Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-10
...-or-Cancel orders, and (3) maintain a ratio of executed liquidity adding volume-to-total volume of... of CADV, ratio of cancelled orders to total orders and ratio of executed liquidity adding volume-to... ratio of executed liquidity adding volume to total volume of greater than 80%, which is the same ratio...
Fluid intake patterns: an epidemiological study among children and adolescents in Brazil
2012-01-01
Background Energy from liquids is one of the most important factors that could impact on the high prevalence of children and adolescents obesity around the world. There are few data on the liquid consumption in Brazil. The aim of this study is to evaluate the volume and quality of liquids consumed by Brazilian children and adolescents and to determine the proportion of their daily energy intake composed of liquids. Methods A multicenter study was conducted in five Brazilian cities; the study included 831 participants between 3 and 17 years of age. A four-day dietary record specific to fluids was completed for each individual, and the volume of and Kcal from liquid intake were evaluated. The average number of Kcal in each beverage was determined based on label information, and the daily energy intake data from liquids were compared with the recommendations of the National Health Surveillance Agency (Agência Nacional de Vigilância Sanitária– ANVISA), the Brazilian food regulation authority, according to each subject’s age. Results As the children aged, the volume of carbonated beverages that they consumed increased significantly, and their milk intake decreased significantly. For children between the ages of 3 and 10, milk and dairy products contributed the greatest daily number of Kcal from liquids. Sugar sweetened beverages which included carbonated beverages, nectars and artificial beverages, accounted for 37% and 45% of the total Kcal from liquid intake in the 3- to 6-year-old and 7- to 10- year-old groups, respectively. Among adolescents (participants 11- to 17- years old), most of the energy intake from liquids came from carbonated beverages, which accounted for an average of 207 kcal/day in this group (42% of their total energy intake from liquids). Health professionals should be attentive to the excessive consumption of sugar sweetened beverages in children and adolescents. The movement toward healthier dietary patterns at the individual and population levels may help to improve programs for preventing overweight and obesity in children and adolescents. Conclusion From childhood to adolescence the daily volume of liquid ingested increased reaching a total of 2.0 liters on average. Of this volume, the daily volume of milk ingested decreased while the carbonated drinks, sweetened, nectars and artificial beverages increased significantly. The proportion of water remained constant in about 1/3 of the total volume. From 3 to 17 years of age the energy intake from carbonated beverages increased by about 20%. The carbonated drinks on average corresponded to a tenth of the daily requirements of energy of adolescents. PMID:23167254
A prototype of volume-controlled tidal liquid ventilator using independent piston pumps.
Robert, Raymond; Micheau, Philippe; Cyr, Stéphane; Lesur, Olivier; Praud, Jean-Paul; Walti, Hervé
2006-01-01
Liquid ventilation using perfluorochemicals (PFC) offers clear theoretical advantages over gas ventilation, such as decreased lung damage, recruitment of collapsed lung regions, and lavage of inflammatory debris. We present a total liquid ventilator designed to ventilate patients with completely filled lungs with a tidal volume of PFC liquid. The two independent piston pumps are volume controlled and pressure limited. Measurable pumping errors are corrected by a programmed supervisor module, which modifies the inserted or withdrawn volume. Pump independence also allows easy functional residual capacity modifications during ventilation. The bubble gas exchanger is divided into two sections such that the PFC exiting the lungs is not in contact with the PFC entering the lungs. The heating system is incorporated into the metallic base of the gas exchanger, and a heat-sink-type condenser is placed on top of the exchanger to retrieve PFC vapors. The prototype was tested on 5 healthy term newborn lambs (<5 days old). The results demonstrate the efficiency and safety of the prototype in maintaining adequate gas exchange, normal acido-basis equilibrium, and cardiovascular stability during a short, 2-hour total liquid ventilator. Airway pressure, lung volume, and ventilation scheme were maintained in the targeted range.
NASA Technical Reports Server (NTRS)
Patzek, T. W.; Scriven, L. E.
1982-01-01
The Young-Laplace equation is solved for three-dimensional menisci between crossed cylinders, with either the contact line fixed or the contact angle prescribed, by means of the Galerkin/finite element method. Shapes are computed, and with them the practically important quantities: drop volume, wetted area, capillary pressure force, surface tension force, and the total force exerted by the drop on each cylinder. The results show that total capillary force between cylinders increases with decreasing contact angle, i.e. with better wetting. Capillary force is also increases with decreasing drop volume, approaching an asymptotic limit. However, the wetted area on each cylinder decreases with decreasing drop volume, which raises the question of the optimum drop volume to strive for, when permanent bonding is sought from solidified liquid. For then the strength of the bond is likely to depend upon the area of contact, which is the wetted area when the bonding agent was introduced in liquid form.
Tuzen, Mustafa; Pekiner, Ozlem Zeynep
2015-12-01
A rapid and environmentally friendly ultrasound assisted ionic liquid dispersive liquid liquid microextraction (USA-IL-DLLME) was developed for the speciation of inorganic selenium in beverages and total selenium in food samples by using graphite furnace atomic absorption spectrometry. Some analytical parameters including pH, amount of complexing agent, extraction time, volume of ionic liquid, sample volume, etc. were optimized. Matrix effects were also investigated. Enhancement factor (EF) and limit of detection (LOD) for Se(IV) were found to be 150 and 12 ng L(-1), respectively. The relative standard deviation (RSD) was found 4.2%. The accuracy of the method was confirmed with analysis of LGC 6010 Hard drinking water and NIST SRM 1573a Tomato leaves standard reference materials. Optimized method was applied to ice tea, soda and mineral water for the speciation of Se(IV) and Se(VI) and some food samples including beer, cow's milk, red wine, mixed fruit juice, date, apple, orange, grapefruit, egg and honey for the determination of total selenium. Copyright © 2015 Elsevier Ltd. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-07-01
... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels for Petroleum Liquids for..., reservoir, or container used for the storage of petroleum liquids, but does not include: (1) Pressure... tanks if the total volume of petroleum liquids added to and taken from a tank annually does not exceed...
Code of Federal Regulations, 2014 CFR
2014-07-01
... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels for Petroleum Liquids for..., reservoir, or container used for the storage of petroleum liquids, but does not include: (1) Pressure... tanks if the total volume of petroleum liquids added to and taken from a tank annually does not exceed...
Code of Federal Regulations, 2012 CFR
2012-07-01
... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels for Petroleum Liquids for..., reservoir, or container used for the storage of petroleum liquids, but does not include: (1) Pressure... tanks if the total volume of petroleum liquids added to and taken from a tank annually does not exceed...
Code of Federal Regulations, 2013 CFR
2013-07-01
... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels for Petroleum Liquids for..., reservoir, or container used for the storage of petroleum liquids, but does not include: (1) Pressure... tanks if the total volume of petroleum liquids added to and taken from a tank annually does not exceed...
Code of Federal Regulations, 2010 CFR
2010-07-01
... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels for Petroleum Liquids for..., reservoir, or container used for the storage of petroleum liquids, but does not include: (1) Pressure... tanks if the total volume of petroleum liquids added to and taken from a tank annually does not exceed...
40 CFR 60.433 - Performance test and compliance provisions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... indicating the cumulative liquid volumes used at each affected facility; or (ii) Segregated storage tanks for... related coatings measured as used by volume with different amounts of VOC content or different densities. n is the total number of raw inks and related coatings measured as used by volume with different...
Magnetic Resonance Imaging Quantification of Fasted State Colonic Liquid Pockets in Healthy Humans.
Murray, Kathryn; Hoad, Caroline L; Mudie, Deanna M; Wright, Jeff; Heissam, Khaled; Abrehart, Nichola; Pritchard, Susan E; Al Atwah, Salem; Gowland, Penny A; Garnett, Martin C; Amidon, Gregory E; Spiller, Robin C; Amidon, Gordon L; Marciani, Luca
2017-08-07
The rate and extent of drug dissolution and absorption from solid oral dosage forms is highly dependent on the volume of liquid in the gastrointestinal tract (GIT). However, little is known about the time course of GIT liquid volumes after drinking a glass of water (8 oz), particularly in the colon, which is a targeted site for both locally and systemically acting drug products. Previous magnetic resonance imaging (MRI) studies offered novel insights on GIT liquid distribution in fasted humans in the stomach and small intestine, and showed that freely mobile liquid in the intestine collects in fairly distinct regions or "pockets". Based on this previous pilot data, we hypothesized that (1) it is possible to quantify the time course of the volume and number of liquid pockets in the undisturbed colon of fasted healthy humans following ingestion of 240 mL, using noninvasive MRI methods; (2) the amount of freely mobile water in the fasted human colon is of the order of only a few milliliters. Twelve healthy volunteers fasted overnight and underwent fasted abdominal MRI scans before drinking 240 mL (∼8 fluid ounces) of water. After ingesting the water they were scanned at frequent intervals for 2 h. The images were processed to quantify freely mobile water in the total and regional colon: ascending, transverse, and descending. The fasted colon contained (mean ± SEM) 11 ± 5 pockets of resting liquid with a total volume of 2 ± 1 mL (average). The colonic fluid peaked at 7 ± 4 mL 30 min after the water drink. This peak fluid was distributed in 17 ± 7 separate liquid pockets in the colon. The regional analysis showed that pockets of free fluid were found primarily in the ascending colon. The interindividual variability was very high; the subjects showed a range of number of colonic fluid pockets from 0 to 89 and total colonic freely mobile fluid volume from 0 to 49 mL. This is the first study measuring the time course of the number, regional location, and volume of pockets of freely mobile liquid in the undisturbed colon of fasted humans after ingestion of a glass of water. Novel insights into the colonic fluid environment will be particularly relevant to improve our understanding and design of the in vivo performance of controlled release formulations targeted to the colon. The in vivo quantitative information presented here can be input into physiologically based mechanistic models of dissolution and absorption, and can be used in the design and set up of novel in vitro performance tools predictive of the in vivo environment.
A microprocessor-controlled tracheal insufflation-assisted total liquid ventilation system.
Parker, James Courtney; Sakla, Adel; Donovan, Francis M; Beam, David; Chekuri, Annu; Al-Khatib, Mohammad; Hamm, Charles R; Eyal, Fabien G
2009-09-01
A prototype time cycled, constant volume, closed circuit perfluorocarbon (PFC) total liquid ventilator system is described. The system utilizes microcontroller-driven display and master control boards, gear motor pumps, and three-way solenoid valves to direct flow. A constant tidal volume and functional residual capacity (FRC) are maintained with feedback control using end-expiratory and end-inspiratory stop-flow pressures. The system can also provide a unique continuous perfusion (bias flow, tracheal insufflation) through one lumen of a double-lumen endotracheal catheter to increase washout of dead space liquid. FRC and arterial blood gases were maintained during ventilation with Rimar 101 PFC over 2-3 h in normal piglets and piglets with simulated pulmonary edema induced by instillation of albumin solution. Addition of tracheal insufflation flow significantly improved the blood gases and enhanced clearance of instilled albumin solution during simulated edema.
30 CFR 250.1202 - Liquid hydrocarbon measurement.
Code of Federal Regulations, 2014 CFR
2014-07-01
...); when obtaining net standard volume and associated measurement parameters; and (4) When requested by the Regional Supervisor, provide the pipeline (retrograde) condensate volumes as allocated to the individual... nonreset totalizer; (ii) A calibrated mechanical displacement (pipe) prover, master meter, or tank prover...
30 CFR 250.1202 - Liquid hydrocarbon measurement.
Code of Federal Regulations, 2013 CFR
2013-07-01
...); when obtaining net standard volume and associated measurement parameters; and (4) When requested by the Regional Supervisor, provide the pipeline (retrograde) condensate volumes as allocated to the individual... nonreset totalizer; (ii) A calibrated mechanical displacement (pipe) prover, master meter, or tank prover...
30 CFR 250.1202 - Liquid hydrocarbon measurement.
Code of Federal Regulations, 2012 CFR
2012-07-01
...); when obtaining net standard volume and associated measurement parameters; and (4) When requested by the Regional Supervisor, provide the pipeline (retrograde) condensate volumes as allocated to the individual... nonreset totalizer; (ii) A calibrated mechanical displacement (pipe) prover, master meter, or tank prover...
Determination of void volume in normal phase liquid chromatography.
Jiang, Ping; Wu, Di; Lucy, Charles A
2014-01-10
Void volume is an important fundamental parameter in chromatography. Little prior discussion has focused on the determination of void volume in normal phase liquid chromatography (NPLC). Various methods to estimate the total void volume are compared: pycnometry; minor disturbance method based on injection of weak solvent; tracer pulse method; hold-up volume based on unretained compounds; and accessible volume based on Martin's rule and its descendants. These are applied to NPLC on silica, RingSep and DNAP columns. Pycnometry provides a theoretically maximum value for the total void volume and should be performed at least once for each new column. However, pycnometry does not reflect the volume of adsorbed strong solvent on the stationary phase, and so only yields an accurate void volume for weaker mobile phase conditions. 1,3,5-Tri-t-butyl benzene (TTBB) results in hold-up volumes that are convenient measures of the void volume for all eluent conditions on charge-transfer columns (RingSep and DNAP), but is weakly retained under weak eluent conditions on silica. Injection of the weak mobile phase component (hexane) may be used to determine void volume, but care must be exercised to select the appropriate disturbance feature. Accessible volumes, that are determined using a homologous series, are always biased low, and are not recommended as a measure of the void volume. Copyright © 2013 Elsevier B.V. All rights reserved.
Cardiopulmonary function and oxygen delivery during total liquid ventilation.
Tsagogiorgas, Charalambos; Alb, Markus; Herrmann, Peter; Quintel, Michael; Meinhardt, Juergen P
2011-10-01
Total liquid ventilation (TLV) with perfluorocarbons has shown to improve cardiopulmonary function in the injured and immature lung; however there remains controversy over the normal lung. Hemodynamic effects of TLV in the normal lung currently remain undetermined. This study compared changes in cardiopulmonary and circulatory function caused by either liquid or gas tidal volume ventilation. In a prospective, controlled study, 12 non-injured anesthetized, adult New Zealand rabbits were primarily conventionally gas-ventilated (CGV). After instrumentation for continuous recording of arterial (AP), central venous (CVP), left artrial (LAP), pulmonary arterial pressures (PAP), and cardiac output (CO) animals were randomized into (1) CGV group and (2) TLV group. In the TLV group partial liquid ventilation was initiated with instillation of perfluoroctylbromide (12 ml/kg). After 15 min, TLV was established for 3 hr applying a volume-controlled, pressure-limited, time-cycled ventilation mode using a double-piston configured TLV. Controls (CGV) remained gas-ventilated throughout the experiment. During TLV, heart rate, CO, PAP, MAP, CVP, and LAP as well as derived hemodynamic variables, arterial and mixed venous blood gases, oxygen delivery, PVR, and SVR did not differ significantly compared to CGV. Liquid tidal volumes suitable for long-term TLV in non-injured rabbits do not significantly impair CO, blood pressure, and oxygen dynamics when compared to CGV. Copyright © 2011 Wiley-Liss, Inc.
Elevated airway liquid volumes at birth: a potential cause of transient tachypnea of the newborn.
McGillick, Erin V; Lee, Katie; Yamaoka, Shigeo; Te Pas, Arjan B; Crossley, Kelly J; Wallace, Megan J; Kitchen, Marcus J; Lewis, Robert A; Kerr, Lauren T; DeKoninck, Philip; Dekker, Janneke; Thio, Marta; McDougall, Annie R A; Hooper, Stuart B
2017-11-01
Excessive liquid in airways and/or distal lung tissue may underpin the respiratory morbidity associated with transient tachypnea of the newborn (TTN). However, its effects on lung aeration and respiratory function following birth are unknown. We investigated the effect of elevated airway liquid volumes on newborn respiratory function. Near-term rabbit kittens (30 days gestation; term ~32 days) were delivered, had their lung liquid-drained, and either had no liquid replaced (control; n = 7) or 30 ml/kg of liquid re-added to the airways [liquid added (LA); n = 7]. Kittens were mechanically ventilated in a plethysmograph. Measures of chest and lung parameters, uniformity of lung aeration, and airway size were analyzed using phase contrast X-ray imaging. The maximum peak inflation pressure required to recruit a tidal volume of 8 ml/kg was significantly greater in LA compared with control kittens (35.0 ± 0.7 vs. 26.8 ± 0.4 cmH 2 O, P < 0.001). LA kittens required greater time to achieve lung aeration (106 ± 14 vs. 60 ± 6 inflations, P = 0.03) and had expanded chest walls, as evidenced by an increased total chest area (32 ± 9%, P < 0.0001), lung height (17 ± 6%, P = 0.02), and curvature of the diaphragm (19 ± 8%, P = 0.04). LA kittens had lower functional residual capacity during stepwise changes in positive end-expiratory pressures (5, 3, 0, and 5 cmH 2 0). Elevated lung liquid volumes had marked adverse effects on lung structure and function in the immediate neonatal period and reduced the ability of the lung to aerate efficiently. We speculate that elevated airway liquid volumes may underlie the initial morbidity in near-term babies with TTN after birth. NEW & NOTEWORTHY Transient tachypnea of the newborn reduces respiratory function in newborns and is thought to result due to elevated airway liquid volumes following birth. However, the effect of elevated airway liquid volumes on neonatal respiratory function is unknown. Using phase contrast X-ray imaging, we show that elevated airway liquid volumes have adverse effects on lung structure and function in the immediate newborn period, which may underlie the pathology of TTN in near-term babies after birth. Copyright © 2017 the American Physiological Society.
40 CFR 98.403 - Calculating GHG emissions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.403...). Fuel = Total annual volume of product “h” supplied (volume per year, in Mscf for natural gas and bbl... procedures below. (1) For natural gas that is received for redelivery to downstream gas transmission...
Effect of turning frequency and season on composting materials from swine high-rise facilities
USDA-ARS?s Scientific Manuscript database
Composting of swine manure has several advantages, liquid slurries are converted to solid, the total volume of material is reduced and the stabilized product is more easily transported off-site. Despite this, swine waste is generally stored, treated and applied in its liquid form. The high-rise fini...
Bloss, P; Werner, C
2000-06-01
We propose a simple model to describe pressure-time and pressure-volume curves for the free balloon (balloon in air) of balloon catheters, taking into account the dynamics of the inflation device. On the basis of our investigations of the flow rate-dependence of characteristic parameters of the pressure-time curves, the appropriateness of this simple model is demonstrated using a representative example. Basic considerations lead to the following assumptions: (1) the flow within the shaft of the catheter is laminar, and (ii) the volume decrease of the liquid used for inflation due to pressurization can be neglected if the liquid is carefully degassed prior to inflation, and if the total volume of the liquid in the system is less than 2 ml. Taking into account the dynamics of the inflation device used for pumping the liquid into the proximal end of the shaft during inflation, the inflation process can be subdivided into the following three phases: initial phase, filling phase and dilatation phase. For these three phases, the transformation of the time into the volume coordinates is given. On the basis of our model, the following parameters of the balloon catheter can be determined from a measured pressure-time curve: (1) the resistance to flow of the liquid through the shaft of the catheter and the resulting pressure drop across the shaft, (2) the residual volume and residual pressure of the balloon, and (3) the volume compliance of the balloon catheter with and without the inflation device.
NASA Technical Reports Server (NTRS)
Singh, Jag J.; Eftekhari, Abe; St.clair, Terry L.; Sprinkle, Danny R.
1991-01-01
Microstructural changes in Polyetherether-ketone (PEEK) films were investigated in the temperature ranges of 23 to -196 C, using Positron Lifetime Spectroscopy (PLS) technique. It was determined that the total free volume decreases by about 46 percent in amorphous PEEK samples and about 36 percent in semicrystalline PEEK samples when they are cooled down from room temperature to liquid nitrogen (LN2) temperature. If this trend in reduction in free volume with decreasing temperature continues, as expected, it is surmised that PEEK will be able to withstand cooling down to liquid hydrogen (LH2) temperature without any detrimental effect on its diffusivity for liquid hydrogen.
NASA Astrophysics Data System (ADS)
Dodd, Michael; Ferrante, Antonino
2017-11-01
Our objective is to perform DNS of finite-size droplets that are evaporating in isotropic turbulence. This requires fully resolving the process of momentum, heat, and mass transfer between the droplets and surrounding gas. We developed a combined volume-of-fluid (VOF) method and low-Mach-number approach to simulate this flow. The two main novelties of the method are: (i) the VOF algorithm captures the motion of the liquid gas interface in the presence of mass transfer due to evaporation and condensation without requiring a projection step for the liquid velocity, and (ii) the low-Mach-number approach allows for local volume changes caused by phase change while the total volume of the liquid-gas system is constant. The method is verified against an analytical solution for a Stefan flow problem, and the D2 law is verified for a single droplet in quiescent gas. We also demonstrate the schemes robustness when performing DNS of an evaporating droplet in forced isotropic turbulence.
Meinhardt, J P; Ashton, B A; Annich, G M; Quintel, M; Hirschl, R B
2003-05-30
To evaluate the influence of pump system and flow pattern on expiratory airway collapse (EAC) in total perfluorocarbon ventilation. - Prospective, controlled, randomized animal trial for determination of (1) post-mortem changes by repeated expiration procedures (EP) with a constant flow piston pump (PP) before and after sacrifice (n = 8 rabbits), (2) differences between pump systems by subjecting animals to both PP and roller pump (RP) circuits for expiration (n = 16 rabbits). EP were performed using a servo-controlled shut-off at airway pressures < 25 cm H subset 2O randomly with either pump at different flows. - Expired volumes before and after sacrifice were not significantly different. PP and RP revealed identical mean flows, while significantly more liquid was drained using PP (p<0.05). Increasing differences towards higher flow rates indicated profound flow pulsatility in RP. - (1) post-mortem changes in expired volumes are not significant, (2) EAC is related to flow rate and pump system; (3) relationship between expiratory flow rate and drainable liquid volume is linear inverse; (4) PP provides higher drainage than RP. - Expiratory airway collapse is related to flow rate and pump system, post mortem changes in expirable volumes are not significant. Relationship between expiratory flow rate and drainable liquid volume is linear inverse, piston pump expiration provides higher drainage volumes than roller pump expiration.
Catalytic two-stage coal liquefaction process having improved nitrogen removal
Comolli, Alfred G.
1991-01-01
A process for catalytic multi-stage hydrogenation and liquefaction of coal to produce high yields of low-boiling hydrocarbon liquids containing low concentrations of nitogen compounds. First stage catalytic reaction conditions are 700.degree.-800.degree. F. temperature, 1500-3500 psig hydrogen partial pressure, with the space velocity maintained in a critical range of 10-40 lb coal/hr ft.sup.3 catalyst settled volume. The first stage catalyst has 0.3-1.2 cc/gm total pore volume with at least 25% of the pore volume in pores having diameters of 200-2000 Angstroms. Second stage reaction conditions are 760.degree.-870.degree. F. temperature with space velocity exceeding that in the first stage reactor, so as to achieve increased hydrogenation yield of low-boiling hydrocarbon liquid products having at least 75% removal of nitrogen compounds from the coal-derived liquid products.
Pierson, Stephen A; Trujillo-Rodríguez, María J; Anderson, Jared L
2018-05-29
An ionic-liquid-based in situ dispersive liquid-liquid microextraction method coupled to headspace gas chromatography and mass spectrometry was developed for the rapid analysis of ultraviolet filters. The chemical structures of five ionic liquids were specifically designed to incorporate various functional groups for the favorable extraction of the target analytes. Extraction parameters including ionic liquid mass, molar ratio of ionic liquid to metathesis reagent, vortex time, ionic strength, pH, and total sample volume were studied and optimized. The effect of the headspace temperature and volume during the headspace sampling step was also evaluated to increase the sensitivity of the method. The optimized procedure is fast as it only required ∼7-10 min per extraction and allowed for multiple extractions to be performed simultaneously. In addition, the method exhibited high precision, good linearity, and low limits of detection for six ultraviolet filters in aqueous samples. The developed method was applied to both pool and lake water samples attaining acceptable relative recovery values. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Development and application of a double-piston configured, total-liquid ventilatory support device.
Meinhardt, J P; Quintel, M; Hirschl, R B
2000-05-01
Perfluorocarbon liquid ventilation has been shown to enhance pulmonary mechanics and gas exchange in the setting of respiratory failure. To optimize the total liquid ventilation process, we developed a volume-limited, time-cycled liquid ventilatory support, consisting of an electrically actuated, microprocessor-controlled, double-cylinder, piston pump with two separate limbs for active inspiration and expiration. Prospective, controlled, animal laboratory study, involving sequential application of conventional gas ventilation, partial ventilation (PLV), and total liquid ventilation (TLV). Research facility at a university medical center. A total of 12 normal adult New Zealand rabbits weighing 3.25+/-0.1 kg. Anesthestized rabbits were supported with gas ventilation for 30 mins (respiratory rate, 20 cycles/min; peak inspiratory pressure, 15 cm H2O; end-expiratory pressure, 5 cm H2O), then PLV was established with perflubron (12 mL/kg). After 15 mins, TLV was instituted (tidal volume, 18 mL/kg; respiratory rate, 7 cycles/min; inspiratory/expiratory ratio, 1:2 cycles/min). After 4 hrs of TLV, PLV was re-established. Of 12 animals, nine survived the 4-hr TLV period. During TLV, mean values +/- SEM were as follows: PaO2, 363+/-30 torr; PaCO2, 39+/-1.5 torr; pH, 7.39+/-0.01; static peak inspiratory pressure, 13.2+/-0.2 cm H2O; static endexpiratory pressure, 5.5+/-0.1 cm H2O. No significant changes were observed. When compared with gas ventilation and PLV, significant increases occurred in mean arterial pressure (62.4+/-3.5 torr vs. 74.0+/-1.2 torr) and central venous pressure (5.6+/-0.7 cm H2O vs. 7.8+/-0.2 cm H2O) (p < .05). Total liquid ventilation can be performed successfully utilizing piston pumps with active expiration. Considering the enhanced flow profiles, this device configuration provides advantages over others.
Wandrey, Craig J.; Schenk, Christopher J.; Klett, Timothy R.; Brownfield, Michael E.; Charpentier, Ronald R.; Cook, Troy A.; Pollastro, Richard M.; Tennyson, Marilyn E.
2013-01-01
The Cretaceous-Tertiary Composite Total Petroleum System coincident Taranaki Basin Assessment Unit was recently assessed for undiscovered technically recoverable oil, natural gas, and natural gas liquids resources as part of the U.S. Geological Survey (USGS) World Energy Resources Project, World Oil and Gas Assessment. Using a geology-based assessment methodology, the USGS estimated mean volumes of 487 million barrels of oil, 9.8 trillion cubic feet of gas, and 408 million barrels of natural gas liquids.
US crude oil, natural gas, and natural gas liquids reserves, 1992 annual report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-10-18
This report presents estimates of proved reserves of crude oil, natural gas, and natural gas liquids as of December 31, 1992, as well as production volumes for the United States, and selected States and State subdivisions for the year 1992. Estimates are presented for the following four categories of natural gas: total gas (wet after lease separation), its two major components (nonassociated and associated-dissolved gas), and total dry gas (wet gas adjusted for the removal of liquids at natural gas processing plants). In addition, two components of natural gas liquids, lease condensate and natural gas plant liquids, have their reservesmore » and production data presented. Also included is information on indicated additional crude oil reserves and crude oil, natural gas, and lease condensate reserves in nonproducing reservoirs. A discussion of notable oil and gas exploration and development activities during 1992 is provided.« less
Xue, Juan Qin; Liu, Ni Na; Li, Guo Ping; Dang, Long Tao
To solve the disposal problem of cyanide wastewater, removal of cyanide from wastewater using a water-in-oil emulsion type of emulsion liquid membrane (ELM) was studied in this work. Specifically, the effects of surfactant Span-80, carrier trioctylamine (TOA), stripping agent NaOH solution and the emulsion-to-external-phase-volume ratio on removal of cyanide were investigated. Removal of total cyanide was determined using the silver nitrate titration method. Regression analysis and optimization of the conditions were conducted using the Design-Expert software and response surface methodology (RSM). The actual cyanide removals and the removals predicted using RSM analysis were in close agreement, and the optimal conditions were determined to be as follows: the volume fraction of Span-80, 4% (v/v); the volume fraction of TOA, 4% (v/v); the concentration of NaOH, 1% (w/v); and the emulsion-to-external-phase volume ratio, 1:7. Under the optimum conditions, the removal of total cyanide was 95.07%, and the RSM predicted removal was 94.90%, with a small exception. The treatment of cyanide wastewater using an ELM is an effective technique for application in industry.
2013-10-23
compensate for overcounting due to numerical issues inherent in the tessellation.16 The shape of the coordination polyhedron was determined by the shape...work by Yang et al.21 The total volume can be determined by finding the volume of the convex polyhedron whose vertices are given by the centers of...atoms in the nearest-neighbor shell. In order to determine the volume of the atoms inside the clusters, the convex hull polyhedron is first segmented
[Human body composition during extended stay in microgravity].
Noskov, V B; Nichiporuk, I A; Vasilieva, G Yu; Smirnov, Yu I
2015-01-01
According to the Sprut-2 protocol, bio-impedancemetry of ISS cosmonauts was performed once a month and also before and after mission. Multiple non-invasive body measurements were carried out in 15 cosmonauts in real time. Relocation of extracellular liquid along the body axis led to its reduction in legs and, on the contrary, an increase in the abdomen. Volumes of total body liquid as well as intra- and extracellular liquids decreased in comparison with pre-flight levels. Lean body mass also became less in microgravity, whereas fat mass showed an increase.
A regulator for pressure-controlled total-liquid ventilation.
Robert, Raymond; Micheau, Philippe; Avoine, Olivier; Beaudry, Benoit; Beaulieu, Alexandre; Walti, Hervé
2010-09-01
Total-liquid ventilation (TLV) is an innovative experimental method of mechanical-assisted ventilation in which lungs are totally filled and then ventilated with a tidal volume of perfluorochemical liquid by using a dedicated liquid ventilator. Such a novel medical device must resemble other conventional ventilators: it must be able to conduct controlled-pressure ventilation. The objective was to design a robust controller to perform pressure-regulated expiratory flow and to implement it on our latest liquid-ventilator prototype (Inolivent-4). Numerical simulations, in vitro experiments, and in vivo experiments in five healthy term newborn lambs have demonstrated that it was efficient to generate expiratory flows while avoiding collapses. Moreover, the in vivo results have demonstrated that our liquid ventilator can maintain adequate gas exchange, normal acid-base equilibrium, and achieve greater minute ventilation, better oxygenation and CO2 extraction, while nearing flow limits. Hence, it is our suggestion to perform pressure-controlled ventilation during expiration with minute ventilation equal or superior to 140 mL x min(-1) x kg(-1) in order to ensure PaCO2 below 55 mmHg. From a clinician's point of view, pressure-controlled ventilation greatly simplifies the use of the liquid ventilator, which will certainly facilitate its introduction in intensive care units for clinical applications.
NASA Astrophysics Data System (ADS)
Liang, Dong; Zhang, Jin; Thanikhatla Govindaiah, Muniyogeshbabu; Tanguy, Laurent; Ernst, Andreas; Zengerle, Roland; Koltay, Peter
2014-09-01
In this article, a quantitative liquid volume measurement method for the sub-nanoliter range using a quartz crystal microbalance (QCM) is described and experimentally analyzed. The primary measurement device to determine the volume of small liquid droplets is a QCM sensor coated with a surface-attached hydrogel to improve the mechanical coupling of the liquid to the sensor surface. An experimental evaluation of measured volumes in the range of 3 nl to 15 nl in normal room conditions has been performed with three identical sensors prepared with a PDMAA-1%MaBP hydrogel coating with a thickness of 1.5 µm ± 0.12 µm. A linearity of R2 more than 0.87, an average coefficient of variation (CV) within one experimental run of 5.7%, a mean absolute relative bias of 5.5%, and a sensor-to-sensor variation of 6.3% have been experimentally determined. The feasibility of this method has also been experimentally proven for the picoliter volume range down to 200 pl, with an average CV of 5.3% and a mean absolute relative bias of 6.5%. Furthermore, a stability evaluation consisting of 10 experimental series with approximately 150 measurements over the course of one week has been performed. This evaluation showed that the experimental setup, although exhibiting highly consistent performance within one measurement run, is not yet reproducible enough for long-term and repeated use because of undefined swelling and crack formation in the hydrogel layer. The low reproducibility implies a relatively high expanded uncertainty, with k = 2 according to the JCGM ‘Evaluation of Measurement Data—Guide to the Expression of Uncertainty in Measurement’ (GUM) for the total measurement method of approximately 3.82 nl when measuring a 10 nl liquid droplet. Nevertheless, the QCM method as described here contributes to significant progress beyond the state-of-the-art that might allow new opportunities for precise measurement of sub-nanoliter liquid volumes.
Klett, T.R.; Schenk, Christopher J.; Wandrey, Craig J.; Charpentier, Ronald R.; Cook, Troy A.; Brownfield, Michael E.; Pitman, Janet K.; Pollastro, Richard M.
2012-01-01
Using a geology-based assessment methodology, the U.S. Geological Survey estimated volumes of undiscovered, technically recoverable, conventional petroleum resources for the Assam, Bombay, Cauvery, and Krishna–Godavari Provinces, South Asia. The estimated mean volumes are as follows: (1) Assam Province, 273 million barrels of crude oil, 1,559 billion cubic feet of natural gas, and 43 million barrels of natural gas liquids; (2) Bombay Province, 1,854 million barrels of crude oil, 15,417 billion cubic feet of natural gas, and 498 million barrels of natural gas liquids; (3) Cauvery Province, 941 million barrels of crude oil, 25,208 billion cubic feet of natural gas, and 654 million barrels of natural gas liquids; and (4) Krishna–Godavari Province, 466 million barrels of crude oil, 37,168 billion cubic feet of natural gas, and 484 million barrels of natural gas liquids. The totals for the four provinces are 3,534 million barrels of crude oil, 79,352 billion cubic feet of natural gas, and 1,679 million barrels of natural gas liquids.
U.S. crude oil, natural gas, and natural gas liquids reserves 1997 annual report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wood, John H.; Grape, Steven G.; Green, Rhonda S.
1998-12-01
This report presents estimates of proved reserves of crude oil, natural gas, and natural gas liquids as of December 31, 1997, as well as production volumes for the US and selected States and State subdivisions for the year 1997. Estimates are presented for the following four categories of natural gas: total gas (wet after lease separation), nonassociated gas and associated-dissolved gas (which are the two major types of wet natural gas), and total dry gas (wet gas adjusted for the removal of liquids at natural gas processing plants). In addition, reserve estimates for two types of natural gas liquids, leasemore » condensate and natural gas plant liquids, are presented. Also included is information on indicated additional crude oil reserves and crude oil, natural gas, and lease condensate reserves in nonproducing reservoirs. A discussion of notable oil and gas exploration and development activities during 1997 is provided. 21 figs., 16 tabs.« less
Fine-scale Horizontal Structure of Arctic Mixed-Phase Clouds.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rambukkange,M.; Verlinde, J.; Elorante, E.
2006-07-10
Recent in situ observations in stratiform clouds suggest that mixed phase regimes, here defined as limited cloud volumes containing both liquid and solid water, are constrained to narrow layers (order 100 m) separating all-liquid and fully glaciated volumes (Hallett and Viddaurre, 2005). The Department of Energy Atmospheric Radiation Measurement Program's (DOE-ARM, Ackerman and Stokes, 2003) North Slope of Alaska (NSA) ARM Climate Research Facility (ACRF) recently started collecting routine measurement of radar Doppler velocity power spectra from the Millimeter Cloud Radar (MMCR). Shupe et al. (2004) showed that Doppler spectra has potential to separate the contributions to the total reflectivitymore » of the liquid and solid water in the radar volume, and thus to investigate further Hallett and Viddaurre's findings. The Mixed-Phase Arctic Cloud Experiment (MPACE) was conducted along the NSA to investigate the properties of Arctic mixed phase clouds (Verlinde et al., 2006). We present surface based remote sensing data from MPACE to discuss the fine-scale structure of the mixed-phase clouds observed during this experiment.« less
Chiou, C.T.; Schmedding, D.W.; Manes, M.
2005-01-01
A volume-fraction-based solvent-water partition model for dilute solutes, in which the partition coefficient shows a dependence on solute molar volume (V??), is adapted to predict the octanol-water partition coefficient (K ow) from the liquid or supercooled-liquid solute water solubility (Sw), or vice versa. The established correlation is tested for a wide range of industrial compounds and pesticides (e.g., halogenated aliphatic hydrocarbons, alkylbenzenes, halogenated benzenes, ethers, esters, PAHs, PCBs, organochlorines, organophosphates, carbamates, and amidesureas-triazines), which comprise a total of 215 test compounds spanning about 10 orders of magnitude in Sw and 8.5 orders of magnitude in Kow. Except for phenols and alcohols, which require special considerations of the Kow data, the correlation predicts the Kow within 0.1 log units for most compounds, much independent of the compound type or the magnitude in K ow. With reliable Sw and V data for compounds of interest, the correlation provides an effective means for either predicting the unavailable log Kow values or verifying the reliability of the reported log Kow data. ?? 2005 American Chemical Society.
SU-E-I-79: Source Geometry Dependence of Gamma Well-Counter Measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, M; Belanger, A; Kijewski, M
Purpose: To determine the effect of liquid sample volume and geometry on counting efficiency in a gamma well-counter, and to assess the relative contributions of sample geometry and self-attenuation. Gamma wellcounters are standard equipment in clinical and preclinical studies, for measuring patient blood radioactivity and quantifying animal tissue uptake for tracer development and other purposes. Accurate measurements are crucial. Methods: Count rates were measured for aqueous solutions of 99m- Tc at four liquid volume values in a 1-cm-diam tube and at six volume values in a 2.2-cm-diam vial. Total activity was constant for all volumes, and data were corrected formore » decay. Count rates from a point source in air, supported by a filter paper, were measured at seven heights between 1.3 and 5.7 cm from the bottom of a tube. Results: Sample volume effects were larger for the tube than for the vial. For the tube, count efficiency relative to a 1-cc volume ranged from 1.05 at 0.05 cc to 0.84 at 3 cc. For the vial, relative count efficiency ranged from 1.02 at 0.05 cc to 0.87 at 15 cc. For the point source, count efficiency relative to 1.3 cm from the tube bottom ranged from 0.98 at 1.8 cm to 0.34 at 5.7 cm. The relative efficiency of a 3-cc liquid sample in a tube compared to a 1-cc sample is 0.84; the average relative efficiency for the solid sample in air between heights in the tube corresponding to the surfaces of those volumes (1.3 and 4.8 cm) is 0.81, implying that the major contribution to efficiency loss is geometry, rather than attenuation. Conclusion: Volume-dependent correction factors should be used for accurate quantitation radioactive of liquid samples. Solid samples should be positioned at the bottom of the tube for maximum count efficiency.« less
HOW DOES ADDING AND REMOVING LIQUID FROM SOCKET BLADDERS AFFECT RESIDUAL LIMB FLUID VOLUME?
Sanders, JE; Cagle, JC; Harrison, DS; Myers, TR; Allyn, KJ
2015-01-01
Adding and removing liquid from socket bladders is a means for people with limb loss to accommodate residual limb volume change. Nineteen people with trans-tibial amputation using their regular prosthetic socket fitted with fluid bladders on the inside socket surface underwent cycles of bladder liquid addition and removal. In each cycle, subjects sat, stood, and walked for 90s with bladder liquid added and then sat, stood, and walking for 90s again with the bladder liquid removed. The amount of bladder liquid added was increased in each cycle. Bioimpedance analysis was implemented to measure residual limb fluid volume. Results showed that the preferred bladder liquid volume was 16.8 mL (s.d.8.4), corresponding to 1.7% (s.d.0.8%) of the average socket volume between the bioimpedance voltage-sensing electrodes. Limb fluid volume driven out of the residual limb when bladder liquid was added was typically not recovered upon subsequent bladder liquid removal. Fifteen of nineteen subjects experienced a gradual limb fluid volume loss over the test session. Care should be taken when implementing adjustable socket technologies in people with limb amputation. Reducing socket volume may accentuate limb fluid volume loss. PMID:24203546
On the prediction of spray angle of liquid-liquid pintle injectors
NASA Astrophysics Data System (ADS)
Cheng, Peng; Li, Qinglian; Xu, Shun; Kang, Zhongtao
2017-09-01
The pintle injector is famous for its capability of deep throttling and low cost. However, the pintle injector has been seldom investigated. To get a good prediction of the spray angle of liquid-liquid pintle injectors, theoretical analysis, numerical simulations and experiments were conducted. Under the hypothesis of incompressible and inviscid flow, a spray angle formula was deduced from the continuity and momentum equations based on a control volume analysis. The formula was then validated by numerical and experimental data. The results indicates that both geometric and injection parameters affect the total momentum ratio (TMR) and then influence the spray angle formed by liquid-liquid pintle injectors. TMR is the pivotal non-dimensional number that dominates the spray angle. Compared with gas-gas pintle injectors, spray angle formed by liquid-liquid injectors is larger, which benefits from the local high pressure zone near the pintle wall caused by the impingement of radial and axial sheets.
High air volume to low liquid volume aerosol collector
Masquelier, Donald A.; Milanovich, Fred P.; Willeke, Klaus
2003-01-01
A high air volume to low liquid volume aerosol collector. A high volume flow of aerosol particles is drawn into an annular, centripetal slot in a collector which directs the aerosol flow into a small volume of liquid pool contained is a lower center section of the collector. The annular jet of air impinges into the liquid, imbedding initially airborne particles in the liquid. The liquid in the pool continuously circulates in the lower section of the collector by moving to the center line, then upwardly, and through assistance by a rotating deflector plate passes back into the liquid at the outer area adjacent the impinging air jet which passes upwardly through the liquid pool and through a hollow center of the collector, and is discharged via a side outlet opening. Any liquid droplets escaping with the effluent air are captured by a rotating mist eliminator and moved back toward the liquid pool. The collector includes a sensor assembly for determining, controlling, and maintaining the level of the liquid pool, and includes a lower centrally located valve assembly connected to a liquid reservoir and to an analyzer for analyzing the particles which are impinged into the liquid pool.
40 CFR 799.2155 - Commercial hexane.
Code of Federal Regulations, 2013 CFR
2013-07-01
... least 40 liquid volume percent n-hexane (CAS No. 110-54-3) and at least 5 liquid volume percent... contains at least 40 liquid volume percent but no more than 55 liquid volume percent n-hexane and no less... 40 Protection of Environment 33 2013-07-01 2013-07-01 false Commercial hexane. 799.2155 Section...
40 CFR 799.2155 - Commercial hexane.
Code of Federal Regulations, 2014 CFR
2014-07-01
... least 40 liquid volume percent n-hexane (CAS No. 110-54-3) and at least 5 liquid volume percent... contains at least 40 liquid volume percent but no more than 55 liquid volume percent n-hexane and no less... 40 Protection of Environment 32 2014-07-01 2014-07-01 false Commercial hexane. 799.2155 Section...
Wang, Hong-wu; Liu, Yan-qing; Wang, Yuan-hong
2011-07-01
To investigate the ultrasonic-assisted extract on of total flavonoids from leaves of the Artocarpus heterophyllus. Investigated the effects of ethanol concentration, extraction time, and liquid-solid ratio on flavonoids yield. A 17-run response surface design involving three factors at three levels was generated by the Design-Expert software and experimental data obtained were subjected to quadratic regression analysis to create a mathematical model describing flavonoids extraction. The optimum ultrasonic assisted extraction conditions were: ethanol volume fraction 69.4% and liquid-solid ratio of 22.6:1 for 32 min. Under these optimized conditions, the yield of flavonoids was 7.55 mg/g. The Box-Behnken design and response surface analysis can well optimize the ultrasonic-assisted extraction of total flavonoids from Artocarpus heterophyllus.
Foam imbibition in a Hele-Shaw cell via laminated microfluidic ``T-junction'' device
NASA Astrophysics Data System (ADS)
Parra, Dina; Ward, Thomas
2013-11-01
In this talk we analyze experimental results of a novel microfluidic ``T-junction'' device, made from laminated plastic, that is used to produce foam in porous media. The fluids, both Newtonian and non-Newtonian liquids and air, are driven using constant-static pressure fluid pumping. For the T-junction geometry studied there are novel observations with this type of pumping: 1) at low pressure ratios there is an increase in the liquid and total flow rates and 2) at higher pressure ratios there is a decrease in the liquid flow rate. To understand this phenomenon we visualize the drop production process near the T-junction. Furthermore, flow rates for the liquid and total volume are estimated by imbibing the foam into a Hele-Shaw cell. Foam is produced by using a mixture containing aqueous polyacrylamide of concentrations ranging from 0.01-0.10% by weight and several solution also containing a sodium-lauryl-sulfate (SLS) surfactant at concentrations ranging 0.01-0.1% by weight.
Shock melting and vaporization of metals.
NASA Technical Reports Server (NTRS)
Ahrens, T. J.
1972-01-01
The effect of initial porosity on shock induction of melting and vaporization is investigated for Ba, Sr, Li, Fe, Al, U, and Th. For the less compressible of these metals, it is found that for a given strong shock-generation system (explosive in contact, or flyer-plate impact) an optimum initial specific volume exists such that the total entropy production, and hence the amount of metal liquid or vapor, is a maximum. Initial volumes from 1.4 to 2.0 times crystal volumes, depending on the metal sample and shock-inducing system, will result in optimum post-shock entropies.
NASA Astrophysics Data System (ADS)
Gangopadhyay, A. K.; Kelton, K. F.
2018-05-01
Previous studies reported a number of anomalies when estimates of linear thermal expansion coefficients of metallic liquids and glasses from x-ray scattering experiments were compared with direct measurements of volume/length changes with temperature. In most cases, the first peak of the pair correlation function showed a contraction, while the structure factor showed an expansion, but both at rates much different from those expected from the direct volume measurements. In addition, the relationship between atomic volume and the characteristic lengths obtained from the structure factor from scattering experiments was found to have a fractional exponent instead of one equal to three, as expected from the Ehrenfest relation. This has led to the speculation that the atomic packing in liquids and glasses follow a fractal behavior. These issues are revisited in this study using more in-depth analysis of recent higher resolution data and some new ideas suggested in the literature. The main conclusion is that for metallic alloys, at least to a large extent, most of these anomalies arise from complicated interplays of the temperature dependences of the various partial structure factors, which contribute to the total intensities of the scattering peaks.
Inkjet Printing in Liquid Environments.
Zhang, Yanzhen; Li, Dege; Liu, Yonghong; Wittstock, Gunther
2018-05-28
Inkjet printing (IJP) is an old but still vivifying technique for flexible and cost-effective printing of various kinds of functional inks. Normally, IJP can only work in gaseous environments. Here, it is shown that traditional piezoelectric IJP can be performed in liquid environments with a totally different droplet dispensing and manipulating mechanism. With the same piezoelectric nozzle, the volume of the droplets printed in a carrier liquid can be thousands of times smaller than those printed in air. Therefore, this work demonstrates a working mode of traditional IJP with a highly improved resolution opening possibilities for novel applications of the IJP technique. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A method of measuring a molten metal liquid pool volume
Garcia, G.V.; Carlson, N.M., Donaldson, A.D.
1990-12-12
A method of measuring a molten metal liquid pool volume and in particular molten titanium liquid pools, including the steps of (a) generating an ultrasonic wave at the surface of the molten metal liquid pool, (b) shining a light on the surface of a molten metal liquid pool, (c) detecting a change in the frequency of light, (d) detecting an ultrasonic wave echo at the surface of the molten metal liquid pool, and (e) computing the volume of the molten metal liquid. 3 figs.
Method of measuring a liquid pool volume
Garcia, G.V.; Carlson, N.M.; Donaldson, A.D.
1991-03-19
A method of measuring a molten metal liquid pool volume and in particular molten titanium liquid pools is disclosed, including the steps of (a) generating an ultrasonic wave at the surface of the molten metal liquid pool, (b) shining a light on the surface of a molten metal liquid pool, (c) detecting a change in the frequency of light, (d) detecting an ultrasonic wave echo at the surface of the molten metal liquid pool, and (e) computing the volume of the molten metal liquid. 3 figures.
Method of measuring a liquid pool volume
Garcia, Gabe V.; Carlson, Nancy M.; Donaldson, Alan D.
1991-01-01
A method of measuring a molten metal liquid pool volume and in particular molten titanium liquid pools, including the steps of (a) generating an ultrasonic wave at the surface of the molten metal liquid pool, (b) shining a light on the surface of a molten metal liquid pool, (c) detecting a change in the frequency of light, (d) detecting an ultrasonic wave echo at the surface of the molten metal liquid pool, and (e) computing the volume of the molten metal liquid.
Wang, Xiaoxing; Hu, Xiaoyan; Song, Chunshan; ...
2017-09-27
As a part of a new approach to convert biomass to liquid fuels, we investigated the effects of alkali treatment on the property and performance of HZSM-5 for oligomerization of biomass-derived ethylene under atmospheric pressure. The characterization results showed that alkali treatment led to the increase in the total and mesopore volumes, but decrease in the surface area and micropore volume. Furthermore, when NaOH concentration was low (< 0.5 M), the ZSM-5 structure was largely preserved with the increase in the mesopores and acidity, while higher NaOH concentration can severely destroy the zeolite structure, resulting in a significant reduction inmore » the micropores and acidity. The ethylene oligomerization results showed that not only the ethylene conversion and the liquid yield increased, but also the catalyst stability was improved after proper NaOH treatment. Finally, we discussed the relationship between the structure and performance« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Xiaoxing; Hu, Xiaoyan; Song, Chunshan
As a part of a new approach to convert biomass to liquid fuels, we investigated the effects of alkali treatment on the property and performance of HZSM-5 for oligomerization of biomass-derived ethylene under atmospheric pressure. The characterization results showed that alkali treatment led to the increase in the total and mesopore volumes, but decrease in the surface area and micropore volume. Furthermore, when NaOH concentration was low (< 0.5 M), the ZSM-5 structure was largely preserved with the increase in the mesopores and acidity, while higher NaOH concentration can severely destroy the zeolite structure, resulting in a significant reduction inmore » the micropores and acidity. The ethylene oligomerization results showed that not only the ethylene conversion and the liquid yield increased, but also the catalyst stability was improved after proper NaOH treatment. Finally, we discussed the relationship between the structure and performance« less
Thermodynamic properties derived from the free volume model of liquids
NASA Technical Reports Server (NTRS)
Miller, R. I.
1974-01-01
An equation of state and expressions for the isothermal compressibility, thermal expansion coefficient, heat capacity, and entropy of liquids have been derived from the free volume model partition function suggested by Turnbull. The simple definition of the free volume is used, and it is assumed that the specific volume is directly related to the cube of the intermolecular separation by a proportionality factor which is found to be a function of temperature and pressure as well as specific volume. When values of the proportionality factor are calculated from experimental data for real liquids, it is found to be approximately constant over ranges of temperature and pressure which correspond to the dense liquid phase. This result provides a single-parameter method for calculating dense liquid thermodynamic properties and is consistent with the fact that the free volume model is designed to describe liquids near the solidification point.
Liquid volume monitoring based on ultrasonic sensor and Arduino microcontroller
NASA Astrophysics Data System (ADS)
Husni, M.; Siahaan, D. O.; Ciptaningtyas, H. T.; Studiawan, H.; Aliarham, Y. P.
2016-04-01
Incident of oil leakage and theft in oil tank often happens. To prevent it, the liquid volume insides the tank needs to be monitored continuously. Aim of the study is to calculate the liquid volume inside oil tank on any road condition and send the volume data and location data to the user. This research use some ultrasonic sensors (to monitor the fluid height), Bluetooth modules (to sent data from the sensors to the Arduino microcontroller), Arduino Microcontroller (to calculate the liquid volume), and also GPS/GPRS/GSM Shield module (to get location of vehicle and sent the data to the Server). The experimental results show that the accuracy rate of monitoring liquid volume inside tanker while the vehicle is in the flat road is 99.33% and the one while the vehicle is in the road with elevation angle is 84%. Thus, this system can be used to monitor the tanker position and the liquid volume in any road position continuously via web application to prevent illegal theft.
Downstream processing of antibodies: single-stage versus multi-stage aqueous two-phase extraction.
Rosa, P A J; Azevedo, A M; Ferreira, I F; Sommerfeld, S; Bäcker, W; Aires-Barros, M R
2009-12-11
Single-stage and multi-stage strategies have been evaluated and compared for the purification of human antibodies using liquid-liquid extraction in aqueous two-phase systems (ATPSs) composed of polyethylene glycol 3350 (PEG 3350), dextran, and triethylene glycol diglutaric acid (TEG-COOH). The performance of single-stage extraction systems was firstly investigated by studying the effect of pH, TEG-COOH concentration and volume ratio on the partitioning of the different components of a Chinese hamster ovary (CHO) cells supernatant. It was observed that lower pH values and high TEG-COOH concentrations favoured the selective extraction of human immunoglobulin G (IgG) to the PEG-rich phase. Higher recovery yields, purities and percentage of contaminants removal were always achieved in the presence of the ligand, TEG-COOH. The extraction of IgG could be enhanced using higher volume ratios, however with a significant decrease in both purity and percentage of contaminants removal. The best single-stage extraction conditions were achieved for an ATPS containing 1.3% (w/w) TEG-COOH with a volume ratio of 2.2, which allowed the recovery of 96% of IgG in the PEG-rich phase with a final IgG concentration of 0.21mg/mL, a protein purity of 87% and a total purity of 43%. In order to enhance simultaneously both recovery yield and purity, a four stage cross-current operation was simulated and the corresponding liquid-liquid equilibrium (LLE) data determined. A predicted optimised scheme of a counter-current multi-stage aqueous two-phase extraction was hence described. IgG can be purified in the PEG-rich top phase with a final recovery yield of 95%, a final concentration of 1.04mg/mL and a protein purity of 93%, if a PEG/dextran ATPS containing 1.3% (w/w) TEG-COOH, 5 stages and volume ratio of 0.4 are used. Moreover, according to the LLE data of all CHO cells supernatant components, it was possible to observe that most of the cells supernatant contaminants can be removed during this extraction step leading to a final total purity of about 85%.
Martens, Chelsea J.; Inglis, Sarah K.; Valentine, Vincent G.; Garrison, Jennifer; Conner, Gregory E.
2011-01-01
To better understand how airways produce thick airway mucus, nonvolatile solids were measured in liquid secreted by bronchi from normal pig, cystic fibrosis (CF) human, and non-CF human lungs. Bronchi were exposed to various secretagogues and anion secretion inhibitors to induce a range of liquid volume secretion rates. In all three groups, the relationship of solids concentration (percent nonvolatile solids) to liquid volume secretion rate was curvilinear, with higher solids concentration associated with lower rates of liquid volume secretion. In contrast, the secretion rates of solids mass and water mass as functions of liquid volume secretion rates exhibited positive linear correlations. The y-intercepts of the solids mass-liquid volume secretion relationships for all three groups were positive, thus accounting for the higher solids concentrations in airway liquid at low rates of secretion. Predictive models derived from the solids mass and water mass linear equations fit the experimental percent solids data for the three groups. The ratio of solids mass secretion to liquid volume secretion was 5.2 and 2.4 times higher for CF bronchi than for pig and non-CF bronchi, respectively. These results indicate that normal pig, non-CF human, and CF human bronchi produce a high-percent-solids mucus (>8%) at low rates of liquid volume secretion (≤1.0 μl·cm−2·h−1). However, CF bronchi produce mucus with twice the percent solids (∼8%) of pig or non-CF human bronchi at liquid volume secretion rates ≥4.0 μl·cm−2·h−1. PMID:21622844
Code of Federal Regulations, 2011 CFR
2011-07-01
..., including all gas flared, gas vented, and liquid hydrocarbons burned, to Minerals Revenue Management on Form... and maintain records detailing gas flaring, gas venting, and liquid hydrocarbon burning for each... include, at a minimum: (i) Daily volumes of gas flared, gas vented, and liquid hydrocarbons burned; (ii...
Global constraints on Z2 fluxes in two different anisotropic limits of a hypernonagon Kitaev model
NASA Astrophysics Data System (ADS)
Kato, Yasuyuki; Kamiya, Yoshitomo; Nasu, Joji; Motome, Yukitoshi
2018-05-01
The Kitaev model is an exactly-soluble quantum spin model, whose ground state provides a canonical example of a quantum spin liquid. Spin excitations from the ground state are fractionalized into emergent matter fermions and Z2 fluxes. The Z2 flux excitation is pointlike in two dimensions, while it comprises a closed loop in three dimensions because of the local constraint for each closed volume. In addition, the fluxes obey global constraints involving (semi)macroscopic number of fluxes. We here investigate such global constraints in the Kitaev model on a three-dimensional lattice composed of nine-site elementary loops, dubbed the hypernonagon lattice, whose ground state is a chiral spin liquid. We consider two different anisotropic limits of the hypernonagon Kitaev model where the low-energy effective models are described solely by the Z2 fluxes. We show that there are two kinds of global constraints in the model defined on a three-dimensional torus, namely, surface and volume constraints: the surface constraint is imposed on the even-odd parity of the total number of fluxes threading a two-dimensional slice of the system, while the volume constraint is for the even-odd parity of the number of the fluxes through specific plaquettes whose total number is proportional to the system volume. In the two anisotropic limits, therefore, the elementary excitation of Z2 fluxes occurs in a pair of closed loops so as to satisfy both two global constraints as well as the local constraints.
Compact dry chemistry instruments.
Terashima, K; Tatsumi, N
1999-01-01
Compact dry chemistry instruments are designed for use in point-of-care-testing (POCT). These instruments have a number of advantages, including light weight, compactness, ease of operation, and the ability to provide accurate results in a short time with a very small sample volume. On the other hand, reagent costs are high compared to liquid method. Moreover, differences in accuracy have been found between dry chemistry and the liquid method in external quality assessment scheme. This report examines reagent costs and shows how the total running costs associated with dry chemistry are actually lower than those associated with the liquid method. This report also describes methods for minimizing differences in accuracy between dry chemistry and the liquid method. Use of these measures is expected to increase the effectiveness of compact dry chemistry instruments in POCT applications.
Azevedo, R A; Machado, F S; Campos, M M; Lopes, D R G; Costa, S F; Mantovani, H C; Lopes, F C F; Marcondes, M I; Pereira, L G R; Tomich, T R; Coelho, S G
2016-11-01
The aim of this study was to evaluate the effects on feed intake, calf performance, feed efficiency, fecal score, passage rate, apparent nutrient digestibility, development of rumen and other organs, and body composition of increasing the total solids content of liquid feed (whole milk) by adding increasing amounts of milk replacer powder during the preweaning period. Crossbred Holstein-Gyr calves (n=32) were assigned to 1 of 4 treatments (n=8 per group), which consisted of different total solids concentrations: 12.5, 15.0, 17.5, and 20.0% of liquid feed. Calves received 6 L of liquid per day, divided into 2 equal meals (0800 and 1600 h) and provided in buckets, from 5 to 55d of age. Starter and water were provided ad libitum during the entire experiment. At 56d of age, animals were killed. Laboratory analysis determined that the actual total solids contents of the liquid feed were 13.5, 16.1, 18.2, and 20.4%, for the proposed 12.5, 15.0, 17.5, and 20.0% total solids treatments, respectively. The osmolality of liquid feed treatments was 265 to 533 mOsm/L. Fecal score was similar among treatments, except for wk 2 and 7. Intake of liquid feed was similar among treatments from 6wk of age. During wk 4, 5, and 6, we detected a linear decrease in starter intake. After wk 7, we observed greater starter intake for calves fed approximately 16.1% total solids. Water intake, feed efficiency, and withers height were similar among treatments. Increasing concentrations of total solids in liquid feed quadratically affected average daily gain, final body weight, and empty body weight. We observed a greater average daily gain for calves fed approximately 20.4% total solids. Passage rate, nutrient digestibility, development of pre-stomachs and intestine, and body composition were similar among treatments. Increasing the concentration of total solids in liquid feed up to 20.4% reduced starter intake between 4 and 6wk of life, but increased average daily gain. It did not affect passage rate, nutrient digestibility, ruminal and organ development, or body composition in calves during the preweaning period, indicating that this strategy may be a viable alternative for feeding without increasing the total volume of liquid feed provided to dairy calves. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Controlling the pressure within an annular volume of a wellbore
Hermes, Robert E.; Gonzalez, Manuel E.; Llewellyn, Brian C.; Bloys, James B.
2008-10-28
A process is described for replacing at least a portion of the liquid within the annular volume of a casing system within a wellbore with a second liquid. The second liquid is preselected to provide a measure of control of the pressure within the annular volume as the fluid within the volume is being heated.
Controlling the pressure within an annular volume of a wellbore
Hermes, Robert E [Los Alamos, NM; Gonzalez, Manuel E [Kingwood, TX; Llewellyn, Brian C [Kingwood, TX; Bloys, James B [Katy, TX; Coates, Don M [Santa Fe, NM
2011-05-31
A process is described for replacing at least a portion of the liquid within the annular volume of a casing system within a wellbore with a second liquid. The second liquid is preselected to provide a measure of control of the pressure within the annular volume as the fluid within the volume is being heated.
Controlling the pressure within an annular volume of a wellbore
Hermes, Robert E [Los Alamos, NM; Gonzalez, Manuel E [Kingwood, TX; Llewellyn, Brian C [Kingwood, TX; Bloys, James B [Katy, TX
2011-01-18
A process is described for replacing at least a portion of the liquid within the annular volume of a casing system within a wellbore with a second liquid. The second liquid is preselected to provide a measure of control of the pressure within the annular volume as the fluid within the volume is being heated.
Controlling the pressure within an annular volume of a wellbore
Hermes, Robert E.; Gonzalez, Manuel E.; Llewellyn, Brian C.; Bloys, James B.
2010-06-29
A process is described for replacing at least a portion of the liquid within the annular volume of a casing system within a wellbore with a second liquid. The second liquid is preselected to provide a measure of control of the pressure within the annular volume as the fluid within the volume is being heated.
Controlling the pressure within an annular volume of a wellbore
Hermes, Robert E [Los Alamos, NM; Gonzalez, Manuel E [Kingwood, NM; Llewellyn, Brian C [Kingwood, TX; Bloys, James B [Katy, TX; Coates, Don M [Santa Fe, NM
2011-06-21
A process is described for replacing at least a portion of the liquid within the annular volume of a casing system within a wellbore with a second liquid. The second liquid is preselected to provide a measure of control of the pressure within the annular volume as the fluid within the volume is being heated.
3-D Distribution of Retained Colloids in Unsaturated Porous Media
NASA Astrophysics Data System (ADS)
Morales, V. L.; Perez-Reche, F. J.; Holzner, M.; Kinzelbach, W. K.; Otten, W.
2013-12-01
It is well accepted that colloid transport processes in porous media differ substantially between water saturated and unsaturated conditions. Differences are frequently ascribed to colloid immobilization by association with interfaces with the gas, as well as to restrictions of the liquid medium through which colloids are transported. Such factors depend on interfacial conditions provided by the water saturation of the porous medium. Yet, the current understanding of the importance of colloid retention at gas interfaces is based on observations of single pores or two-dimensional pore network representations, leaving open the question of their statistical significance when all pores in the medium are considered. In order to address this question, column experiments were performed using a model porous medium of glass beads through which colloidal silver particles were transported for conditions of varying water content. X-ray microtomography was subsequently employed as a non-destructive imaging technique to obtain pore-scale information of the entire column regarding: i) the presence and distribution of the four main locations where colloids can become retained (interfaces with the liquid-solid, gas-liquid and gas-solid, and the bulk liquid), ii) deposition profiles of colloids along the column classified by the available retention location, iii) morphological characteristics of the deposited colloidal aggregates, and iv) channel widths of 3-dimensional pore-water network representations. The results presented provide, for the first time, a direct statistical evaluation on the significance of colloid retention by attachment to the liquid-solid, gas-liquid, gas-solid interfaces, and by straining in the bulk liquid. Additionally, an effective-pore structure characteristic is proposed to improve predictions of mass removal by straining under various water saturations. A) Unsaturated conditions. B) Saturated conditions. Left: Tomograph slice illustrating with false coloring Regions Of Interest corresponding to retention locations at the gas-liquid (purple), gas-solid (white) and solid-liquid interface (blue), and the bulk liquid (teal). Right: Deposition profiles of silver colloids (Ag) per retention location (T: total, GLI: gas-liquid interface, GSI: gas-solid interface, SLI: solid-liquid interface, L: bulk liquid) (Top). Depth profiles of the volume occupied by each retention location (Middle). Normalized deposition profiles of silver volume retained by its corresponding retention-location volume (Bottom).
Code of Federal Regulations, 2012 CFR
2012-07-01
..., gas vented, and liquid hydrocarbons burned, to Office of Natural Resources Revenue on Form ONRR-4054... records detailing gas flaring, gas venting, and liquid hydrocarbon burning for each facility for 6 years... minimum: (i) Daily volumes of gas flared, gas vented, and liquid hydrocarbons burned; (ii) Number of hours...
Code of Federal Regulations, 2010 CFR
2010-07-01
..., and Burning Hydrocarbons § 250.1163 How must I measure gas flaring or venting volumes and liquid... vented, and liquid hydrocarbons burned, to Minerals Revenue Management on Form MMS-4054 (Oil and Gas... gas flaring, gas venting, and liquid hydrocarbon burning for each facility for 6 years. (1) You must...
Code of Federal Regulations, 2013 CFR
2013-07-01
..., gas vented, and liquid hydrocarbons burned, to Office of Natural Resources Revenue on Form ONRR-4054... records detailing gas flaring, gas venting, and liquid hydrocarbon burning for each facility for 6 years... minimum: (i) Daily volumes of gas flared, gas vented, and liquid hydrocarbons burned; (ii) Number of hours...
