Sample records for total procedure time

  1. Efficiency of performing pulmonary procedures in a shared endoscopy unit: procedure time, turnaround time, delays, and procedure waiting time.

    PubMed

    Verma, Akash; Lee, Mui Yok; Wang, Chunhong; Hussein, Nurmalah B M; Selvi, Kalai; Tee, Augustine

    2014-04-01

    The purpose of this study was to assess the efficiency of performing pulmonary procedures in the endoscopy unit in a large teaching hospital. A prospective study from May 20 to July 19, 2013, was designed. The main outcome measures were procedure delays and their reasons, duration of procedural steps starting from patient's arrival to endoscopy unit, turnaround time, total case durations, and procedure wait time. A total of 65 procedures were observed. The most common procedure was BAL (61%) followed by TBLB (31%). Overall procedures for 35 (53.8%) of 65 patients were delayed by ≥ 30 minutes, 21/35 (60%) because of "spillover" of the gastrointestinal and surgical cases into the time block of pulmonary procedure. Time elapsed between end of pulmonary procedure and start of the next procedure was ≥ 30 minutes in 8/51 (16%) of cases. In 18/51 (35%) patients there was no next case in the room after completion of the pulmonary procedure. The average idle time of the room after the end of pulmonary procedure and start of next case or end of shift at 5:00 PM if no next case was 58 ± 53 minutes. In 17/51 (33%) patients the room's idle time was >60 minutes. A total of 52.3% of patients had the wait time >2 days and 11% had it ≥ 6 days, reason in 15/21 (71%) being unavailability of the slot. Most pulmonary procedures were delayed due to spillover of the gastrointestinal and surgical cases into the block time allocated to pulmonary procedures. The most common reason for difficulty encountered in scheduling the pulmonary procedure was slot unavailability. This caused increased procedure waiting time. The strategies to reduce procedure delays and turnaround times, along with improved scheduling methods, may have a favorable impact on the volume of procedures performed in the unit thereby optimizing the existing resources.

  2. Cost analysis of injection laryngoplasty performed under local anaesthesia versus general anaesthesia: an Australian perspective.

    PubMed

    Chandran, D; Woods, C M; Schar, M; Ma, N; Ooi, E H; Athanasiadis, T

    2018-02-01

    To conduct a cost analysis of injection laryngoplasty performed in the operating theatre under local anaesthesia and general anaesthesia. The retrospective study included patients who had undergone injection laryngoplasty as day cases between July 2013 and March 2016. Cost data were obtained, along with patient demographics, anaesthetic details, type of injectant, American Society of Anesthesiologists score, length of stay, total operating theatre time and surgeon procedure time. A total of 20 cases (general anaesthesia = 6, local anaesthesia = 14) were included in the cost analysis. The mean total cost under general anaesthesia (AU$2865.96 ± 756.29) was significantly higher than that under local anaesthesia (AU$1731.61 ± 290.29) (p < 0.001). The mean operating theatre time, surgeon procedure time and length of stay were all significantly lower under local anaesthesia compared to general anaesthesia. Time variables such as operating theatre time and length of stay were the most significant predictors of the total costs. Procedures performed under local anaesthesia in the operating theatre are associated with shorter operating theatre time and length of stay in the hospital, and provide significant cost savings. Further savings could be achieved if local anaesthesia procedures were performed in the office setting.

  3. Real waiting times for surgery. Proposal for an improved system for their management.

    PubMed

    Abásolo, Ignacio; Barber, Patricia; González López-Valcárcel, Beatriz; Jiménez, Octavio

    2014-01-01

    In Spain, official information on waiting times for surgery is based on the interval between the indication for surgery and its performance. We aimed to estimate total waiting times for surgical procedures, including outpatient visits and diagnostic tests prior to surgery. In addition, we propose an alternative system to manage total waiting times that reduces variability and maximum waiting times without increasing the use of health care resources. This system is illustrated by three surgical procedures: cholecystectomy, carpal tunnel release and inguinal/femoral hernia repair. Using data from two Autonomous Communities, we adjusted, through simulation, a theoretical distribution of the total waiting time assuming independence of the waiting times of each stage of the clinical procedure. We show an alternative system in which the waiting time for the second consultation is established according to the time previously waited for the first consultation. Average total waiting times for cholecystectomy, carpal tunnel release and inguinal/femoral hernia repair were 331, 355 and 137 days, respectively (official data are 83, 68 and 73 days, respectively). Using different negative correlations between waiting times for subsequent consultations would reduce maximum waiting times by between 2% and 15% and substantially reduce heterogeneity among patients, without generating higher resource use. Total waiting times are between two and five times higher than those officially published. The relationship between the waiting times at each stage of the medical procedure may be used to decrease variability and maximum waiting times. Copyright © 2013 SESPAS. Published by Elsevier Espana. All rights reserved.

  4. Comparison of 2015 Medicare relative value units for gender-specific procedures: Gynecologic and gynecologic-oncologic versus urologic CPT coding. Has time healed gender-worth?

    PubMed

    Benoit, M F; Ma, J F; Upperman, B A

    2017-02-01

    In 1992, Congress implemented a relative value unit (RVU) payment system to set reimbursement for all procedures covered by Medicare. In 1997, data supported that a significant gender bias existed in reimbursement for gynecologic compared to urologic procedures. The present study was performed to compare work and total RVU's for gender specific procedures effective January 2015 and to evaluate if time has healed the gender-based RVU worth. Using the 2015 CPT codes, we compared work and total RVU's for 50 pairs of gender specific procedures. We also evaluated 2015 procedure related provider compensation. The groups were matched so that the procedures were anatomically similar. We also compared 2015 to 1997 RVU and fee schedules. Evaluation of work RVU's for the paired procedures revealed that in 36 cases (72%), male vs female procedures had a higher wRVU and tRVU. For total fee/reimbursement, 42 (84%) male based procedures were compensated at a higher rate than the paired female procedures. On average, male specific surgeries were reimbursed at an amount that was 27.67% higher for male procedures than for female-specific surgeries. Female procedure based work RVU's have increased minimally from 1997 to 2015. Time and effort have trended towards resolution of some gender-related procedure worth discrepancies but there are still significant RVU and compensation differences that should be further reviewed and modified as surgical time and effort highly correlate. Copyright © 2016. Published by Elsevier Inc.

  5. "Knife to skin" time is a poor marker of operating room utilization and efficiency in cardiac surgery.

    PubMed

    Luthra, Suvitesh; Ramady, Omar; Monge, Mary; Fitzsimons, Michael G; Kaleta, Terry R; Sundt, Thoralf M

    2015-06-01

    Markers of operation room (OR) efficiency in cardiac surgery are focused on "knife to skin" and "start time tardiness." These do not evaluate the middle and later parts of the cardiac surgical pathway. The purpose of this analysis was to evaluate knife to skin time as an efficiency marker in cardiac surgery. We looked at knife to skin time, procedure time, and transfer times in the cardiac operational pathway for their correlation with predefined indices of operational efficiency (Index of Operation Efficiency - InOE, Surgical Index of Operational Efficiency - sInOE). A regression analysis was performed to test the goodness of fit of the regression curves estimated for InOE relative to the times on the operational pathway. The mean knife to skin time was 90.6 ± 13 minutes (23% of total OR time). The mean procedure time was 282 ± 123 minutes (71% of total OR time). Utilization efficiencies were highest for aortic valve replacement and coronary artery bypass grafting and least for complex aortic procedures. There were no significant procedure-specific or team-specific differences for standard procedures. Procedure times correlated the strongest with InOE (r = -0.98, p < 0.01). Compared to procedure times, knife to skin is not as strong an indicator of efficiency. A statistically significant linear dependence on InOE was observed with "procedure times" only. Procedure times are a better marker of OR efficiency than knife to skin in cardiac cases. Strategies to increase OR utilization and efficiency should address procedure times in addition to knife to skin times. © 2015 Wiley Periodicals, Inc.

  6. Cone-beam computed tomography fusion and navigation for real-time positron emission tomography-guided biopsies and ablations: a feasibility study.

    PubMed

    Abi-Jaoudeh, Nadine; Mielekamp, Peter; Noordhoek, Niels; Venkatesan, Aradhana M; Millo, Corina; Radaelli, Alessandro; Carelsen, Bart; Wood, Bradford J

    2012-06-01

    To describe a novel technique for multimodality positron emission tomography (PET) fusion-guided interventions that combines cone-beam computed tomography (CT) with PET/CT before the procedure. Subjects were selected among patients scheduled for a biopsy or ablation procedure. The lesions were not visible with conventional imaging methods or did not have uniform uptake on PET. Clinical success was defined by adequate histopathologic specimens for molecular profiling or diagnosis and by lack of enhancement on follow-up imaging for ablation procedures. Time to target (time elapsed between the completion of the initial cone-beam CT scan and first tissue sample or treatment), total procedure time (time from the moment the patient was on the table until the patient was off the table), and number of times the needle was repositioned were recorded. Seven patients underwent eight procedures (two ablations and six biopsies). Registration and procedures were completed successfully in all cases. Clinical success was achieved in all biopsy procedures and in one of the two ablation procedures. The needle was repositioned once in one biopsy procedure only. On average, the time to target was 38 minutes (range 13-54 min). Total procedure time was 95 minutes (range 51-240 min, which includes composite ablation). On average, fluoroscopy time was 2.5 minutes (range 1.3-6.2 min). An integrated cone-beam CT software platform can enable PET-guided biopsies and ablation procedures without the need for additional specialized hardware. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  7. Magnetic navigation system for percutaneous coronary intervention

    PubMed Central

    Qi, Zhiyong; Wu, Bangwei; Luo, Xinping; Zhu, Jun; Shi, Haiming; Jin, Bo

    2016-01-01

    Abstract Background: Magnetic navigation system (MNS) allows calculation of the vessel coordinates in real space within the patient's chest for percutaneous coronary intervention (PCI). However, its impact on the procedural parameters and clinical outcomes is still a matter of debate. To derive a more precise estimation of the relationship, a meta-analysis was performed. Methods and Results: Studies exploring the advantages of MNS were identified in English-language articles by search of Medline, Web of Science, and Cochrane Library Databases (inception to October 2015). A standardized protocol was used to extract details on study design, region origin, demographic data, lesion type, and clinical outcomes. The main outcome measures were contrast consumption, procedural success rate, contrast used for wire crossing, procedure time to cross the lesions, and the fluoroscopy time fluoroscopy time. A total of 12 clinical trials involving 2174 patients were included for analysis (902 patients in the magnetic PCI group and 1272 in the conventional PCI group). Overall, contrast consumption was decreased by 40.45 mL (95% confidence interval [CI] −70.98 to −9.92, P = 0.009) in magnetic PCI group compared with control group. In addition, magnetic PCI was associated with significantly decreasing procedural time by 2.17 minutes (95% CI −3.91 to −0.44, P = 0.01) and the total fluoroscopy time was significantly decreased by 1.43 minutes (95% CI −2.29 to −0.57, P = 0.001) in magnetic PCI group. However, procedural success rate, contrast used for wire crossing, procedure time to cross the lesions, and the fluoroscopy time to cross the lesions demonstrated that no statistically difference was observed between 2 groups. Conclusion: The present meta-analysis indicated an improvement of overall contrast consumption, total procedural time, and fluoroscopy time in magnetic PCI group. However, no significant advantages were observed associated with procedural success rate. PMID:27442645

  8. Magnetic navigation system for percutaneous coronary intervention: A meta-analysis.

    PubMed

    Qi, Zhiyong; Wu, Bangwei; Luo, Xinping; Zhu, Jun; Shi, Haiming; Jin, Bo

    2016-07-01

    Magnetic navigation system (MNS) allows calculation of the vessel coordinates in real space within the patient's chest for percutaneous coronary intervention (PCI). However, its impact on the procedural parameters and clinical outcomes is still a matter of debate. To derive a more precise estimation of the relationship, a meta-analysis was performed. Studies exploring the advantages of MNS were identified in English-language articles by search of Medline, Web of Science, and Cochrane Library Databases (inception to October 2015). A standardized protocol was used to extract details on study design, region origin, demographic data, lesion type, and clinical outcomes. The main outcome measures were contrast consumption, procedural success rate, contrast used for wire crossing, procedure time to cross the lesions, and the fluoroscopy time fluoroscopy time. A total of 12 clinical trials involving 2174 patients were included for analysis (902 patients in the magnetic PCI group and 1272 in the conventional PCI group). Overall, contrast consumption was decreased by 40.45 mL (95% confidence interval [CI] -70.98 to -9.92, P = 0.009) in magnetic PCI group compared with control group. In addition, magnetic PCI was associated with significantly decreasing procedural time by 2.17 minutes (95% CI -3.91 to -0.44, P = 0.01) and the total fluoroscopy time was significantly decreased by 1.43 minutes (95% CI -2.29 to -0.57, P = 0.001) in magnetic PCI group. However, procedural success rate, contrast used for wire crossing, procedure time to cross the lesions, and the fluoroscopy time to cross the lesions demonstrated that no statistically difference was observed between 2 groups. The present meta-analysis indicated an improvement of overall contrast consumption, total procedural time, and fluoroscopy time in magnetic PCI group. However, no significant advantages were observed associated with procedural success rate.

  9. Malpractice claims for endoscopy

    PubMed Central

    Hernandez, Lyndon V; Klyve, Dominic; Regenbogen, Scott E

    2013-01-01

    AIM: To summarize the magnitude and time trends of endoscopy-related claims and to compare total malpractice indemnity according to specialty and procedure. METHODS: We obtained data from a comprehensive database of closed claims from a trade association of professional liability insurance carriers, representing over 60% of practicing United States physicians. Total payments by procedure and year were calculated, and were adjusted for inflation (using the Consumer Price Index) to 2008 dollars. Time series analysis was performed to assess changes in the total value of claims for each type of procedure over time. RESULTS: There were 1901 endoscopy-related closed claims against all providers from 1985 to 2008. The specialties include: internal medicine (n = 766), gastroenterology (n = 562), general surgery (n = 231), general and family practice (n = 101), colorectal surgery (n = 87), other specialties (n = 132), and unknown (n = 22). Colonoscopy represented the highest frequencies of closed claims (n = 788) and the highest total indemnities ($54 093 000). In terms of mean claims payment, endoscopic retrograde cholangiopancreatography (ERCP) ranked the highest ($374  794) per claim. Internists had the highest number of total claims (n = 766) and total claim payment ($70  730  101). Only total claim payments for colonoscopy and ERCP seem to have increased over time. Indeed, there was an average increase of 15.5% per year for colonoscopy and 21.9% per year for ERCP after adjusting for inflation. CONCLUSION: There appear to be differences in malpractice coverage costs among specialties and the type of endoscopic procedure. There is also evidence for secular trend in total claim payments, with colonoscopy and ERCP costs rising yearly even after adjusting for inflation. PMID:23596540

  10. In-Office Endoscopic Laryngeal Laser Procedures: A Patient Safety Initiative.

    PubMed

    Anderson, Jennifer; Bensoussan, Yael; Townsley, Richard; Kell, Erika

    2018-05-01

    Objective To review complications of in-office endoscopic laryngeal laser procedures after implementation of standardized safety protocol. Methods A retrospective review was conducted of the first 2 years of in-office laser procedures at St Michaels Hospital after the introduction of a standardized safety protocol. The protocol included patient screening, procedure checklist with standardized reporting of processes, medications, and complications. Primary outcomes measured were complication rates of in-office laryngeal laser procedures. Secondary outcomes included hemodynamic changes, local anesthetic dose, laser settings, total laser/procedure time, and incidence of sedation. Results A total of 145 in-office KTP procedures performed on 65 patients were reviewed. In 98% of cases, the safety protocol was fully implemented. The overall complication rate was 4.8%. No major complications were encountered. Minor complications included vasovagal episodes and patient intolerance. The rate of patient intolerance resulting early termination of anticipated procedure was 13.1%. Total local anesthetic dose averaged 172.9 mg lidocaine per procedure. The mean amount of laser energy dispersed was 261.2 J, with mean total procedure time of 48.3 minutes. Sixteen percent of patients had preprocedure sedation. Vital signs were found to vary modestly. Systolic blood pressure was lower postprocedure in 13.8% and symptomatic in 4.1%. Discussion The review of our standardized safety protocol has revealed that in-office laser treatment for laryngeal pathology has extremely low complication rates with safe patient outcomes. Implications for Practice The trend of shifting procedures out of the operating room into the office/clinic setting requires new processes designed to promote patient safety.

  11. Comparison of intraductal ultrasonography-directed and cholangiography-directed endoscopic retrograde biliary drainage in patients with a biliary obstruction.

    PubMed

    Rew, Soo-Jung; Lee, Du-Hyeon; Park, Chang-Hwan; Jeon, Jin; Kim, Hyun-Soo; Choi, Sung-Kyu; Rew, Jong-Sun

    2016-09-01

    Endoscopic retrograde biliary drainage (ERBD) has become a standard procedure in patients with a biliary obstruction. Intraductal ultrasonography (IDUS) has emerged as a new tool for managing extrahepatic biliary diseases. IDUS-directed ERBD can be performed without conventional cholangiography (CC). The goal of this study was to assess the effectiveness and safety of IDUS-directed ERBD compared to CC-directed ERBD in patients with an extrahepatic biliary obstruction. A total of 210 patients who had undergone IDUS-directed ERBD (IDUS-ERBD, n = 105) and CC-directed ERBD (CC-ERBD, n = 105) between October 2013 and April 2014 were analyzed retrospectively. The primary outcome measure was the procedural success rate. Secondary outcome measures included clinical outcomes, total procedure time, radiation exposure time, and overall complication rates. The total technical success rate of ERBD was 100% (105/105) in the IDUS-ERBD and CC-ERBD groups. Mean procedure time was slightly prolonged in the IDUS-ERBD group than that in the CC-ERBD group (32.1 ± 9.9 minutes vs. 28.4 ± 11.6 minutes, p = 0.023). Mean radiation exposure time was one-third less in the IDUS-ERBD group than that in the CC-ERBD group (28.0 ± 49.3 seconds vs. 94.2 ± 57.3 seconds, p < 0.001). No significant differences in complication rates were detected between the groups. IDUS-ERBD was equally effective and safe as CC-ERBD in patients with an extrahepatic biliary obstruction. Although IDUS-ERBD increased total procedure time, it significantly decreased radiation exposure.

  12. Impact of Music in Reducing Patient Anxiety During Pediatric Ultrasound

    PubMed Central

    Kesselman, Andrew; Bergen, Michael; Stefanov, Dimitre; Goldfisher, Rachelle; Amodio, John

    2016-01-01

    The use of noninvasive ultrasound examinations can potentially result in significant anxiety in the pediatric population. The purpose of this study was to assess the influence of music during pediatric ultrasound examinations to reduce anxiety measured by heart rate. A total of 44 patients were recruited; 21 controls and 23 experimental. Each participant was randomized to either music or no music (control) after parental consent was obtained. Pulse oximeters were used to monitor heart rate at 15 second intervals for a total of 1 minute, with mean values calculated prior to entering the procedure room, during the middle of the procedure, and after the procedure was completed. The total scan time was determined from the initial image acquisition until the last image recorded by the ultrasound technologist. At the completion of each procedure, the ultrasound technologist scored the ease of performance for the scan on a subjective scale of 1-10 based on prior experience. When utilizing music during pediatric ultrasounds examinations, our study demonstrated significantly decreased heart rate variability from pre-procedural to post-procedural periods. There was no statistical significant difference in total scan time or ultrasound technologist scoring between the two groups. This study demonstrates that music is an inexpensive and effective means of reducing anxiety during pediatric ultrasound as indicated by heart rate. PMID:27114817

  13. US-Guided, Direct Puncture Retrograde Thoracic Duct Access, Lymphangiography, and Embolization: Feasibility and Efficacy.

    PubMed

    Guevara, Carlos J; Rialon, Kristy L; Ramaswamy, Raja S; Kim, Seung K; Darcy, Michael D

    2016-12-01

    To describe technical details, success rate, and advantages of direct puncture of the thoracic duct (TD) under direct ultrasound (US) guidance at venous insertion in the left neck. All patients who underwent attempted thoracic duct embolization (TDE) via US-guided retrograde TD access in the left neck were retrospectively reviewed. Indications for lymphangiography were iatrogenic chyle leak, pulmonary lymphangiectasia, and plastic bronchitis. Ten patients with mean age 41.4 years (range, 21 d to 72 y) underwent US-guided TD access via the left neck. Technical details, procedural times, and clinical outcomes were evaluated. TD access time was defined as time from start of procedure to successful access of TD, and total procedural time was defined from start of procedure until TDE. All attempts at TD access via the neck were successful. Technical and clinical success of TDE was 60%. There were no complications. Mean TD access time was 17 minutes (range, 2-47 min), and mean total procedure time was 49 minutes (range, 25-69 min). Mean follow-up time was 5.4 months (range, 3-10 months). TDE via US-guided access in the left neck is technically feasible and safe with a potential decrease in procedure time and elimination of oil-based contrast material. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  14. Temporary bypass for superior vena cava reconstruction with Anthron bypass tubeTM

    PubMed Central

    Yamasaki, Naoya; Tsuchiya, Tomoshi; Miyazaki, Takuro; Kamohara, Ryotaro; Hatachi, Go; Nagayasu, Takeshi

    2017-01-01

    Total superior vena cava (SVC) clamping for SVC replacement or repair can be used in thoracic surgery. A bypass technique is an option to avoid hemodynamic instability and cerebral venous hypertension and hypoperfusion. The present report describes a venous bypass technique using Anthron bypass tubeTM for total SVC clamping. Indications for this procedure include the need for a temporary bypass between the brachiocephalic vein and atrium for complete tumor resection. This procedure allows the surgeons sufficient time to complete replacement of SVC or partial resection of SVC without adverse effects. Further, it is a relatively simple procedure requiring minimal time. PMID:28840027

  15. Surgical team turnover and operative time: An evaluation of operating room efficiency during pulmonary resection.

    PubMed

    Azzi, Alain Joe; Shah, Karan; Seely, Andrew; Villeneuve, James Patrick; Sundaresan, Sudhir R; Shamji, Farid M; Maziak, Donna E; Gilbert, Sebastien

    2016-05-01

    Health care resources are costly and should be used judiciously and efficiently. Predicting the duration of surgical procedures is key to optimizing operating room resources. Our objective was to identify factors influencing operative time, particularly surgical team turnover. We performed a single-institution, retrospective review of lobectomy operations. Univariate and multivariate analyses were performed to evaluate the impact of different factors on surgical time (skin-to-skin) and total procedure time. Staff turnover within the nursing component of the surgical team was defined as the number of instances any nurse had to leave the operating room over the total number of nurses involved in the operation. A total of 235 lobectomies were performed by 5 surgeons, most commonly for lung cancer (95%). On multivariate analysis, percent forced expiratory volume in 1 second, surgical approach, and lesion size had a significant effect on surgical time. Nursing turnover was associated with a significant increase in surgical time (53.7 minutes; 95% confidence interval, 6.4-101; P = .026) and total procedure time (83.2 minutes; 95% confidence interval, 30.1-136.2; P = .002). Active management of surgical team turnover may be an opportunity to improve operating room efficiency when the surgical team is engaged in a major pulmonary resection. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  16. The 2012 SAGE wait times program: Survey of Access to GastroEnterology in Canada

    PubMed Central

    Leddin, Desmond; Armstrong, David; Borgaonkar, Mark; Bridges, Ronald J; Fallone, Carlo A; Telford, Jennifer J; Chen, Ying; Colacino, Palma; Sinclair, Paul

    2013-01-01

    BACKGROUND: Periodically surveying wait times for specialist health services in Canada captures current data and enables comparisons with previous surveys to identify changes over time. METHODS: During one week in April 2012, Canadian gastroenterologists were asked to complete a questionnaire (online or by fax) recording demographics, reason for referral, and dates of referral and specialist visits for at least 10 consecutive new patients (five consultations and five procedures) who had not been seen previously for the same indication. Wait times were determined for 18 indications and compared with those from similar surveys conducted in 2008 and 2005. RESULTS: Data regarding adult patients were provided by 173 gastroenterologists for 1374 consultations, 540 procedures and 293 same-day consultations and procedures. Nationally, the median wait times were 92 days (95% CI 85 days to 100 days) from referral to consultation, 55 days (95% CI 50 days to 61 days) from consultation to procedure and 155 days (95% CI 142 days to 175 days) (total) from referral to procedure. Overall, wait times were longer in 2012 than in 2005 (P<0.05); the wait time to same-day consultation and procedure was shorter in 2012 than in 2008 (78 days versus 101 days; P<0.05), but continued to be longer than in 2005 (P<0.05). The total wait time remained longest for screening colonoscopy, increasing from 201 days in 2008 to 279 days in 2012 (P<0.05). DISCUSSION: Wait times for gastroenterology services continue to exceed recommended targets, remain unchanged since 2008 and exceed wait times reported in 2005. PMID:23472243

  17. A real world analysis of payment per unit time in a Maryland Vascular Practice.

    PubMed

    Martin, John D; Warble, Patricia B; Hupp, Jon A; Mapes, Jerry E; Stanziale, Stephen F; Weiss, Linda L; Schiller, Toni B; Hanson, Louise A

    2010-10-01

    In 1992, Centers for Medicare and Medicaid Services instituted the Resource Based Relative Value Scale (RBRVS) system to determine physician reimbursement. Relative value units (RVU) were assigned to each Current Procedure Terminology (CPT) code and intended to reflect the time and intensity of work. Little data exist correlating actual procedural and clinical time with respect to reimbursement within the RVU value system. The purpose of this study was to determine how well this system distributes payments per hour for hospital-based procedures in a single vascular practice in the state of Maryland between July 1, 2008 and June 30, 2009. As part of an ongoing prospective outcomes program, procedural times for all vascular procedures (time into until time out of room) were recorded. Fifteen minutes were added for administrative functions on procedural day, each hospital day, and office visits during the global period. The combination of all times was reflected in the total care time (TCT) for each procedure. We recorded all physician fees collected for each procedure. This total fee collected for each procedure was then divided by the TCT to determine the procedure-specific payment per unit time. All similar procedures were grouped together and the average reimbursement per procedure was reported. Data was collected on all 1103 procedures performed during this period. Insurance carrier distribution was 75% Medicare and 25% private insurance. The average reimbursement was $316/hour for open procedures and $556/hour for endovascular. Higher reimbursing procedures included visceral endovascular procedures ($701/hour) and caval filters ($751/hour). Lower reimbursing procedures included lower extremity bypass ($292/hour), dialysis access ($268/hour) and lower extremity amputations ($223/hour). Striking was the difference between payment based on approach for similar conditions. Reimbursement for carotid stent vs carotid endarterectomy was $643/hour vs $383/hour, endovascular abdominal aortic aneurysm (AAA) repair vs open $593/hour vs $359/hour. This unique study demonstrates a "real world" experience of reimbursement per unit time and raises questions as to the validity of the RBRVS process. The disparity between payments for open and endovascular repair of similar conditions are typical of this inequality. These data do not reflect the intangible time of operative planning, administrative matters, or overhead, and these factors must be considered when interpreting this data. Regardless, this study suggests that capturing detailed financial data is possible and is a more accurate source for future discussions on reimbursement. Copyright © 2010 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  18. Epidemiologic Analysis of Elective Operative Procedures in Infants Less Than 6 Months of Age in the United States.

    PubMed

    Einhorn, Lisa M; Young, Brian J; Routh, Jonathan C; Allori, Alexander C; Tracy, Elisabeth T; Greene, Nathaniel H

    2017-11-01

    This study uses publicly available data to analyze the total number of elective, potentially deferrable operative procedures involving infants <6 months of age in the United States. We investigated the factors associated with the performance of these procedures in this population. The State Ambulatory Surgery Database was used to identify patients in California, North Carolina, New York, and Utah during the years of 2007-2010 who were younger than 6 months of age at the time that they underwent outpatient (ambulatory) surgery. Operations that could reasonably be postponed until 6 months of age were classified as potentially deferrable procedures. Hernia repairs were analyzed separately from other deferrable procedures. Primary outcomes included the total number of elective procedures and the number and rates of potentially deferrable procedures per state per year in this population. Over the study period, a total of 27,540 procedures were identified as meeting inclusion criteria; of those, 7832 (28%) were classified as potentially deferrable, 4315 of which were hernia repairs. The average rates of potentially deferrable nonhernia procedures in California, North Carolina, New York, and Utah were 8.3, 43.8, 30.0, and 11.7 per 10,000 person-years, respectively. In multivariable analysis, private insurance (odds ratio [OR] = 1.36), self-pay status (OR = 1.50), and treatment in a different state (OR = 0.48-3.16) were independent predictors of a potentially deferrable procedure being performed on an infant younger than 6 months. Potentially deferrable procedures are still performed in infants <6 months of age. There appears to be significant variation in timing of these procedures among states. Insurance status and geography may be independent predictors of a procedure being potentially deferrable.

  19. Learning curve for peroral endoscopic myotomy

    PubMed Central

    El Zein, Mohamad; Kumbhari, Vivek; Ngamruengphong, Saowanee; Carson, Kathryn A.; Stein, Ellen; Tieu, Alan; Chaveze, Yamile; Ismail, Amr; Dhalla, Sameer; Clarke, John; Kalloo, Anthony; Canto, Marcia Irene; Khashab, Mouen A.

    2016-01-01

    Background and study aims: Although peroral endoscopic myotomy (POEM) is being performed more frequently, the learning curve for gastroenterologists performing the procedure has not been well studied. The aims of this study were to define the learning curve for POEM and determine which preoperative and intraoperative factors predict the time that will be taken to complete the procedure and its different steps. Patients and methods: Consecutive patients who underwent POEM performed by a single expert gastroenterologist for the treatment of achalasia or spastic esophageal disorders were included. The POEM procedure was divided into four steps: mucosal entry, submucosal tunneling, myotomy, and closure. Nonlinear regression was used to determine the POEM learning plateau and calculate the learning rate. Results: A total of 60 consecutive patients underwent POEM in an endoscopy suite. The median length of procedure (LOP) was 88 minutes (range 36 – 210), and the mean (± standard deviation [SD]) LOP per centimeter of myotomy was 9 ± 5 minutes. The total operative time decreased significantly as experience increased (P < 0.001), with a “learning plateau” at 102 minutes and a “learning rate” of 13 cases. The mucosal entry, tunneling, and closure times decreased significantly with experience (P < 0.001). The myotomy time showed no significant decrease with experience (P = 0.35). When the mean (± SD) total procedure times for the learning phase and the corresponding comparator groups were compared, a statistically significant difference was observed between procedures 11 – 15 and procedures 16 – 20 (15.5 ± 2.4 min/cm and 10.1 ± 2.7 min/cm, P = 0.01) but not thereafter. A higher case number was significantly associated with a decreased LOP (P < 0.001). Conclusion: In this single-center retrospective study, the minimum threshold number of cases required for an expert interventional endoscopist performing POEM to reach a plateau approached 13. PMID:27227118

  20. Dual-Axis Rotational Angiography is Safe and Feasible to Detect Coronary Allograft Vasculopathy in Pediatric Heart Transplant Patients: A Single-Center Experience.

    PubMed

    Rios, Rodrigo; Loomba, Rohit S; Foerster, Susan R; Pelech, Andrew N; Gudausky, Todd M

    2016-04-01

    Coronary allograft vasculopathy (CAV) is the leading cause of graft failure in pediatric heart transplant recipients, also adding to mortality in this patient population. Coronary angiography is routinely performed to screen for CAV, with conventional single-plane or bi-plane angiography being utilized. Dual-axis rotational coronary angiography (RA) has been described, mostly in the adult population, and may offer reduction in radiation dose and contrast volume. Experience with this in the pediatric population is limited. This study describes a single-institution experience with RA for screening for CAV in pediatric patients. The catheterization database at our institution was used to identify pediatric heart transplant recipients having undergone RA to screen for CAV. Procedural data including radiation dose, fluoroscopy time, contrast volume, and procedure time were collected for each catheterization. The number of instances in which RA was not successful, ECG changes were present, and CAV was detected were also collected for each catheterization. A total of 97 patients underwent 345 catheterizations utilizing RA. Median radiation dose-area product per kilogram was found to be 341.7 (mGy cm(2)/kg), total air kerma was 126.8 (mGy), procedure time was 69 min, fluoroscopy time was 9.9 min, and contrast volume was 13 ml. A total of 17 (2 %) coronary artery injections out of 690 could not be successfully imaged using RA. A total of 14 patients had CAV noted at any point, 10 of whom had progressive CAV. Electrocardiographic changes were documented in a total of 10 (3 %) RA catheterizations. Procedural characteristics did not differ between serial catheterizations. RA is safe and feasible for CAV screening in pediatric heart transplant recipients while offering coronary imaging in multiple planes compared to conventional angiography.

  1. Effective and efficient learning in the operating theater with intraoperative video-enhanced surgical procedure training.

    PubMed

    van Det, M J; Meijerink, W J H J; Hoff, C; Middel, B; Pierie, J P E N

    2013-08-01

    INtraoperative Video Enhanced Surgical procedure Training (INVEST) is a new training method designed to improve the transition from basic skills training in a skills lab to procedural training in the operating theater. Traditionally, the master-apprentice model (MAM) is used for procedural training in the operating theater, but this model lacks uniformity and efficiency at the beginning of the learning curve. This study was designed to investigate the effectiveness and efficiency of INVEST compared to MAM. Ten surgical residents with no laparoscopic experience were recruited for a laparoscopic cholecystectomy training curriculum either by the MAM or with INVEST. After a uniform course in basic laparoscopic skills, each trainee performed six cholecystectomies that were digitally recorded. For 14 steps of the procedure, an observer who was blinded for the type of training determined whether the step was performed entirely by the trainee (2 points), partially by the trainee (1 point), or by the supervisor (0 points). Time measurements revealed the total procedure time and the amount of effective procedure time during which the trainee acted as the operating surgeon. Results were compared between both groups. Trainees in the INVEST group were awarded statistically significant more points (115.8 vs. 70.2; p < 0.001) and performed more steps without the interference of the supervisor (46.6 vs. 18.8; p < 0.001). Total procedure time was not lengthened by INVEST, and the part performed by trainees was significantly larger (69.9 vs. 54.1 %; p = 0.004). INVEST enhances effectiveness and training efficiency for procedural training inside the operating theater without compromising operating theater time efficiency.

  2. Administrative Costs Associated With Physician Billing and Insurance-Related Activities at an Academic Health Care System.

    PubMed

    Tseng, Phillip; Kaplan, Robert S; Richman, Barak D; Shah, Mahek A; Schulman, Kevin A

    2018-02-20

    Administrative costs in the US health care system are an important component of total health care spending, and a substantial proportion of these costs are attributable to billing and insurance-related activities. To examine and estimate the administrative costs associated with physician billing activities in a large academic health care system with a certified electronic health record system. This study used time-driven activity-based costing. Interviews were conducted with 27 health system administrators and 34 physicians in 2016 and 2017 to construct a process map charting the path of an insurance claim through the revenue cycle management process. These data were used to calculate the cost for each major billing and insurance-related activity and were aggregated to estimate the health system's total cost of processing an insurance claim. Estimated time required to perform billing and insurance-related activities, based on interviews with management personnel and physicians. Estimated billing and insurance-related costs for 5 types of patient encounters: primary care visits, discharged emergency department visits, general medicine inpatient stays, ambulatory surgical procedures, and inpatient surgical procedures. Estimated processing time and total costs for billing and insurance-related activities were 13 minutes and $20.49 for a primary care visit, 32 minutes and $61.54 for a discharged emergency department visit, 73 minutes and $124.26 for a general inpatient stay, 75 minutes and $170.40 for an ambulatory surgical procedure, and 100 minutes and $215.10 for an inpatient surgical procedure. Of these totals, time and costs for activities carried out by physicians were estimated at a median of 3 minutes or $6.36 for a primary care visit, 3 minutes or $10.97 for an emergency department visit, 5 minutes or $13.29 for a general inpatient stay, 15 minutes or $51.20 for an ambulatory surgical procedure, and 15 minutes or $51.20 for an inpatient surgical procedure. Of professional revenue, professional billing costs were estimated to represent 14.5% for primary care visits, 25.2% for emergency department visits, 8.0% for general medicine inpatient stays, 13.4% for ambulatory surgical procedures, and 3.1% for inpatient surgical procedures. In a time-driven activity-based costing study in a large academic health care system with a certified electronic health record system, the estimated costs of billing and insurance-related activities ranged from $20 for a primary care visit to $215 for an inpatient surgical procedure. Knowledge of how specific billing and insurance-related activities contribute to administrative costs may help inform policy solutions to reduce these expenses.

  3. PRN 98-6: Flammability Labeling Requirements for Total Release Fogger Pesticides

    EPA Pesticide Factsheets

    This notice describes new labeling requirements for total release foggers and provides the procedures and time frame for compliance. It ONLY affects total release foggers containing a propellant with a flash point at or below 20 degrees Fahrenheit.

  4. Estimating total suspended sediment yield with probability sampling

    Treesearch

    Robert B. Thomas

    1985-01-01

    The ""Selection At List Time"" (SALT) scheme controls sampling of concentration for estimating total suspended sediment yield. The probability of taking a sample is proportional to its estimated contribution to total suspended sediment discharge. This procedure gives unbiased estimates of total suspended sediment yield and the variance of the...

  5. Operating room waste: disposable supply utilization in neurointerventional procedures.

    PubMed

    Rigante, Luigi; Moudrous, Walid; de Vries, Joost; Grotenhuis, André J; Boogaarts, Hieronymus D

    2017-12-01

    Operating rooms account for 70% of hospital waste, increasing healthcare costs and creating environmental hazards. Endovascular treatment of cerebrovascular pathologies has become prominent, and associated products highly impact the total cost of care. We investigated the costs of endovascular surgical waste at our institution. Data from 53 consecutive endovascular procedures at the Radboud UMC Nijmegen from May to December 2016 were collected. "Unused disposable supply" was defined as one-time use items opened but not used during the procedure. Two observers cataloged the unused disposable supply for each case. The cost of each item was determined from the center supply catalog, and these costs were summed to determine the total cost of unused supply per case. Thirteen diagnostic cerebral digital subtraction angiographies (DSA) (24.5%) and 40 endovascular procedures (75.5%) were analyzed. Total interventional waste was 27,299.53 € (mean 515.09 € per procedure). While total costs of unused disposable supply were almost irrelevant for DSAs, they were consistent for interventional procedures (mean 676.49 € per case). Aneurysm standard coiling had the highest impact on total interventional waste (mean 1061.55 €). Disposable interventional products had a very high impact on the surgical waste costs in the series of the neurointerventional procedures (95% of total waste). This study shows the impact of neurointerventional waste on the total care costs for cerebrovascular patients. This might reflect the tendency to anticipate needs and emergencies in neurointervention. Responsible use of disposable material can be achieved by educating operators and nurses and creating operator preference cards.

  6. Comparison of 1997 Medicare relative value units for gender-specific procedures: is Adam still worth more than Eve?

    PubMed

    Goff, B A; Muntz, H G; Cain, J M

    1997-08-01

    On January 1, 1992, Congress implemented a Medicare payment system based on relative value units (RVUs). The total RVU (which is made up of work, practice, and malpractice RVUs) is multiplied by a dollar conversion factor to set the reimbursement for all procedures covered by Medicare. In a previous study, we found that significant gender bias exists in Medicare reimbursement for female-specific services. Recently, HCFA approved increases (beginning January 1997) in the work RVU for many gynecologic procedures. This study was undertaken to compare work and total RVUs for gender-specific procedures effective January 1, 1997. Using the May 1996 Federal Register, we compared work and total RVUs for 24 pairs of gender-specific procedures. The groups were matched so that the amount of work and level of difficulty would be similar, if not identical. We validated our selection of procedures for comparison by also evaluating the average time required to perform these procedures. Comparison of work RVUs for the 24 paired procedures revealed that in 19 cases (80%), male-specific procedures had a higher RVU; in 3 cases (12%), female-specific procedures were higher; and in 2 cases, there was no difference. On average, work RVUs were 49% higher for urologic procedures than for gynecologic procedures. Comparison of total RVUs revealed that in 20 cases (83%), urologic procedures had a higher total RVU and in 3 cases (12%), gynecologic procedures were higher. On average, male-specific surgeries are reimbursed at an amount which is 37% higher than that for female-specific surgeries. Recent increases in work RVUs for many gynecologic procedures have resulted in improved reimbursement. However, even with these improvements, significant gender bias still exists in the Medicare reimbursement of female-specific procedures. This gender bias is further magnified as more private insurance carriers use the system to set reimbursement.

  7. Simultaneous bilateral stereotactic procedure for deep brain stimulation implants: a significant step for reducing operation time.

    PubMed

    Fonoff, Erich Talamoni; Azevedo, Angelo; Angelos, Jairo Silva Dos; Martinez, Raquel Chacon Ruiz; Navarro, Jessie; Reis, Paul Rodrigo; Sepulveda, Miguel Ernesto San Martin; Cury, Rubens Gisbert; Ghilardi, Maria Gabriela Dos Santos; Teixeira, Manoel Jacobsen; Lopez, William Omar Contreras

    2016-07-01

    OBJECT Currently, bilateral procedures involve 2 sequential implants in each of the hemispheres. The present report demonstrates the feasibility of simultaneous bilateral procedures during the implantation of deep brain stimulation (DBS) leads. METHODS Fifty-seven patients with movement disorders underwent bilateral DBS implantation in the same study period. The authors compared the time required for the surgical implantation of deep brain electrodes in 2 randomly assigned groups. One group of 28 patients underwent traditional sequential electrode implantation, and the other 29 patients underwent simultaneous bilateral implantation. Clinical outcomes of the patients with Parkinson's disease (PD) who had undergone DBS implantation of the subthalamic nucleus using either of the 2 techniques were compared. RESULTS Overall, a reduction of 38.51% in total operating time for the simultaneous bilateral group (136.4 ± 20.93 minutes) as compared with that for the traditional consecutive approach (220.3 ± 27.58 minutes) was observed. Regarding clinical outcomes in the PD patients who underwent subthalamic nucleus DBS implantation, comparing the preoperative off-medication condition with the off-medication/on-stimulation condition 1 year after the surgery in both procedure groups, there was a mean 47.8% ± 9.5% improvement in the Unified Parkinson's Disease Rating Scale Part III (UPDRS-III) score in the simultaneous group, while the sequential group experienced 47.5% ± 15.8% improvement (p = 0.96). Moreover, a marked reduction in the levodopa-equivalent dose from preoperatively to postoperatively was similar in these 2 groups. The simultaneous bilateral procedure presented major advantages over the traditional sequential approach, with a shorter total operating time. CONCLUSIONS A simultaneous stereotactic approach significantly reduces the operation time in bilateral DBS procedures, resulting in decreased microrecording time, contributing to the optimization of functional stereotactic procedures.

  8. Efficiency of Core Biopsy for BI-RADS-5 Breast Lesions.

    PubMed

    Wolf, Ronald; Quan, Glenda; Calhoun, Kris; Soot, Laurel; Skokan, Laurie

    2008-01-01

    Stereotactic biopsy has proven more cost effective for biopsy of lesions associated with moderately suspicious mammograms. Data regarding selection of stereotactic biopsy (CORE) instead of excisional biopsy (EB) as the first diagnostic procedure in patients with nonpalpable breast lesions and highest suspicion breast imaging-reporting and data system (BI-RADS)-5 mammograms are sparse. Records from a regional health system radiology database were screened for mammograms associated with image-guided biopsy. A total of 182 nonpalpable BI-RADS-5 lesions were sampled in 178 patients over 5 years, using CORE or EB. Initial surgical margins, number of surgeries, time from initial procedure to last related surgical procedure, and hospital and professional charges for related admissions were compared using chi-squared, t-test, and Wilcoxon Mann-Whitney tests. A total of 108 CORE and 74 EB were performed as the first diagnostic procedure. Invasive or in situ carcinoma was diagnosed in 156 (86%) of all biopsies, 95 in CORE and 61 in EB groups. Negative margins of the first surgical procedure were more frequent in CORE (n = 70, 74%) versus EB (n = 17, 28%), p < 0.05. Use of CORE was associated with fewer total surgical procedures per lesion (1.29 +/- 0.05 versus 1.8 +/- 0.05, p < 0.05). Time of initial diagnostic procedure to final treatment did not vary significantly according to group (27 +/- 2 days versus 22 +/- 2 days, CORE versus EB). Mean charges including the diagnostic procedure and all subsequent surgeries were not different between CORE and EB groups ($10,500 +/- 300 versus $11,500 +/- 500, p = 0.08). Use of CORE as the first procedure in patients with highly suspicious mammograms is associated with improved pathologic margins and need for fewer surgical procedures than EB, and should be considered the preferred initial diagnostic approach.

  9. Impact of a Novel Catheter Tracking System on Radiation Exposure during the Procedural Phases of Atrial Fibrillation and Flutter Ablation.

    PubMed

    Malliet, Nicolas; Andrade, Jason G; Khairy, Paul; Thanh, Hien Kiem Nguyen; Venier, Sandrine; Dubuc, Marc; Dyrda, Katia; Guerra, Peter; Mondésert, Blandine; Rivard, Léna; Tadros, Rafik; Talajic, Mario; Thibault, Bernard; Roy, Denis; Macle, Laurent

    2015-07-01

    Fluoroscopic guidance is used to position catheters during cardiac ablation. We evaluated the impact of a novel nonfluoroscopic sensor-guided electromagnetic navigation system (MG) on radiation exposure during catheter ablation of atrial fibrillation (AF) or atrial flutter (AFL). A total of 134 consecutive patients referred for ablation of AF (n = 44) or AFL (n = 90) ablation were prospectively enrolled. In one group the MG system was used for nonfluoroscopic catheter positioning, whereas in the conventional group standard fluoroscopy was utilized. Fluoroscopy times were assessed for each stage of procedure and total radiation exposure was quantified. Patient characteristics were similar between the groups. The procedural end point was achieved in all. Median (interquartile range [IQR]) fluoroscopy times were 12.5 minutes (7.6, 17.4) MG group versus 21.5 minutes (15.3, 23.0) conventional group (P < 0.0001) for AF ablation, and 0.8 minutes (0.4, 2.5) MG group versus 9.9 minutes (5.1, 22.5) conventional group (P < 0.0001) for AFL ablation. Median (IQR) total radiation exposure (μGy·m(2)) was 1,107 (906, 2,033) MG group versus 2,835 (1,688, 3,855) conventional group (P = 0.0001) for AF ablation, and 161 (65, 537) MG group versus 1,651 (796, 4,569) conventional group (P < 0.0001) for AFL ablation. No difference in total procedural time was seen. The use of a novel nonfluoroscopic catheter tracking system is associated with a significant reduction in radiation exposure during AF and AFL ablation (61% and 90% reduction, respectively). In the era of heightened awareness of the importance of radiation reduction, this system represents a safe and efficient tool to decrease radiation exposure during electrophysiological ablation procedures. ©2015 Wiley Periodicals, Inc.

  10. The effect of surgeon and hospital volume on shoulder arthroplasty perioperative quality metrics.

    PubMed

    Singh, Anshu; Yian, Edward H; Dillon, Mark T; Takayanagi, Miwa; Burke, Mary F; Navarro, Ronald A

    2014-08-01

    There has been a significant increase in both the incidence of shoulder arthroplasty and the number of surgeons performing these procedures. Literature regarding the relationship between surgeon or hospital volume and the performance of modern shoulder arthroplasty is limited. This study examines the effect of surgeon or hospital shoulder arthroplasty volume on perioperative metrics related to shoulder hemiarthroplasty, total shoulder arthroplasty, and reverse shoulder arthroplasty. Blood loss, length of stay, and operative time were the main endpoints analyzed. Prospective data were analyzed from a multicenter shoulder arthroplasty registry; 1176 primary shoulder arthroplasty cases were analyzed. Correlation and analysis of covariance were used to examine the association between surgeon and hospital volume and perioperative metrics adjusting for age, sex, and body mass index. Surgeon volume is inversely correlated with length of stay for hemiarthroplasty and total shoulder arthroplasty and with blood loss and operative time for all 3 procedures. Hospital volume is inversely correlated with length of stay for hemiarthroplasty, with blood loss for total and reverse shoulder arthroplasty, and with operative time for all 3 procedures. High-volume surgeons performed shoulder arthroplasty 30 to 50 minutes faster than low-volume surgeons did. Higher surgeon and hospital case volumes led to improved perioperative metrics with all shoulder arthroplasty procedures, including reverse total shoulder arthroplasty, which has not been previously described in the literature. Surgeon volume had a larger effect on metrics than hospital volume did. This study supports the concept that complex shoulder procedures are, on average, performed more efficiently by higher volume surgeons in higher volume centers. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  11. Controversy of hand-assisted laparoscopic colorectal surgery

    PubMed Central

    Meshikhes, Abdul-Wahed Nasir

    2010-01-01

    Laparoscopically assisted colorectal procedures are time-consuming and technically demanding and hence have a long steep learning curve. In the technical demand, surgeons need to handle a long mobile organ, the colon, and have to operate on multiple abdominal quadrants, most of the time with the need to secure multiple mesenteric vessels. Therefore, a new surgical innovation called hand-assisted laparoscopic surgery (HALS) was introduced in the mid 1990s as a useful alternative to totally laparoscopic procedures. This hybrid operation allows the surgeon to introduce the non-dominant hand into the abdominal cavity through a special hand port while maintaining the pneumoperitoneum. A hand in the abdomen can restore the tactile sensation which is usually lacking in laparoscopic procedures. It also improves the eye-to-hand coordination, allows the hand to be used for blunt dissection or retraction and also permits rapid control of unexpected bleeding. All of those factors can contribute tremendously to reducing the operative time. Moreover, this procedure is also considered as a hybrid procedure that combines the advantages of both minimally invasive and conventional open surgery. Nevertheless, the exact role of HALS in colorectal surgery has not been well defined during the advanced totally laparoscopic procedures. This article reviews the current status of hand-assisted laparoscopic colorectal surgery as a minimally invasive procedure in the era of laparoscopic surgery. PMID:21128315

  12. Work intensity in sacroiliac joint fusion and lumbar microdiscectomy

    PubMed Central

    Frank, Clay; Kondrashov, Dimitriy; Meyer, S Craig; Dix, Gary; Lorio, Morgan; Kovalsky, Don; Cher, Daniel

    2016-01-01

    Background The evidence base supporting minimally invasive sacroiliac (SI) joint fusion (SIJF) surgery is increasing. The work relative value units (RVUs) associated with minimally invasive SIJF are seemingly low. To date, only one published study describes the relative work intensity associated with minimally invasive SIJF. No study has compared work intensity vs other commonly performed spine surgery procedures. Methods Charts of 192 patients at five sites who underwent either minimally invasive SIJF (American Medical Association [AMA] CPT® code 27279) or lumbar microdiscectomy (AMA CPT® code 63030) were reviewed. Abstracted were preoperative times associated with diagnosis and patient care, intraoperative parameters including operating room (OR) in/out times and procedure start/stop times, and postoperative care requirements. Additionally, using a visual analog scale, surgeons estimated the intensity of intraoperative care, including mental, temporal, and physical demands and effort and frustration. Work was defined as operative time multiplied by task intensity. Results Patients who underwent minimally invasive SIJF were more likely female. Mean procedure times were lower in SIJF by about 27.8 minutes (P<0.0001) and mean total OR times were lower by 27.9 minutes (P<0.0001), but there was substantial overlap across procedures. Mean preservice and post-service total labor times were longer in minimally invasive SIJF (preservice times longer by 63.5 minutes [P<0.0001] and post-service labor times longer by 20.2 minutes [P<0.0001]). The number of postoperative visits was higher in minimally invasive SIJF. Mean total service time (preoperative + OR time + postoperative) was higher in the minimally invasive SIJF group (261.5 vs 211.9 minutes, P<0.0001). Intraoperative intensity levels were higher for mental, physical, effort, and frustration domains (P<0.0001 each). After taking into account intensity, intraoperative workloads showed substantial overlap. Conclusion Compared to a commonly performed lumbar spine surgical procedure, lumbar microdiscectomy, that currently has a higher work RVU, preoperative, intraoperative, and postoperative workload for minimally invasive SIJF is higher. The work RVU for minimally invasive SIJF should be adjusted upward as the relative amount of work is comparable. PMID:27555790

  13. Hybrid procedure for total laryngectomy with a flexible robot-assisted surgical system.

    PubMed

    Schuler, Patrick J; Hoffmann, Thomas K; Veit, Johannes A; Rotter, Nicole; Friedrich, Daniel T; Greve, Jens; Scheithauer, Marc O

    2017-06-01

    Total laryngectomy is a standard procedure in head-and-neck surgery for the treatment of cancer patients. Recent clinical experiences have indicated a clinical benefit for patients undergoing transoral robot-assisted total laryngectomy (TORS-TL) with commercially available systems. Here, a new hybrid procedure for total laryngectomy is presented. TORS-TL was performed in human cadavers (n = 3) using a transoral-transcervical hybrid procedure. The transoral approach was performed with a robotic flexible robot-assisted surgical system (Flex®) and compatible flexible instruments. Transoral access and visualization of anatomical landmarks were studied in detail. Total laryngectomy is feasible with a combined transoral-transcervical approach using the flexible robot-assisted surgical system. Transoral visualization of all anatomical structures is sufficient. The flexible design of the robot is advantageous for transoral surgery of the laryngeal structures. Transoral robot assisted surgery has the potential to reduce morbidity, hospital time and fistula rates in a selected group of patients. Initial clinical studies and further development of supplemental tools are in progress. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. The effects of the number of rubber bands placed at each endoscopic session upon variceal outcomes: a prospective, randomized study.

    PubMed

    Ramirez, Francisco C; Colon, Victor J; Landan, Derek; Grade, Andrew J; Evanich, Elizabeth

    2007-07-01

    To determine the role of the number of bands placed per session upon patient-related and procedural-related outcomes. Patients were assigned to receive as many bands as could be possibly placed (group 1) or up to a maximum of six bands (group 2) per session. The primary outcome measured was the number of sessions to achieve obliteration. Other outcomes measured included: rebleeding, variceal recurrence, mortality (within 6 wk and within 1 yr), complications, banding and total procedure times, and number of bands misfired. A total of 86 patients were enrolled: 45 in group 1 and 41 in group 2. The two groups had similar age, Child-Pugh scores, grade of varices at entry. The overall proportion of patients achieving obliteration was 56% (53% and 59% for groups 1 and 2, respectively). Despite receiving significantly more mean bands per session, patients in group 1 required similar (mean +/- SEM) number of sessions to obliteration (2.9 +/- 0.3 vs 3.3 +/- 0.3) and total number of bands (20.0 +/- 2.4 vs 16.6 +/- 1.8) to achieve this goal compared with group 2. The overall proportion of patients with variceal rebleeding was 25%, the 1-yr variceal recurrence 31.3%, and the overall early- and 1-yr mortality were 18.6% and 33.7%, respectively. These proportions were similar in the two groups. Banding and total procedure times were significantly longer and associated with significantly more misfired bands per session in group 1. Compared with a maximum of six bands per session, the placement of >6 bands per session was not associated with better patient outcomes but with significantly more prolonged banding and total procedure times and significantly more misfired bands.

  15. The incidence of total hip arthroplasty after hip arthroscopy in osteoarthritic patients

    PubMed Central

    2010-01-01

    Objective To assess the incidence of total hip arthroplasty (THA) in osteoarthritic patients who were treated by arthroscopic debridement and to evaluate factors that might influence the time interval from the first hip arthroscopy to THA. Design Retrospective clinical series Methods Follow-up data and surgical reports were retrieved from 564 records of osteoarthritic patients that have had hip arthroscopy between the years 2002 to 2009 with a mean follow-up time of 3.2 years (range, 1-6.4 years). The time interval between the first hip arthroscopy to THA was modelled as a function of patient age; level of cartilage damage; procedures performed and repeated arthroscopies with the use of multivariate regression analysis. Results Ninety (16%) of all participants eventually required THA. The awaiting time from the first arthroscopy to a hip replacement was found to be longer in patients younger than 55 years and in a milder osteoarthritic stage. Patients that experienced repeated hip scopes had a longer time to THA than those with only a single procedure. Procedures performed concomitant with debridement and lavage did not affect the time interval to THA. Conclusions In our series of arthroscopic treatment of hip osteoarthritis, 16% required THA over a period of 7 years. Factors that influence the time to arthroplasty were age, degree of osteoarthritis and recurrent procedures. PMID:20670440

  16. Application of hydrocyanic acid vapor generation via focused microwave radiation to the preparation of industrial effluent samples prior to free and total cyanide determinations by spectrophotometric flow injection analysis.

    PubMed

    Quaresma, Maria Cristina Baptista; de Carvalho, Maria de Fátima Batista; Meirelles, Francis Assis; Santiago, Vânia Maria Junqueira; Santelli, Ricardo Erthal

    2007-02-01

    A sample preparation procedure for the quantitative determination of free and total cyanides in industrial effluents has been developed that involves hydrocyanic acid vapor generation via focused microwave radiation. Hydrocyanic acid vapor was generated from free cyanides using only 5 min of irradiation time (90 W power) and a purge time of 5 min. The HCN generated was absorbed into an accepting NaOH solution using very simple glassware apparatus that was appropriate for the microwave oven cavity. After that, the cyanide concentration was determined within 90 s using a well-known spectrophotometric flow injection analysis system. Total cyanide analysis required 15 min irradiation time (90 W power), as well as chemical conditions such as the presence of EDTA-acetate buffer solution or ascorbic acid, depending on the effluent to be analyzed (petroleum refinery or electroplating effluents, respectively). The detection limit was 0.018 mg CN l(-1) (quantification limit of 0.05 mg CN l(-1)), and the measured RSD was better than 8% for ten independent analyses of effluent samples (1.4 mg l(-1) cyanide). The accuracy of the procedure was assessed via analyte spiking (with free and complex cyanides) and by performing an independent sample analysis based on the standard methodology recommended by the APHA for comparison. The sample preparation procedure takes only 10 min for free and 20 min for total cyanide, making this procedure much faster than traditional methodologies (conventional heating and distillation), which are time-consuming (they require at least 1 h). Samples from oil (sour and stripping tower bottom waters) and electroplating effluents were analyzed successfully.

  17. Safety and feasibility of single-catheter ablation using remote magnetic navigation for treatment of slow-fast atrioventricular nodal reentrant tachycardia compared to conventional ablation strategies.

    PubMed

    Akca, Ferdi; Schwagten, Bruno; Theuns, Dominic A J; Takens, Marieke; Musters, Paul; Szili-Torok, Tamas

    2013-12-01

    Ablation of atrioventricular nodal re-entrant tachycardia (AVNRT) is a highly effective procedure both with radiofrequency (RF) and cryoenergy (CE). Conventionally, it requires several diagnostic catheters and hospital admission. This study assessed the safety and efficacy of a highly simplified approach using the magnetic navigation system (MNS) compared to CE and manual RF ablation (MAN). In the MNS group a single magnetic-guided quadripolar catheter was inserted through the internal jugular vein to perform ablation. In the CE group cryomapping preceded ablation and for MAN procedures conventional ablation was performed. The following parameters were analysed: success- and recurrence rate, procedure-, fluoroscopy- and total application time. In total 69 eligible patients were treated with MNS (n = 26), CE (n = 25) and MAN (n = 16). The success rates were 100%, 100% and 94%, respectively (p = ns). The mean procedural time was 83 +/- 25 min for MNS, 117 +/- 47 min for CE and 117 +/- 55 min for MAN (P < 0.01). Total radiation time was significantly lower for MNS [0.0 min (IQR 0.0-0.0)] compared to CE [15.1 min (IQR 9.1-23.8), P < 0.001] and MAN [17.5 min (IQR 7.0-31.3), P < 0.001]. The total application time was comparable for both RF groups: 357 +/- 315 s (MNS) vs 204 +/- 177 s (MAN) (P = 0.14). No major adverse events occurred. After 3 months follow-up similar PR intervals were recorded for all patients. During a follow-up of 26 +/- 5 months recurrence rates were 3.8%, 4.0% and 6.3%, respectively, for each group. The MNS-guided single-catheter approach is a feasible and safe technique for the treatment of patients with typical AVNRT.

  18. Total reduction of distorted echelle spectrograms - An automatic procedure. [for computer controlled microdensitometer

    NASA Technical Reports Server (NTRS)

    Peterson, R. C.; Title, A. M.

    1975-01-01

    A total reduction procedure, notable for its use of a computer-controlled microdensitometer for semi-automatically tracing curved spectra, is applied to distorted high-dispersion echelle spectra recorded by an image tube. Microdensitometer specifications are presented and the FORTRAN, TRACEN and SPOTS programs are outlined. The intensity spectrum of the photographic or electrographic plate is plotted on a graphic display. The time requirements are discussed in detail.

  19. Does antegrade JJ stenting affect the total operative time during laparoscopic pyeloplasty?

    PubMed

    Bolat, Mustafa Suat; Çınar, Önder; Akdeniz, Ekrem

    2017-12-01

    We aimed to show the effect of retrograde JJ stenting and intraoperative antegrade JJ stenting techniques on operative time in patients who underwent laparoscopic pyeloplasty. A total of 34 patients were retrospectively investigated (15 male and 19 female) with ureteropelvic junction obstruction. Of the patients stentized under local anesthesia preoperatively, as a part of surgery, 15 were retrogradely stentized at the beginning of the procedure (Group 1), and 19 were antegradely stentized during the procedure (Group 2). A transperitoneal dismembered pyeloplasty technique was performed in all patients. The two groups were retrospectively compared in terms of complications, the mean total operative time, and the mean stenting times. The mean ages of the patients were 31.5±15.5 and 33.2±15.5 years (p=0.09), and the mean body mass indexes were 25.8±5.6 and 26.2.3±8.4 kg/m 2 in Group 1 and Group 2, respectively. The mean total operative times were 128.9±38.9 min and 112.7±21.9 min (p=0.04); the mean stenting times were 12.6±5.4 min and 3.5±2.4 min (p=0.02); and the mean rates of catheterization-to-total surgery times were 0.1 and 0.03 (p=0.01) in Group 1 and 2, respectively. The mean hospital stays and the mean anastomosis times were similar between the two groups (p>0.05). Antegrade JJ stenting during laparoscopic pyeloplasty significantly decreased the total operative time.

  20. Remote magnetic navigation for circumferential pulmonary vein ablation: single-catheter technique or additional use of a circular mapping catheter?

    PubMed

    Vollmann, Dirk; Lüthje, Lars; Seegers, Joachim; Sohns, Christian; Sossalla, Samuel; Sohns, Jan; Röver, Christian; Hasenfuß, Gerd; Zabel, Markus

    2014-10-01

    Remote magnetic navigation (RMN) is utilized for catheter guidance during pulmonary vein ablation (PVA). We aimed to determine whether the additional use of a circular mapping catheter (CMC) influences efficacy and outcome of RMN-guided PVA. A total of 80 consecutive subjects (65 % male, age 62 ± 9 years) underwent circumferential PVA with a 3D mapping system and an RMN-guided irrigated catheter. Procedural endpoint was complete PV isolation (PVI), total radiofrequency (RF) time >60 min, or procedure duration >5 h. PVI was defined as an entrance and/or exit block, diagnosed with a CMC within the PV ostium or by pacing via the roving RMN-guided catheter (single-catheter technique). Prolonged Holter monitoring after 3 and 6 months was used to detect atrial tachyarrhythmia (AT/AF) recurrences. Complete PVI was achieved in 56 % (45/80) of all subjects (isolated PVs per patient, 3.1 ± 1.2; RF time, 56.3 ± 17.2 min; procedure duration, 3.8 ± 0.8 h). Prospective validation of the single-catheter technique for diagnosing PVI demonstrated high concordance (94 %) with blinded CMC results. CMC use in first-time PVA was associated with similar total RF and procedure times but higher PV isolation rate. Upon multivariate analysis, CMC use, female gender, left PV, smaller PV ostium and repeat PVA predicted PVI during RMN-guided ablation. Persistent AF and mitral regurgitation at baseline and the number of non-isolated PVs predicted AT/AF recurrence during follow-up. Concomitant CMC use for first-time, RMN-guided PVA is associated with similar procedure duration but higher PV isolation rates as compared to a single-catheter approach. Since the number of isolated PVs predicts freedom from AT/AF, CMC utilization appears advisable for first-time, RMN-guided PVA.

  1. Total cost comparison of 2 biopsy methods for nonpalpable breast lesions.

    PubMed

    Bodai, B I; Boyd, B; Brown, L; Wadley, H; Zannis, V J; Holzman, M

    2001-05-01

    To identify, quantify, and compare total facility costs for 2 breast biopsy methods: vacuum-assisted biopsy (VAB) and needle-wire-localized open surgical biopsy (OSB). A time-and-motion study was done to identify unit resources used in both procedures. Costs were imputed from published literature to value resources. A comparison of the total (fixed and variable) costs of the 2 procedures was done. A convenience sample of 2 high-volume breast biopsy (both VAB and OSB) facilities was identified. A third facility (OSB only) and 8 other sites (VAB only) were used to capture variation. Staff interviews, patient medical records, and billing data were used to check observed data. One hundred and sixty-seven uncomplicated procedures (71 OSBs, 96 VABs) were observed. Available demographic and clinical data were analyzed to assess selection bias, and sensitivity analyses were done on the main assumptions. The total facility costs of the VAB procedure were lower than the costs of the OSB procedure. The overall cost advantage for using VAB ranges from $314 to $843 per procedure depending on the facility type. Variable cost comparison indicated little difference between the 2 procedures. The largest fixed cost difference was $763. Facilities must consider the cost of new technology, especially when the new technology is as effective as the present technology. The seemingly high cost of equipment might negatively influence a decision to adopt VAB, but when total facility costs were analyzed, the new technology was less costly.

  2. Trends, Predictors, and Outcomes of Healthcare Resources Used in Patients Hospitalized with Alzheimer's Disease with at Least One Procedure: The Nationwide Inpatient Sample.

    PubMed

    Beydoun, May A; Gamaldo, Alyssa A; Beydoun, Hind A; Shaked, Danielle; Zonderman, Alan B; Eid, Shaker M

    2017-01-01

    We assessed trends, predictors and outcomes of resource utilization in hospital inpatient discharges with a principal diagnosis of Alzheimer's disease (AD) with at least one procedure. Using Nationwide Inpatient Sample data (NIS, 2002-2012), discharges primarily diagnosed with AD, aged ≥60 y and with ≥1 procedure, were selected (Weighted N = 92,300). Hospital resource utilization were assessed using ICD-9-CM codes, while hospitalization outcomes included total charges (TC, 2012$), length of stay (LOS, days), and mortality risk (MR, %). Brain and respiratory/gastrointestinal procedure utilization both dropped annually by 3-7%, while cardiovascular procedures/evaluations, blood evaluations, blood transfusion, and resuscitation ("CVD/Blood") as well as neurophysiological and psychological evaluation and treatment ("Neuro") procedures increased by 5-8%. Total charges, length of stay, and mortality risk were all markedly higher with use of respiratory/gastrointestinal procedures as opposed to being reduced with use of "Brain" procedures. Procedure count was positively associated with all three hospitalization outcomes. In sum, patterns of hospital resources that were used among AD inpatients changed over-time, and were associated with hospitalization outcomes such as total charges, length of stay, and mortality risk.

  3. A transition from using multi-step procedures to a fully integrated system for performing extracorporeal photopheresis: A comparison of costs and efficiencies.

    PubMed

    Azar, Nabih; Leblond, Veronique; Ouzegdouh, Maya; Button, Paul

    2017-12-01

    The Pitié Salpêtrière Hospital Hemobiotherapy Department, Paris, France, has been providing extracorporeal photopheresis (ECP) since November 2011, and started using the Therakos ® CELLEX ® fully integrated system in 2012. This report summarizes our single-center experience of transitioning from the use of multi-step ECP procedures to the fully integrated ECP system, considering the capacity and cost implications. The total number of ECP procedures performed 2011-2015 was derived from department records. The time taken to complete a single ECP treatment using a multi-step technique and the fully integrated system at our department was assessed. Resource costs (2014€) were obtained for materials and calculated for personnel time required. Time-driven activity-based costing methods were applied to provide a cost comparison. The number of ECP treatments per year increased from 225 (2012) to 727 (2015). The single multi-step procedure took 270 min compared to 120 min for the fully integrated system. The total calculated per-session cost of performing ECP using the multi-step procedure was greater than with the CELLEX ® system (€1,429.37 and €1,264.70 per treatment, respectively). For hospitals considering a transition from multi-step procedures to fully integrated methods for ECP where cost may be a barrier, time-driven activity-based costing should be utilized to gain a more comprehensive understanding the full benefit that such a transition offers. The example from our department confirmed that there were not just cost and time savings, but that the time efficiencies gained with CELLEX ® allow for more patient treatments per year. © 2017 The Authors Journal of Clinical Apheresis Published by Wiley Periodicals, Inc.

  4. Estimating times of surgeries with two component procedures: comparison of the lognormal and normal models.

    PubMed

    Strum, David P; May, Jerrold H; Sampson, Allan R; Vargas, Luis G; Spangler, William E

    2003-01-01

    Variability inherent in the duration of surgical procedures complicates surgical scheduling. Modeling the duration and variability of surgeries might improve time estimates. Accurate time estimates are important operationally to improve utilization, reduce costs, and identify surgeries that might be considered outliers. Surgeries with multiple procedures are difficult to model because they are difficult to segment into homogenous groups and because they are performed less frequently than single-procedure surgeries. The authors studied, retrospectively, 10,740 surgeries each with exactly two CPTs and 46,322 surgical cases with only one CPT from a large teaching hospital to determine if the distribution of dual-procedure surgery times fit more closely a lognormal or a normal model. The authors tested model goodness of fit to their data using Shapiro-Wilk tests, studied factors affecting the variability of time estimates, and examined the impact of coding permutations (ordered combinations) on modeling. The Shapiro-Wilk tests indicated that the lognormal model is statistically superior to the normal model for modeling dual-procedure surgeries. Permutations of component codes did not appear to differ significantly with respect to total procedure time and surgical time. To improve individual models for infrequent dual-procedure surgeries, permutations may be reduced and estimates may be based on the longest component procedure and type of anesthesia. The authors recommend use of the lognormal model for estimating surgical times for surgeries with two component procedures. Their results help legitimize the use of log transforms to normalize surgical procedure times prior to hypothesis testing using linear statistical models. Multiple-procedure surgeries may be modeled using the longest (statistically most important) component procedure and type of anesthesia.

  5. Surgeon and type of anesthesia predict variability in surgical procedure times.

    PubMed

    Strum, D P; Sampson, A R; May, J H; Vargas, L G

    2000-05-01

    Variability in surgical procedure times increases the cost of healthcare delivery by increasing both the underutilization and overutilization of expensive surgical resources. To reduce variability in surgical procedure times, we must identify and study its sources. Our data set consisted of all surgeries performed over a 7-yr period at a large teaching hospital, resulting in 46,322 surgical cases. To study factors associated with variability in surgical procedure times, data mining techniques were used to segment and focus the data so that the analyses would be both technically and intellectually feasible. The data were subdivided into 40 representative segments of manageable size and variability based on headers adopted from the common procedural terminology classification. Each data segment was then analyzed using a main-effects linear model to identify and quantify specific sources of variability in surgical procedure times. The single most important source of variability in surgical procedure times was surgeon effect. Type of anesthesia, age, gender, and American Society of Anesthesiologists risk class were additional sources of variability. Intrinsic case-specific variability, unexplained by any of the preceding factors, was found to be highest for shorter surgeries relative to longer procedures. Variability in procedure times among surgeons was a multiplicative function (proportionate to time) of surgical time and total procedure time, such that as procedure times increased, variability in surgeons' surgical time increased proportionately. Surgeon-specific variability should be considered when building scheduling heuristics for longer surgeries. Results concerning variability in surgical procedure times due to factors such as type of anesthesia, age, gender, and American Society of Anesthesiologists risk class may be extrapolated to scheduling in other institutions, although specifics on individual surgeons may not. This research identifies factors associated with variability in surgical procedure times, knowledge of which may ultimately be used to improve surgical scheduling and operating room utilization.

  6. Surgical problems and complex procedures: issues for operative time in robotic totally endoscopic coronary artery bypass grafting.

    PubMed

    Wiedemann, Dominik; Bonaros, Nikolaos; Schachner, Thomas; Weidinger, Felix; Lehr, Eric J; Vesely, Mark; Bonatti, Johannes

    2012-03-01

    Robotically assisted totally endoscopic coronary artery bypass grafting (TECAB) is a viable option for closed chest coronary surgery, but it requires learning curves and longer operative times. This study evaluated the effect of extended operation times on the outcome of patients undergoing TECAB. From 2001 to 2009, 325 patients underwent TECAB with the da Vinci telemanipulation system. Correlations between operative times and preoperative, intraoperative, and early postoperative parameters were investigated. Receiver operating characteristic analysis was used to define the threshold of the procedure duration above which intensive care unit stay and ventilation time were prolonged. Demographic data, intraoperative and postoperative parameters, and survival data were compared. Patients with prolonged operative times more often underwent multivessel revascularization (P < .001) and beating-heart TECAB (P =.023). Other preoperative parameters were not associated with longer operative times. Incidences of technical difficulties and conversions (P < .001) were higher among patients with longer operative times. Prolonged intensive care unit stay, mechanical ventilation, hospital stay, and with requirement of blood products were associated with longer operative times. Receiver operating characteristic analysis showed operative times >445 minutes and >478 minutes to predict prolonged (>48 hours) intensive care unit stay and mechanical ventilation, respectively. Patients with procedures >478 minutes had longer hospital stays and higher perioperative morbidity and mortality. Kaplan-Meier analysis revealed decreased survival among patients with operative times >478 minutes. Multivessel revascularization and conversions lead to prolonged operative times in totally endoscopic coronary artery bypass grafting. Longer operative times significantly influence early postoperative and midterm outcomes. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  7. Radiologists' Variation of Time to Read Across Different Procedure Types.

    PubMed

    Forsberg, Daniel; Rosipko, Beverly; Sunshine, Jeffrey L

    2017-02-01

    The workload of US radiologists has increased over the past two decades as measured through total annual relative value units (RVUs). This increase in RVUs generated suggests that radiologists' productivity has increased. However, true productivity (output unit per input unit; RVU per time) is at large unknown since actual time required to interpret and report a case is rarely recorded. In this study, we analyzed how the time to read a case varies between radiologists over a set of different procedure types by retrospectively extracting reading times from PACS usage logs. Specifically, we tested two hypotheses that; i) relative variation in time to read per procedure type increases as the median time to read a procedure type increases, and ii) relative rankings in terms of median reading speed for individual radiologists are consistent across different procedure types. The results that, i) a correlation of -0.25 between the coefficient of variation and median time to read and ii) that only 12 out of 46 radiologists had consistent rankings in terms of time to read across different procedure types, show both hypotheses to be without support. The results show that workload distribution will not follow any general rule for a radiologist across all procedures or a general rule for a specific procedure across many readers. Rather the findings suggest that improved overall practice efficiency can be achieved only by taking into account radiologists' individual productivity per procedure type when distributing unread cases.

  8. Use of an operating microscope during spine surgery is associated with minor increases in operating room times and no increased risk of infection.

    PubMed

    Basques, Bryce A; Golinvaux, Nicholas S; Bohl, Daniel D; Yacob, Alem; Toy, Jason O; Varthi, Arya G; Grauer, Jonathan N

    2014-10-15

    Retrospective database review. To evaluate whether microscope use during spine procedures is associated with increased operating room times or increased risk of infection. Operating microscopes are commonly used in spine procedures. It is debated whether the use of an operating microscope increases operating room time or confers increased risk of infection. The American College of Surgeons National Surgical Quality Improvement Program database, which includes data from more than 370 participating hospitals, was used to identify patients undergoing elective spinal procedures with and without the use of an operating microscope for the years 2011 and 2012. Bivariate and multivariate linear regressions were used to test the association between microscope use and operating room times. Bivariate and multivariate logistic regressions were similarly conducted to test the association between microscope use and infection occurrence within 30 days of surgery. A total of 23,670 elective spine procedures were identified, of which 2226 (9.4%) used an operating microscope. The average patient age was 55.1±14.4 years. The average operative time (incision to closure) was 125.7±82.0 minutes.Microscope use was associated with minor increases in preoperative room time (+2.9 min, P=0.013), operative time (+13.2 min, P<0.001), and total room time (+18.6 min, P<0.001) on multivariate analysis.A total of 328 (1.4%) patients had an infection within 30 days of surgery. Multivariate analysis revealed no significant difference between the microscope and nonmicroscope groups for occurrence of any infection, superficial surgical site infection, deep surgical site infection, organ space infection, or sepsis/septic shock, regardless of surgery type. We did not find operating room times or infection risk to be significant deterrents for use of an operating microscope during spine surgery. 3.

  9. Use of an operating microscope during spine surgery is associated with minor increases in operating room times and no increased risk of infection

    PubMed Central

    Basques, Bryce A.; Golinvaux, Nicholas S.; Bohl, Daniel D.; Yacob, Alem; Toy, Jason O.; Varthi, Arya G.; Grauer, Jonathan N.

    2014-01-01

    Study Design Retrospective database review. Objective To evaluate whether microscope use during spine procedures is associated with increased operating room times or increased risk of infection. Summary of Background Data Operating microscopes are commonly used in spine procedures. It is debated whether the use of an operating microscope increases operating room time or confers increased risk of infection. Methods The American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) database, which includes data from over 370 participating hospitals, was used to identify patients undergoing elective spinal procedures with and without an operating microscope for the years 2011 and 2012. Bivariate and multivariate linear regressions were used to test the association between microscope use and operating room times. Bivariate and multivariate logistic regressions were similarly conducted to test the association between microscope use and infection occurrence within 30 days of surgery. Results A total of 23,670 elective spine procedures were identified, of which 2,226 (9.4%) used an operating microscope. The average patient age was 55.1 ± 14.4 years. The average operative time (incision to closure) was 125.7 ± 82.0 minutes. Microscope use was associated with minor increases in preoperative room time (+2.9 minutes, p=0.013), operative time (+13.2 minutes, p<0.001), and total room time (+18.6 minutes, p<0.001) on multivariate analysis. A total of 328 (1.4%) patients had an infection within 30 days of surgery. Multivariate analysis revealed no significant difference between the microscope and non-microscope groups for occurrence of any infection, superficial surgical site infection (SSI), deep SSI, organ space infection, or sepsis/septic shock, regardless of surgery type. Conclusions We did not find operating room times or infection risk to be significant deterrents for use of an operating microscope during spine surgery. PMID:25188600

  10. Management of Osseous and Soft-Tissue Ankle Equinus During Total Ankle Replacement.

    PubMed

    Roukis, Thomas S; Simonson, Devin C

    2015-10-01

    Obtaining functional alignment of a total ankle replacement, including physiologic sagittal plane range of motion, is paramount for a successful outcome. This article reviews the literature on techniques available for correction of osseous and soft-tissue equinus at the time of index total ankle replacement. These techniques include anterior tibiotalar joint cheilectomy, posterior superficial muscle compartment lengthening, posterior ankle capsule release, and release of the posterior portions of the medial and lateral collateral ligament complexes. The rationale for these procedures and the operative sequence of events for these procedures are presented. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Safety of interventional rigid bronchoscopy using intravenous anesthesia and spontaneous assisted ventilation. A prospective study.

    PubMed

    Perrin, G; Colt, H G; Martin, C; Mak, M A; Dumon, J F; Gouin, F

    1992-11-01

    To investigate the safety of total intravenous anesthesia and spontaneous assisted ventilation during interventional rigid bronchoscopy (IRB). Prospective, noncomparative study. A university hospital thoracic endoscopy and laser center. Eighty-three patients underwent a total of 124 procedures (including Nd:Yag laser therapy, stent insertions, transbronchial biopsies/bronchoalveolar lavages (TBB/BALs) in transplant patients and others). Results of preanesthesia consultation, endoscopic and anesthesia intervention, perioperative complications, and time spent in recovery room were recorded prospectively. Respiratory complications occurred in 22 procedures (18 percent) and included severe intraoperative or postoperative oxyhemoglobin desaturations (19 cases), bronchospasms/laryngospasms (two cases), and one recurrent pneumothorax. These complications were mostly related to the endobronchial surgical procedure. Respiratory complications occurred more frequently in patients with American Society of Anesthesiologists (ASA) 3 and 4 status (p < 0.005) and in patients with a karnofsky Performance Scale (KPS) below 70 (p < 0.05). No cardiac complications were noted, although 13 patients had significant underlying heart disease. Propofol was used in 121 procedures. Etomidate was used 15 times for induction and three times for both induction and maintenance in patients with ASA status 4 or low blood pressure before induction. Total intravenous anesthesia and spontaneous assisted ventilation is a well-suited technique for IRB. Severe hypoxemia, however, may occur in approximately 15 percent of patients. This complication is usually related to the procedure itself and is easy to reverse. Propofol is well tolerated in the majority of patients but it must be used with care in patients with poor functional or cardiovascular status.

  12. Effectiveness of a reusable low-cost balloon trocar dissection device in the creation of preperitoneal space during endoscopic surgery. An experimental study in swine.

    PubMed

    Nácul, Miguel Prestes; Cavazzola, Leandro Totti; Loureiro, Marcelo de Paula; Bonin, Eduardo Aimoré; Ferreira, Paulo Roberto Walter

    2015-09-01

    To evaluate a new, low-cost, reusable balloon trocar device for dissection of the preperitoneal space during endoscopic surgery. Twenty swine (weight: 15-37 kg) were randomized to two groups, according to whether the preperitoneal space was created with a new balloon device manufactured by Bhio-Supply (group B) or with the commercially available OMSPDB 1000® balloon device manufactured by Covidien (group C). Quality and size of the created preperitoneal space, identification of anatomic structures, balloon dissection time, total procedure time, balloon resistance and internal pressure after insufflation with 300 mL of ambient air, balloon-related complications, and procedure cost were assessed. No significant differences in dissection time, total procedure time, or size of the created preperitoneal space were found between the groups. Balloons in group B had a significantly higher internal pressure compared to balloons in group C. None of the balloons ruptured during the experiment. Three animals in group C had balloon-related peritoneal lacerations. Despite a higher individual device cost, group B had a lower procedure cost over the entire experiment. The new balloon device is not inferior to the commercially available device in terms of the safety and effectiveness for creating a preperitoneal space in swine.

  13. Prospective, randomized comparison of a prototype endoscope with deflecting working channels versus a conventional double-channel endoscope for rectal endoscopic submucosal dissection in an established experimental simulation model (with video).

    PubMed

    Jung, Yunho; Kato, Masayuki; Lee, Jongchan; Gromski, Mark A; Chuttani, Ram; Matthes, Kai

    2013-11-01

    A prototype endoscope was designed to improve visualization and dissection of tissue with the use of 2 working channels with different deflections. To evaluate the efficacy and operability of a prototype endoscope in comparison with a conventional double-channel endoscope for rectal endoscopic submucosal dissection (ESD). Randomized, prospective, controlled, ex vivo study. Academic medical center. A total of 80 standardized artificial lesions measuring 3 × 3 cm were created approximately 5 cm from the anal verge in fresh ex vivo porcine colorectal specimens. Two endoscopists each completed 20 cases with the prototype endoscope and 20 cases with the conventional endoscope. An independent observer recorded procedure time, specimen size, en bloc resection, and perforation rate. For the ESD novice, the mean submucosal dissection time (10.5 ± 3.8 vs 14.9 ± 7.3 minutes; P = .024) and total procedure time (18.1 ± 5.2 vs 23.6 ± 8.2 minutes; P = .015) were significantly shorter in the prototype group in comparison with the conventional group. For the ESD expert, there was no significant difference between the mean circumferential resection, submucosal dissection, and total procedure time (prototype group 14.2 ± 6.0 minutes, conventional group 14.2 ± 8.8 minutes; P = .992). The overall perforation and en bloc resection rates were not significantly different between groups. Ex vivo study. In this ex vivo prospective comparison study, there was a technical advantage for the ESD novice with the prototype endoscope that resulted in a shorter procedure time, which was not observed for cases performed by the ESD expert. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  14. Total vaginectomy and urethral lengthening at time of neourethral prelamination in transgender men.

    PubMed

    Medina, Carlos A; Fein, Lydia A; Salgado, Christopher J

    2017-11-29

    For transgender men (TGM), gender-affirmation surgery (GAS) is often the final stage of their gender transition. GAS involves creating a neophallus, typically using tissue remote from the genital region, such as radial forearm free-flap phalloplasty. Essential to this process is vaginectomy. Complexity of vaginal fascial attachments, atrophy due to testosterone use, and need to preserve integrity of the vaginal epithelium for tissue rearrangement add to the intricacy of the procedure during GAS. We designed the technique presented here to minimize complications and contribute to overall success of the phalloplasty procedure. After obtaining approval from the Institutional Review Board, our transgender (TG) database at the University of Miami Hospital was reviewed to identify cases with vaginectomy and urethral elongation performed at the time of radial forearm free-flap phalloplasty prelamination. Surgical technique for posterior vaginectomy and anterior vaginal wall-flap harvest with subsequent urethral lengthening is detailed. Six patients underwent total vaginectomy and urethral elongation at the time of radial forearm free-flap phalloplasty prelamination. Mean estimated blood loss (EBL) was 290 ± 199.4 ml for the vaginectomy and urethral elongation, and no one required transfusion. There were no intraoperative complications (cystotomy, ureteral obstruction, enterotomy, proctotomy, or neurological injury). One patient had a urologic complication (urethral stricture) in the neobulbar urethra. Total vaginectomy and urethral lengthening procedures at the time of GAS are relatively safe procedures, and using the described technique provides excellent tissue for urethral prelamination and a low complication rate in both the short and long term.

  15. Multineuronal vectorization is more efficient than time-segmental vectorization for information extraction from neuronal activities in the inferior temporal cortex.

    PubMed

    Kaneko, Hidekazu; Tamura, Hiroshi; Tate, Shunta; Kawashima, Takahiro; Suzuki, Shinya S; Fujita, Ichiro

    2010-08-01

    In order for patients with disabilities to control assistive devices with their own neural activity, multineuronal spike trains must be efficiently decoded because only limited computational resources can be used to generate prosthetic control signals in portable real-time applications. In this study, we compare the abilities of two vectorizing procedures (multineuronal and time-segmental) to extract information from spike trains during the same total neuron-seconds. In the multineuronal vectorizing procedure, we defined a response vector whose components represented the spike counts of one to five neurons. In the time-segmental vectorizing procedure, a response vector consisted of components representing a neuron's spike counts for one to five time-segment(s) of a response period of 1 s. Spike trains were recorded from neurons in the inferior temporal cortex of monkeys presented with visual stimuli. We examined whether the amount of information of the visual stimuli carried by these neurons differed between the two vectorizing procedures. The amount of information calculated with the multineuronal vectorizing procedure, but not the time-segmental vectorizing procedure, significantly increased with the dimensions of the response vector. We conclude that the multineuronal vectorizing procedure is superior to the time-segmental vectorizing procedure in efficiently extracting information from neuronal signals. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  16. Amniotic Constriction Bands: Secondary Deformities and Their Treatments.

    PubMed

    Drury, Benjamin T; Rayan, Ghazi M

    2018-01-01

    The purpose of this study was to report the surgical treatment experience of patients with amniotic constriction bands (ACB) over a 35-year interval and detail consequential limb deformities with emphasis on hands and upper extremities, along with the nature and frequency of their surgical treatment methods. Fifty-one patients were identified; 26 were males and 25 females. The total number of deformities was listed. The total number of operations, individual procedures, and operations plus procedures that were done for each patient and their frequency were recorded. The total number of operations was 117, and total number of procedures was 341. More procedures were performed on the upper extremity (85%) than the lower extremity (15%). Including the primary deformity ACB, 16 different hand deformities secondary to ACB were encountered. Sixteen different surgical methods for the upper extremity were utilized; a primary procedure for ACB and secondary reconstructions for all secondary deformities. Average age at the time of the first procedure was 9.3 months. The most common procedures performed, in order of frequency, were excision of ACB plus Z-plasty, release of partial syndactyly, release of fenestrated syndactyly, full-thickness skin grafts, resection of digital bony overgrowth from amputation stumps, and deepening of first and other digital web spaces. Many hand and upper extremity deformities secondary to ACB are encountered. Children with ACB may require more than one operation including multiple procedures. Numerous surgical methods of reconstruction for these children's secondary deformities are necessary in addition to the customary primary procedure of excision of ACB and Z-plasty.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ierardi, Anna Maria; Duka, Ejona; Radaelli, Alessandro

    AimTo evaluate the feasibility of image fusion (IF) of pre-procedural arterial-phase CT angiography or MR angiography with intra-procedural fluoroscopy for road-mapping in endovascular treatment of aorto-iliac steno-occlusive disease.Materials and MethodsBetween September and November, 2014, we prospectively evaluated 5 patients with chronic aorto-iliac steno-occlusive disease, who underwent endovascular treatment in the angiography suite. Fusion image road-mapping was performed using angiographic phase CT images or MR images acquired before and intra-procedural unenhanced cone-beam CT. Radiation dose of the procedure, volume of intra-procedural iodinated contrast medium, fluoroscopy time, and overall procedural time were recorded. Reasons for potential fusion imaging inaccuracies were also evaluated.ResultsImagemore » co-registration and fusion guidance were feasible in all procedures. Mean radiation dose of the procedure was 60.21 Gycm2 (range 55.02–63.75 Gycm2). The mean total procedure time was 32.2 min (range 27–38 min). The mean fluoroscopy time was 12 min and 3 s. The mean procedural iodinated contrast material dose was 24 mL (range 20–40 mL).ConclusionsIF gives Interventional Radiologists the opportunity to use new technologies in order to improve outcomes with a significant reduction of contrast media administration.« less

  18. A cost and time analysis of laryngology procedures in the endoscopy suite versus the operating room.

    PubMed

    Hillel, Alexander T; Ochsner, Matthew C; Johns, Michael M; Klein, Adam M

    2016-06-01

    To assess the costs, charges, reimbursement, and efficiency of performing awake laryngology procedures in an endoscopy suite (ES) compared with like procedures performed in the operating room (OR). Retrospective review of billing records. Cost, charges, and reimbursements for the hospital, surgeon, and anesthesiologist were compared between ES injection laryngoplasty and laser excision procedures and matched case controls in the OR. Time spent in 1) the preoperative unit, 2) the operating or endoscopy suite, and 3) recovery unit were compared between OR and ES procedures. Hospital expenses were significantly less for ES procedures when compared to OR procedures. Reimbursement was similar for ES and OR injection laryngoplasty, though greater for OR laser excisions. Net balance (reimbursement-expenses) was greater for ES procedures. A predictive model of payer costs over a 3-year period showed similar costs for ES and OR laser procedures and reduced costs for ES compared to OR injection laryngoplasty. Times spent preoperatively and the procedure were significantly less for ES procedures. For individual laryngology procedures, the ES reduces time and costs compared to the OR, increasing otolaryngologist and hospital efficiency. This reveals cost and time savings of ES injection laryngoplasty, which occurs at a similar frequency as OR injection laryngoplasty. Given the increased frequency for ES laser procedures, total costs are similar for ES and OR laser excision of papilloma, which usually require repeated procedures. When regulated office space is unavailable, endoscopy rooms represent an alternative setting for unsedated laryngology procedures. NA Laryngoscope, 126:1385-1389, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  19. Primary tracheoesophageal puncture and cricopharyngeal myotomy in stapler-assisted total laryngectomy.

    PubMed

    Beswick, D M; Damrose, E J

    2016-07-01

    To evaluate the utility of the hybrid tracheoesophageal puncture procedure in stapler-assisted laryngectomy. Patients who underwent total laryngectomy at a single institution from 2009 to 2015 were reviewed. The interventions assessed were surgical creation of a tracheoesophageal puncture and placement of a voice prosthesis. The outcomes measured included voicing ability and valve failure. Thirty-nine patients underwent total laryngectomy or pharyngolaryngectomy. Of these, nine underwent stapler-assisted laryngectomy; seven of the nine patients underwent concurrent stapler-assisted laryngectomy, cricopharyngeal myotomy and a hybrid tracheoesophageal puncture procedure. These seven patients were the focus of this review. Successful voicing and oral alimentation was achieved in all patients. Mean time to phonation was 30 days (range, 7-77 days) and mean time to first valve change was 90 days (range, 35-117 days). Primary tracheoesophageal puncture with concurrent voice prosthesis placement and cricopharyngeal myotomy is easily performed with stapler-assisted laryngectomy. The hybrid tracheoesophageal puncture procedure is a simple method that enables a single operator to achieve primary tracheoesophageal puncture and valve placement; in addition, it facilitates concurrent cricopharyngeal myotomy.

  20. Utilization of apical vaginal support procedures at time of inpatient hysterectomy performed for benign conditions: a national estimate.

    PubMed

    Ross, Whitney Trotter; Meister, Melanie R; Shepherd, Jonathan P; Olsen, Margaret A; Lowder, Jerry L

    2017-10-01

    Apical vaginal support is considered the keystone of pelvic organ support. Level I evidence supports reestablishment of apical support at time of hysterectomy, regardless of whether the hysterectomy is performed for prolapse. National rates of apical support procedure performance at time of inpatient hysterectomy have not been well described. We sought to estimate trends and factors associated with use of apical support procedures at time of inpatient hysterectomy for benign indications in a large national database. The National (Nationwide) Inpatient Sample was used to identify hysterectomies performed from 2004 through 2013 for benign indications. International Classification of Diseases, Ninth Revision, Clinical Modification codes were used to select both procedures and diagnoses. The primary outcome was performance of an apical support procedure at time of hysterectomy. Descriptive and multivariable analyses were performed. There were 3,509,230 inpatient hysterectomies performed for benign disease from 2004 through 2013. In both nonprolapse and prolapse groups, there was a significant decrease in total number of annual hysterectomies performed over the study period (P < .0001). There were 2,790,652 (79.5%) hysterectomies performed without a diagnosis of prolapse, and an apical support procedure was performed in only 85,879 (3.1%). There was a significant decrease in the proportion of hysterectomies with concurrent apical support procedure (high of 4.0% in 2004 to 2.5% in 2013, P < .0001). In the multivariable logistic regression model, increasing age, hospital type (urban teaching), hospital bed size (large and medium), and hysterectomy type (vaginal and laparoscopically assisted vaginal) were associated with performance of an apical support procedure. During the study period, 718,578 (20.5%) inpatient hysterectomies were performed for prolapse diagnoses and 266,743 (37.1%) included an apical support procedure. There was a significant increase in the proportion of hysterectomies with concurrent apical support procedure (low of 31.3% in 2005 to 49.3% in 2013, P < .0001). In the multivariable logistic regression model, increasing age, hospital type (urban teaching), hospital bed size (medium and large), and hysterectomy type (total laparoscopic and laparoscopic supracervical) were associated with performance of an apical support procedure. This national database study demonstrates that apical support procedures are not routinely performed at time of inpatient hysterectomy regardless of presence of prolapse diagnosis. Educational efforts are needed to increase awareness of the importance of reestablishing apical vaginal support at time of hysterectomy regardless of indication. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Oral versus intravenous premedication for small bowel biopsy in children: effect on procedure and fluoroscopy times.

    PubMed

    Stenhammar, L; Wärngård, O; Lewander, P; Nordvall, M

    1993-01-01

    Oral alimemazine and cisapride, or diazepam and cisapride, or iv midazolam and metoclopramide were given as premedication for small bowel biopsy to three groups of children from a total population of 185 individuals. The biopsy procedures were performed under intermittent fluoroscopy and times for both were recorded. The median biopsy procedure time was significantly shorter in children given iv midazolam and metoclopramide (6 min) compared to those given oral premedication (10 min) (p < 0.001). The median fluoroscopy time was very short in all groups, ranging between 3 and 6 s. It is concluded that iv premedication is superior to oral premedication for small bowel biopsy in children because more effective sedation is obtained.

