procedure marked activation of coagulation and fibrinolysis occurRed; 2) the application of the hemodilution procedure does not influence significantly the degree of coagulation and fibrinolysis disorders in the perioperative period, but could reduced incidence of thromboembolic complications in the postoperative period.

  7. The effect of dynamic hip motion on the micromotion of press-fit acetabular cups in six degrees of freedom.

    PubMed

    Crosnier, Emilie A; Keogh, Patrick S; Miles, Anthony W

    2016-08-01

    The hip joint is subjected to cyclic loading and motion during activities of daily living and this can induce micromotions at the bone-implant interface of cementless total hip replacements. Initial stability has been identified as a crucial factor to achieve osseointegration and long-term survival. Whilst fixation of femoral stems achieves good clinical results, the fixation of acetabular components remains a challenge. In vitro methods assessing cup stability keep the hip joint in a fixed position, overlooking the effect of hip motion. The effect of hip motion on cup micromotion using a hip motion simulator replicating hip flexion-extension and a six degrees of freedom measurement system was investigated. The results show an increase in cup micromotion under dynamic hip motion compared to Static Flexion. This highlights the need to incorporate hip motion and measure all degrees of freedom when assessing cup micromotion. In addition, comparison of two press-fit acetabular cups with different surface coatings suggested similar stability between the two cups. This new method provides a basis for a more representative protocol for future pre-clinical evaluation of different cup designs. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  8. Bearing Change to Metal-On-Polyethylene for Ceramic Bearing Fracture in Total Hip Arthroplasty; Does It Work?

    PubMed

    Lee, Soong Joon; Kwak, Hong Suk; Yoo, Jeong Joon; Kim, Hee Joong

    2016-01-01

    We evaluated the short-term to midterm results of reoperation with bearing change to metal-on-polyethylene (MoP) after ceramic bearing fracture in ceramic-on-ceramic total hip arthroplasty. Nine third-generation ceramic bearing fractures (6 heads and 3 liners) were treated with bearing change to MoP. Mean age at reoperation was 52.7 years. Mean follow-up was 4.3 years. During follow-up, 2 of 3 liner-fractured hips and 1 of 6 head-fractured hips showed radiologic signs of metallosis and elevated serum chromium levels. Re-reoperation with bearing rechange to a ceramic head was performed for the hips with metallosis. One liner-fractured hip had periprosthetic joint infection. Dislocation occurred in 3 hips. From our experience, bearing change to MoP is not a recommended treatment option for ceramic bearing fracture in total hip arthroplasty. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Newer anesthesia and rehabilitation protocols enable outpatient hip replacement in selected patients.

    PubMed

    Berger, Richard A; Sanders, Sheila A; Thill, Elizabeth S; Sporer, Scott M; Della Valle, Craig

    2009-06-01

    Advancements in the surgical approach, anesthetic technique, and the initiation of rapid rehabilitation protocols have decreased the duration of hospitalization and subsequent length of recovery following elective total hip arthroplasty. We assessed the feasibility and safety of outpatient total hip arthroplasty in 150 consecutive patients. A comprehensive perioperative anesthesia and rehabilitation protocol including preoperative teaching, regional anesthesia, and preemptive oral analgesia and antiemetic therapy was implemented around a minimally invasive surgical technique. A rapid rehabilitation pathway was started immediately after surgery and patients had the option of being discharged to home the day of surgery if standard discharge criteria were met. All 150 patients were discharged to home the day of surgery, at which time 131 patients were able to walk without assistive devices. Thirty-eight patients required some additional intervention outside the pathway to resolve nausea, hypotension, or sedation prior to discharge. There were no readmissions for pain, nausea, or hypotension yet there was one readmission for fracture and nine emergency room evaluations in the three month perioperative period. This anesthetic and rehabilitation protocol allowed outpatient total hip arthroplasty to be routinely performed in these consecutive patients undergoing primary total hip arthroplasty. With current reimbursement approaches the modest savings to the hospital in length of stay may be outweighed by the additional costs of personnel, thereby making this outpatient system more expensive to implement. Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  10. Living history in current orthopaedic hip surgery: intrapelvic teflon granuloma after total hip replacement.

    PubMed

    Gheorghiu, Daniel; Peter, Viju; Lynch, Martin

    2010-02-01

    The teflon hip arthroplasty design was used by Sir John Charnley in the early 60's but was taken off the market due to high complication rates. A case is reported of an intrapelvic granuloma after total hip arthroplasty following the use of a teflon socket. This appears to be the last surviving patient treated by Sir John Charnley using a Teflon hip socket design.

  11. Should gram stains have a role in diagnosing hip arthroplasty infections?

    PubMed

    Johnson, Aaron J; Zywiel, Michael G; Stroh, D Alex; Marker, David R; Mont, Michael A

    2010-09-01

    The utility of Gram stains in diagnosing periprosthetic infections following total hip arthroplasty has recently been questioned. Several studies report low sensitivity of the test, and its poor ability to either confirm or rule out infection in patients undergoing revision total hip arthroplasty. Despite this, many institutions including that of the senior author continue to perform Gram stains during revision total hip arthroplasty. We assessed the sensitivity, specificity, accuracy, and positive and negative predictive values of Gram stains from surgical-site samplings taken from procedures on patients with both infected and aseptic revision total hip arthroplasties. A review was performed on patients who underwent revision total hip arthroplasty between 2000 and 2007. Eighty-two Gram stains were performed on patients who had infected total hip arthroplasties and underwent revision procedures. Additionally, of the 410 revision total hip arthroplasties performed on patients who were confirmed infection-free, 120 Gram stains were performed. Patients were diagnosed as infected using multiple criteria at the time of surgery. Sensitivity, specificity, positive and negative predictive values, and accuracy were calculated from these Gram stain results. The Gram stain demonstrated a sensitivity and specificity of 9.8% and 100%, respectively. In this series, the Gram stain had a negative predictive value of 62%, a positive predictive value of 100%, and an accuracy of 63%. Gram stains obtained from surgical-site samples had poor sensitivity and poor negative predictive value. Based on these findings, as well as those of other authors, we believe that Gram stains should no longer be considered for diagnosing infections in revision total hip arthroplasty. Level III, diagnostic study. See Guidelines for Authors for a complete description of levels of evidence.

  12. Sexual activity after total hip replacement in Korean patients: how they do, what they want, and how to improve.

    PubMed

    Yoon, Byung-Ho; Lee, Kyung-Hag; Noh, Serae; Ha, Yong-Chan; Lee, Young-Kyun; Koo, Kyung-Hoi

    2013-12-01

    Concerns of patients on sexual activity after total hip arthroplasty have not been well studied in Asian patients. This study aimed to determine the following: (1) what are the concerns of patients related to sexual activity after total hip arthroplasty? (2) what are the changes in sexual activity after total hip replacement in Korean patients? Details of sexual activity and concerns were obtained using a questionnaire designed specifically for the study. The questionnaire was administered to 64 patients in a face-to-face interview at an outpatient clinic. Preoperatively, 53.1% of patients experienced difficulties, primarily due to hip pathology and limitations of motion. The median time to the resumption of sexual activity was 3 months postoperatively, and most patients had no increase in the frequency of sexual activity after the total hip replacement. In 39.1% of patients were seen having difficulties with leg positioning following total hip replacement, and they were likely to change coital positions. The most common concern regarding sexual activity of patients was the fear of dislocation. Furthermore, patients with a higher stress level had lower satisfaction rates. Most patients were unable to obtain information on sexual activity following the total hip arthroplasty, and they did not consult with a physician due to the private nature of the topic. Dislocation was the most common concern of patients during sexual activity following a total hip arthroplasty, and a higher stress level was found to be associated with a lower satisfaction rate. Because most patients were unprepared to consult a physician, the provision of appropriate information before a consultation might be beneficial.

  13. Sexual Activity after Total Hip Replacement in Korean Patients: How They Do, What They Want, and How to Improve

    PubMed Central

    Yoon, Byung-Ho; Lee, Kyung-Hag; Noh, Serae; Ha, Yong-Chan; Koo, Kyung-Hoi

    2013-01-01

    Background Concerns of patients on sexual activity after total hip arthroplasty have not been well studied in Asian patients. This study aimed to determine the following: (1) what are the concerns of patients related to sexual activity after total hip arthroplasty? (2) what are the changes in sexual activity after total hip replacement in Korean patients? Methods Details of sexual activity and concerns were obtained using a questionnaire designed specifically for the study. The questionnaire was administered to 64 patients in a face-to-face interview at an outpatient clinic. Results Preoperatively, 53.1% of patients experienced difficulties, primarily due to hip pathology and limitations of motion. The median time to the resumption of sexual activity was 3 months postoperatively, and most patients had no increase in the frequency of sexual activity after the total hip replacement. In 39.1% of patients were seen having difficulties with leg positioning following total hip replacement, and they were likely to change coital positions. The most common concern regarding sexual activity of patients was the fear of dislocation. Furthermore, patients with a higher stress level had lower satisfaction rates. Most patients were unable to obtain information on sexual activity following the total hip arthroplasty, and they did not consult with a physician due to the private nature of the topic. Conclusions Dislocation was the most common concern of patients during sexual activity following a total hip arthroplasty, and a higher stress level was found to be associated with a lower satisfaction rate. Because most patients were unprepared to consult a physician, the provision of appropriate information before a consultation might be beneficial. PMID:24340146

  14. Bone-preserving total hip arthroplasty in avascular necrosis of the hip-a matched-pairs analysis.

    PubMed

    Merschin, David; Häne, Richard; Tohidnezhad, Mersedeh; Pufe, Thomas; Drescher, Wolf

    2018-07-01

    Short-stem hip arthroplasty has the potential advantage of femoral bone stock preservation, especially in view of the expected revisions in the often relatively young patients. Despite short-stem hip prosthesis are increasingly used for total hip arthroplasty, there are no sufficient mid- and long-term results especially for patients with avascular femoral head osteonecrosis. The present study investigates mid-term functional results as well as the revision rate following implantation of a short-stem prosthesis. In the period 06/2005 until 12/2013, a total of 351 short-stem hip prostheses were implanted. The study included 331 complete data sets. A retrospective analysis was performed using the Oxford Hip Score. All revisions were registered. In a total of 331 prostheses, the Oxford Hip Score was "excellent" in 66.2%, "good" in 12.7%, "fair" in 13.0%, and "poor" in 8.2% with a mean follow-up of 57.4 months (SD ± 29.8; range 24-115). In 26 cases, aseptic osteonecrosis of the hip was the indication (7.9%). The Oxford Hip Score was "excellent" in 66.7%, "good" in 0.0%, "fair" in 20.8%, and "poor" in 12.5%. The cumulated five year survival rate was 96.7%. In mid-term observation, the Metha® short-stem prosthesis shows no disadvantage in functional outcome and in survival time compared to a standard hip stem. Providing a correct indication, the Metha® short stem is a valuable option in total hip arthroplasty for younger patients with avascular osteonecrosis of the femoral head. Evaluation has shown no significant differences between aseptic osteonecrosis and other indications.

  15. Effectiveness of an interactive telerehabilitation system with home-based exercise training in patients after total hip or knee replacement: study protocol for a multicenter, superiority, no-blinded randomized controlled trial.

    PubMed

    Eichler, Sarah; Rabe, Sophie; Salzwedel, Annett; Müller, Steffen; Stoll, Josefine; Tilgner, Nina; John, Michael; Wegscheider, Karl; Mayer, Frank; Völler, Heinz

    2017-09-21

    Total hip or knee replacement is one of the most frequently performed surgical procedures. Physical rehabilitation following total hip or knee replacement is an essential part of the therapy to improve functional outcomes and quality of life. After discharge from inpatient rehabilitation, a subsequent postoperative exercise therapy is needed to maintain functional mobility. Telerehabilitation may be a potential innovative treatment approach. We aim to investigate the superiority of an interactive telerehabilitation intervention for patients after total hip or knee replacement, in comparison to usual care, regarding physical performance, functional mobility, quality of life and pain. This is an open, randomized controlled, multicenter superiority study with two prospective arms. One hundred and ten eligible and consenting participants with total knee or hip replacement will be recruited at admission to subsequent inpatient rehabilitation. After comprehensive, 3-week, inpatient rehabilitation, the intervention group performs a 3-month, interactive, home-based exercise training with a telerehabilitation system. For this purpose, the physiotherapist creates an individual training plan out of 38 different strength and balance exercises which were implemented in the system. Data about the quality and frequency of training are transmitted to the physiotherapist for further adjustment. Communication between patient and physiotherapist is possible with the system. The control group receives voluntary, usual aftercare programs. Baseline assessments are investigated after discharge from rehabilitation; final assessments 3 months later. The primary outcome is the difference in improvement between intervention and control group in 6-minute walk distance after 3 months. Secondary outcomes include differences in the Timed Up and Go Test, the Five-Times-Sit-to-Stand Test, the Stair Ascend Test, the Short-Form 36, the Western Ontario and McMaster Universities Osteoarthritis Index, the International Physical Activity Questionnaire, and postural control as well as gait and kinematic parameters of the lower limbs. Baseline-adjusted analysis of covariance models will be used to test for group differences in the primary and secondary endpoints. We expect the intervention group to benefit from the interactive, home-based exercise training in many respects represented by the study endpoints. If successful, this approach could be used to enhance the access to aftercare programs, especially in structurally weak areas. German Clinical Trials Register (DRKS), ID: DRKS00010009 . Registered on 11 May 2016.

  16. Patient-specific musculoskeletal modeling of the hip joint for preoperative planning of total hip arthroplasty: A validation study based on in vivo measurements

    PubMed Central

    Schick, Fabian; Asseln, Malte; Damm, Philipp; Radermacher, Klaus

    2018-01-01

    Validation of musculoskeletal models for application in preoperative planning is still a challenging task. Ideally, the simulation results of a patient-specific musculoskeletal model are compared to corresponding in vivo measurements. Currently, the only possibility to measure in vivo joint forces is to implant an instrumented prosthesis in patients undergoing a total joint replacement. In this study, a musculoskeletal model of the AnyBody Modeling System was adapted patient-specifically and validated against the in vivo hip joint force measurements of ten subjects performing one-leg stance and level walking. The impact of four model parameters was evaluated; hip joint width, muscle strength, muscle recruitment, and type of muscle model. The smallest difference between simulated and in vivo hip joint force was achieved by using the hip joint width measured in computed tomography images, a muscle strength of 90 N/cm2, a third order polynomial muscle recruitment, and a simple muscle model. This parameter combination reached mean deviations between simulation and in vivo measurement during the peak force phase of 12% ± 14% in magnitude and 11° ± 5° in orientation for one-leg stance and 8% ± 6% in magnitude and 10° ± 5° in orientation for level walking. PMID:29649235

  17. Hip Rotation Range of Motion in People With and Without Low Back Pain Who Participate in Rotation-Related Sports

    PubMed Central

    Van Dillen, Linda R.; Bloom, Nancy J.; Gombatto, Sara P.; Susco, Thomas M.

    2008-01-01

    Objective To examine whether passive hip rotation motion was different between people with and without low back pain (LBP) who regularly participate in sports that require repeated rotation of the trunk and hips. We hypothesized that people with LBP would have less total hip rotation motion and more asymmetry of motion between sides than people without LBP. Design Two group, case-control. Setting University-based musculoskeletal analysis laboratory. Participants Forty-eight subjects (35 males, 13 females; mean age: 26.56±7.44 years) who reported regular participation in a rotation-related sport participated. Two groups were compared; people with LBP (N=24) and people without LBP (N=24; NoLBP). Main outcome measures Data were collected on participant-related, LBP-related, sport-related and activity-related variables. Measures of passive hip rotation range of motion were obtained. The differences between the LBP and NoLBP groups were examined. Results People with and without a history of LBP were the same with regard to all participant-related, sport-related and activity-related variables. The LBP group had significantly less total rotation (P=.035) and more asymmetry of total rotation, right hip versus left hip, (P=.022) than the NoLBP group. Left total hip rotation was more limited than right total hip rotation in the LBP group (P=.004). There were no significant differences in left and right total hip rotation for the NoLBP group (P=.323). Conclusions Among people who participate in rotation-related sports, those with LBP had less overall passive hip rotation motion and more asymmetry of rotation between sides than people without LBP. These findings suggest that the specific directional demands imposed on the hip and trunk during regularly performed activities may be an important consideration in deciding which impairments may be most relevant to test and to consider in prevention and intervention strategies. PMID:19081817

  18. Complications of porous-coated press-fit cementless total hip replacement in dogs.

    PubMed

    Kidd, Scott W; Preston, Christopher A; Moore, George E

    2016-09-20

    To report postoperative complications using a commercially available porous-coated press-fit cementless total hip replacement (THR) system in dogs. Medical records were reviewed for client-owned dogs with hip pathologies requiring THR. A minimum of six-week postoperative orthopaedic examination and orthogonal pelvic radiographs were used to assess outcome and complications in the perioperative period. Referring veterinarian medical records, phone interviews with clients, or both were used to assess long-term functional outcome and complications. Bilateral THR was performed in 36 dogs, and unilateral in 147 dogs, making a total of 219 THR procedures in 183 dogs. A total complication rate of 31.1% (68/219) was observed. A catastrophic complication was observed in 8.2% (n = 18), a major complication in 9.6% (n = 21), and a minor complication in 13.2% (n = 29) of procedures. The most common complications were intra-operative femoral fissure (n = 46), diaphyseal femoral fracture (n = 15), and coxofemoral luxation (n = 9). Full return to function was achieved in 88.1% of procedures with a median follow-up period of 42 months. Porous-coated press-fit cementless collarless total hip replacements have a high complication rate. The majority of complications occur intra-operatively or perioperatively, with few complications occurring beyond 12 weeks postoperatively. Both fissure fractures and diaphyseal femoral fractures carry a favourable prognosis with immediate cerclage wiring and plate fixation, respectively.

  19. [Comparison of early clinical effects of two hip prosthesis designs between ceramics to ceramics and metal to polyethylene].

    PubMed

    Yang, Li-qing; Li, Xi; Fu, Qin; Wang, Cheng

    2013-07-01

    To retrospectively study early therapeutic effects of the ceramics to ceramics prosthesis design in treating hip disease. From October 2007 to September 2010, 42 patients (44 hips) with hip disease underwent replacement of total hip. Hip prosthesis designs included the Pinnacle ceramics to ceramics and the Duraloc metal to polyethylene,produced by DePuy Company, all were non-bone cement type of artificial hip joint. Twenty patients (22 hips) were performed with ceramics to ceramics total hip prosthesis (CoC group, there were 12 males and 8 females, aged from 21 to 49 years) and 22 patients (22 hips) were performed with metal to polyethylene total hip prosthesis (MoP group, there were 13 males and 9 females, aged from 42 to 55 years). All the surgical approachs were posterolateral, and the routine anticoagulation and the corresponding functional exercise were performed after operation. The follow-up time was 6 months at least including clinical and radiographic observation. Measured the motion of joint and evaluated the function of hip joint according to Harris classification. All clinical effects were satisfactory and no dislocation ,loosening,infection, deep venous thrombosis and other complications occurred. There was no statistical significance in Harris scoring and the motion of joint between two groups before and after operation (P>0.05). The clinical effect of ceramics to ceramics prosthesis design in improving clinical symptoms and the motion of joint is coordinate with metal to polyethylene total hip prosthesis, however, its advantages and long-term efficacy need further observing. The ceramics to ceramics prosthesis design may be a good choice for the young patients with hip disease because of its good wear resistance.

  20. Perioperative Pain Management in Total Hip Arthroplasty: Korean Hip Society Guidelines

    PubMed Central

    Kim, Yeesuk; Cho, Hong-Man; Park, Kyung-Soon; Yoon, Pil Whan; Nho, Jae-Hwi; Kim, Sang-Min; Lee, Kyung-Jae; Moon, Kyong-Ho

    2016-01-01

    Effective perioperative pain management techniques and accelerated rehabilitation programs can improve health-related quality of life and functional status of patients after total hip arthroplasty. Traditionally, postoperative analgesia following arthroplasty was provided by intravenous patient-controlled analgesia or epidural analgesia. Recently, peripheral nerve blockade has emerged alternative analgesic approach. Multimodal analgesia strategy combines analgesics with different mechanisms of action to improve pain management. Intraoperative periarticular injection of multimodal drugs is one of the most important procedures in perioperative pain control for total hip arthroplasty. The goal of this review article is to provide a concise overview of the principles of multimodal pain management regimens as a practical guide for the perioperative pain management for total hip arthroplasty. PMID:27536639

  1. Lean mass and fat mass predict bone mineral density in middle-aged individuals with noninsulin-requiring type 2 diabetes mellitus.

    PubMed

    Moseley, Kendall F; Dobrosielski, Devon A; Stewart, Kerry J; De Beur, Suzanne M Jan; Sellmeyer, Deborah E

    2011-05-01

    Despite high bone mineral density (BMD), persons with type 2 diabetes are at greater risk of fracture. The relationship between body composition and BMD in noninsulin-requiring diabetes is unclear. The aim was to examine how fat and lean mass independently affect the skeleton in this population. Subjects for this cross-sectional analysis were men (n = 78) and women (n = 56) aged 40-65 years (56 ± 6 years) with uncomplicated, noninsulin-requiring type 2 diabetes. Total body fat and lean mass, total body, hip and lumbar spine BMD were measured with dual energy X-ray absorptiometry. Magnetic resonance imaging measured total abdominal, visceral and subcutaneous (SQ) fat. Subjects had normal all-site BMD and were obese to overweight (body mass index 29-41 kg/m(2)) with controlled diabetes (HbA1c women 6·6 ± 1·2%, men 6·7 ± 1·6%). Lean mass was positively associated with total body, hip, femoral neck and hip BMD in both sexes. Fat mass, abdominal total and SQ fat were associated with total body and hip BMD in women. In multivariate analyses adjusted for sex, lean mass significantly predicted total, hip and femoral neck BMD in men and women. In unadjusted models, lean mass continued to predict BMD at these sites in men; fat mass also predicted total body, femoral and hip BMD in women. In men and women with uncomplicated, noninsulin-requiring diabetes, lean mass significantly predicted BMD at the total body, hip and femoral neck. Further research is needed to determine whether acquisition or maintenance of lean mass in T2DM can prevent hip fracture in this at-risk population. © 2011 Blackwell Publishing Ltd.

  2. Migration characteristics and early clinical results of the NANOS® short-stem hip arthroplasty.

    PubMed

    Kaipel, Martin; Grabowiecki, Phillip; Sinz, Katrina; Farr, Sebastian; Sinz, Günter

    2015-05-01

    Femoral short stems promise essential advantages in total hip arthroplasty. Up to now, only short- and midterm clinical studies exist. Data on early stem migration that could predict later aseptic loosening at an early stage are rare. The purpose of this study was to assess migration patterns and clinical outcome 2 years after hip replacement by a metaphyseal anchored cementless short stem. Migration data and clinical results were prospectively assessed in 49 patients. Clinical outcome was measured using the Harris Hip Score (HHS). Migration analyses were performed using the computer-assisted Einzel-Bild-Roentgen-Analyse (EBRA) system. At 2 years after surgery, none of the implants needed revision, and HHS increased from 47.9 up to 98.1. Of 49 patients, 5 (10%) showed increased vertical stem migration (1.5 mm/2a) that might predict late aseptic loosening. Of 49 stems, 44 (90%) showed stable migration patterns indicating a beneficial long-term outcome. Results of this study confirm the excellent clinical data of previous works. Migration patterns strongly suggest that short-stem arthroplasty is not only an innovative but also a reliable strategy in total hip replacement.

  3. Manual calf massage and passive ankle motion reduce the incidence of deep vein thromboembolism after total hip arthroplasty.

    PubMed

    Imai, Norio; Ito, Tomoyuki; Suda, Ken; Miyasaka, Dai; Endo, Naoto

    2017-07-01

    Venous thromboembolism is one of the general complications following total hip arthroplasty, wherein various preventive treatments have been recommended. Several studies reported that venous thromboembolism incidence after total hip arthroplasty was similar in patients who were administered prophylaxis with a conventional mechanical procedure alone, and those who were administered pharmacological anticoagulation therapy. Therefore, the optimum methods of prophylaxis are still controversial. The purpose of this study was to investigate whether manual calf massage and passive ankle motion could lower the risk for venous thromboembolism after total hip arthroplasty. We retrospectively reviewed the data of 126 consecutive patients undergoing elective primary unilateral total hip arthroplasty wherein manual calf massage and passive ankle motion were performed after the surgery at our hospitals between January and October 2014. The 138 patients of the control group underwent total hip arthroplasty using the same surgical approach and pre- and postoperative protocols without this mechanical prophylaxis between January and December 2013. This mechanical prophylaxis was performed simultaneously 30 times during approximately 10 s; these procedures were repeated thrice immediately after total hip arthroplasty. Duplex ultrasonography was performed to observe the veins of both legs in all the patients on postoperative day 7. The incidence of deep vein thrombosis was 6.52% and 0.79% in the control and manual calf massage and passive ankle motion groups, respectively. The odds ratio for the manual calf massage and passive ankle motion groups was 8.72. Performing this mechanical prophylaxis reduced the incidence of venous thromboembolism after total hip arthroplasty. This mechanical prophylaxis is not only simple and easy, but is also safe and inexpensive. We therefore recommend that manual calf massage and passive ankle motion be performed in patients who will undergo total hip arthroplasty, if deep vein thrombosis does not exist before the surgery. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  4. Treatment of Crowe Type-IV Hip Dysplasia Using Cementless Total Hip Arthroplasty and Double Chevron Subtrochanteric Shortening Osteotomy: A 5- to 10-Year Follow-Up Study.

    PubMed

    Li, Xigong; Lu, Yang; Sun, Junying; Lin, Xiangjin; Tang, Tiansi

    2017-02-01

    The purpose of this study was to evaluate the functional and radiographic results of patients with Crowe type-IV hip dysplasia treated by cementless total hip arthroplasty and double chevron subtrochanteric osteotomy. From January 2000 to February 2006, cementless total hip arthroplasty with a double chevron subtrochanteric shortening osteotomy was performed on 18 patients (22 hips) with Crowe type-IV dysplasia. The acetabular cup was placed in the position of the anatomic hip center, and subtrochanteric femoral shortening osteotomy was performed with the use of a double chevron design. The clinical and radiographic outcomes were reviewed with a mean follow-up of 6.5 years (5-10 years). The mean amount of femoral subtrochanteric shortening was 38 mm (25-60 mm). All osteotomy sites were healed by 3-6 months without complications. The mean Harris Hip Score improved significantly from 47 points (35-65 points) preoperatively to 88 points (75-97 points) at the final follow-up. The Trendelenburg sign was corrected from a positive preoperative status to a negative postoperative status in 12 of 22 hips. No acetabular and femoral components have loosened or required revision during the period of follow-up. Cementless total hip arthroplasty using double chevron subtrochanteric osteotomy allowed for restoration of anatomic hip center with safely functional limb lengthening, achieved correction of preoperative limp, and good functional and radiographic outcomes for 22 Crowe type-IV dislocation hips at the time of the 5- to 10-year follow-up. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Relationship between ankle range of motion and Biodex Balance System in females and males.

    PubMed

    Sung, Eun-Sook; Kim, Jung-Hyun

    2018-02-01

    This study examined whether there are differences between range of motion (ROM) and balance in lower extremities according to gender. A total of 31 male and 28 female students measured plantar flexion (PF), dorsiflexion, inversion (IV), eversion (EV), hip flexion (HF), hip internal rotation (HIR), and hip external rotation (HER) and tested on the Biodex Balance System. ROM of PF and HF were significantly high the female group and ROMs of IV, EV, HIR, and HER were significantly higher the male group than in the female group. Low ROM of PF may be more negative related to overall balance, especially, back balance in males; therefore, it is necessary to assess and plan the training program for PF ROM in male students.

  6. Compatibility of the totally replaced hip. Reduction of wear by amorphous diamond coating.

    PubMed

    Santavirta, Seppo

    2003-12-01

    Particulate wear debris in totally replaced hips causes adverse local host reactions. The extreme form of such a reaction, aggressive granulomatosis, was found to be a distinct condition and different from simple aseptic loosening. Reactive and adaptive tissues around the totally replaced hip were made of proliferation of local fibroblast like cells and activated macrophages. Methylmethacrylate and high-molecular-weight polyethylene were shown to be essentially immunologically inert implant materials, but in small particulate form functioned as cellular irritants initiating local biological reactions leading to loosening of the implants. Chromium-cobalt-molybdenum is the most popular metallic implant material; it is hard and tough, and the bearings of this metal are partially self-polishing. In total hip implants, prerequisites for longevity of the replaced hip are good biocompatibility of the materials and sufficient tribological properties of the bearings. The third key issue is that the bearing must minimize frictional shear at the prosthetic bone-implant interface to be compatible with long-term survival. Some of the approaches to meet these demands are alumina-on-alumina and metal-on-metal designs, as well as the use of highly crosslinked polyethylene for the acetabular component. In order to avoid the wear-based deleterious properties of the conventional total hip prosthesis materials or coatings, the present work included biological and tribological testing of amorphous diamond. Previous experiments had demonstrated that a high adhesion of tetrahedral amorphous carbon coatings to a substrate can be achieved by using mixing layers or interlayers. Amorphous diamond was found to be biologically inert, and simulator testing indicated excellent wear properties for conventional total hip prostheses, in which either the ball or both bearing surfaces were coated with hydrogen-free tetrahedral amorphous diamond films. Simulator testing with such total hip prostheses showed no measurable wear or detectable delamination after 15,000,000 test cycles corresponding to 15 years of clinical use. The present work clearly shows that wear is one of the basic problems with totally replaced hips. Diamond coating of the bearing surfaces appears to be an attractive solution to improve longevity of the totally replaced hip.

  7. Comparison of outcome measures and complication rates following three different approaches for primary total hip arthroplasty: a pragmatic randomised controlled trial.

    PubMed

    Talia, Adrian J; Coetzee, Cassandra; Tirosh, Oren; Tran, Phong

    2018-01-08

    Total hip arthroplasty is one of the most commonly performed surgical procedures worldwide. There are a number of surgical approaches for total hip arthroplasty and no high-level evidence supporting one approach over the other. Each approach has its unique benefits and drawbacks. This trial aims to directly compare the three most common surgical approaches for total hip arthroplasty. This is a single-centre study conducted at Western Health, Melbourne, Australia; a large metropolitan centre. It is a pragmatic, parallel three-arm, randomised controlled trial. Sample size will be 243 participants (81 in each group). Randomisation will be secure, web-based and managed by an independent statistician. Patients and research team will be blinded pre-operatively, but not post-operatively. Intervention will be either direct anterior, lateral or posterior approach for total hip arthroplasty, and the three arms will be directly compared. Participants will be aged over 18 years, able to provide informed consent and recruited from our outpatients. Patients who are having revision surgery or have indications for hip replacement other than osteoarthritis (i.e., fracture, malignancy, development dysplasia) will be excluded from the trial. The Oxford Hip Score will be determined for patients pre-operatively and 6 weeks, 6, 12 and 24 months post-operatively. The Oxford Hip Score at 24 months will be the primary outcome measure. Secondary outcome measures will be dislocation, infection, intraoperative and peri-prosthetic fracture rate, length of hospital stay and pain level, reported using a visual analogue scale. Many studies have evaluated approaches for total hip arthroplasty and arthroplasty registries worldwide are now collecting this data. However no study to date has compared these three common approaches directly in a randomised fashion. No trial has used patient-reported outcome measures to evaluate success. This pragmatic study aims to identify differences in patient perception of total hip arthroplasty depending on surgical approach. Australian New Zealand Clinical Trials Registry, ACTRN12617000272392 . Registered on 22 February 2017.

  8. Cementless total hip arthroplasty with a double chevron subtrochanteric shortening osteotomy in patients with Crowe type-IV hip dysplasia.

    PubMed

    Li, Xigong; Sun, Junying; Lin, Xiangjin; Xu, Sanzhong; Tang, Tiansi

    2013-06-01

    The authors describe a modified double chevron subtrochanteric shortening osteotomy combined with cementless total hip arthroplasty for Crowe type-IV hip dysplasia. Shortening the femur allows to relax the shortened musculature. This operation was performed in 18 patients (22 hips) between January 2000 and February 2006. The mean follow-up period was 5.6 years (range: 3 to 8 years). The mean amount of femoral subtrochanteric shortening was 38 mm (range: 25 to 60 mm). The mean Harris hip score improved from 47 (range: 35 to 65) preoperatively to 88 points (range: 75 to 97) at final follow-up. The Trendelenburg sign was corrected from positive to negative in 12 of 22 hips. No acetabular or femoral components loosened or required revision during the follow-up period. All osteotomy sites healed in 3 to 6 months without complications. Cementless total hip arthroplasty using the modified double chevron subtrochanteric osteotomy provided good short- to midterm results in all 22 Crowe type-IV hip dislocations. Moreover, it restored the anatomic hip center and the limb length, which contributed to correction of the preoperative limp.

  9. Comparison of Downstream Health Care Utilization, Costs, and Long-Term Opioid Use: Physical Therapist Management Versus Opioid Therapy Management After Arthroscopic Hip Surgery.

    PubMed

    Rhon, Daniel I; Snodgrass, Suzanne J; Cleland, Joshua A; Greenlee, Tina A; Sissel, Charles D; Cook, Chad E

    2018-05-01

    Physical therapy and opioid prescriptions are common after hip surgery, but are sometimes delayed or not used. The objective of this study was to compare downstream health care utilization and opioid use following hip surgery for different patterns of physical therapy and prescription opioids. The design of this study was an observational cohort. Health care utilization was abstracted from the Military Health System Data Repository for patients who were 18 to 50 years old and were undergoing arthroscopic hip surgery between 2004 and 2013. Patients were grouped into those receiving an isolated treatment (only opioids or only physical therapy) and those receiving both treatments on the basis of timing (opioid first or physical therapy first). Outcomes included overall health care visits and costs, hip-related visits and costs, additional surgeries, and opioid prescriptions. Of 1870 total patients, 82.7% (n = 1546) received physical therapy only, 71.6% (n = 1339) received prescription opioids, and 1073 (56.1%) received both physical therapy and opioids. Because 24 patients received both opioids and physical therapy on the same day, they were eventually removed the final timing-of-care analysis. Adjusted hip-related mean costs were the same in both groups receiving isolated treatments (${\\$}$11,628 vs ${\\$}$11,579), but the group receiving only physical therapy had significantly lower overall total health care mean costs (${\\$}$18,185 vs ${\\$}$23,842) and fewer patients requiring another hip surgery. For patients receiving both treatments, mean hip-related downstream costs were significantly higher in the group receiving opioids first than in the group receiving physical therapy first (${\\$}$18,806 vs ${\\$}$16,955) and resulted in greater opioid use (7.83 vs 4.14 prescriptions), greater total days' supply of opioids (90.17 vs 44.30 days), and a higher percentage of patients with chronic opioid use (69.5% vs 53.2%). Claims data were limited by the accuracy of coding, and observational data limit inferences of causality. Physical therapy first was associated with lower hip-related downstream costs and lower opioid use than opioids first; physical therapy instead of opioids was associated with less total downstream health care utilization. These results need to be validated in prospective controlled trials.

  10. Long-term outcome of total hip arthroplasty in patients with haemophilia.

    PubMed

    Strauss, A C; Rommelspacher, Y; Nouri, B; Bornemann, R; Wimmer, M D; Oldenburg, J; Pennekamp, P H; Schmolders, J

    2017-01-01

    Besides the target joints (elbow, knee and ankle), the hip is one of the commonly affected joints in haemophilic arthropathy. Hip arthroplasty is the therapy of choice after failure of conservative treatment. There are only limited data on long-term results after primary total hip arthroplasty (THA). The aim of this retrospective study was to analyse clinical outcome and complication rate after total hip replacement in patients with severe haemophilic arthropathy. Forty-three patients with haemophilia (PWH), one patient with von Willebrand disease and one patient with a Factor-VII-deficiency undergoing 49 total hip arthroplasties, were evaluated in a retrospective study. Harris hip score (HHS), range of motion (ROM), pain status (visual analogue scale, VAS) complication rate and patient satisfaction were assessed at a mean follow-up of 11.5 years (range: 3-32). HSS, ROM and VAS improved significantly combined with high patient satisfaction. In total, three (6.1%) periprosthetic infections and five (10.2%) aseptic implant loosenings occurred after THA leading to revision arthroplasty. In two (4.1%) cases, a pseudotumour and one (2.0%) periarticular ossification had to be resected after THA. Total hip replacement in PWH leads to a significant increase of function, reduction of pain and a high satisfaction. Due to the relatively high complication rate (infections and aseptic loosening) compared to patients without haemophilia, an individual assessment of the risk-benefit ratio from surgical and haemostaseological point of view is needed. © 2016 John Wiley & Sons Ltd.

  11. Study of Wearable Knee Assistive Instruments for Walk Rehabilitation

    NASA Astrophysics Data System (ADS)

    Zhu, Yong; Nakamura, Masahiro; Ito, Noritaka; Fujimoto, Hiroshi; Horikuchi, Kenichi; Wakabayashi, Shojiro; Takahashi, Rei; Terada, Hidetsugu; Haro, Hirotaka

    A wearable Knee Assistive Instrument for the walk rehabilitation was newly developed. Especially, this system aimed at supporting the rehabilitation for the post-TKA (Total Knee Arthroplasty) which is a popular surgery for aging people. This system consisted of an assisting mechanism for the knee joint, a hip joint support system and a foot pressure sensor system. The driving system of this robot consisted of a CPU board which generated the walking pattern, a Li-ion battery, DC motors with motor drivers, contact sensors to detect the state of foot and potentiometers to detect the hip joint angle. The control method was proposed to reproduce complex motion of knee joint as much as possible, and to increase hip or knee flexion angle. Especially, this method used the timing that heel left from the floor. This method included that the lower limb was raised to prevent a subject's fall. Also, the prototype of knee assisting system was tested. It was confirmed that the assisting system is useful.

  12. An initial experience with hip resurfacing versus cementless total hip arthroplasty.

    PubMed

    Arndt, Justin Michael; Wera, Glenn D; Goldberg, Victor M

    2013-07-01

    Hip resurfacing is an alternative to total hip arthroplasty. We aimed to compare an experienced hip surgeon's initial clinical results of hip resurfacing with a new cementless total hip arthroplasty (THA). The first 55 consecutive hip resurfacing arthroplasties were compared to 100 consecutive cementless THAs using a cylindrical tapered femoral stem. The learning curve between the two procedures was compared utilizing the incidence of reoperation, complications, Harris Hip Scores (HHS), and implant survivorship. The reoperation rate was significantly higher (p = 0.019) for hip resurfacing (14.5%) versus THA (4%). The overall complication rate between the two groups was not significantly different (p = 0.398). Preoperative HHS were similar between the two groups (p = 0.2). The final mean HHS was similar in both the resurfacing and THA groups (96 vs. 98.3, respectively, p < 0.65). Kaplan-Meier survival analysis with an endpoint of reoperation suggests complications occurred earlier in the resurfacing group versus the THA group (log-rank test, p = 0.007). In comparison to our initial experience with a cementless THA stem, operative complications occur earlier and more often after hip resurfacing during the learning period. The clinical outcomes in both groups however are similar at 5 year follow-up.

  13. Total Hip Arthroplasty Using a Polished Tapered Cemented Stem in Hereditary Multiple Exostosis

    PubMed Central

    Kanda, Akio; Kaneko, Kazuo; Obayashi, Osamu; Mogami, Atsuhiko

    2016-01-01

    A 61-year-old Japanese man underwent right total hip arthroplasty for hereditary multiple exostosis. At first presentation, he had suffered from coxalgia for a long time. On radiographic images, there was a gigantic femoral head, increased shaft angle, and large diameter of the femoral neck. He had also developed coxarthrosis and severe pain of the hip joint. The transformation of the proximal femur bone causes difficulty in setting a cementless total hip prosthesis. Therefore, total hip arthroplasty using a cemented polished tapered stem was performed via a direct lateral approach. Using a cemented polished tapered stem allowed us to deal with the femoral bone transformation and bone substance defectiveness due to exostosis and also minimized the invasiveness of the operation. PMID:27127668

  14. Does hip displacement influence health-related quality of life in children with cerebral palsy?

    PubMed

    Jung, Nikolai H; Pereira, Barbara; Nehring, Ina; Brix, Olga; Bernius, Peter; Schroeder, Sebastian A; Kluger, Gerhard J; Koehler, Tillmann; Beyerlein, Andreas; Weir, Shannon; von Kries, Rüdiger; Narayanan, Unni G; Berweck, Steffen; Mall, Volker

    2014-12-01

    To evaluate the association of hip lateralisation with health-related quality of life (HRQL) in children with cerebral palsy (CP) using the Caregiver Priorities and Child Health Index of Life with Disabilities (CPCHILD(®)) questionnaire. We assessed n = 34 patients (mean age: 10.2 years, SD: 4.7 years; female: n = 16) with bilateral CP and Gross Motor Function Classification System (GMFCS) Level III-V using the CPCHILD(®) questionnaire. Hip lateralisation was measured by Reimer`s migration percentage (MP). There was an association between both, MP and GMFCS with CPCHILD(®) total score. Stratified analyses did not suggest interaction of the association between MP and CPCHILD(®) total score by GMFCS level. After adjustment for GMFCS level, we found a significant linear decrease of CPCHILD(®) total score of -0.188 points by 1% increment in MP. There was an association between MP and HRQL, which could not be explained by the GMFCS level.

  15. Total hip arthroplasty for Crowe IV hip without subtrochanteric shortening osteotomy -a long term follow up study.

    PubMed

    Kawai, Toshiyuki; Tanaka, Chiaki; Kanoe, Hiroshi

    2014-03-10

    Several authors reported encouraging results of total hip arthroplasty (THA) for Crowe IV hips performed using shortening osteotomy. However, few papers have documanted the results of THA for Crowe IV hips without shortening osteotomy. The aim of the present study was to assess the long term-results of cemented THAs for Crowe group IV hips performed without subtrochanteric shortening osteotomy. We have assessed the long term results of 27 cemented total hip arthroplasty (THA) performed without subtrochanteric osteotomy for Crowe group IV hip. All THAs were performed via transtrochanteric approach. After a mean follow-up of 10.6 (6 to 17.9) years, 25 hips (92.6%) had survived without revision surgery and survivorship analysis gave a survival rate of 96.3% at 10 years with any revision surgery as the end point. Although mean limb lengthening was 3.2 (1.0 to 5.1) cm, no hips developed nerve palsy. Complications occurred in four hips, necessitating revision surgery in two. Among the four complications, three involved the greater trochanter, two of which occurred in cases where braided cables had been used to reattach the greater trochanter. Although we encountered four complications, including three trochanteric problems, our findings suggest that THA without subtrochanteric shortening osteotomy can provide satisfactory long-term results in patients with Crowe IV hip.

  16. Cirrhosis is a risk factor for total hip arthroplasty for avascular necrosis.

    PubMed

    Deleuran, Thomas; Overgaard, Søren; Vilstrup, Hendrik; Jepsen, Peter

    2016-06-01

    Background and purpose - There are limited data on risk factors for avascular necrosis of the hip, but cirrhosis has been proposed as a risk factor. We examined the association between cirrhosis and incidence of total hip arthroplasty for avascular necrosis. Methods - We used nationwide healthcare data to identify all Danish residents diagnosed with cirrhosis in 1994-2011, and matched them 1:5 by age and sex to non-cirrhotic reference individuals from the general population. We excluded people with a previous total hip arthroplasty, a previous hip fracture, or a previous diagnosis of avascular necrosis. We used stratified Cox regression to estimate the hazard ratio (HR) for cirrhosis patients relative to reference individuals, adjusting for potential confounders. We used the cumulative incidence function to compute 5-year risks. Results - We included 25,421 cirrhosis patients and 114,052 reference individuals. Their median age was 57 years, and 65% were men. 45 cirrhosis patients and 44 reference individuals underwent total hip arthroplasty for avascular necrosis. Cirrhosis patients' HR for a total hip arthroplasty for avascular necrosis was 10 (95% CI: 6-17), yet their 5-year risk of avascular necrosis was only 0.2%. For the reference individuals, the 5-year risk was 0.02%. Interpretation - Cirrhosis is a strong risk factor for avascular necrosis of the hip, but it is rare even in cirrhosis patients.

  17. Cirrhosis is a risk factor for total hip arthroplasty for avascular necrosis

    PubMed Central

    Deleuran, Thomas; Overgaard, Søren; Vilstrup, Hendrik; Jepsen, Peter

    2016-01-01

    Background and purpose There are limited data on risk factors for avascular necrosis of the hip, but cirrhosis has been proposed as a risk factor. We examined the association between cirrhosis and incidence of total hip arthroplasty for avascular necrosis. Methods We used nationwide healthcare data to identify all Danish residents diagnosed with cirrhosis in 1994–2011, and matched them 1:5 by age and sex to non-cirrhotic reference individuals from the general population. We excluded people with a previous total hip arthroplasty, a previous hip fracture, or a previous diagnosis of avascular necrosis. We used stratified Cox regression to estimate the hazard ratio (HR) for cirrhosis patients relative to reference individuals, adjusting for potential confounders. We used the cumulative incidence function to compute 5-year risks. Results We included 25,421 cirrhosis patients and 114,052 reference individuals. Their median age was 57 years, and 65% were men. 45 cirrhosis patients and 44 reference individuals underwent total hip arthroplasty for avascular necrosis. Cirrhosis patients’ HR for a total hip arthroplasty for avascular necrosis was 10 (95% CI: 6–17), yet their 5-year risk of avascular necrosis was only 0.2%. For the reference individuals, the 5-year risk was 0.02%. Interpretation Cirrhosis is a strong risk factor for avascular necrosis of the hip, but it is rare even in cirrhosis patients. PMID:26900635

  18. Friction measurement in a hip wear simulator.

    PubMed

    Saikko, Vesa

    2016-05-01

    A torque measurement system was added to a widely used hip wear simulator, the biaxial rocking motion device. With the rotary transducer, the frictional torque about the drive axis of the biaxial rocking motion mechanism was measured. The principle of measuring the torque about the vertical axis above the prosthetic joint, used earlier in commercial biaxial rocking motion simulators, was shown to sense only a minor part of the total frictional torque. With the present method, the total frictional torque of the prosthetic hip was measured. This was shown to consist of the torques about the vertical axis above the joint and about the leaning axis. Femoral heads made from different materials were run against conventional and crosslinked polyethylene acetabular cups in serum lubrication. Regarding the femoral head material and the type of polyethylene, there were no categorical differences in frictional torque with the exception of zirconia heads, with which the lowest values were obtained. Diamond-like carbon coating of the CoCr femoral head did not reduce friction. The friction factor was found to always decrease with increasing load. High wear could increase the frictional torque by 75%. With the present system, friction can be continuously recorded during long wear tests, so the effect of wear on friction with different prosthetic hips can be evaluated. © IMechE 2016.

  19. Joint registries as continuous surveillance systems: the experience of the Catalan Arthroplasty Register (RACat).

    PubMed

    Allepuz, Alejandro; Martínez, Olga; Tebé, Cristian; Nardi, Joan; Portabella, Frederic; Espallargues, Mireia

    2014-03-01

    The aim was to present results on prosthesis performance in Catalonia for the period 2005-2010. All publicly funded hospitals submit in an electronic format data on hip and knee arthroplasties: patients' insurance identification number, hospital, joint (hip/knee), type of arthroplasty (primary/revision), side (right/left), date of surgery and prosthesis (manufacturer name and catalogue number). A standard survival analysis based on Kaplan-Meier estimation was carried out. Fifty-two hospitals have sent information to the RACat which has data on 36,951 knee and 26,477 hip arthroplasties. Cumulative prostheses revision risks at 3 years were 3.3% (95% CI: 3.1-3.6) for knee, 2.9% (95% CI: 2.5-3.3) for total hip and 2.5% (95% CI: 2.0-3.1) for partial hip. When compared to other registries a higher risk of revision was observed. © 2013.

  20. Hip Abductor Strengthening Improves Physical Function Following Total Knee Replacement: One-Year Follow-Up of a Randomized Pilot Study.

    PubMed

    Harikesavan, Karvannan; Chakravarty, Raj D; Maiya, Arun G; Hegde, Sanjay P; Y Shivanna, Shivakumar

    2017-01-01

    Total knee replacement (TKR) is the commonest surgical procedure for patients with severe pain and impaired physical function following end stage knee osteoarthritis. The hip abductors are well renowned in stabilization of the trunk and hip during walking, maintaining the lower limb position, and transferring the forces from the lower limbs to the pelvis. To assess the efficacy of hip abductor strengthening exercise on functional outcome using performance based outcome measures following total knee replacement. An observer blinded randomized pilot trial design was conducted at Manipal hospital, Bangalore, India. Participants designated for elective TKR were randomized to experimental group hip abductor strengthening along with standard rehabilitation (n=10) or control group standard rehabilitation alone (n=10). Participants followed for one year to assess physical function using performance based outcomes, such as timed up and go test, single leg stance test, six minute walk test, knee extensor strength and hip abductor strength. Eighteen participants with a mean age of 63.1 ± 5.5 years (8 Males and 10 Females) completed the study. Improvement in hip abduction strength, single leg stand test was superior in hip abductor strengthening group at 3 months and 1 year when compared to standard rehabilitation alone. Hip abductor strengthening showed superior improvements in single leg stance test and six minute walk test. Hip abductor strengthening exercises has the potential to improve physical function following total knee replacement.

  1. Hip Abductor Strengthening Improves Physical Function Following Total Knee Replacement: One-Year Follow-Up of a Randomized Pilot Study

    PubMed Central

    Harikesavan, Karvannan; Chakravarty, Raj D.; Maiya, Arun G; Hegde, Sanjay P.; Y. Shivanna, Shivakumar

    2017-01-01

    Background: Total knee replacement (TKR) is the commonest surgical procedure for patients with severe pain and impaired physical function following end stage knee osteoarthritis. The hip abductors are well renowned in stabilization of the trunk and hip during walking, maintaining the lower limb position, and transferring the forces from the lower limbs to the pelvis. Objective: To assess the efficacy of hip abductor strengthening exercise on functional outcome using performance based outcome measures following total knee replacement. Methods: An observer blinded randomized pilot trial design was conducted at Manipal hospital, Bangalore, India. Participants designated for elective TKR were randomized to experimental group hip abductor strengthening along with standard rehabilitation (n=10) or control group standard rehabilitation alone (n=10). Participants followed for one year to assess physical function using performance based outcomes, such as timed up and go test, single leg stance test, six minute walk test, knee extensor strength and hip abductor strength. Result: Eighteen participants with a mean age of 63.1 ± 5.5 years (8 Males and 10 Females) completed the study. Improvement in hip abduction strength, single leg stand test was superior in hip abductor strengthening group at 3 months and 1 year when compared to standard rehabilitation alone. Conclusion: Hip abductor strengthening showed superior improvements in single leg stance test and six minute walk test. Hip abductor strengthening exercises has the potential to improve physical function following total knee replacement. PMID:28567148

  2. The operation of the century: total hip replacement.

    PubMed

    Learmonth, Ian D; Young, Claire; Rorabeck, Cecil

    2007-10-27

    In the 1960s, total hip replacement revolutionised management of elderly patients crippled with arthritis, with very good long-term results. Today, young patients present for hip-replacement surgery hoping to restore their quality of life, which typically includes physically demanding activities. Advances in bioengineering technology have driven development of hip prostheses. Both cemented and uncemented hips can provide durable fixation. Better materials and design have allowed use of large-bore bearings, which provide an increased range of motion with enhanced stability and very low wear. Minimally invasive surgery limits soft-tissue damage and facilitates accelerated discharge and rehabilitation. Short-term objectives must not compromise long-term performance. Computer-assisted surgery will contribute to reproducible and accurate placement of implants. Universal economic constraints in healthcare services dictate that further developments in total hip replacement will be governed by their cost-effectiveness.

  3. Dynamic behavior of tripolar hip endoprostheses under physiological conditions and their effect on stability.

    PubMed

    Fabry, Christian; Kaehler, Michael; Herrmann, Sven; Woernle, Christoph; Bader, Rainer

    2014-01-01

    Tripolar systems have been implanted to reduce the risk of recurrent dislocation. However, there is little known about the dynamic behavior of tripolar hip endoprostheses under daily life conditions and achieved joint stability. Hence, the objective of this biomechanical study was to examine the in vivo dynamics and dislocation behavior of two types of tripolar systems compared to a standard total hip replacement (THR) with the same outer head diameter. Several load cases of daily life activities were applied to an eccentric and a concentric tripolar system by an industrial robot. During testing, the motion of the intermediate component was measured using a stereo camera system. Additionally, their behavior under different dislocation scenarios was investigated in comparison to a standard THR. For the eccentric tripolar system, the intermediate component demonstrated the shifting into moderate valgus-positions, regardless of the type of movement. This implant showed the highest resisting torque against dislocation in combination with a large range of motion. In contrast, the concentric tripolar system tended to remain in varus-positions and was primarily moved after stem contact. According to the results, eccentric tripolar systems can work well under in vivo conditions and increase hip joint stability in comparison to standard THRs. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  4. Long-term result of cementless femoral stem in avascular necrosis of the hip.

    PubMed

    Cheung, Kin W; Chiu, Kwok H; Chung, Kwong Y

    2015-01-01

    Avascular necrosis (AVN) of the hip may have extensive involvement of the proximal femur which may affect boney ingrowth into cementless femoral stems. From 1994 to 2004, 182 total hip arthroplasties (in 144 patients, 117 AVN hips and 65 non-AVN hips) were performed using hydroxyapatite coated femoral stems. All patients were followed up prospectively. Mean age was 51 years and mean follow-up 14.7 years (range 9.7-19.1 years). Four stems were revised because of aseptic loosening, 3 in AVN group and 1 in non-AVN group. The overall mechanical failure rate was 2.2%, the mechanical failure rate in AVN and non-AVN group was 2.6% and 1.5% respectively (p = 1). The 19.1 year survival using revision for aseptic loosening as an endpoint for AVN and non-AVN patients were 97.1% and 96.2% respectively (p = 0.654). Stable boney ingrowth was present in 99.5% hips. This study represents 1 of the largest series reporting the long-term follow-up of the use of cementless femoral stems in treating AVN of the hip. We report excellent long-term survival of cementless total hip arthroplasty used in managing AVN of the hip and is comparable to that seen in non-AVN total hip arthroplasty.

  5. The Transverse Acetabular Ligament as an Intraoperative Guide to Cup Abduction.

    PubMed

    Hiddema, Willem B; van der Merwe, Johan F; van der Merwe, Werner

    2016-07-01

    The success of a total hip arthroplasty relies on optimal acetabular cup placement to ensure mating of the femoral head and acetabular cup throughout all positions of the hip joint. Poor cup placement is associated with dislocation, impingement, microseparation, component loosening, and accelerated wear due to rim loading. This study examined a novel method of using the transverse acetabular ligament (TAL) to guide cup inclination during primary total hip arthroplasty. A descriptive study using 16 hips from 9 cadavers. A computer navigation system measured inclination and version of the acetabular component in 3 positions with the lower edge of cup: (1) flush with, (2) 5 mm proximal to, and (3) 5 mm distal to free border of the TAL. The median inclination angles were 44° in position (1), 30° in position (2), and 64° in position (3). The median anteversion angle for all positions was 19°. Cup inclination was acceptable when the lower edge of the cup was flush or within 5 mm proximal to the TAL. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Ultrasound in detection of developmental hip dysplasia in premature born children.

    PubMed

    Misanovic, Verica; Jonuzi, Fedzat; Maksic-Kovacevic, Hajra; Rahmanovic, Selma

    2015-04-01

    Developmental hip dysplasia represents the most common deformation of locomotor system in children. Developmental modulation of the hip is expressed during first year of life which is important for early diagnosis and treatment. Therefore, in the practice, it is very important to set a diagnosis early with application of simple and convenient methods (ultrasound) in order to achieve fast and efficient therapeutical effect and avoid permanent disability. The aim of this paper is to point out the increase of prematurely born infants and their survival thanks to the development of Unit for Intensive Neonatal Care at the Pediatric Clinics in Sarajevo. Clinical investigation included 150 infants (77 girls and 73 boys) in whom the developmental hip dysplasia was diagnosed with clinical exam, ultrasound exam and x-ray of the hips. The exams were done in period of January 2012 to August 2014. Two groups of patients were formed. The first one consisted of premature infants, total number of 75 (34 girls and 41 boys), with developmental hip dysplasia that was diagnosed at the first exam at the Ultrasound unit of the Pediatric clinics and at the Intensive Neonatal Care Unit of the Pediatric Clinics in Sarajevo. Second (control) group consistsed of patients-on term infants who had diagnosed one of developmental hip dysplasia, total of 75 (43 girls and 32 boys) during first exam in the Ultrasound unit of the Pediatric clinics in Sarajevo. The frequency of premature birth is between 5 and 10% of all labors and demonstrates increasing trend. We suggest ultrasound examination of hips in each newborn, term or premature, at the age of 6 weeks after birth.

  7. Outcomes of dual-mobility acetabular cup for instability in primary and revision total hip arthroplasty.

    PubMed

    Mohammed, Riazuddin; Hayward, Keith; Mulay, Sanjay; Bindi, Frank; Wallace, Murray

    2015-03-01

    The concept of a dual-mobility hip socket involves the standard femoral head component encased in a larger polyethylene liner, which in turn articulates inside a metal shell implanted in the native acetabulum. The aim of this study was to assess outcomes from using a Serf Novae(®) Dual Mobility Acetabular cup (Orthodynamics Ltd, Gloucestershire, UK) to address the problem of instability in primary and revision total hip arthroplasty (THA). A retrospective review was carried out of all hip arthroplasties performed in a District General Hospital utilising the dual-mobility socket from January 2007 to December 2012. Clinical and radiological outcomes were analysed for 44 hips in 41 patients, comprising 20 primary and 24 revision THA. The average age of the study group was 70.8 years (range 56-84 years) for primary and 76.4 years (range 56-89 years) for revision arthroplasty. Among the primary THA, always performed for hip osteoarthritis or in presence of osteoarthritic changes, the reasons to choose a dual mobility cup were central nervous system problems such as Parkinson's disease, stroke, dementia (10), hip fracture (5), failed hip fracture fixation (2), severe fixed hip deformity (2) and diffuse peripheral neuropathy (1). The indications for revisions were recurrent dislocation (17), aseptic loosening with abductor deficiency (4), failed hemiarthroplasty with abductor deficiency (2) and neglected dislocation (1). At a mean follow-up of 22 months (range 6-63 months), none of the hips had any dislocation, instability or infection and no further surgical intervention was required. Radiological assessment showed that one uncemented socket in a revision arthroplasty performed for recurrent dislocation had changed position, but was stable in the new position. The patient did not have complications from this and did not need any surgical intervention. Even though postoperative hip stability depends on several factors other than design-related ones, our study shows promising early results for reducing the risk of instability in this challenging group of patients undergoing primary and revision hip arthroplasty. IV.

  8. Primary total hip arthroplasty versus hemiarthroplasty for displaced intracapsular hip fractures in older patients: systematic review.

    PubMed

    Hopley, Colin; Stengel, Dirk; Ekkernkamp, Axel; Wich, Michael

    2010-06-11

    To determine whether total hip arthroplasty is associated with lower reoperation rates, mortality, and complications, and better function and quality of life than hemiarthroplasty for displaced fractures of the femoral neck in older patients. Systematic review and meta-analysis of randomised trials, quasirandomised trials, and cohort studies. Medline, Embase, Cochrane register of controlled trials, publishers' databases, and manual search of bibliographies. Randomised controlled trials, quasirandomised trials, and cohort studies (retrospective and prospective) comparing hemiarthroplasty with total hip arthroplasty for treating displaced femoral neck fractures in patients aged more than 60 years. Relative risks, risk differences, and mean differences from each trial, aggregated using random effects models. Analyses were stratified for experimental and non-experimental designs, and two way sensitivity analyses and tests for interaction were done to assess the influence of various criteria of methodological quality on pooled estimates. 3821 references were identified. Of the 202 full papers inspected, 15 were included (four randomised controlled trials, three quasirandomised trials, and eight retrospective cohort studies, totalling 1890 patients). Meta-analysis of 14 studies showed a lower risk of reoperation after total hip arthroplasty compared with hemiarthroplasty (relative risk 0.57, 95% confidence interval 0.34 to 0.96, risk difference 4.4%, 95% confidence interval 0.2% to 8.5%), although this effect was mainly driven by investigations without concealed treatment allocation. Total hip arthroplasty consistently showed better ratings in the Harris hip score (three studies, 246 patients, weighted mean difference 5.4, 95% confidence interval 2.7 to 8.2) after follow-up periods of 12 to 48 months. The standardised mean difference of different scores from five studies was 0.42 (95% confidence interval 0.24 to 0.61), indicating a medium functional advantage of total hip arthroplasty over hemiarthroplasty. Total hip arthroplasty was associated with a slightly higher risk of dislocation (relative risk 1.48, 95% confidence interval 0.89 to 2.46) and general complications (1.14, 0.87 to 1.48). Single stage total hip arthroplasty may lead to lower reoperation rates and better functional outcomes compared with hemiarthroplasty in older patients with displaced femoral neck fractures. However, heterogeneity across the available trials and distinct subgroup effects preclude definitive statements and require further research in this area.

  9. Long-term clinical and radiographic outcome of the PPF system in ceramic-on-polyethylene hip bearings.

    PubMed

    Legenstein, R; Huber, W; Ungersboeck, A; Boesch, P

    2006-01-01

    From 1990 to 1991 we implanted 176 non-cemented proximal press-fit (PPF) total hip arthroplasties (THA) with ceramic-on-polyethylene articulation in 170 patients. Of these, 119 patients (122 THA) were followed from 104 to 129 months. Four cups have been revised for aseptic loosening, but revealed no radiolucencies of the stem. Two infections and two dislocations occurred. The median postoperative Harris hip score was 91. Ninety-eight per cent of the patients were satisfied with the outcome, 83% were free of pain and 67% walked without a limp. Serial radiographs showed stable fixation with bone ongrowth in nearly all arthroplasties except for four cups. Stem radiolucencies were first seen within 12 months, but were of no clinical relevance. Proximal periprosthetic bone resorption of the stem was seen in 18%. Radiolucencies occurred because of polyethylene debris-induced granulomas. The PPF system yields satisfactory long-term results in patients with primary and secondary hip osteoarthritis and dysplasia.

  10. Pain conditions ranked by healthcare costs for members of a national health plan.

    PubMed

    Pasquale, Margaret K; Dufour, Robert; Schaaf, David; Reiners, Andrew T; Mardekian, Jack; Joshi, Ashish V; Patel, Nick C

    2014-02-01

    Healthcare resource utilization (HCRU) and associated costs specific to pain are a growing concern, as increasing dollar amounts are spent on pain-related conditions. Understanding which pain conditions drive the highest utilization and cost burden to the healthcare system would enable providers and payers to better target conditions to manage pain adequately and efficiently. The current study focused on 36 noncancer chronic and 14 noncancer acute pain conditions and measured the HCRU and costs per member over 365 days. These conditions were ranked by per-member costs and total adjusted healthcare costs to determine the most expensive conditions to a national health plan. The top 5 conditions for the commercial line of business were back pain, osteoarthritis (OA), childbirth, injuries, and non-hip, non-spine fractures (adjusted annual total costs for the commercial members were $119 million, $98 million, $69 million, $61 million, and $48 million, respectively). The top 5 conditions for Medicare members were OA, back pain, hip fractures, injuries, and non-hip, non-spine fractures (adjusted annual costs for the Medicare members were $327 million, $218 million, $117 million, $82 million, and $67 million, respectively). The conditions ranked highest for both per-member and total healthcare costs were hip fractures, childbirth, and non-hip, non-spine fractures. Among these, hip fractures in the Medicare member population had the highest mean cost per member (adjusted per-member cost was $21,058). Further examination specific to how pain is managed in these high-cost conditions will enable providers and payers to develop strategies to improve patient outcomes through appropriate pain management. © 2013 Humana Inc. and Pfizer Inc. Pain Practice © 2013 World Institute of Pain.

  11. Accuracy of screening compression ultrasonography and clinical examination for the diagnosis of deep vein thrombosis after total hip or knee arthroplasty

    PubMed Central

    Robinson, K. Sue; Anderson, David R.; Gross, Michael; Petrie, David; Leighton, Ross; Stanish, William; Alexander, David; Mitchell, Michael; Mason, William; Flemming, Bruce; Fairhurst-Vaughan, Marlene; Gent, Michael

    1998-01-01

    Objective To determine whether compression ultrasonography or clinical examination should be considered as screening tests for the diagnosis of deep vein thrombosis (DVT) after total hip or knee arthroplasty in patients receiving warfarin prophylaxis postoperatively. Design A prospective cohort study. Setting A single tertiary care orthopedic centre. Patients One hundred and eleven patients who underwent elective total hip or knee arthroplasty were enrolled. Postoperatively the warfarin dose was adjusted daily to maintain the international normalized ratio between 1.8 and 2.5. Eighty-six patients successfully completed the study protocol. Intervention Before they were discharged from hospital, patients were assessed for DVT by clinical examination, bilateral compression ultrasonography of the proximal venous system and bilateral contrast venography. Results DVT was found in 29 patients (34%; 95% confidence interval [CI] 24% to 45%), and 6 patients (7%; 95% CI 3% to 15%) had proximal DVT. DVT developed in 18 (40%) of 45 patients who underwent total knee arthroplasty and in 11 (27%) of 41 patients who underwent total hip arthroplasty. The sensitivity of compression ultrasonography for the diagnosis of proximal DVT was 83% (95% CI 36% to 99%) and the specificity was 98% (95% CI 91% to 99%). The positive predictive value of compression ultrasonography was 71%. In contrast, clinical examination for DVT had a sensitivity of 11% (95% CI 2% to 28%) and a positive predictive value of 25%. Conclusions DVT is a common complication after total hip or knee arthroplasty. Compression ultrasonography appears to be a relatively accurate noninvasive test for diagnosing postoperative proximal DVT. In contrast, clinical examination is a very insensitive test. Whether routine use of screening compression ultrasonography will reduce the morbidity of venous thromboembolism after joint arthroplasty requires confirmation in a prospective trial involving long-term follow-up of patients. PMID:9793503

  12. Predictors for Long-Term Hip Survivorship Following Acetabular Fracture Surgery: Importance of Gap Compared with Step Displacement.

    PubMed

    Verbeek, Diederik O; van der List, Jelle P; Tissue, Camden M; Helfet, David L

    2018-06-06

    Historically, the greatest residual (gap or step) displacement is used to predict clinical outcome following acetabular fracture surgery. Gap and step displacement may, however, impact the outcome to different degrees. We assessed the individual relationship between gap or step displacement and hip survivorship and determined their independent association with conversion to total hip arthroplasty. Patients who had acetabular fracture fixation (from 1992 through 2014), follow-up of ≥2 years (or early conversion to total hip arthroplasty), and postoperative computed tomography (CT) scans were included. Of 227 patients, 55 (24.2%) had conversion to total hip arthroplasty at a mean follow-up (and standard deviation) of 8.7 ± 5.6 years. Residual gap and step displacement were measured using a standardized CT-based method, and assessors were blinded to the outcome. Kaplan-Meier survivorship curves for the hips were plotted and compared (log-rank test) using critical cutoff values for gap and step displacement. These values were identified using receiver operating characteristic curves. Multivariate analysis was performed to identify independent variables associated with conversion to total hip arthroplasty. Subgroup analysis was performed in younger patients (<50 years old). The critical CT cutoff value for total hip arthroplasty conversion was 5 mm for gap and 1 mm for step displacement. Hip survivorship at 10 years was 82.0% for patients with a gap of <5 mm compared with 56.5% for a gap of ≥5 mm (p < 0.001) and 80.0% for a step of <1.0 mm versus 65.5% for a step of ≥1.0 mm (p = 0.012). A gap of ≥5 mm (hazard ratio [HR], 2.3; p = 0.012) and an age of ≥50 years (HR, 4.2; p < 0.001) were independently associated with conversion to total hip arthroplasty in all patients. In the subgroup of younger patients, only a step of ≥1 mm (HR, 6.4; p = 0.017) was an independent factor for conversion to total hip arthroplasty. Residual gap and step displacement as measured on CT scans are both related to long-term hip survivorship, but step displacement (1 mm) is tolerated less than gap displacement (5 mm). Of the 2 types of displacement, only a large gap displacement (≥5 mm) was independently associated with conversion to total hip arthroplasty. In younger patients who had less articular impaction with smaller residual gaps, only step displacement (≥1 mm) appeared to be associated with this outcome. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  13. The efficacy of modified direct lateral versus posterior approach on gait function and hip muscle strength after primary total hip arthroplasty at 12months follow-up. An explorative randomised controlled trial.

    PubMed

    Rosenlund, Signe; Broeng, Leif; Overgaard, Søren; Jensen, Carsten; Holsgaard-Larsen, Anders

    2016-11-01

    The lateral and the posterior approach are the most commonly used procedures for total hip arthroplasty. Due to the detachment of the hip abductors, lateral approach is claimed to cause reduced hip muscle strength and altered gait pattern. However, this has not been investigated in a randomised controlled trial. The aim was to compare the efficacy of total hip arthroplasty performed by lateral or posterior approach on gait function and hip muscle strength up to 12months post-operatively. We hypothesised that posterior approach would be superior to lateral approach. Forty-seven patients with primary hip osteoarthritis were randomised to total hip arthroplasty with either posterior or lateral approach and evaluated pre-operatively, 3 and 12months post-operatively using 3-dimensional gait analyses as objective measures of gait function, including Gait Deviation Index, temporo-spatial parameters and range of motion. Isometric maximal hip muscle strength in abduction, flexion and extension was also tested. Post-operatively, no between-group difference in gait function was observed. However, both hip abductor and flexor muscle strength improved more in the posterior approach group: -0.20(Nm/kg)[95%CI:-0.4 to 0.0] and -0.20(Nm/kg)[95%CI:-0.4 to 0.0], respectively. Contrary to our first hypothesis, the overall gait function in the posterior approach group did not improve more than in the lateral approach group. However, in agreement with our second hypothesis, patients in the posterior approach group improved more in hip abductor and flexor muscle strength at 12months. Further investigation of the effect of reduced maximal hip muscle strength on functional capacity is needed. ClinicalTrials.gov. No.: NCT01616667. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Systematic analysis of the quality of the scientific evidence and conflicts of interest in osteoarthritis of the hip and knee practice guidelines.

    PubMed

    Feuerstein, Joseph D; Pelsis, Jonathan R; Lloyd, Samuel; Cheifetz, Adam S; Stone, Kevin R

    2016-02-01

    To determine the validity of the hip and knee osteoarthritis guidelines. A systematic search of PubMed using a combination of Mesh and text terms with limitations to guidelines was performed to identify hip and knee osteoarthritis guidelines. The study was performed from April 17, 2014 to October 1, 2014. Guidelines were reviewed for graded levels of evidence, methods used to grade the evidence, and disclosures of conflicts of interest. Additionally, guidelines were also assessed for key quality measures using the AGREE II system for assessing the quality of guidelines. A total of 13 guidelines relevant to the diagnosis and/or treatment of hip/knee osteoarthritis was identified. The 180 recommendations reviewed were supported by 231 pieces of evidence. In total, 35% (n = 80; range: 0-26) were supported by level A evidence, 15% (n = 35; range: 0-10) were by level B, and 50% (n = 116; range: 0-62) were by level C. Median age of the guidelines was 4 years (±4.8; range: 0-16) with no comments on planned updates. In total, 31% of the guidelines included patients in the development process. Only one guideline incorporated cost consideration, and only 15% of the guidelines addressed the surgical management of osteoarthritis. Additionally, 46% of guidelines did not comment on conflicts of interest (COI). When present, there was an average 29.8 COI. Notably, 82% of the COI were monetary support/consulting. In total, 50% of the hip/knee osteoarthritis guideline recommendations are based on lower quality evidence. Nearly half the guidelines fail to disclose relevant COI and when disclosed, multiple potential COI are present. Future hip/knee osteoarthritis guideline development committees should strive to improve the transparency and quality of evidence used to formulate practice guidelines. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Cemented total hip replacement cable debris and acetabular construct durability.

    PubMed

    Altenburg, Aaron J; Callaghan, John J; Yehyawi, Tameem M; Pedersen, Douglas R; Liu, Steve S; Leinen, Jessica A; Dahl, Kevin A; Goetz, Devon D; Brown, Thomas D; Johnston, Richard C

    2009-07-01

    Third-body wear can adversely affect the outcome of total hip arthroplasty by causing increased polyethylene wear, osteolysis, and component loosening. We hypothesized that there would be greater generation and migration of metal debris to the bearing surfaces in hips in which cobalt-chromium cables were used to reattach the osteotomized greater trochanter when compared with hips in which stainless steel wires were used. Between June 1981 and December 1983, 196 consecutive total hip arthroplasties were performed with use of an Iowa stem and a titanium-backed cemented acetabular component, with cobalt-chromium cable trochanteric reattachment. After nineteen to twenty years of follow-up, the patients were evaluated with regard to the depth of head penetration into the polyethylene (as a surrogate for wear), osteolysis, loosening, and the need for revision. The results were compared with those for a series of 304 total hip arthroplasties that were performed by the same surgeon from January 1984 to December 1985 with use of the same components and the same surgical technique, but with stainless steel wire trochanteric reattachment. The two groups had a comparable nineteen to twenty-year follow-up. All living patients (fifty-nine hips in the cable group and ninety-two hips in the wire group) had minimum ten-year follow-up radiographs. The polyethylene wear rate was 0.101 mm/yr for the cable group and 0.082 mm/yr for the wire group (p = 0.039). For the living patients, the rate of revision of the acetabular component because of aseptic loosening was 37.3% (twenty-two hips) for the cable group and 20.7% (nineteen hips) for the wire group (p = 0.025). The rate of acetabular osteolysis was 44% (twenty-six hips) for the cable group and 26% (twenty-four hips) for the wire group (p = 0.022). Kaplan-Meier analysis with revision of the acetabular component because of aseptic loosening as the end point demonstrated survival rates of 73.7% +/- 9% and 83% +/- 7% for the cable and wire groups, respectively, at twenty years (p = 0.03). Because cable trochanteric attachment led to significantly greater polyethylene wear, osteolysis, acetabular loosening, and acetabular revision, presumably due to third-body metallic debris generation in this cemented total hip replacement construct, surgeons should be aware of the deleterious effects of third-body debris and avoid the use of potential debris generators in the total hip arthroplasty construct. If cable is used and fretting is recognized, especially with intra-articular migration of metallic material or nonunion of the greater trochanter, consideration should be given to cable removal.

  16. Total hip replacement for hip fracture: Surgical techniques and concepts.

    PubMed

    Coomber, Ross; Porteous, Matthew; Hubble, Matthew J W; Parker, Martyn J

    2016-10-01

    When treating a hip fracture with a total hip replacement (THR) the surgical technique may differ in a number of aspects in comparison to elective arthroplasty. The hip fracture patient is more likely to have poor bone stock secondary to osteoporosis, be older, have a greater number of co-morbidities, and have had limited peri-operative work-up. These factors lead to a higher risk of complications, morbidity and perioperative mortality. Consideration should be made to performing the THR in a laminar flow theatre, by a surgeon experienced in total hip arthroplasty, using an anterolateral approach, cementing the implant in place, using a large head size and with repair of the joint capsule. Combined Ortho-geriatric care is recommended with similar post-operative rehabilitation to elective THR patients but with less expectation of short length of stay and consideration for fracture prevention measures. Copyright © 2016. Published by Elsevier Ltd.

  17. Estimation of wear in total hip replacement using a ten station hip simulator.

    PubMed

    Brummitt, K; Hardaker, C S

    1996-01-01

    The results of hip simulator tests on a total of 16 total hip joints, all of them 22.25 mm Charnley designs, are presented. Wear at up to 6.75 million cycles was assessed by using a coordinate measuring machine. The results gave good agreement with clinical estimates of wear rate on the same design of joint replacement from a number of sources. Good agreement was also obtained when comparison was made with the published results from more sophisticated simulators. The major source of variation in the results was found to occur in the first million cycles where creep predominates. The results of this study support the use of this type of simplified simulator for estimating wear in a total hip prosthesis. The capability to test a significant number of joints simultaneously may make this mechanism preferable to more complex machines in many cases.

  18. A Water Rehabilitation Program in Patients with Hip Osteoarthritis Before and After Total Hip Replacement.

    PubMed

    Łyp, Marek; Kaczor, Ryszard; Cabak, Anna; Tederko, Piotr; Włostowska, Ewa; Stanisławska, Iwona; Szypuła, Jan; Tomaszewski, Wiesław

    2016-07-25

    BACKGROUND Pain associated with coxarthrosis, typically occurring in middle-aged and elderly patients, very commonly causes considerable limitation of motor fitness and dependence on pharmacotherapy. This article provides an assessment of a rehabilitation program with tailored water exercises in patients with osteoarthritis before and after total hip replacement. MATERIAL AND METHODS A total of 192 patients (the mean age 61.03±10.89) suffering from hip osteoarthritis (OA) were evaluated before and after total hip replacement (THR). The clinical study covered measurements of hip active ranges of motion (HAROM) and the forces generated by pelvis stabilizer muscles. Pain intensity was assessed according to analogue-visual scale of pain (VAS) and according to the Modified Laitinen Questionnaire. The patients were divided into 6 groups (4 treatment and 2 control). We compared 2 rehabilitation programs using kinesitherapy and low-frequency magnetic field. One of them also had specially designed exercises in the water. Statistical analysis was carried out at the significance level α=0.05. This was a cross-sectional study. RESULTS A positive effect of water exercises on a number of parameters was found in patients with OA both before and after total hip replacement surgery. We noted a significant reduction of pain (p<0.001), increased ranges of motion and muscle strength, and reduced use of medicines (NASAIDs) (p<0.001). A correlation was found between the degree of degenerative deforming lesions and the effects of the treatment process (p<0.01). CONCLUSIONS 1. The rehabilitation program including water exercises most significantly reduced pain in patients with OA before and after total hip replacement surgery. 2. Inclusion of water exercises in a rehabilitation program can reduce the use of medicines in patient with OA and after THR.

  19. Experimental validation of finite element modelling of a modular metal-on-polyethylene total hip replacement.

    PubMed

    Hua, Xijin; Wang, Ling; Al-Hajjar, Mazen; Jin, Zhongmin; Wilcox, Ruth K; Fisher, John

    2014-07-01

    Finite element models are becoming increasingly useful tools to conduct parametric analysis, design optimisation and pre-clinical testing for hip joint replacements. However, the verification of the finite element model is critically important. The purposes of this study were to develop a three-dimensional anatomic finite element model for a modular metal-on-polyethylene total hip replacement for predicting its contact mechanics and to conduct experimental validation for a simple finite element model which was simplified from the anatomic finite element model. An anatomic modular metal-on-polyethylene total hip replacement model (anatomic model) was first developed and then simplified with reasonable accuracy to a simple modular total hip replacement model (simplified model) for validation. The contact areas on the articulating surface of three polyethylene liners of modular metal-on-polyethylene total hip replacement bearings with different clearances were measured experimentally in the Leeds ProSim hip joint simulator under a series of loading conditions and different cup inclination angles. The contact areas predicted from the simplified model were then compared with that measured experimentally under the same conditions. The results showed that the simplification made for the anatomic model did not change the predictions of contact mechanics of the modular metal-on-polyethylene total hip replacement substantially (less than 12% for contact stresses and contact areas). Good agreements of contact areas between the finite element predictions from the simplified model and experimental measurements were obtained, with maximum difference of 14% across all conditions considered. This indicated that the simplification and assumptions made in the anatomic model were reasonable and the finite element predictions from the simplified model were valid. © IMechE 2014.

  20. Surgical anesthesia with a combination of T12 paravertebral block and lumbar plexus, sacral plexus block for hip replacement in ankylosing spondylitis: CARE-compliant 4 case reports.

    PubMed

    Ke, Xijian; Li, Ji; Liu, Yong; Wu, Xi; Mei, Wei

    2017-06-26

    Anesthesia management for patients with severe ankylosing spondylitis scheduled for total hip arthroplasty is challenging due to a potential difficult airway and difficult neuraxial block. We report 4 cases with ankylosing spondylitis successfully managed with a combination of lumbar plexus, sacral plexus and T12 paravertebral block. Four patients were scheduled for total hip arthroplasty. All of them were diagnosed as severe ankylosing spondylitis with rigidity and immobilization of cervical and lumbar spine and hip joints. A combination of T12 paravertebral block, lumbar plexus and sacral plexus block was successfully used for the surgery without any additional intravenous anesthetic or local anesthetics infiltration to the incision, and none of the patients complained of discomfort during the operations. The combination of T12 paravertebral block, lumbar plexus and sacral plexus block, which may block all nerves innervating the articular capsule, surrounding muscles and the skin involved in total hip arthroplasty, might be a promising alternative for total hip arthroplasty in ankylosing spondylitis.

  1. Preliminary validation of 2 magnetic resonance image scoring systems for osteoarthritis of the hip according to the OMERACT filter.

