Sample records for total system reliability

  1. Reliability and Cost Impacts for Attritable Systems

    DTIC Science & Technology

    2017-03-23

    and cost risk metrics to convey the value of reliability and reparability trades. Investigation of the benefit of trading system reparability...illustrates the benefit that reliability engineering can have on total cost . 2.3.1 Contexts of System Reliability Hogge (2012) identifies two distinct...reliability and reparability trades. Investigation of the benefit of trading system reparability shows a marked increase in cost risk. Yet, trades in

  2. Design and Analysis of a Flexible, Reliable Deep Space Life Support System

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.

    2012-01-01

    This report describes a flexible, reliable, deep space life support system design approach that uses either storage or recycling or both together. The design goal is to provide the needed life support performance with the required ultra reliability for the minimum Equivalent System Mass (ESM). Recycling life support systems used with multiple redundancy can have sufficient reliability for deep space missions but they usually do not save mass compared to mixed storage and recycling systems. The best deep space life support system design uses water recycling with sufficient water storage to prevent loss of crew if recycling fails. Since the amount of water needed for crew survival is a small part of the total water requirement, the required amount of stored water is significantly less than the total to be consumed. Water recycling with water, oxygen, and carbon dioxide removal material storage can achieve the high reliability of full storage systems with only half the mass of full storage and with less mass than the highly redundant recycling systems needed to achieve acceptable reliability. Improved recycling systems with lower mass and higher reliability could perform better than systems using storage.

  3. Key Reliability Drivers of Liquid Propulsion Engines and A Reliability Model for Sensitivity Analysis

    NASA Technical Reports Server (NTRS)

    Huang, Zhao-Feng; Fint, Jeffry A.; Kuck, Frederick M.

    2005-01-01

    This paper is to address the in-flight reliability of a liquid propulsion engine system for a launch vehicle. We first establish a comprehensive list of system and sub-system reliability drivers for any liquid propulsion engine system. We then build a reliability model to parametrically analyze the impact of some reliability parameters. We present sensitivity analysis results for a selected subset of the key reliability drivers using the model. Reliability drivers identified include: number of engines for the liquid propulsion stage, single engine total reliability, engine operation duration, engine thrust size, reusability, engine de-rating or up-rating, engine-out design (including engine-out switching reliability, catastrophic fraction, preventable failure fraction, unnecessary shutdown fraction), propellant specific hazards, engine start and cutoff transient hazards, engine combustion cycles, vehicle and engine interface and interaction hazards, engine health management system, engine modification, engine ground start hold down with launch commit criteria, engine altitude start (1 in. start), Multiple altitude restart (less than 1 restart), component, subsystem and system design, manufacturing/ground operation support/pre and post flight check outs and inspection, extensiveness of the development program. We present some sensitivity analysis results for the following subset of the drivers: number of engines for the propulsion stage, single engine total reliability, engine operation duration, engine de-rating or up-rating requirements, engine-out design, catastrophic fraction, preventable failure fraction, unnecessary shutdown fraction, and engine health management system implementation (basic redlines and more advanced health management systems).

  4. System engineering of complex optical systems for mission assurance and affordability

    NASA Astrophysics Data System (ADS)

    Ahmad, Anees

    2017-08-01

    Affordability and reliability are equally important as the performance and development time for many optical systems for military, space and commercial applications. These characteristics are even more important for the systems meant for space and military applications where total lifecycle costs must be affordable. Most customers are looking for high performance optical systems that are not only affordable but are designed with "no doubt" mission assurance, reliability and maintainability in mind. Both US military and commercial customers are now demanding an optimum balance between performance, reliability and affordability. Therefore, it is important to employ a disciplined systems design approach for meeting the performance, cost and schedule targets while keeping affordability and reliability in mind. The US Missile Defense Agency (MDA) now requires all of their systems to be engineered, tested and produced according to the Mission Assurance Provisions (MAP). These provisions or requirements are meant to ensure complex and expensive military systems are designed, integrated, tested and produced with the reliability and total lifecycle costs in mind. This paper describes a system design approach based on the MAP document for developing sophisticated optical systems that are not only cost-effective but also deliver superior and reliable performance during their intended missions.

  5. Total systems design analysis of high performance structures

    NASA Technical Reports Server (NTRS)

    Verderaime, V.

    1993-01-01

    Designer-control parameters were identified at interdiscipline interfaces to optimize structural systems performance and downstream development and operations with reliability and least life-cycle cost. Interface tasks and iterations are tracked through a matrix of performance disciplines integration versus manufacturing, verification, and operations interactions for a total system design analysis. Performance integration tasks include shapes, sizes, environments, and materials. Integrity integrating tasks are reliability and recurring structural costs. Significant interface designer control parameters were noted as shapes, dimensions, probability range factors, and cost. Structural failure concept is presented, and first-order reliability and deterministic methods, benefits, and limitations are discussed. A deterministic reliability technique combining benefits of both is proposed for static structures which is also timely and economically verifiable. Though launch vehicle environments were primarily considered, the system design process is applicable to any surface system using its own unique filed environments.

  6. Reliability studies of Integrated Modular Engine system designs

    NASA Technical Reports Server (NTRS)

    Hardy, Terry L.; Rapp, Douglas C.

    1993-01-01

    A study was performed to evaluate the reliability of Integrated Modular Engine (IME) concepts. Comparisons were made between networked IME systems and non-networked discrete systems using expander cycle configurations. Both redundant and non-redundant systems were analyzed. Binomial approximation and Markov analysis techniques were employed to evaluate total system reliability. In addition, Failure Modes and Effects Analyses (FMEA), Preliminary Hazard Analyses (PHA), and Fault Tree Analysis (FTA) were performed to allow detailed evaluation of the IME concept. A discussion of these system reliability concepts is also presented.

  7. Reliability studies of integrated modular engine system designs

    NASA Technical Reports Server (NTRS)

    Hardy, Terry L.; Rapp, Douglas C.

    1993-01-01

    A study was performed to evaluate the reliability of Integrated Modular Engine (IME) concepts. Comparisons were made between networked IME systems and non-networked discrete systems using expander cycle configurations. Both redundant and non-redundant systems were analyzed. Binomial approximation and Markov analysis techniques were employed to evaluate total system reliability. In addition, Failure Modes and Effects Analyses (FMEA), Preliminary Hazard Analyses (PHA), and Fault Tree Analysis (FTA) were performed to allow detailed evaluation of the IME concept. A discussion of these system reliability concepts is also presented.

  8. Reliability studies of integrated modular engine system designs

    NASA Astrophysics Data System (ADS)

    Hardy, Terry L.; Rapp, Douglas C.

    1993-06-01

    A study was performed to evaluate the reliability of Integrated Modular Engine (IME) concepts. Comparisons were made between networked IME systems and non-networked discrete systems using expander cycle configurations. Both redundant and non-redundant systems were analyzed. Binomial approximation and Markov analysis techniques were employed to evaluate total system reliability. In addition, Failure Modes and Effects Analyses (FMEA), Preliminary Hazard Analyses (PHA), and Fault Tree Analysis (FTA) were performed to allow detailed evaluation of the IME concept. A discussion of these system reliability concepts is also presented.

  9. Reliability studies of Integrated Modular Engine system designs

    NASA Astrophysics Data System (ADS)

    Hardy, Terry L.; Rapp, Douglas C.

    1993-06-01

    A study was performed to evaluate the reliability of Integrated Modular Engine (IME) concepts. Comparisons were made between networked IME systems and non-networked discrete systems using expander cycle configurations. Both redundant and non-redundant systems were analyzed. Binomial approximation and Markov analysis techniques were employed to evaluate total system reliability. In addition, Failure Modes and Effects Analyses (FMEA), Preliminary Hazard Analyses (PHA), and Fault Tree Analysis (FTA) were performed to allow detailed evaluation of the IME concept. A discussion of these system reliability concepts is also presented.

  10. Reliability of the Balance Evaluation Systems Test (BESTest) and BESTest sections for adults with hemiparesis

    PubMed Central

    Rodrigues, Letícia C.; Marques, Aline P.; Barros, Paula B.; Michaelsen, Stella M.

    2014-01-01

    BACKGROUND: The Balance Evaluation Systems Test (BESTest) was recently created to allow the development of treatments according to the specific balance system affected in each patient. The Brazilian version of the BESTest has not been specifically tested after stroke. OBJECTIVE: To evaluate the intra- and inter-rater reliability and concurrent and convergent validity of the total score of the BESTest and BESTest sections for adults with hemiparesis after stroke. METHOD: The study included 16 subjects (61.1±7.5 years) with chronic hemiparesis (54.5±43.5 months after stroke). The BESTest was administered by two raters in the same week and one of the raters repeated the test after a one-week interval. Intraclass correlation coefficient (ICC) was calculated to assess intra- and interrater reliability. Concurrent validity with the Berg Balance Scale (BBS) and convergent validity with the Activities-specific Balance Confidence scale (ABC-Brazil) were assessed using Pearson's correlation coefficient. RESULTS: Both the BESTest total score (ICC=0.98) and the BESTest sections (ICC between 0.85 and 0.96) have excellent intrarater reliability. Interrater reliability for the total score was excellent (ICC=0.93) and, for the sections, it ranged between 0.71 and 0.94. The correlation coefficient between the BESTest and the BBS and ABC-Brazil were 0.78 and 0.59, respectively. CONCLUSIONS: The Brazilian version of the BESTest demonstrated adequate reliability when measured by sections and could identify what balance system was affected in patients after stroke. Concurrent validity was excellent with the BBS total score and good to excellent with the sections. The total scores but not the sections present adequate convergent validity with the ABC-Brazil. However, other psychometric properties should be further investigated. PMID:25003281

  11. User's guide to the Reliability Estimation System Testbed (REST)

    NASA Technical Reports Server (NTRS)

    Nicol, David M.; Palumbo, Daniel L.; Rifkin, Adam

    1992-01-01

    The Reliability Estimation System Testbed is an X-window based reliability modeling tool that was created to explore the use of the Reliability Modeling Language (RML). RML was defined to support several reliability analysis techniques including modularization, graphical representation, Failure Mode Effects Simulation (FMES), and parallel processing. These techniques are most useful in modeling large systems. Using modularization, an analyst can create reliability models for individual system components. The modules can be tested separately and then combined to compute the total system reliability. Because a one-to-one relationship can be established between system components and the reliability modules, a graphical user interface may be used to describe the system model. RML was designed to permit message passing between modules. This feature enables reliability modeling based on a run time simulation of the system wide effects of a component's failure modes. The use of failure modes effects simulation enhances the analyst's ability to correctly express system behavior when using the modularization approach to reliability modeling. To alleviate the computation bottleneck often found in large reliability models, REST was designed to take advantage of parallel processing on hypercube processors.

  12. Towards cost-effective reliability through visualization of the reliability option space

    NASA Technical Reports Server (NTRS)

    Feather, Martin S.

    2004-01-01

    In planning a complex system's development there can be many options to improve its reliability. Typically their sum total cost exceeds the budget available, so it is necessary to select judiciously from among them. Reliability models can be employed to calculate the cost and reliability implications of a candidate selection.

  13. Reliability and Geographic Trends of 50,000 Photovoltaic Systems in the USA: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jordan, D. C.; Kurtz, S. R.

    2014-09-01

    This paper presents performance and reliability data from nearly 50,000 photovoltaic (PV) systems totaling 1.7 gigawatts installed capacity in the USA from 2009 to 2012 and their geographic trends. About 90% of the normal systems and about 85% of all systems, including systems with known issues, performed to within 10% or better of expected performance. Although considerable uncertainty may exist due to the nature of the data, hotter climates appear to exhibit some degradation not seen in the more moderate climates. Special causes of underperformance and their impacts are delineated by reliability category. Hardware-related issues are dominated by inverter problemsmore » (totaling less than 0.5%) and underperforming modules (totaling less than 0.1%). Furthermore, many reliability categories show a significant decrease in occurrence from year 1 to subsequent years, emphasizing the need for higher-quality installations but also the need for improved standards development. The probability of PV system damage because of hail is below 0.05%. Singular weather events can have a significant impact such as a single lightning strike to a transformer or the impact of a hurricane. However, grid outages are more likely to have a significant impact than PV system damage when extreme weather events occur.« less

  14. Reliability/safety analysis of a fly-by-wire system

    NASA Technical Reports Server (NTRS)

    Brock, L. D.; Goddman, H. A.

    1980-01-01

    An analysis technique has been developed to estimate the reliability of a very complex, safety-critical system by constructing a diagram of the reliability equations for the total system. This diagram has many of the characteristics of a fault-tree or success-path diagram, but is much easier to construct for complex redundant systems. The diagram provides insight into system failure characteristics and identifies the most likely failure modes. A computer program aids in the construction of the diagram and the computation of reliability. Analysis of the NASA F-8 Digital Fly-by-Wire Flight Control System is used to illustrate the technique.

  15. The B-747 flight control system maintenance and reliability data base for cost effectiveness tradeoff studies

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Primary and automatic flight controls are combined for a total flight control reliability and maintenance cost data base using information from two previous reports and additional cost data gathered from a major airline. A comparison of the current B-747 flight control system effects on reliability and operating cost with that of a B-747 designed for an active control wing load alleviation system is provided.

  16. Reliability of an ordinal rating system for assessing the amount of mud and feces (tag) on cattle hides at slaughter.

    PubMed

    Jordan, D; McEwen, S A; Wilson, J B; McNab, W B; Lammerding, A M

    1999-05-01

    A study was conducted to provide a quantitative description of the amount of tag (mud, soil, and bedding) adhered to the hides of feedlot beef cattle and to appraise the statistical reliability of a subjective rating system for assessing this trait. Initially, a single rater obtained baseline data by assessing 2,417 cattle for 1 month at an Ontario beef processing plant. Analysis revealed that there was a strong tendency for animals within sale-lots to have a similar total tag score (intralot correlation = 0.42). Baseline data were summarized by fitting a linear model describing an individual's total tag score as the sum of their lot mean tag score (LMTS) plus an amount representing normal variation within the lot. LMTSs predicted by the linear model were adequately described by a beta distribution with parameters nu = 3.12 and omega = 5.82 scaled to fit on the 0-to-9 interval. Five raters, trained in use of the tag scoring system, made 1,334 tag score observations in a commercial abattoir, allowing reliability to be assessed at the individual level and at the lot level. High values for reliability were obtained for individual total tag score (0.84) and lot total tag score (0.83); these values suggest that the tag scoring system could be used in the marketing and slaughter of Ontario beef cattle to improve the cleanliness of animals presented for slaughter in an effort to control the entry of microbial contamination into abattoirs. Implications for the use of the tag scoring system in research are discussed.

  17. Interobserver Reliability of the Total Body Score System for Quantifying Human Decomposition.

    PubMed

    Dabbs, Gretchen R; Connor, Melissa; Bytheway, Joan A

    2016-03-01

    Several authors have tested the accuracy of the Total Body Score (TBS) method for quantifying decomposition, but none have examined the reliability of the method as a scoring system by testing interobserver error rates. Sixteen participants used the TBS system to score 59 observation packets including photographs and written descriptions of 13 human cadavers in different stages of decomposition (postmortem interval: 2-186 days). Data analysis used a two-way random model intraclass correlation in SPSS (v. 17.0). The TBS method showed "almost perfect" agreement between observers, with average absolute correlation coefficients of 0.990 and average consistency correlation coefficients of 0.991. While the TBS method may have sources of error, scoring reliability is not one of them. Individual component scores were examined, and the influences of education and experience levels were investigated. Overall, the trunk component scores were the least concordant. Suggestions are made to improve the reliability of the TBS method. © 2016 American Academy of Forensic Sciences.

  18. Reliability of digital ulcer definitions as proposed by the UK Scleroderma Study Group: A challenge for clinical trial design.

    PubMed

    Hughes, Michael; Tracey, Andrew; Bhushan, Monica; Chakravarty, Kuntal; Denton, Christopher P; Dubey, Shirish; Guiducci, Serena; Muir, Lindsay; Ong, Voon; Parker, Louise; Pauling, John D; Prabu, Athiveeraramapandian; Rogers, Christine; Roberts, Christopher; Herrick, Ariane L

    2018-06-01

    The reliability of clinician grading of systemic sclerosis-related digital ulcers has been reported to be poor to moderate at best, which has important implications for clinical trial design. The aim of this study was to examine the reliability of new proposed UK Scleroderma Study Group digital ulcer definitions among UK clinicians with an interest in systemic sclerosis. Raters graded (through a custom-built interface) 90 images (80 unique and 10 repeat) of a range of digital lesions collected from patients with systemic sclerosis. Lesions were graded on an ordinal scale of severity: 'no ulcer', 'healed ulcer' or 'digital ulcer'. A total of 23 clinicians - 18 rheumatologists, 3 dermatologists, 1 hand surgeon and 1 specialist rheumatology nurse - completed the study. A total of 2070 (1840 unique + 230 repeat) image gradings were obtained. For intra-rater reliability, across all images, the overall weighted kappa coefficient was high (0.71) and was moderate (0.55) when averaged across individual raters. Overall inter-rater reliability was poor (0.15). Although our proposed digital ulcer definitions had high intra-rater reliability, the overall inter-rater reliability was poor. Our study highlights the challenges of digital ulcer assessment by clinicians with an interest in systemic sclerosis and provides a number of useful insights for future clinical trial design. Further research is warranted to improve the reliability of digital ulcer definition/rating as an outcome measure in clinical trials, including examining the role for objective measurement techniques, and the development of digital ulcer patient-reported outcome measures.

  19. HiRel - Reliability/availability integrated workstation tool

    NASA Technical Reports Server (NTRS)

    Bavuso, Salvatore J.; Dugan, Joanne B.

    1992-01-01

    The HiRel software tool is described and demonstrated by application to the mission avionics subsystem of the Advanced System Integration Demonstrations (ASID) system that utilizes the PAVE PILLAR approach. HiRel marks another accomplishment toward the goal of producing a totally integrated computer-aided design (CAD) workstation design capability. Since a reliability engineer generally represents a reliability model graphically before it can be solved, the use of a graphical input description language increases productivity and decreases the incidence of error. The graphical postprocessor module HARPO makes it possible for reliability engineers to quickly analyze huge amounts of reliability/availability data to observe trends due to exploratory design changes. The addition of several powerful HARP modeling engines provides the user with a reliability/availability modeling capability for a wide range of system applications all integrated under a common interactive graphical input-output capability.

  20. Reliability and validity of the Microsoft Kinect for evaluating static foot posture

    PubMed Central

    2013-01-01

    Background The evaluation of foot posture in a clinical setting is useful to screen for potential injury, however disagreement remains as to which method has the greatest clinical utility. An inexpensive and widely available imaging system, the Microsoft Kinect™, may possess the characteristics to objectively evaluate static foot posture in a clinical setting with high accuracy. The aim of this study was to assess the intra-rater reliability and validity of this system for assessing static foot posture. Methods Three measures were used to assess static foot posture; traditional visual observation using the Foot Posture Index (FPI), a 3D motion analysis (3DMA) system and software designed to collect and analyse image and depth data from the Kinect. Spearman’s rho was used to assess intra-rater reliability and concurrent validity of the Kinect to evaluate foot posture, and a linear regression was used to examine the ability of the Kinect to predict total visual FPI score. Results The Kinect demonstrated moderate to good intra-rater reliability for four FPI items of foot posture (ρ = 0.62 to 0.78) and moderate to good correlations with the 3DMA system for four items of foot posture (ρ = 0.51 to 0.85). In contrast, intra-rater reliability of visual FPI items was poor to moderate (ρ = 0.17 to 0.63), and correlations with the Kinect and 3DMA systems were poor (absolute ρ = 0.01 to 0.44). Kinect FPI items with moderate to good reliability predicted 61% of the variance in total visual FPI score. Conclusions The majority of the foot posture items derived using the Kinect were more reliable than the traditional visual assessment of FPI, and were valid when compared to a 3DMA system. Individual foot posture items recorded using the Kinect were also shown to predict a moderate degree of variance in the total visual FPI score. Combined, these results support the future potential of the Kinect to accurately evaluate static foot posture in a clinical setting. PMID:23566934

  1. Development of a low risk augmentation system for an energy efficient transport having relaxed static stability

    NASA Technical Reports Server (NTRS)

    Sizlo, T. R.; Berg, R. A.; Gilles, D. L.

    1979-01-01

    An augmentation system for a 230 passenger, twin engine aircraft designed with a relaxation of conventional longitudinal static stability was developed. The design criteria are established and candidate augmentation system control laws and hardware architectures are formulated and evaluated with respect to reliability, flying qualities, and flight path tracking performance. The selected systems are shown to satisfy the interpreted regulatory safety and reliability requirements while maintaining the present DC 10 (study baseline) level of maintainability and reliability for the total flight control system. The impact of certification of the relaxed static stability augmentation concept is also estimated with regard to affected federal regulations, system validation plan, and typical development/installation costs.

  2. Reliability Evaluation of Machine Center Components Based on Cascading Failure Analysis

    NASA Astrophysics Data System (ADS)

    Zhang, Ying-Zhi; Liu, Jin-Tong; Shen, Gui-Xiang; Long, Zhe; Sun, Shu-Guang

    2017-07-01

    In order to rectify the problems that the component reliability model exhibits deviation, and the evaluation result is low due to the overlook of failure propagation in traditional reliability evaluation of machine center components, a new reliability evaluation method based on cascading failure analysis and the failure influenced degree assessment is proposed. A direct graph model of cascading failure among components is established according to cascading failure mechanism analysis and graph theory. The failure influenced degrees of the system components are assessed by the adjacency matrix and its transposition, combined with the Pagerank algorithm. Based on the comprehensive failure probability function and total probability formula, the inherent failure probability function is determined to realize the reliability evaluation of the system components. Finally, the method is applied to a machine center, it shows the following: 1) The reliability evaluation values of the proposed method are at least 2.5% higher than those of the traditional method; 2) The difference between the comprehensive and inherent reliability of the system component presents a positive correlation with the failure influenced degree of the system component, which provides a theoretical basis for reliability allocation of machine center system.

  3. Statistical Aspects of Reliability, Maintainability, and Availability.

    DTIC Science & Technology

    1987-10-01

    A total of 33 research reports were issued, and 35 papers were published in scientific journals or are in press. Research topics included optimal assembly of systems, multistate system theory , testing whether new is better than used nonparameter survival function estimation measuring information in censored models, generalizations of total positively and

  4. TOTAL user manual

    NASA Technical Reports Server (NTRS)

    Johnson, Sally C.; Boerschlein, David P.

    1994-01-01

    Semi-Markov models can be used to analyze the reliability of virtually any fault-tolerant system. However, the process of delineating all of the states and transitions in the model of a complex system can be devastatingly tedious and error-prone. Even with tools such as the Abstract Semi-Markov Specification Interface to the SURE Tool (ASSIST), the user must describe a system by specifying the rules governing the behavior of the system in order to generate the model. With the Table Oriented Translator to the ASSIST Language (TOTAL), the user can specify the components of a typical system and their attributes in the form of a table. The conditions that lead to system failure are also listed in a tabular form. The user can also abstractly specify dependencies with causes and effects. The level of information required is appropriate for system designers with little or no background in the details of reliability calculations. A menu-driven interface guides the user through the system description process, and the program updates the tables as new information is entered. The TOTAL program automatically generates an ASSIST input description to match the system description.

  5. Interrater and Test-Retest Reliability and Minimal Detectable Change of the Balance Evaluation Systems Test (BESTest) and Subsystems With Community-Dwelling Older Adults.

    PubMed

    Wang-Hsu, Elizabeth; Smith, Susan S

    2017-01-10

    Falls are a common cause of injuries and hospital admissions in older adults. Balance limitation is a potentially modifiable factor contributing to falls. The Balance Evaluation Systems Test (BESTest), a clinical balance measure, categorizes balance into 6 underlying subsystems. Each of the subsystems is scored individually and summed to obtain a total score. The reliability of the BESTest and its individual subsystems has been reported in patients with various neurological disorders and cancer survivors. However, the reliability and minimal detectable change (MDC) of the BESTest with community-dwelling older adults have not been reported. The purposes of our study were to (1) determine the interrater and test-retest reliability of the BESTest total and subsystem scores; and (2) estimate the MDC of the BESTest and its individual subsystem scores with community-dwelling older adults. We used a prospective cohort methodological design. Community-dwelling older adults (N = 70; aged 70-94 years; mean = 85.0 [5.5] years) were recruited from a senior independent living community. Trained testers (N = 3) administered the BESTest. All participants were tested with the BESTest by the same tester initially and then retested 7 to 14 days later. With 32 of the participants, a second tester concurrently scored the retest for interrater reliability. Testers were blinded to each other's scores. Intraclass correlation coefficients [ICC(2,1)] were used to determine the interrater and test-retest reliability. Test-retest reliability was also analyzed using method error and the associated coefficients of variation (CVME). MDC was calculated using standard error of measurement. Interrater reliability (N = 32) of the BESTest total score was ICC(2, 1) = 0.97 (95% confidence interval [CI], 0.94-0.99). The ICCs for the individual subsystem scores ranged from 0.85 to 0.94. Test-retest reliability (N = 70) of the BESTest total score was ICC(2,1) = 0.93 (95% CI, 0.89-0.96). ICCs for the individual subsystem scores ranged from 0.72 to 0.89. The CVME (N = 70) of the BESTest total score was 4.1%. The CVME for the subsystem scores ranged from 5.0% to 10.7%. MDC (N = 70) for the BESTest total score at the 95% CI was 7.6%, or 8.2 points. MDC at the 95% CI for subsystem scores ranged from 11.7% to 19.0% (2.1-3.4 points). Results demonstrated generally good to excellent interrater and test-retest reliability in both the BESTest total and subsystem scores with community-dwelling older adults. The BESTest total and individual subsystem scores demonstrate good to excellent interrater and test-retest reliability with community-dwelling older adults. A change of 7.6% (8.2 points) or more in the BESTest total and a percentage change ranged from 11.7% to 19.0% (2.1-3.4 points) in the subsystem scores are suggested for clinicians to be 95% confident of true change when evaluating change in this population.

  6. The welfare effects of integrating renewable energy into electricity markets

    NASA Astrophysics Data System (ADS)

    Lamadrid, Alberto J.

    The challenges of deploying more renewable energy sources on an electric grid are caused largely by their inherent variability. In this context, energy storage can help make the electric delivery system more reliable by mitigating this variability. This thesis analyzes a series of models for procuring electricity and ancillary services for both individuals and social planners with high penetrations of stochastic wind energy. The results obtained for an individual decision maker using stochastic optimization are ambiguous, with closed form solutions dependent on technological parameters, and no consideration of the system reliability. The social planner models correctly reflect the effect of system reliability, and in the case of a Stochastic, Security Constrained Optimal Power Flow (S-SC-OPF or SuperOPF), determine reserve capacity endogenously so that system reliability is maintained. A single-period SuperOPF shows that including ramping costs in the objective function leads to more wind spilling and increased capacity requirements for reliability. However, this model does not reflect the inter temporal tradeoffs of using Energy Storage Systems (ESS) to improve reliability and mitigate wind variability. The results with the multiperiod SuperOPF determine the optimum use of storage for a typical day, and compare the effects of collocating ESS at wind sites with the same amount of storage (deferrable demand) located at demand centers. The collocated ESS has slightly lower operating costs and spills less wind generation compared to deferrable demand, but the total amount of conventional generating capacity needed for system adequacy is higher. In terms of the total system costs, that include the capital cost of conventional generating capacity, the costs with deferrable demand is substantially lower because the daily demand profile is flattened and less conventional generation capacity is then needed for reliability purposes. The analysis also demonstrates that the optimum daily pattern of dispatch and reserves is seriously distorted if the stochastic characteristics of wind generation are ignored.

  7. Renewal of the Control System and Reliable Long Term Operation of the LHD Cryogenic System

    NASA Astrophysics Data System (ADS)

    Mito, T.; Iwamoto, A.; Oba, K.; Takami, S.; Moriuchi, S.; Imagawa, S.; Takahata, K.; Yamada, S.; Yanagi, N.; Hamaguchi, S.; Kishida, F.; Nakashima, T.

    The Large Helical Device (LHD) is a heliotron-type fusion plasma experimental machine which consists of a fully superconducting magnet system cooled by a helium refrigerator having a total equivalent cooling capacity of 9.2 kW@4.4 K. Seventeenplasma experimental campaigns have been performed successfully since1997 with high reliability of 99%. However, sixteen years have passed from the beginning of the system operation. Improvements are being implementedto prevent serious failures and to pursue further reliability.The LHD cryogenic control system was designed and developed as an open system utilizing latest control equipment of VME controllers and UNIX workstations at the construction time. Howeverthe generation change of control equipment has been advanced. Down-sizing of control deviceshas beenplanned from VME controllers to compact PCI controllers in order to simplify the system configuration and to improve the system reliability. The new system is composed of compact PCI controller and remote I/O connected with EtherNet/IP. Making the system redundant becomes possible by doubling CPU, LAN, and remote I/O respectively. The smooth renewal of the LHD cryogenic controlsystem and the further improvement of the cryogenic system reliability are reported.

  8. Solar-Powered Supply Is Light and Reliable

    NASA Technical Reports Server (NTRS)

    Willis, A. E.; Garrett, H.; Matheney, J.

    1982-01-01

    DC supply originally intended for use in solar-powered spacecraft propulsion is lightweight and very reliable. Operates from 100-200 volt output of solar panels to produce 11 different dc voltages, with total demand of 3,138 watts. With exception of specially wound inductors and transformers, system uses readily available components.

  9. A Quantitative Assessment of Utility Reporting Practices for Reporting Electric Power Distribution Events

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hamachi La Commare, Kristina

    Metrics for reliability, such as the frequency and duration of power interruptions, have been reported by electric utilities for many years. This study examines current utility practices for collecting and reporting electricity reliability information and discusses challenges that arise in assessing reliability because of differences among these practices. The study is based on reliability information for year 2006 reported by 123 utilities in 37 states representing over 60percent of total U.S. electricity sales. We quantify the effects that inconsistencies among current utility reporting practices have on comparisons of System Average Interruption Duration Index (SAIDI) and System Average Interruption Frequency Indexmore » (SAIFI) reported by utilities. We recommend immediate adoption of IEEE Std. 1366-2003 as a consistent method for measuring and reporting reliability statistics.« less

  10. Reliability of the Cooking Task in adults with acquired brain injury.

    PubMed

    Poncet, Frédérique; Swaine, Bonnie; Taillefer, Chantal; Lamoureux, Julie; Pradat-Diehl, Pascale; Chevignard, Mathilde

    2015-01-01

    Acquired brain injury (ABI) often leads to deficits in executive functioning (EF) responsible for severe and long-standing disabilities in daily life activities. The Cooking Task is an ecological and valid test of EF involving multi-tasking in a real environment. Given its complex scoring system, it is important to establish the tool's reliability. The objective of the study was to examine the reliability of the Cooking Task (internal consistency, inter-rater and test-retest reliability). A total of 160 patients with ABI (113 men, mean age 37 years, SD = 14.3) were tested using the Cooking Task. For test-retest reliability, patients were assessed by the same rater on two occasions (mean interval 11 days) while two raters independently and simultaneously observed and scored patients' performances to estimate inter-rater reliability. Internal consistency was high for the global scale (Cronbach α = .74). Inter-rater reliability (n = 66) for total errors was also high (ICC = .93), however the test-retest reliability (n = 11) was poor (ICC = .36). In general the Cooking Task appears to be a reliable tool. The low test-retest results were expected given the importance of EF in the performance of novel tasks.

  11. The postoperative COFAS end-stage ankle arthritis classification system: interobserver and intraobserver reliability.

    PubMed

    Krause, Fabian G; Di Silvestro, Matthew; Penner, Murray J; Wing, Kevin J; Glazebrook, Mark A; Daniels, Timothy R; Lau, Johnny T C; Younger, Alastair S E

    2012-02-01

    End-stage ankle arthritis is operatively treated with numerous designs of total ankle replacement and different techniques for ankle fusion. For superior comparison of these procedures, outcome research requires a classification system to stratify patients appropriately. A postoperative 4-type classification system was designed by 6 fellowship-trained foot and ankle surgeons. Four surgeons reviewed blinded patient profiles and radiographs on 2 occasions to determine the interobserver and intraobserver reliability of the classification. Excellent interobserver reliability (κ = .89) and intraobserver reproducibility (κ = .87) were demonstrated for the postoperative classification system. In conclusion, the postoperative Canadian Orthopaedic Foot and Ankle Society (COFAS) end-stage ankle arthritis classification system appears to be a valid tool to evaluate the outcome of patients operated for end-stage ankle arthritis.

  12. Evaluation of air-displacement plethysmography for body composition assessment in preterm infants

    USDA-ARS?s Scientific Manuscript database

    Adiposity may contribute to the future risk of disease. The aim of this study was to evaluate the accuracy and reliability of an air-displacement plethysmography (ADP) system to estimate percentage fat mass (%FM) in preterm infants and to evaluate interdevice reliability in infants. A total of 70 pr...

  13. Reliability and cost: A sensitivity analysis

    NASA Technical Reports Server (NTRS)

    Suich, Ronald C.; Patterson, Richard L.

    1991-01-01

    In the design phase of a system, how a design engineer or manager choose between a subsystem with .990 reliability and a more costly subsystem with .995 reliability is examined, along with the justification of the increased cost. High reliability is not necessarily an end in itself but may be desirable in order to reduce the expected cost due to subsystem failure. However, this may not be the wisest use of funds since the expected cost due to subsystem failure is not the only cost involved. The subsystem itself may be very costly. The cost of the subsystem nor the expected cost due to subsystem failure should not be considered separately but the total of the two costs should be maximized, i.e., the total of the cost of the subsystem plus the expected cost due to subsystem failure.

  14. MEASURING SPORT-SPECIFIC PHYSICAL ABILITIES IN MALE GYMNASTS: THE MEN'S GYMNASTICS FUNCTIONAL MEASUREMENT TOOL.

    PubMed

    Sleeper, Mark D; Kenyon, Lisa K; Elliott, James M; Cheng, M Samuel

    2016-12-01

    Despite the availability of various field-tests for many competitive sports, a reliable and valid test specifically developed for use in men's gymnastics has not yet been developed. The Men's Gymnastics Functional Measurement Tool (MGFMT) was designed to assess sport-specific physical abilities in male competitive gymnasts. The purpose of this study was to develop the MGFMT by establishing a scoring system for individual test items and to initiate the process of establishing test-retest reliability and construct validity. A total of 83 competitive male gymnasts ages 7-18 underwent testing using the MGFMT. Thirty of these subjects underwent re-testing one week later in order to assess test-retest reliability. Construct validity was assessed using a simple regression analysis between total MGFMT scores and the gymnasts' USA-Gymnastics competitive level to calculate the coefficient of determination (r 2 ). Test-retest reliability was analyzed using Model 1 Intraclass correlation coefficients (ICC). Statistical significance was set at the p<0.05 level. The relationship between total MGFMT scores and subjects' current USA-Gymnastics competitive level was found to be good (r 2  = 0.63). Reliability testing of the MGFMT composite test score showed excellent test-retest reliability over a one-week period (ICC = 0.97). Test-retest reliability of the individual component tests ranged from good to excellent (ICC = 0.75-0.97). The results of this study provide initial support for the construct validity and test-retest reliability of the MGFMT. Level 3.

  15. Hybrid automated reliability predictor integrated work station (HiREL)

    NASA Technical Reports Server (NTRS)

    Bavuso, Salvatore J.

    1991-01-01

    The Hybrid Automated Reliability Predictor (HARP) integrated reliability (HiREL) workstation tool system marks another step toward the goal of producing a totally integrated computer aided design (CAD) workstation design capability. Since a reliability engineer must generally graphically represent a reliability model before he can solve it, the use of a graphical input description language increases productivity and decreases the incidence of error. The captured image displayed on a cathode ray tube (CRT) screen serves as a documented copy of the model and provides the data for automatic input to the HARP reliability model solver. The introduction of dependency gates to a fault tree notation allows the modeling of very large fault tolerant system models using a concise and visually recognizable and familiar graphical language. In addition to aiding in the validation of the reliability model, the concise graphical representation presents company management, regulatory agencies, and company customers a means of expressing a complex model that is readily understandable. The graphical postprocessor computer program HARPO (HARP Output) makes it possible for reliability engineers to quickly analyze huge amounts of reliability/availability data to observe trends due to exploratory design changes.

  16. Reliability of McConnell's classification of patellar orientation in symptomatic and asymptomatic subjects.

    PubMed

    Watson, C J; Propps, M; Galt, W; Redding, A; Dobbs, D

    1999-07-01

    Test-retest reliability study with blinded testers. To determine the intratester reliability of the McConnell classification system and to determine whether the intertester reliability of this system would be improved by one-on-one training of the testers, increasing the variability and numbers of subjects, blinding the testers to the absence or presence of patellofemoral pain syndrome, and adhering to the McConnell classification system as it is taught in the "McConnell Patellofemoral Treatment Plan" continuing education course. The McConnell classification system is currently used by physical therapy clinicians to quantify static patellar orientation. The measurements generated from this system purportedly guide the therapist in the application of patellofemoral tape and in assessment of the efficacy of treatment interventions on changing patellar orientation. Fifty-six subjects (age range, 21-65 years) provided a total of 101 knees for assessment. Seventy-six knees did not produce symptoms. A researcher who did not participate in the measuring process determined that 17 subjects had patellofemoral pain syndrome in 25 knees. Two testers concurrently measured static patellar orientation (anterior/posterior and medial/lateral tilt, medial/lateral glide, and patellar rotation) on subjects, using the McConnell classification system. Repeat measures were performed 3-7 days later. A kappa (kappa) statistic was used to assess the degree of agreement within each tester and between testers. The kappa coefficients for intratester reliability varied from -0.06 to 0.35. Intertester reliability ranged from -0.03 to 0.19. The McConnell classification system, in its current form, does not appear to be very reliable. Intratester reliability ranged from poor to fair, and intertester reliability was poor to slight. This system should not be used as a measurement tool or as a basis for treatment decisions.

  17. ETARA PC version 3.3 user's guide: Reliability, availability, maintainability simulation model

    NASA Technical Reports Server (NTRS)

    Hoffman, David J.; Viterna, Larry A.

    1991-01-01

    A user's manual describing an interactive, menu-driven, personal computer based Monte Carlo reliability, availability, and maintainability simulation program called event time availability reliability (ETARA) is discussed. Given a reliability block diagram representation of a system, ETARA simulates the behavior of the system over a specified period of time using Monte Carlo methods to generate block failure and repair intervals as a function of exponential and/or Weibull distributions. Availability parameters such as equivalent availability, state availability (percentage of time as a particular output state capability), continuous state duration and number of state occurrences can be calculated. Initial spares allotment and spares replenishment on a resupply cycle can be simulated. The number of block failures are tabulated both individually and by block type, as well as total downtime, repair time, and time waiting for spares. Also, maintenance man-hours per year and system reliability, with or without repair, at or above a particular output capability can be calculated over a cumulative period of time or at specific points in time.

  18. Metrics for Assessing the Reliability of a Telemedicine Remote Monitoring System

    PubMed Central

    Fox, Mark; Papadopoulos, Amy; Crump, Cindy

    2013-01-01

    Abstract Objective: The goal of this study was to assess using new metrics the reliability of a real-time health monitoring system in homes of older adults. Materials and Methods: The “MobileCare Monitor” system was installed into the homes of nine older adults >75 years of age for a 2-week period. The system consisted of a wireless wristwatch-based monitoring system containing sensors for location, temperature, and impacts and a “panic” button that was connected through a mesh network to third-party wireless devices (blood pressure cuff, pulse oximeter, weight scale, and a survey-administering device). To assess system reliability, daily phone calls instructed participants to conduct system tests and reminded them to fill out surveys and daily diaries. Phone reports and participant diary entries were checked against data received at a secure server. Results: Reliability metrics assessed overall system reliability, data concurrence, study effectiveness, and system usability. Except for the pulse oximeter, system reliability metrics varied between 73% and 92%. Data concurrence for proximal and distal readings exceeded 88%. System usability following the pulse oximeter firmware update varied between 82% and 97%. An estimate of watch-wearing adherence within the home was quite high, about 80%, although given the inability to assess watch-wearing when a participant left the house, adherence likely exceeded the 10 h/day requested time. In total, 3,436 of 3,906 potential measurements were obtained, indicating a study effectiveness of 88%. Conclusions: The system was quite effective in providing accurate remote health data. The different system reliability measures identify important error sources in remote monitoring systems. PMID:23611640

  19. Development and validation of a scale for mouth handicap in systemic sclerosis: the Mouth Handicap in Systemic Sclerosis scale

    PubMed Central

    Mouthon, L; Rannou, F; Bérezné, A; Pagnoux, C; Arène, J‐P; Foïs, E; Cabane, J; Guillevin, L; Revel, M; Fermanian, J; Poiraudeau, S

    2007-01-01

    Objective To develop and assess the reliability and construct validity of a scale assessing disability involving the mouth in systemic sclerosis (SSc). Methods We generated a 34‐item provisional scale from mailed responses of patients (n = 74), expert consensus (n = 10) and literature analysis. A total of 71 other SSc patients were recruited. The test–retest reliability was assessed using the intraclass coefficient correlation and divergent validity using the Spearman correlation coefficient. Factor analysis followed by varimax rotation was performed to assess the factorial structure of the scale. Results The item reduction process retained 12 items with 5 levels of answers (total score range 0–48). The mean total score of the scale was 20.3 (SD 9.7). The test–retest reliability was 0.96. Divergent validity was confirmed for global disability (Health Assessment Questionnaire (HAQ), r = 0.33), hand function (Cochin Hand Function Scale, r = 0.37), inter‐incisor distance (r = −0.34), handicap (McMaster‐Toronto Arthritis questionnaire (MACTAR), r = 0.24), depression (Hospital Anxiety and Depression (HAD); HADd, r = 0.26) and anxiety (HADa, r = 0.17). Factor analysis extracted 3 factors with eigenvalues of 4.26, 1.76 and 1.47, explaining 63% of the variance. These 3 factors could be clinically characterised. The first factor (5 items) represents handicap induced by the reduction in mouth opening, the second (5 items) handicap induced by sicca syndrome and the third (2 items) aesthetic concerns. Conclusion We propose a new scale, the Mouth Handicap in Systemic Sclerosis (MHISS) scale, which has excellent reliability and good construct validity, and assesses specifically disability involving the mouth in patients with SSc. PMID:17502364

  20. Reliability and validity of CODA motion analysis system for measuring cervical range of motion in patients with cervical spondylosis and anterior cervical fusion.

    PubMed

    Gao, Zhongyang; Song, Hui; Ren, Fenggang; Li, Yuhuan; Wang, Dong; He, Xijing

    2017-12-01

    The aim of the present study was to evaluate the reliability of the Cartesian Optoelectronic Dynamic Anthropometer (CODA) motion system in measuring the cervical range of motion (ROM) and verify the construct validity of the CODA motion system. A total of 26 patients with cervical spondylosis and 22 patients with anterior cervical fusion were enrolled and the CODA motion analysis system was used to measure the three-dimensional cervical ROM. Intra- and inter-rater reliability was assessed by interclass correlation coefficients (ICCs), standard error of measurement (SEm), Limits of Agreements (LOA) and minimal detectable change (MDC). Independent samples t-tests were performed to examine the differences of cervical ROM between cervical spondylosis and anterior cervical fusion patients. The results revealed that in the cervical spondylosis group, the reliability was almost perfect (intra-rater reliability: ICC, 0.87-0.95; LOA, -12.86-13.70; SEm, 2.97-4.58; inter-rater reliability: ICC, 0.84-0.95; LOA, -13.09-13.48; SEm, 3.13-4.32). In the anterior cervical fusion group, the reliability was high (intra-rater reliability: ICC, 0.88-0.97; LOA, -10.65-11.08; SEm, 2.10-3.77; inter-rater reliability: ICC, 0.86-0.96; LOA, -10.91-13.66; SEm, 2.20-4.45). The cervical ROM in the cervical spondylosis group was significantly higher than that in the anterior cervical fusion group in all directions except for left rotation. In conclusion, the CODA motion analysis system is highly reliable in measuring cervical ROM and the construct validity was verified, as the system was sufficiently sensitive to distinguish between the cervical spondylosis and anterior cervical fusion groups based on their ROM.

  1. Development and validation of a paediatric long-bone fracture classification. A prospective multicentre study in 13 European paediatric trauma centres

    PubMed Central

    2011-01-01

    Background The aim of this study was to develop a child-specific classification system for long bone fractures and to examine its reliability and validity on the basis of a prospective multicentre study. Methods Using the sequentially developed classification system, three samples of between 30 and 185 paediatric limb fractures from a pool of 2308 fractures documented in two multicenter studies were analysed in a blinded fashion by eight orthopaedic surgeons, on a total of 5 occasions. Intra- and interobserver reliability and accuracy were calculated. Results The reliability improved with successive simplification of the classification. The final version resulted in an overall interobserver agreement of κ = 0.71 with no significant difference between experienced and less experienced raters. Conclusions In conclusion, the evaluation of the newly proposed classification system resulted in a reliable and routinely applicable system, for which training in its proper use may further improve the reliability. It can be recommended as a useful tool for clinical practice and offers the option for developing treatment recommendations and outcome predictions in the future. PMID:21548939

  2. Microgrid Analysis Tools Summary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jimenez, Antonio; Haase, Scott G; Mathur, Shivani

    2018-03-05

    The over-arching goal of the Alaska Microgrid Partnership is to reduce the use of total imported fuel into communities to secure all energy services by at least 50% in Alaska's remote microgrids without increasing system life cycle costs while also improving overall system reliability, security, and resilience. One goal of the Alaska Microgrid Partnership is to investigate whether a combination of energy efficiency and high-contribution (from renewable energy) power systems can reduce total imported energy usage by 50% while reducing life cycle costs and improving reliability and resiliency. This presentation provides an overview of the following four renewable energy optimizationmore » tools. Information is from respective tool websites, tool developers, and author experience. Distributed Energy Resources Customer Adoption Model (DER-CAM) Microgrid Design Toolkit (MDT) Renewable Energy Optimization (REopt) Tool Hybrid Optimization Model for Electric Renewables (HOMER).« less

  3. Maximally reliable Markov chains under energy constraints.

    PubMed

    Escola, Sean; Eisele, Michael; Miller, Kenneth; Paninski, Liam

    2009-07-01

    Signal-to-noise ratios in physical systems can be significantly degraded if the outputs of the systems are highly variable. Biological processes for which highly stereotyped signal generations are necessary features appear to have reduced their signal variabilities by employing multiple processing steps. To better understand why this multistep cascade structure might be desirable, we prove that the reliability of a signal generated by a multistate system with no memory (i.e., a Markov chain) is maximal if and only if the system topology is such that the process steps irreversibly through each state, with transition rates chosen such that an equal fraction of the total signal is generated in each state. Furthermore, our result indicates that by increasing the number of states, it is possible to arbitrarily increase the reliability of the system. In a physical system, however, an energy cost is associated with maintaining irreversible transitions, and this cost increases with the number of such transitions (i.e., the number of states). Thus, an infinite-length chain, which would be perfectly reliable, is infeasible. To model the effects of energy demands on the maximally reliable solution, we numerically optimize the topology under two distinct energy functions that penalize either irreversible transitions or incommunicability between states, respectively. In both cases, the solutions are essentially irreversible linear chains, but with upper bounds on the number of states set by the amount of available energy. We therefore conclude that a physical system for which signal reliability is important should employ a linear architecture, with the number of states (and thus the reliability) determined by the intrinsic energy constraints of the system.

  4. Operational present status and reliability analysis of the upgraded EAST cryogenic system

    NASA Astrophysics Data System (ADS)

    Zhou, Z. W.; Y Zhang, Q.; Lu, X. F.; Hu, L. B.; Zhu, P.

    2017-12-01

    Since the first commissioning in 2005, the cryogenic system for EAST (Experimental Advanced Superconducting Tokamak) has been cooled down and warmed up for thirteen experimental campaigns. In order to promote the refrigeration efficiencies and reliability, the EAST cryogenic system was upgraded gradually with new helium screw compressors and new dynamic gas bearing helium turbine expanders with eddy current brake to improve the original poor mechanical and operational performance from 2012 to 2015. Then the totally upgraded cryogenic system was put into operation in the eleventh cool-down experiment, and has been operated for the latest several experimental campaigns. The upgraded system has successfully coped with various normal operational modes during cool-down and 4.5 K steady-state operation under pulsed heat load from the tokamak as well as the abnormal fault modes including turbines protection stop. In this paper, the upgraded EAST cryogenic system including its functional analysis and new cryogenic control networks will be presented in detail. Also, its operational present status in the latest cool-down experiments will be presented and the system reliability will be analyzed, which shows a high reliability and low fault rate after upgrade. In the end, some future necessary work to meet the higher reliability requirement for future uninterrupted long-term experimental operation will also be proposed.

  5. MEASURING SPORT-SPECIFIC PHYSICAL ABILITIES IN MALE GYMNASTS: THE MEN'S GYMNASTICS FUNCTIONAL MEASUREMENT TOOL

    PubMed Central

    Kenyon, Lisa K.; Elliott, James M; Cheng, M. Samuel

    2016-01-01

    Purpose/Background Despite the availability of various field-tests for many competitive sports, a reliable and valid test specifically developed for use in men's gymnastics has not yet been developed. The Men's Gymnastics Functional Measurement Tool (MGFMT) was designed to assess sport-specific physical abilities in male competitive gymnasts. The purpose of this study was to develop the MGFMT by establishing a scoring system for individual test items and to initiate the process of establishing test-retest reliability and construct validity. Methods A total of 83 competitive male gymnasts ages 7-18 underwent testing using the MGFMT. Thirty of these subjects underwent re-testing one week later in order to assess test-retest reliability. Construct validity was assessed using a simple regression analysis between total MGFMT scores and the gymnasts’ USA-Gymnastics competitive level to calculate the coefficient of determination (r2). Test-retest reliability was analyzed using Model 1 Intraclass correlation coefficients (ICC). Statistical significance was set at the p<0.05 level. Results The relationship between total MGFMT scores and subjects’ current USA-Gymnastics competitive level was found to be good (r2 = 0.63). Reliability testing of the MGFMT composite test score showed excellent test-retest reliability over a one-week period (ICC = 0.97). Test-retest reliability of the individual component tests ranged from good to excellent (ICC = 0.75-0.97). Conclusions The results of this study provide initial support for the construct validity and test-retest reliability of the MGFMT. Level of Evidence Level 3 PMID:27999723

  6. Reliable Alignment in Total Knee Arthroplasty by the Use of an iPod-Based Navigation System

    PubMed Central

    Koenen, Paola; Schneider, Marco M.; Fröhlich, Matthias; Driessen, Arne; Bouillon, Bertil; Bäthis, Holger

    2016-01-01

    Axial alignment is one of the main objectives in total knee arthroplasty (TKA). Computer-assisted surgery (CAS) is more accurate regarding limb alignment reconstruction compared to the conventional technique. The aim of this study was to analyse the precision of the innovative navigation system DASH® by Brainlab and to evaluate the reliability of intraoperatively acquired data. A retrospective analysis of 40 patients was performed, who underwent CAS TKA using the iPod-based navigation system DASH. Pre- and postoperative axial alignment were measured on standardized radiographs by two independent observers. These data were compared with the navigation data. Furthermore, interobserver reliability was measured. The duration of surgery was monitored. The mean difference between the preoperative mechanical axis by X-ray and the first intraoperatively measured limb axis by the navigation system was 2.4°. The postoperative X-rays showed a mean difference of 1.3° compared to the final navigation measurement. According to radiographic measurements, 88% of arthroplasties had a postoperative limb axis within ±3°. The mean additional time needed for navigation was 5 minutes. We could prove very good precision for the DASH system, which is comparable to established navigation devices with only negligible expenditure of time compared to conventional TKA. PMID:27313898

  7. Reliability of a Test Battery Designed for Quickly and Safely Assessing Diverse Indices of Neuromuscular Function

    NASA Technical Reports Server (NTRS)

    Spiering, Barry A.; Lee, Stuart M. C.; Mulavara, Ajitkumar P.; Bentley, Jason, R.; Buxton, Roxanne E.; Lawrence, Emily L.; Sinka, Joseph; Guilliams, Mark E.; Ploutz-Snyder, Lori L.; Bloomberg, Jacob J.

    2010-01-01

    Spaceflight affects nearly every physiological system. Spaceflight-induced alterations in physiological function translate to decrements in functional performance. Purpose: To develop a test battery for quickly and safely assessing diverse indices of neuromuscular performance. I. Quickly: Battery of tests can be completed in approx.30-40 min. II. Safely: a) No eccentric muscle actions or impact forces. b) Tests present little challenge to postural stability. III. Diverse indices: a) Strength: Excellent reliability (ICC = 0.99) b) Central activation: Very good reliability (ICC = 0.87) c) Power: Excellent reliability (ICC = 0.99) d) Endurance: Total work has excellent reliability (ICC = 0.99) e) Force steadiness: Poor reliability (ICC = 0.20 - 0.60) National

  8. Selenide isotope generator for the Galileo mission. Reliability program plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1978-10-01

    The reliability program plan for the Selenide Isotope Generator (SIG) program is presented. It delineates the specific tasks that will be accomplished by Teledyne Energy Systems and its suppliers during design, development, fabrication and test of deliverable Radioisotopic Thermoelectric Generators (RTG), Electrical Heated Thermoelectric Generators (ETG) and associated Ground Support Equipment (GSE). The Plan is formulated in general accordance with procedures specified in DOE Reliability Engineering Program Requirements Publication No. SNS-2, dated June 17, 1974. The Reliability Program Plan presented herein defines the total reliability effort without further reference to Government Specifications. The reliability tasks to be accomplished are delineatedmore » herein and become the basis for contract compliance to the extent specified in the SIG contract Statement of Work.« less

  9. Reliability analysis of forty-five strain-gage systems mounted on the first fan stage of a YF-100 engine

    NASA Technical Reports Server (NTRS)

    Holanda, R.; Frause, L. M.

    1977-01-01

    The reliability of 45 state-of-the-art strain gage systems under full scale engine testing was investigated. The flame spray process was used to install 23 systems on the first fan rotor of a YF-100 engine; the others were epoxy cemented. A total of 56 percent of the systems failed in 11 hours of engine operation. Flame spray system failures were primarily due to high gage resistance, probably caused by high stress levels. Epoxy system failures were principally erosion failures, but only on the concave side of the blade. Lead-wire failures between the blade-to-disk jump and the control room could not be analyzed.

  10. A PC program to optimize system configuration for desired reliability at minimum cost

    NASA Technical Reports Server (NTRS)

    Hills, Steven W.; Siahpush, Ali S.

    1994-01-01

    High reliability is desired in all engineered systems. One way to improve system reliability is to use redundant components. When redundant components are used, the problem becomes one of allocating them to achieve the best reliability without exceeding other design constraints such as cost, weight, or volume. Systems with few components can be optimized by simply examining every possible combination but the number of combinations for most systems is prohibitive. A computerized iteration of the process is possible but anything short of a super computer requires too much time to be practical. Many researchers have derived mathematical formulations for calculating the optimum configuration directly. However, most of the derivations are based on continuous functions whereas the real system is composed of discrete entities. Therefore, these techniques are approximations of the true optimum solution. This paper describes a computer program that will determine the optimum configuration of a system of multiple redundancy of both standard and optional components. The algorithm is a pair-wise comparative progression technique which can derive the true optimum by calculating only a small fraction of the total number of combinations. A designer can quickly analyze a system with this program on a personal computer.

  11. Recent Photovoltaic Performance Data in the USA (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jordan, D.

    2014-03-01

    This paper presents performance data from nearly 50,000 Photovoltaic systems totaling 1.7 Gigawatts installed capacity in the USA from 2009 to 2012. 90% of the systems performed to within 10% or better of expected performance. Only 2-4% of the data indicate issues significantly affecting the system performance. Special causes of underperformance and their impacts are delineated by reliability category. Delays and interconnections dominate project-related issues particularly in the first year, but total less than 0.5% of all systems. Hardware-related issues are dominated by inverter problems totaling less than 0.4% and underperforming modules to less than 0.1%.

  12. A Framework For Fault Tolerance In Virtualized Servers

    DTIC Science & Technology

    2016-06-01

    effects into the system. Decrease in performance, the expansion in the total system size and weight, and a hike in the system cost can be counted in... benefit also shines out in terms of reliability. 41 4. How Data Guard Synchronizes Standby Databases Primary and standby databases in Oracle Data

  13. The Italian version of the Mouth Handicap in Systemic Sclerosis scale (MHISS) is valid, reliable and useful in assessing oral health-related quality of life (OHRQoL) in systemic sclerosis (SSc) patients.

    PubMed

    Maddali Bongi, S; Del Rosso, A; Miniati, I; Galluccio, F; Landi, G; Tai, G; Matucci-Cerinic, M

    2012-09-01

    In systemic sclerosis (SSc), mouth and face involvement leads to problems in oral health-related quality of life (OHRQoL). Mouth Handicap in Systemic Sclerosis scale (MHISS) is a 12-item questionnaire specifically quantifying mouth disability in SSc, organized in 3 subscales. Our aim was to validate Italian version of MHISS, by assessing its test-retest reliability and internal and external consistency in Italian SSc patients. Forty SSc patients (7 dSSc, 33 lSSc; age and disease duration: 57.27 ± 11.41, 9.4 ± 4.4 years; 22 with sicca syndrome) were evaluated with MHISS. MHISS was translated following a forward-backward translation procedure, with independent translations and counter-translation. Test-retest reliability was evaluated, comparing the results of two administrations, with intraclass correlation coefficient (ICC). Internal consistency was assessed by Cronbach's α and external consistency by comparison with mouth opening. MHISS has a good test-retest reliability (ICC: 0.93) and internal consistency (Cronbach's α:0.99). A good external consistency was confirmed by correlation with mouth opening (rho: -0,3869, p: 0.0137). Total MHISS score was 17.65 ± 5.20, with scores of subscale 1 (reduced mouth opening) of 6.60 ± 2.85 and scores of subscales 2 (sicca syndrome) and 3 (aesthetic concerns) of 7.82 ± 2.59 and 3.22 ± 1.14. Total and subscale 2 scores are higher in dSSc than in lSSc. This result may be due to the higher presence of sicca syndrome in dSSc than in lSSc (p = 0.0109). Our results support validity and reliability in Italian SSc patients of MHISS, specifically measuring SSc OHRQoL.

  14. Reliability and Maintainability Engineering - A Major Driver for Safety and Affordability

    NASA Technical Reports Server (NTRS)

    Safie, Fayssal M.

    2011-01-01

    The United States National Aeronautics and Space Administration (NASA) is in the midst of an effort to design and build a safe and affordable heavy lift vehicle to go to the moon and beyond. To achieve that, NASA is seeking more innovative and efficient approaches to reduce cost while maintaining an acceptable level of safety and mission success. One area that has the potential to contribute significantly to achieving NASA safety and affordability goals is Reliability and Maintainability (R&M) engineering. Inadequate reliability or failure of critical safety items may directly jeopardize the safety of the user(s) and result in a loss of life. Inadequate reliability of equipment may directly jeopardize mission success. Systems designed to be more reliable (fewer failures) and maintainable (fewer resources needed) can lower the total life cycle cost. The Department of Defense (DOD) and industry experience has shown that optimized and adequate levels of R&M are critical for achieving a high level of safety and mission success, and low sustainment cost. Also, lessons learned from the Space Shuttle program clearly demonstrated the importance of R&M engineering in designing and operating safe and affordable launch systems. The Challenger and Columbia accidents are examples of the severe impact of design unreliability and process induced failures on system safety and mission success. These accidents demonstrated the criticality of reliability engineering in understanding component failure mechanisms and integrated system failures across the system elements interfaces. Experience from the shuttle program also shows that insufficient Reliability, Maintainability, and Supportability (RMS) engineering analyses upfront in the design phase can significantly increase the sustainment cost and, thereby, the total life cycle cost. Emphasis on RMS during the design phase is critical for identifying the design features and characteristics needed for time efficient processing, improved operational availability, and optimized maintenance and logistic support infrastructure. This paper discusses the role of R&M in a program acquisition phase and the potential impact of R&M on safety, mission success, operational availability, and affordability. This includes discussion of the R&M elements that need to be addressed and the R&M analyses that need to be performed in order to support a safe and affordable system design. The paper also provides some lessons learned from the Space Shuttle program on the impact of R&M on safety and affordability.

  15. A pragmatic decision model for inventory management with heterogeneous suppliers

    NASA Astrophysics Data System (ADS)

    Nakandala, Dilupa; Lau, Henry; Zhang, Jingjing; Gunasekaran, Angappa

    2018-05-01

    For enterprises, it is imperative that the trade-off between the cost of inventory and risk implications is managed in the most efficient manner. To explore this, we use the common example of a wholesaler operating in an environment where suppliers demonstrate heterogeneous reliability. The wholesaler has partial orders with dual suppliers and uses lateral transshipments. While supplier reliability is a key concern in inventory management, reliable suppliers are more expensive and investment in strategic approaches that improve supplier performance carries a high cost. Here we consider the operational strategy of dual sourcing with reliable and unreliable suppliers and model the total inventory cost where the likely scenario lead-time of the unreliable suppliers extends beyond the scheduling period. We then develop a Customized Integer Programming Optimization Model to determine the optimum size of partial orders with multiple suppliers. In addition to the objective of total cost optimization, this study takes into account the volatility of the cost associated with the uncertainty of an inventory system.

  16. Inter-rater reliability of a modified version of Delitto et al.’s classification-based system for low back pain: a pilot study

    PubMed Central

    Apeldoorn, Adri T.; van Helvoirt, Hans; Ostelo, Raymond W.; Meihuizen, Hanneke; Kamper, Steven J.; van Tulder, Maurits W.; de Vet, Henrica C. W.

    2016-01-01

    Study design Observational inter-rater reliability study. Objectives To examine: (1) the inter-rater reliability of a modified version of Delitto et al.’s classification-based algorithm for patients with low back pain; (2) the influence of different levels of familiarity with the system; and (3) the inter-rater reliability of algorithm decisions in patients who clearly fit into a subgroup (clear classifications) and those who do not (unclear classifications). Methods Patients were examined twice on the same day by two of three participating physical therapists with different levels of familiarity with the system. Patients were classified into one of four classification groups. Raters were blind to the others’ classification decision. In order to quantify the inter-rater reliability, percentages of agreement and Cohen’s Kappa were calculated. Results A total of 36 patients were included (clear classification n = 23; unclear classification n = 13). The overall rate of agreement was 53% and the Kappa value was 0·34 [95% confidence interval (CI): 0·11–0·57], which indicated only fair inter-rater reliability. Inter-rater reliability for patients with a clear classification (agreement 52%, Kappa value 0·29) was not higher than for patients with an unclear classification (agreement 54%, Kappa value 0·33). Familiarity with the system (i.e. trained with written instructions and previous research experience with the algorithm) did not improve the inter-rater reliability. Conclusion Our pilot study challenges the inter-rater reliability of the classification procedure in clinical practice. Therefore, more knowledge is needed about factors that affect the inter-rater reliability, in order to improve the clinical applicability of the classification scheme. PMID:27559279

  17. A new multi-objective optimization model for preventive maintenance and replacement scheduling of multi-component systems

    NASA Astrophysics Data System (ADS)

    Moghaddam, Kamran S.; Usher, John S.

    2011-07-01

    In this article, a new multi-objective optimization model is developed to determine the optimal preventive maintenance and replacement schedules in a repairable and maintainable multi-component system. In this model, the planning horizon is divided into discrete and equally-sized periods in which three possible actions must be planned for each component, namely maintenance, replacement, or do nothing. The objective is to determine a plan of actions for each component in the system while minimizing the total cost and maximizing overall system reliability simultaneously over the planning horizon. Because of the complexity, combinatorial and highly nonlinear structure of the mathematical model, two metaheuristic solution methods, generational genetic algorithm, and a simulated annealing are applied to tackle the problem. The Pareto optimal solutions that provide good tradeoffs between the total cost and the overall reliability of the system can be obtained by the solution approach. Such a modeling approach should be useful for maintenance planners and engineers tasked with the problem of developing recommended maintenance plans for complex systems of components.

  18. Photovoltaic-Powered Vaccine Refrigerator: Freezer Systems Field Test Results

    NASA Technical Reports Server (NTRS)

    Ratajczak, A. F.

    1985-01-01

    A project to develop and field test photovoltaic-powered refrigerator/freezers suitable for vaccine storage was undertaken. Three refrigerator/freezers were qualified; one by Solar Power Corp. and two by Solvolt. Follow-on contracts were awarded for 19 field test systems and for 10 field test systems. A total of 29 systems were installed in 24 countries between October 1981 and October 1984. The project, systems descriptions, installation experiences, performance data for the 22 systems for which field test data was reported, an operational reliability summary, and recommendations relative to system designs and future use of such systems are explained. Performance data indicate that the systems are highly reliable and are capable of maintaining proper vaccine storage temperatures in a wide range of climatological and user environments.

  19. Digital Avionics Information System (DAIS): Development and Demonstration.

    DTIC Science & Technology

    1981-09-01

    advances in technology. The DAIS architecture results in improved reliability and availability of avionics systems while at the same time reducing life ...DAIS) represents a significant advance in the technology of avionics system architecture. DAIS is a total systems concept, exploiting standardization...configurations and fully capable of accommodating new advances in technology. These fundamental system charac- teristics are described in this report; the

  20. Distribution System Pricing with Distributed Energy Resources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hledik, Ryan; Lazar, Jim; Schwartz, Lisa

    Technological changes in the electric utility industry bring tremendous opportunities and significant challenges. Customers are installing clean sources of on-site generation such as rooftop solar photovoltaic (PV) systems. At the same time, smart appliances and control systems that can communicate with the grid are entering the retail market. Among the opportunities these changes create are a cleaner and more diverse power system, the ability to improve system reliability and system resilience, and the potential for lower total costs. Challenges include integrating these new resources in a way that maintains system reliability, provides an equitable sharing of system costs, and avoidsmore » unbalanced impacts on different groups of customers, including those who install distributed energy resources (DERs) and low-income households who may be the least able to afford the transition.« less

  1. The Reliability and Validity of the Thoracolumbar Injury Classification System in Pediatric Spine Trauma.

    PubMed

    Savage, Jason W; Moore, Timothy A; Arnold, Paul M; Thakur, Nikhil; Hsu, Wellington K; Patel, Alpesh A; McCarthy, Kathryn; Schroeder, Gregory D; Vaccaro, Alexander R; Dimar, John R; Anderson, Paul A

    2015-09-15

    The thoracolumbar injury classification system (TLICS) was evaluated in 20 consecutive pediatric spine trauma cases. The purpose of this study was to determine the reliability and validity of the TLICS in pediatric spine trauma. The TLICS was developed to improve the categorization and management of thoracolumbar trauma. TLICS has been shown to have good reliability and validity in the adult population. The clinical and radiographical findings of 20 pediatric thoracolumbar fractures were prospectively presented to 20 surgeons with disparate levels of training and experience with spinal trauma. These injuries were consecutively scored using the TLICS. Cohen unweighted κ coefficients and Spearman rank order correlation values were calculated for the key parameters (injury morphology, status of posterior ligamentous complex, neurological status, TLICS total score, and proposed management) to assess the inter-rater reliabilities. Five surgeons scored the same cases 3 months later to assess the intra-rater reliability. The actual management of each case was then compared with the treatment recommended by the TLICS algorithm to assess validity. The inter-rater κ statistics of all subgroups (injury morphology, status of the posterior ligamentous complex, neurological status, TLICS total score, and proposed treatment) were within the range of moderate to substantial reproducibility (0.524-0.958). All subgroups had excellent intra-rater reliability (0.748-1.000). The various indices for validity were calculated (80.3% correct, 0.836 sensitivity, 0.785 specificity, 0.676 positive predictive value, 0.899 negative predictive value). Overall, TLICS demonstrated good validity. The TLICS has good reliability and validity when used in the pediatric population. The inter-rater reliability of predicting management and indices for validity are lower than those in adults with thoracolumbar fractures, which is likely due to differences in the way children are treated for certain types of injuries. TLICS can be used to reliably categorize thoracolumbar injuries in the pediatric population; however, modifications may be needed to better guide treatment in this specific patient population. 4.

  2. Comparing Global Positioning System (GPS) and Global Navigation Satellite System (GNSS) Measures of Team Sport Movements.

    PubMed

    Jackson, Benjamin M; Polglaze, Ted; Dawson, Brian; King, Trish; Peeling, Peter

    2018-02-21

    To compare data from conventional GPS and new GNSS-enabled tracking devices, and to examine the inter-unit reliability of GNSS devices. Inter-device differences between 10 Hz GPS and GNSS devices were examined during laps (n=40) of a simulated game circuit (SGC) and during elite hockey matches (n=21); GNSS inter-unit reliability was also examined during the SGC laps. Differences in distance values and measures in three velocity categories (low <3 m.s -1 ; moderate 3-5 m.s -1 ; high >5 m.s -1 ) and acceleration/deceleration counts (>1.46 m.s -2 and < -1.46 m.s -2 ) were examined using one-way ANOVA. Inter-unit GNSS reliability was examined using the coefficient of variation (CV) and intra-class correlation coefficient (ICC). Inter-device differences (P <0.05) were found for measures of peak deceleration, low-speed distance, % total distance at low speed, and deceleration count during the SGC, and for all measures except total distance and low-speed distance during hockey matches. Inter-unit (GNSS) differences (P <0.05) were not found. The CV was below 5% for total distance, average and peak speeds and distance and % total distance of low-speed running. The GNSS devices had a lower HDoP score than GPS devices in all conditions. These findings suggest that GNSS devices may be more sensitive than GPS in quantifying the physical demands of team sport movements, but further study into the accuracy of GNSS devices is required.

  3. Reliability demonstration test for load-sharing systems with exponential and Weibull components

    PubMed Central

    Hu, Qingpei; Yu, Dan; Xie, Min

    2017-01-01

    Conducting a Reliability Demonstration Test (RDT) is a crucial step in production. Products are tested under certain schemes to demonstrate whether their reliability indices reach pre-specified thresholds. Test schemes for RDT have been studied in different situations, e.g., lifetime testing, degradation testing and accelerated testing. Systems designed with several structures are also investigated in many RDT plans. Despite the availability of a range of test plans for different systems, RDT planning for load-sharing systems hasn’t yet received the attention it deserves. In this paper, we propose a demonstration method for two specific types of load-sharing systems with components subject to two distributions: exponential and Weibull. Based on the assumptions and interpretations made in several previous works on such load-sharing systems, we set the mean time to failure (MTTF) of the total system as the demonstration target. We represent the MTTF as a summation of mean time between successive component failures. Next, we introduce generalized test statistics for both the underlying distributions. Finally, RDT plans for the two types of systems are established on the basis of these test statistics. PMID:29284030

  4. Reliability demonstration test for load-sharing systems with exponential and Weibull components.

    PubMed

    Xu, Jianyu; Hu, Qingpei; Yu, Dan; Xie, Min

    2017-01-01

    Conducting a Reliability Demonstration Test (RDT) is a crucial step in production. Products are tested under certain schemes to demonstrate whether their reliability indices reach pre-specified thresholds. Test schemes for RDT have been studied in different situations, e.g., lifetime testing, degradation testing and accelerated testing. Systems designed with several structures are also investigated in many RDT plans. Despite the availability of a range of test plans for different systems, RDT planning for load-sharing systems hasn't yet received the attention it deserves. In this paper, we propose a demonstration method for two specific types of load-sharing systems with components subject to two distributions: exponential and Weibull. Based on the assumptions and interpretations made in several previous works on such load-sharing systems, we set the mean time to failure (MTTF) of the total system as the demonstration target. We represent the MTTF as a summation of mean time between successive component failures. Next, we introduce generalized test statistics for both the underlying distributions. Finally, RDT plans for the two types of systems are established on the basis of these test statistics.

  5. Power transfer systems for future navy helicopters. Final report 25 Jun 70--28 Jun 72

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bossler, R.B. Jr.

    1972-11-01

    The purpose of this program was to conduct an analysis of helicopter power transfer systems (pts), both conventional and advanced concept type, with the objective of reducing specific weights and improving reliability beyond present values. The analysis satisfied requirements specified for a 200,000 pound cargo transport helicopter (CTH), a 70,000 pound heavy assault helicopter, and a 15,000 pound non-combat search and rescue helicopter. Four selected gearing systems (out of seven studied), optimized for lightest weight and equal reliability for the CTH, using component proportioning via stress and stiffness equations, had no significant difference between their aircraft payloads. All optimized ptsmore » were approximately 70% of statistically predicted weight. Reliability increase is predicted via gearbox derating using Weibull relationships. Among advanced concepts, the Turbine Integrated Geared Rotor was competitive for weight, technology availability and reliability increase but handicapped by a special engine requirement. The warm cycle system was found not competitive. Helicopter parametric weight analysis is shown. Advanced development Plans are presented for the pts for the CTH, including total pts system, selected pts components, and scale model flight testing in a Kaman HH2 helicopter.« less

  6. Reliable inverter systems

    NASA Technical Reports Server (NTRS)

    Nagano, S.

    1979-01-01

    Base driver with common-load-current feedback protects paralleled inverter systems from open or short circuits. Circuit eliminates total system oscillation that can occur in conventional inverters because of open circuit in primary transformer winding. Common feedback signal produced by functioning modules forces operating frequency of failed module to coincide with clock drive so module resumes normal operating frequency in spite of open circuit.

  7. Comparison of the Chinese ischemic stroke subclassification and Trial of Org 10172 in acute stroke treatment systems in minor stroke.

    PubMed

    Tan, Sha; Zhang, Lei; Chen, Xiaoyu; Wang, Yanqiang; Lin, Yinyao; Cai, Wei; Shan, Yilong; Qiu, Wei; Hu, Xueqiang; Lu, Zhengqi

    2016-09-06

    The underlying causes of minor stroke are difficult to assess. Here, we evaluate the reliability of the Chinese Ischemic Stroke Subclassification (CISS) system in patients with minor stroke, and compare it to the Trial of Org 10172 in Acute Stroke Treatment (TOAST) system. A total of 320 patients with minor stroke were retrospectively registered and categorized into different subgroups of the CISS and TOAST by two neurologists. Inter- and intra-rater agreement with the two systems were assessed with kappa statistics. The percentage of undetermined etiology (UE) cases in the CISS system was 77.3 % less than that in the TOAST system, which was statistically significant (P < 0.001). The percentage of large artery atherosclerosis (LAA) in the CISS system was 79.7 % more than that in the TOAST system, which was also statistically significant (P < 0.001). The kappa values for inter-examiner agreement were 0.898 (P = 0.031) and 0.732 (P = 0.022) for the CISS and TOAST systems, respectively. The intra-observer reliability indexes were moderate (0.569 for neurologist A, and 0.487 for neurologist B). The CISS and TOAST systems are both reliable in classifying patients with minor stroke. CISS classified more patients into known etiologic categories without sacrificing reliability.

  8. Reliability and cost analysis methods

    NASA Technical Reports Server (NTRS)

    Suich, Ronald C.

    1991-01-01

    In the design phase of a system, how does a design engineer or manager choose between a subsystem with .990 reliability and a more costly subsystem with .995 reliability? When is the increased cost justified? High reliability is not necessarily an end in itself but may be desirable in order to reduce the expected cost due to subsystem failure. However, this may not be the wisest use of funds since the expected cost due to subsystem failure is not the only cost involved. The subsystem itself may be very costly. We should not consider either the cost of the subsystem or the expected cost due to subsystem failure separately but should minimize the total of the two costs, i.e., the total of the cost of the subsystem plus the expected cost due to subsystem failure. This final report discusses the Combined Analysis of Reliability, Redundancy, and Cost (CARRAC) methods which were developed under Grant Number NAG 3-1100 from the NASA Lewis Research Center. CARRAC methods and a CARRAC computer program employ five models which can be used to cover a wide range of problems. The models contain an option which can include repair of failed modules.

