Nieskoski, Michael D; Marra, Kayla; Gunn, Jason R; Kanick, Stephen C; Doyley, Marvin M; Hasan, Tayyaba; Pereira, Stephen P; Stuart Trembly, B; Pogue, Brian W
2017-06-01
Elevated total tissue pressure (TTP) in pancreatic adenocarcinoma is often associated with stress applied by cellular proliferation and hydrated hyaluronic acid osmotic swelling; however, the causal roles of collagen in total tissue pressure have yet to be clearly measured. This study illustrates one direct correlation between total tissue pressure and increased deposition of collagen within the tissue matrix. This observation comes from a new modification to a conventional piezoelectric pressure catheter, used to independently separate and quantify total tissue pressure, solid stress (SS), and interstitial fluid pressure (IFP) within the same tumor location, thereby clarifying the relationship between these parameters. Additionally, total tissue pressure shows a direct correlation with verteporfin uptake, demonstrating the impediment of systemically delivered molecules with increased tissue hypertension.
NASA Astrophysics Data System (ADS)
Chu, Huaqiang; Gu, Mingyan; Consalvi, Jean-Louis; Liu, Fengshan; Zhou, Huaichun
2016-03-01
The effects of total pressure on gas radiation heat transfer are investigated in 1D parallel plate geometry containing isothermal and homogeneous media and an inhomogeneous and non-isothermal CO2-H2O mixture under conditions relevant to oxy-fuel combustion using the line-by-line (LBL), statistical narrow-band (SNB), statistical narrow-band correlated-k (SNBCK), weighted-sum-of-grey-gases (WSGG), and full-spectrum correlated-k (FSCK) models. The LBL calculations were conducted using the HITEMP2010 and CDSD-1000 databases and the LBL results serve as the benchmark solution to evaluate the accuracy of the other models. Calculations of the SNB, SNBCK, and FSCK were conducted using both the 1997 EM2C SNB parameters and their recently updated 2012 parameters to investigate how the SNB model parameters affect the results under oxy-fuel combustion conditions at high pressures. The WSGG model considered is the recently developed one by Bordbar et al. [19] for oxy-fuel combustion based on LBL calculations using HITEMP2010. The total pressure considered ranges from 1 up to 30 atm. The total pressure significantly affects gas radiation transfer primarily through the increase in molecule number density and only slightly through spectral line broadening. Using the 1997 EM2C SNB model parameters the accuracy of SNB and SNBCK is very good and remains essentially independent of the total pressure. When using the 2012 EM2C SNB model parameters the SNB and SNBCK results are less accurate and their error increases with increasing the total pressure. The WSGG model has the lowest accuracy and the best computational efficiency among the models investigated. The errors of both WSGG and FSCK using the 2012 EM2C SNB model parameters increase when the total pressure is increased from 1 to 10 atm, but remain nearly independent of the total pressure beyond 10 atm. When using the 1997 EM2C SNB model parameters the accuracy of FSCK only slightly decreases with increasing the total pressure.
NASA Technical Reports Server (NTRS)
Hirsch, David; Williams, Jim; Beeson, Harold
2006-01-01
Spacecraft materials selection is based on an upward flammability test conducted in a quiescent environment in the highest-expected oxygen-concentration environment. However, NASA s advanced space exploration program is anticipating using various habitable environments. Because limited data is available to support current program requirements, a different test logic is suggested to address these expanded atmospheric environments through the determination of materials self-extinguishment limits. This paper provides additional pressure effects data on oxygen concentration and partial pressure self-extinguishment limits under quiescent conditions. For the range of total pressures tested, the oxygen concentration and oxygen partial pressure flammability thresholds show a near linear function of total pressure. The oxygen concentration/oxygen partial pressure flammability thresholds depend on the total pressure and appear to increase with increasing oxygen concentration (and oxygen partial pressure). For the Constellation Program, the flammability threshold information will allow NASA to identify materials with increased flammability risk because of oxygen concentration and total pressure changes, minimize potential impacts, and allow for development of sound requirements for new spacecraft and extraterrestrial landers and habitats.
Sewage sludge disintegration by high-pressure homogenization: a sludge disintegration model.
Zhang, Yuxuan; Zhang, Panyue; Ma, Boqiang; Wu, Hao; Zhang, Sheng; Xu, Xin
2012-01-01
High-pressure homogenization (HPH) technology was applied as a pretreatment to disintegrate sewage sludge. The effects of homogenization pressure, homogenization cycle number, and total solid content on sludge disintegration were investigated. The sludge disintegration degree (DD(COD)), protein concentration, and polysaccharide concentration increased with the increase of homogenization pressure and homogenization cycle number, and decreased with the increase of sludge total solid (TS) content. The maximum DD(COD) of 43.94% was achieved at 80 MPa with four homogenization cycles for a 9.58 g/L TS sludge sample. A HPH sludge disintegration model of DD(COD) = kNaPb was established by multivariable linear regression to quantify the effects of homogenization parameters. The homogenization cycle exponent a and homogenization pressure exponent b were 0.4763 and 0.7324 respectively, showing that the effect of homogenization pressure (P) was more significant than that of homogenization cycle number (N). The value of the rate constant k decreased with the increase of sludge total solid content. The specific energy consumption increased with the increment of sludge disintegration efficiency. Lower specific energy consumption was required for higher total solid content sludge.
Buckow, Roman; Kastell, Anja; Terefe, Netsanet Shiferaw; Versteeg, Cornelis
2010-09-22
The degradation kinetics of total anthocyanins in blueberry (Vaccinium myrtillus) juice were studied during thermal processing by treatment at selected temperatures (60-121 °C) and combined high pressure-temperature processing (100-700 MPa, 40-121 °C). Anthocyanin stability was also studied for several of these treatments during storage at 4, 25, and 40 °C. Both pressure and temperature increased d, the degradation rate of total anthocyanins in blueberry juice, meaning that at constant temperature, anthocyanins were more rapidly degraded with increasing pressure. For example, 32% degradation of anthocyanins was observed after 20 min heating at 100 °C and atmospheric pressure, whereas at 100 °C and 600 MPa, approximately 50% of total anthocyanins were lost. Degradation of anthocyanins was significantly accelerated with increasing storage temperatures. Combined pressure-temperature treatment of pasteurized juice led to a slightly faster degradation of total anthocyanins during storage compared to heat treatments at ambient pressure. Degradation of anthocyanins was best described by a 1.4th-order reaction at all conditions investigated. A mathematical model describing the degradation of blueberry anthocyanins in juice as a function of pressure, temperature, and treatment time is presented.
Chen, Xiao-Tian; Yang, Song; Yang, Ya-Ming; Zhao, Hai-Long; Chen, Yan-Chun; Zhao, Xiang-Hai; Wen, Jin-Bo; Tian, Yuan-Rui; Yan, Wei-Li; Shen, Chong
2017-11-04
Total bilirubin is beneficial for protecting cardiovascular diseases in adults. The authors aimed to investigate the association of total bilirubin, red blood cell, and hemoglobin levels with the prevalence of high blood pressure in children and adolescents. A total of 3776 students (aged from 6 to 16 years old) were examined using cluster sampling. Pre-high blood pressure and high blood pressure were respectively defined as the point of 90th and 95th percentiles based on the Fourth Report on the Diagnosis, Evaluation, and Treatment of High Blood Pressure in Children and Adolescents. Both systolic and diastolic blood pressure were standardized into z-scores. Peripheral total bilirubin, red blood cell and hemoglobin levels were significantly correlated with age, and also varied with gender. Peripheral total bilirubin was negatively correlated with systolic blood pressure in 6- and 9-year-old boys, whilst positively correlated with diastolic blood pressure in the 12-year-old boys and 13- to 15-year-old girls (p<0.05). Higher levels of red blood cell and hemoglobin were observed in pre-high blood pressure and high blood pressure students when compared with their normotensive peers (p<0.01). The increases in red blood cell and hemoglobin were significantly associated with high blood pressure after adjusting for confounding factors. The ORs (95% CI) of each of the increases were 2.44 (1.52-3.92) and 1.04 (1.03-1.06), respectively. No statistical association between total bilirubin and high blood pressure was observed (p>0.05). Total bilirubin could be weakly correlated with both systolic and diastolic blood pressure, as correlations varied with age and gender in children and adolescents; in turn, the increased levels of red blood cell and hemoglobin are proposed to be positively associated with the prevalence of high blood pressure. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
S-Duct Engine Inlet Flow Control Using SDBD Plasma Streamwise Vortex Generators
NASA Astrophysics Data System (ADS)
Kelley, Christopher; He, Chuan; Corke, Thomas
2009-11-01
The results of a numerical simulation and experiment characterizing the performance of plasma streamwise vortex generators in controlling separation and secondary flow within a serpentine, diffusing duct are presented. A no flow control case is first run to check agreement of location of separation, development of secondary flow, and total pressure recovery between the experiment and numerical results. Upon validation, passive vane-type vortex generators and plasma streamwise vortex generators are implemented to increase total pressure recovery and reduce flow distortion at the aerodynamic interface plane: the exit of the S-duct. Total pressure recovery is found experimentally with a pitot probe rake assembly at the aerodynamic interface plane. Stagnation pressure distortion descriptors are also presented to show the performance increase with plasma streamwise vortex generators in comparison to the baseline no flow control case. These performance parameters show that streamwise plasma vortex generators are an effective alternative to vane-type vortex generators in total pressure recovery and total pressure distortion reduction in S-duct inlets.
Effects of nifedipine and captopril on vascular capacitance of ganglion-blocked anesthetized dogs.
Ogilvie, R I; Zborowska-Sluis, D
1990-03-01
The hemodynamic effects of nifedipine and captopril at doses producing similar reductions in arterial pressure were studied in pentobarbital-anesthetized ventilated dogs after splenectomy during ganglion blockade with hexamethonium. Mean circulatory filling pressure (Pmcf) was determined during transient circulatory arrest induced by acetylcholine at baseline circulating blood volumes and after increases of 5 and 10 mL/kg. Central blood volumes (pulmonary artery to aortic root) were determined from transit times, and separately determined cardiac outputs (right atrium to pulmonary artery) were estimated by thermodilution. Nifedipine (n = 5) increased Pmcf at all circulating blood volumes and reduced total vascular capacitance without a change in total vascular compliance. Central blood volume, right atrial pressure, and cardiac output were increased with induced increases in circulating blood volume. In contrast, captopril (n = 5) did not alter total vascular capacitance, central blood volume, right atrial pressure, or cardiac output at baseline or with increased circulating volume. Thus, at doses producing similar reductions in arterial pressure, nifedipine but not captopril increased venous return and cardiac output in ganglion-blocked dogs.
Rodrigues, Warren; Carr, Michelle; Ridout, Deborah; Carter, Katherine; Hulme, Sara Louise; Simmonds, Jacob; Elliott, Martin; Hoskote, Aparna; Burch, Michael; Brown, Kate L
2011-11-01
Single-center studies have failed to link modest increases in total donor ischemic time to mortality after pediatric orthotopic heart transplant. We aimed to investigate whether prolonged total donor ischemic time is linked to pediatric intensive care morbidity after orthotopic heart transplant. Retrospective cohort review. Tertiary pediatric transplant center in the United Kingdom. Ninety-three pediatric orthotopic heart transplants between 2002 and 2006. Total donor ischemic time was investigated for association with early post-orthotopic heart transplant hemodynamics and intensive care unit morbidities. Of 43 males and 50 females with median age 7.2 (interquartile range 2.2, 13.0) yrs, 62 (68%) had dilated cardiomyopathy, 20 (22%) had congenital heart disease, and nine (10%) had restrictive cardiomyopathy. The mean total donor ischemic time was 225.9 (sd 65.6) mins. In the first 24 hrs after orthotopic heart transplant, age-adjusted mean arterial blood pressure increased (p < .001), mean pulmonary arterial pressure fell (p = .012), but central venous pressure (p = .58) and left atrial pressure (p = .20) were unchanged. After adjustment for age, primary diagnosis, pre-orthotopic heart transplant mechanical support, and marginal donor factors, longer total donor ischemic time was significantly associated with lower mean arterial blood pressure (p < .001) in the first 24 hrs after orthotopic heart transplant, longer post-orthotopic heart transplant mechanical ventilation (p = .03), longer post-orthotopic heart transplant stay in the intensive care unit (p = .004), and longer post-orthotopic heart transplant stay in hospital (p = .02). Total donor ischemic time was not related to levels of mean pulmonary arterial pressure (p = .62), left atrial pressure (p = .38), or central venous pressure (p = .76) early after orthotopic heart transplant. Prolonged total donor ischemic time has an adverse effect on the donor organ, contributing to lower mean arterial blood pressure, as well as more prolonged ventilation and intensive care unit and hospital stays post-orthotopic heart transplant, reflecting increased morbidity.
Enhanced Performance of Streamline-Traced External-Compression Supersonic Inlets
NASA Technical Reports Server (NTRS)
Slater, John W.
2015-01-01
A computational design study was conducted to enhance the aerodynamic performance of streamline-traced, external-compression inlets for Mach 1.6. Compared to traditional external-compression, two-dimensional and axisymmetric inlets, streamline-traced inlets promise reduced cowl wave drag and sonic boom, but at the expense of reduced total pressure recovery and increased total pressure distortion. The current study explored a new parent flowfield for the streamline tracing and several variations of inlet design factors, including the axial displacement and angle of the subsonic cowl lip, the vertical placement of the engine axis, and the use of porous bleed in the subsonic diffuser. The performance was enhanced over that of an earlier streamline-traced inlet such as to increase the total pressure recovery and reduce total pressure distortion.
Hithamani, Gavirangappa; Srinivasan, Krishnapura
2014-12-01
Finger millet (Eleusine coracana) and pearl millet (Pennisetum glaucum) were evaluated for polyphenolic content and their bioaccessibility. Total polyphenols of native finger millet was 10.2mg/g which reduced by 50% after sprouting or pressure-cooking, while 12-19% reduction was seen after open-pan boiling. Total flavonoids of the grain reduced drastically on sprouting, pressure-cooking or open-pan boiling. Concentration of phenolic acids generally increased during sprouting and roasting of finger millet. Pressure cooking, open-pan boiling and microwave-heating reduced the bioaccessible polyphenols by 30-35%, while the same was increased by 67% by sprouting. Significant reduction of total polyphenols was observed in pressure-cooked, open-pan boiled and microwave-heated pearl millet. Concentration of sinapic and salicylic acids were highest phenolic acids of pearl millet. Total polyphenols reduced during sprouting and pressure-cooking. There was a 20% increase in the bioaccessible polyphenols after sprouting of pearl millet. Thus, sprouting and roasting provided more bioaccessible phenolics from these two common millets studied. Copyright © 2014. Published by Elsevier Ltd.
Zhou, Ji-Yin; Zhou, Shi-Wen; Du, Xiao-Huang; Zeng, Sheng-Ya
2012-09-28
Seabuckthorn (Hippophae rhamnoides L.) has been used to treat high altitude diseases. The effects of five-week treatment with total flavonoids of seabuckthorn (35, 70, 140 mg/kg, ig) on cobalt chloride (5.5 mg/kg, ip)- and hypobaric chamber (simulating 5,000 m)-induced high-altitude polycythemia in rats were measured. Total flavonoids decreased red blood cell number, hemoglobin, hematocrit, mean corpuscular hemoglobin levels, span of red blood cell electrophoretic mobility, aggregation index of red blood cell, plasma viscosity, whole blood viscosity, and increased deformation index of red blood cell, erythropoietin level in serum. Total flavonoids increased pH, pO₂, Sp(O₂), pCO₂ levels in arterial blood, and increased Na⁺, HCO₃⁻, Cl⁻, but decreased K⁺ concentrations. Total flavonoids increased mean arterial pressure, left ventricular systolic pressure, end-diastolic pressure, maximal rate of rise and decrease, decreased heart rate and protected right ventricle morphology. Changes in hemodynamic, hematologic parameters, and erythropoietin content suggest that administration of total flavonoids from seabuckthorn may be useful in the prevention of high altitude polycythaemia in rats.
Effect of ultra high pressure homogenization treatment on the bioactive compounds of soya milk.
Toro-Funes, N; Bosch-Fusté, J; Veciana-Nogués, M T; Vidal-Carou, M C
2014-01-01
Ultra high pressure homogenization (UHPH) is a useful novel technology to obtain safe and high-quality liquid foods. The effect of UHPH at 200 and 300 MPa in combination with different inlet temperatures (Tin) (55, 65 and 75 °C) on the bioactive compounds of soya milk was studied. Total phytosterols increased with the higher combination of pressure and temperature. The main phytosterol was β-sitosterol, followed by stigmasterol and campesterol. Total tocopherols in UHPH-treated soya milks decreased as the temperature and pressure increased. UHPH treatment also affected the different chemical forms of tocopherols. No biogenic amines were detected in any of the analyzed soya milks. Meanwhile, the polyamines SPD and SPM were found in all soya milks, being stable to the UHPH treatment. Total isoflavones increased with the higher combination of pressure and temperature. No differences in the isoflavone profile were found, with β-glucoside conjugates being the predominant form. Copyright © 2013 Elsevier Ltd. All rights reserved.
The biomechanical effect of increased valgus on total knee arthroplasty: a cadaveric study.
Bryant, Brandon J; Tilan, Justin U; McGarry, Michelle H; Takenaka, Nobuyuki; Kim, William C; Lee, Thay Q
2014-04-01
The effects of valgus load on cadaveric knees following total knee arthroplasty (TKA) were investigated using a custom testing system. TKAs were performed on 8 cadaveric knees and tested at 0°, 30°, and 60° knee flexion in both neutral and 5° valgus. Fuji pressure sensitive film was used to quantify contact areas and pressures and MCL strain was determined using a Microscribe digitizing system. Lateral tibiofemoral pressures increased (P < 0.05) at all knee flexion angles with valgus loading. Patellofemoral contact characteristics did not change significantly (P > 0.05). Significant increases in strain were observed along the anterior and posterior border of the MCL at all knee flexion angles. These findings suggest that valgus loading increases TKA joint contact pressures and MCL strain with increasing knee flexion which may increase implant instability. © 2014.
High methane natural gas/air explosion characteristics in confined vessel.
Tang, Chenglong; Zhang, Shuang; Si, Zhanbo; Huang, Zuohua; Zhang, Kongming; Jin, Zebing
2014-08-15
The explosion characteristics of high methane fraction natural gas were investigated in a constant volume combustion vessel at different initial conditions. Results show that with the increase of initial pressure, the peak explosion pressure, the maximum rate of pressure rise increase due to a higher amount (mass) of flammable mixture, which delivers an increased amount of heat. The increased total flame duration and flame development time result as a consequence of the higher amount of flammable mixture. With the increase of the initial temperature, the peak explosion pressures decrease, but the pressure increase during combustion is accelerated, which indicates a faster flame speed and heat release rate. The maximum value of the explosion pressure, the maximum rate of pressure rise, the minimum total combustion duration and the minimum flame development time is observed when the equivalence ratio of the mixture is 1.1. Additionally, for higher methane fraction natural gas, the explosion pressure and the maximum rate of pressure rise are slightly decreased, while the combustion duration is postponed. The combustion phasing is empirically correlated with the experimental parameters with good fitting performance. Furthermore, the addition of dilute gas significantly reduces the explosion pressure, the maximum rate of pressure rise and postpones the flame development and this flame retarding effect of carbon dioxide is stronger than that of nitrogen. Copyright © 2014 Elsevier B.V. All rights reserved.
Influence of mental stress on the plasma homocysteine level and blood pressure change in young men.
Sawai, Asuka; Ohshige, Kenji; Kura, Naoki; Tochikubo, Osamu
2008-04-01
Objective. This study aimed to determine whether mental stress influences the plasma total homocysteine level or blood pressure in young men. Method. Twenty-seven male university students were assigned to a normal blood pressure group (24-h systolic blood pressure <125 mmHg and diastolic blood pressure <75 mmHg; 13 subjects) or a high blood pressure group (24-h systolic blood pressure > or =125 mmHg, or 24-h diastolic blood pressure > or =75 mmHg; 14 subjects). Wearing an ambulatory blood pressure monitoring device, subjects rested for 30 minutes, underwent an arithmetic test for 15 minutes, and rested again for 15 minutes. Blood samples were taken before and after the test. Plasma total homocysteine levels were measured. Heart rate, blood pressure, and sympathovagal balance were determined during the test. Results. The mean total homocysteine level at rest in the high blood pressure group was slightly, but not significantly, higher than that in the normal blood pressure group. The resting total homocysteine level was significantly higher in subjects with parental history of hypertension than in those without (p < 0.01). Blood pressure, heart rate, and the plasma total homocysteine level were increased significantly by mental stress (p < 0.05). The change in total homocysteine correlated significantly with the changes in systolic blood pressure and sympathovagal balance (p < 0.05). Conclusion. Resting total homocysteine level was significantly higher in male students with a parental history of hypertension than in those without. It was shown that mental stress elevates heart rate, blood pressure, sympathovagal activity, and the plasma total homocysteine level in young men.
Lee, Hyun-Sun; Lee, Hyun Jung; Yu, Hyung Jo; Ju, Do Weon; Kim, Yoonsook; Kim, Chong-Tai; Kim, Chul-Jin; Cho, Yong-Jin; Kim, Namsoo; Choi, Sin-Yang; Suh, Hyung Joo
2011-06-01
To determine biomaterial components, the components must first be transferred into solution; thus extraction is the first step in biomaterial analysis. High hydrostatic pressure technology was used for ginsenoside extraction from ginseng roots. In the extraction of fresh and red ginseng, high hydrostatic pressure extraction (HHPE) was found to be more effective than heat extraction (HE). In fresh ginseng extraction under HHPE, total ginsenosides (1602.2 µg mL⁻¹) and ginsenoside metabolite (132.6 µg mL⁻¹) levels were slightly higher than those under HE (1259.0 and 78.7 µg mL⁻¹), respectively. In red ginseng, similar results indicated total ginsenoside and ginsenoside metabolite amounts according to the extraction methods. Most volatile compounds by HHPE were higher than by HE treatment. HHPE of red ginseng was conducted under four pressures: 0.1 MPa (1 atm), 30, 50, and 80 MPa. Total sugar, uronic acid, and polyphenol amounts increased until 30 MPa of pressure and then showed decreasing tendencies. Total ginsenoside and ginsenoside metabolite contents linearly increased with increasing pressure, and a maximum was reached at 80 MPa for the metabolites. HHPE used for red ginseng processing contributes to enhanced extraction efficiencies of functional materials such as ginsenosides through cell structure modification. Copyright © 2011 Society of Chemical Industry.
Effect of Jet-nozzle-expansion Ratio on Drag of Parabolic Afterbodies
NASA Technical Reports Server (NTRS)
Englert, Gerald W; Vargo, Donald J; Cubbison, Robert W
1954-01-01
The interaction of the flow from one convergent and two convergent-divergent nozzles on parabolic afterbodies was studied at free-stream Mach numbers of 2.0, 1.6, and 0.6 over a range of jet pressure ratio. The influence of the jet on boattail and base drag was very pronounced. Study of the total external afterbody drag values at supersonic speeds indicated that, over most of the high-pressure-ratio range, increasing the nozzle design expansion ratio increased the drag even though the boattail area was reduced. Increasing the pressure ratio tended to increase slightly the total-drag increment caused by angle-of-attack operation.
Effect of high hydrostatic pressure on overall quality parameters of watermelon juice.
Liu, Y; Zhao, X Y; Zou, L; Hu, X S
2013-06-01
High hydrostatic pressure as a kind of non-thermal processing might maintain the quality of thermo-sensitive watermelon juice. So, the effect of high hydrostatic pressure treatment on enzymes and quality of watermelon juice was investigated. After high hydrostatic pressure treatment, the activities of polyphenol oxidase, peroxidase, and pectin methylesterase of juice decreased significantly with the pressure (P < 0.05). Inactivation of polyphenol oxidase and peroxidase could be fitted by two-fraction model and that of pectin methylesterase could be described by first-order reaction model. Titratable acidity, pH, and total soluble solid of juice did not change significantly (P > 0.05). No significant difference was observed in lycopene and total phenolics after high hydrostatic pressure treatment when compared to the control (P > 0.05). Cloudiness and viscosity increased with pressure (P < 0.05) but did not change significantly with treatment time (P > 0.05). a*- and b*-value both unchanged after high hydrostatic pressure treatment (P > 0.05) while L*-value increased but the values had no significant difference among treated juices. Browning degree after high hydrostatic pressure treatment decreased with increase in pressure and treatment time (P < 0.05). Through the comparison of total color difference values, high hydrostatic pressure had little effect on color of juice. The results of this study demonstrated the efficacy of high hydrostatic pressure in inactivating enzymes and maintaining the quality of watermelon juice.
Blood pressure in early autosomal dominant polycystic kidney disease.
Schrier, Robert W; Abebe, Kaleab Z; Perrone, Ronald D; Torres, Vicente E; Braun, William E; Steinman, Theodore I; Winklhofer, Franz T; Brosnahan, Godela; Czarnecki, Peter G; Hogan, Marie C; Miskulin, Dana C; Rahbari-Oskoui, Frederic F; Grantham, Jared J; Harris, Peter C; Flessner, Michael F; Bae, Kyongtae T; Moore, Charity G; Chapman, Arlene B
2014-12-11
Hypertension is common in autosomal dominant polycystic kidney disease (ADPKD) and is associated with increased total kidney volume, activation of the renin-angiotensin-aldosterone system, and progression of kidney disease. In this double-blind, placebo-controlled trial, we randomly assigned 558 hypertensive participants with ADPKD (15 to 49 years of age, with an estimated glomerular filtration rate [GFR] >60 ml per minute per 1.73 m(2) of body-surface area) to either a standard blood-pressure target (120/70 to 130/80 mm Hg) or a low blood-pressure target (95/60 to 110/75 mm Hg) and to either an angiotensin-converting-enzyme inhibitor (lisinopril) plus an angiotensin-receptor blocker (telmisartan) or lisinopril plus placebo. The primary outcome was the annual percentage change in the total kidney volume. The annual percentage increase in total kidney volume was significantly lower in the low-blood-pressure group than in the standard-blood-pressure group (5.6% vs. 6.6%, P=0.006), without significant differences between the lisinopril-telmisartan group and the lisinopril-placebo group. The rate of change in estimated GFR was similar in the two medication groups, with a negative slope difference in the short term in the low-blood-pressure group as compared with the standard-blood-pressure group (P<0.001) and a marginally positive slope difference in the long term (P=0.05). The left-ventricular-mass index decreased more in the low-blood-pressure group than in the standard-blood-pressure group (-1.17 vs. -0.57 g per square meter per year, P<0.001); urinary albumin excretion was reduced by 3.77% with the low-pressure target and increased by 2.43% with the standard target (P<0.001). Dizziness and light-headedness were more common in the low-blood-pressure group than in the standard-blood-pressure group (80.7% vs. 69.4%, P=0.002). In early ADPKD, the combination of lisinopril and telmisartan did not significantly alter the rate of increase in total kidney volume. As compared with standard blood-pressure control, rigorous blood-pressure control was associated with a slower increase in total kidney volume, no overall change in the estimated GFR, a greater decline in the left-ventricular-mass index, and greater reduction in urinary albumin excretion. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases and others; HALT-PKD [Study A] ClinicalTrials.gov number, NCT00283686.).
Methyl mercury, but not inorganic mercury, associated with higher blood pressure during pregnancy.
Wells, Ellen M; Herbstman, Julie B; Lin, Yu Hong; Hibbeln, Joseph R; Halden, Rolf U; Witter, Frank R; Goldman, Lynn R
2017-04-01
Prior studies addressing associations between mercury and blood pressure have produced inconsistent findings; some of this may result from measuring total instead of speciated mercury. This cross-sectional study of 263 pregnant women assessed total mercury, speciated mercury, selenium, and n-3 polyunsaturated fatty acids in umbilical cord blood and blood pressure during labor and delivery. Models with a) total mercury or b) methyl and inorganic mercury were evaluated. Regression models adjusted for maternal age, race/ethnicity, prepregnancy body mass index, neighborhood income, parity, smoking, n-3 fatty acids and selenium. Geometric mean total, methyl, and inorganic mercury concentrations were 1.40µg/L (95% confidence interval: 1.29, 1.52); 0.95µg/L (0.84, 1.07); and 0.13µg/L (0.10, 0.17), respectively. Elevated systolic BP, diastolic BP, and pulse pressure were found, respectively, in 11.4%, 6.8%, and 19.8% of mothers. In adjusted multivariable models, a one-tertile increase of methyl mercury was associated with 2.83mmHg (0.17, 5.50) higher systolic blood pressure and 2.99mmHg (0.91, 5.08) higher pulse pressure. In the same models, an increase of one tertile of inorganic mercury was associated with -1.18mmHg (-3.72, 1.35) lower systolic blood pressure and -2.51mmHg (-4.49, -0.53) lower pulse pressure. No associations were observed with diastolic pressure. There was a non-significant trend of higher total mercury with higher systolic blood pressure. We observed a significant association of higher methyl mercury with higher systolic and pulse pressure, yet higher inorganic mercury was significantly associated with lower pulse pressure. These results should be confirmed with larger, longitudinal studies. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Stevens, C. H.; Spong, E. D.; Hammock, M. S.
1978-01-01
Peak distortion data taken from a subscale inlet model were studied to determine if the data can be used to predict peak distortion levels for a full scale flight test vehicle, and to provide a better understanding of the time variant total pressure distortion and the attendant effects of Reynolds number/scale and frequency content. The data base used to accomplish this goal covered a range from Mach 0.4 to 2.5 and an angle of attack range from -10 degrees to +12 degrees. Data are presented which show that: (1) increasing the Reynolds number increases total pressure recovery, decreases peak distortion, and decreases turbulence, (2) increasing the filter cutoff frequency increases both peak distortion and turbulence, and (3) the effect of engine presence on total pressure recovery, peak distortion, and turbulence is small but favorable.
Effect of resistance exercise training combined with relatively low vascular occlusion.
Sumide, Takahiro; Sakuraba, Keishoku; Sawaki, Keisuke; Ohmura, Hirotoshi; Tamura, Yoshifumi
2009-01-01
Previous studies have demonstrated that a low-intensity resistance exercise, combined with vascular occlusion, results in a marked increase in muscular size and strength. We investigated the optimal pressure for reduction of muscle blood flow with resistance exercise to increase the muscular strength and endurance. Twenty-one subjects were randomly divided into four groups by the different application of vascular occlusion pressure at the proximal of thigh: without any pressure (0-pressure group), with a pressure of 50mmHg (50-pressure group), with a pressure of 150mmHg (150-pressure group), and with a pressure of 250mmHg (250-pressure group). The isokinetic muscle strength at angular velocities of 60 and 180 degrees /s, total muscle work, and the cross-sectional knee extensor muscle area were assessed before and after exercise. Exercise was performed three times a week over an 8-week period at an intensity of approximately 20% of one-repetition maximum for straight leg raising and hip joint adduction and maximum force for abduction training. A significant increase in strength at 180 degrees /s was noted after exercise in all subjects who exercised under vascular occlusion. Total muscle work increased significantly in the 50- and 150-pressure groups (P<0.05, P<0.01, respectively). There was no significant increase in cross-sectional knee extensor muscle area in any groups. In conclusion, resistance exercise with relatively low vascular occlusion pressure is potentially useful to increase muscle strength and endurance without discomfort.
NASA Technical Reports Server (NTRS)
Allen, John L
1956-01-01
Unsteady shock-induced separation of the ramp boundary layer was reduced and stabilized more effectively by external perforations than by external or internal slots. At Mach 2.0 peak total-pressure recovery was increased from 0.802 to 0.89 and stable mass-flow range was increased 185 percent over that for the solid ramp. Peak pressure recovery occurred just before instability. The 7 and one-third-diameter duct ahead of the engine reduced large total-pressure distortions but was not as successful for small distortions as obtained with throat bleed. By removing boundary-layer air the bypass nearly recovered the total-pressure loss due to the long duct.
NASA Astrophysics Data System (ADS)
Gheshmi, M. S.; Fatahiyan, S. M.; Khanesary, N. T.; Sia, C. W.; Momeni, M. S.
2018-03-01
In this work, a comprehensive model for Nitrogen injection into an oil reservoir (southern Iranian oil fields) was developed and used to investigate the effects of rock porosity and permeability on the oil production rate and the reservoir pressure decline. The model was simulated and developed by using ECLIPSE300 software, which involved two scenarios as porosity change and permeability changes in the horizontal direction. We found that the maximum pressure loss occurs at a porosity value of 0.07, which later on, goes to pressure buildup due to reservoir saturation with the gas. Also we found that minimum pressure loss is encountered at porosity 0.46. Increases in both pressure and permeability in the horizontal direction result in corresponding increase in the production rate, and the pressure drop speeds up at the beginning of production as it increases. However, afterwards, this pressure drop results in an increase in pressure because of reservoir saturation. Besides, we determined the regression values, R, for the correlation between pressure and total production, as well as for the correlation between permeability and the total production, using neural network discipline.
Lipin, B.R.
1993-01-01
This paper explores the hypothesis that chromate seams in the Stillwater Complex formed in response to periodic increases in total pressure in the chamber. Total pressure increased because of the positive ??V of nucleation of CO2 bubbles in the melt and their subsequent rise through the magma chamber, during which the bubbles increased in volume by a factor of 4-6. By analogy with the pressure changes in the summit chambers of Kilauea and Krafla volcanoes, the maximum variation was 0.2-0.25 kbar, or 5-10% of the total pressure in the Stillwater chamber. An evaluation of the likelihood of fountaining and mixing of a new, primitive liquid that entered the chamber with the somewhat more evolved liquid already in the chamber is based upon calculations using observed and inferred velocities and flow rates of basaltic magmas moving through volcanic fissures. The calculations indicate that hot, dense magma would have oozed, rather than fountained into the chamber, and early mixing of the new and residual magmas that could have resulted in chromite crystallizing alone did not take place. -from Author
Larreguy, C; Carrera, A L; Bertiller, M B
2017-09-01
The objective of this study was to estimate the size and chemical quality of the total organic C stock and its partition between above-belowground plant parts and soil at sites with different plant cover induced by sheep grazing in the arid Patagonian Monte. This study was conducted at six representative sites with increasing signs of canopy disturbance attributed to grazing pressure. We used faeces density as a proxy of grazing pressure at each site. We assessed the total plant cover, shrub and perennial grass cover, total standing aboveground biomass (AGB), litter mass and belowground biomass (BGB) at each site. We further estimated the content of organic C, lignin and soluble phenols in plant compartments and the content of organic C, organic C in humic substances (recalcitrant C) and water soluble C (labile C) in soil at each site. Total plant cover was significantly related to grazing pressure. Standing AGB and litter mass decreased with increasing canopy disturbance while BGB did not vary across sites. Total organic C stock and the organic C stock in standing AGB increased with increasing total plant, shrub, and perennial grass cover. The organic C stock in litter mass increased with increasing total plant and shrub cover, while the organic C stock in BGB did not vary across sites. Lignin content in plant compartments increased with increasing total and shrub cover, while soluble phenols content did not change across sites. The organic C stock and the water soluble C content in soil were positively associated with perennial grass cover. Changes in total plant cover induced by grazing pressure negatively affected the size of the total organic C stock, having minor impact on the size of belowground than aboveground components. The reduction of perennial grass cover was reflected in decreasing chemical quality of the organic C stock in soil. Accordingly, plant managerial strategies should not only be focused on the amount of organic C sequestered but also on the chemical quality of organic C stocks since C chemistry could have an important impact on ecosystem functioning. Copyright © 2017 Elsevier Ltd. All rights reserved.
Renal and blood pressure effects from environmental cadmium exposure in Thai children
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swaddiwudhipong, Witaya, E-mail: swaddi@hotmail.com; Mahasakpan, Pranee; Jeekeeree, Wanpen
Very few studies have shown renal and blood pressure effects from environmental cadmium exposure in children. This population study examined associations between urinary cadmium excretion, a good biomarker of long-term cadmium exposure, and renal dysfunctions and blood pressure in environmentally exposed Thai children. Renal functions including urinary excretion of β{sub 2}-microglobulin, calcium (early renal effects), and total protein (late renal effect), and blood pressure were measured in 594 primary school children. Of the children studied, 19.0% had urinary cadmium ≥1 μg/g creatinine. The prevalence of urinary cadmium ≥1 μg/g creatinine was significantly higher in girls and in those consuming ricemore » grown in cadmium-contaminated areas. The geometric mean levels of urinary β{sub 2}-microglobulin, calcium, and total protein significantly increased with increasing tertiles of urinary cadmium. The analysis did not show increased blood pressure with increasing tertiles of urinary cadmium. After adjusting for age, sex, and blood lead levels, the analysis showed significant positive associations between urinary cadmium and urinary β{sub 2}-microglobulin and urinary calcium, but not urinary total protein nor blood pressure. Our findings provide evidence that environmental cadmium exposure can affect renal functions in children. A follow-up study is essential to assess the clinical significance and progress of renal effects in these children. - Highlights: • Few studies show renal effects from environmental cadmium exposure in children. • We report renal and blood pressure effects from cadmium exposure in Thai children. • Urinary β{sub 2}-microglobulin and calcium increased with increasing urinary cadmium. • The study found no association between urinary cadmium levels and blood pressure. • Environmental cadmium exposure can affect renal functions in children.« less
Ren, Shuai; Cai, Maolin; Shi, Yan; Xu, Weiqing; Zhang, Xiaohua Douglas
2018-03-01
Bronchial diameter is a key parameter that affects the respiratory treatment of mechanically ventilated patients. In this paper, to reveal the influence of bronchial diameter on the airflow dynamics of pressure-controlled mechanically ventilated patients, a new respiratory system model is presented that combines multigeneration airways with lungs. Furthermore, experiments and simulation studies to verify the model are performed. Finally, through the simulation study, it can be determined that in airway generations 2 to 7, when the diameter is reduced to half of the original value, the maximum air pressure (maximum air pressure in lungs) decreases by nearly 16%, the maximum flow decreases by nearly 30%, and the total airway pressure loss (sum of each generation pressure drop) is more than 5 times the original value. Moreover, in airway generations 8 to 16, with increasing diameter, the maximum air pressure, maximum flow, and total airway pressure loss remain almost constant. When the diameter is reduced to half of the original value, the maximum air pressure decreases by 3%, the maximum flow decreases by nearly 5%, and the total airway pressure loss increases by 200%. The study creates a foundation for improvement in respiratory disease diagnosis and treatment. Copyright © 2017 John Wiley & Sons, Ltd.
Evaluation of blood and serum markers in spinal cord injured patients with pressure sores.
Gurcay, Eda; Bal, Ajda; Gurcay, Ahmet G; Cakci, Aytul
2009-03-01
To evaluate blood and serum markers in traumatic spinal cord injured (SCI) patients, with and without pressure sores. This cross-sectional study was performed at the Ministry of Health Diskapi Yildirim Beyazit, and Numune Education and Research Hospitals, Ankara, Turkey, from 2006-2008. A total of 23 SCI patients with pressure sores (group I) and a control group of 25 SCI patients without pressure sores (group II) were evaluated. Characteristics of sores were examined with respect to duration, location, grade, tissue types, surface area, and exudate amount. Recorded laboratory parameters included erythrocyte sedimentation rates (ESR), C-reactive protein (CRP), hemoglobin (Hb), hematocrit (Htc), lymphocytes, white blood cells (WBC), red blood cells (RBC), serum iron, transferrin, total iron-binding capacity (TIBC), ferritin, total protein, albumin, vitamin B12, and zinc. The most common pressure sore location was the sacrum (38%). Compared to the control group, the patients with pressure sores showed anemia with reduced serum iron, transferrin, TIBC, and increased ferritin. They also had increased ESR, CRP, and WBC and reduced lymphocytes, total protein, albumin and zinc. Statistically significant correlations were found between CRP, Hb, Htc, lymphocytes, RBC, WBC, and serum protein levels, and grade of pressure sores. Clinicians should regularly screen patients with respect to blood and serum markers, in order to determine any risks for pressure sores, and they should perform immediate preventive measures based on the patient's condition.
Ogilvie, R I; Zborowska-Sluis, D
1991-10-01
To determine whether changes in vascular capacitance induced by nitroglycerin (NTG) and nitroprusside were due to changes in compliance or unstressed vascular volume, doses producing similar reductions in arterial pressure (Psa) were studied on separate days in six dogs anesthetized and ventilated with pentobarbital after splenectomy during ganglion blockade with hexamethonium. Mean circulatory filling pressure (Pmcf) was determined during transient circulatory arrest induced by acetylcholine at baseline blood volumes and after increases of 5 and 10 ml/kg. Central blood volumes (CBVs, pulmonary artery to aortic root) were determined from transit times, and separately measured cardiac output (CO) was estimated by thermodilution (right atrium to pulmonary artery). NTG and nitroprusside produced similar reductions in Psa and Pmcf without significantly altering right atrial pressure (Pra), pressure gradient for venous return, or CO. Total vascular compliance was not altered, but total vascular capacitance was increased on an average of 4.0 +/- 1.4 ml/kg after NTG and 3.0 +/- 1.3 ml/kg after nitroprusside by increases in unstressed volume. Both drugs caused a variable reduction in CBV, averaging 2 ml/kg. Thus, both drugs produced a large increase in peripheral venous capacitance by increasing unstressed vascular volume without altering total vascular compliance.
Oswald, Florian; Stoll, I. Katharina; Zwick, Michaela; Herbig, Sophia; Sauer, Jörg; Boukis, Nikolaos; Neumann, Anke
2018-01-01
Low productivities of bioprocesses using gaseous carbon and energy sources are usually caused by the low solubility of those gases (e.g., H2 and CO). It has been suggested that increasing the partial pressure of those gases will result in higher dissolved concentrations and should, therefore, be helpful to overcome this obstacle. Investigations of the late 1980s with mixtures of hydrogen and carbon monoxide showed inhibitory effects of carbon monoxide partial pressures above 0.8 bar. Avoiding any effects of carbon monoxide, we investigate growth and product formation of Clostridium ljungdahlii at absolute process pressures of 1, 4, and 7 bar in batch stirred tank reactor cultivations with carbon dioxide and hydrogen as sole gaseous carbon and energy source. With increasing process pressure, the product spectrum shifts from mainly acetic acid and ethanol to almost only formic acid at a total system pressure of 7 bar. On the other hand, no significant changes in overall product yield can be observed. By keeping the amount of substance flow rate constant instead of the volumetric gas feed rate when increasing the process pressure, we increased the overall product yield of 7.5 times of what has been previously reported in the literature. After 90 h of cultivation at a total pressure of 7 bar a total of 4 g L−1 of products is produced consisting of 82.7 % formic acid, 15.6 % acetic acid, and 1.7 % ethanol. PMID:29484294
Wong, Brett J.
2011-01-01
Octreotide is a somatostatin analog that constricts the splanchnic circulation, thereby improving orthostatic tolerance. We tested the hypotheses that octreotide improves orthostatic tolerance by 1)increasing cardiac filling (right atrial) pressure via reductions in vascular capacity; 2) by causing an upward (i.e., cranial) shift of the hydrostatic indifferent point; and 3) by increasing arterial pressure via a reduction in total vascular conductance. Studies were carried out in acepromazine-sedated, hexamethonium-treated atrioventricular-blocked conscious dogs lightly restrained in lateral recumbency. Beat-by-beat cardiac output was held constant via computer-controlled ventricular pacing at rest and during 30 s of 30° head-up tilt. Octreotide (1.5 μg/kg iv) raised right atrial pressure by 0.5 mmHg and raised mean arterial pressure by 11 mmHg by reducing total vascular conductance (all P < 0.05). Right atrial pressure fell by a similar amount in response to tilting before and after octreotide, thus there was no difference in location of the hydrostatic indifferent point. These data indicate that octreotide improves orthostatic tolerance by decreasing total vascular conductance and by increasing cardiac filling pressure via a reduction in unstressed vascular volume and not by eliciting a cranial shift of the location of the hydrostatic indifferent point. PMID:21512154
Terminal energy distribution of blast waves from bursting spheres
NASA Technical Reports Server (NTRS)
Adamczyk, A. A.; Strehlow, R. A.
1977-01-01
The calculation results for the total energy delivered to the surroundings by the burst of an idealized massless sphere containing an ideal gas are presented. The logic development of various formulas for sphere energy is also presented. For all types of sphere bursts the fraction of the total initial energy available in the sphere that is delivered to the surroundings is shown to lie between that delivered for the constant pressure addition of energy to a source region and that delivered by isentropic expansion of the sphere. The relative value of E sub/Q increases at fixed sphere pressure/surrounding pressure as sphere temperature increases because the velocity of sound increases.
Tang, Simon Fuk-Tan; Chen, Carl P C; Lin, Shih-Cherng; Wu, Chih-Kuan; Chen, Chih-Kuang; Cheng, Shun-Ping
2015-02-01
The purpose of this study was to observe whether our custom made shoes and total contact insoles can effectively increase the plantar contact areas and reduce peak pressures in patients with leprosy. In the rehabilitation laboratory of a tertiary medical center. Six male and two female leprosy patients were recruited in this study. In this study, parameters related to foot pressures were compared between these patients wearing commercial available soft-lining kung-fu shoes and our custom made shoes with total contact insoles. The custom made shoes were made with larger toe box and were able to accommodate both the foot and the insoles. Custom made total contact insoles were made with the subtalar joints under neutral and non-weight-bearing positions. The insole force measurement system of Novel Pedar-X (Novel, Munich, Germany) was used to measure the plantar forces. The parameters of contact area (cm(2)), peak plantar pressures (kPa), contact time (s), and pressure time integral (kPa s) were measured. There were significant contact area increases in the right and left foot heel areas, left medial arch, and second to fifth toes after wearing the custom made shoes and insoles. There were significant decreases in peak plantar pressures in bilateral heels, left lateral midfoot, bilateral second to fourth metatarsal areas, and left fifth metatarsal head after wearing the custom made shoes and insoles (p<0.05). Plantar ulceration is a common serious disability in leprosy patients. As a result, footwear and measures able to reduce plantar pressures may be beneficial in preventing plantar ulcers from occurring in these patients. Our custom made shoes and total contact insoles were proven to be effective in increasing contact areas and decreasing peak pressures in plantar surfaces, and may therefore be a feasible treatment option in preventing leprosy patients from developing plantar ulcers. © 2015 Elsevier B.V. All rights reserved.
Zhi, Zhongwei; Cepurna, William; Johnson, Elaine; Jayaram, Hari; Morrison, John; Wang, Ruikang K
2015-09-01
To determine if retinal capillary filling is preserved in the face of acutely elevated intraocular pressure (IOP) in anesthetized rats, despite a reduction in total retinal blood flow (RBF), using optical microangiography/optical coherence tomography (OMAG/OCT). OMAG provided the capability of depth-resolved imaging of the retinal microvasculature down to the capillary level. Doppler OCT was applied to measure the total RBF using an enface integration approach. The microvascular pattern, capillary density, and total RBF were monitored in vivo as the IOP was increased from 10 to 100mmHg in 10mmHg intervals and returned back to 10mmHg. In animals with mean arterial pressure (MAP) of 102±4mmHg (n=10), when IOP was increased from 0 to 100mmHg, the capillary density remained at or above 80% of baseline for the IOP up to 60mmHg [or ocular perfusion pressure (OPP) at 40mmHg]. This was then decreased, achieving 60% of baseline at IOP 70mmHg and OPP of 30mmHg. Total RBF was unaffected by moderate increases in IOP up to 30mmHg, beyond which total RBF decreased linearly, reaching 50% of baseline at IOP 60mmHg and OPP 40mmHg. Both capillary density and total RBF were totally extinguished at 100mmHg, but fully recovered when IOP returned to baseline. By comparison, a separate group of animals with lower MAP (mean=75±6mmHg, n=7) demonstrated comparable decreases in both capillary filling and total RBF at IOPs that were 20mmHg lower than in the initial group. Both were totally extinguished at 80mmHg, but fully recovered when IOP returned to baseline. Relationships of both parameters to OPP were unchanged. Retinal capillary filling and total RBF responses to IOP elevation can be monitored non-invasively by OMAG/OCT and both are influenced by OPP. Retinal capillary filling was relatively preserved down to a perfusion pressure of 40mmHg, despite a linear reduction in total RBF. Copyright © 2015 Elsevier Inc. All rights reserved.
Pressure sores and blood and serum dysmetabolism in spinal cord injury patients.
Scivoletto, G; Fuoco, U; Morganti, B; Cosentino, E; Molinari, M
2004-08-01
Spinal cord injury (SCI) patients with pressure sores were studied before and after surgical intervention for ulcer healing and compared with matched SCI patients without sores and with patients with pressure sores and other diseases. To analyse the relationship between pressure sores and anaemia and serum protein alteration in SCI patients. To study the pathogenesis of these alterations and suggest appropriate therapy. Spinal cord unit in Rome, Italy. A total of 13 SCI patients with pressure sores, 13 comparable patients without pressure sores and four patients with other diseases and pressure sores. Haematochemical parameters. Patients with pressure sore showed significant decreased red cells, decreased haemoglobin and haematocrit, increased white cells and ferritin and decreased transferrin and transferrin saturation; total hypoproteinemia and hypoalbuminemia with increased Alfa-1 and gamma globulins increased erythrocyte sedimentation rate and C-reactive protein were also present. The alterations returned to normal after surgical intervention for pressure sore healing. Patients with pressure sores suffer from anaemia and serum protein alteration that fells within the range of metabolic alteration of chronic disorders and neoplastic diseases. The alterations depend on a decreased utilisation of iron stores in the reticuloendothelial system and on inhibition of the hepatic synthesis of albumin. With regard to treatment, iron treatment should be avoided because of the risk of haemochromatosis.
Ferreira, Lucas Lima; Valenti, Vitor Engrácia; Vanderlei, Luiz Carlos Marques
2013-01-01
Objective To analyze the outcomes of increased or decreased intracranial pressure and/or the decrease in cerebral perfusion pressure resulting from respiratory physiotherapy on critically ill patients admitted to the intensive care unit. Methods Through a systematic review of the literature, clinical trials published between 2002 and 2012 were selected. The search involved the LILACS, SciELO, MedLine and PEDro databases using the keywords "physical therapy", "physiotherapy", "respiratory therapy" and "randomized controlled trials" combined with the keyword "intracranial pressure". Results In total, five studies, including a total of 164 patients between 25 and 65 years of age, reporting that respiratory physiotherapy maneuvers significantly increased intracranial pressure without changing the cerebral perfusion pressure were included. The articles addressed several techniques including vibration, vibrocompression, tapping, postural drainage, and the endotracheal aspiration maneuver. All patients required invasive mechanical ventilation. Conclusion Respiratory physiotherapy leads to increased intracranial pressure. Studies suggest that there are no short-term hemodynamic or respiratory repercussions or changes in the cerebral perfusion pressure. However, none of the studies evaluated the clinical outcomes or ensured the safety of the maneuvers. PMID:24553515
Energy evolution mechanism in process of Sandstone failure and energy strength criterion
NASA Astrophysics Data System (ADS)
Wang, Yunfei; Cui, Fang
2018-07-01
To reveal the inherent relation between energy change and confining pressure during the process of sandstone damage, and its characteristics of energy storage and energy dissipation in different deformation stage. Obtaining the mechanical parameters by testing the Sandstone of two1 coal seam roof under uniaxial compression in Zhaogu coalmine, using Particle Flow Code (PFC) and fish program to get the meso-mechanical parameters, studying Sandstone energy evolution mechanism under different confining pressures, and deducing energy strength criterion based on energy principle of rock failure, some main researching results are reached as follows: with the increasing of confining pressure, the Sandstone yield stage and ductility increases, but brittleness decreases; Under higher confining pressure, the elastic strain energy of Sandstone before peak approximately keeps constant in a certain strain range, and rock absorbs all the energy which converts into surface energy required for internal damage development; Under lower confining pressure, Sandstone no longer absorbs energy with increasing strain after peak under lower confining pressure, while it sequentially absorbs energy under higher confining pressure; Under lower confining pressure, the energy Sandstone before peak absorbed mainly converts into elastic strain energy, while under higher confining pressure, dissipation energy significantly increases before peak, which indicates that the degree rock strength loss is higher under higher confining pressure; with the increasing of confining pressure, the limit of elastic strain energy increases and there exists a favourable linear variation relationship; At the peak point, the ratio of elastic strain energy to total energy of Sandstone nonlinearly decreases, while the ratio of dissipation energy to total energy nonlinearly increases with the increasing of confining pressure; According to energy evolution mechanism of rock failure, an energy strength criterion is derived. The criterion equation includes lithology constants and three principal stresses, and its physical meaning is clear. This criterion has an evident advantage than Hoek-Brown and Drucker-Prager criterion in calculation accuracy and can commendably describe rock failure characteristics.
The effects of running cadence manipulation on plantar loading in healthy runners.
Wellenkotter, J; Kernozek, T W; Meardon, S; Suchomel, T
2014-08-01
Our purpose was to evaluate effects of cadence manipulation on plantar loading during running. Participants (n=38) ran on a treadmill at their preferred speed in 3 conditions: preferred, 5% increased, and 5% decreased while measured using in-shoe sensors. Data (contact time [CT], peak force [PF], force time integral [FTI], pressure time integral [PTI] and peak pressure [PP]) were recorded for 30 right footfalls. Multivariate analysis was performed to detect differences in loading between cadences in the total foot and 4 plantar regions. Differences in plantar loading occurred between cadence conditions. Total foot CT and PF were lower with a faster cadence, but no total foot PP differences were observed. Faster cadence reduced CT, pressure and force variables in both the heel and metatarsal regions. Increasing cadence did not elevate metatarsal loads; rather, total foot and all regions were reduced when healthy runners increased their cadence. If a 5% increase in cadence from preferred were maintained over each mile run the impulse at the heel would be reduced by an estimated 565 body weights*s (BW*s) and the metatarsals 140-170 BW*s per mile run despite the increased steps taken. Increasing cadence may benefit overuse injuries associated with elevated plantar loading. © Georg Thieme Verlag KG Stuttgart · New York.
González-Cebrino, Francisco; Durán, Rocío; Delgado-Adámez, Jonathan; Contador, Rebeca; Bernabé, Rosario Ramírez
2016-04-01
Physicochemical parameters, bioactive compounds' content (carotenoids and total phenols), total antioxidant activity, and enzymatic activity of polyphenol oxidase (PPO) were evaluated after high pressure processing (HPP) on a pumpkin purée (cv. 'Butternut'). Three pressure levels (400, 500, and 600 MPa) were combined with three holding times (200, 400, and 600 s). The applied treatments reduced the levels of total aerobic mesophilic (TAM), total psychrophilic and psychrotrophic bacteria (TPP), and molds and yeasts (M&Y). All applied treatments did not affect enzymatic activity of PPO. Pressure level increased CIE L* values, which could enhance the lightness perception of high pressure (HP)-treated purées. No differences were found between the untreated and HP-treated purées regarding total phenols and carotenoids content (lutein, α-carotene, and β-carotene) and total antioxidant activity. HPP did not affect most quality parameters and maintained the levels of bioactive compounds. However, it did not achieve the complete inhibition of PPO, which could reduce the shelf-life of the pumpkin purée. © The Author(s) 2015.
Almodhen, Fayez; Capolicchio, Jean Paul; Jednak, Roman; El Sherbiny, Mohamed
2007-10-01
We examined the urodynamic and upper urinary tract changes in children with myelomeningocele treated conservatively through puberty at our institution between 1980 and 2006. A total of 40 patients were exclusively treated conservatively with or without anticholinergics and/or clean intermittent catheterization through puberty at our institution. The records of 37 patients (17 males and 20 females) were available for review and constituted the subject matter for our study. The neurological lesion was sacral in 4 patients, lumbosacral in 5, thoracic in 12 and lumbar in 16. Clinical evaluations, radiological imaging studies of the upper urinary tract and urodynamic studies were repeated every 6 to 12 months. Data were collected and comparisons were made with respect to prepubertal (age 10 years) and postpubertal (15) continence status, urodynamic parameters and upper urinary tract changes. Children spontaneously achieving urinary continence postpubertally were examined in a similar fashion as a separate subgroup. Continence was defined as a dry interval of 4 hours or more. Of the 26 patients with urinary incontinence before puberty 12 (2 males and 10 females, 45%, p <0.003) achieved continence following puberty. Hydronephrosis remained stable in 4 patients, improved in 3 and was new onset in 3 (p >0.05). Vesicoureteral reflux persisted in 1 patient, resolved in 4 and was new onset in 1 (p >0.05). Total cystometric bladder capacity, maximum detrusor pressure and detrusor leak point pressure all increased significantly after puberty, from 277 +/- 82 to 487 +/- 140 ml, 45 +/- 17 to 54 +/- 20 cm H(2)O and 49 +/- 16 to 59 +/- 21 cm H2O, respectively. In patients achieving urinary continence following puberty total cystometric bladder capacity increased significantly from 284 +/- 58 to 473 +/- 93 ml (p <0.005). Maximum detrusor pressure and detrusor leak point pressure showed insignificant changes after puberty, increasing from 45 +/- 11 to 47 +/- 16 cm H2O and from 46 +/- 11 to 55 +/- 21 cm H2O, respectively. This study demonstrates that total cystometric bladder capacity, maximum detrusor pressure and detrusor leak point pressure increase significantly in patients with myelomeningocele following puberty. The increase in bladder capacity could be attributed to increasing bladder outlet resistance resulting from prostate gland enlargement in males and estrogenization in females. A significant number of patients spontaneously achieve continence at puberty, and continence becomes more likely when increased total cystometric bladder capacity is not associated with an increase in maximum detrusor pressure. Finally, no significant postpubertal upper urinary tract deterioration was observed in our series.
Extraction of ewe's milk cream with supercritical carbon dioxide.
González Hierro, M T; Ruiz-Sala, P; Alonso, L; Santa-María, G
1995-04-01
The extraction of ewe's milk cream by supercritical carbon dioxide in the pressure range 9-30 MPa (90-300 bar) and at temperatures of 40 degrees C and 50 degrees C was studied. The solubility of total fat increased with pressure at both temperatures until a plateau was reached. The extraction of cholesterol also increased with pressure until a plateau was reached and it was higher at 50 degrees C than at 40 degrees C when the pressure was > or = 15 MPa (150 bar). The triglyceride composition of each extract, determined by GC, showed that extracts obtained at lower pressures were enriched in short-chain triglycerides and their concentration decreased as the pressure increased. In the other hand, long-chain triglycerides were enriched in the extracts obtained at higher pressures and their concentration rose with increasing pressure.
Zhang, Jing; Mifflin, Steven W
2000-01-01
Using electrophysiological techniques, the discharge of neurones in the nucleus of the solitary tract (NTS) receiving aortic depressor nerve (ADN) inputs was examined during blood pressure changes induced by I.V. phenylephrine or nitroprusside in anaesthetized, paralysed and artificially ventilated rats. Various changes in discharge rate were observed during phenylephrine-induced blood pressure elevations: an increase (n = 38), a decrease (n = 5), an increase followed by a decrease (n = 4) and no response (n = 11). In cells receiving a monosynaptic ADN input (MSNs), the peak discharge frequency response was correlated to the rate of increase in mean arterial pressure (P < 0.01) but was not correlated to the absolute increase in blood pressure. The peak discharge frequency response of cells receiving a polysynaptic ADN input (PSNs) was correlated to neither the absolute increase in blood pressure nor the rate of increase in mean arterial pressure. Diverse changes in discharge rate were observed during nitroprusside-induced reductions in blood pressure: an increase (n = 3), a decrease (n = 10), an increase followed by a decrease (n = 3) and no response (n = 6). Reductions in pressure of 64 ± 2 mmHg produced weak reductions in spontaneous discharge of 1.3 ± 0.9 Hz and only totally abolished spontaneous discharge in one neurone. These response patterns of NTS neurones during changes in arterial pressure suggest that baroreceptor inputs are integrated differently in MSNs compared to PSNs. The sensitivity of MSNs to the rate of change of pressure provides a mechanism for the rapid regulation of cardiovascular function. The lack of sensitivity to the mean level of a pressure increase in both MSNs and PSNs suggests that steady-state changes in pressure are encoded by the number of active neurones and not graded changes in the discharge of individual neurones. Both MSNs and PSNs receive tonic excitatory inputs from the arterial baroreceptors; however, these tonic inputs appear to be insufficient to totally account for their spontaneous discharge. PMID:11101652
NASA Technical Reports Server (NTRS)
Debogdan, C. E.; Moss, J. E., Jr.; Braithwaite, W. M.
1977-01-01
The measured distribution of compressor interstage pressures and temperatures resulting from a 180 deg inlet-total-pressure distortion for a J85-13 turbojet engine is reported. Extensive inner stage instrumentation combined with stepwise rotation of the inlet distortion gave data of high circumferential resolution. The steady-state pressures and temperatures along with the amplitude, extent, and location of the distorted areas are given. Data for 80, 90, and 100 percent of rotor design speed are compared with clean (undistorted) inlet flow conditions to show pressure and temperature behavior within the compressor. Both overall and stagewise compressor performances vary only slightly when clean and distorted inlet conditions are compared. Total and static pressure distortions increase in amplitude in the first few stages of the compressor and then attenuate fairly uniformly to zero at the discharge. Total-temperature distortion induced by the pressure distortion reached a maximum amplitude by the first two stages and decayed only a little through the rest of the compressor. Distortion amplitude tended to peak in line with the screen edges, and, except for total and static pressure in the tip zone, there was little swirl in the axial direction.
Cheng, Zheng-Jun; Wang, Yun-Bing; Chen, Long; Gong, Jian-Ping; Zhang, Wei
2018-04-18
The aim of this meta-analysis is to compare the differences in postoperative markers of the hepatic function under different intra-abdominal pressures in laparoscopic cholecystectomy (LC). Several databases were searched for control studies, and then the weighted data were pooled with random-effect models. A total of 11 studies involving 865 patients were included. The meta-analysis reveals that the level of the aspartate aminotransferase and alanine transaminase of the low-pressure group has a lower postoperative increase than the moderate-pressure group (P<0.001). The level of the aspartate aminotransferase and alanine transaminase of the moderate-pressure group has a lower postoperative increase than the high-pressure group (P<0.001). Totally, the effect of lower pressure LC on postoperative hepatic functions is less significant than that of the higher one. Potential subgroup analysis does not modify these results. The recommended pressure in LC is suggested to be lower so as to result in a better surgical safety, especially for special populations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Bin, E-mail: hnsqxubin@163.com; Gao, Changzheng; Zhang, Jing
2016-05-15
A lot of physical properties of Th{sub 2}S{sub 3}-type Ti{sub 2}O{sub 3} have investigated experimentally, hence, we calculated electronic structure and thermoelectric transport properties by the first-principles calculation under pressure. The increase of the band gaps is very fast from 30 GPa to 35 GPa, which is mainly because of the rapid change of the lattice constants. The total density of states becomes smaller with increasing pressure, which shows that Seebeck coefficient gradually decreases. Two main peaks of Seebeck coefficients always decrease and shift to the high doping area with increasing temperature under pressure. The electrical conductivities always decrease withmore » increasing temperature under pressure. The electrical conductivity can be improved by increasing pressure. Electronic thermal conductivity increases with increasing pressure. It is noted that the thermoelectric properties is reduced with increasing temperature.« less
Effect of variable body mass on plantar foot pressure and off-loading device efficacy.
Pirozzi, Kelly; McGuire, James; Meyr, Andrew J
2014-01-01
An increasing body of evidence has implicated obesity as having a negative effect on the development, treatment, and outcome of lower extremity pathologic entities, including diabetic foot disease. The objective of the present study was to increase the body of knowledge with respect to the effects of obesity on foot function. Specifically, we attempted to (1) describe the relationship between an increasing body mass index (BMI) on plantar foot pressures during gait, and (2) evaluate the efficacy of commonly prescribed off-loading devices with an increasing BMI. A repeated measures design was used to compare the peak plantar foot pressures under multiple test conditions, with the volunteers acting as their own controls. The primary outcome measure was the mean peak plantar pressure in the heel, midfoot, forefoot, and first metatarsal, and the 2 variables were modification of patient weight (from "normal" BMI to "overweight," "obese," and "morbidly obese") and footwear (from an athletic sneaker to a surgical shoe, controlled ankle motion walker, and total contact cast). Statistically significant increases in the peak plantar pressures were observed with increasing volunteer BMI weight class, regardless of the off-loading device used. The present investigation has provided unique and specific data with respect to the changes that occur in the peak plantar pressures with variable BMIs across different anatomic levels and with commonly used off-loading devices. From our results, we have concluded that although the plantar pressures increase with increasing weight, it appears that at least some reduction in pressure can be achieved with an off-loading device, most effectively with the total contact cast, regardless of the patient's BMI. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Dencker, Magnus; Arvidsson, Daniel; Karlsson, Magnus K; Wollmer, Per; Andersen, Lars B; Thorsson, Ola
2018-03-01
Galectin-3 has recently been proposed as a novel biomarker for cardiovascular disease in adults. The purpose of this investigation was to assess relationships between galectin-3 levels and total body fat, abdominal fat, body fat distribution, aerobic fitness, blood pressure, left ventricular mass, left atrial size, and increase in body fat over a 2-year period in a population-based sample of children. Our study included 170 children aged 8-11 years. Total fat mass and abdominal fat were measured by dual-energy x-ray absorptiometry (DXA). Body fat distribution was expressed as abdominal fat/total fat mass. Maximal oxygen uptake was assessed by indirect calorimetry during a maximal exercise test and scaled to body mass. Systolic and diastolic blood pressure and pulse pressure were measured. Left atrial size, left ventricular mass, and relative wall thickness were measured by echocardiography. Frozen serum samples were analyzed for galectin-3 by the Proximity Extension Assay technique. A follow-up DXA scan was performed in 152 children 2 years after the baseline exam. Partial correlations, with adjustment for sex and age, between galectin-3 versus body fat measurements indicated weak to moderate relationships. Moreover, left atrial size, left ventricular mass, and relative wall thickness and pulse pressure were also correlated with galectin-3. Neither systolic blood pressure nor maximal oxygen uptake was correlated with galectin-3. There was also a correlation between galectin-3 and increase in total body fat over 2 years, while no such correlations were found for the other fat measurements. More body fat and abdominal fat, more abdominal body fat distribution, more left ventricular mass, and increased left atrial size were all associated with higher levels of galectin-3. Increase in total body fat over 2 years was also associated with higher levels of galectin-3. What is Known: • Galectin-3 has been linked to obesity and been proposed to be a novel biomarker for cardiovascular disease in adults. • Information on this subject in children is very scarce. What is New: • The present study demonstrates a relationship between galectin-3 levels and total body fat, abdominal fat, body fat distribution, cardiac size and geometry, and increase in total body fat over 2 years in young children.
Kim, Hyun-Min Mike; Chacon, Alexander C; Andrews, Seth H; Roush, Evan P; Cho, Edward; Conaway, William K; Kunselman, Allen R; Lewis, Gregory S
2016-04-01
Restoration of joint stability during total shoulder arthroplasty can be challenging in the face of severe glenoid retroversion. A novel technique of humeral head component anterior-offsetting has been proposed to address posterior instability. We evaluated the biomechanical benefits of this technique in cadaveric specimens. Total shoulder arthroplasty was performed in 14 cadaveric shoulders from 7 donors. Complementary shoulders were assigned to either 10° or 20° glenoid retroversion, with retroversion created by eccentric reaming. Two humeral head component offset positions were tested in each specimen: The anatomic (posterior) and anterior (reverse). With loads applied to the rotator cuff and deltoid, joint contact pressures and the force and energy required for posterior humeral head translation were measured. The force and energy required to displace the humeral head posteriorly increased significantly with the anterior offset position compared to the anatomic offset position. The joint contact pressures were significantly shifted anteriorly, and the joint contact area significantly increased with the anterior offset position. Anterior offsetting of the humeral head component increased the resistance to posterior humeral head translation, shifted joint contact pressures anteriorly, and increased joint contact area, thus, potentially increasing the joint stability in total shoulder arthroplasty with simulated glenoid retroversion. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Zhou, Aimei; Lin, Liying; Liang, Yan; Benjakul, Soottawat; Shi, Xiaoling; Liu, Xin
2014-08-01
Changes of physicochemical properties in natural actomyosin (NAM) from threadfin bream (Nemipterus spp.) induced by high hydrostatic pressure (200, 400, 600MPa for 10, 30, 50min) were studied. The increase in turbidity of NAM was coincidental with the decrease in protein solubility with increasing pressure and time, suggesting the formation of protein aggregates. SDS-PAGE showed that polymerisation and degradation of myosin heavy chain were induced by high pressure. Ca(2+)-ATPase activity of NAM treated by high pressure was lost, suggesting the denaturation of myosin and the dissociation of actomyosin complex. Surface hydrophobicity of NAM increased when the pressure and pressurization time increased, indicating that the exposed hydrophobic residues increased upon application of high pressure. Decrease in total sulfhydryl content and increase in surface-reactive sulfhydryl content of NAM samples were observed with the extension of pressurizing time, indicating the formation of disulphide bonds through oxidation of SH groups or disulphide interchanges. The above changes of physicochemical properties suggested conformational changes of NAM from muscle of threadfin bream induced by high hydrostatic pressure. Copyright © 2014 Elsevier Ltd. All rights reserved.
Tanner, Dwight Q.; Harrison, Howard E.; McKenzie, Stuart W.
1996-01-01
Increased levels of total dissolved gas pressure can cause gas-bubble trauma in fish downstream from dams on the Columbia River. In cooperation with the U.S. Army Corps of Engineers, the U.S. Geological Survey collected data on total dissolved gas pressure, barometric pressure, water temperature, and dissolved oxygen pressure at 11 stations on the lower Columbia River from the John Day forebay (river mile 215.6) to Wauna Mill (river mile 41.9) from March to September 1996. Methods of data collection, review, and processing are described in this report. Summaries of daily minimum, maximum, and mean hourly values are presented for total dissolved gas pressure, barometric pressure, and water temperature. Hourly values for these parameters are presented graphically. Dissolved oxygen data are not presented in this report because the quality-control data show that the data have poor precision and high bias. Suggested changes to monitoring procedures for future studies include (1) improved calibration procedures for total dissolved gas and dissolved oxygen to better define accuracy at elevated levels of supersaturation and (2) equipping dissolved oxygen sensors with stirrers because river velocities at the shoreline monitoring stations probably cannot maintain an adequate flow of water across the membrane surface of the dissolved oxygen sensor.
Biggi, N; Consonni, D; Fragasso, G; Lattuada, G; Perseghin, G L; Verga, R; Costa, G
2007-01-01
Aim of the study is to explore in shiftworkers: a) blood pressure and hormonal variations; b) dyslipidemia and blood glucose levels; c) insulin resistence syndrome. We have assessed 48 male workers employes in Amsa SpA, a large municipal enterprise in charge of street cleaning and domestic waste collection, in permanent day and night work as hand sweepers, motor sweepers and delivery tricar drivers. 24 of those workers (daily and nightly) were normotensive and 24 were hypertensive. Our medical checks were: physical examination: BMI; laboratory findings (blood): glucose, total cholesterol, triglycerides, endothelin, insulin, FFA, HOMA S, HOMA B, HOMA R; assay of salivary cortisol and urinary cortisol in 24 h; 24 h pressure monitoring. Nightly hypertensive: increased consumption in wine and coffee, weight and BMI, total cholesterol and FFA and endothelin. Nightly normotensive: increased consumption in cigarettes and salivary cortisol. Daily hypertensive: increased total cholesterol; 24 h pressure monitoring showed more pronounced variations of pressure in night workers both normotensive and hypertensive in working time. Night shiftwork looks like more stressfull than day shiftwork. Insuline resistance isn't noticed in all four groups.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cook, J.M.; Sheppard, M.C.; Houwen, O.H.
Previous work on shale mechanical properties has focused on the slow deformation rates appropriate to wellbore deformation. Deformation of shale under a drill bit occurs at a very high rate, and the failure properties of the rock under these conditions are crucial in determining bit performance and in extracting lithology and pore-pressure information from drilling parameters. Triaxial tests were performed on two nonswelling shales under a wide range of strain rates and confining and pore pressures. At low strain rates, when fluid is relatively free to move within the shale, shale deformation and failure are governed by effective stress ormore » pressure (i.e., total confining pressure minus pore pressure), as is the case for ordinary rock. If the pore pressure in the shale is high, increasing the strain rate beyond about 0.1%/sec causes large increases in the strength and ductility of the shale. Total pressure begins to influence the strength. At high stain rates, the influence of effective pressure decreases, except when it is very low (i.e., when pore pressure is very high); ductility then rises rapidly. This behavior is opposite that expected in ordinary rocks. This paper briefly discusses the reasons for these phenomena and their impact on wellbore and drilling problems.« less
Contralateral limb during total contact casting. A dynamic pressure and thermometric analysis.
Armstrong, D G; Liswood, P J; Todd, W F
1995-12-01
The authors draw attention to the importance of evaluation of the contralateral limb when treating unilateral sequelae secondary to distal symmetrical polyneuropathy. Plantar pressure measurements of the contralateral limb during total contact casting are reviewed. The results of thermometric evaluation before and after initiation of repetitive stress were reviewed. The results suggest that the patient walking in a total contact cast may experience a reduced focal pressure on the contralateral limb when compared with uncasted walking and three-point walking with crutches. Dermal thermometry may be a highly sensitive tool in evaluating even mild increases in repetitive stress. To explain this decrease in contralateral stress, the authors examine the features inherent to the total contact cast and propose the concept of proprioceptive stability.
NASA Technical Reports Server (NTRS)
Lagen, Nicholas; Seiner, John M.
1990-01-01
Water cooled supersonic probes are developed to investigate total pressure, static pressure, and total temperature in high-temperature jet plumes and thereby determine the mean flow properties. Two probe concepts, designed for operation at up to 1366 K in a Mach 2 flow, are tested on a water cooled nozzle. The two probe designs - the unsymmetric four-tube cooling configuration and the symmetric annular cooling design - take measurements at 755, 1089, and 1366 K of the three parameters. The cooled total and static pressure readings are found to agree with previous test results with uncooled configurations. The total-temperature probe, however, is affected by the introduction of water coolant, and effect which is explained by the increased heat transfer across the thermocouple-bead surface. Further investigation of the effect of coolant on the temperature probe is proposed to mitigate the effect and calculate more accurate temperatures in jet plumes.
Sunwoo, Hoon H; Kim, Chong-Tai; Kim, Do-Yeon; Maeng, Jin-Soo; Cho, Chang-Won; Lee, Soo-Jeong
2013-07-01
A combination of high hydrostatic pressure (HHP) and enzymatic hydrolysis (HHP-EH) was applied for the extraction of ginsenosides from fresh ginseng roots (Panax ginseng C.A. Myer). The highest yield of ginsenosides was obtained by using a mixture of three enzymes (Celluclast + Termamyl + Viscozyme) along with HHP (100 MPa, at 50 °C for 12 h) in comparison to control samples (no enzymes, atmosphere pressure, P < 0.05). Total ginsenosides increased by 184% while Rg1 + Rb1 increased by 273%. Application of these conditions significantly increased total ginsenosides by 49% and Rg1 + Rb1 by 103% compared to HHP treatment alone (P < 0.05). The effect of HHP on increased yield of ginsenosides is likely due in part, to acceleration of enzyme activity. Thus HHP-EH significantly improves the extraction of ginsenosides from fresh ginseng roots.
Variation with Mach Number of Static and Total Pressures Through Various Screens
NASA Technical Reports Server (NTRS)
Adler, Alfred A
1946-01-01
Tests were conducted in the Langley 24-inch highspeed tunnel to ascertain the static-pressure and total-pressure losses through screens ranging in mesh from 3 to 12 wires per inch and in wire diameter from 0.023 to 0.041 inch. Data were obtained from a Mach number of approximately 0.20 up to the maximum (choking) Mach number obtainable for each screen. The results of this investigation indicate that the pressure losses increase with increasing Mach number until the choking Mach number, which can be computed, is reached. Since choking imposes a restriction on the mass rate of flow and maximum losses are incurred at this condition, great care must be taken in selecting the screen mesh and wire dimmeter for an installation so that the choking Mach number is
Exhaled air dispersion during noninvasive ventilation via helmets and a total facemask.
Hui, David S; Chow, Benny K; Lo, Thomas; Ng, Susanna S; Ko, Fanny W; Gin, Tony; Chan, Matthew T V
2015-05-01
Noninvasive ventilation (NIV) via helmet or total facemask is an option for managing patients with respiratory infections in respiratory failure. However, the risk of nosocomial infection is unknown. We examined exhaled air dispersion during NIV using a human patient simulator reclined at 45° in a negative pressure room with 12 air changes/h by two different helmets via a ventilator and a total facemask via a bilevel positive airway pressure device. Exhaled air was marked by intrapulmonary smoke particles, illuminated by laser light sheet, and captured by a video camera for data analysis. Significant exposure was defined as where there was ≥ 20% of normalized smoke concentration. During NIV via a helmet with the simulator programmed in mild lung injury, exhaled air leaked through the neck-helmet interface with a radial distance of 150 to 230 mm when inspiratory positive airway pressure was increased from 12 to 20 cm H2O, respectively, while keeping the expiratory pressure at 10 cm H2O. During NIV via a helmet with air cushion around the neck, there was negligible air leakage. During NIV via a total facemask for mild lung injury, air leaked through the exhalation port to 618 and 812 mm when inspiratory pressure was increased from 10 to 18 cm H2O, respectively, with the expiratory pressure at 5 cm H2O. A helmet with a good seal around the neck is needed to prevent nosocomial infection during NIV for patients with respiratory infections.
The cost of pressure ulcers in the UK.
Bennett, Gerry; Dealey, Carol; Posnett, John
2004-05-01
To estimate the annual cost of treating pressure ulcers in the UK. Costs were derived from a bottom-up methodology, based on the daily resources required to deliver protocols of care reflecting good clinical practice. Health and social care system in the UK. Patients developing a pressure ulcer. A bottom-up costing approach is used to estimate treatment cost per episode of care and per patient for ulcers of different grades and level of complications. Also, total treatment cost to the health and social care system in the UK. The cost of treating a pressure ulcer varies from pound 1,064 (Grade 1) to pound 10,551 (Grade 4). Costs increase with ulcer grade because the time to heal is longer and because the incidence of complications is higher in more severe cases. The total cost in the UK is pound 1.4- pound 2.1 billion annually (4% of total NHS expenditure). Most of this cost is nurse time. Pressure ulcers represent a very significant cost burden in the UK. Without concerted effort this cost is likely to increase in the future as the population ages. To the extent that pressure ulcers are avoidable, pressure damage may be indicative of clinical negligence and there is evidence that litigation could soon become a significant threat to healthcare providers in the UK, as it is in the USA.
Mechanical support of total cavopulmonary connection with an axial flow pump.
Riemer, R Kirk; Amir, Gabriel; Reichenbach, Steven H; Reinhartz, Olaf
2005-08-01
Even under optimal circumstances, total cavopulmonary connection is associated with a continuous late risk of death. Hemodynamics are distinctly abnormal, with increased systemic venous pressures and frequent low cardiac output. Our study uses a sheep model of total cavopulmonary connection to test the response to axial flow pump (Thoratec HeartMate II; Thoratec Corporation (Pleasanton, Calif)) support of total cavopulmonary connection, which might be suitable to treat patients with failing Fontan circulation. Eight sheep (42-48 kg) were studied. After pilot studies in 3 animals, 5 underwent both pump-supported and nonsupported total cavopulmonary connection in alternating sequence for up to 2 hours. This was achieved with a 12-mm polytetrafluoroethylene graft from the (distally ligated) superior vena cava to the main pulmonary artery and a cannula placed in the inferior vena cava with an attached 16-mm Dacron graft to the main pulmonary artery. Pressures (arterial, inferior vena cava, left atrium, and pulmonary artery) and flows (ascending aorta and inferior vena cava) were recorded over 1 hour both with unsupported total cavopulmonary connection and after placing an axial flow pump (Thoratec HeartMate II) between the inferior vena caval inflow cannula and the main pulmonary artery. Under nonsupported total cavopulmonary connection circulation, inferior vena caval and aortic blood flow decreased by nearly 50%. Inferior vena caval pressure nearly doubled, whereas arterial pressure decreased by one third. Pulmonary artery pressure became nonpulsatile; however, mean pulmonary artery pressure and left atrial pressure did not change significantly. With pump-supported Fontan circulation, cardiac output, inferior vena caval flow, and arterial pressure returned to baseline. Inferior vena caval pressure decreased to below baseline levels. Mean pulmonary artery pressure and left atrial pressure again remained unchanged. Axial flow pump support from the inferior vena cava to the pulmonary artery can prevent the substantial decrease of aortic flow and pressure associated with total cavopulmonary connection and can reverse its poor hemodynamics. This is a simple model that can be used to further evaluate the potential of mechanical support as a treatment option in failing Fontan circulation.
Kantzow, Christina; Weuster-Botz, Dirk
2016-08-01
Low aqueous solubility of the gases for autotrophic fermentations (e.g., hydrogen gas) results in low productivities in bioreactors. A frequently suggested approach to overcome mass transfer limitation is to increase the solubility of the limiting gas in the reaction medium by increasing the partial pressure in the gas phase. An increased inlet hydrogen partial pressure of up to 2.1 bar (total pressure of 3.5 bar) was applied for the autotrophic conversion of hydrogen and carbon dioxide with Acetobacterium woodii in a batch-operated stirred-tank bioreactor with continuous gas supply. Compared to the autotrophic batch process with an inlet hydrogen partial pressure of 0.4 bar (total pressure of 1.0 bar) the final acetate concentration after 3.1 days was reduced to 50 % (29.2 g L(-1) compared to 59.3 g L(-1)), but the final formate concentration was increased by a factor of 18 (7.3 g L(-1) compared to 0.4 g L(-1)). Applying recombinant A. woodii strains overexpressing either genes for enzymes in the methyl branch of the Wood-Ljungdahl pathway or the genes phosphotransacetylase and acetate kinase at an inlet hydrogen partial pressure of 1.4 bar reduced the final formate concentration by up to 40 % and increased the final dry cell mass and acetate concentrations compared to the wild type strain. Solely the overexpression of the two genes for ATP regeneration at the end of the Wood-Ljungdahl pathway resulted in an initial switch off of formate production at increased hydrogen partial pressure until the maximum of the hydrogen uptake rate was reached.
Hastings, Mary K; Mueller, Michael J; Pilgram, Thomas K; Lott, Donovan J; Commean, Paul K; Johnson, Jeffrey E
2007-01-01
Standard prevention and treatment strategies to decrease peak plantar pressure include a total contact insert with a metatarsal pad, but no clear guidelines exist to determine optimal placement of the pad with respect to the metatarsal head. The purpose of this study was to determine the effect of metatarsal pad location on peak plantar pressure in subjects with diabetes mellitus and peripheral neuropathy. Twenty subjects with diabetes mellitus, peripheral neuropathy, and a history of forefoot plantar ulcers were studied (12 men and eight women, mean age=57+/-9 years). CT determined the position of the metatarsal pad relative to metatarsal head and peak plantar pressures were measured on subjects in three footwear conditions: extra-depth shoes and a 1) total contact insert, 2) total contact insert and a proximal metatarsal pad, and 3) total contact insert and a distal metatarsal pad. The change in peak plantar pressure between shoe conditions was plotted and compared to metatarsal pad position relative to the second metatarsal head. Compared to the total contact insert, all metatarsal pad placements between 6.1 mm to 10.6 mm proximal to the metatarsal head line resulted in a pressure reduction (average reduction=32+/-16%). Metatarsal pad placements between 1.8 mm distal and 6.1 mm proximal and between 10.6 mm proximal and 16.8 mm proximal to the metatarsal head line resulted in variable peak plantar pressure reduction (average reduction=16+/-21%). Peak plantar pressure increased when the metatarsal pad was located more than 1.8 mm distal to the metatarsal head line. Consistent peak plantar pressure reduction occurred when the metatarsal pad in this study was located between 6 to 11 mm proximal to the metatarsal head line. Pressure reduction lessened as the metatarsal pad moved outside of this range and actually increased if the pad was located too distal of this range. Computational models are needed to help predict optimal location of metatarsal pad with a variety of sizes, shapes, and material properties.
Physicochemical properties and antioxidant capacity of raw, roasted and puffed cacao beans.
Hu, SuJung; Kim, Byung-Yong; Baik, Moo-Yeol
2016-03-01
The antioxidant capacity and attributable bioactive compounds of puffed cacao beans were investigated. Roasting was carried out at 190°C for 15min and puffing was performed at 4-7kgf/cm(2). Cacao beans puffed at 4kgf/cm(2) showed the highest total polyphenols (23.16mgGAE/gsample) and total flavonoids (10.65mgCE/gsample) (p<0.05). As the puffing pressure increased, the amount of total polyphenols and total flavonoids decreased. The antioxidant capacity of cacao beans reflected the total polyphenols and flavonoids measured. The quantities of theobromine, catechin, epicatechin, and procyanidin B2 were higher in cacao beans puffed at 4kgf/cm(2) than in roasted cacao beans. Puffed cacao beans received a good sensory score in flavor, but sourness increased as puffing pressure increased. Thus, these results suggest that, in cacao bean processing, puffing could be an alternative to roasting, which provide a rich taste and high antioxidant capacity. Copyright © 2015 Elsevier Ltd. All rights reserved.
Neovius, Martin; Tynelius, Per; Rasmussen, Finn
2011-01-01
Objective To investigate the nature and magnitude of relations of systolic and diastolic blood pressures in late adolescence to mortality. Design Nationwide cohort study. Setting General community in Sweden. Participants Swedish men (n=1 207 141) who had military conscription examinations between 1969 and 1995 at a mean age of 18.4 years, followed up for a median of 24 (range 0-37) years. Main outcome measures Total mortality, cardiovascular mortality, and non-cardiovascular mortality. Results During follow-up, 28 934 (2.4%) men died. The relation of systolic blood pressure to total mortality was U shaped, with the lowest risk at a systolic blood pressure of about 130 mm Hg. This pattern was driven by the relation to non-cardiovascular mortality, whereas the relation to cardiovascular mortality was monotonically increasing (higher risk with higher blood pressure). The relation of diastolic blood pressure to mortality risk was monotonically increasing and stronger than that of systolic blood pressure, in terms of both relative risk and population attributable fraction (deaths that could be avoided if blood pressure was in the optimal range). Relations to cardiovascular and non-cardiovascular mortality were similar, with an apparent risk threshold at a diastolic blood pressure of about 90 mm Hg, below which diastolic blood pressure and mortality were unrelated, and above which risk increased steeply with higher diastolic blood pressures. Conclusions In adolescent men, the relation of diastolic blood pressure to mortality was more consistent than that of systolic blood pressure. Considering current efforts for earlier detection and prevention of risk, these observations emphasise the risk associated with high diastolic blood pressure in young adulthood. PMID:21343202
Comparison of measured and computed pitot pressures in a leading edge vortex from a delta wing
NASA Technical Reports Server (NTRS)
Murman, Earll M.; Powell, Kenneth G.