  2. Reconciling quality and cost: A case study in interventional radiology.

    PubMed

    Zhang, Li; Domröse, Sascha; Mahnken, Andreas

    2015-10-01

    To provide a method to calculate delay cost and examine the relationship between quality and total cost. The total cost including capacity, supply and delay cost for running an interventional radiology suite was calculated. The capacity cost, consisting of labour, lease and overhead costs, was derived based on expenses per unit time. The supply cost was calculated according to actual procedural material use. The delay cost and marginal delay cost derived from queueing models was calculated based on waiting times of inpatients for their procedures. Quality improvement increased patient safety and maintained the outcome. The average daily delay costs were reduced from 1275 € to 294 €, and marginal delay costs from approximately 2000 € to 500 €, respectively. The one-time annual cost saved from the transfer of surgical to radiological procedures was approximately 130,500 €. The yearly delay cost saved was approximately 150,000 €. With increased revenue of 10,000 € in project phase 2, the yearly total cost saved was approximately 290,000 €. Optimal daily capacity of 4.2 procedures was determined. An approach for calculating delay cost toward optimal capacity allocation was presented. An overall quality improvement was achieved at reduced costs. • Improving quality in terms of safety, outcome, efficiency and timeliness reduces cost. • Mismatch of demand and capacity is detrimental to quality and cost. • Full system utilization with random demand results in long waiting periods and increased cost.

  3. A Fast MAC-Layer Handover for an IEEE 802.16e-Based WMAN

    NASA Astrophysics Data System (ADS)

    Ray, Sayan K.; Pawlikowski, Krzysztof; Sirisena, Harsha

    We propose a modification of the IEEE 802.16e hard handover (HHO) procedure, which significantly reduces the handover latency constraint of the original HHO procedure in IEEE 802.16e networks. It allows a better handling of the delay-sensitive traffic by avoiding unnecessary time-consuming scanning and synchronization activity as well as simplifies the network re-entry procedure. With the help of the backhaul network, it reduces the number of control messages in the original handover policy, making the handover latency acceptable also for real-time streaming traffic. Preliminary performance evaluation studies show that the modified handover procedure is able to reduce the total handover latency by about 50%.

  4. Hormonal Changes After Laparoscopic Ovarian Diathermy in Patients with Polycystic Ovarian Syndrome.

    PubMed

    Elnaggar, Elsayed A; Elwan, Youssef Abo; Ibrahim, Safaa A; Abdalla, Mena M

    2016-10-01

    To assess the changes in hormonal profile (serum FSH, LH, prolactin and total testosterone) following laparoscopic ovarian drilling (LOD) in patients with polycystic ovarian syndrome. Fifty patients with PCOS have been included in this study. Serum prolactin, total testosterone, follicular-stimulating hormone (FSH) and luteinizing hormone (LH) levels have been used as biochemical markers, before and after procedures. Laparoscopic ovarian drilling was successfully employed without any surgical complications and on an average follow-up time of 24 weeks after the procedure. During the follow-up serum values for prolactin, total testosterone and LH have decreased significantly and FSH levels remained unchanged after the procedure. The LOD in patients with PCOS may avoid or reduce the risk of OHSS and the multiple pregnancy rate induced by gonadotropin therapy. The high pregnancy rate and the economic aspect of the procedure offer an attractive management for patients with PCOS. However, LOD can be considered as second-line treatment after clomiphene citrate treatment failure and/or resistance.

  5. Predictive Factors of Atelectasis Following Endoscopic Resection.

    PubMed

    Choe, Jung Wan; Jung, Sung Woo; Song, Jong Kyu; Shim, Euddeum; Choo, Ji Yung; Kim, Seung Young; Hyun, Jong Jin; Koo, Ja Seol; Yim, Hyung Joon; Lee, Sang Woo

    2016-01-01

    Atelectasis is one of the pulmonary complications associated with anesthesia. Little is known about atelectasis following endoscopic procedures under deep sedation. This study evaluated the frequency, risk factors, and clinical course of atelectasis after endoscopic resection. A total of 349 patients who underwent endoscopic resection of the upper gastrointestinal tract at a single academic tertiary referral center from March 2010 to October 2013 were enrolled. Baseline characteristics and clinical data were retrospectively reviewed from medical records. To identify atelectasis, we compared the chest radiography taken before and after the endoscopic procedure. Among the 349 patients, 68 (19.5 %) had newly developed atelectasis following endoscopic resection. In univariate logistic regression analysis, atelectasis correlated significantly with high body mass index, smoking, diabetes mellitus, procedure duration, size of lesion, and total amount of propofol. In multiple logistic regression analysis, body mass index, procedure duration, and total propofol amount were risk factors for atelectasis following endoscopic procedures. Of the 68 patients with atelectasis, nine patients developed fever, and six patients displayed pneumonic infiltration. The others had no symptoms related to atelectasis. The incidence of radiographic atelectasis following endoscopic resection was nearly 20 %. Obesity, procedural time, and amount of propofol were the significant risk factors for atelectasis following endoscopic procedure. Most cases of the atelectasis resolved spontaneously with no sequelae.

  6. Electromagnetic navigation reduces surgical time and radiation exposure for proximal interlocking in retrograde femoral nailing.

    PubMed

    Somerson, Jeremy S; Rowley, David; Kennedy, Chad; Buttacavoli, Frank; Agarwal, Animesh

    2014-07-01

    To compare the time required for proximal locking screw placement between a standard freehand technique and the navigated technique, and to quantify the reduction in ionizing radiation exposure. A fresh frozen cadaver model was used for 48 proximal interlocking screw procedures. Each procedure consisted of insertion of 2 anteroposterior locking screws. Standard fluoroscopic technique was used for 24 procedures, and an electromagnetic navigation system was used for the remaining 24 procedures. Procedure duration was recorded using an electronic timer and radiation doses were documented. Mean total insertion time for both proximal interlocking screws was 405 ± 165.7 seconds with the freehand technique and 311 ± 78.3 seconds in the navigation group (P = 0.002). All procedures resulted in successful locking screw placement. Mean ionizing radiation exposure time for proximal locking was 29.5 ± 12.8 seconds. Proximal locking screw insertion using the navigation technique evaluated in this work was significantly faster than the standard fluoroscopic method. The navigated technique is effective and has the potential to prevent ionizing radiation exposure.

  7. 21 CFR 500.26 - Timed-release dosage form drugs.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 201(v) of the Federal Food, Drug, and Cosmetic Act. (b) Timed-release dosage form animal drugs that... using procedures and controls to ensure release of the total dosage at a safe and effective rate. Data...

  8. 21 CFR 500.26 - Timed-release dosage form drugs.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 201(v) of the Federal Food, Drug, and Cosmetic Act. (b) Timed-release dosage form animal drugs that... using procedures and controls to ensure release of the total dosage at a safe and effective rate. Data...

  9. 21 CFR 500.26 - Timed-release dosage form drugs.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 201(v) of the Federal Food, Drug, and Cosmetic Act. (b) Timed-release dosage form animal drugs that... using procedures and controls to ensure release of the total dosage at a safe and effective rate. Data...

  10. 21 CFR 500.26 - Timed-release dosage form drugs.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 201(v) of the Federal Food, Drug, and Cosmetic Act. (b) Timed-release dosage form animal drugs that... using procedures and controls to ensure release of the total dosage at a safe and effective rate. Data...

  11. 21 CFR 500.26 - Timed-release dosage form drugs.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 201(v) of the Federal Food, Drug, and Cosmetic Act. (b) Timed-release dosage form animal drugs that... using procedures and controls to ensure release of the total dosage at a safe and effective rate. Data...

  12. A simple ergonomic measure reduces fluoroscopy time during ERCP: A multivariate analysis.

    PubMed

    Jowhari, Fahd; Hopman, Wilma M; Hookey, Lawrence

    2017-03-01

    Background and study aims  Endoscopic retrograde cholangiopancreatgraphy (ERCP) carries a radiation risk to patients undergoing the procedure and the team performing it. Fluoroscopy time (FT) has been shown to have a linear relationship with radiation exposure during ERCP. Recent modifications to our ERCP suite design were felt to impact fluoroscopy time and ergonomics. This multivariate analysis was therefore undertaken to investigate these effects, and to identify and validate various clinical, procedural and ergonomic factors influencing the total fluoroscopy time during ERCP. This would better assist clinicians with predicting prolonged fluoroscopic durations and to undertake relevant precautions accordingly. Patients and methods  A retrospective analysis of 299 ERCPs performed by 4 endoscopists over an 18-month period, at a single tertiary care center was conducted. All inpatients/outpatients (121 males, 178 females) undergoing ERCP for any clinical indication from January 2012 to June 2013 in the chosen ERCP suite were included in the study. Various predetermined clinical, procedural and ergonomic factors were obtained via chart review. Univariate analyses identified factors to be included in the multivariate regression model with FT as the dependent variable. Results  Bringing the endoscopy and fluoroscopy screens next to each other was associated with a significantly lesser FT than when the screens were separated further (-1.4 min, P  = 0.026). Other significant factors associated with a prolonged FT included having a prior ERCP (+ 1.4 min, P  = 0.031), and more difficult procedures (+ 4.2 min for each level of difficulty, P  < 0.001). ERCPs performed by high-volume endoscopists used lesser FT vs. low-volume endoscopists (-1.82, P = 0.015). Conclusions  Our study has identified and validated various factors that affect the total fluoroscopy time during ERCP. This is the first study to show that decreasing the distance between the endoscopy and fluoroscopy screens in the ERCP suite significantly reduces the total fluoroscopy time, and therefore radiation exposure to patients and staff involved in the procedure.

  13. 40 CFR 62.14452 - What test methods and procedures must I use?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... total dioxin/furan emissions. The minimum sample time must be 4 hours per test run. If you have selected the toxic equivalency standards for dioxin/furans under § 62.14411, you must use the following procedures to determine compliance: (1) Measure the concentration of each dioxin/furan tetra-through octa...

  14. Improved techniques for double-balloon-enteroscopy-assisted endoscopic retrograde cholangiopancreatography

    PubMed Central

    Osoegawa, Takashi; Motomura, Yasuaki; Akahoshi, Kazuya; Higuchi, Naomi; Tanaka, Yoshimasa; Hisano, Terumasa; Itaba, Souichi; Gibo, Junya; Yamada, Mariko; Kubokawa, Masaru; Sumida, Yorinobu; Akiho, Hirotada; Ihara, Eikichi; Nakamura, Kazuhiko

    2012-01-01

    AIM: To investigate the clinical outcome of double balloon enteroscopy (DBE)-assisted endoscopic retrograde cholangiopancreatography (DB-ERCP) in patients with altered gastrointestinal anatomy. METHODS: Between September 2006 and April 2011, 47 procedures of DB-ERCP were performed in 28 patients with a Roux-en-Y total gastrectomy (n = 11), Billroth II gastrectomy (n = 15), or Roux-en-Y anastomosis with hepaticojejunostomy (n = 2). DB-ERCP was performed using a short-type DBE combined with several technical innovations such as using an endoscope attachment, marking by submucosal tattooing, selectively applying contrast medium, and CO2 insufflations. RESULTS: The papilla of Vater or hepaticojejunostomy site was reached in its entirety with a 96% success rate (45/47 procedures). There were no significant differences in the success rate of reaching the blind end with a DBE among Roux-en-Y total gastrectomy (96%), Billroth II reconstruction (94%), or pancreatoduodenectomy (100%), respectively (P = 0.91). The total successful rate of cannulation and contrast enhancement of the target bile duct in patients whom the blind end was reached with a DBE was 40/45 procedures (89%). Again, there were no significant differences in the success rate of cannulation and contrast enhancement of the target bile duct with a DBE among Roux-en-Y total gastrectomy (88 %), Billroth II reconstruction (89%), or pancreatoduodenectomy (100%), respectively (P = 0.67). Treatment was achieved in all 40 procedures (100%) in patients whom the contrast enhancement of the bile duct was successful. Common endoscopic treatments were endoscopic biliary drainage (24 procedures) and extraction of stones (14 procedures). Biliary drainage was done by placement of plastic stents. Stones extraction was done by lithotomy with the mechanical lithotripter followed by extraction with a basket or by the balloon pull-through method. Endoscopic sphincterotomy was performed in 14 procedures with a needle precutting knife using a guidewire. The mean total duration of the procedure was 93.6 ± 6.8 min and the mean time required to reach the papilla was 30.5 ± 3.7 min. The mean time required to reach the papilla tended to be shorter in Billroth II reconstruction (20.9 ± 5.8 min) than that in Roux-en-Y total gastrectomy (37.1 ± 4.9 min) but there was no significant difference (P = 0.09). A major complication occurred in one patient (3.5%); perforation of the long limb in a patient with Billroth II anastomosis. CONCLUSION: Short-type DBE combined with several technical innovations enabled us to perform ERCP in most patients with altered gastrointestinal anatomy. PMID:23239923

  15. Can the learning curve of totally endoscopic robotic mitral valve repair be short-circuited?

    PubMed

    Yaffee, David W; Loulmet, Didier F; Kelly, Lauren A; Ward, Alison F; Ursomanno, Patricia A; Rabinovich, Annette E; Neuburger, Peter J; Krishnan, Sandeep; Hill, Frederick T; Grossi, Eugene A

    2014-01-01

    A concern with the initiation of totally endoscopic robotic mitral valve repair (TERMR) programs has been the risk for the learning curve. To minimize this risk, we initiated a TERMR program with a defined team and structured learning approach before clinical implementation. A dedicated team (two surgeons, one cardiac anesthesiologist, one perfusionist, and two nurses) was trained with clinical scenarios, simulations, wet laboratories, and "expert" observation for 3 months. This team then performed a series of TERMRs of varying complexity. Thirty-two isolated TERMRs were performed during the first programmatic year. All operations included mitral valve repair, left atrial appendage exclusion, and annuloplasty device implantation. Additional procedures included leaflet resection, neochordae insertion, atrial ablation, and papillary muscle shortening. Longer clamp times were associated with number of neochordae (P < 0.01), papillary muscle procedures (P < 0.01), and leaflet resection (P = 0.06). Sequential case number had no impact on cross-clamp time (P = 0.3). Analysis of nonclamp time demonstrated a 71.3% learning percentage (P < 0.01; ie, 28.7% reduction in nonclamp time with each doubling of case number). There were no hospital deaths or incidences of stroke, myocardial infarction, unplanned reoperation, respiratory failure, or renal failure. Median length of stay was 4 days. All patients were discharged home. Totally endoscopic robotic mitral valve repair can be safely performed after a pretraining regimen with emphasis on experts' current practice and team training. After a pretraining regimen, cross-clamp times were not subject to learning curve phenomena but were dependent on procedural complexity. Nonclamp times were associated with a short learning curve.

  16. Initial clinical experience with cardiac resynchronization therapy utilizing a magnetic navigation system.

    PubMed

    Gallagher, Peter; Martin, Laura; Angel, Lori; Tomassoni, Gery

    2007-02-01

    The placement of left ventricular (LV) leads during cardiac resynchronization therapy (CRT) involves many technical difficulties. These difficulties increase procedural times and decrease procedural success rates. A total of 50 patients with severe cardiomyopathy (mean LV ejection fraction was 21 +/- 6%) and a wide QRS underwent CRT implantation. Magnetic navigation (Stereotaxis, Inc.) was used to position a magnet-tipped 0.014'' guidewire (Cronus guidewire) within the coronary sinus (CS) vasculature. LV leads were placed in a lateral CS branch, either using a standard CS delivery sheath or using a "bare-wire" approach without a CS delivery sheath. The mean total procedure time was 98.1 +/- 29.1 minutes with a mean fluoroscopy time of 22.7 +/- 15.1 minutes. The mean LV lead positioning time was 10.4 +/- 7.6 minutes. The use of a delivery sheath was associated with longer procedure times 98 +/- 32 minutes vs 80 +/- 18 minutes (P = 0.029), fluoroscopy times 23 +/- 15 minutes vs 13 +/- 4 minutes (P = 0.0007) and LV lead positioning times 10 +/- 6 minutes vs 4 +/- 2 minutes (P = 0.015) when compared to a "bare-wire" approach. When compared with 52 nonmagnetic-assisted control CRT cases, magnetic navigation reduced total LV lead positioning times (10.4 +/- 7.6 minutes vs 18.6 +/- 18.9 minutes; P = 0.005). If more than one CS branch vessel was tested, magnetic navigation was associated with significantly shorter times for LV lead placement (16.2 +/- 7.7 minutes vs 36.4 +/- 23.4 minutes; P = 0.004). Magnetic navigation is a safe, feasible, and efficient tool for lateral LV lead placement during CRT. Magnetic navigation during CRT allows for control of the tip direction of the Cronus 0.014'' guidewire using either a standard CS delivery sheath or "bare-wire" approach. Although there are some important limitations to the 0.014'' Cronus magnetic navigation can decrease LV lead placement times compared with nonmagnetic-assisted control CRT cases, particularly if multiple CS branches are to be tested.

  17. An improved reference measurement procedure for triglycerides and total glycerides in human serum by isotope dilution gas chromatography-mass spectrometry.

    PubMed

    Chen, Yizhao; Liu, Qinde; Yong, Sharon; Teo, Hui Ling; Lee, Tong Kooi

    2014-01-20

    Triglycerides are widely tested in clinical laboratories using enzymatic methods for lipid profiling. As enzymatic methods can be affected by interferences from biological samples, this together with the non-specific nature of triglycerides measurement makes it necessary to verify the accuracy of the test results with a reference measurement procedure. Several such measurement procedures had been published. These procedures generally involved lengthy and laborious sample preparation steps. In this paper, an improved reference measurement procedure for triglycerides and total glycerides was reported which simplifies the sample preparation steps and greatly shortens the time taken. The procedure was based on isotope dilution gas chromatography-mass spectrometry (IDGC-MS)with tripalmitin as the calibration standard. Serum samples were first spiked with isotope-labeled tripalmitin. For the measurement of triglycerides, the serum samples were subjected to lipid extraction followed by separation of triglycerides from diglycerides and monoglycerides. Triglycerides were then hydrolyzed to glycerol, derivatized and injected into the GC–MS for quantification. For the measurement of total glycerides, the serum samples were hydrolyzed directly and derivatized before injection into the GC-MS for quantification. All measurement results showed good precision with CV <1%. A certified reference material (CRM) of lipids in frozen human serum was used to verify the accuracy of the measurement. The obtained values for both triglycerides and total glycerides were well within the certified ranges of the CRM, with deviation <0.4% from the certified values. The relative expanded uncertainties were also comparable with the uncertainties associated with the certified values of the CRM. The validated procedure was used in an External Quality Assessment (EQA) Program organized by our laboratory to establish the assigned values for triglycerides and total glycerides.

  18. Time process study with UML.

    PubMed

    Shiki, N; Ohno, Y; Fujii, A; Murata, T; Matsumura, Y

    2009-01-01

    We propose a new business-process analysis approach, Time Process Study (TPS), which comprises process analysis and time and motion studies (TMS). TPS offsets weaknesses of TMS; the cost of field studies and the difficulties in applying them to tasks whose time span differs from those of usual tasks. In TPS, the job procedures are first displayed using a unified modeling language (UML). Next, time and manpower for each procedure are studied through interviews and TMS, and the information is appended to the UML diagram. We applied TPS in the case of a hospital-based cancer registry (HCR) of a university hospital to clarify the work procedure and the time required, and investigated TPS's availability. Meetings for the study were held once a month from July to September in 2008, and one inquirer committed a total of eight hours to the hospital survey. TPS revealed that HCR consisted of three tasks and 14 functions. The registration required 123 hours/month/person, the quality control required 6.5 hours/ 6 months/person and filing data into the population-based cancer registry required 0.5 hours/6 months/person. Of the total tasks involved in registration, 116.5 hours/month/person were undertaken by a registration worker, which shows the necessity of employing one full-time staff. With TPS, it is straightforward to share the concept among the study-team because the job procedure is first displayed using UML. Therefore, it requires a few workload to conduct TMS and interview. The obtained results were adopted for the review of staff assignment of HCR by Japanese government.

  19. Trends of Concurrent Ankle Arthroscopy at the Time of Operative Treatment of Ankle Fracture: A National Database Review.

    PubMed

    Ackermann, Jakob; Fraser, Ethan J; Murawski, Christopher D; Desai, Payal; Vig, Khushdeep; Kennedy, John G

    2016-04-01

    The purpose of this study was to report trends associated with concurrent ankle arthroscopy at the time of operative treatment of ankle fracture. The current procedural terminology (CPT) billing codes were used to search the PearlDiver Patient Record Database and identify all patients who were treated for acute ankle fracture in the United States. The Medicare Standard Analytic Files were searchable between 2005 and 2011 and the United Healthcare Orthopedic Dataset from 2007 to 2011. Annual trends were expressed only between 2007 and 2011, as it was the common time period among both databases. Demographic factors were identified for all procedures as well as the cost aspect using the Medicare data set. In total, 32 307 patients underwent open reduction internal fixation (ORIF) of an ankle fracture, of whom 313 (1.0%) had an ankle arthroscopy performed simultaneously. Of those 313 cases, 70 (22.4%) patients received microfracture treatment. Between 2005 and 2011, 85 203 patients were treated for an ankle fracture whether via ORIF or closed treatment. Of these, a total of 566 patients underwent arthroscopic treatment within 7 years. The prevalence of arthroscopy after ankle fracture decreased significantly by 45% from 2007 to 2011 (P< .0001). When ORIF and microfracture were performed concurrently, the total average charge for both procedures drops to $4253.00 and average reimbursement to $818.00 compared with approximately $4964.00 and $1069.00, respectively, when they were performed subsequently. Despite good evidence in favor of arthroscopy at the time of ankle fracture treatment, it appears that only a small proportion of surgeons in the United States perform these procedures concurrently. Therapeutic, Level IV: Retrospective. © 2015 The Author(s).

  20. A transition from using multi‐step procedures to a fully integrated system for performing extracorporeal photopheresis: A comparison of costs and efficiencies

    PubMed Central

    Leblond, Veronique; Ouzegdouh, Maya; Button, Paul

    2017-01-01

    Abstract Introduction The Pitié Salpêtrière Hospital Hemobiotherapy Department, Paris, France, has been providing extracorporeal photopheresis (ECP) since November 2011, and started using the Therakos® CELLEX® fully integrated system in 2012. This report summarizes our single‐center experience of transitioning from the use of multi‐step ECP procedures to the fully integrated ECP system, considering the capacity and cost implications. Materials and Methods The total number of ECP procedures performed 2011–2015 was derived from department records. The time taken to complete a single ECP treatment using a multi‐step technique and the fully integrated system at our department was assessed. Resource costs (2014€) were obtained for materials and calculated for personnel time required. Time‐driven activity‐based costing methods were applied to provide a cost comparison. Results The number of ECP treatments per year increased from 225 (2012) to 727 (2015). The single multi‐step procedure took 270 min compared to 120 min for the fully integrated system. The total calculated per‐session cost of performing ECP using the multi‐step procedure was greater than with the CELLEX® system (€1,429.37 and €1,264.70 per treatment, respectively). Conclusions For hospitals considering a transition from multi‐step procedures to fully integrated methods for ECP where cost may be a barrier, time‐driven activity‐based costing should be utilized to gain a more comprehensive understanding the full benefit that such a transition offers. The example from our department confirmed that there were not just cost and time savings, but that the time efficiencies gained with CELLEX® allow for more patient treatments per year. PMID:28419561

  1. The costs and quality of operative training for residents in tympanoplasty type I.

    PubMed

    Wang, Mao-Che; Yu, Eric Chen-Hua; Shiao, An-Suey; Liao, Wen-Huei; Liu, Chia-Yu

    2009-05-01

    A teaching hospital would incur more operation room costs on training surgical residents. To evaluate the increased operation time and the increased operation room costs of operations performed by surgical residents. As a model we used a very common surgical otology procedure -- tympanoplasty type I. From January 1, 2004 to December 31, 2004, we included in this study 100 patients who received tympanoplasty type I in Taipei Veterans General Hospital. Fifty-six procedures were performed by a single board-certified surgeon and 44 procedures were performed by residents. We analyzed the operation time and surgical outcomes in these two groups of patients. The operation room cost per minute was obtained by dividing the total operation room expenses by total operation time in the year 2004. The average operation time of residents was 116.47 min, which was significantly longer (p<0.0001) than that of the board-certified surgeon (average 81.07 min). It cost USD $40.36 more for each operation performed by residents in terms of operation room costs. The surgical success rate of residents was 81.82%, which was significantly lower (p=0.016) than that of the board-certified surgeon (96.43%).

  2. Surgeon and hospital cost variability for septoplasty and inferior turbinate reduction.

    PubMed

    Thomas, Andrew; Alt, Jeremiah; Gale, Craig; Vijayakumar, Sathya; Padia, Reema; Peters, Matthew; Champagne, Trevor; Meier, Jeremy D

    2016-10-01

    Septoplasty and turbinate reduction (STR) is a common procedure for which cost reduction efforts may improve value. The purpose of this study was to identify sources of variation in medical facility and surgeon costs associated with STR, and whether these costs correlated with short-term complications. An observational cohort study was performed in a multifacility network using a standardized cost-accounting system to determine costs associated with adult STR from January 1, 2008 to July 31, 2015. A total of 4007 cases, performed at 21 facilities, by 72 different surgeons were included in the study. Total costs, variable costs, operating room (OR) time, and 30-day complications (eg, epistaxis) were compared among surgeons, facilities, and specialties. Total procedure cost: (mean ± standard deviation [SD]) $2503 ± $790 (range, $852 to $10,559). Mean total variable cost: $1147 ± $423 (range, $400 to $5,081). Intersurgeon and interfacility variability was significant for total cost (p < 0.0001) and OR time (p < 0.0001). Intersurgeon OR supply cost variability was also significant (p < 0.0001). Otolaryngologists had less total cost (p < 0.0001), OR time/cost (p < 0.0001), and complications (p = 0.0164), but greater supply cost (p < 0.0001), than other specialties. There is wide variation in cost associated with STR. Significant variance in OR time and supply cost between surgeons suggests these are potential areas for cost reduction. Although no increased 30-day complications were seen with faster and less costly surgeries, further research is needed to evaluate how time and cost relate to quality of care. © 2016 ARS-AAOA, LLC.

  3. "Low-field" intraoperative MRI: a new scenario, a new adaptation.

    PubMed

    Iturri-Clavero, F; Galbarriatu-Gutierrez, L; Gonzalez-Uriarte, A; Tamayo-Medel, G; de Orte, K; Martinez-Ruiz, A; Castellon-Larios, K; Bergese, S D

    2016-11-01

    To describe the adaptation of Cruces University Hospital to the use of intraoperative magnetic resonance imaging (ioMRI), and how the acquisition and use of this technology would impact the day-to-day running of the neurosurgical suite. With the approval of the ethics committee, an observational, prospective study was performed from June 2012 to April 2014, which included 109 neurosurgical procedures with the assistance of ioMRI. These were performed using the Polestar N-30 system (PSN30; Medtronic Navigation, Louisville, CO), which was integrated into the operating room. A total of 159 procedures were included: 109 cranial surgeries assisted with ioMRI and 50 control cases (no ioMRI use). There were no statistical significant differences when anaesthetic time (p=0.587) and surgical time (p=0.792) were compared; however, an important difference was shown in duration of patient positioning (p<0.0009) and total duration of the procedure (p<0.0009) between both groups. The introduction of ioMRI is necessary for most neurosurgical suites; however, a few things need to be taken into consideration when adapting to it. Increase procedure time, the use of specific MRI-safe devices, as well as a checklist for each patient to minimise risks, should be taken into consideration. Published by Elsevier Ltd.

  4. Relative value of dental procedures.

    PubMed

    Tuominen, R; Tuominen, M

    1994-10-01

    This study was conducted to develop a relative value method for dental procedures, and to evaluate the differences in values assigned by private and public sector dentists. Samples of 90 general practitioners and 120 clinical specialists were systematically drawn to represent all actively working Finnish dentists. The dentists were asked to assess the required time and know-how for performing various procedures compared to performing a two-surface amalgam filling (AF2). At the end, the dentists were asked to divide the value of 200 between time and know-how for the reference procedure (AF2). These figures were then utilized to calculate the average relative value for each procedure. Private practitioners' weighted relative values were 55.3% higher than the prices, and among public sector dentists they were 27.9% higher. Overall, know-how constituted more of the total value of the procedures than did time. Private practitioners' time assessments correlated well (r = 0.72-0.95) with the recommended prices. However, significant differences were often observed both in time and know-how assessments of individual procedures. Both time and know-how seem to be important factors when determining values for dental services. For evaluation of the value of output in the private sector, the use of prices is justified. However, when the productivity of non-profit dental offices is evaluated, a value system which is not based on market prices is needed.

  5. A computational procedure for multibody systems including flexible beam dynamics

    NASA Technical Reports Server (NTRS)

    Downer, J. D.; Park, K. C.; Chiou, J. C.

    1990-01-01

    A computational procedure suitable for the solution of equations of motions for flexible multibody systems has been developed. The flexible beams are modeled using a fully nonlinear theory which accounts for both finite rotations and large deformations. The present formulation incorporates physical measures of conjugate Cauchy stress and covariant strain increments. As a consequence, the beam model can easily be interfaced with real-time strain measurements and feedback control systems. A distinct feature of the present work is the computational preservation of total energy for undamped systems; this is obtained via an objective strain increment/stress update procedure combined with an energy-conserving time integration algorithm which contains an accurate update of angular orientations. The procedure is demonstrated via several example problems.

  6. Single-Port Surgery: Laboratory Experience with the daVinci Single-Site Platform

    PubMed Central

    Haber, Georges-Pascal; Kaouk, Jihad; Kroh, Matthew; Chalikonda, Sricharan; Falcone, Tommaso

    2011-01-01

    Background and Objectives: The purpose of this study was to evaluate the feasibility and validity of a dedicated da Vinci single-port platform in the porcine model in the performance of gynecologic surgery. Methods: This pilot study was conducted in 4 female pigs. All pigs had a general anesthetic and were placed in the supine and flank position. A 2-cm umbilical incision was made, through which a robotic single-port device was placed and pneumoperitoneum obtained. A data set was collected for each procedure and included port placement time, docking time, operative time, blood loss, and complications. Operative times were compared between cases and procedures by use of the Student t test. Results: A total of 28 surgical procedures (8 oophorectomies, 4 hysterectomies, 8 pelvic lymph node dissections, 4 aorto-caval nodal dissections, 2 bladder repairs, 1 uterine horn anastomosis, and 1 radical cystectomy) were performed. There was no statistically significant difference in operating times for symmetrical procedures among animals (P=0.3215). Conclusions: This animal study demonstrates that single-port robotic surgery using a dedicated single-site platform allows performing technically challenging procedures within acceptable operative times and without complications or insertion of additional trocars. PMID:21902962

  7. Early Australian experience in robotic sleeve gastrectomy: a single site series.

    PubMed

    Silverman, Candice D; Ghusn, Michael A

    2017-05-01

    The use of robotic platforms in bariatric surgery has recently gained relevance. With an increased use of this technology come concerns regarding learning curve effects during the initial implementation phase. The sleeve gastrectomy though may represent an ideal training procedure for introducing the robot into bariatric surgical practice. The present review of the first 10 consecutive robotic sleeve gastrectomy procedures performed in an Australian bariatric programme by a single surgeon describes the evolution of the technique, learning curve and initial patient outcomes. Between 2014 and 2015, robotic sleeve gastrectomies were performed as primary and revisional procedures by a consistent surgeon-assistant team. Technique evolution and theatre set-up were documented. Patient demographics, operative time (robot docking and total operation time), additional operative procedures performed, operative and post-operative complications at 1, 3 and 6 months post-procedure and weight loss achieved at 6 months were retrospectively reviewed from a prospectively maintained database. Ten robotic sleeve gastrectomies were performed without significant operative complications. One patient was treated as an outpatient with oral antibiotics for a superficial wound infection. The median total operative time was 123 min (interquartile range (IQR) 108.8-142.5), with a median incision to docking time of 19 min (IQR 15.0-31.8). Length of stay in hospital was 2-3 days. Median excess weight loss achieved at 6 months was 50% (IQR 33.9-66.5). This study describes a method of safely introducing the da Vinci robot into bariatric surgical practice. © 2016 Royal Australasian College of Surgeons.

  8. Increased anaesthesia duration increases venous thromboembolism risk in plastic surgery: A 6-year analysis of over 19,000 cases using the NSQIP dataset.

    PubMed

    Mlodinow, Alexei S; Khavanin, Nima; Ver Halen, Jon P; Rambachan, Aksharananda; Gutowski, Karol A; Kim, John Y S

    2015-01-01

    Venous thromboembolism (VTE) is a significant cause of morbidity and mortality, particularly in the postoperative setting. Various risk stratification schema exist in the plastic surgery literature, but do not take into account variations in procedure length. The putative risk of VTE conferred by increased length of time under anaesthesia has never been rigorously explored. The goal of this study is to assess this relationship and to benchmark VTE rates in plastic surgery. A large, multi-institutional quality-improvement database was queried for plastic and reconstructive surgery procedures performed under general anaesthesia between 2005-2011. In total, 19,276 cases were abstracted from the database. Z-scores were calculated based on procedure-specific mean surgical durations, to assess each case's length in comparison to the mean for that procedure. A total of 70 patients (0.36%) experienced a post-operative VTE. Patients with and without post-operative VTE were compared with respect to a variety of demographics, comorbidities, and intraoperative characteristics. Potential confounders for VTE were included in a regression model, along with the Z-scores. VTE occurred in both cosmetic and reconstructive procedures. Longer surgery time, relative to procedural means, was associated with increased VTE rates. Further, regression analysis showed increase in Z-score to be an independent risk factor for post-operative VTE (Odds Ratio of 1.772 per unit, p-value < 0.001). Subgroup analyses corroborated these findings. This study validates the long-held view that increased surgical duration confers risk of VTE, as well as benchmarks VTE rates in plastic surgery procedures. While this in itself does not suggest an intervention, surgical time under general anaesthesia would be a useful addition to existing risk models in plastic surgery.

  9. Reducing costs while maintaining quality in endovascular neurosurgical procedures.

    PubMed

    Kashlan, Osama N; Wilson, Thomas J; Chaudhary, Neeraj; Gemmete, Joseph J; Stetler, William R; Dunnick, N Reed; Thompson, B Gregory; Pandey, Aditya S

    2014-11-01

    As medical costs continue to rise during a time of increasing medical resource utilization, both hospitals and physicians must attempt to limit superfluous health care expenses. Neurointerventional treatment has been shown to be costly, but it is often the best treatment available for certain neuropathologies. The authors studied the effects of 3 policy changes designed to limit the costs of performing neurointerventional procedures at the University of Michigan. The authors retrospectively analyzed the costs of performing neurointerventional procedures during the 6-month periods before and after the implementation of 3 cost-saving policies: 1) the use of an alternative, more economical contrast agent, 2) standardization of coil prices through negotiation with industry representatives to receive economies of scale, and 3) institution of a feedback method to show practitioners the costs of unused products per patient procedure. The costs during the 6-month time intervals before and after implementation were also compared with costs during the most recent 6-month time period. The policy requiring use of a more economical contrast agent led to a decrease in the cost of contrast usage of $42.79 per procedure for the first 6 months after implementation, and $137.09 per procedure for the most current 6-month period, resulting in an estimated total savings of $62,924.31 for the most recent 6-month period. The standardized coil pricing system led to savings of $159.21 per coil after the policy change, and $188.07 per coil in the most recent 6-month period. This yielded total estimated savings of $76,732.56 during the most recent 6-month period. The feedback system for unused items decreased the cost of wasted products by approximately $44.36 per procedure in the 6 months directly after the policy change and by $48.20 per procedure in the most recent 6-month period, leading to total estimated savings of $22,123.80 during the most recent 6-month period. According to extrapolation over a 1-year period, the 3 policy changes decreased costs by an estimated $323,561.34. Simple cost-saving policies can lead to substantial reductions in costs of neurointerventional procedures while maintaining high levels of quality and growth of services.

  10. Minilaparotomy with a gasless laparoscopic-assisted procedure by abdominal wall lifting for ileorectal anastomosis in patients with slow transit constipation.

    PubMed

    Tomita, Ryouichi; Fujisak, Shigeru

    2009-01-01

    Total colectomy with ileorectal anastomosis (IRA) is the most widely adopted procedure. The aim of this study was to introduce a minimally invasive procedure, i.e., minilaparotomy with laparoscopic-assisted procedure, by abdominal wall lifting for IRA in patients with slow transit constipation (STC). Six STC patients (6 women, aged 40-69 years, mean age 56.3 years) underwent minilaparotomy with gasless laparoscopic-assisted approach by abdominal wall lifting for IRA. The present procedure involved a 7-cm lower abdominal median incision made at the beginning of the operation. 12 mm ports were also placed in the right and left upper abdominal quadrant positions. The upper abdominal wall was lifted by a subcutaneous Kirshner wire. The small wound was pulled upward and/or laterally by retractors (abdominal lifting) and conventional surgical instruments were used through the wound. Occasionally laparoscopic assistance was employed. The terminal ileum with total colon was brought out through the small wound and transected, approximately 5 cm from the ileocecal valve. The colon was also resected at the level of promontrium. Then, IRA was performed in the instruments. The total surgical time was 197.7 +/- 33.9 min and the mean estimated blood loss was 176.8 +/- 42.2 ml. There was no surgical mortality. Post-operative hospitalization was 8.1 +/- 2.1 days. Six months after surgery, they defecated 1.8 +/- 2.1 times daily, have no abdominal distension, pain, and incontinence. The patients also take no laxatives. All subjects were satisfied with this procedure. Minilaparotomy with gasless laparoscopic-assisted IRA by abdominal wall lifting could be a safe and efficient technique in the treatment of STC.

  11. Trends in Medicare Reimbursement for Orthopedic Procedures: 2000 to 2016.

    PubMed

    Eltorai, Adam E M; Durand, Wesley M; Haglin, Jack M; Rubin, Lee E; Weiss, Arnold-Peter C; Daniels, Alan H

    2018-03-01

    Understanding trends in reimbursement is critical to the financial sustainability of orthopedic practices. Little research has examined physician fee trends over time for orthopedic procedures. This study evaluated trends in Medicare reimbursements for orthopedic surgical procedures. The Medicare Physician Fee Schedule was examined for Current Procedural Terminology code values for the most common orthopedic and nonorthopedic procedures between 2000 and 2016. Prices were adjusted for inflation to 2016-dollar values. To assess mean growth rate for each procedure and subspecialty, compound annual growth rates were calculated. Year-to-year dollar amount changes were calculated for each procedure and subspecialty. Reimbursement trends for individual procedures and across subspecialties were compared. Between 2000 and 2016, annual reimbursements decreased for all orthopedic procedures examined except removal of orthopedic implant. The orthopedic procedures with the greatest mean annual decreases in reimbursement were shoulder arthroscopy/decompression, total knee replacement, and total hip replacement. The orthopedic procedures with the least annual reimbursement decreases were carpal tunnel release and repair of ankle fracture. Rate of Medicare procedure reimbursement change varied between subspecialties. Trauma had the smallest decrease in annual change compared with spine, sports, and hand. Annual reimbursement decreased at a significantly greater rate for adult reconstruction procedures than for any of the other subspecialties. These findings indicate that reimbursement for procedures has steadily decreased, with the most rapid decrease seen in adult reconstruction. [Orthopedics. 2018; 41(2):95-102.]. Copyright 2018, SLACK Incorporated.

  12. Procedural and Early Outcomes of Two Re-entry Devices for Subintimal Recanalization of Aortoiliac and Femoropopliteal Chronic Total Occlusions.

    PubMed

    Vuruskan, Ertan; Saracoglu, Erhan

    2017-01-01

    Subintimal angioplasty is a common treatment choice for chronic total occlusions (CTO) in the iliac and femoropopliteal arteries. This article describes the technical aspects and early outcomes of two different re-entry devices and comparison with manual re-entry technique. A retrospective review of 61 patients (re-entry group) treated with Outback or Pioneer Plus catheters was carried out. A matched cohort of patients (n=62) who underwent lower extremity interventions without the use of re-entry devices (manual re-entry group) were also analyzed (overall 123 patients were analyzed). Procedural success, procedural durations, patency estimates, ankle-brachial indices, and complications were analyzed. Sixty-one patients underwent Outback or Pioneer Plus guided subintimal recanalization. After the procedure, ankle-brachial indices significantly increased in all patients during follow-up. Primary patency for the entire cohort was 83% in the first month. When the re-entry device group was compared with manual re-entry group, no difference was found with respect to success, complication, and patencies between the two groups during follow-up. However, procedure duration and the amount of contrast agent used was significantly decreased in re-entry groups (p<0.001). Also, re-entry time was significantly decreased in Pioneer plus group according to Outback group (p<0.001). Recanalization of CTO using re-entry devices for aortoiliac or femoropopliteal arteries is safe and effective. These devices shorten the procedure time, the re-entry time, reduce radiation risk, and reduce the amount of contrast agent employed.

  13. Effect of portal access system and surgery type on surgery times during laparoscopic ovariectomy and salpingectomy in captive African lions and cheetahs.

    PubMed

    Hartman, Marthinus Jacobus; Monnet, Eric; Kirberger, Robert Murco; Schoeman, Johan Petrus

    2016-03-02

    A prospective randomized study was used to compare surgery times for laparoscopic ovariectomy and salpingectomy in female African lion (Panthera leo) (n = 14) and cheetah (Acinonyx jubatus) (n = 20) and to compare the use of a multiple portal access system (MPAS) and single portal access system (SPAS) between groups. Two different portal techniques were used, namely MPAS (three separate ports) in lions and SPAS (SILS™ port) in cheetahs, using standard straight laparoscopic instruments. Portal access system and first ovary was not randomized. Five different surgery times were compared for the two different procedures as well as evaluating the use and application of MPAS and SPAS. Carbon dioxide volumes for lions were recorded. In adult lionesses operative time (OPT) (P = 0.016) and total surgical time (TST) (P = 0.032) were significantly shorter for salpingectomy compared to ovariectomy. Similarly in cheetahs OPT (P = 0.001) and TST (P = 0.005) were also shorter for salpingectomy compared to ovariectomy. In contrast, in lion cubs no difference was found in surgery times for ovariectomy and salpingectomy. Total unilateral procedure time was shorter than the respective bilateral time for both procedures (P = 0.019 and P = 0.001) respectively and unilateral salpingectomy was also faster than unilateral ovariectomy (P = 0.035) in cheetahs. Port placement time, suturing time and TST were significantly shorter for SPAS compared to MPAS (P = 0.008). There was, however, no difference in OPT between SPAS and MPAS. Instrument cluttering with SPAS was found to be negligible. There was no difference in mean volume CO2 required to complete ovariectomy in lions but the correlation between bodyweight and total volume of CO2 in lions was significant (rs = 0.867; P = 0.002). Laparoscopic salpingectomy was faster than ovariectomy in both adult lions and cheetahs. Using SPAS, both unilateral procedures were faster than bilateral procedures in cheetahs. Placement and suturing of SPAS in cheetahs was easier and faster compared to three separate ports in lions and lion cubs. The use of standard straight instruments during SPAS did not prolong surgery. Surgery was faster in cubs and CO2 required for laparoscopic sterilization in lions could be determined. Predictable surgery times and CO2 volumes will facilitate the accurate planning and execution of surgery in lions and cheetahs.

  14. Intravascular US-Guided Portal Vein Access: Improved Procedural Metrics during TIPS Creation.

    PubMed

    Gipson, Matthew G; Smith, Mitchell T; Durham, Janette D; Brown, Anthony; Johnson, Thor; Ray, Charles E; Gupta, Rajan K; Kondo, Kimi L; Rochon, Paul J; Ryu, Robert K

    2016-08-01

    To evaluate transjugular intrahepatic portosystemic shunt (TIPS) outcomes and procedure metrics with the use of three different image guidance techniques for portal vein (PV) access during TIPS creation. A retrospective review of consecutive patients who underwent TIPS procedures for a range of indications during a 28-month study period identified a population of 68 patients. This was stratified by PV access techniques: fluoroscopic guidance with or without portography (n = 26), PV marker wire guidance (n = 18), or intravascular ultrasound (US) guidance (n = 24). Procedural outcomes and procedural metrics, including radiation exposure, contrast agent volume used, procedure duration, and PV access time, were analyzed. No differences in demographic or procedural characteristics were found among the three groups. Technical success, technical success of the primary planned approach, hemodynamic success, portosystemic gradient, and procedure-related complications were not significantly different among groups. Fluoroscopy time (P = .003), air kerma (P = .01), contrast agent volume (P = .003), and total procedural time (P = .02) were reduced with intravascular US guidance compared with fluoroscopic guidance. Fluoroscopy time (P = .01) and contrast agent volume (P = .02) were reduced with intravascular US guidance compared with marker wire guidance. Intravascular US guidance of PV access during TIPS creation not only facilitates successful TIPS creation in patients with challenging anatomy, as suggested by previous investigations, but also reduces important procedure metrics including radiation exposure, contrast agent volume, and overall procedure duration compared with fluoroscopically guided TIPS creation. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  15. Radiation exposure in transcatheter patent ductus arteriosus closure: time to tune?

    PubMed

    Villemain, Olivier; Malekzadeh-Milani, Sophie; Sitefane, Fidelio; Mostefa-Kara, Meriem; Boudjemline, Younes

    2018-05-01

    The aims of this study were to describe radiation level at our institution during transcatheter patent ductus arteriosus occlusion and to evaluate the components contributing to radiation exposure. Transcatheter occlusion relying on X-ray imaging has become the treatment of choice for patients with patent ductus arteriosus. Interventionists now work hard to minimise radiation exposure in order to reduce risk of induced cancers. We retrospectively reviewed all consecutive children who underwent transcatheter closure of patent ductus arteriosus from January 2012 to January 2016. Clinical data, anatomical characteristics, and catheterisation procedure parameters were reported. Radiation doses were analysed for the following variables: total air kerma, mGy; dose area product, Gy.cm2; dose area product per body weight, Gy.cm2/kg; and total fluoroscopic time. A total of 324 patients were included (median age=1.51 [Q1-Q3: 0.62-4.23] years; weight=10.3 [6.7-17.0] kg). In all, 322/324 (99.4%) procedures were successful. The median radiation doses were as follows: total air kerma: 26 (14.5-49.3) mGy; dose area product: 1.01 (0.56-2.24) Gy.cm2; dose area product/kg: 0.106 (0.061-0.185) Gy.cm2/kg; and fluoroscopic time: 2.8 (2-4) min. In multivariate analysis, a weight >10 kg, a ductus arteriosus width <2 mm, complications during the procedure, and a high frame rate (15 frames/second) were risk factors for an increased exposure. Lower doses of radiation can be achieved with subsequent recommendations: technical improvement, frame rate reduction, avoidance of biplane cineangiograms, use of stored fluoroscopy as much as possible, and limitation of fluoroscopic time. A greater use of echocardiography might even lessen the exposure.

  16. Cost awareness decreases total percutaneous coronary intervention procedural cost: The SHOPPING (Show How Options in Price for Procedures Can Be Influenced Greatly) trial.

    PubMed

    Asher, Elad; Mansour, John; Wheeler, Adam; Kendrick, Daniel; Cunningham, Michael; Parikh, Sahil; Zidar, David; Harford, Todd; Simon, Daniel I; Kashyap, Vikram S

    2017-06-01

    We initiated the SHOPPING Trial (Show How Options in Price for Procedures can be InflueNced Greatly) to see if percutaneous coronary intervention (PCI) procedures can be performed at a lower cost in a single institution. Procedural practice variability is associated with inefficiency and increased cost. We hypothesized that announcing costs for all supplies during a catheterization procedure and reporting individual operator cost relative to peers would spur cost reduction without affecting clinical outcomes. Baseline costs of 10 consecutive PCI procedures performed by 9 interventional cardiologists were documented during a 90-day interval. Costs were reassessed after instituting cost announcing and peer reporting the next quarter. The intervention involved labeling of all endovascular supplies, equipment, devices, and disposables in the catheterization laboratory and announcement of the unit price for each piece when requested. For each interventionalist, procedure time and costs were measured and analyzed prior to and after the intervention. We found that total PCI procedural cost was significantly reduced by an average of $234.77 (P = 0.01), equating to a total savings of $21,129.30 over the course of 90 PCI procedures. Major Adverse Cardiac and Cerebrovascular Event (MACCE) rates were similar during both periods (2.3% vs. 3.5%, P = NS). Announcing costs in the catheterization laboratory during single vessel PCI and peer reporting leads to cost reduction without affecting clinical outcomes. This intervention may have a role in more complex coronary and peripheral interventional procedures, and in other procedural areas where multiple equipment and device alternatives with variable costs are available. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  17. Technical Feasibility of Enterotomy Closure with Knotless Barbed Suture Material (V-Loc 180) in Esophagojejunostomy Using Linear Stapler during Totally Laparoscopic Total Gastrectomy for Gastric Cancer.

    PubMed

    Kim, Dong Jin; Kim, Wook; Lee, Jun Hyun

    2017-08-01

    Intra-corporeal esophagojejunostomy (EJ) using a linear stapler creates a stapler entry hole that requires secure closure during the totally laparoscopic total gastrectomy (TLTG) procedure for gastric cancer. Since a standard method has not been established yet, the feasibility of using V-loc 180 (Covidien, Mansfield, MA, USA) suture material was evaluated in this study. During January 2012 to March 2015, 25 patients who underwent linear stapling EJ and V-loc 180 closure of remaining enterotomy were included in this study. Basic clinico-pathological characteristics, surgical outcomes, and short-term complications were analyzed. The mean patient age was 60.4 ± 8.5 years. Nineteen males and six females were included in this study. The mean body mass index was 25.3 ± 2.3 kg/m 2 . There were 22 stage-I, 2 stage-II, and 1 stage-III gastric cancer patients. The mean operation time was 240.5 ± 44.6 min, and the time for anastomosis was 38.8 ± 11.2 min. The procedures were successfully performed in all cases without any intra-operative complications. There was one case of EJ leakage that occurred at the corner of EJ staple line and not at the enterotomy closure site. The closure of the remaining enterotomy site using V-loc 180 suture following linear stapler EJ is technically feasible and safe during the TLTG procedure. However, further experience and results from other surgeons are necessary to generalize this procedure.

  18. Glove Perforations During Interventional Radiological Procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leena, R. V., E-mail: leenarv_76@yahoo.co.uk; Shyamkumar, N. K.

    2010-04-15

    Intact surgical gloves are essential to avoid contact with blood and other body fluids. The objective of this study was to estimate the incidence of glove perforations during interventional radiological procedures. In this study, a total of 758 gloves used in 94 interventional radiological procedures were examined for perforations. Eleven perforations were encountered, only one of which was of occult type. No significant difference in the frequency of glove perforation was found between the categories with varying time duration.

  19. Lower facial reanimation techniques following cancer resection and free flap reconstruction.

    PubMed

    Kejner, Alexandra E; Rosenthal, Eben L

    2016-09-01

    Evaluate outcomes of the standard static sling and orthodromic temporalis tendon transfer reanimation for facial nerve paralysis. Retrospective case series at a tertiary care hospital of head and neck cancer patients with facial nerve palsy secondary to malignancy or resection. From 2004 to 2014, patients undergoing resection of malignancy that involved facial nerve palsy requiring facial reanimation were identified. All procedures were performed by the senior author (e.l.r.). Demographics, methods, revision rates, combination with other procedures, and complications were evaluated. A total of 77 patients underwent 92 procedures, with two patients requiring more than one revision, for a total of 20 revisions. Average time to revision was 9 months. Age, sex, race, side of repair, paralysis prior to procedure, sling type or method, timing of procedure, and radiation therapy were not significantly different between those requiring revision and those who did not. There was no difference in complications between patients who received radiation and those who did not (P = .5), nor between static versus orthodromic temporalis muscle transfer (P = .5). Complication rate was low at 5.4%. Sling procedures can be successfully performed in patients with facial nerve palsy secondary to cancer resection with radiation therapy, with a low revision rate and few complications. 4 Laryngoscope, 126:1990-1994, 2016. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  20. A study on the efficacy and safety of combining dental surgery with tonsillectomy in pediatrics

    PubMed Central

    Syed, Faizaan; Uffman, Joshua C; Tumin, Dmitry; Flaitz, Catherine M; Tobias, Joseph D; Raman, Vidya T

    2018-01-01

    Purpose Few data exist on combining pediatric surgical procedures under a single general anesthetic encounter (general anesthesia). We compared perioperative outcomes of combining dental surgical procedures with tonsillectomy during one anesthetic vs separate encounters. Methods We classified elective tonsillectomy ± adenoidectomy and restorative dentistry as combined (group C) or separate (group S). Outcomes included anesthesia time, recovery duration, the need for overnight hospital stay, and postoperative complications. Results Patients aged 4±1 years underwent tonsillectomy and dental surgery in combination (n=7) or separately (n=27). No differences were noted in total anesthesia time (C: median: 150, interquartile range [IQR]: 99, 165 vs S: median: 109, IQR: 92, 132; 95% CI of difference in median: −58, +10 minutes; P=0.115) and total recovery time (C: median: 54, IQR: 40, 108 vs S: median: 72, IQR: 58, 109; 95% CI of difference in median: −16, +48 minutes; P=0.307). The need for overnight stay (C: 4 of 7, S: 20 of 27; P=0.394) did not differ between the groups. No postoperative complications were noted in either group. Conclusion These preliminary data support the potential feasibility of combining dental procedures with tonsillectomy during a single anesthetic encounter. Such care may not only reduce costs but also limit parental work absences and increase convenience for patient families. When compared with procedures performed separately, combined procedures did not result in increased morbidity or significant changes in postoperative outcomes. PMID:29628777

  1. A study on the efficacy and safety of combining dental surgery with tonsillectomy in pediatrics.

    PubMed

    Syed, Faizaan; Uffman, Joshua C; Tumin, Dmitry; Flaitz, Catherine M; Tobias, Joseph D; Raman, Vidya T

    2018-01-01

    Few data exist on combining pediatric surgical procedures under a single general anesthetic encounter (general anesthesia). We compared perioperative outcomes of combining dental surgical procedures with tonsillectomy during one anesthetic vs separate encounters. We classified elective tonsillectomy ± adenoidectomy and restorative dentistry as combined (group C) or separate (group S). Outcomes included anesthesia time, recovery duration, the need for overnight hospital stay, and postoperative complications. Patients aged 4±1 years underwent tonsillectomy and dental surgery in combination (n=7) or separately (n=27). No differences were noted in total anesthesia time (C: median: 150, interquartile range [IQR]: 99, 165 vs S: median: 109, IQR: 92, 132; 95% CI of difference in median: -58, +10 minutes; P =0.115) and total recovery time (C: median: 54, IQR: 40, 108 vs S: median: 72, IQR: 58, 109; 95% CI of difference in median: -16, +48 minutes; P =0.307). The need for overnight stay (C: 4 of 7, S: 20 of 27; P =0.394) did not differ between the groups. No postoperative complications were noted in either group. These preliminary data support the potential feasibility of combining dental procedures with tonsillectomy during a single anesthetic encounter. Such care may not only reduce costs but also limit parental work absences and increase convenience for patient families. When compared with procedures performed separately, combined procedures did not result in increased morbidity or significant changes in postoperative outcomes.

  2. Onyx Embolization for Isolated Type Dural Arteriovenous Fistula Using a Dual-Lumen Balloon Catheter.

    PubMed

    Kim, Jin Woo; Kim, Byung Moon; Park, Keun Young; Kim, Dong Joon; Kim, Dong Ik

    2016-05-01

    Utilization of a dual-lumen balloon may improve Onyx penetration into isolated dural arteriovenous fistulas (i-DAVFs). To compare the results of Onyx embolization using a dual-lumen balloon with those using a non-balloon catheter for i-DAVFs. Twenty-nine patients underwent Onyx embolization for i-DAVFs using a non-balloon (n = 14) or a dual-lumen balloon catheter (n = 15). Since its introduction, a dual-lumen balloon catheter has been preferred. We compared the dual-lumen balloon group with the non-balloon catheter group regarding angiographic outcome, treatment-related complications, total procedural time, Onyx injection time, and the number of feeders requiring embolization. The dual-lumen balloon group showed complete occlusion of i-DAVFs in 13 and near-complete in 2 patients, while the non-balloon group showed complete occlusion in 5, near-complete in 5, and incomplete in 4 patients (P < .05). Treatment-related complications occurred in 2 patients: 1 in the non-balloon group and 1 in the dual-lumen balloon group. The mean total procedural time was 62 ± 32 minutes in the dual-lumen balloon and 171 ± 88 minutes in the non-balloon group (P < .05). The mean Onyx injection time was 10 ± 6 minutes in the dual-lumen balloon and 49 ± 32 minutes in the non-balloon group (P < .05). The median number of feeders requiring embolization was 1 (range, 1-3) in the dual-lumen balloon and 2 (range, 1-4) in the non-balloon group (P < .05). Utilization of a dual-lumen balloon catheter for Onyx embolization of i-DAVF seemed to significantly increase the immediate complete occlusion rate and decrease total procedural time, Onyx injection time, and number of feeders requiring embolization.

  3. Reduced Operating Time but Not Blood Loss With Cruciate Retaining Total Knee Arthroplasty

    PubMed Central

    Vermesan, Dinu; Trocan, Ilie; Prejbeanu, Radu; Poenaru, Dan V; Haragus, Horia; Gratian, Damian; Marrelli, Massimo; Inchingolo, Francesco; Caprio, Monica; Cagiano, Raffaele; Tatullo, Marco

    2015-01-01

    Background There is no consensus regarding the use of retaining or replacing cruciate implants for patients with limited deformity who undergo a total knee replacement. Scope of this paper is to evaluate whether a cruciate sparing total knee replacement could have a reduced operating time compared to a posterior stabilized implant. Methods For this purpose, we performed a randomized study on 50 subjects. All procedures were performed by a single surgeon in the same conditions to minimize bias and only knees with a less than 20 varus deviation and/or maximum 15° fixed flexion contracture were included. Results Surgery time was significantly shorter with the cruciate retaining implant (P = 0.0037). The mean duration for the Vanguard implant was 68.9 (14.7) and for the NexGen II Legacy was 80.2 (11.3). A higher range of motion, but no significant Knee Society Scores at 6 months follow-up, was used as controls. Conclusions In conclusion, both implants had the potential to assure great outcomes. However, if a decision has to be made, choosing a cruciate retaining procedure could significantly reduce the surgical time. When performed under tourniquet, this gain does not lead to reduced blood loss. PMID:25584102

  4. [Implementation of a patient data management system. Effects on intensive care documentation].

    PubMed

    Castellanos, I; Ganslandt, T; Prokosch, H U; Schüttler, J; Bürkle, T

    2013-11-01

    Patient data management systems (PDMS) enable digital documentation on intensive care units (ICU). A commercial PDMS was implemented in a 25-bed ICU replacing paper-based patient charting. The ICU electronic patient record is completely managed inside the PDMS. It compiles data from vital signs monitors, ventilators and further medical devices and facilitates some drug dose and fluid balance calculations as well as data reuse for administrative purposes. Ventilation time and patient severity scoring as well as coding of diagnoses and procedures is supported. Billing data transferred via interface to the central billing system of the hospital. Such benefits should show in measurable parameters, such as documented ventilator time, number of coded diagnoses and procedures and others. These parameters influence reimbursement in the German DRG system. Therefore, measurable changes in cost and reimbursement data of the ICU were expected. A retrospective analysis of documentation quality parameters, cost data and mortality rate of a 25-bed surgical ICU within a German university hospital 3 years before (2004-2006) and 5 years after (2007-2011) PDMS implementation. Selected parameters were documented electronically, consistently and reproducibly for the complete time span of 8 years including those years where no electronic patient recording was available. The following parameters were included: number of cleared DRG, cleared ventilator time, case mix (CM), case mix index (CMI), length of stay, number of coded diagnoses and procedures, detailed overview of a specific procedure code based on daily Apache II and TISS Core 10 scores, mortality, total ICU costs and revenues and partial profits for specific ICU procedures, such as renal replacement therapy and blood products. Systematic shifts were detected over the study period, such as increasing case numbers and decreasing length of stay as well as annual fluctuations in severity of disease seen in the CM and CMI. After PDMS introduction, the total number of coded diagnoses increased but the proportion of DRG relevant diagnoses dropped significantly. The number of procedures increased (not significantly) and the number of procedures per case did not rise significantly. The procedure 8-980 showed a significant increase after PDMS introduction whereas the DRG-relevant proportion of those procedures dropped insignificantly. The number of ventilator-associated DRG cases as well as the total ventilator time increased but not significantly. Costs and revenues increased slightly but profit varied considerably from year to year in the 5 years after system implementation. A small increase was observed per case, per nursing day and per case mix point. Additional revenues for specific ICU procedures increased in the years before and dropped after PDMS implementation. There was an insignificant increase in ICU mortality rate from 7.4 % in the year 2006 (before) to 8.5 % in 2007 (after PDMS implementation). In the following years mortality dropped below the base level. The implementation of the PDMS showed only small effects on documentation of reimbursement-relevant parameters which were too small to set off against the total investment. The method itself, a long-term follow-up of different parameters proved successful and can be adapted by other organizations. The quality of results depends on the availability of long-term parameters in good quality. No significant influence of PDMS on mortality was found.

  5. SU-F-I-77: Radiation Dose in Cardiac Catheterization Procedures: Impact of a Systematic Reduction in Pulsed Fluoroscopy Frame Rate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schultz, C; Dixon, S

    Purpose: To evaluate whether one small systematic reduction in fluoroscopy frame rate has a significant effect on the total air kerma and/or dose area product for diagnostic and interventional cardiac catheterization procedures. Methods: The default fluoroscopy frame rate (FFR) was lowered from 15 to 10 fps in 5 Siemens™ Axiom Artis cardiac catheterization labs (CCL) on July 1, 2013. A total of 7212 consecutive diagnostic and interventional CCL procedures were divided into two study groups: 3602 procedures from 10/1/12 –6/30/13 with FFR of 15 fps; and 3610 procedures 7/1/13 – 3/31/14 at 10 fps. For each procedure, total air kermamore » (TAK), fluoroscopy skin dose (FSD), total/fluoroscopy dose area products (TAD, FAD), and total fluoroscopy time (FT) were recorded. Patient specific data collected for each procedure included: BSA, sex, height, weight, interventional versus diagnostic; and elective versus emergent. Results: For pre to post change in FFR, each categorical variable was compared using Pearson’s Chi-square test, Odds ratios and 95% confidence intervals. No statistically significant difference in BSA, height, weight, number of interventional versus diagnostic, elective versus emergent procedures was found between the two study groups. Decreasing the default FFR from 15 fps to 10 fps in the two study groups significantly reduced TAK from 1305 to 1061 mGy (p<0.0001), FSD from 627 to 454 mGy (p<0.0001), TAD from 8681 to 6991 uGy × m{sup 2}(p<0.0001), and FAD from 4493 to 3297 uGy × m{sup 2}(p<0.0001). No statistically significant difference in FT was noted. Clinical image quality was not analyzed, and reports of noticeable effects were minimal. From July 1, 2013 to date, the default FFR has remained 10 fps. Conclusion: Reducing the FFR from 15 to 10 fps significantly reduced total air kerma and dose area product which may decrease risk for potential radiation-induced skin injuries and improve patient outcomes.« less

  6. Mitigating the risk of food handling in the home-delivered meal program.

    PubMed

    Namkung, Young; Ismail, Joseph A; Almanza, Barbara A; Nelson, Douglas C

    2007-02-01

    The purpose of this cross-sectional study was to examine the length of time between packing and delivery of home-delivered meals, and the extent of foodborne illness risk to the elderly. Procedures to mitigate that risk were also evaluated. Researchers surveyed 95 drivers from home-delivered meal preparation sites in six states across the United States to determine the average length of time that passed during packing, loading, leaving, and delivery. The efficiency of various risk mitigation methods were evaluated and used to adjust the actual delivery time. Total average delivery time from packing to last delivery was 1.92 hours. This study suggests that the risk associated with the actual 1.92 hours of total delivery time could be mitigated to represent approximately 1.55 hours of effective time with proper packing and holding conditions. This methodology proposes a single measure for evaluating the effectiveness of various handling procedures associated with distributing home-delivered meals, which can be utilized to evaluate overall risk when combined with in-house preparation and client-handling behaviors.

  7. Ketamine versus alfentanil combined with propofol for sedation in colonoscopy procedures: a randomized prospective study.

    PubMed

    Türk, Hacer Şebnem; Aydoğmuş, Meltem; Ünsal, Oya; Işıl, Canan Tülay; Citgez, Bülent; Oba, Sibel; Açık, Mehmet Eren

    2014-12-01

    Different drug combinations are used for sedation in colonoscopy procedures. A ketamine-propofol (ketofol) mixture provides effective sedation and has minimal adverse effects. Alfentanil also provides anesthesia for short surgical procedures by incremental injection as an adjunct. However, no study has investigated the use of ketofol compared with an opioid-propofol combination in colonoscopic procedures. A total of 70 patients, ASA physical status I-II, scheduled to undergo elective colonoscopy, were enrolled in this prospective randomized study and allocated to two groups. After premedication, sedation induction was performed with 0.5 mg/kg ketamine +1 mg/kg propofol in Group KP, and 10 mg/kg alfentanil +1 mg/kg propofol in Group AP. Propofol was added when required. Demographic data, colonoscopy duration, recovery time, discharge time, mean arterial pressure (MAP), heart rate (HR), peripheral oxygen saturation, Ramsey Sedation Scale values, colonoscopy patients' satisfaction scores, and complications were recorded. The need for additional propofol doses was significantly higher in Group AP than in Group KP. MAP at minute 1 and 5, Ramsey Sedation Scale at minute 5, and discharge time were significantly higher in Group KP than in Group AP. Additional propofol doses and total propofol dose were significantly lower in Group KP than in Group AP. Ketofol provided better hemodynamic stability and quality of sedation compared with alfentanil-propofol combination in elective colonoscopy, and required fewer additional propofol; however, it prolonged discharge time. Both combinations can safely be used in colonoscopy sedation.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Das, Raj, E-mail: rajdas@nhs.net, E-mail: raj.das@stgeorges.nhs.uk; Lucatelli, Pierleone, E-mail: pierleone.lucatelli@gmail.com; Wang, Haofan, E-mail: wwhhff123@gmail.com

    AimA clear understanding of operator experience is important in improving technical success whilst minimising patient risk undergoing endovascular procedures, and there is the need to ensure that trainees have the appropriate skills as primary operators. The aim of the study is to retrospectively analyse uterine artery embolisation (UAE) procedures performed by interventional radiology (IR) trainees at an IR training unit analysing fluoroscopy times and radiation dose as surrogate markers of technical skill.MethodsTen IR fellows were primary operator in 200 UAE procedures over a 5-year period. We compared fluoroscopy times, radiation dose and complications, after having them categorised according to threemore » groups: Group 1, initial five, Group 2, >5 procedures and Group 3, penultimate five UAE procedures. We documented factors that may affect screening time (number of vials employed and use of microcatheters).ResultsMean fluoroscopy time was 18.4 (±8.1), 17.3 (±9.0), 16.3 (±8.4) min in Groups 1, 2 and 3, respectively. There was no statistically significant difference between these groups (p > 0.05) with respect to fluoroscopy time or radiation dose. Analysis after correction for confounding factors showed no statistical significance (p > 0.05). All procedures were technically successful, and total complication rate was 4 %.ConclusionUAE was chosen as a highly standardised procedure followed by IR practitioners. Although there is a non-significant trend for shorter screening times with experience, technical success and safety were not compromised with appropriate Consultant supervision, which illustrates a safe construct for IR training. This is important and reassuring information for patients undergoing a procedure in a training unit.« less

  9. Success rates for initial eradication of peri-prosthetic knee infection treated with a two-stage procedure.

    PubMed

    Kaminski, Andrzej; Citak, Mustafa; Schildhauer, Thomas Armin; Fehmer, Tobias

    2014-01-01

    In Germany, rates of primary total knee arthroplasty procedures and exchange arthroplasty procedures continue to rise. Late-onset peri-prosthetic infection constitutes a serious complication whose management may be dependent upon the spectrum of micro-organisms involved. The aim of this study was to provide a retrospective analysis of the effectiveness of initial eradication measures performed as part of a two-stage procedure. Between 2002 and 2008, a total of 328 patients who had received a first-time diagnosis of chronic peri-prosthetic knee infection following total knee arthroplasty (TKA) subsequently underwent surgery at our clinic. The surgical approach consisted of a two-stage procedure, with the initial procedure consisting of the removal of the prosthesis and radical debridement, followed by insertion of an antibiotic-loaded static spacer. The effectiveness of the procedure was assessed after six weeks, with each patient undergoing a number of clinical and laboratory-based tests, including knee joint aspiration. Staphylococcus aureus strains were responsible for 68% (n=223) of the total number of cases of peri-prosthetic knee infection. 19% of cases (n=62) showed evidence of gram-negative bacteria, while MRSA accounted for 15% (n=49) of cases. Six weeks after completion of the above-named treatment regimen, eradication of infection was considered successful in 289 patients (88.1%). Eradication was unsuccessful in 22% of MRSA infections (n=11) and 7% of MSSA infections (n=23). The treatment regimen outlined in this report is capable of achieving satisfactory results in the management of late-onset peri-prosthetic knee infection, with one exception: patients with infections caused by MRSA showed high failure rates.

  10. A parallel second-order adaptive mesh algorithm for incompressible flow in porous media.

    PubMed

    Pau, George S H; Almgren, Ann S; Bell, John B; Lijewski, Michael J

    2009-11-28

    In this paper, we present a second-order accurate adaptive algorithm for solving multi-phase, incompressible flow in porous media. We assume a multi-phase form of Darcy's law with relative permeabilities given as a function of the phase saturation. The remaining equations express conservation of mass for the fluid constituents. In this setting, the total velocity, defined to be the sum of the phase velocities, is divergence free. The basic integration method is based on a total-velocity splitting approach in which we solve a second-order elliptic pressure equation to obtain a total velocity. This total velocity is then used to recast component conservation equations as nonlinear hyperbolic equations. Our approach to adaptive refinement uses a nested hierarchy of logically rectangular grids with simultaneous refinement of the grids in both space and time. The integration algorithm on the grid hierarchy is a recursive procedure in which coarse grids are advanced in time, fine grids are advanced multiple steps to reach the same time as the coarse grids and the data at different levels are then synchronized. The single-grid algorithm is described briefly, but the emphasis here is on the time-stepping procedure for the adaptive hierarchy. Numerical examples are presented to demonstrate the algorithm's accuracy and convergence properties and to illustrate the behaviour of the method.

  11. A Web-based Multimedia Program Before Colonoscopy Increased Knowledge and Decreased Anxiety, Sedation Requirement, and Procedure Time.

    PubMed

    Parker, Siddhartha; Zipursky, Jonathan; Ma, Helen; Baumblatt, Geri-Lynn; Siegel, Corey A

    2018-07-01

    Assess the impact of a web-based multimedia patient engagement program on patient anxiety, perception and knowledge about the colonoscopy in addition to procedure outcomes. The success of patients coming for a colonoscopy for colorectal cancer screening is dependent in part on patients' understanding of the preparation and of the procedure. Patients were randomized to use either our institution's standard preprocedure colonoscopy packet or a web-based multimedia patient engagement program (Emmi Solutions) before their scheduled procedure. On the day of colonoscopy, all participants completed a survey including questions to assess knowledge and perception of colonoscopy, in addition to the State Trait Anxiety Inventory. We also collected procedure data including medication doses and procedure time. Patients in the experimental group correctly answered knowledge questions (82%) more often than the control group (74%) (P=0.0003). More than half (58%) of patients in the experimental group felt this intervention reduced their anxiety about the procedure, and the State Trait Anxiety Inventory anxiety score was lower in the experimental group (P=0.026). Patients who viewed the program required less midazolam (3.66 vs. 4.46 mg, P=0.0035) and total procedure time was shorter (24.8 vs. 29 min, P=0.024). A web-based multimedia patient engagement program watched before colonoscopy decreased patient anxiety, medication requirements, and procedure time while increasing knowledge. This intervention could help patients understand and feel more comfortable about colonoscopy leading to increased screening rates while increasing efficiency and decreasing recovery time.

  12. Physician Assistants Improve Efficiency and Decrease Costs in Outpatient Oral and Maxillofacial Surgery.

    PubMed

    Resnick, Cory M; Daniels, Kimberly M; Flath-Sporn, Susan J; Doyle, Michael; Heald, Ronald; Padwa, Bonnie L

    2016-11-01

    To determine the effects on time, cost, and complication rates of integrating physician assistants (PAs) into the procedural components of an outpatient oral and maxillofacial surgery practice. This is a prospective cohort study of patients from the Department of Plastic and Oral Surgery at Boston Children's Hospital who underwent removal of 4 impacted third molars with intravenous sedation in our outpatient facility. Patients were separated into the "no PA group" and PA group. Process maps were created to capture all activities from room preparation to patient discharge, and all activities were timed for each case. A time-driven activity-based costing method was used to calculate the average times and costs from the provider's perspective for each group. Complication rates were calculated during the periods for both groups. Descriptive statistics were calculated, and significance was set at P < .05. The total process time did not differ significantly between groups, but the average total procedure cost decreased by $75.08 after the introduction of PAs (P < .001). The time that the oral and maxillofacial surgeon was directly involved in the procedure decreased by an average of 19.2 minutes after the introduction of PAs (P < .001). No significant differences in postoperative complications were found. The addition of PAs into the procedural components of an outpatient oral and maxillofacial surgery practice resulted in decreased costs whereas complication rates remained constant. The increased availability of the oral and maxillofacial surgeon after the incorporation of PAs allows for more patients to be seen during a clinic session, which has the potential to further increase efficiency and revenue. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Spinal Surgeon Variation in Single-Level Cervical Fusion Procedures: A Cost and Hospital Resource Utilization Analysis.

    PubMed

    Hijji, Fady Y; Massel, Dustin H; Mayo, Benjamin C; Narain, Ankur S; Long, William W; Modi, Krishna D; Burke, Rory M; Canar, Jeff; Singh, Kern

    2017-07-01

    Retrospective analysis. To compare perioperative costs and outcomes of patients undergoing single-level anterior cervical discectomy and fusions (ACDF) at both a service (orthopedic vs. neurosurgical) and individual surgeon level. Hospital systems are experiencing significant pressure to increase value of care by reducing costs while maintaining or improving patient-centered outcomes. Few studies have examined the cost-effectiveness cervical arthrodesis at a service level. A retrospective review of patients who underwent a primary 1-level ACDF by eight surgeons (four orthopedic and four neurosurgical) at a single academic institution between 2013 and 2015 was performed. Patients were identified by Diagnosis-Related Group and procedural codes. Patients with the ninth revision of the International Classification of Diseases coding for degenerative cervical pathology were included. Patients were excluded if they exhibited preoperative diagnoses or postoperative social work issues affecting their length of stay. Comparisons of preoperative demographics were performed using Student t tests and chi-squared analysis. Perioperative outcomes and costs for hospital services were compared using multivariate regression adjusted for preoperative characteristics. A total of 137 patients diagnosed with cervical degeneration underwent single-level ACDF; 44 and 93 were performed by orthopedic surgeons and neurosurgeons, respectively. There was no difference in patient demographics. ACDF procedures performed by orthopedic surgeons demonstrated shorter operative times (89.1 ± 25.5 vs. 96.0 ± 25.5 min; P = 0.002) and higher laboratory costs (Δ+$6.53 ± $5.52 USD; P = 0.041). There were significant differences in operative time (P = 0.014) and labor costs (P = 0.034) between individual surgeons. There was no difference in total costs between specialties or individual surgeons. Surgical subspecialty training does not significantly affect total costs of ACDF procedures. Costs can, however, vary between individual surgeons based on operative times. Variation between individual surgeons highlights potential areas for improvement of the cost effectiveness of spinal procedures. 4.

  14. Learning curve in transradial cardiac catheterization: procedure-related parameters stratified by operators' transradial volume.

    PubMed

    Kasasbeh, Ehab S; Parvez, Babar; Huang, Robert L; Hasselblad, Michele Marie; Glazer, Mark D; Salloum, Joseph G; Cleator, John H; Zhao, David X

    2012-11-01

    To determine whether radial artery access is associated with a reduction in fluoroscopy time, procedure time, and other procedural variables over a 27-month period during which the radial artery approach was incorporated in a single academic Medical Center. Although previous studies have demonstrated a relationship between increased volume and decreased procedural time, no studies have looked at the integration of radial access over time. Data were collected from consecutive patients who presented to the Vanderbilt University Medical Center cardiac catheterization laboratory from January 1, 2009 to April 1, 2011. Patients who underwent radial access diagnostic catheterization with and without percutaneous coronary intervention were included in this study. A total of 1112 diagnostic cardiac catheterizations through the radial access site were analyzed. High-volume, intermediate-volume, and low-volume operators were grouped based on the percentage of procedures performed through a radial approach. From 2009 to 2011, there was a significant decrease in fluoroscopy time in all operator groups for diagnostic catheterization (P=.035). The high-volume operator group had 1.88 and 3.66 minute reductions in fluoroscopy time compared to the intermediate- and low-volume operator groups, respectively (both P<.001). Likewise, the intermediate-volume operator group had a 1.77 minute improvement compared to the low-volume operator group, but this did not reach statistical significance (P=.102). The improvement in fluoroscopy time and other procedure-related parameters was seen after approximately 25 cases with further improvement after 75 cases. The incorporation of the radial access approach in the cardiac catheterization laboratory led to a decrease in fluoroscopy time for each operator and operator group over the last 3 years. Our data demonstrated that higher-volume radial operators have better procedure, room, and fluoroscopy times when compared to intermediate- and low-volume operators. However, lower-volume operators have a reduction in procedure-related parameters with increased radial cases. Number of procedures needed to become sufficient was demonstrated in the current study.

  15. Using Time Delay to Teach Literacy to Students with Severe Developmental Disabilities

    ERIC Educational Resources Information Center

    Browder, Diane; Ahlgrim-Delzell, Lynn; Spooner, Fred; Mims, Pamela J.; Baker, Joshua N.

    2009-01-01

    A review of the literature was conducted for articles published between 1975 and 2007 on the application of time delay as an instructional procedure to teach word and picture recognition to students with severe developmental disabilities in an effort to evaluate time delay as an evidence-based practice. A total of 30 experiments were analyzed…

  16. A Guide for Montana School Libraries; A Manual of Basic Library Procedures for Montana Schools, Developed by Montana Teachers and Librarians.

    ERIC Educational Resources Information Center

    Montana State Dept. of Public Instruction, Helena.

    Basic procedures for setting up a new school library or for maintaining an established one are described to help economize the librarian's efforts and assist in establishing effective organization. Use of this guide to streamline library routine will give librarians more time to assist school personnel and to develop a better total library…

  17. Total laparoscopic gastropexy using 1 simple continuous barbed suture line in 63 dogs.

    PubMed

    Takacs, Joel D; Singh, Ameet; Case, J Brad; Mayhew, Philipp D; Giuffrida, Michelle A; Caceres, Ana V; Fox-Alvarez, W Alexander; Runge, Jeffrey J

    2017-02-01

    To describe the use and outcome of a single, simple continuous, barbed suture line for prophylactic, total laparoscopic gastropexy in dogs. Multi-center, retrospective case series. Sixty-three client-owned dogs. Medical records of dogs undergoing total laparoscopic gastropexy using a barbed suture at 4 academic veterinary hospitals from 2011-2015 were reviewed. Data collected included signalment, procedure time, procedure-associated complications, short-term complications, and long-term outcome. All procedures were performed under general anesthesia in dorsal to dorsal-left oblique recumbency. Laparoscopic ports were placed on ventral midline in 1 of 3 port configurations, and 5 mm laparoscopic needle drivers were used for intracorporeal sutured gastropexy with unidirectional barbed suture. The gastropexy was positioned just caudal to the 13th rib, 2-4 cm lateral to the rectus abdominis muscle. Sixty-three dogs underwent total laparoscopic gastropexy with a single, simple continuous, barbed suture line. Median gastropexy surgery time was 70 minutes (interquartile range [IQR] 60-90 minutes). One dog sustained splenic laceration from Veress needle penetration during initial abdominal insufflation. Short term (>24 hours to 6 months postoperative) complications included incisional seroma formation (n = 2) and suture reaction (n = 1). Long term (>6 months postoperative) complications included intermittent regurgitation and chronic diarrhea in 1 dog. Fifteen dogs had postoperative ultrasound and all had intact gastropexy sites. Total laparoscopic barbed gastropexy using a single, simple continuous, barbed suture line in dogs is safe and results in an intact gastropexy long term. © 2016 The American College of Veterinary Surgeons.

  18. 34 CFR 675.19 - Fiscal procedures and records.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... EDUCATION, DEPARTMENT OF EDUCATION FEDERAL WORK-STUDY PROGRAMS Federal Work-Study Program § 675.19 Fiscal... paid on an hourly basis, a time record showing the hours each student worked in clock time sequence, or the total hours worked per day; (ii) Include a payroll voucher containing sufficient information to...

  19. 34 CFR 675.19 - Fiscal procedures and records.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... EDUCATION, DEPARTMENT OF EDUCATION FEDERAL WORK-STUDY PROGRAMS Federal Work-Study Program § 675.19 Fiscal... paid on an hourly basis, a time record showing the hours each student worked in clock time sequence, or the total hours worked per day; (ii) Include a payroll voucher containing sufficient information to...

  20. After-hour Versus Daytime Shifts in Non-Operating Room Anesthesia Environments: National Distribution of Case Volume, Patient Characteristics, and Procedures.

    PubMed

    Gabriel, Rodney A; Burton, Brittany N; Tsai, Mitchell H; Ehrenfeld, Jesse M; Dutton, Richard P; Urman, Richard D

    2017-09-01

    The objective of this study was to characterize workload during all hours of the day in the non-operating room anesthesia (NORA) environment and identify what type of patients and procedures were more likely to occur during after-hours. By investigating data from the National Anesthesia Clinical Outcomes Registry, we characterized the total number of ongoing NORA cases per hour of the day (0 - 23 h). Results were presented as the mean hour and standard error (SE). Multivariable logistic regression was applied to assess the association of various patient, procedural, and facility characteristics with time of day (after-hours = 17:01-06:59 local time versus day-time). Included in this analysis, there were a total of 4,948,634 cases performed on non-holiday weekdays. The mean hour for ongoing cases for gastroenterology, cardiac, radiology and "other" were: 10.8 with standard error (SE) of 0.002, 11.5 (SE of 0.005), 11.2 (SE of 0.005), and 10.8 (SE of 0.002), respectively. Pairwise differences between means for each NORA specialty were all statistically significant (p < 0.0001). During after-hour shifts (4.3% of cases), patients with higher American Society of Anesthesiologists physical status classification scores had increased odds for undergoing a NORA procedure, while procedures that were more physiologically complex had decreased odds. With the increasing demand for NORA services, it is prudent that we fully understand the challenges of providing safe and efficient anesthetic services particularly in locations where fewer resources are available.

  1. The Effect of Realtime Monitoring on Dose Exposure to Staff Within an Interventional Radiology Setting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baumann, Frederic, E-mail: fredericbaumann@hotmail.com; Katzen, Barry T.; Carelsen, Bart

    PurposeThe purpose of this study is to evaluate a new device providing real-time monitoring on radiation exposure during fluoroscopy procedures intending to reduce radiation in an interventional radiology setting.Materials and MethodsIn one interventional suite, a new system providing a real-time radiation dose display and five individual wireless dosimeters were installed. The five dosimeters were worn by the attending, fellow, nurse, technician, and anesthesiologist for every procedure taking place in that suite. During the first 6-week interval the dose display was off (closed phase) and activated thereafter, for a 6-week learning phase (learning phase) and a 10-week open phase (open phase).more » During these phases, the staff dose and the individual dose for each procedure were recorded from the wireless dosimeter and correlated with the fluoroscopy time. Further subanalysis for dose exposure included diagnostic versus interventional as well as short (<10 min) versus long (>10 min) procedures.ResultsA total of 252 procedures were performed (n = 88 closed phase, n = 50 learning phase, n = 114 open phase). The overall mean staff dose per fluoroscopic minute was 42.79 versus 19.81 µSv/min (p < 0.05) comparing the closed and open phase. Thereby, anesthesiologists were the only individuals attaining a significant dose reduction during open phase 16.9 versus 8.86 µSv/min (p < 0.05). Furthermore, a significant reduction of total staff dose was observed for short 51 % and interventional procedures 45 % (p < 0.05, for both).ConclusionA real-time qualitative display of radiation exposure may reduce team radiation dose. The process may take a few weeks during the learning phase but appears sustained, thereafter.« less

  2. Laparoscopic versus robotic-assisted Roux-en-Y gastric bypass: a retrospective, single-center study of early perioperative outcomes at a community hospital.

    PubMed

    Ahmad, Arif; Carleton, Jared D; Ahmad, Zoha F; Agarwala, Ashish

    2016-09-01

    The purpose of this study was to compare the operative and early perioperative outcomes of laparoscopic versus robotic-assisted Roux-en-Y gastric bypass procedures performed in a community hospital setting. The study was a chart review and analysis of the early perioperative outcomes of a total of 345 Roux-en-Y gastric bypass procedures performed by a single surgeon in a community hospital setting from January 2011 to October 2014. Of these, 173 procedures were performed laparoscopically and 172 were performed with robotic assistance utilizing the daVinci(®) surgical platform. Factors such as baseline patient characteristics, operative time, estimated blood loss (EBL), conversions to open procedure, complication rates, adverse events, length of stay (LOS), and return to the operating room for the two groups were retrospectively analyzed from a prospectively maintained database. Student's t test with unequal variances was used for statistical analysis, and a p value <0.05 was used for significance. There were no statistically significant differences in complication rates, EBL, or LOS between the two groups. There was a significant difference between the total operative times (135.30 ± 37.60 min for the laparoscopic procedure versus 154.84 ± 38.44 min for the robotic procedure, p < 0.05). There were no adverse intraoperative events, conversions to open procedures, leaks, strictures, returns to the operating room within 30 days, or mortalities in either group. Our study, which is the first of its kind to analyze the operative and early perioperative outcomes between laparoscopic and robotic-assisted Roux-en-Y gastric bypass procedures in the US community hospital setting, indicates that both are comparable in terms of safety, efficacy, and operative and early perioperative outcomes.

  3. The use of theatre time for paediatric dentistry under general anaesthesia.

    PubMed

    Foley, Jennifer; Soldani, Francesca

    2007-01-01

    The aim of this paper was to determine the use of theatre time for all procedures performed under general anaesthetic on a paediatric dental list. A prospective study of paediatric dental general anaesthetic procedures was undertaken at Ninewells Hospital and Medical School, NHS Tayside, Dundee, UK. Data were collected prospectively for 71 operating lists over a 3-year period from April 2003 to March 2006. Both operator status and the procedure being undertaken were recorded. In addition, pre-anaesthetic, anaesthetic, operating and disconnection times were recorded. Of the 71 lists examined, 61 either finished early or on time, with a median unused time of 32.50 min (interquartile range = 19.50, 50.00 min), whilst 10 lists finished late with a median overrun time of 30.50 min (interquartile range = 9.25, 45.50 min). Comparing lists which finished late with those which were completed within time, the median pre-anaesthetic time was significantly longer (Mann-Whitney U-test, W = 20.05, P = 0.048). Overall, the theatre was in use for 78.22% of time combining pre-anaesthetic, anaesthetic, operating and disconnection times; hence, there was poor time utilization of theatre for 21.78% of the total theatre time. Overall, 85.9% of theatre sessions for dental procedures under general anaesthetic in children finished early or on time. Where lists finished late, the duration of the pre-anaesthetic time appeared to be the significant factor.

  4. Minimally invasive video-assisted thyroidectomy: Ascending the learning curve

    PubMed Central

    Capponi, Michela Giulii; Bellotti, Carlo; Lotti, Marco; Ansaloni, Luca

    2015-01-01

    BACKGROUND: Minimally invasive video-assisted thyroidectomy (MIVAT) is a technically demanding procedure and requires a surgical team skilled in both endocrine and endoscopic surgery. The aim of this report is to point out some aspects of the learning curve of the video-assisted thyroid surgery, through the analysis of our preliminary series of procedures. PATIENTS AND METHODS: Over a period of 8 months, we selected 36 patients for minimally invasive video-assisted surgery of the thyroid. The patients were considered eligible if they presented with a nodule not exceeding 35 mm and total thyroid volume <20 ml; presence of biochemical and ultrasound signs of thyroiditis and pre-operative diagnosis of cancer were exclusion criteria. We analysed surgical results, conversion rate, operating time, post-operative complications, hospital stay and cosmetic outcomes of the series. RESULTS: We performed 36 total thyroidectomy and in one case we performed a consensual parathyroidectomy. The procedure was successfully carried out in 33 out of 36 cases (conversion rate 8.3%). The mean operating time was 109 min (range: 80-241 min) and reached a plateau after 29 MIVAT. Post-operative complications included three transient recurrent nerve palsies and two transient hypocalcemias; no definitive hypoparathyroidism was registered. The cosmetic result was considered excellent by most patients. CONCLUSIONS: Advances in skills and technology allow surgeons to easily reproduce the standard open total thyroidectomy with video-assistance. Although the learning curve represents a time-consuming step, training remains a crucial point in gaining a reasonable confidence with video-assisted surgical technique. PMID:25883451

  5. Time Management in the Operating Room: An Analysis of the Dedicated Minimally Invasive Surgery Suite

    PubMed Central

    Hsiao, Kenneth C.; Machaidze, Zurab

    2004-01-01

    Background: Dedicated minimally invasive surgery suites are available that contain specialized equipment to facilitate endoscopic surgery. Laparoscopy performed in a general operating room is hampered by the multitude of additional equipment that must be transported into the room. The objective of this study was to compare the preparation times between procedures performed in traditional operating rooms versus dedicated minimally invasive surgery suites to see whether operating room efficiency is improved in the specialized room. Methods: The records of 50 patients who underwent laparoscopic procedures between September 2000 and April 2002 were retrospectively reviewed. Twenty-three patients underwent surgery in a general operating room and 18 patients in an minimally invasive surgery suite. Nine patients were excluded because of cystoscopic procedures undergone prior to laparoscopy. Various time points were recorded from which various time intervals were derived, such as preanesthesia time, anesthesia induction time, and total preparation time. A 2-tailed, unpaired Student t test was used for statistical analysis. Results: The mean preanesthesia time was significantly faster in the minimally invasive surgery suite (12.2 minutes) compared with that in the traditional operating room (17.8 minutes) (P=0.013). Mean anesthesia induction time in the minimally invasive surgery suite (47.5 minutes) was similar to time in the traditional operating room (45.7 minutes) (P=0.734). The average total preparation time for the minimally invasive surgery suite (59.6 minutes) was not significantly faster than that in the general operating room (63.5 minutes) (P=0.481). Conclusion: The amount of time that elapses between the patient entering the room and anesthesia induction is statically shorter in a dedicated minimally invasive surgery suite. Laparoscopic surgery is performed more efficiently in a dedicated minimally invasive surgery suite versus a traditional operating room. PMID:15554269

  6. Intraoperative and postoperative feasibility and safety of total tubeless, tubeless, small-bore tube, and standard percutaneous nephrolithotomy: a systematic review and network meta-analysis of 16 randomized controlled trials.

    PubMed

    Lee, Joo Yong; Jeh, Seong Uk; Kim, Man Deuk; Kang, Dong Hyuk; Kwon, Jong Kyou; Ham, Won Sik; Choi, Young Deuk; Cho, Kang Su

    2017-06-27

    Percutaneous nephrolithotomy (PCNL) is performed to treat relatively large renal stones. Recent publications indicate that tubeless and total tubeless (stentless) PCNL is safe in selected patients. We performed a systematic review and network meta-analysis to evaluate the feasibility and safety of different PCNL procedures, including total tubeless, tubeless with stent, small-bore tube, and large-bore tube PCNLs. PubMed, Cochrane Central Register of Controlled Trials, and EMBASE™ databases were searched to identify randomized controlled trials published before December 30, 2013. One researcher examined all titles and abstracts found by the searches. Two investigators independently evaluated the full-text articles to determine whether those met the inclusion criteria. Qualities of included studies were rated with Cochrane's risk-of-bias assessment tool. Sixteen studies were included in the final syntheses including pairwise and network meta-analyses. Operation time, pain scores, and transfusion rates were not significantly different between PCNL procedures. Network meta-analyses demonstrated that for hemoglobin changes, total tubeless PCNL may be superior to standard PCNL (mean difference [MD] 0.65, 95% CI 0.14-1.13) and tubeless PCNLs with stent (MD -1.14, 95% CI -1.65--0.62), and small-bore PCNL may be superior to tubeless PCNL with stent (MD 1.30, 95% CI 0.27-2.26). Network meta-analyses also showed that for length of hospital stay, total tubeless (MD 1.33, 95% CI 0.23-2.43) and tubeless PCNLs with stent (MD 0.99, 95% CI 0.19-1.79) may be superior to standard PCNL. In rank probability tests, small-bore tube and total tubeless PCNLs were superior for operation time, pain scores, and hemoglobin changes. For hemoglobin changes, total tubeless and small-bore PCNLs may be superior to other methods. For hospital stay, total tubeless and tubeless PCNLs with stent may be superior to other procedures.

  7. Improved operative efficiency using a real-time MRI-guided stereotactic platform for laser amygdalohippocampotomy.

    PubMed

    Ho, Allen L; Sussman, Eric S; Pendharkar, Arjun V; Le, Scheherazade; Mantovani, Alessandra; Keebaugh, Alaine C; Drover, David R; Grant, Gerald A; Wintermark, Max; Halpern, Casey H

    2018-04-01

    OBJECTIVE MR-guided laser interstitial thermal therapy (MRgLITT) is a minimally invasive method for thermal destruction of benign or malignant tissue that has been used for selective amygdalohippocampal ablation for the treatment of temporal lobe epilepsy. The authors report their initial experience adopting a real-time MRI-guided stereotactic platform that allows for completion of the entire procedure in the MRI suite. METHODS Between October 2014 and May 2016, 17 patients with mesial temporal sclerosis were selected by a multidisciplinary epilepsy board to undergo a selective amygdalohippocampal ablation for temporal lobe epilepsy using MRgLITT. The first 9 patients underwent standard laser ablation in 2 phases (operating room [OR] and MRI suite), whereas the next 8 patients underwent laser ablation entirely in the MRI suite with the ClearPoint platform. A checklist specific to the real-time MRI-guided laser amydalohippocampal ablation was developed and used for each case. For both cohorts, clinical and operative information, including average case times and accuracy data, was collected and analyzed. RESULTS There was a learning curve associated with using this real-time MRI-guided system. However, operative times decreased in a linear fashion, as did total anesthesia time. In fact, the total mean patient procedure time was less in the MRI cohort (362.8 ± 86.6 minutes) than in the OR cohort (456.9 ± 80.7 minutes). The mean anesthesia time was significantly shorter in the MRI cohort (327.2 ± 79.9 minutes) than in the OR cohort (435.8 ± 78.4 minutes, p = 0.02). CONCLUSIONS The real-time MRI platform for MRgLITT can be adopted in an expedient manner. Completion of MRgLITT entirely in the MRI suite may lead to significant advantages in procedural times.