    PubMed

    Maksymowych, Walter P; Cibere, Jolanda; Loeuille, Damien; Weber, Ulrich; Zubler, Veronika; Roemer, Frank W; Jaremko, Jacob L; Sayre, Eric C; Lambert, Robert G W

    2014-02-01

    Development of a validated magnetic resonance image (MRI) scoring system is essential in hip OA because radiographs are insensitive to change. We assessed the feasibility and reliability of 2 previously developed scoring methods: (1) the Hip Inflammation MRI Scoring System (HIMRISS) and (2) the Hip Osteoarthritis MRI Scoring System (HOAMS). Six readers (3 radiologists, 3 rheumatologists) participated in 2 reading exercises. In Reading Exercise 1, MRI of the hip of 20 subjects were read at a single time point followed by further standardization of methodology. In Reading Exercise 2, MRI of the hip of 18 subjects from a randomized controlled trial, assessed at 2 timepoints, and 27 subjects from a cross-sectional study were read for HIMRISS and HOAMS bone marrow lesions (BML) and synovitis. Reliability was assessed using intraclass correlation coefficient (ICC) and kappa statistics. Both methods were considered feasible. For Reading 1, HIMRISS ICC were 0.52, 0.61, 0.70, and 0.58 for femoral BML, acetabular BML, effusion, and total scores, respectively; and for HOAMS, summed BML and synovitis ICC were 0.52 and 0.46, respectively. For Reading 2, HIMRISS and HOAMS ICC for BML and synovitis-effusion improved substantially. Interobserver reliability for change scores was 0.81 and 0.71 for HIMRISS femoral and HOAMS summed BML, respectively. Responsiveness and discrimination was moderate to high for synovitis-effusion. Significant associations were noted between BML or synovitis scores and Western Ontario and McMaster Universities Osteoarthritis Index pain scores for baseline values (p ≤ 0.001). The BML and synovitis-effusion components of both HIMRISS and HOAMS scoring systems are feasible and reliable, and should be validated further.

  2. Revision total hip arthoplasty: factors associated with re-revision surgery.

    PubMed

    Khatod, Monti; Cafri, Guy; Inacio, Maria C S; Schepps, Alan L; Paxton, Elizabeth W; Bini, Stefano A

    2015-03-04

    The survivorship of implants after revision total hip arthroplasty and risk factors associated with re-revision are not well defined. We evaluated the re-revision rate with use of the institutional total joint replacement registry. The purpose of this study was to determine patient, implant, and surgeon factors associated with re-revision total hip arthroplasty. A retrospective cohort study was conducted. The total joint replacement registry was used to identify patients who had undergone revision total hip arthroplasty for aseptic reasons from April 1, 2001, to December 31, 2010. The end point of interest was re-revision total hip arthroplasty. Risk factors evaluated for re-revision total hip arthroplasty included: patient risk factors (age, sex, body mass index, race, and general health status), implant risk factors (fixation type, bearing surface, femoral head size, and component replacement), and surgeon risk factors (volume and experience). A multivariable Cox proportional hazards model was used. Six hundred and twenty-nine revision total hip arthroplasties with sixty-three (10%) re-revisions were evaluated. The mean cohort age (and standard deviation) was 57.0 ± 12.4 years, the mean body mass index (and standard deviation) was 29.5 ± 6.1 kg/m(2), and most of the patients were women (64.5%) and white (81.9%) and had an American Society of Anesthesiologists score of <3 (52.9%). The five-year implant survival after revision total hip arthroplasty was 86.8% (95% confidence interval, 83.57% to 90.25%). In adjusted models, age, total number of revision surgical procedures performed by the surgeon, fixation, and bearing surface were associated with the risk of re-revision. For every ten-year increase in patient age, the hazard ratio for re-revision decreases by a factor of 0.72 (95% confidence interval, 0.58 to 0.90). For every five revision surgical procedures performed by a surgeon, the risk of revision decreases by a factor of 0.93 (95% confidence interval, 0.86 to 0.99). At the time of revision, a new or retained cemented femoral implant or all-cemented hip implant increases the risk of revision by a factor of 3.19 (95% confidence interval, 1.22 to 8.38) relative to a retained or new uncemented hip implant. A ceramic on a highly cross-linked polyethylene bearing articulation decreases the hazard relative to metal on highly cross-linked polyethylene by a factor of 0.32 (95% confidence interval, 0.11 to 0.95). Metal on constrained bearing increases the hazard relative to metal on highly cross-linked polyethylene by a factor of 3.32 (95% confidence interval, 1.16 to 9.48). When evaluating patient, implant, and surgical factors at the time of revision total hip arthroplasty, age, surgeon experience, implant fixation, and bearing surfaces had significant impacts on the risk of re-revision. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  3. Characteristics and Trends of Published Adult Hip Research over the Last Decade

    PubMed Central

    Kwak, Hong Suk; Yoon, Pil Whan; Park, Moon Seok; Kim, Hee Joong

    2015-01-01

    Purpose We designed this study to demonstrate recent trends in the proportion of adult hip research in orthopedics, to identify countries leading the adult hip research, and to evaluate the relationship between the economic power of the countries and their contributions. Materials and Methods Studies published in seven select orthopedic journals were retrieved from PubMed. Among them, we determined the number of adult hip studies. The countries-of-origin of adult hip studies, and the economic power of the countries were investigated. Results A total of 7218 orthopedic publications and 1993 (27.6%) addressed adult hip research were identified. Adult hip studies increased from 313 (23.7%) in 2000 to 555 (27.9%) in 2011. Twenty-five countries accounted for 97.6% of the total number of adult hip studies, and gross domestic product correlated with publication volume (Spearman's rho, 0.723; p=0.000). Conclusion Researchers from a limited number of developed countries have published their studies in the adult hip discipline. PMID:25510756

  4. Computer Assisted Surgery and Current Trends in Orthopaedics Research and Total Joint Replacements

    NASA Astrophysics Data System (ADS)

    Amirouche, Farid

    2008-06-01

    Musculoskeletal research has brought about revolutionary changes in our ability to perform high precision surgery in joint replacement procedures. Recent advances in computer assisted surgery as well better materials have lead to reduced wear and greatly enhanced the quality of life of patients. The new surgical techniques to reduce the size of the incision and damage to underlying structures have been the primary advance toward this goal. These new techniques are known as MIS or Minimally Invasive Surgery. Total hip and knee Arthoplasties are at all time high reaching 1.2 million surgeries per year in the USA. Primary joint failures are usually due to osteoarthristis, rheumatoid arthritis, osteocronis and other inflammatory arthritis conditions. The methods for THR and TKA are critical to initial stability and longevity of the prostheses. This research aims at understanding the fundamental mechanics of the joint Arthoplasty and providing an insight into current challenges in patient specific fitting, fixing, and stability. Both experimental and analytical work will be presented. We will examine Cementless total hip arthroplasty success in the last 10 years and how computer assisted navigation is playing in the follow up studies. Cementless total hip arthroplasty attains permanent fixation by the ingrowth of bone into a porous coated surface. Loosening of an ingrown total hip arthroplasty occurs as a result of osteolysis of the periprosthetic bone and degradation of the bone prosthetic interface. The osteolytic process occurs as a result of polyethylene wear particles produced by the metal polyethylene articulation of the prosthesis. The total hip arthroplasty is a congruent joint and the submicron wear particles produced are phagocytized by macrophages initiating an inflammatory cascade. This cascade produces cytokines ultimately implicated in osteolysis. Resulting bone loss both on the acetabular and femoral sides eventually leads to component instability. As patients are living longer and total hip arthroplasty is performed in younger patients the risks of osteolysis associated with cumulative wear is increased. Computer-assisted surgery is based on sensing feedback; vision and imaging that help surgeons align the patient's joints during total knee or hip replacement with a degree of accuracy not possible with the naked eye. For the first time, the computer feedback is essential for ligament balancing and longevity of the implants. The computers navigation systems also help surgeons to use smaller incisions instead of the traditional larger openings. Small-incision surgery offers the potential for faster recovery, less bleeding and less pain for patients. The development of SESCAN imaging technique to create a patient based model of a 3D joint will be presented to show the effective solution of complex geometry of joints.

  5. Primary total hip replacement versus hip resurfacing - hospital considerations.

    PubMed

    Ward, William G; Carter, Christina J; Barone, Marisa; Jinnah, Riyaz

    2011-01-01

    Multiple factors regarding surgical procedures and patient selection affect hospital staffing needs as well as hospital revenues. In order to better understand the potential impact on hospitals that hip arthroplasty device selection (standard total hip arthroplasty vs. resurfacing) creates, a review of all primary hip arthroplasties performed at one institution was designed to identify factors that impacted hospital staffing needs and revenue generation. All primary hip arthroplasties undertaken over three fiscal years (2008 to 2010) were reviewed, utilizing only hospital business office data and medical records data that had been previously extracted prior for billing purposes. Analysis confirmed differing demographics for two hip arthroplasty populations, with the resurfacing patients (compared to the conventional total hip arthroplasty population) consisting of younger patients (mean age, 50 vs. 61 years), who were more often male (75% vs. 45%), were more likely to have osteoarthritis as their primary diagnosis (83 vs. 67%) and were more often covered by managed care or commercial insurance (83 vs. 34%). They also had shorter hospital stays (mean length of stay, 2.3 vs. 4.1 days) and consequently provided a more favorable financial revenue stream to the hospital on a per patient basis. Several trends appeared during the study periods. There was a steady increase in all procedures in all groups except for the resurfacings, which decreased 26% in males and 53% in females between 2009 and 2010. Differences were observed in the demographics of patients presenting for resurfacing, compared to those presenting for conventional total hip arthroplasty. In addition to the revenue stream considerations, institutions undertaking a resurfacing program must commit the resources and planning in order to rehabilitate these patients more expeditiously than is usually required with conventional hip arthroplasty patients.

  6. Comparison of intrathecal and local infiltration analgesia by morphine for pain management in total knee and hip arthroplasty: A meta-analysis of randomized controlled trial.

    PubMed

    Jia, Xu-Feng; Ji, Yong; Huang, Guang-Ping; Zhou, Yu; Long, Miao

    2017-04-01

    We performed a meta-analysis from randomized controlled trials to evaluate the efficiency and safety between local infiltration analgesia and intrathecal morphine for pain control in total knee and hip arthroplasty. We systemically searched electronic databases including Embase (1980-2016.7), Medline (1966-2016.7), PubMed (1966-2016.7), ScienceDirect (1985-2016.7), web of science (1950-2016.7) and Cochrane Library for relevant articles. All calculation was carried out by Stata 11.0. Four randomized controlled trials (RCTs) involving 242 patients met the inclusion criteria. The meta-analysis showed that there were significant differences in terms of postoperative pain scores at 24 h during rest (P = 0.008) and mobilization (P = 0.049) following total knee and hip arthroplasty. Significant difference was found regarding the incidence of nausea (P = 0.030), vomiting (P = 0.005), and pruritus (P = 0.000) between two groups. There was no significant difference between groups in terms of morphine equivalent consumption at postoperative 24 or 48 h. Local infiltration analgesia (LIA) provided superior analgesic effects within the first 24 h compared to intrathecal morphine (ITM) following total knee and hip arthroplasty. There were fewer adverse effects in LIA. Doses of morphine consumption were similar in the two groups. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  7. Total medical costs of treating femoral neck fracture patients with hemi- or total hip arthroplasty: a cost analysis of a multicenter prospective study.

    PubMed

    Burgers, P T P W; Hoogendoorn, M; Van Woensel, E A C; Poolman, R W; Bhandari, M; Patka, P; Van Lieshout, E M M

    2016-06-01

    The aim of this study was to determine the total medical costs for treating displaced femoral neck fractures with hemi- or total hip arthroplasty in fit elderly patients. The mean total costs per patient at 2 years of follow-up were €26,399. These results contribute to cost awareness. The absolute number of hip fractures is rising and increases the already significant burden on society. The aim of this study was to determine the mean total medical costs per patient for treating displaced femoral neck fractures with hemi- or total hip arthroplasty in fit elderly patients. The population was the Dutch sample of an international randomized controlled trial consisting of femoral neck fracture patients treated with hemi- or total hip arthroplasty. Patient data and health care utilization were prospectively collected during a total follow-up period of 2 years. Costs were separated into costs for hospital care during primary stay, hospital costs for clinical follow-up, and costs generated outside the hospital during rehabilitation. Multiple imputations were used to account for missing data. Data of 141 participants (mean age 81 years) were included in the analysis. The 2-year mortality rate was 19 %. The mean total cost per patient after 10 weeks of follow-up was €15,216. After 1 and 2 years of follow-up the mean total costs were €23,869 and €26,399, respectively. Rehabilitation was the main cost determinant, and accounted for 46 % of total costs. Primary hospital admission days accounted for 22 % of the total costs, index surgery for 11 %, and physical therapy for 7 %. The main cost determinants for hemi- or total hip arthroplasty after treatment of displaced femoral neck fractures (€26,399 per patient until 2 years) were rehabilitation and nursing homes. Most of the costs were made in the first year. Reducing costs after hip fracture surgery should focus on improving the duration and efficiency of the rehabilitation phase.

  8. Pre-fracture individual characteristics associated with high total health care costs after hip fracture.

    PubMed

    Schousboe, J T; Paudel, M L; Taylor, B C; Kats, A M; Virnig, B A; Dowd, B E; Langsetmo, L; Ensrud, K E

    2017-03-01

    Older women with pre-fracture slow walk speed, high body mass index, and/or a high level of multimorbidity have significantly higher health care costs after hip fracture compared to those without those characteristics. Studies to investigate if targeted health care interventions for these individuals can reduce hip fracture costs are warranted. The aim of this study is to estimate the associations of individual pre-fracture characteristics with total health care costs after hip fracture, using Study of Osteoporotic Fractures (SOF) cohort data linked to Medicare claims. Our study population was 738 women age 70 and older enrolled in Medicare Fee for Service (FFS) who experienced an incident hip fracture between January 1, 1992 and December 31, 2009. We assessed pre-fracture individual characteristics at SOF study visits and estimated costs of hospitalizations, skilled nursing facility and inpatient rehabilitation stays, home health care visits, and outpatient utilization from Medicare FFS claims. We used generalized linear models to estimate the associations of predictor variables with total health care costs (2010 US dollars) after hip fracture. Median total health care costs for 1 year after hip fracture were $35,536 (inter-quartile range $24,830 to $50,903). Multivariable-adjusted total health care costs for 1 year after hip fracture were 14 % higher ($5256, 95 % CI $156 to $10,356) in those with walk speed <0.6 m/s compared to ≥1.0 m/s, 25 % higher ($9601, 95 % CI $3314 to $16,069) in those with body mass index ≥30 kg/m 2 compared to 20 to 24.9 mg/kg 2 , and 21 % higher ($7936, 95 % CI $346 to $15,526) for those with seven or more compared to no comorbid medical conditions. Pre-fracture poor mobility, obesity, and multiple comorbidities are associated with higher total health care costs after hip fracture in older women. Studies to investigate if targeted health care interventions for these individuals can reduce the costs of hip fractures are warranted.

  9. Revision hip preservation surgery with hip arthroscopy: clinical outcomes.

    PubMed

    Domb, Benjamin G; Stake, Christine E; Lindner, Dror; El-Bitar, Youseff; Jackson, Timothy J

    2014-05-01

    To analyze and report the clinical outcomes of a cohort of patients who underwent revision hip preservation with arthroscopy and determine predictors of positive and negative outcomes. During the study period from April 2008 to December 2010, all patients who underwent revision hip preservation with arthroscopy were included. This included patients who had previous open surgery and underwent revision with arthroscopy. Patient-reported outcome (PRO) scores were obtained preoperatively and at 3-month, 1-year, 2-year, and 3-year follow-up time points. Any revision surgeries and conversions to total hip arthroplasty were noted. A multiple regression analysis was performed to look for positive and negative predictive factors for improvement in PROs after revision hip arthroscopy. Forty-seven hips in 43 patients had completed 2 years' follow-up or needed total hip arthroplasty. The mean length of follow-up was 29 months (range, 24 to 47 months). Of the hips, 31 (66%) had either unaddressed or incompletely treated femoroacetabular impingement. There was a significant improvement in all PRO scores at a mean of 29 months after revision (P < .0001). The visual analog scale score improved from 7.3 ± 1.5 to 3.9 ± 2.5 (P < .0001). Improvements in the Non-Arthritic Hip Score of at least 10 points and 20 points were found in 28 hips (65%) and 19 hips (44%), respectively. Four hips in 3 patients required conversion to total hip arthroplasty. Positive predictive factors for PRO improvement were previous open surgery, pincer impingement, cam impingement, symptomatic heterotopic ossification, and segmental labral defects treated with labral reconstruction. On the basis of multiple PROs, revision hip preservation with hip arthroscopy can achieve moderately successful outcomes and remains a viable treatment strategy after failed primary hip preservation surgery. Preoperative predictors of success after revision hip arthroscopy include segmental labral defects, unaddressed or incompletely addressed femoroacetabular impingement, heterotopic ossification, and previous open surgery. Level IV, therapeutic case series. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  10. The Cost-Effectiveness of Dual Mobility Implants for Primary Total Hip Arthroplasty: A Computer-Based Cost-Utility Model.

    PubMed

    Barlow, Brian T; McLawhorn, Alexander S; Westrich, Geoffrey H

    2017-05-03

    Dislocation remains a clinically important problem following primary total hip arthroplasty, and it is a common reason for revision total hip arthroplasty. Dual mobility (DM) implants decrease the risk of dislocation but can be more expensive than conventional implants and have idiosyncratic failure mechanisms. The purpose of this study was to investigate the cost-effectiveness of DM implants compared with conventional bearings for primary total hip arthroplasty. Markov model analysis was conducted from the societal perspective with use of direct and indirect costs. Costs, expressed in 2013 U.S. dollars, were derived from the literature, the National Inpatient Sample, and the Centers for Medicare & Medicaid Services. Effectiveness was expressed in quality-adjusted life years (QALYs). The model was populated with health state utilities and state transition probabilities derived from previously published literature. The analysis was performed for a patient's lifetime, and costs and effectiveness were discounted at 3% annually. The principal outcome was the incremental cost-effectiveness ratio (ICER), with a willingness-to-pay threshold of $100,000/QALY. Sensitivity analyses were performed to explore relevant uncertainty. In the base case, DM total hip arthroplasty showed absolute dominance over conventional total hip arthroplasty, with lower accrued costs ($39,008 versus $40,031 U.S. dollars) and higher accrued utility (13.18 versus 13.13 QALYs) indicating cost-savings. DM total hip arthroplasty ceased being cost-saving when its implant costs exceeded those of conventional total hip arthroplasty by $1,023, and the cost-effectiveness threshold for DM implants was $5,287 greater than that for conventional implants. DM was not cost-effective when the annualized incremental probability of revision from any unforeseen failure mechanism or mechanisms exceeded 0.29%. The probability of intraprosthetic dislocation exerted the most influence on model results. This model determined that, compared with conventional bearings, DM implants can be cost-saving for routine primary total hip arthroplasty, from the societal perspective, if newer-generation DM implants meet specific economic and clinical benchmarks. The differences between these thresholds and the performance of other contemporary bearings were frequently quite narrow. The results have potential application to the postmarket surveillance of newer-generation DM components. Economic and decision analysis Level III. See Instructions for Authors for a complete description of levels of evidence.

  11. Cemented Total Hip Replacement Cable Debris and Acetabular Construct Durability

    PubMed Central

    Altenburg, Aaron J.; Callaghan, John J.; Yehyawi, Tameem M.; Pedersen, Douglas R.; Liu, Steve S.; Leinen, Jessica A.; Dahl, Kevin A.; Goetz, Devon D.; Brown, Thomas D.; Johnston, Richard C.

    2009-01-01

    Background: Third-body wear can adversely affect the outcome of total hip arthroplasty by causing increased polyethylene wear, osteolysis, and component loosening. We hypothesized that there would be greater generation and migration of metal debris to the bearing surfaces in hips in which cobalt-chromium cables were used to reattach the osteotomized greater trochanter when compared with hips in which stainless steel wires were used. Methods: Between June 1981 and December 1983, 196 consecutive total hip arthroplasties were performed with use of an Iowa stem and a titanium-backed cemented acetabular component, with cobalt-chromium cable trochanteric reattachment. After nineteen to twenty years of follow-up, the patients were evaluated with regard to the depth of head penetration into the polyethylene (as a surrogate for wear), osteolysis, loosening, and the need for revision. The results were compared with those for a series of 304 total hip arthroplasties that were performed by the same surgeon from January 1984 to December 1985 with use of the same components and the same surgical technique, but with stainless steel wire trochanteric reattachment. The two groups had a comparable nineteen to twenty-year follow-up. All living patients (fifty-nine hips in the cable group and ninety-two hips in the wire group) had minimum ten-year follow-up radiographs. Results: The polyethylene wear rate was 0.101 mm/yr for the cable group and 0.082 mm/yr for the wire group (p = 0.039). For the living patients, the rate of revision of the acetabular component because of aseptic loosening was 37.3% (twenty-two hips) for the cable group and 20.7% (nineteen hips) for the wire group (p = 0.025). The rate of acetabular osteolysis was 44% (twenty-six hips) for the cable group and 26% (twenty-four hips) for the wire group (p = 0.022). Kaplan-Meier analysis with revision of the acetabular component because of aseptic loosening as the end point demonstrated survival rates of 73.7% ± 9% and 83% ± 7% for the cable and wire groups, respectively, at twenty years (p = 0.03). Conclusions: Because cable trochanteric attachment led to significantly greater polyethylene wear, osteolysis, acetabular loosening, and acetabular revision, presumably due to third-body metallic debris generation in this cemented total hip replacement construct, surgeons should be aware of the deleterious effects of third-body debris and avoid the use of potential debris generators in the total hip arthroplasty construct. If cable is used and fretting is recognized, especially with intra-articular migration of metallic material or nonunion of the greater trochanter, consideration should be given to cable removal. Level of Evidence: Therapeutic Level III. See Instructions to Authors for a complete description of levels of evidence. PMID:19571089

  12. Analysis of lumbar spine and hip motion during forward bending in subjects with and without a history of low back pain.

    PubMed

    Esola, M A; McClure, P W; Fitzgerald, G K; Siegler, S

    1996-01-01

    This study analyzed two groups of subjects during forward bending. Group 1 (n = 20) contained subjects with a history of low back pain and Group 2 (n = 21) included subjects without a history of low back pain. The purposes of this study were to establish the amount and pattern of lumbar spine and hip motion during forward bending, and determine differences in motion in subjects with and without a history of low back pain. Reported values for lumbar spine motion during forward bending vary from 23.9 degrees to 60 degrees and hip motion during forward bending ranges from 26 degrees to 66 degrees. There has been no direct study of both lumbar spine and hip motion during forward bending in subjects with and without a history of low back pain to establish differences in total amounts or pattern of lumbar spine and hip motion during forward bending. A three-dimensional optoelectric motion analysis system was used to measure the amount and velocity of lumbar spine and hip motion during forward bending. Each subject performed three trials of forward bending that were averaged and used for statistical analysis. Hamstring flexibility was also assessed by two clinical tests, the passive straight leg raising and active knee extension tests. Mean total forward bending for all subjects was 111 degrees: 41.6 degrees from the lumbar spine and 69.4 degrees from the hips. There were no group differences for total amounts of lumbar spine and hip motion or velocity during forward bending. The pattern of motion was described by calculating lumbar-to-hip flexion ratios for early (0-30 degrees), middle (30-60 degrees), and late (60-90 degrees) forward bending. For all subjects, mean lumbar-to-hip ratios for early, middle, and late forward bending were 1.9, 0.9, and 0.4, respectively. Therefore, the lumbar spine had a greater contribution to early forward bending, the lumbar spine and hips contributed almost equally to middle forward bending, and the hips had a greater contribution to late forward bending. A t test revealed a difference between groups for the pattern of motion. Group 1 tended to move more at their lumbar spine during early forward bending and had a significantly lower lumbar-to-hip flexion ratio during middle forward bending (P < 0.01). Hamstring flexibility was strongly correlated to motion in subjects with a history of low back pain, but not in healthy subjects. The results provide quantitative data to guide clinical assessment of forward bending motion. Results also suggest that although people with a history of low back pain have amounts of lumbar spine and hip motion during forward bending similar to those of healthy subjects, the pattern of motion is different. It may be desirable to teach patients with a history of low back pain to use more hip motion during early forward bending, and hamstring stretching may be helpful for encouraging earlier hip motion.

  13. Hip Squeaking after Ceramic-on-ceramic Total Hip Arthroplasty

    PubMed Central

    Wu, Guo-Liang; Zhu, Wei; Zhao, Yan; Ma, Qi; Weng, Xi-Sheng

    2016-01-01

    Objective: The present study aimed to review the characteristics and influencing factors of squeaking after ceramic-on-ceramic (CoC) total hip arthroplasty (THA) and to analyze the possible mechanisms of the audible noise. Data Sources: The data analyzed in this review were based on articles from PubMed and Web of Science. Study Selection: The articles selected for review were original articles and reviews found based on the following search terms: “total hip arthroplasty”, “ceramic-on-ceramic”, “hip squeaking”, and “hip noise.” Results: The mechanism of the squeaking remains unknown. The possible explanations included stripe wear, edge loading, a third body, fracture of the ceramic liner, and resonance of the prosthesis components. Squeaking occurrence is influenced by patient, surgical, and implant factors. Conclusions: Most studies indicated that squeaking after CoC THA was the consequence of increasing wear or impingement, caused by prosthesis design, patient characteristics, or surgical factors. However, as conflicts exist among different articles, the major reasons for the squeaking remain to be identified. PMID:27453238

  14. Evaluation of Hip Internal and External Rotation Range of Motion as an Injury Risk Factor for Hip, Abdominal and Groin Injuries in Professional Baseball Players

    PubMed Central

    Ma, Richard; Zhou, Hanbing; Thompson, Matthew; Dawson, Courtney; Nguyen, Joseph; Coleman, Struan

    2015-01-01

    Normal hip range of motion (ROM) is essential in running and transfer of energy from lower to upper extremities during overhead throwing. Dysfunctional hip ROM may alter lower extremity kinematics and predispose athletes to hip and groin injuries. The purpose of this study is characterize hip internal/external ROM (Arc) and its effect on the risk of hip, hamstring, and groin injuries in professional baseball players. Bilateral hip internal and external ROM was measured on all baseball players (N=201) in one professional organization (major and minor league) during spring training. Players were organized according to their respective positions. All injuries were documented prospectively for an entire MLB season (2010 to 2011). Data was analyzed according to position and injuries during the season. Total number of players (N=201) with an average age of 24±3.6 (range=17-37). Both pitchers (N=93) and catchers (N=22) had significantly decreased mean hip internal rotation and overall hip arc of motion compared to the positional players (N=86). Players with hip, groin, and hamstring injury also had decreased hip rotation arc when compared to the normal group. Overall, there is a correlation between decreased hip internal rotation and total arc of motion with hip, hamstring, and groin injuries. PMID:26793294

  15. Invariant hip moment pattern while walking with a robotic hip exoskeleton

    PubMed Central

    Lewis, Cara L.; Ferris, Daniel P.

    2011-01-01

    Robotic lower limb exoskeletons hold significant potential for gait assistance and rehabilitation; however, we have a limited understanding of how people adapt to walking with robotic devices. The purpose of this study was to test the hypothesis that people reduce net muscle moments about their joints when robotic assistance is provided. This reduction in muscle moment results in a total joint moment (muscle plus exoskeleton) that is the same as the moment without the robotic assistance despite potential differences in joint angles. To test this hypothesis, eight healthy subjects trained with the robotic hip exoskeleton while walking on a force-measuring treadmill. The exoskeleton provided hip flexion assistance from approximately 33% to 53% of the gait cycle. We calculated the root mean squared difference (RMSD) between the average of data from the last 15 minutes of the powered condition and the unpowered condition. After completing three 30-minute training sessions, the hip exoskeleton provided 27% of the total peak hip flexion moment during gait. Despite this substantial contribution from the exoskeleton, subjects walked with a total hip moment pattern (muscle plus exoskeleton) that was almost identical and more similar to the unpowered condition than the hip angle pattern (hip moment RMSD 0.027, angle RMSD 0.134, p<0.001). The angle and moment RMSD were not different for the knee and ankle joints. These findings support the concept that people adopt walking patterns with similar joint moment patterns despite differences in hip joint angles for a given walking speed. PMID:21333995

  16. Frost decreases content of sugars, ascorbic acid and some quercetin glycosides but stimulates selected carotenes in Rosa canina hips.

    PubMed

    Cunja, Vlasta; Mikulic-Petkovsek, Maja; Zupan, Anka; Stampar, Franci; Schmitzer, Valentina

    2015-04-15

    Primary and secondary metabolites of Rosa canina hips were determined by HPLC/MS during ripening and after frost damage. Rose hips were harvested six times from the beginning of September until the beginning of December. Color parameters a*, b* and L* decreased during maturation. Glucose and fructose were the predominant sugars representing up to 92% total sugars, and citric acid was the major organic acid detected in rose hips (constituting up to 58% total organic acids). Total sugar and ascorbic acid content significantly decreased after frost damage; from 42.2 to 25.9 g 100 g(-1) DW for sugars and from 716.8 to 176.0 mg 100 g(-1) DW for ascorbic acid. Conversely, β-carotene and lycopene levels increased in frostbitten rose hips to 22.1 and 113.2 mg 100 g(-1) DW, respectively. In addition to cyanidin-3-glucoside (highest level in hips was 125.7 μg 100 g (-1) DW), 45 different phenolic compounds have been identified. The most abundant were proanthocyanidins (their levels amounted up to 90% of total flavanol content) and their content showed no significant differences during maturation. The levels of catechin, phloridzin, flavanones and several quercetin glycosides were highest on the first three sampling dates and decreased after frost. Antioxidant capacity similarly decreased in frostbitten rose hips. Total phenolic content increased until the third sampling and decreased on later samplings. Copyright © 2015 Elsevier GmbH. All rights reserved.

  17. A prospective randomised study comparing the jubilee dressing method to a standard adhesive dressing for total hip and knee replacements.

    PubMed

    Burke, Neil G; Green, Connor; McHugh, Gavin; McGolderick, Niall; Kilcoyne, Carol; Kenny, Patrick

    2012-08-01

    It is important to reduce potential wound complications in total hip and total knee arthroplasty procedures. The purpose of this study was to compare the jubilee dressing method to a standard adhesive dressing. 124 patients (62 total hip replacements and 62 total knee replacements) were randomly selected to have either a standard adhesive dressing or jubilee method dressing. The number of dressing changes, incidence of blistering, leakage, appearance of inflammation, infection rate and the average stay in hospital was recorded for each patient. The jubilee dressing significantly reduced the rate of blistering, leakage and number of dressing changes when compare to a traditional adhesive dressing (p < 0.05). The rate of inflammation and average length of stay in hospital was not significantly different between the two groups. The authors recommend the use of this dressing for total hip and total knee arthroplasty procedures due to the associated lower complication rate. Copyright © 2012 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  18. Transfusions and blood loss in total hip and knee arthroplasty: a prospective observational study.

    PubMed

    Carling, Malin S; Jeppsson, Anders; Eriksson, Bengt I; Brisby, Helena

    2015-03-28

    There is a high prevalence of blood product transfusions in orthopedic surgery. The reported prevalence of red blood cell transfusions in unselected patients undergoing hip or knee replacement varies between 21% and 70%. We determined current blood loss and transfusion prevalence in total hip and knee arthroplasty when tranexamic acid was used as a routine prophylaxis, and further investigated potential predictors for excessive blood loss and transfusion requirement. In total, 193 consecutive patients undergoing unilateral hip (n = 114) or knee arthroplasty (n = 79) were included in a prospective observational study. Estimated perioperative blood loss was calculated and transfusions of allogeneic blood products registered and related to patient characteristics and perioperative variables. Overall transfusion rate was 16% (18% in hip patients and 11% in knee patients, p = 0.19). Median estimated blood loss was significantly higher in hip patients (984 vs 789 mL, p < 0.001). Preoperative hemoglobin concentration was the only independent predictor of red blood cell transfusion in hip patients while low hemoglobin concentration, body mass index, and operation time were independent predictors for red blood cell transfusion in knee patients. The prevalence of red blood cell transfusion was lower than previously reported in unselected total hip or knee arthroplasty patients. Routine use of tranexamic acid may have contributed. Low preoperative hemoglobin levels, low body mass index, and long operation increase the risk for red blood cell transfusion.

  19. Safety measures in hip arthroscopy and their efficacy in minimizing complications: a systematic review of the evidence.

    PubMed

    Gupta, Asheesh; Redmond, John M; Hammarstedt, Jon E; Schwindel, Leslie; Domb, Benjamin G

    2014-10-01

    The purpose of this systematic review was to evaluate the literature to determine complications of hip arthroscopy, with a secondary focus on how to minimize complications and risks. Two independent reviewers performed a search of PubMed for articles that contained at least 1 of the following terms: complications and hip arthroscopy, hip impingement, femoral acetabular impingement and complications, or femoroacetabular impingement (FAI) and complications. The search was limited to articles published between 1999 and June 2013. An additional search was performed for articles evaluating techniques on how to minimize complications. We identified 81 studies (5,535 patients; 6,277 hips). The mean age was 35.48 years, and the mean body mass index was 25.20 kg/m(2). Of the participants, 52% were male and 48% were female. The majority of studies were Level IV Evidence (63%). A total of 285 complications were reported, for an overall rate of 4.5%. There were 26 major complications (0.41%) and a 4.1% minor complication rate. The overall reoperation rate was 4.03%. A total of 94 hips underwent revision arthroscopy. Regarding open procedures, 150 patients (93%) underwent either total hip arthroplasty or a hip resurfacing procedure. The conversion rate to total hip arthroplasty or a resurfacing procedure was 2.4%. Overall, primary hip arthroscopy is a successful procedure with low rates of major (0.41%) and minor (4.1%) complications. The reoperation rate was 4.03% in our review. There is admittedly a learning curve to performing hip arthroscopy, and we present a systematic review of the complications and how to minimize these complications with careful technique and planning. Level IV, systematic review of Level II to V studies. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  20. [Total hip arthroplasty through anterior "minimal invasive" approach].

    PubMed

    Moerenhout, Kevin G; Cherix, Stéphane; Rüdiger, Hannes A

    2012-12-19

    Total hip replacement has seen a tremendous development and has become one of the most successful surgical interventions in orthopaedics. While during the first decades of development of total hip arthroplasty the fixation of the implant into the bone was the main concern, the focus has shifted towards surgical technique and soft tissue handling. In order to avoid permanent soft tissue damage, muscular dysfunction and concerns in regards to cosmetics, minimal invasive and anatomic approaches have been developed. We here provide a short overview on various methods of total hip replacements and we describe our technique through a minimal invasive direct anterior approach. While muscle and nerve damage is minimal, this technique allows for a rapid rehabilitation and is associated with an excellent functional outcome and a minimal risk for dislocation.

  1. Digital versus analogue preoperative planning of total hip arthroplasties: a randomized clinical trial of 210 total hip arthroplasties.

    PubMed

    The, Bertram; Verdonschot, Nico; van Horn, Jim R; van Ooijen, Peter M A; Diercks, Ron L

    2007-09-01

    The objective of this randomized clinical trial was to compare the clinical and technical results of digital preoperative planning for primary total hip arthroplasties with analogue planning. Two hundred and ten total hip arthroplasties were randomized. All plans were constructed on standardized radiographs by the surgeon who performed the arthroplasty the next day. The main outcome was accuracy of the preoperative plan. Secondary outcomes were operation time and a radiographic assessment of the arthroplasty. Digital preoperative plans were more accurate in planning the cup (P < .05) and scored higher on the postoperative radiologic assessment of cemented cup (P = .03) and stem (P < .01) components. None of the other comparisons reached statistical significance. We conclude that digital plans slightly outperform analogue plans.

  2. [Local infiltration analgesia in total joint replacement].

    PubMed

    de Jonge, Tamás; Görgényi, Szabolcs; Szabó, Gabriella; Torkos, Miklós Bulcsú

    2017-03-01

    Total hip and knee replacment surgeries are characterized by severe postoperative pain. Local infiltration analgesia is proved to be very effective. However this method has not been widely used in Hungary. To evaluate the efficacy of the local infiltration analgesia with modified components in patients underwent total hip or knee replacement surgery. Data of 99 consecutive patients underwent primary total hip or knee replacement surgery were evaluated prospectively. In all the 99 surgeries modified local infiltration analgesia was applied. Postoperative pain reported on a visual analog scale was recorded as well as the need for further analgetics during the first 18 hours after surgery. The cost of the analgetic drugs was calculated. The control group comprised 97 consecutive patients underwent total hip or knee replacement, where local infiltration analgesia was not applied. Statistical analysis was done. Patients received local infiltration analgesia reported significantly less pain (p<0.001). The need for postoperatively given analgetics was almost 50% less, and the cost of all postoperative analgetics was 47% less than in the control group. In total hip and knee replacement surgeries the modified local infiltration analgesia decreases postoperative pain effectively and contribute to the early mobilization of the patients. Orv. Hetil., 2017, 158(9), 352-357.

  3. Two-Stage Cementless Revision Total Hip Arthroplasty for Infected Primary Hip Arthroplasties.

    PubMed

    Camurcu, Yalkin; Sofu, Hakan; Buyuk, Abdul Fettah; Gursu, Sarper; Kaygusuz, Mehmet Akif; Sahin, Vedat

    2015-09-01

    The main purpose of the present study was to analyze the clinical features, the most common infective agents, and the results of two-stage total hip revision using a teicoplanin-impregnated spacer. Between January 2005 and July 2011, 41 patients were included. At the clinical status analysis, physical examination was performed, Harris hip score was noted, isolated microorganisms were recorded, and the radiographic evaluation was performed. The mean Harris hip score was improved from 38.9 ± 9.6 points to 81.8 ± 5.8 points (P<0.05). Infection was eradicated in 39 hips. Radiographic evidence of stability was noted in 37 acetabular revision components, and all femoral stems. Two-stage revision of the infected primary hip arthroplasty is a time-consuming but a reliable procedure with high rates of success. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. The effect of unilateral osteoarthritis of the hip on postural balance disorders.

    PubMed

    Truszczyńska, Aleksandra; Trzaskoma, Zbigniew; Białecki, Jerzy; Drzał-Grabiec, Justyna; Dadura, Emilia; Rąpała, Kazimierz; Tarnowski, Adam

    2016-11-10

    Postural stability is of great importance because imbalances and muscle weakness are significant risk factors for falls experienced by the elderly. Hip arthrosis, which causes pain and gait disorders that affect balance control, is common in the ageing population. The aim of this study was to assess postural stability in patients with unilateral hip arthrosis before total hip arthroplasty. The study population consisted of 52 patients with hip arthrosis (study group) and 47 subjects with no history of clinical symptoms of hip pain. The groups did not differ statistically in terms of age and BMI. Static balance was assessed by conducting a quantitative analysis of balance reaction parameters in a quiet standing position with the eyes open and closed. Analysis of the collected data revealed numerous statistically significant differences between patients with unilateral hip arthrosis before total hip arthoplasty and the asymptomatic group for parameters tested with eyes closed (p<0.05). We observed higher values of total length of centre of pressure (COP), sway path (SP), length of COP path in the medial-lateral plane (SPML), maximal amplitude between the 2 most distant points in the medial-lateral plane (MaxML), mean COP velocity (MV), and mean COP velocity in medial-lateral (MVML) in the study group.

  5. Principles of management and results of treating the fractured femur during and after total hip arthroplasty.

    PubMed

    Greidanus, Nelson V; Mitchell, Philip A; Masri, Bassam A; Garbuz, Donald S; Duncan, Clive P

    2003-01-01

    The management of fractures of the femur during and after total hip arthroplasty can be difficult, and treatment can be fraught with complications. The ideal scenario would be one in which these fractures are prevented. It is important that the surgeon has a through understanding of the principles of managing these fractures and has access to a variety of fixation and prosthetic devices and allograft bone when necessary in order to provide the best treatment. Because periprosthetic fractures range from the very simple (requiring no surgical intervention) to the complex (requiring major revision), a classification system of these fractures aids in understanding both the principles of management and results of treatment.

  6. A comparative analysis of warfarin and low-dose heparin as thromboembolism prophylaxis in total hip replacement patinets.

    PubMed Central

    Ritter, M A; HamiltonCW

    1975-01-01

    Warfarin, low-dose heparin, or a combination of low-dose heparin and hydrocortisone was administered to 300 patients undergoing total hip replacement. The lowest incidence of thromboembolic (5 per cent) was attained with Warfarin. Further investigation into the method of administration of low-dose heparin is necessary before it can be used effectively as thromboembolism prophylaxis in total hip replacement patients. The addition of hydrocortisone was not found useful. PMID:1138642

  7. Is there a new learning curve with transition to a new resurfacing system?

    PubMed

    Johnson, Aaron J; Costa, Christopher R; Naziri, Qais; Mont, Michael A

    2011-01-01

    Metal-on-metal hip resurfacing has been proven to be a successful option for treating hip osteoarthritis in young, active patients. However, compared to a standard primary hip arthroplasty, hip resurfacing has a higher degree of technical difficulty. While all resurfacing systems utilize similar principles, there can be some variation in surgical technique. The purpose of this study was to determine if there was a second learning curve when a surgeon transitioned from one hip resurfacing system to another. In 2007, the senior investigator (MAM) transitioned from using one resurfacing system for a majority of his patients to a different system. The records of 200 resurfacings were reviewed, including the last 150 patients who underwent this procedure prior to the switch, and who were then compared with the first 50 patients using a newer system. The mean age and mean body mass index (BMI) of the patients in the prior 150-patient group was 53 years and 28 kg/m2, respectively, compared to a mean age of 51 years and a mean BMI of 29 kg/m2 in the newer system group. The mean follow-up for the prior 150 patients was 45 months (range, 40 to 50 months), compared to 31 months (range, 25 to 37 months) for the first 50 receiving the new system. Clinical survivorship and complications were monitored, and clinical outcomes were evaluated using Harris hip scores. The implant survival rate of the last 150 patients regarding the first resurfacing system was 97.3 (146/150), compared to 100% survival with the second system. The mean Harris hip score improved from 61 points (range, 40 to 76 points) to 93 points (range, 50 to 100 points) in the first group and from 52 points (range, 31 to 83 points) to 97 points (range, 86 to 100 points) in the latter group. There were four revisions: three for femoral neck fractures and one for unexplained groin pain; two revisions were in the postoperative period, and one was 1-year postoperative and the other 2-years postoperative. Of these four revisions, all had femoral component sizes smaller than 48 mm and were revised to total hip arthroplasty; all are doing well at the most recent follow-up (Harris hip scores greater than 80 points). This study illustrates that there is no additional learning curve when transitioning from one re-surfacing system to another for an experienced surgeon. It also reinforces the previously established criteria that only well-selected patients should have a hip resurfacing arthroplasty performed in order to minimize the likelihood of postoperative complications such as femoral neck fracture. The learning curve appears to be a phenomenon that only occurs once for resurfacing and is not related to the specific implant manufacturer, but rather to the nature of the operation itself.

  8. Relationship between Physical Impairments and Movement Patterns During Gait in Patients With End-stage Hip Osteoarthritis

    PubMed Central

    Zeni, Joseph; Pozzi, Federico; Abujaber, Sumayah; Miller, Laura

    2014-01-01

    Patients with hip osteoarthritis demonstrate limited range of motion, muscle weakness and altered biomechanics; however, few studies have evaluated the relationships between physical impairments and movement asymmetries. The purpose of this study was to identify the physical impairments related to movement abnormalities in patients awaiting total hip arthroplasty. We hypothesized that muscle weakness and pain would be related to greater movement asymmetries. Fifty-six subjects who were awaiting total hip arthroplasty were enrolled. Pain was assessed using a 0 to 10 scale, range of motion was assessed with the Harris Hip Score and isometric hip abductor strength was tested using a hand-held dynamometer. Trunk, pelvis and hip angles and moments in the frontal and sagittal planes were measured during walking using three dimensional motion analysis. During gait, subjects had 3.49 degrees less peak hip flexion and 8.82 degrees less extension angles (p<0.001) and had 0.03 Nm/k*m less hip abduction moment on the affected side (p=0.043). Weaker hip muscles were related to greater pelvis (r=−0.291) and trunk (r=−0.332) rotations in the frontal plane. These findings suggest that hip weakness drives abnormal movement patterns at the pelvis and trunk in patients with hip osteoarthritis to a greater degree than hip pain. PMID:25492583

  9. Total hip arthroplasty in chronic dialysis patients in the United States.

    PubMed

    Abbott, Kevin C; Bucci, Jay R; Agodoa, Lawrence Y

    2003-01-01

    The national incidence of and factors associated with total hip arthroplasty (THA) in chronic dialysis patients has never been reported. We therefore performed an historical cohort study of 375,857 chronic dialysis patients listed in the 2000 United States Renal Data System between 1 April 1995 and 31 December 1999 and followed-up until 14 May 2000. Primary outcomes were associations with hospitalizations for a primary discharge code of THA (ICD9 procedure code 81.51x) after initiation of dialysis. Dialysis patients had a cumulative incidence of THA of 35 episodes/10,000 person-years, compared to 5.3/10,000 in the general population. The leading indication for THA was osteoarthritis of the hip and pelvis (58% of cases). However, the strongest risk factor for THA in dialysis patients was end-stage renal disease (ESRD) due to systemic lupus erythematosus (SLE, adjusted rate ratio (ARR), 6.80, 95% CI 4.62-10.03, in whom avascular necrosis of the hip was the most common indication, 68.4%). The database did not include information on use of corticosteroids. Diabetic recipients were significantly less likely to receive THA, as were males, and African Americans. Mortality after THA was 0.25% at thirty days and 30% at three years, not significantly different from the expected mortality of dialysis, adjusted for comorbidity. The most common indication for THA in dialysis patients is osteoarthritis of the hip, similar to the general population. Patients with SLE are more likely to receive THA which is well tolerated and not associated with increased mortality in this population, perhaps reflecting selection bias due to appropriate screening for this elective procedure.

  10. Hip and knee replacement in osteogenesis imperfecta.

    PubMed

    Papagelopoulos, P J; Morrey, B F

    1993-04-01

    Five total hip and three total knee arthroplasties were performed, from 1969 to 1990, in six patients who had osteogenesis imperfecta. The patients who had a hip arthroplasty were followed for a mean of seven years, and those who had a knee arthroplasty, for a mean of ten years. Postoperatively, all had relief of pain and were able to walk; one patient used a walker and two used a cane. The only postoperative complication was an intrapelvic protrusion of the acetabular component six years after a bipolar hip replacement.

  11. Lower Lean Mass Measured by Dual-Energy X-ray Absorptiometry (DXA) is Not Associated with Increased Risk of Hip Fracture in Women: The Framingham Osteoporosis Study.

    PubMed

    McLean, Robert R; Kiel, Douglas P; Berry, Sarah D; Broe, Kerry E; Zhang, Xiaochun; Cupples, L Adrienne; Hannan, Marian T

    2018-01-05

    Although muscle mass influences strength in older adults, it is unclear whether low lean mass measured by dual-energy X-ray absorptiometry (DXA) is an independent risk factor for hip fracture. Our objective was to determine the association between DXA lean mass and incident hip fracture risk among 1978 women aged 50 years and older participating in the Framingham Study Original and Offspring cohorts. Leg and total body lean mass (kg) were assessed from whole-body DXA scans collected in 1992-2001. Hip fracture follow-up extended from DXA assessment to the occurrence of fracture, death, drop-out, or end of follow-up in 2007. Cox proportional hazards regression was used to calculate hazard ratios (HR) and 95% confidence intervals (CI) estimating the relative risk of hip fracture associated with a 1-kg increase in baseline lean mass. Mean age was 66 years (range 50-93). Over a median of 8 years of follow-up, 99 hip fractures occurred. In models adjusted for age, height, study cohort, and percent total body fat, neither leg (HR 1.11; 95% CI 0.94, 1.31) nor total body (HR 1.06; 95% CI 0.99, 1.13) lean mass were associated with hip fracture. After further adjustment for femoral neck bone mineral density, leg lean mass results were similar (HR 1.10; 95% CI 0.93, 1.30). In contrast, 1 kg greater total body lean mass was associated with 9% higher hip fracture risk (HR 1.09; 95% CI 1.02, 1.18). Our findings suggest that in women, lower lean mass measured by DXA is not associated with increased risk of hip fracture.

  12. The Bimetric cementless total hip replacement: 7-18 year follow-up assessing the influence of acetabular design on survivorship.

    PubMed

    Russell, R C; Ghassemi, A; Dorrell, J H; Powles, D P

    2009-08-01

    The purpose of this study was to evaluate the mid- to long-term survivorship of Bimetric cementless total hip replacement and assess how it is affected by the acetabular design. This was a retrospective analysis of 127 Bimetric cementless total hip replacements in 110 patients with a follow-up of 7-18 years. A single design stem and three different cementless metal-backed acetabular designs were used. Patients were assessed clinically using the Harris hip score and radiologically by independent review of current hip radiographs. There was only one case of aseptic loosening of the femoral stem. The earliest acetabular design showed a high failure rate whilst the latter two designs showed a 96% survivorship at a mean of 9.5 years. We conclude that a combination of the bimetric stem with either of the latter acetabular cup designs has a good mid- to long-term performance.

  13. The Cost of Joint Replacement: Comparing Two Approaches to Evaluating Costs of Total Hip and Knee Arthroplasty.

    PubMed

    Palsis, John A; Brehmer, Thomas S; Pellegrini, Vincent D; Drew, Jacob M; Sachs, Barton L

    2018-02-21

    In an era of mandatory bundled payments for total joint replacement, accurate analysis of the cost of procedures is essential for orthopaedic surgeons and their institutions to maintain viable practices. The purpose of this study was to compare traditional accounting and time-driven activity-based costing (TDABC) methods for estimating the total costs of total hip and knee arthroplasty care cycles. We calculated the overall costs of elective primary total hip and total knee replacement care cycles at our academic medical center using traditional and TDABC accounting methods. We compared the methods with respect to the overall costs of hip and knee replacement and the costs for each major cost category. The traditional accounting method resulted in higher cost estimates. The total cost per hip replacement was $22,076 (2014 USD) using traditional accounting and was $12,957 using TDABC. The total cost per knee replacement was $29,488 using traditional accounting and was $16,981 using TDABC. With respect to cost categories, estimates using traditional accounting were greater for hip and knee replacement, respectively, by $3,432 and $5,486 for personnel, by $3,398 and $3,664 for space and equipment, and by $2,289 and $3,357 for indirect costs. Implants and consumables were derived from the actual hospital purchase price; accordingly, both methods produced equivalent results. Substantial cost differences exist between accounting methods. The focus of TDABC only on resources used directly by the patient contrasts with the allocation of all operating costs, including all indirect costs and unused capacity, with traditional accounting. We expect that the true costs of hip and knee replacement care cycles are likely somewhere between estimates derived from traditional accounting methods and TDABC. TDABC offers patient-level granular cost information that better serves in the redesign of care pathways and may lead to more strategic resource-allocation decisions to optimize actual operating margins.

  14. The effect of stem design on the prevalence of squeaking following ceramic-on-ceramic bearing total hip arthroplasty.

    PubMed

    Restrepo, Camilo; Post, Zachary D; Kai, Brandon; Hozack, William J

    2010-03-01

    The ceramic-on-ceramic bearing for total hip arthroplasty has an extremely low wear rate and demonstrates minimal inflammatory response in comparison with other bearing choices. However, acoustic emissions such as squeaking and clicking are being reported as annoying complications related to its use. The cause or causes of this phenomenon have not been determined. The purpose of the present study was to evaluate the possibility that design aspects of the femoral component may be a contributing factor to the etiology of squeaking associated with the ceramic-on-ceramic bearing total hip arthroplasty. We retrospectively reviewed 266 consecutive patients (304 hips) who had undergone total hip arthroplasty with use of ceramic-on-ceramic bearings. The first 131 consecutive patients (152 hips) (Group 1) received a hydroxyapatite-coated stem composed of titanium-aluminum-vanadium alloy with a C-taper neck geometry and robust midsection with an anteroposterior diameter of 13 mm. The second 135 consecutive patients (152 hips) (Group 2) also received a hydroxyapatite-coated stem, but in that group the stem was composed of titanium-molybdenum-zirconium-iron alloy, with a V-40 neck geometry and a midsection with an anteroposterior thickness of only 10 mm. All 304 hips received the same cup, composed of titanium-aluminum-vanadium alloy. Demographic characteristics, such as age, sex, height, weight, and body mass index, were similar in both groups. Data regarding the presence of squeaking were obtained prospectively. Patients who were seen for clinical follow-up either expressed the squeaking phenomenon themselves or were asked about it by the physician. Patients who were not seen at a recent clinical follow-up visit were contacted by telephone and were asked specifically about squeaking that might be associated with the hip replacement. Only patients with confirmed squeaking noise were included in the present study. Postoperative radiographs, the Short Form-36 health survey, the Harris hip score, and office or telephone interviews of the patient were used to determine the overall outcome of the procedure. The prevalence of squeaking was seven times higher for patients who received the titanium-molybdenum-zirconium-iron-alloy stem (twenty-seven patients, twenty-eight hips [18.4%]) than in those who received the titanium-aluminum-vanadium-alloy stem (three patients, four hips [2.6%]); this difference was significant (p < 0.0001). Our study suggests that different stem alloys, stem geometries, or neck geometries can have an impact on the frequency of squeaking following a ceramic-on-ceramic total hip arthroplasty.

  15. Direct medical costs attributable to peripheral fractures in Canadian post-menopausal women.

    PubMed

    Bessette, L; Jean, S; Lapointe-Garant, M-P; Belzile, E L; Davison, K S; Ste-Marie, L G; Brown, J P

    2012-06-01

    This study determined the cost of treating fractures at osteoporotic sites (except spine fractures) for the year following fracture. While the average cost of treating a hip fracture was the highest of all fractures ($46,664 CAD per fracture), treating other fractures also accounted for significant expenditures ($5,253 to $10,410 CAD per fracture). This study aims to determine the mean direct medical cost of treating fractures at peripheral osteoporotic sites in the year post-fracture (through 2 years post-hip fracture). Health administrative databases from the province of Quebec, Canada were used to estimate the cost of treating peripheral fractures at osteoporotic sites for the year following fracture (through 2 years for hip fractures). Included in costs analyses were physician claims, emergency and outpatient clinic costs, hospitalization costs, and subsequent costs for treatment of complications. A total of 15,827 patients (mean age 72 years) who suffered one fracture at an osteoporotic site had data for analyses. Hip/femur fractures had the highest rate of hospital stays related to fracture (91%) and the highest rate of hospital stays associated with a post-fracture complication (8%). In the year following fracture, the mean (SD) costs (2009 Canadian dollars) of treating acute fractures and post-fracture complications were: hip/femur fracture $46,664 ($43,198), wrist fracture $5,253 ($18,982), and fractures at other peripheral sites $10,410 ($27,641). The average (SD) cost of treating post-fracture complications at the hip/femur in the second year post-fracture was $1,698 ($12,462). Hospitalizations associated with the fracture accounted for 88% of the total cost of fracture treatment. The treatment of hip fractures accounts for a significant proportion of the costs associated with the treatment of peripheral osteoporotic fractures. Interventions to reduce the incidence of fractures, particularly hip fractures, would result in significant cost savings to the health care system and would preserve quality of life in many patients.

  16. Nationwide cohort study of hip fractures: time trends in the incidence rates and projections up to 2035.

    PubMed

    Chen, I-J; Chiang, C-Y F; Li, Y-H; Chang, C-H; Hu, C-C; Chen, D W; Chang, Y; Yang, W-E; Shih, H-N; Ueng, S W-N; Hsieh, P-H

    2015-02-01

    A growing elderly population is expected worldwide, and the burden of hip fractures on health care system will continue to increase. By 2035, there will be a 2.7-fold increase in the number of hip fractures in Taiwan. The study provides quantitative basis for the future distribution of medical resources. Hip fractures have long been recognized as a major public health concern. The study aimed to determine time trends in the incidence of hip fractures and to forecast the number of hip fractures expected in Taiwan up to 2035. A nationwide survey was conducted using data from the Taiwan National Health Insurance Research Database from 2004 to 2011. A total of 141,397 hip fractures were identified, with a mean of 17,675 fractures/year. Annual incidences of hip fractures were calculated and tested for trends. Projections of the incidence rates of hip fractures and bed days associated with hip fractures were calculated using Poisson regression on the historical incidence rates in combination with population projections from 2012 to 2035. The incidence rates of hip fracture during 2004-2011 were 317 and 211 per 100,000 person-years among women and men, respectively. Over this 8-year period, the age-standardized incidence of hip fracture decreased by 13.4% among women and 12.2% among men. Despite the decline in the age-standardized incidence, the absolute number of hip fractures increased owing to the aging population. The number of hip fractures is expected to increase from 18,338 in 2010 to 50,421 in 2035-a 2.7-fold increase. The number of bed days for 2010 and 2035 was estimated at 161,248 and 501,995, respectively, representing a 3.1-fold increase. The socioeconomic impact of hip fractures will be high in the near future. This study provides a quantitative basis for future policy decisions to serve this need.

  17. Experience with Designing and Implementing a Bundled Payment Program for Total Hip Replacement

    PubMed Central

    Whitcomb, Winthrop F.; Lagu, Tara; Krushell, Robert J.; Lehman, Andrew P.; Greenbaum, Jordan; McGirr, Joan; Pekow, Penelope S.; Calcasola, Stephanie; Benjamin, Evan; Mayforth, Janice; Lindenauer, Peter K.

    2015-01-01

    Background Bundled payments, also known as episode-based payments, are intended to contain health care costs and promote quality. In 2011 a bundled payment pilot program for total hip replacement was implemented by an integrated health care delivery system in conjunction with a commercial health plan subsidiary. In July 2015 the Centers for Medicare & Medicaid Services (CMS) proposed the Comprehensive Care for Joint Replacement Model to test bundled payment for hip and knee replacement. Methods Stakeholders were identified and a structure for program development and implementation was created. An Oversight Committee provided governance over a Clinical Model Subgroup and a Financial Model Subgroup. Results The pilot program included (1) a clinical model of care encompassing the period from the preoperative evaluation through the third postoperative visit, (2) a pricing model, (3) a program to share savings, and (4) a patient engagement and expectation strategy. Compared to 32 historical controls— patients treated before bundle implementation—45 post-bundle-implementation patients with total hip replacement had a similar length of hospital stay (3.0 versus 3.4 days, p = .24), higher rates of discharge to home or home with services than to a rehabilitation facility (87% versus 63%), similar adjusted median total payments ($22,272 versus $22,567, p = .43), and lower median posthospital payments ($704 versus $1,121, p = .002), and were more likely to receive guideline-consistent care (99% versus 95%, p = .05). Discussion The bundled payment pilot program was associated with similar total costs, decreased posthospital costs, fewer discharges to rehabilitation facilities, and improved quality. Successful implementation of the program hinged on buy-in from stakeholders and close collaboration between stakeholders and the clinical and financial teams. PMID:26289235

  18. Experience with Designing and Implementing a Bundled Payment Program for Total Hip Replacement.

    PubMed

    Whitcomb, Winthrop F; Lagu, Tara; Krushell, Robert J; Lehman, Andrew P; Greenbaum, Jordan; McGirr, Joan; Pekow, Penelope S; Calcasola, Stephanie; Benjamin, Evan; Mayforth, Janice; Lindenauer, Peter K

    2015-09-01

    Bundled payments, also known as episode-based payments, are intended to contain health care costs and promote quality. In 2011 a bundled payment pilot program for total hip replacement was implemented by an integrated health care delivery system in conjunction with a commercial health plan subsidiary. In July 2015 the Centers for Medicare & Medicaid Services (CMS) proposed the Comprehensive Care for Joint Replacement Model to test bundled payment for hip and knee replacement. Stakeholders were identified and a structure for program development and implementation was created. An Oversight Committee provided governance over a Clinical Model Subgroup and a Financial Model Subgroup. The pilot program included (1) a clinical model of care encompassing the period from the preoperative evaluation through the third postoperative visit, (2) a pricing model, (3) a program to share savings, and (4) a patient engagement and expectation strategy. Compared to 32 historical controls-patients treated before bundle implementation-45 post-bundle-implementation patients with total hip replacement had a similar length of hospital stay (3.0 versus 3.4 days, p=.24), higher rates of discharge to home or home with services than to a rehabilitation facility (87% versus 63%), similar adjusted median total payments ($22,272 versus $22,567, p=.43), and lower median posthospital payments ($704 versus $1,121, p=.002), and were more likely to receive guideline-consistent care (99% versus 95%, p=.05). The bundled payment pilot program was associated with similar total costs, decreased posthospital costs, fewer discharges to rehabilitation facilities, and improved quality. Successful implementation of the program hinged on buy-in from stakeholders and close collaboration between stakeholders and the clinical and financial teams.

  19. Duration and frequency of every day activities in total hip patients.

    PubMed

    Morlock, M; Schneider, E; Bluhm, A; Vollmer, M; Bergmann, G; Müller, V; Honl, M

    2001-07-01

    Little knowledge about frequency and duration of daily activities in patients after total hip arthroplasty is available. Such information is required for the definition of realistic load collectives for pre-clinical testing of prostheses. It could also be helpful for the quantitative evaluation of surgery outcome with different prosthesis types. The purpose of this study was to develop and apply a system for the determination of frequency and duration of patient activities in their habitual environment and to compare the results to a clinical outcome score (Harris hip score).A portable activity monitoring system (weight 1.6 kg including batteries) was designed using a Palm top computer, 2 inclination sensors for the thigh and calf and one goniometer positioned at the knee joint. An algorithm was developed to identify frequency and duration of the activities lying, sitting, standing, walking and stair climbing from the signals of the 3 sensors. 42 patients participated in the study and were equipped with the system in the morning at their home. Datasets of 31 patients (age 62.5+/-11.5 y) covered more than 6h (9.8 +/- 1.6 h) and were included in the analysis. Prosthesis specific data as well as the Harris hip score were collected. The most frequent patient activity was sitting (44.3% of the time), followed by standing (24.5%), walking (10.2%), lying (5.8%) and stair climbing (0.4%). The median number of steps/stairs was 6048/164. The number of step cycles representing one year in vivo use should, consequently, be increased to 1.1 million. The Harris hip score (91.4 +/- 9.8) correlated significantly with the number of stairs (r(2) = 0.26, p = 0.003) and showed a positive tendency with the number of steps per day. No differences in activity levels between prosthesis specific factors were found.

  20. Contemporary Strategies for Rapid Recovery Total Hip Arthroplasty.

    PubMed

    Stambough, Jeffrey B; Beaulé, Paul E; Nunley, Ryan M; Clohisy, John

    2016-01-01

    Over the past several years, rapid recovery protocols for total hip arthroplasty have evolved in parallel with advancements in pain management, regional anesthesia, focused rehabilitation, and the patient selection process. As fiscal pressures from payers of health care increase, surgical outcomes and complications are being scrutinized, which evokes a sense of urgency for arthroplasty surgeons as well as hospitals. The implementation of successful accelerated recovery pathways for total hip arthroplasty requires the coordinated efforts of surgeons, practice administrators, anesthesiologists, nurses, physical and occupational therapists, case managers, and postacute care providers. To optimize performance outcomes, it is important for surgeons to select patients who are eligible for rapid recovery. The fundamental tenets of multimodal pain control, regional anesthesia, prudent perioperative blood management, venous thromboembolic prophylaxis, and early ambulation and mobility should be collectively addressed for all patients who undergo primary total hip replacement.

  1. Manual therapy intervention for a patient with a total hip arthroplasty revision.

    PubMed

    Howard, Paul D; Levitsky, Beth

    2007-12-01

    Case report. A 73-year-old active woman with a total hip arthroplasty, who later had revision surgery, developed left hip and buttock pain 2 years after the revision surgery, subsequent to lifting her foot while seated. This movement was performed so that her spouse could assist her in putting on her sock and shoe. During the first physical therapy session, the patient exhibited a forward-flexed trunk posture and difficulty weight bearing on the involved lower limb. The patient was successfully treated with manual therapy techniques and a home exercise program. The manual therapy techniques included long-axis hip distraction, lateral hip distraction, posterior-to-anterior hip joint mobilization, and a contract-relax proprioceptive neuromuscular facilitation technique. The patient's home program consisted of long-axis hip distraction, performed by her spouse, and standing lower limb pendular movements into flexion and extension. Pain scale ratings, posture and gait observations, strength, range of motion, and return to functional activities served as outcome measures. After 1 physical therapy visit, in which manual therapy techniques were utilized, the patient had a significant decrease in hip symptoms. The patient and spouse were compliant with the home exercise program and continued with physical therapy for 3 more visits, and the patient ultimately became symptom free. The patient returned to all previous activities, including household chores, cooking, and a walking program. The patient was contacted at 6 months, 1 year, and 4 years, and reported no recurrences of hip or buttock symptoms. Manual therapy techniques and home exercises described in this case report were apparently effective in eliminating symptoms and returning this patient, who had total hip arthroplasty and revision surgery 2 years earlier, to all previous functional activities after a dressing incident produced hip and buttock symptoms.

  2. Calcaneal stress fracture: an adverse event following total hip and total knee arthroplasty: a report of five cases.

    PubMed

    Miki, Takaaki; Miki, Takahito; Nishiyama, Akihiro

    2014-01-15

    Stress fractures have been reported to occur in the pubis, femoral neck, proximal part of the tibia, and fabella during the postoperative period following total knee or total hip arthroplasty. However, to our knowledge, calcaneal stress fractures after total hip or total knee arthroplasty have not been reported in the English-language literature. Most orthopaedic surgeons are not familiar with calcaneal stress fractures that may occur in elderly patients after a total knee or total hip arthroplasty. We retrospectively reviewed the clinical features, imaging findings, and bone mineral content of the proximal part of the femur and the distal end of the radius in five patients who had a calcaneal stress fracture after a total knee or total hip arthroplasty. All patients were women with a mean age of 76.8 years. All fractures occurred in the calcaneus on the same side as the arthroplasty. The fracture appeared at a mean of 10.2 weeks postoperatively. All patients reported heel pain on walking. Swelling and local heat were found in four and three patients, respectively. Pain was elicited by squeezing the calcaneus in all patients. Early radiographs had normal findings in two patients, and an irregular sclerotic line appeared later in the radiographs of all patients. All fractures were treated conservatively. Four fractures healed uneventfully, but one fracture displaced. All patients had osteoporosis. Calcaneal stress fractures during the postoperative period following total knee or total hip arthroplasty may not be as rare as previously thought. Because clinical symptoms of the fracture appear insidiously and radiographic findings are absent or subtle in the early stage, a high index of suspicion is needed for orthopaedic surgeons to make the correct diagnosis. Magnetic resonance imaging or repeated radiographs may be necessary to make the correct diagnosis when no abnormality is apparent on the initial radiograph.

  3. Invariant hip moment pattern while walking with a robotic hip exoskeleton.

    PubMed

    Lewis, Cara L; Ferris, Daniel P

    2011-03-15

    Robotic lower limb exoskeletons hold significant potential for gait assistance and rehabilitation; however, we have a limited understanding of how people adapt to walking with robotic devices. The purpose of this study was to test the hypothesis that people reduce net muscle moments about their joints when robotic assistance is provided. This reduction in muscle moment results in a total joint moment (muscle plus exoskeleton) that is the same as the moment without the robotic assistance despite potential differences in joint angles. To test this hypothesis, eight healthy subjects trained with the robotic hip exoskeleton while walking on a force-measuring treadmill. The exoskeleton provided hip flexion assistance from approximately 33% to 53% of the gait cycle. We calculated the root mean squared difference (RMSD) between the average of data from the last 15 min of the powered condition and the unpowered condition. After completing three 30-min training sessions, the hip exoskeleton provided 27% of the total peak hip flexion moment during gait. Despite this substantial contribution from the exoskeleton, subjects walked with a total hip moment pattern (muscle plus exoskeleton) that was almost identical and more similar to the unpowered condition than the hip angle pattern (hip moment RMSD 0.027, angle RMSD 0.134, p<0.001). The angle and moment RMSD were not different for the knee and ankle joints. These findings support the concept that people adopt walking patterns with similar joint moment patterns despite differences in hip joint angles for a given walking speed. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Minimally invasive hip arthroplasty: what role does patient preconditioning play?

    PubMed

    Pour, Aidin Eslam; Parvizi, Javad; Sharkey, Peter F; Hozack, William J; Rothman, Richard H

    2007-09-01

    The benefits of minimally invasive total hip arthroplasty continue to be debated. The objective of this study was to investigate the role of patient education, accelerated rehabilitation, and improved pain control on the outcome of total hip arthroplasty performed through a small incision. One hundred patients undergoing total hip arthroplasty at our institution were randomized into one of four groups on the basis of the size of the incision, preoperative counseling, the type of preoperative and postoperative rehabilitation, and the analgesia protocol. The operative parameters, complications, time to discharge to home, functional improvement, and patient satisfaction were assessed. The demographic distribution among the four groups was similar. The extent of functional improvement at the time of discharge to home, patient satisfaction, and walking ability at the time of discharge were better in patients who had received an accelerated preoperative and postoperative rehabilitation regimen regardless of the size of the incision. There was no difference in estimated blood loss, mean operative time, transfusion needs, or complications among the groups. This study highlights the importance of factors such as family education, patient preconditioning, preemptive analgesia, and accelerated preoperative and postoperative rehabilitation in influencing the outcome of total hip arthroplasty. The aforementioned factors, and not the surgical technique per se, may play a major role in imparting the better outcome after minimally invasive total hip arthroplasty that has been reported by various investigators.

  5. Primary cementless total hip arthroplasty with second-generation metal-on-metal bearings: a concise follow-up, at a minimum of seventeen years, of a previous report.

    PubMed

    Lass, R; Grübl, A; Kolb, A; Domayer, S; Csuk, C; Kubista, B; Giurea, A; Windhager, R

    2014-03-05

    Second-generation, metal-on-metal bearings were introduced in 1988, to reduce wear and avoid polyethylene particle-induced osteolysis from total hip arthroplasty. In 2007, we reported the long-term results of ninety-eight patients (105 hips) who underwent primary cementless total hip arthroplasty involving the use of a prosthesis with a high-carbide-concentration, metal-on-metal articulating surface between November 1992 and May 1994. The present study gives an update on this patient cohort. At a minimum of seventeen years postoperatively, forty-nine patients (fifty-two hips) were available for follow-up examination. We retrospectively evaluated clinical and radiographic results as well as serum metal concentration. The mean patient age at the time of the index arthroplasty was fifty-six years. Three cups (6% of the hips) and one stem (2% of the hips) were revised because of aseptic loosening of the implants combined with focal osteolysis. At the time of the latest follow-up evaluation, the mean Harris hip score was 88.8 points, and the mean University of California Los Angeles (UCLA) activity score was 6.7 points. The cumulative rate of implant survival, with aseptic failure as the end point, was 93.0% at 18.8 years. The median serum cobalt concentration in patients whose hip implant was the only source of cobalt was 0.70 μg/L (range, 0.4 to 5.1 μg/L), showing no increase in the value as noted at a minimum of ten years of follow-up. The clinical and radiographic results of our study, which, to our knowledge, represent the longest duration of follow-up for a series of cementless total hip arthroplasties with use of a 28-mm metal-on-metal bearing, continue to be comparable with the results observed for other hard-on-hard bearings.

  6. Preoperative digital planning versus postoperative outcomes in total hip arthroplasty using a calcar-guided short stem: frequent valgization can be avoided.

    PubMed

    Kutzner, Karl Philipp; Pfeil, Joachim; Kovacevic, Mark Predrag

    2017-07-01

    Modern total hip arthroplasty is largely dependent on the successful preservation of hip geometry. Thus, a successful implementation of the preoperative planning is of great importance. The present study evaluates the accuracy of anatomic hip reconstruction predicted by 2D digital planning using a calcar-guided short stem of the newest generation. A calcar-guided short stem was implanted in 109 patients in combination with a cementless cup using the modified anterolateral approach. Preoperative digital planning was performed including implant size, caput-collum-diaphyseal angle, offset, and leg length using mediCAD II software. A coordinate system and individual scale factors were implemented. Postoperative outcome was evaluated accordingly and was compared to the planning. Intraoperatively used stem sizes were within one unit of the planned stem sizes. The postoperative stem alignment showed a minor and insignificant (p = 0.159) mean valgization of 0.5° (SD 3.79°) compared to the planned caput-collum-diaphyseal angles. Compared to the planning, mean femoral offset gained 2.18 (SD 4.24) mm, while acetabular offset was reduced by 0.78 (SD 4.36) mm during implantation resulting in an increased global offset of 1.40 (SD 5.51) mm (p = 0.0094). Postoperative femoroacetabular height increased by a mean of 5.00 (SD 5.98) mm (p < 0.0001) compared to preoperative measures. Two-dimensional digital preoperative planning in calcar-guided short-stem total hip arthroplasty assures a satisfying implementation of the intended anatomy. Valgization, which has been frequently observed in previous short-stem designs, negatively affecting offset, can be avoided. However, surgeons have to be aware of a possible leg lengthening.

  7. Non-sedentary Lifestyle Can Reduce Hip Fracture Risk among Older Caucasians Adults: The Adventist Health Study-2.

    PubMed

    Lousuebsakul-Matthews, Vichuda; Thorpe, Donna; Knutsen, Raymond; Beeson, W Larry; Fraser, Gary E; Knutsen, Synnove F

    2015-01-01

    The beneficial effect of physical activity on reducing hip fracture risk has been supported in many previous studies. The present cohort study explores the relationship between total daily physical activity expressed as MET-hour/day and hip fracture risk among men over 50 years of age and postmenopausal women (n=22,836). Associations between self-reported hip fracture incidence and total daily physical activity and selected lifestyle factors were assessed using Cox proportional hazard regression. In gender-specific multivariable models, total activity above average (≥ 51 MET-hours per day for men, ≥ 48 MET-hours per day for women) compared to those with sedentary lifestyle (< 40 MET-hours per day) reduced the risk of hip fracture by 60% among men (HR=0.40, 95%CI: 0.23-0.70) (Ptrend=0.002) and 48% among women (HR=0.52, 95%CI: 0.32-0.84) (Ptrend=0.01). Our findings suggest that a moderate level of physical activity and avoiding a sedentary lifestyle can reduce the risk of hip fracture among the elderly.

  8. The effectiveness of inpatient physical therapy compared to outpatient physical therapy in older adults after total hip replacement in the post-discharge period: a systematic review.

    PubMed

    Klugarova, Jitka; Klugar, Miloslav; Mareckova, Jana; Gallo, Jiri; Kelnarova, Zuzana

    2016-01-01

    Total hip replacement is the most effective and safest method for treating severe degenerative, traumatic and other diseases of the hip joint. Total hip replacement can reliably relieve pain and improve function in the majority of patients for a period of 15 to 20 years or more postoperatively. Physical therapy follows each total hip replacement surgery. Physical therapy protocols after total hip replacement in the post-discharge period vary widely in terms of setting (inpatient, outpatient), content (the particular set of exercises used), and frequency (e.g. daily versus twice a week). In current literature, there is no systematic review which has compared the effectiveness of inpatient and outpatient physical therapy in patients after total hip replacement in the post-discharge period. The objective of this systematic review was to compare the effectiveness of inpatient physical therapy with outpatient physical therapy on the quality of life and gait measures in older adults after total hip replacement in the post-discharge period. This review considered studies that include older adults (over 65 years) who have had total hip replacement and are in the post-discharge period. Adults with bilateral or multiple simultaneous surgeries and also patients who have had hemiarthroplasty of the hip joint were excluded.This review considered studies that included any type of physical therapy delivered in inpatient settings provided by professionals with education in physical therapy. Inpatient physical therapy delivered at any frequency and over any duration was included.This review considered studies that included as a comparator any type of physical therapy delivered in outpatient settings provided by professionals with education in physical therapy or no physical therapy.This review considered studies that included the following primary and secondary outcomes. The primary outcome was quality of life, assessed by any validated assessment tool. The secondary outcome was measures of gait assessed by any valid methods.This review considered both experimental and observational study designs including randomized controlled trials, non-randomized controlled trials, quasi-experimental, before and after studies, prospective and retrospective cohort studies, case control studies and analytical cross sectional studies for inclusion. The search strategy aimed to find both published and unpublished studies. A three-step search strategy was utilized in 12 databases. Studies published in all languages and any date were considered for inclusion in this review. Assessment of methodological quality was not conducted as no studies were identified that met the inclusion criteria. Data extraction and synthesis was not performed because no studies were included in this systematic review. During to the three-step search strategy 4330 papers were identified. The primary and secondary reviewer independently retrieved 42 potentially relevant papers according to the inclusion criteria by title and abstract screening. Following assessment of full text all of the retrieved papers were excluded based on the inclusion criteria. There is no scientific evidence comparing the effectiveness of inpatient physical therapy with outpatient physical therapy in older patients after total hip replacement in the post-discharge period. This systematic review has identified gaps in the literature for comparing the effectiveness of inpatient physical therapy with and outpatient physical therapy on the quality of life and gait measures in older adults after total hip replacement in the post-discharge period. Prospective randomized double blind multicenter controlled trials are needed to answer this important clinical question.

  9. Bilateral total hip arthroplasty in Morquio-Brailsford's syndrome: a report of two cases.

    PubMed

    Tassinari, Enrico; Boriani, Luca; Traina, Francesco; Dallari, Dante; Toni, Aldo; Giunti, Armando

    2008-09-01

    We report two cases of bilateral cementless total hip arthroplasty in two young women affected by Morquio-Brailsford syndrome. Morquio-Brailsford disease belongs to the mucopolysaccharidoses; it shows growth retardation with disproportional dwarfism. Usually patients are affected by a severe joint degeneration from their 2nd or 3rd decade. Young age, severe dysplasia, and joint size are the main technical problems for a total hip replacement. Accurate radiographic and CT planning allows the use of standard prostheses instead of custom-made ones.

  10. Patterns of postural deformity in non-ambulant people with cerebral palsy: what is the relationship between the direction of scoliosis, direction of pelvic obliquity, direction of windswept hip deformity and side of hip dislocation?

    PubMed

    Porter, David; Michael, Shona; Kirkwood, Craig

    2007-12-01

    To investigate: (a) associations between the direction of scoliosis, direction of pelvic obliquity, direction of windswept deformity and side of hip subluxation/ dislocation in non-ambulant people with cerebral palsy; and (b) the lateral distribution of these postural asymmetries. Cross-sectional observational study. Posture management services in three centres in the UK. Non-ambulant people at level five on the gross motor function classification system for cerebral palsy. Direction of pelvic obliquity and lateral spinal curvature determined from physical examination, direction of windswept hip deformity derived from range of hip abduction/adduction, and presence/side of unilateral hip subluxation defined by hip migration percentage. A total of 747 participants were included in the study, aged 6-80 years (median 18 years 10 months). Associations between the direction of scoliosis and direction of pelvic obliquity, and between the direction of windswept hip deformity and side hip subluxation/dislocation were confirmed. A significant association was also seen between the direction of scoliosis and the direction of the windswept hip deformity (P<0.001) such that the convexity of the lateral spinal curve was more likely to be opposite to the direction of windsweeping. Furthermore, significantly more windswept deformities to the right (P=0.007), hips subluxed on the left (P=0.002) and lateral lumbar/lower thoracic spinal curves convex to the left (P=0.03) were observed. The individual asymmetrical postural deformities are not unrelated in terms of direction and not equally distributed to the left/right. A pattern of postural deformity was observed.

  11. Patterns of postural deformity in non-ambulant people with cerebral palsy: what is the relationship between the direction of scoliosis, direction of pelvic obliquity, direction of windswept hip deformity and side of hip dislocation?

    PubMed Central

    Michael, Shona; Kirkwood, Craig

    2008-01-01

    Objective: To investigate: (a) associations between the direction of scoliosis, direction of pelvic obliquity, direction of windswept deformity and side of hip subluxation/dislocation in non-ambulant people with cerebral palsy; and (b) the lateral distribution of these postural asymmetries. Design: Cross-sectional observational study. Setting: Posture management services in three centres in the UK. Subjects: Non-ambulant people at level five on the gross motor function classification system for cerebral palsy. Main measures: Direction of pelvic obliquity and lateral spinal curvature determined from physical examination, direction of windswept hip deformity derived from range of hip abduction/adduction, and presence/side of unilateral hip subluxation defined by hip migration percentage. Results: A total of 747 participants were included in the study, aged 6–80 years (median 18 years 10 months). Associations between the direction of scoliosis and direction of pelvic obliquity, and between the direction of windswept hip deformity and side hip subluxation/dislocation were confirmed. A significant association was also seen between the direction of scoliosis and the direction of the windswept hip deformity (P < 0.001) such that the convexity of the lateral spinal curve was more likely to be opposite to the direction of windsweeping. Furthermore, significantly more windswept deformities to the right (P = 0.007), hips subluxed on the left (P = 0.002) and lateral lumbar/lower thoracic spinal curves convex to the left (P = 0.03) were observed. Conclusions: The individual asymmetrical postural deformities are not unrelated in terms of direction and not equally distributed to the left/right. A pattern of postural deformity was observed. PMID:18042604

  12. Trends in reporting of mechanisms and incidence of hip injuries in males playing minor ice hockey in Canada: a cross-sectional study.

    PubMed

    Ayeni, Olufemi R; Kowalczuk, Marcin; Farag, Jordan; Farrokhyar, Forough; Chu, Raymond; Bedi, Asheesh; Willits, Kevin; Bhandari, Mohit

    2014-01-01

    There has been a noted increase in the diagnosis and reporting of sporting hip injuries and conditions in the medical literature but reporting at the minor hockey level is unknown. The purpose of this study is to investigate the trend of reporting hip injuries in amateur ice hockey players in Canada with a focus on injury type and mechanism. A retrospective review of the Hockey Canada insurance database was performed and data on ice hockey hip injuries reported between January 2005 and June 2011 were collected. The study population included all male hockey players from Peewee (aged 11-12 years) to Senior (aged 20+ years) participating in amateur level competition sanctioned by Hockey Canada. Reported cases of ice hockey hip injuries were analyzed according to age, mechanism of injury, and injury subtype. Annual injury reporting rates were determined and using a linear regression analysis trended to determine the change in ice hockey hip injury reporting rate over time. One hundred and six cases of ice hockey-related hip injuries were reported in total. The majority of injuries (75.5%) occurred in players aged 15-20 years playing at the Junior level. Most injuries were caused by a noncontact mechanism (40.6%) and strains were the most common subtype (50.0%). From 2005 to 2010, the number of reported hip injuries increased by 5.31 cases per year and the rate of reported hip injury per 1,000 registered players increased by 0.02 cases annually. Reporting of hip injuries in amateur ice hockey players is increasing. A more accurate injury reporting system is critical for future epidemiologic studies to accurately document the rate and mechanism of hip injury in amateur ice hockey players.