1987-01-01
Calculations are presented for a 75-deg swept flat plate wing tested at a freestream Mach number of 1.95 and 10 degrees angle of attack. Good agreement is found between computational data and previous experimental pitot pressure measurements in the core of the vortex, suggesting that the total pressure losses predicted by the Euler equation solvers are not errors, but realistic predictions. Data suggest that the magnitude of the total pressure loss is related to the circumferential velocity field through the vortex, and that it increases with angle of attack and varies with Mach number and sweep angle.
Effect of boattail geometry on the acoustics of parallel baffles in ducts
NASA Technical Reports Server (NTRS)
Soderman, P. T.; Unnever, G.; Dudley, M. R.
1984-01-01
Sound attenuation and total pressure drop of parallel duct baffles incorporating certain boattail geometries were measured in the NASA Ames Research Center 7- by 10-Foot Wind Tunnel. The baseline baffles were 1.56 m long and 20 cm thick, on 45-cm center-to-center spacings, and spanned the test section from floor to ceiling. Four different boattails were evaluated: a short, smooth (nonacoustic) boattail; a longer, smooth boattail; and two boattails with perforated surfaces and sound-absorbent filler. Acoustic measurements showed the acoustic boattails improved the sound attenuation of the baffles at approximately half the rate to be expected from constant-thickness sections of the same length; that is, 1.5 dB/n, where n is the ratio of acoustic treatment length to duct passage width between baffles. The aerodynamic total pressure loss was somewhat sensitive to tail geometry. Lengthening the tails to reduce the diffusion half-angle from 11 to 5 degrees reduced the total pressure loss approximately 9%. Perforating the boattails, which increased the surface roughness, did not have a large effect on the total pressure loss. Aerodynamic results are compared with a published empirical method for predicting baffle total pressure drop.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-15
... regulatory efforts and competitive pricing pressures. The Exchange proposes to increase both its SRO and DEA... lower total registration fees for off-Exchange traders to respond to competitive pressures. The Exchange... Exchange to respond to competitive pressures by lowering trader fees for all off-Exchange proprietary...
Experimental Investigation on Design Enhancement of Axial Fan Using Fixed Guide Vane
NASA Astrophysics Data System (ADS)
Munisamy, K. M.; Govindasamy, R.; Thangaraju, S. K.
2015-09-01
Airflow passes through the rotating blade in an axial flow fan will experience a helical flow pattern. This swirling effect leads the system to experience swirl energy losses or pressure drop yet reducing the total efficiency of the fan system. A robust tool to encounter this air spin past the blade is by introducing guide vane to the system. Owing to its importance, a new approach in designing outlet guide vane design for a commercial usage 1250mm diameter axial fan with a 30° pitch angle impeller has been introduced in this paper. A single line metal of proper curvature guide vane design technique has been adopted for this study. By choosing fan total efficiency as a target variable to be improved, the total and static pressure on the design point were set to be constraints. Therefore, the guide vane design was done based on the improvement target on the static pressure in system. The research shows that, with the improvement in static pressure by 29.63% through guide vane installation, the total fan efficiency is increased by 5.12%, thus reduces the fan power by 5.32%. Good agreement were found, that when the fan total efficiency increases, the power consumption of the fan is reduced. Therefore, this new approach of guide vane design can be applied to improve axial fan performance.
Improved solubilization of activated sludge by ozonation in pressure cycles.
Cheng, Chia-Jung; Hong, P K Andy; Lin, Cheng-Fang
2012-05-01
The generation of a large volume of activated sludge (AS) from wastewater treatment has increasingly become a great burden on the environment. Anaerobic digestion is routinely practiced for excess waste sludge; however, the process retention time is long because of kinetic limitation in the hydrolysis step. We tested the feasibility of applying ozone in pressure cycles to enhance the disintegration and solubilization of AS with the goal to prepare them for digestion using reduced ozone dose and contact time. The AS was subjected to repetitive pressure cycles in a closed vessel in which an ozone gas mixture was compressed into the slurry to reach 1040 kPa in the headspace to be followed by rapid venting. For a returned AS with total COD (tCOD) of 8200 mg L(-1), a dose of 0.01 gO(3)g(-1) total suspended solids (TSS) delivered via 20 pressure cycles within 16 min resulted in a 37-fold increase of the sCOD/tCOD ratio (due to increased soluble COD, i.e. sCOD) and a 25% reduction of TSS, in comparison to a dose of 0.08 gO(3)g(-1) TSS via bubbling contact over 15 min that resulted in a 15-fold increase of the sCOD/tCOD ratio and a 12% reduction of TSS. Sludge solubilization was evidenced by increased dissolved contents of total phosphorous (from 10 to 64 mg L(-1)), total nitrogen (from 14 to 120 mg L(-1)), and protein (from <15 to 39 mg L(-1)) in the sludge suspension after treatment, indicating significant solubilization of AS. Copyright © 2012 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Hung, R. J.; Liu, J. M.
1986-01-01
The distribution of atmospheric ozone is nonuniform both in space and time. Local ozone concentration vary with altitude, latitude, longitude, and season. Two year ozonesonde data, January 1981 to December 1982, observed at four Canadian stations and 2.5 year backscattered ultraviolet experiment data on the Nimbus-4 satellite, April 1970 to August 1972, observed over five American stations were used to study the relationship between the total ozone, vertical height distribution of the ozone mixing ratio, vertical height distribution of half total ozone, and the local tropopause height. The results show that there is a postive correlation between total ozone in Dobson Units and the tropopause height in terms of atmospheric pressure. This result suggests that local intrusion of the statosphere into the troposphere, or the local decreasing of tropopause height could occur if there is a local increasing of total ozone. A comparison of the vertical height distribution of the ozone mixing ratio, the modified pressure height of half total ozone and the tropopause height shows that the pressure height of an ozone mixing ratio of 0.3 micrograms/g, and the modified pressure height of half total ozone are very well correlated with the tropopause pressure height.
Passive control of base pressure on an axisymmetric blunt body using a perimetric slit
NASA Astrophysics Data System (ADS)
García de la Cruz, Juan Marcos; Oxlade, Anthony R.; Morrison, Jonathan F.
2017-04-01
The effect on the base pressure of a thin slit located at the base edge of a blunt axisymmetric body, communicating an internal cavity with the external flow, is investigated. A parametric study is performed of the effect on base pressure of changes in slit size and cavity depth. The base pressure increases initially with increasing cavity depth, but saturates at a depth which depends on the slit size. The base pressure increases monotonically up to 5 % with increasing slit size for the geometries tested. An upper limit of base pressure recovery of 20 % is extrapolated from the data. It is observed that the main effect of the slit is to reduce the instantaneous pressure asymmetry, which is linked to the total base pressure in a similar fashion for all the slit sizes. As a second-order effect, for highly asymmetric pressure distributions, the slit produces a base pressure increase not associated with the base pressure asymmetry. The results suggest a global effect of the slit on the wake due to a diametrical flow within the cavity driven by the pressure differences across the slit and regulated by the largest of the pressure drops between the slit and cavity. The slit also reduces the periodic base pressure fluctuations, corresponding mainly to the vortex shedding, and increases the rotational speed of the wake.
Tomaszewski, Maciej; White, Christobelle; Patel, Prashanth; Masca, Nicholas; Damani, Ravi; Hepworth, Joanne; Samani, Nilesh J; Gupta, Pankaj; Madira, Webster; Stanley, Adrian; Williams, Bryan
2014-01-01
Objectives Non-adherence to therapy is an important cause of suboptimal blood pressure control but few practical tools exist to accurately and routinely detect it. We used a simple urine-based assay to evaluate the prevalence of antihypertensive treatment non-adherence and its impact on blood pressure in a specialist hypertension centre. Methods 208 hypertensive patients (125 new referrals, 66 follow-up patients with inadequate blood pressure control and 17 renal denervation referrals) underwent assessment of antihypertensive drug intake using high-performance liquid chromatography-tandem mass spectrometry (HP LC-MS/MS) urine analysis at the time of clinical appointment. A total of 40 most commonly prescribed antihypertensive medications (or their metabolites) were screened for in spot urine samples. Results Overall, 25% of patients were totally or partially non-adherent to antihypertensive treatment (total non-adherence 10.1%, partial non-adherence 14.9%). The highest prevalence of partial and total non-adherence was among follow-up patients with inadequate blood pressure control (28.8%) and those referred for consideration of renal denervation (23.5%), respectively. There was a linear relationship between blood pressure and the numerical difference in detected/prescribed antihypertensive medications—every unit increase in this difference was associated with 3.0 (1.1) mm Hg, 3.1 (0.7) mm Hg and 1.9 (0.7) mm Hg increase in adjusted clinic systolic blood pressure, clinic diastolic blood pressure (DBP) and 24 h mean daytime DBP (p=0.0051, p=8.62×10−6, p=0.0057), respectively. Conclusions Non-adherence to blood pressure lowering therapy is common, particularly in patients with suboptimal blood pressure control and those referred for renal denervation. HP LC-MS/MS urine analysis could be used to exclude non-adherence and better stratify further investigations and intervention. PMID:24694797
Allaire, Robert; Muriuki, Muturi; Gilbertson, Lars; Harner, Christopher D
2008-09-01
Tears of the posterior root of the medial meniscus are becoming increasingly recognized. They can cause rapidly progressive arthritis, yet their biomechanical effects are not understood. The goal of this study was to determine the effects of posterior root tears of the medial meniscus and their repairs on tibiofemoral joint contact pressure and kinematics. Nine fresh-frozen cadaver knees were used. An axial load of 1000 N was applied with a custom testing jig at each of four knee-flexion angles: 0 degrees, 30 degrees, 60 degrees, and 90 degrees. The knees were otherwise unconstrained. Four conditions were tested: (1) intact, (2) a posterior root tear of the medial meniscus, (3) a repaired posterior root tear, and (4) a total medial meniscectomy. Fuji pressure-sensitive film was used to record the contact pressure and area for each testing condition. Kinematic data were obtained by using a robotic arm to record the position of the knees for each loading condition. Three-dimensional knee kinematics were analyzed with custom programs with use of previously described transformations. The measured variables were axial rotation, varus angulation, lateral translation, and anterior translation. In the medial compartment, a posterior root tear of the medial meniscus caused a 25% increase in peak contact pressure compared with that found in the intact condition (p < 0.001). Repair restored the peak contact pressure to normal. No difference was detected between the peak contact pressure after the total medial meniscectomy and that associated with the root tear. The peak contact pressure in the lateral compartment after the total medial meniscectomy was up to 13% greater than that for all other conditions (p = 0.026). Significant increases in external rotation and lateral tibial translation, compared with the values in the intact knee, were observed in association with the posterior root tear (2.98 degrees and 0.84 mm, respectively) and the meniscectomy (4.45 degrees and 0.80 mm, respectively), and these increases were corrected by the repair. This study demonstrated significant changes in contact pressure and knee joint kinematics due to a posterior root tear of the medial meniscus. Root repair was successful in restoring joint biomechanics to within normal conditions.
A postscript to Circulation of the blood: men and ideas.
Riley, R L
1982-10-01
Since 1964, when Fishman and Richards published Circulation of the Blood: Men and Ideas, Guyton's model of the circulation, in which mean circulatory pressure serves as the upstream pressure for venous return, has been extended, and the concept of vascular smooth muscle tone acting like the pressure surrounding a Starling resistor has been postulated. According to this scheme, the positive zero flow intercepts of rapidly determined arterial pressure-flow curves are the effective downstream pressures for arterial flow to different tissues. The arterioles, like Starling resistors, determine the downstream pressures and are followed by abrupt pressure drops, or "waterfalls." Capillary pressures are closely linked to those of the venules into which they flow. Capillary-venular pressures are the upstream pressures for venous return. In exercising muscles, reduced arteriolar tone lowers arteriolar pressure and increases arterial flow. This, in turn, raises capillary-venular pressure and increases venous flow. The arteriolar-capillary waterfall is decreased or eliminated. Total blood flow is increased by diversion of blood from tissues with slow venous drainage to muscles with fast venous drainage (low resistance X compliance). The heart pumps away the increased venous return by shifting to a new ventricular function curve.
Vortex Generators in a Two-Dimensional, External-Compression Supersonic Inlet
NASA Technical Reports Server (NTRS)
Baydar, Ezgihan; Lu, Frank K.; Slater, John W.
2016-01-01
Vortex generators within a two-dimensional, external-compression supersonic inlet for Mach 1.6 were investigated to determine their ability to increase total pressure recovery, reduce total pressure distortion, and improve the boundary layer. The vortex generators studied included vanes and ramps. The geometric factors of the vortex generators studied included height, length, spacing, and positions upstream and downstream of the inlet terminal shock. The flow through the inlet was simulated through the computational solution of the steady-state Reynolds-averaged Navier-Stokes equations on multi-block, structured grids. The vortex generators were simulated by either gridding the geometry of the vortex generators or modeling the vortices generated by the vortex generators. The inlet performance was characterized by the inlet total pressure recovery, total pressure distortion, and incompressible shape factor of the boundary-layer at the engine face. The results suggested that downstream vanes reduced the distortion and improved the boundary layer. The height of the vortex generators had the greatest effect of the geometric factors.
Prototype Development of an Implantable Compliance Chamber for a Total Artificial Heart.
Schmitz, Stephanie; Unthan, Kristin; Sedlaczek, Marc; Wald, Felix; Finocchiaro, Thomas; Spiliopoulos, Sotirios; Koerfer, Reiner; Steinseifer, Ulrich
2017-02-01
At our institute a total artificial heart is being developed. It is directly actuated by a linear drive in between two ventricles, which comprise membranes to separate the drive and blood flow. A compliance chamber (CC) is needed to reduce pressure peaks in the ventricles and to increase the pump capacity. Therefore, the movement of the membrane is supported by applying a negative pressure to the air volume inside the drive unit. This study presents the development of the implantable CC which is connected to the drive unit of the total artificial hearts (TAH). The anatomical fit of the CC is optimized by analyzing CT data and adapting the outer shape to ensure a proper fit. The pressure peaks are reduced by the additional volume and the flexible membrane of the CC. The validation measurements of change in pressure peaks and flow are performed using the complete TAH system connected to a custom mock circulation loop. Using the CC, the pressure peaks could be damped below 5 mm Hg in the operational range. The flow output was increased by up to 14.8% on the systemic side and 18.2% on the pulmonary side. The described implantable device can be used for upcoming chronic animal trials. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Mitchenere, P; Adrian, T E; Hobbs, K E; Bloom, S R
1981-03-01
The intraluminal gallbladder pressure has been measured in a conscious unsedated pig model by the use of a radiotelemetry pressure capsule. A loop fistula was incorporated to measure bile output simultaneously. Mean fasting intraluminal gallbladder pressure was found to be 15 +/- 4 mmHg above atmospheric pressure, and mean fasting bile output 7.5 +/- 0.8 ml/10 min. Following intravenous caerulein pressure peaked at 2 min with a mean rise of 17 +/- 3 mmHg above basal (P less than 0.005). Bile output was increased for 30 min following caerulein with a total mean increase for this period of 13.5 +/- 2.2 ml (P less than 0.005). Gallbladder pressure rose significantly 5 min after commencing a meal by 6.0 +/- 1.9 mmHg (P less than 0.025) reaching a peak pressure 65 min after the meal with a mean rise of 14.8 +/- 2.3 mmHg (P less than 0.005). Bile output was significantly increased for 50 min following the ingestion of food. The total increments above basal values for bile output being 15.9 +/- 2.7 ml (P less than 0.005) in the first 30 min post-prandially and 1.6 +/- 2.4 ml (P less than 0.005) in the 30--60 min period. This model re-emphasizes the rapidity of the hormonal response and may be valuable for further studies on the physiology of post-prandial gallbladder emptying.
Xenon excimer emission from pulsed high-pressure capillary microdischarges
NASA Astrophysics Data System (ADS)
Lee, Byung-Joon; Rahaman, Hasibur; Petzenhauser, Isfried; Frank, Klaus; Giapis, Konstantinos P.
2007-06-01
Intense xenon vacuum ultraviolet (VUV) emission is observed from a high-pressure capillary cathode microdischarge in direct current operation, by superimposing a high-voltage pulse of 50ns duration. Under stagnant gas conditions, the total VUV light intensity increases linearly with pressure from 400 to 1013mbar for a fixed voltage pulse. At fixed pressure, however, the VUV light intensity increases superlinearly with voltage pulse height ranging from 08to2.8kV. Gains in emission intensity are obtained by inducing gas flow through the capillary cathode, presumably because of excimer dimer survival due to gas cooling.
NASA Technical Reports Server (NTRS)
Meck, Janice V.; Martin, David S.; D'Aunno, Dominick S.; Waters, Wendy W.
2003-01-01
Intravenous injections of the indirect sympathetic amine, tyramine, are used as a test of peripheral adrenergic function. The authors measured the time course of increases in ejection fraction, heart rate, systolic and diastolic pressure, popliteal artery flow, and greater saphenous vein diameter before and after an injection of 4.0 mg/m(2) body surface area of tyramine in normal human subjects. The tyramine caused moderate, significant increases in systolic pressure and significant decreases in total peripheral resistance. The earliest changes were a 30% increase in ejection fraction and a 16% increase in systolic pressure, followed by a 60% increase in popliteal artery flow and a later 11% increase in greater saphenous vein diameter. There were no changes in diastolic pressure or heart rate. These results suggest that pressor responses during tyramine injections are primarily due to an inotropic response that increases cardiac output and pressure and causes a reflex decrease in vascular resistance. Thus, tyramine pressor tests are a measure of cardiac, but not vascular, sympathetic function.
Martinelli, Nicolo; Baretta, Silvia; Pagano, Jenny; Bianchi, Alberto; Villa, Tomaso; Casaroli, Gloria; Galbusera, Fabio
2017-11-25
Mobile-bearing ankle implants with good clinical results continued to increase the popularity of total ankle arthroplasty to address endstage ankle osteoarthritis preserving joint movement. Alternative solutions used fixed-bearing designs, which increase stability and reduce the risk of bearing dislocation, but with a theoretical increase of contact stresses leading to a higher polyethylene wear. The purpose of this study was to investigate the contact stresses, pressure and area in the polyethylene component of a new total ankle replacement with a fixed-bearing design, using 3D finite element analysis. A three-dimensional finite element model of the Zimmer Trabecular Metal Total Ankle was developed and assembled based on computed tomography images. Three different sizes of the polyethylene insert were modeled, and a finite element analysis was conducted to investigate the contact pressure, the von Mises stresses and the contact area of the polyethylene component during the stance phase of the gait cycle. The peak value of pressure was found in the anterior region of the articulating surface, where it reached 19.8 MPa at 40% of the gait cycle. The average contact pressure during the stance phase was 6.9 MPa. The maximum von Mises stress of 14.1 MPa was reached at 40% of the gait cycle in the anterior section. In the central section, the maximum von Mises stress of 10.8 MPa was reached at 37% of the gait cycle, whereas in the posterior section the maximum stress of 5.4 MPa was reached at the end of the stance phase. The new fixed-bearing total ankle replacement showed a safe mechanical behavior and many clinical advantages. However, advanced models to quantitatively estimate the wear are need. To the light of the clinical advantages, we conclude that the presented prosthesis is a good alternative to the other products present in the market.
Kim, Namsoo; Son, So-Hee; Maeng, Jin-Soo; Cho, Yong-Jin; Kim, Chong-Tai
2016-02-01
At specific conditions of high pressure, the stability and activity of some enzymes are reportedly known to increase. The aim of this study was to apply pressure-tolerant proteases to hydrolyzing anchovy fine powder (AFP) and to determine product characteristics of the resultant hydrolyzates. Anchovy fine powder enzyme hydrolyzates (AFPEHs) were produced at 300 MPa and ambient pressure using combinations of Flavourzyme 500MG, Alcalase 2.4L, Marugoto E and Protamex. When the same protease combination was used for hydrolysis, the contents of total soluble solids, total water-soluble nitrogen and trichloroacetic acid-soluble nitrogen in the AFPEHs produced at 300 MPa were conspicuously higher than those in the AFPEHs produced at ambient pressure. This result and electrophoretic characteristics indicated that the high-pressure process of this study accelerates protein hydrolysis compared with the ambient-pressure counterpart. Most peptides in the hydrolyzates obtained at 300 MPa had molecular masses less than 5 kDa. Functionality, sensory characteristics and the content of total free amino acids of selected hydrolyzates were also determined. The high-pressure hydrolytic process utilizing pressure-tolerant proteases was found to be an efficient method for producing protein hydrolyzates with good product characteristics. © 2015 Society of Chemical Industry.
Quantitative measurement of electron number in nanosecond and picosecond laser-induced air breakdown
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Yue; Sawyer, Jordan C.; Su, Liu
2016-05-07
Here we present quantitative measurements of total electron numbers in laser-induced air breakdown at pressures ranging from atmospheric to 40 bar{sub g} by 10 ns and 100 ps laser pulses. A quantifiable definition for the laser-induced breakdown threshold is identified by a sharp increase in the measurable total electron numbers via dielectric-calibrated coherent microwave scattering. For the 10 ns laser pulse, the threshold of laser-induced breakdown in atmospheric air is defined as the total electron number of ∼10{sup 6}. This breakdown threshold decreases with an increase of pressure and laser photon energy (shorter wavelength), which is consistent with the theory of initialmore » multiphoton ionization and subsequent avalanche processes. For the 100 ps laser pulse cases, a clear threshold is not present and only marginal pressure effects can be observed, which is due to the short pulse duration leading to stronger multiphoton ionization and minimal collisional avalanche ionization.« less
NASA Technical Reports Server (NTRS)
1973-01-01
A study has been made of possible ways to improve the performance of the Langley Research Center's Transonic Dynamics Tunnel (TDT). The major effort was directed toward obtaining increased dynamic pressure in the Mach number range from 0.8 to 1.2, but methods to increase Mach number capability were also considered. Methods studied for increasing dynamic pressure capability were higher total pressure, auxiliary suction, reducing circuit losses, reduced test medium temperature, smaller test section and higher molecular weight test medium. Increased Mach number methods investigated were nozzle block inserts, variable geometry nozzle, changes in test section wall configuration, and auxiliary suction.
Numerical Investigation of Vortex Generator Flow Control for External-Compression Supersonic Inlets
NASA Astrophysics Data System (ADS)
Baydar, Ezgihan
Vortex generators (VGs) within external-compression supersonic inlets for Mach 1.6 were investigated to determine their ability to increase total pressure recovery and reduce total pressure distortion. Ramp and vane-type VGs were studied. The geometric factors of interest included height, length, spacing, angle-of-incidence, and positions upstream and downstream of the inlet terminal shock. The flow through the inlet was simulated numerically through the solution of the steady-state, Reynolds-averaged Navier-Stokes equations on multi-block, structured grids using the Wind-US flow solver. The inlet performance was characterized by the inlet total pressure recovery and the radial and circumferential total pressure distortion indices at the engine face. Previous research of downstream VGs in the low-boom supersonic inlet demonstrated improvement in radial distortion up to 24% while my work on external-compression supersonic inlets improved radial distortion up to 86%, which is significant. The design of experiments and statistical analysis methods were applied to quantify the effect of the geometric factors of VGs and search for optimal VG arrays. From the analysis, VG angle-of-incidence and VG height were the most influential factors in increasing total pressure recovery and reducing distortion. The study on the two-dimensional external-compression inlet determined which passive flow control devices, such as counter-rotating vanes or ramps, reduce high distortion levels and improve the health of the boundary layer, relative to the baseline. Downstream vanes demonstrate up to 21% improvement in boundary layer health and 86% improvement in radial distortion. Upstream vanes demonstrated up to 3% improvement in boundary layer health and 9% improvement in radial distortion. Ramps showed no improvement in boundary layer health and radial distortion. Micro-VGs were preferred for their reduced viscous drag and improvement in total pressure recovery at the AIP. Although traditional VGs energize the flow with stronger vortex structures compared to micro-VGs, the AIP is affected with overwhelming amounts of reduced and enhanced flow regions. In summary, vanes are exceptional in reducing radial distortion and improving the health of the boundary layer compared to the ramps. In the study of the STEX inlet, vane-type vortex generators were the preferred devices for boundary layer flow control. In the supersonic diffuser, co-rotating vane arrays and counter-rotating vane arrays did not show improvement. In the subsonic diffuser, co-rotating vane arrays with negative angles-of-incidence and counter-rotating vane arrays were exceptional in reducing radial distortion and improving total pressure recovery. Downstream co-rotating vanes demonstrated up to 41% improvement in radial distortion whereas downstream counter-rotating vanes demonstrated up to 73% improvement. For downstream counter-rotating vanes, a polynomial trend between VG height and radial distortion indicate that increasing VG height improves inlet distortion. In summary, downstream vanes are exceptional in improving total pressure recovery compared to upstream vanes.
Self-Efficacy and Blood Pressure Self-Care Behaviors in Patients on Chronic Hemodialysis.
Kauric-Klein, Zorica; Peters, Rosalind M; Yarandi, Hossein N
2017-07-01
This study examined the effects of an educative, self-regulation intervention on blood pressure self-efficacy, self-care outcomes, and blood pressure control in adults receiving hemodialysis. Simple randomization was done at the hemodialysis unit level. One hundred eighteen participants were randomized to usual care ( n = 59) or intervention group ( n = 59). The intervention group received blood pressure education sessions and 12 weeks of individual counseling on self-regulation of blood pressure, fluid, and salt intake. There was no significant increase in self-efficacy scores within ( F = .55, p = .46) or between groups at 12 weeks ( F = 2.76, p = .10). Although the intervention was not successful, results from the total sample ( N = 118) revealed that self-efficacy was significantly related to a number of self-care outcomes including decreased salt intake, lower interdialytic weight gain, increased adherence to blood pressure medications, and fewer missed hemodialysis appointments. Increased blood pressure self-efficacy was also associated with lower diastolic blood pressure.
Publication pressure and scientific misconduct in medical scientists.
Tijdink, Joeri K; Verbeke, Reinout; Smulders, Yvo M
2014-12-01
There is increasing evidence that scientific misconduct is more common than previously thought. Strong emphasis on scientific productivity may increase the sense of publication pressure. We administered a nationwide survey to Flemish biomedical scientists on whether they had engaged in scientific misconduct and whether they had experienced publication pressure. A total of 315 scientists participated in the survey; 15% of the respondents admitted they had fabricated, falsified, plagiarized, or manipulated data in the past 3 years. Fraud was more common among younger scientists working in a university hospital. Furthermore, 72% rated publication pressure as "too high." Publication pressure was strongly and significantly associated with a composite scientific misconduct severity score. © The Author(s) 2014.
Adaptive Changes in Membrane Lipids of Barophilic Bacteria in Response to Changes in Growth Pressure
Yano, Yutaka; Nakayama, Akihiko; Ishihara, Kenji; Saito, Hiroaki
1998-01-01
The lipid compositions of barophilic bacterial strains which contained docosahexaenoic acid (DHA [22:6n-3]) were examined, and the adaptive changes of these compositions were analyzed in response to growth pressure. In the facultatively barophilic strain 16C1, phosphatidylethanolamine (PE) and phosphatidylglycerol (PG) were major components which had the same fatty acid chains. However, in PE, monounsaturated fatty acids such as hexadecenoic acid were major components, and DHA accounted for only 3.7% of the total fatty acids, while in PG, DHA accounted for 29.6% of the total fatty acids. In response to an increase in growth pressure in strain 16C1, the amounts of saturated fatty acids in PE were reduced, and these decreases were mainly balanced by an increase in unsaturated fatty acids, including DHA. In PG, the decrease in saturated fatty acids was mainly balanced by an increase in DHA. Similar adaptive changes in fatty acid composition were observed in response to growth pressure in obligately barophilic strain 2D2. Furthermore, these adaptive changes in response were also observed in response to low temperature in strain 16C1. These results confirm that the general shift from saturated to unsaturated fatty acids including DHA is one of the adaptive changes in response to increases in pressure and suggest that DHA may play a role in maintaining the proper fluidity of membrane lipids under high pressure. PMID:16349499
Moran, Andrew; Gu, Dongfeng; Zhao, Dong; Coxson, Pamela; Wang, Y. Claire; Chen, Chung-Shiuan; Liu, Jing; Cheng, Jun; Bibbins-Domingo, Kirsten; Shen, Yu-Ming; He, Jiang; Goldman, Lee
2010-01-01
Background The relative effects of individual and combined risk factor trends on future cardiovascular disease in China have not been quantified in detail. Methods and Results Future risk factor trends in China were projected based on prior trends. Cardiovascular disease (coronary heart disease and stroke) in adults ages 35 to 84 years was projected from 2010 to 2030 using the Coronary Heart Disease Policy Model–China, a Markov computer simulation model. With risk factor levels held constant, projected annual cardiovascular events increased by >50% between 2010 and 2030 based on population aging and growth alone. Projected trends in blood pressure, total cholesterol, diabetes (increases), and active smoking (decline) would increase annual cardiovascular disease events by an additional 23%, an increase of approximately 21.3 million cardiovascular events and 7.7 million cardiovascular deaths over 2010 to 2030. Aggressively reducing active smoking in Chinese men to 20% prevalence in 2020 and 10% prevalence in 2030 or reducing mean systolic blood pressure by 3.8 mm Hg in men and women would counteract adverse trends in other risk factors by preventing cardiovascular events and 2.9 to 5.7 million total deaths over 2 decades. Conclusions Aging and population growth will increase cardiovascular disease by more than a half over the coming 20 years, and projected unfavorable trends in blood pressure, total cholesterol, diabetes, and body mass index may accelerate the epidemic. National policy aimed at controlling blood pressure, smoking, and other risk factors would counteract the expected future cardiovascular disease epidemic in China. PMID:20442213
Experimental investigation of supersonic combustion in a strut-cavity based combustor
NASA Astrophysics Data System (ADS)
Sathiyamoorthy, K.; Danish, Tahzeeb Hassan; Srinivas, J.; Manjunath, P.
2018-07-01
Supersonic combustion was experimentally investigated in a strut-cavity based scramjet combustor with kerosene and pilot hydrogen as fuels. Strut-cavity is the space between two tandem struts in streamwise direction. The occurrence of cavity induced pressure oscillations in the strut-cavity was confirmed through cold flow experiments. The dominant modes of pressure oscillations were strongly influenced by the cavity aspect ratio. A ventilated rear wall (VRW), which is a new passive control device, was adopted in the strut-cavity. The strut-cavity with the VRW attenuated pressure oscillations better than the 'ramp rear wall' configuration. A scramjet combustor was realized with two strut-cavities in tandem for mixing enhancement and a strut-cavity with the VRW for flame stabilization. The combustor was tested at the following inlet conditions: total pressure of 4.89 bar, total temperature of 1517 K, and Mach number of 2. Supersonic combustion was observed. Steep increase in static pressure in the region of the strut-cavity with the VRW indicated that the flame was stabilized. The combustor was operated at a wide range of equivalence ratios (0.3-0.7) without inlet interactions. The total pressure at the combustor exit plane indicated that the flow was uniform, except at the central region. The total pressure loss and combustion efficiency of the combustor were evaluated for various equivalence ratios.
Methods and apparatus for reducing corrosion in refractory linings
Poeppel, Roger B.; Greenberg, Sherman; Diercks, Dwight R.
1987-01-01
Methods and apparatus are provided for reducing corrosion in a refractory lining of a liquid-containing vessel used in direct steelmaking processes. The vessel operates at between about 1600.degree. C. and about 1800.degree. C. and an oxygen partial pressure of about 10.sup.-12 atmospheres, creating slag which is rich in FeO. The refractory lining includes a significant level of chromium oxide (Cr.sub.2 O.sub.3), and has small interconnected pores which may be filled with a gas mixture having a higher total pressure and oxygen partial pressure than the total pressure and oxygen partial pressure associted with the liquid against the lining of the vessel. The gas mixture is forced through the pores of the lining so that the pores are continuously filled with the mixture. In this manner, the gas mixture creates a blanket which increases the oxygen partial pressure at the lining enough to maintain the chromium in the lining in a selected valence state in which the chromium has decreased solubility in the FeO slag, thereby reducing corrosion by the FeO and increasing the useful life of the refractory lining.
Shanlin, R J; Sole, M J; Rahimifar, M; Tator, C H; Factor, S M
1988-09-01
Intracranial pressure was increased in 59 rats by inflating a subdural balloon to a total mass volume of 0.3 ml. The increase in intracranial pressure ranged from 75 to greater than 500 mm Hg. With few exceptions, mean arterial pressure increased to as high as 227 mm Hg during the increase in intracranial pressure. Significant increases in plasma catecholamines, major electrocardiographic changes and a considerably shortened survival time were observed only in the rats that demonstrated an increase in mean arterial pressure greater than 50 mm Hg. A perfusion study with liquid silicone rubber (Microfil) revealed dilated irregular myocardial vessels with areas of focal constriction consistent with microvascular spasm. Histologic examination of the myocardium revealed widespread patches of contraction band necrosis and occasional contraction bands in the smooth muscle media of large coronary arteries. These observations suggest that myocardial damage after suddenly increased intracranial pressure resulted both from exposure to toxic levels of catecholamines and from myocardial reperfusion. Extension of these studies to humans suggests that a detailed assessment of myocardial function should be performed in victims of severe brain injury. Myocardial dysfunction may be a major determinant of the patient's prognosis or may render the heart unsuitable for transplantation.
Carbon dioxide exchange of lettuce plants under hypobaric conditions
NASA Technical Reports Server (NTRS)
Corey, K. A.; Bates, M. E.; Adams, S. L.; MacElroy, R. D. (Principal Investigator)
1996-01-01
Growth of plants in a Controlled Ecological Life Support System (CELSS) may involve the use of hypobaric pressures enabling lower mass requirements for atmospheres and possible enhancement of crop productivity. A controlled environment plant growth chamber with hypobaric capability designed and built at Ames Research Center was used to determine if reduced pressures influence the rates of photosynthesis (Ps) and dark respiration (DR) of hydroponically grown lettuce plants. The chamber, referred to as a plant volatiles chamber (PVC), has a growing area of about 0.2 m2, a total gas volume of about 0.7 m3, and a leak rate at 50 kPa of <0.1%/day. When the pressure in the chamber was reduced from ambient to 51 kPa, the rate of net Ps increased by 25% and the rate of DR decreased by 40%. The rate of Ps increased linearly with decreasing pressure. There was a greater effect of reduced pressure at 41 Pa CO2 than at 81 Pa CO2. This is consistent with reports showing greater inhibition of photorespiration (Pr) in reduced O2 at low CO2 concentrations. When the partial pressure of O2 was held constant but the total pressure was varied between 51 and 101 kPa, the rate of CO2 uptake was nearly constant, suggesting that low pressure enhancement of Ps may be mainly attributable to lowered partial pressure of O2 and the accompanying reduction in Pr. The effects of lowered partial pressure of O2 on Ps and DR could result in substantial increases in the rates of biomass production, enabling rapid throughput of crops or allowing flexibility in the use of mass and energy resources for a CELSS.
Maturation of heart rate and blood pressure variability during sleep in term-born infants.
Yiallourou, Stephanie R; Sands, Scott A; Walker, Adrian M; Horne, Rosemary S C
2012-02-01
Abnormal blood pressure control is implicated in the sudden infant death syndrome (SIDS). However, no data exist on normal development of blood pressure control during infancy. This study assessed maturation of autonomic control of blood pressure and heart rate during sleep within the first 6 months of life. Term infants (n = 31) were studied longitudinally at 2-4 weeks, 2-3 months, and 5-6 months postnatal age. Infants underwent daytime polysomnography at each age studied. Blood pressure and heart rate were recorded during quiet (QS) and active (AS) sleep in undisturbed baseline and head-up tilt conditions. Autonomic control was assessed using spectral indices of blood pressure and heart rate variability (BPV and HRV) in ranges of low frequency (LF, reflecting sympathetic + parasympathetic activity) and high frequency (HF, parasympathetic activity), total power (LF+HF), and LF/HF ratio (sympathovagal balance). With increasing postnatal age and predominantly during QS, HRV-LF, HRV-HF, and HRV total power increased, while HRV-LF/HF decreased. BPV-LF/HF also decreased with postnatal age. All changes were evident in both baseline and head-up tilt conditions. BPV-LF and BPV total power during tilts were markedly reduced in QS versus AS at each age. In sleeping infants, sympathetic vascular modulation of the circulation decreases with age, while parasympathetic control of heart rate is strengthened. These normative data will aid in the early identification of conditions where autonomic function is impaired, such as in SIDS.
Effects of Ultrasound on Extraction of Saponin from Ginseng
NASA Astrophysics Data System (ADS)
Li, Hui; Ohdaira, Etsuzo; Ide, Masao
1994-05-01
We performed a study of the effects of ultrasound on the extraction of saponin from Panax ginseng C. A. Meyer. In this study, the extraction of saponin was examined as functions of irradiation time (0.5 to 6 h) and acoustic pressure (0 to 90 kPa). It has been observed that the yields of both total extract and saponin are larger with ultrasonic irradiation than those without ultrasonic irradiation; the increase in yield of total extract is approximately 15 wt%, and that of saponin is approximately 30 wt% at an acoustic pressure 67 kPa. In addition, the yield increases with the acoustic pressure. It is also demonstrated that saponin was not resolved in the acoustic intensity range of this experiment. The enhancement in liquid-solid extraction caused by ultrasound can be attributed to the phenomenon of cavitation.
NASA Technical Reports Server (NTRS)
Russin, W. R.
1974-01-01
Tests were conducted to determine the performance of a hydrogen burner used to produce a test gas that simulates air entering a scramjet combustor at various flight conditions. The test gas simulates air in that it duplicates the total temperature, total pressure, and the volume fraction of oxygen of air at flight conditions. The main objective of the tests was to determine the performance of the burner as a function of the effective exhaust port area. The conclusions were: (1) pressure oscillations of the chugging type were reduced in amplitude to plus or minus 2 percent of the mean pressure level by proper sizing of hydrogen, oxygen, and air injector flow areas; (2) combustion efficiency remained essentially constant as the exhaust port area was increased by a factor of 3.4; (3) the mean total temperature determined from integrating the exit radial gas property profiles was within plus or minus 5 percent of the theoretical bulk total temperature; (4) the measured exit total temperature profile had a local peak temperature more than 30 percent greater than the theoretical bulk total temperature; and (5) measured heat transfer to the burner liner was 75 percent of that predicted by theory based on a flat radial temperature profile.
Satoh, Michihiro; Ohkubo, Takayoshi; Asayama, Kei; Murakami, Yoshitaka; Sakurai, Masaru; Nakagawa, Hideaki; Iso, Hiroyasu; Okayama, Akira; Miura, Katsuyuki; Imai, Yutaka; Ueshima, Hirotsugu; Okamura, Tomonori
2015-03-01
No large-scale, longitudinal studies have examined the combined effects of blood pressure (BP) and total cholesterol levels on long-term risks for subtypes of cardiovascular death in an Asian population. To investigate these relationships, a meta-analysis of individual participant data, which included 73 916 Japanese subjects (age, 57.7 years; men, 41.1%) from 11 cohorts, was conducted. During a mean follow-up of 15.0 years, deaths from coronary heart disease, ischemic stroke, and intraparenchymal hemorrhage occurred in 770, 724, and 345 cases, respectively. Cohort-stratified Cox proportional hazard models were used. After stratifying the participants by 4 systolic BP ×4 total cholesterol categories, the group with systolic BP ≥160 mm Hg with total cholesterol ≥5.7 mmol/L had the greatest risk for coronary heart disease death (adjusted hazard ratio, 4.39; P<0.0001 versus group with systolic BP <120 mm Hg and total cholesterol <4.7 mmol/L). The adjusted hazard ratios of systolic BP (per 20 mm Hg) increased with increases in total cholesterol categories (hazard ratio, 1.52; P<0.0001 in group with total cholesterol ≥5.7 mmol/L). Similarly, the adjusted hazard ratios of total cholesterol increased with increases in systolic BP categories (P for interaction ≤0.04). Systolic BP was positively associated with ischemic stroke and intraparenchymal hemorrhage death, and total cholesterol was inversely associated with intraparenchymal hemorrhage, but no significant interactions between BP and total cholesterol were observed for stroke. High BP and high total cholesterol can synergistically increase the risk for coronary heart disease death but not for stroke in the Asian population. © 2015 American Heart Association, Inc.
Mechanical behavior, electronic and phonon properties of ZrB12 under pressure
NASA Astrophysics Data System (ADS)
Li, Xiao-Hong; Yong, Yong-Liang; Cui, Hong-Ling; Zhang, Rui-Zhou
2018-06-01
The mechanical, phonon and electronic properties of ZrB12 under pressure are investigated by first-principles calculations. The research shows that ZrB12 is mechanically and dynamically stable up to 100 GPa. The elastic constants, bulk modulus B, shear modulus G, hardness Hv, B/G ratio, Debye temperature under different pressures are systematically investigated. The calculation of electronic properties shows that ZrB12 has metallic character. The Zr-d states dominate the DOS at the Fermi level, and the total DOS and PDOS change slightly with the increasing pressure. DOS (Ef) first decreases, then increases with the increasing pressure. At 50 GPa, ZrB12 has less electron carriers. The analysis of electron localization function shows that the strong B-B and Zr-B covalent bonds may be responsible for the high hardness and stability.
Vapor pressure and vapor fractionation of silicate melts of tektite composition
Walter, Louis S.; Carron, M.K.
1964-01-01
The total vapor pressure of Philippine tektite melts of approximately 70 per cent silica has been determined at temperatures ranging from 1500 to 2100??C. This pressure is 190 ?? 40 mm Hg at 1500??C, 450 ?? 50 mm at 1800??C and 850 ?? 70 mm at 2100?? C. Determinations were made by visually observing the temperature at which bubbles began to form at a constant low ambient pressure. By varying the ambient pressure, a boiling point curve was constructed. This curve differs from the equilibrium vapor pressure curve due to surface tension effects. This difference was evaluated by determining the equilibrium bubble size in the melt and calculating the pressure due to surface tension, assuming the latter to be 380 dyn/cm. The relative volatility from tektite melts of the oxides of Na, K, Fe, Al and Si has been determined as a function of temperature, total pressure arid roughly, of oxygen fugacity. The volatility of SiO2 is decreased and that of Na2O and K2O is increased in an oxygen-poor environment. Preliminary results indicate that volatilization at 2100??C under atmospheric pressure caused little or no change in the percentage Na2O and K2O. The ratio Fe3 Fe2 of the tektite is increased in ambient air at a pressure of 9 ?? 10-4 mm Hg (= 106.5 atm O2, partial pressure) at 2000??C. This suggests that tektites were formed either at lower oxygen pressures or that they are a product of incomplete oxidation of parent material with a still lower ferricferrous ratio. ?? 1964.
Effects of the lapidus arthrodesis and chevron bunionectomy on plantar forefoot pressures.
King, Christy M; Hamilton, Graham A; Ford, Lawrence A
2014-01-01
Hallux valgus with or without first ray insufficiency has been strongly implicated as a contributing factor in lesser metatarsal overload. The principle goals of a bunionectomy are to relieve the pain, correct the deformity, and restore first metatarsophalangeal joint congruity. Until now, little evidence has been available to assess the effects of bunionectomy procedures on forefoot pressure. The primary aim of the present prospective study was to evaluate the preoperative and postoperative plantar pressures after 2 specific bunionectomies: the chevron bunionectomy and Lapidus arthrodesis. A total of 68 subjects, 34 in each group, were included for radiographic and pedographic evaluation. Both procedures demonstrated radiographic improvements in the mean intermetatarsal and hallux abductus angles. The mean hallux plantar pressure decreased significantly in both procedure groups (p < .001). However, Lapidus group exhibited an increase in the mean fifth metatarsal head plantar pressure (p = .008) and pressure under the fifth metatarsal as a percentage of the total forefoot pressure (p = .01). Furthermore, the pressure under the second metatarsal as a percentage of the total forefoot pressure decreased significantly (p = .01). This study suggests that the Lapidus arthrodesis and chevron bunionectomy both provide correction for hallux valgus deformity, but when comparing forefoot load sharing pressures, the Lapidus arthrodesis appeared to have greater influence on the load sharing distribution of forefoot pressure than did the bunionectomy employing the chevron osteotomy. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Kaushik, Neelima; Kaur, Barjinder P; Rao, P Srinivasa
2014-10-01
This study attempts to report the effect of high pressure processing (100, 200 and 300 MPa for 5, 10 and 15 min at 27 ± 2 ℃) on quality and shelf life extension of 'Bombai' variety peeled litchi fruits during refrigerated storage (5 ℃). High pressure processing significantly increased total colour difference, browning index, drip loss and total soluble solids, whereas pH decreased after processing. Also, ascorbic acid content significantly decreased after high pressure processing and retention of 83.5% was observed. Texture profile analysis showed that pressurization significantly affected firmness and increased cohesiveness, gumminess, springiness and chewiness of litchi fruits. Pressure-induced firming effect was observed at 100 and 200 MPa pressure. A maximum of 3.29, 3.24 and 3.77 log10 cycles reduction in aerobic mesophiles, yeast & mold and psychrotrophs count, respectively, was achieved after pressurization of 300 MPa for 10 and 15 min treatments. During storage, samples treated at 300 MPa for 10 and 15 min showed relatively minimal changes in physico-chemical attributes, textural parameters and maintained lower viable microbial counts. Treatments at 300 MPa for 10 min and 15 min were found to enhance the shelf life of litchi fruits up to 32 days as compared to 12 days of untreated during refrigerated storage (5 ℃). © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Combining liquid inertia with pressure recovery from bubble expansion for enhanced flow boiling
NASA Astrophysics Data System (ADS)
Kalani, A.; Kandlikar, S. G.
2015-11-01
In this paper, we demonstrate using liquid inertia force in a taper gap microchannel geometry to provide a high level of heat dissipation capacity accompanied by a high heat transfer coefficient and low pressure drop during flow boiling. The high mass flux increases liquid inertia force and promotes vapor removal from the manifold, thereby increasing critical heat flux (CHF) and heat transfer coefficient. The tapered gap above the microchannels provides an increasing cross-sectional area in the flow direction. This gap allows bubbles to emerge from microchannels and expand within the gap along the flow direction. The bubble evaporation and expansion in tapered gap causes pressure recovery and reduces the total pressure drop. The pressure recovery increases with the increased evaporation rate at higher heat fluxes. Using a 6% taper and a moderately high inlet liquid flow Reynolds number of 1095, we have reached a CHF of 1.07 kW/cm2 with a heat transfer coefficient of 295 kW/m2 °C and a pressure drop of 30 kPa.
Effects of long-term low atmospheric pressure on gas exchange and growth of lettuce
NASA Astrophysics Data System (ADS)
Tang, Yongkang; Guo, Shuangsheng; Dong, Wenping; Qin, Lifeng; Ai, Weidang; Lin, Shan
2010-09-01
The objectives of this research were to determine photosynthesis, evapotranspiration and growth of lettuce at long-term low atmospheric pressure. Lettuce ( Lactuca sativa L . cv. Youmaicai) plants were grown at 40 kPa total pressure (8.4 kPa p) or 101 kPa total pressure (20.9 kPa p) from seed to harvest for 35 days. Germination rate of lettuce seeds decreased by 7.6% at low pressure, although this was not significant. There was no significant difference in crop photosynthetic rate between hypobaria and ambient pressure during the 35-day study. The crop evapotranspiration rate was significantly lower at low pressure than that at ambient pressure from 20 to 30 days after planting (DAP), but it had no significant difference before 20 DAP or after 30 DAP. The growth cycle of lettuce plants at low pressure was delayed. At low pressure, lettuce leaves were curly at the seedling stage and this disappeared gradually as the plants grew. Ambient lettuce plants were yellow and had an epinastic growth at harvest. The shoot height, leaf number, leaf length and shoot/root ratio were lower at low pressure than those at ambient pressure, while leaf area and root growth increased. Total biomass of lettuce plants grown at two pressures had no significant difference. Ethylene production at low pressure decreased significantly by 38.8% compared with ambient pressure. There was no significant difference in microelements, nutritional phytochemicals and nitrate concentrations at the two treatments. This research shows that lettuce can be grown at long-term low pressure (40 kPa) without significant adverse effects on seed germination, gas exchange and plant growth. Furthermore, ethylene release was reduced in hypobaria.
Gebreyes, Yeweyenhareg Feleke; Goshu, Dejuma Yadeta; Geletew, Tedla Kebede; Argefa, Terefe Gelibo; Zemedu, Theodros Getachew; Lemu, Kassahun Amenu; Waka, Feyissa Challa; Mengesha, Alemayehu Bekele; Degefu, Fasil Shiferaw; Deghebo, Atkure Defar; Wubie, Habtamu Teklie; Negeri, Mussie Gebremichael; Tesema, Tefera Tadele; Tessema, Yabetse Girma; Regassa, Mulugeta Guta; Eba, Geremew Gonfa; Beyene, Misrak Getnet; Yesu, Kissi Mudie; Zeleke, Girum Taye; Mengistu, Yewondwossen Tadesse; Belayneh, Abebe Bekele
2018-01-01
The prevalence of diabetes, dyslipidemias, and high blood pressure is increasing worldwide especially in low and middle income countries. World Health Organization has emphasized the importance of the assessment of the magnitude of the specific disease in each country. We determined the prevalence and determinant factors of high blood pressure, hyperglycemia, dyslipidemias and metabolic syndrome in Ethiopia. A community based survey was conducted from -April to June 2015 using WHO NCD STEPS instrument version 3.1. 2008. Multistage stratified systemic random sampling was used to select representative samples from 9 regions of the country. A total of 10,260 people aged 15-69 years participated in the study. Blood pressure (BP) was measured for 9788 individuals. A total of 9141 people underwent metabolic screening. The prevalence of raised blood pressure (SBP ≥140 and/or DBP ≥ 90 mmHg) was 15.8% (16.3% in females and 15.5% in males). The prevalence of diabetes mellitus (FBS ≥ 126 mg /dl) including those on medication was 3.2% (3.5% males and 3.0% females). The prevalence of impaired fasting glucose was 9.1% with ADA criteria and 3.8% with WHO criteria. Hypercholesterolemia was found in 5.2%, hypertriglyceridemia in 21.0%, high LDL cholesterol occurred in 14.1% and low HDL cholesterol occurred in 68.7%. The prevalence of metabolic syndrome using IDF definition was 4.8% (8.6% in females and vs. 1.8% in males). Advanced age, urban residence, lack of physical exercise, raised waist circumference, raised waist hip ratio, overweight or obesity, and total blood cholesterol were significantly associated with raised blood pressure (BP) and diabetes mellitus. Increased waist- hip ratio was an independent predictor of raised blood pressure, hyperglycemia and raised total cholesterol. Our study showed significantly high prevalence of raised blood pressure, hyperglycemia and dyslipidemia in Ethiopia. Community based interventions are recommended to control these risk factors.
NASA Astrophysics Data System (ADS)
Berdanier, Reid Adam
The effect of rotor tip clearances in turbomachinery applications has been a primary research interest for nearly 80 years. Over that time, studies have shown increased tip clearance in axial flow compressors typically has a detrimental effect on overall pressure rise capability, isentropic efficiency, and stall margin. With modern engine designs trending toward decreased core sizes to increase propulsive efficiency (by increasing bypass ratio) or additional compression stages to increase thermal efficiency by increasing the overall pressure ratio, blade heights in the rear stages of the high pressure compressor are expected to decrease. These rear stages typically feature smaller blade aspect ratios, for which endwall flows are more important, and the rotor tip clearance height represents a larger fraction of blade span. As a result, data sets collected with large relative rotor tip clearance heights are necessary to facilitate these future small core design goals. This research seeks to characterize rotor tip leakage flows for three tip clearance heights in the Purdue three-stage axial compressor facility (1.5%, 3.0%, and 4.0% as a percentage of overall annulus height). The multistage environment of this compressor provides the unique opportunity to examine tip leakage flow effects due to stage matching, stator-rotor interactions, and rotor-rotor interactions. The important tip leakage flow effects which develop as a result of these interactions are absent for previous studies which have been conducted using single-stage machines or isolated rotors. A series of compressor performance maps comprise points at four corrected speeds for each of the three rotor tip clearance heights. Steady total pressure and total temperature measurements highlight the effects of tip leakage flows on radial profiles and wake shapes throughout the compressor. These data also evaluate tip clearance effects on efficiency, stall margin, and peak pressure rise capability. An emphasis of measurements collected at these part-speed and off-design conditions provides a unique data set for calibrating computational models and predictive algorithms. Further investigations with detailed steady total pressure traverses provide additional insight to tip leakage flow effects on stator performance. A series of data on the 100% corrected speedline further characterize the tip leakage flow using time-resolved measurements from a combination of instrumentation techniques. An array of high-frequency-response piezoresistive pressure transducers installed over the rotors allows quantification of tip leakage flow trajectories. These data, along with measurements from a fast-response total pressure probe downstream of the rotors, evaluate the development of tip leakage flows and assess the corresponding effects of upstream stator wakes. Finally, thermal anemometry measurements collected using the single slanted hot-wire technique evaluate three-dimensional velocity components throughout the compressor. These data facilitate calculations of several flow metrics, including a blockage parameter and phase-locked streamwise vorticity.
Blood flow vs. venous pressure effects on filtration coefficient in oleic acid-injured lung.
Anglade, D; Corboz, M; Menaouar, A; Parker, J C; Sanou, S; Bayat, S; Benchetrit, G; Grimbert, F A
1998-03-01
On the basis of changes in capillary filtration coefficient (Kfc) in 24 rabbit lungs, we determined whether elevations in pulmonary venous pressure (Ppv) or blood flow (BF) produced differences in filtration surface area in oleic acid-injured (OA) or control (Con) lungs. Lungs were cyclically ventilated and perfused under zone 3 conditions by using blood and 5% albumin with no pharmacological modulation of vascular tone. Pulmonary arterial, venous, and capillary pressures were measured by using arterial, venous, and double occlusion. Before and during each Kfc-measurement maneuver, microvascular/total vascular compliance was measured by using venous occlusion. Kfc was measured before and 30 min after injury, by using a Ppv elevation of 7 cmH2O or a BF elevation from 1 to 2 l . min-1 . 100 g-1 to obtain a similar double occlusion pressure. Pulmonary arterial pressure increased more with BF than with Ppv in both Con and OA lungs [29 +/- 2 vs. 19 +/- 0.7 (means +/- SE) cmH2O; P < 0. 001]. In OA lungs compared with Con lungs, values of Kfc (200 +/- 40 vs. 83 +/- 14%, respectively; P < 0.01) and microvascular/total vascular compliance ratio (86 +/- 4 vs. 68 +/- 5%, respectively; P < 0.01) increased more with BF than with Ppv. In conclusion, for a given OA-induced increase in hydraulic conductivity, BF elevation increased filtration surface area more than did Ppv elevation. The steep pulmonary pressure profile induced by increased BF could result in the recruitment of injured capillaries and could also shift downstream the compression point of blind (zone 1) and open injured vessels (zone 2).
NASA Astrophysics Data System (ADS)
Mahdavi, Amirhossein; McDonald, André
2018-02-01
The final quality of cold-sprayed coatings can be significantly influenced by gas-substrate heat exchange, due to the dependence of the deposition efficiency of the particles on the substrate temperature distribution. In this study, the effect of the air temperature and pressure, as process parameters, and surface roughness and thickness, as substrate parameters, on the convective heat transfer coefficient of the impinging air jet was investigated. A low-pressure cold spraying unit was used to generate a compressed air jet that impinged on a flat substrate. A comprehensive mathematical model was developed and coupled with experimental data to estimate the heat transfer coefficient and the surface temperature of the substrate. The effect of the air total temperature and pressure on the heat transfer coefficient was studied. It was found that increasing the total pressure would increase the Nusselt number of the impinging air jet, while total temperature of the air jet had negligible effect on the Nusslet number. It was further found that increasing the roughness of the substrate enhanced the heat exchange between the impinging air jet and the substrate. As a result, higher surface temperatures on the rough substrate were measured. The study of the effect of the substrate thickness on the heat transfer coefficient showed that the Nusselt number that was predicted by the model was independent of the thickness of the substrate. The surface temperature profile, however, decreased in increasing radial distances from the stagnation point of the impinging jet as the thickness of the substrate increased. The results of the current study were aimed to inform on the influence and effect of substrate and process parameters on the gas-substrate heat exchange and the surface temperature of the substrate on the final quality of cold-sprayed coatings.
de Vries, Durk R; van Herwaarden, Margot A; Smout, André J P M; Samsom, Melvin
2008-06-01
The roles of intragastric pressure (IGP), intraesophageal pressure (IEP), gastroesophageal pressure gradient (GEPG), and body mass index (BMI) in the pathophysiology of gastroesophageal reflux disease (GERD) and hiatal hernia (HH) are only partly understood. In total, 149 GERD patients underwent stationary esophageal manometry, 24-h pH-metry, and endoscopy. One hundred three patients had HH. Linear regression analysis showed that each kilogram per square meter of BMI caused a 0.047-kPa increase in inspiratory IGP (95% confidence interval [CI] 0.026-0.067) and a 0.031-kPa increase in inspiratory GEPG (95% CI 0.007-0.055). Each kilogram per square meter of BMI caused expiratory IGP to increase with 0.043 kPa (95% CI 0.025-0.060) and expiratory IEP with 0.052 kPa (95% CI 0.027-0.077). Each added year of age caused inspiratory IEP to decrease by 0.008 kPa (95% CI -0.015-0.001) and inspiratory GEPG to increase by 0.008 kPa (95% CI 0.000-0.015). In binary logistic regression analysis, HH was predicted by inspiratory and expiratory IGP (odds ratio [OR] 2.93 and 2.62, respectively), inspiratory and expiratory GEPG (OR 3.19 and 2.68, respectively), and BMI (OR 1.72/5 kg/m(2)). In linear regression analysis, HH caused an average 5.09% increase in supine acid exposure (95% CI 0.96-9.22) and an average 3.46% increase in total acid exposure (95% CI 0.82-6.09). Each added year of age caused an average 0.10% increase in upright acid exposure and a 0.09% increase in total acid exposure (95% CI 0.00-0.20 and 0.00-0.18). BMI predicts IGP, inspiratory GEPG, and expiratory IEP. Age predicts inspiratory IEP and GEPG. Presence of HH is predicted by IGP, GEPG, and BMI. GEPG is not associated with acid exposure.
Efficiency and Pressure Loss Characteristics of an Ultra-Compact Combustor with Bulk Swirl
2007-06-01
al., 2004a:3). Besides offering size and weight reductions, the UCC opens the door to adding a reheat step to the Brayton cycle currently used in...possible include a reheat step in the Brayton cycle to gain enhanced performance. Sirignano and Liu (Sirignano and Liu, 1998:1-2) pioneered the idea of...increase in speed for a subsonic flow resulting in a given loss in total pressure. This pressure loss is not desired in the constant pressure Brayton
Maturation of Heart Rate and Blood Pressure Variability during Sleep in Term-Born Infants
Yiallourou, Stephanie R.; Sands, Scott A.; Walker, Adrian M.; Horne, Rosemary S.C.
2012-01-01
Study Objectives: Abnormal blood pressure control is implicated in the sudden infant death syndrome (SIDS). However, no data exist on normal development of blood pressure control during infancy. This study assessed maturation of autonomic control of blood pressure and heart rate during sleep within the first 6 months of life. Participants: Term infants (n = 31) were studied longitudinally at 2-4 weeks, 2-3 months, and 5-6 months postnatal age. Interventions: Infants underwent daytime polysomnography at each age studied. Blood pressure and heart rate were recorded during quiet (QS) and active (AS) sleep in undisturbed baseline and head-up tilt conditions. Measurements and Results: Autonomic control was assessed using spectral indices of blood pressure and heart rate variability (BPV and HRV) in ranges of low frequency (LF, reflecting sympathetic + parasympathetic activity) and high frequency (HF, parasympathetic activity), total power (LF+HF), and LF/HF ratio (sympathovagal balance). With increasing postnatal age and predominantly during QS, HRV-LF, HRV-HF, and HRV total power increased, while HRV-LF/HF decreased. BPV-LF/HF also decreased with postnatal age. All changes were evident in both baseline and head-up tilt conditions. BPV-LF and BPV total power during tilts were markedly reduced in QS versus AS at each age. Conclusions: In sleeping infants, sympathetic vascular modulation of the circulation decreases with age, while parasympathetic control of heart rate is strengthened. These normative data will aid in the early identification of conditions where autonomic function is impaired, such as in SIDS. Citation: Yiallourou SR; Sands SA; Walker AM; Horne RSC. Maturation of heart rate and blood pressure variability during sleep in term-born infants. SLEEP 2012;35(2):177-186. PMID:22294807
Pressure changes in the plasma sheet during substorm injections
NASA Technical Reports Server (NTRS)
Kistler, L. M.; Moebius, E.; Baumjohann, W.; Paschmann, G.; Hamilton, D. C.
1992-01-01
Data from the CHEM instrument on AMPTE CCE, data from the 3D plasma instrument and the SULEICA instrument on AMPTE IRM, and magnetometer data from both spacecraft are used to determine the particle pressure and total pressure as a function of radial distance in the plasma sheet for periods before and after the onset of substorm-associated ion enhancements over the range 7-19 RE. Events were chosen that occurred during times of increasing magnetospheric activity, as determined by an increasing AE index, in which a sudden increase, or 'injection', of energetic particle flux is observed. It is shown that the simultaneous appearance of energetic particles and changes in the magnetic field results naturally from pressure balance and does not necessarily indicate that the local changing field is accelerating the particles.
Arctic Ocean Freshwater Content and Its Decadal Memory of Sea-Level Pressure
NASA Astrophysics Data System (ADS)
Johnson, Helen L.; Cornish, Sam B.; Kostov, Yavor; Beer, Emma; Lique, Camille
2018-05-01
Arctic freshwater content (FWC) has increased significantly over the last two decades, with potential future implications for the Atlantic meridional overturning circulation downstream. We investigate the relationship between Arctic FWC and atmospheric circulation in the control run of a coupled climate model. Multiple linear lagged regression is used to extract the response of total Arctic FWC to a hypothetical step increase in the principal components of sea-level pressure. The results demonstrate that the FWC adjusts on a decadal timescale, consistent with the idea that wind-driven ocean dynamics and eddies determine the response of Arctic Ocean circulation and properties to a change in surface forcing, as suggested by idealized models and theory. Convolving the response of FWC to a change in sea-level pressure with historical sea-level pressure variations reveals that the recent observed increase in Arctic FWC is related to natural variations in sea-level pressure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kikukawa, Daisuke; Hori, Masaru; Honma, Koichiro
2006-11-15
Microwave excited plasma source operating at a low pressure of 1.5 Pa was newly developed. This plasma source was successfully applied to the formation of hydrogenated microcrystalline silicon films in a glass substrate with a mixture gas of silane (SiH{sub 4}), hydrogen (H{sub 2}), and xenon (Xe). It was found that the crystallinity of films was dramatically improved with decreasing pressure. The crystalline fraction was evaluated to be 82% at a substrate temperature of 400 deg. C, a mixture gas of SiH{sub 4}/H{sub 2}/Xe: 5/200/30 SCCM, and a total pressure of 1.5 Pa by Raman spectroscopy. The absolute density ofmore » hydrogen atoms and the behavior of higher radicals and molecules in the mixture gas were evaluated using vacuum ultraviolet absorption spectroscopy and quadrupole mass spectrometer, respectively. H atom densities were of the order of 10{sup 11} cm{sup -3}. The fraction of H atom density increased, while higher radicals and molecules decreased with decrease in the total pressure. The increase in H atom density and decrease in higher radicals and molecules improved the crystallinity of films in low pressures below 10 Pa.« less
Vortex Generators in a Streamline-Traced, External-Compression Supersonic Inlet
NASA Technical Reports Server (NTRS)
Baydar, Ezgihan; Lu, Frank K.; Slater, John W.; Trefny, Charles J.
2017-01-01
Vortex generators within a streamline-traced, external-compression supersonic inlet for Mach 1.66 were investigated to determine their ability to increase total pressure recovery and reduce total pressure distortion. The vortex generators studied were rectangular vanes arranged in counter-rotating and co-rotating arrays. The vane geometric factors of interest included height, length, spacing, angle-of-incidence, and positions upstream and downstream of the inlet terminal shock. The flow through the inlet was simulated numerically through the solution of the steady-state, Reynolds-averaged Navier-Stokes equations on multi-block, structured grids using the Wind-US flow solver. The vanes were simulated using a vortex generator model. The inlet performance was characterized by the inlet total pressure recovery and the radial and circumferential total pressure distortion indices at the engine face. Design of experiments and statistical analysis methods were applied to quantify the effect of the geometric factors of the vanes and search for optimal vane arrays. Co-rotating vane arrays with negative angles-of-incidence positioned on the supersonic diffuser were effective in sweeping low-momentum flow from the top toward the sides of the subsonic diffuser. This distributed the low-momentum flow more evenly about the circumference of the subsonic diffuser and reduced distortion. Co-rotating vane arrays with negative angles-of-incidence or counter-rotating vane arrays positioned downstream of the terminal shock were effective in mixing higher-momentum flow with lower-momentum flow to increase recovery and decrease distortion. A strategy of combining a co-rotating vane array on the supersonic diffuser with a counter-rotating vane array on the subsonic diffuser was effective in increasing recovery and reducing distortion.
Intrarenal hemodynamic changes following acute partial renal arterial occlusion.
DOT National Transportation Integrated Search
1965-10-01
Both an increase and a decrease in total renal vascular resistance, following a period of total renal artery occlusion, have been reported from this laboratory. The duration of the occlusive period and height of the perfusion pressure were found to p...
Issues of intergranular embrittlement of VVER-type nuclear reactors pressure vessel materials
NASA Astrophysics Data System (ADS)
Zabusov, O.
2016-04-01
In light of worldwide tendency to extension of service life of operating nuclear power plants - VVER-type in the first place - recently a special attention is concentrated on phenomena taking place in reactor pressure vessel materials that are able to lead to increased level of mechanical characteristics degradation (resistibility to brittle fracture) during long term of operation. Formerly the hardening mechanism of degradation (increase in the yield strength under influence of irradiation) mainly had been taken into consideration to assess pressure vessel service life limitations, but when extending the service life up to 60 years and more the non-hardening mechanism (intergranular embrittlement of the steels) must be taken into account as well. In this connection NRC “Kurchatov Institute” has initiated a number of works on investigations of this mechanism contribution to the total embrittlement of reactor pressure vessel steels. The main results of these investigations are described in this article. Results of grain boundary phosphorus concentration measurements in specimens made of first generation of VVER-type pressure vessels materials as well as VVER-1000 surveillance specimens are presented. An assessment of non-hardening mechanism contribution to the total ductile-to- brittle transition temperature shift is given.
NASA Technical Reports Server (NTRS)
Moore, C. S.; Collins, J. H. Jr
1932-01-01
The clearance distribution in a precombustion chamber cylinder head was varied so that for a constant compression ratio of 13.5 the spherical auxiliary chambers contained 20, 35, 50, and 70 per cent of the total clearance volume. Each chamber was connected to the cylinder by a single circular passage, flared at both ends, and of a cross-sectional area proportional to the chamber volume, thereby giving the same calculated air-flow velocity through each passage. Results of engine-performance tests are presented with variations of power, fuel consumption, explosion pressure, rate of pressure rise, ignition lag, heat loss to the cooling water, and motoring characteristics. For good performance the minimum auxiliary chamber volume, with the cylinder head design used, was 35 per cent of the total clearance volume; for larger volumes the performance improves but slightly. With the auxiliary chamber that contained 35 percent of the clearance volume there were obtained the lowest explosion pressures, medium rates of pressure rise, and slightly less than the maximum power. For all clearance distributions an increase in engine speed decreased the ignition lag in seconds and increased the rate of pressure rise.
Frequency of diarrhoea as a predictor of elevated blood pressure in children
Miranda, Juan Jaime; Davies, Alisha R.; Smith, George Davey; Smeeth, Liam; Cabrera, Lilia; Gilman, Robert H.; García, Héctor H.; Ortega, Ynes R.; Cama, Vitaliano A.
2009-01-01
Background Diarrhoeal illness is a major public health problem for children worldwide, particularly among developing countries, and is a proxy condition for severe dehydration. It has been hypothesized that severe dehydration in the first 6 months of life could be associated with increased blood pressure later in life. This study aimed to explore whether frequency of diarrhoea is associated with elevated blood pressure in children in a setting with a high incidence of diarrhoeal disease. Methods The present study is a cross-sectional study of blood pressure among children from a longitudinal child diarrhoeal disease cohort in Lima, Peru. From 2001 to 2006, daily diarrhoeal surveillance was made. Children were revisited in 2006 and blood pressure was measured. Diarrhoeal exposures were evaluated in terms of total number of diarrhoea days, number of episodes of diarrhoea, persistent diarrhoeal episodes and by the quartiles of daily incidence and episode incidence of diarrhoea. Results The overall incidence of diarrhoeal episodes at age under 1 year was 4.35 (95% confidence interval: 3.79-4.98) and under 5 years was 2.80 (95% confidence interval: 2.69-2.92). No association was observed between the total number of diarrhoeal days, diarrhoeal episodes or diarrhoeal incidence rates with childhood blood pressure. There was weak evidence that hospital admission due to severe dehydration in the first year of life showed a gradient towards an increase in both, systolic and diastolic blood pressure. Conclusion In the first study to date to examine the association in a setting with a high incidence of diarrhoeal disease, diarrhoeal frequency did not show an association with increased blood pressure. Our observations of elevated levels of blood pressure among those admitted into hospitals in the first year of life are in line with the original hypothesis of dehydration in early infancy and high blood pressure. However, the effect of episodes of severe dehydration on later blood pressure remains uncertain. PMID:19155783
Elevated central venous pressure: A consequence of exercise training-induced hypervolemia
NASA Technical Reports Server (NTRS)
Convertino, Victor A.; Mack, Gary W.; Nadel, Ethan R.
1990-01-01
Resting plasma volumes, and arterial and central venous pressures (CVP) were measured in 16 men before and after exercise training to determine if training-induced hypervolemia could be explained by a change in total vascular capacitance. In addition, resting levels of plasma vasopressin (AVP), atrial natriuretic peptide (ANP), aldosterone (ALD), and norepinephrine (NE) were measured before and after training. The same measurements of vacular volume, pressures, and plasma hormones were measured in 8 subjects who did not undergo exercise and acted as controls. The exercise training program consisted of 10 weeks of controlled cycle exercise for 30 min/d, 4 d/wk at 75 to 80 percent of maximal oxygen uptake (VO2max). A training effect was verified by a 20 percent increase in VO2max, a resting bradycardia, and a 370 ml (9 percent) increase in blood volume. Mean arterial blood pressure was unaltered by exercise training, but resting CVP increased. The percent change in blood volume from before to after training was linearly related to the percent change in CVP. As a consequence of elevations in both blood volume and CVP, the volume-to-pressure ratio was essentially unchanged following exercise training. Plasma AVP, ANP, ALD, and NE were unaltered. Results indicate that elevated CVP is a consequence of training-induced hypervolemia without alteration in total effective venous capacitance. This may represent a resetting of the pressure-volume stimulus-response relation for regulation of blood volume.
The morphology, physiology and nutritional quality of lettuce grown under hypobaria and hypoxia
NASA Astrophysics Data System (ADS)
Tang, Yongkang; Gao, Feng; Guo, Shuangsheng; Li, Fang
2015-07-01
The objectives of this research were to investigate the morphological, physiological and nutritional characteristics of lettuce plants (Lactuca sativa L. cv. Rome) under hypobaric and hypoxic conditions. Plants were grown under two levels of total pressures (101 and 30 kPa) and three levels of oxygen partial pressures (21, 6 and 2 kPa) for 20 days. Hypoxia (6 or 2 kPa) not only significantly inhibited the growth of lettuce plants by decreasing biomass, leaf area, root/shoot ratio, water content, the contents of minerals and organic compounds (vitamin C, crude protein and crude fat), but also destroyed the ultrastructure of mitochondria and chloroplast. The activities of catalase and total superoxide dismutase, the contents of glutathione and the total antioxidant capacity significantly decreased due to hypoxia. Hypobaria (30 kPa) did not markedly enhance the biomass, but it increased leaf area, root/shoot ratio and relative water content. Hypobaria also decreased the contents of total phenols, malondialdehyde and total carbohydrate and protected the ultrastructure of mitochondria and chloroplast under hypoxia. Furthermore, the activities of catalase and total superoxide dismutase, the contents of minerals and organic compounds markedly increased under hypobaria. This study demonstrates that hypobaria (30 kPa) does not increase the growth of lettuce plants, but it enhances plant's stress resistance and nutritional quality under hypoxia.
Instability of a shear layer between multicomponent fluids at supercritical pressure
NASA Astrophysics Data System (ADS)
Fu, Qing-fei; Zhang, Yun-xiao; Mo, Chao-jie; Yang, Li-jun
2018-04-01
The temporal instability of a thin shear layer lying between streams of two components of fluids has been studied. The effects of density profile of the layer on the instability behavior were mainly considered. The detailed density profile was obtained through Linear Gradient Theory. The eigenvalue problem was calculated, and the temporal instability curves were obtained for the thermodynamic parameters, e.g. pressure and temperature. The results show that, increase of pressure leads to the increase of the maximum growth rate. However, increasing pressure has opposite effects on the disturbances with small and large wave length. The increase of temperature causes the decrease of disturbance growth rate. The instability behavior of the shear layers was determined mainly by the interval between the inflections of the velocity and density profiles, and the maximum density gradient. The total effects, determined by coupling density stratification, and interval between the inflections of the velocity and density profiles, were quite distinct for different ranges of temperature and pressure.
Maher, Dermot P; Loyferman, Rusty; Yumul, Roya; Louy, Charles
2015-01-01
The implantation of total artificial hearts (TAH) via midline sternotomy for the treatment of severe biventricular cardiac dysfunction is associated with complex postoperative pain management. Ketamaine increases blood pressure by raising sympathetic outflow and cardiac output; however, ketamine is a direct vasodilator on isolated arterial tissues. In the setting of a TAH with a mechanically fixed cardiac output, a ketamine infusion for postoperative pain control has the potential to decrease blood pressure due to direct arterial vasodilation. We present the initial experience with a ketamine infusion in a patient with a TAH with minimal observed decreases in blood pressure and significantly improved postoperative pain.
Varmaghany, Saifali; Karimi Torshizi, Mohammad Amir; Rahimi, Shaban; Lotfollahian, Houshang; Hassanzadeh, Mohammad
2015-08-01
The effects of dietary garlic bulb were studied separately on hematological parameters, ascites incidence, and growth performance of an ascites susceptible broiler hybrid under both standard temperature conditions ( STC: ) and cold temperature conditions ( CTC: ). A total of 336 one-day-old male broiler chickens were allocated to 4 experimental groups with 4 replicates of 21 birds each under STC. In addition, the same grouping with another 336 birds was used for CTC. Under CTC, the birds were exposed to cold temperatures for induction of ascites. Experimental groups were defined by the inclusion of 0 (control), 5, 10 or 15 g/kg garlic bulbs in the diets under both STC and CTC. Growth performance, systolic blood pressure (as a measure of systemic arterial blood pressure), physiological and biochemical parameters, as well as ascites indices (right ventricle [ RV: ], total ventricle [ TV: ] weights, and RV/TV: ) were evaluated. Systolic blood pressure was determined using an indirect method with a sphygmomanometer, a pediatric cuff, and a Doppler device. The final body weight decreased quadratically (P = 0.003), with increasing garlic bulb levels in the diets under STC. The feed conversion ratio showed no significant differences among all groups under both STC and CTC. No significant differences were observed in total mortality and ascites-related mortality in all groups under STC, although total mortality (L: P = 0.01; Q: P = 0.001) and ascites-related mortality (L: P = 0.007; Q: P = 0.001) were significantly different among the diets under CTC. Under STC, the systolic blood pressure, packed cell volume, hemoglobin, RV, TV, and RV/TV did not vary significantly among the diets. However, red blood cell count and erythrocyte osmotic fragility decreased linearly (P < 0.005) with increasing garlic bulb levels in the diets under STC. Under CTC, the systolic blood pressure, packed cell volume, red blood cell count, and erythrocyte osmotic fragility decreased (P < 0.05) with increasing garlic levels. It is concluded that the inclusion of 5 g/kg garlic bulb in susceptible broiler chicken diets has a systemic anti-hypertensive effect and could decrease ascites incidence without impairing broiler chicken performance. © 2015 Poultry Science Association Inc.
Moore, F D
1976-01-01
Constraints on manpower are intrinsic in the establishment of standards of excellence. When such constraints are exerted by individual Boards, Societies, Colleges or Academies they should act to improve the quality of care; their weakness lies in their lack of control over non-members, or those who have failed to pass the examinations. Such manpower constraints become specific objectives or goals when the number of accredited specialists is specifically related to the size of the population served. Any such manpower planning must recognize the many uncertainties in the future of American medicine, and maintain wide elasticity in the planning process. Social and economic pressures render the consideration of specific manpower goals essential at this time. Data from the national surgical study (SOSSUS) make it possible to consider such goals. Manpower objectives for surgery or any other branch of medicine should be considered as a part of the total medical manpower outlook for the United States. Pressures to reduce the number of surgeons entering practice are notable at this time. These should be evaluated against other pressures to maintain or increase the number of hospital-based specialists in all fields as the total number of practitioners undergoes a major expansion over the next 25 years, and the pressure for specialty care is thereby increased. A reasonable balance between these two pressures would be a manpower goal for surgery that allowed a modest growth rate over the next 25-50 years. An example of such is the goal of limiting surgical practitioner growth to a 1% increase in the ratio to population, every 5 years. This would be in sharp contrast to the continuous explosive growth of numbers of surgeons, since World War II. PMID:952562
Assessing introduction risk using species’ rank-abundance distributions
Chan, Farrah T.; Bradie, Johanna; Briski, Elizabeta; Bailey, Sarah A.; Simard, Nathalie; MacIsaac, Hugh J.
2015-01-01
Mixed-species assemblages are often unintentionally introduced into new ecosystems. Analysing how assemblage structure varies during transport may provide insights into how introduction risk changes before propagules are released. Characterization of introduction risk is typically based on assessments of colonization pressure (CP, the number of species transported) and total propagule pressure (total PP, the total abundance of propagules released) associated with an invasion vector. Generally, invasion potential following introduction increases with greater CP or total PP. Here, we extend these assessments using rank-abundance distributions to examine how CP : total PP relationships change temporally in ballast water of ocean-going ships. Rank-abundance distributions and CP : total PP patterns varied widely between trans-Atlantic and trans-Pacific voyages, with the latter appearing to pose a much lower risk than the former. Responses also differed by taxonomic group, with invertebrates experiencing losses mainly in total PP, while diatoms and dinoflagellates sustained losses mainly in CP. In certain cases, open-ocean ballast water exchange appeared to increase introduction risk by uptake of new species or supplementation of existing ones. Our study demonstrates that rank-abundance distributions provide new insights into the utility of CP and PP in characterizing introduction risk. PMID:25473007
Habazettl, H; Stahn, Alexander; Nitsche, Andrea; Nordine, Michael; Pries, A R; Gunga, H-C; Opatz, O
2016-01-01
We hypothesized that lower body microvessels are particularly challenged during exposure to gravity and hypergravity leading to failure of resistance vessels to withstand excessive transmural pressure during hypergravitation and gravitation-dependent microvascular blood pooling. Using a short-arm human centrifuge (SAHC), 12 subjects were exposed to +1Gz, +2Gz and +1Gz, all at foot level, for 4 min each. Laser Doppler imaging and near-infrared spectroscopy were used to measure skin perfusion and tissue haemoglobin concentrations, respectively. Pretibial skin perfusion decreased by 19% during +1Gz and remained at this level during +2Gz. In the dilated area, skin perfusion increased by 24 and 35% during +1Gz and +2Gz, respectively. In the upper arm, oxygenated haemoglobin (Hb) decreased, while deoxy Hb increased with little change in total Hb. In the calf muscle, O2Hb and deoxy Hb increased, resulting in total Hb increase by 7.5 ± 1.4 and 26.6 ± 2.6 µmol/L at +1Gz and +2Gz, respectively. The dynamics of Hb increase suggests a fast and a slow component. Despite transmural pressures well beyond the upper myogenic control limit, intact lower body resistance vessels withstand these pressures up to +2Gz, suggesting that myogenic control may contribute only little to increased vascular resistance. The fast component of increasing total Hb indicates microvascular blood pooling contributing to soft tissue capacitance. Future research will have to address possible alterations of these acute adaptations to gravity after deconditioning by exposure to micro-g.
Harner, Christopher D; Mauro, Craig S; Lesniak, Bryson P; Romanowski, James R
2009-10-01
Tears of the posterior root of the medial meniscus are becoming increasingly recognized. They can cause rapidly progressive arthritis, yet their biomechanical effects are not understood. The goal of this study was to determine the effects of posterior root tears of the medial meniscus and their repairs on tibiofemoral joint contact pressure and kinematics. Nine fresh-frozen cadaver knees were used. An axial load of 1000 N was applied with a custom testing jig at each of four knee-flexion angles: 0 degrees , 30 degrees , 60 degrees , and 90 degrees . The knees were otherwise unconstrained. Four conditions were tested: (1) intact, (2) a posterior root tear of the medial meniscus, (3) a repaired posterior root tear, and (4) a total medial meniscectomy. Fuji pressure-sensitive film was used to record the contact pressure and area for each testing condition. Kinematic data were obtained by using a robotic arm to record the position of the knees for each loading condition. Three-dimensional knee kinematics were analyzed with custom programs with use of previously described transformations. The measured variables were axial rotation, varus angulation, lateral translation, and anterior translation. In the medial compartment, a posterior root tear of the medial meniscus caused a 25% increase in peak contact pressure compared with that found in the intact condition (p < 0.001). Repair restored the peak contact pressure to normal. No difference was detected between the peak contact pressure after the total medial meniscectomy and that associated with the root tear. The peak contact pressure in the lateral compartment after the total medial meniscectomy was up to 13% greater than that for all other conditions (p = 0.026). Significant increases in external rotation and lateral tibial translation, compared with the values in the intact knee, were observed in association with the posterior root tear (2.98 degrees and 0.84 mm, respectively) and the meniscectomy (4.45 degrees and 0.80 mm, respectively), and these increases were corrected by the repair. This study demonstrated significant changes in contact pressure and knee joint kinematics due to a posterior root tear of the medial meniscus. Root repair was successful in restoring joint biomechanics to within normal conditions.
Non-pharmacological treatment of hypertension.
Silverberg, D S
1990-09-01
Weight reduction, alcohol restriction, mild salt restriction, eating a vegetarian diet and increasing aerobic exercise will generally lower the blood pressure in patients with essential hypertension. Eating a diet rich in potassium and reducing caffeine intake may also be helpful in reducing the pressure, but increasing the fiber or calcium intake will generally be ineffective. Reducing fat intake from the usual 40% of total calories to 25-30% may reduce hypertension directly or by weight reduction. Smoking, when combined with excessive caffeine or alcohol intake may have an additive effect on blood pressure. Monotherapy with such behavioral techniques as self-monitoring of blood pressure, biofeedback, meditation, yoga, progressive muscular relaxation or cognitive therapy may reduce the blood pressure to a variable degree, and combinations of these treatments may be even more successful.
Piezoelectrically-induced trap-depth reduction model of elastico-mechanoluminescent materials
NASA Astrophysics Data System (ADS)
Chandra, B. P.; Chandra, V. K.; Jha, Piyush
2015-03-01
Considering the detrapping of charge carriers due to reduction in trap-depth caused by piezoelectric field produced by applied pressure, an expression is derived for the detrapping rate of electrons. Then, an expression is obtained for the rate of generation of excited ions produced during capture of detrapped electrons by Eu3+ ions in persistent luminescent materials or by the energy released during electron-hole recombination in ZnS:Mn crystals. Finally, an expression is explored for the elastico-mechanoluminescence (EML) intensity, which is able to explain satisfactorily the characteristics of EML for the application of static pressure as well as for impact pressure. The total number of detrapped electrons and the total EML intensity are found to increase linearly with the electrostatic energy of the crystals in piezoelectric field. It is shown that the EML intensity should increase with the EML efficiency, number of crystallites (volume of sample), concentration of local piezoelectric regions in crystallites, piezoelectric constant of local piezoelectric regions, average length of the local piezoelectric regions, total number of electron traps, pressing rate, and applied pressure, and it should be higher for the materials having low value of threshold pressure and low value of trap-depth in unstressed condition. On the basis of the piezoelectrically-induced trap-depth reduction model of EML reported in the present investigation novel intense elastico mechanoluminescent materials having repetitive EML with undiminished intensity for successive loadings can be tailored which may find applications in sensing, imaging, lighting, colored displays, and other mechano-optical devices.
Xu, Baojun; Chang, Sam K C
2008-09-01
The effects of soaking, boiling and steaming processes on the total phenolic components and antioxidant activity in commonly consumed cool season food legumes (CSFL's), including green pea, yellow pea, chickpea and lentil were investigated. As compared to original unprocessed legumes, all processing steps caused significant (p<0.05) decreases in total phenolic content (TPC), DPPH free radical scavenging activity (DPPH) in all tested CSFL's. All soaking and atmospheric boiling treatments caused significant (p<0.05) decreases in oxygen radical absorbing capacity (ORAC). However, pressure boiling and pressure steaming caused significant (p<0.05) increases in ORAC values. Steaming treatments resulted in a greater retention of TPC, DPPH, and ORAC values in all tested CSFL's as compared to boiling treatments. To obtain cooked legumes with similar palatability and firmness, pressure boiling shortened processing time as compared to atmospheric boiling, resulted in insignificant differences in TPC, DPPH for green and yellow pea. However, TPC and DPPH in cooked lentils differed significantly between atmospheric and pressure boiling. As compared to atmospheric processes, pressure processes significantly increased ORAC values in both boiled and steamed CSFL's. Greater TPC, DPPH and ORAC values were detected in boiling water than that in soaking and steaming water. Boiling also caused more solid loss than steaming. Steam processing exhibited several advantages in retaining the integrity of the legume appearance and texture of the cooked product, shortening process time, and greater retention of antioxidant components and activities. Copyright © 2008 Elsevier Ltd. All rights reserved.
Karanikolić, Aleksandar; Karanikolić, Vesna; Djordjević, Lidija; Pešić, Ivan
2016-01-01
There is very little literature data on the correlation between the seasons, temperature and atmospheric pressure, and pathogenesis of acute appendicitis (AA). The aim of this research is to investigate the association between the seasons, changes in atmospheric temperature and pressure, and patients’ age and severity of the clinical form of AA in the city of Niš This study included 395 patients diagnosed with AA, who, during the two-year period, from July 1st 2011 to June 30th 2013, were hospitalized and operated on at the Department of General Surgery, Clinical Center in Niš, Serbia. The increased average daily values of barometric pressure by 1 millibar on the day when the event took place was associated (p < 0.05) with the decrease of total risk of the occurrence of appendicitis by 2.2% (0.2–4.1%). In all observed patients, each increase of the mean daily temperature by 1°C three days before the event took place (Lag 3) was associated (p < 0.05) with the increase of total risk of the occurrence of appendicitis by 1.3% (0.1–2.5%). According to the results of this research, we can conclude that patients’ sex, age and severity of the clinical form of AA are not in connection with the seasons, while there are certain connections between appendicitis occurrence and atmospheric temperature and pressure.
