Frustrated Total Internal Reflection: A Simple Application and Demonstration.
ERIC Educational Resources Information Center
Zanella, F. P.; Magalhaes, D. V.; Oliveira, M. M.; Bianchi, R. F.; Misoguti, L.; Mendonca, C. R.
2003-01-01
Describes the total internal reflection process that occurs when the internal angle of incidence is equal to or greater than the critical angle. Presents a demonstration of the effect of frustrated total internal reflection (FTIR). (YDS)
Wang, Shinn-Fwu; Chiu, Ming-Hung; Chen, Wei-Wu; Kao, Fu-Hsi; Chang, Rong-Seng
2009-05-01
A small-displacement sensing system based on multiple total internal reflections in heterodyne interferometry is proposed. In this paper, a small displacement can be obtained only by measuring the variation in phase difference between s- and p-polarization states for the total internal reflection effect. In order to improve the sensitivity, we increase the number of total internal reflections by using a parallelogram prism. The theoretical resolution of the method is better than 0.417 nm. The method has some merits, e.g., high resolution, high sensitivity, and real-time measurement. Also, its feasibility is demonstrated.
Prisms with total internal reflection as solar reflectors
Rabl, Arnulf; Rabl, Veronika
1978-01-01
An improved reflective wall for radiant energy collection and concentration devices is provided. The wall is comprised of a plurality of prisms whose frontal faces are adjacent and which reflect the desired radiation by total internal reflection.
An Arduino-Based Experiment Designed to Clarify the Transition to Total Internal Reflection
ERIC Educational Resources Information Center
Atkin, Keith
2018-01-01
The topic of refraction and reflection of light at the boundary of transparent media is a fundamentally important one. The special case of total internal reflection is however commonly misrepresented in elementary textbooks. This paper addresses the problem and describes an experimental procedure for measuring and displaying reflected and…
Nonimaging light concentration using total internal reflection films.
Ouellette, G; Waltham, C E; Drees, R M; Poon, A; Schubank, R; Whitehead, L A
1992-05-01
We present a method of fabricating nonimaging light concentrators from total internal reflection film. A prototype has been made and tested and found to operate in agreement with predictions of ray-tracing codes. The performance of the prototype is comparable with that of concentrators made from specular reflecting materials.
An Arduino-based experiment designed to clarify the transition to total internal reflection
NASA Astrophysics Data System (ADS)
Atkin, Keith
2018-03-01
The topic of refraction and reflection of light at the boundary of transparent media is a fundamentally important one. The special case of total internal reflection is however commonly misrepresented in elementary textbooks. This paper addresses the problem and describes an experimental procedure for measuring and displaying reflected and transmitted light intensities using readily available components and the Arduino microcontroller.
Novel method in solving non-polarizing condition in frustrated total internal reflection layers
NASA Astrophysics Data System (ADS)
Shi, Jin Hui; Wang, Zheng Ping
2008-03-01
When used at oblique angles of incidence, the reflectance and transmittance of thin films exhibit strong polarization effects, particularly for the films inside a glass cube. However, the polarization effects are undesirable in many applications. Novel non-polarizing beam splitter designs are shown, non-polarizing beam splitters with unique optical thin films are achieved through combination of interference and frustrated total internal reflection, the non-polarizing condition expressions based on frustrated total internal reflection is derived, and applied examples of the non-polarizing beam splitters are also presented with the optimization technique and the results of Rp=(50+/-0.4)% and Rs=(50+/-0.4)% in the wavelength range of 500-600nm are obtained.
Total internal reflection laser tools and methods
Zediker, Mark S.; Faircloth, Brian O.; Kolachalam, Sharath K.; Grubb, Daryl L.
2016-02-02
There is provided high power laser tools and laser heads that utilize total internal reflection ("TIR") structures to direct the laser beam along a laser beam path within the TIR structure. The TIR structures may be a TIR prism having its hypotenuse as a TIR surface.
Amplified total internal reflection: theory, analysis, and demonstration of existence via FDTD.
Willis, Keely J; Schneider, John B; Hagness, Susan C
2008-02-04
The explanation of wave behavior upon total internal reflection from a gainy medium has defied consensus for 40 years. We examine this question using both the finite-difference time-domain (FDTD) method and theoretical analyses. FDTD simulations of a localized wave impinging on a gainy half space are based directly on Maxwell's equations and make no underlying assumptions. They reveal that amplification occurs upon total internal reflection from a gainy medium; conversely, amplification does not occur for incidence below the critical angle. Excellent agreement is obtained between the FDTD results and an analytical formulation that employs a new branch cut in the complex "propagation-constant" plane.
Resonant tunneling in frustrated total internal reflection.
Longhi, Stefano
2005-10-15
Anomalous light transmission and resonant tunneling in frustrated total internal reflection (FTIR) are theoretically predicted to occur at periodically curved interfaces. For a low-contrast index and for grazing incidence, it is shown that FTIR resonant tunneling provides an optical realization of field-induced barrier transparency in quantum tunneling.
Frustrated total internal reflection acoustic field sensor
Kallman, Jeffrey S.
2000-01-01
A frustrated total internal reflection acoustic field sensor which allows the acquisition of the acoustic field over an entire plane, all at once. The sensor finds use in acoustic holography and acoustic diffraction tomography. For example, the sensor may be produced by a transparent plate with transparent support members tall enough to support one or more flexible membranes at an appropriate height for frustrated total internal reflection to occur. An acoustic wave causes the membrane to deflect away from its quiescent position and thus changes the amount of light that tunnels through the gap formed by the support members and into the membrane, and so changes the amount of light reflected by the membrane. The sensor(s) is illuminated by a uniform tight field, and the reflection from the sensor yields acoustic wave amplitude and phase information which can be picked up electronically or otherwise.
Even illumination in total internal reflection fluorescence microscopy using laser light.
Fiolka, R; Belyaev, Y; Ewers, H; Stemmer, A
2008-01-01
In modern fluorescence microscopy, lasers are a widely used source of light, both for imaging in total internal reflection and epi-illumination modes. In wide-field imaging, scattering of highly coherent laser light due to imperfections in the light path typically leads to nonuniform illumination of the specimen, compromising image analysis. We report the design and construction of an objective-launch total internal reflection fluorescence microscopy system with excellent evenness of specimen illumination achieved by azimuthal rotation of the incoming illuminating laser beam. The system allows quick and precise changes of the incidence angle of the laser beam and thus can also be used in an epifluorescence mode. 2007 Wiley-Liss, Inc
Electrowetting-actuated optical switch based on total internal reflection.
Liu, Chao; Wang, Di; Yao, Li-Xiao; Li, Lei; Wang, Qiong-Hua
2015-04-01
In this paper we demonstrate a liquid optical switch based on total internal reflection. Two indium tin oxide electrodes are fabricated on the bottom substrate. A conductive liquid (Liquid 1) is placed on one side of the chamber and surrounded by a density-matched silicone oil (Liquid 2). In initial state, when the light beam illuminates the interface of the two liquids, it just meets the conditions of total internal reflection. The light is totally reflected by Liquid 2, and the device shows light-off state. When we apply a voltage to the other side of the indium tin oxide electrode, Liquid 1 stretched towards this side of the substrate and the curvature of the liquid-liquid interface changes. The light beam is refracted by Liquid 1 and the device shows light-on state. So the device can achieve the functions of an optical switch. Because the light beam can be totally reflected by the liquid, the device can attain 100% light intensity attenuation. Our experiments show that the response time from light-on (off) to light-off (on) are 130 and 132 ms, respectively. The proposed optical switch has potential applications in variable optical attenuators, information displays, and light shutters.
Revisit: A Surprising Demonstration of Total Internal Reflection
ERIC Educational Resources Information Center
Lee, Jiwon; Cha, Yu Wha; Jung, Yeon Su; Oh, Eun Ju; Moon, Ye Lin; Kim, Jung Bog
2016-01-01
Melton demonstrated a surprising disappearance using total internal reflection. When he put a Florence flask filled with marbles into a water tank and looked straight down from directly above the flask, he was only able to see marbles above a certain water level. When he added more water into the tank above the top line of the marbles, all of the…
Zhang, Jiwei; Di, Jianglei; Li, Ying; Xi, Teli; Zhao, Jianlin
2015-10-19
We present a method for dynamically measuring the refractive index distribution in a large range based on the combination of digital holographic interferometry and total internal reflection. A series of holograms, carrying the index information of mixed liquids adhered on a total reflection prism surface, are recorded with CCD during the diffusion process. Phase shift differences of the reflected light are reconstructed exploiting the principle of double-exposure holographic interferometry. According to the relationship between the reflection phase shift difference and the liquid index, two dimensional index distributions can be directly figured out, assuming that the index of air near the prism surface is constant. The proposed method can also be applied to measure the index of solid media and monitor the index variation during some chemical reaction processes.
Byrne, Gerard D; Vllasaliu, Driton; Falcone, Franco H; Somekh, Michael G; Stolnik, Snjezana
2015-11-02
In this work we utilize the combination of label-free total internal reflection microscopy and total internal reflectance fluorescence (TIRM/TIRF) microscopy to achieve a simultaneous, live imaging of single, label-free colloidal particle endocytosis by individual cells. The TIRM arm of the microscope enables label free imaging of the colloid and cell membrane features, while the TIRF arm images the dynamics of fluorescent-labeled clathrin (protein involved in endocytosis via clathrin pathway), expressed in transfected 3T3 fibroblasts cells. Using a model polymeric colloid and cells with a fluorescently tagged clathrin endocytosis pathway, we demonstrate that wide field TIRM/TIRF coimaging enables live visualization of the process of colloidal particle interaction with the labeled cell structure, which is valuable for discerning the membrane events and route of colloid internalization by the cell. We further show that 500 nm in diameter model polystyrene colloid associates with clathrin, prior to and during its cellular internalization. This association is not apparent with larger, 1 μm in diameter colloids, indicating an upper particle size limit for clathrin-mediated endocytosis.
Diffractive flat panel solar concentrators of a novel design.
de Jong, Ties M; de Boer, Dick K G; Bastiaansen, Cees W M
2016-07-11
A novel design for a flat panel solar concentrator is presented which is based on a light guide with a grating applied on top that diffracts light into total internal reflection. By combining geometrical and diffractive optics the geometrical concentration ratio is optimized according to the principles of nonimaging optics, while the thickness of the device is minimized due to the use of total internal reflection.
DIRC Dreams: Research Directions for the Next Generation of Internally Reflected Imaging Counters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ratcliff, Blair N.
1999-08-17
Some conceptual design features of the total internally reflecting,imaging Cherenkov counter (DIRC) are described. Limits of the DIRC approach to particle identification, and a few features of alternative DIRC designs, are briefly explored.
Refractive index measurement for biomaterial samples by total internal reflection.
Jin, Y L; Chen, J Y; Xu, L; Wang, P N
2006-10-21
The refractive index of biological tissue is a fundamental parameter in applications of optical diagnosis and laser treatments. In the present work, the refractive indices and thermo-optic coefficients of some basic biomaterials, such as blood plasma, haemoglobin solution and lipid membrane, were studied by the method of total internal reflection at the wavelengths of 532 and 632.8 nm that are the most frequently used laser wavelengths in the biomedical field. The effects of the sample concentration and the temperature on refractive index were measured, and empirical relationships were summarized, accompanied by a theoretical explanation based on molecular polarization theory. The results provide some fundamental data for the refractive indices of these biomaterials under variant conditions, and also demonstrate that the total internal reflection method is a feasible and reliable way to measure the refractive indices of biological samples.
Total internal reflection optical switch using the reverse breakdown of a pn junction in silicon.
Kim, Jong-Hun; Park, Hyo-Hoon
2015-11-01
We demonstrate a new type of silicon total-internal-reflection optical switch with a simple pn junction functioning both as a reflector and a heater. The reflector is placed between asymmetrically y-branched multimode waveguides with an inclination angle corresponding to half of the branch angle. When the reflector is at rest, incident light is reflected in accordance to the refractive index difference due to the plasma dispersion effect of the pre-doped carriers. Switching to the transmission state is attained under a reverse breakdown of the pn junction by the thermo-optic effect which smears the refractive index difference. From this switching scheme, we confirmed the switching operation with a shallow total-internal-reflection region of 1 μm width. At a 6° branch angle, an extinction ratio of 12 dB and an insertion loss of -4.2 dB are achieved along with a thermal heating power of 151.5 mW.
NASA Astrophysics Data System (ADS)
Wang, Hong; Li, Xiufeng; Ge, Peng
2017-02-01
We propose a design method of an optical lens combined with a total internal reflection (TIR) freeform surface for a LED front fog lamp. The TIR freeform surface controls the edge rays of the LED source. It totally reflects the edge rays and makes them emit from the top surface of the lens. And the middle rays of the LED source go through the refractive surface and reach the measured plane. We simulate the model by Monte Carlo method. Simulation results show that the front fog lamp system can satisfy the requirement of ECE R19 Rev7. The light control efficiency can reach up to 76%.
Oreopoulos, John; Yip, Christopher M.
2009-01-01
Determining the local structure, dynamics, and conformational requirements for protein-protein and protein-lipid interactions in membranes is critical to understanding biological processes ranging from signaling to the translocating and membranolytic action of antimicrobial peptides. We report here the application of a combined polarized total internal reflection fluorescence microscopy-in situ atomic force microscopy platform. This platform's ability to image membrane orientational order was demonstrated on DOPC/DSPC/cholesterol model membranes containing the fluorescent membrane probe, DiI-C20 or BODIPY-PC. Spatially resolved order parameters and fluorophore tilt angles extracted from the polarized total internal reflection fluorescence microscopy images were in good agreement with the topographical details resolved by in situ atomic force microscopy, portending use of this technique for high-resolution characterization of membrane domain structures and peptide-membrane interactions. PMID:19254557
A Feasibility Study on Generation of Acoustic Waves Utilizing Evanescent Light
NASA Astrophysics Data System (ADS)
Matsuya, I.; Matozaki, K.; Kosugi, A.; Ihara, I.
2014-06-01
A new approach of generating acoustic waves utilizing evanescent light is presented. The evanescent light is a non-propagating electromagnetic wave that exhibits exponential decay with distance from the surface at which the total internal reflection of light is formed. In this research, the evanescent light during total internal reflection at prism surface is utilized for generating acoustic waves in aluminium and the feasibility for ultrasonic measurements is discussed. Pulsed Nd:YAG laser with 0.36 J/cm2 power density is used and the incident angle during the total internal reflection is arranged to be 69.0° for generating the evanescent light. It has been demonstrated that the amplitude of the acoustic waves by means of evanescent light is about 1/14 as large as the one generated by the conventional pulsed laser. This reveals the possibility of using a laser ultrasonic technique with near-field optics.
Total Internal Reflection Accounts for the Bright Color of the Saharan Silver Ant
Aron, Serge
2016-01-01
The Saharan silver ant Cataglyphis bombycina is one of the terrestrial living organisms best adapted to tolerate high temperatures. It has recently been shown that the hairs covering the ant’s dorsal body part are responsible for its silvery appearance. The hairs have a triangular cross-section with two corrugated surfaces allowing a high optical reflection in the visible and near-infrared (NIR) range of the spectrum while maximizing heat emissivity in the mid-infrared (MIR). Those two effects account for remarkable thermoregulatory properties, enabling the ant to maintain a lower thermal steady state and to cope with the high temperature of its natural habitat. In this paper, we further investigate how geometrical optical and high reflection properties account for the bright silver color of C. bombycina. Using optical ray-tracing models and attenuated total reflection (ATR) experiments, we show that, for a large range of incidence angles, total internal reflection (TIR) conditions are satisfied on the basal face of each hair for light entering and exiting through its upper faces. The reflection properties of the hairs are further enhanced by the presence of the corrugated surface, giving them an almost total specular reflectance for most incidence angles. We also show that hairs provide an almost 10-fold increase in light reflection, and we confirm experimentally that they are responsible for a lower internal body temperature under incident sunlight. Overall, this study improves our understanding of the optical mechanisms responsible for the silver color of C. bombycina and the remarkable thermoregulatory properties of the hair coat covering the ant’s body. PMID:27073923
ERIC Educational Resources Information Center
Foley, Tyler; Pegram, Matthew; Jenkins, Zachary; Hester, Brooke C.; Burris, Jennifer L.
2015-01-01
We have developed an eye-catching demonstration that showcases a variety of physics topics from total internal reflection to electrostatics to non-Newtonian fluid dynamics, including the Kaye effect. The essential components of the demonstration include a vertical stream of liquid soap in which a laser pointer is internally reflected, and which…
NASA Astrophysics Data System (ADS)
Cadatal-Raduban, Marilou; Pham, Minh Hong; Pham, Duong Van; Bui, Duong Thi Thuy; Yamanoi, Kohei; Takeda, Kohei; Empizo, Melvin John F.; Mui, Luong Viet; Shimizu, Toshihiko; Nguyen, Hung Dai; Sarukura, Nobuhiko; Fukuda, Tsuguo
2018-06-01
A two-side-pumping scheme that is based on total internal reflection in a diamond-cut Ce3+:LiCaAlF6 crystal suitable for the development of an ultraviolet laser and femtosecond amplifier system is proposed. Experimental fluorescence images and lasing results that demonstrate total internal reflection of the excitation beam using this diamond-cut crystal are presented. Calculations for the optimized crystal geometry that facilitate high extraction efficiency and homogeneity of the absorbed excitation beam are also discussed. About 50% increase in extraction efficiency compared to previously reported chirped-pulse femtosecond ultraviolet amplifier operating at 50-GW peak power is expected using this total internal reflection-based two-side-pumping configuration and a diamond-cut Ce3+:LiCaAlF6 crystal with a geometry of {φ _1} = 103°, {φ _2} = {φ _4} = 82°, {φ _3} = 93°, a length of 1.23 cm, a height of 2 cm, and an absorption coefficient of 1.5 cm-1. Our results can be used as a guide during the crystal growth process by providing the appropriate crystal geometry and size for a particular absorption coefficient to achieve high extraction efficiency. With the appropriate crystal combined with multiple-beam pumping afforded by the side-pumping scheme, the development of an all-solid-state ultraviolet laser operating at terawatt level would be within reach.
Hull, J R
1989-01-01
Coupling a dielectric compound parabolic concentrator (DCPC) to an absorber across a vacuum gap by means of frustrated total internal reflection (FTIR) can theoretically approach the maximum concentration permitted by physical laws, thus allowing higher radiative fluxes in thermal applications. The calculated optical performance of 2-D DCPCs with FTIR absorbers indicates that the ratio of gap thickness to optical wavelength must be <0.22 before the optical performance of the DCPC is superior to that of the nondielectric CPC.
Chung, Euiheon; Kim, Daekeun; Cui, Yan; Kim, Yang-Hyo; So, Peter T. C.
2007-01-01
The development of high resolution, high speed imaging techniques allows the study of dynamical processes in biological systems. Lateral resolution improvement of up to a factor of 2 has been achieved using structured illumination. In a total internal reflection fluorescence microscope, an evanescence excitation field is formed as light is total internally reflected at an interface between a high and a low index medium. The <100 nm penetration depth of evanescence field ensures a thin excitation region resulting in low background fluorescence. We present even higher resolution wide-field biological imaging by use of standing wave total internal reflection fluorescence (SW-TIRF). Evanescent standing wave (SW) illumination is used to generate a sinusoidal high spatial frequency fringe pattern on specimen for lateral resolution enhancement. To prevent thermal drift of the SW, novel detection and estimation of the SW phase with real-time feedback control is devised for the stabilization and control of the fringe phase. SW-TIRF is a wide-field superresolution technique with resolution better than a fifth of emission wavelength or ∼100 nm lateral resolution. We demonstrate the performance of the SW-TIRF microscopy using one- and two-directional SW illumination with a biological sample of cellular actin cytoskeleton of mouse fibroblast cells as well as single semiconductor nanocrystal molecules. The results confirm the superior resolution of SW-TIRF in addition to the merit of a high signal/background ratio from TIRF microscopy. PMID:17483188
Broad Band Intra-Cavity Total Reflection Chemical Sensor
Pipino, Andrew C. R.
1998-11-10
A broadband, ultrahigh-sensitivity chemical sensor is provided that allows etection through utilization of a small, extremely low-loss, monolithic optical cavity. The cavity is fabricated from highly transparent optical material in the shape of a regular polygon with one or more convex facets to form a stable resonator for ray trajectories sustained by total internal reflection. Optical radiation enters and exits the monolithic cavity by photon tunneling in which two totally reflecting surfaces are brought into close proximity. In the presence of absorbing material, the loss per pass is increased since the evanescent waves that exist exterior to the cavity at points where the circulating pulse is totally reflected, are absorbed. The decay rate of an injected pulse is determined by coupling out an infinitesimal fraction of the pulse to produce an intensity-versus-time decay curve. Since the change in the decay rate resulting from absorption is inversely proportional to the magnitude of absorption, a quantitative sensor of concentration or absorption cross-section with 1 part-per-million/pass or better sensitivity is obtained. The broadband nature of total internal reflection permits a single device to be used over a broad wavelength range. The absorption spectrum of the surrounding medium can thereby be obtained as a measurement of inverse decay time as a function of wavelength.
Nonimaging light concentrator with uniform irradiance
Winston, Roland; Gee, Randy C.
2003-04-01
A nonimaging light concentrator system including a primary collector of light, an optical mixer disposed near the focal zone for collecting light from the primary collector, the optical mixer having a transparent entrance aperture, an internally reflective housing for substantially total internal reflection of light, a transparent exit aperture and an array of photovoltaic cells disposed near the transparent exit aperture.
Wang, Shinn-Fwu
2009-01-01
A small-displacement sensor based on total-internal reflection theory and surface plasmon resonance technology is proposed for use in heterodyne interferometry. A small displacement can be obtained simply by measuring the variation in phase difference between s- and p-polarization states with the small-displacement sensor. The theoretical displacement resolution of the small-displacement sensor can reach 0.45 nm. The sensor has some additional advantages, e.g., a simple optical setup, high resolution, high sensitivity and rapid measurement. Its feasibility is also demonstrated.
Microplate-compatible total internal reflection fluorescence microscopy for receptor pharmacology
NASA Astrophysics Data System (ADS)
Chen, Minghan; Zaytseva, Natalya V.; Wu, Qi; Li, Min; Fang, Ye
2013-05-01
We report the use of total internal reflection fluorescence (TIRF) microscopy for analyzing receptor pharmacology and the development of a microplate-compatible TIRF imaging system. Using stably expressed green fluorescence protein tagged β2-adrenergic receptor as the reporter, we found that the activation of different receptors results in distinct kinetic signatures of the TIRF intensity of cells. These TIRF signatures closely resemble the characteristics of their respective label-free dynamic mass redistribution signals in the same cells. This suggests that TIRF in microplate can be used for profiling and screening drugs.
NASA Astrophysics Data System (ADS)
Nabok, A. V.; Tsargorodskaya, A.; Hassan, A. K.; Starodub, N. F.
2005-06-01
The environmental toxins, such as herbicides simazine and atrazine, and T2 mycotoxin were registered with the optical methods of surface plasmon resonance (SPR) and recently developed total internal reflection ellipsometry (TIRE). The immune assay approach was exploited for in situ registration of the above low molecular weight toxins with specific antibodies immobilised onto the gold surface via (poly)allylamine hydrochloride layer using electrostatic self-assembly (ESA) technique. The comparison of two methods of SPR and TIRE shows a higher sensitivity of the latter.
Wallhead, Ian; Jiménez, Teresa Molina; Ortiz, Jose Vicente García; Toledo, Ignacio Gonzalez; Toledo, Cristóbal Gonzalez
2012-11-05
A novel of Fresnel-type lens for use as a solar collector has been designed which utilizes double total internal reflection (D-TIR) to optimize collection efficiency for high numerical aperture lenses (in the region of 0.3 to 0.6 NA). Results show that, depending on the numerical aperture and the size of the receiver, a collection efficiency theoretical improvement on the order of 20% can be expected with this new design compared with that of a conventional Fresnel lens.
NASA Technical Reports Server (NTRS)
Harper, L. L. (Inventor)
1983-01-01
An optical resonator cavity configuration has a unitary mirror with oppositely directed convex and concave reflective surfaces disposed into one fold and concertedly reversing both ends of a beam propagating from a laser rod disposed between two total internal reflection prisms. The optical components are rigidly positioned with perpendicularly crossed virtual rooflines by a compact optical bed. The rooflines of the internal reflection prisms, are arranged perpendicularly to the axis of the laser beam and to the optical axes of the optical resonator components.
Internal high-reflectivity omni-directional reflectors
NASA Astrophysics Data System (ADS)
Xi, J.-Q.; Ojha, Manas; Plawsky, J. L.; Gill, W. N.; Kim, Jong Kyu; Schubert, E. F.
2005-07-01
An internal high-reflectivity omni-directional reflector (ODR) for the visible spectrum is realized by the combination of total internal reflection using a low-refractive-index (low-n) material and reflection from a one-dimensional photonic crystal (1D PC). The low-n layer limits the range of angles in the 1D PC to values below the Brewster angle, thereby enabling high reflectivity and omni-directionality. This ODR is demonstrated using GaP as ambient, nanoporous SiO2 with a very low refractive index (n=1.10), and a four-pair TiO2/SiO2 multilayer stack. The results indicate a two orders of magnitude lower angle-integrated transverse-electric-transverse-magnetic polarization averaged mirror loss of the ODR compared with conventional distributed Bragg reflectors and metal reflectors. This indicates the high potential of the internal ODRs for optoelectronic semiconductor devices, e.g., light-emitting diodes.
Theoretical analysis of non-polarizing beam splitters with appropriate amplitude and phase
NASA Astrophysics Data System (ADS)
Shi, Jin Hui; Wang, Zheng Ping; Guan, Chun Ying
2009-04-01
When used at oblique angles of incidence, the reflectance and transmittance of thin films exhibit strong polarization effects, particularly for the films inside a glass cube. However, the polarization effects are undesirable in many applications. Novel non-polarizing beam splitter designs are shown. Non-polarizing beam splitters with unique optical thin films are achieved through the combination of interference and frustrated total internal reflection. The non-polarizing condition expressions based on frustrated total internal reflection are derived, and examples of the non-polarizing beam splitters are also presented with the optimization technique and the results of Rp=(50±0.5)%, Rs=(50±0.5)%, and Δr=(0±0.3) in the wavelength range of 400-700 nm are obtained.
Kuang, Cuifang; Ali, M Yakut; Hao, Xiang; Wang, Tingting; Liu, Xu
2010-10-01
In order to achieve a higher axial resolution for displacement measurement, a novel method is proposed based on total internal reflection filter and confocal microscope principle. A theoretical analysis of the basic measurement principles is presented. The analysis reveals that the proposed confocal detection scheme is effective in enhancing the resolution of nonlinearity of the reflectance curve greatly. In addition, a simple prototype system has been developed based on the theoretical analysis and a series of experiments have been performed under laboratory conditions to verify the system feasibility, accuracy, and stability. The experimental results demonstrate that the axial resolution in displacement measurements is better than 1 nm in a range of 200 nm which is threefold better than that can be achieved using the plane reflector.
Design and analysis of non-polarizing beam splitter in a glass cube
NASA Astrophysics Data System (ADS)
Shi, Jinhui; Wang, Zhengping; Huang, Zongjun; Li, Qingbo
2008-11-01
The reflectance and transmittance of thin films at oblique incident angles exhibit strong polarization effects, particularly for the films inside a glass cube. However, the polarization effects are undesirable in many applications. To solve this problem, non-polarizing beam splitters with unique optical thin films have been achieved employing a method of combination of interference and frustrated total internal reflection, the non-polarizing condition expressions based on frustrated total internal reflection has been derived, and the design examples of non-polarizing beam splitters with an optimization technique have been also presented. The results of Rp=(50+/-0.5)%, Rs=(50+/-0.5)% andΔr=(0+/-0.3) degree in the wavelength range of 400-700nm have been obtained. The thickness sensitivity of NPBSs is also analyzed.
Patterson, Brian M; Havrilla, George J
2006-11-01
The number of techniques and instruments available for Fourier transform infrared (FT-IR) microspectroscopic imaging has grown significantly over the past few years. Attenuated total internal reflectance (ATR) FT-IR microspectroscopy reduces sample preparation time and has simplified the analysis of many difficult samples. FT-IR imaging has become a powerful analytical tool using either a focal plane array or a linear array detector, especially when coupled with a chemometric analysis package. The field of view of the ATR-IR microspectroscopic imaging area can be greatly increased from 300 x 300 microm to 2500 x 2500 microm using a larger internal reflection element of 12.5 mm radius instead of the typical 1.5 mm radius. This gives an area increase of 70x before aberrant effects become too great. Parameters evaluated include the change in penetration depth as a function of beam displacement, measurements of the active area, magnification factor, and change in spatial resolution over the imaging area. Drawbacks such as large file size will also be discussed. This technique has been successfully applied to the FT-IR imaging of polydimethylsiloxane foam cross-sections, latent human fingerprints, and a model inorganic mixture, which demonstrates the usefulness of the method for pharmaceuticals.
Nonpolarizing beam splitter designed by frustrated total internal reflection inside a glass cube.
Xu, Xueke; Shao, Jianda; Fan, Zhengxiu
2006-06-20
A method for the design of an all-dielectric nonpolarizing prism beam splitter utilizing the principle of frustrated total internal reflection is reported. The nonpolarizing condition for a prism beam splitter is discussed, and some single layer design examples are elaborated. The concept can be applied to a wide range of wavelengths and arbitrary transmittance values, and with the help of a computer design program examples of 400-700 nm, T(p)=T(s)=0.5+/-0.01, with incident angles of 45 degrees and 62 degrees are given. In addition, the sensitivity and application of the design are also discussed.
NASA Technical Reports Server (NTRS)
Blumberg, Seth; Gajraj, Arivalagan; Pennington, Matthew W.; Meiners, Jens-Christian
2005-01-01
Tethered particle microscopy is a powerful tool to study the dynamics of DNA molecules and DNA-protein complexes in single-molecule experiments. We demonstrate that stroboscopic total internal reflection microscopy can be used to characterize the three-dimensional spatiotemporal motion of DNA-tethered particles. By calculating characteristic measures such as symmetry and time constants of the motion, well-formed tethers can be distinguished from defective ones for which the motion is dominated by aberrant surface effects. This improves the reliability of measurements on tether dynamics. For instance, in observations of protein-mediated DNA looping, loop formation is distinguished from adsorption and other nonspecific events.
EFFECT OF CHERENKOV LIGHT POLARIZATION ON TOTAL REFLECTION COUNTER
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dowell, J.D.; Duteil, P.; Leontic, B.
1963-01-01
A rugged total internal reflection counter with a 3- to 5cm thick compact radiator was used at the CERN proton synchrotron for beam analysis. The threshold behavior of this counter was compared when filled with glycerol and with turpentine. Turpentine is optically active and rotates the plane of polarization about 7 un. Concent 85% /cm. Figures illustrate the effect of this polarization rotation. (A.G.W.)
"Colgate-Plus"--An Imperfect Light Pipe.
ERIC Educational Resources Information Center
Ouseph, P. J.
1993-01-01
Describes the effects when a clear toothbrush is used as total internally reflecting light pipe when attached to a laser. Several explanations are given describing the nonuniformity of the transmitted light resulting from surface and internal irregularities found in the toothbrush. (MVL)
Increased efficiency with surface texturing in ITO/InP solar cells
NASA Technical Reports Server (NTRS)
Jenkins, Phillip; Landis, Geoffrey A.; Fatemi, Navid; Li, Xiaonan; Scheiman, David; Bailey, Sheila
1992-01-01
Optimization of an InP solar cell with a V-grooved surface is discussed. Total internal reflection in the coverglass reduces surface reflection and can recover light reflected from the front metallization. Results from the first ITO/InP solar cells on low-angle V-grooved substrates are presented, showing a 5.8 percent increase in current.
Micro ring cavity resonator incorporating total internal reflection mirrors
NASA Astrophysics Data System (ADS)
Kim, Doo Gun; Choi, Woon Kyung; Choi, Young Wan; Yi, Jong Chang; Chung, Youngchul; Dagli, Nadir
2007-02-01
We investigate the properties of a multimode-interference (MMI) coupled micro ring cavity resonator with total-internal-reflection (TIR) mirrors and a semiconductor optical amplifier (SOA). The TIR mirrors were fabricated by the self-aligned process with a loss of 0.7 dB per mirror. The length and width of an MMI are 142 μm and 10 μm, respectively. The resulting free spectral range (FSR) of the resonator was approximately 1.698 nm near 1571 nm and the extinction ratio was about 17 dB. These devices might be useful as optical switching and add-drop filters in a photonic integrated circuit or as small and fast resonator devices.
Total-Internal-Reflection Platforms for Chemical and Biological Sensing Applications
NASA Astrophysics Data System (ADS)
Sapsford, Kim E.
Sensing platforms based on the principle of total internal reflection (TIR) represent a fairly mature yet still expanding and exciting field of research. Sensor development has mainly been driven by the need for rapid, stand-alone, automated devices for application in the fields of clinical diagnosis and screening, food and water safety, environmental monitoring, and chemical and biological warfare agent detection. The technologies highlighted in this chapter are continually evolving, taking advantage of emerging advances in microfabrication, lab-on-a-chip, excitation, and detection techniques. This chapter describes many of the underlying principles of TIR-based sensing platforms and additionally focusses on planar TIR fluorescence (TIRF)-based chemical and biological sensors.
Chapter 7: Total internal reflection fluorescence microscopy.
Axelrod, Daniel
2008-01-01
Total internal reflection fluorescence microscopy (TIRFM), also known as evanescent wave microscopy, is used in a wide range of applications, particularly to view single molecules attached to planar surfaces and to study the position and dynamics of molecules and organelles in living culture cells near the contact regions with the glass coverslip. TIRFM selectively illuminates fluorophores only in a very thin (less than 100 nm deep) layer near the substrate, thereby avoiding excitation of fluorophores outside this subresolution optical section. This chapter reviews the history, current applications in cell biology and biochemistry, basic optical theory, combinations with numerous other optical and spectroscopic approaches, and a range of setup methods, both commercial and custom.
NASA Astrophysics Data System (ADS)
Sung, Young Hoon; Jung, Pil-Hoon; Han, Kyung-Hoon; Kim, Yang Doo; Kim, Jang-Joo; Lee, Heon
2017-10-01
In order to increase the out-coupling efficiency of organic light emitting diodes, conical Si oxide nanostructures were formed on a glass substrate using nanoimprint lithography with hydrogen silsesquioxane. Then, the substrate was planarized with TiO2 nanoparticles. Since TiO2 nanoparticles have a higher refractive index than Si oxide, the surface of substrate is physically flat, but optically undulated in a manner that enables optical scattering and suppression of total internal reflection. Subsequently, OLEDs formed on a substrate with nanostructured Si oxide and a TiO2 planarization layer exhibit a 25% increase in out-coupling efficiency by suppressing total internal reflection.
Xie, Peng; Lin, Huichuan; Liu, Yong; Li, Baojun
2014-10-20
We present a waveguide coupling approach for planar waveguide solar concentrator. In this approach, total internal reflection (TIR)-based symmetric air prisms are used as couplers to increase the coupler reflectivity and to maximize the optical efficiency. The proposed concentrator consists of a line focusing cylindrical lens array over a planar waveguide. The TIR-based couplers are located at the focal line of each lens to couple the focused sunlight into the waveguide. The optical system was modeled and simulated with a commercial ray tracing software (Zemax). Results show that the system used with optimized TIR-based couplers can achieve 70% optical efficiency at 50 × geometrical concentration ratio, resulting in a flux concentration ratio of 35 without additional secondary concentrator. An acceptance angle of ± 7.5° is achieved in the x-z plane due to the use of cylindrical lens array as the primary concentrator.
NASA Astrophysics Data System (ADS)
Fujinami, Taku; Kigami, Hiroshi; Unno, Noriyuki; Taniguchi, Jun; Satake, Shin-ichi
2018-06-01
Total internal reflection fluorescence microscopy (TIRFM) is a promising method for measuring fluid flow close to a wall with nanoscale resolution in a process that is termed "multilayer nanoparticle image velocimetry" (MnPIV). TIRFM uses evanescent light that is generated on a substrate (typically a glass slide) by total internal reflection of light. Many researchers have previously studied x- y- z (3D) flows of water close to flat glass slides using MnPIV. On the other hand, a fluid flow close to a structured surface is also important. To measure flows of water near micro-patterns, we previously developed an MnPIV technique that uses a refractive-index-matching method. In previous study, the micropattern is made of a thermoplastic material with a refractive index that closely matches that of water. In this study, ultraviolet nanoimprint lithography was used for fabricating the appropriate micro-patterns because this technique can fabricate a pattern with a high resolution. As a result, we succeeded in performing MnPIV in water with a circular hole array pattern made by ultraviolet nanoimprint using a refractive-index-matching method. We believe that this technique will be helpful in elucidating fluid flows around microstructures.
NASA Astrophysics Data System (ADS)
Fujinami, Taku; Kigami, Hiroshi; Unno, Noriyuki; Taniguchi, Jun; Satake, Shin-ichi
2018-03-01
Total internal reflection fluorescence microscopy (TIRFM) is a promising method for measuring fluid flow close to a wall with nanoscale resolution in a process that is termed "multilayer nanoparticle image velocimetry" (MnPIV). TIRFM uses evanescent light that is generated on a substrate (typically a glass slide) by total internal reflection of light. Many researchers have previously studied x-y-z (3D) flows of water close to flat glass slides using MnPIV. On the other hand, a fluid flow close to a structured surface is also important. To measure flows of water near micro-patterns, we previously developed an MnPIV technique that uses a refractive-index-matching method. In previous study, the micropattern is made of a thermoplastic material with a refractive index that closely matches that of water. In this study, ultraviolet nanoimprint lithography was used for fabricating the appropriate micro-patterns because this technique can fabricate a pattern with a high resolution. As a result, we succeeded in performing MnPIV in water with a circular hole array pattern made by ultraviolet nanoimprint using a refractive-index-matching method. We believe that this technique will be helpful in elucidating fluid flows around microstructures.
Design of an fMRI-compatible optical touch stripe based on frustrated total internal reflection.
Jarrahi, Behnaz; Wanek, Johann
2014-01-01
Previously we developed a low-cost, multi-configurable handheld response system, using a reflective-type intensity modulated fiber-optic sensor (FOS) to accurately gather participants' behavioral responses during functional magnetic resonance imaging (fMRI). Inspired by the popularity and omnipresence of the fingertip-based touch sensing user interface devices, in this paper we present the design of a prototype fMRI-compatible optical touch stripe (OTS) as an alternative configuration. The prototype device takes advantage of a proven frustrated total internal reflection (FTIR) technique. By using a custom-built wedge-shaped optically transparent acrylic prism as an optical waveguide, and a plano-concave lens to provide the required light beam profile, the position of a fingertip touching the surface of the wedge prism can be determined from the deflected light beams that become trapped within the prism by total internal reflection. To achieve maximum sensitivity, the optical design of the wedge prism and lens were optimized through a series of light beam simulations using WinLens 3D Basic software suite. Furthermore, OTS performance and MRI-compatibility were assessed on a 3.0 Tesla MRI scanner running echo planar imaging (EPI) sequences. The results show that the OTS can detect a touch signal at high spatial resolution (about 0.5 cm), and is well suited for use within the MRI environment with average time-variant signal-to-noise ratio (tSNR) loss < 3%.
NASA Astrophysics Data System (ADS)
Chen, Youhua; Cao, Ruizhi; Liu, Wenjie; Zhu, Dazhao; Zhang, Zhiming; Kuang, Cuifang; Liu, Xu
2018-04-01
We present an alternative approach to realize structured illumination microscopy (SIM), which is capable for live cell imaging. The prototype utilizes two sets of scanning galvo mirrors, a polarization converter and a piezo-platform to generate a fast shifted, s-polarization interfered and periodic variable illumination patterns. By changing the angle of the scanning galvanometer, we can change the position of the spots at the pupil plane of the objective lens arbitrarily, making it easy to switch between widefield and total internal reflection fluorescent-SIM mode and adapting the penetration depth in the sample. Also, a twofold resolution improvement is achieved in our experiments. The prototype offers more flexibility of pattern period and illumination orientation changing than previous systems.
Johnson, Heath E; Haugh, Jason M
2013-12-02
This unit focuses on the use of total internal reflection fluorescence (TIRF) microscopy and image analysis methods to study the dynamics of signal transduction mediated by class I phosphoinositide 3-kinases (PI3Ks) in mammalian cells. The first four protocols cover live-cell imaging experiments, image acquisition parameters, and basic image processing and segmentation. These methods are generally applicable to live-cell TIRF experiments. The remaining protocols outline more advanced image analysis methods, which were developed in our laboratory for the purpose of characterizing the spatiotemporal dynamics of PI3K signaling. These methods may be extended to analyze other cellular processes monitored using fluorescent biosensors. Copyright © 2013 John Wiley & Sons, Inc.
Internal Reflection Spectra of Surface Compounds and Adsorbed Molecules
NASA Astrophysics Data System (ADS)
Zolotarev, V. M.; Lygin, V. I.; Tarasevich, B. N.
1981-01-01
The application of attenuated total reflection (ATR) spectroscopy in surface studies of inorganic adsorbents and catalysts, polymers, and optically transparent electrodes is discussed. The basic principles of ATR spectroscopy as applied to surface phenomena are considered, with special reference to thin films, industrial adsorbents and catalysts, and polymer degradation processes. 276 references.
Two-pass-internal second-harmonic generation using a prism coupler.
NASA Technical Reports Server (NTRS)
Gonzalez, D. G.; Nieh, S. T. K.; Steier, W. H.
1973-01-01
A dispersive quartz prism is used to couple the total second harmonic generated in both directions by an internal cavity frequency doubler. The study shows that the dispersion of air and mirror reflection phase shifts can be compensated for by a slight nonphase match condition in the doubler.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ratcliff, Blair N
Some conceptual design features of the total internally reflecting,imaging Cherenkov counter (DIRC) are described. Limits of the DIRC approach to particle identification, and a few features of alternative DIRC designs, are briefly explored.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ratcliff, Blair N
Some general conceptual design features of total internally reflecting, imaging Cherenkov counters (DIRCs) are described. Limits of the DIRC approach to particle identification and a few features of alternative DIRC designs are briefly explored.
NASA Technical Reports Server (NTRS)
Hayes, J. D.
1972-01-01
The feasibility of monitoring volatile contaminants in a large space simulation chamber using techniques of internal reflection spectroscopy was demonstrated analytically and experimentally. The infrared spectral region was selected as the operational spectral range in order to provide unique identification of the contaminants along with sufficient sensitivity to detect trace contaminant concentrations. It was determined theoretically that a monolayer of the contaminants could be detected and identified using optimized experimental procedures. This ability was verified experimentally. Procedures were developed to correct the attenuated total reflectance spectra for thick sample distortion. However, by using two different element designs the need for such correction can be avoided.
Topography of Cells Revealed by Variable-Angle Total Internal Reflection Fluorescence Microscopy.
Cardoso Dos Santos, Marcelina; Déturche, Régis; Vézy, Cyrille; Jaffiol, Rodolphe
2016-09-20
We propose an improved version of variable-angle total internal reflection fluorescence microscopy (vaTIRFM) adapted to modern TIRF setup. This technique involves the recording of a stack of TIRF images, by gradually increasing the incident angle of the light beam on the sample. A comprehensive theory was developed to extract the membrane/substrate separation distance from fluorescently labeled cell membranes. A straightforward image processing was then established to compute the topography of cells with a nanometric axial resolution, typically 10-20 nm. To highlight the new opportunities offered by vaTIRFM to quantify adhesion process of motile cells, adhesion of MDA-MB-231 cancer cells on glass substrate coated with fibronectin was examined. Copyright © 2016 Biophysical Society. Published by Elsevier Inc. All rights reserved.
Registration of T-2 mycotoxin with total internal reflection ellipsometry and QCM impedance methods.
Nabok, A V; Tsargorodskaya, A; Holloway, A; Starodub, N F; Gojster, O
2007-01-15
A sensitive optical method of total internal reflection ellipsometry (TIRE) in conjunction with immune assay approach was exploited for the registration of T-2 mycotoxin in a wide range of concentrations from 100 microg/ml down to 0.15 ng/ml. Association constants of 1.4x10(6) and 1.9x10(7)mol(-1)s for poly- and monoclonal T-2 antibodies, respectively, were evaluated from TIRE kinetic measurements. According to TIRE data fitting, binding of T-2 molecules to antibodies (at saturation) has resulted in the increase in adsorbed layer thickness of 4-5 nm. The QCM impedance measurements data showed anomalously large mass increase and film softening, most likely, due to the binding of large T-2 aggregates to antibodies.
Monlithic nonplanar ring oscillator and method
NASA Technical Reports Server (NTRS)
Nilsson, Alan C. (Inventor); Byer, Robert L. (Inventor)
1991-01-01
A monolithic nonplanar ring oscillator having an optically isotropic solid-state laser body for propagating laser radiation about a nonplanar ring path internal to the laser body is disclosed. The monolithic laser body is configured to produce a 2N reflection nonplanar ring light path, where N is an integer greater than or equal to 2, comprising 2N-1 total internal reflections and one reflection at a coupler in a single round trip. Undirectional traveling wave oscillation of the laser is induced by the geometry of the nonplanar ring path together with the effect of an applied magnetic field and partial polarizer characteristics of the oblique reflection from the coupler. The 6-reflection nonplanar ring oscillator makes possible otpimal unidirectional oscillation (low loss for the oscillating direction of propagation and, simultaneously high loss for the nonoscillating direction of propagation) in monolithic NPROs using materials with index of refraction smaller than the square root of 3, for example, laser glass.
Le, Nam Cao Hoai; Yokokawa, Ryuji; Dao, Dzung Viet; Nguyen, Thien Duy; Wells, John C; Sugiyama, Susumu
2009-01-21
A poly(dimethylsiloxane) (PDMS) chip for Total Internal Reflection (TIR)-based imaging and detection has been developed using Si bulk micromachining and PDMS casting. In this paper, we report the applications of the chip on both inverted and upright fluorescent microscopes and confirm that two types of sample delivery platforms, PDMS microchannel and glass microchannel, can be easily integrated depending on the magnification of an objective lens needed to visualize a sample. Although any device configuration can be achievable, here we performed two experiments to demonstrate the versatility of the microfluidic TIR-based devices. The first experiment was velocity measurement of Nile red microbeads with nominal diameter of 500 nm in a pressure-driven flow. The time-sequenced fluorescent images of microbeads, illuminated by an evanescent field, were cross-correlated by a Particle Image Velocimetry (PIV) program to obtain near-wall velocity field of the microbeads at various flow rates from 500 nl/min to 3000 nl/min. We then evaluated the capabilities of the device for Single Molecule Detection (SMD) of fluorescently labeled DNA molecules from 30 bp to 48.5 kbp and confirm that DNA molecules as short as 1105 bp were detectable. Our versatile, integrated device could provide low-cost and fast accessibility to Total Internal Reflection Fluorescent Microscopy (TIRFM) on both conventional upright and inverted microscopes. It could also be a useful component in a Micro-Total Analysis System (micro-TAS) to analyze nanoparticles or biomolecules near-wall transport or motion.
Bohannon, Kevin P; Holz, Ronald W; Axelrod, Daniel
2017-10-01
The refractive index in the interior of single cells affects the evanescent field depth in quantitative studies using total internal reflection (TIR) fluorescence, but often that index is not well known. We here present method to measure and spatially map the absolute index of refraction in a microscopic sample, by imaging a collimated light beam reflected from the substrate/buffer/cell interference at variable angles of incidence. Above the TIR critical angle (which is a strong function of refractive index), the reflection is 100%, but in the immediate sub-critical angle zone, the reflection intensity is a very strong ascending function of incidence angle. By analyzing the angular position of that edge at each location in the field of view, the local refractive index can be estimated. In addition, by analyzing the steepness of the edge, the distance-to-substrate can be determined. We apply the technique to liquid calibration samples, silica beads, cultured Chinese hamster ovary cells, and primary culture chromaffin cells. The optical technique suffers from decremented lateral resolution, scattering, and interference artifacts. However, it still provides reasonable results for both refractive index (~1.38) and for distance-to-substrate (~150 nm) for the cells, as well as a lateral resolution to about 1 µm.
NASA Astrophysics Data System (ADS)
Lizana, A.; Foldyna, M.; Stchakovsky, M.; Georges, B.; Nicolas, D.; Garcia-Caurel, E.
2013-03-01
High sensitivity of spectroscopic ellipsometry and reflectometry for the characterization of thin films can strongly decrease when layers, typically metals, absorb a significant fraction of the light. In this paper, we propose a solution to overcome this drawback using total internal reflection ellipsometry (TIRE) and exciting a surface longitudinal wave: a plasmon-polariton. As in the attenuated total reflectance technique, TIRE exploits a minimum in the intensity of reflected transversal magnetic (TM) polarized light and enhances the sensitivity of standard methods to thicknesses of absorbing films. Samples under study were stacks of three films, ZnO : Al/Ag/ZnO : Al, deposited on glass substrates. The thickness of the silver layer varied from sample to sample. We performed measurements with a UV-visible phase-modulated ellipsometer, an IR Mueller ellipsometer and a UV-NIR reflectometer. We used the variance-covariance formalism to evaluate the sensitivity of the ellipsometric data to different parameters of the optical model. Results have shown that using TIRE doubled the sensitivity to the silver layer thickness when compared with the standard ellipsometry. Moreover, the thickness of the ZnO : Al layer below the silver layer can be reliably quantified, unlike for the fit of the standard ellipsometry data, which is limited by the absorption of the silver layer.
A high-gain, compact, nonimaging concentrator: RXI.
Miñano, J C; Gonźlez, J C; Benítez, P
1995-12-01
The design procedure of a new nonimaging concentrator (called an RXI) is explained. Rays that impinge on the concentrator aperture, within the acceptance angle, are directed to the receiver by means of one refraction, one reflection, and one total internal reflection. The concentrator can be made as a single dielectric piece (in which the receiver is immersed) whose aspect ratio (thickness/aperture diameter) is close to 1/3. Ray-tracing analysis of a rotational symmetric RXI shows total transmissions of greater than 94.5% (no absorption or reflection losses are considered) when the acceptance angle of the incoming rays is small (<3°) and when the receiver area is the smallest possible (maximal concentration.).
New light-shielding technique for shortening the baffle length of a star sensor
NASA Astrophysics Data System (ADS)
Kawano, Hiroyuki; Sato, Yukio; Mitani, Kenji; Kanai, Hiroshi; Hama, Kazumori
2002-10-01
We have developed a star sensor with a short baffle of 140 mm. Our baffle provides a Sun rejection angle of 35 degrees with stray light attenuation less than the intensity level of a visual magnitude of Mv = +5 for a wide field of view lens of 13x13 degrees. The application of a new light shielding technique taking advantage of total internal reflection phenomena enables us to reduce the baffle length to about three fourths that of the conventional two-stage baffle. We have introduced two ideas to make the baffle length shorter. The one is the application of a nearly half sphere convex lens as the first focusing lens. The bottom surface reflects the scattering rays with high incident angles of over 50 degrees by using the total internal reflection phenomena. The other is the painting of the surface of the baffle with not frosted but gloss black paint. The gloss black paint enables most of the specular reflection rays to go back to outer space without scattering. We confirm the baffle performance mentioned above by scattering ray tracing simulation and a light attenuation experiment in a darkroom on the ground.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohara-Imaizumi, Mica; Aoyagi, Kyota; Akimoto, Yoshihiro
To analyze the exocytosis of glucagon-like peptide-1 (GLP-1) granules, we imaged the motion of GLP-1 granules labeled with enhanced yellow fluorescent protein (Venus) fused to human growth hormone (hGH-Venus) in an enteroendocrine cell line, STC-1 cells, by total internal reflection fluorescent (TIRF) microscopy. We found glucose stimulation caused biphasic GLP-1 granule exocytosis: during the first phase, fusion events occurred from two types of granules (previously docked granules and newcomers), and thereafter continuous fusion was observed mostly from newcomers during the second phase. Closely similar to the insulin granule fusion from pancreatic {beta} cells, the regulated biphasic exocytosis from two typesmore » of granules may be a common mechanism in glucose-evoked hormone release from endocrine cells.« less
Beausang, John F.; Sun, Yujie; Quinlan, Margot E.; Forkey, Joseph N.; Goldman, Yale E.
2013-01-01
In this article, we describe methods to detect the spatial orientation and rotational dynamics of single molecules using polarized total internal reflection fluorescence microscopy (polTIRFM). polTIRFM determines the three-dimensional angular orientation and the extent of wobble of a fluorescent probe bound to the macromolecule of interest. We discuss single-molecule versus ensemble measurements, as well as single-molecule techniques for orientation and rotation, and fluorescent probes for orientation studies. Using calmodulin (CaM) as an example of a target protein, we describe a method for labeling CaM with bifunctional rhodamine (BR). We also describe the physical principles and experimental setup of polTIRFM. We conclude with a brief introduction to assays using polTIRFM to assess the interaction of actin and myosin. PMID:22550303
Fang, Ning; Sun, Wei
2015-04-21
A method, apparatus, and system for improved VA-TIRFM microscopy. The method comprises automatically controlled calibration of one or more laser sources by precise control of presentation of each laser relative a sample for small incremental changes of incident angle over a range of critical TIR angles. The calibration then allows precise scanning of the sample for any of those calibrated angles for higher and more accurate resolution, and better reconstruction of the scans for super resolution reconstruction of the sample. Optionally the system can be controlled for incident angles of the excitation laser at sub-critical angles for pseudo TIRFM. Optionally both above-critical angle and sub critical angle measurements can be accomplished with the same system.
von Olshausen, Philipp; Rohrbach, Alexander
2013-10-15
Coherent imaging is barely applicable in life-science microscopy due to multiple interference artifacts. Here, we show how these interferences can be used to improve image resolution and contrast. We present a dark-field microscopy technique with evanescent illumination via total internal reflection that delivers high-contrast images of coherently scattering samples. By incoherent averaging of multiple coherent images illuminated from different directions we can resolve image structures that remain unresolved by conventional (incoherent) fluorescence microscopy. We provide images of 190 nm beads revealing resolution beyond the diffraction limit and slightly increased object distances. An analytical model is introduced that accounts for the observed effects and which is confirmed by numerical simulations. Our approach may be a route to fast, label-free, super-resolution imaging in live-cell microscopy.
NASA Astrophysics Data System (ADS)
Zude, Manuela; Spinelli, Lorenzo; Dosche, Carsten; Torricelli, Alessandro
2009-08-01
In sweet cherry (Prunus avium), the red pigmentation is correlated with the fruit maturity stage and can be measured by non-invasive spectroscopy. In the present study, the influence of varying fruit scattering coefficients on the fruit remittance spectrum (cw) were corrected with the effective pathlength and refractive index in the fruit tissue obtained with distribution of time-of-flight (DTOF) readings and total internal reflection fluorescence (TIRF) analysis, respectively. The approach was validated on fruits providing variation in the scattering coefficient outside the calibration sample set. In the validation, the measuring uncertainty when non-invasively analyzing fruits with cw method in comparison with combined application of cw, DTOF, and TIRF measurements showed an increase in r2 up to 22.7 % with, however, high errors in all approaches.
Ohara-Imaizumi, Mica; Ohtsuka, Toshihisa; Matsushima, Satsuki; Akimoto, Yoshihiro; Nishiwaki, Chiyono; Nakamichi, Yoko; Kikuta, Toshiteru; Nagai, Shintaro; Kawakami, Hayato; Watanabe, Takashi; Nagamatsu, Shinya
2005-01-01
The cytomatrix at the active zone (CAZ) has been implicated in defining the site of Ca2+-dependent exocytosis of neurotransmitters. Here, we demonstrate the expression and function of ELKS, a protein structurally related to the CAZ protein CAST, in insulin exocytosis. The results of confocal and immunoelectron microscopic analysis showed that ELKS is present in pancreatic β cells and is localized close to insulin granules docked on the plasma membrane-facing blood vessels. Total internal reflection fluorescence microscopy imaging in insulin-producing clonal cells revealed that the ELKS clusters are less dense and unevenly distributed than syntaxin 1 clusters, which are enriched in the plasma membrane. Most of the ELKS clusters were on the docking sites of insulin granules that were colocalized with syntaxin 1 clusters. Total internal reflection fluorescence images of single-granule motion showed that the fusion events of insulin granules mostly occurred on the ELKS cluster, where repeated fusion was sometimes observed. When the Bassoon-binding region of ELKS was introduced into the cells, the docking and fusion of insulin granules were markedly reduced. Moreover, attenuation of ELKS expression by small interfering RNA reduced the glucose-evoked insulin release. These data suggest that the CAZ-related protein ELKS functions in insulin exocytosis from pancreatic β cells. PMID:15888548
NASA Astrophysics Data System (ADS)
Foley, Tyler; Pegram, Matthew; Jenkins, Zachary; Hester, Brooke C.; Burris, Jennifer L.
2015-01-01
We have developed an eye-catching demonstration that showcases a variety of physics topics from total internal reflection to electrostatics to non-Newtonian fluid dynamics, including the Kaye effect. The essential components of the demonstration include a vertical stream of liquid soap in which a laser pointer is internally reflected, and which subsequently hits an inclined plane. As the liquid soap, a non-Newtonian fluid, begins to accumulate into a pile, its shear properties change and the incoming fluid rebounds from the pile, forming striking parabolic arcs. We present here a readily reproducible and inexpensive version of a laser soap fountain.
A simple method to measure critical angles for high-sensitivity differential refractometry.
Zilio, S C
2012-01-16
A total internal reflection-based differencial refractometer, capable of measuring the real and imaginary parts of the complex refractive index in real time, is presented. The device takes advantage of the phase difference acquired by s- and p-polarized light to generate an easily detectable minimum at the reflected profile. The method allows to sensitively measuring transparent and turbid liquid samples.
Kim, Iltai; Kihm, Kenneth D
2010-02-01
Time-dependent and near-field nanoparticle concentrations are determined by correlating the surface plasmon resonance (SPR) reflectance intensities with the effective refractive index (ERI) of the nanofluid under evaporation. A critical angle measurement for total internal reflection identifies the ERI of the nanofluid at different nanoparticle concentrations. The corresponding SPR reflectance intensities correlate the nanofluidic ERI with the nanoparticle concentrations. Example applications for evaporating nanofluidic droplets containing 47 nmAl(2)O(3) particles demonstrate the feasibility of this new imaging tool for measuring time-resolved and full-field nanoparticle concentration profiles.
NASA Astrophysics Data System (ADS)
Yokley, Zachary
2013-04-01
The LENS detector uses an optically segmented 3D lattice, a scintillation lattice (SL), that channels light via total internal reflection from a scintillation event down channels parallel to the 3 primary Cartesian axes to the edge of the detector. This unique design provides spatial and temporal resolution required to distinguish the internal background of ^115In from the neutrino signal. Optical segmentation is achieved with Teflon films. Currently a 400 liter prototype, miniLENS, is being developed to demonstrate the internal background rejection techniques needed for LENS. This requires that miniLENS be shielded from external backgrounds from the surrounding materials and the photomultiplier tubes (PMTs). This shielding is provided by a water tank that surrounds miniLENS. In order to retain the channel information and separate the PMTs from the detector the LENS collaboration has developed light guides (LGs) made from multilayer films. These LGs transport light both by total internal and specular reflection providing an efficient means of coupling the SL through the water shield to the PMTs outside the water tank. This talk will discuss light transport in the SL as well as the design and construction of the LGs in the context of miniLENS.