  13. A Multi-centre Study to Assess the Long-term Performance of the Summit™ Hip in Primary Total Hip Replacement

    ClinicalTrials.gov

    2016-08-03

    Rheumatoid Arthritis; Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis

  14. Prometheus payment model: application to hip and knee replacement surgery.

    PubMed

    Rastogi, Amita; Mohr, Beth A; Williams, Jeffery O; Soobader, Mah-Jabeen; de Brantes, Francois

    2009-10-01

    The Prometheus Payment Model offers a potential solution to the failings of the current fee-for-service system and various forms of capitation. At the core of the Prometheus model are evidence-informed case rates (ECRs), which include a bundle of typical services that are informed by evidence and/or expert opinion as well as empirical data analysis, payment based on the severity of patients, and allowances for potentially avoidable complications (PACs) and other provider-specific variations in payer costs. We outline the methods and findings of the hip and knee arthroplasty ECRs with an emphasis on PACs. Of the 2076 commercially insured patients undergoing hip arthroplasty in our study, PAC costs totaled $7.8 million (14% of total costs; n = 699 index PAC stays). Similarly, PAC costs were $12.7 million (14% of total costs; n = 897 index PAC stays) for 3403 patients undergoing knee arthroplasty. By holding the providers clinically and financially responsible for PACs, and by segmenting and quantifying the type of PACs generated during and after the procedure, the Prometheus model creates an opportunity for providers to focus on the reduction of PACs, including readmissions, making the data actionable and turn the waste related to PAC costs into potential savings.

  15. The History of Biomechanics in Total Hip Arthroplasty.

    PubMed

    Houcke, Jan Van; Khanduja, Vikas; Pattyn, Christophe; Audenaert, Emmanuel

    2017-01-01

    Biomechanics of the hip joint describes how the complex combination of osseous, ligamentous, and muscular structures transfers the weight of the body from the axial skeleton into the appendicular skeleton of the lower limbs. Throughout history, several biomechanical studies based on theoretical mathematics, in vitro , in vivo as well as in silico models have been successfully performed. The insights gained from these studies have improved our understanding of the development of mechanical hip pathologies such as osteoarthritis, hip fractures, and developmental dysplasia of the hip. The main treatment of end-stage degeneration of the hip is total hip arthroplasty (THA). The increasing number of patients undergoing this surgical procedure, as well as their demand for more than just pain relief and leading an active lifestyle, has challenged surgeons and implant manufacturers to deliver higher function as well as longevity with the prosthesis. The science of biomechanics has played and will continue to play a crucial and integral role in achieving these goals. The aim of this article, therefore, is to present to the readers the key concepts in biomechanics of the hip and their application to THA.

  16. The epidemiology of bearing surface usage in total hip arthroplasty in the United States.

    PubMed

    Bozic, Kevin J; Kurtz, Steven; Lau, Edmund; Ong, Kevin; Chiu, Vanessa; Vail, Thomas P; Rubash, Harry E; Berry, Daniel J

    2009-07-01

    Hard-on-hard bearings offer the potential to improve the survivorship of total hip arthroplasty implants. However, the specific indications for the use of these advanced technologies remain controversial. The purpose of this study was to characterize the epidemiology of bearing surface utilization in total hip arthroplasty in the United States with respect to patient, hospital, geographic, and payer characteristics. The Nationwide Inpatient Sample database was used to analyze bearing type and demographic characteristics associated with 112,095 primary total hip arthroplasties performed in the United States between October 1, 2005, and December 31, 2006. The prevalence of each type of total hip arthroplasty bearing was calculated for population subgroups as a function of age, sex, census region, payer class, and hospital type. The most commonly reported bearing was metal-on-polyethylene (51%) followed by metal-on-metal (35%) and ceramic-on-ceramic (14%). Metal-on-polyethylene bearings were most commonly reported in female Medicare patients who were sixty-five to seventy-four years old, while metal-on-metal and ceramic-on-ceramic bearings were most commonly reported in privately insured male patients who were less than sixty-five years old. Thirty-three percent of patients over sixty-five years old had a hard-on-hard bearing reported. There was substantial regional variation in bearing usage; the highest prevalence of metal-on-polyethylene bearings was reported in the Northeast and at nonteaching hospitals, and the highest prevalence of metal-on-metal bearings was reported in the South and at teaching hospitals. The usage of total hip arthroplasty bearings varies considerably by patient characteristics, hospital type, and geographic location throughout the United States. Despite uncertain advantages in older patients, hard-on-hard bearings are commonly used in patients over the age of sixty-five years. Further study is necessary to define the appropriate indications for these advanced technologies in total hip arthroplasty.

  17. World Hip Trauma Evaluation (WHiTE): framework for embedded comprehensive cohort studies.

    PubMed

    Costa, Matthew L; Griffin, Xavier L; Achten, Juul; Metcalfe, David; Judge, Andrew; Pinedo-Villanueva, Rafael; Parsons, Nicholas

    2016-10-21

    Osteoporotic hip fractures present a significant global challenge to patients, clinicians and healthcare systems. It is estimated that hip fracture accounts for 1.4% of total social and healthcare costs in the established market economies. The World Hip Trauma Evaluation (WHiTE) was set up to measure outcome in a comprehensive cohort of UK patients with hip fracture. All patients in the cohort are treated under a single comprehensive treatment pathway. A core outcome set, including health-related quality of life, is collected on all the patients. This protocol describes the current multicentre project that will be used as a vehicle to deliver a series of embedded observational studies. Research Ethics Committee approval was granted (Rec reference 11/LO/0927, approved 18/8/2011) and each hospital trust provided National Health Service (NHS) approvals. The study is registered with National Institute of Health Research Portfolio (UKCRN ID 12351) and the ISRCTN registry (ISRCTN63982700). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  18. Cementless total hip arthroplasty for severely dislocated hips previously treated with Schanz osteotomy of the proximal femur.

    PubMed

    Akman, Yunus Emre; Yavuz, Umut; Çetinkaya, Engin; Gür, Volkan; Gül, Murat; Demir, Bilal

    2018-03-01

    We report the short-term outcomes of total hip arthroplasty(THA) in patients previously treated with Schanz osteotomy (SO). Eighteen patients [2 male, 16 female; mean age, 55.4 (range, 50-66) years] who had undergone THA after SO were retrospectively evaluated. Clinical evaluation was performed based on the Harris hip score. Radiological evaluation was performed using full-length radiographs of the lower extremities, pelvis, and hip. The mean follow-up period was 30.8 (range, 18-56) months. Mean femoral shortening was 3.7 (range, 2-5) cm. Perioperative complications occurred in 4 (22.2%) patients. Nonunion was not found at the osteotomy sites. No dislocation was observed. The Trendelenburg sign was positive for five (27.7%) patients, postoperatively. The mean Harris hip score improved from 42.7 to 78.7 (p < 0.05). THA for hips previously treated with SO is technically demanding. If careful preoperative planning is performed, successful treatment can be achieved.

  19. Complication Rates for Hip Arthroscopy Are Underestimated: A Population-Based Study.

    PubMed

    Truntzer, Jeremy N; Hoppe, Daniel J; Shapiro, Lauren M; Abrams, Geoffrey D; Safran, Marc

    2017-06-01

    To identify major and minor complication rates associated with hip arthroscopy from a payer-based national database and compare with the rates reported in the existing literature. Patients who underwent hip arthroscopy between 2007 and 2014 were identified using PearlDiver, a publicly available database. Rates of major and minor complications, as well as conversion to total hip arthroscopy (THA), were determined by using Current Procedural Terminology (CPT) and International Classification of Diseases, Ninth Revision (ICD-9), codes. Incidence rates of select major complications across the entire database were used as a comparison group. Statistical significance was set at P < .05. Of 18 million patients screened from 2007 to 2014, a total of 2,581 hip arthroscopies were identified. The rates of major and minor complications within a 1-year postoperative period were 1.74% and 4.22%, respectively. Complications included heterotopic ossification (2.85%), bursitis (1.23%), proximal femur fracture (1.08%), deep vein thrombosis (0.79%), and hip dislocation (0.58%). The rate of conversion to THA within 1 year was 2.85%. When compared to rates in the general population, the relative risks [RRs] of requiring a THA (age <50 years, RR = 57.66, P < .001; age >50 years, RR = 22.05, P < .001), sustaining a proximal femur fracture (age <50 years, RR = 18.02, P < .001; age >50 years, RR = 2.23, P < .001), or experiencing a hip dislocation (RR 19.60, P < .001) at 1 year after hip arthroscopy were significantly higher in all age groups. Higher major complication rates after hip arthroscopy were observed using a national payer-based database than previously reported in the literature, especially in regard to hip dislocations and proximal femur fractures. Rates of total hip arthroplasty were similar to prior studies, whereas the rates of revision hip arthroscopy were higher. Level IV, case series. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  20. Treatment of primary hip osteoarthritis for the primary care physician and the indications for total hip arthroplasty.

    PubMed

    Levine, Mathew E; Nace, James; Kapadia, Bhaveen H; Issa, Kimona; Banerjee, Samik; Cherian, Jeffery J; Mont, Michael A

    2013-01-01

    Osteoarthritis is a degenerative condition that commonly affects knees and hips with an annual incidence of 88 in 100,000 people in the United States. The purpose of this study was to review the clinical presentation of osteoarthritis of the hip as well as the available management options. We reviewed the recent literature in regard to epidemiology, presentation, and treatment options available to patients. Nonoperative treatments include weight loss and low-impact, aerobic exercises. Along with weight loss and exercise, nonsteroidal anti-inflammatory drugs (NSAIDS), narcotics, and intra-articular steroid injections have been used to improve patient's symptoms. Surgical intervention is a viable option; however, indications such as severe pain that is refractory to nonsurgical management, osteophytes, or joint space narrowing on radiographic films, or impairment of function should be present. The most common surgical option, total hip arthroplasty, has been shown to improve a patient's physical and psychological well-being. However, inherent risks are present with surgery and these should be addressed with the patient so a sound decision can be made. Osteoarthritis of the hip can be bothersome to patients, but physicians can begin management with lifestyle changes or pharmaceuticals. In the event nonoperative measures fail to markedly improve quality of life, total hip arthroplasty remains a viable option.

  1. Aspirin or Rivaroxaban for VTE Prophylaxis after Hip or Knee Arthroplasty.

    PubMed

    Anderson, David R; Dunbar, Michael; Murnaghan, John; Kahn, Susan R; Gross, Peter; Forsythe, Michael; Pelet, Stephane; Fisher, William; Belzile, Etienne; Dolan, Sean; Crowther, Mark; Bohm, Eric; MacDonald, Steven J; Gofton, Wade; Kim, Paul; Zukor, David; Pleasance, Susan; Andreou, Pantelis; Doucette, Steve; Theriault, Chris; Abianui, Abongnwen; Carrier, Marc; Kovacs, Michael J; Rodger, Marc A; Coyle, Doug; Wells, Philip S; Vendittoli, Pascal-Andre

    2018-02-22

    Clinical trials and meta-analyses have suggested that aspirin may be effective for the prevention of venous thromboembolism (proximal deep-vein thrombosis or pulmonary embolism) after total hip or total knee arthroplasty, but comparisons with direct oral anticoagulants are lacking for prophylaxis beyond hospital discharge. We performed a multicenter, double-blind, randomized, controlled trial involving patients who were undergoing total hip or knee arthroplasty. All the patients received once-daily oral rivaroxaban (10 mg) until postoperative day 5 and then were randomly assigned to continue rivaroxaban or switch to aspirin (81 mg daily) for an additional 9 days after total knee arthroplasty or for 30 days after total hip arthroplasty. Patients were followed for 90 days for symptomatic venous thromboembolism (the primary effectiveness outcome) and bleeding complications, including major or clinically relevant nonmajor bleeding (the primary safety outcome). A total of 3424 patients (1804 undergoing total hip arthroplasty and 1620 undergoing total knee arthroplasty) were enrolled in the trial. Venous thromboembolism occurred in 11 of 1707 patients (0.64%) in the aspirin group and in 12 of 1717 patients (0.70%) in the rivaroxaban group (difference, 0.06 percentage points; 95% confidence interval [CI], -0.55 to 0.66; P<0.001 for noninferiority and P=0.84 for superiority). Major bleeding complications occurred in 8 patients (0.47%) in the aspirin group and in 5 (0.29%) in the rivaroxaban group (difference, 0.18 percentage points; 95% CI, -0.65 to 0.29; P=0.42). Clinically important bleeding occurred in 22 patients (1.29%) in the aspirin group and in 17 (0.99%) in the rivaroxaban group (difference, 0.30 percentage points; 95% CI, -1.07 to 0.47; P=0.43). Among patients who received 5 days of rivaroxaban prophylaxis after total hip or total knee arthroplasty, extended prophylaxis with aspirin was not significantly different from rivaroxaban in the prevention of symptomatic venous thromboembolism. (Funded by the Canadian Institutes of Health Research; ClinicalTrials.gov number, NCT01720108 .).

  2. Walking efficiency before and after total hip replacement.

    PubMed

    Brown, M; Hislop, H J; Waters, R L; Porell, D

    1980-10-01

    The energy cost of walking and gait characteristics of patients with hip disease were studied to determine changes in walking efficiency following total hip replacement. Twenty-nine patients, 24 with unilateral hip disease and 5 with bilateral hip disease, were tested preoperatively and at various times postoperatively. Oxygen uptake was measured by a modified Douglas bag procedure. The temporal and distance characteristics of gait were measured with contact closing heel switches. Results showed postoperative increases in velocity, cadence, and stride length in patients with unilateral disease and with bilateral disease with bilateral replacement. After surgery, energy cost tended toward more normal levels, but the subjects were not within normal limits for oxygen uptake per minute, oxygen uptake per distance walked, or percent of predicted maximum aerobic capacity. Comparison of energy expenditure data with temporal and distance factors of gait indicated that all subjects became more physiologically efficient after hip replacement.

  3. Discharge destination following hip fracture: comparative effectiveness and cost analyses.

    PubMed

    Pitzul, Kristen B; Wodchis, Walter P; Kreder, Hans J; Carter, Michael W; Jaglal, Susan B

    2017-09-30

    This study determines outcomes and costs of similar hip fracture patients that were discharged from hospital to a rehabilitation facility or to the community within 1 year. Community patients had worse outcomes and lower costs compared to rehabilitation facility patients. This study contributes to understanding hip fracture quality of care. The purpose of this study is to determine the impact on mortality and rehospitalization, as well as health system cost, of similar hip fracture patients being discharged to an inpatient rehabilitation facility or directly to the community within 1 year in Ontario, Canada. This was a retrospective study of a propensity-matched cohort completed from the health system perspective. Administrative databases were used to identify and match two groups of older adults (total n = 18,773) discharged alive from acute care for hip fracture repair: patients discharged to inpatient rehabilitation were matched to patients discharged to the community. A higher proportion of patients discharged to the community (27-42%) died or were rehospitalized (SD highipr  = 0.21, SD lowipr  = 0.33) and had substantially lower health system costs (SD highipr  = 0.65, SD lowipr  = 0.42) up to 1 year post-acute discharge compared to similar patients discharged to inpatient rehabilitation facilities (IPR) (10-11%). This study demonstrates that similar hip fracture patients are discharged to different post-acute settings (i.e., home-based rehabilitation and inpatient rehabilitation) and have different outcomes, thereby calling into question the appropriateness of post-acute rehabilitation delivery in Ontario, Canada. Future research should focus on determining how trade-offs in resource allocation between settings would impact patient outcomes.

  4. Computer-Based Training Methods for Surgical Training

    DTIC Science & Technology

    2009-10-07

    c1J:Ptollmottetv 1an-2cm _,round the J»’l~l.a. Slightly ft ex.the knee " "d lt!move the ooep Ulird of 100 fat Pid. Rtt Pc1lell• Gimbe either everted...pcrtormed to restore norma l fum:tio n o f the musculosk~let£~1 system a lter acute injury ( eg fracture of a bone ). or to treat long standing defom1ities...Enoxaparin in the Prevention of Deep Vein Thrombosis and Symptomatic Pulmonary Embolism After Elective Hip Replacement or Revision Total Hip

  5. Time Burden of Standardized Hip Questionnaires.

    PubMed

    Chughtai, Morad; Khlopas, Anton; Mistry, Jaydev B; Gwam, Chukwuweike U; Elmallah, Randa K; Mont, Michael A

    2016-04-01

    Many standardized scales and questionnaires have been developed to assess outcomes of patients undergoing total hip arthroplasty (THA). However, these surveys can be a burden to both patients and orthopaedists as some are time-inefficient. In addition, there is a paucity of reports assessing the time it takes to complete them. In this study we aimed to: (1) assess how long it takes to complete the most common standardized hip questionnaires; (2) determine the presence of variation in completion time; and (3) evaluate the effects of age, gender, and level of education on completion time. Based on a previous study, we selected the seven most commonly used hip scoring systems-Western Ontario and McMaster Universities Hip Outcome Assessment (WOMAC), Harris Hip Score (HHS), Hip Disability and Osteoarthritis Outcome Score (HOOS), Larson Score, Short-form 36 (SF-36), modified Merle d'Aubigne and Postel Score (MDA), and Lower Extremity Functional Scale (LEFS). The standardized scales and questionnaires were randomly administered to 70 subjects. The subjects were unaware that they were being timed during completion of the questionnaire. We obtained the coefficients of variation of time for each questionnaire. The mean time to complete the questionnaire was then stratified and compared based on age, gender, and level of education. The mean time to complete each of the systems is listed in ascending order: Modified Merle d'Aubigne and Postel Score (MDA), Lower Extremity Functional Scale (LEFS), Western Ontario and McMaster Universities Hip Outcome Assessment (WOMAC), Harris Hip Score (HHS), Larson Score, Hip Disability and Osteoarthritis Outcome Score (HOOS), and Short-form 36 (SF-36). The WOMAC and Larson Score coefficients of variation were the largest, and the HOOS and MDA were the smallest. There was a significantly higher mean time to completion in those who were above or equal to the age of 55 years as compared to those who were below the age of 55 (227 vs. 166 seconds). There was no significant association found in time of completion between gender or education level. Standardized scales and questionnaire which assess THA patients can be burdensome and time-inefficient, which may lead to task-induced fatigue. This may result in inaccurate THA patient assessments, which do not reflect the patient's true state. Future studies should aim to create an encompassing questionnaire that is time efficient and can replace all currently used validated systems.

  6. Reliability and concurrent validity of the Dutch hip and knee replacement expectations surveys

    PubMed Central

    2010-01-01

    Background Preoperative expectations of outcome of total hip and knee arthroplasty are important determinants of patients' satisfaction and functional outcome. Aims of the study were (1) to translate the Hospital for Special Surgery Hip Replacement Expectations Survey and Knee Replacement Expectations Survey into Dutch and (2) to study test-retest reliability and concurrent validity. Methods Patients scheduled for total hip (N = 112) or knee replacement (N = 101) were sent the Dutch Expectations Surveys twice with a 2 week interval to determine test-retest reliability. To determine concurrent validity, the Expectation WOMAC was sent. Results The results for the Dutch Hip Replacement Expectations Survey revealed good test-retest reliability (ICC 0.87), no bias and good internal consistency (alpha 0.86) (N = 72). The correlation between the Hip Expectations Score and the Expectation WOMAC score was 0.59 (N = 86). The results for the Dutch Knee Replacement Expectations Survey revealed good test-retest reliability (ICC 0.79), no bias and good internal consistency (alpha 0.91) (N = 46). The correlation with the Expectation WOMAC score was 0.52 (N = 57). Conclusions Both Dutch Expectations Surveys are reliable instruments to determine patients' expectations before total hip or knee arthroplasty. As for concurrent validity, the correlation between both surveys and the Expectation WOMAC was moderate confirming that the same construct was determined. However, patients scored systematically lower on the Expectation WOMAC compared to the Dutch Expectation Surveys. Research on patients' expectations before total hip and knee replacement has only been performed in a limited amount of countries. With the Dutch Expectations Surveys it is now possible to determine patients' expectations in another culture and healthcare setting. PMID:20958990

  7. Reliability and concurrent validity of the Dutch hip and knee replacement expectations surveys.

    PubMed

    van den Akker-Scheek, Inge; van Raay, Jos J A M; Reininga, Inge H F; Bulstra, Sjoerd K; Zijlstra, Wiebren; Stevens, Martin

    2010-10-19

    Preoperative expectations of outcome of total hip and knee arthroplasty are important determinants of patients' satisfaction and functional outcome. Aims of the study were (1) to translate the Hospital for Special Surgery Hip Replacement Expectations Survey and Knee Replacement Expectations Survey into Dutch and (2) to study test-retest reliability and concurrent validity. Patients scheduled for total hip (N = 112) or knee replacement (N = 101) were sent the Dutch Expectations Surveys twice with a 2 week interval to determine test-retest reliability. To determine concurrent validity, the Expectation WOMAC was sent. The results for the Dutch Hip Replacement Expectations Survey revealed good test-retest reliability (ICC 0.87), no bias and good internal consistency (alpha 0.86) (N = 72). The correlation between the Hip Expectations Score and the Expectation WOMAC score was 0.59 (N = 86). The results for the Dutch Knee Replacement Expectations Survey revealed good test-retest reliability (ICC 0.79), no bias and good internal consistency (alpha 0.91) (N = 46). The correlation with the Expectation WOMAC score was 0.52 (N = 57). Both Dutch Expectations Surveys are reliable instruments to determine patients' expectations before total hip or knee arthroplasty. As for concurrent validity, the correlation between both surveys and the Expectation WOMAC was moderate confirming that the same construct was determined. However, patients scored systematically lower on the Expectation WOMAC compared to the Dutch Expectation Surveys. Research on patients' expectations before total hip and knee replacement has only been performed in a limited amount of countries. With the Dutch Expectations Surveys it is now possible to determine patients' expectations in another culture and healthcare setting.

  8. Total hip arthroplasty and perioperative oral carbohydrate treatment: a randomised, double-blind, controlled trial.

    PubMed

    Harsten, Andreas; Hjartarson, Hjörtur; Toksvig-Larsen, Sören

    2012-06-01

    Perioperative oral carbohydrate intake is beneficial to general surgery patients. Total hip arthroplasty is a common surgical procedure, and even a moderate improvement in patient outcome could have a significant effect on the resources needed for these patients. However, few studies have focused on the effects of carbohydrate intake on orthopaedic patients. The purpose of this study was to investigate if perioperative oral carbohydrate intake alters the postoperative course for patients undergoing total hip arthroplasty. The primary hypothesis was that pain scores would be lower in patients treated with carbohydrate. A randomised, double-blind, controlled trial. This study was carried out between September 2009 and April 2011 at a district Swedish hospital that specialises in orthopaedic surgery. Sixty ASA physical status I-III patients scheduled for elective total hip arthroplasty were included. Exclusion criteria were obesity, diabetes, prior hip surgery to the same hip, ongoing infection, immunological deficiency or age less than 50 or more than 80 years. Patients were given 400 ml of either an oral 12.5% carbohydrate solution or a placebo beverage (flavoured water) 1.5 h before and 2 h after surgery. Visual analogue scales were used to score six discomfort parameters. Immediately prior to surgery, the carbohydrate-treated patients were less hungry (median score 9.5 vs. 22 mm) and experienced less nausea (0 vs. 1.5 mm) (P< 0.05). Postoperatively, patients in the carbohydrate group experienced less pain at 12, 16 and 20 h (median scores 20, 30 and 34 vs. 7, 5 and 0 mm; P<0.05). This study shows that there is limited benefit from administering oral carbohydrate prior to total hip arthroplasty.

  9. Total Hip Arthroplasty in Haemophilic Patients with Modern Cementless Implants.

    PubMed

    Carulli, Christian; Felici, Irene; Martini, Caterina; Civinini, Roberto; Linari, Silvia; Castaman, Giancarlo; Innocenti, Massimo

    2015-10-01

    Hip arthropathy due to recurrent haemarthrosis in patients with haemophilia can be disabling. When severe degeneration occurs, total hip arthroplasty is indicated. Reported outcomes are variable and out of date. The aim of this study is to evaluate the survivorship of Total Hip Arthroplasty performed in a patient population with modern cementless implants. Twenty-three haemophilic patients were treated and followed by a multidisciplinary team dedicated to haemophilia. The mean age was 40.6 years. No failures or complications were recorded at a mean follow-up of 8.1 years (range: 3.1-13.7). A multidisciplinary team and the use of modern cementless implants may represent the keys to achieve good outcomes, fewer complications, and better survivorship in the approach to these difficult cases. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Fracture of Fully-coated Femoral Stem after Primary Total Hip Arthroplasty for Nonunion of Intertrochanteric Fracture: A Case Report.

    PubMed

    Chun, Young Soo; Juh, Hyung Suk; Cho, Yoon Je; Rhyu, Kee Hyung

    2015-09-01

    Femoral stem fracture is an uncommon reason for the failure of total hip arthroplasty, with only 16 cases of fully coated stem fractures reported to date. Here we report a case in which a fully coated primary femoral stem fracture occurred after conversion to total hip arthroplasty for the non-union of an intertrochanteric fracture of the femur. Metallurgic evaluation of the etiology and mechanism revealed that the fracture was initiated by fatigue-related failure and completed by ductile failure on the posterior side of the fracture. Considering the recent trend of treating an intertrochanteric fracture with hip arthroplasty, possible stem failure should be considered, since most patients will have at least one of the known risk factors for stem fracture.

  11. Fracture of Fully-coated Femoral Stem after Primary Total Hip Arthroplasty for Nonunion of Intertrochanteric Fracture: A Case Report

    PubMed Central

    Chun, Young Soo; Juh, Hyung Suk; Cho, Yoon Je

    2015-01-01

    Femoral stem fracture is an uncommon reason for the failure of total hip arthroplasty, with only 16 cases of fully coated stem fractures reported to date. Here we report a case in which a fully coated primary femoral stem fracture occurred after conversion to total hip arthroplasty for the non-union of an intertrochanteric fracture of the femur. Metallurgic evaluation of the etiology and mechanism revealed that the fracture was initiated by fatigue-related failure and completed by ductile failure on the posterior side of the fracture. Considering the recent trend of treating an intertrochanteric fracture with hip arthroplasty, possible stem failure should be considered, since most patients will have at least one of the known risk factors for stem fracture. PMID:27536622

  12. The effect of patient age at intervention on risk of implant revision after total replacement of the hip or knee: a population-based cohort study.

    PubMed

    Bayliss, Lee E; Culliford, David; Monk, A Paul; Glyn-Jones, Sion; Prieto-Alhambra, Daniel; Judge, Andrew; Cooper, Cyrus; Carr, Andrew J; Arden, Nigel K; Beard, David J; Price, Andrew J

    2017-04-08

    Total joint replacements for end-stage osteoarthritis of the hip and knee are cost-effective and demonstrate significant clinical improvement. However, robust population based lifetime-risk data for implant revision are not available to aid patient decision making, which is a particular problem in young patient groups deciding on best-timing for surgery. We did implant survival analysis on all patients within the Clinical Practice Research Datalink who had undergone total hip replacement or total knee replacement. These data were adjusted for all-cause mortality with data from the Office for National Statistics and used to generate lifetime risks of revision surgery based on increasing age at the time of primary surgery. We identified 63 158 patients who had undergone total hip replacement and 54 276 who had total knee replacement between Jan 1, 1991, and Aug 10, 2011, and followed up these patients to a maximum of 20 years. For total hip replacement, 10-year implant survival rate was 95·6% (95% CI 95·3-95·9) and 20-year rate was 85·0% (83·2-86·6). For total knee replacement, 10-year implant survival rate was 96·1% (95·8-96·4), and 20-year implant survival rate was 89·7% (87·5-91·5). The lifetime risk of requiring revision surgery in patients who had total hip replacement or total knee replacement over the age of 70 years was about 5% with no difference between sexes. For those who had surgery younger than 70 years, however, the lifetime risk of revision increased for younger patients, up to 35% (95% CI 30·9-39·1) for men in their early 50s, with large differences seen between male and female patients (15% lower for women in same age group). The median time to revision for patients who had surgery younger than age 60 was 4·4 years. Our study used novel methodology to investigate and offer new insight into the importance of young age and risk of revision after total hip or knee replacement. Our evidence challenges the increasing trend for more total hip replacements and total knee replacements to be done in the younger patient group, and these data should be offered to patients as part of the shared decision making process. Oxford Musculoskeletal Biomedical Research Unit, National Institute for Health Research. Copyright © 2017 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY license. Published by Elsevier Ltd.. All rights reserved.

  13. A Multicenter Approach Evaluating the Impact of Vitamin E-Blended Polyethylene in Cementless Total Hip Replacement

    PubMed Central

    Jäger, Marcus; van Wasen, Andrea; Warwas, Sebastian; Landgraeber, Stefan; Haversath, Marcel; Group, VITAS

    2014-01-01

    Since polyethylene is one of the most frequently used biomaterials as a liner in total hip arthroplasty, strong efforts have been made to improve design and material properties over the last 50 years. Antioxidants seems to be a promising alternative to further increase durability and reduce polyethylene wear in long term. As of yet, only in vitro results are available. While they are promising, there is yet no clinical evidence that the new material shows these advantages in vivo. To answer the question if vitamin-E enhanced ultra-high molecular weight polyethylene (UHMWPE) is able to improve long-term survivorship of cementless total hip arthroplasty we initiated a randomized long-term multicenter trial. Designed as a superiority study, the oxidation index assessed in retrieval analyses of explanted liners was chosen as primary parameter. Radiographic results (wear rate, osteolysis, radiolucency) and functional outcome (Harris Hip Scores, University of California-Los Angeles, Hip Disability and Osteoarthritis Outcome Score, Visual Analogue Scale) will serve as secondary parameters. Patients with the indication for a cementless total hip arthroplasty will be asked to participate in the study and will be randomized to either receive a standard hip replacement with a highly cross-linked UHMWPE-X liner or a highly cross-linked vitamin-E supplemented UHMWPE-XE liner. The follow-up will be 15 years, with evaluation after 5, 10 and 15 years. The controlled randomized study has been designed to determine if Vitamin-E supplemented highly cross-linked polyethylene liners are superior to standard XLPE liners in cementless total hip arthroplasty. While several studies have been started to evaluate the influence of vitamin-E, most of them evaluate wear rates and functional results. The approach used for this multicenter study, to analyze the oxidation status of retrieved implants, should make it possible to directly evaluate the ageing process and development of the implant material itself over a time period of 15 years. PMID:25002933

  14. Use of a constrained tripolar acetabular liner to treat intraoperative instability and postoperative dislocation after total hip arthroplasty: a review of our experience.

    PubMed

    Callaghan, John J; O'Rourke, Michael R; Goetz, Devon D; Lewallen, David G; Johnston, Richard C; Capello, William N

    2004-12-01

    Constrained acetabular components have been used to treat certain cases of intraoperative instability and postoperative dislocation after total hip arthroplasty. We report our experience with a tripolar constrained component used in these situations since 1988. The outcomes of the cases where this component was used were analyzed for component failure, component loosening, and osteolysis. At average 10-year followup, for cases treated for intraoperative instability (2 cases) or postoperative dislocation (4 cases), the component failure rate was 6% (6 of 101 hips in 5 patients). For cases where the constrained liner was cemented into a fixed cementless acetabular shell, the failure rate was 7% (2 of 31 hips in 2 patients) at 3.9-year average followup. Use of a constrained liner was not associated with an increased osteolysis or aseptic loosening rate. This tripolar constrained acetabular liner provided total hip arthroplasty construct stability in most cases in which it was used for intraoperative instability or postoperative dislocation.

  15. The Bimetric cementless total hip replacement: 7–18 year follow-up assessing the influence of acetabular design on survivorship

    PubMed Central

    Ghassemi, A.; Dorrell, J. H.; Powles, D. P.

    2008-01-01

    The purpose of this study was to evaluate the mid- to long-term survivorship of Bimetric cementless total hip replacement and assess how it is affected by the acetabular design. This was a retrospective analysis of 127 Bimetric cementless total hip replacements in 110 patients with a follow-up of 7–18 years. A single design stem and three different cementless metal-backed acetabular designs were used. Patients were assessed clinically using the Harris hip score and radiologically by independent review of current hip radiographs. There was only one case of aseptic loosening of the femoral stem. The earliest acetabular design showed a high failure rate whilst the latter two designs showed a 96% survivorship at a mean of 9.5 years. We conclude that a combination of the bimetric stem with either of the latter acetabular cup designs has a good mid- to long-term performance. PMID:18551293

  16. Editorial Commentary: Hip Arthroscopy Plays a Role in Painful Hip Resurfacing Arthroplasty but a Prearthroscopy Diagnosis Is Critical to Outcome.

    PubMed

    Rossi, Michael J

    2016-03-01

    Whereas hip arthroscopy plays a role in the investigation and treatment of the painful hip resurfacing arthroplasty, a diagnosis before arthroscopy is critical to improved outcome. The rate of conversion to total hip arthroplasty jumps from 7% to 37% when a pre-arthroscopy diagnosis is not known. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  17. Cost Analysis of Ceramic Heads in Primary Total Hip Arthroplasty.

    PubMed

    Carnes, Keith J; Odum, Susan M; Troyer, Jennifer L; Fehring, Thomas K

    2016-11-02

    The advent of adverse local tissue reactions seen in metal-on-metal bearings, and the recent recognition of trunnionosis, have led many surgeons to recommend ceramic-on-polyethylene articulations for primary total hip arthroplasty. However, to our knowledge, there has been little research that has considered whether the increased cost of ceramic provides enough benefit over cobalt-chromium to justify its use. The primary purpose of this study was to compare the cost-effectiveness of ceramic-on-polyethylene implants and metal-on-polyethylene implants in patients undergoing total hip arthroplasty. Markov decision modeling was used to determine the ceramic-on-polyethylene implant revision rate necessary to be cost-effective compared with the revision rate of metal-on-polyethylene implants across a range of patient ages and implant costs. A different set of Markov models was used to estimate the national cost burden of choosing ceramic-on-polyethylene implants over metal-on-polyethylene implants for primary total hip arthroplasties. The Premier Research Database was used to identify 20,398 patients who in 2012 were ≥45 years of age and underwent a total hip arthroplasty with either a ceramic-on-polyethylene implant or a metal-on-polyethylene implant. The cost-effectiveness of ceramic heads is highly dependent on the cost differential between ceramic and metal femoral heads and the age of the patient. At a cost differential of $325, ceramic-on-polyethylene bearings are cost-effective for patients <85 years of age. At a cost differential of $600, it is cost-effective to utilize ceramic-on-polyethylene bearings in patients <65 years of age, and, at a differential of $1,003, ceramic-on-polyethylene bearings are not cost-effective at any age. The ability to recoup the initial increased expenditure of ceramic heads through a diminished lifetime revision cost is dependent on the price premium for ceramic and the age of the patient. A wholesale switch to ceramic bearings regardless of age or cost differential may result in an economic burden to the health system. Economic and decision analysis, Level III. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  18. Better early functional outcome after short stem total hip arthroplasty? A prospective blinded randomised controlled multicentre trial comparing the Collum Femoris Preserving stem with a Zweymuller straight cementless stem total hip replacement for the treatment of primary osteoarthritis of the hip

    PubMed Central

    van Oldenrijk, Jakob; Scholtes, Vanessa A B; van Beers, Loes W A H; Geerdink, Carel H; Niers, Bob B A M; Runne, Wouter; Bhandari, Mohit; Poolman, Rudolf W

    2017-01-01

    Objectives Primary aim was to compare the functional results at 3 months and 2 years between short and conventional cementless stem total hip arthroplasty (THA). Secondary aim was to determine the feasibility of a double-blind implant-related trial. Design A prospective blinded randomised controlled multicentre trial in patients with osteoarthritis of the hip. All patients, research assistants, clinical assessors, investigators and data analysts were blinded to the type of prosthesis. Population: 150 patients between 18 and 70 years with osteoarthritis of the hip, 75 in the short stem and 75 in the conventional stem group. Mean age: 60 years (SD 7). Interventions: the Collum Femoris Preserving short stem versus the Zweymuller Alloclassic conventional stem. Main outcome measures The Dutch version of the Hip Disability and Osteoarthritis Outcome Score (HOOS). Secondary outcomes measures: Harris Hip Score, the Physical Component Scale of the SF12, the Timed Up and Go test, Pain and the EQ-5D. Feasibility outcomes: continued blinding, protocol adherence and follow-up success rate. Results No significant difference between the two groups. Mean HOOS total score in the short stem group increased 32.7 points from 36.6 (95% CI 32.9 to 40.2) preoperatively to 69.3 (95% CI 66.4 to 72.1) at 3 months follow-up. Mean HOOS total score in the conventional straight stem group increased 36.3 points from 37.1 (95% CI 33.9 to 40.3) preoperatively to 73.4 (95% CI 70.3 to 76.4) at 3 months follow-up. 91.2% of patients remained blinded at 2 years follow-up. Both protocol adherence and follow-up success rate were 98%. Conclusions Functional result at 3 months and 2 years after short stem THA is not superior to conventional cementless THA. There were more perioperative and postoperative complications in the short stem group. Direct comparison of two hip implants in a double-blinded randomised controlled trial is feasible. Trial registration number NTR1560. PMID:29042371

  19. Protective Effect of High Protein and Calcium Intake on the Risk of Hip Fracture in the Framingham Offspring Cohort

    PubMed Central

    Sahni, Shivani; Cupples, L Adrienne; Mclean, Robert R; Tucker, Katherine L; Broe, Kerry E; Kiel, Douglas P; Hannan, Marian T

    2010-01-01

    The effect of protein on bone is controversial, and calcium intake may modify protein's effect on bone. We evaluated associations of energy-adjusted tertiles of protein intake (ie, total, animal, plant, animal/plant ratio) with incident hip fracture and whether total calcium intake modified these associations in the Framingham Offspring Study. A total of 1752 men and 1972 women completed a baseline food frequency questionnaire (1991–1995 or 1995–1998) and were followed for hip fracture until 2005. Hazard ratios (HRs) were estimated using Cox proportional hazards regression adjusting for confounders. Baseline mean age was 55 years (SD 9.9 years, range 26 to 86 years). Forty-four hip fractures occurred over 12 years of follow-up. Owing to significant interaction between protein (total, animal, animal/plant ratio) and calcium intake (p interaction range = .03 to .04), stratified results are presented. Among those with calcium intakes less than 800 mg/day, the highest tertile (T3) of animal protein intake had 2.8 times the risk of hip fracture [HR = 2.84, 95% confidence interval (CI) 1.20–6.74, p = .02] versus the lowest tertile (T1, p trend = .02). In the 800 mg/day or more group, T3 of animal protein had an 85% reduced hip fracture risk (HR = 0.15, 95% CI 0.02–0.92, p = .04) versus T1 (p trend = .04). Total protein intake and the animal/plant ratio were not significantly associated with hip fracture (p range = .12 to .65). Our results from middle-aged men and women show that higher animal protein intake coupled with calcium intake of 800 mg/day or more may protect against hip fracture, whereas the effect appears reversed for those with lower calcium intake. Calcium intake modifies the association of protein intake and the risk of hip fracture in this cohort and may explain the lack of concordance seen in previous studies. © 2010 American Society for Bone and Mineral Research. PMID:20662074

  20. /sup 99m/Tc-methylene diphosphonate bone imaging in the evaluation of total hip prostheses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weiss, P.E.; Mall, J.C.; Hoffer, P.B.

    1979-12-01

    A retrospective study was performed to determine the accuracy of /sup 99m/Tc-methylene diphosphonate bone imaging in the evaluation of total hip arthroplasty for loosening and/or infection. Using focally increased activity at the tip of the femoral component or in the region of the acetabular component as a criterion, the examination was 77% specific and 100% sensitive for loosening and/or infection. A possible explanation for the increased uptake at the tip of the femoral component and the role of this examination in the management of a painful total hip prosthesis are discussed.

  1. Hemorrhagic iliopsoas bursitis complicating well-functioning ceramic-on-ceramic total hip arthroplasty.

    PubMed

    Park, Kyung Soon; Diwanji, Sanket R; Kim, Hyung Keun; Song, Eun Kyoo; Yoon, Taek Rim

    2009-08-01

    Iliopsoas bursitis has been increasingly recognized as a complication of total hip arthroplasty and is usually associated with polyethylene wear. Here, the authors report a case of hemorrhagic iliopsoas bursitis complicating an otherwise well-functioning ceramic-on-ceramic arthroplasty performed by minimal invasive modified 2-incision technique. The bursitis in turn resulted in femoral nerve palsy and femoral vein compression. In this report, there was no evidence to support that the bursitis was due to an inflammatory response to ceramic wear particles or any other wear particles originating from the total hip arthroplasty.

  2. [A therapeutic effect analysis of femur first principle and combined anteversion technique during total hip arthroplasty].

    PubMed

    Wang, X Q; Wu, C S; Sun, S; Wang, J; Li, W; Zhang, W

    2018-04-01

    Objective: To investigate the situation of hip dislocation with the application of "femur first" principle and "combined anteversion technique" during total hip arthroplasty. Methods: A retrospective analysis has been done on the clinical data about 104 patients(133 hips)who were diagnosed as hip disease and were treated with total hip arthroplasty by the doctors from the Department of Joint Orthorpaedics of Shandong Provincial Hospital Affiliated to Shandong University from June 2014 to June 2016, and all the prostheses applied in the operation were cementless ones.Among them, 65 patients were males, 39 females and their age was 46.6 years (ranging from 23 to 76 years) .And 29 of them underwent bilateral hip operations and 75 unilateral ones.Seventy-six cases of aseptic necrosis of the femoral head in the terminal stage, 28 cases of hip dysplasia and osteoarthritis.Surgical approach: of all the operations, 103 hips were operated on with hardinge approach, 30 with posterolateral approach.During the operation, first of all, the femoral medullary cavity was broached and then the anteversion of intramedullary broacher was measured.After that, the anteversion of the acetabular cup was calculated as 37° minus the anteversion of the broacher, and the acetabular cup was implanted at that angle.The patients' prosthesis combined anteversion, range of motion of the hip joint, operation time, hemorrhage amount, and complications had been kept record.One, three, and six months respectively after the operation, all the patients received outpatient review, and took anteroposterior and lateral position X-ray examination.Harris hip score had been applied to evaluate their hip function before the operation and six months after the operation. Results: All the patients had been operated on smoothly, with the operation time of(57.6±14.5)minutes(36-115 minutes)and hemorrhage amount of (336.5±50.8)ml(180-620 ml). The operation finding showed that the combined anteversion by employing"femur first"principle and combined anteversion techniqueis was (36.6±6.8)°. Also, range of motion of the patients' hip conforms to the D'Lima criterion and no patients had experienced dislocation and some other serious complications.The follow-up ended at August 2017, which lasted for 12.2 months(6-18 months), and 88 cases(119 hips) were interviewed. The Harris hip score for the affected sides of the hip joints 6 months after the surgery was 94.6(86-100). Compared with the score of 29.8(12-43) before surgery, the t -test had proven its statistical significance( t =12.82, P =0.003). Conclusion: Based upon the "femoral first" principle and "combined anteversion technique" during total hip arthroplasty, these operations has been carried out well enough to meet the patients' needs of performing normal daily activities.

  3. Expect the best, prepare for the worst: surgeon and patient expectation of the outcome of primary total hip and knee replacement.

    PubMed Central

    Moran, M.; Khan, A.; Sochart, D. H.; Andrew, G.

    2003-01-01

    A cross-sectional study of 100 surgeons and 370 patients awaiting primary total hip or knee replacement was carried out. Oxford hip or knee score questionnaires were sent to the surgeons and patients. They were asked to predict the level of symptoms expected 6 months following surgery. The Oxford scores derive a value of 12-60, with a greater score indicating worsening symptoms. The mean pre-operative score was 45.12 for the hip patients and 42.96 for the knee patients, and the patients expected this to drop to 23.70 and 25.66, respectively, 6 months' postoperatively. This was a significant difference for both groups. The surgeons expected the patients to have a mean postoperative score of 20.91 for the hip group and 22.19 for the knee group. The surgeons' scores were significantly lower than those from the patients. There was a significant difference between the patients' and surgeons' expectations of the results of total knee and hip replacement surgery. The surgeons expected better results than the patients. We believe that this is the first study that directly compares surgeon and patient expectations of lower limb arthroplasty. PMID:12831497

  4. A Randomised Multi-centre Study to Compare the Long-term Performance of the Future Hip to 3 Other Implants in Primary Total Hip Replacement

    ClinicalTrials.gov

    2016-10-06

    Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis; Perthes Disease

  5. IMU-based Real-time Pose Measurement system for Anterior Pelvic Plane in Total Hip Replacement Surgeries.

    PubMed

    Zhe Cao; Shaojie Su; Hao Tang; Yixin Zhou; Zhihua Wang; Hong Chen

    2017-07-01

    With the aging of population, the number of Total Hip Replacement Surgeries (THR) increased year by year. In THR, inaccurate position of the implanted prosthesis may lead to the failure of the operation. In order to reduce the failure rate and acquire the real-time pose of Anterior Pelvic Plane (APP), we propose a measurement system in this paper. The measurement system includes two parts: Initial Pose Measurement Instrument (IPMI) and Real-time Pose Measurement Instrument (RPMI). IPMI is used to acquire the initial pose of the APP, and RPMI is used to estimate the real-time pose of the APP. Both are composed of an Inertial Measurement Unit (IMU) and magnetometer sensors. To estimate the attitude of the measurement system, the Extended Kalman Filter (EKF) is adopted in this paper. The real-time pose of the APP could be acquired together with the algorithm designed in the paper. The experiment results show that the Root Mean Square Error (RMSE) is within 1.6 degrees, which meets the requirement of THR operations.

  6. Impact of a learning curve on the survivorship of 4802 cementless total hip arthroplasties.

    PubMed

    Magill, P; Blaney, J; Hill, J C; Bonnin, M P; Beverland, D E

    2016-12-01

    Our aim was to report survivorship data and lessons learned with the Corail/Pinnacle cementless total hip arthroplasty (THA) system. Between August 2005 and March 2015, a total of 4802 primary cementless Corail/Pinnacle THAs were performed in 4309 patients. In March 2016, we reviewed these hips from a prospectively maintained database. A total of 80 hips (1.67%) have been revised which is equivalent to a cumulative risk of revision of 2.5% at ten years. The rate of revision was not significantly higher in patients aged ≥ 70 years (p = 0.93). The leading indications for revision were instability (n = 22, 0.46%), infection (n = 20, 0.42%), aseptic femoral loosening (n = 15, 0.31%) and femoral fracture (n = 6, 0.12%). There were changes in the surgical technique with respect to the Corail femoral component during the ten-year period involving a change to collared components and a trend towards larger size. These resulted in a decrease in the rate of iatrogenic femoral fracture and a decrease in the rate of aseptic loosening. The rate of revision in this series is comparable with the best performing THAs in registry data. Most revisions were not directly related to the implants. Despite extensive previous experience with cemented femoral components, the senior author noted a learning curve requiring increased focus on primary stability. The number of revisions related to the femoral component is reducing. Any new technology has a learning curve that may be independent of surgical experience. Cite this article: Bone Joint J 2016;98-B:1589-96. ©2016 The British Editorial Society of Bone & Joint Surgery.

  7. Single-Anesthetic Versus Staged Bilateral Total Hip Arthroplasty: A Matched Cohort Study.

    PubMed

    Houdek, Matthew T; Wyles, Cody C; Watts, Chad D; Wagner, Eric R; Sierra, Rafael J; Trousdale, Robert T; Taunton, Michael J

    2017-01-04

    There is debate regarding the role of single-anesthetic versus staged bilateral total hip arthroplasty (THA) for patients with end-stage bilateral osteoarthritis. Studies have shown that single-anesthetic bilateral THA is associated with systemic complications, but there are limited data comparing patient outcomes in a matched setting of bilateral THA. We identified 94 patients (188 hips) who underwent single-anesthetic bilateral THA. Fifty-seven percent of the patients were male. Patients had a mean age of 52.2 years and body mass index of 27.1 kg/m. They were matched 1:1 on the basis of sex, age (±1 year), and year of surgery (±3 years) to a cohort of patients undergoing staged bilateral THA. In the staged group, there was <1 year between procedures (range, 5 days to 10 months). Mean follow-up was 4 years for each group. Patients in the single-anesthetic group experienced shorter total operating room time and length of stay. There was no difference (hazard ratio [HR] = 0.73, p = 0.50) in the overall revision-free survival in patients undergoing single-anesthetic or staged bilateral THA. The risks of reoperation (HR = 0.69, p = 0.40), complications (HR = 0.83, p = 0.48), and mortality (HR = 0.47, p = 0.10) were similar. Single-anesthetic bilateral THA reduced the total cost of care (by 27%, p = 0.0001). In this matched cohort analysis, single-anesthetic bilateral THA was not associated with an increased risk of revision, reoperation, or postoperative complications, while decreasing cost. In our experience, single-anesthetic bilateral THA is a safe procedure that, for certain patients, offers an excellent means to deal with bilateral hip osteoarthritis. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  8. Estimating prevalence of osteoporosis: examples from industrialized countries.

    PubMed

    Wade, S W; Strader, C; Fitzpatrick, L A; Anthony, M S; O'Malley, C D

    2014-01-01

    In nine industrialized countries in North America, Europe, Japan, and Australia, country-specific osteoporosis prevalence (estimated from published data) at the total hip or hip/spine ranged from 9 to 38 % for women and 1 to 8 % for men. In these countries, osteoporosis affects up to 49 million individuals. Standardized country-specific prevalence estimates are scarce, limiting our ability to anticipate the potential global impact of osteoporosis. This study estimated the prevalence of osteoporosis in several industrialized countries (USA, Canada, five European countries, Australia, and Japan) using the World Health Organization (WHO) bone mineral density (BMD)-based definition of osteoporosis: BMD T-score assessed by dual-energy x-ray absorptiometry ≤-2.5. Osteoporosis prevalence was estimated for males and females aged 50 years and above using total hip BMD and then either total hip or spine BMD. We compiled published location-specific data, using the National Health and Nutrition Examination Survey (NHANES) III age and BMD reference groups, and adjusted for differences in disease definitions across sources. Relevant NHANES III ratios (e.g., male to female osteoporosis at the total hip) were applied where data were missing for countries outside the USA. Data were extrapolated from geographically similar countries as needed. Population counts for 2010 were used to estimate the number of individuals with osteoporosis in each country. For females, osteoporosis prevalence ranged from 9 % (UK) to 15 % (France and Germany) based on total hip BMD and from 16 % (USA) to 38 % (Japan) when spine BMD data were included. For males, prevalence ranged from 1 % (UK) to 4 % (Japan) based on total hip BMD and from 3 % (Canada) to 8 % (France, Germany, Italy, and Spain) when spine BMD data were included. Up to 49 million individuals met the WHO osteoporosis criteria in a number of industrialized countries in North America, Europe, Japan, and Australia.

  9. Impact of the Holocaust on the Rehabilitation Outcome of Older Patients Sustaining a Hip Fracture.

    PubMed

    Mizrahi, Eliyahu H; Lubart, Emilia; Heymann, Anthony; Leibovitz, Arthur

    2017-04-01

    Holocaust survivors report a much higher prevalence of osteoporosis and fracture in the hip joint compared to those who were not Holocaust survivors. To evaluate whether being a Holocaust survivor could affect the functional outcome of hip fracture in patients 64 years of age and older undergoing rehabilitation. A retrospective cohort study compromising 140 consecutive hip fracture patients was conducted in a geriatric and rehabilitation department of a university-affiliated hospital. Being a Holocaust survivor was based on registry data. Functional outcome was assessed by the Functional Independence Measure (FIM)TM at admission and discharge from the rehabilitation ward. Data were analyzed by t-test, chi-square test, and linear regression analysis. Total and motor FIM scores at admission (P = 0.004 and P = 0.006, respectively) and total and motor FIM gain scores at discharge (P = 0.008 and P = 0.004 respectively) were significantly higher in non-Holocaust survivors compared with Holocaust survivors. A linear regression analysis showed that being a Holocaust survivor was predictive of lower total FIM scores at discharge (β = -0.17, P = 0.004). Hip fracture in Holocaust survivors showed lower total, motor FIM and gain scores at discharge compared to non-Holocaust survivor patients. These results suggest that being a Holocaust survivor could adversely affect the rehabilitation outcome following fracture of the hip and internal fixation.

  10. Endoscopic resection of acetabular screw tip to decompress sciatic nerve following total hip arthroplasty.

    PubMed

    Yoon, Sun-Jung; Park, Myung-Sik; Matsuda, Dean K; Choi, Yun Ho

    2018-06-04

    Sciatic nerve injuries following total hip arthroplasty are disabling complications. Although degrees of injury are variable from neuropraxia to neurotmesis, mechanical irritation of sciatic nerve might be occurred by protruding hardware. This case shows endoscopic decompression for protruded acetabular screw irritating sciatic nerve, the techniques described herein may permit broader arthroscopic/endoscopic applications for management of complications after reconstructive hip surgery. An 80-year-old man complained of severe pain and paresthesias following acetabular component revision surgery. Physical findings included right buttock pain with radiating pain to lower extremity. Radiographs and computed tomography imaging showed that the sharp end of protruded screw invaded greater sciatic foramen anterior to posterior and distal to proximal direction at sciatic notch level. A protruding tip of the acetabular screw at the sciatic notch was decompressed by use of techniques gained from experience performing endoscopic sciatic nerve decompression. The pre-operative pain and paresthesias resolved post-operatively after recovering from anesthesia. This case report describes the first documented endoscopic resection of the tip of the acetabular screw irritating sciatic nerve after total hip arthroplasty. If endoscopic resection of an offending acetabular screw can be performed in a safe and minimally invasive manner, one can envision a future expansion of the role of hip arthroscopic surgery in several complications management after total hip arthroplasty.

  11. Effects of health intervention program on cardiometabolic risk profiles from health evaluation center in Asian population: a longitudinal study and propensity analysis.

    PubMed

    Liu, Chuan-Chuan; Hung, Chung-Lieh; Shih, Shou-Chuan; Ko, Hung-Ju; Chang, Ray-E

    2015-08-20

    Health intervention program (HIP) based on diet and lifestyle modifications had been shown to improve cardiovascular risks. The effects of such program on a variety of cardiometabolic outcome measures conducted in a strict analysis remained relatively unexplored. A total of 2,660 participants (mean age: 43.3 ± 10 years, 63.6% male) underwent annual health survey from our health evaluation department. We implemented health intervention program (HIP) in which diet and lifestyle modifications including smoking cessation and advised physical activities were introduced. We further studied the effects of HIP on several cardiometabolic outcome measures including Framingham, metabolic scores and renal function in terms of Egfr with a mean follow-up period of 38.5 months. Propensity score (PS) matching (HIP vs non-HIP group) was used to avoid effects of case selection bias. Totally 1,004 (502 subjects for each group) left after PS matching protocol (both HIP and non-HIP group). The HIP group showed significant decline of waist circumference (-1.46 ± 0.61, p = 0.016), post-prandial glucose (-6.77 ± 2.06, p = 0.001), and total cholesterol level (-4.42 ± 2.15, p = 0.04), with borderline increase in eGFR (1.72 ± 0.94, p = 0.068) after an average of 1.91 ± 1.14 year follow up period. Exercise behavior significantly increased for those who received HIP when compared to the non-HIP group (44.6 vs 52.4 %, p = 0.014). PS matching and difference-in-difference (DID) analysis further confirmed the beneficial effects of ATP III reduction by HIP (-0.36 ± 0.06, p < 0.05). We demonstrated in our study that several cardiometabolic profiles can be substantially improved after health intervention introduction at the health evaluation center, supporting the beneficial evidence of such health intervention programs implementation based on primary prevention view points.

  12. [Results and experiences of conversion of hip arthrodesis ].

    PubMed

    Schuh, A; Zeiler, G; Werber, S

    2005-03-01

    With the predictably good outcome of total hip arthroplasty today (THA), hip arthrodesis currently has limited indications. Over the long term, however, most patients develop secondary degenerative arthritis in the spine, contralateral hip, and ipsilateral knee due to overloading. The deteriorating condition of these joints eventually causes the onset of pain, which often requires conversion of a fused hip to a THA. The results and experiences of conversions of a hip arthrodesis into a THA are reported. Between 1 January 1985 and 31 December 2001 conversion of a previously performed arthrodesis of the hip to THA was carried out in a total of 45 patients; 34 patients could be followed up after the conversion to THA after a mean of 77.5 months (min.: 24, max.: 208). The primary indications for the conversion were low back pain (n=21) and ipsilateral knee pain (n=13). The mean age at the time of THA was 75.3 years (min.: 32, max.: 74). The mean time interval between the arthrodesis and the conversion to THA was 30.4 years (min.: 5, max.: 66). Of 34 hips, 29 (85%) were either pain free or had minimal pain. Complications included one persisting sciatic nerve palsy, two superficial infections, two periprosthetic fractures, and two heterotopic ossifications IV degrees with one recurrence of ankylosis and one marked reduction of motion. Revision arthroplasty was performed in four hips. Postoperatively 7 patients showed no limping, 11 showed a slight limp, and 17 a pronounced limp. Recurrent dislocations occurred in one patient. We conclude that this operation can lead to satisfactory results even after a long duration of the arthrodesis. There is a high rate of complications after conversion of a hip arthrodesis to a total hip arthroplasty. These issues must be carefully considered and discussed with the patient before any conversion procedure.

  13. Recovery of walking speed and symmetrical movement of the pelvis and lower extremity joints after unilateral THA.

    PubMed

    Miki, Hidenobu; Sugano, Nobuhiko; Hagio, Keisuke; Nishii, Takashi; Kawakami, Hideo; Kakimoto, Akihiro; Nakamura, Nobuo; Yoshikawa, Hideki

    2004-04-01

    In 17 patients with unilateral hip disease who underwent total hip arthroplasty (THA), the gait was analyzed preoperatively and 1, 3, 6, and 12 months after unilateral THA using a Vicon system to assess the recovery of walking speed and symmetrical movement of the hip, knee, ankle, and pelvis. The walking speed of these patients reached that of normal Japanese persons by 12 months after surgery. Walking speed was correlated with the range of hip motion on the operated side at 1 month postoperatively, and was correlated with the hip joint extension moment of force on both sides from 3 to 6 months after surgery. Before THA, asymmetry was observed in the range of the hip motion, maximum hip flexion, maximum hip extension, maximum knee flexion, as well as in pelvic obliquity, pelvic tilt, and pelvic rotation. There were no differences of the stride length or step length between both sides throughout the observation period. The preoperative range of hip flexion on the operated side during a gait cycle (21.3+/-7.9 degrees ) was significantly smaller than on the non-operated side (46.7+/-7.1 degrees ), and the difference between sides was still significant at 12 months after surgery (35.1+/-6.2 degrees on the operated side and 43.6+/-5.7 degrees on the non-operated side). The majority (74%) of the difference in hip motion range during this period was due to the difference in maximum extension of the hip. The increase in the range of pelvic tilt and the range of motion of the opposite hip showed an inverse correlation with the range of motion of the operated hip, suggesting a compensatory preoperative role. However, this correlation became insignificant after 6 months postoperatively. Asymmetry of the range of hip motion persisted at 12 months after THA in patients with unilateral coxoarthropathy during free level walking, while the operation normalized the spatial asymmetry of other joints and the walking speed prior to the recovery of hip motion.

  14. Pseudotumor Caused by Titanium Particles From a Total Hip Prosthesis.

    PubMed

    Sakamoto, Masaaki; Watanabe, Hitoshi; Higashi, Hidetaka; Kubosawa, Hitoshi

    2016-01-01

    A 77-year-old woman underwent metal-on-polyethylene total hip arthroplasty for osteoarthritis of the right hip at another institution. During surgery, the greater trochanter was broken and internal fixation was performed with a trochanteric cable grip reattachment. Although postoperative recovery was uneventful, approximately 6 years later, the patient had severe right hip pain with apparent swelling, and she was referred to the authors' institution. Plain radiographs showed evidence of severe osteolysis in the proximal femur and cable breakage; however, preoperative aspiration culture findings were negative for bacterial growth. Magnetic resonance imaging showed a well-circumscribed mass, presumed to be a pseudotumor. Serum cobalt and chromium levels were within normal limits, and the serum titanium level was high. During surgery, the mass was excised and removal of the cable system revealed a sharp deficit in the bare femoral stem. Gross surgical findings showed no obvious evidence of infection and no corrosion at the head-neck junction; therefore, all components were retained besides the cable system, which resulted in clinical recovery. All of the cultures from specimens were negative for bacterial growth, and histologic findings were compatible with a pseudotumor, such as histiocytes containing metal particles, abundant plasma cells, and CD8-positive cells. Quantitative analysis by inductively coupled plasma atomic emission spectrometry showed that the main source of metal debris in the pseudotumor was the femoral stem, which was made of titanium alloy, not the broken cable, which was made of cobalt-chromium alloy. The findings suggest that titanium particles can form symptomatic solid pseudotumors. Copyright 2016, SLACK Incorporated.

  15. Outcome after cementless total hip arthroplasty for arthritic hip in patients with residual poliomyelitis: a case series.

    PubMed

    Cho, Yoon J; Lee, Choong H; Chun, Young S; Rhyu, Kee H

    2016-09-29

    In this case series, we investigated the outcome of cementless total hip arthroplasty (THA) for advanced hip osteoarthritis in patients with residual poliomyelitis to evaluate its clinical usefulness for these patients. 11 unilateral cementless primary THA were performed to arthritic hips in patients with residual poliomyelitis. 7 were in paralytic and 4 were in nonparalytic limbs. The mean follow-up duration was 79.9 months. Retrospective clinical evaluations with various scores and radiological evaluations were made. Harris Hip Score, Western Ontario and McMaster Universities Arthritis Index (WOMAC) and Short-form (SF)-36 physical scales were significantly improved after the surgery. However, UCLA activity score and SF-36 mental scale were not. Because of remaining leg length discrepancies, all but 1 noted a residual limp. In nonparalytic hip, functional acetabular cup inclination during weight bearing significantly increased from installed inclination. Other than 1 case of posterior dislocation, no complications were observed. Although the overall result itself is excellent, THA for these patients cannot improve limp, physical activity and mental status. Surgeons should be aware of the change of the inclination of acetabular cup during mobilisation, especially for THA in contralateral hip.

  16. Hip Replacement - Multiple Languages

    MedlinePlus

    ... Hip Replacement - العربية (Arabic) Bilingual PDF Health Information Translations Chinese, Simplified (Mandarin dialect) (简体中文) Expand Section Total ... Chinese, Simplified (Mandarin dialect)) Bilingual PDF Health Information Translations Chinese, Traditional (Cantonese dialect) (繁體中文) Expand Section Total ...

  17. Preventative Therapeutics for Heterotopic Ossification

    DTIC Science & Technology

    2015-10-01

    in the general population undergoing invasive surgeries such as total hip arthroplasty . There is also a congenital form of it that can affect...insults and can also occur in patients undergoing invasive surgeries, including total hip arthroplasty (6). HO is very common in our wounded service

  18. A comparison between patient recall and concurrent measurement of preoperative quality of life outcome in total hip arthroplasty.

    PubMed

    Howell, Jonathan; Xu, Min; Duncan, Clive P; Masri, Bassam A; Garbuz, Donald S

    2008-09-01

    The objective is to evaluate the reliability of patients' recall of preoperative pain and function during the immediate postoperation period after total hip arthroplasty. A prospective cohort of 104 patients completed a survey about their quality of life before operation, and recalled preoperative status at 3 days, 6 weeks, and 12 weeks after operation. Quality of life was measured by the Western Ontario and McMaster University Osteoarthritis Index, the Oxford-12 hip score, and the 12-item Short-Form score. The intraclass correlation coefficient and Spearman correlation coefficient were used to compare preoperative quality of life scores to the scores recalled. The reliability of recall remained high up to 3 months postoperation. Patients are able to accurately recall their preoperative function for up to 3 months after total hip arthroplasty.

  19. High prevalence of noise following Delta ceramic-on-ceramic total hip arthroplasty.

    PubMed

    Salo, P P; Honkanen, P B; Ivanova, I; Reito, A; Pajamäki, J; Eskelinen, A

    2017-01-01

    We evaluated the short-term functional outcome and prevalence of bearing-specific generation of audible noise in 301 patients (336 hips) operated on with fourth generation (Delta) medium diameter head, ceramic-on-ceramic (CoC) total hip arthroplasties (THAs). There were 191 female (63%) and 110 male patients (37%) with a mean age of 61 years (29 to 78) and mean follow-up of 2.1 years (1.3 to 3.4). Patients completed three questionnaires: Oxford Hip Score (OHS), Research and Development 36-item health survey (RAND-36) and a noise-specific symptom questionnaire. Plain radiographs were also analysed. A total of three hips (0.9%) were revised. There were 52 patients (54 hips, 17%) who reported noise, and in 25 (48%) of them the noise was frequently heard. In the multiple regression analysis, the only independent risk factor for noise was a specific THA brand, with a threefold increased risk (95% confidence intervals 1.39 to 6.45, p = 0.005) of noise compared with the reference THA brand. Patients with noisy hips had lower median OHS (43 versus 46.5, p = 0.002) and their physical functioning (p = 0.021) subscale in RAND-36 was reduced. Noise was surprisingly common in this population. Cite this article: Bone Joint J 2017;99-B:44-50. ©2017 The British Editorial Society of Bone & Joint Surgery.

  20. Comparison of Blood Loss After Total Hip Arthroplasty Between Ankylosing Spondylitis and Osteoarthritis.

    PubMed

    Li, Jia; Zhao, Jinzhu; He, Chongru; Tong, Wenwen; Zou, Yuming; Xu, Weidong

    2016-07-01

    This study was conducted to compare the blood loss during primary total hip arthroplasty (THA) between ankylosing spondylitis (AS) and hip osteoarthritis (OA). We reviewed 120 THAs in 68 patients comprising 3 groups: AS with total bony ankylosis of the hips (ASB), AS with stiff hips (ASS), and OA. Demographics, perioperative laboratory values, intraoperative data, blood loss, transfusion rate, transfusion reactions, surgical complications, hospitalization cost, and length of stay (LOS) were collected and analyzed among ASB, ASS, and OA groups. The patients of the ASB and ASS groups were much younger and thinner than those of the OA group. There were no significant differences in the preoperative values of activated partial thromboplastin time, prothrombin time, and international normalized ratio among the 3 groups (all P > .05). The intraoperative blood loss, volume of drainage, hidden blood loss, transfusion rate, transfusion reactions, and hospitalization cost in the ASB group were significantly higher than in the other 2 groups, although not significantly different between the ASS and OA groups (P > .05). Both AS and OA can cause hyperosteogeny to the hips, but ASB patients have more serious symptoms in their affected hips. This may cause more blood loss in THA surgery because of bone surface bleeding. The reason that ASB patients suffered more blood loss may be related to the high difficulty and long duration of the operation. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Extensive Surgical Wound Lavage Reduces the Incidence and Severity of Heterotopic Ossification in Primary Total Hip Replacement: A Study of 175 Hip Replacements.

    PubMed

    Kantak, Avadhoot P; Shah, Nirav N

    2017-12-01

    One of the local factors contributing to the formation of heterotopic ossification includes bone debris generated during the surgery. This risk can be partially nullified by use of saline wash. Our research aim was to ascertain if extensive intraoperative lavage can reduce the incidence and severity of heterotopic ossification in primary total hip arthroplasty. A retrospective case control radiological study of 145 patients (175 hip replacements). The control group received minimal intra-operative lavage (<1,000 mL); consisted of 90 primary hip replacements. The index group received extensive saline lavage (>3,000 mL), and included 85 primary hip replacements. Brooker classification was used to grade radiographs at one year for development of heterotopic ossification. Sixty-six patients in control group had heterotopic ossification, with six showing a significant grade (grade 3 or 4). Thirty-five patients in the index group had heterotopic ossification with no incidence of severe grade. Majority patients in the index group showed a predominantly grade 1 heterotopic ossification; 28 out of 35, as compared to 37 out of 66 in control group. There was a statistically significant difference in the incidence ( P <0.05) as well as severity of heterotopic ossification between the groups ( P <0.05). We conclude that use of extensive lavage during total hip replacement reduces the incidence as well as severity of heterotopic ossification.

  2. [Efficacy of health education on patients with hip replacement based on the Internet].

    PubMed

    Zhou, Yang; Yang, Tubao; Li, Yinglan; Yu, Jie; Zeng, Biyun

    2015-03-01

    To evaluate the efficacy of health education on patients with hip replacement based on the Internet, and to establish a new health education model through modern technology. A total of 300 patients with hip replacement from March to August, 2015 were enrolled in this study. The participants were divided into a control group and an experimental group according to months surgeries performed. Traditional education was applied in the control group while the multimedia source material plus the Internet platform of Joint Registration System were applied in the experimental group. Levels of anxiety, degree of satisfaction, and postoperative complications were analyzed. The levels of knowledge, attitude and behavior compliance in the patients of the experimental group were significantly improved, while the levels of postoperative anxiety were decreased compared with those in the control group (P<0.05). Education based on the Internet platform of Joint Registration System and the computer video could improve patients' knowledge, attitude, and behavior, which is worthy of clinical spread.

  3. Matched cohort study of topical tranexamic acid in cementless primary total hip replacement.

    PubMed

    Sanz-Reig, Javier; Mas Martinez, Jesus; Verdu Román, Carmen; Morales Santias, Manuel; Martínez Gimenez, Enrique; Bustamante Suarez de Puga, David

    2018-03-29

    Tranexamic acid has been shown to be effective in reducing blood loss after total hip replacement. The purpose of this study was to prospectively assess the effectiveness of topical TXA use to reduce blood loss after primary total hip replacement and to compare these outcomes with those of a matched control group from a similar cohort that did not have received tranexamic acid. This is a prospective matched control study to assess the effect of a 2 g topical tranexamic acid in 50 mL physiological saline solution in total hip replacement. Primary outcomes were hemoglobin and hematocrit drop, and total blood loss. Secondary outcomes were transfusion rates, length of hospital stay, deep vein thrombosis, and pulmonary embolism events. We could match 100 patients to a control group. There were no statistical significantly differences between the two groups. The hemoglobin and hematocrit postoperative values were significantly higher in topical tranexamic acid group than in control group (P < 0.001). The mean total blood loss was 769 in topical tranexamic acid group and 1163 in control group with significant differences (P = 0.001), which meant 34% reduction in total blood loss. Length of stay was lower in topical tranexamic acid group. The risk of deep vein thrombosis and pulmonary events did not increase. A single dose of 2 g tranexamic acid in 50 mL physiological saline solution topical administration was effective and safe in reducing bleeding in patients undergoing unilateral primary non-cemented total hip replacement compared to a matched control group.

  4. MRI Evaluation of Post Core Decompression Changes in Avascular Necrosis of Hip.

    PubMed

    Nori, Madhavi; Marupaka, Sravan Kumar; Alluri, Swathi; Md, Naseeruddin; Irfan, Kazi Amir; Jampala, Venkateshwarlu; Apsingi, Sunil; Eachempati, Krishna Kiran

    2015-12-01

    Avascular necrosis of hip typically presents in young patients. Core decompression in precollapse stage provides pain relief and preservation of femoral head. The results of core decompression vary considerably despite early diagnosis. The role of MRI in monitoring patients post surgically has not been clearly defined. To study pre and post core decompression MRI changes in avascular necrosis of hip. This is a contiguous observational cohort of 40 hips treated by core decompression for precollapse avascular necrosis of femoral head, who had a baseline MRI performed before surgery. Core decompression of the femoral head was performed within 4 weeks. Follow up radiograph and MRI scans were done at six months. Harris hip score preoperatively, 1 month and 6 months after the surgery was noted. Success in this study was defined as postoperative increase in Harris hip score (HHS) by 20 points and no additional femoral collapse. End point of clinical adverse outcome as defined by fall in Harris hip score was conversion or intention to convert to total hip replacement (THR). MRI parameters in the follow up scan were compared to the preoperative MRI. Effect of core decompression on bone marrow oedema and femoral head collapse was noted. Results were analysed using SPSS software version. Harris hip score improved from 57 to 80 in all patients initially. Six hips had a fall in Harris hip score to mean value of 34.1 during follow up (9 to 12 months) and underwent total hip replacement. MRI predictors of positive outcome are lesions with grade A extent, Grade A & B location. Bone marrow oedema with lesions less than 50% involvement, medial and central location. Careful selection of patients by MR criteria for core decompression provides satisfactory outcome in precollapse stage of avascular necrosis of hip.

  5. Outcomes of a metal-on-metal total hip replacement system.

    PubMed

    Matharu, G S; Theivendran, K; Pynsent, P B; Jeys, L; Pearson, A M; Dunlop, D J

    2014-10-01

    High short-term failure rates have been reported for a variety of metal-on-metal (MoM) total hip replacements (THRs) owing to adverse reactions to metal debris (ARMD). This has led to the withdrawal of certain poorly performing THRs. This study analysed the outcomes of a MoM THR system. Between 2004 and 2010, 578 uncemented MoM THRs (511 patients, mean age: 60.0 years) were implanted at one specialist centre. The THR system used consisted of the Corail(®) stem, Pinnacle(®) cup, Ultamet(®) liner and Articul/eze(®) femoral head (all DePuy, Leeds, UK). All patients were recalled for clinical review with imaging performed as necessary. The mean follow-up duration was 5.0 years (range: 1.0-9.1 years). Overall, 39 hips (6.7%) in 38 patients (all 36 mm femoral head size) underwent revision at a mean time of 3.5 years (range: 0.01-8.3 years) from the index THR with 30 revisions (77%) performed in women. The cumulative eight-year survival rate for all THRs was 88.9% (95% confidence interval [CI]: 78.5-93.4%), with no difference (p=0.053) between male (95.2%, 95% CI: 84.2-98.7%) and female patients (85.3%, 95% CI: 70.2-92.1%) at eight years. Seventeen revisions (44%) were performed for ARMD. There was no significant difference in absolute postoperative Oxford hip scores between men and women (p=0.608). The mean acetabular inclination in unrevised THRs was 44.0°. Forty-seven non-revised THRs (8.7%) had blood metal ion concentrations above recommended thresholds (seven had periprosthetic effusions). Although this MoM THR system has not failed as dramatically as other similar designs, we recommend against continued use and advise regular clinical surveillance to identify ARMD early.

  6. Minimum ten-year results of primary bipolar hip arthroplasty for degenerative arthritis of the hip.

    PubMed

    Pellegrini, Vincent D; Heiges, Bradley A; Bixler, Brian; Lehman, Erik B; Davis, Charles M

    2006-08-01

    Bipolar hip arthroplasty has been advocated by some as an alternative to total hip arthroplasty for the treatment of degenerative arthritis of the hip. We sought to assess the results of this procedure at our institution after a minimum duration of follow-up of ten years. We retrospectively reviewed a consecutive series of 152 patients (173 hips) who underwent primary bipolar hemiarthroplasty for the treatment of symptomatic degenerative arthritis of the hip with a cementless femoral component between 1983 and 1987. Of the original cohort of 152 patients, ninety-two patients (104 hips) were available for clinical and radiographic review at a mean of 12.2 years postoperatively. At the time of the latest follow-up, self-administered Harris hip questionnaires were used to assess pain, mobility, activity level, and overall satisfaction with the procedure. Biplanar hip radiographs were made to evaluate bipolar shell migration, osteolysis, and femoral stem fixation. At the time of the latest follow-up, nineteen patients (nineteen hips) had undergone revision to total hip arthroplasty because of mechanical failure, and three patients (three hips) were awaiting revision because of symptomatic radiographic mechanical failure. Twelve acetabular revisions were performed or scheduled for the treatment of pelvic osteolysis or protrusio acetabuli secondary to component migration. Acetabular reconstruction required bone-grafting, an oversized shell, and/or a pelvic reconstruction ring. The overall rate of mechanical failure was 21.2% (twenty-two of 104 hips), with 91% (twenty) of the twenty-two failures involving the acetabular component. Reaming of the acetabulum at the time of the index arthroplasty was associated with a 6.4-fold greater risk of revision. The rate of implant survival, with revision because of mechanical failure as the end point, was 94.2% for femoral components and 80.8% for acetabular components at a mean of 12.2 years. Of the remaining sixty-nine patients (eighty-one hips) in whom the original prosthesis was retained, seventeen patients (24.6%) rated the pain as moderate to severe. Nearly 30% of patients with an intact prosthesis required analgesics on a regular basis. Radiographs were available for fifty-eight hips (including all of the hips with moderate to severe pain) after a minimum duration of follow-up of ten years; twenty-eight of these fifty-eight hips had radiographic evidence of acetabular component migration. This bipolar cup, when used for hemiarthroplasty in patients with symptomatic arthritis of the hip, was associated with unacceptably high rates of pain, migration, osteolysis, and the need for revision to total hip arthroplasty, especially when the acetabulum had been reamed. To the extent that these findings can be generalized to similar implant designs with conventional polyethylene, we do not recommend bipolar hemiarthroplasty as the primary operative treatment for degenerative arthritis of the hip.

  7. Impact of Tranexamic Acid in Total Knee and Total Hip Replacement.

    PubMed

    Boyle, Jaclyn A; Soric, Mate M

    2017-02-01

    To evaluate the net clinical benefit of tranexamic acid use in patients undergoing total knee or total hip replacement. This is a retrospective study of patients undergoing total knee or total hip replacement. The primary outcome was the net clinical benefit of tranexamic acid use. Secondary outcomes included length of stay, incidence of venous thromboembolism, change in hemoglobin, and number of units of blood transfused. Four hundred and six patients were screened for inclusion and 327 patients met inclusion criteria; 174 patients received tranexamic acid versus 153 patients who received usual care. Tranexamic acid demonstrated a positive net clinical benefit versus usual care (40.8% vs 13.7%, P < .01) but did not affect length of stay (3.39 vs 3.37 days, respectively, P = .76). Venous thromboembolism was comparable between groups (2.3% vs 0.7%, P = .38). Average change in hemoglobin and need for transfusion were lower in the treatment group versus the usual care group, respectively (3.46 vs 4.26 mg/dL, P < .01). Tranexamic acid demonstrated a significant benefit in decreasing change in hemoglobin as well as the need for blood transfusion with no increase in the risk of venous thromboembolism in patients undergoing total knee or total hip replacement.

  8. One step HIP canning of powder metallurgy composites

    NASA Technical Reports Server (NTRS)

    Juhas, John J. (Inventor)

    1990-01-01

    A single step is relied on in the canning process for hot isostatic pressing (HIP) powder metallurgy composites. The binders are totally removed while the HIP can of compatible refractory metal is sealed at high vacuum and temperature. This eliminates outgassing during hot isostatic pressing.

  9. [Hip resurfacing arthroplasty].

    PubMed

    Witzleb, W-C; Knecht, A; Beichler, T; Köhler, T; Günther, K-P

    2004-11-01

    In comparison to stemmed total hip replacements, hip resurfacing offers advantages especially in joint stability and amount of femoral bone resection. After the poor results achieved with this concept that were mainly caused by failure of the materials used, reintroduction of the metal-on-metal bearing initiated a renaissance. This bearing, the cementless cup, and the improved surgical technique led to better short- to medium-term results. Revision and complication rates are now comparable to conventional total hip replacements. The functional capacity of the method is higher. Because long-term results are not available, however, questions remain, for instance, the consequences of the higher metal ion serum concentrations or the impossibility of changing the inlay when femoral revision becomes necessary.

  10. [Gluteal compartment syndrome after total hip replacement. A presentation of two cases].

    PubMed

    Villalba, J; Solernou, X

    2013-01-01

    Many postoperative complications have been described after a total hip arthroplasty, with early and acute, as well as late, complications being reported. Two cases of compartment syndrome of the buttock are described following a hybrid total hip arthroplasty (cemented stem and press-fit and screwed acetabulum) performed on 2 patients of 60 and 68 years old, both diagnosed and treated 24-48 hours after the surgery. Both cases had a primary prosthesis with no previous significant pathological findings. This condition is still rare, and few cases have been described at the medical literature. Copyright © 2012 SECOT. Published by Elsevier Espana. All rights reserved.

  11. Effect of tranexamic acid administration on bleeding in primary total hip arthroplasty.

    PubMed

    Fernández-Cortiñas, A B; Quintáns-Vázquez, J M; Gómez-Suárez, F; Murillo, O Simón; Sánchez-López, B R; Pena-Gracía, J M

    To study the efficacy of tranexamic acid to decrease perioperative bleeding in patients who have undergone a total hip arthroplasty operation and to evaluate drug safety. Observational, prospective, controlled and randomized study on the efficacy of tranexamic acid as a method to reduce bleeding in primary hip replacement surgery. We included 134 patients operated during 2014 in our centre, who were divided into 2 groups according to whether or not they had received tranexamic acid. The main study variables were haemoglobin and haematocrit levels, the amount of blood collected from the post-operative drain in the first 12, 24 and 48hours and transfusion requirements. Post-operative haemoglobin and haematocrit levels were statistically higher (P<.001) in the group with treatment. During the first 48hours bleeding values from the group that did not receive TAX were higher compared to patients treated with tranexamic acid. Statistically significant differences (P=.001) were found as to the need for transfusion according to group, more transfusions were performed in the cohort that had not received tranexamic acid: 25.37% compared to 4.48% for the group with tranexamic acid. No adverse events related to administration of tranexamic acid were recorded. Administration of tranexamic acid has proved to be an effective and safe method to reduce peri-operative bleeding in patients who underwent total hip arthroplasty and avoids allogenic blood transfusion. Therefore, tranexamic acid treatment could entail a financial saving for the healthcare system and expose the patient to less risk. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Modes of failure of Osteonics constrained tripolar implants: a retrospective analysis of forty-three failed implants.