Code of Federal Regulations, 2014 CFR
2014-07-01
..., gas vented, and liquid hydrocarbons burned, to Office of Natural Resources Revenue on Form ONRR-4054... records detailing gas flaring, gas venting, and liquid hydrocarbon burning for each facility for 6 years... minimum: (i) Daily volumes of gas flared, gas vented, and liquid hydrocarbons burned; (ii) Number of hours...
Robust sensor for turbidity measurement from light scattering and absorbing liquids.
Kontturi, Ville; Turunen, Petri; Uozumi, Jun; Peiponen, Kai-Erik
2009-12-01
Internationally standardized turbidity measurements for probing solid particles in liquid are problematic in the case of simultaneous light scattering and absorption. A method and a sensor to determine the turbidity in the presence of light absorption are presented. The developed sensor makes use of the total internal reflection of a laser beam at the liquid-prism interface, and the turbidity is assessed using the concept of laser speckle pattern. Using average filtering in speckle data analyzing the observed dynamic speckle pattern, which is due to light scattering from particles and the static speckle due to stray light of the sensor, can be separated from each other. Good correlation between the standard deviation of dynamic speckle and turbidity value for nonabsorbing and for absorbing liquids was observed. The sensor is suggested, for instance, for the measurement of ill-behaved as well as small-volume turbid liquids in both medicine and process industry.
Analysis of Drop Shapes during Electrowetting on a Dielectric
NASA Astrophysics Data System (ADS)
Daneshbod, Yousef
2005-03-01
Electrowetting refers to the electrostatic control of the interfacial energy of a liquid on a solid, primarily used for the transport of micro-liter volumes of drops on surfaces with embedded electrode arrays. In the present work, the drop is modeled as a two-dimensional lens-like conductor immersed in an infinite dielectric medium slightly above a planar conductor. A matched asymptotic expansion is used to approximate the electrostatic field surrounding the drop. The outer problem models the drop as a conducting circular segment resting on the conducting plane, each maintained at a separate constant potential. The inner problem corrects the region near the edge of the drop by modeling it as an infinite planar conducting wedge lying slightly above the conducting plane. By matching the inner and outer solutions, the charge density along the entire surface of the drop can be approximated, enabling the calculation of the total capacitance of the system. An energy minimization method similar to that of Shapiro et al. [J. Appl. Phys., 93, 5794 (2003)] is applied to the total energy consisting of the liquid/gas, liquid/solid and solid/gas surface energies, together with the electrostatic contribution, subject to the constraint that the drop volume remains constant. A modified form of the Young-Lippmann equation is thus derived that includes the contribution from the extra capacitance of the drop obtained via matched asymptotics.
Polarized Raman spectroscopic study of relaxed high density amorphous ices under pressure.
Suzuki, Yoshiharu; Tominaga, Yasunori
2010-10-28
We have made high density amorphous ice (HDA) by the pressure-induced amorphization of hexagonal ice at 77 K and measured the volume change on isobaric heating in a pressure range between 0.1 and 1.5 GPa. The volume of HDA on heating below ∼0.35 GPa increases, while the volume of HDA on heating above ∼0.35 GPa decreases. The polarized OH-stretching Raman spectra of the relaxed HDAs are compared with that of the unannealed HDA. The relaxed HDAs are prepared at 0.2 GPa at 130 K and 1.5 GPa at 160 K. It is found that the relatively strong totally symmetric OH-stretching vibration mode around 3100 cm(-1) exists in the depolarized reduced Raman spectrum χ(VH)(") of the unannealed HDA and that its intensity rapidly decreases by relaxation. The χ(VH)(") profiles of the relaxed HDA are similar to those of liquid water. These results indicate that the HDA reaches a nearly equilibrium state by annealing and the intrinsic state of HDA relates to a liquid state. The pressure-volume curve of the relaxed HDA at 140 K seems to be smooth in the pressure range below 1.5 GPa.
Ultrathin zoom telescopic objective.
Li, Lei; Wang, Di; Liu, Chao; Wang, Qiong-Hua
2016-08-08
We report an ultrathin zoom telescopic objective that can achieve continuous zoom change and has reduced compact volume. The objective consists of an annular folded lens and three electrowetting liquid lenses. The annular folded lens undertakes the main part of the focal power of the lens system. Due to a multiple-fold design, the optical path is folded in a lens with the thickness of ~1.98mm. The electrowetting liquid lenses constitute a zoom part. Based on the proposed objective, an ultrathin zoom telescopic camera is demonstrated. We analyze the properties of the proposed objective. The aperture of the proposed objective is ~15mm. The total length of the system is ~18mm with a tunable focal length ~48mm to ~65mm. Compared with the conventional zoom telescopic objective, the total length has been largely reduced.
How pinning and contact angle hysteresis govern quasi-static liquid drop transfer.
Chen, H; Tang, T; Zhao, H; Law, K-Y; Amirfazli, A
2016-02-21
This paper presents both experimental and numerical simulations of liquid transfer between two solid surfaces with contact angle hysteresis (CAH). Systematic studies on the role of the advancing contact angle (θa), receding contact angle (θr) and CAH in determining the transfer ratio (volume of the liquid transferred onto the acceptor surface over the total liquid volume) and the maximum adhesion force (Fmax) were performed. The transfer ratio was found to be governed by contact line pinning at the end of the transfer process caused by CAH of surfaces. A map based on θr of the two surfaces was generated to identify the three regimes for liquid transfer: (I) contact line pinning occurs only on the donor surface, (II) contact line pinning occurs on both surfaces, and (III) contact line pinning occurs only on the acceptor surface. With this map, an empirical equation is provided which is able to estimate the transfer ratio by only knowing θr of the two surfaces. The value of Fmax is found to be strongly influenced by the contact line pinning in the early stretching stage. For symmetric liquid bridges between two identical surfaces, Fmax may be determined only by θa, only by θr, or by both θa and θr, depending on the magnitude of the contact angles. For asymmetric bridges, Fmax is found to be affected by the period when contact lines are pinned on both surfaces.
NASA Astrophysics Data System (ADS)
Tirandazi, Pooyan; Hidrovo, Carlos
2015-11-01
Over the last few years, microfluidic systems known as Lab-on-a-Chip (LOC) and micro total analysis systems (μTAS) have been increasingly developed as essential components for numerous biochemical applications. Droplet microfluidics, however, provides a distinctive attribute for delivering and processing discrete as well as ultrasmall volumes of fluid, which make droplet-based systems more beneficial over their continuous-phase counterparts. Droplet generation in its conventional scheme usually incorporates the injection of a liquid (water) into a continuous immiscible liquid (oil) medium. In this study we demonstrate a novel scheme for controlled generation of monodisperse droplets in confined gas-liquid microflows. We experimentally investigate the manipulation of water droplets in flow-focusing configurations using a high inertial air stream. Different flow regimes are observed by varying the gas and liquid flow rates, among which, the ``dripping regime'' where monodisperse droplets are generated is of great importance. The controlled size and generation rate of droplets in this region provide the capability for precise and contaminant-free delivery of microliter to nanoliter volumes of fluid. Furthermore, the high speed droplets generated in this method represent the basis for a new approach based on droplet pair collisions for fast efficient micromixing which provides a significant development in modern LOC and μTAS devices. This project is currently being supported by an NSF CAREER Award grant CBET-1151091.
VOLUME COMPENSATING MEANS FOR PULSATING PUMPS
Weaver, D.L.W.; MacCormack, R.S. Jr.
1959-12-01
A double diaphragm, two-liquid pulsating pump for remote control use, having as an improvement an apparatus for maintaining constant the volume of the liquid such as kerosene between the two diaphragms is described. Phase difficulties encountered in the operation of such pumps when the volume of the liquid is altered by changes in temperature are avoided.
Griffin, Dale W.; Gonzalez, C.; Teigell, N.; Petrosky, T.; Northup, D.E.; Lyles, M.
2011-01-01
The influence of sample-collection-time on the recovery of culturable airborne microorganisms using a low-flow-rate membrane-filtration unit and a high-flow-rate liquid impinger were investigated. Differences in recoveries were investigated in four different atmospheric environments, one mid-oceanic at an altitude of ~10.0 m, one on a mountain top at an altitude of ~3,000.0 m, one at ~1.0 m altitude in Tallahassee, Florida, and one at ~1.0 m above ground in a subterranean-cave. Regarding use of membrane filtration, a common trend was observed: the shorter the collection period, the higher the recovery of culturable bacteria and fungi. These data also demonstrated that lower culturable counts were common in the more remote mid-oceanic and mountain-top atmospheric environments with bacteria, fungi, and total numbers averaging (by sample time or method categories) <3.0 colony-forming units (CFU) m -3. At the Florida and subterranean sites, the lowest average count noted was 3.5 bacteria CFU m-3, and the highest averaged 140.4 total CFU m-3. When atmospheric temperature allowed use, the high-volume liquid impinger utilized in this study resulted in much higher recoveries, as much as 10?? greater in a number of the categories (bacterial, fungal, and total CFU). Together, these data illustrated that (1) the high-volume liquid impinger is clearly superior to membrane filtration for aeromicrobiology studies if start-up costs are not an issue and temperature permits use; (2) although membrane filtration is more cost friendly and has a 'typically' wider operational range, its limits include loss of cell viability with increased sample time and issues with effectively extracting nucleic acids for community-based analyses; (3) the ability to recover culturable microorganisms is limited in 'extreme' atmospheric environments and thus the use of a 'limited' methodology in these environments must be taken into account; and (4) the atmosphere culls, i.e., everything is not everywhere. ?? 2010 US Government.
NASA Astrophysics Data System (ADS)
Fisenko, Anatoliy I.; Lemberg, Vladimir F.
2016-09-01
The knowledge of thermal radiative and thermodynamic properties of uranium and plutonium carbides under extreme conditions is essential for designing a new metallic fuel materials for next generation of a nuclear reactor. The present work is devoted to the study of the thermal radiative and thermodynamic properties of liquid and solid uranium and plutonium carbides at their melting/freezing temperatures. The Stefan-Boltzmann law, total energy density, number density of photons, Helmholtz free energy density, internal energy density, enthalpy density, entropy density, heat capacity at constant volume, pressure, and normal total emissivity are calculated using experimental data for the frequency dependence of the normal spectral emissivity of liquid and solid uranium and plutonium carbides in the visible-near infrared range. It is shown that the thermal radiative and thermodynamic functions of uranium carbide have a slight difference during liquid-to-solid transition. Unlike UC, such a difference between these functions have not been established for plutonium carbide. The calculated values for the normal total emissivity of uranium and plutonium carbides at their melting temperatures is in good agreement with experimental data. The obtained results allow to calculate the thermal radiative and thermodynamic properties of liquid and solid uranium and plutonium carbides for any size of samples. Based on the model of Hagen-Rubens and the Wiedemann-Franz law, a new method to determine the thermal conductivity of metals and carbides at the melting points is proposed.
US crude oil, natural gas, and natural gas liquids reserves 1996 annual report
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1997-12-01
The EIA annual reserves report series is the only source of comprehensive domestic proved reserves estimates. This publication is used by the Congress, Federal and State agencies, industry, and other interested parties to obtain accurate estimates of the Nation`s proved reserves of crude oil, natural gas, and natural gas liquids. These data are essential to the development, implementation, and evaluation of energy policy and legislation. This report presents estimates of proved reserves of crude oil, natural gas, and natural gas liquids as of December 31, 1996, as well as production volumes for the US and selected States and State subdivisionsmore » for the year 1996. Estimates are presented for the following four categories of natural gas: total gas (wet after lease separation), nonassociated gas and associated-dissolved gas (which are the two major types of wet natural gas), and total dry gas (wet gas adjusted for the removal of liquids at natural gas processing plants). In addition, reserve estimates for two types of natural gas liquids, lease condensate and natural gas plant liquids, are presented. Also included is information on indicated additional crude oil reserves and crude oil, natural gas, and lease condensate reserves in nonproducing reservoirs. A discussion of notable oil and gas exploration and development activities during 1996 is provided. 21 figs., 16 tabs.« less
Effects of viscosity, taste, and bolus volume on swallowing apnea duration of normal adults.
Butler, Susan G; Postma, Gregory N; Fischer, Eileen
2004-12-01
The effects of viscosity, taste, and nectar-thick liquid bolus volume on swallowing apnea duration (SAD) were examined. Twenty-two adults, comprised of 10 males and 12 females, participated. SAD was assessed via nasal airflow during swallow conditions of viscosity (thin liquid, thick liquid, and puree), taste (water, apple juice, lemon concentrate), and nectar-thick liquid bolus volumes (5, 10, 15, and 20 mL) across three trials. A significant main effect of nectar-thick liquid bolus volume was found (P < 0.05). Viscosity and taste were not significant. SAD increased with increases in bolus volume; however, neither changes in bolus viscosity nor changes in taste affected SAD. These findings indicate that since viscosity was not significant, the normative data previously published (by this PI) with 60 healthy adults stratified by age and gender can be utilized for comparison to disordered swallowing without regard to the bolus viscosity being used. D.
Addis, Temesgen; Teshome, Asmamaw; Strauch, Olaf; Ehlers, Ralf-Udo
2016-05-01
Entomopathogenic nematodes (Steinernema spp.) are used in integrated pest management to control insect pests in cryptic environments. The nematodes are mass produced in monoxenic liquid culture with their symbiotic bacteria Xenorhabdus spp. For a better understanding of nematode population dynamics, the life history traits (LHTs) of the entomopathogenic nematode Steinernema feltiae were assessed at 25 °C by observing single pairs of male and female nematodes using a hanging drop technique. To investigate the influence of different food supplies on nematode reproduction, the LHTs were assessed with a daily supply of 5 ×, 10 × and 20 × 10(9) cells ml(-1) of the nematode's bacterial symbiont Xenorhabdus bovienii in semi-solid nematode growth gelrite (NGG) medium. Increasing bacterial density had a significant positive influence on the average number of offspring produced, which ranged from 359 to 813 per female. The intrinsic rate of natural increase r m, which ranges from 1.10 to 1.19 day(-1), was neither influenced by the bacterial density, nor was the mean generation time T (5.12-5.25 days) and population doubling time (PDT) (0.64-0.59 days). The average lifespan of reproductive females, which ranged from 6.7 to 7.3 days, was positively correlated with bacterial density. A positive correlation between female body volume and bacterial density was recorded (R = 0.67) as well as a significant positive correlation between female body size and offspring production (R = 0.89) in hanging drops. Whether these data can be used to predict nematode yields in liquid culture was tested. The total female body volume calculated as the average female body volume × total number of parental females per millilitre 3 days after nematode inoculation was positively correlated (R = 0.72) with nematode yields. The total female body volume on process day 3 is thus a good indicator for the estimation of nematode yield at the end of the process (12-15 days post dauer juvenile (DJ) inoculation) in both Erlenmeyer flasks and bioreactors. With a mean deviation of 9467 DJs ml(-1), the error resembles approximately 5 % of the final DJ yields.
Multi-phase-fluid discrimination with local fibre-optical probes: III. Three-phase flows
NASA Astrophysics Data System (ADS)
Fordham, E. J.; Ramos, R. T.; Holmes, A.; Simonian, S.; Huang, S.-M.; Lenn, C. P.
1999-12-01
Local fibre-optical sensors (or `local probes') for immiscible-fluid discrimination are demonstrated in three-phase (oil/water/gas) flows. The probes are made from standard silica fibres with plane oblique facets polished at the fibre tip, with surface treatment for wettability control. They use total internal reflection to distinguish among drops, bubbles and other regions of fluid in multi-phase flows, on the basis of refractive-index contrast. Dual probes, using two sensors each with a quasi-binary output, are used to determine profiles of three-phase volume fraction in a flow of kerosene, water and air in a pipe. The individual sensors used discriminate oil from `not-oil' and gas from liquid; their logical combination discriminates among the three phases. Companion papers deal with the sensor designs used and quantitative results achieved in the simpler two-phase cases of liquid/liquid flows and gas/liquid flows.
Radiofrequency ablation during continuous saline infusion can extend ablation margins
Ishikawa, Toru; Kubota, Tomoyuki; Horigome, Ryoko; Kimura, Naruhiro; Honda, Hiroki; Iwanaga, Akito; Seki, Keiichi; Honma, Terasu; Yoshida, Toshiaki
2013-01-01
AIM: To determine whether fluid injection during radiofrequency ablation (RFA) can increase the coagulation area. METHODS: Bovine liver (1-2 kg) was placed on an aluminum tray with a return electrode affixed to the base, and the liver was punctured by an expandable electrode. During RFA, 5% glucose; 50% glucose; or saline fluid was infused continuously at a rate of 1.0 mL/min through the infusion line connected to the infusion port. The area and volume of the thermocoagulated region of bovine liver were determined after RFA. The Joule heat generated was determined from the temporal change in output during the RFA experiment. RESULTS: No liquid infusion was 17.3 ± 1.6 mL, similar to the volume of a 3-cm diameter sphere (14.1 mL). Mean thermocoagulated volume was significantly larger with continuous infusion of saline (29.3 ± 3.3 mL) than with 5% glucose (21.4 ± 2.2 mL), 50% glucose (16.5 ± 0.9 mL) or no liquid infusion (17.3 ± 1.6 mL). The ablated volume for RFA with saline was approximately 1.7-times greater than for RFA with no liquid infusion, representing a significant difference between these two conditions. Total Joule heat generated during RFA was highest with saline, and lowest with 50% glucose. CONCLUSION: RFA with continuous saline infusion achieves a large ablation zone, and may help inhibit local recurrence by obtaining sufficient ablation margins. RFA during continuous saline infusion can extend ablation margins, and may be prevent local recurrence. PMID:23483097
40 CFR 799.2155 - Commercial hexane.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) “Commercial hexane,” for purposes of this section, is a product obtained from crude oil, natural gas liquids... least 40 liquid volume percent n-hexane (CAS No. 110-54-3) and at least 5 liquid volume percent... section, is a product which conforms to the specifications of ASTM D1836 and contains at least 40 liquid...
Theories of hydrophobic effects and the description of free volume in complex liquids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pratt, L.R.; Garde, S.; Hummer, G.
1998-12-31
Recent progress on molecular theories of hydration of nonpolar solutes in liquid aqueous solution has lead to new ways to thinking about the old issue of free volume in liquids. This article surveys the principal new results with particular attention to the context of general issues of packing in liquids.
Measurement of gastric meal and secretion volumes using magnetic resonance imaging
Hoad, C.L.; Parker, H.; Hudders, N.; Costigan, C.; Cox, E.F.; Perkins, A.C.; Blackshaw, P.E.; Marciani, L.; Spiller, R.C.; Fox, M.R.; Gowland, P.A.
2015-01-01
MRI can assess multiple gastric functions without ionizing radiation. However, time consuming image acquisition and analysis of gastric volume data, plus confounding of gastric emptying measurements by gastric secretions mixed with the test meal have limited its use to research centres. This study presents an MRI acquisition protocol and analysis algorithm suitable for the clinical measurement of gastric volume and secretion volume. Reproducibility of gastric volume measurements was assessed using data from 10 healthy volunteers following a liquid test meal with rapid MRI acquisition within one breath-hold and semi-automated analysis. Dilution of the ingested meal with gastric secretion was estimated using a respiratory-triggered T1 mapping protocol. Accuracy of the secretion volume measurements was assessed using data from 24 healthy volunteers following a mixed (liquid/solid) test meal with MRI meal volumes compared to data acquired using gamma scintigraphy (GS) on the same subjects studied on a separate study day. The mean (SD) coefficient of variance between 3 observers for both total gastric contents (including meal, secretions and air) and just the gastric contents (meal and secretion only) was 3 (2) % at large gastric volumes (> 200 ml). Mean (SD) secretion volumes post meal ingestion were 64 (51) ml and 110 (40) ml at 15 and 75 minutes respectively. Comparison with GS meal volumes, showed that MRI meal only volume (after correction for secretion volume) were similar to GS, with a linear regression gradient (std err) of 1.06 (0.10) and intercept −11 (24) ml. In conclusion, (i) rapid acquisition removed the requirement to image during prolonged breath-hold (ii) semi-automatic analysis greatly reduced time required to derive measurements and (iii) correction for secretion volumes provides accurate assessment of gastric meal volumes and emptying. Together these features provide the scientific basis of a protocol which would be suitable in clinical practice. PMID:25592405
NASA Technical Reports Server (NTRS)
Doane, George B., III; Armstrong, W. C.
1990-01-01
Research on propulsion stability (chugging and acoustic modes), and propellant valve control was investigated. As part of the activation of the new liquid propulsion test facilities, it is necessary to analyze total propulsion system stability. To accomplish this, several codes were built to run on desktop 386 machines. These codes enable one to analyze the stability question associated with the propellant feed systems. In addition, further work was adapted to this computing environment and furnished along with other codes. This latter inclusion furnishes those interested in high frequency oscillatory combustion behavior (that does not couple to the feed system) a set of codes for study of proposed liquid rocket engines.
Tank gauging apparatus and method
NASA Technical Reports Server (NTRS)
Morris, Brian G. (Inventor)
1990-01-01
An apparatus for gauging the amount of liquid in a container of liquid and gas under low or zero gravity net conditions includes an accumulator and appropriate connector apparatus for communicating gas between the accumulator and the container. In one form of the invention, gas is removed from the container and compressed into the accumulator. The pressure and temperature of the fluid in the container is measured before and after removal of the gas; the pressure and temperature of the gas in the accumulator is measured before and after compression of the gas into the accumulator from the container. These pressure and temperature measurements are used to determine the volume of gas in the container, whereby the volume of the liquid in the container can be determined from the difference between the known volume of the container and the volume of gas in the container. Gas from the accumulator may be communicated into the container in a similar process as a verification of the gauging of the liquid volume, or as an independent process for determining the volume of liquid in the container.
Tank gauging apparatus and method
NASA Technical Reports Server (NTRS)
Morris, Brian G. (Inventor)
1991-01-01
Apparatus for gauging the amount of liquid in a container of liquid and gas under flow or zero gravity net conditions includes an accumulator and appropriate connector apparatus for communicating gas between the accumulator and the container. In one form of the invention, gas is removed from the container and compressed into the accumulator. The pressure and temperature of the fluid in the container is measured before and after removal of the gas; the pressure and temperature of gas in the accumulator is measured before and after compression of the gas into the accumulator from the container. These pressure and temperature measurements are used in determining the volume of gas in the container, whereby the volume of liquid in the container can be determined from the difference between the known volume of the container and the volume of gas in the container. Gas from the accumulator may be communicated into the container in a similar process as a verification of the gauging of the liquid volume, or as an independent process for determining the volume of liquid in the container.
Treatability Variance for Containerised Liquids in Mixed Debris Waste - 12101
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alstatt, Catherine M.
2012-07-01
The TRU Waste Processing Center (TWPC) is a Department of Energy facility whose mission is to receive and process for appropriate disposal legacy Contact Handled (CH) and Remote Handled (RH) waste, including debris waste stored at various DOE Oak Ridge facilities. Acceptable Knowledge (AK) prepared for the waste characterizes the waste as mixed waste, meaning it is both radioactive and regulated under the Resource Conservation and Recovery Act (RCRA). The AK also indicates that a number of the debris waste packages contain small amounts of containerised liquids. The documentation indicates liquid wastes generated in routine lab operations were typically collectedmore » for potential recovery of valuable isotopes. However, during activities associated with decontamination and decommissioning (D and D), some containers with small amounts of liquids were placed into the waste containers with debris waste. Many of these containers now hold from 2.5 milliliters (ml) to 237 ml of liquid; a few contain larger volumes. At least some of these containers were likely empty at the time of generation, but documentation of this condition is lacking. Since WIPP compliant AK is developed on a waste stream basis, rather than an individual container basis, and includes every potential RCRA hazardous constituent within the waste stream, it is insufficient for the purpose of characterizing individual containers of liquid. Debris waste is defined in 40 CFR 268.2(g) as 'solid material exceeding a 60 mm particle size that is intended for disposal and that is: a manufactured object; or plant or animal matter; or natural geologic material'. The definition further states that intact containers of hazardous waste that are not ruptured and that retain at least 75% of their original volume are not debris. The prescribed treatment is removal of intact containers from the debris waste, and treatment of their contents to meet specific Land Disposal Restrictions (LDR) standards. This is true for containers with incidental amounts of liquids, even if the liquid is less than 50% of the total waste volume. Under the proposed variance, all free or containerised liquids (up to 3.8 liters(L)) found in the debris would be treated and returned in solid form to the debris waste stream from which they originated. The waste would then be macro-encapsulated. (author)« less
Cunha, S C; Fernandes, J O
2010-11-15
A novel method combining dispersive liquid-liquid microextraction (DLLME) and heart-cutting multidimensional gas chromatography coupled to mass spectrometry was developed for the determination of free and total bisphenol A (BPA) and bisphenol B (BPB) in human urine samples. The DLLME procedure combines extraction, derivatization and concentration of the analytes into one step. Several important variables influencing the extraction efficiency and selectivity such as nature and volume of extractive and dispersive solvents as well as the amount of acetylating reagent were investigated. The temperature and time to hydrolyze BPA and BPB conjugates with a β-glucuronidase and sulfatase enzyme preparation were also studied. Under the optimized conditions good efficiency extraction (71-93%) and acceptable total DLLME yields (56-77%) were obtained for both analytes. Matrix-matched calibration curves were linear with correlation coefficients higher than 0.996 in the range level 0.1-5 μg/l, and the relative standard deviations (%RSD) were lower than 20% (n=6). The limits of detection were 0.03 and 0.05 μg/l for BPA and BPB, respectively. The applicability of the proposed method for determining urinary free and total BPA and BPB was assessed by analyzing the human urine of a group of 20 volunteers. Free BPA was detected in 45% of the sample whereas total BPA was detected in 85% of the samples at concentrations ranging between 0.39 and 4.99 μg/l. BPB was detected in conjugated form in two samples. Copyright © 2010 Elsevier B.V. All rights reserved.
Pressure, O2, and CO2, in aquatic Closed Ecological Systems
NASA Astrophysics Data System (ADS)
Taub, Frieda B.; McLaskey, Anna K.
2013-03-01
Pressure increased during net photosynthetic O2 production in the light and decreased during respiratory O2 uptake during the dark in aquatic Closed Ecological Systems (CESs) with small head gas volumes. Because most CO2 will be in the liquid phase as bicarbonate and carbonate anions, and CO2 is more soluble than O2, volumes of gaseous CO2 and gaseous O2 will not change in a compensatory manner, leading to the development of pressure. Pressure increases were greatest with nutrient rich medium with NaHCO3 as the carbon source. With more dilute media, pressure was greatest with NaHCO3, and less with cellulose or no-added carbon. Without adequate turbulence, pressure measurements lagged dissolved O2 concentrations by several hours and dark respiration would have been especially underestimated in our systems (250-1000 ml). With adequate turbulence (rotary shaker), pressure measurements and dissolved O2 concentrations generally agreed during lights on/off cycles, but O2 measurements provided more detail. At 20 °C, 29.9 times as much O2 will distribute into the gas phase as in the liquid, per unit volume, as a result of the limited solubility of O2 in water and according to Henry's Law. Thus even a small head gas volume can contain more O2 than a larger volume of water. When both dissolved and gaseous O2 and CO2 are summed, the changes in Total O2 and CO2 are in relatively close agreement when NaHCO3 is the carbon source. These findings disprove an assumption made in some of Taub's earlier research that aquatic CESs would remain at approximately atmospheric pressure because approximately equal molar quantities of O2 and CO2 would exchange during photosynthesis and respiration; this assumption neglected the distribution of O2 between water and gas phases. High pressures can occur when NaHCO3 is the carbon source in nutrient rich media and if head-gas volumes are small relative to the liquid volume; e.g., one "worse case" condition developed 800 mm Hg above atmospheric pressure and broke the glass container. Plastic screw cap closures are likely to leak at high pressures and should not be assumed to seal unless tested at appropriate pressures. Pressure can be reduced by having larger head-gas volumes and using less concentrated nutrient solutions. It is important that pressure changes be considered for both safety and closure, and if total O2 is used as the measure of net photosynthesis and respiration, the O2 in the gas phase must be added to the dissolved O2.
NASA Astrophysics Data System (ADS)
Liu, Q.; Lange, R.
2003-12-01
Ferric iron is an important component in magmatic liquids, especially in those formed at subduction zones. Although it has long been known that Fe3+ occurs in four-, five- and six-fold coordination in crystalline compounds, only recently have all three Fe3+ coordination sites been confirmed in silicate glasses utilizing XANES spectroscopy at the Fe K-edge (Farges et al., 2003). Because the density of a magmatic liquid is largely determined by the geometrical packing of its network-forming cations (e.g., Si4+, Al3+, Ti4+, and Fe3+), the capacity of Fe3+ to undergo composition-induced coordination change affects the partial molar volume of the Fe2O3 component, which must be known to calculate how the ferric-ferrous ratio in magmatic liquids changes with pressure. Previous work has shown that the partial molar volume of Fe2O3 (VFe2O3) varies between calcic vs. sodic silicate melts (Mo et al., 1982; Dingwell and Brearley, 1988; Dingwell et al., 1988). The purpose of this study is to extend the data set in order to search for systematic variations in VFe2O3 with melt composition. High temperature (867-1534° C) density measurements were performed on eleven liquids in the Na2O-Fe2O3-FeO-SiO2 (NFS) system and five liquids in the K2O-Fe2O3-FeO-SiO2 (KFS) system using Pt double-bob Archimedean method. The ferric-ferrous ratio in the sodic and potassic liquids at each temperature of density measurement were calculated from the experimentally calibrated models of Lange and Carmichael (1989) and Tangeman et al. (2001) respectively. Compositions range (in mol%) from 4-18 Fe2O3, 0-3 FeO, 12-39 Na2O, 25-37 K2O, and 43-78 SiO2. Our density data are consistent with those of Dingwell et al. (1988) on similar sodic liquids. Our results indicate that for all five KFS liquids and for eight of eleven NFS liquids, the partial molar volume of the Fe2O3 component is a constant (41.57 ñ 0.14 cm3/mol) and exhibits zero thermal expansivity (similar to that for the SiO2 component). This value was obtained in a fit to a linear volume equation in which the other oxide components have the following fitted partial molar volumes (cm3/mol) at 1100° C: SiO2 = 26.85+/-0.04, Na2O = 26.57+/-0.07, K2O = 42.34+/-0.10, and FeO = 12.84+/-0.28, and the following fitted fitted partial molar thermal expansivities (10-3 cm3/mol-K): Na2O = 7.73+/-0.12, K2O = 11.99+/-0.24, and FeO = 2.88+/-1.22. For the three sodic liquids not included in this regression, the most iron-rich (18.2 mol% Fe2O3) has a value for VFe2O3 of 44.1 cm3/mole, whereas the most iron-poor (4.4 mol% Fe2O3) has a value for VFe2O3 of 37.0 cm3/mole. This trend may reflect a greater proportion of four-fold ferric iron in iron-rich liquids, which mirrors the trend of increasing ferric-ferrous ratios in sodic liquids as a function of total iron content (Lange and Carmichael, 1989). The most polymerized liquid in our data set was a sodic liquid that has a value for VFe2O3 of 45.0 cm3/mole. It thus appears that most (13 of 16) of our experimental liquids, which span a wide compositional range, lead to a VFe2O3 (41.6 cm3/mol) which is constant with composition and temperature. However, there are three important outliers that may have implications for the appropriate value to apply to magmatic liquids.
NASA Astrophysics Data System (ADS)
Kiriktaş, Halit; Şahin, Mehmet; Eslek, Sinan; Kiriktaş, İrem
2018-05-01
This study aims to design a mechanism with which the density of any solid or liquid can be determined without measuring its mass and volume in order to help students comprehend the concept of density more easily. The solidensimeter comprises of two scaled and nested glass containers (graduated cylinder or beaker) and sufficient water. In this method, the density measurement was made using the Archimedes’ principle stating that an object fully submerged in a liquid displaces the same amount of liquid as its volume, while an object partially submerged or floating displaces the same amount of liquid as its mass. Using this method, the density of any solids or liquids can be determined using a simple mathematical ratio. At the end of the process a mechanism that helps students to comprehend the density topic more easily was designed. The system is easy-to-design, uses low-cost equipment and enables one to determine the density of any solid or liquid without measuring its mass and volume.
A practical and sensitive method to assess volatile organic compounds (VOCs) from JP-8 jet fuel in human whole blood was developed by modifying previously established liquid-liquid extraction procedures, optimizing extraction times, solvent volume, specific sample processing te...
Transdiaphragmatic transport of tracer albumin from peritoneal to pleural liquid measured in rats.
Lai-Fook, Stephen J; Houtz, Pamela K; Jones, Philip D
2005-12-01
In conscious Wistar-Kyoto rats, we studied the uptake of radioactive tracer (125)I-albumin into the pleural space and circulation after intraperitoneal (IP) injections with 1 or 5 ml of Ringer solution (3 g/dl albumin). Postmortem, we sampled pleural liquid, peritoneal liquid, and blood plasma 2-48 h after IP injection and measured their radioactivity and protein concentration. Tracer concentration was greater in pleural liquid than in plasma approximately 3 h after injection with both IP injection volumes. This behavior indicated transport of tracer through the diaphragm into the pleural space. A dynamic analysis of the tracer uptake with 5-ml IP injections showed that at least 50% of the total pleural flow was via the diaphragm. A similar estimate was derived from an analysis of total protein concentrations. Both estimates were based on restricted pleural capillary filtration and unrestricted transdiaphragmatic transport. The 5-ml IP injections did not change plasma protein concentration but increased pleural and peritoneal protein concentrations from control values by 22 and 30%, respectively. These changes were consistent with a small (approximately 8%) increase in capillary filtration and a small (approximately 20%) reduction in transdiaphragmatic flow from control values, consistent with the small (3%) decrease in hydration measured in diaphragm muscle. Thus the pleural uptake of tracer via the diaphragm with the IP injections occurred by the near-normal transport of liquid and protein.
A tunable optofluidic circular liquid fiber
NASA Astrophysics Data System (ADS)
Li, Lei; Wu, Wei; Shi, Yang; Gong, Enze; Yang, Yi
2016-01-01
This paper presents a tunable optofluidic circular liquid fiber through the numerical simulation. Fiber is a significant optical device and has been widely applied on optical fiber communication. But the fiber based solid has limited tunability. Compared to solid fiber, the fiber based liquid material is relatively infrequent. Cause for the liquid optical device has more freedom tunable properties than solid counterpart, it has attracted more interest. The traditional optofluidic waveguide is designed like a sandwich in planar channel. This two-dimensional (2D) structure liquid waveguide will face huge transmission loss in the perpendicular direction of the flow streams. In this paper, a curving microchannel is designed inside the microchip to produce centrifugal effect. Two different liquids are injected into the chip by external pumps. In a particular situation, the core flow will be totally surrounded by the cladding flow. So the liquid can form an optical waveguide. Its structure is similar to an optical fiber which high refractive index (RI) liquid is core of the waveguide and the low RI liquid is cladding of the waveguide. Profit from the reconfigurability of liquid material, this liquid fiber has excellent tunability. The diameter of the core flow can be tuned in a wider range by changing the volume ratio of the flows through the finite element analysis. It is predictable that such a tunable liquid fiber may find wider applications in lab-on-a-chip systems and integrated optical devices.
Preliminary evaluation of a liquid belt radiator for space applications
NASA Technical Reports Server (NTRS)
Teagan, W. P.; Fitzgerald, K.
1984-01-01
The liquid belt radiator (LBR) is discussed. The LBR system operates either in the sensible heat mode or in the latent heat mode. Parametric analysis shows that the LBR may reduce the mass of heat pipe radiators by 70 to 90% when the LBR surface has a total emissivity in excess of 0.3. It is indicated that the diffusion pump oils easily meet this criteria with emissivities greater than 0.8. Measurements on gallium indicate that its emissivity is probably in excess of 0.3 in the solid state when small amounts of impurities are on the surface. The point design exhibits a characteristic mass of 3.1 kg/kW of power dissipation, a mass per unit prime radiating area of approximately 0.9 kg/sq ms and a total package volume of approximately 2.50 cubic m. This compares favorably with conventional technologies which have weights on the order of 4 kg/sq m.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-14
... liquidity; (5) add the Midpoint Match Volume Tier (``MPM Volume Tier'') to Footnote 3 of the Exchange's fee... add liquidity to the Exchange absent Members qualifying for additional volume tiered pricing. \\5... average daily volume (``ADV'') to EDGX, then the Member would get the current rate of $0.0001 per share...
Density calculations for silicate liquids: Reply to a Critical Comment by Ghiorso and Carmichael
NASA Astrophysics Data System (ADS)
Bottinga, Y.; Weill, D. F.; Richet, P.
1984-02-01
The analysis of the liquid silicate density model recently proposed in BOTTINGAet al. (1982) by GHIORSO and CARMICHAEL (1984) is shown to be based on a combination of unwarranted mathematical assumptions, refusal to recognize experimental and theoretical evidence for the non-linear effect of composition on liquid silicate density, and a totally unrealistic view of the accuracy with which the thermal expansion of silicate liquids can be measured. As a consequence, none of the general or specific points raised by Ghiorso and Carmichael are relevant to the issue of which of the existing calculation models ( BOTTINGA and WEILL, 1970; NELSON and CARMICHAEL, 1979; MOet al., 1982; or BOTTINGAet al., 1982, 1983) should be used. As stated in BOTTINGA, RICHET and WEILL (1983), there is a problem in using a combination of the molar volume parameters from the first three of these models because they are not mutually independent. However, the set of partial molar volumes and thermal expansion constants given in BOTTINGAet al. (1982, 1983) are internally consistent and mutually compatible. We remain firmly of the opinion that our latest model is an improvement over previous attempts because it conforms to a much wider set of observations, it incorporates a larger set of melt components, it calculates density and thermal expansion more accurately, and it points the way to one possible method of accommodating a non-linear phenomenon into a nonlinear model.
Wang, Donglin; Yang, Kun; Zhou, Yin
2016-03-20
Measuring the refractive index and volume of liquid under high pressure simultaneously is a big challenge. This paper proposed an alternative solution by combing optical coherence tomography with microscopy. An experiment for a feasibility study was carried out on polydimethylsiloxane liquid in a diamond anvil cell. The refractive index of the sample increased dramatically with pressure loaded, and the curve of pressure volume was also obtained.
A laboratory method for precisely determining the micro-volume-magnitudes of liquid efflux
NASA Technical Reports Server (NTRS)
Cloutier, R. L.
1969-01-01
Micro-volumetric quantities of ejected liquid are made to produce equal volumetric displacements of a more dense material. Weight measurements are obtained on the displaced heavier liquid and used to calculate volumes based upon the known density of the heavy medium.
40 CFR 98.393 - Calculating GHG emissions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... from each individual petroleum product and natural gas liquid using Equation MM-1 of this section... of each petroleum product or natural gas liquid “i” (metric tons). Producti = Annual volume of... only includes products ex refinery gate. For natural gas liquids, volumes shall reflect the individual...
Modified Tumescent Solution for Creating Working Space During Endoscopic Thyroidectomy.
Zhang, Li-Yong; Zhao, Wen-Xin; Wang, Bo; Yan, Shou-Yi; Wen, Jia
2018-04-01
To study the feasibility of gas-liquid mixing tumescent solution for creating a working space (WS) in endoscopic thyroidectomy (ET). A prospective study was performed on 186 patients with thyroid tumor who had undergone ET via chest and breast approach. Patients were randomly divided into 2 groups to receive traditional tumescent solution as group A and modified tumescent solution (gas-liquid mixing tumescent solution) as group B. This study compares the following surgical outcome parameters between the 2 groups, including changes of blood pressure, heart rate, and oxygen saturation before and after creating a WS, time for creating a WS, operative time, hemorrhage volume for creating a WS, overall hemorrhage volume, overall postoperative drainage volume, postoperative pain score, postoperative hospitalization, number of retrieved lymph nodes, total serum calcium, serum parathyroid hormone, and cases of transient and permanent recurrent laryngeal nerve palsy. No postoperative bleeding, permanent recurrent laryngeal nerve palsy, incision and surgical site infection, air embolism, flap injury occurred in both groups. The mean time for creating a WS and the whole operation in group B was significantly shorter than that in group A ( P < .05). There were no statistically significant differences in both groups in terms of other observation index ( P > .05). The clinical application of gas-liquid mixing tumescent solution can effectively reduce the time for creating a WS and whole operative time, and worthy of being widely used in ET as a safe and effective technique.
Using Dalton's Law of Partial Pressures to Determine the Vapor Pressure of a Volatile Liquid
ERIC Educational Resources Information Center
Hilgeman, Fred R.; Bertrand, Gary; Wilson, Brent
2007-01-01
This experiment, designed for a general chemistry laboratory, illustrates the use of Dalton's law of partial pressures to determine the vapor pressure of a volatile liquid. A predetermined volume of air is injected into a calibrated tube filled with a liquid whose vapor pressure is to be measured. The volume of the liquid displaced is greater than…
3D Analysis of Porosity in a Ceramic Coating Using X-ray Microscopy
NASA Astrophysics Data System (ADS)
Klement, Uta; Ekberg, Johanna; Kelly, Stephen T.
2017-02-01
Suspension plasma spraying (SPS) is a new, innovative plasma spray technique using a feedstock consisting of fine powder particles suspended in a liquid. Using SPS, ceramic coatings with columnar microstructures have been produced which are used as topcoats in thermal barrier coatings. The microstructure contains a wide pore size range consisting of inter-columnar spacings, micro-pores and nano-pores. Hence, determination of total porosity and pore size distribution is a challenge. Here, x-ray microscopy (XRM) has been applied for describing the complex pore space of the coatings because of its capability to image the (local) porosity within the coating in 3D at a resolution down to 50 nm. The possibility to quantitatively segment the analyzed volume allows analysis of both open and closed porosity. For an yttria-stabilized zirconia coating with feathery microstructure, both open and closed porosity were determined and it could be revealed that 11% of the pore volumes (1.4% of the total volume) are closed pores. The analyzed volume was reconstructed to illustrate the distribution of open and closed pores in 3D. Moreover, pore widths and pore volumes were determined. The results on the complex pore space obtained by XRM are discussed in connection with other porosimetry techniques.
NASA Technical Reports Server (NTRS)
Ohsaka, K.; Chung, S. K.; Rhim, W. K.
1997-01-01
The specific volumes and viscosities of the Ni-Zr liquid alloys as a function of temperature are determined by employing a digitizing technique and numeric analysis methods applied to the optical images of the electrostatically levitated liquid alloys.
40 CFR 799.2155 - Commercial hexane.
Code of Federal Regulations, 2010 CFR
2010-07-01
...,” for purposes of this section, is a product obtained from crude oil, natural gas liquids, or petroleum... (ASTM D 1836), consists primarily of six-carbon alkanes or cycloalkanes, and contains at least 40 liquid volume percent n-hexane (CAS No. 110-54-3) and at least 5 liquid volume percent methylcyclopentane (MCP...
40 CFR 98.393 - Calculating GHG emissions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... emissions from each individual petroleum product and natural gas liquid using Equation MM-1 of this section... of each petroleum product or natural gas liquid “i” (metric tons). Producti = Annual volume of... reported under § 98.396(a)(1). For natural gas liquids, volumes shall reflect the individual components of...
40 CFR 98.393 - Calculating GHG emissions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... emissions from each individual petroleum product and natural gas liquid using Equation MM-1 of this section... of each petroleum product or natural gas liquid “i” (metric tons). Producti = Annual volume of... reported under § 98.396(a)(2). For natural gas liquids, volumes shall reflect the individual components of...
40 CFR 98.393 - Calculating GHG emissions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... emissions from each individual petroleum product and natural gas liquid using Equation MM-1 of this section... of each petroleum product or natural gas liquid “i” (metric tons). Producti = Annual volume of... reported under § 98.396(a)(1). For natural gas liquids, volumes shall reflect the individual components of...
40 CFR 98.393 - Calculating GHG emissions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... emissions from each individual petroleum product and natural gas liquid using Equation MM-1 of this section... of each petroleum product or natural gas liquid “i” (metric tons). Producti = Annual volume of... reported under § 98.396(a)(1). For natural gas liquids, volumes shall reflect the individual components of...
NASA Technical Reports Server (NTRS)
El-Genk, Mohamed S.; Yang, Jae-Young
1991-01-01
The mechanisms of void formation during the cooldown and freezing of lithium coolant within the primary loop of SP-100 type systems are investigated. These mechanisms are: (1) homogeneous nucleation; (2) heterogeneous nucleation; (3) normal segregation of helium gas dissolved in liquid lithium; and (4) shrinkage of lithium during freezing. To evaluate the void formation potential due to segregation, a numerical scheme that couples the freezing and mass diffusion processes in both the solid and liquid regions is developed. The results indicated that the formation of He bubbles is unlikely by either homogeneous or heterogeneous nucleation during the cooldown process. However, homogeneous nucleation of He bubbles following the segregation of dissolved He in liquid lithium ahead of the solid-liquid interface is likely to occur. Results also show that total volume of He void is insignificant when compared to that of shrinkage voids. In viewing this, the subsequent research focuses on the effects of shrinkage void forming during freezing of lithium on subsequent thaw processes are investigated using a numerical scheme that is based on a single (solid/liquid) cell approach. The cases of lithium-fluoride are also investigated to show the effect of larger volume shrinkage upon freezing on the freeze and thaw processes. Results show that a void forming at the wall appreciably reduces the solid-liquid interface velocity, during both freeze and thaw, and causes a substantial rise in the wall temperature during thaw. However, in the case of Li, the maximum wall temperature was much lower than the melting temperature of PWC-11, which is used as the structure material in the SP-100 system. Hence, it is included that a formation of hot spots is unlikely during the startup or restart of the SP-100 system.
NASA Astrophysics Data System (ADS)
Kuiper, S.; Hendriks, B. H. W.; Hayes, R. A.; Feenstra, B. J.; Baken, J. M. E.
2005-09-01
Electrowetting is electrostatic manipulation of liquids. It can be used to displace and deform volumes of polar liquids. A very promising application area is optics. The surface of a volume of liquid can be used as a tunable lens and displacement of the liquid can change the refraction, diffraction or transmission of light when passing through the liquid. In this paper we describe a selection of various tunable optical components that make use of electrowetting, ranging from refractive and diffractive lenses to diaphragms and displays.
Blumenschein, Nicholas A; Han, Daewoo; Caggioni, Marco; Steckl, Andrew J
2014-06-11
Magnetic beads (MBs) with ∼1.9 μm average diameter were used to transport specific microliter-scale volumes of liquids between adjacent reservoirs within a closed tube under the influence of a magnetic field. The tube's inner surface is coated with a hydrophobic layer, enabling the formation of a surface tension valve by inserting an air gap between reservoirs. This transfer process was implemented by keeping the MBs stationary with a fixed external magnet while the liquid reservoirs were translated by a computer-controlled syringe pump system. The magnet induces the aggregation of MBs in a loosely packed cluster (void volume ∼90-95%) against the tube's inner wall. The liquid trapped in the MB cluster is transported across the air gap between reservoirs. Fluorescence intensity from a dye placed in one reservoir is used to measure the volume of liquid transferred between reservoirs. The carry-over liquid volume is controlled by the mass of the MBs within the device. The typical volume of liquid carried by the MB cluster is ∼2 to 3 μL/mg of beads, allowing the use of small samples. This technique can be used to study the effect of small compositional variation on the properties of fluid mixtures. The feasibility of this "lab-in-tube" approach for binary phase diagram determination in a water-surfactant (C12E5) system was demonstrated.
NASA Astrophysics Data System (ADS)
Kidnay, A. J.; Miller, R. C.; Sloan, E. D.; Hiza, M. J.
1985-07-01
The available experimental data for vapor-liquid equilibria, heat of mixing, change in volume on mixing for liquid mixtures, and gas-phase PVT measurements for nitrogen+methane have been reviewed and where possible evaluated for consistency. The derived properties chosen for analysis and correlation were liquid mixture excess Gibbs free energies, and Henry's constants.
Optical Mass Gauging System for Measuring Liquid Levels in a Reduced Gravity Environment
NASA Technical Reports Server (NTRS)
Sullenberger, Ryan M.; Munoz, Wesley M.; Lyon, Matt P.; Vogel, Kenny; Yalin, Azer P.; Korman, Valentin; Polzin, Kurt A.
2010-01-01
A compact and rugged fiber-coupled liquid volume sensor designed for flight on a sounding rocket platform is presented. The sensor consists of a Mach-Zehnder interferometer capable of measuring the amount of liquid contained in a tank under any gravitational conditions, including a microgravity environment, by detecting small changes in the index of refraction of the gas contained within a sensing region. By monitoring changes in the interference fringe pattern as the system undergoes a small compression provided by a piston, the ullage volume of a tank can be directly measured allowing for a determination of the liquid volume. To demonstrate the technique, data are acquired using two tanks containing different volumes of liquid, which are representative of the levels of liquid in a tank at different time periods during a mission. The two tanks are independently exposed to the measurement apparatus, allowing for a determination of the liquid level in each. In a controlled, laboratory test of the unit, the system demonstrated a capability of measuring a liquid level in an individual tank of 10.53 mL with a 2% error. The overall random uncertainty for the flight system is higher than that one test, at +/- 1.5 mL.
Measurement of gastric meal and secretion volumes using magnetic resonance imaging
NASA Astrophysics Data System (ADS)
Hoad, C. L.; Parker, H.; Hudders, N.; Costigan, C.; Cox, E. F.; Perkins, A. C.; Blackshaw, P. E.; Marciani, L.; Spiller, R. C.; Fox, M. R.; Gowland, P. A.
2015-02-01
MRI can assess multiple gastric functions without ionizing radiation. However, time consuming image acquisition and analysis of gastric volume data, plus confounding of gastric emptying measurements by gastric secretions mixed with the test meal have limited its use to research centres. This study presents an MRI acquisition protocol and analysis algorithm suitable for the clinical measurement of gastric volume and secretion volume. Reproducibility of gastric volume measurements was assessed using data from 10 healthy volunteers following a liquid test meal with rapid MRI acquisition within one breath-hold and semi-automated analysis. Dilution of the ingested meal with gastric secretion was estimated using a respiratory-triggered T1 mapping protocol. Accuracy of the secretion volume measurements was assessed using data from 24 healthy volunteers following a mixed (liquid/solid) test meal with MRI meal volumes compared to data acquired using gamma scintigraphy (GS) on the same subjects studied on a separate study day. The mean ± SD coefficient of variance between 3 observers for both total gastric contents (including meal, secretions and air) and just the gastric contents (meal and secretion only) was 3 ± 2% at large gastric volumes (>200 ml). Mean ± SD secretion volumes post meal ingestion were 64 ± 51 ml and 110 ± 40 ml at 15 and 75 min, respectively. Comparison with GS meal volumes, showed that MRI meal only volume (after correction for secretion volume) were similar to GS, with a linear regression gradient ± std err of 1.06 ± 0.10 and intercept -11 ± 24 ml. In conclusion, (i) rapid volume acquisition and respiratory triggered T1 mapping removed the requirement to image during prolonged breath-holds (ii) semi-automatic analysis greatly reduced the time required to derive measurements and (iii) correction for secretion volumes provided accurate assessment of gastric meal volumes and emptying. Together these features provide the scientific basis of a protocol which would be suitable in clinical practice.
Sereshti, Hassan; Samadi, Soheila; Jalali-Heravi, Mehdi
2013-03-08
Ultrasound assisted extraction (UAE) followed by dispersive liquid-liquid microextraction (DLLME) was used for extraction and preconcentration of volatile constituents of six tea plants. The preconcentrated compounds were analyzed by gas chromatography-mass spectrometry (GC-MS). Totally, 42 compounds were identified and caffeine was quantitatively determined. The main parameters (factors) of the extraction process were optimized by using a central composite design (CCD). Methanol and chloroform were selected as the extraction solvent and preconcentration solvent, respectively .The optimal conditions were obtained as 21 in for sonication time; 32°C for temperature; 27 L for volume of extraction solvent and 7.4% for salt concentration (NaCl/H(2)O). The determination coefficient (R(2)) was 0.9988. The relative standard deviation (RSD %) was 4.8 (n=5), and the enhancement factors (EFs) were 4.0-42.6. Copyright © 2013 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
VanCleave, Janice
2000-01-01
Describes a science activity in which students make a non-Newtonian fluid (slime), which has both solid and liquid properties. After reviewing the shape and volume of solids and volume of liquids, students make the slime using glue, liquid starch, and food coloring. They can experiment by rolling and dropping slime balls and by pulling the slime…
Preservation of Liquid Biological Samples
NASA Technical Reports Server (NTRS)
Putcha, Lakshmi (Inventor); Nimmagudda, Ramalingeshwara R. (Inventor)
2000-01-01
The present invention provides a method of preserving a liquid biological sample, comprising the step of: contacting said liquid biological sample with a preservative comprising, sodium benzoate in an amount of at least about 0.15% of the sample (weight/volume) and citric acid in an amount of at least about 0.025% of the sample (weight/volume).
A microphysical parameterization of aqSOA and sulfate formation in clouds
NASA Astrophysics Data System (ADS)
McVay, Renee; Ervens, Barbara
2017-07-01
Sulfate and secondary organic aerosol (cloud aqSOA) can be chemically formed in cloud water. Model implementation of these processes represents a computational burden due to the large number of microphysical and chemical parameters. Chemical mechanisms have been condensed by reducing the number of chemical parameters. Here an alternative is presented to reduce the number of microphysical parameters (number of cloud droplet size classes). In-cloud mass formation is surface and volume dependent due to surface-limited oxidant uptake and/or size-dependent pH. Box and parcel model simulations show that using the effective cloud droplet diameter (proportional to total volume-to-surface ratio) reproduces sulfate and aqSOA formation rates within ≤30% as compared to full droplet distributions; other single diameters lead to much greater deviations. This single-class approach reduces computing time significantly and can be included in models when total liquid water content and effective diameter are available.
A Variational Statistical-Field Theory for Polar Liquid Mixtures
NASA Astrophysics Data System (ADS)
Zhuang, Bilin; Wang, Zhen-Gang
Using a variational field-theoretic approach, we derive a molecularly-based theory for polar liquid mixtures. The resulting theory consists of simple algebraic expressions for the free energy of mixing and the dielectric constant as functions of mixture composition. Using only the dielectric constants and the molar volumes of the pure liquid constituents, the theory evaluates the mixture dielectric constants in good agreement with the experimental values for a wide range of liquid mixtures, without using adjustable parameters. In addition, the theory predicts that liquids with similar dielectric constants and molar volumes dissolve well in each other, while sufficient disparity in these parameters result in phase separation. The calculated miscibility map on the dielectric constant-molar volume axes agrees well with known experimental observations for a large number of liquid pairs. Thus the theory provides a quantification for the well-known empirical ``like-dissolves-like'' rule. Bz acknowledges the A-STAR fellowship for the financial support.
Methods to control phase inversions and enhance mass transfer in liquid-liquid dispersions
Tsouris, Constantinos; Dong, Junhang
2002-01-01
The present invention is directed to the effects of applied electric fields on liquid-liquid dispersions. In general, the present invention is directed to the control of phase inversions in liquid-liquid dispersions. Because of polarization and deformation effects, coalescence of aqueous drops is facilitated by the application of electric fields. As a result, with an increase in the applied voltage, the ambivalence region is narrowed and shifted toward higher volume fractions of the dispersed phase. This permits the invention to be used to ensure that the aqueous phase remains continuous, even at a high volume fraction of the organic phase. Additionally, the volume fraction of the organic phase may be increased without causing phase inversion, and may be used to correct a phase inversion which has already occurred. Finally, the invention may be used to enhance mass transfer rates from one phase to another through the use of phase inversions.
Process for the production of liquid hydrocarbons
Bhatt, Bharat Lajjaram; Engel, Dirk Coenraad; Heydorn, Edward Clyde; Senden, Matthijis Maria Gerardus
2006-06-27
The present invention concerns a process for the preparation of liquid hydrocarbons which process comprises contacting synthesis gas with a slurry of solid catalyst particles and a liquid in a reactor vessel by introducing the synthesis gas at a low level into the slurry at conditions suitable for conversion of the synthesis gas into liquid hydrocarbons, the solid catalyst particles comprising a catalytic active metal selected from cobalt or iron on a porous refractory oxide carrier, preferably selected from silica, alumina, titania, zirconia or mixtures thereof, the catalyst being present in an amount between 10 and 40 vol. percent based on total slurry volume liquids and solids, and separating liquid material from the solid catalyst particles by using a filtration system comprising an asymmetric filtration medium (the selective side at the slurry side), in which filtration system the average pressure differential over the filtration medium is at least 0.1 bar, in which process the particle size distribution is such that at least a certain amount of the catalyst particles is smaller than the average pore size of the selective layer of the filtration medium. The invention also comprises an apparatus to carry out the process described above.
Method and apparatus for electrokinetic transport
NASA Technical Reports Server (NTRS)
James, Patrick Ismail (Inventor); Stejic, George (Inventor)
2012-01-01
Controlled electrokinetic transport of constituents of liquid media can be achieved by connecting at least two volumes containing liquid media with at least one dielectric medium with opposing dielectric surfaces in direct contact with said liquid media, and establishing at least one conduit across said dielectric medium, with a conduit inner surface surrounding a conduit volume and at least a first opening and a second opening opposite to the first opening. The conduit is arranged to connect two volumes containing liquid media and includes a set of at least three electrodes positioned in proximity of the inner conduit surface. A power supply is arranged to deliver energy to the electrodes such that time-varying potentials inside the conduit volume are established, where the superposition of said potentials represents at least one controllable traveling potential well that can travel between the opposing conduit openings.
Numerical modelling of multiphase liquid-vapor-gas flows with interfaces and cavitation
NASA Astrophysics Data System (ADS)
Pelanti, Marica
2017-11-01
We are interested in the simulation of multiphase flows where the dynamical appearance of vapor cavities and evaporation fronts in a liquid is coupled to the dynamics of a third non-condensable gaseous phase. We describe these flows by a single-velocity three-phase compressible flow model composed of the phasic mass and total energy equations, the volume fraction equations, and the mixture momentum equation. The model includes stiff mechanical and thermal relaxation source terms for all the phases, and chemical relaxation terms to describe mass transfer between the liquid and vapor phases of the species that may undergo transition. The flow equations are solved by a mixture-energy-consistent finite volume wave propagation scheme, combined with simple and robust procedures for the treatment of the stiff relaxation terms. An analytical study of the characteristic wave speeds of the hierarchy of relaxed models associated to the parent model system is also presented. We show several numerical experiments, including two-dimensional simulations of underwater explosive phenomena where highly pressurized gases trigger cavitation processes close to a rigid surface or to a free surface. This work was supported by the French Government Grant DGA N. 2012.60.0011.00.470.75.01, and partially by the Norwegian Grant RCN N. 234126/E30.
Core body temperature control by total liquid ventilation using a virtual lung temperature sensor.
Nadeau, Mathieu; Micheau, Philippe; Robert, Raymond; Avoine, Olivier; Tissier, Renaud; Germim, Pamela Samanta; Vandamme, Jonathan; Praud, Jean-Paul; Walti, Herve
2014-12-01
In total liquid ventilation (TLV), the lungs are filled with a breathable liquid perfluorocarbon (PFC) while a liquid ventilator ensures proper gas exchange by renewal of a tidal volume of oxygenated and temperature-controlled PFC. Given the rapid changes in core body temperature generated by TLV using the lung has a heat exchanger, it is crucial to have accurate and reliable core body temperature monitoring and control. This study presents the design of a virtual lung temperature sensor to control core temperature. In the first step, the virtual sensor, using expired PFC to estimate lung temperature noninvasively, was validated both in vitro and in vivo. The virtual lung temperature was then used to rapidly and automatically control core temperature. Experimentations were performed using the Inolivent-5.0 liquid ventilator with a feedback controller to modulate inspired PFC temperature thereby controlling lung temperature. The in vivo experimental protocol was conducted on seven newborn lambs instrumented with temperature sensors at the femoral artery, pulmonary artery, oesophagus, right ear drum, and rectum. After stabilization in conventional mechanical ventilation, TLV was initiated with fast hypothermia induction, followed by slow posthypothermic rewarming for 1 h, then by fast rewarming to normothermia and finally a second fast hypothermia induction phase. Results showed that the virtual lung temperature was able to provide an accurate estimation of systemic arterial temperature. Results also demonstrate that TLV can precisely control core body temperature and can be favorably compared to extracorporeal circulation in terms of speed.
Scala, Christopher; Marsot, Amélie; Limoges, Marie-Josée; Locatelli, Yann; Simon, Nicolas; Alvarez, Jean-Claude
2015-03-01
To assess the population pharmacokinetics of methadone in deer. Prospective non-randomized experimental trial. Twelve healthy adult sika deer (nine males and three females). Deer received intramuscular administration of racemic methadone hydrochloride at 0.5 mg kg(-1) or 1 mg kg(-1) . Plasma methadone and its metabolite 2-Ethylidene-1,5-Dimethyl-3,3-Diphenyl-Pyrolidine (EDDP) concentrations were determined by validated liquid chromatography coupled to tandem mass spectrometry methods, at times 0, 30 minutes, 1, 2, 3, 4, 5, 6, 8, 12 and 24 hours. Population pharmacokinetics analysis was undertaken using a non-linear mixed effects modelling (NONMEM). A two-compartment linear disposition model best described observed time-concentration profiles of methadone and EDDP. Population parameter estimates of methadone were elimination clearance (17.3 L hour(-1) ), metabolic clearance (34.6 L hour(-1) ), volume of distribution of compartment 1 (216.0 L) and volume of distribution of compartment 2 (384.0 L). Population parameter estimates of EDDP were elimination clearance (121.0 L hour(-1) ), volume of distribution of compartment 3 (1.08 L) and volume of distribution of compartment 4 (499.5 L). The total clearance and total volume of distribution of methadone and EDDP were 51.9 L hour(-1) , 121.0 L hour (-1) , 600.0 L and 500.6 L, respectively. The methadone terminal elimination half-life was 8.19 hours. No adverse effects were observed after methadone administration. Following intramuscular injection, methadone was characterized by a large total volume of distribution, high systemic clearance and intermediate terminal half-life in sika deer. © 2014 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.
Single and two-phase flows of shear-thinning media in safety valves.
Moncalvo, D; Friedel, L
2009-09-15
This study is the first one in the scientific literature to investigate the liquid and two-phase flows of shear-thinning media, here aqueous solutions of polyvinylpyrrolidone, in a fully opened safety valve. In liquid flows the volume flux at the valve seat does not show any appreciable reduction when increasing the percental weight of polymer in the solution. This result may suggest that the viscous losses in the valve do not increase sensibly from the most aqueous to the most viscous solution. The authors explain it considering that in the region between the seat and the disk, where large pressure and velocity gradients occur, large shear rates are expected. On behalf of the rheological measurements, which show that both the pseudoplasticity and the zero-shear viscosity of the solutions increase with the polymer weight, the difference between the viscosities of the most viscous and those of the most aqueous solution is between the seat and the disk far less than that existing at zero-shear condition. Therefore, the effective viscous pressure drop of the safety valve, which occurs mostly in that region, must increase only modestly with the polymer percental weight in the solution. In two-phase flows the total mass flow rate at constant quality and constant relieving pressure increases remarkably with the polymer weight. The analogy with similar results in cocurrent pipe flows suggests that air entrainment causes large velocity gradients in the liquids and strains them to very large shear rates. It suggests also that a redistribution of the gas agglomerates within the liquid must be expected when increasing the polymer weight in the solutions. In fact, the gas agglomerates react to the larger viscous drag of the liquid by compressing their volume in order to exert a higher internal pressure. The reduction of the void fraction of the mixture at constant quality and constant relieving pressure imposes an increment in the total mass flow rate, since otherwise it would lead to a reduction in the momentum of the mixture and therefore to a drop in the relieving pressure.
3-D Numerical Simulation for Gas-Liquid Two-Phase Flow in Aeration Tank
NASA Astrophysics Data System (ADS)
Xue, R.; Tian, R.; Yan, S. Y.; Li, S.
In the crafts of activated sludge treatment, oxygen supply and the suspending state of activated sludge are primary factors to keep biochemistry process carrying on normally. However, they are all controlled by aeration. So aeration is crucial. The paper focus on aeration, use CFD software to simulate the field of aeration tank which is designed by sludge load method. The main designed size of aeration tank is: total volume: 20 000 m3; corridor width: 8m; total length of corridors: 139m; number of corridors: 3; length of one single corridor: 48m; effective depth: 4.5m; additional depth: 0.5m. According to the similarity theory, a geometrical model is set up in proportion of 10:1. The way of liquid flow is submerge to avoid liquid flow out directly. The grid is plotted by dividing the whole computational area into two parts. The bottom part which contains gas pipe and gas exit hole and the above part which is the main area are plotted by tetrahedron and hexahedron respectively. In boundary conditions, gas is defined as the primary-phase, and liquid is defined as the secondary-phase. Choosing mixture model, two-phase flow field of aeration tank is simulated by solved the Continuity equation for the mixture, Momentum equation for the mixture, Volume fraction equation for the secondary phases and Relative velocity formula when gas velocity is 10m/s, 20m/s, 30m/s. what figure shows is the contour of velocity magnitude for the mixture phase when gas velocity is 20m/s. Through analysis, the simulation tendency is agreed with actual running of aeration tank. It is feasible to use mixture model to simulate flow field of aeration tank by fluent software. According to the simulation result, the better velocity of liquid or gas (the quantity of inlet air) can be chosen by lower cost, and also the performance of aeration tank can be forecast. It will be helpful for designing and operation.