  8. Learning curve analysis of mitral valve repair using telemanipulative technology.

    PubMed

    Charland, Patrick J; Robbins, Tom; Rodriguez, Evilio; Nifong, Wiley L; Chitwood, Randolph W

    2011-08-01

    To determine if the time required to perform mitral valve repairs using telemanipulation technology decreases with experience and how that decrease is influenced by patient and procedure variables. A single-center retrospective review was conducted using perioperative and outcomes data collected contemporaneously on 458 mitral valve repair surgeries using telemanipulative technology. A regression model was constructed to assess learning with this technology and predict total robot time using multiple predictive variables. Statistical analysis was used to determine if models were significantly useful, to rule out correlation between predictor variables, and to identify terms that did not contribute to the prediction of total robot time. We found a statistically significant learning curve (P < .01). The institutional learning percentage∗ derived from total robot times† for the first 458 recorded cases of mitral valve repair using telemanipulative technology is 95% (R(2) = .40). More than one third of the variability in total robot time can be explained through our model using the following variables: type of repair (chordal procedures, ablations, and leaflet resections), band size, use of clips alone in band implantation, and the presence of a fellow at bedside (P < .01). Learning in mitral valve repair surgery using telemanipulative technology occurs at the East Carolina Heart Institute according to a logarithmic curve, with a learning percentage of 95%. From our regression output, we can make an approximate prediction of total robot time using an additive model. These metrics can be used by programs for benchmarking to manage the implementation of this new technology, as well as for capacity planning, scheduling, and capital budget analysis. Copyright © 2011 The American Association for Thoracic Surgery. All rights reserved.

  9. New fixation method for maxillary distraction osteogenesis using locking attachments.

    PubMed

    Suzuki, Eduardo Yugo; Buranastidporn, Boonsiva; Ishii, Masatoshi

    2006-10-01

    The external traction hooks of the intraoral splint used in the rigid external distraction (RED) system for maxillary distraction osteogenesis interfere with the surgical procedures. The purpose of this study is to introduce an innovative splint fixation method for maxillary distraction osteogenesis with Locking Attachments and evaluate their advantages, such as reduction of operating time compared with the traditional intraoral splint method. Retrospective comparison of operative times of maxillary Le Fort I osteotomy procedures was carried out with the traditional protocol using the intraoral splint cemented to the maxillary dentition (n = 14), and a removable intraoral splint that is inserted postsurgically (n = 14). Operative procedure times were compared and analyzed statistically using the data extracted from the surgical records. There were no complications inserting the removable splint postsurgically, including pain, discomfort, or time-consuming procedure. Stable and secure splint fixation was obtained before the distraction procedure and the desired treatment goals were obtained in all patients. The total operative procedure times were significantly reduced in the Locking Attachments group by 24% to 41% (approximately 65 minutes) compared with earlier operations involving the conventional splints (P < .05). Maxillary distraction osteogenesis with the Locking Attachments is a highly effective fixation approach to manage severe hypoplastic maxilla, eliminating lip constraints resulting from scarring and allowing for easier, more deliberate and careful dissection. The use of the Locking Attachments is reliable in craniofacial surgery and has proved to be advantageous in the reduction of the operating time and surgical risks.

  10. Does the Timing of Pre-Operative Medical Evaluation Influence Perioperative Total Hip Arthroplasty Outcomes?

    PubMed

    Lan, Roy H; Kamath, Atul F

    2017-01-01

    Medical evaluation pre-operatively is an important component of risk stratification and potential risk optimization. However, the effect of timing prior to surgical intervention is not well-understood. We hypothesized that total hip arthroplasty (THA) patients seen in pre-operative evaluation closer to the date of surgery would experience better perioperative outcomes. We retrospectively reviewed 167 elective THA patients to study the relationship between the number of days between pre-operative evaluation (range, 0-80 days) and surgical intervention. Patients' demographics, length of stay (LOS), ICU admission frequency, and rate of major complications were recorded. When pre-operative evaluation carried out 4 days or less before the procedure date, there was a significant reduction in LOS (3.91 vs. 4.49; p=0.03). When pre-operative evaluation carried out 11 days or less prior to the procedure date, there was a four-fold decrease in rate of intensive care admission (p=0.04). Furthermore, the major complication rate also significantly reduced (p<0.05). However, when pre-operative evaluation took place 30 days or less before the procedure date compared to more than 30 days prior, there were no significant changes in the outcomes. From this study, pre-operative medical evaluation closer to the procedure date was correlated with improved selected peri-operative outcomes. However, further study on larger patient groups must be done to confirm this finding. More study is needed to define the effect on rare events like infection, and to analyze the subsets of THA patients with modifiable risk factors that may be time-dependent and need further time to optimization.

  11. Remote magnetic with open-irrigated catheter vs. manual navigation for ablation of atrial fibrillation: a systematic review and meta-analysis.

    PubMed

    Proietti, Riccardo; Pecoraro, Valentina; Di Biase, Luigi; Natale, Andrea; Santangeli, Pasquale; Viecca, Maurizio; Sagone, Antonio; Galli, Alessio; Moja, Lorenzo; Tagliabue, Ludovica

    2013-09-01

    The aim of this study was to determine the efficacy and safety of remote magnetic navigation (RMN) with open-irrigated catheter vs. manual catheter navigation (MCN) in performing atrial fibrillation (AF) ablation. We searched in PubMed (1948-2013) and EMBASE (1974-2013) studies comparing RMN with MCN. Outcomes considered were AF recurrence (primary outcome), pulmonary vein isolation (PVI), procedural complications, and data on procedure's performance. Odds ratios (OR) and mean difference (MD) were extracted and pooled using a random-effect model. Confidence in the estimates of the obtained effects (quality of evidence) was assessed using the Grading of Recommendations Assessment, Development and Evaluation approach. We identified seven controlled trials, six non-randomized and one randomized, including a total of 941 patients. Studies were at high risk of bias. No difference was observed between RMN and MCN on AF recurrence [OR 1.18, 95% confidence interval (CI) 0.85 to 1.65, P = 0.32] or PVI (OR 0.41, 95% CI 0.11-1.47, P = 0.17). Remote magnetic navigation was associated with less peri-procedural complications (Peto OR 0.41, 95% CI 0.19-0.88, P = 0.02). Mean fluoroscopy time was reduced in RMN group (-22.22 min; 95% CI -42.48 to -1.96, P = 0.03), although the overall duration of the procedure was longer (60.91 min; 95% CI 31.17 to 90.65, P < 0.0001). In conclusion, RMN is not superior to MCN in achieving freedom from recurrent AF at mid-term follow-up or PVI. The procedure implies less peri-procedural complications, requires a shorter fluoroscopy time but a longer total procedural time. For the low quality of the available evidence, a proper designed randomized controlled trial could turn the direction and the effect of the dimensions explored.

  12. Improved Lung Perfusion After Left Pulmonary Artery Patch Enlargement During the Norwood Operation.

    PubMed

    Salehi Ravesh, Mona; Scheewe, Jens; Attmann, Tim; Al Bulushi, Abdullah; Jussli-Melchers, Marka-Jill; Jerosch-Herold, Michael; Gabbert, Dominik D; Wegner, Philip; Kramer, Hans-Heiner; Rickers, Carsten

    2018-05-01

    Optimal pulmonary perfusion is crucial for a well-functioning Fontan circulation in patients with hypoplastic left heart syndrome (HLHS). To obtain an adequate size of the left pulmonary artery (LPA), patch enlargement is a routine part of the hemi-Fontan procedure in our center. However, LPA patch enlargement at the time of the modified Norwood procedure may have surgical advantages. Therefore, the aim of this study was to evaluate whether anatomic and functional effects of the new approach are superior. A total of 51 consecutive HLHS patients underwent a cardiovascular magnetic resonance imaging study including assessment of LPA anatomy and lung perfusion. The LPA of 20 patients was enlarged during the modified Norwood procedure (group N) and of 31 patients during the hemi-Fontan procedure (group HF). The median indexed cross-sectional area of the LPA in group N was significantly higher than in group HF (49.5 versus 27.9 mm 2 /m 2 , p < 0.0001). The regional pulmonary perfusion as measured by first-pass, contrast-enhanced signal intensity upslope was significantly improved in group N (left side 0.67 s -1 versus 0.40 s -1 , p = 0.002; right side 0.84 s -1 versus 0.52 s -1 , p = 0.01). The total hemi-Fontan bypass and procedure times were significantly shorter in group N (both p < 0.001). These first magnetic resonance imaging data show that HLHS patients after LPA patch enlargement during the modified Norwood procedure have significantly higher LPA cross-sectional areas and show improved lung perfusion and shorter overall procedure time as compared with LPA patching during second stage (hemi-Fontan). Therefore, this promising surgical technique may improve blood flow dynamics of the Fontan circulation in the long run. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Impact of spinal anesthesia for open pyloromyotomy on operating room time.

    PubMed

    Kachko, Ludmyla; Simhi, Eliahu; Freud, Enrique; Dlugy, Elena; Katz, Jacob

    2009-10-01

    When pyloromyotomy for hypertrophic pyloric stenosis (HPS) is performed under general anesthesia, metabolic abnormalities and fluid deficits coupled with residual anesthetics may increase the risk of postoperative apnea, thereby, prolonging operating room time and delaying extubation. Spinal anesthesia has been found to reduce the rate of postoperative apnea in high-risk infants. The aim of the study was to evaluate the effect of spinal vs general anesthesia on operating room time in infants undergoing open pyloromyotomy. Data for 60 infants who underwent pyloromyotomy under spinal (n = 24) or general (n = 36) anesthesia at a tertiary pediatric medical center were derived from the computerized database. Primary outcome measures were total operating room time, procedure duration, anesthesia release time, wake-up time, and anesthesia control time (anesthesia release plus wake-up). Nonparametric Mann-Whitney test was used for statistical analysis, and Levene's test was used to assess the equality of variances in samples; P

  14. "Turn laterally to the left!". The need for uniform C-arm communication terminology during orthopaedic trauma surgery.

    PubMed

    De Muinck Keizer, R-J; Klei, D S; Van Koperen, P J; Van Dijk, C N; Goslings, J C

    2017-03-01

    To avoid disturbed teamwork, unnecessary radiation exposure, and procedural delays, we designed and tested a uniform communication language for use in fluoroscopy-assisted surgical procedures. Input of surgeons and radiographers was used to create a set of commands. The potential benefit of this terminology was explored in an experimental setting. There was a tremendous diversity in the currently used terminology. Use of the newly designed terminology showed a reduction of procedural time and amount of images needed. Our first standardized Dutch language terminology can reduce total fluoroscopy time, number of images acquired, and potentially radiation exposure. For Dutch speaking colleagues, the developed terminology is freely available for use in their OR.

  15. An analysis of leading, lagging, and coincident economic indicators in the United States and its relationship to the volume of plastic surgery procedures performed: an update for 2012.

    PubMed

    Paik, Angie M; Hoppe, Ian C; Pastor, Craig J

    2013-09-01

    As physician compensation and reimbursement tightens throughout the United States, it is important for physicians to be aware of the influence that the economic environment has on the unique medical field of plastic and reconstructive surgery. This study will attempt to determine a relationship between the volume of different plastic surgical procedures and various economic indicators. Information from the American Society of Plastic Surgeons' annual reports on plastic surgery statistics available on the Internet (http://www.plasticsurgery.org/Media/Statistics.html) was collected from the years 2000 through 2011. Yearly economic indicators were collected from readily available Web sites. In terms of the total number of plastic surgery procedures performed, there was a significant positive relationship with GDP, GDP per capita, personal income, consumer price index (CPI) (all), and CPI (medical), and a significant negative relationship with the issuance of new home permits. There was a significant positive relationship with total cosmetic procedures and GDP, GDP per capita, personal income, CPI (all), and CPI (medical), and a significant negative relationship with the issuance of new home permits. There was a significant positive relationship between cosmetic surgical procedures and the issuance of new home permits and the average prime rate charged by banks. There was a significant positive relationship with cosmetic minimally invasive procedures and GDP, GDP per capita, personal income, CPI (all), and CPI (medical), and a significant negative relationship with the issuance of new home permits. There was a significant negative relationship between reconstructive procedures and GDP, GDP per capita, personal income, CPI (all), and CPI (medical). Cosmetic minimally invasive procedures involve less downtime, are generally less expensive than surgical options, and are widely available, making it easier for patients to decide on them quickly during good economic times. Furthermore, it is apparent that plastic surgeons must be proficient at performing minimally invasive cosmetic procedures to maintain a clientele and offer patients a more affordable option during tough economic times. This may lead to further business growth during more favorable economic times.

  16. 'X-ray'-free balloon dilation for totally ultrasound-guided percutaneous nephrolithotomy.

    PubMed

    Zhou, Tie; Chen, Guanghua; Gao, Xiaofeng; Zhang, Wei; Xu, Chuanliang; Li, Lei; Sun, Yinghao

    2015-04-01

    The objective of the study was to evaluate the feasibility and safety of balloon dilation for 'X-ray'-free ultrasound-guided percutaneous nephrolithotomy (PCNL). From January 2012 to December 2012, patients underwent 'X-ray'-free ultrasound-guided PCNL with Amplatz dilator (Group A). From January 2013 to April 2014, patients underwent 'X-ray'-free ultrasound-guided PCNL with balloon dilator (Group B). For balloon dilation, a 10 F fascial dilator was used to dilate the tract. Subsequently, the 6 F nephrostomy balloon (8 mm in diameter) was indwelled along the guidewire with a marked length equal to the dilation depth. Under the monitoring of ultrasound, the location of balloon was secured and disappearance of balloon waist was confirmed when the balloon was inflated at a pressure of 20 atm. A total of 163 patients were involved in this study. Of 81 procedures in Group A, 45 procedures were performed by a senior urologist while 36 procedures by a resident. Of 82 patients in Group B, 47 procedures were performed by the same senior urologist while 35 procedures by another resident. For the senior urologist, there was no statistically significant difference between two groups in calyx of entry, stone-free rate, decline of hemoglobin and hematocrit, operation time and hospitalization. But for the residents, there was less decline of hemoglobin and hematocrit, tract development time and hospitalization in Group B compared to Group A (0.6 vs. 1.7 g/dl, p = 0.001; 2.3% vs. 5.5%, p = 0.003; 10.1 vs. 11.0 min, p = 0.027; 7.8 vs. 13.9 days, p < 0.001). Balloon dilation method introduced in this study is compensable for tract development when 'X-ray'-free ultrasound-guided PCNL is performed. Modified techniques make totally ultrasound guidance for PCNL feasible, easy and safe. In addition, such a procedure is preferable for initial operators because of less hemorrhage complication.

  17. Evaluation of lumbar transforaminal epidural injections with needle placement and contrast flow patterns: a prospective, descriptive report.

    PubMed

    Manchikanti, Laxmaiah; Cash, Kim A; Pampati, Vidyasagar; Damron, Kim S; McManus, Carla D

    2004-04-01

    Transforaminal epidural steroid injection is one of the commonly employed modalities of treatment in managing nerve root pain. However, there have been no controlled prospective evaluations of epidural and nerve root contrast distribution patterns and other aspects of fluoroscopically directed lumbosacral transforaminal epidural steroid injections. To evaluate contrast flow patterns and intravascular needle placement of fluoroscopically guided lumbosacral transforaminal epidural injections. A prospective, observational study. A total of 100 consecutive patients undergoing fluoroscopically guided transforaminal epidural steroid injections were evaluated. The contrast flow patterns, ventral or dorsal epidural filling, nerve root filling, C-arm time, and intravascular needle placement were evaluated. Ventral epidural filling was seen in 88% of the procedures, in contrast to dorsal filling noted in 9% of the procedures. Nerve root filling was seen in 97% of the procedures. Total intravenous placement of the needle was noted in 22% of the procedures, whereas negative flashback and aspiration was noted in 5% of the procedures. Lumbosacral transforaminal epidural injections, performed under fluoroscopic visualization, provide excellent nerve root filling and ventral epidural filling patterns. However, unrecognized intravascular needle placement with negative flashback or aspiration was noted in 5% of the procedures.

  18. Investigation of abort procedures for space shuttle-type vehicles

    NASA Technical Reports Server (NTRS)

    Powell, R. W.; Eide, D. G.

    1974-01-01

    An investigation has been made of abort procedures for space shuttle-type vehicles using a point mass trajectory optimization program known as POST. This study determined the minimum time gap between immediate and once-around safe return to the launch site from a baseline due-East launch trajectory for an alternate space shuttle concept which experiences an instantaneous loss of 25 percent of the total main engine thrust.

  19. Real-time colour pictorial radiation monitoring during coronary angiography: effect on patient peak skin and total dose during coronary angiography.

    PubMed

    Wilson, Sharon M; Prasan, Ananth M; Virdi, Amy; Lassere, Marissa; Ison, Glenn; Ramsay, David R; Weaver, James C

    2016-10-10

    The aim of this study was to evaluate whether a real-time (RT) colour pictorial radiation dose monitoring system reduces patient skin and total radiation dose during coronary angiography and intervention. Patient demographics, procedural variables and radiation parameters were recorded before and after institution of the RT skin dose recording system. Peak skin dose as well as traditionally available measures of procedural radiation dose were compared. A total of 1,077 consecutive patients underwent coronary angiography, of whom 460 also had PCI. Institution of the RT skin dose recording system resulted in a 22% reduction in peak skin dose after accounting for confounding variables. Radiation dose reduction was most pronounced in those having PCI but was also seen over a range of subgroups including those with prior coronary artery bypass surgery, high BMI, and with radial arterial access. This was associated with a significant reduction in the number of patients placed at risk of skin damage. Similar reductions in parameters reflective of total radiation dose were also demonstrated after institution of RT radiation monitoring. Institution of an RT skin dose recording reduced patient peak skin and total radiation dose during coronary angiography and intervention. Consideration should be given to widespread adoption of this technology.

  20. The Barcelona Hospital Clínic therapeutic apheresis database.

    PubMed

    Cid, Joan; Carbassé, Gloria; Cid-Caballero, Marc; López-Púa, Yolanda; Alba, Cristina; Perea, Dolores; Lozano, Miguel

    2017-09-22

    A therapeutic apheresis (TA) database helps to increase knowledge about indications and type of apheresis procedures that are performed in clinical practice. The objective of the present report was to describe the type and number of TA procedures that were performed at our institution in a 10-year period, from 2007 to 2016. The TA electronic database was created by transferring patient data from electronic medical records and consultation forms into a Microsoft Access database developed exclusively for this purpose. Since 2007, prospective data from every TA procedure were entered in the database. A total of 5940 TA procedures were performed: 3762 (63.3%) plasma exchange (PE) procedures, 1096 (18.5%) hematopoietic progenitor cell (HPC) collections, and 1082 (18.2%) TA procedures other than PEs and HPC collections. The overall trend for the time-period was progressive increase in total number of TA procedures performed each year (from 483 TA procedures in 2007 to 822 in 2016). The tracking trend of each procedure during the 10-year period was different: the number of PE and other type of TA procedures increased 22% and 2818%, respectively, and the number of HPC collections decreased 28%. The TA database helped us to increase our knowledge about various indications and type of TA procedures that were performed in our current practice. We also believe that this database could serve as a model that other institutions can use to track service metrics. © 2017 Wiley Periodicals, Inc.

  1. Comparison between two portal laparoscopy and open surgery for ovariectomy in dogs.

    PubMed

    Shariati, Elnaz; Bakhtiari, Jalal; Khalaj, Alireza; Niasari-Naslaji, Amir

    2014-01-01

    Ovariectomy (OVE) is a routine surgical procedure for neutering in small animal practice. Laparoscopy is a new surgical technique which contains advantages such as less trauma, smaller incision and excellent visualization than traditional open surgery. The present study was conducted to examine the feasibility and safety of laparoscopic procedure through two portal comparing with the conventional open surgery for OVE in healthy female bitches (n=16). Dogs were divided in two equal groups. In laparoscopic group, two 5 and 10 mm portals were inserted; First in the umbilicus for introducing the camera and the second, caudal to the umbilicus for inserting the forceps. Laparoscopic procedure involved grasping and tacking the ovary to the abdominal wall, followed by electrocautery, resection and removal of the ovary. In open surgery, routine OVE was conducted through an incision from umbilicus to caudal midline. Mean operative time, total length of scar, blood loss, clinical and blood parameters and all intra and post-operative complications were recorded in both groups. Mean operative time, total length of scar, blood loss and post-operative adhesions were significantly less in laparoscopic group compared with open surgery. In conclusion, laparoscopic OVE is an acceptable procedure due to more advantages in comparison with traditional OVE.

  2. Computer image-guided surgery for total maxillectomy.

    PubMed

    Homma, Akihiro; Saheki, Masahiko; Suzuki, Fumiyuki; Fukuda, Satoshi

    2008-12-01

    In total maxillectomy, the entire upper jaw including the tumor is removed en bloc from the facial skeleton. An intraoperative computed tomographic guidance system (ICTGS) can improve orientation during surgical procedures. However, its efficacy in head and neck surgery remains controversial. This study evaluated the use of an ICTGS in total maxillectomy. Five patients with maxillary sinus neoplasms underwent surgery using a StealthStation ICTGS. The headset was used for anatomic registration during the preoperative CT scan and surgical procedure. The average accuracy was 0.95 mm. The ICTGS provided satisfactory accuracy until the end of resection in all cases, and helped the surgeon to confirm the anatomical location and decide upon the extent of removal in real time. It was particularly useful when the zygoma, maxillary frontal process, orbital floor, and pterygoid process were divided. All patients remained alive and disease free during short-term follow-up. The ICTGS played a supplementary role in total maxillectomy, helping the surgeon to recognize target points accurately in real time, to determine the minimum accurate bone-resection line, and to use the most direct route to reach the lesion. It could also reduce the extent of the skin incision and removal, thus maintaining oncological safety.

  3. Cost identification of abdominal aortic aneurysm imaging by using time and motion analyses.

    PubMed

    Rubin, G D; Armerding, M D; Dake, M D; Napel, S

    2000-04-01

    To compare the costs of performing helical computed tomographic (CT) angiography with three-dimensional rendering versus intraarterial digital subtraction angiography (DSA) for preoperative imaging of abdominal aortic aneurysms (AAAs). A single observer determined the variable direct costs of performing nine intraarterial DSA and 10 CT angiographic examinations in age- and general health-matched patients with AAA by using time and motion analyses. All personnel directly involved in the cases were tracked, and the involvement times were recorded to the nearest minute. All material items used during the procedures were recorded. The cost of labor was determined from personnel reimbursement data, and the cost of materials, from vendor pricing. The variable direct costs of laboratory tests and using the ambulatory treatment unit for postprocedural monitoring, as well as all fixed direct costs, were assessed from hospital accounting records. The total costs were determined for each procedure and compared by using the Student t test and calculating the CIs. The mean total direct cost of intraarterial DSA (+/- SD) was $1,052 +/- 71, and that of CT angiography was $300 +/- 30, which are significantly different (P < 4.1 x 10(-11)). With 95% confidence, intraarterial DSA cost 3.2-3.7 times more than CT angiography for the assessment of AAA. Assuming equal diagnostic utility and procedure-related morbidity, institutions may have substantial cost savings whenever CT angiography can replace intraarterial DSA for imaging AAAs.

  4. Contemporary trends in urinary tract stone surgery, a regional perspective: Auckland, New Zealand.

    PubMed

    Acland, George; Zargar-Shoshtari, Kamran; Rice, Michael

    2016-04-01

    The aim of the study is to assess the contemporary patterns of utilization of various therapeutic options for the management of nephrolithiasis in our tertiary referral institution in Auckland, New Zealand. A retrospective audit was conducted for all urinary stone procedures between January 2007 and December 2013. Procedure-related information was collected for each year. All elective and emergency procedures were included. Data were collected on the elective waiting lists for each procedure. A total of 5512 stone-related cases were performed during the study period. Six hundred and fifty-three cases were performed in 2007 compared with 945 in 2013. Total number of percutaneous nephrolithotomy (PCNLs) performed, as well as the proportion of PCNL cases, demonstrated a significant decline from 84 (12.9%) in 2007 to 67 (7.1%) in 2013. While the annual numbers of extracorporeal shock wave lithotripsy (ESWLs) have increased, the percentage of ESWLs performed relative to total stone procedures has declined from 33% to 23% over the last 4 years of this audit. There has been a significant rise in the numbers of rigid and flexible ureteroscopies, with these now being the most utilized procedure. The number of patients awaiting elective procedures declined over the duration of this audit, with an associated improvement in meeting annual demand for treatment of nephrolithiasis from 78% in 2007 to 91% in 2013. A proportional decline in PCNL and ESWL utilization with a significant increase in flexible and rigid ureteroscopic procedures has been observed over this time and this pattern has been associated with improved adherence to surgical targets despite an increasing number of cases. © 2015 Royal Australasian College of Surgeons.

  5. Current Epidemiology of Revision Total Knee Arthroplasty in the United States.

    PubMed

    Delanois, Ronald E; Mistry, Jaydev B; Gwam, Chukwuweike U; Mohamed, Nequesha S; Choksi, Ujval S; Mont, Michael A

    2017-09-01

    Revision surgery for failed total knee arthroplasty (TKA) continues to pose a substantial burden for the United States healthcare system. The predominant etiology of TKA failure has changed over time and may vary between studies. This report aims to update the current literature on this topic by using a large national database. Specifically, we analyzed: (1) etiologies for revision TKA; (2) frequencies of revision TKA procedures; (3) various demographics including payer type and region; and (4) the length of stay (LOS) and total charges based on type of revision TKA procedure. The Healthcare Cost and Utilization Project (HCUP) National Inpatient Sample (NIS) database was used to identify all revision TKA procedures performed between 2009 and 2013. Clinical, economic, and demographic data were collected and analyzed for 337,597 procedures. Patients were stratified according to etiology of failure, age, sex, race, US census region, and primary payor class. The mean LOS and total charges were also calculated. Infection was the most common etiology for revision TKA (20.4%), closely followed by mechanical loosening (20.3%). The most common revision TKA procedure performed was all component revision (31.3%). Medicare was the primary payor for the greatest proportion of revisions (57.7%). The South census region performed the most revision TKAs (33.2%). The overall mean LOS was 4.5 days, with arthrotomy for removal of prosthesis without replacement procedures accounting for the longest stays (7.8 days). The mean total charge for revision TKAs was $75,028.07. Without appropriate measures in place, the burden of revision TKAs may become overwhelming and pose a strain on providers and institutions. Continued insight into the etiology and epidemiology of revision TKAs may be the principle step towards improving outcomes and mitigating the need for future revisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Per-Oral Endoscopic Myotomy (POEM) After Previous Laparoscopic Heller Myotomy Is Feasible and Safe in a Porcine Model.

    PubMed

    Miles, Luke F; Frelich, Matthew J; Gould, Jon C; Dua, Kulwinder S; Jensen, Eric S; Kastenmeier, Andrew S

    2015-10-01

    We sought to evaluate the feasibility, safety, and difficulty of performing the per-oral endoscopic myotomy (POEM) procedure in the setting of a prior Heller myotomy using a survival porcine model. Four pigs underwent laparoscopic Heller myotomy with Dor partial anterior fundoplication followed by the POEM performed 4 weeks later. Two additional pigs served as controls, undergoing only the POEM. All procedures were completed without complications. The revisional POEM was not significantly more difficult than POEM controls based on procedure time, POEM procedure components, or procedure difficulty scores. Revisional POEM had a longer mean operative time when compared with Heller myotomy (126.0 vs. 83.8 min; P<0.01) but had a lower total difficulty score (28.6 vs. 52.1; P≪0.01). A POEM after previous Heller myotomy is safe and feasible in the porcine model and has potential as an option for patients suffering from recurrent or persistent symptoms after failed surgical myotomy.

  7. Quantifying faculty teaching time in a department of obstetrics and gynecology.

    PubMed

    Emmons, S

    1998-10-01

    The goal of this project was to develop a reproducible system that measures quantity and quality of teaching in unduplicated hours, such that comparisons of teaching activities could be drawn within and across departments. Such a system could be used for allocating teaching monies and for assessing teaching as part of the promotion and tenure process. Various teaching activities, including time spent in clinic, rounds, and doing procedures, were enumerated. The faculty were surveyed about their opinions on the proportion of clinical time spent in teaching. The literature also was reviewed. Based on analysis of the faculty survey and the literature, a series of calculations were developed to divide clinical time among resident teaching, medical student teaching, and patient care. The only input needed was total time spent in the various clinical activities, time spent in didactic activities, and the resident procedure database. This article describes a simple and fair database system to calculate time spent teaching from activities such as clinic, ward rounds, labor and delivery, and surgery. The teaching portfolio database calculates teaching as a proportion of the faculty member's total activities. The end product is a report that provides a reproducible yearly summary of faculty teaching time per activity and per type of learner.

  8. A statistical probe into variability within total ozone time series over Arosa, Switzerland (9.68°E, 46.78°N)

    NASA Astrophysics Data System (ADS)

    Chakraborthy, Parthasarathi; Chattopadhyay, Surajit

    2013-02-01

    Endeavor of the present paper is to investigate the statistical properties of the total ozone concentration time series over Arosa, Switzerland (9.68°E, 46.78°N). For this purpose, different statistical data analysis procedures have been employed for analyzing the mean monthly total ozone concentration data, collected over a period of 40 years (1932-1971), at the above location. Based on the computations on the available data set, the study reports different degrees of variations in different months. The month of July is reported as the month of lowest variability. April and May are found to be the most correlated months with respect to total ozone concentration.

  9. [Robots in general surgery: present and future].

    PubMed

    Galvani, Carlos; Horgan, Santiago

    2005-09-01

    Robotic surgery is an emerging technology. We began to use this technique in 2000, after it was approved by the Food and Drug Administration. Our preliminary experience was satisfactory. We report 4 years' experience of using this technique in our institution. Between August 2000 and December 2004, 399 patients underwent robotic surgery using the Da Vinci system. We performed 110 gastric bypass procedures, 30 Lap band, 59 Heller myotomies, 12 Nissen fundoplications, 6 epiphrenic diverticula, 18 total esophagectomies, 3 esophageal leiomyoma resections, 1 pyloroplasty, 2 gastrojejunostomies, 2 transduodenal sphincteroplasties, 10 adrenalectomies and 145 living-related donor nephrectomies. Operating times for fundoplications and Lap band were longer. After the learning curve, the operating times and morbidity of the remaining procedures were considerably reduced. Robot-assisted surgery allows advanced laparoscopic procedures to be performed with enhanced results given that it reduces the learning curve as measured by operating time and morbidity.

  10. Comparison of Patient Outcomes and Cost of Overlapping Versus Nonoverlapping Spine Surgery.

    PubMed

    Zygourakis, Corinna C; Sizdahkhani, Saman; Keefe, Malla; Lee, Janelle; Chou, Dean; Mummaneni, Praveen V; Ames, Christopher P

    2017-04-01

    Overlapping surgery recently has gained significant media attention, but there are limited data on its safety and efficacy. To date, there has been no analysis of overlapping surgery in the field of spine. Our goal was to compare overlapping versus nonoverlapping spine surgery patient outcomes and cost. A retrospective review was undertaken of 2319 spine surgeries (n = 848 overlapping; 1471 nonoverlapping) performed by 3 neurosurgery attendings from 2012 to 2015 at the University of California San Francisco. Collected variables included patient age, sex, insurance, American Society of Anesthesiology score, severity of illness, risk of mortality, procedure type, surgeon, day of surgery, source of transfer, admission type, overlapping versus nonoverlapping surgery (≥1 minute of overlapping procedure time), Medicare-Severity Diagnosis-Related Group, osteotomy, and presence of another attending/fellow/resident. Univariate, then multivariate mixed-effect models were used to evaluate the effect of the collected variables on the following outcomes: procedure time, estimated blood loss, length of stay, discharge status, 30-day mortality, 30-day unplanned readmission, unplanned return to OR, and total hospital cost. Urgent spine cases were more likely to be done in an overlapping fashion (all P < 0.01). After we adjusted for patient demographics, clinical indicators, and procedure characteristics, overlapping surgeries had longer procedure times (estimate = 26.17; P < 0.001) and lower rates of discharge to home (odds ratio 0.65; P < 0.001), but equivalent rates of 30-day mortality, readmission, return to the operating room, estimated blood loss, length of stay, and total hospital cost (all P = ns). Overlapping spine surgery may be performed safely at our institution, although continued monitoring of patient outcomes is necessary. Overlapping surgery does not lead to greater hospital costs. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Remote magnetic navigation vs. manual navigation for ablation of ventricular tachycardia: a meta-analysis.

    PubMed

    Wu, Y; Li, K-L; Zheng, J; Zhang, C-Y; Liu, X-Y; Cui, Z-M; Yu, Z-M; Wang, R-X; Wang, W

    2015-09-01

    The purpose of this study was to prospectively evaluate the efficacy and safety of remote magnetic navigation (RMN) in comparison with manual catheter navigation (MCN) in performing ventricular tachycardia ablation. An electronic search was performed using PubMed (1948-2013) and EMBASE (1974-2013) studies comparing RMN with MCN which were published prior to 31 December 2013. Outcomes of interest were as follows: acute success, recurrence rate, complications, total procedure and fluoroscopic times. Standard mean difference (SMD) and its 95 % confidence interval (CI) were used for continuous outcomes; odds ratios (OR) were reported for dichotomous variables. Four non-randomised studies, including a total of 328 patients, were identified. RMN was deployed in 191 patients. Acute success and long-term freedom from arrhythmias were not significantly different between the RMN and control groups (OR 1.845, 95 % CI 0.731-4.659, p = 0.195 and OR 0.676, 95 % CI 0.383-1.194, p = 0.177, respectively). RMN was associated with less peri-procedural complications (OR 0.279, 95 % CI 0.092-0.843, p = 0.024). Shorter procedural and fluoroscopy times were achieved (95 % CI -0.487 to -0.035, p = 0.024 and 95 % CI -1.467 to -0.984, p<0.001, respectively). The acute and long-term success rates for VT ablation are equal between RMN and MCN, whereas the RMN-guided procedure can be performed with a lower complication rate and less procedural and fluoroscopic times. More prospective randomised trials will be needed to better evaluate the superior role of RMN for catheter ablation of ventricular tachycardia.

  12. Single-use instruments, cutting blocks, and trials increase efficiency in the operating room during total knee arthroplasty: a prospective comparison of navigated and non-navigated cases.

    PubMed

    Mont, Michael A; McElroy, Mark J; Johnson, Aaron J; Pivec, Robert

    2013-08-01

    The purpose of this prospective controlled trial was to determine if efficiency increases could be achieved in non-navigated and navigated total knee arthroplasties by replacing traditional saws, cutting blocks, and trials with specialized saws and single-use cutting blocks and trials. Various timing metrics during total knee arthroplasty, including operating room preparation times and specific intra-operative times, were measured in 400 procedures performed by eight different surgeons at 6 institutions. Efficiency increases were the result of statistically significant reductions in combined instrument setup and cleanup times as well as in adjusted surgical episode times in navigated total knee arthroplasties. Single-use instruments show promising benefits, but adequate patient follow-up is needed to confirm safety and efficacy before they can be widely adopted. Nevertheless, the authors believe that the use of single-use instruments, cutting guides, and trial implants for total knee arthroplasty will play an increasing role in improving operating room efficiency. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Recovery process and determinants of adverse event occurrence in bronchoscopic procedures performed under general anaesthesia.

    PubMed

    Özden Omaygenç, Derya; Ünal, Nermin; Edipoğlu, Saadet İpek; Barca Şeker, Tuğçe; Özgül, Mehmet Akif; Turan, Demet; Özdemir, Cengiz; Karaca, İbrahim Oğuz; Çetinkaya, Erdoğan

    2018-04-16

    Regarding the fact that rigid bronchoscopy is generally performed under general anaesthesia and this patient subgroup is remarkably morbid, encountering procedure and/or anaesthesia related complications are highly likely. Here, we aimed to assess factors influencing recovery and detect possible determinants of adverse event occurrence during these operations performed in a tertiary referral centre. Eighty-one consecutive ASA I-IV patients were recruited for this investigation. In the operating theatre after induction of anaesthesia and advancement of the device, maintenance was provided with total intravenous anaesthesia. Neuromuscular blockage was invariably administered, and patients were ventilated manually. In addition to preoperative demographic and procedural characteristics, perioperative hemodynamic variables, recovery times and observed adverse events were noted. Basic demographic properties, ASA and Mallampati scores, and procedure specific variables as lesion localization, lesion and procedure type were comparable among groups assembled with reference to event occurrence. Patients who had experienced adverse event had higher heart rates. Recovery times were comparable between Event (-) and Event (+) groups. Relationship of recovery process were individually tested with all variables and only lesion type was detected to have an effect on respiration and extubation times. Among all parameters only procedural time seemed to be associated with adverse event occurrence (mins, 22.9 ± 11.9 vs 41.6 ± 28.8, P < .001). Recovery times related with return of spontaneous respiration were significantly lower in procedures performed for treatment of tumoral diseases in this study and procedure length was determined to be the ultimate factor which had an impact on adverse event occurrence. © 2018 John Wiley & Sons Ltd.

  14. Remote magnetic navigation for catheter ablation of atrioventricular nodal reentrant tachycardia: a systematic review and meta-analysis.

    PubMed

    Shurrab, Mohammed; Danon, Asaf; Crystal, Alexander; Arouny, Banafsheh; Tiong, Irving; Lashevsky, Ilan; Newman, David; Crystal, Eugene

    2013-07-01

    Catheter ablation has become a well-established, first-line therapy for atrioventricular nodal reentrant tachycardia (AVNRT), the most common reentry supraventricular tachycardia in humans. Robotic systems are becoming increasingly common in both complex and simple ablation procedures with presumed potential improvements in procedural efficacy and safety. The authors of this article conducted a systematic review and meta-analysis on the effectiveness and safety of the magnetic navigation system (MNS) in comparison with conventional catheter navigation for AVNRT ablation. An electronic search was performed using Cochrane Central database, Medline, Embase and Web of Knowledge between 2002 and 2012. References were searched manually. Outcomes of interest were: acute and long-term success, complications, total procedure, ablation and fluoroscopic times. Continuous variables were reported as standardized difference in means (SDM); odds ratios (OR) were reported for dichotomous variables. Thirteen studies (seven of which were nonrandomized controlled, four were case series and two were randomized controlled studies) involving 679 adult patients were identified. Twelve studies were based on a single center and one study was multicentral. MNS was deployed in 339 patients. The follow-up period ranged between 75 and 180 days. Acute success and long-term freedom from arrhythmia were not significantly different between MNS and control groups (98 vs 98%, OR: 0.94 [95% CI: 0.21-4.1] and 97 vs 96%, OR: 1.18 [95% CI: 0.35-4.0], respectively). A shorter fluoroscopic time was achieved with MNS; however, this did not reach statistical significance (15 vs 19 min, SDM: -0.26 [95% CI: -0.64-0.12]). Longer total procedure but similar ablation times were noted with MNS (160 vs 148 min, SDM: 3.48 [95% CI: 0.75-6.21] and 4 vs 6 min, SDM: -0.83 [95% CI: -2.19-0.53], respectively). The overall complication rate was similar between both groups (2.7 vs 1.0%, OR: 1.28 [95% CI: 0.33-4.96]). Our data suggest that the usage of MNS results in similar rates of success and complications when compared with conventional manual catheter ablation for AVNRT. MNS had a trend for reduced fluoroscopic time. Longer total procedure time was observed with MNS while the actual ablation time remained similar. Prospective randomized trials will be needed to better evaluate the relative role of MNS for catheter ablation of AVNRT.

  15. Impact of backwashing procedures on deep bed filtration productivity in drinking water treatment.

    PubMed

    Slavik, Irene; Jehmlich, Alexander; Uhl, Wolfgang

    2013-10-15

    Backwash procedures for deep bed filters were evaluated and compared by means of a new integrated approach based on productivity. For this, different backwash procedures were experimentally evaluated by using a pilot plant for direct filtration. A standard backwash mode as applied in practice served as a reference and effluent turbidity was used as the criterion for filter run termination. The backwash water volumes needed, duration of the filter-to-waste period, time out of operation, total volume discharged and filter run-time were determined and used to calculate average filtration velocity and average productivity. Results for filter run-times, filter backwash volumes, and filter-to-waste volumes showed considerable differences between the backwash procedures. Thus, backwash procedures with additional clear flushing phases were characterised by an increased need for backwash water. However, this additional water consumption could not be compensated by savings during filter ripening. Compared to the reference backwash procedure, filter run-times were longer for both single-media and dual-media filters when air scour and air/water flush were optimised with respect to flow rates and the proportion of air and water. This means that drinking water production time is longer and less water is needed for filter bed cleaning. Also, backwashing with additional clear flushing phases resulted in longer filter run-times before turbidity breakthrough. However, regarding the productivity of the filtration process, it was shown that it was almost the same for all of the backwash procedures investigated in this study. Due to this unexpected finding, the relationships between filter bed cleaning, filter ripening and filtration performance were considered and important conclusions and new approaches for process optimisation and resource savings were derived. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Effect of virtual reality training on laparoscopic surgery: randomised controlled trial

    PubMed Central

    Soerensen, Jette L; Grantcharov, Teodor P; Dalsgaard, Torur; Schouenborg, Lars; Ottosen, Christian; Schroeder, Torben V; Ottesen, Bent S

    2009-01-01

    Objective To assess the effect of virtual reality training on an actual laparoscopic operation. Design Prospective randomised controlled and blinded trial. Setting Seven gynaecological departments in the Zeeland region of Denmark. Participants 24 first and second year registrars specialising in gynaecology and obstetrics. Interventions Proficiency based virtual reality simulator training in laparoscopic salpingectomy and standard clinical education (controls). Main outcome measure The main outcome measure was technical performance assessed by two independent observers blinded to trainee and training status using a previously validated general and task specific rating scale. The secondary outcome measure was operation time in minutes. Results The simulator trained group (n=11) reached a median total score of 33 points (interquartile range 32-36 points), equivalent to the experience gained after 20-50 laparoscopic procedures, whereas the control group (n=10) reached a median total score of 23 (22-27) points, equivalent to the experience gained from fewer than five procedures (P<0.001). The median total operation time in the simulator trained group was 12 minutes (interquartile range 10-14 minutes) and in the control group was 24 (20-29) minutes (P<0.001). The observers’ inter-rater agreement was 0.79. Conclusion Skills in laparoscopic surgery can be increased in a clinically relevant manner using proficiency based virtual reality simulator training. The performance level of novices was increased to that of intermediately experienced laparoscopists and operation time was halved. Simulator training should be considered before trainees carry out laparoscopic procedures. Trial registration ClinicalTrials.gov NCT00311792. PMID:19443914

  17. Comparison of Two Foreign Body Retrieval Devices with Adjustable Loops in a Swine Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Konya, Andras

    2006-12-15

    The purpose of the study was to compare two similar foreign body retrieval devices, the Texan{sup TM} (TX) and the Texan LONGhorn{sup TM} (TX-LG), in a swine model. Both devices feature a {<=}30-mm adjustable loop. Capture times and total procedure times for retrieving foreign bodies from the infrarenal aorta, inferior vena cava, and stomach were compared. All attempts with both devices (TX, n = 15; TX-LG, n = 14) were successful. Foreign bodies in the vasculature were captured quickly using both devices (mean {+-} SD, 88 {+-} 106 sec for TX vs 67 {+-} 42 sec for TX-LG) with nomore » significant difference between them. The TX-LG, however, allowed significantly better capture times than the TX in the stomach (p = 0.022), Overall, capture times for the TX-LG were significantly better than for the TX (p = 0.029). There was no significant difference between the total procedure times in any anatomic region. TX-LG performed significantly better than the TX in the stomach and therefore overall. The better torque control and maneuverability of TX-LG resulted in better performance in large anatomic spaces.« less

  18. Advanced real-time multi-display educational system (ARMES): An innovative real-time audiovisual mentoring tool for complex robotic surgery.

    PubMed

    Lee, Joong Ho; Tanaka, Eiji; Woo, Yanghee; Ali, Güner; Son, Taeil; Kim, Hyoung-Il; Hyung, Woo Jin

    2017-12-01

    The recent scientific and technologic advances have profoundly affected the training of surgeons worldwide. We describe a novel intraoperative real-time training module, the Advanced Robotic Multi-display Educational System (ARMES). We created a real-time training module, which can provide a standardized step by step guidance to robotic distal subtotal gastrectomy with D2 lymphadenectomy procedures, ARMES. The short video clips of 20 key steps in the standardized procedure for robotic gastrectomy were created and integrated with TilePro™ software to delivery on da Vinci Surgical Systems (Intuitive Surgical, Sunnyvale, CA). We successfully performed the robotic distal subtotal gastrectomy with D2 lymphadenectomy for patient with gastric cancer employing this new teaching method without any transfer errors or system failures. Using this technique, the total operative time was 197 min and blood loss was 50 mL and there were no intra- or post-operative complications. Our innovative real-time mentoring module, ARMES, enables standardized, systematic guidance during surgical procedures. © 2017 Wiley Periodicals, Inc.

  19. An integer batch scheduling model considering learning, forgetting, and deterioration effects for a single machine to minimize total inventory holding cost

    NASA Astrophysics Data System (ADS)

    Yusriski, R.; Sukoyo; Samadhi, T. M. A. A.; Halim, A. H.

    2018-03-01

    This research deals with a single machine batch scheduling model considering the influenced of learning, forgetting, and machine deterioration effects. The objective of the model is to minimize total inventory holding cost, and the decision variables are the number of batches (N), batch sizes (Q[i], i = 1, 2, .., N) and the sequence of processing the resulting batches. The parts to be processed are received at the right time and the right quantities, and all completed parts must be delivered at a common due date. We propose a heuristic procedure based on the Lagrange method to solve the problem. The effectiveness of the procedure is evaluated by comparing the resulting solution to the optimal solution obtained from the enumeration procedure using the integer composition technique and shows that the average effectiveness is 94%.

  20. New minimally access hydrocelectomy.

    PubMed

    Saber, Aly

    2011-02-01

    To ascertain the acceptability of minimally access hydrocelectomy through a 2-cm incision and the outcome in terms of morbidity reduction and recurrence rate. Although controversy exists regarding the treatment of hydrocele, hydrocelectomy remains the treatment of choice for hydroceles. However, the standard surgical procedures for hydrocele can cause postoperative discomfort and complications. A total of 42 adult patients, aged 18-56 years, underwent hydrocelectomy as an outpatient procedure using a 2-cm scrotal skin incision and excision of only a small disk of the parietal tunica vaginalis. The operative time was 12-18 minutes (mean 15). The outcome measures included patient satisfaction and postoperative complications. This procedure requires minor dissection and minimal manipulation during treatment. It also resulted in no recurrence and minimal complications and required a short operative time. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Robotic general surgery experience: a gradual progress from simple to more complex procedures.

    PubMed

    Al-Naami, M; Anjum, M N; Aldohayan, A; Al-Khayal, K; Alkharji, H

    2013-12-01

    Robotic surgery was introduced at our institution in 2003, and we used a progressive approach advancing from simple to more complex procedures. A retrospective chart review. Cases included totalled 129. Set-up and operative times have improved over time and with experience. Conversion rates to standard laparoscopic or open techniques were 4.7% and 1.6%, respectively. Intraoperative complications (6.2%), blood loss and hospital stay were directly proportional to complexity. There were no mortalities and the postoperative complication rate (13.2%) was within accepted norms. Our findings suggest that robot technology is presently most useful in cases tailored toward its advantages, i.e. those confined to a single space, those that require performance of complex tasks, and re-do procedures. Copyright © 2013 John Wiley & Sons, Ltd.

  2. Early clinical experience with the da Vinci Xi Surgical System in general surgery.

    PubMed

    Hagen, Monika E; Jung, Minoa K; Ris, Frederic; Fakhro, Jassim; Buchs, Nicolas C; Buehler, Leo; Morel, Philippe

    2017-09-01

    The da Vinci Xi Surgical System (Intuitive Surgical Inc., Sunnyvale, CA, USA) has been released in 2014 to facilitate minimally invasive surgery. Novel features are targeted towards facilitating complex multi-quadrant procedures, but data is scarce so far. Perioperative data of patients who underwent robotic general surgery with the da Vinci Xi system within the first 6 month after installation were collected and analyzed. The gastric bypass procedures performed with the da Vinci Xi Surgical System were compared to an equal amount of the last procedures with the da Vinci Si Surgical System. Thirty-one foregut (28 Roux-en-Y gastric bypasses), 6 colorectal procedures and 1 revisional biliary procedure were performed. The mean operating room (OR) time was 221.8 (±69.0) minutes for gastric bypasses and 306.5 (±48.8) for colorectal procedures with mean docking time of 9.4 (±3.8) minutes. The gastric bypass procedure was transitioned from a hybrid to a fully robotic approach. In comparison to the last 28 gastric bypass procedures performed with the da Vinci Si Surgical System, the OR time was comparable (226.9 versus 230.6 min, p = 0.8094), but the docking time significantly longer with the da Vinci Xi Surgical System (8.5 versus 6.1 min, p = 0.0415). All colorectal procedures were performed with a single robotic docking. No intraoperative and two postoperative complications occurred. The da Vinci Xi might facilitate single-setups of totally robotic gastric bypass and colorectal surgeries. However, further comparable research is needed to clearly determine the significance of this latest version of the da Vinci Surgical System.

  3. Whitacre Needle Reduces the Incidence of Intravascular Uptake in Lumbar Transforaminal Epidural Steroid Injections.

    PubMed

    Hong, JiHee; Jung, Sungwon; Chang, Hyuckwon

    2015-01-01

    Transforaminal epidural steroid injection (TFESI) is a commonly used interventional pain management procedures to treat radicular leg pain. Although most reported complications of TFESI are minor, serious morbidity has also been demonstrated including spinal cord infarction, paraplegia, and quadriparesis. Suggested mechanisms include direct vascular injury or intravascular injection of particulate steroid. We compared 2 different needle types, Whitacre and Quincke type needles, with regard to intravascular injection rate with total procedure time and the amount of radiation during lumbar TFESI. Prospective, randomized trial. An interventional pain management practice in South Korea. After Institutional Review Board approval, 149 patients undergoing lumbar TFESI for radicular leg pain were randomly assigned to one of 2 needle groups (Whitacre needle or Quincke type needle). After final confirmation of intravascular injection with digital subtraction angiography, total procedure time and amount of radiation exposure during TFESI were measured. The overall incidence of intravascular injection was 10.4% (28/269). We analyzed the overall incidence of intravascular injection according to the 2 different needle types. The incidence of intravascular injection of the Whitacre needle was 5.4% (8/146), whereas the incidence of intravascular injection of the Quincke needle was 16.2% (20/123). Total procedure time and amount of radiation required to complete the TFESI in the Whitacre and Quincke needle groups was 168.4 ± 57.9 (seconds) and 33.4 ± 15.9 (cGy/cm2), 131.9 ± 46.0 (seconds) and 33.2 ± 15.8 (cGy/cm2), respectively. The physician who performed the TFESI was not blinded to the type of needle for detecting intravascular injection. This study was focused on lumbar TFESI, however, most TFESIs are performed at the L4-5 or L5-S1 level. The Whitacre needle had the benefit of reducing the incidence of intravascular injection with minimal differences in technical difficulties and the amount of radiation exposure during lumbar TFESI.

  4. Introduction of an operating room information management system improved overall operating room efficiency.

    PubMed

    De Deyne, Cathy; Heylen, René

    2004-01-01

    Operating Room (OR) information systems should manage the OR time, assigned to every surgeon, thereby minimizing the sum of costs of unused OR time and minimizing the costs of elective cases performed outside normal allocated OR time (excess OR-time). The aim of this paper is to illustrate how the introduction of an OR information system influenced daily OR activity performance. Since January 2001, we introduced an OR information system with a visual, airport-like, screen as central part, displaying all scheduled OR activity linked in real-time activity with all OR theatres. For the aim of this paper, we compared all data of OR activity for elective abdominal surgery (EAS) for the first half of 2000 compared to the first half of 2001, after the introduction of our information system. In 2000, 764 elective cases were performed, compared to 815 cases in 2001. For both periods, the total OR time allocated to EAS for this 6 months period was 805 h. For 2000, the total duration of OR activity for EAS was 1044 h 50 min (implicating 239 h 50 min over-time), compared to 1127 h 35 min (implicating 322 h 35 min overtime) for 2001. For 2000, we recorded 147 h 20 min excess time (=exceeding the time limits of OR activity and inducing extra costs) and 46h45min unused OR time. For 2001, we recorded 123 h 04 min excess time and 35 h 21 min unused time. In conclusion, in 2001 we recorded an increase in total OR activity for elective abdominal surgery by 7% in number of procedures and by 8% in total duration. However, in 2001 we recorded a decrease in excess time by 16% (123 h 04 min vs 147 h 20 min), which was for a large part due to a 23% decrease in unused OR time in 2001 compared to 2000 (35 h 21min vs 46 h 45 min). Therefore, the introduction of an OR information system, with a real-time visual display of ongoing OR activity, resulted in a increased performance of OR activity, with more OR procedures performed despite less excess time and less extra costs.

  5. Learning curve of hysteroscopic placement of tubal sterilization microinserts in 15 gynecologists in the Netherlands.

    PubMed

    Janse, Juliënne A; Pattij, Thyrza O S; Eijkemans, Marinus J C; Broekmans, Frank J; Veersema, Sebastiaan; Schreuder, Henk W R

    2013-09-01

    To evaluate the learning curve of hysteroscopic placement of tubal sterilization microinserts by gynecologists in the Netherlands. Prospective multicenter study (Canadian Task Force II-2). Ten community (teaching) hospitals in the Netherlands. A total of 631 women who underwent permanent sterilization by tubal microinserts. Hysteroscopic placement of tubal sterilization microinserts performed by 15 gynecologists experienced in performing operative hysteroscopy, starting from their very first placement. Effect of increasing experience in time on procedure time, pain score, successful bilateral placement, and complications. Bilateral successful placement with confirmation of adequate positioning at follow-up evaluation was achieved in 480 (76.1%) patients at first attempt and in 44 (7.0%) at second attempt. Median procedure time was 8.0 minutes (range: 3-40), and 31 (4.9%) patients were lost to follow-up evaluation. Gravidity showed to be a confounding factor and was consequently adjusted for. A learning curve was seen in a statistically significant decrease of procedure time with increasing experience. The decrease in procedure time extended to 11 to 15 cases and was followed by a plateau phase of the subsequent 60 cases. In contrast, pain scores, successful placement, and complication rate appeared not to improve with increasing experience. A learning curve for hysteroscopic tubal sterilization was seen for procedure time, but successful placement, pain score, and complication rate were not clearly influenced by increasing experience. Copyright © 2013 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  6. Advanced laparoscopic bariatric surgery Is safe in general surgery training.

    PubMed

    Kuckelman, John; Bingham, Jason; Barron, Morgan; Lallemand, Michael; Martin, Matthew; Sohn, Vance

    2017-05-01

    Bariatric surgery makes up an increasing percentage of general surgery training. The safety of resident involvement in these complex cases has been questioned. We evaluated patient outcomes in resident performed laparoscopic bariatric procedures. Retrospective review of patients undergoing a laparoscopic bariatric procedure over seven years at a tertiary care single center. Procedures were primarily performed by a general surgery resident and proctored by an attending surgeon. Primary outcomes included operative volume, operative time and leak rate with perioperative outcomes evaluated as secondary outcomes. A total of 1649 bariatric procedures were evaluated. Operations included laparoscopic bypass (690) and laparoscopic sleeve gastrectomy (959). Average operating time was 136 min. Eighteen leaks (0.67%) were identified. Graduating residents performed an average of 89 laparoscopic bariatric cases during their training. There were no significant differences between resident levels with concern to operative time or leak rate (p 0.97 and p = 0.54). General surgery residents can safely perform laparoscopic bariatric surgery. When proctored by a staff surgeon, a resident's level of training does not significantly impact leak rate. Published by Elsevier Inc.

  7. Laparoscopic and abdominal hysterectomy: a cost comparison.

    PubMed

    Tsaltas, J; Magnus, A; Mamers, P M; Lawrence, A S; Lolatgis, N; Healy, D L

    1997-02-17

    To compare the cost of laparoscopically assisted vaginal hysterectomy (LAVH) with that of total abdominal hysterectomy (TAH) under casemix. Retrospective comparison of the costs, operating time and length of hospital stay. The 16 women undergoing consecutive LAVH and 16 age-matched women undergoing TAH between 1 February 1994 and 31 July 1995; all women were public patients undergoing hysterectomy for benign disease. Monash Medical Centre, a large tertiary teaching hospital in Melbourne, Australia, where casemix is used to determine funding and budget allocation. The difference between the costs of the two procedures was not statistically significant (P = 0.5), despite the cost of laparoscopic hysterectomy including that of disposables. The mean operating time for TAH was 86 minutes (95% CI, 65.5-106.5), compared with 120 minutes (95% CI, 100.8-140.5) for LAVH (P < 0.01). The mean length of stay in the TAH group was 5.75 days, compared with 3.25 days in the LAVH group (P < 0.001). In hysterectomy for benign gynaecological disease, the laparoscopic procedure costs the same as the total abdominal procedure. Audit such as this is important in patient management and in guiding hospitals in funding and bed allocation.

  8. Real-time ultrasound-guided spinal anesthesia using the SonixGPS ultrasound guidance system: a feasibility study.

    PubMed

    Niazi, A U; Chin, K J; Jin, R; Chan, V W

    2014-08-01

    Real-time ultrasound-guided neuraxial blockade remains a largely experimental technique. SonixGPS® is a new needle tracking system that displays needle tip position on the ultrasound screen. We investigated if this novel technology might aid performance of real-time ultrasound-guided spinal anesthesia. Twenty patients with body mass index < 35 kg/m(2) undergoing elective total joint arthroplasty under spinal anesthesia were recruited. Patients with previous back surgery and spinal abnormalities were excluded. Following a pre-procedural ultrasound scan, a 17G proprietary needle-sensor assembly was inserted in-plane to the transducer in four patients and out-of-plane in 16 patients. In both approaches, the trajectory of insertion was adjusted in real-time until the needle tip lay just superficial to the ligamentum flavum-dura mater complex. At this point, a 25G 120 mm Whitacre spinal needle was inserted through the 17G SonixGPS® needle. Successful dural puncture was confirmed by backflow of cerebrospinal fluid from the spinal needle. An overall success rate of 14/20 (70%) was seen with two failures (50%) and four failures (25%) in the in-plane and out-of-plane groups respectively. Dural puncture was successful on the first skin puncture in 71% of patients and in a single needle pass in 57% of patients. The median total procedure time was 16.4 and 11.1 min in the in-plane and out-of-plane groups respectively. The SonixGPS® system simplifies real-time ultrasound-guided spinal anesthesia to a large extent, especially the out-of-plane approach. Nevertheless, it remains a complex multi-step procedure that requires time, specialized equipment, and a working knowledge of spinal sonoanatomy. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  9. A single-vendor and a single-buyer integrated inventory model with ordering cost reduction dependent on lead time

    NASA Astrophysics Data System (ADS)

    Vijayashree, M.; Uthayakumar, R.

    2017-09-01

    Lead time is one of the major limits that affect planning at every stage of the supply chain system. In this paper, we study a continuous review inventory model. This paper investigates the ordering cost reductions are dependent on lead time. This study addressed two-echelon supply chain problem consisting of a single vendor and a single buyer. The main contribution of this study is that the integrated total cost of the single vendor and the single buyer integrated system is analyzed by adopting two different (linear and logarithmic) types ordering cost reductions act dependent on lead time. In both cases, we develop effective solution procedures for finding the optimal solution and then illustrative numerical examples are given to illustrate the results. The solution procedure is to determine the optimal solutions of order quantity, ordering cost, lead time and the number of deliveries from the single vendor and the single buyer in one production run, so that the integrated total cost incurred has the minimum value. Ordering cost reduction is the main aspect of the proposed model. A numerical example is given to validate the model. Numerical example solved by using Matlab software. The mathematical model is solved analytically by minimizing the integrated total cost. Furthermore, the sensitivity analysis is included and the numerical examples are given to illustrate the results. The results obtained in this paper are illustrated with the help of numerical examples. The sensitivity of the proposed model has been checked with respect to the various major parameters of the system. Results reveal that the proposed integrated inventory model is more applicable for the supply chain manufacturing system. For each case, an algorithm procedure of finding the optimal solution is developed. Finally, the graphical representation is presented to illustrate the proposed model and also include the computer flowchart in each model.

  10. Premedication with N-acetylcysteine and simethicone improves mucosal visualization during gastroscopy: a randomized, controlled, endoscopist-blinded study.

    PubMed

    Neale, James R; James, Shirley; Callaghan, James; Patel, Praful

    2013-07-01

    Diagnostic gastroscopy provides a unique opportunity to diagnose early oesophagogastric neoplasia; however, intraluminal mucus and bile can obscure mucosal visualization. The aim of this study was to determine whether the use of a premedication solution containing the mucolytic agent N-acetylcysteine and the surfactant simethicone improves mucosal visualization within a UK diagnostic gastroscopy service. A total of 75 consecutive patients were recruited from a single (S.J.) endoscopist's diagnostic gastroscopy list. They were randomized into three treatment groups: (a) standard control=clear fluids only for 6 h, nil by mouth for 2 h; (b) water control=standard control+100 ml sterile water (given 20 min before gastroscopy); and (c) solution=standard control+100 ml investigated solution (20 min before gastroscopy). The endoscopist was blinded to patient preparation. Inadequate mucosal visualization was defined as fluid/mucus during gastroscopy that could not be suctioned and required flushing with water. The volume of flush, the site at which it was used and the total procedure times were recorded. All three groups showed no statistical difference for age, sex ratio, procedure priority or indication. The mean volume of flush required to obtain clear mucosa was significantly less in the solution group compared with the other groups. The mean overall procedure time was also less in the solution group compared with the other groups. Premedication with N-acetylcysteine and simethicone markedly improves mucosal visibility during gastroscopy. It also reduces the time taken for the procedure. This low-cost and well-tolerated intervention may improve detection of early neoplasia.

  11. Real-time navigation system for sentinel lymph node biopsy in breast cancer patients using projection mapping with indocyanine green fluorescence.

    PubMed

    Takada, Masahiro; Takeuchi, Megumi; Suzuki, Eiji; Sato, Fumiaki; Matsumoto, Yoshiaki; Torii, Masae; Kawaguchi-Sakita, Nobuko; Nishino, Hiroto; Seo, Satoru; Hatano, Etsuro; Toi, Masakazu

    2018-05-09

    Inability to visualize indocyanine green fluorescence images in the surgical field limits the application of current near-infrared fluorescence imaging (NIR) systems for real-time navigation during sentinel lymph node (SLN) biopsy in breast cancer patients. The aim of this study was to evaluate the usefulness of the Medical Imaging Projection System (MIPS), which uses active projection mapping, for SLN biopsy. A total of 56 patients (59 procedures) underwent SLN biopsy using the MIPS between March 2016 and November 2017. After SLN biopsy using the MIPS, residual SLNs were removed using a conventional NIR camera and/or radioisotope method. The primary endpoint of this study was identification rate of SLNs using the MIPS. In all procedures, at least one SLN was detected by the MIPS, giving an SLN identification rate of 100% [95% confidence interval (CI) 94-100%]. SLN biopsy was successfully performed without operating lights in all procedures. In total, 3 positive SLNs were excised using MIPS, but were not included in the additional SLNs excised by other methods. The median number of SLNs excised using the MIPS was 3 (range 1-7). Of procedures performed after preoperative systemic therapy, the median number of SLNs excised using the MIPS was 3 (range 2-6). The MIPS is effective in detecting SLNs in patients with breast cancer, providing continuous and accurate projection of fluorescence signals in the surgical field, without need for operating lights, and could be useful in real-time navigation surgery for SLN biopsy.

  12. Impact of operator experience and training strategy on procedural outcomes with leadless pacing: Insights from the Micra Transcatheter Pacing Study.

    PubMed

    El-Chami, Mikhael; Kowal, Robert C; Soejima, Kyoko; Ritter, Philippe; Duray, Gabor Z; Neuzil, Petr; Mont, Lluis; Kypta, Alexander; Sagi, Venkata; Hudnall, John Harrison; Stromberg, Kurt; Reynolds, Dwight

    2017-07-01

    Leadless pacemaker systems have been designed to avoid the need for a pocket and transvenous lead. However, delivery of this therapy requires a new catheter-based procedure. This study evaluates the role of operator experience and different training strategies on procedural outcomes. A total of 726 patients underwent implant attempt with the Micra transcatheter pacing system (TPS; Medtronic, Minneapolis, MN, USA) by 94 operators trained in a teaching laboratory using a simulator, cadaver, and large animal models (lab training) or locally at the hospital with simulator/demo model and proctorship (hospital training). Procedure success, procedure duration, fluoroscopy time, and safety outcomes were compared between training methods and experience (implant case number). The Micra TPS procedure was successful in 99.2% of attempts and did not differ between the 55 operators trained in the lab setting and the 39 operators trained locally at the hospital (P = 0.189). Implant case number was also not a determinant of procedural success (P = 0.456). Each operator performed between one and 55 procedures. Procedure time and fluoroscopy duration decreased by 2.0% (P = 0.002) and 3.2% (P < 0.001) compared to the previous case. Major complication rate and pericardial effusion rate were not associated with case number (P = 0.755 and P = 0.620, respectively). There were no differences in the safety outcomes by training method. Among a large group of operators, implantation success was high regardless of experience. While procedure duration and fluoroscopy times decreased with implant number, complications were low and not associated with case number. Procedure and safety outcomes were similar between distinct training methodologies. © 2017 Wiley Periodicals, Inc.

  13. Analysis of the United States Marine Corps Continuous Process Improvement Program Applied to the Contracting Process at Marine Corps Regional Contracting Office - Southwest

    DTIC Science & Technology

    2007-12-01

    37 3. Poka - yoke ............................................................................................37 4. Systems for...Standard operating procedures • Visual displays for workflow and communication • Total productive maintenance • Poka - yoke techniques to prevent...process step or eliminating non-value-added steps, and reducing the seven common wastes, will decrease the total time of a process. 3. Poka - yoke

  14. Comparison of Battery-Powered and Manual Bone Biopsy Systems for Core Needle Biopsy of Sclerotic Bone Lesions.

    PubMed

    Cohen, Micah G; McMahon, Colm J; Kung, Justin W; Wu, Jim S

    2016-05-01

    The purpose of this study was to compare manual and battery-powered bone biopsy systems for diagnostic yield and procedural factors during core needle biopsy of sclerotic bone lesions. A total of 155 consecutive CT-guided core needle biopsies of sclerotic bone lesions were performed at one institution from January 2006 to November 2014. Before March 2012, lesions were biopsied with manual bone drill systems. After March 2012, most biopsies were performed with a battery-powered system and either noncoaxial or coaxial biopsy needles. Diagnostic yield, crush artifact, CT procedure time, procedure radiation dose, conscious sedation dose, and complications were compared between the manual and battery-powered core needle biopsy systems by Fisher exact test and t test. One-way ANOVA was used for subgroup analysis of the two battery-powered systems for procedure time and radiation dose. The diagnostic yield for all sclerotic lesions was 60.0% (93/155) and was significantly higher with the battery-powered system (73.0% [27/37]) than with the manual systems (55.9% [66/118]) (p = 0.047). There was no significant difference between the two systems in terms of crush artifact, procedure time, radiation dose, conscious sedation administered, or complications. In subgroup analysis, the coaxial battery-powered biopsies had shorter procedure times (p = 0.01) and lower radiation doses (p = 0.002) than the coaxial manual systems, but the noncoaxial battery-powered biopsies had longer average procedure times and higher radiation doses than the coaxial manual systems. In biopsy of sclerotic bone lesions, use of a battery-powered bone drill system improves diagnostic yield over use of a manual system.

  15. Rib-based Distraction Surgery Maintains Total Spine Growth.

    PubMed

    El-Hawary, Ron; Samdani, Amer; Wade, Jennie; Smith, Melissa; Heflin, John A; Klatt, Joshua W; Vitale, Michael G; Smith, John T

    2016-12-01

    For children undergoing treatment of early onset scoliosis (EOS) using spine-based distraction, recently published research would suggest that total spine length (T1-S1) achieved after the initial lengthening procedure decreases with each subsequent lengthening. Our purpose was to evaluate the effect of rib-based distraction on spine growth in children with EOS. This was a retrospective multi-center review of 35 patients treated with rib-based distraction (minimum 5 y follow-up). Radiographs were analyzed at initial implantation and just before each subsequent lengthening. The primary outcome was T1-S1 height, which was also analyzed as: Change in T1-S1 height per lengthening procedure, percent of expected age-based T1-S1 growth per lengthening time interval, percent increase in T1-S1 height as compared with postimplantation total spine height, and percent of expected T1-S1 growth based upon patient age at time of lengthening procedure. Thirty-five patients with a mean age of 2.6 years at initial surgery were studied. Diagnoses included congenital (n=18), syndromic (n=7), idiopathic (n=5), and neuromuscular (n=5). Major Cobb angle was 63.5 degrees and kyphosis was 40.5 degree. Four postoperative time periods were compared: L1 (preoperative first lengthening surgery), L2-L5 (preoperative second lengthening to preoperative fifth lengthening), L6-L10 (preoperative sixth lengthening to preoperative 10th lengthening), L11-L15 (preoperative 11th lengthening to preoperative 15th lengthening). Cobb angle stayed relatively constant for each lengthening period while maximum kyphosis increased. Total spine height was 19.9 cm pre-implantation, 22.1 cm postimplantation, and 28.0 cm by the 15th lengthening (P<0.05). Percent expected T1-S1 growth per lengthening was 62% for L2-L5, 95% for L6-L10, and 52% for L11-L15. As compared with postimplantation spine height, over the course of 15 lengthening procedures, a further 27% increase in spine height was observed. When lengthening procedures were performed when children were under age 5 years, 82% of expected growth was observed; between ages 6 and 10 years, 76% of expected growth was observed; and beyond age 10 years, 14% of expected growth was observed. Patients treated with rib-based distraction surgery had an increase in total spine height from 20 cm preimplantation to 28 cm by the 15th lengthening. They maintained greater than 75% of expected age-matched spine growth until age 10 years and lengthening procedures did not appear to follow a law of diminishing returns. Rib-based distraction is an effective means of maintaining spine growth which is likely beneficial for pulmonary development as compared with the natural history of EOS. Level IV-Therapeutic study, case series.

  16. Comparison of costs of percutaneous transluminal coronary angioplasty and coronary bypass surgery for patients with angina pectoris.

    PubMed

    van den Brand, M; van Halem, C; van den Brink, F; de Feyter, P; Serruys, P; Suryapranata, H; Meeter, K; Bos, E; van Dalen, F J

    1990-08-01

    To determine the costs of a procedure, the total costs of the department that provides the service must be considered and, in addition, the direct cost of the specific procedure. Applying this principle to the cost accounting of angioplasty and bypass surgery results in a direct, i.e. procedural, cost, including the initial hospital stay, of respectively 8694 Dfl and 20,987 Dfl. A review of the follow-up data for the first year after the original intervention revealed a 2% reintervention rate for bypass surgery, while this percentage was 29% for angioplasty. Adding the first year costs involved with reinterventions to the procedural costs results in a 1-year cost of angioplasty and bypass operation of 13,625 Dfl and 21,363 Dfl, respectively. It is concluded that because of reinterventions in the first year, a mark up of 57% on the procedural cost of angioplasty must be added to cover 1-year costs, while for bypass surgery this is only 1%. Nevertheless, the 1-year cost for angioplasty is still 36% less than for bypass surgery. As reinterventions after PTCA may stay considerably higher than for CABG for several years, the mark-up percentages will be substantially higher for longer time spans. This may tend to equalize the total costs of PTCA and CABG over time spans of perhaps 5-8 years. Sufficient data are not available to verify this statement. Clinicians must realize that choosing the most appropriate procedure is not only a matter of medical assessment but also a matter of cost effectiveness. CABG can be seen as an 'investment decision' while PTCA tends to become a decision with characteristics of 'maintenance planning'!

  17. Appraisal of clinical complications after 23,827 oocyte retrievals in a large assisted reproductive technology program.

    PubMed

    Levi-Setti, Paolo Emanuele; Cirillo, Federico; Scolaro, Valeria; Morenghi, Emanuela; Heilbron, Francesca; Girardello, Donatella; Zannoni, Elena; Patrizio, Pasquale

    2018-06-01

    To assess complications encountered after transvaginal oocyte retrieval procedures. Retrospective analysis. University hospital, fertility center. A total of 23,827 consecutive transvaginal oocyte retrieval procedures in 12,615 patients. Oocyte retrieval procedures performed between June 1996 and October 2016. All oocyte retrieval complications. Those requiring hospital admission for at least 24 hours were considered severe. A total of 96 patients (0.76 %) suffered complications, with hospital admission necessary for 71 patients (0.56 %). When calculated per retrieval, the overall complication rate was 0.4%, whereas 0.29% was the admission rate, with an average duration of hospital stay of 2.77 ± 2.5 days. A surgical procedure was necessary for 24 patients (0.1% per retrieval and 0.19% per patient). Multivariate analysis showed a significant correlation between complications and women age, body mass index (BMI), the number oocyte retrieved, and the mean time to complete oocyte retrieval. The incidence of complications was significantly higher for physicians who had performed <250 retrievals compared with those who had completed >250 retrievals (odds ratio 0.63, 95% confidence interval 0.40-0.99). Oocyte retrieval can be considered a safe procedure but is not without risks. The most important, identifiable, risk factors for the occurrence of complications are: [1] high number of oocytes retrieved, [2] a long duration of the procedure and mean time per oocyte retrieved, [3] inexperience of the surgeon, [4] younger patients with a lesser BMI, and [5] history of prior abdominal or pelvic surgery or pelvic inflammatory disease. NCT03282279. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  18. Liver Function Tests Following Irreversible Electroporation of Liver Tumors: Experience in 174 Procedures.

    PubMed

    Froud, Tatiana; Venkat, Shree R; Barbery, Katuzka J; Gunjan, Arora; Narayanan, Govindarajan

    2015-09-01

    Irreversible electroporation (IRE) is a relatively new ablation modality that uses electric currents to cause cell death. It is commonly used to treat primary and secondary liver tumors in patients with normal liver function and preexisting cirrhosis. Retrospective analysis of 205 procedures sought to evaluate changes in liver function after IRE. Liver function tests (LFTs) results before and after IRE were evaluated from 174 procedures in 124 patients. Aspartate aminotransferase, alanine aminotransferase, alkaline phosphatase (ALKP), and total bilirubin levels were analyzed. The study was Health Insurance Portability and Accountability Act compliant and institutional review board approved. Informed consent was waived. Changes in LFT results after IRE were compared with baseline and were followed up over time to see if they resolved. Changes were compared with volume of ablation. The greatest perturbations were in transaminase levels. The levels increased sharply within 24 hours after IRE in 129 (74.1%) procedures to extreme levels (more than 20 times the upper limit of normal in one-third of cases). Resolution occurred in 95% and was demonstrated to have occurred by a mean of approximately 10 weeks, many documented as early as 7 days after procedure. ALKP levels elevated in 10% procedures, was slower to increase, and was less likely to resolve. Total bilirubin level demonstrated 2 different patterns of elevation--early and late--and similar to ALKP, it was more likely to remain elevated. There was no increased risk in patients with cirrhosis or cholangiocarcinoma. There was no correlation of levels with volume of ablation. IRE results in significant abnormalities in LFT results, but in most of the cases, these are self-limiting, do not preclude treatment, and are similar to the changes seen after radiofrequency and cryoablation in the liver. Copyright © 2015. Published by Elsevier Inc.

  19. National trends in anterior cervical fusion procedures.

    PubMed

    Marawar, Satyajit; Girardi, Federico P; Sama, Andrew A; Ma, Yan; Gaber-Baylis, Licia K; Besculides, Melanie C; Memtsoudis, Stavros G

    2010-07-01

    Population-based database analysis. To analyze trends in patient- and healthcare-system-related characteristics, utilization and outcomes associated with anterior cervical spine fusions. Anterior cervical decompression and spine fusion (ACDF) is one of the most commonly performed surgical procedures of the spine. However, few data analyzing trends in patient- and healthcare-system-related characteristics, utilization and outcomes exist. Data from 1990 to 2004 collected in the National Hospital Discharge Survey were accessed. ACDF procedures were identified. Five-year periods of interest (POI) were created for temporal analysis and changes in the prevalence and utilization of this procedure as well as in patient- and healthcare-system-related variables were examined. The changes in the occurrence of procedure-related complications were evaluated. An estimated total of 771,932 discharges after ACDF were identified. Temporally, an almost 8-fold increase in total prevalence was accompanied by a similar increase in utilization (23/100.000 civilians/POI to 157/100.000/civilians/POI). The highest increase in utilization was observed in those > or =65 years (28-fold). Average age increased from 47.2 years to 50.5 years over time. Length of hospital stay decreased from 5.17 days to 2.38 days. Overall procedure-related complication rates decreased from 4.6% to 3.03%. The prevalence of hypertension, diabetes mellitus, hypercholesterolemia, obesity, pulmonary, and coronary artery increased over time among patients undergoing ACDF. Despite limitations inherent to secondary analysis of large databases, we identified a number of significant changes in the utilization, demographics, and outcomes associated with ACDF, which can be used to assess the effect of changes in medical care, direct health care resources, and future research. The effect of the increased prevalence of comorbidities on medical practice remains to be evaluated. Further studies are necessary to evaluate causal relationships.

  20. Facility cost analysis in outpatient plastic surgery: implications for the academic health center.

    PubMed

    Pacella, Salvatore J; Comstock, Matthew C; Kuzon, William M

    2008-04-01

    The authors examined the economic patterns of outpatient aesthetic and reconstructive plastic surgical procedures performed within an academic health center. For fiscal years 2003 and 2004, the University of Michigan Health System's accounting database was queried to identify all outpatient plastic surgery cases (aesthetic and reconstructive) from four surgical facilities. Total facility charges, cost, revenue, and margin were calculated for each case. Contribution margin (total revenue minus variable direct cost) was compared with total case time to determine average contribution margin per operating suite case minute for subsets of aesthetic and reconstructive procedures. A total of 3603 cases (3457 reconstructive and 146 aesthetic) were identified. Payer mix included Blue Cross (36.7 percent), health maintenance organization (28.7 percent), other commercial payers (17.4 percent), Medicare/Medicaid (13.5 percent), and self-pay (3.7 percent). The most profitable cases were reconstructive laser procedures ($66.20; n = 361), scar revision ($36.01; n = 25), and facial trauma ($32.17; n = 64). The least profitable were hand arthroplasty ($13.93; n = 35), arthroscopy ($17.25; n = 15), and breast reduction ($17.46; n = 210). Aesthetic procedures (n = 144) yielded a significantly higher contribution margin per case minute ($24.21) compared with reconstructive procedures ($22.28; n = 3093) (p = 0.01). Plastic surgical cases performed at dedicated ambulatory surgery centers ($28.60; n = 1477) yielded significantly higher contribution margin per case minute compared with those performed at hospital-based facilities ($25.58; n = 2123) (p < 0.01). Use of standardized accounting (contribution margin per case minute) can be a strategically effective method for determining the most profitable and appropriate case mix. Within academic health centers, aesthetic surgery can be a profitable enterprise; dedicated ambulatory surgery centers yield higher profitability.

  1. Two-stage vs single-stage management for concomitant gallstones and common bile duct stones

    PubMed Central

    Lu, Jiong; Cheng, Yao; Xiong, Xian-Ze; Lin, Yi-Xin; Wu, Si-Jia; Cheng, Nan-Sheng

    2012-01-01

    AIM: To evaluate the safety and effectiveness of two-stage vs single-stage management for concomitant gallstones and common bile duct stones. METHODS: Four databases, including PubMed, Embase, the Cochrane Central Register of Controlled Trials and the Science Citation Index up to September 2011, were searched to identify all randomized controlled trials (RCTs). Data were extracted from the studies by two independent reviewers. The primary outcomes were stone clearance from the common bile duct, postoperative morbidity and mortality. The secondary outcomes were conversion to other procedures, number of procedures per patient, length of hospital stay, total operative time, hospitalization charges, patient acceptance and quality of life scores. RESULTS: Seven eligible RCTs [five trials (n = 621) comparing preoperative endoscopic retrograde cholangiopancreatography (ERCP)/endoscopic sphincterotomy (EST) + laparoscopic cholecystectomy (LC) with LC + laparoscopic common bile duct exploration (LCBDE); two trials (n = 166) comparing postoperative ERCP/EST + LC with LC + LCBDE], composed of 787 patients in total, were included in the final analysis. The meta-analysis detected no statistically significant difference between the two groups in stone clearance from the common bile duct [risk ratios (RR) = -0.10, 95% confidence intervals (CI): -0.24 to 0.04, P = 0.17], postoperative morbidity (RR = 0.79, 95% CI: 0.58 to 1.10, P = 0.16), mortality (RR = 2.19, 95% CI: 0.33 to 14.67, P = 0.42), conversion to other procedures (RR = 1.21, 95% CI: 0.54 to 2.70, P = 0.39), length of hospital stay (MD = 0.99, 95% CI: -1.59 to 3.57, P = 0.45), total operative time (MD = 12.14, 95% CI: -1.83 to 26.10, P = 0.09). Two-stage (LC + ERCP/EST) management clearly required more procedures per patient than single-stage (LC + LCBDE) management. CONCLUSION: Single-stage management is equivalent to two-stage management but requires fewer procedures. However, patient’s condition, operator’s expertise and local resources should be taken into account in making treatment decisions. PMID:22791952

  2. Effects of the Length of Stay on the Cost of Total Knee and Total Hip Arthroplasty from 2002 to 2013.

    PubMed

    Molloy, Ilda B; Martin, Brook I; Moschetti, Wayne E; Jevsevar, David S

    2017-03-01

    Utilization of total knee and hip arthroplasty has greatly increased in the past decade in the United States; these are among the most expensive procedures in patients with Medicare. Advances in surgical techniques, anesthesia, and care pathways decrease hospital length of stay. We examined how trends in hospital cost were altered by decreases in length of stay. Procedure, demographic, and economic data were collected on 6.4 million admissions for total knee arthroplasty and 2.8 million admissions for total hip arthroplasty from 2002 to 2013 using the National (Nationwide) Inpatient Sample, a component of the Healthcare Cost and Utilization Project. Trends in mean hospital costs and their association with length of stay were estimated using inflation-adjusted, survey-weighted generalized linear regression models, controlling for patient demographic characteristics and comorbidity. From 2002 to 2013, the length of stay decreased from a mean time of 4.06 to 2.97 days for total knee arthroplasty and from 4.06 to 2.75 days for total hip arthroplasty. During the same time period, the mean hospital cost for total knee arthroplasty increased from $14,988 (95% confidence interval [CI], $14,927 to $15,049) in 2002 to $22,837 (95% CI, $22,765 to $22,910) in 2013 (an overall increase of $7,849 or 52.4%). The mean hospital cost for total hip arthroplasty increased from $15,792 (95% CI, $15,706 to $15,878) in 2002 to $23,650 (95% CI, $23,544 to $23,755) in 2013 (an increase of $7,858 or 49.8%). If length of stay were set at the 2002 mean, the growth in cost for total knee arthroplasty would have been 70.8% instead of 52.4% as observed, and the growth in cost for total hip arthroplasty would have been 67.4% instead of 49.8% as observed. Hospital costs for joint replacement increased from 2002 to 2013, but were attenuated by reducing inpatient length of stay. With demographic characteristics showing an upward trend in the utilization of joint arthroplasty, including a shift toward younger population groups, reduction in length of stay remains an important target for procedure-level cost containment under emerging payment models.

  3. Bariatric Surgery and Endoluminal Procedures: IFSO Worldwide Survey 2014.

    PubMed

    Angrisani, L; Santonicola, A; Iovino, P; Vitiello, A; Zundel, N; Buchwald, H; Scopinaro, N

    2017-09-01

    Several bariatric surgery worldwide surveys have been previously published to illustrate the evolution of bariatric surgery in the last decades. The aim of this survey is to report an updated overview of all bariatric procedures performed in 2014.For the first time, a special section on endoluminal techniques was added. The 2014 International Federation for the Surgery of Obesity and Metabolic Disorders (IFSO) survey form evaluating the number and the type of surgical and endoluminal bariatric procedures was emailed to all IFSO societies. Trend analyses from 2011 to 2014 were also performed. There were 56/60 (93.3%) responders. The total number of bariatric/metabolic procedures performed in 2014 consisted of 579,517 (97.6%) surgical operations and 14,725 (2.4%) endoluminal procedures. The most commonly performed procedure in the world was sleeve gastrectomy (SG) that reached 45.9%, followed by Roux-en-Y gastric bypass (RYGB) (39.6%), and adjustable gastric banding (AGB) (7.4%). The annual percentage changes from 2013 revealed the increase of SG and decrease of RYGB in all the IFSO regions (USA/Canada, Europe, and Asia/Pacific) with the exception of Latin/South America, where SG decreased and RYGB represented the most frequent procedure. There was a further increase in the total number of bariatric/metabolic procedures in 2014 and SG is currently the most frequent surgical procedure in the world. This is the first survey that describes the endoluminal procedures, but the accuracy of provided data should be hopefully improved in the next future. We encourage the creation of further national registries and their continuous updates taking into account all new bariatric procedures including the endoscopic procedures that will obtain increasing importance in the near future.

  4. Simple training tricks for mastering and taming bypass procedures in neurosurgery

    PubMed Central

    Hafez, Ahmad; Raj, Rahul; Lawton, Michael T.; Niemelä, Mika

    2017-01-01

    Background: Neurosurgeons devoted to bypass neurosurgery or revascularization neurosurgery are becoming scarcer. From a practical point of view, “bypass neurosurgeons” are anastomosis makers, vessels technicians, and time-racing repairers of vessel walls. This requires understanding the key features and hidden tricks of bypass surgery. The goal of this paper is to provide simple and inexpensive tricks for taming the art of bypass neurosurgery. Most of these tricks and materials described can be borrowed, donated, or purchased inexpensively. Methods: We performed a review of relevant training materials and recorded videos for training bypass procedures for 3 years between June 2014 and July 2017. In total, 1,300 training bypass procedures were performed, of which 200 procedures were chosen for this paper. Results: A training laboratory bypass procedures is required to enable a neurosurgeon to develop the necessary skills. The important skills for training bypass procedures gained through meticulous practice to be as reflexes are coordination, speed, agility, flexibility, and reaction time. Bypassing requires synchronization between the surgeon's gross movements, fine motoric skills, and mental strength. The suturing rhythm must be timed in a brain–body–hand fashion. Conclusion: Bypass-training is a critical part of neurosurgical training and not for a selected few. Diligent and meticulous training can enable every neurosurgeon to tame the art of bypass neurosurgery. This requires understanding the key features and hidden tricks of bypass surgery, as well as uncountable hours of training. In bypass neurosurgery, quality and time goes hand in hand. PMID:29285411

  5. Minimally invasive video-assisted thyroid surgery: how can we improve the learning curve?

    PubMed

    Castagnola, G; Giulii Cappone, M; Tierno, S M; Mezzetti, G; Centanini, F; Vetrone, I; Bellotti, C

    2012-10-01

    Minimally invasive video-assisted thyroidectomy (MIVAT) is a technically demanding procedure and requires a surgical team skilled in both endocrine and endoscopic surgery. A time consuming learning and training period is mandatory at the beginning of the experience. The aim of our report is to focus some aspects of the learning curve of the surgeon who practices video-assisted thyroid procedures for the first time, through the analysis of our preliminary series of 36 cases. From September 2004 to April 2005 we selected 36 patients for minimally invasive video-assisted surgery of the thyroid. The patients were considered eligible if they presented with a nodule not exceeding 35 mm in maximum diameter; total thyroid volume within normal range; absence of biochemical and echographic signs of thyroiditis. We analyzed surgical results, conversion rate, operating time, post-operative complications, hospital stay, cosmetic outcome of the series. We performed 36 total thyroidectomy. The procedure was successfully carried out in 33/36 cases. Post-operative complications included 3 transient recurrent nerve palsies and 2 transient hypocalcemias; no definitive hypoparathyroidism was registered. All patients were discharged 2 days after operation. The cosmetic result was considered excellent by most patients. Advances in skills and technology have enabled surgeons to reproduce most open surgical techniques with video-assistance or laparoscopically. Training is essential to acquire any new surgical technique and it should be organized in detail to exploit it completely.

  6. Biopsy of CT-Occult Bone Lesions Using Anatomic Landmarks for CT Guidance.

    PubMed

    Hillen, Travis J; Talbert, Robert J; Friedman, Michael V; Long, Jeremiah R; Jennings, Jack W; Wessell, Daniel E; Baker, Jonathan C

    2017-07-01

    The purpose of this study is to evaluate the histopathologic diagnostic yield, sample size, procedural time, and dose-length product (DLP) for the biopsy of CT-occult lesions found at MRI or PET or both. A retrospective review of our radiology information system for biopsies of CT-occult lesions using CT guidance from January 1, 2010, through December 31, 2014, was performed and compared with a selection of CT-guided biopsies of CT-evident bone lesions during the same period. The data were then evaluated for diagnostic yield of histopathologic diagnosis, procedural time, use of sedation medication, DLP, and size of specimens obtained. A total of 30 CT-occult biopsies met the inclusion criteria. Twenty-seven of those biopsies had results that were concordant with the patient's primary histopathologic diagnosis, imaging findings, and clinical course. In the CT-evident lesion group, concordant histopathologic abnormalities were identified in 27 of 30 patients. There was a statistically significant increase in number of samples obtained for the CT-evident lesions compared with CT-occult lesions. There was no statistically significant difference in total specimen length, DLP, number of CT scans, procedural time, or use of sedation medication between the CT-occult and CT-evident biopsy groups. Biopsy of CT-occult lesions using anatomic landmarks achieves diagnostic yields similar to those for CT-guided biopsy of CT-evident lesions.

  7. Guidance and examination by ultrasound versus landmark and radiographic method for placement of subclavian central venous catheters: study protocol for a randomized controlled trial

    PubMed Central

    2014-01-01

    Background Central venous catheters play an important role in patient care. Real-time ultrasound-guided subclavian central venous (SCV) cannulation may reduce the incidence of complications and the time between skin penetration and the aspiration of venous blood into the syringe. Ultrasonic diagnosis of catheter misplacement and pneumothorax related to central venous catheterization is rapid and accurate. It is unclear, however, whether ultrasound real-time guidance and examination can reduce procedure times and complication rates when compared with landmark guidance and radiographic examination for SCV catheterization. Methods/Design The Subclavian Central Venous Catheters Guidance and Examination by UltraSound (SUBGEUS) study is an investigator-initiated single center, randomized, controlled two-arm trial. Three hundred patients undergoing SCV catheter placement will be randomized to ultrasound real-time guidance and examination or landmark guidance and radiographic examination. The primary outcome is the time between the beginning of the procedure and control of the catheter. Secondary outcomes include the times required for the six components of the total procedure, the occurrence of complications (pneumothorax, hemothorax, or misplacement), failure of the technique and occurrence of central venous catheter infections. Discussion The SUBGEUS trial is the first randomized controlled study to investigate whether ultrasound real-time guidance and examination for SCV catheter placement reduces all procedure times and the rate of complications. Trial registration ClinicalTrials.gov Identifier: NCT01888094 PMID:24885789

  8. Complete major amputation of the upper extremity: Early results and initial treatment algorithm.

    PubMed

    Märdian, Sven; Krapohl, Björn D; Roffeis, Jana; Disch, Alexander C; Schaser, Klaus-Dieter; Schwabe, Philipp

    2015-03-01

    Traumatic major amputations of the upper extremity are devastating injuries. These injuries have a profound impact on patient's quality of life and pose a burden on social economy. The aims of the current study were to report about the initial management of isolated traumatic major upper limb amputation from the time of admission to definitive soft tissue closure and to establish a distinct initial management algorithm. We recorded data concerning the initial management of the patient and the amputated body part in the emergency department (ED) (time from admission to the operation, Injury Severity Score [ISS], cold ischemia time from injury to ED, and total cold ischemia time). The duration, amount of surgical procedures, the time to definitive soft tissue coverage, and the choice of flap were part of the documentation. All intraoperative and postoperative complications were recorded. All patients were successfully replanted (time from injury to ED, 59 ± 4 minutes; ISS16; time from admission to operating room 57 ± 10 minutes; total cold ischemia time 203 ± 20 minutes; total number of procedures 7.3 ± 2.5); definitive soft tissue coverage could be achieved 23 ± 14 days after injury. Two thromboembolic complications occurred, which could be treated by embolectomy during revision surgery, and we saw one early infection, which could be successfully managed by serial debridements in our series. The management of complete major amputations of the upper extremity should be reserved for large trauma centers with enough resources concerning technical, structural, and personnel infrastructure to meet the demands of surgical reconstruction as well as the postoperative care. Following a distinct treatment algorithm is mandatory to increase the rate of successful major replantations, thus laying the foundation for promising secondary functional reconstructive efforts. Therapeutic study, level V.

  9. 40 CFR 63.1413 - Compliance demonstration procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... HAP concentration. (iii) For a carbon adsorption system that regenerates the carbon bed directly... organic compound concentration level, adsorption cycle time, number and capacity of carbon beds, type and working capacity of activated carbon used for carbon beds, design total regeneration stream mass or...

  10. SU-C-18C-06: Radiation Dose Reduction in Body Interventional Radiology: Clinical Results Utilizing a New Imaging Acquisition and Processing Platform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kohlbrenner, R; Kolli, KP; Taylor, A

    2014-06-01

    Purpose: To quantify the patient radiation dose reduction achieved during transarterial chemoembolization (TACE) procedures performed in a body interventional radiology suite equipped with the Philips Allura Clarity imaging acquisition and processing platform, compared to TACE procedures performed in the same suite equipped with the Philips Allura Xper platform. Methods: Total fluoroscopy time, cumulative dose area product, and cumulative air kerma were recorded for the first 25 TACE procedures performed to treat hepatocellular carcinoma (HCC) in a Philips body interventional radiology suite equipped with Philips Allura Clarity. The same data were collected for the prior 85 TACE procedures performed to treatmore » HCC in the same suite equipped with Philips Allura Xper. Mean values from these cohorts were compared using two-tailed t tests. Results: Following installation of the Philips Allura Clarity platform, a 42.8% reduction in mean cumulative dose area product (3033.2 versus 1733.6 mGycm∧2, p < 0.0001) and a 31.2% reduction in mean cumulative air kerma (1445.4 versus 994.2 mGy, p < 0.001) was achieved compared to similar procedures performed in the same suite equipped with the Philips Allura Xper platform. Mean total fluoroscopy time was not significantly different between the two cohorts (1679.3 versus 1791.3 seconds, p = 0.41). Conclusion: This study demonstrates a significant patient radiation dose reduction during TACE procedures performed to treat HCC after a body interventional radiology suite was converted to the Philips Allura Clarity platform from the Philips Allura Xper platform. Future work will focus on evaluation of patient dose reduction in a larger cohort of patients across a broader range of procedures and in specific populations, including obese patients and pediatric patients, and comparison of image quality between the two platforms. Funding for this study was provided by Philips Healthcare, with 5% salary support provided to authors K. Pallav Kolli and Robert G. Gould for time devoted to the study. Data acquisition and analysis was performed by the authors independent of the funding source.« less

  11. Application of laparoscopy in the combined surgical procedures of gynecological and digestive disorders in obese women: a retrospective cohort study.

    PubMed

    Wang, Haibo; Zhou, Ailing; Fan, Min; Li, Ping; Qi, Shengwei; Gao, Licai; Li, Xiujuan; Zhao, Jinrong

    2015-04-01

    Laparoscopy surgery has been widely used for many decades and combined laparoscopic procedures have become favorable choices for concomitant pathologies in the abdomen. However, the type of combination procedures and their safety in obese women have not been well elucidated in obese women. Here we retrospectively reported 147 obese women underwent combined laparoscopic gynecological surgery and cholecystectomy/appendicectomy in our hospital from January 2003 to December 2011. Of the total number of patients (n = 147), various laparoscopic gynecological surgeries were combined with laparoscopic cholecystectomy in 93 patients, and were combined with laparoscopic appendectomy in the rest 54 patients. Patients' ages ranged from 24 to 55 years with an average of 33 years. Our results showed that combined procedures caused various operative time and blood loss, with no difference considering the time to resume oral intake and length of hospital stay. Intraoperative complications occurred in a total of 7 patients (4.8%). None of the patients suffered from major complications after laparoscopic surgery, and minor postoperative complications occurred in 30 patients (20.4%). The follow-up period ranged from 6 to 24 months (average, 18.5 months). None of the patients developed complications during follow-up, except that one patient suffered from colporrhagia. Our results further suggest that the combined abdominal laparoscopic procedures of gynecologic and general surgery are safe and economic choices for obese women, and benefit patients in many ways including lesser pain, shorter hospital stays and earlier recovery. Copyright © 2015 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  12. Real-Time MRI-Guided Endovascular Recanalization of Chronic Total Arterial Occlusion in a Swine Model

    PubMed Central

    Raval, Amish N.; Karmarkar, Parag V.; Guttman, Michael A.; Ozturk, Cengizhan; Sampath, Smita; DeSilva, Ranil; Aviles, Ronnier J.; Xu, Minnan; Wright, Victor J.; Schenke, William H.; Kocaturk, Ozgur; Dick, Alexander J.; Raman, Venkatesh K.; Atalar, Ergin; McVeigh, Elliot R.; Lederman, Robert J.