Osmotic effects of polyethylene glycol.
Schiller, L R; Emmett, M; Santa Ana, C A; Fordtran, J S
1988-04-01
Polyethylene glycol (PEG) has been used to increase the osmotic pressure of fluids used to cleanse the gastrointestinal tract. However, little is known about its osmotic activity. To investigate this activity systematically, solutions of PEG of differing molecular weights were made and subjected to measurement of osmolality by both freezing point depression and vapor pressure osmometry. Measured osmolality was increasingly greater than predicted from average molecular weight as PEG concentration increased. Measurement of sodium activity in NaCl/PEG solutions by means of an ion-selective electrode suggested that the higher than expected osmolality could be due in part to interactions that, in effect, sequestered water from the solution. Osmolality was consistently greater by freezing point osmometry than by vapor pressure osmometry. To determine which osmometry method reflected biologically relevant osmolality, normal subjects underwent steady-state total gut perfusion with an electrolyte solution containing 105 g/L of PEG 3350. This produced rectal effluent that was hypertonic by freezing point osmometry but isotonic by vapor pressure osmometry. Assuming that luminal fluid reaches osmotic equilibrium with plasma during total gut perfusion, this result suggests that the vapor pressure osmometer accurately reflects the biologically relevant osmolality of intestinal contents. We conclude that PEG exerts more of an osmotic effect than would be predicted from its molecular weight. This phenomenon may reflect interactions between PEG and water molecules that alter the physical chemistry of the solution and sequester water from the solution.
Berglund, B; Brevinge, H; Akerlund, S; Kock, N G
1992-01-01
When bladder substitution is required, a low pressure receptacle and an antireflux valve with low resistance to flow is essential for preservation of the upper urinary tract. The aim of this study was to evaluate whether these criteria are attained in the continent ileal reservoir used for urinary diversion. The investigations were performed in six patients more than one year after supravesical urinary diversion via a continent ileal reservoir. The pressure was recorded simultaneously both in the afferent loop and in the reservoir during filling of the reservoir. There was a slow parallel increase in the basal pressure in the reservoir and the afferent loop. Pressure waves appeared sometimes simultaneously and sometimes in only one compartment at a time. Only during short periods of time did the pressure exceed 25 cm of water. The frequency of pressure waves increased with increased filling of the reservoir. The "total pressure" was larger in the reservoir than in the afferent loop. It is the antireflux valve which prevents pressure rises in the reservoir from being conveyed to the upper urinary tract. The resistance to urinary flow was moderate.
Inter-arm blood pressure differences in pregnant women.
Poon, L C Y; Kametas, N; Strobl, I; Pachoumi, C; Nicolaides, K H
2008-08-01
To determine the prevalence of blood pressure inter-arm difference (IAD) in early pregnancy and to investigate its possible association with maternal characteristics. A cross-sectional observational study. Routine antenatal visit in a university hospital. A total of 5435 pregnant women at 11-14 weeks of gestation. Blood pressure was taken from both arms simultaneously with a validated automated device. The presence of inter-arm blood pressure difference of 10 mmHg or more. The IAD in systolic and diastolic blood pressure was 10 mmHg or more in 8.3 and 2.3% of the women, respectively. Systolic IAD was found to be significantly related to systolic blood pressure and pulse pressure, and diastolic IAD was found to be significantly related to maternal age, diastolic blood pressure and pulse pressure. The systolic and diastolic IAD were higher in the hypertensive group compared with the normotensive group and absolute IAD increased with increasing blood pressure. About 31.0 and 23.9% of cases of hypertension would have been underreported if the left arm and the right arm were used, respectively, in measuring the blood pressure. There is a blood pressure IAD in a significant proportion of the pregnant population, and its prevalence increases with increasing blood pressure. By measuring blood pressure only on one arm, there is a one in three chance of underreporting hypertension. Therefore, it would be prudent that during the booking visit blood pressure should be taken in both arms and thus provide guidance for subsequent blood pressure measurements during the course of pregnancy.
Biometric Screening and Future Employer Medical Costs: Is It Worth It to Know?
Vanichkachorn, Greg; Marchese, Maya; Roy, Brad; Opel, Gordon
2017-12-01
To study the relationship between a biometric wellness data and future/actual medical costs. A relationship between total cholesterol to high density lipoprotein ratio, blood pressure, and blood glucose and medical costs, based on analysis of claims data, was explored in 1834 employees that had both wellness program biometric and claims data in 2016. Increased total cholesterol to HDL ratio is strongly associated with increased average costs (P < 0.01). Similarly, an increased glucose level is strongly associated with increased average costs (P = 0.001). There was no evidence of a relationship between elevated blood pressure and higher costs. By investing in an employer-sponsored biometric screening of full cholesterol and glucose profiles, medium-sized employers can identify high-risk employees who are expected to incur significantly higher healthcare costs, as compared with low-risk level employees, and improve treatment outcomes.
Enhanced Performance of Streamline-Traced External-Compression Supersonic Inlets
NASA Technical Reports Server (NTRS)
Slater, John W.
2015-01-01
A computational design study was conducted to enhance the aerodynamic performance of streamline-traced, external-compression inlets for Mach 1.6. The current study explored a new parent flowfield for the streamline tracing and several variations of inlet design factors, including the axial displacement and angle of the subsonic cowl lip, the vertical placement of the engine axis, and the use of porous bleed in the subsonic diffuser. The performance was enhanced over that of an earlier streamline-traced inlet such as to increase the total pressure recovery and reduce total pressure distortion
Lipin, Bruce R.
1993-01-01
This paper explores the hypothesis that chromite seams in the Stillwater Complex formed in response to periodic increases in total pressure in the chamber. Total pressure increased because of the positive δV of nucleation of CO2 bubbles in the melt and their subsequent rise through the magma chamber, during which the bubbles increased in volume by a factor of 4–6. By analogy with the pressure changes in the summit chambers of Kilauea and Krafla volcanoes, the maximum variation was 0⋅2–0⋅25 kbar, or 5–10% of the total pressure in the Stillwater chamber. An evaluation of the likelihood of fountaining and mixing of a new, primitive liquid that entered the chamber with the somewhat more evolved liquid already in the chamber is based upon calculations using observed and inferred velocities and flow rates of basaltic magmas moving through volcanic fissures. The calculations indicate that hot, dense magma would have oozed, rather than fountained into the chamber, and early mixing of the new and residual magmas that could have resulted in chromite crystallizing alone did not take place.Mixing was an important process in the Stillwater magma chamber, however. After the new magma in the chamber underwent ˜5% fractional crystallization, its composition, temperature, and density approached those of the overlying liquid in the chamber and the liquids then mixed. If this process occurred many times over the course of the development of the Ultramafic series, a thick column of magma with orthopyroxene on its liquidus would have been the result. Thus, the sequence of multiple injections, fractionation, and mixing with previously fractionated magma could have been the mechanism that produced the thick bronzite cumulate layer (the Bronzitite zone) above the cyclic units.
Plantar loading during cutting while wearing a rigid carbon fiber insert.
Queen, Robin M; Abbey, Alicia N; Verma, Ravi; Butler, Robert J; Nunley, James A
2014-01-01
Stress fractures are one of the most common injuries in sports, accounting for approximately 10% of all overuse injuries. Treatment of fifth metatarsal stress fractures involves both surgical and nonsurgical interventions. Fifth metatarsal stress fractures are difficult to treat because of the risks of delayed union, nonunion, and recurrent injuries. Most of these injuries occur during agility tasks, such as those performed in soccer, basketball, and lacrosse. To examine the effect of a rigid carbon graphite footplate on plantar loading during 2 agility tasks. Crossover study. Laboratory. A total of 19 recreational male athletes with no history of lower extremity injury in the past 6 months and no previous metatarsal stress fractures were tested. Seven 45° side-cut and crossover-cut tasks were completed in a shoe with or without a full-length rigid carbon plate. Testing order between the shoe conditions and the 2 cutting tasks was randomized. Plantar-loading data were recorded using instrumented insoles. Peak pressure, maximum force, force-time integral, and contact area beneath the total foot, the medial and lateral midfoot, and the medial, middle, and lateral forefoot were analyzed. A series of paired t tests was used to examine differences between the footwear conditions (carbon graphite footplate, shod) for both cutting tasks independently (α = .05). During the side-cut task, the footplate increased total foot and lateral midfoot peak pressures while decreasing contact area and lateral midfoot force-time integral. During the crossover-cut task, the footplate increased total foot and lateral midfoot peak pressure and lateral forefoot force-time integral while decreasing total and lateral forefoot contact area. Although a rigid carbon graphite footplate altered some aspects of the plantar-pressure profile during cutting in uninjured participants, it was ineffective in reducing plantar loading beneath the fifth metatarsal.
Aerothermal tests of quilted dome models on a flat plate at a Mach number of 6.5
NASA Technical Reports Server (NTRS)
Glass, Christopher E.; Hunt, L. Roane
1988-01-01
Aerothermal tests were conducted in the NASA Langley 8 Foot High Temperature Tunnel (8'HTT) at a Mach number of 6.5 on simulated arrays of thermally bowed metallic thermal protection system (TPS) tiles at an angle of attack of 5 deg. Detailed surface pressures and heating rates were obtained for arrays aligned with the flow and skewed 45 deg diagonally to the flow with nominal bowed heights of 0.1, 0.2, and 0.4 inch submerged in both laminar and turbulent boundary layers. Aerothermal tests were made at a nominal total temperature of 3300 R, a total pressure of 400 psia, a total enthalpy of 950 Btu/lbm, a dynamic pressure of 2.7 psi, and a unit Reynolds number of 400,000 per foot. The experimental results form a data base that can be used to help protect aerothermal load increases from bowed arrays of TPS tiles.
Biomechanics of Hyperflexion and Kneeling before and after Total Knee Arthroplasty
2014-01-01
The capacity to perform certain activities is frequently compromised after total knee arthroplasty (TKA) due to a functional decline resulting from decreased range of motion and a diminished ability to kneel. In this manuscript, the current biomechanical understanding of hyperflexion and kneeling before and after TKA will be discussed. Patellofemoral and tibiofemoral joint contact area, contact pressure, and kinematics were evaluated in cadaveric studies using a Tekscan pressure measuring system and Microscribe. Testing was performed on intact knees and following cruciate retaining and posterior stabilized TKA at knee flexion angles of 90°, 105°, 120°, and 135°. Three loading conditions were used to simulate squatting, double stance kneeling, and single stance kneeling. Following TKA with double stance kneeling, patellofemoral contact areas did not increase significantly at high knee flexion angle (135°). Kneeling resulted in tibial posterior translation and external rotation at all flexion angles. Moving from double to single stance kneeling tended to increase pressures in the cruciate retaining group, but decreased pressures in the posterior stabilized group. The cruciate retaining group had significantly larger contact areas than the posterior stabilized group, although no significant differences in pressures were observed comparing the two TKA designs (p < 0.05). If greater than 120° of postoperative knee range of motion can be achieved following TKA, then kneeling may be performed with less risk in the patellofemoral joint than was previously believed to be the case. However, kneeling may increase the likelihood of damage to cartilage and menisci in intact knees and after TKA increases in tibiofemoral contact area and pressures may lead to polyethyelene wear if performed on a chronic, repetitive basis. PMID:24900891
Biomechanics of hyperflexion and kneeling before and after total knee arthroplasty.
Lee, Thay Q
2014-06-01
The capacity to perform certain activities is frequently compromised after total knee arthroplasty (TKA) due to a functional decline resulting from decreased range of motion and a diminished ability to kneel. In this manuscript, the current biomechanical understanding of hyperflexion and kneeling before and after TKA will be discussed. Patellofemoral and tibiofemoral joint contact area, contact pressure, and kinematics were evaluated in cadaveric studies using a Tekscan pressure measuring system and Microscribe. Testing was performed on intact knees and following cruciate retaining and posterior stabilized TKA at knee flexion angles of 90°, 105°, 120°, and 135°. Three loading conditions were used to simulate squatting, double stance kneeling, and single stance kneeling. Following TKA with double stance kneeling, patellofemoral contact areas did not increase significantly at high knee flexion angle (135°). Kneeling resulted in tibial posterior translation and external rotation at all flexion angles. Moving from double to single stance kneeling tended to increase pressures in the cruciate retaining group, but decreased pressures in the posterior stabilized group. The cruciate retaining group had significantly larger contact areas than the posterior stabilized group, although no significant differences in pressures were observed comparing the two TKA designs (p < 0.05). If greater than 120° of postoperative knee range of motion can be achieved following TKA, then kneeling may be performed with less risk in the patellofemoral joint than was previously believed to be the case. However, kneeling may increase the likelihood of damage to cartilage and menisci in intact knees and after TKA increases in tibiofemoral contact area and pressures may lead to polyethyelene wear if performed on a chronic, repetitive basis.
Effects of hypobaria and hypoxia on seed germination of six plant species
NASA Astrophysics Data System (ADS)
Tang, Yongkang; Gao, Feng; Guo, Shuangsheng; Li, Fang
2014-10-01
Hypobaria (low pressure) is typically associated with hypoxia (low oxygen partial pressure). There are several advantages of growing higher plants under hypobaria in the moon or mars habitat. The objectives of this research were to investigate the seed germination of six plant species under hypobaric and ambient total pressure conditions. Seeds were sown and germinated under three levels of total atmospheric pressure (101, 30 and 10 kPa) and three levels of oxygen partial pressures (21, 6 and 2 kPa) in an 8-day study. Hypoxia (6 or 2 kPa) significantly inhibited all seed germination under three levels of total atmospheric pressure by increasing the electrical conductivity and the optical density, decreasing the seed germination percentage and seed dehydrogenase activity and inhibiting the growth of the shoots and roots. Hypobaria (30 or 10 kPa) markedly improved seed germination and root growth by enhancing the oxygen diffusion rate under hypoxic conditions (6 or 2 kPa). The seeds of three dicot plants (lettuce, Chinese cabbage and cucumber) were more sensitive to hypoxia caused by hypobaria than were those of three monocot plants (maize, wheat and rice); lettuce and cucumber seeds had the highest sensitivity, whereas rice seeds had the lowest sensitivity. This research demonstrates that six experimental seeds can germinate normally under hypobaria (30 kPa), but the oxygen partial pressure should not be less than 6 kPa.
Nongnuch, Arkom; Campbell, Neil; Stern, Edward; El-Kateb, Sally; Fuentes, Laura; Davenport, Andrew
2015-02-01
Recently, intradialytic hypertension was reported to be associated with increased mortality for hemodialysis patients. To determine whether volume status plays a role in dialysis-associated hypertension, we prospectively audited 531 patients that had volume assessments measured by multiple-frequency bioelectrical impedance during their midweek dialysis session. Mean pre- and postdialysis weights were 73.2 vs 71.7 kg, and systolic blood pressures (SBPs) 140.5 vs. 130.3 mm Hg, respectively. Patients were divided into groups based on a fall in SBP of 20 mm Hg or more (32%), an increased SBP of 10 mm Hg or more (18%), and a stable group (50%). There were no differences in patient demographics, dialysis prescriptions, predialysis weight, total body (TBW), and extracellular (ECW) and intracellular water (ICW). However, the change in weight was significantly less in the increased blood pressure group (1.01 kg vs. stable 1.65, and 1.7 hypotensive). The ratio of ECW to TBW was significantly higher in the increased blood pressure group, particularly post dialysis (39.1 vs. stable 38.7% and fall in blood pressure group 38.7%). ECW overhydration was significantly greater in the increased blood pressure group post dialysis (0.7 (0.17 to 1.1) vs. stable 0.39 (-0.2 to 0.95) and fall in blood pressure group 0.38 (-0.19 to 0.86) liter). We found that patients who had increased blood pressure post dialysis had greater hydration status, particularly ECW. Thus, patients who increase their blood pressure post dialysis should have review of target weight, consideration of lowering the post-dialysis weight, and may benefit from increasing dialysis session time or frequency.
Surface modification of Monel K-500 as a means of reducing friction and wear in high-pressure oxygen
NASA Technical Reports Server (NTRS)
Gunaji, Mohan; Stoltzfus, Joel M.; Schoenman, Leonard; Kazaroff, John
1989-01-01
A study is conducted of the tribological characteristics of Monel K-500 during rubbing in a high pressure oxygen atmosphere, upon surface treatment by ion-implanted oxygen, chromium, lead, and silver, as well as electrolyzed chromium and an electroless nickel/SiC composite. The electrolyzed chromium dramatically increased total sample wear, while other surface treatments affected sample wear only moderately. Although the ion-implant treatments reduced the average coefficient of friction at low contact pressure, higher contact pressures eliminated this improvement.
Solar wind control of magnetospheric pressure (CDAW 6)
NASA Technical Reports Server (NTRS)
Fairfield, D. H.
1985-01-01
The CDAW 6 data base is used to compare solar wind and magnetospheric pressures. The flaring angle of the tail magnetopause is determined by assuming that the component of solar wind pressure normal to the tail boundary is equal to the total pressure within the tail. Results indicate an increase in the tail flaring angle from 18 deg to 32 deg prior to the 1055 substorm onset and a decrease to 25 deg after the onset. This behavior supports the concept of tail energy storage before the substorm and subsequent release after the onset.
Elevated central venous pressure: a consequence of exercise training-induced hypervolemia?
NASA Technical Reports Server (NTRS)
Convertino, V. A.; Mack, G. W.; Nadel, E. R.
1991-01-01
Resting blood volumes and arterial and central venous pressures (CVP) were measured in 14 men before and after exercise training to determine whether training-induced hypervolemia is accompanied by a change in total vascular capacitance. In addition, resting levels of plasma arginine vasopressin (AVP), atrial natriuretic peptide (ANP), aldosterone (Ald), and norepinephrine (NE) were measured. The same measurements were conducted in seven subjects who did not undergo exercise and acted as controls. Exercise training consisted of 10 wk of controlled cycle exercise for 30 min/day, 4 days/wk at 75-80% of maximal O2 uptake (VO2max). A training effect was verified by a 20% increase in VO2max, a resting bradycardia, and a 9% increase in blood volume. Mean arterial blood pressure was unaltered by exercise training, but resting CVP increased by 16% (P less than 0.05). The percent change in blood volume from before to after training was linearly related to the percent change in CVP (r = 0.903, P less than 0.05). As a consequence of elevations in both blood volume and CVP, the volume-to-pressure ratio was unchanged after exercise training. Plasma AVP, ANP, Ald, and NE were unaltered. Our results indicate that elevated CVP is a consequence of training-induced hypervolemia without alteration in total effective venous capacitance.
NASA Astrophysics Data System (ADS)
Singla, Rohit; Chowdhury, Kanchan
2017-02-01
Specific power consumed in a Linde double column air separation unit (ASU) increases as the quantity of oxygen produced at a given purity is decreased due to the changes of system requirement or market demand. As the plant operates in part load condition, the specific power consumption (SPC) increases as the total power consumption remains the same. In order to mitigate the increase of SPC at lower oxygen production, the operating pressure of high pressure column (HPC) can be lowered by extending the low pressure column (LPC) by a few trays and adding a second reboiler. As the duty of second reboiler in LPC is increased, the recovery of oxygen decreases with a lowering of the HPC pressure. This results in mitigation of the increase of SPC of the plant. A Medium pressure ASU with dual reboiler that produces pressurised gaseous and liquid products of oxygen and nitrogen is simulated in Aspen Hysys 8.6®, a commercial process simulator to determine SPC at varying oxygen production. The effects of reduced pressure of air feed into the cold box on the size of heat exchangers (HX) are analysed. Operation strategy to obtain various oxygen production rates at varying demand is also proposed.
NASA Technical Reports Server (NTRS)
Felder, James L.; Tong, Michael T.; Chu, Julio
2012-01-01
In a previous study by the authors it was shown that the N3-X, a 300 passenger hybrid wing body (HWB) aircraft with a turboelectric distributed propulsion (TeDP) system, was able to meet the NASA Subsonic Fixed Wing (SFW) project goal for N+3 generation aircraft of at least a 60% reduction in total energy consumption as compared to the best in class current generation aircraft. This previous study combined technology assumptions that represented the highest anticipated values that could be matured to technology readiness level (TRL) 4-6 by 2030. This paper presents the results of a sensitivity analysis of the total mission energy consumption to reductions in each key technology assumption. Of the parameters examined, the mission total energy consumption was most sensitive to changes to total pressure loss in the propulsor inlet. The baseline inlet internal pressure loss is assumed to be an optimistic 0.5%. An inlet pressure loss of 3% increases the total energy consumption 9%. However changes to reduce inlet pressure loss can result in additional distortion to the fan which can reduce fan efficiency or vice versa. It is very important that the inlet and fan be analyzed and optimized as a single unit. The turboshaft hot section is assumed to be made of ceramic matrix composite (CMC) with a 3000 F maximum material temperature. Reducing the maximum material temperature to 2700 F increases the mission energy consumption by only 1.5%. Thus achieving a 3000 F temperature in CMCs is important but not central to achieving the energy consumption objective of the N3-X/TeDP. A key parameter in the efficiency of superconducting motors and generators is the size of the superconducting filaments in the stator. The size of the superconducting filaments in the baseline model is assumed to be 10 microns. A 40 micron filament, which represents current technology, results in a 200% increase in AC losses in the motor and generator stators. This analysis shows that for a system with 40 micron filaments the higher stator losses plus the added weight and power of larger cryocoolers results in a 4% increase in mission energy consumption. If liquid hydrogen is used to cool the superconductors the 40 micron fibers results in a 200% increase in hydrogen required for cooling. Each pound of hydrogen used as fuel displaces 3 pounds of jet fuel. For the N3-X on the reference mission the additional hydrogen due to the increase stator losses reduces the total fuel weight 10%. The lighter fuel load and attendant vehicle resizing reduces the total energy consumption more than the higher stator losses increase it. As a result with hydrogen cooling there is a slight reduction in mission energy consumption with increasing stator losses. This counter intuitive result highlights the need to consider the full system impact of changes rather than just at the component or subsystem level.
Honnegowda, Thittamaranahalli Muguregowda; Padmanabha Udupa, Echalasara Govindarama; Rao, Pragna; Kumar, Pramod; Singh, Rekha
2016-01-01
BACKGROUND Thermal injury is associated with several biochemical and histopathological alteration in tissue. Analysis of these objective parameters in research and clinical field are common to determine healing rate of burn wound. Negative pressure wound therapy has been achieved wide success in treating chronic wounds. This study determines superficial burn wound healing with intermittent negative pressure wound therapy under limited access and conventional dressings METHODS A total 50 patients were randomised into two equal groups: limited access and conventional dressing groups. Selective biochemical parameters such as hydroxyproline, hexosamine, total protein, and antioxidants, malondialdhyde (MDA), wound surface pH, matrix metalloproteinase-2 (MMP-2), and nitric oxide (NO) were measured in the granulation tissue. Histopathologically, necrotic tissue, amount of inflammatory infiltrate, angiogenesis and extracellular matrix deposition (ECM) were studied to determine wound healing under intermittent negative pressure. RESULTS Patients treated with limited access have shown significant increase in the mean hydroxyproline, hexosamine, total protein, reduced glutathione (GSH), glutathione peroxidase (GPx), and decrease in MDA, MMP-2, wound surface pH, and NO. Histopathologic study showed that there was a significant difference after 10 days of treatment between limited access vs conventional dressing group, Median (Q1, Q3)=3 (2, 4.25) vs 2 (1.75, 4). CONCLUSION Limited access was shown to exert its beneficial effects on wound healing by increasing ground substance, antioxidants and reducing MMP-2 activity, MDA, NO and providing optimal pH, decreasing necrotic tissue, amount of inflammatory infiltrate, increasing ECM deposition and angiogenesis. PMID:27853690
Impact of optimised cooking on the antioxidant activity in edible mushrooms.
Ng, Zhi Xiang; Tan, Wan Chein
2017-11-01
This study aimed to investigate the effect of four cooking methods with different durations on the in vitro antioxidant activities of five edible mushrooms, namely Agaricus bisporus , Flammulina velutipes , Lentinula edodes , Pleurotus ostreatus and Pleurotus eryngii. Among the raw samples, A. bisporus showed the highest total antioxidant activity (reducing power and radical scavenging), total flavonoid, ascorbic acid and water soluble phenolic contents. Short-duration steam cooking (3 min) increased the total flavonoid and ascorbic acid while prolonged pressure cooking (15 min) reduced the water soluble phenolic content in the mushrooms. The retention of antioxidant value in the mushrooms varied with the variety of mushroom after the cooking process. The cooking duration significantly affected the ascorbic acid in the mushrooms regardless of cooking method. To achieve the best antioxidant values, steam cooking was preferred for F. velutipes (1.5 min), P. ostreatus (4.5 min) and L. edodes (4.5 min) while microwave cooking for 1.5 min was a better choice for A. bisporus . Pressure cooked P. eryngii showed the best overall antioxidant value among the cooked samples. Optimised cooking method including pressure cooking could increase the antioxidant values in the edible mushrooms.
Effects of front-loading and stagger angle on endwall losses of high lift low pressure turbine vanes
NASA Astrophysics Data System (ADS)
Lyall, M. Eric
Past efforts to reduce the airfoil count in low pressure turbines have produced high lift profiles with unacceptably high endwall loss. The purpose of the current work is to suggest alternative approaches for reducing endwall losses. The effects of the fluid mechanics and high lift profile geometry are considered. Mixing effects of the mean flow and turbulence fields are decoupled to show that mean flow shear in the endwall wake is negligible compared to turbulent shear, indicating that turbulence dissipation is the primary cause of total pressure loss. The mean endwall flow field does influence total pressure loss by causing excessive wake growth and perhaps outright separation on the suction surface. For equivalent stagger angles, a front-loaded high lift profile will produce less endwall loss than one aft-loaded, primarily by suppressing suction surface flow separation. Increasing the stagger setting, however, increases the endwall loss due to the static pressure field generating a stronger blockage relative to the incoming endwall boundary layer flow and causing a larger mass of fluid to become entrained in the horseshoe vortex. In short, front-loading the pressure distribution suppresses suction surface separation whereas limiting the stagger angle suppresses inlet boundary layer separation. Results of this work suggest that a front-loaded low stagger profile be used at the endwall to reduce the endwall loss.
Sewage sludge solubilization by high-pressure homogenization.
Zhang, Yuxuan; Zhang, Panyue; Guo, Jianbin; Ma, Weifang; Fang, Wei; Ma, Boqiang; Xu, Xiangzhe
2013-01-01
The behavior of sludge solubilization using high-pressure homogenization (HPH) treatment was examined by investigating the sludge solid reduction and organics solubilization. The sludge volatile suspended solids (VSS) decreased from 10.58 to 6.67 g/L for the sludge sample with a total solids content (TS) of 1.49% after HPH treatment at a homogenization pressure of 80 MPa with four homogenization cycles; total suspended solids (TSS) correspondingly decreased from 14.26 to 9.91 g/L. About 86.15% of the TSS reduction was attributed to the VSS reduction. The increase of homogenization pressure from 20 to 80 MPa or homogenization cycle number from 1 to 4 was favorable to the sludge organics solubilization, and the protein and polysaccharide solubilization linearly increased with the soluble chemical oxygen demand (SCOD) solubilization. More proteins were solubilized than polysaccharides. The linear relationship between SCOD solubilization and VSS reduction had no significant change under different homogenization pressures, homogenization cycles and sludge solid contents. The SCOD of 1.65 g/L was solubilized for the VSS reduction of 1.00 g/L for the three experimental sludge samples with a TS of 1.00, 1.49 and 2.48% under all HPH operating conditions. The energy efficiency results showed that the HPH treatment at a homogenization pressure of 30 MPa with a single homogenization cycle for the sludge sample with a TS of 2.48% was the most energy efficient.
Experimental Investigation of Oscillatory Flow Pressure and Pressure Drop Through Complex Geometries
NASA Technical Reports Server (NTRS)
Ibrahim, Mounir B.; Wang, Meng; Gedeon, David
2005-01-01
A series of experiments have been performed to investigate the oscillatory flow pressure and pressure drop through complex geometries. These experiments were conducted at the CSU-SLRE facility which is a horizontally opposed, two-piston, single-acting engine with a split crankshaft driving mechanism. Flow through a rectangular duct, with no insert (obstruction), was studied first. Then four different inserts were examined: Abrupt, Manifold, Diverging Short and Diverging Long. The inserts were mounted in the center of the rectangular duct to represent different type of geometries that could be encountered in Stirling machines. The pressure and pressure drop of the oscillating flow was studied for: 1) different inserts, 2) different phase angle between the two pistons of the engine (zero, 90 lead, 180, and 90 lag), and 3) for different piston frequencies (5, 10, 15, and 20 Hz). It was found that the pressure drop of the oscillatory flow increases with increasing Reynolds number. The pressure drop was shown to be mainly due to the gas inertia for the case of oscillatory flow through a rectangular duct with no insert. On the other hand, for the cases with different inserts into the rectangular duct, the pressure drop has three sources: inertia, friction, and local losses. The friction pressure drop is only a small fraction of the total pressure drop. It was also shown that the dimensionless pressure drop decreases with increasing kinetic Reynolds number.
Kharche, Sanjay R.; So, Aaron; Salerno, Fabio; Lee, Ting-Yim; Ellis, Chris; Goldman, Daniel; McIntyre, Christopher W.
2018-01-01
Dialysis prolongs life but augments cardiovascular mortality. Imaging data suggests that dialysis increases myocardial blood flow (BF) heterogeneity, but its causes remain poorly understood. A biophysical model of human coronary vasculature was used to explain the imaging observations, and highlight causes of coronary BF heterogeneity. Post-dialysis CT images from patients under control, pharmacological stress (adenosine), therapy (cooled dialysate), and adenosine and cooled dialysate conditions were obtained. The data presented disparate phenotypes. To dissect vascular mechanisms, a 3D human vasculature model based on known experimental coronary morphometry and a space filling algorithm was implemented. Steady state simulations were performed to investigate the effects of altered aortic pressure and blood vessel diameters on myocardial BF heterogeneity. Imaging showed that stress and therapy potentially increased mean and total BF, while reducing heterogeneity. BF histograms of one patient showed multi-modality. Using the model, it was found that total coronary BF increased as coronary perfusion pressure was increased. BF heterogeneity was differentially affected by large or small vessel blocking. BF heterogeneity was found to be inversely related to small blood vessel diameters. Simulation of large artery stenosis indicates that BF became heterogeneous (increase relative dispersion) and gave multi-modal histograms. The total transmural BF as well as transmural BF heterogeneity reduced due to large artery stenosis, generating large patches of very low BF regions downstream. Blocking of arteries at various orders showed that blocking larger arteries results in multi-modal BF histograms and large patches of low BF, whereas smaller artery blocking results in augmented relative dispersion and fractal dimension. Transmural heterogeneity was also affected. Finally, the effects of augmented aortic pressure in the presence of blood vessel blocking shows differential effects on BF heterogeneity as well as transmural BF. Improved aortic blood pressure may improve total BF. Stress and therapy may be effective if they dilate small vessels. A potential cause for the observed complex BF distributions (multi-modal BF histograms) may indicate existing large vessel stenosis. The intuitive BF heterogeneity methods used can be readily used in clinical studies. Further development of the model and methods will permit personalized assessment of patient BF status. PMID:29867555
Gender affects sympathetic and hemodynamic response to postural stress
NASA Technical Reports Server (NTRS)
Shoemaker, J. K.; Hogeman, C. S.; Khan, M.; Kimmerly, D. S.; Sinoway, L. I.
2001-01-01
We tested the hypothesis that differences in sympathetic reflex responses to head-up tilt (HUT) between males (n = 9) and females (n = 8) were associated with decrements in postural vasomotor responses in women. Muscle sympathetic nerve activity (MSNA; microneurography), heart rate, stroke volume (SV; Doppler), and blood pressure (Finapres) were measured during a progressive HUT protocol (5 min at each of supine, 20 degrees, 40 degrees, and 60 degrees ). MSNA and hemodynamic responses were also measured during the cold pressor test (CPT) to examine nonbaroreflex neurovascular control. SV was normalized to body surface area (SV(i)) to calculate the index of cardiac output (Q(i)), and total peripheral resistance (TPR). During HUT, heart rate increased more in females versus males (P < 0.001) and SV(i) and Q(i) decreased similarly in both groups. Mean arterial pressure (MAP) increased to a lesser extent in females versus males in the HUT (P < 0.01) but increases in TPR during HUT were similar. MSNA burst frequency was lower in females versus males in supine (P < 0.03) but increased similarly during HUT. Average amplitude/burst increased in 60 degrees HUT for males but not females. Both males and females demonstrated an increase in MAP as well as MSNA burst frequency, mean burst amplitude, and total MSNA during the CPT. However, compared with females, males demonstrated a greater neural response (DeltaTotal MSNA) due to a larger increase in mean burst amplitude (P < 0.05). Therefore, these data point to gender-specific autonomic responses to cardiovascular stress. The different MSNA response to postural stress between genders may contribute importantly to decrements in blood pressure control during HUT in females.
Influence of Total Knee Arthroplasty on Patellar Kinematics and Patellofemoral Pressure.
Tanikawa, Hidenori; Tada, Mitsunori; Harato, Kengo; Okuma, Kazunari; Nagura, Takeo
2017-01-01
Patellofemoral complications are one of the main problems after total knee arthroplasty (TKA). The design of the TKA component may affect the patellar biomechanics, which may be associated with this postoperative complication. The purpose of this study was to assess the influence of TKA and prosthesis designs on the patellar kinematics and patellofemoral pressure. Using fresh-frozen cadavers, we measured the patellofemoral pressure, patella offset, and patella tilt in the following 4 conditions: normal knee (patella replacement only), cruciate-retaining TKA, condylar-stabilizing TKA, and posterior-stabilized TKA. The patellofemoral pressure increased significantly after the cruciate-retaining TKA and condylar-stabilizing TKA compared with the normal knee. The patella offset in the normal knee decreased with increasing knee flexion angles, while the patella offset in the TKA knees did not change significantly through the full range of motion. The amount of lateral patella tilt in the normal knee was significantly larger than the TKA knees in the full range of motion. Although the femoral components are designed to reproduce an anatomical patellar tracking, the physiological patellar kinematics were not observed. Relatively high patellofemoral pressure and kinematic change after TKA may be associated with postoperative complications such as the anterior knee pain. Copyright © 2016 Elsevier Inc. All rights reserved.
Mild pressure induces rapid accumulation of neutral lipid (triacylglycerol) in Chlorella spp.
Praveenkumar, Ramasamy; Kim, Bohwa; Lee, Jiye; Vijayan, Durairaj; Lee, Kyubock; Nam, Bora; Jeon, Sang Goo; Kim, Dong-Myung; Oh, You-Kwan
2016-11-01
Effective enhancement of neutral lipid (especially triacylglycerol, TAG) content in microalgae is an important issue for commercialization of microalgal biorefineries. Pressure is a key physical factor affecting the morphological, physiological, and biochemical behaviors of organisms. In this paper, we report a new stress-based method for induction of TAG accumulation in microalgae (specifically, Chlorella sp. KR-1 and Ch. sp. AG20150) by very-short-duration application of mild pressure. Pressure treatments of 10-15bar for 2h resulted in a considerable, ∼55% improvement of the 10-100g/Lcells' TAG contents compared with the untreated control. The post-pressure-treatment increase of cytoplasmic TAG granules was further confirmed by transmission electron microscopy (TEM). Notwithstanding the increased TAG content, the total lipid content was not changed by pressurization, implying that pressure stress possibly induces rapid remodeling/transformation of algal lipids rather than de novo biosynthesis of TAG. Copyright © 2016 Elsevier Ltd. All rights reserved.
System Mass Variation and Entropy Generation in 100k We Closed-Brayton-Cycle Space Power Systems
NASA Technical Reports Server (NTRS)
Barrett, Michael J.; Reid, Bryan M.
2004-01-01
State-of-the-art closed-Brayton-cycle (CBC) space power systems were modeled to study performance trends in a trade space characteristic of interplanetary orbiters. For working-fluid molar masses of 48.6, 39.9, and 11.9 kg/kmol, peak system pressures of 1.38 and 3.0 MPa and compressor pressure ratios ranging from 1.6 to 2.4, total system masses were estimated. System mass increased as peak operating pressure increased for all compressor pressure ratios and molar mass values examined. Minimum mass point comparison between 72 percent He at 1.38 MPa peak and 94 percent He at 3.0 MPa peak showed an increase in system mass of 14 percent. Converter flow loop entropy generation rates were calculated for 1.38 and 3.0 MPa peak pressure cases. Physical system behavior was approximated using a pedigreed NASA Glenn modeling code, Closed Cycle Engine Program (CCEP), which included realistic performance prediction for heat exchangers, radiators and turbomachinery.
System Mass Variation and Entropy Generation in 100-kWe Closed-Brayton-Cycle Space Power Systems
NASA Technical Reports Server (NTRS)
Barrett, Michael J.; Reid, Bryan M.
2004-01-01
State-of-the-art closed-Brayton-cycle (CBC) space power systems were modeled to study performance trends in a trade space characteristic of interplanetary orbiters. For working-fluid molar masses of 48.6, 39.9, and 11.9 kg/kmol, peak system pressures of 1.38 and 3.0 MPa and compressor pressure ratios ranging from 1.6 to 2.4, total system masses were estimated. System mass increased as peak operating pressure increased for all compressor pressure ratios and molar mass values examined. Minimum mass point comparison between 72 percent He at 1.38 MPa peak and 94 percent He at 3.0 MPa peak showed an increase in system mass of 14 percent. Converter flow loop entropy generation rates were calculated for 1.38 and 3.0 MPa peak pressure cases. Physical system behavior was approximated using a pedigreed NASA Glenn modeling code, Closed Cycle Engine Program (CCEP), which included realistic performance prediction for heat exchangers, radiators and turbomachinery.
DuRaine, G D; Athanasiou, K A
2015-04-01
The objective of this study was to identify ERK 1/2 involvement in the changes in compressive and tensile mechanical properties associated with hydrostatic pressure treatment of self-assembled cartilage constructs. In study 1, ERK 1/2 phosphorylation was detected by immunoblot, following application of hydrostatic pressure (1 h of static 10 MPa) applied at days 10-14 of self-assembly culture. In study 2, ERK 1/2 activation was blocked during hydrostatic pressure application on days 10-14. With pharmacological inhibition of the ERK pathway by the MEK1/ERK inhibitor U0126 during hydrostatic pressure application on days 10-14, the increase in Young's modulus induced by hydrostatic pressure was blocked. Furthermore, this reduction in Young's modulus with U0126 treatment during hydrostatic pressure application corresponded to a decrease in total collagen expression. However, U0126 did not inhibit the increase in aggregate modulus or GAG induced by hydrostatic pressure. These findings demonstrate a link between hydrostatic pressure application, ERK signalling and changes in the biomechanical properties of a tissue-engineered construct. Copyright © 2012 John Wiley & Sons, Ltd.
DuRaine, G D; Athanasiou, K A
2015-01-01
The objective of this study was to identify the ERK 1/2 involvement in the changes in compressive and tensile mechanical properties associated with hydrostatic pressure treatment of self-assembled cartilage constructs. In study 1, ERK 1/2 phosphorylation was detected by immunoblot following application of hydrostatic pressure (1 hour of static 10MPa) applied at day 10-14 of self-assembly culture. In study 2, ERK 1/2 activation was blocked during hydrostatic pressure application on days 10-14. With pharmacological inhibition of the ERK pathway by the MEK1/ERK inhibitor U0126 during hydrostatic pressure application on days 10-14, the increase in Young’s modulus induced by hydrostatic pressure was blocked. Furthermore, this reduction in Young’s modulus with U0126 treatment during hydrostatic pressure application corresponded with a decrease in total collagen expression. However, U0126 did not inhibit the increase in aggregate modulus or GAG induced by hydrostatic pressure. These findings demonstrate a link between hydrostatic pressure application, ERK signaling, and changes in biomechanical properties of a tissue engineered construct. PMID:23255524
Ramezankhani, Azra; Mehrabi, Yadollah; Mirmiran, Parvin; Azizi, Fereidoun
2011-01-01
A country's developmental progress and overall changes in socio-economic structure are reflected in the outcome of secular trend studies on physical growth of children. The aim of this study was to compare anthropometric and biochemical indices of adolescent boys and girls born during and after the Iran-Iraq war. Adolescents, aged 11 - 18 years, were selected from the TLGS cohort and divided into two groups. In the first group, adolescents born during the war and in the second group adolescents born after the war were included. Height, weight, serum lipids, FBS, systolic and diastolic blood pressure, and BMI were compared amongst adolescents of the same ages between the two groups. Mean weight and height increased at the ages of 12, 13, 14, and 17 years in boys of the post-war group. The mean weight of girls in the post-war group increased at the ages of 11, 13, and 14 years. Between 11 - 14 years, the means for total and LDL cholesterol, and between the ages of 15 - 18 years FBS, total cholesterol and LDL cholesterol decreased in boys of the post-war group. For girls between the ages of 11 - 14, FBS, total cholesterol, TG and LDL cholesterol, and between the ages of 15 - 18 years, FBS, total cholesterol and LDL cholesterol decreased in the post-war group. Systolic and diastolic blood pressure decreased at all ages in both groups. This study showed that some anthropometric indices such as height and weight increased in boys who were born after the war; but in girls, the mean weight in the age groups increased. Systolic and diastolic blood pressure, and some lipid profiles decreased in boys and girls of the post-war group.
Fibrous filter efficiency and pressure drop in the viscous-inertial transition flow regime.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanchez, Andres L.; Brockmann, John E.; Dellinger, Jennifer Gwynne
2011-10-01
Fibrous filter pressure drop and aerosol collection efficiency were measured at low air pressures (0.2 to 0.8 atm) and high face velocities (5 to 20 meters per second) to give fiber Reynolds numbers in the viscous-inertial transition flow regime (1 to 16). In this regime, contemporary filtration theory based on Kuwabara's viscous flow through an ensemble of fibers under-predicts single fiber impaction by several orders of magnitude. Streamline curvature increases substantially as inertial forces become dominant. Dimensionless pressure drop measurements followed the viscous-inertial theory of Robinson and Franklin rather than Darcy's linear pressure-velocity relationship (1972). Sodium chloride and iron nano-agglomeratemore » test aerosols were used to evaluate the effects of particle density and shape factor. Total filter efficiency collapsed when plotted against the particle Stokes and fiber Reynolds numbers. Efficiencies were then fitted with an impactor type equation where the cutpoint Stokes number and a steepness parameter described data well in the sharply increasing portion of the curve (20% to 80% efficiency). The cutpoint Stokes number was a linearly decreasing function of fiber Reynolds number. Single fiber efficiencies were calculated from total filter efficiencies and compared to contemporary viscous flow impaction theory (Stechkina et al. 1969), and numerical simulations from the literature. Existing theories under-predicted measured single fiber efficiencies although the assumption of uniform flow conditions for each successive layer of fibers is questionable; the common exponential relationship between single fiber efficiency and total filter efficiency may not be appropriate in this regime.« less
Oxidative stress and acute-phase response in patients with pressure sores.
Cordeiro, Maria Bernarda Cavalcanti; Antonelli, Elida Juliana; da Cunha, Daniel Ferreira; Júnior, Alceu Afonso Jordão; Júnior, Virmondes Rodrigues; Vannucchi, Helio
2005-09-01
We investigated the relation between oxidative stress and the occurrence of the acute-phase response with serum ascorbic acid and alpha-tocopherol levels in patients with pressure sores. The following groups of patients were studied: 1) those who had patients with pressure sores, 2) those who had pneumonia, and 3) those who did not develop pressure sores or any type of infection (control). Concentrations of total proteins, albumin, creatinine, iron, ferritin, transferrin, C-reactive protein, alpha1-acid glycoprotein, total iron-binding capacity, ascorbic acid, alpha-tocopherol, and malondialdehyde were measured during the first days of hospitalization. Albumin concentrations were significantly lower (P < 0.05) and C-reactive protein concentrations were significantly higher (P < 0.05) in patients with pressure sores compared with controls. Concentrations of ascorbic acid and alpha-tocopherol were significantly decreased (P < 0.05) in patients who had pressure sores or infection, whereas malondialdehyde concentrations were significantly increased (P < 0.05) compared with control patients. Five of 11 patients (55.56%) with pressure sores and 10 of 12 patients (83.33%) with pneumonia presented serum ascorbic acid concentrations below the reference value (34 to 91 micromol/L). Concentrations of ascorbic acid and alpha-tocopherol versus malondialdehyde were significantly correlated in the three patient groups (r = -0.44, P < 0.05; r = -0.55, P < 0.01, respectively). Patients with pressure sores and acute infection present a systemic inflammatory response accompanied by an increase in lipid peroxidation that is associated with decreased serum ascorbic acid and alpha-tocopherol levels, suggesting that these patients may be at risk for important nutritional deficiencies.
NASA Astrophysics Data System (ADS)
Fukui, K.; Machida, S.; Miyashita, Y.; Yoshizumi, M.; Angelopoulos, V.
2017-12-01
Substorms and pseudosubstorms (pseudobreakups) are very similar phenomena. In terms of auroral morphology, pseudosubstorms are generally more localized and more short-lived, compared with substorms, and are not accompanied by poleward expansion. We examined auroral development for events from November 2007 through April 2010, using data from THEMIS all-sky imagers. We defined events accompanied and not accompanied by poleward expansion as substorms and pseudosubstorms, respectively. To understand the cause of auroral development, we investigated temporal and spatial development of the near-Earth magnetotail during substorms and pseudosubstorms, based on superposed epoch analysis of THEMIS data. We find that Vx begins to increase at -9.5 >X(GSM)>-11.5 Re around onset for both substorms and pseudosubstorms. This seems to be due to earthward flows caused by magnetic reconnection. The northward Bz also increases around onset at -9.5 >X>-10.5 Re both substorms and pseudosubstorms. The amount and rate of Bz change are larger for substorms than for pseudosubstorms. In the earthward (-7.5 >X>-9.5 Re) and tailward (-10.5 >X>-12.5 Re) regions, Bz increases substantially for substorms, whereas it does not increase very much for pseudosubstorms. These results indicate that dipolarization is weaker for pseudosubstorms than for substorms, and the dipolarization region does not spread extensively for pseudosubstorms. We, therefore, suggest that current disruption related to dipolarization does not develop tailward and hence auroral poleward expansion does not occur for pseudosubstorms. Meanwhile, the plasma and magnetic pressures increase at -6.5 >X>-7.5 Re after onset in association with dipolarization, particularly for substorms. The total pressure (the sum of the plasma and magnetic pressures) prior to the onset is larger in that region for substorms than for pseudosubstorms. At -7.5 >X>-8.5 Re the total pressure hardly differ between substorms and pseudosubstorms. Thus we conclude that the spatial gradient of the total pressure is a key that determines whether the current disruption takes place, that is, whether initial activation develops into a substorm or into a subsiding pseudosubstorm.
Zhao, W H; Xu, H Q; Zhang, X; Wang, J I; Yin, C C; Li, M; Chen, J S
2000-09-01
The purpose of this study was to examine the effects of BMI (Body Mass Index) and WHR (Waist Hip Ratio) on average blood pressure and the prevalence of hypertension in middle-aged and elderly population in rural China. A total of 12955 subjects including 6276 males and 6688 females over 40 years of age were surveyed. Height, weight, waist circumference, hip circumference and blood pressure were measured. The association of BMI and WHR on average blood pressure levels and prevalence of hypertension were analyzed by dividing BMI and WHR into tertiles. The average blood pressure levels and the prevalence of hypertension in males and females increased significantly with the increase of BMI or WHR (P < 0.01), as well as with the increase of both of them (P < 0.01). The average blood pressure and the prevalence of hypertension stopped increasing when WHR was > or = 0.76, suggesting that WHR > or = 0.80 could be used as a cut-off value for the prediction of hypertension risk for both males and females. Therefore hypertension could be effectively prevented and controlled by controlling BMI and WHR.
Donor solvent coal liquefaction with bottoms recycle at elevated pressure
Bauman, Richard F.; Taunton, John W.; Anderson, George H.; Trachte, Ken L.; Hsia, Steve J.
1982-01-01
An improved process for liquefying solid carbonaceous materials wherein increased naphtha yields are achieved by effecting the liquefaction at a pressure within the range from about 1750 to about 2800 psig in the presence of recycled bottoms and a hydrogen-donor solvent containing at least 0.8 wt % donatable hydrogen. The liquefaction is accomplished at a temperature within the range from about 700.degree. to about 950.degree. F. The coal:bottoms ratio in the feed to liquefaction will be within the range from about 1:1 to about 5:1 and the solvent or diluent to total solids ratio will be at least 1.5:1 and preferably within the range from about 1.6:1 to about 3:1. The yield of naphtha boiling range materials increases as the pressure increases but generally reaches a maximum at a pressure within the range from about 2000 to about 2500 psig.
Ogilvie, R I; Zborowska-Sluis, D
1995-11-01
The relationship between stressed and total blood volume, total vascular capacitance, central blood volume, cardiac output (CO), and pulmonary capillary wedge pressure (Ppcw) was investigated in pacing-induced acute and chronic heart failure. Acute heart failure was induced in anesthetized splenectomized dogs by a volume load (20 mL/kg over 10 min) during rapid right ventricular pacing at 250 beats/min (RRVP) for 60 min. Chronic heart failure was induced by continuous RRVP for 2-6 weeks (average 24 +/- 2 days). Total vascular compliance and capacitance were calculated from the mean circulatory filling pressure (Pmcf) during transient circulatory arrest after acetylcholine at three different circulating volumes. Stressed blood volume was calculated as a product of compliance and Pmcf, with the total blood volume measured by a dye dilution. Central blood volume (CBV) and CO were measured by thermodilution. Central (heart and lung) vascular capacitance was estimated from the plot of Ppcw against CBV. Acute volume loading without RRVP increased capacitance and CO, whereas after volume loading with RRVP, capacitance and CO were unaltered from baseline. Chronic RRVP reduced capacitance and CO. All interventions, volume +/- RRVP or chronic RRVP, increased stressed and central blood volumes and Ppcw. Acute or chronic RRVP reduced central vascular capacitance. Cardiac output was increased when stressed and unstressed blood volumes increased proportionately as during volume loading alone. When CO was reduced and Ppcw increased, as during chronic RRVP or acute RRVP plus a volume load, stressed blood volume was increased and unstressed blood volume was decreased. Thus, interventions that reduced CO and increased Ppcw also increased stressed and reduced unstressed blood volume and total vascular capacitance.
Farvid, M S; Homayouni, F; Kashkalani, F; Shirzadeh, L; Valipour, G; Farahnak, Z
2013-03-01
The objective of this study was to investigate the potential associations between oxygen radical absorbance capacity (ORAC) of fruits, vegetables, legumes and nuts, and blood pressure in type 2 diabetic patients in Tehran. In a cross-sectional study of 506 type 2 diabetic patients, aged 28-75 years, usual dietary intakes were assessed by means of a 168-item food-frequency questionnaire. To calculate the estimated hydrophilic-ORAC, total ORAC, and total phenolics (TP) of fruits, vegetables, legumes and nuts for each participant, we used the United States Department of Agriculture Database for ORAC. We examined the associations between total ORAC and TP scores, and hypertension using logistic regression. After adjustment for potential confounders, a higher total ORAC score was associated with lower risk of hypertension. The odds ratios (ORs) of systolic blood pressure (SBP) >140 mm Hg across increasing quartiles of the total ORAC score were 1.0, 0.71, 0.38 and 0.56 (P for trend=0.016). The ORs of diastolic blood pressure (DBP) >90 mm Hg across increasing quartiles of the total ORAC score were 1.0, 0.59, 0.47 and 0.35 (P for trend=0.008). Further adjustment for energy, protein and sodium intakes slightly strengthened these associations. Multivariate ORs of elevated SBP across quartiles of TP score were 1.0, 0.83, 0.41 and 0.63 (P for trend=0.027), and for elevated DBP were 1.0, 0.50, 0.40 and 0.38 (P for trend=0.006). Further adjustment for energy, protein and sodium intakes did not change the results materially. Our findings suggest that total antioxidant capacity of the dietary intake was negatively associated with hypertension in type 2 diabetic patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Xiao; Yu, Peng-Cheng; Liu, Yu
2015-10-15
In our experiment, the transition points between the two operational modes of capacitive coupling (E mode) and inductive coupling (H mode) were investigated at a wide range of mercury vapor pressures in an inductively coupled plasma, varying with the input radio-frequency powers and the total filling pressures (10 Pa–30 Pa). The electron temperatures were calculated versus with the mercury vapor pressures for different values of the total filling pressures. The transition power points and electron density also were measured in this study. It is shown that the transition powers, whether the E to H mode transition or the H to E modemore » transition, are lower than that of the argon discharge, and these powers almost increase with the mercury vapor pressure rising. However, the transition electron density follows an inverse relationship with the mercury vapor pressures compared with the transition powers. In addition, at the lower pressures and higher mercury vapor pressures, an inverse hysteresis was observed clearly, which did not appear in the argon gas plasma. We suggest that all these results are attributed to the electron-neutral collision frequency changed with the additional mercury vapor pressures.« less
Aging-associated sensory neuropathy alters pressure-induced vasodilation in humans.
Fromy, Bérengère; Sigaudo-Roussel, Dominique; Gaubert-Dahan, Marie-Line; Rousseau, Pascal; Abraham, Pierre; Benzoni, Daniel; Berrut, Gilles; Saumet, Jean Louis
2010-03-01
Healthy skin is protected from pressure-induced ischemic damage because of the presence of pressure-induced vasodilation (PIV). PIV relies on small sensory nerve fibers and endothelial function. Since aging alters both nervous and vascular functions, we hypothesized that PIV is altered with aging. We compared PIV in non-neuropathic and neuropathic older subjects (60-75 years) with that of young subjects (20-35 years). Laser Doppler flowmetry was used to evaluate the cutaneous responses to local pressure application, acetylcholine, and local heating. Quantitative sensory tests were used to evaluate sensory-nerve-fiber function. The non-neuropathic older subjects had an impaired PIV (12+/-7% increase in blood flow with pressure) compared with young subjects (62+/-4%, P<0.001). In the presence of peripheral neuropathy, the older subjects were totally deprived of PIV, leading to early pressure-induced cutaneous ischemia (-31+/-10%, P<0.001). This inability of the skin to adapt to localized pressure in older subjects is related to the severity of the sensory-fiber dysfunction rather than to endothelial dysfunction, which was comparable between the non-neuropathic (141+/-19% increased blood flow with acetylcholine, P<0.05) and neuropathic older subjects (145+/-28% increase, P<0.05) compared with young subjects (234+/-25% increase).
The structure of MgO-SiO2 glasses at elevated pressure.
Wilding, Martin; Guthrie, Malcolm; Kohara, Shinji; Bull, Craig L; Akola, Jaakko; Tucker, Matt G
2012-06-06
The magnesium silicate system is an important geophysical analogue and neutron diffraction data from glasses formed in this system may also provide an initial framework for understanding the structure-dependent properties of related liquids that are important during planetary formation. Neutron diffraction data collected in situ for a single composition (38 mol% SiO(2)) magnesium silicate glass sample shows local changes in structure as pressure is increased from ambient conditions to 8.6 GPa at ambient temperature. A method for obtaining the fully corrected, total structure factor, S(Q), has been developed that allows accurate structural characterization as this weakly scattering glass sample is compressed. The measured S(Q) data indicate changes in chemical ordering with pressure and the real-space transforms show an increase in Mg-O coordination number and a distortion of the local environment around magnesium ions. We have used reverse Monte Carlo methods to compare the high pressure and ambient pressure structures and also compare the high pressure form with a more silica-poor glass (Mg(2)SiO(4)) that represents the approach to a more dense, void-free and topologically ordered structure. The Mg-O coordination number increases with pressure and we also find that the degree of continuous connectivity of Si-O bonds increases via a collapse of interstices.
Characterization of kerosene distribution around the ignition cavity in a scramjet combustor
NASA Astrophysics Data System (ADS)
Li, Xipeng; Liu, Weidong; Pan, Yu; Yang, Leichao; An, Bin; Zhu, Jiajian
2017-05-01
Kerosene distribution before its ignition in a scramjet combustor with dual cavity was measured using kerosene-PLIF under transverse injection upstream of the cavity and different injection pressures. The simulated flight condition is Ma 5.5, and the isolator entrance has a Mach number of 2.52, a total pressure of 1.6 MPa and a stagnation temperature of 1486 K. Effects of injection pressure on fuel distribution characteristics were analyzed. The majority of kerosene is present in the cavity shear layer as well as its upper region. Kerosene extends gradually into the cavity, almost, at a constant angle. Large scale structures are evident on the windward side of kerosene. The cavity shear layer plays an important role in determining the kerosene distribution and its entrainment into the cavity. The middle part of cavity is the most suitable location for ignition as a result of a favorable local equivalent ratio. As the injection pressure increases, the penetration height gets higher with the rate of increase getting slower at higher injection pressure. Meanwhile, the portion of kerosene entrained into cavity through shear layer becomes smaller as injection pressure increases. However, the kerosene entrained into cavity still increase due to the increased mass flow rate of kerosene.
Edwards, Meghan; Ley, Eric; Mirocha, James; Hadjibashi, Anoushiravan Amini; Margulies, Daniel R; Salim, Ali
2010-10-01
Hypotension, defined as systolic blood pressure less than 90 mm Hg, is recognized as a sign of hemorrhagic shock and is a validated prognostic indicator. The definition of hypotension, particularly in the elderly population, deserves attention. We hypothesized that the systolic blood pressure associated with increased mortality resulting from hemorrhagic shock increases with increasing age. The Los Angeles County Trauma Database was queried for all moderate to severely injured patients without major head injuries admitted between 1998 and 2005. Several fit statistic analyses were performed for each systolic blood pressure from 50 to 180 mm Hg to identify the model that most accurately defined hypotension for three age groups. The optimal definition of hypotension for each group was determined from the best fit model. A total of 24,438 patients were analyzed. The optimal definition of hypotension was systolic blood pressure of 100 mm Hg for patients 20 to 49 years, 120 mm Hg for patients 50 to 69 years, and 140 mm Hg for patients 70 years and older. The optimal systolic blood pressure for improved mortality in hemorrhagic shock increases significantly with increasing age. Elderly trauma patients without major head injuries should be considered hypotensive for systolic blood pressure less than 140 mm Hg.
NASA Technical Reports Server (NTRS)
Marcum, J. W.; Rachow, P.; Ferkul, P. V.; Olson, S. L.
2017-01-01
Low-pressure blowoff experiments were conducted with a stagnation flame stabilized on the forward tip of cast PMMA rods in a vertical wind tunnel. Pressure, forced flow velocity, gravity, and ambient oxygen concentration were varied. Stagnation flame blowoff is determined from a time-stamped video recording of the test. The blowoff pressure is determined from test section pressure transducer data that is synchronized with the time stamp. The forced flow velocity is also determined from the choked flow orifice pressure. Most of the tests were performed in normal gravity, but a handful of microgravity tests were also conducted to determine the influence of buoyant flow velocity on the blowoff limits. The blowoff limits are found to have a linear dependence between the partial pressure of oxygen and the total pressure, regardless of forced flow velocity and gravity level. The flow velocity (forced and/or buoyant) affects the blowoff pressure through the critical Damkohler number residence time, which dictates the partial pressure of oxygen at blowoff. This is because the critical stretch rate increases linearly with increasing pressure at low pressure (sub-atmospheric pressures) since a second-order overall reaction rate with two-body reactions dominates in this pressure range.
Elastic Properties across the y→α Volume Collapse in Cerium versus Pressure and Temperature
Lipp, M. J.; Jenei, Zs.; Cynn, H.; ...
2017-10-31
Here, the longitudinal and transverse sound speeds, c L and c T, of polycrystalline cerium were measured isothermally vs pressure up to the critical temperature across the iso-structural γ-α volume collapse (VC) phase transition. We deduce values for the adiabatic bulk modulus BS, the shear modulus G = ρc T 2, the Poisson’s ratio ν and the Debye temperature, θ D(p). We find that the elastic constant C 12 is solely responsible for the decrease of B S with pressure towards the VC at RT. With increasing temperature, the lattice contribution ΔS vib(γ→α) to the total entropy change across themore » VC decreases more rapidly to zero than the total entropy itself suggesting that another mechanism, possibly disorder, assists in stabilizing the γ-phase entropically against the α-phase. Also, with increasing temperature, the Poisson’s ratio becomes negative near the VC transition, meaning that cerium metal takes on auxetic characteristics over a small pressure range. At the critical point the Poisson’s ratio ought to be -1, since the isothermal bulk modulus vanishes and the shear modulus remains nonzero.« less
Elastic Properties across the y→α Volume Collapse in Cerium versus Pressure and Temperature
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lipp, M. J.; Jenei, Zs.; Cynn, H.
Here, the longitudinal and transverse sound speeds, c L and c T, of polycrystalline cerium were measured isothermally vs pressure up to the critical temperature across the iso-structural γ-α volume collapse (VC) phase transition. We deduce values for the adiabatic bulk modulus BS, the shear modulus G = ρc T 2, the Poisson’s ratio ν and the Debye temperature, θ D(p). We find that the elastic constant C 12 is solely responsible for the decrease of B S with pressure towards the VC at RT. With increasing temperature, the lattice contribution ΔS vib(γ→α) to the total entropy change across themore » VC decreases more rapidly to zero than the total entropy itself suggesting that another mechanism, possibly disorder, assists in stabilizing the γ-phase entropically against the α-phase. Also, with increasing temperature, the Poisson’s ratio becomes negative near the VC transition, meaning that cerium metal takes on auxetic characteristics over a small pressure range. At the critical point the Poisson’s ratio ought to be -1, since the isothermal bulk modulus vanishes and the shear modulus remains nonzero.« less
NASA Technical Reports Server (NTRS)
Geisenheyner, Robert M.; Berdysz, Joseph J.
1948-01-01
An investigation to determine the performance and operational characteristics of an axial-flow gas turbine-propeller engine was conducted in the Cleveland altitude wind tunnel. As part of this investigation, the combustion-chamber performance was determined at pressure altitudes from 5000 to 35,000 feet, compressor-inlet ram-pressure ratios of 1.00 and 1.09, and engine speeds from 8000 to 13,000 rpm. Combustion-chamber performance is presented as a function of corrected engine speed and corrected horsepower. For the range of corrected engine speeds investigated, overall total-pressure-loss ratio, cycle efficiency, and the fractional loss in cycle efficiency resulting from pressure losses in the combustion chambers were unaffected by a change in altitude or compressor-inlet ram-pressure ratio. For the range of corrected horsepowers investigated, the total-pressure-loss ratio and the fractional loss in cycle efficiency resulting from pressure losses in the combustion chambers decreased with an increase in corrected horsepower at a constant corrected engine speed. The combustion efficiency remained constant for the range of corrected horsepowers investigated at all corrected engine speeds.
The Effects of Popping Popcorn Under Reduced Pressure
NASA Astrophysics Data System (ADS)
Quinn, Paul; Cooper, Amanda
2008-03-01
In our experiments, we model the popping of popcorn as an adiabatic process and develop a process for improving the efficiency of popcorn production. By lowering the pressure of the popcorn during the popping process, we induce an increase in popcorn size, while decreasing the number of remaining unpopped kernels. In this project we run numerous experiments using three of the most common popping devices, a movie popcorn maker, a stove pot, and a microwave. We specifically examine the effects of varying the pressure on total sample size, flake size and waste. An empirical relationship is found between these variables and the pressure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Min, B.I.; Oguchi, T.; Jansen, H.J.F.
1986-07-15
Ground-state electronic and structural properties of Lu under pressure are investigated with use of the self-consistent all-electron total-energy linear muffin-tin orbital band-structure method within a local-density-functional approximation. Pressure-induced structural transitions are found to occur in the following sequence: hcp--(Sm-type)--dhcp--fcc, which is the same as that observed in the crystal structures of the trivalent rare-earth metals with decreasing atomic number. This structural transition is correlated with the increase in the number of d-italic electrons under pressure.
Comparison of plantar pressures and contact area between normal and cavus foot.
Fernández-Seguín, Lourdes M; Diaz Mancha, Juan Antonio; Sánchez Rodríguez, Raquel; Escamilla Martínez, Elena; Gómez Martín, Beatriz; Ramos Ortega, Javier
2014-02-01
In pes cavus, the medial longitudinal arch elevation reduces the contact surface area and consequently increases the corresponding plantar pressure measurements. This poor distribution of loads may produce associated pathology and pain in this or other areas of the body. Normal reference values need to be established in order to determine which patterns are prone to pathology. To compare the plantar pressures and weight-bearing surface in a population with pes cavus to a population with neutral feet. The sample comprised 68 adults, 34 with pes cavus and 34 with neutral feet. The Footscan USB Gait Clinical System(®) was used as a platform to measure the total contact area and plantar pressure under the forefoot, midfoot, hindfoot, each metatarsal head, and the overall metatarsal area. A statistical analysis of the data was performed using Student's t-test for independent samples. The pes cavus subjects showed a significant reduction in their weight-bearing area [neutral feet: 165.04 ( ± 20.68) cm(2); pes cavus: 118.26 ( ± 30.31) cm(2); p < 0.001] and significantly increased pressures under all zones of the forefoot except the fifth metatarsal [metatarsal pressure: in neutral feet 503,797 ( ± 9.32) kPa; in pes cavus 656.12 ( ± 22.39) kPa; p < 0.001]. Compared to neutral feet, pes cavus feet show a reduction in total contact surface and the load under the first toe. A significant increase is present in the load under the metatarsal areas, but the relative distribution of this load is similar in both groups. Copyright © 2013 Elsevier B.V. All rights reserved.
The OregonHeart Total Artificial Heart: Design and Performance on a Mock Circulatory Loop.
Glynn, Jeremy; Song, Howard; Hull, Bryan; Withers, Stanley; Gelow, Jill; Mudd, James; Starr, Albert; Wampler, Richard
2017-10-01
Widespread use of heart transplantation is limited by the scarcity of donor organs. Total artificial heart (TAH) development has been pursued to address this shortage, especially to treat patients who require biventricular support. We have developed a novel TAH that utilizes a continuously spinning rotor that shuttles between two positions to provide pulsatile, alternating blood flow to the systemic and pulmonary circulations without artificial valves. Flow rates and pressures generated by the TAH are controlled by adjusting rotor speed, cycle frequency, and the proportion of each cycle spent pumping to either circulation. To validate the design, a TAH prototype was placed in a mock circulatory loop that simulates vascular resistance, pressure, and compliance in normal and pathophysiologic conditions. At a systemic blood pressure of 120/80 mm Hg, nominal TAH output was 7.4 L/min with instantaneous flows reaching 17 L/min. Pulmonary artery, and left and right atrial pressures were all maintained within normal ranges. To simulate implant into a patient with severe pulmonary hypertension, the pulmonary vascular resistance of the mock loop was increased to 7.5 Wood units. By increasing pump speed to the pulmonary circulation, cardiac output could be maintained at 7.4 L/min as mean pulmonary artery pressure increased to 56 mm Hg while systemic blood pressures remained normal. This in vitro testing of a novel, shuttling TAH demonstrated that cardiac output could be maintained across a range of pathophysiologic conditions including pulmonary hypertension. These experiments serve as a proof-of-concept for the design, which has proceeded to in vivo testing. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Radial profile of pressure in a storm ring current as a function of D st
NASA Astrophysics Data System (ADS)
Kovtyukh, A. S.
2010-06-01
Using satellite data obtained near the equatorial plane during 12 magnetic storms with amplitudes from -61 down to -422 nT, the dependences of maximum in L-profile of pressure ( L m) of the ring current (RC) on the current value of D st are constructed, and their analytical approximations are derived. It is established that function L m( D st ) is steeper on the phase of recovery than during the storm’s main phase. The form of the outer edge of experimental radial profiles of RC pressure is studied, and it is demonstrated to correspond to exponential growth of the total energy of RC particles on a given L shell with decreasing L. It is shown that during the storms’ main phase the ratio of plasma and magnetic field pressures at the RC maximum does not practically depend on the storm strength and L m value. This fact reflects resistance of the Earth’s magnetic field to RC expansion, and testifies that during storms the possibilities of injection to small L are limited for RC particles. During the storms’ recovery phase this ratio quickly increases with increasing L m, which reflects an increased fraction of plasma in the total pressure balance. It is demonstrated that function L m( D st ) is derived for the main phase of storms from the equations of drift motion of RC ions in electrical and magnetic fields, reflecting the dipole character of magnetic field and scale invariance of the pattern of particle convection near the RC maximum. For the recovery phase it is obtained from the Dessler-Parker-Sckopke relationship. The obtained regularities allow one to judge about the radial profile of RC pressure from ground-based magnetic measurements (data on the D st variation).
[Anlysis of foot biomechanics characteristic in 303 patients with type 2 diabetes mellitus].
Li, Wen-Xia; Cao, Ying; Zou, Meng-Chen; Huang, Ying; Hu, Ping; Luo, Xiang-Rong; Jiang, Ya; Xue, Yao-Ming; Gao, Fang
2016-10-20
To investigate foot biomechanics characteristic of patients with type 2 diabetes mellitus. This study was conducted among 303 patients with type 2 diabetes. The whole foot was divided into 10 regions, namely the first toe (T1); the second to fifth toes (T2-5); the first, second, third, fourth, and fifth metatarsals (M1, M2, M3, M4, and M5, respectively); midfoot (MF), and the heel medial (HM). Foot arch index, foot angle and maximum peak pressure (MPP) of the 10 regions were measured using a Footscan gait system. The maximum peak pressure of 10 regions decreased in the order of M3>M2>HM>M4>HL>M1>M5>T1>ML>T2-5 for the left foot, and in the order of M3>M2>HM>M4>HL>M1>M5>T1>ML>T2-5 for the right foot. The MPP in M1 region was higher in the right than in the left foot (P<0.05). The MPP in M3, M4, M5, and MF was higher in the left than in the right foot (P<0.05). The percentage of high-risk foot (defined by a total plantar pressure ≥70 N/cm 2 ) was 34% on the left and 17.7% on the right. An increased BMI was associated with a significant increase in high-risk foot, but not for the right foot in underweight patients. Foot flat phase was extended and forefoot push-off phase shortened in stance phase in the patients. Compared with the right foot, the left foot showed a significantly increased foot arch index and increased low and high arch rates with a decreased normal arch rate. Total plantar pressure was higher in of the left high arch foot than in normal arch foot. The foot angle was significantly larger on the right than on the left. The bilateral total plantar pressures were significantly greater in male patients (P<0.05) and increased with age but were not associated with the duration of DM, foot angle, or glycosylated hemoglobin level. Diabetic patients have obvious alterations in foot biomechanics with abnormalities of the plantar pressure, and the percentage of high-risk foot increases in overweight and obese patients, suggesting the need of body weight control in these patients when administering offloading treatment for prevention of diabetic foot ulcer.
NASA Astrophysics Data System (ADS)
Lv, Zheng; Xu, Jinglei; Mo, Jianwei
2017-04-01
The performance of a single expansion ramp nozzle (SERN) is poor due to over-expansion at off-design conditions. The present study focuses on improving the SERN performance by secondary injection on the cowl and is carried out by using the k - ε RNG turbulence model. The incidence shock wave resulting from the secondary injection impinges on the expansion ramp, resulting in separation and the increase of the pressure distribution along the ramp. The performance of the SERN can be improved significantly, and the augmentation of the thrust coefficient, lift and pitch moment can be as high as 3.16%, 29.43% and 41.67%, respectively, when the nozzle pressure ratio (NPR) is 10. The location of the injection has a considerable effect on the lift and pitching moment, and the direction of the pitch moment can be changed from nose-up to nose-down when the injection is on the tail of the cowl. The effect of the injection on the axial thrust coefficient is much more apparent, if the operation NPR is far from the design point, and however, the results for the lift and pitching moment are opposite. The increases of injection total pressure and injection width have positive impacts on the SERN performance. And if the parameter φ maintains constant, the axial thrust coefficient would increase when the injection total pressure decreases, so low energy flow can also be used as the secondary injection without decreasing the lift and pitching moment. The mass flow rate of the injection can be decreased by applying the higher total temperature flow without reducing the performance of the SERN.
Schwartz, Bryan G; Qualls, Clifford; Kloner, Robert A; Laskey, Warren K
2015-10-15
A distinct seasonal pattern in total and cardiovascular death rates has been reported. The factors contributing to this pattern have not been fully explored. Seven locations (average total population 71,354,000) were selected where data were available including relatively warm, cold, and moderate temperatures. Over the period 2004 to 2009, there were 2,526,123 all-cause deaths, 838,264 circulatory deaths, 255,273 coronary heart disease deaths, and 135,801 ST-elevation myocardial infarction (STEMI) deaths. We used time series and multivariate regression modeling to explore the association between death rates and climatic factors (temperature, dew point, precipitation, barometric pressure), influenza levels, air pollution levels, hours of daylight, and day of week. Average seasonal patterns for all-cause and cardiovascular deaths were very similar across the 7 locations despite differences in climate. After adjusting for multiple covariates and potential confounders, there was a 0.49% increase in all-cause death rate for every 1°C decrease. In general, all-cause, circulatory, coronary heart disease and STEMI death rates increased linearly with decreasing temperatures. The temperature effect varied by location, including temperature's linear slope, cubic fit, positional shift on the temperature axis, and the presence of circulatory death increases in locally hot temperatures. The variable effect of temperature by location suggests that people acclimatize to local temperature cycles. All-cause and circulatory death rates also demonstrated sizable associations with influenza levels, dew point temperature, and barometric pressure. A greater understanding of how climate, temperature, and barometric pressure influence cardiovascular responses would enhance our understanding of circulatory and STEMI deaths. Copyright © 2015 Elsevier Inc. All rights reserved.
Cudnoch-Jedrzejewska, Agnieszka; Gomolka, Ryszard; Szczepanska-Sadowska, Ewa; Czarzasta, Katarzyna; Wrzesien, Robert; Koperski, Lukasz; Puchalska, Liana; Wsol, Agnieszka
2015-01-01
Central application of apelin elevates blood pressure and influences neuroendocrine responses to stress and food consumption. However, it is not known whether the central cardiovascular effects of apelin depend also on caloric intake or chronic stress. The purpose of the present study was to determine the effects of intracerebroventricular administration of apelin on blood pressure (mean arterial blood pressure) and heart rate in conscious Sprague-Dawley rats consuming either a normal-fat diet (NFD) or high-fat diet (HFD) for 12 weeks. During the last 4 weeks of the food regime, the rats were exposed (NFDS and HFDS groups) or not exposed (NFDNS and HFDNS groups) to chronic stress. Each group was divided into two subgroups receiving intracerebroventricular infusions of either vehicle or apelin. Apelin elicited significant increase of mean arterial blood pressure and heart rate in the NFDNS rats. This effect was abolished in the HFDNS, HFDS and NFDS groups. HFD resulted in a significant elevation of blood concentrations of total cholesterol, triglycerides glucose and insulin. Chronic stress reduced plasma concentration of total and high-density lipoprotein cholesterol, and increased plasma corticosterone concentration and APJ receptor mRNA expression in the hypothalamus, whereas a combination of a HFD with chronic stress resulted in the elevation of plasma triglycerides, total cholesterol and low-density lipoprotein cholesterol, and in increased plasma corticosterone concentration, apelin concentration and APJ receptor mRNA expression in the hypothalamus. It is concluded that a HFD and chronic stress result in significant suppression of the central pressor action of apelin, and cause significant though not unidirectional changes of metabolic and endocrine parameters. © 2014 Wiley Publishing Asia Pty Ltd.
Catino, Anna B; Hubbard, Rebecca A; Chirinos, Julio A; Townsend, Ray; Keefe, Stephen; Haas, Naomi B; Puzanov, Igor; Fang, James C; Agarwal, Neeraj; Hyman, David; Smith, Amanda M; Gordon, Mary; Plappert, Theodore; Englefield, Virginia; Narayan, Vivek; Ewer, Steven; ElAmm, Chantal; Lenihan, Daniel; Ky, Bonnie
2018-03-01
Sunitinib, used widely in metastatic renal cell carcinoma, can result in hypertension, left ventricular dysfunction, and heart failure. However, the relationships between vascular function and cardiac dysfunction with sunitinib are poorly understood. In a multicenter prospective study of 84 metastatic renal cell carcinoma patients, echocardiography, arterial tonometry, and BNP (B-type natriuretic peptide) measures were performed at baseline and at 3.5, 15, and 33 weeks after sunitinib initiation, correlating with sunitinib cycles 1, 3, and 6. Mean change in vascular function parameters and 95% confidence intervals were calculated. Linear regression models were used to estimate associations between vascular function and left ventricular ejection fraction, longitudinal strain, diastolic function (E/e'), and BNP. After 3.5 weeks of sunitinib, mean systolic blood pressure increased by 9.5 mm Hg (95% confidence interval, 2.0-17.1; P =0.02) and diastolic blood pressure by 7.2 mm Hg (95% confidence interval, 4.3-10.0; P <0.001) across all participants. Sunitinib resulted in increases in large artery stiffness (carotid-femoral pulse wave velocity) and resistive load (total peripheral resistance and arterial elastance; all P <0.05) and changes in pulsatile load (total arterial compliance and wave reflection). There were no statistically significant associations between vascular function and systolic dysfunction (left ventricular ejection fraction and longitudinal strain). However, baseline total peripheral resistance, arterial elastance, and aortic impedance were associated with worsening diastolic function and filling pressures over time. In patients with metastatic renal cell carcinoma, sunitinib resulted in early, significant increases in blood pressure, arterial stiffness, and resistive and pulsatile load within 3.5 weeks of treatment. Baseline vascular function parameters were associated with worsening diastolic but not systolic function. © 2018 American Heart Association, Inc.
NASA Technical Reports Server (NTRS)
Gensenheyner, Robert M.; Berdysz, Joseph J.
1947-01-01
An investigation to determine the performance and operational characteristics of the TG-1OOA gas turbine-propeller engine was conducted in the Cleveland altitude wind tunnel. As part of this investigation, the combustion-chamber performance was determined at pressure altitudes from 5000 to 35,000 feet, compressor-inlet rm-pressure ratios of 1.00 and 1.09, and engine speeds from 8000 to 13,000 rpm. Combustion-chamber performance is presented as a function of corrected engine speed and.correcte& horsepower. For the range of corrected engine speeds investigated, over-all total-pressure-loss ratio, cycle efficiency, ana the frac%ional loss in cycle efficiency resulting from pressure losses in the combustion chambers were unaffected by a change in altitude or compressor-inlet ram-pressure ratio. The scatter of combustion- efficiency data tended to obscure any effect of altitude or ram-pressure ratio. For the range of corrected horse-powers investigated, the total-pressure-loss ratio an& the fractional loss in cycle efficiency resulting from pressure losses in the combustion chambers decreased with an increase in corrected horsepower at a constant corrected engine speed. The combustion efficiency remained constant for the range of corrected horse-powers investigated at all corrected engine speeds.
Schmidt, Eric; Ros, Maxime; Moyse, Emmanuel; Lorthois, Sylvie; Swider, Pascal
2016-01-01
In line with the first law of thermodynamics, Bernoulli's principle states that the total energy in a fluid is the same at all points. We applied Bernoulli's principle to understand the relationship between intracranial pressure (ICP) and intracranial fluids. We analyzed simple fluid physics along a tube to describe the interplay between pressure and velocity. Bernoulli's equation demonstrates that a fluid does not flow along a gradient of pressure or velocity; a fluid flows along a gradient of energy from a high-energy region to a low-energy region. A fluid can even flow against a pressure gradient or a velocity gradient. Pressure and velocity represent part of the total energy. Cerebral blood perfusion is not driven by pressure but by energy: the blood flows from high-energy to lower-energy regions. Hydrocephalus is related to increased cerebrospinal fluid (CSF) resistance (i.e., energy transfer) at various points. Identification of the energy transfer within the CSF circuit is important in understanding and treating CSF-related disorders. Bernoulli's principle is not an abstract concept far from clinical practice. We should be aware that pressure is easy to measure, but it does not induce resumption of fluid flow. Even at the bedside, energy is the key to understanding ICP and fluid dynamics.
Schwarzer, Michael; Schrepper, Andrea; Amorim, Paulo A; Osterholt, Moritz; Doenst, Torsten
2013-02-15
Years ago a debate arose as to whether two functionally different mitochondrial subpopulations, subsarcolemmal mitochondria (SSM) and interfibrillar mitochondria (IFM), exist in heart muscle. Nowadays potential differences are often ignored. Presumably, SSM are providing ATP for basic cell function, whereas IFM provide energy for the contractile apparatus. We speculated that two distinguishable subpopulations exist that are differentially affected by pressure overload. Male Sprague-Dawley rats were subjected to transverse aortic constriction for 20 wk or sham operation. Contractile function was assessed by echocardiography. Heart tissue was analyzed by electron microscopy. Mitochondria were isolated by differential centrifugation, and respiratory capacity was analyzed using a Clark electrode. Pressure overload induced left ventricular hypertrophy with increased posterior wall diameter and impaired contractile function. Mitochondrial state 3 respiration in control was 50% higher in IFM than in SSM. Pressure overload significantly impaired respiratory rates in both IFM and SSM, but in SSM to a lower extent. As a result, there were no differences between SSM and IFM after 20 wk of pressure overload. Pressure overload reduced total citrate synthase activity, suggesting reduced total mitochondrial content. Electron microscopy revealed normal morphology of mitochondria but reduced total mitochondrial volume density. In conclusion, IFM show greater respiratory capacity in the healthy rat heart and a greater depression of respiratory capacity by pressure overload than SSM. The differences in respiratory capacity of cardiac IFM and SSM in healthy hearts are eliminated with pressure overload-induced heart failure. The strong effect of pressure overload on IFM together with the simultaneous appearance of mitochondrial and contractile dysfunction may support the notion of IFM primarily producing ATP for contractile function.
Hyvärinen, Antti-Pekka; Brus, David; Zdímal, Vladimír; Smolík, Jiri; Kulmala, Markku; Viisanen, Yrjö; Lihavainen, Heikki
2006-06-14
Homogeneous nucleation rate isotherms of n-butanol+helium were measured in a laminar flow diffusion chamber at total pressures ranging from 50 to 210 kPa to investigate the effect of carrier gas pressure on nucleation. Nucleation temperatures ranged from 265 to 280 K and the measured nucleation rates were between 10(2) and 10(6) cm(-3) s(-1). The measured nucleation rates decreased as a function of increasing pressure. The pressure effect was strongest at pressures below 100 kPa. This negative carrier gas effect was also temperature dependent. At nucleation temperature of 280 K and at the same saturation ratio, the maximum deviation between nucleation rates measured at 50 and 210 kPa was about three orders of magnitude. At nucleation temperature of 265 K, the effect was negligible. Qualitatively the results resemble those measured in a thermal diffusion cloud chamber. Also the slopes of the isothermal nucleation rates as a function of saturation ratio were different as a function of total pressure, 50 kPa isotherms yielded the steepest slopes, and 210 kPa isotherms the shallowest slopes. Several sources of inaccuracies were considered in the interpretation of the results: uncertainties in the transport properties, nonideal behavior of the vapor-carrier gas mixture, and shortcomings of the used mathematical model. Operation characteristics of the laminar flow diffusion chamber at both under-and over-pressure were determined to verify a correct and stable operation of the device. We conclude that a negative carrier gas pressure effect is seen in the laminar flow diffusion chamber and it cannot be totally explained with the aforementioned reasons.
Woo, Seung Hoon; Kim, Jin Pyeong; Park, Jung Je; Shim, Hyun Seok; Lee, Sang Ha; Lee, Ho Joong; Won, Seong Jun; Son, Hee Young; Kim, Rock Bum; Son, Young-Ik
2013-01-01
The aim of this study was to compare a negative pressure drain with a natural drain in order to determine whether a negative pressure drainage tube causes an increase in the drainage volume. Sixty-two patients who underwent total thyroidectomy for papillary thyroid carcinoma (PTC) were enrolled in the study between March 2010 and August 2010 at Gyeongsang National University Hospital. The patients were prospectively and randomly assigned to two groups, a negative pressure drainage group (n=32) and natural drainage group (n=30). Every 3 hours, the volume of drainage was checked in the two groups until the tube was removed. The amount of drainage during the first 24 hours postoperatively was 41.68 ± 3.93 mL in the negative drain group and 25.3 ± 2.68 mL in the natural drain group (p<0.001). After 24 additional hours, the negative drain group was 35.19 ± 4.26 mL and natural drain groups 21.53 ± 2.90 mL (p<0.001). However, the drainage at postoperative day 3 was not statistically different between the two groups. In addition, the vocal cord palsy and temporary and permanent hypocalcemia were not different between the two groups. These results indicate that a negative pressure drain may increase the amount of drainage during the first 24-48 hours postoperatively. Therefore, it is not necessary to place a closed suction drain when only a total thyroidectomy is done.
NASA Astrophysics Data System (ADS)
Yang, Ruike; Zhu, Chuanshuai; Wei, Qun; Du, Zheng
2016-11-01
The lattice parameters, cell volume, elastic constants, bulk modulus, shear modulus, Young's modulus and Poisson's ratio are calculated at zero pressure, and their values are in excellent agreement with the available data, for TiN, Ti2N and Ti3N2. By using the elastic stability criteria, it is shown that the three structures are all stable. The brittle/ductile behaviors are assessed in the pressures from 0 GPa to 50 GPa. Our calculations present that the performances for TiN, Ti2N and Ti3N2 become from brittle to ductile with pressure rise. The Debye temperature rises as pressure increase. With increasing N content, the enhancement of covalent interactions and decline of metallicity lead to the increase of the micro-hardness. Their constant volume heat capacities increase rapidly in the lower temperature, at a given pressure. At higher temperature, the heat capacities are close to the Dulong-Petit limit, and the heat capacities of TiN and Ti2N are larger than that of c-BN. The thermal expansion coefficients of titanium nitrides are slightly larger than that of c-BN. The band structure and the total Density of States (DOS) are calculated at 0 GPa and 50 GPa. The results show that TiN and Ti2N present metallic character. Ti3N2 present semiconducting character. The band structures have some discrepancies between 0 GPa and 50 GPa. The extent of energy dispersion increases slightly at 50 GPa, which means that the itinerant character of electrons becomes stronger at 50 GPa. The main bonding peaks of TiN, Ti2N and Ti3N2 locate in the range from -10 to 10 eV, which originate from the contribution of valance electron numbers of Ti s, Ti p, Ti d, N s and N p orbits. We can also find that the pressure makes that the total DOS decrease at the Fermi level for Ti2N. The bonding behavior of N-Ti compounds is a combination of covalent and ionic nature. As N content increases, valence band broadens, valence electron concentration increases, and covalent interactions become stronger. This is reflected in shortening of Ti-N bonds.
Pathophysiological effect of fat embolism in a canine model of pulmonary contusion.