Hao, Tian
2015-09-14
The underlying relationships among viscosity equations of glass liquids and colloidal suspensions are explored with the aid of free volume concept. Viscosity equations of glass liquids available in literature are focused and found to have a same physical basis but different mathematical expressions for the free volume. The glass transitions induced by temperatures in glass liquids and the percolation transition induced by particle volume fractions in colloidal suspensions essentially are a second order phase transition: both those two transitions could induce the free volume changes, which in turn determines how the viscosities are going to change with temperatures and/or particle volume fractions. Unified correlations of the free volume to both temperatures and particle volume fractions are thus proposed. The resulted viscosity equations are reducible to many popular viscosity equations currently widely used in literature; those equations should be able to cover many different types of materials over a wide temperature range. For demonstration purpose, one of the simplified versions of those newly developed equations is compared with popular viscosity equations and the experimental data: it can well fit the experimental data over a wide temperature range. The current work reveals common physical grounds among various viscosity equations, deepening our understanding on viscosity and unifying the free volume theory across many different systems.
Eigenmode multiplexing with SLM for volume holographic data storage
NASA Astrophysics Data System (ADS)
Chen, Guanghao; Miller, Bo E.; Takashima, Yuzuru
2017-08-01
The cavity supports the orthogonal reference beam families as its eigenmodes while enhancing the reference beam power. Such orthogonal eigenmodes are used as additional degree of freedom to multiplex data pages, consequently increase storage densities for volume Holographic Data Storage Systems (HDSS) when the maximum number of multiplexed data page is limited by geometrical factor. Image bearing holograms are multiplexed by orthogonal phase code multiplexing via Hermite-Gaussian eigenmodes in a Fe:LiNbO3 medium with a 532 nm laser at multiple Bragg angles by using Liquid Crystal on Silicon (LCOS) spatial light modulators (SLMs) in reference arms. Total of nine holograms are recorded with three angular and three eigenmode.
Acoustically-Enhanced Direct Contact Vapor Bubble Condensation
NASA Astrophysics Data System (ADS)
Boziuk, Thomas; Smith, Marc; Glezer, Ari
2017-11-01
Rate-limited, direct contact vapor condensation of vapor bubbles that are formed by direct steam injection through a nozzle in a quiescent subcooled liquid bath is accelerated using ultrasonic (MHz-range) actuation. A submerged, low power actuator produces an acoustic beam whose radiation pressure deforms the liquid-vapor interface, leading to the formation of a liquid spear that penetrates the vapor bubble to form a vapor torus with a significantly larger surface area and condensation rate. Ultrasonic focusing along the spear leads to the ejection of small, subcooled droplets through the vapor volume that impact the vapor-liquid interface and further enhance the condensation. High-speed Schlieren imaging of the formation and collapse of the vapor bubbles in the absence and presence of actuation shows that the impulse associated with the collapse of the toroidal volume leads to the formation of a turbulent vortex ring in the liquid phase. Liquid motions near the condensing vapor volume are investigated in the absence and presence of acoustic actuation using high-magnification PIV and show the evolution of a liquid jet through the center of the condensing toroidal volume and the formation and advection of vortex ring structures whose impulse appear to increase with temperature difference between the liquid and vapor phases. High-speed image processing is used to assess the effect of the actuation on the temporal and spatial variations in the characteristic scales and condensation rates of the vapor bubbles.
Research on Volume Measurement System of Weights with Hydrostatic Technique
NASA Astrophysics Data System (ADS)
Wang, Jian; Ren, Xiaoping; Yao, Hong; Cai, Changqing; Zhang, Yue; Zhong, Ruilin; Ding, Jing'an
According to Annex B.7.4 of OIML R111-1, equipment for measuring volume of weights mass ranging from 1 kg to 20 kg including three methods of hydrostatic comparison is described. The equipment consists of a robot arm for transferring weights, a liquid bath, a mass comparator with 26.1 kg of maximum capacity and 1 mg of readability, glass housing, two weight exchangers including in air and in liquid, two weight holders including in air and in liquid, and a controller. The equipment will enable to perform automatically volume measurements.
Improved OCT imaging of lung tissue using a prototype for total liquid ventilation
NASA Astrophysics Data System (ADS)
Schnabel, Christian; Meissner, Sven; Koch, Edmund
2011-06-01
Optical coherence tomography (OCT) is used for imaging subpleural alveoli in animal models to gain information about dynamic and morphological changes of lung tissue during mechanical ventilation. The quality of OCT images can be increased if the refraction index inside the alveoli is matched to the one of tissue via liquid-filling. Thereby, scattering loss can be decreased and higher penetration depth and tissue contrast can be achieved. Until now, images of liquid-filled lungs were acquired in isolated and fixated lungs only, so that an in vivo measurement situation is not present. To use the advantages of liquid-filling for in vivo imaging of small rodent lungs, it was necessary to develop a liquid ventilator. Perfluorodecalin, a perfluorocarbon, was selected as breathing fluid because of its refraction index being similar to the one of water and the high transport capacity for carbon dioxide and oxygen. The setup is characterized by two independent syringe pumps to insert and withdraw the fluid into and from the lung and a custom-made control program for volume- or pressure-controlled ventilation modes. The presented results demonstrate the liquid-filling verified by optical coherence tomography and intravital microscopy (IVM) and the advantages of liquid-filling to OCT imaging of subpleural alveoli.
Radwaste desk reference - Volume 3, Part 2: Liquid waste management. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deltete, D.; Fisher, S.; Kelly, J.J.
1994-05-01
EPRI began, in late in 1987, to produce a Radwaste Desk Reference that would allow each of the member utilities access to the available information and expertise on radwaste management. EPRI considers this important because radwaste management involves a wide variety of scientific and engineering disciplines. These include chemical and mechanical engineering, chemistry, and health physics. Radwaste management also plays a role in implementing a wide variety of regulatory requirements. These include plant-specific technical specifications, NRC standards for protection against radiation, DOT transportation regulations and major environmental legislation such as the Resource Conservation and Recovery Act. EPRI chose a questionmore » and answer format because it could be easily accessed by radwaste professionals with a variety of interests. The questions were generated at two meetings of utility radwaste professionals and EPRI contractors. Volume 1, which is already in publication, addresses dry active waste generation, processing and measurement. Volume 2 addresses low level waste storage, transportation and disposal. This volume, Volume 3, is being issued in two parts. Part 1 concentrates on the processing of liquid radioactive waste, whereas Part 2, included here, addresses liquid waste management. It includes extensive information and operating practices related to liquid waste generation and control, liquid waste processing systems at existing U.S. nuclear plants, processes for managing wet wastes (handling, dewatering, solidifying, processing, and packaging), and liquid waste measurement and analysis.« less
Leidenfrost phenomenon on conical surfaces
NASA Astrophysics Data System (ADS)
Hidalgo-Caballero, S.; Escobar-Ortega, Y.; Pacheco-Vázquez, F.
2016-09-01
The Leidenfrost state is typically studied by placing droplets on flat or slightly curved surfaces. Here this phenomenon is investigated by depositing water in hot conical bowls. We found that this phase exists even for large amounts of liquid in very narrow cones without considerable effect of the confinement on the Leidenfrost transition temperature TL. At a fixed temperature, T >TL , the total evaporation time τ has a nonmonotonic dependence on the angle of confinement θ : for large volumes (˜20 ml) on flat surfaces (θ ˜0∘ ), vapor chimneys appear and accelerate the evaporation rate, their frequency diminishes as θ augments and becomes zero at a certain angle θc, at which τ reaches its maximum value; then, τ decreases again at larger angles because the vapor layer holding up the water becomes thinner due to the increase of hydrostatic pressure and because the geometry facilitates the vapor expulsion along the conical wall. For small volumes (˜1 ml), surface tension mainly determines the drop curvature and the lifetime is practically independent of θ . Different chimney regimes and oscillation patterns were observed and summarized in a phase diagram. Finally, we developed a simple model to decipher the shape adopted by the liquid volume and its evolution as a function of time, and the predictions are in good agreement with the experimental results.
NASA Astrophysics Data System (ADS)
Fathy, Naglaa; Ramadan, Mohamed
2018-05-01
The influence of volume ratio of liquid to Solid and low pouring temperature on interface structure of cast Babbitt-steel bimetal composite was evaluated for static casting technique. At low pouring temperature of 380 °C, Babbitt microstructures are improved to be finer and more globular. On the other side pouring the Babbitt at low pouring temperature of 380 °C increases the chance of present higher unbonded area percent. Increasing the volume ratio of liquid to solid decreases the Sn-Pb interface thicknesses and increases the bonded interface area. In order to optimize the production of Babbitt-steel bimetal composite at low pouring temperature, the volume ratio of liquid Babbitt to solid steel shell should be higher value that could be more than 5 depending on the extrapolation of current data presented.
Yang, Di; Deng, Liangwei; Zheng, Dan; Wang, Lan; Liu, Yi
2016-03-01
There are two problems associated with treatment of swine wastewater, low efficiency of anaerobic digestion during winter and poor performance for aerobic treatment of digested effluent. A strategy employing unbalanced distributions of the pollutant mass and wastewater volumes in anaerobic and aerobic units was proposed. To accomplish this, swine wastewater was separated into high content liquid (HCL) and low content liquid (LCL). Three separation ratios of HCL to LCL (v/v), 1:9 (S1), 2:8 (S2), and 3:7 (S3), were evaluated. Anaerobically digestion of the HCL accounted for only 10%, 20% and 30% of the total volume of raw wastewater, but produced 63.38%, 73.79% and 76.61% of the total methane output for S1, S2 and S3, respectively. The mixed liquid of digested effluents of HCL and LCL were treated aerobically using sequencing batch reactors. S2 generated the best performance, with removal efficiencies of 96.98% for COD, 98.95% for NH3-N, 91.69% for TN and 74.71% for TP. The results obtained for S1 were not as good as those for S2, but were better than those for S3. Based on methane output from the anaerobic unit and pollutants removal in the aerobic unit, S2 was the most suitable system for the treatment of swine wastewater. Additionally, the anaerobic digestion efficiency of S2 was 282% higher than that of previous techniques employing balanced distribution. Taken together, these findings indicate that unbalanced distribution could improve the efficiency of the anaerobic unit remarkably, while ensuring good performance of the aerobic unit. Copyright © 2015. Published by Elsevier Ltd.
Catalyst for coal liquefaction process
Huibers, Derk T. A.; Kang, Chia-Chen C.
1984-01-01
An improved catalyst for a coal liquefaction process; e.g., the H-Coal Process, for converting coal into liquid fuels, and where the conversion is carried out in an ebullated-catalyst-bed reactor wherein the coal contacts catalyst particles and is converted, in addition to liquid fuels, to gas and residual oil which includes preasphaltenes and asphaltenes. The improvement comprises a catalyst selected from the group consisting of the oxides of nickel molybdenum, cobalt molybdenum, cobalt tungsten, and nickel tungsten on a carrier of alumina, silica, or a combination of alumina and silica. The catalyst has a total pore volume of about 0.500 to about 0.900 cc/g and the pore volume comprises micropores, intermediate pores and macropores, the surface of the intermediate pores being sufficiently large to convert the preasphaltenes to asphaltenes and lighter molecules. The conversion of the asphaltenes takes place on the surface of micropores. The macropores are for metal deposition and to prevent catalyst agglomeration. The micropores have diameters between about 50 and about 200 angstroms (.ANG.) and comprise from about 50 to about 80% of the pore volume, whereas the intermediate pores have diameters between about 200 and 2000 angstroms (.ANG.) and comprise from about 10 to about 25% of the pore volume, and the macropores have diameters between about 2000 and about 10,000 angstroms (.ANG.) and comprise from about 10 to about 25% of the pore volume. The catalysts are further improved where they contain promoters. Such promoters include the oxides of vanadium, tungsten, copper, iron and barium, tin chloride, tin fluoride and rare earth metals.
Omari, Taher I; Dejaeger, Eddy; Tack, Jan; Van Beckevoort, Dirk; Rommel, Nathalie
2013-06-01
Automated impedance manometry (AIM) analysis measures swallow variables defining bolus timing, pressure, contractile vigour, and bolus presence, which are combined to derive a swallow risk index (SRI) correlating with aspiration. In a heterogeneous cohort of dysphagia patients, we assessed the impact of bolus volume and viscosity on AIM variables. We studied 40 patients (average age = 46 years). Swallowing of boluses was recorded with manometry, impedance, and videofluoroscopy. AIMplot software was used to derive functional variables: peak pressure (PeakP), pressure at nadir impedance (PNadImp), time from nadir impedance to peak pressure (TNadImp-PeakP), the interval of impedance drop in the distal pharynx (flow interval, FI), upper oesophageal sphincter (UES) relaxation interval (UES RI), nadir UES pressure (Nad UESP), UES intrabolus pressure (UES IBP), and UES resistance. The SRI was derived using the formula SRI = (FI * PNadImp)/(PeakP * (TNadImp-PeakP + 1)) * 100. A total of 173 liquid, 44 semisolid, and 33 solid boluses were analysed. The SRI was elevated in relation to aspiration. PeakP increased with volume. SRI was not significantly altered by bolus volume. PNadImp, UES IBP, and UES resistance increased with viscosity. SRI was lower with increased viscosity. In patients with dysphagia, the SRI is elevated in relation to aspiration, reduced by bolus viscosity, and not affected by bolus volume. These data provide evidence that pharyngeal AIM analysis may have clinical utility for assessing deglutitive aspiration risk to liquid boluses.
Evaluation of on-board hydrogen storage methods for hypersonic vehicles
NASA Technical Reports Server (NTRS)
Akyurtlu, Ates; Akyurtlu, J. F.; Adeyiga, A. A.; Perdue, Samara; Northam, G. B.
1989-01-01
Hydrogen is the foremost candidate as a fuel for use in high speed transport. Since any aircraft moving at hypersonic speeds must have a very slender body, means of decreasing the storage volume requirements below that for liquid hydrogen are needed. The total performance of the hypersonic plane needs to be considered for the evaluation of candidate fuel and storage systems. To accomplish this, a simple model for the performance of a hypersonic plane is presented. To allow for the use of different engines and fuels during different phases of flight, the total trajectory is divided into three phases: subsonic-supersonic, hypersonic and rocket propulsion phase. The fuel fraction for the first phase is found be a simple energy balance using an average thrust to drag ratio for this phase. The hypersonic flight phase is investigated in more detail by taking small altitude increments. This approach allowed the use of flight profiles other than the constant dynamic pressure flight. The effect of fuel volume on drag, structural mass and tankage mass was introduced through simplified equations involving the characteristic dimension of the plane. The propellant requirement for the last phase is found by employing the basic rocket equations. The candidate fuel systems such as the cryogenic fuel combinations and solid and liquid endothermic hydrogen generators are first screened thermodynamically with respect to their energy densities and cooling capacities and then evaluated using the above model.
Sze, Morgan C.; Schindler, Harvey D.
1982-01-01
Coal is catalytically hydroliquefied by passing coal dispersed in a liquefaction solvent and hydrogen upwardly through a plurality of parallel expanded catalyst beds, in a single reactor, in separate streams, each having a cross-sectional flow area of no greater than 255 inches square, with each of the streams through each of the catalyst beds having a length and a liquid and gas superficial velocity to maintain an expanded catalyst bed and provide a Peclet Number of at least 3. If recycle is employed, the ratio of recycle to total feed (coal and liquefaction solvent) is no greater than 2:1, based on volume. Such conditions provide for improved selectivity to liquid product to thereby reduce hydrogen consumption. The plurality of beds are formed by partitions in the reactor.
NASA Astrophysics Data System (ADS)
Mihucz, Victor G.; Tatár, Eniko; Varga, Anita; Záray, Gyula; Cseh, Edit
2001-11-01
Total-reflection X-ray fluorescence (TXRF) spectrometry, reversed-phase (RP) and size-exclusion (SE) high-performance liquid chromatography (HPLC) methods were applied for the characterization of low-volume xylem sap of control and nickel contaminated cucumber plants growing in hydroponics containing urea as the sole nitrogen source. In these saps collected for 1 h, Ca, K, Fe, Mn, Ni, Zn, as well as malic, citric and fumaric acids were determined. The SEC measurements showed that macromolecules were not detectable in the samples. Nickel contamination had minimum impact on the organic acid transport, however, the transport of Zn, K and Fe was reduced by 50, 22 and 11%, respectively. This observation supports the results of our earlier experiments when nitrate ions were used as the sole nitrogen form. At the same time, the fresh root weight and the volume of the collected xylem sap increased by 36 and 85%, respectively. Therefore, nickel addition seemed to decrease the urea toxicity of the plants. By pooling the eluting fractions of the SEC column, which were 10-fold concentrated by freeze-drying, the series of the resulted samples were analyzed by the TXRF spectrometry and RP-HPLC. The three organic acids could be identified in only one of the fractions, which contained Fe and, in the case of the contaminated plants, Ni in detectable concentration. However, considerable parts of these two elements and Mn, as well as practically the total amounts of Cu may be transported by unidentified organic compounds in the xylem.
A molecular dynamics study of lithium-containing aprotic heterocyclic ionic liquid electrolytes
NASA Astrophysics Data System (ADS)
Lourenço, Tuanan C.; Zhang, Yong; Costa, Luciano T.; Maginn, Edward J.
2018-05-01
Classical molecular dynamics simulations were performed on twelve different ionic liquids containing aprotic heterocyclic anions doped with Li+. These ionic liquids have been shown to be promising electrolytes for lithium ion batteries. Self-diffusivities, lithium transference numbers, densities, and free volumes were computed as a function of lithium concentration. The dynamics and free volume decreased with increasing lithium concentration, and the trends were rationalized by examining the changes to the liquid structure. Of those examined in the present work, it was found that (methyloxymethyl)triethylphosphonium triazolide ionic liquids have the overall best performance.
Physical-chemical characterization of the textile dye Azo Ab52 degradation by corona plasma
NASA Astrophysics Data System (ADS)
Gómez, A.; Torres-Arenas, A. J.; Vergara-Sánchez, J.; Torres, C.; Reyes, P. G.; Martínez, H.; Saldarriaga-Noreña, Hugo
2017-10-01
This work characterizes the degradation of the textile dye azo Acid Black 52 by measuring several physical and chemical parameters. A corona plasma was created at atmospheric pressure and applied on the liquid-air interface of water samples containing the dye. 1.0 mM of ferrous sulfate (FeSO4) was added to 1.0 mM dye solution, for a total volume of 250 mL. For each treatment, a number of parameters were quantified. These were voltage, current, temperature, loss of volume, pH, electrical conductivity, concentration, optical mission spectra, chemical oxygen demand (COD), total organic carbon (TOC), and the removal ratio. Because of the increase in the sample temperature, the volume lost by evaporation was explored. The results show that the efficiency of the dye degradation by plasma is a function of treatment time. Moreover, the reactive concentration of FeSO4 and the exposition time of the plasma were varied at a constant volume, leading to the determination of the concentrations and optimal times. Considering the degradation and removal parameters, at the maximum treated time of 80 min, it found that COD was of 96.36%, TOC of 93.93%, and the removal ratio of 97.47%.
The effect of dietary supplementation of algae rich in docosahexaenoic acid on boar fertility.
Murphy, E M; Stanton, C; Brien, C O '; Murphy, C; Holden, S; Murphy, R P; Varley, P; Boland, M P; Fair, S
2017-03-01
The objective of this study was to assess the effects of dietary supplementation of a commercial algal product rich in docosahexaenoic acid (DHA) on boar fertility as assessed in vitro and in vivo. Boars were fed one of three experimental diets for 19 weeks: (i) Control (Ctl) diet (n = 31), (ii) Ctl diet plus 75g All-G-Rich per day (n = 31) or (iii) Ctl diet plus 150g All-G-Rich per day (n = 30). Parameters assessed were (i) raw semen quality; volume, sperm concentration, total motility and morphology (ii) liquid semen quality; progressive motility, viability, hypotonic resistance and acrosomal integrity (iii) frozen-thawed semen quality; motility, thermal stress, viability, membrane fluidity and mitochondrial activity (iv) sperm and seminal plasma (SP) fatty acid composition (FAC) (v) total antioxidant capacity (TAC) of SP and (vi) farrowing rates and litter sizes of sows (n = 1158) inseminated with liquid semen. Boars consuming 75g All-G-Rich had a larger semen volume (P < 0.05) and a higher total sperm number (P < 0.01) than the Ctl treatment, however, there was no effect of treatment on any other semen quality parameter (P > 0.05). There was no effect of dietary treatment on the FAC and TAC of SP or on farrowing rate and litter size (P > 0.05). There was an effect of dietary treatment on the FAC of sperm, represented by an 1.72 and 1.60 fold increase in the DHA content for 75 and 150g treatments, respectively, compared to the Ctl treatment. In conclusion, a significant increase in semen volume and total sperm number in boars supplemented 75g All-G-Rich daily, resulted in an increase in production of 3 to 4 more doses per ejaculate, thus, indicating that the feeding regime described within this study has the potential for increasing the output of boar studs. Copyright © 2016 Elsevier Inc. All rights reserved.
de Prost, Nicolas; Roux, Damien; Dreyfuss, Didier; Ricard, Jean-Damien; Le Guludec, Dominique; Saumon, Georges
2007-04-01
To evaluate whether PEEP affects intrapulmonary alveolar edema liquid movement and alveolar permeability to proteins during high volume ventilation. Experimental study in an animal research laboratory. 46 male Wistar rats. A (99m)Tc-labeled albumin solution was instilled in a distal airway to produce a zone of alveolar flooding. Conventional ventilation (CV) was applied for 30 min followed by various ventilation strategies for 3 h: CV, spontaneous breathing, and high volume ventilation with different PEEP levels (0, 6, and 8 cmH(2)O) and different tidal volumes. Dispersion of the instilled liquid and systemic leakage of (99m)Tc-albumin from the lungs were studied by scintigraphy. The instillation protocol produced a zone of alveolar flooding that stayed localized during CV or spontaneous breathing. High volume ventilation dispersed alveolar liquid in the lungs. This dispersion was prevented by PEEP even when tidal volume was the same and thus end-inspiratory pressure higher. High volume ventilation resulted in the leakage of instilled (99m)Tc-albumin from the lungs. This increase in alveolar albumin permeability was reduced by PEEP. Albumin permeability was more affected by the amplitude of tidal excursions than by overall lung distension. PEEP prevents the dispersion of alveolar edema liquid in the lungs and lessens the increase in alveolar albumin permeability due to high volume ventilation.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-14
... liquidity from the Book to pay a reduced fee of $0.0029 per share if they directly execute providing volume... liquidity from the Book to pay a reduced fee of $0.0029 per share if they directly execute providing volume... B Step Up Tier allows ETP Holders and Market Makers that take liquidity from the Book to pay a...
38th JANNAF Combustion Subcommittee Meeting. Volume 1
NASA Technical Reports Server (NTRS)
Fry, Ronald S. (Editor); Eggleston, Debra S. (Editor); Gannaway, Mary T. (Editor)
2002-01-01
This volume, the first of two volumes, is a collection of 55 unclassified/unlimited-distribution papers which were presented at the Joint Army-Navy-NASA-Air Force (JANNAF) 38th Combustion Subcommittee (CS), 26 th Airbreathing Propulsion Subcommittee (APS), 20th Propulsion Systems Hazards Subcommittee (PSHS), and 21 Modeling and Simulation Subcommittee. The meeting was held 8-12 April 2002 at the Bayside Inn at The Sandestin Golf & Beach Resort and Eglin Air Force Base, Destin, Florida. Topics cover five major technology areas including: 1) Combustion - Propellant Combustion, Ingredient Kinetics, Metal Combustion, Decomposition Processes and Material Characterization, Rocket Motor Combustion, and Liquid & Hybrid Combustion; 2) Liquid Rocket Engines - Low Cost Hydrocarbon Liquid Rocket Engines, Liquid Propulsion Turbines, Liquid Propulsion Pumps, and Staged Combustion Injector Technology; 3) Modeling & Simulation - Development of Multi- Disciplinary RBCC Modeling, Gun Modeling, and Computational Modeling for Liquid Propellant Combustion; 4) Guns Gun Propelling Charge Design, and ETC Gun Propulsion; and 5) Airbreathing - Scramjet an Ramjet- S&T Program Overviews.
A zero power harmonic transponder sensor for ubiquitous wireless μL liquid-volume monitoring
NASA Astrophysics Data System (ADS)
Huang, Haiyu; Chen, Pai-Yen; Hung, Cheng-Hsien; Gharpurey, Ranjit; Akinwande, Deji
2016-01-01
Autonomous liquid-volume monitoring is crucial in ubiquitous healthcare. However, conventional approach is based on either human visual observation or expensive detectors, which are costly for future pervasive monitoring. Here we introduce a novel approach based on passive harmonic transponder antenna sensor and frequency hopping spread spectrum (FHSS) pattern analysis, to provide a very low cost wireless μL-resolution liquid-volume monitoring without battery or digital circuits. In our conceptual demonstration, the harmonic transponder comprises of a passive nonlinear frequency multiplier connected to a metamaterial-inspired 3-D antenna designed to be highly sensitive to the liquid-volume within a confined region. The transponder first receives some FHSS signal from an interrogator, then converts such signal to its harmonic band and re-radiates through the antenna sensor. The harmonic signal is picked up by a sniffer receiver and decoded through pattern analysis of the high dimensional FHSS signal strength data. A robust, zero power, absolute accuracy wireless liquid-volume monitoring is realized in the presence of strong direct coupling, background scatters, distance variance as well as near-field human-body interference. The concepts of passive harmonic transponder sensor, metamaterial-inspired antenna sensor, and FHSS pattern analysis based sensor decoding may help establishing cost-effective, energy-efficient and intelligent wireless pervasive healthcare monitoring platforms.
A zero power harmonic transponder sensor for ubiquitous wireless μL liquid-volume monitoring.
Huang, Haiyu; Chen, Pai-Yen; Hung, Cheng-Hsien; Gharpurey, Ranjit; Akinwande, Deji
2016-01-06
Autonomous liquid-volume monitoring is crucial in ubiquitous healthcare. However, conventional approach is based on either human visual observation or expensive detectors, which are costly for future pervasive monitoring. Here we introduce a novel approach based on passive harmonic transponder antenna sensor and frequency hopping spread spectrum (FHSS) pattern analysis, to provide a very low cost wireless μL-resolution liquid-volume monitoring without battery or digital circuits. In our conceptual demonstration, the harmonic transponder comprises of a passive nonlinear frequency multiplier connected to a metamaterial-inspired 3-D antenna designed to be highly sensitive to the liquid-volume within a confined region. The transponder first receives some FHSS signal from an interrogator, then converts such signal to its harmonic band and re-radiates through the antenna sensor. The harmonic signal is picked up by a sniffer receiver and decoded through pattern analysis of the high dimensional FHSS signal strength data. A robust, zero power, absolute accuracy wireless liquid-volume monitoring is realized in the presence of strong direct coupling, background scatters, distance variance as well as near-field human-body interference. The concepts of passive harmonic transponder sensor, metamaterial-inspired antenna sensor, and FHSS pattern analysis based sensor decoding may help establishing cost-effective, energy-efficient and intelligent wireless pervasive healthcare monitoring platforms.
A zero power harmonic transponder sensor for ubiquitous wireless μL liquid-volume monitoring
Huang, Haiyu; Chen, Pai-Yen; Hung, Cheng-Hsien; Gharpurey, Ranjit; Akinwande, Deji
2016-01-01
Autonomous liquid-volume monitoring is crucial in ubiquitous healthcare. However, conventional approach is based on either human visual observation or expensive detectors, which are costly for future pervasive monitoring. Here we introduce a novel approach based on passive harmonic transponder antenna sensor and frequency hopping spread spectrum (FHSS) pattern analysis, to provide a very low cost wireless μL-resolution liquid-volume monitoring without battery or digital circuits. In our conceptual demonstration, the harmonic transponder comprises of a passive nonlinear frequency multiplier connected to a metamaterial-inspired 3-D antenna designed to be highly sensitive to the liquid-volume within a confined region. The transponder first receives some FHSS signal from an interrogator, then converts such signal to its harmonic band and re-radiates through the antenna sensor. The harmonic signal is picked up by a sniffer receiver and decoded through pattern analysis of the high dimensional FHSS signal strength data. A robust, zero power, absolute accuracy wireless liquid-volume monitoring is realized in the presence of strong direct coupling, background scatters, distance variance as well as near-field human-body interference. The concepts of passive harmonic transponder sensor, metamaterial-inspired antenna sensor, and FHSS pattern analysis based sensor decoding may help establishing cost-effective, energy-efficient and intelligent wireless pervasive healthcare monitoring platforms. PMID:26732251
A perfluorochemical loss/restoration (L/R) system for tidal liquid ventilation.
Libros, R; Philips, C M; Wolfson, M R; Shaffer, T H
2000-01-01
Tidal liquid ventilation is the transport of dissolved respiratory gases via volume exchange of perfluorochemical (PFC) liquid to and from the PFC-filled lung. All gas-liquid surface tension is eliminated, increasing compliance and providing lung protection due to lower inflation pressures. Tidal liquid ventilation is achieved by cycling fluid from a reservoir to and from the lung by a ventilator. Current approaches are microprocessor-based with feedback control. During inspiration, warmed oxygenated PFC liquid is pumped from a fluid reservoir/gas exchanger into the lung. PFC fluid is conserved by condensing (60-80% efficiency) vapor in the expired gas. A feedback-control system was developed to automatically replace PFC lost due to condenser inefficiency. This loss/restoration (L/R) system consists of a PFC-vapor thermal detector (+/- 2.5%), pneumatics, amplifiers, a gas flow detector (+/- 1%), a PFC pump (+/- 5%), and a controller. Gravimetric studies of perflubron loss from a flask due to evaporation were compared with experimental L/R results and found to be within +/- 1.4%. In addition, when L/R studies were conducted with a previously reported liquid ventilation system over a four-hour period, the L/R system maintained system perflubron volume to within +/- 1% of prime volume and 11.5% of replacement volume, and the difference between experimental PFC loss and that of the L/R system was 1.8 mL/hr. These studies suggest that the PFC L/R system may have significant economic (appropriate dosing for PFC loss) as well as physiologic (maintenance of PFC inventory in the lungs and liquid ventilator) impact on liquid ventilation procedures.
New PDLC materials obtained from dispersion of LC under microgravity
NASA Astrophysics Data System (ADS)
Matos, M. R.; Leitao, J. C.; Andre, R. M.; Zambujal, R.; Carmelo Rosa, Carla; Simeao Carvalho, P.; Podgorski, Thomas
Aknowledgements: This project has been supported by ESA-Education, the University of Porto, IFIMUP and INESC-Porto. Bibliography: [1] F Bloisi and L Vicari. Optical Applications of Liquid Crystals, chapter 4: Polymer-dispersed liquid crystals. Institute of Physics Publishing, 2003. [2] J. William Doane. Liquid Crystals Applications and Uses, volume 1, chapter 14: Polymer Dispersed Liquid Crystal Displays, pages 361-391. World Scientific, 1990. [3] K. Parbhakar, J. M. Jin, H. M. Nguyen, and L. H. Dao. Effect of microgravity on the distribution of liquid-crystal droplets dispersed in a polymer matrix. CHEMISTRY OF MA-TERIALS, 8(??):1210-1216, Jun 1996. [4] Paul S. Drzaic. Liquid Crystal Dispersions, volume 1. World Scientific, 1995.
NASA Technical Reports Server (NTRS)
Hawkins-Reynolds, Ebony; Le, Hung; Stephan, Ryan
2010-01-01
Microchannel technology can be incorporated into heat exchanger designs to decrease the mass and volume of space hardware. The National Aeronautics and Space Administration at the Johnson Space Center (NASA JSC) partnered with Pacific Northwest National Laboratories (PNNL) to develop a liquid/liquid microchannel heat exchanger that has significant mass and volume savings without sacrificing thermal and pressure drop performance. PNNL designed the microchannel heat exchanger to the same performance design requirements of a conventional plate and fin liquid/liquid heat exchanger; 3 kW duty with inlet temperatures of 26 C and 4 C. Both heat exchangers were tested using the same test parameters on a test apparatus and performance data compared.
Miranda-Fuentes, Antonio; Rodríguez-Lizana, Antonio; Gil, Emilio; Agüera-Vega, J; Gil-Ribes, Jesús A
2015-12-15
Olive is a key crop in Europe, especially in countries around the Mediterranean Basin. Optimising the parameters of a spray is essential for sustainable pesticide use, especially in high-input systems, such as the super-intensive hedgerow system. Parameters may be optimised by adjusting the applied volume and airflow rate of sprays, in addition to the liquid to air proportion and the relationship between air velocity and airflow rate. Two spray experiments using a commercial airblast sprayer were conducted in a super-intensive orchard to study how varying the liquid volume rate (testing volumes of 182, 619, and 1603 l ha(-1)) and volumetric airflow rate (with flow rates of 11.93, 8.90, and 6.15 m(3) s(-1)) influences the coverage parameters and the amount and distribution of deposits in different zones of the canopy.. Our results showed that an increase in the application volume raised the mean deposit and percentage coverage, but decreased the application efficiency, spray penetration, and deposit homogeneity. Furthermore, we found that the volumetric airflow rate had a lower influence on the studied parameters than the liquid volume; however, an increase in the airflow rate improved the application efficiency and homogeneity to a certain threshold, after which the spray quality decreased. This decrease was observed in the high-flow treatment. Our results demonstrate that intermediate liquid volume rates and volumetric airflow rates are required for the optimal spraying of pesticides on super-intensive olive crops, and would reduce current pollution levels. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Spaulding, R. S.; Hales, B.; Beck, J. C.; Degrandpre, M. D.
2008-12-01
The four measurable inorganic carbon parameters commonly measured as part of oceanic carbon cycle studies are total dissolved inorganic carbon (DIC), total alkalinity (AT), hydrogen ion concentration (pH) and partial pressure of CO2 (pCO2). AT determination is critical for anthropogenic CO2 inventory calculations and for quantifying CaCO3 saturation. Additionally, measurement of AT in combination with one other carbonate parameter can be used to describe the inorganic carbon equilibria. Current methods for measuring AT require calibrated volumetric flasks and burettes, gravimetry, or precise flow measurements. These methods also require analysis times of ˜15 min and sample volumes of ˜200 mL, and sample introduction is not automated, resulting in labor-intensive measurements and low temporal resolution. The Tracer Monitored Titration (TMT) system was previously developed at the University of Montana for AT measurements. The TMT is not dependent on accurate gravimetric, volumetric or flow rate measurements because it relies on a pH-sensitive indicator (tracer) to track the amount of titrant added to the sample. Sample and a titrant-indicator mixture are mechanically stirred in an optical flow cell and pH is calculated using the indicator equilibrium constant and the spectrophotometrically determined concentrations of the acid and base forms of the indicator. AT is then determined using these data in a non-linear least squares regression of the AT mass and proton balances. The precision and accuracy of the TMT are 2 and 4 micromol per kg in 16 min using 110-mL of sample. The TMT is dependent on complete mixing of titrant with the sample and accurate absorbance measurements. We have developed the segmented-flow TMT (SF- TMT) to improve on these aspects and decrease sample analysis time. The TMT uses segmented flow instead of active mixing and a white LED instead of a tungsten-halogen light source. Air is added to the liquid flow stream, producing segments of liquid separated by air bubbles. Because liquid is not transferred between flow segments, there is rapid flushing which reduces sample volume to <10 mL. Additionally, the slower movement of liquid at the tube walls compared to that at the tube center creates circulation within each liquid segment, mixing the sample and eliminating the need for mechanical stirring. The white LED has higher output at the wavelengths of interest, thus improving the precision of absorbance measurements. These improvements result in a faster, simpler method for measuring AT.
Fan, Chen; Cao, Xueli; Liu, Man; Wang, Wei
2016-03-04
Alternariol (AOH), alternariol monomethyl ether (AME), and tenuazonic acid (TeA) are some of the main Alternaria mycotoxins that can be found as contaminants in food materials. The objective of this study was to develop a pretreatment method with countercurrent chromatography (CCC) for enrichment and cleanup of trace Alternaria mycotoxins in food samples prior to high-performance liquid chromatography (HPLC) analysis. An Analytical CCC instrument with a column volume 22.5mL was used, and a two-phase solvent system composed of ethyl acetate and water modified with 6% [HOOMIM][Cl] in mass to volume ratio was selected. Under the optimized CCC operation conditions, trace amounts of AOH, AME, and TeA in large volume of liquid sample were efficiently extracted and enriched in the stationary phase, and then eluted out just by reversing the stationary phase as mobile phase in the opposite flowing direction tail-to-head. The enrichment and elution strategies are unique and can be fulfilled online with high enrichment factors (87-114) and high recoveries (81.14-110.94%). The method has been successively applied to the determination of Alternaria mycotoxins in real apple juice and wine samples with the limits of detection (LOD) in the range of 0.03-0.14μgL(-1). Totally 12 wine samples and 15 apple juice samples from the local market were analyzed. The detection rate of AOH and AME in both kinds of the samples were more than 50%, while TeA was found in relatively high level of 1.75-49.61μgL(-1) in some of the apple juice samples. The proposed method is simple, rapid, and sensitive and could also be used for the analysis and monitoring of Alternaria mycotoxin in other food samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Esophageal function testing using multichannel intraluminal impedance.
Srinivasan, R; Vela, M F; Katz, P O; Tutuian, R; Castell, J A; Castell, D O
2001-03-01
Multichannel intraluminal impedance (MII) is a new technique for evaluation of bolus transport. We evaluated esophageal function using bolus transport time (BTT) and contraction wave velocity (CWV) of liquid, semisolid, and solid boluses. Ten healthy subjects underwent MII swallow evaluation with various boluses of sterile water (pH 5), applesauce, three different sized marshmallows, and iced and 130 degrees F water. The effect of bethanechol was also studied. There was no difference in BTT or CWV for all water volumes from 1 to 20 ml. There was significant linear increase of BTT with progressively larger volumes of applesauce, and BTT of applesauce was longer than for water. BTT was significantly longer with large marshmallows vs. small and medium and was longer than for water. BTT for iced water was similar to 130 degrees F water. Applesauce showed a significant linear decrease of CWV with progressively larger volumes and was slower than water. Marshmallow showed significantly slower CWV with the large vs. small, and CWV for ice water was significantly slower than 130 degrees F water. Therefore, BTT of liquid is constant, whereas BTT of semisolid and solid are volume dependent and longer than liquids. CWV of semisolids and solids are slower than liquids. CWV of cold liquids is slower than warm liquids. MII can be used as a discriminating test of esophageal function.
Tarran, Robert; Grubb, Barbara R.; Gatzy, John T.; Davis, C. William; Boucher, Richard C.
2001-01-01
Two hypotheses have been proposed recently that offer different views on the role of airway surface liquid (ASL) in lung defense. The “compositional” hypothesis predicts that ASL [NaCl] is kept low (<50 mM) by passive forces to permit antimicrobial factors to act as a chemical defense. The “volume” hypothesis predicts that ASL volume (height) is regulated isotonically by active ion transport to maintain efficient mechanical mucus clearance as the primary form of lung defense. To compare these hypotheses, we searched for roles for: (1) passive forces (surface tension, ciliary tip capillarity, Donnan, and nonionic osmolytes) in the regulation of ASL composition; and (2) active ion transport in ASL volume regulation. In primary human tracheobronchial cultures, we found no evidence that a low [NaCl] ASL could be produced by passive forces, or that nonionic osmolytes contributed substantially to ASL osmolality. Instead, we found that active ion transport regulated ASL volume (height), and that feedback existed between the ASL and airway epithelia to govern the rate of ion transport and volume absorption. The mucus layer acted as a “reservoir” to buffer periciliary liquid layer height (7 μm) at a level optimal for mucus transport by donating or accepting liquid to or from the periciliary liquid layer, respectively. These data favor the active ion transport/volume model hypothesis to describe ASL physiology. PMID:11479349
Zhang, Jiaheng; Gao, Haixiang; Peng, Bing; Li, Yubo; Li, Songqing; Zhou, Zhiqiang
2012-01-15
A novel pretreatment method termed ultrasound-assisted dispersive liquid-liquid microextraction (UADLLME) coupled with high-performance liquid chromatography-ultraviolet detector (HPLC-UV) was applied for the detection of four synthesized metabolites of mequindox in pig urine samples. A total volume of 200 μL of methanol (dispersant) and 60 μL of 1,1,2,2-tetrachloroethane (extract) were injected into 5.0 mL of urine sample and then emulsified by ultrasound treatment for 4 min to form a cloudy solution. The effect of several factors on the recovery of each metabolite was investigated by a fitting derivation method for the first time. Under optimum conditions, the method yields a linear calibration curve in the concentration range from 0.5 to 500 μg/L and a limit of detection (LOD) of 0.16-0.28 μg/L for target analytes. The recoveries ranged from 72.0% to 91.3% with a relative standard deviation (RSD) of less than 5.2%. The enrichment factors for the four compounds ranged from 75 to 95. Two pig urine samples were successfully analyzed using the proposed method. Copyright © 2011 Elsevier B.V. All rights reserved.
Davies, M W; Dunster, K R
2000-08-01
During partial liquid ventilation perfluorocarbon vapour is present in the exhaled gases. The volumes of these gases are measured by pneumotachometers. Error in measuring tidal volumes will give erroneous measurement of lung compliance during partial liquid ventilation. We aim to compare measured tidal volumes with and without perfluorocarbon vapour using tidal volumes suitable for use in neonates. Tidal volumes were produced with a 100 ml calibration syringe from 20 to 100 ml and with a calibrated Harvard rodent ventilator from 2.5 to 20 ml. Control tidal volumes were drawn from a humidifier chamber containing water vapour and the PFC tidal volumes were drawn from a humidifier chamber containing water and perfluorocarbon (FC-77) vapour. Tidal volumes were measured by a fixed orifice, target, differential pressure flowmeter (VenTrak) or a hot-wire anenometer (Bear Cub) placed between the calibration syringe or ventilator and the humidifier chamber. All tidal volumes measured with perfluorocarbon vapour were increased compared with control (ANOVA p < 0.001 and post t-test p < 0.0001). Measured tidal volume increased from 7 to 16% with the fixed orifice type flow-meter, and from 35 to 41% with the hot-wire type. In conclusion, perfluorocarbon vapour flowing through pneumotachometers gives falsely high tidal volume measurements. Calculation of lung compliance must take into account the effect of perfluorocarbon vapour on the measurement of tidal volume.
Total petroleum systems of the Illizi Province, Algeria and Libya; Tanezzuft-Illizi
Klett, T.R.
2000-01-01
Undiscovered conventional oil and gas resources were assessed within a total petroleum system of the Illizi Province (2056) as part of the U.S. Geological Survey World Petroleum Assessment 2000. The Illizi Province is in eastern Algeria and a small portion of western Libya. The province and its total petroleum system coincide with the Illizi Basin. Although several total petroleum systems may exist within the Illizi Province, only one “composite” total petroleum system is identified. This total petroleum system comprises a single assessment unit. The main source rocks are the Silurian Tanezzuft Formation (or lateral equivalents) and Middle to Upper Devonian mudstone. The total petroleum system was named after the oldest major source rock and the basin in which it resides. The estimated means of the undiscovered conventional petroleum volumes in the Tanezzuft-Illizi Total Petroleum System are 2,814 million barrels of oil (MMBO), 27,785 billion cubic feet of gas (BCFG), and 873 million barrels of natural gas liquids (MMBNGL).
NASA Astrophysics Data System (ADS)
Guo, X.; Lange, R. A.; Ai, Y.
2010-12-01
FeO is an important component in magmatic liquids and yet its partial molar volume at one bar is not as well known as that for Fe2O3 because of the difficulty of performing double-bob density measurements under reducing conditions. Moreover, there is growing evidence from spectroscopic studies that Fe2+ occurs in 4, 5, and 6-fold coordination in silicate melts, and it is expected that the partial molar volume and compressibility of the FeO component will vary accordingly. We have conducted both density and relaxed sound speed measurements on four liquids in the An-Di-Hd (CaAl2Si2O8-CaMgSi2O6-CaFeSi2O6) system: (1) Di-Hd (50:50), (2) An-Hd (50:50), (3) An-Di-Hd (33:33:33) and (4) Hd (100). Densities were measured between 1573 and 1838 K at one bar with the double-bob Archimedean method using molybdenum bobs and crucibles in a reducing gas (1%CO-99%Ar) environment. The sound speeds were measured under similar conditions with a frequency-sweep acoustic interferometer, and used to calculate isothermal compressibility. All the density data for the three multi-component (model basalt) liquids were combined with density data on SiO2-Al2O3-CaO-MgO-K2O-Na2O liquids (Lange, 1997) in a fit to a linear volume equation; the results lead to a partial molar volume (±1σ) for FeO =11.7 ± 0.3(±1σ) cm3/mol at 1723 K. This value is similar to that for crystalline FeO at 298 K (halite structure; 12.06 cm3/mol), which suggests an average Fe2+ coordination of ~6 in these model basalt compositions. In contrast, the fitted partial molar volume of FeO in pure hedenbergite liquid is 14.6 ± 0.3 at 1723 K, which is consistent with an average Fe2+ coordination of 4.3 derived from EXAFS spectroscopy (Rossano, 2000). Similarly, all the compressibility data for the three multi-component liquids were combined with compressibility data on SiO2-Al2O3-CaO-MgO liquids (Ai and Lange, 2008) in a fit to an ideal mixing model for melt compressibility; the results lead to a partial molar compressibility (±1σ) for FeO = 2.4 (± 0.3) 10-2 GPa-1 at 1723 K. In contrast, the compressibility of FeO in pure hedenbergite liquid is more than twice as large: 6.3 (± 0.2) 10-2 GPa-1. When these results are combined with density and sound speed data on CaO-FeO-SiO2 liquids at one bar (Guo et al., 2009), a systematic and linear variation between the partial molar volume and compressibility of the FeO component is obtained, which appears to track changes in the average Fe2+ coordination in these liquids. Therefore, the three most important conclusions of this study are: (1) ideal mixing of volume and compressibility does not occur for all FeO-bearing magmatic liquids, owing to changes in Fe2+ coordination, (2) the partial molar volume and compressibility of FeO varies linearly and systematically with Fe2+ coordination, and (3) ideal mixing of volume and compressibility does occur among the three mixed An-Di-Hd liquids, presumably because of a common, average Fe2+ coordination of ~6.
NASA Astrophysics Data System (ADS)
Bakker, Ronald J.
2018-06-01
The program AqSo_NaCl has been developed to calculate pressure - molar volume - temperature - composition (p-V-T-x) properties, enthalpy, and heat capacity of the binary H2O-NaCl system. The algorithms are designed in BASIC within the Xojo programming environment, and can be operated as stand-alone project with Macintosh-, Windows-, and Unix-based operating systems. A series of ten self-instructive interfaces (modules) are developed to calculate fluid inclusion properties and pore fluid properties. The modules may be used to calculate properties of pure NaCl, the halite-liquidus, the halite-vapourus, dew-point and bubble-point curves (liquid-vapour), critical point, and SLV solid-liquid-vapour curves at temperatures above 0.1 °C (with halite) and below 0.1 °C (with ice or hydrohalite). Isochores of homogeneous fluids and unmixed fluids in a closed system can be calculated and exported to a.txt file. Isochores calculated for fluid inclusions can be corrected according to the volumetric properties of quartz. Microthermometric data, i.e. dissolution temperatures and homogenization temperatures, can be used to calculated bulk fluid properties of fluid inclusions. Alternatively, in the absence of total homogenization temperature the volume fraction of the liquid phase in fluid inclusions can be used to obtain bulk properties.
Measurement of the airway surface liquid volume with simple light refraction microscopy.
Harvey, Peter R; Tarran, Robert; Garoff, Stephen; Myerburg, Mike M
2011-09-01
In the cystic fibrosis (CF) lung, the airway surface liquid (ASL) volume is depleted, impairing mucus clearance from the lung and leading to chronic airway infection and obstruction. Several therapeutics have been developed that aim to restore normal airway surface hydration to the CF airway, yet preclinical evaluation of these agents is hindered by the paucity of methods available to directly measure the ASL. Therefore, we sought to develop a straightforward approach to measure the ASL volume that would serve as the basis for a standardized method to assess mucosal hydration using readily available resources. Primary human bronchial epithelial (HBE) cells cultured at an air-liquid interface develop a liquid meniscus at the edge of the culture. We hypothesized that the size of the fluid meniscus is determined by the ASL volume, and could be measured as an index of the epithelial surface hydration status. A simple method was developed to measure the volume of fluid present in meniscus by imaging the refraction of light at the ASL interface with the culture wall using low-magnification microscopy. Using this method, we found that primary CF HBE cells had a reduced ASL volume compared with non-CF HBE cells, and that known modulators of ASL volume caused the predicted responses. Thus, we have demonstrated that this method can detect physiologically relevant changes in the ASL volume, and propose that this novel approach may be used to rapidly assess the effects of airway hydration therapies in high-throughput screening assays.
Titan's missing ethane: From the atmosphere to the subsurface
NASA Astrophysics Data System (ADS)
Gilliam, Ashley E.; Lerman, Abraham
2016-09-01
The second most abundant component of the present-day Titan atmosphere, methane (CH4), is known to undergo photolytic conversion to ethane (C2H6) that accumulates as a liquid on Titan's surface. Condensation temperature of ethane is higher than that of methane, so that ethane "rain" may be expected to occur before the liquefaction of methane. At present, the partial pressure of ethane in the atmosphere is 1E-5 bar, much lower than 1E-1 bar of CH4. Estimated 8.46E17 kg or 1.37E6 km3 of C2H6 have been produced on Titan since accretion. The Titan surface reservoirs of ethane are lakes and craters, of estimated volume of 50,000 km3 and 61,000 km3, respectively. As these are smaller than the total volume of liquid ethane produced in the course of Titan's history, the excess may be stored in the subsurface of the crust, made primarily of water ice. The minimum porosity of the crust needed to accommodate all the liquid ethane would be only 0.9% of the uppermost 2 km of the crust. The occurrence of CH4 and liquid C2H6 on Titan has led to much speculation on the possibility of life on that satellite. The aggregation of organic molecules in a "primordial soup or bullion" depends in part on the viscosity of the medium, diffusivity of organic molecules in it, and rates of polymerization reactions. The temperatures on Titan, much lower than on primordial Earth, are less favorable to the "Second Coming of life" on Titan.
The seasonal performance of a liquid-desiccant air conditioner
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lowenstein, A.; Novosel, D.
1995-08-01
Prior reports on liquid-desiccant systems have focused on their steady-state operation at ARI design conditions. By studying their performance during an entire cooling season, the computer modeling presented here shows that liquid-desiccant systems can have a very high seasonal coefficient of performance (COP). For a liquid-desiccant system that uses a double-effect boiler, COPs ranging from 1.44 in a humid location (Houston) to 2.24 in a dry location (Phoenix) are achieved by fully exploiting indirect evaporative cooling and providing only the minimum latent cooling needed to meet the loads on the building. This minimizes the amount of water absorbed by themore » desiccant and, hence, the amount of thermal energy needed to regenerate it. In applications where latent loads are very high, such as processing the high volumes of ventilation air required to maintain good indoor air quality, the liquid-desiccant air conditioner again has an advantage over vapor-compression equipment. In this study, a liquid-desiccant system is modeled that cools and dehumidifies only the ventilation air of an office building in Atlanta. Although processing an airstream that is only 25% of the total air delivered to the building, the liquid-desiccant system is able to meet 52% of the building`s seasonal cooling requirements and reduce the building`s peak electrical demand by about 47%.« less
A smartphone controlled handheld microfluidic liquid handling system.
Li, Baichen; Li, Lin; Guan, Allan; Dong, Quan; Ruan, Kangcheng; Hu, Ronggui; Li, Zhenyu
2014-10-21
Microfluidics and lab-on-a-chip technologies have made it possible to manipulate small volume liquids with unprecedented resolution, automation and integration. However, most current microfluidic systems still rely on bulky off-chip infrastructures such as compressed pressure sources, syringe pumps and computers to achieve complex liquid manipulation functions. Here, we present a handheld automated microfluidic liquid handling system controlled by a smartphone, which is enabled by combining elastomeric on-chip valves and a compact pneumatic system. As a demonstration, we show that the system can automatically perform all the liquid handling steps of a bead-based HIV1 p24 sandwich immunoassay on a multi-layer PDMS chip without any human intervention. The footprint of the system is 6 × 10.5 × 16.5 cm, and the total weight is 829 g including battery. Powered by a 12.8 V 1500 mAh Li battery, the system consumed 2.2 W on average during the immunoassay and lasted for 8.7 h. This handheld microfluidic liquid handling platform is generally applicable to many biochemical and cell-based assays requiring complex liquid manipulation and sample preparation steps such as FISH, PCR, flow cytometry and nucleic acid sequencing. In particular, the integration of this technology with read-out biosensors may help enable the realization of the long-sought Tricorder-like handheld in vitro diagnostic (IVD) systems.
Lipin, B.R.
1993-01-01
This paper explores the hypothesis that chromate seams in the Stillwater Complex formed in response to periodic increases in total pressure in the chamber. Total pressure increased because of the positive ??V of nucleation of CO2 bubbles in the melt and their subsequent rise through the magma chamber, during which the bubbles increased in volume by a factor of 4-6. By analogy with the pressure changes in the summit chambers of Kilauea and Krafla volcanoes, the maximum variation was 0.2-0.25 kbar, or 5-10% of the total pressure in the Stillwater chamber. An evaluation of the likelihood of fountaining and mixing of a new, primitive liquid that entered the chamber with the somewhat more evolved liquid already in the chamber is based upon calculations using observed and inferred velocities and flow rates of basaltic magmas moving through volcanic fissures. The calculations indicate that hot, dense magma would have oozed, rather than fountained into the chamber, and early mixing of the new and residual magmas that could have resulted in chromite crystallizing alone did not take place. -from Author
Dose monitoring in Partial Liquid Ventilation by infrared measurement of expired perfluorochemicals.
Mazzoni, M; Nugent, L; Klein, D; Hoffman, J; Sekins, K M; Flaim, S F
1999-01-01
Patients undergoing Partial Liquid Ventilation (PLV) with the perfluorochemical liquid perflubron (PFB) continuously evaporate the drug from the lung during ventilatory expiration. In this study, two infrared (IR) devices, a modified industrial analyzer ("experimental prototype") and a custom-designed device suitable for use in a clinical environment ("clinical prototype"), were calibrated and validated on the bench to measure a range of PFB concentrations (CPFB) in a gas stream. PFB loss from the lung (area under the CPFB-vs-time-curve) could be correlated during PLV simulation with changes in tidal volume, breathing rate, and variable CPFB-vs-time profiles. The two IR devices produced nearly identical measurements for the same CPFB standards (maximum deviation = 1.5%). The experimental IR prototype was tested in 17 anesthetized, paralyzed, and ventilated swine (42-53 kg) to quantify the total amount and rate of evaporate loss of PFB over 12 hours of PLV, both with and without periodic supplemental PFB doses. The residual PFB volumes in the animal lungs at the end of the study, as determined by a gravimetric postmortem lung method, were found to agree on average for all animals to within 10% of the residual PFB volume as predicted by the IR approach. Furthermore, the IR signal of CPFB does not appear to correlate with the absolute amount of PFB in the lungs, but may reflect the relative proportion of PFB-wetted airway and alveolar surface. The authors conclude that IR quantitation of PFB evaporative loss is acceptably accurate for extended periods of PLV and may be a useful tool in the clinic for PFB dose monitoring and maintenance, thereby helping to optimize PLV treatment.
Fractionalized Fermi liquid in a Kondo-Heisenberg model
Tsvelik, A. M.
2016-10-10
The Kondo-Heisenberg model is used as a controllable tool to demonstrate the existence of a peculiar metallic state with unbroken translational symmetry where the Fermi surface volume is not controlled by the total electron density. Here, I use a nonperturbative approach where the strongest interactions are taken into account by means of exact solution, and corrections are controllable. The resulting metallic state represents a fractionalized Fermi liquid where well defined quasiparticles coexist with gapped fractionalized collective excitations, in agreement with the general requirements formulated by T. Senthil et al. [Phys. Rev. Lett. 90, 216403 (2003)]. Furthermore, the system undergoes amore » phase transition to an ordered phase (charge density wave or superconducting), at the transition temperature which is parametrically small in comparison to the quasiparticle Fermi energy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oanh, N.T.K.; Reutergardh, L.B.; Dung, N.T.
Total suspended particulate matter in ambient air was sampled by high volume samplers at four sites at the Asian Institute of Technology campus, west of the Phahonyothin Road, Phathumthani Province, 40 km North of Bangkok, Thailand. The concentrations of 18 polycyclic aromatic hydrocarbons (PAHs), were measured by gas liquid chromatography with flame ionization and/or liquid solid chromatography with fluorescence detection. The PAH profile with relatively high concentrations of benzo(ghi)perylene and coronene, decreasing with the distance from the road, suggested a substantial contribution from the traffic. The concentrations in the core of the campus were compatible to those reported for residentialmore » areas in Bangkok, but higher than some western metropolitan areas.« less
Cumulative Ocean Volume Estimates of the Solar System
NASA Astrophysics Data System (ADS)
Frank, E. A.; Mojzsis, S. J.
2010-12-01
Although there has been much consideration for habitability in silicate planets and icy bodies, this information has never been quantitatively gathered into a single approximation encompassing our solar system from star to cometary halo. Here we present an estimate for the total habitable volume of the solar system by constraining our definition of habitable environments to those to which terrestrial microbial extremophiles could theoretically be transplanted and yet survive. The documented terrestrial extremophile inventory stretches environmental constraints for habitable temperature and pH space of T ~ -15oC to 121oC and pH ~ 0 to 13.5, salinities >35% NaCl, and gamma radiation doses of 10,000 to 11,000 grays [1]. Pressure is likely not a limiting factor to life [2]. We applied these criteria in our analysis of the geophysical habitable potential of the icy satellites and small icy bodies. Given the broad spectrum of environmental tolerance, we are optimistic that our pessimistic estimates are conservative. Beyond the reaches of our inner solar system's conventional habitable zone (Earth, Mars and perhaps Venus) is Ceres, a dwarf planet in the habitable zone that could possess a significant liquid water ocean if that water contains anti-freezing species [3]. Yet further out, Europa is a small icy satellite that has generated much excitement for astrobiological potential due to its putative subsurface liquid water ocean. It is widely promulgated that the icy moons Enceladus, Triton, Callisto, Ganymede, and Titan likewise have also sustained liquid water oceans. If oceans in Europa, Enceladus, and Triton have direct contact with a rocky mantle hot enough to melt, hydrothermal vents could provide an energy source for chemotrophic organisms. Although oceans in the remaining icy satellites may be wedged between two layers of ice, their potential for life cannot be precluded. Relative to the Jovian style of icy satellites, trans-neptunian objects (TNOs) - icy bodies located beyond the orbit of Neptune - have received little consideration for their potential as abodes for life. Aided by radiogenic heating, the largest TNOs could still support subsurface liquid water oceans [4]. Calculations of the size and frequency of the largest (>500 km diameter) TNOs as well as the likely thermal histories of these objects suggest that the total volume of liquid water in these bodies may be greater than that of the rest of the solar system combined. [1] Baross et al. (2007) The Limits of Organic Life in Planetary Systems, National Academies Press, Washington, D.C. [2] Sharma et al. (2002) Nature 295, 1514-1516. [3] Castillo-Rogez, J.C. and T.B. McCord (2010) Icarus 205, 443-459. [4] Hussmann et al.(2006) Icarus 195. 258-273.
Potential low cost, safe, high efficiency propellant for future space program
NASA Astrophysics Data System (ADS)
Zhou, D.
2005-03-01
Mixtures of nanometer or micrometer sized carbon powder suspended in hydrogen and methane/hydrogen mixtures are proposed as candidates for low cost, high efficiency propellants for future space programs. While liquid hydrogen has low weight and high heat of combustion per unit mass, because of the low mass density the heat of combustion per unit volume is low, and the liquid hydrogen storage container must be large. The proposed propellants can produce higher gross heat combustion with small volume with trade off of some weight increase. Liquid hydrogen can serve as the fluid component of the propellant in the mixtures and thus used by current rocket engine designs. For example, for the same volume a mixture of 5% methane and 95% hydrogen, can lead to an increase in the gross heat of combustion by about 10% and an increase in the Isp (specific impulse) by 21% compared to a pure liquid hydrogen propellant. At liquid hydrogen temperatures of 20.3 K, methane will be in solid state, and must be formed as fine granules (or slush) to satisfy the requirement of liquid propellant engines.
NASA Astrophysics Data System (ADS)
Shin, Soon-Gi
2000-06-01
The grain growth behaviors of TiC and WC particles in TiC-Ni, TiC-Mo2C-Ni, WC-Co and WC-VC-Co alloys during liquid phase sintering were investigated for different Ni or Co contents and compared with the results of Monte Carlo simulations. In the experimental study, TiC-Ni and WC-Co alloys had a maximum grain size at a certain liquid volume fraction, while the grain size in TiC-Mo2C-Ni and WC-VC-Co alloys increased monotonically with an increasing liquid volume fraction. These results mean that the grain growth of these alloys cannot be explained by the conventional mechanisms for Ostwald ripening, namely diffusion or reaction controlled processes. Monte Carlo simulations with different energy relationships between solidliquid interfaces predicted the effect of the liquid volume fraction on grain size similar to the experimental results. The contiguous boundaries between solid (carbide) particles appear to influence the grain growth behavior in TiC- and WC-based alloys during liquid phase sintering.
Confinement of surface waves at the air-water interface to control aerosol size and dispersity
NASA Astrophysics Data System (ADS)
Nazarzadeh, Elijah; Wilson, Rab; King, Xi; Reboud, Julien; Tassieri, Manlio; Cooper, Jonathan M.
2017-11-01
The precise control over the size and dispersity of droplets, produced within aerosols, is of great interest across many manufacturing, food, cosmetic, and medical industries. Amongst these applications, the delivery of new classes of high value drugs to the lungs has recently attracted significant attention from pharmaceutical companies. This is commonly achieved through the mechanical excitation of surface waves at the air liquid interface of a parent liquid volume. Previous studies have established a correlation between the wavelength on the surface of liquid and the final aerosol size. In this work, we show that the droplet size distribution of aerosols can be controlled by constraining the liquid inside micron-sized cavities and coupling surface acoustic waves into different volumes of liquid inside micro-grids. In particular, we show that by reducing the characteristic physical confinement size (i.e., either the initial liquid volume or the cavities' diameters), higher harmonics of capillary waves are revealed with a consequent reduction of both aerosol mean size and dispersity. In doing so, we provide a new method for the generation and fine control of aerosols' sizes distribution.
Wu, Cyuan-Jhang; Singh, Vickramjeet; Sheng, Yu-Jane; Tsao, Heng-Kwong
2017-08-01
Solute separation of aqueous mixtures is mainly dominated by water vaporization. The evaporation rate of an aqueous drop grows with increasing the liquid-gas interfacial area. The spontaneous spreading behavior of a water droplet on a total wetting surface provides huge liquid-gas interfacial area per unit volume; however, it is halted by the self-pinning phenomenon upon addition of nonvolatile solutes. In this work, it is shown that the solute-induced self-pinning can be overcome by gravity, leading to anisotropic spreading much faster than isotropic spreading. The evaporation rate of anisotropic spreading on a zwitterionic sulfobetaine surface is 25 times larger as that on a poly(methyl methacrylate) surface. Dramatic enhancement of evaporation is demonstrated by simultaneous formation of fog atop liquid film. During anisotropic spreading, the solutes are quickly precipitated out within 30 s, showing the rapid solute-water separation. After repeated spreading process for the dye-containing solution, the mean concentration of the collection is doubled, revealing the concentration efficiency as high as 100%. Gravity-enhanced spreading on total wetting surfaces at room temperature is easy to scale-up with less energy consumption, and thus it has great potentials for the applications of solute separation and concentration.
Direct numerical simulation of droplet-laden isotropic turbulence
NASA Astrophysics Data System (ADS)
Dodd, Michael S.
Interaction of liquid droplets with turbulence is important in numerous applications ranging from rain formation to oil spills to spray combustion. The physical mechanisms of droplet-turbulence interaction are largely unknown, especially when compared to that of solid particles. Compared to solid particles, droplets can deform, break up, coalesce and have internal fluid circulation. The main goal of this work is to investigate using direct numerical simulation (DNS) the physical mechanisms of droplet-turbulence interaction, both for non-evaporating and evaporating droplets. To achieve this objective, we develop and couple a new pressure-correction method with the volume-of-fluid (VoF) method for simulating incompressible two-fluid flows. The method's main advantage is that the variable coefficient Poisson equation that arises in solving the incompressible Navier-Stokes equations for two-fluid flows is reduced to a constant coefficient equation. This equation can then be solved directly using, e.g., the FFT-based parallel Poisson solver. For a 10243 mesh, our new pressure-correction method using a fast Poisson solver is ten to forty times faster than the standard pressure-correction method using multigrid. Using the coupled pressure-correction and VoF method, we perform direct numerical simulations (DNS) of 3130 finite-size, non-evaporating droplets of diameter approximately equal to the Taylor lengthscale and with 5% droplet volume fraction in decaying isotropic turbulence at initial Taylor-scale Reynolds number Relambda = 83. In the droplet-laden cases, we vary one of the following three parameters: the droplet Weber number based on the r.m.s. velocity of turbulence (0.1 ≤ Werms ≤ 5), the droplet- to carrier-fluid density ratio (1 ≤ rhod/rho c ≤ 100) or the droplet- to carrier-fluid viscosity ratio (1 ≤ mud/muc ≤ 100). We derive the turbulence kinetic energy (TKE) equations for the two-fluid, carrier-fluid and droplet-fluid flow. These equations allow us to explain the pathways for TKE exchange between the carrier turbulent flow and the flow inside the droplet. We also explain the role of the interfacial surface energy in the two-fluid TKE equation through work performed by surface tension. Furthermore, we derive the relationship between the power of surface tension and the rate of change of total droplet surface area. This link allows us to explain how droplet deformation, breakup and coalescence play roles in the temporal evolution of TKE. We then extend the code for non-evaporating droplets and develop a combined VoF method and low-Mach-number approach to simulate evaporating and condensing droplets. The two main novelties of the method are: (i) the VOF algorithm captures the motion of the liquid gas interface in the presence of mass transfer due to evaporation and condensation without requiring a projection step for the liquid velocity, and (ii) the low-Mach-number approach allows for local volume changes caused by phase change while the total volume of the liquid-gas system is constant. The method is verified against an analytical solution for a Stefan flow problem, and the D2 law is verified for a single droplet in quiescent gas. Finally, we perform DNS of an evaporating liquid droplet in forced isotropic turbulence. We show that the method accurately captures the temperature and vapor fields in the turbulent regime, and that the local evaporation rate can vary along the droplet surface depending on the structure of the surrounding vapor cloud. We also report the time evolution of the mean Sherwood number, which indicates that turbulence enhances the vaporization rate of liquid droplets.