    2006-01-01

    Background Endovascular recanalization (guidewire traversal) of peripheral artery chronic total occlusion (CTO) can be challenging. X-Ray angiography resolves CTO poorly. Virtually “blind” device advancement during X-ray-guided interventions can lead to procedure failure, perforation and hemorrhage. Alternatively, magnetic resonance imaging (MRI) may delineate the artery within the occluded segment to enhance procedural safety and success. We hypothesized that real-time MRI (rtMRI) guided CTO recanalization can be accomplished in an animal model. Methods and Results Carotid artery CTO was created by balloon injury in 19 lipid overfed swine. After 6–8 weeks, two underwent direct necropsy analysis for histology, three underwent primary X-ray-guided CTO recanalization attempts, and the remaining 14 underwent rtMRI-guided recanalization attempts in a 1.5T interventional MRI system. rtMRI intervention used custom CTO catheters and guidewires that incorporated MRI receiver antennae to enhance device visibility. The mean length of the occluded segments was 13.3 ± 1.6cm. rtMRI-guided CTO recanalization was successful in 11/14 swine and only 1/3 swine using X-ray alone. After unsuccessful rtMRI (n = 3), X-ray-guided attempts also were all unsuccessful. Conclusions Recanalization of long CTO is feasible entirely using rtMRI guidance. Low profile clinical-grade devices will be required to translate this experience to humans. Endovascular recanalization of chronic total arterial occlusion (CTO) is challenging under conventional X-ray guidance because devices are advanced almost blindly. MRI can image CTO borders and luminal contents, and could potentially guide these procedures. We test the feasibility of real-time MRI guided wire traversal in a swine model of peripheral artery CTO using custom active MRI catheters. PMID:16490819

  13. Time-dependent density functional theory description of total photoabsorption cross sections

    NASA Astrophysics Data System (ADS)

    Tenorio, Bruno Nunes Cabral; Nascimento, Marco Antonio Chaer; Rocha, Alexandre Braga

    2018-02-01

    The time-dependent version of the density functional theory (TDDFT) has been used to calculate the total photoabsorption cross section of a number of molecules, namely, benzene, pyridine, furan, pyrrole, thiophene, phenol, naphthalene, and anthracene. The discrete electronic pseudo-spectra, obtained in a L2 basis set calculation were used in an analytic continuation procedure to obtain the photoabsorption cross sections. The ammonia molecule was chosen as a model system to compare the results obtained with TDDFT to those obtained with the linear response coupled cluster approach in order to make a link with our previous work and establish benchmarks.

  14. Otolaryngology Service Usage in Children With Cleft Palate.

    PubMed

    Whittemore, Kenneth R; Dargie, Jenna M; Dornan, Briana K; Boudreau, Brian

    2018-05-01

    To determine the usage of otolaryngology services by children with cleft palate at a pediatric tertiary care facility. Retrospective case series. Specialty clinic at a pediatric tertiary care hospital. Children born between January 1, 1999, and December 31, 2002, with the diagnosis of cleft palate or cleft lip and palate. A total of 41 female and 48 male patients were included. Total number of otolaryngology clinic visits and total number of otolaryngologic surgeries (tympanostomy tube placements and other otologic or upper airway procedures). In the first 5 years of life, these children utilized an average of 8.2 otolaryngology clinic visits (SD = 5.0; range: 1-22) and underwent 3.3 tympanostomy tube surgeries (SD = 2.0; range: 0-10). Seventy-three had their first tube placed at the time of palate repair, and 4 at the time of lip repair. Fifty-one (57.3%) required other otologic or upper airway procedures, including tonsillectomy and/or adenoidectomy (27 children), removal of tympanostomy tubes (24 children), tympanomastoidectomy (3 children), and tympanoplasty (14 children). Of the children who underwent other procedures, they underwent a mean of 1.67 (SD = 0.84; range: 1-4) surgeries. Children with cleft palate are at increased risk for eustachian tube dysfunction, frequently utilize otolaryngology care, and typically receive multiple sets of tympanostomy tubes. This study found that children with cleft palate receive on average of approximately 3 sets of tympanostomy tubes, and the majority required another otologic or upper airway surgery.

  15. Single-Incision Laparoscopic Total Colectomy

    PubMed Central

    Ojo, Oluwatosin J.; Carne, David; Guyton, Daniel

    2012-01-01

    Background and Objectives: To present our experience with a single-incision laparoscopic total colectomy, along with a literature review of all published cases on single-incision laparoscopic total colectomy. Methods: A total of 22 cases were published between 2010 and 2011, with our patient being case 23. These procedures were performed in the United States and United Kingdom. Surgical procedures included total colectomy with end ileostomy, proctocolectomy with ileorectal anastomosis, and total proctocolectomy with ileopouch-anal anastomosis. Intraoperative and postoperative data are analyzed. Results: Twenty-two of the 23 cases were performed for benign cases including Crohns, ulcerative colitis, and familial adenomatous polyposis. One case was performed for adenocarcinoma of the cecum. The mean age was 35.3 years (range, 13 to 64), the mean body mass index was 20.1 (range, 19 to 25), mean operative time was 175.9 minutes (range, 139 to 216), mean blood loss was 95.3mL (range, 59 to 200), mean incision length was 2.61cm (range, 2 to 3). Average follow-up was 4.6 months with 2 reported complications. Conclusions: Single-incision laparoscopic total colectomy is feasible and safe in the hands of an experienced surgeon. It has been performed for both benign and malignant cases. It is comparable to the conventional multi-port laparoscopic total colectomy. PMID:22906326

  16. Modified madigan prostatectomy: a procedure preserved prostatic urethra intact.

    PubMed

    Lu, Jun; Ye, Zhangqun; Hu, Weilie

    2005-01-01

    A total of 92 patients with benign prostatic hyperplasia (BPH) were subjected to modified Madigan prostatectomy (MPC) for a much satisfactory effect in open prostatectomy surgery. Exposing anterior prostatic urethra near the bladder neck and conjunct cystotomy modified the MPC procedure. This modified procedure preserved prostatic urethra intact and could also deal with intracystic lesions at the same time. The intact of prostatic urethra was kept completely or largely in 86 cases. The amount of blood loss during modified procedure was less. The mean operative time was 105 min. Seventy patients had been followed up for 3-24 months. The postoperative average Qmax was 19. 2 ml/s. The cystourethrography revealed that the urethra and bladder neck were intact in 10 patients postoperatively. Furthermore, the prostatic urethra was obviously wider after modified MPC. The modified MPC can reduce the occurrence of urethra injury and enlarge the MPC indications. The modified technique is easy to perform with less complications and much satisfactory clinical result.

  17. Oral glucose efficacy on neonate's pain responses at the NICU: A quasi experimental trial of two clinical procedures.

    PubMed

    Matar, Eman M; Arabiat, Diana H; Foster, Mandie J

    2016-11-01

    This research was undertaken with the purpose of testing two research hypotheses regarding the efficacy of 10% oral glucose solution on procedural pain associated with venepuncture and nasopharyngeal suctioning within three neonatal intensive care units (NICU). The hypotheses were formulated from previous conclusions reached by other researchers highlighting the efficacy of sucrose solutions on neonates' pain responses during minor painful procedures. A quasi-experimental trial utilising a time series design with one group was used. Data from a total of 90 neonates included 60 neonates who underwent a venepuncture and 30 neonates who underwent a nasopharyngeal suctioning procedure for clinical purposes. The neonate's pain response for each procedure was scored using the Neonatal Pain Assessment Scale (NPAS) on two separate occasions over three time periods. The pre-procedural score (T 0 ) when the neonate received no sucrose, the inter-procedural score (T 1 ) when the neonate was given 2ml of 10% glucose solution two minutes before the procedure (intervention group) or where oral glucose was withheld (control group) and the post-procedural score (T 2 ) being at the end of the procedure. The results showed the mean NPAS scores in response to venepuncture or nasopharyngeal suctioning were significantly lower in the intervention group than the control group. This showed that oral glucose (10%) had a positive effect on the pain response during venepuncture and nasopharyngeal suctioning procedures. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Carbon Dioxide Versus Air Insufflation for Elective Colonoscopy: A Meta-Analysis and Systematic Review of Randomized Controlled Trials.

    PubMed

    Memon, Muhammed A; Memon, Breda; Yunus, Rossita M; Khan, Shahjahan

    2016-04-01

    The aim of this study was to conduct a meta-analysis and systematic review of randomized controlled trials (RCTs) comparing 2 methods of colonic insufflation for elective colonoscopy, that is, carbon dioxide (CO2) or air, and to evaluate their efficiency, safety, and side effects. Prospective RCTs comparing CO2 versus air insufflation for colonic distension during colonoscopy were selected by searching PubMed, Medline, Embase, Science Citation Index, Current Contents, and the Cochrane Central Register of Controlled Trials published between January 1980 and October 2014. The outcome variables analyzed included procedural and immediate postprocedural pain (during, end, or within 15 min after procedure), early postprocedural pain (between 30 and 120 min), intermediate postprocedural pain (360 min) and late postprocedural pain (720 to 1140 min), cecal/ileal intubation rate, cecal/ileal intubation time, and total colonoscopy examination time. These outcomes were unanimously decided to be important as they influence the practical approach toward patient management within and outside of hospital. Random effects model was used to calculate the effect size of both binary and continuous data. Heterogeneity among the outcome variables of these trials was determined by the Cochran Q statistic and I2 index. The meta-analysis was prepared in accordance with PRISMA guidelines. Twenty-four RCTs totaling 3996 patients (CO2=2017, Air=1979) were analyzed. Statistically significant differences for the pooled effect size were observed for procedural and immediate postprocedural pain [weighted mean difference (WMD)=0.49; 95% confidence interval (CI), 0.32, 0.73; P=0.0005], early postprocedural pain between 30 and 120 minutes (WMD=0.25; 95% CI, 0.12, 0.49; P<0.0001), intermediate postprocedural pain, that is, 360 minutes after completion (WMD=0.35; 95% CI, 0.23, 0.52; P<0.0001), and late postprocedural pain between 720 and 1440 minutes (WMD=0.53; 95% CI, 0.34, 0.84; P=0.0061). Comparable effects were noted for cecal/ileal intubation rate (WMD=0.86; 95% CI, 0.61, 1.22; P=0.3975), cecal/ileal intubation time (WMD=-0.64; 95% CI, -1.38, 0.09; P=0.0860), and total examination time (WMD=-0.20; 95% CI, -0.96, 0.57; P=0.6133). On the basis of our meta-analysis and systematic review, we conclude that CO2 insufflation significantly reduces abdominal pain during and following the procedure lasting up to 24 hours. There is no difference in the cecal/ileal intubation rate and time and total examination time between the 2 methods. CO2 retention with CO2 insufflation during and after the colonoscopy shows inconsequential variation compared with air insufflation and has no adverse effect on patients. CO2 instead of air should be routinely utilized for colonoscopy.

  19. Generation of an incident focused light pulse in FDTD.

    PubMed

    Capoğlu, Ilker R; Taflove, Allen; Backman, Vadim

    2008-11-10

    A straightforward procedure is described for accurately creating an incident focused light pulse in the 3-D finite-difference time-domain (FDTD) electromagnetic simulation of the image space of an aplanatic converging lens. In this procedure, the focused light pulse is approximated by a finite sum of plane waves, and each plane wave is introduced into the FDTD simulation grid using the total-field/scattered-field (TF/SF) approach. The accuracy of our results is demonstrated by comparison with exact theoretical formulas.

  20. Generation of an incident focused light pulse in FDTD

    PubMed Central

    Çapoğlu, İlker R.; Taflove, Allen; Backman, Vadim

    2009-01-01

    A straightforward procedure is described for accurately creating an incident focused light pulse in the 3-D finite-difference time-domain (FDTD) electromagnetic simulation of the image space of an aplanatic converging lens. In this procedure, the focused light pulse is approximated by a finite sum of plane waves, and each plane wave is introduced into the FDTD simulation grid using the total-field/scattered-field (TF/SF) approach. The accuracy of our results is demonstrated by comparison with exact theoretical formulas. PMID:19582013

  1. Demonstration of the Safety and Feasibility of Robotically Assisted Percutaneous Coronary Intervention in Complex Coronary Lesions: Results of the CORA-PCI Study (Complex Robotically Assisted Percutaneous Coronary Intervention).

    PubMed

    Mahmud, Ehtisham; Naghi, Jesse; Ang, Lawrence; Harrison, Jonathan; Behnamfar, Omid; Pourdjabbar, Ali; Reeves, Ryan; Patel, Mitul

    2017-07-10

    The aims of this study were to evaluate the feasibility and technical success of robotically assisted percutaneous coronary intervention (R-PCI) for the treatment of coronary artery disease (CAD) in clinical practice, especially in complex lesions, and to determine the safety and clinical success of R-PCI compared with manual percutaneous coronary intervention (M-PCI). R-PCI is safe and feasible for simple coronary lesions. The utility of R-PCI for complex coronary lesions is unknown. All consecutive PCI procedures performed robotically (study group) or manually (control group) over 18 months were included. R-PCI technical success, defined as the completion of the procedure robotically or with partial manual assistance and without a major adverse cardiovascular event, was determined. Procedures ineligible for R-PCI (i.e., atherectomy, planned 2-stent strategy for bifurcation lesion, chronic total occlusion requiring hybrid approach) were excluded for analysis from the M-PCI group. Clinical success, defined as completion of the PCI procedure without a major adverse cardiovascular event, procedure time, stent use, and fluoroscopy time were compared between groups. A total of 315 patients (mean age 67.7 ± 11.8 years; 78% men) underwent 334 PCI procedures (108 R-PCIs, 157 lesions, 78.3% type B2/C; 226 M-PCIs, 336 lesions, 68.8% type B2/C). Technical success with R-PCI was 91.7% (rate of manual assistance 11.1%, rate of manual conversion 7.4%, rate of major adverse cardiovascular events 0.93%). Clinical success (99.1% with R-PCI vs. 99.1% with M-PCI; p = 1.00), stent use (stents per procedure 1.59 ± 0.79 with R-PCI vs. 1.54 ± 0.75 with M-PCI; p = 0.73), and fluoroscopy time (18.2 ± 10.4 min with R-PCI vs. 19.2 ± 11.4 min with M-PCI; p = 0.39) were similar between the groups, although procedure time was longer in the R-PCI group (44:30 ± 26:04 min:s vs. 36:34 ± 23:03 min:s; p = 0.002). Propensity-matched analysis confirmed that procedure time was longer in the robotic group (42:59 ± 26:14 min:s with R-PCI vs. 34:01 ± 17:14 min:s with M-PCI; p = 0.007), although clinical success remained similar (98.8% with R-PCI vs. 100% with M-PCI; p = 1.00). This study demonstrates the feasibility, safety, and high technical success of R-PCI for the treatment of complex coronary disease. Furthermore, comparable clinical outcomes, without an adverse effect on stent use or fluoroscopy time, were observed with R-PCI and M-PCI. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  2. Clinical impact of an open-irrigated radiofrequency catheter with direct force measurement on atrial fibrillation ablation.

    PubMed

    Martinek, Martin; Lemes, Christine; Sigmund, Elisabeth; Derndorfer, Michael; Aichinger, Josef; Winter, Siegmund; Nesser, Hans-Joachim; Pürerfellner, Helmut

    2012-11-01

    Electrode-tissue contact is crucial for adequate lesion formation in radiofrequency catheter ablation (RFCA). We assessed the impact of direct catheter force measurement on acute procedural parameters during RFCA of atrial fibrillation (AF). Fifty consecutive patients (28 male) with paroxysmal AF who underwent their first procedure of circumferential pulmonary vein (PV) isolation (PVI) were assigned to either RFCA using (1) a standard 3.5-mm open-irrigated-tip catheter or (2) a catheter with contact force measurement capabilities. Using the endpoint of PVI with entry and exit block, acute procedural parameters were assessed. Procedural data showed a remarkable decline in ablation time (radiofrequency time needed for PVI) from 50.5 ± 15.9 to 39.0 ± 11.0 minutes (P = 0.007) with a reduction in overall procedure duration from 185 ± 46 to 154 ± 39 minutes (P = 0.022). In parallel, the total energy delivered could be significantly reduced from 70,926 ± 19,470 to 58,511 ± 14,655 Ws (P = 0.019). The number of acute PV reconnections declined from 36% to 12% (P = 0.095). The use of contact force sensing technology is able to significantly reduce ablation and procedure times in PVI. In addition, energy delivery is substantially reduced by avoiding radiofrequency ablation in positions with insufficient surface contact. Procedural efficacy and safety of this new feature have to be evaluated in larger cohorts. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  3. Costing imaging procedures.

    PubMed

    Bretland, P M

    1988-01-01

    The existing National Health Service financial system makes comprehensive costing of any service very difficult. A method of costing using modern commercial methods has been devised, classifying costs into variable, semi-variable and fixed and using the principle of overhead absorption for expenditure not readily allocated to individual procedures. It proved possible to establish a cost spectrum over the financial year 1984-85. The cheapest examinations were plain radiographs outside normal working hours, followed by plain radiographs, ultrasound, special procedures, fluoroscopy, nuclear medicine, angiography and angiographic interventional procedures in normal working hours. This differs from some published figures, particularly those in the Körner report. There was some overlap between fluoroscopic interventional and the cheaper nuclear medicine procedures, and between some of the more expensive nuclear medicine procedures and the cheaper angiographic ones. Only angiographic and the few more expensive nuclear medicine procedures exceed the cost of the inpatient day. The total cost of the imaging service to the district was about 4% of total hospital expenditure. It is shown that where more procedures are undertaken, the semi-variable and fixed (including capital) elements of the cost decrease (and vice versa) so that careful study is required to assess the value of proposed economies. The method is initially time-consuming and requires a computer system with 512 Kb of memory, but once the basic costing system is established in a department, detailed financial monitoring should become practicable. The necessity for a standard comprehensive costing procedure of this nature, based on sound cost accounting principles, appears inescapable, particularly in view of its potential application to management budgeting.

  4. How-to-Do-It: A Practical Method for Teaching Seed Stratification.

    ERIC Educational Resources Information Center

    Englert, Karen M.; Shontz, Nancy N.

    1989-01-01

    Described is a laboratory procedure for teaching seed stratification. Materials, methods, results, and applicability of the experiment are explained. Diagrams showing the percent of total germination as a function of stratification time and the germination rate of stratified seeds are included. (RT)

  5. The combined use of Green-Ampt model and Curve Number method as an empirical tool for loss estimation

    NASA Astrophysics Data System (ADS)

    Petroselli, A.; Grimaldi, S.; Romano, N.

    2012-12-01

    The Soil Conservation Service - Curve Number (SCS-CN) method is a popular rainfall-runoff model widely used to estimate losses and direct runoff from a given rainfall event, but its use is not appropriate at sub-daily time resolution. To overcome this drawback, a mixed procedure, referred to as CN4GA (Curve Number for Green-Ampt), was recently developed including the Green-Ampt (GA) infiltration model and aiming to distribute in time the information provided by the SCS-CN method. The main concept of the proposed mixed procedure is to use the initial abstraction and the total volume given by the SCS-CN to calibrate the Green-Ampt soil hydraulic conductivity parameter. The procedure is here applied on a real case study and a sensitivity analysis concerning the remaining parameters is presented; results show that CN4GA approach is an ideal candidate for the rainfall excess analysis at sub-daily time resolution, in particular for ungauged basin lacking of discharge observations.

  6. Forest inventory using multistage sampling with probability proportional to size. [Brazil

    NASA Technical Reports Server (NTRS)

    Parada, N. D. J. (Principal Investigator); Lee, D. C. L.; Hernandezfilho, P.; Shimabukuro, Y. E.; Deassis, O. R.; Demedeiros, J. S.

    1984-01-01

    A multistage sampling technique, with probability proportional to size, for forest volume inventory using remote sensing data is developed and evaluated. The study area is located in the Southeastern Brazil. The LANDSAT 4 digital data of the study area are used in the first stage for automatic classification of reforested areas. Four classes of pine and eucalypt with different tree volumes are classified utilizing a maximum likelihood classification algorithm. Color infrared aerial photographs are utilized in the second stage of sampling. In the third state (ground level) the time volume of each class is determined. The total time volume of each class is expanded through a statistical procedure taking into account all the three stages of sampling. This procedure results in an accurate time volume estimate with a smaller number of aerial photographs and reduced time in field work.

  7. Beef, chicken and lamb fatty acid analysis--a simplified direct bimethylation procedure using freeze-dried material.

    PubMed

    Lee, M R F; Tweed, J K S; Kim, E J; Scollan, N D

    2012-12-01

    When fractionation of meat lipids is not required, procedures such as saponification can be used to extract total fatty acids, reducing reliance on toxic organic compounds. However, saponification of muscle fatty acids is laborious, and requires extended heating times, and a second methylation step to convert the extracted fatty acids to fatty acid methyl esters prior to gas chromatography. Therefore the development of a more rapid direct methylation procedure would be of merit. The use of freeze-dried material for analysis is common and allows for greater homogenisation of the sample. The present study investigated the potential of using freeze-dried muscle samples and a direct bimethylation to analyse total fatty acids of meat (beef, chicken and lamb) in comparison with a saponification procedure followed by bimethylation. Both methods compared favourably for all major fatty acids measured. There was a minor difference in relation to the C18:1 trans 10 isomer with a greater (P<0.05) recovery with saponification. However, numerically the difference was small and likely as a result of approaching the limits of isomer identification by single column gas chromatography. Differences (P<0.001) between species were found for all fatty acids measured with no interaction effects. The described technique offers a simplified, quick and reliable alternative to saponification to analyse total fatty acids from muscle samples. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Extracorporeal Membrane Oxygenation Outcomes After the Comprehensive Stage II Procedure in Patients With Single Ventricles.

    PubMed

    Gomez, Daniel; Duffy, Vicky; Hersey, Diane; Backes, Carl; Rycus, Peter; McConnell, Patrick; Voss, Jordan; Galantowicz, Mark; Cua, Clifford L

    2017-01-01

    Outcomes for extracorporeal membrane oxygenation (ECMO) have been described for patients with single ventricle physiology (SVP) undergoing cavopulmonary connection (Glenn procedure). An alternative surgical pathway for patients with SVP consists of an initial hybrid procedure followed by a comprehensive Stage II procedure. No data exist describing the outcomes of patients requiring ECMO after the comprehensive Stage II procedure. The goal of this study is to describe the outcomes for patients who required ECMO after the comprehensive Stage II procedure. Data from the Extracorporeal Life Support Organization (ELSO) registry from 2001 to 2015 for children undergoing the comprehensive Stage II procedure older than 3 months of age were retrospectively analyzed. Demographics and ECMO characteristics were recorded. A total of six children required ECMO support after the comprehensive Stage II procedure (2 males, 4 females). Four patients had the diagnosis of hypoplastic left heart syndrome and two patients had the diagnosis of an unbalanced atrioventricular septal defect. Bypass time was 242.8 ± 110.9 min and cross-clamp time was 91.2 ± 46.2 min for the surgical procedure. Weight was 5.8 ± 1.3 kg and age was 150.2 + 37.9 days at time of ECMO. ECMO duration was 276.0 ± 218.1 h. Complications during the ECMO run included hemorrhage in four patients (67%), renal dysfunction in two patients (33%), and neurologic injury in two patients (33%). Four patients (67%) were discharged alive after ECMO decannulation. Despite being a much more extensive surgical procedure, the morbidity and mortality after ECMO in patients undergoing the comprehensive Stage II procedure are similar to those in patients undergoing the Glenn procedure. If needed, ECMO support is reasonable for patients after the comprehensive Stage II procedure. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  9. Change of practice patterns in urology with the introduction of the Da Vinci surgical system: the Greek NHS experience in debt crisis era.

    PubMed

    Deligiannis, Dimitros; Anastasiou, Ioannis; Mygdalis, Vasileios; Fragkiadis, Evangelos; Stravodimos, Konstantinos

    2015-03-31

    To determine the attitudinal change for urologic surgery in Greece since the introduction of the da Vinci Surgical System (DVS). We describe contemporary trends at public hospital level, the initial Greek experience, while at the same time Greece is in economic crisis and funding is under austerity measures. We retrospectively analyzed annualized case log data on urologic procedures, between 2008 (installation of the DVS) and 2013, from "Laiko'' Hospital in Athens. We evaluated, using summary statistics, trends and institutional status regarding robot-assisted surgery (RAS). We also analyzed the relationship between the introduction of RAS and change in total volume of procedures performed. 1578 of the urological procedures performed at "Laiko'' Hospital were pooled, 1342 (85%) being open and 236 RAS (15%). We observed a 6-fold increase in the number of RAS performed, from 7% of the total procedural volume (14/212) in 2008 to 30% (96/331) in 2013. For radical prostatectomy, in 2008 2% were robot-assisted and 98% open while in 2013, 46% and 54% respectively. Pyeloplasty was performed more often using the robot-assisted method since 2010. RAS-dedicated surgeons increased both RAS and the total number of procedures they performed. From 86 in 2008 to 145 in 2013, with 57% of them being RAS in 2013 as compared to 13 % in 2008. Robot-assisted surgery has integrated into the armamentarium for urologic surgery in Greece at public hospital level. Surgical robot acquisition is also associated with increased volume of procedures, especially prostatectomy, despite the ongoing debate over cost-effectiveness, during economic crisis and International Monetary Fund (IFN) era.

  10. Cost Analysis of Flexible Ureteroscope Repairs: Evaluation of 655 Procedures in a Community-Based Practice.

    PubMed

    Kramolowsky, Eugene; McDowell, Zachary; Moore, Blake; Booth, Brigette; Wood, Nada

    2016-03-01

    The frequency of flexible ureteroscopy has increased with the introduction of improved instrumentation. Ureteroscopes allow increased endoscopic access to the ureter and kidney. However, maintenance and repair of scopes may increase the total procedure expense. In 3 years (8/2011-7/2014), 655 flexible ureteroscopies were performed at a single-specialty, urology, ambulatory surgery center. Procedures were performed by 26 board-certified urologists using four Olympus URF P5 flexible ureteroscopes. The instruments were handled by a single team and sterilized through the STERIS System E1. Repairs were performed by the manufacturer on an as needed basis. Patient records were reviewed to determine the preoperative diagnosis, operative time, location and size of the stone, and use of laser or ureteral sheath. The occurrence, nature of flexible ureteroscope damage, and cost of repairs were evaluated. Of the ureteroscopies performed, 78% was for the treatment of calculi (50.1% in the kidney). Mean stone size was 8.5 ± 0.2 mm, with larger stones (11 mm) located in the kidney. The flexible ureteroscope was advanced over a guidewire (88% of cases); a laser fiber was introduced in 70%, and a ureteral sheath was used in 13.4%. Mean procedure time was 40 minutes. The most common reasons for ureteroscope repair were cloudy lens (16 repairs) and broken optic fibers (9 repairs). There were 31 repairs during the study period (average 21 cases per repair). Flexible ureteroscopes were out of service for an average of 11 days per repair (range 3-20). The total cost of repairs was $233,150 or ∼$7521 per repair. The average repair cost per flexible ureteroscopy performed was $355. Expenses associated with instrument repair can significantly impact a procedure's net revenue, thus efforts should be made to minimize instrument breakage. The expense of repairing a flexible ureteroscope per procedure can be significant and needs to be considered when pricing this procedure.

  11. Large Variability in the Diversity of Physiologically Complex Surgical Procedures Exists Nationwide Among All Hospitals Including Among Large Teaching Hospitals.

    PubMed

    Dexter, Franklin; Epstein, Richard H; Thenuwara, Kokila; Lubarsky, David A

    2017-11-22

    Multiple previous studies have shown that having a large diversity of procedures has a substantial impact on quality management of hospital surgical suites. At hospitals with substantial diversity, unless sophisticated statistical methods suitable for rare events are used, anesthesiologists working in surgical suites will have inaccurate predictions of surgical blood usage, case durations, cost accounting and price transparency, times remaining in late running cases, and use of intraoperative equipment. What is unknown is whether large diversity is a feature of only a few very unique set of hospitals nationwide (eg, the largest hospitals in each state or province). The 2013 United States Nationwide Readmissions Database was used to study heterogeneity among 1981 hospitals in their diversities of physiologically complex surgical procedures (ie, the procedure codes). The diversity of surgical procedures performed at each hospital was quantified using a summary measure, the number of different physiologically complex surgical procedures commonly performed at the hospital (ie, 1/Herfindahl). A total of 53.9% of all hospitals commonly performed <10 physiologically complex procedures (lower 99% confidence limit [CL], 51.3%). A total of 14.2% (lower 99% CL, 12.4%) of hospitals had >3-fold larger diversity (ie, >30 commonly performed physiologically complex procedures). Larger hospitals had greater diversity than the small- and medium-sized hospitals (P < .0001). Teaching hospitals had greater diversity than did the rural and urban nonteaching hospitals (P < .0001). A total of 80.0% of the 170 large teaching hospitals commonly performed >30 procedures (lower 99% CL, 71.9% of hospitals). However, there was considerable variability among the large teaching hospitals in their diversity (interquartile range of the numbers of commonly performed physiologically complex procedures = 19.3; lower 99% CL, 12.8 procedures). The diversity of procedures represents a substantive differentiator among hospitals. Thus, the usefulness of statistical methods for operating room management should be expected to be heterogeneous among hospitals. Our results also show that "large teaching hospital" alone is an insufficient description for accurate prediction of the extent to which a hospital sustains the operational and financial consequences of performing a wide diversity of surgical procedures. Future research can evaluate the extent to which hospitals with very large diversity are indispensable in their catchment area.

  12. A Documentation System to Save Time and Ensure Proper Application of the Fiberoptic Endoscopic Evaluation of Swallowing (FEES®)

    PubMed Central

    Hey, Christiane; Pluschinski, Petra; Stanschus, Soenke; Euler, Harald A.; Sader, Robert A.; Langmore, Susan; Neumann, Katrin

    2011-01-01

    A properly performed fiberoptic endoscopic evaluation of swallowing (FEES®) is comprehensive and time-consuming. Editing times of FEES protocols and attempts for efficiency maximization are unknown. Here, the protocol editing times of completed FEES examinations were determined. The present study reports the time savings and quality gains of a newly developed documentation system tailored to the FEES standard of Langmore. Four independent examiners analyzed twelve videos of FEES procedures, six without and six with the documentation system. Effectiveness of the documentation system was evaluated according to the times for total evaluation, interpretation, documentation, report writing, and for report completeness. The documentation system reduced editing times and increased report completeness with large effect sizes. Averaged total evaluation time decreased from 42 to 27 min, report completeness increased from 55 to 80%. The use of the documentation system facilitates and improves the assessment of the swallowing process. PMID:20938202

  13. Throughput times for adults and children during two drive-through influenza vaccination clinics.

    PubMed

    Banks, Laura L; Crandall, Cameron; Esquibel, Luke

    2013-04-01

    Successful planning for public health emergencies requires knowledge of effective methods for mass distribution of medication and supplies to the public. We measured the time required for the key components of 2 drive-through vaccination clinics and summarized the results as they applied to providing medical countermeasures to large populations of children and adults. We hypothesized that vaccinating children in addition to adults would affect throughput time. Using 2 separate drive-through vaccination clinics, we measured elapsed time for vehicle flow and vaccination procedures. We calculated the median length of stay and the time to administer vaccinations based on the number of individual vaccinations given per vehicle, and compared the vehicles in which children (aged 9-18 years) were vaccinated to those in which only adults were vaccinated. A total of 2174 vaccinations and 1275 vehicles were timed during the 2 clinics. The number of vaccinations and vehicles per hour varied during the course of the day; the maximums were 200 and 361 per hour, respectively. The median throughput time was 5 minutes, and the median vaccination time was 48 seconds. Flow over time varied by the hour, and the optimum number of vaccinations per vehicle to maximize efficiency was between 3 and 4. Our findings showed that the presence of children raised the total number of vaccinations given per vehicle and, therefore, the total vaccination processing time per vehicle. However, the median individual procedure time in the vehicles with children was not significantly increased, indicating no need to calculate increased times for processing children 9 years of age or older during emergency planning. Drive-through clinics can provide a large number of seasonal influenza vaccinations in a relatively efficient manner; provide needed experience for students and practitioners in techniques for mass administration of medical countermeasures; and assist public health and emergency management personnel with disaster planning. Including children older than 9 years does not reduce efficiency. (Disaster Med Public Health Preparedness. 2013;0:1-7).

  14. Minimizing target interference in PK immunoassays: new approaches for low-pH-sample treatment.

    PubMed

    Partridge, Michael A; Pham, John; Dziadiv, Olena; Luong, Onson; Rafique, Ashique; Sumner, Giane; Torri, Albert

    2013-08-01

    Quantitating total levels of monoclonal antibody (mAb) biotherapeutics in serum using ELISA may be hindered by soluble targets. We developed two low-pH-sample-pretreatment techniques to minimize target interference. The first procedure involves sample pretreatment at pH <3.0 before neutralization and analysis in a target capture ELISA. Careful monitoring of acidification time is required to minimize potential impact on mAb detection. The second approach involves sample dilution into mild acid (pH ∼4.5) before transferring to an anti-human capture-antibody-coated plate without neutralization. Analysis of target-drug and drug-capture antibody interactions at pH 4.5 indicated that the capture antibody binds to the drug, while the drug and the target were dissociated. Using these procedures, total biotherapeutic levels were accurately measured when soluble target was >30-fold molar excess. These techniques provide alternatives for quantitating mAb biotherapeutics in the presence of a target when standard acid-dissociation procedures are ineffective.

  15. Understanding Preprocedure Patient Flow in IR.

    PubMed

    Zafar, Abdul Mueed; Suri, Rajeev; Nguyen, Tran Khanh; Petrash, Carson Cope; Fazal, Zanira

    2016-08-01

    To quantify preprocedural patient flow in interventional radiology (IR) and to identify potential contributors to preprocedural delays. An administrative dataset was used to compute time intervals required for various preprocedural patient-flow processes. These time intervals were compared across on-time/delayed cases and inpatient/outpatient cases by Mann-Whitney U test. Spearman ρ was used to assess any correlation of the rank of a procedure on a given day and the procedure duration to the preprocedure time. A linear-regression model of preprocedure time was used to further explore potential contributing factors. Any identified reason(s) for delay were collated. P < .05 was considered statistically significant. Of the total 1,091 cases, 65.8% (n = 718) were delayed. Significantly more outpatient cases started late compared with inpatient cases (81.4% vs 45.0%; P < .001, χ(2) test). The multivariate linear regression model showed outpatient status, length of delay in arrival, and longer procedure times to be significantly associated with longer preprocedure times. Late arrival of patients (65.9%), unavailability of physicians (18.4%), and unavailability of procedure room (13.0%) were the three most frequently identified reasons for delay. The delay was multifactorial in 29.6% of cases (n = 213). Objective measurement of preprocedural IR patient flow demonstrated considerable waste and highlighted high-yield areas of possible improvement. A data-driven approach may aid efficient delivery of IR care. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  16. The learning curve associated with the introduction of the subcutaneous implantable defibrillator.

    PubMed

    Knops, Reinoud E; Brouwer, Tom F; Barr, Craig S; Theuns, Dominic A; Boersma, Lucas; Weiss, Raul; Neuzil, Petr; Scholten, Marcoen; Lambiase, Pier D; Leon, Angel R; Hood, Margaret; Jones, Paul W; Wold, Nicholas; Grace, Andrew A; Olde Nordkamp, Louise R A; Burke, Martin C

    2016-07-01

    The subcutaneous implantable cardioverter defibrillator (S-ICD) was introduced to overcome complications related to transvenous leads. Adoption of the S-ICD requires implanters to learn a new implantation technique. The aim of this study was to assess the learning curve for S-ICD implanters with respect to implant-related complications, procedure time, and inappropriate shocks (IASs). In a pooled cohort from two clinical S-ICD databases, the IDE Trial and the EFFORTLESS Registry, complications, IASs at 180 days follow-up and implant procedure duration were assessed. Patients were grouped in quartiles based on experience of the implanter and Kaplan-Meier estimates of complication and IAS rates were calculated. A total of 882 patients implanted in 61 centres by 107 implanters with a median of 4 implants (IQR 1,8) were analysed. There were a total of 59 patients with complications and 48 patients with IAS. The complication rate decreased significantly from 9.8% in Quartile 1 (least experience) to 5.4% in Quartile 4 (most experience) (P = 0.02) and non-significantly for IAS from 7.9 to 4.8% (P = 0.10). Multivariable analysis demonstrated a hazard ratio of 0.78 (P = 0.045) for complications and 1.01 (P = 0.958) for IAS. Dual-zone programming increased with experience of the individual implanter (P < 0.001), which reduced IAS significantly in the multivariable model (HR 0.44, P = 0.01). Procedure time decreased from 75 to 65 min (P < 0.001). The complication rate and procedure time stabilized after Quartile 2 (>13 implants). There is a short and significant learning curve associated with physicians adopting the S-ICD. Performance stabilizes after 13 implants. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.

  17. Single-stage transanal endorectal pull-through for Hirschsprung's disease: perspective from a developing country.

    PubMed

    Pratap, Akshay; Shakya, Vikal Chandra; Biswas, Binay Kumar; Sinha, Arvind; Tiwari, Awadhesh; Agrawal, Chandra Shekhar; Adhikary, Shailesh

    2007-03-01

    The aim of this study was to evaluate the feasibility, results, and cost-effectiveness of totally transanal endorectal pull-through (TEPT) in the management of rectosigmoid and midsigmoid Hirschsprung's disease (HD) in a low-income country. Between March 2004 and December 2005, 19 children underwent totally TEPT procedure. The patients' ages ranged from 6 days to 13 years. The primary diagnosis in all 19 patients was HD confined to the rectosigmoid region in 15 and midsigmoid in 4. None had a preoperative colostomy. Follow-up period ranged from 4 to 20 months (mean, 8 months). Ages ranged from 0.25 to 65 months, with a mean of 16.24 months. Weights ranged from 3.4 to 13 kg, with a mean of 6.5 kg. Mean time from diagnosis to pull-through procedure was 26 days (range, 6-39 days). The mean length of rectosigmoid resection was 30 cm (range, 20-50 cm). The mean operative time was 95 minutes (range, 75-140 minutes). Mean intraoperative blood loss was 25 mL (range, 15-40 mL). There was one death unrelated to the procedure. One patient had enterocolitis 3 months postoperatively. Average frequency of defecation was 3 (range, 1-6) stools per day. TEPT was associated with a shorter operating time, less blood loss, early return to feeds, and an overall reduced cost. The safety and cost-effective benefits of transanal endorectal pull-through in the treatment of HD are of special interest for a developing country. Our data also suggest that functional outcome following TEPT is highly satisfactory and comparable with other established procedures.

  18. ABORT GAP CLEANING IN RHIC.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DREES,A.; AHRENS,L.; III FLILLER,R.

    2002-06-03

    During the RHIC Au-run in 2001 the 200 MHz storage cavity system was used for the first time. The rebucketing procedure caused significant beam debunching in addition to amplifying debunching due to other mechanisms. At the end of a four hour store, debunched beam could account for approximately 30%-40% of the total beam intensity. Some of it will be in the abort gap. In order to minimize the risk of magnet quenching due to uncontrolled beam losses at the time of a beam dump, a combination of a fast transverse kicker and copper collimators were used to clean the abortmore » gap. This report gives an overview of the gap cleaning procedure and the achieved performance.« less

  19. Temperature Histories in Ceramic-Insulated Heat-Sink Nozzle

    NASA Technical Reports Server (NTRS)

    Ciepluch, Carl C.

    1960-01-01

    Temperature histories were calculated for a composite nozzle wall by a simplified numerical integration calculation procedure. These calculations indicated that there is a unique ratio of insulation and metal heat-sink thickness that will minimize total wall thickness for a given operating condition and required running time. The optimum insulation and metal thickness will vary throughout the nozzle as a result of the variation in heat-transfer rate. The use of low chamber pressure results in a significant increase in the maximum running time of a given weight nozzle. Experimentally measured wall temperatures were lower than those calculated. This was due in part to the assumption of one-dimensional or slab heat flow in the calculation procedure.

  20. 40 CFR 86.608-98 - Test procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... testing diesel vehicles, or methanol-fueled Otto-cycle vehicles, the manufacturer shall allow a minimum of... determination. Warning: If at any time the concentration of hydrocarbons, of methanol, or of methanol and....156-98. To obtain a per-minute background emission rate, divide the total hydrocarbon mass calculated...

  1. Laparoscopic Total Extraperitoneal Hernia Repair Outcomes

    PubMed Central

    Bresnahan, Erin R.

    2016-01-01

    Background and Objectives: Laparoscopic inguinal hernia repair has become increasingly popular as an alternative to open surgery. The purpose of this study was to evaluate the safety and effectiveness of the laparoscopic total extraperitoneal procedure with the use of staple fixation and polypropylene mesh. Methods: A retrospective chart review examined outcomes of 1240 laparoscopic hernia operations in 783 patients, focusing on intraoperative and early postoperative complications, pain, and time until return to work and normal physical activities. Results: There were no intraoperative complications in this series; 106 patients experienced early postoperative complications across 8 evaluated categories: urinary retention (4.1%), seroma (3.0%), testicular/hemiscrotal swelling (1.9%), testicular atrophy (0%), hydrocele (0.6%), mesh infection (0.1%), and neurological symptoms (transient, 1.0%; persistent, 0.2%). Patients used an average of 5.6 Percocet pills after the procedure, and mean times until return to work and normal activities, including their routine exercise regimen, were 3.0 and 3.8 days, respectively. Conclusion: Complication rates and convalescence times were considered equivalent or superior to those found in other studies assessing both laparoscopic and open techniques. The usage of multiple Endostaples did not result in increased neurologic complications in the early postoperative period when compared with findings in the literature. In the hands of an experienced surgeon, total extraperitoneal repair is a safe, effective alternative to open inguinal hernia repair. PMID:27493471

  2. Comparisons between conventional, ultrasound-assisted and microwave-assisted methods for extraction of anthraquinones from Heterophyllaea pustulata Hook f. (Rubiaceae).

    PubMed

    Barrera Vázquez, M F; Comini, L R; Martini, R E; Núñez Montoya, S C; Bottini, S; Cabrera, J L

    2014-03-01

    This work reports a comparative study about extraction methods used to obtain anthraquinones (AQs) from stems and leaves of Heterophyllae pustulata Hook (Rubiáceae). One of the conventional procedures used to extract these metabolites from a vegetable matrix is by successive Soxhlet extractions with solvents of increasing polarity: starting with hexane to eliminate chlorophylls and fatty components, following by benzene and finally ethyl acetate. However, this technique shows a low extraction yield of total AQs, and consumes large quantities of solvent and time. Ultrasound-assisted extraction (UAE) and microwave-assisted extraction (MAE) have been investigated as alternative methods to extract these compounds, using the same sequence of solvents. It was found that UAE increases the extraction yield of total AQs and reduces the time and amount of solvent used. Nevertheless, the combination UAE with benzene, plus MAE with ethyl acetate at a constant power of 900 W showed the best results. A higher yield of total AQs was obtained in less time and using the same amount of solvent that UAE. The optimal conditions for this latter procedure were UAE with benzene at 50 °C during 60 min, followed by MAE at 900 W during 15 min using ethyl acetate as extraction solvent. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Patient controlled sedation using a standard protocol for dressing changes in burns: patients' preference, procedural details and a preliminary safety evaluation.

    PubMed

    Nilsson, Andreas; Steinvall, Ingrid; Bak, Zoltan; Sjöberg, Folke

    2008-11-01

    Patient controlled sedation (PCS) enables patients to titrate doses of drugs by themselves during different procedures involving pain or discomfort. We studied it in a prospective crossover design using a fixed protocol without lockout time to examine it as an alternative method of sedation for changing dressings in burned patients. Eleven patients with >10% total burn surface area (TBSA) had their dressings changed, starting with sedation by an anaesthetist (ACS). The second dressing change was done with PCS (propofol/alfentanil) and the third time the patients had to choose ACS or PCS. During the procedures, data on cardiopulmonary variables, sedation (bispectral index), pain intensity (VAS), procedural details, doses of drugs, and patients' preferences were collected to compare the two sedation techniques. The study data indicated that wound care in burned patients is feasible with a standardized PCS protocol. The patients preferred PCS to ACS on the basis of self-control, and because they had less discomfort during the recovery period. Wound care was also considered adequate by the staff during PCS. No respiratory (respiratory rate/transcutaneous PCO(2)) or cardiovascular (heart rate/blood pressure) adverse events were recorded at any time during any of the PCS procedures. The doses of propofol and alfentanil and BIS index decrease were less during PCS than ACS. Procedural pain was higher during PCS but lower after the procedure. We suggest that PCS using a standard protocol is an interesting alternative to anaesthetist-provided sedation during dressing changes. It seems effective, saves resources, is safe, and at same time is preferred by the patients. The strength of these conclusions is, however, hampered by the small size of this investigation and therefore further studies are warranted.

  4. Reduced-dose C-arm computed tomography applications at a pediatric institution.

    PubMed

    Acord, Michael; Shellikeri, Sphoorti; Vatsky, Seth; Srinivasan, Abhay; Krishnamurthy, Ganesh; Keller, Marc S; Cahill, Anne Marie

    2017-12-01

    Reduced-dose C-arm computed tomography (CT) uses flat-panel detectors to acquire real-time 3-D images in the interventional radiology suite to assist with anatomical localization and procedure planning. To describe dose-reduction techniques for C-arm CT at a pediatric institution and to provide guidance for implementation. We conducted a 5-year retrospective study on procedures using an institution-specific reduced-dose protocol: 5 or 8 s Dyna Rotation, 248/396 projection images/acquisition and 0.1-0.17 μGy/projection dose at the detector with 0.3/0.6/0.9-mm copper (Cu) filtration. We categorized cases by procedure type and average patient age and calculated C-arm CT and total dose area product (DAP). Two hundred twenty-two C-arm CT-guided procedures were performed with a dose-reduction protocol. The most common procedures were temporomandibular and sacroiliac joint injections (48.6%) and sclerotherapy (34.2%). C-arm CT was utilized in cases of difficult percutaneous access in less common applications such as cecostomy and gastrostomy placement, foreign body retrieval and thoracentesis. C-arm CT accounted for between 9.9% and 80.7% of the total procedural DAP. Dose-reducing techniques can preserve image quality for intervention while reducing radiation exposure to the child. This technology has multiple applications within pediatric interventional radiology and can be considered as an adjunctive imaging tool in a variety of procedures, particularly when percutaneous access is challenging despite routine fluoroscopic or ultrasound guidance.

  5. Augmented Endoscopic Images Overlaying Shape Changes in Bone Cutting Procedures.

    PubMed

    Nakao, Megumi; Endo, Shota; Nakao, Shinichi; Yoshida, Munehito; Matsuda, Tetsuya

    2016-01-01

    In microendoscopic discectomy for spinal disorders, bone cutting procedures are performed in tight spaces while observing a small portion of the target structures. Although optical tracking systems are able to measure the tip of the surgical tool during surgery, the poor shape information available during surgery makes accurate cutting difficult, even if preoperative computed tomography and magnetic resonance images are used for reference. Shape estimation and visualization of the target structures are essential for accurate cutting. However, time-varying shape changes during cutting procedures are still challenging issues for intraoperative navigation. This paper introduces a concept of endoscopic image augmentation that overlays shape changes to support bone cutting procedures. This framework handles the history of the location of the measured drill tip as a volume label and visualizes the remains to be cut overlaid on the endoscopic image in real time. A cutting experiment was performed with volunteers, and the feasibility of this concept was examined using a clinical navigation system. The efficacy of the cutting aid was evaluated with respect to the shape similarity, total moved distance of a cutting tool, and required cutting time. The results of the experiments showed that cutting performance was significantly improved by the proposed framework.

  6. Procedural learning is impaired in dyslexia: Evidence from a meta-analysis of serial reaction time studies☆

    PubMed Central

    Lum, Jarrad A.G.; Ullman, Michael T.; Conti-Ramsden, Gina

    2013-01-01

    A number of studies have investigated procedural learning in dyslexia using serial reaction time (SRT) tasks. Overall, the results have been mixed, with evidence of both impaired and intact learning reported. We undertook a systematic search of studies that examined procedural learning using SRT tasks, and synthesized the data using meta-analysis. A total of 14 studies were identified, representing data from 314 individuals with dyslexia and 317 typically developing control participants. The results indicate that, on average, individuals with dyslexia have worse procedural learning abilities than controls, as indexed by sequence learning on the SRT task. The average weighted standardized mean difference (the effect size) was found to be 0.449 (CI95: .204, .693), and was significant (p < .001). However, moderate levels of heterogeneity were found between study-level effect sizes. Meta-regression analyses indicated that studies with older participants that used SRT tasks with second order conditional sequences, or with older participants that used sequences that were presented a large number of times, were associated with smaller effect sizes. These associations are discussed with respect to compensatory and delayed memory systems in dyslexia. PMID:23920029

  7. RhBMP-7 for the treatment of nonunion of fractures of long bones.

    PubMed

    Papanagiotou, M; Dailiana, Z H; Karachalios, T; Varitimidis, S; Vlychou, M; Hantes, M; Malizos, K N

    2015-07-01

    We report the outcome of 84 nonunions involving long bones which were treated with rhBMP-7, in 84 patients (60 men: 24 women) with a mean age 46 years (18 to 81) between 2003 and 2011. The patients had undergone a mean of three previous operations (one to 11) for nonunion which had been present for a mean of 17 months (4 months to 20 years). The nonunions involved the lower limb in 71 patients and the remainder involved the upper limb. A total of 30 nonunions were septic. Treatment was considered successful when the nonunion healed without additional procedures. The relationship between successful union and the time to union was investigated and various factors including age and gender, the nature of the nonunion (location, size, type, chronicity, previous procedures, infection, the condition of the soft tissues) and type of index procedure (revision of fixation, type of graft, amount of rhBMP-7) were analysed. The improvement of the patients' quality of life was estimated using the Short Form (SF) 12 score. A total of 68 nonunions (80.9%) healed with no need for further procedures at a mean of 5.4 months (3 to 10) post-operatively. Multivariate logistic regression analysis of the factors affecting union suggested that only infection significantly affected the rate of union (p = 0.004).Time to union was only affected by the number of previous failed procedures (p = 0.006). An improvement of 79% and 32.2% in SF-12 physical and mental score, respectively, was noted within the first post-operative year. Rh-BMP-7 combined with bone grafts, enabled healing of the nonunion and improved quality of life in about 80% of patients. Aseptic nonunions were much more likely to unite than septic ones. The number of previous failed operations significantly delayed the time to union. ©2015 The British Editorial Society of Bone & Joint Surgery.

  8. Carbon dioxide insufflation during colonoscopy in deeply sedated patients

    PubMed Central

    Singh, Rajvinder; Neo, Eu Nice; Nordeen, Nazree; Shanmuganathan, Ganesananthan; Ashby, Angelie; Drummond, Sharon; Nind, Garry; Murphy, Elizabeth; Luck, Andrew; Tucker, Graeme; Tam, William

    2012-01-01

    AIM: To compare the impact of carbon dioxide (CO2) and air insufflation on patient tolerance/safety in deeply sedated patients undergoing colonoscopy. METHODS: Patients referred for colonoscopy were randomized to receive either CO2 or air insufflation during the procedure. Both the colonoscopist and patient were blinded to the type of gas used. During the procedure, insertion and withdrawal times, caecal intubation rates, total sedation given and capnography readings were recorded. The level of sedation and magnitude of patient discomfort during the procedure was assessed by a nurse using a visual analogue scale (VAS) (0-3). Patients then graded their level of discomfort and abdominal bloating using a similar VAS. Complications during and after the procedure were recorded. RESULTS: A total of 142 patients were randomized with 72 in the air arm and 70 in the CO2 arm. Mean age between the two study groups were similar. Insertion time to the caecum was quicker in the CO2 group at 7.3 min vs 9.9 min with air (P = 0.0083). The average withdrawal times were not significantly different between the two groups. Caecal intubation rates were 94.4% and 100% in the air and CO2 groups respectively (P = 0.012). The level of discomfort assessed by the nurse was 0.69 (air) and 0.39 (CO2) (P = 0.0155) and by the patient 0.82 (air) and 0.46 (CO2) (P = 0.0228). The level of abdominal bloating was 0.97 (air) and 0.36 (CO2) (P = 0.001). Capnography readings trended to be higher in the CO2 group at the commencement, caecal intubation, and conclusion of the procedure, even though this was not significantly different when compared to readings obtained during air insufflation. There were no complications in both arms. CONCLUSION: CO2 insufflation during colonoscopy is more efficacious than air, allowing quicker and better cecal intubation rates. Abdominal discomfort and bloating were significantly less with CO2 insufflation. PMID:22783048

  9. Carbon dioxide insufflation during colonoscopy in deeply sedated patients.

    PubMed

    Singh, Rajvinder; Neo, Eu Nice; Nordeen, Nazree; Shanmuganathan, Ganesananthan; Ashby, Angelie; Drummond, Sharon; Nind, Garry; Murphy, Elizabeth; Luck, Andrew; Tucker, Graeme; Tam, William

    2012-07-07

    To compare the impact of carbon dioxide (CO₂) and air insufflation on patient tolerance/safety in deeply sedated patients undergoing colonoscopy. Patients referred for colonoscopy were randomized to receive either CO₂ or air insufflation during the procedure. Both the colonoscopist and patient were blinded to the type of gas used. During the procedure, insertion and withdrawal times, caecal intubation rates, total sedation given and capnography readings were recorded. The level of sedation and magnitude of patient discomfort during the procedure was assessed by a nurse using a visual analogue scale (VAS) (0-3). Patients then graded their level of discomfort and abdominal bloating using a similar VAS. Complications during and after the procedure were recorded. A total of 142 patients were randomized with 72 in the air arm and 70 in the CO₂ arm. Mean age between the two study groups were similar. Insertion time to the caecum was quicker in the CO₂ group at 7.3 min vs 9.9 min with air (P = 0.0083). The average withdrawal times were not significantly different between the two groups. Caecal intubation rates were 94.4% and 100% in the air and CO₂ groups respectively (P = 0.012). The level of discomfort assessed by the nurse was 0.69 (air) and 0.39 (CO₂) (P = 0.0155) and by the patient 0.82 (air) and 0.46 (CO₂) (P = 0.0228). The level of abdominal bloating was 0.97 (air) and 0.36 (CO₂) (P = 0.001). Capnography readings trended to be higher in the CO₂ group at the commencement, caecal intubation, and conclusion of the procedure, even though this was not significantly different when compared to readings obtained during air insufflation. There were no complications in both arms. CO₂ insufflation during colonoscopy is more efficacious than air, allowing quicker and better cecal intubation rates. Abdominal discomfort and bloating were significantly less with CO₂ insufflation.

  10. The impact of operative time on complications after plastic surgery: a multivariate regression analysis of 1753 cases.

    PubMed

    Hardy, Krista L; Davis, Kathryn E; Constantine, Ryan S; Chen, Mo; Hein, Rachel; Jewell, James L; Dirisala, Karunakar; Lysikowski, Jerzy; Reed, Gary; Kenkel, Jeffrey M

    2014-05-01

    Little evidence within plastic surgery literature supports the precept that longer operative times lead to greater morbidity. The authors investigate surgery duration as a determinant of morbidity, with the goal of defining a clinically relevant time for increased risk. A retrospective chart review was conducted of patients who underwent a broad range of complex plastic surgical procedures (n = 1801 procedures) at UT Southwestern Medical Center in Dallas, Texas, from January 1, 2008 to January 31, 2012. Adjusting for possible confounders, multivariate logistic regression assessed surgery duration as an independent predictor of morbidity. To define a cutoff for increased risk, incidence of complications was compared among quintiles of surgery duration. Stratification by type of surgery controlled for procedural complexity. A total of 1753 cases were included in multivariate analyses with an overall complication rate of 27.8%. Most operations were combined (75.8%), averaging 4.9 concurrent procedures. Each hour increase in surgery duration was associated with a 21% rise in odds of morbidity (P < .0001). Compared with the first quintile of operative time (<2.0 hours), there was no change in complications until after 3.1 hours of surgery (odds ratio, 1.6; P = .017), with progressively greater odds increases of 3.1 times after 4.5 hours (P < .0001) and 4.7 times after 6.8 hours (P < .0001). When stratified by type of surgery, longer operations continued to be associated with greater morbidity. Surgery duration is an independent predictor of complications, with a significantly increased risk above 3 hours. Although procedural complexity undoubtedly affects morbidity, operative time should factor into surgical decision making.

  11. [Study on the peritoneal dissemination of endometrial cells during hysteroscopy].

    PubMed

    Duan, Hua; Li, Wei; Zhang, Ying; Zhao, Xia; Xia, En-Lan

    2007-02-01

    To study prospectively the likelihood and the affecting factors of endometrial cell dissemination into the peritoneal cavity during hysteroscopic procedures. A total of 121 patients with benign endometrial pathology underwent hysteroscopy combined with laparoscopy. All the patients had pelvic washings performed just before and after the procedure of hysteroscopy. We collected the peritoneal washings and analyzed the peritoneal cytology changes in both groups pre- and post-hysteroscopy, as well as the dissemination rate related to the time of hysteroscopy, the intrauterine distention pressure, the volume of distention media, and the feature of endometrial conditions. The ratio of positive endometrial cells in the peritoneal washings of post-hysteroscopy group was 51.2% (62/121), which was significantly higher than pre-hysteroscopy group, 38.0% (46/121) (P < 0.01). The mean operation time in the group of positive peritoneal cytology was (38 +/- 16) min, longer than the negative group (P < 0.05). However, there was no significant difference between the two groups with regard to the total volume of distention media, the distention pressure, and the endometrial feature (P > 0.05). Hysteroscopic procedures may have a risk of disseminating the endometrial cells into peritoneal cavity. Under a certain uterine distention pressure, the rate of dissemination is correlated with hysteroscopic duration.

  12. Time management in radiation oncology: evaluation of time, attendance of medical staff, and resources during radiotherapy for prostate cancer: the DEGRO-QUIRO trial.

    PubMed

    Keilholz, L; Willner, J; Thiel, H-J; Zamboglou, N; Sack, H; Popp, W

    2014-01-01

    In order to evaluate resource requirements, the German Society of Radiation Oncology (DEGRO) recorded the times needed for core procedures in the radio-oncological treatment of various cancer types within the scope of its QUIRO trial. The present study investigated the personnel and infrastructural resources required in radiotherapy of prostate cancer. The investigation was carried out in the setting of definitive radiotherapy of prostate cancer patients between July and October 2008 at two radiotherapy centers, both with well-trained staff and modern technical facilities at their disposal. Personnel attendance times and room occupancy times required for core procedures (modules) were each measured prospectively by two independently trained observers using time measurements differentiated on the basis of professional group (physician, physicist, and technician), 3D conformal (3D-cRT), and intensity-modulated radiotherapy (IMRT). Total time requirements of 983 min for 3D-cRT and 1485 min for step-and-shoot IMRT were measured for the technician (in terms of professional group) in all modules recorded and over the entire course of radiotherapy for prostate cancer (72-76 Gy). Times needed for the medical specialist/physician were 255 min (3D-cRT) and 271 min (IMRT), times of the physicist were 181 min (3D-cRT) and 213 min (IMRT). The difference in time was significant, although variations in time spans occurred primarily as a result of various problems during patient treatment. This investigation has permitted, for the first time, a realistic estimation of average personnel and infrastructural requirements for core procedures in quality-assured definitive radiotherapy of prostate cancer. The increased time needed for IMRT applies to the step-and-shoot procedure with verification measurements for each irradiation planning.

  13. Curriculum time compared to clinical procedures in amalgam and composite posterior restorations in U.S. dental schools: a preliminary study.

    PubMed

    Rey, Rosalia; Nimmo, Susan; Childs, Gail S; Behar-Horenstein, Linda S

    2015-03-01

    Dental clinicians have an expanding range of biomaterial choices for restoring tooth structure. Scientific developments in cariology, advances in dental biomaterials, and patients' esthetic concerns have led to a reduction in amalgam restorations and an increase in composite restorations. The aim of this study was to compare teaching time with students' clinical procedures in amalgam and composite posterior restorations in dental schools across the United States. Academic deans in 60 schools were invited to complete a survey that asked for the amount of instructional time for amalgam and composite posterior restorations and the number of clinical restorations performed by their Classes of 2009, 2010, and 2011. Of these 60, 12 returned surveys with complete data, for a 20% response rate. Responses from these schools showed little change in lecture and preclinical laboratory instruction from 2009 to 2011. There was a slight increase in two-surface restorations for both amalgam and composites; however, the total number of reported composite and amalgam restorations remained the same. Of 204,864 restorations reported, 53% were composite, and 47% were amalgam. There were twice as many multisurface large or complex amalgam restorations as composites. One-surface composite restorations exceeded amalgams. Among the participating schools, there was little to no change between curriculum time and clinical procedures. Findings from this preliminary study reflect a modest increase in two-surface resin-based restorations placed by dental students from 2009 to 2011 and little change in curricular time devoted to teaching amalgam restorations. The total number of posterior composite restorations placed by students in these schools was slightly higher than amalgams.

  14. Sensor-based electromagnetic navigation to facilitate implantation of left ventricular leads in cardiac resynchronization therapy.

    PubMed

    Döring, Michael; Sommer, Philipp; Rolf, Sascha; Lucas, Johannes; Breithardt, Ole A; Hindricks, Gerhard; Richter, Sergio

    2015-02-01

    Implantation of cardiac resynchronization therapy (CRT) devices can be challenging, time consuming, and fluoroscopy intense. To facilitate placement of left ventricular (LV) leads, a novel electromagnetic navigation system (MediGuide™, St. Jude Medical, St. Paul, MN, USA) has been developed, displaying real-time 3-D location of sensor-embedded delivery tools superimposed on prerecorded X-ray cine-loops of coronary sinus venograms. We report our experience and advanced progress in the use of this new electromagnetic tracking system to guide LV lead implantation. Between January 2012 and December 2013, 71 consecutive patients (69 ± 9 years, 76% male) were implanted with a CRT device using the new electromagnetic tracking system. Demographics, procedural data, and periprocedural adverse events were gathered. The impact of the operator's experience, optimized workflow, and improved software technology on procedural data were analyzed. LV lead implantation was successfully achieved in all patients without severe adverse events. Total procedure time measured 87 ± 37 minutes and the median total fluoroscopy time (skin-to-skin) was 4.9 (2.5-7.8) minutes with a median dose-area-product of 476 (260-1056) cGy*cm(2) . An additional comparison with conventional CRT device implantations showed a significant reduction in fluoroscopy time from 8.0 (5.8; 11.5) to 4.5 (2.8; 7.3) minutes (P = 0.016) and radiation dose from 603 (330; 969) to 338 (176; 680) cGy*cm(2) , respectively (P = 0.044 ). Use of the new navigation system enables safe and successful LV lead placement with improved orientation and significantly reduced radiation exposure during CRT implantation. © 2014 Wiley Periodicals, Inc.

  15. Total hydrocarbon content (THC) testing in liquid oxygen (LOX) systems

    NASA Astrophysics Data System (ADS)

    Meneghelli, B. J.; Obregon, R. E.; Ross, H. R.; Hebert, B. J.; Sass, J. P.; Dirschka, G. E.

    2015-12-01

    The measured Total Hydrocarbon Content (THC) levels in liquid oxygen (LOX) systems at Stennis Space Center (SSC) have shown wide variations. Examples of these variations include the following: 1) differences between vendor-supplied THC values and those obtained using standard SSC analysis procedures; and 2) increasing THC values over time at an active SSC test stand in both storage and run vessels. A detailed analysis of LOX sampling techniques, analytical instrumentation, and sampling procedures will be presented. Additional data obtained on LOX system operations and LOX delivery trailer THC values during the past 12-24 months will also be discussed. Field test results showing THC levels and the distribution of the THC's in the test stand run tank, modified for THC analysis via dip tubes, will be presented.

  16. Total Hydrocarbon Content (THC) Testing in Liquid Oxygen (LOX)

    NASA Technical Reports Server (NTRS)

    Meneghelli, B. J.; Obregon, R. E.; Ross, H. R.; Hebert, B. J.; Sass, J. P.; Dirschka, G. E.

    2016-01-01

    The measured Total Hydrocarbon Content (THC) levels in liquid oxygen (LOX) systems at Stennis Space Center (SSC) have shown wide variations. Examples of these variations include the following: 1) differences between vendor-supplied THC values and those obtained using standard SSC analysis procedures; and 2) increasing THC values over time at an active SSC test stand in both storage and run vessels. A detailed analysis of LOX sampling techniques, analytical instrumentation, and sampling procedures will be presented. Additional data obtained on LOX system operations and LOX delivery trailer THC values during the past 12-24 months will also be discussed. Field test results showing THC levels and the distribution of the THC's in the test stand run tank, modified for THC analysis via dip tubes, will be presented.

  17. Proficiency of virtual reality simulator training in flexible retrograde ureteroscopy renal stone management.

    PubMed

    Cai, Jian-liang; Zhang, Yi; Sun, Guo-feng; Li, Ning-chen; Yuan, Xue-li; Na, Yan-qun

    2013-10-01

    Minimally invasive flexible ureteroscopy techniques have widely adopted in the management of patients with renal stones. We performed this study to investigate the value of virtual reality simulator training in retrograde flexible ureteroscopy renal stone treatment for catechumen. Thirty catechumen, included 17 attending physicians and 13 associate chief physicians, were selected for study. The trainees first underwent 1-hour basic training to get familiar with the instrument and basic procedures, then followed by 4-hour practice on virtual reality simulators. Before and after the 4-hour training, all trainees undertake an assessment with task 7 program (right low pole calyces stone management). We documented for each trainee the total time of procedure, time of progressing from the orifice to stone, stone translocation and fragmentation time, laser operate proficiency scale, total laser energy, maximal size of residual stone fragments, number of trauma from the scopes and tools, damage to the scope and global rating scale (GRS). The proficiency of this training program was analyzed by the comparison of the first and second assessment outcomes. Significant improvement was observed in retrograde flexible ureteroscopy management of renal stone on virtual reality simulators after finishing the 4 hour special-purpose training. This was demonstrated by improvement in total procedure time ((18.37±2.59) minutes vs. (38.67±1.94) minutes), progressing time from the orifice to stone ((4.00±1.08) minutes vs. (13.80±2.01) minutes), time of stone translocation ((1.80±0.71) minutes vs. (6.57±1.01) minutes), fragmentation time ((4.43±1.25) minutes vs. (13.53±1.46) minutes), laser operate proficiency scale (8.47±0.73 vs. 3.77±0.77), total laser energy ((3231.6±401.4) W vs. (5329.8±448.9) W), maximal size of residual stone fragments ((2.66±0.39) mm vs. (5.77±0.63) mm), number of trauma from the scopes and tools (3.27±1.01 vs. 10.37±3.02), damage to the scope (0 vs. 0.97±0.76) and GRS (29.27±2.95 vs. 9.87±2.21). The differences between the first and the second assessment were all statistically significant (all P < 0.01). The virtual reality simulator training program can help the trainees to rapidly improve their retrograde flexible ureteroscopy skill in renal stone treatment.

  18. Impact of gastrectomy procedural complexity on surgical outcomes and hospital comparisons.

    PubMed

    Mohanty, Sanjay; Paruch, Jennifer; Bilimoria, Karl Y; Cohen, Mark; Strong, Vivian E; Weber, Sharon M

    2015-08-01

    Most risk adjustment approaches adjust for patient comorbidities and the primary procedure. However, procedures done at the same time as the index case may increase operative risk and merit inclusion in adjustment models for fair hospital comparisons. Our objectives were to evaluate the impact of surgical complexity on postoperative outcomes and hospital comparisons in gastric cancer surgery. Patients who underwent gastric resection for cancer were identified from a large clinical dataset. Procedure complexity was characterized using secondary procedure CPT codes and work relative value units (RVUs). Regression models were developed to evaluate the association between complexity variables and outcomes. The impact of complexity adjustment on model performance and hospital comparisons was examined. Among 3,467 patients who underwent gastrectomy for adenocarcinoma, 2,171 operations were distal and 1,296 total. A secondary procedure was reported for 33% of distal gastrectomies and 59% of total gastrectomies. Six of 10 secondary procedures were associated with adverse outcomes. For example, patients who underwent a synchronous bowel resection had a higher risk of mortality (odds ratio [OR], 2.14; 95% CI, 1.07-4.29) and reoperation (OR, 2.09; 95% CI, 1.26-3.47). Model performance was slightly better for nearly all outcomes with complexity adjustment (mortality c-statistics: standard model, 0.853; secondary procedure model, 0.858; RVU model, 0.855). Hospital ranking did not change substantially after complexity adjustment. Surgical complexity variables are associated with adverse outcomes in gastrectomy, but complexity adjustment does not affect hospital rankings appreciably. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. An improved procedure for the validation of satellite-based precipitation estimates

    NASA Astrophysics Data System (ADS)

    Tang, Ling; Tian, Yudong; Yan, Fang; Habib, Emad

    2015-09-01

    The objective of this study is to propose and test a new procedure to improve the validation of remote-sensing, high-resolution precipitation estimates. Our recent studies show that many conventional validation measures do not accurately capture the unique error characteristics in precipitation estimates to better inform both data producers and users. The proposed new validation procedure has two steps: 1) an error decomposition approach to separate the total retrieval error into three independent components: hit error, false precipitation and missed precipitation; and 2) the hit error is further analyzed based on a multiplicative error model. In the multiplicative error model, the error features are captured by three model parameters. In this way, the multiplicative error model separates systematic and random errors, leading to more accurate quantification of the uncertainties. The proposed procedure is used to quantitatively evaluate the recent two versions (Version 6 and 7) of TRMM's Multi-sensor Precipitation Analysis (TMPA) real-time and research product suite (3B42 and 3B42RT) for seven years (2005-2011) over the continental United States (CONUS). The gauge-based National Centers for Environmental Prediction (NCEP) Climate Prediction Center (CPC) near-real-time daily precipitation analysis is used as the reference. In addition, the radar-based NCEP Stage IV precipitation data are also model-fitted to verify the effectiveness of the multiplicative error model. The results show that winter total bias is dominated by the missed precipitation over the west coastal areas and the Rocky Mountains, and the false precipitation over large areas in Midwest. The summer total bias is largely coming from the hit bias in Central US. Meanwhile, the new version (V7) tends to produce more rainfall in the higher rain rates, which moderates the significant underestimation exhibited in the previous V6 products. Moreover, the error analysis from the multiplicative error model provides a clear and concise picture of the systematic and random errors, with both versions of 3B42RT have higher errors in varying degrees than their research (post-real-time) counterparts. The new V7 algorithm shows obvious improvements in reducing random errors in both winter and summer seasons, compared to its predecessors V6. Stage IV, as expected, surpasses the satellite-based datasets in all the metrics over CONUS. Based on the results, we recommend the new procedure be adopted for routine validation of satellite-based precipitation datasets, and we expect the procedure will work effectively for higher resolution data to be produced in the Global Precipitation Measurement (GPM) era.

  20. Hirschsprung's disease management: from multi staged operation to single staged transanal pull-through.

    PubMed

    Wang, J X; Dahal, G R

    2009-06-01

    Hirschsprung's disease (HD) is a common congenital disease of colorectum. Although it was described more than one century ago, the effective treatment was established only half a century later. The initially treatment consisted of preoperative diverting colostomy, followed by definite pull-through and closure of colostomy on later date. A variety of procedures like Swenson, Duhamel, Rehbein and Soave were evolved with time. With the better understanding of pathogenesis and improvement on surgical technique, now the operation has become less extensive. In recent days, the classical 3 staged procedure is replaced by single staged procedure. All the procedure can be completed transanally. Since De la Torre in 1998, first reported total transanal endorectal pull-through, it became the most popular technique for the treatment of HD.

  1. A randomized comparative study on modified Joel-Cohen incision versus Pfannenstiel incision for cesarean section

    PubMed Central

    Saha, Shyama Prasad; Bhattarcharjee, Nabendu; Das Mahanta, Sabysachi; Naskar, Animesh; Bhattacharyya, Sanjoy Kumar

    2013-01-01

    Objective: Pfanennstiel incision is the most commonly used incision for cesarean section, but may not be the best. This study compared the modified Joel-Cohen incision with the Pfannenstiel incision to evaluate whether techniques to open the abdomen might influence operative time, and maternal and neonatal outcomes. Material and Methods: In a randomized comparative trial, 302 women with gestational age >34 weeks, requiring cesarean section, were randomly assigned to either modified Joel-Cohen incision or Pfannenstiel incision for entry into the peritoneal cavity. The primary outcome measure was total time required for performing operation and secondary outcome measures were baby extraction time, number of haemostatic procedures used in the abdominal wall, postoperative morbidity, postoperative hospital stay and neonatal outcome. Results: Mean total operative time was significantly less in the modified Joel-Cohen group as compared to the Pfannenstiel group (29.81 vs 32.67 min, p<0.0001, 95%CI=2.253 to 3.467). Time taken to deliver the baby and haemostatic procedures required during operation were also significantly less in the modified Joel-Cohen group as compared to the Pfannenstiel group. Requirement of strong analgesics was higher in the Pfannenstiel group (53.64% vs 21.85%, p<0.0001). There was no statically significant difference in the incidence of postoperative wound complications but postoperative stay in hospital was significantly less in the modified Joel-Cohen group (p=0.002). Neonatal outcomes were similar in both groups. Conclusion: The modified Joel-Cohen incision for entry into peritoneal cavity during cesarean section is associated with reduced mean total operative and baby extraction times with less postoperative pain and shorter hospital stay, which may be beneficial and cost effective. PMID:24592067

  2. Robotic single-site pelvic lymphadenectomy.

    PubMed

    Tateo, Saverio; Nozza, Arrigo; Del Pezzo, Chiara; Mereu, Liliana

    2014-09-01

    To examine the feasibility of performing pelvic lymphadenectomy with robotic single site approach. Recent papers described the feasibility of robotic-single site hysterectomy [1-3] for benign and malign pathologies but only with the development of new single site 5mm instruments as the bipolar forceps, robotic single site platform can be safely utilized also for lymphadenectomy. A 65 year-old, multiparous patient with a body mass index of 22.5 and diagnosed with well differentiated adenocarcinoma of the endometrium underwent a robotic single-site peritoneal washing, total hysterectomy, bilateral adnexectomy and pelvic lymphadenectomy. The procedure was performed using the da Vinci Si Surgical System (Intuitive Surgical, Sunnyvale, CA) through a single 2,5 cm umbilical incision, with a multi-channel system and two single site robotic 5mm instruments. A 3-dimensional, HD 8.5mm endoscope and a 5mm accessory instrument were also utilized. Type I lymphonodes dissection for external iliac and obturator regions was performed [4]. Total operative time was 210 min; incision, trocar placement and docking time occurring in 12 min. Total console time was 183 min, estimated blood loss was 50 ml, no intra-operative or post-operative complications occurred. Hospital discharge occurred on post operative day 2 and total number of lymphnodes removed was 33. Difficulties in term of instrument's clashing and awkward motions have been encountered. Robotic single-site pelvic lymphadenectomy using bipolar forceps and monopolar hook is feasible. New developments are needed to improve surgical ergonomics and additional studies should be performed to explore possible benefits of this procedure. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Analysis of Radiation Effects in Digital Subtraction Angiography of Intracranial Artery Stenosis.

    PubMed

    Guo, Chaoqun; Shi, Xiaolei; Ding, Xianhui; Zhou, Zhiming

    2018-04-21

    Intracranial artery stenosis (IAS) is the most common cause for acute cerebral accidents. Digital subtraction angiography (DSA) is the gold standard to detect IAS and usually brings excess radiation exposure to examinees and examiners. The artery pathology might influence the interventional procedure, causing prolonged radiation effects. However, no studies on the association between IAS pathology and operational parameters are available. A retrospective analysis was conducted on 93 patients with first-ever stroke/transient ischemic attack, who received DSA examination within 3 months from onset in this single center. Comparison of baseline characteristics was determined by 2-tailed Student's t-test or the chi-square test between subjects with and without IAS. A binary logistic regression analysis was performed to determine the association between IAS pathology and the items with a P value <0.05 in Student's t-test or chi-square test. There were 93 candidates (42 with IAS and 51 without IAS) in this study. The 2 groups shared no significance of the baseline characteristics (P > 0.05). We found a significantly higher total time, higher kerma area product, greater total dose, and greater DSA dose in the IAS group than in those without IAS (P < 0.05). A binary logistic regression analysis indicated the significant association between total time and IAS pathology (P < 0.05) but no significance in kerma area product, radiation dose, and DSA dose (P > 0.05). IAS pathology would indicate a prolonged total time of DSA procedure in clinical practice. However, the radiation effects would not change with pathologic changes. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Premixed Digestion Salts for Kjeldahl Determination of Total Nitrogen in Selected Forest Soils

    Treesearch

    B. G. Blackmon

    1971-01-01

    Estimates of total soil nitrogen by a standard Kjeldahl procedure and a modified procedure employing packets of premixed digestion salts were closely correlated. (r2 = 0.983). The modified procedure appears to be as reliable all the standard method for determining total nitrogen in southern alluvial forest soils.

  5. Seismicity of the Bering Glacier Region: Inferences from Relocations Using Data from STEEP

    NASA Astrophysics Data System (ADS)

    Panessa, A. L.; Pavlis, G. L.; Hansen, R. A.; Ruppert, N.

    2008-12-01

    We relocated earthquakes recorded from 1990 to 2007 in the area of the Bering Glacier in southeastern Alaska to test a hypothesis that faults in this area are linked to glaciers. We used waveform correlation to improve arrival time measurements for data from all broadband channels including all the data from the STEEP experiment. We used a novel form of correlation based on interactive array processing of common receiver gathers linked to a three-dimensional grid of control points. This procedure produced 8556 gathers that we processed interactively to produce improved arrival time estimates. The interactive procedure allowed us to select which events in each gather were sufficiently similar to warrant correlation. Redundancy in the result was resolved in a secondary correlation that aligned event stacks of the same station-event pair associated with multiple control points. This procedure yielded only 2240 waveforms that correlated and modified only a total of 524 arrivals in a total database of 12263 arrivals. The correlation procedure changed arrival times on 145 of 509 events in this database. Events with arrivals constrained by correlation were not clustered but were randomly distributed throughout the study area. We used a version of the Progressive Multiple Event Location (PMEL) that analyzed data at each control point to invert for relative locations and a set of path anomalies for each control point. We applied the PMEL procedure with different velocity models and constraints and compared the results to a HypoDD solution produced from the original arrival time data. The relocations are all significant improvements from the standard single-event, catalog locations. The relocations suggest the seismicity in this region is mostly linked to fold and thrust deformation in the Yakatat block. There is a suggestion of a north-dipping trend to much of the seismicity, but the dominant trend is a fairly diffuse cloud of events largely confined to the Yakatat block south of the Bagley Icefield. This is consistent with the recently published tectonic model by Berger et al. (2008).

  6. A prospective case control comparison of the ZeroGravity system versus a standard lead apron as radiation protection strategy in neuroendovascular procedures.

    PubMed

    Haussen, Diogo C; Van Der Bom, Imramsjah Martijn John; Nogueira, Raul G

    2016-10-01

    We aimed to compare the performance of the ZeroGravity (ZG) system (radiation protection system composed by a suspended lead suit) against the use of standard protection (lead apron (LA), thyroid shield, lead eyeglasses, table skirts, and ceiling suspended shield) in neuroangiography procedures. Radiation exposure data were prospectively collected in consecutive neuroendovascular procedures between December 2014 and February 2015. Operator No 1 was assigned to the use of an LA (plus lead glasses, thyroid shield, and a 1 mm hanging shield at the groin) while operator No 2 utilized the ZG system. Dosimeters were used to measure peak skin dose for the head, thyroid, and left foot. The two operators performed a total of 122 procedures during the study period. The ZG operator was more commonly the primary operator compared with the LA operator (85% vs 71%; p=0.04). The mean anterior-posterior (AP), lateral, and cumulative dose area product (DAP) radiation exposure as well as the mean fluoroscopy time were not statistically different between the operators' cases. The peak skin dose to the head of the operator with LA was 2.1 times higher (3380 vs 1600 μSv), while the thyroid was 13.9 (4460 vs 320 μSv), the mediastinum infinitely (520 vs 0 μSv), and the foot 3.3 times higher (4870 vs 1470 μSv) compared with the ZG operator, leading to an overall accumulated dose 4 times higher. The ratio of cumulative operator received dose/total cumulative DAP was 2.5 higher on the LA operator. The ZG radiation protection system leads to substantially lower radiation exposure to the operator in neurointerventional procedures. However, substantial exposure may still occur at the level of the lens and thyroid to justify additional protection. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  7. Quality-assurance data for routine water analyses by the U.S. Geological Survey laboratory in Troy, New York - July 2003 through June 2005

    USGS Publications Warehouse

    Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.

    2009-01-01

    The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's Lab Master data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality control samples analyzed from July 2003 through June 2005. Results for the quality-control samples for 20 analytical procedures were evaluated for bias and precision. Control charts indicate that data for five of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, pH, silicon, and sodium. Seven of the analytical procedures were biased throughout the analysis period for the high-concentration sample, but were within control limits; these procedures were: dissolved organic carbon, chloride, nitrate (ion chromatograph), nitrite, silicon, sodium, and sulfate. The calcium and magnesium procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The total aluminum and specific conductance procedures were biased for the high-concentration and low-concentration samples, but were within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 17 of 18 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for dissolved organic carbon. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 18 of the 22 analytes. At least 85 percent of the samples met data-quality objectives for all analytes except total monomeric aluminum (82 percent of samples met objectives), total aluminum (77 percent of samples met objectives), chloride (80 percent of samples met objectives), fluoride (76 percent of samples met objectives), and nitrate (ion chromatograph) (79 percent of samples met objectives). The ammonium and total dissolved nitrogen did not meet the data-quality objectives. Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality over the time period, with ratings for each sample in the satisfactory, good, and excellent ranges or less than 10 percent error. The P-sample (low-ionic-strength constituents) analysis had one marginal and two unsatisfactory ratings for the chloride procedure. The T-sample (trace constituents)analysis had two unsatisfactory ratings and one high range percent error for the aluminum procedure. The N-sample (nutrient constituents) analysis had one marginal rating for the nitrate procedure. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 84 percent of the samples met data-quality objectives for 11 of the 14 analytes; the exceptions were ammonium, total aluminum, and acid-neutralizing capacity. The ammonium procedure did not meet data quality objectives in all studies. Data-quality objectives were not met in 23 percent of samples analyzed for total aluminum and 45 percent of samples analyzed acid-neutralizing capacity. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 86 percent of the samples analyzed for calcium, chloride, fluoride, magnesium, pH, potassium, sodium, and sulfate. Data-quality objectives were not met by samples analyzed for fluoride. 

  8. Efficacy of the RADPAD protective drape during real world complex percutaneous coronary intervention procedures.

    PubMed

    Murphy, John C; Darragh, Karen; Walsh, Simon J; Hanratty, Colm G

    2011-11-15

    The RADPAD is a lead-free surgical drape containing bismuth and barium that has been demonstrated to reduce scatter radiation exposure to primary operators during fluoroscopic procedures. It is not known to what degree the RADPAD reduces radiation exposure in operators who perform highly complex percutaneous coronary intervention (PCI) requiring prolonged fluoroscopic screening times. Sixty consecutive patients due to undergo elective complex PCI involving rotational atherectomy, multivessel PCI, or chronic total occlusions were randomized in a 1:1 pattern to have their procedures performed with and without the RADPAD drape in situ. Dosimetry was performed on the left arm of the primary operator. There were 40 cases of chronic total occlusion, including 28 with contralateral injections; 15 cases involving rotational atherectomy; and 5 cases of multivessel PCI. There was no significant difference in screening times or dose-area products between the 2 patient groups. Primary operator radiation dose relative to screening time (RADPAD: slope = 1.44, R² = 0.25; no RADPAD: slope = 4.60, R² = 0.26; analysis of covariance F = 4.81, p = 0.032) and dose-area product (RADPAD: slope = 0.003, R² = 0.26; no RADPAD: slope = 0.011, R² = 0.52; analysis of covariance F = 12.54, p = 0.008) was significantly smaller in the RADPAD cohort compared to the no-RADPAD group. In conclusion, the RADPAD significantly reduces radiation exposure to primary operators during prolonged, complex PCI cases. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. Student Endodontic Performance with and without Numerical Requirements.

    ERIC Educational Resources Information Center

    Lee, Charles Q.; And Others

    1994-01-01

    A study compared dental student performance in clinical endodontics under two instructional approaches, one in which number of procedures completed by students (n=79) was measured and one (n=84 students) emphasizing total patient care and stricter accounting of clinical treatment time. Results indicated the latter group treated fewer teeth but…

  10. Robotic-Assisted Procedures in Pediatric Surgery: A Critical Appraisal of the Current Best Evidence in Comparison to Conventional Minimally Invasive Surgery.

    PubMed

    Friedmacher, Florian; Till, Holger

    2015-11-01

    In recent years, the use of robotic-assisted surgery (RAS) has expanded within pediatric surgery. Although increasing numbers of pediatric RAS case-series have been published, the level of evidence remains unclear, with authors mainly focusing on the comparison with open surgery rather than the corresponding laparoscopic approach. The aim of this study was to critically appraise the published literature comparing pediatric RAS with conventional minimally invasive surgery (MIS) in order to evaluate the current best level of evidence. A systematic literature-based search for studies comparing pediatric RAS with corresponding MIS procedures was performed using multiple electronic databases and sources. The level of evidence was determined using the Oxford Centre for Evidence-based Medicine (OCEBM) criteria. A total of 20 studies met defined inclusion criteria, reporting on five different procedures: fundoplication (n=8), pyeloplasty (n=8), nephrectomy (n=2), gastric banding (n=1), and sleeve gastrectomy (n=1). Included publications comprised 5 systematic reviews and 15 cohort/case-control studies (OCEBM Level 3 and 4, respectively). No studies of OCEBM Level 1 or 2 were identified. Limited evidence indicated reduced operative time (pyeloplasty) and shorter hospital stay (fundoplication) for pediatric RAS, whereas disadvantages were longer operative time (fundoplication, nephrectomy, gastric banding, and sleeve gastrectomy) and higher total costs (fundoplication and sleeve gastrectomy). There were no differences reported for complications, success rates, or short-term outcomes between pediatric RAS and conventional MIS in these procedures. Inconsistency was found in study design and follow-up with large clinical heterogeneity. The best available evidence for pediatric RAS is currently OCEBM Level 3, relating only to fundoplication and pyeloplasty. Therefore, higher-quality studies and comparative data for other RAS procedures in pediatric surgery are required.

  11. Concentration and flux of total and dissolved phosphorus, total nitrogen, chloride, and total suspended solids for monitored tributaries of Lake Champlain, 1990-2012

    USGS Publications Warehouse

    Medalie, Laura

    2014-01-01

    Annual and daily concentrations and fluxes of total and dissolved phosphorus, total nitrogen, chloride, and total suspended solids were estimated for 18 monitored tributaries to Lake Champlain by using the Weighted Regressions on Time, Discharge, and Seasons regression model. Estimates were made for 21 or 23 years, depending on data availability, for the purpose of providing timely and accessible summary reports as stipulated in the 2010 update to the Lake Champlain “Opportunities for Action” management plan. Estimates of concentration and flux were provided for each tributary based on (1) observed daily discharges and (2) a flow-normalizing procedure, which removed the random fluctuations of climate-related variability. The flux bias statistic, an indicator of the ability of the Weighted Regressions on Time, Discharge, and Season regression models to provide accurate representations of flux, showed acceptable bias (less than ±10 percent) for 68 out of 72 models for total and dissolved phosphorus, total nitrogen, and chloride. Six out of 18 models for total suspended solids had moderate bias (between 10 and 30 percent), an expected result given the frequently nonlinear relation between total suspended solids and discharge. One model for total suspended solids with a very high bias was influenced by a single extreme value; however, removal of that value, although reducing the bias substantially, had little effect on annual fluxes.

  12. Anesthesia for the patient undergoing total knee replacement: current status and future prospects

    PubMed Central

    Turnbull, Zachary A; Sastow, Dahniel; Giambrone, Gregory P; Tedore, Tiffany

    2017-01-01

    Total knee arthroplasty (TKA) has become one of the most common orthopedic surgical procedures performed nationally. As the population and surgical techniques for TKAs have evolved over time, so have the anesthesia and analgesia used for these procedures. General anesthesia has been the dominant form of anesthesia utilized for TKA in the past, but regional anesthetic techniques are on the rise. Multiple studies have shown the potential for regional anesthesia to improve patient outcomes, such as a decrease in intraoperative blood loss, length of stay, and patient mortality. Anesthesiologists are also moving toward multimodal analgesia, which includes peripheral nerve blockade, periarticular injection, and preemptive analgesia. The goal of multimodal analgesia is to improve perioperative pain control while minimizing systemic narcotic consumption. With improved postoperative pain management and rapid patient rehabilitation, new clinical pathways have been engineered to fast track patient recovery after orthopedic procedures. The aim of these clinical pathways was to improve quality of care, minimize unnecessary variations in care, and reduce cost by using streamlined procedures and protocols. The future of TKA care will be formalized clinical pathways and tracks to better optimize perioperative algorithms with regard to pain control and perioperative rehabilitation. PMID:28331362

  13. Anesthesia for the patient undergoing total knee replacement: current status and future prospects.

    PubMed

    Turnbull, Zachary A; Sastow, Dahniel; Giambrone, Gregory P; Tedore, Tiffany

    2017-01-01

    Total knee arthroplasty (TKA) has become one of the most common orthopedic surgical procedures performed nationally. As the population and surgical techniques for TKAs have evolved over time, so have the anesthesia and analgesia used for these procedures. General anesthesia has been the dominant form of anesthesia utilized for TKA in the past, but regional anesthetic techniques are on the rise. Multiple studies have shown the potential for regional anesthesia to improve patient outcomes, such as a decrease in intraoperative blood loss, length of stay, and patient mortality. Anesthesiologists are also moving toward multimodal analgesia, which includes peripheral nerve blockade, periarticular injection, and preemptive analgesia. The goal of multimodal analgesia is to improve perioperative pain control while minimizing systemic narcotic consumption. With improved postoperative pain management and rapid patient rehabilitation, new clinical pathways have been engineered to fast track patient recovery after orthopedic procedures. The aim of these clinical pathways was to improve quality of care, minimize unnecessary variations in care, and reduce cost by using streamlined procedures and protocols. The future of TKA care will be formalized clinical pathways and tracks to better optimize perioperative algorithms with regard to pain control and perioperative rehabilitation.

  14. Improvement of a sample preparation procedure for multi-elemental determination in Brazil nuts by ICP-OES.

    PubMed

    Welna, Maja; Szymczycha-Madeja, Anna

    2014-04-01

    Various sample preparation procedures, such as common wet digestions and alternatives based on solubilisation in aqua regia or tetramethyl ammonium hydroxide, were compared for the determination of the total Ba, Ca, Cr, Cd, Cu, Fe, Mg, Mn, Ni, P, Pb, Se, Sr and Zn contents in Brazil nuts using inductively coupled plasma optical emission spectrometry (ICP-OES). For measurement of Se, a hydride generation technique was used. The performance of these procedures was measured in terms of precision, accuracy and limits of detection of the elements. It was found that solubilisation in aqua regia gave the best results, i.e. limits of detection from 0.60 to 41.9 ng ml(-1), precision of 1.0-3.9% and accuracy better than 5%. External calibration with simple standard solutions could be applied for the analysis. The proposed procedure is simple, reduces sample handling, and minimises the time and reagent consumption. Thus, this can be a vital alternative to traditional sample treatment approaches based on the total digestion with concentrated reagents. A phenomenon resulting from levels of Ba, Se and Sr in Brazil nuts was also discussed.

  15. Knowledge of chronic total occlusion among Polish interventional cardiologists.

    PubMed

    Bryniarski, Krzysztof L; Zabojszcz, Michał; Dębski, Grzegorz; Marchewka, Jakub; Legutko, Jacek; Surowiec, Sławomir; Siudak, Zbigniew; Żmudka, Krzysztof; Dudek, Dariusz; Bryniarski, Leszek

    2015-01-01

    Chronic total occlusion (CTO) recanalization is indicated in patients with symptoms and evidence of ischemia, but in most cases those types of lesions are still treated medically. In the last few years CTO angioplasty technique has changed dramatically due to considerable advances in techniques and dedicated equipment. An attempt to assess the state of knowledge of technical aspects of CTO angioplasty of coronary arteries among Polish interventional cardiologists. Questionnaire survey performed during two major Polish invasive cardiology workshops. In the study there participated 113 physicians with an average length of work experience of 13 years, most of them cardiologists certified as independent primary operators. The majority of respondents recognized the need of prevention of thrombotic complications through control of activated coagulation time during the CTO procedures. Prevention of renal complications and X-ray protection are also recognized as a significant part of the procedures. The benefits from the use of over-the-wire microcatheters and balloons, the proper choice of dedicated guidewires, contralateral injections and retrograde technique are underestimated. Despite satisfactory knowledge about indications and qualification for the CTO procedure, the awareness of procedural aspects (particularly the retrograde technique) as well as the dedicated CTO equipment among Polish interventional cardiologists is still insufficient.

  16. Effects of group response-cost procedures on cash shortages in a small business

    PubMed Central

    Marholin, David; Gray, Deanne

    1976-01-01

    The effect of a group response-cost procedure (accompanied by verbal and written instruction) designed to decrease cash shortages in a small business was evaluated with a reversal design. When cash shortages were subtracted from the six employees' salaries on days in which the shortage exceeded 1% of total daily sales, the magnitude of daily shortages sharply decreased. This response-cost contingency was used only three times throughout the study, with a maximum cost of $8.70 per subject over the 41-day period. The efficacy of the procedures may be due to either increased precision in change calculations, a decreased frequency of stealing from the cash register, increased shortchanging of customers, and/or increased incidents of register under-ringing. Ethical questions relative to the utilization of group punishment procedures are raised, and it was concluded that the procedures used were more humane than commonly used alternatives. PMID:16795515

  17. Fast 3-T MR-guided transrectal prostate biopsy using an in-room tablet device for needle guide alignment: a feasibility study.

    PubMed

    Overduin, Christiaan G; Heidkamp, Jan; Rothgang, Eva; Barentsz, Jelle O; de Lange, Frank; Fütterer, Jurgen J

    2018-05-22

    To assess the feasibility of adding a tablet device inside the scanner room to assist needle-guide alignment during magnetic resonance (MR)-guided transrectal prostate biopsy. Twenty patients with one cancer-suspicious region (CSR) with PI-RADS score ≥ 4 on diagnostic multiparametric MRI were prospectively enrolled. Two orthogonal scan planes of an MR fluoroscopy sequence (~3 images/s) were aligned to the CSR and needle-guide pivoting point. Targeting was achieved by manipulating the needle-guide under MR fluoroscopy feedback on the in-room tablet device. Technical feasibility and targeting success were assessed. Complications and biopsy procedure times were also recorded. Needle-guide alignment with the in-room tablet device was technically successful in all patients and allowed sampling after a single alignment step in 19/20 (95%) CSRs (median size 14 mm, range: 4-45). Biopsy cores contained cancer in 18/20 patients. There were no per-procedural or post-biopsy complications. Using the tablet device, the mean time to first biopsy was 5.8 ± 1.0 min and the mean total procedure time was 23.7 ± 4.1 min. Use of an in-room tablet device to assist needle-guide alignment was feasible and safe during MR-guided transrectal prostate biopsy. Initial experience indicates potential for procedure time reduction. • Performing MR-guided prostate biopsy using an in-room tablet device is feasible. • CSRs could be sampled after a single alignment step in 19/20 patients. • The mean procedure time for biopsy with the tablet device was 23.7 min.