Magnetic Snell's law and spin-wave fiber with Dzyaloshinskii-Moriya interaction
NASA Astrophysics Data System (ADS)
Yu, Weichao; Lan, Jin; Wu, Ruqian; Xiao, Jiang
2016-10-01
Spin waves are collective excitations propagating in the magnetic medium with ordered magnetizations. Magnonics, utilizing the spin wave (magnon) as an information carrier, is a promising candidate for low-dissipation computation and communication technologies. We discover that, due to the Dzyaloshinskii-Moriya interaction, the scattering behavior of the spin wave at a magnetic domain wall follows a generalized Snell's law, where two magnetic domains work as two different mediums. Similar to optical total reflection that occurs at water-air interfaces, spin waves may experience total reflection at the magnetic domain walls when their incident angle is larger than a critical value. We design a spin-wave fiber using a magnetic domain structure with two domain walls, and demonstrate that such a spin-wave fiber can transmit spin waves over long distances by total internal reflections, in analogy to an optical fiber.
Intra-Cavity Total Reflection For High Sensitivity Measurement Of Optical Properties
Pipino, Andrew Charles Rule
1999-11-16
An optical cavity resonator device is provided for conducting sensitive murement of optical absorption by matter in any state with diffraction-limited spatial resolution through utilization of total internal reflection within a high-Q (high quality, low loss) optical cavity. Intracavity total reflection generates an evanescent wave that decays exponentially in space at a point external to the cavity, thereby providing a localized region where absorbing materials can be sensitively probed through alteration of the Q-factor of the otherwise isolated cavity. When a laser pulse is injected into the cavity and passes through the evanescent state, an amplitude loss resulting from absorption is incurred that reduces the lifetime of the pulse in the cavity. By monitoring the decay of the injected pulse, the absorption coefficient of manner within the evanescent wave region is accurately obtained from the decay time measurement.
Intra-Cavity Total Reflection For High Sensitivity Measurement Of Optical Properties
Pipino, Andrew C. R.; Hudgens, Jeffrey W.
1999-08-24
An optical cavity resonator device is provided for conducting sensitive murement of optical absorption by matter in any state with diffraction-limited spatial resolution through utilization of total internal reflection within a high-Q (high quality, low loss) optical cavity. Intracavity total reflection generates an evanescent wave that decays exponentially in space at a point external to the cavity, thereby providing a localized region where absorbing materials can be sensitively probed through alteration of the Q-factor of the otherwise isolated cavity. When a laser pulse is injected into the cavity and passes through the evanescent state, an amplitude loss resulting from absorption is incurred that reduces the lifetime of the pulse in the cavity. By monitoring the decay of the injected pulse, the absorption coefficient of manner within the evanescent wave region is accurately obtained from the decay time measurement.
NASA Astrophysics Data System (ADS)
Fofanov, Ya A.
2009-06-01
A series of reflection resonances formed by the hyperfine components of the D2-lines in the spectrum of the natural mixture of rubidium isotopes is studied. Passages from resonantly frustrated total internal reflection to resonance Brewster reflection caused by the frequency tuning of the incident light are demonstrated experimentally. The contrast of the strongest refection resonances exceeds 500% at the moderate heating of reflecting cells. The intensity of the reflected light changes in this case by more than 20 times. A theory is developed which is based on a two-level model for resonance atoms and Fresnel formulas for reflection coefficients. Numerical calculations based on the proposed theory confirm main experimental results.
Internal reflection sensors with high angular resolution
NASA Astrophysics Data System (ADS)
Shavirin, I.; Strelkov, O.; Vetskous, A.; Norton-Wayne, L.; Harwood, R.
1996-07-01
We discuss the use of total internal reflection for the production of sensors with high angular resolution. These sensors are intended for measurement of the angle between a sensor's axis and the direction to a source of radiation or reflecting object. Sensors of this type are used in controlling the position of machine parts in robotics and industry, orienting space vehicles and astronomic devices in relation to the Sun, and as autocollimators for checking angles of deviation. This kind of sensor was used in the Apollo space vehicle some 20 years ago. Using photodetectors with linear and area CCD arrays has opened up new application possibilities for appropriately designed sensors. A generalized methodology is presented applicable to a wide range of tasks. Some modifications that can improve the performance of the basic design are described.
Allgeyer, Edward S; Sterling, Sarah M; Gunewardene, Mudalige S; Hess, Samuel T; Neivandt, David J; Mason, Michael D
2015-01-27
Understanding surface and interfacial lateral organization in material and biological systems is critical in nearly every field of science. The continued development of tools and techniques viable for elucidation of interfacial and surface information is therefore necessary to address new questions and further current investigations. Sum frequency spectroscopy (SFS) is a label-free, nonlinear optical technique with inherent surface specificity that can yield critical organizational information on interfacial species. Unfortunately, SFS provides no spatial information on a surface; small scale heterogeneities that may exist are averaged over the large areas typically probed. Over the past decade, this has begun to be addressed with the advent of SFS microscopy. Here we detail the construction and function of a total internal reflection (TIR) SFS spectral and confocal fluorescence imaging microscope directly amenable to surface investigations. This instrument combines, for the first time, sample scanning TIR-SFS imaging with confocal fluorescence microscopy.
Total Internal Reflection Microscopy (TIRM) as a nondestructive surface damage assessment tool
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liao, Z.M.; Cohen, S.J.; Taylor, J.R.
1994-10-01
An easy to use, nondestructive, method for evaluating subsurface damage in polished substrates has been established at LLNL. Subsurface damage has been related to laser damage in coated optical components used in high power, high repetition rate laser systems. Total Internal Reflection Microscopy (TIRM) has been shown to be a viable nondestructive technique in analyzing subsurface damage in optical components. A successful TIRM system has been established for evaluating subsurface damage on fused silica components. Laser light scattering from subsurface damage sites is collected through a Nomarski microscope. These images are then captured by a CCD camera for analysis onmore » a computer. A variety of optics, including components with intentional subsurface damage due to grinding and polishing, have been analyzed and their TIRM images compared to an existing destructive etching method. Methods for quantitative measurement of subsurface damage are also discussed.« less
Hu, Lei; Xie, Kang; Hu, Zhijia; Mao, Qiuping; Xia, Jiangying; Jiang, Haiming; Zhang, Junxi; Wen, Jianxiang; Chen, Jingjing
2018-04-02
Trapping light within cavities or waveguides in photonic crystals is an effective technology in modern integrated optics. Traditionally, cavities rely on total internal reflection or a photonic bandgap to achieve field confinement. Recent investigations have examined new localized modes that occur at a Dirac frequency that is beyond any complete photonic bandgap. We design Al 2 O 3 dielectric cylinders placed on a triangular lattice in air, and change the central rod size to form a photonic crystal microcavity. It is predicted that waves can be localized at the Dirac frequency in this device without photonic bandgaps or total internal reflections. We perform a theoretical analysis of this new wave localization and verify it experimentally. This work paves the way for exploring localized defect modes at the Dirac point in the visible and infrared bands, with potential applicability to new optical devices.
Label free imaging of cell-substrate contacts by holographic total internal reflection microscopy.
Mandracchia, Biagio; Gennari, Oriella; Marchesano, Valentina; Paturzo, Melania; Ferraro, Pietro
2017-09-01
The study of cell adhesion contacts is pivotal to understand cell mechanics and interaction at substrates or chemical and physical stimuli. We designed and built a HoloTIR microscope for label-free quantitative phase imaging of total internal reflection. Here we show for the first time that HoloTIR is a good choice for label-free study of focal contacts and of cell/substrate interaction as its sensitivity is enhanced in comparison with standard TIR microscopy. Finally, the simplicity of implementation and relative low cost, due to the requirement of less optical components, make HoloTIR a reasonable alternative, or even an addition, to TIRF microscopy for mapping cell/substratum topography. As a proof of concept, we studied the formation of focal contacts of fibroblasts on three substrates with different levels of affinity for cell adhesion. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Cyclic Colour Change in the Bearded Dragon Pogona vitticeps under Different Photoperiods
Fan, Marie; Stuart-Fox, Devi; Cadena, Viviana
2014-01-01
The ability to change colour rapidly is widespread among ectotherms and has various functions including camouflage, communication and thermoregulation. The process of colour change can occur as an aperiodic event or be rhythmic, induced by cyclic environmental factors or regulated by internal oscillators. Despite the importance of colour change in reptile ecology, few studies have investigated the occurrence of a circadian rhythm in lizard pigmentation. Additionally, although colour change also entails changes in near-infrared reflectance, which may affect thermoregulation, little research has examined this part of the spectrum. We tested whether the bearded dragon lizard, Pogona vitticeps, displays an endogenous circadian rhythm in pigmentation changes that could be entrained by light/dark (LD) cycles and how light affected the relative change in reflectance in both ultraviolet-visible and near-infrared spectra. We subjected 11 lizards to four photoperiodic regimens: LD 12∶12; LD 6∶18; LD 18∶6 and DD; and measured their dorsal skin reflectance at 3-hour intervals for 72 hours after a habituation period. A proportion of lizards displayed a significant rhythm under constant darkness, with maximum reflectance occurring in the subjective night. This endogenous rhythm synchronised to the different artificial LD cycles, with maximum reflectance occurring during dark phases, but did not vary in amplitude. In addition, the total ultraviolet-visible reflectance in relation to the total near-infrared reflectance was significantly higher during dark phases than during light phases. We conclude that P. vitticeps exhibits a circadian pigmentation rhythm of constant amplitude, regulated by internal oscillators and that can be entrained by light/dark cycles. PMID:25354192
Cyclic colour change in the bearded dragon Pogona vitticeps under different photoperiods.
Fan, Marie; Stuart-Fox, Devi; Cadena, Viviana
2014-01-01
The ability to change colour rapidly is widespread among ectotherms and has various functions including camouflage, communication and thermoregulation. The process of colour change can occur as an aperiodic event or be rhythmic, induced by cyclic environmental factors or regulated by internal oscillators. Despite the importance of colour change in reptile ecology, few studies have investigated the occurrence of a circadian rhythm in lizard pigmentation. Additionally, although colour change also entails changes in near-infrared reflectance, which may affect thermoregulation, little research has examined this part of the spectrum. We tested whether the bearded dragon lizard, Pogona vitticeps, displays an endogenous circadian rhythm in pigmentation changes that could be entrained by light/dark (LD) cycles and how light affected the relative change in reflectance in both ultraviolet-visible and near-infrared spectra. We subjected 11 lizards to four photoperiodic regimens: LD 12:12; LD 6:18; LD 18:6 and DD; and measured their dorsal skin reflectance at 3-hour intervals for 72 hours after a habituation period. A proportion of lizards displayed a significant rhythm under constant darkness, with maximum reflectance occurring in the subjective night. This endogenous rhythm synchronised to the different artificial LD cycles, with maximum reflectance occurring during dark phases, but did not vary in amplitude. In addition, the total ultraviolet-visible reflectance in relation to the total near-infrared reflectance was significantly higher during dark phases than during light phases. We conclude that P. vitticeps exhibits a circadian pigmentation rhythm of constant amplitude, regulated by internal oscillators and that can be entrained by light/dark cycles.
Social functioning and internalized stigma in individuals diagnosed with substance use disorder.
Can, Ganime; Tanrıverdi, Derya
2015-12-01
The aim of this descriptive study was to determine social functioning and internalized stigma in individuals with substance use disorder. The study sample consisted of 105 patients diagnosed with substance use disorder according to the DSM-IV-TR diagnostic criteria. A Descriptive Information Form, Internalized Stigma of Mental Illness Scale (ISMI) and Social Functioning Scale (SFS) were used for data collection. Average total SFS score of the patients was 103.25±25.09 points, indicating an intermediate level of social functioning. Average total ISMI score of patients was 2.92±0.48 points, reflecting a high level of internalized stigma. A negative significant association was observed between the internalized stigma levels and social functioning of patients. These results suggest that rehabilitation of substance users should include counseling services in order to reduce internal perception of stigma and improve their social functioning. Copyright © 2015 Elsevier Inc. All rights reserved.
Cost effective flat plate photovoltaic modules using light trapping
NASA Technical Reports Server (NTRS)
Bain, C. N.; Gordon, B. A.; Knasel, T. M.; Malinowski, R. L.
1981-01-01
Work in optical trapping in 'thick films' is described to form a design guide for photovoltaic engineers. A thick optical film can trap light by diffusive reflection and total internal reflection. Light can be propagated reasonably long distances compared with layer thicknesses by this technique. This makes it possible to conduct light from inter-cell and intra-cell areas now not used in photovoltaic modules onto active cell areas.
Precise optical observation of 0.5-GPa shock waves in condensed materials
NASA Astrophysics Data System (ADS)
Nagayama, Kunihito; Mori, Yasuhito
1999-06-01
Precision optical observation method was developed to study impact-generated high-pressure shock waves in condensed materials. The present method makes it possible to sensitively detect the shock waves of the relatively low shock stress around 0.5 GPa. The principle of the present method is based on the use of total internal reflection by triangular prisms placed on the free surface of a target assembly. When a plane shock wave arrives at the free surface, the light reflected from the prisms extinguishes instantaneously. The reason is that the total internal reflection changes to the reflection depending on micron roughness of the free surface after the shock arrival. The shock arrival at the bottom face of the prisms can be detected here by two kinds of methods, i.e., a photographic method and a gauge method. The photographic method is an inclined prism method of using a high-speed streak camera. The shock velocity and the shock tilt angle can be estimated accurately from an obtained streak photograph. While in the gauge method, an in-material PVDF stress gauge is combined with an optical prism-pin. The PVDF gauge records electrically the stress profile behind the shockwave front, and the Hugoniot data can be precisely measured by combining the prism pin with the PVDF gauge.
Refraction-reflection of electrons at lateral metallic interfaces
NASA Astrophysics Data System (ADS)
Kher-Elden, M. A.; El-Fattah, Z. M. Abd; Yassin, O.; El-Okr, M. M.
2017-11-01
Electron boundary element method (EBEM) has been employed to simulate electron refraction at the lateral interface between two homogenous metals featuring surface states characterized by isotropic constant energy surfaces. A decent agreement was achieved between the real-space EBEM simulations and the wave-space analysis obtained from electron plane wave expansion (EPWE) method. Calculations were performed for three different electron energies, being -0.05, -0.15, and -0.25 eV, where the reference energy is set to -0.4 eV, i.e., the band minimum of the Cu(111) surface state. For an interface separating two metals with the same effective mass (0.41 me) and a potential difference of 0.2 eV, we demonstrate that electrons with the first two energies exhibit refraction at the interface, following the Snell's law, and total internal reflections occur beyond energy-dependent critical angles, whereas for the third electron energy, a total internal reflection occurs at all incident angles. These findings were used to simulate optical elements such as convex lenses and possible guiding through perfect electron mirrors, in contrast to Bragg-based guiding. Given the varieties of possible means of manipulating the dispersion parameters via surface adsorbates and thin-film growth, the degree of electron refraction-reflection at metallic interfaces could be precisely tuned.
Unit and internal chain profiles of maca amylopectin.
Zhang, Ling; Li, Guantian; Yao, Weirong; Zhu, Fan
2018-03-01
Unit chain length distributions of amylopectin and its φ, β-limit dextrins, which reflect amylopectin internal structure from three maca starches, were determined by high-performance anion-exchange chromatography with pulsed amperometric detection after debranching, and the samples were compared with maize starch. The amylopectins exhibited average chain lengths ranging from 16.72 to 17.16, with ranges of total internal chain length, external chain length, and internal chain length of the maca amylopectins at 12.49 to 13.68, 11.24 to 11.89, and 4.27 to 4.48. The average chain length, external chain length, internal chain length, and total internal chain length were comparable in three maca amylopectins. Amylopectins of the three maca genotypes studied here presented no significant differences in their unit chain length profiles, but did show significant differences in their internal chain profiles. Additional genetic variations between different maca genotypes need to be studied to provide unit- and internal chain profiles of maca amylopectin. Copyright © 2017. Published by Elsevier Ltd.
The development of optical microscopy techniques for the advancement of single-particle studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marchuk, Kyle
2013-05-15
Single particle orientation and rotational tracking (SPORT) has recently become a powerful optical microscopy tool that can expose many molecular motions. Unfortunately, there is not yet a single microscopy technique that can decipher all particle motions in all environmental conditions, thus there are limitations to current technologies. Within, the two powerful microscopy tools of total internal reflection and interferometry are advanced to determine the position, orientation, and optical properties of metallic nanoparticles in a variety of environments. Total internal reflection is an optical phenomenon that has been applied to microscopy to produce either fluorescent or scattered light. The non-invasive far-fieldmore » imaging technique is coupled with a near-field illumination scheme that allows for better axial resolution than confocal microscopy and epi-fluorescence microscopy. By controlling the incident illumination angle using total internal reflection fluorescence (TIRF) microscopy, a new type of imaging probe called “non-blinking” quantum dots (NBQDs) were super-localized in the axial direction to sub-10-nm precision. These particles were also used to study the rotational motion of microtubules being propelled by the motor protein kinesin across the substrate surface. The same instrument was modified to function under total internal reflection scattering (TIRS) microscopy to study metallic anisotropic nanoparticles and their dynamic interactions with synthetic lipid bilayers. Utilizing two illumination lasers with opposite polarization directions at wavelengths corresponding to the short and long axis surface plasmon resonance (SPR) of the nanoparticles, both the in-plane and out-of-plane movements of many particles could be tracked simultaneously. When combined with Gaussian point spread function (PSF) fitting for particle super-localization, the binding status and rotational movement could be resolved without degeneracy. TIRS microscopy was also used to find the 3D orientation of stationary metallic anisotropic nanoparticles utilizing only long-axis SPR enhancement. The polarization direction of the illuminating light was rotated causing the relative intensity of p-polarized and s-polarized light within the evanescent field to change. The interaction of the evanescent field with the particles is dependent on the orientation of the particle producing an intensity curve. This curve and the in-plane angle can be compared with simulations to accurately determine the 3D orientation. Differential interference contrast (DIC) microscopy is another non-invasive far-field technique based upon interferometry that does not rely on staining or other contrast enhancing techniques. In addition, high numerical aperture condensers and objectives can be used to give a very narrow depth of field allowing for the optical tomography of samples, which makes it an ideal candidate to study biological systems. DIC microscopy has also proven itself in determining the orientation of gold nanorods in both engineered environments and within cells. Many types of nanoparticles and nanostructures have been synthesized using lithographic techniques on silicon wafer substrates. Traditionally, reflective mode DIC microscopes have been developed and applied to the topographical study of reflective substrates and the imaging of chips on silicon wafers. Herein, a laser-illuminated reflected-mode DIC was developed for studying nanoparticles on reflective surfaces.« less
The development of optical microscopy techniques for the advancement of single-particle studies
NASA Astrophysics Data System (ADS)
Marchuk, Kyle
Single particle orientation and rotational tracking (SPORT) has recently become a powerful optical microscopy tool that can expose many molecular motions. Unfortunately, there is not yet a single microscopy technique that can decipher all particle motions in all environmental conditions, thus there are limitations to current technologies. Within, the two powerful microscopy tools of total internal reflection and interferometry are advanced to determine the position, orientation, and optical properties of metallic nanoparticles in a variety of environments. Total internal reflection is an optical phenomenon that has been applied to microscopy to produce either fluorescent or scattered light. The non-invasive far-field imaging technique is coupled with a near-field illumination scheme that allows for better axial resolution than confocal microscopy and epi-fluorescence microscopy. By controlling the incident illumination angle using total internal reflection fluorescence (TIRF) microscopy, a new type of imaging probe called "non-blinking" quantum dots (NBQDs) were super-localized in the axial direction to sub-10-nm precision. These particles were also used to study the rotational motion of microtubules being propelled by the motor protein kinesin across the substrate surface. The same instrument was modified to function under total internal reflection scattering (TIRS) microscopy to study metallic anisotropic nanoparticles and their dynamic interactions with synthetic lipid bilayers. Utilizing two illumination lasers with opposite polarization directions at wavelengths corresponding to the short and long axis surface plasmon resonance (SPR) of the nanoparticles, both the in-plane and out-of-plane movements of many particles could be tracked simultaneously. When combined with Gaussian point spread function (PSF) fitting for particle super-localization, the binding status and rotational movement could be resolved without degeneracy. TIRS microscopy was also used to find the 3D orientation of stationary metallic anisotropic nanoparticles utilizing only long-axis SPR enhancement. The polarization direction of the illuminating light was rotated causing the relative intensity of p-polarized and s-polarized light within the evanescent field to change. The interaction of the evanescent field with the particles is dependent on the orientation of the particle producing an intensity curve. This curve and the in-plane angle can be compared with simulations to accurately determine the 3D orientation. Differential interference contrast (DIC) microscopy is another non-invasive far-field technique based upon interferometry that does not rely on staining or other contrast enhancing techniques. In addition, high numerical aperture condensers and objectives can be used to give a very narrow depth of field allowing for the optical tomography of samples, which makes it an ideal candidate to study biological systems. DIC microscopy has also proven itself in determining the orientation of gold nanorods in both engineered environments and within cells. Many types of nanoparticles and nanostructures have been synthesized using lithographic techniques on silicon wafer substrates. Traditionally, reflective mode DIC microscopes have been developed and applied to the topographical study of reflective substrates and the imaging of chips on silicon wafers. Herein, a laser-illuminated reflected-mode DIC was developed for studying nanoparticles on reflective surfaces.
NASA Astrophysics Data System (ADS)
Ribeiro, Jair Lúcio Prados
2018-01-01
We only became aware of the existence of bed prism spectacles when a student brought them to the classroom and asked us about how they work. The device proved to be a fertile source of curiosity among the students, and, to be properly understood, it required us to develop a comparison between reflection in a typical mirror and total internal reflection in a prism. In this article we explain the physics behind this unfamiliar device, supported by geometrical optics principles.
A study of muscular tissue of animal origin by reflection-spectroscopy methods
NASA Astrophysics Data System (ADS)
Plotnikova, L. V.; Nechiporenko, A. P.; Orekhova, S. M.; Plotnikov, P. P.; Ishevskii, A. L.
2017-06-01
A comparative analysis of the spectral characteristics of the surface of muscular tissue of animal origin (pork) and its main components has been performed by the methods of diffuse reflection electronic spectroscopy (DRES) and frustrated total internal reflection IR spectroscopy. The experiments have shown that the application of the DRES method makes it possible to detect more pronounced changes in the surface optical characteristics of muscular tissue and obtain electronic spectra containing information about the component composition of its main parts under successive extraction of sarcoplasmic materials, myofibrillar proteins of the actomyosin complex, and stroma mucopolysaccharides.
Beach, R.J.; Benett, W.J.
1994-04-26
A lensing duct to condense (intensify) light using a combination of front surface lensing and reflective waveguiding is described. The duct tapers down from a wide input side to a narrow output side, with the input side being lens-shaped and coated with an antireflective coating for more efficient transmission into the duct. The four side surfaces are uncoated, preventing light from escaping by total internal reflection as it travels along the duct (reflective waveguiding). The duct has various applications for intensifying light, such as in the coupling of diode array pump light to solid state lasing materials, and can be fabricated from inexpensive glass and plastic. 3 figures.
2005-01-01
Index IMS Ion Mobility Spectrometry IR Infrared IRE Internal Reflection Element KBr Potassium Bromide LOD Limit of Detection MS Mass Spectrometer NB...Kaiser Bryant, Master of Science in Public Health, 2005 Directed By: Peter T. LaPuma, LtCol, USAF, BSC Assistant Professor, Department of Prey Med and...hereby certifies that the use of any copyrighted material in the thesis manuscript entitled: Chemical Agent Identification Using Field-Based Attenuated
Carter, Amanda G; Creedy, Debra K; Sidebotham, Mary
2017-11-01
develop and test a tool designed for use by academics to evaluate pre-registration midwifery students' critical thinking skills in reflective writing. a descriptive cohort design was used. a random sample (n = 100) of archived student reflective writings based on a clinical event or experience during 2014 and 2015. a staged model for tool development was used to develop a fifteen item scale involving item generation; mapping of draft items to critical thinking concepts and expert review to test content validity; inter-rater reliability testing; pilot testing of the tool on 100 reflective writings; and psychometric testing. Item scores were analysed for mean, range and standard deviation. Internal reliability, content and construct validity were assessed. expert review of the tool revealed a high content validity index score of 0.98. Using two independent raters to establish inter-rater reliability, good absolute agreement of 72% was achieved with a Kappa coefficient K = 0.43 (p<0.0001). Construct validity via exploratory factor analysis revealed three factors: analyses context, reasoned inquiry, and self-evaluation. The mean total score for the tool was 50.48 (SD = 12.86). Total and subscale scores correlated significantly. The scale achieved good internal reliability with a Cronbach's alpha coefficient of .93. this study establishedthe reliability and validity of the CACTiM (reflection) for use by academics to evaluate midwifery students' critical thinking in reflective writing. Validation with large diverse samples is warranted. reflective practice is a key learning and teaching strategy in undergraduate Bachelor of Midwifery programmes and essential for safe, competent practice. There is the potential to enhance critical thinking development by assessingreflective writing with the CACTiM (reflection) tool to provide formative and summative feedback to students and inform teaching strategies. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
Cardoso Dos Santos, Marcelina; Vézy, Cyrille; Jaffiol, Rodolphe
2016-06-01
We recently proposed a straightforward fluorescence microscopy technique to study adhesion of Giant Unilamellar Vesicles. This technique is based on dual observations which combine epi-fluorescence microscopy and total internal reflection fluorescence (TIRF) microscopy: TIRF images are normalized by epi-fluorescence ones. By this way, it is possible to map the membrane/substrate separation distance with a nanometric resolution, typically ~20 nm, with a maximal working range of 300-400 nm. The purpose of this paper is to demonstrate that this technique is useful to quantify vesicle adhesion from ultra-weak to strong membrane-surface interactions. Thus, we have examined unspecific and specific adhesion conditions. Concerning unspecific adhesion, we have controlled the strength of electrostatic forces between negatively charged vesicles and various functionalized surfaces which exhibit a positive or a negative effective charge. Specific adhesion was highlighted with lock-and-key forces mediated by the well defined biotin/streptavidin recognition. Copyright © 2016 Elsevier B.V. All rights reserved.
Watch your step! A frustrated total internal reflection approach to forensic footwear imaging
NASA Astrophysics Data System (ADS)
Needham, J. A.; Sharp, J. S.
2016-02-01
Forensic image retrieval and processing are vital tools in the fight against crime e.g. during fingerprint capture. However, despite recent advances in machine vision technology and image processing techniques (and contrary to the claims of popular fiction) forensic image retrieval is still widely being performed using outdated practices involving inkpads and paper. Ongoing changes in government policy, increasing crime rates and the reduction of forensic service budgets increasingly require that evidence be gathered and processed more rapidly and efficiently. A consequence of this is that new, low-cost imaging technologies are required to simultaneously increase the quality and throughput of the processing of evidence. This is particularly true in the burgeoning field of forensic footwear analysis, where images of shoe prints are being used to link individuals to crime scenes. Here we describe one such approach based upon frustrated total internal reflection imaging that can be used to acquire images of regions where shoes contact rigid surfaces.
Forkey, Joseph N.; Quinlan, Margot E.; Goldman, Yale E.
2005-01-01
A new approach is presented for measuring the three-dimensional orientation of individual macromolecules using single molecule fluorescence polarization (SMFP) microscopy. The technique uses the unique polarizations of evanescent waves generated by total internal reflection to excite the dipole moment of individual fluorophores. To evaluate the new SMFP technique, single molecule orientation measurements from sparsely labeled F-actin are compared to ensemble-averaged orientation data from similarly prepared densely labeled F-actin. Standard deviations of the SMFP measurements taken at 40 ms time intervals indicate that the uncertainty for individual measurements of axial and azimuthal angles is ∼10° at 40 ms time resolution. Comparison with ensemble data shows there are no substantial systematic errors associated with the single molecule measurements. In addition to evaluating the technique, the data also provide a new measurement of the torsional rigidity of F-actin. These measurements support the smaller of two values of the torsional rigidity of F-actin previously reported. PMID:15894632
Watch your step! A frustrated total internal reflection approach to forensic footwear imaging.
Needham, J A; Sharp, J S
2016-02-16
Forensic image retrieval and processing are vital tools in the fight against crime e.g. during fingerprint capture. However, despite recent advances in machine vision technology and image processing techniques (and contrary to the claims of popular fiction) forensic image retrieval is still widely being performed using outdated practices involving inkpads and paper. Ongoing changes in government policy, increasing crime rates and the reduction of forensic service budgets increasingly require that evidence be gathered and processed more rapidly and efficiently. A consequence of this is that new, low-cost imaging technologies are required to simultaneously increase the quality and throughput of the processing of evidence. This is particularly true in the burgeoning field of forensic footwear analysis, where images of shoe prints are being used to link individuals to crime scenes. Here we describe one such approach based upon frustrated total internal reflection imaging that can be used to acquire images of regions where shoes contact rigid surfaces.
Wang, Jun; Fei, Bei; Geahlen, Robert L.
2010-01-01
Protein translocation, or the change in a protein’s location between different subcellular compartments, is a critical process by which intracellular proteins carry out their cellular functions. Aberrant translocation events contribute to various diseases ranging from metabolic disorders to cancer. In this study, we demonstrate the use of a newly developed single-cell tool, microfluidic total internal reflection fluorescence flow cytometry (TIRF-FC), for detecting both cytosol to plasma membrane and cytosol to nucleus translocations using the tyrosine kinase Syk and the transcription factor NF-κB as models. This technique detects fluorescent molecules at the plasma membrane and in the membrane-proximal cytosol in single cells. We were able to record quantitatively changes in the fluorescence density in the evanescent field associated with these translocation processes for large cell populations with single cell resolution. We envision that TIRF-FC will provide a new approach to explore the molecular biology and clinical relevance of protein translocations. PMID:20820633
NASA Astrophysics Data System (ADS)
Paulauskas, A.; Selskis, A.; Bukauskas, V.; Vaicikauskas, V.; Ramanavicius, A.; Balevicius, Z.
2018-01-01
Total internal reflection ellipsometry (TIRE) was utilized in its dynamic data acquisition mode to reveal the percentage of mercury present in an amalgam surface layer. In determining the optical constants of the amalgam film, the non-homogeneities of the formed surface layer were taken into account. The composition of the amalgam layer by percentage was determined using the EMA Bruggemann model for the analysis of the TIRE data. Regression results showed that amalgam layer consisted of mercury 16.00 ± 0.43% and gold 84.00 ± 0.43%. This real time TIRE analysis has shown that for these studies method can detect 0.6 ± 0.4% of mercury on a gold surface, proving that this is a suitable optical technique for obtaining real time readouts. The structural analysis of SEM and AFM have shown that the amalgam layer had a dendritic structure, which formation was determined by the weak adhesion of the gold atoms onto its surface.
Larson, Joshua; Kirk, Matt; Drier, Eric A.; O’Brien, William; MacKay, James F.; Friedman, Larry; Hoskins, Aaron
2015-01-01
Colocalization Single Molecule Spectroscopy (CoSMoS) has proven to be a useful method for studying the composition, kinetics, and mechanisms of complex cellular machines. Key to the technique is the ability to simultaneously monitor multiple proteins and/or nucleic acids as they interact with one another. Here we describe a protocol for constructing a CoSMoS micromirror Total Internal Reflection Fluorescence Microscope (mmTIRFM). Design and construction of a scientific microscope often requires a number of custom components and a significant time commitment. In our protocol, we have streamlined this process by implementation of a commercially available microscopy platform designed to accommodate the optical components necessary for a mmTIRFM. The mmTIRF system eliminates the need for machining custom parts by the end-user and facilitates optical alignment. Depending on the experience-level of the microscope builder, these time-savings and the following protocol can enable mmTIRF construction to be completed within two months. PMID:25188633
Larson, Joshua; Kirk, Matt; Drier, Eric A; O'Brien, William; MacKay, James F; Friedman, Larry J; Hoskins, Aaron A
2014-10-01
Colocalization single-molecule spectroscopy (CoSMoS) has proven to be a useful method for studying the composition, kinetics and mechanisms of complex cellular machines. Key to the technique is the ability to simultaneously monitor multiple proteins and/or nucleic acids as they interact with one another. Here we describe a protocol for constructing a CoSMoS micromirror total internal reflection fluorescence microscope (mmTIRFM). Design and construction of a scientific microscope often requires a number of custom components and a substantial time commitment. In our protocol, we have streamlined this process by implementation of a commercially available microscopy platform designed to accommodate the optical components necessary for an mmTIRFM. The mmTIRF system eliminates the need for machining custom parts by the end user and facilitates optical alignment. Depending on the experience level of the microscope builder, these time savings and the following protocol can enable mmTIRF construction to be completed within 2 months.
What is the Temporal Analog of Reflection and Refraction of Optical Beams?
Plansinis, B W; Donaldson, W R; Agrawal, G P
2015-10-30
It is shown numerically and analytically that when an optical pulse approaches a moving temporal boundary across which the refractive index changes, it undergoes a temporal equivalent of reflection and refraction of optical beams at a spatial boundary. The main difference is that the role of angles is played by changes in the frequency. The frequency dependence of the dispersion of the material in which the pulse is propagating plays a fundamental role in determining the frequency shifts experienced by the reflected and refracted pulses. Our analytic expressions for these frequency shifts allow us to find the condition under which an analog of total internal reflection may occur at the temporal boundary.
An Experimental Study of Electronic States at Metal-Dielectric Interfaces.
1981-03-13
COOH) ha been measured usang the frus. FURTAK, G.R. TROTT , and B.H. L00, Ames Lab.-USDOE* and tamted total interns) reflection technique. Enhancments...Klutznick, Secretary Luther H. Hodges, Jr., Deputy Secretary Jordan J. Baruch, Assistant Secretary for Productivity, Technology, and Innovation
Exciting surface plasmon polaritons in the Kretschmann configuration by a light beam
NASA Astrophysics Data System (ADS)
Vinogradov, A. P.; Dorofeenko, A. V.; Pukhov, A. A.; Lisyansky, A. A.
2018-06-01
We consider exciting surface plasmon polaritons in the Kretschmann configuration. Contrary to common belief, we show that a plane-wave incident at an angle greater than the angle of total internal reflection does not excite surface plasmon polaritons. These excitations do arise, however, if the incident light forms a narrow beam composed of an infinite number of plane waves. The surface plasmon polariton is formed at the geometrical edge of the beam as a result of interference of reflected plane waves.
Graphene-based magnetless converter of terahertz wave polarization
NASA Astrophysics Data System (ADS)
Melnikova, Veronica S.; Polischuk, Olga V.; Popov, Vyacheslav V.
2016-04-01
The polarization conversion of terahertz radiation by the periodic array of graphene nanoribbons located at the surface of a high-refractive-index dielectric substrate (terahertz prism) is studied theoretically. Giant polarization conversion at the plasmon resonance frequencies takes place without applying external DC magnetic field. It is shown that the total polarization conversion can be reached at the total internal reflection of THz wave from the periodic array of graphene nanoribbons even at room temperature.
NASA Astrophysics Data System (ADS)
Fontaine, Norman Henry
1997-10-01
Techniques which can be used to obtain depth-resolved information on the thermodynamics at polymer-polymer and polymer-wall interfaces, and of small molecule diffusion in polymers, are of particular interest to industry. Optical methods which are sensitive to molecular vibrations (such as internal reflection Raman spectroscopy) are advantageous because they can non- destructively probe molecular content, orientation, and polarity of the local environment in a sample. However, while optical internal reflection depth-profiling methods have been reported, they have never progressed beyond the demonstration stage. In this work, the theory and methodology of internal reflection spectroscopy are developed and optimized into a rigorous field-controlled spectroscopic technique. A novel asymmetric internal reflection element (IRE) is introduced which traps back-reflections, allowing precise evanescent and standing wave probe-field control in the sample for all angles of incidence. It is demonstrated that a Gaussian laser beam will best approximate an infinite homogeneous plane wave when the IRE/sample interface lies in the paraxial-Fraunhofer region (far- field) of the beam path. Calibration methods are presented, sources of systematic errors are identified, and the angular resolution limit (ARL) is introduced as a measure of the field control developed in a sample by any internal reflection method. A general model of Raman scattering and photon detection from multi-layer thin films is developed. A new and generalized operator based transfer matrix method is developed and applied to electromagnetic field and diffusion computations in multi-layer systems. Total internal reflection spectroscopy is extended to include sub-critical angles of incidence, where resonant field enhancements generate large and selective amplification of the probe-field intensity within the layers of the sample. Fitting these resonances to the model spectral intensities allows unique determination of the location of buried interfaces in micron-sized polymer multi-layers with nanometer scale precision and the refractive indices of the layers with precision of /Delta n/approx/pm 0.0001. The Raman active molecular content of each optically distinct layer of the film is determinable simultaneously with the optical properties. Resonant mode VAIRRS studies of poly(methyl methacrylate) films spun-cast from toluene and then dried under ambient conditions have shown evidence for toluene diffusion concurrent with a rotationally hindered relaxation of oriented ester side groups about the polymer backbone. Low temperature annealing (≈87oC) has shown evidence that this hindered rotational relaxation may be reversible. VAIRRS study of a polystyrene/poly(methyl methacrylate) bi-layer has detected evidence for toluene diffusion across the buried polymer-polymer interface.
ERIC Educational Resources Information Center
Smith, Robert M., Ed.; And Others
The 1970 edition of this handbook is an attempt to reflect the totality of adult education -- its background, function, objectives, and roles -- as a discipline and in American society. It is divided into three parts. Part I discusses forms, functions, and the future of adult education -- social setting and international dimension for adult…
Why Does the Goldfish Disappear in the Fishbowl?
ERIC Educational Resources Information Center
Zhu, Yuhua; Shi, Fengliang
2009-01-01
You may have observed that a small goldfish swimming in a spherical fishbowl can suddenly disappear. Why does this happen? The effect is due to total internal reflection. In this paper we find the locations of the fish and the observer's eye for which the fish cannot be seen.
High-Sensitivity Microwave Optics.
ERIC Educational Resources Information Center
Nunn, W. M., Jr.
1981-01-01
Describes a 3.33-cm wavelength (9 GHz) microwave system that achieves a high overall signal sensitivity and a well-collimated beam with moderate-size equipment. The system has been used to develop microwave versions of the Michelson interferometer, Bragg reflector, Brewster's law and total internal reflection, and Young's interference experiment.…
Analysis of thin-film polymers using attenuated total internal reflection-Raman microspectroscopy.
Tran, Willie; Tisinger, Louis G; Lavalle, Luis E; Sommer, André J
2015-01-01
Two methods commonly employed for molecular surface analysis and thin-film analysis of microscopic areas are attenuated total reflection infrared (ATR-IR) microspectroscopy and confocal Raman microspectroscopy. In the former method, the depth of the evanescent probe beam can be controlled by the wavelength of light, the angle of incidence, or the refractive index of the internal reflection element. Because the penetration depth is proportional to the wavelength of light, one could interrogate a smaller film thickness by moving from the mid-infrared region to the visible region employing Raman spectroscopy. The investigation of ATR Raman microspectroscopy, a largely unexplored technique available to Raman microspectroscopy, was carried out. A Renishaw inVia Raman microscope was externally modified and used in conjunction with a solid immersion lens (SIL) to perform ATR Raman experiments. Thin-film polymer samples were analyzed to explore the theoretical sampling depth for experiments conducted without the SIL, with the SIL, and with the SIL using evanescent excitation. The feasibility of micro-ATR Raman was examined by collecting ATR spectra from films whose thickness measured from 200 to 60 nm. Films of these thicknesses were present on a much thicker substrate, and features from the underlying substrate did not become visible until the thin film reached a thickness of 68 nm.
Nonintrusive measurement of the liquid refractive index by using properties of the cuvette wall.
Xu, Ming; Ren, Junpeng; Miao, Runcai; Zhang, Zongquan
2016-10-01
We present a method of nonintrusive measurement of the refractive index of a liquid in a glass cuvette, which uses some optical properties of the cuvette wall and the principle of total internal reflection. By coating a transmission-scattering paint layer on the outer surface of the cuvette, we transform an incident laser beam into a transmitted scattered light. When the transmitted scattered light reaches the interface between the container wall and the liquid inside, the light beams satisfying the condition of total internal reflection are reflected to the coating layer, automatically forming a circular dark pattern that is related to the refractive index of the liquid. Based on an analytic relation between the diameter of the circular dark pattern and the refractive index of the liquid, we devised a method of in situ nonintrusive refractive index measurement. We tested the effect of several parameters on the measuring accuracy and found that the optimal thickness of the transmission-scattering layer is in the range of 50-70 μm, and the aperture of the diaphragm should be in the range of 0.7-1.0 mm. We measured the refractive indices of ethanol, Coca Cola, and red wine, and achieved an accuracy of ±3×10-4 RIU (refractive index unit).
Simmert, Steve; Abdosamadi, Mohammad Kazem; Hermsdorf, Gero; Schäffer, Erik
2018-05-28
Optical tweezers combined with various microscopy techniques are a versatile tool for single-molecule force spectroscopy. However, some combinations may compromise measurements. Here, we combined optical tweezers with total-internal-reflection-fluorescence (TIRF) and interference-reflection microscopy (IRM). Using a light-emitting diode (LED) for IRM illumination, we show that single microtubules can be imaged with high contrast. Furthermore, we converted the IRM interference pattern of an upward bent microtubule to its three-dimensional (3D) profile calibrated against the optical tweezers and evanescent TIRF field. In general, LED-based IRM is a powerful method for high-contrast 3D microscopy.
What is the temporal analog of reflection and refraction of optical beams?
Plansinis, B. W.; Donaldson, W. R.; Agrawal, G. P.
2015-10-28
It is shown numerically and analytically that when an optical pulse approaches a moving temporal boundary across which the refractive index changes, it undergoes a temporal equivalent of reflection and refraction of optical beams at a spatial boundary. The main difference is that the role of angles is played by changes in the frequency. The frequency dependence of the dispersion of the material in which the pulse is propagating plays a fundamental role in determining the frequency shifts experienced by the reflected and refracted pulses. As a result, our analytic expressions for these frequency shifts allow us to find themore » condition under which an analog of total internal reflection may occur at the temporal boundary.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Polischuk, O. V., E-mail: polischuk.sfire@mail.ru; Melnikova, V. S.; Popov, V. V., E-mail: popov-slava@yahoo.co.uk
2016-11-15
The terahertz absorption spectrum in a periodic array of graphene nanoribbons located on the surface of a dielectric substrate with a high refractive index (terahertz prism) is studied theoretically. The total absorption of terahertz radiation is shown to occur in the regime of total internal reflection of the terahertz wave from the periodic array of graphene nanoribbons, at the frequencies of plasma oscillations in graphene, in a wide range of incidence angles of the external terahertz wave even at room temperature.
Temporal waveguides for optical pulses
Plansinis, Brent W.; Donaldson, William R.; Agrawal, Govind P.
2016-05-12
Here we discuss, temporal total internal reflection (TIR), in analogy to the conventional TIR of an optical beam at a dielectric interface, is the total reflection of an optical pulse inside a dispersive medium at a temporal boundary across which the refractive index changes. A pair of such boundaries separated in time acts as the temporal analog of planar dielectric waveguides. We study the propagation of optical pulses inside such temporal waveguides, both analytically and numerically, and show that the waveguide supports a finite number of temporal modes. We also discuss how a single-mode temporal waveguide can be created inmore » practice. In contrast with the spatial case, the confinement can occur even when the central region has a lower refractive index.« less
TRASER - Total Reflection Amplification of Spontaneous Emission of Radiation
Zachary, Christopher B.; Gustavsson, Morgan
2012-01-01
Background and Objective Light and lasers in medical therapy have made dramatic strides since their invention five decades ago. However, the manufacture of lasers can be complex and expensive which often makes treatments limited and costly. Further, no single laser will provide the correct parameters to treat all things. Hence, laser specialists often need multiple devices to practice their specialty. A new concept is described herein that has the potential to replace many lasers and light sources with a single ‘tunable’ device. Study Design/Material and Methods This device amplifies spontaneous emission of radiation by capturing and retaining photons through total internal reflection, hence the acronym Total Reflection Amplification of Spontaneous Emission of Radiation, or TRASER. Results Specific peaks of light can be produced in a reproducible manner with high peak powers of variable pulse durations, a large spot size, and high repetition rate. Conclusion Considering the characteristics and parameters of Traser technology, it is possible that this one device would likely be able to replace the pulsed dye laser and many other light based systems. PMID:22558261
Nguyen, Brandon T; Kim, Ryan S; Bretana, Maria E; Kegley, Eric; Schefler, Amy C
2018-02-01
To evaluate the association between traditional clinical high-risk features of uveal melanoma patients and gene expression profile (GEP). This was a retrospective, single-center, case series of patients with uveal melanoma. Eighty-three patients met inclusion criteria for the study. Patients were examined for the following clinical risk factors: drusen/retinal pigment epithelium (RPE) changes, vascularity on B-scan, internal reflectivity on A-scan, subretinal fluid (SRF), orange pigment, apical tumor height/thickness, and largest basal dimensions (LBD). A novel point system was created to grade the high-risk clinical features of each tumor. Further analyses were performed to assess the degree of association between GEP and each individual risk factor, total clinical risk score, vascularity, internal reflectivity, American Joint Committee on Cancer (AJCC) tumor stage classification, apical tumor height/thickness, and LBD. Of the 83 total patients, 41 were classified as GEP class 1A, 17 as class 1B, and 25 as class 2. The presence of orange pigment, SRF, low internal reflectivity and vascularity on ultrasound, and apical tumor height/thickness ≥ 2 mm were not statistically significantly associated with GEP class. Lack of drusen/RPE changes demonstrated a trend toward statistical association with GEP class 2 compared to class 1A/1B. LBD and advancing AJCC stage was statistically associated with higher GEP class. In this cohort, AJCC stage classification and LBD were the only clinical features statistically associated with GEP class. Clinicians should use caution when inferring the growth potential of melanocytic lesions solely from traditional funduscopic and ultrasonographic risk factors without GEP data.
Prism Foil from an LCD Monitor as a Tool for Teaching Introductory Optics
ERIC Educational Resources Information Center
Planinsic, Gorazd; Gojkosek, Mihael
2011-01-01
Transparent prism foil is part of a backlight system in LCD monitors that are widely used today. This paper describes the optical properties of the prism foil and several pedagogical applications suitable for undergraduate introductory physics level. Examples include experiments that employ refraction, total internal reflection, diffraction and…
Lens testing using total internal reflection holography
Hildebrand, Bernard P.
1976-12-14
Accurate, rapid and inexpensive testing and inspecting of lens surfaces tugh holographic means requiring no beamsplitters, mirrors or overpower optics, and wherein a hologram formed in accordance with one aspect of the invention contains the entire interferometer and serves as both a master and illuminating source for both concave and convex surfaces to be so tested.
NASA Astrophysics Data System (ADS)
Bae, Albert; Westendorf, Christian; Erlenkamper, Christoph; Galland, Edouard; Franck, Carl; Bodenschatz, Eberhard; Beta, Carsten
2010-03-01
Eukaryotic cell flattening is valuable for improving microscopic observations, ranging from bright field to total internal reflection fluorescence microscopy. In this talk, we will discuss traditional overlay techniques, and more modern, microfluidic based flattening, which provides a greater level of control. We demonstrate these techniques on the social amoebae Dictyostelium discoideum, comparing the advantages and disadvantages of each method.
Visualizing substructure of Ca2+ waves by total internal reflection fluorescence microscopy
NASA Astrophysics Data System (ADS)
Bai, Yongqiang; Tang, Aihui; Wang, Shiqiang; Zhu, Xing
2005-02-01
Total internal reflection fluorescence microscope is a new optical microscopic system based on near-field optical theory. Its character of illumination by evanescent wave, together with the great signal-to-noise ratio and temporal resolution achieved by high quality CCD, allows us to analyze the spatiotemporal details of local Ca2+ dynamics within the nanoscale microdomain surrounding different Ca2+ channels. We have recently constructed a versatile objective TIRFM equipped with a high numerical aperture (NA=1.45) objective. Using fluo-4 as the Ca2+ indicator, we visualized the near-membrane profiles of Ca2+ waves and elementary Ca2+ sparks generated by Ca2+ release channels in rat ventricular myocytes. Different from those detected using conventional and confocal microscopy, Ca2+ waves observed with TIRFM exhibited fine inhomogenous substructures composed of fluctuating Ca2+ sparks. The anfractuous routes of spark recruitment suggested that the propagation of Ca2+ waves is much more complicated than previously imagined. We believe that TIRFM will provide a unique tool for dissecting the microscopic mechanisms of intracellular Ca2+ signaling.
Refractive index profilometry using the total internally reflected light field.
Das, Tania; Bhattacharya, K
2017-11-20
A full-field polarization-based technique is presented for quantitative evaluation of the spatial distribution of the refractive index in macro and micro samples. The sample is mounted on a glass-air interface of a prism, illuminated by a linearly polarized collimated light beam, and two intensity frames are digitally recorded with specific orientations of an analyzer. The pair of intensity data frames captured with this simple setup is combined through an algorithm specially developed for the purpose, to yield the phase difference between the transverse electric and transverse magnetic components of the total internally reflected light field. The phase difference is then related to the refractive index of the sample. Experimental results for refractive index variations in a laser-etched glass plate and red blood corpuscles are presented. One of the salient features of the proposed technique is that the depth of measurement is dependent on the penetration depth of the sample's evanescent field, which is typically of the order of a few hundred nanometers, thereby facilitating refractive index measurements along a thin section of the sample.
Watson, Brianna R.; Yang, Bin; Xiao, Kai; ...
2015-07-29
The emergence of efficient hybrid organic-inorganic perovskite photovoltaic materials has caused the rapid development of a variety of preparation and processing techniques designed to maximize their performance. As processing methods continue to emerge, it is important to understand how the optical properties of these materials are affected on a microscopic scale. Here polarization resolved two-photon total internal reflectance microscopy (TIRFM) was used to probe changes in transition dipole moment orientation as a function of thermal annealing time in hybrid organic-inorganic lead iodide based perovskite (CH 3NH 3PbI 3) thin films on glass. These results show that as thermal annealing timemore » is increased the distribution of transition moments pointing out-of-plane decreases in favor of forming areas with increased in-plane orientations. As a result, it was also shown through the axial sensitivity of TIRFM that the surface topography is manifested in the signal intensity and can be used to survey aspects of morphology in coincidence with the optical properties of these films.« less
Nabok, Alexei; Tsargorodskaya, Anna; Davis, Frank; Higson, Séamus P J
2007-10-31
The adsorption of genomic DNA and subsequent interactions between adsorbed and solvated DNA was studied using a novel sensitive optical method of total internal reflection ellipsometry (TIRE), which combines spectroscopic ellipsometry with surface plasmon resonance (SPR). Single strands of DNA of two species of fish (herring and salmon) were electrostatically adsorbed on top of polyethylenimine films deposited upon gold coated glass slides. The ellipsometric spectra were recorded and data fitting utilized to extract optical parameters (thickness and refractive index) of adsorbed DNA layers. The further adsorption of single stranded DNA from an identical source, i.e. herring ss-DNA on herring ss-DNA or salmon ss-DNA on salmon ss-DNA, on the surface was observed to give rise to substantial film thickness increases at the surface of about 20-21 nm. Conversely adsorption of DNA from alternate species, i.e. salmon ss-DNA on herring ss-DNA or herring ss-DNA on salmon ss-DNA, yielded much smaller changes in thickness of 3-5 nm. AFM studies of the surface roughness of adsorbed layers were in line with the TIRE data.
Boehm, Elizabeth M.; Subramanyam, Shyamal; Ghoneim, Mohamed; Washington, M. Todd; Spies, Maria
2016-01-01
Large, dynamic macromolecular complexes play essential roles in many cellular processes. Knowing how the components of these complexes associate with one another and undergo structural rearrangements is critical to understanding how they function. Single-molecule total internal reflection fluorescence (TIRF) microscopy is a powerful approach for addressing these fundamental issues. In this article, we first discuss single-molecule TIRF microscopes and strategies to immobilize and fluorescently label macromolecules. We then review the use of single-molecule TIRF microscopy to study the formation of binary macromolecular complexes using one-color imaging and inhibitors. We conclude with a discussion of the use of TIRF microscopy to examine the formation of higher-order (i.e., ternary, quaternary, etc.) complexes using multi-color setups. The focus throughout this article is on experimental design, controls, data acquisition, and data analysis. We hope that single-molecule TIRF microscopy, which has largely been the province of specialists, will soon become as common in the tool box of biophysicists and biochemists as structural approaches has become today. PMID:27793278
NASA Astrophysics Data System (ADS)
Vlaeva, I.; Petkov, K.; Tasseva, J.; Todorov, R.; Yovcheva, T.; Sainov, S.
2010-12-01
We report the results of electric field influence on holographic recording in very thin chalcogenide glass films. The total internal reflection prism recording technique (Stetson's scheme) is applied for holographic recording. The main advantage of this scheme is the possibility of holographic recording in micro- and nanometer thick photosensitive materials. In the present work, 30 nm, 50 nm and 1.0 µm thick films are used. In the 1.0 µm thick film two slanted gratings are simultaneously recorded. In this recording geometry only one reconstructed beam is observed. The corona charging influence on the diffraction efficiency of the recorded gratings is investigated. A negative voltage of 5 kV is applied to the corona electrode (needle) prior to the holographic recording. The observed diffraction efficiency of charged samples is always higher in comparison with uncharged samples. The reconstructed beam intensity is monitored with a red (635 nm) semiconductor laser. The possible reason is an additional refractive index modulation due to the increase in polarization, caused by the electric charging.
NASA Astrophysics Data System (ADS)
Bali, Samir; Judge, Patrick; Phillip, Nathan; Boivin, Jordan; Scaffidi, Jonathan; Berberich, Jason; Bali, Lalit
2014-05-01
We have initiated a collaborative experimental research program that combines new advances in optical physics, field portable chemical analysis, and biosensing. Our goal is to discover and characterize new optical sensing methodologies in opaque, highly scattering (i.e., ``turbid'') media, and demonstrate new paradigms for optical sensing in research and industry. We have three specific objectives. First, we propose to fully characterize and validate a new model of total internal reflection (TIR) from highly turbid media thus enabling a first demonstration of non-invasive, in-situ, real-time particle sizing for the case of arbitrary scattering particle size-a holy grail in colloidal science. Second, we propose to implement a first demonstration of real-time non-invasive measurement of nanoparticle aggregation in highly turbid media. Third, we propose to use our new sensing methodology to demonstrate real-time in-situ label-free monitoring of molecular interactions and adsorption at surfaces. We gratefully acknowledge support from the American Chemical Society Petroleum Research Fund and Miami University's Interdisciplinary Roundtable Fund. We also gratefully acknowledge experimental help from the Miami University Instrumentation Laboratory.
Total Internal Reflection Ultrasonic Sensor for Detection of Subsurface Flaws: Proof of Concept
2010-01-01
34 Tv001 Ve group (ray) velocity of the elastic wave X1, X2, X3 crystallographic coordinates x, y, z Descartes ’ coordinates tied to the transducer y0...TeO2 prism. 1.2.1. Orientation of directions and planes of interest with respect to Descartes ’ and Spherical coordinates. 1.2.2. Reflection of the...spect to Descartes ’ and Spherical coordi- nates. , (1.2.1) lili uuv Γ=ρ 2 where ρ is the crystal density and the symmetrical second rank Christoffel
1×2 demultiplexer for a light waveguide communications system based on a holographic grating
NASA Astrophysics Data System (ADS)
Ren, Xuechang; Zhang, Xiangsu; Wang, Canhui; Liu, Shou
2009-05-01
2-channel multiplexer/demultiplexer (Muxer/Demuxer) is a key component for bidirectional data traffics applied for optical communication. Up to date various types of Muxer/Demuxer have been proposed and demonstrated. A grating coupler diffracts light into substrates or waveguides, along which light beam propagates by total internal reflection. In addition, one can exploit the dispersive and filtering characteristics of gratings, for dropping or separating one or several wavelengths from one another. When a laser beam containing two wavelengths is striking the surface of the grating with an incident angle within certain range, four diffracted beams will be generated. If two diffracted beams, corresponding to different wavelengths, meet the condition of total internal reflection, they will propagate inside the glass substrate (performs as a waveguide). While the third one cannot meet total reflection condition, and the last one should become the evanescent wave. Therefore it can separate two signals and couple signals to different waveguides. These functions are suited for WDM application and directional couplers. For convenience sake, the visible lights at 458nm and 633nm were used as the incident laser beams. To give a simple sample for 1×2 demultiplexing system, a holographic grating was recorded, with the period around 441nm which was chose discretionally within the certain range. The primary experimental results indicate that the two-wavelength signal can be separated and coupled into the respective waveguide as long as the grating is recorded and operated complying with the certain condition. The average insertion loss and crosstalk of the device were presented in this paper.
NASA Astrophysics Data System (ADS)
Davydov, B. L.
2006-05-01
New crystal anisotropic prisms for splitting orthogonally polarised components of laser radiation by large angles with minimal reflection losses caused by the Brewster refraction and total internal reflection of polarised waves from the crystal—air interface are considered and the method for their calculation is described. It is shown that, by assembling glue-free combinations of two or three prisms, thermally stable beamsplitters can be fabricated, which are free from the beam astigmatism and the wave dispersion of the output angles of the beams. The parameters and properties of new beamsplitters are presented in a convenient form in figures and tables.
NASA Astrophysics Data System (ADS)
Hull, J. R.
Since its introduction, the concept of nonimaging solar concentrators, as exemplified by the compound parabolic concentrator (CPC) design, has greatly enhanced the ability to collect solar energy efficiently in thermal and photovoltaic devices. When used as a primary concentrator, a CPC can provide significant concentration without the complication of a tracking mechanism and its associated maintenance problems. When used as a secondary, a CPC provides higher total concentration, or for a fixed concentration, tolerates greater tracking error in the primary.
Karabudak, Engin; Kas, Recep; Ogieglo, Wojciech; Rafieian, Damon; Schlautmann, Stefan; Lammertink, R G H; Gardeniers, Han J G E; Mul, Guido
2013-01-02
Attenuated total reflection-infrared (ATR-IR) spectroscopy is increasingly used to characterize solids and liquids as well as (catalytic) chemical conversion. Here we demonstrate that a piece of silicon wafer cut by a dicing machine or cleaved manually can be used as disposable internal reflection element (IRE) without the need for polishing and laborious edge preparation. Technical aspects, fundamental differences, and pros and cons of these novel disposable IREs and commercial IREs are discussed. The use of a crystal (the Si wafer) in a disposable manner enables simultaneous preparation and analysis of substrates and application of ATR spectroscopy in high temperature processes that may lead to irreversible interaction between the crystal and the substrate. As representative application examples, the disposable IREs were used to study high temperature thermal decomposition and chemical changes of polyvinyl alcohol (PVA) in a titania (TiO(2)) matrix and assemblies of 65-450 nm thick polystyrene (PS) films.
Playing with Light: Adventures in Optics and Spectroscopy for Honors and Majors General Chemistry
ERIC Educational Resources Information Center
van Staveren, Marie N.; Edwards, Kimberly D.; Apkarian, V. A.
2012-01-01
A lab was developed for use in an undergraduate honors and majors general chemistry laboratory to introduce students to optics, spectroscopy, and the underlying principles of quantum mechanics. This lab includes four mini-experiments exploring total internal reflection, the tunneling of light, spectra of sparklers and colored candles, and emission…
19 CFR 351.524 - Allocation of benefit to a particular time period.
Code of Federal Regulations, 2014 CFR
2014-04-01
... the benefits are received if the total amount approved under the subsidy program is less than 0.5... assets for the industry concerned as listed in the Internal Revenue Service's (“IRS”) 1977 Class Life... do not reasonably reflect the company-specific AUL or the country-wide AUL for the industry under...