Brooks, Nicholas J.; Castiglione, Franca; Doherty, Cara M.; Dolan, Andrew; Hill, Anita J.; Hunt, Patricia A.; Matthews, Richard P.; Mauri, Michele; Mele, Andrea; Simonutti, Roberto; Villar-Garcia, Ignacio J.; Weber, Cameron C.
2017-01-01
The formation of ionic liquid (IL) mixtures has been proposed as an approach to rationally fine-tune the physicochemical properties of ILs for a variety of applications. However, the effects of forming such mixtures on the resultant properties of the liquids are only beginning to be understood. Towards a more complete understanding of both the thermodynamics of mixing ILs and the effect of mixing these liquids on their structures and physicochemical properties, the spatial arrangement and free volume of IL mixtures containing the common [C4C1im]+ cation and different anions have been systematically explored using small angle X-ray scattering (SAXS), positron annihilation lifetime spectroscopy (PALS) and 129Xe NMR techniques. Anion size has the greatest effect on the spatial arrangement of the ILs and their mixtures in terms of the size of the non-polar domains and inter-ion distances. It was found that differences in coulombic attraction between oppositely charged ions arising from the distribution of charge density amongst the atoms of the anion also significantly influences these inter-ion distances. PALS and 129Xe NMR results pertaining to the free volume of these mixtures were found to strongly correlate with each other despite the vastly different timescales of these techniques. Furthermore, the excess free volumes calculated from each of these measurements were in excellent agreement with the excess volumes of mixing measured for the IL mixtures investigated. The correspondence of these techniques indicates that the static and dynamic free volume of these liquid mixtures are strongly linked. Consequently, fluxional processes such as hydrogen bonding do not significantly contribute to the free volumes of these liquids compared to the spatial arrangement of ions arising from their size, shape and coulombic attraction. Given the relationship between free volume and transport properties such as viscosity and conductivity, these results provide a link between the structures of IL mixtures, the thermodynamics of mixing and their physicochemical properties. PMID:29619199
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, D.A.; Peloquin, R.A.
Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1982. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 51 sites. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each site is a histogram showing the fraction of the total population within 2 to 80 km around each sitemore » receiving various average dose commitments from the airborne pathways. The total dose commitments from both liquid and airborne pathways ranged from a high of 30 person-rem to a low of 0.007 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 3 person-rem. The total population dose for all sites was estimated at 130 person-rem for the 100 million people considered at risk. The average individual dose commitment from all pathways on a site basis ranged from a low of 6 x 10/sup -7/ mrem to a high of 0.06 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites.« less
Pressure Dependence of Komatiite Liquid Viscosity and Implications for Magma Ocean Rheology
NASA Astrophysics Data System (ADS)
O'Dwyer Brown, L.; Lesher, C. E.; Terasaki, H. G.; Yamada, A.; Sakamaki, T.; Shibazaki, Y.; Ohtani, E.
2009-12-01
The viscosities of komatiite liquids at high pressures and temperatures were investigated using the in-situ falling sphere technique at BL04B1, SPring-8. Komatiites are naturally occurring magmas, rich in network modifying cations. Despite the refractory and fluid nature of komatiite, we successfully measured the viscosity of molten komatiites from Gorgona Island, Colombia (MgO = 17.8 wt.%; NBO/T = 1.5) between 11 and 13 GPa at 2000 C, and from Belingwe, Zimbabwe (MgO = 28.14 wt.%; NBO/T = 2.1) from 12 to 14 GPa at 2000 C. Under isothermal conditions, the viscosity of Gorgona Island komatiite melt increased with pressure, consistent with our previous measurements at lower pressures for this composition. We interpreted this positive pressure dependence as the result of reductions in interatomic space diminishing the free volume of the liquid when compressed. The viscosity of molten komatiite from Belingwe also increased up to 12 GPa, however between 12 and 14 GPa the viscosity is nearly constant. In previous studies of depolymerized silicate liquids, the pressure dependence of viscosity has been shown to reverse from positive to negative between 8 and 10 GPa with corresponding changes in activation volume [1] [2]. In contrast, the activation volume for Belingwe liquid decreases to near zero, but does not become negative above 11 GPa. Similarly, the activation volume for Gorgona Island komatiite remains positive throughout the pressure range investigated. Molecular dynamics simulations of simple MgO-SiO2 liquids with NBO/T > 2 also show a positive pressure dependence, reflecting the dominant control of free-volume reduction on the viscosity of depolymerized melts. However, the more rapid reduction in activation volume with pressure in komatiite liquids may be related to the presence of Al, Ti and other cations that interact and undergo coordination changes unavailable in simple silicate liquids. Along Hadean and post-Hadean mantle adiabats the net effect of temperature and pressure on ultramafic liquids suggests that changes in viscosity are likely modest and viscosity will decrease with depth. Stiffening and isolation of the lower regions of a magma ocean due to increasing melt viscosity seem unlikely. [1] PEPI (2003) 139, 45 [2] EPSL (2005) 240, 589
Liu, Yang; Lu, Caiyan; Twigg, Stephen; Ghaffari, Mehdi; Lin, Junhong; Winograd, Nicholas; Zhang, Q. M.
2013-01-01
The recent boom of energy storage and conversion devices, exploiting ionic liquids (ILs) to enhance the performance, requires an in-depth understanding of this new class of electrolytes in device operation conditions. One central question critical to device performance is how the mobile ions accumulate near charged electrodes. Here, we present the excess ion depth profiles of ILs in ionomer membrane actuators (Aquivion/1-butyl-2,3-dimethylimidazolium chloride (BMMI-Cl), 27 μm thick), characterized directly by Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) at liquid nitrogen temperature. Experimental results reveal that for the IL studied, cations and anions are accumulated at both electrodes. The large difference in the total volume occupied by the excess ions between the two electrodes cause the observed large bending actuation of the actuator. Hence we demonstrate that ToF-SIMS experiment provides great insights on the physics nature of ionic devices. PMID:23512124
Preliminary analysis of the bio-mechanical characteristics for High-kitchen Municipal Solid Waste
NASA Astrophysics Data System (ADS)
Li, He; Zhang, Jian Guo; Lan, Ji Wu; He, Haijie
2017-11-01
Degradation of Municipal Solid Wastes (MSW) results in a change in solid skeleton, particle size and pore structure, inducing an alteration of compressibility and liquid/gas conductivity of the wastes. To investigate the complicated biological, hydraulic and mechanical coupled processes of the MSWs, a pilot-scale experimental device which is consist of waste column container, environment regulation system, vertical loading system and measuring system for liquid/gas conductivity is built. With the experimental systems, long-term tests were set up to investigate the biological, hydraulic and mechanical behaviour of the High-kitchen Municipal solid waste with high organic content and high water content. Different values of vertical stress and different degradation conditions (micro-aerobic and anaerobic) were simulated. Throughout the experiments, the changes in total volume, degree of saturation, leachate quantity and chemistry, LFG generation and composition, liquid and gas conductivity were measured. The experimental results will provide solid data for a development of the Bio-Hydro-Mechanical coupled characteristics for High-kitchen Municipal solid waste.
Hwang, Seung Hwan; Kwon, Shin Hwa; Wang, Zhiqiang; Kim, Tae Hyun; Kang, Young-Hee; Lee, Jae-Yong; Lim, Soon Sung
2016-08-26
Protein tyrosine phosphatase expressed in insulin-sensitive tissues (such as liver, muscle, and adipose tissue) has a key role in the regulation of insulin signaling and pathway activation, making protein tyrosine phosphatase a promising target for the treatment of type 2 diabetes mellitus and obesity and response surface methodology (RSM) is an effective statistical technique for optimizing complex processes using a multi-variant approach. In this study, Zea mays L. (Purple corn kernel, PCK) and its constituents were investigated for protein tyrosine phosphatase 1β (PTP1β) inhibitory activity including enzyme kinetic study and to improve total yields of anthocyanins and polyphenols, four extraction parameters, including temperature, time, solid-liquid ratio, and solvent volume, were optimized by RSM. Isolation of seven polyphenols and five anthocyanins was achieved by PTP1β assay. Among them, cyanidin-3-(6"malonylglucoside) and 3'-methoxyhirsutrin showed the highest PTP1β inhibition with IC50 values of 54.06 and 64.04 μM, respectively and 4.52 mg gallic acid equivalent/g (GAE/g) of total polyphenol content (TPC) and 43.02 mg cyanidin-3-glucoside equivalent/100 g (C3GE/100g) of total anthocyanin content (TAC) were extracted at 40 °C for 8 h with a 33 % solid-liquid ratio and a 1:15 solvent volume. Yields were similar to predictions of 4.58 mg GAE/g of TPC and 42.28 mg C3GE/100 g of TAC. These results indicated that PCK and 3'-methoxyhirsutrin and cyanidin-3-(6"malonylglucoside) might be active natural compounds and could be apply by optimizing of extraction process using response surface methodology.
Mechanical tuning of the evaporation rate of liquid on crossed fibers.
Boulogne, François; Sauret, Alban; Soh, Beatrice; Dressaire, Emilie; Stone, Howard A
2015-03-17
We investigate experimentally the drying of a small volume of perfectly wetting liquid on two crossed fibers. We characterize the drying dynamics for the three liquid morphologies that are encountered in this geometry: drop, column, and a mixed morphology, in which a drop and a column coexist. For each morphology, we rationalize our findings with theoretical models that capture the drying kinetics. We find that the evaporation rate significantly depends upon the liquid morphology and that the drying of the liquid column is faster than the evaporation of the drop and the mixed morphology for a given liquid volume. Finally, we illustrate that shearing a network of fibers reduces the angle between them, changes the morphology toward the column state, and therefore, enhances the drying rate of a volatile liquid deposited on it.
COMPARISON OF TWO DIFFERENT SOLID PHASE EXTRACTION/LARGE VOLUME INJECTION PROCEDURES FOR METHOD 8270
Two solid phase (SPE) and one traditional continuous liquid-liquid extraction method are compared for analysis of Method 8270 SVOCs. Productivity parameters include data quality, sample volume, analysis time and solvent waste.
One SPE system, unique in the U.S., uses aut...
30 CFR 36.26 - Composition of exhaust gas.
Code of Federal Regulations, 2010 CFR
2010-07-01
... immediately at full load and speed. The preliminary liquid-fuel-injection rate shall be such that the exhaust... adverse conditions disclosed by preliminary tests. (b) Final engine adjustment. The liquid fuel supply to... percent, by volume, of carbon monoxide or 0.20 percent, by volume, of oxides of nitrogen (calculated as...
Hydrocarbon Gas Liquids (HGL): Recent Market Trends and Issues
2014-01-01
Over the past five years, rapid growth in U.S. onshore natural gas and oil production has led to increased volumes of natural gas plant liquids (NGPL) and liquefied refinery gases (LRG). The increasing economic importance of these volumes, as a result of their significant growth in production, has revealed the need for better data accuracy and transparency to improve the quality of historical data and projections for supply, demand, and prices of these liquids, co-products, and competing products. To reduce confusion in terminology and improve its presentation of data, EIA has worked with industry and federal and state governments to clarify gas liquid terminology and has developed the term Hydrocarbon Gas Liquids, or HGL.
te Pas, Arjan B.; Kitchen, Marcus J.; Lee, Katie; Wallace, Megan J.; Fouras, Andreas; Lewis, Robert A.; Yagi, Naoto; Uesugi, Kentaro; Hooper, Stuart B.
2016-01-01
Background: A sustained inflation (SI) facilitates lung aeration, but the most effective pressure and duration are unknown. We investigated the effect of gestational age (GA) and airway liquid volume on the required inflation pressure and SI duration. Methods: Rabbit kittens were delivered at 27, 29, and 30 d gestation, intubated and airway liquid was aspirated. Either no liquid (control) or 30 ml/kg of liquid was returned to the airways. Lung gas volumes were measured by plethysmography and phase-contrast X-ray-imaging. Starting at 22 cmH2O, airway pressure was increased until airflow commenced and pressure was then held constant. The SI was truncated when 20 ml/kg air had entered the lung and ventilation continued with intermittent positive pressure ventilation (iPPV). Results: Higher SI pressures and longer durations were required in 27-d kittens compared to 30-d kittens. During iPPV, 27-d kittens needed higher pressures and had lower functional residual capacity (FRC) compared to 30-d kittens. Adding lung liquid increased SI duration, reduced FRC, and increased resistance and pressures during iPPV in 29- and 30-d kittens. Conclusion: Immature kittens required higher starting pressures and longer SI durations to achieve a set inflation volume. Larger airway liquid volumes adversely affected lung function during iPPV in older but not young kittens. PMID:26991259
The therapeutic effect of OK-432 (picibanil) sclerotherapy for benign neck cysts.
Kim, Myung Gu; Kim, Sun Gon; Lee, Jun Ho; Eun, Young Gyu; Yeo, Seung Geun
2008-12-01
In general, benign neck cysts are treated by surgical excision. This can present technical difficulties and frequent recurrences, because of insufficient surgery. Sclerosing agents such as OK-432 have been tested for the nonsurgical treatment of these cysts. We have assessed the efficacy of OK-432 sclerotherapy for benign neck cysts. The study group consisted of 75 patients (42 men, 33 women) diagnosed with and treated for benign neck cysts between March 2001 and December 2007 by intralesional injection of OK-432. The liquid content of each cyst was aspirated as much as possible, and the same volume of OK-432 solution was injected. Patients were assessed by ultrasonography or computerized tomography, and therapeutic outcomes and adverse effects were evaluated by patient age, sex, cyst type, and number of injections. Of the 75 treated patients, 31 (41.3%) showed total shrinkage, seven (9.3%) showed near-total shrinkage (>90% of cyst volume), five (6.6%) showed marked shrinkage (>70% of cyst volume), and 17 (22.7%) showed partial shrinkage (<70% of cyst volume). No response was seen in 15 patients (20%). Despite repeated sclerotherapy, eight patients (10.7%) showed recurrences. Minor adverse effects of therapy included fever, localized pain, and odynophagia but these complications spontaneously disappeared within several days. OK-432 sclerotherapy is a safe and effective primary alternative to surgery in patients with benign neck cysts.
NASA Astrophysics Data System (ADS)
Jeon, S.; Kang, D.-H.; Lee, Y. H.; Lee, S.; Lee, G. W.
2016-11-01
We investigate the relationship between the excess volume and undercoolability of Zr-Ti and Zr-Hf alloy liquids by using electrostatic levitation. Unlike in the case of Zr-Hf alloy liquids in which sizes of the constituent atoms are matched, a remarkable increase of undercoolability and negative excess volumes are observed in Zr-Ti alloy liquids as a function of their compositional ratios. In this work, size mismatch entropies for the liquids were obtained by calculating their hard sphere diameters, number densities, and packing fractions. We also show that the size mismatch entropy, which arises from the differences in atomic sizes of the constituent elements, plays an important role in determining the stabilities of metallic liquids.
Apparatus for Sampling Surface Contamination
NASA Technical Reports Server (NTRS)
Wells, Mark
2008-01-01
An apparatus denoted a swab device has been developed as a convenient means of acquiring samples of contaminants from surfaces and suspending the samples in liquids. (Thereafter, the liquids can be dispensed, in controlled volumes, into scientific instruments for analysis of the contaminants.) The swab device is designed so as not to introduce additional contamination and to facilitate, simplify, and systematize the dispensing of controlled volumes of liquid into analytical instruments. The swab device is a single apparatus into which are combined all the equipment and materials needed for sampling surface contamination. The swab device contains disposable components stacked together on a nondisposable dispensing head. One of the disposable components is a supply cartridge holding a sufficient volume of liquid for one complete set of samples. (The liquid could be clean water or another suitable solvent, depending on the application.) This supply of liquid is sealed by Luer valves. At the beginning of a sampling process, the user tears open a sealed bag containing the supply cartridge. A tip on the nondisposable dispensing head is engaged with a Luer valve on one end of the supply cartridge and rotated, locking the supply cartridge on the dispensing head and opening the valve. The swab tip includes a fabric swab that is wiped across the surface of interest to acquire a sample. A sealed bag containing a disposable dispensing tip is then opened, and the swab tip is pushed into the dispensing tip until seated. The dispensing head contains a piston that passes through a spring-loaded lip seal. The air volume displaced by this piston forces the liquid out of the supply cartridge, over the swab, and into the dispensing tip. The piston is manually cycled to enforce oscillation of the air volume and thereby to cause water to flow to wash contaminants from the swab and cause the resulting liquid suspension of contaminants to flow into the dispensing tip. After several cycles to ensure adequate mixing, liquid containing the suspended contaminant sample is dispensed. The disposable components are then removed from the dispensing head, which may then be reused with a fresh set of disposable components.
NASA Astrophysics Data System (ADS)
Sharma, Samriti; Sandarve, Sharma, Amit K.; Sharma, Meena
2018-05-01
For the investigation of interactions of L-leucine in aqueous solutions of an ionic liquid (1-butyl-3-methylimidazolium tetra fluoroborate [Bmim][BF4]) at atmospheric pressure over a temperature range of (293.15K to 313.16K), we use the volumetric approach. By using the density data we have calculated the apparent molar volume, VΦ, limiting apparent molar volume, V0Φ, the slope, Sv, partial molar volume of transfer, V0Φ,tr. The values of these acoustical parameters have been used for the interpretation of different interactions like hydrophilic-hydrophilic, hydrophilic-hydrophobic, ion hydrophilic, solute-solvent and solute-solute interactions in the amino acid and ionic liquid solutions.
Dunster, Kimble R; Davies, Mark W; Fraser, John F
2007-01-01
Background Perfluorocarbon (PFC) vapour in the expired gases during partial liquid ventilation should be prevented from entering the atmosphere and recovered for potential reuse. This study aimed to determine how much PFC liquid could be recovered using a conventional humidified neonatal ventilator with chilled condensers in place of the usual expiratory ventilator circuit and whether PFC liquid could be recovered when using the chilled condensers at the ventilator exhaust outlet. Methods Using a model lung, perfluorocarbon vapour loss during humidified partial liquid ventilation of a 3.5 kg infant was approximated. For each test 30 mL of FC-77 was infused into the model lung. Condensers were placed in the expiratory limb of the ventilator circuit and the amounts of PFC (FC-77) and water recovered were measured five times. This was repeated with the condensers placed at the ventilator exhaust outlet. Results When the condensers were used as the expiratory limb, the mean (± SD) volume of FC77 recovered was 16.4 mL (± 0.18 mL). When the condensers were connected to the ventilator exhaust outlet the mean (± SD) volume of FC-77 recovered was 7.6 mL (± 1.14 mL). The volume of FC-77 recovered was significantly higher when the condenser was used as an expiratory limb. Conclusion Using two series connected condensers in the ventilator expiratory line 55% of PFC liquid (FC-77) can be recovered during partial liquid ventilation without altering the function of the of the ventilator circuit. This volume of PFC recovered was just over twice that recovered with the condensers connected to the ventilator exhaust outlet. PMID:17537270
Development and Design of Zero-g Liquid Quantity Gauge for Solar Thermal Vehicle
NASA Technical Reports Server (NTRS)
Dodge, Franklin T.; Green, Steven T.; Petullo, Steven P.; VanDresar, Neil T.
2002-01-01
The development and design of a cryogenic liquid quantity gauge for zero-gravity (zero-g) applications are described. The gauge, named the compression mass gauge (CMG), operates on the principle of slightly changing the volume of the tank by an oscillating bellows. The resulting pressure change is measured and used to predict the volume of vapor in the tank, from which the volume of liquid is computed. For each gauging instance, pressures are measured for several different bellows frequencies to enable minor real-gas effects to be quantified and thereby to obtain a gauging accuracy of 11 percent of tank volume. The CMG has been selected by NASA's Future-X program for a flight demonstration on the United States Air Force-Boeing Solar Orbit Transfer Vehicle Space Experiment (SOTVSE). This report reviews the design trade studies needed for the CMG to satisfy the SOTVSE limitations on its power, volume, and mass and also describes the mechanical design of the CMG.
High-resolution three-dimensional magnetic resonance imaging of mouse lung in situ.
Scadeng, Miriam; Rossiter, Harry B; Dubowitz, David J; Breen, Ellen C
2007-01-01
This study establishes a method for high-resolution isotropic magnetic resonance (MR) imaging of mouse lungs using tracheal liquid-instillation to remove MR susceptibility artifacts. C57BL/6J mice were instilled sequentially with perfluorocarbon and phosphate-buffered saline to an airway pressure of 10, 20, or 30 cm H2O. Imaging was performed in a 7T MR scanner using a 2.5-cm Quadrature volume coil and a 3-dimensional (3D) FLASH imaging sequence. Liquid-instillation removed magnetic susceptibility artifacts and allowed lung structure to be viewed at an isotropic resolution of 78-90 microm. Instilled liquid and modeled lung volumes were well correlated (R = 0.92; P < 0.05) and differed by a constant tissue volume (220 +/- 92 microL). 3D image renderings allowed differences in structural dimensions (volumes and areas) to be accurately measured at each inflation pressure. These data demonstrate the efficacy of pulmonary liquid instillation for in situ high-resolution MR imaging of mouse lungs for accurate measurement of pulmonary airway, parenchymal, and vascular structures.
Yoshida, Hiroyuki; Miura, Yusuke; Tokuoka, Kazuki; Suzuki, Satoshi; Fujii, Akihiko; Ozaki, Masanori
2008-11-10
A controlled helix pitch modulation in the in-plane direction of a planarly aligned cholesteric liquid crystal cell is demonstrated by using photopolymerizable cholesteric liquid crystals. By fabricating artificial domains with a closed volume via two-photon excitation laser-lithography, the degree of pitch modulation could be controlled by adjusting the surface area to volume ratio of the domain. A pitch modulation of over 60 nm was realized by designing the shape of the artificial domain.
IMPROVEMENTS IN LIQUID-LIQUID EXTRACTION APPARATUS
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1961-06-28
A description is given of a liquid-liquid extraction apparatus and of the method of effecting a net transportation in opposed directions of a heavy liquid and a light liquid. The apparatus consists of a plurality of series- connected ves sels, inlet and outlet means for the phases at the ends, and a pulsing means. The upper part of one vessel is joined to the lower part of the next vessel by one connection line or a plurality of parallel-connected lines. The lower part of the second vessel is below the upper part of the first vessel. The volume of eachmore » connection line is less than or the same as the volume displaced by one stroke of the pulsing means. The method is characterized in that a mixture of both liquids is caused to flow to and fro between adjacent vessels through the connection lines which joins the vessels. (N.W.R.)« less
Backe, Will J.; Ort, Christoph; Brewer, Alex J.; Field, Jennifer A.
2014-01-01
A new method was developed for the analysis of natural and synthetic androgenic steroids and their selected metabolites in aquatic environmental matrices using direct large-volume injection (LVI) high performance liquid chromatography (HPLC) tandem mass spectrometry (MS/MS). Method accuracy ranged from 88 to 108% for analytes with well-matched internal standards. Precision, quantified by relative standard deviation (RSD), was less than 12%. Detection limits for the method ranged from 1.2 to 360 ng/L. The method was demonstrated on a series of 1-hr composite wastewater influent samples collected over a day with the purpose of assessing temporal profiles of androgen loads in wastewater. Testosterone, androstenedione, boldenone, and nandrolone were detected in the sample series at concentrations up to 290 ng/L and loads up to 535 mg. Boldenone, a synthetic androgen, had a temporal profile that was strongly correlated to testosterone, a natural human androgen, suggesting its source may be endogenous. An analysis of the sample particulate fraction revealed detectable amounts of sorbed testosterone and androstenedione. Androstenedione sorbed to the particulate fraction accounted for an estimated five to seven percent of the total androstenedione mass. PMID:21391574
Backe, Will J; Ort, Christoph; Brewer, Alex J; Field, Jennifer A
2011-04-01
A new method was developed for the analysis of natural and synthetic androgenic steroids and their selected metabolites in aquatic environmental matrixes using direct large-volume injection (LVI) high-performance liquid chromatography (HPLC) tandem mass spectrometry (MS/MS). Method accuracy ranged from 87.6 to 108% for analytes with well-matched internal standards. Precision, quantified by relative standard deviation (RSD), was less than 12%. Detection limits for the method ranged from 1.2 to 360 ng/L. The method was demonstrated on a series of 1 h composite wastewater influent samples collected over a day with the purpose of assessing temporal profiles of androgen loads in wastewater. Testosterone, androstenedione, boldenone, and nandrolone were detected in the sample series at concentrations up to 290 ng/L and loads up to 535 mg/h. Boldenone, a synthetic androgen, had a temporal profile that was strongly correlated to testosterone, a natural human androgen, suggesting its source may be endogenous. An analysis of the sample particulate fraction revealed detectable amounts of sorbed testosterone and androstenedione. Androstenedione sorbed to the particulate fraction accounted for an estimated 5 to 7% of the total androstenedione mass.
ρ-VOF: An interface sharpening method for gas-liquid flow simulation
NASA Astrophysics Data System (ADS)
Wang, Jiantao; Liu, Gang; Jiang, Xiong; Mou, Bin
2018-05-01
The study on simulation of compressible gas-liquid flow remains open. Popular methods are either confined to incompressible flow regime, or inevitably induce smear of the free interface. A new finite volume method for compressible two-phase flow simulation is contributed for this subject. First, the “heterogeneous equilibrium” assumption is introduced to the control volume, by hiring free interface reconstruction technology, the distribution of each component in the control volume is achieved. Next, AUSM+-up (advection upstream splitting method) scheme is employed to calculate the convective fluxes and pressure fluxes, with the contact discontinuity characteristic considered, followed by the update of the whole flow field. The new method features on density-based pattern and interface reconstruction technology from VOF (volume of fluid), thus we name it “ρ-VOF method”. Inherited from AUSM families and VOF, ρ-VOF behaves as an all-speed method, capable of simulating shock in gas-liquid flow, and preserving the sharpness of the free interface. Gas-liquid shock tube is simulated to evaluate the method, from which good agreement is obtained between the predicted results and those of the cited literature, meanwhile, sharper free interface is identified. Finally, the capability and validity of ρ-VOF method can be concluded in compressible gas-liquid flow simulation.
Volume requirements for aerated mud drilling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guo, B.; Rajtar, J.M.
1995-09-01
Aerated mud drilling has been recognized as having many advantages over conventional mud drilling, such ass higher penetration rate, less formation damage, minimized lost circulation, and lower drilling cost. In some areas, the use of aerated mud as a circulating medium for drilling oil and gas wells is becoming an attractive practice. Maintaining an optimum combination of liquid and air flow rates is important in aerated drilling operations. However, most drilling operators are unclear on what constitutes the ``optimum combination of the liquid and air flow rates.`` Guo et al. presented a mathematical approach to determining the flowing bottomhole pressuremore » (BHP) for aerated mud drilling. This paper addresses the use of Guo et al.`s mathematical model to determine liquid and air volume requirements considering wellbore stability, pipe sticking, and formation damage as well as the cuttings-carry capacity of the aerated mud. For a formation-damage-prevention point of view, the liquid fraction in the fluid stream should e as low as possible. However, a sufficient mud flow rate is always required to make the hole stable and to maintain the cuttings-carrying capacity of the aerated mud without injecting much air volume. This paper provides a simple approach to determining the liquid and air volume requirements for aerated mud drilling.« less
Quantitative tomographic measurements of opaque multiphase flows
DOE Office of Scientific and Technical Information (OSTI.GOV)
GEORGE,DARIN L.; TORCZYNSKI,JOHN R.; SHOLLENBERGER,KIM ANN
2000-03-01
An electrical-impedance tomography (EIT) system has been developed for quantitative measurements of radial phase distribution profiles in two-phase and three-phase vertical column flows. The EIT system is described along with the computer algorithm used for reconstructing phase volume fraction profiles. EIT measurements were validated by comparison with a gamma-densitometry tomography (GDT) system. The EIT system was used to accurately measure average solid volume fractions up to 0.05 in solid-liquid flows, and radial gas volume fraction profiles in gas-liquid flows with gas volume fractions up to 0.15. In both flows, average phase volume fractions and radial volume fraction profiles from GDTmore » and EIT were in good agreement. A minor modification to the formula used to relate conductivity data to phase volume fractions was found to improve agreement between the methods. GDT and EIT were then applied together to simultaneously measure the solid, liquid, and gas radial distributions within several vertical three-phase flows. For average solid volume fractions up to 0.30, the gas distribution for each gas flow rate was approximately independent of the amount of solids in the column. Measurements made with this EIT system demonstrate that EIT may be used successfully for noninvasive, quantitative measurements of dispersed multiphase flows.« less
Lai, Xian-Wen; Sun, Dai-Li; Ruan, Chun-Qiang; Zhang, He; Liu, Cheng-Lan
2014-01-01
A novel, simple, and rapid method is presented for the analysis of aflatoxin B1, aflatoxin B2, and ochratoxin A in rice samples by dispersive liquid-liquid microextraction combined with LC and fluorescence detection. After extraction of the rice samples with a mixture of acetonitrile/water/acetic acid, mycotoxins were rapidly partitioned into a small volume of organic solvent (chloroform) by dispersive liquid-liquid microextraction. The three mycotoxins were simultaneously determined by LC with fluorescence detection after precolumn derivatization for aflatoxin B1 and B2. Parameters affecting both extraction and dispersive liquid-liquid microextraction procedures, including the extraction solvent, the type and volume of extractant, the volume of dispersive solvent, the addition of salt, the pH and the extraction time, were optimized. The optimized protocol provided an enrichment factor of approximately 1.25 and with detection of limits (0.06-0.5 μg/kg) below the maximum levels imposed by current regulations for aflatoxins and ochratoxin A. The mean recovery of three mycotoxins ranged from 82.9-112%, with a RSD less than 7.9% in all cases. The method was successfully applied to measure mycotoxins in commercial rice samples collected from local supermarkets in China. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Mowry, C.D.; Blair, D.S.; Rodacy, P.J.; Reber, S.D.
1999-07-13
An apparatus and process for the continuous, near real-time monitoring of low-level concentrations of organic compounds in a liquid, and, more particularly, a water stream. A small liquid volume of flow from a liquid process stream containing organic compounds is diverted by an automated process to a heated vaporization capillary where the liquid volume is vaporized to a gas that flows to an automated gas chromatograph separation column to chromatographically separate the organic compounds. Organic compounds are detected and the information transmitted to a control system for use in process control. Concentrations of organic compounds less than one part per million are detected in less than one minute. 7 figs.
Controllable picoliter pipetting using hydrophobic microfluidic valves
NASA Astrophysics Data System (ADS)
Zhang, M.; Huang, J.; Qian, X.; Mi, S.; Wang, X.
2017-06-01
A picoliter pipetting technique using the microfluidic method is presented. Utilizing the hydrophobic self-assembled monolayer films patterned in microchannels as pressure-controlled valves, a small volume of liquid can be separated by a designed channel trap and then ejected from the channel end at a higher pressure. The liquid trap section is composed of a T-shaped channel junction and a hydrophobic patch. The liquid volume can be precisely controlled by varying the distance of the hydrophobic patch from the T-junction. By this means, liquid less than 100 pl can be separated and pipetted. The developed device is potentially useful for sample dispensing in biological, medical, and chemical applications.
Mowry, Curtis D.; Blair, Dianna S.; Rodacy, Philip J.; Reber, Stephen D.
1999-01-01
An apparatus and process for the continuous, near real-time monitoring of low-level concentrations of organic compounds in a liquid, and, more particularly, a water stream. A small liquid volume of flow from a liquid process stream containing organic compounds is diverted by an automated process to a heated vaporization capillary where the liquid volume is vaporized to a gas that flows to an automated gas chromatograph separation column to chromatographically separate the organic compounds. Organic compounds are detected and the information transmitted to a control system for use in process control. Concentrations of organic compounds less than one part per million are detected in less than one minute.
Code of Federal Regulations, 2011 CFR
2011-07-01
... concentrations shall be determined on a weight-per-weight basis (e.g., milligrams per kilogram), or for liquids, on a weight-per-volume basis (e.g., milligrams per liter) if the density of the liquid is also... µg/100 cm2. (4) PCBs can be found in liquid, non-liquid and multi-phasic (combinations of liquid and...
Nonlinear oscillations of inviscid free drops
NASA Technical Reports Server (NTRS)
Patzek, T. W.; Benner, R. E., Jr.; Basaran, O. A.; Scriven, L. E.
1991-01-01
The present analysis of free liquid drops' inviscid oscillations proceeds through solution of Bernoulli's equation to obtain the free surface shape and of Laplace's equation for the velocity potential field. Results thus obtained encompass drop-shape sequences, pressure distributions, particle paths, and the temporal evolution of kinetic and surface energies; accuracy is verified by the near-constant drop volume and total energy, as well as the diminutiveness of mass and momentum fluxes across drop surfaces. Further insight into the nature of oscillations is provided by Fourier power spectrum analyses of mode interactions and frequency shifts.
Ultralow noise up-conversion detector and spectrometer for the telecom band.
Shentu, Guo-Liang; Pelc, Jason S; Wang, Xiao-Dong; Sun, Qi-Chao; Zheng, Ming-Yang; Fejer, M M; Zhang, Qiang; Pan, Jian-Wei
2013-06-17
We demonstrate up-conversion single-photon detection for the 1550-nm telecommunications band using a PPLN waveguide, long-wavelength pump, and narrowband filtering using a volume Bragg grating. We achieve total-system detection efficiency of around 30% with noise at the dark-count level of a Silicon APD. Based on the new detector, a single-pixel up-conversion infrared spectrometer with a noise equivalent power of -142 dBm Hz(-1/2) was demonstrated, which was as good as a liquid nitrogen cooled CCD camera.
Foaming volume and foam stability
NASA Technical Reports Server (NTRS)
Ross, Sydney
1947-01-01
A method of measuring foaming volume is described and investigated to establish the critical factors in its operation. Data on foaming volumes and foam stabilities are given for a series of hydrocarbons and for a range of concentrations of aqueous ethylene-glycol solutions. It is shown that the amount of foam formed depends on the machinery of its production as well as on properties of the liquid, whereas the stability of the foam produced, within specified mechanical limitations, is primarily a function of the liquid.
Liquid scintillation sample analysis in microcentrifuge tubes.
Elliott, J C
1993-01-01
Local regulations prohibiting drain disposal of "biodegradable" liquid scintillation cocktails prompted investigation of volume reduction for these materials. Microcentrifuge tubes were used with aqueous and filter media samples of 3H, 14C, 32P, and 125I. Backgrounds, counting efficiencies, figures of merit, and spectral distributions obtained for microcentrifuge tubes compared favorably to conventional vials. Differences in 32P spectra for solid support samples appeared related to filter material and sample volume. Decreases in sample costs and waste volume and disposal costs were approximately 50-75%.
Wetting and elasto-plasticity based sculpture of liquid marbles.
Liu, Jianlin; Zuo, Pingcheng
2016-02-01
As an emerging material with exotic properties, liquid marble holds great potential for such areas as microfluidics, stimuli-responsive sensors, micro-chemical reactors, micro-bioreactors, energy harvesting devices, and mechanical structures. In this study, we mainly concentrate on the mechanical behaviors, such as elasto-plasticity of liquid marble with the decrease of liquid volume. The contact radius with the substrate and Young's contact angle of liquid marble are both measured with the change of water volume, and those of a water droplet are compared. The mechanism for the different responses for liquid marble and water droplet is clarified according to the mechanics analysis. Moreover, it is found that liquid marble can behave like an elasto-plastic material when the particle surface density is big enough. Based upon this fact, liquid marble can be sculpted to all kinds of special shapes as expected. These investigations may cast new light on how to engineer multifunctional materials and devices, which are beneficial to microprinting and micromachining.
Nakamura, T; Hara, H; Ijima, F; Arai, T; Kira, S
1984-03-01
To study the dynamics of pleural liquid, 250 ml of saline labeled with markers were injected into the pleural cavity of anesthetized dogs. For 3 h, liquid volume and concentration of these markers were measured. In a control group of dogs, the turnover rate of pleural liquid was 19.6 +/- 5.6 ml/min and lymphatic flow was 0.58 +/- 0.07 ml/min. In a group of pneumonectomized dogs, the turnover rate and lymphatic flow fell to about one fourth of those in the control group. When the left pulmonary artery was occluded, the turnover rate was halved, but lymphatic flow was not significantly different from that in the control group. These results suggest that the turnover rate of pleural liquid is dependent on the area of contact between pleural liquid and pleura and on the blood flow of the pleura. In addition, it appears that changes in pleural liquid volume are dependent on lymphatic flow.
A new proposal to evaluate the healing of open skin wounds: volumetry.
Paulo, Danilo Nagib Salomão; Fiorot, Antonio Wilson
2011-12-01
To present a new proposal to evaluate the healing of an open subcutaneous and skin wound, which we termed "volumetry". A total of 32 circular wounds were performed in the subcutaneous tissues and skin of four feet of pigs (8 each). Each wound had about 1 cm in diameter and was 0.2 cm deep. Volume was calculated from the wound filled with saline and mass Xantopren. With the aid of a magnifying glass and local lighting, the liquid was dripped with a micropipette inside the wound until complete fullness. Volume repletion was calculated in microliters, corresponding to the volume of the wound. The mass of Xantopren was placed inside the wound to obtain a mold of the lesion. Mold volume was calculated using the formula of the volume of a cylinder closest resembling a geometric figure with mold. The calculation of wound volume was possible with both Xantopren and mold techniques. Volume as calculated by micropipette was 119.37 ± 30.87 microliters while the volume calculated by mold was 122.41 ± 33.90 mm3 (p=0.79). Volumetry in pig feet is simple and reproducible. Volumetry perfomed with saline did not differ from the volumetry with mass Xantopren. This method may be a useful tool to help evaluate the healing of open skin wounds in experimental and clinical research.
Transfer of thermal microwaves in the atmosphere, volume 1
NASA Technical Reports Server (NTRS)
Paris, J. F.
1971-01-01
The Mie theory is used to determine the absorption and scattering properties of liquid hydrometeors at 27 microwave frequencies from 500 MHz to 60 GHz. Based on the Marshall-Palmer distribution of drop sizes, regression equations are developed for the volume absorption coefficient of rain as a function of its temperature and content of liquid water.
Effects of surface anchoring on the electric Frederiks transition in ferronematic systems
NASA Astrophysics Data System (ADS)
Farrokhbin, Mojtaba; Kadivar, Erfan
2016-11-01
The effects of anchoring phenomenon on the electric Frederiks transition threshold field in a nematic liquid crystal doped with ferroelectric nanoparticles are discussed. The polarizability of these nanoparticles in combination with confinement effects cause the drastic effects on the ferronematic systems. This study is based on Frank free energy and Rapini-Papoular surface energy for ferronematic liquid crystal having finite anchoring condition. In the case of different anchoring boundary conditions, the Euler-Lagrange equation of the total free energy is numerically solved by using the finite difference method together with the relaxation method and Maxwell construction to select the physical solutions and therefore investigate the effects of different anchoring strengths on the Frederiks transition threshold field. Maxwell construction method is employed to select three periodic solutions for nematic liquid crystal director at the interfaces of a slab. In the interval from zero to half- π, there is only one solution for the director orientation. In this way, NLC director rotates toward the normal to the surface as the applied electric field increases at the walls. Our numerical results illustrate that above Frederiks transition and in the intermediate anchoring strength, nematic molecules illustrate the different orientation at slab boundaries. We also study the effects of different anchoring strengths, nanoparticle volume fractions and polarizations on the Frederiks transition threshold field. We report that decreasing in the nanoparticle polarization results in the saturation Frederiks threshold. However, this situation does not happen for the nanoparticles volume fraction.
Constantin, Julian Gelman; Schneider, Matthias; Corti, Horacio R
2016-06-09
The glass transition temperature of trehalose, sucrose, glucose, and fructose aqueous solutions has been predicted as a function of the water content by using the free volume/percolation model (FVPM). This model only requires the molar volume of water in the liquid and supercooled regimes, the molar volumes of the hypothetical pure liquid sugars at temperatures below their pure glass transition temperatures, and the molar volumes of the mixtures at the glass transition temperature. The model is simplified by assuming that the excess thermal expansion coefficient is negligible for saccharide-water mixtures, and this ideal FVPM becomes identical to the Gordon-Taylor model. It was found that the behavior of the water molar volume in trehalose-water mixtures at low temperatures can be obtained by assuming that the FVPM holds for this mixture. The temperature dependence of the water molar volume in the supercooled region of interest seems to be compatible with the recent hypothesis on the existence of two structure of liquid water, being the high density liquid water the state of water in the sugar solutions. The idealized FVPM describes the measured glass transition temperature of sucrose, glucose, and fructose aqueous solutions, with much better accuracy than both the Gordon-Taylor model based on an empirical kGT constant dependent on the saccharide glass transition temperature and the Couchman-Karasz model using experimental heat capacity changes of the components at the glass transition temperature. Thus, FVPM seems to be an excellent tool to predict the glass transition temperature of other aqueous saccharides and polyols solutions by resorting to volumetric information easily available.
Fox, James E.; Ahlbrandt, Thomas S.
2002-01-01
The Widyan Basin-Interior Platform Province (2023) ranks 17th in the world, exclusive of the United States, with 62.5 billion barrels of oil equivalent of total petroleum endowment (cumulative production plus remaining petroleum plus estimated mean undiscovered volumes). Mean estimates of undiscovered petroleum for the province, which includes both Paleozoic and Jurassic petroleum systems as well as portions of three additional total petroleum systems from adjacent provinces, are 21.22 billion barrels of oil, 94.75 trillion cubic feet of gas (15.8 billion barrels of oil equivalent), and 6.85 billion barrels of natural gas liquids. The Paleozoic total petroleum system is dominantly gas prone, whereas the volumetrically larger Jurassic total petroleum system is oil prone - resulting in the characterization of the province as an oil province. The discovery maturity for the province is a relatively low 31 percent, meaning that much of the province petroleum potential lies in the future.
Measuring liquid density using Archimedes' principle
NASA Astrophysics Data System (ADS)
Hughes, Stephen W.
2006-09-01
A simple technique is described for measuring absolute and relative liquid density based on Archimedes' principle. The technique involves placing a container of the liquid under test on an electronic balance and suspending a probe (e.g. a glass marble) attached to a length of line beneath the surface of the liquid. If the volume of the probe is known, the density of liquid is given by the difference between the balance reading before and after immersion of the probe divided by the volume of the probe. A test showed that the density of water at room temperature could be measured to an accuracy and precision of 0.01 ± 0.1%. The probe technique was also used to measure the relative density of milk, Coca-Cola, fruit juice, olive oil and vinegar.
Finite element solution of low bond number sloshing
NASA Technical Reports Server (NTRS)
Wohlen, R. L.; Park, A. C.; Warner, D. M.
1975-01-01
The dynamics of liquid propellant in a low Bond number environment which are critical to the design of spacecraft systems with respect to orbital propellant transfer and attitude control system were investigated. Digital computer programs were developed for the determination of liquid free surface equilibrium shape, lateral slosh natural vibration mode shapes, and frequencies for a liquid in a container of arbitrary axisymmetric shape with surface tension forces the same order of magnitude as acceleration forces. A finite volume element representation of the liquid was used for the vibration analysis. The liquid free surface equilibrium shapes were computed for several tanks at various contact angles and ullage volumes. A configuration was selected for vibration analysis and lateral slosh mode shapes and natural frequencies were obtained. Results are documented.
NASA Technical Reports Server (NTRS)
Gluzek, F.; Mokadam, R. G.; To, I. H.; Stanitz, J. D.; Wollschlager, J.
1979-01-01
A rotating, positive displacement vane pump with an integral boost stage was designed to pump saturated liquid oxygen and liquid hydrogen for auxiliary propulsion system of orbit transfer vehicle. This unit is designed to ingest 10% vapor by volume, contamination free liquid oxygen and liquid hydrogen. The final pump configuration and the predicted performance are included.
Partial Molar Volumes of Aqua Ions from First Principles.
Wiktor, Julia; Bruneval, Fabien; Pasquarello, Alfredo
2017-08-08
Partial molar volumes of ions in water solution are calculated through pressures obtained from ab initio molecular dynamics simulations. The correct definition of pressure in charged systems subject to periodic boundary conditions requires access to the variation of the electrostatic potential upon a change of volume. We develop a scheme for calculating such a variation in liquid systems by setting up an interface between regions of different density. This also allows us to determine the absolute deformation potentials for the band edges of liquid water. With the properly defined pressures, we obtain partial molar volumes of a series of aqua ions in very good agreement with experimental values.
ERIC Educational Resources Information Center
Duer, W. C.; And Others
1977-01-01
Discusses comparisons of packing densities derived from known molar volume data of liquids and solutions. Suggests further studies for using assemblies of spheres as models for simple liquids and solutions. (MLH)
Quasi-steady vortical structures in vertically vibrating soap films
NASA Astrophysics Data System (ADS)
Vega, José M.; Higuera, F. J.; Weidman, P. D.
1998-10-01
An analysis of the quasi-steady streaming of the liquid in a vertically vibrated horizontal soap film is reported. The air around the soap film is seen to play a variety of roles: it transmits normal and tangential oscillatory stresses to the film, damps out Marangoni waves, and forces non-oscillatory deflection of the film and tangential motion of the liquid. Non-oscillatory volume forcing originating inside the liquid is also analysed. This forcing dominates the quasi-steady streaming when the excitation frequency is close to the eigenfrequency of a Marangoni mode of the soap film, while both volume forcing in the liquid and surface forcing of the gas on the liquid are important when no Marangoni mode resonates. Different manners by which the combined forcings can induce quasi-steady streaming motion are discussed and some numerical simulations of the quasi-steady liquid flow are presented.
Automatic liquid handling for life science: a critical review of the current state of the art.
Kong, Fanwei; Yuan, Liang; Zheng, Yuan F; Chen, Weidong
2012-06-01
Liquid handling plays a pivotal role in life science laboratories. In experiments such as gene sequencing, protein crystallization, antibody testing, and drug screening, liquid biosamples frequently must be transferred between containers of varying sizes and/or dispensed onto substrates of varying types. The sample volumes are usually small, at the micro- or nanoliter level, and the number of transferred samples can be huge when investigating large-scope combinatorial conditions. Under these conditions, liquid handling by hand is tedious, time-consuming, and impractical. Consequently, there is a strong demand for automated liquid-handling methods such as sensor-integrated robotic systems. In this article, we survey the current state of the art in automatic liquid handling, including technologies developed by both industry and research institutions. We focus on methods for dealing with small volumes at high throughput and point out challenges for future advancements.
Wetting morphologies on randomly oriented fibers.
Sauret, Alban; Boulogne, François; Soh, Beatrice; Dressaire, Emilie; Stone, Howard A
2015-06-01
We characterize the different morphologies adopted by a drop of liquid placed on two randomly oriented fibers, which is a first step toward understanding the wetting of fibrous networks. The present work reviews previous modeling for parallel and touching crossed fibers and extends it to an arbitrary orientation of the fibers characterized by the tilting angle and the minimum spacing distance. Depending on the volume of liquid, the spacing distance between fibers and the angle between the fibers, we highlight that the liquid can adopt three different equilibrium morphologies: 1) a column morphology in which the liquid spreads between the fibers, 2) a mixed morphology where a drop grows at one end of the column or 3) a single drop located at the node. We capture the different morphologies observed using an analytical model that predicts the equilibrium configuration of the liquid based on the geometry of the fibers and the volume of liquid.
The effect of dietary carbohydrate on gastroesophageal reflux disease.
Wu, Keng-Liang; Kuo, Chung-Mou; Yao, Chih-Chien; Tai, Wei-Chen; Chuah, Seng-Kee; Lim, Chee-Sang; Chiu, Yi-Chun
2018-01-12
Acid changes in gastroesophageal reflux with vary component in the food have less been studied, especially carbohydrate. We plan to clarify the effect of different carbohydrate density on low esophageal acid and reflux symptoms of patients with gastroesophgeal reflux disease. Twelve patients (52 ± 12 years old; five female) with gastroesophageal reflux disease were recruited for the prospective crossover study. Each patient was invited for panendoscope, manometry and 24 h pH monitor. The two formulated liquid meal, test meal A: 500 ml liquid meal (containing 84.8 g carbohydrate) and B: same volume liquid meal (but 178.8 g carbohydrate) were randomized supplied as lunch or dinner. Reflux symptoms were recorded. There are significant statistic differences in more Johnson-DeMeester score (p = 0.019), total reflux time (%) (p = 0.028), number of reflux periods (p = 0.026) and longest reflux (p = 0.015) after high carbohydrate diet than low carbohydrate. Total reflux time and number of long reflux periods more than 5 min are significant more after high carbohydrate diet. More acid reflux symptoms are found after high carbohydrate diet. High carbohydrate diet could induce more acid reflux in low esophagus and more reflux symptoms in patients with gastroesophageal reflux disease. Copyright © 2018. Published by Elsevier B.V.
Ruan, Chunqiang; Zhao, Xiang; Liu, Chenglan
2015-09-01
In this study, a simple and low-organic-solvent-consuming method combining an acetonitrile-partitioning extraction procedure followed by "quick, easy, cheap, effective, rugged and safe" cleanup with ionic-liquid-based dispersive liquid-liquid microextraction and high-performance liquid chromatography with diode array detection was developed for the determination of diflubenzuron and chlorbenzuron in grapes and pears. Ionic-liquid-based dispersive liquid-liquid microextraction was performed using the ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate as the extractive solvent and acetonitrile extract as the dispersive solvent. The main factors influencing the efficiency of the dispersive liquid-liquid microextraction were evaluated, including the extractive solvent type and volume and the dispersive solvent volume. The validation parameters indicated the suitability of the method for routine analyses of benzoylurea insecticides in a large number of samples. The relative recoveries at three spiked levels ranged between 98.6 and 109.3% with relative standard deviations of less than 5.2%. The limit of detection was 0.005 mg/kg for the two insecticides. The proposed method was successfully used for the rapid determination of diflubenzuron and chlorbenzuron residues in real fruit samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Lenk, Gabriel; Sandkvist, Sören; Pohanka, Anton; Stemme, Göran; Beck, Olof; Roxhed, Niclas
2015-01-01
DBS samples collected from a fingerprick typically vary in volume and homogeneity and hence make an accurate quantitative analysis of DBS samples difficult. We report a prototype which first defines a precise liquid volume and subsequently stores it to a conventional DBS matrix. Liquid volumes of 2.2 µl ± 7.1% (n = 21) for deionized water and 6.1 µl ± 8.8% (n = 15) for whole blood have been successfully metered and stored in DBS paper. The new method of collecting a defined volume of blood by DBS sampling has the potential to reduce assay bias for the quantitative evaluation of DBS samples while maintaining the simplicity of conventional DBS sampling.
Effects of fluid shear stress on polyelectrolyte multilayers by neutron scattering studies
Singh, Saurabh; Junghans, Ann; Watkins, Erik; ...
2015-02-17
The structure of layer-by-layer (LbL) deposited nanofilm coatings consists of alternating polyethylenimine (PEI) and polystyrenesulfonate (PSS) films deposited on a single crystal quartz substrate. LbL-deposited nanofilms were investigated by neutron reflectomery (NR) in contact with water in the static and fluid shear stress conditions. The fluid shear stress was applied through a laminar flow of the liquid parallel to the quartz/polymer interface in a custom-built solid–liquid interface cell. The scattering length density profiles obtained from NR results of these polyelectrolyte multilayers (PEM), measured under different shear conditions, showed proportional decrease of volume fraction of water hydrating the polymers. For themore » highest shear rate applied (ca. 6800 s –1) the water volume fraction decreased by approximately 7%. The decrease of the volume fraction of water was homogeneous through the thickness of the film. Since there were not any significant changes in the total polymer thickness, it resulted in negative osmotic pressures in the film. The PEM films were compared with the behavior of thin films of thermoresponsive poly(N-isopropylacrylamide) (pNIPAM) deposited via spin-coating. The PEM and pNIPAM differ in their interactions with water molecules, and they showed opposite behaviors under the fluid shear stress. In both cases the polymer hydration was reversible upon the restoration of static conditions. Furthermore, a theoretical explanation is given to explain this difference in the effect of shear on hydration of polymeric thin films.« less
Plexcitonics: Coupled and Plasmon-Exciton Systems with Tailorable Properties
2013-11-14
demonstrated efficient steam generation from aqueous nanoparticles solutions without heating the bulk volume of the liquid. Application in ethanol ...solutions without heating the bulk volume of the liquid. Applications in ethanol distillation and sanitation have been demonstrated. Key Accomplishments...nanoparticle surface. This state-selective population of adsorbate resonances could be exploited to prepare reactants in specific states on nanoparticle
ERIC Educational Resources Information Center
Rittenhouse, Robert K.
Twenty-four profoundly deaf children (7 to 13 years old) from a residential school were presented with conservation problems of liquid, matter, weight, and volume. Analyses of variance showed that age was significant beyond the .01 level and type of task (conservation) at the .25 level. No significant sex effect was found. Differences among means…
Guo, Liang; Tan, Shufang; Li, Xiao; Lee, Hian Kee
2016-03-18
An automated procedure, combining low density solvent based solvent demulsification dispersive liquid-liquid microextraction (DLLME) with gas chromatography-mass spectrometry analysis, was developed for the determination of polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. Capitalizing on a two-rail commercial autosampler, fast solvent transfer using a large volume syringe dedicated to the DLLME process, and convenient extract collection using a small volume microsyringe for better GC performance were enabled. Extraction parameters including the type and volume of extraction solvent, the type and volume of dispersive solvent and demulsification solvent, extraction and demulsification time, and the speed of solvent injection were investigated and optimized. Under the optimized conditions, the linearity ranged from 0.1 to 50 μg/L, 0.2 to 50 μg/L, and 0.5 to 50 μg/L, depending on the analytes. Limits of detection were determined to be between 0.023 and 0.058 μg/L. The method was applied to determine PAHs in environmental water samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Fu, Boqiang; Wang, Jing; Roturier, Jean Michel; Tang, Zhiyu; Li, Huan; Wei, Guangyan
2008-01-01
An interlaboratory study was conducted in China to validate the modified AOAC Official Method 2001.03 for the determination of total dietary fiber (TDF) in foods containing resistant maltodextrin (RMD), which will be adopted as the National Standard Method of China. The kind of buffer solution, the volume of filtrate evaporation, the volume of eluent for desalting and residual solution after evaporation, etc. were modified, which had been proved to have acceptable accuracy and precision in the routine assay. TDF contents in 3 representative foods and 2 kinds of RMD ingredient (i.e., NUTRIOSE 06 and NUTRIOSE 10) were measured using the modified method in 6 eligible laboratories representing commercial, industrial, and governmental laboratories in China. The results of the interlaboratory study indicated that the intralaboratory repeatability, interlaboratory reproducibility, and precision of the modified method are adequate for reliable analysis of TDF in food containing RMD, as well as resistant dextrin. Compared to AOAC Official Method 2001.03, the modified method is time- and cost-saving.
Robotic liquid handling and automation in epigenetics.
Gaisford, Wendy
2012-10-01
Automated liquid-handling robots and high-throughput screening (HTS) are widely used in the pharmaceutical industry for the screening of large compound libraries, small molecules for activity against disease-relevant target pathways, or proteins. HTS robots capable of low-volume dispensing reduce assay setup times and provide highly accurate and reproducible dispensing, minimizing variation between sample replicates and eliminating the potential for manual error. Low-volume automated nanoliter dispensers ensure accuracy of pipetting within volume ranges that are difficult to achieve manually. In addition, they have the ability to potentially expand the range of screening conditions from often limited amounts of valuable sample, as well as reduce the usage of expensive reagents. The ability to accurately dispense lower volumes provides the potential to achieve a greater amount of information than could be otherwise achieved using manual dispensing technology. With the emergence of the field of epigenetics, an increasing number of drug discovery companies are beginning to screen compound libraries against a range of epigenetic targets. This review discusses the potential for the use of low-volume liquid handling robots, for molecular biological applications such as quantitative PCR and epigenetics.
Han, Jeong-Hwan; Oda, Takuji
2018-04-14
The performance of exchange-correlation functionals in density-functional theory (DFT) calculations for liquid metal has not been sufficiently examined. In the present study, benchmark tests of Perdew-Burke-Ernzerhof (PBE), Armiento-Mattsson 2005 (AM05), PBE re-parameterized for solids, and local density approximation (LDA) functionals are conducted for liquid sodium. The pair correlation function, equilibrium atomic volume, bulk modulus, and relative enthalpy are evaluated at 600 K and 1000 K. Compared with the available experimental data, the errors range from -11.2% to 0.0% for the atomic volume, from -5.2% to 22.0% for the bulk modulus, and from -3.5% to 2.5% for the relative enthalpy depending on the DFT functional. The generalized gradient approximation functionals are superior to the LDA functional, and the PBE and AM05 functionals exhibit the best performance. In addition, we assess whether the error tendency in liquid simulations is comparable to that in solid simulations, which would suggest that the atomic volume and relative enthalpy performances are comparable between solid and liquid states but that the bulk modulus performance is not. These benchmark test results indicate that the results of liquid simulations are significantly dependent on the exchange-correlation functional and that the DFT functional performance in solid simulations can be used to roughly estimate the performance in liquid simulations.
NASA Astrophysics Data System (ADS)
Han, Jeong-Hwan; Oda, Takuji
2018-04-01
The performance of exchange-correlation functionals in density-functional theory (DFT) calculations for liquid metal has not been sufficiently examined. In the present study, benchmark tests of Perdew-Burke-Ernzerhof (PBE), Armiento-Mattsson 2005 (AM05), PBE re-parameterized for solids, and local density approximation (LDA) functionals are conducted for liquid sodium. The pair correlation function, equilibrium atomic volume, bulk modulus, and relative enthalpy are evaluated at 600 K and 1000 K. Compared with the available experimental data, the errors range from -11.2% to 0.0% for the atomic volume, from -5.2% to 22.0% for the bulk modulus, and from -3.5% to 2.5% for the relative enthalpy depending on the DFT functional. The generalized gradient approximation functionals are superior to the LDA functional, and the PBE and AM05 functionals exhibit the best performance. In addition, we assess whether the error tendency in liquid simulations is comparable to that in solid simulations, which would suggest that the atomic volume and relative enthalpy performances are comparable between solid and liquid states but that the bulk modulus performance is not. These benchmark test results indicate that the results of liquid simulations are significantly dependent on the exchange-correlation functional and that the DFT functional performance in solid simulations can be used to roughly estimate the performance in liquid simulations.
Io: Loki Patera as a Magma Sea
NASA Technical Reports Server (NTRS)
Matson, Dennis L.; Davies, Ashley Gerard; Veeder, Glenn J.; Rathbun, Julie A.; Johnson, Torrence V.; Castillo, Julie C.
2006-01-01
We develop a physical model for Loki Patera as a magma sea. We calculate the total volume of magma moving through the Loki Patera volcanic system every resurfacing cycle (approx.540 days) and the resulting variation in thermal emission. The rate of magma solidification at times reaches 3 x 10(exp 6) kg per second, with a total solidified volume averaging 100 cu km per year. A simulation of gas physical chemistry evolution yields the crust porosity profile and the timescale when it will become dense enough to founder in a manner consistent with observations. The Loki Patera surface temperature distribution shows that different areas are at different life cycle stages. On a regional scale, however, there can be coordinated activity, indicated by the wave of thermal change which progresses from Loki Patera's SW quadrant toward the NE at a rate of approx.1 km per day. Using the observed surface temperature distribution, we test several mechanisms for resurfacing Loki Patera, finding that resurfacing with lava flows is not realistic. Only the crustal foundering process is consistent with observations. These tests also discovered that sinking crust has a 'heat deficit' which promotes the solidification of additional magma onto the sinking plate ("bulking up"). In the limiting case, the mass of sinking material can increase to a mass of approx.3 times that of the foundering plate. With all this solid matter sinking, there is a compensating upward motion in the liquid magma. This can be in excess of 2 m per year. In this manner, solid-liquid convection is occurring in the sea.
Hairy root culture in a liquid-dispersed bioreactor: characterization of spatial heterogeneity.
Williams, G R; Doran, P M
2000-01-01
A liquid-dispersed reactor equipped with a vertical mesh cylinder for inoculum support was developed for culture of Atropa belladonna hairy roots. The working volume of the culture vessel was 4.4 L with an aspect ratio of 1.7. Medium was dispersed as a spray onto the top of the root bed, and the roots grew radially outward from the central mesh cylinder to the vessel wall. Significant benefits in terms of liquid drainage and reduced interstitial liquid holdup were obtained using a vertical rather than horizontal support structure for the biomass and by operating the reactor with cocurrent air and liquid flow. With root growth, a pattern of spatial heterogeneity developed in the vessel. Higher local biomass densities, lower volumes of interstitial liquid, lower sugar concentrations, and higher root atropine contents were found in the upper sections of the root bed compared with the lower sections, suggesting a greater level of metabolic activity toward the top of the reactor. Although gas-liquid oxygen transfer to the spray droplets was very rapid, there was evidence of significant oxygen limitations in the reactor. Substantial volumes of non-free-draining interstitial liquid accumulated in the root bed. Roots near the bottom of the vessel trapped up to 3-4 times their own weight in liquid, thus eliminating the advantages of improved contact with the gas phase offered by liquid-dispersed culture systems. Local nutrient and product concentrations in the non-free-draining liquid were significantly different from those in the bulk medium, indicating poor liquid mixing within the root bed. Oxygen enrichment of the gas phase improved neither growth nor atropine production, highlighting the greater importance of liquid-solid compared with gas-liquid oxygen transfer resistance. The absence of mechanical or pneumatic agitation and the tendency of the root bed to accumulate liquid and impede drainage were identified as the major limitations to reactor performance. Improved reactor operating strategies and selection or development of root lines offering minimal resistance to liquid flow and low liquid retention characteristics are possible solutions to these problems.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-22
... the NYSE's total intraday adding liquidity in each such security for that month; \\7\\ \\7\\ The NYSE total intraday adding liquidity is totaled monthly and includes all NYSE adding liquidity, excluding... more than 15% but less than or equal to 30% of the NYSE's total intraday adding liquidity in each such...
Theoretical analysis of mixing in liquid clouds – Part 3: Inhomogeneous mixing
Pinsky, Mark; Khain, Alexander; Korolev, Alexei
2016-07-28
An idealized diffusion–evaporation model of time-dependent mixing between a cloud volume and a droplet-free volume is analyzed. The initial droplet size distribution (DSD) in the cloud volume is assumed to be monodisperse. It is shown that evolution of the microphysical variables and the final equilibrium state are unambiguously determined by two non-dimensional parameters. The first one is the potential evaporation parameter R, proportional to the ratio of the saturation deficit to the liquid water content in the cloud volume, that determines whether the equilibrium state is reached at 100 % relative humidity, or is characterized by a complete evaporation ofmore » cloud droplets. The second parameter Da is the Damkölher number equal to the ratio of the characteristic mixing time to the phase relaxation time. Parameters R and Da determine the type of mixing. The results are analyzed within a wide range of values of R and Da. It is shown that there is no pure homogeneous mixing, since the first mixing stage is always inhomogeneous. The mixing type can change during the mixing process. Any mixing type leads to formation of a tail of small droplets in DSD and, therefore, to DSD broadening that depends on Da. At large Da, the final DSD dispersion can be as large as 0.2. The total duration of mixing varies from several to 100 phase relaxation time periods, depending on R and Da. The definitions of homogeneous and inhomogeneous types of mixing are reconsidered and clarified, enabling a more precise delimitation between them. The paper also compares the results obtained with those based on the classic mixing concepts.« less
Theoretical analysis of mixing in liquid clouds – Part 3: Inhomogeneous mixing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pinsky, Mark; Khain, Alexander; Korolev, Alexei
An idealized diffusion–evaporation model of time-dependent mixing between a cloud volume and a droplet-free volume is analyzed. The initial droplet size distribution (DSD) in the cloud volume is assumed to be monodisperse. It is shown that evolution of the microphysical variables and the final equilibrium state are unambiguously determined by two non-dimensional parameters. The first one is the potential evaporation parameter R, proportional to the ratio of the saturation deficit to the liquid water content in the cloud volume, that determines whether the equilibrium state is reached at 100 % relative humidity, or is characterized by a complete evaporation ofmore » cloud droplets. The second parameter Da is the Damkölher number equal to the ratio of the characteristic mixing time to the phase relaxation time. Parameters R and Da determine the type of mixing. The results are analyzed within a wide range of values of R and Da. It is shown that there is no pure homogeneous mixing, since the first mixing stage is always inhomogeneous. The mixing type can change during the mixing process. Any mixing type leads to formation of a tail of small droplets in DSD and, therefore, to DSD broadening that depends on Da. At large Da, the final DSD dispersion can be as large as 0.2. The total duration of mixing varies from several to 100 phase relaxation time periods, depending on R and Da. The definitions of homogeneous and inhomogeneous types of mixing are reconsidered and clarified, enabling a more precise delimitation between them. The paper also compares the results obtained with those based on the classic mixing concepts.« less
Code of Federal Regulations, 2011 CFR
2011-07-01
... interest. (g) Liquefied petroleum products means natural gas liquid products including the following... liquids and nonhydrocarbon gases. (3) Of liquefied petroleum products means the volume of natural gas liquids produced from reservoir gas and liquefied at surface separators, field facilities, or gas...