  18. [Preparation procedures of anti-complementary polysaccharides from Houttuynia cordata].

    PubMed

    Zhang, Juanjuan; Lu, Yan; Chen, Daofeng

    2012-07-01

    To establish and optimize the preparation procedures of the anti-complementary polysaccharides from Houttuynia cordata. Based on the yield and anti-complementary activity in vitro, the conditions of extraction and alcohol precipitating process were optimized by orthogonal tests. The optimal condition of deproteinization was determined according to the results of protein removed and polysaccharide maintained. The best decoloring method was also optimized by orthogonal experimental design. The optimized preparation procedures were given as follows: extract the coarse powder 3 times with 50 times volume of water at 90 degrees C for 2 hours every time, combine the extracts and concentrate appropriately, equivalent to 0.12 g of H. cordata per milliliter. Add 4 times volume of 90% ethanol to the extract, allow to stand for 24 hours to precipitate totally, filter and the precipitate was successfully washed with anhydrous alcohol, acetone and anhydrous ether. Resolve the residue with water, add trichloroacetic acid (TCA) to a concentration of 20% to remove protein. Decoloration was at a concentration of 3% with activated carbon at pH 3.0, 50 degrees C for 50 min. The above procedures above were tested 3 times, resulting in the average yield of polysaccharides at 4.03% (RSD 0.96%), the average concentrations of polysaccharides and protein at 80.97% (RSD 1.5%) and 2.02% (RSD 2.3%), and average CH50 at 0.079 g x L-(-1) (RSD 3.6%). The established and optimized procedures are repeatable and reliable to prepare the anti-complementary polysaccharides with high quality and activity from H. cordata.

  19. Work Loads and Practice Patterns of General Surgeons in the United States, 1995–1997

    PubMed Central

    Ritchie, Wallace P.; Rhodes, Robert S.; Biester, Thomas W.

    1999-01-01

    Objective To characterize the work loads and practice patterns of general surgeons in the United States over a 3-year period (1995 to 1997). Methods The surgical operative logs of 2434 “generalist” general surgeons recertifying in surgery form the basis of this report. Selected demographics of the group are as follows: location: 50% Northeast and Southeast, 21% Midwest, 29% West and Southwest; practice type: 45% solo, 40% group, 9% academics; size of practice community: 46% highly urban, 19% rural. Parameters evaluated were the average number of procedures and their distribution by category related to geographic area, practice type, community size, and other parameters. Statistical analysis was accomplished using analysis of variance. Results No significant year-to-year differences were observed between cohorts. The average numbers of procedures per surgeon per year was 398, distributed as follows: abdomen 102, alimentary tract 63, breast 54, endoscopic 51, vascular 39, trauma 6, endocrine 4, and head and neck, 3. Eleven percent of the 398 procedures were performed laparoscopically. Major index cases were largely concentrated with small groups of surgeons representing 5% to 10% of the total. Significant differences were as follows: surgeons in the Northeast and West performed far fewer procedures than those elsewhere. Urban surgeons performed a few more tertiary-type procedures than did rural ones; however, rural surgeons performed many more total procedures, especially in endoscopy, laparoscopy, gynecology, genitourinary, and orthopedics. Academic surgeons performed substantially fewer total procedures as a group than did nonacademic ones and in all categories except liver, transplant, and pancreas. Male surgeons performed more procedures than did female surgeons, except those involving the breast. More procedures were done by surgeons in group practice than by those in solo practice. U.S. medical graduates and international medical graduates had similar work loads but with a different distribution. Conclusions This unique database will be useful in tracking trends over time. More importantly, it demonstrates that general surgery practice in the United States is extremely heterogeneous, a fact that must be acknowledged in any future workforce deliberations. PMID:10522723

  20. Pattern of periodontal treatments performed at the periodontology clinic of the Lagos University Teaching Hospital: 22 months review.

    PubMed

    Umeizudike, K A; Ayanbadejo, P O; Savage, K O; Taiwo, O A

    2012-01-01

    A critical evaluation of the pattern of periodontal procedures performed is important in providing useful data to the administrator for proper planning and budgeting for dental health service. To assess the pattern of periodontal treatments performed over a given period of time at the Periodontology clinic of the Lagos University Teaching Hospital, Lagos, Nigeria. This was a twenty two months retrospective study of all periodontal procedures performed on patients seen at the periodontology clinic of the Lagos University Teaching Hospital between January 2006 and October 2007. The periodontology treatment record was used to retrieve information which included the patient's age, gender, diagnosis and periodontal procedures given. The procedures were further categorized into surgical and nonsurgical groups. The information obtained was then analyzed using Epi Info 2007 statistical software. A total of 1,938 patients were seen during this period. Females were 1009 (52.1%) and males were 929 (47.9%). (F/M, 1.1:1). A total of 2,110 periodontal treatments were performed. Majority of the patients received non-surgical periodontal therapy which constituted the bulk (96.3%) of the therapies. Scaling and polishing was the most frequently performed non-surgical procedure accounting for 1261 (62.1%) with slightly more males receiving the treatment. Of the surgical treatment modalities, operculectomy accounted for 65.4% and was carried out on more females than males. Regenerative procedures were the least performed surgical treatments. This study highlighted that non-surgical periodontal therapy, particularly scaling and polishing was the most frequently utilized periodontal procedure. Operculectomy was the predominant surgical procedure performed. The low percentage of regenerative surgical procedures was however below the desired expectation.

  1. Shortened OR time and decreased patient risk through use of a modular surgical instrument with artificial intelligence.

    PubMed

    Miller, David J; Nelson, Carl A; Oleynikov, Dmitry

    2009-05-01

    With a limited number of access ports, minimally invasive surgery (MIS) often requires the complete removal of one tool and reinsertion of another. Modular or multifunctional tools can be used to avoid this step. In this study, soft computing techniques are used to optimally arrange a modular tool's functional tips, allowing surgeons to deliver treatment of improved quality in less time, decreasing overall cost. The investigators watched University Medical Center surgeons perform MIS procedures (e.g., cholecystectomy and Nissen fundoplication) and recorded the procedures to digital video. The video was then used to analyze the types of instruments used, the duration of each use, and the function of each instrument. These data were aggregated with fuzzy logic techniques using four membership functions to quantify the overall usefulness of each tool. This allowed subsequent optimization of the arrangement of functional tips within the modular tool to decrease overall time spent changing instruments during simulated surgical procedures based on the video recordings. Based on a prototype and a virtual model of a multifunction laparoscopic tool designed by the investigators that can interchange six different instrument tips through the tool's shaft, the range of tool change times is approximately 11-13 s. Using this figure, estimated time savings for the procedures analyzed ranged from 2.5 to over 32 min, and on average, total surgery time can be reduced by almost 17% by using the multifunction tool.

  2. The scheduling of tracking times for interplanetary spacecraft on the Deep Space Network

    NASA Technical Reports Server (NTRS)

    Webb, W. A.

    1978-01-01

    The Deep Space Network (DSN) is a network of tracking stations, located throughout the globe, used to track spacecraft for NASA's interplanetary missions. This paper describes a computer program, DSNTRAK, which provides an optimum daily tracking schedule for the DSN given the view periods at each station for a mission set of n spacecraft, where n is between 2 and 6. The objective function is specified in terms of relative total daily tracking time requirements between the n spacecraft. Linear programming is used to maximize the total daily tracking time and determine an optimal daily tracking schedule consistent with DSN station capabilities. DSNTRAK is used as part of a procedure to provide DSN load forecasting information for proposed future NASA mission sets.

  3. Frey procedure for surgical management of chronic pancreatitis in children.

    PubMed

    Rollins, Michael D; Meyers, Rebecka L

    2004-06-01

    The authors adopted the Frey procedure for the surgical management of chronic pancreatitis after one of their patients had recurrent disease in the head of the gland after a longitudinal pancreaticojejunostomy (LPJ or modified Puestow procedure). This is the first description of its use in children. A retrospective chart review was performed of all children undergoing a drainage or resection procedure for chronic pancreatitis from 1995 to 2002. Eleven children (6 boys, 5 girls, ages 8 to 18 years) underwent either the LPJ (3) or Frey (8) procedure. Etiologies included: idiopathic (5), familial (2), congenital anomaly of the major papilla (1), pancreatic head mass (1), short bowel syndrome (1), and pancreatic divisum (1). Before surgical therapy, patients had been symptomatic 2.3 years (range, 1 month to 6 years) and had been hospitalized for pancreatitis 4 times (range, 1 to 10). Four patients did not respond to endoscopic stenting, and 5 had a pancreatic pseudocyst. Patients were followed up in clinic an average of 2.5 years, with total time elapsed since surgery averaging 4.6 years. Eight of 11 patients experienced excellent or good results subsequent to surgical intervention. The Frey procedure is effective for children who have not responded to conservative management of chronic pancreatitis and may prevent recurrent disease in the head of the gland.

  4. Neither pre-operative education or a minimally invasive procedure have any influence on the recovery time after total hip replacement.

    PubMed

    Biau, David Jean; Porcher, Raphael; Roren, Alexandra; Babinet, Antoine; Rosencher, Nadia; Chevret, Sylvie; Poiraudeau, Serge; Anract, Philippe

    2015-08-01

    The purpose of this study was to evaluate pre-operative education versus no education and mini-invasive surgery versus standard surgery to reach complete independence. We conducted a four-arm randomized controlled trial of 209 patients. The primary outcome criterion was the time to reach complete functional independence. Secondary outcomes included the operative time, the estimated total blood loss, the pain level, the dose of morphine, and the time to discharge. There was no significant effect of either education (HR: 1.1; P = 0.77) or mini-invasive surgery (HR: 1.0; 95 %; P = 0.96) on the time to reach complete independence. The mini-invasive surgery group significantly reduced the total estimated blood loss (P = 0.0035) and decreased the dose of morphine necessary for titration in the recovery (P = 0.035). Neither pre-operative education nor mini-invasive surgery reduces the time to reach complete functional independence. Mini-invasive surgery significantly reduces blood loss and the need for morphine consumption.

  5. Biomonitoring of carcinogenic substances: enzymatic digestion of globin for detecting alkylated amino acids

    NASA Astrophysics Data System (ADS)

    Bader, Michael; Rauscher, Dankwart; Geibel, Kurt; Angerer, Juergen

    1993-03-01

    We report the application of proteases for the total hydrolysis of globin with subsequent determination of amino acids. Optimization of the proteolysis was made with respect to enzyme concentration, time of incubation and type of protease. Ethylene oxide modified globin was used to compare the results of the analysis of the N-terminal amino acid valine after enzymatic cleavage to those obtained from the widely used modified Edman procedure. It is shown that the cleavage is of good reproducibility and yields more alkylated amino acid than the Edman procedure.

  6. Resource Allocation in a Repetitive Project Scheduling Using Genetic Algorithm

    NASA Astrophysics Data System (ADS)

    Samuel, Biju; Mathew, Jeeno

    2018-03-01

    Resource Allocation is procedure of doling out or allocating the accessible assets in a monetary way and productive way. Resource allocation is the scheduling of the accessible assets and accessible exercises or activities required while thinking about both the asset accessibility and the total project completion time. Asset provisioning and allocation takes care of that issue by permitting the specialist co-ops to deal with the assets for every individual demand of asset. A probabilistic selection procedure has been developed in order to ensure various selections of chromosomes

  7. An Audiovisual Teaching Module to Assist Examiners in the Administration of a Practical Performance Examination for the Emergency Medical Technician-Ambulance (EMT-A). Consisting of a 90-Minute Audiovisual Presentation In Either 16mm Sound or 3/4" Video-Cassette Plus a "User's Guide" Describing in Detail the Total Examination Procedure. Final Report.

    ERIC Educational Resources Information Center

    National Registry of Emergency Medical Technicians, Columbus, OH.

    A structured, time-referenced, performance examination was designed as part of the certification procedure for Emergency Medical Technicians-Ambulance in an attempt to increase objectivity and standardization. This examination is based on a model developed by the University of Southern California, School of Medicine, Department of Emergency…

  8. Simulated procedure rehearsal is more effective than a preoperative generic warm-up for endovascular procedures.

    PubMed

    Willaert, Willem I M; Aggarwal, Rajesh; Daruwalla, Farhad; Van Herzeele, Isabelle; Darzi, Ara W; Vermassen, Frank E; Cheshire, Nicholas J

    2012-06-01

    Patient-specific simulated rehearsal (PsR) of a carotid artery stenting procedure (CAS) enables the interventionalist to rehearse the case before performing the procedure on the actual patient by incorporating patient-specific computed tomographic data into the simulation software. This study aimed to evaluate whether PsR of a CAS procedure can enhance the operative performance versus a virtual reality (VR) generic CAS warm-up procedure or no preparation at all. During a 10-session cognitive/technical VR course, medical residents were trained in CAS. Thereafter, in a randomized crossover study, each participant performed a patient-specific CAS case 3 times on the simulator, preceded by 3 different tasks: a PsR, a generic case, or no preparation. Technical performances were assessed using simulator-based metrics and expert-based ratings. Twenty medical residents (surgery, cardiology, radiology) were recruited. Training plateaus were observed after 10 sessions for all participants. Performances were significantly better after PsR than after a generic warm-up or no warm-up for total procedure time (16.3 ± 0.6 vs 19.7 ± 1.0 vs 20.9 ± 1.1 minutes, P = 0.001) and fluoroscopy time (9.3 ± 0.1 vs 11.2 ± 0.6 vs 11.2 ± 0.5 minutes, P = 0.022) but did not influence contrast volume or number of roadmaps used during the "real" case. PsR significantly improved the quality of performance as measured by the expert-based ratings (scores 28 vs 25 vs 25, P = 0.020). Patient-specific simulated rehearsal of a CAS procedure significantly improves operative performance, compared to a generic VR warm-up or no warm-up. This technology requires further investigation with respect to improved outcomes on patients in the clinical setting.

  9. Therapeutic peroral direct cholangioscopy using a single balloon enteroscope in patients with Roux-en-Y anastomosis (with videos).

    PubMed

    Yamauchi, Hiroshi; Kida, Mitsuhiro; Okuwaki, Kosuke; Miyazawa, Shiro; Matsumoto, Takaaki; Uehara, Kazuho; Miyata, Eiji; Hasegawa, Rikiya; Kaneko, Toru; Laopeamthong, Issaree; Lei, Yang; Iwai, Tomohisa; Imaizumi, Hiroshi; Koizumi, Wasaburo

    2018-01-01

    Peroral cholangioscopic lithotripsy is a useful procedure in patients with a normal gastrointestinal anatomy who have difficult-to-treat stones. We evaluated the usefulness of peroral direct cholangioscopy (PDCS) using single-balloon enteroscope (SBE) in patients with difficult-to-treat stones who had undergone Roux-en-Y reconstruction. Among 118 patients (169 sessions) who underwent SBE-assisted endoscopic retrograde cholangiopancreatography to treat biliary stones after Roux-en-Y reconstruction, patients in whom it was difficult to remove biliary stones via a transpapillary or transanastomotic approach and difficult to switch to ultra-slim endoscope, were retrospectively enrolled. The biliary insertion success rate, procedure success rate, procedure time, and procedural complications were assessed. The SBE was inserted into the bile-duct, first using a free-hand technique, second using a guide wire, and third using the large balloon anchoring and deflation (LBAD) technique. A total of 11 patients (14 sessions) were enrolled in this study. The biliary insertion success rate was 100%. Bile-duct insertion was performed using a free-hand technique in 4 sessions, a guide wire in 3 sessions (rendezvous technique, 2 sessions), and the LBAD technique in 7 sessions. The procedure success rate was 86% in first session, and 100% in second session. The median procedure time was 81 min (range 49-137). The median procedure time in the bile-duct was 21.5 min (range 6-60). Mild pancreatitis occurred as a complication in one patient. The median follow-up was 528 days (range 282-764). No patient had stone recurrence. PDCS using SBE is a useful procedure in patients with Roux-en-Y reconstruction. The LBAD technique is an useful technique of inserting SBE into the bile-duct.

  10. Non-fluoroscopic navigation systems for radiofrequency catheter ablation for supraventricular tachycardia reduce ionising radiation exposure.

    PubMed

    See, Jason; Amora, Jonah L; Lee, Sheldon; Lim, Paul; Teo, Wee Siong; Tan, Boon Yew; Ho, Kah Leng; Lee, Chee Wan; Ching, Chi-Keong

    2016-07-01

    The use of non-fluoroscopic systems (NFS) to guide radiofrequency catheter ablation (RFCA) for the treatment of supraventricular tachycardia (SVT) is associated with lower radiation exposure. This study aimed to determine if NFS reduces fluoroscopy time, radiation dose and procedure time. We prospectively enrolled patients undergoing RFCA for SVT. NFS included EnSiteTM NavXTM or CARTO® mapping. We compared procedure and fluoroscopy times, and radiation exposure between NFS and conventional fluoroscopy (CF) cohorts. Procedural success, complications and one-year success rates were reported. A total of 200 patients over 27 months were included and RFCA was guided by NFS for 79 patients; those with atrioventricular nodal reentrant tachycardia (AVNRT), left-sided atrioventricular reentrant tachycardia (AVRT) and right-sided AVRT were included (n = 101, 63 and 36, respectively). Fluoroscopy times were significantly lower with NFS than with CF (10.8 ± 11.1 minutes vs. 32.0 ± 27.5 minutes; p < 0.001). The mean fluoroscopic dose area product was also significantly reduced with NFS (NSF: 5,382 ± 5,768 mGy*cm2 vs. CF: 21,070 ± 23,311 mGy*cm2; p < 0.001); for all SVT subtypes. There was no significant reduction in procedure time, except for left-sided AVRT ablation (NFS: 79.2 minutes vs. CF: 116.4 minutes; p = 0.001). Procedural success rates were comparable (NFS: 97.5% vs. CF: 98.3%) and at one-year follow-up, there was no significant difference in the recurrence rates (NFS: 5.2% vs. CF: 4.2%). No clinically significant complications were observed in both groups. The use of NFS for RFCA for SVT is safe, with significantly reduced radiation dose and fluoroscopy time. Copyright © Singapore Medical Association.

  11. Impact of catheter ablation with remote magnetic navigation on procedural outcomes in patients with persistent and long-standing persistent atrial fibrillation.

    PubMed

    Jin, Qi; Pehrson, Steen; Jacobsen, Peter Karl; Chen, Xu

    2015-11-01

    The objectives of this study were to assess the procedural outcomes of persistent and long-standing persistent atrial fibrillation (PsAF and L-PsAF) ablation guided by remote magnetic navigation (RMN), and to detect factors predicting acute restoration of sinus rhythm (SR) by ablation with RMN. A total of 313 patients (275 male, age 59 ± 9.5 years) with PsAF (187/313) or L-PsAF (126/313) undergoing ablation using RMN were included. Patients' disease history, pulmonary venous anatomy, left atrial (LA) volume, procedure time, mapping plus ablation time, radiofrequency (RF) ablation time, fluoroscopy time, radiation dose, and complications were assessed. Stepwise regression was used to predict which variable could best predict acute restoration from AF to SR by ablation. Compared to PsAF, procedure time and RF ablation time were significantly increased in patients with L-PsAF (P = 0.01 and P < 0.001, respectively). No major complications occurred during the procedures in either PsAF or L-PsAF patients. Fifty five of 313 patients converted directly to SR by ablation. Compared to L-PsAF, the rate of SR restoration was significantly higher in PsAF (21 vs 12%, P = 0.03). Stepwise regression analysis showed LA volume was the primary parameter affecting SR restoration (P = 0.01). The LA volume of patients without direct SR restoration by ablation was 24% greater than that of patients with SR restoration (P < 0.001). Catheter ablation using RMN is a safe and effective method for PsAF and L-PsAF. LA volume could be a predictor of direct restoration of SR from sustaining AF by ablation using RMN.

  12. Long-Term Outcomes of Intestinal and Multivisceral Transplantation at a Single Center in Argentina.

    PubMed

    Ramisch, D; Rumbo, C; Echevarria, C; Moulin, L; Niveyro, S; Orce, G; Crivelli, A; Martinez, M I; Chavez, L; Paez, M A; Trentadue, J; Klein, F; Fernández, A; Solar, H; Gondolesi, G E

    2016-03-01

    Intestinal failure (IF) patients received parenteral nutrition (PN) as the only available therapy until intestinal transplantation (ITx) evolved as an accepted treatment. The aim of this article is to report the long-term outcomes of a series of ITx performed in pediatric and adult patients at a single center 9 years after its creation. This is a retrospective analysis of the ITx performed between May 2006 and January 2015. Diagnoses, pre-ITx mean time on PN, indications for ITx, time on the waiting list for types of ITx, mean total ischemia time, and warm ischemia time, time until PN discontinuation, incidence of acute and chronic rejection, and 5-year actuarial patient survival are reported. A total of 42 patients received ITx; 80% had short gut syndrome (SG); the mean time on PN was 1620 days. The main indication for ITx was lack of central venous access followed by intestinal failure-associated liver disease (IFALD) and catheter-related infectious complications. The mean time on the waiting list was 188 days (standard deviation, ±183 days). ITx were performed in 26 children and 14 adults. In all, 32 procedures were isolated ITx (IITX); 10 were multiorgan Tx (MOT; 3 combined, 7 multivisceral Tx (MVTx), 1 modified MVTx and 2 with kidney); 2 (4.7 %) were retransplantations: 1 IITx, 1 MVTx, and 5 including the right colon. Thirteen patients (31%) received abdominal rectus fascia. All procedures were performed by the same surgical team. Total ischemia time was 7:53 ± 2:04 hours, and warm ischemia time was 40.2 ± 10.5 minutes. The mean length of implanted intestine was 325 ± 63 cm. Bishop-Koop ileostomy was performed in 67% of cases. In all, 16 of 42 Tx required early reoperations. The overall mean follow-up time was 41 ± 35.6 months. The mean time to PN discontinuation after Tx was 68 days (P = .001). The total number of acute cellular rejection (ACR) episodes until the last follow-up was 83; the total number of grafts lost due to ACR was 4; and the total graft lost due to chronic rejection was 3. At the time of writing, the overall 5-year patient survival is 55% (65% for IITx vs 22% for MOT; P = .0001); 60% for pediatric recipients vs 47% for adults (P = NS); 64% when the indication for ITx was SG vs 25% for non-SG (P = .002). At this center, candidates with SG, in the absence of IFALD requiring IITx, showed the best long-term outcomes, independent of recipient age. A multidisciplinary approach is mandatory for the care of intestinal failure patients, to sustain a rehabilitation and transplantation program over time. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Robotic Single-Site and Conventional Laparoscopic Surgery in Gynecology: Clinical Outcomes and Cost Analysis of a Matched Case-Control Study.

    PubMed

    El Hachem, Lena; Andikyan, Vaagn; Mathews, Shyama; Friedman, Kathryn; Poeran, Jashvant; Shieh, Kenneth; Geoghegan, Michael; Gretz, Herbert F

    2016-01-01

    To assess the clinical outcomes and costs associated with robotic single-site (RSS) surgery compared with those of conventional laparoscopy (CL) in gynecology. Retrospective case-control study (Canadian Task Force classification II-2). University-affiliated community hospital. Female patients undergoing RSS or CL gynecologic procedures. Comparison of consecutive RSS gynecologic procedures (cases) undertaken between October 2013 and March 2014 with matched CL procedures (controls) completed during the same time period by the same surgeon. Patient demographic data, operative data, and hospital financial data were abstracted from the electronic charts and financial systems. An incremental cost analysis based on the use of disposable equipment was performed. Total hospital charges were determined for matched RSS cases vs CL cases. RSS surgery was completed in 25 out of 33 attempts; 3 cases were aborted before docking, and 5 were converted to a multisite surgery. There were no intraoperative complications or conversions to laparotomy. The completed cases included 11 adnexal cases and 14 hysterectomies, 3 of which included pelvic lymph node dissection. Compared with the CL group, total operative times were higher in the RSS group; however, there were no significant between-group differences in estimated blood loss, length of hospital stay, or complication rates. Disposable equipment cost per case, direct costs, and total hospital charges were evaluated. RSS was associated with an increased disposable cost per case of $248 to $378, depending on the method used for vaginal cuff closure. The average total hospital charges for matched outpatient adnexal surgery were $15,450 for the CL controls and $18,585 for the RSS cases (p < .001), and the average total hospital charges for matched outpatient benign hysterectomy were $14,623 for the CL controls and $21,412 for the RSS cases (p < .001). Although RSS surgery and CL have comparable clinical outcomes in selected patients, RSS surgery remains associated with increased incremental disposable cost per case and total hospital charges. Careful case selection and judicious use of equipment are necessary to maximize cost-effectiveness in RSS gynecologic surgery. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  14. Same-day colonoscopy preparation with Senna alkaloids and bisacodyl tablets: A pilot study

    PubMed Central

    Yenidogan, Erdinc; Okan, Ismail; Kayaoglu, Huseyin Ayhan; Akgul, Gokhan Giray; Sansal, Mufit; Tali, Servet; Ozsoy, Zeki; Sahin, Mustafa

    2014-01-01

    AIM: To evaluate the efficacy of same-day bowel preparation with Senna alkaloids combined with bisacodyl tablets in routine colonoscopy procedures. METHODS: Between March and June 2013, a same-day bowel preparation was implemented in our endoscopy unit. The preparation consisted of a semi-liquid, fiber-free diet one day prior to the procedure, with two bisacodyl tablets after lunch and dinner, and 250 mL of Senna alkaloid with 1.5 L of drinking water at 6 am the day of the procedure. The quality control parameters of colonoscopy were evaluated and implemented according to the guidelines of the American Society for Gastrointestinal Endoscopy. The pre-procedure, during-procedure and post-procedure patient data were collected and analyzed: (1) pre-procedure (age, gender, comorbid diseases, colonoscopy indications, complete lack of compliance with the bowel preparation protocol); (2) during-procedure (sedation dose, duration of colonoscopy, withdrawal time, cecal intubation rate, polyp detection rate, Boston Bowel Preparation Scores and presence of foam and clear liquid); and (3) post-procedure (visual analogue scale score, pain during the procedure, patient satisfaction and premature withdrawal due to the insufficient bowel preparation). RESULTS: A total of 75 patients were included in this study with a mean age of 54.64 ± 13.29 years; 53.3% (40/75) were female and 46.7% (35/75) were male. A complete lack of compliance with the bowel preparation protocol was seen in 6.7% of patients (5/75). The mean total duration of colonoscopy was 16.12 ± 6.51 min, and the mean withdrawal time was 8.89 ± 4.07 min. The cecal intubation rate was 93.8% (61/64) and the polyp detection rate was 40% (30/75). The mean Boston Bowel Preparation Score was 7.38 ± 1.81, with the following distribution: right colon, 2.34 ± 0.89; transverse colon, 2.52 ± 0.67; left colon, 2.52 ± 0.63. The mean visual analogue scale score was 4.59 ± 1.57. Due to insufficient bowel preparation, seven patients (7/75; 9.3%) were asked to repeat the procedure. Of these, five patients had poor or modest compliance with the protocol, and two patients reported constipation. Premature withdrawal due to insufficient bowel preparation was 2.7% (2/75). The overall satisfaction with the protocol was 86.7% (65/75), with patients reporting they would prefer the same protocol in a repeat procedure. CONCLUSION: The same-day administration of Senna alkaloids appears to be a safe and effective bowel cleansing protocol for colonoscopy procedures. PMID:25386088

  15. Same-day colonoscopy preparation with Senna alkaloids and bisacodyl tablets: a pilot study.

    PubMed

    Yenidogan, Erdinc; Okan, Ismail; Kayaoglu, Huseyin Ayhan; Akgul, Gokhan Giray; Sansal, Mufit; Tali, Servet; Ozsoy, Zeki; Sahin, Mustafa

    2014-11-07

    To evaluate the efficacy of same-day bowel preparation with Senna alkaloids combined with bisacodyl tablets in routine colonoscopy procedures. Between March and June 2013, a same-day bowel preparation was implemented in our endoscopy unit. The preparation consisted of a semi-liquid, fiber-free diet one day prior to the procedure, with two bisacodyl tablets after lunch and dinner, and 250 mL of Senna alkaloid with 1.5 L of drinking water at 6 am the day of the procedure. The quality control parameters of colonoscopy were evaluated and implemented according to the guidelines of the American Society for Gastrointestinal Endoscopy. The pre-procedure, during-procedure and post-procedure patient data were collected and analyzed: (1) pre-procedure (age, gender, comorbid diseases, colonoscopy indications, complete lack of compliance with the bowel preparation protocol); (2) during-procedure (sedation dose, duration of colonoscopy, withdrawal time, cecal intubation rate, polyp detection rate, Boston Bowel Preparation Scores and presence of foam and clear liquid); and (3) post-procedure (visual analogue scale score, pain during the procedure, patient satisfaction and premature withdrawal due to the insufficient bowel preparation). A total of 75 patients were included in this study with a mean age of 54.64 ± 13.29 years; 53.3% (40/75) were female and 46.7% (35/75) were male. A complete lack of compliance with the bowel preparation protocol was seen in 6.7% of patients (5/75). The mean total duration of colonoscopy was 16.12 ± 6.51 min, and the mean withdrawal time was 8.89 ± 4.07 min. The cecal intubation rate was 93.8% (61/64) and the polyp detection rate was 40% (30/75). The mean Boston Bowel Preparation Score was 7.38 ± 1.81, with the following distribution: right colon, 2.34 ± 0.89; transverse colon, 2.52 ± 0.67; left colon, 2.52 ± 0.63. The mean visual analogue scale score was 4.59 ± 1.57. Due to insufficient bowel preparation, seven patients (7/75; 9.3%) were asked to repeat the procedure. Of these, five patients had poor or modest compliance with the protocol, and two patients reported constipation. Premature withdrawal due to insufficient bowel preparation was 2.7% (2/75). The overall satisfaction with the protocol was 86.7% (65/75), with patients reporting they would prefer the same protocol in a repeat procedure. The same-day administration of Senna alkaloids appears to be a safe and effective bowel cleansing protocol for colonoscopy procedures.

  16. Thirty-day emergency room visits and hospital admissions after outpatient non-vascular image-guided procedures.

    PubMed

    Nguyen, Quang; Mehta, Sahil V; Fang, Jieming; Sheiman, Robert; Kane, Robert; Ahmed, Muneeb; Sarwar, Ammar; Siewert, Bettina; Brook, Olga R

    2017-10-01

    To evaluate the rate of post-procedure emergency department (ED) visits and hospital admissions following outpatient non-vascular image-guided interventions performed under moderate sedation and to identify common and preventable causes of emergency department visits and hospital admissions. Institutional review board approval was acquired for this HIPAA-compliant retrospective study with waiver of informed consent. 1426 consecutive patients undergoing 1512 outpatient image-guided procedures under moderate sedation from November 2012 to August 2014 were included. The average patient age was 57.2 ± 15.2 years, and 602 (42%) patients were women. Major procedure categories included ultrasound-guided liver biopsies, ultrasound-guided kidney biopsies, and CT-guided lung biopsies/fiducial placement. Procedure details and medical follow-up within and after 30 days of the procedure were analyzed. A total of 168 (11.8%) patients were admitted to the hospital within 30 days of the procedure, with 29 of the admissions (17.3% of total admissions and 1.9% of total procedures) being procedure related. The most common procedure-related complication that required admission was hemorrhage (10/29, 34.5% of procedure-related admissions, 6.0% of total admissions, and 0.7% of total procedures), followed by pneumothorax (9/29, 31%, 5.4%, 0.6%), infection (4/29, 13.8%, 2.4%, 0.3%), and pain (3/29, 10.3%, 1.8%, 0.2%). Eighteen (62.1%) procedure-related admissions were immediately indicated. Thirty patients visited the ED and were subsequently discharged without admission with eight of the visits being procedure related (8/1512, 0.5%). All the procedure-related ED visits were due to pain. There were two deaths (2/1512, 0.1%) related to procedures, one from a thromboembolic event and another from post-biopsy hemorrhage. Outpatient non-vascular image-guided procedures result in a 30-day 1.9% hospital admission, 30-day 0.5% emergency room visit, and 30-day 0.1% mortality rate.

  17. Intradural Procedural Time to Assess Technical Difficulty of Superciliary Keyhole and Pterional Approaches for Unruptured Middle Cerebral Artery Aneurysms

    PubMed Central

    Choi, Yeon-Ju; Son, Wonsoo; Park, Ki-Su

    2016-01-01

    Objective This study used the intradural procedural time to assess the overall technical difficulty involved in surgically clipping an unruptured middle cerebral artery (MCA) aneurysm via a pterional or superciliary approach. The clinical and radiological variables affecting the intradural procedural time were investigated, and the intradural procedural time compared between a superciliary keyhole approach and a pterional approach. Methods During a 5.5-year period, patients with a single MCA aneurysm were enrolled in this retrospective study. The selection criteria for a superciliary keyhole approach included : 1) maximum diameter of the unruptured MCA aneurysm <15 mm, 2) neck diameter of the MCA aneurysm <10 mm, and 3) aneurysm location involving the sphenoidal or horizontal segment of MCA (M1) segment and MCA bifurcation, excluding aneurysms distal to the MCA genu. Meanwhile, the control comparison group included patients with the same selection criteria as for a superciliary approach, yet who preferred a pterional approach to avoid a postoperative facial wound or due to preoperative skin trouble in the supraorbital area. To determine the variables affecting the intradural procedural time, a multiple regression analysis was performed using such data as the patient age and gender, maximum aneurysm diameter, aneurysm neck diameter, and length of the pre-aneurysm M1 segment. In addition, the intradural procedural times were compared between the superciliary and pterional patient groups, along with the other variables. Results A total of 160 patients underwent a superciliary (n=124) or pterional (n=36) approach for an unruptured MCA aneurysm. In the multiple regression analysis, an increase in the diameter of the aneurysm neck (p<0.001) was identified as a statistically significant factor increasing the intradural procedural time. A Pearson correlation analysis also showed a positive correlation (r=0.340) between the neck diameter and the intradural procedural time. When comparing the superciliary and pterional groups, no statistically significant between-group difference was found in terms of the intradural procedural time reflecting the technical difficulty (mean±standard deviation : 29.8±13.0 min versus 27.7±9.6 min). Conclusion A superciliary keyhole approach can be a useful alternative to a pterional approach for an unruptured MCA aneurysm with a maximum diameter <15 mm and neck diameter <10 mm, representing no more of a technical challenge. For both surgical approaches, the technical difficulty increases along with the neck diameter of the MCA aneurysm. PMID:27847568

  18. Procedural Portfolio Planning in Plastic Surgery, Part 2: Collaboration Between Surgeons and Hospital Administrators to Develop a Funds Flow Model for Procedures Performed at an Academic Medical Center.

    PubMed

    Hultman, Charles Scott

    2016-06-01

    Although plastic surgeons make important contributions to the clinical, educational, and research missions of academic medical centers (AMCs), determining the financial value of a plastic surgery service can be difficult, due to complex cost accounting systems. We analyzed the financial impact of plastic surgery on an AMC, by examining the contribution margins and operating income of surgical procedures. We collaborated with hospital administrators to implement 3 types of strategic changes: (1) growth of areas with high contribution margin, (2) curtailment of high-risk procedures with negative contribution margin, (3) improved efficiency of mission-critical services with high resource consumption. Outcome measures included: facility charges, hospital collections, contribution margin, operating margin, and operating room times. We also studied the top 50 Current Procedural Terminology codes (total case number × charge/case), ranking procedures for profitability, as determined by operating margin. During the 2-year study period, we had no turnover in faculty; did not pursue any formal marketing; did not change our surgical fees, billing system, or payer mix; and maintained our commitment to indigent care. After rebalancing our case mix, through procedural portfolio planning, average hospital operating income/procedure increased from $-79 to $+816. Volume and diversity of cases increased, with no change in payer mix. Although charges/case decreased, both contribution margin and operating margin increased, due to improved throughput and decreased operating room times. The 5 most profitable procedures for the hospital were hernia repair, mandibular osteotomy, hand skin graft, free fibula flap, and head and neck flap, whereas the 5 least profitable were latissimus breast reconstruction, craniosynostosis repair, free-flap breast reconstruction, trunk skin graft, and cutaneous free flap. Total operating income for the hospital, from plastic surgery procedures, increased from $-115,103 to $+1,277,040, of which $350,000 (25%) was returned to the practice plan as enterprise funds to support program development. Through focused strategic initiatives, plastic surgeons and hospital administrators can work together to unlock the latent value of a plastic surgery service to an AMC. Specific financial benefits to the hospital include increased contribution margin and operating income, the latter of which can be reinvested in the plastic surgery service through a gain-sharing model.

  19. Total photoionization cross sections of atomic oxygen from threshold to 44.3 A

    NASA Technical Reports Server (NTRS)

    Angel, G. C.; Samson, James A. R.

    1988-01-01

    Synchrotron radiation was used to obtain the relative photoionization cross section of atomic oxygen for the production of singly charged ions over the 44.3-910.5-A wavelength range. Measurement of the contribution of multiple ionization to the cross sections has made possible the determination of total photoionization cross sections below 250 A. The series of autoionizing resonances leading to the 4P state of the oxygen ion has been observed using an ionization-type experimental procedure for the first time.

  20. Manipulation under Anesthesia for Stiffness after Total Knee Arthroplasty

    PubMed Central

    Yoo, Ju-Hyung; Oh, Jin-Cheol; Park, Sang-Hoon

    2015-01-01

    Purpose This study evaluated the incidence of manipulation under anesthesia (MUA) for stiffness after total knee arthroplasty (TKA) and the degree of joint motion recovery after MUA. Materials and Methods A total of 4,449 TKAs (2,973 patients) were performed between March 2000 and August 2014. Cases that underwent MUA for stiffness after TKA were reviewed. TKAs were performed using the conventional procedure in 329 cases and using the minimally invasive procedure in 4,120 cases. The preoperative range of joint motion, timing of manipulation, diagnosis and the range of joint motion before and after MUA were retrospectively investigated. Results MUA was carried out in 22 cases (16 patients), resulting in the incidence of 0.5%. The incidence after the conventional procedure was 1.2% and 0.4% after the minimally invasive procedure. In the manipulated knees, the preoperative range of motion (ROM) was 102.5°±26.7°, and the preoperative diagnosis was osteoarthritis in 19 cases, rheumatoid arthritis in two, and infection sequela in one. MUA was performed 4.7±3.0 weeks after TKA. The average ROM was 64.5°±13.5° before manipulation. At an average of 64.3±41.3 months after manipulation, the ROM was recovered to 113.4°±31.2°, which was an additional 49.9° improvement in flexion. Conclusions The satisfactory recovery of joint movement was achieved when MUA for stiffness was performed relatively early after TKA. PMID:26676186

  1. Orthopedic surgery in rheumatoid arthritis in the era of biologic therapy.

    PubMed

    Leon, Leticia; Abasolo, Lydia; Carmona, Loreto; Rodriguez-Rodriguez, Luis; Lamas, Jose Ramon; Hernandez-Garcia, Cesar; Jover, Juan Angel

    2013-11-01

    To analyze sociodemographic and clinic-related factors associated with the use of orthopedic surgical procedures in rheumatoid arthritis (RA), focusing on the potential role of new biologic therapies. A retrospective medical record review was performed in a probability sample of 1272 patients with RA from 47 units distributed in 19 Spanish regions. Sociodemographic and clinical features, use of drugs, and arthritis-related joint surgeries were recorded following a standardized protocol. A total of 94 patients (7.4%) underwent any orthopedic surgery during their disease course, with a total of 114 surgeries; 47 (41.2%) of these surgeries were total joint replacement (TJR). The median time to first orthopedic procedure was 7.9 years from the onset of RA symptoms, and the rate of orthopedic surgery (excluding TJR) was 4.5 procedures per 100 person-years from the beginning of RA, while the rate of TJR was 2.25 interventions per 100 person-years. A higher risk of undergoing an orthopedic surgical procedure was associated with taking nonsteroidal antiinflammatory drugs (NSAID) in the previous 2 years, female sex, longterm disease, and the presence of extraarticular complications. The risk factors for undergoing a TJR were being old, having a longterm disease, and taking biologic therapies. In the era of biologics, our national audit found a low percentage of patients who underwent orthopedic surgery, probably reflecting a thorough management of the RA. Sociodemographic factors, longterm RA, extraarticular complications, and NSAID were associated with orthopedic surgery.

  2. Introducing laparoscopic total gastrectomy for gastric cancer in general practice: a retrospective cohort study based on a nationwide registry database in Japan.

    PubMed

    Kodera, Yasuhiro; Yoshida, Kazuhiro; Kumamaru, Hiraku; Kakeji, Yoshihiro; Hiki, Naoki; Etoh, Tsuyoshi; Honda, Michitaka; Miyata, Hiroaki; Yamashita, Yuichi; Seto, Yasuyuki; Kitano, Seigo; Konno, Hiroyuki

    2018-02-09

    Although laparoscopic total gastrectomy (LTG) is considered a technically demanding procedure with safety issues, it has been performed in several hospitals in Japan. Data from a nationwide web-based data entry system for surgical procedures (NCD) that started enrollment in 2011 are now available for analysis. A retrospective cohort study was conducted using data from 32,144 patients who underwent total gastrectomy and were registered in the NCD database between January 2012 and December 2013. Mortality and morbidities were compared between patients who received LTG and those who underwent open total gastrectomy (OTG) in the propensity score-matched Stage I cohort and Stage II-IV cohort. There was no significant difference in mortality rate between LTG and OTG in both cohorts. Operating time was significantly longer in LTG while the blood loss was smaller. In the Stage I cohort, LTG, performed in 33.6% of the patients, was associated with significantly shorter hospital stay but significantly higher incidence of readmission, reoperation, and anastomotic leakage (5.4% vs. 3.6%, p < 0.01). In the Stage II-IV cohort, LTG was performed in only 8.8% of the patients and was associated with significantly higher incidence of leakage (5.7% vs. 3.6%, p < 0.02) although the hospital stay was shorter (15 days vs. 17 days, p < 0.001). LTG was more discreetly introduced than distal gastrectomy, but remained a technically demanding procedure as of 2013. This procedure should be performed only among the well-trained and informed laparoscopic team.

  3. Development of neurosurgery in Germany: comparison of data collected by polls for 1997, 2003, and 2008 among providers of neurosurgical care.

    PubMed

    Steiger, Hans J; Krämer, Michael; Reulen, Hans J

    2012-01-01

    To deduce structural trends in neurosurgery in Germany by comparison of data derived from polls conducted by the Deutsche Gesellschaft für Neurochirurgie (DGNC) in 1997, 2003 and 2008. The questionnaires of the different polls probed a comparable set of issues. The data from the responding sample were extrapolated to the nationwide average or sum and compared between the different time periods. The number of identified neurosurgical departments increased from 146 to 201 during the years 1997-2008 largely as a result of the new foundation of numerous private groups. Nationwide total neurosurgical bed capacity and intensive care unit bed capacity increased modestly over the time period. The extrapolated total number of neurosurgical operations increased from 196,341 to 319,295. Although cranial and spinal neurosurgery remain the dominant subspecialties, the number of functional neurosurgical procedures and operations for pain increased more than proportionally. Outpatient procedures were established during the time period and corresponded in 2008 to a substantial proportion of the surgical volume. The total number of residents and board-certified neurosurgeons increased during the period 1997-2008 from 1513 to 1961. The proportion of residents decreased during 1997-2003 and then increased again. The number of neurosurgical operations increased in Germany proportionally to the economic growth of other service branches over the time period. Private organizations developed more than neurosurgical departments at university and other general hospitals. Work density measured as operations per physician increased during the period 1997-2008. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Does speed matter? The impact of operative time on outcome in laparoscopic surgery

    PubMed Central

    Jackson, Timothy D.; Wannares, Jeffrey J.; Lancaster, R. Todd; Rattner, David W.

    2012-01-01

    Introduction Controversy exists concerning the importance of operative time on patient outcomes. It is unclear whether faster is better or haste makes waste or similarly whether slower procedures represent a safe, meticulous approach or inexperienced dawdling. The objective of the present study was to determine the effect of operative time on 30-day outcomes in laparoscopic surgery. Methods Patients who underwent laparoscopic general surgery procedures (colectomy, cholecystectomy, Nissen fundoplication, inguinal hernia, and gastric bypass) from the ACS-NSQIP 2005–2008 participant use file were identified. Exclusion criteria were defined a priori to identify same-day admission, elective procedures. Operative time was divided into deciles and summary statistics were analyzed. Univariate analyses using a Cochran-Armitage test for trend were completed. The effect of operative time on 30-day morbidity was further analyzed for each procedure type using multivariate regression controlling for case complexity and additional patient factors. Patients within the highest deciles were excluded to reduce outlier effect. Results A total of 76,748 elective general surgical patients who underwent laparoscopic procedures were analyzed. Univariate analyses of deciles of operative time demonstrated a statistically significant trend (p \\ 0.0001) toward increasing odds of complications with increasing operative time for laparoscopic colectomy (n = 10,135), cholecystectomy (n = 37,407), Nissen fundoplication (n = 4,934), and gastric bypass (n = 17,842). The trend was not found to be significant for laparoscopic inguinal hernia repair (n = 6,430; p = 0.14). Multivariate modeling revealed the effect of operative time to remain significant after controlling for additional patient factors. Conclusion Increasing operative time was associated with increased odds of complications and, therefore, it appears that speed may matter in laparoscopic surgery. These analyses are limited in their inability to adjust for all patient factors, potential confounders, and case complexities. Additional hierarchical multivariate analyses at the surgeon level would be important to examine this relationship further. PMID:21298533

  5. Does speed matter? The impact of operative time on outcome in laparoscopic surgery.

    PubMed

    Jackson, Timothy D; Wannares, Jeffrey J; Lancaster, R Todd; Rattner, David W; Hutter, Matthew M

    2011-07-01

    Controversy exists concerning the importance of operative time on patient outcomes. It is unclear whether faster is better or haste makes waste or similarly whether slower procedures represent a safe, meticulous approach or inexperienced dawdling. The objective of the present study was to determine the effect of operative time on 30-day outcomes in laparoscopic surgery. Patients who underwent laparoscopic general surgery procedures (colectomy, cholecystectomy, Nissen fundoplication, inguinal hernia, and gastric bypass) from the ACS-NSQIP 2005-2008 participant use file were identified. Exclusion criteria were defined a priori to identify same-day admission, elective procedures. Operative time was divided into deciles and summary statistics were analyzed. Univariate analyses using a Cochran-Armitage test for trend were completed. The effect of operative time on 30-day morbidity was further analyzed for each procedure type using multivariate regression controlling for case complexity and additional patient factors. Patients within the highest deciles were excluded to reduce outlier effect. A total of 76,748 elective general surgical patients who underwent laparoscopic procedures were analyzed. Univariate analyses of deciles of operative time demonstrated a statistically significant trend (p<0.0001) toward increasing odds of complications with increasing operative time for laparoscopic colectomy (n=10,135), cholecystectomy (n=37,407), Nissen fundoplication (n=4,934), and gastric bypass (n=17,842). The trend was not found to be significant for laparoscopic inguinal hernia repair (n=6,430; p=0.14). Multivariate modeling revealed the effect of operative time to remain significant after controlling for additional patient factors. Increasing operative time was associated with increased odds of complications and, therefore, it appears that speed may matter in laparoscopic surgery. These analyses are limited in their inability to adjust for all patient factors, potential confounders, and case complexities. Additional hierarchical multivariate analyses at the surgeon level would be important to examine this relationship further.

  6. Renal sympathetic denervation increases renal blood volume per cardiac cycle: a serial magnetic resonance imaging study in resistant hypertension.

    PubMed

    Delacroix, Sinny; Chokka, Ramesh G; Nelson, Adam J; Wong, Dennis T; Sidharta, Samuel; Pederson, Stephen M; Rajwani, Adil; Nimmo, Joanne; Teo, Karen S; Worthley, Stephen G

    2017-01-01

    Preclinical studies have demonstrated improvements in renal blood flow after renal sympathetic denervation (RSDN); however, such effects are yet to be confirmed in patients with resistant hypertension. Herein, we assessed the effects of RSDN on renal artery blood flow and diameter at multiple time points post-RSDN. Patients (n=11) with systolic blood pressures ≥160 mmHg despite taking three or more antihypertensive medications at maximum tolerated dose were recruited into this single-center, prospective, non-blinded study. Magnetic resonance imaging indices included renal blood flow and renal artery diameters at baseline, 1 month and 6 months. In addition to significant decreases in blood pressures ( p <0.0001), total volume of blood flow per cardiac cycle increased by 20% from 6.9±2 mL at baseline to 8.4±2 mL ( p =0.003) at 1 month and to 8.0±2 mL ( p =0.04) 6 months post-procedure, with no changes in the renal blood flow. There was a significant decrease in renal artery diameters from 7±2 mm at baseline to 6±1 mm ( p =0.03) at 1 month post-procedure. This decrease was associated with increases in maximum velocity of blood flow from 73±20 cm/s at baseline to 78±19 cm/s at 1 month post-procedure. Notably, both parameters reverted to 7±2 mm and 72±18 cm/s, respectively, 6 months after procedure. RSDN improves renal physiology as evidenced by significant improvements in total volume of blood flow per cardiac cycle. Additionally, for the first time, we identified a transient decrease in renal artery diameters immediately after procedure potentially caused by edema and inflammation that reverted to baseline values 6 months post-procedure.

  7. Retrospective review of Contura HDR breast cases to improve our standardized procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iftimia, Ileana, E-mail: Ileana.n.iftimia@lahey.org; Cirino, Eileen T.; Ladd, Ron

    2013-07-01

    To retrospectively review our first 20 Contura high dose rate breast cases to improve and refine our standardized procedure and checklists. We prepared in advance checklists for all steps, developed an in-house Excel spreadsheet for second checking the plan, and generated a procedure for efficient contouring and a set of optimization constraints to meet the dose volume histogram criteria. Templates were created in our treatment planning system for structures, isodose levels, optimization constraints, and plan report. This study reviews our first 20 high dose rate Contura breast treatment plans. We followed our standardized procedure for contouring, planning, and second checking.more » The established dose volume histogram criteria were successfully met for all plans. For the cases studied here, the balloon-skin and balloon-ribs distances ranged between 5 and 43 mm and 1 and 33 mm, respectively; air{sub s}eroma volume/PTV{sub E}val volume≤5.5% (allowed≤10%); asymmetry<1.2 mm (goal≤2 mm); PTV{sub E}val V90%≥97.6%; PTV{sub E}val V95%≥94.9%; skin max dose≤98%Rx; ribs max dose≤137%Rx; V150%≤29.8 cc; V200%≤7.8 cc; the total dwell time range was 225.4 to 401.9 seconds; and the second check agreement was within 3%. Based on this analysis, more appropriate ranges for the total dwell time and balloon diameter tolerance were found. Three major problems were encountered: balloon migration toward the skin for small balloon-to-skin distances, lumen obstruction, and length change for the flexible balloon. Solutions were found for these issues and our standardized procedure and checklists were updated accordingly. Based on our review of these cases, the use of checklists resulted in consistent results, indicating good coverage for the target without sacrificing the critical structures. This review helped us to refine our standardized procedure and update our checklists.« less

  8. Combined effects of uncertainty and organizational justice on employee health: testing the uncertainty management model of fairness judgments among Finnish public sector employees.

    PubMed

    Elovainio, Marko; van den Bos, Kees; Linna, Anne; Kivimäki, Mika; Ala-Mursula, Leena; Pentti, Jaana; Vahtera, Jussi

    2005-12-01

    We examined whether the combination of uncertainty (lack of work-time control, and negative changes at work) and organizational justice (i.e., justice of decision-making procedures and interpersonal treatment at work) contributes to sickness absence. A total of 7083 male and 24,317 female Finnish public sector employees completed questionnaires designed to assess organizational justice, workload and other factors. Hierarchical regression showed that after adjustment for age, income, and health behaviors low procedural and interactional justice were related to long sickness absence spells. In accordance with the uncertainty management model, these associations were dependent on experienced work-time control and perceived changes at work.

  9. Determination of Total Solids and Ash in Algal Biomass: Laboratory Analytical Procedure (LAP)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Wychen, Stefanie; Laurens, Lieve M. L.

    2016-01-13

    This procedure describes the methods used to determine the amount of moisture or total solids present in a freeze-dried algal biomass sample, as well as the ash content. A traditional convection oven drying procedure is covered for total solids content, and a dry oxidation method at 575 deg. C is covered for ash content.

  10. Missed surgical intensive care unit billing: potential financial impact of 24/7 faculty presence.

    PubMed

    Hendershot, Kimberly M; Bollins, John P; Armen, Scott B; Thomas, Yalaunda M; Steinberg, Steven M; Cook, Charles H

    2009-07-01

    To efficiently capture evaluation and management (E&M) and procedural billing in our surgical intensive care unit (SICU), we have developed an electronic billing system that links to the electronic medical record (EMR). In this system, only notes electronically signed and coded by an attending generate billing charges. We hypothesized that capture of missed billing during nighttime and weekends might be sufficient to subsidize 24/7 in-house attending coverage. A retrospective chart EMR review was performed of the EMRs for all SICU patients during a 2-month period. Note type, date, time, attending signature, and coding were analyzed. Notes without attending signature, diagnosis, or current procedural terminology (CPT) code were considered incomplete and identified as "missed billing." Four hundred and forty-three patients had 465 admissions generating 2,896 notes. Overall, 76% of notes were signed and coded by an attending and billed. Incomplete (not billed) notes represented an overall missed billing opportunity of $159,138 for the 2-month time period (approximately $954,000 annually). Unbilled E&M encounters during weekdays totaled $54,758, whereas unbilled E&M and procedures from weeknights and weekends totaled $88,408 ($44,566 and $43,842, respectively). Missed billing after-hours thus represents approximately $530K annually, extrapolating to approximately $220K in collections from our payer mix. Surprisingly, missed E&M and procedural billing during weekdays totaled $70,730 (approximately $425K billing, approximately $170K collections annually), and typically represented patients seen, but transferred from the SICU before attending documentation was completed. Capture of nighttime and weekend ICU collections alone may be insufficient to add faculty or incentivize in-house coverage, but could certainly complement other in-house derived revenues to such ends. In addition, missed daytime billing in busy modern ICUs can be substantial, and use of an EMR to identify missed billing opportunities can help create solutions to recover these revenues.

  11. Adjustable Perineal Male Sling for the Treatment of Urinary Incontinence: Long-term Results.

    PubMed

    Altan, Mesut; Asi, Tariq; Bilen, Cenk Yucel; Ergen, Ali

    2017-08-01

    To present the long-term results in patients with urinary incontinence who were treated with adjustable perineal male sling. An adjustable male sling procedure was performed in 45 patients with a mean age of 67.6 ± 7.8 years who had urinary incontinence. The mean period between primary prostatic surgery and the sling procedure was 36.7 months. The difference between the classical sling and the adjustable one is a 10 cm tissue expander between the 2 layers of polypropylene mesh with an injection port. Adjustment of the sling was performed with saline via this port, in case of recurrence or persistence of incontinence. Mean follow-up was 48 ± 29 months. Average operative time was 101.1 ± 25.5 minutes (45-150). Median daily pad use in these patients decreased from 8(2-12) to 1(0-10) (P < .001). During long-term follow-up 37.8% used 0 pad daily, 28.9% used 1-2 pads daily, making the total success rate 66.7%. Complete dry rate was higher in patients with nonsevere incontinence compared to the others with severe incontinence (57.9% vs 23.1%, P = .029). Nevertheless, there was no significant difference in the case of total success rate (78.9% vs 57.7%, respectively; P = .135). Age was significantly greater in both complete dry group (71.1 ± 4.8 vs 65.4 ± 8.7) and total success group (70.1 ± 5.2 vs 62.4 ± 5.2) (P = .017 and P < .001, respectively). Adjustable male sling is an acceptable procedure with low complication rates especially in patients with mild and moderate incontinence. At the same time, this procedure may be offered to patients with previous incontinence surgery. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Feasibility and Learning Curve of Robotic Laparoendoscopic Single-Site Surgery in Gynecology.

    PubMed

    Buckley de Meritens, Alexandre; Kim, Julia; Dinkelspiel, Helen; Chapman-Davis, Eloise; Caputo, Thomas; Holcomb, Kevin M

    2017-02-01

    Single-site laparoscopy has proven to be a desirable option for patients undergoing gynecologic surgery, with some studies indicating improved cosmesis and less perioperative pain compared with standard approaches. This study describes the safety and feasibility of a novel robotic laparoendoscopic single-site surgery (R-LESS) platform as it is incorporated into a surgeon's practice with extensive multiport robotic surgical experience but limited LESS experience. We reviewed 83 women undergoing R-LESS by a single surgeon from September 2013 through August 2015. Operative times (total operative time, console time, docking time) were collected prospectively for the first 53 cases, and total operative time was collected retrospectively for the next 30 cases. Clinical parameters, including age, estimated blood loss, body mass index (BMI), prior abdominal surgeries, conversion to laparotomy, procedure type, uterine weight, length of hospital stay, and complications, were retrospectively collected from medical charts. Eighty-two of 83 surgeries were completed successfully with a single incision. One surgery was converted to multiport robotics for para-aortic lymph node dissection. Twelve surgeries were performed for cancer (ovary 1, uterus 8, and cervix 3). Eight patients underwent pelvic lymph node biopsy. The median total operative time for hysterectomies was 128 minutes (range, 60-275). After the first 13 hysterectomies the total operative time and the console time decreased significantly from 165.3 to 131.1 minutes (p = .032) and from 84.9 to 57.1 minutes (p = .028), respectively. Mean docking time halved from 7.8 minutes to 3.4 minutes comparing the first 10 cases to the last 10 cases. Surgical times were longer with larger BMIs, but the console time decreased with experience regardless of BMI. The mean uterine weight was 164 g (range, 30-460). Complications included 2 umbilical hernias (2.4%) and 1 conversion to multiport. In conclusion, R-LESS is a feasible and safe surgical platform for gynecologic procedures. A small number of cases are needed to significantly improve operative times when it is introduced on a surgeon's practice with limited experience in LESS but familiar with robotic surgery. Further study is needed to investigate the cost, benefits, and long-term outcomes of R-LESS. Published by Elsevier Inc.

  13. A New Way for Antihelixplasty in Prominent Ear Surgery: Modified Postauricular Fascial Flap.

    PubMed

    Taş, Süleyman; Benlier, Erol

    2016-06-01

    Otoplasty procedures aim to reduce the concha-mastoid angle and recreate the antihelical fold. Here, we explained the modified postauricular fascial flap, described as a new way for recreating the antihelical fold, and reported the results of patients on whom this flap was used. The defined technique was used on 24 patients (10 females and 14 males; age, 6-27 years; mean, 16.7 years) between June 2009 and July 2012, a total of 48 procedures in total (bilateral). Follow-up ranged from 1 to 3 years (mean, 1.5 years). At the preoperative and postoperative time points (1 and 12 months after surgery), all patients were measured for upper and middle helix-head distance and were photographed. The records were analyzed statistically using t test and analysis of variance. The procedure resulted in ears that were natural in appearance without any significant visible evidence of surgery. The operations resulted in no complications except 1 patient who developed a small skin ulcer on the left ear because of band pressure. When we compared the preoperative and postoperative upper and middle helix-head distance, there was a high significance statistically. To introduce modified postauricular fascial flap, we used a simple and safe procedure to recreate an antihelical fold. This procedure led to several benefits, including a natural-in-appearance antihelical fold, prevention of suture extrusion and granuloma, as well as minimized risk for recurrence due to neochondrogenesis. This method may be used as a standard procedure for treating prominent ears surgically.

  14. Double-balloon endoscopy for retrograde cholangiography in patients with choledochojejunostomy and Roux-en-Y reconstruction.

    PubMed

    Pohl, J; May, A; Aschmoneit, I; Ell, C

    2009-02-01

    Choledochojejunal anastomoses with Roux-en-Y reconstruction excludes the biliary tract from conventional endoscopic retrograde cholangiography (ERC) with standard endoscopes due to the length of the interposed small bowel segment. Double-balloon enteroscopy (DBE) facilitates deep insertion into the small bowel and may be used to perform ERC in these patients. In the present case series we report our experience with diagnostic and therapeutic double-balloon ERC in patients with choledochojejunostomy to a long Roux-en-Y loop previously unavailable for standard length endoscopes. Between December 2004 and May 2008 15 patients (mean age: 60.2 years) with choledochojejunal anastomosis underwent a total of 25 DBE-ERC procedures. Cannulation of the bile ducts was achieved in 22 / 25 procedures (84 %). Twenty-one therapeutic interventions, including stone removal, biliary duct dilation, stent placement and removal of previously placed stents were performed during 16 procedures in 8 patients. The mean total duration time of the procedures was 74.6 +/- 25.0 minutes. Postinterventional self-limiting fever occurred after 4 procedures in 3 patients with cholangitis. After therapeutic interventions all patients had a significant drop of bilirubin levels and all except one patient were free of complaints (follow-up 10.4 +/- 8.6 months). The DBE system permits diagnostic and therapeutic ERC in surgically modified anatomy, previously unavailable for endoluminal access. In our experience this procedure is safe and has a high success rate with a favourable patient outcome.

  15. Open abdominal surgical training differences experienced by integrated vascular and general surgery residents.

    PubMed

    Tanious, Adam; Wooster, Mathew; Jung, Andrew; Nelson, Peter R; Armstrong, Paul A; Shames, Murray L

    2017-10-01

    As the integrated vascular residency program reaches almost a decade of maturity, a common area of concern among trainees is the adequacy of open abdominal surgical training. It is our belief that although their overall exposure to open abdominal procedures has decreased, integrated vascular residents have an adequate and focused exposure to open aortic surgery during training. National operative case log data supplied by the Accreditation Council for Graduate Medical Education were compiled for both graduating integrated vascular surgery residents (IVSRs) and graduating categorical general surgery residents (GSRs) for the years 2012 to 2014. Mean total and open abdominal case numbers were compared between the IVSRs and GSRs, with more in-depth exploration into open abdominal procedures by organ system. Overall, the mean total 5-year case volume of IVSRs was 1168 compared with 980 for GSRs during the same time frame (P < .0001). IVSRs reported nearly double the number of surgeon-chief cases compared with GSRs (452 vs 239; P < .0001). GSRs reported more than double the number of open abdominal procedures compared with IVSRs (205 vs 83; P < .0001). Sixty-five percent of the open abdominal experience for IVSRs was focused on procedures involving the aorta and its branches, with an average of 54 open aortic cases recorded throughout their training. The largest single contributor to open surgical experience for a GSR was alimentary tract surgery, representing 57% of all open abdominal cases. GSRs completed an average of 116 open alimentary tract surgeries during their training. Open abdominal surgery represented an average of 7.1% of the total vascular case volume for the vascular residents, whereas open abdominal surgery represented 21% of a GSR's total surgical experience. IVSRs reported almost double the number of total cases during their training, with double chief-level cases. Sixty-five percent of open abdominal surgeries performed by IVSRs involved the aorta or its renovisceral branches. Whereas open abdominal surgery represented 7.1% of an IVSR's surgical training, GSRs had a far broader scope of open abdominal procedures, completing nearly double those of IVSRs. The differences in open abdominal procedures pertain to the differing diseases treated by GSRs and IVSRs. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  16. Complications of endoscopic dilation for esophageal stenosis after endoscopic submucosal dissection of superficial esophageal cancer.

    PubMed

    Kishida, Yoshihiro; Kakushima, Naomi; Kawata, Noboru; Tanaka, Masaki; Takizawa, Kohei; Imai, Kenichiro; Hotta, Kinichi; Matsubayashi, Hiroyuki; Ono, Hiroyuki

    2015-10-01

    Endoscopic dilation (ED) is used for the treatment of benign strictures caused by reflux esophagitis or anastomotic stenosis after esophagectomy. Esophageal stenosis is a major complication after endoscopic submucosal dissection (ESD) of large superficial esophageal cancer, but little is known regarding the incidence of complications of ED for stenosis caused by esophageal ESD. This was a retrospective study conducted at a single institution. From September 2002 to December 2012, a total of 1,337 ED procedures were performed for stenosis after esophageal ESD in 121 patients. The incidence of complications of ED and related clinical characteristics were analyzed. The incidence of bleeding was 0.8 % (1/121) per patient and 0.07 % (1/1,337) per procedure. The incidence of perforation was 4.1 % (5/121) per patient and 0.37 % (5/1,337) per procedure. Perforation occurred at a median of third time of ED procedures (range 2-9 procedures) and at a median of 18 days (range 8-29 days) after ESD. There were no significant characteristics correlated to perforation, such as location, circumferential extent, or diameter of mucosal defect after ESD. The total number of ED procedures was significantly larger among perforation cases (37, range 6-57) compared with those without perforation (7, range 1-70) (p = 0.01), and the treatment duration tended to be longer (190 vs. 69 days, respectively). The incidence of bleeding caused by ED for esophageal stenosis after ESD was very low. Relevant risk of perforation should be considered for patients requiring multiple ED procedures.

  17. A comparative study of serial and parallel aeroelastic computations of wings

    NASA Technical Reports Server (NTRS)

    Byun, Chansup; Guruswamy, Guru P.

    1994-01-01

    A procedure for computing the aeroelasticity of wings on parallel multiple-instruction, multiple-data (MIMD) computers is presented. In this procedure, fluids are modeled using Euler equations, and structures are modeled using modal or finite element equations. The procedure is designed in such a way that each discipline can be developed and maintained independently by using a domain decomposition approach. In the present parallel procedure, each computational domain is scalable. A parallel integration scheme is used to compute aeroelastic responses by solving fluid and structural equations concurrently. The computational efficiency issues of parallel integration of both fluid and structural equations are investigated in detail. This approach, which reduces the total computational time by a factor of almost 2, is demonstrated for a typical aeroelastic wing by using various numbers of processors on the Intel iPSC/860.

  18. Cumulative Incidence of a Subsequent Surgery After Stress Urinary Incontinence and Pelvic Organ Prolapse Procedure.

    PubMed

    Wu, Jennifer M; Dieter, Alexis A; Pate, Virginia; Jonsson Funk, Michele

    2017-06-01

    To assess the 5-year risk and timing of repeat stress urinary incontinence (SUI) and pelvic organ prolapse (POP) procedures. We conducted a retrospective cohort study using a nationwide database, the 2007-2014 MarketScan Commercial Claims and Encounters and Medicare Supplemental Databases (Truven Health Analytics), which contain deidentified health care claims data from approximately 150 employer-based insurance plans across the United States. We included women aged 18-84 years and used Current Procedural Terminology codes to identify surgeries for SUI and POP. We identified index procedures for SUI or POP after at least 3 years of continuous enrollment without a prior procedure. We defined three groups of women based on the index procedure: 1) SUI surgery only; 2) POP surgery only; and 3) Both SUI+POP surgery. We assessed the occurrence of a subsequent SUI or POP procedure over time for women younger than 65 years and 65 years or older with a median follow-up time of 2 years (interquartile range 1-4). We identified a total of 138,003 index procedures: SUI only n=48,196, POP only n=49,120, and both SUI+POP n=40,687. The overall cumulative incidence of a subsequent SUI or POP surgery within 5 years after any index procedure was 7.8% (95% confidence interval [CI] 7.6-8.1) for women younger than 65 years and 9.9% (95% CI 9.4-10.4) for women 65 years or older. The cumulative incidence was lower if the initial surgery was SUI only and higher if an initial POP procedure was performed, whether POP only or SUI+POP. The 5-year risk of undergoing a repeat SUI or POP surgery was less than 10% with higher risks for women 65 years or older and for those who underwent an initial POP surgery.

  19. Safety and efficacy of noncardiac surgical procedures in the management of patients with trisomy 13: A single institution-based detailed clinical observation.

    PubMed

    Shibuya, Soichi; Miyake, Yuichiro; Takamizawa, Shigeru; Nishi, Eriko; Yoshizawa, Katsumi; Hatata, Tomoko; Yoshizawa, Kazuki; Fujita, Kenya; Noguchi, Masahiko; Ohata, Jun; Hiroma, Takehiko; Nakamura, Tomohiko; Kosho, Tomoki

    2018-05-01

    Intensive treatment including surgery for patients with trisomy 13 (T13) remains controversial. This study aimed to evaluate the safety and efficacy of noncardiac surgical intervention for T13 patients. Medical records of patients with karyotypically confirmed T13 treated in the neonatal intensive care unit in Nagano Children's Hospital from January 2000 to October 2016 were retrospectively reviewed, and data from patients who underwent noncardiac surgery were analyzed. Of the 20 patients with T13, 15 (75%) underwent a total of 31 surgical procedures comprising 15 types, including tracheostomy in 10 patients and gastrostomy in 4. Operative time, anesthesia time, and amount of bleeding are described for the first time in a group of children with T13. All the procedures were completed safely with no anesthetic complications or surgery-related death. The overall rate of postoperative complications was 19.3%. Patients receiving tracheostomy had stable or improved respiratory condition. Six of them were discharged home and were alive at the time of this study. These results suggest at least short-term safety and efficacy of major noncardiac surgical procedures, and long-term efficacy of tracheostomy on survival or respiratory stabilization for home medical care of children with T13. Noncardiac surgical intervention is a reasonable choice for patients with T13. © 2018 Wiley Periodicals, Inc.

  20. Scandinavian Total Ankle Replacement: 15-Year Follow-up.

    PubMed

    Palanca, Ariel; Mann, Roger A; Mann, Jeffrey A; Haskell, Andrew

    2018-02-01

    Over the past decade, total ankle arthroplasty (TAA) has become a mainstay in the treatment of end-stage ankle arthritis. Currently in its fourth generation, the Scandanavian Total Ankle Replacement (STAR) is the only 3-piece mobile bearing ankle prosthesis available in the United States. Our current study reports implant survivorship at 15 years and patient outcomes for a subset of these survivors available for study. Eighty-four TAAs were performed between 1998 and 2000. Metal component survivorship at 15 years was calculated with a Kaplan-Meier curve. Twenty-four (29%) of 84 patients were available for participation with a minimum 15-year follow-up. Any radiographic changes were documented. All additional procedures and complications were recorded. Clinical findings, self-reported performance and pain evaluations, and AOFAS ankle/hindfoot scores were noted. Metal implant survival was 73% at 15 years. Of the 24 patients available for clinical evaluation, 18 of 24 patients (70.7%) had no change in prosthetic alignment from the immediate postoperative radiograph. Only 1 subtalar fusion was required for symptomatic adjacent joint arthritis. Three patients sustained a broken polyethylene component. AOFAS scores improved from an average of 39.6 points preoperatively, to an average of 71.6. More than half (52.4%) of patients with retained implants required an additional surgical procedure; 3 required 2 additional procedures. The average time to subsequent procedure was 10.2 years. Our small cohort demonstrated STAR ankles with retention at 9 years were highly likely to survive to 15 years, and patients continued to have significant improvement in pain relief and minimal decrease in function. At 15 years from TAA, metal survivorship was 73%. As with all ankle replacements, supplementary procedures were common. Level IV, case series.

  1. Ergonomics perspective for identifying and reducing internal operative flow disruption for laparoscopic urological surgery.

    PubMed

    Al-Hakim, Latif; Xiao, Jiaquan; Sengupta, Shomik

    2017-12-01

    The aim of this study is to examine operative flow disruption that occurs inside the surgical field, (internal operative flow disruption (OFD)), during urological laparoscopies, and to relate those events to external ergonomics environment in terms of monitor location, level of instruments' handles, and location of surgical team members. According to the our best knowledge, this is the first study of its kind. A combination of real and video-aided observational study was conducted in the operating rooms at hospitals in Australia and China. Brain storming sessions were first conducted to identify the main internal OFD events, and the observable reasons, potential external, and latent ergonomic factors were listed. A prospective observational study was then conducted. The observer's records and the related video records of internal surgical fields were analysed. Procedures were categorised into groups based on similarity in ergonomics environment. The mapping process revealed 39 types of internal OFD events resulted from six reasons. A total of 24 procedures were selected and arranged into two groups, each with twelve procedures. Group A was carried out under satisfactory ergonomics environment, while Group B was conducted under unsatisfactory ergonomics environment. A total of 1178 OFD events were detected delaying the total observed operative times (2966 min) by 220 min (7.43%). Average OFD/h in group A was less than 15, while in group B about 29 OFD/h. There are two main latent ergonomics factors affecting the surgeon's performance; non-physiological posture and long-period static posture. The delays and number of internal OFD were nearly doubled where procedures were conducted under unsatisfactory external ergonomics environment. Some events such as stopping operation and irrelevant conversations during long procedures may have a positive influence on the surgeon's performance.

  2. A time-accurate high-resolution TVD scheme for solving the Navier-Stokes equations

    NASA Technical Reports Server (NTRS)

    Kim, Hyun Dae; Liu, Nan-Suey

    1992-01-01

    A total variation diminishing (TVD) scheme has been developed and incorporated into an existing time-accurate high-resolution Navier-Stokes code. The accuracy and the robustness of the resulting solution procedure have been assessed by performing many calculations in four different areas: shock tube flows, regular shock reflection, supersonic boundary layer, and shock boundary layer interactions. These numerical results compare well with corresponding exact solutions or experimental data.

  3. 12 CFR 211.33 - Investments and extensions of credit.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... credit. (a) Amount of investments. In accordance with the procedures of § 211.34, an eligible investor... investor in an export trading company or companies may extend credit directly or indirectly to the export trading company or companies in a total amount that at no time exceeds 10 percent of the investor's...

  4. Navy Maintenance: The P-3 Aircraft Overhaul Program Can Be Improved.

    DTIC Science & Technology

    1987-06-01

    Air Sys- tems Command’s Naval Aviation Logistics Center, we obtained data on aircraft turnaround times, mobilization requirements, and aircraft over...480 561 637 P-3 Workload as a Percent of 23 22 25 27 Total FINDING Z: Aplicability of Procedural Changes To Other Aircraft. The GAO observed that the

  5. Evaluating the efficiency of a zakat institution over a period of time using data envelopment analysis

    NASA Astrophysics Data System (ADS)

    Krishnan, Anath Rau; Hamzah, Ahmad Aizuddin

    2017-08-01

    It is crucial for a zakat institution to evaluate and understand how efficiently they have operated in the past, thus ideal strategies could be developed for future improvement. However, evaluating the efficiency of a zakat institution is actually a challenging process as it involves the presence of multiple inputs or/and outputs. This paper proposes a step-by-step procedure comprising two data envelopment analysis models, namely dual Charnes-Cooper-Rhodes and slack-based model to quantitatively measure the overall efficiency of a zakat institution over a period of time. The applicability of the proposed procedure was demonstrated by evaluating the efficiency of Pusat Zakat Sabah, Malaysia from the year of 2007 up to 2015 by treating each year as a decision making unit. Two inputs (i.e. number of staff and number of branches) and two outputs (i.e. total collection and total distribution) were used to measure the overall efficiency achieved each year. The causes of inefficiency and strategy for future improvement were discussed based on the results.

  6. Visual distraction alone for the improvement of colonoscopy-related pain and satisfaction.

    PubMed

    Umezawa, Shotaro; Higurashi, Takuma; Uchiyama, Shiori; Sakai, Eiji; Ohkubo, Hidenori; Endo, Hiroki; Nonaka, Takashi; Nakajima, Atsushi

    2015-04-21

    To evaluate the effect of a relaxing visual distraction alone on patient pain, anxiety, and satisfaction during colonoscopy. This study was designed as an endoscopist-blinded randomized controlled trial with 60 consecutively enrolled patients who underwent elective colonoscopy at Yokohama City University Hospital, Japan. Patients were randomly assigned to two groups: group 1 watched a silent movie using a head-mounted display, while group 2 only wore the display. All of the colonoscopies were performed without sedation. We examined pain, anxiety, and the satisfaction of patients before and after the procedure using questionnaires that included the Visual Analog Scale. Patients were also asked whether they would be willing to use the same method for a repeat procedure. A total of 60 patients were allocated to two groups. Two patients assigned to group 1 and one patient assigned to group 2 were excluded after the randomization. Twenty-eight patients in group 1 and 29 patients in group 2 were entered into the final analysis. The groups were similar in terms of gender, age, history of prior colonoscopy, and pre-procedural anxiety score. The two groups were comparable in terms of the cecal insertion rate, the time to reach the cecum, the time needed for the total procedure, and vital signs. The median anxiety score during the colonoscopy did not differ significantly between the two groups (median scores, 20 vs 24). The median pain score during the procedure was lower in group 1, but the difference was not significant (median scores, 24.5 vs 42). The patients in group 1 reported significantly higher median post-procedural satisfaction levels, compared with the patients in group 2 (median scores, 89 vs 72, P = 0.04). Nearly three-quarters of the patients in group 1 wished to use the same method for repeat procedures, and the difference in rates between the two groups was statistically significant (75.0% vs 48.3%, P = 0.04). Patients with greater levels of anxiety before the procedure tended to feel a painful sensation. Among patients with a pre-procedural anxiety score of 50 or higher, the anxiety score during the procedure was significantly lower in the group that received the visual distraction (median scores, 20 vs 68, P = 0.05); the pain score during the colonoscopy was also lower (median scores, 23 vs 57, P = 0.04). No adverse effects arising from the visual distraction were recognized. Visual distraction alone improves satisfaction in patients undergoing colonoscopy and decreases anxiety and pain during the procedure among patients with a high pre-procedural anxiety score.

  7. Cognitive Task Analysis: Bringing Olympic Athlete Style Training to Surgical Education.

    PubMed

    Wingfield, Laura R; Kulendran, Myutan; Chow, Andre; Nehme, Jean; Purkayastha, Sanjay

    2015-08-01

    Surgical training is changing and evolving as time, pressure, and legislative demands continue to mount on trainee surgeons. A paradigm change in the focus of training has resulted in experts examining the cognitive steps needed to perform complex and often highly pressurized surgical procedures. To provide an overview of the collective evidence on cognitive task analysis (CTA) as a surgical training method, and determine if CTA improves a surgeon's performance as measured by technical and nontechnical skills assessment, including precision, accuracy, and operative errors. A systematic literature review was performed. PubMed, Cochrane, and reference lists were analyzed for appropriate inclusion. A total of 595 surgical participants were identified through the literature review and a total of 13 articles were included. Of these articles, 6 studies focused on general surgery, 2 focused on practical procedures relevant to surgery (central venous catheterization placement), 2 studies focused on head and neck surgical procedures (cricothyroidotomy and percutaneous tracheostomy placement), 2 studies highlighted vascular procedures (endovascular aortic aneurysm repair and carotid artery stenting), and 1 detailed endovascular repair (abdominal aorta and thoracic aorta). Overall, 92.3% of studies showed that CTA improves surgical outcome parameters, including time, precision, accuracy, and error reduction in both simulated and real-world environments. CTA has been shown to be a more effective training tool when compared with traditional methods of surgical training. There is a need for the introduction of CTA into surgical curriculums as this can improve surgical skill and ultimately create better patient outcomes. © The Author(s) 2014.

  8. Epistaxis: the factors involved in determining medicolegal liability.

    PubMed

    Khan, Mohemmed N; Blake, Danielle M; Vazquez, Alejandro; Setzen, Michael; Baredes, Soly; Eloy, Jean Anderson

    2014-01-01

    The purpose of this study was to examine litigation involving epistaxis and analyze factors that determine liability. Jury verdicts and settlements regarding cases involving epistaxis were gathered utilizing the Westlaw database. Factors involved in litigation gathered included demographics, defendant specialty, procedure, alleged cause of malpractice, outcome, monetary award, and other variables. A total of 26 cases were analyzed. The majority of cases (57.7%) were decided in favor of the plaintiff or settled out of court. Total awards amounted to $24,501,252. Average awards for cases decided in favor of the plaintiff were $2,260,893 and ranged from $499,845 to $9,022,643. Settlements averaged $1,084,375 and ranged from $300,000 to $3,800,000. Common causes of malpractice encountered included delay in diagnosis, complications from medical procedures, and failure to recognize complications in a timely manner. Contrary to previous reports analyzing malpractice for varying medical procedures and complications, litigation in epistaxis is more commonly resolved in favor of the plaintiff or resolved through out-of-court settlements. Substantial financial awards and therapeutic complications from blindness to death make epistaxis a candidate for litigation. Of importance from a medicolegal stand is the fact that 30.8% (8) of the patients involved in epistaxis litigation died, either from complications of therapy or from experiencing epistaxis as a complication of another procedure/pathology. Using necessary diagnostic imaging, ensuring proper management techniques, and recognizing complications in a timely manner can serve to limit legal liability and enhance patient safety. © 2013 ARS-AAOA, LLC.

  9. Impact of an electronic health record operating room management system in ophthalmology on documentation time, surgical volume, and staffing.

    PubMed

    Sanders, David S; Read-Brown, Sarah; Tu, Daniel C; Lambert, William E; Choi, Dongseok; Almario, Bella M; Yackel, Thomas R; Brown, Anna S; Chiang, Michael F

    2014-05-01

    Although electronic health record (EHR) systems have potential benefits, such as improved safety and quality of care, most ophthalmology practices in the United States have not adopted these systems. Concerns persist regarding potential negative impacts on clinical workflow. In particular, the impact of EHR operating room (OR) management systems on clinical efficiency in the ophthalmic surgery setting is unknown. To determine the impact of an EHR OR management system on intraoperative nursing documentation time, surgical volume, and staffing requirements. For documentation time and circulating nurses per procedure, a prospective cohort design was used between January 10, 2012, and January 10, 2013. For surgical volume and overall staffing requirements, a case series design was used between January 29, 2011, and January 28, 2013. This study involved ophthalmic OR nurses (n = 13) and surgeons (n = 25) at an academic medical center. Electronic health record OR management system implementation. (1) Documentation time (percentage of operating time documenting [POTD], absolute documentation time in minutes), (2) surgical volume (procedures/time), and (3) staffing requirements (full-time equivalents, circulating nurses/procedure). Outcomes were measured during a baseline period when paper documentation was used and during the early (first 3 months) and late (4-12 months) periods after EHR implementation. There was a worsening in total POTD in the early EHR period (83%) vs paper baseline (41%) (P < .001). This improved to baseline levels by the late EHR period (46%, P = .28), although POTD in the cataract group remained worse than at baseline (64%, P < .001). There was a worsening in absolute mean documentation time in the early EHR period (16.7 minutes) vs paper baseline (7.5 minutes) (P < .001). This improved in the late EHR period (9.2 minutes) but remained worse than in the paper baseline (P < .001). While cataract procedures required more circulating nurses in the early EHR (mean, 1.9 nurses/procedure) and late EHR (mean, 1.5 nurses/procedure) periods than in the paper baseline (mean, 1.0 nurses/procedure) (P < .001), overall staffing requirements and surgical volume were not significantly different between the periods. Electronic health record OR management system implementation was associated with worsening of intraoperative nursing documentation time especially in shorter procedures. However, it is possible to implement an EHR OR management system without serious negative impacts on surgical volume and staffing requirements.

  10. Improved Survival After the Ross Procedure Compared With Mechanical Aortic Valve Replacement.

    PubMed

    Buratto, Edward; Shi, William Y; Wynne, Rochelle; Poh, Chin L; Larobina, Marco; O'Keefe, Michael; Goldblatt, John; Tatoulis, James; Skillington, Peter D

    2018-03-27

    It is unclear whether the Ross procedure offers superior survival compared with mechanical aortic valve replacement (AVR). This study evaluated experience and compared long-term survival between the Ross procedure and mechanical AVR. Between 1992 and 2016, a total of 392 Ross procedures were performed. These were compared with 1,928 isolated mechanical AVRs performed during the same time period as identified using the University of Melbourne and Australia and New Zealand Society of Cardiac and Thoracic Surgeons' Cardiac Surgery Databases. Only patients between 18 and 65 years of age were included. Propensity-score matching was performed for risk adjustment. Ross procedure patients were younger, and had fewer cardiovascular risk factors. The Ross procedure was associated with longer cardiopulmonary bypass and aortic cross-clamp times. Thirty-day mortality was similar (Ross, 0.3%; mechanical, 0.8%; p = 0.5). Ross procedure patients experienced superior unadjusted long-term survival at 20 years (Ross, 95%; mechanical, 68%; p < 0.001). Multivariable analysis showed the Ross procedure to be associated with a reduced risk of late mortality (hazard ratio: 0.34; 95% confidence internal: 0.17 to 0.67; p < 0.001). Among 275 propensity-score matched pairs, Ross procedure patients had superior survival at 20 years (Ross, 94%; mechanical, 84%; p = 0.018). In this Australian, propensity-score matched study, the Ross procedure was associated with better long-term survival compared with mechanical AVR. In younger patients, with a long life expectancy, the Ross procedure should be considered in centers with sufficient expertise. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.

  11. Prevalence of Total Hip and Knee Replacement in the United States.

    PubMed

    Maradit Kremers, Hilal; Larson, Dirk R; Crowson, Cynthia S; Kremers, Walter K; Washington, Raynard E; Steiner, Claudia A; Jiranek, William A; Berry, Daniel J

    2015-09-02

    Descriptive epidemiology of total joint replacement procedures is limited to annual procedure volumes (incidence). The prevalence of the growing number of individuals living with a total hip or total knee replacement is currently unknown. Our objective was to estimate the prevalence of total hip and total knee replacement in the United States. Prevalence was estimated using the counting method by combining historical incidence data from the National Hospital Discharge Survey and the Healthcare Cost and Utilization Project (HCUP) State Inpatient Databases from 1969 to 2010 with general population census and mortality counts. We accounted for relative differences in mortality rates between those who have had total hip or knee replacement and the general population. The 2010 prevalence of total hip and total knee replacement in the total U.S. population was 0.83% and 1.52%, respectively. Prevalence was higher among women than among men and increased with age, reaching 5.26% for total hip replacement and 10.38% for total knee replacement at eighty years. These estimates corresponded to 2.5 million individuals (1.4 million women and 1.1 million men) with total hip replacement and 4.7 million individuals (3.0 million women and 1.7 million men) with total knee replacement in 2010. Secular trends indicated a substantial rise in prevalence over time and a shift to younger ages. Around 7 million Americans are living with a hip or knee replacement, and consequently, in most cases, are mobile, despite advanced arthritis. These numbers underscore the substantial public health impact of total hip and knee arthroplasties. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  12. Computations of total sediment discharge, Niobrara River near Cody, Nebraska

    USGS Publications Warehouse

    Colby, Bruce R.; Hembree, C.H.

    1955-01-01

    A natural chute in the Niobrara River near Cody, Nebr., constricts the flow of the river except at high stages to a narrow channel in which the turbulence is sufficient to suspend nearly the total sediment discharge. Because much of the flow originates in the sandhills area of Nebraska, the water discharge and sediment discharge are relatively uniform. Sediment discharges based on depth-integrated samples at a contracted section in the chute and on streamflow records at a recording gage about 1,900 feet upstream are available for the period from April 1948 to September 1953 but are not given directly as continuous records in this report. Sediment measurements have been made periodically near the gage and at other nearby relatively unconfined sections of the stream for comparison with measurements at the contracted section. Sediment discharge at these relatively unconfined sections was computed from formulas for comparison with measured sediment discharges at the contracted section. A form of the Du Boys formula gave computed tonnages of sediment that were unsatisfactory. Sediment discharges as computed from the Schoklitsch formula agreed well with measured sediment discharges that were low, but they were much too low at measured sediment discharges that were higher. The Straub formula gave computed discharges, presumably of bed material, that were several times larger than measured discharges of sediment coarser than 0.125 millimeter. All three of these formulas gave computed sediment discharges that increased with water discharges much less rapidly than the measured discharges of sediment coarser than 0.125 millimeter. The Einstein procedure when applied to a reach that included 10 defined cross sections gave much better agreement between computed sediment discharge and measured sediment discharge than did anyone of the three other formulas that were used. This procedure does not compute the discharge of sediment that is too small to be found in the stream bed in appreciable quantities. Hence, total sediment discharges were obtained by adding computed discharges of sediment larger than 0.125 millimeter to measured discharges of sediment smaller than 0.125 millimeter. The size distributions of the computed sediment discharge compared poorly with the size distributions of sediment discharge at the contracted section. Ten sediment discharges computed from the Einstein procedure as applied to a single section averaged several times the measured sediment discharge for the contracted section and gave size distributions that were unsatisfactory. The Einstein procedure was modified to compute total sediment discharge at an alluvial section from readily measurable field data. The modified procedure uses measurements of bed-material particle sizes, suspended-sediment concentrations and particle sizes from depth-integrated samples, streamflow, and water temperatures. Computations of total sediment discharge were made by using this modified procedure, some for the section at the gaging station and some for each of two other relatively unconfined sections. The size distributions of the computed and the measured sediment discharges agreed reasonably well. Major advantages of this modified procedure include applicability to a single section rather than to a reach of channel, use of measured velocity instead of water-surface slope, use of depth-integrated samples, and apparently fair accuracy for computing both total sediment discharge and approximate size distribution of the sediment. Because of these advantages this modified procedure is being further studied to increase its accuracy, to simplify the required computations, and to define its limitations. In the development of the modified procedure, some relationships concerning theories of sediment transport were reviewed and checked against field data. Vertical distributions of suspended sediment at relatively unconfined sections did not agree well with theoretical dist

  13. Reappraising the surgical approach on the perforated gastroduodenal ulcer: should gastric resection be abandoned?

    PubMed

    Kuwabara, Kazuaki; Matsuda, Shinya; Fushimi, Kiyohide; Ishikawa, Koichi B; Horiguchi, Hiromasa; Fujimori, Kenji

    2011-10-01

    Advancements in medical care for peptic ulcer disease (PUD) have reduced the need for invasive surgical procedures such as gastric resection (GR). Community-based PUD studies from a large sampling of PUD patients designed to analyze hospital resource use and outcomes after different surgical procedures have been rare. We aimed to exhaustively reappraise the risk factors and patient demographics that affect PUD patient recoveries after GR compared to those after simple closure (SC). We used a Japanese administrative database for 6 consecutive months each year between 2006 and 2010. The database included a total of 68,432 PUD patients; we analyzed 6,334 perforation cases and 3,148 cases of patients who underwent GR or SC. Study variables were demographics, comorbidities, characteristics of PUD, and operative day. Study outcomes that were analyzed included mortality, postoperative complications, ventilation administration, postoperative blood transfusions, length of stay, total charges, operating room (OR) time, and the postoperative fasting period (defined as the day of surgery to the day oral food intake was resumed.) To reduce selection bias in study procedures and to control the variation in hospital practice, a propensity score (PS) matching cohort analysis and a mixed linear regression model were used to assess the effects of GR on the outcomes. In 699 hospitals, 322 GRs and 2,826 SCs were observed. Younger age, duodenal ulcers, preexisting anemia and an operative day no more than 24hours were significant associated with the choice of SCs. No significant differences were observed in study outcomes after either GR or SC; more postoperative blood transfusions and longer OR times but shorter postoperative fasting periods were observed after GR. Longer OR times, ventilation and postoperative blood transfusion were significantly associated with mortality. Not GR but longer OR times use of ventilation and complications were the most significant indicators of increased resource use. There were no major significant differences in GR when compared to SC with regards to patient recoveries. Surgeons should obtain the skills and establish strategies to optimize either type of surgical procedure including minimizing OR time and establishing the best perioperative critical care. Peptic ulcer perforation; Simple closure; Gastric resection; Outcome; Resource use.

  14. Testing a potential alternative to traditional identification procedures: Reaction time-based concealed information test does not work for lineups with cooperative witnesses.

    PubMed

    Sauerland, Melanie; Wolfs, Andrea C F; Crans, Samantha; Verschuere, Bruno

    2017-11-27

    Direct eyewitness identification is widely used, but prone to error. We tested the validity of indirect eyewitness identification decisions using the reaction time-based concealed information test (CIT) for assessing cooperative eyewitnesses' face memory as an alternative to traditional lineup procedures. In a series of five experiments, a total of 401 mock eyewitnesses watched one of 11 different stimulus events that depicted a breach of law. Eyewitness identifications in the CIT were derived from longer reaction times as compared to well-matched foil faces not encountered before. Across the five experiments, the weighted mean effect size d was 0.14 (95% CI 0.08-0.19). The reaction time-based CIT seems unsuited for testing cooperative eyewitnesses' memory for faces. The careful matching of the faces required for a fair lineup or the lack of intent to deceive may have hampered the diagnosticity of the reaction time-based CIT.

  15. Percutaneous closure of patent foramen ovale without echocardiographic guidance.

    PubMed

    Jamshidi, Peiman; Wahl, Andreas; Windecker, Stephan; Schwerzmann, Markus; Seiler, Christian; Meier, Bernhard

    2007-01-01

    A percutaneous patent foramen ovale (PFO) closure procedure includes transesophageal or intracardiac echocardiographic guidance at many centers. We investigated the feasibility and complications of the PFO closure without echocardiography. A total of 420 consecutive patients (185 women and 235 men, mean age 51 +/- 12 years) underwent percutaneous PFO closure without echocardiographic guidance using 7 different devices. Of these, 106 patients (25%) had an associated atrial septal aneurysm. The implantation was successful in 418 patients (99%). There were 12 procedural complications (3%), including embolization of the device or of parts of it with successful percutaneous removal in 5 cases, pericardial tamponade requiring pericardiocentesis in 1 patient, air embolism with transient symptoms in 3 patients, and vascular access problems in 3 patients. In none of the cases, echocardiography had to be summoned during the case or its lack was associated with acute or subsequent problems. The fluoroscopy time and procedure time were 5.4 +/- 2.7 and 25 +/- 17 minutes, respectively. Transthoracic contrast echocardiography, 24 hours after device implantation, detected a residual shunt in 19% of the patients. Percutaneous PFO closure with fluoroscopic guidance only is feasible and has low complication rates, especially with Amplatzer PFO Occluders. The added time and cost of echocardiography during the procedure is not warranted.

  16. Endoscopically assisted tunnel approach for minimally invasive corticotomies: a preliminary report.

    PubMed

    Hernández-Alfaro, Federico; Guijarro-Martínez, Raquel

    2012-05-01

    The dental community has expressed low acceptance of traditional corticotomy techniques for corticotomy-facilitated orthodontics. These procedures are time consuming, entail substantial postoperative morbidity and periodontal risks, and are often perceived as highly invasive. A total of 114 interdental sites were treated in nine consecutive patients. Under local anesthesia, a tunnel approach requiring one to three vertical incisions per arch (depending on the targeted teeth) was used. Piezosurgical corticotomies and elective bone augmentation procedures were performed under endoscopic assistance. Postoperative cone-beam computerized tomography evaluation was used to confirm adequate corticotomy depth. Procedures were completed in a mean time of 26 minutes. Follow-up evaluations revealed no loss of tooth vitality, no changes in periodontal probing depth, good preservation of the papillae, and no gingival recession. No evidence of crestal bone height reduction or apical root resorption was detected. The tunnel approach minimizes soft-tissue debridement and permits effective cortical cuts. The combination of piezosurgery technique with endoscopic assistance provides a quick, reliable means to design and perform these corticotomies while maximizing root integrity preservation. Moreover, the sites needing bone augmentation are selected under direct vision. Compared to traditional corticotomies, this procedure has manifest advantages in surgical time, technical complexity, patient morbidity, and periodontium preservation.

  17. Modeling procedure and surgical times for current procedural terminology-anesthesia-surgeon combinations and evaluation in terms of case-duration prediction and operating room efficiency: a multicenter study.