    PubMed

    Guyen, Olivier; Lewallen, David G; Cabanela, Miguel E

    2008-07-01

    The Osteonics constrained tripolar implant has been one of the most commonly used options to manage recurrent instability after total hip arthroplasty. Mechanical failures were expected and have been reported. The purpose of this retrospective review was to identify the observed modes of failure of this device. Forty-three failed Osteonics constrained tripolar implants were revised at our institution between September 1997 and April 2005. All revisions related to the constrained acetabular component only were considered as failures. All of the devices had been inserted for recurrent or intraoperative instability during revision procedures. Seven different methods of implantation were used. Operative reports and radiographs were reviewed to identify the modes of failure. The average time to failure of the forty-three implants was 28.4 months. A total of five modes of failure were observed: failure at the bone-implant interface (type I), which occurred in eleven hips; failure at the mechanisms holding the constrained liner to the metal shell (type II), in six hips; failure of the retaining mechanism of the bipolar component (type III), in ten hips; dislocation of the prosthetic head at the inner bearing of the bipolar component (type IV), in three hips; and infection (type V), in twelve hips. The mode of failure remained unknown in one hip that had been revised at another institution. The Osteonics constrained tripolar total hip arthroplasty implant is a complex device involving many parts. We showed that failure of this device can occur at most of its interfaces. It would therefore appear logical to limit its application to salvage situations.

  13. Investigation into three dimensional hip anatomy in anterior dislocation after THA. Influence of the position of the hip rotation centre.

    PubMed

    Sariali, Elhadi; Klouche, Shahnez; Mamoudy, Patrick

    2012-07-01

    The components position is a major factor under the surgeon's control in determining the risk of dislocation post total hip arthroplasty. The aim of this study was to investigate the proper three-dimensional components position including the centre of rotation in the case of anterior dislocation. Among 1764 consecutive patients who underwent total hip arthroplasty using a direct anterior approach, 27 experienced anterior dislocation. The three-dimensional hip anatomy was investigated in 12 patients who were paired with 12 patients from the same initial cohort who did not experience dislocation and also with 36 control patients with osteoarthritis. A pelvic Cartesian referential was defined to perform the acetabular analysis. The coordinates were expressed as percentages of the pelvic width, height and depth. The anteversion angles were measured. The hip centre of rotation was significantly shifted medially and posteriorly in the dislocation group when compared to the non-dislocation group and also to the control group. There was no significant difference in component angular position between the dislocation-group and the non-dislocation group. However, the stem anteversion in the dislocation group was increased in comparison to the mean natural femoral anteversion of the control group. A medial and posterior displacement of the hip rotation centre was found to correlate to anterior dislocation post total hip arthoplasty. These results suggest the importance of an accurate restoration of the centre of rotation, whilst avoiding an excessive acetabular reaming which may induce a medial and a posterior displacement. III comparative non randomised. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Effects of Hip Strengthening on Neuromuscular Control, Hip Strength, and Self-Reported Functional Deficits in Individuals With Chronic Ankle Instability.

    PubMed

    Smith, Brent I; Curtis, Denice; Docherty, Carrie L

    2018-06-12

    Deficits in ankle and hip strength and lower-extremity postural control are associated with chronic ankle instability (CAI). Following strength training, muscle groups demonstrate increased strength. This change is partially credited to improved neuromuscular control, and many studies have investigated ankle protocols for subjects with CAI. The effects of isolating hip musculature in strength training protocols in this population are not well understood. To examine the effects of hip strengthening on clinical and self-reported outcomes in patients with CAI. Prospective randomized controlled clinical trial. Athletic training facility. Twenty-six participants with CAI (12 males and 14 females; age = 20.9 [1.5] y, height = 170.0 [12.7] cm, and mass = 77.5 [17.5] kg) were randomly assigned to training or control groups. Participants completed either 4 weeks of supervised hip strengthening (resistance bands 3 times a week) or no intervention. Participants were assessed on 4 clinical measures (Star Excursion Balance Test in the anterior, posteromedial, and posterolateral directions; Balance Error Scoring System; hip external rotation strength; and hip abduction strength) and a patient-reported measure (the Foot and Ankle Ability Measure activities of daily living and sports subscales) before and after the 4-week training period. The training group displayed significantly improved posttest measures compared with the control group for hip abduction strength (training: 446.3 [77.4] N, control: 314.7 [49.6] N, P < .01); hip external rotation strength (training: 222.1 [48.7] N, control: 169.4 [34.6] N, P < .01); Star Excursion Balance Test reach in the anterior (training: 93.1% [7.4%], control: 90.2% [7.9%], P < .01), posteromedial (training: 96.3% [8.9%], control: 88.0% [8.8%], P < .01), and posterolateral (training: 95.4% [11.1%], control: 86.6% [9.6%], P < .01) directions; Balance Error Scoring System total errors (training: 9.9 [6.3] errors, control: 21.2 [6.3] errors, P < .01); and the Foot and Ankle Ability Measure-sports score (training: 88.0 [12.6], control: 84.8 [10.9], P < .01). Improved clinical and patient-reported outcomes in the training group suggest hip strengthening is beneficial in the management and prevention of recurrent symptoms associated with CAI.

  15. A case report of idiopathic iliopsoas hematoma which occurred soon after transfer to the wheelchair after total hip arthroplasty.

    PubMed

    Okumura, Tomoo; Fujita, Hiroshi; Harada, Hideto; Nishimura, Ryuuichi; Tominaga, Tomohiro

    2017-02-01

    A 79-year-old woman was diagnosed with osteoarthritis of the left hip and scheduled for total hip arthroplasty. As two lesions were detected in branches of the coronary arteries, she was treated with catheter treatment. The patient was receiving anticoagulant treatment, which was suspended eight days before the operation; however, heparin was started at 6 days before the operation and was stopped 9 hours before the operation. On the 2nd postoperative day soon after transfer to the wheel chair, she was feeling unwell and was suffering from severe pain in her left buttock and left thigh. Her blood pressure had decreased to 70 mmHg. During abdominal contrast-enhanced CT, a hematoma was detected in the left iliopsoas muscle. Catheter therapy was started by the cardiovascular department and bleeding had stopped spontaneously. The patient was able to walk with a cane and was discharged on the 40th postoperative day. THA: total hip arthroplasty, CT: computed tomography, JOA score: Japanese Orthopaedic Association hip score, HA: hydroxyapatite, PMMA: polymethyl-methacrylate, APTT: activated partial thromboplastin time.

  16. Mid-term results of the BIOLOX delta ceramic-on-ceramic total hip arthroplasty.

    PubMed

    Lee, Y K; Ha, Y C; Yoo, J-I; Jo, W L; Kim, K-C; Koo, K H

    2017-06-01

    We conducted a prospective study of a delta ceramic total hip arthroplasty (THA) to determine the rate of ceramic fracture, to characterise post-operative noise, and to evaluate the mid-term results and survivorship. Between March 2009 and March 2011, 274 patients (310 hips) underwent cementless THA using a delta ceramic femoral head and liner. At each follow-up, clinical and radiological outcomes were recorded. A Kaplan-Meier analysis was undertaken to estimate survival. Four patients (four hips) died and 18 patients (20 hips) were lost to follow-up within five years. The remaining 252 patients (286 hips) were followed for a mean of 66.5 months (60 to 84). There were 144 men (166 hips) and 108 women (120 hips) with a mean age of 49.7 years (16 to 83) at surgery. The mean pre-operative Harris Hip Score of 47.1 points improved to 93.8 points at final follow-up. Six patients reported squeaking in seven hips; however, none were audible. Radiolucent lines involving Gruen zones one and/or seven were seen in 52 hips (18.2%). No hip had detectable wear, focal osteolysis or signs of loosening. One hip was revised because of fracture of the ceramic liner, which occurred due to an undetected malseating of the ceramic liner at the time of surgery. One hip was revised for a periprosthetic fracture of the femur, and one hip was treated for periprosthetic joint infection. The six-year survivorship with re-operation for any reason as the endpoint was 99.0% (95% confidence interval 97.8% to 100%). The rate of delta ceramic fracture was 0.3% (one of 286). While ceramic head fracture was dominant in previous ceramic-on-ceramic THA, fracture of the delta ceramic liner due to malseating is a concern. Cite this article: Bone Joint J 2017;99-B:741-8. ©2017 The British Editorial Society of Bone & Joint Surgery.

  17. Metal Ion Concentrations in Body Fluids after Implantation of Hip Replacements with Metal-on-Metal Bearing – Systematic Review of Clinical and Epidemiological Studies

    PubMed Central

    Hartmann, Albrecht; Hannemann, Franziska; Lützner, Jörg; Seidler, Andreas; Drexler, Hans; Günther, Klaus-Peter; Schmitt, Jochen

    2013-01-01

    Introduction The use of metal-on-metal (MoM) total hip arthroplasty (THA) increased in the last decades. A release of metal products (i.e. particles, ions, metallo-organic compounds) in these implants may cause local and/or systemic adverse reactions. Metal ion concentrations in body fluids are surrogate measures of metal exposure. Objective To systematically summarize and critically appraise published studies concerning metal ion concentrations after MoM THA. Methods Systematic review of clinical trials (RCTs) and epidemiological studies with assessment of metal ion levels (cobalt, chromium, titanium, nickel, molybdenum) in body fluids after implantation of metalliferous hip replacements. Systematic search in PubMed and Embase in January 2012 supplemented by hand search. Standardized abstraction of pre- and postoperative metal ion concentrations stratified by type of bearing (primary explanatory factor), patient characteristics as well as study quality characteristics (secondary explanatory factors). Results Overall, 104 studies (11 RCTs, 93 epidemiological studies) totaling 9.957 patients with measurement of metal ions in body fluids were identified and analyzed. Consistently, median metal ion concentrations were persistently elevated after implantation of MoM-bearings in all investigated mediums (whole blood, serum, plasma, erythrocytes, urine) irrespective of patient characteristics and study characteristics. In several studies very high serum cobalt concentrations above 50 µg/L were measured (detection limit typically 0.3 µg/L). Highest metal ion concentrations were observed after treatment with stemmed large-head MoM-implants and hip resurfacing arthroplasty. Discussion Due to the risk of local and systemic accumulation of metallic products after treatment with MoM-bearing, risk and benefits should be carefully balanced preoperatively. The authors support a proposed „time out“ for stemmed large-head MoM-THA and recommend a restricted indication for hip resurfacing arthroplasty. Patients with implanted MoM-bearing should receive regular and standardized monitoring of metal ion concentrations. Further research is indicated especially with regard to potential systemic reactions due to accumulation of metal products. PMID:23950923

  18. ValuedCare program: a population health model for the delivery of evidence-based care across care continuum for hip fracture patients in Eastern Singapore.

    PubMed

    Mittal, Chikul; Lee, Hsien Chieh Daniel; Goh, Kiat Sern; Lau, Cheng Kiang Adrian; Tay, Leeanna; Siau, Chuin; Loh, Yik Hin; Goh, Teck Kheng Edward; Sandi, Chit Lwin; Lee, Chien Earn

    2018-05-30

    To test a population health program which could, through the application of process redesign, implement multiple evidence-based practices across the continuum of care in a functionally integrated health delivery system and deliver highly reliable and consistent evidence-based surgical care for patients with fragility hip fractures in an acute tertiary general hospital. The ValuedCare (VC) program was developed in three distinct phases as an ongoing collaboration between the Geisinger Health System (GHS), USA, and Changi General Hospital (CGH), Singapore, modelled after the GHS ProvenCare® Fragile Hip Fracture Program. Clinical outcome data on consecutive hip fracture patients seen in 12 months pre-intervention were then compared with the post-intervention group. Both pre- and post-intervention groups were followed up across the continuum of care for a period of 12 months. VC patients showed significant improvement in median time to surgery (97 to 50.5 h), as well as proportion of patients operated within 48 h from hospital admission (48% from 18.8%) as compared to baseline pre-intervention data. These patients also had significant reduction (p value < 0.001) of acute inpatient complications such as delirium, pneumonia, urinary tract infections, and pressure sores. VC program has shown significant reduction in median length of stay for acute hospital (13 to 9 days) as well as median combined length of stay for acute and sub-acute rehabilitation hospital (46 to 39 days), thus reducing the total duration of hospitalization and saving total hospital bed days. Operative and inpatient mortality, together with readmission rates, remained low and comparable to international Geriatric Fracture Centers (GFCs). The implementation of VC methodology has enabled consistent delivery of high-quality, reliable and comprehensive evidence-based care for hip fracture patients at Changi General Hospital. This has also reflected successful change management and interdisciplinary collaboration within the organization through the program. There is potential for testing this methodology as a quality improvement framework replicable to other disease groups in a functionally integrated healthcare system.

  19. Patient-oriented Functional Results of Total Femoral Endoprosthetic Reconstruction Following Oncologic Resection

    PubMed Central

    Jones, Kevin B.; Griffin, Anthony M.; Chandrasekar, Coonoor R.; Biau, David; Babinet, Antoine; Deheshi, Benjamin; Bell, Robert S.; Grimer, Robert J.; Wunder, Jay S.; Ferguson, Peter C.

    2011-01-01

    Background and Objectives Functional outcomes following oncologic total femoral endoprosthetic reconstruction (TFR) are lacking. We compared patient-oriented functional results of TFRs to proximal femur and distal femur reconstructions (PFR and DFR). We also compared function and complications with regard to knee and hip componentry. Methods 54 TFR patients were identified from 3 institutional prospective databases. 41 had fixed- and 13 had rotating-hinge knees, 37 hemiarthroplasty and 17 total hip arthroplasty componentry. Toronto Extremity Salvage Scores (TESS) for n=27 were compared between groups and to cohorts of PFR (n=31) and DFR (n=85) patients using the Mann-Whitney U test. Results Follow-up averaged 4 years. Mechanical complications included 5 hip dislocations and 1 femoral malrotation. Four dislocations were in fixed-hinge implants, all in those lacking abductor reattachment. TESS averaged 69.3±17.8, statistically decreased from DFR (p=0.002) and PFR patients (p=0.036). No significant differences were detected between patients in the fixed-hinge (n=18) and rotating-hinge (n=9) groups (p = 0.944), or total hip (n=8) and hemiarthroplasty (n=19) groups (p=0.633). Conclusions TFR is reserved for extreme cases of limb salvage, portending a poor prognosis overall. Function reflects additive impairments from PFR and DFR. TFR outcomes differ little with rotating- or fixed-hinge, total hip or hemiarthroplasty implants. PMID:21695701

  20. Childhood cerebral palsy and the use of positioning systems to control body posture: Current practices.

    PubMed

    Pérez-de la Cruz, S

    One of the consequences of poor postural control in children with cerebral palsy is hip dislocation. This is due to the lack of weight-bearing in the sitting and standing positions. Orthotic aids can be used to prevent onset and/or progression. The aim of this study is to analyse the effectiveness of positioning systems in achieving postural control in patients with cerebral palsy, and discuss these findings with an emphasis on what may be of interest in the field of neurology. We selected a total of 18 articles on interventions in cerebral palsy addressing posture and maintenance of ideal postures to prevent deformities and related problems. The main therapeutic approaches employed combinations of botulinum toxin and orthoses, which reduced the incidence of hip dislocation although these results were not significant. On the other hand, using positioning systems in 3 different positions decreases use of botulinum toxin and surgery in children under 5 years old. The drawback is that these systems are very uncomfortable. Postural control systems helps control hip deformities in children with cerebral palsy. However, these systems must be used for prolonged periods of time before their effects can be observed. Copyright © 2015 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Fibroblast growth factor 23, bone mineral density, and risk of hip fracture among older adults: the cardiovascular health study.

    PubMed

    Jovanovich, Anna; Bùzková, Petra; Chonchol, Michel; Robbins, John; Fink, Howard A; de Boer, Ian H; Kestenbaum, Bryan; Katz, Ronit; Carbone, Laura; Lee, Jennifer; Laughlin, Gail A; Mukamal, Kenneth J; Fried, Linda F; Shlipak, Michael G; Ix, Joachim H

    2013-08-01

    Fibroblast growth factor 23 (FGF23) is a phosphaturic hormone that also inhibits calcitriol synthesis. Our objective was to evaluate the relationships of plasma FGF23 concentrations with bone mineral density (BMD) and hip fracture in community-dwelling older adults. Linear regression and Cox proportional hazard models were used to examine the associations of plasma FGF23 concentrations with BMD and incident hip fracture, respectively. Analyses were also stratified by chronic kidney disease. Participants included 2008 women and 1329 men ≥65 years from the 1996 to 1997 Cardiovascular Health Study visit. Dual x-ray absorptiometry measured total hip (TH) and lumbar spine (LS) BMD in 1291 participants. Hip fracture incidence was assessed prospectively through June 30, 2008 by hospitalization records in all participants. Women had higher plasma FGF23 concentrations than men (75 [56-107] vs 66 [interquartile range = 52-92] relative units/mL; P < .001). After adjustment, higher FGF23 concentrations were associated with greater total hip and lumbar spine BMD in men only (β per doubling of FGF23 = 0.02, with 95% confidence interval [CI] = 0.001-0.04 g/cm(2), and 0.03 with 95% CI = 0.01-0.06 g/cm(2)). During 9.6 ± 5.1-11.0 years of follow-up, 328 hip fractures occurred. Higher FGF23 concentrations were not associated with hip fracture risk in women or men (adjusted hazard ratio = 0.95, with 95% CI = 0.78-1.15, and 1.09 with 95% CI = 0.82-1.46 per doubling of FGF23). Results did not differ by chronic kidney disease status (P > .4 for interactions). In this large prospective cohort of community-dwelling older adults, higher FGF23 concentrations were weakly associated with greater lumbar spine and total hip BMD but not with hip fracture risk.

  2. Is lower hip range of motion a risk factor for groin pain in athletes? A systematic review with clinical applications

    PubMed Central

    Tak, Igor; Engelaar, Leonie; Gouttebarge, Vincent; Barendrecht, Maarten; Van den Heuvel, Sylvia; Kerkhoffs, Gino; Langhout, Rob; Stubbe, Janine; Weir, Adam

    2017-01-01

    Background Whether hip range of motion (ROM) is a risk factor for groin pain in athletes is not known. Objectives To systematically review the relationship between hip ROM and groin pain in athletes in cross-sectional/case–control and prospective studies. Study design Systematic review, prospectively registered (PROSPERO) according to PRISMA guidelines. Methods Pubmed, Embase, CINAHL and SPORTDiscus were systematically searched up to December 2015. Two authors performed study selection, data extraction/analysis, quality assessment (Critical Appraisal Skills Programme) and strength of evidence synthesis. Results We identified seven prospective and four case–control studies. The total quality score ranged from 29% to 92%. Heterogeneity in groin pain classification, injury definitions and physical assessment precluded data pooling. There was strong evidence that total rotation of both hips below 85° measured at the pre-season screening was a risk factor for groin pain development. Strong evidence suggested that internal rotation, abduction and extension were not associated with the risk or presence of groin pain. Conclusion Total hip ROM is the factor most consistently related to groin pain in athletes. Screening for hip ROM is unlikely to correctly identify an athlete at risk of developing groin pain because of the small ROM differences found and poor ROM measurement properties. PMID:28432076

  3. Gait symmetry and hip strength in women with developmental dysplasia following hip arthroplasty compared to healthy subjects: A cross-sectional study.

    PubMed

    Leijendekkers, Ruud A; Marra, Marco A; Kolk, Sjoerd; van Bon, Geert; Schreurs, B Wim; Weerdesteyn, Vivian; Verdonschot, Nico

    2018-01-01

    Untreated unilateral developmental dysplasia of the hip (DDH) results in asymmetry of gait and hip strength and may lead to early osteoarthritis, which is commonly treated with a total hip arthroplasty (THA). There is limited knowledge about the obtained symmetry of gait and hip strength after the THA. The objectives of this cross-sectional study were to: a) identify asymmetries between the operated and non-operated side in kinematics, kinetics and hip strength, b) analyze if increased walking speed changed the level of asymmetry in patients c) compare these results with those of healthy subjects. Women (18-70 year) with unilateral DDH who had undergone unilateral THA were eligible for inclusion. Vicon gait analysis system was used to collect frontal and sagittal plane kinematic and kinetic parameters of the hip joint, pelvis and trunk during walking at comfortable walking speed and increased walking speed. Furthermore, hip abductor and extensor muscle strength was measured. Six patients and eight healthy subjects were included. In the patients, modest asymmetries in lower limb kinematics and kinetics were present during gait, but trunk lateral flexion asymmetry was evident. Patients' trunk lateral flexion also differed compared to healthy subjects. Walking speed did not significantly influence the level of asymmetry. The hip abduction strength asymmetry of 23% was not statistically significant, but the muscle strength of both sides were significantly weaker than those of healthy subjects. In patients with a DDH treated with an IBG THA modest asymmetries in gait kinematics and kinetics were present, with the exception of a substantial asymmetry of the trunk lateral flexion. Increased walking speed did not result in increased asymmetries in gait kinematics and kinetics. Hip muscle strength was symmetrical in patients, but significantly weaker than in healthy subjects. Trunk kinematics should be included as an outcome measure to assess the biomechanical benefits of the THA surgery after DDH.

  4. Fluctuation of Cup Orientation During Press-Fit Insertion: A Possible Cause of Malpositioning.

    PubMed

    Nishii, Takashi; Sakai, Takashi; Takao, Masaki; Sugano, Nobuhiko

    2015-10-01

    We evaluated real-time angular changes during press-fit cup insertion in 70 total hip arthroplasties. Inclination and anteversion cup angles on navigation system were recorded after each procedure of five hammer blows during cup insertion, and maximum deviated inclination (MDI) and anteversion (MDA) angles until the cup was fully seated were measured. We found 1 (1%) and 29 (41%) hips with increases and decreases in MDI of 5° or more, and 13 (19%) and 6 (8%) hips with increases and decreases in MDA of 5° or more, respectively. The MDI in men was significantly lower and the MDA for left-side surgery was significantly higher. Surgeons should pay attention to fluctuation in angular changes during cup insertion and may consider countermeasures to minimize cup malpositioning. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Computer-assisted total hip arthroplasty: coding the next generation of navigation systems for orthopedic surgery.

    PubMed

    Renkawitz, Tobias; Tingart, Markus; Grifka, Joachim; Sendtner, Ernst; Kalteis, Thomas

    2009-09-01

    This article outlines the scientific basis and a state-of-the-art application of computer-assisted orthopedic surgery in total hip arthroplasty (THA) and provides a future perspective on this technology. Computer-assisted orthopedic surgery in primary THA has the potential to couple 3D simulations with real-time evaluations of surgical performance, which has brought these developments from the research laboratory all the way to clinical use. Nonimage- or imageless-based navigation systems without the need for additional pre- or intra-operative image acquisition have stood the test to significantly reduce the variability in positioning the acetabular component and have shown precise measurement of leg length and offset changes during THA. More recently, computer-assisted orthopedic surgery systems have opened a new frontier for accurate surgical practice in minimally invasive, tissue-preserving THA. The future generation of imageless navigation systems will switch from simple measurement tasks to real navigation tools. These software algorithms will consider the cup and stem as components of a coupled biomechanical system, navigating the orthopedic surgeon to find an optimized complementary component orientation rather than target values intraoperatively, and are expected to have a high impact on clinical practice and postoperative functionality in modern THA.

  6. [EFFECTIVENESS OF BILATERAL TOTAL HIP AND KNEE ARTHROPLASTY FOR SEVERE INFLAMMATORY ARTHROPATHIES].

    PubMed

    Li, Xin; Li, Heng; Ni, Ming; Li, Xiang; Song, Xinggui; Kong, Xiangpeng; Li, Yucong; Chen, Jiying

    2016-11-08

    To evaluate the application and effectiveness of bilateral total hip arthroplasty and total knee arthroplasty in the treatment of severe inflammatory arthropathies. Between September 2008 and September 2015, 31 patients with severe inflammatory arthropathies were treated with bilateral total hip arthroplasty and total knee arthroplasty. Of 31 cases, 22 were male and 9 were female with an average age of 30 years (range, 20 to 41 years); there were 15 cases of rheumatoid arthritis and 16 cases of ankylosing spondylitis with an average onset age of 14 years (range, 5-28 years); all 4 ankylosed joints were observed in 11 cases, 3 ankylosed joints in 2 cases, 2 ankylosed joints in 6 cases, 1 ankylosed joint in 1 case, and no ankylosed joint in 11 cases. Before operation, the hip range of motion (ROM) value was (17.82±28.18)°, and the knee ROM value score was (26.45±30.18)°; the hip Harris score was 29.64±11.58, and the hospital for special surgery (HSS) score was 27.07±11.04. The patients were grouped and compared in accordance with etiology and ankylosed joint. One-stage arthroplasty was performed in 1 case, two-stage arthroplasty in 22 cases, three-stage arthroplasty in 7 cases, and four-stage arthroplasty in 1 case. The total operation time was 325-776 minutes; the total blood loss was 900-3 900 mL; the total transfusion volume was 2 220-8 070 mL; and the total hospitalization time was 21-65 days. The patients were followed up 12-94 months (mean, 51 months). The hip and knee ROM values, Harris score and HSS score at last follow-up were significantly improved when compared with preoperative ones ( P <0.05). The subjective satisfaction degree was good in 16 cases, moderate in 10 cases, and poor in 5 cases. Periprosthetic infection occurred in 2 cases (3 knees), joint stiffness in 3 cases (6 knees), joint instability in 1 case (1 knee), leg length discrepancy of >2 cm in 2 cases, and flexion deformity of 10° in 1 case (1 knee). The hip and knee ROM values, Harris score and HSS score showed no significant difference between patients with ankylosing spondylitis and patients rheumatoid arthritis at last follow-up ( P >0.05). The hip and knee ROM values of the patients with ankylosed joint were significantly lower than those of patients with no ankylosed joint ( P <0.05); the Harris score and HSS score of the patients with ankylosed joint were lower than those of patients with no ankylosed joint, but no significant difference was found ( P >0.05). A combination of bilateral hip and knee arthroplasty is an efficient treatment for severe lower extremities deformity, arthralgia and poor quality of life caused by inflammatory arthropathies. However, the postoperative periprosthetic infection and stiffness of knee are important complications influencing the effectiveness of operation.

  7. The incidence of total hip arthroplasty after hip arthroscopy in osteoarthritic patients

    PubMed Central

    2010-01-01

    Objective To assess the incidence of total hip arthroplasty (THA) in osteoarthritic patients who were treated by arthroscopic debridement and to evaluate factors that might influence the time interval from the first hip arthroscopy to THA. Design Retrospective clinical series Methods Follow-up data and surgical reports were retrieved from 564 records of osteoarthritic patients that have had hip arthroscopy between the years 2002 to 2009 with a mean follow-up time of 3.2 years (range, 1-6.4 years). The time interval between the first hip arthroscopy to THA was modelled as a function of patient age; level of cartilage damage; procedures performed and repeated arthroscopies with the use of multivariate regression analysis. Results Ninety (16%) of all participants eventually required THA. The awaiting time from the first arthroscopy to a hip replacement was found to be longer in patients younger than 55 years and in a milder osteoarthritic stage. Patients that experienced repeated hip scopes had a longer time to THA than those with only a single procedure. Procedures performed concomitant with debridement and lavage did not affect the time interval to THA. Conclusions In our series of arthroscopic treatment of hip osteoarthritis, 16% required THA over a period of 7 years. Factors that influence the time to arthroplasty were age, degree of osteoarthritis and recurrent procedures. PMID:20670440

  8. Does Choice of Head Size and Neck Geometry Affect Stem Migration in Modular Large-Diameter Metal-on-Metal Total Hip Arthroplasty? A Preliminary Analysis

    PubMed Central

    Georgiou, CS; Evangelou, KG; Theodorou, EG; Provatidis, CG; Megas, PD

    2012-01-01

    Due to their theoretical advantages, hip systems combining modular necks and large diameter femoral heads have gradually gained popularity. However, among others, concerns regarding changes in the load transfer patterns were raised. Recent stress analyses have indeed shown that the use of modular necks and big femoral heads causes significant changes in the strain distribution along the femur. Our original hypothesis was that these changes may affect early distal migration of a modular stem. We examined the effect of head diameter and neck geometry on migration at two years of follow-up in a case series of 116 patients (125 hips), who have undergone primary Metal-on-Metal total hip arthroplasty with the modular grit-blasted Profemur®E stem combined with large-diameter heads (>36 mm). We found that choice of neck geometry and head diameter has no effect on stem migration. A multivariate regression analysis including the potential confounding variables of the body mass index, bone quality, canal fill and stem positioning revealed only a negative correlation between subsidence and canal fill in midstem area. Statistical analysis, despite its limitations, did not confirm our hypothesis that choice of neck geometry and/or head diameter affects early distal migration of a modular stem. However, the importance of correct stem sizing was revealed. PMID:23284597

  9. Does Choice of Head Size and Neck Geometry Affect Stem Migration in Modular Large-Diameter Metal-on-Metal Total Hip Arthroplasty? A Preliminary Analysis.

    PubMed

    Georgiou, Cs; Evangelou, Kg; Theodorou, Eg; Provatidis, Cg; Megas, Pd

    2012-01-01

    Due to their theoretical advantages, hip systems combining modular necks and large diameter femoral heads have gradually gained popularity. However, among others, concerns regarding changes in the load transfer patterns were raised. Recent stress analyses have indeed shown that the use of modular necks and big femoral heads causes significant changes in the strain distribution along the femur. Our original hypothesis was that these changes may affect early distal migration of a modular stem. We examined the effect of head diameter and neck geometry on migration at two years of follow-up in a case series of 116 patients (125 hips), who have undergone primary Metal-on-Metal total hip arthroplasty with the modular grit-blasted Profemur®E stem combined with large-diameter heads (>36 mm). We found that choice of neck geometry and head diameter has no effect on stem migration. A multivariate regression analysis including the potential confounding variables of the body mass index, bone quality, canal fill and stem positioning revealed only a negative correlation between subsidence and canal fill in midstem area. Statistical analysis, despite its limitations, did not confirm our hypothesis that choice of neck geometry and/or head diameter affects early distal migration of a modular stem. However, the importance of correct stem sizing was revealed.

  10. Bilateral Total Hip Arthroplasty: 1-Stage or 2-Stage? A Meta-Analysis.

    PubMed

    Shao, Hongyi; Chen, Chi-Lung; Maltenfort, Mitchell G; Restrepo, Camilo; Rothman, Richard H; Chen, Antonia F

    2017-02-01

    Total hip arthroplasty (THA) is one of the most successful orthopedic surgeries performed in the last 50 years. However, controversies still exist between conducting 1- or 2-stage bilateral THA. Using PubMed, Ovid, Embase, and Cochrane library databases, we searched for papers written between January 1995 and October 2015 that contained the following search terms: "one-stage or two-stage" or "simultaneous or staged," and "hip" and "arthroplasty or replacement." A meta-analysis was conducted with the collected pooled data about major and minor systemic complications, surgical complications, and other perioperative data associated with 1- and 2-stage bilateral THA. Statistical analysis was performed by the Mantel-Haenszel method, and the fixed effect model was used to analyze data. There were 13 studies with 17,762 patients who underwent 1-stage bilateral THA and 46,147 patients who underwent 2-stage bilateral THA. One-stage bilateral THA had a lower risk of major systemic complications, less deep venous thrombosis, and shorter operative time compared with 2-stage bilateral THA. There were no significant differences in death, pulmonary embolism, cardiovascular complication, infections, minor complications, and other surgical complications between procedures. One-stage bilateral THA was superior to 2-stage bilateral THA in terms of major systemic complication, deep venous thrombosis, and surgical time compared with 2-stage bilateral THA. However, this study does not encourage performing 1-stage over 2-stage bilateral THA. Higher evidence level studies are necessary for further analysis. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Trends in the phenotypic hip status of selected breeds of dog as measured by the New Zealand Veterinary Association Hip Dysplasia scheme (1990-2008).

    PubMed

    Worth, A J; Bridges, J P; Jones, G

    2011-03-01

    To determine whether there has been improvement in the phenotypic hip dysplasia status in four susceptible dog breeds as measured by the New Zealand Veterinary Association (NZVA) Canine Hip Dysplasia (CHD) scheme. A retrospective analysis of the NZVA CHD database was performed using records of all German Shepherd dogs, Labrador Retrievers, Golden Retrievers and Rottweilers that had undergone evaluation for hip dysplasia between 1990 and 2008. The effect of date of birth on the total hip score was analysed using linear regression, including the covariates of age and gender. When a significant effect of date of birth on total score was noted, ordinal logistic regression was performed to determine the probability of different grades of the Norberg angle and subluxation scores by year of birth; these categories being most indicative of laxity of the coxofemoral joint. Given the known heritability of hip phenotype, determined using radiological measurements, the hypothesis was that if sufficient selection pressure has been applied there would have been a trend towards a lower total score over time. For Labrador Retrievers (n=1,451), Golden Retrievers (n=896) and Rottweilers (n=313), there was no effect of date of birth on total score over the period of the study (p>0.1). For German Shepherd dogs (n=1,087), there was a significant trend to a lower total score over time (p=0.0003). However the actual size of the effect was small. Ordinal logistic regression on the Norberg angle and subluxation scores for German Shepherd dogs demonstrated a significant lowering of grade in both of these measures of hip laxity. This study failed to show significant improvement in the phenotypic hip status of three out of the four most populous large-dog breeds in the NZVA CHD database. Even in the German Shepherd dog, the trend towards a lower total score did not represent a substantial change. Lack of evidence of phenotypic improvement may be due to insufficient selection pressure over the course of the study, selective usage of the scheme (and thus a biased sample), or deficiencies within the NZVA CHD scoring method itself. Greater improvement might be possible if use of the scheme (or an equivalent) is made a compulsory requirement for registration of pedigree breeding stock, if greater selection pressure is applied and/or if pedigree data are included to enable estimations of breeding value.

  12. Does haptic robot-assisted total hip arthroplasty better restore native acetabular and femoral anatomy?

    PubMed

    Tsai, Tsung-Yuan; Dimitriou, Dimitris; Li, Jing-Sheng; Kwon, Young-Min

    2016-06-01

    The objective was to evaluate whether total hip arthroplasty (THA) using haptic robot assistance restores hip geometry better than the free-hand technique. Twelve robot-assisted and 14 free-hand unilateral THA patients underwent CT scan for three-dimensional (3D) hip models. The anteversion, inclination and hip joint centre locations of the native and implanted hips in each patient were quantified and compared. Significant increase of combined anteversion by 19.1 ± 11.7° and 23.5 ± 23.6° and decrease of cup inclination by 16.5 ± 6.0° and 10.2 ± 6.8° were observed in the robot-assisted and the free-hand THAs, respectively. Less variation in the difference of the component orientations (max 11.1 vs 18.3°) and the femoral head centre (max 4.5 vs 6.3 mm) were found in the robot-assisted group. This study demonstrated that neither robot-assisted nor free-hand THAs had fully restored native hip geometry. However, the higher precision of the robot-assisted THA suggested that it has potential utility in restoring the native hip geometry. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  13. Descriptive profile of hip rotation range of motion in elite tennis players and professional baseball pitchers.

    PubMed

    Ellenbecker, Todd S; Ellenbecker, Gail A; Roetert, E Paul; Silva, Rogerio Teixeira; Keuter, Greg; Sperling, Fabio

    2007-08-01

    Repetitive loading to the hip joint in athletes has been reported as a factor in the development of degenerative joint disease and intra-articular injury. Little information is available on the bilateral symmetry of hip rotational measures in unilaterally dominant upper extremity athletes. Side-to-side differences in hip joint range of motion may be present because of asymmetrical loading in the lower extremities of elite tennis players and professional baseball pitchers. Cohort (cross-sectional) study (prevalence); Level of evidence, 1. Descriptive measures of hip internal and external rotation active range of motion were taken in the prone position of 64 male and 83 female elite tennis players and 101 male professional baseball pitchers using digital photos and computerized angle calculation software. Bilateral differences in active range of motion between the dominant and nondominant hip were compared using paired t tests and Bonferroni correction for hip internal, external, and total rotation range of motion. A Pearson correlation test was used to test the relationship between years of competition and hip rotation active range of motion. No significant bilateral difference (P > .005) was measured for mean hip internal or external rotation for the elite tennis players or the professional baseball pitchers. An analysis of the number of subjects in each group with a bilateral difference in hip rotation greater than 10 degrees identified 17% of the professional baseball pitchers with internal rotation differences and 42% with external rotation differences. Differences in the elite male tennis players occurred in only 15% of the players for internal rotation and 9% in external rotation. Female subjects had differences in 8% and 12% of the players for internal and external rotation, respectively. Statistical differences were found between the mean total arc of hip range of internal and external rotation in the elite tennis players with the dominant side being greater by a clinically insignificant mean value of 2.5 degrees. Significantly less (P < .005) dominant hip internal rotation and less dominant and nondominant hip total rotation range of motion were found in the professional baseball pitchers compared with the elite male tennis players. This study established typical range of motion patterns and identified bilaterally symmetric hip active range of motion rotation values in elite tennis players and professional baseball pitchers. Asymmetric hip joint rotational active range of motion encountered during clinical examination and screening may indicate abnormalities and would indicate the application of flexibility training, rehabilitation, and further evaluation.

  14. Lunar phase does not influence perioperative complications in total hip arthroplasty.

    PubMed

    Ficklscherer, Andreas; Angermann, Alexander; Weber, Patrick; Wegener, Bernd; Pietschmann, Matthias; Müller, Peter

    2012-02-29

    Lunar calendars, publishing recommendations for daily life, are gaining more and more attention in Germany, where 10.5% of the population believe in lunar effects on disease. A widespread and often heard belief is that a full moon has the most negative effects on surgical outcome. The present study evaluates the effects of lunar phase on perioperative complications in total hip arthroplasty. We performed a retrospective study with 305 patients being provided with a primary hip arthroplasty. To identify possible influences of the lunar phase on perioperative complications we investigated data such as operation length, blood loss and course of C-reactive protein that were collected during the patients' stay in the hospital and allocated them to moon illumination. There were no significant differences in all collected data concerning the lunar phase (p > 0.05). Although not statistically significant, there were fewer operations during the full moon phase. Therefore there is no evidence that lunar phase has an effect on perioperative complications in total hip arthroplasty. Fewer, though not significantly fewer, operations were performed during the full moon phase. Although this was not a prospective randomized trial, the statistical magnitude of the results does not support any recommendations for scheduling patients for total hip arthroplasty at any particular day of the lunar phase.

  15. The Role of Hip Arthroscopy in Investigating and Managing the Painful Hip Resurfacing Arthroplasty.

    PubMed

    Mei-Dan, Omer; Pascual-Garrido, Cecilia; Moreira, Brett; McConkey, Mark O; Young, David A

    2016-03-01

    To determine the safety and efficacy of hip arthroscopy performed in the peripheral compartment as a diagnostic and therapeutic treatment option for patients with hip pain after hip resurfacing surgery. Indications for hip arthroscopy after hip resurfacing included patients with a symptomatic hip-resurfaced arthroplasties who did not respond to nonoperative treatment. Patients who underwent a hip arthroscopy after a painful hip resurfacing were included with a minimum of 1 year follow-up. Subgroup analysis was performed according to whether an established diagnosis was made before arthroscopic intervention or not. Subjective measures were based on Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores, and results were calculated and analyzed. We included 68 patients (26 male [38%] and 42 female [62%]) who underwent subsequent hip arthroscopy from a population of 978 consecutive hip-resurfaced arthroplasties performed between 1999 and 2010. The average age was 58 (range, 37 to 78 years). The mean follow-up after hip arthroscopy was 3.4 years (range, 12 months to 5.8 years). Patients who had an established diagnosis (n = 41) before hip arthroscopy showed statistical improvement in their WOMAC scores (7 to 2, P < .001). Only 3 (7%) of these 41 patients failed and were converted to a total hip replacement (THR); however, patients who did not have an established diagnosis (n = 27) before undergoing hip arthroscopy showed statistical worsening of the WOMAC (15 to 21, P = .002). Ten (37%) of these 27 patients without a diagnosis failed and needed to be converted to a THR. A significant correlation was found between the collections found on ultrasound (psoas bursa and/or in the hip joint) and the need for synovectomy (P = .01). The overall revision rate to THR after hip resurfacing in our group of patients was 1.3% (n = 13). Female patients were more likely to require postresurfacing hip arthroscopy with 42 (60%) female to only 26 (40%) male patients undergoing this procedure. In our study population, 70% (14/21, P < .05) of patients with hip pain caused by severe metal synovial reaction or metal-on-metal reaction were women. A total of 5 (7%) patients had minor-to-mild complications after hip arthroscopy. Hip arthroscopy is a safe surgical treatment option for those patients with a painful hip resurfacing arthroplasty. Having an accurate diagnosis before hip arthroscopy improves the likelihood a good outcome. Level IV - therapeutic case series. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  16. The results of a proximally-coated cementless femoral component in total hip replacement: a five- to 12-year follow-up.

    PubMed

    Kim, Y-H

    2008-03-01

    This study reviewed the results of a cementless anatomical femoral component to give immediate post-operative stability, and with a narrow distal section in order not to contact the femoral cortex in the diaphysis, ensuring exclusively metaphyseal loading. A total of 471 patients (601 hips) who had a total hip replacement between March 1995 and February 2002 were included in the study. There were 297 men and 174 women. The mean age at the time of operation was 52.7 years (28 to 63). Clinical and radiological evaluation were performed at each follow-up. Bone densitometry was carried out on all patients two weeks after operation and at the final follow-up examination. The mean follow-up was 8.8 years (5 to 12). The mean pre-operative Harris hip score was 41 points (16 to 54), which improved to a mean of 96 (68 to 100) at the final follow-up. No patient complained of thigh pain at any stage. No acetabular or femoral osteolysis was observed and no hip required revision for aseptic loosening of either component. Deep infection occurred in two hips (0.3%) which required revision. One hip (0.2%) required revision of the acetabular component for recurrent dislocation. Bone mineral densitometry revealed a minimal bone loss in the proximal femur. This cementless anatomical femoral component with metaphyseal loading but without distal fixation produced satisfactory fixation and encourages proximal femoral loading.

  17. Perioperative morbidity and mortality of total hip replacement in liver transplant recipients: a 7-year single-center experience.

    PubMed

    Aminata, Iman; Lee, Soo-Ho; Chang, Jae-Suk; Lee, Choon-Sung; Chun, Jae-Myeung; Park, Jin-Woong; Pawaskar, Aditya; Jeon, In-Ho

    2012-12-15

    This study aims to evaluate perioperative mortality and morbidity after total hip replacement in liver transplant recipients and suggesting safety guidelines. Hip replacement surgery is one of the most common elective surgeries even for organ transplant recipients. However, there is a paucity of literature addressing the morbidity and complications of hip replacement surgery for liver transplant recipients. We analyzed retrospectively 33 arthroplasty cases in 20 liver transplant recipients carried out in a single center from 2005 to 2011. All perioperative clinical and laboratory data were evaluated together with early and late morbidity and mortality. Of 2253 liver transplant recipients, 20 (0.9%) patients underwent 33 total hip arthroplasties. Thirty-two arthroplasties were performed for avascular necrosis of the femoral head, whereas only one was performed for osteoarthritis. There was no death, liver failure, or infection within 30 days after surgery. Three patients showed elevated liver enzyme more than 5 times the normal value, but it eventually decreased to normal within 1 week. Of 33 cases of arthroplasty, postoperative blood transfusion was needed in 14 cases with 1 case receiving more than 4 U. On long-term follow-up, no patients have developed periprosthetic fracture, implant loosening, or liver failure. All patients showed good to excellent postoperative Harris hip score. In this series, we can infer that hip replacement surgery in liver transplantation patients is safe and gives a reliably good result. Some preoperative conditions should be obtained to reduce postoperative morbidity.

  18. Prospective analyses of female urinary incontinence symptoms following total hip arthroplasty.

    PubMed

    Okumura, Keiko; Yamaguchi, Kumiko; Tamaki, Tatsuya; Oinuma, Kazuhiro; Tomoe, Hikaru; Akita, Keiichi

    2017-04-01

    Some patients with hip osteoarthritis report that urinary incontinence (UI) is improved following total hip arthroplasty (THA). However, the type and severity of UI remain unclear. In this study, we hypothesize that both stress urinary incontinence (SUI) and urge urinary incontinence (UUI) are improved after THA. We assess the characteristics of UI and discuss the anatomical factors related to UI and THA for improved treatment outcome. Fifty patients with UI who underwent direct anterior-approach THA were evaluated. Type of UI was assessed using four questionnaires: Core Lower Urinary Tract Symptom Score (CLSS), Urogenital Distress Inventory Short Form (UDI-6), International Prostate Symptom Score (IPSS), and Overactive Bladder Symptom Score (OABSS). Uroflowmetry and postvoid residual urine were measured using ultrasound technology. Hip-joint function was evaluated using Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and range of motion (ROM). Of the 50 patients, 21 had SUI, 16 had mixed urinary incontinence (MUI), and eight had urgency urinary incontinence (UUI). In total, 36 patients were better than improved (72 %). The rate of cured and improved was 76 % for SUI, 100 % MUI, and 50 % UUI. The improvement of ROM was more significant in cured or improved patients than in stable or worse patients. Improvement in mild UI may be an added benefit for those undergoing THA for hip-joint disorders. These data suggest that for patients with hip-joint disorder, hip-joint treatment could prove to also be a useful treatment for UI.

  19. High-energy extracorporeal shock wave therapy for nontraumatic osteonecrosis of the femoral head.

    PubMed

    Xie, Kai; Mao, Yuanqing; Qu, Xinhua; Dai, Kerong; Jia, Qingwei; Zhu, Zhenan; Yan, Mengning

    2018-02-02

    Nontraumatic osteonecrosis of the femoral head (ONFH) is treated with a series of methods. High-energy extracorporeal shock wave therapy (ESWT) is an option with promising mid-term outcomes. The objective of this study was to determine the long-term outcomes of ESWT for ONFH. Fifty-three hips in 39 consecutive patients were treated with ESWT in our hospital between January 2005 and July 2006. Forty-four hips in 31 patients with stage I-III nontraumatic ONFH, according to the Association Research Circulation Osseous (ARCO) system, were reviewed in the current retrospective study. The visual analog pain scale (VAS), Harris hip score, radiography, and magnetic resonance imaging were used to estimate treatment results. The progression of ONFH was evaluated by imaging examination and clinical outcomes. The results were classified as clinical success (no progression of hip symptoms) and imaging success (no progression of stage or substage on radiography and MRI). The mean follow-up duration was 130.6 months (range, 121 to 138 months). The mean VAS decreased from 3.8 before ESWT to 2.2 points at the 10-year follow-up (p < 0.001). The mean Harris hip score improved from 77.4 before ESWT to 86.9 points at the 10-year follow-up. The clinical success rates were 87.5% in ARCO stage I patients, 71.4% in ARCO stage II patients, and 75.0% in ARCO stage III patients. Imaging success was observed in all stage I hips, 64.3% of stage II hips, and 12.5% of stage III hips. Seventeen hips showed progression of the ARCO stage/substage on imaging examination. Eight hips showed femoral head collapse at the 10-year follow-up. Four hips in ARCO stage III and one hip in ARCO stage II were treated with total hip arthroplasty during the follow-up. Three were performed 1 year after ESWT, one at 2 years, and one at 5 years. The results of the current study indicated that ESWT is an effective treatment method for nontraumatic ONFH, resulting in pain relief and function restoration, especially for patients with ARCO stage I-II ONFH.

  20. Association between contact hip stress and RSA-measured wear rates in total hip arthroplasties of 31 patients.

    PubMed

    The, Bertram; Hosman, Anton; Kootstra, Johan; Kralj-Iglic, Veronika; Flivik, Gunnar; Verdonschot, Nico; Diercks, Ron

    2008-01-01

    The main concern in the long run of total hip replacements is aseptic loosening of the prosthesis. Optimization of the biomechanics of the hip joint is necessary for optimization of long-term success. A widely implementable tool to predict biomechanical consequences of preoperatively planned reconstructions still has to be developed. A potentially useful model to this purpose has been developed previously. The aim of this study is to quantify the association between the estimated hip joint contact force by this biomechanical model and RSA-measured wear rates in a clinical setting. Thirty-one patients with a total hip replacement were measured with RSA, the gold standard for clinical wear measurements. The reference examination was done within 1 week of the operation and the follow-up examinations were done at 1, 2 and 5 years. Conventional pelvic X-rays were taken on the same day. The contact stress distribution in the hip joint was determined by the computer program HIPSTRESS. The procedure for the determination of the hip joint contact stress distribution is based on the mathematical model of the resultant hip force in the one-legged stance and the mathematical model of the contact stress distribution. The model for the force requires as input data, several geometrical parameters of the hip and the body weight, while the model for stress requires as input data, the magnitude and direction of the resultant hip force. The stress distribution is presented by the peak stress-the maximal value of stress on the weight-bearing area (p(max)) and also by the peak stress calculated with respect to the body weight (p(max)/W(B)) which gives the effect of hip geometry. Visualization of the relations between predicted values by the model and the wear at different points in the follow-up was done using scatterplots. Correlations were expressed as Pearson r values. The predicted p(max) and wear were clearly correlated in the first year post-operatively (r = 0.58, p = 0.002), while this correlation is weaker after 2 years (r = 0.19, p = 0.337) and 5 years (r = 0.24, p = 0.235). The wear values at 1, 2 and 5 years post-operatively correlate with each other in the way that is expected considering the wear velocity curve of the whole group. The correlation between the predicted p(max) values of two observers who were blinded for each other's results was very good (r = 0.93, p < 0.001). We conclude that the biomechanical model used in this paper provides a scientific foundation for the development of a new way of constructing preoperative biomechanical plans for total hip replacements.

  1. 2017 American College of Rheumatology/American Association of Hip and Knee Surgeons Guideline for the Perioperative Management of Antirheumatic Medication in Patients With Rheumatic Diseases Undergoing Elective Total Hip or Total Knee Arthroplasty.

    PubMed

    Goodman, Susan M; Springer, Bryan; Guyatt, Gordon; Abdel, Matthew P; Dasa, Vinod; George, Michael; Gewurz-Singer, Ora; Giles, Jon T; Johnson, Beverly; Lee, Steve; Mandl, Lisa A; Mont, Michael A; Sculco, Peter; Sporer, Scott; Stryker, Louis; Turgunbaev, Marat; Brause, Barry; Chen, Antonia F; Gililland, Jeremy; Goodman, Mark; Hurley-Rosenblatt, Arlene; Kirou, Kyriakos; Losina, Elena; MacKenzie, Ronald; Michaud, Kaleb; Mikuls, Ted; Russell, Linda; Sah, Alexander; Miller, Amy S; Singh, Jasvinder A; Yates, Adolph

    2017-08-01

    This collaboration between the American College of Rheumatology and the American Association of Hip and Knee Surgeons developed an evidence-based guideline for the perioperative management of antirheumatic drug therapy for adults with rheumatoid arthritis (RA), spondyloarthritis (SpA) including ankylosing spondylitis and psoriatic arthritis, juvenile idiopathic arthritis (JIA), or systemic lupus erythematosus (SLE) undergoing elective total hip (THA) or total knee arthroplasty (TKA). A panel of rheumatologists, orthopedic surgeons specializing in hip and knee arthroplasty, and methodologists was convened to construct the key clinical questions to be answered in the guideline. A multi-step systematic literature review was then conducted, from which evidence was synthesized for continuing versus withholding antirheumatic drug therapy and for optimal glucocorticoid management in the perioperative period. A Patient Panel was convened to determine patient values and preferences, and the Grading of Recommendations Assessment, Development and Evaluation methodology was used to rate the quality of evidence and the strength of recommendations, using a group consensus process through a convened Voting Panel of rheumatologists and orthopedic surgeons. The strength of the recommendation reflects the degree of certainty that benefits outweigh harms of the intervention, or vice versa, considering the quality of available evidence and the variability in patient values and preferences. The guideline addresses the perioperative use of antirheumatic drug therapy including traditional disease-modifying antirheumatic drugs, biologic agents, tofacitinib, and glucocorticoids in adults with RA, SpA, JIA, or SLE who are undergoing elective THA or TKA. It provides recommendations regarding when to continue, when to withhold, and when to restart these medications, and the optimal perioperative dosing of glucocorticoids. The guideline includes 7 recommendations, all of which are conditional and based on low- or moderate-quality evidence. This guideline should help decision-making by clinicians and patients regarding perioperative antirheumatic medication management at the time of elective THA or TKA. These conditional recommendations reflect the paucity of high-quality direct randomized controlled trial data. © 2017, American College of Rheumatology.

  2. Effect of Body Mass Index on Complications and Reoperations After Total Hip Arthroplasty.

    PubMed

    Wagner, Eric R; Kamath, Atul F; Fruth, Kristin M; Harmsen, William S; Berry, Daniel J

    2016-02-03

    High body mass index (BMI) is associated with increased rates of complications after total hip arthroplasty. Studies to date have evaluated risk mainly as a dichotomous variable according to BMI thresholds. The purpose of this paper was to characterize the risk of complications and implant survival according to BMI as a continuous variable. Using prospectively collected data from our institutional total joint registry, we analyzed 21,361 consecutive hips (17,774 patients) treated with primary total hip arthroplasty between 1985 and 2012 at a single institution. The average BMI at the time of surgery was 28.7 kg/m(2) (range, 15 to 69 kg/m(2)). Estimates of revision surgery and common complications associated with BMI were analyzed using the Kaplan-Meier method of assessing survivorship, with associations of outcomes assessed using a Cox model. Utilizing smoothing spline parameterization, we found that reoperation (p < 0.001) and implant revision or removal rates (p = 0.002) increased with increasing BMI. Increasing BMI was associated with increased rates of early hip dislocation (p = 0.02), wound infection, and, most strikingly, deep periprosthetic infection (a hazard ratio of 1.09 per unit of BMI >25 kg/m(2); p < 0.001). However, we found no association between increasing BMI and any revision for mechanical failure of the implant or between increasing BMI and revision for aseptic implant loosening. There was an inverse correlation between increasing BMI and risk of revision for bearing wear. The rates of reoperation, implant revision or removal, and common complications after total hip arthroplasty were strongly associated with BMI. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  3. Formal Physical Therapy After Total Hip Arthroplasty Is Not Required: A Randomized Controlled Trial.

    PubMed

    Austin, Matthew S; Urbani, Brian T; Fleischman, Andrew N; Fernando, Navin D; Purtill, James J; Hozack, William J; Parvizi, Javad; Rothman, Richard H

    2017-04-19

    The value of formal physical therapy after total hip arthroplasty is unknown. With substantial changes that have occurred in surgical and anesthesia techniques, self-directed therapy may be efficacious in restoring function to patients undergoing total hip arthroplasty. We conducted a single-center, randomized trial of 120 patients undergoing primary, unilateral total hip arthroplasty who were eligible for direct home discharge. The experimental group followed a self-directed home exercise program for 10 weeks. The control group received the standard protocol for physical therapy that included in-home visits with a physical therapist for the first 2 weeks followed by formal outpatient physical therapy for 8 weeks. Functional outcomes were measured using validated instruments including the Harris hip score (HHS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the Short Form-36 Health Survey (SF-36) preoperatively, at 1 month postoperatively, and at 6 to 12 months postoperatively. Of 120 randomized patients, 108 were included in the final analysis. Ten patients (19%) were randomized to unsupervised home exercise and 20 patients (37%) were randomized to formal outpatient therapy crossed over between groups. There was no significant difference in any of the measured functional outcomes between patients receiving formal therapy (n = 54) and those participating in unsupervised home exercise (n = 54) at any time point (HHS, p = 0.82; WOMAC, p = 0.80; and SF-36 physical health, p = 0.90). This randomized trial suggests that unsupervised home exercise is both safe and efficacious for a majority of patients undergoing total hip arthroplasty, and formal physical therapy may not be required. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  4. The cost analysis of cemented versus cementless total hip replacement operations on the NHS.

    PubMed

    Kallala, R; Anderson, P; Morris, S; Haddad, F S

    2013-07-01

    In a time of limited resources, the debate continues over which types of hip prosthesis are clinically superior and more cost-effective. Orthopaedic surgeons increasingly need robust economic evidence to understand the full value of the operation, and to aid decision making on the 'package' of procedures that are available and to justify their practice beyond traditional clinical preference. In this paper we explore the current economic debate about the merits of cemented and cementless total hip replacement, an issue that continues to divide the orthopaedic community.

  5. Simulated studies of wear and friction in total hip prosthesis components with various ball sizes and surface finishes

    NASA Technical Reports Server (NTRS)

    Swikert, M. A.; Johnson, R. L.

    1976-01-01

    Experiments were conducted on a newly designed total hip joint simulator. The apparatus closely simulates the complex motions and loads of the human hip in normal walking. The wear and friction of presently used appliance configurations and materials were determined. A surface treatment of the metal femoral ball specimens was applied to influence wear. The results of the investigation indicate that wear can be reduced by mechanical treatment of metal femoral ball surfaces. A metallographic examination and surface roughness measurements were made.

  6. The effect of education and supervised exercise vs. education alone on the time to total hip replacement in patients with severe hip osteoarthritis. A randomized clinical trial protocol.

    PubMed

    Jensen, Carsten; Roos, Ewa M; Kjærsgaard-Andersen, Per; Overgaard, Søren

    2013-01-14

    The age- and gender-specific incidence of total hip replacement surgery has increased over the last two decades in all age groups. Recent studies indicate that non-surgical interventions are effective in reducing pain and disability, even at later stages of the disease when joint replacement is considered. We hypothesize that the time to hip replacement can be postponed in patients with severe hip osteoarthritis following participation in a patient education and supervised exercise program when compared to patients receiving patient education alone. A prospective, blinded, parallel-group multi-center trial (2 sites), with balanced randomization [1:1]. Patients with hip osteoarthritis and an indication for hip replacement surgery, aged 40 years and above, will be consecutively recruited and randomized into two treatment groups. The active treatment group will receive 3 months of supervised exercise consisting of 12 sessions of individualized, goal-based neuromuscular training, and 12 sessions of intensive resistance training plus patient education (3 sessions). The control group will receive only patient education (3 sessions). The primary end-point for assessing the effectiveness of the intervention is 12 months after baseline. However, follow-ups will also be performed once a year for at least 5 years. The primary outcome measure is the time to hip replacement surgery measured on a Kaplain-Meier survival curve from time of inclusion. Secondary outcome measures are the five subscales of the Hip disability and Osteoarthritis Outcome Score, physical activity level (UCLA activity score), and patient's global perceived effect. Other measures include pain after exercise, joint-specific adverse events, exercise adherence, general health status (EQ-5D-5L), mechanical muscle strength and performance in physical tests. A cost-effectiveness analysis will also be performed. To our knowledge, this is the first randomized clinical trial comparing a patient education plus supervised exercise program to patient education alone in hip osteoarthritis patients with an indication for surgery on the time to total hip replacement. NCT01697241.

  7. Ultrasound-guided Radiofrequency Lesioning of the Articular Branches of the Femoral Nerve for the Treatment of Chronic Post-arthroplasty Hip Pain.

    PubMed

    Kim, David J; Shen, Shiqian; Hanna, George M

    2017-02-01

    Total hip arthroplasty (THA) is a common surgical treatment for several conditions of the hip. While the majority of patients obtain satisfactory results, many develop chronic post-arthroplasty hip pain that can be difficult to treat. We evaluate the effectiveness of cooled (60°C) radiofrequency lesioning of the articular branches of the femoral nerve (ABFN) as a minimally invasive treatment for patients suffering from chronic post-arthroplasty hip pain. This treatment has never been described previously in this population. Case report. Center for Pain Medicine, Massachusetts General Hospital, Harvard Medical School. A 59-year-old woman with long-standing osteoarthritis of the right hip who underwent primary total hip arthroplasty and presented with chronic post-arthroplasty hip pain Intervention: Cooled (60°C) radiofrequency lesioning of the ABFN under ultrasound guidance Outcome Measure: Functional ability and numeric rating scale (NRS) scores at rest and with activity. Prior to intervention, the patient reported severe disruption in daily activities, sleep, and relationships; NRS scores at rest and with activity were 4/10 and 10/10, respectively. At 4 weeks following intervention, the patient reported significant improvement in functional ability and NRS scores decreased to 1/10 and 2/10, respectively. At 6 months, the patient's NRS scores at rest and with activity were 0/10 and 1/10, respectively. At 24-month follow-up, the patient continued to endorse significant pain relief with NRS scores at rest and with activity of 0 - 1/10 and 1 - 2/10, respectively. There were no side effects or complications including motor weakness, sensory loss, and neuralgias. Although the patient obtained good results from the intervention, the description of the study is from a single case report. Further study is necessary to investigate the widespread use of this technique and its outcomes. Cooled (60°C) radiofrequency lesioning of the ABFN under ultrasound guidance is both an effective and minimally invasive intervention for chronic post-arthroplasty hip pain. Key words: Radiofrequency lesioning, articular branches, femoral nerve, post-arthoplasty, total hip arthoplasty, hip pain, chronic pain.

  8. [Unusual infection complication of total hip arthroplasty].

    PubMed

    Jány, R; Vojtassák, J; Lisý, M; Almási, J

    2005-01-01

    Authors present the case history of a 66-year old patient after repeated reimplantations of the THA with a deep infect caused by a rare aetiological agent (Serratia marcescens) associated with a pyogenic sinus. They describe the disease history, therapeutic procedure, complications associated with the surgery as well as postoperative course after the reimplantation of a customized total hip replacement. In the conclusion they state that in case of an infected total hip arthroplasty the treatment is focused on the salvage of the infection process and preservation of the function of the affected limb. Of essential importance is surgical revision with a radical removal of necrotic tissues and hardware in combination with an intensive parenteral antibiotic administration.

  9. Management of osteonecrosis of the femoral head in children with sickle cell disease: results of conservative and operative treatments at skeletal maturity.

    PubMed

    Mallet, C; Abitan, A; Vidal, C; Holvoet, L; Mazda, K; Simon, A-L; Ilharreborde, B

    2018-02-01

    Sickle cell disease (SCD) is the most common cause of femoral head osteonecrosis (ONFH) during childhood with an overall prevalence of 10%. In children, spontaneous revascularization can occur, as in Legg-Calve-Perthes disease. Consequently, the aim of treatment is to restore proper hip containment to prevent joint arthritis. This is the first study reporting long-term results at skeletal maturity of non-operative and surgical treatments for ONFH in SCD children. All children with ONFH due to SCD were retrospectively reviewed. At initial evaluation, extension of osteonecrosis was radiographically defined using Catterall, lateral pillar Herring and Ficat classifications. Subluxation of the femoral head with Reimers migration index > 30% required surgical treatment including femoral varus osteotomy and/or pelvic osteotomies. Conservative treatment including non-weight bearing and physiotherapy was performed in the remaining cases. Outcomes were assessed at skeletal maturity using the Harris Hip Score (HHS) and the Stulberg classification. Total hip arthroplasty and Stulberg 5 were defined as failures. A total of 25 hips in 17 patients were included (mean follow-up 7.5 years SD 3.4). Mean age at diagnosis was 11.4 years SD 2.9. In all, 15 hips (60%) were classified Catterall 3 and 4 and Herring B and C. A total of 13 patients (52%) underwent surgical treatment. At skeletal maturity, mean HHS was good (81 SD 17), 12 hips (48%) were classified Stulberg 1 and 2, seven hips (28%) were classified Stulberg 3 and 4. Both treatments led to good functional results with 75% of congruent hips at skeletal maturity. IV.

  10. Management of osteonecrosis of the femoral head in children with sickle cell disease: results of conservative and operative treatments at skeletal maturity

    PubMed Central

    Mallet, C.; Abitan, A.; Vidal, C.; Holvoet, L.; Mazda, K.; Simon, A.-L.; Ilharreborde, B.

    2018-01-01

    Abstract Purpose Sickle cell disease (SCD) is the most common cause of femoral head osteonecrosis (ONFH) during childhood with an overall prevalence of 10%. In children, spontaneous revascularization can occur, as in Legg-Calve-Perthes disease. Consequently, the aim of treatment is to restore proper hip containment to prevent joint arthritis. This is the first study reporting long-term results at skeletal maturity of non-operative and surgical treatments for ONFH in SCD children. Methods All children with ONFH due to SCD were retrospectively reviewed. At initial evaluation, extension of osteonecrosis was radiographically defined using Catterall, lateral pillar Herring and Ficat classifications. Subluxation of the femoral head with Reimers migration index > 30% required surgical treatment including femoral varus osteotomy and/or pelvic osteotomies. Conservative treatment including non-weight bearing and physiotherapy was performed in the remaining cases. Outcomes were assessed at skeletal maturity using the Harris Hip Score (HHS) and the Stulberg classification. Total hip arthroplasty and Stulberg 5 were defined as failures. Results A total of 25 hips in 17 patients were included (mean follow-up 7.5 years SD 3.4). Mean age at diagnosis was 11.4 years SD 2.9. In all, 15 hips (60%) were classified Catterall 3 and 4 and Herring B and C. A total of 13 patients (52%) underwent surgical treatment. At skeletal maturity, mean HHS was good (81 SD 17), 12 hips (48%) were classified Stulberg 1 and 2, seven hips (28%) were classified Stulberg 3 and 4. Conclusion Both treatments led to good functional results with 75% of congruent hips at skeletal maturity. Level of Evidence IV PMID:29456754

  11. [The Use of Jumbo Cups in Revision Total Hip Arthroplasty].

    PubMed

    von Roth, Philipp; Wassilew, Georgi I

    2017-10-01

    Extra-large uncemented jumbo cups are among the most common methods of acetabular revision. Jumbo cups do not contribute to bone stock restoration, and in the case of a subsequent revision, an even larger bone defect is to be expected. Thus, understanding long-term survival is essential. The present article discusses the literature relevant to this topic and addresses technical and implant-specific characteristics of jumbo cups. In summary, jumbo cups show an acceptable long-term survival rate, with aseptic loosening as the most common reason for revision and dislocation being the most common complication. Through the development of alternative revision systems, jumbo cups have lost their importance in today's practice. However, they can serve as a benchmark for studies of newer technologies in revision total hip arthroplasty. Georg Thieme Verlag KG Stuttgart · New York.

  12. Survivorship analysis of failure pattern after revision total hip arthroplasty.

    PubMed

    Retpen, J B; Varmarken, J E; Jensen, J S

    1989-12-01

    Failure, defined as established indication for or performed re-revision of one or both components, was analyzed using survivorship methods in 306 revision total hip arthroplasties. The longevity of revision total hip arthroplasties was inferior to that of previously reported primary total hip arthroplasties. The overall survival curve was two-phased, with a late failure period associated with aseptic loosening of one or both components and an early failure period associated with causes of failure other than loosening. Separate survival curves for aseptic loosening of femoral and acetabular components showed late and almost simultaneous decline, but with a tendency toward a higher rate of failure for the femoral component. No differences in survival could be found between the Stanmore, Lubinus standard, and Lubinus long-stemmed femoral components. A short interval between the index operation and the revision and intraoperative and postoperative complications were risk factors for early failure. Young age was a risk factor for aseptic loosening of the femoral component. Intraoperative fracture of the femoral shaft was not a risk factor for secondary loosening. No difference in survival was found between primary cemented total arthroplasty and primary noncemented hemiarthroplasty.

  13. Usefulness of postoperative hip irradiation in the prevention of heterotopic bone formation in a high risk group of patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacLennan, I.; Keys, H.M.; Evarts, C.M.

    1984-01-01

    Heterotopic ossification is a complication of total hip arthroplasty in 14 to 30% of patients. Significant functional impairment will occur in up to 28% of patients with ectopic bone. The high risk group includes those with preexisting heterotopic bone in either hip, those suffering from hypertrophic osteoarthritis or ankylosing spondylitis and patients who have had multiple procedures on the hip. Fifty-eight patients (67 hips) were irradiated after surgical removal of ectopic bone (53 hips) or received radiation prophylaxis of heterotopic ossification (14 hips). Ninety-five percent of patients had either no bone visible or insignificant amounts of ectopic bone visible onmore » postoperative hip X-rays. Only 5% of patients showed significant persistence of ectopic bone. Postoperative hip function was dramatically improved compared to preoperative function in all patients treated. The importance of early commencement of irradiation is emphasized.« less

  14. Dynamic Hip Kinematics During the Golf Swing After Total Hip Arthroplasty.

    PubMed

    Hara, Daisuke; Nakashima, Yasuharu; Hamai, Satoshi; Higaki, Hidehiko; Ikebe, Satoru; Shimoto, Takeshi; Yoshimoto, Kensei; Iwamoto, Yukihide

    2016-07-01

    Although most surgeons allow their patients to play golf after total hip arthroplasty (THA), the effect on the implant during the golf swing is still unclear. To evaluate hip kinematics during the golf swing after THA. Descriptive laboratory study. Eleven hips in 9 patients who underwent primary THA were analyzed. All patients were right-handed recreational golfers, and these 11 hips included 6 right hips and 5 left hips. Periodic radiographic images of the golf swing were taken using a flat-panel x-ray detector. Movements of the hip joint and components were assessed using 3-dimensional-to-2-dimensional model-to-image registration techniques. Liner-to-neck contact and translation of the femoral head with respect to the acetabular cup (cup-head translation) were examined. Hip kinematics, orientation of components, and maximum cup-head translation were compared between patients with and without liner-to-neck contact. On average, the golf swing produced approximately 50° of axial rotation in both lead and trail hips. Liner-to-neck contact was observed in 4 hips with elevated rim liners (2 lead hips and 2 trail hips) at maximum external rotation. Neither bone-to-bone nor bone-to-implant contact was observed at any phases of the golf swing in any of the hips. Four hips with liner-to-neck contact had significantly larger maximum external rotation (37.9° ± 7.0° vs 20.6° ± 9.9°, respectively; P = .01) and more cup anteversion (26.5° ± 6.1° vs 10.8° ± 8.9°, respectively; P = .01) than hips without liner-to-neck contact. No significant differences between hips with and without contact were found for cup inclination (42.0° ± 2.5° vs 38.1° ± 5.5°, respectively; P = .22), combined anteversion (45.3° ± 8.9° vs 51.4° ± 7.9°, respectively; P = .26), or maximum cup-head translation (1.3 ± 0.3 mm vs 1.5 ± 0.4 mm, respectively; P = .61). In this analysis, the golf swing did not produce excessive hip rotation or cup-head translation in any hips. However, liner-to-neck contact during the golf swing was observed in 36% of the hips, with unknown effects on the long-term results. Golf is an admissible sport after THA because dynamic hip stability was observed. However, the implant position, especially cup anteversion and the use of elevated rim liners, promoted liner-to-neck contact. © 2016 The Author(s).

  15. A comparison of regional and general anaesthesia for total replacement of the hip or knee: a meta-analysis.

    PubMed

    Hu, S; Zhang, Z-Y; Hua, Y-Q; Li, J; Cai, Z-D

    2009-07-01

    We performed a meta-analysis to evaluate the relative efficacy of regional and general anaesthesia in patients undergoing total hip or knee replacement. A comprehensive search for relevant studies was performed in PubMed (1966 to April 2008), EMBASE (1969 to April 2008) and the Cochrane Library. Only randomised studies comparing regional and general anaesthesia for total hip or knee replacement were included. We identified 21 independent, randomised clinical trials. A random-effects model was used to calculate all effect sizes. Pooled results from these trials showed that regional anaesthesia reduces the operating time (odds ratio (OR) -0.19; 95% confidence interval (CI) -0.33 to -0.05), the need for transfusion (OR 0.45; 95% CI 0.22 to 0.94) and the incidence of thromboembolic disease (deep-vein thrombosis OR 0.45, 95% CI 0.24 to 0.84; pulmonary embolism OR 0.46, 95% CI 0.29 to 0.80). Regional anaesthesia therefore seems to improve the outcome of patients undergoing total hip or knee replacement.

  16. Basic Science Considerations in Primary Total Hip Replacement Arthroplasty

    PubMed Central

    Mirza, Saqeb B; Dunlop, Douglas G; Panesar, Sukhmeet S; Naqvi, Syed G; Gangoo, Shafat; Salih, Saif

    2010-01-01

    Total Hip Replacement is one of the most common operations performed in the developed world today. An increasingly ageing population means that the numbers of people undergoing this operation is set to rise. There are a numerous number of prosthesis on the market and it is often difficult to choose between them. It is therefore necessary to have a good understanding of the basic scientific principles in Total Hip Replacement and the evidence base underpinning them. This paper reviews the relevant anatomical and biomechanical principles in THA. It goes on to elaborate on the structural properties of materials used in modern implants and looks at the evidence base for different types of fixation including cemented and uncemented components. Modern bearing surfaces are discussed in addition to the scientific basis of various surface engineering modifications in THA prostheses. The basic science considerations in component alignment and abductor tension are also discussed. A brief discussion on modular and custom designs of THR is also included. This article reviews basic science concepts and the rationale underpinning the use of the femoral and acetabular component in total hip replacement. PMID:20582240

  17. Cell therapy versus simultaneous contralateral decompression in symptomatic corticosteroid osteonecrosis: a thirty year follow-up prospective randomized study of one hundred and twenty five adult patients.

    PubMed

    Hernigou, Philippe; Dubory, Arnaud; Homma, Yasuhiro; Guissou, Isaac; Flouzat Lachaniette, Charles Henri; Chevallier, Nathalie; Rouard, Hélène

    2018-05-09

    Symptomatic osteonecrosis related to corticosteroids has a high risk of progression to collapse in absence of treatment. The purposes of this study were to evaluate the results of autologous bone marrow grafting of the symptomatic hip in adult patients with osteonecrosis and to compare the results with core decompression alone in the contralateral symptomatic hip. A total of 125 consecutive patients (78 males and 47 females) with bilateral osteonecrosis (ON) and who had both hips symptomatic and at the same stage on each side (stage I or II) were included in this study from 1988 to 1998. The volume of osteonecrosis was measured with MRI in both hips; the smaller size ON was treated with core decompression, and the contralateral hip with the larger ON was treated with percutaneous mesenchymal cell (MSC) injection obtained from bone marrow concentration. The average total number of MSCs (counted as number of colony forming units-fibroblast) injected in each hip was 90,000 ± 25,000 cells (range 45,000 to 180,000 cells). At the most recent FU (average 25 years after the first surgery, range 20 to 30 years), among the 250 hips included in the study, 35 hips (28%) had collapsed at the most recent follow-up after bone marrow grafting, and 90 (72%) after core decompression (CD). Ninety-five hips (76%) in the CD group underwent total hip replacement and 30 hips (24%) in the bone marrow graft group (p < 0.0001). Hips undergoing only CD were approximately three times more likely to undergo a primary THA (odds ratio: 10.0278; 95% CI: 5.6117 to 17.9190; p < 0.0001) as compared with hips undergoing an initial bone marrow grafting. For the 90 hips treated with bone marrow injection and without collapse, the mean volume of repair evaluated by MRI at the most recent follow-up was 16.4 cm 3 (range 12 to 21 cm 3 ) corresponding to a decrease of the pre-operative average volume from 22.4 cm 3 (range 35-15 cm 3 ) to 6 cm 3 (range 12-0 cm 3 ); as percentage of the volume of the femoral head, the decrease moved from 44.8 to 12%. Core decompression with bone marrow injection improved the outcome of the disease as compared with core decompression alone in the same patient.

  18. Effects of the Length of Stay on the Cost of Total Knee and Total Hip Arthroplasty from 2002 to 2013.

    PubMed

    Molloy, Ilda B; Martin, Brook I; Moschetti, Wayne E; Jevsevar, David S

    2017-03-01

    Utilization of total knee and hip arthroplasty has greatly increased in the past decade in the United States; these are among the most expensive procedures in patients with Medicare. Advances in surgical techniques, anesthesia, and care pathways decrease hospital length of stay. We examined how trends in hospital cost were altered by decreases in length of stay. Procedure, demographic, and economic data were collected on 6.4 million admissions for total knee arthroplasty and 2.8 million admissions for total hip arthroplasty from 2002 to 2013 using the National (Nationwide) Inpatient Sample, a component of the Healthcare Cost and Utilization Project. Trends in mean hospital costs and their association with length of stay were estimated using inflation-adjusted, survey-weighted generalized linear regression models, controlling for patient demographic characteristics and comorbidity. From 2002 to 2013, the length of stay decreased from a mean time of 4.06 to 2.97 days for total knee arthroplasty and from 4.06 to 2.75 days for total hip arthroplasty. During the same time period, the mean hospital cost for total knee arthroplasty increased from $14,988 (95% confidence interval [CI], $14,927 to $15,049) in 2002 to $22,837 (95% CI, $22,765 to $22,910) in 2013 (an overall increase of $7,849 or 52.4%). The mean hospital cost for total hip arthroplasty increased from $15,792 (95% CI, $15,706 to $15,878) in 2002 to $23,650 (95% CI, $23,544 to $23,755) in 2013 (an increase of $7,858 or 49.8%). If length of stay were set at the 2002 mean, the growth in cost for total knee arthroplasty would have been 70.8% instead of 52.4% as observed, and the growth in cost for total hip arthroplasty would have been 67.4% instead of 49.8% as observed. Hospital costs for joint replacement increased from 2002 to 2013, but were attenuated by reducing inpatient length of stay. With demographic characteristics showing an upward trend in the utilization of joint arthroplasty, including a shift toward younger population groups, reduction in length of stay remains an important target for procedure-level cost containment under emerging payment models.

  19. Measurement considerations on examiner-dependent factors in the ultrasound assessment of developmental dysplasia of the hip.

    PubMed

    Kolb, Alexander; Benca, Emir; Willegger, Madeleine; Puchner, Stephan E; Windhager, Reinhard; Chiari, Catharina

    2017-06-01

    The standardized sonographic hip screening according to Graf has increased reliability and comparability of measurements in the screening of developmental dysplasia of the hip (DDH). However, examiner dependent factors have been discussed to influence sonographic measurements. The objectives of this study were to examine the tolerance of the transducer positioning and to analyse the impact of transducer inclinations on Graf's hip grading system. Twenty-four hips in consecutive newborns were screened sonographically in combination with an optoelectronic motion capture system to trace transducer positions in space. Subsequently five defined inclinations of the transducer relative to Graf's neutral transducer position were analysed, giving a total of 144 sonographic images. We found a permissible transducer inclination in the axial plane of 8.8° to anterior and 8.1° to posterior. In the frontal plane we found a permissible inclination of 15.4° to caudal and 7.2° to cranial. The impact on the α-angle was significant for posterior-cranial (p < 0.001), cranial (p = 0.009), and caudal (p < 0.001) inclined transducer positions. The effect on the results according to Graf's grading system was significant for the caudal inclination of the transducer position (p < 0.001). Our findings show that the standardized plane defined by Graf's criteria allows notable inclinations of the transducer positions. Transducer inclinations show an impact on measurement results, which are clinically relevant. Those effects cannot be ruled out using Graf's ultrasound criteria alone. The examiner should pay attention to avoid transducer inclinations in the frontal plane and a combination of posterior and cranial inclination.

  20. Assessment of Accuracy and Reliability in Acetabular Cup Placement Using an iPhone/iPad System.

    PubMed

    Kurosaka, Kenji; Fukunishi, Shigeo; Fukui, Tomokazu; Nishio, Shoji; Fujihara, Yuki; Okahisa, Shohei; Takeda, Yu; Daimon, Takashi; Yoshiya, Shinichi

    2016-07-01

    Implant positioning is one of the critical factors that influences postoperative outcome of total hip arthroplasty (THA). Malpositioning of the implant may lead to an increased risk of postoperative complications such as prosthetic impingement, dislocation, restricted range of motion, polyethylene wear, and loosening. In 2012, the intraoperative use of smartphone technology in THA for improved accuracy of acetabular cup placement was reported. The purpose of this study was to examine the accuracy of an iPhone/iPad-guided technique in positioning the acetabular cup in THA compared with the reference values obtained from the image-free navigation system in a cadaveric experiment. Five hips of 5 embalmed whole-body cadavers were used in the study. Seven orthopedic surgeons (4 residents and 3 senior hip surgeons) participated in the study. All of the surgeons examined each of the 5 hips 3 times. The target angle was 38°/19° for operative inclination/anteversion angles, which corresponded to radiographic inclination/anteversion angles of 40°/15°. The simultaneous assessment using the navigation system showed mean±SD radiographic alignment angles of 39.4°±2.6° and 16.4°±2.6° for inclination and anteversion, respectively. Assessment of cup positioning based on Lewinnek's safe zone criteria showed all of the procedures (n=105) achieved acceptable alignment within the safe zone. A comparison of the performances by resident and senior hip surgeons showed no significant difference between the groups (P=.74 for inclination and P=.81 for anteversion). The iPhone/iPad technique examined in this study could achieve acceptable performance in determining cup alignment in THA regardless of the surgeon's expertise. [Orthopedics. 2016; 39(4):e621-e626.]. Copyright 2016, SLACK Incorporated.