Novel Liquid Sorbent C02 Removal System for Microgravity Applications
NASA Technical Reports Server (NTRS)
Rogers, Tanya; Westover, Shayne; Graf, John
2017-01-01
Removing Carbon Dioxide (CO2) from a spacecraft environment for deep space exploration requires a robust system that is low in weight, power, and volume. Current state-of-the-art microgravity compatible CO2 removal systems, such as the carbon dioxide removal assembly (CDRA), utilize solid sorbents that demand high power usage due to high desorption temperatures and a large volume to accommodate for their comparatively low capacity for CO2. Additionally, solid sorbent systems contain several mechanical components that significantly reduce reliability and contribute to a large overall mass. A liquid sorbent based system has been evaluated as an alternative is proposed to consume 65% less power, weight, and volume than solid based CO2 scrubbers. This paper presents the design of a liquid sorbent CO2 removal system for microgravity applications.
Kletetschka, Gunther; Hruba, Jolana
2015-01-01
Abstract Three issues are critical for successful cryopreservation of multicellular material: gases dissolved in liquid, thermal conductivity of the tissue, and localization of microstructures. Here we show that heat distribution is controlled by the gas amount dissolved in liquids and that when changing the liquid into solid, the dissolved gases either form bubbles due to the absence of space in the lattice of solids and/or are migrated toward the concentrated salt and sugar solution at the cost of amount of heat required to be removed to complete a solid-state transition. These factors affect the heat distribution in the organs to be cryopreserved. We show that the gas concentration issue controls fracturing of ice when freezing. There are volumetric changes not only when changing the liquid into solid (volume increases) but also reduction of the volume when reaching lower temperatures (volume decreases). We discuss these issues parallel with observations of the cryosurvivability of multicellular organisms, tardigrades, and discuss their analogy for cryopreservation of large organs. PMID:26309797
A Direct Numerical Simulation of a Temporally Evolving Liquid-Gas Turbulent Mixing Layer
NASA Astrophysics Data System (ADS)
Vu, Lam Xuan; Chiodi, Robert; Desjardins, Olivier
2017-11-01
Air-blast atomization occurs when streams of co-flowing high speed gas and low speed liquid shear to form drops. Air-blast atomization has numerous industrial applications from combustion engines in jets to sprays used for medical coatings. The high Reynolds number and dynamic pressure ratio of a realistic air-blast atomization case requires large eddy simulation and the use of multiphase sub-grid scale (SGS) models. A direct numerical simulations (DNS) of a temporally evolving mixing layer is presented to be used as a base case from which future multiphase SGS models can be developed. To construct the liquid-gas mixing layer, half of a channel flow from Kim et al. (JFM, 1987) is placed on top of a static liquid layer that then evolves over time. The DNS is performed using a conservative finite volume incompressible multiphase flow solver where phase tracking is handled with a discretely conservative volume of fluid method. This study presents statistics on velocity and volume fraction at different Reynolds and Weber numbers.
Kletetschka, Gunther; Hruba, Jolana
2015-01-01
Three issues are critical for successful cryopreservation of multicellular material: gases dissolved in liquid, thermal conductivity of the tissue, and localization of microstructures. Here we show that heat distribution is controlled by the gas amount dissolved in liquids and that when changing the liquid into solid, the dissolved gases either form bubbles due to the absence of space in the lattice of solids and/or are migrated toward the concentrated salt and sugar solution at the cost of amount of heat required to be removed to complete a solid-state transition. These factors affect the heat distribution in the organs to be cryopreserved. We show that the gas concentration issue controls fracturing of ice when freezing. There are volumetric changes not only when changing the liquid into solid (volume increases) but also reduction of the volume when reaching lower temperatures (volume decreases). We discuss these issues parallel with observations of the cryosurvivability of multicellular organisms, tardigrades, and discuss their analogy for cryopreservation of large organs.
NASA Technical Reports Server (NTRS)
VanDresar, Neil T.; Zimmerli, Gregory A.
2014-01-01
Results are presented for pressure-volume-temperature (PVT) gauging of a liquid oxygen/liquid nitrogen tank pressurized with gaseous helium that was supplied by a high-pressure cryogenic tank simulating a cold helium supply bottle on a spacecraft. The fluid inside the test tank was kept isothermal by frequent operation of a liquid circulation pump and spray system, and the propellant tank was suspended from load cells to obtain a high-accuracy reference standard for the gauging measurements. Liquid quantity gauging errors of less than 2 percent of the tank volume were obtained when quasi-steady-state conditions existed in the propellant and helium supply tanks. Accurate gauging required careful attention to, and corrections for, second-order effects of helium solubility in the liquid propellant plus differences in the propellant/helium composition and temperature in the various plumbing lines attached to the tanks. On the basis of results from a helium solubility test, a model was developed to predict the amount of helium dissolved in the liquid as a function of cumulative pump operation time. Use of this model allowed correction of the basic PVT gauging calculations and attainment of the reported gauging accuracy. This helium solubility model is system specific, but it may be adaptable to other hardware systems.
NASA Astrophysics Data System (ADS)
Khan, M. F.; Miriyala, N.; Lee, J.; Hassanpourfard, M.; Kumar, A.; Thundat, T.
2016-05-01
Lab-on-a-Chip compatible techniques for thermal characterization of miniaturized volumes of liquid analytes are necessary in applications such as protein blotting, DNA melting, and drug development, where samples are either rare or volume-limited. We developed a closed-chamber calorimeter based on a bimaterial microchannel cantilever (BMC) for sub-nanoliter level thermal analysis. When the liquid-filled BMC is irradiated with infrared (IR) light at a specific wavelength, the IR absorption by the liquid analyte results in localized heat generation and the subsequent deflection of the BMC, due to a thermal expansion mismatch between the constituent materials. The time constant of the deflection, which is dependent upon the heat capacity of the liquid analyte, can be directly measured by recording the time-dependent bending of the BMC. We have used the BMC to quantitatively measure the heat capacity of five volatile organic compounds. With a deflection noise level of ˜10 nm and a signal-to-noise ratio of 68:1, the BMC offers a sensitivity of 30.5 ms/(J g-1 K-1) and a resolution of 23 mJ/(g K) for ˜150 pl liquid for heat capacity measurements. This technique can be used for small-scale thermal characterization of different chemical and biological samples.
de Paula, M R; Oltramari, C E; Silva, J T; Gallo, M P C; Mourão, G B; Bittar, C M M
2017-06-01
The objective of this study was to evaluate the effects of different liquid-feeding systems using a medium crude protein milk replacer on performance, rumen, and blood parameters. Thirty newborn Holstein calves were blocked according to birth weight and date of birth, and randomly distributed to different liquid-feeding systems: conventional (4 L/d), intensive (8 L/d), or step-up/step-down (wk 1, 4 L/d; wk 2 to 6, 8 L/d; wk 7 and 8, 4 L/d). The commercial milk replacer (12.5% solids, 20.2% crude protein, 15.6% fat) was fed twice daily (0700 and 1700 h) until calves were weaned, at 8 wk of age. Calves were individually housed in wood hutches, with free access to water and starter concentrate, and to hay only after weaning. They were followed through 10 wk of age. Milk replacer and starter intake were inversely affected by feeding system. After weaning, starter intake and hay intake were similar among feeding systems. Total dry matter intake was higher during the liquid-feeding period for calves on the intensive system compared to calves on the conventional system, but conventional feeding resulted in the highest dry matter intake after weaning. Feed efficiency was similar among feeding systems before and after weaning. Average body weight and daily gain were not affected by feeding system before or after weaning. During liquid feeding, diarrhea occurrence was lower for calves on the conventional system; however, when calves on the step-up/step-down system were fed lower volumes of liquid feed, diarrhea occurrence was similar to that of calves on the conventional system. Plasma concentrations of β-hydroxybutyrate were higher for calves on the conventional system, reflecting starter intake. Rumen pH, short-chain fatty acids, and N-NH 3 were not affected by feeding system. Feeding higher volumes of milk replacer with a medium crude protein content had no beneficial effect on the performance of calves up to 10 wk of age. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Effect of Yifukang oral liquid on gastric emptying and intestinal peristalsis in mice
NASA Astrophysics Data System (ADS)
Sun, Jianhua; Li, Jun; Li, Xianyu; Hao, Shaojun; Guo, Junyi; Ma, Zhenzhen; Zhang, Zhengchen
2018-04-01
To observe the effect of Yifukang oral liquid on gastric emptying and intestinal peristalsis in mice. Methods: 60 mice were randomly divided into 5 groups. The suspension of Baohe Pill and the same volume of normal saline group were given once a day for 7 days. After the last administration for 30 minutes, 0.25 ml of 0.04% phenolic red solution was administered by stomach. After 20 minutes, the animals were killed, the stomach was removed, the gastric contents were cleaned, and the lotion 5ml was centrifuged. The absorbance of the supernatant was measured by TU-1901 ultraviolet spectrophotometer at the wavelength of 560nm. The residual rate of gastric phenolic red was calculated. Rate was used to evaluate gastric emptying velocity.60 mice were randomly divided into five groups: group 5, large, medium, small Yifukang oral liquid dosage group, pill suspension and the same volume normal saline. After 20 min after the last dose of carbon powder suspension, the mice were sacrificed, the abdominal cavity was cut open, the intestine of the ileocecum was cut off, the intestinal mesentery was separated, the total length of the small intestine (cm) was measured, and the distance (cm) in the small intestine was measured, and the end-of-carbon propulsion rate was calculated. Compared with the blank group, small dose of Yi Fu Kang group and Baohe Pill group could significantly promote the ability of gastric emptying in mice. Compared with the blank group, small dose group and rehabilitation benefits Baohewan group can significantly promote the gastric emptying ability of mice (P<0.01), high dose group had no obvious benefit rehabilitation ability to promote gastric emptying in mice. Yi Fu Kang oral liquid group could significantly increase the percentage of small intestine carbon powder(P<0.01), Large, medium-dose Yifukang oral liquid and Baofuwan group could significantly increase the percentage of small intestinal carbon in mice (P<0.05). Yi Fukang oral liquid has the effect of promoting gastric emptying and small intestinal peristalsis.
Behavior of radioactive iodine and technetium in the spray calcination of high-level waste
NASA Astrophysics Data System (ADS)
Knox, C. A.; Farnsworth, R. K.
1981-08-01
The Remote Laboratory-Scale Waste Treatment Facility (RLSWTF) was designed and built as a part of the High-Level Waste Immobilization Program (now the High-Level Waste Process Development Program) at the Pacific Northwest Laboratory. In facility, installed in a radiochemical cell, is described in which installed in a radiochemical cell is described in which small volumes of radioactive liquid wastes can be solidified, the process off gas can be analyzed, and the methods for decontaminating this off gas can be tested. During the spray calcination of commercial high-level liquid waste spiked with Tc-99 and I-131 and 31 wt% loss of I-131 past the sintered-metal filters. These filters and venturi scrubber were very efficient in removing particulates and Tc-99 from the the off-gas stream. Liquid scrubbers were not efficient in removing I-131 as 25% of the total lost went to the building off-gas system. Therefore, solid adsorbents are needed to remove iodine. For all future operations where iodine is present, a silver zeolite adsorber is to be used.
Multi-phase-fluid discrimination with local fibre-optical probes: I. Liquid/liquid flows
NASA Astrophysics Data System (ADS)
Fordham, E. J.; Holmes, A.; Ramos, R. T.; Simonian, S.; Huang, S.-M.; Lenn, C. P.
1999-12-01
We demonstrate the use of a novel design of fibre-optical sensor (or `local probe') for immiscible-fluid discrimination in multi-phase flows. These probes are made from standard silica fibres with plane oblique facets polished at the fibre tip, with various surface treatments, including a crucial one for wettability control. Total internal reflection is used to distinguish drops, bubbles or other regions of fluid in multi-phase flows, on the basis of refractive-index contrast. Such probes have quasi-binary outputs; we demonstrate in this paper their use in distinguishing water from oil (kerosene) in oil/water two-phase flows and compare the results with those obtained from a simple cleaved fibre relying on the (small) difference in Fresnel reflectivity for discrimination. Quantitative accuracy is demonstrated by comparison of profiles, across a pipe diameter, of local, time-averaged volume fractions (`hold-ups'), with pipe-averaged hold-ups determined from a carefully calibrated gradio-manometer in a fully developed region of the flow. Companion papers deal with the sensors used and results achieved in gas/liquid flows and three-phase flows.
Numerical Investigation of Liquid Carryover in T-Junction with Different Diameter Ratios
NASA Astrophysics Data System (ADS)
Pao, William; Sam, Ban; Saieed, Ahmed; Tran, Cong Minh
2018-03-01
In offshore Malaysia, T-junction is installed at the production header as a compact separator to tap produced gas from reservoir as fuel gas for power generation. However, excessive liquid carryover in T-junction presents a serious operational issue because it trips the whole production platform. The primary objective of present study is to numerically investigate the liquid carryover due to formation of slug, subsequently its liquid carryover at different diameter ratio. The analyses were carried out on a model with 0.0254 m (1 inch) diameter horizontal main arm and a vertically upward side arm using Volume of Fluid Method. Three different sides to main arm diameter ratio of 1.0, 0.5 and 0.3 were investigated with different gas and liquid superficial velocities. The results showed that, while the general trend is true that smaller diameter ratio T-junction has lesser liquid take off capacity, it has a very high frequency of low liquid carryover threshold. In other words, under slug flow, smaller diameter ratio T-junction is constantly transporting liquid even though at a lesser volume in comparison to regular T-junction.
Code of Federal Regulations, 2010 CFR
2010-07-01
... products means natural gas liquid products including the following: ethane, propane, butane, pentane... resulting from the removal of natural gas liquids and nonhydrocarbon gases. (3) Of liquefied petroleum products means the volume of natural gas liquids produced from reservoir gas and liquefied at surface...
Code of Federal Regulations, 2014 CFR
2014-07-01
... products means natural gas liquid products including the following: ethane, propane, butane, pentane... resulting from the removal of natural gas liquids and nonhydrocarbon gases. (3) Of liquefied petroleum products mean the volume of natural gas liquids produced from reservoir gas and liquefied at surface...
Code of Federal Regulations, 2013 CFR
2013-07-01
... products means natural gas liquid products including the following: ethane, propane, butane, pentane... resulting from the removal of natural gas liquids and nonhydrocarbon gases. (3) Of liquefied petroleum products mean the volume of natural gas liquids produced from reservoir gas and liquefied at surface...
Code of Federal Regulations, 2012 CFR
2012-07-01
... products means natural gas liquid products including the following: ethane, propane, butane, pentane... resulting from the removal of natural gas liquids and nonhydrocarbon gases. (3) Of liquefied petroleum products mean the volume of natural gas liquids produced from reservoir gas and liquefied at surface...
High-pressure liquid chromatography with direct injection of gas sample.
Astanin, Anton I; Baram, Grigory I
2017-06-09
The conventional method of using liquid chromatography to determine the composition of a gaseous mixture entails dissolving vapors in a suitable solvent, then obtaining a chromatograph of the resulting solution. We studied the direct introduction of a gaseous sample into a C18 reversed-phase column, followed by separation of the components by HPLC with UV detection. Since the chromatography was performed at high pressure, vapors readily dissolved in the eluent and the substances separated in the column as effectively as in liquid samples. Samples were injected into the column in two ways: a) through the valve without a flow stop; b) after stopping the flow and relieving all pressure. We showed that an injectable gas volume could reach 70% of column dead volume. When an injected gaseous sample volume was less than 10% of the column dead volume, the resulting peaks were symmetrical and the column efficiency was high. Copyright © 2017 Elsevier B.V. All rights reserved.
Size-exclusion chromatography using core-shell particles.
Pirok, Bob W J; Breuer, Pascal; Hoppe, Serafine J M; Chitty, Mike; Welch, Emmet; Farkas, Tivadar; van der Wal, Sjoerd; Peters, Ron; Schoenmakers, Peter J
2017-02-24
Size-exclusion chromatography (SEC) is an indispensable technique for the separation of high-molecular-weight analytes and for determining molar-mass distributions. The potential application of SEC as second-dimension separation in comprehensive two-dimensional liquid chromatography demands very short analysis times. Liquid chromatography benefits from the advent of highly efficient core-shell packing materials, but because of the reduced total pore volume these materials have so far not been explored in SEC. The feasibility of using core-shell particles in SEC has been investigated and contemporary core-shell materials were compared with conventional packing materials for SEC. Columns packed with very small core-shell particles showed excellent resolution in specific molar-mass ranges, depending on the pore size. The analysis times were about an order of magnitude shorter than what could be achieved using conventional SEC columns. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, M.H.; Lie, Y.C.
1994-07-01
The densities and viscosities of aqueous mixtures of monoethanolamine (MEA) with N-methyldiethanolamine (MDEA) and MEA with 2-amino-2-methyl-1-propanol (AMP) have been studied at temperatures from 30 to 80 C. For density measurements, four MEA + MDEA (a total of 20 mass %) + H[sub 2]O mixtures and eight MEA + AMP (20 and 30 mass %) + H[sub 2]O mixtures were studied. For viscosity measurements, ten MEA + MDEA + H[sub 2]O mixtures and eight MEA + AMP + H[sub 2]O mixtures were measured. A Redlich-Kister equation of the excess volume was applied to represent the density of the liquid mixtures.more » The equation of Grunberg and Nissan of liquid viscosity was used to correlate the viscosity data. Both density and viscosity calculations show satisfactory results.« less
NASA Technical Reports Server (NTRS)
Greeley, R.; Chyba, C.; Head, J. W.; McCord, T.; McKinnon, W. B.; Pappalardo, R. T.
2004-01-01
Europa is a rocky object of radius 1565 km (slightly smaller than Earth s moon) and has an outer shell of water composition estimated to be of order 100 km thick, the surface of which is frozen. The total volume of water is about 3 x 10(exp 9) cubic kilometers, or twice the amount of water on Earth. Moreover, like its neighbor Io, Europa experiences internal heating generated from tidal flexing during its eccentric orbit around Jupiter. This raises the possibility that some of the water beneath the icy crust is liquid. The proportion of rock to ice, the generation of internal heat, and the possibility of liquid water make Europa unique in the Solar System. In this chapter, we outline the sources of data available for Europa (with a focus on the Galileo mission), review previous and on-going research on its surface geology, discuss the astrobiological potential of Europa, and consider plans for future exploration.
ERIC Educational Resources Information Center
Kiriktas, Halit; Sahin, Mehmet; Eslek, Sinan; Kiriktas, Irem
2018-01-01
This study aims to design a mechanism with which the density of any solid or liquid can be determined without measuring its mass and volume in order to help students comprehend the concept of density more easily. The "solidensimeter" comprises of two scaled and nested glass containers (graduated cylinder or beaker) and sufficient water.…
Measurement Corner: Volume, Temperature and Pressure
ERIC Educational Resources Information Center
Teates, Thomas G.
1977-01-01
Boyle's Law and basic relationships between volume and pressure of a gas at constant temperature are presented. Suggests two laboratory activities for demonstrating the effect of temperature on the volume of a gas or liquid. (CS)
NASA Astrophysics Data System (ADS)
Liu, H.; Liu, L. L.; Li, R.; Li, L.
2015-12-01
Liquid gallium exhibits unusual and unique physical properties. A rich polymorphism and metastable modifications of solid Ga have been discovered and a number of studies of liquid gallium under high pressure conditions were reported. However, some fundamental properties, such as the equation of state (EoS) of Ga melt under extreme conditions remain unclear. To compare to the previous reports, we performed the pair distribution function (PDF) study using diamond anvil cell, in which synchrotron high-energy x-ray total scattering data, combined with reverse Monte Carlo simulation, was used to study the microstructure and EoS of liquid gallium under high pressure at room temperature conditions. The EoS of Ga melt, which was measured from synchrotron x-ray tomography method at room temperature, was used to avoid the potential relatively big errors for the density estimation from the reverse Monte Carlo simulation with the mathematical fit to the measured structure factor data. The volume change of liquid gallium have been studied as a function of pressure and temperature up to 5 GPa at 370 K using synchrotron x-ray microtomography combined with energy dispersive x-ray diffraction (EDXRD) techniques using Drickamer press. The directly measured P-V-T curves were obtained from 3D tomography reconstruction data. The existence of possible liquid-liquid phase transition regions is proposed based on the abnormal compressibility and local structure change in Ga melts.
The use of lithium as a marker for the retention of liquids in the oral cavity after rinsing.
Hanning, Sara M; Kieser, Jules A; Ferguson, Martin M; Reid, Malcolm; Medlicott, Natalie J
2014-01-01
The aim of this study was to validate the use of lithium as a marker to indicate the retention of simple liquids in the oral cavity and use this to determine how much liquid is retained in the oral cavity following 30 s of rinsing. This is a validation study in which saliva was spiked with known concentrations of lithium. Twenty healthy participants then rinsed their mouths with either water or a 1 % w/v carboxymethylcellulose (CMC) solution for 30 s before expectorating into a collection cup. Total volume and concentration of lithium in the expectorant were then measured, and the percentage of liquid retained was calculated. The mean amount of liquid retained was 10.4 ± 4.7 % following rinsing with water and 15.3 ± 4.1 % following rinsing with 1 % w/v CMC solution. This difference was significant (p < 0.01). Lithium was useful as a marker for the retention of liquids in the oral cavity, and a value for the amount of water and 1 % w/v CMC solution remaining in the oral cavity following a 30-s rinse was established. The present study quantifies the retention of simple fluids in the oral cavity, validating a technique that may be applied to more complex fluids such as mouth rinses. Further, the application of this method to specific population groups such as those with severe xerostomia may assist in developing effective saliva substitutes.
Change of hydrogen bonding structure in ionic liquid mixtures by anion type
NASA Astrophysics Data System (ADS)
Cha, Seoncheol; Kim, Doseok
2018-05-01
Ionic liquid mixtures have gained attention as a way of tuning material properties continuously with composition changes. For some mixture systems, physicochemical properties such as excess molar volume have been found to be significantly different from the value expected by linear interpolation, but the origin of this deviation is not well understood yet. The microstructure of the mixture, which can range from an ideal mixture of two initial consisting ionic liquids to a different structure from those of pure materials, has been suggested as the origin of the observed deviation. The structures of several different ionic liquid mixtures are studied by IR spectroscopy to confirm this suggestion, as a particular IR absorption band (νC(2)-D) for the moiety participating in the hydrogen bonding changes sensitively with the change of the anion in the ionic liquid. The absorbance of νC(2)-D changes proportionally with the composition, and a relatively small excess molar volume is observed for the mixtures containing an electronegative halide anion. By contrast, the absorbance changes nonlinearly, and the excess molar volumes are larger for the mixtures of which one of the anions has multiple interaction sites.
Drops spreading on flexible fibers
NASA Astrophysics Data System (ADS)
Somszor, Katarzyna; Boulogne, François; Sauret, Alban; Dressaire, Emilie; Stone, Howard
2015-11-01
Fibrous media are encountered in many engineered systems such as textile, paper and insulating materials. In most of these materials, fibers are randomly oriented and form a complex network in which drops of wetting liquid tend to accumulate at the nodes of the network. Here we investigate the role of the fiber flexibility on the spreading of a small volume of liquid on a pair of crossed flexible fibers. A drop of silicone oil is dispensed at the point of contact of the fibers and we characterize the liquid morphologies as we vary the volume of liquid, the angle between the fibers, and the length and bending modulus of the fibers. Drop morphologies previously reported for rigid fibers, i.e. a drop, a column and a mixed morphology, are also observed on flexible fibers with modified domains of existence. Moreover, at small inclination angles of the fibers, a new behavior is observed: the fibers bend and collapse. Depending on the volume, the liquid can adopt a column or a mixed morphology on the collapsed fibers. We rationalize our observations with a model based on energetic considerations. Our study suggests that the fiber flexibility adds a rich variety of behaviors that can be crucial for industrial applications.
Phospholipid component volumes: determination and application to bilayer structure calculations.
Armen, R S; Uitto, O D; Feller, S E
1998-08-01
We present a new method for the determination of bilayer structure based on a combination of computational studies and laboratory experiments. From molecular dynamics simulations, the volumes of submolecular fragments of saturated and unsaturated phosphatidylcholines in the liquid crystalline state have been extracted with a precision not available experimentally. Constancy of component volumes, both among different lipids and as a function of membrane position for a given lipid, have been examined. The component volumes were then incorporated into the liquid crystallographic method described by Wiener and White (1992. Biophys. J. 61:434-447, and references therein) for determining the structure of a fluid-phase dioleoylphosphatidylcholine bilayer from x-ray and neutron diffraction experiments.
Phospholipid component volumes: determination and application to bilayer structure calculations.
Armen, R S; Uitto, O D; Feller, S E
1998-01-01
We present a new method for the determination of bilayer structure based on a combination of computational studies and laboratory experiments. From molecular dynamics simulations, the volumes of submolecular fragments of saturated and unsaturated phosphatidylcholines in the liquid crystalline state have been extracted with a precision not available experimentally. Constancy of component volumes, both among different lipids and as a function of membrane position for a given lipid, have been examined. The component volumes were then incorporated into the liquid crystallographic method described by Wiener and White (1992. Biophys. J. 61:434-447, and references therein) for determining the structure of a fluid-phase dioleoylphosphatidylcholine bilayer from x-ray and neutron diffraction experiments. PMID:9675175
Luis, Patricia; Wouters, Christine; Van der Bruggen, Bart; Sandler, Stanley I
2013-08-09
Head-space gas chromatography (HS-GC) is an applicable method to perform vapor-liquid equilibrium measurements and determine activity coefficients. However, the reproducibility of the data may be conditioned by the experimental procedure concerning to the automated pressure-balanced system. The study developed in this work shows that a minimum volume of liquid in the vial is necessary to ensure the reliability of the activity coefficients since it may become a parameter that influences the magnitude of the peak areas: the helium introduced during the pressurization step may produce significant variations of the results when too small volume of liquid is selected. The minimum volume required should thus be evaluated prior to obtain experimentally the concentration in the vapor phase and the activity coefficients. In this work, the mixture acetonitrile-toluene is taken as example, requiring a sample volume of more than 5mL (about more than 25% of the vial volume). The vapor-liquid equilibrium and activity coefficients of mixtures at different concentrations (0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9 molar fraction) and four temperatures (35, 45, 55 and 70°C) have been determined. Relative standard deviations (RSD) lower than 5% have been obtained, indicating the good reproducibility of the method when a sample volume larger than 5mL is used. Finally, a general procedure to measure activity coefficients by means of pressure-balanced head-space gas chromatography is proposed. Copyright © 2013 Elsevier B.V. All rights reserved.
Lipin, Bruce R.
1993-01-01
This paper explores the hypothesis that chromite seams in the Stillwater Complex formed in response to periodic increases in total pressure in the chamber. Total pressure increased because of the positive δV of nucleation of CO2 bubbles in the melt and their subsequent rise through the magma chamber, during which the bubbles increased in volume by a factor of 4–6. By analogy with the pressure changes in the summit chambers of Kilauea and Krafla volcanoes, the maximum variation was 0⋅2–0⋅25 kbar, or 5–10% of the total pressure in the Stillwater chamber. An evaluation of the likelihood of fountaining and mixing of a new, primitive liquid that entered the chamber with the somewhat more evolved liquid already in the chamber is based upon calculations using observed and inferred velocities and flow rates of basaltic magmas moving through volcanic fissures. The calculations indicate that hot, dense magma would have oozed, rather than fountained into the chamber, and early mixing of the new and residual magmas that could have resulted in chromite crystallizing alone did not take place.Mixing was an important process in the Stillwater magma chamber, however. After the new magma in the chamber underwent ˜5% fractional crystallization, its composition, temperature, and density approached those of the overlying liquid in the chamber and the liquids then mixed. If this process occurred many times over the course of the development of the Ultramafic series, a thick column of magma with orthopyroxene on its liquidus would have been the result. Thus, the sequence of multiple injections, fractionation, and mixing with previously fractionated magma could have been the mechanism that produced the thick bronzite cumulate layer (the Bronzitite zone) above the cyclic units.
NASA Technical Reports Server (NTRS)
Bhandari, Pradeep; Dudik, Brenda; Birur, Gajanana; Karlmann, Paul; Bame, David; Mastropietro, A. J.
2012-01-01
For single phase mechanically pumped fluid loops used for thermal control of spacecraft, a gas charged accumulator is typically used to modulate pressures within the loop. This is needed to accommodate changes in the working fluid volume due to changes in the operating temperatures as the spacecraft encounters varying thermal environments during its mission. Overall, the three key requirements on the accumulator to maintain an appropriate pressure range throughout the mission are: accommodation of the volume change of the fluid due to temperature changes, avoidance of pump cavitation and prevention of boiling in the liquid. The sizing and design of such an accumulator requires very careful and accurate accounting of temperature distribution within each element of the working fluid for the entire range of conditions expected, accurate knowledge of volume of each fluid element, assessment of corresponding pressures needed to avoid boiling in the liquid, as well as the pressures needed to avoid cavitation in the pump. The appropriate liquid and accumulator strokes required to accommodate the liquid volume change, as well as the appropriate gas volumes, require proper sizing to ensure that the correct pressure range is maintained during the mission. Additionally, a very careful assessment of the process for charging both the gas side and the liquid side of the accumulator is required to properly position the bellows and pressurize the system to a level commensurate with requirements. To achieve the accurate sizing of the accumulator and the charging of the system, sophisticated EXCEL based spreadsheets were developed to rapidly come up with an accumulator design and the corresponding charging parameters. These spreadsheets have proven to be computationally fast and accurate tools for this purpose. This paper will describe the entire process of designing and charging the system, using a case study of the Mars Science Laboratory (MSL) fluid loops, which is en route to Mars for an August 2012 landing.
Piezo- and solenoid valve-based liquid dispensing for miniaturized assays.
Niles, Walter D; Coassin, Peter J
2005-04-01
Miniaturization of biological assays requires dispensing liquids in the submicroliter range of volumes. Accuracy and reproducibility of dispensing this range depend on both the dispenser and the receptacle in which the assay is constructed. Miniaturization technologies developed by Aurora Discovery, Inc. (San Diego, CA) include high-density multiwell plates for assay samples and reagent storage, as well as piezo-based and solenoid valve-based liquid dispensers. Some basic principles of small-volume dispensing by jetting are described to provide context for dispenser design and function. Performance of the latest instruments incorporating these dispensing devices is presented.
Regulation of human airway surface liquid.
Widdicombe, J H; Widdicombe, J G
1995-01-01
Human airways are lined with a film of liquid from 5-100 microns in depth, consisting of a periciliary sol around and a mucous gel above the cilia. Microscopical studies have shown the sol to be invariably the same depth as the length of the cilia, and we discuss possible reasons for this. The composition and sources of the airway surface liquid are also described. In addition the forces regulating its volume are analyzed. Several airway diseases are characterised by dramatic changes in the volume and composition of airway liquid. We review recent research suggesting that the accumulation of airway mucous secretions in cystic fibrosis is caused by alterations in active transport of ions and water across both the surface and gland epithelia.
Plasma Reforming of Liquid Hydrocarbon Fuels in Non-Thermal Plasma-Liquid Systems
2010-04-30
microporous liquid which has a very large ratio of the plasma-liquid contact surface to the plasma volume. As is known the ultrasonic (US) cavitation is a very...effective method for creating micropores in liquid [17]. Therefore, the DGCLW with additional US pumping is also very interesting for research and...electrodes. Another PLS reactor was prepared with the DGCLW working with the air flow in the liquid under the induced microporous
Itopride for gastric volume, gastric emptying and drinking capacity in functional dyspepsia
Abid, Shahab; Jafri, Wasim; Zaman, Maseeh Uz; Bilal, Rakhshanda; Awan, Safia; Abbas, Aamir
2017-01-01
AIM To study the effect of itopride on gastric accommodation, gastric emptying and drinking capacity in functional dyspepsia (FD). METHODS Randomized controlled trial was conducted to check the effect of itopride on gastric accommodation, gastric emptying, capacity of tolerating nutrient liquid and symptoms of FD. We recruited a total of 31 patients having FD on the basis of ROME III criteria. After randomization, itopride was received by 15 patients while 16 patients received placebo. Gastric accommodation was determined using Gastric Scintigraphy. 13C labeled octanoic breadth test was performed to assess gastric emptying. Capacity of tolerating nutrient liquid drink was checked using satiety drinking capacity test. The intervention group comprised of 150 mg itopride. Patients in both arms were followed for 4 wk. RESULTS Mean age of the recruited participant 33 years (SD = 7.6) and most of the recruited individuals, i.e., 21 (67.7%) were males. We found that there was no effect of itopride on gastric accommodation as measured at different in volumes in the itopride and control group with the empty stomach (P = 0.14), at 20 min (P = 0.38), 30 min (P = 0.30), 40 min (P = 0.43), 50 min (P = 0.50), 60 min (P = 0.81), 90 min (P = 0.25) and 120 min (P = 0.67). Gastric emptying done on a sub sample (n = 11) showed no significant difference (P = 0.58) between itopride and placebo group. There was no significant improvement in the capacity to tolerate liquid in the itopride group as compared to placebo (P = 0.51). Similarly there was no significant improvement of symptoms as assessed through a composite symptom score (P = 0.74). The change in QT interval in itopride group was not significantly different from placebo (0.10). CONCLUSION Our study found no effect of itopride on gastric accommodation, gastric emptying and maximum tolerated volume in patients with FD. PMID:28217377
Itopride for gastric volume, gastric emptying and drinking capacity in functional dyspepsia.
Abid, Shahab; Jafri, Wasim; Zaman, Maseeh Uz; Bilal, Rakhshanda; Awan, Safia; Abbas, Aamir
2017-02-06
To study the effect of itopride on gastric accommodation, gastric emptying and drinking capacity in functional dyspepsia (FD). Randomized controlled trial was conducted to check the effect of itopride on gastric accommodation, gastric emptying, capacity of tolerating nutrient liquid and symptoms of FD. We recruited a total of 31 patients having FD on the basis of ROME III criteria. After randomization, itopride was received by 15 patients while 16 patients received placebo. Gastric accommodation was determined using Gastric Scintigraphy. 13 C labeled octanoic breadth test was performed to assess gastric emptying. Capacity of tolerating nutrient liquid drink was checked using satiety drinking capacity test. The intervention group comprised of 150 mg itopride. Patients in both arms were followed for 4 wk. Mean age of the recruited participant 33 years (SD = 7.6) and most of the recruited individuals, i.e ., 21 (67.7%) were males. We found that there was no effect of itopride on gastric accommodation as measured at different in volumes in the itopride and control group with the empty stomach ( P = 0.14), at 20 min ( P = 0.38), 30 min ( P = 0.30), 40 min ( P = 0.43), 50 min ( P = 0.50), 60 min ( P = 0.81), 90 min ( P = 0.25) and 120 min ( P = 0.67). Gastric emptying done on a sub sample ( n = 11) showed no significant difference ( P = 0.58) between itopride and placebo group. There was no significant improvement in the capacity to tolerate liquid in the itopride group as compared to placebo ( P = 0.51). Similarly there was no significant improvement of symptoms as assessed through a composite symptom score ( P = 0.74). The change in QT interval in itopride group was not significantly different from placebo (0.10). Our study found no effect of itopride on gastric accommodation, gastric emptying and maximum tolerated volume in patients with FD.
Nasrabad, Afshin Eskandari; Laghaei, Rozita; Eu, Byung Chan
2005-04-28
In previous work on the density fluctuation theory of transport coefficients of liquids, it was necessary to use empirical self-diffusion coefficients to calculate the transport coefficients (e.g., shear viscosity of carbon dioxide). In this work, the necessity of empirical input of the self-diffusion coefficients in the calculation of shear viscosity is removed, and the theory is thus made a self-contained molecular theory of transport coefficients of liquids, albeit it contains an empirical parameter in the subcritical regime. The required self-diffusion coefficients of liquid carbon dioxide are calculated by using the modified free volume theory for which the generic van der Waals equation of state and Monte Carlo simulations are combined to accurately compute the mean free volume by means of statistical mechanics. They have been computed as a function of density along four different isotherms and isobars. A Lennard-Jones site-site interaction potential was used to model the molecular carbon dioxide interaction. The density and temperature dependence of the theoretical self-diffusion coefficients are shown to be in excellent agreement with experimental data when the minimum critical free volume is identified with the molecular volume. The self-diffusion coefficients thus computed are then used to compute the density and temperature dependence of the shear viscosity of liquid carbon dioxide by employing the density fluctuation theory formula for shear viscosity as reported in an earlier paper (J. Chem. Phys. 2000, 112, 7118). The theoretical shear viscosity is shown to be robust and yields excellent density and temperature dependence for carbon dioxide. The pair correlation function appearing in the theory has been computed by Monte Carlo simulations.
Cuomo, Rosario; Savarese, Maria Flavia; Sarnelli, Giovanni; Nicolai, Emanuele; Aragri, Adriana; Cirillo, Carla; Vozzella, Letizia; Zito, Francesco Paolo; Verlezza, Viviana; Efficie, Eleonora; Buyckx, Maxime
2011-10-14
There is conflicting data on the effects of carbon dioxide contained in beverages on stomach functions. We aimed to verify the effect of a pre-meal administration of a 300 ml non-caloric carbonated beverage (B+CO2) compared to water or a beverage without CO2 (B-CO2), during a solid (SM) and a liquid meal (LM) on: a) gastric volume, b) caloric intake, c) ghrelin and cholecystokinin (CCK) release in healthy subjects. After drinking the beverages (Water, B-CO2, B+CO2), ten healthy subjects (4 women, aged 22-30 years; BMI 23 ± 1) were asked to consume either an SM or an LM, at a constant rate (110 kcal/5 min). Total gastric volumes (TGV) were evaluated by Magnetic Resonance Imaging after drinking the beverage and at maximum satiety (MS). Total kcal intake at MS was evaluated. Ghrelin and CCK were measured by enzyme immunoassay until 120 min after the meal. Statistical calculations were carried out by paired T-test and analysis of variance (ANOVA). The data is expressed as mean ± SEM. TGV after B+CO2 consumption was significantly higher than after B-CO2 or water (p < 0.05), but at MS, it was no different either during the SM or the LM. Total kcal intake did not differ at MS after any of the beverages tested, with either the SM (Water: 783 ± 77 kcals; B-CO2: 837 ± 66; B+CO2: 774 ± 66) or the LM (630 ± 111; 585 ± 88; 588 ± 95). Area under curve of ghrelin was significantly (p < 0.05) lower (13.8 ± 3.3 ng/ml/min) during SM following B-CO2 compared to B+CO2 and water (26.2 ± 4.5; 27.1 ± 5.1). No significant differences were found for ghrelin during LM, and for CCK during both SM and LM after all beverages. The increase in gastric volume following a 300 ml pre-meal carbonated beverage did not affect food intake whether a solid or liquid meal was given. The consistency of the meal and the carbonated beverage seemed to influence ghrelin release, but were unable, under our experimental conditions, to modify food intake in terms of quantity. Further studies are needed to verify if other food and beverage combinations are able to modify satiation.
2011-01-01
Background There is conflicting data on the effects of carbon dioxide contained in beverages on stomach functions. We aimed to verify the effect of a pre-meal administration of a 300 ml non-caloric carbonated beverage (B+CO2) compared to water or a beverage without CO2 (B-CO2), during a solid (SM) and a liquid meal (LM) on: a) gastric volume, b) caloric intake, c) ghrelin and cholecystokinin (CCK) release in healthy subjects. Methods After drinking the beverages (Water, B-CO2, B+CO2), ten healthy subjects (4 women, aged 22-30 years; BMI 23 ± 1) were asked to consume either an SM or an LM, at a constant rate (110 kcal/5 min). Total gastric volumes (TGV) were evaluated by Magnetic Resonance Imaging after drinking the beverage and at maximum satiety (MS). Total kcal intake at MS was evaluated. Ghrelin and CCK were measured by enzyme immunoassay until 120 min after the meal. Statistical calculations were carried out by paired T-test and analysis of variance (ANOVA). The data is expressed as mean ± SEM. Results TGV after B+CO2 consumption was significantly higher than after B-CO2 or water (p < 0.05), but at MS, it was no different either during the SM or the LM. Total kcal intake did not differ at MS after any of the beverages tested, with either the SM (Water: 783 ± 77 kcals; B-CO2: 837 ± 66; B+CO2: 774 ± 66) or the LM (630 ± 111; 585 ± 88; 588 ± 95). Area under curve of ghrelin was significantly (p < 0.05) lower (13.8 ± 3.3 ng/ml/min) during SM following B-CO2 compared to B+CO2 and water (26.2 ± 4.5; 27.1 ± 5.1). No significant differences were found for ghrelin during LM, and for CCK during both SM and LM after all beverages. Conclusions The increase in gastric volume following a 300 ml pre-meal carbonated beverage did not affect food intake whether a solid or liquid meal was given. The consistency of the meal and the carbonated beverage seemed to influence ghrelin release, but were unable, under our experimental conditions, to modify food intake in terms of quantity. Further studies are needed to verify if other food and beverage combinations are able to modify satiation. PMID:21999723
Liu, Zhongling; Yu, Wei; Zhang, Hanqi; Gu, Fanbin; Jin, Xiangqun
2016-12-01
Salting-out homogenous extraction followed by ionic liquid/ionic liquid dispersive liquid-liquid micro-extraction system was developed and applied to the extraction of sulfonamides in blood. High-performance liquid chromatography was applied to the determination of the analytes. The blood sample was centrifuged to obtain the serum. After the proteins in the serum were removed in the presence of acetonitrile, ionic liquid 1-butyl-3-methylimidazolium tetrafluoroborate, dipotassium hydrogen phosphate, ionic liquid 1-Hexyl-3-methylimidazolium hexafluorophosphate were added into the resulting solution. After the resulting mixture was ultrasonically shaken and centrifuged, the precipitate was separated. The acetonitrile was added in the precipitate and the analytes were extracted into the acetonitrile phase. The parameters affecting the extraction efficiency, such as volume of ionic liquid, amount of dipotassium hydrogen phosphate, volume of dispersant, extraction time and temperature were investigated. The limits of detection of sulfamethizole (STZ), sulfachlorpyridazine (SCP), sulfamethoxazole (SMX) and Sulfisoxazole (SSZ) were 4.78, 3.99, 5.21 and 3.77μgL -1 , respectively. When the present method was applied to the analysis of real blood samples, the recoveries of analytes ranged from 90.0% to 113.0% and relative standard deviations were lower than 7.2%. Copyright © 2016 Elsevier B.V. All rights reserved.
Refractive index of liquid mixtures: theory and experiment.
Reis, João Carlos R; Lampreia, Isabel M S; Santos, Angela F S; Moita, Maria Luísa C J; Douhéret, Gérard
2010-12-03
An innovative approach is presented to interpret the refractive index of binary liquid mixtures. The concept of refractive index "before mixing" is introduced and shown to be given by the volume-fraction mixing rule of the pure-component refractive indices (Arago-Biot formula). The refractive index of thermodynamically ideal liquid mixtures is demonstrated to be given by the volume-fraction mixing rule of the pure-component squared refractive indices (Newton formula). This theoretical formulation entails a positive change of refractive index upon ideal mixing, which is interpreted in terms of dissimilar London dispersion forces centred in the dissimilar molecules making up the mixture. For real liquid mixtures, the refractive index of mixing and the excess refractive index are introduced in a thermodynamic manner. Examples of mixtures are cited for which excess refractive indices and excess molar volumes show all of the four possible sign combinations, a fact that jeopardises the finding of a general equation linking these two excess properties. Refractive indices of 69 mixtures of water with the amphiphile (R,S)-1-propoxypropan-2-ol are reported at five temperatures in the range 283-303 K. The ideal and real refractive properties of this binary system are discussed. Pear-shaped plots of excess refractive indices against excess molar volumes show that extreme positive values of excess refractive index occur at a substantially lower mole fraction of the amphiphile than extreme negative values of excess molar volume. Analysis of these plots provides insights into the mixing schemes that occur in different composition segments. A nearly linear variation is found when Balankina's ratios between excess and ideal values of refractive indices are plotted against ratios between excess and ideal values of molar volumes. It is concluded that, when coupled with volumetric properties, the new thermodynamic functions defined for the analysis of refractive indices of liquid mixtures give important complementary information on the mixing process over the whole composition range.
Eoff, Jennifer D.; Biewick, Laura R.H.; Brownfield, Michael E.; Burke, Lauri; Charpentier, Ronald R.; Dubiel, Russell F.; Gaswirth, Stephanie B.; Gianoutsos, Nicholas J.; Kinney, Scott A.; Klett, Timothy R.; Leathers, Heidi M.; Mercier, Tracey J.; Paxton, Stanley T.; Pearson, Ofori N.; Pitman, Janet K.; Schenk, Christopher J.; Tennyson, Marilyn E.; Whidden, Katherine J.
2015-08-11
Using a geology-based assessment methodology, the U.S. Geological Survey estimated undiscovered mean volumes of 14 million barrels of conventional oil, 430 billion cubic feet of conventional gas, 34,028 billion cubic feet of continuous gas, and a mean total of 391 million barrels of natural gas liquids in sandstone reservoirs of the Upper Jurassic–Lower Cretaceous Cotton Valley Group in onshore lands and State waters of the U.S. Gulf Coast region.
Falabella, Steven; Meyer, Glenn A; Tang, Vincent; Guethlein, Gary
2014-06-10
A two-phase mixed media insulator having a dielectric fluid filling the interstices between macro-sized dielectric beads packed into a confined volume, so that the packed dielectric beads inhibit electro-hydrodynamically driven current flows of the dielectric liquid and thereby increase the resistivity and breakdown strength of the two-phase insulator over the dielectric liquid alone. In addition, an electrical apparatus incorporates the two-phase mixed media insulator to insulate between electrical components of different electrical potentials. And a method of electrically insulating between electrical components of different electrical potentials fills a confined volume between the electrical components with the two-phase dielectric composite, so that the macro dielectric beads are packed in the confined volume and interstices formed between the macro dielectric beads are filled with the dielectric liquid.
Wolfson, Marla R; Hirschl, Ronald B; Jackson, J Craig; Gauvin, France; Foley, David S; Lamm, Wayne J E; Gaughan, John; Shaffer, Thomas H
2008-01-01
We performed a multicenter study to test the hypothesis that tidal liquid ventilation (TLV) would improve cardiopulmonary, lung histomorphological, and inflammatory profiles compared with conventional mechanical gas ventilation (CMV). Sheep were studied using the same volume-controlled, pressure-limited ventilator systems, protocols, and treatment strategies in three independent laboratories. Following baseline measurements, oleic acid lung injury was induced and animals were randomized to 4 hours of CMV or TLV targeted to "best PaO2" and PaCO2 35 to 60 mm Hg. The following were significantly higher (p < 0.01) during TLV than CMV: PaO2, venous oxygen saturation, respiratory compliance, cardiac output, stroke volume, oxygen delivery, ventilatory efficiency index; alveolar area, lung % gas exchange space, and expansion index. The following were lower (p < 0.01) during TLV compared with CMV: inspiratory and expiratory pause pressures, mean airway pressure, minute ventilation, physiologic shunt, plasma lactate, lung interleukin-6, interleukin-8, myeloperoxidase, and composite total injury score. No significant laboratories by treatment group interactions were found. In summary, TLV resulted in improved cardiopulmonary physiology at lower ventilatory requirements with more favorable histological and inflammatory profiles than CMV. As such, TLV offers a feasible ventilatory alternative as a lung protective strategy in this model of acute lung injury.
Drop size distributions and related properties of fog for five locations measured from aircraft
NASA Technical Reports Server (NTRS)
Zak, J. Allen
1994-01-01
Fog drop size distributions were collected from aircraft as part of the Synthetic Vision Technology Demonstration Program. Three west coast marine advection fogs, one frontal fog, and a radiation fog were sampled from the top of the cloud to the bottom as the aircraft descended on a 3-degree glideslope. Drop size versus altitude versus concentration are shown in three dimensional plots for each 10-meter altitude interval from 1-minute samples. Also shown are median volume radius and liquid water content. Advection fogs contained the largest drops with median volume radius of 5-8 micrometers, although the drop sizes in the radiation fog were also large just above the runway surface. Liquid water content increased with height, and the total number of drops generally increased with time. Multimodal variations in number density and particle size were noted in most samples where there was a peak concentration of small drops (2-5 micrometers) at low altitudes, midaltitude peak of drops 5-11 micrometers, and high-altitude peak of the larger drops (11-15 micrometers and above). These observations are compared with others and corroborate previous results in fog gross properties, although there is considerable variation with time and altitude even in the same type of fog.
Okwuosa, Tochukwu C; Soares, Cindy; Gollwitzer, Verena; Habashy, Rober; Timmins, Peter; Alhnan, Mohamed A
2018-06-15
A method for the production of liquid capsules with the potential of modifying drug dose and release is presented. For the first time, the co-ordinated use of fused deposition modelling (FDM), 3D printing and liquid dispensing to fabricate individualised dosage form on demand in a fully automated fashion has been demonstrated. Polymethacrylate shells (Eudragit EPO and RL) for immediate and extended release were fabricated using FDM 3D printing and simultaneously filled using a computer-controlled liquid dispenser loaded with model drug solution (theophylline) or suspension (dipyridamole). The impact of printing modes: simultaneous shell printing and filling (single-phase) or sequential 3D printing of shell bottom, filling and shell cap (multi-phase), nozzle size, syringe volume, and shell structure has been reported. The use of shell thickness of 1.6 mm, and concentric architecture allowed successful containment of liquid core whilst maintaining the release properties of the 3D printed liquid capsule. The linear relationship between the theoretical and the actual volumes from the dispenser reflected its potential for accurate dosing (R 2 = 0.9985). Modifying the shell thickness of Eudragit RL capsule allowed a controlled extended drug release without the need for formulation change. Owing to its low cost and versatility, this approach can be adapted to wide spectrum of liquid formulations such as small and large molecule solutions and obviate the need for compatibility with the high temperature of FDM 3D printing process. In a clinical setting, health care staff will be able to instantly manufacture in small volumes liquid capsules with individualised dose contents and release pattern in response to specific patient's needs. Copyright © 2018 Elsevier B.V. All rights reserved.
Cavities in molecular liquids and the theory of hydrophobic solubilities
NASA Technical Reports Server (NTRS)
Pohorille, A.; Pratt, L. R.; MacElroy, R. (Principal Investigator)
1990-01-01
Thermal configurational data on neat liquids are used to obtain the work of formation of hard spherical cavities of atomic size in six molecular solvents: n-hexane, n-dodecane, n-undecyl alcohol, chloroform, carbon tetrachloride, and water. These results are used to test a recent suggestion that the differences between nonaqueous solvents and liquid water in solvation of inert gases are not principally due to the hydrogen-bonded structure of liquid water but rather to the comparatively small size of the water molecule. The frequencies of occurrence of cavities in liquid water can be meaningfully distinguished from those in the organic solvents. Liquid water has a larger fractional free volume, but that free volume is distributed in smaller packets. With respect to cavity work, water is compared to a solvent of the same molecular density and composed of hard spheres of the same size as the water molecule. That comparison indicates that the hard-sphere liquid finds more ways to configure its free volume in order to accommodate an atomic solute of substantial size and thus, would be more favorable solvent for inert gases. The scaled particle model of inert gas solubility in liquid water predicts cavity works 20% below the numerical data for TIP4P water at 300 K and 1.0 g/cm3 for cavity radii near 2.0 angstroms. It is argued that the sign of this difference is just the sign that ought to be expected and that the magnitude of this difference measures structural differences between water and the directly comparable hard-sphere liquid. In conjunction with previous data, these results indicate that atomic sized cavities should be considered submacroscopic.
Gauging Systems Monitor Cryogenic Liquids
NASA Technical Reports Server (NTRS)
2009-01-01
Rocket fuel needs to stay cool - super cool, in fact. The ability to store gas propellants like liquid hydrogen and oxygen at cryogenic temperatures (below -243 F) is crucial for space missions in order to reduce their volumes and allow their storage in smaller (and therefore, less costly) tanks. The Agency has used these cryogenic fluids for vehicle propellants, reactants, and life support systems since 1962 with the Centaur upper stage rocket, which was powered with liquid oxygen and liquid hydrogen. During proposed long-duration missions, super-cooled fluids will also be used in space power systems, spaceports, and lunar habitation systems. In the next generation of launch vehicles, gaseous propellants will be cooled to and stored for extended periods at even colder temperatures than currently employed via a process called densification. Densification sub-cools liquids to temperatures even closer to absolute zero (-459 F), increasing the fluid s density and shrinking its volume beyond common cryogenics. Sub-cooling cryogenic liquid hydrogen, for instance, from 20 K (-423 F) to 15 K (-432.4 F) reduces its mass by 10 percent. These densified liquid gases can provide more cost savings from reduced payload volume. In order to benefit from this cost savings, the Agency is working with private industry to prevent evaporation, leakage, and other inadvertent loss of liquids and gases in payloads - requiring new cryogenic systems to prevent 98 percent (or more) of boil-off loss. Boil-off occurs when cryogenic or densified liquids evaporate, and is a concern during launch pad holds. Accurate sensing of propellants aboard space vehicles is also critical for proper engine shutdown and re-ignition after launch, and zero boil-off fuel systems are also in development for the Altair lunar lander.
Electrowetting-actuated optical switch based on total internal reflection.
Liu, Chao; Wang, Di; Yao, Li-Xiao; Li, Lei; Wang, Qiong-Hua
2015-04-01
In this paper we demonstrate a liquid optical switch based on total internal reflection. Two indium tin oxide electrodes are fabricated on the bottom substrate. A conductive liquid (Liquid 1) is placed on one side of the chamber and surrounded by a density-matched silicone oil (Liquid 2). In initial state, when the light beam illuminates the interface of the two liquids, it just meets the conditions of total internal reflection. The light is totally reflected by Liquid 2, and the device shows light-off state. When we apply a voltage to the other side of the indium tin oxide electrode, Liquid 1 stretched towards this side of the substrate and the curvature of the liquid-liquid interface changes. The light beam is refracted by Liquid 1 and the device shows light-on state. So the device can achieve the functions of an optical switch. Because the light beam can be totally reflected by the liquid, the device can attain 100% light intensity attenuation. Our experiments show that the response time from light-on (off) to light-off (on) are 130 and 132 ms, respectively. The proposed optical switch has potential applications in variable optical attenuators, information displays, and light shutters.
Estimation of liquid volume fraction using ultrasound transit time spectroscopy
NASA Astrophysics Data System (ADS)
Al-Qahtani, Saeed M.; Langton, Christian M.
2016-12-01
It has recently been proposed that the propagation of an ultrasound wave through complex structures, consisting of two-materials of differing ultrasound velocity, may be considered as an array of parallel ‘sonic rays’, the transit time of each determined by their relative proportion; being a minimum (t min) in entire higher velocity material, and a maximum (t max) in entire lower velocity material. An ultrasound transit time spectrum (UTTS) describes the proportion of sonic rays at an individual transit time. It has previously been demonstrated that the solid volume fraction of a solid:liquid composite, specifically acrylic step-wedges immersed in water, may be reliably estimated from the UTTS. The aim of this research was to investigate the hypothesis that the volume fraction of a two-component liquid mixture, of unequal ultrasound velocity, may also be estimated by UTTS. A through-transmission technique incorporating two 1 MHz ultrasound transducers within a horizontally-aligned cylindrical tube-housing was utilised, the proportion of silicone oil to water being varied from 0% to 100%. The liquid volume fraction was estimated from the UTTS at each composition, the coefficient of determination (R 2%) being 98.9 ± 0.7%. The analysis incorporated a novel signal amplitude normalisation technique to compensate for absorption within the silicone oil. It is therefore envisaged that the parallel sonic ray concept and the derived UTTS may be further applied to the quantification of liquid mixture composition assessment.
Zhou, Caihong; Tong, Shanshan; Chang, Yunxia; Jia, Qiong; Zhou, Weihong
2012-04-01
Ionic liquid (IL) based dispersive liquid-liquid microextraction (DLLME) with back-extraction coupled with capillary electrophoresis ultraviolet detection was developed to determine four phenolic compounds (bisphenol-A, β-naphthol, α-naphthol, 2, 4-dichlorophenol) in aqueous cosmetics. The developed method was used to preconcentrate and clean up the four phenolic compounds including two steps. The analytes were transferred into room temperature ionic liquid (1-octyl-3-methylimidazolium hexafluorophosphate, [C(8) MIM][PF(6) ]) rich-phase in the first step. In the second step, the analytes were back-extracted into the alkaline aqueous phase. The effects of extraction parameters, such as type and volume of extraction solvent, type and volume of disperser, extraction and centrifugal time, sample pH, salt addition, and concentration and volume of NaOH in back-extraction were investigated. Under the optimal experimental conditions, the preconcentration factors were 60.1 for bisphenol-A, 52.7 for β-naphthol, 49.2 for α-naphthol, and 18.0 for 2, 4-dichlorophenol. The limits of detection for bisphenol-A, β-naphthol, α-naphthol and 2, 4-dichlorophenol were 5, 5, 8, and 100 ng mL(-1), respectively. Four kinds of aqueous cosmetics including toner, soften lotion, make-up remover, and perfume were analyzed and yielded recoveries ranging from 81.6% to 119.4%. The main advantages of the proposed method are quick, easy, cheap, and effective. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Salahinejad, Maryam; Aflaki, Fereydoon
2011-06-01
Dispersive liquid-liquid microextraction followed by inductively coupled plasma-optical emission spectrometry has been investigated for determination of Cd(II) ions in water samples. Ammonium pyrrolidine dithiocarbamate was used as chelating agent. Several factors influencing the microextraction efficiency of Cd (II) ions such as extracting and dispersing solvent type and their volumes, pH, sample volume, and salting effect were optimized. The optimization was performed both via one variable at a time, and central composite design methods and the optimum conditions were selected. Both optimization methods showed nearly the same results: sample size 5 mL; dispersive solvent ethanol; dispersive solvent volume 2 mL; extracting solvent chloroform; extracting solvent volume 200 [Formula: see text]L; pH and salt amount do not affect significantly the microextraction efficiency. The limits of detection and quantification were 0.8 and 2.5 ng L( - 1), respectively. The relative standard deviation for five replicate measurements of 0.50 mg L( - 1) of Cd (II) was 4.4%. The recoveries for the spiked real samples from tap, mineral, river, dam, and sea waters samples ranged from 92.2% to 104.5%.
Dose commitments due to radioactive releases from nuclear power plant sites in 1989. Volume 11
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, D.A.
Population and individual radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1989. Fifty-year dose commitments for a one-year exposure from both liquid and atmospheric releases were calculated for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 72 reactor sites. This report tabulates the results of these calculations, showing the dose commitments for both water and airborne pathways for each age group and organ. Also included for each of the sites is an estimate of individual doses which are compared with 10 CFR Partmore » 50, Appendix I design objectives. The total collective dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 14 person-rem to a low of 0.005 person-rem for the sites with plants in operation and producing power during the year. The arithmetic mean was 1.2 person-rem. The total population dose for all sites was estimated at 84 person-rem for the 140 million people considered at risk. The individual dose commitments estimated for all sites were below the Appendix I design objectives.« less
NASA Technical Reports Server (NTRS)
Albright, N.; Concus, P.; Karasalo, I.
1977-01-01
Of principal interest is the stability of a perfectly wetting liquid in an inverted, vertical, right circular-cylindrical container having a concave spheroidal bottom. The mathematical conditions that the contained liquid be in stable static equilibrium are derived, including those for the limiting case of zero contact angle. Based on these results, a computational investigation is carried out for a particular container that is used for the storage of liquid fuels in NASA Centaur space vehicles, for which the axial ratio of the container bottom is 0.724. It is found that for perfectly wetting liquids the qualitative nature of the onset of instability changes at a critical liquid volume, which for the Centaur fuel tank corresponds to a mean fill level of approximately 0.503 times the tank's radius. Small-amplitude periodic sloshing modes for this tank were calculated; oscillation frequencies or growth rates are given for several Bond numbers and liquid volumes, for normal modes having up to six angular nodes.
Environmental Releases for Calendar Year 2001
DOE Office of Scientific and Technical Information (OSTI.GOV)
DYEKMAN, D L
2002-08-01
This report fulfills the annual reporting requirements of US Department of Energy (DOE) Order 5400.1, General Environmental Protection Program. The report contains tabular data summaries on air emissions and liquid effluents released to the environment as well as nonroutine releases during calendar year (CY) 2001. These releases, bearing radioactive and hazardous substances, were from Bechtel Hanford, Inc. (BHI), CH2M HILL Hanford Group, Inc. (CHG), and Fluor Hanford (FH) managed facilities and activities. These data were obtained from direct sampling and analysis and from estimates based upon approved release factors. This report further serves as a supplemental resource to the Hanfordmore » Site Environmental Report (HSER PNNL-13910), published by the Pacific Northwest National Laboratory. HSER includes a yearly accounting of the impacts on the surrounding populace and environment from major activities at the Hanford Site. HSER also summarizes the regulatory compliance status of the Hanford Site. Tables ES-1 through ES-5 display comprehensive data summaries of CY2001 air emission and liquid effluent releases. The data displayed in these tables compiles the following: Radionuclide air emissions; Nonradioactive air emissions; Radionuclides in liquid effluents discharged to ground; Total volumes and flow rates of radioactive liquid effluents discharged to ground; and Radionuclides discharged to the Columbia River.« less
SINDA/FLUINT Stratified Tank Modeling for Cryrogenic Propellant Tanks
NASA Technical Reports Server (NTRS)
Sakowski, Barbara
2014-01-01
A general purpose SINDA/FLUINT (S/F) stratified tank model was created to simulate self-pressurization and axial jet TVS; Stratified layers in the vapor and liquid are modeled using S/F lumps.; The stratified tank model was constructed to permit incorporating the following additional features:, Multiple or singular lumps in the liquid and vapor regions of the tank, Real gases (also mixtures) and compressible liquids, Venting, pressurizing, and draining, Condensation and evaporation/boiling, Wall heat transfer, Elliptical, cylindrical, and spherical tank geometries; Extensive user logic is used to allow detailed tailoring - Don't have to rebuilt everything from scratch!!; Most code input for a specific case is done through the Registers Data Block:, Lump volumes are determined through user input:; Geometric tank dimensions (height, width, etc); Liquid level could be input as either a volume percentage of fill level or actual liquid level height
Metallurgical technologies, energy conversion, and magnetohydrodynamic flows
NASA Astrophysics Data System (ADS)
Branover, Herman; Unger, Yeshajahu
The present volume discusses metallurgical applications of MHD, R&D on MHD devices employing liquid working medium for process applications, electromagnetic (EM) modulation of molten metal flow, EM pump performance of superconducting MHD devices, induction EM alkali-metal pumps, a physical model for EM-driven flow in channel-induction furnaces, grain refinement in Al alloys via EM vibrational method, dendrite growth of solidifying metal in dc magnetic field, MHD for mass and heat transfer in single-crystal melt growth, inverse EM shaping, and liquid-metal MHD development in Israel. Also discussed are the embrittlement of steel by lead, an open cycle MHD disk generator, the acceleration of gas-liquid piston flows for molten-metal MHD generators, MHD flow around a cylinder, new MHD drag coefficients, liquid-metal MHD two-phase flow, and two-phase liquid gas mixers for MHD energy conversion. (No individual items are abstracted in this volume)
Capillary Pressure of a Liquid Between Uniform Spheres Arranged in a Square-Packed Layer
NASA Technical Reports Server (NTRS)
Alexader, J. Iwan D.; Slobozhanin, Lev A.; Collicott, Steven H.
2004-01-01
The capillary pressure in the pores defined by equidimensional close-packed spheres is analyzed numerically. In the absence of gravity the menisci shapes are constructed using Surface Evolver code. This permits calculation the free surface mean curvature and hence the capillary pressure. The dependences of capillary pressure on the liquid volume constructed here for a set of contact angles allow one to determine the evolution of basic capillary characteristics under quasi-static infiltration and drainage. The maximum pressure difference between liquid and gas required for a meniscus passing through a pore is calculated and compared with that for hexagonal packing and with approximate solution given by Mason and Morrow [l]. The lower and upper critical liquid volumes that determine the stability limits for the equilibrium capillary liquid in contact with square packed array of spheres are tabulated for a set of contact angles.
Utilization of Low Gravity Environment for Measuring Liquid Viscosity
NASA Technical Reports Server (NTRS)
Antar, Basil N.; Ethridge, Edwin
1998-01-01
The method of drop coalescence is used for determining the viscosity of highly viscous undercooled liquids. Low gravity environment is necessary in order to allow for examining large volumes affording much higher accuracy for the viscosity calculations than possible for smaller volumes available under 1 - g conditions. The drop coalescence method is preferred over the drop oscillation technique since the latter method can only be applied for liquids with vanishingly small viscosities. The technique developed relies on both the highly accurate solution of the Navier-Stokes equations as well as on data from experiments conducted in near zero gravity environment. Results are presented for method validation experiments recently performed on board the NASA/KC-135 aircraft. While the numerical solution was produced using the Boundary Element Method. In these tests the viscosity of a highly viscous liquid, glycerine at room temperature, was determined using the liquid coalescence method. The results from these experiments will be discussed.