    PubMed

    Stepaniak, Pieter S; Heij, Christiaan; Mannaerts, Guido H H; de Quelerij, Marcel; de Vries, Guus

    2009-10-01

    Gains in operating room (OR) scheduling may be obtained by using accurate statistical models to predict surgical and procedure times. The 3 main contributions of this article are the following: (i) the validation of Strum's results on the statistical distribution of case durations, including surgeon effects, using OR databases of 2 European hospitals, (ii) the use of expert prior expectations to predict durations of rarely observed cases, and (iii) the application of the proposed methods to predict case durations, with an analysis of the resulting increase in OR efficiency. We retrospectively reviewed all recorded surgical cases of 2 large European teaching hospitals from 2005 to 2008, involving 85,312 cases and 92,099 h in total. Surgical times tended to be skewed and bounded by some minimally required time. We compared the fit of the normal distribution with that of 2- and 3-parameter lognormal distributions for case durations of a range of Current Procedural Terminology (CPT)-anesthesia combinations, including possible surgeon effects. For cases with very few observations, we investigated whether supplementing the data information with surgeons' prior guesses helps to obtain better duration estimates. Finally, we used best fitting duration distributions to simulate the potential efficiency gains in OR scheduling. The 3-parameter lognormal distribution provides the best results for the case durations of CPT-anesthesia (surgeon) combinations, with an acceptable fit for almost 90% of the CPTs when segmented by the factor surgeon. The fit is best for surgical times and somewhat less for total procedure times. Surgeons' prior guesses are helpful for OR management to improve duration estimates of CPTs with very few (<10) observations. Compared with the standard way of case scheduling using the mean of the 3-parameter lognormal distribution for case scheduling reduces the mean overreserved OR time per case up to 11.9 (11.8-12.0) min (55.6%) and the mean underreserved OR time per case up to 16.7 (16.5-16.8) min (53.1%). When scheduling cases using the 4-parameter lognormal model the mean overutilized OR time is up to 20.0 (19.7-20.3) min per OR per day lower than for the standard method and 11.6 (11.3-12.0) min per OR per day lower as compared with the biased corrected mean. OR case scheduling can be improved by using the 3-parameter lognormal model with surgeon effects and by using surgeons' prior guesses for rarely observed CPTs. Using the 3-parameter lognormal model for case-duration prediction and scheduling significantly reduces both the prediction error and OR inefficiency.

  18. A comparison of case volumes among urologic surgeons identified on an industry-sponsored website to an all provider peer group.

    PubMed

    See, William A; Jacobson, Kenneth; Derus, Sue; Langenstroer, Peter

    2014-11-01

    Industry-sponsored websites for robotic surgery direct to surgeons listed as performing specific robotic surgical procedures. The purpose of this study was to compare average annual, surgeon-specific, case volumes for those procedures for which they were listed as performing on the commercial website with the volumes of all providers performing these same procedures across a defined geographic region. A list of providers within the state of Wisconsin cited as performing specific urologic procedures was obtained through the Intuitive Surgical website 〈http://www.davincisurgery.com/da-vinci-urology/〉. Surgeon-specific annual case volumes from 2009 to 2013 for these same cases were obtained for all Wisconsin providers through DataBay Resources (Warrendale, PA) based on International classification of diseases-9 codes. Procedural activity was rank ordered, and surgeons were placed in "volume deciles" derived from the total annual number of cases performed by all surgeons. The distribution of commercially listed surgeon volumes, both 5-year average and most recent year, was compared with the average and 2013 volumes of all surgeons performing a specific procedure. A total of 35 individual urologic surgeons listed as performing robotic surgery in Wisconsin were identified through a "search" using the Intuitive Surgical website. Specific procedure analysis returned 5, 12, 9, and 15 surgeon names for cystectomy, partial nephrectomy, radical nephrectomy, and prostatectomy, respectively. This compared with the total number of surgeons who had performed the listed procedure in Wisconsin at least 1 time during the prior 5 years of 123, 153, 242, and 165, respectively. When distributed by surgeon-volume deciles, surgeons listed on industry-sponsored sites varied widely in their respective volume decile. More than half of site-listed, procedure-specific surgeons fell below the fifth decile for surgeon volume. Data analysis based solely on 2013 case volumes had no effect on the number of website-listed surgeons whose volumes fell below the fifth decile. Surgeons listed on an industry-sponsored website demonstrate wide variation in the actual volume of specific procedures performed. The inferred endorsement of competence by commercial sites has the potential to mislead patients seeking surgical expertise. Providers should consider the ethical and legal implications of these commercial advertising that do not have volume or outcome data. Published by Elsevier Inc.

  19. Real-time fusion of coronary CT angiography with x-ray fluoroscopy during chronic total occlusion PCI.

    PubMed

    Ghoshhajra, Brian B; Takx, Richard A P; Stone, Luke L; Girard, Erin E; Brilakis, Emmanouil S; Lombardi, William L; Yeh, Robert W; Jaffer, Farouc A

    2017-06-01

    The purpose of this study was to demonstrate the feasibility of real-time fusion of coronary computed tomography angiography (CTA) centreline and arterial wall calcification with x-ray fluoroscopy during chronic total occlusion (CTO) percutaneous coronary intervention (PCI). Patients undergoing CTO PCI were prospectively enrolled. Pre-procedural CT scans were integrated with conventional coronary fluoroscopy using prototype software. We enrolled 24 patients who underwent CTO PCI using the prototype CT fusion software, and 24 consecutive CTO PCI patients without CT guidance served as a control group. Mean age was 66 ± 11 years, and 43/48 patients were men. Real-time CTA fusion during CTO PCI provided additional information regarding coronary arterial calcification and tortuosity that generated new insights into antegrade wiring, antegrade dissection/reentry, and retrograde wiring during CTO PCI. Overall CTO success rates and procedural outcomes remained similar between the two groups, despite a trend toward higher complexity in the fusion CTA group. This study demonstrates that real-time automated co-registration of coronary CTA centreline and calcification onto live fluoroscopic images is feasible and provides new insights into CTO PCI, and in particular, antegrade dissection reentry-based CTO PCI. • Real-time semi-automated fusion of CTA/fluoroscopy is feasible during CTO PCI. • CTA fusion data can be toggled on/off as desired during CTO PCI • Real-time CT calcium and centreline overlay could benefit antegrade dissection/reentry-based CTO PCI.

  20. [Endovascular treatment of acute iliofemoral deep venous thrombosis - our results with catheter-directed thrombolysis and AngioJet].

    PubMed

    Berencsi, Anikó; Dósa, Edit; Nemes, Balázs; Hüttl, Kálmán; Legeza, Péter; Oláh, Zoltán; Kristóf, Vera; Acsády, György; Sótonyi, Péter

    2017-03-01

    Most of the patients with iliofemoral thrombosis treated with anticoagulants only are affected with postthrombotic syndrome (PTS) that worsens the patients' quality of life. In the acute phase of proximal deep venous thrombosis (DVT) catheter-directed (CDT) and pharmacomechanical thrombolysis may be a reasonable alternative therapeutic method. Our aim was to summarize our results using these methods. Since 2009 twenty-four patients with iliofemoral DVT were treated with these endovascular procedures and with stenting at our Institution. The median age of the patients was 35.83 ± 15.9 years, the female: male ratio was approximately 2:1. The mean time between the onset of the symptoms and the procedures was eleven days. CDT alone was performed in 8 patients, thrombus aspiration in addition to CDT using AngioJet device in 16 patients; in 19 cases the procedure was completed with venous stenting. During the follow-up we performed US examinations and estimated the severity of PTS by Villalta-scale. The total recanalization-rate was more than 50%, which even improved during the follow-up. The total lysis time and the amount of used recombinant tissue plasminogen activator decreased significantly by applying the AngioJet. We did not find any severe PTS among our patients during the follow-up visits. Our data suggests that these methods can be used efficiently and safely in the treatment of acute iliofemoral DVT.

  1. Safety of endoscopic removal of self-expandable stents after treatment of benign esophageal diseases.

    PubMed

    van Halsema, Emo E; Wong Kee Song, Louis M; Baron, Todd H; Siersema, Peter D; Vleggaar, Frank P; Ginsberg, Gregory G; Shah, Pari M; Fleischer, David E; Ratuapli, Shiva K; Fockens, Paul; Dijkgraaf, Marcel G W; Rando, Giacomo; Repici, Alessandro; van Hooft, Jeanin E

    2013-01-01

    Temporary placement of self-expandable stents has been increasingly used for the management of benign esophageal diseases. To evaluate the safety of endoscopic removal of esophageal self-expandable stents placed for the treatment of benign esophageal diseases. Multicenter retrospective study. Six tertiary care centers in the United States and Europe. A total of 214 patients with benign esophageal diseases undergoing endoscopic stent removal. Endoscopic stent removal. Endoscopic techniques for stent removal, time to stent removal, and adverse events related to stent removal. A total of 214 patients underwent a total of 329 stent extractions. Stents were mainly placed for refractory strictures (49.2%) and fistulae (49.8%). Of the removed stents, 52% were fully covered self-expandable metal stents (FCSEMSs), 28.6% were partially covered self-expandable metal stents (PCSEMSs), and 19.5% were self-expandable plastic stents. A total of 35 (10.6%) procedure-related adverse events were reported, including 7 (2.1%) major adverse events. Multivariate analysis revealed that use of PCSEMSs (P < .001) was a risk factor for adverse events during stent removal. Favorable factors for successful stent removal were FCSEMSs (P ≤ .012) and stent migration (P = .010). No significant associations were found for stent indwelling time (P = .145) and stent embedding (P = .194). Retrospective analysis, only tertiary care centers. With an acceptable major adverse event rate of 2.1%, esophageal stent removal in the setting of benign disease was found to be a safe and feasible procedure. FCSEMSs were more successfully removed than self-expandable plastic stents and PCSEMSs. Adverse events caused by stent removal were not time dependent. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  2. What's Gender Got to Do With It: Difference in the Proportion of Traditionally Female Cases Performed by General Urologists of Each Gender.

    PubMed

    Rotker, Katherine; Iosifescu, Sarah; Baird, Grayson; Thavaseelan, Simone; Hwang, Kathleen

    2018-06-01

    To examine surgical case volume characteristics in certifying urologists to evaluate practice patterns, given the long-standing understanding but unproven hypothesis that non-fellowship trained female general urologists perform more urogynecologic procedures compared with their equally trained male counterparts. Case log data from certifying and recertifying urologists from 2000 to 2015 were obtained from the American Board of Urology. Thirty-seven Current Procedural Terminology (CPT) codes were chosen to represent traditionally urogynecologic cases. Logistic regression analysis models were used to determine the percentage of total CPT codes logged during the certification period made up by traditionally urogynecologic cases. Male and female non-fellowship trained, self-described general urologists were compared. The case logs of 4032 non-fellowship trained general urologists were reviewed from 2000 to 2015, 297 of whom were female and 3735 of whom were male. Urogynecologic cases made up 1.27% of the total CPT codes logged by the women and 0.59% of those codes logged by the men (P <.001), an increase of 2.2 times (P <.001). This statistically significant difference persisted regardless of certification period, geographic location, population density, or full-time vs part-time employment. Traditional urogynecologic cases represented a significantly greater percentage of the total cases logged by non-fellowship trained female general urologists compared with their non-fellowship trained, generalist male colleagues. The percentage of total cases performed by both is very small. However, it supports a belief that patient populations differ for male and female general urologists, which may impact training or career choices. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Impact of the European Working Time Directive (EWTD) on the operative experience of surgery residents.

    PubMed

    Hopmans, Cornelis J; den Hoed, Pieter T; van der Laan, Lijckle; van der Harst, Erwin; van der Elst, Maarten; Mannaerts, Guido H H; Dawson, Imro; Timman, Reinier; Wijnhoven, Bas P L; IJzermans, Jan N M

    2015-04-01

    In Europe and the United States, work hour restrictions are considered to be particularly burdensome for residents in surgery specialties. The aim of this study was to examine whether reduction of the work week to 48 hours resulting from the implementation of the European Working Time Directive has affected the operative experience of surgery residents. This study was conducted in a general surgery training region in the Netherlands, consisting of 1 university hospital and 6 district training hospitals. Operating records summarizing the surgical procedures performed as "primary surgeon" in the operating theater for different grades of surgeons were retrospectively analyzed for the period 2005-2012 by the use of linear regression models. Operative procedures performed by residents were considered the main outcome measure. In total, 235,357 operative procedures were performed, including 47,458 (20.2%) in the university hospital and 187,899 (79.8%) in the district training hospitals (n = 5). For residents in the university hospital, the mean number of operative procedures performed per 1.0 full-time equivalent increased from 128 operations in 2005 to 204 operations in 2012 (P = .001), whereas for residents in district training hospitals, no substantial differences were found over time. The mean (±SD) operative caseload of 64 residents who completed the 6-year training program between 2005 and 2012 was 1,391 ± 226 (range, 768-1856). A comparison of the operative caseload according to year of board-certification showed no difference. Implementation of the European Working Time Directive has not affected adversely the number of surgical procedures performed by residents within a general surgical training region in the Netherlands. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Computed-tomography modeled polyether ether ketone (PEEK) implants in revision cranioplasty.

    PubMed

    O'Reilly, Eamon B; Barnett, Sam; Madden, Christopher; Welch, Babu; Mickey, Bruce; Rozen, Shai

    2015-03-01

    Traditional cranioplasty methods focus on pre-operative or intraoperative hand molding. Recently, CT-guided polyether ether ketone (PEEK) plate reconstruction enables precise, time-saving reconstruction. This case series aims to show a single institution experience with use of PEEK cranioplasty as an effective, safe, precise, reusable, and time-saving cranioplasty technique in large, complex cranial defects. We performed a 6-year retrospective review of cranioplasty procedures performed at our affiliated hospitals using PEEK implants. A total of nineteen patients underwent twenty-two cranioplasty procedures. Pre-operative, intra-operative, and post-operative data was collected. Nineteen patients underwent twenty-two procedures. Time interval from injury to loss of primary cranioplasty averaged 57.7 months (0-336 mo); 4.0 months (n=10, range 0-19) in cases of trauma. Time interval from primary cranioplasty loss to PEEK cranioplasty was 11.8 months for infection (n=11, range 6-25 mo), 12.2 months for trauma (n=5, range 2-27 mo), and 0.3 months for cosmetic or functional reconstructions (n=3, range 0-1). Similar surgical techniques were used in all patients. Drains were placed in 11/22 procedures. Varying techniques were used in skin closure, including adjacent tissue transfer (4/22) and free tissue transfer (1/22). The PEEK plate required modification in four procedures. Three patients had reoperation following PEEK plate reconstruction. Cranioplasty utilizing CT-guided PEEK plate allows easy inset, anatomic accuracy, mirror image aesthetics, simplification of complex 3D defects, and potential time savings. Additionally, it's easily manipulated in the operating room, and can be easily re-utilized in cases of intraoperative course changes or infection. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  5. Pulmonary Vein Isolation with the Cryoballoon Technique: Feasibility, Procedural Outcomes, and Adoption in the Real World: Data from One Shot Technologies TO Pulmonary Vein Isolation (1STOP) Project.

    PubMed

    Padeletti, Luigi; Curnis, Antonio; Tondo, Claudio; Lunati, Maurizio; Porcellini, Stefano; Verlato, Roberto; Sciarra, Luigi; Senatore, Gaetano; Catanzariti, Domenico; Leoni, Loira; Landolina, Maurizio; Delise, Pietro; Iacopino, Saverio; Pieragnoli, Paolo; Arena, Giuseppe

    2017-01-01

    Catheter ablation (CA) is recommended for patients with drug refractory symptomatic atrial fibrillation (AF). "One Shot" catheters have been introduced to simplify CA and cryoballoon ablation (CBA) is spreading rapidly. Few real-world data are available on standard clinical practice, mainly from single-center experience. We aimed to evaluate clinical settings, demographics, and acute procedural outcomes in a large cohort of patients treated with CBA. A total of 903 patients (73% male, mean age 59 ± 11) underwent pulmonary vein CBA. Correlations between the patient's inclusion time and clinical characteristics, procedure duration, acute success rate, and intraprocedural complications were evaluated. Seventy-seven percent of patients were affected by paroxysmal AF and 23% by persistent AF. Overall, acute success rate was 97.9% and periprocedural complications were observed in 35 (3.9%) patients, 13 (1.4%) of which were classified as major complications. With respect to the patient's inclusion time analysis, an increase in treatment of persistent AF was observed, a significant decrease in CBA times (procedure, ablation, and fluoroscopy: 136.0 ± 46.5 minutes, 28.8 ± 19.6 minutes, and 34.3 ± 15.4 minutes, respectively) was observed, with comparable acute success rate and intraprocedural complications over time. The rate of major complications was extremely low (1.4%); no death, atrioesophageal fistula, stroke, or other major periinterventional or late complications occurred. This series represents the largest experience of CBA in the treatment of AF that also describes the adoption curve of this relatively recent technology. CBA showed an excellent safety profile when performed in a large real-world clinical setting, with satisfactory acute success rate and, on average, short procedural times. clinicaltrials.gov (NCT01007474). © 2016 Wiley Periodicals, Inc.

  6. Online doctor reviews: do they track surgeon volume, a proxy for quality of care?

    PubMed

    Segal, Jeffrey; Sacopulos, Michael; Sheets, Virgil; Thurston, Irish; Brooks, Kendra; Puccia, Ryan

    2012-04-10

    Increasingly, consumers are accessing the Internet seeking health information. Consumers are also using online doctor review websites to help select their physician. Such websites tally numerical ratings and comments from past patients. To our knowledge, no study has previously analyzed whether doctors with positive online reputations on doctor review websites actually deliver higher quality of care typically associated with better clinical outcomes and better safety records. For a number of procedures, surgeons who perform more procedures have better clinical outcomes and safety records than those who perform fewer procedures. Our objective was to determine if surgeon volume, as a proxy for clinical outcomes and patient safety, correlates with online reputation. We investigated the numerical ratings and comments on 9 online review websites for high- and low-volume surgeons for three procedures: lumbar surgery, total knee replacement, and bariatric surgery. High-volume surgeons were randomly selected from the group within the highest quartile of claims submitted for reimbursement using the procedures' relevant current procedural terminology (CPT) codes. Low-volume surgeons were randomly selected from the lowest quartile of submitted claims for the procedures' relevant CPT codes. Claims were collated within the Normative Health Information Database, covering multiple payers for more than 25 million insured patients. Numerical ratings were found for the majority of physicians in our sample (547/600, 91.2%) and comments were found for 385/600 (64.2%) of the physicians. We found that high-volume (HV) surgeons could be differentiated from low-volume (LV) surgeons independently by analyzing: (1) the total number of numerical ratings per website (HV: mean = 5.85; LV: mean = 4.87, P<.001); (2) the total number of text comments per website (HV: mean = 2.74; LV: mean = 2.30, P=.05); (3) the proportion of glowing praise/total comments about quality of care (HV: mean = 0.64; LV: mean = 0.51, P=.002); and (4) the proportion of scathing criticism/total comments about quality of care (HV: mean = 0.14; LV: mean = 0.23, P= .005). Even when these features were combined, the effect size, although significant, was still weak. The results revealed that one could accurately identify a physician's patient volume via discriminant and classification analysis 61.6% of the time. We also found that high-volume surgeons could not be differentiated from low-volume surgeons by analyzing (1) standardized z score numerical ratings (HV: mean = 0.07; LV: mean = 0, P=.27); (2) proportion of glowing praise/total comments about customer service (HV: mean = 0.24; LV: mean = 0.22, P=.52); and (3) proportion of scathing criticism/total comments about customer service (HV: mean = 0.19; LV: mean = 0.21, P=.48). Online review websites provide a rich source of data that may be able to track quality of care, although the effect size is weak and not consistent for all review website metrics.

  7. Gas Chromatographic Presumptive Test for Coliform Bacteria in Water

    PubMed Central

    Newman, Judith S.; O'Brien, R. T.

    1975-01-01

    A gas chromatographic procedure which shows promise as a presumptive test for coliform bacteria in water is described. Total coliform bacteria concentrations were determined from the incubation times at 37 C required for ethanol to be produced. Fecal coliform densities were determined in a similar manner at 44.5 C. The culture medium was filter sterilized M-9 salts supplemented with 1% lactose, 0.1% Casamino Acids, and 0.1% yeast extract. Best results were obtained when the initial total coliform concentrations were 5 per ml or higher and when fecal coliform concentrations were 50 per ml or higher. Minimum detection times at these concentrations were 9 and 12 h, respectively. PMID:1103731

  8. A robust and non-obtrusive automatic event tracking system for operating room management to improve patient care.

    PubMed

    Huang, Albert Y; Joerger, Guillaume; Salmon, Remi; Dunkin, Brian; Sherman, Vadim; Bass, Barbara L; Garbey, Marc

    2016-08-01

    Optimization of OR management is a complex problem as each OR has different procedures throughout the day inevitably resulting in scheduling delays, variations in time durations and overall suboptimal performance. There exists a need for a system that automatically tracks procedural progress in real time in the OR. This would allow for efficient monitoring of operating room states and target sources of inefficiency and points of improvement. We placed three wireless sensors (floor-mounted pressure sensor, ventilator-mounted bellows motion sensor and ambient light detector, and a general room motion detector) in two ORs at our institution and tracked cases 24 h a day for over 4 months. We collected data on 238 total cases (107 laparoscopic cases). A total of 176 turnover times were also captured, and we found that the average turnover time between cases was 35 min while the institutional goal was 30 min. Deeper examination showed that 38 % of laparoscopic cases had some aspect of suboptimal activity with the time between extubation and patient exiting the OR being the biggest contributor (16 %). Our automated system allows for robust, wireless real-time OR monitoring as well as data collection and retrospective data analyses. We plan to continue expanding our system and to project the data in real time for all OR personnel to see. At the same time, we plan on adding key pieces of technology such as RFID and other radio-frequency systems to track patients and physicians to further increase efficiency and patient safety.

  9. A novel stereotactic frame for real PET-guided biopsies: A preclinical proof-of-concept.

    PubMed

    Cortes-Rodicio, J; Sanchez-Merino, G; Garcia-Fidalgo, M A; Tobalina-Larrea, I

    2017-09-01

    To design, build and test a stereotactic device that allows PET image-guided biopsies to be performed. An initial prototype consisting of four main pieces, one of which contains radioactive markers to make it visible in the PET images, was built using a 3D printer. Once the device is mounted, a spherical coordinate system is built with the entrance needle point in the skin as the origin of coordinates. Two in-house software programs, namely getCoord.ijm, which obtains the spherical coordinates of the tumour tissue to be biopsied, and getNeedle.ijm, which virtualizes the inner needle tip once the puncture has taken place, were written. This prototype was tested on an FDG-doped phantom to characterize both the accuracy of the system and the procedure time. Up to 11 complete biopsy procedures were conducted. The mean total procedure time was less than 20min, which is less than the procedure time of conventional standard CT-guided biopsies. The overall accuracy of the system was found to be 5.0±1.3mm, which outperforms the criterion used in routine clinical practice when targeting tumours with a diameter of 10mm. A stereotactic frame to conduct real PET image-guided biopsies has been designed and built. A proof-of-concept was performed to characterize the system. The procedure time and accuracy of the system were found to meet the current needs of physicians performing biopsies. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  10. Does a patent foramen ovale matter when using a remote-controlled magnetic system for pulmonary vein isolation?

    PubMed

    Gate-Martinet, Alexie; Da Costa, Antoine; Romeyer-Bouchard, Cécile; Bisch, Laurence; Levallois, Marie; Isaaz, Karl

    2014-02-01

    Pulmonary vein isolation (PVI) takes longer when using a patent foramen ovale (PFO) compared with a transseptal puncture in paroxysmal atrial fibrillation (AF) with manual catheter ablation. To our knowledge, no data exist concerning the impact of a PFO on AF ablation procedure variables when using a remote magnetic navigation (RMN) system. To assess the impact of a PFO when using an RMN system in patients requiring AF ablation. Between December 2011 and December 2012, catheter ablation was performed remotely using the CARTO(®) 3 system in 167 consecutive patients who underwent PVI for symptomatic drug-refractory AF. The radiofrequency generator was set to a fixed power ≤ 35 W. The primary endpoint was wide-area circumferential PVI confirmed by spiral catheter recording during ablation for all patients and including additional lesion lines (left atrial roof) or complex fractionated atrial electrograms for persistent AF. Secondary endpoints included procedural data. Mean age 58±10 years; 18% women; 107 (64%) patients with symptomatic paroxysmal AF; 60 (36%) with persistent AF; CHA2DS2-VASc score 1.2 ± 1. The PFO presence was evidenced in 49/167 (29.3%) patients during the procedure but in only 26/167 (16%) by transoesophageal echocardiography. Median procedure time 2.5 ± 1 hours; median total X-ray exposure time 14 ± 7 minutes; transseptal puncture and catheter positioning time 7.5 ± 5 minutes; left atrium electroanatomical reconstruction time 3 ± 2.3 minutes; catheter ablation time 3 ± 3 minutes. No procedure time or X-ray exposure differences were observed between patients with or without a PFO during magnetic navigation catheter ablation. X-ray exposure time was significantly reduced using a PFO compared with double transseptal puncture access. A PFO does not affect magnetic navigation during AF ablation; procedure times and X-ray exposure were similar. Septal catheter probing is mandatory to limit X-ray exposure and prevent potential complications. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  11. Quality-Assurance Data for Routine Water Analyses by the U.S. Geological Survey Laboratory in Troy, New York--July 1999 through June 2001

    USGS Publications Warehouse

    Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.

    2006-01-01

    The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's LabMaster data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality-control samples analyzed from July 1999 through June 2001. Results for the quality-control samples for 18 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, total aluminum, calcium, chloride and nitrate (ion chromatography and colormetric method) and sulfate. The total aluminum and dissolved organic carbon procedures were biased throughout the analysis period for the high-concentration sample, but were within control limits. The calcium and specific conductance procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The magnesium procedure was biased for the high-concentration and low concentration samples, but was within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 14 of 15 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for dissolved organic carbon. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 17 of the 18 analytes. At least 90 percent of the samples met data-quality objectives for all analytes except ammonium (81 percent of samples met objectives), chloride (75 percent of samples met objectives), and sodium (86 percent of samples met objectives). Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality over the time period, with most ratings for each sample in the good to excellent range. The P-sample (low-ionic-strength constituents) analysis had one satisfactory rating for the specific conductance procedure in one study. The T-sample (trace constituents) analysis had one satisfactory rating for the aluminum procedure in one study and one unsatisfactory rating for the sodium procedure in another. The remainder of the samples had good or excellent ratings for each study. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 89 percent of the samples met data-quality objectives for 10 of the 14 analytes; the exceptions were ammonium, total aluminum, dissolved organic carbon, and sodium. Results indicate a positive bias for the ammonium procedure in all studies. Data-quality objectives were not met in 50 percent of samples analyzed for total aluminum, 38 percent of samples analyzed for dissolved organic carbon, and 27 percent of samples analyzed for sodium. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 91 percent of the samples analyzed for calcium, chloride, fluoride, magnesium, pH, potassium, and sulfate. Data-quality objectives were met by 75 percent of the samples analyzed for sodium and 58 percent of the samples analyzed for specific conductance.

  12. Virtual reality, ultrasound-guided liver biopsy simulator: development and performance discrimination.

    PubMed

    Johnson, S J; Hunt, C M; Woolnough, H M; Crawshaw, M; Kilkenny, C; Gould, D A; England, A; Sinha, A; Villard, P F

    2012-05-01

    The aim of this article was to identify and prospectively investigate simulated ultrasound-guided targeted liver biopsy performance metrics as differentiators between levels of expertise in interventional radiology. Task analysis produced detailed procedural step documentation allowing identification of critical procedure steps and performance metrics for use in a virtual reality ultrasound-guided targeted liver biopsy procedure. Consultant (n=14; male=11, female=3) and trainee (n=26; male=19, female=7) scores on the performance metrics were compared. Ethical approval was granted by the Liverpool Research Ethics Committee (UK). Independent t-tests and analysis of variance (ANOVA) investigated differences between groups. Independent t-tests revealed significant differences between trainees and consultants on three performance metrics: targeting, p=0.018, t=-2.487 (-2.040 to -0.207); probe usage time, p = 0.040, t=2.132 (11.064 to 427.983); mean needle length in beam, p=0.029, t=-2.272 (-0.028 to -0.002). ANOVA reported significant differences across years of experience (0-1, 1-2, 3+ years) on seven performance metrics: no-go area touched, p=0.012; targeting, p=0.025; length of session, p=0.024; probe usage time, p=0.025; total needle distance moved, p=0.038; number of skin contacts, p<0.001; total time in no-go area, p=0.008. More experienced participants consistently received better performance scores on all 19 performance metrics. It is possible to measure and monitor performance using simulation, with performance metrics providing feedback on skill level and differentiating levels of expertise. However, a transfer of training study is required.

  13. Simplified methods for computing total sediment discharge with the modified Einstein procedure

    USGS Publications Warehouse

    Colby, Bruce R.; Hubbell, David Wellington

    1961-01-01

    A procedure was presented in 1950 by H. A. Einstein for computing the total discharge of sediment particles of sizes that are in appreciable quantities in the stream bed. This procedure was modified by the U.S. Geological Survey and adapted to computing the total sediment discharge of a stream on the basis of samples of bed sediment, depth-integrated samples of suspended sediment, streamflow measurements, and water temperature. This paper gives simplified methods for computing total sediment discharge by the modified Einstein procedure. Each of four homographs appreciably simplifies a major step in the computations. Within the stated limitations, use of the homographs introduces much less error than is present in either the basic data or the theories on which the computations of total sediment discharge are based. The results are nearly as accurate mathematically as those that could be obtained from the longer and more complex arithmetic and algebraic computations of the Einstein procedure.

  14. Pediatric procedural sedation with ketamine: time to discharge after intramuscular versus intravenous administration.

    PubMed

    Ramaswamy, Preeti; Babl, Franz E; Deasy, Conor; Sharwood, Lisa N

    2009-02-01

    Ketamine is an attractive agent for pediatric procedural sedation. There are limited data on time to discharge comparing intramuscular (IM) vs. intravenous (IV) ketamine. The authors set out to determine whether IM or IV ketamine leads to quicker discharge from the emergency department (ED) and how side effect profiles compare. All patients who had received ketamine IM or IV at a tertiary children's hospital ED during the 3-year study period (2004-2007) were identified. Prospective sedation registry data, retrospective medical records, and administrative data were reviewed for drug dosages, use of additional agents, time of drug administration to discharge, total ED time (triage to discharge), and adverse events. A subgroup analysis for patients requiring five or fewer sutures (short suture group) was performed. A total of 229 patients were enrolled (60% male) with median age of 2.8 years (IQR =1.8-4.3 years) and median weight of 15.7 kg (range = 8.7-74 kg). Ketamine was most frequently employed for laceration repair (80%) and foreign body removal (9%). Overall, 48% received ketamine IM and 52% received it IV. In the short-suture subgroup, 52% received ketamine IM, while 48% received it IV. Multivariate linear regression analysis determined time from drug administration to patient discharge as 21 minutes shorter for IV compared with IM administration, adjusted for age and number of additional doses (R(2) = -0.35; 95% CI = -0.5 to -0.19; p < 0.001). Total time in the ED (triage to discharge) comparing IV versus IM administration, adjusting for age and gender and number of additional doses, was not significantly different (p = 0.16). In the short-suture subgroup, time to discharge from administration was also shorter in the IV ketamine group (R(2) = -0.454; 95%CI = -0.66 to -0.25; p < 0.001) but similar for total time in ED (p = 0.16). Overall, adverse events occurred in 35% (95% CI = 27% to 45%) of the IM group and 20% (95% CI = 13% to 28%) of the IV group (p = 0.01). Only one patient required brief bag-mask ventilation. In this institution, time from drug injection to discharge was shorter in the IV compared to IM ketamine group, both overall and for the short-suture group. However, time from triage to discharge was similar.

  15. Can We Improve Workflows in the OR? A Comparison of Quality Perceptions and Preoperative Efficiency across Institutions in Spine Surgery.

    PubMed

    Wasterlain, Amy S; Tran, Andrew A; Tang, Chad; Campbell, David R; Braun, Hillary J; Scuderi, Yasmeen A; Scuderi, Gaetano J

    2015-03-01

    Cost containment and surgical inefficiencies are major concerns for hospitals in this era of declining resources. The primary aim of this investigation was to understand subjective perceptions of perioperative spine surgical quality across three practice settings and to identify potential factors contributing to these perceptions. Subsequently, we objectively evaluated factors that influence the duration of time in which the patient is in the operating room (OR) prior to the surgical incision and assessed the influence of fluoroscopy technician expertise on radiation dose and imaging efficiency. One hundred and eight medical device representatives with at least 1 year of OR experience were surveyed at a national conference. Three distinct healthcare facilities were identified: university, small volume, and large volume private hospitals. Respondents rated facilities on a five-point scale for staff quality; size and consistency of surgical teams; and overall likelihood of recommending the facility. Separately, 140 posterior lumbar procedures from two institutions were retrospectively reviewed. Two time periods were quantified for each surgical case: patient arrival in the OR to induction of anesthesia (T1) and induction to surgical incision (T2). T1 and T2 were compared between university and large private hospital settings using t tests and multivariate analysis. For 44 separate lumbar spine surgical procedures, practice setting, patient BMI, number of vertebral levels requiring imaging, number of localizing fluoroscopy images taken, total fluoroscopy time, total radiation dose, fluoroscopy machine, and whether the fluoroscopist could correctly state his or her role, which was to obtain a lateral lumbar localizing image, were recorded. T-tests were used to compare cases in which the fluoroscopist could and could not correctly state the task. Survey ratings for surgeons were not significantly different across university, large private, and small private hospitals. Fewer circulating nurses were rated as excellent or good in university versus private hospitals (p < 0.001). Small volume private hospital surgical teams were more likely to have worked together before than university teams (p < 0.05), and university teams were larger (p < 0.05). Respondents were more likely to recommend a university or large private hospital for complex instrumentation cases (p < 0.001). On objective measures, university patients were older, less obese, and had higher mean ASA scores (2.5 versus 2.2, p < 0.001). Compared to the university setting, private hospital cases had significantly shorter Time 1 (8 versus 37 min, p < 0.001) and Time 2 (23 versus 30 min, p < 0.001), even after adjusting for ASA score, BMI, and age. Cases in which the fluoroscopist knew the imaging purpose were associated with significantly fewer images (mean 1.8 versus 3.4 images, p < 0.0001) and shorter total exposure times (2.3 versus 4.0 sec, p < 0.001). Operations performed in the university setting were associated with significantly more images (2.7 versus 1.8 images, p < 0.001), longer total exposure times (3.2 versus 2.3 sec, p = 0.0027), and total radiation dose (27.8 versus 53.3 rad, p < 0.001) when compared with those performed in the private setting. The university practice setting was associated with significantly more images (2.7 versus 1.8 images, p < 0.001), longer total exposure times (3.2 versus 2.3 sec, p = 0.003), and total radiation dose (27.8 versus 53.3 rad, p < 0.001) when compared with non-university settings. Large private and university hospitals had higher surgeon ratings. The university setting was associated with larger and less consistent surgical teams and lower nurse ratings. Surgical staff awareness of the procedure and attention to preoperative tasks specific to the procedure reduced pre-operative time spent in the OR as well as fluoroscopy radiation. These data suggest that nurses and support staff make substantial contributions to overall quality of care, and that leadership and interpersonal coordination are especially important within large teams at teaching hospitals.

  16. Cost drivers in total hip arthroplasty: effects of procedure volume and implant selling price.

    PubMed

    Kelly, Michael P; Bozic, Kevin J

    2009-01-01

    Total hip arthroplasty (THA), though a highly effective procedure for patients with end-stage hip disease, has become increasingly costly, both because of increasing procedure volume and because of the introduction and widespread use of new technologies. Data regarding procedure volume and procedure costs for THA were obtained from the National Inpatient Sample and other published sources for the years 1995 through 2005. Procedure volume increased 61% over the period studied. When adjusted for inflation, using the medical consumer price index, the average selling price of THA implants increased 24%. The selling price of THA implants as a percentage of total procedure costs increased from 29% to 60% during the period under study. The increasing cost of THA in the United States is a result of both increased procedure volume and increased cost of THA implants. No long-term outcome studies related to use of new implant technologies are available, and short-term results have been similar to those obtained with previous generations of THA implants. This study reinforces the need for a US total joint arthroplasty registry and for careful clinical and economic analyses of new technologies in orthopedics.

  17. Return to Driving After Hip Arthroscopy.

    PubMed

    Momaya, Amit M; Stavrinos, Despina; McManus, Benjamin; Wittig, Shannon M; Emblom, Benton; Estes, Reed

    2018-05-01

    The objective of this study was to evaluate patients' braking performance using a modern driving simulator after undergoing a right hip arthroscopy. This prospective study included 5 total driving sessions at which measurements were taken. The study was conducted at an academic medical center. A total of 14 patients scheduled to undergo a right hip arthroscopy were enrolled and compared with a control group of 17 participants to account for a potential learning phenomenon. Patients drove in the simulator preoperatively to establish a baseline, and then drove again at 2, 4, 6, and 8 weeks postoperatively. The control group did not undergo any type of surgical procedure. The main independent variable was time from surgery. A modern driving simulator was used to measure initial reaction time (IRT), throttle release time (TRT), foot movement time (FMT), and brake travel time (BTT). The braking reaction time (BRT) was calculated as the sum of IRT + TRT + FMT, and the total braking time (TBT) was calculated as the sum of BRT + BTT. The experimental group showed no significant changes in BTT (P = 0.11, (Equation is included in full-text article.)= 0.04) nor TBT (P = 0.20, (Equation is included in full-text article.)= 0.03) over the duration of 8 weeks. Although the experimental group did exhibit significant improvements in IRT (P = 0.002), TRT (P < 0.0001), FMT (P < 0.0001), and BRT (P = 0.0002) between preoperative and 2 weeks postoperative driving sessions, there were no significant changes thereafter. The mean preoperative TBT and 2 weeks postoperative TBT for the experimental group were 3.07 seconds (SD = 0.50) and 2.97 seconds (SD = 0.57), respectively. No learning phenomenon was observed in the control group. This study's findings suggest that patients may return to driving 2 weeks postoperatively from a right-sided hip arthroscopy procedure.

  18. A comparative study of female sterilization via modified Uchida and silver clip techniques in rural China.

    PubMed

    Qiu, Hongyan; Li, Li; Wu, Shangchun; Liang, Hong; Yuan, Wei; He, Yingqin

    2011-03-01

    To compare the specific effects of 2 female sterilization methods: the modified Uchida technique and the application of silver clips. A total of 2198 women living in rural areas who were still of reproductive age but opting for sterilization were enrolled. The participants were randomly divided into 2 groups, and underwent sterilization by either modified Uchida technique or silver clips. Information on acceptability, operation conditions, effectiveness, adverse effects, and complaints was collected 3, 6, and 12 months after the procedure. No significant difference in effectiveness, adverse effects or chief complaints between the 2 procedures was found. Differences in operative outcome, bleeding volume during the procedure, and operation time were found. A shorter operation time and less bleeding for the silver clip method indicated that female sterilization by this technique was as safe as that by modified Uchida technique. Copyright © 2010 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  19. Orthodontic treatment of an anterior openbite with the aid of corticotomy procedure: Case report

    PubMed Central

    Aljhani, Ali S.; Aldrees, Abdullah M.

    2010-01-01

    This case report illustrates the orthodontic treatment combined with the corticotomy technique in an adult patient to accelerate tooth movement and shorten the treatment time. The patient was a 22-year-old woman with an anterior open bite and flared and spaced upper and lower incisors. First, fixed orthodontic appliances (bidimensional edgewise brackets) were bonded, and a week later buccal and lingual corticotomy with alveolar augmentation procedure in the maxillary arch from the first molar to the contralateral first molar, and from canine to canine in the mandibular arch was performed. Orthodontic therapy proceeded with frequent activation of the appliances to retract the incisors every 2 weeks. The total treatment time was 5 months and no adverse effects were observed at the end of active treatment. The addition of the decortication procedure to the conventional orthodontic therapy decreased the duration of treatment significantly. Successful closure of the anterior open bite with adequate overbite and interdigitation of the teeth were achieved. PMID:24151417

  20. Optical urethrotomy under local anaesthesia is a feasible option in urethral stricture disease.

    PubMed

    Munks, D G; Alli, M O; Goad, E H Abdel

    2010-01-01

    The aim of our study was to assess the feasibility of performing optical urethrotomy for urethral stricture disease under local anaesthesia. A total of 33 patients with radiologically proven urethral stricture underwent optical urethrotomy by a single operator under local anaesthesia. Of these patients, 23 (70%) had stricture involving the corpora spongiosum and 18 (55%) of the patients were dependent on supra-pubic catheters. The procedure was successful in 30 cases (91%). The procedure was very well tolerated (average visual analogue pain score of 2/10) with an extremely low complication rate. The large number of patients with urethral stricture disease and the premium on operating time on formal theatre slates encouraged us to perform these procedures under local anaesthetic. Although most patients had severe stricture disease, the majority of cases were successful and very well tolerated. Optical urethrotomy under local anesthesia could be a viable option in the absence of formal theatre time and the facilities to perform general anaesthesia.

  1. Orthodontic treatment of an anterior openbite with the aid of corticotomy procedure: Case report.

    PubMed

    Aljhani, Ali S; Aldrees, Abdullah M

    2011-04-01

    This case report illustrates the orthodontic treatment combined with the corticotomy technique in an adult patient to accelerate tooth movement and shorten the treatment time. The patient was a 22-year-old woman with an anterior open bite and flared and spaced upper and lower incisors. First, fixed orthodontic appliances (bidimensional edgewise brackets) were bonded, and a week later buccal and lingual corticotomy with alveolar augmentation procedure in the maxillary arch from the first molar to the contralateral first molar, and from canine to canine in the mandibular arch was performed. Orthodontic therapy proceeded with frequent activation of the appliances to retract the incisors every 2 weeks. The total treatment time was 5 months and no adverse effects were observed at the end of active treatment. The addition of the decortication procedure to the conventional orthodontic therapy decreased the duration of treatment significantly. Successful closure of the anterior open bite with adequate overbite and interdigitation of the teeth were achieved.

  2. Comparison of totally laparoscopic total gastrectomy using an endoscopic linear stapler with laparoscopic-assisted total gastrectomy using a circular stapler in patients with gastric cancer: A single-center experience.

    PubMed

    Gong, Chung Sik; Kim, Byung Sik; Kim, Hee Sung

    2017-12-28

    To evaluate the safety and efficacy of totally laparoscopic total gastrectomy (TLTG) with esophagojejunostomy using a linear stapler compared with laparoscopic-assisted total gastrectomy (LATG) using a circular stapler in gastric cancer patients. We retrospectively reviewed 687 patients who underwent laparoscopic total gastrectomy for gastric cancer at a single institution from August 2008 to August 2014. The patients were divided into two groups according to the type of operation: 421 patients underwent TLTG and 266 underwent LATG. Clinicopathologic characteristics and surgical outcomes in the two groups were compared and analyzed. The TLTG group had higher mean ages at the time of operation (57.78 ± 11.20 years and 55.69 ± 11.96 years, P = 0.020) and more histories of abdominal surgery (20.2% and 12.4%, P = 0.008) compared with the LATG group. Surgical outcomes such as intraoperative and postoperative transfusions, combined operations, pain scores and administration of analgesics, and complications were similar between the two groups. However, compared with the LATG group, the TLTG group required a shorter operation time (149 min vs 170 min, P < 0.001), had lower postoperative hematocrit change (3.49% vs 4.04%, P = 0.002), less intraoperative events (3.1% vs 10.2%, P < 0.001), less intraoperative anastomosis events (2.4% vs 7.1%, P = 0.003), faster postoperative recovery such as median time to first flatus (3.30 d vs 3.60 d, P < 0.001), faster median commencement of soft diet (4.30 d vs 4.60 d, P < 0.001) and shorter length of postoperative hospital stay (6.75 d vs 7.02 d, P = 0.005). The intracorporeal method for reconstruction of esophagojejunostomy using a linear stapler may be considered a feasible procedure comparing with extracorporeal anastomosis using circular stapler because TLTG is simpler and more straightforward than LATG. Therefore, TLTG can be recommended as an appropriate procedure for gastric cancer.

  3. Comparison of totally laparoscopic total gastrectomy using an endoscopic linear stapler with laparoscopic-assisted total gastrectomy using a circular stapler in patients with gastric cancer: A single-center experience

    PubMed Central

    Gong, Chung Sik; Kim, Byung Sik; Kim, Hee Sung

    2017-01-01

    AIM To evaluate the safety and efficacy of totally laparoscopic total gastrectomy (TLTG) with esophagojejunostomy using a linear stapler compared with laparoscopic-assisted total gastrectomy (LATG) using a circular stapler in gastric cancer patients. METHODS We retrospectively reviewed 687 patients who underwent laparoscopic total gastrectomy for gastric cancer at a single institution from August 2008 to August 2014. The patients were divided into two groups according to the type of operation: 421 patients underwent TLTG and 266 underwent LATG. Clinicopathologic characteristics and surgical outcomes in the two groups were compared and analyzed. RESULTS The TLTG group had higher mean ages at the time of operation (57.78 ± 11.20 years and 55.69 ± 11.96 years, P = 0.020) and more histories of abdominal surgery (20.2% and 12.4%, P = 0.008) compared with the LATG group. Surgical outcomes such as intraoperative and postoperative transfusions, combined operations, pain scores and administration of analgesics, and complications were similar between the two groups. However, compared with the LATG group, the TLTG group required a shorter operation time (149 min vs 170 min, P < 0.001), had lower postoperative hematocrit change (3.49% vs 4.04%, P = 0.002), less intraoperative events (3.1% vs 10.2%, P < 0.001), less intraoperative anastomosis events (2.4% vs 7.1%, P = 0.003), faster postoperative recovery such as median time to first flatus (3.30 d vs 3.60 d, P < 0.001), faster median commencement of soft diet (4.30 d vs 4.60 d, P < 0.001) and shorter length of postoperative hospital stay (6.75 d vs 7.02 d, P = 0.005). CONCLUSION The intracorporeal method for reconstruction of esophagojejunostomy using a linear stapler may be considered a feasible procedure comparing with extracorporeal anastomosis using circular stapler because TLTG is simpler and more straightforward than LATG. Therefore, TLTG can be recommended as an appropriate procedure for gastric cancer. PMID:29358863

  4. Simulator-Based Angiography and Endovascular Neurosurgery Curriculum: A Longitudinal Evaluation of Performance Following Simulator-Based Angiography Training.

    PubMed

    Pannell, J Scott; Santiago-Dieppa, David R; Wali, Arvin R; Hirshman, Brian R; Steinberg, Jeffrey A; Cheung, Vincent J; Oveisi, David; Hallstrom, Jon; Khalessi, Alexander A

    2016-08-29

    This study establishes performance metrics for angiography and neuroendovascular surgery procedures based on longitudinal improvement in individual trainees with differing levels of training and experience. Over the course of 30 days, five trainees performed 10 diagnostic angiograms, coiled 10 carotid terminus aneurysms in the setting of subarachnoid hemorrhage, and performed 10 left middle cerebral artery embolectomies on a Simbionix Angio Mentor™ simulator. All procedures were nonconsecutive. Total procedure time, fluoroscopy time, contrast dose, heart rate, blood pressures, medications administered, packing densities, the number of coils used, and the number of stent-retriever passes were recorded. Image quality was rated, and the absolute value of technically unsafe events was recorded. The trainees' device selection, macrovascular access, microvascular access, clinical management, and the overall performance of the trainee was rated during each procedure based on a traditional Likert scale score of 1=fail, 2=poor, 3=satisfactory, 4=good, and 5=excellent. These ordinal values correspond with published assessment scales on surgical technique. After performing five diagnostic angiograms and five embolectomies, all participants demonstrated marked decreases in procedure time, fluoroscopy doses, contrast doses, and adverse technical events; marked improvements in image quality, device selection, access scores, and overall technical performance were additionally observed (p < 0.05). Similarly, trainees demonstrated marked improvement in technical performance and clinical management after five coiling procedures (p < 0.05). However, trainees with less prior experience deploying coils continued to experience intra-procedural ruptures up to the eighth embolization procedure; this observation likely corresponded with less tactile procedural experience to an exertion of greater force than appropriate for coil placement. Trainees across all levels of training and prior experience demonstrated a significant performance improvement after completion of our simulator curriculum consisting of five diagnostic angiograms, five embolectomy cases, and 10 aneurysm coil embolizations.

  5. The influence of a time-varying least squares parametric model when estimating SFOAEs evoked with swept-frequency tones

    NASA Astrophysics Data System (ADS)

    Hajicek, Joshua J.; Selesnick, Ivan W.; Henin, Simon; Talmadge, Carrick L.; Long, Glenis R.

    2018-05-01

    Stimulus frequency otoacoustic emissions (SFOAEs) were evoked and estimated using swept-frequency tones with and without the use of swept suppressor tones. SFOAEs were estimated using a least-squares fitting procedure. The estimated SFOAEs for the two paradigms (with- and without-suppression) were similar in amplitude and phase. The fitting procedure minimizes the square error between a parametric model of total ear-canal pressure (with unknown amplitudes and phases) and ear-canal pressure acquired during each paradigm. Modifying the parametric model to allow SFOAE amplitude and phase to vary over time revealed additional amplitude and phase fine structure in the without-suppressor, but not the with-suppressor paradigm. The use of a time-varying parametric model to estimate SFOAEs without-suppression may provide additional information about cochlear mechanics not available when using a with-suppressor paradigm.

  6. Workflow in interventional radiology: uterine fibroid embolization (UFE)

    NASA Astrophysics Data System (ADS)

    Lindisch, David; Neumuth, Thomas; Burgert, Oliver; Spies, James; Cleary, Kevin

    2008-03-01

    Workflow analysis can be used to record the steps taken during clinical interventions with the goal of identifying bottlenecks and streamlining the procedure efficiency. In this study, we recorded the workflow for uterine fibroid embolization (UFE) procedures in the interventional radiology suite at Georgetown University Hospital in Washington, DC, USA. We employed a custom client/server software architecture developed by the Innovation Center for Computer Assisted Surgery (ICCAS) at the University of Leipzig, Germany. This software runs in a JAVA environment and enables an observer to record the actions taken by the physician and surgical team during these interventions. The data recorded is stored as an XML document, which can then be further processed. We recorded data from 30 patients and found a mean intervention time of 01:49:46 (+/- 16:04) minutes. The critical intervention step, the embolization, had a mean time of 00:15:42 (+/- 05:49) minutes, which was only 15% of the total intervention time.

  7. Knowledge of chronic total occlusion among Polish interventional cardiologists

    PubMed Central

    Zabojszcz, Michał; Dębski, Grzegorz; Marchewka, Jakub; Legutko, Jacek; Surowiec, Sławomir; Siudak, Zbigniew; Żmudka, Krzysztof; Dudek, Dariusz; Bryniarski, Leszek

    2015-01-01

    Introduction Chronic total occlusion (CTO) recanalization is indicated in patients with symptoms and evidence of ischemia, but in most cases those types of lesions are still treated medically. In the last few years CTO angioplasty technique has changed dramatically due to considerable advances in techniques and dedicated equipment. Aim An attempt to assess the state of knowledge of technical aspects of CTO angioplasty of coronary arteries among Polish interventional cardiologists. Material and methods Questionnaire survey performed during two major Polish invasive cardiology workshops. Results In the study there participated 113 physicians with an average length of work experience of 13 years, most of them cardiologists certified as independent primary operators. The majority of respondents recognized the need of prevention of thrombotic complications through control of activated coagulation time during the CTO procedures. Prevention of renal complications and X-ray protection are also recognized as a significant part of the procedures. The benefits from the use of over-the-wire microcatheters and balloons, the proper choice of dedicated guidewires, contralateral injections and retrograde technique are underestimated. Conclusions Despite satisfactory knowledge about indications and qualification for the CTO procedure, the awareness of procedural aspects (particularly the retrograde technique) as well as the dedicated CTO equipment among Polish interventional cardiologists is still insufficient. PMID:26161099

  8. Skin and Soft Tissue Surgery in the Office Versus Operating Room Setting: An Analysis Based on Individual-Level Medicare Data.

    PubMed

    Kantor, Jonathan

    2018-03-23

    The relative volume of skin and soft tissue excision and reconstructive procedures performed in the outpatient office versus facility (ambulatory surgical center or hospital) differs by specialty, and has major implications for quality of care, outcomes, development of guidelines, resident education, health care economics, and patient perception. To assess the relative volume of surgical procedures performed in each setting (office vs ambulatory surgery center [ASC]/hospital) by dermatologists and nondermatologists. A cross-sectional analytical study was performed using the Medicare public use file (PUF) for 2014, which includes every patient seen in an office, ASC, or hospital in the United States billed to Medicare part B. Data were divided by physician specialty and setting. A total of 9,316,307 individual encounters were included in the Medicare PUF. Dermatologists account for 195,001 (2.1%) of the total. Dermatologists were more likely to perform surgical procedures in an office setting only (odds ratio 5.48 [95% confidence interval 5.05-5.95], p < .0001) than other specialists in aggregate. More than 90% of surgical procedures are performed in an office setting, and dermatologists are more than 5 times as likely as other specialists to operate in an office setting.

  9. Comparison of transradial and transfemoral artery approach for percutaneous coronary angiography and angioplasty: a retrospective seven-year experience from a north Indian center.

    PubMed

    Tewari, Satyendra; Sharma, Naveen; Kapoor, Aditya; Syal, Sanjeev Kumar; Kumar, Sudeep; Garg, Naveen; Goel, Pravin K

    2013-01-01

    With the increasing prevalence of coronary artery disease, percutaneous coronary artery procedures have become even more important. Our study has compared transradial to transfemoral artery approach for coronary procedures in Indian population. Comparison of transradial and transfemoral artery approach for percutaneous coronary procedures. 26,238 patients, who underwent percutaneous coronary artery procedures, were divided into two groups depending upon transradial and transfemoral artery approach and compared for the various demographic and clinical characteristics, risk factors profile, vascular access and procedural details. 26,238 patients underwent percutaneous coronary procedures at our center. 81% were male and 19% were female. 55.65% and 44.35% procedures were done through transfemoral and transradial approach, respectively. 17,417 (66.38%) coronary angiographies were done, out of which 53.92% were transradial and 46.08% were transfemoral procedures. 8821 (33.62%) Percutaneous Transluminal Coronary Angioplasty (PTCA) were done, out of which 25.46% and 74.54% were done through transradial and transfemoral approach, respectively. Mean fluoroscopy time was 4.40 ± 3.55 min for transradial and 3.30 ± 3.66 min for transfemoral CAG (p < 0.001). For PTCA mean fluoroscopy time was 13.53 ± 2.53 min for transradial and 12.61 ± 9.524 min for transfemoral PTCA (p < 0.001). Minor and major procedure related complications and total duration of hospital stay were lower in transradial as compared to transfemoral group. The number of percutaneous transradial procedures have increased significantly with reduced complication rates and comparable success rate to transfemoral approach, along with the additional benefits to patient in terms of patient comfort, preference and reduced cost of health delivery. Copyright © 2013 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  10. The role of industry influence in sinus balloon dilation: Trends over time.

    PubMed

    Gadkaree, Shekhar K; Rathi, Vinay K; Gottschalk, Esther; Feng, Allen L; Phillips, Katie M; Scangas, George A; Metson, Ralph

    2018-05-08

    Balloon dilation (BD) is a controversial alternative to conventional sinus surgery. The role of industry on practice patterns remains unknown. The aim of this study was to determine whether industry payments from BD manufacturers influence practice patterns for otolaryngologists and evaluate how these payments change over time. Retrospective cohort study using Medicare Provider Utilization and Payment (PUP) Data and Center for Medicare and Medicaid Services Open Payments (OP) general payment datasets. A total of 294 otolaryngologists identified in the PUP dataset who performed BD procedures from January 1, 2013, to December 31, 2015, were cross-referenced in the OP dataset from January 1, 2014, to December 31, 2016, for BD manufacturer payments. Payments to surgeons performing BD stratified by amount, type, and number of procedures performed were primary outcome measures. Of the 294 otolaryngologists reporting BD procedures, 223 (76%) received payments from a company that manufactures BD devices. Receipt of $2,500 in BD payments was associated with performance of one additional BD procedure, and consulting fees were most positively associated with performing additional BD procedures (P = 0.006). The providers receiving the most in BD payments were more likely to continue to receive the most in payments, regardless of number of BD procedures performed. Performing more BD procedures did not correlate with decrease in other sinus procedures. Payments to otolaryngologists from manufacturers of sinus BD devices are associated with the performance of an increased number of such procedures. Surgeons should consider the impact of interactions with industry when evaluating patients for BD procedures. 4. Laryngoscope, 00:000-000, 2018. © 2018 The American Laryngological, Rhinological and Otological Society, Inc.

  11. Brachioplasty outcomes: a review of a multipractice cohort.

    PubMed

    Zomerlei, Terri A; Neaman, Keith C; Armstrong, Shannon D; Aitken, Marguerite E; Cullen, William T; Ford, Ronald D; Renucci, John D; VanderWoude, Douglas L

    2013-04-01

    Upper arm deformities secondary to massive weight loss or senile elastosis have led to an increased demand for aesthetic contouring procedures such as brachioplasty. The records of all patients who underwent a brachioplasty procedure from a multipractice medical center were reviewed. Outcomes measured included patient demographics, operative interventions, and postoperative course. Ninety-six patients were analyzed. Fifty-three patients (55.2 percent) underwent a concomitant procedure, with 53.1 percent undergoing arm liposuction at the time of brachioplasty. Major and minor complications rates were 17.7 percent and 44.8 percent, respectively. Common complications included hypertrophic scarring (24.0 percent) and infection (14.6 percent). The total revision rate was 22.9 percent, with residual contour deformity (40.9 percent of revisions) and hypertrophic scarring (36.4 percent of revisions) representing the most common causes for revision. Patients who underwent a previous bariatric procedure were at an increased risk of developing a major complication (p = 0.02). Concomitant upper arm liposuction and concomitant procedures were not associated with a significantly increased complication rate. Brachioplasty, despite being an effective treatment for contour irregularities of the upper arm, is associated with significant revision and complication rates. Post-bariatric surgery patients should be informed of the potential for increased complications. Additional procedures performed at the time of brachioplasty do not significantly increase complications. Liposuction of the upper arm can be performed safely in conjunction with brachioplasty.

  12. A novel quick transendoscopic enteral tubing in mid-gut: technique and training with video.

    PubMed

    Long, Chuyan; Yu, Yan; Cui, Bota; Jagessar, Sabreen Abdul Rahman; Zhang, Jie; Ji, Guozhong; Huang, Guangming; Zhang, Faming

    2018-03-13

    This study aimed to evaluate the feasibility, safety, and value of a quick technique for transendoscopic enteral tubing (TET) through mid-gut. A prospective interventional study was performed in a single center. A TET tube was inserted into mid-gut through the nasal orifice and fixed on the pylorus wall by one tiny titanium endoscopic clip under anesthesia. The feasibility, safety, success rate, and satisfaction with TET placement were evaluated for enteral nutrition or fecal microbiota transplantation. A total of 86 patients underwent mid-gut TET. The success rate of the TET procedure was 98.8% (85/86). Mean tubing time of the TET procedure was 4.2 ± 1.9 min. 10 cases of procedure was enough for training of general endoscopist to shorten the procedure time (7.0 min vs 4.0 min, p < 0.05). 97.7% (84/86) of patients were satisfied with the TET placement. Procedure-related and tube-related adverse events were observed in 8.1% (7/86) and 7.0% (6/86) of patients respectively. There were no moderate to severe adverse events during tube extubation. TET through mid-gut is a novel, convenient, reliable and safe procedure for mid-gut administration with a high degree of patient satisfaction. This research was retrospectively registered with clinicaltrials.gov. Trial registration date: 29th November 2017. NCT03335982 .

  13. Patient-specific simulation in carotid artery stenting.

    PubMed

    Willaert, Willem; Aggarwal, Rajesh; Bicknell, Colin; Hamady, Mo; Darzi, Ara; Vermassen, Frank; Cheshire, Nicholas

    2010-12-01

    Patient-specific virtual reality (VR) simulation is a technologic advancement that allows planning and practice of the carotid artery stenting (CAS) procedure before it is performed on the patient. The initial findings are reported, using this novel VR technique as a tool to optimize technical and nontechnical aspects of this complex endovascular procedure. In the angiography suite, the same interventional team performed the VR rehearsal and the actual CAS on the patient. All proceedings were recorded to allow for video analysis of team, technical, and nontechnical skills. Analysis of both procedures showed identical use of endovascular tools, similar access strategy, and a high degree of similarity between the angiography images. The total procedure time (24.04 vs 60.44 minutes), fluoroscopy time (11.19 vs 21.04 minutes), and cannulation of the common carotid artery (1.35 vs 9.34) took considerably longer in reality. An extensive questionnaire revealed that all team members found that the rehearsal increased the subjective sense of teamwork (4/5), communication (4/5), and patient safety (4/5). A VR procedure rehearsal is a practical and feasible preparatory tool for CAS and shows a high correlation with the real procedure. It has the potential to enhance the technical, nontechnical, and team performance. Further research is needed to evaluate if this technology can lead to improved outcomes for patients. Copyright © 2010 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  14. The laboratory of the 1990s—Planning for total automation

    PubMed Central

    Brunner, Linda A.

    1992-01-01

    The analytical laboratory of the 1990s must be able to meet and accommodate the rapid evolution of modern-day technology. One such area is laboratory automation. Total automation may be seen as the coupling of computerized sample tracking, electronic documentation and data reduction with automated sample handling, preparation and analysis, resulting in a complete analytical procedure with minimal human involvement. Requirements may vary from one laboratory or facility to another, so the automation has to be flexible enough to cover a wide range of applications, and yet fit into specific niches depending on individual needs. Total automation must be planned for, well in advance, if the endeavour is to be a success. Space, laboratory layout, proper equipment, and the availability and access to necessary utilities must be taken into account. Adequate training and experience of the personnel working with the technology must also be ensured. In addition, responsibilities of installation, programming maintenance and operation have to be addressed. Proper time management and the efficient implementation and use of total automation are also crucial to successful operations. This paper provides insights into laboratory organization and requirements, as well as discussing the management issues that must be faced when automating laboratory procedures. PMID:18924925

  15. Infected total knee arthroplasty treated with arthrodesis using a modular nail.

    PubMed

    Waldman, B J; Mont, M A; Payman, K R; Freiberg, A A; Windsor, R E; Sculco, T P; Hungerford, D S

    1999-10-01

    Failed treatment of infected total knee replacement presents few attractive surgical options. Knee arthrodesis is challenging surgically and can be complicated by nonunion, malunion, or recurrent infection. Recently, a modular titanium intramedullary nail has been used in an attempt to reduce the incidence of nonunion and the rate of complications. In the present study, a review of the results of knee arthrodesis after infected total knee arthroplasty in 21 patients at three large academic institutions was performed. All patients were followed up for a mean of 2.4 years (range, 2-7.5 years). The mean age of the patients was 64 years. The mean number of previous operations was four (range, 2-9 operations). A solid arthrodesis was achieved without additional surgical treatment in 20 of 21 patients (95%). The mean time to fusion was 6.3 months. The one patient who suffered a nonunion achieved fusion after a subsequent bone grafting procedure. Based on the present study, intramedullary arthrodesis with a coupled titanium nail, is a reliable, effective method of achieving fusion after infection of a total knee arthroplasty. This procedure resulted in a high rate of fusion and a lower rate of complications when compared with traditional methods of arthrodesis.

  16. Female Sex Is a Risk Factor for Failure of Hip Arthroscopy Performed for Acetabular Retroversion

    PubMed Central

    Poehling-Monaghan, Kirsten L.; Krych, Aaron J.; Levy, Bruce A.; Trousdale, Robert T.; Sierra, Rafael J.

    2017-01-01

    Background: The success of hip surgery in treating acetabular retroversion depends on the severity of the structural deformity and on selecting the correct patient for open or arthroscopic procedures. Purpose: To compare a group of patients with retroverted hips treated successfully with hip arthroscopy with a group of patients with retroverted hips that failed arthroscopic surgery, with special emphasis on (1) patient characteristics, (2) perioperative radiographic parameters, (3) intraoperative findings and concomitant procedures, and (4) patient sex. Study Design: Case-control study; Level of evidence, 3. Methods: We retrospectively reviewed the charts of 47 adult patients (47 hips) with acetabular retroversion who had undergone hip arthroscopy. Retroversion was based on the presence of an ischial spine sign in addition to either a crossover or posterior wall sign on a well-positioned anteroposterior pelvic radiograph. A total of 24 hips (50%) (16 females, 8 males; mean patient age, 31 years) had failed arthroscopy, defined as modified Harris Hip Score (mHHS) <80 or need for subsequent procedure. Twenty-three hips (8 females, 15 males; mean patient age, 29 years) were considered successful, defined as having no subsequent procedures and an mHHS >80 at the time of most recent follow-up. Perioperative variables, radiographic characteristics, and intraoperative findings were compared between the groups, in addition to a subgroup analysis based on sex. Results: The mean follow-up for successful hips was 30 months (SD, 11 months), with a mean mHHS of 95. In the failure group, 6 patients required subsequent procedures (4 anteverting periacetabular osteotomies and 2 total hip arthroplasties). The mean overall time to failure was 21 months, and the mean time to a second procedure was 24 months (total hip arthroplasty, 29.5 months; periacetabular osteotomy, 21.2 months); 18 hips failed on the basis of a low mHHS (mean, 65; range, 27-79) at last follow-up. Factors significantly different between the success and failure groups included patient sex, with males being more likely than females to have a successful outcome (P < .02), as well as undergoing femoral osteoplasty (P < .02). Intraoperative variables that were associated with worse outcome included isolated labral debridement (P < .002). In a subgroup analysis, males were more likely than their female counterparts to have a successful outcome with both isolated cam and combined cam-pincer resection (P < .05). Level of crossover correction on postoperative radiographs had no correlation with outcome. Conclusion: Acetabular retroversion remains a challenging pathoanatomy to treat arthroscopically. If hip arthroscopy is to be considered in select cases, we recommend labral preservation when possible. Male patients with correction of cam deformities did well, while females with significant retroversion appeared to be at greater risk for failure of arthroscopic treatment. PMID:29164164

  17. Multimodality Non-Rigid Image Registration for Planning, Targeting and Monitoring during CT-guided Percutaneous Liver Tumor Cryoablation

    PubMed Central

    Elhawary, Haytham; Oguro, Sota; Tuncali, Kemal; Morrison, Paul R.; Tatli, Servet; Shyn, Paul B.; Silverman, Stuart G.; Hata, Nobuhiko

    2010-01-01

    Rationale and Objectives To develop non-rigid image registration between pre-procedure contrast enhanced MR images and intra-procedure unenhanced CT images, to enhance tumor visualization and localization during CT-guided liver tumor cryoablation procedures. Materials and Methods After IRB approval, a non-rigid registration (NRR) technique was evaluated with different pre-processing steps and algorithm parameters and compared to a standard rigid registration (RR) approach. The Dice Similarity Coefficient (DSC), Target Registration Error (TRE), 95% Hausdorff distance (HD) and total registration time (minutes) were compared using a two-sided Student’s t-test. The entire registration method was then applied during five CT-guided liver cryoablation cases with the intra-procedural CT data transmitted directly from the CT scanner, with both accuracy and registration time evaluated. Results Selected optimal parameters for registration were section thickness of 5mm, cropping the field of view to 66% of its original size, manual segmentation of the liver, B-spline control grid of 5×5×5 and spatial sampling of 50,000 pixels. Mean 95% HD of 3.3mm (2.5x improvement compared to RR, p<0.05); mean DSC metric of 0.97 (13% increase); and mean TRE of 4.1mm (2.7x reduction) were measured. During the cryoablation procedure registration between the pre-procedure MR and the planning intra-procedure CT took a mean time of 10.6 minutes, the MR to targeting CT image took 4 minutes and MR to monitoring CT took 4.3 minutes. Mean registration accuracy was under 3.4mm. Conclusion Non-rigid registration allowed improved visualization of the tumor during interventional planning, targeting and evaluation of tumor coverage by the ice ball. Future work is focused on reducing segmentation time to make the method more clinically acceptable. PMID:20817574

  18. Atrial fibrillation ablation using very short duration 50 W ablations and contact force sensing catheters.

    PubMed

    Winkle, Roger A; Moskovitz, Ryan; Hardwin Mead, R; Engel, Gregory; Kong, Melissa H; Fleming, William; Salcedo, Jonathan; Patrawala, Rob A; Tranter, John H; Shai, Isaac

    2018-06-01

    The optimal radiofrequency (RF) power and lesion duration using contact force (CF) sensing catheters for atrial fibrillation (AF) ablation are unknown. We evaluate 50 W RF power for very short durations using CF sensing catheters during AF ablation. We evaluated 51 patients with paroxysmal (n = 20) or persistent (n = 31) AF undergoing initial RF ablation. A total of 3961 50 W RF lesions were given (average 77.6 ± 19.1/patient) for an average duration of only 11.2 ± 3.7 s. As CF increased from < 10 to > 40 g, the RF application duration decreased from 13.7 ± 4.4 to 8.6 ± 2.5 s (p < 0.0005). Impedance drops occurred in all ablations, and for patients in sinus rhythm, there was loss of pacing capture during RF delivery suggesting lesion creation. Only 3% of the ablation lesions were at < 5 g and 1% at > 40 g of force. As CF increased, the force time integral (FTI) increased from 47 ± 24 to 376 ± 102 gs (p < 0.0005) and the lesion index (LSI) increased from 4.10 ± 0.51 to 7.63 ± 0.50 (p < 0.0005). Both procedure time (101 ± 19.7 min) and total RF energy time (895 ± 258 s) were very short. For paroxysmal AF, the single procedure freedom from AF was 86% at 1 and 2 years. For persistent AF, it was 83% at 1 year and 72% at 2 years. There were no complications. Short duration 50 W ablations using CF sensing catheters are safe and result in excellent long-term freedom from AF for both paroxysmal and persistent AF with short procedure times and small amounts of total RF energy delivery.

  19. Substantial superiority of Niobe ES over Niobe II system in remote-controlled magnetic pulmonary vein isolation.

    PubMed

    Da Costa, Antoine; Guichard, Jean Baptiste; Maillard, Nicolas; Romeyer-Bouchard, Cécile; Gerbay, Antoine; Isaaz, Karl

    2017-03-01

    Catheter ablation of atrial fibrillation (AFib) primarily relies upon pulmonary vein isolation (PVI), but such procedures are associated with significant X-ray exposure. The newer Epoch system has been developed so as to enable more precise magnetic navigation whilst limiting X-ray exposure. This study was aimed at quantifying both exposure time and X-ray reduction with the newer Epoch system compared to Niobe II during AFib ablation procedures. From November 2011 to November 2013, our last 92 consecutive patients treated with the Niobe ES (Epoch Solution; 4th generation magnetic navigation technology) system were compared with the first 92 consecutive patients treated using the Niobe II system (3rd generation magnetic navigation technology) for symptomatic drug-refractory AFib. Mean patient age was 59±11years (20% female), and the study population was affected by either symptomatic paroxysmal (65.2%) or persistent (34.8%) AFib. Median procedure time was 2±0.5h and median total X-ray exposure 12.3±6.4min. Procedure time (1.9±0.4 vs. 2.7±1h, p<0.0001) and X-ray duration (12±4 vs. 15±7min, p=0.001) were significantly lower with Niobe ES than with the Niobe II system. X-ray ablation exposure time was also significantly lower with the Niobe ES system than with the Niobe II system (2.9±2 vs. 4±3.5min; p=0.01). Through multivariate analysis, the only predictive factors influencing both procedure duration and X-ray exposure were found to be the Niobe ES system use and LA size. Our study was the first to demonstrate that the new Niobe ES magnetic robotic system substantially reduced overall operating, fluoroscopy, and ablation times during AFib ablation procedure. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Optimizing radiofrequency ablation of paroxysmal and persistent atrial fibrillation by direct catheter force measurement-a case-matched comparison in 198 patients.

    PubMed

    Sigmund, Elisabeth; Puererfellner, Helmut; Derndorfer, Michael; Kollias, Georgios; Winter, Siegmund; Aichinger, Josef; Nesser, Hans-Joachim; Martinek, Martin

    2015-02-01

    Sufficient electrode-tissue contact is crucial for adequate lesion formation in radiofrequency catheter ablation (RFCA). We assessed the impact of direct catheter force measurement on acute procedural parameters and outcome of RFCA for paroxysmal and persistent atrial fibrillation (AF). Ninety-nine consecutive patients (70% men) with paroxysmal (63.6%) or persistent AF underwent left atrial RFCA using a 3.5-mm open-irrigated-tip (OIT) catheter with contact force measurement capabilities (group 1). For comparison a case-matched cohort with standard OIT catheters was used (99 patients; group 2). Case matching included gender, type of AF, number or RFCA procedures, and type of procedure. Procedural data showed a significant decline in radiofrequency ablation time from 52 ± 20 to 44 ± 16 minutes (P = 0.003) with a remarkable mean reduction in overall procedure time of 34 minutes (P = 0.0001; 225.8 ± 53.1 vs 191.9 ± 53.3 minutes). In parallel, the total fluoroscopy time could be significantly reduced from 28.5 ± 11.0 to 19.9 ± 9.3 minutes (P = 0.0001) as well as fluoroscopy dose from 74.1 ± 58.0 to 56.7 ± 38.9 Gy/cm(2) (P = 0.016). Periprocedural complications were similar in both groups. The use of contact force sensing technology is able to significantly reduce ablation, procedure, and fluoroscopy times as well as dose in RFCA of AF in a mixed case-matched group of paroxysmal and persistent AF. Energy delivery is substantially reduced by avoiding radiofrequency ablation in positions with insufficient surface contact. Additionally 12-month outcome data showed increased efficacy. Such time saving and equally safe technology may have a relevant impact on laboratory management and increased cost effectiveness. © 2014 Wiley Periodicals, Inc.

  1. Real-time magnetic resonance-guided ablation of typical right atrial flutter using a combination of active catheter tracking and passive catheter visualization in man: initial results from a consecutive patient series.

    PubMed

    Hilbert, Sebastian; Sommer, Philipp; Gutberlet, Matthias; Gaspar, Thomas; Foldyna, Borek; Piorkowski, Christopher; Weiss, Steffen; Lloyd, Thomas; Schnackenburg, Bernhard; Krueger, Sascha; Fleiter, Christian; Paetsch, Ingo; Jahnke, Cosima; Hindricks, Gerhard; Grothoff, Matthias

    2016-04-01

    Recently cardiac magnetic resonance (CMR) imaging has been found feasible for the visualization of the underlying substrate for cardiac arrhythmias as well as for the visualization of cardiac catheters for diagnostic and ablation procedures. Real-time CMR-guided cavotricuspid isthmus ablation was performed in a series of six patients using a combination of active catheter tracking and catheter visualization using real-time MR imaging. Cardiac magnetic resonance utilizing a 1.5 T system was performed in patients under deep propofol sedation. A three-dimensional-whole-heart sequence with navigator technique and a fast automated segmentation algorithm was used for online segmentation of all cardiac chambers, which were thereafter displayed on a dedicated image guidance platform. In three out of six patients complete isthmus block could be achieved in the MR scanner, two of these patients did not need any additional fluoroscopy. In the first patient technical issues called for a completion of the procedure in a conventional laboratory, in another two patients the isthmus was partially blocked by magnetic resonance imaging (MRI)-guided ablation. The mean procedural time for the MR procedure was 109 ± 58 min. The intubation of the CS was performed within a mean time of 2.75 ± 2.21 min. Total fluoroscopy time for completion of the isthmus block ranged from 0 to 7.5 min. The combination of active catheter tracking and passive real-time visualization in CMR-guided electrophysiologic (EP) studies using advanced interventional hardware and software was safe and enabled efficient navigation, mapping, and ablation. These cases demonstrate significant progress in the development of MR-guided EP procedures. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  2. [Transurethral resection of bladder tumors and prostate enlargement in physiological saline solution (TURIS). A prospective study].

    PubMed

    Rose, A; Suttor, S; Goebell, P J; Rossi, R; Rübben, H

    2007-09-01

    Transurethral resection in a conductive irrigant medium is a new procedure in the surgical therapy of bladder tumors and prostate enlargement. In this prospective randomized trial we compared conventional TUR with TUR in saline regarding safety and efficiency. Between November 2004 and February 2005 a total number of 128 patients were included in this study. After randomization 58 patients were treated by conventional TUR and 70 patients by TURIS (Olympus, SurgMasterSystem). We evaluated resection time, weight of resected tissue, complications, blood loss, changes in serum sodium, and duration of catheterization. Among the tested procedures no statistically significant difference could be observed concerning blood loss, change of serum sodium, and complications. The mean weight of resected tissue of the prostate per time was 0.9 g/min with the TUR procedure and 0.8 g/min with the TURIS procedure. Severe complications like TUR syndrome or perforation of the bladder were not observed at all. In the TURIS group time until catheter removal was longer but also the mean weight of resected tissue of the prostate was higher in the TURIS group (42 g) than in the conventional TUR group (31 g). Transurethral resection in a conductive irrigant medium (TURIS) can be considered as a safe and effective surgical procedure in the treatment of BPH and superficial urothelial carcinoma. Moreover the risk of TUR syndrome and perforation of the bladder due to nerve stimulation is reduced.

  3. Impact of Lead Time and Safety Factor in Mixed Inventory Models with Backorder Discounts

    NASA Astrophysics Data System (ADS)

    Lo, Ming-Cheng; Chao-Hsien Pan, Jason; Lin, Kai-Cing; Hsu, Jia-Wei

    This study investigates the impact of safety factor on the continuous review inventory model involving controllable lead time with mixture of backorder discount and partial lost sales. The objective is to minimize the expected total annual cost with respect to order quantity, backorder price discount, safety factor and lead time. A model with normal demand is also discussed. Numerical examples are presented to illustrate the procedures of the algorithms and the effects of parameters on the result of the proposed models are analyzed.

  4. 40 CFR 63.772 - Test methods, compliance procedures, and compliance demonstrations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... conduct a performance test to determine percent emission reduction or outlet organic HAP or TOC... intervals in time, such as 15-minute intervals during the run. (B) The mass rate of either TOC (minus... either TOC (minus methane and ethane) or total HAP at the inlet of the control device (Ei) may be...

  5. 40 CFR 63.1282 - Test methods, compliance procedures, and compliance demonstrations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... organic HAP or TOC concentration when a flare is used. (3) For a performance test conducted to demonstrate... intervals in time, such as 15-minute intervals during the run. (B) The mass rate of either TOC (minus... either TOC (minus methane and ethane) or total HAP at the inlet of the control device (Ei) may be...

  6. 30 CFR 75.1325 - Firing procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Shots shall be fired by a qualified person or a person working in the presence of and under the direction of a qualified person. (b) Only one face in a working place shall be blasted at a time, except... kerf and no more than a total of 20 shots connected in a single series are fired in the round. A permit...

  7. 30 CFR 75.1325 - Firing procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Shots shall be fired by a qualified person or a person working in the presence of and under the direction of a qualified person. (b) Only one face in a working place shall be blasted at a time, except... kerf and no more than a total of 20 shots connected in a single series are fired in the round. A permit...

  8. 30 CFR 75.1325 - Firing procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Shots shall be fired by a qualified person or a person working in the presence of and under the direction of a qualified person. (b) Only one face in a working place shall be blasted at a time, except... kerf and no more than a total of 20 shots connected in a single series are fired in the round. A permit...

  9. 30 CFR 75.1325 - Firing procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Shots shall be fired by a qualified person or a person working in the presence of and under the direction of a qualified person. (b) Only one face in a working place shall be blasted at a time, except... kerf and no more than a total of 20 shots connected in a single series are fired in the round. A permit...

  10. 30 CFR 75.1325 - Firing procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Shots shall be fired by a qualified person or a person working in the presence of and under the direction of a qualified person. (b) Only one face in a working place shall be blasted at a time, except... kerf and no more than a total of 20 shots connected in a single series are fired in the round. A permit...

  11. PROCEDURE FOR THE ESTABLISHMENT OF COMMUNITY JUNIOR COLLEGES IN ARKANSAS.

    ERIC Educational Resources Information Center

    Arkansas State Commission on Coordination of Higher Educational Finance, Little Rock.

    CRITERIA FOR ESTABLISHMENT OF JUNIOR COLLEGE DISTRICTS IN ARKANSAS INCLUDE (1) A PROJECTED ENROLLMENT OF AT LEAST 300 FULL TIME EQUIVALENT STUDENTS IN THE THIRD YEAR OF OPERATION, (2) ASSESSED VALUATION ADEQUATE TO PROVIDE FROM LOCAL PROPERTY TAXES ONE-THIRD OF THE ANNUAL OPERATING COST AND THE TOTAL DEBT SERVICE REQUIREMENTS FOR CAPITAL OUTLAY,…

  12. Should Subtotal Thyroidectomy Be Abandoned in Multinodular Goiter Patients From Endemic Regions Requiring Surgery?

    PubMed Central

    Yoldas, Tayfun; Makay, Ozer; Icoz, Gokhan; Kose, Timur; Gezer, Gulten; Kismali, Erkan; Tamsel, Sadık; Ozbek, Sureyya; Yılmaz, Mustafa; Akyildiz, Mahir

    2015-01-01

    The most convenient surgical procedure for benign thyroid diseases is still controversial. The aim of this study is to determine the recurrence rate and risk factors for recurrence after different thyroidectomy procedures in multinodular goiter patients. Patients were separated into two groups according to the detection of a recurrent nodule or not after thyroidectomy. Of the 748 patients, 216 (29%) had recurrence, while 532 had no recurrent nodule. The difference between surgical procedures described as subtotal (ST), near total (NT) and total thyroidectomy (TT) was statistically significant. Transient hypoparathyroidism was significantly higher in NT and TT, when compared to ST patients (P < 0.05). Young age, bilateral multinodular goiter and insufficient surgery are risk factors affecting recurrence for benign nodular thyroid disease. Currently, subtotal procedures should be discontinued and total or near total procedures should be preferred. Meanwhile, the probability of a higher risk of hypoparathyroidism should be kept in mind. PMID:25594634

  13. [Custom-made implant for complex facial reconstruction: A case of total replacement of temporo-mandibular joint, zygomatic arch and malar bone].

    PubMed

    Guillier, D; Moris, V; See, L-A; Girodon, M; Wajszczak, B-L; Zwetyenga, N

    2017-02-01

    Total prosthetic replacement of the temporo-mandibular joint (TMJ) has become a common procedure, but it is usually limited to the TMJ itself. We report about one case of complex prosthetic joint reconstruction extending to the neighbouring bony structures. A 57-year-old patient, operated several times for a cranio-facial fibrous dysplasia, presented with a recurring TMJ ankylosis and a complexe latero-facial bone loss on the right side. We performed a reconstruction procedure including the TMJ, the zygomatic arch and the malar bone by mean of custom made composite prosthesis (chrome-cobalt-molybdenum-titanium and polyethylene). Five years postoperatively, mouth opening, nutrition, pain and oral hygiene were significantly improved. Nowadays technical possibilities allow for complex facial alloplastic reconstructions with good medium term results. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  14. CTA with fluoroscopy image fusion guidance in endovascular complex aortic aneurysm repair.

    PubMed

    Sailer, A M; de Haan, M W; Peppelenbosch, A G; Jacobs, M J; Wildberger, J E; Schurink, G W H

    2014-04-01

    To evaluate the effect of intraoperative guidance by means of live fluoroscopy image fusion with computed tomography angiography (CTA) on iodinated contrast material volume, procedure time, and fluoroscopy time in endovascular thoraco-abdominal aortic repair. CTA with fluoroscopy image fusion road-mapping was prospectively evaluated in patients with complex aortic aneurysms who underwent fenestrated and/or branched endovascular repair (FEVAR/BEVAR). Total iodinated contrast material volume, overall procedure time, and fluoroscopy time were compared between the fusion group (n = 31) and case controls (n = 31). Reasons for potential fusion image inaccuracy were analyzed. Fusion imaging was feasible in all patients. Fusion image road-mapping was used for navigation and positioning of the devices and catheter guidance during access to target vessels. Iodinated contrast material volume and procedure time were significantly lower in the fusion group than in case controls (159 mL [95% CI 132-186 mL] vs. 199 mL [95% CI 170-229 mL], p = .037 and 5.2 hours [95% CI 4.5-5.9 hours] vs. 6.3 hours (95% CI 5.4-7.2 hours), p = .022). No significant differences in fluoroscopy time were observed (p = .38). Respiration-related vessel displacement, vessel elongation, and displacement by stiff devices as well as patient movement were identified as reasons for fusion image inaccuracy. Image fusion guidance provides added value in complex endovascular interventions. The technology significantly reduces iodinated contrast material dose and procedure time. Copyright © 2014 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  15. The Kjeldahl method as a primary reference procedure for total protein in certified reference materials used in clinical chemistry. II. Selection of direct Kjeldahl analysis and its preliminary performance parameters.

    PubMed

    Vinklárková, Bára; Chromý, Vratislav; Šprongl, Luděk; Bittová, Miroslava; Rikanová, Milena; Ohnútková, Ivana; Žaludová, Lenka

    2015-01-01

    To select a Kjeldahl procedure suitable for the determination of total protein in reference materials used in laboratory medicine, we reviewed in our previous article Kjeldahl methods adopted by clinical chemistry and found an indirect two-step analysis by total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. In this article, we compare both procedures on various reference materials. An indirect Kjeldahl method gave falsely lower results than a direct analysis. Preliminary performance parameters qualify the direct Kjeldahl analysis as a suitable primary reference procedure for the certification of total protein in reference laboratories.

  16. The cost analysis of cemented versus cementless total hip replacement operations on the NHS.

    PubMed

    Kallala, R; Anderson, P; Morris, S; Haddad, F S

    2013-07-01

    In a time of limited resources, the debate continues over which types of hip prosthesis are clinically superior and more cost-effective. Orthopaedic surgeons increasingly need robust economic evidence to understand the full value of the operation, and to aid decision making on the 'package' of procedures that are available and to justify their practice beyond traditional clinical preference. In this paper we explore the current economic debate about the merits of cemented and cementless total hip replacement, an issue that continues to divide the orthopaedic community.

  17. Significance of Urinary Tract Involvement in Patients Treated with Cytoreductive Surgery (CRS) and Hyperthermic Intraperitoneal Chemotherapy (HIPEC)

    PubMed Central

    Randle, Reese W.; Craven, Brandon; Swett, Katrina R.; Levine, Edward A.; Shen, Perry; Stewart, John H.; Mirzazadeh, Majid

    2014-01-01

    Background Urinary tract involvement in patients with peritoneal surface disease treated with cytoreductive surgery (CRS) and hyperthermic intraperitoneal chemotherapy (HIPEC) often requires complex urologic resections and reconstruction to achieve optimal cytoreduction. The impact of these combined procedures on surgical outcomes is not well defined. Methods A prospective database of CRS/HIPEC procedures was analyzed retrospectively. Type of malignancy, performance status, resection status, hospital and intensive care unit stay, morbidity, mortality, and overall survival were reviewed. Results A total of 864 patients underwent 933 CRS/HI-PEC procedures, while 64 % (550) had preoperative ureteral stent placement. A total of 7.3 % had an additional urologic procedure without an increase in 30-day (p = 0.4) or 90-day (p = 1.0) mortality. Urologic procedures correlated with increased length of operating time (p < 0.001), blood loss (p < 0.001), and length of hospitalization (p = 0.003), yet were not associated with increased overall 30-day major morbidity (grade III/IV, p = 0.14). In multivariate analysis, independent predictors of additional urologic procedures were prior surgical score (p < 0.001), number of resected organs (p = 0.001), and low anterior resection (p = 0.03). Long-term survival was not statistically different between patients with and without urologic resection for low-grade appendiceal primary lesions (p = 0.23), high-grade appendiceal primary lesions (p = 0.40), or colorectal primary lesions (p = 0.14). Conclusions Urinary tract involvement in patients with peritoneal surface disease does not increase overall surgical morbidity. Patients with urologic procedures demonstrate survival patterns with meaningful prolongation of life. Urologic involvement should not be considered a contraindication for CRS/HIPEC in patients with resectable peritoneal surface disease. PMID:24217789

  18. Significance of urinary tract involvement in patients treated with cytoreductive surgery (CRS) and hyperthermic intraperitoneal chemotherapy (HIPEC).

    PubMed

    Votanopoulos, Konstantinos I; Randle, Reese W; Craven, Brandon; Swett, Katrina R; Levine, Edward A; Shen, Perry; Stewart, John H; Mirzazadeh, Majid

    2014-03-01

    Urinary tract involvement in patients with peritoneal surface disease treated with cytoreductive surgery (CRS) and hyperthermic intraperitoneal chemotherapy (HIPEC) often requires complex urologic resections and reconstruction to achieve optimal cytoreduction. The impact of these combined procedures on surgical outcomes is not well defined. A prospective database of CRS/HIPEC procedures was analyzed retrospectively. Type of malignancy, performance status, resection status, hospital and intensive care unit stay, morbidity, mortality, and overall survival were reviewed. A total of 864 patients underwent 933 CRS/HIPEC procedures, while 64 % (550) had preoperative ureteral stent placement. A total of 7.3 % had an additional urologic procedure without an increase in 30-day (p = 0.4) or 90-day (p = 1.0) mortality. Urologic procedures correlated with increased length of operating time (p < 0.001), blood loss (p < 0.001), and length of hospitalization (p = 0.003), yet were not associated with increased overall 30-day major morbidity (grade III/IV, p = 0.14). In multivariate analysis, independent predictors of additional urologic procedures were prior surgical score (p < 0.001), number of resected organs (p = 0.001), and low anterior resection (p = 0.03). Long-term survival was not statistically different between patients with and without urologic resection for low-grade appendiceal primary lesions (p = 0.23), high-grade appendiceal primary lesions (p = 0.40), or colorectal primary lesions (p = 0.14). Urinary tract involvement in patients with peritoneal surface disease does not increase overall surgical morbidity. Patients with urologic procedures demonstrate survival patterns with meaningful prolongation of life. Urologic involvement should not be considered a contraindication for CRS/HIPEC in patients with resectable peritoneal surface disease.

  19. Mini-STAR as bail-out strategy for percutaneous coronary intervention of chronic total occlusion.

    PubMed

    Galassi, Alfredo Ruggero; Tomasello, Salvatore Davide; Costanzo, Luca; Campisano, Maria Barbara; Barrano, Giombattista; Ueno, Masafumi; Tello-Montoliu, Antonio; Tamburino, Corrado

    2012-01-01

    Although the advancement of the equipment and the presence of innovative techniques, percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) continues to be affected by lower procedural success in comparison with non occluded vessel PCI. We describe a new technique for the treatment of coronary CTO which utilizes a new generation of polymeric wires. From March 2009 to June 2010 different strategies were adopted as "bail out" after an initial attempt failed in 117 consecutive CTO lesions. Among these, conventional strategies (CS) such as parallel wire, sub-intimal tracking and re-entry (STAR), microchannel technique, intracoronary ultrasound guided revascularization and anchor balloon, were used in 75 cases (64.1%), while in the remaining a new technique, the "mini-STAR," was used (39.9%). Although no substantial differences were observed regarding the distribution of clinical features and angiographic lesions characteristics between the populations, mini-STAR was able to achieve a higher rate of procedural success in comparison with other CS (97.6% vs. 52%, P < 0.001) with lower contrast agent use (442 ± 259 cm(3) vs. 561 ± 243 cm(3), P = 0.01) and shorter procedural and fluoroscopy times (122 ± 61 vs. 157 ± 74 min, P = 0.009 and 60 ± 31 min vs. 75 ± 38 min, P = 0.03, respectively). No differences were observed in term of peri-procedural complications such as procedural myocardial infarction, coronary perforations, and contrast-induced nephropathy between mini-STAR and CS. The mini-STAR technique is a promising strategy for the treatment of CTO lesions, achieving a high procedural success rate and low occurrence of procedural adverse events. Copyright © 2011 Wiley Periodicals, Inc.

  20. Accuracy of using Diagnosis Procedure Combination administrative claims data for estimating the amount of opioid consumption among cancer patients in Japan.

    PubMed

    Iwamoto, Momoko; Higashi, Takahiro; Miura, Hiroki; Kawaguchi, Takahiro; Tanaka, Shigeyuki; Yamashita, Itsuku; Yoshimoto, Tetsusuke; Yoshida, Shigeaki; Matoba, Motohiro

    2015-11-01

    The state of opioid consumption among cancer patients has never been comprehensively investigated in Japan. The Diagnosis Procedure Combination claims data may be used to measure and monitor opioid consumption among cancer patients, but the accuracy of using the Diagnosis Procedure Combination data for this purpose has never been tested. We aimed to ascertain the accuracy of using the Diagnosis Procedure Combination claims data for estimating total opioid analgesic consumption by cancer patients compared with electronic medical records at Aomori Prefectural Central Hospital. We calculated percent differences between estimates obtained from electronic medical records and Diagnosis Procedure Combination claims data by month and drug type (morphine, oxycodone, fentanyl, buprenorphine, codeine and tramadol) between 1 October 2012 and 30 September 2013, and further examined the causes of discrepancy by reviewing medical and administrative charts between April and July 2013. Percent differences varied by month for drug types with small prescription volumes, but less so for drugs with larger prescription volumes. Differences also tended to diminish when consumption was compared for a year instead of a month. Total percent difference between electronic medical records and Diagnosis Procedure Combination data during the study period was -0.1% (4721 mg per year per hospital), as electronic medical records as baseline. Half of the discrepancy was caused by errors in data entry. Our study showed that Diagnosis Procedure Combination claims data can be used to accurately estimate opioid consumption among a population of cancer patients, although the same conclusion cannot be made for individual estimates or when making estimates for a group of patients over a short period of time. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Opened Proton Pump Inhibitor Capsules Reduce Time to Healing Compared With Intact Capsules for Marginal Ulceration Following Roux-en-Y Gastric Bypass.

    PubMed

    Schulman, Allison R; Chan, Walter W; Devery, Aiofe; Ryan, Michele B; Thompson, Christopher C

    2017-04-01

    Marginal ulceration, or ulceration at the gastrojejunal anastomosis, is a common complication of Roux-en-Y gastric bypass (RYGB). Acidity likely contributes to the pathophysiology, and proton pump inhibitors (PPIs) frequently are prescribed for treatment. However, patients with gastric bypass only have a small gastric pouch and rapid small-bowel transit, which limits the opportunity for capsule breakdown and PPI absorption. Soluble PPIs (open capsules [OCs]) might be absorbed more easily than intact capsules (ICs). We compared time to ulcer healing, number of endoscopic procedures, and use of health care for patients with marginal ulceration who received PPIs in OC vs IC form. We performed a retrospective study of 164 patients diagnosed with marginal ulceration who underwent RYGB at the Brigham and Women's Hospital from 2000 through 2015. Patients received high-dose PPIs and underwent repeat endoscopy every 3 months until ulcer healing was confirmed. We used time-to-event analysis with a Cox proportional hazards model to evaluate the association between mode of PPI administration and time to ulcer healing, in addition to Cox multivariate regression analysis. Total charge (procedural and maintenance) was determined by comparison of categorized charges incurred from time of ulcer diagnosis to resolution. The primary outcome was time to healing of marginal ulceration in RYGB patients receiving high-dose PPIs in OC vs IC form. A total of 162 patients were included (115 received OC and 49 received IC). All patients were followed up until ulcer healing was confirmed. The median time to ulcer healing was 91.0 days for the OC group vs 342.0 days for the IC group (P < .001). OC was the only independent predictor of time to ulcer healing (P < .001) when we controlled for known risk factors. The number of endoscopic procedures (P = .02) and overall health care utilization (P = .05) were lower in the OC than the IC group. Patients with marginal ulceration after RYGB who receive OC PPIs have shorter ulcer healing times, fewer endoscopic procedures, and use less health care resources compared with patients who receive IC PPIs. Given these results and the high prevalence of marginal ulceration in this patient population, the use of OC PPIs is a low-risk, low-cost alternative that should be considered. Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.