Heterodyne holographic microscopy of gold particles.
Atlan, Michael; Gross, Michel; Desbiolles, Pierre; Absil, Emilie; Tessier, Gilles; Coppey-Moisan, Maïté
2008-03-01
We report experimental results on heterodyne holographic microscopy of subwavelength-size gold particles. The apparatus uses continuous green-laser illumination of the metal beads in a total internal reflection configuration for dark-field operation. Detection of the scattered light at the illumination wavelength on a charge-coupled-device array detector enables 3D localization of brownian particles in water.
ERIC Educational Resources Information Center
Aguiar, Carlos E.; Santos, Antonio, C. F.; Lopes, Eric B.; Santos, Walter S.
2013-01-01
A goldfish isn't always visible inside its fishbowl. If the fish gets sufficiently close to the bowl glass, it will disappear for certain angles of observation. In a recent paper in this journal, Zhu and Shi explained the effect in terms of total internal reflection. We show in what follows that the phenomenon involves some richer optics: a…
Veligdan, James Thomas
1997-01-01
An optical display includes a plurality of optical waveguides each including a cladding bound core for guiding internal display light between first and second opposite ends by total internal reflection. The waveguides are stacked together to define a collective display thickness. Each of the cores includes a heterogeneous portion defining a light scattering site disposed longitudinally between the first and second ends. Adjacent ones of the sites are longitudinally offset from each other for forming a longitudinal internal image display over the display thickness upon scattering of internal display light thereagainst for generating a display image. In a preferred embodiment, the waveguides and scattering sites are transparent for transmitting therethrough an external image in superposition with the display image formed by scattering the internal light off the scattering sites for defining a heads up display.
NASA Astrophysics Data System (ADS)
Wellenreuther, G.; Fittschen, U. E. A.; Achard, M. E. S.; Faust, A.; Kreplin, X.; Meyer-Klaucke, W.
2008-12-01
Total reflection X-ray fluorescence (TXRF) is a very promising method for the direct, quick and reliable multi-elemental quantification of trace elements in protein samples. With the introduction of an internal standard consisting of two reference elements, scandium and gallium, a wide range of proteins can be analyzed, regardless of their salt content, buffer composition, additives and amino acid composition. This strategy also enables quantification of matrix effects. Two potential issues associated with drying have been considered in this study: (1) Formation of heterogeneous residues of varying thickness and/or density; and (2) separation of the internal standard and protein during drying (which has to be prevented to allow accurate quantification). These issues were investigated by microbeam X-ray fluorescence (μXRF) with special emphasis on (I) the influence of sample support and (II) the protein / buffer system used. In the first part, a model protein was studied on well established sample supports used in TXRF, PIXE and XRF (Mylar, siliconized quartz, Plexiglas and silicon). In the second part we imaged proteins of different molecular weight, oligomerization state, bound metals and solubility. A partial separation of protein and internal standard was only observed with untreated silicon, suggesting it may not be an adequate support material. Siliconized quartz proved to be the least prone to heterogeneous drying of the sample and yielded the most reliable results.
An All-Dielectric Coaxial Waveguide.
Ibanescu; Fink; Fan; Thomas; Joannopoulos
2000-07-21
An all-dielectric coaxial waveguide that can overcome problems of polarization rotation and pulse broadening in the transmission of optical light is presented here. It consists of a coaxial waveguiding region with a low index of refraction, bounded by two cylindrical, dielectric, multilayer, omnidirectional reflecting mirrors. The waveguide can be designed to support a single mode whose properties are very similar to the unique transverse electromagnetic mode of a traditional metallic coaxial cable. The new mode has radial symmetry and a point of zero dispersion. Moreover, because the light is not confined by total internal reflection, the waveguide can guide light around very sharp corners.
Hageneder, Simone; Bauch, Martin; Dostalek, Jakub
2016-08-15
This paper investigates plasmonic amplification in two commonly used optical configurations for fluorescence readout of bioassays - epifluorescence (EPF) and total internal reflection fluorescence (TIRF). The plasmonic amplification in the EPF configuration was implemented by using crossed gold diffraction grating and Kretschmann geometry of attenuated total reflection method (ATR) was employed in the TIRF configuration. Identical assay, surface architecture for analyte capture, and optics for the excitation, collection and detection of emitted fluorescence light intensity were used in both TIRF and EPF configurations. Simulations predict that the crossed gold diffraction grating (EPF) can amplify the fluorescence signal by a factor of 10(2) by the combination of surface plasmon-enhanced excitation and directional surface plasmon-coupled emission in the red part of spectrum. This factor is about order of magnitude higher than that predicted for the Kretschmann geometry (TIRF) which only took advantage of the surface plasmon-enhanced excitation. When applied for the readout of sandwich interleukin 6 (IL-6) immunoassay, the plasmonically amplified EPF geometry designed for Alexa Fluor 647 labels offered 4-times higher fluorescence signal intensity compared to TIRF. Interestingly, both geometries allowed reaching the same detection limit of 0.4pM despite of the difference in the fluorescence signal enhancement. This is attributed to inherently lower background of fluorescence signal for TIRF geometry compared to that for EPF which compensates for the weaker fluorescence signal enhancement. The analysis of the inflammation biomarker IL-6 in serum at medically relevant concentrations and the utilization of plasmonic amplification for the fluorescence measurement of kinetics of surface affinity reactions are demonstrated for both EPF and TIRF readout. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Marcó P., L. M.; Jiménez, E.; Hernández C., E. A.; Rojas, A.; Greaves, E. D.
2001-11-01
The method of quantification using the Compton peak as an internal standard, developed in a previous work, was applied to the routine determination of Fe, Cu, Zn and Se in serum samples from normal individuals and cancer patients by total reflection X-ray fluorescence spectrometry. Samples were classified according to age and sex of the donor, in order to determine reference values for normal individuals. Results indicate that the Zn/Cu ratio and the Cu concentration could prove to be useful tools for cancer diagnosis. Significant differences in these parameters between the normal and cancer group were found for all age ranges. The multielemental character of the technique, coupled with the small amounts of sample required and the short analysis time make it a valuable tool in clinical analysis.
NASA Astrophysics Data System (ADS)
Hoshino, Akiyoshi; Fujioka, Kouki; Yamamoto, Mayu; Manabe, Noriyoshi; Yasuhara, Masato; Suzuki, Kazuo; Yamamoto, Kenji
2005-11-01
Immunological diagnostic methods have been widely performed and showed high performance in molecular and cellular biology, molecular imaging, and medical diagnostics. We have developed novel methods for the fluorescent labeling of several antibodies coupled with fluorescent nanocrystals QDs. In this study we demonstrated that two bacterial toxins, diphtheria toxin and tetanus toxin, were detected simultaneously in the same view field of a cover slip by using directly QD-conjugated antibodies. We have succeeded in detecting bacterial toxins by counting luminescent spots on the evanescent field with using primary antibody conjugated to QDs. In addition, each bacterial toxin in the mixture can be separately detected by single excitation laser with emission band pass filters, and simultaneously in situ pathogen quantification was performed by calculating the luminescent density on the surface of the cover slip. Our results demonstrate that total internal reflection fluorescence microscopy (TIRFM) enables us to distinguish each antigen from mixed samples and can simultaneously quantitate multiple antigens by QD-conjugated antibodies. Bioconjugated QDs could have great potentialities for in practical biomedical applications to develop various high-sensitivity detection systems.
Cheng, Jian; Chen, Mingjun; Liao, Wei; Wang, Haijun; Xiao, Yong; Li, Mingquan
2013-07-15
Micro-machining is the most promising method for KH(2)PO(4) crystal to mitigate the surface damage growth in high power laser system. In this work, spherical mitigation pit is fabricated by micro-milling with an efficient machining procedure. The light intensification caused by rear surface features before and after mitigation is numerically modeled based on the finite-difference time-domain method. The results indicate that the occurrence of total internal reflections should be responsible for the largest light intensification inside the crystal. For spherical pits after mitigation, the light intensification can be greatly alleviated by preventing the occurrence of total internal reflections. The light intensification caused by spherical mitigation pit is strongly dependent on the width-depth ratio and it is suggested that the width-depth ratio of spherical mitigation pit must be devised to be larger than 5.0 to achieve the minimal light intensification for the mitigation of surface damage growth. Laser damage tests for KH(2)PO(4) crystal validate that the laser damage resistance of initially damaged surface can be retrieved to near the level of ideal surface by replacing initial damage site with predesigned mitigation pit.
Universal Long-Range Nanometric Bending of Water by Light.
Verma, Gopal; Singh, Kamal P
2015-10-02
Resolving mechanical effects of light on fluids has fundamental importance with wide applications. Most experiments to date on optofluidic interface deformation exploited radiation forces exerted by normally incident lasers. However, the intriguing effects of photon momentum for any configuration, including the unique total internal reflection regime, where an evanescent wave leaks above the interface, remain largely unexplored. A major difficulty in resolving nanomechanical effects has been the lack of a sensitive detection technique. Here, we devise a simple setup whereby a probe laser produces high-contrast Newton-ring-like fringes from a sessile water drop. The mechanical action of the photon momentum of a pump beam modulates the fringes, thus allowing us to perform a direct noninvasive measurement of a nanometric bulge with sub-5-nm precision. Remarkably, a <10 nm difference in the height of the bulge due to different laser polarizations and nonlinear enhancement in the bulge near total internal reflection is isolated. In addition, the nanometric bulge is shown to extend far longer, 100 times beyond the pump spot. Our high precision data validate the century-old Minkowski theory for a general angle and offer potential for novel optofluidic devices and noncontact nanomanipulation strategies.
NASA Astrophysics Data System (ADS)
Weger, Lukas; Hoffmann-Jacobsen, Kerstin
2017-09-01
Fluorescence correlation spectroscopy (FCS) measures fluctuations in a (sub-)femtoliter volume to analyze the diffusive behavior of fluorescent particles. This highly sensitive method has proven to be useful for the analysis of dynamic biological systems as well as in chemistry, physics, and material sciences. It is routinely performed with commercial fluorescence microscopes, which provide a confined observation volume by the confocal technique. The evanescent wave of total internal reflectance (TIR) is used in home-built systems to permit a surface sensitive FCS analysis. We present a combined confocal and TIR-FCS setup which uses economic low-power pulsed diode lasers for excitation. Excitation and detection are coupled to time-correlated photon counting hardware. This allows simultaneous fluorescence lifetime and FCS measurements in a surface-sensitive mode. Moreover, the setup supports fluorescence lifetime correlation spectroscopy at surfaces. The excitation can be easily switched between TIR and epi-illumination to compare the surface properties with those in liquid bulk. The capabilities of the presented setup are demonstrated by measuring the diffusion coefficients of a free dye molecule, a labeled polyethylene glycol, and a fluorescent nanoparticle in confocal as well as in TIR-FCS.
Evanescent Field Based Photoacoustics: Optical Property Evaluation at Surfaces
Goldschmidt, Benjamin S.; Rudy, Anna M.; Nowak, Charissa A.; Tsay, Yowting; Whiteside, Paul J. D.; Hunt, Heather K.
2016-01-01
Here, we present a protocol to estimate material and surface optical properties using the photoacoustic effect combined with total internal reflection. Optical property evaluation of thin films and the surfaces of bulk materials is an important step in understanding new optical material systems and their applications. The method presented can estimate thickness, refractive index, and use absorptive properties of materials for detection. This metrology system uses evanescent field-based photoacoustics (EFPA), a field of research based upon the interaction of an evanescent field with the photoacoustic effect. This interaction and its resulting family of techniques allow the technique to probe optical properties within a few hundred nanometers of the sample surface. This optical near field allows for the highly accurate estimation of material properties on the same scale as the field itself such as refractive index and film thickness. With the use of EFPA and its sub techniques such as total internal reflection photoacoustic spectroscopy (TIRPAS) and optical tunneling photoacoustic spectroscopy (OTPAS), it is possible to evaluate a material at the nanoscale in a consolidated instrument without the need for many instruments and experiments that may be cost prohibitive. PMID:27500652
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gianotto, A.K.; Wichlacz, P.L.; Jolley, J.G.
1989-01-01
Thin films of copper (2.0 nm on germanium internal reflection elements (IREs) and 3.4 nm on germanium discs) were exposed to 10% gum arabic (aqueous solution), 2% alginic acid (aqueous solution), 1% bacterial culture supernatant (BCS, simulated seawater solution) and 0.5% Pseudomonas atlantica exopolymer (simulated seawater solution). The IREs were monitored in situ, in real time using fourier transform infrared/cylindrical internal reflection/attenuated total reflection spectroscopy as a function of time at ambient conditions. The discs were characterized (pre- and post-exposure) by x-ray photoelectron and Auger electron spectroscopies. Ancillary graphite furnace atomic absorption spectroscopy was used to monitor the removal processmore » of the copper thin film from the germanium substrates. Results indicate that Cu was oxidized by gum arabic, alginic acid and BCS. Furthermore, Cu was removed from the Cu/Ge interface by all four polymers. The Cu was found associated with the polymer solutions. 20 refs., 6 figs., 1 tab.« less
NASA Astrophysics Data System (ADS)
Afzal, Muhammad Hassan Bin
2015-05-01
Rainfall measurement is performed on regular basis to facilitate effectively the weather stations and local inhabitants. Different types of rain gauges are available with different measuring principle for rainfall measurement. In this research work, a novel optical rain sensor is designed, which precisely calculate the rainfall level according to rainfall intensity. This proposed optical rain sensor model introduced in this paper, which is basically designed for remote sensing of rainfall and it designated as R-ORMS (Remote Optical Rainfall Measurement sensor). This sensor is combination of some improved method of tipping bucket rain gauge and most of the optical hydreon rain sensor's principle. This optical sensor can detect the starting time and ending time of rain, rain intensity and rainfall level. An infrared beam from Light Emitting Diode (LED) through powerful convex lens can accurately determines the diameter of each rain drops by total internal reflection principle. Calculations of these accumulative results determine the rain intensity and rainfall level. Accurate rainfall level is determined by internal optical LED based sensor which is embedded in bucket wall. This internal sensor is also following the total internal reflection (TIR) principle and the Fresnel's law. This is an entirely novel design of optical sensing principle based rain sensor and also suitable for remote sensing rainfall level. The performance of this proposed sensor has been comprehensively compared with other sensors with similar attributes and it showed better and sustainable result. Future related works have been proposed at the end of this paper, to provide improved and enhanced performance of proposed novel rain sensor.
Developing a Value Framework: The Need to Reflect the Opportunity Costs of Funding Decisions.
Sculpher, Mark; Claxton, Karl; Pearson, Steven D
2017-02-01
A growing number of health care systems internationally use formal economic evaluation methods to support health care funding decisions. Recently, a range of organizations have been advocating forms of analysis that have been termed "value frameworks." There has also been a push for analytical methods to reflect a fuller range of benefits of interventions through multicriteria decision analysis. A key principle that is invariably neglected in current and proposed frameworks is the need to reflect evidence on the opportunity costs that health systems face when making funding decisions. The mechanisms by which opportunity costs are realized vary depending on the system's financial arrangements, but they always mean that a decision to fund a specific intervention for a particular patient group has the potential to impose costs on others in terms of forgone benefits. These opportunity costs are rarely explicitly reflected in analysis to support decisions, but recent developments to quantify benefits forgone make more appropriate analyses feasible. Opportunity costs also need to be reflected in decisions if a broader range of attributes of benefit is considered, and opportunity costs are a key consideration in determining the appropriate level of total expenditure in a system. The principles by which opportunity costs can be reflected in analysis are illustrated in this article by using the example of the proposed methods for value-based pricing in the United Kingdom. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Suppression of sun interference in the star sensor baffling stray light by total internal reflection
NASA Astrophysics Data System (ADS)
Kawano, Hiroyuki; Shimoji, Haruhiko; Yoshikawa, Shoji; Miyatake, Katsumasa; Hama, Kazumori; Nakamura, Shuji
2005-09-01
We have developed a star sensor as an experimental device onboard the SERVIS-1 satellite launched in October 2003. The in-orbit data have verified its fundamental performance. One of the advantages of our star sensor is that the baffle has a small length of 120 mm instead of 182 mm in the conventional two-stage baffle design. The key concepts for light shielding are total internal reflection phenomena inside a nearly half sphere (NHS) lens and scattering light control by gloss black paint. However, undesirable background noise by the sun outside of the field of view (FOV) was observed in the corner of the FOV in the orbital experiment. Ray trace simulations revealed that slight scattering light on the specular baffle wall entered the NHS lens and reached the corner of the image sensor through the multi-reflection path inside the lens. It was found that the stray light path can be shielded effectively if the diameter of the aperture under the NHS lens was reduced. We redesigned the baffle and evaluated the light shielding ability with our sun interference test facility on the ground, and confirmed that the stray light was reduced below the acceptable level. As a result, the light shielding technique which we have proposed was proved to be effective for a small-size baffle. The redesigned star sensor is planned to be installed as a main attitude sensor for the SERVIS-2 satellite scheduled to be launched in February 2008.
Use of prismatic films to control light distribution
NASA Technical Reports Server (NTRS)
Kneipp, K. G.
1994-01-01
Piping light for illumination purposes is a concept which has been around for a long time. In fact, it was the subject of an 1881 United States patent which proposed the use of mirrors inside a tube to reflect light from wall to wall down the tube. The use of conventional mirrors for this purpose, however, has not worked because mirrors do not reflect well enough. On the other hand, optical fibers composed of certain glasses or plastics are known to transport light much more efficiently. The light that enters is reflected back and forth within the walls of the fiber until it reaches the other end. This is possible by means of a principle known as 'total internal reflection'. No light escapes through the walls and very little is absorbed in the bulk of the fiber. However, while optical fibers are very efficient in transporting light, they are impractical for transporting large quantities of light. Lorne Whitehead, as a student at the University of British Columbia, recognized that prismatic materials could be used to create a 'prism light guide', a hollow structure that can efficiently transport large quantities of light. This invention is a pipe whose transparent walls are formed on the outside into precise prismatic facets. The facets are efficient total internal reflection mirrors which prevent light travelling down the guide from escaping. Very little light is absorbed by the pipe because light travels primarily in the air space within the hollow guide. And, because the guide is hollow, weight and cost factors are much more favorable than would be the case with very large solid fibers. Recent advances in precision micromachining, polymer processing, and certain other manufacturing technologies have made the development of OLF (Optical Lighting Film) possible. The process is referred to as 'microreplication' and has been found to have broad applicability in a number of diverse product areas.
Internal Waves in the East Australian Current
NASA Astrophysics Data System (ADS)
Alford, Matthew H.; Sloyan, Bernadette M.; Simmons, Harper L.
2017-12-01
Internal waves, which drive most ocean turbulence and add "noise" to lower-frequency records, interact with low-frequency current systems and topography in yet poorly known ways. Taking advantage of a heavily instrumented, 14 month mooring array, internal waves in the East Australian Current (EAC) are examined for the first time. Internal wave horizontal kinetic energy (HKE) is within a factor of 2 of the Garrett-Munk (1976) spectrum. Continuum internal waves, near-inertial waves, and internal tides together constitute a significant percentage of the total velocity variance. Mode-1 internal tide energy fluxes are southward and much smaller than energy times group velocity, consistent with reflection at the continental slope of incident waves generated from near New Caledonia and the Solomon Islands. Internal tide HKE is highly phase variable, consistent with refraction by the variable EAC. Mode-1 near-inertial wave energy fluxes are of comparable magnitude and are equatorward and episodic, consistent with generation by storms farther poleward. These processes are considered together in the complex environment of the EAC.
Adsorption of poly(ethylene glycol)-modified ribonuclease A to a poly(lactide-co-glycolide) surface.
Daly, Susan M; Przybycien, Todd M; Tilton, Robert D
2005-06-30
Protein adsorption is a source of variability in the release profiles of therapeutic proteins from biodegradable microspheres. We employ optical reflectometry and total internal reflection fluorescence to explore the extent and kinetics of ribonuclease A (RNase A) adsorption to spin-cast films of poly(lactide-co-glycolide) (PLG) and, in particular, to determine how covalent grafting of polyethylene glycol (PEG) to RNase A affects adsorption. Adsorption kinetics on PLG surfaces are surface-limited for RNase A but transport-limited for unconjugated PEG homopolymers and for PEG-modified RNase A, indicating that PEG anchors the conjugates to the surface during the transport-limited regime. PEG modification of RNase A decreases the total number of adsorbed molecules per unit area but increases the areal surface coverage because the grafted PEG chains exclude additional surface area. Total internal reflection fluorescence-based exchange measurements show that there is no exchange between adsorbed and solution-phase protein molecules. This indicates an unusually tenacious adsorption. Streaming current measurements indicate that the zeta potential of the PLG surface becomes increasingly negative as the film is exposed to water for several weeks, as expected. Aging of the PLG surface results in increased adsorption of unmodified RNase A but decreased adsorption of unconjugated PEG homopolymers and of PEG-RNase A conjugates, relative to the extent of adsorption on freshly prepared PLG surfaces. Adsorption results correlate well with an increase in the rate, total extent and preservation of bioactivity of RNase A released from PLG microspheres for the PEG-modified version of RNase A.
Nonimaging optics for nonuniform brightness distributions
NASA Astrophysics Data System (ADS)
Jenkins, David G.; Winston, Roland
1995-08-01
We present a general design method of nonimaging optics that obtains the highest possible concentration for a given absorber shape. This technique, which uses a complimentary edge ray to simplify the geometrical formulism, recovers familiar designs for flat phase space distributions, such as trumpets, and (theta) 1-(theta) 2 concentrators. This method is easy to use and handles diverse boundary conditions, such as reflection, satisfying total internal reflection or design within a material of graded index. Presented is a novel two-stage 2D solar collector with a fixed circular primary mirror and nonimaging secondary. This newly developed secondary gives a 25% improvement over conventional nonimaging concentrators.
An improved prism for use in laser resonators
NASA Astrophysics Data System (ADS)
Richards, J.
1981-08-01
The use of compound total internal reflection prisms rather than Porro prisms in polarisation coupled lasers is proposed. Performance advantages resulting from the use of these prisms include higher output without the need to bias the Pockels cell, ability to give a larger range of output coupling and independence of performance on the refractive index of the prism. In conventional Q-switched lasers the use of the prism at the Pockels cell end of the resonator instead of the usual 100% reflecting mirror also leads to some advantages including better hold-off, elimination of the need to bias the Pockels cell and insensitivity in one plane to angular misalignment.
Liquid crystal modulator with ultra-wide dynamic range and adjustable driving voltage.
Wang, Xing-jun; Huang, Zhang-di; Feng, Jing; Chen, Xiang-fei; Liang, Xiao; Lu, Yan-qing
2008-08-18
We demonstrated a reflective-type liquid crystal (LC) intensity modulator in 1550 nm telecomm band. An effective way to compensate the residual phase of a LC cell is proposed. With the adjustment of a true zero-order quarter wave plate and enhanced by total internal reflection induced birefringence, over 53 dB dynamic range was achieved, which is much desired for some high-end optical communication, infrared scene projection applications. In addition, the driving voltages were decreased and adjustable. Mechanical and spectral tolerance measurements show that our LC modulator is quite stable. Further applications of our experimental setup were discussed including bio-sensors and high speed modulators.
Khanfar, H K; Azzam, R M A
2009-09-20
An iterative procedure for the design of a polarizing beam splitter (PBS) that uses a form-birefringent, subwavelength-structured, one-dimensional photonic-crystal layer (SWS 1-D PCL) embedded in a high-index cubical prism is presented. The PBS is based on index matching and total transmission for the p polarization and total internal reflection for the s polarization at the prism-PCL interface at 45 degrees angle of incidence. A high extinction ratio in reflection (>50 dB) over the 4-12 microm IR spectral range is achieved using a SWS 1-D PCL of ZnTe embedded in a ZnS cube within an external field of view of +/-6.6 degrees and in the presence of grating filling factor errors of up to +/-10%. Comparable results, but with wider field of view, are also obtained with a Ge PCL embedded in a Si prism.
Zhao, Wenbo; Tu, Chongqi; Zhang, Hui; Fang, Yue; Wang, Guanglin; Liu, Lei
2014-04-01
To compare the effects and security between internal fixation and total hip arthroplasty for the patients in elderly with femoral neck fracture of displacement type through a meta analysis. Studies on comparison between internal fixation and total hip arthroplasty for the patients in the elderly with femoral neck fracture of displacement type were identified from PubMed database,EMBase database, COCHRANE library, CMB database, CNKI database and MEDLINE database. Data analysis were performed using Revman 5.2.6(the Cochrane Collaboration). Six published randomized controlled trials including 627 patients were suitable for the review, 286 cases in internal fixation group and 341 cases in total hip arthroplasty group. The results of meta analysis indicated that statistically significant difference were observed between the two groups in the quality of life which was reflected by the Harris scale (RR = 0.82, 95%CI:0.72-0.93, P < 0.05) , the reoperation rate (RR = 5.81, 95%CI:3.09-10.95, P < 0.05) and the major complications rate (RR = 3.60, 95%CI:2.29-5.67, P < 0.05) postoperatively. There were no difference in the mortality at 1 year and 5 years postoperatively(P > 0.05). For the patients with femoral neck fracture of displacement type in the elderly, there is no statistical difference between two groups in the mortality postoperatively. The quality of life and the security of operation in internal fixation group is worse than the total hip arthroplasty group.
NASA Technical Reports Server (NTRS)
Siegel, R.; Spuckler, C. M.
1992-01-01
The index of refraction can considerably influence the temperature distribution and radiative heat flow in semitransparent materials such as some ceramics. For external radiant heating, the refractive index influences the amount of energy transmitted into the interior of the material. Emission within a material depends on the square of its refractive index, and hence this emission can be many times that for a biackbody radiating into a vacuum. Since radiation exiting through an interface into a vacuum cannot exceed that of a blackbody, there is extensive reflection at the internal surface of an interface, mostly by total internal reflection. This redistributes energy within the layer and tends to make its temperature distribution more uniform. The purpose of the present analysis is to show that, for radiative equilibrium in a gray layer with diffuse interfaces, the temperature distribution and radiative heat flux for any index of refraction can be obtained very simply from the results for an index of refraction of unity. For the situation studied here, the layer is subjected to external radiative heating incident on each of its surfaces. The material emits, absorbs, and isotropically scatters radiation. For simplicity the index of refraction is unity in the medium surrounding the layer. The surfaces of the layer are assumed diffuse. This is probably a reasonable approximation for a ceramic layer that has not been polished. When transmitted radiation or radiation emitted from the interior reaches the inner surface of an interface, the radiation is diffused and some of it thereby placed into angular directions for which there is total internal reflection. This provides a trapping effect for retaining energy within the layer and tends to equalize its temperature distribution. An analysis of temperature distributions in absorbing-emitting layers, including index of refraction effects, was developed by Gardon (1958) to predict cooling and heat treating of glass plates. The interfaces were optically smooth; the resulting specular reflections were computed from the Fresnel reflection laws. This provides a somewhat different behavior than for diffuse interfaces. A similar application was for heating that occurs in a window of a re-entry vehicle (Fowle et al., 1969). A number of recent papers (Rokhsaz and Dougherty, 1989; Ping and Lallemand, 1989; Crosbie and Shieh, 1990) further examined the effects of Fresnel boundary reflections and nonunity refractive index. Other examples of analyses of both steady and transient heat transfer to single or multiple plane layers (Amlin and Korpela, 1979; Tarshis et al., 1969) have used diffuse assumptions at the interfaces as in the present study
Using the Missing Pin to Challenge Concepts of Refraction and Total Internal Reflection
ERIC Educational Resources Information Center
Tamang, Sushmika; Nopparatjamjomras, Suchai; Chitaree, Ratchapak; Nopparatjamjomras, Thasaneeya R.
2015-01-01
A container was placed on top of a piece of white paper, and a pin positioned so that it vertically touched an outside wall of the container. Students were asked to predict the image of the pin when it was observed from the top of the container. Two scenarios of either an empty container or a container completely filled with water were considered…
Simple Köhler homogenizers for image-forming solar concentrators
NASA Astrophysics Data System (ADS)
Zhang, Weiya; Winston, Roland
2010-08-01
By adding simple Köhler homogenizers in the form of aspheric lenses generated with an optimization approach, we solve the problems of non-uniform irradiance distribution and non-square irradiance pattern existing in some image-forming solar concentrators. The homogenizers do not require optical bonding to the solar cells or total internal reflection surface. Two examples are shown including a Fresnel lens based concentrator and a two-mirror aplanatic system.
6TH Saint Petersburg International Conference on Integrated Navigation Systems.
1999-10-01
France and Germany. RLGs of different architectures are considered: those with planar and nonplanar resonators, mirrors and totally reflecting...unless the possibility to use magnetic mirrors [21-25], based on the nonreciprocal transverse Kerr effect [23-25], for frequency separation of the...is in the plane of the magnetic mirror and normal to the plane of incidence. The magnetic mirror consists of a very thin transparent layer of
A Platform for Combined DNA and Protein Microarrays Based on Total Internal Reflection Fluorescence
Asanov, Alexander; Zepeda, Angélica; Vaca, Luis
2012-01-01
We have developed a novel microarray technology based on total internal reflection fluorescence (TIRF) in combination with DNA and protein bioassays immobilized at the TIRF surface. Unlike conventional microarrays that exhibit reduced signal-to-background ratio, require several stages of incubation, rinsing and stringency control, and measure only end-point results, our TIRF microarray technology provides several orders of magnitude better signal-to-background ratio, performs analysis rapidly in one step, and measures the entire course of association and dissociation kinetics between target DNA and protein molecules and the bioassays. In many practical cases detection of only DNA or protein markers alone does not provide the necessary accuracy for diagnosing a disease or detecting a pathogen. Here we describe TIRF microarrays that detect DNA and protein markers simultaneously, which reduces the probabilities of false responses. Supersensitive and multiplexed TIRF DNA and protein microarray technology may provide a platform for accurate diagnosis or enhanced research studies. Our TIRF microarray system can be mounted on upright or inverted microscopes or interfaced directly with CCD cameras equipped with a single objective, facilitating the development of portable devices. As proof-of-concept we applied TIRF microarrays for detecting molecular markers from Bacillus anthracis, the pathogen responsible for anthrax. PMID:22438738
Sonesson, Andreas W; Blom, Hans; Hassler, Kai; Elofsson, Ulla M; Callisen, Thomas H; Widengren, Jerker; Brismar, Hjalmar
2008-01-15
The aim of this work was to study the dynamics of proteins near solid surfaces in the presence or absence of competing surfactants by means of total internal reflection fluorescence correlation spectroscopy (TIR-FCS). Two different proteins were studied, bovine serum albumin (BSA) and Thermomyces lanuginosus lipase (TLL). A nonionic/anionic (C12E6/LAS) surfactant composition was used to mimic a detergent formulation and the surfaces used were C18 terminated glass. It was found that with increasing surfactant concentrations the term in the autocorrelation function (ACF) representing surface binding decreased. This suggested that the proteins were competed off the hydrophobic surface by the surfactant. When fitting the measured ACF to a model for surface kinetics, it was seen that with raised C12E6/LAS concentration, the surface interaction rate increased for both proteins. Under these experimental conditions this meant that the time the protein was bound to the surface decreased. At 10 microM C12E6/LAS the surface interaction was not visible for BSA, whereas it was still distinguishable in the ACF for TLL. This indicated that TLL had a higher affinity than BSA for the C18 surface. The study showed that TIR-FCS provides a useful tool to quantify the surfactant effect on proteins adsorption.
New light on ion channel imaging by total internal reflection fluorescence (TIRF) microscopy.
Yamamura, Hisao; Suzuki, Yoshiaki; Imaizumi, Yuji
2015-05-01
Ion channels play pivotal roles in a wide variety of cellular functions; therefore, their physiological characteristics, pharmacological responses, and molecular structures have been extensively investigated. However, the mobility of an ion channel itself in the cell membrane has not been examined in as much detail. A total internal reflection fluorescence (TIRF) microscope allows fluorophores to be imaged in a restricted region within an evanescent field of less than 200 nm from the interface of the coverslip and plasma membrane in living cells. Thus the TIRF microscope is useful for selectively visualizing the plasmalemmal surface and subplasmalemmal zone. In this review, we focused on a single-molecule analysis of the dynamic movement of ion channels in the plasma membrane using TIRF microscopy. We also described two single-molecule imaging techniques under TIRF microscopy: fluorescence resonance energy transfer (FRET) for the identification of molecules that interact with ion channels, and subunit counting for the determination of subunit stoichiometry in a functional channel. TIRF imaging can also be used to analyze spatiotemporal Ca(2+) events in the subplasmalemma. Single-molecule analyses of ion channels and localized Ca(2+) signals based on TIRF imaging provide beneficial pharmacological and physiological information concerning the functions of ion channels. Copyright © 2015 The Authors. Production and hosting by Elsevier B.V. All rights reserved.
Kolin, David L.; Ronis, David; Wiseman, Paul W.
2006-01-01
We present the theory and application of reciprocal space image correlation spectroscopy (kICS). This technique measures the number density, diffusion coefficient, and velocity of fluorescently labeled macromolecules in a cell membrane imaged on a confocal, two-photon, or total internal reflection fluorescence microscope. In contrast to r-space correlation techniques, we show kICS can recover accurate dynamics even in the presence of complex fluorophore photobleaching and/or “blinking”. Furthermore, these quantities can be calculated without nonlinear curve fitting, or any knowledge of the beam radius of the exciting laser. The number densities calculated by kICS are less sensitive to spatial inhomogeneity of the fluorophore distribution than densities measured using image correlation spectroscopy. We use simulations as a proof-of-principle to show that number densities and transport coefficients can be extracted using this technique. We present calibration measurements with fluorescent microspheres imaged on a confocal microscope, which recover Stokes-Einstein diffusion coefficients, and flow velocities that agree with single particle tracking measurements. We also show the application of kICS to measurements of the transport dynamics of α5-integrin/enhanced green fluorescent protein constructs in a transfected CHO cell imaged on a total internal reflection fluorescence microscope using charge-coupled device area detection. PMID:16861272
Evanescent excitation and emission in fluorescence microscopy.
Axelrod, Daniel
2013-04-02
Evanescent light-light that does not propagate but instead decays in intensity over a subwavelength distance-appears in both excitation (as in total internal reflection) and emission (as in near-field imaging) forms in fluorescence microscopy. This review describes the physical connection between these two forms as a consequence of geometrical squeezing of wavefronts, and describes newly established or speculative applications and combinations of the two. In particular, each can be used in analogous ways to produce surface-selective images, to examine the thickness and refractive index of films (such as lipid multilayers or protein layers) on solid supports, and to measure the absolute distance of a fluorophore to a surface. In combination, the two forms can further increase selectivity and reduce background scattering in surface images. The polarization properties of each lead to more sensitive and accurate measures of fluorophore orientation and membrane micromorphology. The phase properties of the evanescent excitation lead to a method of creating a submicroscopic area of total internal reflection illumination or enhanced-resolution structured illumination. Analogously, the phase properties of evanescent emission lead to a method of producing a smaller point spread function, in a technique called virtual supercritical angle fluorescence. Copyright © 2013 Biophysical Society. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Ash, William Mason, III
Total Internal Reflection Holographic Microscopy (TIRHM) combines near-field microscopy with digital holography to produce a new form of near-field phase microscopy. Using a prism in TIR as a near-field imager, the presence of microscopic organisms, cell-substrate interfaces, and adhesions, causes relative refractive index (RRI) and frustrated TIR (f-TIR) to modulate the object beam's evanescent wave phase front. Quantitative phase images of test specimens such as Amoeba proteus, Dictyostelium Discoideum and cells such as SKOV-3 ovarian cancer and 3T3 fibroblasts are produced without the need to introduce stains or fluorophores. The angular spectrum method of digital holography to compensate for tilt anamorphism due to the inclined TIR plane is also discussed. The results of this work conclusively demonstrate, for the first time, the integration of near-field microscopy with digital holography. The cellular images presented show a correlation between the physical extent of the Amoeba proteus plasma membrane and the adhesions that are quantitatively profiled by phase cross-sectioning of the holographic images obtained by digital holography. With its ability to quantitatively characterise cellular adhesion and motility, it is anticipated that TIRHM can be a tool for characterizing and combating cancer metastasis, as well as improving our understanding of morphogenesis and embryogenesis itself.
Detection of anthrax lef with DNA-based photonic crystal sensors
NASA Astrophysics Data System (ADS)
Zhang, Bailin; Dallo, Shatha; Peterson, Ralph; Hussain, Syed; Weitao, Tao; Ye, Jing Yong
2011-12-01
Bacillus anthracis has posed a threat of becoming biological weapons of mass destruction due to its virulence factors encoded by the plasmid-borne genes, such as lef for lethal factor. We report the development of a fast and sensitive anthrax DNA biosensor based on a photonic crystal structure used in a total-internal-reflection configuration. For the detection of the lef gene, a single-stranded DNA lef probe was biotinylated and immobilized onto the sensor via biotin-streptavidin interactions. A positive control, lef-com, was the complementary strand of the probe, while a negative control was an unrelated single-stranded DNA fragment from the 16S rRNA gene of Acinetobacter baumannii. After addition of the biotinylated lef probe onto the sensor, significant changes in the resonance wavelength of the sensor were observed, resulting from binding of the probe to streptavidin on the sensor. The addition of lef-com led to another significant increase as a result of hybridization between the two DNA strands. The detection sensitivity for the target DNA reached as low as 0.1 nM. In contrast, adding the unrelated DNAs did not cause an obvious shift in the resonant wavelength. These results demonstrate that detection of the anthrax lef by the photonic crystal structure in a total-internal-reflection sensor is highly specific and sensitive.
Simplified design of thin-film polarizing beam splitter using embedded symmetric trilayer stack.
Azzam, R M A
2011-07-01
An analytically tractable design procedure is presented for a polarizing beam splitter (PBS) that uses frustrated total internal reflection and optical tunneling by a symmetric LHL trilayer thin-film stack embedded in a high-index prism. Considerable simplification arises when the refractive index of the high-index center layer H matches the refractive index of the prism and its thickness is quarter-wave. This leads to a cube design in which zero reflection for the p polarization is achieved at a 45° angle of incidence independent of the thicknesses of the identical symmetric low-index tunnel layers L and L. Arbitrarily high reflectance for the s polarization is obtained at subwavelength thicknesses of the tunnel layers. This is illustrated by an IR Si-cube PBS that uses an embedded ZnS-Si-ZnS trilayer stack.
Catoptric electrodes: transparent metal electrodes using shaped surfaces.
Kik, Pieter G
2014-09-01
An optical electrode design is presented that theoretically allows 100% optical transmission through an interdigitated metallic electrode at 50% metal areal coverage. This is achieved by redirection of light incident on embedded metal electrode lines to an angle beyond that required for total internal reflection. Full-field electromagnetic simulations using realistic material parameters demonstrate 84% frequency-averaged transmission for unpolarized illumination across the entire visible spectral range using a silver interdigitated electrode at 50% areal coverage. The redirection is achieved through specular reflection, making it nonresonant and arbitrarily broadband, provided the electrode width exceeds the optical wavelength. These findings could significantly improve the performance of photovoltaic devices and optical detectors that require high-conductivity top contacts.
Single-Frequency Nd:YAG Ring Lasers with Corner Cube Prism
NASA Astrophysics Data System (ADS)
Wu, Ke-Ying; Yang, Su-Hui; Zhao, Chang-Ming; Wei, Guang-Hui
2000-10-01
We put forward another form of the non-planar ring lasers, in which the corner cube prism is the key element and the Nd:YAG crystal is used as a Porro prism to enclose the ring resonator. The phase shift due to the total internal reflections of the three differently orientated reflection planes of the corner cube prism, Faraday rotation in the Nd:YAG crystal placed in a magnetic field and the different output coupling in S and P polarization form an optical diode and enforce the single-frequency generating power. A round trip analysis of the polarization properties of the resonator is made by the evaluation of Jones matrix.
THz-wave sensing via pump and signal wave detection interacted with evanescent THz waves.
Akiba, Takuya; Kaneko, Naoya; Suizu, Koji; Miyamoto, Katsuhiko; Omatsu, Takashige
2013-09-15
We report a novel sensing technique that uses an evanescent terahertz (THz) wave, without detecting the THz wave directly. When a THz wave generated by Cherenkov phase matching via difference frequency generation undergoes total internal reflection, the evanescent THz wave is subject to a phase change and an amplitude decrease. The reflected THz wave, under the influence of the sample, interferes with the propagating THz wave and the changing electric field of the THz wave interacts with the electric field of the pump waves. We demonstrate a sensing technique for detecting changes in the electric field of near-infrared light, transcribed from changes in the electric field of a THz wave.
Toledo-Martín, Eva María; García-García, María Carmen; Font, Rafael; Moreno-Rojas, José Manuel; Gómez, Pedro; Salinas-Navarro, María; Del Río-Celestino, Mercedes
2016-07-01
The characterization of internal (°Brix, pH, malic acid, total phenolic compounds, ascorbic acid and total carotenoid content) and external (color, firmness and pericarp wall thickness) pepper quality is necessary to better understand its possible applications and increase consumer awareness of its benefits. The main aim of this work was to examine the feasibility of using visible/near-infrared reflectance spectroscopy (VIS-NIRS) to predict quality parameters in different pepper types. Commercially available spectrophotometers were evaluated for this purpose: a Polychromix Phazir spectrometer for intact raw pepper, and a scanning monochromator for freeze-dried pepper. The RPD values (ratio of the standard deviation of the reference data to the standard error of prediction) obtained from the external validation exceeded a value of 3 for chlorophyll a and total carotenoid content; values ranging between 2.5 < RPD < 3 for total phenolic compounds; between 1.5 < RPD <2.5 for °Brix, pH, color parameters a* and h* and chlorophyll b; and RPD values below 1.5 for fruit firmness, pericarp wall thickness, color parameters C*, b* and L*, vitamin C and malic acid content. The present work has led to the development of multi-type calibrations for pepper quality parameters in intact and freeze-dried peppers. The majority of NIRS equations obtained were suitable for screening purposes in pepper breeding programs. Components such as pigments (xanthophyll, carotenes and chlorophyll), glucides, lipids, cellulose and water were used by modified partial least-squares regression for modeling the predicting equations. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.
Lindelow, M; Hardy, R; Rodgers, B
1997-01-01
OBJECTIVES: The psychiatric symptom frequency (PSF) scale was developed to assess symptoms of anxiety and depression (i.e. affective symptoms) experienced over the past year in the general population. This study aimed to examine the distribution of PSF scores, internal consistency, and factor structure and to investigate relationships between total scores for this scale and other indicators of poor mental health. PARTICIPANTS: The Medical Research Council national survey of health and development, a class stratified cohort study of men and women followed up from birth in 1946, with the most recent interview at age 43 when the PSF scale was administered. MAIN RESULTS: The PSF scale showed high internal consistency between the 18 items (Cronbach's alpha = 0.88). Ratings on items of the scale reflected one predominant factor, incorporating both depression and anxiety, and two additional factors of less statistical importance, one reflecting sleep problems and the other panic and situational anxiety. Total scores were calculated by adding 18 items of the scale, and high total scores were found to be strongly associated with reports of contact with a doctor or other health professional and use of prescribed medication for "nervous or emotional trouble or depression," and with suicidal ideas. CONCLUSIONS: The PSF is a useful and valid scale for evaluating affective symptoms in the general population. It is appropriate for administration by lay interviewers with minimal training, is relatively brief, and generates few missing data. The total score is a flexible measure which can be used in continuous or binary form to suit the purposes of individual investigations, and provides discrimination at lower as well as upper levels of symptom severity. PMID:9425466
Optimum Solar Conversion Cell Configurations
NASA Technical Reports Server (NTRS)
Chen, Bin (Inventor)
2015-01-01
Methods for maximizing a fraction of light energy absorbed in each of three classes of light concentrators (rectangular parallelepipeds, paraboloids and prisms) by choice of incident angle of radiation and of one or more geometrical or physical parameters (absorber thickness, paraboloid dimensions, location of paraboloid focus, prism angles, concentrator material, cladding, prism angles, etc.). Alternatively, the light energy absorbed plus the light energy that escapes through non-total internal reflection within the light concentrator can be minimized.
Using Video Records to Mediate Teaching Interns' Critical Reflection
ERIC Educational Resources Information Center
Scott, Sarah E.; Kucan, Linda; Correnti, Richard; Miller, Leigh A.
2013-01-01
In this study we investigated how the use of video records in a literacy methods course supports the development of reflective practitioners when video is a core element of the course design. Specifically, we detail how interns' video-based reflections provide evidence that the use of video records of teaching interns' promotes the development of…
NASA Astrophysics Data System (ADS)
Zhu, Keyong; Huang, Yong; Pruvost, Jeremy; Legrand, Jack; Pilon, Laurent
2017-06-01
This study aims to quantify systematically the effect of non-absorbing cap-shaped droplets condensed on the backside of transparent windows on their directional-hemispherical transmittance and reflectance. Condensed water droplets have been blamed to reduce light transfer through windows in greenhouses, solar desalination plants, and photobioreactors. Here, the directional-hemispherical transmittance was predicted by Monte Carlo ray-tracing method. For the first time, both monodisperse and polydisperse droplets were considered, with contact angle between 0 and 180°, arranged either in an ordered hexagonal pattern or randomly distributed on the window backside with projected surface area coverage between 0 and 90%. The directional-hemispherical transmittance was found to be independent of the size and spatial distributions of the droplets. Instead, it depended on (i) the incident angle, (ii) the optical properties of the window and droplets, and on (iii) the droplet contact angle and (iv) projected surface area coverage. In fact, the directional-hemispherical transmittance decreased with increasing incident angle. Four optical regimes were identified in the normal-hemispherical transmittance. It was nearly constant for droplet contact angles either smaller than the critical angle θcr (predicted by Snell's law) for total internal reflection at the droplet/air interface or larger than 180°-θcr. However, between these critical contact angles, the normal-hemispherical transmittance decreased rapidly to reach a minimum at 90° and increased rapidly with increasing contact angles up to 180°-θcr. This was attributed to total internal reflection at the droplet/air interface which led to increasing reflectance. In addition, the normal-hemispherical transmittance increased slightly with increasing projected surface area coverage for contact angle was smaller than θcr. However, it decreased monotonously with increasing droplet projected surface area coverage for contact angle larger than θcr. These results can be used to select the material or surface coating with advantageous surface properties for applications when dropwise condensation may otherwise have a negative effect on light transmittance.
Effect of reflection losses on stationary dielectric-filled nonimaging concentrators
NASA Astrophysics Data System (ADS)
Madala, Srikanth; Boehm, Robert F.
2016-10-01
The effect of Fresnel reflection and total internal reflection (TIR) losses on the performance parameters in refractive solar concentrators has often been downplayed because most refractive solar concentrators are traditionally the imaging type, yielding a line or point image on the absorber surface when solely interacted with paraxial etendue ensured by solar tracking. Whereas, with refractive-type nonimaging solar concentrators that achieve two-dimensional (rectangular strip) focus or three-dimensional (circular or elliptical) focus through interaction with both paraxial and nonparaxial etendue within the acceptance angle, the Fresnel reflection and TIR losses are significant as they will affect the performance parameters and, thereby, energy collection. A raytracing analysis has been carried out to illustrate the effects of Fresnel reflection and TIR losses on four different types of stationary dielectric-filled nonimaging concentrators, namely V-trough, compound parabolic concentrator, compound elliptical concentrator, and compound hyperbolic concentrator. The refractive index (RI) of a dielectric fill material determines the acceptance angle of a solid nonimaging collector. Larger refractive indices yield larger acceptance angles and, thereby, larger energy collection. However, they also increase the Fresnel reflection losses. This paper also assesses the relative benefit of increasing RI from an energy collection standpoint.
FTIR Study of ATP-Induced Changes in Na+/K+-ATPase from Duck Supraorbital Glands
Pratap, Promod R.; Dediu, Oana; Nienhaus, G. Ulrich
2003-01-01
The Na+/K+-ATPase uses energy from the hydrolysis of ATP to pump Na+ ions out of and K+ ions into the cell. ATP-induced conformational changes in the protein have been examined in the Na+/K+-ATPase isolated from duck supraorbital salt glands using Fourier transform infrared spectroscopy. Both standard transmission and attenuated total internal reflection sample geometries have been employed. Under transmission conditions, enzyme at 75 mg/ml was incubated with dimethoxybenzoin-caged ATP. ATP was released by flashing with a UV laser pulse at 355 nm, which resulted in a large change in the amide I band. The absorbance at 1659 cm−1 decreased with a concomitant increase in the absorbance at 1620 cm−1. These changes are consistent with a partial conversion of protein secondary structure from α-helix to β-sheet. The changes were ∼8% of the total absorbance, much larger than those seen with other P-type ATPases. Using attenuated total internal reflection Fourier transform infrared spectroscopy, the decrease in absorbance at ∼1650 cm−1 was titrated with ATP, and the titration midpoint K0.5 was determined under different ionic conditions. In the presence of metal ions (Na+, Na+ and K+, or Mg2+), K0.5 was on the order of a few μM. In the absence of these ions, K0.5 was an order of magnitude lower (0.1 μM), indicating a higher apparent affinity. This effect suggests that the equilibrium for the ATP-induced conformational changes is dependent on the presence of metal ions. PMID:14645062
Lucena, Rafael; Cárdenas, Soledad; Gallego, Mercedes; Valcárcel, Miguel
2006-03-01
Monitoring the exhaustion of alkaline degreasing baths is one of the main aspects in metal mechanizing industrial process control. The global level of surfactant, and mainly grease, can be used as ageing indicators. In this paper, an attenuated total reflection-Fourier transform infrared (ATR-FTIR) membrane-based sensor is presented for the determination of these parameters. The system is based on a micro-liquid-liquid extraction of the analytes through a polymeric membrane from the aqueous to the organic solvent layer which is in close contact with the internal reflection element and continuously monitored. Samples are automatically processed using a simple, robust sequential injection analysis (SIA) configuration, on-line coupled to the instrument. The global signal obtained for both families of compounds are processed via a multivariate calibration technique (partial least squares, PLS). Excellent correlation was obtained for the values given by the proposed method compared to those of the gravimetric reference one with very low error values for both calibration and validation.
Nakano, Hideki; Kodama, Takayuki; Ukai, Kazumasa; Kawahara, Satoru; Horikawa, Shiori; Murata, Shin
2018-01-01
In this study, we aimed to (1) translate the English version of the Kinesthetic and Visual Imagery Questionnaire (KVIQ), which assesses motor imagery ability, into Japanese, and (2) investigate the reliability and validity of the Japanese KVIQ. We enrolled 28 healthy adults in this study. We used Cronbach’s alpha coefficients to assess reliability reflected by the internal consistency. Additionally, we assessed validity reflected by the criterion-related validity between the Japanese KVIQ and the Japanese version of the Movement Imagery Questionnaire-Revised (MIQ-R) with Spearman’s rank correlation coefficients. The Cronbach’s alpha coefficients for the KVIQ-20 were 0.88 (Visual) and 0.91 (Kinesthetic), which indicates high reliability. There was a significant positive correlation between the Japanese KVIQ-20 (Total) and the Japanese MIQ-R (Total) (r = 0.86, p < 0.01). Our results suggest that the Japanese KVIQ is an assessment that is a reliable and valid index of motor imagery ability. PMID:29724042
Nakano, Hideki; Kodama, Takayuki; Ukai, Kazumasa; Kawahara, Satoru; Horikawa, Shiori; Murata, Shin
2018-05-02
In this study, we aimed to (1) translate the English version of the Kinesthetic and Visual Imagery Questionnaire (KVIQ), which assesses motor imagery ability, into Japanese, and (2) investigate the reliability and validity of the Japanese KVIQ. We enrolled 28 healthy adults in this study. We used Cronbach’s alpha coefficients to assess reliability reflected by the internal consistency. Additionally, we assessed validity reflected by the criterion-related validity between the Japanese KVIQ and the Japanese version of the Movement Imagery Questionnaire-Revised (MIQ-R) with Spearman’s rank correlation coefficients. The Cronbach’s alpha coefficients for the KVIQ-20 were 0.88 (Visual) and 0.91 (Kinesthetic), which indicates high reliability. There was a significant positive correlation between the Japanese KVIQ-20 (Total) and the Japanese MIQ-R (Total) (r = 0.86, p < 0.01). Our results suggest that the Japanese KVIQ is an assessment that is a reliable and valid index of motor imagery ability.
Bueno, Justin; Sikirzhytski, Vitali; Lednev, Igor K
2013-08-06
The ability to link a suspect to a particular shooting incident is a principal task for many forensic investigators. Here, we attempt to achieve this goal by analysis of gunshot residue (GSR) through the use of attenuated total reflectance (ATR) Fourier transform infrared spectroscopy (FT-IR) combined with statistical analysis. The firearm discharge process is analogous to a complex chemical process. Therefore, the products of this process (GSR) will vary based upon numerous factors, including the specific combination of the firearm and ammunition which was discharged. Differentiation of FT-IR data, collected from GSR particles originating from three different firearm-ammunition combinations (0.38 in., 0.40 in., and 9 mm calibers), was achieved using projection to latent structures discriminant analysis (PLS-DA). The technique was cross (leave-one-out), both internally and externally, validated. External validation was achieved via assignment (caliber identification) of unknown FT-IR spectra from unknown GSR particles. The results demonstrate great potential for ATR-FT-IR spectroscopic analysis of GSR for forensic purposes.
Titus, Jitto; Viennois, Emilie; Merlin, Didier; Perera, A. G. Unil
2016-01-01
This article describes a rapid, simple and cost-effective technique that could lead to a screening method for colitis without the need for biopsies or in vivo measurements. This screening technique includes the testing of serum using Attenuated Total Reflectance Fourier Transform Infrared (ATR-FTIR) spectroscopy for the colitis-induced increased presence of mannose. Chronic (Interleukin 10 knockout) and acute (Dextran Sodium Sulphate-induced) models for colitis are tested using the ATR-FTIR technique. Arthritis (Collagen Antibody Induced Arthritis) and metabolic syndrome (Toll like receptor 5 knockout) models are also tested as controls. The marker identified as mannose uniquely screens and distinguishes the colitic from the non-colitic samples and the controls. The reference or the baseline spectrum could be the pooled and averaged spectra of non-colitic samples or the subject's previous sample spectrum. This shows the potential of having individualized route maps of disease status, leading to personalized diagnosis and drug management. PMID:27094092
Gong, Xiangjun; Hua, Li; Wu, Chi; Ngai, To
2013-03-01
We present a novel microrheometer by incorporating magnetic tweezers in the total internal reflection microscopy (TIRM) that enables measuring of viscoelastic properties of materials near solid surface. An evanescent wave generated by a solid∕liquid interface in the TIRM is used as the incident light source in the microrheometer. When a probe particle (of a few micrometers diameter) moves near the interface, it can interact with the evanescent field and reflect its position with respect to the interface by the scattered light intensity. The exponential distance dependence of the evanescent field, on the one hand, makes this technique extremely sensitive to small changes from z-fluctuations of the probe (with a resolution of several nanometers), and on the other, it does not require imaging of the probe with high lateral resolution. Another distinct advantage is the high sensitivity in determining the z position of the probe in the absence of any labeling. The incorporated magnetic tweezers enable us to effectively manipulate the distance of the embedded particle from the interface either by a constant or an oscillatory force. The force ramp is easy to implement through a coil current ramp. In this way, the local viscous and elastic properties of a given system under different confinements can therefore be measured by resolving the near-surface particle motion. To test the feasibility of applying this microrheology to soft materials, we measured the viscoelastic properties of sucrose and poly(ethylene glycol) solutions and compared the results to bulk rheometry. In addition, we applied this technique in monitoring the structure and properties of deformable microgel particles near the flat surface.
Studies of the Reflection, Refraction and Internal Reflection of Light
ERIC Educational Resources Information Center
Lanchester, P. C.
2014-01-01
An inexpensive apparatus and associated experiments are described for studying the basic laws of reflection and refraction of light at an air-glass interface, and multiple internal reflections within a glass block. In order to motivate students and encourage their active participation, a novel technique is described for determining the refractive…
Hydrodynamic boundary condition of water on hydrophobic surfaces.
Schaeffel, David; Yordanov, Stoyan; Schmelzeisen, Marcus; Yamamoto, Tetsuya; Kappl, Michael; Schmitz, Roman; Dünweg, Burkhard; Butt, Hans-Jürgen; Koynov, Kaloian
2013-05-01
By combining total internal reflection fluorescence cross-correlation spectroscopy with Brownian dynamics simulations, we were able to measure the hydrodynamic boundary condition of water flowing over a smooth solid surface with exceptional accuracy. We analyzed the flow of aqueous electrolytes over glass coated with a layer of poly(dimethylsiloxane) (advancing contact angle Θ = 108°) or perfluorosilane (Θ = 113°). Within an error of better than 10 nm the slip length was indistinguishable from zero on all surfaces.
THz polariton laser using an intracavity Mg:LiNbO3 crystal with protective Teflon coating.
Ortega, Tiago A; Pask, Helen M; Spence, David J; Lee, Andrew J
2017-02-20
An enhancement in the performance of a THz polariton laser based on an intracavity magnesium-doped lithium niobate crystal (Mg:LiNbO3) in surface-emitted (SE) configuration is demonstrated resulting from the deposition of a protective Teflon coating on the total internal reflection surface of the crystal. In this cavity geometry the resonating fields undergo total internal reflection (TIR) inside the lithium niobate, and laser damage to that surface can be a limiting factor in performance. The protective layer prevents laser damage to the crystal surface, enabling higher pump power, yielding higher THz output power and wider frequency tuning range. With the unprotected crystal, narrow-band THz output tunable from 1.50 to 2.81 THz was produced, with maximum average output power of 20.1 µW at 1.76 THz for 4 W diode pump power (limited by laser damage to the crystal). With the Teflon coating, no laser damage to the crystal was observed, and the system produced narrow-band THz output tunable from 1.46 to 3.84 THz, with maximum average output power of 56.8 µW at 1.76 THz for 6.5 W diode pump power. This is the highest average output power and the highest diode-to-terahertz conversion efficiency ever reported for an intracavity terahertz polariton laser.
Label-free investigation of the effects of lithium niobate polarization on cell adhesion
NASA Astrophysics Data System (ADS)
Mandracchia, B.; Gennari, O.; Paturzo, M.; Grilli, S.; Ferraro, P.
2017-06-01
The determination of contact area is pivotal to understand how biomaterials properties influence cell adhesion. In particular, the influence of surface charges is well-known but still controversial, especially when new functional materials and methods are introduced. Here, we use for the first time Holographic Total Internal Reflection Microscopy (HoloTIRM) to study the influence of the spontaneous polarization of ferroelectric lithium niobate (LN) on the adhesion properties of fibroblast cells. The selective illumination of a very thin region directly above the substrate, achieved by Total Internal Reflection, provides high-contrast images of the contact regions. Holographic recording, on the other hand, allows for label-free quantitative phase imaging of the contact areas between cells and LN. Phase signal is more sensitive in the first 100nm and, thus more reliable in order to locate focal contacts. This work shows that cells adhering on negatively polarized LN present a significant increase of the contact area in comparison with cells adhering on the positively polarized LN substrate, as well as an intensification of contact vicinity. This confirms the potential of LN as a platform for investigating the role of charges on cellular processes. The similarity of cell adhesion behavior on negatively polarized LN and glass control also confirms the possibility to use LN as an active substrate without impairing cell behavior.