Development and Design of a Zero-G Liquid Quantity Gauge for a Solar Thermal Vehicle
NASA Technical Reports Server (NTRS)
Dodge, Franklin T.; Green, Steven T.; Petullo, Steven P.; VanDresar, Neil T.; Taylor, William J. (Technical Monitor)
2002-01-01
The development and design of a cryogenic liquid quantity gauge for zero-g applications is described. The gauge, named the Compression Mass Gauge (CMG), operates on the principle of slightly changing the volume of the tank by an oscillating bellows. The resulting pressure change is measured and used to predict the volume of vapor in the tank, from which the volume of liquid is computed. For each gauging instance, pressures are measured for several different bellows frequencies to enable minor real-gas effects to be quantified and thereby to obtain a gauging accuracy of +/- 1% of tank volume. Southwest Research Institute (Tm) and NASA-GRC (Glenn Research Center) have developed several previous breadboard and engineering development gauges and tested them in cryogenic hydrogen and nitrogen to establish the gauge capabilities, to resolve several design issues, and to formulate data processing algorithms. The CMG has been selected by NASA's Future X program for a flight demonstration on the USAF (United States Air Force) / Boeing Solar Thermal Vehicle Space Experiment (SOTVSE). This paper reviews the design trade studies needed to satisfy the SOTVSE limitations on CMG power, volume, and mass, and describes the mechanical design of the CMG.
Molecular Volumes and the Stokes-Einstein Equation
ERIC Educational Resources Information Center
Edward, John T.
1970-01-01
Examines the limitations of the Stokes-Einstein equation as it applies to small solute molecules. Discusses molecular volume determinations by atomic increments, molecular models, molar volumes of solids and liquids, and molal volumes. Presents an empirical correction factor for the equation which applies to molecular radii as small as 2 angstrom…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khan, M. F.; Miriyala, N.; Hassanpourfard, M.
Lab-on-a-Chip compatible techniques for thermal characterization of miniaturized volumes of liquid analytes are necessary in applications such as protein blotting, DNA melting, and drug development, where samples are either rare or volume-limited. We developed a closed-chamber calorimeter based on a bimaterial microchannel cantilever (BMC) for sub-nanoliter level thermal analysis. When the liquid-filled BMC is irradiated with infrared (IR) light at a specific wavelength, the IR absorption by the liquid analyte results in localized heat generation and the subsequent deflection of the BMC, due to a thermal expansion mismatch between the constituent materials. The time constant of the deflection, which ismore » dependent upon the heat capacity of the liquid analyte, can be directly measured by recording the time-dependent bending of the BMC. We have used the BMC to quantitatively measure the heat capacity of five volatile organic compounds. With a deflection noise level of ∼10 nm and a signal-to-noise ratio of 68:1, the BMC offers a sensitivity of 30.5 ms/(J g{sup −1 }K{sup −1}) and a resolution of 23 mJ/(g K) for ∼150 pl liquid for heat capacity measurements. This technique can be used for small-scale thermal characterization of different chemical and biological samples.« less
NASA Astrophysics Data System (ADS)
Mahood, Hameed B.; Campbell, A. N.; Baqir, Ali Sh.; Sharif, A. O.; Thorpe, R. B.
2018-06-01
Energy usage is increasing around the world due to the continued development of technology, and population growth. Solar energy is a promising low-grade energy resource that can be harvested and utilised in different applications, such solar heater systems, which are used in both domestic and industrial settings. However, the implementation of an efficient energy conversion system or heat exchanger would enhance such low-grade energy processes. The direct contact heat exchanger could be the right choice due to its ability to efficiently transfer significant amounts of heat, simple design, and low cost. In this work, the heat transfer associated with the direct contact condensation of pentane vapour bubbles in a three-phase direct contact condenser is investigated experimentally. Such a condenser could be used in a cycle with a solar water heater and heat recovery systems. The experiments on the steady state operation of the three-phase direct contact condenser were carried out using a short Perspex tube of 70 cm in total height and an internal diameter of 4 cm. Only a height of 48 cm was active as the direct contact condenser. Pentane vapour, (the dispersed phase) with three different initial temperatures (40° C, 43.5° C and 47.5° C) was directly contacted with water (the continuous phase) at 19° C. The experimental results showed that the total heat transfer rate per unit volume along the direct contact condenser gradually decreased upon moving higher up the condenser. Additionally, the heat transfer rate increases with increasing mass flow rate ratio, but no significant effect on the heat transfer rate of varying the initial temperature of the dispersed phase was seen. Furthermore, both the outlet temperature of the continuous phase and the void fraction were positively correlated with the total heat transfer rate per unit volume, with no considerable effect of the initial temperature difference between the dispersed and continuous phases.
NASA Astrophysics Data System (ADS)
Mahood, Hameed B.; Campbell, A. N.; Baqir, Ali Sh.; Sharif, A. O.; Thorpe, R. B.
2017-12-01
Energy usage is increasing around the world due to the continued development of technology, and population growth. Solar energy is a promising low-grade energy resource that can be harvested and utilised in different applications, such solar heater systems, which are used in both domestic and industrial settings. However, the implementation of an efficient energy conversion system or heat exchanger would enhance such low-grade energy processes. The direct contact heat exchanger could be the right choice due to its ability to efficiently transfer significant amounts of heat, simple design, and low cost. In this work, the heat transfer associated with the direct contact condensation of pentane vapour bubbles in a three-phase direct contact condenser is investigated experimentally. Such a condenser could be used in a cycle with a solar water heater and heat recovery systems. The experiments on the steady state operation of the three-phase direct contact condenser were carried out using a short Perspex tube of 70 cm in total height and an internal diameter of 4 cm. Only a height of 48 cm was active as the direct contact condenser. Pentane vapour, (the dispersed phase) with three different initial temperatures (40° C, 43.5° C and 47.5° C) was directly contacted with water (the continuous phase) at 19° C. The experimental results showed that the total heat transfer rate per unit volume along the direct contact condenser gradually decreased upon moving higher up the condenser. Additionally, the heat transfer rate increases with increasing mass flow rate ratio, but no significant effect on the heat transfer rate of varying the initial temperature of the dispersed phase was seen. Furthermore, both the outlet temperature of the continuous phase and the void fraction were positively correlated with the total heat transfer rate per unit volume, with no considerable effect of the initial temperature difference between the dispersed and continuous phases.
Asadollahzadeh, Mehdi; Tavakoli, Hamed; Torab-Mostaedi, Meisam; Hosseini, Ghaffar; Hemmati, Alireza
2014-06-01
Dispersive-solidification liquid-liquid microextraction (DSLLME) coupled with electrothermal atomic absorption spectrometry (ETAAS) was developed for preconcentration and determination of inorganic arsenic (III, V) in water samples. At pH=1, As(III) formed complex with ammonium pyrrolidine dithiocarbamate (APDC) and extracted into the fine droplets of 1-dodecanol (extraction solvent) which were dispersed with ethanol (disperser solvent) into the water sample solution. After extraction, the organic phase was separated by centrifugation, and was solidified by transferring into an ice bath. The solidified solvent was transferred to a conical vial and melted quickly at room temperature. As(III) was determined in the melted organic phase while As(V) remained in the aqueous layer. Total inorganic As was determined after the reduction of the pentavalent forms of arsenic with sodium thiosulphate and potassium iodide. As(V) was calculated by difference between the concentration of total inorganic As and As(III). The variable of interest in the DSLLME method, such as the volume of extraction solvent and disperser solvent, pH, concentration of APDC (chelating agent), extraction time and salt effect, was optimized with the aid of chemometric approaches. First, in screening experiments, fractional factorial design (FFD) was used for selecting the variables which significantly affected the extraction procedure. Afterwards, the significant variables were optimized using response surface methodology (RSM) based on central composite design (CCD). In the optimum conditions, the proposed method has been successfully applied to the determination of inorganic arsenic in different environmental water samples and certified reference material (NIST RSM 1643e). Copyright © 2014 Elsevier B.V. All rights reserved.
Determination of the thermal stability of fluids by tensimetry - Instrumentation and procedure
NASA Technical Reports Server (NTRS)
Helmick, Larry S.; Jones, William R., Jr.
1990-01-01
A computerized tensimeter and experimental procedure for determination of the thermal decomposition temperature (T sub d) of perfluoro alkylethers were developed and tested. Both the apparatus and the procedure are described in detail. Results of testing with bis(2-ethylhexyl) phthalate and trimethylolpropane triheptanoate demonstrate that the reciprocal of the decomposition temperature is a linear function of the logarithm of the gas volume/heated liquid volume ratio. The T sub d obtained for each compound at a gas volume/heated liquid volume ration of one was similar to the value previously reported using an isoteniscope technique. Results of testing with a polymer of hexafluoropropylene oxide demonstrate that this instrument and procedure can be used to determine the T sub d of perfluoro alkylethers.
NASA Technical Reports Server (NTRS)
Helmick, Larry S.; Jones, William R., Jr.
1989-01-01
A computerized tensimeter and experimental procedure for determination of the thermal decomposition temperature (T sub d) of perfluoro alkylethers were developed and tested. Both the apparatus and the procedure are described in detail. Results of testing with bis(2-ethylhexyl) phthalate and trimethylolpropane triheptanoate demonstrate that the reciprocal of the decomposition temperature is a linear function of the logarithm of the gas volume/heated liquid volume ratio. The T sub d obtained for each compound at a gas volume/heated liquid volume ration of one was similar to the value previously reported using an isoteniscope technique. Results of testing with a polymer of hexafluoropropylene oxide demonstrate that this instrument and procedure can be used to determine the T sub d of perfluoroalkylethers.
Comparing volume of fluid and level set methods for evaporating liquid-gas flows
NASA Astrophysics Data System (ADS)
Palmore, John; Desjardins, Olivier
2016-11-01
This presentation demonstrates three numerical strategies for simulating liquid-gas flows undergoing evaporation. The practical aim of this work is to choose a framework capable of simulating the combustion of liquid fuels in an internal combustion engine. Each framework is analyzed with respect to its accuracy and computational cost. All simulations are performed using a conservative, finite volume code for simulating reacting, multiphase flows under the low-Mach assumption. The strategies used in this study correspond to different methods for tracking the liquid-gas interface and handling the transport of the discontinuous momentum and vapor mass fractions fields. The first two strategies are based on conservative, geometric volume of fluid schemes using directionally split and un-split advection, respectively. The third strategy is the accurate conservative level set method. For all strategies, special attention is given to ensuring the consistency between the fluxes of mass, momentum, and vapor fractions. The study performs three-dimensional simulations of an isolated droplet of a single component fuel evaporating into air. Evaporation rates and vapor mass fractions are compared to analytical results.
Foster, Gregory D.; Gates, Paul M.; Foreman, William T.; McKenzie, Stuart W.; Rinella, Frank A.
1993-01-01
Concentrations of pesticides in the dissolved phase of surface water samples from the Yakima River basin, WA, were determined using preconcentration in the Goulden large-sample extractor (GLSE) and gas chromatography/mass spectrometry (GC/MS) analysis. Sample volumes ranging from 10 to 120 L were processed with the GLSE, and the results from the large-sample analyses were compared to those derived from 1-L continuous liquid-liquid extractions Few of the 40 target pesticides were detected in 1-L samples, whereas large-sample preconcentration in the GLSE provided detectable levels for many of the target pesticides. The number of pesticides detected in GLSE processed samples was usually directly proportional to sample volume, although the measured concentrations of the pesticides were generally lower at the larger sample volumes for the same water source. The GLSE can be used to provide lower detection levels relative to conventional liquid-liquid extraction in GC/MS analysis of pesticides in samples of surface water.
NASA Astrophysics Data System (ADS)
Schiebl, M.; Zelenka, Z.; Buchner, C.; Pohl, R.; Steindl, D.
2018-02-01
In this study, the influence of the unknown sinker temperature on the measured density of liquids is evaluated. Generally, due to the intrinsic temperature instability of the heat bath temperature controller, the system will never reach thermal equilibrium but instead will oscillate around a mean temperature. The sinker temperature follows this temperature oscillation with a certain time lag. Since the sinker temperature is not measured directly in a hydrostatic weighing apparatus, the temperature of the sinker, and thus in turn the volume of the sinker, is not known exactly. As a consequence, this leads to uncertainty in the value of the density of the liquid. From an analysis of the volume relaxation of the sinker immersed into a heat bath with time-dependent temperature characteristics, the heat transfer coefficient can be estimated, and thus a characteristic time constant for achieving quasi thermal equilibrium for a hydrostatic weighing apparatus is proposed. Additionally, from a theoretical analysis of the transient behavior of the sinker volume, the systematic deviation of the theoretical to the actual measured liquid density is calculated.
Integrated acoustic phase separator and multiphase fluid composition monitoring apparatus and method
Sinha, Dipen N.
2016-01-12
An apparatus and method for down hole gas separation from the multiphase fluid flowing in a wellbore or a pipe, for determining the quantities of the individual components of the liquid and the flow rate of the liquid, and for remixing the component parts of the fluid after which the gas volume may be measured, without affecting the flow stream, are described. Acoustic radiation force is employed to separate gas from the liquid, thereby permitting measurements to be separately made for these two components; the liquid (oil/water) composition is determined from ultrasonic resonances; and the gas volume is determined from capacitance measurements. Since the fluid flows around and through the component parts of the apparatus, there is little pressure difference, and no protection is required from high pressure differentials.
Integrated acoustic phase separator and multiphase fluid composition monitoring apparatus and method
Sinha, Dipen N
2014-02-04
An apparatus and method for down hole gas separation from the multiphase fluid flowing in a wellbore or a pipe, for determining the quantities of the individual components of the liquid and the flow rate of the liquid, and for remixing the component parts of the fluid after which the gas volume may be measured, without affecting the flow stream, are described. Acoustic radiation force is employed to separate gas from the liquid, thereby permitting measurements to be separately made for these two components; the liquid (oil/water) composition is determined from ultrasonic resonances; and the gas volume is determined from capacitance measurements. Since the fluid flows around and through the component parts of the apparatus, there is little pressure difference, and no protection is required from high pressure differentials.
NASA Astrophysics Data System (ADS)
Hurt, S. M.; Lange, R. A.; Ai, Y.
2015-12-01
The volumetric properties of multi-component carbonate liquids are required to extend thermodynamic models that describe partial melting of the deep mantle (e.g. pMELTS; Ghiorso et al., 2003) to carbonate-bearing lithologies. Carbonate in the mantle is an important reservoir of carbon, which is released to the atmosphere as CO2 through volcanism, and thus contributes to the carbon cycle. Although MgCO3 is the most important carbonate component in the mantle, it is not possible to directly measure the 1-bar density and compressibility of MgCO3 liquid because, like other alkaline-earth carbonates, it decomposes at a temperature lower than its melting temperature. Despite this challenge, Liu and Lange (2003) and O'Leary et al. (2015) showed that the one bar molar volume, thermal expansion and compressibility of the CaCO3 liquid component could be obtained by measuring the density and sound speeds of stable liquids in the CaCO3-Li2CO3-Na2CO3-K2CO3 quaternary system at one bar. In this study, this same strategy is employed on SrCO3- and BaCO3-bearing alkali carbonate liquids. The density and sound speed of seven liquids in the SrCO3-Li2CO3-Na2CO3-K2CO3 quaternary and three liquids in the BaCO3-Li2CO3-Na2CO3-K2CO3 quaternary were measured from 739-1367K, with SrCO3 and BaCO3 concentrations ranging from 10-50 mol%. The density measurements were made using the double-bob Archimedean method and sound speeds were obtained with a frequency-sweep acoustic interferometer. The molar volume and sound speed measurements were used to calculate the isothermal compressibility of each liquid, and the results show the volumetric properties mix ideally with composition. The partial molar volume and compressibility of the SrCO3 and BaCO3 components are compared to those obtained for the CaCO3 component as a function of cation field strength. The results reveal a systematic trend that allows the partial molar volume and compressibility of the MgCO3 liquid component to be estimated.
Razmi, Rasoul; Shahpari, Behrouz; Pourbasheer, Eslam; Boustanifar, Mohammad Hasan; Azari, Zhila; Ebadi, Amin
2016-11-01
A rapid and simple method for the extraction and preconcentration of ceftazidime in aqueous samples has been developed using dispersive liquid-liquid microextraction followed by high-performance liquid chromatography analysis. The extraction parameters, such as the volume of extraction solvent and disperser solvent, salt effect, sample volume, centrifuge rate, centrifuge time, extraction time, and temperature in the dispersive liquid-liquid microextraction process, were studied and optimized with the experimental design methods. Firstly, for the preliminary screening of the parameters the taguchi design was used and then, the fractional factorial design was used for significant factors optimization. At the optimum conditions, the calibration curves for ceftazidime indicated good linearity over the range of 0.001-10 μg/mL with correlation coefficients higher than the 0.98, and the limits of detection were 0.13 and 0.17 ng/mL, for water and urine samples, respectively. The proposed method successfully employed to determine ceftazidime in water and urine samples and good agreement between the experimental data and predictive values has been achieved. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Peyrot des Gachons, Catherine; Avrillier, Julie; Gleason, Michael; Algarra, Laure; Zhang, Siyu; Mura, Emi; Nagai, Hajime
2016-01-01
Fluid ingestion is necessary for life, and thirst sensations are a prime motivator to drink. There is evidence of the influence of oropharyngeal stimulation on thirst and water intake in both animals and humans, but how those oral sensory cues impact thirst and ultimately the amount of liquid ingested is not well understood. We investigated which sensory trait(s) of a beverage influence the thirst quenching efficacy of ingested liquids and the perceived amount ingested. We deprived healthy individuals of liquid and food overnight (> 12 hours) to make them thirsty. After asking them to drink a fixed volume (400 mL) of an experimental beverage presenting one or two specific sensory traits, we determined the volume ingested of additional plain, ‘still’, room temperature water to assess their residual thirst and, by extension, the thirst-quenching properties of the experimental beverage. In a second study, participants were asked to drink the experimental beverages from an opaque container through a straw and estimate the volume ingested. We found that among several oro-sensory traits, the perceptions of coldness, induced either by cold water (thermally) or by l-menthol (chemically), and the feeling of oral carbonation, strongly enhance the thirst quenching properties of a beverage in water-deprived humans (additional water intake after the 400 ml experimental beverage was reduced by up to 50%). When blinded to the volume of liquid consumed, individual’s estimation of ingested volume is increased (~22%) by perceived oral cold and carbonation, raising the idea that cold and perhaps CO2 induced-irritation sensations are included in how we normally encode water in the mouth and how we estimate the quantity of volume swallowed. These findings have implications for addressing inadequate hydration state in populations such as the elderly. PMID:27685093
NASA Technical Reports Server (NTRS)
Rosevear, Jerry
1992-01-01
Given here is a definition of Liquid Air Cycle Engines (LACE) and existing relevant technologies. Heat exchanger design and fabrication techniques, the handling of liquid hydrogen to achieve the greatest heat sink capabilities, and air decontamination to prevent heat exchanger fouling are discussed. It was concluded that technology needs to be extended in the areas of design and fabrication of heat exchangers to improve reliability along with weight and volume reductions. Catalysts need to be improved so that conversion can be achieved with lower quantities and lower volumes. Packaging studies need to be investigated both analytically and experimentally. Recycling with slush hydrogen needs further evaluation with experimental testing.
NASA Technical Reports Server (NTRS)
Koepler, Jack L. (Inventor); Hill, Robert L. (Inventor)
1981-01-01
A tool to assist in the servicing of a shock absorber wherein the shock absorber is constructed of a pair of aligned gas and liquid filled chambers. Each of the chambers is separated by a movable separator member. Maximum efficiency of the shock absorber is achieved in the locating of a precise volume of gas within the gas chamber and a precise volume of liquid within the liquid chamber. The servicing tool of this invention employs a rod which is to connect with the separator and by observation of the position of the rod with respect to the gauge body, the location of the separator is ascertained even though it is not directly observable.
Phosphorus transfer in runoff following application of fertilizer, manure, and sewage sludge.
Withers, P J; Clay, S D; Breeze, V G
2001-01-01
Phosphorus (P) transfer in surface runoff from field plots receiving either no P, triplesuperphoshate (TSP), liquid cattle manure (LCS), liquid anaerobically digested sludge (LDS), or dewatered sludge cake (DSC) was compared over a 2-yr period. Dissolved inorganic P concentrations in runoff increased from 0.1 to 0.2 mg L(-1) on control and sludge-treated plots to 3.8 and 6.5 mg L(-1) following application of LCS and TSP, respectively, to a cereal crop in spring. When incorporated into the soil in autumn, runoff dissolved P concentrations were typically < 0.5 mg L(-1) across all plots, and particulate P remained the dominant P form. When surface-applied in autumn to a consolidated seedbed, direct loss of LCS and LDS increased both runoff volume and P transfers, but release of dissolved P occurred only from LCS. The largest P concentrations (>70 mg L(-1)) were recorded following TSP application without any increase in runoff volume, while application of bulky DSC significantly reduced total P transfers by 70% compared with the control due to a reduced runoff volume. Treatment effects in each monitoring period were most pronounced in the first runoff event. Differences in the release of P from the different P sources were related to the amounts of P extracted by either water or sodium bicarbonate in the order TSP > LCS > LDS > DSC. The results suggest there is a lower risk of P transfer in land runoff following application of sludge compared with other agricultural P amendments at similar P rates.
Manufacture and Testing of an Activation Foil Package for Use in AFIDS
2005-03-01
Miller. Nuclides and Isotopes , 16th ed. Lockheed Martin, 2002. 4. Broadhead, Bryan. Sr. Development Staff, Reactor and Fuel Cycle Analysis ...alternative, the concept of using liquid nitrous oxide inside a reactor to simulate large volumes of air was investigated. Simulation using the...weapon. We analyzed whether N2O could replicate large volumes of air in neutron transport experiments since one cubic centimeter of liquid N2O
Liquid rocket booster integration study. Volume 4: Reviews and presentation material
NASA Technical Reports Server (NTRS)
1988-01-01
Liquid rocket booster integration study is presented. Volume 4 contains materials presented at the MSFC/JSC/KSC Integrated Reviews and Working Group Sessions, and the Progress Reviews presented to the KSC Study Manager. The following subject areas are covered: initial impact assessment; conflicts with the on-going STS mission; access to the LRB at the PAD; the activation schedule; transition requirements; cost methodology; cost modelling approach; and initial life cycle cost.
Expanding the calculation of activation volumes: Self-diffusion in liquid water
NASA Astrophysics Data System (ADS)
Piskulich, Zeke A.; Mesele, Oluwaseun O.; Thompson, Ward H.
2018-04-01
A general method for calculating the dependence of dynamical time scales on macroscopic thermodynamic variables from a single set of simulations is presented. The approach is applied to the pressure dependence of the self-diffusion coefficient of liquid water as a particularly useful illustration. It is shown how the activation volume associated with diffusion can be obtained directly from simulations at a single pressure, avoiding approximations that are typically invoked.
Melting properties of Pt and its transport coefficients in liquid states under high pressures
NASA Astrophysics Data System (ADS)
Wang, Pan-Pan; Shao, Ju-Xiang; Cao, Qi-Long
2016-11-01
Molecular dynamics (MD) simulations of the melting and transport properties in liquid states of platinum for the pressure range (50-200 GPa) are reported. The melting curve of platinum is consistent with previous ab initio MD simulation results and the first-principles melting curve. Calculated results for the pressure dependence of fusion entropy and fusion volume show that the fusion entropy and the fusion volume decrease with increasing pressure, and the ratio of the fusion volume to fusion entropy roughly reproduces the melting slope, which has a moderate decrease along the melting line. The Arrhenius law well describes the temperature dependence of self-diffusion coefficients and viscosity under high pressure, and the diffusion activation energy decreases with increasing pressure, while the viscosity activation energy increases with increasing pressure. In addition, the entropy-scaling law, proposed by Rosenfeld under ambient pressure, still holds well for liquid Pt under high pressure conditions.
Borodin, Oleg
2009-09-10
A number of correlations between heat of vaporization (H(vap)), cation-anion binding energy (E(+/-)), molar volume (V(m)), self-diffusion coefficient (D), and ionic conductivity for 29 ionic liquids have been investigated using molecular dynamics (MD) simulations that employed accurate and validated many-body polarizable force fields. A significant correlation between D and H(vap) has been found, while the best correlation was found for -log(DV(m)) vs H(vap) + 0.28E(+/-). A combination of enthalpy of vaporization and a fraction of the cation-anion binding energy was suggested as a measure of the effective cohesive energy for ionic liquids. A deviation of some ILs from the reported master curve is explained based upon ion packing and proposed diffusion pathways. No general correlations were found between the ion diffusion coefficient and molecular volume or the diffusion coefficient and cation/anion binding energy.
Jiang, Zheng; Wang, Hong; Wu, Qi-nan
2015-06-01
To optimize the processing of polysaccharide extraction from Spirodela polyrrhiza. Five factors related to extraction rate of polysaccharide were optimized by the Plackett-Burman design. Based on this study, three factors, including alcohol volume fraction, extraction temperature and ratio of material to liquid, were regarded as investigation factors by Box-Behnken response surface methodology. The effect order of three factors on the extraction rate of polysaccharide from Spirodela polyrrhiza were as follows: extraction temperature, alcohol volume fraction,ratio of material to liquid. According to Box-Behnken response, the best extraction conditions were: alcohol volume fraction of 81%, ratio of material to liquid of 1:42, extraction temperature of 100 degrees C, extraction time of 60 min for four times. Plackett-Burman design and Box-Behnken response surface methodology used to optimize the extraction process for the polysaccharide in this study is effective and stable.
Axial jet mixing of ethanol in cylindrical containers during weightlessness
NASA Technical Reports Server (NTRS)
Aydelott, J. C.
1979-01-01
An experimental program was conducted to examine the liquid flow patterns that result from the axial jet mixing of ethanol in 10-centimeter-diameter cylindrical tanks in weightlessness. A convex hemispherically ended tank and two Centaur liquid-hydrogen-tank models were used for the study. Four distinct liquid flow patterns were observed to be a function of the tank geometry, the liquid-jet velocity, the volume of liquid in the tank, and the location of the tube from which the liquid jet exited.
None
2016-03-22
An apparatus for generating a large volume of gas from a liquid stream is disclosed. The apparatus includes a first channel through which the liquid stream passes. The apparatus also includes a layer of catalyst particles suspended in a solid slurry for generating gas from the liquid stream. The apparatus further includes a second channel through which a mixture of converted liquid and generated gas passes. A heat exchange channel heats the liquid stream. A wicking structure located in the second channel separates the gas generated from the converted liquid.
Mudie, Deanna M; Murray, Kathryn; Hoad, Caroline L; Pritchard, Susan E; Garnett, Martin C; Amidon, Gordon L; Gowland, Penny A; Spiller, Robin C; Amidon, Gregory E; Marciani, Luca
2014-09-02
The rate and extent of drug dissolution and absorption from solid oral dosage forms is highly dependent upon the volumes and distribution of gastric and small intestinal water. However, little is known about the time courses and distribution of water volumes in vivo in an undisturbed gut. Previous imaging studies offered a snapshot of water distribution in fasted humans and showed that water in the small intestine is distributed in small pockets. This study aimed to quantify the volume and number of water pockets in the upper gut of fasted healthy humans following ingestion of a glass of water (240 mL, as recommended for bioavailability/bioequivalence (BA/BE) studies), using recently validated noninvasive magnetic resonance imaging (MRI) methods. Twelve healthy volunteers underwent upper and lower abdominal MRI scans before drinking 240 mL (8 fluid ounces) of water. After ingesting the water, they were scanned at intervals for 2 h. The drink volume, inclusion criteria, and fasting conditions matched the international standards for BA/BE testing in healthy volunteers. The images were processed for gastric and intestinal total water volumes and for the number and volume of separate intestinal water pockets larger than 0.5 mL. The fasted stomach contained 35 ± 7 mL (mean ± SEM) of resting water. Upon drinking, the gastric fluid rose to 242 ± 9 mL. The gastric water volume declined rapidly after that with a half emptying time (T50%) of 13 ± 1 min. The mean gastric volume returned back to baseline 45 min after the drink. The fasted small bowel contained a total volume of 43 ± 14 mL of resting water. Twelve minutes after ingestion of water, small bowel water content rose to a maximum value of 94 ± 24 mL contained within 15 ± 2 pockets of 6 ± 2 mL each. At 45 min, when the glass of water had emptied completely from the stomach, total intestinal water volume was 77 ± 15 mL distributed into 16 ± 3 pockets of 5 ± 1 mL each. MRI provided unprecedented insights into the time course, number, volume, and location of water pockets in the stomach and small intestine under conditions that represent standard BA/BE studies using validated techniques. These data add to our current understanding of gastrointestinal physiology and will help improve physiological relevance of in vitro testing methods and in silico transport analyses for prediction of bioperformance of oral solid dosage forms, particularly for low solubility Biopharmaceutics Classification System (BCS) Class 2 and Class 4 compounds.
Chemical Method of Urine Volume Measurement
NASA Technical Reports Server (NTRS)
Petrack, P.
1967-01-01
A system has been developed and qualified as flight hardware for the measurement of micturition volumes voided by crewmen during Gemini missions. This Chemical Urine Volume Measurement System (CUVMS) is used for obtaining samples of each micturition for post-flight volume determination and laboratory analysis for chemical constituents of physiological interest. The system is versatile with respect to volumes measured, with a capacity beyond the largest micturition expected to be encountered, and with respect to mission duration of inherently indefinite length. The urine sample is used for the measurement of total micturition volume by a tracer dilution technique, in which a fixed, predetermined amount of tritiated water is introduced and mixed into the voided urine, and the resulting concentration of the tracer in the sample is determined with a liquid scintillation spectrometer. The tracer employed does not interfere with the analysis for the chemical constituents of the urine. The CUVMS hardware consists of a four-way selector valve in which an automatically operated tracer metering pump is incorporated, a collection/mixing bag, and tracer storage accumulators. The assembled system interfaces with a urine receiver at the selector valve inlet, sample bags which connect to the side of the selector valve, and a flexible hose which carries the excess urine to the overboard drain connection. Results of testing have demonstrated system volume measurement accuracy within the specification limits of +/-5%, and operating reliability suitable for system use aboard the GT-7 mission, in which it was first used.
Midttun, Øivind; McCann, Adrian; Aarseth, Ove; Krokeide, Marit; Kvalheim, Gry; Meyer, Klaus; Ueland, Per M
2016-11-01
Targeted metabolic profiling characterized by complementary platforms, multiplexing and low volume consumption are increasingly used for studies using biobank material. Using liquid-liquid extraction, we developed a sample workup suitable for quantification of 6 fat- and 26 water-soluble biomarkers. 50 μL of serum/plasma was mixed with dithioerythritol, ethanol, and isooctane/chloroform. The organic layer was used for analysis of the fat-soluble vitamins all-trans retinol (A), 25-hydroxyvitamin D2, 25-hydroxyvitamin D3, α-tocopherol (E), γ-tocopherol (E), and phylloquinone (K1) by LC-MS/MS. The remaining aqueous fraction was mixed with ethanol, water, pyridine, and methylchloroformate (in toluene) to derivatize the water-soluble biomarkers. The resulting toluene layer was used for GC-MS/MS analysis of alanine, α-ketoglutarate, asparagine, aspartic acid, cystathionine, total cysteine, glutamic acid, glutamine, glycine, histidine, total homocysteine, isoleucine, kynurenine, leucine, lysine, methionine, methylmalonic acid, ornithine, phenylalanine, proline, sarcosine, serine, threonine, tryptophan, tyrosine, and valine. Isotope-labeled internal standards were used for all analytes. Chromatographic run times for the LC-MS/MS and GC-MS/MS were 4.5 and 11 min, respectively. The limits of detection (LOD) for the low-concentration analytes (25-hydroxyvitamin D2, 25-hydroxyvitamin D3, and phylloquinone) were 25, 17, and 0.33 nM, respectively, while all other analytes demonstrated sensitivity significantly lower than endogenous concentrations. Recoveries ranged from 85.5-109.9% and within- and between-day coefficients of variance (CVs) were 0.7-9.4% and 1.1-17.5%, respectively. This low-volume, high-throughput multianalyte assay is currently in use in our laboratory for quantification of 32 serum/plasma biomarkers in epidemiological studies.
Code of Federal Regulations, 2011 CFR
2011-07-01
... shall have the meaning given them in the Act and in this section. Capacity means the volume of liquid... or emptying means the partial or complete removal of stored liquid from a storage vessel. Storage vessels that contain liquid only as wall or bottom clingage, or in pools due to bottom irregularities, are...
Code of Federal Regulations, 2013 CFR
2013-07-01
... shall have the meaning given them in the Act and in this section. Capacity means the volume of liquid... or emptying means the partial or complete removal of stored liquid from a storage vessel. Storage vessels that contain liquid only as wall or bottom clingage, or in pools due to bottom irregularities, are...
Code of Federal Regulations, 2014 CFR
2014-07-01
... shall have the meaning given them in the Act and in this section. Capacity means the volume of liquid... or emptying means the partial or complete removal of stored liquid from a storage vessel. Storage vessels that contain liquid only as wall or bottom clingage, or in pools due to bottom irregularities, are...
Code of Federal Regulations, 2010 CFR
2010-07-01
... shall have the meaning given them in the Act and in this section. Capacity means the volume of liquid... or emptying means the partial or complete removal of stored liquid from a storage vessel. Storage vessels that contain liquid only as wall or bottom clingage, or in pools due to bottom irregularities, are...
Code of Federal Regulations, 2012 CFR
2012-07-01
... shall have the meaning given them in the Act and in this section. Capacity means the volume of liquid... or emptying means the partial or complete removal of stored liquid from a storage vessel. Storage vessels that contain liquid only as wall or bottom clingage, or in pools due to bottom irregularities, are...
NASA Technical Reports Server (NTRS)
Ohsaka, K.; Chung, S. K.; Rhim, W. K.; Johnson, W. L.; Peker, A.; Scruggs, D.
1997-01-01
The specific volumes of the Zr(41.2)Ti(3.8)Cu(2.5)Ni(10.0)Be(22.5) alloy as a function of temperature, T, are determined by employing an image digitizing technique and numerical calculation methods applied to the electrostatically levitated spherical alloy. The linear fitting of the volumes of the alloy in the liquid, V(sub l), glass, V(sub g) and crystalline V(sub c), states in the temperature ranges shown in parentheses are V(sub l)(T) = 0.1583 + 8.877 x 10(exp -6) T(cu cm/g) (700-1300 K);V(sub g)(T) = 0.1603 + 5.528 x 10(exp -6) T (400-550 K);V(sub c)(T) = 0.1583 + 6.21 x 10(exp -6)T(400-850 K). The average volume thermal expansion coefficients within the temperature ranges are determined to be 5.32, 3.39. and 3.83 x 10(exp -5) (1/K) for the liquid, glass, and crystalline states, respectively.
NASA Technical Reports Server (NTRS)
Cocchiaro, James E. (Editor); Mulder, Edwin J. (Editor); Gomez-Knight, Sylvia J. (Editor)
1999-01-01
This volume contains 37 unclassified/unlimited-distribution technical papers that were presented at the JANNAF 28th Propellant Development & Characterization Subcommittee (PDCS) and 17th Safety & Environmental Protection Subcommittee (S&EPS) Joint Meeting, held 26-30 April 1999 at the Town & Country Hotel and the Naval Submarine Base, San Diego, California. Volume II contains 29 unclassified/limited-distribution papers that were presented at the 28th PDCS and 17th S&EPS Joint Meeting. Volume III contains a classified paper that was presented at the 28th PDCS Meeting on 27 April 1999. Topics covered in PDCS sessions include: solid propellant rheology; solid propellant surveillance and aging; propellant process engineering; new solid propellant ingredients and formulation development; reduced toxicity liquid propellants; characterization of hypergolic propellants; and solid propellant chemical analysis methods. Topics covered in S&EPS sessions include: space launch range safety; liquid propellant hazards; vapor detection methods for toxic propellant vapors and other hazardous gases; toxicity of propellants, ingredients, and propellant combustion products; personal protective equipment for toxic liquid propellants; and demilitarization/treatment of energetic material wastes.
Schaper, J. Niklas; Pfeuffer, Kevin P.; Shelley, Jacob T.; Bings, Nicolas H.
2012-01-01
One of the fastest developing fields in analytical spectrochemistry in recent years is ambient desorption/ionization mass spectrometry (ADI-MS). This burgeoning interest has been due to the demonstrated advantages of the method: simple mass spectra, little or no sample preparation, and applicability to samples in the solid, liquid, or gaseous state. One such ADI-MS source, the flowing atmospheric-pressure afterglow (FAPA), is capable of direct analysis of solids just by aiming the source at the solid surface and sampling the produced ions into a mass spectrometer. However, direct introduction of significant volumes of liquid samples into this source has not been possible, as solvent loads can quench the afterglow and, thus, the formation of reagent ions. As a result, the analysis of liquid samples is preferably carried out by analyzing dried residues or by desorbing small amounts of liquid samples directly from the liquid surface. In the former case, reproducibility of sample introduction is crucial if quantitative results are desired. In the present study, introduction of liquid samples as very small droplets helps overcome the issues of sample positioning and reduced levels of solvent intake. A recently developed “drop-on-demand” (DOD) aerosol generator is capable of reproducibly producing very small volumes of liquid (~17 pL). In this paper, the coupling of FAPA-MS and DOD is reported and applications are suggested. Analytes representing different classes of substances were tested and limits of detections were determined. Matrix tolerance was investigated for drugs of abuse and their metabolites by analyzing raw urine samples and quantification without the use of internal standards. Limits of detection below 2 µg/mL, without sample pretreatment, were obtained. PMID:23025277
Azizan, Amizon; Büchs, Jochen
2017-01-01
Biotechnological development in shake flask necessitates vital engineering parameters e.g. volumetric power input, mixing time, gas liquid mass transfer coefficient, hydromechanical stress and effective shear rate. Determination and optimization of these parameters through experiments are labor-intensive and time-consuming. Computational Fluid Dynamics (CFD) provides the ability to predict and validate these parameters in bioprocess engineering. This work provides ample experimental data which are easily accessible for future validations to represent the hydrodynamics of the fluid flow in the shake flask. A non-invasive measuring technique using an optical fluorescence method was developed for shake flasks containing a fluorescent solution with a waterlike viscosity at varying filling volume (V L = 15 to 40 mL) and shaking frequency ( n = 150 to 450 rpm) at a constant shaking diameter (d o = 25 mm). The method detected the leading edge (LB) and tail of the rotating bulk liquid (TB) relative to the direction of the centrifugal acceleration at varying circumferential heights from the base of the shake flask. The determined LB and TB points were translated into three-dimensional (3D) circumferential liquid distribution plots. The maximum liquid height (H max ) of the bulk liquid increased with increasing filling volume and shaking frequency of the shaking flask, as expected. The toroidal shapes of LB and TB are clearly asymmetrical and the measured TB differed by the elongation of the liquid particularly towards the torus part of the shake flask. The 3D liquid distribution data collected at varying filling volume and shaking frequency, comprising of LB and TB values relative to the direction of the centrifugal acceleration are essential for validating future numerical solutions using CFD to predict vital engineering parameters in shake flask.
Control of ice chromatographic retention mechanism by changing temperature and dopant concentration.
Tasaki, Yuiko; Okada, Tetsuo
2011-12-15
A liquid phase coexists with solid water ice in a typical binary system, such as NaCl-water, in the temperature range between the freezing point and the eutectic point (t(eu)) of the system. In ice chromatography with salt-doped ice as the stationary phase, both solid and liquid phase can contribute to solute retention in different fashions; that is, the solid ice surface acts as an adsorbent, while a solute can be partitioned into the liquid phase. Thus, both adsorption and partition mechanisms can be utilized for ice chromatographic separation. An important feature in this approach is that the liquid phase volume can be varied by changing the temperature and the concentration of a salt incorporated into the ice stationary phase. Thus, we can control the relative contribution from the partition mechanism in the entire retention because the liquid phase volume can be estimated from the freezing depression curve. Separation selectivity can thereby be modified. The applicability of this concept has been confirmed for the solutes of different adsorption and partition abilities. The predicted retention based on thermodynamics basically agrees well with the corresponding experimental retention. However, one important inconsistency has been found. The calculation predicts a step-like discontinuity of the solute retention at t(eu) because the phase diagram suggests that the liquid phase abruptly appears at t(eu) when the temperature increases. In contrast, the corresponding experimental plots are continuous over the wider range including the subeutectic temperatures. This discrepancy is explained by the existence of the liquid phase below t(eu). A difference between predicted and measured retention factors allows the estimation of the volume of the subeutectic liquid phase.
Suspended Microchannel Resonators for Ultralow Volume Universal Detection
Son, Sungmin; Grover, William H.; Burg, Thomas P.; Manalis, Scott R.
2008-01-01
Universal detectors that maintain high sensitivity as the detection volume is reduced to the subnanoliter scale can enhance the utility of miniaturized total analysis systems (μ-TAS). Here the unique scaling properties of the suspended microchannel resonator (SMR) are exploited to show universal detection in a 10 pL analysis volume with a density detection limit of ∼1 μg/cm3 (10 Hz bandwidth) and a dynamic range of 6 decades. Analytes with low UV extinction coefficients such as polyethylene glycol (PEG) 8 kDa, glucose, and glycine are measured with molar detection limits of 0.66, 13.5, and 31.6 μM, respectively. To demonstrate the potential for real-time monitoring, gel filtration chromatography was used to separate different molecular weights of PEG as the SMR acquired a chromatogram by measuring the eluate density. This work suggests that the SMR could offer a simple and sensitive universal detector for various separation systems from liquid chromatography to capillary electrophoresis. Moreover, since the SMR is itself a microfluidic channel, it can be directly integrated into μ-TAS without compromising overall performance. PMID:18489125
Core Formation on Asteroid 4 Vesta: Iron Rain in a Silicate Magma Ocean
NASA Technical Reports Server (NTRS)
Kiefer, Walter S.; Mittlefehldt, David W.
2017-01-01
Geochemical observations of the eucrite and diogenite meteorites, together with observations made by NASA's Dawn spacecraft, suggest that Vesta resembles H chondrites in bulk chemical composition, possibly with about 25% of a CM-chondrite like composition added in. For this model, the core is 15% by mass (or 8 volume %) of the asteroid. The abundances of moderately siderophile elements (Ni, Co, Mo, W, and P) in eucrites require that essentially all of the metallic phase in Vesta segregated to form a core prior to eucrite solidification. Melting in the Fe-Ni-S system begins at a cotectic temperature of 940 deg. C. Only about 40% of the total metal phase, or 3-4 volume % of Vesta, melts prior to the onset of silicate melting. Liquid iron in solid silicate initially forms isolated pockets of melt; connected melt channels, which are necessary if the metal is to segregate from the silicate, are only possible when the metal phase exceeds about 5 volume %. Thus, metal segregation to form a core does not occur prior to the onset of silicate melting.
Xu, Xu; Su, Rui; Zhao, Xin; Liu, Zhuang; Zhang, Yupu; Li, Dan; Li, Xueyuan; Zhang, Hanqi; Wang, Ziming
2011-11-30
The ionic liquid-based microwave-assisted dispersive liquid-liquid microextraction (IL-based MADLLME) and derivatization was applied for the pretreatment of six sulfonamides (SAs) prior to the determination by high-performance liquid chromatography (HPLC). By adding methanol (disperser), fluorescamine solution (derivatization reagent) and ionic liquid (extraction solvent) into sample, extraction, derivatization, and preconcentration were continuously performed. Several experimental parameters, such as the type and volume of extraction solvent, the type and volume of disperser, amount of derivatization reagent, microwave power, microwave irradiation time, pH of sample solution, and ionic strength were investigated and optimized. When the microwave power was 240 W, the analytes could be derivatized and extracted simultaneously within 90 s. The proposed method was applied to the analysis of river water, honey, milk, and pig plasma samples, and the recoveries of analytes obtained were in the range of 95.0-110.8, 95.4-106.3, 95.0-108.3, and 95.7-107.7, respectively. The relative standard deviations varied between 1.5% and 7.3% (n=5). The results showed that the proposed method was a rapid, convenient and feasible method for the determination of SAs in liquid samples. Copyright © 2011 Elsevier B.V. All rights reserved.
Wu, Naijun; Bradley, Ashley C; Welch, Christopher J; Zhang, Li
2012-08-01
Effects of extra-column volume on apparent separation parameters were studied in ultra-high pressure liquid chromatography with columns and inlet connection tubings of various internal diameters (id) using 50-mm long columns packed with 1.8-μm particles under isocratic conditions. The results showed that apparent retention factors were on average 5, 11, 18, and 41% lower than those corrected with extra-column volumes for 4.6-, 3.0-, 2.1-, and 1.0-mm id columns, respectively, when the extra-column volume (11.3 μL) was kept constant. Also, apparent pressures were 31, 16, 12, and 10% higher than those corrected with pressures from extra-column volumes for 4.6-, 3.0-, 2.1-, and 1.0-mm id columns at the respective optimum flow rate for a typical ultra-high pressure liquid chromatography system. The loss in apparent efficiency increased dramatically from 4.6- to 3.0- to 2.1- to 1.0-mm id columns, less significantly as retention factors increased. The column efficiency was significantly improved as the inlet tubing id was decreased for a given column. The results suggest that maximum ratio of extra-column volume to column void volume should be approximately 1:10 for column porosity more than 0.6 and a retention factor more than 5, where 80% or higher of theoretically predicted efficiency could be achieved. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Serrating Nozzle Surfaces for Complete Transfer of Droplets
NASA Technical Reports Server (NTRS)
Kim, Chang-Jin " CJ"
2010-01-01
A method of ensuring the complete transfer of liquid droplets from nozzles in microfluidic devices to nearby surfaces involves relatively simple geometric modification of the nozzle surfaces. The method is especially applicable to nozzles in print heads and similar devices required to dispense liquid droplets having precise volumes. Examples of such devices include heads for soft printing of ink on paper and heads for depositing droplets of deoxyribonucleic acid (DNA) or protein solutions on glass plates to form microarrays of spots for analysis. The main purpose served by the present method is to ensure that droplets transferred from a nozzle have consistent volume, as needed to ensure accuracy in microarray analysis or consistent appearance of printed text and images. In soft printing, droplets having consistent volume are generated inside a print head, but in the absence of the present method, the consistency is lost in printing because after each printing action (in which a drop is ejected from a nozzle), a small residual volume of liquid remains attached to the nozzle. By providing for complete transfer of droplets (and thus eliminating residual liquid attached to the nozzle) the method ensures consistency of volume of transferred droplets. An additional benefit of elimination of residue is prevention of cross-contamination among different liquids printed through the same nozzle a major consideration in DNA microarray analysis. The method also accelerates the printing process by minimizing the need to clean a printing head to prevent cross-contamination. Soft printing involves a hydrophobic nozzle surface and a hydrophilic print surface. When the two surfaces are brought into proximity such that a droplet in the nozzle makes contact with the print surface, a substantial portion of the droplet becomes transferred to the print surface. Then as the nozzle and the print surface are pulled apart, the droplet is pulled apart and most of the droplet remains on the print surface. The basic principle of the present method is to reduce the liquid-solid surface energy of the nozzle to a level sufficiently below the intrinsic solid-liquid surface energy of the nozzle material so that the droplet is not pulled apart and, instead, the entire droplet volume becomes transferred to the print surface. In this method, the liquid-solid surface energy is reduced by introducing artificial surface roughness in the form of micromachined serrations on the inner nozzle surface (see figure). The method was tested in experiments on soft printing of DNA solutions and of deionized water through 0.5-mm-diameter nozzles, of which some were not serrated, some were partially serrated, and some were fully serrated. In the nozzles without serrations, transfer was incomplete; that is, residual liquids remained in the nozzles after printing. However, in every nozzle in which at least half the inner surface was serrated, complete transfer of droplets to the print surface was achieved.
Fractional Consumption of Liquid Hydrogen and Liquid Oxygen During the Space Shuttle Program
NASA Technical Reports Server (NTRS)
Partridge, Jonathan K.
2011-01-01
The Space Shuttle uses the propellants, liquid hydrogen and liquid oxygen, to meet part of the propulsion requirements from ground to orbit. The Kennedy Space Center procured over 25 million kilograms of liquid hydrogen and over 250 million kilograms of liquid oxygen during the 3D-year Space Shuttle Program. Because of the cryogenic nature of the propellants, approximately 55% of the total purchased liquid hydrogen and 30% of the total purchased liquid oxygen were used in the Space Shuttle Main Engines. The balance of the propellants were vaporized during operations for various purposes. This paper dissects the total consumption of liqUid hydrogen and liqUid oxygen and determines the fraction attributable to each of the various processing and launch operations that occurred during the entire Space Shuttle Program at the Kennedy Space Center.
Liquid rocket booster integration study. Volume 1: Executive summary
NASA Technical Reports Server (NTRS)
1988-01-01
The impacts of introducing liquid rocket booster engines (LRB) into the Space Transportation System (STS)/Kennedy Space Center (KSC) launch environment are identified and evaluated. Proposed ground systems configurations are presented along with a launch site requirements summary. Prelaunch processing scenarios are described and the required facility modifications and new facility requirements are analyzed. Flight vehicle design recommendations to enhance launch processing are discussed. Processing approaches to integrate LRB with existing STS launch operations are evaluated. The key features and significance of launch site transition to a new STS configuration in parallel with ongoing launch activities are enumerated. This volume is the executive summary of the five volume series.
Liquid rocket booster integration study. Volume 5, part 1: Appendices
NASA Technical Reports Server (NTRS)
1988-01-01
The impacts of introducing liquid rocket booster engines (LRB) into the Space Transportation System (STS)/Kennedy Space Center (KSC) launch environment are identified and evaluated. Proposed ground systems configurations are presented along with a launch site requirements summary. Prelaunch processing scenarios are described and the required facility modifications and new facility requirements are analyzed. Flight vehicle design recommendations to enhance launch processing are discussed. Processing approaches to integrate LRB with existing STS launch operations are evaluated. The key features and significance of launch site transition to a new STS configuration in parallel with ongoing launch activities are enumerated. This volume is the appendices of the five volume series.
Liquid Rocket Booster Integration Study. Volume 2: Study synopsis
NASA Technical Reports Server (NTRS)
1988-01-01
The impacts of introducing liquid rocket booster engines (LRB) into the Space Transportation System (STS)/Kennedy Space Center (KSC) launch environment are identified and evaluated. Proposed ground systems configurations are presented along with a launch site requirements summary. Prelaunch processing scenarios are described and the required facility modifications and new facility requirements are analyzed. Flight vehicle design recommendations to enhance launch processing are discussed. Processing approaches to integrate LRB with existing STS launch operations are evaluated. The key features and significance of launch site transition to a new STS configuration in parallel with ongoing launch activities are enumerated. This volume is the study summary of the five volume series.
JANNAF 36th Combustion Subcommittee Meeting. Volume 2
NASA Technical Reports Server (NTRS)
Fry, Ronald S. (Editor); Gannaway, Mary T. (Editor)
1999-01-01
Volume 11, the second of three volumes is a compilation of 33 unclassified/unlimited-distribution technical papers presented at the Joint Army-Navy-NASA-Air Force (JANNAF) 36th Combustion Subcommittee held jointly with the 24 Airbreathing Propulsion Subcommittee and 18th Propulsion Systems Hazards Subcommittee. The meeting was held on 18-21 October 1999 at NASA Kennedy Space Center and The DoubleTree Oceanfront Hotel, Cocoa Beach, Florida. Topics covered include gun solid propellant ignition and combustion, Electrothermal Chemical (ETC) propulsion phenomena, liquid propellant gun combustion and barrel erosion, gas phase propellant combustion, kinetic and decomposition phenomena and liquid and hybrid propellant combustion behavior.
Tejada-Casado, Carmen; Lara, Francisco J; García-Campaña, Ana M; Del Olmo-Iruela, Monsalud
2018-03-30
Ultra-high performance liquid chromatography (UHPLC) coupled with fluorescence detection (FL) has been proposed for the first time to determine thirteen benzimidazoles (BZs) in farmed fish samples. In order to optimize the chromatographic separation, parameters such as mobile phase composition and flow rate were carefully studied, establishing a gradient mode with a mobile phase consisted of water (solvent A) and acetonitrile (solvent B) at a flow rate of 0.4 mL/min. The separation was performed on a Zorbax Eclipse Plus RRHD C 18 column (50 × 2.1 mm, 1.8 μm), involving a total analysis time lower than 12 min. Salting-out assisted liquid-liquid extraction (SALLE) was applied as sample treatment to different types of farmed fish (trout, sea bream and sea bass). To obtain satisfactory extraction efficiencies for the studied analytes, several parameters affecting the SALLE procedure were optimized including the amount of sample, type and volume of the extraction solvent, and the nature and amount of the salt used. Characterization of the method in terms of performance characteristics was carried out, obtaining satisfactory results for the linearity (R 2 ≥ 0.997), repeatability (RSD ≤ 6.1%), reproducibility (RSD ≤ 10.8%) and recoveries (R ≥ 79%; RSD ≤ 7.8%). Detection limits between 0.04-29.9 μg kg -1 were obtained, demonstrating the applicability of this fast, simple and environmentally friendly method. Copyright © 2018 Elsevier B.V. All rights reserved.
Laser Processed Heat Exchangers
NASA Technical Reports Server (NTRS)
Hansen, Scott
2017-01-01
The Laser Processed Heat Exchanger project will investigate the use of laser processed surfaces to reduce mass and volume in liquid/liquid heat exchangers as well as the replacement of the harmful and problematic coatings of the Condensing Heat Exchangers (CHX). For this project, two scale unit test articles will be designed, manufactured, and tested. These two units are a high efficiency liquid/liquid HX and a high reliability CHX.
Surface Tension Confines Cryogenic Liquid
NASA Technical Reports Server (NTRS)
Castles, Stephen H.; Schein, Michael E.
1989-01-01
New type of Dewar provides passive, constant-temperature cryogenic cooling for scientific instruments under normal-to low-gravity conditions. Known as Surface-Tension-Contained Liquid Cryogen Cooler (STCLCC), keeps liquid cryogen in known location inside the Dewar by trapping liquid inside spongelike material. Unique sponge material fills most of volume of inner tank. Sponge is all-silica, open-cell material similar to that used for Space Shuttle thermal-protection tiles.
NASA Astrophysics Data System (ADS)
Weger, Lukas; Hoffmann-Jacobsen, Kerstin
2017-09-01
Fluorescence correlation spectroscopy (FCS) measures fluctuations in a (sub-)femtoliter volume to analyze the diffusive behavior of fluorescent particles. This highly sensitive method has proven to be useful for the analysis of dynamic biological systems as well as in chemistry, physics, and material sciences. It is routinely performed with commercial fluorescence microscopes, which provide a confined observation volume by the confocal technique. The evanescent wave of total internal reflectance (TIR) is used in home-built systems to permit a surface sensitive FCS analysis. We present a combined confocal and TIR-FCS setup which uses economic low-power pulsed diode lasers for excitation. Excitation and detection are coupled to time-correlated photon counting hardware. This allows simultaneous fluorescence lifetime and FCS measurements in a surface-sensitive mode. Moreover, the setup supports fluorescence lifetime correlation spectroscopy at surfaces. The excitation can be easily switched between TIR and epi-illumination to compare the surface properties with those in liquid bulk. The capabilities of the presented setup are demonstrated by measuring the diffusion coefficients of a free dye molecule, a labeled polyethylene glycol, and a fluorescent nanoparticle in confocal as well as in TIR-FCS.
The influence of trading volume on market efficiency: The DCCA approach
NASA Astrophysics Data System (ADS)
Sukpitak, Jessada; Hengpunya, Varagorn
2016-09-01
For a single market, the cross-correlation between market efficiency and trading volume, which is an indicator of market liquidity, is attentively analysed. The study begins with creating time series of market efficiency by applying time-varying Hurst exponent with one year sliding window to daily closing prices. The time series of trading volume corresponding to the same time period used for the market efficiency is derived from one year moving average of daily trading volume. Subsequently, the detrended cross-correlation coefficient is employed to quantify the degree of cross-correlation between the two time series. It was found that values of cross-correlation coefficient of all considered stock markets are close to 0 and are clearly out of range in which correlation being considered significant in almost every time scale. Obtained results show that the market liquidity in term of trading volume hardly has effect on the market efficiency.
System and method for liquid silicon containment
Cliber, James A; Clark, Roger F; Stoddard, Nathan G; Von Dollen, Paul
2013-05-28
This invention relates to a system and a method for liquid silicon containment, such as during the casting of high purity silicon used in solar cells or solar modules. The containment apparatus includes a shielding member adapted to prevent breaching molten silicon from contacting structural elements or cooling elements of a casting device, and a volume adapted to hold a quantity of breaching molten silicon with the volume formed by a bottom and one or more sides.
System and method for liquid silicon containment
Cliber, James A; Clark, Roger F; Stoddard, Nathan G; Von Dollen, Paul
2014-06-03
This invention relates to a system and a method for liquid silicon containment, such as during the casting of high purity silicon used in solar cells or solar modules. The containment apparatus includes a shielding ember adapted to prevent breaching molten silicon from contacting structural elements or cooling elements of a casting device, and a volume adapted to hold a quantity of breaching molten silicon with the volume formed by a bottom and one or more sides.
Nanoparticle enhanced ionic liquid heat transfer fluids
Fox, Elise B.; Visser, Ann E.; Bridges, Nicholas J.; Gray, Joshua R.; Garcia-Diaz, Brenda L.
2014-08-12
A heat transfer fluid created from nanoparticles that are dispersed into an ionic liquid is provided. Small volumes of nanoparticles are created from e.g., metals or metal oxides and/or alloys of such materials are dispersed into ionic liquids to create a heat transfer fluid. The nanoparticles can be dispersed directly into the ionic liquid during nanoparticle formation or the nanoparticles can be formed and then, in a subsequent step, dispersed into the ionic liquid using e.g., agitation.
NASA Astrophysics Data System (ADS)
Suchomel, Eric J.; Ramsburg, C. Andrew; Pennell, Kurt D.
2007-12-01
The ability of two biodegradable surfactants, polyoxyethylene (20) sorbitan monooleate (Tween® 80) and sodium dihexyl sulfosuccinate (Aerosol® MA), to recover a representative dense non-aqueous-phase liquid (DNAPL), trichloroethene (TCE), from heterogeneous porous media was evaluated through a combination of batch and aquifer cell experiments. An aqueous solution containing 3.3% Aerosol MA, 8% 2-propanol and 6 g/l CaCl 2 yielded a weight solubilization ratio (WSR) of 1.21 g TCE/g surfactant, with a corresponding liquid-liquid interfacial tension (IFT) of 0.19 dyn/cm. Flushing of aquifer cells containing a TCE-DNAPL source zone with approximately two pore volumes of the AMA formulation resulted in substantial (> 30%) mobilization of TCE-DNAPL. However, a TCE mass recovery of 81% was achieved when the aqueous-phase flow rate was sufficient to displace the mobile TCE-DNAPL toward the effluent well. Aqueous solutions of Tween 80 exhibited a greater capacity to solubilize TCE (WSR = 1.74 g TCE/g surfactant) and exerted markedly less reduction in IFT (10.4 dyn/cm). These data contradict an accepted empirical correlation used to estimate IFT values from solubilization capacity, and indicate a unique capacity of T80 to form concentrated TCE emulsions. Flushing of aquifer cells with less than 2.5 pore volumes of a 4% T80 solution achieved TCE mass recoveries ranging from 66 to 85%, with only slight TCE-DNAPL mobilization (< 5%) occurring when the total trapping number exceeded 2 × 10 - 5 . These findings demonstrate the ability of Tween 80 and Aerosol MA solutions to efficiently recover TCE from a heterogeneous DNAPL source zone, and the utility of the total trapping number as a design parameter for a priori prediction of DNAPL mobilization and bank angle formation when flushing with low-IFT solutions. Given their potential to stimulate microbial reductive dechlorination at low concentrations, these surfactants are well-suited for remedial action plans that couple aggressive mass removal followed by enhanced bioremediation to treat chlorinated solvent source zones.
NASA Astrophysics Data System (ADS)
Deleer, B. G. M.
1981-11-01
Based on population balance, CSD behavior as a function of geometrical and operating variables was studied, using a crystallizer. A potash alum-water system, involving a separation technique which uses surface active agents and an apolar, organic liquid to separate potash alum crystals from mother liquid under the influence of gravity was used to check experimental findings against literature data. Results show action of annular settling spaces is strongly influenced by fluid velocities perpendicular to those directed upwards. The well-mixed volume decreases with increasing crystallizer size until a minimum effective volume is reached. As supersaturation is constant throughout the crystallizer volume under stationary operating conditions, the annular settling space behaves like a growth chamber for crystals in its volume. Swirl in the lower part of the annular volume introduces significant back mixing. Crystals within this space either grow and return to the well-mixed part, or withdraw from the annular volume permanently.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-06
... Volume Requirement in All Assigned SLP Securities and Amend the Exchange's Price List To Specify the... Liquidity Provider (``SLP'') monthly volume requirement in all assigned SLP securities (``monthly volume... existing SLP monthly volume requirement from an ADV of more than 10 million shares to an ADV that is a...
Investigation of Reaction Mechanism on the Lime-Free Roasting of Chromium-Containing Slag
NASA Astrophysics Data System (ADS)
Yu, Kai-ping; Zhang, Hong-ling; Chen, Bo; Xu, Hong-bin; Zhang, Yi
2015-12-01
The lime-free roasting process of trivalent chromium-containing slag was investigated. The effect of Fe and liquid phase on the conversion reaction of chromium was discussed. The oxidation of trivalent chromium depends greatly on the diffusion of Na+ and O2. Both the raw material Na2CO3 and the intermediate product NaFeO2 serve as the carriers of Na+. The Na+ diffusion is improved by the binary liquid phase of Na2CrO4-Na2CO3, whereas excess liquid phase results in a low conversion rate of chromium by hindering the diffusion of oxygen towards the reaction interface. With the increasing of liquid volume, the controlled step of chromium oxidation changes from Na+ diffusion to oxygen diffusion. The mechanism study showed that the volume of liquid phase increased while raising the reaction temperature or prolonging the reaction time. Based on the role of both liquid phase and Fe, the oxidation process of chromium was summarized as a three-stage model: the Na+ diffusion-controlled stage, the O2 diffusion-controlled stage, and the oxidation reaction halted stage.
Liquid crystal films as on-demand, variable thickness (50–5000 nm) targets for intense lasers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poole, P. L., E-mail: poole.134@osu.edu; Andereck, C. D.; Schumacher, D. W.
2014-06-15
We have developed a new type of target for intense laser-matter experiments that offers significant advantages over those currently in use. The targets consist of a liquid crystal film freely suspended within a metal frame. They can be formed rapidly on-demand with thicknesses ranging from nanometers to micrometers, where the particular value is determined by the liquid crystal temperature and initial volume as well as by the frame geometry. The liquid crystal used for this work, 8CB (4′-octyl-4-cyanobiphenyl), has a vapor pressure below 10{sup −6} Torr, so films made at atmospheric pressure maintain their initial thickness after pumping to high vacuum.more » Additionally, the volume per film is such that each target costs significantly less than one cent to produce. The mechanism of film formation and relevant physics of liquid crystals are described, as well as ion acceleration data from the first shots on liquid crystal film targets at the Ohio State University Scarlet laser facility.« less
Scale up of diesel oil biodegradation in a baffled roller bioreactor.
Nikakhtari, Hossein; Song, Wanning; Kumar, Pardeep; Nemati, Mehdi; Hill, Gordon A
2010-05-01
Diesel oil is a suitable substance to represent petroleum contamination from accidental spills in operating and transportation facilities. Using a microbial culture enriched from a petroleum contaminated soil, biodegradation of diesel oil was carried out in 2.2, 55, and 220 L roller baffled bioreactors. The effects of bioreactor rotation speed (from 5 to 45 rpm) and liquid loading (from 18% to 73% of total volume) on the biodegradation of diesel oil were studied. In the small scale bioreactor (2.2L), the maximum rotation speed of 45 rpm resulted in the highest biodegradation rate with a first order biodegradation kinetic constant of 0.095 d(-1). In the larger scale bioreactors, rotation speed did not affect the biodegradation rate. Liquid loadings higher than 64% resulted in reduced biodegradation rates in the small scale bioreactor; however, in the larger roller bioreactors liquid loading did not affect the biodegradation rate. Biodegradation of diesel oil at 5 rpm and 73% loading is recommended for operating large scale roller baffled bioreactors. Under these conditions, high diesel oil concentrations up to 50 gL(-1) can be bioremediated at a rate of 1.61 gL(-1)d(-1). Copyright 2010 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Liu, Dan; Li, Gang; Liu, Haiou
2018-01-01
A kind of multi-functional sites metal-organic framework (MOF) composite (MIL-101-IMBr) was successfully prepared by post-synthesis modification of MIL-101 with imidazolium-based ionic liquids. The ionic liquids not only functionalize as basic sites but also provide halide anions, which serve as a nucleophile in cycloaddition reaction. The prepared functional MOF materials were characterized by X-ray diffraction, fourier transform infrared spectroscopy, scanning electron microscopy, energy dispersive spectroscopy, N2 adsorption-desorption and CO2 temperature programmed desorption. The results of fourier transform infrared spectroscopy and energy dispersive spectroscopy show that the MIL-101-IMBr composite was successfully synthesized. The N2 adsorption-desorption results clearly demonstrated that the modified composites still preserve high BET surface area and total pore volume. The composite exhibits high catalytic activity for the cycloaddition of CO2 with epoxides under mild and co-catalyst free conditions. The conversion of propylene oxide was 95.8% and the selectivity of cyclic carbonate was 97.6% under 0.8 MPa at 80 °C for 4 h. Moreover, the catalyst can be used for at least five times.