  9. The reliability and validity of subjective notational analysis in comparison to global positioning system tracking to assess athlete movement patterns.

    PubMed

    Doğramac, Sera N; Watsford, Mark L; Murphy, Aron J

    2011-03-01

    Subjective notational analysis can be used to track players and analyse movement patterns during match-play of team sports such as futsal. The purpose of this study was to establish the validity and reliability of the Event Recorder for subjective notational analysis. A course was designed, replicating ten minutes of futsal match-play movement patterns, where ten participants undertook the course. The course allowed a comparison of data derived from subjective notational analysis, to the known distances of the course, and to GPS data. The study analysed six locomotor activity categories, focusing on total distance covered, total duration of activities and total frequency of activities. The values between the known measurements and the Event Recorder were similar, whereas the majority of significant differences were found between the Event Recorder and GPS values. The reliability of subjective notational analysis was established with all ten participants being analysed on two occasions, as well as analysing five random futsal players twice during match-play. Subjective notational analysis is a valid and reliable method of tracking player movements, and may be a preferred and more effective method than GPS, particularly for indoor sports such as futsal, and field sports where short distances and changes in direction are observed.

  10. Different Approaches for Ensuring Performance/Reliability of Plastic Encapsulated Microcircuits (PEMs) in Space Applications

    NASA Technical Reports Server (NTRS)

    Gerke, R. David; Sandor, Mike; Agarwal, Shri; Moor, Andrew F.; Cooper, Kim A.

    2000-01-01

    Engineers within the commercial and aerospace industries are using trade-off and risk analysis to aid in reducing spacecraft system cost while increasing performance and maintaining high reliability. In many cases, Commercial Off-The-Shelf (COTS) components, which include Plastic Encapsulated Microcircuits (PEMs), are candidate packaging technologies for spacecrafts due to their lower cost, lower weight and enhanced functionality. Establishing and implementing a parts program that effectively and reliably makes use of these potentially less reliable, but state-of-the-art devices, has become a significant portion of the job for the parts engineer. Assembling a reliable high performance electronic system, which includes COTS components, requires that the end user assume a risk. To minimize the risk involved, companies have developed methodologies by which they use accelerated stress testing to assess the product and reduce the risk involved to the total system. Currently, there are no industry standard procedures for accomplishing this risk mitigation. This paper will present the approaches for reducing the risk of using PEMs devices in space flight systems as developed by two independent Laboratories. The JPL procedure involves primarily a tailored screening with accelerated stress philosophy while the APL procedure is primarily, a lot qualification procedure. Both Laboratories successfully have reduced the risk of using the particular devices for their respective systems and mission requirements.

  11. Does the Modified Gartland Classification Clarify Decision Making?

    PubMed

    Leung, Sophia; Paryavi, Ebrahim; Herman, Martin J; Sponseller, Paul D; Abzug, Joshua M

    2018-01-01

    The modified Gartland classification system for pediatric supracondylar fractures is often utilized as a communication tool to aid in determining whether or not a fracture warrants operative intervention. This study sought to determine the interobserver and intraobserver reliability of the Gartland classification system, as well as to determine whether there was agreement that a fracture warranted operative intervention regardless of the classification system. A total of 200 anteroposterior and lateral radiographs of pediatric supracondylar humerus fractures were retrospectively reviewed by 3 fellowship-trained pediatric orthopaedic surgeons and 2 orthopaedic residents and then classified as type I, IIa, IIb, or III. The surgeons then recorded whether they would treat the fracture nonoperatively or operatively. The κ coefficients were calculated to determine interobserver and intraobserver reliability. Overall, the Wilkins-modified Gartland classification has low-moderate interobserver reliability (κ=0.475) and high intraobserver reliability (κ=0.777). A low interobserver reliability was found when differentiating between type IIa and IIb (κ=0.240) among attendings. There was moderate-high interobserver reliability for the decision to operate (κ=0.691) and high intraobserver reliability (κ=0.760). Decreased interobserver reliability was present for decision to operate among residents. For fractures classified as type I, the decision to operate was made 3% of the time and 27% for type IIa. The decision was made to operate 99% of the time for type IIb and 100% for type III. There is almost full agreement for the nonoperative treatment of Type I fractures and operative treatment for type III fractures. There is agreement that type IIb fractures should be treated operatively and that the majority of type IIa fractures should be treated nonoperatively. However, the interobserver reliability for differentiating between type IIa and IIb fractures is low. Our results validate the Gartland classfication system as a method to help direct treatment of pediatric supracondylar humerus fractures, although the modification of the system, IIa versus IIb, seems to have limited reliability and utility. Terminology based on decision to treat may lead to a more clinically useful classification system in the evaluation and treatment of pediatric supracondylar humerus fractures. Level III-diagnostic studies.

  12. Reliability Analysis and Optimal Release Problem Considering Maintenance Time of Software Components for an Embedded OSS Porting Phase

    NASA Astrophysics Data System (ADS)

    Tamura, Yoshinobu; Yamada, Shigeru

    OSS (open source software) systems which serve as key components of critical infrastructures in our social life are still ever-expanding now. Especially, embedded OSS systems have been gaining a lot of attention in the embedded system area, i.e., Android, BusyBox, TRON, etc. However, the poor handling of quality problem and customer support prohibit the progress of embedded OSS. Also, it is difficult for developers to assess the reliability and portability of embedded OSS on a single-board computer. In this paper, we propose a method of software reliability assessment based on flexible hazard rates for the embedded OSS. Also, we analyze actual data of software failure-occurrence time-intervals to show numerical examples of software reliability assessment for the embedded OSS. Moreover, we compare the proposed hazard rate model for the embedded OSS with the typical conventional hazard rate models by using the comparison criteria of goodness-of-fit. Furthermore, we discuss the optimal software release problem for the porting-phase based on the total expected software maintenance cost.

  13. The "Good, Bad and Ugly" pin site grading system: A reliable and memorable method for documenting and monitoring ring fixator pin sites.

    PubMed

    Clint, S A; Eastwood, D M; Chasseaud, M; Calder, P R; Marsh, D R

    2010-02-01

    Although there is much in the literature regarding pin site infections, there is no accepted, validated method for documenting their state. We present a system for reliably labelling pin sites on any ring fixator construct and an easy-to-remember grading system to document the state of each pin site. Each site is graded in terms of erythema, pain and discharge to give a 3-point scale, named "Good", "Bad" and "Ugly" for ease of recall. This system was tested for intra- and inter-observer reproducibility. 15 patients undergoing elective limb reconstruction were recruited. A total of 218 pin sites were independently scored by 2 examiners. 82 were then re-examined later by the same examiners. 514 pin sites were felt to be "Good", 80 "Bad" and 6 "Ugly". The reproducibility of the system was found to be excellent. We feel our system gives a quick, reliable and reproducible method to monitor individual pin sites and their response to treatment. Crown Copyright 2009. Published by Elsevier Ltd. All rights reserved.

  14. Robotic-Assisted Knee Arthroplasty: An Overview.

    PubMed

    van der List, Jelle P; Chawla, Harshvardhan; Pearle, Andrew D

    2016-01-01

    Unicompartmental knee arthroplasty and total knee arthroplasty are reliable treatment options for osteoarthritis. In order to improve survivorship rates, variables that are intraoperatively controlled by the orthopedic surgeon are being evaluated. These variables include lower leg alignment, soft tissue balance, joint line maintenance, and tibial and femoral component alignment, size, and fixation methods. Since tighter control of these factors is associated with improved outcomes of knee arthroplasty, several computer-assisted surgery systems have been developed. These systems differ in the number and type of variables they control. Robotic-assisted systems control these aforementioned variables and, in addition, aim to improve the surgical precision of the procedure. Robotic-assisted systems are active, semi-active, or passive, depending on how independently the systems perform maneuvers. Reviewing the robotic-assisted knee arthroplasty systems, it becomes clear that these systems can accurately and reliably control the aforementioned variables. Moreover, these systems are more accurate and reliable in controlling these variables when compared to the current gold standard of conventional manual surgery. At present, few studies have assessed the survivorship and functional outcomes of robotic-assisted surgery, and no sufficiently powered studies were identified that compared survivorship or functional outcomes between robotic-assisted and conventional knee arthroplasty. Although preliminary outcomes of robotic-assisted surgery look promising, more studies are necessary to assess if the increased accuracy and reliability in controlling the surgical variables leads to better outcomes of robotic-assisted knee arthroplasty.

  15. The interrater reliability of DSM III in children.

    PubMed

    Werry, J S; Methven, R J; Fitzpatrick, J; Dixon, H

    1983-09-01

    A total of 195 admissions to a child psychiatric inpatient unit were diagnosed independently by two to four clinicians on the basis of case presentations at the first ward-round after admission. The DSM III as a whole and the major categories were of high or acceptable reliability, though a few were clearly unreliable. The results are generally consistent with other studies. Unlike other studies, the subcategories were examined and found to vary widely in reliability both as a whole across the system and within parent major categories, throwing considerable doubt upon their utility. The results indicate the need both for improved diagnostic data-gathering techniques in child psychiatry and for more better-designed studies of reliability and, most necessarily, of validity.

  16. Pre-Proposal Assessment of Reliability for Spacecraft Docking with Limited Information

    NASA Technical Reports Server (NTRS)

    Brall, Aron

    2013-01-01

    This paper addresses the problem of estimating the reliability of a critical system function as well as its impact on the system reliability when limited information is available. The approach addresses the basic function reliability, and then the impact of multiple attempts to accomplish the function. The dependence of subsequent attempts on prior failure to accomplish the function is also addressed. The autonomous docking of two spacecraft was the specific example that generated the inquiry, and the resultant impact on total reliability generated substantial interest in presenting the results due to the relative insensitivity of overall performance to basic function reliability and moderate degradation given sufficient attempts to try and accomplish the required goal. The application of the methodology allows proper emphasis on the characteristics that can be estimated with some knowledge, and to insulate the integrity of the design from those characteristics that can't be properly estimated with any rational value of uncertainty. The nature of NASA's missions contains a great deal of uncertainty due to the pursuit of new science or operations. This approach can be applied to any function where multiple attempts at success, with or without degradation, are allowed.

  17. Safety, reliability, maintainability and quality provisions for the Space Shuttle program

    NASA Technical Reports Server (NTRS)

    1990-01-01

    This publication establishes common safety, reliability, maintainability and quality provisions for the Space Shuttle Program. NASA Centers shall use this publication both as the basis for negotiating safety, reliability, maintainability and quality requirements with Shuttle Program contractors and as the guideline for conduct of program safety, reliability, maintainability and quality activities at the Centers. Centers shall assure that applicable provisions of the publication are imposed in lower tier contracts. Centers shall give due regard to other Space Shuttle Program planning in order to provide an integrated total Space Shuttle Program activity. In the implementation of safety, reliability, maintainability and quality activities, consideration shall be given to hardware complexity, supplier experience, state of hardware development, unit cost, and hardware use. The approach and methods for contractor implementation shall be described in the contractors safety, reliability, maintainability and quality plans. This publication incorporates provisions of NASA documents: NHB 1700.1 'NASA Safety Manual, Vol. 1'; NHB 5300.4(IA), 'Reliability Program Provisions for Aeronautical and Space System Contractors'; and NHB 5300.4(1B), 'Quality Program Provisions for Aeronautical and Space System Contractors'. It has been tailored from the above documents based on experience in other programs. It is intended that this publication be reviewed and revised, as appropriate, to reflect new experience and to assure continuing viability.

  18. An adaptive cubature formula for efficient reliability assessment of nonlinear structural dynamic systems

    NASA Astrophysics Data System (ADS)

    Xu, Jun; Kong, Fan

    2018-05-01

    Extreme value distribution (EVD) evaluation is a critical topic in reliability analysis of nonlinear structural dynamic systems. In this paper, a new method is proposed to obtain the EVD. The maximum entropy method (MEM) with fractional moments as constraints is employed to derive the entire range of EVD. Then, an adaptive cubature formula is proposed for fractional moments assessment involved in MEM, which is closely related to the efficiency and accuracy for reliability analysis. Three point sets, which include a total of 2d2 + 1 integration points in the dimension d, are generated in the proposed formula. In this regard, the efficiency of the proposed formula is ensured. Besides, a "free" parameter is introduced, which makes the proposed formula adaptive with the dimension. The "free" parameter is determined by arranging one point set adjacent to the boundary of the hyper-sphere which contains the bulk of total probability. In this regard, the tail distribution may be better reproduced and the fractional moments could be evaluated with accuracy. Finally, the proposed method is applied to a ten-storey shear frame structure under seismic excitations, which exhibits strong nonlinearity. The numerical results demonstrate the efficacy of the proposed method.

  19. Reliability and cross-cultural validation of the Turkish version of Manual Ability Classification System (MACS) for children with cerebral palsy.

    PubMed

    Akpinar, Pinar; Tezel, Canan G; Eliasson, Ann-Christin; Icagasioglu, Afitap

    2010-01-01

    To determine the reliability and cross-cultural validation of the Turkish translation of the Manual Ability Classification System (MACS) for children with cerebral palsy (CP) and to investigate the relation to gross motor function and other comorbidities. After the forward and backward translation procedures, inter-rater and test-retest reliability was assessed between parents, physiotherapists and physicians using the intra-class correlation coefficient (ICC). Children (N = 118, 4 to 18 years, mean age 9 years 4 months; 68 boys, 50 girls) with various types of CP were classified. Additional data on the Gross Motor Function Classification System (GMFCS), intellectual delay, visual acuity, and epilepsy were collected. The inter-rater reliability was high; the ICC ranged from 0.89 to 0.96 among different professionals and parents. Between two persons of the same profession it ranged from 0.97 to 0.98. For the test-retest reliability it ranged from 0.91 to 0.98. Total agreement between the GMFCS and the MACS occurred in only 45% of the children. The level of the MACS was found to correlate with the accompanying comorbidities, namely intellectual delay and epilepsy. The Turkish version of the MACS is found to be valid and reliable, and is suggested to be appropriate for the assessment of manual ability within the Turkish population.

  20. A new MRI rating scale for progressive supranuclear palsy and multiple system atrophy: validity and reliability

    PubMed Central

    Rolland, Yan; Vérin, Marc; Payan, Christine A; Duchesne, Simon; Kraft, Eduard; Hauser, Till K; Jarosz, Josef; Deasy, Neil; Defevbre, Luc; Delmaire, Christine; Dormont, Didier; Ludolph, Albert C; Bensimon, Gilbert

    2011-01-01

    Aim To evaluate a standardised MRI acquisition protocol and a new image rating scale for disease severity in patients with progressive supranuclear palsy (PSP) and multiple systems atrophy (MSA) in a large multicentre study. Methods The MRI protocol consisted of two-dimensional sagittal and axial T1, axial PD, and axial and coronal T2 weighted acquisitions. The 32 item ordinal scale evaluated abnormalities within the basal ganglia and posterior fossa, blind to diagnosis. Among 760 patients in the study population (PSP=362, MSA=398), 627 had per protocol images (PSP=297, MSA=330). Intra-rater (n=60) and inter-rater (n=555) reliability were assessed through Cohen's statistic, and scale structure through principal component analysis (PCA) (n=441). Internal consistency and reliability were checked. Discriminant and predictive validity of extracted factors and total scores were tested for disease severity as per clinical diagnosis. Results Intra-rater and inter-rater reliability were acceptable for 25 (78%) of the items scored (≥0.41). PCA revealed four meaningful clusters of covarying parameters (factor (F) F1: brainstem and cerebellum; F2: midbrain; F3: putamen; F4: other basal ganglia) with good to excellent internal consistency (Cronbach α 0.75–0.93) and moderate to excellent reliability (intraclass coefficient: F1: 0.92; F2: 0.79; F3: 0.71; F4: 0.49). The total score significantly discriminated for disease severity or diagnosis; factorial scores differentially discriminated for disease severity according to diagnosis (PSP: F1–F2; MSA: F2–F3). The total score was significantly related to survival in PSP (p<0.0007) or MSA (p<0.0005), indicating good predictive validity. Conclusions The scale is suitable for use in the context of multicentre studies and can reliably and consistently measure MRI abnormalities in PSP and MSA. Clinical Trial Registration Number The study protocol was filed in the open clinical trial registry (http://www.clinicaltrials.gov) with ID No NCT00211224. PMID:21386111

  1. In vitro and in vivo testing of a totally implantable left ventricular assist system.

    PubMed

    Jassawalla, J S; Daniel, M A; Chen, H; Lee, J; LaForge, D; Billich, J; Ramasamy, N; Miller, P J; Oyer, P E; Portner, P M

    1988-01-01

    The totally implantable Novacor LVAS is being tested under NIH auspices to demonstrate safety and efficacy before clinical trials. Twelve complete systems (submerged in saline at 37 degrees C) are being tested, with an NIH goal of demonstrating 80% reliability for 2 year operation with a 60% confidence level. The systems, which are continuously monitored, are diurnally cycled between two output levels by automatically varying preload and afterload. Currently, 14.3 years of failure-free operation have been accumulated, with a mean duration of 14 months. Using an exponential failure distribution model, the mean time to failure (MTTF) is greater than 8.8 years, corresponding to a demonstrated reliability (for a 2 year mission time) of 80% (80% confidence level). Recent ovine experiments with VAS subsystems include a 767 day volume compensator implant, a 279 day pump/drive unit implant and a 1,448 day BST implant. The last 12 chronic pump/drive unit experiments had a mean duration of 153 days (excluding early postoperative complications). This compares favorably with the NIH goals for complete systems (5 month mean duration). Complete system experiments are currently underway.

  2. Intra- and interobserver reliability of the Eaton classification for trapeziometacarpal arthritis: a systematic review.

    PubMed

    Berger, Aaron J; Momeni, Arash; Ladd, Amy L

    2014-04-01

    Trapeziometacarpal, or thumb carpometacarpal (CMC), arthritis is a common problem with a variety of treatment options. Although widely used, the Eaton radiographic staging system for CMC arthritis is of questionable clinical utility, as disease severity does not predictably correlate with symptoms or treatment recommendations. A possible reason for this is that the classification itself may not be reliable, but the literature on this has not, to our knowledge, been systematically reviewed. We therefore performed a systematic review to determine the intra- and interobserver reliability of the Eaton staging system. We systematically reviewed English-language studies published between 1973 and 2013 to assess the degree of intra- and interobserver reliability of the Eaton classification for determining the stage of trapeziometacarpal joint arthritis and pantrapezial arthritis based on plain radiographic imaging. Search engines included: PubMed, Scopus(®), and CINAHL. Four studies, which included a total of 163 patients, met our inclusion criteria and were evaluated. The level of evidence of the studies included in this analysis was determined using the Oxford Centre for Evidence Based Medicine Levels of Evidence Classification by two independent observers. A limited number of studies have been performed to assess intra- and interobserver reliability of the Eaton classification system. The four studies included were determined to be Level 3b. These studies collectively indicate that the Eaton classification demonstrates poor to fair interobserver reliability (kappa values: 0.11-0.56) and fair to moderate intraobserver reliability (kappa values: 0.54-0.657). Review of the literature demonstrates that radiographs assist in the assessment of CMC joint disease, but there is not a reliable system for classification of disease severity. Currently, diagnosis and treatment of thumb CMC arthritis are based on the surgeon's qualitative assessment combining history, physical examination, and radiographic evaluation. Inconsistent agreement using the current common radiographic classification system suggests a need for better radiographic tools to quantify disease severity.

  3. Upgrading the Extender: Which Options Are Cost-Effective for Modernizing the KC-10

    DTIC Science & Technology

    2011-01-01

    possessed rate is the percent- age of the total fleet that is in depot for heavy maintenance or modifications and not available for missions. The NMC rate...maintainability improvement initiatives. There were none. Table 4.2 shows, for 2004–2008, how much of the total NMC rate was associated with the top five, top...of the total , and the top 100 were responsible for 47 percent. Therefore, reliability and maintainability improvements to many systems would be

  4. Automated Quantification of the Landing Error Scoring System With a Markerless Motion-Capture System.

    PubMed

    Mauntel, Timothy C; Padua, Darin A; Stanley, Laura E; Frank, Barnett S; DiStefano, Lindsay J; Peck, Karen Y; Cameron, Kenneth L; Marshall, Stephen W

    2017-11-01

      The Landing Error Scoring System (LESS) can be used to identify individuals with an elevated risk of lower extremity injury. The limitation of the LESS is that raters identify movement errors from video replay, which is time-consuming and, therefore, may limit its use by clinicians. A markerless motion-capture system may be capable of automating LESS scoring, thereby removing this obstacle.   To determine the reliability of an automated markerless motion-capture system for scoring the LESS.   Cross-sectional study.   United States Military Academy.   A total of 57 healthy, physically active individuals (47 men, 10 women; age = 18.6 ± 0.6 years, height = 174.5 ± 6.7 cm, mass = 75.9 ± 9.2 kg).   Participants completed 3 jump-landing trials that were recorded by standard video cameras and a depth camera. Their movement quality was evaluated by expert LESS raters (standard video recording) using the LESS rubric and by software that automates LESS scoring (depth-camera data). We recorded an error for a LESS item if it was present on at least 2 of 3 jump-landing trials. We calculated κ statistics, prevalence- and bias-adjusted κ (PABAK) statistics, and percentage agreement for each LESS item. Interrater reliability was evaluated between the 2 expert rater scores and between a consensus expert score and the markerless motion-capture system score.   We observed reliability between the 2 expert LESS raters (average κ = 0.45 ± 0.35, average PABAK = 0.67 ± 0.34; percentage agreement = 0.83 ± 0.17). The markerless motion-capture system had similar reliability with consensus expert scores (average κ = 0.48 ± 0.40, average PABAK = 0.71 ± 0.27; percentage agreement = 0.85 ± 0.14). However, reliability was poor for 5 LESS items in both LESS score comparisons.   A markerless motion-capture system had the same level of reliability as expert LESS raters, suggesting that an automated system can accurately assess movement. Therefore, clinicians can use the markerless motion-capture system to reliably score the LESS without being limited by the time requirements of manual LESS scoring.

  5. Optimum testing intervals of building emergency power supply systems in tall buildings in the Hong Kong Special Administrative Region

    NASA Astrophysics Data System (ADS)

    Kwok, Yu Fat

    The main objective of this study is to develop a model for the determination of optimum testing interval (OTI) of non-redundant standby plants. This study focuses on the emergency power generators in tall buildings in Hong Kong. The model for the reliability, which is developed, is applicable to any non-duplicated standby plant. In a tall building, the mobilisation of occupants is constrained by its height and the building internal layout. Occupant's safety, amongst other safety considerations, highly depends on the reliability of the fire detection and protection system, which in turn is dependent on the reliability of the emergency power generation plants. A thorough literature survey shows that the practice used in determining OTI in nuclear plants is generally applicable. Historically, the OTI in these plants is determined by balancing the testing downtime and reliability gained from frequent testing. However, testing downtime does not exist in plants like emergency power generator. Subsequently, sophisticated models have taken repairing downtime into consideration. In this study, the algorithms for the determination of OTI, and hence reliability of standby plants, are reconsidered. A new concept is introduced into the subject. A new model is developed for such purposes which embraces more realistic factors found in practice. System aging and the finite life cycle of the standby plant are considered. Somewhat more pragmatic is that the Optimum Overhauling Interval can also be determined from this new model. System unavailability grow with time, but can be reset by test or overhaul. Contrary to fixed testing intervals, OTI is determined whenever system point unavailability exceeds certain level, which depends on the reliability requirement of the standby system. An optimum testing plan for lowering this level to the 'minimum useful unavailability' level (see section 9.1 for more elaboration) can be determined by the new model presented. Cost effectiveness is accounted for by a new parameter 'tau min', the minimum testing interval (MTI). The MTI optimises the total number of tests and the total number of overhauls, when the costs for each are available. The model sets up criteria for test and overhaul and to 'announce' end of system life. The usefulness of the model is validated by a detailed analysis of the operating parameters from 8,500 maintenance records collected for emergency power generation plants in high rise buildings in Hong Kong. (Abstract shortened by UMI.)

  6. The Verification-based Analysis of Reliable Multicast Protocol

    NASA Technical Reports Server (NTRS)

    Wu, Yunqing

    1996-01-01

    Reliable Multicast Protocol (RMP) is a communication protocol that provides an atomic, totally ordered, reliable multicast service on top of unreliable IP Multicasting. In this paper, we develop formal models for R.W using existing automatic verification systems, and perform verification-based analysis on the formal RMP specifications. We also use the formal models of RW specifications to generate a test suite for conformance testing of the RMP implementation. Throughout the process of RMP development, we follow an iterative, interactive approach that emphasizes concurrent and parallel progress between the implementation and verification processes. Through this approach, we incorporate formal techniques into our development process, promote a common understanding for the protocol, increase the reliability of our software, and maintain high fidelity between the specifications of RMP and its implementation.

  7. Intercommunications in Real Time, Redundant, Distributed Computer System

    NASA Technical Reports Server (NTRS)

    Zanger, H.

    1980-01-01

    An investigation into the applicability of fiber optic communication techniques to real time avionic control systems, in particular the total automatic flight control system used for the VSTOL aircraft is presented. The system consists of spatially distributed microprocessors. The overall control function is partitioned to yield a unidirectional data flow between the processing elements (PE). System reliability is enhanced by the use of triple redundancy. Some general overall system specifications are listed here to provide the necessary background for the requirements of the communications system.

  8. Clinical use of the ABO-Scoring Index: reliability and subtraction frequency.

    PubMed

    Lieber, William S; Carlson, Sean K; Baumrind, Sheldon; Poulton, Donald R

    2003-10-01

    This study tested the reliability and subtraction frequency of the study model-scoring system of the American Board of Orthodontists (ABO). We used a sample of 36 posttreatment study models that were selected randomly from six different orthodontic offices. Intrajudge and interjudge reliability was calculated using nonparametric statistics (Spearman rank coefficient, Wilcoxon, Kruskal-Wallis, and Mann-Whitney tests). We found differences ranging from 3 to 6 subtraction points (total score) for intrajudge scoring between two sessions. For overall total ABO score, the average correlation was .77. Intrajudge correlation was greatest for occlusal relationships and least for interproximal contacts. Interjudge correlation for ABO score averaged r = .85. Correlation was greatest for buccolingual inclination and least for overjet. The data show that some judges, on average, were much more lenient than others and that this resulted in a range of total scores between 19.7 and 27.5. Most of the deductions were found in the buccal segments and most were related to the second molars. We present these findings in the context of clinicians preparing for the ABO phase III examination and for orthodontists in their ongoing evaluation of clinical results.

  9. Highlights of recent balance of system research and evaluation

    NASA Astrophysics Data System (ADS)

    Thomas, M. G.; Stevens, J. W.

    The cost of most photovoltaic (PV) systems is more a function of the balance of system (BOS) components than the collectors. The exception to this rule is the grid-tied system whose cost is related more directly to the collectors, and secondarily to the inverter/controls. In fact, recent procurements throughout the country document that collector costs for roof-mounted, utility-tied systems (Russell, PV Systems Workshop, 7/94) represent 60% to 70% of the system cost. This contrasts with the current market for packaged stand-alone all PV or PV-hybrid systems where collectors represent only 25% to 35% of the total. Not only are the BOS components the cost drivers in the current cost-effective PV system market place, they are also the least reliable components. This paper discusses the impact that BOS issues have on component performance, system performance, and system cost and reliability. We will also look at recent recommended changes in system design based upon performance evaluations of fielded PV systems.

  10. Reliability and Construct Validity of the SENS Motion® Activity Measurement System as a Tool to Detect Sedentary Behaviour in Patients with Knee Osteoarthritis

    PubMed Central

    Gudbergsen, Henrik; Kjærgaard, Morten; Lykkegaard, Kasper Lundberg

    2018-01-01

    Physical inactivity is important to address, and an objective way of measuring inactivity is by accelerometry. The objective of this study was to determine the reliability and construct validity of the SENS motion system to record physical activity and inactivity in patients with knee osteoarthritis. Participants with an age > 40 years and an average weekly pain above 0 on a numeric rating scale (0 = no pain, 10 = worst pain) were included. Participants had a total of two study visits and at each visit participants completed a standardized activity. Data from 24 participants were analysed. A mean agreement of 99% (SD 3%) for sedentary behaviour and a mean agreement of 97% (SD 9%) for active behaviour were found. The agreement for “walking” was 28% (SD 18%). Mean agreement between recordings on the two visits was 96% (SD 8%) for sedentary behaviour and 99% (SD 1%) for active behaviour. The SENS motion activity measurement system can be regarded as a reliable and valid device for measuring sedentary behaviour in patients with knee OA, whereas detection of walking is not reliable and would require further work. PMID:29686901

  11. The Effectiveness of Warranties in the Solar Photovoltaic and Automobile Industries

    NASA Astrophysics Data System (ADS)

    Formica, Tyler J.

    A warranty is an agreement outlined by a manufacturer to a customer that defines performance requirements for a product or service. Although long warranty periods are a useful marketing tool, in 2011 the warranty claims expense was 2.6% of total sales for computer original equipment manufacturers (OEMs) and is over 2% of total sales in many other industries today. Solar PV systems offer inverters with 5-15 year warranties and PV modules with 25-year performance warranties. This is problematic for the return on investment (ROI) of solar PV systems when the modules are still productive and covered under warranty but inverter failures occur due to degradation of electronic components after their warranty has expired. Out-of-warranty inverter failures during the lifetime of solar panels decrease the ROI of solar PV systems significantly and can cause the annual ROI to actually be negative 15-25 years into the lifetime of the system. This thesis analyzes the factors that contribute to designing an optimal warranty period and the relationship between reliability and warranty periods using General Motors (GM) and the solar PV industry as case studies. A return on investment of a solar photovoltaic system is also conducted and the effect of reliability, changing tax credit structures, and failure areas of solar PV systems are analyzed.

  12. Don't Trust a Management Metric, Especially in Life Support

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.

    2014-01-01

    Goodhart's law states that metrics do not work. Metrics become distorted when used and they deflect effort away from more important goals. These well-known and unavoidable problems occurred when the closure and system mass metrics were used to manage life support research. The intent of life support research should be to develop flyable, operable, reliable systems, not merely to increase life support system closure or to reduce its total mass. It would be better to design life support systems to meet the anticipated mission requirements and user needs. Substituting the metrics of closure and total mass for these goals seems to have led life support research to solve the wrong problems.

  13. Clinico-radiological diagnosis and grading of rapidly progressive osteoarthritis of the hip.

    PubMed

    Zazgyva, Ancuţa; Gurzu, Simona; Gergely, István; Jung, Ioan; Roman, Ciprian O; Pop, Tudor S

    2017-03-01

    Due to the current lack of standard definitions for rapidly progressive osteoarthritis of the hip (RPOH) in the literature, this observational study aimed to describe new diagnostic criteria and a grading system for the disease.From a consecutive series of patients undergoing total hip replacement, 2 groups were selected: 1 with RPOH and 1 with primary hip osteoarthritis (POH), and their clinical, paraclinical, and demographic data were compared. The newly proposed clinico-radiological diagnostic criteria are based on characteristics of pain, joint mobility, and radiological assessment. The radiological grading system's inter- and intraobserver reliability was assessed through serial evaluations by 2 blinded reviewers.From the total 863 cases, 82 cases (9.5%) of RPOH were identified and compared with 107 cases of POH. Mean age and disease bilaterality were similar, with a predominance of female patients in the RPOH group (P = 0.03). There were significant differences between the 2 groups in disease onset and aggravation, and intraoperative blood loss. The grading system showed significant inter- and intraobserver agreement (weighted kappa 0.93, and 0.89).Our study presents distinctive, easily recognizable clinico-radiological characteristics of RPOH and confirmed the inter- and intraobserver reliability of the newly proposed grading system.

  14. Methods of measuring pumpage through closed-conduit irrigation systems

    USGS Publications Warehouse

    Kjelstrom, L.C.

    1991-01-01

    Methods of measuring volumes of water withdrawn from the Snake River and its tributaries and pumped through closed-conduit irrigation systems were needed for equitable management of and resolution of conflicts over water use. On the basis of evaluations and field tests by researchers from the University of Idaho, Water Resources Research Institute, Moscow, Idaho, an impeller meter was selected to monitor pumpage through closed-conduit systems. In 1988, impeller meters were installed at 20 pumping stations along the Snake River between the Upper Salmon Falls and C.J. Strike Dams. Impeller-derived pumpage data were adjusted if they differed substantially from ultrasonic flow-meter- or current-meter-derived values. Comparisons of pumpage data obtained by ultrasonic flow-meter and current-meter measurements indicated that the ultrasonic flow meter was a reliable means to check operation of impeller meters. The equipment generally performed satisfactorily, and reliable pumpage data could be obtained using impeller meters in closed-conduit irrigation systems. Many pumping stations that divert water from the Snake River for irrigation remain unmeasured; however, regression analyses indicate that total pumpage can be reasonably estimated on the basis of electrical power consumption data, an approximation of total head at a pumping station, and a derived coefficient.

  15. Spacecraft expected cost analysis with k-out-of-n:G subsystems

    NASA Technical Reports Server (NTRS)

    Patterson, Richard; Suich, Ron

    1991-01-01

    In designing a subsystem for a spacecraft, the design engineer is often faced with a number of options ranging from planning an inexpensive subsystem with low reliability to selecting a highly reliable system that would cost much more. We minimize the total of the cost of the subsytem and the costs that would occur if the subsystem fails. We choose the subsystem with the lowest total. A k-out-of-n:G subsystem has n modules, of which k are required to be good for the subsystem to be good. We examine two models to illustrate the principles of the k-out-of-n:G subsystem designs. For the first model, the following assumptions are necessary: the probability of failure of any module in the system is not affected by the failure of any other module; and each of the modules has the same probabillity of success. For the second model we are also free to choose k in our subsystem.

  16. RT-MATRIX: Measuring Total Organic Carbon by Photocatalytic Oxidation of Volatile Organic Compounds

    NASA Technical Reports Server (NTRS)

    2008-01-01

    Volatile organic compounds (VOCs) inevitably accumulate in enclosed habitats such as the International Space Station and the Crew Exploration Vehicle (CEV) as a result of human metabolism, material off-gassing, and leaking equipment. Some VOCs can negatively affect the quality of the crew's life, health, and performance; and consequently, the success of the mission. Air quality must be closely monitored to ensure a safe living and working environment. Currently, there is no reliable air quality monitoring system that meets NASA's stringent requirements for power, mass, volume, or performance. The ultimate objective of the project -- the development of a Real-Time, Miniaturized, Autonomous Total Risk Indicator System (RT.MATRIX).is to provide a portable, dual-function sensing system that simultaneously determines total organic carbon (TOC) and individual contaminants in air streams.

  17. Estimating spatio-temporal dynamics of stream total phosphate concentration by soft computing techniques.

    PubMed

    Chang, Fi-John; Chen, Pin-An; Chang, Li-Chiu; Tsai, Yu-Hsuan

    2016-08-15

    This study attempts to model the spatio-temporal dynamics of total phosphate (TP) concentrations along a river for effective hydro-environmental management. We propose a systematical modeling scheme (SMS), which is an ingenious modeling process equipped with a dynamic neural network and three refined statistical methods, for reliably predicting the TP concentrations along a river simultaneously. Two different types of artificial neural network (BPNN-static neural network; NARX network-dynamic neural network) are constructed in modeling the dynamic system. The Dahan River in Taiwan is used as a study case, where ten-year seasonal water quality data collected at seven monitoring stations along the river are used for model training and validation. Results demonstrate that the NARX network can suitably capture the important dynamic features and remarkably outperforms the BPNN model, and the SMS can effectively identify key input factors, suitably overcome data scarcity, significantly increase model reliability, satisfactorily estimate site-specific TP concentration at seven monitoring stations simultaneously, and adequately reconstruct seasonal TP data into a monthly scale. The proposed SMS can reliably model the dynamic spatio-temporal water pollution variation in a river system for missing, hazardous or costly data of interest. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Resilience and reliability of compact vertical-flow treatment wetlands designed for tropical climates.

    PubMed

    Lombard-Latune, R; Pelus, L; Fina, N; L'Etang, F; Le Guennec, B; Molle, P

    2018-06-10

    Most of the tropical areas have sanitation problems to contend with. The French system of vertical-flow treatment wetlands (FS-VFTW) fed with raw wastewater could be a good water and sludge management solution. The purpose-adapted tropical design can reduce area requirement to below 1 m 2 /population equivalents (p.e.). The Taupinière FS-VFTW on Martinique Island was built according to this design, with one stage but with a saturated layer at the bottom of the filter and a simplified trickling filter (TF) added for further treatment to meet the high performances targeted. Unsaturated/saturated vertical-flow filters (US/S FS-VFTW) have shown improved performances on total nitrogen, carbon and suspended solids removal in temperate climates, but the performances in tropical conditions remain unknown. Here, we report on real-world-operation in the French Overseas Territories (FOT), the reliability and performances of this VFCW tropical-design. The system experienced loading conditions ranging from 30% to 165% of nominal carbonaceous biological oxygen demand (BOD 5 ), as well as tropical rainstorms that brought over 7 times the nominal hydraulic load. Over a period of 3 years, 29 campaigns collected 24-h flow-proportional samples at each treatment stage (raw wastewater, FS-VFTW outlet, TF outlet). When applied loads were close to nominal values, the US/S FS-VFTW itself guarantees 85/90/60/50% removal and 125/25/40/50 mg/L at the outlet for chemical oxygen demand (COD)/total suspended solids (TSS)/total Kjeldahl nitrogen (TKN)/total nitrogen (TN), respectively. By comparison with US/S systems in mainland France, it appears that the warmer tropical-climate temperatures facilitate both nitrification and denitrification kinetics. Performances in overload conditions confirm that the US/S FS-VFTW remains robust and reliable although COD and TKN removal are impacted, especially after strong tropical rain events. By adding a simple compact trickling filter to a US/S FS-VFTW, the treatment system delivers high-level performances (>95% removal for BOD 5 , COD, TSS and TKN) at less than 1 m 2 /p.e. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Advanced Launch System advanced development oxidizer turbopump program: Technical implementation plan

    NASA Technical Reports Server (NTRS)

    Ferlita, F.

    1989-01-01

    The Advanced Launch Systems (ALS) Advanced Development Oxidizer Turbopump Program has designed, fabricated and demonstrated a low cost, highly reliable oxidizer turbopump for the Space Transportation Engine that minimizes the recurring cost for the ALS engines. Pratt and Whitney's (P and W's) plan for integrating the analyses, testing, fabrication, and other program efforts is addressed. This plan offers a comprehensive description of the total effort required to design, fabricate, and test the ALS oxidizer turbopump. The proposed ALS oxidizer turbopump reduces turbopump costs over current designs by taking advantage of design simplicity and state-of-the-art materials and producibility features without compromising system reliability. This is accomplished by selecting turbopump operating conditions that are within known successful operating regions and by using proven manufacturing techniques.

  20. The specification-based validation of reliable multicast protocol: Problem Report. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Wu, Yunqing

    1995-01-01

    Reliable Multicast Protocol (RMP) is a communication protocol that provides an atomic, totally ordered, reliable multicast service on top of unreliable IP multicasting. In this report, we develop formal models for RMP using existing automated verification systems, and perform validation on the formal RMP specifications. The validation analysis help identifies some minor specification and design problems. We also use the formal models of RMP to generate a test suite for conformance testing of the implementation. Throughout the process of RMP development, we follow an iterative, interactive approach that emphasizes concurrent and parallel progress of implementation and verification processes. Through this approach, we incorporate formal techniques into our development process, promote a common understanding for the protocol, increase the reliability of our software, and maintain high fidelity between the specifications of RMP and its implementation.

  1. Field Programmable Gate Array Reliability Analysis Guidelines for Launch Vehicle Reliability Block Diagrams

    NASA Technical Reports Server (NTRS)

    Al Hassan, Mohammad; Britton, Paul; Hatfield, Glen Spencer; Novack, Steven D.

    2017-01-01

    Field Programmable Gate Arrays (FPGAs) integrated circuits (IC) are one of the key electronic components in today's sophisticated launch and space vehicle complex avionic systems, largely due to their superb reprogrammable and reconfigurable capabilities combined with relatively low non-recurring engineering costs (NRE) and short design cycle. Consequently, FPGAs are prevalent ICs in communication protocols and control signal commands. This paper will identify reliability concerns and high level guidelines to estimate FPGA total failure rates in a launch vehicle application. The paper will discuss hardware, hardware description language, and radiation induced failures. The hardware contribution of the approach accounts for physical failures of the IC. The hardware description language portion will discuss the high level FPGA programming languages and software/code reliability growth. The radiation portion will discuss FPGA susceptibility to space environment radiation.

  2. Reliability generalization study of the Yale-Brown Obsessive-Compulsive Scale for children and adolescents.

    PubMed

    López-Pina, José Antonio; Sánchez-Meca, Julio; López-López, José Antonio; Marín-Martínez, Fulgencio; Núñez-Núñez, Rosa Ma; Rosa-Alcázar, Ana I; Gómez-Conesa, Antonia; Ferrer-Requena, Josefa

    2015-01-01

    The Yale-Brown Obsessive-Compulsive Scale for children and adolescents (CY-BOCS) is a frequently applied test to assess obsessive-compulsive symptoms. We conducted a reliability generalization meta-analysis on the CY-BOCS to estimate the average reliability, search for reliability moderators, and propose a predictive model that researchers and clinicians can use to estimate the expected reliability of the CY-BOCS scores. A total of 47 studies reporting a reliability coefficient with the data at hand were included in the meta-analysis. The results showed good reliability and a large variability associated to the standard deviation of total scores and sample size.

  3. A Physical Heart Failure Simulation System Utilizing the Total Artificial Heart and Modified Donovan Mock Circulation.

    PubMed

    Crosby, Jessica R; DeCook, Katrina J; Tran, Phat L; Betterton, Edward; Smith, Richard G; Larson, Douglas F; Khalpey, Zain I; Burkhoff, Daniel; Slepian, Marvin J

    2017-07-01

    With the growth and diversity of mechanical circulatory support (MCS) systems entering clinical use, a need exists for a robust mock circulation system capable of reliably emulating and reproducing physiologic as well as pathophysiologic states for use in MCS training and inter-device comparison. We report on the development of such a platform utilizing the SynCardia Total Artificial Heart and a modified Donovan Mock Circulation System, capable of being driven at normal and reduced output. With this platform, clinically relevant heart failure hemodynamics could be reliably reproduced as evidenced by elevated left atrial pressure (+112%), reduced aortic flow (-12.6%), blunted Starling-like behavior, and increased afterload sensitivity when compared with normal function. Similarly, pressure-volume relationships demonstrated enhanced sensitivity to afterload and decreased Starling-like behavior in the heart failure model. Lastly, the platform was configured to allow the easy addition of a left ventricular assist device (HeartMate II at 9600 RPM), which upon insertion resulted in improvement of hemodynamics. The present configuration has the potential to serve as a viable system for training and research, aimed at fostering safe and effective MCS device use. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  4. Reliability, Validity, and Responsiveness of InFLUenza Patient-Reported Outcome (FLU-PRO©) Scores in Influenza-Positive Patients.

    PubMed

    Powers, John H; Bacci, Elizabeth D; Guerrero, M Lourdes; Leidy, Nancy Kline; Stringer, Sonja; Kim, Katherine; Memoli, Matthew J; Han, Alison; Fairchok, Mary P; Chen, Wei-Ju; Arnold, John C; Danaher, Patrick J; Lalani, Tahaniyat; Ridoré, Michelande; Burgess, Timothy H; Millar, Eugene V; Hernández, Andrés; Rodríguez-Zulueta, Patricia; Smolskis, Mary C; Ortega-Gallegos, Hilda; Pett, Sarah; Fischer, William; Gillor, Daniel; Macias, Laura Moreno; DuVal, Anna; Rothman, Richard; Dugas, Andrea; Ruiz-Palacios, Guillermo M

    2018-02-01

    To assess the reliability, validity, and responsiveness of InFLUenza Patient-Reported Outcome (FLU-PRO©) scores for quantifying the presence and severity of influenza symptoms. An observational prospective cohort study of adults (≥18 years) with influenza-like illness in the United States, the United Kingdom, Mexico, and South America was conducted. Participants completed the 37-item draft FLU-PRO daily for up to 14 days. Item-level and factor analyses were used to remove items and determine factor structure. Reliability of the final tool was estimated using Cronbach α and intraclass correlation coefficients (2-day reliability). Convergent and known-groups validity and responsiveness were assessed using global assessments of influenza severity and return to usual health. Of the 536 patients enrolled, 221 influenza-positive subjects comprised the analytical sample. The mean age of the patients was 40.7 years, 60.2% were women, and 59.7% were white. The final 32-item measure has six factors/domains (nose, throat, eyes, chest/respiratory, gastrointestinal, and body/systemic), with a higher order factor representing symptom severity overall (comparative fit index = 0.92; root mean square error of approximation = 0.06). Cronbach α was high (total = 0.92; domain range = 0.71-0.87); test-retest reliability (intraclass correlation coefficient, day 1-day 2) was 0.83 for total scores and 0.57 to 0.79 for domains. Day 1 FLU-PRO domain and total scores were moderately to highly correlated (≥0.30) with Patient Global Rating of Flu Severity (except nose and throat). Consistent with known-groups validity, scores differentiated severity groups on the basis of global rating (total: F = 57.2, P < 0.001; domains: F = 8.9-67.5, P < 0.001). Subjects reporting return to usual health showed significantly greater (P < 0.05) FLU-PRO score improvement by day 7 than did those who did not, suggesting score responsiveness. Results suggest that FLU-PRO scores are reliable, valid, and responsive to change in influenza-positive adults. Copyright © 2018 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  5. Translation and cultural adaptation of the Manchester-Oxford Foot Questionnaire (MOXFQ) into Persian language.

    PubMed

    Mousavian, Alireza; Ebrahimzadeh, Mohammad H; Birjandinejad, Ali; Omidi-Kashani, Farzad; Kachooei, Amir Reza

    2015-12-01

    In this study, we aimed to translate and test the validity and reliablity of the Persian version of the Manchester-Oxford Foot Questionnaire in foot and ankle patients. We translated the Manchester-Oxford Foot Questionnaire to Persian language according to the accepted guidelines, then assessed the psychometric properties including the validity and reliability on 308 patients with long-standing foot and ankle problems. To test the reliability, we calculated the intra-class correlation coefficient (ICC) for test-retest reliability and measured Cronbach's alpha to test the internal consistency. To test the construct validity of the Manchester-Oxford Foot Questionnaire we also administered the Short-Form 36 to patients. Construct validity was supported by significant correlation with SF36 subscales except for pain subscale of the persian MOXFQ with mental health of the SF36 (r=0.207). Intraclass correlation coefficient was 0.79 for the total MOXFQ and ranged from 0.83 to 0.89 for the three subscales. Cronbach's alpha for pain, walking/standing, and social interaction was 0.86, 0.88, and 0.89, respectively, and was 0.79 for the total MOXFQ showing good internal consistency in each domain. The Persian Manchester-Oxford Foot Questionnaire health scoring system is a valid and reliable patient-reported instrument for foot and ankle problems. Copyright © 2015. Published by Elsevier Ltd.

  6. Assessing performance of an Electronic Health Record (EHR) using Cognitive Task Analysis.

    PubMed

    Saitwal, Himali; Feng, Xuan; Walji, Muhammad; Patel, Vimla; Zhang, Jiajie

    2010-07-01

    Many Electronic Health Record (EHR) systems fail to provide user-friendly interfaces due to the lack of systematic consideration of human-centered computing issues. Such interfaces can be improved to provide easy to use, easy to learn, and error-resistant EHR systems to the users. To evaluate the usability of an EHR system and suggest areas of improvement in the user interface. The user interface of the AHLTA (Armed Forces Health Longitudinal Technology Application) was analyzed using the Cognitive Task Analysis (CTA) method called GOMS (Goals, Operators, Methods, and Selection rules) and an associated technique called KLM (Keystroke Level Model). The GOMS method was used to evaluate the AHLTA user interface by classifying each step of a given task into Mental (Internal) or Physical (External) operators. This analysis was performed by two analysts independently and the inter-rater reliability was computed to verify the reliability of the GOMS method. Further evaluation was performed using KLM to estimate the execution time required to perform the given task through application of its standard set of operators. The results are based on the analysis of 14 prototypical tasks performed by AHLTA users. The results show that on average a user needs to go through 106 steps to complete a task. To perform all 14 tasks, they would spend about 22 min (independent of system response time) for data entry, of which 11 min are spent on more effortful mental operators. The inter-rater reliability analysis performed for all 14 tasks was 0.8 (kappa), indicating good reliability of the method. This paper empirically reveals and identifies the following finding related to the performance of AHLTA: (1) large number of average total steps to complete common tasks, (2) high average execution time and (3) large percentage of mental operators. The user interface can be improved by reducing (a) the total number of steps and (b) the percentage of mental effort, required for the tasks. 2010 Elsevier Ireland Ltd. All rights reserved.

  7. Performance of the inFLUenza Patient-Reported Outcome (FLU-PRO) diary in patients with influenza-like illness (ILI)

    PubMed Central

    Bacci, Elizabeth D.; Leidy, Nancy K.; Poon, Jiat-Ling; Stringer, Sonja; Memoli, Matthew J.; Han, Alison; Fairchok, Mary P.; Coles, Christian; Owens, Jackie; Chen, Wei-Ju; Arnold, John C.; Danaher, Patrick J.; Lalani, Tahaniyat; Burgess, Timothy H.; Millar, Eugene V.; Ridore, Michelande; Hernández, Andrés; Rodríguez-Zulueta, Patricia; Ortega-Gallegos, Hilda; Galindo-Fraga, Arturo; Ruiz-Palacios, Guillermo M.; Pett, Sarah; Fischer, William; Gillor, Daniel; Moreno Macias, Laura; DuVal, Anna; Rothman, Richard; Dugas, Andrea; Guerrero, M. Lourdes

    2018-01-01

    Background The inFLUenza Patient Reported Outcome (FLU-PRO) measure is a daily diary assessing signs/symptoms of influenza across six body systems: Nose, Throat, Eyes, Chest/Respiratory, Gastrointestinal, Body/Systemic, developed and tested in adults with influenza. Objectives This study tested the reliability, validity, and responsiveness of FLU-PRO scores in adults with influenza-like illness (ILI). Methods Data from the prospective, observational study used to develop and test the FLU-PRO in influenza virus positive patients were analyzed. Adults (≥18 years) presenting with influenza symptoms in outpatient settings in the US, UK, Mexico, and South America were enrolled, tested for influenza virus, and asked to complete the 37-item draft FLU-PRO daily for up to 14-days. Analyses were performed on data from patients testing negative. Reliability of the final, 32-item FLU-PRO was estimated using Cronbach’s alpha (α; Day 1) and intraclass correlation coefficients (ICC; 2-day reproducibility). Convergent and known-groups validity were assessed using patient global assessments of influenza severity (PGA). Patient report of return to usual health was used to assess responsiveness (Day 1–7). Results The analytical sample included 220 ILI patients (mean age = 39.3, 64.1% female, 88.6% white). Sixty-one (28%) were hospitalized at some point in their illness. Internal consistency reliability (α) of FLU-PRO Total score was 0.90 and ranged from 0.72–0.86 for domain scores. Reproducibility (Day 1–2) was 0.64 for Total, ranging from 0.46–0.78 for domain scores. Day 1 FLU-PRO scores correlated (≥0.30) with the PGA (except Gastrointestinal) and were significantly different across PGA severity groups (Total: F = 81.7, p<0.001; subscales: F = 6.9–62.2; p<0.01). Mean score improvements Day 1–7 were significantly greater in patients reporting return to usual health compared with those who did not (p<0.05, Total and subscales, except Gastrointestinal and Eyes). Conclusions Results suggest FLU-PRO scores are reliable, valid, and responsive in adults with influenza-like illness. PMID:29566007

  8. An anatomical subunit-based outcome assessment scale for bilateral cleft lip and palate.

    PubMed

    Bonanthaya, K; Shetty, P N; Fudalej, P S; Rao, D D; Bitra, S; Pabari, M; Rachwalski, M

    2017-08-01

    As there is currently no internationally accepted outcome measurement tool available for complete bilateral cleft lip and palate (CBCLP), the goal of this prospective study was to develop a numerical evaluation scale that allows reliable scoring of this cleft deformity. Our cohort comprised 121 Indian subjects with CBCLP who underwent surgical repair (mean age at time of surgery 6.53 months) using a modified Millard technique. A panel of three professionals evaluated each subject's outcome of bilateral cleft lip repair 6 months postoperatively on two-dimensional (2D) full-face photographs in the frontal view and worm's eye view. A simple two-point rating system was applied to separately analyse a total of 12 components of lip, nose, and scar. The results and mean scores for the analysed anatomical areas were 2.2±1.01 (max=3) for nose, 5.4±1.54 (max=8) for lip, and 1.9±1.3 (max=3) for scar, with a total score 7.7±2.21 (max=12) indicating a good surgical outcome. The inter-examiner ICC for nose, lip, scar, and total score was calculated at 0.836, 0.889, 0.723, and 0.927 respectively and indicated a strong level of repeatability and reliability that was highly significant (P<0.001). In conclusion, we were able to develop and test a scoring system for measuring outcomes in CBCLP that warrants simplicity of use, reliability and reproducibility. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  9. Addressing the Influence of Space Weather on Airline Navigation

    NASA Technical Reports Server (NTRS)

    Sparks, Lawrence

    2012-01-01

    The advent of satellite-based augmentation systems has made it possible to navigate aircraft safely using radio signals emitted by global navigation satellite systems (GNSS) such as the Global Positioning System. As a signal propagates through the earth's ionosphere, it suffers delay that is proportional to the total electron content encountered along the raypath. Since the magnitude of this total electron content is strongly influenced by space weather, the safety and reliability of GNSS for airline navigation requires continual monitoring of the state of the ionosphere and calibration of ionospheric delay. This paper examines the impact of space weather on GNSS-based navigation and provides an overview of how the Wide Area Augmentation System protects its users from positioning error due to ionospheric disturbances

  10. The Yale-Brown Obsessive Compulsive Scale: A Reliability Generalization Meta-Analysis.

    PubMed

    López-Pina, José Antonio; Sánchez-Meca, Julio; López-López, José Antonio; Marín-Martínez, Fulgencio; Núñez-Núñez, Rosa Maria; Rosa-Alcázar, Ana I; Gómez-Conesa, Antonia; Ferrer-Requena, Josefa

    2015-10-01

    The Yale-Brown Obsessive Compulsive Scale (Y-BOCS) is the most frequently applied test to assess obsessive compulsive symptoms. We conducted a reliability generalization meta-analysis on the Y-BOCS to estimate the average reliability, examine the variability among the reliability estimates, search for moderators, and propose a predictive model that researchers and clinicians can use to estimate the expected reliability of the Y-BOCS. We included studies where the Y-BOCS was applied to a sample of adults and reliability estimate was reported. Out of the 11,490 references located, 144 studies met the selection criteria. For the total scale, the mean reliability was 0.866 for coefficients alpha, 0.848 for test-retest correlations, and 0.922 for intraclass correlations. The moderator analyses led to a predictive model where the standard deviation of the total test and the target population (clinical vs. nonclinical) explained 38.6% of the total variability among coefficients alpha. Finally, clinical implications of the results are discussed. © The Author(s) 2014.

  11. An adequacy-constrained integrated planning method for effective accommodation of DG and electric vehicles in smart distribution systems

    NASA Astrophysics Data System (ADS)

    Tan, Zhukui; Xie, Baiming; Zhao, Yuanliang; Dou, Jinyue; Yan, Tong; Liu, Bin; Zeng, Ming

    2018-06-01

    This paper presents a new integrated planning framework for effective accommodating electric vehicles in smart distribution systems (SDS). The proposed method incorporates various investment options available for the utility collectively, including distributed generation (DG), capacitors and network reinforcement. Using a back-propagation algorithm combined with cost-benefit analysis, the optimal network upgrade plan, allocation and sizing of the selected components are determined, with the purpose of minimizing the total system capital and operating costs of DG and EV accommodation. Furthermore, a new iterative reliability test method is proposed. It can check the optimization results by subsequently simulating the reliability level of the planning scheme, and modify the generation reserve margin to guarantee acceptable adequacy levels for each year of the planning horizon. Numerical results based on a 32-bus distribution system verify the effectiveness of the proposed method.

  12. NASCOM network: Ground communications reliability report

    NASA Technical Reports Server (NTRS)

    1973-01-01

    A reliability performance analysis of the NASCOM Network circuits is reported. Network performance narrative summary is presented to include significant changes in circuit configurations, current figures, and trends in each trouble category with notable circuit totals specified. Lost time and interruption tables listing circuits which were affected by outages showing their totals category are submitted. A special analysis of circuits with low reliabilities is developed with tables depicting the performance and graphs for individual reliabilities.

  13. Development of a multiplexed bypass control system for aerospace batteries

    NASA Technical Reports Server (NTRS)

    Frank, H. A.

    1977-01-01

    A breadboard bypass control system was developed to control a battery comprised of 26 JPL-developed negative limited Ni-Cd cells. The system was designed to automatically remove cells from the circuit when their voltages exceeded a fixed limit on charge and fell below a fixed limit on discharge. Major components of the system consisted of a cell voltage monitor, a multiplexing circuit, and individual electromechanical relays for each cell. The system was found to function well in controlling the battery during a simulated 10-month MM-71 mission and a 2-month simulated low earth orbit cycling mission. A flight version of the bypass system was estimated to have a total parts count of 150 and total weight of 1.63 kg. When fully developed, the system shows promise for improving life and reliability of spacecraft batteries.

  14. Evaluation of Urinary Tract Dilation Classification System for Grading Postnatal Hydronephrosis.

    PubMed

    Hodhod, Amr; Capolicchio, John-Paul; Jednak, Roman; El-Sherif, Eid; El-Doray, Abd El-Alim; El-Sherbiny, Mohamed

    2016-03-01

    We assessed the reliability and validity of the Urinary Tract Dilation classification system as a new grading system for postnatal hydronephrosis. We retrospectively reviewed charts of patients who presented with hydronephrosis from 2008 to 2013. We included patients diagnosed prenatally and those with hydronephrosis discovered incidentally during the first year of life. We excluded cases involving urinary tract infection, neurogenic bladder and chromosomal anomalies, those associated with extraurinary congenital malformations and those with followup of less than 24 months without resolution. Hydronephrosis was graded postnatally using the Society for Fetal Urology system, and then the management protocol was chosen. All units were regraded using the Urinary Tract Dilation classification system and compared to the Society for Fetal Urology system to assess reliability. Univariate and multivariate analyses were performed to assess the validity of the Urinary Tract Dilation classification system in predicting hydronephrosis resolution and surgical intervention. A total of 490 patients (730 renal units) were eligible to participate. The Urinary Tract Dilation classification system was reliable in the assessment of hydronephrosis (parallel forms 0.92). Hydronephrosis resolved in 357 units (49%), and 86 units (12%) were managed by surgical intervention. The remainder of renal units demonstrated stable or improved hydronephrosis. Multivariate analysis revealed that the likelihood of surgical intervention was predicted independently by Urinary Tract Dilation classification system risk group, while Society for Fetal Urology grades were predictive of likelihood of resolution. The Urinary Tract Dilation classification system is reliable for evaluation of postnatal hydronephrosis and is valid in predicting surgical intervention. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  15. Redesign of the System for Evaluation of Teaching Qualities in Anesthesiology Residency Training (SETQ Smart).

    PubMed

    Lombarts, Kiki M J M H; Ferguson, Andrew; Hollmann, Markus W; Malling, Bente; Arah, Onyebuchi A

    2016-11-01

    Given the increasing international recognition of clinical teaching as a competency and regulation of residency training, evaluation of anesthesiology faculty teaching is needed. The System for Evaluating Teaching Qualities (SETQ) Smart questionnaires were developed for assessing teaching performance of faculty in residency training programs in different countries. This study investigated (1) the structure, (2) the psychometric qualities of the new tools, and (3) the number of residents' evaluations needed per anesthesiology faculty to use the instruments reliably. Two SETQ Smart questionnaires-for faculty self-evaluation and for resident evaluation of faculty-were developed. A multicenter survey was conducted among 399 anesthesiology faculty and 430 residents in six countries. Statistical analyses included exploratory factor analysis, reliability analysis using Cronbach α, item-total scale correlations, interscale correlations, comparison of composite scales to global ratings, and generalizability analysis to assess residents' evaluations needed per faculty. In total, 240 residents completed 1,622 evaluations of 247 faculty. The SETQ Smart questionnaires revealed six teaching qualities consisting of 25 items. Cronbach α's were very high (greater than 0.95) for the overall SETQ Smart questionnaires and high (greater than 0.80) for the separate teaching qualities. Interscale correlations were all within the acceptable range of moderate correlation. Overall, questionnaire and scale scores correlated moderately to highly with the global ratings. For reliable feedback to individual faculty, three to five resident evaluations are needed. The first internationally piloted questionnaires for evaluating individual anesthesiology faculty teaching performance can be reliably, validly, and feasibly used for formative purposes in residency training.

  16. Study of turboprop systems reliability and maintenance costs

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The overall reliability and maintenance costs (R&MC's) of past and current turboprop systems were examined. Maintenance cost drivers were found to be scheduled overhaul (40%), lack of modularity particularly in the propeller and reduction gearbox, and lack of inherent durability (reliability) of some parts. Comparisons were made between the 501-D13/54H60 turboprop system and the widely used JT8D turbofan. It was found that the total maintenance cost per flight hour of the turboprop was 75% higher than that of the JT8D turbofan. Part of this difference was due to propeller and gearbox costs being higher than those of the fan and reverser, but most of the difference was in the engine core where the older technology turboprop core maintenance costs were nearly 70 percent higher than for the turbofan. The estimated maintenance cost of both the advanced turboprop and advanced turbofan were less than the JT8D. The conclusion was that an advanced turboprop and an advanced turbofan, using similar cores, will have very competitive maintenance costs per flight hour.

  17. The revised NEUROGES-ELAN system: An objective and reliable interdisciplinary analysis tool for nonverbal behavior and gesture.

    PubMed

    Lausberg, Hedda; Sloetjes, Han

    2016-09-01

    As visual media spread to all domains of public and scientific life, nonverbal behavior is taking its place as an important form of communication alongside the written and spoken word. An objective and reliable method of analysis for hand movement behavior and gesture is therefore currently required in various scientific disciplines, including psychology, medicine, linguistics, anthropology, sociology, and computer science. However, no adequate common methodological standards have been developed thus far. Many behavioral gesture-coding systems lack objectivity and reliability, and automated methods that register specific movement parameters often fail to show validity with regard to psychological and social functions. To address these deficits, we have combined two methods, an elaborated behavioral coding system and an annotation tool for video and audio data. The NEUROGES-ELAN system is an effective and user-friendly research tool for the analysis of hand movement behavior, including gesture, self-touch, shifts, and actions. Since its first publication in 2009 in Behavior Research Methods, the tool has been used in interdisciplinary research projects to analyze a total of 467 individuals from different cultures, including subjects with mental disease and brain damage. Partly on the basis of new insights from these studies, the system has been revised methodologically and conceptually. The article presents the revised version of the system, including a detailed study of reliability. The improved reproducibility of the revised version makes NEUROGES-ELAN a suitable system for basic empirical research into the relation between hand movement behavior and gesture and cognitive, emotional, and interactive processes and for the development of automated movement behavior recognition methods.

  18. Quantifying the Economic and Grid Reliability Impacts of Improved Wind Power Forecasting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Qin; Martinez-Anido, Carlo Brancucci; Wu, Hongyu

    Wind power forecasting is an important tool in power system operations to address variability and uncertainty. Accurately doing so is important to reducing the occurrence and length of curtailment, enhancing market efficiency, and improving the operational reliability of the bulk power system. This research quantifies the value of wind power forecasting improvements in the IEEE 118-bus test system as modified to emulate the generation mixes of Midcontinent, California, and New England independent system operator balancing authority areas. To measure the economic value, a commercially available production cost modeling tool was used to simulate the multi-timescale unit commitment (UC) and economicmore » dispatch process for calculating the cost savings and curtailment reductions. To measure the reliability improvements, an in-house tool, FESTIV, was used to calculate the system's area control error and the North American Electric Reliability Corporation Control Performance Standard 2. The approach allowed scientific reproducibility of results and cross-validation of the tools. A total of 270 scenarios were evaluated to accommodate the variation of three factors: generation mix, wind penetration level, and wind fore-casting improvements. The modified IEEE 118-bus systems utilized 1 year of data at multiple timescales, including the day-ahead UC, 4-hour-ahead UC, and 5-min real-time dispatch. The value of improved wind power forecasting was found to be strongly tied to the conventional generation mix, existence of energy storage devices, and the penetration level of wind energy. The simulation results demonstrate that wind power forecasting brings clear benefits to power system operations.« less

  19. Cross-cultural challenges for assessing medical professionalism among clerkship physicians in a Middle Eastern country (Bahrain): feasibility and psychometric properties of multisource feedback.

    PubMed

    Al Ansari, Ahmed; Al Khalifa, Khalid; Al Azzawi, Mohamed; Al Amer, Rashed; Al Sharqi, Dana; Al-Mansoor, Anwar; Munshi, Fadi M

    2015-01-01

    We aimed to design, implement, and evaluate the feasibility and reliability of a multisource feedback (MSF) system to assess interns in their clerkship year in the Middle Eastern culture, the Kingdom of Bahrain. The study was undertaken in the Bahrain Defense Force Hospital, a military teaching hospital in the Kingdom of Bahrain. A total of 21 interns (who represent the total population of the interns for the given year) were assessed in this study. All of the interns were rotating through our hospital during their year-long clerkship rotation. The study sample consisted of nine males and 12 females. Each participating intern was evaluated by three groups of raters, eight medical intern colleagues, eight senior medical colleagues, and eight coworkers from different departments. A total of 21 interns (nine males and 12 females) were assessed in this study. The total mean response rates were 62.3%. A factor analysis was conducted that found that the data on the questionnaire grouped into three factors that counted for 76.4% of the total variance. These three factors were labeled as professionalism, collaboration, and communication. Reliability analysis indicated that the full instrument scale had high internal consistency (Cronbach's α 0.98). The generalizability coefficients for the surveys were estimated to be 0.78. Based on our results and analysis, we conclude that the MSF tool we used on the interns rotating in their clerkship year within our Middle Eastern culture provides an effective method of evaluation because it offers a reliable, valid, and feasible process.

  20. Impact of Total Ionizing Dose Radiation Testing and Long-Term Thermal Cycling on the Operation of CMF20120D Silicon Carbide Power MOSFET

    NASA Technical Reports Server (NTRS)

    Patterson, Richard L.; Scheidegger, Robert J.; Lauenstein, Jean-Marie; Casey, Megan; Scheick, Leif; Hammoud, Ahmad

    2013-01-01

    Power systems designed for use in NASA space missions are required to work reliably under harsh conditions including radiation, thermal cycling, and extreme temperature exposures. Silicon carbide devices show great promise for use in future power electronics systems, but information pertaining to performance of the devices in the space environment is very scarce. A silicon carbide N-channel enhancement-mode power MOSFET called the CMF20120 is of interest for use in space environments. Samples of the device were exposed to radiation followed by long-term thermal cycling to address their reliability for use in space applications. The results of the experimental work are presentd and discussed.

  1. Flight Testing of the Capillary Pumped Loop 3 Experiment

    NASA Technical Reports Server (NTRS)

    Ottenstein, Laura; Butler, Dan; Ku, Jentung; Cheung, Kwok; Baldauff, Robert; Hoang, Triem

    2002-01-01

    The Capillary Pumped Loop 3 (CAPL 3) experiment was a multiple evaporator capillary pumped loop experiment that flew in the Space Shuttle payload bay in December 2001 (STS-108). The main objective of CAPL 3 was to demonstrate in micro-gravity a multiple evaporator capillary pumped loop system, capable of reliable start-up, reliable continuous operation, and heat load sharing, with hardware for a deployable radiator. Tests performed on orbit included start-ups, power cycles, low power tests (100 W total), high power tests (up to 1447 W total), heat load sharing, variable/fixed conductance transition tests, and saturation temperature change tests. The majority of the tests were completed successfully, although the experiment did exhibit an unexpected sensitivity to shuttle maneuvers. This paper describes the experiment, the tests performed during the mission, and the test results.

  2. "Reliability of the Norwegian version of the short physical performance battery in older people with and without dementia".

    PubMed

    Olsen, Cecilie Fromholt; Bergland, Astrid

    2017-06-09

    The purpose of the study was to establish the test-retest reliability of the Norwegian version of the Short Physical Performance Battery (SPPB). This was a cross- sectional reliability study. A convenience sample of 61 older adults with a mean age of 88.4(8.1) was tested by two different physiotherapists at two time points. The mean time interval between tests was 2.5 days. The Intraclass Correlation Coefficient model 3.1 (ICC, 3.1) with 95% confidence intervals as well as the weighted Kappa (K) were used as measures of relative reliability. The Standard Error of Measurement (SEM) and Minimal Detectable Change (MDC) were used to measure absolute reliability. The results were also analyzed for a subgroup of 24 older people with dementia. The ICC reflected high relative reliability for the SPPB summary score and the 4 m walk test (4mwt), both for the total sample (ICC = 0.92, and 0.91 respectively)) and for the subgroup with dementia (ICC = 0.84 and 0.90 respectively). Furthermore, weighted Ks for the SPPB subscales were 0.64 for the chair stand, 0.80 for gait and 0.52 for balance for the total sample and almost identical for the subgroup with dementia. MDC-values at the 95% confidence intervals (MDC95) were calculated at 0.8 for the total score of SPPB and 0.39 m/s for the 4mwt in the total sample. For the subgroup with dementia MDC95 was 1.88 for the total score of SPPB and 0.28 m/s for 4mwt. The SPPB total score and the timed walking test showed overall high relative and absolute reliability for the total sample indicating that the Norwegian version of the SPPB is reliable when used by trained physiotherapists with older people. The reliability of the Norwegian SPPB in older people with dementia seems high, but due to a small sample size this needs further investigation.

  3. Closed-form solution of decomposable stochastic models

    NASA Technical Reports Server (NTRS)

    Sjogren, Jon A.

    1990-01-01

    Markov and semi-Markov processes are increasingly being used in the modeling of complex reconfigurable systems (fault tolerant computers). The estimation of the reliability (or some measure of performance) of the system reduces to solving the process for its state probabilities. Such a model may exhibit numerous states and complicated transition distributions, contributing to an expensive and numerically delicate solution procedure. Thus, when a system exhibits a decomposition property, either structurally (autonomous subsystems), or behaviorally (component failure versus reconfiguration), it is desirable to exploit this decomposition in the reliability calculation. In interesting cases there can be failure states which arise from non-failure states of the subsystems. Equations are presented which allow the computation of failure probabilities of the total (combined) model without requiring a complete solution of the combined model. This material is presented within the context of closed-form functional representation of probabilities as utilized in the Symbolic Hierarchical Automated Reliability and Performance Evaluator (SHARPE) tool. The techniques adopted enable one to compute such probability functions for a much wider class of systems at a reduced computational cost. Several examples show how the method is used, especially in enhancing the versatility of the SHARPE tool.

  4. Reliability of Total Test Scores When Considered as Ordinal Measurements

    ERIC Educational Resources Information Center

    Biswas, Ajoy Kumar

    2006-01-01

    This article studies the ordinal reliability of (total) test scores. This study is based on a classical-type linear model of observed score (X), true score (T), and random error (E). Based on the idea of Kendall's tau-a coefficient, a measure of ordinal reliability for small-examinee populations is developed. This measure is extended to large…

  5. Experimental optimization of the FireFly 600 photovoltaic off-grid system.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyson, William Earl; Orozco, Ron; Ralph, Mark E.

    2003-10-01

    A comprehensive evaluation and experimental optimization of the FireFly{trademark} 600 off-grid photovoltaic system manufactured by Energia Total, Ltd. was conducted at Sandia National Laboratories in May and June of 2001. This evaluation was conducted at the request of the manufacturer and addressed performance of individual system components, overall system functionality and performance, safety concerns, and compliance with applicable codes and standards. A primary goal of the effort was to identify areas for improvement in performance, reliability, and safety. New system test procedures were developed during the effort.

  6. Reliability analysis of redundant systems. [a method to compute transition probabilities

    NASA Technical Reports Server (NTRS)

    Yeh, H. Y.

    1974-01-01

    A method is proposed to compute the transition probability (the probability of partial or total failure) of parallel redundant system. The effect of geometry of the system, the direction of load, and the degree of redundancy on the probability of complete survival of parachute-like system are also studied. The results show that the probability of complete survival of three-member parachute-like system is very sensitive to the variation of horizontal angle of the load. However, it becomes very insignificant as the degree of redundancy increases.

  7. Reliability and cost evaluation of small isolated power systems containing photovoltaic and wind energy

    NASA Astrophysics Data System (ADS)

    Karki, Rajesh

    Renewable energy application in electric power systems is growing rapidly worldwide due to enhanced public concerns for adverse environmental impacts and escalation in energy costs associated with the use of conventional energy sources. Photovoltaics and wind energy sources are being increasingly recognized as cost effective generation sources. A comprehensive evaluation of reliability and cost is required to analyze the actual benefits of utilizing these energy sources. The reliability aspects of utilizing renewable energy sources have largely been ignored in the past due the relatively insignificant contribution of these sources in major power systems, and consequently due to the lack of appropriate techniques. Renewable energy sources have the potential to play a significant role in the electrical energy requirements of small isolated power systems which are primarily supplied by costly diesel fuel. A relatively high renewable energy penetration can significantly reduce the system fuel costs but can also have considerable impact on the system reliability. Small isolated systems routinely plan their generating facilities using deterministic adequacy methods that cannot incorporate the highly erratic behavior of renewable energy sources. The utilization of a single probabilistic risk index has not been generally accepted in small isolated system evaluation despite its utilization in most large power utilities. Deterministic and probabilistic techniques are combined in this thesis using a system well-being approach to provide useful adequacy indices for small isolated systems that include renewable energy. This thesis presents an evaluation model for small isolated systems containing renewable energy sources by integrating simulation models that generate appropriate atmospheric data, evaluate chronological renewable power outputs and combine total available energy and load to provide useful system indices. A software tool SIPSREL+ has been developed which generates risk, well-being and energy based indices to provide realistic cost/reliability measures of utilizing renewable energy. The concepts presented and the examples illustrated in this thesis will help system planners to decide on appropriate installation sites, the types and mix of different energy generating sources, the optimum operating policies, and the optimum generation expansion plans required to meet increasing load demands in small isolated power systems containing photovoltaic and wind energy sources.

  8. Intra-operative reliability of ShapeMatch cutting guide placement in total knee arthroplasty.

    PubMed

    Clark, Gavin; Leong, Anthony; McEwen, Peter; Steele, Robert; Tran, Ton; Trivett, Adrian

    2013-01-01

    Custom cutting guides based on pre-operative imaging have been introduced for total knee arthroplasty (TKA). The aim of this prospective cohort study was to assess the reliability of repeated placement of custom cutting guides by multiple surgeons in a group of patients undergoing TKA. Custom cutting guides (ShapeMatch®, Stryker Orthopaedics) were designed from pre-operative MRI scans. The treating surgeon placed each guide on the femur and tibia of each patient three times without pinning the block. The three-dimensional position and orientation of the guide was measured for each repetition using a computer navigation system. The surgeon was blinded to the navigation system display. Data from 24 patients and 6 surgeons were analyzed. Intraclass correlation coefficients for all measurement parameters were in the range 0.889-0.997 (excellent), and all comparisons were statistically significant (p < 0.001). The range for femoral varus/valgus was 0.0-1.5°, with 96% of patients being within 0.5°. For femoral flexion/extension the range was 0.0-3.5° (92% within 2.5°). On the tibia, varus/valgus had a range of 0.0-1.0° (92% within 0.5°), and for slope the range was 0.0-3.5° (92% within 2.5°). The high degree of agreement indicated that intra-surgeon variation was minimal and that the technique is reliable.