Single-Molecule Light-Sheet Imaging of Suspended T Cells.
Ponjavic, Aleks; McColl, James; Carr, Alexander R; Santos, Ana Mafalda; Kulenkampff, Klara; Lippert, Anna; Davis, Simon J; Klenerman, David; Lee, Steven F
2018-05-08
Adaptive immune responses are initiated by triggering of the T cell receptor. Single-molecule imaging based on total internal reflection fluorescence microscopy at coverslip/basal cell interfaces is commonly used to study this process. These experiments have suggested, unexpectedly, that the diffusional behavior and organization of signaling proteins and receptors may be constrained before activation. However, it is unclear to what extent the molecular behavior and cell state is affected by the imaging conditions, i.e., by the presence of a supporting surface. In this study, we implemented single-molecule light-sheet microscopy, which enables single receptors to be directly visualized at any plane in a cell to study protein dynamics and organization in live, resting T cells. The light sheet enabled the acquisition of high-quality single-molecule fluorescence images that were comparable to those of total internal reflection fluorescence microscopy. By comparing the apical and basal surfaces of surface-contacting T cells using single-molecule light-sheet microscopy, we found that most coated-glass surfaces and supported lipid bilayers profoundly affected the diffusion of membrane proteins (T cell receptor and CD45) and that all the surfaces induced calcium influx to various degrees. Our results suggest that, when studying resting T cells, surfaces are best avoided, which we achieve here by suspending cells in agarose. Copyright © 2018. Published by Elsevier Inc.
Fluorescent diamond nanoparticle as a probe of intracellular traffic in primary neurons in culture
NASA Astrophysics Data System (ADS)
Le, Xuan Loc; Lepagnol-Bestel, Aude-Marie; Adam, Marie-Pierre; Thomas, Alice; Dantelle, Géraldine; Chang, Cheng-Chun; Mohan, Nitin; Chang, Huan-Cheng; Treussart, François; Simonneau, Michel
2012-03-01
Neurons display dendritic spines plasticity and morphology anomalies in numerous psychiatric and neurodegenerative diseases. These changes are associated to abnormal dendritic traffic that can be evidenced by fluorescence microscopy. As a fluorescent probe we propose to use fluorescent diamond nanoparticles with size of < 50 nm. Color centers embedded inside the diamond nanoparticles are perfectly photostable emitters allowing for long-term tracking. Nanodiamond carbon surface is also well suited for biomolecule functionalization to target specific cellular compartments. We show that fluorescent nanodiamonds can be spontaneously internalized in neurons in culture and imaged by confocal and Total Internal Reflection (TIRF) microscopy with a high signal over background ratio.
Photovoltaic module with light reflecting backskin
Gonsiorawski, Ronald C [Danvers, MA
2007-07-03
A photovoltaic module comprises electrically interconnected and mutually spaced photovoltaic cells that are encapsulated by a light-transmitting encapsulant between a light-transparent front cover and a back cover, with the back cover sheet being an ionomer/nylon alloy embossed with V-shaped grooves running in at least two directions and coated with a light reflecting medium so as to provide light-reflecting facets that are aligned with the spaces between adjacent cells and oriented so as to reflect light falling in those spaces back toward said transparent front cover for further internal reflection onto the solar cells, whereby substantially all of the reflected light will be internally reflected from said cover sheet back to the photovoltaic cells, thereby increasing the current output of the module. The internal reflector improves power output by as much as 67%.
Azzam, R M A; De, A
2003-03-01
A symmetric achiral trilayer structure, which consists of a high-index center layer sandwiched between two identical low-index films and embedded in a high-index prism, is designed to produce equal and opposite quarter-wave retardation in reflection and transmission and equal throughput for the p and s polarization at oblique incidence. Such a device splits a beam of incident linearly polarized light into two orthogonally circularly polarized components of equal power that travel in different directions. A visible (633-nm) design that operates at a 60 degree angle of incidence and an infrared (10.6-microm) 45 degree cube design are presented. The spectral and angular sensitivities of the device are also considered.
ERIC Educational Resources Information Center
Le Cornu, Alison
2009-01-01
The study of the process of reflection has a dignified history. However, few have linked reflection to the development of the self in such a way that the form of reflection is understood to influence the resultant type of self. This article explores the process of reflection using a framework of meaning making, internalization, and externalization…
Pat, Lucio; Ali, Bassam; Guerrero, Armando; Córdova, Atl V.; Garduza, José P.
2016-01-01
Attenuated total reflectance-Fourier transform infrared spectrometry and chemometrics model was used for determination of physicochemical properties (pH, redox potential, free acidity, electrical conductivity, moisture, total soluble solids (TSS), ash, and HMF) in honey samples. The reference values of 189 honey samples of different botanical origin were determined using Association Official Analytical Chemists, (AOAC), 1990; Codex Alimentarius, 2001, International Honey Commission, 2002, methods. Multivariate calibration models were built using partial least squares (PLS) for the measurands studied. The developed models were validated using cross-validation and external validation; several statistical parameters were obtained to determine the robustness of the calibration models: (PCs) optimum number of components principal, (SECV) standard error of cross-validation, (R 2 cal) coefficient of determination of cross-validation, (SEP) standard error of validation, and (R 2 val) coefficient of determination for external validation and coefficient of variation (CV). The prediction accuracy for pH, redox potential, electrical conductivity, moisture, TSS, and ash was good, while for free acidity and HMF it was poor. The results demonstrate that attenuated total reflectance-Fourier transform infrared spectrometry is a valuable, rapid, and nondestructive tool for the quantification of physicochemical properties of honey. PMID:28070445
ERIC Educational Resources Information Center
Furman, Rich; Coyne, Ann; Negi, Nalini Junko
2008-01-01
This descriptive article explores the uses of poetry and journaling exercises as means of helping students develop their self-reflective capacities within the context of international social work. First, self-reflection and its importance to social work practice and education is discussed. Second, the importance of self-reflection in international…
Leaf Surface Effects on Retrieving Chlorophyll Content from Hyperspectral Remote Sensing
NASA Astrophysics Data System (ADS)
Qiu, Feng; Chen, JingMing; Ju, Weimin; Wang, Jun; Zhang, Qian
2017-04-01
Light reflected directly from the leaf surface without entering the surface layer is not influenced by leaf internal biochemical content. Leaf surface reflectance varies from leaf to leaf due to differences in the surface roughness features and is relatively more important in strong absorption spectral regions. Therefore it introduces dispersion of data points in the relationship between biochemical concentration and reflectance (especially in the visible region). Separation of surface from total leaf reflection is important to improve the link between leaf pigments content and remote sensing data. This study aims to estimate leaf surface reflectance from hyperspectral remote sensing data and retrieve chlorophyll content by inverting a modified PROSPECT model. Considering leaf surface reflectance is almost the same in the visible and near infrared spectral regions, a surface layer with a reflectance independent of wavelength but varying from leaf to leaf was added to the PROSPECT model. The specific absorption coefficients of pigments were recalibrated. Then the modified model was inverted on independent datasets to check the performance of the model in predicting the chlorophyll content. Results show that differences in estimated surface layer reflectance of various species are noticeable. Surface reflectance of leaves with epicuticular waxes and trichomes is usually higher than other samples. Reconstruction of leaf reflectance and transmittance in the 400-1000 nm wavelength region using the modified PROSPECT model is excellent with low root mean square error (RMSE) and bias. Improvements for samples with high surface reflectance (e.g. maize) are significant, especially for high pigment leaves. Moreover, chlorophyll retrieved from inversion of the modified model is consequently improved (RMSE from 5.9-13.3 ug/cm2 with mean value 8.1 ug/cm2, while mean correlation coefficient is 0.90) compared to results of PROSPECT-5 (RMSE from 9.6-20.2 ug/cm2 with mean value 13.1 ug/cm2, while mean correlation coefficient is 0.81). Underestimation of high chlorophyll content, which is due to underestimation of reflectance in the visible region of PROSPECT, is partially corrected or alleviated. Improvements are particularly noticeable for leaves with high surface reflectance or high chlorophyll content, which both lead to large proportions of surface reflectance to the total leaf reflectance.
Total reflection infrared spectroscopy of water-ice and frozen aqueous NaCl solutions.
Walker, Rachel L; Searles, Keith; Willard, Jesse A; Michelsen, Rebecca R H
2013-12-28
Liquid-like and liquid water at and near the surface of water-ice and frozen aqueous sodium chloride films were observed using attenuated total reflection infrared spectroscopy (ATR-IR). The concentration of NaCl ranged from 0.0001 to 0.01 M and the temperature varied from the melting point of water down to 256 K. The amount of liquid brine at the interface of the frozen films with the germanium ATR crystal increased with salt concentration and temperature. Experimental spectra are compared to reflection spectra calculated for a simplified morphology of a uniform liquid layer between the germanium crystal and the frozen film. This morphology allows for the amount of liquid observed in an experimental spectrum to be converted to the thickness of a homogenous layer with an equivalent amount of liquid. These equivalent thickness ranges from a nanometer for water-ice at 260 K to 170 nm for 0.01 M NaCl close to the melting point. The amounts of brine observed are over an order of magnitude less than the total liquid predicted by equilibrium thermodynamic models, implying that the vast majority of the liquid fraction of frozen solutions may be found in internal inclusions, grain boundaries, and the like. Thus, the amount of liquid and the solutes dissolved in them that are available to react with atmospheric gases on the surfaces of snow and ice are not well described by thermodynamic equilibrium models which assume the liquid phase is located entirely at the surface.
Reshaping Light-Emitting Diodes To Increase External Efficiency
NASA Technical Reports Server (NTRS)
Rogowski, Robert; Egalon, Claudio
1995-01-01
Light-emitting diodes (LEDs) reshaped, according to proposal, increasing amount of light emitted by decreasing fraction of light trapped via total internal reflection. Results in greater luminous output power for same electrical input power; greater external efficiency. Furthermore, light emitted by reshaped LEDs more nearly collimated (less diffuse). Concept potentially advantageous for conventional red-emitting LEDs. More advantageous for new "blue" LEDs, because luminous outputs and efficiencies of these devices very low. Another advantage, proposed conical shapes achieved relatively easily by chemical etching of semiconductor surfaces.
NASA Astrophysics Data System (ADS)
Wilson, T.; Kasper, E.; Oehme, M.; Schulze, J.; Korolev, K.
2014-11-01
We report on the direct excitation of 246 GHz longitudinal acoustic phonons in silicon doping superlattices by the resonant absorption of nanosecond-pulsed far-infrared laser radiation of the same frequency. A longitudinally polarized evanescent laser light field is coupled to the superlattice through a germanium prism providing total internal reflection at the superlattice interface. The ballistic phonon signal is detected by a superconducting aluminum bolometer. The sample is immersed in low-temperature liquid helium.
Spectral Analysis of the Shuttle Glow. AIS Science Support
1992-06-23
Prism (Total Internal Cylindrical Mirror Lens Reflection) Cylindrical Folding \\ Lens Plane Mirror -Cylindrical Slt Slit Mirror Fig. 7. Cron section...on Zerodur blanks, which width of the FOV to 0.14’ outward from the lens. have a coefficient of thermal expansion near zero. The width of the grating...oummambne toathe window of the iMag hunte~air. 3002. APPLIED OPTICS I VOL 3 .No, 16 / I June I02 68 Vacondry Minrror Prmr Mirror -luterence rlZters cm
2015-09-30
cell temperature is shown in Fig. 4. Here we begin with the premise when both In and Ga are incident on the wafer, the Sb consumption rate should be a...monitor the Sb consumption rate while slowly raising the cell temperature . It is evident from the data that the correct rate of total Sb consumption ...rise the substrate temperature during DE phase of DETA technique owing to the heat reflectance effect , while the power supplied to a substrate heater
Winner, Taryn L; Lanzarotta, Adam; Sommer, André J
2016-06-01
An effective method for detecting and characterizing counterfeit finished dosage forms and packaging materials is described in this study. Using attenuated total internal reflection Fourier transform infrared spectroscopic imaging, suspect tablet coating and core formulations as well as multi-layered foil safety seals, bottle labels, and cigarette tear tapes were analyzed and compared directly with those of a stored authentic product. The approach was effective for obtaining molecular information from structures as small as 6 μm.
Prism fingerprint sensor that uses a holographic optical element
NASA Astrophysics Data System (ADS)
Bahuguna, R. D.; Corboline, Tom
1996-09-01
A prism fingerprint sensor is described that uses a holographic grating glued to a right-angled prism. A light source normally illuminates the hypotenuse side of the prism with the finger pressed against the grating. The ridges and valleys of the finger are sensed on the basis of the principle of total internal reflection. The grating is used essentially to correct the distortion usually present with prism sensors. The quality of the fingerprint is very good: the pores on the ridges can be seen.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bobbitt, Jonathan M; Weibel, Stephen C; Elshobaki, Moneim
2014-12-16
Fourier transform (FT)-plasmon waveguide resonance (PWR) spectroscopy measures light reflectivity at a waveguide interface as the incident frequency and angle are scanned. Under conditions of total internal reflection, the reflected light intensity is attenuated when the incident frequency and angle satisfy conditions for exciting surface plasmon modes in the metal as well as guided modes within the waveguide. Expanding upon the concept of two-frequency surface plasmon resonance developed by Peterlinz and Georgiadis [ Opt. Commun. 1996, 130, 260], the apparent index of refraction and the thickness of a waveguide can be measured precisely and simultaneously by FT-PWR with an averagemore » percent relative error of 0.4%. Measuring reflectivity for a range of frequencies extends the analysis to a wide variety of sample compositions and thicknesses since frequencies with the maximum attenuation can be selected to optimize the analysis. Additionally, the ability to measure reflectivity curves with both p- and s-polarized light provides anisotropic indices of refraction. FT-PWR is demonstrated using polystyrene waveguides of varying thickness, and the validity of FT-PWR measurements are verified by comparing the results to data from profilometry and atomic force microscopy (AFM).« less
Bobbitt, Jonathan M; Weibel, Stephen C; Elshobaki, Moneim; Chaudhary, Sumit; Smith, Emily A
2014-12-16
Fourier transform (FT)-plasmon waveguide resonance (PWR) spectroscopy measures light reflectivity at a waveguide interface as the incident frequency and angle are scanned. Under conditions of total internal reflection, the reflected light intensity is attenuated when the incident frequency and angle satisfy conditions for exciting surface plasmon modes in the metal as well as guided modes within the waveguide. Expanding upon the concept of two-frequency surface plasmon resonance developed by Peterlinz and Georgiadis [Opt. Commun. 1996, 130, 260], the apparent index of refraction and the thickness of a waveguide can be measured precisely and simultaneously by FT-PWR with an average percent relative error of 0.4%. Measuring reflectivity for a range of frequencies extends the analysis to a wide variety of sample compositions and thicknesses since frequencies with the maximum attenuation can be selected to optimize the analysis. Additionally, the ability to measure reflectivity curves with both p- and s-polarized light provides anisotropic indices of refraction. FT-PWR is demonstrated using polystyrene waveguides of varying thickness, and the validity of FT-PWR measurements are verified by comparing the results to data from profilometry and atomic force microscopy (AFM).
NASA Technical Reports Server (NTRS)
Schramm, Harry F.; Sullivan, Kenneth W.
1991-01-01
An evaluation of the NASA's Marshall Space Flight Center (MSFC) strategy to implement Total Quality Management (TQM) in the Advanced Solid Rocket Motor (ASRM) Project is presented. The evaluation of the implementation strategy reflected the Civil Service personnel perspective at the project level. The external and internal environments at MSFC were analyzed for their effects on the ASRM TQM strategy. Organizational forms, cultures, management systems, problem solving techniques, and training were assessed for their influence on the implementation strategy. The influence of ASRM's effort was assessed relative to its impact on mature projects as well as future projects at MSFC.
NASA Technical Reports Server (NTRS)
Lipert, Robert J.; Porter, Marc D.; Siperko, Lorraine M.; Gazda, Daniel B.; Rutz, Jeff A.; Schultz, John R.; Carrizales, Stephanie M.; McCoy, J. Torin
2009-01-01
An experimental drinking water monitoring kit for the measurement of iodine and silver(I) was recently delivered to the International Space Station (ISS). The kit is based on Colorimetric Solid Phase Extraction (CSPE) technology, which measures the change in diffuse reflectance of indicator disks following exposure to a water sample. To satisfy additional spacecraft water monitoring requirements, CSPE has now been extended to encompass the measurement of total I (iodine, iodide, and triiodide) through the introduction of an oxidizing agent, which converts iodide and triiodide to iodine, for measurement using the same indicator disks currently being tested on ISS. These disks detect iodine, but are insensitive to iodide and triiodide. We report here the operational considerations, design, and ground-based performance of the CSPE method for total I. The results demonstrate that CSPE technology is poised to meet NASA's total I monitoring requirements.
Harnessing Multiple Internal Reflections to Design Highly Absorptive Acoustic Metasurfaces
NASA Astrophysics Data System (ADS)
Shen, Chen; Cummer, Steven A.
2018-05-01
The rapid development of metasurfaces has enabled numerous intriguing applications with acoustically thin sheets. Here we report the theory and experimental realization of a nonresonant sound-absorbing strategy using metasurfaces by harnessing multiple internal reflections. We theoretically and numerically show that the higher-order diffraction of thin gradient-index metasurfaces is tied to multiple internal reflections inside the unit cells. Highly absorbing acoustic metasurfaces can be realized by enforcing multiple internal reflections together with a small amount of loss. A reflective gradient-index acoustic metasurface is designed based on the theory, and we further experimentally verify the performance using a three-dimensional printed prototype. Measurements show over 99% energy absorption at the peak frequency and a 95% energy absorption bandwidth of around 600 Hz. The proposed mechanism provides an alternative route for sound absorption without the necessity of high absorption of the individual unit cells.
Passively Q-switched side pumped monolithic ring laser
NASA Technical Reports Server (NTRS)
Li, Steven X. (Inventor)
2012-01-01
Disclosed herein are systems and methods for generating a side-pumped passively Q-switched non-planar ring oscillator. The method introduces a laser into a cavity of a crystal, the cavity having a round-trip path formed by a reflection at a dielectrically coated front surface, a first internal reflection at a first side surface of the crystal at a non-orthogonal angle with the front, a second internal reflection at a top surface of the crystal, and a third internal reflection at a second side surface of the crystal at a non-orthogonal angle with the front. The method side pumps the laser at the top or bottom surface with a side pump diode array beam and generates an output laser emanating at a location on the front surface. The design can include additional internal reflections to increase interaction with the side pump. Waste heat may be removed by mounting the crystal to a heatsink.
Seismic reflection imaging, accounting for primary and multiple reflections
NASA Astrophysics Data System (ADS)
Wapenaar, Kees; van der Neut, Joost; Thorbecke, Jan; Broggini, Filippo; Slob, Evert; Snieder, Roel
2015-04-01
Imaging of seismic reflection data is usually based on the assumption that the seismic response consists of primary reflections only. Multiple reflections, i.e. waves that have reflected more than once, are treated as primaries and are imaged at wrong positions. There are two classes of multiple reflections, which we will call surface-related multiples and internal multiples. Surface-related multiples are those multiples that contain at least one reflection at the earth's surface, whereas internal multiples consist of waves that have reflected only at subsurface interfaces. Surface-related multiples are the strongest, but also relatively easy to deal with because the reflecting boundary (the earth's surface) is known. Internal multiples constitute a much more difficult problem for seismic imaging, because the positions and properties of the reflecting interfaces are not known. We are developing reflection imaging methodology which deals with internal multiples. Starting with the Marchenko equation for 1D inverse scattering problems, we derived 3D Marchenko-type equations, which relate reflection data at the surface to Green's functions between virtual sources anywhere in the subsurface and receivers at the surface. Based on these equations, we derived an iterative scheme by which these Green's functions can be retrieved from the reflection data at the surface. This iterative scheme requires an estimate of the direct wave of the Green's functions in a background medium. Note that this is precisely the same information that is also required by standard reflection imaging schemes. However, unlike in standard imaging, our iterative Marchenko scheme retrieves the multiple reflections of the Green's functions from the reflection data at the surface. For this, no knowledge of the positions and properties of the reflecting interfaces is required. Once the full Green's functions are retrieved, reflection imaging can be carried out by which the primaries and multiples are mapped to their correct positions, with correct reflection amplitudes. In the presentation we will illustrate this new methodology with numerical examples and discuss its potential and limitations.
Papagiannis, Georgios I; Roumpelakis, Ilias M; Triantafyllou, Athanasios I; Makris, Ioannis N; Babis, George C
2016-08-01
Total knee arthroplasties (TKAs) using well-designed, fixed bearing prostheses, such as medial pivot (MP), have produced good long-term results. Rotating-platform, posterior-stabilized (RP-PS) mobile bearing implants were designed to decrease polyethylene wear. Sagittal and coronal plane TKA biomechanics are well examined and correlated to polyethylene wear. However, limited research findings describe this relationship in transverse plane. We assumed that although axial plane biomechanics might not be the most destructive parameters on polyethylene wear, it is important to clarify their role because both joint kinematics and kinetics in all 3 planes are important input parameters for TKA wear testing (International Organization for Standardization 14243-1 and 14343-3). Our hypothesis was that transverse plane overall range of motion (ROM) and/or peak moment show differences that reflect on wear advantages when compared RP-PS implants to MP designs. Two groups (MPs = 24 and RP-PSs = 22 subjects) were examined by using 3D gait analysis. The variables were total internal-external rotation (IER) ROM and peak IER moments. No statistically significant difference was demonstrated between the 2 groups in kinetics (P = .389) or kinematics (P = .275). In the present study, no wear advantages were found between 2 TKAs. Both designs showed identical kinetics at the transverse plane in level-ground walking. Kinematic analysis could not illustrate any statistically significant difference in terms of overall IER ROM. Nevertheless, kinematic gait pattern differences observed possibly reflect different patterns of joint surface motion or abnormal gait patterns. Thus, wear testing with various input waveforms combined with functional data analysis will be necessary to identify the actual effects of gait variability on polyethylene wear. Copyright © 2016 Elsevier Inc. All rights reserved.
New mounting improves solar-cell efficiency
NASA Technical Reports Server (NTRS)
Shepard, N. F., Jr.
1980-01-01
Method boosts output by about 20 percent by trapping and redirecting solar radiation without increasing module depth. Mounted solar-cell array is covered with internally reflecting plate. Plate is attached to each cell by transparent adhesive, and space between cells is covered with layer of diffusely reflecting material. Solar energy falling on space between cells is diffused and reflected internally by plate until it is reflected onto solar cell.
Wittich, Christopher M; Reed, Darcy A; Ting, Henry H; Berger, Richard A; Nowicki, Kelly M; Blachman, Morris J; Mandrekar, Jayawant N; Beckman, Thomas J
2014-10-01
To validate a measure of reflection on participation in quality improvement (QI) activities and to identify associations with characteristics of QI projects, participants, and teams. This was a prospective validation study of all Mayo Clinic team participants who submitted QI projects for maintenance of certification (MOC) credit from 2010 to 2012. The authors developed a measure of reflection on participation in QI activities and explored associations between participants' overall reflection scores and characteristics of projects, participants, and teams. A total of 922 participants (567 physicians) on 118 teams completed QI projects and reflections. Factor analysis revealed a two-dimensional model with good internal consistency reliabilities (Cronbach alpha) for high (0.85) and low (0.81) reflection. Reflection scores (mean [standard deviation]) were associated with projects that changed practice (yes: 4.30 [0.51]; no: 3.71 [0.57]; P < .0001), changed the health care system (yes: 4.25 [0.54]; no: 4.03 [0.62]; P < .0001), and impacted patient safety (P < .0001). Physicians' reflection scores (4.27 [0.57]) were higher than support staff scores (4.07 [0.55]; P = .0005). A positive association existed between reflection scores and the number of QI roles per participant (P < .0001). There were no associations with participant gender, team size, or team diversity. The authors identified associations between participant reflection and the impact of QI projects, participants' professional roles, and participants' involvement with projects. With further study, the authors anticipate that the new measure of reflection will be useful for determining meaningful engagement in MOC.
Detection of creatinine enriched on a surface imprinted polystyrene film using FT-ATR-IR.
Sreenivasan, K
2006-01-01
The surface of polystyrene (PS) was chemically modified by coating a thin layer of polyaniline (PANI) by oxidizing aniline using ammonium persulfate. Affinity sites for creatinine, a clinically relevant molecule, were created in the coated layer by adding creatinine as print molecules during the oxidation. The imprinted layer adsorbed creatinine was compared to non-imprinted surface reflecting the creation of creatinine-specific sites on the surface. The equilibrium was attained rapidly, indicating that a material of this kind is suitable for sensing applications. The adsorbed creatinine on the surface was detected using the technique of Fourier transform attenuated total internal reflection infra red spectroscopy (FT-ATR-IR). The results show that molecularly imprinted surface can enrich molecules of interest and the enriched molecules can be detected using FT-IR.
Excitation of surface electromagnetic waves in a graphene-based Bragg grating
Sreekanth, Kandammathe Valiyaveedu; Zeng, Shuwen; Shang, Jingzhi; Yong, Ken-Tye; Yu, Ting
2012-01-01
Here, we report the fabrication of a graphene-based Bragg grating (one-dimensional photonic crystal) and experimentally demonstrate the excitation of surface electromagnetic waves in the periodic structure using prism coupling technique. Surface electromagnetic waves are non-radiative electromagnetic modes that appear on the surface of semi-infinite 1D photonic crystal. In order to fabricate the graphene-based Bragg grating, alternating layers of high (graphene) and low (PMMA) refractive index materials have been used. The reflectivity plot shows a deepest, narrow dip after total internal reflection angle corresponds to the surface electromagnetic mode propagating at the Bragg grating/air boundary. The proposed graphene based Bragg grating can find a variety of potential surface electromagnetic wave applications such as sensors, fluorescence emission enhancement, modulators, etc. PMID:23071901
Observation of the Goos-Hänchen shift with neutrons.
de Haan, Victor-O; Plomp, Jeroen; Rekveldt, Theo M; Kraan, Wicher H; van Well, Ad A; Dalgliesh, Robert M; Langridge, Sean
2010-01-08
The Goos-Hänchen effect is a spatial shift along an interface resulting from an interference effect that occurs for total internal reflection. This phenomenon was suggested by Sir Isaac Newton, but it was not until 1947 that the effect was experimentally observed by Goos and Hänchen. We provide the first direct, absolute, experimental determination of the Goos-Hänchen shift for a particle experiencing a potential well as required by quantum mechanics: namely, wave-particle duality. Here, the particle is a spin-polarized neutron reflecting from a film of magnetized material. We detect the effect through a subtle change in polarization of the neutron. Here, we demonstrate, through experiment and theory, that neutrons do exhibit the Goos-Hänchen effect and postulate that the associated time shift should also be observable.
Excitation of surface electromagnetic waves in a graphene-based Bragg grating.
Sreekanth, Kandammathe Valiyaveedu; Zeng, Shuwen; Shang, Jingzhi; Yong, Ken-Tye; Yu, Ting
2012-01-01
Here, we report the fabrication of a graphene-based Bragg grating (one-dimensional photonic crystal) and experimentally demonstrate the excitation of surface electromagnetic waves in the periodic structure using prism coupling technique. Surface electromagnetic waves are non-radiative electromagnetic modes that appear on the surface of semi-infinite 1D photonic crystal. In order to fabricate the graphene-based Bragg grating, alternating layers of high (graphene) and low (PMMA) refractive index materials have been used. The reflectivity plot shows a deepest, narrow dip after total internal reflection angle corresponds to the surface electromagnetic mode propagating at the Bragg grating/air boundary. The proposed graphene based Bragg grating can find a variety of potential surface electromagnetic wave applications such as sensors, fluorescence emission enhancement, modulators, etc.
Georgopoulos, Michael; Zehetmayer, Martin; Ruhswurm, Irene; Toma-Bstaendig, Sabine; Ségur-Eltz, Nikolaus; Sacu, Stefan; Menapace, Rupert
2003-01-01
This study assesses differences in relative tumour regression and internal acoustic reflectivity after 3 methods of radiotherapy for uveal melanoma: (1) brachytherapy with ruthenium-106 radioactive plaques (RU), (2) fractionated high-dose gamma knife stereotactic irradiation in 2-3 fractions (GK) or (3) fractionated linear-accelerator-based stereotactic teletherapy in 5 fractions (Linac). Ultrasound measurements of tumour thickness and internal reflectivity were performed with standardised A scan pre-operatively and 3, 6, 9, 12, 18, 24 and 36 months postoperatively. Of 211 patients included in the study, 111 had a complete 3-year follow-up (RU: 41, GK: 37, Linac: 33). Differences in tumour thickness and internal reflectivity were assessed with analysis of variance, and post hoc multiple comparisons were calculated with Tukey's honestly significant difference test. Local tumour control was excellent with all 3 methods (>93%). At 36 months, relative tumour height reduction was 69, 50 and 30% after RU, GK and Linac, respectively. In all 3 treatment groups, internal reflectivity increased from about 30% initially to 60-70% 3 years after treatment. Brachytherapy with ruthenium-106 plaques results in a faster tumour regression as compared to teletherapy with gamma knife or Linac. Internal reflectivity increases comparably in all 3 groups. Besides tumour growth arrest, increasing internal reflectivity is considered as an important factor indicating successful treatment. Copyright 2003 S. Karger AG, Basel
Montoro, Alegría; Sebastià, Natividad; Candela-Juan, Cristian; Barquinero, Joan Francesc; Soriano, José Miguel; Almonacid, Miguel; Alonso, Oscar; Guasp, Miguel; Marques-Sule, Elena; Cervera, José; Such, Esperanza; Arnal, Clara; Villaescusa, Juan Ignacio
2013-11-01
To survey the possible presence of chromosomal damage and internal contamination in a group of Ukrainian children and adolescents, 20 years after the Chernobyl accident at the Nuclear Power Plant. Cytogenetical procedures were performed according to dicentric assay in 55 Ukrainian children and adolescents (29 boys and 26 girls), living near Chernobyl. In addition, a whole body detector and urinalysis were used to detect internal contamination. 36 dicentrics were found in a total of 53,477 metaphases scored in these children, which reflected a frequency of dicentrics below the background level. On the other hand, internal contamination was not detected in any subject studied. Since the estimated absorbed dose is below the detection limit, according to both biological and physical dosimetry, radiation overexposure during the last 3-5 years has not been detected in the considered subjects.
Application to Noninvasive Measurement of Blood Components Based on Infrared Spectroscopy
NASA Astrophysics Data System (ADS)
Tamura, Kazuto; Ishizawa, Hiroaki; Fujita, Keiichi; Kaneko, Wataru; Morikawa, Tomotaka; Toba, Eiji; Kobayashi, Hideo
Recently, lifestyle diseases (diabetics, hyperlipemia etc.) have been steadily increasing, because change of diet, lack of exercise, increase an alcoholic intake, and increase a stress. It is a matter of vital importance to us. About tens of millions of people in Japan have approached the danger of lifestyle diseases. So they have to do a blood test to make sure that they have controlled physical condition themselves. Therefore, they have to measure blood components again and again. So, they are burden too heavy. This paper describes a new noninvasive measurement of blood components based on optical sensing. This uses Fourier transform infrared spectroscopy of attenuated total reflection. In order to study, the influence of individual difference, the internal standard method was introduced. This paper describes the detail of the internal standard method and its effect to the blood components calibration. Significant improvement was obtained by using the internal standard.
Character of the opposition effect and negative polarization
NASA Technical Reports Server (NTRS)
Pieters, Carle M.; Shkuratov, Yu. G.; Stankevich, D. G.
1991-01-01
Photometric and polarimetric properties at small phase angles were measured for silicates with controlled surface properties in order to distinguish properties that are associated with surface reflection from those that are associated with multiple scattering from internal grain boundaries. These data provide insight into the causes and conditions of photometric properties observed at small phase angles for dark bodies of the solar system. Obsidian was chosen to represent a silicate dielectric with no internal scattering boundaries. Because obsidian is free of internal scatterers, light reflected from both the rough and smooth obsidian samples is almost entirely single and multiple Fresnel reflections form surface facets with no body component. Surface structure alone cannot produce an opposition effect. Comparison of the obsidian and basalt results indicates that for an opposition effect to occur, surface texture must be both rough and contain internal scattering interfaces. Although the negative polarization observed for the obsidian samples indicates single and multiple reflections are part of negative polarization, the longer inversion angle of the multigrain inversion samples implies that internal reflections must also contribute a significant negative polarization component.
Germania Quo Vadis?: Dynamics of Change in German Security Policy
2007-06-01
Keohane, Robert O., Michael Brecher and Frank Harveys, eds. Institutional Theory in international Relations. In: Millennial Reflections on International...Hegemony: Cooperation and Discord in the World Political Economy, (Princeton University Press, 1984), pp. 78-109; Robert O. Keohane, “ Institutional ... Theory in international Relations,” in Michael Brecher and Frank Harveys, eds., Millennial Reflections on International Studies (University of Michigan
Joyce-McCoach, Joanne T; Parrish, Dominique R; Andersen, Patrea R; Wall, Natalie
2013-09-01
Being reflective is well established as an important conduit of practice development, a desirable tertiary graduate quality and a core competency of health professional membership. By assisting students to be more effective in their ability to reflect, they are better able to formulate strategies to manage issues experienced within a professional context, which ultimately assists them to be better service providers. However, some students are challenged by the practice of reflection and these challenges are even more notable for international students. This paper presents a teaching initiative that focused specifically on enhancing the capacity of an international cohort of nursing students, to engage in reflective practice. The initiative centered on an evaluation of a reflective practice core subject, which was taught in a Master of Nursing programme delivered in Hong Kong. A learning-centered framework was used to evaluate the subject and identify innovative strategies that would better assist international students to develop reflective practices. The outcomes of curriculum and teaching analysis and proposed changes and innovations in teaching practice to support international students are presented and discussed. Copyright © 2012 Elsevier Ltd. All rights reserved.
Sastre Toraño, J; van Hattum, S H
2001-10-01
A new method is presented for the quantitative analysis of compounds in pharmaceutical preparations Fourier transform (FT) mid-infrared (MIR) spectroscopy with an attenuated total reflection (ATR) module. Reduction of the quantity of overlapping absorption bands, by interaction of the compound of interest with an appropriate solvent, and the employment of an internal standard (IS), makes MIR suitable for quantitative analysis. Vigabatrin, as active compound in vigabatrin 100-mg capsules, was used as a model compound for the development of the method. Vigabatrin was extracted from the capsule content with water after addition of a sodium thiosulfate IS solution. The extract was concentrated by volume reduction and applied to the FTMIR-ATR module. Concentrations of unknown samples were calculated from the ratio of the vigabatrin band area (1321-1610 cm(-1)) and the IS band area (883-1215 cm(-1)) using a calibration standard. The ratio of the area of the vigabatrin peak to that of the IS was linear with the concentration in the range of interest (90-110 mg, in twofold; n=2). The accuracy of the method in this range was 99.7-100.5% (n=5) with a variability of 0.4-1.3% (n=5). The comparison of the presented method with an HPLC assay showed similar results; the analysis of five vigabatrin 100-mg capsules resulted in a mean concentration of 102 mg with a variation of 2% with both methods.
Effect of Ram and Zenith Exposure on the Optical Properties of Polymers in Space
NASA Technical Reports Server (NTRS)
Li, Yuachun; de Groh, Kim K.; Banks, Bruce A.; Leneghan, Halle; Asmar, Olivia
2017-01-01
The temperature of spacecraft is influenced by the solar absorptance and thermal emittance of the external spacecraft materials. Optical and thermal properties can degrade over time in the harsh low Earth orbital (LEO) space environment where spacecraft external materials are exposed to various forms of radiation, thermal cycling, and atomic oxygen. Therefore, it is important to test the durability of spacecraft materials in the space environment. One objective of the Polymers and Zenith Polymers Experiments was to determine the effect of LEO space exposure on the optical properties of various spacecraft polymers. These experiments were flown as part of the Materials International Space Station Experiment 7 (MISSE 7) mission on the exterior of the International Space Station (ISS) for 1.5 years. Samples were flown in ram, wake or zenith directions, receiving varying amounts of atomic oxygen and solar radiation exposure. Total and diffuse reflectance and transmittance of flight and corresponding control samples were obtained post-flight using a Cary 5000 UV-Vis-NIR Spectrophotometer. Integrated air mass zero solar absorptance (s) of the flight and control samples were computed from the total transmittance and reflectance, and compared. The optical data are compared with similar polymers exposed to space for four years as part of MISSE 2, and with atomic oxygen erosion data, to help understand the degradation of these polymers in the space environment. Results show that prolonged space exposure increases the solar absorptance of some materials. Knowing which polymers remain stable will benefit future spacecraft design.
NASA Astrophysics Data System (ADS)
Schmitz, R.; Yordanov, S.; Butt, H. J.; Koynov, K.; Dünweg, B.
2011-12-01
Total internal reflection fluorescence cross-correlation spectroscopy (TIR-FCCS) has recently [S. Yordanov , Optics ExpressOPEXFF1094-408710.1364/OE.17.021149 17, 21149 (2009)] been established as an experimental method to probe hydrodynamic flows near surfaces, on length scales of tens of nanometers. Its main advantage is that fluorescence occurs only for tracer particles close to the surface, thus resulting in high sensitivity. However, the measured correlation functions provide only rather indirect information about the flow parameters of interest, such as the shear rate and the slip length. In the present paper, we show how to combine detailed and fairly realistic theoretical modeling of the phenomena by Brownian dynamics simulations with accurate measurements of the correlation functions, in order to establish a quantitative method to retrieve the flow properties from the experiments. First, Brownian dynamics is used to sample highly accurate correlation functions for a fixed set of model parameters. Second, these parameters are varied systematically by means of an importance-sampling Monte Carlo procedure in order to fit the experiments. This provides the optimum parameter values together with their statistical error bars. The approach is well suited for massively parallel computers, which allows us to do the data analysis within moderate computing times. The method is applied to flow near a hydrophilic surface, where the slip length is observed to be smaller than 10nm, and, within the limitations of the experiments and the model, indistinguishable from zero.
Drugs of abuse detection in saliva based on actuated optical method
NASA Astrophysics Data System (ADS)
Shao, Jie; Li, Zhenyu; Jiang, Hong; Wang, Wenlong; Wu, Yixuan
2014-12-01
There has been a considerable increase in the abuse of drugs during the past decade. Combing drug use with driving is very dangerous. More than 11% of drivers in a roadside survey tested positive for drugs, while 18% of drivers killed in accidents tested positive for drugs as reported in USA, 2007. Toward developing a rapid drug screening device, we use saliva as the sample, and combining the traditional immunoassays method with optical magnetic technology. There were several methods for magnetic nanoparticles detection, such as magnetic coils, SQUID, microscopic imaging, and Hall sensors. All of these methods were not suitable for our demands. By developing a novel optical scheme, we demonstrate high-sensitivity detection in saliva. Drugs of abuse are detected at sub-nano gram per milliliter levels in less than 120 seconds. Evanescent wave principle has been applied to sensitively monitor the presence of magnetic nanoparticles on the binding surface. Like the total internal reflection fluorescence microscope (TIRFM), evanescent optical field is generated at the plastic/fluid interface, which decays exponentially and penetrates into the fluid by only a sub-wavelength distance. By disturbance total internal reflection with magnetic nanoparticles, the optical intensity would be influenced. We then detected optical output by imaging the sensor surface onto a CCD camera. We tested four drugs tetrahydrocannabinol (THC), methamphetamine (MAMP), ketamine (KET), morphine (OPI), using this technology. 100 ng mL-1 sensitivity was achieved, and obvious evidence showed that this results could be improved in further researches.
Teng, Tun-Chien; Lai, Wei-Che
2014-12-15
This study proposed a planar solar concentrator featuring alignment-free total-internal-reflection (TIR) collectors and an innovative compound tracker. The compound tracker, combining a mechanical single-axis tracker and scrollable prism sheets, can achieve a performance on a par with dual-axis tracking while reducing the cost of the tracking system and increasing its robustness. The alignment-free TIR collectors are assembled on the waveguide without requiring alignment, so the planar concentrator is relatively easily manufactured and markedly increases the feasibility for use in large concentrators. Further, the identical TIR collector is applicable to various-sized waveguide slab without requiring modification, which facilitates flexibility regarding the size of the waveguide slab. In the simulation model, the thickness of the slab was 2 mm, and its maximal length reached 6 m. With an average angular tolerance of ±0.6°, and after considering both the Fresnel loss and the angular spread of the sun, the simulation indicates that the waveguide concentrator of a 1000-mm length provides the optical efficiencies of 62-77% at the irradiance concentrations of 387-688, and the one of a 2000-mm length provides the optical efficiencies of 52-64.5% at the irradiance concentrations of 645-1148. Alternatively, if a 100-mm horizontally staggered waveguide slab is collocated with the alignment-free TIR collectors, the optical efficiency would be greatly improved up to 91.5% at an irradiance concentration of 1098 (C(geo) = 1200X).
Accessible biometrics: A frustrated total internal reflection approach to imaging fingerprints.
Smith, Nathan D; Sharp, James S
2017-05-01
Fingerprints are widely used as a means of identifying persons of interest because of the highly individual nature of the spatial distribution and types of features (or minuta) found on the surface of a finger. This individuality has led to their wide application in the comparison of fingerprints found at crime scenes with those taken from known offenders and suspects in custody. However, despite recent advances in machine vision technology and image processing techniques, fingerprint evidence is still widely being collected using outdated practices involving ink and paper - a process that can be both time consuming and expensive. Reduction of forensic service budgets increasingly requires that evidence be gathered and processed more rapidly and efficiently. However, many of the existing digital fingerprint acquisition devices have proven too expensive to roll out on a large scale. As a result new, low-cost imaging technologies are required to increase the quality and throughput of the processing of fingerprint evidence. Here we describe an inexpensive approach to digital fingerprint acquisition that is based upon frustrated total internal reflection imaging. The quality and resolution of the images produced are shown to be as good as those currently acquired using ink and paper based methods. The same imaging technique is also shown to be capable of imaging powdered fingerprints that have been lifted from a crime scene using adhesive tape or gel lifters. Copyright © 2017 The Chartered Society of Forensic Sciences. Published by Elsevier B.V. All rights reserved.
Solid-state laser pumping with a planar compound parabolic concentrator.
Panteli, D V; Pani, B M; Beli, L Z
1997-10-20
A novel solid-state laser-pumping scheme is proposed that combines a reflective lamp chamber and a compound parabolic concentrator (CPC) as a light guide. The CPC is made of a transparent material of high refractive index, and light is guided by the total internal reflection, with drastically reduced reflection losses. Material is chosen so that the absorption losses are minimized in the pumping wavelength range. The lamp chamber is designed with the principles of nonimaging optics, which ensures that the radiation is efficiently transferred from the lamp to the input aperture of the CPC. The pumping efficiency was first estimated theoretically, which gave us enough justification for the more accurate calculations with ray tracing. Single as well as multiple pumping cavities are discussed. New pumping geometry results in significantly increased pumping efficiency compared with conventional geometries. Also the lamp and the laser rod are separated, leading to reduced thermal load. We found that the proposed pumping method is also applicable to diode-pumped lasers.
Electromagnetic wave propagation through a dielectric-chiral interface and through a chiral slab
NASA Technical Reports Server (NTRS)
Bassiri, S.; Papas, C. H.; Engheta, N.
1988-01-01
The reflection from and transmission through a semiinfinite chiral medium are analyzed by obtaining the Fresnel equations in terms of parallel- and perpendicular-polarized modes, and a comparison is made with results reported previously. The chiral medium is described electromagnetically by the constitutive relations D = (epsilon)E+i(gamma)B and H = i(gamma)E+(1/mu)B. The constants epsilon, mu and gamma are real and have values that are fixed by the size, the shape, and the spatial distribution of the elements that collectively compose the medium. The conditions are obtained for the total internal reflection of the incident wave from the interface and for the existence of the Brewster angle. The effects of the chirality on the polarization and the intensity of the reflected wave from the chiral half-space are discussed and illustrated by using the Stokes parameters. The propagation of electromagnetic wave through an infinite slab of chiral medium is formulated for oblique incidence and solved analytically for the case of normal incidence.
Axelrod, Daniel
2012-08-01
Microscopic fluorescent samples of interest to cell and molecular biology are commonly embedded in an aqueous medium near a solid surface that is coated with a thin film such as a lipid multilayer, collagen, acrylamide, or a cell wall. Both excitation and emission of fluorescent single molecules near film-coated surfaces are strongly affected by the proximity of the coated surface, the film thickness, its refractive index and the fluorophore's orientation. For total internal reflection excitation, multiple reflections in the film can lead to resonance peaks in the evanescent intensity versus incidence angle curve. For emission, multiple reflections arising from the fluorophore's near field emission can create a distinct intensity pattern in both the back focal plane and the image plane of a high aperture objective. This theoretical analysis discusses how these features can be used to report film thickness and refractive index, and fluorophore axial position and orientation. © 2012 The Author Journal of Microscopy © 2012 Royal Microscopical Society.
NASA Technical Reports Server (NTRS)
Ahuja, K. K.; Tanna, H. K.; Tester, B. J.
1981-01-01
When a free jet (or open jet) is used as a wind tunnel to simulate the effects of flight on model noise sources, it is necessary to calibrate out the effects of the free jet shear layer on the transmitted sound, since the shear layer is absent in the real flight case. In this paper, a theoretical calibration procedure for this purpose is first summarized; following this, the results of an experimental program, designed to test the validity of the various components of the calibration procedure, are described. The experiments are conducted by using a point sound source located at various axial positions within the free jet potential core. By using broadband excitation and cross-correlation methods, the angle changes associated with ray paths across the shear layer are first established. Measurements are then made simultaneously inside and outside the free jet along the proper ray paths to determine the amplitude changes across the shear layer. It is shown that both the angle and amplitude changes can be predicted accurately by theory. It is also found that internal reflection at the shear layer is significant only for large ray angles in the forward quadrant where total internal reflection occurs. Finally, the effects of sound absorption and scattering by the shear layer turbulence are also examined experimentally.
NASA Astrophysics Data System (ADS)
Zhang, Airui; Jin, Axiang; Wang, Hai; Wang, Xiaokang; Zha, Pengfei; Wang, Meiling; Song, Xiaoping; Gao, Sitian
2018-03-01
Quantitative determination of trace elements like S, Fe, Cu, Mn and Pb in gasoline and S in diesel is of great importance due to the growing concerns over air pollution, human health and engine failure caused by utilization of gasoline and diesel with these harmful elements. A method of total reflection X-ray fluorescence (TXRF) was developed to measure these harmful trace elements in gasoline and diesel. A variety of factors to affect measurement results, including TXRF parameters, microwave-assisted digestion conditions and internal standard element and its addition, were examined to optimize these experimental procedures. The hydrophobic treatment of the surface of quartz reflectors to support the analyte with neutral silicone solutions could prepare thin films of gasoline and diesel digestion solutions for subsequent TXRF analysis. The proposed method shows good potential and reliability to determine the content of harmful trace elements in gasoline and diesel with high sensitivity and accuracy without drawing different standard calibration curves, and can be easily employed to screen gasoline and diesel in routine quality control and assurance.
Measuring critical thinking in pre-registration midwifery students: A multi-method approach.
Carter, Amanda G; Creedy, Debra K; Sidebotham, Mary
2018-02-01
Test the concurrent validity of three newly developed tools (student self-rating, preceptor rating, and reflective writing) that aim to measure critical thinking in midwifery practice. A descriptive matched cohort design was used. Australian research intensive university offering a three year Bachelor of Midwifery programme. Fifty-five undergraduate midwifery students. Students assessed their ability to apply critical thinking in midwifery practice using a 25-item tool and a 5-item subscale in Motivated Strategies for Learning Questionnaire. Clinical preceptors completed a 24-item tool assessing the students' application of critical thinking in practice. Reflective writing by students was assessed by midwifery academics using a 15-item tool. Internal reliability, and concurrent validity were assessed. Correlations, t-tests, multiple regression and confidence levels were calculated for the three scales and associations with student characteristics. The three scales achieved good internal reliability with a Cronbach's alpha coefficient between 0.93 and 0.97. Matched total scores for the three critical thinking scales were moderately correlated; student/preceptor (r=0.36, p<0.01); student/reflective writing (r=0.38, p<0.01); preceptor/reflective writing (r=0.30, p<0.05). All critical thinking mean scores were higher for students with a previous degree, but only significant for reflective writing (t (53)=-2.35, p=0.023). Preceptor ratings were predictive of GPA (beta=0.50, p<0.001, CI=0.10 to 0.30). Students' self-rating scores were predictive of year level (beta=0.32, p<0.05, CI=0.00 to 0.03). The student, preceptor, and reflective writing tools were found to be reliable and valid measures of critical thinking. The three tools can be used individually or in combination to provide students with various sources of feedback to improve their practice. The tools allow formative measurement of critical thinking over time. Further testing of the tools with larger, diverse samples is recommended. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
Clinics in Orthopedic Surgery's Evolution into an International Journal Based on Journal Metrics.
Huh, Sun
2016-06-01
This article is aimed at providing evidence of increased international recognition of Clinics in Orthopedic Surgery (CiOS) based on journal metrics. Since 7 years have passed since its launch in 2009, it is time to reflect on the journal's efforts to be recognized as a top-notch journal. The following journal metrics were analyzed from the journal's homepage and Web of Science Core Collection database: number of citable and noncitable articles; number of original articles supported by grants; editorial board members' countries; authors' countries; citing authors' countries; source titles of citing articles; impact factor; total citations; comparison of impact factor with 3 Science Citation Index Expanded journals; and Hirsch index (H-index). Of the total 392 articles, 378 were citable articles (96.4%). Of the total 282 original articles, 52 (18.4%) were supported by research grants. The editorial board members were from 13 countries. Authors were from 20 countries. The number of countries of citing authors was 66. The number of source titles of citing articles was more than 100. The total citations of CiOS have increased from 0 in 2009 to 374 in 2015. The impact factors without self-citations of CiOS were the greatest among 4 Asian journals in 2013 and 2014. The 2015 impact factor was calculated as 0.79 in January 2016. The H-index was 13. CiOS can be considered to have reached the level of top-notch journal in the orthopedic field based on journal metrics. The inclusion of the journal in PubMed Central appears to have increased international relevance of the journal.
NASA Astrophysics Data System (ADS)
Aksu, Anil A.
2017-09-01
In this paper, we have considered the non-linear effects arising due to the collision of incident and reflected internal wave beams. It has already been shown analytically [Tabaei et al., "Nonlinear effects in reflecting and colliding internal wave beams," J. Fluid Mech. 526, 217-243 (2005)] and numerically [Rodenborn et al., "Harmonic generation by reflecting internal waves," Phys. Fluids 23, 026601 (2011)] that the internal wave beam collision generates the higher harmonics and mean flow in a linear stratification. In this paper, similar to previous analytical work, small amplitude wave theory is employed; however, it is formulated from energetics perspective which allows considering internal wave beams as the product of slowly varying amplitude and fast complex exponential. As a result, the mean energy propagation equation for the second harmonic wave is obtained. Finally, a similar dependence on the angle of incidence is obtained for the non-linear energy transfer to the second harmonic with previous analyses. A possible physical mechanism for this angle dependence on the second harmonic generation is also discussed here. In addition to previous studies, the viscous effects are also included in the mean energy propagation equation for the incident, the reflecting, and the second harmonic waves. Moreover, even though the mean flow obtained here is only confined to the interaction region, it is also affected by viscosity via the decay in the incident and the reflecting internal wave beams. Furthermore, a framework for the non-linear harmonic generation in non-linear stratification is also proposed here.
Improved power efficiency for very-high-temperature solar-thermal-cavity receivers
McDougal, A.R.; Hale, R.R.
1982-04-14
This invention is an improved solar energy cavity receiver for exposing materials and components to high temperatures. The receiver includes a housing having an internal reflective surface defining a cavity and having an inlet for admitting solar radiation thereto. A photothermal absorber is positiond in the cavity to receive radiation from the inlet. A reflective baffle is positioned between the absorber and the inlet to severely restrict the re-radiation of energy through the inlet. The front surface of the baffle defines a narrow annulus with the internal reflective surface of the housing. The front surface of the baffle is contoured to reflect incoming radiation onto the internal surface of the housing, from which it is reflected through the annulus and onto the front surface of the absorber. The back surface of the baffle intercepts radiation from the front of the absorber. With this arrangement, a high percentage of the solar power input is retained in the cavity; thus, high internal temperatues are attained.
Power efficiency for very high temperature solar thermal cavity receivers
McDougal, Allan R.; Hale, Robert R.
1984-01-01
This invention is an improved solar energy cavity receiver for exposing materials and components to high temperatures. The receiver includes a housing having an internal reflective surface defining a cavity and having an inlet for admitting solar radiation thereto. A photothermal absorber is positioned in the cavity to receive radiation from the inlet. A reflective baffle is positioned between the absorber and the inlet to severely restrict the re-radiation of energy through the inlet. The front surface of the baffle defines a narrow annulus with the internal reflective surface of the housing. The front surface of the baffle is contoured to reflect incoming radiation onto the internal surface of the housing, from which it is reflected through the annulus and onto the front surface of the absorber. The back surface of the baffle intercepts infrared radiation from the front of the absorber. With this arrangement, a high percentage of the solar power input is retained in the cavity; thus, high internal temperatures are attained.
Hedenrud, Tove M; Svensson, Staffan A; Wallerstedt, Susanna M
2013-08-12
Psychotropic drug prescribing is problematic and knowledge of factors affecting the initiation and maintenance of such prescribing is incomplete. Such knowledge could provide a basis for the design of interventions to change prescribing patterns for psychotropics. The aim of this study was to explore the views of general practitioners (GPs), GP interns, and heads of primary care units on factors affecting the prescribing of psychotropic drugs in primary care. We performed four focus group discussions in Gothenburg, Sweden, with a total of 21 participants (GPs, GP interns, and heads of primary care units). The focus group discussions were transcribed verbatim and analyzed using manifest content analysis. Three different themes emerged from the focus group discussions. The first theme Seeking care for symptoms, reflects the participants' understanding of why patients approach primary care and comprised categories such as knowledge, attitudes, and society and the media. The second theme, Lacking a framework, resources, and treatment alternatives, which reflects the conditions for the physician-patient interaction, comprised categories such as economy and resources, technology, and organizational aspects. The third theme, Restricting or maintaining prescriptions, with the subthemes Individual factors and External influences, reflects the physicians' internal decision making and comprised categories such as emotions, knowledge, and pharmaceutical industry. The results of the present study indicate that a variety of factors may affect the prescribing of psychotropic medications in primary care. Many factors were related to characteristics of the patient, the physician or their interaction, rather than the patients' medical needs per se. The results may be useful for interventions to improve psychotropic prescribing in primary care.
Total reflection infrared spectroscopy of water-ice and frozen aqueous NaCl solutions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, Rachel L.; Searles, Keith; Willard, Jesse A.
2013-12-28
Liquid-like and liquid water at and near the surface of water-ice and frozen aqueous sodium chloride films were observed using attenuated total reflection infrared spectroscopy (ATR-IR). The concentration of NaCl ranged from 0.0001 to 0.01 M and the temperature varied from the melting point of water down to 256 K. The amount of liquid brine at the interface of the frozen films with the germanium ATR crystal increased with salt concentration and temperature. Experimental spectra are compared to reflection spectra calculated for a simplified morphology of a uniform liquid layer between the germanium crystal and the frozen film. This morphologymore » allows for the amount of liquid observed in an experimental spectrum to be converted to the thickness of a homogenous layer with an equivalent amount of liquid. These equivalent thickness ranges from a nanometer for water-ice at 260 K to 170 nm for 0.01 M NaCl close to the melting point. The amounts of brine observed are over an order of magnitude less than the total liquid predicted by equilibrium thermodynamic models, implying that the vast majority of the liquid fraction of frozen solutions may be found in internal inclusions, grain boundaries, and the like. Thus, the amount of liquid and the solutes dissolved in them that are available to react with atmospheric gases on the surfaces of snow and ice are not well described by thermodynamic equilibrium models which assume the liquid phase is located entirely at the surface.« less
ERIC Educational Resources Information Center
Levine, Rachel B.; Kern, David E.; Wright, Scott M.
2008-01-01
Narrative writing has been used to promote reflection and increased self-awareness among physicians. The purpose of this study was to determine the impact of prompted narrative writing on reflection. Thirty-two interns at 9 internal medicine residency programs participated in a year-long qualitative study about personal growth beginning in July of…
International Mindedness through the Looking Glass: Reflections on a Concept
ERIC Educational Resources Information Center
Castro, Paloma; Lundgren, Ulla; Woodin, Jane
2015-01-01
The aim of this article is to report and reflect on a research project involving the conceptualization of the term "International Mindedness", which is used across a range of International Baccalaureate (IB) global and local contexts. The research process involved both a critical analysis of IB official documents and a literature review…
An Analysis Method for Superconducting Resonator Parameter Extraction with Complex Baseline Removal
NASA Technical Reports Server (NTRS)
Cataldo, Giuseppe
2014-01-01
A new semi-empirical model is proposed for extracting the quality (Q) factors of arrays of superconducting microwave kinetic inductance detectors (MKIDs). The determination of the total internal and coupling Q factors enables the computation of the loss in the superconducting transmission lines. The method used allows the simultaneous analysis of multiple interacting discrete resonators with the presence of a complex spectral baseline arising from reflections in the system. The baseline removal allows an unbiased estimate of the device response as measured in a cryogenic instrumentation setting.
Alahautala, Taito; Hernberg, Rolf
2004-02-01
Uniform illumination was generated by use of a large number of diode laser emitters and a single nonimaging paraboloid with a Lambertian scatterer in the truncation plane. Laser light traverses a path toward the Lambertian surface and back by total internal reflection. An overall efficiency of 69% was demonstrated. Improvements that would increase the efficiency to more than 85% are suggested. The illuminated area is circular, with 14-mm diameter. The spatial nonuniformity of the beam profile is less than +/- 2%.
Modulation analysis of nonlinear beam refraction at an interface in liquid crystals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Assanto, Gaetano; Smyth, Noel F.; Xia Wenjun
2011-09-15
A theoretical investigation of solitary wave refraction in nematic liquid crystals is undertaken. A modulation theory based on a Lagrangian formulation of the governing optical solitary wave equations is developed. The resulting low-dimensional equations are found to give solutions in excellent agreement with full numerical solutions of the governing equations, as well as with previous experimental studies. The analysis deals with a number of types of refraction from a more to a less optically dense medium, the most famous being the Goos-Haenchen shift upon total internal reflection.
Sanderson, Michael J; Smith, Ian; Parker, Ian; Bootman, Martin D
2014-10-01
Fluorescence microscopy is a major tool with which to monitor cell physiology. Although the concepts of fluorescence and its optical separation using filters remain similar, microscope design varies with the aim of increasing image contrast and spatial resolution. The basics of wide-field microscopy are outlined to emphasize the selection, advantages, and correct use of laser scanning confocal microscopy, two-photon microscopy, scanning disk confocal microscopy, total internal reflection, and super-resolution microscopy. In addition, the principles of how these microscopes form images are reviewed to appreciate their capabilities, limitations, and constraints for operation. © 2014 Cold Spring Harbor Laboratory Press.