Radioactive liquid wastes discharged to ground in the 200 Areas during 1976
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mirabella, J.E.
An overall summary is presented giving the radioactive liquid wastes discharged to ground during 1976 and since startup (for both total and decayed depositions) within the Production and Waste Management Division control zone (200 Area plateau). Overall summaries are also presented for 200 East Area and for 200 West Area. The data contain an estimate of the radioactivity discharged to individual ponds, cribs and specific retention sites within the Production and Waste Management Division during 1976 and from startup through December 31, 1976; an estimate of the decayed activities from startup through 1976; the location and reference drawings of eachmore » disposal site; and the usage dates of each disposal site. The estimates for the radioactivity discharged and for decayed activities dicharged from startup through December 31, 1976 are based upon Item 4 of the Bibliography. The volume of liquid discharged to the ponds also includes major nonradioactive streams. The wastes discharged during 1976 to each active disposal site are detailed on a month-to-month basis, along with the monthly maximum concentration and average concentration data. An estimate of the radioactivity discharged to each active site along with the remaining decayed activities is given.« less
Lee, Sang Joon; Kang, Dooho; Lee, Seung Chul; Ha, Young-Ran
2016-02-03
Female mosquitoes transmit various diseases as vectors during liquid-feeding. Identifying the determinants of vector efficiency is a major scientific challenge in establishing strategies against these diseases. Infection rate and transmission efficiency are interconnected with the mosquito-induced liquid-feeding flow as main indexes of vector efficiency. However, the relationship between liquid-feeding characteristics and pathogen remains poorly understood. The liquid-feeding behavior of Aedes togoi and Anopheles sinensis was comparatively investigated in conjunction with vector efficiency via micro-particle image velocimetry. The flow rates and ratio of the ejection volume of Aedes togoi were markedly higher than those of Anophels sinensis. These differences would influence pathogen re-ingestion. Wall shear stresses of these mosquito species were also clearly discriminatory affecting the infective rates of vector-borne diseases. The variations in volume of two pump chambers and diameter of proboscis of these mosquito species were compared to determine the differences in the liquid-feeding process. Liquid-feeding characteristics influence vector efficiency; hence, this study can elucidate the vector efficiency of mosquitoes and the vector-pathogen interactions and contribute to the development of strategies against vector-borne diseases.
NASA Astrophysics Data System (ADS)
Lee, Sang Joon; Kang, Dooho; Lee, Seung Chul; Ha, Young-Ran
2016-02-01
Female mosquitoes transmit various diseases as vectors during liquid-feeding. Identifying the determinants of vector efficiency is a major scientific challenge in establishing strategies against these diseases. Infection rate and transmission efficiency are interconnected with the mosquito-induced liquid-feeding flow as main indexes of vector efficiency. However, the relationship between liquid-feeding characteristics and pathogen remains poorly understood. The liquid-feeding behavior of Aedes togoi and Anopheles sinensis was comparatively investigated in conjunction with vector efficiency via micro-particle image velocimetry. The flow rates and ratio of the ejection volume of Aedes togoi were markedly higher than those of Anophels sinensis. These differences would influence pathogen re-ingestion. Wall shear stresses of these mosquito species were also clearly discriminatory affecting the infective rates of vector-borne diseases. The variations in volume of two pump chambers and diameter of proboscis of these mosquito species were compared to determine the differences in the liquid-feeding process. Liquid-feeding characteristics influence vector efficiency; hence, this study can elucidate the vector efficiency of mosquitoes and the vector-pathogen interactions and contribute to the development of strategies against vector-borne diseases.
Manipulating Liquids With Acoustic Radiation Pressure Phased Arrays
NASA Technical Reports Server (NTRS)
Oeftering, Richard C.
1999-01-01
High-intensity ultrasound waves can produce the effects of "Acoustic Radiation Pressure" (ARP) and "acoustic streaming." These effects can be used to propel liquid flows and to apply forces that can be used to move or manipulate floating objects or liquid surfaces. NASA's interest in ARP includes the remote-control agitation of liquids and the manipulation of bubbles and drops in liquid experiments and propellant systems. A high level of flexibility is attained by using a high-power acoustic phased array to generate, steer, and focus a beam of acoustic waves. This is called an Acoustic Radiation Pressure Phased Array, or ARPPA. In this approach, many acoustic transducer elements emit wavelets that converge into a single beam of sound waves. Electronically coordinating the timing, or "phase shift," of the acoustic waves makes it possible to form a beam with a predefined direction and focus. Therefore, a user can direct the ARP force at almost any desired point within a liquid volume. ARPPA lets experimenters manipulate objects anywhere in a test volume. This flexibility allow it to be used for multiple purposes, such as to agitate liquids, deploy and manipulate drops or bubbles, and even suppress sloshing in spacecraft propellant tanks.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-18
... rebate of $0.0030 per share for adding liquidity that is 20% or less than NYSE's total intraday adding... that month that exceeds 20% of NYSE's total intraday adding liquidity. For the purposes of paying the DMM rebate, the NYSE total intraday adding liquidity will be totaled monthly \\6\\ and will include all...
Free volume dependence of an ionic molecular rotor in Fluoroalkylphosphate (FAP) based ionic liquids
NASA Astrophysics Data System (ADS)
Singh, Prabhat K.; Mora, Aruna K.; Nath, Sukhendu
2016-01-01
The emission properties of Thioflavin-T (ThT), a cationic molecular rotor, have been investigated in two fluoroalkylphosphate ([FAP]) anion based ionic liquids, namely, 1-ethyl-3-methylimidazolium tris(pentafluoroethyl)trifluorophosphate and 1-(2-hydroxyethyl)-3-methylimidazolium tris(pentafluoroethyl)trifluorophosphate, over a wide temperature range. The micro-viscosities of ionic liquids around ThT, measured from the emission quantum yield, are found to be quite different from their bulk viscosities. The temperature dependence of the viscosity and the emission quantum yield reveals that, despite the very low shear viscosity of these ILs, the non-radiative torsional relaxation has a strong dependence on the free volume of these [FAP] anion based ILs.
Empty liquid phase of colloidal ellipsoids: the role of shape and interaction anisotropy.
Varga, Szabolcs; Meneses-Júarez, Efrain; Odriozola, Gerardo
2014-04-07
We study the effect of anisotropic excluded volume and attractive interactions on the vapor-liquid phase transition of colloidal ellipsoids. In our model, the hard ellipsoid is embedded into an ellipsoidal well, where both the shape of the hard ellipsoid and that of the added enclosing ellipsoidal well can be varied independently. The bulk properties of these particles are examined by means of a van der Waals type perturbation theory and validated with replica exchange Monte Carlo simulations. It is shown that both the critical volume fraction (ηc) and the critical temperature (Tc) of the vapor-liquid phase transition vanish with increasing shape anisotropy for oblate shapes, while ηc → 0 and Tc ≠ 0 are obtained for very elongated prolate shapes. These results suggest that the chance to stabilize empty liquids (a liquid phase with vanishing density) is higher in suspensions of rod-like colloidal ellipsoids than in those of plate-like ones.
Pleural liquid during hemorrhagic hypotension.
Tresoldi, Claudio; Porta, Cristina; Zocchi, Luciano; Agostoni, Emilio
2007-02-15
The effect of approximately 25% or 35% blood loss (b.l.) on volume, pressure, and protein concentration of pleural liquid has been determined in anesthetized rabbits in lateral or supine posture. Volume and pressure of pleural liquid did not change with 25% b.l. 30 and 60 min after beginning of hemorrhage, and with 35% b.l. at 30 min (bleeding time approximately 10 and 12 min, respectively). With 35% b.l. protein concentration of pleural liquid was 85% greater (P<0.01) than control; moreover, percent albumin was smaller (P<0.05), and percent globulin greater (P<0.05) than control. Decrease in arterial plasma protein concentration, hematocrit, and pH after hemorrhage fit literature data. Ventilation at 15 and 30 min increased (P<0.01) by 16% and 23%, respectively, with 25% b.l., but it did not change with 35% b.l., a condition borderline to survival in anesthetized rabbits without ad hoc treatment. Pleural liquid seems protected against derangements from hemorrhage up to 25% b.l. for periods shorter than 1 h.
Gas volume contents within a container, smart volume instrument
NASA Technical Reports Server (NTRS)
Van Buskirk, Paul D. (Inventor); Kelley, Anthony R. (Inventor)
2008-01-01
A method for determining the volume of an incompressible gas in a system including incompressible substances in a zero-gravity environment. The method includes inducing a volumetric displacement within a container and measuring the resulting pressure change. From this data, the liquid level can be determined.
Corresponding-states laws for protein solutions.
Katsonis, Panagiotis; Brandon, Simon; Vekilov, Peter G
2006-09-07
The solvent around protein molecules in solutions is structured and this structuring introduces a repulsion in the intermolecular interaction potential at intermediate separations. We use Monte Carlo simulations with isotropic, pair-additive systems interacting with such potentials. We test if the liquid-liquid and liquid-solid phase lines in model protein solutions can be predicted from universal curves and a pair of experimentally determined parameters, as done for atomic and colloid materials using several laws of corresponding states. As predictors, we test three properties at the critical point for liquid-liquid separation: temperature, as in the original van der Waals law, the second virial coefficient, and a modified second virial coefficient, all paired with the critical volume fraction. We find that the van der Waals law is best obeyed and appears more general than its original formulation: A single universal curve describes all tested nonconformal isotropic pair-additive systems. Published experimental data for the liquid-liquid equilibrium for several proteins at various conditions follow a single van der Waals curve. For the solid-liquid equilibrium, we find that no single system property serves as its predictor. We go beyond corresponding-states correlations and put forth semiempirical laws, which allow prediction of the critical temperature and volume fraction solely based on the range of attraction of the intermolecular interaction potential.
Supercritical Fluid: Liquid, Gas, Both or Neither? A Different Approach.
ERIC Educational Resources Information Center
Meyer, Edwin F.; Meyer, Thomas P.
1986-01-01
Presents a laboratory experiment which determines critical temperature and density of carbon dioxide. Discusses critical point and provides equations to estimate liquid volume fraction. Analyzes experimental results in terms of variables. (JM)
Azimuthal MHD stirring of metal in vessels with cross-sections of different configuration
NASA Astrophysics Data System (ADS)
Siraev, R. R.; Khripchenko, S. Yu
2017-11-01
Continuous casting of cylindrical ingots from aluminum and preparation of aluminum-based alloys and composites require intensive mixing of liquid metal phase in the crystallization area of the melt. It is evident that the topology of the flow in the liquid phase of an ingot should influence the processes occurring during crystallization. Contemporary continuous casting machines use MHD-stirrers that generate an azimuthal motion in a crystallizer with a warm top of circular cross-section in the presence of rotating magnetic field. The flow of metal in the liquid phase of an ingot is similar to its rotation in a solid state, and transport processes are most intensively carried out in the near near-wall region and near the ingot solidification front, where shear flows are essential. In this work, we consider the possibility of amplifying transport processes in the entire volume of a stirred metal by making the cross-section shape of the warm top of the crystallizer different from a circle. It has been found numerically that the total energy of the flow in a crucible of square cross-section is twice as lower as that in a crucible with circular cross-section at the same inductor current. Turbulent pulsations in the square crucible, as well as in the circular one, are concentrated mainly in the near-wall region. The energy of pulsations in the square crucible also reduces, but the time of stirring of the passive impurity introduced into the volume of the metal is less than in the circular crucible. The effect of MHD stirring on the vertical temperature distribution on the square crucible is higher than in the “round crucible”.
Bledsoe, Sarah; Van Buskirk, Alex; Falconer, R James; Hollon, Andrew; Hoebing, Wendy; Jokic, Sladan
2018-02-01
The effectiveness of barcode-assisted medication preparation (BCMP) technology on detecting oral liquid dose preparation errors. From June 1, 2013, through May 31, 2014, a total of 178,344 oral doses were processed at Children's Mercy, a 301-bed pediatric hospital, through an automated workflow management system. Doses containing errors detected by the system's barcode scanning system or classified as rejected by the pharmacist were further reviewed. Errors intercepted by the barcode-scanning system were classified as (1) expired product, (2) incorrect drug, (3) incorrect concentration, and (4) technological error. Pharmacist-rejected doses were categorized into 6 categories based on the root cause of the preparation error: (1) expired product, (2) incorrect concentration, (3) incorrect drug, (4) incorrect volume, (5) preparation error, and (6) other. Of the 178,344 doses examined, 3,812 (2.1%) errors were detected by either the barcode-assisted scanning system (1.8%, n = 3,291) or a pharmacist (0.3%, n = 521). The 3,291 errors prevented by the barcode-assisted system were classified most commonly as technological error and incorrect drug, followed by incorrect concentration and expired product. Errors detected by pharmacists were also analyzed. These 521 errors were most often classified as incorrect volume, preparation error, expired product, other, incorrect drug, and incorrect concentration. BCMP technology detected errors in 1.8% of pediatric oral liquid medication doses prepared in an automated workflow management system, with errors being most commonly attributed to technological problems or incorrect drugs. Pharmacists rejected an additional 0.3% of studied doses. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Yamada, Tomomi; Mukai, Nobuhiro; Tsuchida, Keiichirou; Hayashi, Kazuko
2015-04-01
Traditionally, perioperative nutritional management centered on fluid therapy, but in recent years, with the spread of enhanced recovery after surgery (ERAS) protocols, the utility of oral rehydration therapy (ORT) has been reported. There are few reports, however, on the safety of using jelly type oral rehydration solutions for ORT. We examined the effects of OS-1 jelly on gastric fluid and investigated its safety. A total of 147 patients (age range, 4-91 years), scheduled for elective surgery at our institution for whom ORT was indicated, were enrolled in this study. If the surgery was scheduled for the morning, patients were given two bottles of 200 g OS-1 jelly during the previous evening meal. If surgery was scheduled for the afternoon, two additional 200 g bottles were given to the patient with the morning meal on the day of surgery. Patients were allowed to drink water until two hours before the surgery. Gastric fluid was aspirated with a gastric tube after anesthesia induction, after which, volume and pH were measured. In all cases, gastric content was aspirated as a liquid, not a jelly. The volume and pH were 11.4 ± 14.6 ml and 2.8 ± 2.2, respectively. No major difference was seen in comparison with the data for OS-1 liquid. No postoperative aspiration pneumonia or reflux of gastric contents at the time of anesthesia induction was seen in any of the patients. From the present findings, if the time of water intake is strictly controlled, preoperative rehydration therapy using jelly-type oral rehydration solution is thought to be safe and comparable to liquid solution regarding its effects on gastric fluid.
Johnson, L A; Aalbers, J G; Willems, C M; Rademaker, J H; Rexroad, C E
1982-01-01
A field trial was conducted on several hundred farms in The Netherlands to compare the fertilizing capacity of boar spermatozoa stored for 1, 2, or 3 d at 18 C in either Kiev or Beltsville liquid extender (BL-1). Two storage volumes (25 and 100 ml) were used. Twelve Dutch Landrace boars, all in routine commercial artificial insemination service, provided the semen in twice-a-week collections. Over an 8-wk period in March and April, 1979, 2,849 sows and gilts were inseminated. Farrowing rates were higher (P less than .0001) with Kiev extender than with BL-1 extender (69.3 vs 60.5%) when semen was used over a 3 d period. The volume at which the semen was extended and stored had no effect on any parameter. Farrowing rate declined significantly when semen stored at 18 C for more than 2 d was used (74.5% vs 64.7% with semen stored for 1 and 3 in Kiev extender; 65.9% vs 52.7% with semen stored for 1 and 3 d in BL-1 extender). The farrowing rate, total number of pigs/litter and live pigs/litter were significantly higher for sows than for gilts inseminated with similar extended semen. On the basis of the results of this trial, Kiev extender appears to be more suitable as a diluent for liquid semen than does BL-1. AI with semen extended and stored for 3 d at 18 C can be expected to result in a lower farrowing rate than AI with semen stored for 1 or 2 d.
Degassifying and mixing apparatus for liquids. [potable water for spacecraft
NASA Technical Reports Server (NTRS)
Yamauchi, S. T. (Inventor)
1983-01-01
An apparatus for degassing a liquid comprises a containment vessel a liquid pump and a header assembly (12) within the containment vessel in a volume above the reservoir of the liquid. The pump draws from this reservoir and outputs to the header assembly, the latter being constructed to return the liquid to the reservoir in the form of a number of stacked, vertically spaced, concentric, conical cascades via orifices. A vacuum source provides a partial vacuum in the containment vessel to enhance the degassing process.
1992-12-01
concentrations of DNT, its degradation intermediate 4-methyl 5- nitrocatechol, and TNT were determined by high pressure liquid chromatography (HPLC...to more cost-effective site characterization and cleanup. Many such studies have been performed using chromatography and/or liquid scintillation...volume set that summarizes the research accomplishments of faculty, graduate student, and high school participants in the 1992 AFOSR Summer Research
Liquid metal fast breeder reactors, 1972--1973
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1974-01-01
Reference to 1467 publications on liquid sodium fast breeder reactors cited in Nuclear Science Abstracts Volume 26 (1972) through Volume 27 (1973 through June) are contained in this citation to provide information on the contents of the document. References are arranged in order by the original NSA abstract number which approximately places them in chronological order. Sequence numbers appear beside each reference, and the personal author index refers to these sequence numbers. The subject index refers to the original abstract numbers. (auth)
Accurate high-speed liquid handling of very small biological samples.
Schober, A; Günther, R; Schwienhorst, A; Döring, M; Lindemann, B F
1993-08-01
Molecular biology techniques require the accurate pipetting of buffers and solutions with volumes in the microliter range. Traditionally, hand-held pipetting devices are used to fulfill these requirements, but many laboratories have also introduced robotic workstations for the handling of liquids. Piston-operated pumps are commonly used in manually as well as automatically operated pipettors. These devices cannot meet the demands for extremely accurate pipetting of very small volumes at the high speed that would be necessary for certain applications (e.g., in sequencing projects with high throughput). In this paper we describe a technique for the accurate microdispensation of biochemically relevant solutions and suspensions with the aid of a piezoelectric transducer. It is suitable for liquids of a viscosity between 0.5 and 500 milliPascals. The obtainable drop sizes range from 5 picoliters to a few nanoliters with up to 10,000 drops per second. Liquids can be dispensed in single or accumulated drops to handle a wide volume range. The system proved to be excellently suitable for the handling of biological samples. It did not show any detectable negative impact on the biological function of dissolved or suspended molecules or particles.
Karadaş, Cennet; Kara, Derya
2017-04-01
A novel, simple, rapid, sensitive, inexpensive and environmentally friendly dispersive liquid-liquid microextraction method based on the solidification of a floating organic drop (DLLME-SFO) was developed for the determination of copper by flame atomic absorption spectrometry (FAAS). N-o-Vanillidine-2-amino-p-cresol was used as a chelating ligand and 1-undecanol was selected as an extraction solvent. The main parameters affecting the performance of DLLME-SFO, such as sample pH, volume of extraction solvent, extraction time, concentration of the chelating ligand, salt effect, centrifugation time and sample volume were investigated and optimized. The effect of interfering ions on the recovery of copper was also examined. Under the optimum conditions, the detection limit (3σ) was 0.93μgL -1 for Cu using a sample volume of 20mL, yielding a preconcentration factor of 20. The proposed method was successfully applied to the determination of Cu in tap, river and seawater, rice flour and black tea samples as well as certified reference materials. Copyright © 2016. Published by Elsevier Ltd.
Hara, Shuuji; Uchiyama, Masanobu; Yoshinari, Masami; Matsumoto, Taichi; Jimi, Shiro; Togawa, Atsushi; Takata, Tohru; Takamatsu, Yasushi
2015-09-01
Linezolid is an antimicrobial agent for the treatment of multiresistant Gram-positive infections. A practical high-performance liquid chromatography method was developed for the determination of linezolid in human plasma and saliva. Linezolid and an internal standard (o-ethoxybenzamide) were extracted from plasma and saliva with ethyl acetate and analyzed on a Capcell Pak C18 MG column with UV detection at 254 nm. The calibration curve was linear through the range 0.5-50 µg/mL using a 200 μL sample volume. The intra- and interday precisions were all <6.44% for plasma and 5.60% for saliva. The accuracies ranged from 98.8 to 110% for both matrices. The mean recoveries of linezolid were 80.8% for plasma and 79.0% for saliva. This method was used to determine the plasma and saliva concentrations of linezolid in healthy volunteers who were orally administered a 600 mg dose of linezolid. Our liquid-liquid extraction procedure is easy and requires a small volume of plasma or saliva (200 μL). This small volume can be advantageous in clinical pharmacokinetic studies, especially if children participate. Copyright © 2015 John Wiley & Sons, Ltd.
Vapor condensation onto a non-volatile liquid drop
DOE Office of Scientific and Technical Information (OSTI.GOV)
Inci, Levent; Bowles, Richard K., E-mail: richard.bowles@usask.ca
2013-12-07
Molecular dynamics simulations of miscible and partially miscible binary Lennard–Jones mixtures are used to study the dynamics and thermodynamics of vapor condensation onto a non-volatile liquid drop in the canonical ensemble. When the system volume is large, the driving force for condensation is low and only a submonolayer of the solvent is adsorbed onto the liquid drop. A small degree of mixing of the solvent phase into the core of the particles occurs for the miscible system. At smaller volumes, complete film formation is observed and the dynamics of film growth are dominated by cluster-cluster coalescence. Mixing into the coremore » of the droplet is also observed for partially miscible systems below an onset volume suggesting the presence of a solubility transition. We also develop a non-volatile liquid drop model, based on the capillarity approximations, that exhibits a solubility transition between small and large drops for partially miscible mixtures and has a hysteresis loop similar to the one observed in the deliquescence of small soluble salt particles. The properties of the model are compared to our simulation results and the model is used to study the formulation of classical nucleation theory for systems with low free energy barriers.« less
Tsai, Chia-Ju; Li, Jih-Heng; Feng, Chia-Hsien
2015-09-04
A novel, simple and quick sample preparation method was developed and used for pre-concentration and extraction of six phenylpropenes, including anethole, estragole, eugenol, methyl eugenol, safrole and myristicin, from oil samples by dual dispersive liquid-liquid microextraction. Gas chromatography-mass spectrometry was used for determination and separation of compounds. Several experimental parameters affecting extraction efficiency were evaluated and optimized, including forward-extractant type and volume, surfactant type and concentration, water volume, and back-extractant type and volume. For all analytes (10-1000ng/mL), the limits of detection (S/N≧3) ranged from 1.0 to 3.0ng/mL; the limits of quantification (S/N≧10) ranged from 2.5 to 10.0ng/mL; and enrichment factors ranged from 3.2 to 37.1 times. Within-run and between-run relative standard deviations (n=6) were less than 2.61% and less than 4.33%, respectively. Linearity was excellent with determination coefficients (r(2)) above 0.9977. The experiments showed that the proposed method is a simple, effective, and environmentally friendly method of analyzing phenylpropenes in oil samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Jejunal pouch with nerve preservation and interposition after total gastrectomy.
Kobayashi, I; Ohwada, S; Ohya, T; Yokomori, T; Iesato, H; Morishita, Y
1998-01-01
In this paper, we describe operative technique details and our results with a modified technique for jejunal pouch formation and interposition after total gastrectomy, with an overall aim to achieve results superior to jejunal pouch and Roux-en-Y reconstruction, as reported in the literature. Following total gastrectomy, the jejunum was divided approximately 20 cm distal to the ligament of Treitz. Marginal vessels were not divided in order to preserve the nerves in the 50 cm of distal jejunum which would be used for pouch construction. The pouch was constructed using a linear stapler (Endo GiA, United States Surgical Corp., Norwalk, Conn). A total of 15 gastric cancer patients underwent construction of a nerve-preserving jejunal pouch and interposition following total gastrectomy. None of the patients experienced postoperative complications due to pouch construction. Additionally, discomforts such as dumping or stagnation were not observed. Mild reflux esophagitis occurred in five of the 15 patients and was resolved by oral administration of camostat mesilate. Six months after surgery, the average patient's diet volume and body weight had gradually increased to 79% and 86%, respectively, of the presurgical levels. A dual phase, dual isotope radionucleid pouch emptying study was also performed six months after surgery. The intra-pouch RI retention rate was 47% for liquid food and 53% for solid food 120 minutes after intake. The emptying rate was slower for both solid and liquid food, as compared with healthy individuals. The pouch-emptying test demonstrated a satisfactory retention capacity and an acceptable emptying time as a gastric substitute. The patients who underwent gastric reconstruction with a nerve-preserving jejunal pouch with interposition have experienced a reasonably good quality of life.
Morado Piñeiro, Andrés; Moreda-Piñeiro, Jorge; Alonso-Rodríguez, Elia; López-Mahía, Purificación; Muniategui-Lorenzo, Soledad; Prada-Rodríguez, Darío
2013-02-15
Analytical methods for the determination of total arsenic and arsenic species (mainly As(III) and As(V)) in human scalp hair have been developed. Inductively coupled plasma-mass spectrometry (ICP-MS) and high performance liquid chromatography (HPLC) coupled to ICP-MS have been used for total arsenic and arsenic species determination, respectively. The proposed methods include a "green", fast, high efficient and automated species leaching procedure by pressurized hot water extraction (PHWE). The operating parameters for PHWE including modifier concentration, extraction temperature, static time, extraction steps, pressure, mean particle size, diatomaceous earth (DE) mass/sample mass ratio and flush volume were studied using design of experiments (Plackett-Burman design PBD). Optimum condition implies a modifier concentration (acetic acid) of 150 mM and powdered hair samples fully mixed with diatomaceous earth (DE) as a dispersing agent at a DE mass/sample mass ratio of 5. The extraction has been carried out at 100°C and at an extraction pressure of 1500 psi for 5 min in four extraction step. Under optimised conditions, limits of quantification of 7.0, 6.3 and 50.3 ng g(-1) for total As, As(III) and As(V), respectively were achieved. Repeatability of the overall procedure (4.4, 7.2 and 2.1% for total As, As(III) and As(V), respectively) was achieved. The analysis of GBW-07601 (human hair) certified reference material was used for validation. The optimised method has been finally applied to several human scalp hair samples. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Moitra, Pranabendu; Gonnermann, Helge
2014-05-01
Magma often contains crystals of various shapes and sizes. We present experimental results on the effect of the shape- and size-distribution of solid particles on the rheological properties of solid-liquid suspensions, which are hydrodynamically analogous to crystal-bearing magmas. The suspensions were comprised of either a single particle shape and size (unimodal) or a mixture of two different particle shapes and sizes (bimodal). For each type of suspension we characterized the dry maximum packing fraction of the particle mixture using the tap density method. We then systematically varied the total volume fraction of particles in the suspension, as well as the relative proportion of the two different particle types in the bimodal suspensions. For each of the resultant mixtures (suspensions) we performed controlled shear stress experiments using a rotational rheometer in parallel-plate geometry spanning 4 orders of magnitude in shear stress. The resultant data curves of shear stress as a function of shear rate were fitted using a Herschel-Bulkley rheological model. We find that the dry maximum packing decreases with increasing particle aspect ratio (ar) and decreasing particle size ratio (Λ). The highest dry maximum packing was obtained at 60-75% volume of larger particles for bimodal spherical particle mixture. Normalized consistency, Kr, defined as the ratio of the consistency of the suspension and the viscosity of the suspending liquid, was fitted using a Krieger-Dougherty model as a function of the total solid volume fraction (φ). The maximum packing fractions (φm) obtained from the shear experimental data fitting of the unimodal suspensions were similar in magnitude with the dry maximum packing fractions of the unimodal particles. Subsequently, we used the dry maximum packing fractions of the bimodal particle mixtures to fit Kr as a function of φ for the bimodal suspensions. We find that Kr increases rapidly for suspensions with larger ar and smaller Λ. We also find that both the apparent yield stress and the shear thinning behavior of the suspensions increase with increasing ar and become significant at φ/φm ≥ 0.4.
Sun, Yanchun; Xu, Xianzhu; Mou, Zhenbo; Wang, Jing; Tan, Zhijun; Wu, Song
2012-12-01
A rapid, sensitive, and reliable ultra-performance liquid chromatography (UPLC) coupled with photodiode array detection method was developed for the amino acid analysis of Amur sturgeon (Acipenser schrenckii Brandt). The method uses minimal sample volume and automated online precolumn derivitization of amino acids with fluorescent 6-aminoquinolyl-carbamyl reagent. The chromatographic separation was achieved by UPLC, which used a column with 1.7 μm particle packing that enabled higher speed of analysis, peak capacity, greater resolution, and increased sensitivity. Amino acid derivatives obtained under optimal conditions were separated on a Waters UPLC BEH C(18) column with Acetonitrile-acetate buffer as mobile phase. Matrix effects were investigated and good linearities with correlation coefficients better than 0.9949 were obtained over a wide range of 5-1000 μmol/L for all amino acids. The simple sample preparation and minimal sample volume make the method useful for the quantitation of 17 amino acids in Amur sturgeon samples. It is concluded that a rapid and robust platform based on UPLC was established, and a total of 17 amino acids of Amur sturgeon were tentatively detected. This method showed good accuracy and repeatability that can be used for the quantification of amino acids in real samples. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Liquid rocket booster integration study. Volume 3: Study products. Part 2: Sections 8-19
NASA Technical Reports Server (NTRS)
1988-01-01
The impacts of introducing liquid rocket booster engines (LRB) into the Space Transportation System (STS)/Kennedy Space Center (KSC) launch environment are identified and evaluated. Proposed ground systems configurations are presented along with a launch site requirements summary. Prelaunch processing scenarios are described and the required facility modifications and new facility requirements are analyzed. Flight vehicle design recommendations to enhance launch processing are discussed. Processing approaches to integrate LRB with existing STS launch operations are evaluated. The key features and significance of launch site transition to a new STS configuration in parallel with ongoing launch activities are enumerated. This volume is part two of the study products section of the five volume series.
NASA Astrophysics Data System (ADS)
Ramanaiah, S.; Rao, C. Narasimha; Nagaraja, P.; Venkateswarlu, P.
2015-11-01
Exces volumes, VE, and excess isentropic compressibilities, κSE, have been reported as a function of composition for binary liquid mixtures of trichloroethylene with ethyl acetate, n-propyl acetate, and n-butyl acetate at 303.15 K. Isentropic compressibilities are calculated using measured sound speeds and density data for pure components and for binary mixtures. Excess volumes and excess isentropic compressibilities are found to be negative for the three systems studied over the entire composition range at 303.15 K, whereas these values become more negative with an increase of carbon chain length. The results are discussed in terms of intermolecular interactions between unlike molecules.
Liquid rocket booster integration study. Volume 3, part 1: Study products
NASA Technical Reports Server (NTRS)
1988-01-01
The impacts of introducing liquid rocket booster engines (LRB) into the Space Transportation System (STS)/Kennedy Space Center (KSC) launch environment are identified and evaluated. Proposed ground systems configurations are presented along with a launch site requirements summary. Prelaunch processing scenarios are described and the required facility modifications and new facility requirements are analyzed. Flight vehicle design recommendations to enhance launch processing are discussed. Processing approaches to integrate LRB with existing STS launch operations are evaluated. The key features and significance of launch site transition to a new STS configuration in parallel with ongoing launch activities are enumerated. This volume is part one of the study products section of the five volume series.
Smolich, Joseph J
2014-02-15
Although a reduction in lung liquid volume increases fetal pulmonary blood flow, the changes in central flow patterns that sustain this increased pulmonary perfusion are unknown. To address this issue, eight anesthetized late-gestation fetal sheep were instrumented with pulmonary trunk (PT), ductus arteriosus (DA), and left pulmonary artery (PA) micromanometer catheters and transit-time flow probes, with blood flow profile and wave intensity analyses performed at baseline and after withdrawal of lung liquid via an endotracheal tube. Reducing lung liquid volume by 19 ± 6 ml/kg (mean ± SD) augmented right ventricular power by 34% (P < 0.001), with distribution of an accompanying increase in mean PT blood flow (245 ± 63 ml/min, P < 0.001) to the lungs (169 ± 91 ml/min, P = 0.001) and across the DA (77 ± 92 ml/min, P = 0.04). However, although PT and DA flow increments were confined to systole and were related to an increased magnitude of flow-increasing, forward-running compression waves, the rise in PA flow spanned both systole (108 ± 66 ml/min) and diastole (61 ± 32 ml/min). Flow profile analysis showed that the step-up in PA diastolic flow was associated with diminished PA diastolic backflow and accompanied by a lesser degree of diastolic right-to-left DA shunting. These data suggest that an increased pulmonary blood flow after reduction of lung liquid volume is associated with substantial changes in PT-DA-PA interactions and underpinned by two main factors: 1) enhanced right ventricular pump function that increases PA systolic inflow and 2) decreased PA diastolic backflow that arises from a fundamental change in PA reservoir function, thereby resulting in greater passage of systolic inflow through the lungs.
Biocompatible ionic liquid-biopolymer electrolyte-enabled thin and compact magnesium-air batteries.
Jia, Xiaoteng; Yang, Yang; Wang, Caiyun; Zhao, Chen; Vijayaraghavan, R; MacFarlane, Douglas R; Forsyth, Maria; Wallace, Gordon G
2014-12-10
With the surge of interest in miniaturized implanted medical devices (IMDs), implantable power sources with small dimensions and biocompatibility are in high demand. Implanted battery/supercapacitor devices are commonly packaged within a case that occupies a large volume, making miniaturization difficult. In this study, we demonstrate a polymer electrolyte-enabled biocompatible magnesium-air battery device with a total thickness of approximately 300 μm. It consists of a biocompatible polypyrrole-para(toluene sulfonic acid) cathode and a bioresorbable magnesium alloy anode. The biocompatible electrolyte used is made of choline nitrate (ionic liquid) embedded in a biopolymer, chitosan. This polymer electrolyte is mechanically robust and offers a high ionic conductivity of 8.9 × 10(-3) S cm(-1). The assembled battery delivers a maximum volumetric power density of 3.9 W L(-1), which is sufficient to drive some types of IMDs, such as cardiac pacemakers or biomonitoring systems. This miniaturized, biocompatible magnesium-air battery may pave the way to a future generation of implantable power sources.
49 CFR 173.150 - Exceptions for Class 3 (flammable and combustible liquids).
Code of Federal Regulations, 2014 CFR
2014-10-01
....11), when transported via motor vehicle, vessel, or rail, is not subject to the requirements of this... containing ethyl alcohol classed as a flammable liquid or flammable solid containing not more than 70% ethyl alcohol by volume for liquids, by weight for solids are excepted from the HMR provided that: (i) For non...
Mora-Castilla, Sergio; To, Cuong; Vaezeslami, Soheila; Morey, Robert; Srinivasan, Srimeenakshi; Dumdie, Jennifer N; Cook-Andersen, Heidi; Jenkins, Joby; Laurent, Louise C
2016-08-01
As the cost of next-generation sequencing has decreased, library preparation costs have become a more significant proportion of the total cost, especially for high-throughput applications such as single-cell RNA profiling. Here, we have applied novel technologies to scale down reaction volumes for library preparation. Our system consisted of in vitro differentiated human embryonic stem cells representing two stages of pancreatic differentiation, for which we prepared multiple biological and technical replicates. We used the Fluidigm (San Francisco, CA) C1 single-cell Autoprep System for single-cell complementary DNA (cDNA) generation and an enzyme-based tagmentation system (Nextera XT; Illumina, San Diego, CA) with a nanoliter liquid handler (mosquito HTS; TTP Labtech, Royston, UK) for library preparation, reducing the reaction volume down to 2 µL and using as little as 20 pg of input cDNA. The resulting sequencing data were bioinformatically analyzed and correlated among the different library reaction volumes. Our results showed that decreasing the reaction volume did not interfere with the quality or the reproducibility of the sequencing data, and the transcriptional data from the scaled-down libraries allowed us to distinguish between single cells. Thus, we have developed a process to enable efficient and cost-effective high-throughput single-cell transcriptome sequencing. © 2016 Society for Laboratory Automation and Screening.
Sagawa, Toshihiko; Tomizawa, Taku; Mizuide, Masafumi; Yasuoka, Hidetoshi; Shimoyama, Yasuyuki; Kakizaki, Satoru; Kawamura, Osamu; Kusano, Motoyasu; Yamada, Masanobu
2015-01-01
Polyethylene glycol- (PEG-) based bowel preparations for colonoscopies are often poorly tolerated due to the large volumes of fluid intake required. We compared low-volume “modified” PEG + ascorbic acid (AJG522) with standard PEG with electrolytes (PEG + E) in addition to a stimulant laxative and an agent to improve bowel function for the bowel cleansing before colonoscopy to evaluate its efficacy, safety, and acceptability. Outpatients scheduled to undergo colonoscopy were randomized to receive either AJG522 or PEG + E. Bowel cleansing conditions were assessed via macroscopic fecal findings by blinded and independent investigators. A survey of the patients' feedback regarding the preparation was conducted by questionnaire. Successful cleansing was achieved in all cases, except for 4 cases in the PEG + E group, at 3 hours after taking the preparation. The fecal properties were significantly clearer in the AJG522 group than in the PEG + E group at 2 hours after taking each preparation (P = 0.013). Although the total liquid volume of the bowel preparation was not reduced, the AJG522 preparation could significantly reduce the required volume of the preparation (P < 0.0001). Moreover, the patients in the AJG522 group had better acceptability (P = 0.010). There were no significant differences in the safety profiles between groups (UMIN000013892). PMID:25688357
Liquid and gaseous oxygen safety review, volume 1
NASA Technical Reports Server (NTRS)
Lapin, A.
1972-01-01
Materials used or contained in liquid and gaseous oxygen systems are analyzed for their compatibility; and areas of possible concern in oxygen systems are outlined. Design criteria, cleaning procedures, and quality control methods are covered in detail.
NASA Astrophysics Data System (ADS)
Lesage, E.; Massol, H.; Schmidt, F.
2018-06-01
This study aims at modeling the cryomagma ascent from a liquid reservoir to Europa's surface. We obtain the eruption duration and emitted cryomagma volume at the surface for different chamber depths and volumes and different cryomagma compositions.
NASA Astrophysics Data System (ADS)
Li, Yong; Peng, Guilong; He, Qiang; Zhu, Hui; Al-Hamadani, Sulala M. Z. F.
2015-04-01
In the present work, a dispersive liquid-liquid microextraction based on the solidification of floating organic drop (DLLME-SFO) combined with inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of Pb, Co, Cu, Ni, Zn. The influences of analytical parameters, including pH, extraction solvent volume, disperser solvent volume, concentration of chelating agent on the quantitative recoveries of Pb, Co, Cu, Ni, Zn were investigated. The effect of the interfering ions on the analytes recovery was also investigated. Under the optimized conditions, the limits of detection were 0.97-2.18 ng L-1. The relative standard deviations (RSDs) were 2.62-4.51% (n = 7, C = 20 ng L-1). The proposed method was successfully applied for the analysis of ultra trace metals in wastewater samples.
Liquidity crisis, granularity of the order book and price fluctuations
NASA Astrophysics Data System (ADS)
Cristelli, M.; Alfi, V.; Pietronero, L.; Zaccaria, A.
2010-01-01
We introduce a microscopic model for the dynamics of the order book to study how the lack of liquidity influences price fluctuations. We use the average density of the stored orders (granularity g) as a proxy for liquidity. This leads to a Price Impact Surface which depends on both volume ω and g. The dependence on the volume (averaged over the granularity) of the Price Impact Surface is found to be a concave power law function <φ(ω,g)>g ˜ ωδ with δ ≈ 0.59. Instead the dependence on the granularity is φ(ω,g|ω) ˜ gα with α ≈ -1, showing a divergence of price fluctuations in the limit g → 0. Moreover, even in intermediate situations of finite liquidity, this effect can be very large and it is a natural candidate for understanding the origin of large price fluctuations.
Pleural liquid and kinetic friction coefficient of mesothelium after mechanical ventilation.
Bodega, Francesca; Sironi, Chiara; Porta, Cristina; Zocchi, Luciano; Agostoni, Emilio
2015-01-15
Volume and protein concentration of pleural liquid in anesthetized rabbits after 1 or 3h of mechanical ventilation, with alveolar pressure equal to atmospheric at end expiration, were compared to those occurring after spontaneous breathing. Moreover, coefficient of kinetic friction between samples of visceral and parietal pleura, obtained after spontaneous or mechanical ventilation, sliding in vitro at physiological velocity under physiological load, was determined. Volume of pleural liquid after mechanical ventilation was similar to that previously found during spontaneous ventilation. This finding is contrary to expectation of Moriondo et al. (2005), based on measurement of lymphatic and interstitial pressure. Protein concentration of pleural liquid after mechanical ventilation was also similar to that occurring after spontaneous ventilation. Coefficient of kinetic friction after mechanical ventilation was 0.023±0.001, similar to that obtained after spontaneous breathing. Copyright © 2014 Elsevier B.V. All rights reserved.
40 CFR Table 4 to Subpart Uuuuu of... - Operating Limits for EGUs
Code of Federal Regulations, 2014 CFR
2014-07-01
...-mercury HAP metals (total HAP metals, for liquid oil-fired units), or individual non-mercury HAP metals... demonstrating compliance with the filterable PM, total non-mercury HAP metals (total HAP metals, for liquid oil-fired units), or individual non-mercury HAP metals (individual HAP metals including Hg, for liquid oil...
40 CFR Table 4 to Subpart Uuuuu of... - Operating Limits for EGUs
Code of Federal Regulations, 2013 CFR
2013-07-01
...-mercury HAP metals (total HAP metals, for liquid oil-fired units), or individual non-mercury HAP metals... demonstrating compliance with the filterable PM, total non-mercury HAP metals (total HAP metals, for liquid oil-fired units), or individual non-mercury HAP metals (individual HAP metals including Hg, for liquid oil...
Laforge, François O; Carpino, James; Rotenberg, Susan A; Mirkin, Michael V
2007-07-17
The ability to manipulate ultrasmall volumes of liquids is essential in such diverse fields as cell biology, microfluidics, capillary chromatography, and nanolithography. In cell biology, it is often necessary to inject material of high molecular weight (e.g., DNA, proteins) into living cells because their membranes are impermeable to such molecules. All techniques currently used for microinjection are plagued by two common problems: the relatively large injector size and volume of injected fluid, and poor control of the amount of injected material. Here we demonstrate the possibility of electrochemical control of the fluid motion that allows one to sample and dispense attoliter-to-picoliter (10(-18) to 10(-12) liter) volumes of either aqueous or nonaqueous solutions. By changing the voltage applied across the liquid/liquid interface, one can produce a sufficient force to draw solution inside a nanopipette and then inject it into an immobilized biological cell. A high success rate was achieved in injections of fluorescent dyes into cultured human breast cells. The injection of femtoliter-range volumes can be monitored by video microscopy, and current/resistance-based approaches can be used to control injections from very small pipettes. Other potential applications of the electrochemical syringe include fluid dispensing in nanolithography and pumping in microfluidic systems.
Laforge, François O.; Carpino, James; Rotenberg, Susan A.; Mirkin, Michael V.
2007-01-01
The ability to manipulate ultrasmall volumes of liquids is essential in such diverse fields as cell biology, microfluidics, capillary chromatography, and nanolithography. In cell biology, it is often necessary to inject material of high molecular weight (e.g., DNA, proteins) into living cells because their membranes are impermeable to such molecules. All techniques currently used for microinjection are plagued by two common problems: the relatively large injector size and volume of injected fluid, and poor control of the amount of injected material. Here we demonstrate the possibility of electrochemical control of the fluid motion that allows one to sample and dispense attoliter-to-picoliter (10−18 to 10−12 liter) volumes of either aqueous or nonaqueous solutions. By changing the voltage applied across the liquid/liquid interface, one can produce a sufficient force to draw solution inside a nanopipette and then inject it into an immobilized biological cell. A high success rate was achieved in injections of fluorescent dyes into cultured human breast cells. The injection of femtoliter-range volumes can be monitored by video microscopy, and current/resistance-based approaches can be used to control injections from very small pipettes. Other potential applications of the electrochemical syringe include fluid dispensing in nanolithography and pumping in microfluidic systems. PMID:17620612
The impact of information disclosure on market liquidity: Evidence from firms' use of Twitter
NASA Astrophysics Data System (ADS)
Qu, Qixing; Wang, Lin; Qin, Liangjuan; Zhao, Xiaoye; Wang, Lijie
2017-01-01
Despite the popular use of social media by firms, empirical research investigating their economic values still lags. Based on the Security Exchange Commission's (SEC) new regulation on Fair Disclosure valid important corporate information discloses via social media (RIDSM), in this study, we examine the effectiveness of this new regulation to market liquidity. We collect trade data including daily volume and bid-ask spread to assemble a unique data set at individual firm level from S&P 500 firms and analyze the firms' bid-ask spread and volume before and after issuing the regulation. This natural experiment allows us to separate the effect of regulation from the effect of other confounding factors. The results from our panel data analyses indicate that bid-ask spread has decreased by about 5% in response to the new regulation. Our results are statistically significant and highly robust. We also examine the impact of the new regulation on a volume-based measure of liquidity, and find that the regulation is associated with greater volume, consistent with a reduction in information asymmetry. Moreover, this result holds mainly for firms that are high-tech, consistent with them being in greater need of this additional information disclosure channel.
Comparative drug release measurements in limited amounts of liquid: a suppository formulation study.
Welch, Ken; Ek, Ragnar; Strømme, Maria
2006-07-01
A novel method for the investigation of drug formulations in limited liquid volumes is presented. The experimental setup consists of a measurement cell containing an absorbent sponge cloth placed between two parallel electrodes. Conductivity measurements are used to monitor the drug release from the dosage form. By varying the amount of water contained in the absorbent cloth surrounding the dosage form, it is possible to measure the drug release performance of the dosage form in very limited amounts of water. The method was employed to test four different tablet formulations consisting of the model drug NaCl incorporated in excipient matrices of hard fat, polyethylene glycol, microcrystalline cellulose and a mixture of microcrystalline cellulose and croscarmellose sodium (Ac-Di-Sol). The drug release rates of the different formulations in limited water volumes differed markedly from the release rates in an excess of water. Whereas the release rates from all tablet types in an excess of water showed only minor differences among the tablet types, the release rates from the tablets formulated with disintegrating excipients were clearly superior in limited water volumes. The developed method for drug release in limited volumes of liquid should be suitable for evaluation of rectal dosage forms.
Ginosar, Daniel M.; Wendt, Daniel S.; Petkovic, Lucia M.
2014-06-10
A method of removing a nonpolar solvent from a fluid volume that includes at least one nonpolar compound, such as a fat, an oil or a triglyceride, is provided. The method comprises contacting a fluid volume with an expanding gas to expand the nonpolar solvent and form a gas-expanded solvent. The gas-expanded solvent may have a substantially reduced density in comparison to the at least one nonpolar compound and/or a substantially reduced capacity to solubilize the nonpolar compound, causing the nonpolar compounds to separate from the gas-expanded nonpolar solvent into a separate liquid phase. The liquid phase including the at least one nonpolar compound may be separated from the gas-expanded solvent using conventional techniques. After separation of the liquid phase, at least one of the temperature and pressure may be reduced to separate the nonpolar solvent from the expanding gas such that the nonpolar solvent may be recovered and reused.
Extraction of anionic dye from aqueous solutions by emulsion liquid membrane.
Dâas, Attef; Hamdaoui, Oualid
2010-06-15
In this work, the extraction of Congo red (CR), an anionic disazo direct dye, from aqueous solutions by emulsion liquid membrane (ELM) was investigated. The important operational parameters governing emulsion stability and extraction behavior of dye were studied. The extraction of CR was influenced by a number of variables such as surfactant concentration, stirring speed, acid concentration in the feed solution and volume ratios of internal phase to organic phase and of emulsion to feed solution. Under most favorable conditions, practically all the CR molecules present in the feed phase were extracted even in the presence of salt (NaCl). At the optimum experimental conditions, total removal of antharaquinonic dye Acid Blue 25 was attained after only 10 min. Influence of sodium carbonate concentration as internal receiving phase on the stripping efficiency of CR was examined. The best sodium carbonate concentration in the internal phase that conducted to excellent stripping efficiency (>99%) and emulsion stability was 0.1N. The membrane recovery was total and the permeation of CR was not decreased up to seven runs. ELM process is a promising alternative to conventional methods and should increase awareness of the potential for recovery of anionic dyes. Copyright 2010 Elsevier B.V. All rights reserved.
Freeze concentration for enrichment of nutrients in yellow water from no-mix toilets.
Gulyas, H; Bruhn, P; Furmanska, M; Hartrampf, K; Kot, K; Lüttenberg, B; Mahmood, Z; Stelmaszewska, K; Otterpohl, R
2004-01-01
Separately collected urine ("yellow water") can be utilized as fertilizer. In order to decrease storage volumes and energy consumption for yellow water transport to fields, enrichment of nutrients in yellow water has to be considered. Laboratory-scale batch freeze concentration of yellow water has been tested in ice-front freezing apparatus: a stirred vessel and a falling film freeze concentrator (coolant temperatures: -6 to -16 degrees C). With progressing enrichment of the liquid concentrate, the frozen ice was increasingly contaminated with yellow water constituents (ammonia, total nitrogen, total phosphorus, TOC, and salts determined as conductivity). The higher the initial salinity of the yellow water and the lower the mechanical agitation of the liquid phase contacting the growing ice front, the more the frozen ice was contaminated. The results indicate, that in ice-front freezing devices multistage processes are necessary, i.e. the melted ice phase has to be purified (and the concentrates must be further enriched) in a second or even in a third stage. Energy consumption of this process is very high. However, technical scale suspension freeze concentration is reasonable in centralized ecological sanitation schemes if the population exceeds 0.5 million and distance of yellow water transportation to fields is more than 80 km.
KuKanich, B; Coetzee, J F; Gehring, R; Hubin, M
2007-08-01
The purpose of the study was to compare the disposition of pharmacologic markers for cytochrome P-450 (CYP) metabolism, glomerular filtration rate (GFR), and extracellular (ECFV) and total body fluid volumes (TBFV) of Greyhounds and Beagles. Six healthy Greyhound and six healthy Beagle dogs were studied. Antipyrine, a marker for CYP metabolism and TBFV, and inulin, a marker for the GFR and ECFV, were administered i.v. Samples were collected at predetermined times and plasma was analyzed by validated high-pressure liquid chromatography (HPLC) methods. There were no differences in the disposition or pharmacokinetic parameters for inulin between the dog breeds. However, the clearance of antipyrine (mean = 8.33 mL/min/kg) in Greyhounds was significantly slower than Beagles (13.42 mL/min/kg, P = 0.004). The volume of distribution of antipyrine was significantly larger in Greyhounds (0.789 L/kg) than in Beagles (0.644 L/kg, P = 0.01). The half-life of antipyrine was significantly longer in Greyhounds (1.09 h) compared with Beagles (0.55 h, P = 0.002). The in vitro plasma protein binding of antipyrine was significantly less in Greyhounds (28%) compared with Beagles (40.3%, P = 0.008). Greyhounds exhibited significantly slower CYP metabolism, higher TBFV, and lower in vitro protein binding of antipyrine compared with Beagles. No differences in GFR or ECFV were found.
Maximum magnitude earthquakes induced by fluid injection
McGarr, Arthur F.
2014-01-01
Analysis of numerous case histories of earthquake sequences induced by fluid injection at depth reveals that the maximum magnitude appears to be limited according to the total volume of fluid injected. Similarly, the maximum seismic moment seems to have an upper bound proportional to the total volume of injected fluid. Activities involving fluid injection include (1) hydraulic fracturing of shale formations or coal seams to extract gas and oil, (2) disposal of wastewater from these gas and oil activities by injection into deep aquifers, and (3) the development of enhanced geothermal systems by injecting water into hot, low-permeability rock. Of these three operations, wastewater disposal is observed to be associated with the largest earthquakes, with maximum magnitudes sometimes exceeding 5. To estimate the maximum earthquake that could be induced by a given fluid injection project, the rock mass is assumed to be fully saturated, brittle, to respond to injection with a sequence of earthquakes localized to the region weakened by the pore pressure increase of the injection operation and to have a Gutenberg-Richter magnitude distribution with a b value of 1. If these assumptions correctly describe the circumstances of the largest earthquake, then the maximum seismic moment is limited to the volume of injected liquid times the modulus of rigidity. Observations from the available case histories of earthquakes induced by fluid injection are consistent with this bound on seismic moment. In view of the uncertainties in this analysis, however, this should not be regarded as an absolute physical limit.
Rodríguez, Rogelio; Avivar, Jessica; Ferrer, Laura; Leal, Luz O; Cerdà, Victor
2012-07-15
A novel lab-on-valve system has been developed for strontium determination in environmental samples. Miniaturized lab-on-valve system potentially offers facilities to allow any kind of chemical and physical processes, including fluidic and microcarrier bead control, homogenous reaction and liquid-solid interaction. A rapid, inexpensive and fully automated method for the separation and preconcentration of total and radioactive strontium, using a solid phase extraction material (Sr-Resin), has been developed. Total strontium concentrations are determined by ICP-OES and (90)Sr activities by a low background proportional counter. The method has been successfully applied to different water samples of environmental interest. The proposed system offers minimization of sample handling, drastic reduction of reagent volume, improvement of the reproducibility and sample throughput and attains a significant decrease of both time and cost per analysis. The LLD of the total Sr reached is 1.8ng and the minimum detectable activity for (90)Sr is 0.008Bq. The repeatability of the separation procedure is 1.2% (n=10). Copyright © 2011 Elsevier B.V. All rights reserved.
Compatibility of 5-fluorouracil and total parenteral nutrition solutions.
Hardin, T C; Clibon, U; Page, C P; Cruz, A B
1982-01-01
The physicochemical stability and availability of 0.1% 5-fluorouracil solutions in D5W and a typical total parenteral nutrition solution (hypertonic dextrose and crystalline amino acids) were studied in both glass and Viaflex delivery systems. Serial samples collected over a 48-hour period were assayed for 5-fluorouracil concentration using a high performance liquid chromatographic technique. Changes in the pH as well as precipitate formation were also investigated. There was no reduction in the amount of 5-fluorouracil at 48 hours in either the glass or plastic system, regardless of whether the drug was added to D5W or to the total parenteral nutrition solution. No pH changes or precipitates were observed. These findings indicate that 5-fluorouracil is compatible with and available from total parenteral solutions of hypertonic dextrose and amino acid in both plastic and glass containers. Use of such a system would allow for (1) a reduction in vascular access in patients receiving both treatments and (2) continued administration of nutritional support without the requirement for additional fluid volume.
Software for real-time control of a tidal liquid ventilator.
Heckman, J L; Hoffman, J; Shaffer, T H; Wolfson, M R
1999-01-01
The purpose of this project was to develop and test computer software and control algorithms designed to operate a tidal liquid ventilator. The tests were executed on a 90-MHz Pentium PC with 16 MB RAM and a prototype liquid ventilator. The software was designed using Microsoft Visual C++ (Ver. 5.0) and the Microsoft Foundation Classes. It uses a graphic user interface, is multithreaded, runs in real time, and has a built-in simulator that facilitates user education in liquid-ventilation principles. The operator can use the software to specify ventilation parameters such as the frequency of ventilation, the tidal volume, and the inspiratory-expiratory time ratio. Commands are implemented via control of the pump speed and by setting the position of two two-way solenoid-controlled valves. Data for use in monitoring and control are gathered by analog-to-digital conversion. Control strategies are implemented to maintain lung volumes and airway pressures within desired ranges, according to limits set by the operator. Also, the software allows the operator to define the shape of the flow pulse during inspiration and expiration, and to optimize perfluorochemical liquid transfer while minimizing airway pressures and maintaining the desired tidal volume. The operator can stop flow during inspiration and expiration to measure alveolar pressures. At the end of expiration, the software stores all user commands and 30 ventilation parameters into an Excel spreadsheet for later review and analysis. Use of these software and control algorithms affords user-friendly operation of a tidal liquid ventilator while providing precise control of ventilation parameters.
Berthod, Alain; Hassoun, Mahmoud
2006-05-26
The retention volumes of solutes in countercurrent chromatography (CCC) are directly proportional to their distribution coefficients, K(D) in the biphasic liquid system used as mobile and stationary phase in the CCC column. The cocurrent CCC method consists in putting the liquid "stationary" phase in slow motion in the same direction as the mobile phase. A mixture of five steroid compounds of widely differing polarities was used as a test mixture to evaluate the capabilities of the method with the biphasic liquid system made of water/methanol/ethyl acetate/heptane 6/5/6/5 (v/v) and a 53 mL CCC column of the coil planet centrifuge type. It is shown that the chromatographic resolution obtained in cocurrent CCC is very good because the solute band broadening is minimized as long as the solute is located inside the "stationary" phase. Pushing the method at its limits, it is demonstrated that the five steroids can still be (partly) separated when the flow rate of the two liquid phases is the same (2 mL/min). This is due to the higher volume of upper phase (72% of the column volume) contained inside the CCC column producing a lower linear speed compared to the aqueous lower phase linear speed. The capabilities of the cocurrent CCC method compare well with those of the gradient elution method in HPLC. Continuous detection is a problem due to the fact that two immiscible liquid phases elute from the column. It was partly solved using an evaporative light scattering detector.
Electrolyte-carbohydrate beverage prevents water loss in the early stage of high altitude training.
Yanagisawa, Kae; Ito, Osamu; Nagai, Satsuki; Onishi, Shohei
2012-01-01
To prevent water loss in the early stage of high altitude training, we focused on the effect of electrolyte-carbohydrate beverage (EC). Subjects were 16 male university students who belonged to a ski club. They had ski training at an altitude of 1,800 m. The water (WT) group drank only water, and the EC group drank only an electrolyte-carbohydrate beverage. They arrived at the training site in the late afternoon. The study started at 7 pm on the day of arrival and continued until noon of the 4(th) day. In the first 12 hours, 1 L of beverages were given. On the second and third days, 2.5 L of beverages were given. All subjects ate the same meals. Each morning while in fasting condition, subjects were weighed and blood was withdrawn for various parameters (hemoglobin, hematocrit, sodium, potassium and aldosterone). Urine was collected at 12 hour intervals for a total 60 hours (5 times). The urine volume, gravity, sodium and potassium concentrations were measured. Peripheral oxygen saturation and heart rate were measured during sleep with a pulse oximeter. Liquid intakes in both groups were similar, hence the electrolytes intake was higher in the EC group than in the WT group. The total urine volume was lower in the EC group than in the WT group, respectively (p<0.05). Plasma volume decreased in the WT group and increased in the EC group but a significant difference was not observed in the final value. Aldosterone concentration tended to be less in the EC group than in the WT group. Electrolyte-carbohydrate beverage in the early stage of high altitude training may be effective in decreasing urinary output and preventing loss of blood plasma volume.
Apparatus for the plasma destruction of hazardous gases
Kang, M.
1995-02-07
A plasma cell for destroying hazardous gases is described. An electric-discharge cell having an electrically conducting electrode onto which an alternating high-voltage waveform is impressed and a dielectric barrier adjacent thereto, together forming a high-voltage electrode, generates self-terminating discharges throughout a volume formed between this electrode and a grounded conducting liquid electrode. The gas to be transformed is passed through this volume. The liquid may be flowed, generating thereby a renewable surface. Moreover, since hydrochloric and hydrofluoric acids may be formed from destruction of various chlorofluorocarbons in the presence of water, a conducting liquid may be selected which will neutralize these corrosive compounds. The gases exiting the discharge region may be further scrubbed if additional purification is required. 4 figs.
Apparatus for the plasma destruction of hazardous gases
Kang, Michael
1995-01-01
A plasma cell for destroying hazardous gases. An electric-discharge cell having an electrically conducting electrode onto which an alternating high-voltage waveform is impressed and a dielectric barrier adjacent thereto, together forming a high-voltage electrode, generates self-terminating discharges throughout a volume formed between this electrode and a grounded conducting liquid electrode. The gas to be transformed is passed through this volume. The liquid may be flowed, generating thereby a renewable surface. Moreover, since hydrochloric and hydrofluoric acids may be formed from destruction of various chlorofluorocarbons in the presence of water, a conducting liquid may be selected which will neutralize these corrosive compounds. The gases exiting the discharge region may be further scrubbed if additional purification is required.
Catalyst for hydrotreating carbonaceous liquids
Berg, Lloyd; McCandless, Frank P.; Ramer, Ronald J.
1982-01-01
A catalyst for denitrogenating and desulfurating carbonaceous liquid such as solvent refined coal includes catalytic metal oxides impregnated within a porous base of mostly alumina with relatively large pore diameters, surface area and pore volume. The base material includes pore volumes of 0.7-0.85 ml/g, surface areas of 200-350 m.sup.2 /g and pore diameters of 85-200 Angstroms. The catalytic metals impregnated into these base materials include the oxides of Group VI metals, molybdenum and tungsten, and the oxides of Group VIII metals, nickel and cobalt, in various combinations. These catalysts and bases in combination have effectively promoted the removal of chemically combined sulfur and nitrogen within a continuous flowing mixture of carbonaceous liquid and hydrogen gas.
Liquid Photonic Crystals for Mesopore Detection.
Zhu, Biting; Fu, Qianqian; Chen, Ke; Ge, Jianping
2018-01-02
Nitrogen adsorption-desorption for mesopore characterization requires the using of expensive instrumentation, time-consuming processes, and the consumption of liquid nitrogen. Herein, a new method is developed to measure the pore parameters through mixing a mesoporous substance with a supersaturated SiO 2 colloidal solution at different temperatures, and subsequent rapid measurement of reflection changes of the precipitated liquid photonic crystals. The pore volumes and diameters of mesoporous silica were measured according to the positive correlation between unit mass reflection change (Δλ/m) and pore volume (V), and the negative correlation between average absorption temperature (T) and pore diameter (D). This new approach may provide an alternative method for fast, convenient and economical characterization of mesoporous materials. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
2013-01-01
Background Drop drying is a key factor in a wide range of technical applications, including spotted microarrays. The applied nL liquid volume provides specific reaction conditions for the immobilization of probe molecules to a chemically modified surface. Results We investigated the influence of nL and μL liquid drop volumes on the process of probe immobilization and compare the results obtained to the situation in liquid solution. In our data, we observe a strong relationship between drop drying effects on immobilization and surface chemistry. In this work, we present results on the immobilization of dye labeled 20mer oligonucleotides with and without an activating 5′-aminoheptyl linker onto a 2D epoxysilane and a 3D NHS activated hydrogel surface. Conclusions Our experiments identified two basic processes determining immobilization. First, the rate of drop drying that depends on the drop volume and the ambient relative humidity. Oligonucleotides in a dried spot react unspecifically with the surface and long reaction times are needed. 3D hydrogel surfaces allow for immobilization in a liquid environment under diffusive conditions. Here, oligonucleotide immobilization is much faster and a specific reaction with the reactive linker group is observed. Second, the effect of increasing probe concentration as a result of drop drying. On a 3D hydrogel, the increasing concentration of probe molecules in nL spotting volumes accelerates immobilization dramatically. In case of μL volumes, immobilization depends on whether the drop is allowed to dry completely. At non-drying conditions, very limited immobilization is observed due to the low oligonucleotide concentration used in microarray spotting solutions. The results of our study provide a general guideline for microarray assay development. They allow for the initial definition and further optimization of reaction conditions for the immobilization of oligonucleotides and other probe molecule classes to different surfaces in dependence of the applied spotting and reaction volume. PMID:23758982
Anagnostakis, Ioannis; Papassavas, Andreas C; Michalopoulos, Efstathios; Chatzistamatiou, Theofanis; Andriopoulou, Sofia; Tsakris, Athanassios; Stavropoulos-Giokas, Catherine
2014-01-01
Cord blood (CB) units are stored from weeks to years in liquid- or vapor-phase nitrogen until they are used for transplantation. We examined the effects of cryostorage in a mechanical freezer at -150°C on critical quality control variables of CB collections to investigate the possible use of mechanical freezers at -150°C as an alternative to storage in liquid- (or vapor-) phase nitrogen. A total of 105 CB units were thawed and washed at different time intervals (6, 12, 24, and 36 months). For every thawed CB unit, samples were removed and cell enumeration (total nucleated cells [TNCs], mononuclear cells [MNCs], CD34+, CD133+) was performed. In addition, viability was obtained with the use of flow cytometry, and recoveries were calculated. Also, total absolute colony-forming unit counts were performed and progenitor cell recoveries were studied by clonogenic assays. Significant differences (p < 0.05) were observed in certain variables (TNCs, MNC numbers, viability) when they were examined in relation with time intervals, while others (CD34+, CD133+) were relatively insensitive (p = NS) to the duration of time interval the CB units were kept in cryostorage condition. The data presented suggest that cryopreservation of CB units in a mechanical freezer at -150°C may represent an alternative cryostorage condition for CB cryopreservation. © 2013 American Association of Blood Banks.
Sun, Xiaosong; Sakai, Mikio
2016-12-01
In this study, a numerical method is developed to perform the direct numerical simulation (DNS) of gas-solid-liquid flows involving capillary effects. The volume-of-fluid method employed to track the free surface and the immersed boundary method is adopted for the fluid-particle coupling in three-phase flows. This numerical method is able to fully resolve the hydrodynamic force and capillary force as well as the particle motions arising from complicated gas-solid-liquid interactions. We present its application to liquid bridges among spherical particles in this paper. By using the DNS method, we obtain the static bridge force as a function of the liquid volume, contact angle, and separation distance. The results from the DNS are compared with theoretical equations and other solutions to examine its validity and suitability for modeling capillary bridges. Particularly, the nontrivial liquid bridges formed in triangular and tetrahedral particle clusters are calculated and some preliminary results are reported. We also perform dynamic simulations of liquid bridge ruptures subject to axial stretching and particle motions driven by liquid bridge action, for which accurate predictions are obtained with respect to the critical rupture distance and the equilibrium particle position, respectively. As shown through the simulations, the strength of the present method is the ability to predict the liquid bridge problem under general conditions, from which models of liquid bridge actions may be constructed without limitations. Therefore, it is believed that this DNS method can be a useful tool to improve the understanding and modeling of liquid bridges formed in complex gas-solid-liquid flows.