  9. Analytical Assessment of the Reciprocating Feed System

    NASA Technical Reports Server (NTRS)

    Eddleman, David E.; Blackmon, James B.; Morton, Christopher D.

    2006-01-01

    A preliminary analysis tool has been created in Microsoft Excel to determine deliverable payload mass, total system mass, and performance of spacecraft systems using various types of propellant feed systems. These mass estimates are conducted by inserting into the user interface the basic mission parameters (e.g., thrust, burn time, specific impulse, mixture ratio, etc.), system architecture (e.g., propulsion system type and characteristics, propellants, pressurization system type, etc.), and design properties (e.g., material properties, safety factors, etc.). Different propellant feed and pressurization systems are available for comparison in the program. This gives the user the ability to compare conventional pressure fed, reciprocating feed system (RFS), autogenous pressurization thrust augmentation (APTA RFS), and turbopump systems with the deliverable payload, inert mass, and total system mass being the primary comparison metrics. Analyses of several types of missions and spacecraft were conducted and it was found that the RFS offers a performance improvement, especially in terms of delivered payload, over conventional pressure fed systems. Furthermore, it is competitive with a turbopump system at low to moderate chamber pressures, up to approximately 1,500 psi. Various example cases estimating the system mass and deliverable payload of several types of spacecraft are presented that illustrate the potential system performance advantages of the RFS. In addition, a reliability assessment of the RFS was conducted, comparing it to simplified conventional pressure fed and turbopump systems, based on MIL-STD 756B; these results showed that the RFS offers higher reliability, and thus substantially longer periods between system refurbishment, than turbopump systems, and is competitive with conventional pressure fed systems. This is primarily the result of the intrinsic RFS fail-operational capability with three run tanks, since the system can operate with just two run tanks.

  10. Reliability and Generalizability of Ratings of Compositions.

    ERIC Educational Resources Information Center

    Lehmann, Rainer H.

    A total of 1,487 eleventh grade students from the Hamburg (West Germany) school system were asked to complete four writing assignments used in an International Association for the Evaluation of Educational Achievement (IEA) study of writing assessment. In analyzing the writing samples, the study focused on: (1) between-rater effects; (2)…

  11. Reliability and Productivity Modeling for the Optimization of Separated Spacecraft Interferometers

    NASA Technical Reports Server (NTRS)

    Kenny, Sean (Technical Monitor); Wertz, Julie

    2002-01-01

    As technological systems grow in capability, they also grow in complexity. Due to this complexity, it is no longer possible for a designer to use engineering judgement to identify the components that have the largest impact on system life cycle metrics, such as reliability, productivity, cost, and cost effectiveness. One way of identifying these key components is to build quantitative models and analysis tools that can be used to aid the designer in making high level architecture decisions. Once these key components have been identified, two main approaches to improving a system using these components exist: add redundancy or improve the reliability of the component. In reality, the most effective approach to almost any system will be some combination of these two approaches, in varying orders of magnitude for each component. Therefore, this research tries to answer the question of how to divide funds, between adding redundancy and improving the reliability of components, to most cost effectively improve the life cycle metrics of a system. While this question is relevant to any complex system, this research focuses on one type of system in particular: Separate Spacecraft Interferometers (SSI). Quantitative models are developed to analyze the key life cycle metrics of different SSI system architectures. Next, tools are developed to compare a given set of architectures in terms of total performance, by coupling different life cycle metrics together into one performance metric. Optimization tools, such as simulated annealing and genetic algorithms, are then used to search the entire design space to find the "optimal" architecture design. Sensitivity analysis tools have been developed to determine how sensitive the results of these analyses are to uncertain user defined parameters. Finally, several possibilities for the future work that could be done in this area of research are presented.

  12. INFLUENCES OF RESPONSE RATE AND DISTRIBUTION ON THE CALCULATION OF INTEROBSERVER RELIABILITY SCORES

    PubMed Central

    Rolider, Natalie U.; Iwata, Brian A.; Bullock, Christopher E.

    2012-01-01

    We examined the effects of several variations in response rate on the calculation of total, interval, exact-agreement, and proportional reliability indices. Trained observers recorded computer-generated data that appeared on a computer screen. In Study 1, target responses occurred at low, moderate, and high rates during separate sessions so that reliability results based on the four calculations could be compared across a range of values. Total reliability was uniformly high, interval reliability was spuriously high for high-rate responding, proportional reliability was somewhat lower for high-rate responding, and exact-agreement reliability was the lowest of the measures, especially for high-rate responding. In Study 2, we examined the separate effects of response rate per se, bursting, and end-of-interval responding. Response rate and bursting had little effect on reliability scores; however, the distribution of some responses at the end of intervals decreased interval reliability somewhat, proportional reliability noticeably, and exact-agreement reliability markedly. PMID:23322930

  13. Launch vehicle systems design analysis

    NASA Technical Reports Server (NTRS)

    Ryan, Robert; Verderaime, V.

    1993-01-01

    Current launch vehicle design emphasis is on low life-cycle cost. This paper applies total quality management (TQM) principles to a conventional systems design analysis process to provide low-cost, high-reliability designs. Suggested TQM techniques include Steward's systems information flow matrix method, quality leverage principle, quality through robustness and function deployment, Pareto's principle, Pugh's selection and enhancement criteria, and other design process procedures. TQM quality performance at least-cost can be realized through competent concurrent engineering teams and brilliance of their technical leadership.

  14. Reliability Estimation When a Test Is Split into Two Parts of Unknown Effective Length.

    ERIC Educational Resources Information Center

    Feldt, Leonard S.

    2002-01-01

    Considers the situation in which content or administrative considerations limit the way in which a test can be partitioned to estimate the internal consistency reliability of the total test score. Demonstrates that a single-valued estimate of the total score reliability is possible only if an assumption is made about the comparative size of the…

  15. Development of a microcontroller-based automatic control system for the electrohydraulic total artificial heart.

    PubMed

    Kim, H C; Khanwilkar, P S; Bearnson, G B; Olsen, D B

    1997-01-01

    An automatic physiological control system for the actively filled, alternately pumped ventricles of the volumetrically coupled, electrohydraulic total artificial heart (EHTAH) was developed for long-term use. The automatic control system must ensure that the device: 1) maintains a physiological response of cardiac output, 2) compensates for an nonphysiological condition, and 3) is stable, reliable, and operates at a high power efficiency. The developed automatic control system met these requirements both in vitro, in week-long continuous mock circulation tests, and in vivo, in acute open-chested animals (calves). Satisfactory results were also obtained in a series of chronic animal experiments, including 21 days of continuous operation of the fully automatic control mode, and 138 days of operation in a manual mode, in a 159-day calf implant.

  16. French adaptation of the new Knee Society Scoring System for total knee arthroplasty.

    PubMed

    Debette, C; Parratte, S; Maucort-Boulch, D; Blanc, G; Pauly, V; Lustig, S; Servien, E; Neyret, P; Argenson, J N

    2014-09-01

    In November 2011, the Knee Society published its new KSS score to evaluate objective clinical data and also patient expectations, satisfaction and knee function during various physical activities before and after total knee arthroplasty (TKA). We undertook the French cross-cultural adaptation of this scoring system according to current recommendations. The French version of the new KSS score is a consistent, feasible, reliable and discriminating score. Eighty patients with knee osteoarthritis were recruited from two centers: one group of 40 patients had a TKA indication, while the other group of 40 patients had an indication for conservative treatment. After the new KSS score was translated and back-translated, it was compared to three other validated instruments (KOOS, AMIQUAL and SF-12) to determine construct validity, discriminating power, feasibility in terms of response rate and existence of floor or ceiling effect, internal consistency with Chronbach's alpha and reliability based on reproducibility and sensitivity to change (responsiveness). Due to missing data, two cases were eliminated. We found that the score could discriminate between groups; it had a nearly 100% response rate, a ceiling effect in the "expectations" domain, satisfactory Chronbach's alpha, excellent reproducibility and good responsiveness. These results confirm that the French version of the new KSS score is reliable, feasible, discriminating, consistent and responsive. The novelty of this scoring system resides in the "expectations" and "satisfaction" domains, its availability as a self-assessment questionnaire and the evaluation of function during various activities. Level III. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  17. Reliability of the Melbourne assessment of unilateral upper limb function.

    PubMed

    Randall, M; Carlin, J B; Chondros, P; Reddihough, D

    2001-11-01

    This study examines the reliability of the Melbourne Assessment of Unilateral Upper Limb Function: a quantitative test of quality of movement in children with neurological impairment. The assessment was administered to 20 children aged from 5 to 16 years (mean age 9 years 10 months, SD 2 years 10 months) who had various types and degrees of cerebral palsy (CP). The performances of the 20 children during assessment were videotaped for subsequent scoring by 15 occupational therapists. Scores were analyzed for internal consistency of test items, inter- and intrarater reliability of scorings of the same videotapes, and test-retest reliability using repeat videotaping. Results revealed very high internal consistency of test items (alpha=0.96), moderate to high agreement both within and between raters for all test items (intraclass correlations of at least 0.7) apart from item 16 (hand to mouth and down), and high interrater reliability (0.95) and intrarater reliability (0.97) for total test scores. Test-retest results revealed moderate to high intrarater reliability for item totals (mean of 0.83 and 0.79) for each rater and high reliability for test totals (0.98 and 0.97). These findings indicate that the Melbourne Assessment of Unilateral Upper Limb Function is a reliable tool for measuring the quality of unilateral upper-limb movement in children with CP.

  18. Reliability of a novel, semi-quantitative scale for classification of structural brain magnetic resonance imaging in children with cerebral palsy.

    PubMed

    Fiori, Simona; Cioni, Giovanni; Klingels, Katrjin; Ortibus, Els; Van Gestel, Leen; Rose, Stephen; Boyd, Roslyn N; Feys, Hilde; Guzzetta, Andrea

    2014-09-01

    To describe the development of a novel rating scale for classification of brain structural magnetic resonance imaging (MRI) in children with cerebral palsy (CP) and to assess its interrater and intrarater reliability. The scale consists of three sections. Section 1 contains descriptive information about the patient and MRI. Section 2 contains the graphical template of brain hemispheres onto which the lesion is transposed. Section 3 contains the scoring system for the quantitative analysis of the lesion characteristics, grouped into different global scores and subscores that assess separately side, regions, and depth. A larger interrater and intrarater reliability study was performed in 34 children with CP (22 males, 12 females; mean age at scan of 9 y 5 mo [SD 3 y 3 mo], range 4 y-16 y 11 mo; Gross Motor Function Classification System level I, [n=22], II [n=10], and level III [n=2]). Very high interrater and intrarater reliability of the total score was found with indices above 0.87. Reliability coefficients of the lobar and hemispheric subscores ranged between 0.53 and 0.95. Global scores for hemispheres, basal ganglia, brain stem, and corpus callosum showed reliability coefficients above 0.65. This study presents the first visual, semi-quantitative scale for classification of brain structural MRI in children with CP. The high degree of reliability of the scale supports its potential application for investigating the relationship between brain structure and function and examining treatment response according to brain lesion severity in children with CP. © 2014 Mac Keith Press.

  19. Measuring eating disorder attitudes and behaviors: a reliability generalization study

    PubMed Central

    2014-01-01

    Background Although score reliability is a sample-dependent characteristic, researchers often only report reliability estimates from previous studies as justification for employing particular questionnaires in their research. The present study followed reliability generalization procedures to determine the mean score reliability of the Eating Disorder Inventory and its most commonly employed subscales (Drive for Thinness, Bulimia, and Body Dissatisfaction) and the Eating Attitudes Test as a way to better identify those characteristics that might impact score reliability. Methods Published studies that used these measures were coded based on their reporting of reliability information and additional study characteristics that might influence score reliability. Results Score reliability estimates were included in 26.15% of studies using the EDI and 36.28% of studies using the EAT. Mean Cronbach’s alphas for the EDI (total score = .91; subscales = .75 to .89), EAT-40 (total score = .81) and EAT-26 (total score = .86; subscales = .56 to .80) suggested variability in estimated internal consistency. Whereas some EDI subscales exhibited higher score reliability in clinical eating disorder samples than in nonclinical samples, other subscales did not exhibit these differences. Score reliability information for the EAT was primarily reported for nonclinical samples, making it difficult to characterize the effect of type of sample on these measures. However, there was a tendency for mean score reliability to be higher in the adult (vs. adolescent) samples and in female (vs. male) samples. Conclusions Overall, this study highlights the importance of assessing and reporting internal consistency during every test administration because reliability is affected by characteristics of the participants being examined. PMID:24764530

  20. The role of criteria in design and management of space systems

    NASA Technical Reports Server (NTRS)

    Blair, J. C.; Ryan, R. S.

    1992-01-01

    Explicit requirements and standards arising in connection with space systems management serve as a framework for technical management and furnish legally binding control of development, verification, and operations. As a project develops, additional requirements are derived which are unique to the system in question; these are designated 'derived requirements'. The reliability and cost-effectiveness of a space system are best ensured where a balance has arisen between formal (legally binding) and informal. Attention is presently given to the development of criteria consistent with total quality management.

  1. Optimal reconfiguration strategy for a degradable multimodule computing system

    NASA Technical Reports Server (NTRS)

    Lee, Yann-Hang; Shin, Kang G.

    1987-01-01

    The present quantitative approach to the problem of reconfiguring a degradable multimode system assigns some modules to computation and arranges others for reliability. By using expected total reward as the optimal criterion, there emerges an active reconfiguration strategy based not only on the occurrence of failure but the progression of the given mission. This reconfiguration strategy requires specification of the times at which the system should undergo reconfiguration, and the configurations to which the system should change. The optimal reconfiguration problem is converted to integer nonlinear knapsack and fractional programming problems.

  2. Can we have an overall osteoarthritis severity score for the patellofemoral joint using magnetic resonance imaging? Reliability and validity.

    PubMed

    Kobayashi, Sarah; Peduto, Anthony; Simic, Milena; Fransen, Marlene; Refshauge, Kathryn; Mah, Jean; Pappas, Evangelos

    2018-04-01

    This work aimed to assess inter-rater reliability and agreement of a magnetic resonance imaging (MRI)-based Kellgren and Lawrence (K&L) grading for patellofemoral joint osteoarthritis (OA) and to validate it against the MRI Osteoarthritis Knee Score (MOAKS). MRI scans from people aged 45 to 75 years with chronic knee pain participating in a randomised clinical trial evaluating dietary supplements were utilised. Fifty participants were randomly selected and scored using the MRI-based K&L grading using axial and sagittal MRI scans. Raters conducted inter-rater reliability, blinded to clinical information, radiology reports and other rater results. Intra- and inter-rater reliability and agreement were evaluated using the intra-class correlation coefficient (ICC) and Cohen's weighted kappa. There was a 2-week interval between the first and second readings for intra-rater reliability. Validity was assessed using the MOAKS and evaluated using Spearman's correlation coefficient. Intra-rater reliability of the K&L system was excellent: ICC 0.91 (95% CI 0.82-0.95); weighted kappa (ĸ = 0.69). Inter-rater reliability was high (ICC 0.88; 95% CI 0.79-0.93), while agreement between raters was moderate (ĸ = 0.49-0.57). Validity analysis demonstrated a strong correlation between the total MOAKS features score and the K&L grading system (ρ = 0.62-0.67) but weak correlations when compared with individual MOAKS features (ρ = 0.19-0.61). The high reliability and good agreement show consistency in grading the severity of patellofemoral OA with the MRI-based K&L score. Our validity results suggest that the scale may be useful, particularly in the clinical environment. Future research should validate this method against clinical findings.

  3. Reliability analysis based on the losses from failures.

    PubMed

    Todinov, M T

    2006-04-01

    The conventional reliability analysis is based on the premise that increasing the reliability of a system will decrease the losses from failures. On the basis of counterexamples, it is demonstrated that this is valid only if all failures are associated with the same losses. In case of failures associated with different losses, a system with larger reliability is not necessarily characterized by smaller losses from failures. Consequently, a theoretical framework and models are proposed for a reliability analysis, linking reliability and the losses from failures. Equations related to the distributions of the potential losses from failure have been derived. It is argued that the classical risk equation only estimates the average value of the potential losses from failure and does not provide insight into the variability associated with the potential losses. Equations have also been derived for determining the potential and the expected losses from failures for nonrepairable and repairable systems with components arranged in series, with arbitrary life distributions. The equations are also valid for systems/components with multiple mutually exclusive failure modes. The expected losses given failure is a linear combination of the expected losses from failure associated with the separate failure modes scaled by the conditional probabilities with which the failure modes initiate failure. On this basis, an efficient method for simplifying complex reliability block diagrams has been developed. Branches of components arranged in series whose failures are mutually exclusive can be reduced to single components with equivalent hazard rate, downtime, and expected costs associated with intervention and repair. A model for estimating the expected losses from early-life failures has also been developed. For a specified time interval, the expected losses from early-life failures are a sum of the products of the expected number of failures in the specified time intervals covering the early-life failures region and the expected losses given failure characterizing the corresponding time intervals. For complex systems whose components are not logically arranged in series, discrete simulation algorithms and software have been created for determining the losses from failures in terms of expected lost production time, cost of intervention, and cost of replacement. Different system topologies are assessed to determine the effect of modifications of the system topology on the expected losses from failures. It is argued that the reliability allocation in a production system should be done to maximize the profit/value associated with the system. Consequently, a method for setting reliability requirements and reliability allocation maximizing the profit by minimizing the total cost has been developed. Reliability allocation that maximizes the profit in case of a system consisting of blocks arranged in series is achieved by determining for each block individually the reliabilities of the components in the block that minimize the sum of the capital, operation costs, and the expected losses from failures. A Monte Carlo simulation based net present value (NPV) cash-flow model has also been proposed, which has significant advantages to cash-flow models based on the expected value of the losses from failures per time interval. Unlike these models, the proposed model has the capability to reveal the variation of the NPV due to different number of failures occurring during a specified time interval (e.g., during one year). The model also permits tracking the impact of the distribution pattern of failure occurrences and the time dependence of the losses from failures.

  4. Observer reliability of the Gross Motor Performance Measure and the Quality of Upper Extremity Skills Test, based on video recordings.

    PubMed

    Sorsdahl, Anne Brit; Moe-Nilssen, Rolf; Strand, Liv Inger

    2008-02-01

    The aim of this study was to examine observer reliability of the Gross Motor Performance Measure (GMPM) and the Quality of Upper Extremity Skills Test (QUEST) based on video clips. The tests were administered to 26 children with cerebral palsy (CP; 14 males, 12 females; range 2-13y, mean 7y 6mo), 24 with spastic CP, and two with dyskinesia. Respectively, five, six, five, four, and six children were classified in Gross Motor Function Classification System Levels I to V; and four, nine, five, five, and three children were classified in Manual Ability Classification System levels I to V. The children's performances were recorded and edited. Two experienced paediatric physical therapists assessed the children from watching the video clips. Intraobserver and interobserver reliability values of the total scores were mostly high, intraclass correlation coefficient (ICC)(1,1) varying from 0.69 to 0.97 with only one coefficient below 0.89. The ICCs of subscores varied from 0.36 to 0.95, finding'Alignment'and'Weight shift'in GMPM and'Protective extension'in QUEST highly reliable. The subscores'Dissociated movements'in GMPM and QUEST, and'Grasp'in QUEST were the least reliable, and recommendations are made to increase reliability of these subscores. Video scoring was time consuming, but was found to offer many advantages; the possibility to review performance, to use special trained observers for scoring and less demanding assessment for the children.

  5. A Discussion of Two Challenges of Non-cooperative Satellite Refueling

    NASA Technical Reports Server (NTRS)

    Coll, Gregory C.; Aranyos, Thomas; Nufer, Brian M.; Kandula, Max; Tomasic, David J.

    2015-01-01

    There is interest from government and commercial aerospace communities in advancing propellant transfer technology for in-orbit refueling of satellites. This paper introduces two challenges to a Propellant Transfer System (PTS) under development for demonstration of non-cooperative satellite refueling. The PTS is being developed to transfer storable propellant (heritage hypergolic fuels and oxidizers as well as xenon) safely and reliably from one servicer satellite to a non-cooperative typical existing client satellite. NASA is in the project evaluation planning stages for conducting a first time on-orbit demonstration to an existing government asset. The system manages pressure, flow rate totalization, temperature and other parameters to control the condition of the propellant being transferred to the client. It keeps the propellant isolated while performing leak checks of itself and the client interface before transferring propellant. A major challenge is to design a safe, reliable system with some new technologies while maintaining a reasonable cost.

  6. Face Liveness Detection Using Defocus

    PubMed Central

    Kim, Sooyeon; Ban, Yuseok; Lee, Sangyoun

    2015-01-01

    In order to develop security systems for identity authentication, face recognition (FR) technology has been applied. One of the main problems of applying FR technology is that the systems are especially vulnerable to attacks with spoofing faces (e.g., 2D pictures). To defend from these attacks and to enhance the reliability of FR systems, many anti-spoofing approaches have been recently developed. In this paper, we propose a method for face liveness detection using the effect of defocus. From two images sequentially taken at different focuses, three features, focus, power histogram and gradient location and orientation histogram (GLOH), are extracted. Afterwards, we detect forged faces through the feature-level fusion approach. For reliable performance verification, we develop two databases with a handheld digital camera and a webcam. The proposed method achieves a 3.29% half total error rate (HTER) at a given depth of field (DoF) and can be extended to camera-equipped devices, like smartphones. PMID:25594594

  7. A Discussion of Two Challenges of Non-Cooperative Satellite Refueling

    NASA Technical Reports Server (NTRS)

    Coll, Gregory T.; Aranyos, Thomas J.; Nufer, Brian M.; Tomasic, David; Kandula, Max

    2015-01-01

    There is interest from government and commercial aerospace communities in advancing propellant transfer technology for in-orbit refueling of satellites. This paper introduces two challenges to a Propellant Transfer System (PTS) under development for demonstration of non-cooperative satellite refueling. The PTS is being developed to transfer storable propellant (heritage hypergolic fuels and oxidizers as well as xenon) safely and reliably from one servicer satellite to a non-cooperative typical existing client satellite. NASA is in the project evaluation planning stages for conducting a first time on-orbit demonstration to an existing government asset. The system manages pressure, flow rate totalization, temperature and other parameters to control the condition of the propellant being transferred to the client. It keeps the propellant isolated while performing leak checks of itself and the client interface before transferring propellant. A major challenge is to design a safe, reliable system with some new technologies while maintaining a reasonable cost.

  8. Validation of the Social Appearance Anxiety Scale in Patients with Systemic Sclerosis: A Scleroderma Patient-centered Intervention Network Cohort Study.

    PubMed

    Mills, Sarah D; Kwakkenbos, Linda; Carrier, Marie-Eve; Gholizadeh, Shadi; Fox, Rina S; Jewett, Lisa R; Gottesman, Karen; Roesch, Scott C; Thombs, Brett D; Malcarne, Vanessa L

    2018-01-17

    Systemic sclerosis (SSc) is an autoimmune disease that can cause disfiguring changes in appearance. This study examined the structural validity, internal consistency reliability, convergent validity, and measurement equivalence of the Social Appearance Anxiety Scale (SAAS) across SSc disease subtypes. Patients enrolled in the Scleroderma Patient-centered Intervention Network Cohort completed the SAAS and measures of appearance-related concerns and psychological distress. Confirmatory factor analysis (CFA) was used to examine the structural validity of the SAAS. Multiple-group CFA was used to determine if SAAS scores can be compared across patients with limited and diffuse disease subtypes. Cronbach's alpha was used to examine internal consistency reliability. Correlations of SAAS scores with measures of body image dissatisfaction, fear of negative evaluation, social anxiety, and depression were used to examine convergent validity. SAAS scores were hypothesized to be positively associated with all convergent validity measures, with correlations significant and moderate to large in size. A total of 938 patients with SSc were included. CFA supported a one-factor structure (CFI: .92; SRMR: .04; RMSEA: .08), and multiple-group CFA indicated that the scalar invariance model best fit the data. Internal consistency reliability was good in the total sample (α = .96) and in disease subgroups. Overall, evidence of convergent validity was found with measures of body image dissatisfaction, fear of negative evaluation, social anxiety, and depression. The SAAS can be reliably and validly used to assess fear of appearance evaluation in patients with SSc, and SAAS scores can be meaningfully compared across disease subtypes. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  9. Cross-cultural challenges for assessing medical professionalism among clerkship physicians in a Middle Eastern country (Bahrain): feasibility and psychometric properties of multisource feedback

    PubMed Central

    Al Ansari, Ahmed; Al Khalifa, Khalid; Al Azzawi, Mohamed; Al Amer, Rashed; Al Sharqi, Dana; Al-Mansoor, Anwar; Munshi, Fadi M

    2015-01-01

    Background We aimed to design, implement, and evaluate the feasibility and reliability of a multisource feedback (MSF) system to assess interns in their clerkship year in the Middle Eastern culture, the Kingdom of Bahrain. Method The study was undertaken in the Bahrain Defense Force Hospital, a military teaching hospital in the Kingdom of Bahrain. A total of 21 interns (who represent the total population of the interns for the given year) were assessed in this study. All of the interns were rotating through our hospital during their year-long clerkship rotation. The study sample consisted of nine males and 12 females. Each participating intern was evaluated by three groups of raters, eight medical intern colleagues, eight senior medical colleagues, and eight coworkers from different departments. Results A total of 21 interns (nine males and 12 females) were assessed in this study. The total mean response rates were 62.3%. A factor analysis was conducted that found that the data on the questionnaire grouped into three factors that counted for 76.4% of the total variance. These three factors were labeled as professionalism, collaboration, and communication. Reliability analysis indicated that the full instrument scale had high internal consistency (Cronbach’s α 0.98). The generalizability coefficients for the surveys were estimated to be 0.78. Conclusion Based on our results and analysis, we conclude that the MSF tool we used on the interns rotating in their clerkship year within our Middle Eastern culture provides an effective method of evaluation because it offers a reliable, valid, and feasible process. PMID:26316836

  10. ETARA - EVENT TIME AVAILABILITY, RELIABILITY ANALYSIS

    NASA Technical Reports Server (NTRS)

    Viterna, L. A.

    1994-01-01

    The ETARA system was written to evaluate the performance of the Space Station Freedom Electrical Power System, but the methodology and software can be modified to simulate any system that can be represented by a block diagram. ETARA is an interactive, menu-driven reliability, availability, and maintainability (RAM) simulation program. Given a Reliability Block Diagram representation of a system, the program simulates the behavior of the system over a specified period of time using Monte Carlo methods to generate block failure and repair times as a function of exponential and/or Weibull distributions. ETARA can calculate availability parameters such as equivalent availability, state availability (percentage of time at a particular output state capability), continuous state duration and number of state occurrences. The program can simulate initial spares allotment and spares replenishment for a resupply cycle. The number of block failures are tabulated both individually and by block type. ETARA also records total downtime, repair time, and time waiting for spares. Maintenance man-hours per year and system reliability, with or without repair, at or above a particular output capability can also be calculated. The key to using ETARA is the development of a reliability or availability block diagram. The block diagram is a logical graphical illustration depicting the block configuration necessary for a function to be successfully accomplished. Each block can represent a component, a subsystem, or a system. The function attributed to each block is considered for modeling purposes to be either available or unavailable; there are no degraded modes of block performance. A block does not have to represent physically connected hardware in the actual system to be connected in the block diagram. The block needs only to have a role in contributing to an available system function. ETARA can model the RAM characteristics of systems represented by multilayered, nesting block diagrams. There are no restrictions on the number of total blocks or on the number of blocks in a series, parallel, or M-of-N parallel subsystem. In addition, the same block can appear in more than one subsystem if such an arrangement is necessary for an accurate model. ETARA 3.3 is written in APL2 for IBM PC series computers or compatibles running MS-DOS and the APL2 interpreter. Hardware requirements for the APL2 system include 640K of RAM, 2Mb of extended memory, and an 80386 or 80486 processor with an 80x87 math co-processor. The standard distribution medium for this package is a set of two 5.25 inch 360K MS-DOS format diskettes. A sample executable is included. The executable contains licensed material from the APL2 for the IBM PC product which is program property of IBM; Copyright IBM Corporation 1988 - All rights reserved. It is distributed with IBM's permission. The contents of the diskettes are compressed using the PKWARE archiving tools. The utility to unarchive the files, PKUNZIP.EXE, is included. ETARA was developed in 1990 and last updated in 1991.

  11. Disease Severity and Progression in Progressive Supranuclear Palsy and Multiple System Atrophy: Validation of the NNIPPS – PARKINSON PLUS SCALE

    PubMed Central

    Payan, Christine A. M.; Viallet, François; Landwehrmeyer, Bernhard G.; Bonnet, Anne-Marie; Borg, Michel; Durif, Franck; Lacomblez, Lucette; Bloch, Frédéric; Verny, Marc; Fermanian, Jacques; Agid, Yves; Ludolph, Albert C.

    2011-01-01

    Background The Natural History and Neuroprotection in Parkinson Plus Syndromes (NNIPPS) study was a large phase III randomized placebo-controlled trial of riluzole in Progressive Supranuclear Palsy (PSP, n = 362) and Multiple System Atrophy (MSA, n = 398). To assess disease severity and progression, we constructed and validated a new clinical rating scale as an ancillary study. Methods and Findings Patients were assessed at entry and 6-montly for up to 3 years. Evaluation of the scale's psychometric properties included reliability (n = 116), validity (n = 760), and responsiveness (n = 642). Among the 85 items of the initial scale, factor analysis revealed 83 items contributing to 15 clinically relevant dimensions, including Activity of daily Living/Mobility, Axial bradykinesia, Limb bradykinesia, Rigidity, Oculomotor, Cerebellar, Bulbar/Pseudo-bulbar, Mental, Orthostatic, Urinary, Limb dystonia, Axial dystonia, Pyramidal, Myoclonus and Tremor. All but the Pyramidal dimension demonstrated good internal consistency (Cronbach α≥0.70). Inter-rater reliability was high for the total score (Intra-class coefficient = 0.94) and 9 dimensions (Intra-class coefficient = 0.80–0.93), and moderate (Intra-class coefficient = 0.54–0.77) for 6. Correlations of the total score with other clinical measures of severity were good (rho≥0.70). The total score was significantly and linearly related to survival (p<0.0001). Responsiveness expressed as the Standardized Response Mean was high for the total score slope of change (SRM = 1.10), though higher in PSP (SRM = 1.25) than in MSA (SRM = 1.0), indicating a more rapid progression of PSP. The slope of change was constant with increasing disease severity demonstrating good linearity of the scale throughout disease stages. Although MSA and PSP differed quantitatively on the total score at entry and on rate of progression, the relative contribution of clinical dimensions to overall severity and progression was similar. Conclusions The NNIPPS-PPS has suitable validity, is reliable and sensitive, and therefore is appropriate for use in clinical studies with PSP or MSA. Trial Registration ClinicalTrials.gov NCT00211224 PMID:21829612

  12. Writing Evaluation: Rater and Task Effects on the Reliability of Writing Scores for Children in Grades 3 and 4

    PubMed Central

    Kim, Grace Young-Suk; Schatschneider, Christopher; Wanzek, Jeanne; Gatlin, Brandy; Al Otaiba, Stephanie

    2017-01-01

    We examined how raters and tasks influence measurement error in writing evaluation and how many raters and tasks are needed to reach a desirable level of .90 and .80 reliabilities for children in Grades 3 and 4. A total of 211 children (102 boys) were administered three tasks in narrative and expository genres, respectively, and their written compositions were evaluated in widely used evaluation methods for developing writers: holistic scoring, productivity, and curriculum-based writing scores. Results showed that 54% and 52% of variance in narrative and expository compositions were attributable to true individual differences in writing. Students’ scores varied largely by tasks (30.44% and 28.61% of variance), but not by raters. To reach the reliability of .90, multiple tasks and raters were needed, and for the reliability of .80, a single rater and multiple tasks were needed. These findings offer important implications about reliably evaluating children’s writing skills, given that writing is typically evaluated by a single task and a single rater in classrooms and even in state accountability systems. PMID:29075050

  13. Scheduling structural health monitoring activities for optimizing life-cycle costs and reliability of wind turbines

    NASA Astrophysics Data System (ADS)

    Hanish Nithin, Anu; Omenzetter, Piotr

    2017-04-01

    Optimization of the life-cycle costs and reliability of offshore wind turbines (OWTs) is an area of immense interest due to the widespread increase in wind power generation across the world. Most of the existing studies have used structural reliability and the Bayesian pre-posterior analysis for optimization. This paper proposes an extension to the previous approaches in a framework for probabilistic optimization of the total life-cycle costs and reliability of OWTs by combining the elements of structural reliability/risk analysis (SRA), the Bayesian pre-posterior analysis with optimization through a genetic algorithm (GA). The SRA techniques are adopted to compute the probabilities of damage occurrence and failure associated with the deterioration model. The probabilities are used in the decision tree and are updated using the Bayesian analysis. The output of this framework would determine the optimal structural health monitoring and maintenance schedules to be implemented during the life span of OWTs while maintaining a trade-off between the life-cycle costs and risk of the structural failure. Numerical illustrations with a generic deterioration model for one monitoring exercise in the life cycle of a system are demonstrated. Two case scenarios, namely to build initially an expensive and robust or a cheaper but more quickly deteriorating structures and to adopt expensive monitoring system, are presented to aid in the decision-making process.

  14. Improving the Effectiveness of Program Managers

    DTIC Science & Technology

    2006-05-03

    Improving the Effectiveness of Program Managers Systems and Software Technology Conference Salt Lake City, Utah May 3, 2006 Presented by GAO’s...Companies’ best practices Motorola Caterpillar Toyota FedEx NCR Teradata Boeing Hughes Space and Communications Disciplined software and management...and total ownership costs Collection of metrics data to improve software reliability Technology readiness levels and design maturity Statistical

  15. Integration of RAMS in LCC analysis for linear transport infrastructures. A case study for railways.

    NASA Astrophysics Data System (ADS)

    Calle-Cordón, Álvaro; Jiménez-Redondo, Noemi; Morales-Gámiz, F. J.; García-Villena, F. A.; Garmabaki, Amir H. S.; Odelius, Johan

    2017-09-01

    Life-cycle cost (LCC) analysis is an economic technique used to assess the total costs associated with the lifetime of a system in order to support decision making in long term strategic planning. For complex systems, such as railway and road infrastructures, the cost of maintenance plays an important role in the LCC analysis. Costs associated with maintenance interventions can be more reliably estimated by integrating the probabilistic nature of the failures associated to these interventions in the LCC models. Reliability, Maintainability, Availability and Safety (RAMS) parameters describe the maintenance needs of an asset in a quantitative way by using probabilistic information extracted from registered maintenance activities. Therefore, the integration of RAMS in the LCC analysis allows obtaining reliable predictions of system maintenance costs and the dependencies of these costs with specific cost drivers through sensitivity analyses. This paper presents an innovative approach for a combined RAMS & LCC methodology for railway and road transport infrastructures being developed under the on-going H2020 project INFRALERT. Such RAMS & LCC analysis provides relevant probabilistic information to be used for condition and risk-based planning of maintenance activities as well as for decision support in long term strategic investment planning.

  16. Reliability of the Quality of Upper Extremity Skills Test for Children with Cerebral Palsy Aged 2 to 12 Years

    ERIC Educational Resources Information Center

    Thorley, Megan; Lannin, Natasha; Cusick, Anne; Novak, Iona; Boyd, Roslyn

    2012-01-01

    Aim: To investigate reliability of the Quality of Upper Extremity Skills Test (QUEST) scores for children with cerebral palsy (CP) aged 2-12 years. Method: Thirty-one QUESTs from 24 children with CP were rated once by two raters and twice by one rater. Internal consistency of total scores, inter- and intra-rater reliability findings for total,…

  17. Reliability of Measurement of Glenohumeral Internal Rotation, External Rotation, and Total Arc of Motion in 3 Test Positions

    PubMed Central

    Kevern, Mark A.; Beecher, Michael; Rao, Smita

    2014-01-01

    Context: Athletes who participate in throwing and racket sports consistently demonstrate adaptive changes in glenohumeral-joint internal and external rotation in the dominant arm. Measurements of these motions have demonstrated excellent intrarater and poor interrater reliability. Objective: To determine intrarater reliability, interrater reliability, and standard error of measurement for shoulder internal rotation, external rotation, and total arc of motion using an inclinometer in 3 testing procedures in National Collegiate Athletic Association Division I baseball and softball athletes. Design: Cross-sectional study. Setting: Athletic department. Patients or Other Participants Thirty-eight players participated in the study. Shoulder internal rotation, external rotation, and total arc of motion were measured by 2 investigators in 3 test positions. The standard supine position was compared with a side-lying test position, as well as a supine test position without examiner overpressure. Results: Excellent intrarater reliability was noted for all 3 test positions and ranges of motion, with intraclass correlation coefficient values ranging from 0.93 to 0.99. Results for interrater reliability were less favorable. Reliability for internal rotation was highest in the side-lying position (0.68) and reliability for external rotation and total arc was highest in the supine-without-overpressure position (0.774 and 0.713, respectively). The supine-with-overpressure position yielded the lowest interrater reliability results in all positions. The side-lying position had the most consistent results, with very little variation among intraclass correlation coefficient values for the various test positions. Conclusions: The results of our study clearly indicate that the side-lying test procedure is of equal or greater value than the traditional supine-with-overpressure method. PMID:25188316

  18. Chronic ovine evaluation of a totally implantable electrical left ventricular assist system.

    PubMed

    Ramasamy, N; Chen, H; Miller, P J; Jassawalla, J S; Greene, B A; Ocampo, A; Siegel, L C; Oyer, P E; Portner, P M

    1989-01-01

    The totally implantable Novacor left ventricular assist system (LVAS) comprises a pump/drive unit (VAD), electronic control and power subsystem (ECP), variable volume compensator (VVC), and belt skin transformer (BST). The system is now undergoing chronic in vivo evaluation. Cumulative animal testing of VAD, VVC, and BST subsystems are 12.1, 4.9, and 43 years, respectively. The longest implants were 279 days for the VAD, 767 days for the VVC, and 1,148 days for the BST. A chronic implant of the total system was electively terminated at 260 days. The LVAS was powered via the BST. Continuously monitored hemodynamic and pump parameters have demonstrated normal hemodynamics and LVAS operation. Periodic VVC determinations suggest a 0.8 ml/day diffusive gas loss. Tether-free operation has been demonstrated with an Ag-Zn battery backpack. The animal was healthy and free of infection as indicated by routine hematologic, biochemical and serum enzyme determinations. Hemolysis is minimal (plasma free hemoglobin less than 5 mg%). Pump output ranged from 7 to 8 L/min. Severe valve calcification was the reason for elective termination at 260 days. This preclinical in vivo experience, and in vitro reliability studies, demonstrate efficacy of the total system.

  19. Posturography using the Wii Balance Board™: A feasibility study with healthy adults and adults post-stroke.

    PubMed

    Llorens, Roberto; Latorre, Jorge; Noé, Enrique; Keshner, Emily A

    2016-01-01

    Posturography systems that incorporate force platforms are considered to assess balance and postural control with greater sensitivity and objectivity than conventional clinical tests. The Wii Balance Board (WBB) system has been shown to have similar performance characteristics as other force platforms, but with lower cost and size. To determine the validity and reliability of a freely available WBB-based posturography system that combined the WBB with several traditional balance assessments, and to assess the performance of a cohort of stroke individuals with respect to healthy individuals. Healthy subjects and individuals with stroke were recruited. Both groups were assessed using the WBB-based posturography system. Individuals with stroke were also assessed using a laboratory grade posturography system and a battery of clinical tests to determine the concurrent validity of the system. A group of subjects were assessed twice with the WBB-based system to determine its reliability. A total of 144 healthy individuals and 53 individuals with stroke participated in the study. Concurrent validity with another posturography system was moderate to high. Correlations with clinical scales were consistent with previous research. The reliability of the system was excellent in almost all measures. In addition, the system successfully characterized individuals with stroke with respect to the healthy population. The WBB-based posturography system exhibited excellent psychometric properties and sensitivity for identifying balance performance of individuals with stroke in comparison with healthy subjects, which supports feasibility of the system as a clinical tool. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Further Development and Validation of the Affordances in the Home Environment for Motor Development-Infant Scale (AHEMD-IS).

    PubMed

    Caçola, Priscila M; Gabbard, Carl; Montebelo, Maria I L; Santos, Denise C C

    2015-06-01

    Affordances in the home environment may play a significant role in infant motor development. The purpose of this study was to further develop and validate the Affordances in the Home Environment for Motor Development-Infant Scale (AHEMD-IS), an inventory that measures the quantity and quality of motor affordances in the home. A cross-sectional study was conducted to evaluate criteria for content validity, reliability, internal consistency, floor and ceiling effects, and interpretability of the instrument. A pilot version of the inventory with 5 dimensions was used for expert panel analysis and administered to parents of infants (N=419). Data were analyzed with Cronbach alpha, intraclass correlation coefficients (ICCs), ceiling and floor effects, and item and dimension interpretability analyses for creation of a scoring system with descriptive categories for each dimension and total score. Average agreement among the expert panel was 95% across all evaluation criteria. Cronbach alpha values with the 41-item scale ranged between .639 and .824 for the separate dimensions, with a total value of .824 (95% confidence interval [95% CI]=.781, .862). The ICC values were .990 for interrater reliability and .949 for intrarater reliability. There was a ceiling effect on 3 questions for the Inside Space dimension and on 3 questions for the Variety of Stimulation dimension. These results demonstrated the need for reduction in total items (from 41 to 35) and the combination of space dimensions. After removal of questions, internal consistency was .766 (95% CI=.729, .800) for total score. Overall assessment categories were created as: less than adequate, moderately adequate, adequate, and excellent. The inventory does not determine specific use (time, frequency) of affordances in the home, and it does not account for infants' out-of-home activities. The AHEMD-IS is a reliable and valid instrument to assess affordances in the home environment that promote infant motor development. © 2015 American Physical Therapy Association.

  1. Design of a Competency Evaluation Model for Clinical Nursing Practicum, Based on Standardized Language Systems: Psychometric Validation Study.

    PubMed

    Iglesias-Parra, Maria Rosa; García-Guerrero, Alfonso; García-Mayor, Silvia; Kaknani-Uttumchandani, Shakira; León-Campos, Álvaro; Morales-Asencio, José Miguel

    2015-07-01

    To develop an evaluation system of clinical competencies for the practicum of nursing students based on the Nursing Interventions Classification (NIC). Psychometric validation study: the first two phases addressed definition and content validation, and the third phase consisted of a cross-sectional study for analyzing reliability. The study population was undergraduate nursing students and clinical tutors. Through the Delphi technique, 26 competencies and 91 interventions were isolated. Cronbach's α was 0.96. Factor analysis yielded 18 factors that explained 68.82% of the variance. Overall inter-item correlation was 0.26, and total-item correlation ranged between 0.66 and 0.19. A competency system for the nursing practicum, structured on the NIC, is a reliable method for assessing and evaluating clinical competencies. Further evaluations in other contexts are needed. The availability of standardized language systems in the nursing discipline supposes an ideal framework to develop the nursing curricula. © 2015 Sigma Theta Tau International.

  2. Integrated Application of Active Controls (IAAC) technology to an advanced subsonic transport project. ACT/Control/Guidance System study. Volume 2: Appendices

    NASA Technical Reports Server (NTRS)

    1982-01-01

    The integrated application of active controls (IAAC) technology to an advanced subsonic transport is reported. Supplementary technical data on the following topics are included: (1) 1990's avionics technology assessment; (2) function criticality assessment; (3) flight deck system for total control and functional features list; (4) criticality and reliability assessment of units; (5) crew procedural function task analysis; and (6) recommendations for simulation mechanization.

  3. Intelligent Engine Systems: Thermal Management and Advanced Cooling

    NASA Technical Reports Server (NTRS)

    Bergholz, Robert

    2008-01-01

    The objective is to provide turbine-cooling technologies to meet Propulsion 21 goals related to engine fuel burn, emissions, safety, and reliability. Specifically, the GE Aviation (GEA) Advanced Turbine Cooling and Thermal Management program seeks to develop advanced cooling and flow distribution methods for HP turbines, while achieving a substantial reduction in total cooling flow and assuring acceptable turbine component safety and reliability. Enhanced cooling techniques, such as fluidic devices, controlled-vortex cooling, and directed impingement jets, offer the opportunity to incorporate both active and passive schemes. Coolant heat transfer enhancement also can be achieved from advanced designs that incorporate multi-disciplinary optimization of external film and internal cooling passage geometry.

  4. Validity and Reliability Testing of an e-learning Questionnaire for Chemistry Instruction

    NASA Astrophysics Data System (ADS)

    Guspatni, G.; Kurniawati, Y.

    2018-04-01

    The aim of this paper is to examine validity and reliability of a questionnaire used to evaluate e-learning implementation in chemistry instruction. 48 questionnaires were filled in by students who had studied chemistry through e-learning system. The questionnaire consisted of 20 indicators evaluating students’ perception on using e-learning. Parametric testing was done as data were assumed to follow normal distribution. Item validity of the questionnaire was examined through item-total correlation using Pearson’s formula while its reliability was assessed with Cronbach’s alpha formula. Moreover, convergent validity was assessed to see whether indicators building a factor had theoretically the same underlying construct. The result of validity testing revealed 19 valid indicators while the result of reliability testing revealed Cronbach’s alpha value of .886. The result of factor analysis showed that questionnaire consisted of five factors, and each of them had indicators building the same construct. This article shows the importance of factor analysis to get a construct valid questionnaire before it is used as research instrument.

  5. Interrater reliability of the mind map assessment rubric in a cohort of medical students.

    PubMed

    D'Antoni, Anthony V; Zipp, Genevieve Pinto; Olson, Valerie G

    2009-04-28

    Learning strategies are thinking tools that students can use to actively acquire information. Examples of learning strategies include mnemonics, charts, and maps. One strategy that may help students master the tsunami of information presented in medical school is the mind map learning strategy. Currently, there is no valid and reliable rubric to grade mind maps and this may contribute to their underutilization in medicine. Because concept maps and mind maps engage learners similarly at a metacognitive level, a valid and reliable concept map assessment scoring system was adapted to form the mind map assessment rubric (MMAR). The MMAR can assess mind map depth based upon concept-links, cross-links, hierarchies, examples, pictures, and colors. The purpose of this study was to examine interrater reliability of the MMAR. This exploratory study was conducted at a US medical school as part of a larger investigation on learning strategies. Sixty-six (N = 66) first-year medical students were given a 394-word text passage followed by a 30-minute presentation on mind mapping. After the presentation, subjects were again given the text passage and instructed to create mind maps based upon the passage. The mind maps were collected and independently scored using the MMAR by 3 examiners. Interrater reliability was measured using the intraclass correlation coefficient (ICC) statistic. Statistics were calculated using SPSS version 12.0 (Chicago, IL). Analysis of the mind maps revealed the following: concept-links ICC = .05 (95% CI, -.42 to .38), cross-links ICC = .58 (95% CI, .37 to .73), hierarchies ICC = .23 (95% CI, -.15 to .50), examples ICC = .53 (95% CI, .29 to .69), pictures ICC = .86 (95% CI, .79 to .91), colors ICC = .73 (95% CI, .59 to .82), and total score ICC = .86 (95% CI, .79 to .91). The high ICC value for total mind map score indicates strong MMAR interrater reliability. Pictures and colors demonstrated moderate to strong interrater reliability. We conclude that the MMAR may be a valid and reliable tool to assess mind maps in medicine. However, further research on the validity and reliability of the MMAR is necessary.

  6. Interrater reliability of the mind map assessment rubric in a cohort of medical students

    PubMed Central

    D'Antoni, Anthony V; Zipp, Genevieve Pinto; Olson, Valerie G

    2009-01-01

    Background Learning strategies are thinking tools that students can use to actively acquire information. Examples of learning strategies include mnemonics, charts, and maps. One strategy that may help students master the tsunami of information presented in medical school is the mind map learning strategy. Currently, there is no valid and reliable rubric to grade mind maps and this may contribute to their underutilization in medicine. Because concept maps and mind maps engage learners similarly at a metacognitive level, a valid and reliable concept map assessment scoring system was adapted to form the mind map assessment rubric (MMAR). The MMAR can assess mind map depth based upon concept-links, cross-links, hierarchies, examples, pictures, and colors. The purpose of this study was to examine interrater reliability of the MMAR. Methods This exploratory study was conducted at a US medical school as part of a larger investigation on learning strategies. Sixty-six (N = 66) first-year medical students were given a 394-word text passage followed by a 30-minute presentation on mind mapping. After the presentation, subjects were again given the text passage and instructed to create mind maps based upon the passage. The mind maps were collected and independently scored using the MMAR by 3 examiners. Interrater reliability was measured using the intraclass correlation coefficient (ICC) statistic. Statistics were calculated using SPSS version 12.0 (Chicago, IL). Results Analysis of the mind maps revealed the following: concept-links ICC = .05 (95% CI, -.42 to .38), cross-links ICC = .58 (95% CI, .37 to .73), hierarchies ICC = .23 (95% CI, -.15 to .50), examples ICC = .53 (95% CI, .29 to .69), pictures ICC = .86 (95% CI, .79 to .91), colors ICC = .73 (95% CI, .59 to .82), and total score ICC = .86 (95% CI, .79 to .91). Conclusion The high ICC value for total mind map score indicates strong MMAR interrater reliability. Pictures and colors demonstrated moderate to strong interrater reliability. We conclude that the MMAR may be a valid and reliable tool to assess mind maps in medicine. However, further research on the validity and reliability of the MMAR is necessary. PMID:19400964

  7. The validation of the visual analogue scale for patient satisfaction after total hip arthroplasty.

    PubMed

    Brokelman, Roy B G; Haverkamp, Daniel; van Loon, Corné; Hol, Annemiek; van Kampen, Albert; Veth, Rene

    2012-06-01

    INTRODUCTION: Patient satisfaction becomes more important in our modern health care system. The assessment of satisfaction is difficult because it is a multifactorial item for which no golden standard exists. One of the potential methods of measuring satisfaction is by using the well-known visual analogue scale (VAS). In this study, we validated VAS for satisfaction. PATIENT AND METHODS: In this prospective study, we studied 147 patients (153 hips). The construct validity was measured using the Spearman correlation test that compares the satisfaction VAS with the Harris hip score, pain VAS at rest and during activity, Oxford hip score, Short Form 36 and Western Ontario McMaster Universities Osteoarthritis Index. The reliability was tested using the intra-class coefficient. RESULTS: The Pearson correlation test showed correlations in the range of 0.40-0.80. The satisfaction VAS had a high correlation between the pain VAS and Oxford hip score, which could mean that pain is one of the most important factors in patient satisfaction. The intra-class coefficient was 0.95. CONCLUSIONS: There is a moderate to mark degree of correlation between the satisfaction VAS and the currently available subjective and objective scoring systems. The intra-class coefficient of 0.95 indicates an excellent test-retest reliability. The VAS satisfaction is a simple instrument to quantify the satisfaction of a patient after total hip arthroplasty. In this study, we showed that the satisfaction VAS has a good validity and reliability.

  8. A Total Information Management System For All Medical Images

    NASA Astrophysics Data System (ADS)

    Ouimette, Donald; Nudelman, Sol; Ramsby, Gale; Spackman, Thomas

    1985-09-01

    A PACS has been designed for the University of Connecticut Health Center to serve all departments acquiring images for diagnosis, surgery and therapy. It incorporates a multiple community communications architecture to provide complete information management for medical images, medical data and departmental administrative matter. The system is modular and expandable. It permits an initial installation for radiology and subsequent expansion to include other departments at the Health Center, beginning with internal medicine, surgery, ophthalmology and dentistry. The design permits sufficient expansion to offer the potential for accepting the additional burden of a hospital information system. Primary parameters that led to this system design were based on the anticipation that departments in time could achieve generating 60 to 90% of their images suited to insertion in a PACS, that a high network throughput for large block image transfers would be essen-tial and that total system reliability was fundamental to success.

  9. Distributed Computing for the Pierre Auger Observatory

    NASA Astrophysics Data System (ADS)

    Chudoba, J.

    2015-12-01

    Pierre Auger Observatory operates the largest system of detectors for ultra-high energy cosmic ray measurements. Comparison of theoretical models of interactions with recorded data requires thousands of computing cores for Monte Carlo simulations. Since 2007 distributed resources connected via EGI grid are successfully used. The first and the second versions of production system based on bash scripts and MySQL database were able to submit jobs to all reliable sites supporting Virtual Organization auger. For many years VO auger belongs to top ten of EGI users based on the total used computing time. Migration of the production system to DIRAC interware started in 2014. Pilot jobs improve efficiency of computing jobs and eliminate problems with small and less reliable sites used for the bulk production. The new system has also possibility to use available resources in clouds. Dirac File Catalog replaced LFC for new files, which are organized in datasets defined via metadata. CVMFS is used for software distribution since 2014. In the presentation we give a comparison of the old and the new production system and report the experience on migrating to the new system.

  10. Validation of the UCLA Scleroderma Clinical Trial Consortium Gastrointestinal Tract Instrument 2.0 in English- and Chinese-speaking patients in a multi-ethnic Singapore systemic sclerosis cohort.

    PubMed

    Low, Andrea Hsiu Ling; Xin, Xiaohui; Law, Weng Giap; Teng, Gim Gee; Santosa, Amelia; Lim, Anita; Chan, Grace; Ng, Swee Cheng; Thumboo, Julian

    2017-07-01

    The aim of this study was to (1) translate the Gastrointestinal Tract Instrument (GIT) 2.0 from English to Chinese and (2) validate both versions in a multi-ethnic systemic sclerosis cohort in Singapore (SCORE). The English GIT2.0 was translated to Chinese using a standard forward-backward translation approach. Psychometric evaluation of the GIT2.0 included internal consistency reliability (using Cronbach's alpha), test-retest reliability (using intra-class correlation coefficient (ICC)), scale level factor analysis, and construct validity (using Spearman correlation) against the modified Scleroderma Health Assessment Questionnaire (S-HAQ) and the SF-36 v2. Most of the patients were females (88.6%) and Chinese (78.2%), with mean (SD) age of 51.0 (13.0) years and median disease duration of 4.5 years. We administered English (n = 146) and Chinese (n = 74) GIT2.0. The mean (SD) total GIT score was 0.29 (0.37). There was good internal consistency (Cronbach's alpha >0.70 for all subscales) and good test-retest reliability for the scale and all subscales (ICC 0.71-0.92) except for "diarrhoea" (ICC = 0.54). Our hypothesised a priori construct validity was supported by moderate correlations between the total GIT score and S-HAQ GI subscale (r = 0.446), and the social functioning subscale and SF36v2 role-social domain (r = 0.337), and weak-to-moderate correlation between the emotional subscale and SF-36v2 role-emotional (r = 0.295) and mental health (r = 0.298) domains and mental component summary (r = 0.356). Exploratory factor analysis of the seven subscales yielded a two-factor solution explaining 69.63% of the total variance. This study provides evidence for the reliability and validity of the English and Chinese GIT2.0 to be used in Singapore for research and routine practice.

  11. Reliability of classification for post-traumatic ankle osteoarthritis.

    PubMed

    Claessen, Femke M A P; Meijer, Diederik T; van den Bekerom, Michel P J; Gevers Deynoot, Barend D J; Mallee, Wouter H; Doornberg, Job N; van Dijk, C Niek

    2016-04-01

    The purpose of this study was to identify the most reliable classification system for clinical outcome studies to categorize post-traumatic-fracture-osteoarthritis. A total of 118 orthopaedic surgeons and residents-gathered in the Ankle Platform Study Collaborative Science of Variation Group-evaluated 128 anteroposterior and lateral radiographs of patients after a bi- or trimalleolar ankle fracture on a Web-based platform in order to rate post-traumatic osteoarthritis according to the classification systems coined by (1) van Dijk, (2) Kellgren, and (3) Takakura. Reliability was evaluated with the use of the Siegel and Castellan's multirater kappa measure. Differences between classification systems were compared using the two-sample Z-test. Interobserver agreement of surgeons who participated in the survey was fair for the van Dijk osteoarthritis scale (k = 0.24), and poor for the Takakura (k = 0.19) and the Kellgren systems (k = 0.18) according to the categorical rating of Landis and Koch. This difference in one categorical rating was found to be significant (p < 0.001, CI 0.046-0.053) with the high numbers of observers and cases available. This study documents fair interobserver agreement for the van Dijk osteoarthritis scale, and poor interobserver agreement for the Takakura and Kellgren osteoarthritis classification systems. Because of the low interobserver agreement for the van Dijk, Kellgren, and Takakura classification systems, those systems cannot be used for clinical decision-making. Development of diagnostic criteria on basis of consecutive patients, Level II.

  12. Concept for Space Technology Advancement

    NASA Astrophysics Data System (ADS)

    Hansen, Jeremiah J.

    2005-02-01

    The space industry is based on an antiquated concept of disposable rockets, earth construction, and non-repairable satellites. Current space vehicle concepts hearken from a time of Cold War animosity and expeditiousness. Space systems are put together in small, single-purpose chunks that are launched with mighty, single-use rockets. Spacecraft need to change to a more versatile, capable, reusable, and mission efficient design. The Crew Exploration Vehicle (CEV) that President Bush put forward in his space initiative on Jan. 14, 2004 is a small first step. But like all first steps, the risk of eventual failure is great without a complementary set of steps, a reliable handhold, and a goal, which are outlined in this paper. The system for space access and development needs to be overhauled to allow for the access to space to complement the building in space, which promotes the production of goods in space, which enhances the exploitation of space resources… and the list goes on. Without supplemental and complementary infrastructure, all political, scientific, and idealistic endeavors to explore and exploit the near solar system will result in quagmires of failures and indecision. Renewed focus on fundamentals, integration, total-system consideration, and solid engineering can avoid catastrophe. Mission success, simple solutions, mission efficiency, and proper testing all seem to have been lost in the chase for the nickels and dimes. These items will increase capabilities available from a system or combination of systems. New propulsion options and materials will enable vehicles previously unachievable. Future spacecraft should exploit modular designs for repeatability and reduced cost. Space construction should use these modular systems on major components built in orbit. All vehicles should apply smart designs and monitoring systems for increased reliability and system awareness. Crew safety systems must use this awareness in alerting the crew, aiding collision detection and avoidance, damage control and mitigation, and crew ejection systems. These systems, working together, will greatly increase survivability of crewed systems. Implicit in this varied list of technology and integration is industry risk. Aerospace industry must relearn to accept risk in space technology development in order to advance capability. All of these items wrap up in a total system view that will allow for more advanced, reliable capability in space.

  13. Reliability of hospital cost profiles in inpatient surgery.

    PubMed

    Grenda, Tyler R; Krell, Robert W; Dimick, Justin B

    2016-02-01

    With increased policy emphasis on shifting risk from payers to providers through mechanisms such as bundled payments and accountable care organizations, hospitals are increasingly in need of metrics to understand their costs relative to peers. However, it is unclear whether Medicare payments for surgery can reliably compare hospital costs. We used national Medicare data to assess patients undergoing colectomy, pancreatectomy, and open incisional hernia repair from 2009 to 2010 (n = 339,882 patients). We first calculated risk-adjusted hospital total episode payments for each procedure. We then used hierarchical modeling techniques to estimate the reliability of total episode payments for each procedure and explored the impact of hospital caseload on payment reliability. Finally, we quantified the number of hospitals meeting published reliability benchmarks. Mean risk-adjusted total episode payments ranged from $13,262 (standard deviation [SD] $14,523) for incisional hernia repair to $25,055 (SD $22,549) for pancreatectomy. The reliability of hospital episode payments varied widely across procedures and depended on sample size. For example, mean episode payment reliability for colectomy (mean caseload, 157) was 0.80 (SD 0.18), whereas for pancreatectomy (mean caseload, 13) the mean reliability was 0.45 (SD 0.27). Many hospitals met published reliability benchmarks for each procedure. For example, 90% of hospitals met reliability benchmarks for colectomy, 40% for pancreatectomy, and 66% for incisional hernia repair. Episode payments for inpatient surgery are a reliable measure of hospital costs for commonly performed procedures, but are less reliable for lower volume operations. These findings suggest that hospital cost profiles based on Medicare claims data may be used to benchmark efficiency, especially for more common procedures. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Reliability testing of a portfolio assessment tool for postgraduate family medicine training in South Africa

    PubMed Central

    Mash, Bob; Derese, Anselme

    2013-01-01

    Abstract Background Competency-based education and the validity and reliability of workplace-based assessment of postgraduate trainees have received increasing attention worldwide. Family medicine was recognised as a speciality in South Africa six years ago and a satisfactory portfolio of learning is a prerequisite to sit the national exit exam. A massive scaling up of the number of family physicians is needed in order to meet the health needs of the country. Aim The aim of this study was to develop a reliable, robust and feasible portfolio assessment tool (PAT) for South Africa. Methods Six raters each rated nine portfolios from the Stellenbosch University programme, using the PAT, to test for inter-rater reliability. This rating was repeated three months later to determine test–retest reliability. Following initial analysis and feedback the PAT was modified and the inter-rater reliability again assessed on nine new portfolios. An acceptable intra-class correlation was considered to be > 0.80. Results The total score was found to be reliable, with a coefficient of 0.92. For test–retest reliability, the difference in mean total score was 1.7%, which was not statistically significant. Amongst the subsections, only assessment of the educational meetings and the logbook showed reliability coefficients > 0.80. Conclusion This was the first attempt to develop a reliable, robust and feasible national portfolio assessment tool to assess postgraduate family medicine training in the South African context. The tool was reliable for the total score, but the low reliability of several sections in the PAT helped us to develop 12 recommendations regarding the use of the portfolio, the design of the PAT and the training of raters.

  15. Two-stage stochastic unit commitment model including non-generation resources with conditional value-at-risk constraints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Yuping; Zheng, Qipeng P.; Wang, Jianhui

    2014-11-01

    tThis paper presents a two-stage stochastic unit commitment (UC) model, which integrates non-generation resources such as demand response (DR) and energy storage (ES) while including riskconstraints to balance between cost and system reliability due to the fluctuation of variable genera-tion such as wind and solar power. This paper uses conditional value-at-risk (CVaR) measures to modelrisks associated with the decisions in a stochastic environment. In contrast to chance-constrained modelsrequiring extra binary variables, risk constraints based on CVaR only involve linear constraints and con-tinuous variables, making it more computationally attractive. The proposed models with risk constraintsare able to avoid over-conservative solutions butmore » still ensure system reliability represented by loss ofloads. Then numerical experiments are conducted to study the effects of non-generation resources ongenerator schedules and the difference of total expected generation costs with risk consideration. Sen-sitivity analysis based on reliability parameters is also performed to test the decision preferences ofconfidence levels and load-shedding loss allowances on generation cost reduction.« less

  16. Measurement-While-Drilling (MWD) development for air drilling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harrison, W.A.; Rubin, L.A.

    1993-12-31

    When downhole contact between the BHA and formation was optimum, as it was during rotation, high signal levels were experienced. Survey data acquired at the connections, when the BHA was totally at rest, is excellent. GEC intends modifying the system to optimize operations consistent with these disparate factors. A Mean-Time-To-Failure (MTTF) of 89.9 hours appears reasonable from the data. It is not possible to infer an MTBF figure from this test. It is quite obvious, however, that the system reliability performance has been significantly improved since FT {number_sign}5 was performed almost two years earlier. Based on the above results, GECmore » concludes that it is certainly feasible to attain 100 hours MTBF, for the Model 27, in any and all situations, and hence to provide a reliable MWD for air-drilling.« less

  17. Cross-cultural adaptation and validation of Persian Achilles tendon Total Rupture Score.

    PubMed

    Ansari, Noureddin Nakhostin; Naghdi, Soofia; Hasanvand, Sahar; Fakhari, Zahra; Kordi, Ramin; Nilsson-Helander, Katarina

    2016-04-01

    To cross-culturally adapt the Achilles tendon Total Rupture Score (ATRS) to Persian language and to preliminary evaluate the reliability and validity of a Persian ATRS. A cross-sectional and prospective cohort study was conducted to translate and cross-culturally adapt the ATRS to Persian language (ATRS-Persian) following steps described in guidelines. Thirty patients with total Achilles tendon rupture and 30 healthy subjects participated in this study. Psychometric properties of floor/ceiling effects (responsiveness), internal consistency reliability, test-retest reliability, standard error of measurement (SEM), smallest detectable change (SDC), construct validity, and discriminant validity were tested. Factor analysis was performed to determine the ATRS-Persian structure. There were no floor or ceiling effects that indicate the content and responsiveness of ATRS-Persian. Internal consistency was high (Cronbach's α 0.95). Item-total correlations exceeded acceptable standard of 0.3 for the all items (0.58-0.95). The test-retest reliability was excellent [(ICC)agreement 0.98]. SEM and SDC were 3.57 and 9.9, respectively. Construct validity was supported by a significant correlation between the ATRS-Persian total score and the Persian Foot and Ankle Outcome Score (PFAOS) total score and PFAOS subscales (r = 0.55-0.83). The ATRS-Persian significantly discriminated between patients and healthy subjects. Explanatory factor analysis revealed 1 component. The ATRS was cross-culturally adapted to Persian and demonstrated to be a reliable and valid instrument to measure functional outcomes in Persian patients with Achilles tendon rupture. II.

  18. A Methodology for Quantifying Certain Design Requirements During the Design Phase

    NASA Technical Reports Server (NTRS)

    Adams, Timothy; Rhodes, Russel

    2005-01-01

    A methodology for developing and balancing quantitative design requirements for safety, reliability, and maintainability has been proposed. Conceived as the basis of a more rational approach to the design of spacecraft, the methodology would also be applicable to the design of automobiles, washing machines, television receivers, or almost any other commercial product. Heretofore, it has been common practice to start by determining the requirements for reliability of elements of a spacecraft or other system to ensure a given design life for the system. Next, safety requirements are determined by assessing the total reliability of the system and adding redundant components and subsystems necessary to attain safety goals. As thus described, common practice leaves the maintainability burden to fall to chance; therefore, there is no control of recurring costs or of the responsiveness of the system. The means that have been used in assessing maintainability have been oriented toward determining the logistical sparing of components so that the components are available when needed. The process established for developing and balancing quantitative requirements for safety (S), reliability (R), and maintainability (M) derives and integrates NASA s top-level safety requirements and the controls needed to obtain program key objectives for safety and recurring cost (see figure). Being quantitative, the process conveniently uses common mathematical models. Even though the process is shown as being worked from the top down, it can also be worked from the bottom up. This process uses three math models: (1) the binomial distribution (greaterthan- or-equal-to case), (2) reliability for a series system, and (3) the Poisson distribution (less-than-or-equal-to case). The zero-fail case for the binomial distribution approximates the commonly known exponential distribution or "constant failure rate" distribution. Either model can be used. The binomial distribution was selected for modeling flexibility because it conveniently addresses both the zero-fail and failure cases. The failure case is typically used for unmanned spacecraft as with missiles.

  19. A spaceworthy ADR - Recent developments. [Adiabatic Demagnetization Refrigerator for X ray spectrometer

    NASA Technical Reports Server (NTRS)

    Serlemitsos, Aristides T.; Warner, Brent A.; Sansebastian, Marcelino; Kunes, Evan

    1990-01-01

    Recent developments concerning the performance and reliability of a spaceworthy adiabatic demagnetization refrigerator (ADR) for the AXAF X-ray spectrometer are considered. They include a procedure for growing the salt pill around a harness made up of 6080 gold-plated copper wires, a totally modular gas gap heat switch, and a suspension system utilizing Kevlar fibers.

  20. Issues in Public Examinations: A Selection of the Proceedings of the 1990 IAEA Conference (16th, Maastricht, Netherlands, June 1990).

    ERIC Educational Resources Information Center

    Luijten, Anton J. M., Ed.

    This collection of 18 papers (selected from a total of 57 presented at a conference of the International Association for Educational Assessment) represents efforts by examining bodies and institutes to: improve the examination system and testing techniques; develop reliable instruments; and establish standards for public examinations. The papers…

  1. Analysis of the reliability and validity of the Turkish version of the intermittent and constant osteoarthritis pain questionnaire.

    PubMed

    Erel, Suat; Şimşek, İbrahim Engin; Özkan, Hüseyin

    2015-01-01

    The aim of this study was to analyze the validity and reliability of the Turkish version (ICOAP-TR) of the intermittent and constant osteoarthritis pain (ICOAP) questionnaire in patients with knee osteoarthritis (OA). Thirty-eight volunteer patients diagnosed with knee OA answered the questionnaire twice with an interval of 2-4 days. The reliability of the measurement was assessed using Cronbach's alpha coefficient and intraclass correlation (ICC) for test-retest reliability. Criterion validity was tested against the Western Ontario and McMaster Universities Arthritis Index (WOMAC) pain score and visual analog scale (VAS) designed to assess the perceived discomfort rated by the patient. Test-retest reliability was found to be ICC=0.942 for total score, 0.902 for constant pain subscale, and 0.945 for intermittent pain subscale. Internal consistency was tested using Cronbach's alpha and was found to be 0.970 for total score, 0.948 for constant pain subscale, and 0.972 for intermittent pain subscale. For criterion validity, the correlation between the total score of ICOAP-TR and WOMAC pain subscale was r=0.779 (p<0.05), and correlation between total score of ICOAP-TR and VAS was r=0.570 (p<0.05). The ICOAP-TR is a reliable and valid instrument to be used with patients with knee OA.

  2. Evaluating the test-retest reliability of symptom indices associated with the ImPACT post-concussion symptom scale (PCSS).

    PubMed

    Merritt, Victoria C; Bradson, Megan L; Meyer, Jessica E; Arnett, Peter A

    2018-05-01

    The Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) is a commonly used tool in sports concussion assessment. While test-retest reliabilities have been established for the ImPACT cognitive composites, few studies have evaluated the psychometric properties of the ImPACT's Post-Concussion Symptom Scale (PCSS). The purpose of this study was to establish the test-retest reliability of symptom indices associated with the PCSS. Participants included 38 undergraduate students (50.0% male) who underwent neuropsychological testing as part of their participation in their psychology department's research subject pool. The majority of the participants were Caucasian (94.7%) and had no history of concussion (73.7%). All participants completed the ImPACT at two time points, approximately 6 weeks apart. The PCSS was the main outcome measure, and eight symptom indices were calculated (a total symptom score, three symptom summary indices, and four symptom clusters). Pearson correlations (r) and intraclass correlation coefficients (ICCs) were computed as measures of test-retest reliability. Overall, reliabilities ranged from low to high (r = .44 to .80; ICC = .44 to .77). The cognitive symptom cluster exhibited the highest test-retest reliability (r = .80, ICC = .77), followed by the positive symptom total (PST) index, an indicator of the total number of symptoms endorsed (r = .71, ICC = .69). In contrast, the commonly used total symptom score showed lower test-retest reliability (r = .67, ICC = .62). Paired-samples t tests revealed no significant differences between test and retest for any of the symptom variables (all p > .01). Finally, reliable change indices (RCI) were computed to determine whether differences observed between test and retest represented clinically significant change. RCI values were provided for each symptom index at the 80%, 90%, and 95% confidence intervals. These results suggest that evaluating additional symptom indices beyond the total symptom score from the PCSS is beneficial. Findings from this study can be applied to athlete samples to assess reliable change in symptoms following concussion.

  3. Energy Systems Integration: Data Call -- Become a Data Partner

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2017-01-01

    This project aims to advance the understanding of costs associated with integrating PV onto the electric power distribution system while maintaining reliable grid operations. We have developed a bottom-up framework for calculating these costs as a function of PV penetration levels on specific feeders. This framework will used to inform and improve utility planning decisions, increase the transparency and speed associated with the interconnection process, and provide policymakers with more information on the total cost of energy from PV.

  4. Reliability of the Adult Myopathy Assessment Tool in Individuals with Myositis

    PubMed Central

    Harris-Love, Michael O.; Joe, Galen; Davenport, Todd E.; Koziol, Deloris; Rose, Kristen Abbett; Shrader, Joseph A.; Vasconcelos, Olavo M.; McElroy, Beverly; Dalakas, Marinos C.

    2015-01-01

    Objective The Adult Myopathy Assessment Tool (AMAT) is a 13-item performance-based battery developed to assess functional status and muscle endurance. The purpose of this study was to determine the intrarater and interrater reliability of the AMAT in adults with myosits. Methods Nineteen raters (13 physical therapists and 6 physicians) scored videotaped recordings of patients with myositis performing the AMAT for a total of 114 tests and 1,482 item observations per session. Raters rescored the AMAT test and item observations during a follow up session (19 ±6 days between scoring sessions). All raters completed a single, self-directed, electronic training module prior to the initial scoring session. Results Intrarater and interrater reliability correlation coefficients were .94 or greater for the AMAT Functional Subscale, Endurance Subscale, and Total score (all p < 0.02 for Ho:ρ ≤ 0.75). All AMAT items had satisfactory intrarater agreement (Kappa statistics with Fleiss-Cohen weights, Kw = .57-1.00). Interrater agreement was acceptable for each AMAT item (K = .56-.89) except the sit up (K = .16). The standard error of measurement and 95% confidence interval range for the AMAT Total scores did not exceed 2 points across all observations (AMAT Total score range = 0-45). Conclusions The AMAT is a reliable, domain-specific assessment of functional status and muscle endurance for adult subjects with myositis. Results of this study suggest that physicians and physical therapists may reliably score the AMAT following a single training session. The AMAT Functional Subscale, Endurance Subscale, and Total score exhibit interrater and intrarater reliability suitable for clinical and research use. PMID:25201624

  5. Validity and reliability of the Turkish Migraine Disability Assessment (MIDAS) questionnaire.

    PubMed

    Ertaş, Mustafa; Siva, Aksel; Dalkara, Turgay; Uzuner, Nevzat; Dora, Babür; Inan, Levent; Idiman, Fethi; Sarica, Yakup; Selçuki, Deniz; Sirin, Hadiye; Oğuzhanoğlu, Atilla; Irkeç, Ceyla; Ozmenoğlu, Mehmet; Ozbenli, Taner; Oztürk, Musa; Saip, Sabahattin; Neyal, Münife; Zarifoğlu, Mehmet

    2004-09-01

    The aim of this study is to assess the comprehensibility, internal consistency, patient-physician reliability, test-retest reliability, and validity of Turkish version of Migraine Disability Assessment (MIDAS) questionnaire in patients with headache. MIDAS questionnaire has been developed by Stewart et al and shown to be reliable and valid to determine the degree of disability caused by migraine. This study was designed as a national multicenter study to demonstrate the reliability and validity of Turkish version of MIDAS questionnaire. Patients applying to 17 Neurology Clinics in Turkey were evaluated at the baseline (visit 1), week 4 (visit 2), and week 12 (visit 3) visits in terms of disease severity and comprehensibility, internal consistency, test-retest reliability, and validity of MIDAS. Since the severity of the disease has been found to change significantly at visit 2 compared to visit 1, test-retest reliability was assessed using the MIDAS scores of a subgroup of patients whose disease severity remained unchanged (up to +/-3 days difference in the number of days with headache between visits 1 and 2). A total of 306 patients (86.2% female, mean age: 35.0 +/- 9.8 years) were enrolled into the study. A total of 65.7%, 77.5%, 82.0% of patients reported that "they had fully understood the MIDAS questionnaire" in visits 1, 2, and 3, respectively. A highly positive correlation was found between physician and patient and the applied total MIDAS scores in all three visits (Spearman correlation coefficients were R= 0.87, 0.83, and 0.90, respectively, P <.001). Internal consistency of MIDAS was assessed using Cronbach's alpha and was found at acceptable (>0.7) or excellent (>0.8) levels in both patient and physician applied MIDAS scores, respectively. Total MIDAS score showed good test-retest reliability (R= 0.68). Both the number of days with headache and the total MIDAS scores were positively correlated at all visits with correlation coefficients between 0.47 and 0.63. There was also a moderate degree of correlation (R= 0.54) between the total MIDAS score at week 12 and the number of days with headache at visit 2 + visit 3, which quantify headache-related disability over a 3-month period similar to MIDAS questionnaire. These findings demonstrated that the Turkish translation is equivalent to the English version of MIDAS in terms of internal consistency, test-retest reliability, and validity. Physicians can reliably use the Turkish translation of the MIDAS questionnaire in defining the severity of illness and its treatment strategy when applied as a self-administered report by migraine patients themselves.