2014-11-24
layere, which was a thin plate bonded to a solid block of fused quartz. The plate was also made of fused quartz so the entire “assembly” may be... thin plate and a block of fused quartz. Residues of the lacquer Quartz plate Metal strip Epoxy layer Block of quartz Fig. 2.4.4. Specimen...depth therefore it was made as a combination of two pieces of fused quartz, a block and a thin plate , and a foreign inclusion between them. The plate was
NASA Astrophysics Data System (ADS)
Lembessis, V. E.; Babiker, M.; Andrews, D. L.
2009-01-01
It is shown how the total internal reflection of orbital-angular-momentum-endowed light can lead to the generation of evanescent light possessing rotational properties in which the intensity distribution is firmly localized in the vicinity of the surface. The characteristics of these surface optical vortices depend on the form of the incident light and on the dielectric mismatch of the two media. The interference of surface optical vortices is shown to give rise to interesting phenomena, including pattern rotation akin to a surface optical Ferris wheel. Applications are envisaged to be in atom lithography, optical surface tweezers, and spanners.
Sanderson, Michael J.; Smith, Ian; Parker, Ian; Bootman, Martin D.
2016-01-01
Fluorescence microscopy is a major tool with which to monitor cell physiology. Although the concepts of fluorescence and its optical separation using filters remain similar, microscope design varies with the aim of increasing image contrast and spatial resolution. The basics of wide-field microscopy are outlined to emphasize the selection, advantages, and correct use of laser scanning confocal microscopy, two-photon microscopy, scanning disk confocal microscopy, total internal reflection, and super-resolution microscopy. In addition, the principles of how these microscopes form images are reviewed to appreciate their capabilities, limitations, and constraints for operation. PMID:25275114
Air gap resonant tunneling bandpass filter and polarizer.
Melnyk, A; Bitarafan, M H; Allen, T W; DeCorby, R G
2016-04-15
We describe a bandpass filter based on resonant tunneling through an air layer in the frustrated total internal reflection regime, and show that the concept of induced transmission can be applied to the design of thin film matching stacks. Experimental results are reported for Si/SiO2-based devices exhibiting a polarization-dependent passband, with bandwidth on the order of 10 nm in the 1550 nm wavelength range, peak transmittance on the order of 80%, and optical density greater than 5 over most of the near infrared region.
Insight, rumination, and self-reflection as predictors of well-being.
Harrington, Rick; Loffredo, Donald A
2011-01-01
Dispositional private self-focused attention variables such as insight, internal self-awareness (ISA), and self-reflectiveness (SR) have been found to relate to well-being. The present study sought to determine which dispositional private self-focused attention variables have the most predictive power for subjective well-being as measured by the Satisfaction With Life Scale (E. Diener, R. A. Emmons, R. J. Larsen, & S. Griffin, 1985) and for a eudaemonic form of well-being as measured by the Psychological Well-Being Scale (C. D. Ryff, 1989). A total of 121 college student participants completed an online version of the Self-Consciousness Scale-Revised, the Rumination-Reflection Questionnaire, the Self-Reflection and Insight Scale, the Satisfaction With Life Scale, and the Psychological WellBeing Scale. Results of a multivariate regression analysis using the Self-Consciousness Scale-Revised's (M. F. Scheier & C. S. Carver, 1985) subfactors of SR and ISA, the Rumination-Reflection Questionnaire's (P. D. Trapnell & J. D. Campbell, 1999) subscales of Rumination and Reflection, and the Self-Reflection and Insight Scale's (A. M. Grant, J. Franklin, & P. Langford, 2002) Self-Reflection and Insight subscales revealed that the Insight subscale was the only statistically significant predictor (a positive predictor) for all 6 dimensions of psychological well-being. Insight was also the only significant positive predictor for satisfaction with life. The Rumination subscale was a significant negative predictor for 3 dimensions of psychological well-being, and the Reflection subscale was a significant positive predictor for 1 dimension. Implications of dispositional self-awareness variables and their relation to dimensions of well-being are discussed.
NOAA AVHRR Land Surface Albedo Algorithm Development
NASA Technical Reports Server (NTRS)
Toll, D. L.; Shirey, D.; Kimes, D. S.
1997-01-01
The primary objective of this research is to develop a surface albedo model for the National Oceanic and Atmospheric Administration (NOAA) Advanced Very High Resolution Radiometer (AVHRR). The primary test site is the Konza prairie, Kansas (U.S.A.), used by the International Satellite Land Surface Climatology Project (ISLSCP) in the First ISLSCP Field Experiment (FIFE). In this research, high spectral resolution field spectrometer data was analyzed to simulate AVHRR wavebands and to derive surface albedos. Development of a surface albedo algorithm was completed by analysing a combination of satellite, field spectrometer, and ancillary data. Estimated albedos from the field spectrometer data were compared to reference albedos derived using pyranometer data. Variations from surface anisotropy of reflected solar radiation were found to be the most significant albedo-related error. Additional error or sensitivity came from estimation of a shortwave mid-IR reflectance (1.3-4.0 micro-m) using the AVHRR red and near-IR bands. Errors caused by the use of AVHRR spectral reflectance to estimate both a total visible (0.4-0.7 micro-m) and near-IR (0.7-1.3 micro-m) reflectance were small. The solar spectral integration, using the derived ultraviolet, visible, near-IR and SW mid-IR reflectivities, was not sensitive to many clear-sky changes in atmospheric properties and illumination conditions.
Resonant-cavity light-emitting diodes for optical interconnects
NASA Astrophysics Data System (ADS)
Jin, Xu
This dissertation addresses the issues related to external quantum efficiencies and light coupling efficiency of novel 1.3 mum Resonant-cavity light-emitting diodes (RCLEDs) on GaAs substrates. External quantum efficiency (QE) is defined as the number of extracted photons per injected electrons, i.e., the product of injection efficiency, internal QE, and light extraction efficiency. This study focuses on the latter two terms. Internal QE mainly depends on the properties of the active region quantum wells (QWs) used in the RCLEDs, such as composition, thickness, and strain compensation. GaAsSb/GaAs QW edge-emitting (EE) lasers are characterized experimentally to extract key parameters, such as internal QE and internal loss. With optimized QWs and a novel self-aligned EE lasers process, room temperature continuous wave (CW) operation of GaAsSb EE lasers has been demonstrated for the first time. The highest operational temperature for the EE lasers is 48°C at a wavelength as long as 1260 nm. This result is the best ever reported by a university group. In conventional LEDs, very little light generated by the active region, succeeds in escaping from the semiconductor material due to the small critical angle of total internal reflection. With the use of a resonant cavity, the light extraction efficiency of RCLEDs is significantly improved. Front and back reflectivities, detuning (offset) between resonant-cavity peak and electroluminescence, and electroluminescence linewidth have been identified as key factors influencing light extraction efficiency. Numerical simulations indicate that the fraction of luminescence transmitted through the top mirror of an optimized RCLED is around 9%, which is more than double that of conventional LEDs. This number will be larger when multiple reflections and photon recycling are considered; which are not included in the current model since they are structure dependent. The best GaAsSb/GaAs QW RCLEDs demonstrated in this work have shown narrow spectral linewidths of 7-10 nm, extracted light output power in the range of 200-300 muW, and modulation speed up to 300 MHz. This is the first demonstration of 1.3 muRCLEDs on GaAs substrates with performance comparable to InP based surface-emitting LEDs.
Real time infrared aerosol analyzer
Johnson, Stanley A.; Reedy, Gerald T.; Kumar, Romesh
1990-01-01
Apparatus for analyzing aerosols in essentially real time includes a virtual impactor which separates coarse particles from fine and ultrafine particles in an aerosol sample. The coarse and ultrafine particles are captured in PTFE filters, and the fine particles impact onto an internal light reflection element. The composition and quantity of the particles on the PTFE filter and on the internal reflection element are measured by alternately passing infrared light through the filter and the internal light reflection element, and analyzing the light through infrared spectrophotometry to identify the particles in the sample.
Preston, R C; Bond, A D
1997-01-01
The performance of small-diameter targets suitable for use as oscillating targets for testing the sensitivity of Doppler fetal heartbeat detectors has been systematically studied. Experimental results are presented in the 1.6-3.0 MHz frequency range for the plane-wave reflection loss for a total of 16 targets: spherical balls made of stainless steel; hemispherical-ended rods made of PTFE; and flat-ended rods made of stainless steel, PTFE, polycarbonate, and tungsten carbide. Results show that the fine-structure variation of reflection loss with frequency is greatest in the case of spherical ball targets and least for flat-ended targets. It has been shown that, providing care is taken during manufacture, the reflection loss from a flat-ended target can be predicted using a simple theory based on a plane disc reflector. Tungsten carbide targets consisting of a long rod with a diameter of 1.6 mm tapered down to a cylindrical flat end with a diameter of 0.4, 0.5, and 0.6 mm have been shown to provide reflection losses of between 60 and 40 dB, and to have a smooth variation of reflection loss with frequency. They can also be manufactured in a form that allows no significant interference from the supporting structure and, therefore, are ideal targets to meet the requirements of International Electrotechnical Commission 1266:1995.
NASA Astrophysics Data System (ADS)
Ruthenburg, Travis; Aweda, Tolulope; Park, Simon; Meares, Claude; Land, Donald
2009-03-01
Protein binding/affinity studies are often performed using Surface Plasmon Resonance techniques that don't produce much spectral information. Measurement of protein binding affinity using FTIR is traditionally performed using high protein concentration or deuterated solvent. By immobilizing a protein near the surface of a gold-coated germanium internal reflection element interactions can be measured between an immobilized protein and free proteins or small molecules in aqueous solution. By monitoring the on and off rates of these interactions, the dissociation constant for the system can be determined. The dissociation constant for the molecule Yttrium-DOTA binding to the antibody 2D12.5 system was determined to be 100nM. Results will also be presented from our measurements of Bovine Serum Albumin (BSA) binding to anti-BSA.
50th Annual Scientific Meeting of the British Society for Haematology.
Thomas, Angela E
2010-08-01
The 50th Annual Scientific Meeting of the British Society for Haematology was notable, not only for its golden anniversary, but also because it coincided with the eruption of the Icelandic volcano, Eyjafjallajökull, and the ensuing travel chaos. In total, 28 speakers from overseas were unable to reach Edinburgh, including a significant number of British speakers who were stranded. However, owing to the superb efforts of the conference organisers and Edinburgh International Conference Centre staff, teleconferencing equipment was installed and all speakers were contacted and able to give their talks on time. The program, consisting of simultaneous sessions and plenary lectures, covered not only recent advances in clinical and laboratory hematology, but also reflected on the contribution of British hematology to the international arena over the past 50 years.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohara-Imaizumi, Mica; Aoyagi, Kyota; Nakamichi, Yoko
We simultaneously analyzed insulin granule fusion with insulin fused to green fluorescent protein and the subplasma membrane Ca{sup 2+} concentration ([Ca{sup 2+}]{sub PM}) with the Ca{sup 2+} indicator Fura Red in rat {beta} cells by dual-color total internal reflection fluorescence microscopy. We found that rapid and marked elevation in [Ca{sup 2+}]{sub PM} caused insulin granule fusion mostly from previously docked granules during the high KCl-evoked release and high glucose-evoked first phase release. In contrast, the slow and sustained elevation in [Ca{sup 2+}]{sub PM} induced fusion from newcomers translocated from the internal pool during the low KCl-evoked release and glucose-evoked secondmore » phase release. These data suggest that the pattern of the [Ca{sup 2+}]{sub PM} rise directly determines the types of fusing granules.« less
ERIC Educational Resources Information Center
Charters, Alexander N.
2012-01-01
This article presents the author's reflections on involvement with six UNESCO international conferences on adult education. As adult educators continue to look forward with enthusiasm to the future of adult and continuing education in an increasingly international society, the author argues that they need to continually remember that the mission…
University Employment Transitions in International Performing Arts: The Intern's Story
ERIC Educational Resources Information Center
Carneiro, Maria
2013-01-01
This article reflects my journey as a performing arts student and intern both in Portugal and abroad. It is not intended as a personal journal, but rather a reflection and an aftermath comment on my experiences and learning processes. First it provides a context regarding my university education in a Southern European country, against a previous…
Technology Experiences of Student Interns in a One to One Mobile Program
ERIC Educational Resources Information Center
Cullen, Theresa A.; Karademir, Tugra
2018-01-01
This article describes how a group of student intern teachers (n = 51) in a one to one teacher education iPad program were asked to reflect using Experience Sampling Method (ESM) on their use of technology in the classroom during internship. Interns also completed summative reflections and class discussions. Data collected both in online and…
Cross-phase-modulation-induced temporal reflection and waveguiding of optical pulses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Plansinis, Brent W.; Donaldson, William R.; Agrawal, Govind P.
Cross-phase modulation (XPM) is commonly viewed as a nonlinear process that chirps a probe pulse and modifies its spectrum when an intense pump pulse overlaps with it. Here we present an alternative view of XPM in which the pump pulse creates a moving refractive-index boundary that splits the probe pulse into two parts with distinct optical spectra through temporal reflection and refraction inside a dispersive nonlinear medium. The probe even undergoes a temporal version of total internal reflection for sufficiently intense pump pulses, a phenomenon that can be exploited for making temporal waveguides. In this paper we investigate the practicalmore » conditions under which XPM can be exploited for temporal reflection and waveguiding. The width and shape of pump pulses as well as the nature of medium dispersion at the pump and probe wavelength (normal versus anomalous) play important roles. A super-Gaussian shape of pump pulses is particularly helpful because of its relatively sharp edges. When the pump wavelength lies in the anomalous-dispersion regime, the pump pulse can form a soliton,whose unique properties can be exploited to advantage. We also discuss a potential application of XPM-induced temporal waveguides for compensating timing jitter.« less
Utilizing Diffuse Reflection to Increase the Efficiency of Luminescent Solar Concentrators
NASA Astrophysics Data System (ADS)
Bowser, Seth; Weible, Seth; Solomon, Joel; Schrecengost, Jonathan; Wittmershaus, Bruce
A luminescent solar concentrator (LSC) consists of a high index solid plate containing a fluorescent material that converts sunlight into fluorescence. Utilizing total internal reflection, the LSC collects and concentrates the fluorescence at the plate's edges where it is converted into electricity via photovoltaic solar cells. The lower production costs of LSCs make them an attractive alternative to photovoltaic solar cells. To optimize an LSC's efficiency, a white diffusive surface (background) is positioned behind it. The background allows sunlight transmitted in the first pass to be reflected back through the LSC providing a second chance for absorption. Our research examines how the LSC's performance is affected by changing the distance between the white background and the LSC. An automated linear motion apparatus was engineered to precisely measure this distance and the LSC's electrical current, simultaneously. LSC plates, with and without the presence of fluorescent material and in an isolated environment, showed a maximum current at a distance greater than zero. Further experimentation has proved that the optimal distance results from the background's optical properties and how the reflected light enters the LSC. This material is based upon work supported by the National Science Foundation under Grant Number NSF-ECCS-1306157.
Cross-phase-modulation-induced temporal reflection and waveguiding of optical pulses
Plansinis, Brent W.; Donaldson, William R.; Agrawal, Govind P.
2018-01-31
Cross-phase modulation (XPM) is commonly viewed as a nonlinear process that chirps a probe pulse and modifies its spectrum when an intense pump pulse overlaps with it. Here we present an alternative view of XPM in which the pump pulse creates a moving refractive-index boundary that splits the probe pulse into two parts with distinct optical spectra through temporal reflection and refraction inside a dispersive nonlinear medium. The probe even undergoes a temporal version of total internal reflection for sufficiently intense pump pulses, a phenomenon that can be exploited for making temporal waveguides. In this paper we investigate the practicalmore » conditions under which XPM can be exploited for temporal reflection and waveguiding. The width and shape of pump pulses as well as the nature of medium dispersion at the pump and probe wavelength (normal versus anomalous) play important roles. A super-Gaussian shape of pump pulses is particularly helpful because of its relatively sharp edges. When the pump wavelength lies in the anomalous-dispersion regime, the pump pulse can form a soliton,whose unique properties can be exploited to advantage. We also discuss a potential application of XPM-induced temporal waveguides for compensating timing jitter.« less
Ivannikov, Maxim V.; Sugimori, Mutsuyuki; Llinás, Rodolfo R.
2012-01-01
Synaptic plasticity in many regions of the central nervous system leads to the continuous adjustment of synaptic strength, which is essential for learning and memory. In this study, we show by visualizing synaptic vesicle release in mouse hippocampal synaptosomes that presynaptic mitochondria and specifically, their capacities for ATP production are essential determinants of synaptic vesicle exocytosis and its magnitude. Total internal reflection microscopy of FM1-43 loaded hippocampal synaptosomes showed that inhibition of mitochondrial oxidative phosphorylation reduces evoked synaptic release. This reduction was accompanied by a substantial drop in synaptosomal ATP levels. However, cytosolic calcium influx was not affected. Structural characterization of stimulated hippocampal synaptosomes revealed that higher total presynaptic mitochondrial volumes were consistently associated with higher levels of exocytosis. Thus, synaptic vesicle release is linked to the presynaptic ability to regenerate ATP, which itself is a utility of mitochondrial density and activity. PMID:22772899
Nimbus-7 TOMS Version 7 Calibration
NASA Technical Reports Server (NTRS)
Wellemeyer, C. G.; Taylor, S. L.; Jaross, G.; DeLand, M. T.; Seftor, C. J.; Labow, G.; Swissler, T. J.; Cebula, R. P.
1996-01-01
This report describes an improved instrument characterization used for the Version 7 processing of the Nimbus-7 Total Ozone Mapping Spectrometer (TOMS) data record. An improved internal calibration technique referred to as spectral discrimination is used to provide long-term calibration precision of +/- 1%/decade in total column ozone amount. A revised wavelength scale results in a day one calibration that agrees with other satellite and ground-based measurements of total ozone, while a wavelength independent adjustment of the initial radiometric calibration constants provides good agreement with surface reflectivity measured by other satellite-borne ultraviolet measurements. The impact of other aspects of the Nimbus-7 TOMS instrument performance are also discussed. The Version 7 data should be used in all future studies involving the Nimbus-7 TOMS measurements of ozone. The data are available through the NASA Goddard Space Flight Center's Distributive Active Archive Center (DAAC).
The TORCH detector R&D: Status and perspectives
NASA Astrophysics Data System (ADS)
Gys, T.; Brook, N.; García, L. Castillo; Cussans, D.; Föhl, K.; Forty, R.; Frei, C.; Gao, R.; Harnew, N.; Piedigrossi, D.; Rademacker, J.; García, A. Ros; van Dijk, M.
2017-12-01
TORCH (Timing Of internally Reflected CHerenkov photons) is a time-of-flight detector for particle identification at low momentum. It has been originally proposed for the LHCb experiment upgrade. TORCH is using plates of quartz radiator in a modular design. A fraction of the Cherenkov photons produced by charged particles passing through this radiator propagate by total internal reflection, they emerge at the edges and are subsequently focused onto fast, position-sensitive single-photon detectors. The recorded position and arrival time of the photons are used to precisely reconstruct their trajectory and propagation time in the quartz. The on-going R&D programme aims at demonstrating the TORCH basic concept through the realization of a full detector module and has been organized on the following main development lines: micro-channel plate photon detectors featuring the required granularity and lifetime, dedicated fast front-end electronics preserving the picosecond timing information provided by single photons, and high-quality quartz radiator and focussing optics minimizing photon losses. The present paper reports on the TORCH results successfully achieved in the laboratory and in charged particle beam tests. It will also introduce the latest developments towards a final full-scale module prototype.
Trache, Andreea; Meininger, Gerald A
2005-01-01
A novel hybrid imaging system is constructed integrating atomic force microscopy (AFM) with a combination of optical imaging techniques that offer high spatial resolution. The main application of this instrument (the NanoFluor microscope) is the study of mechanotransduction with an emphasis on extracellular matrix-integrin-cytoskeletal interactions and their role in the cellular responses to changes in external chemical and mechanical factors. The AFM allows the quantitative assessment of cytoskeletal changes, binding probability, adhesion forces, and micromechanical properties of the cells, while the optical imaging applications allow thin sectioning of the cell body at the coverslip-cell interface, permitting the study of focal adhesions using total internal reflection fluorescence (TIRF) and internal reflection microscopy (IRM). Combined AFM-optical imaging experiments show that mechanical stimulation at the apical surface of cells induces a force-generating cytoskeletal response, resulting in focal contact reorganization on the basal surface that can be monitored in real time. The NanoFluor system is also equipped with a novel mechanically aligned dual camera acquisition system for synthesized Forster resonance energy transfer (FRET). The integrated NanoFluor microscope system is described, including its characteristics, applications, and limitations.
Value of Reflected Light Microscopy in Teaching.
ERIC Educational Resources Information Center
Pasteris, Jill Dill
1983-01-01
Briefly reviews some optical and other physical properties of minerals that can be determined in reflected/incident light. Topics include optical properties of minerals, reflectance, internal reflections, color, bireflectance and reflection pleochroism, anisotropism, zonation, and reflected light microscopy as a teaching tool in undergraduate…
Aalboe, Joanna A; Schumacher, Mitzi M
2016-01-01
The aim of this study was to explore the internal structure of an instrument assessing dental students' confidence in their ability to communicate with patients in six specific circumstances (anxious, in pain, etc.) using exploratory factor analysis. In a Communication in the Dental Health Care Setting course at a U.S. dental school, second-year dental students in two years (2013 and 2014) responded to the six items on a survey instrument. Of the total 123 students, 122 fully completed the instrument, for a response rate of 99%. Analysis of the results identified a unidimensional scale with regards to patient-specific communication self-efficacy and explained 74% of the total variance. The scale had good internal consistency reflected by high Cronbach's alpha (α=0.929, 95% CI [0.907, 0.947]). These findings suggest the instrument may be a useful tool in assessing the development of patient communication skills in second-year dental students following a course in communication. Further exploration utilizing confirmatory analysis, determining predictive validity, and assessing convergent and discriminant evidence is warranted.
Wallerstein, R S
1998-06-01
Ever since 1938 the American Psychoanalytic Association has had a special autonomous relationship within the IPA accorded to no other component organisation. This Regional Association status has had two main features: (1) total internal control over training standards and membership criteria, with no accountability to the IPA; and (2) an 'exclusive franchise', so that the IPA was barred from recognising any other component within the United States. This unique Regional Association status reflected the resolution at the time (1938) of the long-standing controversy between the IPA and the American over the issue of 'lay analysis', and remained unaltered for half a century until, with the resolution of the 3 1/2-year long law-suit against the American (and secondarily against the IPA) in 1988, the Regional Association agreement was modified (but not totally abrogated) by the American's giving up the 'exclusive franchise' aspect (thus permitting IPA recognition of psychoanalytic groups in the US organised outside the American), but still retaining its internal full control over training and membership. The meanings and consequences for psychoanalysis of this special status of the American are explored.
NASA Astrophysics Data System (ADS)
Liu, Xudong; Chen, Xuequan; Parrott, Edward P. J.; Han, Chunrui; Humbert, Georges; Crunteanu, Aurelian; Pickwell-MacPherson, Emma
2018-05-01
Active broadband terahertz (THz) polarization manipulation devices are challenging to realize, but also of great demand in broadband terahertz systems. Vanadium dioxide (VO2) shows a promising phase transition for active control of THz waves and provides broadband polarization characteristics when integrated within grating-type structures. We creatively combine a VO2-based grating structure with a total internal reflection (TIR) geometry providing a novel interaction mechanism between the electromagnetic waves and the device, to realize a powerful active broadband THz polarization-controlling device. The device is based on a Si-substrate coated with a VO2 layer and a metal grating structure on top, attached to a prism for generating the TIR condition on the Si-VO2-grating interface. The grating is connected to electrodes for electrically switching the VO2 between its insulating and conducting phases. By properly selecting the incident angle of the THz waves, the grating direction, and the incident polarization state, we first achieved a broadband intensity modulator under a fused silica prism with an average modulation depth of 99.75% in the 0.2-1.1 THz region. Additionally, we realized an active ultra-broadband quarter-wave converter under a Si prism that can be switched between a 45° linear rotator and a quarter wave converter in the 0.8-1.5 THz region. This is the first demonstration of an active quarter-wave converter with ultra-broad bandwidth performance. Our work shows a highly flexible and multifunctional polarization-controlling device for broadband THz applications.
Sund, S E; Axelrod, D
2000-01-01
Although reversible chemistry is crucial to dynamical processes in living cells, relatively little is known about relevant chemical kinetic rates in vivo. Total internal reflection/fluorescence recovery after photobleaching (TIR/FRAP), an established technique previously demonstrated to measure reversible biomolecular kinetic rates at surfaces in vitro, is extended here to measure reversible biomolecular kinetic rates of actin at the cytofacial (subplasma membrane) surface of living cells. For the first time, spatial imaging (with a charge-coupled device camera) is used in conjunction with TIR/FRAP. TIR/FRAP imaging produces both spatial maps of kinetic parameters (off-rates and mobile fractions) and estimates of kinetic correlation distances, cell-wide kinetic gradients, and dependences of kinetic parameters on initial fluorescence intensity. For microinjected rhodamine actin in living cultured smooth muscle (BC3H1) cells, the unbinding rate at or near the cytofacial surface of the plasma membrane (averaged over the entire cell) is measured at 0.032 +/- 0.007 s(-1). The corresponding rate for actin marked by microinjected rhodamine phalloidin is very similar, 0.033 +/- 0.013 s(-1), suggesting that TIR/FRAP is reporting the dynamics of entire filaments or protofilaments. For submembrane fluorescence-marked actin, the intensity, off-rate, and mobile fraction show a positive correlation over a characteristic distance of 1-3 microm and a negative correlation over larger distances greater than approximately 7-14 microm. Furthermore, the kinetic parameters display a statistically significant cell-wide gradient, with the cell having a "fast" and "slow" end with respect to actin kinetics. PMID:10969025
NASA Astrophysics Data System (ADS)
Marguí, Eva; Hidalgo, Manuela; Migliori, Alessandro; Leani, Juan José; Queralt, Ignasi; Kallithrakas-Kontos, Nikolaos; Streli, Christina; Prost, Josef; Karydas, Andreas Germanos
2018-07-01
The aim of the work is to present a systematic evaluation of the analytical capabilities of the new X-ray fluorescence facility jointly operated between the International Atomic Energy Agency and the Elettra Sincrotrone Trieste for multipurpose total reflection X-ray fluorescence analysis. The analytical performance of the XRF beamline end-station (IAEAXspe) was systematically evaluated under TXRF excitation geometry by analyzing different types of aqueous (lake, waste and fresh water) and solid (soil, vegetal, biological) certified reference materials using an excitation energy of 13.0 keV (for the purpose of multielemental analysis). The results obtained for both types of samples in terms of limits of detection and accuracy were also compared with those obtained using laboratory X-ray tube based TXRF systems with different features (including Mo and W X-ray tube systems). Taking advantage of the possibility to work under high vacuum, the IAEAXspe set-up instrumental sensitivity was also determined using an excitation energy of 6.2 keV to explore the possibilities for light elements determination. A clear improvement of the element detection limits is achieved when comparing this facility to conventional X-ray tube based TXRF systems highlighting the benefits of using the monoenergetic synchrotron exciting radiation and the ultra-high vacuum chamber in comparison with conventional laboratory systems. The results of the present work are discussed in view of further exploitation of the facility for different environmental and biological related applications.
NASA Astrophysics Data System (ADS)
Cardoso Dos Santos, Marcelina; Vézy, Cyrille; Jaffiol, Rodolphe
2016-02-01
Total Internal Reflection Fluorescence Microscopy (TIRFM) is a widespread technique to study cellular process occurring near the contact region with the glass substrate. In this field, determination of the accurate distance from the surface to the plasma membrane constitutes a crucial issue to investigate the physical basis of cellular adhesion process. However, quantitative interpretation of TIRF pictures regarding the distance z between a labeled membrane and the substrate is not trivial. Indeed, the contrast of TIRF images depends on several parameters more and less well known (local concentration of dyes, absorption cross section, angular emission pattern…). The strategy to get around this problem is to exploit a series of TIRF pictures recorded at different incident angles in evanescent regime. This technique called variable-angle TIRF microscopy (vaTIRFM), allowing to map the membrane-substrate separation distance with a nanometric resolution (10-20 nm). vaTIRFM was developed by Burmeister, Truskey and Reichert in the early 1990s with a prism-based TIRF setup [Journal of Microscopy 173, 39-51 (1994)]. We propose a more convenient prismless setup, which uses only a rotatable mirror to adjust precisely the laser beam on the back focal plane of the oil immersion objective (no azimuthal scanning is needed). The series of TIRF images permit us to calculate accurately membrane-surface distances in each pixel. We demonstrate that vaTIRFM are useful to quantify the adhesion of living cells for specific and unspecific membrane-surface interactions, achieved on various functionalized substrates with polymers (BSA, poly-L-lysin) or extracellular matrix proteins (collagen and fibronectin).
Flachenecker, P; Vogel, U; Simeoni, M C; Auquier, P; Rieckmann, P
2011-10-01
The existing health-related quality of life questionnaires on multiple sclerosis (MS) only partially reflect the patient's point of view on the reduction of activities of daily living. Their development and validation was not performed in different languages. That is what prompted the development of the Multiple Sclerosis International Quality of Life (MusiQoL) Questionnaire as an international multidimensional measurement instrument. This paper presents this new development and the results of the German subgroup versus the total international sample. A total of 1,992 MS patients from 15 countries, including 209 German patients, took part in the study between January 2004 and February 2005. The patients took the MusiQoL survey at baseline and at 21±7 days as well as completing a symptom-related checklist and the SF-36 short form survey. Demographics, history and MS classification data were also generated. Reproducibility, sensitivity, convergent and discriminant validity were analysed. Convergent and discriminant validity and reproducibility were satisfactory for all dimensions of the MusiQoL. The dimensional scores correlated moderately but significantly with the SF-36 scores, but showed a discriminant validity in terms of gender, socioeconomic status and health status that was more pronounced in the overall population than in the German subpopulation. The highest correlations were observed between the MusiQoL dimension of activities of daily living and the Expanded Disability Status Scale (EDSS). The results of this study confirm the validity and reliability of MusiQoL as an instrument for measuring the quality of life of German and international MS patients.
Numerical analysis of lateral illumination lightpipes using elliptical grooves
NASA Astrophysics Data System (ADS)
Sánchez-Guerrero, Guillermo E.; Viera-González, Perla M.; Martínez-Guerra, Edgar; Ceballos-Herrera, Daniel E.
2017-09-01
Lightpipes are used for illumination in applications such as back-lighting or solar cell concentrators due to the high irradiance uniformity, but its optimal design requires several parameters. This work presents a procedure to design a square lightpipe to control the light-extraction on its lateral face using commercial LEDs placed symmetrically in the lightpipe frontal face. We propose the use of grooves using total internal reflection placed successively in the same face of extraction to control the area of emission. The LED area of emission is small compared with the illuminated area, and, as expected, the lateral face total power is attenuated. These grooves reduce the optical elements in the system and can control areas of illumination. A mathematical and numerical analysis are presented to determine the dependencies on the light-extraction.
The effects of age and type of carrying task on lower extremity kinematics
Gillette, Jason C.; Stevermer, Catherine A.; Miller, Ross H.; Meardon, Stacey A.; Schwab, Charles V.
2009-01-01
The purpose of this study was to determine the effects of age, load amount, and load symmetry on lower extremity kinematics during carrying tasks. Forty-two participants in four age groups (8-10 years, 12-14 years, 15-17 years, and adults) carried loads of 0%, 10%, and 20% body weight (BW) in large or small buckets unilaterally and bilaterally. Reflective markers were tracked to determine total joint ROM and maximum joint angles during the stance phase of walking. Maximum hip extension, hip adduction, and hip internal rotation angles were significantly greater for each of the child/adolescent age groups as compared to adults. In addition, maximum hip internal rotation angles significantly increased when carrying a 20% BW load. The observation that the 8-10 year old age group carried the lightest absolute loads and still displayed the highest maximum hip internal rotation angles suggests a particular necessity in setting carrying guidelines for the youngest children. PMID:20191410
Laan, Ellen; Rellini, Alessandra H; Barnes, Tricia
2013-01-01
As the field of sexual medicine evolves, it is important to continually improve patient care by developing contemporary "standard operating procedures" (SOPs), reflecting the consensus view of experts in sexual medicine. Few, if any, consensus SOPs have been developed for the diagnosis and treatment of Female Orgasmic Disorder (FOD). The objective is to provide standard operating procedures for FOD. The SOP Committee was composed of a chair, selected by the International Society for the Study of Sexual Medicine, and two additional experts. To inform its key recommendations, the Committee used systematic reviews of available evidence and discussions during a group meeting, conference calls and e-mail communications. The Committee received no corporate funding or remuneration. A total of 12 recommendations for the assessment and treatment of FOD were generated, including suggestions for further research. Evidence-based, practice recommendations for the treatment of FOD are provided that will hopefully inform clinical decision making for those treating this common condition. © 2012 International Society for Sexual Medicine.
NASA Astrophysics Data System (ADS)
Stosnach, Hagen; Mages, Margarete
2009-04-01
In clinical service laboratories, one of the most common analytical tasks with regard to inorganic traces is the determination of the nutrition-relevant elements Fe, Cu, Zn, and Se. Because of the high numbers of samples and the commercial character of these analyses, a time-consuming sample preparation must be avoided. In this presentation, the results of total reflection X-ray fluorescence measurements with a low-power system and different sample preparation procedures are compared with those derived from analysis with common methods like Atomic Absorption Spectroscopy (AAS) and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS). The results of these investigations indicate that the optimal total reflection X-ray fluorescence analysis of the nutrition-relevant elements Fe, Cu, Zn, and Se can be performed by preparing whole blood and serum samples after dilution with ultrapure water and transferring 10 μl of internally standardized sample to an unsiliconized quartz glass sample carrier with subsequent drying in a laboratory oven. Suitable measurement time was found to be 600 s. The enhanced sample preparation by means of microwave or open digestion, in parts combined with cold plasma ashing, led to an improvement of detection limits by a factor of 2 for serum samples while for whole blood samples an improvement was only observed for samples prepared by means of microwave digestion. As the matrix elements P, S, Cl, and for whole blood Fe have a major influence on the detection limits, most probably a further enhancement of analytical quality requires the removal of the organic matrix. However, for the routine analysis of the nutrition-relevant elements, the dilution preparation was found to be sufficient.
Lindahl, G; Lundström, K; Tornberg, E
2001-10-01
The colour of loin, M. longissimus dorsi (LD), and ham, M. biceps femoris (BF), from pure breed Hampshire, Swedish Landrace and Swedish Yorkshire pigs was studied. The contribution of the pigment content, the myoglobin forms deoxymyoglobin (Mb), oxymyoglobin (MbO) and metmyoglobin (MetMb) and the internal reflectance to the colour of pork of normal meat quality was evaluated using partial least squares regression (PLS). The colour of LD and BF from the Hampshire breed was more red and yellow and more saturated than the colour of the same muscles from the Swedish Landrace and the Swedish Yorkshire breeds. Furthermore, BF from Hampshire was darker than BF from the other two breeds. These differences in colour were related to the lower pH in Hampshire, resulting in more blooming and in higher internal reflectance, and to the higher pigment content. The colour of BF was darker and more red than the colour of LD within each breed. No colour difference was found between gilts and castrates within each breed. Most of the variation (86-90%) in lightness (L* value), redness (a* value) and yellowness (b* value), chroma (saturation) and hue angle of pork of normal meat quality was explained by the pigment content, myoglobin forms and internal reflectance. The L* value, a* value, chroma and hue angle were influenced by both the pigment content and by the myoglobin forms to almost the same extent, while the internal reflectance was of no significance to these colour parameters. The b* value was influenced most by the myoglobin forms, less by the internal reflectance and almost not at all by the pigment content.
The SR-71 Test Bed Aircraft: A Facility for High-Speed Flight Research
NASA Technical Reports Server (NTRS)
Corda, Stephen; Moes, Timothy R.; Mizukami, Masashi; Hass, Neal E.; Jones, Daniel; Monaghan, Richard C.; Ray, Ronald J.; Jarvis, Michele L.; Palumbo, Nathan
2000-01-01
The SR-71 test bed aircraft is shown to be a unique platform to flight-test large experiments to supersonic Mach numbers. The test bed hardware mounted on the SR-71 upper fuselage is described. This test bed hardware is composed of a fairing structure called the "canoe" and a large "reflection plane" flat plate for mounting experiments. Total experiment weights, including the canoe and reflection plane, as heavy as 14,500 lb can be mounted on the aircraft and flight-tested to speeds as fast as Mach 3.2 and altitudes as high as 80,000 ft. A brief description of the SR-71 aircraft is given, including details of the structural modifications to the fuselage, modifications to the J58 engines to provide increased thrust, and the addition of a research instrumentation system. Information is presented based on flight data that describes the SR-71 test bed aerodynamics, stability and control, structural and thermal loads, the canoe internal environment, and reflection plane flow quality. Guidelines for designing SR-71 test bed experiments are also provided.
Composite Yb:YAG/SiC-prism thin disk laser.
Newburgh, G A; Michael, A; Dubinskii, M
2010-08-02
We report the first demonstration of a Yb:YAG thin disk laser wherein the gain medium is intracavity face-cooled through bonding to an optical quality SiC prism. Due to the particular design of the composite bonded Yb:YAG/SiC-prism gain element, the laser beam impinges on all refractive index interfaces inside the laser cavity at Brewster's angles. The laser beam undergoes total internal reflection (TIR) at the bottom of the Yb(10%):YAG thin disk layer in a V-bounce cavity configuration. Through the use of TIR and Brewster's angles, no optical coatings, either anti-reflective (AR) or highly reflective (HR), are required inside the laser cavity. In this first demonstration, the 936.5-nm diode pumped laser performed with approximately 38% slope efficiency at 12 W of quasi-CW (Q-CW) output power at 1030 nm with a beam quality measured at M(2) = 1.5. This demonstration opens up a viable path toward novel thin disk laser designs with efficient double-sided room-temperature heatsinking via materials with the thermal conductivity of copper on both sides of the disk.
"Beginning with the end in mind": imagining personal retirement speeches to promote professionalism.
Yu, Eunice; Wright, Scott M
2015-06-01
The goal of teaching professionalism in medicine is to transform a theoretical concept into an internalized and actualized identity. Many trainees struggle with professionalism in the abstract, particularly when instruction methods are didactic and disconnected from personal experience. The authors aim to demonstrate the feasibility of having interns frame a personal definition of professionalism based on a reflective technique called "beginning with the end in mind." Interns composed remarks that might be used to introduce them at their own retirement ceremony following a career in medicine. This "career eulogies" exercise was introduced to groups of six interns during the first third of the internship year as part of a two-week curriculum focused on professional development. Two investigators independently coded the written introductions, identifying emergent themes through content analysis. Of the 19 interns in an internal medicine residency program (2012-13), 17 participated in the exercise. Six themes emerged from the data: aligning behaviors with core values, achieving excellence in medicine, changing the world and giving back, valuing teamwork and relationships, realizing work-life balance, and appreciating a career in medicine. These themes correlate with accepted published definitions of professionalism. The personal reflections produced through this exercise allow physicians to begin to formulate their professional self-conception. Extensions of this work might include linking such forms of critical reflection to individualized learning plans and updating the speeches over time. Further research on "reflecting forward" may determine its impact as a complement to traditional narrative reflection.
Diffraction efficiency growth of nano-scale holographic recording produced in a corona discharge
NASA Astrophysics Data System (ADS)
Bodurov, I.; Yovcheva, T.; Vlaeva, I.; Viraneva, A.; Todorov, R.; Spassov, G.; Sainov, S.
2012-12-01
The nano-scale holographic gratings ware recorded in 29 nm and 56 nm thick As2S3 films. The chalcogenide layers were deposited on a transparent chromium electrode with thickness 10 nm, produced on a glass substrate. Both chromium and chalcogenide films were deposited in one vacuum cycle by e-beam and thermal evaporation, respectively. The diode 532 nm diode laser was used as a light source in the present holographic experiments. The total internal reflection arrangement (Stetson-Nassenstein) was used in holographic recordings. The reference beam was totally reflected from the air-As2S3 boundary surface by an input glass prism. The object beam was normally incident on the recording medium. The corona charging was performed by a needle fixed at the distance of 1 cm from the holographic recording medium by applying a - 5 kV voltage. The diffraction efficiency increased from 9 to 30 times when the corona discharge was applied during the holographic recording, in comparison to the uncharged recording. The possible reason of the observed effect is discussed on the basis of the Franz-Keldysh effect and Moss rule.
Stray-light suppression in a reflecting white-light coronagraph
NASA Technical Reports Server (NTRS)
Romoli, Marco; Weiser, Heinz; Gardner, Larry D.; Kohl, John L.
1993-01-01
An analysis of stray-light suppression in the white-light channel of the Ultraviolet Coronagraph Spectrometer experiment for the Solar and Heliospheric Observatory is reported. The white-light channel consists of a reflecting telescope with external and internal occultation and a polarimeter section. Laboratory tests and analytical methods are used to perform the analysis. The various stray-light contributions are classified in two main categories: the contribution from sunlight that passes directly through the entrance aperture and the contribution of sunlight that is diffracted by the edges of the entrance aperture. Values of the stray-light contributions from various sources and the total stray-light level for observations at heliocentric heights from 1.4 to 5 solar radii are derived. Anticipated signal-to-stray-light ratios are presented together with the effective stray-light rejection by the polarimeter, demonstrating the efficacy of the stray-light suppression design.
Expanded beam non-imaging fiber optic connector
Jannson, Tommasz; Jannson, Joanna; Yeung, Peter
1990-01-01
There is disclosed an expanded beam fiber to fiber connector, based on non-imaging optic principles for coupling light beams from one optical fiber to another. The system consists of two identical connector parts, referred to herein as a collimating part and a concentrating part, each having a preferred partially curved reflective boundary surface for minimizing power loss and surrounding either a hollow space or a space filled with a uniform transparent medium. In one embodiment the boundary is metallic while in a second embodiment the boundary is in the form of an interface allowing total internal reflection. In both the hollow and filled case a lens may be located at the expanded end of both the collimater part and the concentrator part forming the connector. The connector is preferably located in a housing in order to protect and preserve the mechanical stability of the coupler.
Expanded beam non-imaging fiber optic connector
Jannson, T.; Jannson, J.; Yeung, P.
1990-02-06
There is disclosed an expanded beam fiber to fiber connector, based on non-imaging optic principles for coupling light beams from one optical fiber to another. The system consists of two identical connector parts, referred to herein as a collimating part and a concentrating part, each having a preferred partially curved reflective boundary surface for minimizing power loss and surrounding either a hollow space or a space filled with a uniform transparent medium. In one embodiment the boundary is metallic while in a second embodiment the boundary is in the form of an interface allowing total internal reflection. In both the hollow and filled case a lens may be located at the expanded end of both the collimator part and the concentrator part forming the connector. The connector is preferably located in a housing in order to protect and preserve the mechanical stability of the coupler. 13 figs.
Applying the ICF to identify requirements for students with Asperger syndrome in higher education.
Adolfsson, Margareta; Simmeborn Fleischer, Ann
2015-06-01
Higher education requires more than academic skills and everyday student-life can be stressful. Students with Asperger syndrome (AS) may need support to manage their education due to difficulties in social functioning. As preparation for the development of a structured tool to guide student and coordinator dialogues at Swedish universities, this study aimed to identify ICF categories that reflect requirements in everyday student-life for students with AS. Using descriptive qualitative approach, information in documents reflecting the perspectives of university students, international classifications, user/health organisations and education authorities were linked to ICF codes. In total, 114 ICF categories were identified, most of which related to learning, tasks and demands, communication and interactions. Students with AS need varying accommodations to be successful in higher education. In the future, ICF-based code sets, including demands on student roles, can be used as checklists to describe functioning and needs for support.
Lu, Zhaolin; Prather, Dennis W
2004-08-01
We present a method for parallel coupling from a single-mode fiber, or fiber ribbon, into a silicon-on-insulator waveguide for integration with silicon optoelectronic circuits. The coupler incorporates the advantages of the vertically tapered waveguides and prism couplers, yet offers the flexibility of planar integration. The coupler can be fabricated by use of either wafer polishing technology or gray-scale photolithography. When optimal coupling is achieved in our experimental setup, the coupler can be packaged by epoxy bonding to form a fiber-waveguide parallel coupler or connector. Two-dimensional electromagnetic calculation predicts a coupling efficiency of 77% (- 1.14-dB insertion loss) for a silicon-to-silicon coupler with a uniform tunnel layer. The coupling efficiency is experimentally achieved to be 46% (-3.4-dB insertion loss), excluding the loss in silicon and the reflections from the input surface and the output facet.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Zhichao; Wu, Shuang; Liu, Bo, E-mail: lbo@tongji.edu.cn
2015-06-15
Soft-X-ray interference lithography is utilized in combination with atomic layer deposition to prepare photonic crystal structures on the surface of Bi{sub 4}Ge{sub 3}O{sub 12} (BGO) scintillator in order to extract the light otherwise trapped in the internal of scintillator due to total internal reflection. An enhancement with wavelength- and emergence angle-integration by 95.1% has been achieved. This method is advantageous to fabricate photonic crystal structures with large-area and high-index-contrast which enable a high-efficient coupling of evanescent field and the photonic crystal structures. Generally, the method demonstrated in this work is also suitable for many other light emitting devices where amore » large-area is required in the practical applications.« less
Internal stress induced natural self-chemisorption of ZnO nanostructured films
Chi, Po-Wei; Su, Chih-Wei; Wei, Da-Hua
2017-01-01
The energetic particles bombardment can produce large internal stress in the zinc oxide (ZnO) thin film, and it can be used to intentionally modify the surface characteristics of ZnO films. In this article, we observed that the internal stress increased from −1.62 GPa to −0.33 GPa, and the naturally wettability of the textured ZnO nanostructured films changed from hydrophobicity to hydrophilicity. According to analysis of surface chemical states, the naturally controllable wetting behavior can be attributed to hydrocarbon adsorbates on the nanostructured film surface, which is caused by tunable internal stress. On the other hand, the interfacial water molecules near the surface of ZnO nanostructured films have been identified as hydrophobic hydrogen structure by Fourier transform infrared/attenuated total reflection. Moreover, a remarkable near-band-edge emission peak shifting also can be observed in PL spectra due to the transition of internal stress state. Furthermore, our present ZnO nanostructured films also exhibited excellent transparency over 80% with a wise surface wetting switched from hydrophobic to hydrophilic states after exposing in ultraviolet (UV) surroundings. Our work demonstrated that the internal stress of the thin film not only induced natural wettability transition of ZnO nanostructured films, but also in turn affected the surface properties such as surface chemisorption. PMID:28233827
Internal stress induced natural self-chemisorption of ZnO nanostructured films
NASA Astrophysics Data System (ADS)
Chi, Po-Wei; Su, Chih-Wei; Wei, Da-Hua
2017-02-01
The energetic particles bombardment can produce large internal stress in the zinc oxide (ZnO) thin film, and it can be used to intentionally modify the surface characteristics of ZnO films. In this article, we observed that the internal stress increased from -1.62 GPa to -0.33 GPa, and the naturally wettability of the textured ZnO nanostructured films changed from hydrophobicity to hydrophilicity. According to analysis of surface chemical states, the naturally controllable wetting behavior can be attributed to hydrocarbon adsorbates on the nanostructured film surface, which is caused by tunable internal stress. On the other hand, the interfacial water molecules near the surface of ZnO nanostructured films have been identified as hydrophobic hydrogen structure by Fourier transform infrared/attenuated total reflection. Moreover, a remarkable near-band-edge emission peak shifting also can be observed in PL spectra due to the transition of internal stress state. Furthermore, our present ZnO nanostructured films also exhibited excellent transparency over 80% with a wise surface wetting switched from hydrophobic to hydrophilic states after exposing in ultraviolet (UV) surroundings. Our work demonstrated that the internal stress of the thin film not only induced natural wettability transition of ZnO nanostructured films, but also in turn affected the surface properties such as surface chemisorption.
Internal stress induced natural self-chemisorption of ZnO nanostructured films.
Chi, Po-Wei; Su, Chih-Wei; Wei, Da-Hua
2017-02-24
The energetic particles bombardment can produce large internal stress in the zinc oxide (ZnO) thin film, and it can be used to intentionally modify the surface characteristics of ZnO films. In this article, we observed that the internal stress increased from -1.62 GPa to -0.33 GPa, and the naturally wettability of the textured ZnO nanostructured films changed from hydrophobicity to hydrophilicity. According to analysis of surface chemical states, the naturally controllable wetting behavior can be attributed to hydrocarbon adsorbates on the nanostructured film surface, which is caused by tunable internal stress. On the other hand, the interfacial water molecules near the surface of ZnO nanostructured films have been identified as hydrophobic hydrogen structure by Fourier transform infrared/attenuated total reflection. Moreover, a remarkable near-band-edge emission peak shifting also can be observed in PL spectra due to the transition of internal stress state. Furthermore, our present ZnO nanostructured films also exhibited excellent transparency over 80% with a wise surface wetting switched from hydrophobic to hydrophilic states after exposing in ultraviolet (UV) surroundings. Our work demonstrated that the internal stress of the thin film not only induced natural wettability transition of ZnO nanostructured films, but also in turn affected the surface properties such as surface chemisorption.
Monge-Nájera, Julián; Ho, Yuh-Shan
2012-12-01
Despite of its small size, the Central American country of Costa Rica is internationally recognized as one of the world leaders in conservation and as the Central American leader in science. There have been no recent studies on the country's scientific production. The objective of this study was to analyze the Costa Rican scientific output as represented in the Science Citation Index Expanded. All documents with "Costa Rica" in the address field from 1981 to 2010 were included (total 6 801 publications). Articles (79%) were more frequent than other types of publication and were mostly in English (83%). Revista de Biología Tropical published the most articles (17%), followed by Toxicon and Turrialba (2.5%). The New England Journal of Medicine had the highest impact factor (53.484) with nine articles. Of 5 343 articles with known institutional address, 63%were internationally collaborative articles (most with the USA) with h index 91 and citation per publication 18. A total of 81% of all articles were inter-institutionally collaborative articles, led by the Universidad de Costa Rica. This reflects research and education agreements among these countries. Universidad de Costa Rica ranked top one in inter-institutionally collaborative articles, the rank of the total inter-institutionally collaborative articles, and the rank of first author articles and corresponding author articles. Studied subjects and journals in our sample are in agreement with dominant science fields and journals in Costa Rica. Articles with the highest citation were published in New England Journal of Medicine. The largest citation of medical articles reflects the general interest and wider readership of this subject. All corresponding and first authors of the high impact articles were not from Costa Rica. In conclusion, the scientific output of Costa Rican authors is strong in the areas related to conservation but the impact is higher for biomedical articles, and Costa Rican authors need to improve their position within research teams.
DeRocco, Vanessa; Anderson, Trevor; Piehler, Jacob; Erie, Dorothy A; Weninger, Keith
2010-11-01
To enable studies of conformational changes within multimolecular complexes, we present a simultaneous, four-color single molecule fluorescence methodology implemented with total internal reflection illumination and camera-based, wide-field detection. We further demonstrate labeling histidine-tagged proteins noncovalently with Tris-nitrilotriacetic acid (Tris-NTA)-conjugated dyes to achieve single molecule detection. We combine these methods to colocalize the mismatch repair protein MutSα on DNA while monitoring MutSα-induced DNA bending using Förster resonance energy transfer (FRET) and to monitor assembly of membrane-tethered SNARE protein complexes.
DeRocco, Vanessa C.; Anderson, Trevor; Piehler, Jacob; Erie, Dorothy A.; Weninger, Keith
2010-01-01
To allow studies of conformational changes within multi-molecular complexes, we present a simultaneous, 4-color single molecule fluorescence methodology implemented with total internal reflection illumination and camera based, wide-field detection. We further demonstrate labeling histidine-tagged proteins non-covalently with tris-Nitrilotriacetic acid (tris-NTA) conjugated dyes to achieve single molecule detection. We combine these methods to co-localize the mismatch repair protein MutSα on DNA while monitoring MutSα-induced DNA bending using Förster resonance energy transfer (FRET) and to monitor assembly of membrane-tethered SNARE protein complexes. PMID:21091445
Optics of two-stage photovoltaic concentrators with dielectric second stages.
Ning, X; O'Gallagher, J; Winston, R
1987-04-01
Two-stage photovoltaic concentrators with Fresnel lenses as primaries and dielectric totally internally reflecting nonimaging concentrators as secondaries are discussed. The general design principles of such two-stage systems are given. Their optical properties are studied and analyzed in detail using computer ray trace procedures. It is found that the two-stage concentrator offers not only a higher concentration or increased acceptance angle, but also a more uniform flux distribution on the photovoltaic cell than the point focusing Fresnel lens alone. Experimental measurements with a two-stage prototype module are presented and compared to the analytical predictions.
Review of infrared scene projector technology-1993
NASA Astrophysics Data System (ADS)
Driggers, Ronald G.; Barnard, Kenneth J.; Burroughs, E. E.; Deep, Raymond G.; Williams, Owen M.
1994-07-01
The importance of testing IR imagers and missile seekers with realistic IR scenes warrants a review of the current technologies used in dynamic infrared scene projection. These technologies include resistive arrays, deformable mirror arrays, mirror membrane devices, liquid crystal light valves, laser writers, laser diode arrays, and CRTs. Other methods include frustrated total internal reflection, thermoelectric devices, galvanic cells, Bly cells, and vanadium dioxide. A description of each technology is presented along with a discussion of their relative benefits and disadvantages. The current state of each methodology is also summarized. Finally, the methods are compared and contrasted in terms of their performance parameters.
Coupling system to a microsphere cavity
NASA Technical Reports Server (NTRS)
Iltchenko, Vladimir (Inventor); Maleki, Lute (Inventor); Yao, Steve (Inventor); Wu, Chi (Inventor)
2002-01-01
A system of coupling optical energy in a waveguide mode, into a resonator that operates in a whispering gallery mode. A first part of the operation uses a fiber in its waveguide mode to couple information into a resonator e.g. a microsphere. The fiber is cleaved at an angle .PHI. which causes total internal reflection within the fiber. The energy in the fiber then forms an evanescent field and a microsphere is placed in the area of the evanescent field. If the microsphere resonance is resonant with energy in the fiber, then the information in the fiber is effectively transferred to the microsphere.
Direct measurements of protein-stabilized gold nanoparticle interactions.
Eichmann, Shannon L; Bevan, Michael A
2010-09-21
We report integrated video and total internal reflection microscopy measurements of protein stabilized 110 nm Au nanoparticles confined in 280 nm gaps in physiological media. Measured potential energy profiles display quantitative agreement with Brownian dynamic simulations that include hydrodynamic interactions and camera exposure time and noise effects. Our results demonstrate agreement between measured nonspecific van der Waals and adsorbed protein interactions with theoretical potentials. Confined, lateral nanoparticle diffusivity measurements also display excellent agreement with predictions. These findings provide a basis to interrogate specific biomacromolecular interactions in similar experimental configurations and to design future improved measurement methods.
Optics of two-stage photovoltaic concentrators with dielectric second stages
NASA Astrophysics Data System (ADS)
Ning, Xiaohui; O'Gallagher, Joseph; Winston, Roland
1987-04-01
Two-stage photovoltaic concentrators with Fresnel lenses as primaries and dielectric totally internally reflecting nonimaging concentrators as secondaries are discussed. The general design principles of such two-stage systems are given. Their optical properties are studied and analyzed in detail using computer ray trace procedures. It is found that the two-stage concentrator offers not only a higher concentration or increased acceptance angle, but also a more uniform flux distribution on the photovoltaic cell than the point focusing Fresnel lens alone. Experimental measurements with a two-stage prototype module are presented and compared to the analytical predictions.
Structure and Dynamics of Interfaces: Drops and Films
NASA Technical Reports Server (NTRS)
Mann, J. Adin, Jr.; Mann, Elizabeth K.; Meyer, William V.; Neumann, A. Wilhelm; Tavana, Hossein
2015-01-01
We aim to acquire measurements of the structure and dynamics of certain liquid-fluid interfaces using an ensemble of techniques in collaboration: (1) Total internal reflection (TIR) Surface light scattering spectroscopy (SLSS), (2) Brewster angle microscopy (BAM), and (3) Drop-shape analysis. SLSS and BAM can be done on a shared interfacial footprint. Results using a 50-50 mixture of pentane-isohexane, which extends the range of NASA's Confined Vapor Bubble (CVB) experiment, yield surface tension results that differ from the expected Langmuir Fit. These results were confirmed using both the SLSS and drop-shape analysis approaches.
Pfeifer, Marcel; Ruf, Alexander; Fischer, Peer
2013-11-04
We record vibrational spectra with two indirect schemes that depend on the real part of the index of refraction: mid-infrared refractometry and photothermal spectroscopy. In the former, a quantum cascade laser (QCL) spot is imaged to determine the angles of total internal reflection, which yields the absorption line via a beam profile analysis. In the photothermal measurements, a tunable QCL excites vibrational resonances of a molecular monolayer, which heats the surrounding medium and changes its refractive index. This is observed with a probe laser in the visible. Sub-monolayer sensitivities are demonstrated.
Improved ATIR concentrator photovoltaic module
NASA Astrophysics Data System (ADS)
Adriani, Paul M.; Mao, Erwang
2013-09-01
Novel aggregated total internal reflection (ATIR) concentrator photovoltaic module design comprises 2-D shaped primary and secondary optics that effectively combine optical efficiency, low profile, convenient range of acceptance angles, reliability, and manufacturability. This novel optical design builds upon previous investigations by improving the shapes of primary and secondary optics to enable improved long-term reliability and manufacturability. This low profile, low concentration (5x to 10x) design fits well with one-axis trackers that are often used for flat plate crystalline silicon photovoltaic modules in large scale ground mount installations. Standard mounting points, materials, and procedures apply without changes from flat plate modules.
Panigrahi, Ritwik; Srivastava, Suneel K.
2015-01-01
In present work, spherical core (polystyrene, PS)/shell (polypyrrole, PPy) has been synthesized via in situ chemical oxidative copolymerization of pyrrole (Py) on the surface of sulfonated PS microsphere followed by the formation of hollow polypyrrole (HPPy) shell by dissolving PS inner core in THF. Thereafter, we first time established that such fabricated novel art of morphology acts as a conducting trap in absorbing electromagnetic (EM) wave by internal reflection. Further studies have been extended on the formation of its silver nanocomposites HPPy/Ag to strengthen our contention on this novel approach. Our investigations showed that electromagnetic interference (EMI) shielding efficiency (SE) of HPPy (34.5-6 dB) is significantly higher compared to PPy (20-5 dB) in the frequency range of 0.5-8 GHz due to the trapping of EM wave by internal reflection. We also observed that EMI shielding is further enhanced to 59–23 in 10 wt% Ag loaded HPPy/Ag-10. This is attributed to the simultaneous contribution of internal reflection as well as reflection from outer surface. Such high EMI shielding capacity using conducting polymers are rarely reported. PMID:25560384
NASA Astrophysics Data System (ADS)
König, Tobias A. F.; Ledin, Petr A.; Russell, Michael; Geldmeier, Jeffrey A.; Mahmoud, Mahmoud. A.; El-Sayed, Mostafa A.; Tsukruk, Vladimir V.