  1. Diet-quality scores and risk of hip fractures in elderly urban Chinese in Guangdong, China: a case-control study.

    PubMed

    Zeng, F F; Xue, W Q; Cao, W T; Wu, B H; Xie, H L; Fan, F; Zhu, H L; Chen, Y M

    2014-08-01

    This case-control study compared the associations of four widely used diet-quality scoring systems with the risk of hip fractures and assessed their utility in elderly Chinese. We found that individuals avoiding a low-quality diet have a lower risk of hip fractures in elderly Chinese. Few studies examined the associations of diet-quality scores on bone health, and no studies were available in Asians and compared their validity and utility in a study. We assessed the associations and utility of four widely used diet-quality scoring systems with the risk of hip fractures. A case-control study of 726 patients with hip fractures (diagnosed within 2 weeks) aged 55-80 years and 726 age- (within 3 years) and gender-matched controls was conducted in Guangdong, China (2009-2013). Dietary intake was assessed using a 79-item food frequency questionnaire with face-to-face interviews, and the Healthy Eating Index-2005 (HEI-2005, 12 items), the alternate Healthy Eating Index (aHEI, 8 items), the Diet Quality Index-International (DQI-I, 17 items), and the alternate Mediterranean Diet Score (aMed, 9 items) (the simplest one) were calculated. All greater values of the diet-quality scores were significantly associated with a similar decreased risk of hip fractures (all p trends <0.001). The multivariate-adjusted odds ratios (ORs) and 95% confidential intervals (95% CIs) comparing the extreme groups of diet-quality scores were 0.29 (0.18, 0.46) (HEI-2005), 0.20 (0.12, 0.33) (aHEI), 0.25 (0.16, 0.39) (DQI-I), and 0.28 (0.18, 0.43) (aMed) in total subjects; and the corresponding ORs ranged from 0.04 to 0.27 for men and from 0.26 to 0.44 for women (all p trends <0.05), respectively. Avoiding a low-quality diet is associated with a lower risk of hip fractures, and the aMed score is the best scoring system due to its equivalent performance and simplicity for the user.

  2. Evidence to suggest that women's sexual behavior is influenced by hip width rather than waist-to-hip ratio.

    PubMed

    Simpson, Victoria J; Brewer, Gayle; Hendrie, Colin A

    2014-10-01

    Waist-to-hip ratio (WHR) is an important ornament display that signals women's health and fertility. Its significance derives from human development as a bipedal species. This required fundamental changes to hip morphology/musculature to accommodate the demands of both reproduction and locomotion. The result has been an obstetric dilemma whereby women's hips are only just wide enough to allow the passage of an infant. Childbirth therefore poses a significant hip width related threat to maternal mortality/risk of gynecological injury. It was predicted that this would have a significant influence on women's sexual behavior. To investigate this, hip width and WHR were measured in 148 women (M age = 20.93 + 0.17 years) and sexual histories were recorded via questionnaire. Data revealed that hip width per se was correlated with total number of sexual partners, total number of one night stands, percentage of sexual partners that were one night stands, number of sexual partners within the context of a relationship per year sexually active, and number of one night stands per year sexually active. By contrast, WHR was not correlated with any of these measures. Further analysis indicated that women who predominantly engaged in one night stand behavior had wider hips than those who did not. WHR was again without effect in this context. Women's hip morphology has a direct impact on their risk of potentially fatal childbirth related injury. It is concluded that when they have control over this, women's sexual behavior reflects this risk and is therefore at least in part influenced by hip width.

  3. Hip arthroscopy in patients with recurrent pain following Bernese periacetabular osteotomy for acetabular dysplasia: operative findings and clinical outcomes

    PubMed Central

    Cvetanovich, Gregory L.; Heyworth, Benton E.; Murray, Kerri; Yen, Yi-Meng; Kocher, Mininder S.; Millis, Michael B.

    2015-01-01

    To report the operative findings and outcomes of hip arthroscopy for recurrent pain following periacetabular osteotomy (PAO) for acetabular dysplasia. A departmental database was used to identify patients who underwent hip arthroscopy following PAO between 2000 and 2009. Demographic data, arthroscopic findings, functional outcome scores and patient satisfaction were analysed. Of 556 PAO patients, 17 hips in 16 patients (3.1%) underwent post-PAO hip arthroscopy. Mean age at PAO was 23.8 years, and mean age at arthroscopy was 27.0 years. Common hip arthroscopy findings included labral tears (13 hips, 81.3%), significant (≥grade 2) chondral changes (12 hips, 75%), cam impingement (7 hips, 43.8%) and pincer impingement (6 hips, 37.5%). At mean follow-up 2.8 years after arthroscopy, additional procedures had been performed in six hips (37.5%), including total hip arthroplasty in one hip. Post-PAO arthroscopy questionnaire revealed 85.7% of patients with improved hip pain, 57.1% improved hip stiffness and 57.1% improved hip function. There was no significant difference in functional outcome measures. Common post-PAO hip arthroscopy findings include labral tears, chondral changes and femoroacetabular impingement. Many patients reported subjective hip improvement from post-PAO arthroscopy, but hip outcome scores were unchanged and one-third of patients had further surgery. PMID:27011852

  4. Patient-oriented functional results of total femoral endoprosthetic reconstruction following oncologic resection.

    PubMed

    Jones, Kevin B; Griffin, Anthony M; Chandrasekar, Coonoor R; Biau, David; Babinet, Antoine; Deheshi, Benjamin; Bell, Robert S; Grimer, Robert J; Wunder, Jay S; Ferguson, Peter C

    2011-11-01

    Functional outcomes following oncologic total femoral endoprosthetic reconstruction (TFR) are lacking. We compared patient-oriented functional results of TFRs to proximal femur and distal femur reconstructions (PFR and DFR). We also compared function and complications with regard to knee and hip componentry. Fifty-four TFR patients were identified from three institutional prospective databases. Forty-one had fixed- and 13 had rotating-hinge knees, 37 hemiarthroplasty and 17 total hip arthroplasty componentry. Toronto Extremity Salvage Scores (TESS) for n = 27 were compared between groups and to cohorts of PFR (n = 31) and DFR (n = 85) patients using the Mann-Whitney U-test. Follow-up averaged 4 years. Mechanical complications included five hip dislocations and one femoral malrotation. Four dislocations were in fixed-hinge implants, all in those lacking abductor reattachment. TESS averaged 69.3 ± 17.8, statistically decreased from DFR (P = 0.002) and PFR patients (P = 0.036). No significant differences were detected between patients in the fixed-hinge (n = 18) and rotating-hinge (n = 9) groups (P = 0.944), or total hip (n = 8) and hemiarthroplasty (n = 19) groups (P = 0.633). TFR is reserved for extreme cases of limb salvage, portending a poor prognosis overall. Function reflects additive impairments from PFR and DFR. TFR outcomes differ little with rotating- or fixed-hinge, total hip or hemiarthroplasty implants. Copyright © 2011 Wiley Periodicals, Inc.

  5. Extended application of WISH type S-form hip brace for patients with bilateral painful hip osteoarthritis: report of two cases.

    PubMed

    Sato, Takahisa; Yamaji, Takehiko; Inose, Hideyuki; Sato, Ena; Yoshikawa, Ayako; Usuda, Shigeru; Watanabe, Hideomi

    2009-06-01

    Dynamic lateral instability of the femoral head develops in patients with osteoarthritis (OA) of the hip. Recently we have developed a hip brace, called the WISH-type hip brace, and showed successful response of the patients quantitatively. However, a negligible effect was observed in patients with bilateral involvement. Here, we extended the application of the WISH-type hip brace for two patients with bilateral OA joints. The resultant WISH-type hip brace with two S-form portions for bilateral thighs provided good recovery in hip function. Interestingly Timed Up & Go (TUG) test performed for one patient revealed a positive effect of the brace on the functional mobility. To the best of our knowledge, this is the first report elucidating the therapeutic effect of brace therapy with bilateral hip stabilization from hip functional and functional mobility points of view. Application of the present brace should be taken into account for patients with painful bilateral hip OA before easy application of invasive surgery such as total hip arthroplasty.

  6. UEFA injury study: a prospective study of hip and groin injuries in professional football over seven consecutive seasons.

    PubMed

    Werner, J; Hägglund, M; Waldén, M; Ekstrand, J

    2009-12-01

    Groin injury is a common injury in football and a complicated area when it comes to diagnosis and therapy. There is a lack of comprehensive epidemiological data on groin injuries in professional football. To investigate the incidence, pattern and severity of hip and groin injuries in professional footballers over seven consecutive seasons. Prospective cohort study. European professional football. During the 2001/2 to 2007/8 seasons, between nine and 17 clubs per season (23 clubs in total) were investigated, accounting for 88 club seasons in total. Time loss injuries and individual exposure during club and national team training sessions and matches were recorded. Injury incidence. A total of 628 hip/groin injuries were recorded, accounting for 12-16% of all injuries per season. The total injury incidence was 1.1/1000 h (3.5/1000 match hours vs 0.6/1000 training hours, p<0.001) and was consistent over the seasons studied. Eighteen different diagnostic entities were registered, adductor (n = 399) and iliopsoas (n = 52) related injuries being the most common. More than half of the injuries (53%) were classified as moderate or severe (absence of more than a week), the mean absence per injury being 15 days. Reinjuries accounted for 15% of all registered injuries. In the 2005/6 to 2007/8 seasons, 41% of all diagnoses relied solely on clinical examination. Hip/groin injuries are common in professional football, and the incidence over consecutive seasons is consistent. Hip/groin injuries are associated with long absences. Many hip/groin diagnoses are based only on clinical examination.

  7. Increased Long-Term Cardiovascular Risk After Total Hip Arthroplasty

    PubMed Central

    Gordon, Max; Rysinska, Agata; Garland, Anne; Rolfson, Ola; Aspberg, Sara; Eisler, Thomas; Garellick, Göran; Stark, André; Hailer, Nils P.; Sköldenberg, Olof

    2016-01-01

    Abstract Total hip arthroplasty is a common and important treatment for osteoarthritis patients. Long-term cardiovascular effects elicited by osteoarthritis or the implant itself remain unknown. The purpose of the present study was to determine if there is an increased risk of late cardiovascular mortality and morbidity after total hip arthroplasty surgery. A nationwide matched cohort study with data on 91,527 osteoarthritis patients operated on, obtained from the Swedish Hip Arthroplasty Register. A control cohort (n = 270,688) from the general Swedish population was matched 1:3 to each case by sex, age, and residence. Mean follow-up time was 10 years (range, 7–21). The exposure was presence of a hip replacement for more than 5 years. The primary outcome was cardiovascular mortality after 5 years. Secondary outcomes were total mortality and re-admissions due to cardiovascular events. During the first 5 to 9 years, the arthroplasty cohort had a lower cardiovascular mortality risk compared with the control cohort. However, the risk in the arthroplasty cohort increased over time and was higher than in controls after 8.8 years (95% confidence interval [CI] 7.0–10.5). Between 9 and 13 years postoperatively, the hazard ratio was 1.11 (95% CI 1.05–1.17). Arthroplasty patients were also more frequently admitted to hospital for cardiovascular reasons compared with controls, with a rate ratio of 1.08 (95% CI 1.06–1.11). Patients with surgically treated osteoarthritis of the hip have an increased risk of cardiovascular morbidity and mortality many years after the operation when compared with controls. PMID:26871792

  8. 3D printing technology used in severe hip deformity.

    PubMed

    Wang, Shanshan; Wang, Li; Liu, Yan; Ren, Yongfang; Jiang, Li; Li, Yan; Zhou, Hao; Chen, Jie; Jia, Wenxiao; Li, Hui

    2017-09-01

    This study was designed to assess the use of a 3D printing technique in total hip arthroplasty (THA) for severe hip deformities, where new and improved approaches are needed. THAs were performed from January 2015 to December 2016. Bioprosthesis artificial hip joints were used in both conventional and 3D printing hip arthroplasties. A total of 74 patients (57 cases undergoing conventional hip replacements and 17 undergoing 3D printing hip replacements) were followed-up for an average of 24 months. The average age of the patients was 62.7 years. Clinical data between the patients treated with different approaches were compared. Results showed that the time to postoperative weight bearing and the Harris scores of the patients in the 3D printing group were better than those for patients in the conventional hip replacement group. Unfortunately, the postoperative infection and loosening rates were higher in the 3D printing group. However, there were no significant differences in femoral neck anteversion, neck shaft, acetabular or sharp angles between ipsilateral and contralateral sides in the 3D printing group (P>0.05). The femoral neck anteversion angle was significantly different between the two sides in the conventional hip replacement group (P<0.05). Based on these results, we suggest that the 3D printing approach provides a better short-term curative effect that is more consistent with the physiological structure and anatomical characteristics of the patient, and we anticipate that its use will help improve the lives of many patients.

  9. Cementless total hip arthroplasty with ceramic-on-ceramic bearing in patients younger than 45 years with femoral-head osteonecrosis

    PubMed Central

    Choi, Yoowang; Kim, Jun-Shik

    2009-01-01

    Despite improvements in the quality of alumina ceramics, osteolysis has been reported anecdotally after total hip arthroplasty (THA) with use of a contemporary alumina-on-alumina ceramic bearing. The purpose of this study was to evaluate the clinical and radiographic outcomes of THA using alumina-on-alumina ceramic bearing and to determine osteolysis using radiographs and computed tomographic (CT) scans in young patients. Consecutive primary cementless THA using alumina-on-alumina ceramic bearing were performed in 64 patients (93 hips) who were younger than 45 years of age with femoral-head osteonecrosis. There were 55 men (84 hips) and nine women (nine hips). Average age was 38.2 (range 24–45) years. Average follow-up was 11.1 (range 10–13) years. Preoperative Harris Hip Score was 52.9 (range 22–58) points, which improved to 96 (range 85−100) points at the final follow-up examination. Two of 93 hips (2%) had clicking or squeaking sound. No hip had revision or aseptic loosening. Radiographs and CT scans demonstrated that no acetabular or femoral osteolysis was detected in any hip at the latest follow-up. Contemporary cementless acetabular and femoral components with alumina-on-alumina ceramic bearing couples function well with no osteolysis at a ten year minimum and average of 11.1-year follow-up in this series of young patients with femoral-head osteonecrosis. PMID:19784647

  10. MRI Evaluation of Post Core Decompression Changes in Avascular Necrosis of Hip

    PubMed Central

    Marupaka, Sravan Kumar; Alluri, Swathi; MD, Naseeruddin; Irfan, Kazi Amir; Jampala, Venkateshwarlu; Apsingi, Sunil; Eachempati, Krishna Kiran

    2015-01-01

    Introduction Avascular necrosis of hip typically presents in young patients. Core decompression in precollapse stage provides pain relief and preservation of femoral head. The results of core decompression vary considerably despite early diagnosis. The role of MRI in monitoring patients post surgically has not been clearly defined. Aim To study pre and post core decompression MRI changes in avascular necrosis of hip. Materials and Methods This is a contiguous observational cohort of 40 hips treated by core decompression for precollapse avascular necrosis of femoral head, who had a baseline MRI performed before surgery. Core decompression of the femoral head was performed within 4 weeks. Follow up radiograph and MRI scans were done at six months. Harris hip score preoperatively, 1 month and 6 months after the surgery was noted. Success in this study was defined as postoperative increase in Harris hip score (HHS) by 20 points and no additional femoral collapse. End point of clinical adverse outcome as defined by fall in Harris hip score was conversion or intention to convert to total hip replacement (THR). MRI parameters in the follow up scan were compared to the preoperative MRI. Effect of core decompression on bone marrow oedema and femoral head collapse was noted. Results were analysed using SPSS software version. Results Harris hip score improved from 57 to 80 in all patients initially. Six hips had a fall in Harris hip score to mean value of 34.1 during follow up (9 to 12 months) and underwent total hip replacement. MRI predictors of positive outcome are lesions with grade A extent, Grade A & B location. Bone marrow oedema with lesions less than 50% involvement, medial and central location. Conclusion Careful selection of patients by MR criteria for core decompression provides satisfactory outcome in precollapse stage of avascular necrosis of hip. PMID:26816966

  11. Revision Hip Arthroscopy Indications and Outcomes: A Systematic Review.

    PubMed

    Sardana, Vandit; Philippon, Marc J; de Sa, Darren; Bedi, Asheesh; Ye, Lily; Simunovic, Nicole; Ayeni, Olufemi R

    2015-10-01

    To identify the indications and outcomes in patients undergoing revision hip arthroscopy. The electronic databases Embase, Medline, HealthStar, and PubMed were searched from 1946 to July 19, 2014. Two blinded reviewers searched, screened, and evaluated the data quality of the studies using the Methodological Index for Non-Randomized Studies scale. Data were abstracted in duplicate. Agreement and descriptive statistics are presented. Six studies were included (3 prospective case series and 3 retrospective chart reviews), with a total of 448 hips examined. The most common indications for revision hip arthroscopy included residual femoroacetabular impingement (FAI), labral tears, and chondral lesions. The mean interval between revision arthroscopy and the index procedure was 25.6 months. Overall, the modified Harris Hip Score improved by a mean of 33.6% (19.3 points) from the baseline score at 1-year follow-up. In 14.6% of patients, further surgical procedures were required, including re-revision hip arthroscopy (8.0%), total hip replacement (5.6%), and hip resurfacing (1.0%). Female patients more commonly underwent revision hip arthroscopy (59.7%). The current evidence examined in this review supports revision hip arthroscopy as a successful intervention to improve functional outcomes (modified Harris Hip Score) and relieve pain in patients with residual symptoms after primary FAI surgery, although the outcomes are inferior when compared with a matched cohort of patients undergoing primary hip arthroscopy for FAI. The main indication for revision is a candidate who has symptoms due to residual cam- or pincer-type deformity that was either unaddressed or under-resected during the index operation. However, it is important to consider that the studies included in this review are of low-quality evidence. Surgeons should consider incorporating a minimum 2-year follow-up for individuals after index hip-preservation surgery because revisions tended to occur within this time frame. Level IV, systematic review of Level III and IV studies. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. Radiographic cup position following posterior and lateral approach to total hip arthroplasty. An explorative randomized controlled trial.

    PubMed

    Kruse, Christine; Rosenlund, Signe; Broeng, Leif; Overgaard, Søren

    2018-01-01

    The two most common surgical approaches to total hip arthroplasty are the posterior approach and lateral approach. The surgical approach may influence cup positioning and restoration of the offset, which may affect the biomechanical properties of the hip joint. The primary aim was to compare cup position between posterior approach and lateral approach. Secondary aims were to compare femoral offset, abductor moment arm and leg length discrepancy between the two approaches. Eighty patients with primary hip osteoarthritis were included in a randomized controlled trial and assigned to total hip arthroplasty using posterior approach or lateral approach. Postoperative radiographs from 38 patients in each group were included in this study for measurement of cup anteversion and inclination. Femoral offset, cup offset, total offset, abductor moment arm and leg length discrepancy were measured on preoperative and postoperative radiographs in 28 patients in each group. We found that mean anteversion was 5° larger in the posterior approach group (95% CI, -8.1 to -1.4; p = 0.006), while mean inclination was 5° less steep (95% CI, 2.7 to 7.2; p<0.001) compared with the lateral approach group. The posterior approach group had a larger mean femoral offset of 4.3mm (95% CI, -7.4 to -1.3, p = 0.006), mean total offset of 6.3mm (95% CI, -9.6 to -3; p<0.001) and mean abductor moment arm of 4.8mm (95% CI, -7.6 to -1.9; p = 0.001) compared with the lateral approach group. We found a larger cup anteversion but less steep cup inclination in the posterior approach group compared with the lateral approach group. Femoral offset and abductor moment arm were restored after total hip arthroplasty using lateral approach but significantly increased when using posterior approach.

  13. Total Hip Arthroplasty in an Inveterate Femoral Neck Fracture in a Patient with Congenital Insensitivity to Pain with Anhidrosis.

    PubMed

    Dagnino, Augusto; Ursino, Nicola; Ripamonti, Carlo A M; Fiorentini, Carlo E; Scelsi, Michele; D'Ambrosi, Riccardo; Portinaro, Nicola M

    2017-12-01

    Congenital insensitivity to pain with anhidrosis (CIPA) is an extremely rare disorder characterized by autonomic and sensory nerves malfunction with insensitivity to both deep and superficial painful stimuli, inability to sweat and produce tears, and mild to moderate mental retardation with self-mutilating behavior. Related consequences of inveterate musculoskeletal injuries represent a major issue for these patients, since pain cannot act as a protection mechanism. For the same reason, the patients are at risk during postoperative rehabilitation, which should be taken into account when selecting an orthopaedic implant. To our knowledge, only one case of total hip arthroplasty has been reported in the literature to date. A 21-year-old Caucasian male patient affected with CIPA arrived at our attention complaining about a functional limitation of the left hip. No history of trauma was reported. The X-rays showed an inveterate femoral neck fracture with a severe necrosis and resorption of the femoral head. We decided to perform a total hip arthroplasty with a cemented stem and a cemented dual mobility cup. The postoperative course and rehabilitation were satisfactory, with excellent clinical results, measured with the Harris Hip Score at 1 year.

  14. Medium-term outcome in patients treated with total hip arthroplasty using a modular femoral stem.

    PubMed

    Dagnino, Augusto; Grappiolo, Guido; Benazzo, Franco M; Learmonth, Ian D; Spotorno, Lorenzo; Portinaro, Nicola

    2012-01-01

    The clinical, radiographic and quality of life results of total hip arthroplasty using the MODULUS cementless modular femoral stem were reviewed. 48 patients who had a total hip arthroplasty using the MODULUS femoral stem were identified. Six had bilateral procedures, resulting in 60 hips with complete clinical and radiographic data. Mean age at implantation was 50 years (range 33 to 82). Mean follow-up was 59 months (range 50 months to 73). There were two early post-operative dislocations (within 2 days). One patient required further surgery to remove heterotopic bone. Mean Harris Hip Score increased from 37 points preoperatively (range, 7 to 66) to 89 points at final review (range, 65 to 100 points). Radiographic evaluation revealed that all implants were stable without evidence of osteolysis but three patients (5%) exhibited heterotopic ossification. Quality of life was evaluated with the SF36. The physical component increased from 29.2 points (range, 18.5 to 46.0) to 51.7 points (range 42.9 to 60.6) and the mental component from 375 points (range, 19.5 to 50.0) to 50 points (range 32,8 to 62.0).

  15. Total Hip Arthroplasty in an Inveterate Femoral Neck Fracture in a Patient with Congenital Insensitivity to Pain with Anhidrosis

    PubMed Central

    Dagnino, Augusto; Ursino, Nicola; Ripamonti, Carlo A. M.; Fiorentini, Carlo E.; Scelsi, Michele; D'Ambrosi, Riccardo; Portinaro, Nicola M.

    2017-01-01

    Congenital insensitivity to pain with anhidrosis (CIPA) is an extremely rare disorder characterized by autonomic and sensory nerves malfunction with insensitivity to both deep and superficial painful stimuli, inability to sweat and produce tears, and mild to moderate mental retardation with self-mutilating behavior. Related consequences of inveterate musculoskeletal injuries represent a major issue for these patients, since pain cannot act as a protection mechanism. For the same reason, the patients are at risk during postoperative rehabilitation, which should be taken into account when selecting an orthopaedic implant. To our knowledge, only one case of total hip arthroplasty has been reported in the literature to date. A 21-year-old Caucasian male patient affected with CIPA arrived at our attention complaining about a functional limitation of the left hip. No history of trauma was reported. The X-rays showed an inveterate femoral neck fracture with a severe necrosis and resorption of the femoral head. We decided to perform a total hip arthroplasty with a cemented stem and a cemented dual mobility cup. The postoperative course and rehabilitation were satisfactory, with excellent clinical results, measured with the Harris Hip Score at 1 year. PMID:29270564

  16. Preservation of the Acetabular Cup During Revision Total Hip Arthroplasty Using a Novel Mini-navigation Tool: A Case Report.

    PubMed

    Vincent, John; Alshaygy, Ibrahim; Muir, Jeffrey M; Kuzyk, Paul

    2018-01-01

    While intraoperative navigation systems have been shown to improve outcomes in primary total hip arthroplasty (THA), their use in the context of revision has been largely overlooked. This case report presents the first documented use of an imageless navigation tool in the context of revision THA, and an unexpected benefit to the surgical procedure as a result. An 84-year-old female patient presented following five episodes of dislocation of the left hip and with pain in the left buttock, groin, and posterior aspect of her hip. Relevant surgical history included primary hip arthroplasty in 1999 and the first revision in 2014. Preoperative analysis revealed a constrained liner that had become disengaged and migrated inferiorly, lodging at the distal aspect of the femoral neck. Acetabular protrusion was also noted. The pre-operative plan included the replacement of the fragmented liner and likely of the acetabular cup due to hardware failure. Intraoperative assessment, however, revealed that the cup was in good condition and would be difficult to remove due to substantial bony ingrowth. With the assistance of imageless navigation, the orientation of the acetabular cup was determined and a new constrained liner was cemented into the preexisting acetabular component at an altered orientation, correcting anteversion by 7°. In revision hip arthroplasty cases, image-based navigation is limited by the presence of existing implants and corresponding metal artefact. This case demonstrates the successful use of an imageless navigation tool for revision surgery. Use of navigation led to the unexpected intraoperative discovery that the acetabular cup was in an acceptable state, and allowed the surgical team to correct the position of the cup using a constrained liner, thus preserving the cup. This significantly benefitted patient outcome, due to the risks associated with the removal of a firmly fixated acetabular cup. While more extensive research is required, this case demonstrates that imageless navigation may be an indispensable tool for revision surgery.

  17. Early radiological and functional outcomes for a cementless press-fit design modular femoral stem revision system.

    PubMed

    Hancock, Douglas S; Sharplin, Paul K; Larsen, Peter D; Phillips, Fredrick Ts

    2018-05-01

    To assess early radiological and functional outcomes of revision hip surgery with a cementless press-fit design femoral stem. A retrospective review of 48 consecutive revision total hip replacements using the RECLAIM revision hip system, between October 2012 and August 2015. Radiographic assessment was undertaken with serial anteroposterior (AP) X-rays of the pelvis. Risk factors for subsidence were evaluated. Prospective clinical follow up was performed on 21 patients to assess functional outcomes. Mean stem subsidence was 1.1 mm (95% confidence interval[CI]: 0.63-1.57). Median follow up of 12 months. An inverse relationship was observed between level of subsidence and femoral stem diameter r = -0.45, p = 0.001. Subsidence at the time of follow-up assessment was correlated with initial subsidence (correlation coefficient rho 0.69, p = 0.001). The mean Merle d'Aubigne score at the latest follow up was 14.2 (range 8-17). The mean OHS was 34.1 (range 15-48). Early radiological and functional outcomes for the RECLAIM revision system showed very low levels of subsidence and good functional outcomes. There was an association with smaller diameter femoral stems and greater levels of subsidence.

  18. Validation of gait analysis with dynamic radiostereometric analysis (RSA) in patients operated with total hip arthroplasty.

    PubMed

    Zügner, Roland; Tranberg, Roy; Lisovskaja, Vera; Shareghi, Bita; Kärrholm, Johan

    2017-07-01

    We simultaneously examined 14 patients with OTS and dynamic radiostereometric analysis (RSA) to evaluate the accuracy of both skin- and a cluster-marker models. The mean differences between the OTS and RSA system in hip flexion, abduction, and rotation varied up to 9.5° for the skin-marker and up to 11.3° for the cluster-marker models, respectively. Both models tended to underestimate the amount of flexion and abduction, but a significant systematic difference between the marker and RSA evaluations could only be established for recordings of hip abduction using cluster markers (p = 0.04). The intra-class correlation coefficient (ICC) was 0.7 or higher during flexion for both models and during abduction using skin markers, but decreased to 0.5-0.6 when abduction motion was studied with cluster markers. During active hip rotation, the two marker models tended to deviate from the RSA recordings in different ways with poor correlations at the end of the motion (ICC ≤0.4). During active hip motions soft tissue displacements occasionally induced considerable differences when compared to skeletal motions. The best correlation between RSA recordings and the skin- and cluster-marker model was found for studies of hip flexion and abduction with the skin-marker model. Studies of hip abduction with use of cluster markers were associated with a constant underestimation of the motion. Recordings of skeletal motions with use of skin or cluster markers during hip rotation were associated with high mean errors amounting up to about 10° at certain positions. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1515-1522, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  19. Ten different hip resurfacing systems: biomechanical analysis of design and material properties.

    PubMed

    Heisel, Christian; Kleinhans, Jennifer A; Menge, Michael; Kretzer, Jan Philippe

    2009-08-01

    This study gives an overview of the main macro- and microstructural differences of ten commercially available total hip resurfacing implants. The heads and cups of resurfacing hip implants from ten different manufacturers were analysed. The components were measured in a coordinate measuring machine. The microstructure of the heads and cups was inspected by scanning electron microscopy. The mean radial clearance was 84.86 microm (range: 49.47-120.93 microm). The implants were classified into three groups (low, medium and high clearance). All implants showed a deviation of roundness of less than 10 microm. It was shown that all implants differ from each other and a final conclusion about the ideal design and material combination cannot be given based on biomechanical data. Widespread use of specific designs can only be recommended if clinical long-term follow-up studies are performed and analysed for each design.

  20. Metal-on-Metal Total Hip Arthroplasty: Quality of Online Patient Information.

    PubMed

    Crozier-Shaw, Geoff; Queally, Joseph M; Quinlan, John F

    2017-03-01

    Metal-on-metal total hip arthroplasty (THA) has generated much attention in the media because of early failure of certain implant systems. This study assessed the quality, accuracy, and readability of online information on metal-on-metal THA. The search terms "metal-on-metal hip replacement" and "metal hip replacement" were entered into the 3 most popular search engines. Information quality was assessed with the DISCERN score and a specific metal-on-metal THA content score. Accuracy of information was assessed with a customized score. Readability of the websites was assessed with the Flesch-Kincaid grade level score. A total of 61 unique websites were assessed. For 56% of websites, the target audience was patients. Media or medicolegal sources accounted for 44% of websites. As assessed by DISCERN (range, 16-80) and metal-on-metal THA (range, 0-25) scores, quality of the websites was moderate at best (47.1 and 9.6, respectively). Accuracy (range, 0-8) of the information presented also was moderate, with a mean score of 6.6. Media and medicolegal websites had the lowest scores for both quality and accuracy, despite making up the greatest proportion of sites assessed. Only 1 website (2%) had a Flesch-Kincaid grade level at or less than the recommended level of 8th grade. This study found that online information on metal-on-metal THA was of poor quality, often was inaccurate, and was presented at an inappropriately high reading level, particularly for media and medicolegal websites. Health care providers should counsel patients on the quality of information available and recommend appropriate online resources. [Orthopedics. 2017; 40(2):e262-e268.]. Copyright 2016, SLACK Incorporated.

  1. Nationwide multicenter follow-up cohort study of hip arthroplasties performed for osteonecrosis of the femoral head.

    PubMed

    Kobayashi, Seneki; Kubo, Toshikazu; Iwamoto, Yukihide; Fukushima, Wakaba; Sugano, Nobuhiko

    2018-05-12

    To identify modifiable factors related to post-operative dislocation and reoperation in patients with osteonecrosis of the femoral head (ONFH) in a large cohort. We studied 4995 hip arthroplasties: total hip arthroplasty (THA) was performed in 79% of patients; bipolar hemiarthroplasty (BP), 17%; total resurfacing arthroplasty (tRS), 3%; and hemi-resurfacing arthroplasty (hRS), 1%. A new type of BP (accounting for 49% of BPs) comprised a femoral component with a polished or smooth, small-diameter (approximately 10 mm) neck with a round or oval axial cut surface and no sharp corners. The infection rate was relatively low (0.56%) even though 58% of cases of ONFH were associated with systemic steroid use, a known risk factor for infection. Post-operative dislocation occurred in 4.3% of cases, with re-operation needed in 3.9%. The dislocation rate was related to surgery type: 5.2% in THA, 0.9% in BP, and 0% in tRS and hRS. Among total arthroplasties with six month or longer follow-up (3670 THAs and 159 tRSs), the risk factors for post-operative dislocation were younger (≤ 40 years) or older (≥ 62 years) age, higher body weight, posterolateral approach, and smaller prosthetic head diameter. Regarding the need for re-operation, higher body weight and surgery type were identified as risk factors. The relatively high dislocation rate of 5.2% in THA is a cause for concern. The identified risk factors for dislocation should be considered when selecting THA for treatment. Prosthesis survivorship in hRSs was inferior to that in BPs or THAs. Body weight also affected the survivorship of hip arthroplasties.

  2. Methodologies for semiquantitative evaluation of hip osteoarthritis by magnetic resonance imaging: approaches based on the whole organ and focused on active lesions.

    PubMed

    Jaremko, Jacob L; Lambert, Robert G W; Zubler, Veronika; Weber, Ulrich; Loeuille, Damien; Roemer, Frank W; Cibere, Jolanda; Pianta, Marcus; Gracey, David; Conaghan, Philip; Ostergaard, Mikkel; Maksymowych, Walter P

    2014-02-01

    As a wider variety of therapeutic options for osteoarthritis (OA) becomes available, there is an increasing need to objectively evaluate disease severity on magnetic resonance imaging (MRI). This is more technically challenging at the hip than at the knee, and as a result, few systematic scoring systems exist. The OMERACT (Outcome Measures in Rheumatology) filter of truth, discrimination, and feasibility can be used to validate image-based scoring systems. Our objective was (1) to review the imaging features relevant to the assessment of severity and progression of hip OA; and (2) to review currently used methods to grade these features in existing hip OA scoring systems. A systematic literature review was conducted. MEDLINE keyword search was performed for features of arthropathy (such as hip + bone marrow edema or lesion, synovitis, cyst, effusion, cartilage, etc.) and scoring system (hip + OA + MRI + score or grade), with a secondary manual search for additional references in the retrieved publications. Findings relevant to the severity of hip OA include imaging markers associated with inflammation (bone marrow lesion, synovitis, effusion), structural damage (cartilage loss, osteophytes, subchondral cysts, labral tears), and predisposing geometric factors (hip dysplasia, femoral-acetabular impingement). Two approaches to the semiquantitative assessment of hip OA are represented by Hip OA MRI Scoring System (HOAMS), a comprehensive whole organ assessment of nearly all findings, and the Hip Inflammation MRI Scoring System (HIMRISS), which selectively scores only active lesions (bone marrow lesion, synovitis/effusion). Validation is presently confined to limited assessment of reliability. Two methods for semiquantitative assessment of hip OA on MRI have been described and validation according to the OMERACT Filter is limited to evaluation of reliability.

  3. Lower limb joint work and joint work contribution during downhill and uphill walking at different inclinations.

    PubMed

    Alexander, Nathalie; Strutzenberger, Gerda; Ameshofer, Lisa Maria; Schwameder, Hermann

    2017-08-16

    Work performance and individual joint contribution to total work are important information for creating training protocols, but were not assessed so far for sloped walking. Therefore, the purpose of this study was to analyze lower limb joint work and joint contribution of the hip, knee and ankle to total lower limb work during sloped walking in a healthy population. Eighteen male participants (27.0±4.7yrs, 1.80±0.05m, 74.5±8.2kg) walked on an instrumented ramp at inclination angles of 0°, ±6°, ±12° and ±18° at 1.1m/s. Kinematic and kinetic data were captured using a motion-capture system (Vicon) and two force plates (AMTI). Joint power curves, joint work (positive, negative, absolute) and each joint's contribution to total lower limb work were analyzed throughout the stance phase using an ANOVA with repeated measures. With increasing inclination positive joint work increased for the ankle and hip joint and in total during uphill walking. Negative joint work increased for each joint and in total work during downhill walking. Absolute work was increased during both uphill (all joints) and downhill (ankle & knee) walking. Knee joint contribution to total negative and absolute work increased during downhill walking while hip and ankle contributions decreased. This study identified, that, when switching from level to a 6° and from 6° to a 12° inclination the gain of individual joint work is more pronounced compared to switching from 12° to an 18° inclination. The results might be used for training recommendations and specific training intervention with respect to sloped walking. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Preoperative anaemia is associated with increased allogeneic pack red cell transfusion in revision hip and knee joint arthroplasty: a retrospective analysis of 5387 patients over a 10-year period at a single high volume centre.

    PubMed

    Kasivisvanathan, R; Ramesh, V; Rao Baikady, R; Nadaraja, S

    2016-08-01

    To estimate the prevalence of preoperative World Health Organization (WHO) defined anaemia in patients presenting for revision hip and knee arthroplasty and its association with transfusion of allogeneic packed red blood cells (PRBC). Studies have mainly investigated the prevalence of preoperative anaemia in primary and not revision hip and knee joint arthroplasty. An analysis of a prospectively collected patient data for 5387 patients having revision hip or knee arthroplasty over a 10-year period at a single high volume centre was conducted. Logistic regression was used to assess whether the presence of WHO defined preoperative anaemia as well as other risk factors were associated with inpatient allogeneic PRBC transfusion. There were 5387 patients assessed of which 3021 (56·01%) patients had revision total hip replacements and 2366 (43·09%) had revision total knee arthroplasty. Of these patients 1956 (36·03%) had preoperative WHO defined anaemia. A total of 2034 (37·08%) patients received at least one unit of allogeneic PRBC during their primary hospital admission. In the final model preoperative WHO defined anaemia was independently associated with allogeneic PRBC transfusion in hip and knee revision surgery OR 4·042 (4·012-4·072 95% CI) CONCLUSIONS: Preoperative anaemia is common in patients presenting for revision hip and knee arthroplasty and independently associated with transfusion of allogeneic PRBC. © 2016 British Blood Transfusion Society.

  5. [Survey on the use and behaviour of metal-metal hip replacements in Spain].

    PubMed

    Calcerrada, N; Fernández-Vega, A; Valls-León, C; Garcia-Cimbrelo, E

    2016-01-01

    Following medical device alerts published in different countries of problems with metal-on-metal total hip replacements, the Spanish Agency of Medicines and Medical Devices (AEMPS) in collaboration with the Spanish Hip Society Surgery designed a national survey to gather information on the use and behaviour of these hip implants. The survey consisted of a questionnaire sent by e-mail to 283 clinical centre recipients of metal-on-metal hips to be filled in by surgeons with expertise in the field. A total of 257 questionnaires were completed. The response rate of the clinical centres was 36.7%. A total of 97.7% of the responses reported that clinical and radiological follow-ups are carried out, and 79.6% undertook metal ion analyses (chromium and cobalt). A large majority (83.6%) of the responders who had who used surface implants, and 70% of those with large-head implants reported peri-operative complications. The most common complication was pain (25% with surface implants and 30.8% with large-head implants). Currently 80.8% of those responding were considering abandoning implanting of these hip replacements. Despite the many limitations to this study, the survey has allowed us to obtain in a quick first view of the implant scenario of Metal on Metal hip implants in Spain, and to determine the type of patient implanted, the time of implantation, and the experience/expertise of the surgeons, and the type of follow-up carried out. Copyright © 2015 SECOT. Published by Elsevier Espana. All rights reserved.

  6. Metal-on-Metal Hip Retrieval Analysis: A Case Report

    PubMed Central

    Pace, Thomas B.; Rusaw, Kara A.; Minette, Lawrence J.; Shirley, Brayton R.; Snider, Rebecca G.; DesJardins, John D.

    2013-01-01

    This is a case report involving a single case with severe bone and soft tissue destruction in a young male patient with a 10-year-metal on-metal total hip arthroplasty. Following complete aseptic erosion of the affected hip greater trochanter and abductor muscles, the hip was revised for recurrent instability. Histological examination of the patient's periprosthetic tissues, serological studies, and review of recent medical reports of similar cases were used to support an explanation of the destructive process and better contribute to our understanding of human reaction to metal debris in some patients following metal-on-metal hip arthroplasty. PMID:23840999

  7. Conversion of hip fusion to total hip arthroplasty: clinical, radiological outcomes and complications in 40 hips.

    PubMed

    Celiktas, Mustafa; Kose, Ozkan; Turan, Adil; Guler, Ferhat; Ors, Cagri; Togrul, Emre

    2017-01-01

    The purpose of this retrospective study is to report the clinical and radiological outcome of total hip arthroplasty in patients with previous hip arthrodesis. We retrospectively reviewed 28 (40 hips) prospectively followed patients in whom ankylosed hips were converted to total hip arthroplasty (THA) between 2010 and 2014 in our institution. The average age at the time of the conversion operation was 40.8 ± 9.8 years (range 24-62). The ankylosis had lasted 20.4 ± 13.0 years (range 3-56) before conversion surgery. The etiology of the ankylosis was septic arthritis in 10 (25%), post-traumatic hip osteoarthritis in 8 (20%), developmental hip dysplasia in 6 (15%), rheumatoid arthritis in 6 (15%), primary osteoarthritis in 5 (12.5%) and ankylosing spondylitis in 5 (12.5%) hips. The indications for arthroplasty were intractable low back pain in 14 (50%), hip pain in 24 (85.7%), and ipsilateral knee pain in 19 (67.8%) patients. Harris Hip Score (HHS) was used to rate the clinical results before and after the surgery. Radiographic evaluations included component malposition and loosening. All complications during the study period were recorded. The mean follow-up period was 39.9 ± 10.6 months (range 24-60). The mean preoperative HHS was 33.3 ± 8.6 (range 18-50) and the mean HHS at the final follow-up was 74.9 ± 8.6 (range 52-97). There was a statistically significant increase in HHS (p = 0.0001). HHS was excellent in 1, good in 6, fair in 14 and poor in 7 patients. Increase in HHS was lower than 20 points in one patient (18 points), and one patient required two-staged exchange procedure due to deep infection. Thus, according to our success criteria (increase in HHS more than 20 points, radiographically stable implant, and no further surgical reconstruction), 92.8% (26/28) of patients had benefit from the surgery. Trendelenburg sign was positive in 12 hips. There was limb length inequality in 11 patients (mean 0.5 cm, range 1-3 cm). No patients had heterotopic ossification, sciatic nerve palsy or dislocation. There were five intra-operative fractures of the greater trochanter that were treated with cable wiring. One patient had trochanteric avulsion injury and was treated with trochanteric grip and cables. One patient (2.5%) had deep infection one year after the conversion THA and was treated with two-staged exchange procedure. Conversion hip arthroplasty is an effective treatment method which provides functional recovery and patient satisfaction. However, a proper surgical technique and planning is necessary to minimize the complications.

  8. Female Sex Is a Risk Factor for Failure of Hip Arthroscopy Performed for Acetabular Retroversion

    PubMed Central

    Poehling-Monaghan, Kirsten L.; Krych, Aaron J.; Levy, Bruce A.; Trousdale, Robert T.; Sierra, Rafael J.

    2017-01-01

    Background: The success of hip surgery in treating acetabular retroversion depends on the severity of the structural deformity and on selecting the correct patient for open or arthroscopic procedures. Purpose: To compare a group of patients with retroverted hips treated successfully with hip arthroscopy with a group of patients with retroverted hips that failed arthroscopic surgery, with special emphasis on (1) patient characteristics, (2) perioperative radiographic parameters, (3) intraoperative findings and concomitant procedures, and (4) patient sex. Study Design: Case-control study; Level of evidence, 3. Methods: We retrospectively reviewed the charts of 47 adult patients (47 hips) with acetabular retroversion who had undergone hip arthroscopy. Retroversion was based on the presence of an ischial spine sign in addition to either a crossover or posterior wall sign on a well-positioned anteroposterior pelvic radiograph. A total of 24 hips (50%) (16 females, 8 males; mean patient age, 31 years) had failed arthroscopy, defined as modified Harris Hip Score (mHHS) <80 or need for subsequent procedure. Twenty-three hips (8 females, 15 males; mean patient age, 29 years) were considered successful, defined as having no subsequent procedures and an mHHS >80 at the time of most recent follow-up. Perioperative variables, radiographic characteristics, and intraoperative findings were compared between the groups, in addition to a subgroup analysis based on sex. Results: The mean follow-up for successful hips was 30 months (SD, 11 months), with a mean mHHS of 95. In the failure group, 6 patients required subsequent procedures (4 anteverting periacetabular osteotomies and 2 total hip arthroplasties). The mean overall time to failure was 21 months, and the mean time to a second procedure was 24 months (total hip arthroplasty, 29.5 months; periacetabular osteotomy, 21.2 months); 18 hips failed on the basis of a low mHHS (mean, 65; range, 27-79) at last follow-up. Factors significantly different between the success and failure groups included patient sex, with males being more likely than females to have a successful outcome (P < .02), as well as undergoing femoral osteoplasty (P < .02). Intraoperative variables that were associated with worse outcome included isolated labral debridement (P < .002). In a subgroup analysis, males were more likely than their female counterparts to have a successful outcome with both isolated cam and combined cam-pincer resection (P < .05). Level of crossover correction on postoperative radiographs had no correlation with outcome. Conclusion: Acetabular retroversion remains a challenging pathoanatomy to treat arthroscopically. If hip arthroscopy is to be considered in select cases, we recommend labral preservation when possible. Male patients with correction of cam deformities did well, while females with significant retroversion appeared to be at greater risk for failure of arthroscopic treatment. PMID:29164164

  9. The influence of optimism on functionality after total hip replacement surgery.

    PubMed

    Balck, Friedrich; Lippmann, Maike; Jeszenszky, Csilla; Günther, Klaus-Peter; Kirschner, Stephan

    2016-08-01

    Among other factors, optimism has been shown to significantly influence the course of some diseases (cancer, HIV, coronary heart disease). This study investigated whether optimism of a patient before a total hip replacement can predict the functionality of the lower limbs 3 and 6 months after surgery. A total of 325 patients took part in the study (age: 58.7 years; w: 55%). The functionality was measured with the Western Ontario and McMaster Universities arthrosis index, and optimism with the Life Orientation Test. To analyse the influences of age, gender and optimism, general linear models were calculated. In optimistic patients, functionality improved significantly over time. The study showed a clear influence of dispositional optimism on the recovery after total hip replacement in the first 3 months after surgery. © The Author(s) 2015.

  10. Hip resurfacing: a large, US single-surgeon series.

    PubMed

    Brooks, P J

    2016-01-01

    Hip resurfacing has been proposed as an alternative to traditional total hip arthroplasty in young, active patients. Much has been learned following the introduction of metal-on-metal resurfacing devices in the 1990s. The triad of a well-designed device, implanted accurately, in the correct patient has never been more critical than with these implants. Following Food and Drug Administration approval in 2006, we studied the safety and effectiveness of one hip resurfacing device (Birmingham Hip Resurfacing) at our hospital in a large, single-surgeon series. We report our early to mid-term results in 1333 cases followed for a mean of 4.3 years (2 to 5.7) using a prospective, observational registry. The mean patient age was 53.1 years (12 to 84); 70% were male and 91% had osteoarthritis. Complications were few, including no dislocations, no femoral component loosening, two femoral neck fractures (0.15%), one socket loosening (0.08%), three deep infections (0.23%), and three cases of metallosis (0.23%). There were no destructive pseudotumours. Overall survivorship at up to 5.7 years was 99.2%. Aseptic survivorship in males under the age of 50 was 100%. We believe this is the largest United States series of a single surgeon using a single resurfacing system. ©2016 The British Editorial Society of Bone & Joint Surgery.

  11. Avascular necrosis as a complication of the treatment of dislocation of the hip in children with cerebral palsy.

    PubMed

    Koch, A; Jozwiak, M; Idzior, M; Molinska-Glura, M; Szulc, A

    2015-02-01

    We investigated the incidence and risk factors for the development of avascular necrosis (AVN) of the femoral head in the course of treatment of children with cerebral palsy (CP) and dislocation of the hip. All underwent open reduction, proximal femoral and Dega pelvic osteotomy. The inclusion criteria were: a predominantly spastic form of CP, dislocation of the hip (migration percentage, MP > 80%), Gross Motor Function Classification System, (GMFCS) grade IV to V, a primary surgical procedure and follow-up of > one year. There were 81 consecutive children (40 girls and 41 boys) in the study. Their mean age was nine years (3.5 to 13.8) and mean follow-up was 5.5 years (1.6 to 15.1). Radiological evaluation included measurement of the MP, the acetabular index (AI), the epiphyseal shaft angle (ESA) and the pelvic femoral angle (PFA). The presence and grade of AVN were assessed radiologically according to the Kruczynski classification. Signs of AVN (grades I to V) were seen in 79 hips (68.7%). A total of 23 hips (18%) were classified between grades III and V. Although open reduction of the hip combined with femoral and Dega osteotomy is an effective form of treatment for children with CP and dislocation of the hip, there were signs of avascular necrosis in about two-thirds of the children. There was a strong correlation between post-operative pain and the severity of the grade of AVN. ©2015 The British Editorial Society of Bone & Joint Surgery.

  12. [Modern tribology in total hip arthroplasty: pros and cons].

    PubMed

    Gómez-García, F

    2014-01-01

    The wear products and adverse reactions that occur on bearing surfaces represent one of the greatest challenges in prosthetic replacements, as the latter experience increasing demands due to the large number of young and older adult patients that have a long life expectancy and remarkable activity. The purpose of this review is to analyze the pros and cons of the new advances in the bearing components of the articular surfaces of current total hip arthroplasties. We also discuss the strategies used historically, their problems, results and the surgeon's role in prescribing the tribologic couple that best fits each patient's needs. We conclude with practical recommendations for the prescription and management of the latest articular couples for total hip arthroplasty.

  13. Patient Satisfaction Reporting After Total Hip Arthroplasty: A Systematic Review.

    PubMed

    Kahlenberg, Cynthia A; Nwachukwu, Benedict U; Schairer, William W; Steinhaus, Michael E; Cross, Michael B

    2017-05-01

    This review evaluated the quality of patient satisfaction reporting after total hip arthroplasty. The initial search of the MEDLINE database yielded 755 studies. Twenty-four met the inclusion criteria. Most studies provided level III or IV evidence (n=15, 62.5%). The most common method used to assess satisfaction was the 10-point visual analog scale (7 studies, 29.2%), followed by an ordinal satisfaction scale (6 studies, 25.0%). The quality of evidence was poor, and the methods used to assess satisfaction were not standardized. Further research is needed to define the factors that affect patient satisfaction after total hip arthroplasty and how satisfaction is best measured. [Orthopedics. 2017; 40(3):e400-e404.]. Copyright 2017, SLACK Incorporated.

  14. Dissociation of modular total hip arthroplasty at the neck-stem interface without dislocation.

    PubMed

    Kouzelis, A; Georgiou, C S; Megas, P

    2012-12-01

    Modular femoral and acetabular components are now widely used, but only a few complications related to the modularity itself have been reported. We describe a case of dissociation of the modular total hip arthroplasty (THA) at the femoral neck-stem interface during walking. The possible causes of this dissociation are discussed. Successful treatment was provided with surgical revision and replacement of the modular neck components. Surgeons who use modular components in hip arthroplasties should be aware of possible early complications in which the modularity of the prostheses is the major factor of failure.

  15. Determining Health-Related Quality-of-Life Outcomes Using the SF-6D Following Total Hip Arthroplasty.

    PubMed

    Elmallah, Randa K; Chughtai, Morad; Adib, Farshad; Bozic, Kevin J; Kurtz, Steven M; Mont, Michael A

    2017-03-15

    Following total hip arthroplasty, patients' perception of their postoperative improvement and health plays a large role in satisfaction with and success of the surgical procedure. The Short Form-6D (SF-6D) is a health-related quality-of-life measure that assigns numerical value to the perception of patients' own health. The purpose was to determine SF-6D values of patients after total hip arthroplasty, to determine whether score changes were clinically relevant, and to compare these with postoperative functional improvements. We evaluated 188 patients who underwent primary total hip arthroplasty at 7 institutions and who had a mean age of 69 years (range, 47 to 88 years) and a mean body mass index of 28.8 kg/m (range, 19.8 to 38.9 kg/m). The SF-6D values were obtained from patients' SF-36 scores, and clinical relevance of value changes was determined using effect size. Using previous research, effect sizes were considered small between 0.2 and 0.5, moderate between 0.6 to 0.8, and large at >0.8. Clinical correlation was assessed using the Lower-Extremity Activity Scale and Harris hip scores. Patients were assessed preoperatively and postoperatively at 6 months and 1, 2, 3, and 5 years. The SF-6D scores improved from preoperatively and achieved significance (p < 0.05) at all points. The effect size demonstrated good clinical relevance up to the latest follow-up: 1.27 at 6 months, 1.30 at 1 year, 1.07 at 2 years, 1.08 at 3 years, and 1.05 at 5 years. The Lower-Extremity Activity Scale improved at all follow-up points from preoperatively to 1.8 at 6 months, 2.0 at 1 year, 1.8 at 2 years, 1.5 at 3 years, and 1.6 points at 5 years. The Harris hip score improved to 38 points at 6 months, 40 points at 1 year, 38 points at 2 years, 39 points at 3 years, and 41 points at 5 years postoperatively. The improvements in the Lower-Extremity Activity Scale and the Harris hip score significantly positively correlated (p < 0.01) with the SF-6D scores at all time points. SF-6D scores after total hip arthroplasty correlate with functional outcomes and have clinical relevance, as demonstrated by their effect size. Incorporating this straightforward and easy-to-use measurement tool when evaluating patients following total hip arthroplasty will facilitate future cost-utility analyses. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  16. [Poldi-Čech cemented femoral stem in total hip arthroplasty after 25 years].

    PubMed

    Rozkydal, Z; Janíček, P

    2010-08-01

    The aim of the study was to evaluate the results of Poldi-Čech femoral stem implantation in primary total hip arthroplasty after 25 years. A group of 65 patients (90 hips) with Poldi-Čech total hip arthroplasty carried out between 1974 and 1984 was evaluated at the end of 2009. The mean follow-up of all patients was 28 years (25 to 35). There were seven men and 58 women. The mean age at the time of implantation was 43 years (26 to 60) and at the latest follow-up it was 72 years. In all patients the cemented UHMW PE acetabular component (RCH 1000) was used together with AKV Ultra 2 Poldi steel femoral stems (1st, 2nd and 3rd generations). The stem was a monoblock with a 32-mm head. The evaluation of the results was based on the Harris hip score and X ray with an A-P view of the pelvis and the affected hip. Statistical analysis was made using the life-table method. At the latest follow up the mean Harris score was 69.7 points (40 to 88). There were 69 hips with an original Poldi-Čech femoral component still in situ, 64 of them were stable and five with radiological evidence of aseptic loosening. Five patients had undergone Girdlestone resection arthroplasty for septic loosening. Thirteen patients (16 hips) had femoral stem revision. The cumulative proportion of clinical survivorship of the Poldi-Čech femoral stem, with revision for any reason as the endpoint, .was 0.93 at 6 years, 0.84 at 12 years, and 0.77 at 18, 24 and 30 years after the index surgery. Radiographic findings revealed 64 hips with stable stems, five hips with ;aseptic loosening (probable, 0 possible, 2, definite, 3). Six- teen hips were after revision surgery for aseptic loosening of the stem and five hips were after Girdlestone resection arthroplasty for septic failure. The cumulative proportion of radiological survivorship of the Poldi-Čech femoral stem with any reason as the endpoint was 0.92 at 6 years, 0.78 at 12 years, 0.72 at 18 years, 0.69 at 24 years and 0.69 at 30 years. The Poldi-Čech stem with its anatomical shape and a highly polished surface meets the principles of successful composite beam stems. Its disadvantage is a valgus neck- shaft angle of 140° giving lower femoral offset and the risk of development of valgus deformity of the ipsilateral knee. In most cases osteolysis, radiolucent lines and bone rarefaction of the femur resulted from polyethylene wear of the acetabular component. This study demonstrates a long-term survivorship of the Poldi-Čech femoral component in patients undergoing total hip arthroplasty 25 to 35 years ago.

  17. Impact of the economic downturn on total joint replacement demand in the United States: updated projections to 2021.

    PubMed

    Kurtz, Steven M; Ong, Kevin L; Lau, Edmund; Bozic, Kevin J

    2014-04-16

    Few studies have explored the role of the National Health Expenditure and macroeconomics on the utilization of total joint replacement. The economic downturn has raised questions about the sustainability of growth for total joint replacement in the future. Previous projections of total joint replacement demand in the United States were based on data up to 2003 using a statistical methodology that neglected macroeconomic factors, such as the National Health Expenditure. Data from the Nationwide Inpatient Sample (1993 to 2010) were used with United States Census and National Health Expenditure data to quantify historical trends in total joint replacement rates, including the two economic downturns in the 2000s. Primary and revision hip and knee arthroplasty were identified using codes from the International Classification of Diseases, Ninth Revision, Clinical Modification. Projections in total joint replacement were estimated using a regression model incorporating the growth in population and rate of arthroplasties from 1993 to 2010 as a function of age, sex, race, and census region using the National Health Expenditure as the independent variable. The regression model was used in conjunction with government projections of National Health Expenditure from 2011 to 2021 to estimate future arthroplasty rates in subpopulations of the United States and to derive national estimates. The growth trend for the incidence of joint arthroplasty, for the overall United States population as well as for the United States workforce, was insensitive to economic downturns. From 2009 to 2010, the total number of procedures increased by 6.0% for primary total hip arthroplasty, 6.1% for primary total knee arthroplasty, 10.8% for revision total hip arthroplasty, and 13.5% for revision total knee arthroplasty. The National Health Expenditure model projections for primary hip replacement in 2020 were higher than a previously projected model, whereas the current model estimates for total knee arthroplasty were lower. Economic downturns in the 2000s did not substantially influence the national growth trends for hip and knee arthroplasty in the United States. These latest updated projections provide a basis for surgeons, hospitals, payers, and policy makers to plan for the future demand for total joint replacement surgery.

  18. Does the addition of hip strengthening exercises improve outcomes following total knee arthroplasty? A study protocol for a randomized trial.

    PubMed

    Schache, Margaret B; McClelland, Jodie A; Webster, Kate E

    2016-06-13

    Total knee arthroplasty (TKA) is effective in reducing pain and improving function for end-stage knee osteoarthritis. However, muscle weakness and functional limitations persist despite assistance from post-operative rehabilitation programs that traditionally focus on quadriceps strengthening and range of movement exercises. Hip abductor muscle weakness is evident in knee osteoarthritis and hip muscle strengthening reduces knee pain in this group. Following TKA, people with weak hip abductor strength perform more poorly on measures of physical function. However, very little is known of the effectiveness of including hip abductor strengthening exercises in post-operative rehabilitation. The aim of this trial is to compare the effects of targeted hip abductor strengthening to those of traditional care in a TKA rehabilitation program on muscle strength, patient reported outcomes and functional performance measures. This protocol describes a single-blinded randomized controlled trial, where 104 participants referred for inpatient rehabilitation following TKA will be recruited. Participants will be randomized using computer-generated numbers to one of two groups: usual care or usual care with additional hip strengthening exercises. Participants will attend physiotherapy daily during their inpatient length of stay, and will then attend between six and eight physiotherapy sessions as an outpatient. Primary outcomes are isometric hip abductor strength and the Knee Injury and Osteoarthritis Outcome Score (KOOS). Secondary outcomes are stair climb test, 6 min walk test, timed up and go, 40 m fast-paced walk test, 30 second chair stand test, isometric quadriceps strength, Lower Extremity Functional Scale (LEFS) and SF-12. Outcome measures will be recorded at baseline (admission to inpatient rehabilitation), and then 3 weeks, 6 weeks and 6 months post admission to rehabilitation. The findings of this study will determine whether the addition of targeted hip strengthening to usual care rehabilitation improves physical performance and patient reported outcomes following TKA when compared to usual care rehabilitation. This will then determine whether targeted hip strengthening exercises should be included in traditional rehabilitation programs to improve the outcomes following total knee arthroplasty. The trial protocol was registered with the Australian Clinical Trial Registry ( ACTRN12615000863538 ) on 18 August 2015.

  19. Surgical dislocation of the hip and the management of femoroacetabular impingement: results of the Christchurch experience.

    PubMed

    Kempthorne, Joshua T; Armour, Paul C; Rietveld, John A; Hooper, Gary J

    2011-06-01

    Surgical dislocation of the hip has been developed to deal with the problems causing femoroacetabular impingement (FAI). This is a relatively recent procedure that was historically reserved for larger areas specializing in hip surgery. We hypothesized that surgical dislocation can be used for symptomatic FAI in a typical Australasian tertiary orthopaedic centre with acceptable results. This prospective study reviews the results of 53 surgical dislocations in this setting, looking particularly at functional outcomes and early complications. There were significant improvements in the Western Ontario and McMaster University Osteoarthritis Index score at 1, 2, 3 and 4 years post-operatively. Western Ontario and McMaster University Osteoarthritis Index scores increased by 23, 28, 34 and 35 points, respectively (P 0.0039). There was no significant improvement in hip range of motion. There were two (4%) early failures with conversion to total hip arthroplasty, and no cases of post-operative avascular necrosis of the femoral head. We believe that as the diagnosis of FAI and conservative nonarthroplasty surgery of the hip gains wider acceptance, it will become a procedure that should be offered to all appropriate patients in an attempt to delay or limit total hip arthroplasty in this young age group.

  20. Lessons learned from study of congenital hip disease in adults.

    PubMed

    Hartofilakidis, George; Lampropoulou-Adamidou, Kalliopi

    2016-12-18

    Orthopaedic surgeons specialising in adult hip reconstruction surgery often face the problem of osteoarthritis secondary to congenital hip disease (CHD). To achieve better communication among physicians, better treatment planning and evaluation of the results of various treatment options, an agreed terminology is needed to describe the entire pathology. Furthermore, a generally accepted classification of the deformities is necessary. Herein, the authors propose the use of the term "congenital hip disease" and its classification as dysplasia, low dislocation and high dislocation. Knowledge of the CHD natural history facilitates comprehension of the potential development and progression of the disease, which differs among the aforementioned types. This can lead to better understanding of the anatomical abnormalities found in the different CHD types and thus facilitate preoperative planning and choice of the most appropriate management for adult patients. The basic principles for improved results of total hip replacement in patients with CHD, especially those with low and high dislocation, are: Wide exposure, restoration of the normal centre of rotation and the use of special techniques and implants for the reconstruction of the acetabulum and femur. Application of these principles during total hip replacement in young female patients born with severe deformities of the hip joint has led to radical improvement of their quality of life.

  1. Pre-operative digital templating in cemented hip hemiarthroplasty for neck of femur fractures.

    PubMed

    Kwok, Iris H Y; Pallett, Scott J C; Massa, Edward; Cundall-Curry, Duncan; Loeffler, Mark D

    2016-03-01

    Pre-operative digital templating allows the surgeon to foresee any anatomical anomalies which may lead to intra-operative problems, and anticipate appropriate instruments and implants required during surgery. Although its role is well-established in successful elective total hip arthroplasty, little work has been done on its use in hip hemiarthroplasty in neck of femur fractures. We describe our initial experience of digital templating in 40 consecutive patients who have undergone cemented hip hemiarthroplasty, assessing templating accuracy between templated implant sizes to actual implant sizes. 81% of implanted heads were templated to within two head sizes, and 89% of implanted stems were templated to within two sizes. Although there was a moderately strong correlation of 0.52 between templated and actual head sizes, this correlation was not demonstrated in femoral stem sizes. Mean leg length discrepancy was -2.5mm (S.D. 8.5), and the mean difference in femoral offset between the operated and non-operated hip was -1mm (S.D. 4.4). Digital templating is a useful adjunct to the surgeon in pre-operative planning of hip hemiarthroplasty in the restoration of leg length and femoral offset. However, its accuracy is inferior to that of elective total hip arthroplasty. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. [The incidence of osteopenia and osteoporosis in patients with cementless total hip arthroplasty].

    PubMed

    Lacko, M; Schreierová, D; Čellár, R; Vaško, G

    2015-01-01

    The aim of the study was to evaluate the incidence of osteopenia and osteoporosis in the patients elected to cementless total hip replacement. The group evaluated comprised 100 patients with primary or secondary forms of coxarthrosis who underwent cementless total hip arthroplasty (THA). The results of densitometric examination of the lumbar spine and proximal femur were analysed. Based on the lowest T-score value, the patients were divided into three groups, i.e., fist, normal bone density; second, osteopenia; third, osteoporosis. Clinical examination included patient medical history, Harris hip scores and visual analogue scale assessment for pain intensity; the Kellgren-Lawrence classification was used to measure the grade of hip osteoarthritis; blood tests were made to assess the levels of total calcium, ionised calcium, phosphorus, vitamin D and the markers of bone resorption and formation. Osteoporosis was found in 32 and osteopenia in 21 patients; 47 patients had normal bone density. Osteoporosis was detected in the lumbar spine of 21 patients, in the proximal femur of nine patients and at both sites in two patients. In 13 patients this diagnosis was made for the fist time. The patients with osteoporosis had a significantly lower body mass index. There were no differences in the other characteristics, i.e., age, functional, radiological and laboratory findings, among the groups; all three showed the mean vitamin D concentration below the lowest level of its physiological range. Insufficient vitamin D levels were found in 54 women and 18 men. Of all patients, only 13 women and four men took vitamin D supplements. DISCUSSION Osteoarthritis and osteoporosis are the most frequent complex musculoskeletal diseases. Several studies have suggested that these disorders are mutually exclusive. This assumption has been based on the absence of radiographic evidence of osteoarthritis seen in many elderly patients with femoral neck fractures. Our relatively frequent findings of osteopenia and osteoporosis in this study show that patients with osteoarthritis may not be protected from the development of generalised osteoporosis. Our results are compared with the relevant literature data and potential effects of osteoporosis and vitamin D deficiency on total hip arthroplasty are discussed. Hip osteoarthritis does not reduce the risk of generalised osteoporosis. We found a relative high incidence of osteopenia and osteoporosis as well as vitamin D deficiency in patient with advanced form of hip osteoarthritis.

  3. Predictors of perioperative blood loss in total joint arthroplasty.

    PubMed

    Park, Jai Hyung; Rasouli, Mohammad R; Mortazavi, S M Javad; Tokarski, Anthony T; Maltenfort, Mitchell G; Parvizi, Javad

    2013-10-02

    UPDATE The print version of this article has errors that have been corrected in the online version of this article. In the Materials and Methods section, the sentence that reads as "During the study period, our institution offered preoperative autologous blood donation to all patients who were scheduling for total joint arthroplasty with a hemoglobin level of no less than 11 mg/dL or a hematocrit level of at least 33%." in the print version now reads as "During the study period, our institution offered preoperative autologous blood donation to all patients who were scheduling for total joint arthroplasty with a hemoglobin level of no less than 11 g/dL or a hematocrit level of at least 33%." in the online version. In Table III, the footnote that reads as "The values are given as the estimate and the standard error in milligrams per deciliter." in the print version now reads as "The values are given as the estimate and the standard error in grams per deciliter." in the online version. Despite advances in surgical and anesthetic techniques, lower-extremity total joint arthroplasty is associated with considerable perioperative blood loss. As predictors of perioperative blood loss and allogenic blood transfusion have not yet been well defined, the purpose of this study was to identify clinical predictors for perioperative blood loss and allogenic blood transfusion in patients undergoing total joint arthroplasty. From 2000 to 2008, all patients undergoing unilateral primary total hip or knee arthroplasty who met the inclusion criteria were enrolled in the study. Perioperative blood loss was calculated with use of a previously validated formula. The predictors of perioperative blood loss and allogenic blood transfusion were identified in a multivariate analysis. Eleven thousand three hundred and seventy-three patients who underwent total joint arthroplasty, including 4769 patients who underwent total knee arthroplasty and 6604 patients who underwent total hip arthroplasty, were evaluated. Multivariate analysis indicated that an increase in blood loss was associated with being male (263.59 mL in male patients who had undergone total hip arthroplasty and 233.60 mL in male patients who had undergone total knee arthroplasty), a Charlson Comorbidity Index of >3 (293.99 mL in patients who had undergone total hip arthroplasty and 167.96 mL in patients who had undergone total knee arthroplasty), and preoperative autologous blood donation (593.51 mL in patients who had undergone total hip arthroplasty and 592.30 mL in patients who had undergone total knee arthroplasty). In patients who underwent total hip arthroplasty, regional anesthesia compared with general anesthesia reduced the amount of blood loss. The risk of allogenic blood transfusion increased with the amount of blood loss in the patients who underwent total hip arthroplasty (odds ratio, 1.43 [95% confidence interval, 1.40 to 1.46]) and the patients who underwent total knee arthroplasty (odds ratio, 1.47 [95% confidence interval, 1.42 to 1.51]), but the risk of blood transfusion increased with the Charlson Comorbidity Index only in patients who underwent total knee arthroplasty (odds ratio, 3.2 [95% confidence interval, 1.99 to 5.15]). The risk of allogenic blood transfusion decreased with preoperative autologous blood donation in patients who underwent total hip arthroplasty (odds ratio, 0.01 [95% confidence interval, 0.01 to 0.02]) and patients who underwent total knee arthroplasty (odds ratio, 0.02 [95% confidence interval, 0.01 to 0.03]). This study identified some clinical predictors for blood loss in patients undergoing total joint arthroplasty that we believe can be used for implementing more effective blood conservation strategies. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  4. Issues relating to long-term follow-up in hip arthroplasty surgery: a review of 598 cases at 7 years comparing 2 prostheses using revision rates, survival analysis, and patient-based measures.

    PubMed

    Dawson, J; Jameson-Shortall, E; Emerton, M; Flynn, J; Smith, P; Gundle, R; Murray, D

    2000-09-01

    We reviewed 598 cemented Charnley and Hi-nek total hip arthroplasties at 7 years. Data were obtained from general practitioners, hospital medical notes, microfilm, and patient questionnaires. Outcome measures were revision rates, survival analysis, 12-item Oxford Hip Score, and satisfaction ratings. There were 471 Charnley (79%) and 127 Hi-nek (21%) total hip arthroplasties; 139 deaths (23%) occurred, and 5 (<1%) were lost to follow-up. Characteristics of the Charnley and Hi-nek patient groups were similar, with more information missing for Charnley cases. Revision rates were Charnley, 37 (8%), and Hi-nek, 6 (5%) (not significant). Survival analysis revealed no difference between the 2 groups (P = .23). The patients' median Oxford Hip Score was low/good (19), slightly worse for the Hi-nek group (not significant). Taking all evidence together, neither implant was outperforming the other at 7 years.

  5. Revision for prosthetic joint infection following hip arthroplasty: Evidence from the National Joint Registry.

    PubMed

    Lenguerrand, E; Whitehouse, M R; Beswick, A D; Jones, S A; Porter, M L; Blom, A W

    2017-06-01

    We used the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man (NJR) to investigate the risk of revision due to prosthetic joint infection (PJI) for patients undergoing primary and revision hip arthroplasty, the changes in risk over time, and the overall burden created by PJI. We analysed revision total hip arthroplasties (THAs) performed due to a diagnosis of PJI and the linked index procedures recorded in the NJR between 2003 and 2014. The cohort analysed consisted of 623 253 index primary hip arthroplasties, 63 222 index revision hip arthroplasties and 7585 revision THAs performed due to a diagnosis of PJI. The prevalence, cumulative incidence functions and the burden of PJI (total procedures) were calculated. Overall linear trends were investigated with log-linear regression. We demonstrated a prevalence of revision THA due to prosthetic joint infection of 0.4/100 procedures following primary and 1.6/100 procedures following revision hip arthroplasty. The prevalence of revision due to PJI in the three months following primary hip arthroplasty has risen 2.3-fold (95% confidence interval (CI) 1.3 to 4.1) between 2005 and 2013, and 3.0-fold (95% CI 1.1 to 8.5) following revision hip arthroplasty. Over 1000 procedures are performed annually as a consequence of hip PJI, an increase of 2.6-fold between 2005 and 2013. Although the risk of revision due to PJI following hip arthroplasty is low, it is rising and, coupled with the established and further predicted increased incidence of both primary and revision hip arthroplasty, this represents a growing and substantial treatment burden. Cite this article : E. Lenguerrand, M. R. Whitehouse, A. D. Beswick, S. A. Jones, M. L. Porter, A. W. Blom. Revision for prosthetic joint infection following hip arthroplasty: Evidence from the National Joint Registry. Bone Joint Res 2017;6:391-398. DOI: 10.1302/2046-3758.66.BJR-2017-0003.R1. © 2017 Lenguerrand et al.

  6. Post-Discharge Care Duration, Charges, and Outcomes Among Medicare Patients After Primary Total Hip and Knee Arthroplasty.

    PubMed

    Ponnusamy, Karthikeyan E; Naseer, Zan; El Dafrawy, Mostafa H; Okafor, Louis; Alexander, Clayton; Sterling, Robert S; Khanuja, Harpal S; Skolasky, Richard L

    2017-06-07

    In April 2016, the U.S. Centers for Medicare & Medicaid Services initiated mandatory 90-day bundled payments for total hip and knee arthroplasty for much of the country. Our goal was to determine duration of care, 90-day charges, and readmission rates by discharge disposition and U.S. region after hip or knee arthroplasty. Using the 2008 Medicare Provider Analysis and Review database 100% sample, we identified patients who had undergone elective primary total hip or knee arthroplasty. We collected data on patient age, sex, comorbidities, U.S. Census region, discharge disposition, duration of care, 90-day charges, and readmission. Multivariate regression was used to assess factors associated with readmission (logistic) and charges (linear). Significance was set at p < 0.01. Patients undergoing 138,842 total hip arthroplasties were discharged to home (18%), home health care (34%), extended-care facilities (35%), and inpatient rehabilitation (13%); patients undergoing 329,233 total knee arthroplasties were discharged to home (21%), home health care (38%), extended-care facilities (31%), and inpatient rehabilitation (10%). Patients in the Northeast were more likely to be discharged to extended-care facilities or inpatient rehabilitation than patients in other regions. Patients in the West had the highest 90-day charges. Approximately 70% of patients were discharged home from extended-care facilities, whereas after inpatient rehabilitation, >50% of patients received home health care. Among those discharged to home, 90-day readmission rates were highest in the South (9.6%) for patients undergoing total hip arthroplasty and in the Midwest (8.7%) and the South (8.5%) for patients undergoing total knee arthroplasty. Having ≥4 comorbidities, followed by discharge to inpatient rehabilitation or an extended-care facility, had the strongest associations with readmission, whereas the region of the West and the discharge disposition to inpatient rehabilitation had the strongest association with higher charges. Among Medicare patients, discharge disposition and number of comorbidities were most strongly associated with readmission. Inpatient rehabilitation and the West region had the strongest associations with higher charges. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  7. Use of Hip Arthroscopy and Risk of Conversion to Total Hip Arthroplasty: A Population-Based Analysis.

    PubMed

    Schairer, William W; Nwachukwu, Benedict U; McCormick, Frank; Lyman, Stephen; Mayman, David

    2016-04-01

    To use population-level data to (1) evaluate the conversion rate of total hip arthroplasty (THA) within 2 years of hip arthroscopy and (2) assess the influence of age, arthritis, and obesity on the rate of conversion to THA. We used the State Ambulatory Surgery Databases and State Inpatient Databases for California and Florida from 2005 through 2012, which contain 100% of patient visits. Hip arthroscopy patients were tracked for subsequent primary THA within 2 years. Out-of-state patients and patients with less than 2 years follow-up were excluded. Multivariate analysis identified risks for subsequent hip arthroplasty after arthroscopy. We identified 7,351 patients who underwent hip arthroscopy with 2 years follow-up. The mean age was 43.9 ± 13.7 years, and 58.8% were female patients. Overall, 11.7% of patients underwent THA conversion within 2 years. The conversion rate was lowest in patients aged younger than 40 years (3.0%) and highest in the 60- to 69-year-old group (35.0%) (P < .001). We found an increased risk of THA conversion in older patients and in patients with osteoarthritis or obesity at the time of hip arthroscopy. Patients treated at high-volume hip arthroscopy centers had a lower THA conversion rate than those treated at low-volume centers (15.1% v 9.7%, P < .001). Hip arthroscopy is performed in patients of various ages, including middle-aged and elderly patients. Older patients have a higher rate of conversion to THA, as do patients with osteoarthritis or obesity. Level III, retrospective comparative study. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  8. Screws are not needed when secure interference fit of uncemented acetabular components is adequate: a 5- to 15-year follow-up with clinical and radiological analysis.

    PubMed

    García-Rey, Eduardo

    2017-05-12

    Even with good surgical preparation, adequate primary stability of the acetabular component is not always achieved after primary total hip replacement (THR). We hypothesise that adequate bone preparation for appropriate cortical loading would allow us to avoid screw use. A total of 791 uncemented cups were analysed to compare the need for screws to obtain primary fixation in 5 different designs. Arthritic hips with inflammatory arthritis or severe congenital hip disease were excluded. A press-fit technique was first tried in all hips and screws were only used when strictly needed. Radiological acetabular shape and postoperative cup position were assessed in all hips. The mean follow-up was 9.6 (5-15) years. Screws were required in 155 hips (19.6%). We could not detect any difference in the percentage of screw use between designs. We found that female patients (odds ratio [OR] 2.06; 95% confidence interval [CI], 1.41-3.02) and cups with a greater distance to the hip rotation centre on the postoperative radiograph (OR 1.69; 95% CI, 1.17-2.45) had a higher risk for screw use. A greater anteversion of the cup had a lower risk for screw use (OR 0.96; 95% CI, 0.94-0.99). At latest follow-up no hips had needed revision for aseptic loosening. Good intraoperative technique is not enough to avoid screw use since more accurate cup position and reconstruction of the hip rotation centre are required for an adequate interference fit. A press-fit technique can provide similar mid-term results to screw use in hips without severe deformities.

  9. The association between lower extremity energy absorption and biomechanical factors related to anterior cruciate ligament injury.

    PubMed

    Norcross, Marc F; Blackburn, J Troy; Goerger, Benjamin M; Padua, Darin A

    2010-12-01

    Greater total energy absorption by the lower extremity musculature during landing may reduce stresses placed on capsuloligamentous tissues with differences in joint contributions to energy absorption potentially affecting anterior cruciate ligament injury risk. However, the relationships between energy absorption and prospectively identified biomechanical factors associated with non-contact anterior cruciate ligament injury have yet to be demonstrated. Sagittal plane total, hip, knee and ankle energy absorption, and peak vertical ground reaction force, anterior tibial shear force, knee flexion and knee valgus angles, and internal hip extension and knee varus moments were measured in 27 individuals (14 females, 13 males) performing double leg jump landings. Correlation coefficients assessed the relationships between energy absorption during three time intervals (initial impact phase, terminal phase, and total landing) and biomechanical factors related to anterior cruciate ligament injury. More favorable values of biomechanical factors related to non-contact anterior cruciate ligament injury were associated with: 1) Lesser total (R(2)=0.178-0.558), hip (R(2)=0.229-0.651) and ankle (R(2)=0.280), but greater knee (R(2)=0.147) energy absorption during the initial impact phase; 2) Greater total (R(2)=0.170-0.845), hip (R(2)=0.599), knee (R(2)=0.236-0.834), and ankle (R(2)=0.276) energy absorption during the terminal phase of landing; and 3) Greater knee (R(2)=0.158-0.709), but lesser hip (R(2)=0.309) and ankle (R(2)=0.210-0.319) energy absorption during the total landing period. These results suggest that biomechanical factors related to anterior cruciate ligament injury are influenced by both the magnitude and timing of lower extremity energy absorption during landing. Copyright © 2010 Elsevier Ltd. All rights reserved.

  10. Elevated levels of numerous cytokines in drainage fluid after primary total hip arthroplasty.

    PubMed

    van der Heide, Huub J L; van der Kraan, Peter M; Rijnberg, Willard J; Buma, Pieter; Schreurs, B Willem

    2010-12-01

    As cytokines are involved in wound healing and other inflammatory processes, it could be valuable to measure their levels at the operative site. This study was conducted to investigate whether different cytokines are measurable in drainage fluid and, when measurable, whether we can find a difference in cytokine levels between one and six hours postoperatively. Samples from the drainage system in 30 consecutive patients undergoing primary total hip replacement were collected at one and six hours after closure of the wound. Levels of several cytokines were measured in the drainage fluids. A significant elevation of almost all cytokines was observed between the sample after one hour and six hours postoperatively. We found a strong correlation between the different pro-inflammatory cytokines. The IL-6 to IL-10 ratio were also raised, showing a pro-inflammatory predominance. Levels were much higher than those previously shown in serum.

  11. Pressure sores following elective total hip arthroplasty: pitfalls of misinterpretation.

    PubMed Central

    Keong, Nicole; Ricketts, David; Alakeson, Nuki; Rust, Philippa

    2004-01-01

    OBJECTIVE: To assess the reliability of reporting protocols regarding pressure sores. METHODS: Retrospective data were collected regarding pressure sore rates following total hip arthroplasty operations carried out during 2001 at two orthopaedic units in an NHS hospital (Princess Royal Hospital) and in a local private hospital. RESULTS: Preliminary results presented in audit and interim reports indicated an alarmingly high pressure sore rate across the two sites (17/172 [9.9%] NHS, 23/71 [32.4%] private hospital). On analysis, the data collection system was revealed to be flawed. Grade 1 areas (erythema with no ulceration) were included, leading to a dramatic discrepancy between reported and confirmed pressure sores. Re-analysis showed the confirmed pressure sore rates to be much lower (2.3% NHS, 1.0% private hospital). CONCLUSIONS: This audit suggests that both poor data collection and education lead to inaccurate audit. This may lead to subsequent inappropriate management and inappropriate NHS star ratings. PMID:15140301

  12. Ultrasound screening of periarticular soft tissue abnormality around metal-on-metal bearings.

    PubMed

    Nishii, Takashi; Sakai, Takashi; Takao, Masaki; Yoshikawa, Hideki; Sugano, Nobuhiko

    2012-06-01

    Although metal hypersensitivity or pseudotumors are concerns for metal-on-metal (MoM) bearings, detailed pathologies of patterns, severity, and incidence of periprosthetic soft tissue lesions are incompletely understood. We examined the potential of ultrasound for screening of periarticular soft tissue lesions around MoM bearings. Ultrasound examinations were conducted in 88 hips (79 patients) with MoM hip resurfacings or MoM total hip arthroplasties with a large femoral head. Four qualitative ultrasound patterns were shown, including normal pattern in 69 hips, joint-expansion pattern in 11 hips, cystic pattern in 5 hips, and mass pattern in 3 hips. Hips with the latter 3 abnormal patterns showed significantly higher frequency of clinical symptoms, without significant differences of sex, duration of implantation, head sizes, and cup abduction/anteversion angles, compared with hips with normal pattern. Ultrasound examination provides sensitive screening of soft tissue reactions around MoM bearings and may be useful in monitoring progression and defining treatment for periarticular soft tissue abnormalities. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Can Arthroplasty Stem INfluence Outcome? (CASINO): a randomized controlled equivalence trial of 125 mm versus 150 mm Exeter V40 stems in total hip arthroplasty.