Elmaraghy, A W; Aksenov, S; Byrick, R J; Richards, R R; Schemitsch, E H
1999-08-01
The objective of this study was to determine the individual and combined effects of pulmonary contusion and fat embolism on the hemodynamics and pulmonary pathophysiology in a canine model of acute traumatic pulmonary injury. After a thoracotomy, twenty-one skeletally mature dogs were randomly assigned to one of three groups. Unilateral pulmonary contusion alone was produced in Group 1 (seven dogs); pulmonary contusion and fat embolism, in Group 2 (seven dogs); and fat embolism alone, in Group 3 (seven dogs). Pulmonary contusion was produced by standardized compression of the left lung with a piezoelectric force transducer. Fat embolism was produced by femoral and tibial reaming followed by pressurization of the intramedullary canals. Cardiac output, systolic blood pressure, peak airway pressure, pulmonary arterial pressure, pulmonary capillary wedge pressure, partial pressure of arterial oxygen, and partial pressure of carbon dioxide were monitored for all groups. From these data, several outcome parameters were calculated: total thoracic compliance, alveolar-arterial oxygen gradient, and ratio of partial pressure of arterial oxygen to fractional inspired oxygen concentration. All of the dogs were killed after eight hours, and tissue samples were obtained from the brain, kidneys, and lungs for histological analysis. Lung samples were assigned scores for pulmonary edema (the presence of fluid in the alveoli) and inflammation (the presence of neutrophils or hyaline membranes, or both). The percentage of the total area occupied by fat was determined. Pulmonary contusion alone caused a significant increase in the alveolar-arterial oxygen gradient but only after seven hours (p = 0.034). Fat embolism alone caused a significant transient decrease in systolic blood pressure (p = 0.001) and a significant transient increase in pulmonary arterial pressure (p = 0.01) and pulmonary capillary wedge pressure (p = 0.015). Fat embolism alone also caused a significant sustained decrease in the ratio of partial pressure of arterial oxygen to fractional inspired oxygen concentration (p = 0.0001) and a significant increase in the alveolar-arterial oxygen gradient (p = 0.0001). The combination of pulmonary contusion and fat embolism caused a significant transient increase in pulmonary capillary wedge pressure (p = 0.0013) as well as a significant sustained decrease in partial pressure of arterial oxygen (p = 0.0001) and a significant decrease in systolic blood pressure (p = 0.001) that lasted for an hour. Pulmonary contusion followed by fat embolism caused a significant increase in peak airway pressure (p = 0.015), alveolar-arterial oxygen gradient (p = 0.0001), and pulmonary arterial pressure (p = 0.01), and these effects persisted for five hours. Total thoracic compliance was decreased 6.4 percent by pulmonary contusion alone, 4.6 percent by fat embolism alone, and 23.5 percent by pulmonary contusion followed by fat embolism. The ratio of partial pressure of arterial oxygen to fractional inspired oxygen concentration was decreased 23.7 percent by pulmonary contusion alone, 52.3 percent by fat embolism alone, and 65.8 percent by pulmonary contusion followed by fat embolism. The mean pulmonary edema score was significantly higher with the combined injury than with either injury alone (p = 0.0001). None of the samples from the lungs demonstrated inflammation. Fat embolism combined with pulmonary contusion resulted in a significantly greater mean percentage of the area occupied by fat in the noncontused right lung than in the contused left lung (p = 0.001); however, no significant difference between the right and left lungs could be detected with fat embolism alone. The mean percentage of the glomerular and cerebral areas occupied by fat was greater with fat embolism combined with pulmonary contusion than with fat embolism alone (p = 0.0001 and p = 0.01, respectively). (ABSTRACT TRUNCATED)
Irwig, M S; Sood, P; Ni, D; Amass, T; Khurana, P S; Jayanthi, V V; Wang, L; Adler, S M
2012-09-01
To test (1) whether a diabetes scorecard can improve glycaemic control, blood pressure control, LDL cholesterol, aspirin usage and exercise; (2) if the scorecard will motivate and/or educate patients to improve their scores for subsequent visits; and (3) whether the scorecard will improve rates of clinical inertia. Five physicians enrolled 103 patients ≥ 40 years old with uncontrolled Type 2 diabetes [HbA(1c) ≥ 64 mmol/mol (8.0%)] to randomly receive either a diabetes scorecard or not during four clinical visits over a 9-month period. The population was predominantly urban with a disproportionately higher percentage of black people than the general population. Our scorecard assigned points to six clinical variables, with a perfect total score of 100 points corresponding to meeting all targets. The primary outcomes were total scores and HbA(1c) in the scorecard and control groups at 9 months. There were no significant differences between the control and scorecard groups at visits 1 and 4 in total score, HbA(1c) , blood pressure, LDL cholesterol, aspirin usage, exercise or knowledge about diabetic targets. By visit 4 both the control and scorecard groups had statistically significant improvements with their mean total score (9 and 7 points, respectively), HbA(1c) [-9 mmol/mol (-0.8%) and -15 mmol/mol (-1.4%), respectively] and aspirin usage (33% increase and 16% increase, respectively). Rates of clinical inertia were low throughout the study. A diabetes scorecard did not improve glycaemic control, blood pressure control, LDL cholesterol, aspirin usage, exercise or diabetic knowledge in an urban population with uncontrolled Type 2 diabetes. © 2012 The Authors. Diabetic Medicine © 2012 Diabetes UK.
NASA Astrophysics Data System (ADS)
İşlek, Cemil; Murat Altuner, Ergin; Çeter, Talip; Alpas, Hami
2013-06-01
High hydrostatic pressure is a non-thermal food processing technology that is found to increase the percentage of germination, decrease the germination time and improve the microbial quality of seeds. In this study, pressures of 100-400 MPa for 10 min at 30°C are used to compare the percentage of germination, the microbial quality of seeds, chlorophyll a and b, and total phenolic compounds concentrations in seedlings, and the anatomy-morphology characteristics of garden cress. Enhanced reductions of total aerobic mesophilic bacteria, total and fecal coliforms, and yeast and mould populations in seeds were observed, especially at 300 MPa. In addition, the percentage of germination, chlorophyll content and phenolic compounds concentrations, fresh and dry weights, and hypocotyl lengths of the seedlings are higher than those of all samples, where the percentage of germination is equal to controls but higher than other samples, and radicula length is lower than controls but higher than others.
Riser, B L; Cortes, P; Zhao, X; Bernstein, J; Dumler, F; Narins, R G
1992-01-01
To define the interplay of glomerular hypertension and hypertrophy with mesangial extracellular matrix (ECM) deposition, we examined the effects of glomerular capillary distention and mesangial cell stretching on ECM synthesis. The volume of microdissected rat glomeruli (Vg), perfused ex vivo at increasing flows, was quantified and related to the proximal intraglomerular pressure (PIP). Glomerular compliance, expressed as the slope of the positive linear relationship between PIP and Vg was 7.68 x 10(3) microns 3/mmHg. Total Vg increment (PIP 0-150 mmHg) was 1.162 x 10(6) microns 3 or 61% (n = 13). A 16% increase in Vg was obtained over the PIP range equivalent to the pathophysiological limits of mean transcapillary pressure difference. A similar effect of renal perfusion on Vg was also noted histologically in tissue from kidneys perfused/fixed in vivo. Cultured mesangial cells undergoing cyclic stretching increased their synthesis of protein, total collagen, and key components of ECM (collagen IV, collagen I, laminin, fibronectin). Synthetic rates were stimulated by cell growth and the degree of stretching. These results suggest that capillary expansion and stretching of mesangial cells by glomerular hypertension provokes increased ECM production which is accentuated by cell growth and glomerular hypertrophy. Mesangial expansion and glomerulosclerosis might result from this interplay of mechanical and metabolic forces. Images PMID:1430216
Smagghe, G; Van Leeuwen, T
2004-01-01
In this paper, we determined some physico-chemical properties like osmotic pressure, pH and electrical conductivity of the hemolymph from caterpillars of Spodoptera littoralis (Lepidoptera: Noctuidae) during the last larval instar. It was of interest that we observed an increase in osmotic pressure with the increase in age in the last instar that may concur with the start of histolysis at metamorphosis. These physicochemical properties were then compared to those of Grace's and modified Grace's tissue culture medium. In addition, concentrations of the cations Na, K, Ca and Mg, and the anions Cl, NO3, PO4 and SO4 were determined in the insect hemolymph of S. littoralis. The cations K and Mg reached high values with a percent of about 52% of the total amount of cations. The concentration of sodium was low. The total sum of the anions consisted about 56 meq/1, and this allows to neutralise about 45 % of the total cations.
Epidural blood patch for refractory low CSF pressure headache: a pilot study.
Madsen, Søren Aalbæk; Fomsgaard, Jonna Storm; Jensen, Rigmor
2011-08-01
Once believed an exceedingly rare disorder, recent evidence suggests that low cerebrospinal fluid (CSF) pressure headache has to be considered an important cause of new daily persistent headaches, particularly among young and middle-aged individuals. Treatment of low CSF pressure headache consists of non-invasive/conservative measures and invasive measures with epidural blood patch providing the cornerstone of the invasive measures. In the present pilot study we therefore aimed to evaluate the treatment efficacy of epidural blood patch (EBP) in treatment-refractory low-pressure headache. Our primary effect parameter was total headache burden defined as area under the curve (AUC: intensity × duration) and as secondary effect parameters we identified: intensity (VAS 0-10), frequency (days per month), duration in hours (total hours/month) and also medication days (days on medication/month). In our primary effect parameter we found a significant reduction in AUC with more than 25% and this is considered to be clinically relevant. We found also a significant and relevant reduction at -22% in intensity. A trend towards reduction in duration was seen. We found no statistically significant reduction in frequency. An increase in days with use of medication was found. Increased awareness of low CSF pressure headache is emphasized and a controlled larger randomized study is needed to confirm the results. However the present results, allows us to conclude that EBP in treatment-refractory low CSF pressure headache can be considered as a treatment option.
Pressure-volume relationships and elastance in the knee joint of the dog.
Nade, S; Newbold, P J
1984-12-01
This study has investigated changes in intra-articular hydrostatic pressure in the knee joints of normal dogs in response to continuous and stepwise infusions of fluids. The relationship between pressure and volume in the joint was examined over the pressure range of -8 to +50 mmHg, and also at much higher pressures often associated with joint disease or injury. The effects of joint angle and dog weight on the pressure-volume relationship and on elastance of the dogs' knees were also examined. With liquid paraffin B.P. the pressure was found to increase more with each unit volume infused at subatmospheric pressures than at pressures around atmospheric, and increased more again at higher pressures. The pressure-volume curve with saline infusions was affected by egress of fluid from the joint at supra-atmospheric pressure. Above +5 mmHg the rise in pressure per unit volume infused was less than that for paraffin at the same volume. Elastance and compliance of the normal joint capsule were calculated from the pressure-volume data. Elastance was high at subatmospheric pressures, decreased rapidly as atmospheric pressure was approached and rose as a linear function of pressure above 12 mmHg. The biphasic shape of the elastance-pressure curve is discussed, and explanations for the shape are suggested. After intra-articular pressure in the knee was raised by infusion of paraffin oil the joint was moved through the range of positions from 125 deg extension to 50 deg flexion. Intra-articular pressure did not change across the range 125-110 deg. However, increasing the angle of flexion from 110 to 50 deg resulted in a rise in pressure which became steeper for each volume increment. Increasing intra-articular fluid volume caused a decrease in the total range of movement of the joint. The pressure-volume curves measured at extended angles of 110, 125 and 140 deg, where the starting pressures were subatmospheric, were the same. At flexed joint positions of 80 and 50 deg, where the starting pressures were supra-atmospheric, the pressure-volume curves became steeper with greater flexion. Elastance of the joint tissues increased with flexion. The elastance at each joint angle depended also on the volume or pressure. Significant differences were found to exist between pressure-volume curves for three groups of animals of different weight.(ABSTRACT TRUNCATED AT 400 WORDS)
Benetos, Athanase; Gautier, Sylvie; Labat, Carlos; Salvi, Paolo; Valbusa, Filippo; Marino, Francesca; Toulza, Olivier; Agnoletti, Davide; Zamboni, Mauro; Dubail, Delphine; Manckoundia, Patrick; Rolland, Yves; Hanon, Olivier; Perret-Guillaume, Christine; Lacolley, Patrick; Safar, Michel E; Guillemin, Francis
2012-10-16
The aim of the longitudinal PARTAGE study was to determine the predictive value of blood pressure (BP) and pulse pressure amplification, a marker of arterial function, for overall mortality (primary endpoint) and major cardiovascular (CV) events, in subjects older than 80 years of age living in a nursing home. Assessment of pulse indexes may be important in the evaluation of the CV risk in very elderly frail subjects. A total of 1,126 subjects (874 women) who were living in French and Italian nursing homes were enrolled (mean age, 88 ± 5 years). Central (carotid) to peripheral (brachial) pulse pressure amplification (PPA) was calculated with the help of an arterial tonometer. Clinical and 3-day self-measurements of BP were conducted. During the 2-year follow-up, 247 subjects died, and 228 experienced major CV events. The PPA was a predictor of total mortality and major CV events in this population. A 10% increase in PPA was associated with a 24% (p < 0.0003) decrease in total mortality and a 17% (p < 0.01) decrease in major CV events. Systolic BP, diastolic BP, or pulse pressure were either not associated or inversely correlated with total mortality and major CV events. In very elderly individuals living in nursing homes, low PPA from central to peripheral arteries strongly predicts mortality and adverse effects. Assessment of this parameter could help in risk estimation and improve diagnostic and therapeutic strategies in very old, polymedicated persons. In contrast, high BP is not associated with higher risk of mortality or major CV events in this population. (Predictive Values of Blood Pressure and Arterial Stiffness in Institutionalized Very Aged Population [PARTAGE]; NCT00901355). Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Kim, Seung-Hyun; Yu, Bo-Ra; Chung, Ill-Min
2015-06-01
This study investigated the changes in the contents and profiles of 35 phenolics (including 12 isoflavones), four tocopherols, two soyasapogenols and 20 amino acids when soybean and rice were cooked together (soybean-rice mixture) using either an electric rice cooker (ERC) or an electric pressure rice cooker (EPRC). The contents of the 35 selected phenolics in soybean decreased by 12% and 8% upon cooking by ERC and EPRC, respectively, and their profiles were different from that prior to cooking (P<0.05). Total tocopherol content of soybeans decreased by 7% after cooking in an ERC, but increased by 3% in soybeans cooked by EPRC. Total soyasapogenol content in soybeans cooked by ERC and EPRC decreased by 15% and 6%, respectively. Lastly, the total amino acid content of soybeans increased by 41% and 10% after cooking by ERC and EPRC, respectively. This study extends our knowledge about the effects of heat and pressure on the contents and profiles of bioactive compounds during soybean-rice mixture cooking. These results may be useful for improving the quality of bioactive compounds in soybean and rice depending on cooking conditions. Copyright © 2014 Elsevier Ltd. All rights reserved.
Ferreira, Rui R F; Gopegui, Rafael R; De Matos, Augusto J F
2015-03-01
There is no consensus regarding the blood volume that could be safely donated by dogs, ranging from 11 to 25% of its total blood volume (TBV). No previous studies evaluated sedated donors. To evaluate the hemodynamic effects of blood collection from sedated and non-sedated dogs and to understand if such effects were volume-dependent. Fifty three donations of 13% of TBV and 20 donations of 15% TBV were performed in dogs sedated with diazepam and ketamine. Additionally, a total of 30 collections of 13% TBV and 20 collections of 15% TBV were performed in non-sedated dogs. Non-invasive arterial blood pressures and pulse rates were registered before and 15 min after donation. Post-donation pulse rates increased significantly in both sedated groups, with higher differences in the 15% TBV collections. Systolic arterial pressures decreased significantly in these groups, while diastolic pressures increased significantly in 13% TBV donations. Non-sedated groups revealed a slight, but significant, SBP decrease. No clinical signs related to donations were registered. These results suggest that the collection of 15% TBV in sedated donors induces hemodynamic variations that may compromise the harmlessness of the procedure, while it seems to be a safe procedure in non-sedated dogs.
Carlsen, J E; Kardel, T; Hilden, T; Tangø, M; Trap-Jensen, J
1981-08-01
The purpose of this study was to evaluate the immediate central and peripheral haemodynamic effects of a new vasodilating agent P 1134, in hypertensive man. After oral administration of 25 mg P 1134, the maximal haemodynamic changes were (mean +/- 1 SEM): mean blood pressure fell from 121.8 +/- 6.5 to 80.5 +/- 7.8 mmHg, heart rate increased 24.2 +/- 4.5 beats/min, cardiac output rose 2.9 +/- 0.3 1/min and forearm blood flow increased 1.0 +/- 0.1 ml/100 ml tissue/min. Stroke volume increased 17.0 +/- 2.1 ml and the inotropic state of the heart as judged from systolic time intervals increased. Total peripheral resistance and forearm vascular resistance were both reduced by approx. 50%. Linear correlations were found between the serum concentration of P 1134 and the change in mean blood pressure and total peripheral resistance. Changes in the other parameters mentioned above occurred progressively with changes in mean blood pressure and total peripheral resistance. It can be concluded that P 1134 is a very potent hypotensive agent with a haemodynamic profile identical to that seen with vasodilators with preferably act on precapillary resistance vessels. Potency and maximal efficacy exceeds that of hydralazine and seems like that of minoxidil. P 1134 is remarkably free from side-effects apart from causing water retention as all other vasodilators. It can be administered orally as well as intravenously. This makes P 1134 a very interesting compound in the treatment of moderate to severe hypertension, and further studies are well-founded.
Single and two-phase flows of shear-thinning media in safety valves.
Moncalvo, D; Friedel, L
2009-09-15
This study is the first one in the scientific literature to investigate the liquid and two-phase flows of shear-thinning media, here aqueous solutions of polyvinylpyrrolidone, in a fully opened safety valve. In liquid flows the volume flux at the valve seat does not show any appreciable reduction when increasing the percental weight of polymer in the solution. This result may suggest that the viscous losses in the valve do not increase sensibly from the most aqueous to the most viscous solution. The authors explain it considering that in the region between the seat and the disk, where large pressure and velocity gradients occur, large shear rates are expected. On behalf of the rheological measurements, which show that both the pseudoplasticity and the zero-shear viscosity of the solutions increase with the polymer weight, the difference between the viscosities of the most viscous and those of the most aqueous solution is between the seat and the disk far less than that existing at zero-shear condition. Therefore, the effective viscous pressure drop of the safety valve, which occurs mostly in that region, must increase only modestly with the polymer percental weight in the solution. In two-phase flows the total mass flow rate at constant quality and constant relieving pressure increases remarkably with the polymer weight. The analogy with similar results in cocurrent pipe flows suggests that air entrainment causes large velocity gradients in the liquids and strains them to very large shear rates. It suggests also that a redistribution of the gas agglomerates within the liquid must be expected when increasing the polymer weight in the solutions. In fact, the gas agglomerates react to the larger viscous drag of the liquid by compressing their volume in order to exert a higher internal pressure. The reduction of the void fraction of the mixture at constant quality and constant relieving pressure imposes an increment in the total mass flow rate, since otherwise it would lead to a reduction in the momentum of the mixture and therefore to a drop in the relieving pressure.
Van Hemelrijck, Mieke; Ulmer, Hanno; Nagel, Gabriele; Peter, Raphael Simon; Fritz, Josef; Myte, Robin; van Guelpen, Bethany; Föger, Bernhard; Concin, Hans; Häggström, Christel; Stattin, Pär; Stocks, Tanja
2018-01-01
Obesity is suggested to underlie development of other metabolic aberrations, but longitudinal relationships between metabolic factors at various ages has not been studied in detail. Data from 27,379 men and 32,275 women with in total 122,940 health examinations in the Västerbotten Intervention Project, Sweden and the Vorarlberg Health Monitoring and Prevention Programme, Austria were used to investigate body mass index (BMI), mid-blood pressure, and fasting levels of glucose, triglycerides, and total cholesterol at baseline in relation to 10-year changes of these factors and weight. We included paired examinations performed 10±2 years apart and used them for longitudinal analysis with linear regression of changes between the ages 30 and 40, 40 and 50, or 50 and 60 years. Higher levels of BMI were associated with increases in glucose and mid-blood pressure as well as triglycerides levels, and, to a lesser extent, decreases in cholesterol levels. For instance, per 5 kg/m2 higher BMI at age 40, glucose at age 50 increased by 0.24 mmol/l (95%CI: 0.22-0.26) and mid-blood pressure increased by 1.54 mm Hg (95%CI: 1.35-1.74). The strongest association observed was between BMI at age 30 and mid-blood pressure, which was 2.12 mm Hg (95% CI: 1.79-2.45) increase over ten years per 5 kg/m2 higher BMI level. This association was observed at an age when blood pressure levels on average remained stable. Other associations than those with BMI at baseline were much weaker. However, triglyceride levels were associated with future glucose changes among individuals with elevated BMI, particularly in the two older age groups. BMI was most indicative of long-term changes in metabolic factors, and the strongest impact was observed for increases in blood pressure between 30 and 40 years of age. Our study supports that lifestyle interventions preventing metabolic aberrations should focus on avoiding weight increases.
Yang, Jian-min; Lu, Fang-hong; Jin, Shi-kuan; Sun, Shang-wen; Zhao, Ying-xin; Wang, Shu-jian; Zhou, Xiao-hong
2007-02-01
To explore the factors influencing cardio-cerebro vascular death events among people over 40 years of age in Shandong area, China. Baseline survey was carried out in 1991. A total number of 11,008 adults over 40 years old had been studied in Shandong province. Data on cardiocerebro death was collected. The correlation between influencing factors and cardio-cerebro vascular death events was analyzed by Cox regression model. Totally, 434 cardio-cerebro death events occurred among the 11,008 subjects during the 8-year follow-up study. Cardio-cerebro death events were related to systolic blood pressure, diastolic blood pressure, smoking, stroke history and age. Data from Cox regression analysis showed that the relative risk (RR) for cardio-cerebro vascular death events increased by 2.862 [95% confidence interval (CI): 1.976-4.144] times for those people having stroke history. When systolic blood pressure, diastolic blood pressure increased by every 10 mm Hg, the relative risk for cardio-cerebro vascular death events increased by 1.171 (95% CI: 1.033-1.328), 1.214 (95% CI: 1.044-1.413) respectively. it was found that a 1.239 (95% CI: 1.088-1.553) times higher in smokers than non-smokers on relative risk for cardio-cerebro vascular death events. However, the predictive values of the influencing factors for cardio-cerebro vascular death were different among population of different years of age. The relative risk for cardio-cerebro vascular death events increased by 1.366 (95% CI: 1.102-1.678) times for each 10 mm Hg increase of diastolic blood pressure in 40-59 years old population. However, the effect was taken place by systolic blood pressure in 60-74 years old population,with a relative risk of 1.201 (95% CI: 1.017-1.418) for each 10 mm Hg increase. Age seemed the only significant factor for cardio-cerebro vascular death events on population aged more than 75 years old. Conclusion The predictive values of the risk factors were different among age groups. The different risk factors should be taken care according to the difference of age.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Diallo, S. O.; Zhang, Q.; O'Neill, H.
Here we present a pressure-dependence study of the dynamics of lysozyme protein powder immersed in deuterated , α-trehalose environment via quasielastic neutron scattering (QENS). The goal is to assess the baroprotective benefits of trehalose on biomolecules by comparing the findings with those of a trehalose-free reference study. While the mean-square displacement of the trehalose-free protein (hydrated to d D₂O ≃40 w%) as a whole, is reduced by increasing pressure, the actual observable relaxation dynamics in the picoseconds to nanoseconds time range remains largely unaffected by pressure up to the maximum investigated pressure of 2.78(2) Kbar. Our observation is independent ofmore » whether or not the protein is mixed with the deuterated sugar. This suggests that the hydrated protein s conformational states at atmospheric pressure remain unaltered by hydrostatic pressures, below 2.78 Kbar. We also found the QENS response to be totally recoverable after ambient pressure conditions are restored. Small-angle neutron diffraction measurements confirm that the protein-protein correlation remains undisturbed.We observe, however, a clear narrowing of the QENS response as the temperature is decreased from 290 to 230 K in both cases, which we parametrize using the Kohlrausch-Williams-Watts stretched exponential model. Finally, only the fraction of protons that are immobile on the accessible time window of the instrument, referred to as the elastic incoherent structure factor, is observably sensitive to pressure, increasing only marginally but systematically with increasing pressure.« less
Lim, Wai-Yee; Chong, Mary; Calder, Philip C; Kwek, Kenneth; Chong, Yap-Seng; Gluckman, Peter D; Godfrey, Keith M; Saw, Seang-Mei; Pan, An
2015-03-01
Observational and intervention studies have reported inconsistent results of the relationship between polyunsaturated fatty acids (PUFAs) and hypertension during pregnancy. Here, we examined maternal plasma concentrations of n-3 and n-6 PUFAs between the 26th and the 28th week of gestation in relation to blood pressures and pregnancy-associated hypertension.We used data from a birth cohort study of 751 Chinese, Malay, and Indian women. Maternal peripheral systolic blood pressure (SBP) and diastolic blood pressure (DBP) were taken from the brachial arm, and central SBP and pulse pressures (PPs) were derived from radial artery pressure waveforms between the 26th and the 28th week of gestation. Pregnancy-associated hypertension (including gestational hypertension and preeclampsia) was ascertained from medical records. Plasma phosphatidylcholine n-3 and n-6 PUFAs were measured by gas chromatography and expressed as percentage of total fatty acids.Peripheral SBP was inversely associated with total n-3 PUFAs [-0.51 (95% confidence interval, CI, -0.89 to -0.13) mm Hg] and long-chain n-3 PUFAs [-0.52 (CI -0.92 to -0.13) mmHg]. Similar but weaker associations were observed for central SBP and PP. Dihomo-γ-linolenic acid was marginally positively associated with peripheral SBP, central SBP, and PP, whereas linoleic acid and total n-6 PUFAs showed no significant associations with blood pressures. We identified 28 pregnancy-associated hypertension cases, and 1% increase in total n-3 PUFAs was associated with a 24% lower odds of pregnancy-associated hypertension (odds ratio 0.76; 95% CI 0.60 to 0.97). Maternal ethnicity modified the PUFAs-blood pressure relations, with stronger inverse associations with n-3 PUFAs in Chinese women, and stronger positive associations with n-6 PUFAs in Indian women (P values for interaction ranged from 0.02 to 0.07).Higher n-3 PUFAs at midgestation are related to lower maternal blood pressures and pregnancy-associated hypertension in Asian women, and the ethnicity-related variation between PUFAs and blood pressures deserves further investigation.
Lim, Wai-Yee; Chong, Mary; Calder, Philip C.; Kwek, Kenneth; Chong, Yap-Seng; Gluckman, Peter D.; Godfrey, Keith M.; Saw, Seang-Mei; Pan, An
2015-01-01
Abstract Observational and intervention studies have reported inconsistent results of the relationship between polyunsaturated fatty acids (PUFAs) and hypertension during pregnancy. Here, we examined maternal plasma concentrations of n-3 and n-6 PUFAs between the 26th and the 28th week of gestation in relation to blood pressures and pregnancy-associated hypertension. We used data from a birth cohort study of 751 Chinese, Malay, and Indian women. Maternal peripheral systolic blood pressure (SBP) and diastolic blood pressure (DBP) were taken from the brachial arm, and central SBP and pulse pressures (PPs) were derived from radial artery pressure waveforms between the 26th and the 28th week of gestation. Pregnancy-associated hypertension (including gestational hypertension and preeclampsia) was ascertained from medical records. Plasma phosphatidylcholine n-3 and n-6 PUFAs were measured by gas chromatography and expressed as percentage of total fatty acids. Peripheral SBP was inversely associated with total n-3 PUFAs [−0.51 (95% confidence interval, CI, −0.89 to −0.13) mm Hg] and long-chain n-3 PUFAs [−0.52 (CI −0.92 to −0.13) mmHg]. Similar but weaker associations were observed for central SBP and PP. Dihomo-γ-linolenic acid was marginally positively associated with peripheral SBP, central SBP, and PP, whereas linoleic acid and total n-6 PUFAs showed no significant associations with blood pressures. We identified 28 pregnancy-associated hypertension cases, and 1% increase in total n-3 PUFAs was associated with a 24% lower odds of pregnancy-associated hypertension (odds ratio 0.76; 95% CI 0.60 to 0.97). Maternal ethnicity modified the PUFAs–blood pressure relations, with stronger inverse associations with n-3 PUFAs in Chinese women, and stronger positive associations with n-6 PUFAs in Indian women (P values for interaction ranged from 0.02 to 0.07). Higher n-3 PUFAs at midgestation are related to lower maternal blood pressures and pregnancy-associated hypertension in Asian women, and the ethnicity-related variation between PUFAs and blood pressures deserves further investigation. PMID:25738474
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chick, Lawrence A.; Marina, Olga A.; Coyle, Christopher A.
2013-08-15
A button solid oxide fuel cell with a La0.6Sr0.4Co0.2Fe0.8O3 cathode and a nickel-YSZ anode was tested over a range of temperatures from 650 to 800°C and a range of pressures from 101 to 724 kPa. The fuel was simulated steam-reformed kerosene and the oxidant was air. The observed increases in open circuit voltages (OCV) were accurately predicted by the Nernst equation. Kinetics also increased, although the power boost due to kinetics was about two thirds as large as the boost due to OCV. The total power boost in going from 101 to 724 kPa at 750°C and 0.8 volts wasmore » 66%. Impedance spectroscopy demonstrated a significant decrease in electrodic losses at elevated pressures. Complex impedance spectra were dominated by a combination of low frequency processes that decreased markedly with increasing pressure. A composite of high-frequency processes also decreased with pressure, but to a lesser extent. An empirical algorithm that accurately predicts the increased fuel cell performance at elevated pressures was developed for our results and was also suitable for some, but not all, data reported in the literature.« less
Chopski, Steven G; Rangus, Owen M; Moskowitz, William B; Throckmorton, Amy L
2014-09-01
A mechanical blood pump specifically designed to increase pressure in the great veins would improve hemodynamic stability in adolescent and adult Fontan patients having dysfunctional cavopulmonary circulation. This study investigates the impact of axial-flow blood pumps on pressure, flow rate, and energy augmentation in the total cavopulmonary circulation (TCPC) using a patient-specific Fontan model. The experiments were conducted for three mechanical support configurations, which included an axial-flow impeller alone in the inferior vena cava (IVC) and an impeller with one of two different protective stent designs. All of the pump configurations led to an increase in pressure generation and flow in the Fontan circuit. The increase in IVC flow was found to augment pulmonary arterial flow, having only a small impact on the pressure and flow in the superior vena cava (SVC). Retrograde flow was neither observed nor measured from the TCPC junction into the SVC. All of the pump configurations enhanced the rate of power gain of the cavopulmonary circulation by adding energy and rotational force to the fluid flow. We measured an enhancement of forward flow into the TCPC junction, reduction in IVC pressure, and only minimally increased pulmonary arterial pressure under conditions of pump support. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Hemley, J.J.; Cygan, G.L.; Fein, J.B.; Robinson, G.R.; d'Angelo, W. M.
1992-01-01
Experimental studies, using cold-seal and extraction vessel techniques, were conducted on Fe, Pb, Zn, and Cu sulfide solubilities in chloride soultions at temperatures from 300?? to 700??C and pressures from 0.5 to 2 kbars. The solutions were buffered in pH by quartz monzonite and the pure potassium feldspar-muscovite-quartz assemblage and in fS2-fO2 largely by the assemblage pyrite-pyrrhotite-magnetite. Solubilities increase with increasing temperature and total chloride, and decrease with increasing pressure. The effect of increasing chloride concentration on solubility reflects primarily a shift to lower pH via the silicate buffer reactions. Similarity in behaviour with respect to the temperature and pressure of Fe, Zn, and Pb sulfide solubilities points to similarity in chloride speciation, and the neutral species appear to be dominant in the high-temperature region. -from Authors
NASA Astrophysics Data System (ADS)
Yin, Zhu-Hua; Zhang, Jian-Min
2016-10-01
The structural stability, electronic, magnetic and optical properties of zincblende Zn0.5V0.5Te under pressures 0-5 GPa are investigated by the spin-polarized first-principles calculation. Under pressure, the Zn0.5V0.5Te is always half-metal with the total magnetic moment μtot of 3μB / cell mainly contributed by V2+ ion, but the spin-down channel opens a band gap. The Zn0.5V0.5Te also behaves in a ductile manner and is mechanical stable until 3.78 GPa pressure. The static dielectric function ε1 (0) and refractive index n (0) increase with pressure. The two absorption peaks located in energy regions 0-20 eV and 35-50 eV not only increase but also shift to the higher energy region (blue shift) with pressure. So the electronic and optical properties of Zn0.5V0.5Te could be tuned through external pressure, which is beneficial to the electronic and optical applications.
Plantar Loading During Cutting While Wearing a Rigid Carbon Fiber Insert.
Queen, Robin M; Abbey, Alicia N; Verma, Ravi; Butler, Robert J; Nunley, James A
2014-02-12
Context : Stress fractures are one of the most common injuries in sports, accounting for approximately 10% of all overuse injuries. Treatment of fifth metatarsal stress fractures involves both surgical and nonsurgical interventions. Fifth metatarsal stress fractures are difficult to treat because of the risks of delayed union, nonunion, and recurrent injuries. Most of these injuries occur during agility tasks, such as those performed in soccer, basketball, and lacrosse. Objective : To examine the effect of a rigid carbon graphite footplate on plantar loading during 2 agility tasks. Design : Crossover study. Setting : Laboratory. Patients or Other Participants : A total of 19 recreational male athletes with no history of lower extremity injury in the past 6 months and no previous metatarsal stress fractures were tested. Main Outcome Measure(s) : Seven 45° side-cut and crossover-cut tasks were completed in a shoe with or without a full-length rigid carbon plate. Testing order between the shoe conditions and the 2 cutting tasks was randomized. Plantar-loading data were recorded using instrumented insoles. Peak pressure, maximum force, force-time integral, and contact area beneath the total foot, the medial and lateral midfoot, and the medial, middle, and lateral forefoot were analyzed. A series of paired t tests was used to examine differences between the footwear conditions (carbon graphite footplate, shod) for both cutting tasks independently (α = .05). Results : During the side-cut task, the footplate increased total foot and lateral midfoot peak pressures while decreasing contact area and lateral midfoot force-time integral. During the crossover-cut task, the footplate increased total foot and lateral midfoot peak pressure and lateral forefoot force-time integral while decreasing total and lateral forefoot contact area. Conclusions : Although a rigid carbon graphite footplate altered some aspects of the plantar- pressure profile during cutting in uninjured participants, it was ineffective in reducing plantar loading beneath the fifth metatarsal.
Plantar Loading During Cutting While Wearing a Rigid Carbon Fiber Insert
Queen, Robin M.; Abbey, Alicia N.; Verma, Ravi; Butler, Robert J.; Nunley, James A.
2014-01-01
Context Stress fractures are one of the most common injuries in sports, accounting for approximately 10% of all overuse injuries. Treatment of fifth metatarsal stress fractures involves both surgical and nonsurgical interventions. Fifth metatarsal stress fractures are difficult to treat because of the risks of delayed union, nonunion, and recurrent injuries. Most of these injuries occur during agility tasks, such as those performed in soccer, basketball, and lacrosse. Objective: To examine the effect of a rigid carbon graphite footplate on plantar loading during 2 agility tasks. Design: Crossover study. Setting: Laboratory. Patients or Other Participants: A total of 19 recreational male athletes with no history of lower extremity injury in the past 6 months and no previous metatarsal stress fractures were tested. Main Outcome Measure(s): Seven 45° side-cut and crossover-cut tasks were completed in a shoe with or without a full-length rigid carbon plate. Testing order between the shoe conditions and the 2 cutting tasks was randomized. Plantar-loading data were recorded using instrumented insoles. Peak pressure, maximum force, force-time integral, and contact area beneath the total foot, the medial and lateral midfoot, and the medial, middle, and lateral forefoot were analyzed. A series of paired t tests was used to examine differences between the footwear conditions (carbon graphite footplate, shod) for both cutting tasks independently (α = .05). Results: During the side-cut task, the footplate increased total foot and lateral midfoot peak pressures while decreasing contact area and lateral midfoot force-time integral. During the crossover-cut task, the footplate increased total foot and lateral midfoot peak pressure and lateral forefoot force-time integral while decreasing total and lateral forefoot contact area. Conclusions: Although a rigid carbon graphite footplate altered some aspects of the plantar-pressure profile during cutting in uninjured participants, it was ineffective in reducing plantar loading beneath the fifth metatarsal. PMID:24955620
Preliminary Data on the Effects of Inlet Pressure Distortions on the J57-P-1 Turbojet Engine
NASA Technical Reports Server (NTRS)
Wallner, Lewis E.; Lubick, Robert J.; Einstein, Thomas H.
1954-01-01
An investigation to determine the steady-state and surge characteristics of the J57-P-1 two-spool turbojet engine with various inlet air-flow distortions was conducted in the altitude wind tunnel at the NACA Lewis laboratory. Along with a uniform inlet total-pressure distribution, one circumferential and three radial pressure distortions were investigated. Data were obtained over a complete range of compressor speeds both with and without intercompressor air bleed at a flight Mach number of 0.8 and at altitudes of 35,000 and 50,000 feet. Total-pressure distortions of the magnitudes investigated had very little effect on the steady-state operating line for either the outer or inner compressor. The small radial distortions investigated also had engine over that obtained with the uniform inlet pressure distribution. The circumferential distortion, however, raised the minimum speed at which the engine could operate without encountering surge when the intercompressor bleeds were closed. This increase in minimum speed resulted in a substantial reduction in the operable speed range accompanied by a reduction in the altitude operating limit.
Cao, Baiying; Fang, Li; Liu, Chunlei; Min, Weihong; Liu, Jingsheng
2018-01-01
High hydrostatic pressure treatments could increase the protein solubility (200 MPa), water holding capacity (400 MPa), and oil holding capacity (400 MPa) of pine nuts protein fractions, respectively. The exposed sufhydryl content for albumin was highest at 100 MPa while for other fractions it was 400 MPa, contrary for total sufhydryl content-generally it was at 100 MPa, except glutelin (400 MPa). Pine nuts protein fractions demonstrated the typical behavior of weak gels (G' > G″). After the treatments of high hydrostatic pressure the specific surface area of pine nuts protein particle was increased upon pressure, and the surface of protein became rough which increased the particle size. The functional groups of protein were found to be unchanged, but the characteristic peaks of pine nuts protein moved to a low-band displacement and the value of peaks was amplified accordingly to the pressure. The high hydrostatic pressure treatments were found to improve the functional properties of pine nuts protein isolates by enhancing the heat-induced gel strength of pine nuts protein isolates which make proteins more stretchable. These results suggest that high hydrostatic pressure treatments can increase the functional properties and alter the rheological properties of pine nuts protein fractions which will broaden its applications in food industry.
Casado Cerrada, Jesús; Parra Caballero, Pedro; Vega Piris, Lorena; Suárez Fernández, Carmen
2013-10-05
Vitamin D deficiency and parathyroid hormone (PTH) are associated with an increased cardiovascular risk and arterial stiffness. The aim of our study is to compare the cardiovascular risk in subjects with low vitamin D, attending to the PTH concentration, as well as evaluating the response after administration of vitamin D. Prospective study of patients with a concentration of 25(OH)-vitamin D below 30nmol/l. We evaluated vascular risk parameters as blood pressure, arterial stiffness, lipid profile and glucose metabolism. Patients received vitamin D supplements for 3 months, after which the previous parameters were reassessed. A total of 32 patients were included. Those with PTH over 65pg/ml were older, had worse renal function, higher systolic blood pressure, pulse pressure and arterial stiffness. Treatment with vitamin D showed a statistically significant trend to lower blood pressure and pulse wave velocity. The increase in PTH in patients with low vitamin D involves poor control of blood pressure and increased vascular stiffness. Vitamin D replacement shows a tendency to reduce these parameters. Copyright © 2012 Elsevier España, S.L. All rights reserved.
Kjeldsen, Sverre E; Knudsen, Karl; Ekrem, Gunhild; Fure, Tormod O; Movinckel, Petter; Erikssen, Jan E
2006-01-01
Job strain may be associated with various diseases and increased mortality but there is little data available from prospective studies with long-term follow-up. To assess the effect of heat exposure followed by severe job strain on blood pressure, heart rate and mortality. Prospective 19-year observational study (1982-2000) of a cohort of employees in a ferry alloy plant undergoing two economical crises. The participants were 218 healthy males aged 30-59 years. Annual standardized measurements of blood pressure, heart rate, serum cholesterol and registration of morbidity and mortality. Heat-exposed men (n = 25) and non-heat-exposed men (n = 193) had unchanged blood pressure from 1982 to 1984. Thereafter the plant underwent two serious economic crises, in 1985-87 and 1990-91, respectively. The first one was handled by decisions exclusively taken by the head office and included a gradual lay-off of 25% of the workers, and the second one was handled jointly between the local management, union leaders and employees and included a modest, voluntary lay-off. Thus, the two crises differed markedly in low vs high job control. Blood pressures gradually increased from 1985 to 1988 in the whole cohort until systolic blood pressure reached 15 mmHg and diastolic blood pressure 12 mmHg above baseline levels (p < 0.001). Thereafter blood pressures decreased to slightly above baseline levels and then remained unchanged for the next 5 years. However, heart rate increased from 62 +/- 12 beats/min in 1982-83 to 69 +/- 10 beats/min in 1988 (p < 0.01) and did not return to baseline. Total mortality by 31 December 2000 in the study cohort was significantly higher over the 19 years of follow-up than among age-matched, Norwegian men (p < 0.01). If a cause-effect relationship exists between the first economical crisis in the ferry alloy plant and the concomitant rise in blood pressure, job strain had a powerful but time-limited effect on blood pressure. Since the same phenomenon was not reproduced 5 years later, the marked difference in job control (high vs low) may constitute the difference. Alternatively, age-related effects or adaptive coping mechanisms may have prevented a similar second blood pressure rise despite exposure to a job strain of similar severity. However, there was also a high 19-year total mortality in the study population, which could be related to long-term health consequences of the first or both economic crises. This study provides some support for the notion that increased job strain elevates blood pressure and deteriorates outcome.
NASA Technical Reports Server (NTRS)
Berdanier, Reid A.; Key, Nicole L.
2015-01-01
The focus of this work was to characterize the fundamental flow physics and the overall performance effects due to increased rotor tip clearance heights in axial compressors. Data have been collected in the three-stage axial research compressor at Purdue University with a specific focus on analyzing the multistage effects resulting from the tip leakage flow. Three separate rotor tip clearance heights were studied with nominal tip clearance heights of 1.5%, 3.0%, and 4.0% based on a constant annulus height. Overall compressor performance was investigated at four corrected speedlines (100%, 90%, 80%, and 68%) for each of the three tip clearance configurations using total pressure and total temperature rakes distributed throughout the compressor. The results have confirmed results from previous authors showing a decrease of total pressure rise, isentropic efficiency, and stall margin which is approximately linear with increasing tip clearance height. The stall inception mechanisms have also been evaluated at the same corrected speeds for each of the tip clearance configurations. Detailed flow field measurements have been collected at two loading conditions, nominal loading (NL) and high loading (HL), on the 100% corrected speedline for the smallest and largest tip clearance heights (1.5% and 4.0%). Steady detailed radial traverses of total pressure at the exit of each stator row have been supported by flow visualization techniques to identify regions of flow recirculation and separation. Furthermore, detailed radial traverses of time-resolved total pressures at the exit of each rotor row have been measured with a fast-response pressure probe. These data have helped to quantify the size of the leakage flow at the exit of each rotor. Thermal anemometry has also been implemented to evaluate the time-resolved three-dimensional components of velocity throughout the compressor and calculate blockage due to the rotor tip leakage flow throughout the compressor. These measurements have also been used to calculate streamwise vorticity. Time-resolved static pressure measurements have been collected over the rotor tips for all rotors with each of the three tip clearance configurations for up to five loading conditions along the 100% corrected speedline using fast-response piezoresistive pressure sensors. These time-resolved static pressure measurements, as well as the time-resolved total pressures and velocities have helped to reveal a profound influence of the upstream stator vane on the size and shape of the rotor tip leakage flow. Finally, a novel particle image velocimetry (PIV) technique has been developed as a proof-of- concept. In contrast to PIV methods that have been typically been utilized for turbomachinery applications in the past, the method used for this study introduced the laser light through the same access window that was also used to image the flow. This new method addresses potential concerns related to the intrusive laser-introducing techniques that have typically been utilized by other authors in the past. Ultimately, the data collected for this project represent a unique data set which contributes to build a better understanding of the tip leakage flow field and its associated loss mechanisms. These data will facilitate future engine design goals leading to small blade heights in the rear stages of high pressure compressors and aid in the development of new blade designs which are desensitized to the performance penalties attributed to rotor tip leakage flows.
Fattore, Elena; Botta, Francesca; Agostoni, Carlo; Bosetti, Cristina
2017-01-01
Sugar has been suggested as a central risk factor in the development of noncommunicable diseases. We assessed the evidence of the effects of free sugars compared with complex carbohydrates on selected cardiovascular disease risk factors. We conducted a systematic review and meta-analysis of intervention trials to compare diets that provide a given amount of energy from free sugars with a control diet that provides the same amount of energy from complex carbohydrates. The primary outcomes were: blood pressure, total cholesterol, low-density lipoprotein (LDL) cholesterol, high-density lipoprotein (HDL) cholesterol, triacylglycerols, apolipoproteins A-I and B, or very low-density lipoprotein cholesterol. Body weight was also recorded but was not a primary outcome of the studies. In all, 28 studies involving 510 volunteers were included. When free sugars were substituted for complex carbohydrates, no significant increases were detected in systolic or diastolic blood pressure, and no heterogeneity was observed. There were significant increases in HDL cholesterol, LDL cholesterol, and triacylglycerols, although for LDL cholesterol and triacylglycerols there was significant heterogeneity between studies and evidence of publication bias. After adjustment for missing studies, these increases lost significance. Subgroup analyses showed that diets providing the largest total energy intake and energy exchange enhanced the effect of free sugars on total and LDL cholesterol and triacylglycerols. The increase of triacylglycerols was no longer significant when studies with the highest risk of bias were excluded or when only randomized trials were considered. Free sugars had no effect on body weight. In short- or moderate-term isoenergetic intervention trials, the substitution of free sugars for complex carbohydrates had no effect on blood pressure or body weight and an unclear effect on blood lipid profile. Further independent trials are required to assess whether the reduction of free sugars improves cardiovascular disease risk factors. This review was registered at http://www.crd.york.ac.uk/prospero as CRD42016042930. © 2017 American Society for Nutrition.
Drinking carrot juice increases total antioxidant status and decreases lipid peroxidation in adults.
Potter, Andrew S; Foroudi, Shahrzad; Stamatikos, Alexis; Patil, Bhimanagouda S; Deyhim, Farzad
2011-09-24
High prevalence of obesity and cardiovascular disease is attributable to sedentary lifestyle and eating diets high in fat and refined carbohydrate while eating diets low in fruit and vegetables. Epidemiological studies have confirmed a strong association between eating diets rich in fruits and vegetables and cardiovascular health. The aim of this pilot study was to determine whether drinking fresh carrot juice influences antioxidant status and cardiovascular risk markers in subjects not modifying their eating habits. An experiment was conducted to evaluate the effects of consuming 16 fl oz of daily freshly squeezed carrot juice for three months on cardiovascular risk markers, C-reactive protein, insulin, leptin, interleukin-1α, body fat percentage, body mass index (BMI), blood pressure, antioxidant status, and malondialdehyde production. Fasting blood samples were collected pre-test and 90 days afterward to conclude the study. Drinking carrot juice did not affect (P > 0.1) the plasma cholesterol, triglycerides, Apo A, Apo B, LDL, HDL, body fat percentage, insulin, leptin, interleukin-1α, or C-reactive protein. Drinking carrot juice decreased (P = 0.06) systolic pressure, but did not influence diastolic pressure. Drinking carrot juice significantly (P < 0.05) increased the plasma total antioxidant capacity and decreased (P < 0.05) the plasma malondialdehyde production. Drinking carrot juice may protect the cardiovascular system by increasing total antioxidant status and by decreasing lipid peroxidation independent of any of the cardiovascular risk markers measured in the study.
Lucato, Jeanette Janaina Jaber; Cunha, Thiago Marraccini Nogueira da; Reis, Aline Mela Dos; Picanço, Patricia Salerno de Almeida; Barbosa, Renata Cléia Claudino; Liberali, Joyce; Righetti, Renato Fraga
2017-01-01
To evaluate the possible changes in tidal volume, minute volume and respiratory rate caused by the use of a heat and moisture exchanger in patients receiving pressure support mechanical ventilation and to quantify the variation in pressure support required to compensate for the effect caused by the heat and moisture exchanger. Patients under invasive mechanical ventilation in pressure support mode were evaluated using heated humidifiers and heat and moisture exchangers. If the volume found using the heat and moisture exchangers was lower than that found with the heated humidifier, an increase in pressure support was initiated during the use of the heat and moisture exchanger until a pressure support value was obtained that enabled the patient to generate a value close to the initial tidal volume obtained with the heated humidifier. The analysis was performed by means of the paired t test, and incremental values were expressed as percentages of increase required. A total of 26 patients were evaluated. The use of heat and moisture exchangers increased the respiratory rate and reduced the tidal and minute volumes compared with the use of the heated humidifier. Patients required a 38.13% increase in pressure support to maintain previous volumes when using the heat and moisture exchanger. The heat and moisture exchanger changed the tidal and minute volumes and respiratory rate parameters. Pressure support was increased to compensate for these changes.
Lucato, Jeanette Janaina Jaber; da Cunha, Thiago Marraccini Nogueira; dos Reis, Aline Mela; Picanço, Patricia Salerno de Almeida; Barbosa, Renata Cléia Claudino; Liberali, Joyce; Righetti, Renato Fraga
2017-01-01
Objective To evaluate the possible changes in tidal volume, minute volume and respiratory rate caused by the use of a heat and moisture exchanger in patients receiving pressure support mechanical ventilation and to quantify the variation in pressure support required to compensate for the effect caused by the heat and moisture exchanger. Methods Patients under invasive mechanical ventilation in pressure support mode were evaluated using heated humidifiers and heat and moisture exchangers. If the volume found using the heat and moisture exchangers was lower than that found with the heated humidifier, an increase in pressure support was initiated during the use of the heat and moisture exchanger until a pressure support value was obtained that enabled the patient to generate a value close to the initial tidal volume obtained with the heated humidifier. The analysis was performed by means of the paired t test, and incremental values were expressed as percentages of increase required. Results A total of 26 patients were evaluated. The use of heat and moisture exchangers increased the respiratory rate and reduced the tidal and minute volumes compared with the use of the heated humidifier. Patients required a 38.13% increase in pressure support to maintain previous volumes when using the heat and moisture exchanger. Conclusion The heat and moisture exchanger changed the tidal and minute volumes and respiratory rate parameters. Pressure support was increased to compensate for these changes. PMID:28977257
Anesthetic management of the SRS™ Endoscopic Stapling System for gastro-esophageal reflux disease.
Topuz, Ufuk; Umutoglu, Tarik; Bakan, Mefkur; Ozturk, Erdogan
2013-01-14
The SRS(TM) Endoscopic Stapling System (Medigus, Tel Aviv, Israel) is a new tool capable of creating a totally endoscopic fundoplication, combined with an endoscope, endoscopic ultrasound and a surgical stapler. SRS(TM) endoscopic stapling for gastro-esophageal reflux disease is a minimally invasive, outpatient procedure, which requires general anesthesia with positive-pressure ventilation. Keeping the patient on positive end-expiratory pressure (PEEP) may minimize the pressure gradient between the esophagus and the mediastinum, as well as help to prevent air from leaking around the screws and causing pneumomediastinum. In addition, in patients with hiatal hernia, higher PEEP levels may be required to increase intra-thoracic pressure and to force the stomach to slide into the abdomen for ease of endoscopy. We advise smoother emergence from anesthesia, taking precautions for retching, postoperative nausea and vomiting (PONV), while coughing and gagging during extubation and PONV may affect the success of the procedure. Total intravenous anesthesia with propofol and remifentanil seems to be a good choice for these reasons.
Measurement and analysis of a small nozzle plume in vacuum
NASA Technical Reports Server (NTRS)
Penko, P. F.; Boyd, I. D.; Meissner, D. L.; Dewitt, K. J.
1993-01-01
Pitot pressures and flow angles are measured in the plume of a nozzle flowing nitrogen and exhausting to a vacuum. Total pressures are measured with Pitot tubes sized for specific regions of the plume and flow angles measured with a conical probe. The measurement area for total pressure extends 480 mm (16 exit diameters) downstream of the nozzle exit plane and radially to 60 mm (1.9 exit diameters) off the plume axis. The measurement area for flow angle extends to 160 mm (5 exit diameters) downstream and radially to 60 mm. The measurements are compared to results from a numerical simulation of the flow that is based on kinetic theory and uses the direct-simulation Monte Carlo (DSMC) method. Comparisons of computed results from the DSMC method with measurements of flow angle display good agreement in the far-field of the plume and improve with increasing distance from the exit plane. Pitot pressures computed from the DSMC method are in reasonably good agreement with experimental results over the entire measurement area.
NASA Technical Reports Server (NTRS)
Williams, M.; Harris, W. L.
1984-01-01
The purpose of the analysis is to determine if inflow turbulence distortion may be a cause of experimentally observed changes in sound pressure levels when the rotor mean loading is varied. The effect of helicopter rotor mean aerodynamics on inflow turbulence is studied within the framework of the turbulence rapid distortion theory developed by Pearson (1959) and Deissler (1961). The distorted inflow turbulence is related to the resultant noise by conventional broadband noise theory. A comparison of the distortion model with experimental data shows that the theoretical model is unable to totally explain observed increases in model rotor sound pressures with increased rotor mean thrust. Comparison of full scale rotor data with the theoretical model shows that a shear-type distortion may explain decreasing sound pressure levels with increasing thrust.
Mechanical Anisotropic and Electronic Properties of Amm2-carbon under Pressure*
NASA Astrophysics Data System (ADS)
Xing, Meng-Jiang; Li, Xiao-Zhen; Yu, Shao-Jun; Wang, Fu-Yan
2017-09-01
Structural, electronic properties and mechanical anisotropy of Amm2-carbon are investigated utilizing frist-principles calculations by Cambridge Serial Total Energy Package (CASTEP) code. The work is performed with the generalized gradient approximation in the form of Perdew-Burke-Ernzerhof (PBE), PBEsol, Wu and Cohen (WC) and local density approximation in the form of Ceperley and Alder data as parameterized by Perdew and Zunger (CA-PZ). The mechanical anisotropy calculations show that Amm2-carbon exhibit large anisotropy in elastic moduli, such as Poisson’s ratio, shear modulus and Young’s modulus, and other anisotropy factors, such as the shear anisotropic factor and the universal anisotropic index AU. It is interestingly that the anisotropy in shear modulus and Young’s modulus, universal anisotropic index and the shear anisotropic factor all increases with increasing pressure, but the anisotropy in Poisson’s ratio decreases. The band structure calculations reveal that Amm2-carbon is a direct-band-gap semiconductor at ambient pressure, but with the pressure increasing, it becomes an indirect-band-gap semiconductor.
Pollutant emissions from flat-flame burners at high pressures
NASA Technical Reports Server (NTRS)
Maahs, H. G.; Miller, I. M.
1980-01-01
Maximum flame temperatures and pollutant emission measurements for NOx, CO, and UHC (unburned hydrocarbons) are reported for premixed methane air flat flames at constant total mass flow rate over the pressure range from 1.9 to 30 atm and for equivalence ratios from 0.84 to 1.12. For any given pressure, maxima typically occur in both the temperature and NOx emissions curves slightly to the lean side of stoichiometric conditions. The UHC emissions show minima at roughly the same equivalence ratios. The CO emissions, however, increase continually with increasing equivalence ratio. Flame temperature and NOx emissions decrease with increasing pressure, while the opposite is true for the CO and UHC emissions. The NOx data correlate reasonably well as a function of flame temperature only. Four flameholders, differing only slightly, were used. In general, the temperature and emissions data from these four flameholders are similar, but some differences also exist. These differences appear to be related to minor variations in the condition of the flameholder surfaces.
Development and application of a double-piston configured, total-liquid ventilatory support device.
Meinhardt, J P; Quintel, M; Hirschl, R B
2000-05-01
Perfluorocarbon liquid ventilation has been shown to enhance pulmonary mechanics and gas exchange in the setting of respiratory failure. To optimize the total liquid ventilation process, we developed a volume-limited, time-cycled liquid ventilatory support, consisting of an electrically actuated, microprocessor-controlled, double-cylinder, piston pump with two separate limbs for active inspiration and expiration. Prospective, controlled, animal laboratory study, involving sequential application of conventional gas ventilation, partial ventilation (PLV), and total liquid ventilation (TLV). Research facility at a university medical center. A total of 12 normal adult New Zealand rabbits weighing 3.25+/-0.1 kg. Anesthestized rabbits were supported with gas ventilation for 30 mins (respiratory rate, 20 cycles/min; peak inspiratory pressure, 15 cm H2O; end-expiratory pressure, 5 cm H2O), then PLV was established with perflubron (12 mL/kg). After 15 mins, TLV was instituted (tidal volume, 18 mL/kg; respiratory rate, 7 cycles/min; inspiratory/expiratory ratio, 1:2 cycles/min). After 4 hrs of TLV, PLV was re-established. Of 12 animals, nine survived the 4-hr TLV period. During TLV, mean values +/- SEM were as follows: PaO2, 363+/-30 torr; PaCO2, 39+/-1.5 torr; pH, 7.39+/-0.01; static peak inspiratory pressure, 13.2+/-0.2 cm H2O; static endexpiratory pressure, 5.5+/-0.1 cm H2O. No significant changes were observed. When compared with gas ventilation and PLV, significant increases occurred in mean arterial pressure (62.4+/-3.5 torr vs. 74.0+/-1.2 torr) and central venous pressure (5.6+/-0.7 cm H2O vs. 7.8+/-0.2 cm H2O) (p < .05). Total liquid ventilation can be performed successfully utilizing piston pumps with active expiration. Considering the enhanced flow profiles, this device configuration provides advantages over others.
Effects of hydrostatic pressure on microbial alteration of sinking fecal pellets
NASA Astrophysics Data System (ADS)
Tamburini, Christian; Goutx, Madeleine; Guigue, Catherine; Garel, Marc; Lefèvre, Dominique; Charrière, Bruno; Sempéré, Richard; Pepa, Stéphane; Peterson, Michael L.; Wakeham, Stuart; Lee, Cindy
2009-08-01
We used a new experimental device called PASS (PArticle Sinking Simulator) during MedFlux to simulate changes in in situ hydrostatic pressure that particles experience sinking from mesopelagic to bathypelagic depths. Particles, largely fecal pellets, were collected at 200 m using a settling velocity NetTrap (SV NetTrap) in Ligurian Sea in April 2006 and incubated in high-pressure bottles (HPBs) of the PASS system under both atmospheric and continuously increasing pressure conditions, simulating the pressure change experienced at a sinking rate of 200 m d -1. Chemical changes over time were evaluated by measuring particulate organic carbon (POC), carbohydrates, transparent exopolymer particles (TEP), amino acids, lipids, and chloropigments, as well as dissolved organic carbon (DOC) and dissolved carbohydrates. Microbial changes were evaluated microscopically, using diamidinophenylindole (DAPI) stain for total cell counts and catalyzed reporter deposition-fluorescence in situ hybridization (CARD-FISH) for phylogenetic distinctions. Concentrations (normalized to POC) of particulate chloropigments, carbohydrates and TEP decreased under both sets of incubation conditions, although less under the increasing pressure regime than under atmospheric conditions. By contrast, dissolved carbohydrates (normalized to DOC) were higher after incubation and significantly higher under atmospheric conditions, suggesting they were produced at the expense of the particulate fraction. POC-normalized particulate wax/steryl esters increased only under pressure, suggesting biochemical responses of prokaryotes to the increasing pressure regime. The prokaryotic community initially consisted of 43% Bacteria, 12% Crenarchaea and 11% Euryarchaea. After incubation, Bacteria dominated (˜90%) the prokaryote community in all cases, with γ- Proteobacteria comprising the greatest fraction, followed by the Cytophaga-Flavobacter cluster and α -Proteobacteria group. Using the PASS system, we obtained chemical and microbial evidence that degradation by prokaryotes associated with fecal pellets sinking through mesopelagic waters is limited by the increasing pressure they experience.
Blood pressure and falls in community-dwelling people aged 60 years and older in the VHM&PP cohort.
Klein, Diana; Nagel, Gabriele; Kleiner, Andrea; Ulmer, Hanno; Rehberger, Barbara; Concin, Hans; Rapp, Kilian
2013-05-21
Falls are one of the major health problems in old people. Different risk factors were identified but only few epidemiological studies analysed the influence of conventionally measured blood pressure on falls. The objective of our study was to investigate the relationship between systolic and diastolic blood pressure and falls. In 3,544 community-dwelling Austrian women and men aged 60 years and older, data on falls within the previous three months were collected by questionnaire. Blood pressure was measured by general practitioners within the Vorarlberg Health Monitoring and Prevention Programme (VHM&PP) 90 to 1095 days before the fall assessment. A multiple logistic regression analysis was conducted. The models were stratified by gender and adjusted by age, number of medical conditions and subjective feeling of illness. In total, 257 falls in 3,544 persons were reported. In women, high systolic and diastolic blood pressure was associated with a decreased risk of falls. An increase of systolic blood pressure by 10 mmHg and of diastolic blood pressure by 5 mmHg reduced the risk of falling by 9% (OR 0.91, 95% Cl 0.84-0.98) and 8% (OR 0.92, 95% Cl 0.85-0.99), respectively. In men, an increased risk of falls was observed in participants with low systolic or low diastolic blood pressure. Blood pressure was associated with the risk of falls. Hypertensive values decreased the risk in women and low blood pressure increased the risk in men.
High-pressure dynamics of hydrated protein in bioprotective trehalose environment
Diallo, S. O.; Zhang, Q.; O'Neill, H.; ...
2014-10-30
Here we present a pressure-dependence study of the dynamics of lysozyme protein powder immersed in deuterated , α-trehalose environment via quasielastic neutron scattering (QENS). The goal is to assess the baroprotective benefits of trehalose on biomolecules by comparing the findings with those of a trehalose-free reference study. While the mean-square displacement of the trehalose-free protein (hydrated to d D₂O ≃40 w%) as a whole, is reduced by increasing pressure, the actual observable relaxation dynamics in the picoseconds to nanoseconds time range remains largely unaffected by pressure up to the maximum investigated pressure of 2.78(2) Kbar. Our observation is independent ofmore » whether or not the protein is mixed with the deuterated sugar. This suggests that the hydrated protein s conformational states at atmospheric pressure remain unaltered by hydrostatic pressures, below 2.78 Kbar. We also found the QENS response to be totally recoverable after ambient pressure conditions are restored. Small-angle neutron diffraction measurements confirm that the protein-protein correlation remains undisturbed.We observe, however, a clear narrowing of the QENS response as the temperature is decreased from 290 to 230 K in both cases, which we parametrize using the Kohlrausch-Williams-Watts stretched exponential model. Finally, only the fraction of protons that are immobile on the accessible time window of the instrument, referred to as the elastic incoherent structure factor, is observably sensitive to pressure, increasing only marginally but systematically with increasing pressure.« less
Dynamic void behavior in polymerizing polymethyl methacrylate cement.
Muller, Scott D; McCaskie, Andrew W
2006-02-01
Cement mantle voids remain controversial with respect to survival of total hip arthroplasty. Void evolution is poorly understood, and attempts at void manipulation can only be empirical. We induced voids in a cement model simulating the constraints of the proximal femur. Intravoid pressure and temperature were recorded throughout polymerization, and the initial and final void volumes were measured. Temperature-dependent peak intravoid pressures and void volume increases were observed. After solidification, subatmospheric intravoid pressures were observed. The magnitude of these observations could not be explained by the ideal gas law. Partial pressures of the void gas at peak pressures demonstrated a dominant effect of gaseous monomer, thereby suggesting that void growth is a pressure-driven phenomenon resulting from temperature-dependent evaporation of monomer into existing trapped air voids.
Plantar Pressures During Long Distance Running: An Investigation of 10 Marathon Runners
Hohmann, Erik; Reaburn, Peter; Tetsworth, Kevin; Imhoff, Andreas
2016-01-01
The objective of this study was to record plantar pressures using an in-shoe measuring system before, during, and after a marathon run in ten experienced long-distance runners with a mean age of 37.7 ± 11.5 years. Peak and mean plantar pressures were recorded before, after, and every three km during a marathon race. There were no significant changes over time in peak and mean plantar pressures for either the dominant or non-dominant foot. There were significant between foot peak and mean plantar pressure differences for the total foot (p = 0.0001), forefoot (p = 0.0001), midfoot (p = 0.02 resp. p = 0.006), hindfoot (p = 0.0001), first ray (p = 0.01 resp. p = 0.0001) and MTP (p = 0.05 resp. p = 0.0001). Long-distance runners do not demonstrate significant changes in mean or peak plantar foot pressures over the distance of a marathon race. However, athletes consistently favoured their dominant extremity, applying significantly higher plantar pressures through their dominant foot over the entire marathon distance. Key points Fatigue does not increase foot pressures Every runner has a dominant foot where pressures are higher and that he/she favours Foot pressures do not increase over the distance of a marathon run PMID:27274662
Drinking orange juice increases total antioxidant status and decreases lipid peroxidation in adults.
Foroudi, Shahrzad; Potter, Andrew S; Stamatikos, Alexis; Patil, Bhimanagouda S; Deyhim, Farzad
2014-05-01
Cardiovascular disease (CVD) is the leading cause of death in the world and is the primary cause of mortality among Americans. One of the many reasons for the pathogenesis of CVD is attributed to eating diets high in saturated fat and refined carbohydrates and low in fruits and vegetables. Epidemiological evidence has supported a strong association between eating diets rich in fruits and vegetables and cardiovascular health. An experiment was conducted utilizing 24 adults with hypercholesterolemia and hypertriglyceridemia to evaluate the impact of drinking 20 fl oz of freshly squeezed orange juice daily for 90 days on blood pressure, lipid panels, plasma antioxidant capacity, metabolic hormones, lipid peroxidation, and inflammatory markers. Except for addition of drinking orange juice, subjects did not modify their eating habits. The findings suggested that drinking orange juice does not affect (P>.1) blood pressure, lipid panels, metabolic hormones, body fat percentage, or inflammatory markers. However, total plasma antioxidant capacity was significantly increased (P<.05) and lipid peroxidation was significantly decreased (P<.05) after orange juice consumption. Drinking orange juice may protect the cardiovascular system by increasing total plasma antioxidant status and by lowering lipid peroxidation independent of other cardiovascular risk markers evaluated in this study.
NASA Technical Reports Server (NTRS)
Dupree, David T.; Hawkins, W. Kent
1947-01-01
A study has been made of the performance of the induction and the exhaust systems on the XR60 power-plant installation as part of an investigation conducted in the Cleveland altitude wind tunnel. Altitude flight conditions from 5000 to 30,000 feet were simulated for a range of engine powers from 750 to 3000 brake horsepower. Slipstream rotation prevented normal pressure recoveries in the right side of the main duct in the region of the right intercooler cooling-air duct inlet. Total-pressure losses in the charge-air flow between the turbosupercharger and the intercoolers were as high as 2.1 inches of mercury. The total-pressure distribution of the charge air at the intercooler inlets was irregular and varied as much as 1.0 inch of mercury from the average value at extreme conditions, Total-pressure surveys at the carburetor top deck showed a variation from the average value of 0.3 inch of mercury at take-off power and 0.05 inch of mercury at maximum cruising power, The carburetor preheater system increased the temperature of the engine charge air a maximum of about 82 F at an average cowl-inlet air temperature of 9 F, a pressure altitude of 5000 feet, and a brake horsepower of 1240.
Unsteady pressure loads in a generic high speed engine model
NASA Technical Reports Server (NTRS)
Parrott, Tony L.; Jones, Michael G.; Thurlow, Ernie M.
1992-01-01
Unsteady pressure loads were measured along the top interior wall of a generic high-speed engine (GHSE) model undergoing performance tests in the combustion-Heated Scramjet Test Facility at the Langley Research Center. Flow to the model inlet was simulated at 72000 ft and a flight Mach number of 4. The inlet Mach number was 3.5 with a total temperature and pressure of 1640 R and 92 psia. The unsteady pressure loads were measured with 5 piezoresistive gages, recessed into the wall 4 to 12 gage diameters to reduce incident heat flux to the diaphragms, and distributed from the inlet to the combustor. Contributors to the unsteady pressure loads included boundary layer turbulence, combustion noise, and transients generated by unstart loads. Typical turbulent boundary layer rms pressures in the inlet ranged from 133 dB in the inlet to 181 dB in the combustor over the frequency range from 0 to 5 kHz. Downstream of the inlet exist, combustion noise was shown to dominate boundary layer turbulence noise at increased heat release rates. Noise levels in the isolator section increased by 15 dB when the fuel-air ratio was increased from 0.37 to 0.57 of the stoichiometric ratio. Transient pressure disturbances associated with engine unstarts were measured in the inlet and have an upstream propagation speed of about 7 ft/sec and pressure jumps of at least 3 psia.
Blood Pressure Changes in Relation to Arsenic Exposure in a U.S. Pregnancy Cohort
Farzan, Shohreh F.; Chen, Yu; Wu, Fen; Jiang, Jieying; Liu, Mengling; Baker, Emily; Korrick, Susan A.
2015-01-01
Background Inorganic arsenic exposure has been related to the risk of increased blood pressure based largely on cross-sectional studies conducted in highly exposed populations. Pregnancy is a period of particular vulnerability to environmental insults. However, little is known about the cardiovascular impacts of arsenic exposure during pregnancy. Objectives We evaluated the association between prenatal arsenic exposure and maternal blood pressure over the course of pregnancy in a U.S. population. Methods The New Hampshire Birth Cohort Study is an ongoing prospective cohort study in which > 10% of participant household wells exceed the arsenic maximum contaminant level of 10 μg/L established by the U.S. EPA. Total urinary arsenic measured at 24–28 weeks gestation was measured and used as a biomarker of exposure during pregnancy in 514 pregnant women, 18–45 years of age, who used a private well in their household. Outcomes were repeated blood pressure measurements (systolic, diastolic, and pulse pressure) recorded during pregnancy. Results Using linear mixed effects models, we estimated that, on average, each 5-μg/L increase in urinary arsenic was associated with a 0.15-mmHg (95% CI: 0.02, 0.29; p = 0.022) increase in systolic blood pressure per month and a 0.14-mmHg (95% CI: 0.02, 0.25; p = 0.021) increase in pulse pressure per month over the course of pregnancy. Conclusions In our U.S. cohort of pregnant women, arsenic exposure was associated with greater increases in blood pressure over the course of pregnancy. These findings may have important implications because even modest increases in blood pressure impact cardiovascular disease risk. Citation Farzan SF, Chen Y, Wu F, Jiang J, Liu M, Baker E, Korrick SA, Karagas MR. 2015. Blood pressure changes in relation to arsenic exposure in a U.S. pregnancy cohort. Environ Health Perspect 123:999–1006; http://dx.doi.org/10.1289/ehp.1408472 PMID:25793356
Keefe, Douglas H.; Schairer, Kim S.
2011-01-01
An insert ear-canal probe including sound source and microphone can deliver a calibrated sound power level to the ear. The aural power absorbed is proportional to the product of mean-squared forward pressure, ear-canal area, and absorbance, in which the sound field is represented using forward (reverse) waves traveling toward (away from) the eardrum. Forward pressure is composed of incident pressure and its multiple internal reflections between eardrum and probe. Based on a database of measurements in normal-hearing adults from 0.22 to 8 kHz, the transfer-function level of forward relative to incident pressure is boosted below 0.7 kHz and within 4 dB above. The level of forward relative to total pressure is maximal close to 4 kHz with wide variability across ears. A spectrally flat incident-pressure level across frequency produces a nearly flat absorbed power level, in contrast to 19 dB changes in pressure level. Calibrating an ear-canal sound source based on absorbed power may be useful in audiological and research applications. Specifying the tip-to-tail level difference of the suppression tuning curve of stimulus frequency otoacoustic emissions in terms of absorbed power reveals increased cochlear gain at 8 kHz relative to the level difference measured using total pressure. PMID:21361437
Ground reaction forces and plantar pressure distribution during occasional loaded gait.
Castro, Marcelo; Abreu, Sofia; Sousa, Helena; Machado, Leandro; Santos, Rubim; Vilas-Boas, João Paulo
2013-05-01
This study compared the ground reaction forces (GRF) and plantar pressures between unloaded and occasional loaded gait. The GRF and plantar pressures of 60 participants were recorded during unloaded gait and occasional loaded gait (wearing a backpack that raised their body mass index to 30); this load criterion was adopted because is considered potentially harmful in permanent loaded gait (obese people). The results indicate an overall increase (absolute values) of GRF and plantar pressures during occasional loaded gait (p < 0.05); also, higher normalized (by total weight) values in the medial midfoot and toes, and lower values in the lateral rearfoot region were observed. During loaded gait the magnitude of the vertical GRF (impact and thrust maximum) decreased and the shear forces increased more than did the proportion of the load (normalized values). These data suggest a different pattern of GRF and plantar pressure distribution during occasional loaded compared to unloaded gait. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Woo, Seung Hoon; Kim, Jin Pyeong; Park, Jung Je; Shim, Hyun Seok; Lee, Sang Ha; Lee, Ho Joong; Won, Seong Jun; Son, Hee Young; Kim, Rock Bum
2013-01-01
Purpose The aim of this study was to compare a negative pressure drain with a natural drain in order to determine whether a negative pressure drainage tube causes an increase in the drainage volume. Materials and Methods Sixty-two patients who underwent total thyroidectomy for papillary thyroid carcinoma (PTC) were enrolled in the study between March 2010 and August 2010 at Gyeongsang National University Hospital. The patients were prospectively and randomly assigned to two groups, a negative pressure drainage group (n=32) and natural drainage group (n=30). Every 3 hours, the volume of drainage was checked in the two groups until the tube was removed. Results The amount of drainage during the first 24 hours postoperatively was 41.68±3.93 mL in the negative drain group and 25.3±2.68 mL in the natural drain group (p<0.001). After 24 additional hours, the negative drain group was 35.19±4.26 mL and natural drain groups 21.53±2.90 mL (p<0.001). However, the drainage at postoperative day 3 was not statistically different between the two groups. In addition, the vocal cord palsy and temporary and permanent hypocalcemia were not different between the two groups. Conclusion These results indicate that a negative pressure drain may increase the amount of drainage during the first 24-48 hours postoperatively. Therefore, it is not necessary to place a closed suction drain when only a total thyroidectomy is done. PMID:23225820
Güzel, Demet; Sayar, Sedat
2012-02-01
The effects of atmospheric pressure cooking (APC) and high-pressure cooking (HPC) on the physicochemical and nutritional properties of barlotto bean, chickpea, faba bean, and white kidney bean were investigated. The hardness of the legumes cooked by APC or HPC were not statistically different (P > 0.05). APC resulted in higher percentage of seed coat splits than HPC. Both cooking methods decreased Hunter "L" value significantly (P < 0.05). The "a" and "b" values of dark-colored seeds decreased after cooking, while these values tended to increase for the light-colored seeds. The total amounts of solid lost from legume seeds were higher after HPC compared with APC. Rapidly digestible starch (RDS) percentages increased considerably after both cooking methods. High pressure cooked legumes resulted in higher levels of resistant starch (RS) but lower levels of slowly digestible starch (SDS) than the atmospheric pressure cooked legumes.
Interaction of central venous pressure, intramuscular pressure, and carotid baroreflex function
NASA Technical Reports Server (NTRS)
Shi, X.; Foresman, B. H.; Raven, P. B.; Blomqvist, C. G. (Principal Investigator)
1997-01-01
Seven healthy volunteer men participated in an experiment involving lower body positive pressure (LBPP) of 30 Torr and acute volume expansions of 5-6% (VE-I) and 9-10% (VE-II) of their total blood volume (TBV) to differentiate the effect of increased intramuscular pressure and central venous pressure (CVP) on the maximal gain (Gmax) of the carotid baroreflex. During each experimental condition, the heart rate (HR), mean arterial pressure (MAP; intraradial artery or Finapres), and CVP (at the 3rd-4th intercostal space) were monitored continuously. Gmax was derived from the logistic modeling of the HR and MAP responses to ramped changes in carotid sinus transmural pressure using a protocol of pulsatile changes in neck chamber pressure from +40 to -65 Torr. The increase in CVP during +30-Torr LBPP was 1.5 mmHg (P < 0.05) and was similar to that observed during VE-I (1.7 mmHg, P > 0.05). The Gmax of the carotid baroreflex of HR and MAP was significantly decreased during LBPP by -0.145 +/- 0.039 beats x min(-1) x mmHg(-1) (38%) and -0.071 +/- 0.013 mmHg/mmHg (25%), respectively; however, VE-I did not affect Gmax. During VE-II, CVP was significantly greater than that elicited by LBPP, and the Gmax of the carotid baroreflex of the HR and MAP responses was significantly reduced. We conclude that carotid baroreflex responsiveness was selectively inhibited by increasing intramuscular pressure, possibly resulting in an activation of the intramuscular mechanoreceptors during LBPP. Furthermore, it would appear that the inhibition of the carotid baroreflex, via cardiopulmonary baroreceptor loading (increased CVP), occurred when a threshold pressure (CVP) was achieved.
Liu, Hao-Li; Hsieh, Han-Yi; Lu, Li-An; Kang, Chiao-Wen; Wu, Ming-Fang; Lin, Chun-Yen
2012-11-11
High-intensity focused-ultrasound (HIFU) has been successfully employed for thermal ablation of tumors in clinical settings. Continuous- or pulsed-mode HIFU may also induce a host antitumor immune response, mainly through expansion of antigen-presenting cells in response to increased cellular debris and through increased macrophage activation/infiltration. Here we demonstrated that another form of focused ultrasound delivery, using low-pressure, pulsed-mode exposure in the presence of microbubbles (MBs), may also trigger an antitumor immunological response and inhibit tumor growth. A total of 280 tumor-bearing animals were subjected to sonographically-guided FUS. Implanted tumors were exposed to low-pressure FUS (0.6 to 1.4 MPa) with MBs to increase the permeability of tumor microvasculature. Tumor progression was suppressed by both 0.6 and 1.4-MPa MB-enhanced FUS exposures. We observed a transient increase in infiltration of non-T regulatory (non-Treg) tumor infiltrating lymphocytes (TILs) and continual infiltration of CD8+ cytotoxic T-lymphocytes (CTL). The ratio of CD8+/Treg increased significantly and tumor growth was inhibited. Our findings suggest that low-pressure FUS exposure with MBs may constitute a useful tool for triggering an anticancer immune response, for potential cancer immunotherapy.
NASA Astrophysics Data System (ADS)
Saloum, S.; Naddaf, M.; Alkhaled, B.
2008-02-01
N2-x% Ar plasma gas mixture, generated in a hollow cathode RF discharge system, has been characterized by both optical emission spectroscopy (OES) and double Langmuir probe, as a function of experimental parameters: total pressure (5-33 Pa), and different fractions of argon (7 <= x <= 80), at a constant applied RF power of 300 W. N2 dissociation degree has been investigated qualitatively by both the actinometry method and the ratio I_N/I_{N_2} of the atomic nitrogen line emission intensity at 672.3 nm to the vibrational band (0-0) of the N2 second positive system at 337.1 nm. Both methods showed that the increase in argon fraction enhances the dissociation of N2, with a maximum at x = 50 for the pressure of 5 Pa, although the two methods give two opposite trends as a function of total pressure. Spectroscopic measurements showed that the vibrational temperature of the N2 second positive system increases with both argon fraction and total pressure increase, it lies between 4900 and 12 300 K. Langmuir probe measurements showed that, in the remote zone, the electron temperature falls in the range 1.57-1.75 eV, the N_{2}^{+} density varies between 5 × 109 and 1.4 × 1010 cm-3 and that both the plasma ionization degree and electron temperature increase towards the source. In addition, the process of plasma-polyamide (PA) surface interaction, in the remote plasma zone, has been studied through OES analysis during plasma treatment of PA to monitor the possible emissions due to the polymer etching. An increase in atomic nitrogen line (672.3 nm) intensity is obtained, atomic carbon line (833.52 nm) and the band emission (0-0) from the CN (B 2Σ+-X 2Σ+) violet system were observed. The PA surface modification has been confirmed through the improvement of its hydrophilic character as the water contact angle measured after the plasma treatment significantly decreased.
Kannan, Vinayagam; Balabathula, Pavan; Divi, Murali K; Thoma, Laura A; Wood, George C
2015-01-01
The effect of formulation and process parameters on drug loading and physical stability of paclitaxel-loaded long-circulating liposomes was evaluated. The liposomes were prepared by hydration-extrusion method. The formulation parameters such as total lipid content, cholesterol content, saturated-unsaturated lipid ratio, drug-lipid ratio and process parameters such as extrusion pressure and number of extrusion cycles were studied and their impact on drug loading and physical stability was evaluated. A proportionate increase in drug loading was observed with increase in the total phospholipid content. Cholesterol content and saturated lipid content in the bilayer showed a negative influence on drug loading. The short-term stability evaluation of liposomes prepared with different drug-lipid ratios demonstrated that 1:60 as the optimum drug-lipid ratio to achieve a loading of 1-1.3 mg/mL without the risk of physical instability. The vesicle size decreased with an increase in the extrusion pressure and number of extrusion cycles, but no significant trends were observed for drug loading with changes in process pressure or number of cycles. The optimization of formulation and process parameters led to a physically stable formulation of paclitaxel-loaded long-circulating liposomes that maintain size, charge and integrity during storage.
High-pressure dynamics of hydrated protein in bioprotective trehalose environment
NASA Astrophysics Data System (ADS)
Diallo, S. O.; Zhang, Q.; O'Neill, H.; Mamontov, E.
2014-10-01
We present a pressure-dependence study of the dynamics of lysozyme protein powder immersed in deuterated α ,α -trehalose environment via quasielastic neutron scattering (QENS). The goal is to assess the baroprotective benefits of trehalose on biomolecules by comparing the findings with those of a trehalose-free reference study. While the mean-square displacement of the trehalose-free protein (hydrated to dD2O≃ 40 w%) as a whole, is reduced by increasing pressure, the actual observable relaxation dynamics in the picoseconds to nanoseconds time range remains largely unaffected by pressure—up to the maximum investigated pressure of 2.78(2) Kbar. Our observation is independent of whether or not the protein is mixed with the deuterated sugar. This suggests that the hydrated protein's conformational states at atmospheric pressure remain unaltered by hydrostatic pressures, below 2.78 Kbar. We also found the QENS response to be totally recoverable after ambient pressure conditions are restored. Small-angle neutron diffraction measurements confirm that the protein-protein correlation remains undisturbed. We observe, however, a clear narrowing of the QENS response as the temperature is decreased from 290 to 230 K in both cases, which we parametrize using the Kohlrausch-Williams-Watts stretched exponential model. Only the fraction of protons that are immobile on the accessible time window of the instrument, referred to as the elastic incoherent structure factor, is observably sensitive to pressure, increasing only marginally but systematically with increasing pressure.
Study of Chromium Oxide Activities in EAF Slags
NASA Astrophysics Data System (ADS)
Yan, Baijun; Li, Fan; Wang, Hui; Sichen, Du
2016-02-01
The activity coefficients of chromium in Cu-Cr melts were determined by equilibrating liquid copper with solid Cr2O3 in CO-CO2 atmosphere. The temperature dependence of the activity coefficients of chromium in Cu-Cr melts could be expressed as lg γ_{Cr}(s)^{0} = { 3 2 5 9( ± 1 8 6} )/T - 0. 5 9( { ± 0. 1} ). Based on the above results, the activities of bivalent and trivalent chromium oxide in some slags at 1873 K (1600 °C) were measured. The slags were equilibrated with Cu-Cr melts under two oxygen partial pressures ( {p_{O}_{ 2} }} } = 6.9 × 10-4 and 1.8 × 10-6 Pa, respectively). The morphology of the quenched slags and the solubility of chromium oxide in the melts were investigated by EPMA, SEM, and XRD. Under both oxygen partial pressures, the slags were saturated by the solid solution MgAl2- x Cr x O4- δ . At the low oxygen partial pressure (1.8 × 10-6 Pa), the content of Cr in the liquid phase varied from 0.4 to 1.6 mass pct with the total Cr content in the slags increasing from 1.3 to 10.8 mass pct. At the high oxygen partial pressure (6.9 × 10-4 Pa), the content of Cr in the liquid phase decreased to the level of 0.2 to 0.6 mass pct. Both the activities of CrO and Cr2O3 in slag were found to increase approximately linearly with the increase of the total Cr content in slag. While the oxygen partial pressure had minor effect on the activity of Cr2O3 in the slag, it had significant effect on the activity of CrO.
[Trends in cardiovascular risk factors among urban Japanese male employees from 1977 to 2008].
Kitamura, Akihiko; Kiyama, Masahiko; Okada, Takeo; Maeda, Kenji; Ido, Masatoshi; Nakamura, Masakazu; Shimamoto, Takashi; Iida, Minoru; Ishikawa, Yoshinori
2010-01-01
In Japan, there is growing concern that employees' health condition has been worsening under the severe labor conditions of the continuing recent deep recession. To determine trends in the prevalence of cardiovascular risk factors among employees, we analyzed 32 yr of systematic surveillance of urban Japanese employed men. The surveyed population included male employees aged 40 to 59 yr who worked for four companies, a trading company, two banks and a company maintaining expressways in Osaka. Surveillance of cardiovascular risk factors was conducted from 1977 to 2008. We examined the annual mean values of systolic blood pressure, diastolic blood pressure, body mass index, and total serum cholesterol, and the prevalence of hypertension, obesity, hypercholesterolemia, smoking, alcohol drinkers, and high risk individuals who had two or more risk factors: (high blood pressure, high glucose and dyslipidemia). The total number of employees aged 40-59 yr increased from 822 in 1977 to 2,651 in 1992, but then declined gradually to 1,455 in 2008. Among men aged 40-49 and 50-59, the prevalence of hypertension decreased from 25% and 39% in 1977 to 14% and 23% in 1992, respectively. However, the respective prevalence of hypertension started to rise thereafter to 29% and 47% in 2008, accompanied by an increase in blood pressure levels and the prevalence of antihypertensive medication use. Mean body mass index and the prevalence of obesity showed significant upward linear trends from the mid-1980's to 2008. Therefore, we speculate that the increase in blood pressure levels seen after the early 1990's associated with an increase in obesity. However the proportion of hypertension among non-overweight men also increased between the early 1990's and 2008, suggesting other factors are also involved in the increase of hypertension. The prevalence of hypercholesterolemia and high-risk individuals with obesity also increased in recent years. Mean total cholesterol level showed a linear increase from 195 mg/dl for men aged 40-49 and 196 mg/dl for men aged 50-59 in 1977 to 204 mg/dl and 207 mg/dl in 2008, respectively. The prevalence of high-risk individuals with obesity was 13% for men aged 40-49 and 15% for men aged 50-59 in 2008. Among men aged 50-59, the prevalence of non-overweight high-risk individuals became higher than that of high-risk individuals with obesity over time. Although these findings were limited to the study companies, our data support evidence that Japanese employees have become increasingly at risk of cardiovascular diseases under the severe working conditions experienced since the 1990's. It is important to improve working conditions as well as personally control risk factors from the point of public health.