2015-03-01
We fabricated monolayer coatings of a silver nanocube aggregation to create a step-wise optical strip by applying different surface pressures during slow Langmuir-Blodgett deposition. The varying amount of randomly distributed nanocube aggregates with different surface coverages in gradient manner due to changes in surface pressure allows for continuous control of the polarization sensitive absorption of the incoming light over a broad optical spectrum. Optical characterization under total internal reflection conditions combined with electromagnetic simulations reveal that the broadband light absorption depends on the relative orientation of the nanoparticles to the polarization of the incoming light. By using computer simulations, we found that the electric field vector of the s-polarized light interacts with the different types of silver nanocube aggregations to excite different plasmonic resonances. The s-polarization shows dramatic changes of the plasmonic resonances at different angles of incidence (shift of 64 nm per 10° angle of incidence). With a low surface nanocube coverage (from 5% to 20%), we observed a polarization-selective high absorption of 80% (with an average 75%) of the incoming light over a broad optical range in the visible region from 400 nm to 700 nm. This large-area gradient material with location-dependent optical properties can be of particular interest for broadband light absorption, phase-sensitive sensors, and imaging.We fabricated monolayer coatings of a silver nanocube aggregation to create a step-wise optical strip by applying different surface pressures during slow Langmuir-Blodgett deposition. The varying amount of randomly distributed nanocube aggregates with different surface coverages in gradient manner due to changes in surface pressure allows for continuous control of the polarization sensitive absorption of the incoming light over a broad optical spectrum. Optical characterization under total internal reflection conditions combined with electromagnetic simulations reveal that the broadband light absorption depends on the relative orientation of the nanoparticles to the polarization of the incoming light. By using computer simulations, we found that the electric field vector of the s-polarized light interacts with the different types of silver nanocube aggregations to excite different plasmonic resonances. The s-polarization shows dramatic changes of the plasmonic resonances at different angles of incidence (shift of 64 nm per 10° angle of incidence). With a low surface nanocube coverage (from 5% to 20%), we observed a polarization-selective high absorption of 80% (with an average 75%) of the incoming light over a broad optical range in the visible region from 400 nm to 700 nm. This large-area gradient material with location-dependent optical properties can be of particular interest for broadband light absorption, phase-sensitive sensors, and imaging. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr06430e
Observing of tree trunks and other cylindrical objects using GPR
NASA Astrophysics Data System (ADS)
Jezova, Jana; Lambot, Sebastien
2016-04-01
Trees are a part of our everyday life, hence it is important to prevent their collapse to protect people and urban infrastructures. It is also important to characterize tree wood properties for usages in construction. In order to investigate internal parts of tree trunks non-invasively, ground-penetrating radar (GPR), or in this case, ultra-wideband microwave radar as a general tool, appears to be a very promising technology. Nevertheless, tree trunk tomography using microwave radar is a complicated task due to the circular shape of the trunk and the very complex (heterogeneous and anisotropic) internal structures of the trunk. Microwave sensing of tree trunks is also complicated due to the electromagnetic properties of living wood, which strongly depend on water content, density and temperature of wood. The objective of this study is to describe tree trunk radar cross sections including specific features originating from the particular circumferential data acquisition geometry. In that respect, three experiments were performed: (1) numerical simulations using a finite-difference time-domain software, namely, gprMax 2D, (2) measurements on a simplified laboratory trunk model including plastic and cardboard pipes, sand and air, and (3) measurements over a real tree trunk. The analysis was further deepened by considering: (1) common zero-offset reflection imaging, (2) imaging with a planar perfect electrical conductor (PEC) at the opposite side of the trunk, and (3) imaging with a PEC arc at the opposite side of the trunk. Furthermore, the shape of the reflection curve of a cylindrical target was analytically derived based on the straight-ray propagation approximation. Subsequently, the total internal reflection (TIR) phenomenon occurring in cylindrical objects was observed and analytically described. Both the straight-ray reflection curve and TIR were well observed on the simulated and laboratory radar data. A comparison between all experiments and radar configurations is presented. Future research will focus on the design of an adapted radar antenna for that application to optimize living tree trunk tomography. This research is funded by the Fonds de la Recherche Scientifique (FNRS, Belgium) and benefits from networking activities carried out within the EU COST Action TU1208 "Civil Engineering Applications of Ground Penetrating Radar".
Research on energy transmission calculation problem on laser detecting submarine
NASA Astrophysics Data System (ADS)
Fu, Qiang; Li, Yingchao; Zhang, Lizhong; Wang, Chao; An, Yan
2014-12-01
The laser detection and identification is based on the method of using laser as the source of signal to scan the surface of ocean. If the laser detection equipment finds out the target, it will immediately reflect the returning signal, and then through receiving and disposing the returning signal by the receiving system, to realize the function of detection and identification. Two mediums channels should be though in the process of laser detection transmission, which are the atmosphere and the seawater. The energy loss in the process of water transport, mainly considering the surface reflection and scattering attenuation and internal attenuation factors such as seawater. The energy consumption though atmospheric transmission, mainly considering the absorption of atmospheric and the attenuation causing by scattering, the energy consumption though seawater transmission, mainly considering the element such as surface reflection, the attenuation of scattering and internal attenuation of seawater. On the basis of the analysis and research, through the mode of establishment of atmospheric scattering, the model of sea surface reflection and the model of internal attenuation of seawater, determine the power dissipation of emitting lasers system, calculates the signal strength that reaches the receiver. Under certain conditions, the total attenuation of -98.92 dB by calculation, and put forward the related experiment scheme by the use of Atmospheric analog channel, seawater analog channel. In the experiment of the theory, we use the simulation pool of the atmosphere and the sea to replace the real environment where the laser detection system works in this kind of situation. To start with, we need to put the target in the simulating seawater pool of 10 meters large and then control the depth of the target in the sea level. We, putting the laser detection system in position where it is 2 kilometers far from one side, secondly use the equipment to aim at the target in some distance. Lastly, by launching and detecting the signal of returning wave, identify the effect of the image produced by the system.
Modular off-axis solar concentrator
Plesniak, Adam P; Hall, John C
2015-01-27
A solar concentrator including a housing defining a vertical axis and including a receiving wall connected to a reflecting wall to define an internal volume and an opening into the internal volume, wherein the reflecting wall defines at least one primary optical element, and wherein at least a portion of the reflecting wall includes a layer of reflective material, the housing further including a cover connected to the receiving wall and the reflecting wall to seal the opening, and at least one receiver mounted on the receiving wall such that a vertical axis of the receiver is disposed at a non-zero angle relative to the vertical axis of the housing, the receiver including at least one photovoltaic cell.
NASA Astrophysics Data System (ADS)
Saghaei, Hamed; Zahedi, Abdulhamid; Karimzadeh, Rouhollah; Parandin, Fariborz
2017-10-01
In this paper, a triangular two-dimensional photonic crystal (PhC) of As2Se3-chalcogenide rods in air is presented and its photonic band diagram is calculated by plane wave method. In this structure, an optical waveguide is obtained by creating a line defect (eliminating rods) in diagonal direction of PhC. Numerical simulations based on finite difference time domain method show that when self-collimated beams undergo total internal reflection at the PhC-air interface, a total reflection of 90° occurs for the output beams. We also demonstrate that by decreasing the radius of As2Se3-chalcogenide instead of eliminating a diagonal line, a two-channel optical splitter will be designed. In this case, incoming self-collimated beams can be divided into the reflected and transmitted beams with arbitrary power ratio by adjusting the value of their radii. Based on these results, we propose a four-channel optical splitter using four line defects. The power ratio among output channels can be controlled systematically by varying the radius of rods in the line defects. We also demonstrate that by launching two optical sources with the same intensity and 90° phase difference from both perpendicular faces of the PhC, two logic OR and XOR gates will be achieved at the output channels. These optical devices have some applications in photonic integrated circuits for controlling and steering (managing) the light as desired.
Cylindrical microlens with an internally reflecting surface and a method of fabrication
Beach, Raymond J.; Freitas, Barry L.
2004-03-23
A fast (high numerical aperture) cylindrical microlens, which includes an internally reflective surface, that functions to deviate the direction of the light that enters the lens from its original propagation direction is employed in optically conditioning laser diodes, laser diode arrays and laser diode bars.
A Cylindrical Microlens With An Internally Reflective Surface And A Method Of Fabrication
Beach, Raymond J.; Freitas, Barry L.
2005-09-27
A fast (high numerical aperture) cylindrical microlens, which includes an internally reflective surface, that functions to deviate the direction of the light that enters the lens from its original propagation direction is employed in optically conditioning laser diodes, laser diode arrays and laser diode bars.
Vermeulen, Lee C; Moles, Rebekah J; Collins, Jack C; Gray, Andy; Sheikh, Abdul Latif; Surugue, Jacqueline; Moss, Robert J; Ivey, Marianne F; Stevenson, James G; Takeda, Yasuo; Ranjit, Eurek; Chaar, Betty; Penm, Jonathan
2016-07-15
The processes used to revise the 2008 Basel Statements on the future of hospital pharmacy are summarized, and the revised statements are presented. The process for revising the Basel Statements followed an approach similar to that used during their initial development. The Hospital Pharmacy Section (HPS) of the International Pharmaceutical Federation (FIP) revised the 2008 FIP Basel Statements in four phases, including a survey of hospital pharmacists worldwide, an internal review, online forums, and a face-to-face "World Café" workshop in Bangkok, Thailand. The global survey on the initial Basel Statements included input from 334 respondents from 62 countries. The majority of respondents agreed that most of the initial Basel Statements were acceptable as written and did not require revision. In total, 11 statements were judged by more than 10% of respondents as needing revision or deletion. The FIP HPS executive committee used the survey results to develop 69 initial revised draft statements. After an online discussion with the international hospital pharmacy community, including individuals from 28 countries representing all six World Health Organization regions, a final set of draft statements was prepared for the live discussion involving participants from 20 countries. The final 65 revised Basel Statements were voted on and accepted. Systematic revision of the FIP Basel Statements resulted in an updated reflection of aspirational goals for the future of hospital pharmacy practice. While this revision reflects the development of new goals for hospital pharmacy practice, the core principles of the Basel Statements remain an essential foundation for the discipline. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Study on Hyperspectral Estimation Model of Total Nitrogen Content in Soil of Shaanxi Province
NASA Astrophysics Data System (ADS)
Liu, Jinbao; Dong, Zhenyu; Chen, Xi
2018-01-01
The development of hyperspectral remote sensing technology has been widely used in soil nutrient prediction. The soil is the representative soil type in Shaanxi Province. In this study, the soil total nitrogen content in Shaanxi soil was used as the research target, and the soil samples were measured by reflectance spectroscopy using ASD method. Pre-treatment, the first order differential, second order differential and reflectance logarithmic transformation of the reflected spectrum after pre-treatment, and the hyperspectral estimation model is established by using the least squares regression method and the principal component regression method. The results show that the correlation between the reflectance spectrum and the total nitrogen content of the soil is significantly improved. The correlation coefficient between the original reflectance and soil total nitrogen content is in the range of 350 ~ 2500nm. The correlation coefficient of soil total nitrogen content and first deviation of reflectance is more than 0.5 at 142nm, 1963nm, 2204nm and 2307nm, the second deviation has a significant positive correlation at 1114nm, 1470nm, 1967nm, 2372nm and 2402nm, respectively. After the reciprocal logarithmic transformation of the reflectance with the total nitrogen content of the correlation analysis found that the effect is not obvious. Rc2 = 0.7102, RMSEC = 0.0788; Rv2 = 0.8480, RMSEP = 0.0663, which can achieve the rapid prediction of the total nitrogen content in the region. The results show that the principal component regression model is the best.
Modeling the effect of reflection from metallic walls on spectroscopic measurements.
Zastrow, K-D; Keatings, S R; Marot, L; O'Mullane, M G; de Temmerman, G
2008-10-01
A modification of JET is presently being prepared to bring operational experience with ITER-like first wall (Be) and divertor (W) materials, geometry and plasma parameters. Reflectivity measurements of JET sample tiles have been performed and the data are used within a simplified model of the JET and ITER vessels to predict additional contributions to quantitative spectroscopic measurements. The most general method to characterize reflectivity is the bidirectional reflection distribution function (BRDF). For extended sources however, such as bremsstrahlung and edge emission of fuel and intrinsic impurities, the results obtained in the modeling are almost as accurate if the total reflectivity with ideal Lambertian angular dependence is used. This is in contrast to the experience in other communities, such as optical design, lighting design, or rendering who deal mostly with pointlike light sources. This result is so far based on a very limited set of measurements and will be reassessed when more detailed BRDF measurements of JET tiles have been made. If it is true it offers the possibility of in situ monitoring of the reflectivity of selected parts of the wall during exposure to plasma operation, while remeasurement of the BRDF is performed during interventions. For a closed vessel structure such as ITER, it is important to consider multiple reflections. This makes it more important to represent the whole of the vessel reasonably accurately in the model, which on the other hand is easier to achieve than for the more complex internal structure of JET. In both cases the dominant contribution is from the first reflection, and a detailed model of the areas intersected by lines of sight of diagnostic interest is required.
Metabolic fate of yolk fatty acids in the developing king penguin embryo.
Groscolas, René; Fréchard, Françoise; Decrock, Frédéric; Speake, Brian K
2003-10-01
This study examines the metabolic fate of total and individual yolk fatty acids (FA) during the embryonic development of the king penguin, a seabird characterized by prolonged incubation (53 days) and hatching (3 days) periods, and a high n-3/n-6 polyunsaturated FA ratio in the egg. Of the approximately 15 g of total FA initially present in the egg lipid, 87% was transferred to the embryo by the time of hatching, the remaining 13% being present in the internalized yolk sac of the chick. During the whole incubation, 83% of the transferred FA was oxidized for energy, with only 17% incorporated into embryo lipids. Prehatching (days 0-49), the fat stores (triacylglycerol) accounted for 58% of the total FA incorporated into embryo lipid. During hatching (days 49-53), 40% of the FA of the fat stores was mobilized, the mobilization of individual FA being nonselective. At hatch, 53% of the arachidonic acid (20:4n-6) of the initial yolk had been incorporated into embryo lipid compared with only 15% of the total FA and 17-24% of the various n-3 polyunsaturated FA. Similarly, only 32% of the yolk's initial content of 20:4n-6 was oxidized for energy during development compared with 72% of the total FA and 58-66% of the n-3 polyunsaturated FA. The high partitioning of yolk FA toward oxidization and the intense mobilization of fat store FA during hatching most likely reflect the high energy cost of the long incubation and hatching periods of the king penguin. The preferential partitioning of 20:4n-6 into the structural lipid of the embryo in the face of its low content in the yolk may reflect the important roles of this FA in tissue function.
Bridi, Raquel; Montenegro, Gloria; Nuñez-Quijada, Gabriel; Giordano, Ady; Fernanda Morán-Romero, Maria; Jara-Pezoa, Isaac; Speisky, Hernán; Atala, Elias; López-Alarcón, Camilo
2015-06-01
Propolis has been proposed as a polyphenolic-rich natural product potentially able to be used for human consumption or even for medicinal proposes. To guarantee a minimum phenolic and flavonoid content and as consequence of their related-biological activities, international requirements of propolis quality are commonly applied. In this work we assessed phenolic and flavonoid contents of propolis; the antioxidant capacity (toward peroxyl radicals and hypochlorous acid); the ability to generate nitric oxide (NO); and, finally the antimicrobial activity of 6 propolis samples from the VI region of Chile. Our results show that the total phenolic and flavonoid content of propolis samples are not always in agreement with their polyphenolic-associated in vitro activities. For example, P03 and P06 samples showed the lowest (25 ± 4 GAE/g propolis) and the highest (105 ± 3 GAE/g propolis) total phenolic content, respectively. This was in agreement with flavonoid content and their Oxygen Radical Absorbance Capacity (ORAC) activity. However, this dependence was not observed toward HOCl, NO release and antimicrobial activity. Based on our results, we consider that, in order to guarantee the antioxidant or antimicrobial in vitro effects, the international regulations of propolis quality should contemplate the convenience of incorporating other simple analytical test such as ORAC or antimicrobial tests. © 2015 Institute of Food Technologists®
Sex differences in the behavior of children with the 22q11 deletion syndrome
Sobin, Christina; Kiley-Brabeck, Karen; Monk, Samantha Hadley; Khuri, Jananne; Karayiorgou, Maria
2009-01-01
High rates of psychiatric impairment in adults with 22q11DS suggest that behavioral trajectories of children with 22q11DS may provide critical etiologic insights. Past findings that report DSM diagnoses are extremely variable; moreover sex differences in behavior have not yet been examined. Dimensional CBCL ratings from 82 children, including 51 with the 22q11DS and 31 control siblings were analyzed. Strikingly consistent with rates of psychiatric impairment among affected adults, 25% percent of children with 22q11DS had high CBCL scores for Total Impairment, and 20% had high CBCL Internalizing Scale scores. Males accounted for 90% of high Internalizing scores and 67% of high Total Impairment scores. Attention and Social Problems were ubiquitous; more affected males than females (23% vs. 4%) scored high on Thought Problems. With regard to CBCL/DSM overlap, 20% of affected males as compared with 0 affected females had one or more high CBCL ratings in the absence of a DSM diagnosis. Behaviors of children with 22q11DS are characterized by marked sex differences when rated dimensionally, with significantly more males experiencing Internalizing and Thought Problems. Categorical diagnoses do not reflect behavioral differences between male and female children with 22q11DS, and may miss significant behavior problems in 20% of affected males. PMID:19217670
Cost and quality implications of discrepancies between admitting and discharge diagnoses.
McNutt, Robert; Johnson, Tricia; Kane, Jason; Ackerman, Mariel; Odwazny, Richard; Bardhan, Jaydeep
2012-01-01
Presenting and discharge diagnoses of hospitalized patients may differ as a result of patient complexity, diagnostic dilemmas, or errors in clinical judgment at the time of primary assessment. When diagnoses at admission and discharge are not in agreement, this discrepancy may indicate more complex processes of care and resultant costs. It is unclear whether surrogate measures reflecting quality of care are impacted by discrepant diagnoses. To assess whether an association exists between admitting and discharge International Classification of Diseases, Ninth Revision (ICD-9) diagnosis codes and other quality markers including hospital length of stay, total cost of care, and 30-day readmission rate. This was a retrospective, cross-sectional analysis of general internal medicine patients aged 18 years and older. Diagnosis discrepancy was defined as a difference between the 3-digit ICD-9 diagnosis code at admission and the principal 3-digit ICD-9 diagnosis code at discharge. Sixty-eight percent of patients had a diagnosis discrepancy. Diagnosis discrepancy was associated with a 0.41-day increase in length of stay (P < .001), $663 increase in direct costs (P < .001), and a 1.55 times greater odds of readmission within 30 days (P < .001). Diagnosis discrepancy was associated with hospital quality outcome measures. This finding likely reflects variations in patients' diagnostic complexity.
Phased Array Noise Source Localization Measurements Made on a Williams International FJ44 Engine
NASA Technical Reports Server (NTRS)
Podboy, Gary G.; Horvath, Csaba
2010-01-01
A 48-microphone planar phased array system was used to acquire noise source localization data on a full-scale Williams International FJ44 turbofan engine. Data were acquired with the array at three different locations relative to the engine, two on the side and one in front of the engine. At the two side locations the planar microphone array was parallel to the engine centerline; at the front location the array was perpendicular to the engine centerline. At each of the three locations, data were acquired at eleven different engine operating conditions ranging from engine idle to maximum (take off) speed. Data obtained with the array off to the side of the engine were spatially filtered to separate the inlet and nozzle noise. Tones occurring in the inlet and nozzle spectra were traced to the low and high speed spools within the engine. The phased array data indicate that the Inflow Control Device (ICD) used during this test was not acoustically transparent; instead, some of the noise emanating from the inlet reflected off of the inlet lip of the ICD. This reflection is a source of error for far field noise measurements made during the test. The data also indicate that a total temperature rake in the inlet of the engine is a source of fan noise.
Morukov, B V; Popov, I N; Levin, G; Markin, A A; Zhuravleva, O A; Kuzichkin, D S
2013-01-01
In the 520-d chamber experiment within the international project Mars-500 blood samples of 6 male test-subjects of 28 to 39 years of age were analyzed for water-soluble antioxidants: total bilirubin and uric acid; in addition, total antioxidant capacity of blood plasma was determined. Maximal values of these parameters were associated with the most stressful periods of the experiment, i.e. adaptation to the life in isolation and confinement, simulation of the egress onto Martian surface, and change of the diet. On attainment of the homeostatic equilibrium the parameters stabilized on levels slightly lower relative to baseline (pre-isolation) values. Therefore, dynamics of the water-soluble antioxidants reflected adequately the homeostatic reactions to and compensation by organism of the effects of the 520-day life in isolation and confinement.
The international normalized ratio does not reflect bleeding risk in esophageal variceal hemorrhage.
Hshieh, Tammy T; Kaung, Aung; Hussain, Syed; Curry, Michael P; Sundaram, Vinay
2015-01-01
The international normalized ratio (INR) has not been validated as a predictor of bleeding risk in cirrhotics. The aim of this study was to determine whether elevation in the INR correlated with risk of esophageal variceal hemorrhage and whether correction of the INR prior to endoscopic therapy affects failure to control bleeding. Patient records were retrospectively reviewed from January 1, 2000 to December 31, 2010. Cases were cirrhotics admitted to the hospital due to bleeding esophageal varices. Controls were cirrhotics with a history of non-bleeding esophageal varices admitted with ascites or encephalopathy. All variceal bleeders were treated with octreotide, antibiotics, and band ligation. Failure to control bleeding was defined according to the Baveno V criteria. We analyzed 74 cases and 74 controls. The mean INR at presentation was lower in those with bleeding varices compared to non-bleeders (1.61 vs 1.74, P = 0.03). Those with bleeding varices had higher serum sodium (136.1 vs 133.8, P = 0.02), lower hemoglobin (9.59 vs 11.0, P < 0.001), and lower total bilirubin (2.47 vs 5.50, P < 0.001). Multivariable logistic regression showed total bilirubin to inversely correlate with bleeding (OR = 0.74). Bleeders received a mean of 1.14 units of fresh frozen plasma (FFP) prior to endoscopy (range 0-11 units). Of the 14 patients (20%) with failure to control bleeding, median INR (1.8 vs 1.5, P = 0.02) and median units of FFP transfused (2 vs 0, P = 0.01) were higher than those with hemostasis after the initial endoscopy. The INR reflects liver dysfunction, not bleeding risk. Correction of INR with FFP has little effect on hemostasis.
The International Normalized Ratio does not Reflect Bleeding Risk in Esophageal Variceal Hemorrhage
Hshieh, Tammy T.; Kaung, Aung; Hussain, Syed; Curry, Michael P.; Sundaram, Vinay
2015-01-01
Background/Aims: The international normalized ratio (INR) has not been validated as a predictor of bleeding risk in cirrhotics. The aim of this study was to determine whether elevation in the INR correlated with risk of esophageal variceal hemorrhage and whether correction of the INR prior to endoscopic therapy affects failure to control bleeding. Patients and Methods: Patient records were retrospectively reviewed from January 1, 2000 to December 31, 2010. Cases were cirrhotics admitted to the hospital due to bleeding esophageal varices. Controls were cirrhotics with a history of non-bleeding esophageal varices admitted with ascites or encephalopathy. All variceal bleeders were treated with octreotide, antibiotics, and band ligation. Failure to control bleeding was defined according to the Baveno V criteria. Results: We analyzed 74 cases and 74 controls. The mean INR at presentation was lower in those with bleeding varices compared to non-bleeders (1.61 vs 1.74, P = 0.03). Those with bleeding varices had higher serum sodium (136.1 vs 133.8, P = 0.02), lower hemoglobin (9.59 vs 11.0, P < 0.001), and lower total bilirubin (2.47 vs 5.50, P < 0.001). Multivariable logistic regression showed total bilirubin to inversely correlate with bleeding (OR = 0.74). Bleeders received a mean of 1.14 units of fresh frozen plasma (FFP) prior to endoscopy (range 0-11 units). Of the 14 patients (20%) with failure to control bleeding, median INR (1.8 vs 1.5, P = 0.02) and median units of FFP transfused (2 vs 0, P = 0.01) were higher than those with hemostasis after the initial endoscopy. Conclusions: The INR reflects liver dysfunction, not bleeding risk. Correction of INR with FFP has little effect on hemostasis. PMID:26228370
Shiga, Takuya; Shiraishi, Yasuyuki; Sano, Kyosuke; Taira, Yasunori; Tsuboko, Yusuke; Yamada, Akihiro; Miura, Hidekazu; Katahira, Shintaro; Akiyama, Masatoshi; Saiki, Yoshikatsu; Yambe, Tomoyuki
2016-03-01
Implantation of a total artificial heart (TAH) is one of the therapeutic options for the treatment of patients with end-stage biventricular heart failure. There is no report on the hemodynamics of the functional centrifugal-flow TAH with functional atrial contraction (fCFTAH). We evaluated the effects of pulsatile flow by atrial contraction in acute animal models. The goats received fCFTAH that we created from two centrifugal-flow ventricular assist devices. Some hemodynamic parameters maintained acceptable levels: heart rate 115.5 ± 26.3 bpm, aortic pressure 83.5 ± 10.1 mmHg, left atrial pressure 18.0 ± 5.9 mmHg, pulmonary pressure 28.5 ± 9.7 mmHg, right atrial pressure 13.6 ± 5.2 mmHg, pump flow 4.0 ± 1.1 L/min (left) 3.9 ± 1.1 L/min (right), and cardiac index 2.13 ± 0.14 L/min/m(2). fCFTAH with atrial contraction was able to maintain the TAH circulation by forming a pulsatile flow in acute animal experiments. Taking the left and right flow rate balance using the low internal pressure loss of the VAD pumps may be easier than by other pumps having considerable internal pressure loss. We showed that the remnant atrial contraction effected the flow rate change of the centrifugal pump, and the atrial contraction waves reflected the heart rate. These results indicate that remnant atria had the possibility to preserve autonomic function in fCFTAH. We may control fCFTAH by reflecting the autonomic function, which is estimated with the flow rate change of the centrifugal pump.
Xiong, Yan; Wang, Qing; Duan, Ming; Tan, Jun; Fang, Shenwen; Wu, Jiayi
2018-06-19
An interface research method based on total internal reflection induced evanescent wave (TIR-EW) is developed to monitor the adsorption behavior of azo dye at the silica-water interface. The monitoring system is constructed by employing silica optical fiber (SOF) as both charged substrate for dye adsorption and light transmission waveguide for evanescent wave production. According to the change of evanescent wave intensity and followed by Beer's law, the methylene blue (MB) adsorption behavior can be real-time monitored at the silica-water interface. Langmuir adsorption model and pseudo-first-order model are applied to obtain the related thermodynamic and kinetic data. The adsorption equilibrium constant ( K ads ) and adsorption free energy (Δ G) of MB at the silica-water interface are determined to be (3.3 ± 0.5) × 10 4 M -1 and -25.7 ± 1.7 kJ mol -1 . Meanwhile, this method is highlighted to isolate elementary processes of adsorption and desorption under steady-state conditions, and gives adsorption rate constant ( k a ) and desorption rate constant ( k d ) of 8585 ± 19.8 min -1 and 0.26 ± 0.0006 min -1 for 15 r/min flow rate. The surface interaction process is revealed and adsorption mechanism is proposed, indicating MB first adsorbed on Si-O - sites through electrostatic attraction and then on Si-OH sites through hydrogen bond with increasing MB concentrations. Our findings from this study provided molecular-level interpretation of azo dye adsorption at silica-water interface, and the results provide important insight into how MB adsorption can be controlled at the interface.
"Once when i was on call...," theory versus reality in training for professionalism.
Eggly, Susan; Brennan, Simone; Wiese-Rometsch, Wilhelmine
2005-04-01
To identify the degree to which interns' reported experiences with professional and unprofessional behavior converge and/or diverge with ideal professional behavior proposed by the physician community. Interns at Wayne State University's residency programs in internal medicine, family medicine, and transitional medicine responded to essay questions about their experience with professional and unprofessional behavior as part of a curriculum on professionalism. Responses were coded for whether they reflected each of the principles and responsibilities outlined in a major publication on physician professionalism. Content analysis included the frequencies with which the interns' essays reflected each principle or responsibility. Additionally, a thematic analysis revealed themes of professional behavior that emerged from the essays. Interns' experiences with professional and unprofessional behavior most frequently converged with ideal behavior proposed by the physician community in categories involving interpersonal interactions with patients. Interns infrequently reported experiences involving behavior related to systems or sociopolitical issues. Interns' essays reflect their concern with interpersonal interactions with patients, but they are either less exposed to or less interested in describing behavior regarding systems or sociopolitical issues. This may be due to their stage of training or to the emphasis placed on interpersonal rather than systems or sociopolitical issues during training. The authors recommend future proposals of ideal professional behavior be revised periodically to reflect current experiences of practicing physicians, trainees, other health care providers and patients. Greater educational emphasis should be placed on the systems and sociopolitical environment in which trainees practice.
Teaching and evaluating point of care learning with an Internet-based clinical-question portfolio.
Green, Michael L; Reddy, Siddharta G; Holmboe, Eric
2009-01-01
Diplomates in the American Board of Internal Medicine (ABIM) Maintenance of Certification (MOC) program satisfy the self-evaluation of medical knowledge requirement by completing open-book multiple-choice exams. However, this method remains unlikely to affect practice change and often covers content areas not relevant to diplomates' practices. We developed and evaluated an Internet-based point of care (POC) learning portfolio to serve as an alternative. Participants enter information about their clinical questions, including characteristics, information pursuit, application, and practice change. After documenting 20 questions, they reflect upon a summary report and write commitment-to-change statements about their learning strategies. They can link to help screens and medical information resources. We report on the beta test evaluation of the module, completed by 23 internists and 4 internal medicine residents. Participants found the instructions clear and navigated the module without difficulty. The majority preferred the POC portfolio to multiple-choice examinations, citing greater relevance to their practice, guidance in expanding their palette of information resources, opportunity to reflect on their learning needs, and "credit" for self-directed learning related to their patients. Participants entered a total of 543 clinical questions, of which 250 (46%) resulted in a planned practice change. After completing the module, 14 of 27 (52%) participants committed to at least 1 change in their POC learning strategies. Internists found the portfolio valuable, preferred it to multiple-choice examinations, often changed their practice after pursuing clinical questions, and productively reflected on their learning strategies. The ABIM will offer this portfolio as an elective option in MOC.
Olsson, Jan-Eric; Wallentin, Fan Yang; Toth-Pal, Eva; Ekblad, Solvig; Bertilson, Bo Christer
2017-07-10
To determine the internal consistency and the underlying components of our translated and adapted Swedish version of the General Medical Council's multisource feedback questionnaires (GMC questionnaires) for physicians and to confirm which aspects of good medical practice the latent variable structure reflected. From October 2015 to March 2016, residents in family medicine in Sweden were invited to participate in the study and to use the Swedish version to perform self-evaluations and acquire feedback from both their patients and colleagues. The validation focused on internal consistency and construct validity. Main outcome measures were Cronbach's alpha coefficients, Principal Component Analysis, and Confirmatory Factor Analysis indices. A total of 752 completed questionnaires from patients, colleagues, and residents were analysed. Of these, 213 comprised resident self-evaluations, 336 were feedback from residents' patients, and 203 were feedback from residents' colleagues. Cronbach's alpha coefficients of the scores were 0.88 from patients, 0.93 from colleagues, and 0.84 in the self-evaluations. The Confirmatory Factor Analysis validated two models that fit the data reasonably well and reflected important aspects of good medical practice. The first model had two latent factors for patient-related items concerning empathy and consultation management, and the second model had five latent factors for colleague-related items, including knowledge and skills, attitude and approach, reflection and development, teaching, and trust. The current Swedish version seems to be a reliable and valid tool for formative assessment for resident physicians and their supervisors. This needs to be verified in larger samples.
Wallentin, Fan Yang; Toth-Pal, Eva; Ekblad, Solvig; Bertilson, Bo Christer
2017-01-01
Objectives To determine the internal consistency and the underlying components of our translated and adapted Swedish version of the General Medical Council's multisource feedback questionnaires (GMC questionnaires) for physicians and to confirm which aspects of good medical practice the latent variable structure reflected. Methods From October 2015 to March 2016, residents in family medicine in Sweden were invited to participate in the study and to use the Swedish version to perform self-evaluations and acquire feedback from both their patients and colleagues. The validation focused on internal consistency and construct validity. Main outcome measures were Cronbach’s alpha coefficients, Principal Component Analysis, and Confirmatory Factor Analysis indices. Results A total of 752 completed questionnaires from patients, colleagues, and residents were analysed. Of these, 213 comprised resident self-evaluations, 336 were feedback from residents’ patients, and 203 were feedback from residents’ colleagues. Cronbach’s alpha coefficients of the scores were 0.88 from patients, 0.93 from colleagues, and 0.84 in the self-evaluations. The Confirmatory Factor Analysis validated two models that fit the data reasonably well and reflected important aspects of good medical practice. The first model had two latent factors for patient-related items concerning empathy and consultation management, and the second model had five latent factors for colleague-related items, including knowledge and skills, attitude and approach, reflection and development, teaching, and trust. Conclusions The current Swedish version seems to be a reliable and valid tool for formative assessment for resident physicians and their supervisors. This needs to be verified in larger samples. PMID:28704204
ERIC Educational Resources Information Center
Bitz, Michael; Emejulu, Obiajulu
2016-01-01
This article is an international reflection on literacy, creativity, and student engagement. The authors collaborated to help Nigerian youths and their teachers develop, design, and share original comic books. By leveraging student engagement for literacy learning, the authors highlighted the crucial role of creativity in the classroom. The…
Students' Quality of Mathematical Discussion and Their Self-Determination in Mathematics
ERIC Educational Resources Information Center
Kosko, Karl W.; Wilkins, Jesse L. M.
2012-01-01
Mathematical discussion allows for students to reflect upon math concepts and understand such concepts at a deeper level. This process of reflection requires a certain amount of internalization on the part of the student. This internalization is facilitated by meeting the needs of autonomy, competence, and relatedness as advocated by…
ERIC Educational Resources Information Center
Saa'd AlDin, Kawther
2014-01-01
In 2010, the International Baccalaureate (IB) Organization mandated that all its schools, including Diploma (DP) schools, adhere to the collaborative planning and reflection requirements, which emphasized the importance of integrating its theory of knowledge (TOK) core component into all disciplines. Many schools officials and educations in Amman…
ERIC Educational Resources Information Center
Clark, J. Spencer; Brown, James Scott; Jandildinov, Medet
2016-01-01
The concepts of reflection and reflective practice have become the core of many teacher education programmes, with critical reflection as the goal for many teacher educators. This study examined the use of a videoconference discussion in an instructional methodology course as a means to enrich the process of reflection and encourage critical…
Where is the "meta" in animal metacognition?
Kornell, Nate
2014-05-01
Apes, dolphins, and some monkeys seem to have metacognitive abilities: They can accurately evaluate the likelihood that their response in cognitive task was (or will be) correct. These certainty judgments are seen as significant because they imply that animals can evaluate internal cognitive states, which may entail meaningful self-reflection. But little research has investigated what is being reflected upon: Researchers have assumed that when animals make metacognitive judgments they evaluate internal memory strength. Yet decades of research have demonstrated that humans cannot directly evaluate internal memory strength. Instead, they make certainty judgments by drawing inferences from cues they can evaluate, such as familiarity and ease of processing. It seems likely that animals do the same, but this hypothesis has not been tested. I suggest two strategies for investigating the internal cues that underlie animal metacognitive judgments. It is possible that animals, like humans, are capable of making certainty judgments based on internal cues without awareness or meaningful self-reflection. ©2014 APA, all rights reserved.
Surface plasmon coupled chemiluminescence during adsorption of oxygen on magnesium surfaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hagemann, Ulrich; Nienhaus, Hermann, E-mail: hermann.nienhaus@uni-due.de
The dissociative adsorption of oxygen molecules on magnesium surfaces represents a non-adiabatic reaction exhibiting exoelectron emission, chemicurrent generation, and weak chemiluminescence. Using thin film Mg/Ag/p-Si(111) Schottky diodes with 1 nm Mg on a 10-60 nm thick Ag layer as 2π-photodetectors, the chemiluminescence is internally detected with a much larger efficiency than external methods. The chemically induced photoyield shows a maximum for a Ag film thickness of 45 nm. The enhancement is explained by surface plasmon coupled chemiluminescence, i.e., surface plasmon polaritons are effectively excited in the Ag layer by the oxidation reaction and decay radiatively leading to the observed photocurrent.more » Model calculations of the maximum absorption in attenuated total reflection geometry support the interpretation. The study demonstrates the extreme sensitivity and the practical usage of internal detection schemes for investigating surface chemiluminescence.« less
Reactive Collisions in Crossed Molecular Beams
DOE R&D Accomplishments Database
Herschbach, D. R.
1962-02-01
The distribution of velocity vectors of reaction products is discussed with emphasis on the restrictions imposed by the conservation laws. The recoil velocity that carries the products away from the center of mass shows how the energy of reaction is divided between internal excitation and translation. Similarly, the angular distributions, as viewed from the center of mass, reflect the partitioning of the total angular momentum between angular momenta of individual molecules and orbital angular momentum associated with their relative motion. Crossed-beam studies of several reactions of the type M + RI yields R + MI are described, where M = K, Rb, Cs, and R = CH{sub 3}, C{sub 3}H{sub 5}, etc. The results show that most of the energy of reaction goes into internal excitation of the products and that the angular distribution is quite anisotropic, with most of the MI recoiling backward (and R forward) with respect to the incoming K beam. (auth)
Robust sensor for turbidity measurement from light scattering and absorbing liquids.
Kontturi, Ville; Turunen, Petri; Uozumi, Jun; Peiponen, Kai-Erik
2009-12-01
Internationally standardized turbidity measurements for probing solid particles in liquid are problematic in the case of simultaneous light scattering and absorption. A method and a sensor to determine the turbidity in the presence of light absorption are presented. The developed sensor makes use of the total internal reflection of a laser beam at the liquid-prism interface, and the turbidity is assessed using the concept of laser speckle pattern. Using average filtering in speckle data analyzing the observed dynamic speckle pattern, which is due to light scattering from particles and the static speckle due to stray light of the sensor, can be separated from each other. Good correlation between the standard deviation of dynamic speckle and turbidity value for nonabsorbing and for absorbing liquids was observed. The sensor is suggested, for instance, for the measurement of ill-behaved as well as small-volume turbid liquids in both medicine and process industry.
Takase, Miyuki; Imai, Takiko; Uemura, Chizuru
2016-06-01
This paper examines the psychometric properties of the Learning Experience Scale. A survey method was used to collect data from a total of 502 nurses. Data were analyzed by factor analysis and the known-groups technique to examine the construct validity of the scale. In addition, internal consistency was evaluated by Cronbach's alpha, and stability was examined by test-retest correlation. Factor analysis showed that the Learning Experience Scale consisted of five factors: learning from practice, others, training, feedback, and reflection. The scale also had the power to discriminate between nurses with high and low levels of nursing competence. The internal consistency and the stability of the scale were also acceptable. The Learning Experience Scale is a valid and reliable instrument, and helps organizations to effectively design learning interventions for nurses. © 2015 Wiley Publishing Asia Pty Ltd.
NASA Technical Reports Server (NTRS)
Khodadad, Christina L.; Birmele, Michele N.; Roman, Monsi; Hummerick, Mary E.; Smith, David J.; Wheeler, Raymond M.
2015-01-01
Previous research has shown that potentially destructive microorganisms and human pathogens have been detected on the International Space Station (ISS). The likelihood of introducing new microorganisms occurs with every exchange of crew or addition of equipment or supplies. Microorganisms introduced to the ISS are readily transferred between crew and subsystems (i.e. ECLSS, environmental control and life support systems). Current microbial characterization methods require enrichment of microorganisms and at least a 48-hour incubation time. This increases the microbial load while detecting only a limited number of the total microorganisms. The culture based method detects approximately 1-10% of the total organisms present and provides no identification. To identify and enumerate ISS microbes requires that samples be returned to Earth for complete analysis. Therefore, a more expedient, low-cost, in-flight method of microbial detection, identification, and enumeration is warranted. The RAZOR EX, a ruggedized, commercial off the shelf, real-time PCR field instrument was tested for its ability to detect microorganisms at low concentrations within one hour. Escherichia coli, Salmonella enterica Typhimurium, and Pseudomonas aeruginosa were detected at low levels using real-time DNA amplification. Total heterotrophic counts could also be detected using a 16S gene marker that can identify up to 98% of all bacteria. To reflect viable cells found in the samples, RNA was also detectable using a modified, single-step reverse transcription reaction.
Frequency selective reflection and transmission at a layer composed of a periodic dielectric
NASA Technical Reports Server (NTRS)
Bertoni, Henry L.; Cheo, Li-Hsiang S.; Tamir, Theodor
1987-01-01
The feasibility of using a periodic dielectric layer, composed of alternating bars having dielectric constants epsilon sub 1 and epsilon sub 2, as a frequency selective subreflector in order to permit feed separation in large aperture reflecting antenna systems was examined. For oblique incidence, it is found that total transmission and total reflection can be obtained at different frequencies for proper choices of epsilon sub 1, epsilon 2, and the geometric parameters. The frequencies of total reflection and transmission can be estimated from wave phenomena occurring in a layer of uniform dielectric constant equal to the average for the periodic layers. About some of the frequencies of total transmission, the bandwidth for 90% transmission is found to be 40%. However, the bandwidth for 90% reflection is always found to be much narrower; the greatest value found being 2.5%.
NASA Astrophysics Data System (ADS)
Kao, I.-Ling; Ku, Chun-Neng; Chen, Yi-Ping; Lin, Ding-Zheng
2012-09-01
We proposed an internal nanostructure with a high reflective index planarization layer to solve the optical loss due to the reflective index mismatch between ITO and glass substrate. In our experiments, we found the electrical property of OLED device was significantly influenced by the internal nanostructures without planarization layer. Moreover, the internal extraction structure (IES) is not necessarily beneficial for light extraction. Therefore, we proposed a new substrate combine both internal and external extraction structure (EES) to extract trapping light. We successfully developed a high refractive index (N 1.7) planarization material with flat surface (RMS roughness < 2 nm), and improved about 70% device efficiency compared to traditional glass substrate.
Reflections on Building "Glocal" Competence among Pre-Service and In-Service Teachers
ERIC Educational Resources Information Center
Gichiru, Wangari
2016-01-01
The purpose of this paper is to critically reflect on two graduate international comparative education courses I taught at a mid-sized public university. Using a variety of readings and multimedia focusing on voices of international educators telling their own stories of struggle for a democratic education, these courses represent my effort to…
ERIC Educational Resources Information Center
King, Virginia; Clouder, Lynn; Deane, Mary; Deepwell, Frances; Ganobcsik-Williams, Lisa
2007-01-01
Through reflection on the First International iPED Conference 2006, and its overarching theme of "Pedagogical Research and Academic Identities", this paper considers the achievement of the wider aims of the conference, which were to facilitate dialogue between researchers in order to explore the conference themes collaboratively, and to…
Symbolic Uses of Evaluation in the International Aid Sector: Arguments for Critical Reflection
ERIC Educational Resources Information Center
McNulty, James
2012-01-01
Significant progress has been made in recent years to improve the quality of the evaluation of international aid. Increasingly, this includes an interest in improving the way evaluations are used to improve policies and programmes. However, the prevalence of symbolic use--a phenomenon that is often mentioned but rarely studied--reflects an…
Solar module having reflector between cells
Kardauskas, Michael J.
1999-01-01
A photovoltaic module comprising an array of electrically interconnected photovoltaic cells disposed in a planar and mutually spaced relationship between a light-transparent front cover member in sheet form and a back sheet structure is provided with a novel light-reflecting means disposed between adjacent cells for reflecting light falling in the areas between cells back toward said transparent cover member for further internal reflection onto the solar cells. The light-reflecting comprises a flexible plastic film that has been embossed so as to have a plurality of small V-shaped grooves in its front surface, and a thin light-reflecting coating on said front surface, the portions of said coating along the sides of said grooves forming light-reflecting facets, said grooves being formed so that said facets will reflect light impinging thereon back into said transparent cover sheet with an angle of incidence greater than the critical angle, whereby substantially all of the reflected light will be internally reflected from said cover sheet back to said solar modules, thereby increasing the current output of the module.
Experimental demonstration of the vertical spin existence in evanescent waves
NASA Astrophysics Data System (ADS)
Maksimyak, P. P.; Maksimyak, A. P.; Ivanskyi, D. I.
2018-01-01
Physical existence of the recently discovered vertical spin arising in an evanescent light wave due to the total internal reflection of a linearly polarized probing beam with azimuthal angle 45° is experimentally verified. Mechanical action, caused by optical force, associated with the extraordinary transverse component of the spin in evanescent wave is demonstrated. The motion of a birefringent plate in a direction controlled by simultaneous action of the canonical momentum and the transversal spin momentum is observed. The contribution of the canonical and spin momenta in determination of the trajectory of the resulting motion occur commensurable under exceptionally delicately determined experimental conditions.
2008-01-01
BMI and higher body fat among Army recruits, or it could reflect changes in occupational exposures in the Army. For instance, some occupational...Intervertebral Disc w/o Myelopathy 613 2.45% 733.1 Pathological Fracture 530 2.11% * Percents are given out of the total number of musculoskeletal...Atherosclerosis 228 17.97% 733.1 Pathological Fracture 121 9.54% 443.0 Raynaud’s Syndrome 75 5.91% 729.5 Pain in Limb 74 5.83% 733.9 Other and Unspecified
Parasitic oscillation suppression in solid state lasers using absorbing thin films
Zapata, L.E.
1994-08-02
A thin absorbing film is bonded onto at least certain surfaces of a solid state laser gain medium. An absorbing metal-dielectric multilayer film is optimized for a broad range of incidence angles, and is resistant to the corrosive/erosive effects of a coolant such as water, used in the forced convection cooling of the film. Parasitic oscillations hamper the operation of solid state lasers by causing the decay of stored energy to amplified rays trapped within the gain medium by total and partial internal reflections off the gain medium facets. Zigzag lasers intended for high average power operation require the ASE absorber. 16 figs.
Wigner functions for evanescent waves.
Petruccelli, Jonathan C; Tian, Lei; Oh, Se Baek; Barbastathis, George
2012-09-01
We propose phase space distributions, based on an extension of the Wigner distribution function, to describe fields of any state of coherence that contain evanescent components emitted into a half-space. The evanescent components of the field are described in an optical phase space of spatial position and complex-valued angle. Behavior of these distributions upon propagation is also considered, where the rapid decay of the evanescent components is associated with the exponential decay of the associated phase space distributions. To demonstrate the structure and behavior of these distributions, we consider the fields generated from total internal reflection of a Gaussian Schell-model beam at a planar interface.
Fingertip-shaped optical tactile sensor for robotic applications
NASA Technical Reports Server (NTRS)
Begej, Stefan
1988-01-01
Progress is described regarding the development of a high-density, fiber-optic, fingertip-shaped tactile sensor specifically designed for application to dexterous robotics. The sensor operates on optical principles involving the frustration of total internal reflection at a waveguide/elastomer interface and generates a grey-scale tactile image that represents the normal forces of contact. The sensor contains 256 taxels (sensing sites) distributed in a dual-density pattern that includes a tactile fovea near the tip which measures 13 mm x 13 mm and contains 169 taxels. The details regarding the design and construction of this tactile sensor are presented, in addition to photographs of tactile imprints.
Maximum-performance fiber-optic irradiation with nonimaging designs.
Fang, Y; Feuermann, D; Gordon, J M
1997-10-01
A range of practical nonimaging designs for optical fiber applications is presented. Rays emerging from a fiber over a restricted angular range (small numerical aperture) are needed to illuminate a small near-field detector at maximum radiative efficiency. These designs range from pure reflector (all-mirror), to pure dielectric (refractive and based on total internal reflection) to lens-mirror combinations. Sample designs are shown for a specific infrared fiber-optic irradiation problem of practical interest. Optical performance is checked with computer three-dimensional ray tracing. Compared with conventional imaging solutions, nonimaging units offer considerable practical advantages in compactness and ease of alignment as well as noticeably superior radiative efficiency.
Silica aerogel core waveguide.
Grogan, M D W; Leon-Saval, S G; England, R; Birks, T A
2010-10-11
We have selectively filled the core of hollow photonic crystal fibre with silica aerogel. Light is guided in the aerogel core, with a measured attenuation of 0.2 dB/cm at 1540 nm comparable to that of bulk aerogel. The structure guides light by different mechanisms depending on the wavelength. At long wavelengths the effective index of the microstructured cladding is below the aerogel index of 1.045 and guidance is by total internal reflection. At short wavelengths, where the effective cladding index exceeds 1.045, a photonic bandgap can guide the light instead. There is a small region of crossover, where both index- and bandgap-guided modes were simultaneously observed.
Optical sensing: recognition elements and devices
NASA Astrophysics Data System (ADS)
Gauglitz, Guenter G.
2012-09-01
The requirements in chemical and biochemical sensing with respect to recognition elements, avoiding non-specific interactions, and high loading of the surface for detection of low concentrations as well as optimized detection systems are discussed. Among the many detection principles the optical techniques are classified. Methods using labeled compounds like Total Internal Reflection Fluorescence (TIRF) and direct optical methods like micro reflectometry or refractometry are discussed in comparison. Reflectometric Interference Spectroscopy (RIfS) is presented as a robust simple method for biosensing. As applications, trace analysis of endocrine disruptors in water, hormones in food, detection of viruses and bacteria in food and clinical diagnostics are discussed.
Microscopy basics and the study of actin-actin-binding protein interactions.
Thomasson, Maggie S; Macnaughtan, Megan A
2013-12-15
Actin is a multifunctional eukaryotic protein with a globular monomer form that polymerizes into a thin, linear microfilament in cells. Through interactions with various actin-binding proteins (ABPs), actin plays an active role in many cellular processes, such as cell motility and structure. Microscopy techniques are powerful tools for determining the role and mechanism of actin-ABP interactions in these processes. In this article, we describe the basic concepts of fluorescent speckle microscopy, total internal reflection fluorescence microscopy, atomic force microscopy, and cryoelectron microscopy and review recent studies that utilize these techniques to visualize the binding of actin with ABPs. Copyright © 2013 Elsevier Inc. All rights reserved.
Parasitic oscillation suppression in solid state lasers using absorbing thin films
Zapata, Luis E.
1994-01-01
A thin absorbing film is bonded onto at least certain surfaces of a solid state laser gain medium. An absorbing metal-dielectric multilayer film is optimized for a broad range of incidence angles, and is resistant to the corrosive/erosive effects of a coolant such as water, used in the forced convection cooling of the film. Parasitic oscillations hamper the operation of solid state lasers by causing the decay of stored energy to amplified rays trapped within the gain medium by total and partial internal reflections off the gain medium facets. Zigzag lasers intended for high average power operation require the ASE absorber.
Numerical simulation of eigenmodes of ring and race-track optical microresonators
NASA Astrophysics Data System (ADS)
Raskhodchikov, A. V.; Raskhodchikov, D. V.; Scherbak, S. A.; Lipovskii, A. A.
2017-11-01
We have performed a numerical study of whispering gallery modes of ring and race-track optical microresonators. Mode excitation was considered and their spectra and electromagnetic field distributions were calculated via numerical solution of the Helmholtz equation. We pay additional attention to features of eigenmodes in race-tracks in contrast with ring resonators. Particularly, we demonstrate that modes in race-tracks are not “classic” WGM in terms of total internal reflection from a single boundary, and an inner boundary is essential for their formation. The dependence of effective refractive index of race-tracks modes on the resonator width is shown.
Rainwater analysis by synchrotron radiation-total reflection X-ray fluorescence
NASA Astrophysics Data System (ADS)
López, María L.; Ceppi, Sergio A.; Asar, María L.; Bürgesser, Rodrigo E.; Ávila, Eldo E.
2015-11-01
Total reflection X-ray fluorescence analysis excited with synchrotron radiation was used to quantify the elemental concentration of rainwater in Córdoba, Argentina. Standard solutions with gallium as internal standard were prepared for the calibration curves. Rainwater samples of 5 μl were added to an acrylic reflector, allowed to dry, and analyzed for 200 s measuring time. The elemental concentrations of As, Ca, Co, Cr, Cu, Fe, K, Mn, Ni, Pb, S, Sr, V, and Zn were determined. The electrical conductivity, pH, and elemental concentrations were compared to data previously reported for the soluble fraction of rainwater at different sites. A factor analysis was performed in order to determine the sources that contributed to the elemental concentration in rainwater. Anthropogenic sources were identified as traffic pollution, vehicular emissions, and metallurgical factories. The quality of rainwater was analyzed by comparing the concentrations of all the elements in rainwater samples with the WHO guideline values for drinking water. The results show the need to control the atmospheric emissions in order to preserve the quality of rainwater. SR-TXRF analysis of chemical composition of rainwater in Córdoba represents the very first contribution in the region to the knowledge of the concentration of trace metals in the soluble fraction of rainwater. These data are scarce, especially in the Southern Hemisphere.
Lebanese household carbon footprint: Measurements, analysis and challenges
NASA Astrophysics Data System (ADS)
Nasr, Rawad; Tall, Ibrahim; Nachabe, Nour; Chaaban, Farid
2016-07-01
The main purpose of this paper is to estimate the carbon footprint of a typical Lebanese household, and compare the results with international standards and trends. The estimation of this footprint will reflect the impact of the daily Lebanese household activities on the environment in terms of carbon dioxide emissions. The method used in estimating the carbon emissions is based on gathering the primary footprints from various household activities. Another proposed method that provides more accurate results is the estimation of emissions based on secondary footprint, which reflects the total emissions not only from the regular activities but also from a lifecycle perspective. Practical and feasible solutions were proposed to help reduce the amount of C02 emissions per household. This would lead to a better air quality, money savings, greenhouse gases emissions reduction and would ensure the sustainability and prosperity of future generations. A detailed survey was conducted in which the questions were focused mainly on energy, food, and transportation issues. The fourteen questions were addressed to one hundred families in different Lebanese regions coming from different social and economic backgrounds. This diversity would constitute a reflective sample of the actual Lebanese society, allowing us to extrapolate the gathered results on a national level.
Light funnel concentrator panel for solar power
NASA Technical Reports Server (NTRS)
1987-01-01
The solar concentrator design concept provides a theoretical concentration efficiency of 96 percent with power-to-weight ratios as high as 50 W/kg. Further, it eliminates the need for fragile reflective coatings and is very tolerant to pointing inaccuracies. The concept differs from conventional reflective mirrors and lens design in that is uses the principle of total internal reflection in order to funnel incident sunlight into a concentrator photovoltaic cell. The feasibility of the light funnel concentrator concept was determined through a balanced approach of analysis, development, and fabrication of prototypes, and testing of components. A three-dimensional optical model of the light funnel concentrator and photovoltaic cell was developed in order to assess the ultimate performance of such systems. In addition, a thermal and structural analysis of a typical unit was made. Techniques of fabricating the light funnel cones, optically coupling them to GaAs concentrator cells, bonding the funnels to GaAs cells, making electrical interconnects, and bonding substrates was explored and a prototype light funnel concentrator unit was fabricated and tested. Testing of the system included measurements of optical concentrating efficiency, optical concentrator to cell coupling efficiency, and electrical efficiency.
Narrow groove plasmonic nano-gratings for surface plasmon resonance sensing
Dhawan, Anuj; Canva, Michael; Vo-Dinh, Tuan
2011-01-01
We present a novel surface plasmon resonance (SPR) configuration based on narrow groove (sub-15 nm) plasmonic nano-gratings such that normally incident radiation can be coupled into surface plasmons without the use of prism-coupling based total internal reflection, as in the classical Kretschmann configuration. This eliminates the angular dependence requirements of SPR-based sensing and allows development of robust miniaturized SPR sensors. Simulations based on Rigorous Coupled Wave Analysis (RCWA) were carried out to numerically calculate the reflectance - from different gold and silver nano-grating structures - as a function of the localized refractive index of the media around the SPR nano-gratings as well as the incident radiation wavelength and angle of incidence. Our calculations indicate substantially higher differential reflectance signals, on localized change of refractive index in the narrow groove plasmonic gratings, as compared to those obtained from conventional SPR-based sensing systems. Furthermore, these calculations allow determination of the optimal nano-grating geometric parameters - i. e. nanoline periodicity, spacing between the nanolines, as well as the height of the nanolines in the nano-grating - for highest sensitivity to localized change of refractive index, as would occur due to binding of a biomolecule target to a functionalized nano-grating surface. PMID:21263620
Nanoscale cellular imaging with scanning angle interference microscopy.
DuFort, Christopher; Paszek, Matthew
2014-01-01
Fluorescence microscopy is among the most widely utilized tools in cell and molecular biology due to its ability to noninvasively obtain time-resolved images of live cells with molecule-specific contrast. In this chapter, we describe a simple high-resolution technique, scanning angle interference microscopy (SAIM), for the imaging and localization of fluorescent molecules with nanometer precision along the optical axis. In SAIM, samples above a reflective surface are sequentially scanned with an excitation laser at varying angles of incidence. Interference patterns generated between the incident and reflected lights result in an emission intensity that depends on the height of a fluorophore above the silicon surface and the angle of the incident radiation. The measured fluorescence intensities are then fit to an optical model to localize the labeled molecules along the z-axis with 5-10 nm precision and diffraction-limited lateral resolution. SAIM is easily implemented on widely available commercial total internal reflection fluorescence microscopes, offering potential for widespread use in cell biology. Here, we describe the setup of SAIM and its application for imaging cellular structures near (<1 μm) the sample substrate. © 2014 Elsevier Inc. All rights reserved.
Reflectively Coupled Waveguide Photodetector for High Speed Optical Interconnection
Hsu*, Shih-Hsiang
2010-01-01
To fully utilize GaAs high drift mobility, techniques to monolithically integrate In0.53Ga0.47As p-i-n photodetectors with GaAs based optical waveguides using total internal reflection coupling are reviewed. Metal coplanar waveguides, deposited on top of the polyimide layer for the photodetector’s planarization and passivation, were then uniquely connected as a bridge between the photonics and electronics to illustrate the high-speed monitoring function. The photodetectors were efficiently implemented and imposed on the echelle grating circle for wavelength division multiplexing monitoring. In optical filtering performance, the monolithically integrated photodetector channel spacing was 2 nm over the 1,520–1,550 nm wavelength range and the pass band was 1 nm at the −1 dB level. For high-speed applications the full-width half-maximum of the temporal response and 3-dB bandwidth for the reflectively coupled waveguide photodetectors were demonstrated to be 30 ps and 11 GHz, respectively. The bit error rate performance of this integrated photodetector at 10 Gbit/s with 27-1 long pseudo-random bit sequence non-return to zero input data also showed error-free operation. PMID:22163502
Mechanical modulation method for ultrasensitive phase measurements in photonics biosensing.
Patskovsky, S; Maisonneuve, M; Meunier, M; Kabashin, A V
2008-12-22
A novel polarimetry methodology for phase-sensitive measurements in single reflection geometry is proposed for applications in optical transduction-based biological sensing. The methodology uses altering step-like chopper-based mechanical phase modulation for orthogonal s- and p- polarizations of light reflected from the sensing interface and the extraction of phase information at different harmonics of the modulation. We show that even under a relatively simple experimental arrangement, the methodology provides the resolution of phase measurements as low as 0.007 deg. We also examine the proposed approach using Total Internal Reflection (TIR) and Surface Plasmon Resonance (SPR) geometries. For TIR geometry, the response appears to be strongly dependent on the prism material with the best values for high refractive index Si. The detection limit for Si-based TIR is estimated as 10(-5) in terms Refractive Index Units (RIU) change. SPR geometry offers much stronger phase response due to a much sharper phase characteristics. With the detection limit of 3.2*10(-7) RIU, the proposed methodology provides one of best sensitivities for phase-sensitive SPR devices. Advantages of the proposed method include high sensitivity, simplicity of experimental setup and noise immunity as a result of a high stability modulation.