  6. Preliminary validation of 2 magnetic resonance image scoring systems for osteoarthritis of the hip according to the OMERACT filter.

    PubMed

    Maksymowych, Walter P; Cibere, Jolanda; Loeuille, Damien; Weber, Ulrich; Zubler, Veronika; Roemer, Frank W; Jaremko, Jacob L; Sayre, Eric C; Lambert, Robert G W

    2014-02-01

    Development of a validated magnetic resonance image (MRI) scoring system is essential in hip OA because radiographs are insensitive to change. We assessed the feasibility and reliability of 2 previously developed scoring methods: (1) the Hip Inflammation MRI Scoring System (HIMRISS) and (2) the Hip Osteoarthritis MRI Scoring System (HOAMS). Six readers (3 radiologists, 3 rheumatologists) participated in 2 reading exercises. In Reading Exercise 1, MRI of the hip of 20 subjects were read at a single time point followed by further standardization of methodology. In Reading Exercise 2, MRI of the hip of 18 subjects from a randomized controlled trial, assessed at 2 timepoints, and 27 subjects from a cross-sectional study were read for HIMRISS and HOAMS bone marrow lesions (BML) and synovitis. Reliability was assessed using intraclass correlation coefficient (ICC) and kappa statistics. Both methods were considered feasible. For Reading 1, HIMRISS ICC were 0.52, 0.61, 0.70, and 0.58 for femoral BML, acetabular BML, effusion, and total scores, respectively; and for HOAMS, summed BML and synovitis ICC were 0.52 and 0.46, respectively. For Reading 2, HIMRISS and HOAMS ICC for BML and synovitis-effusion improved substantially. Interobserver reliability for change scores was 0.81 and 0.71 for HIMRISS femoral and HOAMS summed BML, respectively. Responsiveness and discrimination was moderate to high for synovitis-effusion. Significant associations were noted between BML or synovitis scores and Western Ontario and McMaster Universities Osteoarthritis Index pain scores for baseline values (p ≤ 0.001). The BML and synovitis-effusion components of both HIMRISS and HOAMS scoring systems are feasible and reliable, and should be validated further.

  7. Reliability and Validity of the Chinese Version of FACIT-AI, a New Tool for Assessing Quality of Life in Patients with Malignant Ascites.

    PubMed

    Lou, Yanni; Lu, Linghui; Li, Yuan; Liu, Meng; Bredle, Jason M; Jia, Liqun

    2015-10-01

    The study objective was to determine the reliability and validity of the Chinese version of the Functional Assessment of Chronic Illness Therapy - Ascites Index (FACIT-AI). A forward-backward translation procedure was adopted to develop the Chinese version of the FACIT-AI, which was tested in 69 patients with malignant ascites. Cronbach's α, split-half reliability, and test-retest reliability were used to assess the reliability of the scale. The content validity index was used to assess the content validity, while factor analysis was used for construct validity and correlation analysis was used for criterion validity. The Cronbach's α was 0.772 for the total scale, and the split-half reliability was 0.693. The test-retest correlation was 0.972. The content validity index for the scale was 0.8-1.0. Four factors were extracted by factor analysis, and these contributed 63.51% of the total variance. Item-total correlations ranged from 0.591 to 0.897, and these were correlated with visual analog scale scores (correlation coefficient, 0.889; P<0.01). The Chinese version of the FACIT-AI has good reliability and validity and can be used as a tool to measure quality of life in Chinese patients with malignant ascites.

  8. Intrajudge and Interjudge Reliability of the Stuttering Severity Instrument-Fourth Edition.

    PubMed

    Davidow, Jason H; Scott, Kathleen A

    2017-11-08

    The Stuttering Severity Instrument (SSI) is a tool used to measure the severity of stuttering. Previous versions of the instrument have known limitations (e.g., Lewis, 1995). The present study examined the intra- and interjudge reliability of the newest version, the Stuttering Severity Instrument-Fourth Edition (SSI-4) (Riley, 2009). Twelve judges who were trained on the SSI-4 protocol participated. Judges collected SSI-4 data while viewing 4 videos of adults who stutter at Time 1 and 4 weeks later at Time 2. Data were analyzed for intra- and interjudge reliability of the SSI-4 subscores (for Frequency, Duration, and Physical Concomitants), total score, and final severity rating. Intra- and interjudge reliability across the subscores and total score concurred with the manual's reported reliability when reliability was calculated using the methods described in the manual. New calculations of judge agreement produced different values from those in the manual-for the 3 subscores, total score, and final severity rating-and provided data absent from the manual. Clinicians and researchers who use the SSI-4 should carefully consider the limitations of the instrument. Investigation into the multitasking demands of the instrument may provide information on whether separating the collection of data for specific variables will improve intra- and interjudge reliability of those variables.

  9. Quantitation of total homocysteine in human plasma by derivatization to its N(O,S)-propoxycarbonyl propyl ester and gas chromatography-mass spectrometry analysis.

    PubMed

    Sass, J O; Endres, W

    1997-08-01

    Much evidence supports the hypothesis that mild or moderate hyperhomocysteinaemia represents an important and independent risk factor for occlusive vascular diseases. Therefore, the accurate and reliable determination of total plasma homocysteine has gained major importance for risk assessment. Furthermore, it can help in the detection of folate and vitamin B12 deficiency. This has prompted us to develop a sensitive gas chromatography-mass spectrometry (GC-MS) method in order to quantify total homocysteine in human plasma. Prior to chromatography, reduced homocysteine was released from disulfide bonds by incubation with excess dithiothreitol and converted into its N(O,S)-propoxycarbonyl propyl ester by derivatization with n-propyl chloroformate. Aminoethylcysteine served as internal standard. The method proved to be highly linear over the entire concentration range examined (corresponding to 0-266 microM homocysteine) and showed intra-assay and inter-assay variation (relative standard deviations) of approximately 5 and 5-10%, respectively. External quality control by comparison with duplicate analysis performed on a HPLC-based system revealed satisfactory correlation. The newly developed GC-MS based method provides simple, reliable and fast quantification of total homocysteine and requires only inexpensive chemicals, which are easy to obtain.

  10. Early warning indicators for monitoring the process failure of anaerobic digestion system of food waste.

    PubMed

    Li, Lei; He, Qingming; Wei, Yunmei; He, Qin; Peng, Xuya

    2014-11-01

    To determine reliable state parameters which could be used as early warning indicators of process failure due to the acidification of anaerobic digestion of food waste, three mesophilic anaerobic digesters of food waste with different operation conditions were investigated. Such parameters as gas production, methane content, pH, concentrations of volatile fatty acid (VFA), alkalinity and their combined indicators were evaluated. Results revealed that operation conditions significantly affect the responses of parameters and thus the optimal early warning indicators of each reactor differ from each other. None of the single indicators was universally valid for all the systems. The universally valid indicators should combine several parameters to supply complementary information. A combination of total VFA, the ratio of VFA to total alkalinity (VFA/TA) and the ratio of bicarbonate alkalinity to total alkalinity (BA/TA) can reflect the metabolism of the digesting system and realize rapid and effective early warning. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. [Reliability and validity of Meaningful Life Measure-Chinese Revised in Chinese college students].

    PubMed

    Xiao, Rong; Lai, Qiao-Zhen; Yang, Jia-Ping

    2016-04-20

    To test the reliability and validity of Meaningful Life Measure-Chinese Revised (MLM-CR) in Chinese college students. A total of 1035 college students were evaluated with MLM-CR, Satisfaction with Life Scale (SWLS), Purpose in Life (PIL) and Patient Health Questionnaire-2 (PHQ-2), and 120 of the students were examined with PIL-SF twice. All the items in MLM-CR had good discrimination indexes (r=0.753-0.838, P<0.001). Confirmatory factor analysis confirmed the hypothesized five-factor model of MLM-CR (Χ 2 /df=3.4, GFI=0.946, AGFI=0.924, RMR=0.069, NFI=0.953, CFI=0.966, RMSEA=0.048). The total internal consistency reliability of MLM-CR was 0.942, and the alpha coefficients of the 5 dimensions ranged from 0.782 to 0.877; the total split-half reliability was 0.920, and the split-half reliability of the 5 dimensions ranged from 0.752 to 0.830; the total test-retest reliability was 0.871, and the test-retest reliability of the 5 dimensions ranged from 0.783 to 0.805. The criterion validity of MLM-CR in correlation with SWLS, PIL and PHQ-2 was 0.66, 0.755 and -0.388, respectively (P<0.01). The Average score of MLM-CR of the college students was 5.20∓0.90, and the scores were significantly higher in female students than in the male students (P<0.001). MLM-CR has good psychometric properties for application in comprehensive evaluation of personal meaning in life.

  12. Spacecraft Conceptual Design Compared to the Apollo Lunar Lander

    NASA Technical Reports Server (NTRS)

    Young, C.; Bowie, J.; Rust, R.; Lenius, J.; Anderson, M.; Connolly, J.

    2011-01-01

    Future human exploration of the Moon will require an optimized spacecraft design with each sub-system achieving the required minimum capability and maintaining high reliability. The objective of this study was to trade capability with reliability and minimize mass for the lunar lander spacecraft. The NASA parametric concept for a 3-person vehicle to the lunar surface with a 30% mass margin totaled was considerably heavier than the Apollo 15 Lunar Module "as flown" mass of 16.4 metric tons. The additional mass was attributed to mission requirements and system design choices that were made to meet the realities of modern spaceflight. The parametric tool used to size the current concept, Envision, accounts for primary and secondary mass requirements. For example, adding an astronaut increases the mass requirements for suits, water, food, oxygen, as well as, the increase in volume. The environmental control sub-systems becomes heavier with the increased requirements and more structure was needed to support the additional mass. There was also an increase in propellant usage. For comparison, an "Apollo-like" vehicle was created by removing these additional requirements. Utilizing the Envision parametric mass calculation tool and a quantitative reliability estimation tool designed by Valador Inc., it was determined that with today?s current technology a Lunar Module (LM) with Apollo capability could be built with less mass and similar reliability. The reliability of this new lander was compared to Apollo Lunar Module utilizing the same methodology, adjusting for mission timeline changes as well as component differences. Interestingly, the parametric concept's overall estimated risk for loss of mission (LOM) and loss of crew (LOC) did not significantly improve when compared to Apollo.

  13. Gallium-68 DOTATATE Production with Automated PET Radiopharmaceutical Synthesis System: A Three Year Experience.

    PubMed

    Aslani, Alireza; Snowdon, Graeme M; Bailey, Dale L; Schembri, Geoffrey P; Bailey, Elizabeth A; Roach, Paul J

    2014-01-01

    Gallium-68 (Ga-68) is an ideal research and hospital-based PET radioisotope. Currently, the main form of Ga-68 radiopharmaceutical that is being synthesised in-house is Ga-68 conjugated with DOTA based derivatives. The development of automated synthesis systems has increased the reliability, reproducibility and safety of radiopharmaceutical productions. Here we report on our three year, 500 syntheses experience with an automated system for Ga-68 DOTATATE. The automated synthesis system we use is divided into three parts of a) servomotor modules, b) single use sterile synthesis cassettes and, c) a computerised system that runs the modules. An audit trail is produced by the system as a requirement for GMP production. The required reagents and chemicals are made in-. The Germanium breakthrough is determined on a weekly basis. Production yields for each synthesis are calculated to monitor the performance and efficiency of the synthesis. The quality of the final product is assessed after each synthesis by ITLC-SG and HPLC methods. A total of 500 Ga-68 DOTATATE syntheses (>800 patient doses) were performed between March 2011 and February 2014. The average generator yield was 81.3±0.2% for 2011, 76.7±0.4% for 2012 and 75.0±0.3% for 2013. Ga-68 DOTATATE yields for 2011, 2012, and 2013 were 81.8±0.4%, 82.2±0.4% and 87.9±0.4%, respectively. These exceed the manufacturer's expected value of approximately 70%. Germanium breakthrough averaged 8.6×10(-6)% of total activity which is well below the recommended level of 0.001%. The average ITLC-measured radiochemical purity was above 98.5% and the average HPLC-measured radiochemical purity was above 99.5%. Although there were some system failures during synthesis, there were only eight occasions where the patient scans needed to be rescheduled. In our experience the automated synthesis system performs reliably with a relatively low incident of failures. Our system had a consistent and reliable Ga-68 DOTATATE output with high labelling efficiency and purity. There is minimal operator intervention and radiation exposure. The system is GMP-compliant and has low maintenance and acceptable running costs. This system together with the recommended (68)Ge/(68)Ga generator is well suited for use in a hospital-based radiopharmacy.

  14. Product reliability and thin-film photovoltaics

    NASA Astrophysics Data System (ADS)

    Gaston, Ryan; Feist, Rebekah; Yeung, Simon; Hus, Mike; Bernius, Mark; Langlois, Marc; Bury, Scott; Granata, Jennifer; Quintana, Michael; Carlson, Carl; Sarakakis, Georgios; Ogden, Douglas; Mettas, Adamantios

    2009-08-01

    Despite significant growth in photovoltaics (PV) over the last few years, only approximately 1.07 billion kWhr of electricity is estimated to have been generated from PV in the US during 2008, or 0.27% of total electrical generation. PV market penetration is set for a paradigm shift, as fluctuating hydrocarbon prices and an acknowledgement of the environmental impacts associated with their use, combined with breakthrough new PV technologies, such as thin-film and BIPV, are driving the cost of energy generated with PV to parity or cost advantage versus more traditional forms of energy generation. In addition to reaching cost parity with grid supplied power, a key to the long-term success of PV as a viable energy alternative is the reliability of systems in the field. New technologies may or may not have the same failure modes as previous technologies. Reliability testing and product lifetime issues continue to be one of the key bottlenecks in the rapid commercialization of PV technologies today. In this paper, we highlight the critical need for moving away from relying on traditional qualification and safety tests as a measure of reliability and focus instead on designing for reliability and its integration into the product development process. A drive towards quantitative predictive accelerated testing is emphasized and an industrial collaboration model addressing reliability challenges is proposed.

  15. Development and Reliability Evaluation of the Movement Rating Instrument for Virtual Reality Video Game Play.

    PubMed

    Levac, Danielle; Nawrotek, Joanna; Deschenes, Emilie; Giguere, Tia; Serafin, Julie; Bilodeau, Martin; Sveistrup, Heidi

    2016-06-01

    Virtual reality active video games are increasingly popular physical therapy interventions for children with cerebral palsy. However, physical therapists require educational resources to support decision making about game selection to match individual patient goals. Quantifying the movements elicited during virtual reality active video game play can inform individualized game selection in pediatric rehabilitation. The objectives of this study were to develop and evaluate the feasibility and reliability of the Movement Rating Instrument for Virtual Reality Game Play (MRI-VRGP). Item generation occurred through an iterative process of literature review and sample videotape viewing. The MRI-VRGP includes 25 items quantifying upper extremity, lower extremity, and total body movements. A total of 176 videotaped 90-second game play sessions involving 7 typically developing children and 4 children with cerebral palsy were rated by 3 raters trained in MRI-VRGP use. Children played 8 games on 2 virtual reality and active video game systems. Intraclass correlation coefficients (ICCs) determined intra-rater and interrater reliability. Excellent intrarater reliability was evidenced by ICCs of >0.75 for 17 of the 25 items across the 3 raters. Interrater reliability estimates were less precise. Excellent interrater reliability was achieved for far reach upper extremity movements (ICC=0.92 [for right and ICC=0.90 for left) and for squat (ICC=0.80) and jump items (ICC=0.99), with 9 items achieving ICCs of >0.70, 12 items achieving ICCs of between 0.40 and 0.70, and 4 items achieving poor reliability (close-reach upper extremity-ICC=0.14 for right and ICC=0.07 for left) and single-leg stance (ICC=0.55 for right and ICC=0.27 for left). Poor video quality, differing item interpretations between raters, and difficulty quantifying the high-speed movements involved in game play affected reliability. With item definition clarification and further psychometric property evaluation, the MRI-VRGP could inform the content of educational resources for therapists by ranking games according to frequency and type of elicited body movements.

  16. Ring-like reliable PON planning with physical constraints for a smart grid

    NASA Astrophysics Data System (ADS)

    Wang, Xin; Gu, Rentao; Ji, Yuefeng

    2016-01-01

    Due to the high reliability requirements in the communication networks of a smart grid, a ring-like reliable PON is an ideal choice to carry power distribution information. Economical network planning is also very important for the smart grid communication infrastructure. Although the ring-like reliable PON has been widely used in the real applications, as far as we know, little research has been done on the network optimization subject of the ring-like reliable PON. Most PON planning research studies only consider a star-like topology or cascaded PON network, which barely guarantees the reliability requirements of the smart grid. In this paper, we mainly investigate the economical network planning problem for the ring-like reliable PON of the smart grid. To address this issue, we built a mathematical model for the planning problem of the ring-like reliable PON, and the objective was to minimize the total deployment costs under physical constraints. The model is simplified such that all of the nodes have the same properties, except OLT, because each potential splitter site can be located in the same ONU position in power communication networks. The simplified model is used to construct an optimal main tree topology in the complete graph and a backup-protected tree topology in the residual graph. An efficient heuristic algorithm, called the Constraints and Minimal Weight Oriented Fast Searching Algorithm (CMW-FSA), is proposed. In CMW-FSA, a feasible solution can be obtained directly with oriented constraints and a few recursive search processes. From the simulation results, the proposed planning model and CMW-FSA are verified to be accurate (the error rates are less than 0.4%) and effective compared with the accurate solution (CAESA), especially in small and sparse scenarios. The CMW-FSA significantly reduces the computation time compared with the CAESA. The time complexity algorithm of the CMW-FSA is acceptable and calculated as T(n) = O(n3). After evaluating the effects of the parameters of the two PON systems, the total planning costs of each scenario show a general declining trend and reach a threshold as the respective maximal transmission distances and maximal time delays increase.

  17. Development and Reliability Evaluation of the Movement Rating Instrument for Virtual Reality Video Game Play

    PubMed Central

    Nawrotek, Joanna; Deschenes, Emilie; Giguere, Tia; Serafin, Julie; Bilodeau, Martin; Sveistrup, Heidi

    2016-01-01

    Background Virtual reality active video games are increasingly popular physical therapy interventions for children with cerebral palsy. However, physical therapists require educational resources to support decision making about game selection to match individual patient goals. Quantifying the movements elicited during virtual reality active video game play can inform individualized game selection in pediatric rehabilitation. Objective The objectives of this study were to develop and evaluate the feasibility and reliability of the Movement Rating Instrument for Virtual Reality Game Play (MRI-VRGP). Methods Item generation occurred through an iterative process of literature review and sample videotape viewing. The MRI-VRGP includes 25 items quantifying upper extremity, lower extremity, and total body movements. A total of 176 videotaped 90-second game play sessions involving 7 typically developing children and 4 children with cerebral palsy were rated by 3 raters trained in MRI-VRGP use. Children played 8 games on 2 virtual reality and active video game systems. Intraclass correlation coefficients (ICCs) determined intra-rater and interrater reliability. Results Excellent intrarater reliability was evidenced by ICCs of >0.75 for 17 of the 25 items across the 3 raters. Interrater reliability estimates were less precise. Excellent interrater reliability was achieved for far reach upper extremity movements (ICC=0.92 [for right and ICC=0.90 for left) and for squat (ICC=0.80) and jump items (ICC=0.99), with 9 items achieving ICCs of >0.70, 12 items achieving ICCs of between 0.40 and 0.70, and 4 items achieving poor reliability (close-reach upper extremity-ICC=0.14 for right and ICC=0.07 for left) and single-leg stance (ICC=0.55 for right and ICC=0.27 for left). Conclusions Poor video quality, differing item interpretations between raters, and difficulty quantifying the high-speed movements involved in game play affected reliability. With item definition clarification and further psychometric property evaluation, the MRI-VRGP could inform the content of educational resources for therapists by ranking games according to frequency and type of elicited body movements. PMID:27251029

  18. A Measure for the Reliability of a Rating Scale Based on Longitudinal Clinical Trial Data

    ERIC Educational Resources Information Center

    Laenen, Annouschka; Alonso, Ariel; Molenberghs, Geert

    2007-01-01

    A new measure for reliability of a rating scale is introduced, based on the classical definition of reliability, as the ratio of the true score variance and the total variance. Clinical trial data can be employed to estimate the reliability of the scale in use, whenever repeated measurements are taken. The reliability is estimated from the…

  19. Reliability model generator

    NASA Technical Reports Server (NTRS)

    Cohen, Gerald C. (Inventor); McMann, Catherine M. (Inventor)

    1991-01-01

    An improved method and system for automatically generating reliability models for use with a reliability evaluation tool is described. The reliability model generator of the present invention includes means for storing a plurality of low level reliability models which represent the reliability characteristics for low level system components. In addition, the present invention includes means for defining the interconnection of the low level reliability models via a system architecture description. In accordance with the principles of the present invention, a reliability model for the entire system is automatically generated by aggregating the low level reliability models based on the system architecture description.

  20. Reliability assessments in qualitative health promotion research.

    PubMed

    Cook, Kay E

    2012-03-01

    This article contributes to the debate about the use of reliability assessments in qualitative research in general, and health promotion research in particular. In this article, I examine the use of reliability assessments in qualitative health promotion research in response to health promotion researchers' commonly held misconception that reliability assessments improve the rigor of qualitative research. All qualitative articles published in the journal Health Promotion International from 2003 to 2009 employing reliability assessments were examined. In total, 31.3% (20/64) articles employed some form of reliability assessment. The use of reliability assessments increased over the study period, ranging from <20% in 2003/2004 to 50% and above in 2008/2009, while at the same time the total number of qualitative articles decreased. The articles were then classified into four types of reliability assessments, including the verification of thematic codes, the use of inter-rater reliability statistics, congruence in team coding and congruence in coding across sites. The merits of each type were discussed, with the subsequent discussion focusing on the deductive nature of reliable thematic coding, the limited depth of immediately verifiable data and the usefulness of such studies to health promotion and the advancement of the qualitative paradigm.

  1. Gender differences in diagnosing antisocial personality disorder in methadone patients.

    PubMed

    Rutherford, M J; Alterman, A I; Cacciola, J S; Snider, E C

    1995-09-01

    The goal of this study was to evaluate gender differences in the prevalence rates, short-term reliability, and internal consistency of the diagnosis of antisocial personality disorder for DSM-III-R, DSM-III, and Research Diagnostic Criteria (RDC). A total of 37 men and 57 women methadone patients were diagnosed according to DSM-III-R, DSM-III, and RDC antisocial personality disorder criteria. The diagnostic rates, reliability, and internal consistency were lower for women than for men in all systems. DSM-III criteria resulted in the highest reliability for women, but for men, the DSM-III criteria were the least reliable. Examination of endorsement rates of individual antisocial personality disorder criteria revealed several significant gender differences on the majority of childhood criteria and on several adult criteria. Item-total correlations revealed that for women, the violent and aggressive childhood criteria in DSM-III-R that had not been included in DSM-III or RDC had a negative or no correlation to the assessment of antisocial personality disorder for women. The change in DSM-III-R from DSM-III childhood criteria appears to have resulted in a decrease in internal consistency and rates of antisocial personality disorder for women, but not for men. The results of this investigation indicate that the psychometric properties of the current antisocial personality disorder scales are weak for women, compared with men. To assess antisocial personality disorder in women it may be necessary to revise current, or develop new, diagnostic criteria.

  2. A microRNA detection system based on padlock probes and rolling circle amplification

    PubMed Central

    Jonstrup, Søren Peter; Koch, Jørn; Kjems, Jørgen

    2006-01-01

    The differential expression and the regulatory roles of microRNAs (miRNAs) are being studied intensively these years. Their minute size of only 19–24 nucleotides and strong sequence similarity among related species call for enhanced methods for reliable detection and quantification. Moreover, miRNA expression is generally restricted to a limited number of specific cells within an organism and therefore requires highly sensitive detection methods. Here we present a simple and reliable miRNA detection protocol based on padlock probes and rolling circle amplification. It can be performed without specialized equipment and is capable of measuring the content of specific miRNAs in a few nanograms of total RNA. PMID:16888321

  3. Simple, reliable, and nondestructive method for the measurement of vacuum pressure without specialized equipment.

    PubMed

    Yuan, Jin-Peng; Ji, Zhong-Hua; Zhao, Yan-Ting; Chang, Xue-Fang; Xiao, Lian-Tuan; Jia, Suo-Tang

    2013-09-01

    We present a simple, reliable, and nondestructive method for the measurement of vacuum pressure in a magneto-optical trap. The vacuum pressure is verified to be proportional to the collision rate constant between cold atoms and the background gas with a coefficient k, which can be calculated by means of the simple ideal gas law. The rate constant for loss due to collisions with all background gases can be derived from the total collision loss rate by a series of loading curves of cold atoms under different trapping laser intensities. The presented method is also applicable for other cold atomic systems and meets the miniaturization requirement of commercial applications.

  4. A microRNA detection system based on padlock probes and rolling circle amplification.

    PubMed

    Jonstrup, Søren Peter; Koch, Jørn; Kjems, Jørgen

    2006-09-01

    The differential expression and the regulatory roles of microRNAs (miRNAs) are being studied intensively these years. Their minute size of only 19-24 nucleotides and strong sequence similarity among related species call for enhanced methods for reliable detection and quantification. Moreover, miRNA expression is generally restricted to a limited number of specific cells within an organism and therefore requires highly sensitive detection methods. Here we present a simple and reliable miRNA detection protocol based on padlock probes and rolling circle amplification. It can be performed without specialized equipment and is capable of measuring the content of specific miRNAs in a few nanograms of total RNA.

  5. Development of the hard and soft constraints based optimisation model for unit sizing of the hybrid renewable energy system designed for microgrid applications

    NASA Astrophysics Data System (ADS)

    Sundaramoorthy, Kumaravel

    2017-02-01

    The hybrid energy systems (HESs) based electricity generation system has become a more attractive solution for rural electrification nowadays. Economically feasible and technically reliable HESs are solidly based on an optimisation stage. This article discusses about the optimal unit sizing model with the objective function to minimise the total cost of the HES. Three typical rural sites from southern part of India have been selected for the application of the developed optimisation methodology. Feasibility studies and sensitivity analysis on the optimal HES are discussed elaborately in this article. A comparison has been carried out with the Hybrid Optimization Model for Electric Renewable optimisation model for three sites. The optimal HES is found with less total net present rate and rate of energy compared with the existing method

  6. MALDI-TOF MS Versus VITEK®2: Comparison of Systems for the Identification of Microorganisms Responsible for Bacteremia.

    PubMed

    Febbraro, Filomena; Rodio, Donatella Maria; Puggioni, Gianluca; Antonelli, Guido; Pietropaolo, Valeria; Trancassini, Maria

    2016-12-01

    We evaluated the reliability and accuracy of the combined use of MALDI-TOF MS and classical ID VITEK 2 to identify monomicrobial infection in blood culture bottles. In total, 70 consecutive positive blood cultures were included in this study. Positive blood culture bottles were subjected to Gram staining and subcultured on solid media. Isolates grown from such culture media were used for classical ID using VITEK 2 system. In parallel, an aliquot was subjected to a lysing-centrifugation method and used for the identification with the MALDI-TOF system. Results evidenced the correct genus and species identification of 91.4 % of microorganisms responsible for bacteremia with an agreement to the species and the genus level. If compared with the standard method VITEK 2 , our simple and cost-effective sample preparation method would be very useful for rapid identification of microorganisms using blood culture bottles. In fact, the direct method showed rapid and reliable results, especially for the gram-negative group.

  7. Intra- and extra-articular planes of reference for use in total hip arthroplasty: a preliminary study.

    PubMed

    Hausselle, Jerome; Moreau, Pierre Etienne; Wessely, Loic; de Thomasson, Emmanuel; Assi, Ayman; Parratte, Sebastien; Essig, Jerome; Skalli, Wafa

    2012-08-01

    Acetabular component malalignment in total hip arthroplasty can lead to potential complications such as dislocation, component impingement and excessive wear. Computer-assisted orthopaedic surgery systems generally use the anterior pelvic plane (APP). Our aim was to investigate the reliability of anatomical landmarks accessible during surgery and to define new potential planes of reference. Three types of palpations were performed: virtual, on dry bones and on two cadaveric specimens. Four landmarks were selected, the reproducibility of their positioning ranging from 0.9 to 2.3 mm. We then defined five planes and tested them during palpations on two cadaveric specimens. Two planes produced a mean orientation error of 5.0° [standard deviation (SD 3.3°)] and 5.6° (SD 2.7°). Even if further studies are needed to test the reliability of such planes on a larger scale in vivo during surgery, these results demonstrated the feasibility of defining a new plane of reference as an alternative to the APP.

  8. Drift Reliability Assessment of a Four Storey Frame Residential Building Under Seismic Loading Considering Multiple Factors

    NASA Astrophysics Data System (ADS)

    Sil, Arjun; Longmailai, Thaihamdau

    2017-09-01

    The lateral displacement of Reinforced Concrete (RC) frame building during an earthquake has an important impact on the structural stability and integrity. However, seismic analysis and design of RC building needs more concern due to its complex behavior as the performance of the structure links to the features of the system having many influencing parameters and other inherent uncertainties. The reliability approach takes into account the factors and uncertainty in design influencing the performance or response of the structure in which the safety level or the probability of failure could be ascertained. This present study, aims to assess the reliability of seismic performance of a four storey residential RC building seismically located in Zone-V as per the code provisions given in the Indian Standards IS: 1893-2002. The reliability assessment performed by deriving an explicit expression for maximum roof-lateral displacement as a failure function by regression method. A total of 319, four storey RC buildings were analyzed by linear static method using SAP2000. However, the change in the lateral-roof displacement with the variation of the parameters (column dimension, beam dimension, grade of concrete, floor height and total weight of the structure) was observed. A generalized relation established by regression method which could be used to estimate the expected lateral displacement owing to those selected parameters. A comparison made between the displacements obtained from analysis with that of the equation so formed. However, it shows that the proposed relation could be used directly to determine the expected maximum lateral displacement. The data obtained from the statistical computations was then used to obtain the probability of failure and the reliability.

  9. Reliability of the Client-Centeredness of Goal Setting (C-COGS) Scale in Acquired Brain Injury Rehabilitation.

    PubMed

    Doig, Emmah; Prescott, Sarah; Fleming, Jennifer; Cornwell, Petrea; Kuipers, Pim

    2016-01-01

    To examine the internal reliability and test-retest reliability of the Client-Centeredness of Goal Setting (C-COGS) scale. The C-COGS scale was administered to 42 participants with acquired brain injury after completion of multidisciplinary goal planning. Internal reliability of scale items was examined using item-partial total correlations and Cronbach's α coefficient. The scale was readministered within a 1-mo period to a subsample of 12 participants to examine test-retest reliability by calculating exact and close percentage agreement for each item. After examination of item-partial total correlations, test items were revised. The revised items demonstrated stronger internal consistency than the original items. Preliminary evaluation of test-retest reliability was fair, with an average exact percent agreement across all test items of 67%. Findings support the preliminary reliability of the C-COGS scale as a tool to evaluate and promote client-centered goal planning in brain injury rehabilitation. Copyright © 2016 by the American Occupational Therapy Association, Inc.

  10. The reliability of a segmentation methodology for assessing intramuscular adipose tissue and other soft-tissue compartments of lower leg MRI images.

    PubMed

    Karampatos, Sarah; Papaioannou, Alexandra; Beattie, Karen A; Maly, Monica R; Chan, Adrian; Adachi, Jonathan D; Pritchard, Janet M

    2016-04-01

    Determine the reliability of a magnetic resonance (MR) image segmentation protocol for quantifying intramuscular adipose tissue (IntraMAT), subcutaneous adipose tissue, total muscle and intermuscular adipose tissue (InterMAT) of the lower leg. Ten axial lower leg MRI slices were obtained from 21 postmenopausal women using a 1 Tesla peripheral MRI system. Images were analyzed using sliceOmatic™ software. The average cross-sectional areas of the tissues were computed for the ten slices. Intra-rater and inter-rater reliability were determined and expressed as the standard error of measurement (SEM) (absolute reliability) and intraclass coefficient (ICC) (relative reliability). Intra-rater and inter-rater reliability for IntraMAT were 0.991 (95% confidence interval [CI] 0.978-0.996, p < 0.05) and 0.983 (95% CI 0.958-9.993, p < 0.05), respectively. For the other soft tissue compartments, the ICCs were all >0.90 (p < 0.05). The absolute intra-rater and inter-rater reliability (expressed as SEM) for segmenting IntraMAT were 22.19 mm(2) (95% CI 16.97-32.04) and 78.89 mm(2) (95% CI 60.36-113.92), respectively. This is a reliable segmentation protocol for quantifying IntraMAT and other soft-tissue compartments of the lower leg. A standard operating procedure manual is provided to assist users, and SEM values can be used to estimate sample size and determine confidence in repeated measurements in future research.

  11. The reliability and validity of the Complex Task Performance Assessment: A performance-based assessment of executive function.

    PubMed

    Wolf, Timothy J; Dahl, Abigail; Auen, Colleen; Doherty, Meghan

    2017-07-01

    The objective of this study was to evaluate the inter-rater reliability, test-retest reliability, concurrent validity, and discriminant validity of the Complex Task Performance Assessment (CTPA): an ecologically valid performance-based assessment of executive function. Community control participants (n = 20) and individuals with mild stroke (n = 14) participated in this study. All participants completed the CTPA and a battery of cognitive assessments at initial testing. The control participants completed the CTPA at two different times one week apart. The intra-class correlation coefficient (ICC) for inter-rater reliability for the total score on the CTPA was .991. The ICCs for all of the sub-scores of the CTPA were also high (.889-.977). The CTPA total score was significantly correlated to Condition 4 of the DKEFS Color-Word Interference Test (p = -.425), and the Wechsler Test of Adult Reading (p  = -.493). Finally, there were significant differences between control subjects and individuals with mild stroke on the total score of the CTPA (p = .007) and all sub-scores except interpretation failures and total items incorrect. These results are also consistent with other current executive function performance-based assessments and indicate that the CTPA is a reliable and valid performance-based measure of executive function.

  12. Development and Calibration of an Item Bank for PE Metrics Assessments: Standard 1

    ERIC Educational Resources Information Center

    Zhu, Weimo; Fox, Connie; Park, Youngsik; Fisette, Jennifer L.; Dyson, Ben; Graber, Kim C.; Avery, Marybell; Franck, Marian; Placek, Judith H.; Rink, Judy; Raynes, De

    2011-01-01

    The purpose of this study was to develop and calibrate an assessment system, or bank, using the latest measurement theories and methods to promote valid and reliable student assessment in physical education. Using an anchor-test equating design, a total of 30 items or assessments were administered to 5,021 (2,568 boys and 2,453 girls) students in…

  13. Surfing for mouth guards: assessing quality of online information.

    PubMed

    Magunacelaya, Macarena B; Glendor, Ulf

    2011-10-01

    The Internet is an easily accessible and commonly used source of health-related information, but evaluations of the quality of this information within the dental trauma field are still lacking. The aims of this study are (i) to present the most current scientific knowledge regarding mouth guards used in sport activities, (ii) to suggest a scoring system to evaluate the quality of information pertaining to mouth guard protection related to World Wide Web sites and (iii) to employ this scoring system when seeking reliable mouth guard-related websites. First, an Internet search using the keywords 'athletic injuries/prevention and control' and 'mouth protector' or 'mouth guards' in English was performed on PubMed, Cochrane, SvedMed+ and Web of Science to identify scientific knowledge about mouth guards. Second, an Internet search using the keywords 'consumer health information Internet', 'Internet information public health' and 'web usage-seeking behaviour' was performed on PubMed and Web of Science to obtain scientific articles seeking to evaluate the quality of health information on the Web. Based on the articles found in the second search, two scoring systems were selected. Then, an Internet search using the keywords 'mouth protector', 'mouth guards' and 'gum shields' in English was performed on the search engines Google, MSN and Yahoo. The websites selected were evaluated for reliability and accuracy. Of the 223 websites retrieved, 39 were designated valid and evaluated. Nine sites scored 22 or higher. The mean total score of the 39 websites was 14.2. Fourteen websites scored higher than the mean total score, and 25 websites scored less. The highest total score, presented by a Public Institution Web site (Health Canada), was 31 from a maximum possible score of 34, and the lowest score was 0. This study shows that there is a high amount of information about mouth guards on the Internet but that the quality of this information varies. It should be the responsibility of health care professionals to suggest and provide reliable Internet URL addresses to patients. In addition, an appropriate search terminology and search strategy should be made available to persons who want to search beyond the recommended sites. © 2011 John Wiley & Sons A/S.

  14. Electrochemical disinfection of repeatedly recycled blackwater in a free-standing, additive-free toilet.

    PubMed

    Hawkins, Brian T; Sellgren, Katelyn L; Klem, Ethan J D; Piascik, Jeffrey R; Stoner, Brian R

    2017-11-01

    Decentralized, energy-efficient waste water treatment technologies enabling water reuse are needed to sustainably address sanitation needs in water- and energy-scarce environments. Here, we describe the effects of repeated recycling of disinfected blackwater (as flush liquid) on the energy required to achieve full disinfection with an electrochemical process in a prototype toilet system. The recycled liquid rapidly reached a steady state with total solids reliably ranging between 0.50 and 0.65% and conductivity between 20 and 23 mS/cm through many flush cycles over 15 weeks. The increase in accumulated solids was associated with increased energy demand and wide variation in the free chlorine contact time required to achieve complete disinfection. Further studies on the system at steady state revealed that running at higher voltage modestly improves energy efficiency, and established running parameters that reliably achieve disinfection at fixed run times. These results will guide prototype testing in the field.

  15. [The appraisal of reliability and validity of subjective workload assessment technique and NASA-task load index].

    PubMed

    Xiao, Yuan-mei; Wang, Zhi-ming; Wang, Mian-zhen; Lan, Ya-jia

    2005-06-01

    To test the reliability and validity of two mental workload assessment scales, i.e. subjective workload assessment technique (SWAT) and NASA task load index (NASA-TLX). One thousand two hundred and sixty-eight mental workers were sampled from various kinds of occupations, such as scientific research, education, administration and medicine, etc, with randomized cluster sampling. The re-test reliability, split-half reliability, Cronbach's alpha coefficient and correlation coefficients between item score and total score were adopted to test the reliability. The test of validity included structure validity. The re-test reliability coefficients of these two scales and their items were ranged from 0.516 to 0.753 (P < 0.01), indicating the two scales had good re-test reliability; the split-half reliability of SWAT was 0.645, and its Cronbach's alpha coefficient was more than 0.80, all the correlation coefficients between its items score and total score were more than 0.70; as for NASA-TLX, both the split-half reliability and Cronbach's alpha coefficient were more than 0.80, the correlation coefficients between its items score and total score were all more than 0.60 (P < 0.01) except the item of performance. Both scales had good inner consistency. The Pearson correlation coefficient between the two scales was 0.492 (P < 0.01), implying the results of the two scales had good consistency. Factor analysis showed that the two scales had good structure validity. Both SWAT and NASA-TLX have good reliability and validity and may be used as a valid tool to assess mental workload in China after being revised properly.

  16. Testing the Difference between Reliability Coefficients Alpha and Omega

    ERIC Educational Resources Information Center

    Deng, Lifang; Chan, Wai

    2017-01-01

    Reliable measurements are key to social science research. Multiple measures of reliability of the total score have been developed, including coefficient alpha, coefficient omega, the greatest lower bound reliability, and others. Among these, the coefficient alpha has been most widely used, and it is reported in nearly every study involving the…

  17. Bearing Procurement Analysis Method by Total Cost of Ownership Analysis and Reliability Prediction

    NASA Astrophysics Data System (ADS)

    Trusaji, Wildan; Akbar, Muhammad; Sukoyo; Irianto, Dradjad

    2018-03-01

    In making bearing procurement analysis, price and its reliability must be considered as decision criteria, since price determines the direct cost as acquisition cost and reliability of bearing determine the indirect cost such as maintenance cost. Despite the indirect cost is hard to identify and measured, it has high contribution to overall cost that will be incurred. So, the indirect cost of reliability must be considered when making bearing procurement analysis. This paper tries to explain bearing evaluation method with the total cost of ownership analysis to consider price and maintenance cost as decision criteria. Furthermore, since there is a lack of failure data when bearing evaluation phase is conducted, reliability prediction method is used to predict bearing reliability from its dynamic load rating parameter. With this method, bearing with a higher price but has higher reliability is preferable for long-term planning. But for short-term planning the cheaper one but has lower reliability is preferable. This contextuality can give rise to conflict between stakeholders. Thus, the planning horizon needs to be agreed by all stakeholder before making a procurement decision.

  18. Online Condition Monitoring of Bearings to Support Total Productive Maintenance in the Packaging Materials Industry.

    PubMed

    Gligorijevic, Jovan; Gajic, Dragoljub; Brkovic, Aleksandar; Savic-Gajic, Ivana; Georgieva, Olga; Di Gennaro, Stefano

    2016-03-01

    The packaging materials industry has already recognized the importance of Total Productive Maintenance as a system of proactive techniques for improving equipment reliability. Bearing faults, which often occur gradually, represent one of the foremost causes of failures in the industry. Therefore, detection of their faults in an early stage is quite important to assure reliable and efficient operation. We present a new automated technique for early fault detection and diagnosis in rolling-element bearings based on vibration signal analysis. Following the wavelet decomposition of vibration signals into a few sub-bands of interest, the standard deviation of obtained wavelet coefficients is extracted as a representative feature. Then, the feature space dimension is optimally reduced to two using scatter matrices. In the reduced two-dimensional feature space the fault detection and diagnosis is carried out by quadratic classifiers. Accuracy of the technique has been tested on four classes of the recorded vibrations signals, i.e., normal, with the fault of inner race, outer race, and ball operation. The overall accuracy of 98.9% has been achieved. The new technique can be used to support maintenance decision-making processes and, thus, to increase reliability and efficiency in the industry by preventing unexpected faulty operation of bearings.

  19. Online Condition Monitoring of Bearings to Support Total Productive Maintenance in the Packaging Materials Industry

    PubMed Central

    Gligorijevic, Jovan; Gajic, Dragoljub; Brkovic, Aleksandar; Savic-Gajic, Ivana; Georgieva, Olga; Di Gennaro, Stefano

    2016-01-01

    The packaging materials industry has already recognized the importance of Total Productive Maintenance as a system of proactive techniques for improving equipment reliability. Bearing faults, which often occur gradually, represent one of the foremost causes of failures in the industry. Therefore, detection of their faults in an early stage is quite important to assure reliable and efficient operation. We present a new automated technique for early fault detection and diagnosis in rolling-element bearings based on vibration signal analysis. Following the wavelet decomposition of vibration signals into a few sub-bands of interest, the standard deviation of obtained wavelet coefficients is extracted as a representative feature. Then, the feature space dimension is optimally reduced to two using scatter matrices. In the reduced two-dimensional feature space the fault detection and diagnosis is carried out by quadratic classifiers. Accuracy of the technique has been tested on four classes of the recorded vibrations signals, i.e., normal, with the fault of inner race, outer race, and ball operation. The overall accuracy of 98.9% has been achieved. The new technique can be used to support maintenance decision-making processes and, thus, to increase reliability and efficiency in the industry by preventing unexpected faulty operation of bearings. PMID:26938541

  20. Reliability Evaluation and Improvement Approach of Chemical Production Man - Machine - Environment System

    NASA Astrophysics Data System (ADS)

    Miao, Yongchun; Kang, Rongxue; Chen, Xuefeng

    2017-12-01

    In recent years, with the gradual extension of reliability research, the study of production system reliability has become the hot topic in various industries. Man-machine-environment system is a complex system composed of human factors, machinery equipment and environment. The reliability of individual factor must be analyzed in order to gradually transit to the research of three-factor reliability. Meanwhile, the dynamic relationship among man-machine-environment should be considered to establish an effective blurry evaluation mechanism to truly and effectively analyze the reliability of such systems. In this paper, based on the system engineering, fuzzy theory, reliability theory, human error, environmental impact and machinery equipment failure theory, the reliabilities of human factor, machinery equipment and environment of some chemical production system were studied by the method of fuzzy evaluation. At last, the reliability of man-machine-environment system was calculated to obtain the weighted result, which indicated that the reliability value of this chemical production system was 86.29. Through the given evaluation domain it can be seen that the reliability of man-machine-environment integrated system is in a good status, and the effective measures for further improvement were proposed according to the fuzzy calculation results.

  1. A Ground-Based Comparison of the Muscle Atrophy Research and Exercise System (MARES) and a Standard Isokinetic Dynamometer

    NASA Technical Reports Server (NTRS)

    Hackney, K. J.; English, K. L.; Redd, E.; DeWitt, J. K.; Ploutz-Snyder, R.; Ploutz-Snyder, L. L.

    2010-01-01

    PURPOSE: 1) To compare the test-to-test reliability of Muscle Atrophy Research and Exercise System (MARES) with a standard laboratory isokinetic dynamometer (ISOK DYN) and; 2) to determine if measures of peak torque and total work differ between devices. METHODS: Ten subjects (6M, 4F) completed two trials on both MARES and an ISOK DYN in a counterbalanced order. Peak torque values at 60 deg & 180 deg / s were obtained from five maximal repetitions of knee extension (KE) and knee flexion (KF). Total work at 180 deg / s was determined from the area under the torque vs. displacement curve during twenty maximal repetitions of KE and KF. Reliability of measures within devices was interpreted from the intraclass correlation coefficient (ICC) and compared between devices using the ratio of the within-device standard deviations. Indicators of agreement for the two devices were evaluated from: 1) a calculation of concordance (rho) and; 2) the correlation between the mean of measures versus the delta difference between measures (m u vs delta). RESULTS: For all outcome measures ICCs were high for both the ISOK DYN (0.95-0.99) and MARES (0.90-0.99). However, ratios of the within-device standard deviation were 1.3 to 4.3 times higher on MARES. On average, a wide range (3.3 to 1054 Nm) of differences existed between the values obtained. Only KE peak torque measured at 60 deg & 180 deg / s showed similarities between devices (rho = 0.91 & 0.87; Pearson's r for m u vs delta = -0.22 & -0.37, respectively). CONCLUSION: Although MARES was designed for use in microgravity it was quite reliable during ground-based testing. However, MARES was consistently more variable than an ISOK DYN. Future longitudinal studies evaluating a change in isokinetic peak torque or total work should be limited within one device.

  2. Modeling and simulation of reliability of unmanned intelligent vehicles

    NASA Astrophysics Data System (ADS)

    Singh, Harpreet; Dixit, Arati M.; Mustapha, Adam; Singh, Kuldip; Aggarwal, K. K.; Gerhart, Grant R.

    2008-04-01

    Unmanned ground vehicles have a large number of scientific, military and commercial applications. A convoy of such vehicles can have collaboration and coordination. For the movement of such a convoy, it is important to predict the reliability of the system. A number of approaches are available in literature which describes the techniques for determining the reliability of the system. Graph theoretic approaches are popular in determining terminal reliability and system reliability. In this paper we propose to exploit Fuzzy and Neuro-Fuzzy approaches for predicting the node and branch reliability of the system while Boolean algebra approaches are used to determine terminal reliability and system reliability. Hence a combination of intelligent approaches like Fuzzy, Neuro-Fuzzy and Boolean approaches is used to predict the overall system reliability of a convoy of vehicles. The node reliabilities may correspond to the collaboration of vehicles while branch reliabilities will determine the terminal reliabilities between different nodes. An algorithm is proposed for determining the system reliabilities of a convoy of vehicles. The simulation of the overall system is proposed. Such simulation should be helpful to the commander to take an appropriate action depending on the predicted reliability in different terrain and environmental conditions. It is hoped that results of this paper will lead to more important techniques to have a reliable convoy of vehicles in a battlefield.

  3. An integrated exhaust gas analysis system with self-contained data processing and automatic calibration

    NASA Technical Reports Server (NTRS)

    Anderson, R. C.; Summers, R. L.

    1981-01-01

    An integrated gas analysis system designed to operate in automatic, semiautomatic, and manual modes from a remote control panel is described. The system measures the carbon monoxide, oxygen, water vapor, total hydrocarbons, carbon dioxide, and oxides of nitrogen. A pull through design provides increased reliability and eliminates the need for manual flow rate adjustment and pressure correction. The system contains two microprocessors to range the analyzers, calibrate the system, process the raw data to units of concentration, and provides information to the facility research computer and to the operator through terminal and the control panels. After initial setup, the system operates for several hours without significant operator attention.

  4. Applicability and Limitations of Reliability Allocation Methods

    NASA Technical Reports Server (NTRS)

    Cruz, Jose A.

    2016-01-01

    Reliability allocation process may be described as the process of assigning reliability requirements to individual components within a system to attain the specified system reliability. For large systems, the allocation process is often performed at different stages of system design. The allocation process often begins at the conceptual stage. As the system design develops, more information about components and the operating environment becomes available, different allocation methods can be considered. Reliability allocation methods are usually divided into two categories: weighting factors and optimal reliability allocation. When properly applied, these methods can produce reasonable approximations. Reliability allocation techniques have limitations and implied assumptions that need to be understood by system engineers. Applying reliability allocation techniques without understanding their limitations and assumptions can produce unrealistic results. This report addresses weighting factors, optimal reliability allocation techniques, and identifies the applicability and limitations of each reliability allocation technique.

  5. Reliability and coverage analysis of non-repairable fault-tolerant memory systems

    NASA Technical Reports Server (NTRS)

    Cox, G. W.; Carroll, B. D.

    1976-01-01

    A method was developed for the construction of probabilistic state-space models for nonrepairable systems. Models were developed for several systems which achieved reliability improvement by means of error-coding, modularized sparing, massive replication and other fault-tolerant techniques. From the models developed, sets of reliability and coverage equations for the systems were developed. Comparative analyses of the systems were performed using these equation sets. In addition, the effects of varying subunit reliabilities on system reliability and coverage were described. The results of these analyses indicated that a significant gain in system reliability may be achieved by use of combinations of modularized sparing, error coding, and software error control. For sufficiently reliable system subunits, this gain may far exceed the reliability gain achieved by use of massive replication techniques, yet result in a considerable saving in system cost.

  6. Validity and reliability of a novel immunosuppressive adverse effects scoring system in renal transplant recipients.

    PubMed

    Meaney, Calvin J; Arabi, Ziad; Venuto, Rocco C; Consiglio, Joseph D; Wilding, Gregory E; Tornatore, Kathleen M

    2014-06-12

    After renal transplantation, many patients experience adverse effects from maintenance immunosuppressive drugs. When these adverse effects occur, patient adherence with immunosuppression may be reduced and impact allograft survival. If these adverse effects could be prospectively monitored in an objective manner and possibly prevented, adherence to immunosuppressive regimens could be optimized and allograft survival improved. Prospective, standardized clinical approaches to assess immunosuppressive adverse effects by health care providers are limited. Therefore, we developed and evaluated the application, reliability and validity of a novel adverse effects scoring system in renal transplant recipients receiving calcineurin inhibitor (cyclosporine or tacrolimus) and mycophenolic acid based immunosuppressive therapy. The scoring system included 18 non-renal adverse effects organized into gastrointestinal, central nervous system and aesthetic domains developed by a multidisciplinary physician group. Nephrologists employed this standardized adverse effect evaluation in stable renal transplant patients using physical exam, review of systems, recent laboratory results, and medication adherence assessment during a clinic visit. Stable renal transplant recipients in two clinical studies were evaluated and received immunosuppressive regimens comprised of either cyclosporine or tacrolimus with mycophenolic acid. Face, content, and construct validity were assessed to document these adverse effect evaluations. Inter-rater reliability was determined using the Kappa statistic and intra-class correlation. A total of 58 renal transplant recipients were assessed using the adverse effects scoring system confirming face validity. Nephrologists (subject matter experts) rated the 18 adverse effects as: 3.1 ± 0.75 out of 4 (maximum) regarding clinical importance to verify content validity. The adverse effects scoring system distinguished 1.75-fold increased gastrointestinal adverse effects (p=0.008) in renal transplant recipients receiving tacrolimus and mycophenolic acid compared to the cyclosporine regimen. This finding demonstrated construct validity. Intra-class correlation was 0.81 (95% confidence interval: 0.65-0.90) and Kappa statistic of 0.68 ± 0.25 for all 18 adverse effects and verified substantial inter-rater reliability. This immunosuppressive adverse effects scoring system in stable renal transplant recipients was evaluated and substantiated face, content and construct validity with inter-rater reliability. The scoring system may facilitate prospective, standardized clinical monitoring of immunosuppressive adverse drug effects in stable renal transplant recipients and improve medication adherence.

  7. Test-retest reliability and minimal detectable change of two simplified 3-point balance measures in patients with stroke.

    PubMed

    Chen, Yi-Miau; Huang, Yi-Jing; Huang, Chien-Yu; Lin, Gong-Hong; Liaw, Lih-Jiun; Lee, Shih-Chieh; Hsieh, Ching-Lin

    2017-10-01

    The 3-point Berg Balance Scale (BBS-3P) and 3-point Postural Assessment Scale for Stroke Patients (PASS-3P) were simplified from the BBS and PASS to overcome the complex scoring systems. The BBS-3P and PASS-3P were more feasible in busy clinical practice and showed similarly sound validity and responsiveness to the original measures. However, the reliability of the BBS-3P and PASS-3P is unknown limiting their utility and the interpretability of scores. We aimed to examine the test-retest reliability and minimal detectable change (MDC) of the BBS-3P and PASS-3P in patients with stroke. Cross-sectional study. The rehabilitation departments of a medical center and a community hospital. A total of 51 chronic stroke patients (64.7% male). Both balance measures were administered twice 7 days apart. The test-retest reliability of both the BBS-3P and PASS-3P were examined by intraclass correlation coefficients (ICC). The MDC and its percentage over the total score (MDC%) of each measure was calculated for examining the random measurement errors. The ICC values of the BBS-3P and PASS-3P were 0.99 and 0.97, respectively. The MDC% (MDC) of the BBS-3P and PASS-3P were 9.1% (5.1 points) and 8.4% (3.0 points), respectively, indicating that both measures had small and acceptable random measurement errors. Our results showed that both the BBS-3P and the PASS-3P had good test-retest reliability, with small and acceptable random measurement error. These two simplified 3-level balance measures can provide reliable results over time. Our findings support the repeated administration of the BBS-3P and PASS-3P to monitor the balance of patients with stroke. The MDC values can help clinicians and researchers interpret the change scores more precisely.

  8. Validity and reliability of the infant breastfeeding assessment tool, the mother baby assessment tool, and the LATCH scoring system.

    PubMed

    Altuntas, Nilgun; Turkyilmaz, Canan; Yildiz, Havva; Kulali, Ferit; Hirfanoglu, Ibrahim; Onal, Esra; Ergenekon, Ebru; Koç, Esin; Atalay, Yıldız

    2014-05-01

    We aimed to evaluate the validity and reliability of the Infant Breastfeeding Assessment Tool (IBFAT), the Mother Baby Assessment (MBA) Tool, and the LATCH scoring system. Mothers who delivered healthy, full-term infants in the Obstetrics & Gynecology Service of Gazi University, Ankara, Turkey, between December 2013 and January 2014 and their infants were included in the study. Forty-six randomly selected breastfeeding sessions were monitored and scored simultaneously by three researchers (Raters 1, 2, and 3) using LATCH, IBFAT, and the MBA Tool. Researchers put the score sheets in an envelope in order to hide them from each other. The compatibility of the scores given by three researchers was assessed by statistical methods. We found positive and significant correlation coefficients between 0.81 to 0.88 for the total MBA score, between 0.90 to 0.95 for the total IBFAT score, and between 0.85 to 0.91 for the total LATCH score. Correlation coefficients testing these three tools ranged from 0.71 to 0.88, with the minimum value being noted for the correlation between LATCH and IBFAT scores and the maximum value being noted for the correlation between LATCH and MBA scores. We found positive and significant correlations between researchers' scores for 46 observations using the three assessment tools. This study showed that these above-mentioned tools were compatible for the assessment of the efficiency of breastfeeding.

  9. Photovoltaic-system evaluation at the Northeast Residential Experiment Station

    NASA Astrophysics Data System (ADS)

    Russell, M. C.

    1983-01-01

    Five residential photovoltaic systems were tested and the systems' performance and cost was evaluated. The five systems each consist of an unoccupied structure employing a roof mounted photovoltaic array and a utility connected power inverter capable of sending excess PV generated energy to the local utility system. The photovoltaic systems are designed to meet at least 50% of the total annual electrical demand of residences in the cold climate regions of the country. The following specific issues were investigated: photovoltaic array and inverter system power rating and performance characterization, system energy production, reliability and system cost/worth. Summary load data from five houses in the vicinity of the Northeast Residential Experiment Station, and meteorological data from the station's weather station are also presented.

  10. Implementing supercritical water oxidation technology in a lunar base environmental control/life support system

    NASA Technical Reports Server (NTRS)

    Meyer Sedej, M.

    1985-01-01

    A supercritical water oxidation system (SCWOS) offers several advantages for a lunar base environmental control/life support system (ECLSS) compared to an ECLSS based on Space Station technology. In supercritically heated water (630 K, 250 atm) organic materials mix freely with oxygen and undergo complete combustion. Inorganic salts lose solubility and precipitate out. Implementation of SCWOS can make an ECLSS more efficient and reliable by elimination of several subsystems and by reduction in potential losses of life support consumables. More complete closure of the total system reduces resupply requirements from the earth, a crucial cost item in maintaining a lunar base.

  11. Development and Validation of a Portable and Inexpensive Tool to Measure the Drop Vertical Jump Using the Microsoft Kinect V2.

    PubMed

    Gray, Aaron D; Willis, Brad W; Skubic, Marjorie; Huo, Zhiyu; Razu, Swithin; Sherman, Seth L; Guess, Trent M; Jahandar, Amirhossein; Gulbrandsen, Trevor R; Miller, Scott; Siesener, Nathan J

    Noncontact anterior cruciate ligament (ACL) injury in adolescent female athletes is an increasing problem. The knee-ankle separation ratio (KASR), calculated at initial contact (IC) and peak flexion (PF) during the drop vertical jump (DVJ), is a measure of dynamic knee valgus. The Microsoft Kinect V2 has shown promise as a reliable and valid marker-less motion capture device. The Kinect V2 will demonstrate good to excellent correlation between KASR results at IC and PF during the DVJ, as compared with a "gold standard" Vicon motion analysis system. Descriptive laboratory study. Level 2. Thirty-eight healthy volunteer subjects (20 male, 18 female) performed 5 DVJ trials, simultaneously measured by a Vicon MX-T40S system, 2 AMTI force platforms, and a Kinect V2 with customized software. A total of 190 jumps were completed. The KASR was calculated at IC and PF during the DVJ. The intraclass correlation coefficient (ICC) assessed the degree of KASR agreement between the Kinect and Vicon systems. The ICCs of the Kinect V2 and Vicon KASR at IC and PF were 0.84 and 0.95, respectively, showing excellent agreement between the 2 measures. The Kinect V2 successfully identified the KASR at PF and IC frames in 182 of 190 trials, demonstrating 95.8% reliability. The Kinect V2 demonstrated excellent ICC of the KASR at IC and PF during the DVJ when compared with the Vicon system. A customized Kinect V2 software program demonstrated good reliability in identifying the KASR at IC and PF during the DVJ. Reliable, valid, inexpensive, and efficient screening tools may improve the accessibility of motion analysis assessment of adolescent female athletes.

  12. [Fatal occupational accidents: estimates based on more data sources].

    PubMed

    Baldasseroni, A; Chellini, E; Zoppi, O; Giovannetti, L

    2001-01-01

    The data reported by INAIL (Istituto Nazionale Assicurazione Infortuni sul Lavoro) on fatal occupational injuries have always been considered complete and reliable. The authors of this article verified the completeness of this information source crossing it with data bases existing in different registration systems (Regional Mortality Registry of Tuscany--RMR; registers and data of the Operative Units of Prevention, Hygiene and Safety in the Workplace--UOPISLL) for the period between 1992 and 1996. In the five years concerned, a total of 458 cases were reported. These cases could be considered fatal injuries at work without taking into account traffic accidents, which were not included in the present study. The results show that the most complete information source was RMR, reporting 80% of the total data, while INAIL reports only 62.2% of the total cases. On the contrary, the UOPISLL source is the least reliable. Using the capture/recapture method, the estimate of events in the period concerned (1992-1996) amounts to nearly 500 (499.8 LC 475.9-523.7), while the three sources systematically explored for the whole period (INAIL, RMR, UOSPILL) report 458 cases. An additional information source, the daily press, which could be systematically tested only two months for each of the five years, reports 10 additional cases, which were ignored by the 3 other sources, indirectly confirming in this way how reliable the performed estimate was. The main cases among the 157 fatal accidents reported by RMR, but not by INAIL, occurred among farmers (70), most of them already retired, but there were several fatal accidents reported in the construction sector (30). Other categories were included only in the RMR data because, in the period concerned, they were not covered by INAIL insurance (18 cases in the Army and Police, 7 on the railways). The survey that was carried out confirms the essential importance of INAIL data for the surveillance system applied to this phenomenon. This also confirms the need--which has been already stressed in the scientific literature--to combine INAIL's registration system at least with the mortality registries. In this way the knowledge and comprehension of the phenomenon could be integrated and completed especially for marginal work areas, where obligatory insurance may be evaded; and for groups of workers not covered by insurance. The relevance of an integrated system of registration of occupational fatal accidents is discussed.

  13. Development and first validation of a simplified CT-based classification system of soft tissue changes in large-head metal-on-metal total hip replacement: intra- and interrater reliability and association with revision rates in a uniform cohort of 664 arthroplasties.

    PubMed

    Boomsma, Martijn F; Edens, Mireille A; Van Lingen, Christiaan P; Warringa, Niek; Ettema, Harmen B; Verheyen, Cees C P M; Maas, Mario

    2015-08-01

    After implantation of a metal-on-metal total hip arthroplasty (MoM THA), a large incidence of pseudotumor formation has been described recently. Several centers have invited patients for follow-up in order to screen for pseudotumor formation. The spectrum of abnormalities found by CT in MoM THA patients can be unfamiliar to radiologists and orthopedic surgeons. Previously, a CT five-point grading scale has been published. In this paper, a simplification into a three-point classification system gives insight in the morphological distinction of abnormalities of the postoperative hip capsule in MoM implants in relation to the decision for revision. The reliability of this simplified classification regarding intra- and interrater reliability and its association with revision rate is investigated and discussed. All patients who underwent MoM THA in our hospital were invited for screening. Various clinical measures and CT scan were obtained in a cross-sectional fashion. A decision on revision surgery was made shortly after screening. CT scans were read in 582 patients, of which 82 patients were treated bilaterally. CT scans were independently single read by two board-certified radiologists and classified into categories I-V. In a second meeting, consensus was obtained. Categories were subsequently rubricated in class A (categories I and II), B (category III), and C (categories IV and V). Intra- and inter-radiologist agreement on MoM pathology was assessed by means of the weighted Cohen's kappa. Categorical data were presented as n (%), and tested by means of Fisher's exact test. Continuous data were presented as median (min-max) and tested by means of Mann-Whitney U test (two group comparison) or Kruskal-Wallis test (three group comparison). Logistic regression analysis was performed in order to study independence of CT class for association with revision surgery. Univariate statistically significant variables were entered in a multiple model. All statistical analysis was performed two-tailed using alpha 5% as the significance level. In total, 664 scores from 664 MoM hips obtained by two observers were available for analyses. Interobserver reliability for the non-simplified version (I-V) was κw = 0.71 (95% CI: 0.62-0.79), which indicates good agreement between the two musculoskeletal radiologists. Intra- and interobserver reliability for the simplified version (A-C) were respectively κw 0.78 (95% CI: 0.68-0.87), and κw = 0.71 (95% CI: 0.65-0.76). This indicates good agreement within and between the two observers. The simplified A-C version is significantly associated with revision exclusively due to MoM pathology, in both patients with unilateral MoM THA (p < 0.001) and patients with bilateral MoM THA (p < 0.044). The simplified A-C version is associated with several clinical measures. In patients with unilateral MoM THA, with or without contralateral THA, in situ time (p < 0.008), cobalt and chromium (p < 0.001) were statistically significant. In patients with bilateral MoM, cobalt (p < 0.001) and chromium (p < 0.027) were statistically significant. Revision is significantly associated with cup size (p < 0.001), anteversion of the cup (p < 0.004), serum ion levels of cobalt and chromium (p < 0.001) and the adapted classification system (p < 0.001). In univariate logistic regression analysis on revision, cup, anteversion of the cup, cobalt-chromium ion serum levels, and the simplified (A-C) CT category system were statistically significant. The simplified (A-C) CT category system was an independent associate of revision, in several multiple logistic regression models. The presented simplified CT grading system (A-C) in its first clinical validation on 48- and 64-multislice systems is reliable, showing good intra- and interrater reliability and is independently associated with revision surgery.

  14. The Reliability of a Three-Dimensional Photo System- (3dMDface-) Based Evaluation of the Face in Cleft Lip Infants

    PubMed Central

    Ort, Rebecca; Metzler, Philipp; Kruse, Astrid L.; Matthews, Felix; Zemann, Wolfgang; Grätz, Klaus W.; Luebbers, Heinz-Theo

    2012-01-01

    Ample data exists about the high precision of three-dimensional (3D) scanning devices and their data acquisition of the facial surface. However, a question remains regarding which facial landmarks are reliable if identified in 3D images taken under clinical circumstances. Sources of error to be addressed could be technical, user dependent, or patient respectively anatomy related. Based on clinical 3D photos taken with the 3dMDface system, the intra observer repeatability of 27 facial landmarks in six cleft lip (CL) infants and one non-CL infant was evaluated based on a total of over 1,100 measurements. Data acquisition was sometimes challenging but successful in all patients. The mean error was 0.86 mm, with a range of 0.39 mm (Exocanthion) to 2.21 mm (soft gonion). Typically, landmarks provided a small mean error but still showed quite a high variance in measurements, for example, exocanthion from 0.04 mm to 0.93 mm. Vice versa, relatively imprecise landmarks still provide accurate data regarding specific spatial planes. One must be aware of the fact that the degree of precision is dependent on landmarks and spatial planes in question. In clinical investigations, the degree of reliability for landmarks evaluated should be taken into account. Additional reliability can be achieved via multiple measuring. PMID:22919476

  15. A cost assessment of reliability requirements for shuttle-recoverable experiments

    NASA Technical Reports Server (NTRS)

    Campbell, J. W.

    1975-01-01

    The relaunching of unsuccessful experiments or satellites will become a real option with the advent of the space shuttle. An examination was made of the cost effectiveness of relaxing reliability requirements for experiment hardware by allowing more than one flight of an experiment in the event of its failure. Any desired overall reliability or probability of mission success can be acquired by launching an experiment with less reliability two or more times if necessary. Although this procedure leads to uncertainty in total cost projections, because the number of flights is not known in advance, a considerable cost reduction can sometimes be achieved. In cases where reflight costs are low relative to the experiment's cost, three flights with overall reliability 0.9 can be made for less than half the cost of one flight with a reliability of 0.9. An example typical of shuttle payload cost projections is cited where three low reliability flights would cost less than $50 million and a single high reliability flight would cost over $100 million. The ratio of reflight cost to experiment cost is varied and its effect on the range in total cost is observed. An optimum design reliability selection criterion to minimize expected cost is proposed, and a simple graphical method of determining this reliability is demonstrated.

  16. Experimental investigation of evanescence-based infrared biodetection technique for micro-total-analysis systems.

    PubMed

    Chandrasekaran, Arvind; Packirisamy, Muthukumaran

    2009-01-01

    The advent of microoptoelectromechanical systems (MOEMS) and its integration with other technologies such as microfluidics, microthermal, immunoproteomics, etc. has led to the concept of an integrated micro-total-analysis systems (microTAS) or Lab-on-a-Chip for chemical and biological applications. Recently, research and development of microTAS have attained a significant growth rate over several biodetection sciences, in situ medical diagnoses, and point-of-care testing applications. However, it is essential to develop suitable biophysical label-free detection methods for the success, reliability, and ease of use of the microTAS. We proposed an infrared (IR)-based evanescence wave detection system on the silicon-on-insulator platform for biodetection with microTAS. The system operates on the principle of bio-optical interaction that occurs due to the evanescence of light from the waveguide device. The feasibility of biodetection has been experimentally investigated by the detection of horse radish peroxidase upon its reaction with hydrogen peroxide.

  17. Reliability and validity of the McDonald Play Inventory.

    PubMed

    McDonald, Ann E; Vigen, Cheryl

    2012-01-01

    This study examined the ability of a two-part self-report instrument, the McDonald Play Inventory, to reliably and validly measure the play activities and play styles of 7- to 11-yr-old children and to discriminate between the play of neurotypical children and children with known learning and developmental disabilities. A total of 124 children ages 7-11 recruited from a sample of convenience and a subsample of 17 parents participated in this study. Reliability estimates yielded moderate correlations for internal consistency, total test intercorrelations, and test-retest reliability. Validity estimates were established for content and construct validity. The results suggest that a self-report instrument yields reliable and valid measures of a child's perceived play performance and discriminates between the play of children with and without disabilities. Copyright © 2012 by the American Occupational Therapy Association, Inc.

  18. Estimating the Reliability of a Test Battery Composite or a Test Score Based on Weighted Item Scoring

    ERIC Educational Resources Information Center

    Feldt, Leonard S.

    2004-01-01

    In some settings, the validity of a battery composite or a test score is enhanced by weighting some parts or items more heavily than others in the total score. This article describes methods of estimating the total score reliability coefficient when differential weights are used with items or parts.

  19. Development, scoring, and reliability of the Microscale Audit of Pedestrian Streetscapes (MAPS)

    PubMed Central

    2013-01-01

    Background Streetscape (microscale) features of the built environment can influence people’s perceptions of their neighborhoods’ suitability for physical activity. Many microscale audit tools have been developed, but few have published systematic scoring methods. We present the development, scoring, and reliability of the Microscale Audit of Pedestrian Streetscapes (MAPS) tool and its theoretically-based subscales. Methods MAPS was based on prior instruments and was developed to assess details of streetscapes considered relevant for physical activity. MAPS sections (route, segments, crossings, and cul-de-sacs) were scored by two independent raters for reliability analyses. There were 290 route pairs, 516 segment pairs, 319 crossing pairs, and 53 cul-de-sac pairs in the reliability sample. Individual inter-rater item reliability analyses were computed using Kappa, intra-class correlation coefficient (ICC), and percent agreement. A conceptual framework for subscale creation was developed using theory, expert consensus, and policy relevance. Items were grouped into subscales, and subscales were analyzed for inter-rater reliability at tiered levels of aggregation. Results There were 160 items included in the subscales (out of 201 items total). Of those included in the subscales, 80 items (50.0%) had good/excellent reliability, 41 items (25.6%) had moderate reliability, and 18 items (11.3%) had low reliability, with limited variability in the remaining 21 items (13.1%). Seventeen of the 20 route section subscales, valence (positive/negative) scores, and overall scores (85.0%) demonstrated good/excellent reliability and 3 demonstrated moderate reliability. Of the 16 segment subscales, valence scores, and overall scores, 12 (75.0%) demonstrated good/excellent reliability, three demonstrated moderate reliability, and one demonstrated poor reliability. Of the 8 crossing subscales, valence scores, and overall scores, 6 (75.0%) demonstrated good/excellent reliability, and 2 demonstrated moderate reliability. The cul-de-sac subscale demonstrated good/excellent reliability. Conclusions MAPS items and subscales predominantly demonstrated moderate to excellent reliability. The subscales and scoring system represent a theoretically based framework for using these complex microscale data and may be applicable to other similar instruments. PMID:23621947

  20. A particle swarm model for estimating reliability and scheduling system maintenance

    NASA Astrophysics Data System (ADS)

    Puzis, Rami; Shirtz, Dov; Elovici, Yuval

    2016-05-01

    Modifying data and information system components may introduce new errors and deteriorate the reliability of the system. Reliability can be efficiently regained with reliability centred maintenance, which requires reliability estimation for maintenance scheduling. A variant of the particle swarm model is used to estimate reliability of systems implemented according to the model view controller paradigm. Simulations based on data collected from an online system of a large financial institute are used to compare three component-level maintenance policies. Results show that appropriately scheduled component-level maintenance greatly reduces the cost of upholding an acceptable level of reliability by reducing the need in system-wide maintenance.

  1. Space nuclear power applied to electric propulsion

    NASA Technical Reports Server (NTRS)

    Vicente, F. A.; Karras, T.; Darooka, D.; Isenberg, L.

    1989-01-01

    Space reactor power systems with characteristics ideal for advanced spacecraft systems applications are discussed. These characteristics are: high power-to-weight ratio (15 to 33 W/kg); high volume density (high ballistic coefficient); no preferential orientation in orbit; long operational life; high reliability; and total launch and operational safety. These characteristics allow the use of electric propulsion to raise spacecraft from low earth parking orbits to operational orbits, greatly increasing the useful orbit payload for a given launch vehicle by eliminating the need for a separation injection stage. A proposed demonstration mission is described.

  2. Cerebral laterality and verbal processes.

    PubMed

    Sherman, J L; Kulhavy, R W; Burns, K

    1976-11-01

    Research suggests that we process information by way of two distinct and functionallly separate coding systems. The localization of these two processing systems appears to be somewhat dependent on cerebral laterality, which has been shown to vary in right-handed and left-handed persons. To test the dual coding model, right-handed and left-handed subjects learned lists of abstract and concrete words under various conditions of visual and tactile interference. Right-handed subjects showed a significant superiority in the remembering of highly concrete items, while total recall did not differ reliably between groups.

  3. Flat conductor cable for electrical packaging

    NASA Technical Reports Server (NTRS)

    Angele, W.

    1972-01-01

    Flat conductor cable (FCC) is relatively new, highly promising means for electrical packaging and system integration. FCC offers numerous desirable traits (weight, volume and cost savings, flexibility, high reliability, predictable and repeatable electrical characteristics) which make it extremely attractive as a packaging medium. FCC, today, finds wide application in everything from integration of lunar equipment to the packaging of electronics in nuclear submarines. Described are cable construction and means of termination, applicable specifications and standards, and total FCC systems. A list of additional sources of data is also included for more intensive study.

  4. Reliability and Construct Validity of the Patient-Reported Outcomes Measurement Information System (PROMIS) Instruments in Women with Fibromyalgia.