NASA Technical Reports Server (NTRS)
Lawson, D. D.
1979-01-01
A group additivity method is generated which allows estimation, from the structural formulas alone, of the energy of vaporization and the molar volume at 25 C of many nonpolar organic liquids. Using these two parameters and appropriate thermodynamic relations, the vapor pressure of the liquid phase and the solubility of various gases in nonpolar organic liquids are predicted. It is also possible to use the data to evaluate organic and some inorganic liquids for use in gas separation stages or liquids as heat exchange fluids in prospective thermochemical cycles for hydrogen production.
Agrawal, Sony; Cifelli, Steven; Johnstone, Richard; Pechter, David; Barbey, Deborah A; Lin, Karen; Allison, Tim; Agrawal, Shree; Rivera-Gines, Aida; Milligan, James A; Schneeweis, Jonathan; Houle, Kevin; Struck, Alice J; Visconti, Richard; Sills, Matthew; Wildey, Mary Jo
2016-02-01
Quantitative reverse transcription PCR (qRT-PCR) is a valuable tool for characterizing the effects of inhibitors on viral replication. The amplification of target viral genes through the use of specifically designed fluorescent probes and primers provides a reliable method for quantifying RNA. Due to reagent costs, use of these assays for compound evaluation is limited. Until recently, the inability to accurately dispense low volumes of qRT-PCR assay reagents precluded the routine use of this PCR assay for compound evaluation in drug discovery. Acoustic dispensing has become an integral part of drug discovery during the past decade; however, acoustic transfer of microliter volumes of aqueous reagents was time consuming. The Labcyte Echo 525 liquid handler was designed to enable rapid aqueous transfers. We compared the accuracy and precision of a qPCR assay using the Labcyte Echo 525 to those of the BioMek FX, a traditional liquid handler, with the goal of reducing the volume and cost of the assay. The data show that the Echo 525 provides higher accuracy and precision compared to the current process using a traditional liquid handler. Comparable data for assay volumes from 500 nL to 12 µL allowed the miniaturization of the assay, resulting in significant cost savings of drug discovery and process streamlining. © 2015 Society for Laboratory Automation and Screening.
Šesták, Jozef; Kahle, Vladislav
2014-07-11
Performing gradient liquid chromatography at constant pressure instead of constant flow rate has serious potential for shortening the analysis time and increasing the productivity of HPLC instruments that use gradient methods. However, in the constant pressure mode the decreasing column permeability during a long period of time negatively affects the repeatability of retention time. Thus a volume-based approach, in which the detector signal is plotted as a function of retention volume, must be taken into consideration. Traditional HPLC equipment, however, requires quite complex hardware and software modifications in order to work at constant pressure and in the volume-based mode. In this short communication, a low cost and easily feasible pressure-controlled extension of the previously described simple gradient liquid chromatography platform is proposed. A test mixture of four nitro esters was separated by 10-60% (v/v) acetone/water gradient and a high repeatability of retention volumes at 20MPa (RSD less than 0.45%) was realized. Separations were also performed at different values of pressure (20, 25, and 31MPa), and only small variations of the retention volumes (up to 0.8%) were observed. In this particular case, the gain in the analysis speed of 7% compared to the constant flow mode was realized at a constant pressure. Copyright © 2014 Elsevier B.V. All rights reserved.
Nilsson, C L; Puchades, M; Westman, A; Blennow, K; Davidsson, P
1999-01-01
Pleural effusion may occur in patients suffering from physical trauma or systemic disorders such as infection, inflammation, or cancer. In order to investigate proteins in a pleural exudate from a patient with severe pneumonia, we used a strategy that combined preparative two-dimensional liquid-phase electrophoresis (2-D LPE), matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) and Western blotting. Preparative 2-D LPE is based on the same principles as analytical 2-D gel electrophoresis, except that the proteins remain in liquid phase during the entire procedure. In the first dimension, liquid-phase isoelectric focusing allows for the enrichment of proteins in liquid fractions. In the Rotofor cell, large volumes (up to 55 mL) and protein amounts (up to 1-2 g) can be loaded. Several low abundance proteins, cystatin C, haptoglobin, transthyretin, beta2-microglobulin, and transferrin, were detected after liquid-phase isoelectric focusing, through Western blotting analysis, in a pleural exudate (by definition, >25 g/L total protein). Direct MALDI-TOF-MS analysis of proteins in a Rotofor fraction is demonstrated as well. MALDI-TOF-MS analysis of a tryptic digest of a continuous elution sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) fraction confirmed the presence of cystatin C. By applying 2-D LPE, MALDI-TOF-MS, and Western blotting to the analysis of this pleural exudate, we were able to confirm the identity of proteins of potential diagnostic value. Our findings serve to illustrate the usefulness of this combination of methods in the analysis of pathological fluids.
Evaporation of Nanosuspensions on Substrates with Different Hydrophobicity.
Perrin, Lionel; Pajor-Swierzy, Anna; Magdassi, Shlomo; Kamyshny, Alexander; Ortega, Francisco; Rubio, Ramón G
2018-01-24
Liquid drop evaporation on surfaces is present in many industrial and medical applications, e.g., printed electronics, spraying of pesticides, DNA mapping, etc. Despite this strong interest, a theoretical description of the dynamic of the evaporation of complex liquid mixtures and nanosuspensions is still lacking. Indeed, one of the aspects that have not been included in the current theoretical descriptions is the competition between the kinetics of evaporation and the adsorption of surfactants and/or particles at the liquid/vapor and liquid/solid interfaces. Materials formed by an electrically isolating solid on which a patterned conducting layer was formed by the deposits left after drop evaporation have been considered as very promising for building electrical circuits on flexible plastic substrates. In this work, we have done an exhaustive study of the evaporation of nanosuspensions of latex and hydrophobized silver nanoparticles on four substrates of different hydrophobicity. The advancing and receding contact angles as well as the time dependence of the volume of the droplets have been measured over a broad range of particle concentrations. Also, mixtures of silver particles and a surfactant, commonly used in industrial printing, have been examined. Furthermore, the adsorption kinetics at both the air/liquid and solid/liquid interfaces have been measured. Whereas the latex particles do not adsorb at the solid/liquid and only slightly reduce the surface tension, the silver particles strongly adsorb at both interfaces. The experimental results of the evaporation process were compared with the predictions of the theory of Semenov et al. (Evaporation of Sessile Water Droplets: Universal Behavior in the Presence of Contact Angle Hysteresis. Colloids Surf. Physicochem. Eng. Asp. 2011, 391 (1-3), 135-144) and showed surprisingly good agreement despite that the theory was developed for pure liquids. The morphology of the deposits left by the droplets after total evaporation was studied by scanning electronic microscopy, and the effects of the substrate, the particle nature, and their concentrations on these patterns are discussed.
Volume of a laser-induced microjet
NASA Astrophysics Data System (ADS)
Kawamoto, Sennosuke; Hayasaka, Keisuke; Noguchi, Yuto; Tagawa, Yoshiyuki
2015-11-01
Needle-free injection systems are of great importance for medical treatments. In spite of their great potential, these systems are not commonly used. One of the common problems is strong pain caused by diffusion shape of the jet. To solve this problem, the usage of a high-speed highly-focused microjet as needle-free injection system is expected. It is thus crucial to control important indicators such as ejected volume of the jet for its safe application. We conduct experiments to reveal which parameter influences mostly the ejected volume. In the experiments, we use a glass tube of an inner diameter of 500 micro-meter, which is filled with the liquid. One end is connected to a syringe and the other end is opened. Radiating the pulse laser instantaneously vapors the liquid, followed by the generation of a shockwave. We find that the maximum volume of a laser-induced bubble is approximately proportional to the ejected volume. It is also found that the occurrence of cavitation does not affect the ejected volume while it changes the jet velocity.
NASA Astrophysics Data System (ADS)
Kim, Dokyun; Bravo, Luis; Matusik, Katarzyna; Duke, Daniel; Kastengren, Alan; Swantek, Andy; Powell, Christopher; Ham, Frank
2016-11-01
One of the major concerns in modern direct injection engines is the sensitivity of engine performance to fuel characteristics. Recent works have shown that even slight differences in fuel properties can cause significant changes in efficiency and emission of an engine. Since the combustion process is very sensitive to the fuel/air mixture formation resulting from disintegration of liquid jet, the precise assessment of fuel sensitivity on liquid jet atomization process is required first to study the impact of different fuels on the combustion. In the present study, the breaking process of a liquid jet from a diesel injector injecting into a quiescent gas chamber is investigated numerically and experimentally for different liquid fuels (n-dodecane, iso-octane, CAT A2 and C3). The unsplit geometric Volume-of-Fluid method is employed to capture the phase interface in Large-eddy simulations and results are compared against the radiography measurement from Argonne National Lab including jet penetration, liquid mass distribution and volume fraction. The breakup characteristics will be shown for different fuels as well as droplet PDF statistics to demonstrate the influences of the physical properties on the primary atomization of liquid jet. Supported by HPCMP FRONTIER award, US DOD, Office of the Army.
Chlou, G.T.; Kile, D.E.; Malcolm, R.L.
1988-01-01
Vapor sorption of water, ethanol, benzene, hexane, carbon tetrachloride, 1,1,1-trichloroethane, trichloroethylene, tetrachloroethylene, and 1,2-dibromoethane on (Sanhedron) soil humic acid has been determined at room temperature. Isotherms for all organic liquids are highly linear over a wide range of relative pressure (P/P??), characteristic of the partitioning (dissolution) of the organic compounds in soil humic acid. Polar liquids exhibit markedly greater sorption capacities on soil humic acid than relatively nonpolar liquids, in keeping with the polar nature of the soil humic acid as a partition medium. The limiting sorption (partition) capacities of relatively non-polar liquids are remarkably similar when expressed in terms of volumes per unit weight of soil humic acid. The soil humic acid is found to be about half as effective as soil organic matter in sorption of relatively nonpolar organic compounds. The nearly constant limiting sorption capacity for nonpolar organic liquids with soil humic acid on a volume-to-weight basis and its efficiency in sorption relative to soil organic matter provide a basis for predicting the approximate sorption (partition) coefficients of similar compounds in uptake by soil in aqueous systems.
Investigation of energy dissipation due to contact angle hysteresis in capillary effect
NASA Astrophysics Data System (ADS)
Athukorallage, Bhagya; Iyer, Ram
2016-06-01
Capillary action or Capillarity is the ability of a liquid to flow in narrow spaces without the assistance of, and in opposition to, external forces like gravity. Three effects contribute to capillary action, namely, adhesion of the liquid to the walls of the confining solid; meniscus formation; and low Reynolds number fluid flow. We investigate the dissipation of energy during one cycle of capillary action, when the liquid volume inside a capillary tube first increases and subsequently decreases while assuming quasi-static motion. The quasi-static assumption allows us to focus on the wetting phenomenon of the solid wall by the liquid and the formation of the meniscus. It is well known that the motion of a liquid on an non-ideal surface involves the expenditure of energy due to contact angle hysteresis. In this paper, we derive the equations for the menisci and the flow rules for the change of the contact angles for a liquid column in a capillary tube at a constant temperature and volume by minimizing the Helmholtz free energy using calculus of variations. We describe the numerical solution of these equations and present results from computations for the case of a capillary tube with 1 mm diameter.
Bessemans, Laurent; Jully, Vanessa; de Raikem, Caroline; Albanese, Mathieu; Moniotte, Nicolas; Silversmet, Pascal; Lemoine, Dominique
2016-01-01
High-throughput screening technologies are increasingly integrated into the formulation development process of biopharmaceuticals. The performance of liquid handling systems is dependent on the ability to deliver accurate and precise volumes of specific reagents to ensure process quality. We have developed an automated gravimetric calibration procedure to adjust the accuracy and evaluate the precision of the TECAN Freedom EVO liquid handling system. Volumes from 3 to 900 µL using calibrated syringes and fixed tips were evaluated with various solutions, including aluminum hydroxide and phosphate adjuvants, β-casein, sucrose, sodium chloride, and phosphate-buffered saline. The methodology to set up liquid class pipetting parameters for each solution was to split the process in three steps: (1) screening of predefined liquid class, including different pipetting parameters; (2) adjustment of accuracy parameters based on a calibration curve; and (3) confirmation of the adjustment. The run of appropriate pipetting scripts, data acquisition, and reports until the creation of a new liquid class in EVOware was fully automated. The calibration and confirmation of the robotic system was simple, efficient, and precise and could accelerate data acquisition for a wide range of biopharmaceutical applications. PMID:26905719
Behbahani, Mohammad; Najafi, Fatemeh; Bagheri, Saman; Bojdi, Majid Kalate; Hassanlou, Parmoon Ghareh; Bagheri, Akbar
2014-04-01
A simple, rapid, and efficient sample pretreatment technique, based on solvent-based de-emulsification dispersive liquid-liquid microextraction (SD-DLLME), followed by high performance liquid chromatography (HPLC) has been developed for simultaneous preconcentration and trace detection of 2,4-dichlorophenoxyacetic acid (2,4-D) and 2-methyl-4-chlorophenoxyacetic acid (MCPA) in water and urine samples. Some parameters such as acidity of solution, the amount of salt, type, and volume of extraction solvents, type of disperser/de-emulsifier solvent, and its volume were investigated and optimized. Under optimum extraction conditions, the limits of detections (LODs) of this method for MCPA and 2,4-D were 0.2 and 0.6 μg L(-1) (based on 3S(b)/m) in water and 0.4 and 1.6 μg L(-1) in urine, respectively. Furthermore, dynamic linear range of this method for MCPA and 2,4-D was 1-300 and 2-400 μg L(-1), repectively. Finally, the applicability of the proposed method was evaluated by extraction and determination of the herbicides in urine and different water samples.
A combined Eulerian-volume of fraction-Lagrangian method for atomization simulation
NASA Technical Reports Server (NTRS)
Seung, S. P.; Chen, C. P.; Ziebarth, John P.
1994-01-01
The tracking of free surfaces between liquid and gas phases and analysis of the interfacial phenomena between the two during the atomization and breakup process of a liquid fuel jet is modeled. Numerical modeling of liquid-jet atomization requires the resolution of different conservation equations. Detailed formulation and validation are presented for the confined dam broken problem, the water surface problem, the single droplet problem, a jet breakup problem, and the liquid column instability problem.
Structure and phase behavior of a confined nanodroplet composed of the flexible chain molecules.
Kim, Soon-Chul; Kim, Eun-Young; Seong, Baek-Seok
2011-04-28
A polymer density functional theory has been employed for investigating the structure and phase behaviors of the chain polymer, which is modelled as the tangentially connected sphere chain with an attractive interaction, inside the nanosized pores. The excess free energy of the chain polymer has been approximated as the modified fundamental measure-theory for the hard spheres, the Wertheim's first-order perturbation for the chain connectivity, and the mean-field approximation for the van der Waals contribution. For the value of the chemical potential corresponding to a stable liquid phase in the bulk system and a metastable vapor phase, the flexible chain molecules undergo the liquid-vapor transition as the pore size is reduced; the vapor is the stable phase at small volume, whereas the liquid is the stable phase at large volume. The wide liquid-vapor coexistence curve, which explains the wide range of metastable liquid-vapor states, is observed at low temperature. The increase of temperature and decrease of pore size result in a narrowing of liquid-vapor coexistence curves. The increase of chain length leads to a shift of the liquid-vapor coexistence curve towards lower values of chemical potential. The coexistence curves for the confined phase diagram are contained within the corresponding bulk liquid-vapor coexistence curve. The equilibrium capillary phase transition occurs at a higher chemical potential than in the bulk phase.
Uysal, Deniz; Karadaş, Cennet; Kara, Derya
2017-05-01
A new, simple, efficient, and environmentally friendly ionic liquid dispersive liquid-liquid microextraction method was developed for the determination of irinotecan, an anticancer drug, in water and urine samples using UV-Vis spectrophotometry. The ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate was used as the extraction solvent, and ethanol was used as the disperser solvent. The main parameters affecting the extraction efficiency, including sample pH, volume of the ionic liquid, choice of the dispersive solvent and its volume, concentration of NaCl, and extraction and centrifugation times, were investigated and optimized. The effect of interfering species on the recovery of irinotecan was also examined. Under optimal conditions, the LOD (3σ) was 48.7 μg/L without any preconcentration. Because the urine sample was diluted 10-fold, the LOD for urine would be 487 μg/L. However, this could be improved 16-fold if preconcentration using a 40 mL aliquot of the sample is used. The proposed method was successfully applied to the determination of irinotecan in tap water, river water, and urine samples spiked with 10.20 mg/L for the water samples and 8.32 mg/L for the urine sample. The average recovery values of irinotecan determined were 99.1% for tap water, 109.4% for river water, and 96.1% for urine.
Viñas, Pilar; Pastor-Belda, Marta; Campillo, Natalia; Bravo-Bravo, María; Hernández-Córdoba, Manuel
2014-06-01
Capillary liquid chromatography (LC) is used for the determination of tocopherols and tocotrienols in cosmetic products. Dispersive liquid-liquid microextraction (DLLME) allows the analytes to be preconcentrated into a very small volume of organic solvent which is then injected into the chromatograph running at a very low flow rate. Pressurized liquid extraction (PLE) at a high temperature and pressure was used to isolate vitamin E forms from cosmetics. The Taguchi experimental method was used to optimize the factors affecting DLLME. The parameters selected were 2mL of acetonitrile (disperser solvent), 100μL carbon tetrachloride (extraction solvent) and 10mL aqueous solution. A volume of 5μL of the organic phase was injected into the reversed-phase capillary LC system equipped with a diode array detector and using an isocratic mobile phase composed of an 95:5 (v/v) methanol:water mixture at a flow-rate of 20μLmin(-1). Quantification was carried out using aqueous standards and detection limits were in the range 0.1-0.5ngmL(-1), corresponding to 3-15ngg(-1) in the cosmetic sample. The recoveries were in the 87-105% range, with RSDs lower than 7.8%. The method was validated according to international guidelines and using a certified reference material. Copyright © 2014 Elsevier B.V. All rights reserved.
30 CFR 250.1201 - Definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Resources BUREAU OF OCEAN ENERGY MANAGEMENT, REGULATION, AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR... measurement. The measured volumes are used in the allocation process. Liquid hydrocarbons (free liquids... at which custody transfer takes place (not necessarily a royalty meter). Seal—a device or approved...
Process for immobilizing radioactive boric acid liquid wastes
Greenhalgh, Wilbur O.
1986-01-01
A method of immobilizing boric acid liquid wastes containing radionuclides by neutralizing the solution and evaporating the resulting precipitate to near dryness. The dry residue is then fused into a reduced volume, insoluble, inert, solid form containing substantially all the radionuclides.
Liquid Rocket Booster (LRB) for the Space Transportation System (STS) systems study, volume 2
NASA Technical Reports Server (NTRS)
1989-01-01
The Liquid Rocket Booster (LRB) Systems Definition Handbook presents the analyses and design data developed during the study. The Systems Definition Handbook (SDH) contains three major parts: the LRB vehicles definition; the Pressure-Fed Booster Test Bed (PFBTB) study results; and the ALS/LRB study results. Included in this volume are the results of all trade studies; final configurations with supporting rationale and analyses; technology assessments; long lead requirements for facilities, materials, components, and subsystems; operational requirements and scenarios; and safety, reliability, and environmental analyses.
Attoliter Control of Microliquid
NASA Astrophysics Data System (ADS)
Imura, Fumito; Kuroiwa, Hiroyuki; Nakada, Akira; Kosaka, Kouji; Kubota, Hiroshi
2007-11-01
The technology of the sub-femtoliter volume control of liquids in nanometer range pipettes (nanopipettes) has been developed for carrying out surgical operations on living cells. We focus attention on an interface forming between oil and water in a nanopipette. The interface position can be moved by increasing or decreasing the input pressure. If the volume of liquid in the nanopipette can be controlled by moving the position of the interface, cell organelles can be discharged or suctioned and a drug-solution can be injected into the cell. Quantity volume control in the pico-attoliter range using a tapered nanopipette is controlled by the condition of an interface with a convex shape toward the top of the nanopipette. The volume can be controlled by the input pressure corresponding to the interfacial radius without the use of a microscope by preliminarily preparing the pipette shape and the interface radius as a function of the input pressure.
NASA Astrophysics Data System (ADS)
Achsah, R. S.; Shyam, S.; Mayuri, N.; Anantharaj, R.
2018-04-01
Deep eutectic solvents (DES) and ionic liquids (ILs) have their applications in various fields of research and in industries due to their attractive physiochemical properties. In this study, the combined thermodynamic properties of DES (choline chloride-glycerol) + IL1 (1-butyl-3-methylimiazolium acetate) and DES(choline chloride-glycerol) + IL2 (1-ethyl-3-methylimadzolium ethyl sulphate) have been studied. The thermodynamic properties such as excess molar volume, partial molar volume, excess partial molar volume and apparent molar volume were calculated for different mole fractions ranging from 0 to 1 and varying temperatures from 293.15 K to 343.15 K. In order to know the solvent properties of DESs and ILs mixtures at different temperatures and their molecular interactions to enhance the solvent performance and process efficiency at fixed composition and temperature the thermodynamic properties were analyzed.
Aseptic minimum volume vitrification technique for porcine parthenogenetically activated blastocyst.
Lin, Lin; Yu, Yutao; Zhang, Xiuqing; Yang, Huanming; Bolund, Lars; Callesen, Henrik; Vajta, Gábor
2011-01-01
Minimum volume vitrification may provide extremely high cooling and warming rates if the sample and the surrounding medium contacts directly with the respective liquid nitrogen and warming medium. However, this direct contact may result in microbial contamination. In this work, an earlier aseptic technique was applied for minimum volume vitrification. After equilibration, samples were loaded on a plastic film, immersed rapidly into factory derived, filter-sterilized liquid nitrogen, and sealed into sterile, pre-cooled straws. At warming, the straw was cut, the filmstrip was immersed into a 39 degree C warming medium, and the sample was stepwise rehydrated. Cryosurvival rates of porcine blastocysts produced by parthenogenetical activation did not differ from control, vitrified blastocysts with Cryotop. This approach can be used for minimum volume vitrification methods and may be suitable to overcome the biological dangers and legal restrictions that hamper the application of open vitrification techniques.
Molar volume and adsorption isotherm dependence of capillary forces in nanoasperity contacts.
Asay, David B; Kim, Seong H
2007-11-20
The magnitude of the capillary force at any given temperature and adsorbate partial pressure depends primarily on four factors: the surface tension of the adsorbate, its liquid molar volume, its isothermal behavior, and the contact geometry. At large contacting radii, the adsorbate surface tension and the contact geometry are dominating. This is the case of surface force apparatus measurements and atomic force microscopy (AFM) experiments with micrometer-size spheres. However, as the size of contacting asperities decreases to the nanoscale as in AFM experiments with sharp tips, the molar volume and isotherm of the adsorbate become very important to capillary formation as well as capillary adhesion. This effect is experimentally and theoretically explored with simple alcohol molecules (ethanol, 1-butanol, and 1-pentanol) which have comparable surface tensions but differing liquid molar volumes. Adsorption isotherms for these alcohols on silicon oxide are also reported.
Thermo-mechanical concepts applied to modeling liquid propellant rocket engine stability
NASA Astrophysics Data System (ADS)
Kassoy, David R.; Norris, Adam
2016-11-01
The response of a gas to transient, spatially distributed energy addition can be quantified mathematically using thermo-mechanical concepts available in the literature. The modeling demonstrates that the ratio of the energy addition time scale to the acoustic time scale of the affected volume, and the quantity of energy added to that volume during the former determine the whether the responses to heating can be described as occurring at nearly constant volume, fully compressible or nearly constant pressure. Each of these categories is characterized by significantly different mechanical responses. Application to idealized configurations of liquid propellant rocket engines provides an opportunity to identify physical conditions compatible with gasdynamic disturbances that are sources of engine instability. Air Force Office of Scientific Research.
JANNAF 35th Combustion Subcommittee Meeting. Volume 1
NASA Technical Reports Server (NTRS)
Fry, Ronald S. (Editor); Gannaway, Mary T. (Editor); Rognan, Melanie (Editor)
1998-01-01
Volume 1, the first of two volumes is a compilation of 63 unclassified/unlimited distribution technical papers presented at the 35th meeting of the Joint Army-Navy-NASA-Air Force (JANNAF) Combustion Subcommittee (CS) held jointly with the 17th Propulsion Systems Hazards Subcommittee (PSHS) and Airbreathing Propulsion Subcommittee (APS). The meeting was held on 7-11 December 1998 at Raytheon Systems Company and the Marriott Hotel, Tucson, AZ. Topics covered include solid gun propellant processing, ignition and combustion, charge concepts, barrel erosion and flash, gun interior ballistics, kinetics and molecular modeling, ETC gun modeling, simulation and diagnostics, and liquid gun propellant combustion; solid rocket motor propellant combustion, combustion instability fundamentals, motor instability, and measurement techniques; and liquid and hybrid rocket combustion.
Thermo-acoustical molecular interaction study in binary mixtures of glycerol and ethylene glycol
NASA Astrophysics Data System (ADS)
Kaur, Kirandeep; Juglan, K. C.; Kumar, Harsh
2017-07-01
Ultrasonic velocity, density and viscosity are measured over the entire composition range for binary liquid mixtures of glycerol (CH2OH-CHOH-CH2OH) and ethylene glycol (HOCH2CH2OH) at different temperatures and constant frequency of 2MHz using ultrasonic interferometer, specific gravity bottle and viscometer respectively. Measured experimental values are used to obtained various acoustical parameters such as adiabatic compressibility, acoustic impedance, intermolecular free length, relaxation time, ultrasonic attenuation, effective molar weight, free volume, available volume, molar volume, Wada's constant, Rao's constant, Vander Waal's constant, internal pressure, Gibb's free energy and enthalpy. The variation in acoustical parameters are interpreted in terms of molecular interactions between the components of molecules of binary liquid mixtures.
In situ TEM and analytical STEM studies of ZnO nanotubes with Sn cores and Sn nanodrops
NASA Astrophysics Data System (ADS)
Ortega, Y.; Jäger, W.; Piqueras, J.; Häussler, D.; Fernández, P.
2013-10-01
ZnO nanorods with Sn core regions grown by a thermal evaporation-deposition method from a mixture of SnO2 and ZnS powders as precursors, are used to study the behaviour of liquid metal in the nanotubes' core regions and the formation of liquid metal nanodrops at the tube ends by in situ TEM experiments. The compositions of the core materials and of the nanodrops were assessed by employing HAADF-STEM imaging and spatially resolved EDXS measurements. By applying variable thermal load through changing the electron-beam flux of the electron microscope, melting of the metallic core can be induced and the behaviour of the liquid metal of the nanorods can be monitored locally. Within the nanorod core, melting and reversible thermal expansion and contraction of Sn core material is reproducibly observed. For nanotubes with core material near-tip regions, a nanodrop emerges from the tip upon melting the core material, followed by reabsorption of the melt into the core and re-solidification upon decreasing the heat load, being reminiscent of a ‘soldering nanorod’. The radius of the liquid nanodrop can reach a few tens of nanometres, containing a total volume of 10-20 up to 10-18 l of liquid Sn. In situ TEM confirms that the radius of the nanodrop can be controlled via the thermal load: it increases with increasing temperature and decreases with decreasing temperature. In addition, some phenomena related to structure modifications during extended electron-beam exposure are also described.
NASA Astrophysics Data System (ADS)
Fan, Jiwen; Ghan, Steven; Ovchinnikov, Mikhail; Liu, Xiaohong; Rasch, Philip J.; Korolev, Alexei
2011-01-01
Two types of Arctic mixed-phase clouds observed during the ISDAC and M-PACE field campaigns are simulated using a 3-dimensional cloud-resolving model (CRM) with size-resolved cloud microphysics. The modeled cloud properties agree reasonably well with aircraft measurements and surface-based retrievals. Cloud properties such as the probability density function (PDF) of vertical velocity (w), cloud liquid and ice, regimes of cloud particle growth, including the Wegener-Bergeron-Findeisen (WBF) process, and the relationships among properties/processes in mixed-phase clouds are examined to gain insights for improving their representation in General Circulation Models (GCMs). The PDF of the simulated w is well represented by a Gaussian function, validating, at least for arctic clouds, the subgrid treatment used in GCMs. The PDFs of liquid and ice water contents can be approximated by Gamma functions, and a Gaussian function can describe the total water distribution, but a fixed variance assumption should be avoided in both cases. The CRM results support the assumption frequently used in GCMs that mixed phase clouds maintain water vapor near liquid saturation. Thus, ice continues to grow throughout the stratiform cloud but the WBF process occurs in about 50% of cloud volume where liquid and ice co-exist, predominantly in downdrafts. In updrafts, liquid and ice particles grow simultaneously. The relationship between the ice depositional growth rate and cloud ice strongly depends on the capacitance of ice particles. The simplified size-independent capacitance of ice particles used in GCMs could lead to large deviations in ice depositional growth.
Padró, Juan M; Pellegrino Vidal, Rocío B; Echevarria, Romina N; Califano, Alicia N; Reta, Mario R
2015-05-01
Chagas disease constitutes a major public health problem in Latin America. Human breast milk is a biological sample of great importance for the analysis of therapeutic drugs, as unwanted exposure through breast milk could result in pharmacological effects in the nursing infant. Thus, the goal of breast milk drug analysis is to inquire to which extent a neonate may be exposed to a drug during lactation. In this work, we developed an analytical technique to quantify benznidazole and nifurtimox (the two antichagasic drugs currently available for medical treatment) in human breast milk, with a simple sample pretreatment followed by an ionic-liquid-based dispersive liquid-liquid microextraction combined with high-performance liquid chromatography and UV detection. For this technique, the ionic liquid 1-octyl-3-methylimidazolium hexafluorophosphate has been used as the "extraction solvent." A central composite design was used to find the optimum values for the significant variables affecting the extraction process: volume of ionic liquid, volume of dispersant solvent, ionic strength, and pH. At the optimum working conditions, the average recoveries were 77.5 and 89.7%, the limits of detection were 0.06 and 0.09 μg/mL and the interday reproducibilities were 6.25 and 5.77% for benznidazole and nifurtimox, respectively. The proposed methodology can be considered sensitive, simple, robust, accurate, and green. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wider-Opening Dewar Flasks for Cryogenic Storage
NASA Technical Reports Server (NTRS)
Ruemmele, Warren P.; Manry, John; Stafford, Kristin; Bue, Grant; Krejci, John; Evernden, Bent
2010-01-01
Dewar flasks have been proposed as containers for relatively long-term (25 days) storage of perishable scientific samples or other perishable objects at a temperature of 175 C. The refrigeration would be maintained through slow boiling of liquid nitrogen (LN2). For the purposes of the application for which these containers were proposed, (1) the neck openings of commercial off-the-shelf (COTS) Dewar flasks are too small for most NASA samples; (2) the round shapes of the COTS containers give rise to unacceptably low efficiency of packing in rectangular cargo compartments; and (3) the COTS containers include metal structures that are too thermally conductive, such that they cannot, without exceeding size and weight limits, hold enough LN2 for the required long-term-storage. In comparison with COTS Dewar flasks, the proposed containers would be rectangular, yet would satisfy the long-term storage requirement without exceeding size and weight limits; would have larger neck openings; and would have greater sample volumes, leading to a packing efficiency of about double the sample volume as a fraction of total volume. The proposed containers would be made partly of aerospace- type composite materials and would include vacuum walls, multilayer insulation, and aerogel insulation.
Growth and yield of quaking aspen in North-central Minnesota.
Bryce E. Schlaegel
1971-01-01
Summaries of total and merchantable stand data from 34 permanent sample plots were used to derive equations for predicting present and future stand volumes. Equations are presented for predicting total cubic-foot volume, ratio of merchantable volume to total volume, and future stand diameter, heights, and basal area. Yield tables are given for total stand volume and...
Constraints on both the quadratic and quartic symmetry energy coefficients by 2β --decay energies
NASA Astrophysics Data System (ADS)
Wan, Niu; Xu, Chang; Ren, Zhongzhou; Liu, Jie
2018-05-01
In this Rapid Communication, the 2 β- -decay energies Q (2 β-) given in the atomic mass evaluation are used to extract not only the quadratic volume symmetry energy coefficient csymv, but also the quartic one csym,4 v. Based on the modified Bethe-Weizsäcker nuclear mass formula of the liquid-drop model, the decay energy Q (2 β-) is found to be closely related to both the quadratic and quartic symmetry energy coefficients csymv and csym,4 v. There are totally 449 data of decay energies Q (2 β-) used in the present analysis where the candidate nuclei are carefully chosen by fulfilling the following criteria: (1) large neutron-proton number difference N -Z , (2) large isospin asymmetry I , and (3) limited shell effect. The values of csymv and csym,4 v are extracted to be 29.345 and 3.634 MeV, respectively. Moreover, the quadratic surface-volume symmetry energy coefficient ratio is determined to be κ =csyms/csymv=1.356 .
NASA Astrophysics Data System (ADS)
Wood, Michael J.; Aristizabal, Felipe; Coady, Matthew; Nielson, Kent; Ragogna, Paul J.; Kietzig, Anne-Marie
2018-02-01
The production of millimetric liquid droplets has importance in a wide range of applications both in the laboratory and industrially. As such, much effort has been put forth to devise methods to generate these droplets on command in a manner which results in high diameter accuracy and precision, well-defined trajectories followed by successive droplets and low oscillations in droplet shape throughout their descents. None of the currently employed methods of millimetric droplet generation described in the literature adequately addresses all of these desired droplet characteristics. The reported methods invariably involve the cohesive separation of the desired volume of liquid from the bulk supply in the same step that separates the single droplet from the solid generator. We have devised a droplet generation device which separates the desired volume of liquid within a tee-apparatus in a step prior to the generation of the droplet which has yielded both high accuracy and precision of the diameters of the final droplets produced. Further, we have engineered a generating tip with extreme antiwetting properties which has resulted in reduced adhesion forces between the liquid droplet and the solid tip. This has yielded the ability to produce droplets of low mass without necessitating different diameter generating tips or the addition of surfactants to the liquid, well-defined droplet trajectories, and low oscillations in droplet volume. The trajectories and oscillations of the droplets produced have been assessed and presented quantitatively in a manner that has been lacking in the current literature.
Cheng, Heyong; Shen, Lihuan; Liu, Jinhua; Xu, Zigang; Wang, Yuanchao
2018-04-01
Nanoliter high-performance liquid chromatography shows low consumption of solvents and samples, offering one of the best choices for arsenic speciation in precious samples in combination with inuctively coupled plasma mass spectrometry. A systematic investigation on coupling nanoliter high-performance liquid chromatography to inductively coupled plasma mass spectrometry from instrument design to injected sample volume and mobile phase was performed in this study. Nanoflow mobile phase was delivered by flow splitting using a conventional high-pressure pump with reuse of mobile phase waste. Dead volume was minimized to 60 nL for the sheathless interface based on the previously developed nanonebulizer. Capillary columns for nanoliter high-performance liquid chromatography were found to be sensitive to sample loading volume. An apparent difference was also found between the mobile phases for nanoliter and conventional high-performance liquid chromatography. Baseline separation of arsenite, arsenate, monomethylarsenic, and dimethylarsenic was achieved within 11 min on a 15 cm C 18 capillary column and within 12 min on a 25 cm strong anion exchange column. Detection limits of 0.9-1.8 μg/L were obtained with precisions variable in the range of 1.6-4.2%. A good agreement between determined and certified values of a certified reference material of human urine (GBW 09115) validated its accuracy along with good recoveries (87-102%). © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Process for immobilizing radioactive boric acid liquid wastes
Greenhalgh, W.O.
1984-05-10
Disclosed is a method of immobilizing boric acid liquid wastes containing radionuclides by neutralizing the solution and evaporating the resulting precipitate to near dryness. The dry residue is then fused into a reduced volume, insoluble, inert, solid form containing substantially all the radionuclides.
29 CFR 1910.1030 - Bloodborne pathogens.
Code of Federal Regulations, 2010 CFR
2010-07-01
... designated representative. Engineering controls means controls (e.g., sharps disposal containers, self...-volume or high concentration production of HIV or HBV. Regulated Waste means liquid or semi-liquid blood... research-laboratory-scale amounts of HIV or HBV. Research laboratories may produce high concentrations of...
Wang, Zhibing; Hu, Jianxue; Du, Hongxia; He, Shuang; Li, Qing; Zhang, Hanqi
2016-06-05
The microwave-assisted ionic liquid homogeneous liquid-liquid microextraction (MA-IL-HLLME) coupled with high performance liquid chromatography with diode array detection (HPLC-DAD) was developed for the determination of anthraquinones, including aloe-emodin, emodin, chrysophanol and physcion in root of Rheum palmatum L. Several experimental parameters influencing the extraction efficiency, including amount of sample, type and volume of ionic liquid, volume and pH value of extraction medium, microwave power and extraction time, concentration of NH4PF6 as well as centrifugal condition were optimized. When 140μL of ionic liquid ([C8MIM][BF4]) was used as an extraction solvent, target analytes can be extracted from sample matrix in one minute with the help of microwave irradiation. The MA-IL-HLLME is simple and quick. The calibration curves exhibited good linear relationship (r>0.9984). The limits of detection and quantification were in the range of 0.015-0.026 and 0.051-0.088μgmL(-1), respectively. The spiked recovery for each analyte was in the range of 81.13-93.07% with relative standard deviations lower than 6.89%. The present method is free of volatile organic solvents, and represents lower expenditures of sample, extraction time and solvent, compared with ultrasonic and heat reflux extraction. The results indicated that the present method can be successfully applied to the determination of anthraquinones in medicinal plant. Copyright © 2016 Elsevier B.V. All rights reserved.
Design of the protoDUNE raw data management infrastructure
Fuess, S.; Illingworth, R.; Mengel, M.; ...
2017-10-01
The Deep Underground Neutrino Experiment (DUNE) will employ a set of Liquid Argon Time Projection Chambers (LArTPC) with a total mass of 40 kt as the main components of its Far Detector. In order to validate this technology and characterize the detector performance at full scale, an ambitious experimental program (called “protoDUNE”) has been initiated which includes a test of the large-scale prototypes for the single-phase and dual-phase LArTPC technologies, which will run in a beam at CERN. The total raw data volume that is slated to be collected during the scheduled 3-month beam run is estimated to be inmore » excess of 2.5 PB for each detector. This data volume will require that the protoDUNE experiment carefully design the DAQ, data handling and data quality monitoring systems to be capable of dealing with challenges inherent with peta-scale data management while simultaneously fulfilling the requirements of disseminating the data to a worldwide collaboration and DUNE associated computing sites. Here in this paper, we present our approach to solving these problems by leveraging the design, expertise and components created for the LHC and Intensity Frontier experiments into a unified architecture that is capable of meeting the needs of protoDUNE.« less
Design of the protoDUNE raw data management infrastructure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fuess, S.; Illingworth, R.; Mengel, M.
The Deep Underground Neutrino Experiment (DUNE) will employ a set of Liquid Argon Time Projection Chambers (LArTPC) with a total mass of 40 kt as the main components of its Far Detector. In order to validate this technology and characterize the detector performance at full scale, an ambitious experimental program (called “protoDUNE”) has been initiated which includes a test of the large-scale prototypes for the single-phase and dual-phase LArTPC technologies, which will run in a beam at CERN. The total raw data volume that is slated to be collected during the scheduled 3-month beam run is estimated to be inmore » excess of 2.5 PB for each detector. This data volume will require that the protoDUNE experiment carefully design the DAQ, data handling and data quality monitoring systems to be capable of dealing with challenges inherent with peta-scale data management while simultaneously fulfilling the requirements of disseminating the data to a worldwide collaboration and DUNE associated computing sites. Here in this paper, we present our approach to solving these problems by leveraging the design, expertise and components created for the LHC and Intensity Frontier experiments into a unified architecture that is capable of meeting the needs of protoDUNE.« less
NASA Astrophysics Data System (ADS)
Hartini, S.; Letsoin, F.; Kristijanto, A. I.
2018-04-01
Recently, using of productive liquid fertilizer assumed as a proper and practical fertilizer for plant productivity purposes. Various ways of enrichment of liquid fertilizer were done to achieve certain quality. The purpose of this research was to determine the proper additional formulation in the process of making productive liquid fertilizer based on the various concentration of EM4 as well as comparated the result with SNI. Liquid tempe waste were collected from some tempe industries at Sidorejo Kidul village, Tingkir district, Salatiga. The concentration of EM4 which were added to the tempe wastewater are 0%; 0.20%; 0.40%; 0.60%; 0.80%; 1.00% respectively. The pH, temperature, C total, N total, C/N ratio, and PO4 3- were measured. Data was analyzed by using Randomize Completely Block Design (RCBD) with 6 treatments and 4 replications. Comparison between the average, the Honestly Significance Deference (HSD) 5% was used. The results showed that the addition of EM4 indicated there were a significant progress. Moreover, the most effective formula to increase the quality of productive liquid fertilizer from liquid waste tempe was found in addition of 1.00% EM4 with the gained analysis value for the C total, N total, C/N ratio, and degree of PO4 3- as follows : 4.395 ± 1.034%; 1.470 ± 0.081%; 3.01 ± 0.756; 685.28 ± 70.44 ppm . Associated with the need fulfillment of SNI hence can be concluded that result of Productive Liquid Fertilizer (PLF) from liquid waste tempe successfully fulfill SNI of liquid fertilizer for pH parameter and total N, only.
NASA Technical Reports Server (NTRS)
1975-01-01
An abbreviated version of the conclusions dealing with the safety implications of using liquid fluorinated oxidizers on space shuttle launched spacecraft was presented. The complete version was presented in volume 1.
National Institute of Standards and Technology Data Gateway
SRD 106 IUPAC-NIST Solubility Database (Web, free access) These solubilities are compiled from 18 volumes (Click here for List) of the International Union for Pure and Applied Chemistry(IUPAC)-NIST Solubility Data Series. The database includes liquid-liquid, solid-liquid, and gas-liquid systems. Typical solvents and solutes include water, seawater, heavy water, inorganic compounds, and a variety of organic compounds such as hydrocarbons, halogenated hydrocarbons, alcohols, acids, esters and nitrogen compounds. There are over 67,500 solubility measurements and over 1800 references.
Densities of Pb-Sn alloys during solidification
NASA Technical Reports Server (NTRS)
Poirier, D. R.
1988-01-01
Data for the densities and expansion coefficients of solid and liquid alloys of the Pb-Sn system are consolidated in this paper. More importantly, the data are analyzed with the purpose of expressing either the density of the solid or of the liquid as a function of its composition and temperature. In particular, the densities of the solid and of the liquid during dendritic solidification are derived. Finally, the solutal and thermal coefficients of volume expansion for the liquid are given as functions of temperature and composition.
Absorbance and fluorometric sensing with capillary wells microplates.
Tan, Han Yen; Cheong, Brandon Huey-Ping; Neild, Adrian; Liew, Oi Wah; Ng, Tuck Wah
2010-12-01
Detection and readout from small volume assays in microplates are a challenge. The capillary wells microplate approach [Ng et al., Appl. Phys. Lett. 93, 174105 (2008)] offers strong advantages in small liquid volume management. An adapted design is described and shown here to be able to detect, in a nonimaging manner, fluorescence and absorbance assays minus the error often associated with meniscus forming at the air-liquid interface. The presence of bubbles in liquid samples residing in microplate wells can cause inaccuracies. Pipetting errors, if not adequately managed, can result in misleading data and wrong interpretations of assay results; particularly in the context of high throughput screening. We show that the adapted design is also able to detect for bubbles and pipetting errors during actual assay runs to ensure accuracy in screening.
Cultivation of Microalgae Chlorella sp on Fresh Water and Waste Water of Tofu Industry
NASA Astrophysics Data System (ADS)
Widayat; Philia, John; Wibisono, Jessica
2018-02-01
Chlorella sp. is a microalgae that potential for food supplement, pharmaceuticals, animal feed, aqua culture and cosmetics. Chlorella sp. commonly growth in sea water. Indonesia as a producer of tofu generated more liquid waste. Nutrient that contained in the tofu wastewater are very useful for the production of microalgae. Cultivation carried out for 7 days at different percent volume of tofu liquid waste showed that the more volume of tofu liquid waste make them longer process decipherment of polymer compounds in the waste, that's make the growth rate of Chlorella sp. are slowness. Variable of10%V has the fastest growth rate. While, 90% v/v variable has the highest concentration of algae. It shows that Chlorella sp. better to grows in tofu wastewater than seawater.
49 CFR 173.150 - Exceptions for Class 3 (flammable and combustible liquids).
Code of Federal Regulations, 2013 CFR
2013-10-01
... subchapter if the alcoholic beverage: (i) Contains 24 percent or less alcohol by volume; (ii) Is contained in... requirements of this subchapter if the alcoholic beverage: (i) Contains 24 percent or less alcohol by volume...% alcohol by volume when in unopened retail packagings not exceeding 5 liters (1.3 gallons) carried in carry...
LWC and Temperature Effects on Ice Accretion Formation on Swept Wings at Glaze Ice Conditions
NASA Technical Reports Server (NTRS)
Vargas, Mario; Reshotko, Eli
2000-01-01
An experiment was conducted to study the effect of liquid water content and temperature on the critical distance in ice accretion formation on swept wings at glaze ice conditions. The critical distance is defined as the distance from the attachment line to tile beginning of the zone where roughness elements develop into glaze ice feathers. A baseline case of 150 mph, 25 F, 0.75 g/cu m. Cloud Liquid Water Content (LWC) and 20 micrometers in Water Droplet Median Volume Diameter (MVD) was chosen. Icing runs were performed on a NACA 0012 swept wing tip at 150 mph and MVD of 20 micrometers for liquid water contents of 0.5 g/cu m, 0.75 g/cu m, and 1.0 g/cu m, and for total temperatures of 20 F, 25 F and 30 F. At each tunnel condition, the sweep angle was changed from 0 deg to 45 deg in 5 deg increments. Casting data, ice shape tracings, and close-up photographic data were obtained. The results showed that decreasing the LWC to 0.5 g/cu m decreases the value of the critical distance at a given sweep angle compared to the baseline case, and starts the formation of complete scallops at 30 sweep angle. Increasing the LWC to 1.0 g/cu m increases the value of the critical distance compared to the baseline case, the critical distance remains always above 0 millimeters and complete scallops are not formed. Decreasing the total temperature to 20 F decreases the critical distance with respect to the baseline case and formation of complete scallops begins at 25 deg sweep angle. When the total temperature is increased to 30 F, bumps covered with roughness elements appear on the ice accretion at 25 deg and 30 deg sweep angles, large ice structures appear at 35 deg and 40 deg sweep angles, and complete scallops are formed at 45 deg sweep angle.
Ionic Liquid-Doped Gel Polymer Electrolyte for Flexible Lithium-Ion Polymer Batteries
Zhang, Ruisi; Chen, Yuanfen; Montazami, Reza
2015-01-01
Application of gel polymer electrolytes (GPE) in lithium-ion polymer batteries can address many shortcomings associated with liquid electrolyte lithium-ion batteries. Due to their physical structure, GPEs exhibit lower ion conductivity compared to their liquid counterparts. In this work, we have investigated and report improved ion conductivity in GPEs doped with ionic liquid. Samples containing ionic liquid at a variety of volume percentages (vol %) were characterized for their electrochemical and ionic properties. It is concluded that excess ionic liquid can damage internal structure of the batteries and result in unwanted electrochemical reactions; however, samples containing 40–50 vol % ionic liquid exhibit superior ionic properties and lower internal resistance compared to those containing less or more ionic liquids.
Jenke, Christoph; Pallejà Rubio, Jaume; Kibler, Sebastian; Häfner, Johannes; Richter, Martin; Kutter, Christoph
2017-01-01
With the combination of micropumps and flow sensors, highly accurate and secure closed-loop controlled micro dosing systems for liquids are possible. Implementing a single stroke based control mode with piezoelectrically driven micro diaphragm pumps can provide a solution for dosing of volumes down to nanoliters or variable average flow rates in the range of nL/min to μL/min. However, sensor technologies feature a yet undetermined accuracy for measuring highly pulsatile micropump flow. Two miniaturizable in-line sensor types providing electrical readout—differential pressure based flow sensors and thermal calorimetric flow sensors—are evaluated for their suitability of combining them with mircopumps. Single stroke based calibration of the sensors was carried out with a new method, comparing displacement volumes and sensor flow volumes. Limitations of accuracy and performance for single stroke based flow control are described. Results showed that besides particle robustness of sensors, controlling resistive and capacitive damping are key aspects for setting up reproducible and reliable liquid dosing systems. Depending on the required average flow or defined volume, dosing systems with an accuracy of better than 5% for the differential pressure based sensor and better than 6.5% for the thermal calorimeter were achieved. PMID:28368344
NASA Astrophysics Data System (ADS)
García-Florentino, Cristina; Maguregui, Maite; Marguí, Eva; Torrent, Laura; Queralt, Ignasi; Madariaga, Juan Manuel
2018-05-01
In this work, a Total Reflection X-ray fluorescence (TXRF) spectrometry based quantitative methodology for elemental characterization of liquid extracts and solids belonging to old building materials and their degradation products from a building of the beginning of 20th century with a high historic cultural value in Getxo, (Basque Country, North of Spain) is proposed. This quantification strategy can be considered a faster methodology comparing to traditional Energy or Wavelength Dispersive X-ray fluorescence (ED-XRF and WD-XRF) spectrometry based methodologies or other techniques such as Inductively Coupled Plasma Mass Spectrometry (ICP-MS). In particular, two kinds of liquid extracts were analysed: (i) water soluble extracts from different mortars and (ii) acid extracts from mortars, black crusts, and calcium carbonate formations. In order to try to avoid the acid extraction step of the materials and their degradation products, it was also studied the TXRF direct measurement of the powdered solid suspensions in water. With this aim, different parameters such as the deposition volume and the measuring time were studied for each kind of samples. Depending on the quantified element, the limits of detection achieved with the TXRF quantitative methodologies for liquid extracts and solids were set around 0.01-1.2 and 2-200 mg/L respectively. The quantification of K, Ca, Ti, Mn, Fe, Zn, Rb, Sr, Sn and Pb in the liquid extracts was proved to be a faster alternative to other more classic quantification techniques (i.e. ICP-MS), accurate enough to obtain information about the composition of the acidic soluble part of the materials and their degradation products. Regarding the solid samples measured as suspensions, it was quite difficult to obtain stable and repetitive suspensions affecting in this way the accuracy of the results. To cope with this problem, correction factors based on the quantitative results obtained using ED-XRF were calculated to improve the accuracy of the TXRF results.
Quantifying intermolecular interactions of ionic liquids using cohesive energy densities.
Lovelock, Kevin R J
2017-12-01
For ionic liquids (ILs), both the large number of possible cation + anion combinations and their ionic nature provide a unique challenge for understanding intermolecular interactions. Cohesive energy density, ced , is used to quantify the strength of intermolecular interactions for molecular liquids, and is determined using the enthalpy of vaporization. A critical analysis of the experimental challenges and data to obtain ced for ILs is provided. For ILs there are two methods to judge the strength of intermolecular interactions, due to the presence of multiple constituents in the vapour phase of ILs. Firstly, ced IP , where the ionic vapour constituent is neutral ion pairs, the major constituent of the IL vapour. Secondly, ced C+A , where the ionic vapour constituents are isolated ions. A ced IP dataset is presented for 64 ILs. For the first time an experimental ced C+A , a measure of the strength of the total intermolecular interaction for an IL, is presented. ced C+A is significantly larger for ILs than ced for most molecular liquids, reflecting the need to break all of the relatively strong electrostatic interactions present in ILs. However, the van der Waals interactions contribute significantly to IL volatility due to the very strong electrostatic interaction in the neutral ion pair ionic vapour. An excellent linear correlation is found between ced IP and the inverse of the molecular volume. A good linear correlation is found between IL ced IP and IL Gordon parameter (which are dependent primarily on surface tension). ced values obtained through indirect methods gave similar magnitude values to ced IP . These findings show that ced IP is very important for understanding IL intermolecular interactions, in spite of ced IP not being a measure of the total intermolecular interactions of an IL. In the outlook section, remaining challenges for understanding IL intermolecular interactions are outlined.
Quantifying intermolecular interactions of ionic liquids using cohesive energy densities
2017-01-01
For ionic liquids (ILs), both the large number of possible cation + anion combinations and their ionic nature provide a unique challenge for understanding intermolecular interactions. Cohesive energy density, ced, is used to quantify the strength of intermolecular interactions for molecular liquids, and is determined using the enthalpy of vaporization. A critical analysis of the experimental challenges and data to obtain ced for ILs is provided. For ILs there are two methods to judge the strength of intermolecular interactions, due to the presence of multiple constituents in the vapour phase of ILs. Firstly, cedIP, where the ionic vapour constituent is neutral ion pairs, the major constituent of the IL vapour. Secondly, cedC+A, where the ionic vapour constituents are isolated ions. A cedIP dataset is presented for 64 ILs. For the first time an experimental cedC+A, a measure of the strength of the total intermolecular interaction for an IL, is presented. cedC+A is significantly larger for ILs than ced for most molecular liquids, reflecting the need to break all of the relatively strong electrostatic interactions present in ILs. However, the van der Waals interactions contribute significantly to IL volatility due to the very strong electrostatic interaction in the neutral ion pair ionic vapour. An excellent linear correlation is found between cedIP and the inverse of the molecular volume. A good linear correlation is found between IL cedIP and IL Gordon parameter (which are dependent primarily on surface tension). ced values obtained through indirect methods gave similar magnitude values to cedIP. These findings show that cedIP is very important for understanding IL intermolecular interactions, in spite of cedIP not being a measure of the total intermolecular interactions of an IL. In the outlook section, remaining challenges for understanding IL intermolecular interactions are outlined. PMID:29308254
Ishibashi, Ryo; Mawatari, Kazuma; Kitamori, Takehiko
2012-04-23
The rapidly developing interest in nanofluidic analysis, which is used to examine liquids ranging in amounts from the attoliter to the femtoliter scale, correlates with the recent interest in decreased sample amounts, such as in the field of single-cell analysis. For general nanofluidic analysis, the fact that a pressure-driven flow does not limit the choice of solvents (aqueous or organic) is important. This study shows the first pressure-driven liquid chromatography technique that enables separation of atto- to femtoliter sample volumes, with a high separation efficiency within a few seconds. The apparent diffusion coefficient measurement of the unretentive sample suggests that there is no increase in the viscosity of toluene in the extended nanospace, unlike in aqueous solvents. Evaluation of the normal phase separation, therefore, should involve only the examination of the effect of the small size of the extended nanospace. Compared to a conventionally packed high-performance liquid chromatography column, the separation here results in a faster separation (4 s) by 2 orders of magnitude, a smaller injection volume (10(0) fL) by 9 orders, and a higher separation efficiency (440,000 plates/m) by 1 order. Moreover, the separation behavior agrees with the theory showing that this high efficiency was due to the small and controlled size of the separation channel, where the diffusion through the channel depth direction is fast enough to be neglected. Our chip-based platform should allow direct and real-time analysis or screening of ultralow volume of sample. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Technical Reports Server (NTRS)
Moran, Matthew E.; Nyland, Ted W.
1992-01-01
A total of 38 hydrogen no-vent fill tests were performed in this test series using various size spray nozzles and a spray bar with different hole sizes in a 5 cubic foot receiver tank. Fill levels of 90 percent by volume or greater were achieved in 26 of the tests while maintaining a receiver tank pressure below 30 psia. Spray nozzles were mounted at the top of the tank, whereas, the spray bar was centered in the tank axially. The spray nozzle no-vent fills demonstrated tank pressure and temperature responses comparable to previous test series. Receiver tank pressure responses for the spray bar configuration were similar to the spray nozzle tests with the pressure initially rising rapidly, then leveling off as vapor condenses onto the discharging liquid streams, and finally ramping up near the end of the test due to ullage compression. Both liquid injection techniques tested were capable of filling the receiver tank to 90 percent under variable test conditions. Comparisons between the spray nozzle and spray bar configurations for well matched test conditions indicate the spray nozzle injection technique is more effective in minimizing the receiving tank pressure throughout a no-vent fill compared to the spray bar under normal gravity conditions.
Meso-Scale Wetting of Paper Towels
NASA Astrophysics Data System (ADS)
Abedsoltan, Hossein
In this study, a new experimental approach is proposed to investigate the absorption properties of some selected retail paper towels. The samples were selected from two important manufacturing processes, conventional wet pressing (CWP) considered value products, and through air drying (TAD) considered as high or premium products. The tested liquids were water, decane, dodecane, and tetradecane with the total volumes in micro-liter range. The method involves the point source injection of liquid with different volumetric flowrates, in the nano-liter per second range. The local site for injection was chosen arbitrarily on the sample surface. The absorption process was monitored and recorded as the liquid advances, with two distinct imaging system methods, infrared imaging and optical imaging. The microscopic images were analyzed to calculate the wetted regions during the absorption test, and the absorption diagrams were generated. These absorption diagrams were dissected to illustrate the absorption phenomenon, and the absorption properties of the samples. The local (regional) absorption rates were computed for Mardi Gras and Bounty Basic as the representative samples for CWP and TAD, respectively in order to be compared with the absorption capacity property of these two samples. Then, the absorption capacity property was chosen as an index factor to compare the absorption properties of all the tested paper towels.
An Example of Branching in a Variational Problem.
ERIC Educational Resources Information Center
Darbro, Wesley
1978-01-01
Investigates the shape a liquid takes, due to its surface tension while suspended upon a wire frame in zero-g, using Lagrange multipliers. Shows how the configuration of soap films so bounded are dependent upon the volume of liquid trapped in the films. (Author/GA)
Wiegmann, Vincent; Martinez, Cristina Bernal; Baganz, Frank
2018-04-24
Establish a method to indirectly measure evaporation in microwell-based cell culture systems and show that the proposed method allows compensating for liquid losses in fed-batch processes. A correlation between evaporation and the concentration of Na + was found (R 2 = 0.95) when using the 24-well-based miniature bioreactor system (micro-Matrix) for a batch culture with GS-CHO. Based on these results, a method was developed to counteract evaporation with periodic water additions based on measurements of the Na + concentration. Implementation of this method resulted in a reduction of the relative liquid loss after 15 days of a fed-batch cultivation from 36.7 ± 6.7% without volume corrections to 6.9 ± 6.5% with volume corrections. A procedure was established to indirectly measure evaporation through a correlation with the level of Na + ions in solution and deriving a simple formula to account for liquid losses.
Formulation design for optimal high-shear wet granulation using on-line torque measurements.
Cavinato, Mauro; Bresciani, Massimo; Machin, Marianna; Bellazzi, Guido; Canu, Paolo; Santomaso, Andrea C
2010-03-15
An alternative procedure for achieving formulation design in a high-shear wet granulation process has been developed. Particularly, a new formulation map has been proposed which describes the onset of a significant granule growth as a function of the formulation variables (diluent, dry and liquid binder). Granule growth has been monitored using on-line impeller torque and evaluated as changes in granule particle size distribution with respect to the dry formulation. It is shown how the onset of granule growth is denoted by an abrupt increase in the torque value requires the amount of binder liquid added to be greater than a certain threshold that is identified here as 'minimum liquid volume'. This minimum liquid volume is determined as a function of dry binder type, amount, hygroscopicity and particle size distribution of diluent. It is also demonstrated how this formulation map can be constructed from independent measurements of binder glass transition temperatures using a static humidity conditioning system. 2009 Elsevier B.V. All rights reserved.
Alothman, Zeid A; Al-Shaalan, Nora H; Habila, Mohamed A; Unsal, Yunus E; Tuzen, Mustafa; Soylak, Mustafa
2015-02-01
A dispersive liquid-liquid microextraction procedure for lead(II) as its 5-(4-dimethylaminobenzylidene) rhodanine complex has been established prior to its microsampling flame atomic absorption spectrometric determination. The influences of various analytical parameters including pH, solvent type and volume, dispersive solvent type and volume, 5-(4-dimethylaminobenzylidene) rhodanine amount, salt effect, and centrifugation time and speed were investigated. The effects of certain alkali, alkaline earth, and transition metal ions on the quantitative extraction of lead(II) were also studied. Quantitative recoveries were obtained at pH 6. The enrichment factor was calculated as 125. The detection limit for lead is 1.1 μg/L. The accuracy of the method was tested with the additions recovery test and analysis of the standard reference materials (SPS-WW2 waste water, NIST SRM 1515 apple leaves, and TMDA-51.3 fortified water). Applications of the present procedure were tested by analyzing water and food samples.
Snitkjær, Pia; Ryapushkina, Julia; Skovenborg, Erik; Astrup, Arne; Bech, Lene Mølskov; Jensen, Morten Georg; Risbo, Jens
2017-09-01
To obtain an understanding of the ethanol loss during cooking of liquid foods containing alcoholic beverages, ethanol concentration was measured as a function of time and remaining volume in meat stocks prepared with wine and beer. A mathematical model describing the decline in volatile compounds during heating of simple liquid foods was derived. The experimental results and the model show that concentration of ethanol at any given time is determined by the initial concentration and a power law function of the remaining volume fraction. The power law function is found to be independent of factors like pot dimensions and temperature. When using a lid to cover the pot during cooking, the model was still valid but the ethanol concentrations decreased more steeply, corresponding to a higher exponent. The results provide a theoretical and empirical guideline for predicting the ethanol concentration in cooked liquid foods. Copyright © 2017 Elsevier Ltd. All rights reserved.
Swiety-Pospiech, A; Wojnarowska, Z; Hensel-Bielowka, S; Pionteck, J; Paluch, M
2013-05-28
Broadband dielectric spectroscopy and pressure-temperature-volume methods are employed to investigate the effect of hydrostatic pressure on the conductivity relaxation time (τσ), both in the supercooled and glassy states of protic ionic liquid lidocaine hydrochloride monohydrate. Due to the decoupling between the ion conductivity and structural dynamics, the characteristic change in behavior of τσ(T) dependence, i.e., from Vogel-Fulcher-Tammann-like to Arrhenius-like behavior, is observed. This crossover is a manifestation of the liquid-glass transition of lidocaine HCl. The similar pattern of behavior was also found for pressure dependent isothermal measurements. However, in this case the transition from one simple volume activated law to another was noticed. Additionally, by analyzing the changes of conductivity relaxation times during isothermal densification of the sample, it was found that compression enhances the decoupling of electrical conductivity from the structural relaxation. Herein, we propose a new parameter, dlogRτ∕dP, to quantify the pressure sensitivity of the decoupling phenomenon. Finally, the temperature and volume dependence of τσ is discussed in terms of thermodynamic scaling concept.
Dotette: Programmable, high-precision, plug-and-play droplet pipetting.
Fan, Jinzhen; Men, Yongfan; Hao Tseng, Kuo; Ding, Yi; Ding, Yunfeng; Villarreal, Fernando; Tan, Cheemeng; Li, Baoqing; Pan, Tingrui
2018-05-01
Manual micropipettes are the most heavily used liquid handling devices in biological and chemical laboratories; however, they suffer from low precision for volumes under 1 μ l and inevitable human errors. For a manual device, the human errors introduced pose potential risks of failed experiments, inaccurate results, and financial costs. Meanwhile, low precision under 1 μ l can cause severe quantification errors and high heterogeneity of outcomes, becoming a bottleneck of reaction miniaturization for quantitative research in biochemical labs. Here, we report Dotette, a programmable, plug-and-play microfluidic pipetting device based on nanoliter liquid printing. With automated control, protocols designed on computers can be directly downloaded into Dotette, enabling programmable operation processes. Utilizing continuous nanoliter droplet dispensing, the precision of the volume control has been successfully improved from traditional 20%-50% to less than 5% in the range of 100 nl to 1000 nl. Such a highly automated, plug-and-play add-on to existing pipetting devices not only improves precise quantification in low-volume liquid handling and reduces chemical consumptions but also facilitates and automates a variety of biochemical and biological operations.
Ferry, Barbara; Gifu, Elena-Patricia; Sandu, Ioana; Denoroy, Luc; Parrot, Sandrine
2014-03-01
Electrochemical methods are very often used to detect catecholamine and indolamine neurotransmitters separated by conventional reverse-phase high performance liquid chromatography (HPLC). The present paper presents the development of a chromatographic method to detect monoamines present in low-volume brain dialysis samples using a capillary column filled with sub-2μm particles. Several parameters (repeatability, linearity, accuracy, limit of detection) for this new ultrahigh performance liquid chromatography (UHPLC) method with electrochemical detection were examined after optimization of the analytical conditions. Noradrenaline, adrenaline, serotonin, dopamine and its metabolite 3-methoxytyramine were separated in 1μL of injected sample volume; they were detected above concentrations of 0.5-1nmol/L, with 2.1-9.5% accuracy and intra-assay repeatability equal to or less than 6%. The final method was applied to very low volume dialysates from rat brain containing monoamine traces. The study demonstrates that capillary UHPLC with electrochemical detection is suitable for monitoring dialysate monoamines collected at high sampling rate. Copyright © 2014 Elsevier B.V. All rights reserved.
COAL CONVERSION CONTROL TECHNOLOGY. VOLUME I. ENVIRONMENTAL REGULATIONS; LIQUID EFFLUENTS
This volume is the product of an information-gathering effort relating to coal conversion process streams. Available and developing control technology has been evaluated in view of the requirements of present and proposed federal, state, regional, and international environmental ...