  2. Does intraoperative fluid management in spine surgery predict intensive care unit length of stay?

    PubMed

    Nahtomi-Shick, O; Kostuik, J P; Winters, B D; Breder, C D; Sieber, A N; Sieber, F E

    2001-05-01

    To determine whether intraoperative fluid management in spine surgery predicts postoperative intensive care unit length of stay (ICU LOS). Retrospective case series. University-affiliated medical center. 103 adult ASA physical status I, II, and III patients undergoing spine surgery. Patients were divided into three LOS groups: no ICU stay (LOS0) (n = 26), 1 day ICU stay (LOS1) (n = 48), and ICU stay > 1 day (LOS2) (n = 29). Measurements were analyzed by groups using the Kruskal-Wallis and Mann-Whitney tests, and linear regression. Demographics, comorbidity, length of surgery, surgical procedure, and intraoperative fluids were recorded. The important differences in perioperative fluid management among the three groups included estimated blood loss (612 +/- 480 mL, 1853 +/- 1175 mL, 2702 +/- 1771 mL, means +/- SD); total crystalloid administration (2715 +/- 1396 mL, 5717 +/- 2574 mL, 7281 +/- 3417 mL); and total blood administration (92 +/- 279 mL, 935 +/- 757 mL, 1542 +/- 1230 mL) in LOS0, LOS1, and LOS2, respectively. The mixture of surgical procedures was similar in LOS1 and LOS2; and differed from LOS0. Predictors of ICU LOS included age, ASA physical status, surgical procedure, total crystalloid administration, and platelet administration. Surgical procedure and total crystalloid administration correlated (Pearson correlation coefficient = 0.441; p = 0.000) and were not related to age or ASA physical status. Total crystalloid administration during spine surgery does predict ICU LOS. In addition, total crystalloid administration is closely related to the surgical procedure. Given that the mixture of surgical procedures was similar in LOS1 and LOS2, but differed in estimated blood loss, total crystalloid administration, and total blood administration; intraoperative fluid management during spine surgery only predicts ICU LOS insofar as total crystalloid administration is related to the surgical procedure.

  3. Sensitive Procedures for Determining the Permeation Resistance of Chlorinated Polyethylene Against Liquid Propellants

    NASA Technical Reports Server (NTRS)

    Waller, Jess M.; Williams, James H.; Fries, Joseph (Technical Monitor)

    1999-01-01

    The permeation resistance of chlorinated polyethylene (CPE) used in totally encapsulating chemical protective suits against the aerospace fuels hydrazine, monomethylhydrazine, and uns-dimethylhydrazine was determined by measuring the breakthrough time (BT) and time-averaged vapor transmission rate (VTR) using procedures consistent with ASTM F 739 and ASTM F 1383. Two exposure scenarios were simulated: a 2 hour (h) fuel vapor exposure, and a liquid fuel "splash" followed by a 2 h vapor exposure. To simulate internal suit pressure during operation, a positive differential pressure of 0.3 in. water (75 Pa) on the collection side of the permeation apparatus was used. Using the available data, a model was developed to estimate propellant concentrations inside an air-line fed, totally encapsulating chemical protective suit. Concentrations were calculated under simulated conditions of fixed vapor transmission rate, variable breathing air flow rate, and variable splash exposure area. Calculations showed that the maximum allowable permeation rates of hydrazine fuels through CPE were of the order of 0.05 to 0.08 ng/sq cm min for encapsulating suits with low breathing air flow rates (of the order of 5 scfm or 140 L min-1). Above these permeation rates, the 10 parts-per-billion (ppb) threshold limit value time-weighted average could be exceeded. To evaluate suit performance at 10 ppb threshold-limiting value/time-weighted average level concentrations, use of a sensitive analytical method such as cation exchange high performance liquid chromatography with amperometric detection was found to be essential. The analytical detection limit determines the lowest measurable VTR, which in turn governed the lowest per meant concentration that could be calculated inside the totally encapsulating chemical protective suit.

  4. Butorphanol, azaperone, and medetomidine anesthesia in free-ranging white-tailed deer (Odocoileus virginianus) using radiotransmitter darts.

    PubMed

    Siegal-Willott, Jessica; Citino, Scott B; Wade, Scotty; Elder, Laura; Hayek, Lee-Ann C; Lance, William R

    2009-04-01

    Fourteen free-ranging white-tailed deer (Odocoileus virginianus) were successfully anesthetized for a total of 15 anesthetic events using a combination of butorphanol (mean+/-SD, 0.58+/-0.1 mg/kg), azaperone (0.37+/-0.06 mg/kg), and medetomidine (0.19+/-0.03 mg/kg) (BAM) administered by radiotelemetry darts from hunting blinds between November 2006 and May 2007. Mean time to locate deer (mean+/-SD, 17. 3+/-7 min), to recumbency (21.4+/-5 min), to initiation of data acquisition (27.5+/-8 min), total down time (37+/-6 min), and average distance run (161+/-82 m) were recorded. Physiologic monitoring was done every 5 min for a total of 20 min. Arterial blood gases were collected every 10 min. Mild to moderate hypoxemia and mildly depressed ventilation occurred in some animals. Muscle relaxation and plane of anesthesia were adequate for completion of all procedures; two deer were administered intravenous butorphanol supplementation to achieve light anesthesia (mean+/-SD, 0.19 mg/kg; 0.12 mg/kg). Recovery following intramuscular administration of naltrexone (1.34+/-0.42 mg/kg; 2x butorphanol dose) and atipamezole (0.93+/-0.14 mg/kg; 5x medetomidine dose) was rapid, smooth, and complete. Mean+/-SD recovery time was 4.5+/-1.5 min. Overall efficacy of the Pneu-Dart radiotelemetry system was 65%. Negative attributes of this protocol included long induction time and dart failure. No known mortalities occurred as a result of the study. This drug combination provided safe, reliable, short-term anesthesia of free-ranging white-tailed deer. Further evaluation for use in field procedures in other cervids is warranted.

  5. Damage Control Orthopedics Management as Vital Procedure in Elderly Patients with Femoral Neck Fractures Complicated with Chronic Renal Failure: A Retrospective Cohort Study

    PubMed Central

    Dong, Chenhui; Wang, Yunjiao; Wang, Ziming; Wang, Yu; Wu, Siyu; Du, Quanyin; Wang, Aimin

    2016-01-01

    Background Chronic renal failure (CRF) predisposes to hip fractures in elderly patients, with high subsequent mortality. Selection and timing of the surgical procedure of such patients is a serious challenge. Many clinicians believe in earlier surgery as preferable and providing better outcomes. Damage control orthopedics (DCO) aids to adjust and optimize the overall condition of patients. Methods In 32 patients with femoral neck fractures complicated with CRF, we evaluated how the timing of the surgery determines the mortality rates if the DCO approach is applied. Preoperative ASA grading, POSSUM score, P-POSSUM score and DCO were carried out. Based on the assessment, timing of the surgery was ascertained. Results Of a total of 32 patients, twenty-nine patients were accepted for either early (< 48 hours; n = 18) or delayed (3–10 days; n = 10) surgery. Hip arthroplasty (total hip arthroplasty and hemiarthroplasty) was the principal surgery option. All patients survived operation and were followed up postoperatively with the average time of 30 days. Postoperative complications tended to occur at higher rates in the early vs. delayed surgery group (7/18 vs. 5/10). During follow up, a total of 3 patients died in both groups (2/18 in the early surgery and 1/10 in the delayed surgery group), mostly from multi-organ failures and acute respiratory distress syndrome. There was no significant difference in complication rates and Harris hip score between both groups. Conclusion In patients with femoral neck fracture complicated with CRF, delaying the surgery for several days does not increase the incidence of postoperative adverse events. PMID:27149117

  6. The role of robotic endovascular catheters in fenestrated stent grafting.

    PubMed

    Riga, Celia V; Cheshire, Nicholas J W; Hamady, Mohamad S; Bicknell, Colin D

    2010-04-01

    Fenestrated stent grafting has allowed the treatment of complex thoraco-abdominal aneurysm disease via a totally endovascular approach, but the procedure can be technically challenging and time consuming. We investigated whether this procedure may be enhanced by remotely steerable robotic endovascular catheters. A four-vessel fenestrated stent graft partially deployed within a computed tomography (CT)-reconstructed pulsatile thoraco-abdominal aneurysm silicon model was used. Fifteen operators were recruited to participate in the study and divided into three groups, based on their endovascular experience: group A (n = 4, 100-200 endovascular procedures, group B (n = 5, 200-300), and group C (n = 6, >300). All operators were asked to cannulate the renal and visceral vessels under fluoroscopic guidance, using conventional and robotic techniques. Quantitative (catheterization times and wire/catheter tip movements) and qualitative metrics (procedure-specific-rating scale [IC3ST]), which grades operators on catheter use, instrumentation, successful cannulation/catheterization, and overall performance were compared. Median procedure time for cannulation of all four vessels was reduced using the robotic system (2.87 min, interquartile range [IQR; 2.20-3.90] versus 17.24 min [11.90-19.80]; P < .001) for each individual operator, regardless of the level of endovascular experience. The total number of wire/catheter movements taken to complete the task was also significantly reduced (38, IQR [29-57] versus 454 [283-687]; P < .001). There were significant differences in time and movement for cannulation of each individual vessel in the phantom. Robotic catheter operator radiation exposure was negligible as the robotic workstation is remote and away from the radiation source. Overall performance scores significantly improved using the robotic system, despite minimal operator exposure to this technology (IC3ST score 29/35, IQR [22.8-30.7] versus 19/35 [13-24.3]; P = .002). Each group of operators demonstrated an improvement in performance with robotic cannulation. For group A, median IC3ST score was 28/35, IQR (22-33) versus 15/35 (11-20); P = .04; for group B, 30/35 (27-31) versus 19/35 (18-24); P = .07; and for group C, 28.8/35 (28.5-29) versus 22/35 (16-24); P = .06. For groups B and C, these differences did not reach statistical significance. Robotic catheterization of target vessels during this procedure is feasible and minimizes radiation exposure for the operator. Steerable robotic catheters with intuitive control may overcome some of the limitations of standard catheter technology, enhance target vessel cannulation, reduce instrumentation, and improve overall performance scores.

  7. Radiation exposure of the anesthesiologist in the neurointerventional suite.

    PubMed

    Anastasian, Zirka H; Strozyk, Dorothea; Meyers, Philip M; Wang, Shuang; Berman, Mitchell F

    2011-03-01

    Scatter radiation during interventional radiology procedures can produce cataracts in participating medical personnel. Standard safety equipment for the radiologist includes eye protection. The typical configuration of fluoroscopy equipment directs radiation scatter away from the radiologist and toward the anesthesiologist. This study analyzed facial radiation exposure of the anesthesiologist during interventional neuroradiology procedures. Radiation exposure to the forehead of the anesthesiologist and radiologist was measured during 31 adult neuroradiologic procedures involving the head or neck. Variables hypothesized to affect anesthesiologist exposure were recorded for each procedure. These included total radiation emitted by fluoroscopic equipment, radiologist exposure, number of pharmacologic interventions performed by the anesthesiologist, and other variables. Radiation exposure to the anesthesiologist's face averaged 6.5 ± 5.4 μSv per interventional procedure. This exposure was more than 6-fold greater (P < 0.0005) than for noninterventional angiographic procedures (1.0 ± 1.0) and averaged more than 3-fold the exposure of the radiologist (ratio, 3.2; 95% CI, 1.8-4.5). Multiple linear regression analysis showed that the exposure of the anesthesiologist was correlated with the number of pharmacologic interventions performed by the anesthesiologist and the total exposure of the radiologist. Current guidelines for occupational radiation exposure to the eye are undergoing review and are likely to be lowered below the current 100-150 mSv/yr limit. Anesthesiologists who spend significant time in neurointerventional radiology suites may have ocular radiation exposure approaching that of a radiologist. To ensure parity with safety standards adopted by radiologists, these anesthesiologists should wear protective eyewear.

  8. Detection of intensity bursts using Hawkes processes: An application to high-frequency financial data

    NASA Astrophysics Data System (ADS)

    Rambaldi, Marcello; Filimonov, Vladimir; Lillo, Fabrizio

    2018-03-01

    Given a stationary point process, an intensity burst is defined as a short time period during which the number of counts is larger than the typical count rate. It might signal a local nonstationarity or the presence of an external perturbation to the system. In this paper we propose a procedure for the detection of intensity bursts within the Hawkes process framework. By using a model selection scheme we show that our procedure can be used to detect intensity bursts when both their occurrence time and their total number is unknown. Moreover, the initial time of the burst can be determined with a precision given by the typical interevent time. We apply our methodology to the midprice change in foreign exchange (FX) markets showing that these bursts are frequent and that only a relatively small fraction is associated with news arrival. We show lead-lag relations in intensity burst occurrence across different FX rates and we discuss their relation with price jumps.

  9. Surgeon specialization and operative mortality in United States: retrospective analysis

    PubMed Central

    Dalton, Maurice; Cutler, David M; Birkmeyer, John D; Chandra, Amitabh

    2016-01-01

    Objective To measure the association between a surgeon’s degree of specialization in a specific procedure and patient mortality. Design Retrospective analysis of Medicare data. Setting US patients aged 66 or older enrolled in traditional fee for service Medicare. Participants 25 152 US surgeons who performed one of eight procedures (carotid endarterectomy, coronary artery bypass grafting, valve replacement, abdominal aortic aneurysm repair, lung resection, cystectomy, pancreatic resection, or esophagectomy) on 695 987 patients in 2008-13. Main outcome measure Relative risk reduction in risk adjusted and volume adjusted 30 day operative mortality between surgeons in the bottom quarter and top quarter of surgeon specialization (defined as the number of times the surgeon performed the specific procedure divided by his/her total operative volume across all procedures). Results For all four cardiovascular procedures and two out of four cancer resections, a surgeon’s degree of specialization was a significant predictor of operative mortality independent of the number of times he or she performed that procedure: carotid endarterectomy (relative risk reduction between bottom and top quarter of surgeons 28%, 95% confidence interval 0% to 48%); coronary artery bypass grafting (15%, 4% to 25%); valve replacement (46%, 37% to 53%); abdominal aortic aneurysm repair (42%, 29% to 53%); lung resection (28%, 5% to 46%); and cystectomy (41%, 8% to 63%). In five procedures (carotid endarterectomy, valve replacement, lung resection, cystectomy, and esophagectomy), the relative risk reduction from surgeon specialization was greater than that from surgeon volume for that specific procedure. Furthermore, surgeon specialization accounted for 9% (coronary artery bypass grafting) to 100% (cystectomy) of the relative risk reduction otherwise attributable to volume in that specific procedure. Conclusion For several common procedures, surgeon specialization was an important predictor of operative mortality independent of volume in that specific procedure. When selecting a surgeon, patients, referring physicians, and administrators assigning operative workload may want to consider a surgeon’s procedure specific volume as well as the degree to which a surgeon specializes in that procedure. PMID:27444190

  10. [The conversion of a modified Fontan procedure to a total extracardiac cavo-pulmonary conduit. The Medico-Surgical Cardiology Group].

    PubMed

    Abella, R F; Marianeschi, S M; De la Torre, T; Smedile, G; Masetti, P; Cipriani, A; Magherini, A; Meli, M; Iorio, F S; Marcelletti, C F

    1998-06-01

    After a modified Fontan procedure with atriopulmonary or atrioventricular conduit, some patients present stress intolerance, supraventricular arrhythmia, recurrent pleuropericardial or ascitic effusions, and protein-losing enteropathy, all of which are signs that the previous procedure has failed. The aim of this study was to evaluate the midterm outcome after surgical therapy for this condition. Between August 1994 and December 1997, nine patients (6 males and 3 females), age 10 to 39 (mean 21.5) years, underwent conversion of previous modified Fontan procedure to total extracardiac cavo-pulmonary connection. Time from the previous procedure was 6 to 18 years (mean 10). Diagnosis was tricuspid atresia with pulmonary stenosis (n = 2), double-inlet left ventricle and concordant ventriculoarterial connection (n = 3), double-inlet left ventricle and discordant ventriculoarterial connection (n = 3), Holmes heart (n = 1). Nine patients presented decreased stress tolerance, seven had arrhythmia, five had pleuropericardial effusions and two had protein-losing enteropathy. In all but one patient, right atrial pressure was higher than 15 mmHg, while in six patients the cardiac index was less than 2 l/min/m2. A polytetrafluoroethylene non-valved conduit was interposed between the inferior vena cava and the right pulmonary artery for conversion in all patients. A bidirectional cavo-pulmonary anastomosis (modified Glenn) was associated in all patients. Evaluation was done by NYHA Class and by an arbitrary score assigned to patients based on 7 parameters. There was no perioperative mortality. All patients were clinically improved at a mean follow-up of 24 months (range: 3 to 46). No patient had effusions, and the arrhythmias disappeared in 4 patients and were controlled by medical therapy in one. The two patients with protein-losing enteropathy improved markedly within 30 days and the score dropped below 10 points. The conversion of the modified Fontan procedure to total extracardiac cavo-pulmonary connection improves clinical condition by decreasing the right atrium-pulmonary gradient and right atrial preload, and by providing a laminar cavo-pulmonary flow without any need for intracardiac anastomoses. This procedure should be undertaken early in this subset of patients, before ventricular failure ensues.

  11. The incidence of secondary hernias diagnosed during laparoscopic total extraperitoneal inguinal herniorrhaphy.

    PubMed

    Woodward, A M; Choe, E U; Flint, L M; Ferrara, J J

    1998-02-01

    During a 24-month period beginning in July of 1995, laparoscopic total extraperitoneal inguinal herniorrhaphy was attempted in 53 patients. All procedures were performed at a single institution, by senior-level general surgery residents, with the same attending surgeon functioning as first assistant. Three patients required conversion to an "open" procedure (all had a prior history of herniorrhaphy or lower abdominal surgery), leaving 50 patients for analysis. Preoperatively, a unilateral hernia was evident on clinical grounds in 29 patients, the remaining 21 presenting with signs of a bilateral hernia; of the total, 11 had a history of prior hernia repair on the presently affected side. At surgery, a total of 115 hernia defects (indirect, direct, femoral) were identified, 38% of which were discovered only at the time of surgery. Sixty-four percent of patients were found to have at least one of these "secondary" hernias. After reduction of the hernia(s), all defects were covered with polypropylene mesh secured with spiral tacks. There were 10 perioperative complications, one of which required corrective surgical intervention. Over 70% of patients were discharged on the day of surgery; 92% returned home within 23 h of their operation. The most common reason for delay of hospital discharge was urinary retention. There have been no recurrences in short-term follow-up. Most patients were pleased with the recovery time from and the cosmetic results of their surgery. These results suggest that laparoscopic total extraperitoneal herniorrhaphy represents a safe, effective, cosmetically appealing alternative to open hernia repair. Moreover, this approach may provide an added advantage insofar as identifying additional hernia defects that, when repaired, may ultimately yield a lower recurrence rate than might otherwise have been expected.

  12. Administration order of midazolam/fentanyl for moderate dental sedation.

    PubMed

    Lobb, Douglas; Clarke, Alix; Lai, Hollis

    2018-02-01

    The purpose of this study is to investigate the effects of administration order when a sedative drug (midazolam) and an opioid analgesic drug (fentanyl) is applied for moderate intravenous (IV) sedation in dentistry. A retrospective chart review was conducted in one dental clinic during its transition from a midazolam-first to a fentanyl-first protocol for dental procedures requiring moderate IV sedation. Physiological parameters, drug administration times, patient recovery times, drug dosages, and patient recall and satisfaction were investigated for differences. A total of 76 charts (40 midazolam-first and 36 fentanyl-first administrations), were used in the analysis. Administering midazolam first resulted in an average 4.38 min (52%) decrease in administration times (P < 0.001), and a decrease in procedural recollection immediately following the procedure (P = 0.03), and 24 to 48 hours later (P = 0.009). Administering fentanyl first required an average of 2.43 mg (29%) less midazolam (P < 0.001). No significant differences were found for change in vital signs, minimum oxygen saturation levels, recovery times, and patient satisfaction (P > 0.05). Oxygen saturation levels did not drop below 90% for either group; however, 5 cases in the fentanyl-first group fell to between 90% and 92%, compared with 0 cases in the midazolam-first group. The administration order of fentanyl and midazolam may have different effects on patients and the sedation procedure. Findings from this study should be used to facilitate discussion among dental practitioners and to guide additional research investigating this topic.

  13. Totally extraperitoneal (TEP) bilateral hernioplasty using the Single Site® robotic da Vinci platform (DV-SS TEP): description of the technique and preliminary results.

    PubMed

    Cestari, A; Galli, A C; Sangalli, M N; Zanoni, M; Ferrari, M; Roviaro, G

    2017-06-01

    Laparoendoscopic single site totally extraperitoneal (TEP) hernia repair showed to be a feasible alternative to conventional laparoscopic hernia repair; nevertheless single site surgery, with the loss of instruments triangulation can be a demanding procedure. To overcome those hurdles, the Single Site® (SS) platform of the da Vinci (DV) Si robotic system enables to perform surgical procedures through a 25-mm skin incision, with a stable 3D vision and restoring an adequate triangulation of the surgical instruments. We present in details the technique and the preliminary results of DV-SS TEP, to our knowledge the first cases reported in literature. In March 2016, three consecutive male patients (mean age 46.6 years-mean BMI 25.3) with bilateral symptomatic inguinal hernia were submitted to DV-SS TEP in our institutions. Feasibility, codification of the technique, operative time and perioperative outcomes were recorded. All the procedures were completed as scheduled, with no conversion to other techniques. Mean operative time was 98.6 min, ranging between 155 and 55 min, reflecting the learning curve of the operating room team on this new procedure. No intraoperative or postoperative complications were experienced and all the patients were discharged within 24 h after surgery. Patients reported satisfactory postoperative course, with no recurrence of inguinal hernia and satisfaction in cosmetic result at 6-month follow-up. DV-SS TEP inguinal hernia repair showed to be feasible and effective surgical option for bilateral groin hernia repair. Patients' outcome was uneventful, with optimal cosmetic results. Further studies comparing this innovative technique to TEP or LESS TEP should be promoted.

  14. Comparison of Spectra Optia and COBE Spectra apheresis systems' performances for red blood cell exchange procedures.

    PubMed

    Kim, Jaehyup; Joseph, Ranjit; Matevosyan, Karen; Sarode, Ravi

    2016-12-01

    Spectra Optia (Terumo BCT, Lakewood, CO) was FDA approved for red blood cell exchange (RBCx) procedures in January 2014 and is expected to replace COBE spectra (Terumo BCT) very soon in the USA. The performance characteristics of these devices for Isovolemic Hemodilution (IHD-RBCx) procedure were compared in this study. A total of 114 IHD-RBCx procedures from 19 patients were analyzed. For every patient, three procedures on each device with similar pre-procedure hematocrits were compared. Pre and post procedure laboratory parameters compared were hemoglobin S (HbS), hematocrits (Hct), platelet counts and fraction of cells remaining (FCR). Statistical analysis was performed using t-test adjusted by the Holm-Bonferroni method to reduce family-wise error rate. There were no significant differences between these two devices in regards to HbS, Hct, FCR and platelet counts (p = > 0.05). However, rinseback volume (124.2 ± 8.9 ml) and normal saline replacement volume during IHD phase (296.1 ± 97.2 ml) were lower in Spectra Optia as compared to COBE Spectra (337 ± 33.8 ml and 326.6 ± 105.2 ml, p value <0.001 and 0.030 respectively). Spectra Optia had a longer run time (107.1 ± 15.9 min vs 123.8 ± 19.6 min, p value <0.001) overall. Performance characteristics of Spectra Optia for HbS, Hct and FCR were similar to COBE Spectra for IHD-RBCx. IHD-RBCx procedure on Optia required less normal saline replacement volume and rinse back volume but with overall longer procedure run time. Copyright © 2016. Published by Elsevier Ltd.

  15. Improving education: just-in-time splinting video.

    PubMed

    Wang, Vincent; Cheng, Yu-Tsun; Liu, Deborah

    2016-06-01

    Just-in-time training (JITT) is an emerging concept in medical procedural education, but with few studies to support its routine use. Providing a brief educational intervention in the form of a digital video immediately prior to patient care may be an effective method to reteach knowledge for procedural techniques learned previously. Paediatric resident physicians were taught to perform a volar splint in a small workshop setting. Subsequently, they were asked to demonstrate their splinting proficiency by performing a splint on another doctor. Proficiency was scored on a five-point assessment tool. After 2-12 months, participants were asked to demonstrate their splinting proficiency on one of the investigators, and were divided into the control group (no further instruction) and the intervention group, which viewed a 3-minute JITT digital video demonstrating the splinting technique prior to performing the procedure. Thirty subjects were enrolled between August 2012 and July 2013, and 29 of 30 completed the study. The retest splinting time was not significantly different, but if the JITT group included watching the video, the total time difference was statistically significant: 3.86 minutes (control) versus 7.07 minutes (JITT) (95% confidence interval: 2.20-3.90 minutes). The average assessment score difference was 1.87 points higher for the JITT group, which was a statistically significant difference (95% confidence interval: 1.00-3.00). Just-in-time training is an emerging concept in medical procedural education JITT seems to be an effective tool in medical education for reinforcing previously learned skills. JITT may offer other possibilities for enhancing medical education. © 2015 John Wiley & Sons Ltd.

  16. Tooth loss in 1535 treated periodontal patients.

    PubMed

    Nabers, C L; Stalker, W H; Esparza, D; Naylor, B; Canales, S

    1988-05-01

    Of 1535 treated recall patients surveyed over an average time of 12.9 years since treatment was completed, 1371 had lost no teeth from periodontal disease. The total number of teeth lost was 444, with the average tooth loss for the 1535 patients being 0.29. In the three full arch splinted cases, the loss rate was 14.67 teeth per patient. Patients treated without any excisional or flap surgical procedures made up 26.5% of those surveyed, whereas 73.5% had required various surgical procedures. No attempt was made to compare different pocket therapy procedures. Although many patients developed recurrent periodontal problems during recall, only 15.9% of the 1535 patients required surgical retreatment. Teeth that were originally given a doubtful prognosis often were responsible for recurrent problems and sometimes required extraction.

  17. The use of piezosurgery in cranial surgery in children.

    PubMed

    Ramieri, Valerio; Saponaro, Gianmarco; Lenzi, Jacopo; Caporlingua, Federico; Polimeni, Antonella; Silvestri, Alessandro; Pizzuti, Antonio; Roggini, Mario; Tarani, Luigi; Papoff, Paola; Giancotti, Antonella; Castori, Marco; Manganaro, Lucia; Cascone, Piero; Piero, Cascone

    2015-05-01

    Piezosurgery is an alternative surgical technique, now widely tested, that uses ultrasounds for bone cutting. This device uses ultrasounds to section hard tissues without harming surrounding soft tissues. The authors analyzed their experience in craniomaxillofacial procedures with piezosurgery. A comparison between operation timing and complication rates between piezosurgery and traditional cutting instruments has been performed. A total of 27 patients were examined (15 females and 12 males; average age, of 5.5 months) affected by craniosynostosis. The aim of this study was to analyze the advantages and disadvantages of piezosurgery in pediatric craniofacial procedures. Piezoelectric device in this study has shown being a valid instrument for bone cutting in accurate procedures, because it allows performing a more precise and safer cutting, without the risk of harming surrounding tissues.

  18. The Feasibility of Real-Time Intraoperative Performance Assessment With SIMPL (System for Improving and Measuring Procedural Learning): Early Experience From a Multi-institutional Trial.

    PubMed

    Bohnen, Jordan D; George, Brian C; Williams, Reed G; Schuller, Mary C; DaRosa, Debra A; Torbeck, Laura; Mullen, John T; Meyerson, Shari L; Auyang, Edward D; Chipman, Jeffrey G; Choi, Jennifer N; Choti, Michael A; Endean, Eric D; Foley, Eugene F; Mandell, Samuel P; Meier, Andreas H; Smink, Douglas S; Terhune, Kyla P; Wise, Paul E; Soper, Nathaniel J; Zwischenberger, Joseph B; Lillemoe, Keith D; Dunnington, Gary L; Fryer, Jonathan P

    Intraoperative performance assessment of residents is of growing interest to trainees, faculty, and accreditors. Current approaches to collect such assessments are limited by low participation rates and long delays between procedure and evaluation. We deployed an innovative, smartphone-based tool, SIMPL (System for Improving and Measuring Procedural Learning), to make real-time intraoperative performance assessment feasible for every case in which surgical trainees participate, and hypothesized that SIMPL could be feasibly integrated into surgical training programs. Between September 1, 2015 and February 29, 2016, 15 U.S. general surgery residency programs were enrolled in an institutional review board-approved trial. SIMPL was made available after 70% of faculty and residents completed a 1-hour training session. Descriptive and univariate statistics analyzed multiple dimensions of feasibility, including training rates, volume of assessments, response rates/times, and dictation rates. The 20 most active residents and attendings were evaluated in greater detail. A total of 90% of eligible users (1267/1412) completed training. Further, 13/15 programs began using SIMPL. Totally, 6024 assessments were completed by 254 categorical general surgery residents (n = 3555 assessments) and 259 attendings (n = 2469 assessments), and 3762 unique operations were assessed. There was significant heterogeneity in participation within and between programs. Mean percentage (range) of users who completed ≥1, 5, and 20 assessments were 62% (21%-96%), 34% (5%-75%), and 10% (0%-32%) across all programs, and 96%, 75%, and 32% in the most active program. Overall, response rate was 70%, dictation rate was 24%, and mean response time was 12 hours. Assessments increased from 357 (September 2015) to 1146 (February 2016). The 20 most active residents each received mean 46 assessments by 10 attendings for 20 different procedures. SIMPL can be feasibly integrated into surgical training programs to enhance the frequency and timeliness of intraoperative performance assessment. We believe SIMPL could help facilitate a national competency-based surgical training system, although local and systemic challenges still need to be addressed. Copyright © 2016. Published by Elsevier Inc.

  19. Radiation dosage during pediatric diagnostic or interventional cardiac catheterizations using the “air gap technique” and an aggressive “as low as reasonably achievable” radiation reduction protocol in patients weighing <20 kg

    PubMed Central

    Osei, Frank A; Hayman, Joshua; Sutton, Nicole J; Pass, Robert H

    2016-01-01

    Background: Cardiac catheterizations expose both the patient and staff to the risks of ionizing radiation. Studies using the “air gap” technique (AGT) in various radiological procedures indicate that its use leads to reduction in radiation exposure but there are no data on its use for pediatric cardiac catheterization. The aim of this study was to retrospectively review the radiation exposure data for children weighing <20 kg during cardiac catheterizations using AGT and an “as low as reasonably achievable (ALARA)” radiation reduction protocol. Patients and Methods: All patients weighing <20 kg who underwent cardiac catheterization at the Children's Hospital at Montefiore (CHAM), New York, the United States from 05/2011 to 10/2013 were included. Transplant patients who underwent routine endomyocardial biopsy and those who had surgical procedures at the time of the catheterizations were excluded. The ALARA protocol was used in concert with AGT with the flat panel detector positioned 110 cm from the patient. Demographics, procedural data, and patient radiation exposure levels were collected and analyzed. Results: One-hundred and twenty-seven patients underwent 151 procedures within the study period. The median age was 1.2 years (range: 1 day to 7.9 years) and median weight was 8.8 kg (range: 1.9-19.7). Eighty-nine (59%) of the procedures were interventional. The median total fluoro time was 13 min [interquartile range (IQR) 7.3-21.8]. The median total air Kerma (K) product was 55.6 mGy (IQR 17.6-94.2) and dose area product (DAP) was 189 Gym2 (IQR 62.6-425.5). Conclusion: Use of a novel ALARA and AGT protocol for cardiac catheterizations in children markedly reduced radiation exposure to levels far below recently reported values. Abbreviations: AGT: Air gap technique, ALARA: As low as reasonably achievable. PMID:27011686

  20. Practice patterns of academic general thoracic and adult cardiac surgeons.

    PubMed

    Ingram, Michael T; Wisner, David H; Cooke, David T

    2014-10-01

    We hypothesized that academic adult cardiac surgeons (CSs) and general thoracic surgeons (GTSs) would have distinct practice patterns of, not just case-mix, but also time devoted to outpatient care, involvement in critical care, and work relative value unit (wRVU) generation for the procedures they perform. We queried the University Health System Consortium-Association of American Medical Colleges Faculty Practice Solution Center database for fiscal years 2007-2008, 2008-2009, and 2009-2010 for the frequency of inpatient and outpatient current procedural terminology coding and wRVU data of academic GTSs and CSs. The Faculty Practice Solution Center database is a compilation of productivity and payer data from 86 academic institutions. The greatest wRVU generating current procedural terminology codes for CSs were, in order, coronary artery bypass grafting, aortic valve replacement, and mitral valve replacement. In contrast, open lobectomy, video-assisted thoracic surgery wedge, and video-assisted thoracic surgery lobectomy were greatest for GTSs. The 10 greatest wRVU-generating procedures for CSs generated more wRVUs than those for GTSs (P<.001). Although CSs generated significantly more hospital inpatient evaluation and management (E & M) wRVUs than did GTSs (P<.001), only 2.5% of the total wRVUs generated by CSs were from E & M codes versus 18.8% for GTSs. Critical care codes were 1.5% of total evaluation and management billing for both CSs and GTSs. Academic CSs and GTSs have distinct practice patterns. CSs receive greater reimbursement for services because of the greater wRVUs of the procedures performed compared with GTSs, and evaluation and management coding is a more important wRVU generator for GTSs. The results of our study could guide academic CS and GTS practice structure and time prioritization. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  1. French Immersion Programs Across Canada: The Influence of Cumulative Amounts of Time, Starting Age and Yearly Time Allotment on the Learning of French. A Review of Evaluations of French Immersion Programs. Research Report 81-12.

    ERIC Educational Resources Information Center

    MacNab, G. L.

    This paper reviews the results of research on various programs for learning French as a second language from kindergarten to grade 11 or 12 in selected Canadian school systems. Generally, it examines the effects of a number of factors on French learning, such as student selection procedures and student ability, starting age, total amount of time…

  2. Development of a Rational Design Procedure for Overland Flow Systems,

    DTIC Science & Technology

    1982-02-01

    to pre- report is based on reactor kinetics, a concept dict the hydraulic detention time. familiar to most environmental engineers. In the 2...Determine the removal kinetics for BOD, TSS, case of overland flow, the reactor is the soil surface NH3 -N and total P. where various physical, biological and...water along the top of each section, and a bed of down. The amount of time needed to reach hydraulic crushed stone placed beneath the pipe helped to

  3. Initial experience of using high field strength intraoperative MRI for neurosurgical procedures.

    PubMed

    Raheja, Amol; Tandon, Vivek; Suri, Ashish; Sarat Chandra, P; Kale, Shashank S; Garg, Ajay; Pandey, Ravindra M; Kalaivani, Mani; Mahapatra, Ashok K; Sharma, Bhawani S

    2015-08-01

    We report our initial experience to optimize neurosurgical procedures using high field strength intraoperative magnetic resonance imaging (IOMRI) in 300 consecutive patients as high field strength IOMRI rapidly becomes the standard of care for neurosurgical procedures. Three sequential groups (groups A, B, C; n=100 each) were compared with respect to time management, complications and technical difficulties to assess improvement in these parameters with experience. We observed a reduction in the number of technical difficulties (p<0.001), time to induction (p<0.001) and total anesthesia time (p=0.007) in sequential groups. IOMRI was performed for neuronavigation guidance (n=252) and intraoperative validation of extent of resection (EOR; n=67). Performing IOMRI increased the EOR over and beyond the primary surgical attempt in 20.5% (29/141) and 18% (11/61) of patients undergoing glioma and pituitary surgery, respectively. Overall, EOR improved in 59.7% of patients undergoing IOMRI (40/67). Intraoperative tractography and real time navigation using re-uploaded IOMRI images (accounting for brain shift) helps in intraoperative planning to reduce complications. IOMRI is an asset to neurosurgeons, helping to augment the EOR, especially in glioma and pituitary surgery, with no significant increase in morbidity to the patient. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Completely staple-free hand-sewn laparoscopic anastomosis in colorectal surgery.

    PubMed

    Lipski, David; Dapri, Giovanni; Himpens, Jacques

    2008-04-01

    Colonic continuity following a laparoscopic left hemicolectomy is usually performed by using a circular stapler to achieve end-to-end colorectal anastomosis. However, not much consideration is given to the costs of this technique and the long-term risk of stenosis. In this paper, we report the first case of a completely staple-free hand-sewn laparoscopic colonic anastomosis (CSHLCA) following a laparoscopic left hemicolectomy for cancer. Total operative time was 170 minutes, and the time to perform the anastomosis was 38 minutes. The postoperative stay was uneventful, with a total hospital stay of 6 days. CSHLCA is feasible and can lower the cost of the laparoscopic procedure. It may be considered in countries with limited access to mechanical staplers.

  5. Learning curve and early clinical outcomes for a robotic surgery novice performing robotic single site cholecystectomy.

    PubMed

    Angus, Andrew A; Sahi, Saad L; McIntosh, Bruce B

    2014-06-01

    A rapid training protocol has been developed for robotic surgery novices to learn robotic single-incision techniques. This study assesses the learning curve and early clinical results for a robotic surgery novice starting single-site cholecystectomy. A chart review was performed on the surgeon's first 55 patients to undergo this procedure. Average patient age was 46.01 ± 4.25 (range 21-86) years and BMI was 26.57 ± 4.25 (range 19.4-36.6) kg/m(2) . The mean port placement with docking time was 11.34 ± 3.74 (range 7-23) min. Mean console time was 28.74 ± 11.04 (range 15-66) min. Average total OR time was 61.84 ± 14.66 (range 40-105) min. All procedures were successfully completed without conversion or added ports. Complications included several minor procedural gall bladder perforations and miscellaneous postoperative symptomatic complaints. Robotic single site cholecystectomy can be safely performed by a robotic novice within a minimal learning curve and have early clinical results that are comparable to the published data of robotic experts. Copyright © 2013 John Wiley & Sons, Ltd.

  6. Women's experiences of participating in the early external cephalic version 2 trial.

    PubMed

    Murray-Davis, Beth; Marion, Anya; Malott, Anne; Reitsma, Angela; Hutton, Eileen K

    2012-03-01

    The international, multicenter External Cephalic Version 2 (ECV2) Trial compared early external cephalic version at 34(0/7) to 35(6/7) weeks with that at greater than 37 weeks. A total of 1,543 women were randomized from 68 centers in 21 countries. The goal of this component of the trial was to understand women's views about participation in a research trial and timing of external cephalic version. A postpartum questionnaire was completed containing a 5-point Likert scale examining contact and availability of staff, choice of timing of external cephalic version, preference of randomization, convenience of participating, and overall satisfaction. Participants also completed two open-ended questions related to timing of external cephalic version and satisfaction with the trial. Descriptive statistics and content analysis were used to analyze data. A total of 1,458 women completed the questionnaire, of whom 86 percent said "yes"-they would participate in the trial again. Themes influencing decisions about participating were perceptions of the external cephalic version experience, preferred mode of delivery, preferred timing of external cephalic version, and perceptions of the effectiveness of external cephalic version and of the trial environment. Many participants preferred the early timing of the procedure offered through the trial because of perceived advantages of a smaller baby being easier to turn and the opportunity for repeat procedures. Women were positive about their participation in the trial. Early external cephalic version was preferred over the traditional timing as it was perceived to afford both physiologic and practical advantages. © 2012, Copyright the Authors. Journal compilation © 2012, Wiley Periodicals, Inc.

  7. Experience and confidence of final year veterinary students in performing desexing surgeries.

    PubMed

    Gates, M C; Odom, T F; Sawicki, R K

    2018-07-01

    To describe the level of experience and confidence of veterinary students in performing canine and feline desexing procedures at the end of their final clinical year. A cross-sectional survey was conducted with veterinary students at Massey University in November 2017 after completion of their final clinical year. The questions included career plans after graduation, number of assisted and unassisted desexing procedures performed, approximate time to complete desexing surgeries, level of confidence with different aspects of desexing surgeries, what aspects of their desexing surgery training were most helpful, and what could be done to improve training in desexing surgical skills in veterinary school. The survey was completed by 70/95 (74%) students in their final clinical year. Among respondents, 55/70 (70%) had performed >2 unassisted feline neuters before graduation. However 38/70 (54%) students had never performed an unassisted feline spay, 31/70 (44%) had never performed an unassisted canine neuter, and 44/70 (63%) students had never performed an unassisted canine spay. The median reported times to complete a feline neuter, feline spay, canine neuter, and canine spay were 9, 40, 30 and 60 minutes, respectively. The median level of confidence for these procedures were 9, 6, 7 and 5 (on a scale from 1=least confident to 10=most confident), respectively. The reported time to complete procedures and the confidence in performing procedures did not change markedly with increasing total number of procedures performed. Students were most concerned about their ability to perform the desexing procedures in a reasonable amount of time and to prevent post-operative bleeding from occurring. Students were least concerned with their ability to manage post-operative pain in patients and to select the appropriate suture material. Free-text comments revealed that 62/70 (89%) students wanted more hands-on surgical experience prior to graduation. Many students are currently completing veterinary school with limited experience and low confidence with performing routine canine and feline desexing procedures. Further research is needed to identify the most effective ways for addressing this issue within the constraints of the veterinary curriculum and teaching hospital resources.

  8. Visual distraction alone for the improvement of colonoscopy-related pain and satisfaction

    PubMed Central

    Umezawa, Shotaro; Higurashi, Takuma; Uchiyama, Shiori; Sakai, Eiji; Ohkubo, Hidenori; Endo, Hiroki; Nonaka, Takashi; Nakajima, Atsushi

    2015-01-01

    AIM: To evaluate the effect of a relaxing visual distraction alone on patient pain, anxiety, and satisfaction during colonoscopy. METHODS: This study was designed as an endoscopist-blinded randomized controlled trial with 60 consecutively enrolled patients who underwent elective colonoscopy at Yokohama City University Hospital, Japan. Patients were randomly assigned to two groups: group 1 watched a silent movie using a head-mounted display, while group 2 only wore the display. All of the colonoscopies were performed without sedation. We examined pain, anxiety, and the satisfaction of patients before and after the procedure using questionnaires that included the Visual Analog Scale. Patients were also asked whether they would be willing to use the same method for a repeat procedure. RESULTS: A total of 60 patients were allocated to two groups. Two patients assigned to group 1 and one patient assigned to group 2 were excluded after the randomization. Twenty-eight patients in group 1 and 29 patients in group 2 were entered into the final analysis. The groups were similar in terms of gender, age, history of prior colonoscopy, and pre-procedural anxiety score. The two groups were comparable in terms of the cecal insertion rate, the time to reach the cecum, the time needed for the total procedure, and vital signs. The median anxiety score during the colonoscopy did not differ significantly between the two groups (median scores, 20 vs 24). The median pain score during the procedure was lower in group 1, but the difference was not significant (median scores, 24.5 vs 42). The patients in group 1 reported significantly higher median post-procedural satisfaction levels, compared with the patients in group 2 (median scores, 89 vs 72, P = 0.04). Nearly three-quarters of the patients in group 1 wished to use the same method for repeat procedures, and the difference in rates between the two groups was statistically significant (75.0% vs 48.3%, P = 0.04). Patients with greater levels of anxiety before the procedure tended to feel a painful sensation. Among patients with a pre-procedural anxiety score of 50 or higher, the anxiety score during the procedure was significantly lower in the group that received the visual distraction (median scores, 20 vs 68, P = 0.05); the pain score during the colonoscopy was also lower (median scores, 23 vs 57, P = 0.04). No adverse effects arising from the visual distraction were recognized. CONCLUSION: Visual distraction alone improves satisfaction in patients undergoing colonoscopy and decreases anxiety and pain during the procedure among patients with a high pre-procedural anxiety score. PMID:25914482

  9. Protection of quality and innovation in radiation oncology: the prospective multicenter trial the German Society of Radiation Oncology (DEGRO-QUIRO study). Evaluation of time, attendance of medical staff, and resources during radiotherapy with IMRT.

    PubMed

    Vorwerk, H; Zink, K; Schiller, R; Budach, V; Böhmer, D; Kampfer, S; Popp, W; Sack, H; Engenhart-Cabillic, R

    2014-05-01

    A number of national and international societies published recommendations regarding the required equipment and manpower assumed to be necessary to treat a number of patients with radiotherapy. None of these recommendations were based on actual time measurements needed for specific radiotherapy procedures. The German Society of Radiation Oncology (DEGRO) was interested in substantiating these recommendations by prospective evaluations of all important core procedures of radiotherapy in the most frequent cancers treated by radiotherapy. The results of the examinations of radiotherapy with intensity-modulated radiation therapy (IMRT) in patients with different tumor entities are presented in this manuscript. Four radiation therapy centers [University Hospital of Marburg, University Hospital of Giessen, University Hospital of Berlin (Charité), Klinikum rechts der Isar der Technischen Universität München] participated in this prospective study. The workload of the different occupational groups and room occupancies for the core procedures of radiotherapy were prospectively documented during a 2-month period per center and subsequently statistically analyzed. The time needed per patient varied considerably between individual patients and between centers for all the evaluated procedures. The technical preparation (contouring of target volume and organs at risk, treatment planning, and approval of treatment plan) was the most time-consuming process taking 3 h 54 min on average. The time taken by the medical physicists for this procedure amounted to about 57%. The training part of the preparation time was 87% of the measured time for the senior physician and resident. The total workload for all involved personnel comprised 74.9 min of manpower for the first treatment, 39.7 min for a routine treatment with image guidance, and 22.8 min without image guidance. The mean room occupancy varied between 10.6 min (routine treatment without image guidance) and 23.7 min (first treatment with image guidance). The prospective data presented here allow for an estimate of the required machine time and manpower needed for the core procedures of radiotherapy in an average radiation treatment with IMRT. However, one should be aware that a number of necessary and time-consuming activities were not evaluated in the present study.

  10. Psychological distress associated with cancer screening: A systematic review.

    PubMed

    Chad-Friedman, Emma; Coleman, Sarah; Traeger, Lara N; Pirl, William F; Goldman, Roberta; Atlas, Steven J; Park, Elyse R

    2017-10-15

    Current national cancer screening recommendations include the potential risk of psychological harm related to screening. However, data on the relation of psychological distress to cancer screening is limited. The authors conducted a systematic review to assess psychological distress associated with cancer screening procedures. Studies that administered measures of psychological distress between 2 weeks before and 1 month after the screening procedure were included. In total, 22 eligible studies met criteria for review, including 13 observational trials and 9 randomized controlled trials. Eligible studies used a broad range of validated and unvalidated measures. Anxiety was the most commonly assessed construct and was measured using the State Trait Anxiety Inventory. Studies included breast, colorectal, prostate, lung, and cervical screening procedures. Distress was low across procedures, with the exception of colorectal screening. Distress did not vary according to the time at which distress was measured. None of the studies were conducted exclusively with the intention of assessing distress at the time of screening. Evidence of low distress during the time of cancer screening suggests that distress might not be a widespread barrier to screening among adults who undergo screening. However, more studies are needed using validated measures of distress to further understand the extent to which screening may elicit psychological distress and impede adherence to national screening recommendations. Cancer 2017;123:3882-94. © 2017 American Cancer Society. © 2017 American Cancer Society.

  11. Prospective randomized comparison of rotational angiography with three-dimensional reconstruction and computed tomography merged with electro-anatomical mapping: a two center atrial fibrillation ablation study.

    PubMed

    Anand, Rishi; Gorev, Maxim V; Poghosyan, Hermine; Pothier, Lindsay; Matkins, John; Kotler, Gregory; Moroz, Sarah; Armstrong, James; Nemtsov, Sergei V; Orlov, Michael V

    2016-08-01

    To compare the efficacy and accuracy of rotational angiography with three-dimensional reconstruction (3DATG) image merged with electro-anatomical mapping (EAM) vs. CT-EAM. A prospective, randomized, parallel, two-center study conducted in 36 patients (25 men, age 65 ± 10 years) undergoing AF ablation (33 % paroxysmal, 67 % persistent) guided by 3DATG (group 1) vs. CT (group 2) image fusion with EAM. 3DATG was performed on the Philips Allura Xper FD 10 system. Procedural characteristics including time, radiation exposure, outcome, and navigation accuracy were compared between two groups. There was no significant difference between the groups in total procedure duration or time spent for various procedural steps. Minor differences in procedural characteristics were present between two centers. Segmentation and fusion time for 3DATG or CT-EAM was short and similar between both centers. Accuracy of navigation guided by either method was high and did not depend on left atrial size. Maintenance of sinus rhythm between the two groups was no different up to 24 months of follow-up. This study did not find superiority of 3DATG-EAM image merge to guide AF ablation when compared to CT-EAM fusion. Both merging techniques result in similar navigation accuracy.

  12. Survey of Access to GastroEnterology in Canada: The SAGE wait times program

    PubMed Central

    Leddin, Desmond; Bridges, Ronald J; Morgan, David G; Fallone, Carlo; Render, Craig; Plourde, Victor; Gray, Jim; Switzer, Connie; McHattie, Jim; Singh, Harminder; Walli, Eric; Murray, Iain; Nestel, Anthony; Sinclair, Paul; Chen, Ying; Irvine, E Jan

    2010-01-01

    BACKGROUND: Assessment of current wait times for specialist health services in Canada is a key method that can assist government and health care providers to plan wisely for future health needs. These data are not readily available. A method to capture wait time data at the time of consultation or procedure has been developed, which should be applicable to other specialist groups and also allows for assessment of wait time trends over intervals of years. METHODS: In November 2008, gastroenterologists across Canada were asked to complete a questionnaire (online or by fax) that included personal demographics and data from one week on at least five consecutive new consultations and five consecutive procedure patients who had not previously undergone a procedure for the same indication. Wait times were collected for 18 primary indications and results were then compared with similar survey data collected in 2005. RESULTS: The longest wait times observed were for screening colonoscopy (201 days) and surveillance of previous colon cancer or polyps (272 days). The shortest wait times were for cancer-likely based on imaging or physical examination (82 days), severe or rapidly progressing dysphagia or odynophagia (83 days), documented iron-deficiency anemia (90 days) and dyspepsia with alarm symptoms (99 days). Compared with 2005 data, total wait times in 2008 were lengthened overall (127 days versus 155 days; P<0.05) and for most of the seven individual indications that permitted data comparison. CONCLUSION: Median wait times for gastroenterology services continue to exceed consensus conference recommended targets and have significantly worsened since 2005. PMID:20186352

  13. Density of total and pathogenic (tdh+) Vibrio parahaemolyticus in Atlantic and Gulf coast molluscan shellfish at harvest.

    PubMed

    Cook, David W; Bowers, John C; DePaola, Angelo

    2002-12-01

    The densities of total and pathogenic Vibrio parahaemolyticus in 671 samples of molluscan shellfish harvested in 1999 and 2000 from 14 sites in seven Gulf and Atlantic coast states were determined at 2-week intervals over a period of 12 to 16 months in each state. Changes in V. parahaemolyticus densities in shellfish between harvest and sample analysis were minimized with time and temperature controls. Densities were measured by direct plating techniques, and gene probes were used for identification. Total and pathogenic V. parahaemolyticus organisms were identified with probes for the thermolabile direct hemolysin (tlh) gene and the thermostable direct hemolysin (tdh) gene, respectively. An enrichment procedure involving 25 g of shellfish was also used for the recovery of pathogenic V. parahaemolyticus. The densities of V. parahaemolyticus in shellfish from all harvest sites were positively correlated with water temperature. Shellfish from the Gulf Coast typically had higher densities of V. parahaemolyticus than did shellfish harvested from the North Atlantic or mid-Atlantic coast. Vibrio parahaemolyticus counts exceeded 1,000 CFU/g for only 5% of all samples. Pathogenic (tdh+) V. parahaemolyticus was detected in approximately 6% of all samples by both procedures, and 61.5% of populations in the positive samples from the direct plating procedure were at the lower limit of detection (10 CFU/g). The frequency of detection of pathogenic V. parahaemolyticus was significantly related to water temperature and to the density of total V. parahaemolyticus. The failure to detect pathogenic V. parahaemolyticus in shellfish more frequently was attributed to the low numbers and uneven distribution of the organism.

  14. Value of Image Fusion in Coronary Angiography for the Detection of Coronary Artery Bypass Grafts.

    PubMed

    Plessis, Julien; Warin Fresse, Karine; Cahouch, Zachary; Manigold, Thibaut; Letocart, Vincent; Le Gloan, Laurianne; Guyomarch, Béatrice; Guerin, Patrice

    2016-06-10

    Coronary angiography is more complex in patients with coronary artery bypass grafts (CABG). Image fusion is a new technology that allows the overlay of a computed tomography (CT) three-dimension (3D) model with fluoroscopic images in real time. This single-center prospective study included 66 previous CABG patients undergoing coronary and bypass graft angiography. Image fusion coronary angiographies (fusion group, 20 patients) were compared to conventional coronary angiographies (control group, 46 patients). The fusion group included patients for whom a previous chest CT scan with contrast was available. For patients in this group, aorta and CABG were reconstructed in 3D from CT acquisitions and merged in real time with fluoroscopic images. The following parameters were compared: time needed to localize the CABG; procedure duration; air kerma (AK); dose area product (DAP); and volume of contrast media injected. Results are expressed as median. There were no significant differences between the 2 groups in patient demographics and procedure characteristics (access site, number of bypass to be found, and interventional cardiologist's experience). The time to localize CABG was significantly shorter in the fusion group (7.3 versus 12.4 minutes; P=0.002), as well as the procedure duration (20.6 versus 25.6 minutes; P=0.002), AK (610 versus 814 mGy; P=0.02), DAP (4390 versus 5922.5 cGy·cm(2); P=0.02), and volume of iodinated contrast media (85 versus 116 cc; P=0.002). 3D image fusion improves the CABG detection in coronary angiography and reduces the time necessary to localize CABG, total procedure time duration, radiation exposure, and volume of contrast media. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  15. [Handling modern imaging procedures in a high-tech operating room].

    PubMed

    Hüfner, T; Citak, M; Imrecke, J; Krettek, C; Stübig, T

    2012-03-01

    Operating rooms are the central unit in the hospital network in trauma centers. In this area, high costs but also high revenues are generated. Modern operating theater concepts as an integrated model have been offered by different companies since the early 2000s. Our hypothesis is that integrative concepts for operating rooms, in addition to improved operating room ergonomics, have the potential for measurable time and cost savings. In our clinic, an integrated operating room concept (I-Suite, Stryker, Duisburg) was implemented after analysis of the problems. In addition to the ceiling-mounted arrangement, the system includes an endoscopy unit, a navigation system, and a voice control system. In the first 6 months (9/2005 to 2/2006), 112 procedures were performed in the integrated operating room: 34 total knee arthroplasties, 12 endoscopic spine surgeries, and 66 inpatient arthroscopic procedures (28 shoulder and 38 knee reconstructions). The analysis showed a daily saving of 22-45 min, corresponding to 15-30% of the daily changeover times, calculated to account for potential savings in the internal cost allocation of 225-450 EUR. A commercial operating room concept was evaluated in a pilot phase in terms of hard data, including time and cost factors. Besides the described effects further savings might be achieved through the effective use of voice control and the benefit of the sterile handle on the navigation camera, since waiting times for an additional nurse are minimized. The time of the procedure of intraoperative imaging is also reduced due to the ceiling-mounted concept, as the C-arm can be moved freely in the operating theater without hindering cables. By these measures and ensuing improved efficiency, the initial high costs for the implementation of the system may be cushioned over time.

  16. A break-even analysis of major ear surgery.

    PubMed

    Wasson, J D; Phillips, J S

    2015-10-01

    To determine variables which affect cost and profit for major ear surgery and perform a break-even analysis. Retrospective financial analysis. UK teaching hospital. Patients who underwent major ear surgery under general anaesthesia performed by the senior author in main theatre over a 2-year period between dates of 07 September 2010 and 07 September 2012. Income, cost and profit for each major ear patient spell. Variables that affect major ear surgery profitability. Seventy-six patients met inclusion criteria. Wide variation in earnings, with a median net loss of £-1345.50 was observed. Income was relatively uniform across all patient spells; however, theatre time of major ear surgery at a cost of £953.24 per hour varied between patients and was the main determinant of cost and profit for the patient spell. Bivariate linear regression of earnings on theatre time identified 94% of variation in earnings was due to variation in theatre time (r = -0.969; P < 0.0001) and derived a break-even time for major ear surgery of 110.6 min. Theatre time was dependent on complexity of procedure and number of OPCS4 procedures performed, with a significant increase in theatre time when three or more procedures were performed during major ear surgery (P = 0.015). For major ear surgery to either break-even or return a profit, total theatre time should not exceed 110 min and 36 s. © 2015 John Wiley & Sons Ltd.

  17. Multimodal registration of three-dimensional maxillodental cone beam CT and photogrammetry data over time.

    PubMed

    Bolandzadeh, N; Bischof, W; Flores-Mir, C; Boulanger, P

    2013-01-01

    In recent years, one of the foci of orthodontics has been on systems for the evaluation of treatment results and the tracking of tissue variations over time. This can be accomplished through analysing three-dimensional orthodontic images obtained before and after the treatments. Since complementary information is achieved by integrating multiple imaging modalities, cone beam CT (CBCT) and stereophotogrammetry technologies are used in this study to develop a method for tracking bone, teeth and facial soft-tissue variations over time. We propose a two-phase procedure of multimodal (Phase 1) and multitemporal (Phase 2) registration which aligns images taken from the same patient by different imaging modalities and at different times. Extrinsic (for Phase 1) and intrinsic (for Phase 2) landmark-based registration methods are employed as an initiation for a robust iterative closest points algorithm. Since the mandible moves independently of the upper skull, the registration procedure is applied separately on the mandible and the upper skull. The results show that the signed error distributions of both mandible and skull registrations follow a mixture of two Gaussian distributions, corresponding to alignment errors (due to our method) and temporal change over time. We suggest that the large values among the total registration errors correspond to the temporal change resulting from (1) the effect of treatment (i.e. the orthodontic changes of teeth positions); (2) the biological changes such as teeth growth over time, especially for teenagers; and (3) the segmentation procedure and CBCT precision change over time.

  18. Visually guided male urinary catheterization: a feasibility study.

    PubMed

    Willette, Paul A; Banks, Kevin; Shaffer, Lynn

    2013-01-01

    Ten percent to 15% of urinary catheterizations involve complications. New techniques to reduce risks and pain are indicated. This study examines the feasibility and safety of male urinary catheterization by nursing personnel using a visually guided device in a clinical setting. The device, a 0.6-mm fiber-optic bundle inside a 14F triple-lumen flexible urinary catheter with a lubricious coating, irrigation port, and angled tip, connects to a camera, allowing real-time viewing of progress on a color monitor. Two emergency nurses were trained to use the device. Male patients 18 years or older presenting to the emergency department with an indication for urinary catheterization using a standard Foley or Coudé catheter were eligible to participate in the study. Exclusion criteria were a current suprapubic tube or gross hematuria prior to the procedure. Twenty-five patients were enrolled. Data collected included success of placement, total procedure time, pre-procedure pain and maximum pain during the procedure, gross hematuria, abnormalities or injuries identified if catheterization failed, occurrence of and reason for equipment failures, and number of passes required for placement. All catheters were successfully placed. The median number of passes required was 1. For all but one patient, procedure time was ≤ 17 minutes. A median increase in pain scores of 1 point from baseline to the maximum was reported. Gross hematuria was observed in 2 patients. The success rate for placement of a Foley catheter with the visually guided device was 100%, indicating its safety, accuracy, and feasibility in a clinical setting. Minimal pain was associated with the procedure. Copyright © 2013 Emergency Nurses Association. Published by Mosby, Inc. All rights reserved.

  19. Blood management and transfusion strategies in 600 patients undergoing total joint arthroplasty: an analysis of pre-operative autologous blood donation.

    PubMed

    Perazzo, Paolo; Viganò, Marco; De Girolamo, Laura; Verde, Francesco; Vinci, Anna; Banfi, Giuseppe; Romagnoli, Sergio

    2013-07-01

    Blood loss during total joint arthroplasty strongly influences the time to recover after surgery and the quality of the recovery. Blood conservation strategies such as pre-operative autologous blood donation and post-operative cell salvage are intended to avoid allogeneic blood transfusions and their associated risks. Although widely investigated, the real effectiveness of these alternative transfusion practices remains controversial. The surgery reports of 600 patients undergoing total joint arthroplasty (312 hip and 288 knee replacements) were retrospectively reviewed to assess transfusion needs and related blood management at our institute. Evaluation parameters included post-operative blood loss, haemoglobin concentration measured at different time points, ASA score, and blood transfusion strategies. Autologous blood donation increased the odds of receiving a red blood cell transfusion. Reinfusion by a cell salvage system of post-operative shed blood was found to limit adverse effects in cases of severe post-operative blood loss. The peri-operative net decrease in haemoglobin concentration was higher in patients who had predeposited autologous blood than in those who had not. The strengths of this study are the high number of cases and the standardised procedures, all operations having been performed by a single orthopaedic surgeon and a single anaesthesiologist. Our data suggest that a pre-operative autologous donation programme may often be useless, if not harmful. Conversely, the use of a cell salvage system may be effective in reducing the impact of blood transfusion on a patient's physiological status. Basal haemoglobin concentration emerged as a useful indicator of transfusion probability in total joint replacement procedures.

  20. Rainfall, Streamflow, and Water-Quality Data During Stormwater Monitoring, Halawa Stream Drainage Basin, Oahu, Hawaii, July 1, 2005 to June 30, 2006

    USGS Publications Warehouse

    Presley, Todd K.; Jamison, Marcael T.J.; Young-Smith, Stacie T. M.

    2006-01-01

    Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. This program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream. For this program, rainfall data were collected at two stations, continuous discharge data at one station, continuous streamflow data at two stations, and water-quality data at five stations, which include the continuous discharge and streamflow stations. This report summarizes rainfall, discharge, streamflow, and water-quality data collected between July 1, 2005 and June 30, 2006. A total of 23 samples was collected over five storms during July 1, 2005 to June 30, 2006. The goal was to collect grab samples nearly simultaneously at all five stations, and flow-weighted time-composite samples at the three stations equipped with automatic samplers; however, all five storms were partially sampled owing to lack of flow at the time of sampling at some sites, or because some samples collected by the automatic sampler did not represent water from the storm. Samples were analyzed for total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, chromium, copper, lead, nickel, and zinc). Additionally, grab samples were analyzed for oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Quality-assurance/quality-control samples were also collected during storms and during routine maintenance to verify analytical procedures and check the effectiveness of equipment-cleaning procedures.

  1. Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study.

    PubMed

    Yusof, Mohd Yusmiaidil Putera Mohd; Rahman, Nur Liyana Abdul; Asri, Amiza Aqiela Ahmad; Othman, Noor Ilyani; Wan Mokhtar, Ilham

    2017-12-01

    This study was performed to quantify the repeat rate of imaging acquisitions based on different clinical examinations, and to assess the prevalence of error types in intraoral bitewing and periapical imaging using a digital complementary metal-oxide-semiconductor (CMOS) intraoral sensor. A total of 8,030 intraoral images were retrospectively collected from 3 groups of undergraduate clinical dental students. The type of examination, stage of the procedure, and reasons for repetition were analysed and recorded. The repeat rate was calculated as the total number of repeated images divided by the total number of examinations. The weighted Cohen's kappa for inter- and intra-observer agreement was used after calibration and prior to image analysis. The overall repeat rate on intraoral periapical images was 34.4%. A total of 1,978 repeated periapical images were from endodontic assessment, which included working length estimation (WLE), trial gutta-percha (tGP), obturation, and removal of gutta-percha (rGP). In the endodontic imaging, the highest repeat rate was from WLE (51.9%) followed by tGP (48.5%), obturation (42.2%), and rGP (35.6%). In bitewing images, the repeat rate was 15.1% and poor angulation was identified as the most common cause of error. A substantial level of intra- and interobserver agreement was achieved. The repeat rates in this study were relatively high, especially for certain clinical procedures, warranting training in optimization techniques and radiation protection. Repeat analysis should be performed from time to time to enhance quality assurance and hence deliver high-quality health services to patients.

  2. Diabetes Mellitus and Hyperglycemia and the Risk of Aseptic Loosening in Total Joint Arthroplasty.

    PubMed

    Maradit Kremers, Hilal; Schleck, Cathy D; Lewallen, Eric A; Larson, Dirk R; Van Wijnen, Andre J; Lewallen, David G

    2017-09-01

    It is unknown to what extent diabetes mellitus modifies the long-term risk of aseptic loosening in total hip arthroplasty (THA) and total knee arthroplasty (TKA). We examined the association between diabetes mellitus, perioperative hyperglycemia, and the likelihood of revisions for aseptic loosening. We studied 16,085 primary THA and TKA procedures performed at a large tertiary care hospital between 2002 and 2009. All blood glucose values around the time of surgery (within 1 week) were retrieved. Subsequent revision surgeries and the reasons for revision were ascertained through the institutional joint registry. Multivariate Cox models were used to estimate the hazard ratios (HRs) and 95% confidence intervals (CIs) for aseptic loosening associated with diabetes mellitus and hyperglycemia adjusting for age, gender, body mass index, and surgery type. A total of 2911 (18%) surgeries had a diagnosis of diabetes mellitus at the time of surgery. Glucose testing was performed at least once in 7055 (44%) procedures within ±1 week of surgery. Although diabetic patients did not experience a higher risk of revision for aseptic loosening (HR, 0.87; 95% CI, 0.55-1.38), higher preoperative glucose values on the day before surgery were significantly associated with both the overall risk of revisions (HR, 2.80; 95% CI, 1.00-7.85) and revisions for aseptic loosening (HR, 4.95; 95% CI, 1.26-19.54). High preoperative hyperglycemia is a potential risk factor for aseptic loosening in THA and TKA. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Total laparoscopic reversal of Hartmann's procedure.

    PubMed

    Masoni, Luigi; Mari, Francesco Saverio; Nigri, Giuseppe; Favi, Francesco; Pindozzi, Fioralba; Dall'Oglio, Anna; Pancaldi, Alessandra; Brescia, Antonio

    2013-01-01

    Hartmann's procedure is still performed in those cases in which colorectal anastomosis might be unsafe. Reversal of Hartmann's procedure (HR) is considered a major surgical procedure with a high morbidity (55 to 60%) and mortality rate (0 to 4%). To decrease these rates, laparoscopic Hartmann's reversal procedure was successfully experienced. We report our totally laparoscopic Hartmann's reversal technique. Between 2004 and 2010 we performed 27 HRs with a totally laparoscopic approach. The efficacy and safety of this technique were demonstrated evaluating the operative data, postoperative complications, and the outcome of the patients. There were no open conversions or major intraoperative complications. Anastomotic leaking occurred in one patient requiring an ileostomy; one patient needed a blood transfusion and one had a nosocomial pneumonia. The mean postoperative hospitalization was 5.7 days. Laparoscopic HR is a feasible and safe procedure and can be considered a valid alternative to open HR.

  4. Acute procedural outcomes of orbital atherectomy for the treatment of common femoral artery disease: Sub-analysis of the CONFIRM Registries.

    PubMed

    Lee, Michael S; Heikali, Daniel; Mustapha, Jihad; Adams, George; Mahmud, Ehtisham

    2017-08-01

    This analysis compared the angiographic outcomes of patients treated with orbital atherectomy for calcified common femoral artery (CFA) and superficial femoral artery (SFA) disease. The ideal revascularization strategy for CFA disease is unknown. Endarterectomy has been considered the standard of care for CFA disease for over 50 years. Endovascular intervention is becoming more commonly used to revascularize the CFA given the advances in technology and the less invasive nature of the procedure. Patient demographics, lesion characteristics, and procedure data for all CONFIRM patients with at least one CFA lesion location ( n=147 patients; n=200 lesions) were compared to patients with at least one SFA lesion location ( n=1508 patients; n=2367 lesions). The primary endpoint was angiographic complication, defined as the composite of dissection, perforation, slow flow, closure, spasm, embolism, or thrombosis. The CFA group had more patients with Rutherford class 4 and shorter lesion length. The CFA group had a higher final residual stenosis, shorter total run time, and shorter total inflation time. The primary endpoint was lower in the CFA group compared with the SFA group (17% vs 24%, p=0.02), driven by a lower dissection rate (10% vs 15%, p=0.04). Plaque modification of the CFA with orbital atherectomy was safe and compared favorably with SFA disease. The need for bail-out stenting was low. A randomized trial is needed to determine the ideal treatment strategy for calcified CFA disease.

  5. Infiltration with lidocaine and adrenaline instead of normal saline does not improve the septoplasty procedure.

    PubMed

    Gungor, Volkan; Baklaci, Deniz; Kum, Rauf Oguzhan; Yilmaz, Yavuz Fuat; Ozcan, Muge; Unal, Adnan

    2016-08-01

    The aim of this study was to determine whether infiltration of local anesthetics with adrenaline improved septoplasty procedure when compared to normal saline. Eight-two patients undergoing septoplasty were randomized into two groups. In group 1, septal mucoperichondrium was infiltrated with lidocaine with adrenaline, and normal saline was used in group 2. Presence of intra-operative septal mucosal injuries, the amount of bleeding, arterial blood pressure, operation time as well as the quality of the surgical field and the convenience of finding the correct surgical plane as determined by the surgeon using a 5-point scale were compared between two groups. There were no significant differences for the amount of blood loss, mean arterial pressure, operation time, or scores for convenience of finding the correct surgical plane between the two groups. There was no significant difference for intra-operative simple (P = 0.631) and total (simple+severe) (P = 0.649) septal mucoperichondrial injuries between groups 1 and 2, either. However, severe mucoperichondrial injury rate was higher in the patients infiltrated with lidocaine and adrenaline (P = 0.026), and the quality of the surgical field was worse in the patients injected with normal saline (P = 0.0179). Infiltration of septal mucoperichondrium with lidocaine and adrenaline instead of normal saline was not advantageous in terms of objective parameters tested, including bleeding amount and duration of surgery as well as the of the total mucosal injury rate in septoplasty procedure.

  6. Benchmarking emergency department thoracotomy: Using trauma video review to generate procedural norms.

    PubMed

    Dumas, Ryan P; Chreiman, Kristen M; Seamon, Mark J; Cannon, Jeremy W; Reilly, Patrick M; Christie, Jason D; Holena, Daniel N

    2018-05-23

    Emergency department thoracotomy (EDT) must be rapid and well-executed. Currently there are no defined benchmarks for EDT procedural milestones. We hypothesized that trauma video review (TVR) can be used to define the 'normative EDT' and generate procedural benchmarks. As a secondary aim, we hypothesized that data collected by TVR would have less missingness and bias than data collected by review of the Electronic Medical Record (EMR). We used continuously recording video to review all EDTs performed at our centre during the study period. Using skin incision as start time, we defined four procedural milestones for EDT: 1. Decompression of the right chest (tube thoracostomy, finger thoracostomy, or clamshell thoracotomy with transverse sternotomy performed in conjunction with left anterolateral thoracotomy) 2. Retractor deployment 3. Pericardiotomy 4. Aortic Cross-clamp. EDTs with any milestone time ≥ 75 th percentile of time or during which a milestone was omitted were identified as outliers. We compared rates of missingness in data collected by TVR and EMR using McNemar's test. 44 EDTs were included from the study period. Patients had a median age of 30 [IQR 25-44] and were predominantly African-American (95%) males (93%) with penetrating trauma (95%). From skin incision, median times in minutes to milestones were as follows: right chest decompression: 2.11 [IQR 0.68-2.83], retractor deployment 1.35 [IQR 0.96-1.85], pericardiotomy 2.35 [IQR 1.85-3.75], aortic cross-clamp 3.71 [IQR 2.83-5.77]. In total, 28/44 (64%) of EDTs were either high outliers for one or more benchmarks or had milestones that were omitted. For all milestones, rates of missingness for TVR data were lower than EMR data (p < 0.001). Video review can be used to define normative times for the procedural milestones of EDT. Steps exceeding the 75 th percentile of time were common, with over half of EDTs having at least one milestone as an outlier. Data quality is higher using TVR compared to EMR collection. Future work should seek to determine if minimizing procedural technical outliers improves patient outcomes. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. 78 FR 69493 - Self-Regulatory Organizations; NYSE Arca, Inc.; Notice of Filing and Immediate Effectiveness of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-19

    ... additions are made. The total number of Quarterly Options Series that can be listed at any one time is.... To help ensure that only active options series are listed, Exchange procedures are designed to delist... Change Amending Commentary .08 to Rule 6.4 To Modify the Quarterly Option Series Program To Eliminate the...

  8. Estimating Cone and Seed Production and Monitoring Pest Damage in Southern Pine Seed Orchards

    Treesearch

    Carl W. Fatzinger; H. David Muse; Thomas Miller; Helen T. Bhattacharyya

    1988-01-01

    Field sampling procedures and computer programs are described for monitoring seed production and pest damage in southern pine seed orchards. The system estimates total orchard yields of female strobili and seeds, quantifies pest damage, determines times of year when losses occur, and produces life tables for female strobili. An example is included to illustrate the...

  9. Placement of central venous port catheters and peripherally inserted central catheters in the routine clinical setting of a radiology department: analysis of costs and intervention duration learning curve.

    PubMed

    Rotzinger, Roman; Gebauer, Bernhard; Schnapauff, Dirk; Streitparth, Florian; Wieners, Gero; Grieser, Christian; Freyhardt, Patrick; Hamm, Bernd; Maurer, Martin H

    2017-12-01

    Background Placement of central venous port catheters (CVPS) and peripherally inserted central catheters (PICC) is an integral component of state-of-the-art patient care. In the era of increasing cost awareness, it is desirable to have more information to comprehensively assess both procedures. Purpose To perform a retrospective analysis of interventional radiologic implantation of CVPS and PICC lines in a large patient population including a cost analysis of both methods as well as an investigation the learning curve in terms of the interventions' durations. Material and Methods All CVPS and PICC line related interventions performed in an interventional radiology department during a three-year period from January 2011 to December 2013 were examined. Documented patient data included sex, venous access site, and indication for CVPS or PICC placement. A cost analysis including intervention times was performed based on the prorated costs of equipment use, staff costs, and expenditures for disposables. The decrease in intervention duration in the course of time conformed to the learning curve. Results In total, 2987 interventions were performed by 16 radiologists: 1777 CVPS and 791 PICC lines. An average implantation took 22.5 ± 0.6 min (CVPS) and 10.1 ± 0.9 min (PICC lines). For CVPS, this average time was achieved by seven radiologists newly learning the procedures after performing 20 CVPS implantations. Total costs per implantation were €242 (CVPS) and €201 (PICC lines). Conclusion Interventional radiologic implantations of CVPS and PICC lines are well-established procedures, easy to learn by residents, and can be implanted at low costs.

  10. Single site and conventional totally extraperitoneal techniques for uncomplicated inguinal hernia repair: A comparative study.

    PubMed

    de Araújo, Felipe Brandão Corrêa; Starling, Eduardo Simão; Maricevich, Marco; Tobias-Machado, Marcos

    2014-10-01

    To demonstrate the feasibility of endoscopic extraperitoneal single site (EESS) inguinal hernia repair and compare it outcomes with the conventional totally extraperitoneal (TEP) technique. TEP inguinal hernia repair is a widely accepted alternative to conventional open technique with several perioperative advantages. Transumbilical laparoendoscopic singlesite surgery (LESS) is an emerging approach and has been reported for a number of surgical procedures with superior aesthetic results but other advantages need to be proven. Thirty-eight uncomplicated inguinal hernias were repaired by EESS approach between January 2010 and January 2011. All procedures were performed through a 25 cm infraumbilical incision using the Alexis wound retractor attached to a surgical glove and three trocars. Body mass index, age, operative time, blood loss, complications, conversion rate, analgesia requirement, hospital stay, return to normal activities and patient satisfaction with aesthetic results were analysed and compared with the last 38 matched-pair group of patients who underwent a conventional TEP inguinal hernia repair by the same surgeon. All procedures were performed successfully with no conversion. In both unilateral and bilateral EESS inguinal repairs, the mean operative time was longer than conventional TEP (55± 20 vs. 40± 15 min, P = 0.049 and 70± 15 vs. 55± 10 min, P = 0.014). Aesthetic result was superior in the EESS group (2.88± 0.43 vs. 2.79± 0.51, P = 0.042). There was no difference between the two approaches regarding blood loss, complications, hospital stay, time until returns to normal activities and analgesic requirement. EESS inguinal hernia repair is safe and effective, with superior cosmetic results in the treatment of uncomplicated inguinal hernias. Other advantages of this new technique still need to be proven.

  11. 1.0 s Ultrafast MRI in non-sedated infants after reduction with spica casting for developmental dysplasia of the hip: a feasibility study.

    PubMed

    Fukuda, Atsushi; Fukiage, Kenichi; Futami, Tohru; Miyati, Tosiaki

    2016-06-01

    The aim of this study was to first develop and use 1.0 s ultrafast magnetic resonance imaging (MRI) to confirm the location of the femoral head in non-sedated infants with developmental dysplasia of the hip (DDH) after reduction with spica cast application in clinical settings. The ultrafast acquisition was achieved by employing a balanced steady-state free precession sequence and immobilizing the patient with dedicated sandbags. On completion of the ultrafast MRI study, all infants were sedated for conventional MRI scanning. Two orthopaedic surgeons retrospectively evaluated the image quality, result of the reduction and total MRI study time (including patient immobilization, coil setup, and scanning) in 14 DDHs of 13 infants (one with bilateral DDHs). Both reviewers stated that there were no motion artefacts for non-sedated infants during the ultrafast MRI and that the quality of both the ultrafast and conventional MRI images were acceptable to assess the femoral head location. Assessment of the reduction procedure resulted in two hips being categorized as 'incomplete reduction' requiring a re-reduction procedure. The total study time of ultrafast and conventional MRI was 6 ± 1 min and 14 ± 3 min, respectively (P < 0.001). No complications due to sedation, such as hypoxia, were reported. The average sedation waiting time was 1 h 25 min ± 34 min. The ultrafast MRI procedure reported here can be readily employed to confirm the location of the femoral head in infants with DDHs, without the use of any sedation.

  12. Virtual reality, ultrasound-guided liver biopsy simulator: development and performance discrimination

    PubMed Central

    Johnson, S J; Hunt, C M; Woolnough, H M; Crawshaw, M; Kilkenny, C; Gould, D A; England, A; Sinha, A; Villard, P F

    2012-01-01

    Objectives The aim of this article was to identify and prospectively investigate simulated ultrasound-guided targeted liver biopsy performance metrics as differentiators between levels of expertise in interventional radiology. Methods Task analysis produced detailed procedural step documentation allowing identification of critical procedure steps and performance metrics for use in a virtual reality ultrasound-guided targeted liver biopsy procedure. Consultant (n=14; male=11, female=3) and trainee (n=26; male=19, female=7) scores on the performance metrics were compared. Ethical approval was granted by the Liverpool Research Ethics Committee (UK). Independent t-tests and analysis of variance (ANOVA) investigated differences between groups. Results Independent t-tests revealed significant differences between trainees and consultants on three performance metrics: targeting, p=0.018, t=−2.487 (−2.040 to −0.207); probe usage time, p = 0.040, t=2.132 (11.064 to 427.983); mean needle length in beam, p=0.029, t=−2.272 (−0.028 to −0.002). ANOVA reported significant differences across years of experience (0–1, 1–2, 3+ years) on seven performance metrics: no-go area touched, p=0.012; targeting, p=0.025; length of session, p=0.024; probe usage time, p=0.025; total needle distance moved, p=0.038; number of skin contacts, p<0.001; total time in no-go area, p=0.008. More experienced participants consistently received better performance scores on all 19 performance metrics. Conclusion It is possible to measure and monitor performance using simulation, with performance metrics providing feedback on skill level and differentiating levels of expertise. However, a transfer of training study is required. PMID:21304005

  13. Handheld Navigation Device and Patient-Specific Cutting Guides Result in Similar Coronal Alignment for Primary Total Knee Arthroplasty: a Retrospective Matched Cohort Study.

    PubMed

    Steinhaus, Michael E; McLawhorn, Alexander S; Richardson, Shawn S; Maher, Patrick; Mayman, David J

    2016-10-01

    Proper alignment of total knee arthroplasty (TKA) is essential for TKA function and may reduce the risk of aseptic failure. Technologies that prevent malalignment may reduce the risk of revision surgery. The purpose of this study was to compare two competing TKA systems that purport improved alignment: patient-specific instrumentation (PSI), and a handheld portable navigation device (NAV). After IRB approval, 49 consecutive PSI TKAs (40 patients) were matched based on preoperative characteristics to 49 NAV TKAs (40 patients) performed by a single surgeon. A blinded observer measured alignment on digital radiographs. Operating room records were reviewed for procedure times. Two-tailed paired sample t tests and McNemar's test were used as appropriate. Alpha level was 0.05 for all tests. Preoperative cohort characteristics were not different. Mean postoperative long-leg mechanical alignment was within ±1° of neutral for both groups, although statistically different ( p  = 0.026). There were no other significant differences in coronal alignment. PSI exhibited significantly greater posterior tibial slope (4.4°) compared to NAV (2.7°) ( p  = 0.004); PSI resulted in significantly more outliers (>6°; p  = 0.004). Procedure time for unilateral TKAs was lower for PSI (74.4 min) compared to that for NAV (80.6 min; p  = 0.023). NAV and PSI technologies provided excellent coronal plane alignment. NAV was better for sagittal tibial slope, while PSI procedure times were shorter for unilateral TKA. The impact of these technologies on patient-reported outcomes and TKA survivorship is controversial and should be the focus of future research.

  14. Towards cybernetic surgery: robotic and augmented reality-assisted liver segmentectomy.

    PubMed

    Pessaux, Patrick; Diana, Michele; Soler, Luc; Piardi, Tullio; Mutter, Didier; Marescaux, Jacques

    2015-04-01

    Augmented reality (AR) in surgery consists in the fusion of synthetic computer-generated images (3D virtual model) obtained from medical imaging preoperative workup and real-time patient images in order to visualize unapparent anatomical details. The 3D model could be used for a preoperative planning of the procedure. The potential of AR navigation as a tool to improve safety of the surgical dissection is outlined for robotic hepatectomy. Three patients underwent a fully robotic and AR-assisted hepatic segmentectomy. The 3D virtual anatomical model was obtained using a thoracoabdominal CT scan with a customary software (VR-RENDER®, IRCAD). The model was then processed using a VR-RENDER® plug-in application, the Virtual Surgical Planning (VSP®, IRCAD), to delineate surgical resection planes including the elective ligature of vascular structures. Deformations associated with pneumoperitoneum were also simulated. The virtual model was superimposed to the operative field. A computer scientist manually registered virtual and real images using a video mixer (MX 70; Panasonic, Secaucus, NJ) in real time. Two totally robotic AR segmentectomy V and one segmentectomy VI were performed. AR allowed for the precise and safe recognition of all major vascular structures during the procedure. Total time required to obtain AR was 8 min (range 6-10 min). Each registration (alignment of the vascular anatomy) required a few seconds. Hepatic pedicle clamping was never performed. At the end of the procedure, the remnant liver was correctly vascularized. Resection margins were negative in all cases. The postoperative period was uneventful without perioperative transfusion. AR is a valuable navigation tool which may enhance the ability to achieve safe surgical resection during robotic hepatectomy.

  15. The AES total ankle replacement: A mid-term analysis of 93 cases.

    PubMed

    Henricson, Anders; Knutson, Kaj; Lindahl, Johan; Rydholm, Urban

    2010-06-01

    There are few studies concerning specific total ankle arthroplasties. This study reports mid-term survival data for the AES prosthesis. Ninety-three AES ankle arthroplasties were performed by the senior authors. The mean follow-up was 3.5 years. The 5-year survivorship and also the number of simultaneous procedures, reoperations, additional procedures and revisions are analyzed. The 5-year survivorship with revision for any reason as end-point was 90%. Simultaneous procedures were performed in 25 patients, deltoid release and subtalar fusion being the most common. There were seven revisions, one due to loosening, and two due to infection, instability and fractures, respectively. Twenty-seven reoperations or additional procedures were performed in 23 patients with a procedure for malleolar impingement being the most common reoperation, and correction of hindfoot varus being the most common reason for an additional procedure. The AES total ankle replacement seems to be a reasonably safe procedure in experienced hands. Copyright 2009 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  16. Discharges with surgical procedures performed less often than once per month per hospital account for two-thirds of hospital costs of inpatient surgery.

    PubMed

    O'Neill, Liam; Dexter, Franklin; Park, Sae-Hwan; Epstein, Richard H

    2017-09-01

    Most surgical discharges (54%) at the average hospital are for procedures performed no more often than once per month at that hospital. We hypothesized that such uncommon procedures would be associated with an even greater percentage of the total cost of performing all surgical procedures at that hospital. Observational study. State of Texas hospital discharge abstract data: 4th quarter of 2015 and 1st quarter of 2016. Inpatients discharged with a major therapeutic ("operative") procedure. For each of N=343 hospitals, counts of discharges, sums of lengths of stay (LOS), sums of diagnosis related group (DRG) case-mix weights, and sums of charges were obtained for each procedure or combination of procedures, classified by International Classification of Diseases version 10 Procedure Coding System (ICD-10-PCS). Each discharge was classified into 2 categories, uncommon versus not, defined as a procedure performed at most once per month versus those performed more often than once per month. Major procedures performed at most once per month per hospital accounted for an average among hospitals of 68% of the total inpatient costs associated with all major therapeutic procedures. On average, the percentage of total costs associated with uncommon procedures was 26% greater than expected based on their share of total discharges (P<0.00001). Average percentage differences were insensitive to the endpoint, with similar results for the percentage of patient days and percentage of DRG case-mix weights. Approximately 2/3rd (mean 68%) of inpatient costs among surgical patients can be attributed to procedures performed at most once per month per hospital. The finding that such uncommon procedures account for a large percentage of costs is important because methods of cost accounting by procedure are generally unsuitable for them. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Predicting the difficulty of a lead extraction procedure: the LED index.

    PubMed

    Bontempi, Luca; Vassanelli, Francesca; Cerini, Manuel; D'Aloia, Antonio; Vizzardi, Enrico; Gargaro, Alessio; Chiusso, Francesco; Mamedouv, Rashad; Lipari, Alessandro; Curnis, Antonio

    2014-08-01

    According to recent surveys, many sites performing permanent lead extractions do not meet the minimum prerequisites concerning personnel training, procedures' volume, or facility requirements. The current Heart Rhythm Society consensus on lead extractions suggests that patients should be referred to more experienced sites when a better outcome could be achieved. The purpose of this study was to develop a score aimed at predicting the difficulty of a lead extraction procedure through the analysis of a high-volume center database. This score could help to discriminate patients who should be sent to a referral site. A total of 889 permanent leads were extracted from 469 patients. All procedures were performed from January 2009 to May 2012 by two expert electrophysiologists, at the University Hospital of Brescia. Factors influencing the difficulty of a procedure were assessed using a univariate and a multivariate logistic regression model. The fluoroscopy time of the procedure was taken as an index of difficulty. A Lead Extraction Difficulty (LED) score was defined, considering the strongest predictors. Overall, 873 of 889 (98.2%) leads were completely removed. Major complications were reported in one patient (0.2%) who manifested cardiac tamponade. Minor complications occurred in six (1.3%) patients. No deaths occurred. Median fluoroscopic time was 8.7 min (3.3-17.3). A procedure was classified as difficult when fluoroscopy time was more than 31.2 min [90th percentile (PCTL)].At a univariate analysis, the number of extracted leads and years from implant were significantly associated with an increased risk of fluoroscopy time above 90th PCTL [odds ratio (OR) 1.51, 95% confidence interval (CI) 1.08-2.11, P = 0.01; and OR 1.19, 95% CI 1.12-1.25, P < 0.001, respectively). After adjusting for patient age and sex, and combining with other covariates potentially influencing the extraction procedure, a multivariate analysis confirmed a 71% increased risk of fluoroscopy time above 90th PCTL for each additional lead extracted (OR 1.71, 95% CI 1.06-2.77, P = 0.028) and a 23% increased risk for each year of lead age (OR 1.23, 95% CI 1.15-1.31, P < 0.001). Further nonindependent factors increasing the risk were the presence of active fixation leads and dual-coil implantable cardiac defibrillator leads. Conversely, vegetations significantly favored lead extraction.The LED score was defined as: number of extracted leads within a procedure + lead age (years from implant) + 1 if dual-coil - 1 if vegetation. The LED score independently predicted complex procedure (with fluoroscopic time >90th PCTL) both at univariate and multivariate analysis. A receiver-operating characteristic analysis showed an area under the curve of 0.81. A LED score greater than 10 could predict fluoroscopy time above 90th PCTL with a sensitivity of 78.3% and a specificity of 76.7%. The LED score is easy to compute and potentially predicts fluoroscopy time above 90th PCTL with a relatively high accuracy.

  18. Inguinal hernia repair: totally preperitoneal laparoscopic approach versus Stoppa operation: randomized trial of 100 cases.

    PubMed

    Champault, G G; Rizk, N; Catheline, J M; Turner, R; Boutelier, P

    1997-12-01

    In a prospective randomized trial comparing the totally preperitoneal (TPP) laparoscopic approach and the Stoppa procedure (open), 100 patients with inguinal hernias (Nyhus IIIA, IIIB, IV) were followed over a 3-year period. Both groups were epidemiologically comparable. In the laparoscopic group, operating time was significantly longer (p = 0.01), but hospital stay (3.2 vs. 7.3 days) and delay in return to work (17 vs. 35 days) were significantly reduced (p = 0.01). Postoperative comfort (less pain) was better (p = 0.001) after laparoscopy. In this group, morbidity was also reduced (4 vs. 20%; p = 0.02). The mean follow-up was 605 days, and 93% of the patients were reviewed at 3 years. There were three (6%) recurrences after TPP, especially at the beginning of the surgeon's learning curve, versus one for the Stoppa procedure (NS). For bilateral hernias, the authors suggest the use of a large prosthesis rather than two small ones to minimize the likelihood of recurrence. In the conditions described, the laparoscopic (TPP) approach to inguinal hernia treatment appears to have the same long-term recurrence rate as the open (Stoppa) procedure but a real advantage in the early postoperative period.

  19. Low organisational justice and heavy drinking: a prospective cohort study.

    PubMed

    Kouvonen, Anne; Kivimäki, Mika; Elovainio, Marko; Väänänen, Ari; De Vogli, Roberto; Heponiemi, Tarja; Linna, Anne; Pentti, Jaana; Vahtera, Jussi

    2008-01-01

    To investigate whether low perceived organisational injustice predicts heavy drinking among employees. Data from a prospective occupational cohort study, the 10-Town Study, on 15 290 Finnish public sector local government employees nested in 2432 work units, were used. Non-drinkers were excluded. Procedural, interactional and total organisational justice, heavy drinking (>/=210 g of absolute alcohol per week) and other psychosocial factors were determined by means of questionnaire in 2000-2001 (phase 1) and 2004 (phase 2). Multilevel logistic regression analyses taking into account the hierarchical structure of the data were conducted and adjustments were made for sex, age, socio-economic status, marital status, baseline heavy drinking, psychological distress and other psychosocial risk factors such as job strain and effort/reward imbalance. After adjustments, participants who reported low procedural justice at phase 1 were approximately 1.2 times more likely to be heavy drinkers at phase 2 compared with their counterparts reporting high justice. Low perceived justice in interpersonal treatment and low perceived total organisational justice were associated with increased prevalence of heavy drinking only in the model adjusted for sociodemographics. This is the first longitudinal study to show that low procedural justice is weakly associated with an increased likelihood of heavy drinking.

  20. Direct costs of emergency medical care: a diagnosis-based case-mix classification system.

    PubMed

    Baraff, L J; Cameron, J M; Sekhon, R

    1991-01-01

    To develop a diagnosis-based case mix classification system for emergency department patient visits based on direct costs of care designed for an outpatient setting. Prospective provider time study with collection of financial data from each hospital's accounts receivable system and medical information, including discharge diagnosis, from hospital medical records. Three community hospital EDs in Los Angeles County during selected times in 1984. Only direct costs of care were included: health care provider time, ED management and clerical personnel excluding registration, nonlabor ED expense including supplies, and ancillary hospital services. Indirect costs for hospitals and physicians, including depreciation and amortization, debt service, utilities, malpractice insurance, administration, billing, registration, and medical records were not included. Costs were derived by valuing provider time based on a formula using annual income or salary and fringe benefits, productivity and direct care factors, and using hospital direct cost to charge ratios. Physician costs were based on a national study of emergency physician income and excluded practice costs. Patients were classified into one of 216 emergency department groups (EDGs) on the basis of the discharge diagnosis, patient disposition, age, and the presence of a limited number of physician procedures. Total mean direct costs ranged from $23 for follow-up visit to $936 for trauma, admitted, with critical care procedure. The mean total direct costs for the 16,771 nonadmitted patients was $69. Of this, 34% was for ED costs, 45% was for ancillary service costs, and 21% was for physician costs. The mean total direct costs for the 1,955 admitted patients was $259. Of this, 23% was for ED costs, 63% was for ancillary service costs, and 14% was for physician costs. Laboratory and radiographic services accounted for approximately 85% of all ancillary service costs and 38% of total direct costs for nonadmitted patients versus 80% of ancillary service costs and 51% of total direct costs for admitted patients. We have developed a diagnosis-based case mix classification system for ED patient visits based on direct costs of care designed for an outpatient setting which, unlike diagnosis-related groups, includes the measurement of time-based cost for physician and nonphysician services. This classification system helps to define direct costs of hospital and physician emergency services by type of patient.

  1. Administration of anesthetic and analgesic prevent the suppression of many leukocyte responses following surgical castration and physical dehorning.