    PubMed

    Hamilton, David F; Ohly, Nicholas E; Gaston, Paul

    2018-04-16

    The use of shorter length femoral stems during total hip arthroplasty has been suggested to accommodate wider patient femoral geometry and offer maximal bone preservation. However, cemented short-stem designs may increase the risk of varus stem malalignment and influence patient outcomes. CASINO is a multi-centre randomised equivalence trial that will recruit 220 patients undergoing total hip arthroplasty for osteoarthritis at two NHS hospitals in Scotland. Patients will be aged 45-80, undergoing unilateral primary hip arthroplasty, with no plan for contralateral procedure within the study timeframe, and able to comply with the protocol. Participants will be randomised to receive either a short (125 mm) or a standard (150 mm) Exeter V40 stem. The Contemporary acetabular component will be used in all cases. All implants will be cemented. Patient pain, function and satisfaction will be assessed using change from baseline measurement in Oxford Hip Score, Forgotten Joint Score, EQ-5D, pain numerical rating scores, and patient satisfaction questionnaire at baseline and at 1 and 2 years following surgery. Radiographic assessment will evaluate stem position and will be appraised by independent reviewers. Patients will be blind to implant allocation. Stem length may be associated with outcome; however, we can find no randomised trial in which researchers investigated the effect of stem length on patient outcome following cemented total hip arthroplasty. The aim of this trial is to determine if the use of short cemented stems offers equivalent patient outcomes to those achieved following surgery with standard length stems. International Standard Randomised Controlled Trial Number, ISRCTN13154542 , Registered on 30 June 2017.

  14. Photobiomodulation therapy (PBMT) on acute pain and inflammation in patients who underwent total hip arthroplasty-a randomized, triple-blind, placebo-controlled clinical trial.

    PubMed

    Langella, Luciana Gonçalves; Casalechi, Heliodora Leão; Tomazoni, Shaiane Silva; Johnson, Douglas Scott; Albertini, Regiane; Pallotta, Rodney Capp; Marcos, Rodrigo Labat; de Carvalho, Paulo de Tarso Camillo; Leal-Junior, Ernesto Cesar Pinto

    2018-06-16

    When conservative treatments fail, hip osteoarthritis (OA), a chronic degenerative disease characterized by cartilage wear, progressive joint deformity, and loss of function, can result in the need for a total hip arthroplasty (THA). Surgical procedures induced tissue trauma and incite an immune response. Photobiomodulation therapy (PBMt) using low-level laser therapy (LLLT) and/or light-emitting diode therapy (LEDT) has proven effective in tissue repair by modulating the inflammatory process and promoting pain relief. Therefore, the aim of this study was to analyze the immediate effect of PBMt on inflammation and pain of patients undergoing total hip arthroplasty. The study consisted of 18 post-surgical hip arthroplasty patients divided into two groups (n = 9 each) placebo and active PBMt who received one of the treatments in a period from 8 to 12 h following THA surgery. PBMt (active or placebo) was applied using a device consisting of nine diodes (one super-pulsed laser of 905 nm, four infrared LEDs of 875 nm, and four red LEDs 640 nm, 40.3 J per point) applied to 5 points along the incision. Visual analog scale (VAS) and blood samples for analysis of the levels of the cytokines TNF-α, IL-6, and IL-8 were recorded before and after PBMt application. The values for the visual analog scale as well as those in the analysis of TNF-α and IL-8 serum levels decreased in the active PBMt group compared to placebo-control group (p < 0.05). No decrease was observed for IL-6 levels. We conclude that PBMt is effective in decreasing pain intensity and post-surgery inflammation in patients receiving total hip arthroplasty.

  15. Large femoral heads decrease the incidence of dislocation after total hip arthroplasty: a randomized controlled trial.

    PubMed

    Howie, Donald W; Holubowycz, Oksana T; Middleton, Robert

    2012-06-20

    The use of larger femoral heads has been proposed to reduce the risk of dislocation after total hip arthroplasty, but there is a lack of evidence to support this proposal. The aim of this multicenter randomized controlled trial was to determine whether the incidence of dislocation one year after total hip arthroplasty is significantly lower in association with the use of a 36-mm femoral head articulation as compared with a 28-mm articulation. Six hundred and forty-four middle-aged and elderly patients undergoing primary or revision arthroplasty were randomized intraoperatively to receive either a 36 or 28-mm metal femoral head on highly cross-linked polyethylene. Patients who were at high risk of dislocation (including those with dementia and neuromuscular disease) and those undergoing revision for the treatment of recurrent hip dislocation or infection were excluded. Patients were stratified according to other potential risk factors for dislocation, including diagnosis and age. Diagnosis of hip dislocation required confirmation by a physician and radiographic evidence of a dislocation. Overall, at one year of follow-up, hips with a 36-mm femoral head articulation had a significantly lower incidence of dislocation than did those with a 28-mm articulation (1.3% [four of 299] compared with 5.4% [seventeen of 316]; difference, 4.1% [95% confidence interval, 1.2% to 7.2%]) when controlling for the type of procedure (primary or revision) (p = 0.012). The incidence of dislocation following primary arthroplasty was also significantly lower for hips with a 36-mm femoral head articulation than for those with a 28-mm articulation (0.8% [two of 258] compared with 4.4% [twelve of 275]; difference, 3.6% [95% confidence interval, 0.9% to 6.8%]) (p = 0.024). The incidence of dislocation following revision arthroplasty was 4.9% (two of forty-one) for hips with a 36-mm articulation and 12.2% (five of forty-one) for hips with a 28-mm articulation; this difference was not significant with the relatively small sample size of the revision group (difference, 7.3% [95% confidence interval, -5.9% to 21.1%]) (p = 0.273). Compared with a 28-mm femoral head articulation, a larger 36-mm articulation resulted in a significantly decreased incidence of dislocation in the first year following primary total hip arthroplasty. However, before a 36-mm metal-on-highly cross-linked polyethylene articulation is widely recommended, the incidence of late dislocation, wear, periprosthetic osteolysis, and liner fracture should be established.

  16. Reduced survival for uncemented compared to cemented total hip arthroplasty after operatively treated acetabular fractures.

    PubMed

    Clarke-Jenssen, John; Westberg, Marianne; Røise, Olav; Storeggen, Stein Arne Øvre; Bere, Tone; Silberg, Ingunn; Madsen, Jan Erik

    2017-11-01

    Post traumatic arthritis and avascular necrosis of the femoral head are common complications after operatively treated acetabular fractures. This may cause severe disabilities for the patient, necessitating a total hip arthroplasty. Even though an arthroplasty may provide good symptomatic relief, the long-term results are more uncertain and no consensus exists according to preferred prosthetic designs. With this cohort study, we aimed to investigate the medium to long term arthroplasty survival and clinical results of total hip arthroplasty after operatively treated acetabular fractures. We included 52 patients treated with a secondary total hip arthroplasty at a median of 2.4 (0.1-14.1) years after an operatively treated acetabular fracture. The median age was 54 (11-82) years. Cemented arthroplasty was used for 33 patients, 10 patients had an uncemented arthroplasty and 9 patients received a hybrid arthroplasty. Average follow up was 8.0 (SD 5.0) years. Ten-year revision free arthroplasty survival was 79%. Uncemented arthroplasties had a significantly worse 10-year survival of 57%. Arthroplasties performed at a centre without a pelvic fracture service also had a significantly worse 10-years survival of 51%. Cox regression showed similar results with an 8-fold increase in risk of revision for both uncemented arthroplasties and operations performed at a non-pelvic trauma centre. Total hip arthroplasty secondary to an operatively treated acetabular fracture provides good symptomatic relief. These patients are, however, complex cases and are probably best treated at specialist centres with both pelvic trauma surgeons and arthroplasty surgeons proficient in complex revisions present. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Handball Practice Enhances Bone Mass in Specific Sites Among Prepubescent Boys.

    PubMed

    Missawi, Kawther; Zouch, Mohamed; Chakroun, Yosra; Chaari, Hamada; Tabka, Zouhair; Bouajina, Elyès

    2016-01-01

    This investigation's purpose is to focus on the effects of practicing handball for at least 2 yr on bone acquisition among prepubescent boys. One hundred prepubescent boys aged 10.68 ± 0.85 yr were divided into 2 groups: 50 handball players (HP group) and 50 controls (C group). Bone mineral density (BMD), bone mineral content (BMC), and bone area (BA) were evaluated by using dual-photon X-ray absorptiometry on the whole body, lumbar spine (L2-L4), legs, arms, femoral necks, hips and radiuses. Results showed greater values of BMD in both right and left femoral neck and total hip in handball players than in controls. In addition, handball players had higher values of legs and right total hip BMC than controls without any obvious variation of BA measurement in all sites between groups. All results of the paired t-test displayed an obviously marked variation of bone mass parameters between the left and right sides in the trained group without any marked variation among controls. Data showed an increased BMD of the supporting sites between the left and the right leg among handball players. However, "BMC" results exhibited higher values in the right than in the left total hip, and in the right total radius than in the left correspondent site. In addition, differences in the "BA" measurements were observed in the left total hip and in the right arm. Specific bone sites are markedly stimulated by handball training in prepubescent boys. Copyright © 2016 International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  18. [Effectiveness of multiple small-diameter drilling decompression combined with hip arthroscopy for early osteonecrosis of the femoral head].

    PubMed

    Li, Ji; Li, Zhongli; Su, Xiangzheng; Liu, Chunhui; Zhang, Hao; Wang, Ketao

    2017-09-01

    To evaluate the effectiveness of multiple small-diameter drilling decompression combined with hip arthroscopy for early oeteonecrosis of the femoral head (ONFH). Between March 2010 and December 2013, 91 patients with early ONFH were treated with the operation of multiple small-diameter drilling decompression combined with hip arthroscopy in 39 cases (53 hips, group A) or with drilling decompression alone in 52 cases (74 hips, group B). The patients in 2 groups had obvious hip pain and limited motion before operation. There was no significant difference in gender, age, etiology, effected side, stage of osteonecrosis, and preoperative Harris score between 2 groups ( P >0.05). All operations succeeded and all incisions healed by first intention. The operation time was significantly longer in group A [(73.3±10.6) minutes] than in group B [(41.5±7.2) minutes] ( t =8.726, P =0.000). Temporary of sciatic nerve apraxia after operation occurred in 2 patients of group A, and no complication occurred in other patients. Patients were followed up 24-52 months (mean, 39.3 months) in group A and 24-48 months (mean, 34.6 months) in group B. At last follow-up, the Harris scores were 83.34±8.76 in group A and 76.61±9.22 in group B, showing significant differences when compared between 2 groups ( t =-4.247, P =0.029) and when compared with preoperative values in 2 groups ( t =-10.327, P =0.001; t =-8.216, P =0.008). X-ray films showed that the collapse of the femoral head was observed in 6 hips (1 hip at stage Ⅰand 5 hips at stage Ⅱ) in group A, and in 16 hips (4 hips at stageⅠand 12 hips at stage Ⅱ) in group B; and hip arthroplasty was performed. The total effective rates were 88.68% (47/53) in group A and 78.38% (58/74) in group B, respectively; showing significant difference between 2 groups ( χ 2 =5.241, P =0.041). Multiple small-diameter drilling decompression combined with hip arthroscopy is effective in pain relief, improvement of hip function, slowing-down the process of femoral head necrosis, delaying the need for total hip arthroplasty in patients with early ONFH.

  19. Energy Absorption Contribution and Strength in Female Athletes at Return to Sport After Anterior Cruciate Ligament Reconstruction: Comparison With Healthy Controls.

    PubMed

    Boo, Marie E; Garrison, J Craig; Hannon, Joseph P; Creed, Kalyssa M; Goto, Shiho; Grondin, Angellyn N; Bothwell, James M

    2018-03-01

    Female patients are more likely to suffer a second anterior cruciate ligament (ACL) injury after ACL reconstruction (ACLR) and return to sport (RTS) compared with healthy female controls. Few studies have examined the energy absorption contribution (EAC) that could lead to this subsequent injury. The ACLR group would demonstrate an altered EAC between joints (hip, knee, and ankle) but no difference in quadriceps, hip abduction, or hip external rotation (ER) strength at the time of RTS. Cross-sectional study; Level of evidence, 3. A total of 34 female participants (ACLR: n = 17; control: n = 17) were enrolled in the study and matched for age and activity level. Jump landing performance for the initial 50 milliseconds of landing of a lateral-vertical jump was assessed using a 10-camera 3-dimensional motion capture system and 2 force plates. Isokinetic quadriceps strength was measured using a Biodex machine, and hip abduction and ER isometric strength were measured using a handheld dynamometer. All values were normalized to the participant's height and weight. A 1-way multivariate analysis of variance was used to assess between-group differences in the EAC at the hip, knee, and ankle. Two 1-way analyses of variance were used to independently examine quadriceps, hip abduction, and hip ER strength between the groups. Significant differences in the EAC were found between the groups for the involved hip ( P = .002), uninvolved hip ( P = .005), and involved ankle ( P = .023). There were no between-group differences in the EAC for the involved or uninvolved knee or the uninvolved ankle. Patients who underwent ACLR demonstrated significantly decreased quadriceps strength on the involved limb ( P = .02) and decreased hip ER strength on both the involved ( P = .005) and uninvolved limbs ( P = .002). No significant strength differences were found between the groups for the uninvolved quadriceps or for involved or uninvolved hip abduction. At RTS, patients who underwent ACLR utilized a greater hip EAC bilaterally and a decreased involved ankle EAC during a lateral-vertical jump. Furthermore, quadriceps strength on the involved limb and hip ER strength of bilateral lower extremities remained decreased. This could place greater stress on the ACL graft and ultimately lead to an increased injury risk.

  20. Energy Absorption Contribution and Strength in Female Athletes at Return to Sport After Anterior Cruciate Ligament Reconstruction: Comparison With Healthy Controls

    PubMed Central

    Boo, Marie E.; Garrison, J. Craig; Hannon, Joseph P.; Creed, Kalyssa M.; Goto, Shiho; Grondin, Angellyn N.; Bothwell, James M.

    2018-01-01

    Background: Female patients are more likely to suffer a second anterior cruciate ligament (ACL) injury after ACL reconstruction (ACLR) and return to sport (RTS) compared with healthy female controls. Few studies have examined the energy absorption contribution (EAC) that could lead to this subsequent injury. Hypothesis: The ACLR group would demonstrate an altered EAC between joints (hip, knee, and ankle) but no difference in quadriceps, hip abduction, or hip external rotation (ER) strength at the time of RTS. Study Design: Cross-sectional study; Level of evidence, 3. Methods: A total of 34 female participants (ACLR: n = 17; control: n = 17) were enrolled in the study and matched for age and activity level. Jump landing performance for the initial 50 milliseconds of landing of a lateral-vertical jump was assessed using a 10-camera 3-dimensional motion capture system and 2 force plates. Isokinetic quadriceps strength was measured using a Biodex machine, and hip abduction and ER isometric strength were measured using a handheld dynamometer. All values were normalized to the participant’s height and weight. A 1-way multivariate analysis of variance was used to assess between-group differences in the EAC at the hip, knee, and ankle. Two 1-way analyses of variance were used to independently examine quadriceps, hip abduction, and hip ER strength between the groups. Results: Significant differences in the EAC were found between the groups for the involved hip (P = .002), uninvolved hip (P = .005), and involved ankle (P = .023). There were no between-group differences in the EAC for the involved or uninvolved knee or the uninvolved ankle. Patients who underwent ACLR demonstrated significantly decreased quadriceps strength on the involved limb (P = .02) and decreased hip ER strength on both the involved (P = .005) and uninvolved limbs (P = .002). No significant strength differences were found between the groups for the uninvolved quadriceps or for involved or uninvolved hip abduction. Conclusion: At RTS, patients who underwent ACLR utilized a greater hip EAC bilaterally and a decreased involved ankle EAC during a lateral-vertical jump. Furthermore, quadriceps strength on the involved limb and hip ER strength of bilateral lower extremities remained decreased. This could place greater stress on the ACL graft and ultimately lead to an increased injury risk. PMID:29552573

  1. Effect of body mass index on functional outcomes following arthroplasty procedures.

    PubMed

    Polat, Gokhan; Ceylan, Hasan Huseyin; Sayar, Safak; Kucukdurmaz, Fatih; Erdil, Mehmet; Tuncay, Ibrahim

    2015-12-18

    To evaluate the body mass index (BMI) change in arthroplasty patients and its impact on the patients' functional results. Between October 2010 and May 2013, 606 patients who were operated due to gonarthrosis, coxarthrosis, aseptic loosening of the total knee and hip prosthesis were evaluated prospectively. Patients were operated by three surgeons in three medical centers. Patients who were between 30-90 years of age and who were underwent total knee arthroplasty, total hip arthroplasty, revision knee arthroplasty, or revision hip arthroplasty were included in the study. We excluded the patients who cannot tolerate our standard postoperative rehabilitation program. Additionally, patients who had systemic inflammatory diseases, diabetes mellitus, or endochrinopathies were excluded from the study. The remaining 513 patients comprised our study group. Preoperative functional joint scores, height, weight and BMI of all patients were recorded. We used the Knee Society Score (KSS) for knee and Harris Hip Score (HHS) for hip patients. Postoperative functional scores were measured at 1(st), 6(th) and 12(th) months and recorded separately at outpatient visits. The mean age of the patients was 64.7 (range: 30-90) years (207 males/306 females) and the mean follow-up duration was 14.3 (range: 12-26) mo. We found that arthroplasty patients had weight gain and had an increase in BMI at the postoperative 1(st), 6(th) and 12(th) months. The mean BMI of the patients was 27.7 preoperatively, 27.8 at the postoperative 1(st) month, 28.1 at the 6(th) month and 28.6 at the 12(th) month (P < 0.01). At the last visit, the mean postoperative HHS of the hip arthroplasty patients was 82.2 ± 7.12 (preoperatively, 52.3; 1(st) month, 78.2; 6(th) month, 81.1; 12(th) month, 82.2), and the mean KSS of the knee arthroplasty patients was 79.3 ± 4.31 (preoperatively, 35.8; 1(st) month, 75.2; 6(th) month, 79.1; 12(th) month, 79.3). Worse functional results were noted in the patients who had a BMI increase, however, this correlation was statistically significant only at the postoperative 6(th) month (P = 0.03). To prevent the negative functional effects of this weight gain during the postoperative period, arthroplasty patients should be advised for weight control and risky patients should consult with a dietician.

  2. The Exercise Plus Program for Older Women Post Hip Fracture: Participant Perspectives

    ERIC Educational Resources Information Center

    Resnick, Barbara; Orwig, Denise; Wehren, Lois; Zimmerman, Sheryl; Simpson, Marjorie; Magaziner, Jay

    2005-01-01

    Purpose: The purpose of this study was to explore the experiences of older women post hip fracture who were exposed to a motivational intervention, the Exercise Plus Program, intended to increase adherence to exercise. Design and Methods: This study used a naturalistic inquiry. We interviewed a total of 70 older women, 12 months post hip fracture,…

  3. Effect of cup inclination on predicted contact stress-induced volumetric wear in total hip replacement.

    PubMed

    Rijavec, B; Košak, R; Daniel, M; Kralj-Iglič, V; Dolinar, D

    2015-01-01

    In order to increase the lifetime of the total hip endoprosthesis, it is necessary to understand mechanisms leading to its failure. In this work, we address volumetric wear of the artificial cup, in particular the effect of its inclination with respect to the vertical. Volumetric wear was calculated by using mathematical models for resultant hip force, contact stress and penetration of the prosthesis head into the cup. Relevance of the dependence of volumetric wear on inclination of the cup (its abduction angle ϑA) was assessed by the results of 95 hips with implanted endoprosthesis. Geometrical parameters obtained from standard antero-posterior radiographs were taken as input data. Volumetric wear decreases with increasing cup abduction angle ϑA. The correlation within the population of 95 hips was statistically significant (P = 0.006). Large cup abduction angle minimises predicted volumetric wear but may increase the risk for dislocation of the artificial head from the cup in the one-legged stance. Cup abduction angle and direction of the resultant hip force may compensate each other to achieve optimal position of the cup with respect to wear and dislocation in the one-legged stance for a particular patient.

  4. Achieving Consensus on Total Joint Replacement Trial Outcome Reporting Using the OMERACT Filter: Endorsement of the Final Core Domain Set for Total Hip and Total Knee Replacement Trials for Endstage Arthritis.

    PubMed

    Singh, Jasvinder A; Dowsey, Michelle M; Dohm, Michael; Goodman, Susan M; Leong, Amye L; Scholte Voshaar, Marieke M J H; Choong, Peter F

    2017-11-01

    Discussion and endorsement of the OMERACT total joint replacement (TJR) core domain set for total hip replacement (THR) and total knee replacement (TKR) for endstage arthritis; and next steps for selection of instruments. The OMERACT TJR working group met at the 2016 meeting at Whistler, British Columbia, Canada. We summarized the previous systematic reviews, the preliminary OMERACT TJR core domain set and results from previous surveys. We discussed preliminary core domains for TJR clinical trials, made modifications, and identified challenges with domain measurement. Working group participants (n = 26) reviewed, clarified, and endorsed each of the inner and middle circle domains and added a range of motion domain to the research agenda. TJR were limited to THR and TKR but included all endstage hip and knee arthritis refractory to medical treatment. Participants overwhelmingly endorsed identification and evaluation of top instruments mapping to the core domains (100%) and use of subscales of validated multidimensional instruments to measure core domains for the TJR clinical trial core measurement set (92%). An OMERACT core domain set for hip/knee TJR trials has been defined and we are selecting instruments to develop the TJR clinical trial core measurement set to serve as a common foundation for harmonizing measures in TJR clinical trials.

  5. Association of Body Weight and Body Mass Index with Bone Mineral Density in Women and Men from Kosovo.

    PubMed

    Rexhepi, Sylejman; Bahtiri, Elton; Rexhepi, Mjellma; Sahatciu-Meka, Vjollca; Rexhepi, Blerta

    2015-08-01

    Body weight and body mass index (BMI) are considered potentially modifiable determinants of bone mass. Therefore, the aim of this study was to explore the association between body weight and body mass index (BMI) with total hip and lumbar spine bone mineral density (BMD). This cross-sectional study included a population of 100 women and 32 men from Kosovo into three BMI groups. All the study subjects underwent dual-energy X-ray absorptiometry (DXA) measurements. Total hip BMD levels of obese menopausal and premenopausal women and men were significantly higher compared to overweight or normal weight subjects, while lumbar spine BMD levels of only menopausal women and men were higher among obese subjects. Age-adjusted linear regression analysis showed that BMI is a significant independent associate of lumbar spine and total hip BMD in menopausal women and men. Despite positive association between BMI and lumbar spine and total hip BMD in menopausal women, presence of more obese and osteoporotic subjects among menopausal women represent a population at risk for fractures because of poor balance and frequent falls; therefore, both obesity and osteoporosis prevention efforts should begin early on in life.

  6. Revision surgery of metal-on-metal hip arthroplasties for adverse reactions to metal debris.

    PubMed

    Matharu, Gulraj S; Eskelinen, Antti; Judge, Andrew; Pandit, Hemant G; Murray, David W

    2018-06-01

    Background and purpose - The initial outcomes following metal-on-metal hip arthroplasty (MoMHA) revision surgery performed for adverse reactions to metal debris (ARMD) were poor. Furthermore, robust thresholds for performing ARMD revision are lacking. This article is the second of 2. The first article considered the various investigative modalities used during MoMHA patient surveillance (Matharu et al. 2018a ). The present article aims to provide a clinical update regarding ARMD revision surgery in MoMHA patients (hip resurfacing and large-diameter MoM total hip arthroplasty), with specific focus on the threshold for performing ARMD revision, the surgical strategy, and the outcomes following revision. Results and interpretation - The outcomes following ARMD revision surgery appear to have improved with time for several reasons, among them the introduction of regular patient surveillance and lowering of the threshold for performing revision. Furthermore, registry data suggest that outcomes following ARMD revision are influenced by modifiable factors (type of revision procedure and bearing surface implanted), meaning surgeons could potentially reduce failure rates. However, additional large multi-center studies are needed to develop robust thresholds for performing ARMD revision surgery, which will guide surgeons' treatment of MoMHA patients. The long-term systemic effects of metal ion exposure in patients with these implants must also be investigated, which will help establish whether there are any systemic reasons to recommend revision of MoMHAs.

  7. [Minimally invasive approaches to hip and knee joints for total joint replacement].

    PubMed

    Rittmeister, M; König, D P; Eysel, P; Kerschbaumer, F

    2004-11-01

    The manuscript features the different minimally invasive approaches to the hip for joint replacement. These include medial, anterior, anterolateral, and posterior approaches. The concept of minimally invasive hip arthroplasty makes sense if it is an integral part of a larger concept to lower postoperative morbidity. Besides minimal soft tissue trauma, this concept involves preoperative patient education, preemptive analgesia, and postoperative physiotherapy. It is our belief that minimal incision techniques for the hip are not suited for all patients and all surgeons. The different minimally invasive approaches to the knee joint for implantation of a knee arthroplasty are described and discussed. There have been no studies published yet that fulfill EBM criteria. The data so far show that minimally invasive approaches and implantation techniques for total knee replacements lead to quicker rehabilitation of patients.

  8. Survivorship of the native hip joint after percutaneous repair of acetabular fractures in the elderly.

    PubMed

    Gary, Joshua L; Lefaivre, Kelly A; Gerold, Frank; Hay, Michael T; Reinert, Charles M; Starr, Adam J

    2011-10-01

    Our purpose was to examine survivorship of the native hip joint in patients ages 60 and over who underwent percutaneous reduction and fixation of acetabular fractures. A retrospective review at a University Level I Trauma Center was performed. Our institutional trauma database was reviewed. Patients aged 60 or older treated with percutaneous reduction and fixation of acetabular fractures between 1994 and 2007 were selected. 79 consecutive patients with 80 fractures were identified. Rate of conversion to total hip arthroplasty were used to construct a Kaplan-Meier curve showing survivorship of the native hip joint after treatment. 75 fractures had adequate clinical follow-up with a mean of 3.9 years (range 0.5-11.9 years). Average blood loss was 69 cc and there were no postoperative infections. 19/75 (25%) were converted to total hip arthroplasty at a mean time of 1.4 years after the index procedure. Survivorship analysis demonstrated a cumulative survival of 65% at 11.9 years of follow-up. There were no conversions to arthroplasty beyond 4.7 years postoperatively. There were no statistically significant associations between conversion to arthroplasty and age, sex, closed vs. limited open reduction, and simple vs. complex fracture pattern. Percutaneous fixation is a viable treatment option for patients age 60 or greater with acetabular fractures. Rates of conversion to total hip arthroplasty are comparable to open treatment methods and if conversion is required, soft tissues are preserved for future surgery. Copyright © 2010 Elsevier Ltd. All rights reserved.

  9. Early failure of total hip replacements implanted at distant hospitals to reduce waiting lists.

    PubMed Central

    Ciampolini, Jac; Hubble, Matthew J. W.

    2005-01-01

    AIM: In the years 1990-1993, in an effort to reduce waiting-list time, a small number of patients were sent from Exeter to hospitals in London to undergo elective total hip replacement. No medium- or long-term follow-up was arranged. Our aim was to audit the outcome of these hip replacements. PATIENTS AND METHODS: Review of the records of the referring medical practices, Regional Health Authority, local orthopaedic hospital and the distant centres at which the surgery was performed identified 31 cases. A total of 27 hip replacements in 24 patients were available for clinical and radiological review. RESULTS: 12 (44%) hips have so far required revision surgery, at a mean of 6.5 years. Of these, three (11%) have been for deep infection. A further three hips (11%) are radiologically loose and are being closely monitored. Two patients (7%) suffered permanent sciatic nerve palsy. CONCLUSIONS: Patients whose surgery was performed locally over a similar time period have a published failure rate of only 4.9%. This difference is highly statistically significant (P < 0.001). The causes for such a difference in outcome were analysed and include surgical technique, implant selection and absence of follow-up. In the light of this evidence, we would like to urge the government to address waiting list problems by investing in the local infrastructure. Expanding those facilities where properly audited and fully accountable surgeons operate must be the way forward. PMID:15720905

  10. Celecoxib versus ibuprofen in the prevention of heterotopic ossification following total hip replacement: a prospective randomised trial.

    PubMed

    Saudan, M; Saudan, P; Perneger, T; Riand, N; Keller, A; Hoffmeyer, P

    2007-02-01

    We examined whether a selective cyclooxygenase-2 (COX-2) inhibitor (celecoxib) was as effective as a non-selective inhibitor (ibuprofen) for the prevention of heterotopic ossification following total hip replacement. A total of 250 patients were randomised to receive celecoxib (200 mg b/d) or ibuprofen (400 mg t.d.s) for ten days after surgery. Anteroposterior radiographs of the pelvis were examined for heterotopic ossification three months after surgery. Of the 250 patients, 240 were available for assessment. Heterotopic ossification was more common in the ibuprofen group (none 40.7% (50), Brooker class I 46.3% (57), classes II and III 13.0% (16)) than in the celecoxib group (none 59.0% (69), Brooker class I 35.9% (42), classes II and III 5.1% (6), p=0.002). Celecoxib was more effective than ibuprofen in preventing heterotopic bone formation after total hip replacement.

  11. Hip protector compliance: a 13-month study on factors and cost in a long-term care facility.

    PubMed

    Burl, Jeffrey B; Centola, James; Bonner, Alice; Burque, Colleen

    2003-01-01

    To determine if a high compliance rate for wearing external hip protectors could be achieved and sustained in a long-term care population. A 13-month prospective study of daytime use of external hip protectors in an at-risk long-term care population. One hundred-bed not-for-profit long-term care facility. Thirty-eight ambulatory residents having at least 1 of 4 risk factors (osteoporosis, recent fall, positive fall screen, previous fracture). The rehabilitation department coordinated an implementation program. Members of the rehabilitation team met with eligible participants, primary caregivers, families, and other support staff for educational instruction and a description of the program. The rehabilitation team assumed overall responsibility for measuring and ordering hip protectors and monitoring compliance. By the end of the third month, hip protector compliance averaged greater than 90% daily wear. The average number of falls per month in the hip protector group was 3.9 versus 1.3 in nonparticipants. Estimated total indirect staff time was 7.75 hours. The total cost of the study (hip protectors and indirect staff time) was 6,300 US dollars. High hip protector compliance is both feasible and sustainable in an at-risk long-term care population. Achieving high compliance requires an interdisciplinary approach with one department acting as a champion. The cost of protectors could be a barrier to widespread use. Facilities might be unable to cover the cost until the product is paid for by third-party payers.

  12. Effectiveness of multimodal pain management after bipolar hemiarthroplasty for hip fracture: a randomized, controlled study.

    PubMed

    Kang, Hyun; Ha, Yong-Chan; Kim, Jin-Yun; Woo, Young-Cheol; Lee, Jae-Sung; Jang, Eui-Chan

    2013-02-20

    Appropriate pain management affects outcome after hip fracture surgery. Although multimodal pain management is commonly used for pain control for patients undergoing elective surgery, few studies have evaluated its use in those undergoing hip fracture surgery. This prospective randomized study was designed to determine the clinical value of multimodal pain management with preemptive pain medication and intraoperative periarticular multimodal drug injections in patients undergoing bipolar hip hemiarthroplasty. Of eighty-two cognitively intact elderly patients about to undergo bipolar hemiarthroplasty after a hip fracture, forty-three were randomly assigned to receive preemptive pain medication and intraoperative periarticular injections (Group I) and thirty-nine were assigned to not receive preemptive medication and injections (Group II). These two groups were compared with regard to the pain level on postoperative days one, four, and seven; at discharge; and when they started walking and standing exercises. Total amounts of fentanyl used, the frequency of use of patient-controlled analgesia, patient satisfaction at discharge, and perioperative complications were recorded. Group I had a lower pain level than Group II on postoperative days one and four, but no intergroup difference in pain level was observed on postoperative day seven. The total amount of fentanyl used and the frequency of use of patient-controlled analgesia were also lower in Group I. Patient satisfaction at discharge was higher in Group I. No significant intergroup differences were found in the times until the patients walked or performed standing exercises or in the complications. Multimodal pain management provides additional pain relief until the fourth postoperative day, improves patient satisfaction at discharge, and reduces total narcotic consumption for postoperative pain management after hip hemiarthroplasty for hip fractures.

  13. Bone marrow edema pattern in advanced hip osteoarthritis: quantitative assessment with magnetic resonance imaging and correlation with clinical examination, radiographic findings, and histopathology.

    PubMed

    Taljanovic, Mihra S; Graham, Anna R; Benjamin, James B; Gmitro, Arthur F; Krupinski, Elizabeth A; Schwartz, Stephanie A; Hunter, Tim B; Resnick, Donald L

    2008-05-01

    To correlate the amount of bone marrow edema (BME) calculated by magnetic resonance imaging(MRI) with clinical findings, histopathology, and radiographic findings, in patients with advanced hip osteoarthritis(OA). The study was approved by The Institutional Human Subject Protection Committee. Coronal MRI of hips was acquired in 19 patients who underwent hip replacement. A spin echo (SE) sequence with four echoes and separate fast spin echo (FSE) proton density (PD)-weighted SE sequences of fat (F) and water (W) were acquired with water and fat suppression, respectively. T2 and water:fat ratio calculations were made for the outlined regions of interest. The calculated MRI values were correlated with the clinical, radiographic, and histopathologic findings. Analyses of variance were done on the MRI data for W/(W + F) and for T2 values (total and focal values) for the symptomatic and contralateral hips. The values were significantly higher in the study group. Statistically significant correlations were found between pain and total W/(W + F), pain and focal T2 values, and the number of microfractures and calculated BME for the focal W/(W + F) in the proximal femora. Statistically significant correlations were found between the radiographic findings and MRI values for total W/(W + F), focal W/(W + F) and focal T2 and among the radiographic findings, pain, and hip movement. On histopathology, only a small amount of BME was seen in eight proximal femora. The amount of BME in the OA hip, as measured by MRI, correlates with the severity of pain, radiographic findings, and number of microfractures.

  14. The effects of different nutritional measurements on delayed wound healing after hip fracture in the elderly.

    PubMed

    Guo, Jiong Jiong; Yang, Huilin; Qian, Haixin; Huang, Lixin; Guo, Zhongxing; Tang, Tiansi

    2010-03-01

    It has been well recognized that malnutrition causes wounds to heal inadequately and incompletely. Malnutrition is often observed in the elderly, and it appears to be more severe in patients with hip fracture than in the general aging population. Few prospective studies give a detailed account of the identification and classification of nutritional status in the elderly. The objective of this study was to evaluate the effects of different nutritional measurements on wound healing status after hip fracture in the elderly. From September 2002 to December 2007, 207 hip fracture patients older than 60 y treated surgically were reviewed for preoperative nutritional status. There were 81 males and 126 females with an average age of 75.93 y (62-91 y); 131 cases with femoral neck fractures, 76 cases with intertrochanteric fractures. Parameters indicative of nutritional status (serum albumin, serum transferrin, serum pre-albumin, and total lymphocyte count levels) at the time of admission were assessed, along with anthropometric measurements, Rainey MacDonald nutritional index, and MNA tool. Suture removal was performed on postoperative day 14. Delayed wound healing complicated 46 (22.2%) of the 207 cases. The preoperative serum transferring total lymphocyte count levels, MNA total score, and Rainey MacDonald nutritional index were significantly lower for patients who subsequently had delayed wound healing. When all variables were subjected to multivariate analysis, only total lymphocyte count levels and MNA total score showed significant value in predicting which patients would have delayed wound healing. Through prophylactic antibiotics and adherence to strict aseptic precautions, on follow-up, wound healing was normal in all patients. Patients at risk for delayed wound healing problems after hip fracture can be identified using relatively inexpensive laboratory test such as TLC and MNA tool. The clinician must be aware of the risk values of both measurements. We believe this information is particularly important before planning procedures of hip fractures in the elderly. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  15. Intra-articular steroid injection for osteoarthritis of the hip prior to total hip arthroplasty : is it safe? a systematic review.

    PubMed

    Pereira, L C; Kerr, J; Jolles, B M

    2016-08-01

    Using a systematic review, we investigated whether there is an increased risk of post-operative infection in patients who have received an intra-articular corticosteroid injection to the hip for osteoarthritis prior to total hip arthroplasty (THA). Studies dealing with an intra-articular corticosteroid injection to the hip and infection following subsequent THA were identified from databases for the period between 1990 to 2013. Retrieved articles were independently assessed for their methodological quality. A total of nine studies met the inclusion criteria. Two recommended against a steroid injection prior to THA and seven found no risk with an injection. No prospective controlled trials were identified. Most studies were retrospective. Lack of information about the methodology was a consistent flaw. The literature in this area is scarce and the evidence is weak. Most studies were retrospective, and confounding factors were poorly defined or not addressed. There is thus currently insufficient evidence to conclude that an intra-articular corticosteroid injection administered prior to THA increases the rate of infection. High quality, multicentre randomised trials are needed to address this issue. Cite this article: Bone Joint J 2016;98-B:1027-35. ©2016 The British Editorial Society of Bone & Joint Surgery.

  16. Randomised controlled trial of the sliding hip screw versus X-Bolt Dynamic Hip Plating System for the fixation of trochanteric fractures of the hip in adults: a protocol study for WHiTE 4 (WHiTE4).

    PubMed

    Griffin, Xavier L; Achten, Juul; Sones, William; Cook, Jonathan; Costa, Matthew L

    2018-01-26

    Sliding hip screw fixation is well established in the treatment of trochanteric fractures of the hip. The X-Bolt Dynamic Hip Plating System builds on the successful design features of the sliding hip screw but differs in the nature of the fixation in the femoral head. A randomised pilot study suggested that the X-bolt Dynamic Hip Plating System might provide similar health-related quality of life while reducing the risk of revision surgery when compared with the sliding hip screw. This is the protocol for a multicentre randomised trial of sliding hip screw versus X-Bolt Dynamic Hip Plating System for patients 60 years and over treated for a trochanteric fracture of the hip. Multicentre, multisurgeon, parallel, two-arm, randomised controlled trial. Patients aged 60 years and older with a trochanteric hip fracture are potentially eligible. Participants will be randomly allocated on a 1:1 basis to either sliding hip screw or X-Bolt Dynamic Hip Plating System. Otherwise, all care will be in accordance with National Institute for Health and Care Excellence guidance. A minimum of 1128 patients will be recruited to obtain 90% power to detect a 0.075-point difference in EuroQol-5D health-related quality of life at 4 months postrandomisation. Secondary outcomes include mortality, residential status, revision surgery and radiographic measures. The treatment effect will be estimated using a two-sided t-test adjusted for age, gender and cognitive impairment based on an intention-to-treat analysis. National Research Ethics Committee approved this study on 5 February 2016 (16/WM/0001). The study is sponsored by the University of Oxford and funded through an investigator initiated grant by X-Bolt Orthopaedics. A manuscript for a high-impact peer-reviewed journal will be prepared, and the results will be disseminated to patients through local mechanisms at participating centres. ISRCTN92825709. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Translation, cross-cultural adaptation, and psychometric properties of the German version of the hip disability and osteoarthritis outcome score.

    PubMed

    Blasimann, Angela; Dauphinee, Sharon Wood; Staal, J Bart

    2014-12-01

    Clinical measurement. To translate and cross-culturally adapt the Hip disability and Osteoarthritis Outcome Score (HOOS) from English into German, and to study its psychometric properties in patients after hip surgery. There is no specific hip questionnaire in German that not only measures symptoms and function but also contains items about hip-related quality of life. The translation and cross-cultural adaptation involved forward translation, harmonization, cognitive debriefing, back translation, and comparison to the original HOOS following international guidelines. The German version was tested in 51 Swiss inpatients 8 weeks after different types of hip surgery, mainly total hip replacement. The mean age of the participants was 62.5 years, and the age range was from 27 to 87 years. Thirty (58.8%) of the participants were women. Internal consistency and test-retest reliability were estimated using Cronbach alpha and intraclass correlation coefficients for agreement. For construct validity, total scores of the German HOOS were correlated with those of the Western Ontario and McMaster Universities Osteoarthritis Index. The HOOS was also compared to the Medical Outcomes Study 36-Item Short-Form Health Survey. Cronbach alpha values for all German HOOS subscales were between .87 and .93. For test-retest reliability, the intraclass correlation coefficient for agreement was 0.85 for the total scores of the German HOOS. The Spearman rho for the Medical Outcomes Study 36-Item Short-Form Health Survey physical functioning subscale compared to the sum of all HOOS subscales was 0.71, and that for the Medical Outcomes Study 36-Item Short-Form Health Survey physical component summary was 0.97. The German HOOS has demonstrated adequate reliability and validity. Use of the German HOOS is recommended for assessment of patients after hip surgery, with the proviso that additional psychometric testing should be done in future research.

  18. How much arthritis is too much for hip arthroscopy: a systematic review.

    PubMed

    Domb, Benjamin G; Gui, Chengcheng; Lodhia, Parth

    2015-03-01

    The purpose of this study was to determine the extent of preoperative osteoarthritis (OA) that precludes benefit from hip arthroscopy by systematically reviewing the literature on hip arthroscopy in the setting of OA. We searched the Medline and PubMed databases using the following Medical Subject Heading terms: arthritis, osteoarthritis, chondral damage, chondral injury, chondral delamination, and hip arthroscopy. Two authors independently reviewed the literature and included articles if they were in the English language; commented on preoperative factors, parameters, physical examination, or diagnostic testing that may be evidence of cartilage damage and/or arthritis; contained outcome data on patients undergoing hip arthroscopy; and had a sample size of at least 10 patients with arthritic changes in the hip. We excluded review articles, technique articles, articles with overlapping patient populations, articles with hip arthroscopy used as an adjunct to an open procedure, articles with inflammatory and septic arthritis, and articles with a mean age younger than 18 years. Our search identified 518 articles, of which 15 met the inclusion and exclusion criteria. Two thousand fifty-one hips underwent arthroscopy at a mean patient age of 40.2 years. Of these, 1,195 hips had signs of OA. There were 345 conversions to total hip arthroplasty/surface replacement arthroplasty. Of these patients, 274 had OA. Eight patient-reported outcome instruments were used. Factors influencing outcomes were preoperative OA, age, chondral damage, femoroacetabular impingement, and duration of symptoms. Current evidence is insufficient to define a cutoff for how much arthritis is too much for hip arthroscopy. However, this analysis shows that patients with a Tönnis grade of 1 or greater or a joint space of 2 mm or less are less likely to benefit from hip arthroscopy and more likely to require conversion to total hip arthroplasty/surface replacement arthroplasty. Postoperative scores on patient-reported outcome instruments are lower in the arthritic population at follow-up compared with their nonarthritic counterparts. Level IV, systematic review of Level III and IV studies. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  19. [Short-term curative effects of Tantalum rod treatment in early avascular necrosis].

    PubMed

    Ye, Fu-Sheng; Ni, Zhe-Ji; Chu, Xiao-Bing; He, Bang-Jian; Li, Ju; Tong, Pei-Jian

    2013-08-01

    To explore the recent clinical curative effect of Tantalum rod in treating the early avascular necrosis. From January 2008 to November 2008, the 25 patients (39 hips) with early avascular necrosis accepted tantalum rod placement and included 9 males (11 hips) and 16 females (28 hips) with an average age of 37 years old ranging from 18 to 74 years old. Four patients (6 hips) caused by Alcoholic, 6 patients (8 hips) by hormone, 2 cases (2 hips) by traumatic, 13 cases (23 hips) by idiopathic. Steinberg preoperative stage involved 7 hips in period I, 24 hips in period II, 8 hips in period III. Curative effect analysis included preoperative and postoperative Harris score, radiographic changes and hip replacement for follow-up to accept the end of the femoral head survival rate. All patients were followed up for 6 to 47 months (averaged 37.4 months). All 12 hips imaging appeard progress,including tantalum rod exit in 1 hip, hip hemiarthroplasty collapse in 3 hips, the area increased to avascular necrosis in 8 hips. Six hips accepted total hip replacement, including imaging progress in 5 hips (41.7%, 5/12), no imaging progress in 1 hip (3.7%,1/27). All hips' Kaplan-Meier survival curves showed 6-month survival rate was (97.4 +/- 2.5)% after tantalum stick insertion, 1-year survival rate was (94.7 +/- 3.6), and 2-year survival rate was (88.6 +/- 5.4)%, 3-year survival rate was (72.5 +/- 11.2). It is effective for treatment of avascular necrosis of femoral head in Steinberg I and II by Tantalum rod, and it can effectively relieve femoral head replacement time.

  20. Etidronate

    MedlinePlus

    ... the skeleton) in people who have had total hip replacement surgery (surgery to replace the hip joint with an artificial joint) or in people ... 8 ounces [180 to 240 mL]) of plain water while you are sitting or standing. Sit or ...

  1. Hip fracture prevalence in grandfathers is associated with reduced cortical cross-sectional bone area in their young adult grandsons.

    PubMed

    Rudäng, Robert; Ohlsson, Claes; Odén, Anders; Johansson, Helena; Mellström, Dan; Lorentzon, Mattias

    2010-03-01

    Parent hip fracture prevalence is a known risk factor for osteoporosis. The role of hip fracture prevalence in grandparents on areal bone mineral density (aBMD) and bone size in their grandsons remains unknown. The objective of the study was to examine whether hip fracture prevalence in grandparents was associated with lower aBMD and reduced cortical bone size in their grandsons. This was a population-based cohort study in Sweden. Subjects included 1015 grandsons (18.9 +/- 0.6) (mean +/- sd) and 3688 grandparents. aBMD, cortical bone size, volumetric bone mineral density and polar strength strain index of the cortex in the grandsons in relation to hip fracture prevalence in their grandparents were measured. Grandsons of grandparents with hip fracture (n = 269) had lower aBMD at the total body, radius, and lumbar spine, but not at the hip, as well as reduced cortical cross-sectional area at the radius (P < 0.05) than grandsons of grandparents without hip fracture. Subgroup analysis demonstrated that grandsons of grandfathers with hip fracture (n = 99) had substantially lower aBMD at the lumbar spine (4.9%, P < 0.001) and total femur (4.1%, P = 0.003) and lower cortical cross-sectional area of the radius (4.1%, P < 0.001) and tibia (3.3%, P < 0.011). Adjusting bone variables for grandson age, weight, height, smoking, calcium intake, and physical activity and taking grandparent age at register entry, years in register, and grandparent sex into account strengthened or did not affect these associations. Family history of a grandfather with hip fracture was associated with reduced aBMD and cortical bone size in 19-yr-old men, indicating that patient history of hip fracture in a grandfather could be of value when evaluating the risk of low bone mass in men.

  2. HIP AND GLENOHUMERAL PASSIVE RANGE OF MOTION IN COLLEGIATE SOFTBALL PLAYERS

    PubMed Central

    Plummer, Hillary; Brambeck, Allison

    2016-01-01

    Background and Purpose Range of motion deficits at the hip and glenohumeral joint (GHJ) may contribute to the incidence of injury in softball players. With injury in softball players on the rise, softball related studies in the literature are important. The purpose of this study was to examine hip and GHJ passive range of motion (PROM) patterns in collegiate softball players. Hypothesis It was hypothesized that the position players would exhibit significantly different PROM patterns than pitchers. Additionally, position players would exhibit significantly different side-to-side differences in PROM for both the hip and GHJ compared to pitchers. Study Design Prospective cohort study. Methods Forty-nine collegiate softball players (19.63 ± 1.15 years; 170.88 ± 8.08 cm; 72.96 ± 19.41 kg) participated. Passive hip and GHJ internal (IR) and external rotation (ER) measures were assessed. Glenohumeral PROM was measured with the participants supine with the arm abducted to 90 °. The measurements were recorded when the scapula began to move or a firm capsular end-feel was achieved. The hip was positioned in 90 ° of flexion and passively rotated until a capsular end-feel was achieved. Total PROM was calculated by taking the sum of IR and ER for both the hip and GHJ. Results No significant side-to-side PROM differences were observed in pitchers, at the GHJ or hip joint. Position players throwing side hip IR was significantly greater than the non-throwing side hip (p = 0.002). The non-throwing side hip had significantly greater ER compared to the throwing side hip (p = 0.002). When examining side-to-side differences at the GHJ, IR was significantly greater in the non-throwing shoulder (p = 0.047). No significant differences in total range of motion of the hip and GHJ were observed. Conclusion In the current study, position players displayed side-to-side differences in hip and GHJ IR PROM while no statistically significant differences were observed in the softball pitchers. The findings of the current study add to the body of literature related to PROM in throwing athletes, additionally these are the first hip IR and ER PROM data presented in softball players. Level of Evidence Level 3 PMID:27757286

  3. Anticipatory postural adjustments during lateral step motion in patients with hip osteoarthritis.

    PubMed

    Tateuchi, Hiroshige; Ichihashi, Noriaki; Shinya, Masahiro; Oda, Shingo

    2011-02-01

    Patients with hip osteoarthritis (OA) have difficulty with mediolateral postural control. Since the symptom of hip OA includes joint pain, which mostly occurs upon initial movement, patients with hip OA might have disabling problems with movement initiation. This study aimed to identify the movement strategy during the anticipatory postural adjustments in the lateral step motion in patients with hip OA. We studied 18 female subjects with unilateral hip OA and 10 healthy subjects, and measured temporal, kinetic, and kinematic variables. Patients with hip OA required a longer duration of anticipation phase than the control subjects, the total duration of lateral stepping was not different between the groups. Displacement of the center of mass to the supporting (affected) side during the anticipation phase was not different between the two groups. These findings suggest that, in patients with hip OA, the center of mass slowly moved to the affected side. Furthermore, patients with hip OA showed greater shift of the trunk to the supporting side than did the control subjects. These movement characteristics might contribute to the achievement of both protection of the affected hip joint and quickness in the subsequent lateral step in patients with hip OA.

  4. Bone Remodeling in Acetabular Reconstruction Using a Kerboull-Type Reinforcement Device and Structural Bone-Grafting in Total Hip Arthroplasty.

    PubMed

    Oe, Kenichi; Iida, Hirokazu; Tsuda, Kohei; Nakamura, Tomohisa; Okamoto, Naofumi; Ueda, Yusuke

    2017-03-01

    The purpose of this study was to identify the long-term durability of the Kerboull-type reinforcement device (KT plate) in acetabular reconstruction for massive bone defects, assessing the remodeling of structural bone grafts. This study retrospectively evaluated 106 hips that underwent acetabular reconstruction using a KT plate between November 2000 and December 2010. Thirty-eight primary total hip arthoplasties (THAs) and 68 revised THAs were performed, and the mean duration of clinical follow-up was 8 years (5-14 years). Regarding reconstructing the acetabular bone defects, autografts were used in 37 hips, allografts in 68 hips, and A-W glass ceramics in 2 hips. One hip exhibited radiological migration and no revision for aseptic loosening. The mean Merle d'Aubigné Clinical Score improved from 7.5 points (4-12 points) preoperatively to 10.9 points (9-18 points) at the last follow-up. The Kaplan-Meier survival rate for radiological migration of primary and revised THAs at 10 years was 100% and 97% (95% confidence interval: 96%-100%), respectively. Bone remodeling was evaluated using the radiological demarcation at the bone-to-bone interface, and an improvement of 100% in primary THAs and 94% in revised THAs was observed. For massive bone defects, acetabular reconstruction using the KT plate with a structural bone grafting can yield successful results. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Cross-cultural adaptation and validation of the Turkish version of Oxford hip score.

    PubMed

    Tuğay, Baki Umut; Tuğay, Nazan; Güney, Hande; Hazar, Zeynep; Yüksel, İnci; Atilla, Bülent

    2015-06-01

    The purpose of this study was to translate the Oxford hip score (OHS) into Turkish and to evaluate the psychometric properties by testing the internal consistency, reproducibility, construct validity, and responsiveness in patients with hip osteoarthritis (OA). Oxford hip score was translated and culturally adapted according to the guidelines in the literature. Seventy patients (mean age 61.45 ± 9.29 years) with hip osteoarthritis participated in the study. Patients completed the Turkish Oxford hip score (OHS-TR), the Short-Form 36 (SF-36), and Western Ontario and McMaster Universities Index (WOMAC). Internal consistency was tested using Cronbach's α coefficient. Patients completed OHS-TR questionnaire twice in 7 days for determining the reproducibility. Correlation between the total results of both tests was determined by the Pearson correlation coefficient and intraclass correlation coefficient (ICC). Validity was assessed by calculating the Pearson correlation coefficient between the OHS-TR and WOMAC and SF-36 scores. Floor and ceiling effects were analyzed. The internal consistency was high (Cronbach's α 0.93). The construct validity showed a significant correlation between the OHS-TR and WOMAC and related SF-36 domains (p < 0.001). The ICC's ranged between 0.80 and 0.99. There was no floor or ceiling effect in total OHS-TR score. The OHS-TR questionnaire is valid, reliable, and responsive for the Turkish-speaking patients with hip OA.

  6. Prevalence and severity of hip and groin pain in sub-elite male football: a cross-sectional cohort study of 695 players.

    PubMed

    Thorborg, K; Rathleff, M S; Petersen, P; Branci, S; Hölmich, P

    2017-01-01

    The purpose of this study was twofold: (a) to investigate the prevalence of hip and groin pain in sub-elite male adult football in Denmark and (b) to explore the association between prevalence and duration of hip and groin pain in the previous season with the Copenhagen Hip and Groin Outcome Score (HAGOS) in the beginning of the new season. In total 695 respondents from 40 teams (Division 1-4) were included. Players completed in the beginning of the new season (July-Sept 2011) a self-reported paper questionnaire on hip and/or groin pain during the previous season and HAGOS. In total 49% (95% CI: 45-52%) reported hip and/or groin pain during the previous season. Of these, 31% (95% CI: 26-36%) reported pain for >6 weeks. Players with the longest duration of pain during the previous season had the lowest HAGOS scores, when assessed at the beginning of the new season, P < 0.001. This study documents that half of sub-elite male adult football players report pain in the hip and/or groin during a football season. The football players with the longest duration of pain in previous season displayed the lowest HAGOS scores in the beginning of the new season. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Analysis of the kinematics of different hip simulators used to study wear of candidate materials for the articulation of total hip arthroplasties.

    PubMed

    Ramamurti, B S; Estok, D M; Jasty, M; Harris, W H

    1998-05-01

    We developed an analytical technique to determine the paths traced by specific points on the femoral head against the acetabulum in the human hip joint during gait. The purpose of the study was to apply this technique to the mechanical hip simulators chosen to conduct wear tests on polymeric acetabular liners used in total hip replacements. These simulators differ from one another in the type of motion produced, apart from other variables such as type of lubricant and head position. Due to the variation in the kinematics between the machines, the paths traced by the points on the femoral head against the acetabular liner ranged from simple linear traces to figure-8 loops and quasi-elliptical paths during a single simulator cycle. The distances traveled by these points during the same period also varied appreciably among the different hip simulator designs. These results are important when combined with other studies that have shown that kinematics can play an important role in the outcome of in vitro wear experiments. The kinematic differences quantified in this study can partially explain the substantial differences in wear data reported from different simulator designs and also underscore the usefulness of the technique described in this study in judging the results from different hip simulator experiments.

  8. Assessment of reliability, validity, responsiveness and minimally important change of the German Hip dysfunction and osteoarthritis outcome score (HOOS) in patients with osteoarthritis of the hip.

    PubMed

    Arbab, Dariusch; van Ochten, Johannes H M; Schnurr, Christoph; Bouillon, Bertil; König, Dietmar

    2017-12-01

    Patient-reported outcome measures are a critical tool in evaluating the efficacy of orthopedic procedures. The intention of this study was to evaluate reliability, validity, responsiveness and minimally important change of the German version of the Hip dysfunction and osteoarthritis outcome score (HOOS). The German HOOS was investigated in 251 consecutive patients before and 6 months after total hip arthroplasty. All patients completed HOOS, Oxford-Hip Score, Short-Form (SF-36) and numeric scales for pain and disability. Test-retest reliability, internal consistency, floor and ceiling effects, construct validity and minimal important change were analyzed. The German HOOS demonstrated excellent test-retest reliability with intraclass correlation coefficient values > 0.7. Cronbach´s alpha values demonstrated strong internal consistency. As hypothesized, HOOS subscales strongly correlated with corresponding OHS and SF-36 domains. All subscales showed excellent (effect size/standardized response means > 0.8) responsiveness between preoperative assessment and postoperative follow-up. The HOOS and all subdomains showed higher changes than the minimal detectable change which indicates true changes. The German version of the HOOS demonstrated good psychometric properties. It proved to be valid, reliable and responsive to the changes instrument for use in patients with hip osteoarthritis undergoing total hip replacement.

  9. Three-Dimensional Analysis of the Contact Pattern between the Cortical Bone and Femoral Prosthesis after Cementless Total Hip Arthroplasty

    PubMed Central

    Mishima, Hajime; Sugaya, Hisashi; Nishino, Tomofumi; Yamazaki, Masashi

    2016-01-01

    The cementless stem Excia (B. Braun, Melsungen, Germany) implant has a rectangular cross-sectional shape with back-and-forth flanges and a plasma-sprayed, dicalcium phosphate dihydrate coating from the middle to proximal portion to increase initial fixation and early bone formation. Here, the conformity of the Excia stem to the femoral canal morphology was three-dimensionally assessed using computed tomography. Forty-three patients (45 hips) were examined after primary total hip arthroplasty with a mean follow-up of 27 ± 3 months (range: 24–36 months). Spot welds occurred at zone 2 in 16 hips and at zone 6 in 24 hips, with 83% (20/24 hips) of those occurring within 3 months after surgery. First- (n = 12 hips), second- (n = 32), and third- (n = 1) degree stress shielding were observed. The stem was typically in contact with the cortical bone in the anterolateral mid-portion (100%) and posteromedial distal portions (85%). Stress shielding did not progress, even in cases where the stems were in contact with the distal portions. The anterior flange was in contact with the bone in all cases. The stability of the mid-lateral portion with the dicalcium phosphate dihydrate coating and the anterior flange may have inhibited the progression of stress shielding beyond the second degree. PMID:26881087

  10. Adventure sports and sexual freedom hip replacement: the tripolar hip.

    PubMed

    Pritchett, James W

    2018-01-01

    Certain athletic activities and lifestyles require a completely stable and very mobile hip. Total hip replacement with a natural femoral head size and two mobile-bearing surfaces (i.e., a "tripolar" prosthesis) is the most stable prosthesis. Elegant design and wear-resistant bearing surfaces are the keys to long-term implant survivorship. The hypothesis is that a ceramic-coated tripolar prosthesis using highly cross-linked polyethylene can provide full function and complete stability with low wear. This study sought to determine: (1) patient-reported outcomes, (2) functional outcomes, (3) implant survivorship and complications, and (4) postoperative sexual limitations. Between 1998 and 2011, the author performed 160 primary total hip replacements using tripolar prostheses in patients participating in adventure sports and other physically demanding activities. The institutional review board approved this study. The inclusion criteria were patients who needed unrestricted activity and who were not candidates for or did not choose hip resurfacing. Patients were followed every second year and assessed with radiographs, Harris Hip Score, WOMAC, SF-12, and UCLA functional outcome scores. Patients were asked about symptoms of instability and satisfaction with their hip replacement. Patients were asked both preoperatively and 2 years postoperatively four questions about their sexual activity. Mean follow-up was 11 years. At 2 years' postoperatively, 98% of patients reported their satisfaction as excellent or good and 99% were not limited for sexual activity following surgery. Seventy-four percent of patients reported they were recovered within 6 weeks of surgery. There were no dislocations. There were three revision procedures for implant loosening, infection, and periprosthetic fracture, but there were no failures of the tripolar articulation. The mean postoperative UCLA score was the highly athletic score of 8. There were no signs of osteolysis, wear, or metal sensitivity reactions. The range of motion achieved, sexual, and functional outcomes were higher than with other types of total hip replacement. This ceramic-coated tripolar prosthesis using highly cross-linked polyethylene provides full function, complete stability, and low wear to younger, active patients, thus confirming the hypothesis and clinical relevance.

  11. Retrospective Analysis for Genetic Improvement of Hip Joints of Cohort Labrador Retrievers in the United States: 1970–2007

    PubMed Central

    Lust, George; Zhu, Lan; Zhang, Zhiwu; Todhunter, Rory J.

    2010-01-01

    Background Canine Hip Dysplasia (CHD) is a common inherited disease that affects dog wellbeing and causes a heavy financial and emotional burden to dog owners and breeders due to secondary hip osteoarthritis. The Orthopedic Foundation for Animals (OFA) initiated a program in the 1960's to radiograph hip and elbow joints and release the OFA scores to the public for breeding dogs against CHD. Over last four decades, more than one million radiographic scores have been released. Methodology/Principal Findings The pedigrees in the OFA database consisted of 258,851 Labrador retrievers, the major breed scored by the OFA (25% of total records). Of these, 154,352 dogs had an OFA hip score reported between 1970 and 2007. The rest of the dogs (104,499) were the ancestors of the 154,352 dogs to link the pedigree relationships. The OFA hip score is based on a 7-point scale with the best ranked as 1 (excellent) and the worst hip dysplasia as 7. A mixed linear model was used to estimate the effects of age, sex, and test year period and to predict the breeding value for each dog. Additive genetic and residual variances were estimated using the average information restricted maximum likelihood procedure. The analysis also provided an inbreeding coefficient for each dog. The hip scores averaged 1.93 (±SD = 0.59) and the heritability was 0.21. A steady genetic improvement has accrued over the four decades. The breeding values decreased (improved) linearly. By the end of 2005, the total genetic improvement was 0.1 units, which is equivalent to 17% of the total phenotypic standard deviation. Conclusion/Significance A steady genetic improvement has been achieved through the selection based on the raw phenotype released by the OFA. As the heritability of the hip score was on the low end (0.21) of reported ranges, we propose that selection based on breeding values will result in more rapid genetic improvement than breeding based on phenotypic selection alone. PMID:20195372

  12. Hip fusion takedown to a total hip arthroplasty-is it worth it? A systematic review.

    PubMed

    Jauregui, Julio J; Kim, Joseph K; Shield, William P; Harb, Matthew; Illical, Emmanuel M; Adib, Farshad; Maheshwari, Aditya V

    2017-08-01

    Patients with surgically or spontaneously fused hips are often dissatisfied with their overall function and the debilitating effect on adjacent joints. Therefore, in properly selected patients, hip fusion-takedown and conversion to total hip arthroplasty (THA) can result in improved function and decreased pain. We aimed to (1) evaluate the indications for conversion, (2) evaluate the clinical outcomes, (3) analyze the overall complications, and (4) identify the overall satisfaction following the procedure. A systematic and comprehensive literature search was performed to analyze studies evaluating conversion of hip fusion to THA. After reviewing 3,882 studies, 27 total studies (1,104 hips) met our inclusion/exclusion criteria and were included in our final analysis. A weighted mean of rates was determined for each complication, including infection, instability, loosening, nerve-related, abductor-related, venous thrombotic event, and revision. The study population consisted of 53.2% male and 46.8% female subjects. The mean age at time of conversion was 52 years (range 36-65 years), the mean time until follow-up was 9.2 years (range 2.5-17.3), and the mean duration of arthrodesis was 27.7 years (range 11-40.2). As measured by Harris Hip Score, overall clinical outcomes improved from 58.1 points (range 42.4-70 points) pre-operatively to 80.0 (range 62-93.5) post-operatively. The specific complication rates were 5.3% (range 0-43.6%) for infection, 2.6% (range 0-15.4%) for instability, 6.2% (range 0-17.2%) for loosening, 4.7% (range 0-13%) for nerve-related complications, 13.1% (range 0-87%) for abductor-related complications, and 1.2% (range 0-13%) for venous thrombotic events. The revision rate was 12.0% (range 0-43.6%). Takedown of a fused-hip can be a challenging procedure. Although patients can benefit functionally, both patients and surgeons need to be aware of the complications and increased risk of further revision procedures, which should be an important part of the pre-operative discussion.

  13. The association between pre-operative sepsis and 30-day mortality in hip fracture patients-A cohort study.

    PubMed

    Mørch, S S; Tantholdt-Hansen, S; Pedersen, N E; Duus, C L; Petersen, J A; Andersen, C Ø; Jarløv, J O; Meyhoff, C S

    2018-05-24

    Post-operative sepsis considerably increases mortality, but the extent of pre-operative sepsis in hip fracture patients and its consequences are sparsely elucidated. The aim of this study was to assess the association between pre-operative sepsis and 30-day mortality after hip fracture surgery. We conducted a retrospective analysis of data collected among 1894 patients who underwent hip fracture surgery in the Capital Region of Denmark in 2014 (NCT03201679). Data on vital signs, cultures and laboratory data were obtained. Sepsis was defined as a positive culture of any kind and presence of systemic inflammatory response syndrome within 24 hours and was assessed within 72 hours before surgery and 30 days post-operatively. Primary outcome was 30-day mortality. Secondary outcomes included length of hospital stay and admission to intensive care unit. A total of 144 (7.6%) of the hip fracture patients met the criteria for pre-operative sepsis. The 30-day mortality was 13.9% in patients with pre-operative sepsis as compared to 9.0% in those without (OR 1.69, 95% CI [1.00; 2.85], P = .08). Patients with pre-operative sepsis had longer hospital stays (median 10 days vs 9 days, mean difference 2.1 [SD 9.4] days, P = .03), and higher frequency of ICU admission (11.1% vs 2.7%, OR 4.15, 95% CI [2.19; 7.87], P < .0001). Pre-operative sepsis in hip fracture patients was associated with an increased length of hospital stay and tended to increase mortality. Pre-operative sepsis in hip fracture patients merits more intensive surveillance and increased attention to timely treatment. © 2018 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  14. More than 95% completeness of reported procedures in the population-based Dutch Arthroplasty Register

    PubMed Central

    van Steenbergen, Liza N; Spooren, Anneke; van Rooden, Stephanie M; van Oosterhout, Frank J; Morrenhof, Jan W; Nelissen, Rob G H H

    2015-01-01

    Background and purpose A complete and correct national arthroplasty register is indispensable for the quality of arthroplasty outcome studies. We evaluated the coverage, completeness, and validity of the Dutch Arthroplasty Register (LROI) for hip and knee arthroplasty. Patients and methods The LROI is a nationwide population-based registry with information on joint arthroplasties in the Netherlands. Completeness of entered procedures was validated in 2 ways: (1) by comparison with the number of reimbursements for arthroplasty surgeries (Vektis database), and (2) by comparison with data from hospital information systems (HISs). The validity was examined by conducting checks on missing or incorrectly coded values in the LROI. Results The LROI contains over 300,000 hip and knee arthroplasties performed since 2007. Coverage of all Dutch hospitals (n = 100) was reached in 2012. Completeness of registered procedures was 98% for hip arthroplasty and 96% for knee arthroplasty in 2012, based on Vektis data. Based on comparison with data from the HIS, completeness of registered procedures was 97% for primary total hip arthroplasty and 96% for primary knee arthroplasty in 2013. Completeness of revision arthroplasty was 88% for hips and 90% for knees in 2013. The proportion of missing or incorrectly coded values of variables was generally less than 0.5%, except for encrypted personal identity numbers (17% of which were missing) and ASA scores (10% of which were missing). Interpretation The LROI now contains over 300,000 hip and knee arthroplasty procedures, with coverage of all hospitals. It has a good level of completeness (i.e. more than 95% for primary hip and knee arthroplasty procedures in 2012 and 2013) and the database has high validity. PMID:25758646

  15. Periprosthetic Infection following Primary Hip and Knee Arthroplasty: The Impact of Limiting the Postoperative Surveillance Period.

    PubMed

    Roth, Virginia R; Mitchell, Robyn; Vachon, Julie; Alexandre, Stéphanie; Amaratunga, Kanchana; Smith, Stephanie; Vearncombe, Mary; Davis, Ian; Mertz, Dominik; Henderson, Elizabeth; John, Michael; Johnston, Lynn; Lemieux, Camille; Pelude, Linda; Gravel, Denise

    2017-02-01

    BACKGROUND Hip and knee arthroplasty infections are associated with considerable healthcare costs. The merits of reducing the postoperative surveillance period from 1 year to 90 days have been debated. OBJECTIVES To report the first pan-Canadian hip and knee periprosthetic joint infection (PJI) rates and to describe the implications of a shorter (90-day) postoperative surveillance period. METHODS Prospective surveillance for infection following hip and knee arthroplasty was conducted by hospitals participating in the Canadian Nosocomial Infection Surveillance Program (CNISP) using standard surveillance definitions. RESULTS Overall hip and knee PJI rates were 1.64 and 1.52 per 100 procedures, respectively. Deep incisional and organ-space hip and knee PJI rates were 0.96 and 0.71, respectively. In total, 93% of hip PJIs and 92% of knee PJIs were identified within 90 days, with a median time to detection of 21 days. However, 11%-16% of deep incisional and organ-space infections were not detected within 90 days. This rate was reduced to 3%-4% at 180 days post procedure. Anaerobic and polymicrobial infections had the shortest median time from procedure to detection (17 and 18 days, respectively) compared with infections due to other microorganisms, including Staphylococcus aureus. CONCLUSIONS PJI rates were similar to those reported elsewhere, although differences in national surveillance systems limit direct comparisons. Our results suggest that a postoperative surveillance period of 90 days will detect the majority of PJIs; however, up to 16% of deep incisional and organ-space infections may be missed. Extending the surveillance period to 180 days could allow for a better estimate of disease burden. Infect Control Hosp Epidemiol 2017;38:147-153.

  16. Sagittal plane gait characteristics in hip osteoarthritis patients with mild to moderate symptoms compared to healthy controls: a cross-sectional study.

    PubMed

    Eitzen, Ingrid; Fernandes, Linda; Nordsletten, Lars; Risberg, May Arna

    2012-12-20

    Existent biomechanical studies on hip osteoarthritic gait have primarily focused on the end stage of disease. Consequently, there is no clear consensus on which specific gait parameters are of most relevance for hip osteoarthritis patients with mild to moderate symptoms. The purpose of this study was to explore sagittal plane gait characteristics during the stance phase of gait in hip osteoarthritis patients not eligible for hip replacement surgery. First, compared to healthy controls, and second, when categorized into two subgroups of radiographic severity defined from a minimal joint space of ≤/>2 mm. Sagittal plane kinematics and kinetics of the hip, knee and ankle joint were calculated for total joint excursion throughout the stance phase, as well as from the specific events initial contact, midstance, peak hip extension and toe-off following 3D gait analysis. In addition, the Western Ontario and McMaster Universities Osteoarthritis Index, passive hip range of motion, and isokinetic muscle strength of hip and knee flexion and extension were included as secondary outcomes. Data were checked for normality and differences evaluated with the independent Student's t-test, Welch's t-test and the independent Mann-Whitney U-test. A binary logistic regression model was used in order to control for velocity in key variables. Fourty-eight hip osteoarthritis patients and 22 controls were included in the final material. The patients walked significantly slower than the controls (p=0.002), revealed significantly reduced joint excursions of the hip (p<0.001) and knee (p=0.011), and a reduced hip flexion moment at midstance and peak hip extension (p<0.001). Differences were primarily manifested during the latter 50% of stance, and were persistent when controlling for velocity. Subgroup analyses of patients with minimal joint space ≤/>2 mm suggested that the observed deviations were more pronounced in patients with greater radiographic severity. The biomechanical differences were, however, not reflected in self-reported symptoms or function. Reduced gait velocity, reduced sagittal plane joint excursion, and a reduced hip flexion moment in the late stance phase of gait were found to be evident already in hip osteoarthritis patients with mild to moderate symptoms, not eligible for total hip replacement. Consequently, these variables should be considered as key features in studies regarding hip osteoarthritic gait at all stages of disease. Subgroup analyses of patients with different levels of radiographic OA further generated the hypothesis that the observed characteristics were more pronounced in patients with a minimal joint space ≤2 mm.

  17. Histopathology of femoral head donations: a retrospective review of 6161 cases.

    PubMed

    Mackie, Katherine E; Zhou, Ziqiang; Robbins, Peter; Bulsara, Max; Zheng, Ming H

    2011-08-17

    Although total hip arthroplasty is one of the most common orthopaedic surgical procedures, it remains unclear whether histopathological examination of the excised femoral head adds to the quality of patient care. We propose that assessment of femoral heads resected during total hip arthroplasty and donated for allograft use may provide a profile of femoral head pathology that benefits total hip arthroplasty patients and bone donors. We retrospectively analyzed the histological findings reported for 6161 femoral heads donated for allograft use between 1993 and 2006. Specimens obtained during total hip arthroplasty and specimens donated at death were reviewed. Follow-up investigations that resulted from abnormal histopathological findings were also reviewed. The Western Australian Cancer Registry was used to determine whether patients with a suspected neoplasm were subsequently diagnosed with such a disease. A retrospective review of the histopathological findings was conducted to evaluate and reclassify all previous observations of abnormalities. One hundred and five femoral heads demonstrated abnormal or reactive histopathological features not reported prior to surgery and were rejected for allograft use. A reactive lymphocytic infiltrate, most likely due to osteoarthritis, was the most commonly identified feature (forty-five cases). Other features observed in twenty-seven cases were also most likely due to the presence of severe osteoarthritis. Ten femoral heads demonstrated plasmacytosis, which may have been related to osteoarthritis. Two patients were diagnosed with Paget's disease, and two, with rheumatoid arthritis. Nineteen patients had a suspected neoplasm. Of these nineteen, eight cases of non-Hodgkin's lymphoma or chronic lymphocytic leukemia and one case of myelodysplastic syndrome were confirmed on further investigation. One subsequently confirmed malignancy was detected per 770 femoral heads examined. Our findings indicate that, even with a detailed medical history and careful physical examination, clinically important diseases including neoplasms and Paget's disease are observed in patients diagnosed with osteoarthritis prior to total hip arthroplasty. Histological examination plays an integral role in quality assurance in femoral head banking, and it also represents a possible early diagnostic test for bone and bone-marrow-related diseases in patients undergoing total hip arthroplasty.

  18. Cost-Effective Mobile-Based Healthcare System for Managing Total Joint Arthroplasty Follow-Up.

    PubMed

    Bitsaki, Marina; Koutras, George; Heep, Hansjoerg; Koutras, Christos

    2017-01-01

    Long-term follow-up care after total joint arthroplasty is essential to evaluate hip and knee arthroplasty outcomes, to provide information to physicians and improve arthroplasty performance, and to improve patients' health condition. In this paper, we aim to improve the communication between arthroplasty patients and physicians and to reduce the cost of follow-up controls based on mobile application technologies and cloud computing. We propose a mobile-based healthcare system that provides cost-effective follow-up controls for primary arthroplasty patients through questions about symptoms in the replaced joint, questionnaires (WOMAC and SF-36v2) and the radiological examination of knee or hip joint. We also perform a cost analysis for a set of 423 patients that were treated in the University Clinic for Orthopedics in Essen-Werden. The estimation of healthcare costs shows significant cost savings (a reduction of 63.67% for readmission rate 5%) in both the University Clinic for Orthopedics in Essen-Werden and the state of North Rhine-Westphalia when the mobile-based healthcare system is applied. We propose a mHealth system to reduce the cost of follow-up assessments of arthroplasty patients through evaluation of diagnosis, self-monitoring, and regular review of their health status.

  19. Do orthotic walkers affect knee and hip function during gait?

    PubMed

    Richards, Jim; Payne, Katherine; Myatt, Darren; Chohan, Ambreen

    2016-02-01

    Much previous research on orthotic walkers has focussed on their ability to offload structures in the foot and ankle; however, little is known about their effects on lower limb mechanics. This study aimed to determine effects of two orthotic walkers on the biomechanics of the knee and hip joints compared to standardised footwear. A total of 10 healthy participants walked under three conditions: Walker A (Össur, Iceland), Walker B (DJO Global, USA) and standardised footwear (Hotter, UK). Kinematic and kinetic data were collected using a Qualisys motion analysis system (Qualisys Medical AB, Sweden) and force plates (AMTI, Boston, MA, USA). Significant differences were seen in hip kinematics and knee moments between walkers and standardised footwear and in knee kinematics between Walker A and standardised footwear. Both walkers show significant kinematic and kinetic differences compared with standardised footwear; however, Walker A appeared to produce greater deviation, including potentially damaging greater hyperextension moments at the knee. Further research is needed into the effects of orthotic walkers on knee and hip joint mechanics, which should help to inform future designs of walker, with greater focus on obtaining a more normal gait pattern. © The International Society for Prosthetics and Orthotics 2014.

  20. Squat exercise to estimate knee megaprosthesis rehabilitation: a pilot study

    PubMed Central

    Lovecchio, Nicola; Zago, Matteo; Sciumè, Luciana; Lopresti, Maurizio; Sforza, Chiarella

    2015-01-01

    [Purpose] This study evaluated a specific rehabilitation protocol using a half squat after total knee reconstruction with distal femur megaprosthesis and tibial allograft-prosthesis composite. [Subject and Methods] Squat execution was recorded by a three-dimensional system before and after a specific rehabilitation program on a 28-year-old patient. Squat duration, body center of mass trajectory, and vertical range of motion were determined. Step width and joint angles and symmetry (hip flexion, extension, and rotation, knee flexion, and ankle dorsal and plantar flexion) were estimated. Knee and hip joint symmetry was computed using a bilateral cyclogram technique. [Results] After rehabilitation, the squat duration was longer (75%), step width was similar, and vertical displacement was higher. Hip flexion increased by over 20%, and ankle dorsiflexion diminished by 14%. The knee had the highest symmetry gain (4.1–3.4%). Angle-angle plot subtended areas decreased from 108° to 40°2 (hip) and from 204° to 85°2 (knee), showing improvement in movement symmetry. [Conclusion] We concluded that the squat is an effective multifactorial exercise to estimate rehabilitation outcomes after megaprosthesis, also considering that compressive and shear forces are minimal up to 60–70° of knee flexion. PMID:26311992

  1. Recognizing anterior metaphyseal femoral bone loss during uncemented total hip arthroplasty: the skylight sign.

    PubMed

    Harwin, Steven F

    2007-03-01

    During preparation for uncemented femoral arthroplasty, a phenomenon has been observed that indicates thinning of anterior metaphyseal bone to a critical level. Light can be seen from within the canal passing through the anterior cortex. This skylight sign alerts the surgeon that a cortical defect or fracture can occur on reaming, broaching, or component insertion. In 420 consecutive arthroplasties, a skylight sign was noted in 97 (23%) hips. In 5 of those hips an oval cortical defect was created and in 3 hips a fracture occurred during broaching or insertion. Loosening developed in 1 hip with fracture. No fractures or defects occurred in hips without a skylight sign. If a skylight sign is present, the femur is at risk and preventive measures should be taken.

  2. Comparing return to sport activities after short metaphyseal femoral arthroplasty with resurfacing and big femoral head arthroplasties.

    PubMed

    Karampinas, Panagiotis K; Papadelis, Eustratios G; Vlamis, John A; Basiliadis, Hlias; Pneumaticos, Spiros G

    2017-07-01

    Young patients feel that maintaining sport activities after total hip arthroplasty constitutes an important part of their quality of life. The majority of hip surgeons allow patients to return to low-impact activities, but significant caution is advised to taking part in high-impact activities. The purpose of this study is to compare and evaluate the post-operative return to daily living habits and sport activities following short-metaphyseal hip and high functional total hip arthroplasties (resurfacing and big femoral head arthroplasties). In a study design, 48 patients (55 hips) were enrolled in three different comparative groups, one with the short-metaphyseal arthroplasties, a second with high functional resurfacing arthroplasties and a third of big femoral head arthroplasties. Each patient experienced a clinical examination and evaluated with Harris Hip Score, WOMAC, Sf-36, UCLA activity score, satisfaction VAS, anteroposterior and lateral X-rays of the hip and were followed in an outpatient setting for 2 years. Statistical analysis revealed no notable differences between the three groups regarding their demographic data however significant differences have been found between preoperative and postoperative clinical scores of each group. Also, we fail to reveal any significant differences when comparing data of all three groups at the final 2 years postoperative control regarding their clinical scores. The overall outcome of all three groups was similar, all the patients were satisfied and returned to previous level of sport activities. Short metaphyseal hip arthroplasties in young patients intending to return to previous and even high impact sport activities, similar to high functional resurfacing, big femoral head arthroplasties. Short stems with hard on hard bearing surfaces might become an alternative to standard stems and hip resurfacing.

  3. A finite element analysis of the vibrational behaviour of the intra-operatively manufactured prosthesis-femur system.

    PubMed

    Pastrav, L C; Devos, J; Van der Perre, G; Jaecques, S V N

    2009-05-01

    In total hip replacement (THR) a good initial stability of the prosthetic stem in the femur, which corresponds to a good overall initial contact, will help assure a good long-term result. During the insertion the implant stability increases and, as a consequence, the resonance frequencies increase, allowing the assessment of the implant fixation by vibration analysis. The influence of changing contact conditions on the resonance frequencies was however not yet quantitatively understood and therefore a finite element analysis (FEA) was set up. Modal analyses on the hip stem-femur system were performed in various contact situations. By modelling the contact changes by means of the contact tolerance options in the finite element software, contact could be varied over the entire hip stem surface or only in specific zones (proximal, central, distal) while keeping other system parameters constant. The results are in agreement with previous observations: contact increase causes positive resonance frequency shifts and the dynamic behaviour is most influenced by contact changes in the proximal zone. Although the finite element analysis did not establish a monotonous relationship between the vibrational mode number and the magnitude of the resonance frequency shift, in general the higher modes are more sensitive to the contact change.