Quantifying mortal injury of juvenile Chinook salmon exposed to simulated hydro-turbine passage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Richard S.; Carlson, Thomas J.; Gingerich, Andrew J.
A proportion of juvenile Chinook salmon and other salmonids travel through one or more turbines during seaward migration in the Columbia and Snake River every year. Despite this understanding, limited information exists on how these fish respond to hydraulic pressures found during turbine passage events. In this study we exposed juvenile Chinook salmon to varied acclimation pressures and subsequent exposure pressures (nadir) to mimic the hydraulic pressures of large Kaplan turbines (ratio of pressure change). Additionally, we varied abiotic (total dissolved gas, rate of pressure change) and biotic (condition factor, fish length, fish weight) factors that may contribute to themore » incidence of mortal injury associated with fish passing through hydro-turbines. We determined that the main factor associated with mortal injury of juvenile Chinook salmon during simulated turbine passage was the ratio between acclimation and nadir pressures. Condition factor, total dissolved gas, and the rate of pressure change were found to only slightly increase the predictive power of equations relating probability of mortal injury to conditions of exposure or characteristics of test fish during simulated turbine passage. This research will assist engineers and fisheries managers in operating and improving hydroelectric facility efficiency while minimizing mortality and injury of turbine-passed juvenile Chinook salmon. The results are discussed in the context of turbine development and the necessity of understanding how different species of fish will respond to the hydraulic pressures of turbine passage.« less
Chiu, Christine L; Lujic, Sanja; Thornton, Charlene; O'Loughlin, Aiden; Makris, Angela; Hennessy, Annemarie; Lind, Joanne M
2012-01-01
The relationship between menopausal hormone therapy (MHT) and cardiovascular risk remains controversial, with a number of studies advocating the use of MHT in reducing risk of cardiovascular diseases, while others have shown it to increase risk. The aim of this study was to determine the association between menopausal hormone therapy and high blood pressure. A total of 43,405 postmenopausal women were included in the study. Baseline data for these women were sourced from the 45 and Up Study, Australia, a large scale study of healthy ageing. These women reported being postmenopausal, having an intact uterus, and had not been diagnosed with high blood pressure prior to menopause. Odds ratios for the association between MHT use and having high blood pressure were estimated using logistic regression, stratified by age (<56 years, 56-61 years, 62-70 years and over 71 years) and adjusted for demographic and lifestyle factors. MHT use was associated with higher odds of having high blood pressure: past menopausal hormone therapy use: <56 years (adjusted odds ratio 1.59, 99% confidence interval 1.15 to 2.20); 56-61 years (1.58, 1.31 to 1.90); 62-70 years (1.26, 1.10 to 1.44). Increased duration of hormone use was associated with higher odds of having high blood pressure, with the effect of hormone therapy use diminishing with increasing age. Menopausal hormone therapy use is associated with significantly higher odds of having high blood pressure, and the odds increase with increased duration of use. High blood pressure should be conveyed as a health risk for people considering MHT use.
NASA Astrophysics Data System (ADS)
Nakamura, Y.; Aoki, A.
Effects of sub-atmospheric ambient pressure and oxygen content on irradiated ignition characteristics of solid combustibles were examined experimentally in order to elucidate the flammability and chance of fire in depressurized systems and give ideas for the fire safety and fire fighting strategies for such environments. Thin cellulosic paper was used as the solid combustible since cellulose is one of major organic compounds and flammables in the nature. Applied atmospheres consisted of inert gases (either CO 2 or N 2) and oxygen at various mixture ratios. Total ambient pressure ( P) was varied from 101 kPa (standard atmospheric pressure, P0) to 20 kPa. Ignition was initiated by external thermal radiation with CO 2 laser (10 W total; 21.3 W/cm 2 of the corresponding peak flux) onto the solid surface. Thermal degradation of the solid produced combustible gaseous products (e.g. CO, H 2, or other low weight of HCs) and these products mixed with ambient oxygen to form the combustible mixture over the solid. Heat transfer from the irradiated surface into the mixture accelerated the exothermic reaction in the gas phase and finally thermal runaway (ignition) was achieved. A digital video camera was used to analyze the ignition characteristics. Flammability maps in partial pressure of oxygen (ppO 2) and normalized ambient pressure ( P/ P0) plane were made to reveal the fire hazard in depressurized environments. Results showed that a wider flammable range was obtained in sub-atmospherics conditions. In middle pressure range (101-40 kPa), the required ppO 2 for ignition decreased almost linearly as the total pressure decreased, indicating that higher fire risk is expected. In lower pressure range (<40 kPa), the required partial pressure of oxygen increased dramatically, then ignition was eventually not achieved at pressures less than 20 kPa under the conditions studied here. The findings suggest that it might be difficult to satisfy safety in space agriculture since it has been reported that higher oxygen concentrations are preferable for plant growth in depressurized environments. Our results imply that there is an optimum pressure level to achieve less fire chance with acceptable plant growth. An increase of the flammable range in middle pressure level might be explained by following two effects: one is a physical effect, such as a weak convective thermal removal from ignitable domain (near the hot surface) to the ambient of atmosphere, and the other is chemical effect which causes so-called "explosion peninsula" as a result of depleting radical consumption due to third-body recombination reaction. Further studies are necessary to determine the controlling factor on the observed flammable trend in depressurized conditions.
Walsh, Tom P; Butterworth, Paul A; Urquhart, Donna M; Cicuttini, Flavia M; Landorf, Karl B; Wluka, Anita E; Michael Shanahan, E; Menz, Hylton B
2017-01-01
There is a well-recognised relationship between body weight, plantar pressures and foot pain, but the temporal association between these factors is unknown. The aim of this study was to investigate the relationships between increasing weight, plantar pressures and foot pain over a two-year period. Fifty-one participants (33 women and 18 men) completed the two-year longitudinal cohort study. The sample had a mean (standard deviation (SD)) age of 52.6 (8.5) years. At baseline and follow-up, participants completed the Manchester Foot Pain and Disability Index questionnaire, and underwent anthropometric measures, including body weight, body mass index, and dynamic plantar pressures. Within-group analyses examined differences in body weight, foot pain and plantar pressures between baseline and follow up, and multivariate regression analysis examined associations between change in body weight, foot pain and plantar pressure. Path analysis assessed the total impact of both the direct and indirect effects of change in body weight on plantar pressure and pain variables. Mean (SD) body weight increased from 80.3 (19.3), to 82.3 (20.6) kg, p = 0.016 from baseline to follow up. The change in body weight ranged from -16.1 to 12.7 kg. The heel was the only site to exhibit increased peak plantar pressures between baseline and follow up. After adjustment for age, gender and change in contact time (where appropriate), there were significant associations between: (i) change in body weight and changes in midfoot plantar pressure ( B = 4.648, p = 0.038) and functional limitation ( B = 0.409, p = 0.010), (ii) plantar pressure change in the heel and both functional limitation ( B = 4.054, p = 0.013) and pain intensity ( B = 1.831, p = 0.006), (iii) plantar pressure change in the midfoot and both functional limitation ( B = 4.505 , p = 0.018) and pain intensity ( B = 1.913 , p = 0.015) . Path analysis indicated that the effect of increasing body weight on foot-related functional limitation and foot pain intensity may be mediated by increased plantar pressure in the midfoot. These findings suggest that as body weight and plantar pressure increase, foot pain increases, and that the midfoot may be the most vulnerable site for pressure-related pain.
Hart, Emma C; Joyner, Michael J; Wallin, B Gunnar; Charkoudian, Nisha
2012-05-01
Young women tend to have lower blood pressure, and less risk of hypertension, compared to young men. As people age, both blood pressure and the risk of hypertension increase in both sexes; this occurs most strikingly in women after menopause. However, the mechanisms for these influences of sex and age remain incompletely understood. In this review we are specifically interested in the interaction between neural (sympathetic nerve activity; SNA) and haemodynamic factors (cardiac output, blood pressure and vascular resistance) and how these change with sex and age. While peripheral vascular SNA can vary 7- to 10-fold among normotensive young men and women, it is reproducible in a given individual. Surprisingly, higher levels of SNA are not associated with higher blood pressures in these groups. In young men, high SNA is associated with higher total peripheral vascular resistance (TPR), and appears to be balanced by lower cardiac output and less peripheral vascular responsiveness to adrenergic stimulation. Young women do not exhibit the SNA-TPR relationship. Recent evidence suggests that β-adrenergic vasodilatation offsets the vasoconstrictor effects of α-adrenergic vasoconstriction in young women, which may contribute to the generally lower blood pressures in this group. Sympathetic nerve activity increases with age, and in groups over 40, levels of SNA are more tightly linked to levels of blood pressure. The potentially protective β-adrenergic effect seen in young women appears to be lost after menopause and probably contributes to the increased blood pressure and increased risk of hypertension seen in older women.
Clinical characteristics and predictive factors of subclinical diabetic nephropathy.
Zhang, Y; Yang, J; Zheng, M; Wang, Y; Ren, H; Xu, Y; Yang, Y; Cheng, J; Han, F; Yang, X; Chen, L; Shan, C; Chang, B
2015-02-01
To investigate the clinical characteristics and predictive factors of subclinical diabetic nephropathy in type 2 diabetes patients. A total of 298 type 2 diabetes patients were divided into 3 groups based on 24-h urinary microalbumin and estimated glomerular filtration rate: patients with normal albuminuria and glomerular filtration rate (NC), patients with normoalbuminuria and glomerular hyperfiltration (SDN) and patients with microalbuminuria (EDN). The renal size, tubular injury markers and ambulatory blood pressure were analyzed. Renal size increased in the SDN and EDN groups compared to the NC group (P<0.05), while renal length in the SDN group was greater than the EDN group (P<0.05). Patients in the SDN and EDN groups had higher level of urine retinol binding protein and N-acetyl-β-D-glucosaminidase and most of them developed proximal tubular dysfunction. The SDN group had higher 24-h mean and nocturnal diastolic blood pressure than the NC group (P<0.05), while the EDN group had higher systolic blood pressure and pulse pressure than the SDN group (P<0.01). More patients developed abnormal blood pressure rhythm in the SDN and EDN groups. The likelihood of a decrease in nocturnal systolic blood pressure was lower as the microalbuminuria increased. Increased renal size, more abnormal tubular injury markers and higher 24-h mean and nocturnal blood pressure were all risk factors of subclinical diabetic nephropathy. Patients with subclinical diabetic nephropathy had increased renal size, abnormal tubular injury markers, high blood pressure and abnormal circadian rhythm. © Georg Thieme Verlag KG Stuttgart · New York.
Effect of Achilles tendon loading on plantar fascia tension in the standing foot.
Cheung, Jason Tak-Man; Zhang, Ming; An, Kai-Nan
2006-02-01
The plantar fascia, which is one of the major arch-supporting structures of the human foot, sustains high tensions during weight-bearing. A positive correlation between Achilles tendon loading and plantar fascia tension has been reported. Excessive stretching and tightness of the Achilles tendon are thought to be the risk factors of plantar fasciitis but their biomechanical effects on the plantar fascia have not been fully addressed. A three-dimensional finite element model of the human foot and ankle, incorporating geometrical and material nonlinearity, was employed to investigate the loading response of the plantar fascia in the standing foot with different magnitudes of Achilles tendon loading. With the total ground reaction forces of one foot maintained at 350 N to represent half body weight, an increase in Achilles tendon load from (0-700 N) resulted in a general increase in total force and peak plantar pressure at the forefoot of up to about 250%. There was a lateral and anterior shift of the centre of pressure and a reduction in the arch height with an increasing Achilles tendon load as a result of the plantar flexion moment on the calcaneus. From the finite element predictions of simulated balanced standing, Achilles tendon forces of 75% of the total weight on the foot (350 N) were found to provide the closest match of the measured centre of pressure of the subject during balanced standing. Both the weight on the foot and Achilles tendon loading resulted in an increase in tension of the plantar fascia with the latter showing a two-times larger straining effect. Increasing tension on the Achilles tendon is coupled with an increasing strain on the plantar fascia. Overstretching of the Achilles tendon resulting from intense muscle contraction and passive stretching of tight Achilles tendon are plausible mechanical factors for overstraining of the plantar fascia.
Zhu, Pengli; Huang, Feng; Lin, Fan; Yuan, Yin; Chen, Falin; Li, Qiaowei
2013-11-01
To describe the relationship of plasma apelin levels with blood pressure in a coastal Chinese population. This cross-sectional study included a total of 1031 subjects from the coastal areas of China. One-way analysis of variance (ANOVA) and linear trend test, Pearson's correlation analysis, as well as multivariate linear regression analysis were used to evaluate the association between plasma apelin levels and blood pressure. Plasma apelin levels dropped with increasing quartiles of systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean arterial blood pressure (MABP) (all P<0.001). SBP, DBP, and MABP values decreased as the apelin levels increased within the quartiles. After adjusting for age and gender, the significant differences in SBP, DBP, and MABP between the groups within the apelin quartiles remained (all P<0.05). A significant negative correlation between SBP, DBP, as well as MABP and apelin levels was observed (all P<0.01); even after adjusting for cardiovascular confounding factors, this negative correlation remained (all P<0.001). A negative correlation between plasma apelin levels and blood pressure was found in this 1000-population-based epidemiological study. Apelin may become a potential therapeutic target of anti-hypertensive treatment.
Excess air during aquifer storage and recovery in an arid basin (Las Vegas Valley, USA)
NASA Astrophysics Data System (ADS)
Solomon, D. Kip; Cole, Erin; Leising, Joseph F.
2011-02-01
The Las Vegas Valley Water District in Nevada, USA, has operated an artificial recharge (AR) program since 1989. In summer 2001, observations of gas exsolving from tap water prompted a study that revealed total dissolved gas (TDG) pressures approaching 2 atm with a gas composition that it is predominantly air. Measurements of TDG pressure at well heads and in the distribution system indicated two potential mechanisms for elevated TDG pressures: (1) air entrainment during AR operations, and (2) temperature changes between the winter recharge season and the summer withdrawal season. Air entrainment during pumping was investigated by intentionally allowing the forebay (upstream reservoir) of a large pumping station to drawdown to the point of vortex formation. This resulted in up to a 0.7 atm increase in TDG pressure. In general, the solubility of gases in water decreases as the temperature increases. In the Las Vegas Valley, water that acquired a modest amount of dissolved gas during winter artificial recharge operations experienced an increase in dissolved gas pressure (0.04 atm/°C) as the water warmed in the subsurface. A combination of air entrainment during AR operations and its amplification by temperature increase after recharge can account for most of the observed amounts of excess gas at this site.
Coakley, Raymond D.; Button, Brian; Henderson, Ashley G.; Zeman, Kirby L.; Alexis, Neil E.; Peden, David B.; Lazarowski, Eduardo R.; Davis, C. William; Bailey, Summer; Fuller, Fred; Almond, Martha; Qaqish, Bahjat; Bordonali, Elena; Rubinstein, Michael; Bennett, William D.; Kesimer, Mehmet; Boucher, Richard C.
2015-01-01
Rationale: Chronic bronchitis (CB) is characterized by persistent cough and sputum production. Studies were performed to test whether mucus hyperconcentration and increased partial osmotic pressure, in part caused by abnormal purine nucleotide regulation of ion transport, contribute to the pathogenesis of CB. Objectives: We tested the hypothesis that CB is characterized by mucus hyperconcentration, increased mucus partial osmotic pressures, and reduced mucus clearance. Methods: We measured in subjects with CB as compared with normal and asymptomatic smoking control subjects indices of mucus concentration (hydration; i.e., percentage solids) and sputum adenine nucleotide/nucleoside concentrations. In addition, sputum partial osmotic pressures and mucus transport rates were measured in subjects with CB. Measurements and Results: CB secretions were hyperconcentrated as indexed by an increase in percentage solids and total mucins, in part reflecting decreased extracellular nucleotide/nucleoside concentrations. CB mucus generated concentration-dependent increases in partial osmotic pressures into ranges predicted to reduce mucus transport. Mucociliary clearance (MCC) in subjects with CB was negatively correlated with mucus concentration (percentage solids). As a test of relationships between mucus concentration and disease, mucus concentrations and MCC were compared with FEV1, and both were significantly correlated. Conclusions: Abnormal regulation of airway surface hydration may slow MCC in CB and contribute to disease pathogenesis. PMID:25909230
Nakamura, Sachiko; Adachi, Hisashi; Enomoto, Mika; Fukami, Ako; Kumagai, Eita; Nohara, Yume; Kono, Shoko; Nakao, Erika; Sakaue, Akiko; Tsuru, Tomoko; Morikawa, Nagisa; Fukumoto, Yoshihiro
2017-10-01
An understanding of the trends in regard to coronary risk factors and electrocardiogram (ECG) findings has an important role in public health. We investigated the trends in coronary risk factors and main ECG findings in 1977, 1989, 1999, and 2009 in the Japanese cohort of the Seven Countries Study, in Tanushimaru, a typical farming town on Kyushu Island. A total of 1397 subjects (231 in 1977, 332 in 1989, 389 in 1999, and 445 in 2009) were enrolled in this study, and all of them were males aged over 65 years. In coronary risk factors, total cholesterol levels, diastolic blood pressure, body mass index, and uric acid significantly increased during these 3 decades. The prevalence of smokers markedly decreased from 56.7% in 1977 to 16.8% in 2009. ECG changes during 3 decades were wider QRS interval, increased prevalence of major abnormality, reduced heart rate, shortened PR interval and corrected QT, and decreased prevalence of left ventricular hypertrophy. Age, smoking habits, major and minor abnormalities in ECG were associated with mortality in 1977-1987. Age, total cholesterol levels (inversely) and corrected QT were associated with mortality in 1989-1999. Age, smoking habits, heart rate, and systolic blood pressure were associated with mortality in 1999-2009. Predictors of mortality have changed with the times. Coronary risk factors such as smoking, increased heart rate, and elevated blood pressure have been recently associated with mortalities in elderly male Japanese general population. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Rodriguez-Roca, Gustavo C; Llisterri-Caro, Jose L; Barrios-Alonso, Vivencio; Alonso-Moreno, Francisco J; Lou-Arnal, Salvador; Prieto-Diaz, Miguel A; Sanchez-Ruiz, Tomas; Dura-Belinchon, Rafael; Santos-Rodriguez, Jose A; Divison-Garrote, Juan A; Gonzalez-Segura, Diego; Banegas-Banegas, Jose R
2009-01-01
To analyse the cardiovascular risk of a broad sample of hypertensive patients and to examine whether there are differences in blood pressure control and associated factors according to the different cardiovascular risk categories. A total of 10,520 patients > or = 18 years old were included (mean age 64.6+/-11.3 years; 53.7% women). In this cohort, 3.3% were average risk, 22.6% low added risk, 22.2% moderate added risk, 33.5% high added risk and 18.4% very high added risk. Blood pressure was controlled in 41.4% (95% CI 40.5-42.4) of the total population, in 91.7% of patients with low added risk, in 19.4% with moderate added risk, in 27.4% with high added risk and in 6.8% with very high added risk. Diabetes was the factor most strongly associated with poor blood pressure control in patients with high to very high added risk (OR=7.2; p<0.0001). More than half of the hypertensive patients treated in primary health care have a high or very high added cardiovascular risk. In these patients, blood pressure control is inadequate and diabetes is associated with a sevenfold increase in the likelihood of poor blood pressure control.
NASA Technical Reports Server (NTRS)
Brown, C. A., Jr.; Campbell, J. F.
1971-01-01
The flow properties in the wake of a 140 deg-included-angle cone at Mach numbers from 1.60 to 3.95 and at angles of attack of 0 deg and 5 deg are discussed. The wake flow properties are calculated from total and static pressures measured with a pressure rake at longitudinal stations varying from 1.0 to 8.39 body diameters and at lateral stations varying from -0.42 to 3.0 body diameters. These measurements show a consistent trend throughout the range of Mach number and longitudinal distance and an increase in dynamic pressure with increasing longitudinal station.
NASA Technical Reports Server (NTRS)
Brown, C. A., Jr.; Campbell, J. F.; Tudor, D. H.
1971-01-01
An investigation was conducted to obtain flow properties in the wake of the Viking '75 entry vehicle at Mach numbers from 1.60 to 3.95 and at angles of attack of 0 deg and 5 deg. The wake flow properties were calculated from total and static pressures measured with a pressure rake at longitudinal stations varying from 1.0 to 8.39 body diameters and lateral stations varying from -0.42 to 3.0 body diameters. These measurements showed a a consistent trend throughout the range of Mach numbers and longitudinal distances and an increase in dynamic pressure with increasing downstream position.
Shim, J W; Elder, S H
2006-11-01
The goal of this study was to demonstrate whether cyclically imposed hydrostatic pressure, compressive in nature, could induce fibrocartilaginous metaplasia in a purely tendinous cell source in vitro. The effect of short-duration cyclic hydrostatic pressure on tendon fibroblasts (tenocytes) expanded from rat Achilles tendon was studied. Total RNA was isolated either immediately after loading or 24 h later. The mRNA expression of tendon and cartilage specific markers - Collagen types I and II, Sox9, and Aggrecan was quantified by real-time reverse transcription polymerase chain reaction over multiple biological samples (n=6). For immediately isolated RNA samples, there were statistically significant increases in mRNA expression of Aggrecan and Collagen type II, while Collagen type I significantly decreased. Noticeably, for RNA samples isolated 24 h later, there were further increases in mRNA expression of Aggrecan and Collagen type II, whereas Collagen type I increased roughly three-fold relative to the non-loaded control. These findings support the hypothesis that cyclic hydrostatic pressurization can induce fibrocartilaginous metaplasia in tenocytes by upregulation of cartilaginous gene expression. Also, it was demonstrated that changes in mRNA expression as a result of single 2 h pressurization persist even up to 24 h.
NASA Technical Reports Server (NTRS)
Dittrich, Ralph T
1957-01-01
An experimental investigation of combustor total-pressure loss was undertaken to confirm previous theoretical analyses of effects of geometric and flow variables and of heat addition. The results indicate that a reasonable estimate of cold-flow total-pressure-loss coefficient may be obtained from the theoretical analyses. Calculated total-pressure loss due to heat addition agreed with experimental data only when there was no flame ejection from the liner at the upstream air-entry holes.
NASA Astrophysics Data System (ADS)
Vollmer, B.; Wong, O. I.; Braine, J.; Chung, A.; Kenney, J. D. P.
2012-07-01
The influence of the environment on gas surface density and star formation efficiency of cluster spiral galaxies is investigated. We extend previous work on radial profiles by a pixel-to pixel analysis looking for asymmetries due to environmental interactions. The star formation rate is derived from GALEX UV and Spitzer total infrared data based on the 8, 24, 70, and 160 μm data. As in field galaxies, the star formation rate for most Virgo galaxies is approximately proportional to the molecular gas mass. Except for NGC 4438, the cluster environment does not affect the star formation efficiency with respect to the molecular gas. Gas truncation is not associated with major changes in the total gas surface density distribution of the inner disk of Virgo spiral galaxies. In three galaxies (NGC 4430, NGC 4501, and NGC 4522), possible increases in the molecular fraction and the star formation efficiency with respect to the total gas, of factors of 1.5 to 2, are observed on the windward side of the galactic disk. A significant increase of the star formation efficiency with respect to the molecular gas content on the windward side of ram pressure-stripped galaxies is not observed. The ram-pressure stripped extraplanar gas of 3 highly inclined spiral galaxies (NGC 4330, NGC 4438, and NGC 4522) shows a depressed star formation efficiency with respect to the total gas, and one of them (NGC 4438) shows a depressed rate even with respect to the molecular gas. The interpretation is that stripped gas loses the gravitational confinement and associated pressure of the galactic disk, and the gas flow is diverging, so the gas density decreases and the star formation rate drops. We found two such regions of low star formation efficiency in the more face-on galaxies NGC 4501 and NGC 4654 which are both undergoing ram pressure stripping. These regions show low radio continuum emission or unusually steep radio spectral index. However, the stripped extraplanar gas in one highly inclined galaxy (NGC 4569) shows a normal star formation efficiency with respect to the total gas. We propose this galaxy is different because it is observed long after peak pressure, and its extraplanar gas is now in a converging flow as it resettles back into the disk. Appendices are available in electronic form http://www.aanda.org
Textbook Forum. Thermodynamics of "Mixing" of Ideal Gases: A Persistent Pitfall.
ERIC Educational Resources Information Center
Meyer, Edwin F.
1987-01-01
Discusses some of the misconceptions commonly held suggesting that mixing ideal gases causes an increase in entropy. Argues that the combining processes and resulting total pressure have absolutely nothing to do with the mixing itself. (TW)
Effects of heart rate on experimentally produced mitral regurgitation in dogs.
Yoran, C; Yellin, E L; Hori, M; Tsujioka, K; Laniado, S; Sonnenblick, E H; Frater, R W
1983-12-01
The effects of increasing heart rate (HR) on the hemodynamics of acute mitral regurgitation (MR) were studied in 8 open-chest dogs. Filling volume, regurgitant volume and stroke volume were calculated from electromagnetic probe measurements of mitral and aortic flows. The left atrial-left ventricular systolic pressure gradient was measured with micromanometers. The calculated effective mitral regurgitant orifice area varied from 10 to 128 mm2, with a consequent regurgitant fraction (regurgitant volume/filling volume) of 24 to 62%. After crushing the sinus node, HR was increased stepwise from 90 to 180 beats/min by atrial pacing while maintaining aortic pressure constant. With increasing HR, filling volume, stroke volume, regurgitant volume and regurgitant time decreased; total cardiac output, forward cardiac output, regurgitant output, systolic pressure gradient, regurgitant fraction and the regurgitant orifice did not change; left ventricular end-diastolic pressure decreased; and left atrial v-wave amplitude increased. These results indicate that in acute experimental MR with a wide spectrum of incompetence, the relative distribution of forward and regurgitant flows did not change with large increases in HR. At rates greater than 150 beats/min the atrial contraction occurs early and increases the amplitude of the left atrial v wave. This may contribute to the severity of pulmonary congestion in patients with MR.
Large Scale Flame Spread Environmental Characterization Testing
NASA Technical Reports Server (NTRS)
Clayman, Lauren K.; Olson, Sandra L.; Gokoghi, Suleyman A.; Brooker, John E.; Ferkul, Paul V.; Kacher, Henry F.
2013-01-01
Under the Advanced Exploration Systems (AES) Spacecraft Fire Safety Demonstration Project (SFSDP), as a risk mitigation activity in support of the development of a large-scale fire demonstration experiment in microgravity, flame-spread tests were conducted in normal gravity on thin, cellulose-based fuels in a sealed chamber. The primary objective of the tests was to measure pressure rise in a chamber as sample material, burning direction (upward/downward), total heat release, heat release rate, and heat loss mechanisms were varied between tests. A Design of Experiments (DOE) method was imposed to produce an array of tests from a fixed set of constraints and a coupled response model was developed. Supplementary tests were run without experimental design to additionally vary select parameters such as initial chamber pressure. The starting chamber pressure for each test was set below atmospheric to prevent chamber overpressure. Bottom ignition, or upward propagating burns, produced rapid acceleratory turbulent flame spread. Pressure rise in the chamber increases as the amount of fuel burned increases mainly because of the larger amount of heat generation and, to a much smaller extent, due to the increase in gaseous number of moles. Top ignition, or downward propagating burns, produced a steady flame spread with a very small flat flame across the burning edge. Steady-state pressure is achieved during downward flame spread as the pressure rises and plateaus. This indicates that the heat generation by the flame matches the heat loss to surroundings during the longer, slower downward burns. One heat loss mechanism included mounting a heat exchanger directly above the burning sample in the path of the plume to act as a heat sink and more efficiently dissipate the heat due to the combustion event. This proved an effective means for chamber overpressure mitigation for those tests producing the most total heat release and thusly was determined to be a feasible mitigation strategy to incorporate into the microgravity experiment.
Cardiovascular and Body Fluid Adjustments During Bed Rest and Space Flight
NASA Technical Reports Server (NTRS)
Greenleaf, John E.; Tomko, David L. (Technical Monitor)
1995-01-01
Although a few scientific bed rest (BR) studies were conducted soon after World War II, advent of the space program provided impetus for utilizing prolonged (days-months) BR, which employed the horizontal or 6 degree head-down tilt (HDT) body positions, to simulate responses of healthy people to microgravity. Shorter (hours) HDT protocols were used to study initial mechanisms of the acclimation-deconditioning (reduction of physical fitness) syndromes. Of the major physiological factors modified during BR, reduced force on bones, ligaments, and muscles, and greatly reduced hydrostatic pressure within the cardiovascular system, the latter: which involves shifts of blood from the lower extremities into the upper body, increase in central venous pressure, and diuresis, appears to be the initial stimulus for acclimation. Increase in central venous pressure occurs in subjects during weightless parabolic flight, but not in astronauts early during orbital flight. But significant reduction in total body water (hypohydration) and plasma volume (hypovolemia) occurs in subjects during both BR and microgravity. Response of interstitial fluid volume is not as clear, It has been reported to increase during BR, and it may have increased in Skylab II and IV astronauts. Reduction of total body water, and greater proportional reduction of extracellular volume, indicates increased cellular volume which may contribute to inflight cephalic edema. Cerebral pressure abates after a few days of HDT, but not during flight. accompanied by normal (eugravity) blood constituent concentrations suggesting some degree of acclimation had occurred. But during reentry, with moderately increased +Gz (head-to-foot) acceleration and gravitational force, the microgravity "euhydration" becomes functional progressive dehydration contributing to the general reentry syndrome (GRS) which, upon landing the Shuttle, can and often results in gastrointestinal distress, disorientation, vertigo, fatigue, and fainting. Various pre-reentry hyperhydration procedures have been utilized to counteract the GRS. Thus, the somewhat decreased central venous pressure and lack of diuresis early in spaceflight suggests mechanisms other than the Gauer-Henry reflex are more important for maintaining fluid volume homeostasis in astronauts. Inflight hypohydration and hypovolemia are more important for maintaining fluid volume homeostasis in astronauts.
Baicu, Catalin F; Li, Jiayu; Zhang, Yuhua; Kasiganesan, Harinath; Cooper, George; Zile, Michael R; Bradshaw, Amy D
2012-11-01
Myocardial fibrillar collagen is considered an important determinant of increased ventricular stiffness in pressure-overload (PO)-induced cardiac hypertrophy. Chronic PO was created in feline right ventricles (RV) by pulmonary artery banding (PAB) to define the time course of changes in fibrillar collagen content after PO using a nonrodent model and to determine whether this time course was dependent on changes in fibroblast function. Total, soluble, and insoluble collagen (hydroxyproline), collagen volume fraction (CVF), and RV end-diastolic pressure were assessed 2 days and 1, 2, 4, and 10 wk following PAB. Fibroblast function was assessed by quantitating the product of postsynthetic processing, insoluble collagen, and levels of SPARC (secreted protein acidic and rich in cysteine), a protein that affects procollagen processing. RV hypertrophic growth was complete 2 wk after PAB. Changes in RV collagen content did not follow the same time course. Two weeks after PAB, there were elevations in total collagen (control RV: 8.84 ± 1.03 mg/g vs. 2-wk PAB: 11.50 ± 0.78 mg/g); however, increased insoluble fibrillar collagen, as measured by CVF, was not detected until 4 wk after PAB (control RV CVF: 1.39 ± 0.25% vs. 4-wk PAB: 4.18 ± 0.87%). RV end-diastolic pressure was unchanged at 2 wk, but increased until 4 wk after PAB. RV fibroblasts isolated after 2-wk PAB had no changes in either insoluble collagen or SPARC expression; however, increases in insoluble collagen and in levels of SPARC were detected in RV fibroblasts from 4-wk PAB. Therefore, the time course of PO-induced RV hypertrophy differs significantly from myocardial fibrosis and diastolic dysfunction. These temporal differences appear dependent on changes in fibroblast function.
Baicu, Catalin F.; Li, Jiayu; Zhang, Yuhua; Kasiganesan, Harinath; Cooper, George; Zile, Michael R.
2012-01-01
Myocardial fibrillar collagen is considered an important determinant of increased ventricular stiffness in pressure-overload (PO)-induced cardiac hypertrophy. Chronic PO was created in feline right ventricles (RV) by pulmonary artery banding (PAB) to define the time course of changes in fibrillar collagen content after PO using a nonrodent model and to determine whether this time course was dependent on changes in fibroblast function. Total, soluble, and insoluble collagen (hydroxyproline), collagen volume fraction (CVF), and RV end-diastolic pressure were assessed 2 days and 1, 2, 4, and 10 wk following PAB. Fibroblast function was assessed by quantitating the product of postsynthetic processing, insoluble collagen, and levels of SPARC (secreted protein acidic and rich in cysteine), a protein that affects procollagen processing. RV hypertrophic growth was complete 2 wk after PAB. Changes in RV collagen content did not follow the same time course. Two weeks after PAB, there were elevations in total collagen (control RV: 8.84 ± 1.03 mg/g vs. 2-wk PAB: 11.50 ± 0.78 mg/g); however, increased insoluble fibrillar collagen, as measured by CVF, was not detected until 4 wk after PAB (control RV CVF: 1.39 ± 0.25% vs. 4-wk PAB: 4.18 ± 0.87%). RV end-diastolic pressure was unchanged at 2 wk, but increased until 4 wk after PAB. RV fibroblasts isolated after 2-wk PAB had no changes in either insoluble collagen or SPARC expression; however, increases in insoluble collagen and in levels of SPARC were detected in RV fibroblasts from 4-wk PAB. Therefore, the time course of PO-induced RV hypertrophy differs significantly from myocardial fibrosis and diastolic dysfunction. These temporal differences appear dependent on changes in fibroblast function. PMID:22942178
The effect of inlet boundary layer thickness on the flow within an annular S-shaped duct
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sonoda, T.; Arima, T.; Oana, M.
1999-07-01
Experimental and numerical investigations were carried out to gain a better understanding of the flow characteristics within an annular S-shaped duct, including the effect of the inlet boundary layer (IBL) on the flow. A duct with six struts and the geometry as that used to connect compressor spools on the experimental small two-spool turbofan engine was investigated. A curved downstream annular passage with similar meridional flow path geometry to that of the centrifugal compressor has been fitted at the exit of S-shaped duct. Two types of the IBL (i.e., thin and thick IBL) were used. Results showed that large differencesmore » of flow patterns were observed at the S-shaped duct exit between two types of IBL, though the value of net total pressure loss has not been remarkably changed. According to overall total pressure loss, which includes the IBL loss, the total pressure loss was greatly increased near the hub as compared to that for a thin one. For the thick IBL, a vortex pair related to the hub-side horseshoe vortex and the separated flow found at the strut trailing edge has been clearly captured in the form of the total pressure loss contours and secondary flow vectors, experimentally and numerically. The high-pressure loss regions on either side of the strut wake near the hub may act on a downstream compressor performance. There is a much-distorted three-dimensional flow patterns at the exit of S-shaped duct. This means that the aerodynamic sensitivity of S-shaped duct to the IBL thickness is very high. Therefore, sufficient care is needed to design not only downstream aerodynamic components (for example, centrifugal impeller) but also upstream aerodynamic components (LPC OGV).« less
Dencker, Magnus; Danielson, Anton; Karlsson, Magnus K; Wollmer, Per; Andersen, Lars B; Thorsson, Ola
2017-04-01
The aim of the study was to assess possible relationships between adipocyte fatty acid-binding protein (FABP4) and total body fat (TBF), abdominal fat, body fat distribution, aerobic fitness, blood pressure, cardiac dimensions and the increase in body fat over 2 years in a community sample of children. A cross-sectional study was used in a community sample of 170 (92 boys and 78 girls) children aged 8-11 years. TBF and abdominal fat (AFM) were measured by dual-energy X-ray absorptiometry (DXA). TBF was also expressed as percentage of total body mass (BF%), and body fat distribution was calculated as AFM/TBF. Maximal oxygen uptake (VO2PEAK) was assessed by indirect calorimetry during a maximal exercise test and scaled to body mass. Systolic and diastolic blood pressure (SBP and DBP) and pulse pressure (PP) were measured. Echocardiography was performed. Left atrial (LA) size was measured, and left ventricular mass (LVM) was calculated. A follow-up DXA scan was available in 152 children (84 boys and 68 girls). Frozen serum samples were analyzed for FABP4. Partial correlations, with adjustment for sex, between FABP4 vs. ln TBF, ln BF%, ln AFM, AFM/TBF and VO2PEAK were (r=0.69, 0.68, 0.69, 0.49 and -0.39, p<0.05 for all). Moreover, SBP, PP, LVM and LA were also weakly correlated with FABP4 (r=0.23, 0.22, 0.28 and 0.21, p<0.05 for all). Correlations between FABP4 vs. increase in TBF and AFM over 2 years were 0.29 and 0.26, p<0.05, for both. (Increase in percent body fat or change in fat distribution were not correlated.) Conclusions: Findings from this community-based cohort of young children show that increased body fat and abdominal fat, more abdominal body fat distribution, low fitness, more LVM and increased LA, increased SBP and PP were all associated with increased levels of FABP4. Increase in TBF and abdominal fat over 2 years were also associated with increased levels of FABP4.
Pahlow, M; van Oel, P R; Mekonnen, M M; Hoekstra, A Y
2015-12-01
As aquaculture becomes more important for feeding the growing world population, so too do the required natural resources needed to produce aquaculture feed. While there is potential to replace fish meal and fish oil with terrestrial feed ingredients, it is important to understand both the positive and negative implications of such a development. The use of feed with a large proportion of terrestrial feed may reduce the pressure on fisheries to provide feed for fish, but at the same time it may significantly increase the pressure on freshwater resources, due to water consumption and pollution in crop production for aquafeed. Here the green, blue and gray water footprint of cultured fish and crustaceans related to the production of commercial feed for the year 2008 has been determined for the major farmed species, representing 88% of total fed production. The green, blue and gray production-weighted average feed water footprints of fish and crustaceans fed commercial aquafeed are estimated at 1629 m3/t, 179 m3/t and 166 m3/t, respectively. The estimated global total water footprint of commercial aquafeed was 31-35 km3 in 2008. The top five contributors to the total water footprint of commercial feed are Nile tilapia, Grass carp, Whiteleg shrimp, Common carp and Atlantic salmon, which together have a water footprint of 18.2 km3. An analysis of alternative diets revealed that the replacement of fish meal and fish oil with terrestrial feed ingredients may further increase pressure on freshwater resources. At the same time economic consumptive water productivity may be reduced, especially for carnivorous species. The results of the present study show that, for the aquaculture sector to grow sustainably, freshwater consumption and pollution due to aquafeed need to be taken into account. Copyright © 2015. Published by Elsevier B.V.
Double-lumen tubes and auto-PEEP during one-lung ventilation.
Spaeth, J; Ott, M; Karzai, W; Grimm, A; Wirth, S; Schumann, S; Loop, T
2016-01-01
Double-lumen tubes (DLT) are routinely used to enable one-lung-ventilation (OLV) during thoracic anaesthesia. The flow-dependent resistance of the DLT's bronchial limb may be high as a result of its narrow inner diameter and length, and thus potentially contribute to an unintended increase in positive end-expiratory pressure (auto-PEEP). We therefore studied the impact of adult sized DLTs on the dynamic auto-PEEP during OLV. In this prospective clinical study, dynamic auto-PEEP was determined in 72 patients undergoing thoracic surgery, with right- and left-sided DLTs of various sizes. During OLV, air trapping was provoked by increasing inspiration to expiration ratio from 1:2 to 2:1 (five steps). Based on measured flow rate, airway pressure (Paw) and bronchial pressure (Pbronch), the pressure gradient across the DLT (ΔPDLT) and the total auto-PEEP in the respiratory system (i.e. the lungs, the DLT and the ventilator circuit) were determined. Subsequently the DLT's share in total auto-PEEP was calculated. ΔPDLT was 2.3 (0.7) cm H2O over the entire breathing cycle. At the shortest expiratory time the mean total auto-PEEP was 2.9 (1.5) cm H2O (range 0-5.9 cm H2O). The DLT caused 27 to 31% of the total auto-PEEP. Size and side of the DLT's bronchial limb did not impact auto-PEEP significantly. Although the DLT contributes to the overall auto-PEEP, its contribution is small and independent of size and side of the DLT's bronchial limb. The choice of DLT does not influence the risk of auto-PEEP during OLV to a clinically relevant extent. DRKS00005648. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Segmental microvascular permeability in ischemia-reperfusion injury in rat lung.
Khimenko, P L; Taylor, A E
1999-06-01
Segmental microvascular permeabilities were measured using pre- and postalveolar vessel capillary filtration coefficient (Kfc) values (ml. min-1. cmH2O-1. 100 g-1) in isolated rat lungs subjected to ischemia-reperfusion (I/R). Total Kfc values measured in flowing and nonflowing lungs were highly correlated (r = 0.98, P < 0.0001). Kfc values were then measured in another group of lungs under no-flow conditions when airway pressure was increased to 20 cmH2O and either the arterial or venous pressure was elevated to 7-8 cmH2O to measure the prealveolar and postalveolar Kfc values. Control total and postalveolar Kfc values were 0.0225 +/- 0.001 and 0.0219 +/- 0.001 ml. min-1. cmH2O-1. 100 g-1, respectively, and the prealveolar permeability was extremely small (0.00003 +/- 0.00005 ml. min-1. cmH2O-1. 100 g-1). Kfc values were again made in nonflowing lungs that had been subjected to 45 min of ischemia followed by 30 min of reperfusion. After I/R, the total membrane Kfc increased 10-fold to 0.2597 +/- 0.006 ml. min-1. cmH2O-1. 100 g-1, the prealveolar Kfc increased to 0.0677 +/- 0.003 ml. min-1. cmH2O-1. 100 g-1, and the postalveolar Kfc increased to 0.1354 +/- 0.008 ml. min-1. cmH2O-1. 100 g-1 (P < 0.05 for all I/R values). These data indicate that normal solvent microvascular permeability was predominantly postalveolar, and after I/R damage, the postalveolar (venular) permeability comprised 52% of the total, whereas the prealveolar and alveolar vessels comprised only 27 and 23%, respectively, of the total Kfc.
NASA Astrophysics Data System (ADS)
Sang, Lina; Gutiérrez, Joffre; Cai, Chuanbing; Dou, Shixue; Wang, Xiaolin
2018-07-01
We report on the effect of in situ hydrostatic pressure on the enhancement of the in-magnetic-field critical current density parallel to the crystallographic c-axis and vortex pinning in epitaxial Y(Dy0.5)Ba2Cu3O7‑δ coated conductors prepared by metal organic deposition. Our results show that in situ hydrostatic pressure greatly enhances the critical current density at high fields and high temperatures. At 80 K and 5 T we observe a ten-fold increase in the critical current density under the pressure of 1.2 GPa, and the irreversibility line is shifted to higher fields without changing the critical temperature. The normalized magnetic relaxation rate shows that vortex creep rates are strongly suppressed due to applied pressure, and the pinning energy is significantly increased based on the collective creep theory. After releasing the pressure, we recover the original superconducting properties. Therefore, we speculate that the in situ hydrostatic pressure exerted on the coated conductor enhances the pinning of existing extended defects. This is totally different from what has been observed in REBa2Cu3O7‑δ melt-textured crystals, where the effect of pressure generates point-like defects.
A comparison of cleat types during two football-specific tasks on FieldTurf.
Queen, R M; Charnock, B L; Garrett, W E; Hardaker, W M; Sims, E L; Moorman, C T
2008-04-01
To examine the effect of different cleat plate configurations on plantar pressure during two tasks. Thirty-six athletes ran an agility course 5 times while wearing 4 different types of Nike Vitoria cleats: (1) bladed, (2) elliptical firm ground, (3) hard ground and (4) turf. Plantar pressure data were recorded during a side cut and a cross cut using Pedar-X insoles. Controlled laboratory study No history of lower extremity injury in the past 6 months, no previous foot or ankle surgery, not currently wearing foot orthotics and play a cleated sport at least twice a week. Total foot contact time, contact area, maximum force, peak pressure and the force-time integral (FTI) in the medial, middle and lateral regions of the forefoot were collected. A 1x4 ANOVA (alpha = 0.05) was performed on each dependent variable. A Bonferroni adjustment was conducted (alpha = 0.008). In the cross cut task, statistical differences between cleats were observed in three variables: total foot peak pressure, lateral forefoot FTI, and lateral forefoot normalised maximum force. In the side cut task, statistical differences between cleats were observed in 4 variables: total foot peak pressure, the medial and middle forefoot FTI, and the medial and middle forefoot normalised maximum force. Significant differences in forefoot loading patterns existed between cleat types. Based on the results of this study, it might be beneficial to increase the forefoot cushioning in cleats in an attempt to decrease loading in these regions of the foot.
Pavan, L; Casiglia, E; Pauletto, P; Batista, S L; Ginocchio, G; Kwankam, M M; Biasin, R; Mazza, A; Puato, M; Russo, E; Pessina, A C
1997-10-01
To confirm that westernization of dietary habits represents a stimulus for the expression of cardiovascular risk. Three representative age- and sex-matched samples of general populations of three continents were compared cross-sectionally by analysis of variance. In total 1110 subjects aged 22-89 years, divided into three groups (370 from Tanzania and Uganda, 370 from the Amazonian region of Brazil, and 370 from northern Italy; 111 men and 259 women in each group). The blood pressure of Africans eating a low-salt fish and vegetable' diet was lower than those of Brazilians, whose diet was based on cereals and meat, and highly urbanized Italians. The systolic blood pressure was correlated to the body mass index for all three populations, but with age only for the Brazilians and Italians. The total cholesterol level and body mass index, both of which are low among Africans, increased progressively with increasing economic level. Transition from a rural to an urbanized lifestyle is accompanied by a rise in the main cardiovascular risk factors; the present data also show that environmental rather than racial factors have a crucial impact on the risk pattern of populations.
ERIC Educational Resources Information Center
Barnard-Brak, Lucy; Saxon, Terrill F.; Johnson, Heather
2011-01-01
Research suggests that new doctoral graduates face increased publication pressure to achieve tenure: doctoral programs may have also increased this expectation. We examined whether faculty graduating before and after the year 2000 differed significantly in total publications, peer-reviewed publications, and first-authored publications as of the…
3D structural panels : a literature review
John F. Hunt
2004-01-01
The world population has surpassed the 6 billion mark and many of these people live in rapidly developing countries that are and will continue to place increasing pressure on the world's natural fiber resources. The total demand for raw material from the forest for housing, packaging, and for office and home furnishings, to name a few; are increasing. Traditional...
Experimental Studies of Active and Passive Flow Control Techniques Applied in a Twin Air-Intake
Joshi, Shrey; Jindal, Aman; Maurya, Shivam P.; Jain, Anuj
2013-01-01
The flow control in twin air-intakes is necessary to improve the performance characteristics, since the flow traveling through curved and diffused paths becomes complex, especially after merging. The paper presents a comparison between two well-known techniques of flow control: active and passive. It presents an effective design of a vortex generator jet (VGJ) and a vane-type passive vortex generator (VG) and uses them in twin air-intake duct in different combinations to establish their effectiveness in improving the performance characteristics. The VGJ is designed to insert flow from side wall at pitch angle of 90 degrees and 45 degrees. Corotating (parallel) and counterrotating (V-shape) are the configuration of vane type VG. It is observed that VGJ has the potential to change the flow pattern drastically as compared to vane-type VG. While the VGJ is directed perpendicular to the side walls of the air-intake at a pitch angle of 90 degree, static pressure recovery is increased by 7.8% and total pressure loss is reduced by 40.7%, which is the best among all other cases tested for VGJ. For bigger-sized VG attached to the side walls of the air-intake, static pressure recovery is increased by 5.3%, but total pressure loss is reduced by only 4.5% as compared to all other cases of VG. PMID:23935422
Witham, Miles D; Price, Rosemary J G; Struthers, Allan D; Donnan, Peter T; Messow, Claudia-Martina; Ford, Ian; McMurdo, Marion E T
2013-10-14
Observational data link low 25-hydroxyvitamin D levels to both prevalent blood pressure and incident hypertension. No clinical trial has yet examined the effect of vitamin D supplementation in isolated systolic hypertension, the most common pattern of hypertension in older people. To test whether high-dose, intermittent cholecalciferol supplementation lowers blood pressure in older patients with isolated systolic hypertension. Parallel group, double-blind, placebo-controlled randomized trial. Primary care clinics and hospital clinics. Patients 70 years and older with isolated systolic hypertension (supine systolic blood pressure >140 mm Hg and supine diastolic blood pressure <90 mm Hg) and baseline 25-hydroxyvitamin D levels less than 30 ng/mL were randomized into the trial from June 1, 2009, through May 31, 2011. A total of 100,000 U of oral cholecalciferol or matching placebo every 3 months for 1 year. Difference in office blood pressure, 24-hour blood pressure, arterial stiffness, endothelial function, cholesterol level, insulin resistance, and b-type natriuretic peptide level during 12 months. A total of 159 participants were randomized (mean age, 77 years). Mean baseline office systolic blood pressure was 163/78 mm Hg. Mean baseline 25-hydroxyvitamin D level was 18 ng/mL. 25-Hydroxyvitamin D levels increased in the treatment group compared with the placebo group (+8 ng/mL at 1 year, P < .001). No significant treatment effect was seen for mean (95% CI) office blood pressure (−1 [−6 to 4]/−2 [−4 to 1] mm Hg at 3 months and 1 [−2 to 4]/0 [−2 to 2] mm Hg overall treatment effect). No significant treatment effect was evident for any of the secondary outcomes (24-hour blood pressure, arterial stiffness, endothelial function, cholesterol level, glucose level, and walking distance). There was no excess of adverse events in the treatment group, and the total number of falls was nonsignificantly lower in the group receiving vitamin D (36 vs 46, P = .24). Vitamin D supplementation did not improve blood pressure or markers of vascular health in older patients with isolated systolic hypertension. isrctn.org Identifier: ISRCTN92186858.
Interaction of Highly Underexpanded Jets with Simulated Lunar Surfaces
NASA Technical Reports Server (NTRS)
Stitt, Leonard E.
1961-01-01
Pressure distributions and erosion patterns on simulated lunar surfaces (hard and soft) and interference effects between the surface and two representative lunar vehicles (cylindrical and spherical) were obtained with cold-air jets at various descent heights and nozzle total-pressure ratios up to 288,000. Surface pressure distributions were dependent on both nozzle area ratio and, nozzle contour. Peak pressures obtained with a sonic nozzle agreed closely with those predicted theoretically for a near-sonic jet expanding into a vacuum. Short bell-shaped nozzles gave annular pressure distributions; the low center pressure resulted from the coalescence of shocks that originated within the nozzle. The high surface pressures were contained within a circle whose diameter was about 16 throat diameters, regardless of nozzle area ratio or contour. The peak pressure increased rapidly as the vehicle approached the surface; for example, at a descent height of 40 throat diameters the peak pressure was 0.4 percent of the chamber pressure, but increased to 6 percent at 13 throat diameters. The exhaust jet eroded a circular concave hole in white sand at descent heights from about 200 to 600 throat diameters. The hole diameter was about 225 throat diameters, while the depth was approximately 60 throat diameters. The sand particles, which formed a conical sheet at a semivertex angle of 50 deg, appeared to follow a ballistic trajectory and at no time struck the vehicle. An increase in pressure was measured on the base of the cylindrical lunar vehicle when it approached to within 14 throat diameters of the hard, flat surface. No interference effects were noted between the spherical model and the surface to descent heights as low as 8 throat diameters.
NASA Astrophysics Data System (ADS)
Queirós, Rui P.; Rainho, Daniel; Santos, Mauro D.; Fidalgo, Liliana G.; Delgadillo, Ivonne; Saraiva, Jorge A.
2015-01-01
This study evaluated high pressure processing (P1 - 400 MPa/5 min; P2 - 550 MPa/2 min) and thermal pasteurization (TP - 70°C/30 s) effects on sweet cherry juice's microbiological and physicochemical parameters, during four weeks of refrigerated storage. All treatments reduced the microbiological load to undetectable levels not affecting total soluble solids and titratable acidity. The pH increased with all treatments, however, it decreased during storage. Phenols were differently affected: TP increased them by 6%, P1 had no effect while P2 decreased them by 11%. During storage, phenols in control and TP samples decreased by 26% and 20%, P1 samples decreased them by 11% whereas P2 showed no variation. TP had no effect on anthocyanins, while pressure treatments increased them by 8%. Anthocyanins decreased during storage, particularly in the control and P1 (decreasing 41%). All treatments had no effect on antioxidant activity until the 14th day, thereafter high pressure processing samples showed the highest antioxidant activity.
Blood Pressure and Arterial Load After Transcatheter Aortic Valve Replacement for Aortic Stenosis.
Lindman, Brian R; Otto, Catherine M; Douglas, Pamela S; Hahn, Rebecca T; Elmariah, Sammy; Weissman, Neil J; Stewart, William J; Ayele, Girma M; Zhang, Feifan; Zajarias, Alan; Maniar, Hersh S; Jilaihawi, Hasan; Blackstone, Eugene; Chinnakondepalli, Khaja M; Tuzcu, E Murat; Leon, Martin B; Pibarot, Philippe
2017-07-01
After aortic valve replacement, left ventricular afterload is often characterized by the residual valve obstruction. Our objective was to determine whether higher systemic arterial afterload-as reflected in blood pressure, pulsatile and resistive load-is associated with adverse clinical outcomes after transcatheter aortic valve replacement (TAVR). Total, pulsatile, and resistive arterial load were measured in 2141 patients with severe aortic stenosis treated with TAVR in the PARTNER I trial (Placement of Aortic Transcatheter Valve) who had systolic blood pressure (SBP) and an echocardiogram obtained 30 days after TAVR. The primary end point was 30-day to 1-year all-cause mortality. Lower SBP at 30 days after TAVR was associated with higher mortality (20.0% for SBP 100-129 mm Hg versus 12.0% for SBP 130-170 mm Hg; P <0.001). This association remained significant after adjustment, was consistent across subgroups, and confirmed in sensitivity analyses. In adjusted models that included SBP, higher total and pulsatile arterial load were associated with increased mortality ( P <0.001 for all), but resistive load was not. Patients with low 30-day SBP and high pulsatile load had a 3-fold higher mortality than those with high 30-day SBP and low pulsatile load (26.1% versus 8.1%; hazard ratio, 3.62; 95% confidence interval, 2.36-5.55). Even after relief of valve obstruction in patients with aortic stenosis, there is an independent association between post-TAVR blood pressure, systemic arterial load, and mortality. Blood pressure goals in patients with a history of aortic stenosis may need to be redefined. Increased pulsatile arterial load, rather than blood pressure, may be a target for adjunctive medical therapy to improve outcomes after TAVR. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00530894. © 2017 American Heart Association, Inc.
NASA Astrophysics Data System (ADS)
Kanikowska, Dominika; Sato, Maki; Iwase, Satoshi; Shimizu, Yuuki; Nishimura, Naoki; Inukai, Yoko; Sugenoya, Junichi
2013-05-01
The effects of environmental temperature on blood pressure and hormones in obese subjects in Japan were compared in two seasons: summer vs winter. Five obese (BMI, 32 ± 5 kg/m2) and five non-obese (BMI, 23 ±3 kg/m2) men participated in this experiment at latitude 35°10' N and longitude 136°57.9' E. The average environmental temperature was 29 ± 1 °C in summer and 3 ± 1 °C in winter. Blood samples were analyzed for leptin, ghrelin, catecholamines, thyroid stimulating hormone (TSH), free thyroxine (fT4), free triiodothyronine (fT3), total cholesterol, triglycerides, insulin and glucose. Blood pressure was measured over the course of 24 h in summer and winter. A Japanese version of the Profile of Mood States (POMS) questionnaire was also administered each season. Systolic and diastolic blood pressures in obese men were significantly higher in winter (lower environmental temperatures) than in summer (higher environmental temperatures). Noradrenaline and dopamine concentrations were also significantly higher at lower environmental temperatures in obese subjects, but ghrelin, TSH, fT3, fT4, insulin and glucose were not significantly different in summer and winter between obese and non-obese subjects. Leptin, total cholesterol and triglyceride concentrations were significantly higher in winter in obese than non-obese men. Results from the POMS questionnaire showed a significant rise in Confusion at lower environmental temperatures (winter) in obese subjects. In this pilot study, increased blood pressure may have been due to increased secretion of noradrenaline in obese men in winter, and the results suggest that blood pressure control in obese men is particularly important in winter.
Frictional heating processes during laboratory earthquakes
NASA Astrophysics Data System (ADS)
Aubry, J.; Passelegue, F. X.; Deldicque, D.; Lahfid, A.; Girault, F.; Pinquier, Y.; Escartin, J.; Schubnel, A.
2017-12-01
Frictional heating during seismic slip plays a crucial role in the dynamic of earthquakes because it controls fault weakening. This study proposes (i) to image frictional heating combining an in-situ carbon thermometer and Raman microspectrometric mapping, (ii) to combine these observations with fault surface roughness and heat production, (iii) to estimate the mechanical energy dissipated during laboratory earthquakes. Laboratory earthquakes were performed in a triaxial oil loading press, at 45, 90 and 180 MPa of confining pressure by using saw-cut samples of Westerly granite. Initial topography of the fault surface was +/- 30 microns. We use a carbon layer as a local temperature tracer on the fault plane and a type K thermocouple to measure temperature approximately 6mm away from the fault surface. The thermocouple measures the bulk temperature of the fault plane while the in-situ carbon thermometer images the temperature production heterogeneity at the micro-scale. Raman microspectrometry on amorphous carbon patch allowed mapping the temperature heterogeneities on the fault surface after sliding overlaid over a few micrometers to the final fault roughness. The maximum temperature achieved during laboratory earthquakes remains high for all experiments but generally increases with the confining pressure. In addition, the melted surface of fault during seismic slip increases drastically with confining pressure. While melting is systematically observed, the strength drop increases with confining pressure. These results suggest that the dynamic friction coefficient is a function of the area of the fault melted during stick-slip. Using the thermocouple, we inverted the heat dissipated during each event. We show that for rough faults under low confining pressure, less than 20% of the total mechanical work is dissipated into heat. The ratio of frictional heating vs. total mechanical work decreases with cumulated slip (i.e. number of events), and decreases with increasing confining pressure and normal stress. Our results suggest that earthquakes are less dispersive under large normal stress. We linked this observation with fault roughness heterogeneity, which also decreases with applied normal stress. Keywords: Frictional heating, stick-slip, carbon, dynamic rupture, fault weakening.
Alcohol consumption and the risk of hypertension in women and men.
Sesso, Howard D; Cook, Nancy R; Buring, Julie E; Manson, JoAnn E; Gaziano, J Michael
2008-04-01
Heavy alcohol intake increases the risk of hypertension, but the relationship between light-to-moderate alcohol consumption and incident hypertension remains controversial. We prospectively followed 28 848 women from the Women's Health Study and 13 455 men from the Physicians' Health Study free of baseline hypertension, cardiovascular disease, and cancer. Self-reported lifestyle and clinical risk factors were collected. In women, total alcohol intake was summed from liquor, red wine, white wine, and beer; men reported total alcohol intake from a single combined question. During 10.9 and 21.8 years of follow-up, 8680 women and 6012 men developed hypertension (defined as new physician diagnosis, antihypertensive treatment, reported systolic blood pressure >or=140 mm Hg, or diastolic blood pressure >or=90 mm Hg). In women, we found a J-shaped association between alcohol intake and hypertension in age- and lifestyle-adjusted models. Adding potential intermediates (body mass index, diabetes, and high cholesterol) attenuated the benefits of alcohol in the light-to-moderate range and strengthened the adverse effects of heavy alcohol intake. Beverage-specific relative risks paralleled those for total alcohol intake. In men, alcohol intake was positively and significantly associated with the risk of hypertension and persisted after multivariate adjustment. Models stratified by baseline systolic blood pressure (<120 versus >or=120 mm Hg) or diastolic blood pressure (<75 versus >or=75 mm Hg) did not alter the relative risks in women and men. In conclusion, light-to-moderate alcohol consumption decreased hypertension risk in women and increased risk in men. The threshold above which alcohol became deleterious for hypertension risk emerged at >or=4 drinks per day in women versus a moderate level of >or=1 drink per day in men.
Trasande, Leonardo; Urbina, Elaine M.; Khoder, Mamdouh; Alghamdi, Mansour; Shabaj, Ibrahim; Alam, Mohammed S.; Harrison, Roy M.; Shamy, Magdy
2017-01-01
Background Polycyclic aromatic hydrocarbons (PAH) are produced by the burning and processing of fuel oils, and have been associated with oxidant stress, insulin resistance and hypertension in adults. Few studies have examined whether adolescents are susceptible to cardiovascular effects of PAHs. Objective To study associations of PAH exposure with blood pressure (BP) and brachial artery distensibility (BAD), an early marker of arterial wall stiffness, in young boys attending three schools in Jeddah, Saudi Arabia in varying proximity to an oil refinery. Methods Air samples collected from the three schools were analyzed for PAHs. PAH metabolites (total hydroxyphenanthrenes and 1-hydroxypyrene) were measured in urine samples from 184 adolescent males, in whom anthropometrics, heart rate, pulse pressure, brachial artery distensibility and blood pressure were measured. Descriptive, bivariate and multivariable analyses were performed to assess relationships of school location and urinary PAH metabolites with cardiovascular measures. Results Total suspended matter was significantly higher (444 ± 143 µg/m3) at the school near the refinery compared to a school located near a ring road (395 ± 65 µg/m3) and a school located away from vehicle traffic (232 ± 137 µg/m3), as were PAHs. Systolic (0.47 SD units, p = 0.006) and diastolic (0.53 SD units, p < 0.001) BP Z-scores were highest at the school near the refinery, with a 4.36-fold increase in prehypertension (p = 0.001), controlling for confounders. No differences in pulse pressure, BAD and heart rate were noted in relationship to school location. Urinary total hydroxyphenanthrenes and 1-hydroxypyrene were not associated with cardiovascular outcomes. Conclusions Proximity to an oil refinery in Saudi Arabia is associated with prehypertension and increases in PAH and particulate matter exposures. Further study including insulin resistance measurements, better control for confounding, and longitudinal measurement is indicated. PMID:25460629
Trasande, Leonardo; Urbina, Elaine M; Khoder, Mamdouh; Alghamdi, Mansour; Shabaj, Ibrahim; Alam, Mohammed S; Harrison, Roy M; Shamy, Magdy
2015-01-01
Polycyclic aromatic hydrocarbons (PAH) are produced by the burning and processing of fuel oils, and have been associated with oxidant stress, insulin resistance and hypertension in adults. Few studies have examined whether adolescents are susceptible to cardiovascular effects of PAHs. To study associations of PAH exposure with blood pressure (BP) and brachial artery distensibility (BAD), an early marker of arterial wall stiffness, in young boys attending three schools in Jeddah, Saudi Arabia in varying proximity to an oil refinery. Air samples collected from the three schools were analyzed for PAHs. PAH metabolites (total hydroxyphenanthrenes and 1-hydroxypyrene) were measured in urine samples from 184 adolescent males, in whom anthropometrics, heart rate, pulse pressure, brachial artery distensibility and blood pressure were measured. Descriptive, bivariate and multivariable analyses were performed to assess relationships of school location and urinary PAH metabolites with cardiovascular measures. Total suspended matter was significantly higher (444 ± 143 μg/m(3)) at the school near the refinery compared to a school located near a ring road (395 ± 65 μg/m(3)) and a school located away from vehicle traffic (232 ± 137 μg/m(3)), as were PAHs. Systolic (0.47 S D units, p = 0.006) and diastolic (0.53 SD units, p < 0.001) BP Z-scores were highest at the school near the refinery, with a 4.36-fold increase in prehypertension (p = 0.001), controlling for confounders. No differences in pulse pressure, BAD and heart rate were noted in relationship to school location. Urinary total hydroxyphenanthrenes and 1-hydroxypyrene were not associated with cardiovascular outcomes. Proximity to an oil refinery in Saudi Arabia is associated with prehypertension and increases in PAH and particulate matter exposures. Further study including insulin resistance measurements, better control for confounding, and longitudinal measurement is indicated. Copyright © 2014 Elsevier Inc. All rights reserved.
Bae, Sanghyuk; Hong, Yun-Chul
2015-02-01
Bisphenol A (BPA) is a chemical used in plastic bottles and inner coating of beverage cans, and its exposure is almost ubiquitous. BPA has been associated with hypertension and decreased heart rate variability in the previous studies. The aim of the present study was to determine whether increased BPA exposure from consumption of canned beverage actually affects blood pressure and heart rate variability. We conducted a randomized crossover trial with noninstitutionalized adults, who were aged ≥60 years and recruited from a local community center. A total of 60 participants visited the study site 3 times, and they were provided the same beverage in 2 glass bottles, 2 cans, or 1 can and 1 glass bottle at a time. The sequence of the beverage was randomized. We then measured urinary BPA concentration, blood pressure, and heart rate variability 2 hours after the consumption of each beverage. The paired t test and mixed model were used to compare the differences. The urinary BPA concentration increased after consuming canned beverages by >1600% compared with that after consuming glass bottled beverages. Systolic blood pressure adjusted for daily variance increased by ≈4.5 mm Hg after consuming 2 canned beverages compared with that after consuming 2 glass bottled beverages, and the difference was statistically significant. The parameters of the heart rate variability did not show statistically significant differences.The present study demonstrated that consuming canned beverage and consequent increase of BPA exposure increase blood pressure acutely. © 2014 American Heart Association, Inc.
Kulchaitanaroaj, Puttarin; Brooks, John M; Ardery, Gail; Newman, Dana; Carter, Barry L
2012-08-01
To compare costs associated with a physician-pharmacist collaborative intervention with costs of usual care. Cost analysis using health care utilization and outcome data from two prospective, cluster-randomized, controlled clinical trials. Eleven community-based medical offices. A total of 496 patients with hypertension; 244 were in the usual care (control) group and 252 were in the intervention group. To compare the costs, we combined cost data from the two trials. Total costs included costs of provider time, laboratory tests, and antihypertensive drugs. Provider time was calculated based on an online survey of intervention pharmacists and the National Ambulatory Medical Care Survey. Cost parameters were taken from the Bureau of Labor Statistics for average wage rates, the Medicare laboratory fee schedule, and a publicly available Web site for drug prices. Total costs were adjusted for patient characteristics. Adjusted total costs were $774.90 in the intervention group and $445.75 in the control group (difference $329.16, p<0.001). In a sensitivity analysis, the difference in adjusted total costs between the two groups ranged from $224.27-515.56. The intervention cost required to have one additional patient achieve blood pressure control within 6 months was $1338.05, determined by the difference in costs divided by the difference in hypertension control rates between the groups ($329.16/24.6%). The cost over 6 months to lower systolic and diastolic blood pressure 1 mm Hg was $36.25 and $94.32, respectively. The physician-pharmacist collaborative intervention increased not only blood pressure control but also the cost of care. Additional research, such as a cost-benefit or a cost-minimization analysis, is needed to assess whether financial savings related to reduced morbidity and mortality achieved from better blood pressure control outweigh the cost of the intervention. © 2012 Pharmacotherapy Publications, Inc. All rights reserved.
Multi-objective optimization design and experimental investigation of centrifugal fan performance
NASA Astrophysics Data System (ADS)
Zhang, Lei; Wang, Songling; Hu, Chenxing; Zhang, Qian
2013-11-01
Current studies of fan performance optimization mainly focus on two aspects: one is to improve the blade profile, and another is only to consider the influence of single impeller structural parameter on fan performance. However, there are few studies on the comprehensive effect of the key parameters such as blade number, exit stagger angle of blade and the impeller outlet width on the fan performance. The G4-73 backward centrifugal fan widely used in power plants is selected as the research object. Based on orthogonal design and BP neural network, a model for predicting the centrifugal fan performance parameters is established, and the maximum relative errors of the total pressure and efficiency are 0.974% and 0.333%, respectively. Multi-objective optimization of total pressure and efficiency of the fan is conducted with genetic algorithm, and the optimum combination of impeller structural parameters is proposed. The optimized parameters of blade number, exit stagger angle of blade and the impeller outlet width are seperately 14, 43.9°, and 21 cm. The experiments on centrifugal fan performance and noise are conducted before and after the installation of the new impeller. The experimental results show that with the new impeller, the total pressure of fan increases significantly in total range of the flow rate, and the fan efficiency is improved when the relative flow is above 75%, also the high efficiency area is broadened. Additionally, in 65% -100% relative flow, the fan noise is reduced. Under the design operating condition, total pressure and efficiency of the fan are improved by 6.91% and 0.5%, respectively. This research sheds light on the considering of comprehensive effect of impeller structrual parameters on fan performance, and a new impeller can be designed to satisfy the engineering demand such as energy-saving, noise reduction or solving air pressure insufficiency for power plants.
Pulmonary Hyperinflation and Left Ventricular Mass
Smith, Benjamin M; Kawut, Steven M.; Bluemke, David A; Basner, Robert C; Gomes, Antoinette S; Hoffman, Eric; Kalhan, Ravi; Lima, João AC; Liu, Chia-Ying; Michos, Erin D; Prince, Martin R; Rabbani, LeRoy; Rabinowitz, Daniel; Shimbo, Daichi; Shea, Steven; Barr, R Graham
2013-01-01
Background Left ventricular (LV) mass is an important predictor of heart failure and cardiovascular mortality, yet determinants of LV mass are incompletely understood. Pulmonary hyperinflation in chronic obstructive pulmonary disease (COPD) may contribute to changes in intrathoracic pressure that increase LV wall stress. We therefore hypothesized that residual lung volume in COPD would be associated with greater LV mass. Methods and results The Multi-Ethnic Study of Atherosclerosis (MESA) COPD Study recruited smokers aged 50–79 years who were free of clinical cardiovascular disease. LV mass was measured by cardiac magnetic resonance. Pulmonary function testing was performed according to guidelines. Regression models were used to adjust for age, sex, body size, blood pressure and other cardiac risk factors. Among 119 MESA COPD Study participants, mean age was 69±6 years, 55% were male and 65% had COPD, mostly of mild or moderate severity. Mean LV mass was 128±34 grams. Residual lung volume was independently associated with greater LV mass (7.2 grams per standard deviation increase in residual volume; 95% CI 2.2 to 12; P=0.004), and was similar in magnitude to that of systolic blood pressure (7.6 grams per standard deviation increase in systolic blood pressure, 95% CI 4.3 to 11 grams; p<0.001). Similar results were observed for LV mass to end-diastolic volume ratio (p=0.02) and with hyperinflation measured as residual volume to total lung capacity ratio (P=0.009). Conclusions Pulmonary hyperinflation, as measured by residual lung volume or residual lung volume to total lung capacity ratio, is associated with greater LV mass. PMID:23493320
Matsumoto, Tomoyuki; Shibanuma, Nao; Takayama, Koji; Sasaki, Hiroshi; Ishida, Kazunari; Matsushita, Takehiko; Kuroda, Ryosuke; Kurosaka, Masahiro
2016-06-01
Appropriate soft tissue balance is essential for the success of total knee arthroplasty (TKA), and assessment with an offset-type tensor provides useful information about the femorotibial (FT) joint. The purpose of the study was to investigate the relationship between intraoperative soft tissue balance and patellar pressure at both medial and lateral sides. Thirty varus-type osteoarthritis patients who received mobile-bearing posterior-stabilized TKAs were enrolled in the study. Using the tensor, soft tissue balance, including joint component gap and varus ligament balance, was recorded at 0°, 10°, 30°, 60°, 90°, 120°, and 135° with patellofemoral (PF) joint reduction and femoral component placement. Following final prostheses implanted with appropriate insert, the medial and lateral patellar pressures were measured at each flexion angle. A simple regression analysis was performed between each patellar pressure, parameter of soft tissue balance, and postoperative flexion angle. Both lateral and medial patellar pressures increased with flexion. The lateral patellar pressure was significantly higher than the medial patellar pressure at 60°, 90°, and 135° of flexion (p<0.05). The lateral patellar pressure inversely correlated with the varus ligament balance at 60° and 90° of flexion (p<0.05). The lateral patellar pressure at 120° and 135° of flexion inversely correlated with the postoperative flexion angle (p<0.05). Soft tissue balance influenced patellar pressure. In particular, a reduced lateral patellar pressure was found at the lateral laxity at flexion, leading to high postoperative flexion angle. III. Copyright © 2016 Elsevier B.V. All rights reserved.
Cost analysis of surgically treated pressure sores stage III and IV.
Filius, A; Damen, T H C; Schuijer-Maaskant, K P; Polinder, S; Hovius, S E R; Walbeehm, E T
2013-11-01
Health-care costs associated with pressure sores are significant and their financial burden is likely to increase even further. The aim of this study was to analyse the direct medical costs of hospital care for surgical treatment of pressure sores stage III and IV. We performed a retrospective chart study of patients who were surgically treated for stage III and IV pressure sores between 2007 and 2010. Volumes of health-care use were obtained for all patients and direct medical costs were subsequently calculated. In addition, we evaluated the effect of location and number of pressure sores on total costs. A total of 52 cases were identified. Average direct medical costs in hospital were €20,957 for the surgical treatment of pressure sores stage III or IV; average direct medical costs for patients with one pressure sore on an extremity (group 1, n = 5) were €30,286, €10,113 for patients with one pressure sore on the trunk (group 2, n = 32) and €40,882 for patients with multiple pressure sores (group 3, n = 15). The additional costs for patients in group 1 and group 3 compared to group 2 were primarily due to longer hospitalisation. The average direct medical costs for surgical treatment of pressure sores stage III and IV were high. Large differences in costs were related to the location and number of pressure sores. Insight into the distribution of these costs allows identification of high-risk patients and enables the development of specific cost-reducing measures. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Kondrashov, Alexey; Vranková, Stanislava; Dovinová, Ima; Ševčík, Rudolf; Parohová, Jana; Barta, Andrej; Pecháňová, Olga; Kovacsová, Maria
2012-01-01
We aimed to perform a chemical analysis of both Alibernet red wine and an alcohol-free Alibernet red wine extract (AWE) and to investigate the effects of AWE on nitric oxide and reactive oxygen species production as well as blood pressure development in normotensive Wistar Kyoto (WKY) and spontaneously hypertensive rats (SHRs). Total antioxidant capacity together with total phenolic and selected mineral content was measured in wine and AWE. Young 6-week-old male WKY and SHR were treated with AWE (24,2 mg/kg/day) for 3 weeks. Total NOS and SOD activities, eNOS and SOD1 protein expressions, and superoxide production were determined in the tissues. Both antioxidant capacity and phenolic content were significantly higher in AWE compared to wine. The AWE increased NOS activity in the left ventricle, aorta, and kidney of SHR, while it did not change NOS activity in WKY rats. Similarly, increased SOD activity in the plasma and left ventricle was observed in SHR only. There were no changes in eNOS and SOD1 expressions. In conclusion, phenolics and minerals included in AWE may contribute directly to increased NOS and SOD activities of SHR. Nevertheless, 3 weeks of AWE treatment failed to affect blood pressure of SHR. PMID:22720118
Measurement of recovery temperature on an airfoil in the Langley 0.3-m transonic cryogenic tunnel
NASA Technical Reports Server (NTRS)
Johnson, C. B.; Adcock, J. B.
1981-01-01
Experimental measurements of recovery temperature were made on an airfoil in the Langley 0.3-m Transonic Cryogenic Tunnel at Mach numbers of 0.60 and 0.84 over a Reynolds number per meter range from about 15,000,000 to about 335,000,000. The measured recovery temperatures were considerably below those associated with ideal-gas ambient temperature wind tunnels. This difference was accentuated as the stagnation pressure increased and the total temperature decreased. A boundary-layer code modified for use with cryogenic nitrogen adequately predicted the measured adiabatic wall temperature at all conditions. A quantitative, on-line assessment of the nonadiabatic condition of a model can be made during the operation of a cryogenic wind tunnel by using a correlation for the adiabatic wall temperature which is only a function of total temperature, total pressure, and local Mach number on the model.
Mikkelsen, Mai Louise Grandsgaard; Ambrus, Rikard; Rasmussen, Rune; Miles, James Edward; Poulsen, Helle Harding; Moltke, Finn Borgbjerg; Eriksen, Thomas
2018-02-08
Vasopressors are frequently used to increase blood pressure in order to ensure sufficient cerebral perfusion and oxygenation (CPO) during hypotensive periods in anaesthetized patients. Efficacy depends both on the vasopressor and anaesthetic protocol used. Propofol-remifentanil total intravenous anaesthesia (TIVA) is common in human anaesthesia, and dexmedetomidine is increasingly used as adjuvant to facilitate better haemodynamic stability and analgesia. Little is known of its interaction with vasopressors and subsequent effects on CPO. This study investigates the CPO response to infusions of norepinephrine and phenylephrine in piglets during propofol-remifentanil and propofol-remifentanil-dexmedetomidine anaesthesia. Sixteen healthy female piglets (25-34 kg) were randomly allocated into a two-arm parallel group design with either normal blood pressure (NBP) or induced low blood pressure (LBP). Anaesthesia was induced with propofol without premedication and maintained with propofol-remifentanil TIVA, and finally supplemented with continuous infusion of dexmedetomidine. Norepinephrine and phenylephrine were infused in consecutive intervention periods before and after addition of dexmedetomidine. Cerebral perfusion measured by laser speckle contrast imaging was related to cerebral oxygenation as measured by an intracerebral Licox probe (partial pressure of oxygen) and transcranial near infrared spectroscopy technology (NIRS) (cerebral oxygen saturation). During propofol-remifentanil anaesthesia, increases in blood pressure by norepinephrine and phenylephrine did not change cerebral perfusion significantly, but cerebral partial pressure of oxygen (Licox) increased following vasopressors in both groups and increases following norepinephrine were significant (NBP: P = 0.04, LBP: P = 0.02). In contrast, cerebral oxygen saturation (NIRS) fell significantly in NBP following phenylephrine (P = 0.003), and following both norepinephrine (P = 0.02) and phenylephrine (P = 0.002) in LBP. Blood pressure increase by both norepinephrine and phenylephrine during propofol-remifentanil-dexmedetomidine anaesthesia was not followed by significant changes in cerebral perfusion. Licox measures increased significantly following both vasopressors in both groups, whereas the decreases in NIRS measures were only significant in the NBP group. Cerebral partial pressure of oxygen measured by Licox increased significantly in concert with the vasopressor induced increases in blood pressure in healthy piglets with both normal and low blood pressure. Cerebral oxygenation assessed by intracerebral Licox and transcranial NIRS showed opposing results to vasopressor infusions.
Skrypnik, Damian; Bogdański, Paweł; Mądry, Edyta; Karolkiewicz, Joanna; Ratajczak, Marzena; Kryściak, Jakub; Pupek-Musialik, Danuta; Walkowiak, Jarosław
2015-01-01
To compare the effects of endurance training with endurance strength training on the anthropometric, body composition, physical capacity, and circulatory parameters in obese women. 44 women with abdominal obesity were randomized into groups A and B, and asked to perform endurance (A) and endurance strength training (B) for 3 months, 3 times/week, for 60 min. Dual-energy X-ray absorptiometry and Graded Exercise Test were performed before and after training. Significant decreases in body mass, BMI, total body fat, total body fat mass, and waist and hip circumference were observed after both types of intervention. Marked increases in total body lean and total body fat-free mass were documented in group B. In both groups, significant increases in peak oxygen uptake, time to exhaustion, maximal work rate, and work rate at ventilatory threshold were accompanied by noticeably decreased resting heart rate, resting systolic blood pressure, and resting and exercise diastolic blood pressure. No significant differences were noticed between groups for the investigated parameters. Our findings demonstrate evidence for a favorable and comparable effect of 3-month endurance and endurance strength training on anthropometric parameters, body composition, physical capacity, and circulatory system function in women with abdominal obesity. © 2015 S. Karger GmbH, Freiburg.
Skrypnik, Damian; Bogdański, Paweł; Mądry, Edyta; Karolkiewicz, Joanna; Ratajczak, Marzena; Kryściak, Jakub; Pupek-Musialik, Danuta; Walkowiak, Jarosław
2015-01-01
Aims To compare the effects of endurance training with endurance strength training on the anthropometric, body composition, physical capacity, and circulatory parameters in obese women. Methods 44 women with abdominal obesity were randomized into groups A and B, and asked to perform endurance (A) and endurance strength training (B) for 3 months, 3 times/week, for 60 min. Dual-energy X-ray absorptiometry and Graded Exercise Test were performed before and after training. Results Significant decreases in body mass, BMI, total body fat, total body fat mass, and waist and hip circumference were observed after both types of intervention. Marked increases in total body lean and total body fat-free mass were documented in group B. In both groups, significant increases in peak oxygen uptake, time to exhaustion, maximal work rate, and work rate at ventilatory threshold were accompanied by noticeably decreased resting heart rate, resting systolic blood pressure, and resting and exercise diastolic blood pressure. No significant differences were noticed between groups for the investigated parameters. Conclusion Our findings demonstrate evidence for a favorable and comparable effect of 3-month endurance and endurance strength training on anthropometric parameters, body composition, physical capacity, and circulatory system function in women with abdominal obesity. PMID:25968470
Zachariah, Justin P; Rong, Jian; Larson, Martin G; Hamburg, Naomi M; Benjamin, Emelia J; Vasan, Ramachandran S; Mitchell, Gary F
2018-02-01
Vascular function varies with age because of physiological and pathological factors. We examined relations of longitudinal change in vascular function with change in metabolic traits. Longitudinal changes in vascular function and metabolic traits were examined in 5779 participants (mean age, 49.8±14.5 years; 54% women) who attended sequential examinations of the Framingham Offspring, Third Generation, and Omni-1 and Omni-2 cohorts. Multivariable regression analysis related changes in vascular measures (dependent variables), including carotid-femoral pulse wave velocity (CFPWV), forward pressure wave amplitude, characteristic impedance, central pulse pressure, and mean arterial pressure (MAP), with change in body mass index, fasting total:high-density lipoprotein cholesterol ratio, serum triglycerides, and blood glucose. Analyses accounted for baseline value of each vascular and metabolic measure, MAP change, and multiple comparisons. On follow-up (mean, 5.9±0.6 years), aortic stiffness (CFPWV, 0.2±1.6 m/s), and pressure pulsatility (forward pressure wave, 1.2±12.4 mm Hg; characteristic impedance, 23±73 dyne×sec/cm 5 ; central pulse pressure, 2.6±14.7 mm Hg; all P <0.0001) increased, whereas MAP fell (-3±10 mm Hg; P <0.0001). Worsening of each metabolic trait was associated with increases in CFPWV and MAP ( P <0.0001 for all associations) and an increase in MAP was associated with an increase in CFPWV. Overall, worsening metabolic traits were associated with worsening aortic stiffness and MAP. Opposite net change in aortic stiffness and MAP suggests that factors other than distending pressure contributed to the observed increase in aortic stiffness. Change in metabolic traits explained a greater proportion of the change in CFPWV and MAP than baseline metabolic values. © 2017 American Heart Association, Inc.
Dynamic calibration of fast-response probes in low-pressure shock tubes
NASA Astrophysics Data System (ADS)
Persico, G.; Gaetani, P.; Guardone, A.
2005-09-01
Shock tube flows resulting from the incomplete burst of the diaphragm are investigated in connection with the dynamic calibration of fast-response pressure probes. As a result of the partial opening of the diaphragm, pressure disturbances are observed past the shock wave and the measured total pressure profile deviates from the envisaged step signal required by the calibration process. Pressure oscillations are generated as the initially normal shock wave diffracts from the diaphragm's orifice and reflects on the shock tube walls, with the lowest local frequency roughly equal to the ratio of the sound speed in the perturbed region to the shock tube diameter. The energy integral of the perturbations decreases with increasing distance from the diaphragm, as the diffracted leading shock and downwind reflections coalesce into a single normal shock. A procedure is proposed to calibrate fast-response pressure probes downwind of a partially opened shock tube diaphragm.
Scaling of angiosperm xylem structure with safety and efficiency.
Hacke, Uwe G; Sperry, John S; Wheeler, James K; Castro, Laura
2006-06-01
We tested the hypothesis that greater cavitation resistance correlates with less total inter-vessel pit area per vessel (the pit area hypothesis) and evaluated a trade-off between cavitation safety and transport efficiency. Fourteen species of diverse growth form (vine, ring- and diffuse-porous tree, shrub) and family affinity were added to published data predominately from the Rosaceae (29 species total). Two types of vulnerability-to-cavitation curves were found. Ring-porous trees and vines showed an abrupt drop in hydraulic conductivity with increasing negative pressure, whereas hydraulic conductivity in diffuse-porous species generally decreased gradually. The ring-porous type curve was not an artifact of the centrifuge method because it was obtained also with the air-injection technique. A safety versus efficiency trade-off was evident when curves were compared across species: for a given pressure, there was a limited range of optimal vulnerability curves. The pit area hypothesis was supported by a strong relationship (r2 = 0.77) between increasing cavitation resistance and diminishing pit membrane area per vessel (A(P)). Small A(P) was associated with small vessel surface area and hence narrow vessel diameter (D) and short vessel length (L)--consistent with an increase in vessel flow resistance with cavitation resistance. This trade-off was amplified at the tissue level by an increase in xylem/vessel area ratio with cavitation resistance. Ring-porous species were more efficient than diffuse-porous species on a vessel basis but not on a xylem basis owing to higher xylem/vessel area ratios in ring-porous anatomy. Across four orders of magnitude, lumen and end-wall resistivities maintained a relatively tight proportionality with a near-optimal mean of 56% of the total vessel resistivity residing in the end-wall. This was consistent with an underlying scaling of L to D(3/2) across species. Pit flow resistance did not increase with cavitation safety, suggesting that cavitation pressure was not related to mean pit membrane porosity.