    PubMed

    Merriwether, Ericka N; Rakel, Barbara A; Zimmerman, Miriam B; Dailey, Dana L; Vance, Carol G T; Darghosian, Leon; Golchha, Meenakshi; Geasland, Katherine M; Chimenti, Ruth; Crofford, Leslie J; Sluka, Kathleen A

    2017-08-01

    The Patient-Reported Outcomes Measurement Information System (PROMIS) was developed to standardize measurement of clinically relevant patient-reported outcomes. This study evaluated the reliability and construct validity of select PROMIS static short-form (SF) instruments in women with fibromyalgia. Analysis of baseline data from the Fibromyalgia Activity Study with TENS (FAST), a randomized controlled trial of the efficacy of transcutaneous electrical nerve stimulation. Dual site, university-based outpatient clinics. Women aged 20 to 67 years diagnosed with fibromyalgia. Participants completed the Revised Fibromyalgia Impact Questionnaire (FIQR) and 10 PROMIS static SF instruments. Internal consistency was calculated using Cronbach alpha. Convergent validity was examined against the FIQR using Pearson correlation and multiple regression analysis. PROMIS static SF instruments had fair to high internal consistency (Cronbach α = 0.58 to 0.94, P  < 0.05). PROMIS 'physical function' domain score was highly correlated with FIQR 'function' score (r = -0.73). The PROMIS 'total' score was highly correlated with the FIQR total score (r = -0.72). Correlations with FIQR total score of each of the three PROMIS domain scores were r = -0.65 for 'physical function,' r = -0.63 for 'global,' and r = -0.57 for 'symptom' domain. PROMIS 'physical function,' 'global,' and 'symptom' scores explained 58% of the FIQR total score variance. Select PROMIS static SF instruments demonstrate convergent validity with the FIQR, a legacy measure of fibromyalgia disease severity. These results highlight the potential utility of select PROMIS static SFs for assessment and tracking of patient-reported outcomes in fibromyalgia. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  5. On the Path to SunShot. The Role of Advancements in Solar Photovoltaic Efficiency, Reliability, and Costs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woodhouse, Michael; Jones-Albertus, Rebecca; Feldman, David

    2016-05-01

    This report examines the remaining challenges to achieving the competitive photovoltaic (PV) costs and large-scale deployment envisioned under the U.S. Department of Energy's SunShot Initiative. Solar-energy cost reductions can be realized through lower PV module and balance-of-system (BOS) costs as well as improved system efficiency and reliability. Numerous combinations of PV improvements could help achieve the levelized cost of electricity (LCOE) goals because of the tradeoffs among key metrics like module price, efficiency, and degradation rate as well as system price and lifetime. Using LCOE modeling based on bottom-up cost analysis, two specific pathways are mapped to exemplify the manymore » possible approaches to module cost reductions of 29%-38% between 2015 and 2020. BOS hardware and soft cost reductions, ranging from 54%-77% of total cost reductions, are also modeled. The residential sector's high supply-chain costs, labor requirements, and customer-acquisition costs give it the greatest BOS cost-reduction opportunities, followed by the commercial sector, although opportunities are available to the utility-scale sector as well. Finally, a future scenario is considered in which very high PV penetration requires additional costs to facilitate grid integration and increased power-system flexibility--which might necessitate even lower solar LCOEs. The analysis of a pathway to 3-5 cents/kWh PV systems underscores the importance of combining robust improvements in PV module and BOS costs as well as PV system efficiency and reliability if such aggressive long-term targets are to be achieved.« less

  6. Checklist and Scoring System for the Assessment of Soft Tissue Preservation in CT Examinations of Human Mummies.

    PubMed

    Panzer, Stephanie; Mc Coy, Mark R; Hitzl, Wolfgang; Piombino-Mascali, Dario; Jankauskas, Rimantas; Zink, Albert R; Augat, Peter

    2015-01-01

    The purpose of this study was to develop a checklist for standardized assessment of soft tissue preservation in human mummies based on whole-body computed tomography examinations, and to add a scoring system to facilitate quantitative comparison of mummies. Computed tomography examinations of 23 mummies from the Capuchin Catacombs of Palermo, Sicily (17 adults, 6 children; 17 anthropogenically and 6 naturally mummified) and 7 mummies from the crypt of the Dominican Church of the Holy Spirit of Vilnius, Lithuania (5 adults, 2 children; all naturally mummified) were used to develop the checklist following previously published guidelines. The scoring system was developed by assigning equal scores for checkpoints with equivalent quality. The checklist was evaluated by intra- and inter-observer reliability. The finalized checklist was applied to compare the groups of anthropogenically and naturally mummified bodies. The finalized checklist contains 97 checkpoints and was divided into two main categories, "A. Soft Tissues of Head and Musculoskeletal System" and "B. Organs and Organ Systems", each including various subcategories. The complete checklist had an intra-observer reliability of 98% and an inter-observer reliability of 93%. Statistical comparison revealed significantly higher values in anthropogenically compared to naturally mummified bodies for the total score and for three subcategories. In conclusion, the developed checklist allows for a standardized assessment and documentation of soft tissue preservation in whole-body computed tomography examinations of human mummies. The scoring system facilitates a quantitative comparison of the soft tissue preservation status between single mummies or mummy collections.

  7. System reliability approaches for advanced propulsion system structures

    NASA Technical Reports Server (NTRS)

    Cruse, T. A.; Mahadevan, S.

    1991-01-01

    This paper identifies significant issues that pertain to the estimation and use of system reliability in the design of advanced propulsion system structures. Linkages between the reliabilities of individual components and their effect on system design issues such as performance, cost, availability, and certification are examined. The need for system reliability computation to address the continuum nature of propulsion system structures and synergistic progressive damage modes has been highlighted. Available system reliability models are observed to apply only to discrete systems. Therefore a sequential structural reanalysis procedure is formulated to rigorously compute the conditional dependencies between various failure modes. The method is developed in a manner that supports both top-down and bottom-up analyses in system reliability.

  8. High-resolution audiometry: an automated method for hearing threshold acquisition with quality control.

    PubMed

    Bian, Lin

    2012-01-01

    In clinical practice, hearing thresholds are measured at only five to six frequencies at octave intervals. Thus, the audiometric configuration cannot closely reflect the actual status of the auditory structures. In addition, differential diagnosis requires quantitative comparison of behavioral thresholds with physiological measures, such as otoacoustic emissions (OAEs) that are usually measured in higher resolution. The purpose of this research was to develop a method to improve the frequency resolution of the audiogram. A repeated-measure design was used in the study to evaluate the reliability of the threshold measurements. A total of 16 participants with clinically normal hearing and mild hearing loss were recruited from a population of university students. No intervention was involved in the study. Custom developed system and software were used for threshold acquisition with quality control (QC). With real-ear calibration and monitoring of test signals, the system provided accurate and individualized measure of hearing thresholds that were determined by an analysis based on signal detection theory (SDT). The reliability of the threshold measure was assessed by correlation and differences between the repeated measures. The audiometric configurations were diverse and unique to each individual ear. The accuracy, within-subject reliability, and between-test repeatability are relatively high. With QC, the high-resolution audiograms can be reliably and accurately measured. Hearing thresholds measured as ear canal sound pressures with higher frequency resolution can provide more customized hearing-aid fitting. The test system may be integrated with other physiological measures, such as OAEs, into a comprehensive evaluative tool. American Academy of Audiology.

  9. Extraction of In-Medium Nucleon-Nucleon Amplitude From Experiment

    NASA Technical Reports Server (NTRS)

    Tripathi, R. K.; Cucinotta, Francis A.; Wilson, John W.

    1998-01-01

    The in-medium nucleon-nucleon amplitudes are extracted from the available proton-nucleus total reaction cross sections data. The retrieval of the information from the experiment makes the estimate of reaction cross sections very reliable. Simple expressions are given for the in-medium nucleon-nucleon amplitudes for any system of colliding nuclei as a function of energy. Excellent agreement with experimental observations is demonstrated in the ion-nucleus interactions.

  10. Reliability and validity of the delta finger-to-palm (FTP), a new measure of finger range of motion in systemic sclerosis.

    PubMed

    Torok, Kathryn S; Baker, Nancy A; Lucas, Mary; Domsic, Robyn T; Boudreau, Robert; Medsger, Thomas A

    2010-01-01

    To determine the reliability and validity of a new measure of finger motion in patients with systemic sclerosis (SSc), the 'delta finger-topalm' (delta FTP) and compare its psychometric properties to the traditional measure of finger motion, the finger-topalm (FTP). Phase 1: The reliability of the delta FTP and FTP were examined in 39 patients with SSc. Phase 2: Criterion and convergent construct validity of both measures were examined in 17 patients with SSc by comparing them to other clinical measures: Total Active Range of Motion (TAROM), Hand Mobility in Scleroderma (HAMIS), the Duruoz Hand Index (DHI), Health Assessment Questionnaire (HAQ), and modified Rodnan skin score (mRSS). Phase 3: Sensitivity to change of the delta FTP was investigated in 24 patients with early diffuse cutaneous SSc. Both measures had excellent intra-rater and inter-rater reliability (ICC 0.92 to 0.99). Fair to strong correlations (rs=0.49-0.94) were observed between the delta FTP and TAROM, HAMIS, and DHI. Fair to moderate correlations were observed between delta FTP and HAQ components related to hand function and upper extremity mRSS. Correlations of the traditional FTP with these measures were fair to strong, but most often the delta FTP outperformed the FTP. The effect size and standardised response mean for the mean delta FTP were 0.50 and 1.10 respectively, over a 2-8 month period. The delta FTP is a valid and reliable measure of finger motion in patients with SSc which outperforms the FTP.

  11. A study of the reliability of the Nociception Coma Scale.

    PubMed

    Riganello, F; Cortese, M D; Arcuri, F; Candelieri, A; Guglielmino, F; Dolce, G; Sannita, W G; Schnakers, C

    2015-04-01

    In this study, we investigated the reliability of the Nociception Coma Scale which has recently been developed to assess nociception in non-communicative, severely brain-injured patients. Prospective cross-sequential study. Semi-intensive care unit and long-term brain injury care. Forty-four patients diagnosed as being in a vegetative state (n=26) or in a minimally conscious state (n=18). Patients were assessed by two experts (rater A and rater B) on two consecutive weeks to measure inter-rater agreement and test-retest reliability. Total scores and subscores of the Nociception Coma Scale. We performed a total of 176 assessments. The inter-rater agreement was moderate for the total scores (k = 0.57) and fair to substantial for the subscores (0.33 ≤ k ≤ 0.62) on week 2. The test-retest reliability was substantial for the total scores (k = 0.66) and moderate to almost perfect for the subscores (0.53 ≤ k ≤ 0.96) for rater A. The inter-rater agreement was weaker on week 1, whereas the test-retest reliability was lower for the least experienced rater (rater B). This study provides further evidence of the psychometric qualities of the Nociception Coma Scale. Future studies should assess the impact of practical experience and background on administration and scoring of the scale. © The Author(s) 2014.

  12. 75 FR 72664 - System Personnel Training Reliability Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-26

    ...Under section 215 of the Federal Power Act, the Commission approves two Personnel Performance, Training and Qualifications (PER) Reliability Standards, PER-004-2 (Reliability Coordination--Staffing) and PER-005-1 (System Personnel Training), submitted to the Commission for approval by the North American Electric Reliability Corporation, the Electric Reliability Organization certified by the Commission. The approved Reliability Standards require reliability coordinators, balancing authorities, and transmission operators to establish a training program for their system operators, verify each of their system operators' capability to perform tasks, and provide emergency operations training to every system operator. The Commission also approves NERC's proposal to retire two existing PER Reliability Standards that are replaced by the standards approved in this Final Rule.

  13. Results of a Demonstration Assessment of Passive System Reliability Utilizing the Reliability Method for Passive Systems (RMPS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bucknor, Matthew; Grabaskas, David; Brunett, Acacia

    2015-04-26

    Advanced small modular reactor designs include many advantageous design features such as passively driven safety systems that are arguably more reliable and cost effective relative to conventional active systems. Despite their attractiveness, a reliability assessment of passive systems can be difficult using conventional reliability methods due to the nature of passive systems. Simple deviations in boundary conditions can induce functional failures in a passive system, and intermediate or unexpected operating modes can also occur. As part of an ongoing project, Argonne National Laboratory is investigating various methodologies to address passive system reliability. The Reliability Method for Passive Systems (RMPS), amore » systematic approach for examining reliability, is one technique chosen for this analysis. This methodology is combined with the Risk-Informed Safety Margin Characterization (RISMC) approach to assess the reliability of a passive system and the impact of its associated uncertainties. For this demonstration problem, an integrated plant model of an advanced small modular pool-type sodium fast reactor with a passive reactor cavity cooling system is subjected to a station blackout using RELAP5-3D. This paper discusses important aspects of the reliability assessment, including deployment of the methodology, the uncertainty identification and quantification process, and identification of key risk metrics.« less

  14. A spin-recovery parachute system for light general-aviation airplanes

    NASA Technical Reports Server (NTRS)

    Bradshaw, C.

    1980-01-01

    A tail mounted spin recovery parachute system was designed and developed for use on light general aviation airplanes. The system was designed for use on typical airplane configurations, including low wing, high wing, single engine and twin engine designs. A mechanically triggered pyrotechnic slug gun is used to forcibly deploy a pilot parachute which extracts a bag that deploys a ring slot spin recovery parachute. The total system weighs 8.2 kg. System design factors included airplane wake effects on parachute deployment, prevention of premature parachute deployment, positive parachute jettison, compact size, low weight, system reliability, and pilot and ground crew safety. Extensive ground tests were conducted to qualify the system. The recovery parachute was used successfully in flight 17 times.

  15. Reliability and validity of migraine disability assessment questionnaire-Thai version (Thai-MIDAS).

    PubMed

    Seethong, Piman; Nimmannit, Akarin; Chaisewikul, Rungsan; Prayoonwiwat, Naraporn; Chotinaiwattarakul, Wattanachai

    2013-02-01

    To assess the validity and test-retest reliability of a Thai translation of the Migraine Disability Assessment (MIDAS) Questionnaire in Thai patients with migraine. Migraineurs from the Headache Clinic in Siriraj Hospital were recruited and asked to complete a 13-weeks diary and answered the Thai-MIDAS at once. Some participants were asked to provide the 2nd Thai-MIDAS in the next 2 weeks for test-retest reliability. Ninety-three patients had completed the 13-weeks diaries. Age range was 18-58 years with mean 37.69 +/- 9.60 years. All 5 items and the total score of Thai-MIDAS were moderately correlated with data from 13-weeks diary (Spearman's correlation coefficient = 0.32-0.62). The test-retest reliability of the total score of Thai-MIDAS in 30 patients demonstrated a highly reliable degree of intraclass correlation (ICC = 0.76, 95% CI 0.49-0.88). The present study reveals that the Thai-MIDAS has satisfactory validity and reliability in comparison with the original English MIDAS version.

  16. Operational Experience of the Upgraded Cryogenic Systems at the Nscl

    NASA Astrophysics Data System (ADS)

    McCartney, A. H.; Laumer, H. L.; Jones, S. A.

    2010-04-01

    The National Superconducting Cyclotron Laboratory (NSCL) is a NSF-supported facility, with additional support from Michigan State University (MSU) for conducting research in nuclear and accelerator science. The facility consists of two superconducting cyclotrons and over fifty individual cryostats, each containing several superconducting magnets that are used in the beam transport system. Beginning in 1999 a major facility upgrade was started. New, larger magnets were added, increasing the total 4.5 K loads, necessitating an increase of the cryogenic capacity. A helium plant (nominal 1750-Watt at 4.5 K) was acquired from the United States Bureau of Mines where it had been operating as a pure liquefier since the early 1980's. It was refurbished for the NSCL with extensive support from the cryogenics group at Thomas Jefferson National Laboratory. The new cryogenic system came online early in 2001. The cold-mass is relatively high in relation to the installed capacity, presenting challenges during cool downs. Reliability over the last five years has been greater than 99%. An overview of the last seven years of operations of our cryogenic systems is presented that includes normal operations, testing of new equipment, noteworthy breakdowns, routine maintenance, and system reliability.

  17. Cross-cultural adaptation and validation of the Behcet's Disease Current Activity Form in Korea.

    PubMed

    Choi, Hyo Jin; Seo, Mi Ryoung; Ryu, Hee Jung; Baek, Han Joo

    2015-09-01

    This study was undertaken to perform a cross-cultural adaptation of the Behcet's Disease Current Activity Form (BDCAF, version 2006) questionnaire to the Korean language and to evaluate its reliability and validity in a population of Korean patients with Behcet's disease (BD). A cross-cultural study was conducted among patients with BD who attended our rheumatology clinic between November 2012 and March 2013. There were 11 males and 35 females in the group. The mean age of the participants was 48.5 years and the mean disease duration was 6.4 years. The first BDCAF questionnaire was completed on arrival and the second assessment was performed 20 minutes later by a different physician. The test-retest reliability was analyzed by computing κ statistics. Kappa scores of > 0.6 indicated a good agreement. To assess the validity, we compared the total BDCAF score with the patient's/clinician's perception of disease activity and the Korean version of the Behcet's Disease Quality of Life (BDQOL). For the test-retest reliability, good agreements were achieved on items such as headache, oral/genital ulceration, erythema, skin pustules, arthralgia, nausea/vomiting/abdominal pain, and diarrhea with altered/frank blood per rectum. Moderate agreement was observed for eye and nervous system involvement. We achieved a fair agreement for arthritis and major vessel involvement. Significant correlations were obtained between the total BDCAF score with the BDQOL and the patient's/clinician's perception of disease activity p < 0.05). The Korean version of the BDCAF is a reliable and valid instrument for measuring current disease activity in Korean BD patients.

  18. [Formula: see text]Interpreting change on the neurobehavioral symptom inventory and the PTSD checklist in military personnel.

    PubMed

    Belanger, Heather G; Lange, Rael T; Bailie, Jason; Iverson, Grant L; Arrieux, Jacques P; Ivins, Brian J; Cole, Wesley R

    2016-10-01

    The purpose of this study was to examine the prevalence and stability of symptom reporting in a healthy military sample and to develop reliable change indices for two commonly used self-report measures in the military health care system. Participants were 215 U.S. active duty service members recruited from Fort Bragg, NC as normal controls as part of a larger study. Participants completed the Neurobehavioral Symptom Inventory (NSI) and Posttraumatic Checklist (PCL) twice, separated by approximately 30 days. Depending on the endorsement level used (i.e. ratings of 'mild' or greater vs. ratings of 'moderate' or greater), approximately 2-15% of this sample met DSM-IV symptom criteria for Postconcussional Disorder across time points, while 1-6% met DSM-IV symptom criteria for Posttraumatic Stress Disorder. Effect sizes for change from Time 1 to Time 2 on individual symptoms were small (Cohen's d = .01 to .13). The test-retest reliability for the NSI total score was r = .78 and the PCL score was r = .70. An eight-point change in symptom reporting represented reliable change on the NSI total score, with a seven-point change needed on the PCL. Postconcussion-like symptoms are not unique to mild TBI and are commonly reported in a healthy soldier sample. It is important for clinicians to use normative data when evaluating a service member or veteran and when evaluating the likelihood that a change in symptom reporting is reliable and clinically meaningful.

  19. A comprehensive scoring system to measure healthy community design in land use plans and regulations.

    PubMed

    Maiden, Kristin M; Kaplan, Marina; Walling, Lee Ann; Miller, Patricia P; Crist, Gina

    2017-02-01

    Comprehensive land use plans and their corresponding regulations play a role in determining the nature of the built environment and community design, which are factors that influence population health and health disparities. To determine the level in which a plan addresses healthy living and active design, there is a need for a systematic, reliable and valid method of analyzing and scoring health-related content in plans and regulations. This paper describes the development and validation of a scoring tool designed to measure the strength and comprehensiveness of health-related content found in land use plans and the corresponding regulations. The measures are scored based on the presence of a specific item and the specificity and action-orientation of language. To establish reliability and validity, 42 land use plans and regulations from across the United States were scored January-April 2016. Results of the psychometric analysis indicate the scorecard is a reliable scoring tool for land use plans and regulations related to healthy living and active design. Intraclass correlation coefficients (ICC) scores showed strong inter-rater reliability for total strength and comprehensiveness. ICC scores for total implementation scores showed acceptable consistency among scorers. Cronbach's alpha values for all focus areas were acceptable. Strong content validity was measured through a committee vetting process. The development of this tool has far-reaching implications, bringing standardization of measurement to the field of land use plan assessment, and paving the way for systematic inclusion of health-related design principles, policies, and requirements in land use plans and their corresponding regulations. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Psychometric Properties of Difficulties of Working with Patients with Personality Disorders and Attitudes Towards Patients with Personality Disorders Scales.

    PubMed

    Eren, Nurhan

    2014-12-01

    In this study, we aimed to develop two reliable and valid assessment instruments for investigating the level of difficulties mental health workers experience while working with patients with personality disorders and the attitudes they develop tt the patients. The research was carried out based on the general screening model. The study sample consisted of 332 mental health workers in several mental health clinics of Turkey, with a certain amount of experience in working with personality disorders, who were selected with a random assignment method. In order to collect data, the Personal Information Questionnaire, Difficulty of Working with Personality Disorders Scale (PD-DWS), and Attitudes Towards Patients with Personality Disorders Scale (PD-APS), which are being examined for reliability and validity, were applied. To determine construct validity, the Adjective Check List, Maslach Burnout Inventory, and State and Trait Anxiety Inventory were used. Explanatory factor analysis was used for investigating the structural validity, and Cronbach alpha, Spearman-Brown, Guttman Split-Half reliability analyses were utilized to examine the reliability. Also, item reliability and validity computations were carried out by investigating the corrected item-total correlations and discriminative indexes of the items in the scales. For the PD-DWS KMO test, the value was .946; also, a significant difference was found for the Bartlett sphericity test (p<.001). The computed test-retest coefficient reliability was .702; the Cronbach alpha value of the total test score was .952. For PD-APS KMO, the value was .925; a significant difference was found in Bartlett sphericity test (p<.001); the computed reliability coefficient based on continuity was .806; and the Cronbach alpha value of the total test score was .913. Analyses on both scales were based on total scores. It was found that PD-DWS and PD-APS have good psychometric properties, measuring the structure that is being investigated, are compatible with other scales, have high levels of internal reliability between their items, and are consistent across time. Therefore, it was concluded that both scales are valid and reliable instruments.

  1. Developing Reliable Life Support for Mars

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.

    2017-01-01

    A human mission to Mars will require highly reliable life support systems. Mars life support systems may recycle water and oxygen using systems similar to those on the International Space Station (ISS). However, achieving sufficient reliability is less difficult for ISS than it will be for Mars. If an ISS system has a serious failure, it is possible to provide spare parts, or directly supply water or oxygen, or if necessary bring the crew back to Earth. Life support for Mars must be designed, tested, and improved as needed to achieve high demonstrated reliability. A quantitative reliability goal should be established and used to guide development t. The designers should select reliable components and minimize interface and integration problems. In theory a system can achieve the component-limited reliability, but testing often reveal unexpected failures due to design mistakes or flawed components. Testing should extend long enough to detect any unexpected failure modes and to verify the expected reliability. Iterated redesign and retest may be required to achieve the reliability goal. If the reliability is less than required, it may be improved by providing spare components or redundant systems. The number of spares required to achieve a given reliability goal depends on the component failure rate. If the failure rate is under estimated, the number of spares will be insufficient and the system may fail. If the design is likely to have undiscovered design or component problems, it is advisable to use dissimilar redundancy, even though this multiplies the design and development cost. In the ideal case, a human tended closed system operational test should be conducted to gain confidence in operations, maintenance, and repair. The difficulty in achieving high reliability in unproven complex systems may require the use of simpler, more mature, intrinsically higher reliability systems. The limitations of budget, schedule, and technology may suggest accepting lower and less certain expected reliability. A plan to develop reliable life support is needed to achieve the best possible reliability.

  2. Calculating system reliability with SRFYDO

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morzinski, Jerome; Anderson - Cook, Christine M; Klamann, Richard M

    2010-01-01

    SRFYDO is a process for estimating reliability of complex systems. Using information from all applicable sources, including full-system (flight) data, component test data, and expert (engineering) judgment, SRFYDO produces reliability estimates and predictions. It is appropriate for series systems with possibly several versions of the system which share some common components. It models reliability as a function of age and up to 2 other lifecycle (usage) covariates. Initial output from its Exploratory Data Analysis mode consists of plots and numerical summaries so that the user can check data entry and model assumptions, and help determine a final form for themore » system model. The System Reliability mode runs a complete reliability calculation using Bayesian methodology. This mode produces results that estimate reliability at the component, sub-system, and system level. The results include estimates of uncertainty, and can predict reliability at some not-too-distant time in the future. This paper presents an overview of the underlying statistical model for the analysis, discusses model assumptions, and demonstrates usage of SRFYDO.« less

  3. Development and reliability of a structured interview guide for the Montgomery Asberg Depression Rating Scale (SIGMA).

    PubMed

    Williams, Janet B W; Kobak, Kenneth A

    2008-01-01

    The Montgomery-Asberg Depression Rating Scale (MADRS) is often used in clinical trials to select patients and to assess treatment efficacy. The scale was originally published without suggested questions for clinicians to use in gathering the information necessary to rate the items. Structured and semi-structured interview guides have been found to improve reliability with other scales. To describe the development and test-retest reliability of a structured interview guide for the MADRS (SIGMA). A total of 162 test-retest interviews were conducted by 81 rater pairs. Each patient was interviewed twice, once by each rater conducting an independent interview. The intraclass correlation for total score between raters using the SIGMA was r=0.93, P<0.0001. All ten items had good to excellent interrater reliability. Use of the SIGMA can result in high reliability of MADRS scores in evaluating patients with depression.

  4. Methods and Costs to Achieve Ultra Reliable Life Support

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.

    2012-01-01

    A published Mars mission is used to explore the methods and costs to achieve ultra reliable life support. The Mars mission and its recycling life support design are described. The life support systems were made triply redundant, implying that each individual system will have fairly good reliability. Ultra reliable life support is needed for Mars and other long, distant missions. Current systems apparently have insufficient reliability. The life cycle cost of the Mars life support system is estimated. Reliability can be increased by improving the intrinsic system reliability, adding spare parts, or by providing technically diverse redundant systems. The costs of these approaches are estimated. Adding spares is least costly but may be defeated by common cause failures. Using two technically diverse systems is effective but doubles the life cycle cost. Achieving ultra reliability is worth its high cost because the penalty for failure is very high.

  5. Reliability and Validity of a New Method for Isometric Back Extensor Strength Evaluation Using A Hand-Held Dynamometer.

    PubMed

    Park, Hee-Won; Baek, Sora; Kim, Hong Young; Park, Jung-Gyoo; Kang, Eun Kyoung

    2017-10-01

    To investigate the reliability and validity of a new method for isometric back extensor strength measurement using a portable dynamometer. A chair equipped with a small portable dynamometer was designed (Power Track II Commander Muscle Tester). A total of 15 men (mean age, 34.8±7.5 years) and 15 women (mean age, 33.1±5.5 years) with no current back problems or previous history of back surgery were recruited. Subjects were asked to push the back of the chair while seated, and their isometric back extensor strength was measured by the portable dynamometer. Test-retest reliability was assessed with intraclass correlation coefficient (ICC). For the validity assessment, isometric back extensor strength of all subjects was measured by a widely used physical performance evaluation instrument, BTE PrimusRS system. The limit of agreement (LoA) from the Bland-Altman plot was evaluated between two methods. The test-retest reliability was excellent (ICC=0.82; 95% confidence interval, 0.65-0.91). The Bland-Altman plots demonstrated acceptable agreement between the two methods: the lower 95% LoA was -63.1 N and the upper 95% LoA was 61.1 N. This study shows that isometric back extensor strength measurement using a portable dynamometer has good reliability and validity.

  6. Prediction of wastewater quality indicators at the inflow to the wastewater treatment plant using data mining methods

    NASA Astrophysics Data System (ADS)

    Szeląg, Bartosz; Barbusiński, Krzysztof; Studziński, Jan; Bartkiewicz, Lidia

    2017-11-01

    In the study, models developed using data mining methods are proposed for predicting wastewater quality indicators: biochemical and chemical oxygen demand, total suspended solids, total nitrogen and total phosphorus at the inflow to wastewater treatment plant (WWTP). The models are based on values measured in previous time steps and daily wastewater inflows. Also, independent prediction systems that can be used in case of monitoring devices malfunction are provided. Models of wastewater quality indicators were developed using MARS (multivariate adaptive regression spline) method, artificial neural networks (ANN) of the multilayer perceptron type combined with the classification model (SOM) and cascade neural networks (CNN). The lowest values of absolute and relative errors were obtained using ANN+SOM, whereas the MARS method produced the highest error values. It was shown that for the analysed WWTP it is possible to obtain continuous prediction of selected wastewater quality indicators using the two developed independent prediction systems. Such models can ensure reliable WWTP work when wastewater quality monitoring systems become inoperable, or are under maintenance.

  7. Reliability of sonographic assessment of tendinopathy in tennis elbow.

    PubMed

    Poltawski, Leon; Ali, Syed; Jayaram, Vijay; Watson, Tim

    2012-01-01

    To assess the reliability and compute the minimum detectable change using sonographic scales to quantify the extent of pathology and hyperaemia in the common extensor tendon in people with tennis elbow. The lateral elbows of 19 people with tennis elbow were assessed sonographically twice, 1-2 weeks apart. Greyscale and power Doppler images were recorded for subsequent rating of abnormalities. Tendon thickening, hypoechogenicity, fibrillar disruption and calcification were each rated on four-point scales, and scores were summed to provide an overall rating of structural abnormality; hyperaemia was scored on a five point scale. Inter-rater reliability was established using the intraclass correlation coefficient (ICC) to compare scores assigned independently to the same set of images by a radiologist and a physiotherapist with training in musculoskeletal imaging. Test-retest reliability was assessed by comparing scores assigned by the physiotherapist to images recorded at the two sessions. The minimum detectable change (MDC) was calculated from the test-retest reliability data. ICC values for inter-rater reliability ranged from 0.35 (95% CI: 0.05, 0.60) for fibrillar disruption to 0.77 (0.55, 0.88) for overall greyscale score, and 0.89 (0.79, 0.95) for hyperaemia. Test-retest reliability ranged from 0.70 (0.48, 0.84) for tendon thickening to 0.82 (0.66, 0.90) for overall greyscale score and 0.86 (0.73, 0.93) for calcification. The MDC for the greyscale total score was 2.0/12 and for the hyperaemia score was 1.1/5. The sonographic scoring system used in this study may be used reliably to quantify tendon abnormalities and change over time. A relatively inexperienced imager can conduct the assessment and use the rating scales reliably.

  8. Reliability and concurrent validity of postural asymmetry measurement in adolescent idiopathic scoliosis.

    PubMed

    Prowse, Ashleigh; Aslaksen, Berit; Kierkegaard, Marie; Furness, James; Gerdhem, Paul; Abbott, Allan

    2017-01-18

    To investigate the reliability and concurrent validity of the Baseline ® Body Level/Scoliosis meter for adolescent idiopathic scoliosis postural assessment in three anatomical planes. This is an observational reliability and concurrent validity study of adolescent referrals to the Orthopaedic department for scoliosis screening at Karolinska University Hospital, Stockholm, Sweden between March-May 2012. A total of 31 adolescents with idiopathic scoliosis (13.6 ± 0.6 years old) of mild-moderate curvatures (25° ± 12°) were consecutively recruited. Measurement of cervical, thoracic and lumbar curvatures, pelvic and shoulder tilt, and axial thoracic rotation (ATR) were performed by two trained physiotherapists in one day. The intraclass correlation coefficient (ICC) was used to determine the inter-examiner reliability (ICC2,1) and the intra-rater reliability (ICC3,3) of the Baseline ® Body Level/Scoliosis meter. Spearman's correlation analyses were used to estimate concurrent validity between the Baseline ® Body Level/Scoliosis meter and Gold Standard Cobb angles from radiographs and the Orthopaedic Systems Inc. Scoliometer. There was excellent reliability between examiners for thoracic kyphosis (ICC2,1 = 0.94), ATR (ICC2,1 = 0.92) and lumbar lordosis (ICC2,1 = 0.79). There was adequate reliability between examiners for cervical lordosis (ICC2,1 = 0.51), however poor reliability for pelvic and shoulder tilt. Both devices were reproducible in the measurement of ATR when repeated by one examiner (ICC3,3 0.98-1.00). The device had a good correlation with the Scoliometer (rho = 0.78). When compared with Cobb angle from radiographs, there was a moderate correlation for ATR (rho = 0.627). The Baseline ® Body Level/Scoliosis meter provides reliable transverse and sagittal cervical, thoracic and lumbar measurements and valid transverse plan measurements of mild-moderate scoliosis deformity.

  9. Fuzzy probabilistic design of water distribution networks

    NASA Astrophysics Data System (ADS)

    Fu, Guangtao; Kapelan, Zoran

    2011-05-01

    The primary aim of this paper is to present a fuzzy probabilistic approach for optimal design and rehabilitation of water distribution systems, combining aleatoric and epistemic uncertainties in a unified framework. The randomness and imprecision in future water consumption are characterized using fuzzy random variables whose realizations are not real but fuzzy numbers, and the nodal head requirements are represented by fuzzy sets, reflecting the imprecision in customers' requirements. The optimal design problem is formulated as a two-objective optimization problem, with minimization of total design cost and maximization of system performance as objectives. The system performance is measured by the fuzzy random reliability, defined as the probability that the fuzzy head requirements are satisfied across all network nodes. The satisfactory degree is represented by necessity measure or belief measure in the sense of the Dempster-Shafer theory of evidence. An efficient algorithm is proposed, within a Monte Carlo procedure, to calculate the fuzzy random system reliability and is effectively combined with the nondominated sorting genetic algorithm II (NSGAII) to derive the Pareto optimal design solutions. The newly proposed methodology is demonstrated with two case studies: the New York tunnels network and Hanoi network. The results from both cases indicate that the new methodology can effectively accommodate and handle various aleatoric and epistemic uncertainty sources arising from the design process and can provide optimal design solutions that are not only cost-effective but also have higher reliability to cope with severe future uncertainties.

  10. Improved methods for venous access: the Port-A-Cath, a totally implanted catheter system.

    PubMed

    Strum, S; McDermed, J; Korn, A; Joseph, C

    1986-04-01

    We prospectively evaluated the performance and rate of long-term complications with the Port-A-Cath (PAC), a totally implanted vascular access system. Two catheter styles were evaluated, a small-bore (SB) catheter (0.51-mm diameter) and a large-bore (LB) catheter (1.02-mm diameter), in conjunction with the use of a strict catheter care protocol. The PAC performed well, and with both SB and LB systems, no significant extravasation, skin necrosis, hematoma, septum damage or leakage, or subcutaneous portal infections occurred after 7,240 days of implantation and 1,435 days of use. Complications with the PAC system consisted of catheter occlusion (seven patients, 21.5%) and one instance of possible catheter infection (3.1%). Occlusions were limited to patients implanted with the SB catheter (seven of 16, 43.8%), and five of the seven (71.4%) occurred in patients receiving continuous infusion chemotherapy and/or total parenteral nutrition. Patency of the PAC system was maintained using a regular flushing schedule once every 30 days, a significant advantage compared with the daily maintenance schedule required with externally placed venous catheters. The results of this study suggest that the PAC system can provide a safe and reliable method for venous access in patients requiring intermittent or prolonged intravenous therapy.

  11. HiRel: Hybrid Automated Reliability Predictor (HARP) integrated reliability tool system, (version 7.0). Volume 1: HARP introduction and user's guide

    NASA Technical Reports Server (NTRS)

    Bavuso, Salvatore J.; Rothmann, Elizabeth; Dugan, Joanne Bechta; Trivedi, Kishor S.; Mittal, Nitin; Boyd, Mark A.; Geist, Robert M.; Smotherman, Mark D.

    1994-01-01

    The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed to be compatible with most computing platforms and operating systems, and some programs have been beta tested, within the aerospace community for over 8 years. Volume 1 provides an introduction to the HARP program. Comprehensive information on HARP mathematical models can be found in the references.

  12. Inter-session reliability and sex-related differences in hamstrings total reaction time, pre-motor time and motor time during eccentric isokinetic contractions in recreational athlete.

    PubMed

    Ayala, Francisco; De Ste Croix, Mark; Sainz de Baranda, Pilar; Santonja, Fernando

    2014-04-01

    The purposes were twofold: (a) to ascertain the inter-session reliability of hamstrings total reaction time, pre-motor time and motor time; and (b) to examine sex-related differences in the hamstrings reaction times profile. Twenty-four men and 24 women completed the study. Biceps femoris and semitendinosus total reaction time, pre-motor time and motor time measured during eccentric isokinetic contractions were recorded on three different occasions. Inter-session reliability was examined through typical percentage error (CVTE), percentage change in the mean (CM) and intraclass correlations (ICC). For both biceps femoris and semitendinosus, total reaction time, pre-motor time and motor time measures demonstrated moderate inter-session reliability (CVTE<10%; CM<3%; ICC>0.7). The results also indicated that, although not statistically significant, women reported consistently longer hamstrings total reaction time (23.5ms), pre-motor time (12.7ms) and motor time (7.5ms) values than men. Therefore, an observed change larger than 5%, 9% and 8% for total reaction time, pre-motor time and motor time respectively from baseline scores after performing a training program would indicate that a real change was likely. Furthermore, while not statistically significant, sex differences were noted in the hamstrings reaction time profile which may play a role in the greater incidence of ACL injuries in women. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. The accuracy of Internet search engines to predict diagnoses from symptoms can be assessed with a validated scoring system.

    PubMed

    Shenker, Bennett S

    2014-02-01

    To validate a scoring system that evaluates the ability of Internet search engines to correctly predict diagnoses when symptoms are used as search terms. We developed a five point scoring system to evaluate the diagnostic accuracy of Internet search engines. We identified twenty diagnoses common to a primary care setting to validate the scoring system. One investigator entered the symptoms for each diagnosis into three Internet search engines (Google, Bing, and Ask) and saved the first five webpages from each search. Other investigators reviewed the webpages and assigned a diagnostic accuracy score. They rescored a random sample of webpages two weeks later. To validate the five point scoring system, we calculated convergent validity and test-retest reliability using Kendall's W and Spearman's rho, respectively. We used the Kruskal-Wallis test to look for differences in accuracy scores for the three Internet search engines. A total of 600 webpages were reviewed. Kendall's W for the raters was 0.71 (p<0.0001). Spearman's rho for test-retest reliability was 0.72 (p<0.0001). There was no difference in scores based on Internet search engine. We found a significant difference in scores based on the webpage's order on the Internet search engine webpage (p=0.007). Pairwise comparisons revealed higher scores in the first webpages vs. the fourth (corr p=0.009) and fifth (corr p=0.017). However, this significance was lost when creating composite scores. The five point scoring system to assess diagnostic accuracy of Internet search engines is a valid and reliable instrument. The scoring system may be used in future Internet research. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  14. Accuracy and reliability of Chile's National Air Quality Information System for measuring particulate matter: Beta attenuation monitoring issue.

    PubMed

    Toro A, Richard; Campos, Claudia; Molina, Carolina; Morales S, Raul G E; Leiva-Guzmán, Manuel A

    2015-09-01

    A critical analysis of Chile's National Air Quality Information System (NAQIS) is presented, focusing on particulate matter (PM) measurement. This paper examines the complexity, availability and reliability of monitoring station information, the implementation of control systems, the quality assurance protocols of the monitoring station data and the reliability of the measurement systems in areas highly polluted by particulate matter. From information available on the NAQIS website, it is possible to confirm that the PM2.5 (PM10) data available on the site correspond to 30.8% (69.2%) of the total information available from the monitoring stations. There is a lack of information regarding the measurement systems used to quantify air pollutants, most of the available data registers contain gaps, almost all of the information is categorized as "preliminary information" and neither standard operating procedures (operational and validation) nor assurance audits or quality control of the measurements are reported. In contrast, events that cause saturation of the monitoring detectors located in northern and southern Chile have been observed using beta attenuation monitoring. In these cases, it can only be concluded that the PM content is equal to or greater than the saturation concentration registered by the monitors and that the air quality indexes obtained from these measurements are underestimated. This occurrence has been observed in 12 (20) public and private stations where PM2.5 (PM10) is measured. The shortcomings of the NAQIS data have important repercussions for the conclusions obtained from the data and for how the data are used. However, these issues represent opportunities for improving the system to widen its use, incorporate comparison protocols between equipment, install new stations and standardize the control system and quality assurance. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Intra- and Interobserver Reliability of Three Classification Systems for Hallux Rigidus.

    PubMed

    Dillard, Sarita; Schilero, Christina; Chiang, Sharon; Pham, Peter

    2018-04-18

    There are over ten classification systems currently used in the staging of hallux rigidus. This results in confusion and inconsistency with radiographic interpretation and treatment. The reliability of hallux rigidus classification systems has not yet been tested. The purpose of this study was to evaluate intra- and interobserver reliability using three commonly used classifications for hallux rigidus. Twenty-one plain radiograph sets were presented to ten ACFAS board-certified foot and ankle surgeons. Each physician classified each radiograph based on clinical experience and knowledge according to the Regnauld, Roukis, and Hattrup and Johnson classification systems. The two-way mixed single-measure consistency intraclass correlation was used to calculate intra- and interrater reliability. The intrarater reliability of individual sets for the Roukis and Hattrup and Johnson classification systems was "fair to good" (Roukis, 0.62±0.19; Hattrup and Johnson, 0.62±0.28), whereas the intrarater reliability of individual sets for the Regnauld system bordered between "fair to good" and "poor" (0.43±0.24). The interrater reliability of the mean classification was "excellent" for all three classification systems. Conclusions Reliable and reproducible classification systems are essential for treatment and prognostic implications in hallux rigidus. In our study, Roukis classification system had the best intrarater reliability. Although there are various classification systems for hallux rigidus, our results indicate that all three of these classification systems show reliability and reproducibility.

  16. Space Shuttle Program Primary Avionics Software System (PASS) Success Legacy - Quality and Reliability Date

    NASA Technical Reports Server (NTRS)

    Orr, James K.; Peltier, Daryl

    2010-01-01

    Thsi slide presentation reviews the avionics software system on board the space shuttle, with particular emphasis on the quality and reliability. The Primary Avionics Software System (PASS) provides automatic and fly-by-wire control of critical shuttle systems which executes in redundant computers. Charts given show the number of space shuttle flights vs time, PASS's development history, and other charts that point to the reliability of the system's development. The reliability of the system is also compared to predicted reliability.

  17. Unidata LDM-7: a Hybrid Multicast/unicast System for Highly Efficient and Reliable Real-Time Data Distribution

    NASA Astrophysics Data System (ADS)

    Emmerson, S. R.; Veeraraghavan, M.; Chen, S.; Ji, X.

    2015-12-01

    Results of a pilot deployment of a major new version of the Unidata Local Data Manager (LDM-7) are presented. The Unidata LDM was developed by the University Corporation for Atmospheric Research (UCAR) and comprises a suite of software for the distribution and local processing of data in near real-time. It is widely used in the geoscience community to distribute observational data and model output, most notably as the foundation of the Unidata Internet Data Distribution (IDD) system run by UCAR, but also in private networks operated by NOAA, NASA, USGS, etc. The current version, LDM-6, uses at least one unicast TCP connection per receiving host. With over 900 connections, the bit-rate of total outgoing IDD traffic from UCAR averages approximately 3.0 GHz, with peak data rates exceeding 6.6 GHz. Expected increases in data volume suggest that a more efficient distribution mechanism will be required in the near future. LDM-7 greatly reduces the outgoing bandwidth requirement by incorporating a recently-developed "semi-reliable" IP multicast protocol while retaining the unicast TCP mechanism for reliability. During the summer of 2015, UCAR and the University of Virginia conducted a pilot deployment of the Unidata LDM-7 among U.S. university participants with access to the Internet2 network. Results of this pilot program, along with comparisons to the existing Unidata LDM-6 system, are presented.

  18. Technology verification phase. Dynamic isotope power system. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Halsey, D.G.

    1982-03-10

    The Phase I requirements of the Kilowatt Isotope Power System (KIPS) program were to make a detailed Flight System Conceptual Design (FSCD) for an isotope fueled organic Rankine cycle power system and to build and test a Ground Demonstration System (GDS) which simulated as closely as possible the operational characteristics of the FSCD. The activities and results of Phase II, the Technology Verification Phase, of the program are reported. The objectives of this phase were to increase system efficiency to 18.1% by component development, to demonstrate system reliability by a 5000 h endurance test and to update the flight systemmore » design. During Phase II, system performance was improved from 15.1% to 16.6%, an endurance test of 2000 h was performed while the flight design analysis was limited to a study of the General Purpose Heat Source, a study of the regenerator manufacturing technique and analysis of the hardness of the system to a laser threat. It was concluded from these tests that the GDS is basically prototypic of a flight design; all components necessary for satisfactory operation were demonstrated successfully at the system level; over 11,000 total h of operation without any component failure attested to the inherent reliability of this type of system; and some further development is required, specifically in the area of performance. (LCL)« less

  19. The root coverage esthetic score: Intra-examiner reliability among students and faculty at tufts university school of dental medicine.

    PubMed

    Isaia, Federica; Gyurko, Robert; Roomian, Tamar C; Hawley, Charles E

    2018-04-06

    The Root Coverage Esthetic Score (RES) was published in 2009 as an esthetic scoring system to measure visible final outcomes of root coverage procedures performed on Miller I and II recession defects. The aim of this study was to evaluate the intra-examiner, intra-group, and inter-examiner reliability of the (Root Coverage Esthetic Score) RES when used among periodontal faculty, post-graduate students in periodontology, and pre-doctoral DMD students when using the RES at Tufts University School of Dental Medicine (TUSDM). Thirty-three participants (12 second year DMD students, 11 periodontal residents, and 10 faculty members) were assembled to evaluate 25 baseline and 6-months post-treatment outcomes of mucogingival surgeries using the RES. Each projection was shown for 30 seconds during which the participants were asked to use the RES scoring system to evaluate the surgical outcomes. The results were then recorded on a standardized worksheet grid. To test intra-examiner reliability, 7 of the 25 projections were shown twice. Intra-examiner reliability and inter-examiner reliability were assessed using intraclass correlation coefficient using a two-way mixed effects model, and stratified by education level. PG residents had the highest tendency to agree with each other with an interclass correlation (ICC) of 0.53 (95%CI 0.36 - 0.74). DMD students had an ICC: 0.51 (95%CI: 0.33 - 0.75), and PG faculty members produced an ICC: 0.41 (95%CI: 0.24 - 0.64). There was no statistically significant difference in ICC among the three groups of participants (Kruskal-Wallis test, P = 0.2440). When the data for each RES element were then combined, the mean ICC for the total interrater agreement for RES was 0.48 (95% CI: 0.32-0.71). This corresponds to an overall moderate agreement among all participants using the RES to evaluate the 25 surgical outcomes. The intra-examiner reliability within each of the three groups was quite high. The highest mean ICC was produced by the PG Faculty (0.908). The mean ICCs for PG residents was 0.867, and the mean ICC for DMD students was 0.855. The Kruskal-Wallis test (p = 0.46) failed to find any statistical difference in intra-examiner reliability between the three groups of participants CONCLUSIONS: The RES is a "moderately" reliable scoring system for mucogingival treatments in a dental school setting and can be used even by operators with different level of periodontal experience. This scoring system can be repeated by the same examiner obtaining reliable results. This article is protected by copyright. All rights reserved. © 2018 American Academy of Periodontology.

  20. Total Dose Effects on Single Event Transients in Linear Bipolar Systems

    NASA Technical Reports Server (NTRS)

    Buchner, Stephen; McMorrow, Dale; Bernard, Muriel; Roche, Nicholas; Dusseau, Laurent

    2008-01-01

    Single Event Transients (SETs) originating in linear bipolar integrated circuits are known to undermine the reliability of electronic systems operating in the radiation environment of space. Ionizing particle radiation produces a variety of SETs in linear bipolar circuits. The extent to which these SETs threaten system reliability depends on both their shapes (amplitude and width) and their threshold energies. In general, SETs with large amplitudes and widths are the most likely to propagate from a bipolar circuit's output through a subsystem. The danger these SET pose is that, if they become latched in a follow-on circuit, they could cause an erroneous system response. Long-term exposure of linear bipolar circuits to particle radiation produces total ionizing dose (TID) and/or displacement damage dose (DDD) effects that are characterized by a gradual degradation in some of the circuit's electrical parameters. For example, an operational amplifier's gain-bandwidth product is reduced by exposure to ionizing radiation, and it is this reduction that contributes to the distortion of the SET shapes. In this paper, we compare SETs produced in a pristine LM124 operational amplifier with those produced in one exposed to ionizing radiation for three different operating configurations - voltage follower (VF), inverter with gain (IWG), and non-inverter with gain (NIWG). Each configuration produces a unique set of transient shapes that change following exposure to ionizing radiation. An important finding is that the changes depend on operating configuration; some SETs decrease in amplitude, some remain relatively unchanged, some become narrower and some become broader.

  1. A fully automated FTIR system for remote sensing of greenhouse gases in the tropics

    NASA Astrophysics Data System (ADS)

    Geibel, M. C.; Gerbig, C.; Feist, D. G.

    2010-07-01

    This article introduces a new fully automated FTIR system that is part of the Total Carbon Column Observing Network. It will provide continuous ground-based measurements of column-averaged volume mixing ratio for CO2, CH4 and several other greenhouse gases in the tropics. Housed in a 20-foot shipping container it was developed as a transportable system that could be deployed almost anywhere in the world. We describe the automation concept which relies on three autonomous subsystems and their interaction. Crucial components like a sturdy and reliable solar tracker dome are described in detail. First results of total column measurements at Jena, Germany show that the instrument works well and can provide diurnal as well as seasonal cycle for CO2. Instrument line shape measurements with an HCl cell suggest that the instrument stays well-aligned over several months. After a short test campaign for side by side intercomaprison with an existing TCCON instrument in Australia, the system will be transported to its final destination Ascension Island.

  2. Trajectory correction propulsion for TOPS

    NASA Technical Reports Server (NTRS)

    Long, H. R.; Bjorklund, R. A.

    1972-01-01

    A blowdown-pressurized hydrazine propulsion system was selected to provide trajectory correction impulse for outer planet flyby spacecraft as the result of cost/mass/reliability tradeoff analyses. Present hydrazine component and system technology and component designs were evaluated for application to the Thermoelectric Outer Planet Spacecraft (TOPS); while general hydrazine technology was adequate, component design changes were deemed necessary for TOPS-type missions. A prototype hydrazine propulsion system was fabricated and fired nine times for a total of 1600 s to demonstrate the operation and performance of the TOPS propulsion configuration. A flight-weight trajectory correction propulsion subsystem (TCPS) was designed for the TOPS based on actual and estimated advanced components.

  3. Reliable and Affordable Control Systems Active Combustor Pattern Factor Control

    NASA Technical Reports Server (NTRS)

    McCarty, Bob; Tomondi, Chris; McGinley, Ray

    2004-01-01

    Active, closed-loop control of combustor pattern factor is a cooperative effort between Honeywell (formerly AlliedSignal) Engines and Systems and the NASA Glenn Research Center to reduce emissions and turbine-stator vane temperature variations, thereby enhancing engine performance and life, and reducing direct operating costs. Total fuel flow supplied to the engine is established by the speed/power control, but the distribution to individual atomizers will be controlled by the Active Combustor Pattern Factor Control (ACPFC). This system consist of three major components: multiple, thin-film sensors located on the turbine-stator vanes; fuel-flow modulators for individual atomizers; and control logic and algorithms within the electronic control.

  4. Continuous recording of pulmonary artery pressure in unrestricted subjects.

    PubMed Central

    Ikram, H; Richards, A M; Hamilton, E J; Nicholls, M G

    1984-01-01

    Continuous ambulatory pulmonary artery pressures were recorded using a conventional No 5 French Goodale-Lubin filled catheter linked to the Oxford Medilog system of a portable transducer-perfusion unit and miniaturised recorder. Data retrieval and analysis were performed using a PB2 Medilog playback unit linked to a PDP 11 computer system. The total system has a frequency response linear to 8 Hz allowing accurate pressure recording over the full range of heart rates. Ten recordings in 10 patients yielded artefact free data for 80% or more of the recorded period. This inexpensive reliable method allows pulmonary artery pressures to be recorded in unrestricted subjects. Images PMID:6704262

  5. Validation of the Persian version of the dysphagia handicap index in patients with neurological disorders

    PubMed Central

    Barzegar-Bafrooei, Ebrahim; Bakhtiary, Jalal; Khatoonabadi, Ahmad Reza; Fatehi, Farzad; Maroufizadeh, Saman; Fathali, Mojtaba

    2016-01-01

    Background: Dysphagia as a common condition affecting many aspects of the patient’s life. The Dysphagia Handicap Index (DHI) is a reliable self-reported questionnaire developed specifically to measure the impact of dysphagia on the patient’s quality of life. The aim of this study was to translate the questionnaire to Persian and to measure its validity and reliability in patients with neurogenic oropharyngeal dysphagia. Methods: A formal forward-backward translation of DHI was performed based on the guidelines for the cross-cultural adaptation of self-report measures. A total of 57 patients with neurogenic dysphagia who were referred to the neurology clinics of Tehran University of Medical Sciences, Iran, participated in this study. Internal consistency reliability of the DHI was examined using Cronbach’s alpha, and test-retest reliability of the scale was evaluated using intraclass correlation coefficient (ICC). Results: The internal consistency of the Persian DHI (P-DHI) was considered to be good; Cronbach’s alpha coefficient for the total P-DHI was 0.88. The test-retest reliability for the total and three subscales of the P-DHI ranged from 0.95 to 0.98 using ICC. Conclusion: The P-DHI demonstrated a good reliability, and it can be a valid instrument for evaluating the dysphagia effects on quality of life among Persian language population. PMID:27648173

  6. Evaluation of the Early Childhood Oral Health Impact Scale in an Australian preschool child population.

    PubMed

    Arrow, P; Klobas, E

    2015-09-01

    Early childhood caries has significant impacts on children and their families. The Early Childhood Oral Health Impact Scale (ECOHIS) is an instrument for capturing the complex dimensions of preschool children's oral health. This study aimed to evaluate the reliability and validity of the instrument among Australian preschool children. Parents/children dyads (n = 286) participating in a treatment trial on early childhood caries completed the scale at baseline, and 33 parents repeated the questionnaire 2-3 weeks later. The validity and reliability of the ECOHIS was determined using tests for convergent and discriminant validity, internal reliability of the instrument and test-retest reliability. Scale impacts were strongly correlated with global oral health ratings (Spearman's correlations; r = 0.51, total score; r = 0.43, child impact; and r = 0.49, family impact; p < 0.001). The scale was significantly associated with children's caries experience, p < 0.001. Cronbach's alpha values were 0.87, 0.89 and 0.74 for the total, the child and the family domains, respectively. Test-retest reliability was 0.92, 0.89 and 0.78 for the total, child and family domains, respectively. The scale demonstrated acceptable validity and reliability for assessing the impact of early childhood caries among Australian preschool children. © 2015 Australian Dental Association.

  7. A new fully automated FTIR system for total column measurements of greenhouse gases

    NASA Astrophysics Data System (ADS)

    Geibel, M. C.; Gerbig, C.; Feist, D. G.

    2010-10-01

    This article introduces a new fully automated FTIR system that is part of the Total Carbon Column Observing Network (TCCON). It will provide continuous ground-based measurements of column-averaged volume mixing ratio for CO2, CH4 and several other greenhouse gases in the tropics. Housed in a 20-foot shipping container it was developed as a transportable system that could be deployed almost anywhere in the world. We describe the automation concept which relies on three autonomous subsystems and their interaction. Crucial components like a sturdy and reliable solar tracker dome are described in detail. The automation software employs a new approach relying on multiple processes, database logging and web-based remote control. First results of total column measurements at Jena, Germany show that the instrument works well and can provide parts of the diurnal as well as seasonal cycle for CO2. Instrument line shape measurements with an HCl cell suggest that the instrument stays well-aligned over several months. After a short test campaign for side by side intercomaprison with an existing TCCON instrument in Australia, the system will be transported to its final destination Ascension Island.

  8. Modified Y-TZP Core Design Improves All-ceramic Crown Reliability

    PubMed Central

    Silva, N.R.F.A.; Bonfante, E.A.; Rafferty, B.T.; Zavanelli, R.A.; Rekow, E.D.; Thompson, V.P.; Coelho, P.G.

    2011-01-01

    This study tested the hypothesis that all-ceramic core-veneer system crown reliability is improved by modification of the core design. We modeled a tooth preparation by reducing the height of proximal walls by 1.5 mm and the occlusal surface by 2.0 mm. The CAD-based tooth preparation was replicated and positioned in a dental articulator for core and veneer fabrication. Standard (0.5 mm uniform thickness) and modified (2.5 mm height lingual and proximal cervical areas) core designs were produced, followed by the application of veneer porcelain for a total thickness of 1.5 mm. The crowns were cemented to 30-day-aged composite dies and were either single-load-to-failure or step-stress-accelerated fatigue-tested. Use of level probability plots showed significantly higher reliability for the modified core design group. The fatigue fracture modes were veneer chipping not exposing the core for the standard group, and exposing the veneer core interface for the modified group. PMID:21057036

  9. Photovoltaic systems sizing for Algeria

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arab, A.H.; Driss, B.A.; Amimeur, R.

    1995-02-01

    The purpose of this work is to develop an optimization method applicable to stand-alone photovoltaic systems as a function of its reliability. For a given loss-of-load probability (LLP), there are many combinations of battery capacity and photovoltaic array peak power. The problem consists in determining the couple which corresponds to a minimum total system cost. The method has been applied to various areas all over Algeria taking into account various climatic zones. The parameter used to define the different climatic zones is the clearness index KT for all the considered sites. The period of the simulation system is 10 years.more » 5 refs., 4 figs., 5 tabs.« less

  10. Feedback control of the lower hybrid power deposition profile on Tore Supra

    NASA Astrophysics Data System (ADS)

    Barana, O.; Mazon, D.; Laborde, L.; Turco, F.

    2007-07-01

    The Tore Supra facility is well suited to study ITER relevant topics such as the real-time control of plasma current and the sustaining of steady-state discharges. This work describes a tool that was recently developed and implemented on Tore Supra to control in real time, by means of the direct knowledge of the suprathermal electron local emission profile, the width of the lower hybrid power deposition profile. This quantity can be considered to some extent equivalent to the width of the plasma current density profile in case of fully non-inductive discharges. This system takes advantage of an accurate hard x-ray diagnostics, of an efficient lower hybrid additional heating and of a reliable real-time communication network. The successful experiments carried out to test the system employed, as actuators, the parallel refractive index n// and the total power PLH. The control of the suprathermal electron local emission profile through n// was also integrated with the feedback control of the total plasma current IP with PLH and of the loop voltage Vloop with the central solenoid flux. These results demonstrate that the system is robust, reliable and able to counterbalance destabilizing events. This tool can be effectively used in the future in fully non-inductive discharges to improve the MHD stability and to maintain internal transport barriers or lower hybrid enhanced performance modes. The real-time control of the lower hybrid power deposition profile could also be used in conjunction with the electron-cyclotron radiofrequency heating for synergy studies.

  11. Reliability and Validity of a Japanese-language and Culturally Adapted Version of the Musculoskeletal Tumor Society Scoring System for the Lower Extremity.

    PubMed

    Iwata, Shintaro; Uehara, Kosuke; Ogura, Koichi; Akiyama, Toru; Shinoda, Yusuke; Yonemoto, Tsukasa; Kawai, Akira

    2016-09-01

    The Musculoskeletal Tumor Society (MSTS) scoring system is a widely used functional evaluation tool for patients treated for musculoskeletal tumors. Although the MSTS scoring system has been validated in English and Brazilian Portuguese, a Japanese version of the MSTS scoring system has not yet been validated. We sought to determine whether a Japanese-language translation of the MSTS scoring system for the lower extremity had (1) sufficient reliability and internal consistency, (2) adequate construct validity, and (3) reasonable criterion validity compared with the Toronto Extremity Salvage Score (TESS) and SF-36 using psychometric analysis. The Japanese version of the MSTS scoring system was developed using accepted guidelines, which included translation of the English version of the MSTS into Japanese by five native Japanese bilingual musculoskeletal oncology surgeons and integrated into one document. One hundred patients with a diagnosis of intermediate or malignant bone or soft tissue tumors located in the lower extremity and who had undergone tumor resection with or without reconstruction or amputation participated in this study. Reliability was evaluated by test-retest analysis, and internal consistency was established by Cronbach's alpha coefficient. Construct validity was evaluated using the principal factor analysis and Akaike information criterion network. Criterion validity was evaluated by comparing the MSTS scoring system with the TESS and SF-36. Test-retest analysis showed a high intraclass correlation coefficient (0.92; 95% CI, 0.88-0.95), indicating high reliability of the Japanese version of the MSTS scoring system, although a considerable ceiling effect was observed, with 23 patients (23%) given the maximum score. Cronbach's alpha coefficient was 0.87 (95% CI, 0.82-0.90), suggesting a high level of internal consistency. Factor analysis revealed that all items had high loading values and communalities; we identified a central role for the items "walking" and "gait" according to the Akaike information criterion network. The total MSTS score was correlated with that of the TESS (r = 0.81; 95% CI, 0.73-0.87; p < 0.001) and the physical component summary and physical functioning of the SF-36. The Japanese-language translation of the MSTS scoring system for the lower extremity has sufficient reliability and reasonable validity. Nevertheless, the observation of a ceiling effect suggests poor ability of this system to discriminate from among patients who have a high level of function.

  12. Development of the Connecticut Airway Risk Evaluation (CARE) system to improve handoff communication in pediatric patients with tracheotomy.

    PubMed

    Lawrason Hughes, Amy; Murray, Nicole; Valdez, Tulio A; Kelly, Raeanne; Kavanagh, Katherine

    2014-01-01

    National attention has focused on the importance of handoffs in medicine. Our practice during airway patient handoffs is to communicate a patient-specific emergency plan for airway reestablishment; patients who are not intubatable by standard means are at higher risk for failure. There is currently no standard classification system describing airway risk in tracheotomized patients. To introduce and assess the interrater reliability of a simple airway risk classification system, the Connecticut Airway Risk Evaluation (CARE) system. We created a novel classification system, the CARE system, based on ease of intubation and the need for ventilation: group 1, easily intubatable; group 2, intubatable with special equipment and/or maneuvers; group 3, not intubatable. A "v" was appended to any group number to indicate the need for mechanical ventilation. We performed a retrospective medical chart review of patients aged 0 to 18 years who were undergoing tracheotomy at our tertiary care pediatric hospital between January 2000 and April 2011. INTERVENTIONS Each patient's medical history, including airway disease and means of intubation, was reviewed by 4 raters. Patient airways were separately rated as CARE groups 1, 2, or 3, each group with or without a v appended, as appropriate, based on the available information. After the patients were assigned to an airway group by each of the 4 raters, the interrater reliability was calculated to determine the ease of use of the rating system. We identified complete data for 155 of 169 patients (92%), resulting in a total of 620 ratings. Based on the patient's ease of intubation, raters categorized tracheotomized patients into group 1 (70%, 432 of 620); group 2 (25%, 157 of 620); or group 3 (5%, 29 of 620), each with a v appended if appropriate. The interrater reliability was κ = 0.95. We propose an airway risk classification system for tracheotomized patients, CARE, that has high interrater reliability and is easy to use and interpret. As medical providers and national organizations place more focus on improvements in interprovider communication, the creation of an airway handoff tool is integral to improving patient safety and airway management strategies following tracheotomy complications.

  13. Evaluation of reliability modeling tools for advanced fault tolerant systems

    NASA Technical Reports Server (NTRS)

    Baker, Robert; Scheper, Charlotte

    1986-01-01

    The Computer Aided Reliability Estimation (CARE III) and Automated Reliability Interactice Estimation System (ARIES 82) reliability tools for application to advanced fault tolerance aerospace systems were evaluated. To determine reliability modeling requirements, the evaluation focused on the Draper Laboratories' Advanced Information Processing System (AIPS) architecture as an example architecture for fault tolerance aerospace systems. Advantages and limitations were identified for each reliability evaluation tool. The CARE III program was designed primarily for analyzing ultrareliable flight control systems. The ARIES 82 program's primary use was to support university research and teaching. Both CARE III and ARIES 82 were not suited for determining the reliability of complex nodal networks of the type used to interconnect processing sites in the AIPS architecture. It was concluded that ARIES was not suitable for modeling advanced fault tolerant systems. It was further concluded that subject to some limitations (the difficulty in modeling systems with unpowered spare modules, systems where equipment maintenance must be considered, systems where failure depends on the sequence in which faults occurred, and systems where multiple faults greater than a double near coincident faults must be considered), CARE III is best suited for evaluating the reliability of advanced tolerant systems for air transport.

  14. Eye Movement Analysis and Cognitive Assessment. The Use of Comparative Visual Search Tasks in a Non-immersive VR Application.

    PubMed

    Rosa, Pedro J; Gamito, Pedro; Oliveira, Jorge; Morais, Diogo; Pavlovic, Matthew; Smyth, Olivia; Maia, Inês; Gomes, Tiago

    2017-03-23

    An adequate behavioral response depends on attentional and mnesic processes. When these basic cognitive functions are impaired, the use of non-immersive Virtual Reality Applications (VRAs) can be a reliable technique for assessing the level of impairment. However, most non-immersive VRAs use indirect measures to make inferences about visual attention and mnesic processes (e.g., time to task completion, error rate). To examine whether the eye movement analysis through eye tracking (ET) can be a reliable method to probe more effectively where and how attention is deployed and how it is linked with visual working memory during comparative visual search tasks (CVSTs) in non-immersive VRAs. The eye movements of 50 healthy participants were continuously recorded while CVSTs, selected from a set of cognitive tasks in the Systemic Lisbon Battery (SLB). Then a VRA designed to assess of cognitive impairments were randomly presented. The total fixation duration, the number of visits in the areas of interest and in the interstimulus space, along with the total execution time was significantly different as a function of the Mini Mental State Examination (MMSE) scores. The present study demonstrates that CVSTs in SLB, when combined with ET, can be a reliable and unobtrusive method for assessing cognitive abilities in healthy individuals, opening it to potential use in clinical samples.

  15. Bulk electric system reliability evaluation incorporating wind power and demand side management

    NASA Astrophysics Data System (ADS)

    Huang, Dange

    Electric power systems are experiencing dramatic changes with respect to structure, operation and regulation and are facing increasing pressure due to environmental and societal constraints. Bulk electric system reliability is an important consideration in power system planning, design and operation particularly in the new competitive environment. A wide range of methods have been developed to perform bulk electric system reliability evaluation. Theoretically, sequential Monte Carlo simulation can include all aspects and contingencies in a power system and can be used to produce an informative set of reliability indices. It has become a practical and viable tool for large system reliability assessment technique due to the development of computing power and is used in the studies described in this thesis. The well-being approach used in this research provides the opportunity to integrate an accepted deterministic criterion into a probabilistic framework. This research work includes the investigation of important factors that impact bulk electric system adequacy evaluation and security constrained adequacy assessment using the well-being analysis framework. Load forecast uncertainty is an important consideration in an electrical power system. This research includes load forecast uncertainty considerations in bulk electric system reliability assessment and the effects on system, load point and well-being indices and reliability index probability distributions are examined. There has been increasing worldwide interest in the utilization of wind power as a renewable energy source over the last two decades due to enhanced public awareness of the environment. Increasing penetration of wind power has significant impacts on power system reliability, and security analyses become more uncertain due to the unpredictable nature of wind power. The effects of wind power additions in generating and bulk electric system reliability assessment considering site wind speed correlations and the interactive effects of wind power and load forecast uncertainty on system reliability are examined. The concept of the security cost associated with operating in the marginal state in the well-being framework is incorporated in the economic analyses associated with system expansion planning including wind power and load forecast uncertainty. Overall reliability cost/worth analyses including security cost concepts are applied to select an optimal wind power injection strategy in a bulk electric system. The effects of the various demand side management measures on system reliability are illustrated using the system, load point, and well-being indices, and the reliability index probability distributions. The reliability effects of demand side management procedures in a bulk electric system including wind power and load forecast uncertainty considerations are also investigated. The system reliability effects due to specific demand side management programs are quantified and examined in terms of their reliability benefits.

  16. Time Exceedances for High Intensity Solar Proton Fluxes

    NASA Technical Reports Server (NTRS)

    Xapsos, Michael A.; Stauffer, Craig A.; Jordan, Thomas M.; Adam, James H., Jr.; Dietrich, William F.

    2011-01-01

    A model is presented for times during a space mission that specified solar proton flux levels are exceeded. This includes both total time and continuous time periods during missions. Results for the solar maximum and solar minimum phases of the solar cycle are presented and compared for a broad range of proton energies and shielding levels. This type of approach is more amenable to reliability analysis for spacecraft systems and instrumentation than standard statistical models.

  17. Periods of High Intensity Solar Proton Flux

    NASA Technical Reports Server (NTRS)

    Xapsos, Michael A.; Stauffer, Craig A.; Jordan, Thomas M.; Adams, James H.; Dietrich, William F.

    2012-01-01

    Analysis is presented for times during a space mission that specified solar proton flux levels are exceeded. This includes both total time and continuous time periods during missions. Results for the solar maximum and solar minimum phases of the solar cycle are presented and compared for a broad range of proton energies and shielding levels. This type of approach is more amenable to reliability analysis for spacecraft systems and instrumentation than standard statistical models.

  18. Design of a radiation tolerant system for total ionizing dose monitoring using floating gate and RadFET dosimeters

    NASA Astrophysics Data System (ADS)

    Ferraro, R.; Danzeca, S.; Brucoli, M.; Masi, A.; Brugger, M.; Dilillo, L.

    2017-04-01

    The need for upgrading the Total Ionizing Dose (TID) measurement resolution of the current version of the Radiation Monitoring system for the LHC complex has driven the research of new TID sensors. The sensors being developed nowadays can be defined as Systems On Chip (SOC) with both analog and digital circuitries embedded in the same silicon. A radiation tolerant TID Monitoring System (TIDMon) has been designed to allow the placement of the entire dosimeter readout electronics in very harsh environments such as calibration rooms and even in the mixed radiation field such as the one of the LHC complex. The objective of the TIDMon is to measure the effect of the TID on the new prototype of Floating Gate Dosimeter (FGDOS) without using long cables and with a reliable measurement system. This work introduces the architecture of the TIDMon, the radiation tolerance techniques applied on the controlling electronics as well as the design choices adopted for the system. Finally, results of several tests of TIDMon under different radiation environments such as gamma rays or mixed radiation field at CHARM are presented.

  19. Validation of the Behavioral Risk Factor Surveillance System Sleep Questions

    PubMed Central

    Jungquist, Carla R.; Mund, Jaime; Aquilina, Alan T.; Klingman, Karen; Pender, John; Ochs-Balcom, Heather; van Wijngaarden, Edwin; Dickerson, Suzanne S.

    2016-01-01

    Study Objective: Sleep problems may constitute a risk for health problems, including cardiovascular disease, depression, diabetes, poor work performance, and motor vehicle accidents. The primary purpose of this study was to assess the validity of the current Behavioral Risk Factor Surveillance System (BRFSS) sleep questions by establishing the sensitivity and specificity for detection of sleep/ wake disturbance. Methods: Repeated cross-sectional assessment of 300 community dwelling adults over the age of 18 who did not wear CPAP or oxygen during sleep. Reliability and validity testing of the BRFSS sleep questions was performed comparing to BFRSS responses to data from home sleep study, actigraphy for 14 days, Insomnia Severity Index, Epworth Sleepiness Scale, and PROMIS-57. Results: Only two of the five BRFSS sleep questions were found valid and reliable in determining total sleep time and excessive daytime sleepiness. Conclusions: Refinement of the BRFSS questions is recommended. Citation: Jungquist CR, Mund J, Aquilina AT, Klingman K, Pender J, Ochs-Balcom H, van Wijngaarden E, Dickerson SS. Validation of the behavioral risk factor surveillance system sleep questions. J Clin Sleep Med 2016;12(3):301–310. PMID:26446246

  20. Video Monitoring a Simulation-Based Quality Improvement Program in Bihar, India.

    PubMed

    Dyer, Jessica; Spindler, Hilary; Christmas, Amelia; Shah, Malay Bharat; Morgan, Melissa; Cohen, Susanna R; Sterne, Jason; Mahapatra, Tanmay; Walker, Dilys

    2018-04-01

    Simulation-based training has become an accepted clinical training andragogy in high-resource settings with its use increasing in low-resource settings. Video recordings of simulated scenarios are commonly used by facilitators. Beyond using the videos during debrief sessions, researchers can also analyze the simulation videos to quantify technical and nontechnical skills during simulated scenarios over time. Little is known about the feasibility and use of large-scale systems to video record and analyze simulation and debriefing data for monitoring and evaluation in low-resource settings. This manuscript describes the process of designing and implementing a large-scale video monitoring system. Mentees and Mentors were consented and all simulations and debriefs conducted at 320 Primary Health Centers (PHCs) were video recorded. The system design, number of video recordings, and inter-rater reliability of the coded videos were assessed. The final dataset included a total of 11,278 videos. Overall, a total of 2,124 simulation videos were coded and 183 (12%) were blindly double-coded. For the double-coded sample, the average inter-rater reliability (IRR) scores were 80% for nontechnical skills, and 94% for clinical technical skills. Among 4,450 long debrief videos received, 216 were selected for coding and all were double-coded. Data quality of simulation videos was found to be very good in terms of recorded instances of "unable to see" and "unable to hear" in Phases 1 and 2. This study demonstrates that video monitoring systems can be effectively implemented at scale in resource limited settings. Further, video monitoring systems can play several vital roles within program implementation, including monitoring and evaluation, provision of actionable feedback to program implementers, and assurance of program fidelity.

  1. Reliability and concurrent validity of the Dutch hip and knee replacement expectations surveys

    PubMed Central

    2010-01-01

    Background Preoperative expectations of outcome of total hip and knee arthroplasty are important determinants of patients' satisfaction and functional outcome. Aims of the study were (1) to translate the Hospital for Special Surgery Hip Replacement Expectations Survey and Knee Replacement Expectations Survey into Dutch and (2) to study test-retest reliability and concurrent validity. Methods Patients scheduled for total hip (N = 112) or knee replacement (N = 101) were sent the Dutch Expectations Surveys twice with a 2 week interval to determine test-retest reliability. To determine concurrent validity, the Expectation WOMAC was sent. Results The results for the Dutch Hip Replacement Expectations Survey revealed good test-retest reliability (ICC 0.87), no bias and good internal consistency (alpha 0.86) (N = 72). The correlation between the Hip Expectations Score and the Expectation WOMAC score was 0.59 (N = 86). The results for the Dutch Knee Replacement Expectations Survey revealed good test-retest reliability (ICC 0.79), no bias and good internal consistency (alpha 0.91) (N = 46). The correlation with the Expectation WOMAC score was 0.52 (N = 57). Conclusions Both Dutch Expectations Surveys are reliable instruments to determine patients' expectations before total hip or knee arthroplasty. As for concurrent validity, the correlation between both surveys and the Expectation WOMAC was moderate confirming that the same construct was determined. However, patients scored systematically lower on the Expectation WOMAC compared to the Dutch Expectation Surveys. Research on patients' expectations before total hip and knee replacement has only been performed in a limited amount of countries. With the Dutch Expectations Surveys it is now possible to determine patients' expectations in another culture and healthcare setting. PMID:20958990

  2. Reliability and concurrent validity of the Dutch hip and knee replacement expectations surveys.

    PubMed

    van den Akker-Scheek, Inge; van Raay, Jos J A M; Reininga, Inge H F; Bulstra, Sjoerd K; Zijlstra, Wiebren; Stevens, Martin

    2010-10-19

    Preoperative expectations of outcome of total hip and knee arthroplasty are important determinants of patients' satisfaction and functional outcome. Aims of the study were (1) to translate the Hospital for Special Surgery Hip Replacement Expectations Survey and Knee Replacement Expectations Survey into Dutch and (2) to study test-retest reliability and concurrent validity. Patients scheduled for total hip (N = 112) or knee replacement (N = 101) were sent the Dutch Expectations Surveys twice with a 2 week interval to determine test-retest reliability. To determine concurrent validity, the Expectation WOMAC was sent. The results for the Dutch Hip Replacement Expectations Survey revealed good test-retest reliability (ICC 0.87), no bias and good internal consistency (alpha 0.86) (N = 72). The correlation between the Hip Expectations Score and the Expectation WOMAC score was 0.59 (N = 86). The results for the Dutch Knee Replacement Expectations Survey revealed good test-retest reliability (ICC 0.79), no bias and good internal consistency (alpha 0.91) (N = 46). The correlation with the Expectation WOMAC score was 0.52 (N = 57). Both Dutch Expectations Surveys are reliable instruments to determine patients' expectations before total hip or knee arthroplasty. As for concurrent validity, the correlation between both surveys and the Expectation WOMAC was moderate confirming that the same construct was determined. However, patients scored systematically lower on the Expectation WOMAC compared to the Dutch Expectation Surveys. Research on patients' expectations before total hip and knee replacement has only been performed in a limited amount of countries. With the Dutch Expectations Surveys it is now possible to determine patients' expectations in another culture and healthcare setting.