  4. Accuracy of Clinical Techniques for Evaluating Lower Limb Sensorimotor Functions Associated With Increased Fall Risk.

    PubMed

    Donaghy, Alex; DeMott, Trina; Allet, Lara; Kim, Hogene; Ashton-Miller, James; Richardson, James K

    2016-04-01

    In prior work, laboratory-based measures of hip motor function and ankle proprioceptive precision were critical to maintaining unipedal stance and fall/fall-related injury risk. However, the optimal clinical evaluation techniques for predicting these measures are unknown. To evaluate the diagnostic accuracy of common clinical maneuvers in predicting laboratory-based measures of frontal plane hip rate of torque development (Hip(RTD)) and ankle proprioceptive thresholds (AnkPRO) associated with increased fall risk. Prospective, observational study. Biomechanical research laboratory. A total of 41 older subjects (aged 69.1 ± 8.3 years), 25 with varying degrees of diabetic distal symmetric polyneuropathy and 16 without. Clinical hip strength was evaluated by manual muscle testing (MMT) and lateral plank time, defined as the number of seconds that the laterally lying subject could lift the hips from the support surface. Foot/ankle evaluation included Achilles reflex and vibratory, proprioceptive, monofilament, and pinprick sensations at the great toe. Hip(RTD), abduction and adduction, using a custom whole-body dynamometer. AnkPRO determined with subjects standing using a foot cradle system and a staircase series of 100 frontal plane rotational stimuli. Pearson correlation coefficients (r) and receiver operator characteristic (ROC) curves revealed that LPT correlated more strongly with Hip(RTD) (r/P = 0.61/<.001 and 0.67/<.001, for abductor/adductor, respectively) than did hip abductor MMT (r/P = 0.31/.044). Subjects with greater vibratory and proprioceptive sensation, and intact Achilles reflexes, monofilament, and pin sensation had more precise AnkPRO. LPT of <12 seconds yielded a sensitivity/specificity of 91%/80% for identifying Hip(RTD) < 0.25 (body size in Newton-meters), and vibratory perception of <8 seconds yielded a sensitivity/specificity of 94%/80% for the identification of AnkPRO >1.0°. LPT is a more effective measure of Hip(RTD) than MMT. Similarly, clinical vibratory sense and monofilament testing are effective measures of AnkPRO, whereas clinical proprioceptive sense is not. Copyright © 2016 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  5. Autonomy, Choice, Patient-Centered Care, and Hip Protectors: The Experience of Residents and Staff in Long-Term Care

    PubMed Central

    Sims-Gould, Joanie; McKay, Heather A.; Feldman, Fabio; Scott, Victoria; Robinovitch, Stephen N.

    2013-01-01

    The purpose of this study was to examine long-term care (LTC) resident and staff perceptions on the decision to use hip protectors and identify the factors that influence attitudes toward hip protector use. Staff (N = 39) and residents (N = 27) at two residential care facilities in British Columbia, Canada were invited to participate in focus groups on fall prevention and hip protector use. A total of 11 focus groups were conducted. Using framework analysis results show that residents and staff shared concerns on aesthetic and comfort issues with hip protectors. Residents also generally felt they did not need, or want to use, hip protectors. However, they also had desire to be cooperative within the LTC environment. Staff underscored their role in advocating for hip protector use and their desire to protect residents from harm. Practice considerations for facilities wishing to promote hip protectors within a patient centered framework are highlighted. PMID:24652886

  6. Eleven years of experience with metal-on-metal hybrid hip resurfacing: a review of 1000 conserve plus.

    PubMed

    Amstutz, Harlan C; Le Duff, Michel J

    2008-09-01

    Hip resurfacing is currently the fastest growing hip procedure worldwide. We reviewed 1000 hips in 838 patients who received a Conserve Plus (Wright Medical Technology, Inc., Arlington, Tenn) resurfacing at a single institution. The mean age of the patients was 50.0 years with 74.7% male. The hips were resurfaced irrespective of femoral defect size or etiology. The mean follow-up was 5.6 years (range, 1.1-11.0 years). All clinical scores improved significantly (P < .05). There was no acetabular component loosening. Ten were converted to total hip arthroplasty for femoral neck fracture, 20 for femoral loosening, 2 for sepsis, and 1 for recurrent subluxations. The 5-year survivorship was 95.2% with no failures in hips implanted since 2002. Short-term failures can be prevented. First-generation surgical technique and a low body mass index were the most important risk factors for the procedure. Improvements in bone preparation significantly increased prosthetic survival in hips with risk factors for failure.

  7. Hip arthroscopy using the lateral approach.

    PubMed

    Glick, J M

    1988-01-01

    The benefits of hip arthroscopy are apparent. It produces little postoperative morbidity and can be performed on an outpatient basis. The prompt recovery from the operation is also beneficial, particularly for elderly patients. Distraction of the hip by traction on a fracture table is necessary. Suggested indications for this procedure include synovectomy and synovial biopsy; removal of loose bodies; removal of debris after a closed reduction of a fracture-dislocation; evaluation and treatment of osteochondritis dissecans; evaluation for arthroplasty; and unresolved hip pain. Whether the lateral approach is useful in the following situations is yet to be explored: (1) Evaluation of pediatric conditions such as Legg-Perthes disease and congenital dislocated hip; (2) treatment of localized infection; (3) removal of entrapped methylmethacrylate in total hip replacement; and (4) reducing and fixating an acetabular fracture (M. Brennan, oral communication, April 6, 1987). Arthroscopy of the hip joint by the lateral approach is a valuable addition to the evaluation and treatment of hip disorders.

  8. Changes of bone mineral density after cementless total hip arthroplasty with two different stems

    PubMed Central

    Ito, Kouji; Yamamoto, Kengo

    2007-01-01

    Cementless total hip arthroplasty has achieved reliable long-term results since porous coatings were developed, but postoperative changes around the stem remain poorly documented. In this study, changes of the bone mineral density (BMD) were compared between two types of cementless stem. In group B (28 patients with 31 hips), a straight tapered stem with porous plasma spray coating on the proximal 1/4 was used, while group S (24 patients with 26 hips) was given a fluted, tri-slot stem with porous hydroxyapatite coating on the proximal 1/3. In group B, there was an early decrease of BMD, which recovered after 12 months, indicating that stress shielding was minimal. In group S, however, BMD continued to decrease without recovery. The stem shape and radiological findings suggested that the cause of stress shielding in group S was distal fixation. PMID:17225187

  9. The cementless anatomic medullary locking femoral component: an independent clinical and radiographic assessment

    PubMed Central

    Chess, David G.; Grainger, R. Wayne; Phillips, Tom; Zarzour, Zane D.; Sheppard, Bruce R.

    1996-01-01

    Objective To review the clinical performance of the anatomic medullary locking (AML) femoral stem in total hip arthroplasty. Design A clinical and radiographic review. Setting A tertiary lower limb joint replacement centre. Patients Two hundred and twenty-one patients with noninflammatory gonarthrosis. Interventions Two hundred and twenty-seven primary total hip arthroplasties with the noncemented AML component completed by two surgeons. Main Outcome Measures Independent review by two experienced reviewers of the postoperative Harris hip score, radiographs of component fixation, size and degree of diaphyseal fill. Results Harris hip score was 84 (range from 43 to 98); component fixation showed bone ingrowth in 41%, stable fixation with fibrous ingrowth in 56% and unstable fixation in 3%; severe thigh pain in 4% of cases correlated with unstable fixation, and there was mild thigh pain in 20% of cases. Conclusion The AML femoral stem performs well in replacement arthroplasty compared with other noncemented stems. PMID:8857987

  10. Unconstrained tripolar implants for primary total hip arthroplasty in patients at risk for dislocation.

    PubMed

    Guyen, Olivier; Pibarot, Vincent; Vaz, Gualter; Chevillotte, Christophe; Carret, Jean-Paul; Bejui-Hugues, Jacques

    2007-09-01

    We performed a retrospective study on 167 primary total hip arthroplasty (THA) procedures in 163 patients at high risk for instability to assess the reliability of unconstrained tripolar implants (press-fit outer metal shell articulating a bipolar polyethylene component) in preventing dislocations. Eighty-four percent of the patients had at least 2 risk factors for dislocation. The mean follow-up length was 40.2 months. No dislocation was observed. Harris hip scores improved significantly. Six hips were revised, and no aseptic loosening of the cup was observed. The tripolar implant was extremely successful in achieving stability. However, because of the current lack of data documenting polyethylene wear at additional bearing, the routine use of tripolar implants in primary THA is discouraged and should be considered at the present time only for selected patients at high risk for dislocation and with limited activities.

  11. Effect of Body Mass Index on Digital Templating for Total Hip Arthroplasty.

    PubMed

    Sershon, Robert A; Diaz, Alejandro; Bohl, Daniel D; Levine, Brett R

    2017-03-01

    Digital templating is becoming more prevalent in orthopedics. Recent investigations report high accuracy using digital templating in total hip arthroplasty (THA); however, the effect of body mass index (BMI) on templating accuracy is not well described. Digital radiographs of 603 consecutive patients (645 hips) undergoing primary THA by a single surgeon were digitally templated using OrthoView (Jacksonville, FL). A 25-mm metallic sphere was used as a calibration marker. Preoperative digital hip templates were compared with the final implant size. Hips were stratified into groups based on BMI: BMI <30 (315), BMI 30-35 (132), BMI 35-40 (97), and BMI >40 (101). Accuracy between templating and final size did not vary by BMI for acetabular or femoral components. Digital templating was within 2 sizes of the final acetabular and femoral implants in 99.1% and 97.1% of cases, respectively. Digital templating is an effective means of predicting the final size of THA components. BMI does not appear to play a major role in altering THA digital templating accuracy. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Clinical Results of Total Hip Arthroplasty in Two Patients with Charcot Hip Joints due to Congenital Insensivity to Pain with Anhydrosis

    PubMed Central

    Inoue, Daisuke; Kajino, Yoshitomo; Taga, Tadashi; Yamamoto, Takashi; Takagi, Tomoharu

    2018-01-01

    Traditionally, Charcot arthropathy has been considered an absolute contraindication for total hip arthroplasty (THA). However, some recent reports have shown that good short- to mid-term results can be achieved by improving the durability of the implant. This paper reports the mid- to long-term results of THA in two patients with Charcot hip joints caused by congenital insensivity to pain with anhydrosis. Both patients suffered multiple posterior dislocations in the six months immediately following surgery. However, with the continuous use of a hard abduction brace, one patient was eventually able to walk with a lofstrand cane and the other with the use of one crutch. Although one patient experienced a dislocation five years after surgery, X-rays taken after nine years and five years, respectively, revealed no clinical signs of implant loosening. We conclude that, with careful planning and appropriate precautions, THA may be a viable treatment option for Charcot hip joints caused by congenital insensivity to pain with anhydrosis. PMID:29666733

  13. Properties of the patient administered questionnaires: new scales measuring physical and psychological symptoms of hip and knee disorders.

    PubMed

    Mancuso, Carol A; Ranawat, Amar S; Meftah, Morteza; Koob, Trevor W; Ranawat, Chitranjan S

    2012-04-01

    The Patient Administered Questionnaires (PAQ) incorporate physical and psychological symptoms into one scale and permit more comprehensive self-reports for hip and knee disorders. We tested the psychometric properties of the PAQ-Hip and PAQ-Knee. Correlations between baseline PAQ-Hip and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) were .39 to .72 (n = 102), .39 to .69 for score change (n = 68 post-total hip arthroplasty), and most κ values > .60 (n = 50). Correlations between baseline PAQ-Knee and WOMAC were .35 to .64 (n = 100), .62 to .79 for score change (n = 43 post-total knee arthroplasty), and most κ values >.60 (n = 51). For both scales, effect sizes were higher than for the WOMAC, and there was modest correlation between physical and psychological questions, indicating these concepts are not completely interchangeable. Thus, the PAQ scales have strong psychometric properties and are unique compared with existing scales by including physical and psychological symptoms. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. [Total hip arthroplasty in post-dysplastic hip arthritis. Can type and position of the acetabular component influence longevity of the prosthesis?].

    PubMed

    Fousek, J; Indráková, P

    2007-02-01

    The aim of the study was a retrospective evaluation of our patients with post-dysplastic hips treated by cemented or non-cemented total hip arthroplasty (THA) in order to ascertain which type and position of the acetabular component was most effective. In the years 1999-2002, 111 THA procedures were performed in 93 patients, 76 women and 17 men, with post-dysplastic hip arthritis. The average age of the patients at the time of implantation was 52.6 years. On the basis of pre-operative radiographic findings, the patients' conditions were evaluated using the Hartofilakidis classification into three disease categories: dysplasia, low dislocation and high dislocation, and the patients were placed in two groups. Group 1 included 78 patients, and group 2 comprised 26 patients. None of our patients was classified as having high dislocation. Thirty-nine of these patients had previously undergone surgery for dysplastic hips. A total of 104 THAs were evaluated, because radiographic data was incomplete in seven cases. In addition to X-ray findings, the prosthesis type (cemented, hybrid, non-cemented), post-operative complications and signs of loosening were included in the evaluation. Clinical outcomes were assessed by the Harris score. The follow-up terminating on 31st December 2005 was 67 months on the average. In group 1 patients, the average Harris score increased from 38.6 to 80.3 points and in group 2 patients from 35.5 to 84.9 points, mostly with excellent and good results. In 72.1 % of the hips, a press-fit acetabular component was implanted. In 55.8 % of the cases, the acetabular component was implanted off the anatomical center of rotation, into the high hip center, with the range from 9 to 20 mm and an average of 15 mm. The average limb lengthening was 2.5 cm, ranging from 1.0 to 3.5 cm. Our results show that it is more effective to use non-cemented THA for post-dysplastic hips. The implantation of a noncemented acetabular component into the high center provides better covering of the cup with solid bone, without the necessity of cotyloplasty or structural graft use. Also, it does not markedly affect hip function or patients' subjective feelings.

  15. Kinematics and Kinetics of Squat and Deadlift Exercises with Varying Stance Widths

    NASA Technical Reports Server (NTRS)

    DeWitt, John K.; Fincke, Renita S.; Logan, Rachel L.

    2011-01-01

    The primary motion of squat and deadlift exercise involves flexion and extension of the hips, knees, and ankles, but each exercise can be performed with variations in stance width. These variations may result in differing kinematics and ground reaction forces (GRF), which may in turn affect joint loading. PURPOSE: The purpose of this investigation was to compare ankle, knee, and hip kinematics and kinetics of normal squat (NS), wide-stance squat (WS), normal deadlift (ND), and sumo deadlift (SD). We hypothesized that hip joint kinematics and work at each joint would differ between exercise variations. METHODS: Six subjects (3 m/3 f; 70.0 plus or minus 13.7 kg; 168 plus or minus 9.9 cm) performed each lift in normal gravity on the ground-based version of the Advanced Resistive Exercise Device (ARED) used on the International Space Station. The ARED provided resistance with a combination vacuum tube/flywheel mechanism designed to replicate the gravitational and inertial forces of free weights. Subjects completed each lift with their 10-repetition maximum load. Kinematic data were collected at 250 Hz by a 12-camera motion-capture system (Smart-D, BTS Bioengineering, Milan, Italy), and GRF data were collected at 1000 Hz with independent force platforms for each leg (Model 9261, Kistler Instruments AG, Winterhur, Switzerland). All data were captured simultaneously on a single workstation. The right leg of a single lift for each motion was analyzed. Modeling software (OpenSim 2.2.0, Simbios, Palo Alto, CA) determined joint kinematics and net positive and negative work at each lower extremity joint. Total work was found as the sum of work across all joints and was normalized by system mass. Effect sizes and their 95% confidence intervals were computed between conditions. RESULTS: Peak GRF were similar for each lift. There were no differences between conditions in hip flexion range of motion (ROM). For hip adduction ROM, there were no differences between the NS, WS, and SD. However, hip adduction ROM was greater during the NS and SD than during the ND. Hip rotation ROM was greater during the WS than during the NS and SD, and was greater during the SD than during the ND. For knee and ankle flexion ROM, the ND, WS, and SD were not different, but ROM was greater during the NS than the ND and greater during the WS than the SD. Total eccentric work was greater during the WS than the SD. Otherwise, there were no differences in eccentric or concentric work between conditions. CONCLUSIONS: Although squat and deadlift exercises consist of similar motions, there are kinematic differences between them that depend on stance width. Total eccentric and concentric work are similar for different lifts, but differing kinematics may require activation of different musculature for each variation. With respect to each condition, in the ND the ROM of each joint tended to be less, and the WS tended to trade knee motion for hip motion. PRACTICAL APPLICATIONS: Knowledge of differences in kinematics and kinetics between different squat and deadlift variations is important for coaches and rehabilitation personnel to understand when prescribing exercise. Our results suggest that each variation of the squat and deadlift should be considered a separate exercise that may induce different long-term training effects.

  16. Total Hip Prostheses in Standing, Sitting and Squatting Positions: An Overview of Our 8 Years Practice Using the EOS Imaging Technology

    PubMed Central

    Lazennec, Jean-Yves; Rousseau, Marc-Antoine; Brusson, Adrien; Folinais, Dominique; Amel, Maria; Clarke, Ian; Pour, Aidin Eslam

    2015-01-01

    More total hip arthroplasty (THA) is performed worldwide and especially in younger and more active patients compared to earlier decades. One of the focuses of THA research in the future will be on optimizing the radiological follow-up of these patients using 2D and 3D measurements of implants position while reducing the radiation dose delivered. Low-dose EOS® imaging is an innovative slot-scanning radiograph system providing valuable information in patient functional positions (standing, sitting and even squatting positions). EOS has been proven accurate and reliable without significant inconvenience caused by the metallic artifacts of implants. The ability to obtain precise data on implant orientation according to the patient posture opens new perspectives for a comprehensive analysis of the pelvic frontal and sagittal balance and its potential impact on implants function and failures. We report our 8 years experience on our first 300 THA patients using this technology routinely for pre and post op evaluation. Our results will be compared and confronted with the actual literature about this innovative technology. We shall especially emphasize our experience about patients with abnormal posture and the evolution of the subject over time, because the phenomenon of an aging spine is frequently associated with the process of aging hips. PMID:25861404

  17. Posterior hip dislocation in a non-professional football player: a case report and review of the literature.

    PubMed

    Bakalakos, Matthaios; Benetos, Ioannis S; Rozis, Meletios; Vlamis, John; Pneumaticos, Spiros

    2018-06-02

    The majority of injuries during a football game are contusions, sprains and/or strains in the thigh, knee and ankle. Hip dislocations account for 2-5% of total hip dislocations, and they can be posterior or anterior. Major complications of traumatic hip dislocation include avascular necrosis of femoral head, secondary osteoarthritis, sciatic nerve injury and heterotopic ossification. On the occasion of a case of a 33-year-old football player, who suffered a posterior hip dislocation, associated with a posterior wall fracture of the acetabulum, while playing football, we review the literature and analyze the various mechanisms of injury, the possible complications and the management including surgery and rehabilitation.

  18. Broach Handle Design Changes Force Distribution in the Femur During Total Hip Arthroplasty.

    PubMed

    Greenhill, Dustin A; Abbasi, Pooyan; Darvish, Kurosh; Star, Andrew M

    2017-06-01

    Curved broach handles were developed to overcome limited surgical exposures during total hip arthroplasty. Some authors report increased intraoperative fracture rates during limited exposures. This study evaluates mechanical force ratios transmitted to the bone while broaching with curved vs straight handles. An experimental model utilized a 6-axis load cell to measure force distributions produced by 4 different broach handles, each with increasing offset and curvature. Handles were separately impacted and dynamic variables assessed. Handles were then digitized using a high-resolution optical system and a finite element analysis (FEA) was performed to account for trabecular bone and vary the location of mallet impact. Off-axis forces, broaching construct moments, and stress within surrounding bone were computed. Using the experimental model, high-offset handles lost on average 4% more hammering force to the horizontal axis. When the FEA utilized moduli of elasticity to estimate broaching through osteoporotic trabecular bone, horizontally displaced forces (toward cortical bone) were magnified from 4% to a maximum value of 52%. Both the experimental construct and FEA confirmed that larger offset handles increase moment-to-force ratios up to 163%-235%, thus rotating the proximal and distal ends of the broach toward cortical bone. Broach handle design is an important determinant of resultant forces transmitted to the broach (and ultimately the bone) during total hip arthroplasty. Unwanted off-axis forces and enhanced rotational dynamics may play a role in intraoperative fractures during femoral canal preparation. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. [Influence of Comorbidities on Revision Rate within the First Year after Primary Total Hip Arthroplasty].

    PubMed

    Nesslage, Roman; Radtke, Kerstin; Hohloch, Lisa; Flörkemeier, Thilo; Windhagen, Henning; Lewinski, Gabriela von

    2017-04-01

    Background Total hip arthroplasty (THA) is very frequently performed. Despite low complication rates, revisions play an important clinical and economical role. The aim of this study was to identify comorbid diseases of patients undergoing primary THA and their potential influence on the survival of hip replacements. Patients/Material and Methods A total of 867 patients were included in this retrospective study. All revisions were reviewed that took place at our hospital within one year of primary implantation of THA. Comorbid diseases were detected by administrative data, using the Elixhauser definition, which includes thirty diseases. The Cox regression model and Fisher's exact test were used to examine correlations between comorbidities and risk of revision. Results 41 Patients required re-operation within the first year of surgery. The presence of one or more of the analysed comorbidities was associated with a greater risk of revision. Deficiency anemia, obesity, drug abuse, alcohol abuse, fluid and electrolyte disorders and peripheral vascular disorders were associated with increased risk of revision (p < 0.05 for all comparisons). The total number of comorbidities and specific comorbid diseases was independently associated with an increased risk of re-operation within the first year of total hip arthroplasty. This information could be helpful in pre- and post-operative risk adjustment and patient selection. Georg Thieme Verlag KG Stuttgart · New York.

  20. Femoral offset: anatomical concept, definition, assessment, implications for preoperative templating and hip arthroplasty.

    PubMed

    Lecerf, G; Fessy, M H; Philippot, R; Massin, P; Giraud, F; Flecher, X; Girard, J; Mertl, P; Marchetti, E; Stindel, E

    2009-05-01

    BACKGROUND OBJECTIVE: Femoral offset is supposed to influence the results of hip replacement but little is known about the accurate method of measure and the true effect of offset modifications. This article is a collection of independent anatomic, radiological and clinical works, which purpose is to assess knowledge of the implications of femoral offset for preoperative templating and total hip arthroplasty. There is a strong correlation between femoral offset, abductors lever arm and hip abductor strength. Hip lateralization is independent of the femoral endomedullary characteristics. The abductors lever arm is highly correlated to the gluteus medius activation angle. There were correlations between femoral offset and endomedullary shape. The hip center was high and medial for stovepipe metaphysis while it was lower and lateralized for champagne - flute upper femur. A study was performed to compare the femoral offset measured by X-ray and CT-scan in 50 patients, demonstrated that plain radiography underestimates offset measurement. The 2D templating cannot appreciate the rotation of the lower limb. Taking into account the horizontal plane is essential to obtain proper 3D planning of the femoral offset. A randomized study was designed to compare femoral offset measurements after hip resurfacing and total hip arthroplasty. This study underlined hip resurfacing reduced the femoral offset, while hip replacement increased offset. However, the reduction of femoral offset after hip resurfacing does not affect the function. A pilot study was designed to assess the results of 120 hip arthroplasties with a modular femoral neck. This study showed that the use of a modular collar ensures an easier restoration of the femoral offset. A cohort of high offset stems (Lubinus 117 degrees) was retrospectively assessed. The survival rate was slightly lower that the standard design reported in the Swedish register. Finally, the measurement of offset and leg length was assessed with the help of computer assistance. The software changed the initial schedule (obtained by templating) in 29%. Therefore, femoral offset restoration is essential to improve function and longevity of hip arthroplasty. CT-scan is more accurate than plain radiography to assess femoral offset. Hip resurfacing decreases offset without effect on function. Modular neck and computer assistance may improve intraoperative calculation and reproduction of femoral offset. Increasing offset with a standard cemented design may decrease long-term fixation. Level IV: Retrospective or historical series.

  1. Corrosion on the acetabular liner taper from retrieved modular metal-on-metal total hip replacements.

    PubMed

    Gascoyne, Trevor C; Dyrkacz, Richard M; Turgeon, Thomas R; Burnell, Colin D; Wyss, Urs P; Brandt, Jan-M

    2014-10-01

    Eight retrieved metal-on-metal total hip replacements displayed corrosion damage along the cobalt-chromium alloy liner taper junction with the Ti alloy acetabular shell. Scanning electron microscopy indicated the primary mechanism of corrosion to be grain boundary and associated crevice corrosion, which was likely accelerated through mechanical micromotion and galvanic corrosion resulting from dissimilar alloys. Coordinate measurements revealed up to 4.3mm(3) of the cobalt-chromium alloy taper surface was removed due to corrosion, which is comparable to previous reports of corrosion damage on head-neck tapers. The acetabular liner-shell taper appears to be an additional source of metal corrosion products in modular total hip replacements. Patients with these prostheses should be closely monitored for signs of adverse reaction towards corrosion by-products. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Total hip arthroplasty using a short-stem prosthesis: restoration of hip anatomy.

    PubMed

    Amenabar, Tomas; Marimuthu, Kanniraj; Hawdon, Gabrielle; Gildone, Alessandro; McMahon, Stephen

    2015-04-01

    To evaluate hip parameters such as vertical centre of rotation (VCR), horizontal centre of rotation (HCR), femoral offset, and leg length after total hip arthroplasty (THA) using the Nanos short-stem prosthesis. Medical records of 73 men and 74 women aged 25 to 92 (mean, 63) years who underwent THA using the Nanos short-stem prosthesis by a single surgeon were reviewed. Prior to the surgery, the optimal cup and stem size, head length, and level of the neck osteotomy were determined using radiographs. Intra-operatively, the leg length and femoral offset were checked, and the level of neck resection and head length were adjusted. VCR, HCR, femoral offset, and leg length of the operated and contralateral sides were compared. Functional outcomes were assessed using the Harris Hip Score (HHS). Compared with the normal contralateral hips, the operated hips had a mean increase of 0.4 mm in VCR (p=0.032), a mean decrease of 1.4 mm in HCR (p=0.027), a mean increase of 0.6 mm in femoral offset (p=0.043), and a mean increase of 0.36 mm in leg length (p=0.035). For these respective parameters, the difference between the normal contralateral side and the operated side was within 5 mm in 89%, 80%, 71%, and 96% of patients. The HHS improved from a mean of 53 to 91 at one year (p<0.001). THA using the Nanos short-stem prosthesis enabled restoration of hip anatomy (VCR, HCR, femoral offset, and leg length).

  3. Bone mineral density of the femoral neck in resurfacing hip arthroplasty

    PubMed Central

    Ovesen, Ole; Brixen, Kim; Varmarken, Jens-Erik; Overgaard, SØren

    2010-01-01

    Background and purpose Resurfacing total hip arthroplasty (RTHA) may preserve the femoral neck bone stock postoperatively. Bone mineral density (BMD) may be affected by the hip position, which might bias longitudinal studies. We investigated the dependency of BMD precision on type of ROI and hip position. Method We DXA-scanned the femoral neck of 15 resurfacing patients twice with the hip in 3 different rotations: 15° internal, neutral, and 15° external. For each position, BMD was analyzed with 3 surface area models. One model measured BMD in the total femoral neck, the second model divided the neck in two, and the third model had 6 divisions. Results When all hip positions were pooled, average coefficients of variation (CVs) of 3.1%, 3.6%, and 4.6% were found in the 1-, 2-, and 6-region models, respectively. The externally rotated hip position was less reproducible. When rotating in increments of 15° or 30°, the average CVs rose to 7.2%, 7.3%, and 12% in the 3 models. Rotation affected the precision most in the model that divided the neck in 6 subregions, predominantly in the lateral and distal regions. For larger-region models, some rotation could be allowed without compromising the precision. Interpretation If hip rotation is strictly controlled, DXA can reliably provide detailed topographical information about the BMD changes around an RTHA. As rotation strongly affects the precision of the BMD measurements in small regions, we suggest that a less detailed model should be used for analysis in studies where the leg position has not been firmly controlled. PMID:20367420

  4. Posterosuperior Placement of a Standard-Sized Cup at the True Acetabulum in Acetabular Reconstruction of Developmental Dysplasia of the Hip With High Dislocation.

    PubMed

    Xu, Jiawei; Xu, Chen; Mao, Yuanqing; Zhang, Jincheng; Li, Huiwu; Zhu, Zhenan

    2016-06-01

    We sought to evaluate posterosuperior placement of the acetabular component at the true acetabulum during acetabular reconstruction in patients with Crowe type-IV developmental dysplasia of the hip. Using pelvic computed tomography and image processing, we developed a two-dimensional mapping technique to demonstrate the distribution of preoperative three-dimensional cup coverage at the true acetabulum, determined the postoperative location of the acetabular cup, and calculated postoperative three-dimensional coverage for 16 Crowe type-IV dysplastic hips in 14 patients with a mean age of 52 years (33-78 years) who underwent total hip arthroplasty. Mean follow-up was 6.3 years (5.5-7.3 years). On preoperative mapping, the maximum three-dimensional coverage using a 44-mm cup was 87.31% (77.36%-98.14%). Mapping enabled the successful replacement of 16 hips using a mean cup size of 44.13 mm (42-46 mm) with posterosuperior placement of the cup. Early weight-bearing and no prosthesis revision or loosening during follow-up were achieved in all patients. The postoperative two-dimensional coverage on anteroposterior radiographs and three-dimensional coverage were 96.15% (89.49%-100%) and 83.42% (71.81%-98.50%), respectively. This technique may improve long-term implant survival in patients with Crowe-IV developmental dysplasia of the hip undergoing total hip arthroplasty by allowing the use of durable bearings, increasing host bone coverage, ensuring initial stability, and restoring the normal hip center. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Mini Nutritional Assessment predicts gait status and mortality 6 months after hip fracture.

    PubMed

    Gumieiro, David N; Rafacho, Bruna P M; Gonçalves, Andrea F; Tanni, Suzana E; Azevedo, Paula S; Sakane, Daniel T; Carneiro, Carlos A S; Gaspardo, David; Zornoff, Leonardo A M; Pereira, Gilberto J C; Paiva, Sergio A R; Minicucci, Marcos F

    2013-05-01

    The aim of the present study was to evaluate the Mini Nutritional Assessment (MNA), the Nutritional Risk Screening (NRS) 2002 and the American Society of Anesthesiologists Physical Status Score (ASA) as predictors of gait status and mortality 6 months after hip fracture. A total of eighty-eight consecutive patients over the age of 65 years with hip fracture admitted to an orthopaedic unit were prospectively evaluated. Within the first 72 h of admission, each patient's characteristics were recorded, and the MNA, the NRS 2002 and the ASA were performed. Gait status and mortality were evaluated 6 months after hip fracture. Of the total patients, two were excluded because of pathological fractures. The remaining eighty-six patients (aged 80·2 (sd 7·3) years) were studied. Among these patients 76·7 % were female, 69·8 % walked with or without support and 12·8 % died 6 months after the fracture. In a multivariate analysis, only the MNA was associated with gait status 6 months after hip fracture (OR 0·773, 95 % CI 0·663, 0·901; P= 0·001). In the Cox regression model, only the MNA was associated with mortality 6 months after hip fracture (hazard ratio 0·869, 95 % CI 0·757, 0·998; P= 0·04). In conclusion, the MNA best predicts gait status and mortality 6 months after hip fracture. These results suggest that the MNA should be included in the clinical stratification of patients with hip fracture to identify and treat malnutrition in order to improve the outcomes.

  6. Accuracy of femoral templating in reproducing anatomical femoral offset in total hip replacement.

    PubMed

    Davies, H; Foote, J; Spencer, R F

    2007-01-01

    Restoration of hip biomechanics is a crucial component of successful total hip replacement. Preoperative templating is recommended to ensure that the size and orientation of implants is optimised. We studied how closely natural femoral offset could be reproduced using the manufacturers' templates for 10 femoral stems in common use in the UK. A series of 23 consecutive preoperative radiographs from patients who had undergone unilateral total hip replacement for unilateral osteoarthritis of the hip was employed. The change in offset between the templated position of the best-fitting template and the anatomical centre of the hip was measured. The templates were then ranked according to their ability to reproduce the normal anatomical offset. The most accurate was the CPS-Plus (Root Mean Square Error 2.0 mm) followed in rank order by: C stem (2.16), CPT (2.40), Exeter (3.23), Stanmore (3.28), Charnley (3.65), Corail (3.72), ABG II (4.30), Furlong HAC (5.08) and Furlong modular (7.14). A similar pattern of results was achieved when the standard error of variability of offset was analysed. We observed a wide variation in the ability of the femoral prosthesis templates to reproduce normal femoral offset. This variation was independent of the seniority of the observer. The templates of modern polished tapered stems with high modularity were best able to reproduce femoral offset. The current move towards digitisation of X-rays may offer manufacturers an opportunity to improve template designs in certain instances, and to develop appropriate computer software.

  7. The Effect of Vitamin A on Fracture Risk: A Meta-Analysis of Cohort Studies

    PubMed Central

    Zhang, Xinge; Zhang, Rui; Wang, Yueqiao; Yan, Hanyi; Wu, Yingru; Tan, Anran; Fu, Jialin; Shen, Ziqiong; Qin, Guiyu; Li, Rui; Chen, Guoxun

    2017-01-01

    This meta-analysis evaluated the influence of dietary intake and blood level of vitamin A (total vitamin A, retinol or β-carotene) on total and hip fracture risk. Cohort studies published before July 2017 were selected through English-language literature searches in several databases. Relative risk (RR) with corresponding 95% confidence interval (CI) was used to evaluate the risk. Heterogeneity was checked by Chi-square and I2 test. Sensitivity analysis and publication bias were also performed. For the association between retinol intake and total fracture risk, we performed subgroup analysis by sex, region, case ascertainment, education level, age at menopause and vitamin D intake. R software was used to complete all statistical analyses. A total of 319,077 participants over the age of 20 years were included. Higher dietary intake of retinol and total vitamin A may slightly decrease total fracture risk (RR with 95% CI: 0.95 (0.91, 1.00) and 0.94 (0.88, 0.99), respectively), and increase hip fracture risk (RR with 95% CI: 1.40 (1.02, 1.91) and 1.29 (1.06, 1.57), respectively). Lower blood level of retinol may slightly increase total fracture risk (RR with 95% CI: 1.11 (0.94, 1.30)) and hip fracture risk (RR with 95% CI: 1.27 (1.05, 1.53)). In addition, higher β-carotene intake was weakly associated with the increased risk of total fracture (RR with 95% CI: 1.07 (0.97, 1.17)). Our data suggest that vitamin A intake and level may differentially influence the risks of total and hip fractures. Clinical trials are warranted to confirm these results and assess the clinical applicability. PMID:28891953

  8. Mechanical Prophylaxis after Lower Extremity Total Joint Arthroplasty: A Review.

    PubMed

    Chughtai, Morad; Newman, Jared M; Solow, Max; Davidson, Iyooh U; Sodhi, Nipun; Gaal, Benjamin; Khlopas, Anton; Sultan, Assem A; Mont, Michael A

    2017-12-22

    Venous thromboembolism (VTE) is a serious complication that can occur after total hip and knee arthroplasty, and can potentially lead to significant morbidity and even mortality. While various modalities have been used to prevent VTE development, the medications can be associated with a number of adverse events. Therefore, mechanical prophylaxis with pumps and compressive devices has been used more frequently alone, or in combination, with medications. Therefore, the purpose of this study was to review the current literature on mechanical prophylaxis for VTEs after lower extremity total joint arthroplasty. Specifically, we reviewed mechanical prophylaxis after: 1) total hip arthroplasty and 2) total knee arthroplasty.

  9. Hip Arthroscopy Outcomes With Respect to Patient Acceptable Symptomatic State and Minimal Clinically Important Difference.

    PubMed

    Levy, David M; Kuhns, Benjamin D; Chahal, Jaskarndip; Philippon, Marc J; Kelly, Bryan T; Nho, Shane J

    2016-09-01

    To determine whether the hip arthroscopy literature to date has shown outcomes consistent with published patient acceptable symptomatic state (PASS) and minimal clinically important difference (MCID) estimates. All clinical investigations of hip arthroscopy using modified Harris Hip Score (mHHS) and/or Hip Outcome Score (HOS) outcomes with at least 1 year of follow-up were reviewed. Ninety-one studies (9,746 hips) were included for review. Eighty-one studies (9,317 hips) contained only primary hip arthroscopies and were the primary focus of this review. The remaining studies (429 hips) did not exclude patients with prior surgical history and were thus considered separately. Mean mHHS, HOS-ADL (Activities of Daily Living) and HOS-SS (Sports-Specific) scores were compared with previously published PASS and MCID values. After 31 ± 20 months, 5.8% of study populations required revision arthroscopy and 5.5% total hip arthroplasty. A total of 88%, 25%, and 30% of study populations met PASS for mHHS, HOS-ADL, and HOS-SS, respectively, and 97%, 90%, and 93% met MCID. On bivariate analysis, increasing age was associated with significantly worse postoperative mHHS (P < .01, R(2) = 0.14), HOS-SS (P = .05, R(2) = 0.12), and rates of reoperation (P = .02, R(2) = 0.08). Increasing body mass index was associated with significantly worse HOS-ADL (P = .02, R(2) = 0.35) and HOS-SS (P = .03, R(2) = 0.30). In this meta-analysis of 81 studies of primary hip arthroscopy, we have found that more than 90% of study populations meet MCID standards for the most commonly used patient-reported outcomes measures in hip arthroscopy literature, mHHS and HOS. Eighty-eight percent meet PASS standards for the mHHS, but PASS standards are far more difficult to achieve for HOS-ADL (25%) and HOS-SS (30%) subscales. Differences in psychometric properties of the mHHS and HOS likely account for the discrepancies in PASS. Level IV, systematic review of Level I to IV studies. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  10. Dynamic long leg casting fixation for treating 12- to 18-month-old infants with developmental dysplasia of the hip.

    PubMed

    Cai, Zhencun; Li, Lianyong; Zhang, Lijun; Ji, Shijun; Zhao, Qun

    2017-02-01

    Objective To evaluate the effect of dynamic long leg casting in paediatric patients with developmental dysplasia of hip (DDH) diagnosed at 12-18 months. Methods The adductor tenotomy, closed reduction, and dynamic long leg casting method was adopted to treat paediatric patients with DDH. The hips were divided into four groups according to the Tonnis radiographic dislocation classification. Groups were also classified according to the baseline acetabular index (AI): 30°-35°, 36°-40°, and > 40°. The outcomes of the reductions were evaluated according to McKay's hip function criteria and Severin's radiological criteria. Results A total of 246 patients (339 hips) had complete follow-up data. After 3 months of orthosis fixation, the results were satisfactory in 264 hips (77.88%). Hip function was rated as 'excellent' or 'good' in 43 of 51 (84.31%) Tonnis type 1 hips, 125 of 155 (80.65%) type 2 hips, 70 of 90 (77.78%) type 3 hips, and 34 of 43 (79.07%) type 4 hips. The higher the baseline AI, the lower the rates of 'excellent' and 'good' hip function. Favourable radiological results (Severin types I and II) were found in 266 of 339 (78.47) hips. Conclusions Dynamic long leg casting is an effective method for treating patients with DDH aged 12-18 months at diagnosis.

  11. Quality Indicators for Quality of Care During Hospitalization for Vulnerable Elder Persons

    DTIC Science & Technology

    2004-08-01

    hip fracture as well as all abdominal, pelvic or lower extremity surgeries above the shin, except laparoscopic surgeries, and patients with prior...24 63. Williams MA, Campbell EB, Raynor WJ, Mlynarczyk SM, Ward SE. Reducing acute confusional states in elderly patients with hip fractures ...studies of patients receiving total hip replacements) but inferior to the acceptable regimens above. Pulmonary embolism, the sequelae of deep vein

  12. Static balance according to hip joint angle of unsupported leg during one-leg standing.

    PubMed

    Cha, Ju-Hyung; Kim, Jang-Joon; Ye, Jae-Gwan; Lee, Seul-Ji; Hong, Jeong-Mi; Choi, Hyun-Kyu; Choi, Ho-Suk; Shin, Won-Seob

    2017-05-01

    [Purpose] This study aimed to determine static balance according to hip joint angle of the unsupported leg during one-leg standing. [Subjects and Methods] Subjects included 45 healthy adult males and females in their 20s. During one-leg standing on the non-dominant leg, the position of the unsupported leg was classified according to hip joint angles of point angle was class. Static balance was then measured using a force plate with eyes open and closed. The total length, sway velocity, maximum deviation, and velocity on the mediolateral and anteroposterior axes of center of pressure were measured. [Results] In balance assessment with eyes open, there were significant differences between groups according to hip joint angle, except for maximum deviation on the anteroposterior axis. In balance assessment with eyes closed, there were significant differences between total length measurements at 0° and 30°, 60° and between 30° and 90°. There were significant differences between sway velocity measurements at 0° and 30° and between 30° and 90°. [Conclusion] Thus, there were differences in static balance according to hip joint angle. It is necessary to clearly identify the hip joint angle during one-leg standing testing.

  13. Efficacy of Kirschner-wires and tension band in hip arthroplasty for aged patients with unstable intertrochanteric osteoporotic fracture

    PubMed Central

    Zhang, Hua; Xu, Zhongwei; Zhou, Aiguo; Yan, Wenlong; Zhao, Pei; Huang, Xiao; Zhang, Jian

    2017-01-01

    Abstract The aim of this study was to evaluate the efficacy of supplementary fixation in hip arthroplasty with the use of Kirschner-wires and tension band for geriatric patients suffering unstable intertrochanteric osteoporotic fractures. A total of 103 patients aged more than 75 years were recruited. A bipolar or total hip replacement was performed with additional application of Kirschner-wires and tension band, and the participants were followed up for 2 to 11 years. Physical component summary (PCS), mental component summary (MCS), visual analog scale (VAS), and Harris hip score were utilized to evaluate patients’ hip pain and function, as well as the mental condition postoperatively after 1.5 months, 3 months, 6 months, 1 year, and annually thereafter until the latest follow-up in 2015. Patients showed a significant improvement in all scores between 1.5 months and 1 year (P < 0.001), with the good efficacy lasting at least until the 2-year follow-up. None of the patients showed dislocation, implant loosening, or nonunion of the fracture throughout the follow-up period. In conclusion, it was beneficial to treat unstable intertrochanteric osteoporotic fractures in aged patients with hip arthroplasty coupled with Kirschner-wires and tension band. PMID:28072698

  14. A Two Centre Study to Assess the Stability and Long-term Performance of the C-Stem™ AMT in a Total Primary Hip Replacement

    ClinicalTrials.gov

    2017-06-23

    Rheumatoid Arthritis; Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis

  15. A Randomised Single Centre Study to Compare the Long-term Wear Characteristics of Marathon™ and Enduron™ Polyethylene Cup Liners in Primary Total Hip Replacement

    ClinicalTrials.gov

    2017-06-23

    Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis

  16. Ten-Year Outcome of Serum Metal Ion Levels After Primary Total Hip Arthroplasty

    PubMed Central

    Levine, Brett R.; Hsu, Andrew R.; Skipor, Anastasia K.; Hallab, Nadim J.; Paprosky, Wayne G.; Galante, Jorge O.; Jacobs, Joshua J.

    2013-01-01

    Abstract: We previously reported on the metal ion concentrations of cobalt, chromium, and titanium that were found in the serum of patients three years after they had undergone primary total hip arthroplasty as compared with the concentrations found in the serum of control patients who did not have an implant. This study is a concise update on the serum metal levels found in a cohort of these patients ten years after the time of hip implantation. Of the original seventy-five subjects, metal ion levels were available for forty patients (53%). Ten patients (hybrid group) had received a hybrid total hip replacement that consisted of a modular cobalt-alloy femoral stem with a cobalt-alloy femoral head that had been inserted with cement and a titanium acetabular socket that had been inserted without cement. Nine patients (cobalt-chromium [CoCr] group) had received an implant with an extensively porous-coated modular cobalt-alloy femoral stem and femoral head along with a titanium acetabular socket; the femoral and acetabular components had each been inserted without cement. Eight patients (titanium group) had undergone insertion of a proximally porous-coated modular titanium-alloy femoral stem with a cobalt-alloy femoral head and a titanium acetabular socket; the femoral and acetabular components had each been inserted without cement. Thirteen patients (control group) from the original control group of patients who had not received an implant served as control subjects. Serum metal levels were measured with use of high-resolution sector field inductively coupled plasma mass spectrometry. The hybrid total hip arthroplasty group had mean cobalt levels that were 3.2 times higher at 120 months than they were at baseline, and the cobalt levels in that group were significantly higher than those in the titanium total hip arthroplasty group at thirty-six, sixty, eighty-four, ninety-six, and 120 months (p < 0.01). The hybrid group had mean chromium levels that were 3.9 times higher at 120 months than they were at baseline, and the CoCr total hip arthroplasty group had chromium levels that were 3.6 times higher at 120 months than they were at baseline. The serum titanium levels were higher in the titanium group at all follow-up time intervals as compared with the levels in all other groups, and the level in the titanium group at 120 months was eighteen times higher than it was at baseline (p < 0.01). Patients with well-functioning primary metal-on-polyethylene total hip replacements had elevated serum metal levels for as many as ten years postoperatively. Furthermore, metal release at the modular femoral head-neck junctions, rather than passive dissolution from porous ingrowth surfaces, was likely the dominant source of serum cobalt and chromium. Level of Evidence: Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence. PMID:23515985

  17. Online follow-up after total hip replacement: a first case

    PubMed Central

    Dexter, Caroline; Bradley, Benjamin; Williams, Daniel H

    2013-01-01

    With the current challenging financial climate in the NHS there is an increasing drive to reduce the number of postoperative follow-up appointments. We report on a patient who has successfully used a new online platform, www.myclinicaloutcomes.co.uk, to record condition-specific and generic wellbeing scores following total hip replacement. This case highlights the potential for remote follow-up of routine postoperative patients. PMID:23396931

  18. Association of Body Weight and Body Mass Index with Bone Mineral Density in Women and Men from Kosovo

    PubMed Central

    Rexhepi, Sylejman; Bahtiri, Elton; Rexhepi, Mjellma; Sahatciu-Meka, Vjollca; Rexhepi, Blerta

    2015-01-01

    Background and objective: Body weight and body mass index (BMI) are considered potentially modifiable determinants of bone mass. Therefore, the aim of this study was to explore the association between body weight and body mass index (BMI) with total hip and lumbar spine bone mineral density (BMD). Methods: This cross-sectional study included a population of 100 women and 32 men from Kosovo into three BMI groups. All the study subjects underwent dual-energy X-ray absorptiometry (DXA) measurements. Results: Total hip BMD levels of obese menopausal and premenopausal women and men were significantly higher compared to overweight or normal weight subjects, while lumbar spine BMD levels of only menopausal women and men were higher among obese subjects. Age-adjusted linear regression analysis showed that BMI is a significant independent associate of lumbar spine and total hip BMD in menopausal women and men. Conclusion: Despite positive association between BMI and lumbar spine and total hip BMD in menopausal women, presence of more obese and osteoporotic subjects among menopausal women represent a population at risk for fractures because of poor balance and frequent falls; therefore, both obesity and osteoporosis prevention efforts should begin early on in life. PMID:26543419

  19. Efficacy of Multimodal Pain Control Protocol in the Setting of Total Hip Arthroplasty

    PubMed Central

    Lee, Kyung-Jae; Bae, Ki-Cheor; Cho, Chul-Hyun; Kwon, Doo-Hyun

    2009-01-01

    Background This study evaluated the benefits and safety of a multimodal pain control protocol, which included a periarticular injection of local anesthetics, in patients undergoing total hip arthroplasty. Methods Between March 2006 and March 2007, 60 patients undergoing unilateral total hip arthroplasty were randomized to undergo either a multimodal pain control protocol or a conventional pain control protocol. The following parameters were compared: the preoperative and postoperative visual analogue scales (VAS), hospital stay, operative time, postoperative rehabilitation, additional painkiller consumption, and complication rates. Results There was no difference between the groups in terms of diagnosis, age, gender, and BMI. Although both groups had similar VAS scores in the preoperative period and on the fifth postoperative day, there was a significant difference between the groups over the four-day period after surgery. There were no differences in the hospital stay, operative time, additional painkiller consumption, or complication rate between the groups. The average time for comfortable crutch ambulation was 2.8 days in the multimodal pain control protocol group and 5.3 days in the control group. Conclusions The multimodal pain control protocol can significantly reduce the level of postoperative pain and improve patients' satisfaction, with no apparent risks, after total hip arthroplasty. PMID:19885051

  20. Monitoring the quality of total hip replacement in a tertiary care department using a cumulative summation statistical method (CUSUM).

    PubMed

    Biau, D J; Meziane, M; Bhumbra, R S; Dumaine, V; Babinet, A; Anract, P

    2011-09-01

    The purpose of this study was to define immediate post-operative 'quality' in total hip replacements and to study prospectively the occurrence of failure based on these definitions of quality. The evaluation and assessment of failure were based on ten radiological and clinical criteria. The cumulative summation (CUSUM) test was used to study 200 procedures over a one-year period. Technical criteria defined failure in 17 cases (8.5%), those related to the femoral component in nine (4.5%), the acetabular component in 32 (16%) and those relating to discharge from hospital in five (2.5%). Overall, the procedure was considered to have failed in 57 of the 200 total hip replacements (28.5%). The use of a new design of acetabular component was associated with more failures. For the CUSUM test, the level of adequate performance was set at a rate of failure of 20% and the level of inadequate performance set at a failure rate of 40%; no alarm was raised by the test, indicating that there was no evidence of inadequate performance. The use of a continuous monitoring statistical method is useful to ensure that the quality of total hip replacement is maintained, especially as newer implants are introduced.

  1. In-hospital cost comparison between the standard lateral and supercapsular percutaneously-assisted total hip surgical techniques for total hip replacement.

    PubMed

    Gofton, Wade; Fitch, David A

    2016-03-01

    The purpose of this study was to compare the in-hospital costs associated with the tissue-sparing supercapsular percutaneously-assisted total hip (SuperPath) and traditional Lateral surgical techniques for total hip replacement (THR). Between April 2013 and January 2014, in-hospital costs were reviewed for all THRs performed using the SuperPath technique by a single surgeon and all THRs performed using the Lateral technique by another surgeon at the same institution. Overall, costs were 28.4% higher in the Lateral group. This was largely attributable to increased costs associated with transfusion (+92.5%), patient rooms (+60.4%), patient food (+62.8%), narcotics (+42.5%), physical therapy (+52.5%), occupational therapy (+88.6%), and social work (+92.9%). The only costs noticeably increased for SuperPath were for imaging (+105.9%), and this was because the SuperPath surgeon performed intraoperative radiographs on all patients while the Lateral surgeon did not. The use of the SuperPath technique resulted in in-hospital cost reductions of over 28%, suggesting that this tissue-sparing surgical technique can be cost-effective primarily by facilitating early mobilisation and patient discharge even during a surgeon's initial experience with the approach.

  2. Magnetic Resonance Imaging Findings in the Symptomatic Hips of Younger Retired National Football League Players.

    PubMed

    Domb, Benjamin G; Jackson, Timothy J; Carter, Christopher C; Jester, Jon R; Finch, Nathan A; Stake, Christine E

    2014-07-01

    American football players have an increased level of risk for hip injuries because of the high level of contact, biomechanical load, and anatomic strain placed on the hip joint. Many injuries are attributed to soft tissue injury rather than intra-articular lesions. However, because of improved imaging and increased knowledge, physicians are attributing unexplained hip pain to intra-articular lesions with increasing frequency. To assess the prevalence of pathologic intra-articular hip lesions in a younger, retired National Football League (NFL) player cohort evaluated for persistent hip pain. Case series; Level of evidence, 4. A retrospective chart review was performed of magnetic resonance imaging (MRI) on retired NFL players evaluated at an orthopaedic clinic for persistent hip pain. All MRIs were performed at the same location and reviewed by the same independent radiologist. The study included 62 hips; MRI was used to evaluate 27 hips, and MRI arthrogram was used to evaluate 35 hips. Images were assessed for labral tears, chondral lesions, ligamentum teres (LT) tears, bone cysts, osteophytes, loose bodies, trochanteric bursitis, and alpha angle. Player demographics, including position and seasons played, were recorded. From February 2011 to December 2012, a total of 50 retired players from the NFL (average age, 33 years; range, 27-39 years) received impairment evaluations assessing all symptomatic joints. Thirty-eight (76%) players had hip complaints and underwent a dedicated hip MRI. Twenty-four players (63%) had bilateral hip pain, for a total of 62 hips evaluated. There were 55 (89%) labral tears, 61 (98%) chondral lesions, and 50 (81%) partial or complete LT tears identified on MRI. Additional findings included 3 (5%) hips with osteophytes, 9 (14.5%) with subchondral bone cysts, and 3 (5%) with paralabral cysts. None of the players were found to have trochanteric bursitis or loose bodies. Fifty-eight of 62 alpha angles could be measured, for a mean of 59° (range, 39°-77°). The majority of players were defensive players (63%), while the remainder were offensive players (34%) and 1 special teams player. Position breakdown was as follows: 29% were defensive backs, 16% played the defensive line, 18% were linebackers, 13% were fullbacks, 11% were wide receivers, 5% played the offensive line, and the remaining 8% were kickers, running backs, and quarterbacks. This study demonstrated a high incidence of intra-articular pathologic lesions of the hip in a younger cohort of retired NFL players. The majority of players had bilateral hip pain. The most common finding was chondral lesions, followed by labral tears. Future research is needed to further elucidate incidence and treatment outcomes using prospective studies examining active and retired players with hip-related injuries. © 2014 The Author(s).

  3. Bilateral avascular necrosis of the femoral head due to the use of heroin: A case report.

    PubMed

    Ozkunt, Okan; Sarıyılmaz, Kerim; Sungur, Mustafa; Ilen, Ferhat; Dikici, Fatih

    2015-01-01

    Femoral head avascular necrosis is caused by disruption of the blood supply of the femoral head, which finally results in hip dysfunction. Non traumatic osteonecrosis may related with corticosteroid use, alcohol abuse, SLE, hemoglobinopathies or exposure to cytotoxic agents. But avascular necrosis of the femoral head (ANFH) due to heroin use is a rare condition. We report a patient with bilateral ANFH due to heroin use treated by simultaneous bilateral hip arthroplasty. 37 year-old male patient presented with bilateral hip pain that had been occurring for four years. The patient had no history of smoking, excessive drinking, using corticosteroid and the other drugs or trauma but used heroin for 10 years. In clinic and radiologic examination indicated advanced degenerative changes on both hip due to femoral head avascular necrosis. The patient was treated with simultaneous bilateral total hip arthroplasty. After 6 months postoperatively the active hip range of motion was painless. Avascular femoral head necrosis caused by the using of heroin is rare. Ultimately, osteonecrosis of the femoral head occurs through one final common pathway, which is decreased blood flow to the femoral head that leads bone ischemia and death. But it is still unknown that heroin's systemic effects. Intravenous drug use more as a serious problem for today. There is a need for comprehensive studies to demonstrate effects of heroin on bone and vascularity metabolism. Heroin use will be important problem for population. That's why is crucial to understand the effect of heroin. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Postural asymmetries in young adults with cerebral palsy.

    PubMed

    Rodby-Bousquet, Elisabet; Czuba, Tomasz; Hägglund, Gunnar; Westbom, Lena

    2013-11-01

    The purpose was to describe posture, ability to change position, and association between posture and contractures, hip dislocation, scoliosis, and pain in young adults with cerebral palsy (CP). Cross-sectional data of 102 people (63 males, 39 females; age range 19-23 y, median 21 y) out of a total population with CP was analysed in relation to Gross Motor Function Classification System (GMFCS) levels I (n=38), II (n=21), III (n=13), IV (n=10), and V (n=20). The CP subtypes were unilateral spastic (n=26), bilateral spastic (n=45), ataxic (n=12), and dyskinetic CP (n=19). The Postural Ability Scale was used to assess posture. The relationship between posture and joint range of motion, hip dislocation, scoliosis, and pain was analysed using logistic regression and Spearman's correlation. At GMFCS levels I to II, head and trunk asymmetries were most common; at GMFCS levels III to V postural asymmetries varied with position. The odds ratios (OR) for severe postural asymmetries were significantly higher for those with scoliosis (OR=33 sitting), limited hip extension (OR=39 supine), or limited knee extension (OR=37 standing). Postural asymmetries correlated to hip dislocations: supine (r(s) =0.48), sitting (r(s) =0.40), standing (r(s) =0.41), and inability to change position: supine (r(s) =0.60), sitting (r(s) =0.73), and standing (r(s) =0.64). Postural asymmetries were associated with scoliosis, hip dislocations, hip and knee contractures, and inability to change position. © 2013 The Authors. Developmental Medicine & Child Neurology published by John Wiley & Sons Ltd on behalf of Mac Keith Press.

  5. Postural asymmetries in young adults with cerebral palsy

    PubMed Central

    Rodby-Bousquet, Elisabet; Czuba, Tomasz; Hägglund, Gunnar; Westbom, Lena

    2013-01-01

    Aim The purpose was to describe posture, ability to change position, and association between posture and contractures, hip dislocation, scoliosis, and pain in young adults with cerebral palsy (CP). Methods Cross-sectional data of 102 people (63 males, 39 females; age range 19–23y, median 21y) out of a total population with CP was analysed in relation to Gross Motor Function Classification System (GMFCS) levels I (n=38), II (n=21), III (n=13), IV (n=10), and V (n=20). The CP subtypes were unilateral spastic (n=26), bilateral spastic (n=45), ataxic (n=12), and dyskinetic CP (n=19). The Postural Ability Scale was used to assess posture. The relationship between posture and joint range of motion, hip dislocation, scoliosis, and pain was analysed using logistic regression and Spearman’s correlation. Results At GMFCS levels I to II, head and trunk asymmetries were most common; at GMFCS levels III to V postural asymmetries varied with position. The odds ratios (OR) for severe postural asymmetries were significantly higher for those with scoliosis (OR=33 sitting), limited hip extension (OR=39 supine), or limited knee extension (OR=37 standing). Postural asymmetries correlated to hip dislocations: supine (rs=0.48), sitting (rs=0.40), standing (rs=0.41), and inability to change position: supine (rs=0.60), sitting (rs=0.73), and standing (rs=0.64). Conclusions Postural asymmetries were associated with scoliosis, hip dislocations, hip and knee contractures, and inability to change position. This article is commented on by Novak on page 974 of this issue. PMID:23834239

  6. Biomechanical study of pelvic discontinuity in failed total hip arthroplasty. Lessons learnt from the treatment of pelvic fractures.

    PubMed

    Ribes-Iborra, Julio; Atienza, Carlos; Sevil-De la Torre, Jorge; Gómez Pérez, Amelia

    2017-11-01

    Pelvic discontinuity is a rare but serious problem in orthopedic surgery. Acetabular reconstruction in case of severe bone loss after failed total hip arthroplasty is technically difficult, especially in segmental loss type III (anterior or posterior) or pelvic discontinuity (type IV). Acetabular reinforcement devices are frequently used as load-sharing devices to allow allograft incorporation and in order to serve as support of acetabular implants. This study tries to show, by means of biomechanic work, the efficiency of reinforced plate in anterior column in a segmental pelvic loss, illustrated with a clinical case, which shows the socket stability of hip prosthesis. © 2017 Elsevier Ltd. All rights reserved.

  7. Modular femoral neck fracture after primary total hip arthroplasty.

    PubMed

    Sotereanos, Nicholas G; Sauber, Timothy J; Tupis, Todd T

    2013-01-01

    The use of modular femoral stems in primary total hip arthroplasty has increased considerably in recent years. These modular components offer the surgeon the ability to independently alter version, offset, and length of the femoral component of a hip arthroplasty. This increases the surgeon's ability to accurately recreate the relevant anatomy but increases the possibilities of corrosion and fracture. Multiple case reports have highlighted fractures of these modular components. We present a case of a fracture of a modular design that has had no previously reported modular neck fractures. The patient was informed that data concerning the case would be submitted, and he consented. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Hip arthroscopy utilization and associated complications: a population-based analysis

    PubMed Central

    Bernard, Johnathan A.; Pan, Ting J.; Ranawat, Anil S.; Nawabi, Danyal H.; Kelly, Bryan T.; Lyman, Stephen

    2017-01-01

    Abstract The purpose of this study is to review the trends in hip arthroscopy using data from a statewide database, focusing on utilization rates, patient demographics and complication rates. The Statewide Planning and Research Cooperative System (SPARCS) database for New York State was queried for cases of hip arthroscopy from 1998 to 2012. Patient demographics and procedural details were collected. Patients were subsequently reviewed for complications and readmissions within 30 and 90 days. In total, 12 194 hip arthroscopy procedures were performed by 295 surgeons in 137 centers between 1998 and 2012. There was a 95-fold increase in the annual frequency of hip arthroscopy procedures between 1998 (n = 24) and 2012 (n = 2296). Thirty-day complication rates were 0.2% (n = 19), whereas the 90-day complication rate was 0.3% (n = 30). The all-cause 30-day readmission rate was 0.5% (n = 66), whereas the 90-day rate was 1.6% (n = 200). The number of surgeons performing hip arthroscopy increased 7-fold over the observation period. However, only 14.9% (n = 44) of surgeons performed more than 30 procedures annually. Lower volume surgeons (<102 cases/year) demonstrated significantly higher 90-day readmission rates, compared with higher volume surgeons (>163 cases/year, P < 0.0060); however, complication rates and readmission rates did not differ based on surgeon volume. Our findings confirm our hypothesis, demonstrating a significant increase in utilization of hip arthroscopy in the State of New York. We did not identify an associated increase in annual complication rates as hypothesized with increasing utilization, although there was an association of higher readmission rates among lower volume surgeons. Further study is needed to define rates of failure requiring revision hip arthroscopy or conversion to arthroplasty, and to clarify the relationship between complication rates and surgeon volume and case complexity. Level of Evidence: III, retrospective cohort series. PMID:28948036

  9. Short-Term Outcomes Following Hip Fractures in Patients at Least 100 Years Old.

    PubMed

    Manoli, Arthur; Driesman, Adam; Marwin, Rebecca A; Konda, Sanjit; Leucht, Philipp; Egol, Kenneth A

    2017-07-05

    The number of hip fractures is rising as life expectancy increases. As such, the number of centenarians sustaining these fractures is also increasing. The purpose of this study was to determine whether patients who are ≥100 years old and sustain a hip fracture fare worse in the hospital than those who are younger. Using a large database, the New York Statewide Planning and Research Cooperative System (SPARCS), we identified patients who were ≥65 years old and had been treated for a hip fracture over a 12-year period. Data on demographics, comorbidities, and treatment were collected. Three cohorts were established: patients who were 65 to 80 years old, 81 to 99 years old, and ≥100 years old (centenarians). Outcome measures included hospital length of stay, estimated total costs, and in-hospital mortality rates. A total of 168,087 patients with a hip fracture were identified, and 1,150 (0.7%) of them had sustained the fracture when they were ≥100 years old. Centenarians incurred costs and had lengths of stay that were similar to those of younger patients. Despite the similarities, centenarians were found to have a significantly higher in-hospital mortality rate than the younger populations (7.4% compared with 4.4% for those 81 to 99 years old and 2.6% for those 65 to 80 years old; p < 0.01). Male sex and an increasing number of medical comorbidities were found to predict in-hospital mortality for centenarians sustaining extracapsular hip fractures. No significant predictors of in-hospital mortality were identified for centenarians who sustained femoral neck fractures. An increased time to surgery did not influence the odds of in-hospital mortality. Centenarians had increased in-hospital mortality, but the remaining short-term outcomes were comparable with those for the younger cohorts with similar fracture patterns. For this extremely elderly population, time to surgery does not appear to affect short-term mortality rates, suggesting a potential benefit to preoperative optimization. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  10. Retrospective database study to assess the economic impact of hip fracture in the United Kingdom.

    PubMed

    Lambrelli, Dimitra; Burge, Russel; Raluy-Callado, Mireia; Chen, Shih-Yin; Wu, Ning; Schoenfeld, Michael J

    2014-11-01

    Publications containing recent, real-world data on the economic impact of hip fractures in the UK are lacking. This retrospective electronic medical records database analysis assessed medication and healthcare resource use, direct healthcare costs, and factors predicting increased resource use and costs in adult UK hip fracture patients. Data were obtained from the Clinical Practice Research Datalink linked to the Hospital Episode Statistics for adult patients hospitalized for their first hip fracture between January 1, 2006 and March 31, 2011 (index event); healthcare costs were calculated from the National Health Service perspective using 2011-2012 cost data. Data from 8028 patients were analyzed. Resource use and costs were statistically significantly higher in the year following fracture (mean total [standard deviation (SD)] cost £7359 [£14,937]) compared with the year before fracture (mean total [SD] cost £3122 [£9435]; p < 0.001), and were similar to the total amount of the index hospitalization (mean total [SD] cost £8330 [£2627]). Multivariate regression analysis (using an estimated generalized linear model) showed that older age, male gender, higher comorbidity, osteoporosis, discharge to another institution compared with home, and pre-index hospitalization and outpatient visits were associated with increased post-index hospitalization healthcare costs (all p < 0.05). Although we did not capture all pre- and post-index costs and healthcare utilization, this study provides important insights regarding the characteristics of patients with hip fracture, and information that will be useful in burden-of-illness and economic analyses.

  11. Second hip fractures at Chiang Mai University Hospital.

    PubMed

    Wongtriratanachai, Prasit; Chiewchantanakit, Siripong; Vaseenon, Tanawat; Rojanasthien, Sattaya; Leerapun, Taninnit

    2015-02-01

    Hip fractures are a major public health problem. Patients who have suffered a hip fracture have an increased risk of a subsequent hip fracture. This study examines the incidence ofsecondhip fractures and attempts to identify underlying risk factors. To examine the incidence ofsecond hip fractures in osteoporotic patients at Chiang Mai University Hospital and to identify risk factors related to second hip fractures. A retrospective review was conducted of all low-energy mechanism hip fracture patients admitted during 2008 and 2009. Analysis of second hip fractures was conducted using survival analysis and logistic regression analysis. A total of 191 patients were observed for 391.68 person-years (mean 2.05 person-years per patient). Among that group, nine second hip fractures were identified, an overall incidence rate of 0.023 second fractures per person-year. Second hip fractures tended to occur within the first year following an initial hip fracture. There were no significant differences related to either gender or comorbid medical conditions. Logistic regression analysis revealed that increased risk of a second hip fracture was associated with age (highest between 80 to 89 years) and patients who were not treated for osteoporosis following their initial fracture. The incidence of second hip fractures at Chiang Mai University Hospital was 0.023 per person-year Careful follow-up of older patients, especially those over 80, and treatment ofosteoporosis with bisphosphonate plus vitamin D and calcium supplements was correlated with a reduction in the incidence of second hip fractures.

  12. Subchondral insufficiency fracture of the femoral head in a patient with alkaptonuria.

    PubMed

    Hamada, Takahiro; Yamamoto, Takuaki; Shida, Jun-ichi; Inokuchi, Akihiko; Arizono, Takeshi

    2014-06-01

    We report a patient with alkaptonuria accompanied by bilateral rapidly destructive arthrosis of the hip. The destruction of the left hip joint with its severe functional impairment necessitated total hip arthroplasty (THA). The outcome was satisfactory. Both magnetic resonance imaging (MRI) and pathologic findings were compatible with a subchondral insufficiency fracture. A year and half later, during a follow-up visit, the patient complained of right coxalgia. Radiography showed that the right femoral head had already disappeared, requiring THA of the right hip. Although there have been a few reports of rapid destructive hip osteoarthritis associated with ochronotic arthropathy, the pathogenesis of the destructive change is not clear. Subchondral insufficiency fracture was diagnosed on MR imaging and pathologically confirmed in our patient with alkaptonuria, suggesting that subchondral insufficiency fracture is one of the causes of ochronotic hip destruction.

  13. OBSERVATIONS OF HIERARCHICAL SOLAR-TYPE MULTIPLE STAR SYSTEMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roberts, Lewis C. Jr.; Tokovinin, Andrei; Mason, Brian D.

    2015-10-15

    Twenty multiple stellar systems with solar-type primaries were observed at high angular resolution using the PALM-3000 adaptive optics system at the 5 m Hale telescope. The goal was to complement the knowledge of hierarchical multiplicity in the solar neighborhood by confirming recent discoveries by the visible Robo-AO system with new near-infrared observations with PALM-3000. The physical status of most, but not all, of the new pairs is confirmed by photometry in the Ks band and new positional measurements. In addition, we resolved for the first time five close sub-systems: the known astrometric binary in HIP 17129AB, companions to the primariesmore » of HIP 33555, and HIP 118213, and the companions to the secondaries in HIP 25300 and HIP 101430. We place the components on a color–magnitude diagram and discuss each multiple system individually.« less

  14. Surface evaluation of orthopedic hip implants marketed in Brazil

    NASA Astrophysics Data System (ADS)

    Souza, M. M.; Trommer, R. M.; Maru, M. M.; Roesler, C. R. M.; Barros, W. S.; Dutra, M. S.

    2016-07-01

    One of the factors that contribute to the quality of total hip prostheses is the degree of accuracy in the manufacturing of the joint surfaces. The dimensional control of joint components is important because of its direct influence on the durability and, consequently, in the patients’ life quality. This work presents studies on the form and roughness of orthopedic hip prostheses marketed in Brazil. The results provide data for quality control of the surfaces of the femoral heads and acetabular components of hip prostheses and indicate the need of improvement in the procedures used to this control.

  15. Association of Hip Radiograph Findings With Pain and Function in Patients Presenting With Low Back Pain.

    PubMed

    Prather, Heidi; Cheng, Abby; Steger-May, Karen; Maheshwari, Vaibhav; VanDillen, Linda

    2018-01-01

    Relationships between low back pain (LBP) and the hip in patient cohorts have been described primarily in patients with moderate to severe hip osteoarthritis (OA). Less is known about the links of LBP with hip radiographic findings of hip deformity and minimal OA. To describe the incidence of radiographic hip deformity or hip OA; to describe and compare spine- and hip-related pain and function in the subset of patients who were found to have radiographic hip deformity or hip OA; and to compare patients with evidence of radiographic hip deformity or hip OA to patients without hip radiographic findings. Prospective cohort study with cross-sectional design. Tertiary university. A total of 63 patients (40 women, 23 men) with a mean age of 48.5 ± 14 years with LBP and a minimum of one positive provocative hip test. Hip radiographs were assessed by an independent examiner for hip OA and deformity. Comparisons of hip and lumbar spine pain and function were completed for patients with radiographic findings of hip OA or deformity. Moderate to severe hip OA was found in 12 of 60 patients (20.0%). At least one measurement of femoroacetabular impingement (FAI) was found in 14 of 60 patients (23.3%) to 33 of 45 patients (73.3%). At least one measurement of developmental hip dysplasia (DDH) was found in 7 of 60 patients (11.6%) to 11 of 63 patients (17.4%). Greater pain and reduced hip and lumbar spine function were found in the patients with moderate to severe hip OA. Patients with LBP and FAI were found to have significantly greater extremes of pain and reduced lumbar spine function. Links between the hip and the spine affecting pain and function may be found in patients with LBP and hip deformity and before the onset of radiographic hip OA, and may be associated with hip deformity. Further investigation is needed to better understand these links and their potential impact on prognosis and treatment of LBP. II. Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  16. A Randomised Single Centre Study to Compare the Long-term Performance of 4 Designs of the DePuy Ultima LX Stem in Primary Total Hip Replacement

    ClinicalTrials.gov

    2016-05-09

    Osteoarthritis; Post-traumatic Arthritis; Collagen Disorder; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis

  17. A Study to Assess the Long-term Performance of SmartSet® HV and SmartSet® GHV Bone Cements in Primary Total Hip Replacement

    ClinicalTrials.gov

    2017-03-02

    Rheumatoid Arthritis; Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis

  18. A Single Centre Study to Assess the Long-term Performance of the Pinnacle™ Cup With a Ceramic-on-ceramic Bearing in Primary Total Hip Replacement

    ClinicalTrials.gov

    2016-10-06

    Rheumatoid Arthritis; Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis

  19. A Multi-centre Study to Assess the Long-term Performance of the Pinnacle™ Cup With a Polyethylene-on-metal Bearing in Primary Total Hip Replacement

    ClinicalTrials.gov

    2017-06-27

    Rheumatoid Arthritis; Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis

  20. A Two Centre Study to Assess the Long-term Performance of the Pinnacle™ Cup With a Metal-on-Metal Bearing in Primary Total Hip Replacement

    ClinicalTrials.gov

    2016-10-06

    Rheumatoid Arthritis; Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis

  1. Effectiveness of clinical pathways for total knee and total hip arthroplasty: literature review.

    PubMed

    Kim, Stephen; Losina, Elena; Solomon, Daniel H; Wright, John; Katz, Jeffrey N

    2003-01-01

    Although many hospitals have implemented clinical pathways to standardize the process of care, the effectiveness of clinical pathways for total hip and knee arthroplasties has not been reviewed critically. We searched for articles comparing outcomes of total hip or knee arthroplasty for patients who were treated using clinical pathways as opposed to patients treated without these pathways. Eleven studies met criteria for inclusion. Ten used historical controls, and 1 was a randomized trial. The studies had important methodological limitations. In general, the articles showed that patients treated using pathways experienced shorter hospital stays and lower costs, with comparable clinical outcomes as compared with patients treated without clinical pathways. We concluded that clinical pathways appear successful in reducing costs and length of stay in the acute care hospital, with no compromise in patient outcomes. However, interpretation of these studies is complicated by substantial methodological limitations, particularly the use of historical controls and failure to account for length of stay in rehabilitation facilities. Copyright 2003, Elsevier Science (USA). All rights reserved.

  2. Ipsilateral hip abductor weakness after inversion ankle sprain.

    PubMed

    Friel, Karen; McLean, Nancy; Myers, Christine; Caceres, Maria

    2006-01-01

    Hip stability and strength are important for proper gait mechanics and foot position during heel strike. To determine the relationships between hip muscle strength and chronic ankle sprains and hip muscle strength and ankle range of motion. Ex post facto design with the uninvolved limb serving as the control. Laboratory. A total of 23 subjects with unilateral chronic ankle sprain were recruited. Subjects had at least 2 ipsilateral ankle sprains and were bearing full weight, with the most recent injury occurring at least 3 months earlier. They were not undergoing formal or informal rehabilitation at the time of the study. We obtained goniometric measurements for all planes of motion at the ankle. Handheld dynamometry was used to assess the strength of the hip abductor and hip extensor muscles in both limbs. Hip abductor muscle strength and plantar flexion were significantly less on the involved side than the uninvolved side (P < .001 in each case). Strength of the involved hip abductor and hip extensor muscles was significantly correlated (r = 0.539, P < .01). No significant difference was noted in hip extensor muscle strength between sides (P = .19). Our subjects with unilateral chronic ankle sprains had weaker hip abduction strength and less plantar-flexion range of motion on the involved sides. Clinicians should consider exercises to increase hip abduction strength when developing rehabilitation programs for patients with ankle sprains.

  3. Sex and growth effect on pediatric hip injuries presenting to sports medicine clinic.

    PubMed

    Stracciolini, Andrea; Yen, Yi-Meng; d'Hemecourt, Pierre A; Lewis, Cara L; Sugimoto, Dai

    2016-07-01

    To compare sports-related hip injuries on the basis of sex and age in a cohort of young athletes. A 5% random probability sample of all new patients' charts over a 10-year time period was selected for investigation. The most common hip injury diagnoses, sport at time of injury, mechanism (acute/traumatic vs. overuse), and types (bony vs. soft tissue) were compared by sex and age (preadolescent vs. adolescent). Descriptive and χ-analyses were carried out. The interaction of sex and age with respect to hip injury over time was examined by two-way (sex, age) analysis of variance. A total of 2133 charts were reviewed; N=87 hip injuries. The main diagnoses for males included labral tear (23.1%), avulsion fracture (11.5%), slipped capital femoral epiphysis (11.5%), dislocation (7.7%), and tendonitis (7.7%). The main diagnoses for females were labral tear (59.0%), tendonitis (14.8%), snapping hip syndrome (6.6%), strain (4.9%), and bursitis (4.9%). The five most common sports/activities at the time of hip injury were dancing/ballet (23.0%), soccer (18.4%), gymnastics (9.2%), ice hockey (8.1%), and track and field (6.9%). Age by sex comparisons showed a greater proportion of the total hip injuries (38.5%) in males compared with females (8.2%) during preadolescence (5-12 years). However, in adolescence (13-17 years), the hip injury proportion was significantly higher in females (91.8%) compared with males (61.5%; P<0.001). Injury mechanism and type differed by sex, with females sustaining more chronic/overuse (95.1%) and soft tissue type injuries (93.4%) compared with males (50.0 and 53.8%, respectively; P<0.001). Females were found to have a sharper increase in hip injury proportion as they progressed through puberty compared with males (analysis of variance sex-by-age interaction; P<0.001). Hip injury mechanism and type differed significantly between males and females during growth. Notably, the proportion of hip injuries in the young female athletes showed a significantly greater increase with advancing age compared with males. Hip injuries in children and the interplay with growth, as it relates to injury predisposition, require further investigation to facilitate efforts aimed at prevention. Cross-sectional epidemiological study.

  4. Outcomes of Revision Hip Arthroscopy: 2-Year Clinical Follow-up.

    PubMed

    Gupta, Asheesh; Redmond, John M; Stake, Christine E; Dunne, Kevin F; Hammarstedt, Jon E; Domb, Benjamin G

    2016-05-01

    To evaluate clinical outcomes, pain, and patient satisfaction following revision hip arthroscopy with a minimum 2-year follow-up. From April 2008 to October 2011, data were prospectively collected on all patients undergoing revision hip arthroscopy. All patients were assessed pre- and postoperatively with 4 patient-reported outcome (PRO) measures: the modified Harris hip score (mHHS), nonarthritic hip score (NAHS), hip outcome score-activities of daily living (HOS-ADL), and hip outcome score-sport-specific subscales (HOS-SSS). Pain was estimated on the visual analog scale (VAS). Patient satisfaction was measured on a scale from 0 to 10. The number of patients who underwent subsequent revision arthroscopy or total hip arthroplasty during the study period is also reported. Eighty-seven patients underwent revision hip arthroscopy during the study period. Seventy (80.5%) patients were included in our study. Average follow-up time was 28 months (range, 20 to 47.4 months). In terms of residual femoroacetabular impingement morphology, 45.7% of patients had preoperative alpha angles ≥ 55°, and 7.14% of patients had a lateral center-edge angle ≥ 40°. The score improvement from preoperative to 2-year follow-up was 57.84 to 73.65 for mHHS, 62.79 to 83.04 for HOS-ADL, 37.33 to 54.93 for HOS-SSS, and 55.65 to 70.79 for NAHS. VAS decreased from 6.72 to 4.08. All scores demonstrated statistically significant improvement (P < .001). Overall patient satisfaction was 7.67. Our success rate was 74.58%. Ten (14.29%) patients underwent total hip arthroplasty during the study period. Our hip survivorship was 85.7%. Five (7.14%) patients underwent secondary revision hip arthroscopy during the study period. We found an overall minor complication rate of 10%. Revision hip arthroscopy for all procedures performed on aggregate has improved clinical outcomes for all PROs, high survivorship, and high patient satisfaction scores at short-term follow-up. Patients should be counseled regarding the potential progression of degenerative change leading to arthroplasty and the potential for revision surgery. Level IV retrospective case series. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  5. [A method to avoid lengthening lower limbs after total hip arthroplasty in patients with congenital short femoral neck].

    PubMed

    Chen, Tao; Shang, Xifu; He, Rui; Hu, Fei; Ge, Chang

    2012-03-01

    To investigate the method to avoid lengthening lower limbs after total hip arthroplasty in patients with congenital short femoral neck. The clinical data were analyzed retrospectively from 38 patients undergoing unilateral total hip arthroplasty between April 2005 and December 2010. There were 26 males and 12 females, aged 45-78 years (mean, 62.3 years). Among these cases, there were 11 cases of avascular necrosis of the femoral head, 17 cases of hip osteoarthritis, and 10 cases of femoral neck fracture. Before operation, 29 cases had leg length discrepancy; and the shortened length of the legs was 10-24 mm with an average of 14.5 mm by clinical measurement, and was 11-25 mm with an average of 14.7 mm by X-ray film measurement. The Harris score before operation was 44.0 +/- 3.6. At 1 day after operation, 3 cases had legs lengthening by clinical and X-ray film measurement; limb length difference less than 10 mm was regarded as equal limb length in the other 35 patients (92.1%). All incisions healed by first intention, and no complication of infection or lower limb deep venous thrombosis occurred. In 3 patients who had legs lengthening, 1 patient had abnormal gait and slight limping after increasing heel pad because the lower limb was lengthened by 16 mm, and 2 patients had slight limping. The other patients could walk normally and achieved pain relief of hip. Thirty-six patients were followed up 12-68 months (mean, 43.8 months). The Harris score was 86.7 +/- 2.3 after 6 months, showing significant difference (t = 3.260, P = 0.031) when compared with that before operation. The X-ray films showed no prosthetic loosening or subsidence. For patients with congenital short femoral neck during total hip arthroplasty, the surgeons should pay attention to osteotomy plane determination, limb length measurement, and use of the prosthesis with collar to avoid the lengthening lower limbs.