Yu, Weiyu; Wardrop, Nicola A.; Bain, Robert E. S.; Lin, Yanzhao; Zhang, Ce; Wright, Jim A.
2016-01-01
Following the recent expiry of the United Nations’ 2015 Millennium Development Goals (MDGs), new international development agenda covering 2030 water, sanitation and hygiene (WASH) targets have been proposed, which imply new demands on data sources for monitoring relevant progress. This study evaluates drinking-water and sanitation classification systems from national census questionnaire content, based upon the most recent international policy changes, to examine national population census’s ability to capture drinking-water and sanitation availability, safety, accessibility, and sustainability. In total, 247 censuses from 83 low income and lower-middle income countries were assessed using a scoring system, intended to assess harmonised water supply and sanitation classification systems for each census relative to the typology needed to monitor the proposed post-2015 indicators of WASH targets. The results signal a lack of international harmonisation and standardisation in census categorisation systems, especially concerning safety, accessibility, and sustainability of services in current census content. This suggests further refinements and harmonisation of future census content may be necessary to reflect ambitions for post-2015 monitoring. PMID:26986472
Yu, Weiyu; Wardrop, Nicola A; Bain, Robert E S; Lin, Yanzhao; Zhang, Ce; Wright, Jim A
2016-01-01
Following the recent expiry of the United Nations' 2015 Millennium Development Goals (MDGs), new international development agenda covering 2030 water, sanitation and hygiene (WASH) targets have been proposed, which imply new demands on data sources for monitoring relevant progress. This study evaluates drinking-water and sanitation classification systems from national census questionnaire content, based upon the most recent international policy changes, to examine national population census's ability to capture drinking-water and sanitation availability, safety, accessibility, and sustainability. In total, 247 censuses from 83 low income and lower-middle income countries were assessed using a scoring system, intended to assess harmonised water supply and sanitation classification systems for each census relative to the typology needed to monitor the proposed post-2015 indicators of WASH targets. The results signal a lack of international harmonisation and standardisation in census categorisation systems, especially concerning safety, accessibility, and sustainability of services in current census content. This suggests further refinements and harmonisation of future census content may be necessary to reflect ambitions for post-2015 monitoring.
Suisman, Jessica L; Thompson, J Kevin; Keel, Pamela K; Burt, S Alexandra; Neale, Michael; Boker, Steven; Sisk, Cheryl; Klump, Kelly L
2014-11-01
Mean-levels of thin-ideal internalization increase during adolescence and pubertal development, but it is unknown whether these phenotypic changes correspond to developmental changes in etiological (i.e., genetic and environmental) risk. Given the limited knowledge on risk for thin-ideal internalization, research is needed to guide the identification of specific types of risk factors during critical developmental periods. The present twin study examined genetic and environmental influences on thin-ideal internalization across adolescent and pubertal development. Participants were 1,064 female twins (ages 8-25 years) from the Michigan State University Twin Registry. Thin-ideal internalization and pubertal development were assessed using self-report questionnaires. Twin moderation models were used to examine if age and/or pubertal development moderate genetic and environmental influences on thin-ideal internalization. Phenotypic analyses indicated significant increases in thin-ideal internalization across age and pubertal development. Twin models suggested no significant differences in etiologic effects across development. Nonshared environmental influences were most important in the etiology of thin-ideal internalization, with genetic, shared environmental, and nonshared environmental accounting for approximately 8%, 15%, and 72%, respectively, of the total variance. Despite mean-level increases in thin-ideal internalization across development, the relative influence of genetic versus environmental risk did not differ significantly across age or pubertal groups. The majority of variance in thin-ideal internalization was accounted for by environmental factors, suggesting that mean-level increases in thin-ideal internalization may reflect increases in the magnitude/strength of environmental risk across this period. Replication is needed, particularly with longitudinal designs that assess thin-ideal internalization across key developmental phases. © 2014 Wiley Periodicals, Inc.
Suisman, Jessica L.; Thompson, J. Kevin; Keel, Pamela K.; Burt, S. Alexandra; Neale, Michael; Boker, Steven; Sisk, Cheryl; Klump, Kelly L.
2014-01-01
Objective Mean-levels of thin-ideal internalization increase during adolescence and pubertal development, but it is unknown whether these phenotypic changes correspond to developmental changes in etiological (i.e., genetic and environmental) risk. Given the limited knowledge on risk for thin-ideal internalization, research is needed to guide the identification of specific types of risk factors during critical developmental periods. The present twin study examined genetic and environmental influences on thin-ideal internalization across adolescent and pubertal development. Method Participants were 1,064 female twins (ages 8–25 years) from the Michigan State University Twin Registry. Thin-ideal internalization and pubertal development were assessed using self-report questionnaires. Twin moderation models were used to examine if age and/or pubertal development moderate genetic and environmental influences on thin-ideal internalization. Results Phenotypic analyses indicated significant increases in thin-ideal internalization across age and pubertal development. Twin models suggested no significant differences in etiologic effects across development. Nonshared environmental influences were most important in the etiology of thin-ideal internalization, with genetic, shared environmental, and nonshared environmental accounting for approximately 8%, 15%, and 72%, respectively, of the total variance. Discussion Despite mean-level increases in thin-ideal internalization across development, the relative influence of genetic versus environmental risk did not differ significantly across age or pubertal groups. The majority of variance in thin-ideal internalization was accounted for by environmental factors, suggesting that mean-level increases in thin-ideal internalization may reflect increases in the magnitude/strength of environmental risk across this period. Replication is needed, particularly with longitudinal designs that assess thin-ideal internalization across key developmental phases. PMID:24962440
Insights into the Aggregation Mechanism of PolyQ Proteins with Different Glutamine Repeat Lengths.
Yushchenko, Tetyana; Deuerling, Elke; Hauser, Karin
2018-04-24
Polyglutamine (polyQ) diseases, including Huntington's disease, result from the aggregation of an abnormally expanded polyQ repeat in the affected protein. The length of the polyQ repeat is essential for the disease's onset; however, the molecular mechanism of polyQ aggregation is still poorly understood. Controlled conditions and initiation of the aggregation process are prerequisites for the detection of transient intermediate states. We present an attenuated total reflection Fourier-transform infrared spectroscopic approach combined with protein immobilization to study polyQ aggregation dependent on the polyQ length. PolyQ proteins were engineered mimicking the mammalian N-terminus fragment of the Huntingtin protein and containing a polyQ sequence with the number of glutamines below (Q11), close to (Q38), and above (Q56) the disease threshold. A monolayer of the polyQ construct was chemically immobilized on the internal reflection element of the attenuated total reflection cell, and the aggregation was initiated via enzymatic cleavage. Structural changes of the polyQ sequence were monitored by time-resolved infrared difference spectroscopy. We observed faster aggregation kinetics for the longer sequences, and furthermore, we could distinguish β-structured intermediates for the different constructs, allowing us to propose aggregation mechanisms dependent on the repeat length. Q11 forms a β-structured aggregate by intermolecular interaction of stretched monomers, whereas Q38 and Q56 undergo conformational changes to various β-structured intermediates, including intramolecular β-sheets. Copyright © 2018 Biophysical Society. Published by Elsevier Inc. All rights reserved.
Beaumelle, Léa; Gimbert, Frédéric; Hedde, Mickaël; Guérin, Annie; Lamy, Isabelle
2015-07-01
Subcellular fractionation of metals in organisms was proposed as a better way to characterize metal bioaccumulation. Here we report the impact of a laboratory exposure to a wide range of field-metal contaminated soils on the subcellular partitioning of metals in the earthworm Aporrectodea caliginosa. Soils moderately contaminated were chosen to create a gradient of soil metal availability; covering ranges of both soil metal contents and of several soil parameters. Following exposure, Cd, Pb and Zn concentrations were determined both in total earthworm body and in three subcellular compartments: cytosolic, granular and debris fractions. Three distinct proxies of soil metal availability were investigated: CaCl2-extractable content dissolved content predicted by a semi-mechanistic model and free ion concentration predicted by a geochemical speciation model. Subcellular partitionings of Cd and Pb were modified along the gradient of metal exposure, while stable Zn partitioning reflected regulation processes. Cd subcellular distribution responded more strongly to increasing soil Cd concentration than the total internal content, when Pb subcellular distribution and total internal content were similarly affected. Free ion concentrations were better descriptors of Cd and Pb subcellular distribution than CaCl2 extractable and dissolved metal concentrations. However, free ion concentrations and soil total metal contents were equivalent descriptors of the subcellular partitioning of Cd and Pb because they were highly correlated. Considering lowly contaminated soils, our results raise the question of the added value of three proxies of metal availability compared to soil total metal content in the assessment of metal bioavailability to earthworm. Copyright © 2015 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Ashton, Karen
2016-01-01
This paper reflects on the methodology used in international comparative education surveys by conducting a systematic review of the European Survey on Language Competences (ESLC). The ESLC was administered from February to March 2011, with final results released in June 2012. The survey tested approximately 55,000 students across 14 European…
ERIC Educational Resources Information Center
Fenton-Smith, Ben; Michael, Rowan
2013-01-01
This paper evaluates a strategy to promote the uptake of support services by international students (ISs) at an Australian university. As part of their assessment, ISs completed a so-called "University Service Reflection Task" (USRT) in a core first-year course. To complete the USRT, all ISs accessed one support service (e.g. language…
ERIC Educational Resources Information Center
Ng, Vinci; Yuen, Mantak
2015-01-01
This paper reflects upon the relevance of Buddhism to counselling in general and to career counseling in particular by discussing a program implemented at an international school in Hong Kong. The authors provide an analysis of the pertinent literature related to relevant concepts within Buddhism. This topic has not yet been adequately researched…
Reflections on the 12th International Transformative Learning Conference
ERIC Educational Resources Information Center
Schapiro, Steven A.; Gallegos, Placida V.; Stashower, Keren; Clark, Donna F.
2017-01-01
This article is a reflective essay that explores the question: What can the content and experience of the conference tell us about the state of theory and practice in the field of TL; where is it today and where it may be going in the future? The 12th International Transformative Learning Conference (ITLC) held October 19-23 at Pacific Lutheran…
Rewarding Teaching Faculty with a Reimbursement Plan
Rouan, Gregory W; Wones, Robert G; Tsevat, Joel; Galla, John H; Dorfmeister, John W; Luke, Robert G
1999-01-01
OBJECTIVE To develop a system for measuring the teaching effort of medical school faculty and to implement a payment system that is based on it. DESIGN An interventional study with outcomes measured before and after the intervention. SETTING A department of internal medicine with a university hospital and an affiliated Veterans Administration hospital. INTERVENTION We assigned a value in teaching units to each teaching activity in proportion to the time expended by the faculty and the intensity of their effort. We then calculated total teaching units for each faculty member in the Division of General Internal Medicine and for combined faculty effort in each subspecialty division in the Department of Medicine. After determining the dollar value for a teaching unit, we distributed discretionary teaching dollars to each faculty member in the Division of General Internal Medicine and to each subspecialty division according to total teaching units. MEASUREMENTS AND MAIN RESULTS The distribution of discretionary teaching dollars was determined. In the year after the intervention, there was a substantial redistribution of discretionary teaching dollars among divisions. Compared with an increase in total discretionary dollars of 11.4%, the change in allocation for individual divisions ranged from an increase of 78.2% to a decrease of −28.5%. Further changes in the second year after the intervention were modest. The distribution of teaching units among divisions was similar to the distribution of questions across subspecialties on the American College of Physicians In-Training Examination (r = .67) and the American Board of Internal Medicine Certifying Examination (r = .88). CONCLUSIONS It is possible to measure the value of teaching effort by medical school faculty and to distribute discretionary teaching funds among divisions according to the value of teaching effort. When this intervention was used at our institution, there were substantial changes in the amounts received by some divisions. We believe that the new distribution more closely approximates the desired distribution because it reflects the desired emphasis on knowledge as measured by two of the most experienced professional groups in internal medicine. We also believe that our method is flexible and adaptable to the needs of most clinical teaching PMID:10354251
NASA Technical Reports Server (NTRS)
Heslin, T.; Heaney, J.; Harper, M.
1974-01-01
The effects of particle size on the optical properties and surface roughness of a glass-balloon-filled, carbon-pigmented paint were studied in order to develop a diffuse-reflecting, low-total-reflectance, low-outgassing black paint. Particle sizes ranged between 20 microns and 74 microns. Surface roughness was found to increase with increasing particle size. Relative total reflectance at near-normal incidence (MgO standard) of the filled paints was less than for the unfilled paint between 230 nm and 1800 nm. Total absolute reflectance at 546 nm decreased with increasing particle size at grazing angles of incidence. Near-normal, total emittance was greater for the filled paints than for the unfilled paint. Specularity decreased with increasing particle size over the range studied.
Loop, Carole
2013-01-01
Carrying out critical business functions without interruption requires a resilient and robust business continuity framework. By embedding an industry-standard incident management system within its business continuity structure, the Bank of Canada strengthened its response plan by enabling timely response to incidents while maintaining a strong focus on business continuity. A total programme approach, integrating the two disciplines, provided for enhanced recovery capabilities. While the value of an effective and efficient response organisation is clear, as demonstrated by emergency events around the world, incident response structures based on normal operating hierarchy can experience unique challenges. The internationally-recognised Incident Command System (ICS) model addresses these issues and reflects the five primary incident management functions, each contributing to the overall strength and effectiveness of the response organisation. The paper focuses on the Bank of Canada's successful implementation of the ICS model as its incident management and continuity of operations programmes evolved to reflect current best practices.
Free-form surface design method for a collimator TIR lens.
Tsai, Chung-Yu
2016-04-01
A free-form (FF) surface design method is proposed for a general axial-symmetrical collimator system consisting of a light source and a total internal reflection lens with two coupled FF boundary surfaces. The profiles of the boundary surfaces are designed using a FF surface construction method such that each incident ray is directed (refracted and reflected) in such a way as to form a specified image pattern on the target plane. The light ray paths within the system are analyzed using an exact analytical model and a skew-ray tracing approach. In addition, the validity of the proposed FF design method is demonstrated by means of ZEMAX simulations. It is shown that the illumination distribution formed on the target plane is in good agreement with that specified by the user. The proposed surface construction method is mathematically straightforward and easily implemented in computer code. As such, it provides a useful tool for the design and analysis of general axial-symmetrical optical systems.
Single-frequency Nd:YAG ring lasers with corner cube prism
NASA Astrophysics Data System (ADS)
Wu, Ke Ying; Yang, Su Hui; Zhao, Chang Ming; Wei, Guang Hui
2000-04-01
Kane and Byer reported the first monolithic non-planar miniature ring lasers in 1985. An intrinsic optical diode enforces unidirectional and hence single-frequency oscillation of this device. It has the advantages of compactness, reliability and high efficiency. We put forward another form of the non-planar ring lasers, in which the corner cube prism is the key element and the Nd:YAG crystal is used as a Porro prism to enclose the ring resonator. The phase shift due to the total internal reflections of the three differently orientated reflection planes of the corner cube prism, Faraday rotation in the Nd:YAG crystal placed in a magnetic field and the different output coupling in S and P polarization form an optical diode and enforce the single- frequency generating. A round trip analysis of the polarization properties of the resonator is made by the evaluation of Jones matrix. The results of our initial experiment are given in the paper.
NASA Technical Reports Server (NTRS)
Piszczor, Michael F., Jr.; Macosko, Robert P.
2000-01-01
A refractive secondary solar concentrator is a non-imaging optical device that accepts focused solar energy from a primary concentrator and redirects that light, by means of refraction and total internal reflection (TIR) into a cavity where the solar energy is used for power and/or propulsion applications. This concept offers a variety of advantages compared to typical reflective secondary concentrators (or the use of no secondary at all): higher optical efficiency, minimal secondary cooling requirements, a smaller cavity aperture, a reduction of outgassing from the cavity and flux tailoring of the solar energy within the heat receiver. During the past 2 years, NASA Lewis has been aggressively developing this concept in support of the NASA Marshall Shooting Star Flight Experiment. This paper provides a brief overview of the advantages and technical challenges associated with the development of a refractive secondary concentrator and the fabrication of a working unit in support of the flight demonstration program.
Performance analysis of higher mode spoof surface plasmon polariton for terahertz sensing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yao, Haizi; Tu, Wanli; Zhong, Shuncong, E-mail: zhongshuncong@hotmail.com
2015-04-07
We investigated the spoof surface plasmon polaritons (SSPPs) on 1D grooved metal surface for terahertz sensing of refractive index of the filling analyte through a prism-coupling attenuated total reflection setup. From the dispersion relation analysis and the finite element method-based simulation, we revealed that the dispersion curve of SSPP got suppressed as the filling refractive index increased, which cause the coupling resonance frequency redshifting in the reflection spectrum. The simulated results for testing various refractive indexes demonstrated that the incident angle of terahertz radiation has a great effect on the performance of sensing. Smaller incident angle will result in amore » higher sensitive sensing with a narrower detection range. In the meanwhile, the higher order mode SSPP-based sensing has a higher sensitivity with a narrower detection range. The maximum sensitivity is 2.57 THz/RIU for the second-order mode sensing at 45° internal incident angle. The proposed SSPP-based method has great potential for high sensitive terahertz sensing.« less
Optical switch based on the electrically controlled liquid crystal interface.
Komar, Andrei A; Tolstik, Alexei L; Melnikova, Elena A; Muravsky, Alexander A
2015-06-01
The peculiarities of the linearly polarized light beam reflection at the interface within the bulk of a nematic liquid crystal (NLC) cell with different orientations of the director are analyzed. Two methods to create the interface are considered. Combination of the planar and homeotropic orientations of the NLC director is realized by means of a spatially structured electrode under the applied voltage. In-plane patterned azimuthal alignment of the NLC director is created by the patterned rubbing alignment technique. All possible orthogonal orientations of the LC director are considered; the configurations for realization of total internal reflection are determined. The revealed relationship between the propagation of optical beams in a liquid crystal material and polarization of laser radiation has enabled realization of the spatial separation for the orthogonally polarized light beams at the interface between two regions of NLC with different director orientations (domains). Owing to variations in the applied voltage and, hence, in the refractive index gradient, the light beam propagation directions may be controlled electrically.
Reflective Writing through the Use of Guiding Questions
ERIC Educational Resources Information Center
Moussa-Inaty, Jase
2015-01-01
Reflections can be seen as powerful tools for growth and intellectual development. It is no surprise that the writing of reflections is common practice at a Federal Institute in the United Arab Emirates (UAE). The research presented sought to explore possible differences in reflective writing once guidelines were presented to a group of interns in…
Publications - GMC 30 | Alaska Division of Geological & Geophysical Surveys
DGGS GMC 30 Publication Details Title: Geochemical analysis (total organic carbon, rock-eval pyrolysis , Geochemical analysis (total organic carbon, rock-eval pyrolysis, vitrinite reflectance and gc/ms chromato (1.3 M) Keywords Pyrolysis; Rock-Eval Pyrolysis; Total Organic Carbon; Vitrinite Reflectance Top of
Publications - GMC 207 | Alaska Division of Geological & Geophysical
DGGS GMC 207 Publication Details Title: Total organic carbon, rock-eval, and vitrinite reflectance data for more information. Bibliographic Reference Unknown, 1993, Total organic carbon, rock-eval, and Report Information gmc207.pdf (165.0 K) Keywords Total Organic Carbon; Vitrinite Reflectance Top of Page
Publications - GMC 60 | Alaska Division of Geological & Geophysical Surveys
DGGS GMC 60 Publication Details Title: Total organic carbon, rock-eval pyrolysis, and vitrinite , Total organic carbon, rock-eval pyrolysis, and vitrinite reflectance geochemical data for the Nechelik (125.0 K) Keywords Pyrolysis; Rock-Eval Pyrolysis; Total Organic Carbon; Vitrinite Reflectance Top of
Publications - GMC 62 | Alaska Division of Geological & Geophysical Surveys
DGGS GMC 62 Publication Details Title: Total organic carbon, rock-eval pyrolysis, and vitrinite . Bibliographic Reference Unknown, 1985, Total organic carbon, rock-eval pyrolysis, and vitrinite reflectance Pyrolysis; Total Organic Carbon; Vitrinite Reflectance Top of Page Department of Natural Resources, Division
Publications - GMC 286 | Alaska Division of Geological & Geophysical
DGGS GMC 286 Publication Details Title: Total organic carbon (TOC), rock-eval, vitrinite reflectance publication sales page for more information. Bibliographic Reference DGSI, Inc., 1999, Total organic carbon Products Report Report Information gmc286.pdf (2.0 M) Keywords Total Organic Carbon; Vitrinite Reflectance
Publications - GMC 59 | Alaska Division of Geological & Geophysical Surveys
DGGS GMC 59 Publication Details Title: Total organic carbon, rock-eval pyrolysis, and vitrinite . Bibliographic Reference Unknown, 1985, Total organic carbon, rock-eval pyrolysis, and vitrinite reflectance -Eval Pyrolysis; Total Organic Carbon; Vitrinite Reflectance Top of Page Department of Natural Resources
The Effect of Pressure and Temperature on Mid-Infrared Sensing of Dissolved Hydrocarbons in Water.
Heath, Charles; Myers, Matthew; Pejcic, Bobby
2017-12-19
Attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy using a polymer coated internal reflection element/waveguide is an established sensor platform for the detection of a range of organic and hydrocarbon molecules dissolved in water. The polymer coating serves two purposes: to concentrate hydrocarbons from the aqueous phase and to exclude water along with other interfering molecules from the surface of the internal reflection element. Crucial to reliable quantification and analytical performance is the calibration of the ATR-FTIR sensor which is commonly performed in water under mild ambient conditions (i.e., 25 °C and 1 atm). However, there is a pressing need to monitor environmental and industrial processes/events that may occur at high pressures and temperatures where this calibration approach is unsuitable. Using a ruggedized optical fiber probe with a diamond-based ATR, we have conducted mid-infrared sensor experiments to understand the influence of high pressure (up to 207 bar) and temperature (up to 80 °C) on the detection of toluene and naphthalene dissolved in water. Using a poly(isobutylene) film, we have shown that the IR spectroscopic response is relatively unaffected by changes in pressure; however, a diminished response was observed with increasing temperature. We reveal that changes in the refractive index of the polymer film with temperature have only a minor effect on sensitivity. A more plausible explanation for the observed significant change in sensor response with temperature is that the partitioning process is exothermic and becomes less favorable with increasing temperature. This Article shows that the sensitivity is relatively invariant to pressure; however, the thermal variations are significant and need to be considered when quantifying the concentration of hydrocarbons in water.
Improvement of Electropolishing of 1100 Al Alloy for Solar Thermal Applications
NASA Astrophysics Data System (ADS)
Aguilar-Sierra, Sara María; Echeverría E, Félix
2018-03-01
Aluminum sheets-based mirrors are finding applicability in high-temperature solar concentrating technologies because they are cost-effective, lightweight and have high mechanical properties. Nonetheless, the reflectance percentages obtained by electropolishing are not close to the reflectance values of the currently used evaporated films. Therefore, controlling key factors affecting electropolishing processes became essential in order to achieve highly reflective aluminum surfaces. This study investigated the effect of both the electropolishing process and previous heat treatment on the total reflectance of the AA 1100 aluminum alloy. An acid electrolyte and a modified Brytal process were evaluated. Total reflectance was measured by means of UV-Vis spectrophotometry. Reflectance values higher than 80% at 600 nm were achieved for both electrolytes. Optical microscopy and scanning electron microscopy images showed uneven dissolution for the acid electropolished samples causing a reflectance drop in the 200-450 nm region. The influence of heat treatment, previously to electropolishing, was tested at two different temperatures and various holding times. It was found that reflectance increases around 15% for the heat-treated and electropolished samples versus the non-heat-treated ones. A heat treatment at low temperature combined with a short holding time was enough to improve the sample total reflectance.
Apparent bandgap shift in the internal quantum efficiency for solar cells with back reflectors
NASA Astrophysics Data System (ADS)
Steiner, M. A.; Perl, E. E.; Geisz, J. F.; Friedman, D. J.; Jain, N.; Levi, D.; Horner, G.
2017-04-01
We demonstrate that in solar cells with highly reflective back mirrors, the measured internal quantum efficiency exhibits a shift in bandgap relative to the measured external quantum efficiency. The shift arises from the fact that the measured reflectance at the front surface includes a superposition of waves reflecting from the front and back surfaces. We quantify the magnitude of the apparent shift and discuss the errors that can result in determination of quantities such as the photocurrent. Because of this apparent shift, it is important the bandgap be determined from the external quantum efficiency.
Apparent bandgap shift in the internal quantum efficiency for solar cells with back reflectors
Steiner, Myles A.; Perl, E. E.; Geisz, J. F.; ...
2017-04-28
Here, we demonstrate that in solar cells with highly reflective back mirrors, the measured internal quantum efficiency exhibits a shift in bandgap relative to the measured external quantum efficiency. The shift arises from the fact that the measured reflectance at the front surface includes a superposition of waves reflecting from the front and back surfaces. We quantify the magnitude of the apparent shift and discuss the errors that can result in determination of quantities such as the photocurrent. Because of this apparent shift, it is important that the bandgap be determined from the external quantum efficiency.
Lepp, Margret; Zorn, CeCelia R; Duffy, Patricia R; Dickson, Rana J
2003-01-01
Reflection, a process grounded in distancing from the self to enhance self-awareness, can be used as a pedagogic activity to promote students' transition to a greater authenticity and professionalism and, therefore, improve patient care and nursing practice. In this international educational project (implemented in 2001) using interactive videoconferencing technology (IVC), Swedish and U.S. nursing students and faculty incorporated reflective journaling, drama in education, photolanguage, and off-air meeting discussions to enhance personal and professional development. Highlights from the literature, a description of the project, and student and faculty appraisals are presented.
Liang, L; Jin, Y X; Zhu, X Q; Zhou, F L; Yang, Y
2018-05-15
Real-time detection and monitoring of the drug resistance of single cells have important significance in clinical diagnosis and therapy. Traditional methods operate a number of times for each individual concentration, and innovation is required for the design of more simple and efficient manipulation platforms with necessary higher sensitivity. Here, we have developed a novel diffused total internal reflection (TIR) method to perform drug metabolism and cytotoxicity analysis of trapped myeloid leukemia cells. Molm-13 cells, a type of acute myeloid leukemia cell, were chosen and injected into the device and fittingly captured by cell traps. Differing from previous studies, a series of different concentrations of azelaic acid (AZA) drug could be used from 0 mM to 50 mM through convection and diffusion processes in a single chip, with each concentration region featuring 50 cells, with a total of 549 cell trapping units. Thanks to the high sensitivity of the TIR method, only cells with the same drug concentration could be illuminated in the detection process. By adjusting the incident angle, we could exactly detect and monitor the drug resistance of the cells using different drug concentrations and the experimental resolution of the drug concentration was as small as 5 mM. Images of the membrane integrity and morphology of the cells in the bright field were measured and we also monitored the cell viabilities in the dark field over 2 hours. The effects of AZA on the Molm-13 cells were explored in different concentrations at the single cell level. Compared with the results of the traditional MTT assay method, the experimental results are more simple and accurate. A cell death of 5% at an AZA concentration of 5 mM was observed after 30 minutes, while a concentration of 40 mM corresponded to a 98% cell death. The designed method in this study provides a novel toolkit to control and monitor drug resistance at the single cell level more easily with higher sensitivity and we believe it has significant potential application in single cell quality assessment and medicine analysis in clinical practice.
NASA Technical Reports Server (NTRS)
Cavitte, Marie G. P.; Blankenship, Donald D.; Young, Duncan A.; Schroeder, Dustin M.; Parrenin, Frederic; Lemeur, Emmanuel; Macgregor, Joseph A.; Siegert, Martin J.
2016-01-01
Several airborne radar-sounding surveys are used to trace internal reflections around the European Project for Ice Coring in Antarctica Dome C and Vostok ice core sites. Thirteen reflections, spanning the last two glacial cycles, are traced within 200 km of Dome C, a promising region for million-year-old ice, using the University of Texas Institute for Geophysics High-Capacity Radar Sounder. This provides a dated stratigraphy to 2318 m depth at Dome C. Reflection age uncertainties are calculated from the radar range precision and signal-to-noise ratio of the internal reflections. The radar stratigraphy matches well with the Multichannel Coherent Radar Depth Sounder (MCoRDS) radar stratigraphy obtained independently. We show that radar sounding enables the extension of ice core ages through the ice sheet with an additional radar-related age uncertainty of approximately 1/3-1/2 that of the ice cores. Reflections are extended along the Byrd-Totten Glacier divide, using University of Texas/Technical University of Denmark and MCoRDS surveys. However, core-to-core connection is impeded by pervasive aeolian terranes, and Lake Vostok's influence on reflection geometry. Poor radar connection of the two ice cores is attributed to these effects and suboptimal survey design in affected areas. We demonstrate that, while ice sheet internal radar reflections are generally isochronal and can be mapped over large distances, careful survey planning is necessary to extend ice core chronologies to distant regions of the East Antarctic ice sheet.
Exploring Dimensions of Critical Reflection in Activist-Facilitator Practice
ERIC Educational Resources Information Center
Hanson, Cindy
2013-01-01
This article explores how 14 diverse, Canadian activist-facilitators working in international development experience and understand "critical reflection" as a component of participatory methodologies in facilitation practices. The findings, based on my doctoral study, demonstrate that although critical reflection is often discussed as…
Reilly, Thomas
2008-02-15
The history of the Journal of Sports Sciences is traced from the antecedents of its initiation to the current time. The developments of the sports sciences at large are reflected in the content of the journal. Its links with the international agenda are described, and related to landmark publications. Special attention is given to the relationships with international bodies, the International Society for Advancement of Kinanthropometry and the World Commission of Science and Sports. The expansion of sport and exercise sciences, both nationally and internationally, was reflected in the increased frequency of publication of the journal. Key areas in the kinanthropometric content are identified and placed in context. The review culminates in the highlighting of likely areas for future research.
NASA Astrophysics Data System (ADS)
Dickinson, Alex; White, N. J.; Caulfield, C. P.
2017-12-01
Bright reflections are observed within the upper 1,000 m of the water column along a seismic reflection profile that traverses the northern margin of the Gulf of Mexico. Independent hydrographic calibration demonstrates that these reflections are primarily caused by temperature changes associated with different water masses that are entrained into the Gulf along the Loop Current. The internal wave field is analyzed by automatically tracking 1,171 reflections, each of which is greater than 2 km in length. Power spectra of the horizontal gradient of isopycnal displacement, ϕξx, are calculated from these tracked reflections. At low horizontal wave numbers (kx<10-2 cpm), ϕξx∝kx-0.2±0.6, in agreement with hydrographic observations of the internal wave field. The turbulent spectral subrange is rarely observed. Diapycnal diffusivity, K, is estimated from the observed internal wave spectral subrange of each tracked reflection using a fine-scale parametrization of turbulent mixing. Calculated values of K vary between 10-8 and 10-4 m2 s-1 with a mean value of K˜4×10-6 m2 s-1. The spatial distribution of turbulent mixing shows that K˜10-7 m2 s-1 away from the shelf edge in the upper 300 m where stratification is strong. Mixing is enhanced by up to 4 orders of magnitude adjacent to the shoaling bathymetry of the continental slope. This overall pattern matches that determined by analyzing nearby suites of CTD casts. However, the range of values recovered by spectral analysis of the seismic image is greater as a consequence of significantly better horizontal resolution.
Lamagna, Jerry; Gleiser, Kari A
2007-01-01
In this paper, we introduce Intra-Relational AEDP (I-R) as an attachment-based experiential approach to trauma treatment. Integrating Accelerated Experiential Dynamic Psychotherapy (AEDP) (Fosha, 2000a,b, 2002, 2003) with ego-state methodology, intra-relational interventions specifically seeks to help clients by (1) fostering capacities for self-regulation through shared states of affective resonance between therapist, client, and dissociated self-states; (2) facilitating authentic, open internal dialogue between self-states which can alter engrained patterns of intra-psychic conflict and self-punishment; (3) developing abilities for self-reflection and emotional processing by co-mingling previously disowned affect and emotional memories with here and now experience; and (4) attending to positive affects evoked through experiences of transformation, self-compassion, and self-affirmation. Drawing from object relations and attachment theory, intra-relational interventions places particular emphasis on internal attachment relationships formed through interactions between the client's subjective selves (internal subjects) and reflective selves (internal objects). Through visual imagery, internal dialogue, and explicit relational techniques, intra-relational interventions aims to develop this subjective-reflective dyad's capacity for reciprocal attunement, resonance, and responsiveness. Such clinical strategies aim to foster healing and psychological integration between the client and heretofore disavowed aspects of self.
Yb:YAG master oscillator power amplifier for remote wind sensing.
Sridharan, A K; Saraf, S; Byer, R L
2007-10-20
We have demonstrated key advances towards a solid-state laser amplifier at 1.03 microm for global remote wind sensing. We designed end-pumped zig-zag slab amplifiers to achieve high gain. We overcame parasitic oscillation limitations using claddings on the slab's total internal reflection (TIR) and edge surfaces to confine the pump and signal light by TIR and allow leakage of amplified spontaneous emission rays that do not meet the TIR condition. This enables e3, e5, and e8 single-, double-, and quadruple-pass small-signal amplifier gain, respectively. The stored energy density is 15.6 J/cm3, a record for a laser-diode end-pumped Yb:YAG zig-zag slab amplifier.
Towards fully automated Identification of Vesicle-Membrane Fusion Events in TIRF Microscopy
NASA Astrophysics Data System (ADS)
Vallotton, Pascal; James, David E.; Hughes, William E.
2007-11-01
Total Internal Reflection Fluorescence Microscopy (TIRFM) is imposing itself as the tool of choice for studying biological activity in close proximity to the plasma membrane. For example, the exquisite selectivity of TIRFM allows monitoring the diffusion of GFP-phogrin vesicles and their recruitment to the plasma membrane in pancreatic β-cells. We present a novel computer vision system for automatically identifying the elusive fusion events of GFP-phogrin vesicles with the plasma membrane. Our method is based on robust object tracking and matched filtering. It should accelerate the quantification of TIRFM data and allow the extraction of more biological information from image data to support research in diabetes and obesity.
Observing the conformation of individual SNARE proteins inside live cells
NASA Astrophysics Data System (ADS)
Weninger, Keith
2010-10-01
Protein conformational dynamics are directly linked to function in many instances. Within living cells, protein dynamics are rarely synchronized so observing ensemble-averaged behaviors can hide details of signaling pathways. Here we present an approach using single molecule fluorescence resonance energy transfer (FRET) to observe the conformation of individual SNARE proteins as they fold to enter the SNARE complex in living cells. Proteins were recombinantly expressed, labeled with small-molecule fluorescent dyes and microinjected for in vivo imaging and tracking using total internal reflection microscopy. Observing single molecules avoids the difficulties of averaging over unsynchronized ensembles. Our approach is easily generalized to a wide variety of proteins in many cellular signaling pathways.
Composite phase ceramic phosphor of Al₂O₃-Ce:YAG for high efficiency light emitting.
Tang, Yanru; Zhou, Shengming; Chen, Chong; Yi, Xuezhuan; Feng, Yue; Lin, Hui; Zhang, Shuai
2015-07-13
We present our achievement which is a ceramic plate phosphorable to produce white light when directly combined with commercially available blue light emitting diodes. The ceramic phase structure is that the Al₂O₃ particle is uniformly distributed in the Ce:YAG matrix. The Al₂O₃-Ce:YAG ceramic phosphor has a better luminous efficacy than the transparent Ce:YAG ceramic phosphor under the same test condition. The Al₂O₃ particle plays an important role in promoting the luminous efficacy. The Al₂O₃ particle changes the propagation of the light in ceramic, and it reduces the total internal reflection. That is why the composite phase ceramic phosphor improves extraction efficiency of light.
Open-source do-it-yourself multi-color fluorescence smartphone microscopy
Sung, Yulung; Campa, Fernando; Shih, Wei-Chuan
2017-01-01
Fluorescence microscopy is an important technique for cellular and microbiological investigations. Translating this technique onto a smartphone can enable particularly powerful applications such as on-site analysis, on-demand monitoring, and point-of-care diagnostics. Current fluorescence smartphone microscope setups require precise illumination and imaging alignment which altogether limit its broad adoption. We report a multi-color fluorescence smartphone microscope with a single contact lens-like add-on lens and slide-launched total-internal-reflection guided illumination for three common tasks in investigative fluorescence microscopy: autofluorescence, fluorescent stains, and immunofluorescence. The open-source, simple and cost-effective design has the potential for do-it-yourself fluorescence smartphone microscopy. PMID:29188104
Resolving the Pinning Force of Nanobubbles with Optical Microscopy
NASA Astrophysics Data System (ADS)
Tan, Beng Hau; An, Hongjie; Ohl, Claus-Dieter
2017-02-01
Many of the remarkable properties of surface nanobubbles, such as unusually small contact angles and long lifetimes, are related to the force that pins them onto their substrates. This pinning force is yet to be quantified experimentally. Here, surface-attached nanobubbles are pulled with an atomic force microscope tip while their mechanical responses are observed with total internal reflection fluorescence microscopy. We estimate that a pinning force on the order of 0.1 μ N is required to unpin a nanobubble from its substrate. The maximum force that the tip can exert on the nanobubble is limited by the stability of the neck pulled from the bubble and is enhanced by the hydrophobicity of the tip.
Back surface reflectors for solar cells
NASA Technical Reports Server (NTRS)
Chai, A. T.
1980-01-01
Sample solar cells were fabricated to study the effects of various back surface reflectors on the device performance. They are typical 50 micrometers thick, space quality, silicon solar cells except for variations of the back contact configuration. The back surfaces of the sample cells are polished to a mirror like finish, and have either conventional full contacts or grid finger contacts. Measurements and evaluation of various metallic back surface reflectors, as well as cells with total internal reflection, are presented. Results indicate that back surface reflectors formed using a grid finger back contact are more effective reflectors than cells with full back metallization and that Au, Ag, or Cu are better back surface reflector metals than Al.
Transparent Solar Concentrator for Flat Panel Display
NASA Astrophysics Data System (ADS)
Yeh, Chia-Hung; Chang, Fuh-Yu; Young, Hong-Tsu; Hsieh, Tsung-Yen; Chang, Chia-Hsiung
2012-06-01
A new concept of the transparent solar concentrator for flat panel display is experimentally demonstrated without adversely affecting the visual effects. The solar concentrator is based on a solar light-guide plate with micro prisms, not only increasing the absorption area of solar energy but also enhancing the conversion efficiency. The incident light is guided by the designed solar light-guide plate according to the total internal reflection (TIR), and converted into electrical power by photovoltaic solar cells. The designed transparent solar concentrator was made and measured with high transparency, namely 94.8%. The developed solar energy system for display can store energy and supply the bias voltage to light on two light-emitting diodes (LEDs) successfully.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hirvonen, Liisa M.; Le Marois, Alix; Suhling, Klaus, E-mail: klaus.suhling@kcl.ac.uk
We perform wide-field time-correlated single photon counting-based fluorescence lifetime imaging (FLIM) with a crossed delay line anode image intensifier, where the pulse propagation time yields the photon position. This microchannel plate-based detector was read out with conventional fast timing electronics and mounted on a fluorescence microscope with total internal reflection (TIR) illumination. The picosecond time resolution of this detection system combines low illumination intensity of microwatts with wide-field data collection. This is ideal for fluorescence lifetime imaging of cell membranes using TIR. We show that fluorescence lifetime images of living HeLa cells stained with membrane dye di-4-ANEPPDHQ exhibit a reducedmore » lifetime near the coverslip in TIR compared to epifluorescence FLIM.« less
Laleh, Leila; Latifi, Sahar; Koushki, Davood; Matin, Marzieh; Javidan, Abbas Norouzi; Yekaninejad, Mir Saeed
2015-01-01
Patients with spinal cord injury (SCI) deal with various restrictive factors regarding their clothing, such as disability and difficulty with access to shopping centers. We designed a questionnaire to assess attention to clothing and impact of its restrictive factors among Iranian patients with SCI (ACIRF-SCI). The ACIRF-SCI has 5 domains: functional, medical, attitude, aesthetic, and emotional. The first 3 domains reflect the impact of restrictive factors (factors that restrict attention to clothing), and the last 2 domains reflect attention to clothing and fashion. Functional restrictive factors include disability and dependence. Medical restrictive factors include existence of specific medical conditions that interfere with clothing choice. Construct validity was assessed by factorial analysis, and reliability was expressed by Cronbach's alpha. A total of 100 patients (75 men and 25 women) entered this study. Patients with a lower injury level had a higher total score (P < .0001), and similarly, patients with paraplegia had higher scores than those with tetraplegia (P < .0001), which illustrates an admissible discriminant validity. Postinjury duration was positively associated with total scores (r = 0.21, P = .04). Construct validity was 0.97, and Cronbach's alpha was 0.61. Iranian patients with SCI who have greater ability and independence experience a lower impact of restrictive factors related to clothing. The ACIRF-SCI reveals that this assumption is statistically significant, which shows its admissible discriminant validity. The measured construct validity (0.97) and reliability (internal consistency expressed by alpha = 0.61) are acceptable.
Laleh, Leila; Koushki, Davood; Matin, Marzieh; Javidan, Abbas Norouzi; Yekaninejad, Mir Saeed
2015-01-01
Background: Patients with spinal cord injury (SCI) deal with various restrictive factors regarding their clothing, such as disability and difficulty with access to shopping centers. Objectives: We designed a questionnaire to assess attention to clothing and impact of its restrictive factors among Iranian patients with SCI (ACIRF-SCI). Methods: The ACIRF-SCI has 5 domains: functional, medical, attitude, aesthetic, and emotional. The first 3 domains reflect the impact of restrictive factors (factors that restrict attention to clothing), and the last 2 domains reflect attention to clothing and fashion. Functional restrictive factors include disability and dependence. Medical restrictive factors include existence of specific medical conditions that interfere with clothing choice. Construct validity was assessed by factorial analysis, and reliability was expressed by Cronbach’s alpha. Results: A total of 100 patients (75 men and 25 women) entered this study. Patients with a lower injury level had a higher total score (P < .0001), and similarly, patients with paraplegia had higher scores than those with tetraplegia (P < .0001), which illustrates an admissible discriminant validity. Postinjury duration was positively associated with total scores (r = 0.21, P = .04). Construct validity was 0.97, and Cronbach’s alpha was 0.61. Conclusion: Iranian patients with SCI who have greater ability and independence experience a lower impact of restrictive factors related to clothing. The ACIRF-SCI reveals that this assumption is statistically significant, which shows its admissible discriminant validity. The measured construct validity (0.97) and reliability (internal consistency expressed by alpha = 0.61) are acceptable. PMID:26363593
ERIC Educational Resources Information Center
Campbell, Heather; Strawser, Michael G.; George, Stephen
2016-01-01
As the movement toward international education continues, institutions must be proficient when reaching and teaching international students. Instructors should engage unique learning styles, address individual student needs, and take part in additional training to effectively teach international student learners. These instructional imperatives…
Zackoff, Matthew; Jerardi, Karen; Unaka, Ndidi; Sucharew, Heidi; Klein, Melissa
2015-06-01
Residents play a critical role in the education of peers and medical students, yet attainment of teaching skills is not routinely assessed. The primary aim of this study was to develop a novel, skill-based Observed Structured Teaching Evaluation (OSTE) and self-assessment survey to measure the impact of a resident-as-teacher curriculum on teaching competency. The secondary aim was to determine interrater reliability of the OSTE. A prospective study quantitatively assessed intern teaching competency via videotaped teaching encounters (videos) before and after a month-long hospital medicine rotation and self-assessment surveys over a 5-month period. The intervention group received the resident-as-teacher curriculum. Videos were evaluated by 2 blinded faculty via an OSTE covering 9 skills within 3 core components: preparation, teaching, and reflection. Pre- to post-HM rotation month differences were evaluated within and between groups using the Wilcoxon signed rank test and Wilcoxon rank-sum test, respectively. Twenty-two of 25 (88%) control and 27 of 28 (96%) intervention interns participated; 100% of participants completed the study. The intervention group's pre-post difference for the total OSTE score and the average self-assessed competence statistically improved; however, no significant difference was seen between groups. The difference in preparation scores was significant for the intervention compared with the control. The OSTE's interrater reliability demonstrated good agreement with weighted kappas of 0.86 for preparation, 0.71 for teaching, and 0.93 for reflection. Implementation of an objective, skill-based OSTE detected observable changes in interns' teaching competency after implementation of a brief resident-as-teacher curriculum. The OSTE's good interrater reliability may allow standardized assessment of skill attainment over time. Copyright © 2015 by the American Academy of Pediatrics.
Stallinga, Hillegonda A; Jansen, Gerard J; Kastermans, Marijke C; Pranger, Albert; Dijkstra, Pieter U; Roodbol, Petrie F
2016-07-01
To explore the focus of nurse practitioners on health care in terms of cure and care. Nurse practitioners are expected to act on the intersection of cure and care. However, in clinical practice and education, a clear model covering this area is lacking; therefore, it is unknown to what extent nurse practitioners are focused on this specific area. Graduate theses may reflect the focus of nurse practitioners. Sequential exploratory mixed method. In total, 413 published abstracts of graduate theses of a Dutch Master of Advanced Nursing Practice (2000-2015) were analysed using the International Classification of Functioning, Disability and Health. Data source included aim, question and outcome of each thesis and graduates' characteristics. A qualitative deductive approach was used for the analyses. Theses were classified as focused on cure, care, or on the intersection of cure and care. A small majority of 53% (N = 219) of the graduate theses addressed patient's health status and could be classified in the International Classification of Functioning, Disability and Health. Of the classified theses, 48% were focused on cure, 39% on the intersection of cure and care and 13% on care. While the percentage of theses addressing health status increased significantly over the 15-year period, the percentage of theses focused on cure, care and on the intersection of cure and care remained the same. The graduate theses reflected that nurse practitioners are increasingly oriented towards patients' health status. However, their focus is predominantly on cure rather than on the intersection of cure and care. © 2016 John Wiley & Sons Ltd.
Needs and availability of snake antivenoms: relevance and application of international guidelines
Scheske, Laura; Ruitenberg, Joost; Bissumbhar, Balram
2015-01-01
Background: Snakebite has recently been declared a global public health emergency. Empirical data showing the true burden of snakebite is lacking. Treatment with specific antivenoms is considered the only cure. However, several factors have led to an ongoing antivenom crisis. This study offers recommendations concerning the improvement of antivenom access and control, by providing an overview of the factors limiting the successful implementation of international guidelines within the international industry and state institutions. It further investigates the reasons for the epidemiological knowledge gap regarding snakebites. Methods: Data for this study was collected using surveys with closed- and open-ended questions, which allowed for descriptive and thematic analysis, respectively. Participants for this study were selected as follows: 46 manufacturers were contacted from the open-access World Health Organization (WHO) Database for antivenom producers; 23 National Health Authorities (NHAs) of high-burden countries were contacted; and 11 poison centers or experts were randomly contacted. Results: In total, responses from 6/46 (13%) manufacturers, 10/23 (43%) NHAs, and 3/11 (27%) poison centers were received. The low response rates had a limiting effect on the coverage of this study, allowing only exploratory conclusions to be drawn. Based on the gathered information, a probable reason for the epidemiological knowledge gap is the low priority given to snakebites on public health agendas, driving interest and funding away from research in this field. As a consequence, the ensuing lack in funding is preventing state institutions and manufacturers from implementing international guidelines to the highest standards. Furthermore, manufacturers indicated that international guidelines were often not applicable in the field, lacking technical information and protocols. Conclusion: Snakebite ranks low on international public health agendas, and partially due to this low priority, NHAs have shown limited efforts in conducting epidemiological studies, training health workers on snakebite management and creating national snakebite management strategies. The lack of NHA involvement is reflected in poor access to appropriate antivenoms as well as a lack of antivenom regulation. Manufacturers are taking positive steps toward full implementation of international guidelines and are improving quality control procedures. However, in order for international guidelines to become truly useful in the field, more technical guidance is required. This study reflects that there is a general lack of knowledge transfer amongst various actors: most producers, health authorities, and experts expect increased and improved communication and guidance from leading international bodies. Due to the low response rates observed in this study, conclusions drawn herein are not representative of the global situation; yet provide an exploratory insight on the difficulties facing antivenom management. PMID:26188809
Numerical simulations of novel high-power high-brightness diode laser structures
NASA Astrophysics Data System (ADS)
Boucke, Konstantin; Rogg, Joseph; Kelemen, Marc T.; Poprawe, Reinhart; Weimann, Guenter
2001-07-01
One of the key topics in today's semiconductor laser development activities is to increase the brightness of high-power diode lasers. Although structures showing an increased brightness have been developed specific draw-backs of these structures lead to a still strong demand for investigation of alternative concepts. Especially for the investigation of basically novel structures easy-to-use and fast simulation tools are essential to avoid unnecessary, cost and time consuming experiments. A diode laser simulation tool based on finite difference representations of the Helmholtz equation in 'wide-angle' approximation and the carrier diffusion equation has been developed. An optimized numerical algorithm leads to short execution times of a few seconds per resonator round-trip on a standard PC. After each round-trip characteristics like optical output power, beam profile and beam parameters are calculated. A graphical user interface allows online monitoring of the simulation results. The simulation tool is used to investigate a novel high-power, high-brightness diode laser structure, the so-called 'Z-Structure'. In this structure an increased brightness is achieved by reducing the divergency angle of the beam by angular filtering: The round trip path of the beam is two times folded using internal total reflection at surfaces defined by a small index step in the semiconductor material, forming a stretched 'Z'. The sharp decrease of the reflectivity for angles of incidence above the angle of total reflection leads to a narrowing of the angular spectrum of the beam. The simulations of the 'Z-Structure' indicate an increase of the beam quality by a factor of five to ten compared to standard broad-area lasers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meemken, Fabian; Müller, Philipp; Hungerbühler, Konrad
Design and performance of a reactor set-up for attenuated total reflection infrared (ATR-IR) spectroscopy suitable for simultaneous reaction monitoring of bulk liquid and catalytic solid-liquid-gas interfaces under working conditions are presented. As advancement of in situ spectroscopy an operando methodology for gas-liquid-solid reaction monitoring was developed that simultaneously combines catalytic activity and molecular level detection at the catalytically active site of the same sample. Semi-batch reactor conditions are achieved with the analytical set-up by implementing the ATR-IR flow-through cell in a recycle reactor system and integrating a specifically designed gas feeding system coupled with a bubble trap. By the usemore » of only one spectrometer the design of the new ATR-IR reactor cell allows for simultaneous detection of the bulk liquid and the catalytic interface during the working reaction. Holding two internal reflection elements (IRE) the sample compartments of the horizontally movable cell are consecutively flushed with reaction solution and pneumatically actuated, rapid switching of the cell (<1 s) enables to quasi simultaneously follow the heterogeneously catalysed reaction at the catalytic interface on a catalyst-coated IRE and in the bulk liquid on a blank IRE. For a complex heterogeneous reaction, the asymmetric hydrogenation of 2,2,2-trifluoroacetophenone on chirally modified Pt catalyst the elucidation of catalytic activity/enantioselectivity coupled with simultaneous monitoring of the catalytic solid-liquid-gas interface is shown. Both catalytic activity and enantioselectivity are strongly dependent on the experimental conditions. The opportunity to gain improved understanding by coupling measurements of catalytic performance and spectroscopic detection is presented. In addition, the applicability of modulation excitation spectroscopy and phase-sensitive detection are demonstrated.« less
Resistance and Disidentification in Reflective Practice with Preservice Teaching Interns
ERIC Educational Resources Information Center
Middleton, Michael; Abrams, Eleanor; Seaman, Jayson
2011-01-01
Teachers who engage in reflective practices are better able to recognize the complexity of teaching, use judgment to choose appropriate strategies for teaching and learning in their specific contexts, and experience improved self-confidence. For these reasons, many teacher education programs emphasize self-reflective practice. Self-reflective…
Axial superresolution via multiangle TIRF microscopy with sequential imaging and photobleaching
Fu, Yan; Winter, Peter W.; Rojas, Raul; Wang, Victor; McAuliffe, Matthew; Patterson, George H.
2016-01-01
We report superresolution optical sectioning using a multiangle total internal reflection fluorescence (TIRF) microscope. TIRF images were constructed from several layers within a normal TIRF excitation zone by sequentially imaging and photobleaching the fluorescent molecules. The depth of the evanescent wave at different layers was altered by tuning the excitation light incident angle. The angle was tuned from the highest (the smallest TIRF depth) toward the critical angle (the largest TIRF depth) to preferentially photobleach fluorescence from the lower layers and allow straightforward observation of deeper structures without masking by the brighter signals closer to the coverglass. Reconstruction of the TIRF images enabled 3D imaging of biological samples with 20-nm axial resolution. Two-color imaging of epidermal growth factor (EGF) ligand and clathrin revealed the dynamics of EGF-activated clathrin-mediated endocytosis during internalization. Furthermore, Bayesian analysis of images collected during the photobleaching step of each plane enabled lateral superresolution (<100 nm) within each of the sections. PMID:27044072
Why be moral? Children's explicit motives for prosocial-moral action
Sengsavang, Sonia; Willemsen, Kayleen; Krettenauer, Tobias
2015-01-01
Recent research on young children's morality has stressed the autonomous and internal nature of children's moral motivation. However, this research has mostly focused on implicit moral motives, whereas children's explicit motives have not been investigated directly. This study examined children's explicit motives for why they want to engage in prosocial actions and avoid antisocial behavior. A total of 195 children aged 4–12 years were interviewed about their motives for everyday prosocial-moral actions, as well as reported on their relationship with their parents. Children's explicit motives to abstain from antisocial behavior were found to be more external and less other-oriented than their motives for prosocial action. Motives that reflected higher levels of internal motivation became more frequent with age. Moreover, positive parent-child relationships predicted more other-oriented motives and greater explication of moral motives. Overall, the study provides evidence that children's explicit moral motivation is far more heterogeneous than prominent theories of moral development (past and present) suggest. PMID:25999880
Why be moral? Children's explicit motives for prosocial-moral action.
Sengsavang, Sonia; Willemsen, Kayleen; Krettenauer, Tobias
2015-01-01
Recent research on young children's morality has stressed the autonomous and internal nature of children's moral motivation. However, this research has mostly focused on implicit moral motives, whereas children's explicit motives have not been investigated directly. This study examined children's explicit motives for why they want to engage in prosocial actions and avoid antisocial behavior. A total of 195 children aged 4-12 years were interviewed about their motives for everyday prosocial-moral actions, as well as reported on their relationship with their parents. Children's explicit motives to abstain from antisocial behavior were found to be more external and less other-oriented than their motives for prosocial action. Motives that reflected higher levels of internal motivation became more frequent with age. Moreover, positive parent-child relationships predicted more other-oriented motives and greater explication of moral motives. Overall, the study provides evidence that children's explicit moral motivation is far more heterogeneous than prominent theories of moral development (past and present) suggest.
Mishra, Anurag; Mishra, Ritu; Gottschalk, Sven; Pal, Robert; Sim, Neil; Engelmann, Joern; Goldberg, Martin; Parker, David
2014-02-19
A series of bimodal metabotropic glutamate-receptor targeted MRI contrast agents has been developed and evaluated, based on established competitive metabotropic Glu receptor subtype 5 (mGluR5) antagonists. In order to directly visualize mGluR5 binding of these agents on the surface of live astrocytes, variations in the core structure were made. A set of gadolinium conjugates containing either a cyanine dye or a fluorescein moiety was accordingly prepared, to allow visualization by optical microscopy in cellulo. In each case, surface receptor binding was compromised and cell internalization observed. Another approach, examining the location of a terbium analogue via sensitized emission, also exhibited nonspecific cell uptake in neuronal cell line models. Finally, biotin derivatives of two lead compounds were prepared, and the specificity of binding to the mGluR5 cell surface receptors was demonstrated with the aid of their fluorescently labeled avidin conjugates, using both total internal reflection fluorescence (TIRF) and confocal microscopy.
Beyond Reflection through an Academic Lens: Refraction and International Experiential Education
ERIC Educational Resources Information Center
Pagano, Monica; Roselle, Laura
2009-01-01
Students today are becoming more interested in international opportunities for study, and are drawn to alternative programs such as international service learning and international internships. These programs, however, must be carefully designed. In this paper, the authors propose using tools that go beyond the traditional understanding of…
Dissolved organochlorine and PAH pollution profiles in Lithuanian and Swedish surface waters.
Bergqvist, Per-Anders; Jegorova, Ilona; Kauneliene, Violeta; Zaliauskiene, Audrone
2007-08-01
In recent decades, knowledge and concern regarding persistent organic pollutants and the environmental hazards they may pose have increased considerably, leading to international agreements such as the United Nations environment program Stockholm convention on persistent organic pollutants (POPs), to minimize further release of POPs into the environment (UNECE Protocol, 1979; UNEP Stockholm convention, 2001; UNECE Convention, 1998). National POP monitoring programs should be designed to identify, characterize and address the release of the POPs listed in the Stockholm convention. However, analyses of grab samples only provide crude snapshots of total concentrations at single points in space and time, which may be highly unrepresentative of average concentrations, and fail to account for differences in the POPs' bioavailability and various other relevant factors. To obtain a better understanding of the fate and availability of pollutants in the environment it is necessary to obtain data regarding their site-specific and regional exposure levels. Exposure levels expressed in terms of total chemical concentrations do not reflect the actual exposure of organisms, and thus may not accurately reflect the true risks posed. Therefore, environmental monitoring programs would be improved by using reliable, integrative sampling methods that would not only allow time-weighted average concentrations of pollutants in the environment to be determined, but also facilitate assessments of the risks these chemicals pose to the environment.
A practical model of thin disk regenerative amplifier based on analytical expression of ASE lifetime
NASA Astrophysics Data System (ADS)
Zhou, Huang; Chyla, Michal; Nagisetty, Siva Sankar; Chen, Liyuan; Endo, Akira; Smrz, Martin; Mocek, Tomas
2017-12-01
In this paper, a practical model of a thin disk regenerative amplifier has been developed based on an analytical approach, in which Drew A. Copeland [1] had evaluated the loss rate of the upper state laser level due to ASE and derived the analytical expression of the effective life-time of the upper-state laser level by taking the Lorentzian stimulated emission line-shape and total internal reflection into account. By adopting the analytical expression of effective life-time in the rate equations, we have developed a less numerically intensive model for predicting and analyzing the performance of a thin disk regenerative amplifier. Thanks to the model, optimized combination of various parameters can be obtained to avoid saturation, period-doubling bifurcation or first pulse suppression prior to experiments. The effective life-time due to ASE is also analyzed against various parameters. The simulated results fit well with experimental data. By fitting more experimental results with numerical model, we can improve the parameters of the model, such as reflective factor which is used to determine the weight of boundary reflection within the influence of ASE. This practical model will be used to explore the scaling limits imposed by ASE of the thin disk regenerative amplifier being developed in HiLASE Centre.
Breaststroke swimmers moderate internal work increases toward the highest stroke frequencies.