    PubMed

    Ballou, M A; Sutherland, M A; Brooks, T A; Hulbert, L E; Davis, B L; Cobb, C J

    2013-02-15

    The objectives of the current research were to determine the physiological effects and responses of many leukocytes following surgical castration and/(or) physical dehorning and the influence of anesthetics and analgesics in 3-month-old calves. Eighty 3-month-old Holstein bull calves were completely randomized to treatments in a 2 × 2 × 2 factorial arrangement with castration, dehorning, and anesthetic/analgesic as the main effects. Peripheral blood samples were collected just before (0) and 0.5, 1.5, 2.5, 4, 6, 24, and 72 h after the respective procedure(s) and analyzed for total leukocyte and differential counts, as well as plasma cortisol and haptoglobin concentrations. Blood from the 0, 0.5 and 24h collections were analyzed for many ex vivo leukocyte responses. Data were analyzed using a repeated measures analysis of variance with the fixed effects of treatment, time, and the interaction of treatment × time. Pre-planned contrasts were performed to determine the effect of (1) management procedure (castration and/(or) dehorning), (2) anesthetic/analgesic, and (3) were the management procedures additive. There were treatment × time interactions (P<0.05) on plasma cortisol and haptoglobin concentrations as well as for total leukocyte and neutrophil concentrations in blood. Castration and dehorning increased cortisol concentrations and the effect of the procedures was additive (P<0.02). Dehorning alone elicited a greater (P<0.05) cortisol response than castration alone. In contrast, the leukocytosis and neutrophilia was greater (P<0.01) among castrated calves. In addition, haptoglobin concentrations at 24h after castration were elevated (P<0.01) in calves that were castrated. Both castration and dehorning suppressed (P=0.04) many leukocyte responses including the secretion of tumor necrosis factor-α when whole blood cultures were stimulated with lipopolysaccharide, surface expression of L-selectin on peripheral blood neutrophils, and the oxidative burst intensity of peripheral blood neutrophils when co-cultured with an Escherichia coli. The effects of castration and dehorning on blood leukocyte counts or any of the leukocyte responses were not additive (P>0.23). Castration and dehorning effects of plasma haptoglobin concentrations tended (P=0.10) to be additive at 72 h after the procedure(s). Prior administration of local anesthetic and a systemic analgesic attenuated (P<0.001) the cortisol response and prevented (P=0.03) the observed leukocytosis, neutrophilia, and leukocyte suppression. These data suggest that calves should be castrated and dehorned on the same day rather than spreading them out across two days and calves should be administered pain relief prior to performing either procedure. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Ultrasound-guided versus computed tomography-scan guided biopsy of pleural-based lung lesions

    PubMed Central

    Khosla, Rahul; McLean, Anna W; Smith, Jessica A

    2016-01-01

    Background: Computed tomography (CT) guided biopsies have long been the standard technique to obtain tissue from the thoracic cavity and is traditionally performed by interventional radiologists. Ultrasound (US) guided biopsy of pleural-based lesions, performed by pulmonologists is gaining popularity and has the advantage of multi-planar imaging, real-time technique, and the absence of radiation exposure to patients. In this study, we aim to determine the diagnostic accuracy, the time to diagnosis after the initial consult placement, and the complications rates between the two different modalities. Methods: A retrospective study of electronic medical records was done of patients who underwent CT-guided biopsies and US-guided biopsies for pleural-based lesions between 2005 and 2014 and the data collected were analyzed for comparing the two groups. Results: A total of 158 patients underwent 162 procedures during the study period. 86 patients underwent 89 procedures in the US group, and 72 patients underwent 73 procedures in the CT group. The overall yield in the US group was 82/89 (92.1%) versus 67/73 (91.8%) in the CT group (P = 1.0). Average days to the procedure was 7.2 versus 17.5 (P = 0.00001) in the US and CT group, respectively. Complication rate was higher in CT group 17/73 (23.3%) versus 1/89 (1.1%) in the US group (P < 0.0001). Conclusions: For pleural-based lesions the diagnostic accuracy of US guided biopsy is similar to that of CT-guided biopsy, with a lower complication rate and a significantly reduced time to the procedure. PMID:27625440

  3. Pre-procedure ultrasound-guided paramedian spinal anaesthesia at L5–S1: Is this better than landmark-guided midline approach? A randomised controlled trial

    PubMed Central

    Srinivasan, Karthikeyan Kallidaikurichi; Leo, Anne-Marie; Iohom, Gabriella; Loughnane, Frank; Lee, Peter J

    2018-01-01

    Background and Aims: Routine use of pre-procedural ultrasound guided midline approach has not shown to improve success rate in administering subarachnoid block. The study hypothesis was that the routine use of pre-procedural (not real time) ultrasound-guided paramedian spinals at L5-S1 interspace could reduce the number of passes (i.e., withdrawal and redirection of spinal needle without exiting the skin) required to enter the subarachnoid space when compared to the conventional landmark-guided midline approach. Methods: After local ethics approval, 120 consenting patients scheduled for elective total joint replacements (Hip and Knee) were randomised into either Group C where conventional midline approach with palpated landmarks was used or Group P where pre-procedural ultrasound was used to perform subarachnoid block by paramedian approach at L5-S1 interspace (real time ultrasound guidance was not used). Results: There was no difference in primary outcome (difference in number of passes) between the two groups. Similarly there was no difference in the number of attempts (i.e., the number of times the spinal needle was withdrawn from the skin and reinserted). The first pass success rates (1 attempt and 1 pass) was significantly greater in Group C compared to Group P [43% vs. 22%, P = 0.02]. Conclusion: Routine use of paramedian spinal anaesthesia at L5-S1 interspace, guided by pre-procedure ultrasound, in patients undergoing lower limb joint arthroplasties did not reduce the number of passes or attempts needed to achieve successful dural puncture. PMID:29416151

  4. New re-entry device for revascularization of chronic coronary total occlusions: preliminary single Japanese center experience.

    PubMed

    Tsuchikane, Etsuo; Kimura, Masashi; Suzuki, Takahiko; Habara, Maoto; Kurita, Tairo; Tanaka, Nobuyoshi; Nasu, Kenya; Ito, Tatsuya; Kinoshita, Yoshihisa; Wyman, R Michael

    2012-08-01

    Although retrograde approach for coronary chronic total occlusion (CTO) has been introduced, the procedure is still time and resource consuming. A simplified antegrade approach mightbe another resort. The aim of this study was to evaluate a new device designed to facilitate guidewire re-entry into the true lumen of a CTO from the adjacent subintimal space. Patients with CTO were entered into a prospective registry regardless of lesion characteristics. A new metal-tip catheter was used initially in primary use cases. If it created subintimal tracking, a new re-entry tool (a flat balloon with 2 exit ports offset by 180 degrees) was used as a platform to attempt guidewire penetration into the distal true lumen. In rescue use cases after unsuccessful conventional wiring, the re-entry procedure was subsequently attempted. In 11 CTO lesions attempted, device success was achieved in 8 cases (72.7%). Re-entry procedure success rate was higher in primary use cases (80%) compared to rescue use cases (33.3%). Retrograde approach was conducted immediately after unsuccessful antegrade procedure using this device in the other 3 cases and successful recanalization was achieved in all cases. All lesions were stented, resulting in TIMI 3 flow without major complications. A new coronary re-entry device may provide another strategic option in the antegrade approach to recanalize CTOs.

  5. Complications of Recanalization of Chronic Total Occlusion

    PubMed Central

    Kalyanasundaram, Arun; Lombardi, William L.

    2015-01-01

    Percutaneous Coronary Intervention (PCI) of Chronic Total Occlusions (CTO) is an accepted revascularization procedure. These complex procedures carry with them certain risks and potential complications. Complications of PCI such as contrast induced renal dysfunction, radiation, etc, assume more relevance given the length and complexity of these procedures. Further, certain complications such as donor vessel injury, foreign body entrapment are unique to CTO PCI. A thorough understanding of the potential complications is important in mitigating risk during these complex procedures.

  6. The clinical application of laparoscope-assisted peritoneal vaginoplasty for the treatment of congenital absence of vagina.

    PubMed

    Qin, Chenglu; Luo, Guangnan; Du, Min; Liao, Shi; Wang, Chunping; Xu, Keke; Tang, Jie; Li, Baoyan; Zhang, Juanjuan; Pan, Hongxin; Ball, Tyler W; Fang, Yujiang

    2016-06-01

    To evaluate the outcomes of laparoscope-assisted peritoneal vaginoplasty for the treatment of congenital vaginal atresia. A retrospective study enrolled patients diagnosed with congenital vaginal atresia who were treated with one of two different laparoscope-assisted peritoneal vaginoplasty techniques (named Luohu-one and Luohu-two) between October 31, 2001 and December 31, 2014. Operative time, intraoperative bleeding volume, surgical difficulty, complications, and post-procedure sexual satisfaction were reported. Data were collected for 620 patients. The Luohu-one procedure was used in the treatment of 145 patients, while 475 patients were treated with the Luohu-two procedure. In 5 (0.8%) patients, it was necessary to perform a sigmoid colon vaginoplasty. During surgery, 16 patients experienced a rectal injury, among whom, 9 patients experienced a rectal-vaginal fistula. Follow-up data extending to 7years were available for 285 patients. Of these 285 patients, 231 agreed to report details of their sexual experiences. In total, 222 (96.1%) patients reported being very satisfied with their vaginal conditions and sex life. The Luohu-two procedure demonstrated shorter operative and recovery time, and reduced intraoperative bleeding. However, both procedures demonstrated satisfactory results. Laparoscope-assisted peritoneal vaginoplasty demonstrated good safety and effectiveness in the treatment of patients with congenital vaginal atresia. Copyright © 2016 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  7. Feasibility of three-dimensional magnetic resonance angiography-fluoroscopy image fusion technique in guiding complex endovascular aortic procedures in patients with renal insufficiency.

    PubMed

    Schwein, Adeline; Chinnadurai, Ponraj; Shah, Dipan J; Lumsden, Alan B; Bechara, Carlos F; Bismuth, Jean

    2017-05-01

    Three-dimensional image fusion of preoperative computed tomography (CT) angiography with fluoroscopy using intraoperative noncontrast cone-beam CT (CBCT) has been shown to improve endovascular procedures by reducing procedure length, radiation dose, and contrast media volume. However, patients with a contraindication to CT angiography (renal insufficiency, iodinated contrast allergy) may not benefit from this image fusion technique. The primary objective of this study was to evaluate the feasibility of magnetic resonance angiography (MRA) and fluoroscopy image fusion using noncontrast CBCT as a guidance tool during complex endovascular aortic procedures, especially in patients with renal insufficiency. All endovascular aortic procedures done under MRA image fusion guidance at a single-center were retrospectively reviewed. The patients had moderate to severe renal insufficiency and underwent diagnostic contrast-enhanced magnetic resonance imaging after gadolinium or ferumoxytol injection. Relevant vascular landmarks electronically marked in MRA images were overlaid on real-time two-dimensional fluoroscopy for image guidance, after image fusion with noncontrast intraoperative CBCT. Technical success, time for image registration, procedure time, fluoroscopy time, number of digital subtraction angiography (DSA) acquisitions before stent deployment or vessel catheterization, and renal function before and after the procedure were recorded. The image fusion accuracy was qualitatively evaluated on a binary scale by three physicians after review of image data showing virtual landmarks from MRA on fluoroscopy. Between November 2012 and March 2016, 10 patients underwent endovascular procedures for aortoiliac aneurysmal disease or aortic dissection using MRA image fusion guidance. All procedures were technically successful. A paired t-test analysis showed no difference between preimaging and postoperative renal function (P = .6). The mean time required for MRA-CBCT image fusion was 4:09 ± 01:31 min:sec. Total fluoroscopy time was 20.1 ± 6.9 minutes. Five of 10 patients (50%) underwent stent graft deployment without any predeployment DSA acquisition. Three of six vessels (50%) were cannulated under image fusion guidance without any precannulation DSA runs, and the remaining vessels were cannulated after one planning DSA acquisition. Qualitative evaluation showed 14 of 22 virtual landmarks (63.6%) from MRA overlaid on fluoroscopy were completely accurate, without the need for adjustment. Five of eight incorrect virtual landmarks (iliac and visceral arteries) resulted from vessel deformation caused by endovascular devices. Ferumoxytol or gadolinium-enhanced MRA imaging and image fusion with fluoroscopy using noncontrast CBCT is feasible and allows patients with renal insufficiency to benefit from optimal guidance during complex endovascular aortic procedures, while preserving their residual renal function. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  8. What are the Risk Factors for Cerebrovascular Accidents After Elective Orthopaedic Surgery?

    PubMed

    Minhas, Shobhit V; Goyal, Preeya; Patel, Alpesh A

    2016-03-01

    Perioperative cerebrovascular accidents (CVAs) are one of the leading causes of patient morbidity, mortality, and medical costs. However, little is known regarding the rates of these events and risk factors for CVA after elective orthopaedic surgery. Our goals were to (1) establish the national, baseline proportion of patients experiencing a 30-day CVA and the timing of CVA; and (2) determine independent risk factors for 30-day CVA rates after common elective orthopaedic procedures. Patients undergoing elective TKA, THA, posterior or posterolateral lumbar fusion, anterior cervical discectomy and fusion, and total shoulder arthroplasty, from 2006 to 2012, were identified from the American College of Surgeons National Surgical Quality Improvement Program(®) database. A total of 42,150 patients met inclusion criteria. Thirty-day CVA rates were recorded for each procedure, and patients were assessed for characteristics associated with CVA through univariate analysis. Multivariate regression models were created to identify independent risk factors for CVA. A total of 55 (0.13%) patients experienced a CVA within 30 days of the procedure, occurring a median of 2 days after surgery (range, 1-30 days) with 0.08% of patients experiencing a CVA after TKA, 0.15% after THA, 0.00% after single-level anterior cervical discectomy and fusion, 0.38% after multilevel anterior cervical discectomy and fusions, 0.20% after single-level posterior or posterolateral lumbar fusion, 0.70% after multilevel posterior or posterolateral lumbar fusion, and 0.22% after total shoulder arthroplasty. Independent risk factors for CVA included age of 75 years or older (odds ratio [OR], 2.50; 95% CI, 1.44-4.35; p = 0.001), insulin-dependent diabetes mellitus (OR, 3.08; CI, 1.47-6.45; p = 0.003), hypertension (OR, 2.71; CI, 1.19-6.13; p = 0.017), history of transient ischemic attack (OR, 2.83; CI, 1.24-6.45; p = 0.013), dyspnea (OR, 2.51; CI, 1.30-4.86; p = 0.006), chronic obstructive pulmonary disease (OR, 2.33; CI, 1.06-5.13; p = 0.036), and operative time of 180 minutes or greater (OR, 3.25; CI 1.60-6.60; p = 0.001). Numerous nonmodifiable patient comorbidities and increased operative time were associated with CVA after elective orthopaedic procedures. However, the American College of Surgeons National Surgical Quality Improvement Program(®) database does not code for cardiac arrhythmia or atrial fibrillation, which other studies have suggested may be important predictor variables; those may be important risk factors, although we were unable to evaluate them in our study. Surgeons should counsel patients with these risk factors and limit their operative time to reduce the risk of these adverse events, and future studies should examine other patient characteristics such as arrhythmia and noncoronary heart disease and assess the role of pharmacologic prophylaxis in patients with these risk factors. Level III, prognostic study.

  9. Reduction of scatter radiation during transradial percutaneous coronary angiography: a randomized trial using a lead-free radiation shield.

    PubMed

    Politi, Luigi; Biondi-Zoccai, Giuseppe; Nocetti, Luca; Costi, Tiziana; Monopoli, Daniel; Rossi, Rosario; Sgura, Fabio; Modena, Maria Grazia; Sangiorgi, Giuseppe M

    2012-01-01

    Occupational radiation exposure is a growing problem due to the increasing number and complexity of interventional procedures performed. Radial artery access has reduced the number of complications at the price of longer procedure duration. Radpad® scatter protection is a sterile, disposable bismuth-barium radiation shield drape that should be able to decrease the dose of operator radiation during diagnostic and interventional procedures. Such radiation shield has never been tested in a randomized study in humans. Sixty consecutive patients undergoing coronary angiography by radial approach were randomized 1:1 to Radpad use versus no radiation shield protection. The sterile shield was placed around the area of right radial artery sheath insertion and extended medially to the patient trunk. All diagnostic procedures were performed by the same operator to reduce variability in radiation absorption. Radiation exposure was measured blindly using thermoluminescence dosimeters positioned at the operator's chest, left eye, left wrist, and thyroid. Despite similar fluoroscopy time (3.52 ± 2.71 min vs. 3.46 ± 2.77 min, P = 0.898) and total examination dose (50.5 ± 30.7 vs. 45.8 ± 18.0 Gycm(2), P = 0.231), the mean total radiation exposure to the operator was significantly lower when Radpad was utilized (282.8 ± 32.55 μSv vs. 367.8 ± 105.4 μSv, P < 0.0001) corresponding to a 23% total reduction. Moreover, mean radiation exposure was lower with Radpad utilization at all body locations ranging from 13 to 34% reduction. This first-in-men randomized trial demonstrates that Radpad significantly reduces occupational radiation exposure during coronary angiography performed through right radial artery access. Copyright © 2011 Wiley Periodicals, Inc.

  10. Open total gastrectomy with Roux-en-Y reconstruction for a chronic fistula after sleeve gastrectomy.

    PubMed

    Bruzzi, Matthieu; Douard, Richard; Voron, Thibault; Berger, Anne; Zinzindohoue, Franck; Chevallier, Jean-Marc

    2016-12-01

    Surgery appears to be the best treatment option for a chronic fistula after laparoscopic sleeve gastrectomy (LSG). Conservative procedures (conversion into a Roux-en-Y gastric bypass, Roux-limb placement) have proven their feasibility and efficacy, but an open total gastrectomy (TG) is sometimes required in challenging situations. To assess outcomes from 12 consecutive patients who underwent surgery for a post-sleeve gastrectomy chronic fistula (PSGCF) between January 2004 and February 2012. University public hospital, France. Patients with a PSGCF who underwent surgery were included in this retrospective study. Mortality, morbidity (i.e., Clavien-Dindo score), weight loss, and nutritional status were assessed. Twelve of 57 patients (21%) with a post-LSG leak developed a PSGCF. There were 3 men (25%). Mean age was 39±9 years and mean preoperative body mass index was 35±5 kg/m 2 . All 12 patients underwent an open total gastrectomy with an esojejunostomy (TG). Conservative procedures were considered but not possible. The mean follow-up period was 38±11 months. The mean delay between LSG and TG was 12±6 months. Intraoperative discovery of multiple (>2) gastric fistulas was reported in 9 patients (75%). There were no deaths, but morbidity rate was 50%. Early postoperative fistula occurred in 3 patients (anastomosis n = 1, duodenal stump n = 2). None of these patients required further surgery. The median healing time of the fistula was 37 days (range 24-53). Promising results from weight loss and nutritional status were found at the end of the follow-up. A salvage open TG is a well-tolerated and reproducible salvage procedure for cases of a PSGCF, when conservative procedures are not possible. Copyright © 2016 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  11. Rainfall, Streamflow, and Water-Quality Data During Stormwater Monitoring, Halawa Stream Drainage Basin, Oahu, Hawaii, July 1, 2006 to June 30, 2007

    USGS Publications Warehouse

    Young, Stacie T.M.; Jamison, Marcael T.J.

    2007-01-01

    Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. This program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream. For this program, rainfall data were collected at two stations, continuous streamflow data at three stations, and water-quality data at five stations, which include the two continuous streamflow stations. This report summarizes rainfall, streamflow, and water-quality data collected between July 1, 2006 and June 30, 2007. A total of 13 samples was collected over two storms during July 1, 2006 to June 30, 2007. The goal was to collect grab samples nearly simultaneously at all five stations and flow-weighted time-composite samples at the three stations equipped with automatic samplers. Samples were analyzed for total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, chromium, copper, lead, nickel, and zinc). Additionally, grab samples were analyzed for oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Quality-assurance/quality-control samples were also collected during storms and during routine maintenance to verify analytical procedures and check the effectiveness of equipment-cleaning procedures.

  12. Development and evaluation of an instrumented linkage system for total knee surgery.

    PubMed

    Walker, Peter S; Wei, Chih-Shing; Forman, Rachel E; Balicki, M A

    2007-10-01

    The principles and application of total knee surgery using optical tracking have been well demonstrated, but electromagnetic tracking may offer further advantages. We asked whether an instrumented linkage that attaches directly to the bone can maintain the accuracy of the optical and electromagnetic systems but be quicker, more convenient, and less expensive to use. Initial testing using a table-mounted digitizer to navigate a drill guide for placing pins to mount a cutting guide demonstrated the feasibility in terms of access and availability. A first version (called the Mark 1) instrumented linkage designed to fix directly to the bone was constructed and software was written to carry out a complete total knee replacement procedure. The results showed the system largely fulfilled these goals, but some surgeons found that using a visual display for pin placement was difficult and time consuming. As a result, a second version of a linkage system (called the K-Link) was designed to further develop the concept. User-friendly flexible software was developed for facilitating each step quickly and accurately while the placement of cutting guides was facilitated. We concluded that an instrumented linkage system could be a useful and potentially lower-cost option to the current systems for total knee replacement and could possibly have application to other surgical procedures.

  13. Pediatric patients on ketogenic diet undergoing general anesthesia-a medical record review.

    PubMed

    Soysal, Elif; Gries, Heike; Wray, Carter

    2016-12-01

    To identify guidelines for anesthesia management and determine whether general anesthesia is safe for pediatric patients on ketogenic diet (KD). Retrospective medical record review. Postoperative recovery area. All pediatric patients who underwent general anesthesia while on KD between 2009 and 2014 were reviewed. We identified 24 patients who underwent a total of 33 procedures. All children were on KD due to intractable epilepsy. The age of patients ranged from 1 to 15 years. General anesthesia for the scheduled procedures. Patients' demographics, seizure history, type of procedure; perioperative blood chemistry, medications including the anesthesia administered, and postoperative complications. Twenty-four patients underwent a total of 33 procedures. The duration of KD treatment at the time of general anesthesia ranged from 4 days to 8 years. Among the 33 procedures, 3 patients had complications that could be attributable to KD and general anesthesia. A 9-year-old patient experienced increased seizures on postoperative day 0. An 8-year-old patient with hydropcephalus developed metabolic acidosis on postoperative day 1, and a 7-year-old patient's procedure was complicated by respiratory distress and increased seizure activity in the postanesthesia care unit. This study showed that it is relatively safe for children on KD to undergo general anesthesia. The 3 complications attributable to general anesthesia were mild, and the increased seizure frequencies in 2 patients returned back to baseline in 24 hours. Although normal saline is considered more beneficial than lactated Ringer's solution in patients on KD, normal saline should also be administered carefully because of the risk of exacerbating patients' metabolic acidosis. One should be aware of the potential change of the ketogenic status due to drugs given intraoperatively. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Effectiveness of continuous improvement by a clinical pharmacist-led guidance team on the prophylactic antibiotics usage rationality in intervention procedure at a Chinese tertiary teaching hospital.

    PubMed

    Yang, Ping; Jiang, Sai-Ping; Lu, Xiao-Yang

    2017-01-01

    Irrational prophylactic antibiotics usage (PAU) during intervention procedures is common in China. A clinical pharmacist-led guidance team (CPGT) was established and participated in medical teams to advise on the rational usage of antibiotics. The objective of this study was to assess the effectiveness of CPGT intervention for the rationality of PAU during intervention procedures. This was a retrospective cross-sectional study with three stages at a Chinese tertiary teaching hospital. Patients who received some specific intervention procedures in the first quarter of 2015 were enrolled as the preintervention group, while those who received the procedures in the second and third quarters of 2015 were enrolled as the postintervention group. CPGT established the criteria for the PAU and conducted the intervention. The pre- and postintervention groups were then compared to evaluate the effectiveness of CPGTs' sustained interventions. A total of 651 patients were enrolled, with 200 patients in the preintervention group, while 233 patients and 218 patients in the first- and second-intervention groups, respectively. With the implementation of CPGTs continuous intervention, the rationality of PAU was significantly improved, including the timing (91.98% vs 97.74%, P =0.015), duration (82.72% vs 98.31%, P <0.0001), and choice (81.48% vs 93.22%, P =0.001) of antibiotics administered during perioperative period. Moreover, the cost of total (US$34.89±80.96 vs US$9.81±26.31, P =0.025) and inappropriate PAU (US$28.75±73.27 vs US$3.57±14.62, P <0.0001) per patient was significantly reduced. CPGTs' continuous intervention significantly improved the rationality of PAU during intervention procedures, with a significant reduction in antibiotic cost.

  15. Comparison of Healthcare Costs Among Commercially Insured Women in the United States Who Underwent Hysteroscopic Sterilization Versus Laparoscopic Bilateral Tubal Ligation Sterilization.

    PubMed

    Carney, Patricia I; Yao, Jianying; Lin, Jay; Law, Amy

    2017-05-01

    This study evaluated healthcare costs of index procedures and during a 6-month follow-up of women who had hysteroscopic sterilization (HS) versus laparoscopic bilateral tubal ligation (LBTL). Women (18-49 years) with claims for HS and LBTL procedures were identified from the MarketScan commercial claims database (January 1, 2010, to December 31, 2012) and placed into separate cohorts. Demographics, characteristics, index procedure costs, and 6-month total healthcare costs and sterilization procedure-related costs were compared. Multivariable regression analyses were used to examine the impact of HS versus LBTL on costs. Among the study population, 12,031 had HS (mean age: 37.0 years) and 7286 had LBTL (mean age: 35.8 years). The majority (80.9%) who had HS underwent the procedure in a physician's office setting. Fewer women who had HS versus LBTL received the procedure in an inpatient setting (0.5% vs. 2.1%), an ambulatory surgical center setting (5.0% vs. 23.8%), or a hospital outpatient setting (13.4% vs. 71.9%). Mean total cost for the index sterilization procedure was lower for HS than for LBTL ($3964 vs. $5163, p < 0.0001). During the 6-month follow-up, total medical and prescription costs for all causes ($7093 vs. $7568, p < 0.0001) and sterilization procedure-related costs ($4971 vs. $5407, p < 0.0001) were lower for women who had HS versus LBTL. Multivariable regression results confirmed that costs were lower for women who had HS versus LBTL. Among commercially insured women in the United States, HS versus LBTL is associated with lower average costs for the index procedure and lower total healthcare and procedure-related costs during 6 months after the sterilization procedure.

  16. Robotic Cholecystectomy Using the Newly Developed Korean Robotic Surgical System, Revo-i: A Preclinical Experiment in a Porcine Model.

    PubMed

    Kang, Chang Moo; Chong, Jae Uk; Lim, Jin Hong; Park, Dong Won; Park, Sung Jun; Gim, Suhyeon; Ye, Hye Jin; Kim, Se Hoon; Lee, Woo Jung

    2017-09-01

    One Korean company recently successfully produced a robotic surgical system prototype called Revo-i (MSR-5000). We, therefore, conducted a preclinical study for robotic cholecystectomy using Revo-i, and this is a report of the first case of robotic cholecystectomy performed using the Revo-i system in a preclinical porcine model. Revo-i consists of a surgeon console (MSRC-5000), operation cart (MSRO-5000) and vision cart (MSRV-5000), and a 40 kg-healthy female porcine was prepared for robotic cholecystectomy with general anesthesia. The primary end point was the safe completion of these procedures using Revo-i: The total operation time was 88 minutes. The dissection time was defined as the time from the initial dissection of the Calot area to the time to complete gallbladder detachment from the liver bed: The dissection time required 14 minutes. The surgical console time was 45 minutes. There was no gallbladder perforation or significant bleeding noted during the procedure. The porcine survived for two weeks postoperatively without any complications. Like the da Vinci surgical system, the Revo-i provides a three-dimensional operative view and allows for angulated instrument motion (forceps, needle-holders, clip-appliers, scissors, bipolar energy, and hook monopolar energy), facilitating an effective laparoscopic procedure. Our experience suggests that robotic cholecystectomy can be safely completed in a porcine model using Revo-i. © Copyright: Yonsei University College of Medicine 2017.

  17. Effect of Music on Outpatient Urological Procedures: A Systematic Review and Meta-Analysis from the European Association of Urology Section of Uro-Technology.

    PubMed

    Kyriakides, Rena; Jones, Patrick; Geraghty, Robert; Skolarikos, Andreas; Liatsikos, Evangellos; Traxer, Olivier; Pietropaolo, Amelia; Somani, Bhaskar K

    2018-05-01

    Music is a practical, inexpensive and harmless analgesic and anxiolytic. An increasing number of original studies have been performed to investigate its potential application in urology. Our aim was to identify the effect of music on outpatient based urological procedures. We systematically reviewed the effect of using music during all reported outpatient urology procedures, including transrectal ultrasound guided prostate biopsy, shock wave lithotripsy, urodynamic studies, percutaneous nephrostomy tube placement and cystoscopy. Data were included on all randomized trials from 1980 to 2017 and no language restrictions were applied. Included in analysis were 16 randomized studies in which 972 of 1,950 patients (49.8%) were exposed to music during an outpatient procedure. The procedures included transrectal ultrasound guided prostate biopsy in 4 studies in a total of 286 patients, shock wave lithotripsy in 6 studies in a total of 1,023, cystoscopy in 3 studies in a total of 331, urodynamics in 2 studies in a total of 210 and percutaneous nephrostomy in 1 study in a total of 100. All studies incorporated a visual analog score to measure pain. Anxiety was measured by STAI (State-Trait Anxiety Inventory) in 13 studies and by a visual analog scale in 2. While 14 of the 16 studies showed a reduction in self-reported pain, a reduction in anxiety was seen in 14. When using music, overall procedural satisfaction was better in 9 studies and patient willingness to repeat the procedure was also higher in 7. Our meta-analysis revealed a significant reduction in visual analog scale and STAI findings across all studies (p <0.001). Our systematic review demonstrated a beneficial effect of music on urological outpatient procedures. Music seemed to decrease anxiety and pain. It might serve as a useful adjunct to increase procedural satisfaction and patient willingness to undergo the procedure again. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  18. Development of extraction procedure for determination of mercury species using SPME-assisted dispersive derivative agent

    NASA Astrophysics Data System (ADS)

    Abdullah, Md Pauzi; Khalik, Wan Mohd Afiq Wan Mohd; Othman, Mohamed Rozali

    2016-11-01

    The extraction procedure for determination of low level mercury using solid phase microextraction was successfully carried out. Design of experimental works using factorial design and central composite design were applied to screen and predict the optimum condition for extraction step. In this study, variables namely concentration level (5 % m/v) and volume of derivatization solution (150 µL) has depicted as main effect for controlling the suitability of derivative reagent condition. Maximum of signal response (account as total peak areas for mercury species) was obtained when extraction procedure was set up at pH of water sample (5.8), extraction time (14 min), extraction temperature (43 °C) and stirring rate (450 rpm). Reducing time required to reach equilibrium is new improvement achieved in this study. Detection limit for each species (MeHg 26.17 ngL-1; EtHg 48.84 ngL-1 and IHg 14.11 ngL-1) was calculated lower than our previous work. Recovery, repeatability and reproducibility trial were recorded varied at acceptable range and relative standard deviation was calculated below than 10 %.

  19. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE--COMPENDIUM OF METHODS FOR ANALYSIS OF TRACE METALS AND PESTICIDES IN DIETARY SAMPLES USING TOTAL DIET STUDY PROCEDURES (FDA-COMPENDIUM)

    EPA Science Inventory

    This compendium contains seven SOPs developed by Food and Drug Administration (FDA) laboratories for methods of analyzing trace metals in dietary samples collected using Total Diet study procedures. The SOPs include the following: (1) Quality Control for Analysis of NHEXAS Food o...

  20. [Urologic surgical procedures in patients with uterus neoplasm and colon-rectal cancer].

    PubMed

    Marino, G; Laudi, M; Capussotti, L; Zola, P

    2008-01-01

    INTRODUCTION. During the last 30 years, the multidisciplinary treatments of colon and uterus neoplasm have yielded an increase in total survival rates, fostering therefore the increase of cases with regional relapse involving the urinary tract. In these cases the iterative surgery can be performed, if no disease secondary to pelvic pain, haemostatic or debulking procedure is present, and must be considered and discussed with the patient, according to his/her general status. MATERIALS AND METHODS. From 1997 to August 2007 we performed altogether 43 pelvic iterative surgeries, with simultaneous urologic surgical procedure because of pelvic tumor relapse in patients with uterus neoplasm and colon and rectal cancer. In 4 cases of anal cancer, the urological procedure were: one radical prostatectomy with continent vesicostomy in the first case, while in the other 3 cases radical pelvectomy with double-barrelled uretero-cutaneostomy. In 23 cases of colon cancer, the urologic procedures were: 9 cases of radical cystectomy with double-barrelled uretero-cutaneostomy, 4 cases of radical cystectomy with uretero-ileo-cutaneostomy according to Bricker- Wallace II procedure, and 9 cases of partial cystectomy with pelvic ureterectomy and ureterocystoneostomy according to Lich-Gregoire technique (7 cases) and Lembo-Boari (2 cases) procedure. In 16 cases of uterus cancer, the urological procedure were: 7 cases of partial cystectomy with pelvic ureterectomy and uretero-cystoneostomy according to Lich-Gregoire procedure; in 3 cases, a radical cystectomy with urinary continent cutaneous diversion according to the Ileal T-pouch procedure; 2 cases of total pelvectomy and double uretero-cutaneostomy, and 4 cases of bilateral uretero-cutaneostomy. RESULTS. No patients died in the perioperative time; early systemic complications were: 2 esophageal candidiasis, 1 case of venous thrombosis. CONCLUSIONS. The iterative pelvic surgery in the case of oncological relapse involving the urinary tract aims to achieve the best quality of life with the utmost oncological radicality. The equation: eradication of pelvic neoplasm and urinary tract reconstruction, with acceptable quality of life, will be the future target; nevertheless, it is not possible to establish guidelines beforehand, and the therapy must be adapted to each single case.

  1. Horizontal ridge reconstruction of the anterior maxilla using customized allogeneic bone blocks with a minimally invasive technique - a case series.

    PubMed

    Venet, Laurent; Perriat, Michel; Mangano, Francesco Guido; Fortin, Thomas

    2017-12-08

    Different surgical procedures have been proposed to achieve horizontal ridge reconstruction of the anterior maxilla; all these procedures, however, require bone replacement materials to be adapted to the bone defect at the time of implantation, resulting in complex and time-consuming procedures. The purpose of this study was to describe how to use a 3D printed hardcopy model of the maxilla to prepare customized milled bone blocks, to be adapted on the bone defect areas using a minimally invasive subperiosteal tunneling technique. Cone beam computed tomography (CBCT) images of the atrophic maxilla of six patients were acquired and modified into 3D reconstruction models. Data were transferred to a 3D printer and solid models were fabricated using autoclavable nylon polyamide. Before the surgery, freeze-dried cortico-cancellous blocks were manually milled and adapted on the 3D printed hardcopy models of the maxillary bone, in order to obtain customized allogeneic bone blocks. In total, eleven onlay customized allogeneic bone grafts were prepared and implanted in 6 patients, using a minimally invasive subperiosteal tunneling technique. The scaffolds closely matched the shape of the defects: this reduced the operation time and contributed to good healing. The patients did not demonstrate adverse events such as inflammation, dehiscence or flap re-opening during the recovery period; however, one patient experienced scaffold resorption, which was likely caused by uncontrolled motion of the removable provisional prosthesis. Following a 6 month healing period, CBCT was used to assess graft integration, which was followed by insertion of implants into the augmented areas. Prosthetic restorations were placed 4 months later. These observations suggest that customized bone allografts can be successfully used for horizontal ridge reconstruction of the anterior maxilla: patients demonstrated reduced morbidity and decreased total surgery time. Further studies on a larger sample of patients, with histologic evaluation and longer follow-up are needed to confirm the present observations.

  2. The Arrival of Robotics in Spine Surgery: A Review of the Literature.

    PubMed

    Ghasem, Alexander; Sharma, Akhil; Greif, Dylan N; Alam, Milad; Maaieh, Motasem Al

    2018-04-18

    Systematic Review. The authors aim to review comparative outcome measures between robotic and free-hand spine surgical procedures including: accuracy of spinal instrumentation, radiation exposure, operative time, hospital stay, and complication rates. Misplacement of pedicle screws in conventional open as well as minimally invasive surgical procedures has prompted the need for innovation and allowed the emergence of robotics in spine surgery. Prior to incorporation of robotic surgery in routine practice, demonstration of improved instrumentation accuracy, operative efficiency, and patient safety is required. A systematic search of the PubMed, OVID-MEDLINE, and Cochrane databases was performed for papers relevant to robotic assistance of pedicle screw placement. Inclusion criteria were constituted by English written randomized control trials, prospective and retrospective cohort studies involving robotic instrumentation in the spine. Following abstract, title, and full-text review, 32 articles were selected for study inclusion. Intrapedicular accuracy in screw placement and subsequent complications were at least comparable if not superior in the robotic surgery cohort. There is evidence supporting that total operative time is prolonged in robot assisted surgery compared to conventional free-hand. Radiation exposure appeared to be variable between studies; radiation time did decrease in the robot arm as the total number of robotic cases ascended, suggesting a learning curve effect. Multi-level procedures appeared to tend toward earlier discharge in patients undergoing robotic spine surgery. The implementation of robotic technology for pedicle screw placement yields an acceptable level of accuracy on a highly consistent basis. Surgeons should remain vigilant about confirmation of robotic assisted screw trajectory, as drilling pathways have been shown to be altered by soft tissue pressures, forceful surgical application, and bony surface skiving. However, the effective consequence of robot-assistance on radiation exposure, length of stay, and operative time remains unclear and requires meticulous examination in future studies. 4.

  3. Resident involvement in laparoscopic procedures does not worsen clinical outcomes but may increase operative times and length of hospital stay.

    PubMed

    Jolley, Jennifer; Lomelin, Daniel; Simorov, Anton; Tadaki, Carl; Oleynikov, Dmitry

    2016-09-01

    Surgical procedures have a learning curve regarding the number of cases required for proficiency. Consequently, involvement of less experienced resident surgeons may impact patients and the healthcare system. This study examines basic and advanced laparoscopic procedures performed between 2010 and 2011 and evaluates the resident surgeon participation effect. Basic laparoscopic procedures (BL), appendectomy (LA), cholecystectomy (LC), and advanced Nissen fundoplication (LN) were queried from the American College of Surgeons National Surgical Quality Improvement Program database. Cases were identified using Current Procedural Terminology codes. Analyses were performed using IBM SPSS Statistics v.22, α-level = 0.05. Multiple logistic regression was used, accounting for age, race, gender, admission status, wound classification, and ASA classification. In total, 71,819 surgeries were reviewed, 66,327 BL (37,636 LC and 28,691 LA) and 5492 LN. Median age was 48 years for LC and 37 years for LA. In sum, 72.2 % of LC and 49.5 % of LA patients were female. LN median age was 59 years, and 67.7 % of patients were female. For BL, resident involvement was not significantly associated with mortality, morbidity, and return to the OR. Readmission was not related to resident involvement in LC. In LA, resident-involved surgeries had increased readmission and longer OR time, but decreased LOS. In LC, resident involvement was associated with longer LOS and OR time. Resident involvement was not a significant factor in the odds of mortality, morbidity, return to OR, or readmission in LN. Surgeries involving residents had increased odds of having longer LOS, and of lengthier surgery time. We demonstrate resident involvement is safe and does not result in poorer patient outcomes. Readmissions and LOS were higher in BL, and operative times were longer in all surgeries. Resident operations do appear to have real consequences for patients and may impact the healthcare system financially.

  4. A Retrospective Audit of Dental Treatment Provided to Special Needs Patients under General Anesthesia During a Ten-Year Period.

    PubMed

    Mallineni, Sreekanth Kumar; Yiu, Cynthia Kar Y

    The purpose of this study was to perform a comprehensive audit of dental treatment provided to special needs patients (SNP) under general anesthesia (GA) over a ten-year period. Special needs patients who received dental treatment under GA as an in-patient at Queen Mary Hospital, Hong Kong SAR during the time period January 2002 and December 2011 were included in the study. The study population was divided into three groups, based on age (<6years, 6-12 years, >12 years). One-way ANOVA was used to evaluate the effect of "age group" on duration of treatment, post-recovery time, treatment procedures and utilization of different restorative materials. Kappa statistics were used for intra-examiner reliability. A total of 275 patients (174 males and 101 females) were included in the study. The mean age of the patients at the time they received GA was 12.37±10.18 years. Dental procedures performed were mostly restorative in nature (47%). The >12 years group had significantly shorter treatment duration (p<0.05). No significant difference in post-operative recovery time was observed among the three age groups (p>0.05). The <6 years group received significantly less preventive, but more restorative procedures (p<0.05). Significantly fewer extractions were performed in the 6-12 years group (p<0.05). The use of composite restorations was significantly higher in the <6 years group; while amalgam restorations were more frequently used in the >12 years group (P<0.05). Stainless steel crowns were more frequently employed in SNP under 12 years of age (p<0.05). Intra-examiner reliability was good (k=0.94). Most of the dental procedures performed under GA on SNP were restorative procedures. For children less than 6 years of age, had longer treatment time under GA. Composite restorations and stainless steel crowns were more frequently used in the primary dentition and amalgam restorations were more frequently employed in the permanent dentition.

  5. Access to specialist gastroenterology care in Canada: The Practice Audit in Gastroenterology (PAGE) Wait Times Program

    PubMed Central

    Armstrong, David; Barkun, Alan NG; Chen, Ying; Daniels, Sandra; Hollingworth, Roger; Hunt, Richard H; Leddin, Desmond

    2008-01-01

    BACKGROUND: Canadian wait time data are available for the treatment of cancer and heart disease, as well as for joint replacement, cataract surgery and diagnostic imaging procedures. Wait times for gastroenterology consultation and procedures have not been studied, although digestive diseases pose a greater economic burden in Canada than cancer or heart disease. METHODS: Specialist physicians completed the practice audit if they provided digestive health care, accepted new patients and recorded referral dates. For patients seen for consultation or investigation over a one-week period, preprogrammed personal digital assistants were used to collect data including the main reason for referral, initial referral and consultation dates, procedure dates (if performed), personal and family history, and patient symptoms, signs and test results. Patient triaging, appropriateness of the referral and timeliness of care were noted. RESULTS: Over 10 months, 199 physicians recorded details of 5559 referrals, including 1903 visits for procedures. The distribution of total wait times (from referral to procedure) nationally was highly skewed at 91/203 days (median/75th percentile), with substantial interprovincial variation: British Columbia, 66/185 days; Alberta, 134/284 days; Ontario, 110/208 days; Quebec, 71/149 days; New Brunswick, 104/234 days; and Nova Scotia, 42/84 days. The percentage of physicians by province offering average-risk screening colonoscopy varied from 29% to 100%. DISCUSSION: Access to specialist gastroenterology care in Canada is limited by long wait times, which exceed clinically reasonable waits for specialist treatment. Although exhibiting some methodological limitations, this large practice audit sampling offers broadly generalized results, as well as a means to identify barriers to health care delivery and evaluate strategies to address these barriers, with the goals of expediting appropriate care for patients with digestive health disorders and ameliorating the personal and societal burdens imposed by digestive diseases. PMID:18299734

  6. Use of Concomitant Stress Incontinence Surgery at Time of Pelvic Organ Prolapse Surgery Since Release of the 2011 Notification on Serious Complications Associated with Transvaginal Mesh.

    PubMed

    Drain, Alice; Khan, Aqsa; Ohmann, Erin L; Brucker, Benjamin M; Smilen, Scott; Rosenblum, Nirit; Nitti, Victor W

    2017-04-01

    There is controversy regarding the performance of concomitant anti-incontinence procedures at the time of pelvic organ prolapse repair. Data support improvement in stress urinary incontinence with a concomitant sling but increased adverse events. We assessed trends in preoperative stress urinary incontinence evaluation, concomitant anti-incontinence procedure at pelvic organ prolapse surgery and postoperative anti-incontinence procedures at our institution before and after the 2011 FDA (U.S. Food and Drug Administration) Public Health Notification pertaining to vaginal mesh. We retrospectively reviewed the records of patients who underwent pelvic organ prolapse surgery from 2009 to 2015. Preoperative workup included assessment of subjective stress urinary incontinence and/or evaluation for leakage with reduction of pelvic organ prolapse on physical examination, urodynamics or a pessary trial. The percentages of concomitant and postoperative anti-incontinence procedures were compared before and after the 2011 FDA notification. A total of 775 women underwent pelvic organ prolapse repair. The percentage of anti-incontinence procedures at pelvic organ prolapse repair decreased from 54.8% to 38.0% after the FDA notification (p = 0.002) while the incidence of preoperative objective stress urinary incontinence on examination, urodynamics and pessary trials remained constant. The incidence of postoperative anti-incontinence procedures within 1 year of the index surgery remained low. We found a decrease in the incidence of concomitant anti-incontinence procedures at the time of pelvic organ prolapse repair following the 2011 FDA notification despite no significant decline in subjective stress urinary incontinence or demonstrable stress urinary incontinence on preoperative evaluation. Further analysis is warranted to assess the impact of the FDA notification on treatment patterns in women with pelvic organ prolapse and stress urinary incontinence. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  7. Measuring the value of endoscopic retrograde cholangiopancreatography activity: an opportunity to stratify endoscopists on the basis of their value.

    PubMed

    Parihar, Vikrant; Moran, Carthage; Maheshwari, Pardeep; Cheriyan, Danny; O'Toole, Aoibhlinn; Murray, Frank; Patchett, Stephen E; Harewood, Gavin C

    2018-07-01

    As finite healthcare resources come under pressure, the value of physician activity is assuming increasing importance. The value in healthcare can be defined as patient health outcomes achieved per monetary unit spent. Even though some attempts have been made to quantify the value of clinician activity, there is little in the medical literature describing the importance of endoscopists' activity. This study aimed to characterize the value of endoscopic retrograde cholangiopancreatography (ERCP) performance of five gastroenterologists. We carried out a retrospective-prospective cohort study using the databases of patients undergoing ERCP between September 2014 and March 2017. We collected data from 1070 patients who underwent ERCP comparing value among the ERCPists at index ERCP. Procedure value was calculated using the formula Q/(T/C), where Q is the quality of procedure, T is the duration of procedure and C is the adjusted for complexity level. Quality and complexity were derived on a 1-4 Likert scale on the basis of American Society for Gastrointestinal Endoscopy criteria; time was recorded (in min) from intubation to extubation. Endoscopist time calculated from procedure time was considered a surrogate marker of cost as individual components of procedure cost were not itemized. In total, 590 procedures were analysed: 465 retrospectively over 24 months and 125 prospectively over 6 months. There was a 32% variation in the value of endoscopist activity in a more substantial retrospective cohort, with an even more considerable 73% variation in a smaller prospective arm. In an analysis of greater than 1000 ERCPs by a small cohort of experienced ERCPists, there was a wide variation in the value of endoscopist activity. Although the precision of estimating procedural costs needs further refinement, these findings show the ability to stratify ERCPists on the basis of the value their activity. As healthcare costs are scrutinized more closely, such value measurements are likely to become more relevant.

  8. Local versus general anesthesia for transcatheter aortic valve implantation (TAVR)--systematic review and meta-analysis.

    PubMed

    Fröhlich, Georg M; Lansky, Alexandra J; Webb, John; Roffi, Marco; Toggweiler, Stefan; Reinthaler, Markus; Wang, Duolao; Hutchinson, Nevil; Wendler, Olaf; Hildick-Smith, David; Meier, Pascal

    2014-03-10

    The hypothesis of this study was that local anesthesia with monitored anesthesia care (MAC) is not harmful in comparison to general anesthesia (GA) for patients undergoing Transcatheter Aortic Valve Implantation (TAVR).TAVR is a rapidly spreading treatment option for severe aortic valve stenosis. Traditionally, in most centers, this procedure is done under GA, but more recently procedures with MAC have been reported. This is a systematic review and meta-analysis comparing MAC versus GA in patients undergoing transfemoral TAVR. Trials were identified through a literature search covering publications from 1 January 2005 through 31 January 2013. The main outcomes of interest of this literature meta-analysis were 30-day overall mortality, cardiac-/procedure-related mortality, stroke, myocardial infarction, sepsis, acute kidney injury, procedure time and duration of hospital stay. A random effects model was used to calculate the pooled relative risks (RR) with 95% confidence intervals. Seven observational studies and a total of 1,542 patients were included in this analysis. None of the studies were randomized. Compared to GA, MAC was associated with a shorter hospital stay (-3.0 days (-5.0 to -1.0); P = 0.004) and a shorter procedure time (MD -36.3 minutes (-58.0 to -15.0 minutes); P <0.001). Overall 30-day mortality was not significantly different between MAC and GA (RR 0.77 (0.38 to 1.56); P = 0.460), also cardiac- and procedure-related mortality was similar between both groups (RR 0.90 (0.34 to 2.39); P = 0.830). These data did not show a significant difference in short-term outcomes for MAC or GA in TAVR. MAC may be associated with reduced procedural time and shorter hospital stay. Now randomized trials are needed for further evaluation of MAC in the setting of TAVR.

  9. The Use of Intraservice Work per Unit of Time (IWPUT) and the Building Block Method (BBM) for the Calculation of Surgical Work

    PubMed Central

    Mabry, Charles D.; McCann, Barton C.; Harris, Jean A.; Martin, Janet; Gage, John O.; Fischer, Josef E.; Opelka, Frank G.; Zwolak, Robert; Borman, Karen; Preskitt, John T.; Collicott, Paul E.; McGinnis, LaMar; Cohn, Isidore

    2005-01-01

    Objective: We will review the contribution to the Medicare Fee Schedule (MFS) by the techniques of intensity of work per unit of time (IWPUT), the building block methodology (BBM), and the work accomplished by the American College of Surgeons General Surgery Coding & Reimbursement Committee (GSCRC) in using IWPUT/BBM to detect undervalued surgical procedures and recommend payment increases. Summary Background Data: The MFS has had a major impact on surgeons’ income since its introduction in 1992 by the Centers for Medicare and Medicaid (CMS) and additionally has been adopted for use by many commercial insurers. A major component of MFS is physician work, measured as the relative value of work (RVW), which has 2 components: time and intensity. These components are incorporated by: RVW = time × intensity. Methods: This work formula can be rearranged to give the IWPUT, which has become a powerful tool to calculate the amount of RVW performed by physicians. Most procedures are valued by the total RVW in the global surgical package, which includes pre-, intra-, and postoperative care for a time after surgery. Summing these perioperative components into RVW is called the building block methodology (BBM). Results: Using these techniques, the GSCRC increased the values for 314 surgery procedures during a recent CMS 5-year review, resulting in an increase to general surgeons of roughly $76 million annually. Conclusions: The use of IWPUT/BBM has been instrumental to correct payment for undervalued surgical procedures. They are powerful methods to measure RVW across specialties and to solve reimbursement, compensation, and practice management problems facing surgeons. PMID:15912042

  10. Intrarenal Surgery vs Percutaneous Nephrolithotomy in the Management of Lower Pole Stones Greater than 2 cm.

    PubMed

    Koyuncu, Hakan; Yencilek, Faruk; Kalkan, Mehmet; Bastug, Yavuz; Yencilek, Esin; Ozdemir, Ahmet Tunc

    2015-01-01

    To compare the efficacy of RIRS and PNL in lower pole stones ≥ 2 cm. Materials and and Methods: A total of 109 patients who underwent PNL or RIRS for solitary lower pole stone between April 2009 and December 2012, were retrospectively analyzed. Lower pole stone was diagnosed with CT scan. Stone size was assessed as the longest axis of the stone. All patients were informed about the advantages, disadvantages and probable complications of both PNL and RIRS before the selection of the procedure. Patients decided the surgery type by themselves without being under any influences and written informed consent was obtained from all patients prior to the surgery. Patients were divided into two groups according to the patients' preference of surgery type. Group 1 consisted of 77 patients who underwent PNL and Group 2 consisted of 32 patients treated with RIRS. Stone free statuses, postoperative complications, operative time and hospitalization time were compared in both groups. There was no statistical significance between the two groups in mean age, stone size, stone laterality, mean follow-up periods and mean operative times. In PNL group, stone-free rate was 96.1% at first session and 100% after the additional procedure. In Group 2, stone-free rate was 90.6% at the first procedure and 100% after the additional procedure. The final stone-free rates and operative times were similar in both groups. RIRS should be an effective treatment alternative to PNL in lower pole stones larger than 2 cm, especially in selected patients.

  11. Intrarenal Surgery vs Percutaneous Nephrolithotomy in the Management of Lower Pole Stones Greater than 2 cm

    PubMed Central

    Koyuncu, Hakan; Yencilek, Faruk; Kalkan, Mehmet; Bastug, Yavuz; Yencilek, Esin; Ozdemir, Ahmet Tunc

    2015-01-01

    Purpose To compare the efficacy of RIRS and PNL in lower pole stones ≥2 cm. Materials and and Methods: A total of 109 patients who underwent PNL or RIRS for solitary lower pole stone between April 2009 and December 2012, were retrospectively analyzed. Lower pole stone was diagnosed with CT scan. Stone size was assessed as the longest axis of the stone. All patients were informed about the advantages, disadvantages and probable complications of both PNL and RIRS before the selection of the procedure. Patients decided the surgery type by themselves without being under any influences and written informed consent was obtained from all patients prior to the surgery. Patients were divided into two groups according to the patients’ preference of surgery type. Group 1 consisted of 77 patients who underwent PNL and Group 2 consisted of 32 patients treated with RIRS. Stone free statuses, postoperative complications, operative time and hospitalization time were compared in both groups. Results There was no statistical significance between the two groups in mean age, stone size, stone laterality, mean follow-up periods and mean operative times. In PNL group, stone-free rate was 96.1% at first session and 100% after the additional procedure. In Group 2, stone-free rate was 90.6% at the first procedure and 100% after the additional procedure. The final stone-free rates and operative times were similar in both groups. Conclusions RIRS should be an effective treatment alternative to PNL in lower pole stones larger than 2 cm, especially in selected patients. PMID:26005965

  12. The application of surgical procedure manager (SPM): first experience with FESS.

    PubMed

    Feige, Katharina; Gollnick, Iris; Schmitz, Pia; Strauss, Gero

    2017-09-01

    In our hypothesis, the newly developed program SPM (surgical procedure manager) will ensure successful standardization and efficiency of the FESS (functional endoscopic sinus surgery) and therefore make a decisive contribution in terms of economization and improvement of intraoperative quality. Between 27th March 2015 and 8th October 2015, data from 259 FESS procedures were collected using the SPM. The study took place at the surgical desk, an operating room in the ACQUA clinic in Leipzig, Germany. 233 FESS (90%) of the total FESS (n = 259, 100%) were conducted entirely with SPM. 26 SPM terminations (10%) of 259 FESS remain, which are classified as actual SPM terminations-when the surgeon intentionally stops the SPM. The maximum time slot decreased clearly from 1 h 39 min (period A) to 1 h 10 min (period B). A time reduction can also be seen with the minimum duration of 13.5 min compared to 11 min. The variability of the time slot also decreases since the standard deviation is reduced by 4.5 min. On the basis of available recordings it can be postulated that the application of SPM is suitable for standardization for FESS. Standardization by means of SPM and minimal development can be recognized over a period of time. The SPM makes it possible to transfer the general advantages of mechanization on a concrete FESS and do not influence the medical processes nor even restrict the medical freedom. The users are still entirely free in the implementation of the respective procedure.

  13. Administration order of midazolam/fentanyl for moderate dental sedation

    PubMed Central

    2018-01-01

    Background The purpose of this study is to investigate the effects of administration order when a sedative drug (midazolam) and an opioid analgesic drug (fentanyl) is applied for moderate intravenous (IV) sedation in dentistry. Methods A retrospective chart review was conducted in one dental clinic during its transition from a midazolam-first to a fentanyl-first protocol for dental procedures requiring moderate IV sedation. Physiological parameters, drug administration times, patient recovery times, drug dosages, and patient recall and satisfaction were investigated for differences. Results A total of 76 charts (40 midazolam-first and 36 fentanyl-first administrations), were used in the analysis. Administering midazolam first resulted in an average 4.38 min (52%) decrease in administration times (P < 0.001), and a decrease in procedural recollection immediately following the procedure (P = 0.03), and 24 to 48 hours later (P = 0.009). Administering fentanyl first required an average of 2.43 mg (29%) less midazolam (P < 0.001). No significant differences were found for change in vital signs, minimum oxygen saturation levels, recovery times, and patient satisfaction (P > 0.05). Oxygen saturation levels did not drop below 90% for either group; however, 5 cases in the fentanyl-first group fell to between 90% and 92%, compared with 0 cases in the midazolam-first group. Conclusions The administration order of fentanyl and midazolam may have different effects on patients and the sedation procedure. Findings from this study should be used to facilitate discussion among dental practitioners and to guide additional research investigating this topic. PMID:29556559

  14. Imaging System for Vaginal Surgery.

    PubMed

    Taylor, G Bernard; Myers, Erinn M

    2015-12-01

    The vaginal surgeon is challenged with performing complex procedures within a surgical field of limited light and exposure. The video telescopic operating microscope is an illumination and imaging system that provides visualization during open surgical procedures with a limited field of view. The imaging system is positioned within the surgical field and then secured to the operating room table with a maneuverable holding arm. A high-definition camera and Xenon light source allow transmission of the magnified image to a high-definition monitor in the operating room. The monitor screen is positioned above the patient for the surgeon and assistants to view real time throughout the operation. The video telescopic operating microscope system was used to provide surgical illumination and magnification during total vaginal hysterectomy and salpingectomy, midurethral sling, and release of vaginal scar procedures. All procedures were completed without complications. The video telescopic operating microscope provided illumination of the vaginal operative field and display of the magnified image onto high-definition monitors in the operating room for the surgeon and staff to simultaneously view the procedures. The video telescopic operating microscope provides high-definition display, magnification, and illumination during vaginal surgery.

  15. Empirical models for use in designing decompression procedures for space operations

    NASA Technical Reports Server (NTRS)

    Conkin, Johnny; Edwards, Benjamin F.; Waligora, James M.; Horrigan, David J., Jr.

    1987-01-01

    Empirical models for predicting the incidence of Type 1 altitude decompression sickness (DCS) and venous gas emboli (VGE) during space extravehicular activity (EVA), and for use in designing safe denitrogenation decompression procedures are developed. The models are parameterized using DCS and VGE incidence data from NASA and USAF manned altitude chamber decompression tests using 607 male and female subject tests. These models, and procedures for their use, consist of: (1) an exponential relaxation model and procedure for computing tissue nitrogen partial pressure resulting from a specified prebreathing and stepped decompression sequence; (2) a formula for calculating Tissue Ratio (TR), a tissue decompression stress index; (3) linear and Hill equation models for predicting the total incidence of VGE and DCS attendant with a particular TR; (4) graphs of cumulative DCS and VGE incidence (risk) versus EVA exposure time at any specified TR; and (5) two equations for calculating the average delay period for the initial detection of VGE or indication of Type 1 DCS in a group after a specific denitrogenation decompression procedure. Several examples of realistic EVA preparations are provided.

  16. Operational Production of the Total Ozone Essential Climate Variable as Part of the Copernicus Climate Change Service (C3S)

    NASA Astrophysics Data System (ADS)

    Lerot, C.; Danckaert, T.; van Gent, J.; Coldewey-Egbers, M.; Loyola, D. G.; Errera, Q.; Spurr, R. J. D.; Garane, K.; Koukouli, M.; Balis, D.; Verhoelst, T.; Granville, J.; Lambert, J. C.; Van Roozendael, M.

    2017-12-01

    Total ozone is one of the Essential Climate Variables (ECV) operationally produced within the European Copernicus Climate Change Service (C3S), which aims at providing the geophysical information needed to monitor and study our climate system. The C3S total ozone processing chain relies on algorithmic developments realized for the last six years as part of the ESA's Ozone Climate Change Initiative (Ozone_cci) project. The C3S Climate Data Store currently contains a total ozone record based on observations from the nadir UV-Vis hyperspectral spectrometers GOME/ERS-2, SCIAMACHY/Envisat, GOME-2/Metop-A, GOME-2/Metop-B and OMI/Aura, spanning more than 23 years.Individual level-2 datasets were generated with the retrieval algorithm GODFIT (GOME-type Direct FITting). The retrievals are based on a non-linear least squares adjustment of reflectances simulated with radiative transfer tools from the LIDORT suite, to the measured spectra in the Huggins bands (325-335 nm). The inter-sensor consistency and the time stability of those data sets is significantly enhanced with the application of a soft-calibration procedure to the level-1 reflectances, in which GOME and OMI are used together as a long-term reference. Level-2 data sets are then combined to produce the level-3 GOME-type Total Ozone (GTO-ECV) record consisting of homogenized 1°x1° monthly mean grids. The merging procedure corrects for subsisting inter-satellite biases and temporal drifts. Some developments for minimizing sampling errors have also been recently investigated and will be discussed. Total ozone level-2 and level-3 data sets are regularly verified and validated by independent measurements both from space (independent algorithms and/or instruments) and ground (Brewer/Dobson/SAOZ) and their excellent quality and stability, as well as their consistency with other long-term total ozone data sets will be illustrated here. In future, in addition to be continuously extended in time, the C3S total ozone record will also incorporate new sensors such as OMPS aboard Suomi NPP or TROPOMI/S5p.

  17. Minimum impulse trajectories for Mars round trip missions

    NASA Technical Reports Server (NTRS)

    Horvat, Glen M.; Alexander, Stephen W.

    1992-01-01

    Data are presented for minimum-impulse earth-Mars round-trip trajectories for the 2010 to 2027 Mars launch opportunities. Round-trip mission times from 120 to 600 days, including a 30-day rendezvous at Mars, for direct trajectories and trajectories utilizing a Venus gravitational assist are considered. Optimal planetary launch and arrival dates and total impulse requirements are based on all maneuvers being performed propulsively with no finite burn or other losses. Direct trajectories have the lowest impulse requirements for shorter mission times and Venus gravitational assist trajectories have the lowest impulse requirements for longer mission times. It is shown that one can depart on trajectories to Mars, beginning with lower energy trajectories to the moon. The fuel savings varies, depending on the final energy level required and on the swingby procedure used. Procedures discussed include single lunar swingbys, double-powered or unpowered lunar swingbys, third lunar flybys a year later, and gravity assists by Venus and earth after the final lunar swingby.

  18. A Study of Information Content in the U.S. Television Commercials: Has It Become Less Informative but More Creative?

    ERIC Educational Resources Information Center

    Ng, Daniel; Supaporn, Potibut

    A study investigated the trend of current U.S. television commercial informativeness by comparing the results with Alan Resnik and Bruce Stern's previous benchmark study conducted in 1977. A systematic random sampling procedure was used to select viewing dates and times of commercials from the three national networks. Ultimately, a total of 550…

  19. Mechanism and design of intermittent aeration activated sludge process for nitrogen removal.

    PubMed

    Hanhan, Oytun; Insel, Güçlü; Yagci, Nevin Ozgur; Artan, Nazik; Orhon, Derin

    2011-01-01

    The paper provided a comprehensive evaluation of the mechanism and design of intermittent aeration activated sludge process for nitrogen removal. Based on the specific character of the process the total cycle time, (T(C)), the aerated fraction, (AF), and the cycle time ratio, (CTR) were defined as major design parameters, aside from the sludge age of the system. Their impact on system performance was evaluated by means of process simulation. A rational design procedure was developed on the basis of basic stochiometry and mass balance related to the oxidation and removal of nitrogen under aerobic and anoxic conditions, which enabled selected of operation parameters of optimum performance. The simulation results indicated that the total nitrogen level could be reduced to a minimum level by appropriate manipulation of the aerated fraction and cycle time ratio. They also showed that the effluent total nitrogen could be lowered to around 4.0 mgN/L by adjusting the dissolved oxygen set-point to 0.5 mg/L, a level which promotes simultaneous nitrification and denitrification.

  20. Combination of radar and daily precipitation data to estimate meaningful sub-daily point precipitation extremes

    NASA Astrophysics Data System (ADS)

    Bárdossy, András; Pegram, Geoffrey

    2017-01-01

    The use of radar measurements for the space time estimation of precipitation has for many decades been a central topic in hydro-meteorology. In this paper we are interested specifically in daily and sub-daily extreme values of precipitation at gauged or ungauged locations which are important for design. The purpose of the paper is to develop a methodology to combine daily precipitation observations and radar measurements to estimate sub-daily extremes at point locations. Radar data corrected using precipitation-reflectivity relationships lead to biased estimations of extremes. Different possibilities of correcting systematic errors using the daily observations are investigated. Observed gauged daily amounts are interpolated to unsampled points and subsequently disaggregated using the sub-daily values obtained by the radar. Different corrections based on the spatial variability and the subdaily entropy of scaled rainfall distributions are used to provide unbiased corrections of short duration extremes. Additionally a statistical procedure not based on a matching day by day correction is tested. In this last procedure as we are only interested in rare extremes, low to medium values of rainfall depth were neglected leaving a small number of L days of ranked daily maxima in each set per year, whose sum typically comprises about 50% of each annual rainfall total. The sum of these L day maxima is first iterpolated using a Kriging procedure. Subsequently this sum is disaggregated to daily values using a nearest neighbour procedure. The daily sums are then disaggregated by using the relative values of the biggest L radar based days. Of course, the timings of radar and gauge maxima can be different, so the method presented here uses radar for disaggregating daily gauge totals down to 15 min intervals in order to extract the maxima of sub-hourly through to daily rainfall. The methodologies were tested in South Africa, where an S-band radar operated relatively continuously at Bethlehem from 1998 to 2003, whose scan at 1.5 km above ground [CAPPI] overlapped a dense (10 km spacing) set of 45 pluviometers recording in the same 6-year period. This valuable set of data was obtained from each of 37 selected radar pixels [1 km square in plan] which contained a pluviometer not masked out by the radar foot-print. The pluviometer data were also aggregated to daily totals, for the same purpose. The extremes obtained using disaggregation methods were compared to the observed extremes in a cross validation procedure. The unusual and novel goal was not to obtain the reproduction of the precipitation matching in space and time, but to obtain frequency distributions of the point extremes, which we found to be stable.

  1. 12 CFR 225.23 - Expedited action for certain nonbanking proposals by well-run bank holding companies.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... (CONTINUED) BOARD OF GOVERNORS OF THE FEDERAL RESERVE SYSTEM BANK HOLDING COMPANIES AND CHANGE IN BANK..., total capital, total assets or risk-weighted assets change as a result of the transaction, the total... procedure. The procedure in this section is available only if: (1) Well-capitalized organization—(i) Bank...

  2. The role of invasive sonography in the differential diagnosis and treatment of intraabdominal fluid collections.

    PubMed

    Regöly-Mérei, J; Ihász, M; Szeberin, Z; Záborszky, A

    Sixty-nine ultrasound-guided interventions (23 punctures and 46 drainages) were performed on 51 patients with the suspicion of intraabdominal abscess or another type of fluid collection in a prospective-controlled study. Of the procedures, 58.8% were carried out following surgery, while in 41.2% the indication were not related to prior surgical intervention. Repeated procedures were done in 10 patients. In the group of punctures the procedure was therapeutic in 3 cases and diagnostic in 16 patients. The drainage was technically successful in 92.7%. The drain was displaced or blocked in 27% (n = 10), but reinterventions were necessary in only 5 cases for this reason. The total number of redrainages was 18.9%. The percutaneous (pc) drainage was insufficient in 8 patients (21.6%), all these patients were operated on. 62.2% of the patients recovered after pc drainage, 13.5% following redrainage (total 75.5%). In 8.1% of the cases after pc drainage and in 5.4% after pc redrainage open surgery became necessary. There was only one complication due to the procedure. Seven patients (14.3%) died of the disease which indicated the procedure. There were no fatal outcomes on the account of the intervention. Ultrasound-guided puncture is a suitable method to indicate or contraindicate open surgery in the case of intraabdominal fluid collection. The diagnostic puncture may be followed by sonographically guided drainage or in selected cases by therapeutic puncture, but if the pc drainage is insufficient, open surgery should be performed in time.

  3. Prophylactic antibiotics reduce sepsis after biopsy of the prostate.

    PubMed

    Hayatzaki, Khalilullah; Menne, Sveinar; Nielsen, Karsten

    2014-11-01

    Prostate cancer is the most common form of cancer in Danish men, and the incidence is rising. The diag-nosis is made by transrectal prostate biopsy guided by ultrasound. This procedure has several complications, the most severe being sepsis. In our department, this is sought prevented by administering the prophylactic antibiotics metronidazol and ciprofloxacin. This study examined the rate of sepsis in patients who had the procedure performed at our department. The electronic patient records of all patients who had transrectal ultrasound of the prostate with biopsies performed at the Department of Urology at Naestved Hospital in the period from 1 May 2009 to 31 May 2011 were examined, and all admissions to our department (or any department in the same region) due to sepsis within two weeks of the procedure were registered. A total of 438 patients had the procedure performed, some multiple times, which resulted in a total of 511 procedures. In all, four patients were later admitted due to sepsis, corresponding to 0.91%. Three of the patients had positive blood and urine cultures in which Escherichia coli resistant to ciprofloxacin were found, the last had been prescribed antibiotics by a general practitioner the previous day, and no bacteria could be cultured. The frequency of sepsis after transrectal needle biopsies from the prostate at our department was found to be below 1% in this study, which is comparable to international findings. Most of the cases of sepsis were related to ciprofloxacin-resistant bacteria. Further randomised studies are needed to investigate the ideal prophylactic regime. not relevant. not relevant.

  4. Trans rectus sheath extra-peritoneal procedure (TREPP) for inguinal hernia: the first 1,000 patients.

    PubMed

    Lange, J F M; Lange, M M; Voropai, D A; van Tilburg, M W A; Pierie, J P E N; Ploeg, R J; Akkersdijk, W L

    2014-08-01

    After the introduction of mesh in inguinal hernia repair, the focus to improve surgical technique has changed from recurrence to chronic postoperative inguinal pain. At present, the most common surgical techniques are the Lichtenstein hernioplasty and total extraperitoneal procedure. Both techniques have their own specific disadvantages, with regard to potential nerve damage and the necessity of general anesthesia, respectively. The goal of this study was to evaluate the results of a new technique in which the inguinal nerves are not at risk, and in which general anesthesia is not needed: trans rectus sheath extraperitoneal procedure (TREPP). Between 2006 and 2010, a total of 1,000 patients were treated for inguinal hernia with TREPP. A questionnaire concerning pain, sensibility changes, patient satisfaction, and recurrence was sent to all patients. The questionnaire was completed by 932 patients. Almost 90% of patients had not experienced any pain since the surgical procedure; 8% of patients reported experiencing some pain, but less than preoperatively; and 2% of patients reported an increase in pain postoperatively. Recurrence occurred in 1 and 3% were unsure about this. Reduced sensibility of the scar, scrotum, and upper leg was reported by 12.4, 1.4, and 1.5%, respectively. Overall, 97.4% of patients were satisfied with the results of the surgical procedure. The time period in which TREPP was performed was not associated with any of the outcome measures. TREPP has proven to be a feasible new technique for inguinal hernia repair, with excellent results, justifying a randomized controlled trial in which TREPP should be compared with standard techniques.

  5. Comparison of transradial and transfemoral artery approach for percutaneous coronary angiography and angioplasty: A retrospective seven-year experience from a north Indian center

    PubMed Central

    Tewari, Satyendra; Sharma, Naveen; Kapoor, Aditya; Syal, Sanjeev Kumar; Kumar, Sudeep; Garg, Naveen; Goel, Pravin K.

    2013-01-01

    Background With the increasing prevalence of coronary artery disease, percutaneous coronary artery procedures have become even more important. Our study has compared transradial to transfemoral artery approach for coronary procedures in Indian population. Aims and objective Comparison of transradial and transfemoral artery approach for percutaneous coronary procedures. Material & methods 26,238 patients, who underwent percutaneous coronary artery procedures, were divided into two groups depending upon transradial and transfemoral artery approach and compared for the various demographic and clinical characteristics, risk factors profile, vascular access and procedural details. Results 26,238 patients underwent percutaneous coronary procedures at our center. 81% were male and 19% were female. 55.65% and 44.35% procedures were done through transfemoral and transradial approach, respectively. 17,417 (66.38%) coronary angiographies were done, out of which 53.92% were transradial and 46.08% were transfemoral procedures. 8821 (33.62%) Percutaneous Transluminal Coronary Angioplasty (PTCA) were done, out of which 25.46% and 74.54% were done through transradial and transfemoral approach, respectively. Mean fluoroscopy time was 4.40 ± 3.55 min for transradial and 3.30 ± 3.66 min for transfemoral CAG (p < 0.001). For PTCA mean fluoroscopy time was 13.53 ± 2.53 min for transradial and 12.61 ± 9.524 min for transfemoral PTCA (p < 0.001). Minor and major procedure related complications and total duration of hospital stay were lower in transradial as compared to transfemoral group. Conclusion The number of percutaneous transradial procedures have increased significantly with reduced complication rates and comparable success rate to transfemoral approach, along with the additional benefits to patient in terms of patient comfort, preference and reduced cost of health delivery. PMID:23992998

  6. The Simplified Aircraft-Based Paired Approach With the ALAS Alerting Algorithm

    NASA Technical Reports Server (NTRS)

    Perry, Raleigh B.; Madden, Michael M.; Torres-Pomales, Wilfredo; Butler, Ricky W.

    2013-01-01

    This paper presents the results of an investigation of a proposed concept for closely spaced parallel runways called the Simplified Aircraft-based Paired Approach (SAPA). This procedure depends upon a new alerting algorithm called the Adjacent Landing Alerting System (ALAS). This study used both low fidelity and high fidelity simulations to validate the SAPA procedure and test the performance of the new alerting algorithm. The low fidelity simulation enabled a determination of minimum approach distance for the worst case over millions of scenarios. The high fidelity simulation enabled an accurate determination of timings and minimum approach distance in the presence of realistic trajectories, communication latencies, and total system error for 108 test cases. The SAPA procedure and the ALAS alerting algorithm were applied to the 750-ft parallel spacing (e.g., SFO 28L/28R) approach problem. With the SAPA procedure as defined in this paper, this study concludes that a 750-ft application does not appear to be feasible, but preliminary results for 1000-ft parallel runways look promising.

  7. Image fusion-guided portal vein puncture during transjugular intrahepatic portosystemic shunt placement.

    PubMed

    Rouabah, K; Varoquaux, A; Caporossi, J M; Louis, G; Jacquier, A; Bartoli, J M; Moulin, G; Vidal, V

    2016-11-01

    The purpose of this study was to assess the feasibility and utility of image fusion (Easy-TIPS) obtained from pre-procedure CT angiography and per-procedure real-time fluoroscopy for portal vein puncture during transjugular intrahepatic portosystemic shunt (TIPS) placement. Eighteen patients (15 men, 3 women) with a mean age of 63 years (range: 48-81 years; median age, 65 years) were included in the study. All patients underwent TIPS placement by two groups of radiologists (one group with radiologists of an experience<3 years and one with an experience≥3 years) using fusion imaging obtained from three-dimensional computed tomography angiography of the portal vein and real-time fluoroscopic images of the portal vein. Image fusion was used to guide the portal vein puncture during TIPS placement. At the end of the procedure, the interventional radiologists evaluated the utility of fusion imaging for portal vein puncture during TIPS placement. Mismatch between three-dimensional computed tomography angiography and real-time fluoroscopic images of the portal vein on image fusion was quantitatively analyzed. Posttreatment CT time, number of the puncture attempts, total radiation exposure and radiation from the retrograde portography were also recorded. Image fusion was considered useful for portal vein puncture in 13/18 TIPS procedures (72%). The mean posttreatment time to obtain fusion images was 16.4minutes. 3D volume rendered CT angiography images was strictly superimposed on direct portography in 10/18 procedures (56%). The mismatch mean value was 0.69cm in height and 0.28cm laterally. A mean number of 4.6 portal vein puncture attempts was made. Eight patients required less than three attempts. The mean radiation dose from retrograde portography was 421.2dGy.cm 2 , corresponding to a mean additional exposure of 19%. Fusion imaging resulting from image fusion from pre-procedural CT angiography is feasible, safe and makes portal puncture easier during TIPS placement. Copyright © 2016 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  8. Oxygenation impairment after total arch replacement with a stented elephant trunk for type-A dissection.

    PubMed

    Shen, Yuwen; Liu, Chuanzhen; Fang, Changcun; Xi, Jie; Wu, Shuming; Pang, Xinyan; Song, Guangmin

    2018-06-01

    To study the risk factors of oxygenation impairment in patients with type-A acute aortic dissection who underwent total arch replacement with a stented elephant trunk. In this study, 169 consecutive patients were enrolled who were diagnosed with type-A acute aortic dissection and underwent a total arch replacement procedure at the Qilu Hospital of Shandong University between January 2015 and February 2017. Postoperative oxygenation impairment was defined as arterial oxygen partial pressure/inspired oxygen fraction ≤ 200 with positive end expiratory pressure ≥ 5 cm H 2 O that occurred within 72 hours of surgery. Perioperative clinical characteristics of all patients were collected and univariable analyses were performed. Risk factors associated with oxygenation impairment identified by univariable analyses were included in the multivariable regression analysis. The incidence of postoperative oxygenation impairment was 48.5%. Postoperative oxygenation impairment was associated with prolonged mechanical ventilation time, intensive care unit stay, and hospital stay. Multivariable regression analysis demonstrated that body mass index (odds ratio [OR], 1.204; 95% confidence interval [CI], 1.065-1.361; P = .003), preoperative oxygenation impairment (OR, 9.768; 95% CI, 4.159-22.941; P < .001), preoperative homocysteine (OR, 1.080; 95% CI, 1.006-1.158; P = .032), circulatory arrest time (OR, 1.123; 95% CI, 1.044-1.207; P = .002), and plasma transfusion (OR, 1.002; 95% CI, 1.001-1.003; P = .002) were significantly associated with postoperative oxygenation impairment. Postoperative oxygenation impairment is a common complication of surgery for type-A acute aortic dissection. Body mass index, preoperative oxygenation impairment, preoperative homocysteine, circulatory arrest time, and plasma transfusion were independent risk factors for oxygenation impairment after a total arch replacement procedure. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  9. Free and Cued Selective Reminding Identifies Very Mild Dementia in Primary Care

    PubMed Central

    Grober, Ellen; Sanders, Amy E.; Hall, Charles; Lipton, Richard B.

    2010-01-01

    The Free and Cued Selective Reminding Test (FCSRT) is used widely to identify very mild dementia; three alternative scoring procedures have been proposed based on free recall, total recall, and cue efficiency. We compared the predictive validity of these scoring procedures for the identification of very mild prevalent dementia (CDR=0.5), of incident dementia and for distinguishing AD and nonAD dementias. We tested 244 elderly African American and Caucasian primary care patients at 18 month intervals using a screening neuropsychological battery that included the FCSRT and a comprehensive diagnostic neuropsychological battery. Median follow-up was 2.6 years. Dementia diagnoses were assigned using standard criteria without access to the results of the screening battery. There were 50 prevalent and 28 incident dementia cases. At scores selected to provide specificities of 90%, free recall was more sensitive to incident and prevalent dementia than the other two measures. Patients with impaired free recall were 15 times more likely to have a prevalent dementia and their risk of future dementia was four times higher than patients with intact free recall. Neither race nor education affected prediction though older patients were at increased risk of future dementia. Total recall was more impaired in AD dementia than in nonAD dementias. The results indicate that using the FCSRT, free recall is best measure for detecting prevalent dementia and predicting future dementia. Total recall impairment supports the diagnosis of AD rather than nonAD dementia. PMID:20683186

  10. Conversion to Stoppa Procedure in Laparoscopic Totally Extraperitoneal Inguinal Hernia Repair

    PubMed Central

    Dirican, Abuzer; Ozgor, Dincer; Gonultas, Fatih; Isik, Burak

    2012-01-01

    Background and Objectives: Conversion to open surgery is an important problem, especially during the learning curve of laparoscopic totally extraperitoneal (TEP) inguinal hernia repair. Methods: Here, we discuss conversion to the Stoppa procedure during laparoscopic TEP inguinal hernia repair. Outcomes of patients who underwent conversion to an open approach during laparoscopic TEP inguinal hernia repair between September 2004 and May 2010 were evaluated. Results: In total, 259 consecutive patients with 281 inguinal hernias underwent laparoscopic TEP inguinal hernia repair. Thirty-one hernia repairs (11%) were converted to open conventional surgical procedures. Twenty-eight of 31 laparoscopic TEP hernia repairs were converted to modified Stoppa procedures, because of technical difficulties. Three of these patients underwent Lichtenstein hernia repairs, because they had undergone previous surgeries. Conclusion: Stoppa is an easy and successful procedure used to solve problems during TEP hernia repair. The Lichtenstein procedure may be a suitable option in patients who have undergone previous operations, such as a radical prostatectomy. PMID:23477173

  11. Determination of blood concentrations of main active compounds in Zi-Cao-Cheng-Qi decoction and their total plasma protein binding rates based on hollow fiber liquid phase microextraction coupled with high performance liquid chromatography.

    PubMed

    Li, Miaomiao; Chen, Xuan; Hu, Shuang; Wang, Runqin; Peng, Xiaoli; Bai, Xiaohong

    2018-01-01

    Oil-in-salt hollow fiber liquid phase microextraction coupled with high performance liquid chromatography ultraviolet detection (HPLC-UV) was developed for determination of the blood concentrations of the main active compounds, hesperidin, honokiol, shikonin, magnolol, emodin and β,β'-dimethylacrylshikonin, after oral administration of Zi-Cao-Cheng-Qi decoction (ZCCQD) and their total plasma protein binding rates. In the procedure, a hollow fiber segment was immersed in organic solvent to fill the solvent in the fiber lumen and wall pore, and then the fiber was immersed into sodium chloride solution to cover a thin salt membrane on the fiber wall pore filling organic solvent. Various factors affecting the procedure, such as extraction solvent, sample phase pH, stirring rate, extraction time, NaCl concentration and fiber immersion time in the NaCl solution, were optimized. Under the optimum conditions, good linearities (r 2 ≥0.9905), low limits of detection (0.7-2.5ng/mL) or quantitation (1.2-12ng/mL), satisfactory precision (2.6%-12.8%) and accuracy (81.0%-114.2%) of this method, were observed. The results showed that, after oral administration of a 25g/kg dose, (1) the blood concentrations (at 0.5h) of hesperidin, honokiol, shikonin, magnolol, emodin and β,β'-dimethylacrylshikonin were 0.45, 0.40, 0.48, 0.74, 0.11 and 1.11μg/mL, respectively; (2) the total plasma protein binding rates of the six active compounds were 42.0% (hesperidin), 71.8% (honokiol), 64.6% (shikonin), 77.7% (magnolol), 75.3% (emodin) and 75.7% (β,β'-dimethylacrylshikonin), respectively. The proposed procedure coupled with HPLC shows obvious advantages, such as low solvent consumption, simple operation, high sensitivity and strong purifying and can be used for the determination of both the blood concentrations and total plasma protein binding rates of active compounds in traditional Chinese medicine. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Comparison of conventional versus Hybrid knife peroral endoscopic myotomy methods for esophageal achalasia: a case-control study.

    PubMed

    Tang, Xiaowei; Gong, Wei; Deng, Zhiliang; Zhou, Jieqiong; Ren, Yutang; Zhang, Qiang; Chen, Zhenyu; Jiang, Bo

    2016-01-01

    Peroral endoscopic myotomy (POEM) has been developed to treat achalasia as a novel less invasive modality. We aimed to compare the efficacy and safety of conventional knife versus Hybrid knife (HK) during POEM procedure. Between June 2012 and July 2014, 31 patients underwent POEM using HK in our department (HK group), and 36 patients underwent POEM using conventional method (injection needle and triangular tip [TT] knife, TT group). Procedure-related parameters, symptom relief, adverse events were compared between two groups. There were no significant differences in the age, sex and other baseline characteristics between the two groups. The mean procedural time was significantly shorter in HK group than TT group (53.0 ± 17.2 vs. 67.6 ± 28.4 min, p = 0.015). The mean frequency of devices exchange was 4.7 ± 1.7 in HK group and 10.9 ± 1.8 in TT group (p = 0.000). No serious adverse events occurred postoperatively in both groups. At one-year follow-up, a total of 94% treatment success was achieved in all patients (93.5% in HK group and 94.4% in TT group, p = 0.877). HK in POEM can shorten the procedural time, and achieve similar treatment success compared to conventional TT knife.

  13. Medical Tourism for CCSVI Procedures in People with Multiple Sclerosis: An Observational Study.

    PubMed

    Metz, Luanne M; Greenfield, Jamie; Marrie, Ruth Ann; Jette, Nathalie; Blevins, Gregg; Svenson, Lawrence W; Alikhani, Katayoun; Wall, Winona; Dhaliwal, Raveena; Suchowersky, Oksana

    2016-05-01

    Many Canadians with multiple sclerosis (MS) have recently travelled internationally to have procedures for a putative condition called chronic cerebrospinal venous insufficiency (CCSVI). Here, we describe where and when they went and describe the baseline characteristics of persons with MS who participated in this non-evidence-based medical tourism for CCSVI procedures. We conducted a longitudinal observational study that used online questionnaires to collect patient-reported information about the safety, experiences, and outcomes following procedures for CCSVI. A convenience sample of all Albertans with MS was recruited between July 2011 and March 2013. In total, 868 individuals enrolled; 704 were included in this cross-sectional, baseline analysis. Of these, 128 (18.2%) participants retrospectively reported having procedures for CCSVI between April 2010 and September 2012. The proportion of participants reporting CCSVI procedures declined from 80 (62.5%) in 2010, to 40 (31.1%) in 2011, and 8 (6.3%) in 2012. In multivariable logistic regression analysis, CCSVI procedures were independently associated with longer disease duration, secondary progressive clinical course, and greater disability status. Although all types of people with MS pursued procedures for CCSVI, a major driver of participation was greater disability. This highlights that those with the greatest disability are the most vulnerable to unproven experimental procedures. Participation in CCSVI procedures waned over time possibly reflecting unmet expectations of treated patients, decreased media attention, or that individuals who wanted procedures had them soon after the CCSVI hypothesis was widely publicized.

  14. Temporal changes in outcomes of women and men undergoing percutaneous coronary intervention for chronic total occlusion: 2005-2013.

    PubMed

    Toma, Aurel; Stähli, Barbara E; Gick, Michael; Ferenc, Miroslaw; Mashayekhi, Kambis; Buettner, Heinz Joachim; Neumann, Franz-Josef; Gebhard, Catherine

    2018-06-01

    Percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) has undergone impressive progress during the last decade, both in strategies and equipment. It is unknown whether technical refinement has translated into improved outcomes in women undergoing CTO-PCI. A total of 2002 consecutive patients (17% females, mean age 65.2 ± 10.7 years) undergoing PCI of at least one CTO lesion at our center between 01/2005 and 12/2013 were evaluated. The incidence of adverse events was compared between two time series (2005-2009 and 2010-2013). A significant increase in adverse lesion characteristics over time was noted in both, women and men (p < 0.001), while technical success rates significantly increased in men but not in women (p trend  < 0.001 in men and p trend =0.9 in women). The incidence of procedural complications was significantly higher in women as compared to men and increased over the study period in women (p < 0.05) but not in men. Accordingly, multivariate logistic regression analysis identified female sex as a strong predictor of PCI-related complications in recent years, while this was not the case in earlier years (adjusted HR 2.03, 95% CI 0.62-6.6, p = 0.2 and adjusted HR 4.7, 95% CI 1.8-12.3, p = 0.002, respectively, p < 0.001 for log LH ratio). In addition, major adverse cardiovascular events (MACE) after a 3-year follow-up significantly declined in men (log rank = 0.046), while no changes were observed in women. While higher success rates and a reduced rate of MACE have been achieved in men, the incidence of procedural complications in women undergoing CTO-PCI has increased over time.

  15. [Current situation of enteral nutrition interruptions in sepsis children in pediatric intensive care unit].

    PubMed

    Fang, B L; Qian, S Y; Jia, X L; Li, Z; Liu, J

    2016-09-01

    To analyze the interruptions of enteral nutrition (EN) and it's relationship to prognosis in children with sepsis in pediatric intensive care unit (PICU). Daily EN intake and reasons for EN interruptions were prospectively observed and recorded in children with sepsis who were admitted to our PICU from November 2012 to April 2013. Clinical prognosis was compared between children with and without EN interruptions by t, rank-sum and χ(2) tests. Totally 60 consecutive children were included, 42 males, median age 9.67 (5.36, 37.0) months; 50 children suffered from EN interruptions, while 10 children did not. Median time to EN initiation was 2.59 (1.53, 3.67) h; EN was interrupted in 83% (50/60) of children, for a total of 108 times and 696 h, the most common reasons were fibrobronchoscopy and radiologic procedures, 27 and 29 times respectively. Children spent 0.04 (0.02, 0.08) of their total observation period without EN nutrition due to EN interruptions, and was not correlated with pediatric critically ill score (r=0.12, P=0.38). Children with EN interruptions suffered from longer PICU duration ((12±7) vs. (7±4) d, t=2.18, P=0.03), but there was no significant difference in the 28(th) hospital day's mortality between these two groups (6 cases vs. 1 case, χ(2)=0.00, P=1.00). EN is frequently interrupted due to procedures needed fasting, EN intolerance and other reasons in children with sepsis. EN interruptions may have something to do with prolonged PICU length of stay, but the relationship needs to be examined in future studies.

  16. Does Day of Surgery Affect Hospital Length of Stay and Charges Following Minimally Invasive Transforaminal Lumbar Interbody Fusion?

    PubMed

    Hijji, Fady Y; Narain, Ankur S; Haws, Brittany E; Khechen, Benjamin; Kudaravalli, Krishna T; Yom, Kelly H; Singh, Kern

    2018-06-01

    Retrospective Cohort. To determine if an association exists between surgery day and length of stay or hospital costs after minimally invasive transforaminal lumbar interbody fusion (MIS TLIF). Length of inpatient stay after orthopedic procedures has been identified as a primary cost driver, and previous research has focused on determining risk factors for prolonged length of stay. In the arthroplasty literature, surgery performed later in the week has been identified as a predictor of increased length of stay. However, no such investigation has been performed for MIS TLIF. A surgical registry of patients undergoing MIS TLIF between 2008 and 2016 was retrospectively reviewed. Patients were grouped based on day of surgery, with groups including early surgery and late surgery. Day of surgery group was tested for an association with demographics and perioperative variables using the student t test or χ analysis. Day of surgery group was then tested for an association with direct hospital costs using multivariate linear regression. In total, 438 patients were analyzed. In total, 51.8% were in the early surgery group, and 48.2% were in the late surgery group. There were no differences in demographics between groups. There were no differences between groups with regard to operative time, intraoperative blood loss, length of stay, or discharge day. Finally, there were no differences in total hospital charges between early and late surgery groups (P=0.247). The specific day on which a MIS TLIF procedure occurs is not associated with differences in length of inpatient stay or total hospital costs. This suggests that the postoperative course after MIS TLIF procedures is not affected by the differences in hospital staffing that occurs on the weekend compared with weekdays.

  17. The role of anterior hyaloid face integrity on retinal complications during Nd: YAG laser capsulotomy.

    PubMed

    Ozyol, Erhan; Ozyol, Pelin; Doğanay Erdoğan, Beyza; Onen, Mehmet

    2014-01-01

    This study evaluated anterior hyaloid damage (AHD), AHD-related Nd:YAG laser parameters, and retinal complications in subjects that underwent Nd:YAG laser posterior capsulotomy for cataracts. In this prospective, cross-sectional study, 277 pseudophakic eyes of 216 patients treated with Nd:YAG laser capsulotomy for posterior capsule opacification were enrolled. Pulse number, pulse energy, and total energy were noted for each eye. All procedures were performed with a sense of anterior hyaloid protection. Anterior hyaloid faces were assessed during procedure and 1 day after the procedure. Eyes with biomicroscopically invisible anterior hyaloid face were excluded from statistical analysis. Eyes with and without AHD were compared according to Nd:YAG laser parameters. Retinal complications were evaluated at day 1, week 1, month 1, and month 3. In 22 eyes (7.9 % of 277 eyes), the anterior hyaloid face couldn't be assessed biomicroscopically. Anterior hyaloid damage was observed in 49 eyes (19.2 % of 255 eyes). The pulse number, pulse energy, and total energy were observed to be higher in eyes with AHD (P < .001, P = .024, P < .001, respectively). Cystoid macular edema was detected in five eyes (three with AHD) at 1-week examination. Localized retinal detachment occurred in one eye with AHD. Occurrence of retinal complication in the AHD(+) group was 12.7 times higher than in the AHD(-) group, adjusted for total energy used (P < 0.001). The risk of AHD may increase with high pulse number, pulse energy, and total energy. Anterior hyaloid face integrity should be considered for YAG laser-related retinal complications.

  18. Is da Vinci Xi Better than da Vinci Si in Robotic Rectal Cancer Surgery? Comparison of the 2 Generations of da Vinci Systems.

    PubMed

    Ozben, Volkan; Cengiz, Turgut B; Atasoy, Deniz; Bayraktar, Onur; Aghayeva, Afag; Erguner, Ilknur; Baca, Bilgi; Hamzaoglu, Ismail; Karahasanoglu, Tayfun

    2016-10-01

    We aimed to compare perioperative outcomes for procedures using the latest generation of da Vinci robot versus its previous version in rectal cancer surgery. Fifty-three patients undergoing robotic rectal cancer surgery between January 2010 and March 2015 were included. Patients were classified into 2 groups (Xi, n=28 vs. Si, n=25) and perioperative outcomes were analyzed. The groups had significant differences including operative procedure, hybrid technique and redocking (P>0.05). In univariate analysis, the Xi group had shorter console times (265.7 vs. 317.1 min, P=0.006) and total operative times (321.6 vs. 360.4 min, P=0.04) and higher number of lymph nodes harvested (27.5 vs. 17.0, P=0.008). In multivariate analysis, Xi robot was associated with a shorter console time (odds ratio: 0.09, P=0.004) with no significant differences regarding other outcomes. Both generations of da Vinci robot led to similar short-term outcomes in rectal cancer surgery, but the Xi robot allowed shorter console times.

  19. The loss of essential oil components induced by the Purge Time in the Pressurized Liquid Extraction (PLE) procedure of Cupressus sempervirens.

    PubMed

    Dawidowicz, Andrzej L; Czapczyńska, Natalia B; Wianowska, Dorota

    2012-05-30

    The influence of different Purge Times on the effectiveness of Pressurized Liquid Extraction (PLE) of volatile oil components from cypress plant matrix (Cupressus sempervirens) was investigated, applying solvents of diverse extraction efficiencies. The obtained results show the decrease of the mass yields of essential oil components as a result of increased Purge Time. The loss of extracted components depends on the extrahent type - the greatest mass yield loss occurred in the case of non-polar solvents, whereas the smallest was found in polar extracts. Comparisons of the PLE method with Sea Sand Disruption Method (SSDM), Matrix Solid-Phase Dispersion Method (MSPD) and Steam Distillation (SD) were performed to assess the method's accuracy. Independent of the solvent and Purge Time applied in the PLE process, the total mass yield was lower than the one obtained for simple, short and relatively cheap low-temperature matrix disruption procedures - MSPD and SSDM. Thus, in the case of volatile oils analysis, the application of these methods is advisable. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. The best of two worlds? Pulmonary vein isolation using a novel radiofrequency ablation catheter incorporating contact force sensing technology and 56-hole porous tip irrigation.

    PubMed

    Maurer, Tilman; Rottner, Laura; Makimoto, Hisaki; Reissmann, Bruno; Heeger, Christian-H; Lemes, Christine; Fink, Thomas; Riedl, Johannes; Santoro, Francesco; Wohlmuth, Peter; Volkmer, Marius; Mathew, Shibu; Metzner, Andreas; Ouyang, Feifan; Kuck, Karl-Heinz; Sohns, Christian

    2018-05-08

    This study aimed to evaluate feasibility and safety as well as 1-year clinical outcome of pulmonary vein isolation (PVI) using a unique radiofrequency ablation catheter ("Thermocool SmartTouch SurroundFlow"; STSF) incorporating both, contact force (CF) sensing technology and enhanced tip irrigation with 56 holes, in one device. A total of 110 patients suffering from drug-refractory atrial fibrillation underwent wide area circumferential PVI using either the STSF ablation catheter (75 consecutive patients, study group) or a CF catheter with conventional tip irrigation ("Thermocool SmartTouch", 35 consecutive patients, control group). For each ablation lesion, a target CF of ≥ 10-39 g and a force time integral (FTI) of > 400 g s was targeted. Acute PVI was achieved in all patients with target CF obtained in > 85% of ablation points when using either device. Mean procedure time (131.3 ± 33.7 min in the study group vs. 133.0 ± 42.0 min in the control group; p = 0.99), mean fluoroscopy time (14.0 ± 6 vs. 13.5 ± 6.6 min; p = 0.56) and total ablation time were not significantly different (1751.0 ± 394.0 vs. 1604.6 ± 287.8 s; p = 0.2). However, there was a marked reduction in total irrigation fluid delivery by 51.7% (265.52 ± 64.4 vs. 539.6 ± 118.2 ml; p < 0.01). The Kaplan-Meier estimate 12-month arrhythmia-free survival after the index procedure following a 3-month blanking period was 79.9% (95% CI 70.4%, 90.4%) for the study group and 66.7% for the control group (95% CI 50.2%, 88.5%). This finding did not reach statistical significance (p = 0.18). Major complications occurred in 2/75 patients (2.7%; one pericardial tamponade and one transient ischemic attack) in the study group and no patient in the control group (p = 18). PVI using the STSF catheter is safe and effective and results in beneficial 1-year clinical outcome. The improved tip irrigation leads to a significant reduction in procedural fluid burden.

Top