  3. [Development and validation of the Korean patient safety culture scale for nursing homes].

    PubMed

    Yoon, Sook Hee; Kim, Byungsoo; Kim, Se Young

    2013-06-01

    The purpose of this study was to develop a tool to evaluate patient safety culture in nursing homes and to test its validity and reliability. A preliminary tool was developed through interviews with focus group, content validity tests, and a pilot study. A nationwide survey was conducted from February to April, 2011, using self-report questionnaires. Participants were 982 employees in nursing homes. Data were analyzed using Cronbach's alpha, item analysis, factor analysis, and multitrait/multi-Item analysis. From the results of the analysis, 27 final items were selected from 49 items on the preliminary tool. Items with low correlation with total scale were excluded. The 4 factors sorted by factor analysis contributed 63.4% of the variance in the total scale. The factors were labeled as leadership, organizational system, working attitude, management practice. Cronbach's alpha for internal consistency was .95 and the range for the 4 factors was from .86 to .93. The results of this study indicate that the Korean Patient Safety Culture Scale has reliability and validity and is suitable for evaluation of patient safety culture in Korean nursing homes.

  4. A census of the asteroid belt

    NASA Technical Reports Server (NTRS)

    Tedesco, E. F.; Veeder, G. J.

    1991-01-01

    Observations obtained by the Infrared Astronomical Satellite (IRAS) during its ten month mission in 1983 were originally processed by the Asteroid Data Analysis System (ADAS) to search for 3453 asteroids with known orbital elements as of September 1985. A total of 1811 had one or more observations of sufficient reliability to be accepted. These results were released in October 1986. Recently IRAS data were reprocessed to increase both the number of recognized asteroid observations and their reliability. As input 7311 asteroids were used with known orbital elements as of December 1990. This processor is referred to as the IRAS Minor Planet Survey (IMPS). As of April 1991 approximately 3000 asteroids had been identified with one or more acceptable observations. These results were used to derive the total number of asteroids with diameters greater than 1 km. In addition to being an interesting piece of information in itself these size-frequency distributions produce bias-correction factors which, for example, will be used in investigations of the physical properties of asteroid dynamical families and to estimate the distribution of the taxonomic classes as a function of heliocentric distance.

  5. System and Software Reliability (C103)

    NASA Technical Reports Server (NTRS)

    Wallace, Dolores

    2003-01-01

    Within the last decade better reliability models (hardware. software, system) than those currently used have been theorized and developed but not implemented in practice. Previous research on software reliability has shown that while some existing software reliability models are practical, they are no accurate enough. New paradigms of development (e.g. OO) have appeared and associated reliability models have been proposed posed but not investigated. Hardware models have been extensively investigated but not integrated into a system framework. System reliability modeling is the weakest of the three. NASA engineers need better methods and tools to demonstrate that the products meet NASA requirements for reliability measurement. For the new models for the software component of the last decade, there is a great need to bring them into a form that they can be used on software intensive systems. The Statistical Modeling and Estimation of Reliability Functions for Systems (SMERFS'3) tool is an existing vehicle that may be used to incorporate these new modeling advances. Adapting some existing software reliability modeling changes to accommodate major changes in software development technology may also show substantial improvement in prediction accuracy. With some additional research, the next step is to identify and investigate system reliability. System reliability models could then be incorporated in a tool such as SMERFS'3. This tool with better models would greatly add value in assess in GSFC projects.

  6. [Validation and reliability of Turkish Singing Voice Handicap index].

    PubMed

    Denizoğlu, İsmail İlter; Şahin, Mustafa; Kazancıoğlu, Alper; Dağdelen, Zibelhan; Akdeniz, Serap; Oğuz, Haldun; Kılıç, Mehmet Akif; Yücedağ, Aslı; Öğüt, Mehmet Fatih

    2016-01-01

    This study aims to constitute a valid and reliable Turkish version of the original Singing Voice Handicap Index. An authorized committee assessed the reliability and validity of the content, scope, and language of the original Singing Voice Handicap Index which underwent a back translation process. The Turkish version of the questionnaire was answered twice with a 7 to 10-day interval by two singing voice groups with or without singing voice problems. The reliability and validity analyses were performed based on these answers. Of a total of 123 individuals (64 females, 59 males; mean age 26.2±7.3 years), 81 were without a voice pathology and 42 were with a voice pathology. The total Cronbach's alpha coefficient was 0.917. The item-total correlations ranged between 0.51 and 0.89. The weighted kappa values of test-retest correlation values of the items were 0.82-0.91. The Cronbach's alpha values of two part of the questionnaire based on the split-half method were 0.89 and 0.84. The mean total scale scores were 21.8±18.5 and 53.6±28.9 in normal and pathology groups, respectively and there was a statistically significant difference in scores between these two groups (p=0.000). The Turkish version of the Singing Voice Handicap Index is a valid and reliable scale which can be used in the evaluation of voice problems of Turkish-speaking singing voice users.

  7. High-Performance, Reliable Multicasting: Foundations for Future Internet Groupware Applications

    NASA Technical Reports Server (NTRS)

    Callahan, John; Montgomery, Todd; Whetten, Brian

    1997-01-01

    Network protocols that provide efficient, reliable, and totally-ordered message delivery to large numbers of users will be needed to support many future Internet applications. The Reliable Multicast Protocol (RMP) is implemented on top of IP multicast to facilitate reliable transfer of data for replicated databases and groupware applications that will emerge on the Internet over the next decade. This paper explores some of the basic questions and applications of reliable multicasting in the context of the development and analysis of RMP.

  8. 76 FR 42534 - Mandatory Reliability Standards for Interconnection Reliability Operating Limits; System...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-19

    ... Reliability Operating Limits; System Restoration Reliability Standards AGENCY: Federal Energy Regulatory... data necessary to analyze and monitor Interconnection Reliability Operating Limits (IROL) within its... Interconnection Reliability Operating Limits, Order No. 748, 134 FERC ] 61,213 (2011). \\2\\ The term ``Wide-Area...

  9. Reliability testing of two classification systems for osteoarthritis and post-traumatic arthritis of the elbow.

    PubMed

    Amini, Michael H; Sykes, Joshua B; Olson, Stephen T; Smith, Richard A; Mauck, Benjamin M; Azar, Frederick M; Throckmorton, Thomas W

    2015-03-01

    The severity of elbow arthritis is one of many factors that surgeons must evaluate when considering treatment options for a given patient. Elbow surgeons have historically used the Broberg and Morrey (BM) and Hastings and Rettig (HR) classification systems to radiographically stage the severity of post-traumatic arthritis (PTA) and primary osteoarthritis (OA). We proposed to compare the intraobserver and interobserver reliability between systems for patients with either PTA or OA. The radiographs of 45 patients were evaluated at least 2 weeks apart by 6 evaluators of different levels of training. Intraobserver and interobserver reliability were calculated by Spearman correlation coefficients with 95% confidence intervals. Agreement was considered almost perfect for coefficients >0.80 and substantial for coefficients of 0.61 to 0.80. In patients with both PTA and OA, intraobserver reliability and interobserver reliability were substantial, with no difference between classification systems. There were no significant differences in intraobserver or interobserver reliability between attending physicians and trainees for either classification system (all P > .10). The presence of fracture implants did not affect reliability in the BM system but did substantially worsen reliability in the HR system (intraobserver P = .04 and interobserver P = .001). The BM and HR classifications both showed substantial intraobserver and interobserver reliability for PTA and OA. Training level differences did not affect reliability for either system. Both trainees and fellowship-trained surgeons may easily and reliably apply each classification system to the evaluation of primary elbow OA and PTA, although the HR system was less reliable in the presence of fracture implants. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  10. Reliable actuators for twin rotor MIMO system

    NASA Astrophysics Data System (ADS)

    Rao, Vidya S.; V. I, George; Kamath, Surekha; Shreesha, C.

    2017-11-01

    Twin Rotor MIMO System (TRMS) is a bench mark system to test flight control algorithms. One of the perturbations on TRMS which is likely to affect the control system is actuator failure. Therefore, there is a need for a reliable control system, which includes H infinity controller along with redundant actuators. Reliable control refers to the design of a control system to tolerate failures of a certain set of actuators or sensors while retaining desired control system properties. Output of reliable controller has to be transferred to the redundant actuator effectively to make the TRMS reliable even under actual actuator failure.

  11. A reliable, compact, and repetitive-rate high power microwave generation system.

    PubMed

    Li, Wei; Li, Zhi-qiang; Sun, Xiao-liang; Zhang, Jun

    2015-11-01

    A compact high power microwave (HPM) generation system is described in this paper. The main parts of the HPM system are a Marx generator with a pulse forming line and a magnetron with diffraction output. The total weight and length of the system are 250 kg and 120 cm, respectively. The output microwave power of the HPM system at 550 kV of applied voltage and 0.33 T of magnetic field reaches 1 GW at 2.32 GHz of central frequency with 38 ns of pulse duration, 23% of power conversion efficiency, and Gaussian radiation pattern. In the bursts operation, both time and amplitude jitters are less than 4 ns and lower than 1.5 dB, respectively.

  12. A reliable, compact, and repetitive-rate high power microwave generation system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Wei; Li, Zhi-qiang; Sun, Xiao-liang

    2015-11-15

    A compact high power microwave (HPM) generation system is described in this paper. The main parts of the HPM system are a Marx generator with a pulse forming line and a magnetron with diffraction output. The total weight and length of the system are 250 kg and 120 cm, respectively. The output microwave power of the HPM system at 550 kV of applied voltage and 0.33 T of magnetic field reaches 1 GW at 2.32 GHz of central frequency with 38 ns of pulse duration, 23% of power conversion efficiency, and Gaussian radiation pattern. In the bursts operation, both timemore » and amplitude jitters are less than 4 ns and lower than 1.5 dB, respectively.« less

  13. Test-retest reliability at the item level and total score level of the Norwegian version of the Spinal Cord Injury Falls Concern Scale (SCI-FCS).

    PubMed

    Roaldsen, Kirsti Skavberg; Måøy, Åsa Blad; Jørgensen, Vivien; Stanghelle, Johan Kvalvik

    2016-05-01

    Translation of the Spinal Cord Injury Falls Concern Scale (SCI-FCS), and investigation of test-retest reliability on item-level and total-score-level. Translation, adaptation and test-retest study. A specialized rehabilitation setting in Norway. Fifty-four wheelchair users with a spinal cord injury. The median age of the cohort was 49 years, and the median number of years after injury was 13. Interventions/measurements: The SCI-FCS was translated and back-translated according to guidelines. Individuals answered the SCI-FCS twice over the course of one week. We investigated item-level test-retest reliability using Svensson's rank-based statistical method for disagreement analysis of paired ordinal data. For relative reliability, we analyzed the total-score-level test-retest reliability with intraclass correlation coefficients (ICC2.1), the standard error of measurement (SEM), and the smallest detectable change (SDC) for absolute reliability/measurement-error assessment and Cronbach's alpha for internal consistency. All items showed satisfactory percentage agreement (≥69%) between test and retest. There were small but non-negligible systematic disagreements among three items; we recovered an 11-13% higher chance for a lower second score. There was no disagreement due to random variance. The test-retest agreement (ICC2.1) was excellent (0.83). The SEM was 2.6 (12%), and the SDC was 7.1 (32%). The Cronbach's alpha was high (0.88). The Norwegian SCI-FCS is highly reliable for wheelchair users with chronic spinal cord injuries.

  14. Parts and Components Reliability Assessment: A Cost Effective Approach

    NASA Technical Reports Server (NTRS)

    Lee, Lydia

    2009-01-01

    System reliability assessment is a methodology which incorporates reliability analyses performed at parts and components level such as Reliability Prediction, Failure Modes and Effects Analysis (FMEA) and Fault Tree Analysis (FTA) to assess risks, perform design tradeoffs, and therefore, to ensure effective productivity and/or mission success. The system reliability is used to optimize the product design to accommodate today?s mandated budget, manpower, and schedule constraints. Stand ard based reliability assessment is an effective approach consisting of reliability predictions together with other reliability analyses for electronic, electrical, and electro-mechanical (EEE) complex parts and components of large systems based on failure rate estimates published by the United States (U.S.) military or commercial standards and handbooks. Many of these standards are globally accepted and recognized. The reliability assessment is especially useful during the initial stages when the system design is still in the development and hard failure data is not yet available or manufacturers are not contractually obliged by their customers to publish the reliability estimates/predictions for their parts and components. This paper presents a methodology to assess system reliability using parts and components reliability estimates to ensure effective productivity and/or mission success in an efficient manner, low cost, and tight schedule.

  15. Theory of reliable systems. [systems analysis and design

    NASA Technical Reports Server (NTRS)

    Meyer, J. F.

    1973-01-01

    The analysis and design of reliable systems are discussed. The attributes of system reliability studied are fault tolerance, diagnosability, and reconfigurability. Objectives of the study include: to determine properties of system structure that are conducive to a particular attribute; to determine methods for obtaining reliable realizations of a given system; and to determine how properties of system behavior relate to the complexity of fault tolerant realizations. A list of 34 references is included.

  16. Low Temperature Testing of a Radiation Hardened CMOS 8-Bit Flash Analog-to-Digital (A/D) Converter

    NASA Technical Reports Server (NTRS)

    Gerber, Scott S.; Hammond, Ahmad; Elbuluk, Malik E.; Patterson, Richard L.; Overton, Eric; Ghaffarian, Reza; Ramesham, Rajeshuni; Agarwal, Shri G.

    2001-01-01

    Power processing electronic systems, data acquiring probes, and signal conditioning circuits are required to operate reliably under harsh environments in many of NASA:s missions. The environment of the space mission as well as the operational requirements of some of the electronic systems, such as infrared-based satellite or telescopic observation stations where cryogenics are involved, dictate the utilization of electronics that can operate efficiently and reliably at low temperatures. In this work, radiation-hard CMOS 8-bit flash A/D converters were characterized in terms of voltage conversion and offset in the temperature range of +25 to -190 C. Static and dynamic supply currents, ladder resistance, and gain and offset errors were also obtained in the temperature range of +125 to -190 C. The effect of thermal cycling on these properties for a total of ten cycles between +80 and - 150 C was also determined. The experimental procedure along with the data obtained are reported and discussed in this paper.

  17. Electrochemical disinfection of repeatedly recycled blackwater in a free‐standing, additive‐free toilet

    PubMed Central

    Sellgren, Katelyn L.; Klem, Ethan J. D.; Piascik, Jeffrey R.; Stoner, Brian R.

    2017-01-01

    Abstract Decentralized, energy‐efficient waste water treatment technologies enabling water reuse are needed to sustainably address sanitation needs in water‐ and energy‐scarce environments. Here, we describe the effects of repeated recycling of disinfected blackwater (as flush liquid) on the energy required to achieve full disinfection with an electrochemical process in a prototype toilet system. The recycled liquid rapidly reached a steady state with total solids reliably ranging between 0.50 and 0.65% and conductivity between 20 and 23 mS/cm through many flush cycles over 15 weeks. The increase in accumulated solids was associated with increased energy demand and wide variation in the free chlorine contact time required to achieve complete disinfection. Further studies on the system at steady state revealed that running at higher voltage modestly improves energy efficiency, and established running parameters that reliably achieve disinfection at fixed run times. These results will guide prototype testing in the field. PMID:29242713

  18. Study on the Validity and Reliability of Melbourne Decision Making Scale in Turkey

    ERIC Educational Resources Information Center

    Çolakkadioglu, Oguzhan; Deniz, M. Engin

    2015-01-01

    This study is to analyze the validity and reliability of Melbourne Decision Making Questionnaire (MDMQ). The sample consisted of 650 university students. The structural validity of the MDMQ, as well as correlations among its sub-scales, measure-bound validity, internal consistency, item total correlations and test-retest reliability coefficients…

  19. Reliability of a Longitudinal Sequence of Scale Ratings

    ERIC Educational Resources Information Center

    Laenen, Annouschka; Alonso, Ariel; Molenberghs, Geert; Vangeneugden, Tony

    2009-01-01

    Reliability captures the influence of error on a measurement and, in the classical setting, is defined as one minus the ratio of the error variance to the total variance. Laenen, Alonso, and Molenberghs ("Psychometrika" 73:443-448, 2007) proposed an axiomatic definition of reliability and introduced the R[subscript T] coefficient, a measure of…

  20. 76 FR 64082 - Mandatory Reliability Standards for the Bulk-Power System; Notice of Staff Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-17

    ... Reliability Standards for the Bulk-Power System; Notice of Staff Meeting Take notice that the Federal Energy... reliability implications to the interconnected transmission system associated with a single point of failure... R1.3.10 of Commission-approved transmission planning Reliability Standard TPL-002- 0 (System...

  1. [Reliability and validity of Driving Anger Scale in professional drivers in China].

    PubMed

    Li, Z; Yang, Y M; Zhang, C; Li, Y; Hu, J; Gao, L W; Zhou, Y X; Zhang, X J

    2017-11-10

    Objective: To assess the reliability and validity of the Chinese version of Driving Anger Scale (DAS) in professional drivers in China and provide a scientific basis for the application of the scale in drivers in China. Methods: Professional drivers, including taxi drivers, bus drivers, truck drivers and school bus drivers, were selected to complete the questionnaire. Cronbach's α and split-half reliability were calculated to evaluate the reliability of DAS, and content, contract, discriminant and convergent validity were performed to measure the validity of the scale. Results: The overall Cronbach's α of DAS was 0.934 and the split-half reliability was 0.874. The correlation coefficient of each subscale with the total scale was 0.639-0.922. The simplified version of DAS supported a presupposed six-factor structure, explaining 56.371% of the total variance revealed by exploratory factor analysis. The DAS had good convergent and discriminant validity, with the success rate of calibration experiment of 100%. Conclusion: DAS has a good reliability and validity in professional drivers in China, and the use of DAS is worth promoting in divers.

  2. Reliability of primary caregivers reports on lifestyle behaviours of European pre-school children: the ToyBox-study.

    PubMed

    González-Gil, E M; Mouratidou, T; Cardon, G; Androutsos, O; De Bourdeaudhuij, I; Góźdź, M; Usheva, N; Birnbaum, J; Manios, Y; Moreno, L A

    2014-08-01

    Reliable assessments of health-related behaviours are necessary for accurate evaluation on the efficiency of public health interventions. The aim of the current study was to examine the reliability of a self-administered primary caregivers questionnaire (PCQ) used in the ToyBox-intervention. The questionnaire consisted of six sections addressing sociodemographic and perinatal factors, water and beverages consumption, physical activity, snacking and sedentary behaviours. Parents/caregivers from six countries (Belgium, Bulgaria, Germany, Greece, Poland and Spain) were asked to complete the questionnaire twice within a 2-week interval. A total of 93 questionnaires were collected. Test-retest reliability was assessed using intra-class correlation coefficient (ICC). Reliability of the six questionnaire sections was assessed. A stronger agreement was observed in the questions addressing sociodemographic and perinatal factors as opposed to questions addressing behaviours. Findings showed that 92% of the ToyBox PCQ had a moderate-to-excellent test-retest reliability (defined as ICC values from 0.41 to 1) and less than 8% poor test-retest reliability (ICC < 0.40). Out of the total ICC values, 67% showed good-to-excellent reliability (ICC from 0.61 to 1). We conclude that the PCQ is a reliable tool to assess sociodemographic characteristics, perinatal factors and lifestyle behaviours of pre-school children and their families participating in the ToyBox-intervention. © 2014 World Obesity.

  3. Development and Evaluation of a Questionnaire for Measuring Suboptimal Health Status in Urban Chinese

    PubMed Central

    Yan, Yu-Xiang; Liu, You-Qin; Li, Man; Hu, Pei-Feng; Guo, Ai-Min; Yang, Xing-Hua; Qiu, Jing-Jun; Yang, Shan-Shan; Shen, Jian; Zhang, Li-Ping; Wang, Wei

    2009-01-01

    Background Suboptimal health status (SHS) is characterized by ambiguous health complaints, general weakness, and lack of vitality, and has become a new public health challenge in China. It is believed to be a subclinical, reversible stage of chronic disease. Studies of intervention and prognosis for SHS are expected to become increasingly important. Consequently, a reliable and valid instrument to assess SHS is essential. We developed and evaluated a questionnaire for measuring SHS in urban Chinese. Methods Focus group discussions and a literature review provided the basis for the development of the questionnaire. Questionnaire validity and reliability were evaluated in a small pilot study and in a larger cross-sectional study of 3000 individuals. Analyses included tests for reliability and internal consistency, exploratory and confirmatory factor analysis, and tests for discriminative ability and convergent validity. Results The final questionnaire included 25 items on SHS (SHSQ-25), and encompassed 5 subscales: fatigue, the cardiovascular system, the digestive tract, the immune system, and mental status. Overall, 2799 of 3000 participants completed the questionnaire (93.3%). Test-retest reliability coefficients of individual items ranged from 0.89 to 0.98. Item-subscale correlations ranged from 0.51 to 0.72, and Cronbach’s α was 0.70 or higher for all subscales. Factor analysis established 5 distinct domains, as conceptualized in our model. One-way ANOVA showed statistically significant differences in scale scores between 3 occupation groups; these included total scores and subscores (P < 0.01). The correlation between the SHS scores and experienced stress was statistically significant (r = 0.57, P < 0.001). Conclusions The SHSQ-25 is a reliable and valid instrument for measuring sub-health status in urban Chinese. PMID:19749497

  4. Incident learning in pursuit of high reliability: implementing a comprehensive, low-threshold reporting program in a large, multisite radiation oncology department.

    PubMed

    Gabriel, Peter E; Volz, Edna; Bergendahl, Howard W; Burke, Sean V; Solberg, Timothy D; Maity, Amit; Hahn, Stephen M

    2015-04-01

    Incident learning programs have been recognized as cornerstones of safety and quality assurance in so-called high reliability organizations in industries such as aviation and nuclear power. High reliability organizations are distinguished by their drive to continuously identify and proactively address a broad spectrum of latent safety issues. Many radiation oncology institutions have reported on their experience in tracking and analyzing adverse events and near misses but few have incorporated the principles of high reliability into their programs. Most programs have focused on the reporting and retrospective analysis of a relatively small number of significant adverse events and near misses. To advance a large, multisite radiation oncology department toward high reliability, a comprehensive, cost-effective, electronic condition reporting program was launched to enable the identification of a broad spectrum of latent system failures, which would then be addressed through a continuous quality improvement process. A comprehensive program, including policies, work flows, and information system, was designed and implemented, with use of a low reporting threshold to focus on precursors to adverse events. In a 46-month period from March 2011 through December 2014, a total of 8,504 conditions (average, 185 per month, 1 per patient treated, 3.9 per 100 fractions [individual treatments]) were reported. Some 77.9% of clinical staff members reported at least 1 condition. Ninety-eight percent of conditions were classified in the lowest two of four severity levels, providing the opportunity to address conditions before they contribute to adverse events. Results after approximately four years show excellent employee engagement, a sustained rate of reporting, and a focus on low-level issues leading to proactive quality improvement interventions.

  5. Reliability and validity of the delta finger-to-palm (FTP), a new measure of finger range of motion in systemic sclerosis

    PubMed Central

    Torok, Kathryn S.; Baker, Nancy A.; Lucas, Mary; Domsic, Robyn T.; Boudreau, Robert; Medsger, Thomas A.

    2010-01-01

    Objectives To determine the reliability and validity of a new measure of finger motion in patients with systemic sclerosis (SSc), the ‘delta finger-to-palm’ (delta FTP) and compare its psychometric properties to the traditional measure of finger motion, the finger-to-palm (FTP). Methods Phase 1: The reliability of the delta FTP and FTP were examined in 39 patients with SSc. Phase 2: Criterion and convergent construct validity of both measures were examined in 17 patients with SSc by comparing them to other clinical measures: Total Active Range of Motion (TAROM), Hand Mobility in Scleroderma (HAMIS), the Duruoz Hand Index (DHI), Health Assessment Questionnaire (HAQ), and modified Rodnan skin score (mRSS). Phase 3: Sensitivity to change of the delta FTP was investigated in 24 patients with early diffuse cutaneous SSc. Results Both measures had excellent intra-rater and inter-rater reliability (ICC 0.92 to 0.99). Fair to strong correlations (rs=0.49–0.94) were observed between the delta FTP and TAROM, HAMIS, and DHI. Fair to moderate correlations were observed between delta FTP and HAQ components related to hand function and upper extremity mRSS. Correlations of the traditional FTP with these measures were fair to strong, but most often the delta FTP outperformed the FTP. The effect size and standardised response mean for the mean delta FTP were 0.50 and 1.10 respectively, over a 2–8 month period. Conclusion The delta FTP is a valid and reliable measure of finger motion in patients with SSc which outperforms the FTP. PMID:20576211

  6. Test-retest reliability of biodex system 4 pro for isometric ankle-eversion and -inversion measurement.

    PubMed

    Tankevicius, Gediminas; Lankaite, Doanata; Krisciunas, Aleksandras

    2013-08-01

    The lack of knowledge about isometric ankle testing indicates the need for research in this area. to assess test-retest reliability and to determine the optimal position for isometric ankle-eversion and -inversion testing. Test-retest reliability study. Isometric ankle eversion and inversion were assessed in 3 different dynamometer foot-plate positions: 0°, 7°, and 14° of inversion. Two maximal repetitions were performed at each angle. Both limbs were tested (40 ankles in total). The test was performed 2 times with a period of 7 d between the tests. University hospital. The study was carried out on 20 healthy athletes with no history of ankle sprains. Reliability was assessed using intraclass correlation coefficient (ICC2,1); minimal detectable change (MDC) was calculated using a 95% confidence interval. Paired t test was used to measure statistically significant changes, and P <.05 was considered statistically significant. Eversion and inversion peak torques showed high ICCs in all 3 angles (ICC values .87-.96, MDC values 3.09-6.81 Nm). Eversion peak torque was the smallest when testing at the 0° angle and gradually increased, reaching maximum values at 14° angle. The increase of eversion peak torque was statistically significant at 7 ° and 14° of inversion. Inversion peak torque showed an opposite pattern-it was the smallest when measured at the 14° angle and increased at the other 2 angles; statistically significant changes were seen only between measures taken at 0° and 14°. Isometric eversion and inversion testing using the Biodex 4 Pro system is a reliable method. The authors suggest that the angle of 7° of inversion is the best for isometric eversion and inversion testing.

  7. Space Transportation System Availability Relationships to Life Cycle Cost

    NASA Technical Reports Server (NTRS)

    Rhodes, Russel E.; Donahue, Benjamin B.; Chen, Timothy T.

    2009-01-01

    Future space transportation architectures and designs must be affordable. Consequently, their Life Cycle Cost (LCC) must be controlled. For the LCC to be controlled, it is necessary to identify all the requirements and elements of the architecture at the beginning of the concept phase. Controlling LCC requires the establishment of the major operational cost drivers. Two of these major cost drivers are reliability and maintainability, in other words, the system's availability (responsiveness). Potential reasons that may drive the inherent availability requirement are the need to control the number of unique parts and the spare parts required to support the transportation system's operation. For more typical space transportation systems used to place satellites in space, the productivity of the system will drive the launch cost. This system productivity is the resultant output of the system availability. Availability is equal to the mean uptime divided by the sum of the mean uptime plus the mean downtime. Since many operational factors cannot be projected early in the definition phase, the focus will be on inherent availability which is equal to the mean time between a failure (MTBF) divided by the MTBF plus the mean time to repair (MTTR) the system. The MTBF is a function of reliability or the expected frequency of failures. When the system experiences failures the result is added operational flow time, parts consumption, and increased labor with an impact to responsiveness resulting in increased LCC. The other function of availability is the MTTR, or maintainability. In other words, how accessible is the failed hardware that requires replacement and what operational functions are required before and after change-out to make the system operable. This paper will describe how the MTTR can be equated to additional labor, additional operational flow time, and additional structural access capability, all of which drive up the LCC. A methodology will be presented that provides the decision makers with the understanding necessary to place constraints on the design definition. This methodology for the major drivers will determine the inherent availability, safety, reliability, maintainability, and the life cycle cost of the fielded system. This methodology will focus on the achievement of an affordable, responsive space transportation system. It is the intent of this paper to not only provide the visibility of the relationships of these major attribute drivers (variables) to each other and the resultant system inherent availability, but also to provide the capability to bound the variables, thus providing the insight required to control the system's engineering solution. An example of this visibility is the need to provide integration of similar discipline functions to allow control of the total parts count of the space transportation system. Also, selecting a reliability requirement will place a constraint on parts count to achieve a given inherent availability requirement, or require accepting a larger parts count with the resulting higher individual part reliability requirements. This paper will provide an understanding of the relationship of mean repair time (mean downtime) to maintainability (accessibility for repair), and both mean time between failure (reliability of hardware) and the system inherent availability.

  8. [Water and suspended matter sampling in fresh water networks].

    PubMed

    Galas, Chiara; Stellato, Luisa; Barbizzi, Sabrina; Belli, Maria; Sansone, Umberto

    2005-01-01

    Metals and radionuclides in water systems can be easily adsorbed on suspended matter and, finally, they could eventually accumulate in the aquatic environment. The assessment of the health of a water body needs also sampling of the suspended matter fraction. In this paper sampling systems to characterise contaminants associated with the suspended matter fraction are described, with a particular attention to the collection and preservation of samples. Sampling must be representative, to obtain reliable conclusions. In this context it is stressed the importance of the evaluation of the sampling uncertainty, which contributes to a large extent to the total uncertainty.

  9. Modify Federal Tax Code to Create Incentives for Individuals to Obtain Coverage.

    PubMed

    McGlynn, Elizabeth A

    2011-01-01

    This article explores how a refundable tax credit to offset the cost of health insurance premiums would affect health system performance along nine dimensions. A refundable tax credit would produce a slight gain in health as measured by life expectancy; 2.3 to 10 million people would become newly insured under this policy change. It is uncertain how the policy would affect waste or patient experience. Refundable tax credits would have no discernable effect on total health care spending, overall consumer financial risk, reliability of care, or health system capacity. Implementing refundable tax credits would be relatively easy.

  10. Field Programmable Gate Array Failure Rate Estimation Guidelines for Launch Vehicle Fault Tree Models

    NASA Technical Reports Server (NTRS)

    Al Hassan, Mohammad; Britton, Paul; Hatfield, Glen Spencer; Novack, Steven D.

    2017-01-01

    Today's launch vehicles complex electronic and avionics systems heavily utilize Field Programmable Gate Array (FPGA) integrated circuits (IC) for their superb speed and reconfiguration capabilities. Consequently, FPGAs are prevalent ICs in communication protocols such as MILSTD- 1553B and in control signal commands such as in solenoid valve actuations. This paper will identify reliability concerns and high level guidelines to estimate FPGA total failure rates in a launch vehicle application. The paper will discuss hardware, hardware description language, and radiation induced failures. The hardware contribution of the approach accounts for physical failures of the IC. The hardware description language portion will discuss the high level FPGA programming languages and software/code reliability growth. The radiation portion will discuss FPGA susceptibility to space environment radiation.

  11. Reliability enhancement through optimal burn-in

    NASA Astrophysics Data System (ADS)

    Kuo, W.

    1984-06-01

    A numerical reliability and cost model is defined for production line burn-in tests of electronic components. The necessity of burn-in is governed by upper and lower bounds: burn-in is mandatory for operation-critical or nonreparable component; no burn-in is needed when failure effects are insignificant or easily repairable. The model considers electronic systems in terms of a series of components connected by a single black box. The infant mortality rate is described with a Weibull distribution. Performance reaches a steady state after burn-in, and the cost of burn-in is a linear function for each component. A minimum cost is calculated among the costs and total time of burn-in, shop repair, and field repair, with attention given to possible losses in future sales from inadequate burn-in testing.

  12. The Location of Anterior Cruciate Ligament Tears: A Prevalence Study Using Magnetic Resonance Imaging

    PubMed Central

    van der List, Jelle P.; Mintz, Douglas N.; DiFelice, Gregory S.

    2017-01-01

    Background: Over the past decade, there has been a resurgence of interest in anterior cruciate ligament (ACL) preservation. Proximal and distal avulsion tears have been treated with arthroscopic primary repair, while augmented repair, remnant tensioning, primary repair with biological scaffold, and remnant preservation have been proposed for different types of midsubstance tears. Currently, the incidence of these different tear types is unknown. Purpose: To propose a magnetic resonance imaging (MRI) classification system for different tear types based on clinical relevance and to assess the distribution of these different ACL tear types. Study Design: Case series; Level of evidence, 4. Methods: A retrospective search in an institutional radiographic database was performed for patients who underwent knee MRI at our institution between June 2014 and June 2016. Patients younger than 18 years and those with reports of chronic tears, partial tears, multiligamentous injuries, were excluded. Tear types were graded as proximal avulsion (distal remnant length >90% of total ligament length, type I), proximal (75%-90%, type II), midsubstance (25%-75%, type III), distal (10%-25%, type IV), and distal avulsion (<10%, type V). An orthopaedic surgeon, a radiologist, and a research fellow graded the tear type on 30 MRIs to determine reliability, and the research fellow graded all MRIs. Inter- and intraobserver reliability were measured using kappa statistics. Results: A total of 353 patients (57% male; mean age, 37.1 years; range, 18.1-81.2 years) were included. Interobserver reliability was 0.670 (95% confidence interval, 0.505-0.836), and intraobserver reliability ranged from 0.741 to 0.934. Incidence of type I tears was 16%, type II tears 27%, type III tears 52%, type IV tears 1%, and type V tears 3% (2.5% with bony avulsion). Type I tears were more common in patients older than 35 years compared with those younger than 35 years (23% vs 8%; P < .001). Conclusion: This classification system was reliable in assessing tear location in acute ACL injuries. Type I tears were seen in 16%, type II in 27%, and type III in 52% of patients in our cohort. These data suggest that there may be greater potential application for ACL preservation techniques. PMID:28680889

  13. Oxygen uptake during functional activities after stroke—Reliability and validity of a portable ergospirometry system

    PubMed Central

    Brurok, Berit; Tjønna, Arnt Erik; Tørhaug, Tom; Askim, Torunn

    2017-01-01

    Background People with stroke have a low peak aerobic capacity and experience increased effort during performance of daily activities. The purpose of this study was to examine test-retest reliability of a portable ergospirometry system in people with stroke during performance of functional activities in a field-test. Secondary aims were to examine the proportion of oxygen consumed during the field-test in relation to the peak-test and to analyse the correlation between the oxygen uptake during the field-test and peak-test in order to support the validity of the field-test. Methods With simultaneous measurement of oxygen consumption, participants performed a standardized field-test consisting of five activities; walking over ground, stair walking, stepping over obstacles, walking slalom between cones and from a standing position lifting objects from one height to another. All activities were performed in self-selected speed. Prior to the field-test, a peak aerobic capacity test was performed. The field-test was repeated minimum 2 and maximum 14 days between the tests. ICC2,1 and Bland Altman tests (Limits of Agreement, LoA) were used to analyse test-retest reliability. Results In total 31 participants (39% women, mean (SD) age 54.5 (12.7) years and 21.1 (14.3) months’ post-stroke) were included. The ICC2,1 was ≥ 0.80 for absolute V̇O2, relative V̇O2, minute ventilation, CO2, respiratory exchange ratio, heart rate and Borgs rating of perceived exertion. ICC2,1 for total time to complete the field-test was 0.99. Mean difference in steady state V̇O2 during Test 1 and Test 2 was -0.40 (2.12) The LoAs were -3.75 and 4.51. Participants spent 60.7% of their V̇O2peak performing functional activities. Correlation between field-test and peak-test was 0.689, p = 0.001 for absolute and 0.733, p = 0.001 for relative V̇O2. Conclusions This study presents first evidence on reliability of oxygen uptake during performance of functional activities after stroke, showing very good test-retest reliability. The secondary analysis showed that the amount of energy spent during the field-test relative to the peak-test was high and the correlation between the two test was good, supporting the validity of this method. PMID:29065164

  14. Rating scales for dystonia in cerebral palsy: reliability and validity.

    PubMed

    Monbaliu, E; Ortibus, E; Roelens, F; Desloovere, K; Deklerck, J; Prinzie, P; de Cock, P; Feys, H

    2010-06-01

    This study investigated the reliability and validity of the Barry-Albright Dystonia Scale (BADS), the Burke-Fahn-Marsden Movement Scale (BFMMS), and the Unified Dystonia Rating Scale (UDRS) in patients with bilateral dystonic cerebral palsy (CP). Three raters independently scored videotapes of 10 patients (five males, five females; mean age 13 y 3 mo, SD 5 y 2 mo, range 5-22 y). One patient each was classified at levels I-IV in the Gross Motor Function Classification System and six patients were classified at level V. Reliability was measured by (1) intraclass correlation coefficient (ICC) for interrater reliability, (2) standard error of measurement (SEM) and smallest detectable difference (SDD), and (3) Cronbach's alpha for internal consistency. Validity was assessed by Pearson's correlations among the three scales used and by content analysis. Moderate to good interrater reliability was found for total scores of the three scales (ICC: BADS=0.87; BFMMS=0.86; UDRS=0.79). However, many subitems showed low reliability, in particular for the UDRS. SEM and SDD were respectively 6.36% and 17.72% for the BADS, 9.88% and 27.39% for the BFMMS, and 8.89% and 24.63% for the UDRS. High internal consistency was found. Pearson's correlations were high. Content validity showed insufficient accordance with the new CP definition and classification. Our results support the internal consistency and concurrent validity of the scales; however, taking into consideration the limitations in reliability, including the large SDD values and the content validity, further research on methods of assessment of dystonia is warranted.

  15. [Analysis of reliability and validity of the Chinese Version of Dizziness Handicap Inventory (DHI)].

    PubMed

    Zhang, Yi; Liu, Bo; Wang, Yongjun; Zhou, Yun; Wang, Rui; Gong, Jing; Peng, Xiaoxia

    2015-09-01

    To investigate the reliability and validity of the Chinese Version of Dizziness Handicap Inventory (DHI). Cross-cultural adaptation of health-related quality of life measures was used for translating the DHI to Chinese version. The DHI contains 7 physical, 9 emotional, and 9 functional questions.The patients scored the DHI straightforward. Then the scores of the total scale and each subscales were calculated and evaluated.Three hundred and sixty-six dizzy patients,116 males and 250 females, aged from 14 to 79 years, were included in the research and finished the questionnaire of the evaluation.SPSS 13.0 was used for statistical analysis. Reliability: Cronbach α values for the total and subscale of DHI were 0.751-0.912. The reliability coefficients were 0.877-0.921 (P < 0.001). the correlation coefficients between the total scale and three subscale were 0.815-0.934 (P < 0.001). The correlation coefficients of the scores internal the subscale were higher than between the other subscale (r = 0.446-0.781). Common factor analysis provides 5 factors. The cumulative variance ratio was 54.5%. The component of each item was over 0.4. Chinese version of DHI has good reliability and validity, which can be used to evaluate the dizzy patients.

  16. [Turkish validity and reliability study of fear of pain questionnaire-III].

    PubMed

    Ünver, Seher; Turan, Fatma Nesrin

    2018-01-01

    This study aimed to develop a Turkish version of the Fear of Pain Questionnaire-III developed by McNeil and Rainwater (1998) and examine its validity and reliability indicators. The study was conducted with 459 university students studying in the nursing department. The Turkish translation of the scale was conducted by language experts and the original scale owner. Expert opinions were taken for language validity, and the Lawshe's content validity ratio formula was used to calculate the content validity. Exploratory factor analysis was used to assess the construct validity. The factors were rotated using the Varimax rotation (orthogonal) method. For reliability indicators of the questionnaire, the internal consistency coefficient and test re-test reliability were utilized. Explanatory factor analyses using the three-factor model (explaining 50.5% of the total variance) revealed that the item factor loads varied were above the limit value of 0.30 which indicated that the questionnaire had good construct validity. The Cronbach's alpha value for the total questionnaire was 0.938, and test re-test value was 0.846 for the total scale. The Turkish version of the Fear of Pain Questionnaire-III had sufficiently high reliability and validity to be used as a tool in evaluating the fear of pain among the young Turkish population.

  17. A study on reliability of power customer in distribution network

    NASA Astrophysics Data System (ADS)

    Liu, Liyuan; Ouyang, Sen; Chen, Danling; Ma, Shaohua; Wang, Xin

    2017-05-01

    The existing power supply reliability index system is oriented to power system without considering actual electricity availability in customer side. In addition, it is unable to reflect outage or customer’s equipment shutdown caused by instantaneous interruption and power quality problem. This paper thus makes a systematic study on reliability of power customer. By comparing with power supply reliability, reliability of power customer is defined and extracted its evaluation requirements. An indexes system, consisting of seven customer indexes and two contrast indexes, are designed to describe reliability of power customer from continuity and availability. In order to comprehensively and quantitatively evaluate reliability of power customer in distribution networks, reliability evaluation method is proposed based on improved entropy method and the punishment weighting principle. Practical application has proved that reliability index system and evaluation method for power customer is reasonable and effective.

  18. A Non-Contact Measurement System for the Range of Motion of the Hand

    PubMed Central

    Pham, Trieu; Pathirana, Pubudu N.; Trinh, Hieu; Fay, Pearse

    2015-01-01

    An accurate and standardised tool to measure the active range of motion (ROM) of the hand is essential to any progressive assessment scenario in hand therapy practice. Goniometers are widely used in clinical settings for measuring the ROM of the hand. However, such measurements have limitations with regard to inter-rater and intra-rater reliability and involve direct physical contact with the hand, possibly increasing the risk of transmitting infections. The system proposed in this paper is the first non-contact measurement system utilising Intel Perceptual Technology and a Senz3D Camera for measuring phalangeal joint angles. To enhance the accuracy of the system, we developed a new approach to achieve the total active movement without measuring three joint angles individually. An equation between the actual spacial position and measurement value of the proximal inter-phalangeal joint was established through the measurement values of the total active movement, so that its actual position can be inferred. Verified by computer simulations, experimental results demonstrated a significant improvement in the calculation of the total active movement and successfully recovered the actual position of the proximal inter-phalangeal joint angles. A trial that was conducted to examine the clinical applicability of the system involving 40 healthy subjects confirmed the practicability and consistency in the proposed system. The time efficiency conveyed a stronger argument for this system to replace the current practice of using goniometers. PMID:26225976

  19. Ultra Reliable Closed Loop Life Support for Long Space Missions

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.; Ewert, Michael K.

    2010-01-01

    Spacecraft human life support systems can achieve ultra reliability by providing sufficient spares to replace all failed components. The additional mass of spares for ultra reliability is approximately equal to the original system mass, provided that the original system reliability is not too low. Acceptable reliability can be achieved for the Space Shuttle and Space Station by preventive maintenance and by replacing failed units. However, on-demand maintenance and repair requires a logistics supply chain in place to provide the needed spares. In contrast, a Mars or other long space mission must take along all the needed spares, since resupply is not possible. Long missions must achieve ultra reliability, a very low failure rate per hour, since they will take years rather than weeks and cannot be cut short if a failure occurs. Also, distant missions have a much higher mass launch cost per kilogram than near-Earth missions. Achieving ultra reliable spacecraft life support systems with acceptable mass will require a well-planned and extensive development effort. Analysis must determine the reliability requirement and allocate it to subsystems and components. Ultra reliability requires reducing the intrinsic failure causes, providing spares to replace failed components and having "graceful" failure modes. Technologies, components, and materials must be selected and designed for high reliability. Long duration testing is needed to confirm very low failure rates. Systems design should segregate the failure causes in the smallest, most easily replaceable parts. The system must be designed, developed, integrated, and tested with system reliability in mind. Maintenance and reparability of failed units must not add to the probability of failure. The overall system must be tested sufficiently to identify any design errors. A program to develop ultra reliable space life support systems with acceptable mass should start soon since it must be a long term effort.

  20. Critical Assessment of the Foundations of Power Transmission and Distribution Reliability Metrics and Standards.

    PubMed

    Nateghi, Roshanak; Guikema, Seth D; Wu, Yue Grace; Bruss, C Bayan

    2016-01-01

    The U.S. federal government regulates the reliability of bulk power systems, while the reliability of power distribution systems is regulated at a state level. In this article, we review the history of regulating electric service reliability and study the existing reliability metrics, indices, and standards for power transmission and distribution networks. We assess the foundations of the reliability standards and metrics, discuss how they are applied to outages caused by large exogenous disturbances such as natural disasters, and investigate whether the standards adequately internalize the impacts of these events. Our reflections shed light on how existing standards conceptualize reliability, question the basis for treating large-scale hazard-induced outages differently from normal daily outages, and discuss whether this conceptualization maps well onto customer expectations. We show that the risk indices for transmission systems used in regulating power system reliability do not adequately capture the risks that transmission systems are prone to, particularly when it comes to low-probability high-impact events. We also point out several shortcomings associated with the way in which regulators require utilities to calculate and report distribution system reliability indices. We offer several recommendations for improving the conceptualization of reliability metrics and standards. We conclude that while the approaches taken in reliability standards have made considerable advances in enhancing the reliability of power systems and may be logical from a utility perspective during normal operation, existing standards do not provide a sufficient incentive structure for the utilities to adequately ensure high levels of reliability for end-users, particularly during large-scale events. © 2015 Society for Risk Analysis.

  1. HiRel: Hybrid Automated Reliability Predictor (HARP) integrated reliability tool system, (version 7.0). Volume 3: HARP Graphics Oriented (GO) input user's guide

    NASA Technical Reports Server (NTRS)

    Bavuso, Salvatore J.; Rothmann, Elizabeth; Mittal, Nitin; Koppen, Sandra Howell

    1994-01-01

    The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of highly reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed at the outset to be compatible with most computing platforms and operating systems, and some programs have been beta tested within the aerospace community for over 8 years. This document is a user's guide for the HiRel graphical preprocessor Graphics Oriented (GO) program. GO is a graphical user interface for the HARP engine that enables the drawing of reliability/availability models on a monitor. A mouse is used to select fault tree gates or Markov graphical symbols from a menu for drawing.

  2. Evaluation Applied to Reliability Analysis of Reconfigurable, Highly Reliable, Fault-Tolerant, Computing Systems for Avionics

    NASA Technical Reports Server (NTRS)

    Migneault, G. E.

    1979-01-01

    Emulation techniques are proposed as a solution to a difficulty arising in the analysis of the reliability of highly reliable computer systems for future commercial aircraft. The difficulty, viz., the lack of credible precision in reliability estimates obtained by analytical modeling techniques are established. The difficulty is shown to be an unavoidable consequence of: (1) a high reliability requirement so demanding as to make system evaluation by use testing infeasible, (2) a complex system design technique, fault tolerance, (3) system reliability dominated by errors due to flaws in the system definition, and (4) elaborate analytical modeling techniques whose precision outputs are quite sensitive to errors of approximation in their input data. The technique of emulation is described, indicating how its input is a simple description of the logical structure of a system and its output is the consequent behavior. The use of emulation techniques is discussed for pseudo-testing systems to evaluate bounds on the parameter values needed for the analytical techniques.

  3. Reliability design and verification for launch-vehicle propulsion systems - Report of an AIAA Workshop, Washington, DC, May 16, 17, 1989

    NASA Astrophysics Data System (ADS)

    Launch vehicle propulsion system reliability considerations during the design and verification processes are discussed. The tools available for predicting and minimizing anomalies or failure modes are described and objectives for validating advanced launch system propulsion reliability are listed. Methods for ensuring vehicle/propulsion system interface reliability are examined and improvements in the propulsion system development process are suggested to improve reliability in launch operations. Also, possible approaches to streamline the specification and procurement process are given. It is suggested that government and industry should define reliability program requirements and manage production and operations activities in a manner that provides control over reliability drivers. Also, it is recommended that sufficient funds should be invested in design, development, test, and evaluation processes to ensure that reliability is not inappropriately subordinated to other management considerations.

  4. Cross-cultural adaptation and validation of the Behcet’s Disease Current Activity Form in Korea

    PubMed Central

    Choi, Hyo Jin; Seo, Mi Ryoung; Ryu, Hee Jung; Baek, Han Joo

    2015-01-01

    Background/Aims: This study was undertaken to perform a cross-cultural adaptation of the Behcet’s Disease Current Activity Form (BDCAF, version 2006) questionnaire to the Korean language and to evaluate its reliability and validity in a population of Korean patients with Behcet’s disease (BD). Methods: A cross-cultural study was conducted among patients with BD who attended our rheumatology clinic between November 2012 and March 2013. There were 11 males and 35 females in the group. The mean age of the participants was 48.5 years and the mean disease duration was 6.4 years. The first BDCAF questionnaire was completed on arrival and the second assessment was performed 20 minutes later by a different physician. The test-retest reliability was analyzed by computing κ statistics. Kappa scores of > 0.6 indicated a good agreement. To assess the validity, we compared the total BDCAF score with the patient’s/clinician’s perception of disease activity and the Korean version of the Behcet’s Disease Quality of Life (BDQOL). Results: For the test-retest reliability, good agreements were achieved on items such as headache, oral/genital ulceration, erythema, skin pustules, arthralgia, nausea/vomiting/abdominal pain, and diarrhea with altered/frank blood per rectum. Moderate agreement was observed for eye and nervous system involvement. We achieved a fair agreement for arthritis and major vessel involvement. Significant correlations were obtained between the total BDCAF score with the BDQOL and the patient’s/clinician’s perception of disease activity p < 0.05). Conclusions: The Korean version of the BDCAF is a reliable and valid instrument for measuring current disease activity in Korean BD patients. PMID:26354066

  5. Reliability and Applicability of the Bayley Scale of Infant Development-II for Children With Cerebral Palsy.

    PubMed

    Lee, Ji Hyun; Lim, Hye Kyung; Park, Eunyoung; Song, Junyoung; Lee, Hee Song; Ko, Jooyeon; Kim, Minyoung

    2013-04-01

    To obtain reliability and applicability of the Korean version Bayley Scale of Infant Development-II (BSID-II) in evaluating the developmental status of children with cerebral palsy (CP). The inter-rater reliability of BSID-II scores from 68 children with CP (46 boys and 22 girls; mean age, 32.54±16.76 months; age range, 4 to 78 months) was evaluated by 10 pediatric occupational therapists. Patients were classified in several ways according to age group, typology, and the severity of motor impairment by the level of the Gross Motor Function Classification System (GMFCS). The measures were performed by video analysis, and the results of intraclass correlation (ICC) were obtained for each of the above classifications. To evaluate the clinical applicability of BSID-II for CP, its correlation with the Gross Motor Function Measure (GMFM), which has been known as the standard motor assessment for CP, was investigated. ICC was 0.99 for the Mental scale and 0.98 for the Motor scale in all subjects. The values of ICC ranged from 0.92 to 0.99 for each age group, 0.93 to 0.99 for each typology, and 0.99 to 1.00 for each GMFCS level. A strong positive correlation was found between the BSID-II Motor raw score and the GMFM total score (r=0.84, p<0.001), and a moderate correlation was observed between the BSID-II Mental raw score and the GMFM total score (r=0.65, p<0.001). The Korean version of BSID-II is a reliable tool to measure the functional status of children with CP. The raw scores of BSID-II showed a great correlation with GMFM, indicating validity of this measure for children with CP on clinical basis.

  6. Sliding mode based fault detection, reconstruction and fault tolerant control scheme for motor systems.

    PubMed

    Mekki, Hemza; Benzineb, Omar; Boukhetala, Djamel; Tadjine, Mohamed; Benbouzid, Mohamed

    2015-07-01

    The fault-tolerant control problem belongs to the domain of complex control systems in which inter-control-disciplinary information and expertise are required. This paper proposes an improved faults detection, reconstruction and fault-tolerant control (FTC) scheme for motor systems (MS) with typical faults. For this purpose, a sliding mode controller (SMC) with an integral sliding surface is adopted. This controller can make the output of system to track the desired position reference signal in finite-time and obtain a better dynamic response and anti-disturbance performance. But this controller cannot deal directly with total system failures. However an appropriate combination of the adopted SMC and sliding mode observer (SMO), later it is designed to on-line detect and reconstruct the faults and also to give a sensorless control strategy which can achieve tolerance to a wide class of total additive failures. The closed-loop stability is proved, using the Lyapunov stability theory. Simulation results in healthy and faulty conditions confirm the reliability of the suggested framework. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  7. Reliability and Validity of the Japanese Version of the Kinesthetic and Visual Imagery Questionnaire (KVIQ)

    PubMed Central

    Nakano, Hideki; Kodama, Takayuki; Ukai, Kazumasa; Kawahara, Satoru; Horikawa, Shiori; Murata, Shin

    2018-01-01

    In this study, we aimed to (1) translate the English version of the Kinesthetic and Visual Imagery Questionnaire (KVIQ), which assesses motor imagery ability, into Japanese, and (2) investigate the reliability and validity of the Japanese KVIQ. We enrolled 28 healthy adults in this study. We used Cronbach’s alpha coefficients to assess reliability reflected by the internal consistency. Additionally, we assessed validity reflected by the criterion-related validity between the Japanese KVIQ and the Japanese version of the Movement Imagery Questionnaire-Revised (MIQ-R) with Spearman’s rank correlation coefficients. The Cronbach’s alpha coefficients for the KVIQ-20 were 0.88 (Visual) and 0.91 (Kinesthetic), which indicates high reliability. There was a significant positive correlation between the Japanese KVIQ-20 (Total) and the Japanese MIQ-R (Total) (r = 0.86, p < 0.01). Our results suggest that the Japanese KVIQ is an assessment that is a reliable and valid index of motor imagery ability. PMID:29724042

  8. Reliability and Validity of the Japanese Version of the Kinesthetic and Visual Imagery Questionnaire (KVIQ).

    PubMed

    Nakano, Hideki; Kodama, Takayuki; Ukai, Kazumasa; Kawahara, Satoru; Horikawa, Shiori; Murata, Shin

    2018-05-02

    In this study, we aimed to (1) translate the English version of the Kinesthetic and Visual Imagery Questionnaire (KVIQ), which assesses motor imagery ability, into Japanese, and (2) investigate the reliability and validity of the Japanese KVIQ. We enrolled 28 healthy adults in this study. We used Cronbach’s alpha coefficients to assess reliability reflected by the internal consistency. Additionally, we assessed validity reflected by the criterion-related validity between the Japanese KVIQ and the Japanese version of the Movement Imagery Questionnaire-Revised (MIQ-R) with Spearman’s rank correlation coefficients. The Cronbach’s alpha coefficients for the KVIQ-20 were 0.88 (Visual) and 0.91 (Kinesthetic), which indicates high reliability. There was a significant positive correlation between the Japanese KVIQ-20 (Total) and the Japanese MIQ-R (Total) (r = 0.86, p < 0.01). Our results suggest that the Japanese KVIQ is an assessment that is a reliable and valid index of motor imagery ability.

  9. Application of the Modified Erikson Psychosocial Stage Inventory: 25 Years in Review.

    PubMed

    Darling-Fisher, Cynthia S

    2018-04-01

    The Modified Erikson Psychosocial Stage Inventory (MEPSI) is an 80-item, comprehensive measure of psychosocial development based on Erikson's theory with published reliability and validity data. Although designed as a comprehensive measure, some researchers have used individual subscales for specific developmental stages as a measure; however, these subscale reliability scores have not been generally shared. This article reviewed the literature to evaluate the use of the MEPSI: the major research questions, samples/populations studied, and individual subscale and total reliability and validity data. In total, 16 research articles (1990-2011) and 28 Dissertations/Theses (1991-2016) from nursing, social work, psychology, criminal justice, and religious studies met criteria. Results support the MEPSI's global reliability (aggregate scores ranged .89-.99) and validity in terms of consistent patterns of changes observed in the predicted direction. Reliability and validity data for individual subscales were more variable. Limitations of the tool and recommendations for possible revision and future research are addressed.

  10. [Translation and Development of the Chinese-Version Patient Privacy Scale].

    PubMed

    Chen, Li; Feng, Xian-Qiong; Yang, Xiao-Li; Li, Luo-Hong

    2017-06-01

    The unauthorized releasing of confidential patient information is a serious problem worldwide. Nurses, the healthcare professionals who are in most frequent contact with patients, have access to a significant amount of confidential patient information and play a key role in protecting patient privacy. However, currently, there is no proper tool to measure the level to which clinical nurses protect the privacy of their patients in China. To translate the patient privacy scale (PPS) into Chinese and to test the reliability and validity of this Chinese version. The original scale was developed by Özturk, Bahcecik, and Özçelik (2014) to identify whether nurses protect or violate patient privacy in the workplace. This study used the "back translation" method to translate the scale. A total of 616 nurses in two tertiary hospitals in the Western region of China were enrolled to test the internal consistency, test-retest reliability, and construct validity of the translated scale. The Cronbach's coefficients of the total scale and its 5 factors ranged from .84 to .94; the split half reliability was .91; the test-retest reliability was .82; and the content validity index was .95. Explanatory factor analysis revealed that the 5 factors explained 64.98% of the total variance. The Chinese version of the PPS is reliable and valid, and may be used to reliably assess the behaviors of nurses with regard to protecting the privacy of their patients. The scale may also be used to evaluate the effects of training on patient privacy protection.

  11. Minimum Control Requirements for Advanced Life Support Systems

    NASA Technical Reports Server (NTRS)

    Boulange, Richard; Jones, Harry; Jones, Harry

    2002-01-01

    Advanced control technologies are not necessary for the safe, reliable and continuous operation of Advanced Life Support (ALS) systems. ALS systems can and are adequately controlled by simple, reliable, low-level methodologies and algorithms. The automation provided by advanced control technologies is claimed to decrease system mass and necessary crew time by reducing buffer size and minimizing crew involvement. In truth, these approaches increase control system complexity without clearly demonstrating an increase in reliability across the ALS system. Unless these systems are as reliable as the hardware they control, there is no savings to be had. A baseline ALS system is presented with the minimal control system required for its continuous safe reliable operation. This baseline control system uses simple algorithms and scheduling methodologies and relies on human intervention only in the event of failure of the redundant backup equipment. This ALS system architecture is designed for reliable operation, with minimal components and minimal control system complexity. The fundamental design precept followed is "If it isn't there, it can't fail".

  12. Development of a Computer-Based Air Force Installation Restoration Workstation for Contaminant Modeling and Decision-Making

    DTIC Science & Technology

    1995-03-01

    advisory system provides a decision framework for selecting an appropriate model from the nuimerous available transport models conditinni-ed on...l1, T ,TV Groundwater Modeling, Contaminant Transport , Optimi2atio’ 2; Total Reliability, Remediation Si , , -J % UNCLASSIFIED UNCLASSIFIED...0 0 0 0 S 0 Sn S Even with the choice of an appropriate transport model, considlrable uncertainty is likely to be present in the analysis of

  13. Study on evaluation of construction reliability for engineering project based on fuzzy language operator

    NASA Astrophysics Data System (ADS)

    Shi, Yu-Fang; Ma, Yi-Yi; Song, Ping-Ping

    2018-03-01

    System Reliability Theory is a research hotspot of management science and system engineering in recent years, and construction reliability is useful for quantitative evaluation of project management level. According to reliability theory and target system of engineering project management, the defination of construction reliability appears. Based on fuzzy mathematics theory and language operator, value space of construction reliability is divided into seven fuzzy subsets and correspondingly, seven membership function and fuzzy evaluation intervals are got with the operation of language operator, which provides the basis of corresponding method and parameter for the evaluation of construction reliability. This method is proved to be scientific and reasonable for construction condition and an useful attempt for theory and method research of engineering project system reliability.

  14. Reliability models applicable to space telescope solar array assembly system

    NASA Technical Reports Server (NTRS)

    Patil, S. A.

    1986-01-01

    A complex system may consist of a number of subsystems with several components in series, parallel, or combination of both series and parallel. In order to predict how well the system will perform, it is necessary to know the reliabilities of the subsystems and the reliability of the whole system. The objective of the present study is to develop mathematical models of the reliability which are applicable to complex systems. The models are determined by assuming k failures out of n components in a subsystem. By taking k = 1 and k = n, these models reduce to parallel and series models; hence, the models can be specialized to parallel, series combination systems. The models are developed by assuming the failure rates of the components as functions of time and as such, can be applied to processes with or without aging effects. The reliability models are further specialized to Space Telescope Solar Arrray (STSA) System. The STSA consists of 20 identical solar panel assemblies (SPA's). The reliabilities of the SPA's are determined by the reliabilities of solar cell strings, interconnects, and diodes. The estimates of the reliability of the system for one to five years are calculated by using the reliability estimates of solar cells and interconnects given n ESA documents. Aging effects in relation to breaks in interconnects are discussed.

  15. Reliability of frames of reference used for tibial component rotation in total knee arthroplasty.

    PubMed

    Page, Stephen R; Deakin, Angela H; Payne, Anthony P; Picard, Frederic

    2011-01-01

    This study evaluated seven different frames of reference used for tibial component rotation in total knee arthroplasty (TKA) to determine which ones showed good reliability between bone specimens. An optoelectronic system based around a computer-assisted surgical navigation system was used to measure and locate 34 individual anatomical landmarks on 40 tibias. Each particular frame of reference was reconstructed from a group of data points taken from the surface of each bone. The transverse axis was used as the baseline to which the other axes were compared, and the differences in angular rotation between the other six reference frames and the transverse axis were calculated. There was high variability in the tibial rotational alignment associated with all frames of reference. Of the references widely used in current TKA procedures, the tibial tuberosity axis and the anterior condylar axis had lower standard deviations (6.1° and 7.3°, respectively) than the transmalleolar axis and the posterior condylar axis (9.3° for both). In conclusion, we found high variability in the frames of reference used for tibial rotation alignment. However, the anterior condylar axis and transverse axis may warrant further tests with the use of navigation. Combining different frames of reference such as the tibial tuberosity axis, anterior condylar axis and transverse axis may reduce the range of errors found in all of these measurements.

  16. High-throughput analysis using non-depletive SPME: challenges and applications to the determination of free and total concentrations in small sample volumes.

    PubMed

    Boyacı, Ezel; Bojko, Barbara; Reyes-Garcés, Nathaly; Poole, Justen J; Gómez-Ríos, Germán Augusto; Teixeira, Alexandre; Nicol, Beate; Pawliszyn, Janusz

    2018-01-18

    In vitro high-throughput non-depletive quantitation of chemicals in biofluids is of growing interest in many areas. Some of the challenges facing researchers include the limited volume of biofluids, rapid and high-throughput sampling requirements, and the lack of reliable methods. Coupled to the above, growing interest in the monitoring of kinetics and dynamics of miniaturized biosystems has spurred the demand for development of novel and revolutionary methodologies for analysis of biofluids. The applicability of solid-phase microextraction (SPME) is investigated as a potential technology to fulfill the aforementioned requirements. As analytes with sufficient diversity in their physicochemical features, nicotine, N,N-Diethyl-meta-toluamide, and diclofenac were selected as test compounds for the study. The objective was to develop methodologies that would allow repeated non-depletive sampling from 96-well plates, using 100 µL of sample. Initially, thin film-SPME was investigated. Results revealed substantial depletion and consequent disruption in the system. Therefore, new ultra-thin coated fibers were developed. The applicability of this device to the described sampling scenario was tested by determining the protein binding of the analytes. Results showed good agreement with rapid equilibrium dialysis. The presented method allows high-throughput analysis using small volumes, enabling fast reliable free and total concentration determinations without disruption of system equilibrium.

  17. Reliability of automatic biometric iris recognition after phacoemulsification or drug-induced pupil dilation.

    PubMed

    Seyeddain, Orang; Kraker, Hannes; Redlberger, Andreas; Dexl, Alois K; Grabner, Günther; Emesz, Martin

    2014-01-01

    To investigate the reliability of a biometric iris recognition system for personal authentication after cataract surgery or iatrogenic pupil dilation. This was a prospective, nonrandomized, single-center, cohort study for evaluating the performance of an iris recognition system 2-24 hours after phacoemulsification and intraocular lens implantation (group 1) and before and after iatrogenic pupil dilation (group 2). Of the 173 eyes that could be enrolled before cataract surgery, 164 (94.8%) were easily recognized postoperatively, whereas in 9 (5.2%) this was not possible. However, these 9 eyes could be reenrolled and afterwards recognized successfully. In group 2, of a total of 184 eyes that were enrolled in miosis, a total of 22 (11.9%) could not be recognized in mydriasis and therefore needed reenrollment. No single case of false-positive acceptance occurred in either group. The results of this trial indicate that standard cataract surgery seems not to be a limiting factor for iris recognition in the large majority of cases. Some patients (5.2% in this study) might need "reenrollment" after cataract surgery. Iris recognition was primarily successful in eyes with medically dilated pupils in nearly 9 out of 10 eyes. No single case of false-positive acceptance occurred in either group in this trial. It seems therefore that iris recognition is a valid biometric method in the majority of cases after cataract surgery or after pupil dilation.

  18. 78 FR 73112 - Monitoring System Conditions-Transmission Operations Reliability Standards; Interconnection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-05

    ..., RM13-14-000 and RM13-15-000] Monitoring System Conditions--Transmission Operations Reliability...) 502-6817, [email protected] . Robert T. Stroh (Legal Information), Office of the General... Reliability Standards ``address the important reliability goal of ensuring that the transmission system is...

  19. How reliable are clinical systems in the UK NHS? A study of seven NHS organisations

    PubMed Central

    Franklin, Bryony Dean; Moorthy, Krishna; Cooke, Matthew W; Vincent, Charles

    2012-01-01

    Background It is well known that many healthcare systems have poor reliability; however, the size and pervasiveness of this problem and its impact has not been systematically established in the UK. The authors studied four clinical systems: clinical information in surgical outpatient clinics, prescribing for hospital inpatients, equipment in theatres, and insertion of peripheral intravenous lines. The aim was to describe the nature, extent and variation in reliability of these four systems in a sample of UK hospitals, and to explore the reasons for poor reliability. Methods Seven UK hospital organisations were involved; each system was studied in three of these. The authors took delivery of the systems' intended outputs to be a proxy for the reliability of the system as a whole. For example, for clinical information, 100% reliability was defined as all patients having an agreed list of clinical information available when needed during their appointment. Systems factors were explored using semi-structured interviews with key informants. Common themes across the systems were identified. Results Overall reliability was found to be between 81% and 87% for the systems studied, with significant variation between organisations for some systems: clinical information in outpatient clinics ranged from 73% to 96%; prescribing for hospital inpatients 82–88%; equipment availability in theatres 63–88%; and availability of equipment for insertion of peripheral intravenous lines 80–88%. One in five reliability failures were associated with perceived threats to patient safety. Common factors causing poor reliability included lack of feedback, lack of standardisation, and issues such as access to information out of working hours. Conclusions Reported reliability was low for the four systems studied, with some common factors behind each. However, this hides significant variation between organisations for some processes, suggesting that some organisations have managed to create more reliable systems. Standardisation of processes would be expected to have significant benefit. PMID:22495099

  20. General Aviation Aircraft Reliability Study

    NASA Technical Reports Server (NTRS)

    Pettit, Duane; Turnbull, Andrew; Roelant, Henk A. (Technical Monitor)

    2001-01-01

    This reliability study was performed in order to provide the aviation community with an estimate of Complex General Aviation (GA) Aircraft System reliability. To successfully improve the safety and reliability for the next generation of GA aircraft, a study of current GA aircraft attributes was prudent. This was accomplished by benchmarking the reliability of operational Complex GA Aircraft Systems. Specifically, Complex GA Aircraft System reliability was estimated using data obtained from the logbooks of a random sample of the Complex GA Aircraft population.

  1. Applying reliability analysis to design electric power systems for More-electric aircraft

    NASA Astrophysics Data System (ADS)

    Zhang, Baozhu

    The More-Electric Aircraft (MEA) is a type of aircraft that replaces conventional hydraulic and pneumatic systems with electrically powered components. These changes have significantly challenged the aircraft electric power system design. This thesis investigates how reliability analysis can be applied to automatically generate system topologies for the MEA electric power system. We first use a traditional method of reliability block diagrams to analyze the reliability level on different system topologies. We next propose a new methodology in which system topologies, constrained by a set reliability level, are automatically generated. The path-set method is used for analysis. Finally, we interface these sets of system topologies with control synthesis tools to automatically create correct-by-construction control logic for the electric power system.

  2. Validity and Reliability of a Medicine Ball Explosive Power Test.

    ERIC Educational Resources Information Center

    Stockbrugger, Barry A.; Haennel, Robert G.

    2001-01-01

    Evaluated the validity and reliability of a medicine ball throw test to evaluate explosive power. Data on competitive sand volleyball players who performed a medicine ball throw and a standard countermovement jump indicated that the medicine ball throw test was a valid and reliable way to assess explosive power for an analogous total-body movement…

  3. The Reliability and Validity of the Instructional Climate Inventory-Student Form.

    ERIC Educational Resources Information Center

    Worrell, Frank C.

    2000-01-01

    Study examines the reliability and validity of the Instructional Climate Survey-Form S (ICI-S), a 20-item instrument that measures school climate, administered to students (N=328) in three programs. Analysis indicates that ICI-S was best explained by one factor. Reliability coeffecients of the total score were within the acceptable range for all…

  4. Design of fuel cell powered data centers for sufficient reliability and availability

    NASA Astrophysics Data System (ADS)

    Ritchie, Alexa J.; Brouwer, Jacob

    2018-04-01

    It is challenging to design a sufficiently reliable fuel cell electrical system for use in data centers, which require 99.9999% uptime. Such a system could lower emissions and increase data center efficiency, but the reliability and availability of such a system must be analyzed and understood. Currently, extensive backup equipment is used to ensure electricity availability. The proposed design alternative uses multiple fuel cell systems each supporting a small number of servers to eliminate backup power equipment provided the fuel cell design has sufficient reliability and availability. Potential system designs are explored for the entire data center and for individual fuel cells. Reliability block diagram analysis of the fuel cell systems was accomplished to understand the reliability of the systems without repair or redundant technologies. From this analysis, it was apparent that redundant components would be necessary. A program was written in MATLAB to show that the desired system reliability could be achieved by a combination of parallel components, regardless of the number of additional components needed. Having shown that the desired reliability was achievable through some combination of components, a dynamic programming analysis was undertaken to assess the ideal allocation of parallel components.

  5. Reliability modeling of fault-tolerant computer based systems

    NASA Technical Reports Server (NTRS)

    Bavuso, Salvatore J.

    1987-01-01

    Digital fault-tolerant computer-based systems have become commonplace in military and commercial avionics. These systems hold the promise of increased availability, reliability, and maintainability over conventional analog-based systems through the application of replicated digital computers arranged in fault-tolerant configurations. Three tightly coupled factors of paramount importance, ultimately determining the viability of these systems, are reliability, safety, and profitability. Reliability, the major driver affects virtually every aspect of design, packaging, and field operations, and eventually produces profit for commercial applications or increased national security. However, the utilization of digital computer systems makes the task of producing credible reliability assessment a formidable one for the reliability engineer. The root of the problem lies in the digital computer's unique adaptability to changing requirements, computational power, and ability to test itself efficiently. Addressed here are the nuances of modeling the reliability of systems with large state sizes, in the Markov sense, which result from systems based on replicated redundant hardware and to discuss the modeling of factors which can reduce reliability without concomitant depletion of hardware. Advanced fault-handling models are described and methods of acquiring and measuring parameters for these models are delineated.

  6. Reliability and Validity of a New Method for Isometric Back Extensor Strength Evaluation Using A Hand-Held Dynamometer

    PubMed Central

    2017-01-01

    Objective To investigate the reliability and validity of a new method for isometric back extensor strength measurement using a portable dynamometer. Methods A chair equipped with a small portable dynamometer was designed (Power Track II Commander Muscle Tester). A total of 15 men (mean age, 34.8±7.5 years) and 15 women (mean age, 33.1±5.5 years) with no current back problems or previous history of back surgery were recruited. Subjects were asked to push the back of the chair while seated, and their isometric back extensor strength was measured by the portable dynamometer. Test-retest reliability was assessed with intraclass correlation coefficient (ICC). For the validity assessment, isometric back extensor strength of all subjects was measured by a widely used physical performance evaluation instrument, BTE PrimusRS system. The limit of agreement (LoA) from the Bland-Altman plot was evaluated between two methods. Results The test-retest reliability was excellent (ICC=0.82; 95% confidence interval, 0.65–0.91). The Bland-Altman plots demonstrated acceptable agreement between the two methods: the lower 95% LoA was −63.1 N and the upper 95% LoA was 61.1 N. Conclusion This study shows that isometric back extensor strength measurement using a portable dynamometer has good reliability and validity. PMID:29201818

  7. Benchmarking Commercial Reliability Practices.

    DTIC Science & Technology

    1995-07-01

    companies (70% of total), and to actually receive completed survey forms from 40 companies ( 60 % of participants, 40% of total identified). Reliability...E -20 -30 - A B C D E F G H I J KL MN OP Q R -40 - A = FMEA , B = FTA, C =Thermal Analysis, D = Sneak Circuit Analysis, E = Worst-Case Circuit Analysis...Failure Modes and Effects Analysis ( FMEA ), will be conducted. c. Commercial companies specify the environmental conditions for their products. In doing

  8. Rocket engine system reliability analyses using probabilistic and fuzzy logic techniques

    NASA Technical Reports Server (NTRS)

    Hardy, Terry L.; Rapp, Douglas C.

    1994-01-01

    The reliability of rocket engine systems was analyzed by using probabilistic and fuzzy logic techniques. Fault trees were developed for integrated modular engine (IME) and discrete engine systems, and then were used with the two techniques to quantify reliability. The IRRAS (Integrated Reliability and Risk Analysis System) computer code, developed for the U.S. Nuclear Regulatory Commission, was used for the probabilistic analyses, and FUZZYFTA (Fuzzy Fault Tree Analysis), a code developed at NASA Lewis Research Center, was used for the fuzzy logic analyses. Although both techniques provided estimates of the reliability of the IME and discrete systems, probabilistic techniques emphasized uncertainty resulting from randomness in the system whereas fuzzy logic techniques emphasized uncertainty resulting from vagueness in the system. Because uncertainty can have both random and vague components, both techniques were found to be useful tools in the analysis of rocket engine system reliability.

  9. Reliability of performance of elite Olympic weightlifters.

    PubMed

    McGuigan, Michael R; Kane, Melissa K

    2004-08-01

    There are no published data on the reliability of competitive strength performance, even though it has a pronounced effect on athletes' medal prospects and the ability of coaches and athletes to identify factors that affect competitive performance. The purpose of this investigation was to analyze the reliability of elite olympic weightlifters over a series of international weightlifting meets. We obtained official results of international competitions over an 18-month period from 1999 until the 2000 Olympic Games at the International Weightlifting Federation website. The measure of reliability was the typical within-athlete variation, derived as the coefficient of variation (CV) by 2-way analysis of variance of log-transformed weights lifted for the snatch, clean and jerk, and total. The results of this analysis were (a) within-athlete variations were as follows: snatch, 2.7% (95% likely range, 2.4-3.2%); clean and jerk, 2.3% (1.7-3.6%); total weight lifted, 2.5% (2.2-2.9%); (b) men and women: the variation was higher for the women compared with the men in both snatch (ratio of CV, 1.4) and clean and jerk (ratio of CV, 1.5), and for the total weight lifted (ratio of CV, 1.3); and (c) the top 5 athletes were almost always more reliable than the bottom-half athletes. Recent work has shown that the smallest worthwhile performance is about half the within-athlete variation, so coaches and sport scientists should focus on enhancements of as little as 1.2% in total weight lifted for elite olympic weightlifters.