NASA Technical Reports Server (NTRS)
Jackson, H. Herbert
1955-01-01
A free-flight investigation over a Mach number range from 0.6 to 2.0 has been conducted to determine the longitudinal aerodynamic characteristics and effect of rocket jet on zero-lift drag of 1/5-scale models of two ballistic-type missiles, the Hermes A-3A and A-3B. Models of both types of missiles exhibited very nearly linear normal forces and pitching moments over the angle-of-attack range of 8 deg to -4 deg and Mach number range tested. The centers of pressure for both missiles were not appreciably affected by Mach number over the subsonic range; however, between a Mach number of 1.02 and 1.50 the center of pressure for the A-3A model moved forward 0.34 caliber with increasing Mach number. At a trim angle-of-attack of approximately 30 deg, the A-3A model indicated a total drag coefficient 30% higher than the power-off zero-lift drag over the subsonic Mach number range and 10% higher over the supersonic range. Under the conditions of the present test, and excluding the effect of the jet on base drag, there was no indicated effect of the propulsive jet on the total drag of the A-3A model. The propulsive jet operating at a jet pressure ratio p(sub j)/p(sub o) of 0.8 caused approximately 100% increase in base drag over the Mach number range M = 0.6 to 1.0. This increase in base drag amounts to 15% of the total drag. An underexpanded jet operating at jet pressure ratios corresponding approximately to those of the full-scale missile caused a 22% reduction in base drag at M = 1.55 (p(sub j)/p(sub o) = 1.76) but indicated no change at M = 1.30 (p(sub j)/p(sub o) = 1.43). At M = 1.1 and p(sub j)/p(sub o) = 1.55, the jet caused a 50% increase in base drag.
Ogilvie, R I; Zborowska-Sluis, D
1994-09-01
Chronic rapid right ventricular pacing (RRVP) at 250 beats/min produces low cardiac output (CO) heart failure, marked reduction in total vascular capacitance, and a shift in volume centrally. The effect of converting enzyme inhibition with captopril on cardiac preload was investigated in this model of heart failure. Eight splenectomized dogs were treated with captopril (6.4 mg/kg daily) for 3 days before and 35 +/- 3 days (mean +/- SEM) after continuous RRVP was initiated and the outcome was compared with that of 5 untreated dogs subjected to RRVP for 32 +/- 3 days. Similar reductions in systemic arterial pressure (Psa) and CO and increases in right atrial pressure (Pra) and total peripheral resistance (TPR) were noted in both groups, however, pulmonary capillary wedge pressure (Ppcw) was higher in the untreated group (18.4 +/- 1.6 vs. 12.1 +/- 2.0 mm Hg). Total vascular compliance and capacitance was estimated from mean circulatory filling pressures (Pmcf) at different blood volumes (TBV) during transitory cardiac arrests with acetylcholine (ACh). Pmcf after chronic RRVP was higher in untreated animals (12.6 +/- 1.9 vs. 8.4 +/- 0.7 mm Hg) and compliance was lower (1.9 +/- 0.2 vs. 2.6 +/- 0.2 ml/mm Hg/kg). Total vascular capacitance at a Pmcf of 6 mm Hg was lower in untreated animals (50 +/- 6 vs. 68 +/- 3 ml/kg). Central vascular capacitance was also lower in untreated animals because Ppcw was higher and central blood volume (CBV) as a proportion of TBV was higher (21 +/- 3 vs. 15 +/- 2%). Four of 5 untreated and 1 of 8 treated dogs had severe ascites.(ABSTRACT TRUNCATED AT 250 WORDS)
NASA Astrophysics Data System (ADS)
Thoa, Dao Thi Kim; Loc, Luu Cam
2017-09-01
The effect of both total pressure and hydrogen partial pressure during n-hexane hydro-isomerization over platinum impregnated on HZSM-5 was studied. n-Hexane hydro-isomerization was conducted at atmospheric pressure and 0.7 MPa to observe the influence of total pressure. In order to see the effect of hydrogen partial pressure, the reaction was taken place at different partial pressure of hydrogen varied from 307 hPa to 718 hPa by dilution with nitrogen to keep the total pressure at 0.1 MPa. Physico-chemical characteristics of catalyst were determined by the methods of nitrogen physi-sorption BET, SEM, XRD, TEM, NH3-TPD, TPR, and Hydrogen Pulse Chemi-sorption. Activity of catalyst in the hydro-isomerization of n-hexane was studied in a micro-flow reactor in the temperature range of 225-325 °C; the molar ratio H2/ hydrocarbon: 5.92, concentration of n-hexane: 9.2 mol.%, GHSV 2698 h-1. The obtained catalyst expressed high acid density, good reducing property, high metal dispersion, and good balance between metallic and acidic sites. It is excellent contact for n-hexane hydro-isomerization. At 250 °C, n-hexane conversion and selectivity were as high as 59-76 % and 85-99 %, respectively. It was found that catalytic activity was promoted either by total pressure or hydrogen partial pressure. At total pressure of 0.7 MPa while hydrogen partial pressure of 718 hPa, catalyst produced 63 RON liquid product containing friendly environmental iso-paraffins which is superior blending stock for green gasoline. Hydrogen did not only preserve catalyst actives by depressing hydrocracking and removing coke precursors but also facilitated hydride transfer step in the bi-functional bi-molecular mechanism.
A Low-Pressure Oxygen Storage System for Oxygen Supply in Low-Resource Settings.
Rassool, Roger P; Sobott, Bryn A; Peake, David J; Mutetire, Bagayana S; Moschovis, Peter P; Black, Jim Fp
2017-12-01
Widespread access to medical oxygen would reduce global pneumonia mortality. Oxygen concentrators are one proposed solution, but they have limitations, in particular vulnerability to electricity fluctuations and failure during blackouts. The low-pressure oxygen storage system addresses these limitations in low-resource settings. This study reports testing of the system in Melbourne, Australia, and nonclinical field testing in Mbarara, Uganda. The system included a power-conditioning unit, a standard oxygen concentrator, and an oxygen store. In Melbourne, pressure and flows were monitored during cycles of filling/emptying, with forced voltage fluctuations. The bladders were tested by increasing pressure until they ruptured. In Mbarara, the system was tested by accelerated cycles of filling/emptying and then run on grid power for 30 d. The low-pressure oxygen storage system performed well, including sustaining a pressure approximately twice the standard working pressure before rupture of the outer bag. Flow of 1.2 L/min was continuously maintained to a simulated patient during 30 d on grid power, despite power failures totaling 2.9% of the total time, with durations of 1-176 min (mean 36.2, median 18.5). The low-pressure oxygen storage system was robust and durable, with accelerated testing equivalent to at least 2 y of operation revealing no visible signs of imminent failure. Despite power cuts, the system continuously provided oxygen, equivalent to the treatment of one child, for 30 d under typical power conditions for sub-Saharan Africa. The low-pressure oxygen storage system is ready for clinical field trials. Copyright © 2017 by Daedalus Enterprises.
Myburgh, Caitlynd; Huisman, Hugo W; Mels, Catharina M C
2018-04-01
Oxidative stress has been implicated in the development of hypertension, arterial stiffness and atherosclerosis. Optimal functioning of the enzymatic antioxidant system is central to prevent increased oxidative stress and its consequences. We aimed to investigate the relationships of ambulatory blood pressure and carotid intima-media thickness with enzyme activities of the glutathione cycle in 396 young, black and white South Africans of the African-PREDICT study. Ambulatory blood pressure and carotid intima-media thickness were measured and glutathione peroxidase and glutathione reductase activities were analyzed. Black participants had higher reactive oxygen species (men: p = 0.019; women: borderline p = 0.064) and total glutathione (both p < 0.001), but lower glutathione peroxidase activity and total antioxidant status (all p < 0.001). In black men, ambulatory pulse pressure was negatively associated with glutathione peroxidase activity (R 2 = 0.19; β = -0.25; p = 0.06). Black and white women displayed positive associations of ambulatory systolic blood pressure (black: R 2 = 0.25; β = 0.21; p = 0.048; white: R 2 = 0.44; β = 0.18; p = 0.016) with glutathione reductase activity, whereas white men displayed a positive association of ambulatory pulse pressure with glutathione reductase activity (R 2 = 0.25; β = 0.29; p = 0.01). The lower glutathione peroxidase activity and total antioxidant status, the higher reactive oxygen species, as well as the negative association between ambulatory pulse pressure and glutathione peroxidase activity in the black men suggest that oxidative stress may be associated with early vascular changes in this group. In the other three groups, the positive associations of blood pressure with glutathione reductase activity suggest a possible role for adequate glutathione reductase activity in preventing or delaying the development of hypertension.
The Effect of Ramadan Fasting on Biochemical Parameters in Healthy Thai Subjects.
Ongsara, Sara; Boonpol, Sakulrat; Prompalad, Nussaree; Jeenduang, Nutjaree
2017-09-01
Although, the effect of Ramadan fasting on the risks for Cardiovascular Disease (CVD) has been reported in several studies, the results were inconsistent. In addition, the effect of Ramadan fasting on biochemical parameters in Thai subjects has not been evaluated. The aim of this study was to investigate the effect of Ramadan fasting on anthropometry, blood pressure, Fasting Blood Glucose (FBG), lipid profiles, and body composition in healthy Thai subjects. A total of 65 healthy subjects (21 men and 44 women) aged between 19-24 years were randomly recruited. Anthropometry, blood pressure, FBG, Total Cholesterol (TC), Triglyceride (TG), High Density Lipoprotein-Cholesterol (HDL-C), Low Density Lipoprotein-Cholesterol (LDL-C), and body composition were measured before Ramadan, end of Ramadan and after one month of Ramadan. There were no changes in anthropometry, blood pressure, lipid profiles and body composition in both genders before Ramadan, end of Ramadan and after one month of Ramadan. Nevertheless, FBG levels were significantly increased after one month of Ramadan compared with baseline (5.09±0.50 versus 4.83±0.38 mmol/L, p=0.016, respectively) in women. The Ramadan fasting did not affect the lipid, anthropometric and body composition in healthy Thai subjects. However, the increased FBG levels after one month of Ramadan were observed in women. To improve the favourable biochemical parameters after Ramadan fasting, the lifestyle modifications such as, increased intake of healthy diets and increased physical activity should be recommended.
The Effect of Ramadan Fasting on Biochemical Parameters in Healthy Thai Subjects
Ongsara, Sara; Boonpol, Sakulrat; Prompalad, Nussaree
2017-01-01
Introduction Although, the effect of Ramadan fasting on the risks for Cardiovascular Disease (CVD) has been reported in several studies, the results were inconsistent. In addition, the effect of Ramadan fasting on biochemical parameters in Thai subjects has not been evaluated. Aim The aim of this study was to investigate the effect of Ramadan fasting on anthropometry, blood pressure, Fasting Blood Glucose (FBG), lipid profiles, and body composition in healthy Thai subjects. Materials and Methods A total of 65 healthy subjects (21 men and 44 women) aged between 19-24 years were randomly recruited. Anthropometry, blood pressure, FBG, Total Cholesterol (TC), Triglyceride (TG), High Density Lipoprotein-Cholesterol (HDL-C), Low Density Lipoprotein-Cholesterol (LDL-C), and body composition were measured before Ramadan, end of Ramadan and after one month of Ramadan. Results There were no changes in anthropometry, blood pressure, lipid profiles and body composition in both genders before Ramadan, end of Ramadan and after one month of Ramadan. Nevertheless, FBG levels were significantly increased after one month of Ramadan compared with baseline (5.09±0.50 versus 4.83±0.38 mmol/L, p=0.016, respectively) in women. Conclusion The Ramadan fasting did not affect the lipid, anthropometric and body composition in healthy Thai subjects. However, the increased FBG levels after one month of Ramadan were observed in women. To improve the favourable biochemical parameters after Ramadan fasting, the lifestyle modifications such as, increased intake of healthy diets and increased physical activity should be recommended. PMID:29207694
Liu, Weidong; Sun, Mingbo
2014-01-01
The influence of the in-stream pylon and strut on the performance of scramjet combustor was experimentally and numerically investigated. The experiments were conducted with a direct-connect supersonic model combustor equipped with multiple cavities. The entrance parameter of combustor corresponds to scramjet flight Mach number 4.0 with a total temperature of 947 K. The research results show that, compared with the scramjet combustor without pylon and strut, the wall pressure and the thrust of the scramjet increase due to the improvement of mixing and combustion effect due to the pylon and strut. The total pressure loss caused by the strut is considerable whereas pylon influence is slight. PMID:25254234
A study of 173 nm light emission from discharge cells in plasma display panel
NASA Astrophysics Data System (ADS)
Uhm, Han S.; Choi, Eun H.; Jung, Kyu B.
2005-03-01
Emission properties of the 173nm lights from the electrical discharge cells of the plasma display panel are investigated. The dimer formation and a theoretical model of 173nm emission are presented. It is shown that the diffusion loss of the excited xenon atoms in the metastable level is one of the most important population depreciation factor of excited xenon atoms. The decay time τd of excited atom number increases from zero, reaches its peak, and then decreases to zero, as the gas pressure p increases from zero, agreeing well with experimental data. A simple analytical expression Y of the total emission intensity is described in terms of the diffusion loss df, the three-body collision η, the gas pressure p, and the xenon mole fraction χ. The emission intensity Y of 173nm photon decreases with an increasing value of parameter df. Moreover, the emission intensity Y increases drastically with an increasing value of the gas pressure p and the xenon mole fraction χ. Results from the theoretical model agree remarkably well with experimental data.
The Development of an 8-inch by 8-inch Slotted Tunnel for Mach Numbers up to 1.28
NASA Technical Reports Server (NTRS)
Little, B. H., Jr.; Cubbage, James J., Jr.
1961-01-01
An 8-inch by 8-inch transonic tunnel model with test section slotted on two opposite walls was constructed in which particular emphasis -was given to the development of slot geometry, slot-flow reentry section, and short-diffuser configurations for good test-region flow and minimum total-pressure losses. Center-line static pressures through the test section, wall static pressures through the other parts of the tunnel, and total-pressure distributions at the inlet and exit stations of the diffuser were measured- With a slot length equal to two tunnel heights and 1/14 open-area-ratio slotted walls) a test region one tunnel height in length was obtained in which the deviation from the mean Mach number was less than +/- 0.01 up to Mach number 1.15. With 1/7 open-area-ratio slotted walls, a test region 0.84 tunnel heights in length with deviation less than +/- O.01 was obtained up to Mach number 1.26. Increasing the tunnel diffuser angle from 6.4 to 10 deg. increased pressure loss through the tunnel at Mach number 1.20 from 15 percent to 20 percent of the total pressure. The use of other diffusers with equivalent angles of 10 deg. but contoured so that the initial diffusion angle was less than 10 deg. and the final angle was 200 reduced the losses to as low as 16 percent. A method for changing the test-section Mach number rapidly by controlling the flow through a bypass line from the tunnel settling chamber to the slot-flow plenum chamber of the test section was very effective. The test-section Mach number was reduced approximately 5 percent in 1/8 second by bleeding into the test section a flow of air equal to 2 percent of the mainstream flow and 30 percent in 1/4 second with bleed flow equal to 10 percent of the mainstream flow. The rate of reduction was largely determined by the opening rate of the bleed-flow-control valve.
Li, Xiu-Xia; Tian, Xin; Li, Jian-Rong
2016-06-01
Using thermal processing (TP) treatment (100 ℃, 1-8 min) as a control, the effects of high hydrostatic pressure (HHP, 200-500 MPa, 2.5-20 min) on the microbiological and biochemical characteristics of white shrimp Litopenaeus vannamei were investigated. The results showed that the efficiency of polyphenol oxidase (PPO) inactivation and log reduction of total plate count (TPC) by HHP treatment were all significantly lower than by TP treatment (p < 0.05). The rate of inactivation for TPC and PPO all increased with the increase of HHP pressure and holding time (p < 0.05). The inactivation of PPO was in accordance with a first-order kinetics with the HHP treating time. Hardness of HHP-treated samples at the pressure of 300-500 MPa was higher than TP-treated samples, while the yield loss of HHP treatment was significantly lower than with TP treatment (p < 0.05), long time and high pressure of HHP treatment turned the appearance of shrimps slightly pink. © The Author(s) 2015.
Variation in skin biology to climate in Shanghai, China.
Liu, Xiaoping; Gao, Yanrui; Zhang, Yiyi; Wang, Xuemin
2017-09-01
To explore the relationship between climate and skin condition, and to investigate the variation of skin biology to climatic change. In total, 2005 healthy Chinese volunteers living in Shanghai (aged 13-69 years) were recruited. Transepidermal water loss (TEWL) and SCH were tested on six sites (forehead, cheek, nasolabial, inner forearm, dorsal hand, and palm) by noninvasive devices between January 2005 and December 2012. The corresponding climate data were recorded by local Weather Bureau. TEWL was increased with atmospheric pressure and decreased with temperature, steam pressure, and relative humidity (p < 0.05). SCH was increased with steam pressure and decreased with atmospheric pressure (p < 0.05); there was no obvious trend between SCH and temperature and SCH and relative humidity. To investigate the climate parameters together, we introduced these correlated factors into the multivariate linear regression model which demonstrated that temperature and steam pressure were main factors related to skin biological parameters. At different sites, the effect of climatic factors on skin biology was diverse. Skin biological parameters are associated with climatic factors. Different sites have different sensitivity to climate factors.
Binia, Aristea; Jaeger, Jonathan; Hu, Youyou; Singh, Anurag; Zimmermann, Diane
2015-08-01
To evaluate the efficacy of daily potassium intake on decreasing blood pressure in non-medicated normotensive or hypertensive patients, and to determine the relationship between potassium intake, sodium-to-potassium ratio and reduction in blood pressure. Mixed-effect meta-analyses and meta-regression models. Medline and the references of previous meta-analyses. Randomized controlled trials with potassium supplementation, with blood pressure as the primary outcome, in non-medicated patients. Fifteen randomized controlled trials of potassium supplementation in patients without antihypertensive medication were selected for the meta-analyses (917 patients). Potassium supplementation resulted in reduction of SBP by 4.7 mmHg [95% confidence interval (CI) 2.4-7.0] and DBP by 3.5 mmHg (95% CI 1.3-5.7) in all patients. The effect was found to be greater in hypertensive patients, with a reduction of SBP by 6.8 mmHg (95% CI 4.3-9.3) and DBP by 4.6 mmHg (95% CI 1.8-7.5). Meta-regression analysis showed that both increased daily potassium excretion and decreased sodium-to-potassium ratio were associated with blood pressure reduction (P < 0.05). Increased total daily potassium urinary excretion from 60 to 100 mmol/day and decrease of sodium-to-potassium ratio were shown to be necessary to explain the estimated effect. Potassium supplementation is associated with reduction of blood pressure in patients who are not on antihypertensive medication, and the effect is significant in hypertensive patients. The reduction in blood pressure significantly correlates with decreased daily urinary sodium-to-potassium ratio and increased urinary potassium. Patients with elevated blood pressure may benefit from increased potassium intake along with controlled or decreased sodium intake.
Bonow, R O; Ostrow, H G; Rosing, D R; Cannon, R O; Lipson, L C; Maron, B J; Kent, K M; Bacharach, S L; Green, M V
1983-11-01
To investigate the effects of verapamil on left ventricular systolic and diastolic function in patients with hypertrophic cardiomyopathy, we studied 14 patients at catheterization with a nonimaging scintillation probe before and after serial intravenous infusions of low-, medium-, and high-dose verapamil (total dose 0.17 to 0.72 mg/kg). Percent change in radionuclide stroke counts after verapamil correlated well with percent change in thermodilution stroke volume (r = .87), and changes in diastolic and systolic counts were used to assess relative changes in left ventricular volumes after verapamil. Verapamil produced dose-related increases in end-diastolic counts (19 +/- 9% increase; p less than .001), end-systolic counts (91 +/- 54% increase; p less than .001), and stroke counts (7 +/- 10% increase; p less than .02). This was associated with a decrease in ejection fraction (83 +/- 8% control, 73 +/- 10% verapamil; p less than .001) and, in the 10 patients with left ventricular outflow tract gradients, a reduction in gradient (62 +/- 27 mm Hg control, 32 +/- 35 mm Hg verapamil; p less than .01). The end-systolic pressure-volume relation was shifted downward and rightward in all patients, suggesting a negative inotropic effect. In 10 patients, left ventricular pressure-volume loops were constructed with simultaneous micromanometer pressure recordings and the radionuclide time-activity curve. In five patients, verapamil shifted the diastolic pressure-volume curve downward and rightward, demonstrating improved pressure-volume relations despite the negative inotropic effect, and also increased the peak rate of rapid diastolic filling. In the other five patients, the diastolic pressure-volume relation was unaltered by verapamil, and increased end-diastolic volumes occurred at higher end-diastolic pressures; in these patients, the peak rate of left ventricular diastolic filling was not changed by verapamil. The negative inotropic effects of intravenous verapamil are potentially beneficial in patients with hypertrophic cardiomyopathy by decreasing left ventricular contractile function and increasing left ventricular volume. Verapamil also enhances left ventricular diastolic filling and improves diastolic pressure-volume relations in some patients despite its negative inotropic effect.
Feger, Mark A; Hertel, Jay
2016-08-01
Rehabilitation is ineffective at restoring normal gait in chronic ankle instability patients. Our purpose was to determine if a novel gait-training device could decrease plantar pressure on the lateral column of the foot in chronic ankle instability patients. Ten chronic ankle instability patients completed 30s trials of baseline and gait-training walking at a self-selected pace while in-shoe plantar pressure and surface electromyography were recorded from their anterior tibialis, peroneus longus, medial gastrocnemius, and gluteus medius. The gait-training device applied a medially-directed force to the lower leg via elastic bands during the entire gait cycle. Plantar pressure measures of the entire foot and 9 specific regions of the foot as well as surface electromyography root mean square areas were compared between the baseline and gait-training conditions using paired t-tests with a priori level of significance of p≤0.05. The gait-training device decreased pressure time integrals and peak pressures in the lateral midfoot (p=0.003 and p=0.003) and lateral forefoot (p=0.023 and p=0.005), and increased pressure time integrals and peak pressures for the total foot (p=0.030 and p=0.017) and hallux (p=0.005 and p=0.002). The center of pressure was shifted medially during the entire stance phase (p<0.003 for all comparisons) due to increased peroneus longus activity prior to (p=0.002) and following initial contact (p=0.002). The gait-training device decreased pressure on the lateral column of the foot and increased peroneus longus muscle activity. Future research should analyze the efficacy of the gait-training device during gait retraining for chronic ankle instability. Copyright © 2016 Elsevier Ltd. All rights reserved.
Performance Analysis of Abrasive Waterjet Machining Process at Low Pressure
NASA Astrophysics Data System (ADS)
Murugan, M.; Gebremariam, MA; Hamedon, Z.; Azhari, A.
2018-03-01
Normally, a commercial waterjet cutting machine can generate water pressure up to 600 MPa. This range of pressure is used to machine a wide variety of materials. Hence, the price of waterjet cutting machine is expensive. Therefore, there is a need to develop a low cost waterjet machine in order to make the technology more accessible for the masses. Due to its low cost, such machines may only be able to generate water pressure at a much reduced rate. The present study attempts to investigate the performance of abrasive water jet machining process at low cutting pressure using self-developed low cost waterjet machine. It aims to study the feasibility of machining various materials at low pressure which later can aid in further development of an effective low cost water jet machine. A total of three different materials were machined at a low pressure of 34 MPa. The materials are mild steel, aluminium alloy 6061 and plastics Delrin®. Furthermore, a traverse rate was varied between 1 to 3 mm/min. The study on cutting performance at low pressure for different materials was conducted in terms of depth penetration, kerf taper ratio and surface roughness. It was found that all samples were able to be machined at low cutting pressure with varied qualities. Also, the depth of penetration decreases with an increase in the traverse rate. Meanwhile, the surface roughness and kerf taper ratio increase with an increase in the traverse rate. It can be concluded that a low cost waterjet machine with a much reduced rate of water pressure can be successfully used for machining certain materials with acceptable qualities.
Skrzypczak, M; Szwed, A
2005-01-01
The main purpose of this paper is to describe the variability of the body mass index (BMI) and selected physiological parameters (serum glucose, total serum cholesterol, systolic and diastolic blood pressure) in women before and after menopause. The empirical basis for the assessment is the material obtained in cross-sectional studies carried out in the years 1998-2001 in a group of 2204 women aged 35-65 years, residents of the Wielkopolska region, Poland. The results indicate that hormonal changes taking place in the climacterium bring about an increase in the BMI. It was observed that women receiving Hormone Replacement Therapy in the perimenopause had BMI significantly lower than naturally menopausal women. Increased levels of total serum cholesterol and blood glucose were recorded. The trend has a stronger relation with the age of the subjects than with the character of the menopause. The systolic and diastolic blood pressure values were also found to increase significantly after the menopause, but no relationship with the type of menopause was found.
Ion beams in multi-species plasmas
NASA Astrophysics Data System (ADS)
Aguirre, E. M.; Scime, E. E.; Good, T. N.
2018-04-01
Argon and xenon ion velocity distribution functions are measured in Ar-He, Ar-Xe, and Xe-He expanding helicon plasmas to determine if ion beam velocity is enhanced by the presence of lighter ions. Contrary to observations in mixed gas sheath experiments, we find that adding a lighter ion does not increase the ion beam speed. The predominant effect is a reduction of ion beam velocity consistent with increased drag arising from increased gas pressure under all conditions: constant total gas pressure, equal plasma densities of different ions, and very different plasma densities of different ions. These results suggest that the physics responsible for the acceleration of multiple ion species in simple sheaths is not responsible for the ion acceleration observed in expanding helicon plasmas.
Ríos-González, Blanca Estela; Ibarra-Cortés, Bertha; Ramírez-López, Guadalupe; Sánchez-Corona, José; Magaña-Torres, María Teresa
2014-01-01
Hypertension and dyslipidemia exhibit an important clinical relationship because an increase in blood lipids yields an increase in blood pressure (BP). We analyzed the associations of seven polymorphisms of genes involved in lipid metabolism (APOA5 rs3135506, APOB rs1042031, FABP2 rs1799883, LDLR rs5925, LIPC rs1800588, LPL rs328, and MTTP rs1800591) with blood pressure and lipid values in Mexican hypertensive (HT) patients. A total of 160 HT patients and 160 normotensive individuals were included. Genotyping was performed through PCR-RFLP, PCR-AIRS, and sequencing. The results showed significant associations in the HT group and HT subgroups classified as normolipemic and hyperlipemic. The alleles FABP2 p.55T, LIPC -514T, and MTTP -493T were associated with elevated systolic BP. Five alleles were associated with lipids. LPL p.474X and FABP2 p.55T were associated with decreased total cholesterol and LDL-C, respectively; APOA5 p.19W with increased HDL-C; APOA5 p.19W and FABP2 p.55T with increased triglycerides; and APOB p.4181K and LDLR c.1959T with decreased triglycerides. The APOB p.E4181K polymorphism increases the risk for HT (OR = 1.85, 95% CI: 1.17-2.93; P = 0.001) under the dominant model. These findings indicate that polymorphisms of lipid metabolism genes modify systolic BP and lipid levels and may be important in the development of essential hypertension and dyslipidemia in Mexican HT patients.
Ríos-González, Blanca Estela; Ibarra-Cortés, Bertha; Ramírez-López, Guadalupe; Sánchez-Corona, José; Magaña-Torres, María Teresa
2014-01-01
Hypertension and dyslipidemia exhibit an important clinical relationship because an increase in blood lipids yields an increase in blood pressure (BP). We analyzed the associations of seven polymorphisms of genes involved in lipid metabolism (APOA5 rs3135506, APOB rs1042031, FABP2 rs1799883, LDLR rs5925, LIPC rs1800588, LPL rs328, and MTTP rs1800591) with blood pressure and lipid values in Mexican hypertensive (HT) patients. A total of 160 HT patients and 160 normotensive individuals were included. Genotyping was performed through PCR-RFLP, PCR-AIRS, and sequencing. The results showed significant associations in the HT group and HT subgroups classified as normolipemic and hyperlipemic. The alleles FABP2 p.55T, LIPC −514T, and MTTP −493T were associated with elevated systolic BP. Five alleles were associated with lipids. LPL p.474X and FABP2 p.55T were associated with decreased total cholesterol and LDL-C, respectively; APOA5 p.19W with increased HDL-C; APOA5 p.19W and FABP2 p.55T with increased triglycerides; and APOB p.4181K and LDLR c.1959T with decreased triglycerides. The APOB p.E4181K polymorphism increases the risk for HT (OR = 1.85, 95% CI: 1.17–2.93; P = 0.001) under the dominant model. These findings indicate that polymorphisms of lipid metabolism genes modify systolic BP and lipid levels and may be important in the development of essential hypertension and dyslipidemia in Mexican HT patients. PMID:25587205
Thermodynamic evaluation of transonic compressor rotors using the finite volume approach
NASA Technical Reports Server (NTRS)
Moore, J.; Nicholson, S.; Moore, J. G.
1985-01-01
Research at NASA Lewis Research Center gave the opportunity to incorporate new control volumes in the Denton 3-D finite-volume time marching code. For duct flows, the new control volumes require no transverse smoothing and this allows calculations with large transverse gradients in properties without significant numerical total pressure losses. Possibilities for improving the Denton code to obtain better distributions of properties through shocks were demonstrated. Much better total pressure distributions through shocks are obtained when the interpolated effective pressure, needed to stabilize the solution procedure, is used to calculate the total pressure. This simple change largely eliminates the undershoot in total pressure down-stream of a shock. Overshoots and undershoots in total pressure can then be further reduced by a factor of 10 by adopting the effective density method, rather than the effective pressure method. Use of a Mach number dependent interpolation scheme for pressure then removes the overshoot in static pressure downstream of a shock. The stability of interpolation schemes used for the calculation of effective density is analyzed and a Mach number dependent scheme is developed, combining the advantages of the correct perfect gas equation for subsonic flow with the stability of 2-point and 3-point interpolation schemes for supersonic flow.
T700 Blisk and Impeller Manufacturing Process Development Program.
1979-11-01
700(40) Reworked Media Temperature - 790 F Average Media Pressure - 200 psi Total Cycles (Test No. 1) - 40 Total Cycles (Test No. 2) - 20 Total Time...36A(73), - 700(40" Media Temperature - 80F Average Media Pressure - 150 psi Total Cycles - 52 Total Time - 95 Minutes Some difficulty was...61)-36A(73)-700( 4O)Media Temperature - 79OF average Media Pressure - 200 psi Time - 40 cycles - 72 minutes Time - 60 cycles - 109 minutes Time - 80
Measures of total stress-induced blood pressure responses are associated with vascular damage.
Nazzaro, Pietro; Seccia, Teresa; Vulpis, Vito; Schirosi, Gabriella; Serio, Gabriella; Battista, Loredana; Pirrelli, Anna
2005-09-01
The role of cardiovascular reactivity to study hypertension, and the assessment methods, are still controversial. We aimed to verify the association of hypertension and vascular damage with several measures of cardiovascular response. We studied 40 patients with normal-high (132 +/- 1/87 +/- 1 mm Hg) blood pressure (Group 1) and 80 untreated hypertensive subjects. Postischemic forearm vascular resistance (mFVR) served to differentiate hypertensive subjects (142 +/- 2/92 +/- 1 mm Hg v 143 +/- 2/94 +/- 2 mm Hg, P = NS) with a lower (Group 2) and higher (Group 3) hemodynamic index of vascular damage (4.8 +/- .05 v 6.3 +/- .09, P < .001). Reactivity was induced by Stroop (5') and cold pressor (90") tests. We measured muscular contraction and skin conductance as indices of emotional arousal, blood pressure, heart rate, forearm blood flow, and vascular resistance. Reactivity measures included: a) change from baseline, b) residualized score, c) cumulative change from baseline and residualized score, and d) total reactivity as area-under-the-curve (AUC), including changes occurring during baseline and recovery phases. The AUC of systolic blood pressure, diastolic blood pressure, and mFVR progressively increased in the groups (P < .001). Corrections of anthropometric and metabolic confounders were introduced in the Pearson equation between mFVR and reactivity measures. The AUC of SBP, DBP, and forearm blood flow and resistance demonstrated the highest (P < .001) correlation. On multiple regression analysis, AUC of SBP (beta = 0.634) and forearm blood flow (beta = -0.337) were predictive (P < .001) of vascular damage. Total blood pressure stress response, as AUC, including baseline and recovery phases, was significantly better associated with hypertension and vascular damage than the other reactivity measures studied.
Javanmard, F; Azadbakht, M; Pourmoradi, M
2016-01-01
In this study, the role of hydrostatic pressure on staurosporine-induced neural differentiation in mouse bone marrow mesenchymal stem cells were investigated. The cells were cultured in treatment medium containing 100 nM of staurosporine for 4 hours; then the cells were affected by hydrostatic pressure (0, 25,50, 100 mmHg). The percentage of cell viability by trypan blue staining and the percentage of cell death by Hoechst/PI differential staining were assessed. We obtained the total neurite length. Expression of β-tubulin III and GFAP (Glial fibrillary acidic protein) proteins were also analyzed by immunocytochemistry. The percentage of cell viability in treatments decreased relative to the increase in hydrostatic pressure and time (p Keywords: bone marrow mesenchymal stem cell, hydrostatic pressure, immunocytochemistry, neural differentiation, neurite length, cell differentiation.
NASA Astrophysics Data System (ADS)
Katragkou, E.; Wilhelm, S.; Arnold, F.; Wilson, C.
2004-01-01
Gaseous S(VI) (SO3 + H2SO4) has been measured by chemical ionization mass spectrometry (CIMS) in the simulated internal flow of an aircraft gas turbine in a test rig at ground level during the PartEmis 2002 campaign. Building on S(VI) and calculated total sulfur ST the abundance ratio ɛ = S(VI)/ST was determined. The measurements to be reported here were made at two sampling points, for two engine test conditions representative of old and modern aircraft cruise and for a fuel sulfur content FSC = 1270 ppm. For both cruise conditions the measured ɛ increased with increasing exhaust age from the high pressure to the low pressure stage. For each pressure stage ɛ was higher in the modern cruise condition. The maximum ɛ (2.3 +/- 1.2%) was obtained for modern cruise and the low pressure stage. Our present data suggest that modern engines have a somewhat higher conversion efficiencies than old engines.
Magnetic properties of solid oxygen under pressure (Review Article)
NASA Astrophysics Data System (ADS)
Freiman, Yu. A.
2015-11-01
Solid oxygen is a unique crystal combining properties of a simple molecular solid and a magnet. Unlike ordinary magnets, the exchange interaction in solid oxygen acts on a background of weak Van der Waals forces, providing a significant part of the total lattice energy. Therefore, the magnetic and lattice properties of solid oxygen are very closely related. This manifests itself in a very rich phase diagram and numerous anomalies of thermal, magnetic and optical properties. Low-temperature low-pressure α-O2 is a two-sublattice collinear Neel antiferromagnet. At a pressure of ˜6 GPa, α-O2 is transformed into δ-O2, in which three different magnetic structures are realized upon increasing temperature. At ˜8 GPa δ-O2 is transformed into ɛ-O2. In this transition, O2 molecules combine into four-molecule clusters (O2)4. This transformation is accompanied by a magnetic collapse. This review describes the evolution of the magnetic structure with increasing pressure, and analyzes the causes behind this behavior.
Beyond sixfold coordinated Si in SiO2 glass at ultrahigh pressures
Prescher, Clemens; Prakapenka, Vitali B.; Stefanski, Johannes; Jahn, Sandro; Skinner, Lawrie B.; Wang, Yanbin
2017-01-01
We investigated the structure of SiO2 glass up to 172 GPa using high-energy X-ray diffraction. The combination of a multichannel collimator with diamond anvil cells enabled the measurement of structural changes in silica glass with total X-ray diffraction to previously unachievable pressures. We show that SiO2 first undergoes a change in Si–O coordination number from fourfold to sixfold between 15 and 50 GPa, in agreement with previous investigations. Above 50 GPa, the estimated coordination number continuously increases from 6 to 6.8 at 172 GPa. Si–O bond length shows first an increase due to the fourfold to sixfold coordination change and then a smaller linear decrease up to 172 GPa. We reconcile the changes in relation to the oxygen-packing fraction, showing that oxygen packing decreases at ultrahigh pressures to accommodate the higher than sixfold Si–O coordination. These results give experimental insight into the structural changes of silicate glasses as analogue materials for silicate melts at ultrahigh pressures. PMID:28874582
Beyond sixfold coordinated Si in SiO2 glass at ultrahigh pressures.
Prescher, Clemens; Prakapenka, Vitali B; Stefanski, Johannes; Jahn, Sandro; Skinner, Lawrie B; Wang, Yanbin
2017-09-19
We investigated the structure of SiO 2 glass up to 172 GPa using high-energy X-ray diffraction. The combination of a multichannel collimator with diamond anvil cells enabled the measurement of structural changes in silica glass with total X-ray diffraction to previously unachievable pressures. We show that SiO 2 first undergoes a change in Si-O coordination number from fourfold to sixfold between 15 and 50 GPa, in agreement with previous investigations. Above 50 GPa, the estimated coordination number continuously increases from 6 to 6.8 at 172 GPa. Si-O bond length shows first an increase due to the fourfold to sixfold coordination change and then a smaller linear decrease up to 172 GPa. We reconcile the changes in relation to the oxygen-packing fraction, showing that oxygen packing decreases at ultrahigh pressures to accommodate the higher than sixfold Si-O coordination. These results give experimental insight into the structural changes of silicate glasses as analogue materials for silicate melts at ultrahigh pressures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hungerford, D.S.; Lennox, D.W.
1985-10-01
Early diagnosis of osteonecrosis by radiograph, bone scan, CT scan, magnetic resonance imaging (MRI), intraosseous pressure measurement, or intraosseous venogram can lead to early successful treatment. For early (Ficat stages I and II) osteonecrosis of the hip, core decompression can provide diagnostic confirmation and pain relief and may prevent progression of disease. For more advanced disease (Ficat stages II and IV), osteotomy, endoprosthetic or bipolar prosthetic replacement, total hip arthroplasty, and arthrodesis are surgical options.86 references.
Lu, Xueling; Xu, Xijin; Zhang, Yu; Zhang, Yuling; Wang, Chenyang; Huo, Xia
2018-03-01
Cardiovascular toxicity of lead (Pb) manifests primarily as an effect on blood pressure and eventual increased risk of atherosclerosis and cardiovascular events. Therefore, we investigated vascular inflammatory biomarkers and cardiovascular effects of Pb-exposed children. A total of 590 children (3-7 years old) were recruited from Guiyu (n = 337), an electronic waste (e-waste)-exposed group, and Haojiang (n = 253), a reference group, from November to December 2016. We measured child blood Pb levels (BPbs), and systolic and diastolic blood pressure. Pulse pressure was calculated for the latter two. Serum biomarkers including lipid profiles and inflammatory cytokines, and plasma lipoprotein-associated phospholipase A2 (Lp-PLA2) were detected. Unadjusted regression analysis illustrated that higher ln-transformed BPb associated with lower systolic blood pressure and pulse pressure. After adjustment for various confounders, the relational degree of lnBPb and blood pressure measures became slightly attenuated or not significant. Elevated BPb was associated with higher Lp-PLA2, interleukin (IL)-6, triglycerides (TG) and lower high-density lipoprotein (HDL). Lp-PLA2 remained inversely associated with pulse pressure and HDL, but positively with ratios of total cholesterol to HDL (Tc/HDL) and low-density lipoprotein to HDL (LDL/HDL). IL-6 was associated negatively with systolic blood pressure, pulse pressure and HDL, and positively associated with TG, Tc/HDL and LDL/HDL. The mediation effect of biomarkers on the association of BPb with pulse pressure was insignificant except for Lp-PLA2. Available data supports the conclusion that e-waste-exposed children with higher BPbs and concomitant abnormal measures of cardiovascular physiology have an augmented prevalence of vascular inflammation, as well as lipid disorder. Copyright © 2017 Elsevier Ltd. All rights reserved.
Unsteady specific work and isentropic efficiency of a radial turbine driven by pulsed detonations
NASA Astrophysics Data System (ADS)
Rouser, Kurt P.
There has been longstanding government and industry interest in pressure-gain combustion for use in Brayton cycle based engines. Theoretically, pressure-gain combustion allows heat addition with reduced entropy loss. The pulsed detonation combustor (PDC) is a device that can provide such pressure-gain combustion and possibly replace typical steady deflagration combustors. The PDC is inherently unsteady, however, and comparisons with conventional steady deflagration combustors must be based upon time-integrated performance variables. In this study, the radial turbine of a Garrett automotive turbocharger was coupled directly to and driven, full admission, by a PDC in experiments fueled by hydrogen or ethylene. Data included pulsed cycle time histories of turbine inlet and exit temperature, pressure, velocity, mass flow, and enthalpy. The unsteady inlet flowfield showed momentary reverse flow, and thus unsteady accumulation and expulsion of mass and enthalpy within the device. The coupled turbine-driven compressor provided a time-resolved measure of turbine power. Peak power increased with PDC fill fraction, and duty cycle increased with PDC frequency. Cycle-averaged unsteady specific work increased with fill fraction and frequency. An unsteady turbine efficiency formulation is proposed, including heat transfer effects, enthalpy flux-weighted total pressure ratio, and ensemble averaging over multiple cycles. Turbine efficiency increased with frequency but was lower than the manufacturer reported conventional steady turbine efficiency.
Nikkhoo, Mohammad; Khalaf, Kinda; Kuo, Ya-Wen; Hsu, Yu-Chun; Haghpanahi, Mohammad; Parnianpour, Mohamad; Wang, Jaw-Lin
2015-01-01
The risk of low back pain resulted from cyclic loadings is greater than that resulted from prolonged static postures. Disk degeneration results in degradation of disk solid structures and decrease of water contents, which is caused by activation of matrix digestive enzymes. The mechanical responses resulted from internal solid-fluid interactions of degenerative disks to cyclic loadings are not well studied yet. The fluid-solid interactions in disks can be evaluated by mathematical models, especially the poroelastic finite element (FE) models. We developed a robust disk poroelastic FE model to analyze the effect of degeneration on solid-fluid interactions within disk subjected to cyclic loadings at different loading frequencies. A backward analysis combined with in vitro experiments was used to find the elastic modulus and hydraulic permeability of intact and enzyme-induced degenerated porcine disks. The results showed that the averaged peak-to-peak disk deformations during the in vitro cyclic tests were well fitted with limited FE simulations and a quadratic response surface regression for both disk groups. The results showed that higher loading frequency increased the intradiscal pressure, decreased the total fluid loss, and slightly increased the maximum axial stress within solid matrix. Enzyme-induced degeneration decreased the intradiscal pressure and total fluid loss, and barely changed the maximum axial stress within solid matrix. The increase of intradiscal pressure and total fluid loss with loading frequency was less sensitive after the frequency elevated to 0.1 Hz for the enzyme-induced degenerated disk. Based on this study, it is found that enzyme-induced degeneration decreases energy attenuation capability of disk, but less change the strength of disk.
Nikkhoo, Mohammad; Khalaf, Kinda; Kuo, Ya-Wen; Hsu, Yu-Chun; Haghpanahi, Mohammad; Parnianpour, Mohamad; Wang, Jaw-Lin
2015-01-01
The risk of low back pain resulted from cyclic loadings is greater than that resulted from prolonged static postures. Disk degeneration results in degradation of disk solid structures and decrease of water contents, which is caused by activation of matrix digestive enzymes. The mechanical responses resulted from internal solid–fluid interactions of degenerative disks to cyclic loadings are not well studied yet. The fluid–solid interactions in disks can be evaluated by mathematical models, especially the poroelastic finite element (FE) models. We developed a robust disk poroelastic FE model to analyze the effect of degeneration on solid–fluid interactions within disk subjected to cyclic loadings at different loading frequencies. A backward analysis combined with in vitro experiments was used to find the elastic modulus and hydraulic permeability of intact and enzyme-induced degenerated porcine disks. The results showed that the averaged peak-to-peak disk deformations during the in vitro cyclic tests were well fitted with limited FE simulations and a quadratic response surface regression for both disk groups. The results showed that higher loading frequency increased the intradiscal pressure, decreased the total fluid loss, and slightly increased the maximum axial stress within solid matrix. Enzyme-induced degeneration decreased the intradiscal pressure and total fluid loss, and barely changed the maximum axial stress within solid matrix. The increase of intradiscal pressure and total fluid loss with loading frequency was less sensitive after the frequency elevated to 0.1 Hz for the enzyme-induced degenerated disk. Based on this study, it is found that enzyme-induced degeneration decreases energy attenuation capability of disk, but less change the strength of disk. PMID:25674562
He, Yong-Han; Pu, Shao-Yan; Xiao, Fu-Hui; Chen, Xiao-Qiong; Yan, Dong-Jing; Liu, Yao-Wen; Lin, Rong; Liao, Xiao-Ping; Yu, Qin; Yang, Li-Qin; Yang, Xing-Li; Ge, Ming-Xia; Li, Ying; Jiang, Jian-Jun; Cai, Wang-Wei; Kong, Qing-Peng
2016-02-25
Centenarians are a good healthy aging model. Interestingly, centenarians' offspring are prone to achieve longevity. Here we recruited 60 longevity families and investigated the blood biochemical indexes of family members to seek candidate factors associated with familial longevity. First, associations of blood indexes with age were tested. Second, associations of blood parameters in centenarians (CEN) with their first generation of offspring (F1) and F1 spouses (F1SP) were analyzed. Third, genes involved in regulating target factors were investigated. We found that total cholesterol (TC) and triglyceride (TG) increased with age (20-80 years), but decreased in CEN. Similarly, blood urea nitrogen (BUN) and blood creatinine (BCr) increased with age (20-80 years), but were maintained on a plateau in CEN. Importantly, we first revealed dual changes in blood pressure, i.e., decreased diastolic blood pressure but increased systolic blood pressure in CEN, which associated with altered CST3 expression. Genetic analysis revealed a significant association of blood uric acid (BUA) and BCr in CEN with F1 but not with F1SP, suggesting they may be heritable traits. Taken together, our results suggest serum lipids, kidney function and especially diastolic pressure rather than systolic pressure were improved in CEN or their offspring, suggesting these factors may play an important role in familial longevity.
Inada, Kim Op; Torres, Alexandre G; Perrone, Daniel; Monteiro, Mariana
2018-01-01
Jabuticaba (Myrciaria jaboticaba) is a Brazilian fruit rich in phenolic compounds and much appreciated for its sweet and slightly tangy taste. However, the high perishability of this fruit impairs its economic exploitation, creating an opportunity for the development of innovative products, such as high hydrostatic pressure (HHP) processed juices. We investigated the effect of HHP (200, 350 and 500 MPa for 5, 7.5 and 10 min) on phenolic compounds, antioxidant activity and microbiological quality of jabuticaba juice and the effect of the most effective HHP condition on its sensory acceptance. Pressurization increased total phenolic compound content (up to 38%) and antioxidant activity by FRAP assay (up to 46%), probably by increasing phenolic compound extractability due to tissue damage. Pressurization progressively decreased microbial counts, and colony growth was undetectable at pressures of 350 MPa or 500 MPa. With the exception of aroma, which was 10% lower in pressurized juice at 350 MPa for 7.5 min in relation to unprocessed juice, HHP did not affect sensory acceptance scores. Our results show that HHP was effective in ensuring microbiological quality, increasing bioactive potential and maintaining overall acceptance of jabuticaba juice, reinforcing the potential application of this processing technology in bioactive-rich foods. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
Schuitemaker, G E; Dinant, G J; van der Pol, G A; Appels, A
2004-01-01
Vital exhaustion, a state characterized by unusual fatigue, loss of energy, increased irritability, and feelings of demoralization, is one of the cardiovascular risk factors. The authors investigated whether vital exhaustion contributes to the identification of subjects at increased risk of myocardial infarction in general practice. In this prospective cohort study, vital exhaustion was assessed with the Maastricht Interview on Vital Exhaustion. Other cardiovascular risk factors established were age, gender, systolic and diastolic blood pressure, total cholesterol, body mass index, smoking habits, cardiovascular disease, and diabetes mellitus. A Cox regression analysis was used. The subjects were adults (41-66 years) in an average Dutch village population. Outcome measures were fatal and nonfatal myocardial infarction. At the univariate level, vital exhaustion doubled the risk of myocardial infarction. The effect of exhaustion was confounded by gender; women had higher exhaustion scores and a lower incidence of myocardial infarction. With control for gender, age, systolic blood pressure, total cholesterol, smoking habits, self-reported cardiovascular disease, and diabetes mellitus, vital exhaustion almost tripled the risk of myocardial infarction. Assessment of vital exhaustion contributes to the identification of subjects at increased risk of myocardial infarction in general practice.
Park, Shin Hye; Boyle, Diane K; Bergquist-Beringer, Sandra; Staggs, Vincent S; Dunton, Nancy E
2014-08-01
We examined the concurrent and lagged effects of registered nurse (RN) turnover on unit-acquired pressure ulcer rates and whether RN staffing mediated the effects. Quarterly unit-level data were obtained from the National Database of Nursing Quality Indicators for 2008 to 2010. A total of 10,935 unit-quarter observations (2,294 units, 465 hospitals) were analyzed. This longitudinal study used multilevel regressions and tested time-lagged effects of study variables on outcomes. The lagged effect of RN turnover on unit-acquired pressure ulcers was significant, while there was no concurrent effect. For every 10 percentage-point increase in RN turnover in a quarter, the odds of a patient having a pressure ulcer increased by 4 percent in the next quarter. Higher RN turnover in a quarter was associated with lower RN staffing in the current and subsequent quarters. Higher RN staffing was associated with lower pressure ulcer rates, but it did not mediate the relationship between turnover and pressure ulcers. We suggest that RN turnover is an important factor that affects pressure ulcer rates and RN staffing needed for high-quality patient care. Given the high RN turnover rates, hospital and nursing administrators should prepare for its negative effect on patient outcomes. © Health Research and Educational Trust.
Park, Shin Hye; Boyle, Diane K; Bergquist-Beringer, Sandra; Staggs, Vincent S; Dunton, Nancy E
2014-01-01
Objective We examined the concurrent and lagged effects of registered nurse (RN) turnover on unit-acquired pressure ulcer rates and whether RN staffing mediated the effects. Data Sources/Setting Quarterly unit-level data were obtained from the National Database of Nursing Quality Indicators for 2008 to 2010. A total of 10,935 unit-quarter observations (2,294 units, 465 hospitals) were analyzed. Methods This longitudinal study used multilevel regressions and tested time-lagged effects of study variables on outcomes. Findings The lagged effect of RN turnover on unit-acquired pressure ulcers was significant, while there was no concurrent effect. For every 10 percentage-point increase in RN turnover in a quarter, the odds of a patient having a pressure ulcer increased by 4 percent in the next quarter. Higher RN turnover in a quarter was associated with lower RN staffing in the current and subsequent quarters. Higher RN staffing was associated with lower pressure ulcer rates, but it did not mediate the relationship between turnover and pressure ulcers. Conclusions We suggest that RN turnover is an important factor that affects pressure ulcer rates and RN staffing needed for high-quality patient care. Given the high RN turnover rates, hospital and nursing administrators should prepare for its negative effect on patient outcomes. PMID:24476194
Effects of Sinoaortic Denervation on Hemodynamic Parameters During Natural Sleep in Rats
Silveira, Neide P.; Moreira, Edson D.; Drager, Luciano F.; Silva, Gustavo J. J.; Krieger, Eduardo M.
2008-01-01
Study Objectives: To analyze the role of arterial baroreflex on hemodynamic changes during synchronized and desynchronized sleep phases of natural sleep in rats. Design: Experimental study. Setting: Laboratory. Participants: Seventeen male Wistar rats. Interventions: No intervention (control, n = 8) or sinoaortic denervation (SAD, n = 9). Measurements and Results: Sleep phases were monitored by electrocorticogram, and blood pressure was measured directly by a catheter in the carotid artery. Cardiac output, as well as total and regional vascular resistances, were determined by measuring the subdiaphragmatic aorta and iliac artery flows with Doppler flow probes, respectively. In contrast to the control group, the SAD group had a strong reduction in blood pressure (−19.9% ± 2.6% vs −0.7% ± 2.1%) during desynchronized sleep, and cardiac output showed an exacerbated reduction (−10.4% ± 3.5% vs 1.1% ± 1.7%). In SAD rats, total vascular resistance decreased during desynchronized sleep (−10.1% ± 3.5% vs −1.0% ± 1.7%), and the increase in regional vascular resistance observed in the control group was abolished (27.5% ± 8.3% vs −0.8% ± 9.4%). Conclusions: SAD caused profound changes in blood pressure, cardiac output, and total vascular resistance, with a significant increase in muscle vascular resistance during synchronized sleep. Our results suggest that baroreflex plays an important role in maintaining the normal balance of cardiac output and total vascular resistance during sleep. Citation: Silveira NP; Moreira ED; Drager LF; Silva GJJ; Krieger EM. Effects of sinoaortic denervation on hemodynamic parameters during natural sleep in rats. SLEEP 2008;31(3):328-333. PMID:18363308
RP-1 Thermal Stability and Copper Based Materials Compatibility Study
NASA Technical Reports Server (NTRS)
Stiegemeier, B. R.; Meyer, M. L.; Driscoll, E.
2005-01-01
A series of electrically heated tube tests was performed at the NASA Glenn Research Center s Heated Tube Facility to investigate the effect that sulfur content, test duration, and tube material play in the overall thermal stability and materials compatibility characteristics of RP-1. Scanning-electron microscopic (SEM) analysis in conjunction with energy dispersive spectroscopy (EDS) were used to characterize the condition of the tube inner wall surface and any carbon deposition or corrosion formed during these runs. Results of the parametric study indicate that tests with standard RP-1 (total sulfur -23 ppm) and pure copper tubing are characterized by a depostion/deposit shedding process producing local wall temperature swings as high as 500 F. The effect of this shedding is to keep total carbon deposition levels relatively constant for run times from 20 minutes up to 5 hours, though increasing tube pressure drops were observed in all runs. Reduction in the total sulfur content of the fuel from 23 ppm to less than 0.1 ppm resulted in the elimination of deposit shedding, local wall temperature variation, and the tube pressure drop increases that were observed in standard sulfur level RP-1 tests. The copper alloy GRCop-84, a copper alloy developed specifically for high heat flux applications, was found to exhibit higher carbon deposition levels compared to identical tests performed in pure copper tubes. Results of the study are consistent with previously published heated tube data which indicates that small changes in fuel total sulfur content can lead to significant differences in the thermal stability of kerosene type fuels and their compatibility with copper based materials. In conjunction with the existing thermal stability database, these findings give insight into the feasibility of cooling a long life, high performance, high-pressure liquid rocket combustor and nozzle with RP-1.
Nakamura, Maria Aparecida Miyuki; Costa, Eduardo Leite Vieira; Carvalho, Carlos Roberto Ribeiro; Tucci, Mauro Roberto
2014-01-01
Discomfort and noncompliance with noninvasive ventilation (NIV) interfaces are obstacles to NIV success. Total face masks (TFMs) are considered to be a very comfortable NIV interface. However, due to their large internal volume and consequent increased CO2 rebreathing, their orifices allow proximal leaks to enhance CO2 elimination. The ventilators used in the ICU might not adequately compensate for such leakage. In this study, we attempted to determine whether ICU ventilators in NIV mode are suitable for use with a leaky TFM. This was a bench study carried out in a university research laboratory. Eight ICU ventilators equipped with NIV mode and one NIV ventilator were connected to a TFM with major leaks. All were tested at two positive end-expiratory pressure (PEEP) levels and three pressure support levels. The variables analyzed were ventilation trigger, cycling off, total leak, and pressurization. Of the eight ICU ventilators tested, four did not work (autotriggering or inappropriate turning off due to misdetection of disconnection); three worked with some problems (low PEEP or high cycling delay); and one worked properly. The majority of the ICU ventilators tested were not suitable for NIV with a leaky TFM.
Yung-Hui, Lee; Wei-Hsien, Hong
2005-05-01
Studying the impact of high-heeled shoes on kinetic changes and perceived discomfort provides a basis to advance the design and minimize the adverse effects on the human musculoskeletal system. Previous studies demonstrated the effects of inserts on kinetics and perceived comfort in flat or running shoes. No study attempted to investigate the effectiveness of inserts in high heel shoes. The purpose of this study was to determine whether increasing heel height and the use of shoe inserts change foot pressure distribution, impact force, and perceived comfort during walking. Ten healthy females volunteered for the study. The heel heights were 1.0cm (flat), 5.1cm (low), and 7.6cm (high). The heel height effects were examined across five shoe-insert conditions of shoe only; heel cup, arch support, metatarsal pad, and total contact insert (TCI). The results indicated that increasing heel height increases impact force (p<0.01), medial forefoot pressure (p<0.01), and perceived discomfort (p<0.01) during walking. A heel cup insert for high-heeled shoes effectively reduced the heel pressure and impact force (p<0.01), an arch support insert reduced the medial forefoot pressure, and both improved footwear comfort (p<0.01). In particular, a TCI reduced heel pressure by 25% and medial forefoot pressure by 24%, attenuate the impact force by 33.2%, and offered higher perceived comfort when compared to the non-insert condition.
Wang, Lijuan; Feng, Liangshu; Yao, Yan; Wang, Yuzhi; Chen, Ying; Feng, Jiachun; Xing, Yingqi
2015-01-01
Ultrasonography of the optic nerve sheath diameter (ONSD) is a non-invasive and rapid method that might be helpful in the identification of increased intracranial pressure (ICP). The use of an ONSD greater than 5 mm on ultrasound as an indicator of increased ICP in a Caucasian population has been studied. However, the cut-off point of this predictor in Chinese patients has not been established. Thus, we conducted this study to identify the ONSD criterion for the detection of elevated opening pressure on lumbar puncture (LP) in a Chinese population and to investigate the influencing factors. This study was a blind cross-sectional study. Patients who presented with suspected increased ICP were included. The opening pressure on LP of each participant was confirmed. We analyzed the clinical differences between the groups of patients with abnormal and normal opening pressures on LP. A receiver operating characteristic curve was constructed to determine the ONSD cut-off point for the identification of abnormal opening pressure on LP. In total, 279 patients were recruited, and 101 patients presented with elevated opening pressure on LP. ONSD was a significant independent predictor of elevated opening pressure on LP (p<0.001). However, no statistical significance was observed regarding the factors that might have affected this relationship including gender, age, body mass index, waistline, head circumference, hypertension and pathological subtype. The ONSD cut-off point for the identification of elevated opening pressure on LP was 4.1 mm; this cut-off yielded a sensitivity of 95% and a specificity of 92%. ONSD is a strong and accurate predictor of elevated opening pressure on LP. The cut-off point of this predictor in a Chinese population was remarkably lower than that found in a Caucasian population. Thus, ethnic differences should be noted when using the ONSD as an indicator of increased ICP.
Gasdynamic Inlet Isolation in Rotating Detonation Engine
2010-12-01
2D Total Variation Diminishing (TVD): Continuous Riemann Solver Minimum Dissipation: LHS & RHS Activate pressure switch : Supersonic Activate...Total Variation Diminishing (TVD) limiter: Continuous Riemann Solver Minimum Dissipation: LHS & RHS Activate pressure switch : Supersonic Activate...Continuous 94 Riemann Solver Minimum Dissipation: LHS & RHS Activate pressure switch : Supersonic Activate pressure gradient switch: Normal
Maas, Jacinta J.; de Wilde, Rob B.; Aarts, Leon P.; Pinsky, Michael R.; Jansen, Jos R.
2012-01-01
Background Mean systemic filling pressure (Pmsf) can be determined at the bedside by measuring central venous pressure (Pcv) and cardiac output (CO) during inspiratory hold maneuvers. Critical closing pressure (Pcc) can be determined using the same method measuring arterial pressure (Pa) and CO. If Pcc > Pmsf there is then a vascular waterfall. In this study we assessed the existence of a waterfall and its implications for the calculation of vascular resistances by determining Pmsf and Pcc at the bedside. Methods In 10 mechanically ventilated postcardiac surgery patients inspiratory hold maneuvers were performed, transiently increasing Pcv and decreasing Pa and CO to four different steady-state levels. For each patient values of Pcv and CO were plotted in a venous return curve to determine Pmsf. Similarly, Pcc was determined with a ventricular output curve plotted for Pa and CO. Measurements were performed in each patient before and after volume expansion with 0.5 l colloid and vascular resistances were calculated. Results For every patient the relationship between the four measurements of Pcv and CO and of Pa and CO was linear. Baseline Pmsf was 18.7±4.0 (mean±SD) mmHg and differed significantly from Pcc 45.5±11.1 mmHg; (p<0.0001). The difference of Pcc and Pmsf was 26.8±10.7 mmHg, indicating the presence of a systemic vascular waterfall. Volume expansion increased Pmsf (26.3±3.2 mmHg), Pcc (51.5±9.0 mmHg) and CO (5.5±1.8 to 6.8±1.8 l·min−1). Arterial (upstream of Pcc) and venous (down-stream of Pmsf) vascular resistance were 8.27±4.45 and 2.75±1.23 mmHg·min·l−1; the sum of both (11.01 mmHg·min·l−1) was significantly different from total systemic vascular resistance (16.56±8.57 mmHg·min·l−1, p=0.005). Arterial resistance was related to total resistance. Conclusions Vascular pressure gradients in cardiac surgery patients suggest the presence of a vascular waterfall phenomenon, which is not affected by CO. Thus measures of total systemic vascular resistance may become irrelevant in assessing systemic vasomotor tone. PMID:22344243
Exercise-induced Pulmonary Hypertension
Vanderpool, Rebecca; Dhakal, Bishnu P.; Saggar, Rajeev; Saggar, Rajan; Vachiery, Jean-Luc; Lewis, Gregory D.
2013-01-01
Exercise stresses the pulmonary circulation through increases in cardiac output (Q.) and left atrial pressure. Invasive as well as noninvasive studies in healthy volunteers show that the slope of mean pulmonary artery pressure (mPAP)–flow relationships ranges from 0.5 to 3 mm Hg⋅min⋅L−1. The upper limit of normal mPAP at exercise thus approximates 30 mm Hg at a Q. of less than 10 L⋅min−1 or a total pulmonary vascular resistance at exercise of less than 3 Wood units. Left atrial pressure increases at exercise with an average upstream transmission to PAP in a close to one-for-one mm Hg fashion. Multipoint PAP–flow relationships are usually described by a linear approximation, but present with a slight curvilinearity, which is explained by resistive vessel distensibility. When mPAP is expressed as a function of oxygen uptake or workload, plateau patterns may be observed in patients with systolic heart failure who cannot further increase Q. at the highest levels of exercise. Exercise has to be dynamic to avoid the increase in systemic vascular resistance and abrupt changes in intrathoracic pressure that occur with resistive exercise and can lead to unpredictable effects on the pulmonary circulation. Postexercise measurements are unreliable because of the rapid return of pulmonary vascular pressures and flows to the baseline resting state. Recent studies suggest that exercise-induced increase in PAP to a mean higher than 30 mm Hg may be associated with dyspnea-fatigue symptomatology. PMID:23348976
Akese, M I; Adejumo, P O; Ilesanmi, R E; Obilor, H N
2014-09-01
The increase in the prevalence of pressure ulcer among patients with impaired physical mobility has currently been associated with nurses' inadequate knowledge of preventive interventions. To assess nurses' knowledge of pressure ulcer identification/staging, risk factors and evidence-based preventive practices. This descriptive study was carried out at the University Teaching Hospital Maiduguri (UMTH), Borno State, Nigeria. Total sampling technique was utilized in the recruitment of the study participants. An adapted 75-item-pressure ulcer questionnaire was used for data collection. The data were analyzed using SPSS version 16. The hypotheses on nurses' knowledge were tested at 0.05 level of significance using Chi square test. A total of 219 nurses participated in this study with response rate of 68.0%. The nurses' years of professional practice ranged from 1 to 35 years with a mean of 11.7 (± 7.8) years. Approximately, 73% of the nurses demonstrated a low level of knowledge of pressure ulcer identification/staging, 69.4% demonstrated an average level of knowledge of risk factors and 79.9% demonstrated high level of knowledge of preventive practices. The relationship between nurses' knowledge of risk factors and knowledge of preventive practices (p = 0.37) was not significant. Nurses demonstrated a knowledge deficit in core areas on pressure ulcer identification/staging, risk factors' assessment and evidence-based preventive practices. In order to address this dearth, there is a need to institute an educational-based practice-guideline on pressure ulcer prevention for nurses.
NASA Technical Reports Server (NTRS)
Kamhawi, Hani; Huang, Wensheng; Haag, Thomas; Yim, John; Herman, Daniel; Peterson, Peter Y.; Williams, George J.; Gilland, James; Hofer, Richard; Mikellides, Ioannis
2016-01-01
NASA's Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5 kW Technology Demonstration Unit-1 (TDU-1) has been the subject of extensive technology maturation in preparation for flight system development. Part of the technology maturation effort included experimental evaluation of the TDU-1 thruster with conducting and dielectric front pole cover materials in two different electrical configurations. A graphite front magnetic pole cover thruster configuration with the thruster body electrically tied to cathode, and an alumina front pole cover thruster configuration with the thruster body floating were evaluated. Both configurations were also evaluated at different facility background pressure conditions to evaluate background pressure effects on thruster operation. Performance characterization tests found that higher thruster performance was attained with the graphite front pole cover configuration with the thruster electrically tied to cathode. A total thrust efficiency of 68% and a total specific impulse of 2,820 s was demonstrated at a discharge voltage of 600 V and a discharge power of 12.5 kW. Thruster stability regimes were characterized with respect to the thruster discharge current oscillations and with maps of the discharge current-voltage-magnetic field (IVB). Analysis of TDU-1 discharge current waveforms found that lower normalized discharge current peak-to-peak and root mean square magnitudes were attained when the thruster was electrically floated with alumina front pole covers. Background pressure effects characterization tests indicated that the thruster performance and stability were mostly invariant to changes in the facility background pressure for vacuum chamber pressure below 1×10-5 Torr-Xe (for thruster flow rates of 20.5 mg/s). Power spectral density analysis of the discharge current waveforms showed that increasing the vacuum chamber background pressure resulted in a higher discharge current dominant breathing mode frequency. Finally, IVB maps of the TDU-1 thruster indicated that the discharge current became more oscillatory with higher discharge current peak-to-peak and RMS values with increased facility background pressure at lower thruster mass flow rates; thruster operation at higher flow rates resulted in less change to the thruster's IVB characteristics with elevated background pressure.
Energy efficient engine: Turbine transition duct model technology report
NASA Technical Reports Server (NTRS)
Leach, K.; Thurlin, R.
1982-01-01
The Low-Pressure Turbine Transition Duct Model Technology Program was directed toward substantiating the aerodynamic definition of a turbine transition duct for the Energy Efficient Engine. This effort was successful in demonstrating an aerodynamically viable compact duct geometry and the performance benefits associated with a low camber low-pressure turbine inlet guide vane. The transition duct design for the flight propulsion system was tested and the pressure loss goal of 0.7 percent was verified. Also, strut fairing pressure distributions, as well as wall pressure coefficients, were in close agreement with analytical predictions. Duct modifications for the integrated core/low spool were also evaluated. The total pressure loss was 1.59 percent. Although the increase in exit area in this design produced higher wall loadings, reflecting a more aggressive aerodynamic design, pressure profiles showed no evidence of flow separation. Overall, the results acquired have provided pertinent design and diagnostic information for the design of a turbine transition duct for both the flight propulsion system and the integrated core/low spool.
Devatkal, Suresh; Anurag, Rahul; Jaganath, Bindu; Rao, Srinivasa
2015-10-01
High-pressure processing (300 MPa for 5 min) as a non-thermal post-processing intervention was employed to improve the shelf life and qualities of cooked refrigerated chicken nuggets. Pomegranate peel extract (1%) was also used as a source of natural antioxidant and antimicrobial in chicken nuggets. Microstructure, microbial profile, instrumental colour, texture profile and lipid oxidation were evaluated. High-pressure treatment and pomegranate peel extract did not influence significantly the colour and textural properties of cooked chicken nuggets. Thiobarbituric acid reactive substance values significantly (p < 0.05) increased in pressure-treated nuggets. Microstructural studies revealed shrinkage in the structure and loosening of the dense network of meat emulsion due to high-pressure treatment. Pressure treatment resulted in a reduction of 2-3.0 log10 cfu/g in total plate count and Enterobacteriaceae count. Molecular characterization studies revealed that Enterobacter amnigenus and Enterobacter sp. in control and Bacillus licheniformis, Enterococcus gallinarum and Acinetobacter baumannii in high-pressure-treated chicken nuggets were the major spoilage bacteria. © The Author(s) 2014.
Yang, Zhikuan; Ge, Jian; Yin, Wei; Shen, Huangxuan; Liu, Haiquan; Guo, Yan
2004-12-01
To investigate the expression of p53, MDM2 and Ref1 gene in cultured retina neurons of SD rats treated with Vitamin B1 and (or) elevated pressure. The retinal neuron of postnatal SD rats were cultured in vivo, the elevated pressure was produced after 7 days, and the total RNA was extracted after another 2 days, expression of p53, MDM2 and Ref1 gene were analyzed with RT-PCR. The expression level of p53 and MDM2 gene were increased in elevated pressure group, normal with Ref1 gene expression. But the expression of p53 and MDM2 gene were decreased significantly in elevated pressure group treated with vitamine B1 compare to the elevated group. Apoptosis seem to be a mechanism of cell death in retinal neurons of SD rats with elevated pressure.Vitamine B1 have protect effects against elevated pressure.
Numerical prediction of micro-channel LD heat sink operated with antifreeze based on CFD method
NASA Astrophysics Data System (ADS)
Liu, Gang; Liu, Yang; Wang, Chao; Wang, Wentao; Wang, Gang; Tang, Xiaojun
2014-12-01
To theoretically study the feasibility of antifreeze coolants applied as cooling fluids for high power LD heat sink, detailed Computational Fluid Dynamics (CFD) analysis of liquid cooled micro-channels heat sinks is presented. The performance operated with antifreeze coolant (ethylene glycol aqueous solution) compared with pure water are numerical calculated for the heat sinks with the same micro-channels structures. The maximum thermal resistance, total pressure loss (flow resistance), thermal resistance vs. flow-rate, and pressure loss vs. flow-rate etc. characteristics are numerical calculated. The results indicate that the type and temperature of coolants plays an important role on the performance of heat sinks. The whole thermal resistance and pressure loss of heat sinks increase significantly with antifreeze coolants compared with pure water mainly due to its relatively lower thermal conductivity and higher fluid viscosity. The thermal resistance and pressure loss are functions of the flow rate and operation temperature. Increasing of the coolant flow rate can reduce the thermal resistance of heat sinks; meanwhile increase the pressure loss significantly. The thermal resistance tends to a limit with increasing flow rate, while the pressure loss tends to increase exponentially with increasing flow rate. Low operation temperature chiefly increases the pressure loss rather than thermal resistance due to the remarkable increasing of fluid viscosity. The actual working point of the cooling circulation system can be determined on the basis of the pressure drop vs. flow rate curve for the micro-channel heat sink and that for the circulation system. In the same system, if the type or/and temperature of the coolant is changed, the working point is accordingly influenced, that is, working flow rate and pressure is changed simultaneously, due to which the heat sink performance is influenced. According to the numerical simulation results, if ethylene glycol aqueous solution is applied instead of pure water as the coolant under the same or a higher working temperature, the available output of optical power will decrease due to the worse heat sink performance; if applied under a lower working temperature(0 °C, -20 °C), although the heat sink performance become worse, however the temperature difference of heat transfer rises more significantly, the available output of optical power will increase on the contrary.
Rezaei, Safoura Sheikh; Litschauer, Brigitte; Gouya, Gazaleh; Baumgartner-Parzer, Sabina; Stulnig, Thomas; Wolzt, Michael
2018-06-01
Increased free fatty acids stimulate sympathetic nervous system activity, impair endothelium-dependent vasodilation, and increase regional blood flow. The aim of this study was to assess if fatty acids acutely elevated by infusion of intralipid/heparin affect cardiovascular reactivity employing two stressors eliciting either a cardiac (Stroop test) or vascular (Cold Face test) dominated pressor response. Two stress tasks were performed in 20 healthy subjects (10 women, 10 men) before and during a 180-min intralipid/heparin or saline infusion as placebo on alternate trial days in a randomized crossover study design. Blood pressure, heart rate, cardiac index, and total peripheral resistance index were measured. At baseline, the Stroop test did not affect hemodynamic parameters, and the Cold Face test had an impact on hemodynamic parameters except for heart rate. Plasma fatty acids concentrations increased to 810% (t=11.0, p<0.001) of baseline and C-peptide increased by 17% (t=4.66, p<0.001) during intralipid/heparin infusion. This was paralleled by increased cardiac index (F=9.98; p<0.005 vs. saline) and reduced total peripheral resistance index (F=4.46; p<0.05 vs saline). There was no effect of intralipid/heparin or saline infusion on Stroop test or Cold Face test reactivity of hemodynamic parameters. An acute increase in free fatty acids does not affect the magnitude or pattern of stress response in healthy volunteers, but primarily alter the underlying cardiovascular tone by decreasing total peripheral resistance index and increasing cardiac index to maintain a constant blood pressure. © Georg Thieme Verlag KG Stuttgart · New York.
Foam imbibition in a Hele-Shaw cell via laminated microfluidic ``T-junction'' device
NASA Astrophysics Data System (ADS)
Parra, Dina; Ward, Thomas
2013-11-01
In this talk we analyze experimental results of a novel microfluidic ``T-junction'' device, made from laminated plastic, that is used to produce foam in porous media. The fluids, both Newtonian and non-Newtonian liquids and air, are driven using constant-static pressure fluid pumping. For the T-junction geometry studied there are novel observations with this type of pumping: 1) at low pressure ratios there is an increase in the liquid and total flow rates and 2) at higher pressure ratios there is a decrease in the liquid flow rate. To understand this phenomenon we visualize the drop production process near the T-junction. Furthermore, flow rates for the liquid and total volume are estimated by imbibing the foam into a Hele-Shaw cell. Foam is produced by using a mixture containing aqueous polyacrylamide of concentrations ranging from 0.01-0.10% by weight and several solution also containing a sodium-lauryl-sulfate (SLS) surfactant at concentrations ranging 0.01-0.1% by weight.
Simulation Of The Synovial Fluid In A Deformable Cavity
NASA Astrophysics Data System (ADS)
Martinez-Gutierrez, Nancy; Ibarra-Bracamontes, Laura A.
2016-11-01
The main components of a synovial joint are a cartilage and a biofluid known as the synovial fluid. The results were obtained using the FLUENT software to simulate the behavior of the synovial fluid within a deformable cavity with a simple geometry. The cartilage is represented as a porous region. By reducing the available region for the fluid, a fluid displacement into the cartilage is induced. The total pressure reached in the interface of the deformable cavity and the porous region is presented. The geometry and properties of the system are scaled to values found in a knee joint. The effect of deformation rate, fluid viscosity and properties of the porous medium on the total pressure reached are analyzed. The higher pressures are reached either for high deformation rate or when the fluid viscosity increases. This study was supported by the Mexican Council of Science and Technology (CONACyT) and by the Scientific Research Coordination of the University of Michoacan in Mexico.
Proteomics analysis in frozen horse mackerel previously high-pressure processed.
Pazos, Manuel; Méndez, Lucía; Vázquez, Manuel; Aubourg, Santiago P
2015-10-15
The effect of high-pressure processing (HPP) (150, 300 and 450 MPa for 0, 2.5 and 5 min) on total sodium dodecyl sulphate (SDS)-soluble and sarcoplasmic proteins in frozen (-10 °C for 3 months) horse mackerel (Trachurus trachurus) was evaluated. Proteomics tools based on image analysis of SDS-PAGE protein gels and protein identification by tandem mass spectrometry (MS/MS) were applied. Although total SDS-soluble fraction indicated no important changes induced by HPP, this processing modified the 1-D SDS-PAGE sarcoplasmic patterns in a direct-dependent manner and exerted a selective effect on particular proteins depending on processing conditions. Thus, application of the highest pressure (450 MPa) provoked a significant degradation of phosphoglycerate mutase 2, glycogen phosphorylase muscle form, pyruvate kinase muscle isozyme, beta-enolase and triosephosphate isomerase and phosphoglucomutase-1. Conversely, protein bands assigned to tropomyosin alpha-1 chain, fast myotomal muscle troponin T and parvalbumin beta 2 increased their intensity after applying a 450-MPa processing. Copyright © 2015 Elsevier Ltd. All rights reserved.
Induced groundwater flux by increases in the aquifer's total stress.
Chang, Ching-Min; Yeh, Hund-Der
2015-01-01
Fluid-filled granular soils experience changes in total stress because of earth and oceanic tides, earthquakes, erosion, sedimentation, and changes in atmospheric pressure. The pore volume may deform in response to the changes in stress and this may lead to changes in pore fluid pressure. The transient fluid flow can therefore be induced by the gradient in excess pressure in a fluid-saturated porous medium. This work demonstrates the use of stochastic methodology in prediction of induced one-dimensional field-scale groundwater flow through a heterogeneous aquifer. A closed-form of mean groundwater flux is developed to quantify the induced field-scale mean behavior of groundwater flow and analyze the impacts of the spatial correlation length scale of log hydraulic conductivity and the pore compressibility. The findings provided here could be useful for the rational planning and management of groundwater resources in aquifers that contain lenses with large vertical aquifer matrix compressibility values. © 2014, National Ground Water Association.
Error in Dasibi flight measurements of atmospheric ozone due to instrument wall-loss
NASA Technical Reports Server (NTRS)
Ainsworth, J. E.; Hagemeyer, J. R.; Reed, E. I.
1981-01-01
Theory suggests that in laminar flow the percent loss of a trace constituent to the walls of a measuring instrument varies as P to the -2/3, where P is the total gas pressure. Preliminary laboratory ozone wall-loss measurements confirm this P to the -2/3 dependence. Accurate assessment of wall-loss is thus of particular importance for those balloon-borne instruments utilizing laminar flow at ambient pressure, since the ambient pressure decreases by a factor of 350 during ascent to 40 km. Measurements and extrapolations made for a Dasibi ozone monitor modified for balloon flight indicate that the wall-loss error at 40 km was between 6 and 30 percent and that the wall-loss error in the derived total ozone column-content for the region from the surface to 40 km altitude was between 2 and 10 percent. At 1000 mb, turbulence caused an order of magnitude increase in the Dasibi wall-loss.
Increases in intramuscular pressure raise arterial blood pressure during dynamic exercise
NASA Technical Reports Server (NTRS)
Gallagher, K. M.; Fadel, P. J.; Smith, S. A.; Norton, K. H.; Querry, R. G.; Olivencia-Yurvati, A.; Raven, P. B.
2001-01-01
This investigation was designed to determine the role of intramuscular pressure-sensitive mechanoreceptors and chemically sensitive metaboreceptors in affecting the blood pressure response to dynamic exercise in humans. Sixteen subjects performed incremental (20 W/min) cycle exercise to fatigue under four conditions: control, exercise with thigh cuff occlusion of 90 Torr (Cuff occlusion), exercise with lower body positive pressure (LBPP) of 45 Torr, and a combination of thigh cuff occlusion and LBPP (combination). Indexes of central command (heart rate, oxygen uptake, ratings of perceived exertion, and electromyographic activity), cardiac output, stroke volume, and total peripheral resistance were not significantly different between the four conditions. Mechanical stimulation during LBPP and combination conditions resulted in significant elevations in intramuscular pressure and mean arterial pressure from control at rest and throughout the incremental exercise protocol (P < 0.05). Conversely, there existed no significant changes in mean arterial pressure when the metaboreflex was stimulated by cuff occlusion. These findings suggest that under normal conditions the mechanoreflex is tonically active and is the primary mediator of exercise pressor reflex-induced alterations in arterial blood pressure during submaximal dynamic exercise in humans.
Almeida, Francisca Diva Lima; Gomes, Wesley Faria; Cavalcante, Rosane Souza; Tiwari, Brijesh K; Cullen, Patrick J; Frias, Jesus Maria; Bourke, Paula; Fernandes, Fabiano A N; Rodrigues, Sueli
2017-12-01
In this study, the effect of atmospheric pressure cold plasma and high-pressure processing on the prebiotic orange juice was evaluated. Orange juice containing 7g/100g of commercial fructooligosaccharides (FOS) was directly and indirectly exposed to a plasma discharge at 70kV with processing times of 15, 30, 45 and 60s. For high-pressure processing, the juice containing the same concentration of FOS was treated at 450MPa for 5min at 11.5°C in an industrial equipment (Hyperbaric, model: 300). After the treatments, the fructooligosaccharides were qualified and quantified by thin layer chromatography. The organic acids and color analysis were also evaluated. The maximal overall fructooligosaccharides degradation was found after high-pressure processing. The total color difference was <3.0 for high-pressure and plasma processing. citric and ascorbic acid (Vitamin C) showed increased content after plasma and high-pressure treatment. Thus, atmospheric pressure cold plasma and high-pressure processing can be used as non-thermal alternatives to process prebiotic orange juice. Copyright © 2017 Elsevier Ltd. All rights reserved.
Weinberg, Ido; Gona, Philimon; O'Donnell, Christopher J; Jaff, Michael R; Murabito, Joanne M
2014-03-01
An increased interarm systolic blood pressure difference is an easily determined physical examination finding. The relationship between interarm systolic blood pressure difference and risk of future cardiovascular disease is uncertain. We described the prevalence and risk factor correlates of interarm systolic blood pressure difference in the Framingham Heart Study (FHS) original and offspring cohorts and examined the association between interarm systolic blood pressure difference and incident cardiovascular disease and all-cause mortality. An increased interarm systolic blood pressure difference was defined as ≥ 10 mm Hg using the average of initial and repeat blood pressure measurements obtained in both arms. Participants were followed through 2010 for incident cardiovascular disease events. Multivariable Cox proportional hazards regression analyses were performed to investigate the effect of interarm systolic blood pressure difference on incident cardiovascular disease. We examined 3390 (56.3% female) participants aged 40 years and older, free of cardiovascular disease at baseline, mean age of 61.1 years, who attended a FHS examination between 1991 and 1994 (original cohort) and from 1995 to 1998 (offspring cohort). The mean absolute interarm systolic blood pressure difference was 4.6 mm Hg (range 0-78). Increased interarm systolic blood pressure difference was present in 317 (9.4%) participants. The median follow-up time was 13.3 years, during which time 598 participants (17.6%) experienced a first cardiovascular event, including 83 (26.2%) participants with interarm systolic blood pressure difference ≥ 10 mm Hg. Compared with those with normal interarm systolic blood pressure difference, participants with an elevated interarm systolic blood pressure difference were older (63.0 years vs 60.9 years), had a greater prevalence of diabetes mellitus (13.3% vs 7.5%,), higher systolic blood pressure (136.3 mm Hg vs 129.3 mm Hg), and a higher total cholesterol level (212.1 mg/dL vs 206.5 mg/dL). Interarm systolic blood pressure difference was associated with a significantly increased hazard of incident cardiovascular events in the multivariable adjusted model (hazard ratio 1.38; 95% CI, 1.09-1.75). For each 1-SD-unit increase in absolute interarm systolic blood pressure difference, the hazard ratio for incident cardiovascular events was 1.07 (95% CI, 1.00-1.14) in the fully adjusted model. There was no such association with mortality (hazard ratio 1.02; 95% CI 0.76-1.38). In this community-based cohort, an interarm systolic blood pressure difference is common and associated with a significant increased risk for future cardiovascular events, even when the absolute difference in arm systolic blood pressure is modest. These findings support research to expand clinical use of this simple measurement. Copyright © 2014 Elsevier Inc. All rights reserved.
Kopeć, Jerzy; Januszek, Rafał; Wieczorek-Surdacka, Ewa; Sułowicz, Władysław
2009-01-01
During the last years the incidence of chronic kidney disease (CKD) is permanently increasing and has become a global social and economical problem in the world as well as in Poland. The aim of the study was the retrospective analysis of medical records of patients with renal failure under supervision at the outpatient clinic, Department of Nephrology, University Hospital in Cracow. The study population enclosed 1183 patients (640 men and 543 women) aged between 17 and 98 years (mean 64.7) with creatinine concentration >120 micromol/l and/or creatinine clearance <90 ml/min/1.73 m2. Hemoglobin, iron, creatinine, urea, sodium, potasium, calcium, phosphate, magnesium, PTH, uric acid, albumin, total protein, bilirubin, glucose, total cholesterol, LDL and HDL cholesterol, triglicerydes concentration and values of hematocrite, MCV, HbA1, as well as alkaline phosphatase, AspAT, AIAT activity were estimated based on standard laboratory methods. Creatinine clearances were evaluated based on 3 different methods: simplified MDRD formula, Cockcroft-Gault formula and 24-h urine collection. Mean creatinine concentration in the studied population was 172.8 micromol/l (1.95 mg/dl). Hypertension was diagnosed in 65% of patients. In spite of treatment, more than half of the patients (51.9%) have increased systolic blood pressure and above 1/3 (35%) increased diastolic blood pressure. Mean hemoglobin concentration was 13.02 g/dl; more than 12% of patients had decreased hemoglobin below 11 g/dl. Mean values of parameters discovering calcium-phosphate metabolism were: calcium--2.33 mmol/l, phosphate--1.23 mmol/l and parathormon--169.3 pg/ml. Increased value of total serum cholesterol level was noted more than half of the patients (56.5%). Significant positive correlations were found between GFR calculated based on Cockcroft-Gault formula and BMI, hemoglobin, hematocrite, serum iron, diastolic blood pressure, total and LDL serum cholesterol, triglicerydes level, as well as AIAT activity and % values of HbA1c and negative with age, serum potassium, phosphorus, PTH and uric acid.
Study of high viscous multiphase phase flow in a horizontal pipe
NASA Astrophysics Data System (ADS)
Baba, Yahaya D.; Aliyu, Aliyu M.; Archibong, Archibong-Eso; Almabrok, Almabrok A.; Igbafe, A. I.
2018-03-01
Heavy oil accounts for a major portion of the world's total oil reserves. Its production and transportation through pipelines is beset with great challenges due to its highly viscous nature. This paper studies the effects of high viscosity on heavy oil two-phase flow characteristics such as pressure gradient, liquid holdup, slug liquid holdup, slug frequency and slug liquid holdup using an advanced instrumentation (i.e. Electrical Capacitance Tomography). Experiments were conducted in a horizontal flow loop with a pipe internal diameter (ID) of 0.0762 m; larger than most reported in the open literature for heavy oil flow. Mineral oil of 1.0-5.0 Pa.s viscosity range and compressed air were used as the liquid and gas phases respectively. Pressure gradient (measured by means differential pressure transducers) and mean liquid holdup was observed to increase as viscosity of oil is increased. Obtained results also revealed that increase in liquid viscosity has significant effects on flow pattern and slug flow features.
A Soft Total Artificial Heart-First Concept Evaluation on a Hybrid Mock Circulation.