  6. The effect of a single infusion of zoledronic acid on early implant migration in total hip arthroplasty. A randomized, double-blind, controlled trial.

    PubMed

    Friedl, Gerald; Radl, Roman; Stihsen, Christoph; Rehak, Peter; Aigner, Reingard; Windhager, Reinhard

    2009-02-01

    Aseptic loosening is the most frequent cause of implant failure in total hip arthroplasty. While a direct link between aseptic loosening and periprosthetic bone loss remains elusive, there is plentiful evidence for a close association with early implant migration. The present trial was primarily designed to evaluate whether a single infusion of 4 mg of zoledronic acid prevented early implant migration in patients with osteonecrosis of the femoral head. Fifty patients were consecutively enrolled to receive either zoledronic acid or saline solution after cementless total hip arthroplasty. Radiographs, biochemical parameters of bone turnover, and the Harris hip-rating score were determined preoperatively and at each follow-up examination at seven weeks, six months, one year, and yearly thereafter. The median follow-up period was 2.8 years. We found a significant subsidence of the stem of up to a mean (and standard deviation) of -1.2 +/- 0.6 mm at two years within the control group, and the cups had a mean medialization of 0.6 +/- 1.0 mm and a mean cranialization of 0.6 +/- 0.8 mm (p < 0.001). Treatment with zoledronic acid effectively minimized the migration of the cups in both the transverse and the vertical direction (mean, 0.15 +/- 0.6 mm and 0.06 +/- 0.6 mm, respectively; p < 0.05), while only a trend to decreased subsidence of the stem was detected. Finally, the Harris hip score rapidly increased over time in both treatment groups, although this increase was significantly more pronounced in the zoledronate-treated group than in the control group (analysis of variance, p = 0.008). A single infusion of zoledronic acid shows promise in improving initial fixation of a cementless implant, which may improve the clinical outcome of total hip arthroplasty in patients with osteonecrosis of the femoral head.

  7. Corrosion and Tribology of Materials Used in a Novel Reverse Hip Replacement.

    PubMed

    Braddon, Linda; Termanini, Zafer; MacDonald, Steven; Parvizi, Jay; Lieberman, Jay; Frankel, Victor; Zuckerman, Joseph

    2017-07-05

    Total hip arthroplasty has been utilized for the past 50 years as an effective treatment for degenerative, inflammatory and traumatic disorders of the hip. The design of these implants has generally followed the anatomy of the hip as a ball and socket joint with the femoral head representing the ball and the acetabulum representing the socket. We describe a novel hip arthroplasty design in which the "ball" is located on the acetabular side and the "socket" is located on the femoral side. The results of extensive biomechanical testing are described and document wear and corrosion characteristics that are at least equivalent to standard designs. These results support clinical assessment as the next step of the evaluation.

  8. Corrosion and Tribology of Materials Used in a Novel Reverse Hip Replacement

    PubMed Central

    Braddon, Linda; Termanini, Zafer; MacDonald, Steven; Parvizi, Jay; Lieberman, Jay; Frankel, Victor; Zuckerman, Joseph

    2017-01-01

    Total hip arthroplasty has been utilized for the past 50 years as an effective treatment for degenerative, inflammatory and traumatic disorders of the hip. The design of these implants has generally followed the anatomy of the hip as a ball and socket joint with the femoral head representing the ball and the acetabulum representing the socket. We describe a novel hip arthroplasty design in which the “ball” is located on the acetabular side and the “socket” is located on the femoral side. The results of extensive biomechanical testing are described and document wear and corrosion characteristics that are at least equivalent to standard designs. These results support clinical assessment as the next step of the evaluation. PMID:28773112

  9. Redesigning a joint replacement program using Lean Six Sigma in a Veterans Affairs hospital.

    PubMed

    Gayed, Benjamin; Black, Stephen; Daggy, Joanne; Munshi, Imtiaz A

    2013-11-01

    In April 2009, an analysis of joint replacement surgical procedures at the Richard L. Roudebush Veterans Affairs Medical Center, Indianapolis, Indiana, revealed that total hip and knee replacements incurred $1.4 million in non-Veterans Affairs (VA) care costs with an average length of stay of 6.1 days during fiscal year 2008. The Joint Replacement Program system redesign project was initiated following the Vision-Analysis-Team-Aim-Map-Measure-Change-Sustain (VA-TAMMCS) model to increase efficiency, decrease length of stay, and reduce non-VA care costs. To determine the effectiveness of Lean Six Sigma process improvement methods applied in a VA hospital. Perioperative processes for patients undergoing total joint replacement were redesigned following the VA-TAMMCS model--the VA's official, branded method of Lean Six Sigma process improvement. A multidisciplinary team including the orthopedic surgeons, frontline staff, and executive management identified waste in the current processes and initiated changes to reduce waste and increase efficiency. Data collection included a 1-year baseline period and a 20-month sustainment period. The primary endpoint was length of stay; a secondary analysis considered non-VA care cost reductions. Length of stay decreased 36% overall, decreasing from 5.3 days during the preproject period to 3.4 days during the 20-month sustainment period (P < .001). Non-VA care was completely eliminated for patients undergoing total hip and knee replacement at the Richard L. Roudebush Veterans Affairs Medical Center, producing an estimated return on investment of $1 million annually when compared with baseline cost and volumes. In addition, the volume of total joint replacements at this center increased during the data collection period. The success of the Joint Replacement Program demonstrates that VA-TAMMCS is an effective tool for Lean and Six Sigma process improvement initiatives in a surgical practice, producing a 36% sustained reduction in length of stay and completely eliminating non-VA care for total hip and knee replacements while increasing total joint replacement volume at this medical center.

  10. MRSA-infected external iliac artery pseudoaneurysm treated with endovascular stenting.

    PubMed

    Clarke, M G; Thomas, H G; Chester, J F

    2005-01-01

    A 48-year-old woman with severe juvenile-onset rheumatoid arthritis presented with a bleeding cutaneous sinus distal to her right total hip replacement scar. Methicillin resistant Staphylococcus aureus (MRSA) was isolated on culture. She had previously undergone bilateral total hip and knee replacements at aged 23 and six years later had the right knee prosthesis removed for infection, with subsequent osteomyelitis of the femoral shaft and right total hip prosthesis disruption. Peripheral arteriography was performed in view of persistent bleeding from the sinus, which revealed a 6 cm false aneurysm filling from and compressing the right external iliac artery (EIA). A PTFE-covered, balloon expandable JOSTENT was deployed in the right EIA, successfully excluding the false aneurysm and preventing further bleeding from the sinus. No graft infection was reported at 12 months. This case illustrates the potential use of endovascular stent-grafting in the treatment of an infected pseudoaneurysm.

  11. Recovery of Posture Stability at Different Foot Placements in Patients Who Underwent Minimally Invasive Total Hip Arthroplasty: A One-Year Follow-Up Study.

    PubMed

    Chang, Chun-Ju; Lin, Na-Ling; Lee, Mel S; Chern, Jen-Suh

    2015-01-01

    To understand the progression of recovery in postural stability and physical functioning after patients received the minimally invasive total hip arthroplasty (MTHA), we monitor the pain level, functional capacity, and postural stability before and after operation within one year. In total of 23 subjects in our study, we found out that MTHA was effective in relieving pain in first 2 weeks and restoring the hip joint integrity, but the postural stability was influenced especially in tandem stand in both anterior-posterior and medial-lateral directions. The recovery of postural stability and functional capacity in one year duration fluctuated and no consistent improvement tendency was found. We suggested clinicians designing postsurgery rehabilitation program for consistent and progressive long-term recovery of postural stability and fall prevention to optimize surgical results and prevent undesired postoperative consequences.

  12. MRSA-Infected External Iliac Artery Pseudoaneurysm Treated with Endovascular Stenting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clarke, M.G.; Thomas, H.G.; Chester, J.F.

    2005-04-15

    A 48-year-old woman with severe juvenile-onset rheumatoid arthritis presented with a bleeding cutaneous sinus distal to her right total hip replacement scar. Methicillin resistant Staphylococcus aureus (MRSA) was isolated on culture. She had previously undergone bilateral total hip and knee replacements at aged 23 and six years later had the right knee prosthesis removed for infection, with subsequent osteomyelitis of the femoral shaft and right total hip prosthesis disruption. Peripheral arteriography was performed in view of persistent bleeding from the sinus, which revealed a 6 cm false aneurysm filling from and compressing the right external iliac artery (EIA). A PTFE-covered,more » balloon expandable JOSTENT was deployed in the right EIA, successfully excluding the false aneurysm and preventing further bleeding from the sinus. No graft infection was reported at 12 months. This case illustrates the potential use of endovascular stent-grafting in the treatment of an infected pseudoaneurysm.« less

  13. Change in Bone Mineral Density During Weight Loss with Resistance Versus Aerobic Exercise Training in Older Adults.

    PubMed

    Beavers, Kristen M; Beavers, Daniel P; Martin, Sarah B; Marsh, Anthony P; Lyles, Mary F; Lenchik, Leon; Shapses, Sue A; Nicklas, Barbara J

    2017-10-12

    To examine the effect of exercise modality during weight loss on hip and spine bone mineral density (BMD) in overweight and obese, older adults. This analysis compared data from two 5-month, randomized controlled trials of caloric restriction (CR; inducing 5-10% weight loss) with either resistance training (RT) or aerobic training (AT) in overweight and obese, older adults. Participants in the RT + CR study underwent 3 days/week of 8 upper/lower body exercises (3 sets, 10 repetitions at 70% 1 RM) and participants in the AT+CR study underwent 4 days/week of treadmill walking (30 min at 65-70% heart rate reserve). BMD at the total hip, femoral neck, and lumbar spine was assessed via dual-energy X-ray absorptiometry at baseline and 5 months. A total of 123 adults (69.4 ± 3.5 years, 67% female, 81% Caucasian) participated in the RT+CR (n = 60) and AT+CR (n = 63) interventions. Average weight loss was 5.7% (95% CI: 4.6-6.7%) and 8.2% (95% CI: 7.2-9.3%) in RT+CR and AT+CR groups, respectively. After adjustment for age, gender, race, baseline BMI and BMD, and weight change, differential treatment effects were observed for total hip and femoral neck (both p < .05), but not lumbar spine. Total hip (1.83 [-3.90, 7.55] mg/cm2) and femoral neck (9.14 [-0.70, 18.98] mg/cm2) BMD was unchanged in RT+CR participants, and modestly decreased in AT+CR participants (total hip: -7.01 [-12.73, -1.29] mg/cm2; femoral neck: -5.36 [-14.92, 4.20] mg/cm2). Results suggest performing resistance, rather than aerobic, training during CR may attenuate loss of hip and femoral neck BMD in overweight and obese older adults. Findings warrant replication from a long-term, adequately powered, RCT. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. The Fate of the Iliopsoas Muscle in Long-term Follow-up After Open Reduction With a Medial Approach in Developmental Dysplasia of the Hip. Part 2: Isokinetic Muscle Strength Evaluation.

    PubMed

    Yilmaz, Serdar; Aksahin, Ertugrul; Ersoz, Murat; Bicimoglu, Ali

    2017-09-01

    The impact on long-term weakness of hip flexion of complete iliopsoas tenotomy during open reduction of developmental hip dysplasia with a medial approach has not yet been fully clarified. The purpose of this study was to investigate the isokinetic muscle strength (IMS) of hip flexor and extensor muscles in these patients and also to analyze the effect of spontaneous reattachment of the iliopsoas muscle on IMS measurements. The study included 20 patients. Earlier magnetic resonance imaging examination of all the patients revealed spontaneous reattachment of the iliopsoas in 18 (90%) patients. IMS measurements were performed at 60 and 150 degrees/s. The peak torque, total work (TW), average power (AP), work fatigue, and agonist to antagonist muscle ratio of the operated and nonoperated hips were recorded separately for flexors and extensors. The effect of iliopsoas reattachment on IMS was also evaluated. The mean follow-up period was 16.65±2.16 (13 to 20) years. Total work (P=0.013) and average power (P=0.009) of the flexor muscles and work fatigue of the extensor muscles (P=0.030) of the operated hip were significantly decreased when compared with the nonoperated hips at 150 degrees/s. There was no significant difference between the flexor muscles of the operated and nonoperated hips (P<0.05) at 60 degrees/s and extensor muscles (P<0.05) at 150 degrees/s. In addition, patients without reattachment had lower IMS in the operated hips. Flexor muscle strength was decreased in the operated hip against low resistance in long-term follow-up after iliopsoas tenotomy. This may reflect that hip muscle strength was decreased after prolonged activities such as sports. However, in forceful activities flexor muscle strength was retained due to iliopsoas reattachment. On the basis of this study we thought that spontaneous reattachment of the iliopsoas tendon substantially preserves muscle strength. Nonetheless possible efforts should be made to surgically reattach the psoas tendon to preserve strength of the muscle. Therapeutic level IV.

  15. Hip preserving surgery with concentrated autologous bone marrow aspirate transplantation for the treatment of asymptomatic osteonecrosis of the femoral head: retrospective review of clinical and radiological outcomes at 6 years postoperatively.

    PubMed

    Tomaru, Yohei; Yoshioka, Tomokazu; Sugaya, Hisashi; Aoto, Katsuya; Wada, Hiroshi; Akaogi, Hiroshi; Yamazaki, Masashi; Mishima, Hajime

    2017-07-06

    We had previously established concentrated autologous bone marrow aspirate transplantation (CABMAT), a one-step, low-invasive, joint-preserving surgical technique for treating osteonecrosis of the femoral head (ONFH). The present study aimed to evaluate the effects of CABMAT as a hip preserving surgical approach, preventing femoral head collapse in asymptomatic ONFH. In total, 222 patients (341 hips) with ONFH were treated with CABMAT between April 2003 and March 2013. Based on magnetic resonance imaging, we determined that 119 of these patients had bilateral asymptomatic ONFH (238 hips), and 38 further patients had unilateral asymptomatic ONFH (38 hips). In this series, we retrospectively examined 31 hips in 31 patients with unilateral asymptomatic ONFH treated surgically between 2003 and 2012 and followed up for more than 2 years. Clinical and radiological evaluation were performed immediately before the procedure and at the final follow-up. The two-year follow-up rate among patients with unilateral ONFH was 82% (31/38). Therefore, the present study included 31 patients (19 males and 12 females), with a mean age and follow-up period of 40 and 5.8 years, respectively. Of the 31 asymptomatic hips, 5, 6, 10, and 10 had osteonecrosis of types A, B, C1, and C2, respectively. The diagnosis, classification, and staging of ONFH were based on the 2001 Japanese Orthopaedic Association (JOA) classification. Secondary collapse of the femoral head was observed in 6/10 hips and 5/10 hips with osteonecrosis of types C1 and C2, respectively. Total hip arthroplasty was performed in 9.6% of patients (3/31 hips), at an average of 33 months after surgery. Clinical symptoms improved after surgery, and the secondary collapse rate at a mean of 5.8 years after CABMAT was lower than that reported in several previous studies on the natural course of asymptomatic ONFH. Early diagnosis of ONFH (i.e., before femoral head collapse) and early intervention with CABMAT could improve the clinical outcome of corticosteroid and alcohol-induced ONFH.

  16. Could larger diameter of 4th generation ceramic bearing decrease the rate of dislocation after THA?

    PubMed

    Lee, Young-Kyun; Ha, Yong-Chan; Jo, Woo-Lam; Kim, Tae-Young; Jung, Woon-Hwa; Koo, Kyung-Hoi

    2016-05-01

    Fourth generation (Delta) ceramic bearing was developed to reduce dislocation after total hip arthroplasty (THA) by increasing the head diameter. We tested a hypothesis that 32/36 mm Delta ceramic bearing decreases the dislocation rate. We also evaluated ceramic-related complications and early outcome of this thin liner-on-large head ceramic bearing. We performed a prospective study on patients who underwent THA with use of 32/36 mm Delta ceramic bearing. The dislocation rate was compared with the historical dislocation rate of third generation 28 mm ceramic bearing. We also evaluated ceramic fracture, squeak, short-term results and survival. Follow-up period was minimum 2 years. Between April 2010 and February 2012, we enrolled 250 consecutive patients (278 hips). All patients received cementless prostheses. Four patients (4 hips) who received metal shells ≤ 46 mm and 28 mm heads were excluded. Three patients died and 2 patients were lost within 2 years. The remaining 241 patients (269 hips) were followed for 24-46 months. There were 142 men (161 hips) and 99 women (108 hips) with a mean age of 53.7 years (range, 17-75 years) at the index operation. Dislocation occurred in three hips (1.1%). An old age was a risk factor for dislocation. Ceramic fracture and squeaking did not occur in any patient. Mean Harris hip score was 90.3 points at the latest follow-up. All acetabular and femoral components had bone-ingrowth stability. No hip had detectable wear or osteolysis. The survival was 99.3% in the best case scenario and 97.8% in the worst at 48 months. Total hip arthroplasty with use of 32/36 mm Delta ceramic bearing showed lower incidence of hip dislocation compared with 28 mm third generation ceramic bearing. A caution should be paid to prevent a fall in senile patients even though a large head is used. The short-term results of THA with this type of ceramic articulation are encouraging and we did not find any ceramic-related complications. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  17. Surgical Dislocation of the Hip for the Treatment of Pre-Arthritic Hip Disease.

    PubMed

    Beaulé, Paul E; Singh, Amardeep; Poitras, Stéphane; Parker, Gillian

    2015-09-01

    The purpose of this study was to report the clinical results of surgical dislocation of the hip in the treatment of pre-arthritic hip disease. Between 2005 and 2010, eighty-two patients (89 hips) underwent a surgical dislocation of the hip at a mean age of 30.5 years (range 14.8-51.7); 10 females and 72 males. At a mean follow-up of 7.1 years (range 5-9.6) clinical function improved significantly. 6 patients were converted to total hip arthroplasty and 3 patients underwent an arthroscopy and an additional three patients had >1mm of joint space narrowing at latest follow-up giving us a 9-year cumulative Kaplan-Meier survivorship of 86.4% (CI, 79% to 94%). Thirty-four patients underwent internal fixation removal at a mean of 12.0 months (range 0.3-40.8 months). Although effective in the treatment of early hip disease, the surgical dislocation approach carries a high re-operation rate for removal of internal fixation; consequently, less invasive approaches should be considered for less complex deformities. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Current expert views on metal-on-metal hip resurfacing arthroplasty. Consensus of the 6th advanced Hip resurfacing course, Ghent, Belgium, May 2014.

    PubMed

    Van Der Straeten, Catherine; De Smet, Koen A

    2016-01-01

    This paper reports the consensus of an international faculty of expert metal-on-metal (MoM) hip resurfacing surgeons, with a combined experience of over 40,000 cases, on the current status of hip resurfacing arthroplasty. Indications, design and metallurgy issues, release of metal ions and adverse soft tissue reactions to particles, management of problematic cases and revisions, as well as required experience and training are covered. The overall consensus is that MoM hip resurfacing should not be banned and should be viewed separately from MoM total hip arthroplasty (THA) with a large diameter head because of the different design and wear behaviour related to the taper/trunnion connection. The use of hip resurfacing has decreased worldwide but specialist centres continue to advocate hip resurfacing in young and active male patients. Regarding age the general recommendation is to avoid hip resurfacing in men older than 65 and in women older than 55, depending on the patient activity and bone quality. Female gender is considered a relative contraindication. Most surgeons would not implant a MoM hip in women who would still like a child. Regardless of gender, there is a consensus not to perform hip resurfacing in case of a femoral head size smaller than 46 mm and in patients with renal insufficiency or with a known metal allergy. Regarding follow-up of hip resurfacing and detection of adverse local tissue reactions, metal ion measurements, MRI and ultrasound are advocated depending on the local expertise. The consensus is that hip resurfacing should be limited to high volume hip surgeons, who are experienced in hip resurfacing or trained to perform hip resurfacing in a specialist centre.

  19. Cost-effectiveness of surgical interventions for the management of osteoarthritis: a systematic review of the literature.

    PubMed

    Kamaruzaman, Hanin; Kinghorn, Philip; Oppong, Raymond

    2017-05-10

    The primary purpose of this study is to assess the existing evidence on the cost-effectiveness of surgical interventions for the management of knee and hip osteoarthritis by systematically reviewing published economic evaluation studies. A systematic review was conducted for the period 2004 to 2016. Electronic databases were searched to identify both trial and model based economic evaluation studies that evaluated surgical interventions for knee and hip osteoarthritis. A total of 23 studies met the inclusion criteria and an assessment of these studies showed that total knee arthroplasty (TKA), and total hip arthroplasty (THA) showed evidence of cost-effectiveness and improvement in quality of life of the patients when compared to non-operative and non-surgical procedures. On the other hand, even though delaying TKA and THA may lead to some cost savings in the short-run, the results from the study showed that this was not a cost-effective option. TKA and THA are cost-effective and should be recommended for the management of patients with end stage/severe knee and hip OA. However, there needs to be additional studies to assess the cost-effectiveness of other surgical interventions in order for definite conclusions to be reached.

  20. Soda consumption and risk of hip fractures in postmenopausal women in the Nurses’ Health Study1234

    PubMed Central

    Fung, Teresa T; Arasaratnam, Meredith H; Grodstein, Francine; Katz, Jeffrey N; Rosner, Bernard; Willett, Walter C; Feskanich, Diane

    2014-01-01

    Background: The frequency of soda consumption remains high in the United States. Soda consumption has been associated with poor bone health in children, but few studies have examined this relation in adults, and to our knowledge, no study has examined the relation of soda consumption with risk of hip fractures. Objective: We examined the association of soda, including specific types of soda, and risk of hip fracture in postmenopausal women. Design: An analysis was conducted in postmenopausal women from the Nurses’ Health Study cohort (n = 73,572). Diet was assessed at baseline by using a semiquantitative food-frequency questionnaire and updated approximately every 4 y. In ≤30 y of follow-up, we identified 1873 incident hip fractures. We computed RRs for hip fractures by the amount of soda consumption by using Cox proportional hazards models with adjustment for potential confounders. Results: In multivariable models, each additional serving of total soda per day was associated with a significant 14% increased risk of hip fracture (RR: 1.14; 95% CI: 1.06, 1.23). The attributable risk in our cohort for total soda consumption was 12.5%. Risk was significantly elevated in consumers of both regular soda (RR: 1.19; 95% CI: 1.02, 1.38) and diet soda (RR: 1.12; 95% CI: 1.03, 1.21) and also did not significantly differ between colas and noncolas or sodas with or without caffeine. The association between soda and hip fractures did not differ by body mass index or diagnosis of diabetes. Conclusion: Increased soda consumption of all types may be associated with increased risk of hip fracture in postmenopausal women; however, a clear mechanism was not apparent on the basis of these observational data. PMID:25099544

  1. Soda consumption and risk of hip fractures in postmenopausal women in the Nurses' Health Study.

    PubMed

    Fung, Teresa T; Arasaratnam, Meredith H; Grodstein, Francine; Katz, Jeffrey N; Rosner, Bernard; Willett, Walter C; Feskanich, Diane

    2014-09-01

    The frequency of soda consumption remains high in the United States. Soda consumption has been associated with poor bone health in children, but few studies have examined this relation in adults, and to our knowledge, no study has examined the relation of soda consumption with risk of hip fractures. We examined the association of soda, including specific types of soda, and risk of hip fracture in postmenopausal women. An analysis was conducted in postmenopausal women from the Nurses' Health Study cohort (n = 73,572). Diet was assessed at baseline by using a semiquantitative food-frequency questionnaire and updated approximately every 4 y. In ≤30 y of follow-up, we identified 1873 incident hip fractures. We computed RRs for hip fractures by the amount of soda consumption by using Cox proportional hazards models with adjustment for potential confounders. In multivariable models, each additional serving of total soda per day was associated with a significant 14% increased risk of hip fracture (RR: 1.14; 95% CI: 1.06, 1.23). The attributable risk in our cohort for total soda consumption was 12.5%. Risk was significantly elevated in consumers of both regular soda (RR: 1.19; 95% CI: 1.02, 1.38) and diet soda (RR: 1.12; 95% CI: 1.03, 1.21) and also did not significantly differ between colas and noncolas or sodas with or without caffeine. The association between soda and hip fractures did not differ by body mass index or diagnosis of diabetes. Increased soda consumption of all types may be associated with increased risk of hip fracture in postmenopausal women; however, a clear mechanism was not apparent on the basis of these observational data. © 2014 American Society for Nutrition.

  2. Higher fish intake is associated with a lower risk of hip fractures in Chinese men and women: a matched case-control study.

    PubMed

    Fan, Fan; Xue, Wen-Qiong; Wu, Bao-Hua; He, Ming-Guang; Xie, Hai-Li; Ouyang, Wei-Fu; Tu, Su-Lan; Chen, Yu-Ming

    2013-01-01

    Fish is rich in nutrients that are favorable to bone health, but limited data are available regarding the relationship between fish intake and hip fractures. Our study examined the association between habitual fish intake and risk of hip fractures. A case-control study was performed between June 2009 and June 2012 in Guangdong Province, China. Five hundred and eighty-one hip fracture incident cases, aged 55 to 80 years (mean: 71 years), were enrolled from four hospitals. 1∶1 matched controls by gender and age (±3 years) were also recruited from communities and hospitals. Face-to-face interviews were used to obtain habitual dietary intake and information on various covariates. Univariate conditional logistic regression analyses showed significantly dose-dependent inverse correlations between the risk of hip fractures and the intake of fresh-water fish, sea fish, mollusca, shellfish, and total fish in all of the subjects (p-trend: <0.001-0.016). After adjusting for covariates, the associations were slightly attenuated but remained significant for all (p-trend: <0.001-0.017) except for fresh-water fish (p = 0.553). The ORs (95%CI) of hip fractures for the highest (vs. lowest) quartile were 0.80 (0.48-1.31) for fresh-water fish, 0.31 (0.18-0.52) for sea fish, 0.55 (0.34-0.88) for mollusca and shellfish, and 0.47 (0.28-0.79) for total fish, respectively. Stratified and interaction analyses showed that the association was more significant in males than in females (p-interaction = 0.052). Higher intake of seafood is independently associated with lower risk of hip fractures in elderly Chinese. Increasing consumption of sea fish may benefit the prevention of hip fractures in this population.

  3. Analysis of rehabilitation activities within skilled nursing and inpatient rehabilitation facilities after hip replacement for acute hip fracture.

    PubMed

    Munin, Michael C; Putman, Koen; Hsieh, Ching-Hui; Smout, Randall J; Tian, Wenqiang; DeJong, Gerben; Horn, Susan D

    2010-07-01

    To characterize rehabilitation services in two types of postacute facilities in patients who underwent hip replacement following a hip fracture. Multisite prospective observational cohort from 6 freestanding skilled nursing facilities and 11 inpatient rehabilitation facilities. Patients (n = 218) with hip fracture who had either hemiarthroplasty or total hip arthroplasty followed by rehabilitation at skilled nursing facilities or inpatient rehabilitation facilities were enrolled. Using a point-of-care methodology, we recorded data from actual physical therapy and occupational therapy sessions completed including functional outcomes during the postacute admission. Onset time from surgical repair to rehabilitation admission was not significantly different between sites. Average skilled nursing facilities length of stay was 24.7 +/- 13.6 days, whereas inpatient rehabilitation facilities was 13.0 +/- 5.7 days (P < 0.01). Total hours of physical therapy and occupational therapy services per patient day were 1.2 in skilled nursing facilities and 2.0 in inpatient rehabilitation facilities. For weekdays only, these data changed to 1.6 in skilled nursing facilities and 2.6 hrs per patient in inpatient rehabilitation facilities (P < 0.01). Patients in inpatient rehabilitation facilities accrued more time for gait training and exercise in physical therapy, which was found to be 48% and 40% greater, respectively, through day 8. In occupational therapy, patients of inpatient rehabilitation facilities had more time allocated to lower body dressing and transfers. Significant differences in rehabilitation activities were observed, and intensity was notably different within the first 8 therapy days even though baseline demographics and medical complexity were comparable across facility types. Our data suggest that after more complex hip replacement surgery, hip fracture patients can tolerate more intensive therapy earlier within the rehabilitation program.

  4. Radiographic Underestimation of In Vivo Cup Coverage Provided by Total Hip Arthroplasty for Dysplasia.

    PubMed

    Nie, Yong; Wang, HaoYang; Huang, ZeYu; Shen, Bin; Kraus, Virginia Byers; Zhou, Zongke

    2018-01-01

    The accuracy of using 2-dimensional anteroposterior pelvic radiography to assess acetabular cup coverage among patients with developmental dysplasia of the hip after total hip arthroplasty (THA) remains unclear in retrospective clinical studies. A group of 20 patients with developmental dysplasia of the hip (20 hips) underwent cementless THA. During surgery but after acetabular reconstruction, bone wax was pressed onto the uncovered surface of the acetabular cup. A surface model of the bone wax was generated with 3-dimensional scanning. The percentage of the acetabular cup that was covered by intact host acetabular bone in vivo was calculated with modeling software. Acetabular cup coverage also was determined from a postoperative supine anteroposterior pelvic radiograph. The height of the hip center (distance from the center of the femoral head perpendicular to the inter-teardrop line) also was determined from radiographs. Radiographic cup coverage was a mean of 6.93% (SD, 2.47%) lower than in vivo cup coverage for these 20 patients with developmental dysplasia of the hip (P<.001). However, both methods yielded highly correlated measurements for cup coverage (Pearson r=0.761, P<.001). The size of the acetabular cup (P=.001) but not the position of the hip center (high vs normal) was significantly associated with the difference between radiographic and in vivo cup coverage. Two-dimensional radiographically determined cup coverage conservatively reflects in vivo cup coverage and remains an important index (taking 7% underestimation errors and the effect of greater underestimation of larger cup size into account) for assessing the stability of the cup and monitoring for adequate ingrowth of bone. [Orthopedics. 2018; 41(1):e46-e51.]. Copyright 2017, SLACK Incorporated.

  5. Full kinetic chain manual and manipulative therapy plus exercise compared with targeted manual and manipulative therapy plus exercise for symptomatic osteoarthritis of the hip: a randomized controlled trial.

    PubMed

    Brantingham, James W; Parkin-Smith, Gregory; Cassa, Tammy Kay; Globe, Gary A; Globe, Denise; Pollard, Henry; deLuca, Katie; Jensen, Muffit; Mayer, Stephan; Korporaal, Charmaine

    2012-02-01

    To determine the short-term effectiveness of full kinematic chain manual and manipulative therapy (MMT) plus exercise compared with targeted hip MMT plus exercise for symptomatic mild to moderate hip osteoarthritis (OA). Parallel-group randomized trial with 3-month follow-up. Two chiropractic outpatient teaching clinics. Convenience sample of eligible participants (N=111) with symptomatic hip OA were consented and randomly allocated to receive either the experimental or comparison treatment, respectively. Participants in the experimental group received full kinematic chain MMT plus exercise while those in the comparison group received targeted hip MMT plus exercise. Participants in both groups received 9 treatments over a 5-week period. Western Ontario and McMasters Osteoarthritis Index (WOMAC), Harris hip score (HHS), and Overall Therapy Effectiveness, alongside estimation of clinically meaningful outcomes. Total dropout was 9% (n=10) with 7% of total data missing, replaced using a multiple imputation method. No statistically significant differences were found between the 2 groups for any of the outcome measures (analysis of covariance, P=.45 and P=.79 for the WOMAC and HHS, respectively). There were no statistically significant differences in the primary or secondary outcome scores when comparing full kinematic chain MMT plus exercise with targeted hip MMT plus exercise for mild to moderate symptomatic hip OA. Consequently, the nonsignificant findings suggest that there would also be no clinically meaningful difference between the 2 groups. The results of this study provides guidance to musculoskeletal practitioners who regularly use MMT that the full kinematic chain approach does not appear to have any benefit over targeted treatment. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  6. The risk of venous thromboembolism with aspirin compared to anticoagulants after hip and knee arthroplasty.

    PubMed

    Chu, Janet N; Maselli, Judith; Auerbach, Andrew D; Fang, Margaret C

    2017-07-01

    Recent guidelines include aspirin as an option to prevent venous thromboembolism (VTE) in selected patients undergoing hip or knee replacement surgery. However, the efficacy of aspirin after arthroplasty has not been well-defined, particularly in more contemporary patient populations. We compared rates of post-operative VTE between patients who received aspirin-only versus anticoagulants after hip or knee arthroplasty, using data from a large US-based administrative database. We conducted a retrospective cohort study of 231,780 adults who underwent total knee arthroplasty and 110,621 who underwent total hip arthroplasty in 2009-2012 and who received pharmacologic VTE prophylaxis (aspirin or anticoagulant) within the first 7days after surgery. We compared the risk of post-operative VTE between patients receiving aspirin-only vs. anticoagulants, controlling for clinical and hospital characteristics using multivariable logistic regression with propensity score adjustment. Aspirin-only prophylaxis was administered to 7.5% of patients after knee arthroplasty and 8.0% after hip arthroplasty. Post-operative VTE was diagnosed in 2217 (0.96%) patients after knee arthroplasty and 454 (0.41%) after hip arthroplasty. Compared to anticoagulants, aspirin was not associated with a higher risk for post-operative VTE either after knee arthroplasty (adjusted odds ratio and 95% confidence interval [OR] 0.34 [0.24-0.48]) or hip arthroplasty (OR 0.82 [0.45-1.51]). Aspirin was uncommonly administered as the sole prophylactic agent after hip or knee arthroplasty in this study. However, patients who received aspirin-only had similar rates of post-operative VTE compared to patients who received anticoagulants. Further research should focus on distinguishing which patients benefit more from anticoagulants versus aspirin after arthroplasty. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. High complication rate in reconstruction of Paprosky type IIIa acetabular defects using an oblong implant with modular side plates and a hook.

    PubMed

    Babis, G C; Sakellariou, V I; Chatziantoniou, A N; Soucacos, P N; Megas, P

    2011-12-01

    We report the results of 62 hips in 62 patients (17 males, 45 females) with mean age of 62.4 years (37 to 81), who underwent revision of the acetabular component of a total hip replacement due to aseptic loosening between May 2003 and November 2007. All hips had a Paprosky type IIIa acetabular defect. Acetabular revision was undertaken using a Procotyl E cementless oblong implant with modular side plates and a hook combined with impaction allografting. At a mean follow-up of 60.5 months (36 to 94) with no patients lost to follow-up and one died due to unrelated illness, the complication rate was 38.7%. Complications included aseptic loosening (19 hips), deep infection (3 hips), broken hook and side plate (one hip) and a femoral nerve palsy (one hip). Further revision of the acetabular component was required in 18 hips (29.0%) and a further four hips (6.4%) are currently loose and awaiting revision. We observed unacceptably high rates of complication and failure in our group of patients and cannot recommend this implant or technique.

  8. Intra- and extra-articular planes of reference for use in total hip arthroplasty: a preliminary study.

    PubMed

    Hausselle, Jerome; Moreau, Pierre Etienne; Wessely, Loic; de Thomasson, Emmanuel; Assi, Ayman; Parratte, Sebastien; Essig, Jerome; Skalli, Wafa

    2012-08-01

    Acetabular component malalignment in total hip arthroplasty can lead to potential complications such as dislocation, component impingement and excessive wear. Computer-assisted orthopaedic surgery systems generally use the anterior pelvic plane (APP). Our aim was to investigate the reliability of anatomical landmarks accessible during surgery and to define new potential planes of reference. Three types of palpations were performed: virtual, on dry bones and on two cadaveric specimens. Four landmarks were selected, the reproducibility of their positioning ranging from 0.9 to 2.3 mm. We then defined five planes and tested them during palpations on two cadaveric specimens. Two planes produced a mean orientation error of 5.0° [standard deviation (SD 3.3°)] and 5.6° (SD 2.7°). Even if further studies are needed to test the reliability of such planes on a larger scale in vivo during surgery, these results demonstrated the feasibility of defining a new plane of reference as an alternative to the APP.

  9. The effectiveness and safety of aminocaproic acid for reducing blood loss in total knee and hip arthroplasty: A meta-analysis.

    PubMed

    Dong, Qiang; Zhang, Yinguang; Sun, Xiang; Hu, Fangke

    2018-04-01

    This meta-analysis aimed to evaluate the safety and efficacy of aminocaproic acid in total knee arthroplasty (TKA) and total hip arthroplasty (THA). The electronic databases include PubMed, Medline, Embase, Web of Science and the Cochrane Library from inception to January, 2018. Two reviewers abstracted total blood loss, hemoglobin drop, transfusion requirements, and postoperative complications. Data were using fixed-effects or random-effects models with weighted mean differences and risk difference for continuous and dichotomous variables, respectively. STATA 14.0 was used to perform the meta-analysis. Six studies encompassing 756 participants were retrieved for this meta-analysis. Our study indicated that intravenous aminocaproic acid was associated with a significantly reduction in total blood loss, hemoglobin drop and need for transfusion. Additionally, no increased risk of thromboembolic events were identified. Based on the present meta-analysis, intravenous aminocaproic acid is effective and safe in total knee and hip arthroplasty without increasing the incidence of thromboembolic events. Further studies should focus on the comparison of aminocaproic acid and TXA in arthroplasties. Copyright © 2018 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  10. Tribocorrosion behavior of CoCrMo alloy for hip prosthesis as a function of loads: a comparison between two testing systems

    PubMed Central

    Mathew, M.T.; Runa, M.J.; Laurent, M.; Jacobs, J.J.; Rocha, L.A.; Wimmer, M.A.

    2011-01-01

    Metal-on-metal (MOM) hip prosthesis bearings have enjoyed renewed popularity, but concerns remain with wear debris and metal ion release causing a negative response in the surrounding tissues. Further understanding into the wear and corrosion mechanisms occurring in MOM hips is therefore essential. The purpose of this study was to evaluate the tribocorrosion behaviour, or interplay between corrosion and wear, of a low-carbon CoCrMo alloy as a function of loading. The tribocorrosion tests were performed using two tribometer configurations. In the first configuration, “System A”, a linearly reciprocating alumina ball slid against the flat metal immersed in a phosphate buffer solution (PBS). In the second configuration, “System B”, the flat end of a cylindrical metal pin was pressed against an alumina ball that oscillated rotationally, using bovine calf serum (BCS) as the lubricant and electrolyte. System B was custom-built to emulate in vivo conditions. The tribocorrosion tests were performed under potentiostatic conditions at -0.345V, with a sliding duration of 1800 seconds and a frequency of 1Hz. In System A the applied loads were 0.05, 0.5, and 1N (138, 296 and 373MPa, respectively) and in System B were 16, 32, and 64N (474, 597, and 752MPa, respectively). Electrochemical impedance spectroscopy (EIS) and polarization resistance were estimated. The total mass loss (Kwc) in the CoCrMo was determined. The mass loss due to wear (Kw) and that due to corrosion (Kc) were determined. The dominant wear regime for the CoCrMo alloy subjected to sliding changes from wear-corrosion to mechanical wear as the contact stress increases. An attempt was made to compare both system, in their tribochemical responses and formulate some insights in the total degradation processes. Our results also suggest that the proteins in the serum lubricant assist in the generation of a protective layer against corrosion during sliding. The study highlights the need of adequate methodology/guidelines to compare the results from different test systems and translating in solving the practical problems. PMID:21921971

  11. Incidence and Location of Pain in Young, Active Patients Following Hip Arthroplasty.

    PubMed

    Nam, Denis; Nunley, Ryan M; Sauber, Timothy J; Johnson, Staci R; Brooks, Peter J; Barrack, Robert L

    2015-11-01

    Persistent pain following hip arthroplasty remains a concern, especially in young, active patients. Four hundred twenty patients less than 60 years of age with a pre-symptomatic UCLA score ≥ 6 (196 total hip arthroplasty [THA]; 224 surface replacement arthroplasty [SRA]) completed a pain-drawing questionnaire investigating the location, severity, and frequency of pain around the hip. At a mean of 2.9 years of follow-up, 40% reported pain in at least one location around the hip. There was no difference in the incidence of groin pain between SRA and THA patients (32% vs. 29%, P=0.6), but THA patients had a greater incidence of anterior (25% vs. 8%, P<0.001) and lateral (20% vs. 10%, P=0.01) thigh pain. A high percentage of young, active patients experience persistent pain following hip arthroplasty. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Incidence of perioperative complications in total hip and knee arthroplasty in patients with Parkinson disease.

    PubMed

    Sharma, Tankamani; Hönle, Wolfgang; Handschu, René; Adler, Werner; Goyal, Tarun; Schuh, Alexander

    2018-06-01

    The aim of this study is to evaluate the difference in perioperative complication rate in total hip, bipolar hemiarthroplasties and total knee arthroplasty in patients with Parkinson disease in trauma and elective surgery in our Musculoskeletal Center during a period of 10 years. Between 2006 and 2016, 45 bipolar hemiarthroplasties in trauma surgery, 15 total knee and 19 total hip arthroplasties in patients with Parkinson's disease were performed. We divided the patients in two groups. Group I included trauma cases (45) and group II elective surgery cases (34). Complications were documented and divided into local minor and major complications and general minor and major complications. Fisher's exact test was used for statistical evaluation. In both groups, there was one local major complication (p > 0.05): In group I, there was one case of loosening of a K-wire which was removed operatively. In group II, there was one severe intraarticular bleeding requiring puncture of the hematoma. In group I, there were 38 general complications; in group II, there were 17 general complications. There was no statistical difference in complication rate (p > 0.05). Total hip arthroplasty, bipolar hemiarthroplasties and knee arthroplasty in patients with Parkinson disease is possible in elective and trauma surgery. Complication rate is higher in comparison with patients not suffering from Parkinson disease, but there is no difference in complication rate in elective and trauma surgery. Nevertheless, early perioperative neurological consultation in patients with Parkinson disease is recommended to minimize complications and improve early outcomes after arthroplasty.

  13. Primary vs Conversion Total Hip Arthroplasty: A Cost Analysis

    PubMed Central

    Chin, Garwin; Wright, David J.; Snir, Nimrod; Schwarzkopf, Ran

    2018-01-01

    Introduction Increasing hip fracture incidence in the United States is leading to higher occurrences of conversion total hip arthroplasty (THA) for failed surgical treatment of the hip. In spite of studies showing higher complication rates in conversion THA, the Centers for Medicare and Medicaid services currently bundles conversion and primary THA under the same diagnosis-related group. We examined the cost of treatment of conversion THA compared with primary THA. Our hypothesis is that conversion THA will have higher cost and resource use than primary THA. Methods Fifty-one consecutive conversion THA patients (Current Procedure Terminology code 27132) and 105 matched primary THA patients (Current Procedure Terminology code 27130) were included in this study. The natural log-transformed costs for conversion and primary THA were compared using regression analysis. Age, gender, body mass index, American Society of Anesthesiologist, Charlson comorbidity score, and smoker status were controlled in the analysis. Conversion THA subgroups formed based on etiology were compared using analysis of variance analysis. Results Conversion and primary THAs were determined to be significantly different (P < .05) and greater in the following costs: hospital operating direct cost (29.2% greater), hospital operating total cost (28.8% greater), direct hospital cost (24.7% greater), and total hospital cost (26.4% greater). Conclusions Based on greater hospital operating direct cost, hospital operating total cost, direct hospital cost, and total hospital cost, conversion THA has significantly greater cost and resource use than primary THA. In order to prevent disincentives for treating these complex surgical patients, reclassification of conversion THA is needed, as they do not fit together with primary THA. PMID:26387923

  14. Trochantoplasty for Total Hip Arthroplasty in Patients With Coxa Vara Deformity.

    PubMed

    Yoo, Jun-Il; Parvizi, Javad; Song, Ji-Ung; Ha, Yong-Chan; Lee, Young-Kyun; Koo, Kyung-Hoi

    2017-07-01

    In total hip arthroplasty (THA) of hips with coxa vara, the femoral stems might be inserted in a varus alignment. To avoid varus insertion, we designed a technique, which we termed "trochantoplasty." In this procedure, the medial half of the greater trochanter was removed during THA. We evaluated 30 patients (31 hips) who had coxa vara deformity and underwent THA using trochantoplasty at the mean follow-up of 5 years (range, 3-9 years). All stems were inserted in the neutral position. One Vancouver type 1 periprosthetic femoral fracture occurred after a fall at postoperative 2 months. At the latest follow-up, the mean power of abductor was 4.3 (range, 3-5). Four patients had moderate limp whereas 26 patients had slight limp. The abduction at 90° flexion ranged from 15° to 45° (mean, 35°). There was no revision. All prostheses had bone-ingrown stability without any detectable wear or osteolysis. The mean Harris hip score was improved from 66.9 to 89.4 points. Trochantoplasty can be used to avoid varus insertion of the femoral stem while performing THA in patients with coxa vara deformity without compromising the abductor mechanism. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. A specific inpatient aquatic physiotherapy program improves strength after total hip or knee replacement surgery: a randomized controlled trial.

    PubMed

    Rahmann, Ann E; Brauer, Sandra G; Nitz, Jennifer C

    2009-05-01

    To evaluate the effect of inpatient aquatic physiotherapy in addition to usual ward physiotherapy on the recovery of strength, function, and gait speed after total hip or knee replacement surgery. Pragmatic randomized controlled trial with blinded 6-month follow-up. Acute-care private hospital. People (n=65) undergoing primary hip or knee arthroplasty (average age, 69.6+/-8.2y; 30 men). Participants were randomly assigned to receive supplementary inpatient physiotherapy, beginning on day 4: aquatic physiotherapy, nonspecific water exercise, or additional ward physiotherapy. Strength, gait speed, and functional ability at day 14. At day 14, hip abductor strength was significantly greater after aquatic physiotherapy intervention than additional ward treatment (P=.001) or water exercise (P=.011). No other outcome measures were significantly different at any time point in the trial, but relative differences favored the aquatic physiotherapy intervention at day 14. No adverse events occurred with early aquatic intervention. A specific inpatient aquatic physiotherapy program has a positive effect on early recovery of hip strength after joint replacement surgery. Further studies are required to confirm these findings. Our research indicates that aquatic physiotherapy can be safely considered in this early postoperative phase.

  16. Kinematic alignment technique for total hip and knee arthroplasty

    PubMed Central

    Rivière, Charles; Lazic, Stefan; Villet, Loïc; Wiart, Yann; Allwood, Sarah Muirhead; Cobb, Justin

    2018-01-01

    Conventional techniques for hip and knee arthroplasty have led to good long-term clinical outcomes, but complications remain despite better surgical precision and improvements in implant design and quality. Technological improvements and a better understanding of joint kinematics have facilitated the progression to ‘personalized’ implant positioning (kinematic alignment) for total hip (THA) and knee (TKA) arthroplasty, the true value of which remains to be determined. By achieving a true knee resurfacing, the kinematic alignment (KA) technique for TKA aims at aligning the components with the physiological kinematic axes of the knee and restoring the constitutional tibio-femoral joint line frontal and axial orientation and soft-tissue laxity. The KA technique for THA aims at restoring the native ‘combined femoro-acetabular anteversion’ and the hip’s centre of rotation, and occasionally adjusting the cup position and design based on the assessment of the individual spine-hip relation. The key element for optimal prosthetic joint kinematics (hip or knee) is to reproduce the femoral anatomy. The transverse acetabular ligament (TAL) is the reference landmark to adjust the cup position. Cite this article: EFORT Open Rev 2018;3:98-105. DOI: 10.1302/2058-5241.3.170022 PMID:29657851

  17. Possible Vascular Injury Due to Screw Eccentricity in Minimally Invasive Total Hip Arthroplasty.

    PubMed

    Singh, Nishant Kumar; Rai, Sanjay Kumar; Rastogi, Amit

    2017-01-01

    Vascular injury during minimally invasive total hip arthroplasty (THA) is uncommon, yet a well-recognized and serious issue. It emerges because of non-visibility of vascular structures proximal to the pelvic bone during reaming, drilling holes, and fixing of screws. Numerous studies have found that screw fixation during cementless THA is beneficial for the initial stability of cup; yet, no anatomical guidelines support angular eccentric screw fixation. In this study, we obtained the pelvic arterial-phase computed tomographic data of thirty eight humans and reconstructed the three-dimensional models of osseous and vessel structures. We performed the surgical simulation to fix these structures with cementless cups and screws with angular eccentricities. The effect of screw eccentricities (angular eccentricities of ±17° and ±34°) on the vascular injury was determined. Measurement between screw and adjoining vessels was performed and analyzed statistically to ascertain a comparative risk study for blood vessels that are not visible during surgery. Authors similarly discussed the significant absence of appreciation of quadrant systems proposed by Wasielewski et al . on eccentric screws. Adjustment of quadrant systems provided by Wasielewski et al . is required for acetabular implants with eccentric holes for fixation of acetabular screws.

  18. The current status and future prospects of computer-assisted hip surgery.

    PubMed

    Inaba, Yutaka; Kobayashi, Naomi; Ike, Hiroyuki; Kubota, So; Saito, Tomoyuki

    2016-03-01

    The advances in computer assistance technology have allowed detailed three-dimensional preoperative planning and simulation of preoperative plans. The use of a navigation system as an intraoperative assistance tool allows more accurate execution of the preoperative plan, compared to manual operation without assistance of the navigation system. In total hip arthroplasty using CT-based navigation, three-dimensional preoperative planning with computer software allows the surgeon to determine the optimal angle of implant placement at which implant impingement is unlikely to occur in the range of hip joint motion necessary for daily activities of living, and to determine the amount of three-dimensional correction for leg length and offset. With the use of computer navigation for intraoperative assistance, the preoperative plan can be precisely executed. In hip osteotomy using CT-based navigation, the navigation allows three-dimensional preoperative planning, intraoperative confirmation of osteotomy sites, safe performance of osteotomy even under poor visual conditions, and a reduction in exposure doses from intraoperative fluoroscopy. Positions of the tips of chisels can be displayed on the computer monitor during surgery in real time, and staff other than the operator can also be aware of the progress of surgery. Thus, computer navigation also has an educational value. On the other hand, its limitations include the need for placement of trackers, increased radiation exposure from preoperative CT scans, and prolonged operative time. Moreover, because the position of a bone fragment cannot be traced after osteotomy, methods to find its precise position after its movement need to be developed. Despite the need to develop methods for the postoperative evaluation of accuracy for osteotomy, further application and development of these systems are expected in the future. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  19. Outcomes of elderly hip fracture patients in the Swiss healthcare system: A survey prior to the implementation of DRGs and prior to the implementation ofa Geriatric Fracture Centre.

    PubMed

    Pretto, Manuela; Spirig, Rebecca; Kaelin, Raphael; Muri-John, Vanessa; Kressig, Reto W; Suhm, Norbert

    2010-08-24

    PROBLEM AND QUESTIONS: The consequences for elderly patients with hip fractures are well known. In Switzerland, the introduction of diagnosis related groups (DRG) will bring additional challenges. New models of care, such as Geriatric Fracture Centres (GFC), may be the key to minimising negative outcomes. This study documents outcomes of hip fracture patients in the Swiss healthcare system, for use as baseline data prior to DRG- and GFC-implementation, and compares them to results reported in the literature, for example by Cooper (1997). This was a prospective cohort quality assurance survey with a one-year follow-up. Outcomes were mortality, living situation, required support and mobility. All patients 65 years of age or older with a proximal femoral fracture were included. Data were analysed by descriptive and interferential statistics. From 272 patients, 70% were community dwelling pre-fracture. Overall, one-year mortality was 22%. Pre-fracture community dwelling patients had better outcomes than nursing home patients with a one-year mortality rate of 12%. A total of 83% of pre-fracture community dwelling patients still lived in the community after one year but more needed help with activities of daily living (ADL) or mobility. Patients with dementia, ADL- and mobility dependency pre-fracture were significantly more at risk for being newly admitted to a nursing home. Our results reflect the clinical reality of the hip fracture population in Switzerland. Results one year after fracture were comparable to study findings in different health care systems. Our findings provide important baseline data prior to the implementation of DRG and GFC.

  20. Mixed qualitative and quantitative approach for validating an information booklet before total hip arthroplasty.

    PubMed

    Chabaud, Aurore; Eschalier, Bénédicte; Zullian, Myriam; Plan-Paquet, Anne; Aubreton, Sylvie; Saragaglia, Dominique; Descamps, Stéphane; Coudeyre, Emmanuel

    2018-05-01

    Providing patients with validated information before total hip arthroplasty may help lessen discrepancies between patients' expectations and the surgical result. This study sought to validate an information booklet for candidates for hip arthroplasty by using a mixed qualitative and quantitative approach based on a panel of patients and a sample of healthcare professionals. We developed a booklet in accordance with the standard methods and then conducted focus groups to collect the opinions of a sample of multidisciplinary experts involved in the care of patients with hip osteoarthritis. The number of focus groups and experts was determined according to the data saturation principle. A panel of patients awaiting hip arthroplasty or those in the immediate post-operative period assessed the booklet with self-reporting questionnaires (knowledge, beliefs, and expectations) and semi-structured interviews. All experts and both patient groups validated the booklet in terms of content and presentation. Semi-structured interviews were uninformative, especially for post-operative patients. Reading the booklet significantly (P<0.001) improved the knowledge scores in both groups, with no intergroup differences, but did not affect beliefs in either patient group. Only pre-operative patients significantly changed their expectations. Our mixed qualitative and quantitative approach allowed us to validate a booklet for patients awaiting hip arthroplasty, taking into account the opinions of both patients and healthcare professionals. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  1. A simple technique to strengthen the initial and mid-term to long-term stability of the cup during total hip arthroplasty in developmental dysplasia of the hip.

    PubMed

    Guan, Mingqiang; Zhou, Guanming; Li, Xue

    2018-04-01

    To assess the effects of a technique of cup blocking screws combined with impaction bone grafting during total hip arthroplasty (THA) for patients with developmental dysplasia of the hip (DDH). From August 2011 to July 2015, 53 patients (59 hips) with DDH in our hospital were treated with THA using the technique of cup blocking screws combined with impaction particulate bone grafting. These patients were prospectively followed, and the clinical and imaging results were collected. Harris hip score (HHS) was raised from 41.24 before surgery to 91.49 at the latest follow-up (p less than 0.001). Length discrepancy (LLD) was reduced from 28.97 mm before surgery to 6.08 mm after surgery (p less than 0.001). No loosening of the cup was detected at the last follow-up. The differences were insignificant in cup inclination and rate of cup coverage among the 3 groups of Crowe type II, type III, and type IV DDH (p greater than 0.05). The technique of cup blocking screws combined with impaction particulate bone grafting is simple and reliable, and it not only simplifies the attainment of initial stability, but also strengthens the mid-term to long-term stability during THA in DDH.

  2. Treatment Challenges of Prosthetic Hip Infection with Associated Iliacus Muscle Abscess: Report of 5 Cases and Literature Review.

    PubMed

    Lawrenz, Joshua M; Mesko, Nathan W; Higuera, Carlos A; Molloy, Robert M; Simpfendorfer, Claus; Babic, Maja

    2017-01-01

    Prosthetic joint infection is an unfortunate though well-recognized complication of total joint arthroplasty. An iliacus and/or iliopsoas muscle abscess is a rarely documented presentation of hip prosthetic joint infection. It is thought an unrecognized retroperitoneal nidus of infection can be a source of continual seeding of the prosthetic hip joint, prolonging attempts to eradicate infection despite aggressive debridement and explant attempts. The current study presents five cases demonstrating this clinical scenario, and discusses various treatment challenges. In each case we report the patient's clinical history, pertinent imaging, management and outcome. Diagnosis of the iliacus muscle abscess was made using computed tomography imaging. In brief, the mean number of total drainage procedures (open and percutaneous) per patient was 4.2, and outcomes consisted of one patient with a hip girdlestone, two patients with delayed revisions, and two patients with retained prosthesis. All patients ended with functional pain and on oral antibiotic suppression with an average follow up of 18 months. This article highlights an iliacus muscle abscess as an unrecognized source of infection to a prosthetic hip. It demonstrates resilience to standard treatment protocols for prosthetic hip infection, and is associated with poor patient outcomes. Aggressive surgical debridement appears to remain critical to treatment success, and early retroperitoneal debridement of the abscess should be considered.

  3. Press-fit versus threaded acetabular cups in total hip arthroplasty: Functional and radiological results after five years.

    PubMed

    Ellenrieder, Martin; Bader, Rainer; Bergschmidt, Philipp; Mittelmeier, Wolfram

    2016-03-01

    Prospectively the outcome after total hip replacement with a new threaded acetabular cup design was compared to an established press-fit cup. After 1, 2 and 5 years, the 36-item Short Form Health Survey, Western Ontario and McMaster University Osteoarthritis Index and Harris Hip Score revealed no significant differences between the two groups (each group: n=42 patients), except for a higher Harris Hip Score in the threaded cup group after five years (p=0.02). After five years, one threaded cup had a mild radiolucent line without further signs of loosening. All other cups of both groups (98.6%) showed a full osseous integration. The cup inclination angle ranged from 41-58° (threaded cups) to 39-77° (press-fit cups). The new threaded cup provides equivalent clinical outcomes and osseous integration but more precise implant positioning compared to the press-fit design. No complications typically ascribed to threaded cups (acetabular fractures, bone resorption, nerve impairment) occurred.

  4. Management bone loss of the proximal femur in revision hip arthroplasty: Update on reconstructive options

    PubMed Central

    Sakellariou, Vasileios I; Babis, George C

    2014-01-01

    The number of revision total hip arthroplasties is expected to rise as the indications for arthroplasty will expand due to the aging population. The prevalence of extensive proximal femoral bone loss is expected to increase subsequently. The etiology of bone loss from the proximal femur after total hip arthroplasty is multifactorial. Stress shielding, massive osteolysis, extensive loosening and history of multiple surgeries consist the most common etiologies. Reconstruction of extensive bone loss of the proximal femur during a revision hip arthroplasty is a major challenge for even the most experienced orthopaedic surgeon. The amount of femoral bone loss and the bone quality of the remaining metaphyseal and diaphyseal bone dictate the selection of appropriate reconstructive option. These include the use of impaction allografting, distal press-fit fixation, allograft-prosthesis composites and tumor megaprostheses. This review article is a concise review of the current literature and provides an algorithmic approach for reconstruction of different types of proximal femoral bone defects. PMID:25405090

  5. Magnification of digital hip radiographs differs between clinical workplaces.

    PubMed

    Hornová, Jana; Růžička, Pavel; Hrubina, Maroš; Šťastný, Eduard; Košková, Andrea; Fulín, Petr; Gallo, Jiří; Daniel, Matej

    2017-01-01

    Preoperative planning for total hip arthroplasty includes templating on anteroposterior radiographs. It is necessary to consider radiographic magnification in order to scale templates accurately. Studies dealing with hip templating report different values of radiographic magnification. It is not clear if the observed difference in magnification between the studies is caused by variability in studied groups, methodology or instrumentation. We hypothesize that there is a difference in magnification between clinical workplaces. Within this study, radiographic magnification was estimated on 337 radiographs of patients after total hip surgery from five orthopaedic departments in the Czech Republic. Magnification was determined for each patient as a ratio between diameter of implanted femoral head measured on radiogram and its true size. One-way ANOVA revealed significant differences in magnification between workplaces (F(4,332) = 132, p≤0.001). These results suggest that radiographic magnification depends on the workplace where it is taken or more precisely on radiographic device. It indicates potential limits in generalizability of results of studies dealing with preoperative planning accuracy to other institutions.

  6. Assessment of malnutrition in hip fracture patients: effects on surgical delay, hospital stay and mortality.

    PubMed

    Symeonidis, Panagiotis D; Clark, David

    2006-08-01

    The importance of malnutrition in elderly hip fracture patients has long been recognised. All patients operated upon for a hip fracture over a five-year period were assessed according to two nutritional markers : a) serum albumin levels and b) peripheral blood total lymphocyte count. Patients were subdivided into groups according to the four possible combinations of these results. Outcomes according to four clinical outcome parameters were validated: a) waiting time to operation b) length of hospitalisation, c) in-hospital mortality, and d) one-year postoperative mortality. Significant differences were found between malnourished patients and those with normal laboratory values with regard to surgical delay and one year postoperative mortality. Malnourished patients were also more likely to be hospitalised longer than a month and to die during their hospital stay, but the difference was not significant. The combination of serum albumin level and total lymphocyte count can be used as an independent prognostic factor in hip fracture patients.

  7. Compact Hip-Force Sensor for a Gait-Assistance Exoskeleton System.

    PubMed

    Choi, Hyundo; Seo, Keehong; Hyung, Seungyong; Shim, Youngbo; Lim, Soo-Chul

    2018-02-13

    In this paper, we propose a compact force sensor system for a hip-mounted exoskeleton for seniors with difficulties in walking due to muscle weakness. It senses and monitors the delivered force and power of the exoskeleton for motion control and taking urgent safety action. Two FSR (force-sensitive resistors) sensors are used to measure the assistance force when the user is walking. The sensor system directly measures the interaction force between the exoskeleton and the lower limb of the user instead of a previously reported force-sensing method, which estimated the hip assistance force from the current of the motor and lookup tables. Furthermore, the sensor system has the advantage of generating torque in the walking-assistant actuator based on directly measuring the hip-assistance force. Thus, the gait-assistance exoskeleton system can control the delivered power and torque to the user. The force sensing structure is designed to decouple the force caused by hip motion from other directional forces to the sensor so as to only measure that force. We confirmed that the hip-assistance force could be measured with the proposed prototype compact force sensor attached to a thigh frame through an experiment with a real system.

  8. Compact Hip-Force Sensor for a Gait-Assistance Exoskeleton System

    PubMed Central

    Choi, Hyundo; Seo, Keehong; Hyung, Seungyong; Shim, Youngbo; Lim, Soo-Chul

    2018-01-01

    In this paper, we propose a compact force sensor system for a hip-mounted exoskeleton for seniors with difficulties in walking due to muscle weakness. It senses and monitors the delivered force and power of the exoskeleton for motion control and taking urgent safety action. Two FSR (force-sensitive resistors) sensors are used to measure the assistance force when the user is walking. The sensor system directly measures the interaction force between the exoskeleton and the lower limb of the user instead of a previously reported force-sensing method, which estimated the hip assistance force from the current of the motor and lookup tables. Furthermore, the sensor system has the advantage of generating torque in the walking-assistant actuator based on directly measuring the hip-assistance force. Thus, the gait-assistance exoskeleton system can control the delivered power and torque to the user. The force sensing structure is designed to decouple the force caused by hip motion from other directional forces to the sensor so as to only measure that force. We confirmed that the hip-assistance force could be measured with the proposed prototype compact force sensor attached to a thigh frame through an experiment with a real system. PMID:29438300

  9. Hospital market concentration, pricing, and profitability in orthopedic surgery and interventional cardiology.

    PubMed

    Robinson, James C

    2011-06-01

    To examine the association between hospital market concentration and pricing. Hospitals have been merging into systems that potentially wield bargaining power over private health insurers. Concern is growing among policy makers that these systems may respond to provisions of the 2010 health reform legislation by further increasing consolidation and prices. Multivariate statistical methods were used to evaluate the association between hospital market concentration, prices, and profits (contribution margins) for commercially insured patients admitted for any of 6 major cardiac and orthopedic surgery procedures, adjusting for characteristics of the patient (diagnoses, comorbidities,complications) and of the hospital (size, patient volume, teaching status). Data were obtained on 11,330 patients treated in 61 hospitals in 27 markets across 8 states in 2008. Hospital prices for patients in concentrated markets were higher than hospital prices for otherwise-comparable patients in competitive markets by 25.1% for coronary angioplasty, 13.0%for cardiac rhythm management (CRM) device insertion, 19.2% for total knee replacement, 24.1%for total hip replacement, 19.3% for lumbar spine fusion, and 22.7% for cervical spine fusion (P <.05). Contribution margins were higher in concentrated than in competitive hospital markets by $5259 for angioplasty, $3417 for CRM device insertion, $4123 for total knee replacement, $5889 for total hip replacement, $7931 for lumbar spine fusion, and $4663 for cervical spine fusion (P <.05). Hospitals in concentrated markets charge significantly higher prices and earn significantly higher margins from private insurers than do hospitals in competitive markets.

  10. Effectiveness of rehabilitation after a total hip arthroplasty: a protocol for an observational study for the comparison of usual care in the Netherlands versus Germany.

    PubMed

    Seeber, Gesine H; Wijnen, Annet; Lazovic, Djordje; Bulstra, Sjoerd K; Dietz, Günter; van Lingen, Christiaan P; Stevens, Martin

    2017-08-11

    Osteoarthritis is the most common joint disorder worldwide. Total hip arthroplasty (THA) is considered one of the most effective treatments for end-stage hip osteoarthritis. The number of THAs is expected to increase dramatically in the coming decades. Usual postoperative rehabilitation after primary THA differs between the German and the Dutch system. In the Netherlands, patients undergo fast-track surgery and are discharged into their home environment within a few days without receiving any aftercare. In Germany, patients stay in the hospital for about 12 days before being transferred to a rehabilitation centre for a period of 3 weeks. The superficially more cost-effective Dutch system of usual care after THA is judged critically in both countries due to suboptimal rehabilitation outcomes. The aim of this study is therefore to compare the Dutch with the German usual care rehabilitation after primary THA. It is hypothesised that the German procedure is more effective in terms of functional outcomes and patient satisfaction than the Dutch procedure and that in the long run the German approach is more cost-effective than the Dutch system. Medical effectiveness will be assessed at four different time points by means of patient self-reported questionnaires and functional tests. Assessments include the Hip disability and Osteoarthritis Outcome Score, Patient Acceptable Symptom State, Short Form 36, EuroQol 5 Dimensions 3 Level Questionnaire, Timed Up & Go Test and Five Times Sit-to-Stand Test. Additionally, long-term economic aspects in both countries will be assessed from a societal perspective, to get a first impression on whether cutting costs for rehabilitation, as practised in the Netherlands, really disburdens the healthcare system efficiently. The study is approved by the Institutional Review Boards of both University Medical Center Groningen (METc2015/483) and Hannover Medical School (no 2874-2015) and will be conducted according to the principles of the Declaration of Helsinki (64th, 2013). The results of the study will be published in international peer-reviewed scientific journals. Patient data will be presented anonymously in any publication or scientific journal. DRKS00011345; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. Does hydroxyapatite coating have no advantage over porous coating in primary total hip arthroplasty? A meta-analysis.

    PubMed

    Chen, Yun-Lin; Lin, Tiao; Liu, An; Shi, Ming-Min; Hu, Bin; Shi, Zhong-Li; Yan, Shi-Gui

    2015-01-28

    There are some arguments between the use of hydroxyapatite and porous coating. Some studies have shown that there is no difference between these two coatings in total hip arthroplasty (THA), while several other studies have shown that hydroxyapatite has advantages over the porous one. We have collected the studies in Pubmed, MEDLINE, EMBASE, and the Cochrane library from the earliest possible years to present, with the search strategy of "(HA OR hydroxyapatite) AND ((total hip arthroplasty) OR (total hip replacement)) AND (RCT* OR randomiz* OR control* OR compar* OR trial*)". The randomized controlled trials and comparative observation trials that evaluated the clinical and radiographic effects between hydroxyapatite coating and porous coating were included. Our main outcome measurements were Harris hip score (HHS) and survival, while the secondary outcome measurements were osteolysis, radiolucent lines, and polyethylene wear. Twelve RCTs and 9 comparative observation trials were included. Hydroxyapatite coating could improve the HHS (p < 0.01), reduce the incidence of thigh pain (p = 0.01), and reduce the incidence of femoral osteolysis (p = 0.01), but hydroxyapatite coating had no advantages on survival (p = 0.32), polyethylene wear (p = 0.08), and radiolucent lines (p = 0.78). Hydroxyapatite coating has shown to have an advantage over porous coating. The HHS and survival was duration-dependent-if given the sufficient duration of follow-up, hydroxyapatite coating would be better than porous coating for the survival. The properties of hydroxyapatite and the implant design had influence on thigh pain incidence, femoral osteolysis, and polyethylene wear. Thickness of 50 to 80 μm and purity larger than 90% increased the thigh pain incidence. Anatomic design had less polyethylene wear.

  12. Efficacy of thigh volume ratios assessed via stereovision body imaging as a predictor of visceral adipose tissue measured by magnetic resonance imaging

    PubMed Central

    Lee, Jane J; Freeland-Graves, Jeanne H; Pepper, M Reese; Yu, Wurong; Xu, Bugao

    2014-01-01

    Objectives The research examined the efficacy of regional volumes of thigh ratios assessed by stereovision body imaging (SBI) as a predictor of visceral adipose tissue measured by magnetic resonance imaging (MRI). Body measurements obtained via SBI also were utilized to explore disparities of body size and shape in men and women. Method 121 participants were measured for total/regional body volumes and ratios via SBI and abdominal subcutaneous and visceral adipose tissue areas by MRI. Results Thigh to torso and thigh to abdomen-hip volume ratios were the most reliable parameters to predict the accumulation of visceral adipose tissue depots compared to other body measurements. Thigh volume in relation to torso [odds ratios (OR) 0.44] and abdomen-hip (OR 0.41) volumes were negatively associated with increased risks of greater visceral adipose tissue depots, even after controlling for age, gender, and body mass index (BMI). Irrespective of BMI classification, men exhibited greater total body (80.95L vs. 72.41L), torso (39.26L vs. 34.13L), and abdomen-hip (29.01L vs. 25.85L) volumes than women. Women had higher thigh volumes (4.93L vs. 3.99L) and lower-body volume ratios [thigh to total body (0.07 vs. 0.05), thigh to torso (0.15 vs. 0.11), and thigh to abdomen-hip (0.20 vs. 0.15); p<0.05]. Conclusions The unique parameters of the volumes of thigh in relation to torso and abdomen-hip, by SBI were highly effective in predicting visceral adipose tissue deposition. The SBI provided an efficient method for determining body size and shape in men and women via total and regional body volumes and ratios. PMID:25645428

  13. Regional vs. general anesthesia for total knee and hip replacement: An analysis of postoperative pain perception from the international PAIN OUT registry.

    PubMed

    Donauer, Katharina; Bomberg, Hagen; Wagenpfeil, Stefan; Volk, Thomas; Meissner, Winfried; Wolf, Alexander

    2018-05-14

    Total hip and knee replacements are common surgeries, and an optimal pain treatment is essential for early rehabilitation. Since data from randomized controlled trails on the use of regional anesthesia in joint replacements of the lower extremities are conflicting, we analyzed the international PAIN OUT registry for comparison of regional anesthesia vs. general anesthesia regarding pain and morphine consumption on the first postoperative day. International Classification of Diseases-9 (ICD-9) codes were used to identify 2,346 cases for knee and 2,315 for hip arthroplasty between 2010 and 2016 from the PAIN OUT registry. Those were grouped according to anesthesia provided (general, regional, and a combination of both). At the first day after surgery, pain levels and opioid consumption was compared. Adjusted odds ratios (aOR [95% CI]) were calculated with logistic regression and propensity matching was used as a sensitivity analysis. After adjustment for confounders, regional anesthesia was associated with reduced opioid consumption (0.20 [0.13-0.30], p<0.001) and less pain (0.53 [0.36-0.78], p=0.001) than general anesthesia in knee surgery. In hip surgery, regional anesthesia was only associated with reduced opioid consumption (0.17 [0.11-0.26], p<0.001), whereas pain was comparable (1.23 [0.94-1.61], p=0.1). Results from a propensity-matched sensitivity analysis were similar. In total knee arthroplasty, regional anesthesia was associated with less pain and lower opioid consumption. In total hip arthroplasty, regional anesthesia was associated with a lower opioid consumption, however not with reduced pain levels. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  14. Carotenoids and risk of fracture: a meta-analysis of observational studies

    PubMed Central

    Song, Xiaochao; Zhang, Xi; Li, Xinli

    2017-01-01

    To quantify the association between dietary and circulating carotenoids and fracture risk, a meta-analysis was conducted by searching MEDLINE and EMBASE databases for eligible articles published before May 2016. Five prospective and 2 case-control studies with 140,265 participants and 4,324 cases were identified in our meta-analysis. Among which 5 studies assessed the association between dietary carotenoids levels and hip fracture risk, 2 studies focused on the association between circulating carotenoids levels and any fracture risk. A random-effects model was employed to summarize the risk estimations and their 95% confidence intervals (CIs). Hip fracture risk among participants with high dietary total carotenoids intake was 28% lower than that in participants with low dietary total carotenoids (OR: 0.72; 95% CI: 0.51, 1.01). A similar risk of hip fracture was found for β-carotene based on 5 studies, the summarized OR for high vs. low dietary β-carotene was 0.72 (95% CI: 0.54, 0.95). However, a significant between-study heterogeneity was found (total carotene: I2 = 59.4%, P = 0.06; β-carotene: I2 = 74.4%, P = 0.04). Other individual carotenoids did not show significant associations with hip fracture risk. Circulating carotene levels had no significant association with any fracture risk, the pooled OR (95% CI) was 0.83 (0.59, 1.17). Based on the evidence from observational studies, our meta-analysis supported the hypothesis that higher dietary total carotenoids or β-carotene intake might be potentially associated with a low risk of hip fracture, however, future well-designed prospective cohort studies and randomized controlled trials are warranted to specify the associations between carotenoids and fracture. PMID:27911854

  15. Carotenoids and risk of fracture: a meta-analysis of observational studies.

    PubMed

    Xu, Jiuhong; Song, Chunli; Song, Xiaochao; Zhang, Xi; Li, Xinli

    2017-01-10

    To quantify the association between dietary and circulating carotenoids and fracture risk, a meta-analysis was conducted by searching MEDLINE and EMBASE databases for eligible articles published before May 2016. Five prospective and 2 case-control studies with 140,265 participants and 4,324 cases were identified in our meta-analysis. Among which 5 studies assessed the association between dietary carotenoids levels and hip fracture risk, 2 studies focused on the association between circulating carotenoids levels and any fracture risk. A random-effects model was employed to summarize the risk estimations and their 95% confidence intervals (CIs). Hip fracture risk among participants with high dietary total carotenoids intake was 28% lower than that in participants with low dietary total carotenoids (OR: 0.72; 95% CI: 0.51, 1.01). A similar risk of hip fracture was found for β-carotene based on 5 studies, the summarized OR for high vs. low dietary β-carotene was 0.72 (95% CI: 0.54, 0.95). However, a significant between-study heterogeneity was found (total carotene: I2 = 59.4%, P = 0.06; β-carotene: I2 = 74.4%, P = 0.04). Other individual carotenoids did not show significant associations with hip fracture risk. Circulating carotene levels had no significant association with any fracture risk, the pooled OR (95% CI) was 0.83 (0.59, 1.17). Based on the evidence from observational studies, our meta-analysis supported the hypothesis that higher dietary total carotenoids or β-carotene intake might be potentially associated with a low risk of hip fracture, however, future well-designed prospective cohort studies and randomized controlled trials are warranted to specify the associations between carotenoids and fracture.

  16. [Vitamin D levels among Chilean older subjects with low energy hip fracture].

    PubMed

    Schweitzer, Daniel; Amenábar, Pedro Pablo; Botello, Eduardo; López, Mario; Saavedra, Yocelin; Klaber, Ianiv

    2016-02-01

    Vitamin D deficiency is a common condition affecting 40-100% of geriatric population. To determine the prevalence of vitamin D insufficiency and deficiency in geriatric population surgically treated for hip fracture. Analysis of a database of patients aged over 60 years operated for a low energy hip fracture in a three years period. Vitamin D was measured in identified patients, using a blood sample obtained on admission to the hospital. A logistic regression was carried out to evaluate age, gender, morbidity index and season as predictors of vitamin D deficiency. Two hundred and twenty-eight patients aged 84 ± 7 years (82% females), were included in the analysis. One hundred eighty-three patients (80%) presented vitamin D levels below 20 ng/dl (deficiency) and 39 patients (18%) presented with levels between 20 and 30 ng/dl (insufficiency), totaling 98% of patients with hypovitaminosis D. Vitamin D deficiency was especially common among patients with higher American Society of Anesthesiologists (ASA) Physical Status Classification System and during winter-spring period. A negative correlation between age and the proportion of subjects with vitamin D deficiency was found. There was no relation between gender and vitamin D levels. Vitamin D deficiency is especially prevalent in older subjects with hip fracture, reaching 98% in the studied population.

  17. Total hip arthroplasty and cardiovascular complications: a review.

    PubMed

    Taheriazam, Afshin; Saeidinia, Amin; Keihanian, Faeze

    2018-01-01

    Most adverse events following total hip arthroplasty (THA) are uncommon and preventable or treated easily as expected. Adverse effects related to any major surgical procedure, including anesthesia, performing with other medical problems, drugs, and allergic reactions, might also occur. Potential cardiovascular complications are known to occur during or following THA and will be reviewed here. Complications can be categorized as myocardial infarction, cardiac arrest, thromboembolism, and so on. Special considerations in cardiovascular procedures are also reviewed in this paper.

  18. Total Hip Arthroplasty in Patients With Avascular Necrosis After Hematopoietic Stem Cell Transplantation.

    PubMed

    Vijapura, Anita; Levine, Harlan B; Donato, Michele; Hartzband, Mark A; Baker, Melissa; Klein, Gregg R

    2018-03-01

    The immunosuppressive regimens required for hematopoietic stem cell transplantation predispose recipients to complications, including avascular necrosis. Cancer-related comorbidities, immunosuppression, and poor bone quality theoretically increase the risk for perioperative medical complications, infection, and implant-related complications in total joint arthroplasty. This study reviewed 20 primary total hip arthroplasties for avascular necrosis in 14 patients. Outcomes were assessed at routine clinical visits and Harris hip scores were calculated. Follow-up radiographs were evaluated for component malposition, loosening, polyethylene wear, and osteolysis. Average follow-up was 44.5 months for all patients. Postoperative clinical follow-up revealed good to excellent outcomes, with significant improvement in functional outcome scores. There were no periprosthetic infections or revisions for aseptic loosening. There was 1 dislocation on postoperative day 40, which was treated successfully with a closed reduction. Two patients with a prior history of venous thromboembolism developed a pulmonary embolus on postoperative day 13 and 77, respectively. Four patients died several months to years after arthroplasty of complications unrelated to the surgical procedure. Total hip arthroplasty can both be safely performed and greatly improve quality of life in recipients of hematopoietic stem cell transplantation who develop avascular necrosis. However, prolonged venous thromboembolism prophylaxis should be carefully considered in this high-risk patient population. [Orthopedics. 2018; 41(2):e257-e261.]. Copyright 2018, SLACK Incorporated.

  19. Six years of continuous intrathecal infusion of opioid and bupivacaine in the treatment of refractory pain due to intrapelvic extrusion of bone cement after total hip arthroplasty.

    PubMed

    Dahm, P O; Nitescu, P V; Appelgren, L K; Curelaru, I D

    1998-01-01

    There is at present no reliable method for long-term treatment of severe pain following complications of total hip arthroplasty. We explored the long-term use of continuous intrathecal opioid/bupivacaine analgesia in a case not amendable to corrective surgery. A 77-year-old woman, having a total hip arthroplasty, developed refractory nociceptive-neuropathic pain located at the ventral and dorsal aspects of the left hip. Radiographs showed a mandarine-sized intrapelvic mass of bone cement adhering to the roof of the acetabular cup. Further surgery had been declined by the surgeon and by the patient. An 18-gauge Portex intrathecal catheter was inserted, and an intrathecal infusion of 4.75 mg/mL bupivacaine and 0.015 mg/mL buprenorphine was started from a portable Pharmacia-Deltec (St. Paul, Minnesota) pump. The mean daily doses during the treatment period (more than 6 years up to now) were 37 mg for bupivacaine and 0.114 mg for buprenorphine. The intrathecal treatment gave the patient 85-100% pain relief. The patient could transport herself in a wheelchair, was able to perform her own hygiene, receive visits, read, watch television, and also shop and visit restaurants. There has been no need to replace the intrathecal catheter. Intrathecal infusion of opioid/bupivacaine can provide satisfactory long-term analgesia in patients with refractory pain from the hip joint.

  20. Incidence and Risk Factors for Health-Care Associated Infections after Hip Operation.

    PubMed

    Hessels, Amanda J; Agarwal, Mansi; Liu, Jianfang; Larson, Elaine L

    2016-12-01

    Hip operation reduces pain and improves mobility and quality of life for more than 300,000 people annually, most of whom are more than 65 years old. Substantial increases in surgical volume are projected between 2005 and 2030 in primary total (174%) and revision (137%) procedures. This projection demands that the impact of increasing age on the relative risk of health-care associated infections (HAI) after hip surgical procedures be assessed. Our aim was to examine the incidence and risk factors of HAI among patients who underwent hip operations between 2006 and 2012. This secondary analysis included data from patients 18 years old or older and having a hip prosthesis procedure in three New York City hospitals between 2006 and 2012. Procedures were categorized as total or partial hip replacements or revision and re-surfacing procedures. Outcomes of interest were blood stream infections (BSI), urinary tract infections (UTI), or surgical site infections (SSI). Patients in whom an infection developed during the hospital visit in which the hip procedure occurred were counted as cases. Of 2021 patients, approximately 11% (n = 218) had an HAI. There was no difference in infection rates by admission year despite an increase in surgical volume. SSI was associated with younger age, previous hospitalization, and hip revision surgical procedure whereas UTI and BSI were associated with older age, greater co-morbidity, longer pre-operative length of stay and intensive care unit stay, (p < 0.05). HAI after hip operation affected approximately one in 10 patients over a 7-year period in three high-volume hospitals. SSI occurred least frequently, predominantly among patients who underwent revision surgery (without previous SSI), were younger, and had a history of previous hospitalization. Infections such as BSI and UTI, although rare, occurred more frequently and in patients with more co-morbidities, longer pre-operative length of stay, and who required higher level care. Further research to understand these unexpected findings and target interventions is warranted.

Top