  10. Solar-Diesel Hybrid Power System Optimization and Experimental Validation

    NASA Astrophysics Data System (ADS)

    Jacobus, Headley Stewart

    As of 2008 1.46 billion people, or 22 percent of the World's population, were without electricity. Many of these people live in remote areas where decentralized generation is the only method of electrification. Most mini-grids are powered by diesel generators, but new hybrid power systems are becoming a reliable method to incorporate renewable energy while also reducing total system cost. This thesis quantifies the measurable Operational Costs for an experimental hybrid power system in Sierra Leone. Two software programs, Hybrid2 and HOMER, are used during the system design and subsequent analysis. Experimental data from the installed system is used to validate the two programs and to quantify the savings created by each component within the hybrid system. This thesis bridges the gap between design optimization studies that frequently lack subsequent validation and experimental hybrid system performance studies.

  11. Plug nozzles: The ultimate customer driven propulsion system

    NASA Technical Reports Server (NTRS)

    Aukerman, Carl A.

    1991-01-01

    This paper presents the results of a study applying the plug cluster nozzle concept to the propulsion system for a typical lunar excursion vehicle. Primary attention for the design criteria is given to user defined factors such as reliability, low volume, and ease of propulsion system development. Total thrust and specific impulse are held constant in the study while other parameters are explored to minimize the design chamber pressure. A brief history of the plug nozzle concept is included to point out the advanced level of technology of the concept and the feasibility of exploiting the variables considered in this study. The plug cluster concept looks very promising as a candidate for consideration for the ultimate customer driven propulsion system.

  12. Plug nozzles - The ultimate customer driven propulsion system. [applied to manned lunar and Martian landers

    NASA Technical Reports Server (NTRS)

    Aukerman, Carl A.

    1991-01-01

    This paper presents the results of a study applying the plug cluster nozzle concept to the propulsion system for a typical lunar excursion vehicle. Primary attention for the design criteria is given to user defined factors such as reliability, low volume, and ease of propulsion system development. Total thrust and specific impulse are held constant in the study while other parameters are explored to minimize the design chamber pressure. A brief history of the plug nozzle concept is included to point out the advanced level of technology of the concept and the feasibility of exploiting the variables considered in the study. The plug cluster concept looks very promising as a candidate for consideration for the ultimate customer driven propulsion system.

  13. Centralized vs decentralized lunar power system study

    NASA Astrophysics Data System (ADS)

    Metcalf, Kenneth; Harty, Richard B.; Perronne, Gerald E.

    1991-09-01

    Three power-system options are considered with respect to utilization on a lunar base: the fully centralized option, the fully decentralized option, and a hybrid comprising features of the first two options. Power source, power conditioning, and power transmission are considered separately, and each architecture option is examined with ac and dc distribution, high and low voltage transmission, and buried and suspended cables. Assessments are made on the basis of mass, technological complexity, cost, reliability, and installation complexity, however, a preferred power-system architecture is not proposed. Preferred options include transmission based on ac, transmission voltages of 2000-7000 V with buried high-voltage lines and suspended low-voltage lines. Assessments of the total cost associated with the installations are required to determine the most suitable power system.

  14. A pumped, two-phase flow heat transport system for orbiting instrument payloads

    NASA Technical Reports Server (NTRS)

    Fowle, A. A.

    1981-01-01

    A pumped two-phase (heat absorption/heat rejection) thermal transport system for orbiting instrument payloads is investigated. The thermofluid characteristics necessary for the system design are discussed. A preliminary design with a series arrangement of four instrument heat stations and six radiators in a single loop is described in detail, and the total mass is estimated to be 134 kg, with the radiators, instrument heat stations, and fluid reservoir accounting for approximately 86, 24, and 12 kg, respectively. The evaluation of preliminary test results shows that the system has potential advantages; however, further research is necessary in the areas of one-g and zero-g heat transfer coefficients/fluid regimes, fluid by-pass temperature control, and reliability of small pumps.

  15. Reliability of Fault Tolerant Control Systems. Part 1

    NASA Technical Reports Server (NTRS)

    Wu, N. Eva

    2001-01-01

    This paper reports Part I of a two part effort, that is intended to delineate the relationship between reliability and fault tolerant control in a quantitative manner. Reliability analysis of fault-tolerant control systems is performed using Markov models. Reliability properties, peculiar to fault-tolerant control systems are emphasized. As a consequence, coverage of failures through redundancy management can be severely limited. It is shown that in the early life of a syi1ein composed of highly reliable subsystems, the reliability of the overall system is affine with respect to coverage, and inadequate coverage induces dominant single point failures. The utility of some existing software tools for assessing the reliability of fault tolerant control systems is also discussed. Coverage modeling is attempted in Part II in a way that captures its dependence on the control performance and on the diagnostic resolution.

  16. Operational Challenges In TDRS Post-Maneuver Orbit Determination

    NASA Technical Reports Server (NTRS)

    Laing, Jason; Myers, Jessica; Ward, Douglas; Lamb, Rivers

    2015-01-01

    The GSFC Flight Dynamics Facility (FDF) is responsible for daily and post maneuver orbit determination for the Tracking and Data Relay Satellite System (TDRSS). The most stringent requirement for this orbit determination is 75 meters total position accuracy (3-sigma) predicted over one day for Terra's onboard navigation system. To maintain an accurate solution onboard Terra, a solution is generated and provided by the FDF Four hours after a TDRS maneuver. A number of factors present challenges to this support, such as maneuver prediction uncertainty and potentially unreliable tracking from User satellities. Reliable support is provided by comparing an extended Kalman Filter (estimated using ODTK) against a Batch Least Squares system (estimated using GTDS).

  17. Dynamic decision-making for reliability and maintenance analysis of manufacturing systems based on failure effects

    NASA Astrophysics Data System (ADS)

    Zhang, Ding; Zhang, Yingjie

    2017-09-01

    A framework for reliability and maintenance analysis of job shop manufacturing systems is proposed in this paper. An efficient preventive maintenance (PM) policy in terms of failure effects analysis (FEA) is proposed. Subsequently, reliability evaluation and component importance measure based on FEA are performed under the PM policy. A job shop manufacturing system is applied to validate the reliability evaluation and dynamic maintenance policy. Obtained results are compared with existed methods and the effectiveness is validated. Some vague understandings for issues such as network modelling, vulnerabilities identification, the evaluation criteria of repairable systems, as well as PM policy during manufacturing system reliability analysis are elaborated. This framework can help for reliability optimisation and rational maintenance resources allocation of job shop manufacturing systems.

  18. Reliability analysis and initial requirements for FC systems and stacks

    NASA Astrophysics Data System (ADS)

    Åström, K.; Fontell, E.; Virtanen, S.

    In the year 2000 Wärtsilä Corporation started an R&D program to develop SOFC systems for CHP applications. The program aims to bring to the market highly efficient, clean and cost competitive fuel cell systems with rated power output in the range of 50-250 kW for distributed generation and marine applications. In the program Wärtsilä focuses on system integration and development. System reliability and availability are key issues determining the competitiveness of the SOFC technology. In Wärtsilä, methods have been implemented for analysing the system in respect to reliability and safety as well as for defining reliability requirements for system components. A fault tree representation is used as the basis for reliability prediction analysis. A dynamic simulation technique has been developed to allow for non-static properties in the fault tree logic modelling. Special emphasis has been placed on reliability analysis of the fuel cell stacks in the system. A method for assessing reliability and critical failure predictability requirements for fuel cell stacks in a system consisting of several stacks has been developed. The method is based on a qualitative model of the stack configuration where each stack can be in a functional, partially failed or critically failed state, each of the states having different failure rates and effects on the system behaviour. The main purpose of the method is to understand the effect of stack reliability, critical failure predictability and operating strategy on the system reliability and availability. An example configuration, consisting of 5 × 5 stacks (series of 5 sets of 5 parallel stacks) is analysed in respect to stack reliability requirements as a function of predictability of critical failures and Weibull shape factor of failure rate distributions.

  19. A reliability analysis tool for SpaceWire network

    NASA Astrophysics Data System (ADS)

    Zhou, Qiang; Zhu, Longjiang; Fei, Haidong; Wang, Xingyou

    2017-04-01

    A SpaceWire is a standard for on-board satellite networks as the basis for future data-handling architectures. It is becoming more and more popular in space applications due to its technical advantages, including reliability, low power and fault protection, etc. High reliability is the vital issue for spacecraft. Therefore, it is very important to analyze and improve the reliability performance of the SpaceWire network. This paper deals with the problem of reliability modeling and analysis with SpaceWire network. According to the function division of distributed network, a reliability analysis method based on a task is proposed, the reliability analysis of every task can lead to the system reliability matrix, the reliability result of the network system can be deduced by integrating these entire reliability indexes in the matrix. With the method, we develop a reliability analysis tool for SpaceWire Network based on VC, where the computation schemes for reliability matrix and the multi-path-task reliability are also implemented. By using this tool, we analyze several cases on typical architectures. And the analytic results indicate that redundancy architecture has better reliability performance than basic one. In practical, the dual redundancy scheme has been adopted for some key unit, to improve the reliability index of the system or task. Finally, this reliability analysis tool will has a directive influence on both task division and topology selection in the phase of SpaceWire network system design.

  20. Environmental Control and Life Support System Reliability for Long-Duration Missions Beyond Lower Earth Orbit

    NASA Technical Reports Server (NTRS)

    Sargusingh, Miriam J.; Nelson, Jason R.

    2014-01-01

    NASA has highlighted reliability as critical to future human space exploration, particularly in the area of environmental controls and life support systems. The Advanced Exploration Systems (AES) projects have been encouraged to pursue higher reliability components and systems as part of technology development plans. However, no consensus has been reached on what is meant by improving on reliability, or on how to assess reliability within the AES projects. This became apparent when trying to assess reliability as one of several figures of merit for a regenerable water architecture trade study. In the spring of 2013, the AES Water Recovery Project hosted a series of events at Johnson Space Center with the intended goal of establishing a common language and understanding of NASA's reliability goals, and equipping the projects with acceptable means of assessing the respective systems. This campaign included an educational series in which experts from across the agency and academia provided information on terminology, tools, and techniques associated with evaluating and designing for system reliability. The campaign culminated in a workshop that included members of the Environmental Control and Life Support System and AES communities. The goal of this workshop was to develop a consensus on what reliability means to AES and identify methods for assessing low- to mid-technology readiness level technologies for reliability. This paper details the results of that workshop.

  1. Reliability and Validity of the Greek Migraine Disability Assessment (MIDAS) Questionnaire.

    PubMed

    Oikonomidi, Theodora; Vikelis, Michail; Artemiadis, Artemios; Chrousos, George P; Darviri, Christina

    2018-03-01

    The Migraine Disability Assessment (MIDAS) Questionnaire is a reliable and valid instrument for migraine-related disability. Such a tool is needed to quantify migraine-related disability in the Greek population. This validation study aims to assess the test-retest reliability, internal consistency, item discriminant and convergent validity of the Greek translation of the MIDAS. Adults diagnosed with migraine completed the MIDAS Questionnaire on two occasions 3 weeks apart to assess reliability, and completed the RAND-36 to assess validity. Participants (n = 152) had a median MIDAS score of 24 and mostly severe disability (58% were grade IV). The test-retest reliability analysis (N = 59) revealed excellent reliability for the total score. Internal consistency was α = 0.71 for initial and α = 0.82 for retest completion. For item discriminant validity, the correlations between each question and the total score were significant, with high correlations for questions 2-5 (range 0.67 ≤ r ≤ 0.79; p < 0.01). For convergent validity, there was significant negative correlation between the total score and all RAND-36 subscales except for 'emotional wellbeing'. The negative correlation indicates that patients with a lower degree of disability according to their MIDAS score tended to have better wellbeing. Psychometric properties are comparable with those of other published validation studies of the MIDAS and the original. Findings on question 1 show that missing work/school days may be closely related with increased affect issues. The Greek version of the MIDAS Questionnaire has good reliability and validity. This study allowed for cross-cultural comparability of research findings.

  2. Non-contact ulcer area calculation system for neuropathic foot ulcer.

    PubMed

    Shah, Parth; Mahajan, Siddaram; Nageswaran, Sharmila; Paul, Sathish Kumar; Ebenzer, Mannam

    2017-08-11

    Around 125,785 new cases in year 2013-14 of leprosy were detected in India as per WHO report on leprosy in September 2015 which accounts to approximately 62% of the total new cases. Anaesthetic foot caused by leprosy leads to uneven loading of foot leading to ulcer in approximately 20% of the cases. Much efforts have gone in identifying newer techniques to efficiently monitor the progress of ulcer healing. Current techniques followed in measuring the size of ulcers, have not been found to be so accurate but are still is followed by clinicians across the globe. Quantification of prognosis of the condition would be required to understand the efficacy of current treatment methods and plan for further treatment. This study aims at developing a non contact technique to precisely measure the size of ulcer in patients affected by leprosy. Using MATLAB software, GUI was designed to process the acquired ulcer image by segmenting and calculating the pixel area of the image. The image was further converted to a standard measurement using a reference object. The developed technique was tested on 16 ulcer images acquired from 10 leprosy patients with plantar ulcers. Statistical analysis was done using MedCalc analysis software to find the reliability of the system. The analysis showed a very high correlation coefficient (r=0.9882) between the ulcer area measurements done using traditional technique and the newly developed technique, The reliability of the newly developed technique was significant with a significance level of 99.9%. The designed non-contact ulcer area calculating system using MATLAB is found to be a reliable system in calculating the size of ulcers. The technique would help clinicians have a reliable tool to monitor the progress of ulcer healing and help modify the treatment protocol if needed. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  3. 2D and 3D MOCART scoring systems assessed by 9.4 T high-field MRI correlate with elementary and complex histological scoring systems in a translational model of osteochondral repair.

    PubMed

    Goebel, L; Zurakowski, D; Müller, A; Pape, D; Cucchiarini, M; Madry, H

    2014-10-01

    To compare the 2D and 3D MOCART system obtained with 9.4 T high-field magnetic resonance imaging (MRI) for the ex vivo analysis of osteochondral repair in a translational model and to correlate the data with semiquantitative histological analysis. Osteochondral samples representing all levels of repair (sheep medial femoral condyles; n = 38) were scanned in a 9.4 T high-field MRI. The 2D and adapted 3D MOCART systems were used for grading after point allocation to each category. Each score was correlated with corresponding reconstructions between both MOCART systems. Data were next correlated with corresponding categories of an elementary (Wakitani) and a complex (Sellers) histological scoring system as gold standards. Correlations between most 2D and 3D MOCART score categories were high, while mean total point values of 3D MOCART scores tended to be 15.8-16.1 points higher compared to the 2D MOCART scores based on a Bland-Altman analysis. "Defect fill" and "total points" of both MOCART scores correlated with corresponding categories of Wakitani and Sellers scores (all P ≤ 0.05). "Subchondral bone plate" also correlated between 3D MOCART and Sellers scores (P < 0.001). Most categories of the 2D and 3D MOCART systems correlate, while total scores were generally higher using the 3D MOCART system. Structural categories "total points" and "defect fill" can reliably be assessed by 9.4 T MRI evaluation using either system, "subchondral bone plate" using the 3D MOCART score. High-field MRI is valuable to objectively evaluate osteochondral repair in translational settings. Copyright © 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  4. Performance of an off-grid solar home in northwestern Vermont

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rawlings, L.K.

    1997-12-31

    In 1995 an off-grid integrated solar home was built in Middlesex, VT for Peter Clark and Gloria DeSousa. This home was included as a pilot home in the US DOE PV:BONUS program to develop factory-built integrated solar homes. The home incorporates a 1.44 KW PV system, 0.6 KW of wind turbine capacity, and very high-efficiency electrical loads. The home also features passive solar design, high-efficiency heating systems, and a greenhouse-based septic treatment system. The performance of the PV system and the wind system, and the total power usage of the household, are measured and recorded by a data acquisition system.more » The home`s electrical loads have operated very efficiently, using on average about one tenth the power used by the average American residence. The PV system has operated reliably and efficiently, providing about 97% of the power needs of the home. The wind turbines have operated efficiently, but the wind regime at the site has not been sufficient to generate more than 1% of the total power needs. The other 2% has been provided by a gasoline backup generator.« less

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bollinger, J.M.; Kaplan, N.; Wilkening, H.A. Jr.

    AAI Corporation designed, constructed, and operated a solar heating system to provide hot water for curing concrete blocks at the York Building Products Co., Inc.'s new manufacturing facility near Harrisburg, PA. The objective of Phase III of this program was to operate, collect data, and evaluate the solar system for a three-year period. The solar facility utilizes 35 collectors with a total aperture area of 8,960 ft/sup 2/. The system is designed to deliver a water/ethylene glycol solution at 200/sup 0/F to a heat exchanger, which, in turn, supplies water at 180/sup 0/F to a rotoclave (underground tank) for themore » concrete-block curing process. A fossil-fuel boiler system also supplies the rotoclave with processed hot water to supplement the solar system. The system was operational 92.5% of the days during which the data acquisition system was functional. Sufficient solar heating was available to deliver hot water to the heat exchanger on 448 days, or 81.8% of the days on which reliable data was recorded. Total fuel saved during the three-year period was 10,284 gallons. Thus, this program has successfully demonstrated the technical feasibility of generating industrial process hot water with solar energy.« less

  6. Manual muscle testing and hand-held dynamometry in people with inflammatory myopathy: An intra- and interrater reliability and validity study

    PubMed Central

    Baschung Pfister, Pierrette; Sterkele, Iris; Maurer, Britta; de Bie, Rob A.; Knols, Ruud H.

    2018-01-01

    Manual muscle testing (MMT) and hand-held dynamometry (HHD) are commonly used in people with inflammatory myopathy (IM), but their clinimetric properties have not yet been sufficiently studied. To evaluate the reliability and validity of MMT and HHD, maximum isometric strength was measured in eight muscle groups across three measurement events. To evaluate reliability of HHD, intra-class correlation coefficients (ICC), the standard error of measurements (SEM) and smallest detectable changes (SDC) were calculated. To measure reliability of MMT linear Cohen`s Kappa was computed for single muscle groups and ICC for total score. Additionally, correlations between MMT8 and HHD were evaluated with Spearman Correlation Coefficients. Fifty people with myositis (56±14 years, 76% female) were included in the study. Intra-and interrater reliability of HHD yielded excellent ICCs (0.75–0.97) for all muscle groups, except for interrater reliability of ankle extension (0.61). The corresponding SEMs% ranged from 8 to 28% and the SDCs% from 23 to 65%. MMT8 total score revealed excellent intra-and interrater reliability (ICC>0.9). Intrarater reliability of single muscle groups was substantial for shoulder and hip abduction, elbow and neck flexion, and hip extension (0.64–0.69); moderate for wrist (0.53) and knee extension (0.49) and fair for ankle extension (0.35). Interrater reliability was moderate for neck flexion (0.54) and hip abduction (0.44); fair for shoulder abduction, elbow flexion, wrist and ankle extension (0.20–0.33); and slight for knee extension (0.08). Correlations between the two tests were low for wrist, knee, ankle, and hip extension; moderate for elbow flexion, neck flexion and hip abduction; and good for shoulder abduction. In conclusion, the MMT8 total score is a reliable assessment to consider general muscle weakness in people with myositis but not for single muscle groups. In contrast, our results confirm that HHD can be recommended to evaluate strength of single muscle groups. PMID:29596450

  7. Space Shuttle Propulsion System Reliability

    NASA Technical Reports Server (NTRS)

    Welzyn, Ken; VanHooser, Katherine; Moore, Dennis; Wood, David

    2011-01-01

    This session includes the following sessions: (1) External Tank (ET) System Reliability and Lessons, (2) Space Shuttle Main Engine (SSME), Reliability Validated by a Million Seconds of Testing, (3) Reusable Solid Rocket Motor (RSRM) Reliability via Process Control, and (4) Solid Rocket Booster (SRB) Reliability via Acceptance and Testing.

  8. Functional leg length discrepancy between theories and reliable instrumental assessment: a study about newly invented NPoS system.

    PubMed

    Mahmoud, Asmaa; Abundo, Paolo; Basile, Luisanna; Albensi, Caterina; Marasco, Morena; Bellizzi, Letizia; Galasso, Franco; Foti, Calogero

    2017-01-01

    In spite the instinct social&financial impact of Leg Length Discrepancy (LLD), controversial and conflicting results still exist regarding a reliable assessment/correction method. For proper management it's essential to discriminate between anatomical&functional Leg Length Discrepancy (FLLD). With the newly invented NPoS (New Postural Solution), under the umbrella of the collaboration of PRM Department, Tor Vergata University with Baro Postural Instruments srl, positive results were observed in both measuring& compensating the hemi-pelvic antero-medial rotation in FLLD through personalized bilateral heel raise using two NPoS components: Foot Image System (FIS) and Postural Optimizer System (POS). This led our research interest to test the validity of NPoS as a preliminary step before evaluating its implementations in postural disorders. After clinical evaluation, 4 subjects with FLLD have been assessed by NPoS. Over a period of 2 months, every subject was evaluated 12 times by two different operators, 48 measurements in total, results have been verified in correlation to BTS GaitLab results. Intra-Operator&inter-operator variability analysis showed statistically insignificant differences, while inter-method variability between NPoS and BTS parameters expressed a linear correlation. Results suggest a significant validity of NPoS in assessment&correction of FLLD, with high degree of reproducibility with minimal operator dependency. This can be considered a base for promising clinical implications of NPoS as a reliable cost effective postural assessment/corrective tool. V.

  9. Demand response, behind-the-meter generation and air quality.

    PubMed

    Zhang, Xiyue; Zhang, K Max

    2015-02-03

    We investigated the implications of behind-the-meter (BTM) generation participating in demand response (DR) programs. Specifically, we evaluated the impacts of NOx emissions from BTM generators enrolled in the New York Independent System Operator (NYISO)'s reliability-based DR programs. Through analyzing the DR program enrollment data, DR event records, ozone air quality monitoring data, and emission characteristics of the generators, we found that the emissions from BTM generators very likely contribute to exceedingly high ozone concentrations in the Northeast Corridor region, and very likely account for a substantial fraction of total NOx emissions from electricity generation. In addition, a companion study showed that the emissions from BTM generators could also form near-source particulate matter (PM) hotspots. The important policy implications are that the absence of up-to-date regulations on BTM generators may offset the current efforts to reduce the emissions from peaking power plants, and that there is a need to quantify the environmental impacts of DR programs in designing sound policies related to demand-side resources. Furthermore, we proposed the concept of "Green" DR resources, referring to those that not only provide power systems reliability services, but also have verifiable environmental benefits or minimal negative environmental impacts. We argue that Green DR resources that are able to maintain resource adequacy and reduce emissions at the same time are key to achieving the cobenefits of power system reliability and protecting public health during periods with peak electricity demand.

  10. Identification of Classified Information in Unclassified DoD Systems During the Audit of Internal Controls and Data Reliability in the Deployable Disbursing System

    DTIC Science & Technology

    2009-02-17

    Identification of Classified Information in Unclassified DoD Systems During the Audit of Internal Controls and Data Reliability in the Deployable...TITLE AND SUBTITLE Identification of Classified Information in Unclassified DoD Systems During the Audit of Internal Controls and Data Reliability...Systems During the Audit ofInternal Controls and Data Reliability in the Deployable Disbursing System (Report No. D-2009-054) Weare providing this

  11. Performance of Gout Impact Scale in a longitudinal observational study of patients with gout

    PubMed Central

    Wallace, Beth; Khanna, Dinesh; Aquino-Beaton, Cleopatra; Singh, Jasvinder A.; Duffy, Erin; Elashoff, David

    2016-01-01

    Abstract Objective. The aim was to evaluate the reliability, validity and responsiveness to change of the Gout Impact Scale (GIS), a disease-specific measure of patient-reported outcomes, in a multicentre longitudinal prospective cohort of gout patients. Methods. Subjects completed the GIS, a 24-item instrument with five scales: Concern Overall, Medication Side Effects, Unmet Treatment Need, Well-Being during Attack, and Concern Over Attack. The total GIS score was calculated by averaging the GIS scale scores. HAQ-Disability Index (HAQ-DI), Short Form (SF)-36 physical and mental component summaries (PCS and MCS) and physician and patient gout severity assessments were also completed. Reliability was assessed with Cronbach’s α. Baseline GIS scores were compared in subjects with and without gout attacks in the past 3 months using Wilcoxon rank sum tests. Multivariate linear regression was used to evaluate predictors of total GIS. Pearson’s correlation coefficients 0.24–0.36 were considered moderate and >0.37 considered large. The effect size for responsiveness to change was interpreted as follows: 0.20–0.49 small, 0.50–0.79 medium and >0.79 large. Results. In 147 subjects, reliability was acceptable for total GIS (0.93) and all GIS scales (0.82–0.94) except Medication Side Effects and Unmet Treatment Need. Total GIS and all scales except Medication Side Effects discriminated between subjects with and without recent gout attacks (P < 0.05). Total GIS showed moderate-to-large correlations with HAQ-DI, SF-36 PCS and MCS (0.33–0.46). Improvement in total GIS tracked with improved physician and patient severity scores. Worsening physician severity score and recent gout attack predicted worsening total GIS. Conclusion. Total GIS score is reliable, valid and responsive to change in patients with gout, and differentiates between subjects with and without recent gout attacks. PMID:26888852

  12. Emulation applied to reliability analysis of reconfigurable, highly reliable, fault-tolerant computing systems

    NASA Technical Reports Server (NTRS)

    Migneault, G. E.

    1979-01-01

    Emulation techniques applied to the analysis of the reliability of highly reliable computer systems for future commercial aircraft are described. The lack of credible precision in reliability estimates obtained by analytical modeling techniques is first established. The difficulty is shown to be an unavoidable consequence of: (1) a high reliability requirement so demanding as to make system evaluation by use testing infeasible; (2) a complex system design technique, fault tolerance; (3) system reliability dominated by errors due to flaws in the system definition; and (4) elaborate analytical modeling techniques whose precision outputs are quite sensitive to errors of approximation in their input data. Next, the technique of emulation is described, indicating how its input is a simple description of the logical structure of a system and its output is the consequent behavior. Use of emulation techniques is discussed for pseudo-testing systems to evaluate bounds on the parameter values needed for the analytical techniques. Finally an illustrative example is presented to demonstrate from actual use the promise of the proposed application of emulation.

  13. HiRel: Hybrid Automated Reliability Predictor (HARP) integrated reliability tool system, (version 7.0). Volume 4: HARP Output (HARPO) graphics display user's guide

    NASA Technical Reports Server (NTRS)

    Sproles, Darrell W.; Bavuso, Salvatore J.

    1994-01-01

    The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of highly reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed at the outset to be compatible with most computing platforms and operating systems and some programs have been beta tested within the aerospace community for over 8 years. This document is a user's guide for the HiRel graphical postprocessor program HARPO (HARP Output). HARPO reads ASCII files generated by HARP. It provides an interactive plotting capability that can be used to display alternate model data for trade-off analyses. File data can also be imported to other commercial software programs.

  14. Propulsion simulation test technique for V/STOL configurations

    NASA Technical Reports Server (NTRS)

    Bailey, R. O.; Smith, S. C.; Bustie, J. B.

    1983-01-01

    Ames Research Center is developing the technology for turbine-powered jet engine simulators so that airframe/propulsion system interactions on V/STOL fighter aircraft and other highly integrated configurations can be studied. This paper describes the status of the compact multimission aircraft propulsion simulator (CMAPS) technology. Three CMAPS units have accumulated a total of 340 hr during approximately 1-1/2 yr of static and wind-tunnel testing. A wind-tunnel test of a twin-engine CMAPS-equipped close-coupled canard-wing V/STOL model configuration with nonaxisymmetric nozzles was recently completed. During this test approximately 140 total hours were logged on two CMAPS units, indicating that the rotating machinery is reliable and that the CMAPS and associated control system provide a usable test tool. However, additional development is required to correct a drive manifold O-ring problem that limits the engine-pressure-ratio (EPR) to approximately 3.5.

  15. 18 CFR 39.3 - Electric Reliability Organization certification.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... operators of the Bulk-Power System, and other interested parties for improvement of the Electric Reliability... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Electric Reliability..., Reliability Standards that provide for an adequate level of reliability of the Bulk-Power System, and (2) Has...

  16. Efficacy of computer-based endoscope cleaning and disinfection using a hospital management information system.

    PubMed

    Wang, Caixia; Chen, Yuanyuan; Yang, Feng; Ren, Jie; Yu, Xin; Wang, Jiani; Sun, Siyu

    2016-08-01

    The present study aimed to assess the efficacy of computer-based endoscope cleaning and disinfection using a hospital management information system (HMIS). A total of 2,674 gastroscopes were eligible for inclusion in this study. For the processes of disinfection management, the gastroscopes were randomly divided into 2 groups: gastroscope disinfection HMIS (GD-HMIS) group and manual group. In the GD-HMIS group, an integrated circuit card (IC card) chip was installed to monitor and record endoscope cleaning and disinfection automatically and in real time, whereas the endoscope cleaning and disinfection in the manual group was recorded manually. The overall disinfection progresses for both groups were recorded, and the total operational time was calculated. For the GD-HMIS group, endoscope disinfection HMIS software was successfully developed. The time to complete a single session of cleaning and disinfecting on a gastroscope was 15.6 minutes (range, 14.3-17.2 minutes) for the GD-HMIS group and 21.3 minutes (range, 20.2-23.9 minutes) for the manual group. Failure to record information, such as the identification number of the endoscope, occasionally occurred in the manual group, which affected the accuracy and reliability of manual recording. Computer-based gastroscope cleaning and disinfection using a hospital management information system could monitor the process of gastroscope cleaning and disinfection in real time and improve the accuracy and reliability, thereby ensuring the quality of gastroscope cleaning and disinfection. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  17. 78 FR 44475 - Protection System Maintenance Reliability Standard

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-24

    ... Protection System Maintenance--Phase 2 (Reclosing Relays)). 12. NERC states that the proposed Reliability... of the relay inputs and outputs that are essential to proper functioning of the protection system...] Protection System Maintenance Reliability Standard AGENCY: Federal Energy Regulatory Commission, Energy...

  18. Methods for Calculating Frequency of Maintenance of Complex Information Security System Based on Dynamics of Its Reliability

    NASA Astrophysics Data System (ADS)

    Varlataya, S. K.; Evdokimov, V. E.; Urzov, A. Y.

    2017-11-01

    This article describes a process of calculating a certain complex information security system (CISS) reliability using the example of the technospheric security management model as well as ability to determine the frequency of its maintenance using the system reliability parameter which allows one to assess man-made risks and to forecast natural and man-made emergencies. The relevance of this article is explained by the fact the CISS reliability is closely related to information security (IS) risks. Since reliability (or resiliency) is a probabilistic characteristic of the system showing the possibility of its failure (and as a consequence - threats to the protected information assets emergence), it is seen as a component of the overall IS risk in the system. As it is known, there is a certain acceptable level of IS risk assigned by experts for a particular information system; in case of reliability being a risk-forming factor maintaining an acceptable risk level should be carried out by the routine analysis of the condition of CISS and its elements and their timely service. The article presents a reliability parameter calculation for the CISS with a mixed type of element connection, a formula of the dynamics of such system reliability is written. The chart of CISS reliability change is a S-shaped curve which can be divided into 3 periods: almost invariable high level of reliability, uniform reliability reduction, almost invariable low level of reliability. Setting the minimum acceptable level of reliability, the graph (or formula) can be used to determine the period of time during which the system would meet requirements. Ideally, this period should not be longer than the first period of the graph. Thus, the proposed method of calculating the CISS maintenance frequency helps to solve a voluminous and critical task of the information assets risk management.

  19. Power source selection for neutral particle beam systems

    NASA Astrophysics Data System (ADS)

    Silverman, Sidney W.; Chi, John W. H.; Hill, Gregory

    Space based neutral particle beams (NPB) are being considered for use as an SDI weapon as well as a mid-course discriminator. These systems require a radio frequency (RF) power source. Five types of amplifiers were considered for the RF power source: the klystron, the klystrode, the tetrode, the cross field amplifier, and the solid state amplifier. A number of different types of power source systems (nuclear and non-nuclear) were considered for integration with these amplifiers. The most attractive amplifier power system concepts were identified through comparative evaluations that took into account the total masses of integrated amplifier power source systems as well as a number of other factors that consisted of development cost, technology risk, vulnerability, survivability, reliability, and impacts on spacecraft stabilization. These concepts are described and conclusions drawn.

  20. Reliability testing of the Larsen and Sharp classifications for rheumatoid arthritis of the elbow.

    PubMed

    Jew, Nicholas B; Hollins, Anthony M; Mauck, Benjamin M; Smith, Richard A; Azar, Frederick M; Miller, Robert H; Throckmorton, Thomas W

    2017-01-01

    Two popular systems for classifying rheumatoid arthritis affecting the elbow are the Larsen and Sharp schemes. To our knowledge, no study has investigated the reliability of these 2 systems. We compared the intraobserver and interobserver agreement of the 2 systems to determine whether one is more reliable than the other. The radiographs of 45 patients diagnosed with rheumatoid arthritis affecting the elbow were evaluated. Anteroposterior and lateral radiographs were deidentified and distributed to 6 evaluators (4 fellowship-trained upper extremity surgeons and 2 orthopedic trainees). Each evaluator graded all 45 radiographs according to the Larsen and Sharp scoring methods on 2 occasions, at least 2 weeks apart. Overall intraobserver reliability was 0.93 (95% confidence interval [CI], 0.90-0.95) for the Larsen system and 0.92 (95% CI, 0.86-0.96) for the Sharp classification, both indicating substantial agreement. Overall interobserver reliability was 0.70 (95% CI, 0.60-0.80) for the Larsen classification and 0.68 (95% CI, 0.54-0.81) for the Sharp system, both indicating good agreement. There were no significant differences in the intraobserver or interobserver reliability of the systems overall and no significant differences in reliability between attending surgeons and trainees for either classification system. The Larsen and Sharp systems both show substantial intraobserver reliability and good interobserver agreement for the radiographic classification of rheumatoid arthritis affecting the elbow. Differences in training level did not result in substantial variances in reliability for either system. We conclude that both systems can be reliably used to evaluate rheumatoid arthritis of the elbow by observers of varying training levels. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  1. Perspective: NutriGrade: A Scoring System to Assess and Judge the Meta-Evidence of Randomized Controlled Trials and Cohort Studies in Nutrition Research.

    PubMed

    Schwingshackl, Lukas; Knüppel, Sven; Schwedhelm, Carolina; Hoffmann, Georg; Missbach, Benjamin; Stelmach-Mardas, Marta; Dietrich, Stefan; Eichelmann, Fabian; Kontopantelis, Evangelos; Iqbal, Khalid; Aleksandrova, Krasimira; Lorkowski, Stefan; Leitzmann, Michael F; Kroke, Anja; Boeing, Heiner

    2016-11-01

    The objective of this study was to develop a scoring system (NutriGrade) to evaluate the quality of evidence of randomized controlled trial (RCT) and cohort study meta-analyses in nutrition research, building upon previous tools and expert recommendations. NutriGrade aims to assess the meta-evidence of an association or effect between different nutrition factors and outcomes, taking into account nutrition research-specific requirements not considered by other tools. In a pretest study, 6 randomly selected meta-analyses investigating diet-disease relations were evaluated with NutriGrade by 5 independent raters. After revision, NutriGrade was applied by the same raters to 30 randomly selected meta-analyses in the same thematic area. The reliability of ratings of NutriGrade items was calculated with the use of a multirater κ, and reliability of the total (summed scores) was calculated with the use of intraclass correlation coefficients (ICCs). The following categories for meta-evidence evaluation were established: high (8-10), moderate (6-7.99), low (4-5.99), and very low (0-3.99). The NutriGrade scoring system (maximum of 10 points) comprises the following items: 1) risk of bias, study quality, and study limitations, 2) precision, 3) heterogeneity, 4) directness, 5) publication bias, 6) funding bias, 7) study design, 8) effect size, and 9) dose-response. The NutriGrade score varied between 2.9 (very low meta-evidence) and 8.8 (high meta-evidence) for meta-analyses of RCTs, and it ranged between 3.1 and 8.8 for meta-analyses of cohort studies. The κ value of the ratings for each scoring item varied from 0.32 (95% CI: 0.22, 0.42) for risk of bias for cohort studies and 0.95 (95% CI: 0.91, 0.99) for study design, with a mean κ of 0.66 (95% CI: 0.53, 0.79). The ICC of the total score was 0.81 (95% CI: 0.69, 0.90). The NutriGrade scoring system showed good agreement and reliability. The initial findings regarding the performance of this newly established scoring system need further evaluation in independent analyses. © 2016 American Society for Nutrition.

  2. Perspective: NutriGrade: A Scoring System to Assess and Judge the Meta-Evidence of Randomized Controlled Trials and Cohort Studies in Nutrition Research123

    PubMed Central

    Knüppel, Sven; Schwedhelm, Carolina; Hoffmann, Georg; Missbach, Benjamin; Stelmach-Mardas, Marta; Dietrich, Stefan; Eichelmann, Fabian; Kontopanteils, Evangelos; Iqbal, Khalid; Aleksandrova, Krasimira; Lorkowski, Stefan; Leitzmann, Michael F; Kroke, Anja; Boeing, Heiner

    2016-01-01

    The objective of this study was to develop a scoring system (NutriGrade) to evaluate the quality of evidence of randomized controlled trial (RCT) and cohort study meta-analyses in nutrition research, building upon previous tools and expert recommendations. NutriGrade aims to assess the meta-evidence of an association or effect between different nutrition factors and outcomes, taking into account nutrition research–specific requirements not considered by other tools. In a pretest study, 6 randomly selected meta-analyses investigating diet–disease relations were evaluated with NutriGrade by 5 independent raters. After revision, NutriGrade was applied by the same raters to 30 randomly selected meta-analyses in the same thematic area. The reliability of ratings of NutriGrade items was calculated with the use of a multirater κ, and reliability of the total (summed scores) was calculated with the use of intraclass correlation coefficients (ICCs). The following categories for meta-evidence evaluation were established: high (8–10), moderate (6–7.99), low (4–5.99), and very low (0–3.99). The NutriGrade scoring system (maximum of 10 points) comprises the following items: 1) risk of bias, study quality, and study limitations, 2) precision, 3) heterogeneity, 4) directness, 5) publication bias, 6) funding bias, 7) study design, 8) effect size, and 9) dose-response. The NutriGrade score varied between 2.9 (very low meta-evidence) and 8.8 (high meta-evidence) for meta-analyses of RCTs, and it ranged between 3.1 and 8.8 for meta-analyses of cohort studies. The κ value of the ratings for each scoring item varied from 0.32 (95% CI: 0.22, 0.42) for risk of bias for cohort studies and 0.95 (95% CI: 0.91, 0.99) for study design, with a mean κ of 0.66 (95% CI: 0.53, 0.79). The ICC of the total score was 0.81 (95% CI: 0.69, 0.90). The NutriGrade scoring system showed good agreement and reliability. The initial findings regarding the performance of this newly established scoring system need further evaluation in independent analyses. PMID:28140319

  3. The Effect of SSM Grading on Reliability When Residual Items Have No Discriminating Power.

    ERIC Educational Resources Information Center

    Kane, Michael T.; Moloney, James M.

    Gilman and Ferry have shown that when the student's score on a multiple choice test is the total number of responses necessary to get all items correct, substantial increases in reliability can occur. In contrast, similar procedures giving partial credit on multiple choice items have resulted in relatively small gains in reliability. The analysis…

  4. Predicting Job Performance for the Visually Impaired: Validity of the Fine Finger Dexterity Work Task.

    ERIC Educational Resources Information Center

    Giesen, J. Martin; And Others

    The study was designed to determine the reliability and criterion validity of a psychomotor performance test (the Fine Finger Dexterity Work Task Unit) with 40 partially or totally blind adults. Reliability was established by using the test-retest method. A supervisory rating was developed and the reliability established by using the split-half…

  5. Validity and Reliability of the Academic Resilience Scale in Turkish High School

    ERIC Educational Resources Information Center

    Kapikiran, Sahin

    2012-01-01

    The present study aims to determine the validity and reliability of the academic resilience scale in Turkish high school. The participances of the study includes 378 high school students in total (192 female and 186 male). A set of analyses were conducted in order to determine the validity and reliability of the study. Firstly, both exploratory…

  6. Comparing Fit and Reliability Estimates of a Psychological Instrument Using Second-Order CFA, Bifactor, and Essentially Tau-Equivalent (Coefficient Alpha) Models via AMOS 22

    ERIC Educational Resources Information Center

    Black, Ryan A.; Yang, Yanyun; Beitra, Danette; McCaffrey, Stacey

    2015-01-01

    Estimation of composite reliability within a hierarchical modeling framework has recently become of particular interest given the growing recognition that the underlying assumptions of coefficient alpha are often untenable. Unfortunately, coefficient alpha remains the prominent estimate of reliability when estimating total scores from a scale with…

  7. Adaptation, reliability and validity testing of a Persian version of the Health Assessment Questionnaire-Disability Index in Iranian patients with rheumatoid arthritis.

    PubMed

    Nazary-Moghadam, Salman; Zeinalzadeh, Afsaneh; Salavati, Mahyar; Almasi, Simin; Negahban, Hossein

    2017-01-01

    The aim of the present study was to culturally adapt and evaluate reliability and validity of Health Assessment Questionnaire-Disability Index (HAQ-DI) in Iranian patients with rheumatoid arthritis (RA). 234 patients with RA for validation study, Eighty-six participants for reliability study. Test-retest relative reliability and internal consistency of Persian version of HAQ-DI were examined by intraclass correlation coefficient (ICC) and Cronbach's alpha, respectively. Additionally, HAQ-DI construct validity (Spearman's correlation) was examined using Persian version of Short-Form 36 Health survey (SF-36), activity and severity parameters. Persian version of HAQ-DI total score showed excellent test-retest reliability (ICC = 0.98) and internal consistency (Cronbach's alpha = 0.95). Spearman's correlations between the total PHAQ-DI score and activity and severity parameters were above 0.55. Correlation between PHAQ-DI and SF-36 Physical Health were higher as compared with SF-36 Mental Health. Persian version of HAQ-DI is a reliable and valid culturally-adapted instrument in order to measure functional limitations in Iranian people with RA. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Reliability of a Market Basket Assessment Tool (MBAT) for Use in SNAP-Ed Healthy Retail Initiatives.

    PubMed

    Misyak, Sarah A; Hedrick, Valisa E; Pudney, Ellen; Serrano, Elena L; Farris, Alisha R

    2018-05-01

    To evaluate the reliability of the Market Basket Assessment Tool (MBAT) for assessing the availability of fruits and vegetables, low-fat or nonfat dairy and eggs, lean meats, whole-grain products, and seeds, beans, and nuts in Supplemental Nutrition Assistance Program-authorized retail environments. Different trained raters used the MBAT simultaneously at 14 retail environments to measure interrater reliability. Raters returned to 12 retail environments (85.7%) 1 week later to measure test-retest reliability. Data were analyzed using paired-sample t tests and correlations. No significant differences were found for interrater reliability or test-retest reliability for individual categories (mean differences, 0.0 to 0.3 ± 0.2 points) or total score (mean difference, 0.5 ± 0.4 points and (mean differences, 0.0 to 0.3 ± 0.3 points) or total score (mean difference, 0.8 ± 0.4 points), respectively. Future steps include validation of the MBAT. A low-burden tool can facilitate evaluation of efforts to promote healthful foods in retail environments. Copyright © 2018 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  9. Evaluating the validity and reliability of the V-scale instrument (Turkish version) used to determine nurses' attitudes towards vital sign monitoring.

    PubMed

    Ertuğ, Nurcan

    2018-06-01

    The aim of this study was to determine the validity and reliability of the Turkish version of the V-scale, which measures nurses' attitudes towards vital signs monitoring in the detection of clinical deterioration. This validity and reliability study was conducted at a tertiary hospital in Ankara, Turkey, in 2016. A total of 169 ward nurses participated in the study. Exploratory factor analysis, Cronbach's alpha coefficient, and the intraclass correlation coefficient were used to determine the validity and reliability of the scale. A 5-factor, 16-item scale explained 60.823% of the total variance according to the validity analysis. Our version matched the original scale in terms of the number of items and factor structure. Cronbach's alpha coefficient of the Turkish version of the V-scale was 0.764. The test-retest reliability results were 0.855 for the overall intraclass correlation coefficient, and the t-test result was P > 0.05. The V-scale is a reliable and valid instrument to measure Turkish nurses' attitudes towards vital signs monitoring in the detection of clinical deterioration. © 2018 John Wiley & Sons Australia, Ltd.

  10. REANALYZING THE MODIFIED FERRIMAN-GALLWEY SCORE: IS THERE A SIMPLER METHOD FOR ASSESSING THE EXTENT OF HIRSUTISM?

    PubMed Central

    Cook, Heather; Brennan, Kathleen; Azziz, Ricardo

    2011-01-01

    Objective To determine whether assessing the extent of terminal hair growth in a subset of the traditional 9 areas included in the modified Ferriman-Gallwey (mFG) score can serve as a simpler predictor of total body hirsutism when compared to the full scoring system, and to determine if this new model can accurately distinguish hirsute from non-hirsute women. Design Cross-sectional analysis Setting Two tertiary care academic referral centers. Patients 1951 patients presenting for symptoms of androgen excess. Interventions History and physical examination, including mFG score. Main Outcome Measures Total body hirsutism. Results A regression model using all nine body areas indicated that the combination of upper abdomen, lower abdomen and chin was the best predictor of the total full mFG score. Using this subset of three body areas is accurate in distinguishing true hirsute from non-hirsute women when defining true hirsutism as mFG>7. Conclusion Scoring terminal hair growth only on the chin and abdomen can serve as a simple, yet reliable predictor of total body hirsutism when compared to full body scoring using the traditional mFG system. PMID:21924716

  11. Reliability program requirements for aeronautical and space system contractors

    NASA Technical Reports Server (NTRS)

    1987-01-01

    General reliability program requirements for NASA contracts involving the design, development, fabrication, test, and/or use of aeronautical and space systems including critical ground support equipment are prescribed. The reliability program requirements require (1) thorough planning and effective management of the reliability effort; (2) definition of the major reliability tasks and their place as an integral part of the design and development process; (3) planning and evaluating the reliability of the system and its elements (including effects of software interfaces) through a program of analysis, review, and test; and (4) timely status indication by formal documentation and other reporting to facilitate control of the reliability program.

  12. Validation and reliability of a Behcet's Syndrome Activity Scale in Korea.

    PubMed

    Choi, Hyo Jin; Seo, Mi Ryoung; Ryu, Hee Jung; Baek, Han Joo

    2016-01-01

    We prepared a cross-cultural adaptation of the Behcet's Syndrome Activity Scale (BSAS) and evaluated its reliability and validity in Korea. Fifty patients with Behcet's disease (BD) who attended the Rheumatology Clinic of Gachon University Gil Medical Center were included in this study. The first BSAS questionnaire was administered at each clinic visit, and the second questionnaire was completed at home within 24 hours of the visit. A Behcet's Disease Current Activity Form (BDCAF) and a Behcet's Disease Quality of Life (BDQOL) form were also given to patients. The test-retest reliability was analyzed by intraclass correlation coefficients (ICC). To assess the validity, the total BSAS score was compared with the BDCAF score, the patient/physician global assessment, and the BDQOL by Spearman rank correlation. Twelve males and 38 females were enrolled. The mean age was 48.5 years and the mean disease duration was 6.7 years. Thirty-eight patients (76.0%) returned the questionnaire by mail. For the test-retest reliability, the two assessments were significantly correlated on all 10 items of the BSAS questionnaire (p < 0.05) and the total BSAS score (ICC, 0.925; p < 0.001). The total BSAS score was statistically correlated with the BDQOL, BDCAF, and patient/physician global assessment (p < 0.01). The Korean version of BSAS is a reliable and valid instrument to measure BD activity.

  13. Sedentary Behavior in Preschoolers: How Many Days of Accelerometer Monitoring Is Needed?

    PubMed Central

    Byun, Wonwoo; Beets, Michael W.; Pate, Russell R.

    2015-01-01

    The reliability of accelerometry for measuring sedentary behavior in preschoolers has not been determined, thus we determined how many days of accelerometry monitoring are necessary to reliably estimate daily time spent in sedentary behavior in preschoolers. In total, 191 and 150 preschoolers (three to five years) wore ActiGraph accelerometers (15-s epoch) during the in-school (≥4 days) and the total-day (≥6 days) period respectively. Accelerometry data were summarized as time spent in sedentary behavior (min/h) using three different cutpoints developed for preschool-age children (<37.5, <200, and <373 counts/15 s). The intraclass correlations (ICCs) and Spearman-Brown prophecy formula were used to estimate the reliability of accelerometer for measuring sedentary behavior. Across different cutpoints, the ICCs ranged from 0.81 to 0.92 for in-school sedentary behavior, and from 0.75 to 0.81 for total-day sedentary behavior, respectively. To achieve an ICC of ≥0.8, two to four days or six to nine days of monitoring were needed for in-school sedentary behavior and total-day sedentary behavior, respectively. These findings provide important guidance for future research on sedentary behavior in preschool children using accelerometry. Understanding the reliability of accelerometry will facilitate the conduct of research designed to inform policies and practices aimed at reducing sedentary behavior in preschool children. PMID:26492261

  14. A Mixed-methods Study to Assess Interrater Reliability and Nurse Perception of the Braden Scale in a Tertiary Acute Care Setting.

    PubMed

    Ho, Chester H; Cheung, Amanda; Southern, Danielle; Ocampo, Wrechelle; Kaufman, Jaime; Hogan, David B; Baylis, Barry; Conly, John M; Stelfox, Henry T; Ghali, William A

    2016-12-01

    Research regarding the reliability of the Braden Scale and nurses' perspectives on the instrument for predicting pressure ulcer (PU) risk in acute care settings is limited. A mixed-methods study was conducted in a tertiary acute care facility to examine interrater reliability (IRR) of the Braden Scale and its subscales, and a qualitative survey using semi-structured interviews was conducted among nurses caring for patients in acute care units to gain nurse perspective regarding scale usability. Data were extracted from a previous retrospective, randomized, controlled trial involving adult patients with compromised mobility receiving care in a tertiary acute care hospital in Canada. One-way, intraclass correlation coefficients (ICCs) were calculated on item and total scores, and kappa statistics were used to determine reliability of categorizing patients on their risk. Interview results were categorized by common themes. Reliability was assessed on 64 patients, where nurses and research staff independently assessed enrolled participants at baseline and after 72 hours using the Braden Scale as it appeared on an electronic medical record. IRR for the total score was high (ICC = 0.807). The friction and shear item had the lowest reliability (ICC = 0.266). Reliability of categorizing patients' level of risk had moderate agreement (κ = 0.408). Three (3) major and 12 subthemes emerged from the 14 nurse interviews; nurses were aware of the scale's purpose but were uncertain of its effectiveness, some items were difficult to rate, and questions were raised as to whether using the scale enhanced patient care. Aspects identified by nurses to enhance usability included: 1) changes to the electronic version (incorporating the scale into daily assessment documents with readily available item descriptions), 2) additional training, and 3) easily available resource material to improve reliability and usability of scale. These findings need to be considered when using the Braden Scale in clinical practice. Further study of the value of the total Braden Scale and its subscales is warranted.

  15. Validity and Reliability of the Turkish Chronic Pain Acceptance Questionnaire

    PubMed

    Akmaz, Hazel Ekin; Uyar, Meltem; Kuzeyli Yıldırım, Yasemin; Akın Korhan, Esra

    2018-05-29

    Pain acceptance is the process of giving up the struggle with pain and learning to live a worthwhile life despite it. In assessing patients with chronic pain in Turkey, making a diagnosis and tracking the effectiveness of treatment is done with scales that have been translated into Turkish. However, there is as yet no valid and reliable scale in Turkish to assess the acceptance of pain. To validate a Turkish version of the Chronic Pain Acceptance Questionnaire developed by McCracken and colleagues. Methodological and cross sectional study. A simple randomized sampling method was used in selecting the study sample. The sample was composed of 201 patients, more than 10 times the number of items examined for validity and reliability in the study, which totaled 20. A patient identification form, the Chronic Pain Acceptance Questionnaire, and the Brief Pain Inventory were used to collect data. Data were collected by face-to-face interviews. In the validity testing, the content validity index was used to evaluate linguistic equivalence, content validity, construct validity, and expert views. In reliability testing of the scale, Cronbach’s α coefficient was calculated, and item analysis and split-test reliability methods were used. Principal component analysis and varimax rotation were used in factor analysis and to examine factor structure for construct concept validity. The item analysis established that the scale, all items, and item-total correlations were satisfactory. The mean total score of the scale was 21.78. The internal consistency coefficient was 0.94, and the correlation between the two halves of the scale was 0.89. The Chronic Pain Acceptance Questionnaire, which is intended to be used in Turkey upon confirmation of its validity and reliability, is an evaluation instrument with sufficient validity and reliability, and it can be reliably used to examine patients’ acceptance of chronic pain.

  16. Validity and Reliability of the Turkish Chronic Pain Acceptance Questionnaire

    PubMed Central

    Akmaz, Hazel Ekin; Uyar, Meltem; Kuzeyli Yıldırım, Yasemin; Akın Korhan, Esra

    2018-01-01

    Background: Pain acceptance is the process of giving up the struggle with pain and learning to live a worthwhile life despite it. In assessing patients with chronic pain in Turkey, making a diagnosis and tracking the effectiveness of treatment is done with scales that have been translated into Turkish. However, there is as yet no valid and reliable scale in Turkish to assess the acceptance of pain. Aims: To validate a Turkish version of the Chronic Pain Acceptance Questionnaire developed by McCracken and colleagues. Study Design: Methodological and cross sectional study. Methods: A simple randomized sampling method was used in selecting the study sample. The sample was composed of 201 patients, more than 10 times the number of items examined for validity and reliability in the study, which totaled 20. A patient identification form, the Chronic Pain Acceptance Questionnaire, and the Brief Pain Inventory were used to collect data. Data were collected by face-to-face interviews. In the validity testing, the content validity index was used to evaluate linguistic equivalence, content validity, construct validity, and expert views. In reliability testing of the scale, Cronbach’s α coefficient was calculated, and item analysis and split-test reliability methods were used. Principal component analysis and varimax rotation were used in factor analysis and to examine factor structure for construct concept validity. Results: The item analysis established that the scale, all items, and item-total correlations were satisfactory. The mean total score of the scale was 21.78. The internal consistency coefficient was 0.94, and the correlation between the two halves of the scale was 0.89. Conclusion: The Chronic Pain Acceptance Questionnaire, which is intended to be used in Turkey upon confirmation of its validity and reliability, is an evaluation instrument with sufficient validity and reliability, and it can be reliably used to examine patients’ acceptance of chronic pain. PMID:29843496

  17. The 747 primary flight control systems reliability and maintenance study

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The major operational characteristics of the 747 Primary Flight Control Systems (PFCS) are described. Results of reliability analysis for separate control functions are presented. The analysis makes use of a NASA computer program which calculates reliability of redundant systems. Costs for maintaining the 747 PFCS in airline service are assessed. The reliabilities and cost will provide a baseline for use in trade studies of future flight control system design.

  18. High Energy Density Capacitors for Pulsed Power Applications

    DTIC Science & Technology

    2009-07-01

    As a result of this effort, the US Military has access to capacitors that are about a third the size and half the cost of the capacitors that were...resistor in terms of shock and vibration, mounting requirements, total volume, system reliability, and cost . All of these parameters were improved...it t tipo ymer m qua y an capac or cons ruc on. Energy Density of 10,000 Shot High Efficiency Pulse Power Capacitors The primary driver was 1 5

  19. The Effect of Stages and Levels of Automation and Reliability on Workload and Performance for Remotely Piloted Aircraft Operations

    DTIC Science & Technology

    2015-03-26

    participant, it is assumed that no learning effects affected the data. Preview This chapter began with the background of RPAs and described a...for alarm- style automation systems; however, these attributes may be less relevant for other types of automation implementation. For example, with...and tactile and the speech channel was added for a total of seven channels that are being used in the DES software tool IMPRINT. This updated

  20. Fingerprinting of Materials: Technical Supplement

    NASA Technical Reports Server (NTRS)

    Workman, Gary L.

    1992-01-01

    This supplement to the Guidelines for Maintaining a Chemical Fingerprinting Program has been developed to assist NASA personnel, contractors, and sub-contractors in defining the technical aspects and basic concepts which can be used in chemical fingerprinting programs. This material is not meant to be totally inclusive to all chemical fingerprinting programs, but merely to present current concepts. Each program will be tailored to meet the needs of the individual organizations using chemical fingerprinting to improve their quality and reliability in the production of aerospace systems.

  1. Scheduling for energy and reliability management on multiprocessor real-time systems

    NASA Astrophysics Data System (ADS)

    Qi, Xuan

    Scheduling algorithms for multiprocessor real-time systems have been studied for years with many well-recognized algorithms proposed. However, it is still an evolving research area and many problems remain open due to their intrinsic complexities. With the emergence of multicore processors, it is necessary to re-investigate the scheduling problems and design/develop efficient algorithms for better system utilization, low scheduling overhead, high energy efficiency, and better system reliability. Focusing cluster schedulings with optimal global schedulers, we study the utilization bound and scheduling overhead for a class of cluster-optimal schedulers. Then, taking energy/power consumption into consideration, we developed energy-efficient scheduling algorithms for real-time systems, especially for the proliferating embedded systems with limited energy budget. As the commonly deployed energy-saving technique (e.g. dynamic voltage frequency scaling (DVFS)) will significantly affect system reliability, we study schedulers that have intelligent mechanisms to recuperate system reliability to satisfy the quality assurance requirements. Extensive simulation is conducted to evaluate the performance of the proposed algorithms on reduction of scheduling overhead, energy saving, and reliability improvement. The simulation results show that the proposed reliability-aware power management schemes could preserve the system reliability while still achieving substantial energy saving.

  2. Development and preliminary evaluation of a practice-based learning and improvement tool for assessing resident competence and guiding curriculum development.

    PubMed

    Lawrence, Renée H; Tomolo, Anne M

    2011-03-01

    Although practice-based learning and improvement (PBLI) is now recognized as a fundamental and necessary skill set, we are still in need of tools that yield specific information about gaps in knowledge and application to help nurture the development of quality improvement (QI) skills in physicians in a proficient and proactive manner. We developed a questionnaire and coding system as an assessment tool to evaluate and provide feedback regarding PBLI self-efficacy, knowledge, and application skills for residency programs and related professional requirements. Five nationally recognized QI experts/leaders reviewed and completed our questionnaire. Through an iterative process, a coding system based on identifying key variables needed for ideal responses was developed to score project proposals. The coding system comprised 14 variables related to the QI projects, and an additional 30 variables related to the core knowledge concepts related to PBLI. A total of 86 residents completed the questionnaire, and 2 raters coded their open-ended responses. Interrater reliability was assessed by percentage agreement and Cohen κ for individual variables and Lin concordance correlation for total scores for knowledge and application. Discriminative validity (t test to compare known groups) and coefficient of reproducibility as an indicator of construct validity (item difficulty hierarchy) were also assessed. Interrater reliability estimates were good (percentage of agreements, above 90%; κ, above 0.4 for most variables; concordances for total scores were R  =  .88 for knowledge and R  =  .98 for application). Despite the residents' limited range of experiences in the group with prior PBLI exposure, our tool met our goal of differentiating between the 2 groups in our preliminary analyses. Correcting for chance agreement identified some variables that are potentially problematic. Although additional evaluation is needed, our tool may prove helpful and provide detailed information about trainees' progress and the curriculum.

  3. Development and Preliminary Evaluation of a Practice-Based Learning and Improvement Tool for Assessing Resident Competence and Guiding Curriculum Development

    PubMed Central

    Lawrence, Renée H; Tomolo, Anne M

    2011-01-01

    Background Although practice-based learning and improvement (PBLI) is now recognized as a fundamental and necessary skill set, we are still in need of tools that yield specific information about gaps in knowledge and application to help nurture the development of quality improvement (QI) skills in physicians in a proficient and proactive manner. We developed a questionnaire and coding system as an assessment tool to evaluate and provide feedback regarding PBLI self-efficacy, knowledge, and application skills for residency programs and related professional requirements. Methods Five nationally recognized QI experts/leaders reviewed and completed our questionnaire. Through an iterative process, a coding system based on identifying key variables needed for ideal responses was developed to score project proposals. The coding system comprised 14 variables related to the QI projects, and an additional 30 variables related to the core knowledge concepts related to PBLI. A total of 86 residents completed the questionnaire, and 2 raters coded their open-ended responses. Interrater reliability was assessed by percentage agreement and Cohen κ for individual variables and Lin concordance correlation for total scores for knowledge and application. Discriminative validity (t test to compare known groups) and coefficient of reproducibility as an indicator of construct validity (item difficulty hierarchy) were also assessed. Results Interrater reliability estimates were good (percentage of agreements, above 90%; κ, above 0.4 for most variables; concordances for total scores were R  =  .88 for knowledge and R  =  .98 for application). Conclusion Despite the residents' limited range of experiences in the group with prior PBLI exposure, our tool met our goal of differentiating between the 2 groups in our preliminary analyses. Correcting for chance agreement identified some variables that are potentially problematic. Although additional evaluation is needed, our tool may prove helpful and provide detailed information about trainees' progress and the curriculum. PMID:22379522

  4. Scaled CMOS Reliability and Considerations for Spacecraft Systems: Bottom-Up and Top-Down Perspective

    NASA Technical Reports Server (NTRS)

    White, Mark

    2012-01-01

    New space missions will increasingly rely on more advanced technologies because of system requirements for higher performance, particularly in instruments and high-speed processing. Component-level reliability challenges with scaled CMOS in spacecraft systems from a bottom-up perspective have been presented. Fundamental Front-end and Back-end processing reliability issues with more aggressively scaled parts have been discussed. Effective thermal management from system-level to the componentlevel (top-down) is a key element in overall design of reliable systems. Thermal management in space systems must consider a wide range of issues, including thermal loading of many different components, and frequent temperature cycling of some systems. Both perspectives (top-down and bottom-up) play a large role in robust, reliable spacecraft system design.

  5. A polarized light microscopy method for accurate and reliable grading of collagen organization in cartilage repair.

    PubMed

    Changoor, A; Tran-Khanh, N; Méthot, S; Garon, M; Hurtig, M B; Shive, M S; Buschmann, M D

    2011-01-01

    Collagen organization, a feature that is critical for cartilage load bearing and durability, is not adequately assessed in cartilage repair tissue by present histological scoring systems. Our objectives were to develop a new polarized light microscopy (PLM) score for collagen organization and to test its reliability. This PLM score uses an ordinal scale of 0-5 to rate the extent that collagen network organization resembles that of young adult hyaline articular cartilage (score of 5) vs a totally disorganized tissue (score of 0). Inter-reader reliability was assessed using Intraclass Correlation Coefficients (ICC) for Agreement, calculated from scores of three trained readers who independently evaluated blinded sections obtained from normal (n=4), degraded (n=2) and repair (n=22) human cartilage biopsies. The PLM score succeeded in distinguishing normal, degraded and repair cartilages, where the latter displayed greater complexity in collagen structure. Excellent inter-reader reproducibility was found with ICCs for Agreement of 0.90 [ICC(2,1)] (lower boundary of the 95% confidence interval is 0.83) and 0.96 [ICC(2,3)] (lower boundary of the 95% confidence interval is 0.94), indicating the reliability of a single reader's scores and the mean of all three readers' scores, respectively. This PLM method offers a novel means for systematically evaluating collagen organization in repair cartilage. We propose that it be used to supplement current gold standard histological scoring systems for a more complete assessment of repair tissue quality. Copyright © 2010 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  6. Use of pharmacy delivery robots in intensive care units.

    PubMed

    Summerfield, Marc R; Seagull, F Jacob; Vaidya, Neelesh; Xiao, Yan

    2011-01-01

    The use of pharmacy delivery robots in an institution's intensive care units was evaluated. In 2003, the University of Maryland Medical Center (UMMC) began a pilot program to determine the logistic capability and functional utility of robotic technology in the delivery of medications from satellite pharmacies to patient care units. Three satellite pharmacies currently used the robotic system. Five data sources (electronic robot activation records, logs, interviews, surveys, and observations) were used to assess five key aspects of robotic delivery: robot use, reliability, timeliness, cost minimization, and acceptance. A 19-item survey using a 7-point Likert-type scale was developed to determine if pharmacy delivery robots changed nurses' perception of pharmacy service. The components measured included general satisfaction, reliability, timeliness, stat orders, services, interaction with pharmacy, and status tracking. A total of 23 pre-implementation, 96 post-implementation, and 30 two-year follow-up surveys were completed. After implementation of the robotic delivery system, time from fax to label, order preparation time, and idle time for medications to be delivered decreased, while nurses' general satisfaction with the pharmacy and opinion of the reliability of pharmacy delivery significantly increased. Robotic delivery did not influence the perceived quality of delivery service or the timeliness of orders or stat orders. Robot reliability was a major issue for the technician but not for pharmacists, who did not have as much interaction with the devices. By considering the needs of UMMC and its patients and matching them with available technology, the institution was able to improve the medication-use process and timeliness of medication departure from the pharmacy.

  7. Reliability of the Language ENvironment Analysis system (LENA™) in European French.

    PubMed

    Canault, Mélanie; Le Normand, Marie-Thérèse; Foudil, Samy; Loundon, Natalie; Thai-Van, Hung

    2016-09-01

    In this study, we examined the accuracy of the Language ENvironment Analysis (LENA) system in European French. LENA is a digital recording device with software that facilitates the collection and analysis of audio recordings from young children, providing automated measures of the speech overheard and produced by the child. Eighteen native French-speaking children, who were divided into six age groups ranging from 3 to 48 months old, were recorded about 10-16 h per day, three days a week. A total of 324 samples (six 10-min chunks of recordings) were selected and then transcribed according to the CHAT format. Simple and mixed linear models between the LENA and human adult word count (AWC) and child vocalization count (CVC) estimates were performed, to determine to what extent the automatic and the human methods agreed. Both the AWC and CVC estimates were very reliable (r = .64 and .71, respectively) for the 324 samples. When controlling the random factors of participants and recordings, 1 h was sufficient to obtain a reliable sample. It was, however, found that two age groups (7-12 months and 13-18 months) had a significant effect on the AWC data and that the second day of recording had a significant effect on the CVC data. When noise-related factors were added to the model, only a significant effect of signal-to-noise ratio was found on the AWC data. All of these findings and their clinical implications are discussed, providing strong support for the reliability of LENA in French.

  8. Reliability and concurrent validity of postural asymmetry measurement in adolescent idiopathic scoliosis

    PubMed Central

    Prowse, Ashleigh; Aslaksen, Berit; Kierkegaard, Marie; Furness, James; Gerdhem, Paul; Abbott, Allan

    2017-01-01

    AIM To investigate the reliability and concurrent validity of the Baseline® Body Level/Scoliosis meter for adolescent idiopathic scoliosis postural assessment in three anatomical planes. METHODS This is an observational reliability and concurrent validity study of adolescent referrals to the Orthopaedic department for scoliosis screening at Karolinska University Hospital, Stockholm, Sweden between March-May 2012. A total of 31 adolescents with idiopathic scoliosis (13.6 ± 0.6 years old) of mild-moderate curvatures (25° ± 12°) were consecutively recruited. Measurement of cervical, thoracic and lumbar curvatures, pelvic and shoulder tilt, and axial thoracic rotation (ATR) were performed by two trained physiotherapists in one day. The intraclass correlation coefficient (ICC) was used to determine the inter-examiner reliability (ICC2,1) and the intra-rater reliability (ICC3,3) of the Baseline® Body Level/Scoliosis meter. Spearman’s correlation analyses were used to estimate concurrent validity between the Baseline® Body Level/Scoliosis meter and Gold Standard Cobb angles from radiographs and the Orthopaedic Systems Inc. Scoliometer. RESULTS There was excellent reliability between examiners for thoracic kyphosis (ICC2,1 = 0.94), ATR (ICC2,1 = 0.92) and lumbar lordosis (ICC2,1 = 0.79). There was adequate reliability between examiners for cervical lordosis (ICC2,1 = 0.51), however poor reliability for pelvic and shoulder tilt. Both devices were reproducible in the measurement of ATR when repeated by one examiner (ICC3,3 0.98-1.00). The device had a good correlation with the Scoliometer (rho = 0.78). When compared with Cobb angle from radiographs, there was a moderate correlation for ATR (rho = 0.627). CONCLUSION The Baseline® Body Level/Scoliosis meter provides reliable transverse and sagittal cervical, thoracic and lumbar measurements and valid transverse plan measurements of mild-moderate scoliosis deformity. PMID:28144582

  9. Developing Ultra Reliable Life Support for the Moon and Mars

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.

    2009-01-01

    Recycling life support systems can achieve ultra reliability by using spares to replace failed components. The added mass for spares is approximately equal to the original system mass, provided the original system reliability is not very low. Acceptable reliability can be achieved for the space shuttle and space station by preventive maintenance and by replacing failed units, However, this maintenance and repair depends on a logistics supply chain that provides the needed spares. The Mars mission must take all the needed spares at launch. The Mars mission also must achieve ultra reliability, a very low failure rate per hour, since it requires years rather than weeks and cannot be cut short if a failure occurs. Also, the Mars mission has a much higher mass launch cost per kilogram than shuttle or station. Achieving ultra reliable space life support with acceptable mass will require a well-planned and extensive development effort. Analysis must define the reliability requirement and allocate it to subsystems and components. Technologies, components, and materials must be designed and selected for high reliability. Extensive testing is needed to ascertain very low failure rates. Systems design should segregate the failure causes in the smallest, most easily replaceable parts. The systems must be designed, produced, integrated, and tested without impairing system reliability. Maintenance and failed unit replacement should not introduce any additional probability of failure. The overall system must be tested sufficiently to identify any design errors. A program to develop ultra reliable space life support systems with acceptable mass must start soon if it is to produce timely results for the moon and Mars.

  10. Effect of using truncated versus total foot length to calculate the arch height ratio.

    PubMed

    McPoil, Thomas G; Cornwall, Mark W; Vicenzino, Bill; Teyhen, Deydre S; Molloy, Joseph M; Christie, Douglas S; Collins, Natalie

    2008-12-01

    The purpose of this study was to determine the arch height ratio in a large cohort of subjects as well as to assess the reliability and validity of the foot measurements utilized in the study. Eight hundred and fifty subjects, 393 women and 457 men, consented to participate in the study. The dorsal arch height, total foot length, and the truncated foot length were used to calculate two variations of the arch height ratio. In addition to determining within- and between-rater measurement reliability, radiographs were used to establish validity. The truncated arch height ratio can be estimated using the total foot length, unless toe deformities are present in the individual being assessed. All foot measurements had high levels of intra- and inter-rater reliability and the validity of measuring the dorsal arch height while standing with equal weight on both feet was established. This investigation provides normative values from a large cohort of healthy female and male subjects for two variations of the arch height ratio. The arch height ratio is a reliable and valid measurement that may prove useful to clinicians and researchers for the classification of foot posture.

  11. Evaluation of validity and reliability of the Persian version of the functional index of hand osteoarthritis.

    PubMed

    Kordi Yoosefinejad, Amin; Motealleh, Alireza; Babakhani, Mohammad

    2017-05-01

    The Functional index of hand osteoarthritis (FIHOA) is a commonly used patient-reported outcome questionnaire designed to measure function in patients with hand osteoarthritis. The objective of this study was to evaluate the validity and reliability of the Persian version of the FIHOA. The Persian-translated version of FIHOA was administered to 72 native Persian-speaking patients in Iran with hand osteoarthritis. Thirty-six of the patients completed the questionnaire on two occasions 1 week apart. The physical component of the SF-36 and a numerical rating scale were used to evaluate the construct validity of the Persian version of FIHOA. Internal consistency was high (Cronbach's alpha = 0.89). Test-retest reliability for the total score was excellent (weighted kappa = 0.89, 95% CI 0.79-0.94). A significant positive correlation between total FIHOA score and numerical rating scale (r = 0.70) and a significant negative correlation between total FIHOA score and the physical component scale of the SF-36 (r = -0.76) were observed. The Persian version of the FIHOA showed adequate validity and reliability to evaluate functional disability in Persian-speaking patients with hand osteoarthritis.

  12. A standard for test reliability in group research.

    PubMed

    Ellis, Jules L

    2013-03-01

    Many authors adhere to the rule that test reliabilities should be at least .70 or .80 in group research. This article introduces a new standard according to which reliabilities can be evaluated. This standard is based on the costs or time of the experiment and of administering the test. For example, if test administration costs are 7 % of the total experimental costs, the efficient value of the reliability is .93. If the actual reliability of a test is equal to this efficient reliability, the test size maximizes the statistical power of the experiment, given the costs. As a standard in experimental research, it is proposed that the reliability of the dependent variable be close to the efficient reliability. Adhering to this standard will enhance the statistical power and reduce the costs of experiments.

  13. The Application of a Residual Risk Evaluation Technique Used for Expendable Launch Vehicles

    NASA Technical Reports Server (NTRS)

    Latimer, John A.

    2009-01-01

    This presentation provides a Residual Risk Evaluation Technique (RRET) developed by Kennedy Space Center (KSC) Safety and Mission Assurance (S&MA) Launch Services Division. This technique is one of many procedures used by S&MA at KSC to evaluate residual risks for each Expendable Launch Vehicle (ELV) mission. RRET is a straight forward technique that incorporates the proven methodology of risk management, fault tree analysis, and reliability prediction. RRET derives a system reliability impact indicator from the system baseline reliability and the system residual risk reliability values. The system reliability impact indicator provides a quantitative measure of the reduction in the system baseline reliability due to the identified residual risks associated with the designated ELV mission. An example is discussed to provide insight into the application of RRET.

  14. The Female Sexual Function Index (FSFI): linguistic validation of the Italian version.

    PubMed

    Filocamo, Maria Teresa; Serati, Maurizio; Li Marzi, Vincenzo; Costantini, Elisabetta; Milanesi, Martina; Pietropaolo, Amelia; Polledro, Patrizio; Gentile, Barbara; Maruccia, Serena; Fornia, Samanta; Lauri, Irene; Alei, Rosanna; Arcangeli, Paola; Sighinolfi, Maria Chiara; Manassero, Francesca; Andretta, Elena; Palazzetti, Anna; Bertelli, Elena; Del Popolo, Giulio; Villari, Donata

    2014-02-01

    Although several new measurements for female sexual dysfunction (FSD) have recently been developed, the Female Sexual Function Index (FSFI) remains the gold standard for screening and one of the most widely used questionnaires. The Italian translation of the FSFI has been used in several studies conducted in Italy, but a linguistic validation of the Italian version does not exist. The aim of this study was to perform a linguistic validation of the Italian version of the FSFI. A multicenter cross-sectional study conducted in 14 urological and gynecological clinics, uniformly distributed over Italian territory. We performed all steps necessary to determine the reliability and the test-retest reliability of the Italian version of the FSFI. The study population was a convenience sample of 409 Italian women. The reliability of the questionnaire was calculated using Cronbach's alpha, which was considered weak, moderate, or high if its value was found less than 0.6, between 0.6 and 0.8, or equal to or greater than 0.8, respectively. The test-retest reliability was assessed for all women in the sample by calculating Pearson's concordance correlation coefficient for each domain and for the total score, both at baseline and after 15 days (r range between -1.00 to +1.00, where +1.00 indicates the strongest positive association). Cronbach's alpha coefficients for total and domain score were sufficiently high, ranging from 0.92 to 0.97 for the total sample. The test-retest procedure revealed that the concordance correlation coefficient was very high both for FSFI-I total score (Pearson's P = 0.93) and for each domain (Pearson's P always >0.92). For the first time in the literature, our study has produced a validated and reliable Italian version of the FSFI questionnaire. Consequently, the Italian FSFI can be used as a reliable tool for preliminary screening for female sexual dysfunction for Italian women. © 2013 International Society for Sexual Medicine.