Cohrs, Nicholas H; Petrou, Anastasios; Loepfe, Michael; Yliruka, Maria; Schumacher, Christoph M; Kohll, A Xavier; Starck, Christoph T; Schmid Daners, Marianne; Meboldt, Mirko; Falk, Volkmar; Stark, Wendelin J
2017-10-01
The technology of 3D-printing has allowed the production of entirely soft pumps with complex chamber geometries. We used this technique to develop a completely soft pneumatically driven total artificial heart from silicone elastomers and evaluated its performance on a hybrid mock circulation. The goal of this study is to present an innovative concept of a soft total artificial heart (sTAH). Using the form of a human heart, we designed a sTAH, which consists of only two ventricles and produced it using a 3D-printing, lost-wax casting technique. The diastolic properties of the sTAH were defined and the performance of the sTAH was evaluated on a hybrid mock circulation under various physiological conditions. The sTAH achieved a blood flow of 2.2 L/min against a systemic vascular resistance of 1.11 mm Hg s/mL (afterload), when operated at 80 bpm. At the same time, the mean pulmonary venous pressure (preload) was fixed at 10 mm Hg. Furthermore, an aortic pulse pressure of 35 mm Hg was measured, with a mean aortic pressure of 48 mm Hg. The sTAH generated physiologically shaped signals of blood flow and pressures by mimicking the movement of a real heart. The preliminary results of this study show a promising potential of the soft pumps in heart replacements. Further work, focused on increasing blood flow and in turn aortic pressure is required. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Aspiyanto, Susilowati, Agustine; Iskandar, Jeti M.; Melanie, Hakiki; Maryati, Yati; Lotulung, Puspa D.
2017-01-01
Fermentation on spinach (Amaranthus sp.) vegetable by kombucha culture as an effort to get poliphenol as antioxidant compound had been done. Purification of fermented spinach extract suspension was carried out through microfiltration (MF) membrane (pore size 0.15 µm) fitted in dead-end Stirred Ultrafiltration Cell (SUFC) mode at fixed condition (stirrer rotation 400 rpm, room temperature, pressure 40 psia). Result of the experimental activity showed that long fermentation time increased total acids, total polyphenol and Total Plate Count (TPC), and decreased total solids and reducing sugar in biomass. The optimal fermentation time was reached for 2 weeks with total polyphenol recovery increasing of 92.76 % from before and after fermentation. On this optimal fermentation time, biomass had identified galic acid with relative intensity of 8 %, while as polyphenol monomer was resulted 5 kinds of polyphenol compounds with total intensity 27.97 % and molecular weight (MW) 191.1736, 193.1871 and 194.2170 at T2.5, T2.86 and T3.86. Long fermentation time increased functional properties of polyphenol as antioxidant.
Boiling regimes of impacting drops on a heated substrate under reduced pressure
NASA Astrophysics Data System (ADS)
van Limbeek, Michiel A. J.; Hoefnagels, Paul B. J.; Shirota, Minori; Sun, Chao; Lohse, Detlef
2018-05-01
We experimentally investigate the boiling behavior of impacting ethanol drops on a heated smooth sapphire substrate at pressures ranging from P =0.13 bar to atmospheric pressure. We employ frustrated total internal reflection imaging to study the wetting dynamics of the contact between the drop and the substrate. The spreading drop can be in full contact (contact boiling), it can partially touch (transition boiling), or the drop can be fully levitated (Leidenfrost boiling). We show that the temperature of the boundary between contact and transition boiling shows at most a weak dependence on the impact velocity, but a significant decrease with decreasing ambient gas pressure. A striking correspondence is found between the temperature of this boundary and the static Leidenfrost temperature for all pressures. We therefore conclude that both phenomena share the same mechanism and are dominated by the dynamics taking place at the contact line. On the other hand, the boundary between transition boiling and Leidenfrost boiling, i.e., the dynamic Leidenfrost temperature, increases for increasing impact velocity for all ambient gas pressures. Moreover, the dynamic Leidenfrost temperature coincides for pressures between P =0.13 and 0.54 bar, whereas for atmospheric pressure the dynamic Leidenfrost temperature is slightly elevated. This indicates that the dynamic Leidenfrost temperature is at most weakly dependent on the enhanced evaporation by the lower saturation temperature of the liquid.
Zhang, Xia; Li, Yuqian; Wang, Fang; Zang, Jianguo; Liu, Xiaotian; Zhang, Honglei; Yang, Kaili; Zhang, Gongyuan; Wang, Chongjian
2018-06-07
We examined the independent and cumulative associations of resting heart rate and pulse pressure with metabolic syndrome in Chinese rural population based on epidemiological research. A total of 38,708 participants were derived from the Henan Rural Cohort study. Restricted cubic splines and logistic regression model were used to estimate the odds ratios and 95% confidence intervals of metabolic syndrome risk in relation to resting heart rate and pulse pressure. After adjusting for potential confounders, the odds ratio (95% confidence intervals) of resting heart rate and pulse pressure in the highest quartile with the risk of metabolic syndrome were 1.59 (1.48-1.70) and1.81 (1.67-1.95), respectively. Simultaneously, the cumulative effect analysis indicated that the adjusted the odd ratio of resting heart rate and pulse pressure in the highest quartile was 2.89 (2.40-3.47). Furthermore, there was a significantly additive interaction between resting heart rate and pulse pressure on the risk of metabolic syndrome. Increased resting heart rate and pulse pressure are associated with the higher risk of metabolic syndrome as well as the influences of resting heart rate with pulse pressure might cumulatively increase the risk of metabolic syndrome. However, the potential clinical application remains to be determined. Copyright © 2018. Published by Elsevier B.V.
Use of a pitot probe for determining wing section drag in flight
NASA Technical Reports Server (NTRS)
Saltzman, E. J.
1975-01-01
A wake traversing probe was used to obtain section drag and wake profile data from the wing of a sailplane. The transducer sensed total pressure defect in the wake as well as freestream total pressure on both sides of the sensing element when the probe moved beyond the wake. Profiles of wake total pressure defects plotted as a function of distance above and below the trailing edge plane were averaged for calculating section drag coefficients for flights at low dynamic pressures.
Kuznetsova, Tatiana; D’hooge, Jan; Kloch-Badelek, Malgorzata; Sakiewicz, Wojciech; Thijs, Lutgarde; Staessen, Jan A.
2013-01-01
Background To understand better the mechanism of left ventricular (LV) remodeling related to hypertension, it is important to evaluate LV function in relation to the changes in loading conditions. The aim of this study was to investigate changes in conventional ventricular-arterial coupling indexes, LV strain, and a new index reflecting regional myocardial work assessed noninvasively at rest and during isometric exercise in a random sample including participants with normal blood pressure and those with hypertension. Methods A total of 148 participants (53.4% women; mean age, 52.0 years; 39.2% with hypertension) underwent simultaneous echocardiographic and arterial data acquisition at rest and during increased afterload (handgrip exercise). End-systolic pressure was determined from the carotid pulse wave. Arterial elastance (Ea) and LV elastance (Ees) were calculated as end-systolic pressure/stroke volume and end-systolic pressure/end-systolic volume. Doppler tissue imaging and two-dimensional speckle tracking were used to derive LV longitudinal strain. Regional myocardial work (ejection work density [EWD]) was the area of the pressure-strain loop during ejection. Results At rest, with adjustments applied, Ees (3.06 vs 3.71 mmHg/mL,P = .0003), Ea/Ees (0.54 vs 0.47,P=.002) and EWD (670 vs 802 Pa/m2, P = .0001) differed significantly between participants with normal blood pressure and those with hypertension. During handgrip exercise, Ea and Ea/Ees significantly increased (P < .0001) in both groups. Doppler tissue imaging and two-dimensional LV strain decreased in participants with hypertension (P ≤ .008). Only in subjects with normal blood pressure EWD significantly increased (+14.7%, P = .0009). Conclusions Although patients with hypertension compared with those with normal blood pressure have increased LV systolic stiffness and regional myocardial work to match arterial load at rest, they might have diminished cardiac reserve to increase myocardial performance, as estimated by EWD during isometric exercise. PMID:22622108
NASA Astrophysics Data System (ADS)
Erum, Nazia; Azhar Iqbal, Muhammad
2017-12-01
The effect of pressure variation on structural, electronic, elastic, mechanical, optical and thermodynamic characteristics of cubic SrNaF3 fluoroperovskite have been investigated by employing first-principles method within the framework of gradient approximation (GGA). For the total energy calculations, we have used the full-potential linearized augmented plane wave (FP-LAPW) method. Thermodynamic properties are computed in terms of quasi-harmonic Debye model. The pressure effects are determined in the range of 0-25 GPa, in which mechanical stability of SrNaF3 fluoroperovskite remains valid. A prominent decrease in lattice constant and bonds length is observed with the increase in pressure from 0 to 25 GPa. The effect of increase in pressure on band structure calculations with GGA and GGA plus Tran-Blaha modified Becke-Johnson (TB-mBJ) potential reveals a predominant characteristic associated with widening of bandgap. The influence of pressure on set of isotropic elastic parameters and their related properties are numerically estimated for SrNaF3 polycrystalline aggregate. Apart of linear dependence of elastic coefficients, transition from brittle to ductile behavior is observed as pressure is increased from 0 to 25 GPa. We have successfully obtained variation of lattice constant, volume expansion, bulk modulus, Debye temperature and specific heat capacities with pressure and temperature in the range of 0-25 GPa and 0-600 K. All the calculated optical properties such as the complex dielectric function ɛ(ω), optical conductivity σ(ω), energy loss function L(ω), absorption coefficient α(w), refractive index n(ω), reflectivity R(ω), and effective number of electrons n eff, via sum rules shift towards the higher energies under the application of pressure.
Performance of a Model Rich Burn-quick Mix-lean Burn Combustor at Elevated Temperature and Pressure
NASA Technical Reports Server (NTRS)
Peterson, Christopher O.; Sowa, William A.; Samuelsen, G. S.
2002-01-01
As interest in pollutant emission from stationary and aero-engine gas turbines increases, combustor engineers must consider various configurations. One configuration of increasing interest is the staged, rich burn - quick mix - lean burn (RQL) combustor. This report summarizes an investigation conducted in a recently developed high pressure gas turbine combustor facility. The model RQL combustor was plenum fed and modular in design. The fuel used for this study is Jet-A which was injected from a simplex atomizer. Emission (CO2, CO, O2, UHC, NOx) measurements were obtained using a stationary exit plane water-cooled probe and a traversing water-cooled probe which sampled from the rich zone exit and the lean zone entrance. The RQL combustor was operated at inlet temperatures ranging from 367 to 700 K, pressures ranging from 200 to 1000 kPa, and combustor reference velocities ranging from 10 to 20 m/s. Variations were also made in the rich zone and lean zone equivalence ratios. Several significant trends were observed. NOx production increased with reaction temperature, lean zone equivalence ratio and residence time and decreased with increased rich zone equivalence ratio. NOx production in the model RQL combustor increased to the 0.4 power with increased pressure. This correlation, compared to those obtained for non-staged combustors (0.5 to 0.7), suggests a reduced dependence on NOx on pressure for staged combustors. Emissions profiles suggest that rich zone mixing is not uniform and that the rich zone contributes on the order of 16 percent to the total NOx produced.
Atmospheric pressure atomic layer deposition of Al₂O₃ using trimethyl aluminum and ozone.
Mousa, Moataz Bellah M; Oldham, Christopher J; Parsons, Gregory N
2014-04-08
High throughput spatial atomic layer deposition (ALD) often uses higher reactor pressure than typical batch processes, but the specific effects of pressure on species transport and reaction rates are not fully understood. For aluminum oxide (Al2O3) ALD, water or ozone can be used as oxygen sources, but how reaction pressure influences deposition using ozone has not previously been reported. This work describes the effect of deposition pressure, between ∼2 and 760 Torr, on ALD Al2O3 using TMA and ozone. Similar to reports for pressure dependence during TMA/water ALD, surface reaction saturation studies show self-limiting growth at low and high pressure across a reasonable temperature range. Higher pressure tends to increase the growth per cycle, especially at lower gas velocities and temperatures. However, growth saturation at high pressure requires longer O3 dose times per cycle. Results are consistent with a model of ozone decomposition kinetics versus pressure and temperature. Quartz crystal microbalance (QCM) results confirm the trends in growth rate and indicate that the surface reaction mechanisms for Al2O3 growth using ozone are similar under low and high total pressure, including expected trends in the reaction mechanism at different temperatures.
NASA Technical Reports Server (NTRS)
Opila, Elizabeth J.; Fox, Dennis S.; Jacobson, Nathan S.
1997-01-01
A high-pressure sampling mass spectrometer was used to detect the volatile species formed from SiO2 at temperatures between 1200C and 1400C in a flowing water vapor/oxygen gas mixture at 1 bar total pressure. The primary vapor species identified was Si(OH)4. The fragment ion Si(OH)3+,' was observed in quantities 3 to 5 times larger than the parent ion Si(OH)4+. The Si(OH)3+ intensity was found to have a small temperature dependence and to increase with the water vapor partial pressure as expected. In addition, SiO(OH)+ believed to be a fragment of SiO(OH)2, was observed. These mass spectral results were compared to the behavior of silicon halides.
Fioretto, F; Cruz, C; Largeteau, A; Sarli, T A; Demazeau, G; El Moueffak, A
2005-08-01
We studied the action of high pressure processing on the inactivation of two foodborne pathogens, Staphylococcus aureus ATCC 6538 and Salmonella enteritidis ATCC 13076, suspended in a culture medium and inoculated into caviar samples. The baroresistance of the two pathogens in a tryptic soy broth suspension at a concentration of 10(8)-10(9) colony-forming units/ml was tested for continuous and cycled pressurization in the 150- to 550-MPa range and for 15-min treatments at room temperature. The increase of cycle number permitted the reduction of the pressure level able to totally inactivate both microorganisms in the tryptic soy broth suspension, whereas the effect of different procedure times on complete inactivation of the microorganisms inoculated into caviar was similar.
Foot pressures during gait: a comparison of techniques for reducing pressure points.
Lawless, M W; Reveal, G T; Laughlin, R T
2001-07-01
Various methods have been used to redistribute plantar surface foot pressure in patients with foot ulcers. This study was conducted to determine the effectiveness of four modalities (fracture walker, fracture walker with insert, and open and closed toe total contact casts) in reducing plantar foot pressure. Ten healthy, normal volunteer subjects had an F-scan sensor (ultra thin shoe insert pressure monitor) placed under the right foot. They then ambulated on a flat surface, maintaining their normal gait. Dynamic plantar pressures were averaged over 10 steps at four different sites (plantar surface of great toe, first metatarsal head, base of fifth metatarsal, and plantar heel). All subjects repeated this sequence under five different testing conditions (barefoot, with a fracture walker, fracture walker with arch support insert, open and closed toe total contact cast). Each subject's barefoot pressures were then compared with the pressures during the different modalities. All four treatment modalities significantly reduced (p < 0.05) plantar pressure at the first metatarsal head (no method was superior). The fracture walker, fracture walker with insert, and open toe total contact cast significantly reduced pressure at the heel. Pressures at the base of the fifth metatarsal and great toe were not significantly reduced with any treatment form. The fracture walker, with and without arch support, and total contact cast can effectively reduce plantar pressure at the heel and first metatarsal head.
TRPV4 participates in pressure-induced inhibition of renin secretion by juxtaglomerular cells.
Seghers, François; Yerna, Xavier; Zanou, Nadège; Devuyst, Olivier; Vennekens, Rudi; Nilius, Bernd; Gailly, Philippe
2016-12-15
Increase in blood pressure in the renal afferent arteriole is known to induce an increase in cytosolic calcium concentration ([Ca 2+ ] i ) of juxtaglomerular (JG) cells and to result in a decreased secretion of renin. Mechanical stimulation of As4.1 JG cells induces an increase in [Ca 2+ ] i that is inhibited by HC067047 and RN1734, two inhibitors of TRPV4, or by siRNA-mediated repression of TRPV4. Inhibition of TRPV4 impairs pressure-induced decrease in renin secretion. Compared to wild-type mice, Trpv4 -/- mice present increased resting plasma levels of renin and aldosterone and present a significantly altered pressure-renin relationship. We suggest that TRPV4 channel participates in mechanosensation at the juxtaglomerular apparatus. The renin-angiotensin system is a crucial blood pressure regulation system. It consists of a hormonal cascade where the rate-limiting enzyme is renin, which is secreted into the blood flow by renal juxtaglomerular (JG) cells in response to low pressure in the renal afferent arteriole. In contrast, an increase in blood pressure results in a decreased renin secretion. This is accompanied by a transitory increase in [Ca 2+ ] i of JG cells. The inverse relationship between [Ca 2+ ] i and renin secretion has been called the 'calcium paradox' of renin release. How increased pressure induces a [Ca 2+ ] i transient in JG cells, is however, unknown. We observed that [Ca 2+ ] i transients induced by mechanical stimuli in JG As4.1 cells were completely abolished by HC067047 and RN1734, two inhibitors of TRPV4. They were also reduced by half by siRNA-mediated repression of TRPV4 but not after repression or inhibition of TRPV2 or Piezo1 ion channels. Interestingly, the stimulation of renin secretion by the adenylate cyclase activator forskolin was totally inhibited by cyclic stretching of the cells. This effect was mimicked by stimulation with GSK1016790A and 4αPDD, two activators of TRPV4 and inhibited in the presence of HC067047. Moreover, in isolated perfused kidneys from Trpv4 -/- mice, the pressure-renin relationship was significantly altered. In vivo, Trpv4 -/- mice presented increased plasma levels of renin and aldosterone compared to wild-type mice. Altogether, our results suggest that TRPV4 is involved in the pressure-induced entry of Ca 2+ in JG cells, which inhibits renin release and allows the negative feedback regulation on blood pressure. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.
Carvalho, Nadja C; Güldner, Andreas; Beda, Alessandro; Rentzsch, Ines; Uhlig, Christopher; Dittrich, Susanne; Spieth, Peter M; Wiedemann, Bärbel; Kasper, Michael; Koch, Thea; Richter, Torsten; Rocco, Patricia R; Pelosi, Paolo; de Abreu, Marcelo Gama
2014-11-01
To assess the effects of different levels of spontaneous breathing during biphasic positive airway pressure/airway pressure release ventilation on lung function and injury in an experimental model of moderate acute respiratory distress syndrome. Multiple-arm randomized experimental study. University hospital research facility. Thirty-six juvenile pigs. Pigs were anesthetized, intubated, and mechanically ventilated. Moderate acute respiratory distress syndrome was induced by repetitive saline lung lavage. Biphasic positive airway pressure/airway pressure release ventilation was conducted using the airway pressure release ventilation mode with an inspiratory/expiratory ratio of 1:1. Animals were randomly assigned to one of four levels of spontaneous breath in total minute ventilation (n = 9 per group, 6 hr each): 1) biphasic positive airway pressure/airway pressure release ventilation, 0%; 2) biphasic positive airway pressure/airway pressure release ventilation, > 0-30%; 3) biphasic positive airway pressure/airway pressure release ventilation, > 30-60%, and 4) biphasic positive airway pressure/airway pressure release ventilation, > 60%. The inspiratory effort measured by the esophageal pressure time product increased proportionally to the amount of spontaneous breath and was accompanied by improvements in oxygenation and respiratory system elastance. Compared with biphasic positive airway pressure/airway pressure release ventilation of 0%, biphasic positive airway pressure/airway pressure release ventilation more than 60% resulted in lowest venous admixture, as well as peak and mean airway and transpulmonary pressures, redistributed ventilation to dependent lung regions, reduced the cumulative diffuse alveolar damage score across lungs (median [interquartile range], 11 [3-40] vs 18 [2-69]; p < 0.05), and decreased the level of tumor necrosis factor-α in ventral lung tissue (median [interquartile range], 17.7 pg/mg [8.4-19.8] vs 34.5 pg/mg [29.9-42.7]; p < 0.05). Biphasic positive airway pressure/airway pressure release ventilation more than 0-30% and more than 30-60% showed a less consistent pattern of improvement in lung function, inflammation, and damage compared with biphasic positive airway pressure/airway pressure release ventilation more than 60%. In this model of moderate acute respiratory distress syndrome in pigs, biphasic positive airway pressure/airway pressure release ventilation with levels of spontaneous breath higher than usually seen in clinical practice, that is, more than 30% of total minute ventilation, reduced lung injury with improved respiratory function, as compared with protective controlled mechanical ventilation.
Loring, Stephen H; O'Donnell, Carl R; Butler, James P; Lindholm, Peter; Jacobson, Francine; Ferrigno, Massimo
2007-03-01
Throughout life, most mammals breathe between maximal and minimal lung volumes determined by respiratory mechanics and muscle strength. In contrast, competitive breath-hold divers exceed these limits when they employ glossopharyngeal insufflation (GI) before a dive to increase lung gas volume (providing additional oxygen and intrapulmonary gas to prevent dangerous chest compression at depths recently greater than 100 m) and glossopharyngeal exsufflation (GE) during descent to draw air from compressed lungs into the pharynx for middle ear pressure equalization. To explore the mechanical effects of these maneuvers on the respiratory system, we measured lung volumes by helium dilution with spirometry and computed tomography and estimated transpulmonary pressures using an esophageal balloon after GI and GE in four competitive breath-hold divers. Maximal lung volume was increased after GI by 0.13-2.84 liters, resulting in volumes 1.5-7.9 SD above predicted values. The amount of gas in the lungs after GI increased by 0.59-4.16 liters, largely due to elevated intrapulmonary pressures of 52-109 cmH(2)O. The transpulmonary pressures increased after GI to values ranging from 43 to 80 cmH(2)O, 1.6-2.9 times the expected values at total lung capacity. After GE, lung volumes were reduced by 0.09-0.44 liters, and the corresponding transpulmonary pressures decreased to -15 to -31 cmH(2)O, suggesting closure of intrapulmonary airways. We conclude that the lungs of some healthy individuals are able to withstand repeated inflation to transpulmonary pressures far greater than those to which they would normally be exposed.
Weigel, Julia K; Steinmann, Daniel; Emerich, Philipp; Stahl, Claudius A; v Elverfeldt, Dominik; Guttmann, Josef
2011-02-01
Perfluorocarbons (PFC) are biologically and chemically inert fluids with high oxygen and CO(2) carrying capacities. Their use as liquid intrapulmonary gas carriers during liquid ventilation has been investigated. We established a method of high resolution 3D-(19)F-MRI of the totally PFC-filled lung. The goal of this study was to investigate longitudinal and circumferential airway strain in the setting of increasing airway pressures on 3D-(19)F-MR images of the PFC-filled lung. Sixteen female Wistar rats were euthanized and the liquid perfluorocarbon FC-84 instilled into their lungs. 3D-(19)F-MRI was performed at various intrapulmonary pressures. Measurements of bronchial length and cross-sectional area were obtained from transversal 2D images for each pressure range. Changes in bronchial area were used to determine circumferential strain, while longitudinal strain was calculated from changes in bronchial length. Our method of 3D-(19)F-MRI allowed clear visualization of the great bronchi. Longitudinal strain increased significantly up to 31.1 cmH(2)O. The greatest strain could be found in the range of low airway pressures. Circumferential strain increased strongly with the initial pressure rise, but showed no significant changes above 10.4 cmH(2)O. Longitudinal strain was generally higher in distal airways, while circumferential strain showed no difference. Analysis of mechanical characteristics showed that longitudinal and circumferential airway expansion occurred in an anisotropic fashion. Whereas longitudinal strain still increased with higher pressures, circumferential strain quickly reached a 'strain limit'. Longitudinal strain was higher in distal bronchi, as dense PFCs gravitate to dependent, in this case to dorso-basal parts of the lung, acting as liquid positive end expiratory pressure.
Proximate nutritional composition of CELSS crops grown at different CO2 partial pressures
NASA Technical Reports Server (NTRS)
Wheeler, R. M.; Mackowiak, C. L.; Sager, J. C.; Knott, W. M.; Berry, W. L.
1994-01-01
Two Controlled Ecological Life Support System (CELSS) candidate crops, soybean (Glycine max) and potato (Solanum tuberosum), were grown hydroponically in controlled environments maintained at carbon dioxide (CO2) partial pressures ranging from 0.05 to 1.00 kPa (500 to 10,000 ppm at 101 kPa atmospheric pressure). Plants were harvested at maturity (90 days for soybean and 105 days for potato) and all tissues analyzed for proximate nutritional composition (i.e. protein, fat, carbohydrate, crude fiber, and ash content). Soybean seed ash and crude fiber were higher and carbohydrate was lower than values reported for field-grown seed. Potato tubers showed little difference from field-grown tubers. Crude fiber of soybean stems and leaves increased with increased CO2, as did soybean leaf protein (total nitrogen). Potato leaf and stem (combined) protein levels also increased with increased CO2, while leaf and stem carbohydrates decreased. Values for leaf and stem protein and ash were higher than values generally reported for field-grown plants for both species. Results suggest that CO2 partial pressure should have little influence on proximate composition of potato tubers or soybean seed, but that high ash and protein levels might be expected from leaves and stems of crops grown in controlled environments of a CELSS.
The Type of Fat Ingested at Breakfast Influences the Plasma Lipid Profile of Postmenopausal Women
Morillas-Ruiz, J. M.; Delgado-Alarcon, J. M.; Rubio-Perez, J. M.; Albaladejo Oton, M. D.
2014-01-01
To assess whether the type of fat ingested at breakfast can modify the plasma lipid profile and other cardiovascular risk variables in postmenopausal women at risk of cardiovascular disease, a longitudinal, randomized, and crossover study was carried out with postmenopausal women at risk of CVD. They were randomly assigned to eat each type of breakfast during one month: 6 study periods (breakfast with the same composition plus butter/margarine/virgin olive oil) separated by two washout periods. On the first and last days of each study period, weight, arterial blood pressure, heart rate, and body mass index were recorded in fasting conditions and a blood sample was collected to measure plasma lipid profile. When comparing final values to baseline values, we only found out statistically significant differences on plasma lipid profiles. Butter-based breakfast increased total cholesterol and HDL, while margarine-based breakfast decreased total cholesterol and LDL and increased HDL. After the olive oil-based breakfast intake, a tendency towards a decrease of total cholesterol and LDL levels and an increase of HDL levels was observed. No statistically significant differences were observed in triglycerides levels, BMI, and arterial pressure in any breakfast type. The margarine-based breakfast was the only one which significantly increased the percentage of volunteers with optimal lipid profiles. The polyunsaturated fat at breakfast has improved the plasma lipid profile in the analyzed sample population, suggesting that PUFA-based breakfast can be advisable in women at risk of CVD. PMID:25136625
Ari, Seyhmus; Cingü, Abdullah Kürsat; Sahin, Alparslan; Çinar, Yasin; Çaça, Ihsan
2012-01-01
To evaluate how different energy levels of Nd:YAG laser posterior capsulotomy affect best-corrected visual acuity (BCVA), intraocular pressure (IOP), and macular thickness of patients with posterior capsule opacification. Thirty eyes of 30 patients with posterior capsule opacification following phacoemulsification were enrolled in the study. Patients were classified according to total energy used during Nd:YAG laser capsulotomy (≤ 80 mJ = group I, > 80 mJ = group II). Mean total energy levels were 58 ± 18 mJ (range: 14 to 80 mJ) in group I and 117 ± 36 mJ (range: 84 to 200 mJ) in group II. BCVA at 1 week preoperatively and 1 and 3 months postoperatively was significantly better compared to preoperative BCVA in both groups (P < .001). In group I, IOP increased 1 week postoperatively (P = .007) and declined to preoperative levels at 1 month. In group II, IOP increased 1 week postoperatively (P = .001) and did not return to preoperative levels during 3 months of follow-up (P = .04). Both groups had increased macular thickness compared to preoperative levels, but group II measurements were significantly higher 1 week and 1 month postoperatively compared to group I (P = .004 and .03, respectively). Increased IOP and macular thickness are inevitable after Nd:YAG laser capsulotomy, but the severity and duration are less when a total energy level less than 80 mJ is used. Copyright 2012, SLACK Incorporated.
Suka, Machi; Yoshida, Katsumi; Kawai, Tadashi; Aoki, Yoshikazu; Yamane, Noriyuki; Yamauchi, Kuniaki
2005-07-01
To determine age- and sex-specific reference intervals for 10 health examination items in Japanese adults. Health examination data were accumulated from 24 different prefectural health service associations affiliated with the Japan Association of Health Service. Those who were non-smokers, drank less than 7 days/week, and had a body mass index of 18.5-24.9kg/m2 were sampled as a reference population (n = 737,538; 224,947 men and 512,591 women). After classified by age and sex, reference intervals for 10 health examination items (systolic blood pressure, diastolic blood pressure, total cholesterol, triglyceride, glucose, uric acid, AST, ALT, gamma-GT, and hemoglobin) were estimated using the parametric and nonparametric methods. In every item except for hemoglobin, men had higher reference intervals than women. Systolic blood pressure, total cholesterol, and glucose showed an upward trend in values with increasing age. Hemoglobin showed a downward trend in values with increasing age. Triglyceride, ALT, and gamma-GT reached a peak in middle age. Overall, parametric estimates showed narrower reference intervals than non-parametric estimates. Reference intervals vary with age and sex. Age- and sex-specific reference intervals may contribute to better assessment of health examination data.
The Rise and Fall of Industrial Agriculture
ERIC Educational Resources Information Center
Geno, Larry M.
1976-01-01
This article analyzes the evolution of industrial agriculture in Canada. Population pressures and technology caused the development of industrial agriculture. Although total crop yields have increased, energy efficiency and nutritional quality have decreased. Also intensive agriculture has degraded the soil and lowered air and water qualities. (MR)
White-collar workers' hemodynamic responses during working hours.
Liu, Xinxin; Iwakiri, Kazuyuki; Sotoyama, Midori
2017-08-08
In the present study, two investigations were conducted at a communication center, to examine white-collar workers' hemodynamic responses during working hours. In investigation I, hemodynamic responses were measured on a working day; and in investigation II, cardiovascular responses were verified on both working and non-working days. In investigation I, blood pressure, cardiac output, heart rate, stroke volume, and total peripheral resistance were measured in 15 workers during working hours (from 9:00 am to 18:00 pm) on one working day. Another 40 workers from the same workplace participated in investigation II, in which blood pressure and heart rate were measured between the time workers arose in the morning until they went to bed on 5 working days and 2 non-working days. The results showed that blood pressure increased and remained at the same level during working hours. The underlying hemodynamics of maintaining blood pressure, however, changed between the morning and the afternoon on working days. Cardiac responses increased in the afternoon, suggesting that cardiac burdens increase in the afternoon on working days. The present study suggested that taking underlying hemodynamic response into consideration is important for managing the work-related cardiovascular burden of white-collar workers.
White-collar workers’ hemodynamic responses during working hours
LIU, Xinxin; IWAKIRI, Kazuyuki; SOTOYAMA, Midori
2017-01-01
In the present study, two investigations were conducted at a communication center, to examine white-collar workers’ hemodynamic responses during working hours. In investigation I, hemodynamic responses were measured on a working day; and in investigation II, cardiovascular responses were verified on both working and non-working days. In investigation I, blood pressure, cardiac output, heart rate, stroke volume, and total peripheral resistance were measured in 15 workers during working hours (from 9:00 am to 18:00 pm) on one working day. Another 40 workers from the same workplace participated in investigation II, in which blood pressure and heart rate were measured between the time workers arose in the morning until they went to bed on 5 working days and 2 non-working days. The results showed that blood pressure increased and remained at the same level during working hours. The underlying hemodynamics of maintaining blood pressure, however, changed between the morning and the afternoon on working days. Cardiac responses increased in the afternoon, suggesting that cardiac burdens increase in the afternoon on working days. The present study suggested that taking underlying hemodynamic response into consideration is important for managing the work-related cardiovascular burden of white-collar workers. PMID:28428502
Radiant heat transfer from flames in a single tubular turbojet combustor / Leonard Topper
NASA Technical Reports Server (NTRS)
Topper, Leonard
1952-01-01
An experimental investigation of thermal radiation from the flame of a single tubular turbojet-engine combustor to the combustor liner is presented. The effects of combustor inlet-air pressure, air mass flow, and fuel-air ratio on the radiant intensity and the temperature and emissivity of the flame are reported. The total radiation of the "luminous" flames (containing incandescent soot particles) was much greater (4 to 21 times) than the "nonluminous" molecular radiation. The intensity of radiation from the flame increased rapidly with an increase in combustor inlet-air pressure; it was affected to a lesser degree by variations in fuel-air ratio and air mass flow.
High beta plasma operation in a toroidal plasma producing device
Clarke, John F.
1978-01-01
A high beta plasma is produced in a plasma producing device of toroidal configuration by ohmic heating and auxiliary heating. The plasma pressure is continuously monitored and used in a control system to program the current in the poloidal field windings. Throughout the heating process, magnetic flux is conserved inside the plasma and the distortion of the flux surfaces drives a current in the plasma. As a consequence, the total current increases and the poloidal field windings are driven with an equal and opposing increasing current. The spatial distribution of the current in the poloidal field windings is determined by the plasma pressure. Plasma equilibrium is maintained thereby, and high temperature, high beta operation results.
Body image and sexual orientation: The experiences of lesbian and bisexual women.
Smith, Marie L; Telford, Elina; Tree, Jeremy J
2017-02-01
Western cultures promote a thin and curvaceous ideal body size that most women find difficult to achieve by healthy measures, resulting in poor body image and increased risk for eating pathology. Research focusing on body image in lesbian and bisexual women has yielded inconsistent results. In total, 11 lesbian and bisexual women were interviewed regarding their experiences with body image. Interpretative phenomenological analysis revealed that these women experienced similar mainstream pressures to conform to a thin body ideal. Furthermore, participants perceived additional pressure to conform to heteronormative standards of beauty since the normalisation of homosexuality and the increase in Lesbian, Gay, Bisexual and Transgender representation in mainstream media.
NASA Technical Reports Server (NTRS)
Goodwin, Lisa Ann; Frey, Mary Anne Bassett; Merz, Marion P.; Alford, William R.
1987-01-01
Kennedy Space Center (KSC) employees are reported to be at high risk for coronary heart disease (CHD). Risk factors for CHD include high serum total cholesterol levels, low levels of high-density lipoprotein cholesterol (HDLC), elevated triglyceride, smoking, inactivity, high blood pressure, being male, and being older. Higher dietary and/or serum calcium Ca(++) may be related to a lower risk for CHD. Fifty men and 37 women participated. Subjects were tested in the morning after fasting 12 hours. Information relative to smoking and exercise habits was obtained; seated blood pressures were measured; and blood drawn. KCS men had higher risk values than KCS women as related to HDLC, triglycerides, systolic blood pressure, and diastolic blood pressure. Smoking and nonsmoking groups did not differ for other risk factors or for serum Ca(++) levels. Exercise and sedentary groups differed in total cholesterol and triglyceride levels. Serum Ca(++) levels were related to age, increasing with age in the sedentary group and decreasing in the exercisers, equally for men and women. It is concluded that these relationships may be significant to the risk of CHD and/or the risk of bone demineralization in an aging population.
NASA Astrophysics Data System (ADS)
Beeler, N. M.; Lockner, D. A.; Kilgore, B. D.; Moore, D. E.
2011-12-01
Localized slip during earthquakes, e.g., at 1 m/s for a few seconds, should produce enough thermal energy to melt rock or pressurize pore fluid and drastically reduce fault strength (Sibson, Nature Phys. Sci., 1973. Sibson, Geophys. J. R. Astr. Soc., 1975). Expected changes in earthquake source properties for events with large enough temperature change to induce melting or fluid pressurization include an increase in stress drop, a possible increase in low frequency content of the radiated energy and an increase in the ratio of radiated energy to seismic moment. Such changes with increasing moment, while expected, are not observed seismologically and the role of thermal weakening during large earthquakes remains unknown. To investigate the effect of the onset of thermal weakening on earthquake source properties such as stress drop, slip velocity, weakening distance, and apparent stress, we have conducted stick-slip experiments at confining pressures between 50 and 400 MPa on initially bare rock surfaces of Westerly granite (Lockner et al., Eos Trans. Am. Geophys. Un. T23A-2245, 2010). These conditions span a transition from frictional sliding, producing dry comminuted fault gouge and fractional stress drops at lower confining pressure, to shear induced melting with complete stress drop at the highest pressures. The confining pressure, axial stress and displacement, are measured as in standard faulting tests. Temperature is monitored with a thermocouple ~2.5 mm from the fault. Rapid motions of the fault are inferred from independent recordings of the acceleration and velocity of the loading piston using an accelerometer and a laser Doppler vibrometer. Slip velocity, and event duration increase with stress drop. Stress drops vary from less than 10 to greater than 400 MPa. Durations are between 0.1 and 0.5 ms and average sliding velocities range from <1 to > 10 m/s. Total stress drop is associated with slip and shear stress sufficient to increase the entire shear zone temperature to the melting point of feldspar, but melt is also found in samples subjected to smaller stress drops, suggesting heating to somewhat lower temperature. Stress and slip constrain the total energy; the temperature measurements constrain the energy associated with frictional heating and the heat of fusion, while the velocity measurements allow an estimate of the radiated energy. Using these constraints and models of shear-induced melting we examine changes in event source properties across the transition to shear melting.
Unsteady Loss in the Stator Due to the Incoming Rotor Wake in a Highly-Loaded Transonic Compressor
NASA Technical Reports Server (NTRS)
Hah, Chunill
2015-01-01
The present paper reports an investigation of unsteady loss generation in the stator due to the incoming rotor wake in an advanced GE transonic compressor design with a high-fidelity numerical method. This advanced compressor with high reaction and high stage loading has been investigated both experimentally and analytically in the past. The measured efficiency in this advanced compressor is significantly lower than the design intention/goal. The general understanding is that the current generation of compressor design/analysis tools miss some important flow physics in this modern compressor design. To pinpoint the source of the efficiency miss, an advanced test with a detailed flow traverse was performed for the front one and a half stage at the NASA Glenn Research Center. Detailed data-match analysis by GE identified an unexpected high loss generation in the pressure side of the stator passage. Higher total temperature and lower total pressure are measured near the pressure side of the stator. Various analyses based on the RANS and URANS of the compressor stage do not calculate the measured higher total temperature and lower total pressure on the pressure side of the stator. In the present paper, a Large Eddy Simulation (LES) is applied to find the fundamental mechanism of this unsteady loss generation in the stator due to the incoming rotor wake. The results from the LES were first compared with the NASA test results and the GE interpretation of the test data. LES calculates lower total pressure and higher total temperature on the pressure side of the stator, as the measured data showed, resulting in large loss generation on the pressure side of the stator. Detailed examination of the unsteady flow field from LES shows that the rotor wake, which has higher total temperature and higher total pressure relative to the free stream, interacts quite differently with the pressure side of the blade compared to the suction side of the blade. The higher temperature in the wake remains high as the wake passes through the pressure side of the blade. On the other hand, the total temperature diffuses as it passes through near the suction surface. For the presently investigated compressor, the classical intra-stator wake transport to the pressure side of the blade by the slip velocity in the wake seems to be minor. The main causes of this phenomenon are three-dimensional unsteady vortex interactions near the blade surface. The stabilizing effect of the concave curvature on the suction side keeps the rotor wake thin. On the other hand, the destabilizing effect of the convex curvature of the pressure side makes the rotor wake thicker, which results in a higher total temperature measurement at the stator exit. Additionally, wake stretching through the stator seems to contribute to the redistribution of the total temperature and the loss generation.
Alumina Volatility in Water Vapor at Elevated Temperatures: Application to Combustion Environments
NASA Technical Reports Server (NTRS)
Opila, Elizabeth J.; Myers, Dwight L.
2003-01-01
The volatility of alumina in high temperature water vapor was determined by measuring weight loss of sapphire coupons at temperatures between 1250 and 1500 C, water vapor partial pressures between 0.15 and 0.68 atm in oxygen, at one atmosphere total pressure, and a gas velocity of 4.4 centimeters per second. The variation of the volatility with water vapor partial pressure was consistent with Al(OH)3(g) formation. The enthalpy of reaction to form Al(OH)3(g) from alumina and water vapor was found to be 210 plus or minus 20 kJ/mol. Surface rearrangement of ground sapphire surfaces increased with water vapor partial pressure, temperature and volatility rate. Recession rates of alumina due to volatility were determined as a function of water vapor partial pressure and temperature to evaluate limits for use of alumina in long term applications in combustion environments.
On testing models for the pressure-strain correlation of turbulence using direct simulations
NASA Technical Reports Server (NTRS)
Speziale, Charles G.; Gatski, Thomas B.; Sarkar, Sutanu
1992-01-01
Direct simulations of homogeneous turbulence have, in recent years, come into widespread use for the evaluation of models for the pressure-strain correlation of turbulence. While work in this area has been beneficial, the increasingly common practice of testing the slow and rapid parts of these models separately in uniformly strained turbulent flows is shown in this paper to be unsound. For such flows, the decomposition of models for the total pressure-strain correlation into slow and rapid parts is ambiguous. Consequently, when tested in this manner, misleading conclusions can be drawn about the performance of pressure-strain models. This point is amplified by illustrative calculations of homogeneous shear flow where other pitfalls in the evaluation of models are also uncovered. More meaningful measures for testing the performance of pressure-strain models in uniformly strained turbulent flows are proposed and the implications for turbulence modeling are discussed.
Simulated Altitude Performance of Combustor of Westinghouse 19XB-1 Jet-Propulsion Engine
NASA Technical Reports Server (NTRS)
Childs, J. Howard; McCafferty, Richard J.
1948-01-01
A 19XB-1 combustor was operated under conditions simulating zero-ram operation of the 19XB-1 turbojet engine at various altitudes and engine speeds. The combustion efficiencies and the altitude operational limits were determined; data were also obtained on the character of the combustion, the pressure drop through the combustor, and the combustor-outlet temperature and velocity profiles. At altitudes about 10,000 feet below the operational limits, the flames were yellow and steady and the temperature rise through the combustor increased with fuel-air ratio throughout the range of fuel-air ratios investigated. At altitudes near the operational limits, the flames were blue and flickering and the combustor was sluggish in its response to changes in fuel flow. At these high altitudes, the temperature rise through the combustor increased very slowly as the fuel flow was increased and attained a maximum at a fuel-air ratio much leaner than the over-all stoichiometric; further increases in fuel flow resulted in decreased values of combustor temperature rise and increased resonance until a rich-limit blow-out occurred. The approximate operational ceiling of the engine as determined by the combustor, using AN-F-28, Amendment-3, fuel, was 30,400 feet at a simulated engine speed of 7500 rpm and increased as the engine speed was increased. At an engine speed of 16,000 rpm, the operational ceiling was approximately 48,000 feet. Throughout the range of simulated altitudes and engine speeds investigated, the combustion efficiency increased with increasing engine speed and with decreasing altitude. The combustion efficiency varied from over 99 percent at operating conditions simulating high engine speed and low altitude operation to less than 50 percent at conditions simulating operation at altitudes near the operational limits. The isothermal total pressure drop through the combustor was 1.82 times as great as the inlet dynamic pressure. As expected from theoretical considerations, a straight-line correlation was obtained when the ratio of the combustor total pressure drop to the combustor-inlet dynamic pressure was plotted as a function of the ratio of the combustor-inlet air density to the combustor-outlet gas density. The combustor-outlet temperature profiles were, in general, more uniform for runs in which the temperature rise was low and the combustion efficiency was high. Inspection of the combustor basket after 36 hours of operation showed very little deterioration and no appreciable carbon deposits.
Soft x-ray spectroscopy of high pressure liquid.
Qiao, Ruimin; Xia, Yujian; Feng, Xuefei; Macdougall, James; Pepper, John; Armitage, Kevin; Borsos, Jason; Knauss, Kevin G; Lee, Namhey; Allézy, Arnaud; Gilbert, Benjamin; MacDowell, Alastair A; Liu, Yi-Sheng; Glans, Per-Anders; Sun, Xuhui; Chao, Weilun; Guo, Jinghua
2018-01-01
We describe a new experimental technique that allows for soft x-ray spectroscopy studies (∼100-1000 eV) of high pressure liquid (∼100 bars). We achieve this through a liquid cell with a 100 nm-thick Si 3 N 4 membrane window, which is sandwiched by two identical O-rings for vacuum sealing. The thin Si 3 N 4 membrane allows soft x-rays to penetrate, while separating the high-pressure liquid under investigation from the vacuum required for soft x-ray transmission and detection. The burst pressure of the Si 3 N 4 membrane increases with decreasing size and more specifically is inversely proportional to the side length of the square window. It also increases proportionally with the membrane thickness. Pressures > 60 bars could be achieved for 100 nm-thick square Si 3 N 4 windows that are smaller than 65 μm. However, above a certain pressure, the failure of the Si wafer becomes the limiting factor. The failure pressure of the Si wafer is sensitive to the wafer thickness. Moreover, the deformation of the Si 3 N 4 membrane is quantified using vertical scanning interferometry. As an example of the performance of the high-pressure liquid cell optimized for total-fluorescence detected soft x-ray absorption spectroscopy (sXAS), the sXAS spectra at the Ca L edge (∼350 eV) of a CaCl 2 aqueous solution are collected under different pressures up to 41 bars.
Soft x-ray spectroscopy of high pressure liquid
Qiao, Ruimin; Xia, Yujian; Feng, Xuefei; ...
2018-01-01
Here, we describe a new experimental technique that allows for soft x-ray spectroscopy studies (~100-1000 eV) of high pressure liquid (~100 bars). We achieve this through a liquid cell with a 100 nm-thick Si 3N 4 membrane window, which is sandwiched by two identical O-rings for vacuum sealing. The thin Si 3N 4 membrane allows soft x-rays to penetrate, while separating the high-pressure liquid under investigation from the vacuum required for soft x-ray transmission and detection. The burst pressure of the Si 3N 4 membrane increases with decreasing size and more specifically is inversely proportional to the side length ofmore » the square window. It also increases proportionally with the membrane thickness. Pressures > 60 bars could be achieved for 100 nm-thick square Si 3N 4 windows that are smaller than 65 μm. However, above a certain pressure, the failure of the Si wafer becomes the limiting factor. The failure pressure of the Si wafer is sensitive to the wafer thickness. Moreover, the deformation of the Si 3N 4 membrane is quantified using vertical scanning interferometry. As an example of the performance of the high-pressure liquid cell optimized for total-fluorescence detected soft x-ray absorption spectroscopy (sXAS), the sXAS spectra at the Ca L edge (~350 eV) of a CaCl 2 aqueous solution are collected under different pressures up to 41 bars.« less
Soft x-ray spectroscopy of high pressure liquid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qiao, Ruimin; Xia, Yujian; Feng, Xuefei
Here, we describe a new experimental technique that allows for soft x-ray spectroscopy studies (~100-1000 eV) of high pressure liquid (~100 bars). We achieve this through a liquid cell with a 100 nm-thick Si 3N 4 membrane window, which is sandwiched by two identical O-rings for vacuum sealing. The thin Si 3N 4 membrane allows soft x-rays to penetrate, while separating the high-pressure liquid under investigation from the vacuum required for soft x-ray transmission and detection. The burst pressure of the Si 3N 4 membrane increases with decreasing size and more specifically is inversely proportional to the side length ofmore » the square window. It also increases proportionally with the membrane thickness. Pressures > 60 bars could be achieved for 100 nm-thick square Si 3N 4 windows that are smaller than 65 μm. However, above a certain pressure, the failure of the Si wafer becomes the limiting factor. The failure pressure of the Si wafer is sensitive to the wafer thickness. Moreover, the deformation of the Si 3N 4 membrane is quantified using vertical scanning interferometry. As an example of the performance of the high-pressure liquid cell optimized for total-fluorescence detected soft x-ray absorption spectroscopy (sXAS), the sXAS spectra at the Ca L edge (~350 eV) of a CaCl 2 aqueous solution are collected under different pressures up to 41 bars.« less
Parameter sensitivity analysis of a lumped-parameter model of a chain of lymphangions in series.
Jamalian, Samira; Bertram, Christopher D; Richardson, William J; Moore, James E
2013-12-01
Any disruption of the lymphatic system due to trauma or injury can lead to edema. There is no effective cure for lymphedema, partly because predictive knowledge of lymphatic system reactions to interventions is lacking. A well-developed model of the system could greatly improve our understanding of its function. Lymphangions, defined as the vessel segment between two valves, are the individual pumping units. Based on our previous lumped-parameter model of a chain of lymphangions, this study aimed to identify the parameters that affect the system output the most using a sensitivity analysis. The system was highly sensitive to minimum valve resistance, such that variations in this parameter caused an order-of-magnitude change in time-average flow rate for certain values of imposed pressure difference. Average flow rate doubled when contraction frequency was increased within its physiological range. Optimum lymphangion length was found to be some 13-14.5 diameters. A peak of time-average flow rate occurred when transmural pressure was such that the pressure-diameter loop for active contractions was centered near maximum passive vessel compliance. Increasing the number of lymphangions in the chain improved the pumping in the presence of larger adverse pressure differences. For a given pressure difference, the optimal number of lymphangions increased with the total vessel length. These results indicate that further experiments to estimate valve resistance more accurately are necessary. The existence of an optimal value of transmural pressure may provide additional guidelines for increasing pumping in areas affected by edema.
Evangelista, Charlotte; Britton, Robert J; Cucherousset, Julien
2015-06-01
Exploitation can modify the characteristics of fish populations through the selective harvesting of individuals, with this potentially leading to rapid ecological and evolutionary changes. Despite the well-known effects of invasive fishes on aquatic ecosystems generally, the potential effects of their selective removal through angling, a strategy commonly used to manage invasive fish, are poorly understood. The aim of this field-based study was to use the North American pumpkinseed Lepomis gibbosus as the model species to investigate the consequences of selective removal on their population characteristics and juvenile growth rates across 10 populations in artificial lakes in southern France. We found that the maximal individual mass in populations decreased as removal pressure through angling increased, whereas we did not observed any changes in the maximal individual length in populations as removal pressure increased. Total population abundance did not decrease as removal pressure increased; instead, here was a U-shaped relationship between removal pressure and the abundance of medium-bodied individuals. In addition, population biomass had a U-shaped curve response to removal pressure, implying that invasive fish populations can modulate their characteristics to compensate for the negative effects of selective removals. In addition, individual lengths at age 2 and juvenile growth rates decreased as removal pressure through angling increased, suggesting a shift toward an earlier size at maturity and an overall slower growing phenotype. Therefore, these outputs challenge the efficiency of selective management methods, suggesting the use of more proactive strategies to control invasive populations, and the need to investigate the potential ecological and evolutionary repercussions of nonrandom removal.
Evangelista, Charlotte; Britton, Robert J; Cucherousset, Julien
2015-01-01
Exploitation can modify the characteristics of fish populations through the selective harvesting of individuals, with this potentially leading to rapid ecological and evolutionary changes. Despite the well-known effects of invasive fishes on aquatic ecosystems generally, the potential effects of their selective removal through angling, a strategy commonly used to manage invasive fish, are poorly understood. The aim of this field-based study was to use the North American pumpkinseed Lepomis gibbosus as the model species to investigate the consequences of selective removal on their population characteristics and juvenile growth rates across 10 populations in artificial lakes in southern France. We found that the maximal individual mass in populations decreased as removal pressure through angling increased, whereas we did not observed any changes in the maximal individual length in populations as removal pressure increased. Total population abundance did not decrease as removal pressure increased; instead, here was a U-shaped relationship between removal pressure and the abundance of medium-bodied individuals. In addition, population biomass had a U-shaped curve response to removal pressure, implying that invasive fish populations can modulate their characteristics to compensate for the negative effects of selective removals. In addition, individual lengths at age 2 and juvenile growth rates decreased as removal pressure through angling increased, suggesting a shift toward an earlier size at maturity and an overall slower growing phenotype. Therefore, these outputs challenge the efficiency of selective management methods, suggesting the use of more proactive strategies to control invasive populations, and the need to investigate the potential ecological and evolutionary repercussions of nonrandom removal. PMID:26078856
Nilius, Georg; Katamadze, Nato; Domanski, Ulrike; Schroeder, Maik; Franke, Karl-Josef
2017-01-01
COPD patients who develop chronic hypercapnic respiratory failure have a poor prognosis. Treatment of choice, especially the best form of ventilation, is not well known. This study compared the effects of pressure-controlled (spontaneous timed [ST]) non-invasive ventilation (NIV) and NIV with intelligent volume-assured pressure support (IVAPS) in chronic hypercapnic COPD patients regarding the effects on alveolar ventilation, adverse patient/ventilator interactions and sleep quality. This prospective, single-center, crossover study randomized patients to one night of NIV using ST then one night with the IVAPS function activated, or vice versa. Patients were monitored using polysomnography (PSG) and transcutaneous carbon dioxide pressure (PtcCO 2 ) measurement. Patients rated their subjective experience (total score, 0-45; lower scores indicate better acceptability). Fourteen patients were included (4 females, age 59.4±8.9 years). The total number of respiratory events was low, and similar under pressure-controlled (5.4±6.7) and IVAPS (8.3±10.2) conditions ( P =0.064). There were also no clinically relevant differences in PtcCO 2 between pressure-controlled and IVAPS NIV (52.9±6.2 versus 49.1±6.4 mmHg). Respiratory rate was lower under IVAPS overall; between-group differences reached statistical significance during wakefulness and non-rapid eye movement sleep. Ventilation pressures were 2.6 cmH 2 O higher under IVAPS versus pressure-controlled ventilation, resulting in a 20.1 mL increase in breathing volume. Sleep efficiency was slightly higher under pressure-controlled ventilation versus IVAPS. Respiratory arousals were uncommon (24.4/h [pressure-controlled] versus 25.4/h [IVAPS]). Overall patient assessment scores were similar, although there was a trend toward less discomfort during IVAPS. Our results show that IVAPS NIV allows application of higher nocturnal ventilation pressures versus ST without affecting sleep quality or inducing ventilation- associated events.
Protein vs electrolytes and all of the Starling forces.
Peters, R M; Hargens, A R
1981-10-01
Hemodilution-induced reductions of the intravascular protein concentration in patients and experimental animals with intact capillaries do not lead to pulmonary edema, despite significant increases in the amount of extravascular water in the systemic interstitial space. The protective factors are a drop in the extravascular concentration of protein, a rise in interstitial tissue pressure, and an increase in lymph flow. If the capillary endothelium is damaged, protein leaks into the extravascular space, and protein infusion has a diminished effect on fluid exchange across the capillary. Whether capillaries are intact or injured, prevention of increases in capillary hydrostatic pressure is the most important factor in preventing pulmonary edema. Administration of hypertonic fluids may provide a useful method of limiting total fluid infusion and reducing cell swelling after blood loss.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luo, Di-xian, E-mail: luodixian_2@163.com; Institute of Pharmacy and Pharmacology, College of Science and Technology, University of South China, Hengyang 421001, Hunan; First People's Hospital of Chenzhou City, Chenzhou 423000, Hunan
Research highlights: {yields} Vertical static pressure accelerates ox-LDL-induced cholesterol accumulation in cultured vascular smooth muscle cells. {yields} Static pressure induces SREBP-1 activation. {yields} Static pressure downregulates the expressions of caveolin-1 by activating SREBP-1. {yields} Static pressure also downregulates the transcription of ABCA1 by activating SREBP-1. {yields} Static pressure increases ox-LDL-induced cholesterol accumulation by SREBP-1-mediated caveolin-1 downregulation in vascular smooth muscle cells cultured in vitro. -- Abstract: Objective: To investigate the effect of static pressure on cholesterol accumulation in vascular smooth muscle cells (VSMCs) and its mechanism. Methods: Rat-derived VSMC cell line A10 treated with 50 mg/L ox-LDL and different staticmore » pressures (0, 60, 90, 120, 150, 180 mm Hg) in a custom-made pressure incubator for 48 h. Intracellular lipid droplets and lipid levels were assayed by oil red O staining and HPLC; The mRNA levels of caveolin-1 and ABCA1, the protein levels of caveolin-1 SREBP-1 and mature SREBP-1 were respectively detected by RT-PCR or western blot. ALLN, an inhibitor of SREBP metabolism, was used to elevate SREBP-1 protein level in VSMCs treated with static pressure. Results: Static pressures significantly not only increase intracellular lipid droplets in VSMCs, but also elevate cellular lipid content in a pressure-dependent manner. Intracellular free cholesterol (FC), cholesterol ester (CE), total cholesterol (TC) were respectively increased from 60.5 {+-} 2.8 mg/g, 31.8 {+-} 0.7 mg/g, 92.3 {+-} 2.1 mg/g at atmosphere pressure (ATM, 0 mm Hg) to 150.8 {+-} 9.4 mg/g, 235.9 {+-} 3.0 mg/g, 386.7 {+-} 6.4 mg/g at 180 mm Hg. At the same time, static pressures decrease the mRNA and protein levels of caveolin-1, and induce the activation and nuclear translocation of SREBP-1. ALLN increases the protein level of mature SREBP-1 and decreases caveolin-1 expression, so that cellular lipid levels were upregulated. Conclusion: Static pressures stimulate ox-LDL-induced cholesterol accumulation in cultured VSMCs through decreasing caveolin-1 expression via inducing the maturation and nuclear translocation of SREBP-1.« less
Nadeau, Kristen; Chow, Kelsey; Alam, Lyla; Lindquist, Kara; Cambell, Sarah; McFann, Kim; Klingensmith, Georgeanna; Walravens, Phillipe
2014-01-01
Background Insulin resistance increases during adolescence in those with type 1 diabetes (T1DM), complicating glycemic control and potentially increasing cardiovascular disease (CVD) risk. Metformin, typically used in type 2 diabetes (T2DM), is a possible adjunct therapy in T1DM to help improve glycemic control and insulin sensitivity. Objective We hypothesized that metformin would improve metabolic parameters in adolescents with T1DM. Design, Setting, and Participants This randomized, double-blinded, placebo-controlled trial included 74 pubertal adolescents (ages 13–20 years) with T1DM. Participants were randomized to receive either metformin or placebo for six months. HbA1c, insulin dose, waist circumference, BMI, and blood pressure were measured at baseline, 3 and 6 months, with fasting lipids measured at baseline and 6 months. Results Total daily insulin dose, BMI Z-score and waist circumference significantly decreased at 3 and 6 months compared to baseline within the metformin group, even among normal-weight participants. In placebo group, total insulin dose and systolic blood pressure increased significantly at 3 months and total insulin dose increased significantly at 6 months. No significant change was observed in HbA1c at any time point between metformin and placebo groups or within either group. Conclusions Low-dose metformin likely improves BMI as well as insulin sensitivity in T1DM adolescents, as indicated by a decrease in total daily insulin dose. The decrease in waist circumference indicates that fat distribution is also likely impacted by metformin in T1DM. Further studies with higher metformin doses and more detailed measurements are needed to confirm these results, their underlying mechanisms, and potential impact on CVD in T1DM youth. PMID:24698216
Xu, Xin; Hu, Xinli; Lu, Zhongbing; Zhang, Ping; Zhao, Lin; Wessale, Jerry L.; Bache, Robert J.; Chen, Yingjie
2008-01-01
The purine analog xanthine oxidase (XO) inhibitors (XOIs), allopurinol and oxypurinol, have been reported to protect against heart failure secondary to myocardial infarction or rapid ventricular pacing. Since these agents might influence other aspects of purine metabolism that could influence their effect, this study examined the effect of the non-purine XOI, febuxostat, on pressure overload-induced left ventricular (LV) hypertrophy and dysfunction. Transverse aortic constriction (TAC) in mice caused LV hypertrophy and dysfunction as well as increased myocardial nitrotyrosine at 8 days. TAC also caused increased phosphorylated Akt (p-AktSer473), p42/44 extracellular signal-regulated kinase (p-ErkThr202/Tyr204) and mammalian target of rapamycin (mTOR) (p-mTORSer2488). XO inhibition with febuxostat (5mg/kg/day by gavage for 8 days) beginning ~60 minutes after TAC attenuated the TAC-induced LV hypertrophy and dysfunction. Febuxostat blunted the TAC-induced increases in nitrotyrosine (indicating reduced myocardial oxidative stress), p-ErkThr202/Tyr204 and p-mTORSer2488, with no effect on total Erk or total mTOR. Febuxostat had no effect on myocardial p-AktSer473 or total Akt. The results suggest that XO inhibition with febuxostat reduced oxidative stress in the pressure overloaded LV, thereby diminishing the activation of pathways that result in pathologic hypertrophy and contractile dysfunction. PMID:18995179
NASA Technical Reports Server (NTRS)
Nelson, D. P.
1981-01-01
A graphical presentation of the aerodynamic data acquired during coannular nozzle performance wind tunnel tests is given. The graphical data consist of plots of nozzle gross thrust coefficient, fan nozzle discharge coefficient, and primary nozzle discharge coefficient. Normalized model component static pressure distributions are presented as a function of primary total pressure, fan total pressure, and ambient static pressure for selected operating conditions. In addition, the supersonic cruise configuration data include plots of nozzle efficiency and secondary-to-fan total pressure pumping characteristics. Supersonic and subsonic cruise data are given.
Effect of Loading Efficiency on the Process of Consolidation in Unsaturated Soils
NASA Astrophysics Data System (ADS)
Lo, W. C.; Lee, J. W.; Deng, J. H.; Liu, J. H.
2016-12-01
Loading efficiency is an undrained poroelastic coefficient that causes an increase in the pore pressure due to an increase in the compressive axial stress. In order to illustrate the importance of loading efficiency on the process of consolidation in unsaturated soils, we utilize two assumptions proposed by Biot (1941) and Terzaghi (1943) to formulate the initial conditions taking account of loading efficiency and without consideration of loading efficiency, respectively. In Biot's theory (1941), he suggested that water is not allowed to escape when the external loading is instantly applied on a porous medium. Accordingly, the soil texture sample is considered to be undrained, and the linearized increment of the fluid content is equal to zero. For this reason, water and air can sustain an external loading only partially at the moment it is imposed, leading to an immediate one-dimensional consolidation. On the contrary, Terzaghi (1943) posited that as the external loading is initially applied, it is entirely sustained by the pore fluid. Thus, the initial water and air pressures are equal to the stress of external loading. Numerical calculations of excess pore water pressure and total settlement were made for a soil with clay texture as an illustrative example. A comparative study shows that in the early stage of consolidation, the model of considering loading efficiency generates larger time-dependent total settlement and also has the highest value of excess pore water pressure initially. The physical cause behind this difference is that the initial conditions established from Biot's theory is much smaller, reflecting the soil skeleton to carry most of external load at the moment it is imposed. Our results indicate that, in terms of the initial conditions for water and air pressures, the loading efficiency must be taken into account in the early stage of consolidation.
Malthusian overfishing and efforts to overcome it on Kenyan coral reefs.
McClanahan, Tim R; Hicks, Christina C; Darling, Emily S
2008-09-01
This study examined trends along a gradient of fishing intensity in an artisanal coral reef fishery over a 10-year period along 75 km of Kenya's most populated coastline. As predicted by Malthusian scenarios, catch per unit effort (CPUE), mean trophic level, the functional diversity of fished taxa, and the diversity of gear declined, while total annual catch and catch variability increased along the fishing pressure gradient. The fishery was able to sustain high (approximately 16 Mg x km(-2) x yr(-1)) but variable yields at high fishing pressure due to the dominance of a few productive herbivorous fish species in the catch. The effect of two separate management strategies to overcome this Malthusian pattern was investigated: fisheries area closure and elimination of the dominant and most "competitive" gear. We found that sites within 5 km of the enforced closure showed significantly lower total catch and CPUE, but increased yield stability and trophic level of catch than predicted by regression models normalized for fishing effort. Sites that had excluded illegal beach seine use through active gear management exhibited increased total catch and CPUE. There was a strong interaction between closure and gear management, which indicates that, for closures to be effective at increasing catch, there must be simultaneous efforts at gear management around the periphery of the closures. We propose that Malthusian effects are responsible for the variation in gear and catch and that active management through reduced effort and reductions in the most competitive gear have the greatest potential to increase the functional and trophic diversity and per-person productivity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oktamuliani, Sri, E-mail: srioktamuliani@ymail.com; Su’ud, Zaki, E-mail: szaki@fi.itb.ac.id
A preliminary study designs SPINNOR (Small Power Reactor, Indonesia, No On-Site Refueling) liquid metal Pb-Bi cooled fast reactors, fuel (U, Pu)N, 150 MWth have been performed. Neutronic calculation uses SRAC which is designed cylindrical core 2D (R-Z) 90 × 135 cm, on the core fuel composed of heterogeneous with percentage difference of PuN 10, 12, 13% and the result of calculation is effective neutron multiplication 1.0488. Power density distribution of the output SRAC is generated for thermal hydraulic calculation using Delphi based on Pascal language that have been developed. The research designed a reactor that is capable of natural circulation atmore » inlet temperature 300 °C with variation of total mass flow rate. Total mass flow rate affect pressure drop and temperature outlet of the reactor core. The greater the total mass flow rate, the smaller the outlet temperature, but increase the pressure drop so that the chimney needed more higher to achieve natural circulation or condition of the system does not require a pump. Optimization of the total mass flow rate produces optimal reactor design on the total mass flow rate of 5000 kg/s with outlet temperature 524,843 °C but require a chimney of 6,69 meters.« less
The Optimization of Four-Stage Low Pressure Turbine with Outlet Guide Vane
NASA Astrophysics Data System (ADS)
Matveev, V.; Baturin, O.; Popov, G.
2018-01-01
The goal of the research was to improve efficiency of four-stage low-pressure turbine with outlet guide vane (LPT) at the design point by optimization the shape of all turbine stator vanes and the stagger angles of all rotor blades. The LPT mathematical model was created by using NUMECA FineTurbo software. Several constraints were imposed the mass flow rate through the LPT and the total pressure ratio at the design point may vary within ±0.5% from the original. Parameters of the stator blade shape and rotor blades stagger angles were obtained. This new geometry of the LPT blades produce a 0.8% increase in efficiency at the design point.
De Lazzari, Claudio; Genuini, Igino; Quatember, Bernhard; Fedele, Francesco
2014-02-01
Patients assisted with left ventricular assist device (LVAD) may require prolonged mechanical ventilatory assistance secondary to postoperative respiratory failure. The goal of this work is the study of the interdependent effects LVAD like pulsatile catheter (PUCA) pump and mechanical ventilatory support or thoracic artificial lung (TAL), by the hemodynamic point of view, using a numerical simulator of the human cardiovascular system. In the simulator, different circulatory sections are described using lumped parameter models. Lumped parameter models have been designed to describe the hydrodynamic behavior of both PUCA pump and thoracic artificial lung. Ventricular behavior atrial and septum functions were reproduced using variable elastance model. Starting from simulated pathological conditions we studied the effects produced on some hemodynamic variables by simultaneous PUCA pump, thoracic artificial lung or mechanical ventilation assistance. Thoracic artificial lung was applied in parallel or in hybrid mode. The effects of mechanical ventilation have been simulated by changing mean intrathoracic pressure value from -4 mmHg to +5 mmHg. The hemodynamic variables observed during the simulations, in different assisted conditions, were: left and right ventricular end systolic (diastolic) volume, systolic/diastolic aortic pressure, mean pulmonary arterial pressure, left and right mean atrial pressure, mean systemic venous pressure and the total blood flow. Results show that the application of PUCA (without mechanical ventilatory assistance) increases the total blood flow, reduces the left ventricular end systolic volume and increases the diastolic aortic pressure. Parallel TAL assistance increases the right ventricular end diastolic (systolic) volume reduction both when PUCA is switched "ON" and both when PUCA is switched "OFF". By switching "OFF" the PUCA pump, it seems that parallel thoracic artificial lung assistance produces a greater cardiac output (respect to hybrid TAL assistance). Results concerning PUCA and TAL interaction produced by simulations cannot be compared with "in vivo" results since they are not presented in literature. But results concerning the effects produced by LVAD and mechanical ventilation have a trend consistent with those presented in literature. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Kosek, E; Roos, E M; Ageberg, E; Nilsdotter, A
2013-09-01
To assess exercise induced analgesia (EIA) and pain sensitivity in hip and knee osteoarthritis (OA) and to study the effects of neuromuscular exercise and surgery on these parameters. The dataset consisted of knee (n = 66) and hip (n = 47) OA patients assigned for total joint replacement at Lund University Hospital undergoing pre-operative neuromuscular exercise and 43 matched controls. Sensitivity to pressure pain was assessed by pressure algometry at 10 sites. Subjects were then instructed to perform a standardized static knee extension. Pressure pain thresholds (PPTs) were assessed at the contracting quadriceps muscle (Q) and at the resting deltoid muscle (D) before and during contraction. The relative increase in PPTs during contraction was taken as a measure of localized (Q) or generalized (D) EIA. Patients were assessed at baseline, following on average 12 weeks of neuromuscular exercise and 3 months following surgery. We found a normal function of EIA in OA patients at baseline. Previous studies have reported beneficial effects of physical exercise on pain modulation in healthy subjects. However, no treatment effects on EIA were seen in OA patients despite the increase in muscle strength following neuromuscular exercise and reduced pain following surgery. Compared to controls, OA patients had increased pain sensitivity and no beneficial effects on pain sensitivity were seen following treatment. To our knowledge, this is the first study of EIA in OA patients. Despite increased pain sensitivity, OA patients had a normal function of EIA. Copyright © 2013 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Kamhawi, Hani; Huang, Wensheng; Haag, Thomas; Yim, John; Herman, Daniel; Williams, George; Gilland, James; Peterson, Peter; Hofer, Richard; Mikellides, Ioannis
2016-01-01
NASAs Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5 kW Technology Demonstration Unit-1 (TDU-1) Hall thruster has been the subject of extensive technology maturation in preparation for flight system development. Part of the technology maturation effort included experimental evaluation of the TDU-1 thruster with conducting and dielectric front pole cover materials in two different electrical configurations. A graphite front pole cover thruster configuration with the thruster body electrically tied to cathode and an alumina front pole cover thruster configuration with the thruster body floating were evaluated. Both configurations were also evaluated at different facility background pressure conditions to evaluate background pressure effects on thruster operation. Performance characterization tests found that higher thruster performance was attained with the graphite front pole cover configuration with the thruster electrically tied to cathode. A total thrust efficiency of 68 and a total specific impulse of 2,820 s was demonstrated at a discharge voltage of 600 V and a discharge power of 12.5 kW. Thruster stability regimes were characterized with respect to the thruster discharge current oscillations and with maps of the current-voltage-magnetic field (IVB). Analysis of TDU-1 discharge current waveforms found that lower normalized discharge current peak-to-peak and root mean square magnitudes were attained when the thruster was electrically floated with alumina front pole covers. Background pressure effects characterization tests indicated that the thruster performance and stability was mostly invariant to changes in the facility background pressure for vacuum chamber pressure below 110-5 Torr-Xe (for thruster flow rate above 8 mgs). Power spectral density analysis of the discharge current waveform showed that increasing the vacuum chamber background pressure resulted in a higher discharge current dominant frequency. Finally the IVB maps of the TDU-1 thruster taken at elevated magnetic fields indicated that the discharge current became more oscillatory with increased facility background pressure at lower thruster mass flow rates, where thruster operation at higher flow rates resulted in less change to the thrusters IVB characteristics.
Chance, E.; Paciorek, P. M.; Todd, M. H.; Waterfall, J. F.
1985-01-01
The cardiovascular effects of the opioid mixed agonist-antagonist, meptazinol, and the opioid antagonist, naloxone, have been evaluated in conscious rats, anaesthetized rats and anaesthetized cats following the induction of haemorrhagic shock. The mean arterial pressure of conscious rats decreased by 17-29 mmHg following a haemorrhage of 20% of blood volume. Meptazinol (17 mg kg-1, i.m.) administered after haemorrhage evoked a rapid and sustained increase in mean arterial pressure to pre-haemorrhage levels. Naloxone (10 mg kg-1, i.v.) also increased mean arterial pressure to a level significantly higher than post-haemorrhage values. Neither haemorrhage nor subsequent drug treatments evoked significant changes in the heart rates of conscious rats. In anaesthetized rats, 20% haemorrhage evoked decreases in mean arterial pressure, heart rate and cardiac output. Blood flow to the heart, skin, skeletal muscle, kidneys, spleen and liver (arterial) was decreased. Meptazinol and naloxone increased blood pressure and total peripheral resistance, but did not significantly alter heart rate or cardiac output. Hepatic arterial flow decreased further in both drug and vehicle treated groups. In addition meptazinol slightly reduced skeletal muscle flow. In anaesthetized cats 40% haemorrhage decreased mean arterial pressure by 46 +/- 3 mmHg. An intravenous infusion of either meptazinol or naloxone (cumulative 2 mg kg-1, i.v.) partially restored blood pressure. In experimental animal models of haemorrhagic shock, meptazinol has a similar cardiovascular profile to naloxone. The established analgesic activity of meptazinol may confer an advantage in some shock states. PMID:4052729
Effect of Oxygen addition on altitude blowout and relight of an experimental combustor segment
NASA Technical Reports Server (NTRS)
Norgren, C. T.; Ingebo, R. D.
1974-01-01
The effect of oxygen addition on the low pressure altitude blowout limits of an experimental combustor segment was investigated. Data were obtained for two inlet-air temperatures, two inlet-airflow rates, and a constant fuel-air ratio of 0.020 with Jet A fuel. It was shown that the pressure at blowout could be reduced to correspond to an increase in altitude of 4.6 kilometers with oxygen flow rates of 8 to 16 percent by weight of the total fuel flow.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Serra-Crespo, Pablo; Dikhtiarenko, Alla; Stavitski, Eli
Here we report a series of powder X-ray diffraction experiments performed on the soft porous crystals MIL-53(Al) and NH 2-MIL-53(Al) in a diamond anvil cell under different pressurization media. Systematic refinements of the obtained powder patterns demonstrate that these materials expand along a specific direction while undergoing total volume reduction under an increasing hydrostatic pressure. Our results confirm for the first time the negative linear compressibility behaviour of this family of materials, recently predicted from quantum chemical calculations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Serra-Crespo, Pablo; Dikhtiarenko, Alla; Stavitski, Eli
Here we report a series of powder X-ray diffraction experiments performed on the soft porous crystals MIL-53(Al) and NH 2-MIL-53(Al) in a diamond anvil cell under different pressurization media. Systematic refinements of the obtained powder patterns demonstrate that these materials expand along a specific direction while undergoing total volume reduction under an increasing hydrostatic pressure. The results confirm for the first time the negative linear compressibility behaviour of this family of materials, recently predicted from quantum chemical calculations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Serra-Crespo, Pablo; Dikhtiarenko, Alla; Stavitski, Eli
Here, we report a series of powder X-ray diffraction experiments performed on the soft porous crystals MIL-53(Al) and NH 2-MIL-53(Al) in a diamond anvil cell under different pressurization media. Systematic refinements of the obtained powder patterns demonstrate that these materials expand along a specific direction while undergoing total volume reduction under an increasing hydrostatic pressure. Our results confirm for the first time the negative linear compressibility behaviour of this family of materials, recently predicted from quantum chemical calculations.
Serra-Crespo, Pablo; Dikhtiarenko, Alla; Stavitski, Eli; ...
2014-03-24
Here we report a series of powder X-ray diffraction experiments performed on the soft porous crystals MIL-53(Al) and NH 2-MIL-53(Al) in a diamond anvil cell under different pressurization media. Systematic refinements of the obtained powder patterns demonstrate that these materials expand along a specific direction while undergoing total volume reduction under an increasing hydrostatic pressure. The results confirm for the first time the negative linear compressibility behaviour of this family of materials, recently predicted from quantum chemical calculations.
Enduring medial perforant path short-term synaptic depression at high pressure.
Talpalar, Adolfo E; Giugliano, Michele; Grossman, Yoram
2010-01-01
The high pressure neurological syndrome develops during deep-diving (>1.1 MPa) involving impairment of cognitive functions, alteration of synaptic transmission and increased excitability in cortico-hippocampal areas. The medial perforant path (MPP), connecting entorhinal cortex with the hippocampal formation, displays synaptic frequency-dependent-depression (FDD) under normal conditions. Synaptic FDD is essential for specific functions of various neuronal networks. We used rat cortico-hippocampal slices and computer simulations for studying the effects of pressure and its interaction with extracellular Ca(2+) ([Ca(2+)](o)) on FDD at the MPP synapses. At atmospheric pressure, high [Ca(2+)](o) (4-6 mM) saturated single MPP field EPSP (fEPSP) and increased FDD in response to short trains at 50 Hz. High pressure (HP; 10.1 MPa) depressed single fEPSPs by 50%. Increasing [Ca(2+)](o) to 4 mM at HP saturated synaptic response at a subnormal level (only 20% recovery of single fEPSPs), but generated a FDD similar to atmospheric pressure. Mathematical model analysis of the fractions of synaptic resources used by each fEPSP during trains (normalized to their maximum) and the total fraction utilized within a train indicate that HP depresses synaptic activity also by reducing synaptic resources. This data suggest that MPP synapses may be modulated, in addition to depression of single events, by reduction of synaptic resources and then may have the ability to conserve their dynamic properties under different conditions.
Enduring Medial Perforant Path Short-Term Synaptic Depression at High Pressure
Talpalar, Adolfo E.; Giugliano, Michele; Grossman, Yoram
2010-01-01
The high pressure neurological syndrome develops during deep-diving (>1.1 MPa) involving impairment of cognitive functions, alteration of synaptic transmission and increased excitability in cortico-hippocampal areas. The medial perforant path (MPP), connecting entorhinal cortex with the hippocampal formation, displays synaptic frequency-dependent-depression (FDD) under normal conditions. Synaptic FDD is essential for specific functions of various neuronal networks. We used rat cortico-hippocampal slices and computer simulations for studying the effects of pressure and its interaction with extracellular Ca2+ ([Ca2+]o) on FDD at the MPP synapses. At atmospheric pressure, high [Ca2+]o (4–6 mM) saturated single MPP field EPSP (fEPSP) and increased FDD in response to short trains at 50 Hz. High pressure (HP; 10.1 MPa) depressed single fEPSPs by 50%. Increasing [Ca2+]o to 4 mM at HP saturated synaptic response at a subnormal level (only 20% recovery of single fEPSPs), but generated a FDD similar to atmospheric pressure. Mathematical model analysis of the fractions of synaptic resources used by each fEPSP during trains (normalized to their maximum) and the total fraction utilized within a train indicate that HP depresses synaptic activity also by reducing synaptic resources. This data suggest that MPP synapses may be modulated, in addition to depression of single events, by reduction of synaptic resources and then may have the ability to conserve their dynamic properties under different conditions. PMID:21048901
A study of pressure losses in residential air distribution systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abushakra, Bass; Walker, Iain S.; Sherman, Max H.
2002-07-01
An experimental study was conducted to evaluate the pressure drop characteristics of residential duct system components that are either not available or not thoroughly (sometimes incorrectly) described in existing duct design literature. The tests were designed to imitate cases normally found in typical residential and light commercial installations. The study included three different sizes of flexible ducts, under different compression configurations, splitter boxes, supply boots, and a fresh air intake hood. The experimental tests conformed to ASHRAE Standard 120P--''Methods of Testing to Determine Flow Resistance of HVAC Air Ducts and Fittings''. The flexible duct study covered compressibility and bending effectsmore » on the total pressure drop, and the results showed that the available published references tend to underestimate the effects of compression in flexible ducts that can increase pressure drops by up to a factor of nine. The supply boots were tested under different configurations including a setup where a flexible duct elbow connection was considered as an integral part of the supply boot. The supply boots results showed that diffusers can increase the pressure drop by up to a factor of two in exit fittings, and the installation configuration can increase the pressure drop by up to a factor of five. The results showed that it is crucial for designers and contractors to be aware of the compressibility effects of the flexible duct, and the installation of supply boots and diffusers.« less
Performance of high-area-ratio annular dump diffuser using suction-stabilized-vortex flow control
NASA Technical Reports Server (NTRS)
Juhasz, A. J.; Smith, J. M.
1977-01-01
A short annular dump diffuser having a geometry conductive to formation of suction stabilized toroidal vortices in the region of abrupt area change was tested. The overall diffuser area ratio was 4.0 and the length to inlet height ratio was 2.0. Performance data were obtained at near ambient temperature and pressure for inlet Mach numbers of 0.18 and 0.30 with suction rates ranging from 0 to 18 percent of total inlet mass flowrate. Results show that the exit velocity profile could be readily biased toward either wall by adjustment of inner and outer wall suction rates. Symmetric exit velocity profiles were inherently unstable with a tendency to revert to a hub or tip bias. Diffuser effectiveness was increased from about 38 percent without suction to over 85 percent at a total suction rate of 10 to 12 percent. At the same time diffuser total pressure loss was reduced from 3.1 percent to 1.1 percent at an inlet Mach number of 0.3.
Bright, A N; Yoshida, K; Tanaka, N
2013-01-01
Environmental transmission electron microscopy (ETEM) enables the study of catalytic and other reaction processes as they occur with Angstrom-level resolution. The microscope used is a dedicated ETEM (Titan ETEM, FEI Company) with a differential pumping vacuum system and apertures, allowing aberration corrected high-resolution transmission electron microscopy (HRTEM) imaging to be performed with gas pressures up to 20 mbar in the sample area and with significant advantages over membrane-type E-cell holders. The effect on image resolution of varying the nitrogen gas pressure, electron beam current density and total beam current were measured using information limit (Young's fringes) on a standard cross grating sample and from silicon crystal lattice imaging. As expected, increasing gas pressure causes a decrease in HRTEM image resolution. However, the total electron beam current also causes big changes in the image resolution (lower beam current giving better resolution), whereas varying the beam current density has almost no effect on resolution, a result that has not been reported previously. This behavior is seen even with zero-loss filtered imaging, which we believe shows that the drop in resolution is caused by elastic scattering at gas ions created by the incident electron beam. Suitable conditions for acquiring high resolution images in a gas environment are discussed. Lattice images at nitrogen pressures up to 16 mbar are shown, with 0.12 nm information transfer at 4 mbar. Copyright © 2012 Elsevier B.V. All rights reserved.
Ducros, Laurent; Vicaut, Eric; Soleil, Christian; Le Guen, Morgan; Gueye, Papa; Poussant, Thomas; Mebazaa, Alexandre; Payen, Didier; Plaisance, Patrick
2011-11-01
Infusion of a vasopressor during cardiopulmonary resuscitation (CPR) in humans increases end decompression (diastolic) arterial blood pressure, and consequently increases vital organ perfusion pressure and survival. Several vasoactive drugs have been tested alone or in combination, but their hemodynamic effects have not been investigated clinically in humans. We tested the hypothesis that epinephrine (1 mg) co-administered with vasopressin (40 IU) ± nitroglycerin (300 μg) results in higher diastolic blood pressure than epinephrine alone. A prospective, randomized, double-blinded controlled trial in the prehospital setting. The study included 48 patients with witnessed cardiac arrest. Patients received either epinephrine alone (E alone) or epinephrine plus vasopressin (E+V) or epinephrine plus vasopressin plus nitroglycerin (E+V+N). A femoral arterial catheter was inserted for arterial pressure measurement. The primary end point was diastolic blood pressure during CPR, 15 min after the first drug administration (T = 15 min). After exclusions, a total of 44 patients were enrolled. Diastolic blood pressures (mm Hg) at T = 15 min were not statistically different between groups (median [interquartile range]: 20 [10], 15 [6], and 15 [13] for E alone, E+V, and E+V+N, respectively. The rate of return of spontaneous circulation was 63% (n = 10) in the epinephrine group, 43% (n = 6) in the epinephrine plus vasopressin group, and 36% (n = 5) in the triple therapy group (NS). Addition of vasopressin or vasopressin plus nitroglycerin to epinephrine did not increase perfusion blood pressure compared to epinephrine alone in humans in cardiac arrest, suggesting the absence of benefit in using these drug combination(s). Copyright © 2011 Elsevier Inc. All rights reserved.
Lewis, Gregory S; Conaway, William K; Wee, Hwabok; Kim, H Mike
2017-02-28
A novel technique of "anterior offsetting" of the humeral head component to address posterior instability in total shoulder arthroplasty has been proposed, and its biomechanical benefits have been previously demonstrated experimentally. The present study sought to characterize the changes in joint mechanics associated with anterior offsetting with various amounts of glenoid retroversion using cadaver specimen-specific 3-dimensional finite element models. Specimen-specific computational finite element models were developed through importing digitized locations of six musculotendinous units of the rotator cuff and deltoid muscles based off three cadaveric shoulder specimens implanted with total shoulder arthroplasty in either anatomic or anterior humeral head offset. Additional glenoid retroversion angles (0°, 10°, 20°, and 30°) other than each specimen׳s actual retroversion were modeled. Contact area, contact force, peak pressure, center of pressure, and humeral head displacement were calculated at each offset and retroversion for statistical analysis. Anterior offsetting was associated with significant anterior shift of center of pressure and humeral head displacement upon muscle loading (p<0.05). Although statistically insignificant, anterior offsetting was associated with increased contact area and decreased peak pressure (p > 0.05). All study variables showed significant differences when compared between the 4 different glenoid retroversion angles (p < 0.05) except for total force (p < 0.05). The study finding suggests that the anterior offsetting technique may contribute to joint stability in posteriorly unstable shoulder arthroplasty and may reduce eccentric loading on glenoid components although the long term clinical results are yet to be investigated in future. Copyright © 2017 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sarath, Thengumpallil Sasindran; Waghe, Prashantkumar; Gupta, Priyanka
Chronic arsenic exposure has been linked to elevated blood pressure and cardiovascular diseases, while statins reduce the incidence of cardiovascular disease predominantly by their low density lipoprotein-lowering effect. Besides, statins have other beneficial effects, including antioxidant and anti-inflammatory activities. We evaluated whether atorvastatin, a widely used statin, can ameliorate arsenic-induced increase in blood pressure and alteration in lipid profile and also whether the amelioration could relate to altered NO and ROS signaling. Rats were exposed to sodium arsenite (100 ppm) through drinking water for 90 consecutive days. Atorvastatin (10 mg/kg bw, orally) was administered once daily during the last 30more » days of arsenic exposure. On the 91st day, blood was collected for lipid profile. Western blot of iNOS and eNOS protein, NO and 3-nitrotyrosine production, Nox-4 and p22Phox mRNA expression, Nox activity, ROS generation, lipid peroxidation and antioxidants were evaluated in thoracic aorta. Arsenic increased systolic, diastolic and mean arterial blood pressure, while it decreased HDL-C and increased LDL-C, total cholesterol and triglycerides in serum. Arsenic down-regulated eNOS and up-regulated iNOS protein expression and increased basal NO and 3-nitrotyrosine level. Arsenic increased aortic Nox-4 and p22Phox mRNA expression, Nox activity, ROS generation and lipid peroxidation. Further, arsenic decreased the activities of superoxide dismutase, catalase, and glutathione peroxidase and depleted aortic GSH content. Atorvastatin regularized blood pressure, improved lipid profile and attenuated arsenic-mediated redox alterations. The results demonstrate that atorvastatin has the potential to ameliorate arsenic-induced hypertension by improving lipid profile, aortic NO signaling and restoring vascular redox homeostasis. - Highlights: • Arsenic increased systolic, diastolic and mean arterial blood pressure and caused dyslipidemia. • Arsenic increased both oxidative and nitrosative stress in thoracic aorta. • Atorvastatin regularized blood pressure, improved lipid profile and restored redox homeostasis.« less
Moiety, Fady M Shawky; Azzam, Amal Z
2014-04-01
To ascertain whether uterine fundal pressure should have a role in the management of the second stage of labor and to determine its prevalence, benefits and adverse maternal-fetal outcomes. This was a prospective observational study set in a tertiary teaching and research obstetric hospital. A total of 8097 women in labor between 37 and 42 gestational weeks with a singleton cephalic presentation were enrolled. Subjects were subdivided into two groups: fundal pressure group (n=1974 women) and control group (n=6123 women). The primary outcome measure was the duration of the second stage. The secondary outcome measures were maternal outcomes (immediate or delayed) and neonatal outcomes. The prevalence of fundal pressure in our center was 24.38%. Fundal pressure maneuver significantly shortened the duration of the second stage among primiparous women, increased the risk of severe perineal laceration and admission to neonatal intensive care unit in comparison to the non-fundal group. Delayed maternal outcomes showed significant increase in dyspareunia and de novo stress urinary incontinence in the fundal pressure group. Although fundal pressure maneuver shortens the duration of the second stage of labor among primiparous women, it should not be used except when indicated, and under strict guidelines owing to its adverse maternal and fetal outcomes. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.