Lauer, Jessy; Olstad, Bjørn Harald; Minetti, Alberto Enrico; Kjendlie, Per-Ludvik; Rouard, Annie Hélène
2015-09-18
A model to predict the mechanical internal work of breaststroke swimming was designed. It allowed us to explore the frequency-internal work relationship in aquatic locomotion. Its accuracy was checked against internal work values calculated from kinematic sequences of eight participants swimming at three different self-chosen paces. Model predictions closely matched experimental data (0.58 ± 0.07 vs 0.59 ± 0.05 J kg(-1)m(-1); t(23)=-0.30, P=0.77), which was reflected in a slope of the major axis regression between measured and predicted total internal work whose 95% confidence intervals included the value of 1 (β=0.84, [0.61, 1.07], N=24). The model shed light on swimmers ability to moderate the increase in internal work at high stroke frequencies. This strategy of energy minimization has never been observed before in humans, but is present in quadrupedal and octopedal animal locomotion. This was achieved through a reduced angular excursion of the heaviest segments (7.2 ± 2.9° and 3.6 ± 1.5° for the thighs and trunk, respectively, P<0.05) in favor of the lightest ones (8.8 ± 2.3° and 7.4 ± 1.0° for the shanks and forearms, respectively, P<0.05). A deeper understanding of the energy flow between the body segments and the environment is required to ascertain the possible dependency between internal and external work. This will prove essential to better understand swimming mechanical cost determinants and power generation in aquatic movements. Copyright © 2015 Elsevier Ltd. All rights reserved.
Focusing hard x rays beyond the critical angle of total reflection by adiabatically focusing lenses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patommel, Jens; Klare, Susanne; Hoppe, Robert
In response to the conjecture that the numerical aperture of x-ray optics is fundamentally limited by the critical angle of total reflection, the concept of adiabatically focusing refractive lenses was proposed to overcome this limit. Here, we present an experimental realization of these optics made of silicon and demonstrate that they indeed focus 20 keV x rays to a 18.4 nm focus with a numerical aperture of 1.73(9) × 10 –3 that clearly exceeds the critical angle of total reflection of 1.55 mrad.
Focusing hard x rays beyond the critical angle of total reflection by adiabatically focusing lenses
Patommel, Jens; Klare, Susanne; Hoppe, Robert; ...
2017-03-06
In response to the conjecture that the numerical aperture of x-ray optics is fundamentally limited by the critical angle of total reflection, the concept of adiabatically focusing refractive lenses was proposed to overcome this limit. Here, we present an experimental realization of these optics made of silicon and demonstrate that they indeed focus 20 keV x rays to a 18.4 nm focus with a numerical aperture of 1.73(9) × 10 –3 that clearly exceeds the critical angle of total reflection of 1.55 mrad.
Bioethical Dimensions of International Cooperation for Health: still a controversial issue?
Santana, José Paranaguá de
2017-07-01
This essay stresses the importance of undertaking a critical analysis of international cooperation for health based upon reflections on diplomacy, acknowledging the ethical limits and possibilities of cooperation within this context. It emphasizes the importance of adopting an historical perspective, highlighting the circumstances surrounding the consolidation of the current international system, whereby, after two world wars, the victorious countries created the United Nations Organization, which today brings together all the world's nations, notwithstanding the fact that the majority of countries are in favor of significant changes to its institutional framework. It also stresses the importance of the bioethics dimension, despite the systematic disregard of principles adopted in relevant UN documents, especially in view of inequalities pari passu with asymmetries of knowledge and enjoyment of innovations that separate nations. This reflection also suggests that South-South cooperation is fundamental to the analysis of the inequality and dependence that demarcate North-South and East-West bipolarity. These reflections are, in short, important guiding elements for deepening analysis and resolutions in the arena of international cooperation for health, leaving aside catastrophic visions and idealistic illusions.
The Effect of Polarized Light on the Growth of a Transparent Cell
Jaffe, L. F.
1960-01-01
It is shown that light lost by reflection before entering a clear and homogeneous sphere or infinite cylinder is precisely compensated by light retained within these bodies by internal reflection; compensation means that the total rate of light absorption by infinitely dilute photoreceptors as integrated through the whole of these bodies or even through any concentric or coaxial shell making them up is independent of surface reflection. In the Phycomyces sporangiophore this theorem precludes a reflection explanation of R, the polarization dependence of the light growth response. An alternative explanation based upon anisotropic absorption by the receptors is explored and found tenable. Formulae are derived for R in any transparent cylindrical cell as a function of the constants of anisotropic absorption by the photoreceptors taken as a group (CH' and CL'), of the radial position of the receptors, and of the refractive indices of the cell (n) and of the medium (N). It is inferred that the photoreceptors in the Phycomyces sporangiophore are most absorbent for light vibrating in the direction of a hoop around a barrel. Orientation of the receptors by linkage to the cell wall is then shown to be a plausible explanation of the inferred anisotropy. On the basis of anisotropic reception, it is predicted that R should be constant for any N > n, and it is shown how CH', C,L' and the radial position of the receptors may all be obtained from a careful determination of R as a function of N. PMID:14406508
Grenoble, Zlata; Baldelli, Steven
2013-08-29
The adsorption of the cationic surfactant benzyldimethylhexadecylammonium (BDMHA(+)) chloride was studied at an octadecyltrichlorosilane (OTS)-monolayer-modified silica-water interface by Raman spectroscopy in total internal reflection (TIR) geometry. The present study demonstrates the capabilities of this spectroscopic technique to evaluate thermodynamic and kinetic BDMHA(+)Cl(-) adsorption properties at the hydrophobic silica surface. The surface coverage of BDMHA(+) decreased by 50% at the hydrophobic OTS-silica surface relative to the surface coverage on bare silica; the dominating driving mechanisms for surfactant adsorption were identified as hydrophobic effects and head group charge screening by the electrolyte counterions. Addition of magnesium metal salt (MgCl2) to the aqueous solution (∼ neutral pH) lowered the surface coverage and moderately increased the Langmuir adsorption constants relative to those of the pure surfactant. These trends were previously observed at the hydrophilic, negatively charged silica surface but with a smaller change in the Gibbs free energy of adsorption at the hydrophobic silica surface. The hydrophobic OTS-silica surface properties resulted in shorter times for the surfactant to reach steady-state adsorption conditions compared to the slow adsorption kinetics previously seen with the surfactant at the hydrophilic surface. Adsorption isotherms, based on Raman signal intensities from spectral analysis, were developed according to the Langmuir adsorption model for the pure surfactant at the OTS-silica-water interface; the modified Langmuir model was applied to the surfactant adsorption in the presence of 5, 10, 50, and 100 mM magnesium chloride. Spectral analysis of the Raman scattering intensities and geometric considerations suggests a hemimicelle-type surface aggregate as the most likely surfactant structure at the OTS-silica surface. The different kinetics observed at the hydrophilic versus the hydrophobic silica surface further indicate that the surface charge and potential influence the surfactant diffusion and kinetic rates of adsorption at the silica-water interface.
Pahlavan, Sara; Morad, Marin
2017-09-01
The details of cardiac Ca 2+ signaling within the dyadic junction remain unclear because of limitations in rapid spatial imaging techniques, and availability of Ca 2+ probes localized to dyadic junctions. To critically monitor ryanodine receptors' (RyR2) Ca 2+ nano-domains, we combined the use of genetically engineered RyR2-targeted pericam probes, (FKBP-YCaMP, K d =150nM, or FKBP-GCaMP6, K d =240nM) with rapid total internal reflectance fluorescence (TIRF) microscopy (resolution, ∼80nm). The punctate z-line patterns of FKBP, 2 -targeted probes overlapped those of RyR2 antibodies and sharply contrasted to the images of probes targeted to sarcoplasmic reticulum (SERCA2a/PLB), or cytosolic Fluo-4 images. FKBP-YCaMP signals were too small (∼20%) and too slow (2-3s) to detect Ca 2+ sparks, but the probe was effective in marking where Fluo-4 Ca 2+ sparks developed. FKBP-GCaMP6, on the other hand, produced rapidly decaying Ca 2+ signals that: a) had faster kinetics and activated synchronous with I Ca 3 but were of variable size at different z-lines and b) were accompanied by spatially confined spontaneous Ca 2+ sparks, originating from a subset of eager sites. The frequency of spontaneously occurring sparks was lower in FKBP-GCaMP6 infected myocytes as compared to Fluo-4 dialyzed myocytes, but isoproterenol enhanced their frequency more effectively than in Fluo-4 dialyzed cells. Nevertheless, isoproterenol failed to dissociate FKBP-GCaMP6 from the z-lines. The data suggests that FKBP-GCaMP6 binds predominantly to junctional RyR2s and has sufficient on-rate efficiency as to monitor the released Ca 2+ in individual dyadic clefts, and supports the idea that β-adrenergic agonists may modulate the stabilizing effects of native FKBP on RyR2. Copyright © 2017 Elsevier Ltd. All rights reserved.
A High Precision Survey of the Molecular Dynamics of Mammalian Clathrin-Mediated Endocytosis
Taylor, Marcus J.; Perrais, David; Merrifield, Christien J.
2011-01-01
Dual colour total internal reflection fluorescence microscopy is a powerful tool for decoding the molecular dynamics of clathrin-mediated endocytosis (CME). Typically, the recruitment of a fluorescent protein–tagged endocytic protein was referenced to the disappearance of spot-like clathrin-coated structure (CCS), but the precision of spot-like CCS disappearance as a marker for canonical CME remained unknown. Here we have used an imaging assay based on total internal reflection fluorescence microscopy to detect scission events with a resolution of ∼2 s. We found that scission events engulfed comparable amounts of transferrin receptor cargo at CCSs of different sizes and CCS did not always disappear following scission. We measured the recruitment dynamics of 34 types of endocytic protein to scission events: Abp1, ACK1, amphiphysin1, APPL1, Arp3, BIN1, CALM, CIP4, clathrin light chain (Clc), cofilin, coronin1B, cortactin, dynamin1/2, endophilin2, Eps15, Eps8, epsin2, FBP17, FCHo1/2, GAK, Hip1R, lifeAct, mu2 subunit of the AP2 complex, myosin1E, myosin6, NECAP, N-WASP, OCRL1, Rab5, SNX9, synaptojanin2β1, and syndapin2. For each protein we aligned ∼1,000 recruitment profiles to their respective scission events and constructed characteristic “recruitment signatures” that were grouped, as for yeast, to reveal the modular organization of mammalian CME. A detailed analysis revealed the unanticipated recruitment dynamics of SNX9, FBP17, and CIP4 and showed that the same set of proteins was recruited, in the same order, to scission events at CCSs of different sizes and lifetimes. Collectively these data reveal the fine-grained temporal structure of CME and suggest a simplified canonical model of mammalian CME in which the same core mechanism of CME, involving actin, operates at CCSs of diverse sizes and lifetimes. PMID:21445324
Wang, M D; Axelrod, D
1994-09-01
To study when and where acetylcholine receptor (AChR) clusters appear on developing rat myotubes in primary culture, we have made time-lapse movies of total internal reflection fluorescence (TIRF) overlaid with schlieren transmitted light images. The receptors, including the ones newly incorporated into the membrane, were labeled with rhodamine alpha-bungarotoxin (R-BT) continuously present in the medium. Since TIRF illuminates only cell-substrate contact regions where almost all of the AChR clusters are located, background fluorescence from fluorophores either in the bulk solution or inside the cells can be suppressed. Also, because TIRF minimizes the exposure of the cell interior to light, the healthy survival of the culture during imaging procedures is much enhanced relative to standard epi- (or trans-) illumination. During the experiment, cells were kept alive on the microscope stage at 37 degrees C in an atmosphere of 10% CO2. Two digital images were recorded by a CCD camera every 20 min: the schlieren image of the cells and the TIRF image of the clusters. After background subtraction, the cluster image was displayed in pseudocolors, overlaid onto the cell images, and recorded as 3 frames on a videotape. The final movies are thus able to summarize a week-long experiment in less than a minute. These movies and images show that clusters form often shortly after the myoblast fusion but sometimes much later, and the formation takes place very rapidly (a few hours). The clusters have an average lifetime of around a day, much shorter than the lifetime of a typical myotube. The brightest and largest clusters tend to be the longest-lived. The cluster formation seems to be associated with the contacts of myotubes at the glass substrate, but not with cell-cell contacts or myoblast fusion into myotubes. New AChR continuously appear in preexisting clusters: after photobleaching, the fluorescence of some clusters recovers within an hour.
Koole, Sebastiaan; Christiaens, Veronique; Cosyn, Jan; De Bruyn, Hugo
2016-10-01
Despite the consensus on the importance of reflection for dental professionals, a lack of understanding remains about how students and clinicians should develop their ability to reflect. The aim of this study was to investigate dental students' and mentors' perceptions of mentor groups as an instructional method to facilitate students' reflection in terms of the strategy's learning potential, role of the mentor, group dynamics, and feasibility. At Ghent University in Belgium, third- and fourth-year dental students were encouraged to reflect on their clinical experiences and personal development in three reflective mentor sessions. No preparation or reports afterwards were required; students needed only to participate in the sessions. Sessions were guided by trained mentors to establish a safe environment, frame clinical discussions, and stimulate reflection. Students' and mentors' perceptions of the experience were assessed with a 17-statement questionnaire with response options on a five-point Likert scale (1=totally disagree to 5=totally agree). A total of 50 students and eight mentors completed the questionnaire (response rates 81% and 89%, respectively). Both students and mentors had neutral to positive perceptions concerning the learning potential, role of the mentor, group dynamics, and feasibility. The mean ideal total time for sessions in a year was 99 minutes (third-year students), 111 minutes (fourth-year students), and 147 minutes (mentors). Reported reflective topics related to patient management, frustrations, and practice of dentistry. Overall mean appreciation for the experience ranged from 14.50 to 15.14 on the 20-point scale. These findings about students' and mentors' positive perceptions of the experience suggest that mentor groups may be a potentially valuable strategy to promote dental students' reflection.
A validation study of public health knowledge, skills, social responsibility and applied learning.
Vackova, Dana; Chen, Coco K; Lui, Juliana N M; Johnston, Janice M
2018-06-22
To design and validate a questionnaire to measure medical students' Public Health (PH) knowledge, skills, social responsibility and applied learning as indicated in the four domains recommended by the Association of Schools & Programmes of Public Health (ASPPH). A cross-sectional study was conducted to develop an evaluation tool for PH undergraduate education through item generation, reduction, refinement and validation. The 74 preliminary items derived from the existing literature were reduced to 55 items based on expert panel review which included those with expertise in PH, psychometrics and medical education, as well as medical students. Psychometric properties of the preliminary questionnaire were assessed as follows: frequency of endorsement for item variance; principal component analysis (PCA) with varimax rotation for item reduction and factor estimation; Cronbach's Alpha, item-total correlation and test-retest validity for internal consistency and reliability. PCA yielded five factors: PH Learning Experience (6 items); PH Risk Assessment and Communication (5 items); Future Use of Evidence in Practice (6 items); Recognition of PH as a Scientific Discipline (4 items); and PH Skills Development (3 items), explaining 72.05% variance. Internal consistency and reliability tests were satisfactory (Cronbach's Alpha ranged from 0.87 to 0.90; item-total correlation > 0.59). Lower paired test-retest correlations reflected instability in a social science environment. An evaluation tool for community-centred PH education has been developed and validated. The tool measures PH knowledge, skills, social responsibilities and applied learning as recommended by the internationally recognised Association of Schools & Programmes of Public Health (ASPPH).
Touch Sensor Responds to Contact Pressure
NASA Technical Reports Server (NTRS)
Bejczy, A. K.
1982-01-01
Optical tactile sensor for mechanical hands senses contact pressure via change in light reflected from an elastic covering. Pressure against a cell cover causes distortion, which changes internal reflection of light. Change is sensed by detector, and output signal informs operator of contact. The greater the pressure and distortion, the greater the change in light reflection.
ERIC Educational Resources Information Center
Lamm, Alexa J.; Cannon, Karen J.; Roberts, T. Grady; Irani, Tracy A.; Snyder, Lori J. Unruh; Brendemuhl, Joel; Rodriguez, Mary T.
2011-01-01
Experiential learning techniques have been used in agricultural education programs for decades. An essential part of this experiential learning process is reflection. Kolb (1984) stated "knowledge results from the combination of grasping experience and transforming it" (p. 41) in a process that involves using reflection. Few researchers…
ERIC Educational Resources Information Center
Lepp, Margret; Zorn, CeCelia R.; Duffy, Patricia R.; Dickson, Rana J.
2003-01-01
A nursing course connected U.S. and Swedish sites via interactive videoconferencing and used reflective methods (journaling, drama, photo language) and off-air group discussion. Evaluation by five Swedish and seven U.S. students suggested how reflection moved students toward greater authenticity and professionalism in nursing practice. (Contains…
Reflection and Non-Reflection of Particle Wavepackets
ERIC Educational Resources Information Center
Cox, Timothy; Lekner, John
2008-01-01
Exact closed-form solutions of the time-dependent Schrodinger equation are obtained, describing the propagation of wavepackets in the neighbourhood of a potential. Examples given include zero reflection, total reflection and partial reflection of the wavepacket, for the sech[superscript 2]x/a, 1/x[superscript 2] and delta(x) potentials,…
Dhanapal, Arun Prabhu; Ray, Jeffery D; Singh, Shardendu K; Hoyos-Villegas, Valerio; Smith, James R; Purcell, Larry C; Fritschi, Felix B
2016-08-04
Chlorophyll is a major component of chloroplasts and a better understanding of the genetic basis of chlorophyll in soybean [Glycine max (L.) Merr.] might contribute to improving photosynthetic capacity and yield in regions with adverse environmental conditions. A collection of 332 diverse soybean genotypes were grown in 2 years (2009 and 2010) and chlorophyll a (eChl_A), chlorophyll b (eChl_B), and total chlorophyll (eChl_T) content as well as chlorophyll a/b ratio (eChl_R) in leaf tissues were determined by extraction and spectrometric determination. Total chlorophyll was also derived from canopy spectral reflectance measurements using a model of wavelet transformed spectra (tChl_T) as well as with a spectral reflectance index (iChl_T). A genome-wide associating mapping approach was employed using 31,253 single nucleotide polymorphisms (SNPs) to identify loci associated with the extract based eChl_A, eChl_B, eChl_R and eChl_T measurements and the two canopy spectral reflectance-based methods (tChl_T and iChl_T). A total of 23 (14 loci), 15 (7 loci) and 14 SNPs (10 loci) showed significant association with eChl_A, eChl_B and eChl_R respectively. A total of 52 unique SNPs were significantly associated with total chlorophyll content based on at least one of the three approaches (eChl_T, tChl_T and iChl_T) and likely tagged 27 putative loci for total chlorophyll content, four of which were indicated by all three approaches. Results presented here show that markers for chlorophyll traits can be identified in soybean using both extract-based and canopy spectral reflectance-based phenotypes, and confirm that high-throughput phenotyping-amenable canopy spectral reflectance measurements can be used for association mapping.
Interns reflect: the effect of formative assessment with feedback during pre-internship.
McKenzie, Susan; Burgess, Annette; Mellis, Craig
2017-01-01
It is widely known that the opportunity for medical students to be observed and to receive feedback on their procedural skills performance is variable in the senior years. To address this problem, we provided our Pre-Intern (PrInt) students with "one-to-one" formative feedback on their ability to perform urethral catheterization (U/C) and hypothesized that their future practice of U/C as interns would benefit. This study sought to evaluate the performance and practice of interns in U/C 4-5 months after having received feedback on their performance of U/C as PrInt students. Between 2013 and 2014, two cohorts of interns, (total n=66) who had received recent formative feedback on their U/C performance as PrInt students at Central Clinical School, were invited to complete an anonymous survey. The survey contained nine closed unvalidated questions and one open-ended question, designed to allow interns to report on their current practice of U/C. Forty-one out of 66 interns (62%) completed the survey. Thirty-five out of 41 respondents (85%) reported that the assessment with feedback during their PrInt term was beneficial to their practice. Thirty of 41 (73%) reported being confident to perform U/C independently. Eleven out of 41 respondents (27%) reported that they had received additional training at intern orientation. Nine of the 11 interns (82%) reported that they had a small, but a significant, increase in confidence to perform U/C when compared with the 30 of the 41 respondents (73%) who had not ( p =0.03). Our results substantiate our hypothesis that further education by assessment with feedback in U/C during PrInt was of benefit to interns' performance. Additional educational reinforcement in U/C during intern orientation further improved intern confidence. Our results indicate that extra pre- and post-graduation procedural skills training, with feedback, should be universal.
Analysis of multiple internal reflections in a parallel aligned liquid crystal on silicon SLM.
Martínez, José Luis; Moreno, Ignacio; del Mar Sánchez-López, María; Vargas, Asticio; García-Martínez, Pascuala
2014-10-20
Multiple internal reflection effects on the optical modulation of a commercial reflective parallel-aligned liquid-crystal on silicon (PAL-LCoS) spatial light modulator (SLM) are analyzed. The display is illuminated with different wavelengths and different angles of incidence. Non-negligible Fabry-Perot (FP) effect is observed due to the sandwiched LC layer structure. A simplified physical model that quantitatively accounts for the observed phenomena is proposed. It is shown how the expected pure phase modulation response is substantially modified in the following aspects: 1) a coupled amplitude modulation, 2) a non-linear behavior of the phase modulation, 3) some amount of unmodulated light, and 4) a reduction of the effective phase modulation as the angle of incidence increases. Finally, it is shown that multiple reflections can be useful since the effect of a displayed diffraction grating is doubled on a beam that is reflected twice through the LC layer, thus rendering gratings with doubled phase modulation depth.
NASA Astrophysics Data System (ADS)
Williams, Christopher
2000-07-01
The nature of international education as a field of studies has been affected by global changes over the past decade. At the same time, the concept of global security has emerged, bringing together studies related to development, the environment and the understanding of violence. Although much of the education literature reflects the global security approach, it is not a field that has been subjected to much analysis as a whole. This paper provides an assessment of international education as a discipline, and outlines the global security framework. It examines how this framework is reflected in the forms of analysis used by international educationists. Finally it suggests how the central purpose of global security, namely ensuring human survival, could be adopted within international education to provide a clear sense of direction. This has specific implications for such areas as curriculum, assessment, educational provision and planning.
Karlowatz, M; Kraft, M; Mizaikoff, B
2004-05-01
Attenuated total reflection mid-infrared spectroscopy is applied for simultaneous detection and quantification of the environmentally relevant analytes benzene, toluene, and the three xylene isomers. The analytes are enriched into a thin polymer membrane coated onto the surface of an internal reflection waveguide, which is exposed to the aqueous sample. Direct detection of analytes permeating into the polymer coating is performed by utilizing evanescent field spectroscopy in the fingerprint range (>10 microm) of the mid-infrared (MIR) spectrum (3-20 microm) without additional sample preparation. All investigated compounds are characterized by well-separated absorption features in the evaluated wavelength regime. Hence, data evaluation was performed by integration of the respective absorption peaks. Limits of detection lower than 20 ppb (v/v) for all xylene isomers, 45 ppb (v/v) for benzene, and 80 ppb (v/v) for toluene have been achieved. The straightforward experimental setup and the achieved detection limits for these environmentally relevant volatile organic compounds in the low-ppb concentration range reveal a substantial potential of MIR evanescent field sensing devices for on-line in situ environmental analysis.
Tunable diode-laser heterodyne spectrometer for remote observations near 8 microns
NASA Technical Reports Server (NTRS)
Glenar, D.; Kostiuk, T.; Jennings, D. E.; Buhl, D.; Mumma, M. J.
1982-01-01
A diode-laser-based, ultrahigh resolution IR heterodyne spectrometer for laboratory and field use has been developed for operation between 7.5 and 8.5 microns. The local oscillator is a PbSe tunable diode laser kept continuously at operating temperatures of 12-60 K using a closed-cycle cooler. The laser output frequency is controlled and stabilized using a high-precision diode current supply, constant temperature controller, and a shock isolator mounted between the refrigerator cold tip and the diode mount. The system largely employs reflecting optics to minimize losses from internal reflection and absorption and to eliminate chromatic effects. Spectral analysis of the diode-laser output between 0 and 1 GHz reveals excess noise at many diode current settings, which limits the IR spectral regions over which useful heterodyne operation can be achieved. Observations have been made of atmospheric N2O, O3, and CH4 between 1170 and 1200/cm, using both a single-frequency swept IF channel and a 64-channel RF spectral line receiver with a total IF coverage of 1600 MHz.
Contrasting mechanisms of growth in two model rod-shaped bacteria
Billaudeau, Cyrille; Chastanet, Arnaud; Yao, Zhizhong; Cornilleau, Charlène; Mirouze, Nicolas; Fromion, Vincent; Carballido-López, Rut
2017-01-01
How cells control their shape and size is a long-standing question in cell biology. Many rod-shaped bacteria elongate their sidewalls by the action of cell wall synthesizing machineries that are associated to actin-like MreB cortical patches. However, little is known about how elongation is regulated to enable varied growth rates and sizes. Here we use total internal reflection fluorescence microscopy and single-particle tracking to visualize MreB isoforms, as a proxy for cell wall synthesis, in Bacillus subtilis and Escherichia coli cells growing in different media and during nutrient upshift. We find that these two model organisms appear to use orthogonal strategies to adapt to growth regime variations: B. subtilis regulates MreB patch speed, while E. coli may mainly regulate the production capacity of MreB-associated cell wall machineries. We present numerical models that link MreB-mediated sidewall synthesis and cell elongation, and argue that the distinct regulatory mechanism employed might reflect the different cell wall integrity constraints in Gram-positive and Gram-negative bacteria. PMID:28589952
Thermal lens elimination by gradient-reduced zone coupling of optical beams
Page, Ralph H.; Beach, Raymond J.
2000-01-01
A thermal gradient-reduced-zone laser includes a laser medium and an optically transparent plate with an index of refraction that is less than the index of refraction of the laser medium. The pump face of the laser medium is bonded to a surface of the optically transparent member. Pump light is directed through the transparent plate to optically pump the solid state laser medium. Heat conduction is mainly through the surface of the laser medium where the heat is introduced by the pump light. Heat flows in a direction opposite to that of the pump light because the side of the laser medium that is opposite to that of the pump face is not in thermal contact with a conductor and thus there is no heat flux (and hence, no temperature gradient), thus producing a thermal gradient-reduced zone. A laser cavity is formed around the laser medium such that laser light oscillating within the laser cavity reflects by total-internal-reflection from the interface between the pump face and the optically transparent plate and enters and exits through a thermal gradient-reduced zone.
NASA Astrophysics Data System (ADS)
Wang, Pengfei; Brambilla, Gilberto; Semenova, Yuliya; Wu, Qiang; Zheng, Jie; Farrell, Gerald
2011-08-01
The well known beam propagation method (BPM) has become one of the most useful, robust and effective numerical simulation tools for the investigation of guided-wave optics, for example integrated optical waveguides and fiber optic devices. In this paper we examine the use of the 2D and 3D wide angle-beam propagation method (WA-BPM) combined with the well known perfectly matched layer (PML) boundary conditions as a tool to analyze TIR based optical switches, in particular the relationship between light propagation and the geometrical parameters of a TIR based optical switch. To analyze the influence of the length and the width of the region in which the refractive index can be externally controlled, the 3D structure of a 2x2 TIR optical switch is firstly considered in 2D using the effective index method (EIM). Then the influence of the etching depth and the tilt angle of the reflection facet on the switch performance are investigated with a 3D model.
The Belle II imaging Time-of-Propagation (iTOP) detector
NASA Astrophysics Data System (ADS)
Fast, J.; Belle II Barrel Particle Identification Group
2017-12-01
High precision flavor physics measurements are an essential complement to the direct searches for new physics at the LHC ATLAS and CMS experiments. Such measurements will be performed using the upgraded Belle II detector that will take data at the SuperKEKB accelerator. With 40x the luminosity of KEKB, the detector systems must operate efficiently at much higher rates than the original Belle detector. A central element of the upgrade is the barrel particle identification system. Belle II has built and installed an imaging-Time-of-Propagation (iTOP) detector. The iTOP uses quartz optics as Cherenkov radiators. The photons are transported down the quartz bars via total internal reflection with a spherical mirror at the forward end to reflect photons to the backward end where they are imaged onto an array of segmented Micro-Channel Plate Photo-Multiplier Tubes (MCP-PMTs). The system is read out using giga-samples per second waveform sampling Application-Specific Integrated Circuits (ASICs). The combined timing and spatial distribution of the photons for each event are used to determine particle species. This paper provides an overview of the iTOP system.
Multi-phase-fluid discrimination with local fibre-optical probes: I. Liquid/liquid flows
NASA Astrophysics Data System (ADS)
Fordham, E. J.; Holmes, A.; Ramos, R. T.; Simonian, S.; Huang, S.-M.; Lenn, C. P.
1999-12-01
We demonstrate the use of a novel design of fibre-optical sensor (or `local probe') for immiscible-fluid discrimination in multi-phase flows. These probes are made from standard silica fibres with plane oblique facets polished at the fibre tip, with various surface treatments, including a crucial one for wettability control. Total internal reflection is used to distinguish drops, bubbles or other regions of fluid in multi-phase flows, on the basis of refractive-index contrast. Such probes have quasi-binary outputs; we demonstrate in this paper their use in distinguishing water from oil (kerosene) in oil/water two-phase flows and compare the results with those obtained from a simple cleaved fibre relying on the (small) difference in Fresnel reflectivity for discrimination. Quantitative accuracy is demonstrated by comparison of profiles, across a pipe diameter, of local, time-averaged volume fractions (`hold-ups'), with pipe-averaged hold-ups determined from a carefully calibrated gradio-manometer in a fully developed region of the flow. Companion papers deal with the sensors used and results achieved in gas/liquid flows and three-phase flows.
Online, automatic, ionospheric maps: IRI-PLAS-MAP
NASA Astrophysics Data System (ADS)
Arikan, F.; Sezen, U.; Gulyaeva, T. L.; Cilibas, O.
2015-04-01
Global and regional behavior of the ionosphere is an important component of space weather. The peak height and critical frequency of ionospheric layer for the maximum ionization, namely, hmF2 and foF2, and the total number of electrons on a ray path, Total Electron Content (TEC), are the most investigated and monitored values of ionosphere in capturing and observing ionospheric variability. Typically ionospheric models such as International Reference Ionosphere (IRI) can provide electron density profile, critical parameters of ionospheric layers and Ionospheric electron content for a given location, date and time. Yet, IRI model is limited by only foF2 STORM option in reflecting the dynamics of ionospheric/plasmaspheric/geomagnetic storms. Global Ionospheric Maps (GIM) are provided by IGS analysis centers for global TEC distribution estimated from ground-based GPS stations that can capture the actual dynamics of ionosphere and plasmasphere, but this service is not available for other ionospheric observables. In this study, a unique and original space weather service is introduced as IRI-PLAS-MAP from http://www.ionolab.org
78 FR 63433 - International Mailing Services: Proposed Price Changes-CPI
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-24
... POSTAL SERVICE 39 CFR Part 20 International Mailing Services: Proposed Price Changes--CPI AGENCY... mailing services price adjustments with the Postal Regulatory Commission (PRC), effective on January 26... Postal Service, International Mail Manual (IMM[supreg]) to reflect these new price changes. DATES: We...
78 FR 63434 - International Mailing Services: Proposed Price Changes-Exigent
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-24
... POSTAL SERVICE 39 CFR Part 20 International Mailing Services: Proposed Price Changes--Exigent... notice of mailing services price adjustments with the Postal Regulatory Commission (PRC), effective on... United States Postal Service, International Mail Manual (IMM[supreg]) to reflect these new price changes...
Larsen, Carolyn M.; Issa, Meltiady; Croghan, Ivana T.; Buechler, Tamara E.; Burton, M. Caroline
2014-01-01
Objectives To survey internal medicine physicians and residents who have completed residency in three different eras of medical training regarding their experiences during their intern year and their perceptions of duty-hour reform. Methods An online survey was administered to 268 residents, fellows, and staff physicians who had completed or were completing residency during one of three eras of training: before the 80-hour work week, after the 80-hour work week (instituted in 2003), and after the 16-hour limit on continuous shifts for interns (instituted in 2011). The survey assessed experiences during their intern year of residency and perceptions regarding resident duty-hour reform. Results The majority of respondents (n = 32; 54%) indicated that duty-hour restrictions would result in residents being less prepared for their future careers. In addition, 36% (n = 21) of respondents anticipated a decrease in the quality of patient care under the restricted duty hours. A total of 41% (n = 24) were undecided regarding the impact of duty-hour reform on patient care. Respondents reported time spent on independent study, research, and conference attendance did not increase following the institution of duty-hour restrictions. Conclusions Survey responses indicated that after 18 months of experience with the Accreditation Council for Graduate Medical Education duty-hour restrictions, physician opinions were mixed and a substantial number remain undecided regarding the impact of duty-hour restrictions on resident career preparedness and the quality of patient care. PMID:24945179
How is organ transplantation depicted in internal medicine and transplantation journals.
Durand, Céline; Duplantie, Andrée; Chabot, Yves; Doucet, Hubert; Fortin, Marie-Chantal
2013-10-02
In their book Spare Parts, published in 1992, Fox and Swazey criticized various aspects of organ transplantation, including the routinization of the procedure, ignorance regarding its inherent uncertainties, and the ethos of transplant professionals. Using this work as a frame of reference, we analyzed articles on organ transplantation published in internal medicine and transplantation journals between 1995 and 2008 to see whether Fox and Swazey's critiques of organ transplantation were still relevant. Using the PubMed database, we retrieved 1,120 articles from the top ten internal medicine journals and 4,644 articles from the two main transplantation journals (Transplantation and American Journal of Transplantation). Out of the internal medicine journal articles, we analyzed those in which organ transplantation was the main topic (349 articles). A total of 349 articles were randomly selected from the transplantation journals for content analysis. In our sample, organ transplantation was described in positive terms and was presented as a routine treatment. Few articles addressed ethical issues, patients' experiences and uncertainties related to organ transplantation. The internal medicine journals reported on more ethical issues than the transplantation journals. The most important ethical issues discussed were related to the justice principle: organ allocation, differential access to transplantation, and the organ shortage. Our study provides insight into representations of organ transplantation in the transplant and general medical communities, as reflected in medical journals. The various portrayals of organ transplantation in our sample of articles suggest that Fox and Swazey's critiques of the procedure are still relevant.
Larsen, Carolyn M; Issa, Meltiady; Croghan, Ivana T; Buechler, Tamara E; Burton, M Caroline
2014-06-01
To survey internal medicine physicians and residents who have completed residency in three different eras of medical training regarding their experiences during their intern year and their perceptions of duty-hour reform. An online survey was administered to 268 residents, fellows, and staff physicians who had completed or were completing residency during one of three eras of training: before the 80-hour work week, after the 80-hour work week (instituted in 2003), and after the 16-hour limit on continuous shifts for interns (instituted in 2011). The survey assessed experiences during their intern year of residency and perceptions regarding resident duty-hour reform. The majority of respondents (n = 32; 54%) indicated that duty-hour restrictions would result in residents being less prepared for their future careers. In addition, 36% (n = 21) of respondents anticipated a decrease in the quality of patient care under the restricted duty hours. A total of 41% (n = 24) were undecided regarding the impact of duty-hour reform on patient care. Respondents reported time spent on independent study, research, and conference attendance did not increase following the institution of duty-hour restrictions. Survey responses indicated that after 18 months of experience with the Accreditation Council for Graduate Medical Education duty-hour restrictions, physician opinions were mixed and a substantial number remain undecided regarding the impact of duty-hour restrictions on resident career preparedness and the quality of patient care.
The Beck Cognitive Insight Scale (BCIS): translation and validation of the Taiwanese version.
Kao, Yu-Chen; Liu, Yia-Ping
2010-04-09
Over the last few decades, research concerning the insight of patients with schizophrenia and its relationships with other clinical variables has been given much attention in the clinical setting. Since that time, a series of instruments assessing insight have been developed. The purpose of this study was to examine the reliability and validity of the Taiwanese version of the Beck Cognitive Insight Scale (BCIS). The BCIS is a self-administered instrument designed to evaluate cognitive processes that involves reevaluating patients' anomalous experiences and specific misinterpretations. The English language version of the BCIS was translated into Taiwanese for use in this study. A total of 180 subjects with and without psychosis completed the Taiwanese version of the BCIS and additional evaluations to assess researcher-rated insight scales and psychopathology. Psychometric properties (factor structures and various types of reliability and validity) were assessed for this translated questionnaire. Overall, the Taiwanese version of the BCIS showed good reliability and stability over time. This translated scale comprised a two-factor solution corresponding to reflective attitude and certain attitude subscales. Following the validation of the internal structure of the scale, we obtained an R-C (reflective attitude minus certain attitude) index of the translated BCIS, representing the measurement of cognitive insight by subtracting the score of the certain attitude subscale from that of the reflective attitude subscale. As predicted, the differences in mean reflective attitude, certain attitude and R-C index between subjects with and without psychosis were significant. Our data also demonstrated that psychotic patients were significantly less reflective, more confident in their beliefs, and had less cognitive insight compared with nonpsychotic control groups. In light of these findings, we believe that the Taiwanese version of BCIS is a valid and reliable instrument for the assessment of cognitive insight in psychotic patients.
NASA Astrophysics Data System (ADS)
Tao, Xuemei; He, Yong
2006-09-01
The internal quality of tomato such as acidity and sugar content is important to its taste thus influences the market. The objective of this paper was to demonstrate the feasibility of using a near-infrared spectroscopy (NIRS) to investigate the relationship between sugar content and acidity of tomato and absorption spectra. The N1RS reflectance of nondestructive tomatoes was measured with a Visible/NJR spectrophotometer in 325-1075 nm range. The sugar content and acidity of tomato were obtained with a handhold sugar content meter and a PH meter. The reflectance data set was recorded and analyzed with some mathematic methods. The PLS (Partial least squares) calibration method was developed for converting the NIRS reflectance of tomato into the data which determined the acidity value. BP (Back propagation) neural network was used to set up the relationship between the NIRS reflectance of tomato and sugar content. The acidity values were detected with an accuracy of 9O% and the sugar contents determined by the BP network were also very close to the measurements (coefficient of correlation r2=0.8764). NW spectra analysis would be very useful in the nondestructive internal quality inspecting of tomato.
Review of methodology and technology available for the detection of extrasolar planetary systems
NASA Technical Reports Server (NTRS)
Tarter, J. C.; Black, D. C.; Billingham, J.
1985-01-01
Four approaches exist for the detection of extrasolar planets. According to the only direct method, the planet is imaged at some wavelength in a manner which makes it possible to differentiate its own feeble luminosity (internal energy source plus reflected starlight) from that of the nearby host star. The three indirect methods involve the detection of a planetary mass companion on the basis of the observable effects it has on the host star. A search is conducted regarding the occurrence of regular, periodic changes in the stellar spatial motion (astrometric method) or the velocity of stellar emission line spectra (spectroscopic method) or in the apparent total stellar luminosity (photometric method). Details regarding the approaches employed for implementing the considered methods are discussed.
Study of a coronagraphic mask using evanescent waves.
Buisset, Christophe; Rabbia, Yves; Lepine, Thierry; Alagao, Mary-Angelie; Ducrot, Elsa; Poshyachinda, Saran; Soonthornthum, Boonrucksar
2017-04-03
The evanescent wave coronagraph (EvWaCo) is a specific kind of band-limited coronagraph using the frustrated total internal reflection phenomenon to produce the coronagraphic effect (removing starlight from the image plane in order to make the stellar environment detectable). In this paper, we present a theoretical and experimental study of the EvWaCo coronagraphic mask. First, we calculate the theoretical transmission and we show that this mask is partially achromatic. Then, we present the experimental results obtained in unpolarized light at the wavelength λ≈900 nm and relative spectral bandwidth Δλ/λ≈6%. In particular, we show that the coronagraph provides a contrast down to a few 10-6 at an angular distance of about ten Airy radii.
Processive movement of MreB-associated cell wall biosynthetic complexes in bacteria.
Domínguez-Escobar, Julia; Chastanet, Arnaud; Crevenna, Alvaro H; Fromion, Vincent; Wedlich-Söldner, Roland; Carballido-López, Rut
2011-07-08
The peptidoglycan cell wall and the actin-like MreB cytoskeleton are major determinants of cell shape in rod-shaped bacteria. The prevailing model postulates that helical, membrane-associated MreB filaments organize elongation-specific peptidoglycan-synthesizing complexes along sidewalls. We used total internal reflection fluorescence microscopy to visualize the dynamic relation between MreB isoforms and cell wall synthesis in live Bacillus subtilis cells. During exponential growth, MreB proteins did not form helical structures. Instead, together with other morphogenetic factors, they assembled into discrete patches that moved processively along peripheral tracks perpendicular to the cell axis. Patch motility was largely powered by cell wall synthesis, and MreB polymers restricted diffusion of patch components in the membrane and oriented patch motion.
NASA Astrophysics Data System (ADS)
Lee, Seihyoung; Lim, Kwon-Seob; Lee, Jong Jin; Kang, Hyun Seo
2009-10-01
The optical wavelength-division-multiplex filter for bidirectional optical subassembly (BOSA) is embedded to the fiber core, which results in simplicity of the BOSA module. The fiber cladding is 45-deg angle polished to receive a downstream signal. The core is etched by a femtosecond laser to have a normal core facet and to transmit an upstream signal. The downstream signal, which is core mode, is coupled to the cladding mode by the long-period fiber grating and then detected by a photodiode by means of the total internal reflection effect at the 45-deg angle polished cladding facet. The measured transmitted and received coupling efficiencies are 27.3 and 43.8%, respectively.
A Klein-tunneling transistor with ballistic graphene
NASA Astrophysics Data System (ADS)
Wilmart, Quentin; Berrada, Salim; Torrin, David; Nguyen, V. Hung; Fève, Gwendal; Berroir, Jean-Marc; Dollfus, Philippe; Plaçais, Bernard
2014-06-01
Today, the availability of high mobility graphene up to room temperature makes ballistic transport in nanodevices achievable. In particular, p-n-p transistors in the ballistic regime give access to Klein tunneling physics and allow the realization of devices exploiting the optics-like behavior of Dirac Fermions (DFs) as in the Veselago lens or the Fabry-Pérot cavity. Here we propose a Klein tunneling transistor based on the geometrical optics of DFs. We consider the case of a prismatic active region delimited by a triangular gate, where total internal reflection may occur, which leads to the tunable suppression of transistor transmission. We calculate the transmission and the current by means of scattering theory and the finite bias properties using non-equilibrium Green's function (NEGF) simulation.
NASA Astrophysics Data System (ADS)
Kishkovich, Oleg P.; Bolgov, Dennis; Goodwin, William
1999-06-01
In this paper, the authors discuss the requirements for chemical air filtration system used in conjunction with modern DUV photolithography equipment. Among the topics addressed are the scope of pollutants, their respective internal and external sources, and an overview of different types of filtration technologies currently in use. Key filtration parameters, including removal efficiency, service life, and spill protection capacity, are discussed and supported by actual data, reflection the total molecular base concentration in operational IC manufacturing facilities. The authors also describe a time-accelerated testing procedure for comparing and evaluating different filtration technologies and designs, and demonstrate how this three-day test procedure can reliably predict an effective filter service life up to ten years.
NASA Astrophysics Data System (ADS)
Ou, Jiemei; Yang, Yuzhao; Lin, Wensheng; Yuan, Zhongke; Gan, Lin; Lin, Xiaofeng; Chen, Xudong; Chen, Yujie
2015-03-01
We investigated the transitions of conformations and their effects on emission properties of poly[2-methoxy-5-(2'-ethyl-hexyloxy)-1,4-phenylene vinylene] (MEH-PPV) single molecules in PMMA matrix during thermal annealing process. Total internal reflection fluorescence microscopy measurements reveal the transformation from collapsed conformations to extended, highly ordered rod-like structures of MEH-PPV single molecules during thermal annealing. The blue shifts in the ensemble single molecule PL spectra support our hypnosis. The transition occurs as the annealing temperature exceeds 100 °C, implying that an annealing temperature near the glass transition temperature Tg of matrix is ideal for the control and optimization of blend polymer films.
Evaluation of constricted affect in chronic pain: an attempt using the Toronto Alexythymia Scale.
Millard, R W; Kinsler, B L
1992-09-01
The Toronto Alexythymia Scale (TAS) was applied as a potential measure of constricted affect among a sample of patients with chronic, non-malignant pain (n = 195). As previously demonstrated with non-clinical samples, the scale was found to possess moderate reliability with two principal internal factors. These factors seemed to reflect social introversion and a lack of proneness to fantasy. There was a moderate, negative association between them. The domain sampled by the TAS was apparently heterogeneous, with total scores showing no relationship to reported disability or pain intensity and a low relationship to reported distress. These results suggest potential limitations of the TAS and the alexythymia construct as means for evaluating constricted affect that accompanies chronic pain.
Simultaneous observation of chemomechanical coupling of a molecular motor.
Nishizaka, Takayuki; Hasimoto, Yuh; Masaike, Tomoko
2011-01-01
F(1)-ATPase is the smallest rotary molecular motor ever found. Unidirectional rotation of the γ-shaft is driven by precisely coordinated sequential ATP hydrolysis reactions in three catalytic sites arranged 120° apart in the cylinder. Single-molecule observation allows us to directly watch the rotation of the shaft using micron-sized plastic beads. Additionally, an advanced version of "total internal reflection fluorescence microscope (TIRFM)" enables us to detect binding and release of energy currency through fluorescently labeled ATP. In this chapter, we describe how to set up the system for simultaneous observation of these two critical events. This specialized optical setup is applicable to a variety of research, not only molecular motors but also other single-molecule topics.
Aoyagi, Kyota; Ohara-Imaizumi, Mica; Nishiwaki, Chiyono; Nakamichi, Yoko; Nagamatsu, Shinya
2009-01-01
To investigate the different effects between sulfonylurea (SU) and glinide drugs in insulin secretion, pancreatic β-cells were repeatedly stimulated with SU (glimepiride) or glinide (mitiglinide). Total internal reflection fluorescent (TIRF) microscopy revealed that secondary stimulation with glimepiride, but not glucose and mitiglinide, failed to evoke fusions of insulin granules although primary stimulation with glucose, glimepiride, and mitiglinide induced equivalent numbers of exocytotic responses. Glimepiride, but not glucose and mitiglinide, induced abnormally sustained [Ca2+]i elevations and reductions of docked insulin granules on the plasma membrane. Our data suggest that the effect of glinide on insulin secretory mechanisms is similar to that of glucose. PMID:20069052
Lasing properties of polymerized chiral nematic Bragg onion microlasers.
Humar, Matjaž; Araoka, Fumito; Takezoe, Hideo; Muševič, Igor
2016-08-22
Dye doped photocurable cholesteric liquid crystal was used to produce solid Bragg onion omnidirectional lasers. The lasers were produced by dispersing and polymerizing chiral nematic LC with parallel surface anchoring of LC molecules at the interface, extracted and transferred into another medium. Lasing characteristics were studied in carrier medium with different refractive index. The lasing in spherical cholesteric liquid crystal was attributed to two mechanisms, photonic bandedge lasing and lasing of whispering-gallery modes. The latter can be suppressed by using a higher index carrier fluid to prevent total internal reflection on the interface of the spheres. Pulse-to-pulse stability and threshold characteristics were also studied and compared to non-polymerized lasers. The polymerization process greatly increases the lasing stability.
Hemorrhagic Fever Virus Budding Studies.
Harty, Ronald N
2018-01-01
Independent expression of the VP40 or Z matrix proteins of filoviruses (marburgviruses and ebolaviruses) and arenaviruses (Lassa fever and Junín), respectively, gives rise to the production and release of virus-like particles (VLPs) that are morphologically identical to infectious virions. We can detect and quantify VLP production and egress in mammalian cells by transient transfection, SDS-PAGE, Western blotting, and live cell imaging techniques such as total internal reflection fluorescence (TIRF) microscopy. Since the VLP budding assay accurately mimics budding of infectious virus, this BSL-2 assay is safe and useful for the interrogation of both viral and host determinants required for budding and can be used as an initial screen to identify and validate small molecule inhibitors of virus release and spread.
A cell-free assay to determine the stoichiometry of plasma membrane proteins.
Trigo, Cesar; Vivar, Juan P; Gonzalez, Carlos B; Brauchi, Sebastian
2013-04-01
Plasma membrane receptors, transporters, and ion channel molecules are often found as oligomeric structures that participate in signaling cascades essential for cell survival. Different states of protein oligomerization may play a role in functional control and allosteric regulation. Stochastic GFP-photobleaching (SGP) has emerged as an affordable and simple method to determine the stoichiometry of proteins at the plasma membrane. This non-invasive optical approach can be useful for total internal reflection of fluorescence microscopy (TIRFM), where signal-to-noise ratio is very high at the plasma membrane. Here, we report an alternative methodology implemented on a standard laser scanning confocal microscope (LSCM). The simplicity of our method will allow for its implementation in any epifluorescence microscope of choice.
ERIC Educational Resources Information Center
Reis, Jehnie I.
2010-01-01
In the 1920s, French scholars and bureaucrats created the Cite Universitaire in Paris. The institution housed university students from around the world. The Cite founders formulated a model for the Cite that reflected ideological concerns in interwar Europe with a focus on pacifism, international education and cultural internationalism. The…
Interns reflect: the effect of formative assessment with feedback during pre-internship
McKenzie, Susan; Burgess, Annette; Mellis, Craig
2017-01-01
Background It is widely known that the opportunity for medical students to be observed and to receive feedback on their procedural skills performance is variable in the senior years. To address this problem, we provided our Pre-Intern (PrInt) students with “one-to-one” formative feedback on their ability to perform urethral catheterization (U/C) and hypothesized that their future practice of U/C as interns would benefit. This study sought to evaluate the performance and practice of interns in U/C 4–5 months after having received feedback on their performance of U/C as PrInt students. Methods Between 2013 and 2014, two cohorts of interns, (total n=66) who had received recent formative feedback on their U/C performance as PrInt students at Central Clinical School, were invited to complete an anonymous survey. The survey contained nine closed unvalidated questions and one open-ended question, designed to allow interns to report on their current practice of U/C. Results Forty-one out of 66 interns (62%) completed the survey. Thirty-five out of 41 respondents (85%) reported that the assessment with feedback during their PrInt term was beneficial to their practice. Thirty of 41 (73%) reported being confident to perform U/C independently. Eleven out of 41 respondents (27%) reported that they had received additional training at intern orientation. Nine of the 11 interns (82%) reported that they had a small, but a significant, increase in confidence to perform U/C when compared with the 30 of the 41 respondents (73%) who had not (p=0.03). Conclusion Our results substantiate our hypothesis that further education by assessment with feedback in U/C during PrInt was of benefit to interns’ performance. Additional educational reinforcement in U/C during intern orientation further improved intern confidence. Our results indicate that extra pre- and post-graduation procedural skills training, with feedback, should be universal. PMID:28138270
Executive reflects on progress in the oil and gas industry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Popov, S.
1997-08-01
This paper reflects on the UK oil and gas industry`s international globalization and progress from the perspective of a UK industry executive. Sir Ian Wood, managing director of John Wood Group plc, outlined past and future industry developments during a 1997 Offshore Technology Conference speech. He concludes that the UK supply and service industry is now fully involved in the international arena, and hopes to play a significant role in the exciting oil and gas developments in the Gulf of Mexico and frontiers worldwide.
The Second Annual International Space University Alumni Conference
NASA Technical Reports Server (NTRS)
Johnson, Les (Compiler); Robinson, Paul A. (Compiler)
1994-01-01
The papers presented at the conference reflect the multidisciplinary nature of the International Space University (ISU) and its alumni. The first papers presented hold special relevance to the design projects, and cover such topics as lunar-based astronomical instrumentation, solar lunar power generation, habitation on the moon, and the legal issues governing multinational astronauts conducting research in space. The next set of papers cover various technical issues such as project success assessment, satellite networks and space station dynamics, thus reflecting the diverse backgrounds of the ISU alumni.
NASA Technical Reports Server (NTRS)
Mookherji, T.
1976-01-01
Outgassing, deposition, and desorption kinetics of silicone compounds, are examined as examples of optical surface contaminants of spacecraft windows. Their behavior in a space environment after exposure to ultraviolet radiation is also examined. The use of internal reflection spectroscopy is shown to provide a viable means of real-time, in-situ identification of contaminants of orbiting spacecraft. The instrumental techniques are proposed as the basis of further investigations and the development of flight hardware.
Method of making a modular off-axis solar concentrator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Plesniak, Adam P.; Hall, John C.
A method of making a solar concentrator may include forming a receiving wall having an elongated wall, a first side wall and a second side wall; attaching the first side wall and the second side wall to a reflecting wall to form a housing having an internal volume with an opening; forming a lip on the receiving wall and the reflecting wall; attaching a cover to the receiving wall and the reflecting wall at the lip to seal the opening into the internal volume, thereby creating a rigid structure; and mounting at least one receiver having at least one photovoltaicmore » cell on the elongated wall to receive solar radiation entering the housing and reflected by the receiving wall, the receiver having an axis parallel with a surface normal of the photovoltaic cell, such that the axis is disposed at a non-zero angle relative to the vertical axis of the opening.« less
Microwave based civil structure inspection device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sohns, C.W.; Bible, D.W.
1994-06-01
A microwave based ``wall probe`` has been developed which is capable of nondestructive evaluation of architectural structures. By using microwaves in the 8 to 12 GHz range this probing instrument can detect subsurface characteristics through concrete, brick, wood or other building materials to depths in excess of 12 inches. The instrument interrogates a structure from a single side by transmitting a microwave signal into the surface at some angle of incidence and receiving the reflected signal some distance away on the same side of the structure. The transmitted signal is partially reflected at each internal boundary of different dielectric constant,more » giving a composite reflection which contains information from each internal layer. The reflected composite signal is compared in phase and amplitude to the transmitted signal and that reading is considered the ``signature`` of the structure under test. Computer algorithms analyze the signature for recognizable features and nonstandard construction.« less
Perspectives on Numeracy: Reflections from International Assessments
ERIC Educational Resources Information Center
Tout, Dave; Gal, Iddo
2015-01-01
This paper examines perspectives regarding the mathematical skills expected of adults and school graduates, comparing ideas developed as part of two major multinational comparative assessments of skills: the Programme for International Student Assessment and the Programme for International Assessment of Adult Competencies (also known as the OECD…
76 FR 76619 - International Mail: New Prices and Fee Changes-Mailing Services
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-08
... POSTAL SERVICE 39 CFR Part 20 International Mail: New Prices and Fee Changes--Mailing Services... Individual Country Listings (ICLs) to reflect price adjustments for First-Class Mail International[supreg... mailing services price adjustments with the Postal Regulatory Commission (PRC), effective on January 22...
75 FR 5351 - Proposed Revisions to Accounting Guide for LSC Recipients
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-02
... elements of an adequate accounting and financial reporting system, including the use of specific internal... checklist of accounting procedures and internal controls. The proposed revisions update the checklist to... accounting procedures and internal controls to reflect current best practices; (7) updated and new references...
Factor Analysis of Intern Effectiveness
ERIC Educational Resources Information Center
Womack, Sid T.; Hannah, Shellie Louise; Bell, Columbus David
2012-01-01
Four factors in teaching intern effectiveness, as measured by a Praxis III-similar instrument, were found among observational data of teaching interns during the 2010 spring semester. Those factors were lesson planning, teacher/student reflection, fairness & safe environment, and professionalism/efficacy. This factor analysis was as much of a…
Xia, Xianping; Wang, Yun; Cai, Shuizhou; Xie, Changsheng; Zhu, Changhong
2009-01-01
Copper/low-density polyethylene (Cu/LDPE) nanocomposite intrauterine device (IUD) is an implanted medicinal device that must be sterilized before use. Sterilization processes act either chemically or physically, leading to a lethal change in the structure or function of organic macromolecules in microorganisms. Given the nature of their action, sterilization might also attack the macromolecules of polymers by the same mechanisms, resulting in changes in surface functional groups and in the internal structure of the polymer. If sterilization leads to changes in surface functional groups and in the internal structure of the LDPE matrix, which will influence the mechanical property and cupric ions release rate of novel Cu/LDPE nanocomposite IUDs, potential clinical application will be limited. Therefore, it is necessary to study the influence of ethylene oxide sterilization on the potential clinical application of novel Cu/LDPE nanocomposite IUDs. The influence of ethylene oxide sterilization on the internal structure, surface functional groups, mechanical property and cupric ions release rate of novel Cu/LDPE nanocomposite IUDs was studied using differential scanning calorimetry, attenuated total reflection Fourier transform infrared spectroscopy, tensile testing and absorbance measurement. Ethylene oxide sterilization did not have any influence on the internal structure, surface functional groups, mechanical property and cupric ions release rate of novel Cu/LDPE nanocomposite intrauterine devices. Ethylene oxide sterilization will not affect the potential application of novel Cu/LDPE nanocomposite IUDs.
Publications - GMC 126 | Alaska Division of Geological & Geophysical
DGGS GMC 126 Publication Details Title: Total organic carbon, rock-eval pyrolysis, and vitrinite Reference Unknown, 1989, Total organic carbon, rock-eval pyrolysis, and vitrinite reflectance data of Organic Carbon; Vitrinite Reflectance Top of Page Department of Natural Resources, Division of Geological
Publications - GMC 143 | Alaska Division of Geological & Geophysical
DGGS GMC 143 Publication Details Title: Total organic carbon, rock-eval pyrolysis, and vitrinite Reference Unknown, 1989, Total organic carbon, rock-eval pyrolysis, and vitrinite reflectance data of Organic Carbon; Vitrinite Reflectance Top of Page Department of Natural Resources, Division of Geological
Publications - GMC 66 | Alaska Division of Geological & Geophysical Surveys
DGGS GMC 66 Publication Details Title: Total organic carbon, rock-eval pyrolysis, and vitrinite Reference Unknown, 1987, Total organic carbon, rock-eval pyrolysis, and vitrinite reflectance geochemical Organic Carbon; Vitrinite Reflectance Top of Page Department of Natural Resources, Division of Geological
Publications - GMC 142 | Alaska Division of Geological & Geophysical
DGGS GMC 142 Publication Details Title: Total organic carbon, rock-eval pyrolysis, and vitrinite Reference Unknown, 1989, Total organic carbon, rock-eval pyrolysis, and vitrinite reflectance data of Organic Carbon; Vitrinite Reflectance Top of Page Department of Natural Resources, Division of Geological
NASA Technical Reports Server (NTRS)
Khodadad, Christina L.; Birmele, Michele N.; Roman, Monsi; Hummerick, Mary E.; Smith, David J.; Wheeler, Raymond M.
2015-01-01
Previous research has shown that microorganisms and potential human pathogens have been detected on the International Space Station (ISS). The potential to introduce new microorganisms occurs with every exchange of crew or addition of equipment or supplies. Previous research has shown that microorganisms introduced to the ISS are readily transferred between crew and subsystems and back (i.e. ECLSS, environmental control and life support systems). Current microbial characterization methods require enrichment of microorganisms and a 48-hour incubation time. This increases the microbial load while detecting a limited number of microorganisms. The culture based method detects approximately 1-10% of the total organisms present and provides no identification, To identify and enumerate ISS samples requires that samples to be returned to Earth for complete analysis. Therefore, a more expedient, low-cost, in-flight method of microbial detection, identification, and enumeration is warranted. The RAZOR EX, a ruggedized, commercial off the shelf, real-time PCR field instrument was tested for its ability to detect microorganism at low concentrations within one hour. Escherichia coli, Salmonella enterica Typhimurium, and Pseudomonas aeruginosa were detected at low levels using real-time DNA amplification. Total heterotrophic counts could also be detected using a 16S gene marker that can identify up to 98% of all bacteria. To reflect viable cells found in the samples, RNA was also detectable using a modified, single-step reverse transcription reaction.