  15. Reliability and validation of the Dutch Achilles tendon Total Rupture Score.

    PubMed

    Opdam, K T M; Zwiers, R; Wiegerinck, J I; Kleipool, A E B; Haverlag, R; Goslings, J C; van Dijk, C N

    2018-03-01

    Patient-reported outcome measures (PROMs) have become a cornerstone for the evaluation of the effectiveness of treatment. The Achilles tendon Total Rupture Score (ATRS) is a PROM for outcome and assessment of an Achilles tendon rupture. The aim of this study was to translate the ATRS to Dutch and evaluate its reliability and validity in the Dutch population. A forward-backward translation procedure was performed according to the guidelines of cross-cultural adaptation process. The Dutch ATRS was evaluated for reliability and validity in patients treated for a total Achilles tendon rupture from 1 January 2012 to 31 December 2014 in one teaching hospital and one academic hospital. Reliability was assessed by the intraclass correlation coefficients (ICC), Cronbach's alpha and minimal detectable change (MDC). We assessed construct validity by calculation of Spearman's rho correlation coefficient with domains of the Foot and Ankle Outcome Score (FAOS), Victorian Institute of Sports Assessment-Achilles questionnaire (VISA-A) and Numeric Rating Scale (NRS) for pain in rest and during running. The Dutch ATRS had a good test-retest reliability (ICC = 0.852) and a high internal consistency (Cronbach's alpha = 0.96). MDC was 30.2 at individual level and 3.5 at group level. Construct validity was supported by 75 % of the hypothesized correlations. The Dutch ATRS had a strong correlation with NRS for pain during running (r = -0.746) and all the five subscales of the Dutch FAOS (r = 0.724-0.867). There was a moderate correlation with the VISA-A-NL (r = 0.691) and NRS for pain in rest (r = -0.580). The Dutch ATRS shows an adequate reliability and validity and can be used in the Dutch population for measuring the outcome of treatment of a total Achilles tendon rupture and for research purposes. Diagnostic study, Level I.

  16. Total Quality Management of Information System for Quality Assessment of Pesantren Using Fuzzy-SERVQUAL

    NASA Astrophysics Data System (ADS)

    Faizah, Arbiati; Syafei, Wahyul Amien; Isnanto, R. Rizal

    2018-02-01

    This research proposed a model combining an approach of Total Quality Management (TQM) and Fuzzy method of Service Quality (SERVQUAL) to asses service quality. TQM implementation was as quality management orienting on customer's satisfaction by involving all stakeholders. SERVQUAL model was used to measure quality service based on five dimensions such as tangible, reliability, responsiveness, assurance, and empathy. Fuzzy set theory was to accommodate subjectivity and ambiguity of quality assessment. Input data consisted of indicator data and quality assessment aspect. Input data was, then, processed to be service quality assessment questionnaires of Pesantren by using Fuzzy method to get service quality score. This process consisted of some steps as follows : inputting dimension and questionnaire data to data base system, filling questionnaire through system, then, system calculated fuzzification, defuzzification, gap of quality expected and received by service receivers, and calculating each dimension rating showing quality refinement priority. Rating of each quality dimension was, then, displayed at dashboard system to enable users to see information. From system having been built, it could be known that tangible dimension had the highest gap, -0.399, thus it needs to be prioritized and gets evaluation and refinement action soon.

  17. ECG on the road: robust and unobtrusive estimation of heart rate.

    PubMed

    Wartzek, Tobias; Eilebrecht, Benjamin; Lem, Jeroen; Lindner, Hans-Joachim; Leonhardt, Steffen; Walter, Marian

    2011-11-01

    Modern automobiles include an increasing number of assistance systems to increase the driver's safety. This feasibility study investigated unobtrusive capacitive ECG measurements in an automotive environment. Electrodes integrated into the driving seat allowed to measure a reliable ECG in 86% of the drivers; when only (light) cotton clothing was worn by the drivers, this value increased to 95%. Results show that an array of sensors is needed that can adapt to the different drivers and sitting positions. Measurements while driving show that traveling on the highway does not distort the signal any more than with the car engine turned OFF, whereas driving in city traffic results in a lowered detection rate due to the driver's heavier movements. To enable robust and reliable estimation of heart rate, an algorithm is presented (based on principal component analysis) to detect and discard time intervals with artifacts. This, then, allows a reliable estimation of heart rate of up to 61% in city traffic and up to 86% on the highway: as a percentage of the total driving period with at least four consecutive QRS complexes.

  18. 75 FR 80391 - Electric Reliability Organization Interpretations of Interconnection Reliability Operations and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-22

    ... configuration to maintain system stability, acceptable voltage or power flows.\\12\\ \\12\\ In the Western... prevent system instability or cascading outages, and protect other facilities in response to transmission... nature used to address system reliability vulnerabilities to prevent system instability, cascading...

  19. Reliability of the identification of the systemic inflammatory response syndrome in critically ill infants and children.

    PubMed

    Juskewitch, Justin E; Prasad, Swati; Salas, Carlos F Santillan; Huskins, W Charles

    2012-01-01

    To assess interobserver reliability of the identification of episodes of the systemic inflammatory response syndrome in critically ill hospitalized infants and children. Retrospective, cross-sectional study of the application of the 2005 consensus definition of systemic inflammatory response syndrome in infants and children by two independent, trained reviewers using information in the electronic medical record. Eighteen-bed pediatric multidisciplinary medical/surgical pediatric intensive care unit. A randomly selected sample of children admitted consecutively to the pediatric intensive care unit between May 1 and September 30, 2009. None. Sixty infants and children were selected from a total of 343 admitted patients. Their median age was 3.9 yrs (interquartile range, 1.5-12.7), 57% were female, and 68% were Caucasian. Nineteen (32%) children were identified by both reviewers as having an episode of systemic inflammatory response syndrome (88% agreement, 95% confidence interval 78-94; κ = 0.75, 95% confidence interval 0.59-0.92). Among these 19 children, agreement between the reviewers for individual systemic inflammatory response syndrome criteria was: temperature (84%, 95% confidence interval 60-97); white blood cell count (89%, 95% confidence interval 67-99); respiratory rate (84%, 95% confidence interval 60-97); and heart rate (68%, 95% confidence interval 33-87). Episodes of systemic inflammatory response syndrome in critically ill infants and children can be identified reproducibly using the consensus definition.

  20. The new Venezuelan national control center

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beluche, C.M.

    1984-07-01

    This paper describes the actual status of the Venezuelan Electric Power System, the different operational areas involved, and finally the Interconnected System. Due to the development in the Power System, and in order to perform a more reliable and economic operation, it was established the need to implement a new supervisory system, for the Interconnected System Control Center. Also is described the system for the new control center for Oficina de Operacion de Sistemas Interconectados (OPSIS). OPSIS will monitor the Bulk Transmission Network (BTN), and will exchange information and control with the Regional Dispatch Centers through the computer network. Themore » Regional Dispatch Center (RDC) shall have the responsibility to accomplish the control order. The Bulk Transmissions System consists of that portion of the system from 800 KV to 230 KV. A total of six RDCs will be included in the system.« less

  1. Operational Experience from Solar Thermal Energy Projects

    NASA Technical Reports Server (NTRS)

    Cameron, C. P.

    1984-01-01

    Over the past few years, Sandia National Laboratories were involved in the design, construction, and operation of a number of DOE-sponsored solar thermal energy systems. Among the systems currently in operation are several industrial process heat projects and the Modular Industrial Solar Retrofit qualification test systems, all of which use parabolic troughs, and the Shenandoah Total Energy Project, which uses parabolic dishes. Operational experience has provided insight to both desirable and undesirable features of the designs of these systems. Features of these systems which are also relevant to the design of parabolic concentrator thermal electric systems are discussed. Other design features discussed are system control functions which were found to be especially convenient or effective, such as local concentrator controls, rainwash controls, and system response to changing isolation. Drive systems are also discussed with particular emphasis of the need for reliability and the usefulness of a manual drive capability.

  2. Technology developments toward 30-year-life of photovoltaic modules

    NASA Technical Reports Server (NTRS)

    Ross, R. G., Jr.

    1984-01-01

    As part of the United States National Photovoltaics Program, the Jet Propulsion Laboratory's Flat-Plate Solar Array Project (FSA) has maintained a comprehensive reliability and engineering sciences activity addressed toward understanding the reliability attributes of terrestrial flat-plate photovoltaic arrays and to deriving analysis and design tools necessary to achieve module designs with a 30-year useful life. The considerable progress to date stemming from the ongoing reliability research is discussed, and the major areas requiring continued research are highlighted. The result is an overview of the total array reliability problem and of available means of achieving high reliability at minimum cost.

  3. A Novel TRM Calculation Method by Probabilistic Concept

    NASA Astrophysics Data System (ADS)

    Audomvongseree, Kulyos; Yokoyama, Akihiko; Verma, Suresh Chand; Nakachi, Yoshiki

    In a new competitive environment, it becomes possible for the third party to access a transmission facility. From this structure, to efficiently manage the utilization of the transmission network, a new definition about Available Transfer Capability (ATC) has been proposed. According to the North American ElectricReliability Council (NERC)’s definition, ATC depends on several parameters, i. e. Total Transfer Capability (TTC), Transmission Reliability Margin (TRM), and Capacity Benefit Margin (CBM). This paper is focused on the calculation of TRM which is one of the security margin reserved for any uncertainty of system conditions. The TRM calculation by probabilistic method is proposed in this paper. Based on the modeling of load forecast error and error in transmission line limitation, various cases of transmission transfer capability and its related probabilistic nature can be calculated. By consideration of the proposed concept of risk analysis, the appropriate required amount of TRM can be obtained. The objective of this research is to provide realistic information on the actual ability of the network which may be an alternative choice for system operators to make an appropriate decision in the competitive market. The advantages of the proposed method are illustrated by application to the IEEJ-WEST10 model system.

  4. Assessment of Intraobserver and Interobserver Agreement of a New Classification System for Retrograde Periimplantitis.

    PubMed

    Shah, Rucha; Thomas, Raison; Kumar, Tarun; Mehta, Dhoom Singh

    2016-12-01

    Retrograde periimplantitis (RPI) is the inflammatory disease that affects the apical part of an osseointegrated implant while the coronal portion of the implant sustains a normal bone-to-implant interface. The aim of the current study was to assess the intraexaminer and interexaminer reliability of a proposed new classification system for RPI. After thorough electronic literature search, 56 intraoral periapical radiographs (IOPA) of implants with RPI were collected and were classified by 2 independent reviewers as per the new classification system into one of the 3-mild, moderate, and advanced-classes based on the amount of bone loss from the apex of the implant to the most coronal part as a percentage of the total implant length. The IOPAs were assessed twice by the same examiners and both were blinded to each other's observations. The intraobserver agreement ranged from 0.85 to 0.91, which falls under the category of almost perfect agreement. The interexaminer agreement was found to be 0.83, also considered as almost perfect agreement. The proposed classification shows good intraexaminer and interexaminer reliability and can be used for treatment planning and prognosis in cases of RPI.

  5. Spinning Reserve from Responsive Load

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kueck, John D; Kirby, Brendan J; Laughner, T

    2009-01-01

    As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host a spinning reserve test. The Tennessee Valley Authority (TVA) supplied real-time metering and monitoring expertise to record total hotel load during both normal operations and testing. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. The load drop was very rapid, essentially as fast as the 2 second metering couldmore » detect.« less

  6. Ion accelerator systems for high power 30 cm thruster operation

    NASA Technical Reports Server (NTRS)

    Aston, G.

    1982-01-01

    Two and three-grid accelerator systems for high power ion thruster operation were investigated. Two-grid translation tests show that over compensation of the 30 cm thruster SHAG grid set spacing the 30 cm thruster radial plasma density variation and by incorporating grid compensation only sufficient to maintain grid hole axial alignment, it is shown that beam current gains as large as 50% can be realized. Three-grid translation tests performed with a simulated 30 cm thruster discharge chamber show that substantial beamlet steering can be reliably affected by decelerator grid translation only, at net-to-total voltage ratios as low as 0.05.

  7. Toward an electrical power utility for space exploration

    NASA Technical Reports Server (NTRS)

    Bercaw, Robert W.

    1989-01-01

    Future electrical power requirements for space exploration are discussed. Megawatts of power with enough reliability for multi-year missions and with enough flexibility to adapt to needs unanticipated at design time are some of the criteria which space power systems must be able to meet. The reasons for considering the power management and distribution in the various systems, from a total mission perspective rather than simply extrapolating current spacecraft design practice, are discussed. A utility approach to electric power integrating requirements from a broad selection of current development programs, with studies in which both space and terrestrial technologies are conceptually applied to exploration mission scenarios, is described.

  8. Modify Federal Tax Code to Create Incentives for Individuals to Obtain Coverage

    PubMed Central

    McGlynn, Elizabeth A.

    2011-01-01

    Abstract This article explores how a refundable tax credit to offset the cost of health insurance premiums would affect health system performance along nine dimensions. A refundable tax credit would produce a slight gain in health as measured by life expectancy; 2.3 to 10 million people would become newly insured under this policy change. It is uncertain how the policy would affect waste or patient experience. Refundable tax credits would have no discernable effect on total health care spending, overall consumer financial risk, reliability of care, or health system capacity. Implementing refundable tax credits would be relatively easy. PMID:28083204

  9. Electronic device for endosurgical skills training (EDEST): study of reliability.

    PubMed

    Pagador, J B; Uson, J; Sánchez, M A; Moyano, J L; Moreno, J; Bustos, P; Mateos, J; Sánchez-Margallo, F M

    2011-05-01

    Minimally Invasive Surgery procedures are commonly used in many surgical practices, but surgeons need specific training models and devices due to its difficulty and complexity. In this paper, an innovative electronic device for endosurgical skills training (EDEST) is presented. A study on reliability for this device was performed. Different electronic components were used to compose this new training device. The EDEST was focused on two basic laparoscopic tasks: triangulation and coordination manoeuvres. A configuration and statistical software was developed to complement the functionality of the device. A calibration method was used to assure the proper work of the device. A total of 35 subjects (8 experts and 27 novices) were used to check the reliability of the system using the MTBF analysis. Configuration values for triangulation and coordination exercises were calculated as 0.5 s limit threshold and 800-11,000 lux range of light intensity, respectively. Zero errors in 1,050 executions (0%) for triangulation and 21 errors in 5,670 executions (0.37%) for coordination were obtained. A MTBF of 2.97 h was obtained. The results show that the reliability of the EDEST device is acceptable when used under previously defined light conditions. These results along with previous work could demonstrate that the EDEST device can help surgeons during first training stages.

  10. Measuring older adults' sedentary time: reliability, validity, and responsiveness.

    PubMed

    Gardiner, Paul A; Clark, Bronwyn K; Healy, Genevieve N; Eakin, Elizabeth G; Winkler, Elisabeth A H; Owen, Neville

    2011-11-01

    With evidence that prolonged sitting has deleterious health consequences, decreasing sedentary time is a potentially important preventive health target. High-quality measures, particularly for use with older adults, who are the most sedentary population group, are needed to evaluate the effect of sedentary behavior interventions. We examined the reliability, validity, and responsiveness to change of a self-report sedentary behavior questionnaire that assessed time spent in behaviors common among older adults: watching television, computer use, reading, socializing, transport and hobbies, and a summary measure (total sedentary time). In the context of a sedentary behavior intervention, nonworking older adults (n = 48, age = 73 ± 8 yr (mean ± SD)) completed the questionnaire on three occasions during a 2-wk period (7 d between administrations) and wore an accelerometer (ActiGraph model GT1M) for two periods of 6 d. Test-retest reliability (for the individual items and the summary measure) and validity (self-reported total sedentary time compared with accelerometer-derived sedentary time) were assessed during the 1-wk preintervention period, using Spearman (ρ) correlations and 95% confidence intervals (CI). Responsiveness to change after the intervention was assessed using the responsiveness statistic (RS). Test-retest reliability was excellent for television viewing time (ρ (95% CI) = 0.78 (0.63-0.89)), computer use (ρ (95% CI) = 0.90 (0.83-0.94)), and reading (ρ (95% CI) = 0.77 (0.62-0.86)); acceptable for hobbies (ρ (95% CI) = 0.61 (0.39-0.76)); and poor for socializing and transport (ρ < 0.45). Total sedentary time had acceptable test-retest reliability (ρ (95% CI) = 0.52 (0.27-0.70)) and validity (ρ (95% CI) = 0.30 (0.02-0.54)). Self-report total sedentary time was similarly responsive to change (RS = 0.47) as accelerometer-derived sedentary time (RS = 0.39). The summary measure of total sedentary time has good repeatability and modest validity and is sufficiently responsive to change suggesting that it is suitable for use in interventions with older adults.

  11. The Chinese version of Instrument of Professional Attitude for Student Nurses (IPASN): Assessment of reliability and validity.

    PubMed

    Xiao, Yu-Ying; Li, Ting; Xiao, Lin; Wang, Su-Wei; Wang, Si-Qi; Wang, Han-Xiao; Wang, Bei-Bei; Gao, Yu-Lin

    2017-02-01

    Professional attitude is of great importance for nursing talents in the modern society. To develop an effective educational program for student nurses in China, an appropriate instrument is required for the assessment of their professional attitude. To assess the validity and reliability of the Instrument of Professional Attitude for Student Nurses (IPASN) in Chinese version. The original version of IPASN was translated through Brislin model (translation, back translation, culture adaption and pilot study) with the authorization from the developer. A total of 681 nursing students were chosen by stratified convenience sampling to assess construct validity using exploratory factor analysis (EFA). Besides, item analysis, Cronbach's alpha coefficients, test-retest reliability were conducted to test the psychometric properties in this part. A total of 204 nursing undergraduate trainees were selected by cluster convenience sampling to confirm the structure using confirmatory factor analysis (CFA) in another time. Corrected item-total correlations, alpha if item deleted were between 0.33 and 0.69, 0.906 and 0.913, respectively, indicating no item should be deleted. Cronbach alpha value was 0.91 for the total scale and Cronbach alpha coefficient for subscales ranged from 0.67 to 0.89. Test-retest reliability estimated from intraclass correlation coefficient (ICC) was 0.74 (P<0.05). Differences in item scores between the high-score group (the first 27%) and low-score group (the last 27%) were significant (P<0.001), indicating that the item discrimination ability was good. Seven subscales (contribution to increase of scientific information load, autonomy, community service, continuous education, to promote professional development, cooperation and theory guiding practice) were identified in EFA and confirmed in CFA, and explained 65.5% of the total variance. It indicated that the Chinese version of IPASN was valid and reliable for the evaluation of nursing students' professional attitude. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. The beverage intake questionnaire: determining initial validity and reliability.

    PubMed

    Hedrick, Valisa E; Comber, Dana L; Estabrooks, Paul A; Savla, Jyoti; Davy, Brenda M

    2010-08-01

    Consuming energy-containing beverages may lead to weight gain, yet research investigating this issue is limited. An easily administered beverage intake assessment tool could facilitate research on this topic. The purpose of this cross-sectional investigation was to determine the validity and reliability of a self-administered beverage intake questionnaire (BEVQ) that estimates mean daily intake of beverages consumed across 19 beverage categories. Participants (N=105; aged 39+/-2 years) underwent assessments of height, weight, body mass index, and dietary intake using 4-day food intake records from June 2008 to June 2009. The BEVQ was completed at two additional visits (BEVQ1, BEVQ2). Urine samples were collected to objectively determine total fluid intake and encourage accurate self-reporting. Validity was assessed by comparing BEVQ1 with food intake record results; reliability was assessed by comparing BEVQ1 and BEVQ2. Analyses included descriptive statistics, bivariate correlations, paired samples t tests, and independent samples t tests. Self-reported water and total beverage intake (in grams) were not different between the BEVQ1 and food intake records (mean difference 129+/-77 g [P=0.096] and 61+/-106 g [P=0.567], respectively). Total beverage and sugar-sweetened beverage energy intake were significantly different, although mean differences were small (63 and 44 kcal, respectively). Daily consumption (in grams) of water (r=0.53), total beverages (r=0.46), and sugar-sweetened beverages (r=0.49) determined by the BEVQ1 were correlated with reported intake determined by the food intake record, as was energy from total beverages (r=0.61) and sugar-sweetened beverages (r=0.59) (all P values <0.001). Reliability was demonstrated, with correlations (P<0.001) detected between BEVQ1 and BEVQ2 results. The BEVQ is a valid, reliable, and rapid self-administered dietary assessment tool. 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  13. Computer-Aided Reliability Estimation

    NASA Technical Reports Server (NTRS)

    Bavuso, S. J.; Stiffler, J. J.; Bryant, L. A.; Petersen, P. L.

    1986-01-01

    CARE III (Computer-Aided Reliability Estimation, Third Generation) helps estimate reliability of complex, redundant, fault-tolerant systems. Program specifically designed for evaluation of fault-tolerant avionics systems. However, CARE III general enough for use in evaluation of other systems as well.

  14. Verification of Triple Modular Redundancy Insertion for Reliable and Trusted Systems

    NASA Technical Reports Server (NTRS)

    Berg, Melanie; LaBel, Kenneth

    2016-01-01

    If a system is required to be protected using triple modular redundancy (TMR), improper insertion can jeopardize the reliability and security of the system. Due to the complexity of the verification process and the complexity of digital designs, there are currently no available techniques that can provide complete and reliable confirmation of TMR insertion. We propose a method for TMR insertion verification that satisfies the process for reliable and trusted systems.

  15. Agent autonomy approach to probabilistic physics-of-failure modeling of complex dynamic systems with interacting failure mechanisms

    NASA Astrophysics Data System (ADS)

    Gromek, Katherine Emily

    A novel computational and inference framework of the physics-of-failure (PoF) reliability modeling for complex dynamic systems has been established in this research. The PoF-based reliability models are used to perform a real time simulation of system failure processes, so that the system level reliability modeling would constitute inferences from checking the status of component level reliability at any given time. The "agent autonomy" concept is applied as a solution method for the system-level probabilistic PoF-based (i.e. PPoF-based) modeling. This concept originated from artificial intelligence (AI) as a leading intelligent computational inference in modeling of multi agents systems (MAS). The concept of agent autonomy in the context of reliability modeling was first proposed by M. Azarkhail [1], where a fundamentally new idea of system representation by autonomous intelligent agents for the purpose of reliability modeling was introduced. Contribution of the current work lies in the further development of the agent anatomy concept, particularly the refined agent classification within the scope of the PoF-based system reliability modeling, new approaches to the learning and the autonomy properties of the intelligent agents, and modeling interacting failure mechanisms within the dynamic engineering system. The autonomous property of intelligent agents is defined as agent's ability to self-activate, deactivate or completely redefine their role in the analysis. This property of agents and the ability to model interacting failure mechanisms of the system elements makes the agent autonomy fundamentally different from all existing methods of probabilistic PoF-based reliability modeling. 1. Azarkhail, M., "Agent Autonomy Approach to Physics-Based Reliability Modeling of Structures and Mechanical Systems", PhD thesis, University of Maryland, College Park, 2007.

  16. Multidisciplinary System Reliability Analysis

    NASA Technical Reports Server (NTRS)

    Mahadevan, Sankaran; Han, Song; Chamis, Christos C. (Technical Monitor)

    2001-01-01

    The objective of this study is to develop a new methodology for estimating the reliability of engineering systems that encompass multiple disciplines. The methodology is formulated in the context of the NESSUS probabilistic structural analysis code, developed under the leadership of NASA Glenn Research Center. The NESSUS code has been successfully applied to the reliability estimation of a variety of structural engineering systems. This study examines whether the features of NESSUS could be used to investigate the reliability of systems in other disciplines such as heat transfer, fluid mechanics, electrical circuits etc., without considerable programming effort specific to each discipline. In this study, the mechanical equivalence between system behavior models in different disciplines are investigated to achieve this objective. A new methodology is presented for the analysis of heat transfer, fluid flow, and electrical circuit problems using the structural analysis routines within NESSUS, by utilizing the equivalence between the computational quantities in different disciplines. This technique is integrated with the fast probability integration and system reliability techniques within the NESSUS code, to successfully compute the system reliability of multidisciplinary systems. Traditional as well as progressive failure analysis methods for system reliability estimation are demonstrated, through a numerical example of a heat exchanger system involving failure modes in structural, heat transfer and fluid flow disciplines.

  17. Multi-Disciplinary System Reliability Analysis

    NASA Technical Reports Server (NTRS)

    Mahadevan, Sankaran; Han, Song

    1997-01-01

    The objective of this study is to develop a new methodology for estimating the reliability of engineering systems that encompass multiple disciplines. The methodology is formulated in the context of the NESSUS probabilistic structural analysis code developed under the leadership of NASA Lewis Research Center. The NESSUS code has been successfully applied to the reliability estimation of a variety of structural engineering systems. This study examines whether the features of NESSUS could be used to investigate the reliability of systems in other disciplines such as heat transfer, fluid mechanics, electrical circuits etc., without considerable programming effort specific to each discipline. In this study, the mechanical equivalence between system behavior models in different disciplines are investigated to achieve this objective. A new methodology is presented for the analysis of heat transfer, fluid flow, and electrical circuit problems using the structural analysis routines within NESSUS, by utilizing the equivalence between the computational quantities in different disciplines. This technique is integrated with the fast probability integration and system reliability techniques within the NESSUS code, to successfully compute the system reliability of multi-disciplinary systems. Traditional as well as progressive failure analysis methods for system reliability estimation are demonstrated, through a numerical example of a heat exchanger system involving failure modes in structural, heat transfer and fluid flow disciplines.

  18. Evaluating North American Electric Grid Reliability Using the Barabasi-Albert Network Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chassin, David P.; Posse, Christian

    2005-09-15

    The reliability of electric transmission systems is examined using a scale-free model of network topology and failure propagation. The topologies of the North American eastern and western electric grids are analyzed to estimate their reliability based on the Barabási-Albert network model. A commonly used power system reliability index is computed using a simple failure propagation model. The results are compared to the values of power system reliability indices previously obtained using other methods and they suggest that scale-free network models are usable to estimate aggregate electric grid reliability.

  19. Evaluating North American Electric Grid Reliability Using the Barabasi-Albert Network Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chassin, David P.; Posse, Christian

    2005-09-15

    The reliability of electric transmission systems is examined using a scale-free model of network topology and failure propagation. The topologies of the North American eastern and western electric grids are analyzed to estimate their reliability based on the Barabasi-Albert network model. A commonly used power system reliability index is computed using a simple failure propagation model. The results are compared to the values of power system reliability indices previously obtained using standard power engineering methods, and they suggest that scale-free network models are usable to estimate aggregate electric grid reliability.

  20. Monitoring and root cause analysis of clinical biochemistry turn around time at an academic hospital.

    PubMed

    Chauhan, Kiran P; Trivedi, Amit P; Patel, Dharmik; Gami, Bhakti; Haridas, N

    2014-10-01

    Quality can be defined as the ability of a product or service to satisfy the needs and expectations of the customer. Laboratories are more focusing on technical and analytical quality for reliability and accuracy of test results. Patients and clinicians however are interested in rapid, reliable and efficient service from laboratory. Turn around time (TAT), the timeliness with which laboratory personnel deliver test results, is one of the most noticeable signs of laboratory service and is often used as a key performance indicator of laboratory performance. This study is aims to provide clue for laboratory TAT monitoring and root cause analysis. In a 2 year period a total of 75,499 specimens of outdoor patient department were monitor, of this a total of 4,142 specimens exceeded TAT. With consistent efforts to monitor, root cause analysis and corrective measures, we are able to decreased the specimens exceeding TAT from 7-8 to 3.7 %. Though it is difficult task to monitor TAT with the help of laboratory information system, real time documentation and authentic data retrievable, along with identification of causes for delays and its remedial measures, improve laboratory TAT and thus patient satisfaction.

  1. Space Radiation Effects and Reliability Consideration for the Proposed Jupiter Europa Orbiter

    NASA Technical Reports Server (NTRS)

    Johnston, Allan

    2011-01-01

    The proposed Jupiter Europa Orbiter (JEO) mission to explore the Jovian moon Europa poses a number of challenges. The spacecraft must operate for about seven years during the transit time to the vicinity of Jupiter, and then endure unusually high radiation levels during exploration and orbiting phases. The ability to withstand usually high total dose levels is critical for the mission, along with meeting the high reliability standards for flagship NASA missions. Reliability of new microelectronic components must be sufficiently understood to meet overall mission requirements.The proposed Jupiter Europa Orbiter (JEO) mission to explore the Jovian moon Europa poses a number of challenges. The spacecraft must operate for about seven years during the transit time to the vicinity of Jupiter, and then endure unusually high radiation levels during exploration and orbiting phases. The ability to withstand usually high total dose levels is critical for the mission, along with meeting the high reliability standards for flagship NASA missions. Reliability of new microelectronic components must be sufficiently understood to meet overall mission requirements.

  2. Development of the Brazilian Portuguese version of the Achilles Tendon Total Rupture Score (ATRS BrP): a cross-cultural adaptation with reliability and construct validity evaluation.

    PubMed

    Zambelli, Roberto; Pinto, Rafael Z; Magalhães, João Murilo Brandão; Lopes, Fernando Araujo Silva; Castilho, Rodrigo Simões; Baumfeld, Daniel; Dos Santos, Thiago Ribeiro Teles; Maffulli, Nicola

    2016-01-01

    There is a need for a patient-relevant instrument to evaluate outcome after treatment in patients with a total Achilles tendon rupture. The purpose of this study was to undertake a cross-cultural adaptation of the Achilles Tendon Total Rupture Score (ATRS) into Brazilian Portuguese, determining the test-retest reliability and construct validity of the instrument. A five-step approach was used in the cross-cultural adaptation process: initial translation (two bilingual Brazilian translators), synthesis of translation, back-translation (two native English language translators), consensus version and evaluation (expert committee), and testing phase. A total of 46 patients were recruited to evaluate the test-retest reproducibility and construct validity of the Brazilian Portuguese version of the ATRS. Test-retest reproducibility was performed by assessing each participant on two separate occasions. The construct validity was determined by the correlation index between the ATRS and the Orthopedic American Foot and Ankle Society (AOFAS) questionnaires. The final version of the Brazilian Portuguese ATRS had the same number of questions as the original ATRS. For the reliability analysis, an ICC(2,1) of 0.93 (95 % CI: 0.88 to 0.96) with SEM of 1.56 points and MDC of 4.32 was observed, indicating excellent reliability. The construct validity showed excellent correlation with R = 0.76 (95 % CI: 0.52 to 0.89, P < 0.001). The ATRS was successfully cross-culturally validated into Brazilian Portuguese. This version was a reliable and valid measure of function in patients who suffered complete rupture of the Achilles Tendon.

  3. Validation of the Korean Version of the Mini-Sleep Questionnaire-Insomnia in Korean College Students.

    PubMed

    Kim, Hee-Ju

    2017-03-01

    This study aimed to evaluate the reliability and validity of the Korean version of the Mini-Sleep Questionnaire-Insomnia in Korean college students. A total of 470 students from six nursing colleges in South Korea participated in the study. The translation and linguistic validation of the Mini-Sleep Questionnaire-Insomnia was performed based on guidelines. The Pittsburgh Sleep Quality Index and the Perceived Stress Scale were used to validate the measure. Cronbach α, item-total correlation for internal consistency reliability and intraclass correlation coefficient for test-retest reliability were evaluated. Exploratory factor analysis for construct validity, Pearson's correlation with the Pittsburgh Sleep Quality Index and the Perceived Stress Scale for concurrent validity, and the receiver operating character curve for predictive validity were assessed. The 4-item Mini-Sleep Questionnaire-Insomnia had a Cronbach α of .69 and the item-total correlations were higher than .30. Cronbach α increased to .73 if the item assessing the use of sleeping pills and tranquilizers was deleted. This item had marked skewness and kurtosis issues. Factor analysis indicated unidimensionality, explaining 53.0% of the total variance. The measure showed high test-retest reliability (i.e., intraclass correlation coefficient = .84), acceptable concurrent validity (r with the Pittsburg Sleep Quality Index = .69; r with the Perceived Stress Scale = .31) and predictive validity [area under curve = .85; 95% confidence interval (0.81, 0.90)]. The Mini-Sleep Questionnaire-Insomnia showed acceptable reliability and validity. Yet, the limited distribution in sleep medications warrants further evaluations in the clinical population. Copyright © 2017. Published by Elsevier B.V.

  4. The Turkish adaptation of scale to measure patient perceptions of the quality of nursing care and related hospital services: A validity and reliability study

    PubMed Central

    Oren, Besey; Zengin, Neriman; Yildiz, Nebahat

    2016-01-01

    OBJECTIVE: This study aimed to test the validity and reliability of a version of the tool developed in Sri Lanka in 2011 to assess patient perceptions of the quality of nursing care and related hospital services created for use with Turkish patients. METHODS: This methodological study was conducted between November 2013 and November 2014 after obtaining ethical approval and organizational permission. Data was collected during discharge from 180 adult patients who were hospitalized for at least 3 days at a medical school hospital located in Istanbul. After language validation, validity and reliability analyses of the scale were conducted. Content validity, content validity index (CVI), construct validity, and exploratory factor analysis were assessed and examined, and reliability was tested using the Cronbach’s alpha coefficient and item-total correlations. RESULTS: Mean CVI was found to be 0.95, which is above expected value. Exploratory factor analysis revealed 4 factors with eigenvalues above 1, which explained 82.4% of total variance in the Turkish version of the tool to measure patient perceptions of nursing care and other hospital services. Factor loading for each item was ≥.40. Cronbach’s alpha coefficient of sub-dimensions and total scale were found to be 0.84-0.98 and 0.98, respectively. Item-total correlations ranged from 0.56 to 0.83 for the entire group, which was above expected values. CONCLUSION: The Turkish version of the scale to assess patient perceptions of the quality of nursing care and related hospital services, which comprised 4 sub-dimensions and 36 items, was found to be valid and reliable for use with the Turkish population. PMID:28275750

  5. The Turkish adaptation of scale to measure patient perceptions of the quality of nursing care and related hospital services: A validity and reliability study.

    PubMed

    Oren, Besey; Zengin, Neriman; Yildiz, Nebahat

    2016-01-01

    This study aimed to test the validity and reliability of a version of the tool developed in Sri Lanka in 2011 to assess patient perceptions of the quality of nursing care and related hospital services created for use with Turkish patients. This methodological study was conducted between November 2013 and November 2014 after obtaining ethical approval and organizational permission. Data was collected during discharge from 180 adult patients who were hospitalized for at least 3 days at a medical school hospital located in Istanbul. After language validation, validity and reliability analyses of the scale were conducted. Content validity, content validity index (CVI), construct validity, and exploratory factor analysis were assessed and examined, and reliability was tested using the Cronbach's alpha coefficient and item-total correlations. Mean CVI was found to be 0.95, which is above expected value. Exploratory factor analysis revealed 4 factors with eigenvalues above 1, which explained 82.4% of total variance in the Turkish version of the tool to measure patient perceptions of nursing care and other hospital services. Factor loading for each item was ≥.40. Cronbach's alpha coefficient of sub-dimensions and total scale were found to be 0.84-0.98 and 0.98, respectively. Item-total correlations ranged from 0.56 to 0.83 for the entire group, which was above expected values. The Turkish version of the scale to assess patient perceptions of the quality of nursing care and related hospital services, which comprised 4 sub-dimensions and 36 items, was found to be valid and reliable for use with the Turkish population.

  6. The MG Composite

    PubMed Central

    Burns, Ted M.; Conaway, Mark; Sanders, Donald B.

    2010-01-01

    Objective: To study the concurrent and construct validity and test-retest reliability in the practice setting of an outcome measure for myasthenia gravis (MG). Methods: Eleven centers participated in the validation study of the Myasthenia Gravis Composite (MGC) scale. Patients with MG were evaluated at 2 consecutive visits. Concurrent and construct validities of the MGC were assessed by evaluating MGC scores in the context of other MG-specific outcome measures. We used numerous potential indicators of clinical improvement to assess the sensitivity and specificity of the MGC for detecting clinical improvement. Test-retest reliability was performed on patients at the University of Virginia. Results: A total of 175 patients with MG were enrolled at 11 sites from July 1, 2008, to January 31, 2009. A total of 151 patients were seen in follow-up. Total MGC scores showed excellent concurrent validity with other MG-specific scales. Analyses of sensitivities and specificities of the MGC revealed that a 3-point improvement in total MGC score was optimal for signifying clinical improvement. A 3-point improvement in the MGC also appears to represent a meaningful improvement to most patients, as indicated by improved 15-item myasthenia gravis quality of life scale (MG-QOL15) scores. The psychometric properties were no better for an individualized subscore made up of the 2 functional domains that the patient identified as most important to treat. The test-retest reliability coefficient of the MGC was 98%, with a lower 95% confidence interval of 97%, indicating excellent test-retest reliability. Conclusions: The Myasthenia Gravis Composite is a reliable and valid instrument for measuring clinical status of patients with myasthenia gravis in the practice setting and in clinical trials. PMID:20439845

  7. Hawaii electric system reliability.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silva Monroy, Cesar Augusto; Loose, Verne William

    2012-09-01

    This report addresses Hawaii electric system reliability issues; greater emphasis is placed on short-term reliability but resource adequacy is reviewed in reference to electric consumers' views of reliability %E2%80%9Cworth%E2%80%9D and the reserve capacity required to deliver that value. The report begins with a description of the Hawaii electric system to the extent permitted by publicly available data. Electrical engineering literature in the area of electric reliability is researched and briefly reviewed. North American Electric Reliability Corporation standards and measures for generation and transmission are reviewed and identified as to their appropriateness for various portions of the electric grid and formore » application in Hawaii. Analysis of frequency data supplied by the State of Hawaii Public Utilities Commission is presented together with comparison and contrast of performance of each of the systems for two years, 2010 and 2011. Literature tracing the development of reliability economics is reviewed and referenced. A method is explained for integrating system cost with outage cost to determine the optimal resource adequacy given customers' views of the value contributed by reliable electric supply. The report concludes with findings and recommendations for reliability in the State of Hawaii.« less

  8. Hawaii Electric System Reliability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loose, Verne William; Silva Monroy, Cesar Augusto

    2012-08-01

    This report addresses Hawaii electric system reliability issues; greater emphasis is placed on short-term reliability but resource adequacy is reviewed in reference to electric consumers’ views of reliability “worth” and the reserve capacity required to deliver that value. The report begins with a description of the Hawaii electric system to the extent permitted by publicly available data. Electrical engineering literature in the area of electric reliability is researched and briefly reviewed. North American Electric Reliability Corporation standards and measures for generation and transmission are reviewed and identified as to their appropriateness for various portions of the electric grid and formore » application in Hawaii. Analysis of frequency data supplied by the State of Hawaii Public Utilities Commission is presented together with comparison and contrast of performance of each of the systems for two years, 2010 and 2011. Literature tracing the development of reliability economics is reviewed and referenced. A method is explained for integrating system cost with outage cost to determine the optimal resource adequacy given customers’ views of the value contributed by reliable electric supply. The report concludes with findings and recommendations for reliability in the State of Hawaii.« less

  9. Mathematical modeling and fuzzy availability analysis for serial processes in the crystallization system of a sugar plant

    NASA Astrophysics Data System (ADS)

    Aggarwal, Anil Kr.; Kumar, Sanjeev; Singh, Vikram

    2017-03-01

    The binary states, i.e., success or failed state assumptions used in conventional reliability are inappropriate for reliability analysis of complex industrial systems due to lack of sufficient probabilistic information. For large complex systems, the uncertainty of each individual parameter enhances the uncertainty of the system reliability. In this paper, the concept of fuzzy reliability has been used for reliability analysis of the system, and the effect of coverage factor, failure and repair rates of subsystems on fuzzy availability for fault-tolerant crystallization system of sugar plant is analyzed. Mathematical modeling of the system is carried out using the mnemonic rule to derive Chapman-Kolmogorov differential equations. These governing differential equations are solved with Runge-Kutta fourth-order method.

  10. Soft error evaluation and vulnerability analysis in Xilinx Zynq-7010 system-on chip

    NASA Astrophysics Data System (ADS)

    Du, Xuecheng; He, Chaohui; Liu, Shuhuan; Zhang, Yao; Li, Yonghong; Xiong, Ceng; Tan, Pengkang

    2016-09-01

    Radiation-induced soft errors are an increasingly important threat to the reliability of modern electronic systems. In order to evaluate system-on chip's reliability and soft error, the fault tree analysis method was used in this work. The system fault tree was constructed based on Xilinx Zynq-7010 All Programmable SoC. Moreover, the soft error rates of different components in Zynq-7010 SoC were tested by americium-241 alpha radiation source. Furthermore, some parameters that used to evaluate the system's reliability and safety were calculated using Isograph Reliability Workbench 11.0, such as failure rate, unavailability and mean time to failure (MTTF). According to fault tree analysis for system-on chip, the critical blocks and system reliability were evaluated through the qualitative and quantitative analysis.

  11. The Reliability and Precision of Total Scores and IRT Estimates as a Function of Polytomous IRT Parameters and Latent Trait Distribution

    ERIC Educational Resources Information Center

    Culpepper, Steven Andrew

    2013-01-01

    A classic topic in the fields of psychometrics and measurement has been the impact of the number of scale categories on test score reliability. This study builds on previous research by further articulating the relationship between item response theory (IRT) and classical test theory (CTT). Equations are presented for comparing the reliability and…

  12. A Reliability Improvement Program Planning Report for the SNAP 10A Space Nuclear Power Unit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coombs, M. G.; Smith, C. K.; Wilson, L. A.

    1961-03-14

    The estimated achieved reliability of SNAP 10A space nuclear power units will be relatively low at the timeof the first SNAPSHOT flight test in April 1963 and the existing R&D program does not provide a significant reliabiity growth thereafter. The total costs of an 8-satellite network using SNAP 10A units over a 5-year period has been approximated for the case where the total cost of a single satellite launched is 8 million dollars.

  13. The reliability-quality relationship for quality systems and quality risk management.

    PubMed

    Claycamp, H Gregg; Rahaman, Faiad; Urban, Jason M

    2012-01-01

    Engineering reliability typically refers to the probability that a system, or any of its components, will perform a required function for a stated period of time and under specified operating conditions. As such, reliability is inextricably linked with time-dependent quality concepts, such as maintaining a state of control and predicting the chances of losses from failures for quality risk management. Two popular current good manufacturing practice (cGMP) and quality risk management tools, failure mode and effects analysis (FMEA) and root cause analysis (RCA) are examples of engineering reliability evaluations that link reliability with quality and risk. Current concepts in pharmaceutical quality and quality management systems call for more predictive systems for maintaining quality; yet, the current pharmaceutical manufacturing literature and guidelines are curiously silent on engineering quality. This commentary discusses the meaning of engineering reliability while linking the concept to quality systems and quality risk management. The essay also discusses the difference between engineering reliability and statistical (assay) reliability. The assurance of quality in a pharmaceutical product is no longer measured only "after the fact" of manufacturing. Rather, concepts of quality systems and quality risk management call for designing quality assurance into all stages of the pharmaceutical product life cycle. Interestingly, most assays for quality are essentially static and inform product quality over the life cycle only by being repeated over time. Engineering process reliability is the fundamental concept that is meant to anticipate quality failures over the life cycle of the product. Reliability is a well-developed theory and practice for other types of manufactured products and manufacturing processes. Thus, it is well known to be an appropriate index of manufactured product quality. This essay discusses the meaning of reliability and its linkages with quality systems and quality risk management.

  14. Space Transportation System Availability Requirement and Its Influencing Attributes Relationships

    NASA Technical Reports Server (NTRS)

    Rhodes, Russell E.; Adams, Timothy C.; McCleskey, Carey M.

    2008-01-01

    It is important that engineering and management accept the need for an availability requirement that is derived with its influencing attributes. It is the intent of this paper to provide the visibility of relationships of these major attribute drivers (variables) to each other and the resultant system inherent availability. Also important to provide bounds of the variables providing engineering the insight required to control the system's engineering solution, e.g., these influencing attributes become design requirements also. These variables will drive the need to provide integration of similar discipline functions or technology selection to allow control of the total parts count. The relationship of selecting a reliability requirement will place a constraint on parts count to achieve a given availability requirement or if allowed to increase the parts count will drive the system reliability requirement higher. They also provide the understanding for the relationship of mean repair time (or mean down time) to maintainability, e.g., accessibility for repair, and both the mean time between failure, e.g., reliability of hardware and availability. The concerns and importance of achieving a strong availability requirement is driven by the need for affordability, the choice of using the two launch solution for the single space application, or the need to control the spare parts count needed to support the long stay in either orbit or on the surface of the moon. Understanding the requirements before starting the architectural design concept will avoid considerable time and money required to iterate the design to meet the redesign and assessment process required to achieve the results required of the customer's space transportation system. In fact the impact to the schedule to being able to deliver the system that meets the customer's needs, goals, and objectives may cause the customer to compromise his desired operational goal and objectives resulting in considerable increased life cycle cost of the fielded space transportation system.

  15. Space Transportation System Availability Requirements and Its Influencing Attributes Relationships

    NASA Technical Reports Server (NTRS)

    Rhodes, Russell E.; Adams, Timothy C.; McCleskey, Carey M.

    2008-01-01

    It is important that engineering and management accept the need for an availability requirement that is derived with its influencing attributes. It is the intent of this paper to provide the visibility of relationships of these major attribute drivers (variables) to each other and the resultant system inherent availability. Also important to provide bounds of the variables providing engineering the insight required to control the system's engineering solution, e.g., these influencing attributes become design requirements also. These variables will drive the need to provide integration of similar discipline functions or technology selection to allow control of the total parts count. The relationship of selecting a reliability requirement will place a constraint on parts count to achieve a given availability requirement or if allowed to increase the parts count will drive the system reliability requirement higher. They also provide the understanding for the relationship of mean repair time (or mean down time) to maintainability, e.g., accessibility for repair, and both the mean time between failure, e.g., reliability of hardware and availability. The concerns and importance of achieving a strong availability requirement is driven by the need for affordability, the choice of using the two launch solution for the single space application, or the need to control the spare parts count needed to support the long stay in either orbit or on the surface of the moon. Understanding the requirements before starting the architectural design concept will avoid considerable time and money required to iterate the design to meet the redesign and assessment process required to achieve the results required of the customer's space transportation system. In fact the impact to the schedule to being able to deliver the system that meets the customer's needs, goals, and objectives may cause the customer to compromise his desired operational goal and objectives resulting in considerable increased life cycle cost of the fielded space transportation system.

  16. Measurement of Total and Free Urinary Phenol and Paraben Concentrations over the Course of Pregnancy: Assessing Reliability and Contamination of Specimens in the Norwegian Mother and Child Cohort Study

    PubMed Central

    Longnecker, Matthew P.; Aase, Heidi; Eggesbø, Merete; Zeiner, Pål; Reichborn-Kjennerud, Ted; Knudsen, Gun P.; Bertelsen, Randi J.; Ye, Xiaoyun; Calafat, Antonia M.; Engel, Stephanie M.

    2015-01-01

    Background Exposures to environmental phenols and parabens may be harmful, especially in utero. Prior studies have demonstrated high within-person variability of urinary concentrations across pregnancy. Objectives We sought to measure phenol and paraben biomarker concentrations for the Norwegian Mother and Child Cohort (MoBa) study, assess within-person variability, and investigate any possible external phenol or paraben contamination of specimens. Methods We collected three spot urine samples at approximately 17, 23, and 29 weeks gestation in a hospital setting and added a preservative containing ethyl paraben. We measured urinary concentrations and within-person variability for phenols and parabens in a MoBa sample (n = 45), including a subgroup of 15 participants previously randomly selected for a bisphenol A (BPA) exposure study who had unusually high total BPA concentrations. Additionally, we compared reliability results for total, conjugated, and free concentrations of phenolic compounds. Results We detected total and free BPA, butyl paraben, propyl paraben, and methyl paraben in 100% of samples, total benzophenone-3 in 95% of samples, and infrequently detected free benzophenone-3 and total and free 2,4-dichlorophenol and 2,5-dichlorophenol. Intraclass correlation coefficients (ICCs) for total, conjugated, and free concentrations ranged from relatively low for BPA to moderate for propyl paraben. ICCs were generally similar overall and by subgroup. Conclusions Using conjugated concentrations improved reliability estimates only for BPA. Measuring total and free concentrations, an approach that may be useful for future studies, allowed us to identify likely BPA and butyl paraben contamination of archived MoBa urine specimens. Citation Guidry VT, Longnecker MP, Aase H, Eggesbø M, Zeiner P, Reichborn-Kjennerud T, Knudsen GP, Bertelsen RJ, Ye X, Calafat AM, Engel SM. 2015. Measurement of total and free urinary phenol and paraben concentrations over the course of pregnancy: assessing reliability and contamination of specimens in the Norwegian Mother and Child Cohort Study. Environ Health Perspect 123:705–711; http://dx.doi.org/10.1289/ehp.1408325 PMID:25782115

  17. X-33/RLV System Health Management/Vehicle Health Management

    NASA Technical Reports Server (NTRS)

    Mouyos, William; Wangu, Srimal

    1998-01-01

    To reduce operations costs, Reusable Launch Vehicles (RLVS) must include highly reliable robust subsystems which are designed for simple repair access with a simplified servicing infrastructure, and which incorporate expedited decision-making about faults and anomalies. A key component for the Single Stage To Orbit (SSTO) RLV system used to meet these objectives is System Health Management (SHM). SHM incorporates Vehicle Health Management (VHM), ground processing associated with the vehicle fleet (GVHM), and Ground Infrastructure Health Management (GIHM). The primary objective of SHM is to provide an automated and paperless health decision, maintenance, and logistics system. Sanders, a Lockheed Martin Company, is leading the design, development, and integration of the SHM system for RLV and for X-33 (a sub-scale, sub-orbit Advanced Technology Demonstrator). Many critical technologies are necessary to make SHM (and more specifically VHM) practical, reliable, and cost effective. This paper will present the X-33 SHM design which forms the baseline for the RLV SHM, and it will discuss applications of advanced technologies to future RLVs. In addition, this paper will describe a Virtual Design Environment (VDE) which is being developed for RLV. This VDE will allow for system design engineering, as well as program management teams, to accurately and efficiently evaluate system designs, analyze the behavior of current systems, and predict the feasibility of making smooth and cost-efficient transitions from older technologies to newer ones. The RLV SHM design methodology will reduce program costs, decrease total program life-cycle time, and ultimately increase mission success.

  18. A Turkish version of myocardial infarction dimensional assessment scale (TR-MIDAS): reliability-validity assesment.

    PubMed

    Uysal, Hilal; Ozcan, Şeyda

    2011-06-01

    Many new measuring devices have been developed so that broader psychometric measurements in the coronary artery disease, disease-specific health status measurements, and identification of the broader quality of life can be performed in the recent years. The study was intended to determine whether, and to what extent, MIDAS is a valid and reliable measurement to the patients suffering from myocardial infarction for the first time in Turkey. The research was conducted with the patients hospitalized and treated with myocardial infarction in the cardiology departments of 2 hospitals in Istanbul, Turkey, between 2007 and 2008. Psychometric evaluations of TR-MIDAS were used for validity studies; language validity, content validity, construct validity were examined. For reliability studies; the tool's internal consistency reliability, Cronbach's alpha reliability coefficient, and test-retest reliability were completed. The instrument's content validity index was determined to be "0.95". Principal component analysis revealed six factors with an eigenvalue >1.5. Cronbach's alpha was found to be 0.89 for total scale which was an acceptable value. The total's test-retest reliability was 0.51 (p<0.01). Data obtained at the end of the study supports that Turkish Myocardial Infarction Dimensional Assessment Scale is a valid and reliable instrument as a disease-specific scale to assess the patients' quality of life suffering from myocardial infarction in Turkey. Copyright © 2010 European Society of Cardiology. Published by Elsevier B.V. All rights reserved.

  19. Study on Distribution Reliability with Parallel and On-site Distributed Generation Considering Protection Miscoordination and Tie Line

    NASA Astrophysics Data System (ADS)

    Chaitusaney, Surachai; Yokoyama, Akihiko

    In distribution system, Distributed Generation (DG) is expected to improve the system reliability as its backup generation. However, DG contribution in fault current may cause the loss of the existing protection coordination, e.g. recloser-fuse coordination and breaker-breaker coordination. This problem can drastically deteriorate the system reliability, and it is more serious and complicated when there are several DG sources in the system. Hence, the above conflict in reliability aspect unavoidably needs a detailed investigation before the installation or enhancement of DG is done. The model of composite DG fault current is proposed to find the threshold beyond which existing protection coordination is lost. Cases of protection miscoordination are described, together with their consequences. Since a distribution system may be tied with another system, the issues of tie line and on-site DG are integrated into this study. Reliability indices are evaluated and compared in the distribution reliability test system RBTS Bus 2.

  20. A Passive System Reliability Analysis for a Station Blackout

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brunett, Acacia; Bucknor, Matthew; Grabaskas, David

    2015-05-03

    The latest iterations of advanced reactor designs have included increased reliance on passive safety systems to maintain plant integrity during unplanned sequences. While these systems are advantageous in reducing the reliance on human intervention and availability of power, the phenomenological foundations on which these systems are built require a novel approach to a reliability assessment. Passive systems possess the unique ability to fail functionally without failing physically, a result of their explicit dependency on existing boundary conditions that drive their operating mode and capacity. Argonne National Laboratory is performing ongoing analyses that demonstrate various methodologies for the characterization of passivemore » system reliability within a probabilistic framework. Two reliability analysis techniques are utilized in this work. The first approach, the Reliability Method for Passive Systems, provides a mechanistic technique employing deterministic models and conventional static event trees. The second approach, a simulation-based technique, utilizes discrete dynamic event trees to treat time- dependent phenomena during scenario evolution. For this demonstration analysis, both reliability assessment techniques are used to analyze an extended station blackout in a pool-type sodium fast reactor (SFR) coupled with a reactor cavity cooling system (RCCS). This work demonstrates the entire process of a passive system reliability analysis, including identification of important parameters and failure metrics, treatment of uncertainties and analysis of results.« less

  1. A high performance system for molecular dynamics simulation of biomolecules using a special-purpose computer.

    PubMed

    Komeiji, Y; Yokoyama, H; Uebayasi, M; Taiji, M; Fukushige, T; Sugimoto, D; Takata, R; Shimizu, A; Itsukashi, K

    1996-01-01

    GRAPE (GRavity PipE) processors are special purpose computers for simulation of classical particles. The performance of MD-GRAPE, one of the GRAPEs developed for molecular dynamics, was investigated. The effective speed of MD-GRAPE was equivalent to approximately 6 Gflops. The precision of MD-GRAPE was good judging from the acceptable fluctuation of the total energy. Then a software named PEACH (Program for Energetic Analysis of bioCHemical molecules) was developed for molecular dynamics of biomolecules in combination with MD-GRAPE. Molecular dynamics simulation was performed for several protein-solvent systems with different sizes. Simulation of the largest system investigated (27,000 atoms) took only 5 sec/step. Thus, the PEACH-GRAPE system is expected to be useful in accurate and reliable simulation of large biomolecules.

  2. Performance Analysis on Carrier Phase-Based Tightly-Coupled GPS/BDS/INS Integration in GNSS Degraded and Denied Environments

    PubMed Central

    Han, Houzeng; Wang, Jian; Wang, Jinling; Tan, Xinglong

    2015-01-01

    The integration of Global Navigation Satellite Systems (GNSS) carrier phases with Inertial Navigation System (INS) measurements is essential to provide accurate and continuous position, velocity and attitude information, however it is necessary to fix ambiguities rapidly and reliably to obtain high accuracy navigation solutions. In this paper, we present the notion of combining the Global Positioning System (GPS), the BeiDou Navigation Satellite System (BDS) and low-cost micro-electro-mechanical sensors (MEMS) inertial systems for reliable navigation. An adaptive multipath factor-based tightly-coupled (TC) GPS/BDS/INS integration algorithm is presented and the overall performance of the integrated system is illustrated. A twenty seven states TC GPS/BDS/INS model is adopted with an extended Kalman filter (EKF), which is carried out by directly fusing ambiguity fixed double-difference (DD) carrier phase measurements with the INS predicted pseudoranges to estimate the error states. The INS-aided integer ambiguity resolution (AR) strategy is developed by using a dynamic model, a two-step estimation procedure is applied with adaptively estimated covariance matrix to further improve the AR performance. A field vehicular test was carried out to demonstrate the positioning performance of the combined system. The results show the TC GPS/BDS/INS system significantly improves the single-epoch AR reliability as compared to that of GPS/BDS-only or single satellite navigation system integrated strategy, especially for high cut-off elevations. The AR performance is also significantly improved for the combined system with adaptive covariance matrix in the presence of low elevation multipath related to the GNSS-only case. A total of fifteen simulated outage tests also show that the time to relock of the GPS/BDS signals is shortened, which improves the system availability. The results also indicate that TC integration system achieves a few centimeters accuracy in positioning based on the comparison analysis and covariance analysis, even in harsh environments (e.g., in urban canyons), thus we can see the advantage of positioning at high cut-off elevations that the combined GPS/BDS brings. PMID:25875191

  3. Performance analysis on carrier phase-based tightly-coupled GPS/BDS/INS integration in GNSS degraded and denied environments.

    PubMed

    Han, Houzeng; Wang, Jian; Wang, Jinling; Tan, Xinglong

    2015-04-14

    The integration of Global Navigation Satellite Systems (GNSS) carrier phases with Inertial Navigation System (INS) measurements is essential to provide accurate and continuous position, velocity and attitude information, however it is necessary to fix ambiguities rapidly and reliably to obtain high accuracy navigation solutions. In this paper, we present the notion of combining the Global Positioning System (GPS), the BeiDou Navigation Satellite System (BDS) and low-cost micro-electro-mechanical sensors (MEMS) inertial systems for reliable navigation. An adaptive multipath factor-based tightly-coupled (TC) GPS/BDS/INS integration algorithm is presented and the overall performance of the integrated system is illustrated. A twenty seven states TC GPS/BDS/INS model is adopted with an extended Kalman filter (EKF), which is carried out by directly fusing ambiguity fixed double-difference (DD) carrier phase measurements with the INS predicted pseudoranges to estimate the error states. The INS-aided integer ambiguity resolution (AR) strategy is developed by using a dynamic model, a two-step estimation procedure is applied with adaptively estimated covariance matrix to further improve the AR performance. A field vehicular test was carried out to demonstrate the positioning performance of the combined system. The results show the TC GPS/BDS/INS system significantly improves the single-epoch AR reliability as compared to that of GPS/BDS-only or single satellite navigation system integrated strategy, especially for high cut-off elevations. The AR performance is also significantly improved for the combined system with adaptive covariance matrix in the presence of low elevation multipath related to the GNSS-only case. A total of fifteen simulated outage tests also show that the time to relock of the GPS/BDS signals is shortened, which improves the system availability. The results also indicate that TC integration system achieves a few centimeters accuracy in positioning based on the comparison analysis and covariance analysis, even in harsh environments (e.g., in urban canyons), thus we can see the advantage of positioning at high cut-off elevations that the combined GPS/BDS brings.

  4. The critical distance in laser-induced plasmas: an operative definition

    NASA Astrophysics Data System (ADS)

    Delle Side, D.; Giuffreda, E.; Nassisi, V.

    2016-05-01

    We propose a method to estimate a precise value for the critical distance Lcr after which three-body recombination stops to produce charge losses in an expanding laser-induced plasma. We show in particular that the total charge collected has a ``reversed sigmoid'' shape as a function of the target-to-detector distance. Fitting the total charge data with a logistic related function, we could consider as Lcr the intercept of the tangent to this curve in its inflection point. Furthermore, this value scales well with theoretical predictions. From the application point of view, this could be of great practical interest, since it provide a reliable way to precisely determine the geometry of the extraction system in Laser Ion Sources.

  5. 40 CFR 75.42 - Reliability criteria.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Reliability criteria. 75.42 Section 75...) CONTINUOUS EMISSION MONITORING Alternative Monitoring Systems § 75.42 Reliability criteria. To demonstrate reliability equal to or better than the continuous emission monitoring system, the owner or operator shall...

  6. Integrating Reliability Analysis with a Performance Tool

    NASA Technical Reports Server (NTRS)

    Nicol, David M.; Palumbo, Daniel L.; Ulrey, Michael

    1995-01-01

    A large number of commercial simulation tools support performance oriented studies of complex computer and communication systems. Reliability of these systems, when desired, must be obtained by remodeling the system in a different tool. This has obvious drawbacks: (1) substantial extra effort is required to create the reliability model; (2) through modeling error the reliability model may not reflect precisely the same system as the performance model; (3) as the performance model evolves one must continuously reevaluate the validity of assumptions made in that model. In this paper we describe an approach, and a tool that implements this approach, for integrating a reliability analysis engine into a production quality simulation based performance modeling tool, and for modeling within such an integrated tool. The integrated tool allows one to use the same modeling formalisms to conduct both performance and reliability studies. We describe how the reliability analysis engine is integrated into the performance tool, describe the extensions made to the performance tool to support the reliability analysis, and consider the tool's performance.

  7. The reliability analysis of a separated, dual fail operational redundant strapdown IMU. [inertial measurement unit

    NASA Technical Reports Server (NTRS)

    Motyka, P.

    1983-01-01

    A methodology for quantitatively analyzing the reliability of redundant avionics systems, in general, and the dual, separated Redundant Strapdown Inertial Measurement Unit (RSDIMU), in particular, is presented. The RSDIMU is described and a candidate failure detection and isolation system presented. A Markov reliability model is employed. The operational states of the system are defined and the single-step state transition diagrams discussed. Graphical results, showing the impact of major system parameters on the reliability of the RSDIMU system, are presented and discussed.

  8. Reliability issues of free-space communications systems and networks

    NASA Astrophysics Data System (ADS)

    Willebrand, Heinz A.

    2003-04-01

    Free space optics (FSO) is a high-speed point-to-point connectivity solution traditionally used in the enterprise campus networking market for building-to-building LAN connectivity. However, more recently some wire line and wireless carriers started to deploy FSO systems in their networks. The requirements on FSO system reliability, meaing both system availability and component reliability, are far more stringent in the carrier market when compared to the requirements in the enterprise market segment. This paper tries to outline some of the aspects that are important to ensure carrier class system reliability.

  9. Advanced reliability modeling of fault-tolerant computer-based systems

    NASA Technical Reports Server (NTRS)

    Bavuso, S. J.

    1982-01-01

    Two methodologies for the reliability assessment of fault tolerant digital computer based systems are discussed. The computer-aided reliability estimation 3 (CARE 3) and gate logic software simulation (GLOSS) are assessment technologies that were developed to mitigate a serious weakness in the design and evaluation process of ultrareliable digital systems. The weak link is based on the unavailability of a sufficiently powerful modeling technique for comparing the stochastic attributes of one system against others. Some of the more interesting attributes are reliability, system survival, safety, and mission success.

  10. Methodology for Software Reliability Prediction. Volume 1.

    DTIC Science & Technology

    1987-11-01

    SPACECRAFT 0 MANNED SPACECRAFT B ATCH SYSTEM AIRBORNE AVIONICS 0 UNMANNED EVENT C014TROL a REAL TIME CLOSED 0 UNMANNED SPACECRAFT LOOP OPERATINS SPACECRAFT...software reliability. A Software Reliability Measurement Framework was established which spans the life cycle of a software system and includes the...specification, prediction, estimation, and assessment of software reliability. Data from 59 systems , representing over 5 million lines of code, were

  11. Pocket Handbook on Reliability

    DTIC Science & Technology

    1975-09-01

    exponencial distributions Weibull distribution, -xtimating reliability, confidence intervals, relia- bility growth, 0. P- curves, Bayesian analysis. 20 A S...introduction for those not familiar with reliability and a good refresher for those who are currently working in the area. LEWIS NERI, CHIEF...includes one or both of the following objectives: a) prediction of the current system reliability, b) projection on the system reliability for someI future

  12. Design and control strategies for CELSS - Integrating mechanistic paradigms and biological complexities

    NASA Technical Reports Server (NTRS)

    Moore, B., III; Kaufmann, R.; Reinhold, C.

    1981-01-01

    Systems analysis and control theory consideration are given to simulations of both individual components and total systems, in order to develop a reliable control strategy for a Controlled Ecological Life Support System (CELSS) which includes complex biological components. Because of the numerous nonlinearities and tight coupling within the biological component, classical control theory may be inadequate and the statistical analysis of factorial experiments more useful. The range in control characteristics of particular species may simplify the overall task by providing an appropriate balance of stability and controllability to match species function in the overall design. The ultimate goal of this research is the coordination of biological and mechanical subsystems in order to achieve a self-supporting environment.

  13. Methods for assessing the quality of data in public health information systems: a critical review.

    PubMed

    Chen, Hong; Yu, Ping; Hailey, David; Wang, Ning

    2014-01-01

    The quality of data in public health information systems can be ensured by effective data quality assessment. In order to conduct effective data quality assessment, measurable data attributes have to be precisely defined. Then reliable and valid measurement methods for data attributes have to be used to measure each attribute. We conducted a systematic review of data quality assessment methods for public health using major databases and well-known institutional websites. 35 studies were eligible for inclusion in the study. A total of 49 attributes of data quality were identified from the literature. Completeness, accuracy and timeliness were the three most frequently assessed attributes of data quality. Most studies directly examined data values. This is complemented by exploring either data users' perception or documentation quality. However, there are limitations of current data quality assessment methods: a lack of consensus on attributes measured; inconsistent definition of the data quality attributes; a lack of mixed methods for assessing data quality; and inadequate attention to reliability and validity. Removal of these limitations is an opportunity for further improvement.

  14. Evaluation of MALDI-TOF MS (Matrix-Assisted Laser Desorption-Ionization Time-of-Flight Mass Spectrometry) for routine identification of anaerobic bacteria.

    PubMed

    Rodríguez-Sánchez, Belén; Alcalá, Luis; Marín, Mercedes; Ruiz, Adrián; Alonso, Elena; Bouza, Emilio

    2016-12-01

    Information regarding the use of MALDI-TOF MS as an alternative to conventional laboratory methods for the rapid and reliable identification of bacterial isolates is still limited. In this study, MALDI-TOF MS was evaluated on 295 anaerobic isolates previously identified by 16S rRNA gene sequencing and with biochemical tests (Rapid ID 32A system, BioMérieux). In total, 85.8% of the isolates were identified by MALDI-TOF MS at the species level vs 49.8% using the Rapid ID 32A system (p < 0.0001). None of the isolates was discordantly identified at the genus level using MALDI-TOF MS and only 9 of them could not be identified using the method. Thus, our results show that MALDI-TOF MS is a robust and reliable tool for the identification of anaerobic isolates in the microbiology laboratory. Its implementation will reduce the turnaround time for a final identification and the number of isolates that require 16S rRNA sequencing. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Research on the Fusion of Dependent Evidence Based on Rank Correlation Coefficient.

    PubMed

    Shi, Fengjian; Su, Xiaoyan; Qian, Hong; Yang, Ning; Han, Wenhua

    2017-10-16

    In order to meet the higher accuracy and system reliability requirements, the information fusion for multi-sensor systems is an increasing concern. Dempster-Shafer evidence theory (D-S theory) has been investigated for many applications in multi-sensor information fusion due to its flexibility in uncertainty modeling. However, classical evidence theory assumes that the evidence is independent of each other, which is often unrealistic. Ignoring the relationship between the evidence may lead to unreasonable fusion results, and even lead to wrong decisions. This assumption severely prevents D-S evidence theory from practical application and further development. In this paper, an innovative evidence fusion model to deal with dependent evidence based on rank correlation coefficient is proposed. The model first uses rank correlation coefficient to measure the dependence degree between different evidence. Then, total discount coefficient is obtained based on the dependence degree, which also considers the impact of the reliability of evidence. Finally, the discount evidence fusion model is presented. An example is illustrated to show the use and effectiveness of the proposed method.

  16. Research on the Fusion of Dependent Evidence Based on Rank Correlation Coefficient

    PubMed Central

    Su, Xiaoyan; Qian, Hong; Yang, Ning; Han, Wenhua

    2017-01-01

    In order to meet the higher accuracy and system reliability requirements, the information fusion for multi-sensor systems is an increasing concern. Dempster–Shafer evidence theory (D–S theory) has been investigated for many applications in multi-sensor information fusion due to its flexibility in uncertainty modeling. However, classical evidence theory assumes that the evidence is independent of each other, which is often unrealistic. Ignoring the relationship between the evidence may lead to unreasonable fusion results, and even lead to wrong decisions. This assumption severely prevents D–S evidence theory from practical application and further development. In this paper, an innovative evidence fusion model to deal with dependent evidence based on rank correlation coefficient is proposed. The model first uses rank correlation coefficient to measure the dependence degree between different evidence. Then, total discount coefficient is obtained based on the dependence degree, which also considers the impact of the reliability of evidence. Finally, the discount evidence fusion model is presented. An example is illustrated to show the use and effectiveness of the proposed method. PMID:29035341

  17. The Functional Arm Scale for Throwers (FAST)-Part II: Reliability and Validity of an Upper Extremity Region-Specific and Population-Specific Patient-Reported Outcome Scale for Throwing Athletes.

    PubMed

    Huxel Bliven, Kellie C; Snyder Valier, Alison R; Bay, R Curtis; Sauers, Eric L

    2017-04-01

    The Functional Arm Scale for Throwers (FAST) is an upper extremity (UE) region-specific and population-specific patient-reported outcome (PRO) scale developed to measure health-related quality of life in throwers with UE injuries. Stages I and II, described in a companion paper, of FAST development produced a 22-item scale and a 9-item pitcher module. Stage III of scale development, establishing reliability and validity of the FAST, is reported herein. To describe stage III of scale development: reliability and validity of the FAST. Cohort study (diagnosis); Level of evidence, 2. Data from throwing athletes collected over 5 studies were pooled to assess reliability and validity of the FAST. Reliability was estimated using FAST scores from 162 throwing athletes who were injured (n = 23) and uninjured (n = 139). Concurrent validity was estimated using FAST scores and Disabilities of the Arm, Shoulder, and Hand (DASH) and Kerlan-Jobe Orthopaedic Clinic (KJOC) scores from 106 healthy, uninjured throwing athletes. Known-groups validity was estimated using FAST scores from 557 throwing athletes who were injured (n = 142) and uninjured (n = 415). Reliability and validity were assessed using intraclass correlation coefficients (ICCs), and measurement error was assessed using standard error of measurement (SEM) and minimum detectable change (MDC). Receiver operating characteristic curves and sensitivity/specificity values were estimated for known-groups validity. Data from a separate group (n = 18) of postsurgical and nonoperative/conservative rehabilitation patients were analyzed to report responsiveness of the FAST. The FAST total, subscales, and pitcher module scores demonstrated excellent test-retest reliability (ICC, 0.91-0.98). The SEM 95 and MDC 95 for the FAST total score were 3.8 and 10.5 points, respectively. The SEM 95 and MDC 95 for the pitcher module score were 5.7 and 15.7 points, respectively. The FAST scores showed acceptable correlation with DASH (ICC, 0.49-0.82) and KJOC (ICC, 0.62-0.81) scores. The FAST total score classified 85.1% of players into the correct injury group. For predicting UE injury status, a FAST total cutoff score of 10.0 out of 100.0 was 91% sensitive and 75% specific, and a pitcher module score of 10.0 out of 100.0 was 87% sensitive and 78% specific. The FAST total score demonstrated responsiveness on several indices between intake and discharge time points. The FAST is a reliable, valid, and responsive UE region-specific and population-specific PRO scale for measuring patient-reported health care outcomes in throwing athletes with injury.

  18. The Functional Arm Scale for Throwers (FAST)—Part II: Reliability and Validity of an Upper Extremity Region-Specific and Population-Specific Patient-Reported Outcome Scale for Throwing Athletes

    PubMed Central

    Huxel Bliven, Kellie C.; Snyder Valier, Alison R.; Bay, R. Curtis; Sauers, Eric L.

    2017-01-01

    Background: The Functional Arm Scale for Throwers (FAST) is an upper extremity (UE) region-specific and population-specific patient-reported outcome (PRO) scale developed to measure health-related quality of life in throwers with UE injuries. Stages I and II, described in a companion paper, of FAST development produced a 22-item scale and a 9-item pitcher module. Stage III of scale development, establishing reliability and validity of the FAST, is reported herein. Purpose: To describe stage III of scale development: reliability and validity of the FAST. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: Data from throwing athletes collected over 5 studies were pooled to assess reliability and validity of the FAST. Reliability was estimated using FAST scores from 162 throwing athletes who were injured (n = 23) and uninjured (n = 139). Concurrent validity was estimated using FAST scores and Disabilities of the Arm, Shoulder, and Hand (DASH) and Kerlan-Jobe Orthopaedic Clinic (KJOC) scores from 106 healthy, uninjured throwing athletes. Known-groups validity was estimated using FAST scores from 557 throwing athletes who were injured (n = 142) and uninjured (n = 415). Reliability and validity were assessed using intraclass correlation coefficients (ICCs), and measurement error was assessed using standard error of measurement (SEM) and minimum detectable change (MDC). Receiver operating characteristic curves and sensitivity/specificity values were estimated for known-groups validity. Data from a separate group (n = 18) of postsurgical and nonoperative/conservative rehabilitation patients were analyzed to report responsiveness of the FAST. Results: The FAST total, subscales, and pitcher module scores demonstrated excellent test-retest reliability (ICC, 0.91-0.98). The SEM95 and MDC95 for the FAST total score were 3.8 and 10.5 points, respectively. The SEM95 and MDC95 for the pitcher module score were 5.7 and 15.7 points, respectively. The FAST scores showed acceptable correlation with DASH (ICC, 0.49-0.82) and KJOC (ICC, 0.62-0.81) scores. The FAST total score classified 85.1% of players into the correct injury group. For predicting UE injury status, a FAST total cutoff score of 10.0 out of 100.0 was 91% sensitive and 75% specific, and a pitcher module score of 10.0 out of 100.0 was 87% sensitive and 78% specific. The FAST total score demonstrated responsiveness on several indices between intake and discharge time points. Conclusion: The FAST is a reliable, valid, and responsive UE region-specific and population-specific PRO scale for measuring patient-reported health care outcomes in throwing athletes with injury. PMID:28451614

  19. Reliability and maintainability assessment factors for reliable fault-tolerant systems

    NASA Technical Reports Server (NTRS)

    Bavuso, S. J.

    1984-01-01

    A long term goal of the NASA Langley Research Center is the development of a reliability assessment methodology of sufficient power to enable the credible comparison of the stochastic attributes of one ultrareliable system design against others. This methodology, developed over a 10 year period, is a combined analytic and simulative technique. An analytic component is the Computer Aided Reliability Estimation capability, third generation, or simply CARE III. A simulative component is the Gate Logic Software Simulator capability, or GLOSS. The numerous factors that potentially have a degrading effect on system reliability and the ways in which these factors that are peculiar to highly reliable fault tolerant systems are accounted for in credible reliability assessments. Also presented are the modeling difficulties that result from their inclusion and the ways in which CARE III and GLOSS mitigate the intractability of the heretofore unworkable mathematics.

  20. Overview of RICOR's reliability theoretical analysis, accelerated life demonstration test results and verification by field data

    NASA Astrophysics Data System (ADS)

    Vainshtein, Igor; Baruch, Shlomi; Regev, Itai; Segal, Victor; Filis, Avishai; Riabzev, Sergey

    2018-05-01

    The growing demand for EO applications that work around the clock 24hr/7days a week, such as in border surveillance systems, emphasizes the need for a highly reliable cryocooler having increased operational availability and optimized system's Integrated Logistic Support (ILS). In order to meet this need, RICOR developed linear and rotary cryocoolers which achieved successfully this goal. Cryocoolers MTTF was analyzed by theoretical reliability evaluation methods, demonstrated by normal and accelerated life tests at Cryocooler level and finally verified by field data analysis derived from Cryocoolers operating at system level. The following paper reviews theoretical reliability analysis methods together with analyzing reliability test results derived from standard and accelerated life demonstration tests performed at Ricor's advanced reliability laboratory. As a summary for the work process, reliability verification data will be presented as a feedback from fielded systems.

Top