Reliability of Baropodometry on the Evaluation of Plantar Load Distribution: A Transversal Study.
Baumfeld, Daniel; Baumfeld, Tiago; da Rocha, Romário Lopes; Macedo, Benjamim; Raduan, Fernando; Zambelli, Roberto; Alves Silva, Thiago Alexandre; Nery, Caio
2017-01-01
Introduction . Baropodometry is used to measure the load distribution on feet during rest and walking. The aim of this study was to evaluate changes in plantar foot pressures distribution due to period of working and due to stretching exercises of the posterior muscular chain. Methods . In this transversal study, all participants were submitted to baropodometric evaluation at two different times: before and after the working period and before and after stretching the muscles of the posterior chain. Results . We analyzed a total of 54 feet of 27 participants. After the working period, there was an average increase in the forefoot pressure of 0.16 Kgf/cm 2 and an average decrease in the hindfoot pressure of 0.17 Kgf/cm 2 . After stretching the posterior muscular chain, the average increase in the forefoot pressure was 0.56 Kgf/cm 2 and the hindfoot average pressure decrease was 0.56 Kgf/cm 2 . These changes were not statistically significant. Discussion . It was reported that the strength of the Achilles tendon generates greater forefoot load transferred from the hindfoot. In our study, no significant variation in the distribution of plantar pressure was observed. It can be inferred that baropodometry was a reliable instrument to determine the plantar pressure, regardless of the tension of the posterior chain muscles.
Observations over Hurricanes from the Ozone Monitoring Instrument
NASA Technical Reports Server (NTRS)
Joiner, J.; Vasilkov, A.; Yang, K.; Bhartia, P. K.
2006-01-01
There is an apparent inconsistency between the total column ozone derived from the total ozone mapping spectrometer (TOMS) and aircraft observations within the eye region of tropical cyclones. The higher spectral resolution, coverage, and sampling of the ozone monitoring instrument (OMI) on NASA s Aura satellite as compared with TOMS allows for improved ozone retrievals by including estimates of cloud pressure derived simultaneously using the effects of rotational Raman scattering. The retrieved cloud pressures from OM1 are more appropriate than the climatological cloud-top pressures based on infrared measurements used in the TOMS and initial OM1 algorithms. We find that total ozone within the eye of hurricane Katrina is significantly overestimated when we use climatological cloud pressures. Using OMI-retrieved cloud pressures, total ozone in the eye is similar to that in the surrounding area. The corrected total ozone is in better agreement with aircraft measurements that imply relatively small or negligible amounts of stratospheric intrusion into the eye region of tropical cyclones.
Nouman, Muhammad; Leelasamran, Wipawan; Chatpun, Surapong
2017-08-01
Using a total contact orthosis (TCO) is an effective method to offload in diabetic patients with foot neuropathy. However, the redistribution of peak plantar pressure is mostly observed during level walking, which may differ from other walking activities. The aim of this study was to investigate the plantar pressure from 4 regions of the foot during different walking activities (level walking, ramp ascending, ramp descending, stair ascending, and stair descending) in neuropathic diabetic patients with and without a TCO. Sixteen neuropathic diabetic patients aged 40 to 60 years with calluses and hallux valgus were included in this study and were provided with TCOs made up of multifoam, Plastazote, and microcellular rubber. The plantar pressure and contact area with the TCO and without the TCO were recorded using the Pedar X system during different walking activities. A significant reduction of plantar pressure during different walking activities at the toes and forefoot regions was observed while walking with the TCO compared with walking without the TCO (control condition). Plantar pressure increased at the midfoot region when walking with the TCO, and no significant difference was observed at the hindfoot region between the control and TCO conditions. Furthermore, maximum contact area was observed during level walking with the TCO compared with other walking activities. The TCO significantly reduced and redistributed the peak plantar pressure from the sites where the ulceration rate is higher at the toes and forefoot compared with the other regions of the foot. Therapeutic level II, lesser quality randomized controlled trial.
Weinberg, Ido; Gona, Philimon; O’Donnell, Christopher J.; Jaff, Michael R.; Murabito, Joanne M.
2014-01-01
Background An increased inter-arm systolic blood pressure difference is an easily determined physical examination finding. The relationship between inter-arm systolic blood pressure difference and risk of future cardiovascular disease is uncertain. We described the prevalence and risk factor correlates of inter-arm systolic blood pressure difference in the Framingham Heart Study (FHS) original and offspring cohorts and examined the association between inter-arm systolic blood pressure difference and incident cardiovascular disease and all-cause mortality. Methods An increased inter-arm systolic blood pressure difference was defined as ≥10mmHg using the average of initial and repeat blood pressure measurements obtained in both arms. Participants were followed through 2010 for incident cardiovascular disease events. Multivariable Cox proportional hazards regression analyses were performed to investigate the effect of inter-arm systolic blood pressure difference on incident cardiovascular disease. Results We examined 3,390 (56.3% female) participants aged 40 years and older, free of cardiovascular disease at baseline, mean age of 61.1 years, who attended a FHS examination between 1991 and 1994 (original cohort) and from 1995 to 1998 (offspring cohort). The mean absolute inter-arm systolic blood pressure difference was 4.6 mmHg (range 0 to 78). Increased inter-arm systolic blood pressure difference was present in 317 (9.4%) participants. The median follow-up time was 13.3 years, during which time 598 participants (17.6%) experienced a first cardiovascular event including 83 (26.2%) participants with inter-arm systolic blood pressure difference ≥10 mmHg. Compared to those with normal inter-arm systolic blood pressure difference, participants with an elevated inter-arm systolic blood pressure difference were older (63.0 years vs. 60.9 years), had a greater prevalence of diabetes mellitus (13.3% vs. 7.5%,), higher systolic blood pressure (136.3 mmHg vs. 129.3 mmHg), and a higher total cholesterol level (212.1 mg/dL vs. 206.5 mg/dL). Inter-arm systolic blood pressure difference was associated with a significantly increased hazard of incident cardiovascular events in the multivariable adjusted model (hazard ratio 1.38, 95% CI, 1.09 to 1.75). For each 1-standard deviation unit increase in absolute interarm systolic blood pressure difference, the hazard ratio for incident cardiovascular events was 1.07 (CI, 1.00 to 1.14) in the fully-adjusted model. There was no such association with mortality (hazard ratio 1.02, 95% CI 0.76 to 1.38). Conclusions In this community-based cohort, an inter-arm systolic blood pressure difference is common and associated with a significant increased risk for future cardiovascular events, even when the absolute difference in arm systolic blood pressure is modest. These findings support research to expand clinical use of this simple measurement. PMID:24287007
Barba, Francisco J; Esteve, Maria J; Frigola, Ana
2010-09-22
Variations in levels of antioxidant compounds (ascorbic acid, total phenolics, and total carotenoids), total antioxidant capacity, and color changes in a vegetable (tomato, green pepper, green celery, onion, carrot, lemon, and olive oil) beverage treated by high hydrostatic pressure (HHP) were evaluated in this work. The effects of HHP treatment, four different pressures (100, 200, 300, and 400 MPa) and four treatment times for each pressure (from 120 to 540 s) were compared with those of thermal treatment (90-98 °C for 15 and 21 s). High pressure treatment retained significantly more ascorbic acid in the vegetable beverage than thermal treatment. However, no significant changes in total phenolics were observed between HHP treated and thermally processed vegetable beverage and unprocessed beverage. Color changes (a*, b*, L, chroma, h°, and ΔE) were less for pressurized beverage than thermally treated samples compared with unprocessed beverage.
NASA Technical Reports Server (NTRS)
Musgrave, M. E.; Gerth, W. A.; Scheld, H. W.; Strain, B. R.
1988-01-01
Mungbean (Phaseolus aureus Roxb.) seedlings were grown hypobarically to assess the effects of low pressure (21-24 kilopascals) on growth and mitochondrial respiration. Control seedlings grown at ambient pressure (101 kilopascals) were provided amounts of O2 equivalent to those provided experimental seedlings at reduced pressure to factor out responses to O2 concentration and to total pressure. Respiration was assayed using washed mitochondria, and was found to respond only to O2 concentration. Regardless of total pressure, seedlings grown at 2 millimoles O2 per liter had higher state 3 respiration rates and decreased percentages of alternative respiration compared to ambient (8.4 millimoles O2 per liter) controls. In contrast, seedling growth responded to total pressure but not to O2 concentration. Seedlings were significantly larger when grown under low pressure. While low O2 (2 millimoles O2 per liter) diminished growth at ambient pressure, growth at low pressure in the same oxygen concentration was enhanced. Respiratory development and growth of mungbean seedlings under low pressure is unimpaired whether oxygen or air is used as the chamber gas, and further, low pressure can improve growth under conditions of poor aeration.
Ogilvie, R I; Zborowska-Sluis, D
1995-09-01
The effect of L-arginine, 250 mg/kg over 10 min, on hemodynamics and venous function was studied in nine splenectomized dogs under light pentobarbital anesthesia before and after 17 +/- 1 days of rapid right ventricular pacing (RRVP) at 250 beats/min. Chronic RRVP induced mild congestive heart failure with increased mean circulatory filling (Pmcf), right atrial (Pra) and pulmonary capillary wedge pressures (Ppcw), and reduced cardiac output (CO). During the development of heart failure, total vascular compliance assessed from Pmcf-blood volume relationships during circulatory arrest was unchanged, but total vascular capacitance was markedly reduced, with an increase in stressed and reduction in unstressed blood volumes. At baseline but not after RRVP, L-arginine increased CO and reduced pulmonary vascular resistance. There were no significant changes in Pra, Ppcw, or total peripheral resistance. L-Arginine failed to alter total vascular compliance and capacitance or central blood volume in the baseline or failure state. These results do not support the hypothesis that increased Pmcf and reduced total vascular capacitance in the early stages of pacing-induced heart failure are caused by reduced substrate availability for or an endogenous competitive antagonist of NO synthase in venous endothelial cells.
Lim, Einly; Salamonsen, Robert Francis; Mansouri, Mahdi; Gaddum, Nicholas; Mason, David Glen; Timms, Daniel L; Stevens, Michael Charles; Fraser, John; Akmeliawati, Rini; Lovell, Nigel Hamilton
2015-02-01
The present study investigates the response of implantable rotary blood pump (IRBP)-assisted patients to exercise and head-up tilt (HUT), as well as the effect of alterations in the model parameter values on this response, using validated numerical models. Furthermore, we comparatively evaluate the performance of a number of previously proposed physiologically responsive controllers, including constant speed, constant flow pulsatility index (PI), constant average pressure difference between the aorta and the left atrium, constant average differential pump pressure, constant ratio between mean pump flow and pump flow pulsatility (ratioP I or linear Starling-like control), as well as constant left atrial pressure ( P l a ¯ ) control, with regard to their ability to increase cardiac output during exercise while maintaining circulatory stability upon HUT. Although native cardiac output increases automatically during exercise, increasing pump speed was able to further improve total cardiac output and reduce elevated filling pressures. At the same time, reduced venous return associated with upright posture was not shown to induce left ventricular (LV) suction. Although P l a ¯ control outperformed other control modes in its ability to increase cardiac output during exercise, it caused a fall in the mean arterial pressure upon HUT, which may cause postural hypotension or patient discomfort. To the contrary, maintaining constant average pressure difference between the aorta and the left atrium demonstrated superior performance in both exercise and HUT scenarios. Due to their strong dependence on the pump operating point, PI and ratioPI control performed poorly during exercise and HUT. Our simulation results also highlighted the importance of the baroreflex mechanism in determining the response of the IRBP-assisted patients to exercise and postural changes, where desensitized reflex response attenuated the percentage increase in cardiac output during exercise and substantially reduced the arterial pressure upon HUT. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Kaushik, Neelima; Nadella, Tejaswi; Rao, P Srinivasa
2015-11-01
This study was undertaken with an aim to enhance the enzyme inactivation during high pressure processing (HPP) with pH and total soluble solids (TSS) as additional hurdles. Impact of mango pulp pH (3.5, 4.0, 4.5) and TSS (15, 20, 25 °Brix) variations on the inactivation of pectin methylesterase (PME), polyphenol oxidase (PPO), and peroxidase (POD) enzymes were studied during HPP at 400 to 600 MPa pressure (P), 40 to 70 °C temperature (T), and 6- to 20-min pressure-hold time (t). The enzyme inactivation (%) was modeled using second order polynomial equations with a good fit that revealed that all the enzymes were significantly affected by HPP. Response surface and contour models predicted the kinetic behavior of mango pulp enzymes adequately as indicated by the small error between predicted and experimental data. The predicted kinetics indicated that for a fixed P and T, higher pulse pressure effect and increased isobaric inactivation rates were possible at lower levels of pH and TSS. In contrast, at a fixed pH or TSS level, an increase in P or T led to enhanced inactivation rates, irrespective of the type of enzyme. PPO and POD were found to have similar barosensitivity, whereas PME was found to be most resistant to HPP. Furthermore, simultaneous variation in pH and TSS levels of mango pulp resulted in higher enzyme inactivation at lower pH and TSS during HPP, where the effect of pH was found to be predominant than TSS within the experimental domain. Exploration of additional hurdles such as pH, TSS, and temperature for enzyme inactivation during high pressure processing of fruits is useful from industrial point of view, as these parameters play key role in preservation process design. © 2015 Institute of Food Technologists®
NASA Astrophysics Data System (ADS)
Aksenov, A. A.; Danilishin, A. M.; Dubenko, A. M.; Kozhukov, Y. V.
2017-08-01
Design modernization of the centrifugal compressor stage test bench with three dimensional impeller blades was carried out for the possibility of holding a series of experimental studies of different 3D impeller models. The studies relates to the problem of joint work of the impeller and the stationary channels of the housing when carrying out works on modernization with the aim of improving the parameters of the volumetric capacity or pressure in the presence of design constraints. The object of study is the experimental single end centrifugal compressor stage with the 3D impeller. Compressor stage consists of the 3D impeller, vaneless diffuser (VLD), outlet collector - folded side scroll and downstream pipe. The drive is a DC motor 75 kW. The increase gear (multiplier) was set between the compressor and DC motor, gear ratio is i = 9.8. To obtain the characteristics of the compressor and the flow area the following values were measured: total pressure, static pressure, direction (angles) of the stream in different cross sections. Additional pneumometric probes on the front wall of the VLD of the test bench have been installed. Total pressure probes and foster holes for the measurement of total and static pressure by the new drainage scheme. This allowed carrying out full experimental studies for two elements of centrifugal compressor stage. After the experimental tests the comprehensive information about the performance of model stage were obtained. Was measured geometric parameters and the constructed virtual model of the experimental bench flow part with the help of Creo Parametric 3.0 and ANSYS v. 16.2. Conducted CFD calculations and verification with experimental data. Identifies the steps for further experimental and virtual works.
Preliminary tests of an advanced high-temperature combustion system
NASA Technical Reports Server (NTRS)
Wear, J. D.; Trout, A. M.; Smith, J. M.; Jacobs, R. E.
1983-01-01
A combustion system has been developed to operate efficiently and with good durability at inlet pressures to 4.05 MPa (40 atm), inlet air temperatures to 900 K, and exhaust gas temperatures to 2480 K. A preliminary investigation of this system was conducted at inlet pressures to 0.94 MPa (9 atm), a nominal inlet air temperature of 560 K, and exhaust gas temperatures to 2135 K. A maximum combustion efficiency of 98.5 percent was attained at a fuel-air ratio of 0.033; the combustion efficiency decreased to about 90 percent as the fuel-air ratio was increased to 0.058. An average liner metal temperature of 915 K, 355 kelvins greater than the nominal inlet air temperature, was reached with an average exhaust gas temperature of 2090 K. The maximum local metal temperature at this condition was about 565 kelvins above the nominal inlet air temperature and decreased to 505 kelvins above with increasing combustor pressure. Tests to determine the isothermal total pressure loss of the combustor showed a liner loss of 1.1 percent and a system loss of 6.5 percent.
Compression-ignition engine performance with undoped and doped fuel oils and alcohol mixtures
NASA Technical Reports Server (NTRS)
Moore, Charles S; Foster, Hampton H
1939-01-01
Several fuel oils, doped fuel oils, and mixtures of alcohol and fuel oil were tested in a high-speed, single-cylinder, compression-ignition engine to determine power output, fuel consumption, and ignition and combustion characteristics. Fuel oils or doped fuel oils of high octane number had shorter ignition lags, lower rates of pressure rise, and gave smoother engine operation than fuel oils or doped fuel oils of low octane number. Higher engine rotative speeds and boost pressures resulted in smoother engine operation and permitted the use of fuel oils of relatively low octane number. Although the addition of a dope to a fuel oil decreased the ignition lag and the rate of pressure rise, the ensuing rate of combustion was somewhat slower than for the undoped fuel oil so that the effectiveness of combustion was practically unchanged. Alcohol used as an auxiliary fuel, either as a mixture or by separate injection, increased the rates of pressure rise and induced roughness. In general, the power output decreased as the proportion of alcohol increased and, below maximum power, varied with the heating value of the total fuel charge.
Performance Charts for a Turbojet System
NASA Technical Reports Server (NTRS)
Karp, Irving M.
1947-01-01
Convenient charts are presented for computing the thrust, fuel consumption, and other performance values of a turbojet system. These charts take into account the effects of ram pressure, compressor pressure ratio, ratio of combustion-chamber-outlet temperature to atmospheric temperature, compressor efficiency, turbine efficiency, combustion efficiency, discharge-nozzle coefficient, losses in total pressure in the inlet to the jet-propulsion unit and in the combustion chamber, and variation in specific heats with temperature. The principal performance charts show clearly the effects of the primary variables and correction charts provide the effects of the secondary variables. The performance of illustrative cases of turbojet systems is given. It is shown that maximum thrust per unit mass rate of air flow occurs at a lower compressor pressure ratio than minimum specific fuel consumption. The thrust per unit mass rate of air flow increases as the combustion-chamber discharge temperature increases. For minimum specific fuel consumption, however, an optimum combustion-chamber discharge temperature exists, which in some cases may be less than the limiting temperature imposed by the strength temperature characteristics of present materials.
Nakamura, Maria Aparecida Miyuki; Costa, Eduardo Leite Vieira; Carvalho, Carlos Roberto Ribeiro; Tucci, Mauro Roberto
2014-01-01
Objective: Discomfort and noncompliance with noninvasive ventilation (NIV) interfaces are obstacles to NIV success. Total face masks (TFMs) are considered to be a very comfortable NIV interface. However, due to their large internal volume and consequent increased CO2 rebreathing, their orifices allow proximal leaks to enhance CO2 elimination. The ventilators used in the ICU might not adequately compensate for such leakage. In this study, we attempted to determine whether ICU ventilators in NIV mode are suitable for use with a leaky TFM. Methods: This was a bench study carried out in a university research laboratory. Eight ICU ventilators equipped with NIV mode and one NIV ventilator were connected to a TFM with major leaks. All were tested at two positive end-expiratory pressure (PEEP) levels and three pressure support levels. The variables analyzed were ventilation trigger, cycling off, total leak, and pressurization. Results: Of the eight ICU ventilators tested, four did not work (autotriggering or inappropriate turning off due to misdetection of disconnection); three worked with some problems (low PEEP or high cycling delay); and one worked properly. Conclusions: The majority of the ICU ventilators tested were not suitable for NIV with a leaky TFM. PMID:25029653
NASA Astrophysics Data System (ADS)
Takeuchi, Wakana; Washizu, Tomoya; Ike, Shinichi; Nakatsuka, Osamu; Zaima, Shigeaki
2018-01-01
We have investigated the selective growth of a Ge1- x Sn x epitaxial layer on a line/space-patterned SiO2/Si substrate by metal-organic chemical vapor deposition. We examined the behavior of a Sn precursor of tributyl(vinyl)tin (TBVSn) during the growth on Si and SiO2 substrates and investigated the effect of the Sn precursor on the selective growth. The selective growth of the Ge1- x Sn x epitaxial layer was performed under various total pressures and growth temperatures of 300 and 350 °C. The selective growth of the Ge1- x Sn x epitaxial layer on the patterned Si region is achieved at a low total pressure without Ge1- x Sn x growth on the SiO2 region. In addition, we found that the Sn content in the Ge1- x Sn x epitaxial layer increases with width of the SiO2 region for a fixed Si width even with low total pressure. To control the Sn content in the selective growth of the Ge1- x Sn x epitaxial layer, it is important to suppress the decomposition and migration of Sn and Ge precursors.
NASA Technical Reports Server (NTRS)
Low, P. A.; Denq, J. C.; Opfer-Gehrking, T. L.; Dyck, P. J.; O'Brien, P. C.; Slezak, J. M.
1997-01-01
Normative data are limited on autonomic function tests, especially beyond age 60 years. We therefore evaluated these tests in a total of 557 normal subjects evenly distributed by age and gender from 10 to 83 years. Heart rate (HR) response to deep breathing fell with increasing age. Valsalva ratio varied with both age and gender. QSART (quantitative sudomotor axon-reflex test) volume was consistently greater in men (approximately double) and progressively declined with age for all three lower extremity sites but not the forearm site. Orthostatic blood pressure reduction was greater with increasing age. HR at rest was significantly higher in women, and the increment with head-up tilt fell with increasing age. For no tests did we find a regression to zero, and some tests seem to level off with increasing age, indicating that diagnosis of autonomic failure was possible to over 80 years of age.
NASA Astrophysics Data System (ADS)
Erum, Nazia; Iqbal, Muhammad Azhar
2017-11-01
The structural, electronic, elastic, optical and thermodynamic properties of cubic fluoroperovskite SrLiF3 at ambient and high-pressure are investigated by using first-principles total energy calculations within the framework of Generalized Gradient Approximation (GGA), combined with Quasi-harmonic Debye model in which the phonon effects are considered. The pressure effects are determined in the range of 0-50 GPa, in which cubic stability of SrLiF3 fluoroperovskite remains valid. The computed lattice parameters agree well with experimental and previous theoretical results. Decrease in lattice constant and bonds length is observed with the increase in pressure from 0 to 50 GPa. The effect of increase in pressure on electronic band structure calculations with GGA and GGA plus Tran-Blaha modified Becke-Johnson (TB-mBJ) potential reveals a predominant characteristic associated with widening of bandgap. The influence of pressure on elastic constants and their related mechanical parameters have been discussed in detail. All the calculated optical properties such as the complex dielectric function Ԑ(ω), optical conductivity σ(ω), energy loss function L(ω), absorption coefficient α(w), refractive index n (ω), reflectivity R (ω), and effective number of electrons neff, via sum rules shift towards the higher energies under the application of pressure. Moreover, important thermodynamic properties heat capacities (Cp and Cv), volume expansion coefficient (α), and Debye temperature (θD) are predicted successfully in the wide temperature and pressure ranges.
Autonomic control of body temperature and blood pressure: influences of female sex hormones.
Charkoudian, Nisha; Hart, Emma C J; Barnes, Jill N; Joyner, Michael J
2017-06-01
Female reproductive hormones exert important non-reproductive influences on autonomic regulation of body temperature and blood pressure. Estradiol and progesterone influence thermoregulation both centrally and peripherally, where estradiol tends to promote heat dissipation, and progesterone tends to promote heat conservation and higher body temperatures. Changes in thermoregulation over the course of the menstrual cycle and with hot flashes at menopause are mediated by hormonal influences on neural control of skin blood flow and sweating. The influence of estradiol is to promote vasodilation, which, in the skin, results in greater heat dissipation. In the context of blood pressure regulation, both central and peripheral hormonal influences are important as well. Peripherally, the vasodilator influence of estradiol contributes to the lower blood pressures and smaller risk of hypertension seen in young women compared to young men. This is in part due to a mechanism by which estradiol augments beta-adrenergic receptor mediated vasodilation, offsetting alpha-adrenergic vasoconstriction, and resulting in a weak relationship between muscle sympathetic nerve activity and total peripheral resistance, and between muscle sympathetic nerve activity and blood pressure. After menopause, with the loss of reproductive hormones, sympathetic nerve activity, peripheral resistance and blood pressure become more strongly related, and sympathetic nerve activity (which increases with age) becomes a more important contributor to the prevailing level of blood pressure. Continuing to increase our understanding of sex hormone influences on body temperature and blood pressure regulation will provide important insight for optimization of individualized health care for future generations of women.
Shock position sensor for supersonic inlets. [measuring pressure in the throat of a supersonic inlet
NASA Technical Reports Server (NTRS)
Dustin, M. O. (Inventor)
1975-01-01
Static pressure taps or ports are provided in the throat of a supersonic inlet, and signals indicative of the pressure at each of the ports is fed to respective comparators. Means are also provided for directing a signal indicative of the total throat pressure to the comparators. A periodic signal is superimposed on the total throat pressure so that the signal from the static pressure tabs is compared to a varying scan signal rather than to total throat pressure only. This type of comparison causes each comparator to provide a pulse width modulated output which may vary from 0% 'time on' to 100% 'time on'. The pulse width modulated outputs of the comparators are summed, filtered, and directed to a controller which operates a bypass valve such as a door whereby air is dumped from the inlet to prevent the shock wave from being expelled out the front.
Navier-Stokes analysis and experimental data comparison of compressible flow within ducts
NASA Technical Reports Server (NTRS)
Harloff, G. J.; Reichert, B. A.; Sirbaugh, J. R.; Wellborn, S. R.
1992-01-01
Many aircraft employ ducts with centerline curvature or changing cross-sectional shape to join the engine with inlet and exhaust components. S-ducts convey air to the engine compressor from the intake and often decelerate the flow to achieve an acceptable Mach number at the engine compressor by increasing the cross-sectional area downstream. Circular-to-rectangular transition ducts are used on aircraft with rectangular exhaust nozzles to connect the engine and nozzle. To achieve maximum engine performance, the ducts should minimize flow total pressure loss and total pressure distortion at the duct exit. Changes in the curvature of the duct centerline or the duct cross-sectional shape give rise to streamline curvature which causes cross stream pressure gradients. Secondary flows can be caused by deflection of the transverse vorticity component of the boundary layer. This vortex tilting results in counter-rotating vortices. Additionally, the adverse streamwise pressure gradient caused by increasing cross-sectional area can lead to flow separation. Vortex pairs have been observed in the exit planes of both duct types. These vortices are due to secondary flows induced by pressure gradients resulting from streamline curvature. Regions of low total pressure are produced when the vortices convect boundary layer fluid into the main flow. The purpose of the present study is to predict the measured flow field in a diffusing S-duct and a circular-to-rectangular transition duct with a full Navier-Stokes computer program, PARC3D, and to compare the numerical predictions with new detailed experimental measurements. The work was undertaken to extend previous studies and to provide additional CFD validation data needed to help model flows with strong secondary flow and boundary layer separation. The S-duct computation extends the study of Smith et al, and Harloff et al, which concluded that the computation might be improved by using a finer grid and more advanced turbulence models. The present study compares results for both the Baldwin-Lomas and k-epsilon turbulence models and is conducted with a refined grid. For the transition duct, two inlet conditions were considered, the first with straight flow and the second with swirling flow. The first case permits examination of the effects of the geometric transition on the flow field, while the second case includes the rotational flow effect characteristic of a gas turbine engine.
Plasma lipid profile in Nigerians with high--normal blood pressure.
Saidu, Hadiza; Karaye, Kamilu Musa; Okeahialam, Basil N
2014-12-18
High blood pressure levels have been associated with elevated atherogenic blood lipid fraction, but epidemiological surveys often give inconsistent results across population sub-groups. To determine the extent to which there are differences in lipid profile based on blood pressure levels, we assessed lipid profile of subjects with high-normal blood pressure and compared with those of hypertensives and optimally normal blood pressure. The study was a cross-sectional comparative study conducted at Aminu Kano Teaching Hospital, Kano, Nigeria. Fasting lipid levels were examined among randomly selected patients with optimally normal blood pressure (group 1), high-normal blood pressure (group 2) and those with hypertension (group 3). Optimal blood pressure was defined as systolic blood pressure (SBP) of <120 mmHg/or diastolic blood pressure (DBP) of <80 mmHg; and high-normal blood pressure as SBP of 130-139 mmHg and/or DBP of 85-89 mmHg. A total of 300 subjects were studied, 100 in each group. The mean age of subjects in group 1 was 27.32±8.20 years and 60% were female, while that of group 2 was 34.04±6.25 years, and 53% were female, and that for group 3 was 52.81±13.3 years and 56% were female. The mean total cholesterol (TC) for subjects in group1 (3.96±0.40 mmol/L) was significantly lower than levels in group2 (4.55±1.01 mmol/L); P=<0.001. Subjects in group 3 (5.20±1.88 mmol/L), however had statistically significant higher mean TC when compared with group 2; (P=0.03). The difference between the groups for low density lipoprotein cholesterol (LDL-C) and triglycerides (TG) followed the same pattern as that of TC, with statistically significant increasing trend across the blood pressure categories. Levels of high density lipoprotein cholesterol (HDL-C) were however similar across the three groups (group 2 versus group 1; P=0.49, group 2 versus group 3; P=0.9). Increased TC (>5.2 mmol/L) was absent in group1, but found among 11% of group2 subjects and 40% of those in group 3 (P-value for trend<0.001). Mean fasting plasma glucose (FPG) was 3.8±0.4 mmol/L, 4.7±1.1 mmol/L, 5.1±1.9 mmol/L and for subjects in groups 1, 2 and 3 respectively (p>0.05 for groups 2 Vs 1 and p<0.001 for groups 2 Vs 3). The differences in mean body mass index (BMI) between the groups followed a similar trend as that of FPG. Multivariate logistic regression analysis showed that FPG, TG and BMI were the strongest predictors of prehypertension [odds ratio (OR) 10.14, 95% CI (confidence interval) 3.63-28.33, P=0.000; OR 5.75, 95% CI 2.20-15.05, P=0.000; and OR 2.03, 95% CI 1.57-2.62, P=0.000 respectively]. The study has shown a significant increase in plasma TC, LDL-C and TG values as blood pressure levels increased from optimally normal, across high-normal to hypertensive levels. There was a similar trend for FPG and BMI, demonstrating the central role that blood pressure plays in these metabolic disorders in Nigerians. These findings are relevant in terms of both prevention and treatment of cardiovascular morbidities and mortality.
Assessing the impact of total extracorporeal circulation on hemodynamics in an ovine fetal model.
Xiao, Fei; Zhuang, Jian; Zhou, Cheng-Bin; Chen, Ji-Mei; Cen, Jian-Zheng; Xu, Gang; Wen, Shu-Sheng
2017-09-01
The present study aimed to evaluate the impact of total extracorporeal circulation on hemodynamics and placental function in an ovine fetal model. Mid-term ovine fetuses (n=6) underwent extracorporeal circulation (30 min), cardioplegic arrest (20 min) and monitoring (120 min). The ascending aorta and umbilical cords of the fetuses were occluded during the bypass and an extracorporeal membrane oxygenator was used as the oxygen source. Biventricular intracardiac pressures, echocardiographic data, blood gas levels and placental function variables were recorded, and statistical analysis was performed using the repeated-measure analysis of variance test. The data indicated that fetal heart rate and blood pressure at 30, 60, 90 and 120 min following the bypass were stable relative to pre-arrest baseline (pre-bypass) values (P>0.05). However, end diastolic pressures in the ovine right ventricles post-bypass were significantly increased at 30, 60, 90 and 120 min relative to pre-bypass pressures (P<0.05). The pulsatility index also increased at 30 min post-bypass relative to the pre-bypass score (0.91±0.06 vs. 0.61±0.14; P=0.007). The mean resistivity index at all time points post-bypass was consistent with the pre-bypass score (P>0.05), while the mean Tei index values for the left and right ventricles post-bypass were significantly higher at all time points relative to pre-bypass values (P<0.05). The pre-bypass fetal blood pH, SaO 2 , base excess and lactate values were maintained during arrest (P>0.05). Fetal hemodynamics and placental function additionally remained stable for up to 2 h upon reperfusion following total extracorporeal circulation and cardioplegic arrest. Collectively these data suggest that the reproducible ovine fetal model may be useful in the evaluation of fetal cardiac surgery.
Prerequisite for successful surgical outcome in urothelium lined seromuscular colocystoplasty.
Jung, Hyun Jin; Lee, Hyeyoung; Im, Young Jae; Lee, Yong Seung; Hong, Chang Hee; Han, Sang Won
2012-04-01
Urothelium lined seromuscular colocystoplasty is an ideal method of augmentation cystoplasty that avoids various complications caused by the use of gastrointestinal segments. We reviewed the long-term outcomes using this technique at a single institution. We retrospectively analyzed 34 patients who underwent urothelium lined seromuscular colocystoplasty between January 1996 and December 2007. A total of 33 patients, excluding 1 who had previously undergone artificial urinary sphincter implantation, were included in the study. Changes in urodynamic parameters, duration of anticholinergic use, incontinence and surgical complications were analyzed. Mean±SD age at surgery was 10.0±5.7 years (range 3.0 to 26.0) and duration of followup was 6.0±2.3 years (2.7 to 13.4). A total of 17 patients (51.5%) underwent simultaneous anti-incontinence surgery and urothelium lined seromuscular colocystoplasty. Mean bladder capacity increased by a factor of 2.96 and mean percentage of expected bladder capacity for age increased by a factor of 1.96 postoperatively. Of patients who underwent anti-incontinence surgery 4 of 10 whose abdominal leak point pressure was less than 40 cm H2O required additional surgery, whereas none whose abdominal leak point pressure was 40 to 60 cm H2O required reoperation. Two of 16 patients who did not undergo anti-incontinence surgery eventually required continence surgery. A total of 13 patients (39.4%) were able to discontinue anticholinergics at 47.3 months postoperatively. There were no bladder perforations, bowel obstructions or metabolic abnormalities. Urothelium lined seromuscular colocystoplasty can be primarily considered in patients without prior bladder mucosal injury. Constant high bladder outlet pressure to facilitate adhesion of bladder mucosa and seromuscular patch is critical for the best results. We recommend abdominal leak point pressure 60 cm H2O or less as an indication for simultaneous anti-incontinence surgery and urothelium lined seromuscular colocystoplasty. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Bouvette, C. M.; McPhee, B. R.; Opfer-Gehrking, T. L.; Low, P. A.
1996-01-01
OBJECTIVE: To evaluate the efficacy of various physical countermaneuvers in reducing orthostatic hypotension and its associated symptoms and to assess the efficacy of biofeedback training in enhancing the effectiveness of physical countermaneuvers. MATERIAL AND METHODS: In nine study subjects with neurogenic orthostatic hypotension, four training sessions on physical countermaneuvers were performed after tilt-up, three with visual feedback on the effect of physical countermaneuvers on blood pressure and other cardiovascular variables. Blood pressure change and orthostatic symptoms during tilt-up were determined, as were the changes in total peripheral resistance, stroke index, and heart rate. RESULTS: The five female and four male patients had a mean age of 53 years and a mean duration of symptoms of 4.2 years. On an orthostatic symptom scale of 0 to 10, these patients had a mean symptom score of 7.3. The increment in systolic blood pressure was better for some maneuvers (such as leg crossing and a combination) than others (such as neck flexion and abdominal contraction). Three patterns of responses to biofeedback were found. Simple maneuvers such as squatting did not improve with training; visual feedback was needed for maneuvers such as thigh contraction, and performance declined without biofeedback; the third pattern, seen in maneuvers such as leg crossing, showed continued improvement with training, even without biofeedback. A survey at 3 to 4 months after training revealed continued use of physical maneuvers (3.8 +/- 3.1 per day), increased standing time with each episode of presyncopal symptoms (8.3 +/- 5.8 minutes), and continued global symptomatic improvement. Total peripheral resistance, but not heart rate or stroke index, showed significant regression with blood pressure improvement. CONCLUSION: Physical countermaneuvers are efficacious in reducing orthostatic hypotension, can be augmented by use of biofeedback, and may significantly improve the functional outcome. The major mechanism of improvement is an increase in total peripheral resistance, presumably by reducing the vascular capacitance.
Report on ISS O2 Production, Gas Supply and Partial Pressure Management
NASA Technical Reports Server (NTRS)
Schaezler, Ryan N.; Cook, Anthony J.
2015-01-01
Oxygen is used on International Space Station (ISS) for metabolic support and denitrogenation procedures prior to Extra-Vehicular Activities. Nitrogen is used to maintain total pressure and account for losses associated with leakage and operational losses. Oxygen and nitrogen have been supplied by various visiting vehicles such as the Progress and Shuttle in addition to the on-orbit oxygen production capability. Starting in 2014, new high pressure oxygen/nitrogen tanks are available to launch on commercial cargo vehicles and will replace the high pressure gas source that Shuttle used to provide. To maintain a habitable atmosphere the oxygen and nitrogen partial pressures are controlled between upper and lower bounds. The full range of the allowable partial pressures along with the increased ISS cabin volume are utilized as a buffer allowing days to pass between oxygen production or direct addition of oxygen and nitrogen to the atmosphere from reserves. This paper summarizes the amount of gas supplied and produced from all of the sources and describes past experience of managing partial pressures along with the range of management options available to the ISS.
Pressure ulcer prevention in patients with advanced illness.
White-Chu, E Foy; Reddy, Madhuri
2013-03-01
Pressure ulcers can be challenging to prevent, particularly in patients with advanced illnesses. This review summarizes the relevant literature since 2011. Through a MEDLINE and CINAHL database search from January 1, 2011 to June 1, 2012, a total of 14 abstracts were found addressing the prevention of pressure ulcers in persons with advanced illness. Search terms included pressure ulcer, prevention, and control. Advanced illness was defined as patients transitioning from curative to supportive and palliative care. Ten original studies and four review articles specifically addressed pressure ulcer prevention. There were four articles that specifically addressed patients with advanced illness. The studies varied in quality. One systematic review, one randomized controlled trial, three prospective trials, two retrospective trials, one cost-effectiveness analysis, one quality improvement project, one comparative descriptive design, and four review articles were found. The interventions for pressure ulcer prevention were risk assessment, repositioning, surface selection, nutritional support and maintenance of skin integrity with or without incontinence. The quality of pressure ulcer prevention studies in persons with advanced illness is poor. Increased number and higher quality studies are needed to further investigate this important topic for these fragile patients.
Code of Federal Regulations, 2010 CFR
2010-07-01
... obtaining the liquid sample, along with the test method used to determine the epoxide concentration. This... pressures, the owner or operator shall determine the time when the pressure has fallen to half its total pressure by using Equation 13: ER08MY00.008 Where: Phalf1 = Half the total pressure of the epoxide for...
Sharma, Mona; Sinha, Renu; Trikha, Anjan; Ramachandran, Rashmi; Chandralekha, C
2016-08-01
Laryngeal mask airway (LMA) cuff pressure increases when the air is used for the cuff inflation during oxygen: nitrous oxide (O2:N2O) anaesthesia, which may lead to various problems. We compared the effects of different gases for ProSeal LMA™ (PLMA) cuff inflation in adult patients for various parameters. A total of 120 patients were randomly allocated to four groups, according to composition of gases used to inflate the PLMA cuff to achieve 40 cmH2 O cuff pressure, air (Group A), 50% O2 :air (Group OA), 50% O2:N2O (Group ON) and 100% O2 (Group O). Cuff pressure, cuff volume and ventilator parameters were monitored intraoperatively. Pharyngolaryngeal parameters were assessed at 1, 2 and 24 h postoperatively. Statistical analysis was performed using ANOVA, Fisher's exact test and step-wise logistic regression. Cuff pressure significantly increased at 10, 15 and 30 min in Group A, OA and O from initial pressure. Cuff pressure decreased at 5 min in Group ON (36.6 ± 3.5 cmH2 O) (P = 0.42). PLMA cuff volume increased in Group A, OA, O, but decreased in Group ON (6.16 ± 2.8 ml [P < 0.001], 4.7 ± 3.8 ml [P < 0.001], 1.4 ± 3.19 ml [P = 0.023] and - 1.7 ± 4.9 ml [P = 0.064], respectively), from basal levels. Ventilatory parameters were comparable in all four groups. There was no significant association between sore throat and cuff pressure, with odds ratio 1.002. Cuff inflation with 50% O2:N2O mixture provided more stable cuff pressure in comparison to air, O2 :air, 100% O2 during O2:N2O anaesthesia. Ventilatory parameters did not change with variation in PLMA cuff pressure. Post-operative sore throat had no correlation with cuff pressure.
Hassan, Nayera E; El Shebini, Salwa M; Ahmed, Nihad H; Selim Mostafa, Mohamed
2015-03-15
Study the association between the total caloric intake, protein, lipid, and some classes of fatty acids of the diet, and their effects on blood pressure in a sample of Egyptian obese women with and without visceral obesity. Five hundred forty-nine obese women were included in the study with mean age of 38.1 ± 11.56 years and mean Body mass index [BMI] of 36.17 ± 7.23. They enrolled in a program for losing weight. Visceral fat was determined using ultrasound. Blood pressure was measured 3 times and the mean was recorded. Twenty four hours dietary recall was reported. Thirty point four percentages of samples has visceral obesity ≥ 7cm; they were the older, showed higher values of BMI, visceral obesity and blood pressure. Significant difference was found between groups regarding mean value of BMI, visceral obesity, both systolic blood pressure SBP and diastolic blood pressure DBP and most of the daily macronutrients intake. In groups (2&3) positive significant correlation was recorded between (SBP) & (DBP) and total daily intake of total calories, carbohydrate, total fat, saturated fatty acids and cholesterol, and negative significant correlation with total daily intake of total protein, animal and vegetable protein, linolenic and linoleic fatty acids, while oleic fatty acid showed negative correlation with SBP&DBP in all groups. This study emphasizes the hypothesis that the macronutrients composition of diet influences blood pressure in different ways, in obese patients with visceral obesity.
Hassan, Nayera E.; El Shebini, Salwa M.; Ahmed, Nihad H.; Selim Mostafa, Mohamed
2015-01-01
AIM: Study the association between the total caloric intake, protein, lipid, and some classes of fatty acids of the diet, and their effects on blood pressure in a sample of Egyptian obese women with and without visceral obesity. METHODS: Five hundred forty-nine obese women were included in the study with mean age of 38.1 ± 11.56 years and mean Body mass index [BMI] of 36.17 ± 7.23. They enrolled in a program for losing weight. Visceral fat was determined using ultrasound. Blood pressure was measured 3 times and the mean was recorded. Twenty four hours dietary recall was reported. RESULTS: Thirty point four percentages of samples has visceral obesity ≥ 7cm; they were the older, showed higher values of BMI, visceral obesity and blood pressure. Significant difference was found between groups regarding mean value of BMI, visceral obesity, both systolic blood pressure SBP and diastolic blood pressure DBP and most of the daily macronutrients intake. In groups (2&3) positive significant correlation was recorded between (SBP) & (DBP) and total daily intake of total calories, carbohydrate, total fat, saturated fatty acids and cholesterol, and negative significant correlation with total daily intake of total protein, animal and vegetable protein, linolenic and linoleic fatty acids, while oleic fatty acid showed negative correlation with SBP&DBP in all groups. CONCLUSION: This study emphasizes the hypothesis that the macronutrients composition of diet influences blood pressure in different ways, in obese patients with visceral obesity. PMID:27275219
Experimental study of iron-chloride complexing in hydrothermal fluids
Fein, J.B.; Hemley, J.J.; d'Angelo, W. M.; Komninou, A.; Sverjensky, D.A.
1992-01-01
Mineral assemblage solubilities were measured in cold-seal pressure vessels as a function of pressure, temperature, and potassium chloride concentration in order to determine the nature and thermodynamic properties of iron-chloride complexes under hydrothermal conditions. The assemblage pyritepyrrhotite-magnetite was used to buffer f{hook}S2 and f{hook}O2, and K+ H+ ratios were buffered at reasonable geologic values using the assemblage potassium feldspar-muscovite (or andalusite)-quartz. The pressure-temperature ranges were 0.5-2.0 kbar and 300-600??C, and initial fluid compositions ranged from 0.01-2.0 molal KCl. With all other factors constant, the concentration of iron in solution increases with increasing temperature, with decreasing pressure, and with increasing total potassium chloride concentration. Changes in iron concentrations as a function of KCl concentration, in conjunction with charge balance, mass action, and mass balance constraints on the system, place constraints on the stoichiometry of the important iron-chloride complexes under each of the experimental conditions. Using least-squared linear regression fits to determine these slopes, the calculations yield values for the average ligand numbers that are in the range 1.2-1.9, with uncertainties ranging from ??0.1-0.6 at the several PT conditions considered. The slopes of the regressed fits to the data suggest that both FeCl+ and FeCl20 are important in the experimental fluids, with FeCl20 becoming dominant at the higher temperatures. Theoretical calculations, however, indicate that FeCl+ does not contribute significantly to the solubility. Because of the large uncertainties associated with some of the calculated average ligand numbers, we base our data analysis on the theoretical calculations. A statistical analysis is applied to the solubility data in order to determine the values and uncertainties of the dissociation constant for FeCl20 that best fit the data at each of the experimental pressures and temperatures. The calculated stability of FeCl20 increases with increasing temperature and total chloride concentration, and with decreasing pressure. The values of the dissociation constant of FeCl20that are calculated in this study are in moderately good agreement with FeCl20dissociation constants from other studies of iron-chloride complexing in supercritical fluids. Differences are likely due to different assumptions made concerning activity coefficients of aqueous species. Log kd values for full dissociation of FeCl20 at 0.5 kbar-300??C-and at 1 kbar-400, 500, and 600??C, respectively-are -3.75 ?? 0.40, -6.25 ?? 0.10, -9.19 ?? 0.44, and -13.29 ?? 0.09. ?? 1992.
NASA Technical Reports Server (NTRS)
Hwang, Kyu C.; Tiwari, Surrendra N.; Miley, Stanley J.
1995-01-01
In recent years, active research has been conducted to study the technological feasibility of supersonic laminar flow control on the wing of the High Speed Civil Transport (HSCT). For this study, the F-16XL has been chosen due to its highly swept crank wing planform that closely resembles the HSCT configurations. During flights, it is discovered that the shock wave generated from the aircraft inlet introduces disturbances on the wing where the data acquisition is conducted. The flow field about a supersonic inlet is characterized by a complex three dimensional pattern of shock waves generated by the geometrical configuration of a deflector and a cowl lip. Hence, in this study, experimental method is employed to investigate the effects of the variation of deflector configuration on the flow field, and consequently, the possibility of diverting the incoming shock-disturbances away from the test section. In the present experiments, a model composed of a simple circular tube with a triangular deflector is designed to study the deflector length and the deflector base width variation in the flow field. Experimental results indicate that the lowest external pressure ratio is observed at the junction where the deflector lip and the inlet cowl lip merge. Also, it is noted that the external pressure ratio, the internal pressure ratio, the coefficient of spillage drag, and the shock standoff distance decrease as the deflector length increases. In addition, the Redefined Total Pressure Recovery Ratio (RTPRR) increases with an increase in the deflector length. Results from the study of the effect of the deflector's base width variation on the flow field indicate that the lowest external pressure ratio is observed at the junction between the inlet cowl lip and the deflector lip. As the base width of the deflector increases, the external pressure ratio at 0 rotation increases, whereas the external pressure ratio at 180 rotation decreases. In addition, the internal pressure ratio and the coefficient of spillage drag decrease as the base width of the deflector increases. However, RTPRR and shock standoff distance increase as the base width increases. In conclusion, as deflector dimensions vary, distinctive patterns in the pressure variation around the inlet deflector are observed. With an increase in the deflector length and base width, the magnitude of shock-disturbances are weakened due to a decrease in the external pressure ratio. Also, as the deflector length and base width increase, a smaller bow shock angle is formed. Therefore, the inlet shock wave formation would be significantly altered, and consequently, shock disturbances on the wing test section can be avoided through appropriately designing the deflector.
Berthold, Justin; Dicianno, Brad E; Cooper, Rory A
2013-09-01
Ice sledge (or sled) hockey is a fast-paced sport that enables individuals with physical disabilities to play ice hockey. As the attraction to the sport continues to rise, the need for developing better equipment and installing preventative measures for injury will become increasingly important. One such injury includes skin pressure ulceration. A total of 26 subjects including active controls and those with spinal cord injury, multiple sclerosis, limb amputation and traumatic brain injury were studied using a pressure mapping device at the 2012 National Disabled Veterans Winter Sports Clinic to determine the risk for skin pressure ulceration and the impact of cushioning and knee angle positioning on seated pressure distributions. Sledge hockey athletes may be at increased risk for skin pressure ulceration based on seated pressure distribution data. This experiment failed to demonstrate a benefit for specialty cushioning in either group. Interestingly, knee angle positioning, particularly, knee extension significantly lowered the average seated pressures. When considering the risk for skin pressure ulceration, knee angle positioning is of particular clinical importance. More research is warranted, specifically targeting novel cushion and sledge designs and larger groups of individuals with sensory loss and severe spinal deformities. Implications for Rehabilitation Ice sledge (or sled) hockey is a fast-paced and growing adaptive sport played at the Paralympic level. Rehabilitation professionals should consider the potential for skin ulceration in this population of athletes. The effects of cushioning used in the sledge design warrants further investigation. Knee angle positioning; particularly, knee extension significantly lowers seated pressures and may reduce the potential for skin ulceration.
Intracompartmental pressure as a predictor of intratesticular blood flow: a rat model.
Watson, Matthew J; Bartkowski, Donald P; Nelson, Nathan C
2015-06-01
We identified an intratesticular pressure at which vascular flow would cease in a testicular compartment syndrome model, defining a critical vascular stop flow pressure. A total of 52 male Sprague Dawley® rats were used for the study. The testicle of each rat was delivered from the scrotum and size measurements were taken. An intracompartment pressure monitor needle was inserted into the testis to record basal intratesticular pressure. The monitor needle remained in the testicle for the duration of the procedure. Vascular flow within the testis was measured using a variable frequency linear ultrasound transducer with color flow and pulse wave Doppler modalities. Saline was infused through the compartment monitor in 5 mm Hg increments via a pressure infusion pump. Following each 5 mm Hg increase intratesticular vascular blood flow and velocities were recorded using color flow and pulse wave, respectively. Data collection proceeded until color flow images indicated a complete absence of flow within the testis. Using a paired t-test (p <0.0001), mean color flow stop flow pressure was 52.17 mm Hg (95% CI 49.57-54.77) and pulse wave stop flow pressure was 36.34 mm Hg (95% CI 33.90-38.77). Regression analysis of pulse wave vs color flow showed a slope of 0.6960 ± 0.09112, a y-intercept of 0.02427 ± 4.824 and an x-intercept of -0.03486. This is the first known study to characterize a stop flow pressure within the testicular parenchyma resulting from an increased intracompartmental pressure. Due to probe sensitivity limitations, color flow appears to provide the most precise mean pressure of occlusion of 52.17 mm Hg. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
de Kort, Sandra W K; Willemsen, Ruben H; van der Kaay, Danielle C M; Hokken-Koelega, Anita C S
2009-07-01
We previously reported that short, small for gestational age (SGA) children who were born preterm have a lower body fat percentage and a higher blood pressure, insulin secretion and disposition index than short SGA children born at term. Whether preterm birth also influences these parameters during GH treatment is unknown. To compare blood pressure, insulin sensitivity, beta-cell function and body composition during 4 years of GH treatment, between preterm and term short SGA children. A total of 404 prepubertal non-GH-deficient short SGA children were divided into 143 preterm (< 36 weeks) and 261 term children. Height, blood pressure (n = 404), body composition measured by dual energy X-ray absorptiometry (DXA) (n = 138) and insulin sensitivity and beta-cell function calculated from a frequent sampling intravenous glucose tolerance test (FSIGT) with tolbutamide (n = 74) or from the homeostasis model assessment of insulin resistance (HOMA-IR) (n = 204). In preterm and term children, GH treatment resulted in a similar decrease in systolic and diastolic blood pressure, body fat percentage, limb fat/total fat ratio and insulin sensitivity, and a similar increase in insulin secretion and disposition index. Lean body mass (LBM) corrected for gender and height increased in term children and did not change in preterm children. Multiple regression analysis revealed that this difference in GH effect on LBM was not associated with gestational age. The effect of GH treatment on metabolic and cardiovascular risk factors is similar in preterm and term short, SGA children.
Cornette, J; Buijs, E A B; Duvekot, J J; Herzog, E; Roos-Hesselink, J W; Rizopoulos, D; Meima, M; Steegers, E A P
2016-01-01
Nicardipine permits rapid control of blood pressure in women with severe pre-eclampsia (PE) and hypertensive crisis. Our objective was to investigate its maternal and fetal hemodynamic effects. Ten severely pre-eclamptic pregnant women who required intravenous nicardipine for severe hypertension were included in this prospective observational trial. Maternal macrocirculation was assessed by transthoracic echocardiography. Maternal microcirculatory perfusion was examined sublingually with the sidestream dark field imaging technique. Fetal hemodynamics were assessed by Doppler examinations of the uteroplacental and fetal circulations. Maternal cardiac output, total vascular resistance, mitral E/A ratio and capillary heterogeneity index, uterine artery pulsatility index and fetal cerebroplacental ratio were considered primary outcomes. Paired measurements, obtained before administration of nicardipine infusion and after stabilization of blood pressure, were compared. Administration of nicardipine significantly reduced the mean arterial blood pressure (median difference, 26 mmHg; P = 0.002) and total vascular resistance (median difference, 791 dynes × s/cm(5) ; P = 0.002) in all included women. This induced a reflex tachycardia with consequent increase in cardiac output of 1.55 L/min (P = 0.004). There were no significant changes in the other determinants of maternal or fetal hemodynamic parameters. Nicardipine effectively reduces blood pressure through selective afterload reduction that triggers an increase in cardiac output, without affecting maternal diastolic function, or microcirculatory, uteroplacental or fetal perfusion. This hemodynamic response is uniform and predictable. Fetomaternal cardiovascular profiling can be achieved by combining transthoracic echocardiography with obstetric Doppler. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Torres, Susan J.; Turner, Anne I.; Jayasinghe, Sisitha U.; Reynolds, John; Nowson, Caryl A.
2014-01-01
Background To determine the effect of adiposity in males aged 50-70 years on cardiovascular responses to acute psychological stress. Methods Lean (BMI 20-25 kg/m2) (n = 21) and overweight/obese (BMI 27-35 kg/m2) (n = 21) men aged 50-70 years were subjected to psychological stress. Systolic blood pressure, diastolic blood pressure, heart rate, total peripheral resistance, and cardiac output were measured by a Finometer during resting (60 min), stress (30 min), and recovery (90 min). Results The lean group had a significantly higher SBP stress reactivity when compared to the overweight/obese group (51.5 ± 3.7% vs. 41.0 ± 2.9% (mean ± SEM); p < 0.05). A significant effect of time was observed for systolic blood pressure, diastolic blood pressure, heart rate, total peripheral resistance, and cardiac output (p < 0.0001 for all). There were significant time × body type interactions for systolic blood pressure, diastolic blood pressure, heart rate, total peripheral resistance, and cardiac output (p < 0.05 for all). Total peripheral resistance during recovery was higher in the lean compared to the overweight/obese group (p < 0.05). In the lean group, systolic and diastolic blood pressure variability remained elevated after stress (p < 0.05) but returned to resting levels in the overweight/obese group (p > 0.05). Conclusion Moderate adiposity in men was associated with reduced systolic blood pressure % reactivity, total peripheral resistance, and blood pressure variability after psychological stress. Overweight/obese men appear to be at no greater risk of unfavorable cardiovascular responses to stress. PMID:25428119
Plantar pressure changes after long-distance walking.
Stolwijk, Niki M; Duysens, Jacques; Louwerens, Jan Willem K; Keijsers, Noël L W
2010-12-01
The popularity of long-distance walking (LDW) has increased in the last decades. However, the effects of LDW on plantar pressure distribution and foot complaints, in particular, after several days of walking, have not been studied. We obtained the plantar pressure data of 62 subjects who had no history of foot complaints and who walked a total distance of 199.8 km for men (n = 30) and 161.5 km for women (n = 32) during four consecutive days. Plantar pressure was measured each day after the finish (posttests I–IV) and compared with the baseline plantar pressure data, which was obtained 1 or 2 d before the march (pretest). Mean, peak, and pressure–time integral per pixel as well as the center of pressure (COP) trajectory of each foot per measurement day were calculated using the normalization method of Keijsers et al. A paired t-test with an adjusted P value was used to detect significant differences between pretest and posttest. Short-term adjustment to LDW resulted in a significant decreased loading on the toes accompanied with an increased loading on the metatarsal head III–V (P < 0.001). At all stages, particularly at later stages, there was significantly more heel loading (P < 0.001). Furthermore, the COP significantly displaced in the posterior direction but not in the mediolateral direction after marching. Contact time increased slightly from 638.5 +/- 24.2 to 675.4 +/- 22.5 ms (P < 0.001). The increased heel loading and decreased function of the toes found after marching indicate a change of walking pattern with less roll-off. It is argued that these changes reflect the effect of fatigue of the lower leg muscles and to avoid loading of the most vulnerable parts of the foot.
Kim, Pascal; Meyer, Urs; Schüpfer, Guido; Rukwied, Roman; Konrad, Christoph; Gerber, Helmut
2011-01-01
Epidural analgesia is an established method for pain management. The failure rate is 8% to 12% due to technical difficulties (catheter dislocation and/or disconnection; partial or total catheter occlusion) and management. The mechanical properties of the catheters, like tensile strength and flow rate, may also be affected by the analgesic solution and/or the tissue environment. We investigated the tensile strength and perfusion pressure of new (n=20), perioperatively (n=30), and postoperatively (n=73) used epidural catheters (20-gauge, polyamide, closed tip, 3 side holes; Perifix [B. Braun]). To prevent dislocation, epidural catheters were taped (n=5) or fixed by suture (n=68) to the skin. After removal, mechanical properties were assessed by a tensile-testing machine (INSTRON 4500), and perfusion pressure was measured at flow rates of 10, 20, and 40 mL/h. All catheters demonstrated a 2-step force transmission. Initially, a minimal increase of length could be observed at 15 N followed by an elongation of several cm at additional forces (7 N). Breakage occurred in the control group at 23.5±1.5 N compared with 22.4±1.6 N in perioperative and 22.4±1.7 N in postoperative catheters (P<0.05). Duration of catheter use had no effect on tensile strength, whereas perfusion pressure at clinically used flow rates (10 mL/h) increased significantly from 19±1.3 to 44±72 mm Hg during long-term (≥7 days) epidural analgesia (P<0.05, analysis of variance). Fixation by suture had no influence on tensile strength or perfusion pressure. Epidural catheter use significantly increases the perfusion pressure and decreases the tensile strength. Copyright © 2011 by American Society of Regional Anesthesia and Pain Medicine
Investigation on centrifugal impeller in an axial-radial combined compressor with inlet distortion
NASA Astrophysics Data System (ADS)
Li, Du; Yang, Ce; Zhao, Ben; Zhou, Mi; Qi, Mingxu; Zhang, Jizhong
2011-12-01
Assembling an axial rotor and a stator at centrifugal compressor upstream to build an axial-radial combined compressor could achieve high pressure ratio and efficiency by appropriate size augment. Then upstream potential flow and wake effect appear at centrifugal impeller inlet. In this paper, the axial-radial compressor is unsteadily simulated by three-dimensional Reynolds averaged Navier-Stokes equations with uniform and circumferential distorted total pressure inlet condition to investigate upstream effect on radial rotor. The results show that span-wise nonuniform total pressure distribution is generated and radial and circumferential combined distortion is formed at centrifugal rotor inlet. The upstream stator wake deflects to rotor rotation direction and decreases with blade span increases. Circumferential distortion causes different separated flow formations at different pitch positions. The tip leakage vortex is suppressed in centrifugal blade passages. Under distorted inlet condition, flow direction of centrifugal impeller leading edge upstream varies evidently near hub and shroud but varies slightly at mid-span. In addition, compressor stage inlet distortion produces remarkable effect on blade loading of centrifugal blade both along chordwise and pitchwise.
Analysis of sensory processing in preterm infants.
Cabral, Thais Invenção; da Silva, Louise Gracelli Pereira; Martinez, Cláudia Maria Simões; Tudella, Eloisa
2016-12-01
Premature birth suggests condition of biological vulnerability, predisposing to neurological injuries, requiring hospitalization in Neonatal Intensive Care Units, which, while contributing to increase the survival rates, expose infants to sensory stimuli harmful to the immature organism. To evaluate the sensory processing at 4 and 6months' corrected age. This was a descriptive cross-sectional study with a sample of 30 infants divided into an experimental group composed of preterm infants (n=15), and a control group composed of full-term infants (n=15). The infants were assessed using the Test of Sensory Functions in Infants. The preterm infants showed poor performance in the total score of the test in reactivity to tactile deep pressure and reactivity to vestibular stimulation. When groups were compared, significant differences in the total score (p=0.0113) and in the reactivity to tactile deep pressure (p<0.0001) were found. At 4 and 6months of corrected age, the preterm infants showed alterations in sensory processing. These changes were most evident in reactivity to tactile deep pressure and vestibular stimulation. Copyright © 2016. Published by Elsevier Ireland Ltd.
NASA Astrophysics Data System (ADS)
Janssen, J. F. J.; Suijker, J. L. G.; Peerenboom, K. S. C.; van Dijk, J.
2017-03-01
The mercury free lamp model previously discussed in Gnybida et al (2014 J. Phys. D: Appl. Phys. 47 125201) did not account for self-consistent diffusion and only included two molecular transitions. In this paper we apply, for the first time, a self-consistent diffusion algorithm that features (1) species/mass conservation up to machine accuracy and (2) an arbitrary mix of integral (total mass) and local (cold spot) constraints on the composition. Another advantage of this model is that the total pressure of the gas is calculated self consistently. Therefore, the usage of a predetermined pressure is no longer required. Additionally, the number of association processes has been increased from 2 to 6. The population as a function of interatomic separation determines the spectrum of the emitted continuum radiation. Previously, this population was calculated using the limit of low densities. In this work an expression is used that removes this limitation. The result of these improvements is that the agreement between the simulated and measured spectra has improved considerably.
Clinical significance of serum cortisol levels following surgery for congenital heart disease.
Teagarden, Alicia M; Mastropietro, Christopher W
2017-03-01
Use of hydrocortisone to treat refractory haemodynamic instability in patients recovering from surgery for congenital heart disease is common practice at many centres. We aimed to determine whether there is a relationship between total serum cortisol concentrations and haemodynamic response to this therapy. Material and methods We retrospectively reviewed patients <21 years who underwent cardiac surgery from 2011 to 2013, received hydrocortisone within 72 hours postoperatively, and had total serum cortisol measurements contemporaneous with its administration. Favourable responders were defined as patients in whom, at 24 hours after hydrocortisone initiation, either (1) systolic blood pressure was increased or unchanged and vasoactive-inotrope score was decreased or (2) systolic blood pressure increased by ⩾10% of baseline and vasoactive-inotrope score was unchanged. Variables were compared using t-tests or Mann-Whitney U tests as appropriate. In total, 24 patients were reviewed, with a median age of 1.4 months and range of 0.1-232 months. Among them, 14 (58%) patients responded favourably to hydrocortisone. At 24 hours, the median change in vasoactive-inotrope score was -18% in favourable responders and +31% in those who did not respond favourably, p=0.001. The mean pre-hydrocortisone total serum cortisol in favourable responders was 17.4±10.9 µg/dl compared with 46.1±44.7 µg/dl in those who did not respond favourably, p=0.03. Total serum cortisol obtained before initiation of hydrocortisone was significantly lower in patients who responded favourably to this therapy. Total serum cortisol may therefore be helpful in identifying children recovering from cardiac surgery who may or may not haemodynamically improve with hydrocortisone.
Aging worsens the effects of sleep deprivation on postural control.
Robillard, Rébecca; Prince, François; Filipini, Daniel; Carrier, Julie
2011-01-01
Falls increase with age and cause significant injuries in the elderly. This study aimed to determine whether age modulates the interactions between sleep deprivation and postural control and to evaluate how attention influences these interactions in the elderly. Fifteen young (24±2.7 y.o.) and 15 older adults (64±3.2 y.o.) stood still on a force plate after a night of sleep and after total sleep deprivation. Center of pressure range and velocity were measured with eyes open and with eyes closed while participants performed an interference task, a control task, and no cognitive task. Sleep deprivation increased the antero-posterior range of center of pressure in both age groups and center of pressure speed in older participants only. In elderly participants, the destabilizing effects of sleep deprivation were more pronounced with eyes closed. The interference task did not alter postural control beyond the destabilization induced by sleep loss in older subjects. It was concluded that sleep loss has greater destabilizing effects on postural control in older than in younger participants, and may therefore increase the risk of falls in the elderly.
Aging Worsens the Effects of Sleep Deprivation on Postural Control
Robillard, Rébecca; Prince, François; Filipini, Daniel; Carrier, Julie
2011-01-01
Falls increase with age and cause significant injuries in the elderly. This study aimed to determine whether age modulates the interactions between sleep deprivation and postural control and to evaluate how attention influences these interactions in the elderly. Fifteen young (24±2.7 y.o.) and 15 older adults (64±3.2 y.o.) stood still on a force plate after a night of sleep and after total sleep deprivation. Center of pressure range and velocity were measured with eyes open and with eyes closed while participants performed an interference task, a control task, and no cognitive task. Sleep deprivation increased the antero-posterior range of center of pressure in both age groups and center of pressure speed in older participants only. In elderly participants, the destabilizing effects of sleep deprivation were more pronounced with eyes closed. The interference task did not alter postural control beyond the destabilization induced by sleep loss in older subjects. It was concluded that sleep loss has greater destabilizing effects on postural control in older than in younger participants, and may therefore increase the risk of falls in the elderly. PMID:22163330
Chemical fractionation in the solar nebula
NASA Technical Reports Server (NTRS)
Grossman, L.
1977-01-01
The sequence of condensation of minerals from a cooling gas of solar composition has been calculated from thermodynamic data over the pressure range 0.001-0.00001 atm, assuming that complete chemical equilibrium is maintained. The results suggest that the Ca-Al-rich inclusions Allende and other carbonaceous chondrites are aggregates of the highest temperature condensates. Complete condensation of these elements is followed, 100 deg later, by the onset of the crystallization of nickel-iron, forsterite and enstatite. Transport of Ca-Al-rich refractory condensates from one part of the nebula to another before the condensation of these lower-temperature phases may have been responsible for the refractory element fractionations between the different classes of chondrites and possibly for the inferred refractory element enrichment of the Moon. The temperature gap between the condensation temperatures of nickel-iron and forsterite increases with increasing total pressure. Because pressure and temperature probably increased with decreasing heliocentric distance in the solar nebula, Mercury may have accreted from a condensate assemblage having a higher metal/silicate ratio than Venus or Earth which may, in turn, have formed from less oxidized material than Mars.
Okada, Kyle S; Lee, Youngsoo
2017-07-01
The effects of formulation and processing parameters on sodium availability in a model lipid/protein-based emulsion gel were studied for purposes of sodium reduction. Heat-set model gels were prepared with varying levels of protein, lipid, and NaCl contents and high pressure homogenization treatments. Single quantum and double quantum-filtered 23 Na NMR spectroscopy experiments were used to characterize sodium mobility, structural order around "bound" (restricted mobility) sodium, and sodium binding, which have been correlated to saltiness perception in food systems previously. Total sodium mobility was lower in gels with higher protein or fat content, and was not affected by changes in homogenization pressure. The gels with increased protein, fat, or homogenization pressure had increased structure surrounding "bound" sodium and more relative "bound" sodium due to increased interfacial protein interactions. The data obtained in this study provide information on factors affecting sodium availability, which can be applied towards sodium reduction in lipid/protein-based foods. © 2017 Institute of Food Technologists®.
Hashimoto, Tomomi; Takase, Hiroyuki; Okado, Tateo; Sugiura, Tomonori; Yamashita, Sumiyo; Kimura, Genjiro; Ohte, Nobuyuki; Dohi, Yasuaki
2016-08-01
The close association between dietary salt and hypertension is well established. However, previous studies generally assessed salt intake without adjustment for body weight. Herein, we investigated the significance of body weight-adjusted salt intake in the general population. The present cross-sectional study included 7629 participants from our yearly physical checkup program, and their salt intake was assessed using a spot urine test to estimate 24-hour urinary salt excretion. Total salt intake increased with increasing body weight. Body weight-adjusted salt intake was greater in participants with hypertension than in those without hypertension. Systolic blood pressure, estimated glomerular filtration rate, and urinary albumin were independently correlated with body weight-adjusted salt intake after adjustment for possible cardiovascular risk factors. Excessive body weight-adjusted salt intake could be related to an increase in blood pressure and hypertensive organ damage. Adjustment for body weight might therefore provide clinically important information when assessing individual salt intake. Copyright © 2016 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.
Phase transition studies of germanium to 1. 25 Mbar
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vohra, Y.K.; Brister, K.E.; Desgreniers, S.
1986-05-05
New phase transitions in Ge were observed by energy-dispersive x-ray diffraction techniques for pressures up to 125 GPa (1.25 Mbar) as follows: the ..beta..-Sn structure to the simple hexagonal (sh) phase at 75 +- 3 GPa and to the double hexagonal close-packed structure (dhcp) at 102 +- 5 GPa. These are the highest pressures for which a crystalline structure change has been directly observed in any material by x-ray diffraction. Total-energy pseudopotential calculations predict 84 +- 10 GPa for the ..beta..-Sn to sh phase transition and 105 +- 21 GPa for sh to hcp (not dhcp) transition. The role ofmore » 3d core electrons in increasing the transformation pressures in Ge, as compared to Si, is emphasized.« less
NASA Technical Reports Server (NTRS)
Sullivan, T. J.; Silverman, I.; Little, D. R.
1977-01-01
Test results at design speed show fan total pressure ratio, weight flow, and adiabatic efficiency to be 2.2, 2.9, and 1.8% lower than design goal values. The hybrid acoustic inlet (which utilizes a high throat Mach number and acoustic wall treatment for noise suppression) demonstrated total pressure recoveries of 98.9% and 98.2% at takeoff and approach. Exhaust duct pressure losses differed between the hardwall duct and treated duct with splitter by about 0.6% to 2.0% in terms of fan exit average total pressure (depending on operating condition). When the measured results were used to estimate pressure losses, a cruise sfc penalty of 0.68%, due to the acoustically treated duct, was projected.
Pressure, O2, and CO2, in aquatic Closed Ecological Systems
NASA Astrophysics Data System (ADS)
Taub, Frieda B.; McLaskey, Anna K.
2013-03-01
Pressure increased during net photosynthetic O2 production in the light and decreased during respiratory O2 uptake during the dark in aquatic Closed Ecological Systems (CESs) with small head gas volumes. Because most CO2 will be in the liquid phase as bicarbonate and carbonate anions, and CO2 is more soluble than O2, volumes of gaseous CO2 and gaseous O2 will not change in a compensatory manner, leading to the development of pressure. Pressure increases were greatest with nutrient rich medium with NaHCO3 as the carbon source. With more dilute media, pressure was greatest with NaHCO3, and less with cellulose or no-added carbon. Without adequate turbulence, pressure measurements lagged dissolved O2 concentrations by several hours and dark respiration would have been especially underestimated in our systems (250-1000 ml). With adequate turbulence (rotary shaker), pressure measurements and dissolved O2 concentrations generally agreed during lights on/off cycles, but O2 measurements provided more detail. At 20 °C, 29.9 times as much O2 will distribute into the gas phase as in the liquid, per unit volume, as a result of the limited solubility of O2 in water and according to Henry's Law. Thus even a small head gas volume can contain more O2 than a larger volume of water. When both dissolved and gaseous O2 and CO2 are summed, the changes in Total O2 and CO2 are in relatively close agreement when NaHCO3 is the carbon source. These findings disprove an assumption made in some of Taub's earlier research that aquatic CESs would remain at approximately atmospheric pressure because approximately equal molar quantities of O2 and CO2 would exchange during photosynthesis and respiration; this assumption neglected the distribution of O2 between water and gas phases. High pressures can occur when NaHCO3 is the carbon source in nutrient rich media and if head-gas volumes are small relative to the liquid volume; e.g., one "worse case" condition developed 800 mm Hg above atmospheric pressure and broke the glass container. Plastic screw cap closures are likely to leak at high pressures and should not be assumed to seal unless tested at appropriate pressures. Pressure can be reduced by having larger head-gas volumes and using less concentrated nutrient solutions. It is important that pressure changes be considered for both safety and closure, and if total O2 is used as the measure of net photosynthesis and respiration, the O2 in the gas phase must be added to the dissolved O2.
Total Recall: Using Film to Enhance Learning
ERIC Educational Resources Information Center
Clayton, Douglas N.
2012-01-01
Several scholars (e.g. Bumpus, 2005; Champoux, 1999; Mayer, 2005) and practitioners (Gallos 2007; English & Steffy, 1995; Hackley, 2007) of workplace learning have put forward the claim that the use of film (and other forms of multimedia) enhances learning. If this is the case, particularly given the increasing pressure to do more with less,…
Fuel/Air Mixing Characteristics of Strut Injections for Scramjet Combustor Applications (Postprint)
2008-08-01
regions, and drag will be increased, as suggested by Povinelli .26 Both the total pressure recovery and mixing efficiency for the forward-swept strut are...Experimental Study of Cavity-Strut Combustion in Supersonic Flow,” AIAA Paper 2007-5394, 2007. 26. Povinelli , L.A., “Aerodynamic Drag and Fuel Spreading
Fukamachi, Kiyotaka; Karimov, Jamshid H; Sunagawa, Gengo; Horvath, David J; Byram, Nicole; Kuban, Barry D; Dessoffy, Raymond; Sale, Shiva; Golding, Leonard A R; Moazami, Nader
2017-12-01
The purpose of this study was to evaluate the effects of sinusoidal pump speed modulation of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) on hemodynamics and pump flow in an awake chronic calf model. The sinusoidal pump speed modulations, performed on the day of elective sacrifice, were set at ±15 and ± 25% of mean pump speed at 80 bpm in four awake calves with a CFTAH. The systemic and pulmonary arterial pulse pressures increased to 12.0 and 12.3 mmHg (±15% modulation) and to 15.9 and 15.7 mmHg (±25% modulation), respectively. The pulsatility index and surplus hemodynamic energy significantly increased, respectively, to 1.05 and 1346 ergs/cm at ±15% speed modulation and to 1.51 and 3381 ergs/cm at ±25% speed modulation. This study showed that it is feasible to generate pressure pulsatility with pump speed modulation; the platform is suitable for evaluating the physiologic impact of pulsatility and allows determination of the best speed modulations in terms of magnitude, frequency, and profiles.
Muntlin Athlin, Åsa; Engström, Maria; Gunningberg, Lena; Bååth, Carina
2016-11-14
Hazardous healthcare settings, for example acute care, need to focus more on preventing adverse events and preventive actions across the care delivery chain (i.e pre-hospital and emergency care, and further at the hospital ward) should be more studied. Pressure ulcer prevalence is still at unreasonably high levels, causing increased healthcare costs and suffering for patients. Recent biomedical research reveals that the first signs of cell damage could arise within minutes. However, few studies have investigated optimal pressure ulcer prevention in the initial stage of the care process, e.g. in the ambulance care or at the emergency department. The aim of the study was to describe heel pressure ulcer prevalence and nursing actions in relation to pressure ulcer prevention during the care delivery chain, for older patients with neurological symptoms or reduced general condition. Another aim was to investigate early predictors for the development of heel pressure ulcer during the care delivery chain. Existing data collected from a multi-centre randomized controlled trial investigating the effect of using a heel prevention boot to reduce the incidence of heel pressure ulcer across the care delivery chain was used. Totally 183 patients participated. The settings for the study were five ambulance stations, two emergency departments and 16 wards at two hospitals in Sweden. A total of 39 individual patients (21 %) developed heel pressure ulcer at different stages across the care delivery chain. Findings revealed that 47-64 % of the patients were assessed as being at risk for developing heel pressure ulcer. Preventive action was taken. However, all patients who developed pressure ulcer during the care delivery chain did not receive adequate pressure ulcer prevention actions during their hospital stay. In the ambulance and at the emergency department, skin inspection seems to be appropriate for preventing pressure ulcer. However, carrying out risk assessment with a validated instrument is of significant importance at the ward level. This would also be an appropriate level of resource use. Context-specific actions for pressure ulcer prevention should be incorporated into the care of the patient from the very beginning of the care delivery chain. ISRCTN85296908 .
Determinants of systemic zero-flow arterial pressure.
Brunner, M J; Greene, A S; Sagawa, K; Shoukas, A A
1983-09-01
Thirteen pentobarbital-anesthetized dogs whose carotid sinuses were isolated and perfused at a constant pressure were placed on total cardiac bypass. With systemic venous pressure held at 0 mmHg (condition 1), arterial inflow was stopped for 20 s at intrasinus pressures of 50, 125, and 200 mmHg. Zero-flow arterial pressures under condition 1 were 16.2 +/- 1.3 (SE), 13.8 +/- 1.1, and 12.5 +/- 0.8 mmHg, respectively. In condition 2, the venous outflow tube was clamped at the instant of stopping the inflow, causing venous pressure to rise. The zero-flow arterial pressures were 19.7 +/- 1.3, 18.5 +/- 1.4, and 16.4 +/- 1.2 mmHg for intrasinus pressures of 50, 125, and 200 mmHg, respectively. At all levels of intrasinus pressure, the zero-flow arterial pressure in condition 2 was higher (P less than 0.005) than in condition 1. In seven dogs, at an intrasinus pressure of 125 mmHg, epinephrine increased the zero-flow arterial pressure by 3.0 mmHg, whereas hexamethonium and papaverine decreased the zero-flow arterial pressure by 2 mmHg. Reductions in the hematocrit from 52 to 11% resulted in statistically significant changes (P less than 0.01) in zero-flow arterial pressures. Thus zero-flow arterial pressure was found to be affected by changes in venous pressure, hematocrit, and vasomotor tone. The evidence does not support the literally interpreted concept of the vascular waterfall as the model for the finite arteriovenous pressure difference at zero flow.
Kartamyshev, Sergey P; Balashov, Sergey A; Melkumyants, Arthur M
2007-01-01
The effect of shear stress at the endothelium in the attenuation of the noradrenaline-induced constriction of the femoral vascular bed perfused at a constant blood flow was investigated in 16 anesthetized cats. It is known that the adrenergic vasoconstriction of the femoral vascular bed is considerably greater at a constant pressure perfusion than at a constant blood flow. This difference may depend on the ability of the endothelium to relax smooth muscle in response to an increase in wall shear stress. Since the shear stress is directly related to the blood flow and inversely related to the third power of vessel diameter, vasoconstriction at a constant blood flow increases the wall shear stress that is the stimulus for smooth muscle relaxation opposing constriction. On the other hand, at a constant perfusion pressure, vasoconstriction is accompanied by a decrease in flow rate, which prevents a wall shear stress increase. To reveal the effect of endothelial sensitivity to shear stress, we compared noradrenaline-induced changes in total and proximal arterial resistances during perfusion of the hind limb at a constant blood flow and at a constant pressure in vessels with intact and injured endothelium. We found that in the endothelium-intact bed the same concentration of noradrenaline at a constant flow caused an increase in overall vascular peripheral resistance that was half as large as at a constant perfusion pressure. This difference is mainly confined to the proximal arterial vessels (arteries and large arterioles) whose resistance at a constant flow increased only 0.19 +/- 0.03 times compared to that at a constant pressure. The removal of the endothelium only slightly increased constrictor responses at the perfusion under a constant pressure (noradrenaline-induced increases of both overall and proximal arterial resistance augmented by 12%), while the responses of the proximal vessels at a constant flow became 4.7 +/- 0.4 times greater than in the endothelium-intact bed. A selective blockage of endothelium sensitivity to shear stress using a glutaraldehyde dimer augmented the constrictor responses of the proximal vessels at a constant flow 4.6-fold (+/-0.3), but had no significant effect on the responses at a constant pressure. These results are consistent with the conclusion that the difference in constrictor responses at constant flow and pressure perfusions depends mainly on the smooth muscle relaxation caused by increased wall shear stress. Copyright (c) 2007 S. Karger AG, Basel.
Han, Weizhong; Han, Xiao; Sun, Ningling; Chen, Yunchao; Jiang, Shiliang; Li, Min
2017-08-01
High sodium intake plays an important role in the onset and exacerbation of hypertension. However, the relationships between urinary electrolytes excretion and central hemodynamics and between urinary electrolyte excretion and arterial stiffness are still the subject of debate. This study sought to clarify the associations of salt intake with central aortic pressure and arterial stiffness indicators. A total of 431 untreated hypertensive individuals were recruited into the study. Twenty-four-hour urinary samples were collected to measure the excretion of urinary electrolytes. Central hemodynamics parameters and brachial-ankle pulse wave velocity (baPWV) were measured. We evaluated the independent relationship between urinary sodium or potassium excretion and the abovementioned indices. The mean 24-h urinary sodium of all subjects was 166.6±70.0 mmol/24 h. With increases in urinary sodium excretion, central blood pressure and baPWV values markedly increased. Multiple regression analysis showed that urinary sodium was independently associated with increases in central systolic blood pressure, central diastolic blood pressure, the augmentation index, and baPWV. Significant correlations were identified between high dietary sodium and central hemodynamics and between high dietary sodium and arterial elasticity. Prospective interventional studies in hypertensive patients may be required to determine the effect of salt intake on central hemodynamics.
A field study of the ventilatory response to ambient temperature and pressure in sport diving.
Muller, F L
1995-01-01
This study reports on the relationship between minute ventilation (VE) and environmental variables of temperature (T) and pressure (P) during open water diving. The author conducted a total of 38 dives involving either a light (20 dives) or a moderate (18 dives) level of physical activity. Within each of these groups, P and T taken together accounted for about two thirds of the variance in the VE data. A very significant increase in VE was observed as T decreased (1 < T(degrees C) < 22), and the magnitude of this increase at a given pressure level was similar in the 'light' and the 'moderate' data sets. A second order observation, particularly notable at lower temperature, was the decrease in VE with increasing pressure under conditions of light work. Empirical functions of the from VE = A+B/P n[1 + exp(T - 8)/10], where A, B, and n are adjustable variables, could accommodate both data sets over the whole range of T and P. These results are the first obtained under actual diving conditions to provide evidence for interactions between P, T, and VE. Understanding the physiological mechanisms by which these interactions occur would assist in appreciation of the limitations imposed on scuba divers by the environmental conditions as they affect their ventilatory responses. PMID:8800853
Pnma-BN: Another Boron Nitride Polymorph with Interesting Physical Properties
Ma, Zhenyang; Han, Zheng; Liu, Xuhong; Yu, Xinhai; Wang, Dayun; Tian, Yi
2016-01-01
Structural, mechanical, electronic properties, and stability of boron nitride (BN) in Pnma structure were studied using first-principles calculations by Cambridge Serial Total Energy Package (CASTEP) plane-wave code, and the calculations were performed with the local density approximation and generalized gradient approximation in the form of Perdew–Burke–Ernzerhof. This BN, called Pnma-BN, contains four boron atoms and four nitrogen atoms buckled through sp3-hybridized bonds in an orthorhombic symmetry unit cell with Space group of Pnma. Pnma-BN is energetically stable, mechanically stable, and dynamically stable at ambient pressure and high pressure. The calculated Pugh ratio and Poisson’s ratio revealed that Pnma-BN is brittle, and Pnma-BN is found to turn brittle to ductile (~94 GPa) in this pressure range. It shows a higher mechanical anisotropy in Poisson’s ratio, shear modulus, Young’s modulus, and the universal elastic anisotropy index AU. Band structure calculations indicate that Pnma-BN is an insulator with indirect band gap of 7.18 eV. The most extraordinary thing is that the band gap increases first and then decreases with the increase of pressure from 0 to 60 GPa, and from 60 to 100 GPa, the band gap increases first and then decreases again. PMID:28336837
Andersson, Johan P A; Linér, Mats H; Jönsson, Henrik
2009-11-01
Many competitive breath-hold divers use 'glossopharyngeal insufflation', also called 'lung packing', to overfill their lungs above normal total lung capacity. This increases intrathoracic pressure, decreases venous return, compromises cardiac pumping, and reduces arterial blood pressure, possibly resulting in a syncope breath-hold divers call 'packing blackout'. We report a case with a breath-hold diver who inadvertently experienced a packing blackout. During the incident, an electrocardiogram (ECG) and blood pressure were recorded, and blood samples for determinations of biomarkers of cardiac muscle perturbation (creatine kinase-MB isoenzyme (CK-MB), cardiac troponin-T (TnT), and myoglobin) were collected. The ECG revealed short periods of asystole during the period of 'packing blackout', simultaneous with pronounced reductions in systolic, diastolic, and pulse pressures. Serum myoglobin concentration was elevated 40 and 150 min after the incident, whereas there were no changes in CK-MB or TnT. The ultimate cause of syncope in this diver probably was a decrease in cerebral perfusion following glossopharyngeal insufflation. The asystolic periods recorded in this diver could possibly indicate that susceptible individuals may be put at risk of a serious cardiac incident if the lungs are excessively overinflated by glossopharyngeal insufflation. This concern is further substantiated by the observed increase in serum myoglobin concentration after the event.
NASA Technical Reports Server (NTRS)
Kim, J. S.; Rao, M. V. V. S.; Cappelli, M. A.; Sharma, S. P.; Meyyappan, M.; Arnold, Jim (Technical Monitor)
2000-01-01
Absolute fluxes and energy distributions of ions in inductively coupled plasmas of Ar, CHF3/Ar, and CHF3/Ar/O2 have been measured. These plasmas were generated in a Gaseous Electronics Conference (GEC) cell modified for inductive coupling at pressures 10-50 mTorr and 100-300 W of 13.56 MHz radio frequency (RF) power in various feedgas mixtures. In pure Ar plasmas, the Ar(+) flux increases linearly with pressure as well as RF-power. Total ion flux in CHF3 mixtures decreases with increase in pressure and also CHF3 concentration. Relative ion fluxes observed in the present studies are analyzed with the help of available cross sections for electron impact ionization and charge-exchange ion-molecule reactions. Measurements of plasma potential, electron and ion number densities, electron energy distribution function, and mean electron energy have also been made in the center of the plasma with a RF compensated Langmuir probe. Plasma potential values are compared with the mean ion energies determined from the measured ion energy distributions and are consistent. Electron temperature, plasma potential, and mean ion energy vary inversely with pressure, but increase with CHF3 content in the mixture.